den Braver, Michiel W; Vermeulen, Nico P E; Commandeur, Jan N M
2017-03-01
Modification of cellular macromolecules by reactive drug metabolites is considered to play an important role in the initiation of tissue injury by many drugs. Detection and identification of reactive intermediates is often performed by analyzing the conjugates formed after trapping by glutathione (GSH). Although sensitivity of modern mass spectrometrical methods is extremely high, absolute quantification of GSH-conjugates is critically dependent on the availability of authentic references. Although 1 H NMR is currently the method of choice for quantification of metabolites formed biosynthetically, its intrinsically low sensitivity can be a limiting factor in quantification of GSH-conjugates which generally are formed at low levels. In the present study, a simple but sensitive and generic method for absolute quantification of GSH-conjugates is presented. The method is based on quantitative alkaline hydrolysis of GSH-conjugates and subsequent quantification of glutamic acid and glycine by HPLC after precolumn derivatization with o-phthaldialdehyde/N-acetylcysteine (OPA/NAC). Because of the lower stability of the glycine OPA/NAC-derivate, quantification of the glutamic acid OPA/NAC-derivate appeared most suitable for quantification of GSH-conjugates. The novel method was used to quantify the concentrations of GSH-conjugates of diclofenac, clozapine and acetaminophen and quantification was consistent with 1 H NMR, but with a more than 100-fold lower detection limit for absolute quantification. Copyright © 2017. Published by Elsevier B.V.
Are LOD and LOQ Reliable Parameters for Sensitivity Evaluation of Spectroscopic Methods?
Ershadi, Saba; Shayanfar, Ali
2018-03-22
The limit of detection (LOD) and the limit of quantification (LOQ) are common parameters to assess the sensitivity of analytical methods. In this study, the LOD and LOQ of previously reported terbium sensitized analysis methods were calculated by different methods, and the results were compared with sensitivity parameters [lower limit of quantification (LLOQ)] of U.S. Food and Drug Administration guidelines. The details of the calibration curve and standard deviation of blank samples of three different terbium-sensitized luminescence methods for the quantification of mycophenolic acid, enrofloxacin, and silibinin were used for the calculation of LOD and LOQ. A comparison of LOD and LOQ values calculated by various methods and LLOQ shows a considerable difference. The significant difference of the calculated LOD and LOQ with various methods and LLOQ should be considered in the sensitivity evaluation of spectroscopic methods.
Cai, Yicun; He, Yuping; Lv, Rong; Chen, Hongchao; Wang, Qiang; Pan, Liangwen
2017-01-01
Meat products often consist of meat from multiple animal species, and inaccurate food product adulteration and mislabeling can negatively affect consumers. Therefore, a cost-effective and reliable method for identification and quantification of animal species in meat products is required. In this study, we developed a duplex droplet digital PCR (dddPCR) detection and quantification system to simultaneously identify and quantify the source of meat in samples containing a mixture of beef (Bos taurus) and pork (Sus scrofa) in a single digital PCR reaction tube. Mixed meat samples of known composition were used to test the accuracy and applicability of this method. The limit of detection (LOD) and the limit of quantification (LOQ) of this detection and quantification system were also identified. We conclude that our dddPCR detection and quantification system is suitable for quality control and routine analyses of meat products.
Naveen, P.; Lingaraju, H. B.; Prasad, K. Shyam
2017-01-01
Mangiferin, a polyphenolic xanthone glycoside from Mangifera indica, is used as traditional medicine for the treatment of numerous diseases. The present study was aimed to develop and validate a reversed-phase high-performance liquid chromatography (RP-HPLC) method for the quantification of mangiferin from the bark extract of M. indica. RP-HPLC analysis was performed by isocratic elution with a low-pressure gradient using 0.1% formic acid: acetonitrile (87:13) as a mobile phase with a flow rate of 1.5 ml/min. The separation was done at 26°C using a Kinetex XB-C18 column as stationary phase and the detection wavelength at 256 nm. The proposed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification, and robustness by the International Conference on Harmonisation guidelines. In linearity, the excellent correlation coefficient more than 0.999 indicated good fitting of the curve and also good linearity. The intra- and inter-day precision showed < 1% of relative standard deviation of peak area indicated high reliability and reproducibility of the method. The recovery values at three different levels (50%, 100%, and 150%) of spiked samples were found to be 100.47, 100.89, and 100.99, respectively, and low standard deviation value < 1% shows high accuracy of the method. In robustness, the results remain unaffected by small variation in the analytical parameters, which shows the robustness of the method. Liquid chromatography–mass spectrometry analysis confirmed the presence of mangiferin with M/Z value of 421. The assay developed by HPLC method is a simple, rapid, and reliable for the determination of mangiferin from M. indica. SUMMARY The present study was intended to develop and validate an RP-HPLC method for the quantification of mangiferin from the bark extract of M. indica. The developed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification and robustness by International Conference on Harmonization guidelines. This study proved that the developed assay by HPLC method is a simple, rapid and reliable for the quantification of the mangiferin from M. indica. Abbreviations Used: M. indica: Mangifera indica, RP-HPLC: Reversed-phase high-performance liquid chromatography, M/Z: Mass to charge ratio, ICH: International conference on harmonization, % RSD: Percentage of relative standard deviation, ppm: Parts per million, LOD: Limit of detection, LOQ: Limit of quantification. PMID:28539748
Naveen, P; Lingaraju, H B; Prasad, K Shyam
2017-01-01
Mangiferin, a polyphenolic xanthone glycoside from Mangifera indica , is used as traditional medicine for the treatment of numerous diseases. The present study was aimed to develop and validate a reversed-phase high-performance liquid chromatography (RP-HPLC) method for the quantification of mangiferin from the bark extract of M. indica . RP-HPLC analysis was performed by isocratic elution with a low-pressure gradient using 0.1% formic acid: acetonitrile (87:13) as a mobile phase with a flow rate of 1.5 ml/min. The separation was done at 26°C using a Kinetex XB-C18 column as stationary phase and the detection wavelength at 256 nm. The proposed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification, and robustness by the International Conference on Harmonisation guidelines. In linearity, the excellent correlation coefficient more than 0.999 indicated good fitting of the curve and also good linearity. The intra- and inter-day precision showed < 1% of relative standard deviation of peak area indicated high reliability and reproducibility of the method. The recovery values at three different levels (50%, 100%, and 150%) of spiked samples were found to be 100.47, 100.89, and 100.99, respectively, and low standard deviation value < 1% shows high accuracy of the method. In robustness, the results remain unaffected by small variation in the analytical parameters, which shows the robustness of the method. Liquid chromatography-mass spectrometry analysis confirmed the presence of mangiferin with M/Z value of 421. The assay developed by HPLC method is a simple, rapid, and reliable for the determination of mangiferin from M. indica . The present study was intended to develop and validate an RP-HPLC method for the quantification of mangiferin from the bark extract of M. indica . The developed method was validated for linearity, precision, accuracy, limit of detection, limit of quantification and robustness by International Conference on Harmonization guidelines. This study proved that the developed assay by HPLC method is a simple, rapid and reliable for the quantification of the mangiferin from M. indica . Abbreviations Used: M. indica : Mangifera indica , RP-HPLC: Reversed-phase high-performance liquid chromatography, M/Z: Mass to charge ratio, ICH: International conference on harmonization, % RSD: Percentage of relative standard deviation, ppm: Parts per million, LOD: Limit of detection, LOQ: Limit of quantification.
Shivali, Garg; Praful, Lahorkar; Vijay, Gadgil
2012-01-01
Fourier transform infrared (FT-IR) spectroscopy is a technique widely used for detection and quantification of various chemical moieties. This paper describes the use of the FT-IR spectroscopy technique for the quantification of total lactones present in Inula racemosa and Andrographis paniculata. To validate the FT-IR spectroscopy method for quantification of total lactones in I. racemosa and A. paniculata. Dried and powdered I. racemosa roots and A. paniculata plant were extracted with ethanol and dried to remove ethanol completely. The ethanol extract was analysed in a KBr pellet by FT-IR spectroscopy. The FT-IR spectroscopy method was validated and compared with a known spectrophotometric method for quantification of lactones in A. paniculata. By FT-IR spectroscopy, the amount of total lactones was found to be 2.12 ± 0.47% (n = 3) in I. racemosa and 8.65 ± 0.51% (n = 3) in A. paniculata. The method showed comparable results with a known spectrophotometric method used for quantification of such lactones: 8.42 ± 0.36% (n = 3) in A. paniculata. Limits of detection and quantification for isoallantolactone were 1 µg and 10 µg respectively; for andrographolide they were 1.5 µg and 15 µg respectively. Recoveries were over 98%, with good intra- and interday repeatability: RSD ≤ 2%. The FT-IR spectroscopy method proved linear, accurate, precise and specific, with low limits of detection and quantification, for estimation of total lactones, and is less tedious than the UV spectrophotometric method for the compounds tested. This validated FT-IR spectroscopy method is readily applicable for the quality control of I. racemosa and A. paniculata. Copyright © 2011 John Wiley & Sons, Ltd.
Automated quantification of myocardial perfusion SPECT using simplified normal limits.
Slomka, Piotr J; Nishina, Hidetaka; Berman, Daniel S; Akincioglu, Cigdem; Abidov, Aiden; Friedman, John D; Hayes, Sean W; Germano, Guido
2005-01-01
To simplify development of normal limits for myocardial perfusion SPECT (MPS), we implemented a quantification scheme in which normal limits are derived without visual scoring of abnormal scans or optimization of regional thresholds. Normal limits were derived from same-day TI-201 rest/Tc-99m-sestamibi stress scans of male (n = 40) and female (n = 40) low-likelihood patients. Defect extent, total perfusion deficit (TPD), and regional perfusion extents were derived by comparison to normal limits in polar-map coordinates. MPS scans from 256 consecutive patients without known coronary artery disease, who underwent coronary angiography, were analyzed. The new method of quantification (TPD) was compared with our previously developed quantification system and visual scoring. The receiver operator characteristic area under the curve for detection of 50% or greater stenoses by TPD (0.88 +/- 0.02) was higher than by visual scoring (0.83 +/- 0.03) ( P = .039) or standard quantification (0.82 +/- 0.03) ( P = .004). For detection of 70% or greater stenoses, it was higher for TPD (0.89 +/- 0.02) than for standard quantification (0.85 +/- 0.02) ( P = .014). Sensitivity and specificity were 93% and 79%, respectively, for TPD; 81% and 85%, respectively, for visual scoring; and 80% and 73%, respectively, for standard quantification. The use of stress mode-specific normal limits did not improve performance. Simplified quantification achieves performance better than or equivalent to visual scoring or quantification based on per-segment visual optimization of abnormality thresholds.
NASA Astrophysics Data System (ADS)
Arnst, M.; Abello Álvarez, B.; Ponthot, J.-P.; Boman, R.
2017-11-01
This paper is concerned with the characterization and the propagation of errors associated with data limitations in polynomial-chaos-based stochastic methods for uncertainty quantification. Such an issue can arise in uncertainty quantification when only a limited amount of data is available. When the available information does not suffice to accurately determine the probability distributions that must be assigned to the uncertain variables, the Bayesian method for assigning these probability distributions becomes attractive because it allows the stochastic model to account explicitly for insufficiency of the available information. In previous work, such applications of the Bayesian method had already been implemented by using the Metropolis-Hastings and Gibbs Markov Chain Monte Carlo (MCMC) methods. In this paper, we present an alternative implementation, which uses an alternative MCMC method built around an Itô stochastic differential equation (SDE) that is ergodic for the Bayesian posterior. We draw together from the mathematics literature a number of formal properties of this Itô SDE that lend support to its use in the implementation of the Bayesian method, and we describe its discretization, including the choice of the free parameters, by using the implicit Euler method. We demonstrate the proposed methodology on a problem of uncertainty quantification in a complex nonlinear engineering application relevant to metal forming.
Piñeiro, Zulema; Cantos-Villar, Emma; Palma, Miguel; Puertas, Belen
2011-11-09
A validated HPLC method with fluorescence detection for the simultaneous quantification of hydroxytyrosol and tyrosol in red wines is described. Detection conditions for both compounds were optimized (excitation at 279 and 278 and emission at 631 and 598 nm for hydroxytyrosol and tyrosol, respectively). The validation of the analytical method was based on selectivity, linearity, robustness, detection and quantification limits, repeatability, and recovery. The detection and quantification limits in red wines were set at 0.023 and 0.076 mg L(-1) for hydroxytyrosol and at 0.007 and 0.024 mg L(-1) for tyrosol determination, respectively. Precision values, both within-day and between-day (n = 5), remained below 3% for both compounds. In addition, a fractional factorial experimental design was developed to analyze the influence of six different conditions on analysis. The final optimized HPLC-fluorescence method allowed the analysis of 30 nonpretreated Spanish red wines to evaluate their hydroxytyrosol and tyrosol contents.
Lowering the quantification limit of the QubitTM RNA HS assay using RNA spike-in.
Li, Xin; Ben-Dov, Iddo Z; Mauro, Maurizio; Williams, Zev
2015-05-06
RNA quantification is often a prerequisite for most RNA analyses such as RNA sequencing. However, the relatively low sensitivity and large sample consumption of traditional RNA quantification methods such as UV spectrophotometry and even the much more sensitive fluorescence-based RNA quantification assays, such as the Qubit™ RNA HS Assay, are often inadequate for measuring minute levels of RNA isolated from limited cell and tissue samples and biofluids. Thus, there is a pressing need for a more sensitive method to reliably and robustly detect trace levels of RNA without interference from DNA. To improve the quantification limit of the Qubit™ RNA HS Assay, we spiked-in a known quantity of RNA to achieve the minimum reading required by the assay. Samples containing trace amounts of RNA were then added to the spike-in and measured as a reading increase over RNA spike-in baseline. We determined the accuracy and precision of reading increases between 1 and 20 pg/μL as well as RNA-specificity in this range, and compared to those of RiboGreen(®), another sensitive fluorescence-based RNA quantification assay. We then applied Qubit™ Assay with RNA spike-in to quantify plasma RNA samples. RNA spike-in improved the quantification limit of the Qubit™ RNA HS Assay 5-fold, from 25 pg/μL down to 5 pg/μL while maintaining high specificity to RNA. This enabled quantification of RNA with original concentration as low as 55.6 pg/μL compared to 250 pg/μL for the standard assay and decreased sample consumption from 5 to 1 ng. Plasma RNA samples that were not measurable by the Qubit™ RNA HS Assay were measurable by our modified method. The Qubit™ RNA HS Assay with RNA spike-in is able to quantify RNA with high specificity at 5-fold lower concentration and uses 5-fold less sample quantity than the standard Qubit™ Assay.
Zhu, Haitao; Nie, Binbin; Liu, Hua; Guo, Hua; Demachi, Kazuyuki; Sekino, Masaki; Shan, Baoci
2016-05-01
Phase map cross-correlation detection and quantification may produce highlighted signal at superparamagnetic iron oxide nanoparticles, and distinguish them from other hypointensities. The method may quantify susceptibility change by performing least squares analysis between a theoretically generated magnetic field template and an experimentally scanned phase image. Because characteristic phase recognition requires the removal of phase wrap and phase background, additional steps of phase unwrapping and filtering may increase the chance of computing error and enlarge the inconsistence among algorithms. To solve problem, phase gradient cross-correlation and quantification method is developed by recognizing characteristic phase gradient pattern instead of phase image because phase gradient operation inherently includes unwrapping and filtering functions. However, few studies have mentioned the detectable limit of currently used phase gradient calculation algorithms. The limit may lead to an underestimation of large magnetic susceptibility change caused by high-concentrated iron accumulation. In this study, mathematical derivation points out the value of maximum detectable phase gradient calculated by differential chain algorithm in both spatial and Fourier domain. To break through the limit, a modified quantification method is proposed by using unwrapped forward differentiation for phase gradient generation. The method enlarges the detectable range of phase gradient measurement and avoids the underestimation of magnetic susceptibility. Simulation and phantom experiments were used to quantitatively compare different methods. In vivo application performs MRI scanning on nude mice implanted by iron-labeled human cancer cells. Results validate the limit of detectable phase gradient and the consequent susceptibility underestimation. Results also demonstrate the advantage of unwrapped forward differentiation compared with differential chain algorithms for susceptibility quantification at high-concentrated iron accumulation. Copyright © 2015 Elsevier Inc. All rights reserved.
The quantification of solute concentrations in laboratory aquifer models has been largely limited to the use of sampling ports, from which samples are collected for external analysis. One of the drawbacks to this method is that the act of sampling may disturb plume dynamics and ...
Jeong, Hyun Cheol; Hong, Hee-Do; Kim, Young-Chan; Rhee, Young Kyoung; Choi, Sang Yoon; Kim, Kyung-Tack; Kim, Sung Soo; Lee, Young-Chul; Cho, Chang-Won
2015-01-01
Background: Maltol, as a type of phenolic compounds, is produced by the browning reaction during the high-temperature treatment of ginseng. Thus, maltol can be used as a marker for the quality control of various ginseng products manufactured by high-temperature treatment including red ginseng. For the quantification of maltol in Korean ginseng products, an effective high-performance liquid chromatography-diode array detector (HPLC-DAD) method was developed. Materials and Methods: The HPLC-DAD method for maltol quantification coupled with a liquid-liquid extraction (LLE) method was developed and validated in terms of linearity, precision, and accuracy. An HPLC separation was performed on a C18 column. Results: The LLE methods and HPLC running conditions for maltol quantification were optimized. The calibration curve of the maltol exhibited good linearity (R2 = 1.00). The limit of detection value of maltol was 0.26 μg/mL, and the limit of quantification value was 0.79 μg/mL. The relative standard deviations (RSDs) of the data of the intra- and inter-day experiments were <1.27% and 0.61%, respectively. The results of the recovery test were 101.35–101.75% with an RSD value of 0.21–1.65%. The developed method was applied successfully to quantify the maltol in three ginseng products manufactured by different methods. Conclusion: The results of validation demonstrated that the proposed HPLC-DAD method was useful for the quantification of maltol in various ginseng products. PMID:26246746
Jacchia, Sara; Nardini, Elena; Savini, Christian; Petrillo, Mauro; Angers-Loustau, Alexandre; Shim, Jung-Hyun; Trijatmiko, Kurniawan; Kreysa, Joachim; Mazzara, Marco
2015-02-18
In this study, we developed, optimized, and in-house validated a real-time PCR method for the event-specific detection and quantification of Golden Rice 2, a genetically modified rice with provitamin A in the grain. We optimized and evaluated the performance of the taxon (targeting rice Phospholipase D α2 gene)- and event (targeting the 3' insert-to-plant DNA junction)-specific assays that compose the method as independent modules, using haploid genome equivalents as unit of measurement. We verified the specificity of the two real-time PCR assays and determined their dynamic range, limit of quantification, limit of detection, and robustness. We also confirmed that the taxon-specific DNA sequence is present in single copy in the rice genome and verified its stability of amplification across 132 rice varieties. A relative quantification experiment evidenced the correct performance of the two assays when used in combination.
Quantitative proteome analysis using isobaric peptide termini labeling (IPTL).
Arntzen, Magnus O; Koehler, Christian J; Treumann, Achim; Thiede, Bernd
2011-01-01
The quantitative comparison of proteome level changes across biological samples has become an essential feature in proteomics that remains challenging. We have recently introduced isobaric peptide termini labeling (IPTL), a novel strategy for isobaric quantification based on the derivatization of peptide termini with complementary isotopically labeled reagents. Unlike non-isobaric quantification methods, sample complexity at the MS level is not increased, providing improved sensitivity and protein coverage. The distinguishing feature of IPTL when comparing it to more established isobaric labeling methods (iTRAQ and TMT) is the presence of quantification signatures in all sequence-determining ions in MS/MS spectra, not only in the low mass reporter ion region. This makes IPTL a quantification method that is accessible to mass spectrometers with limited capabilities in the low mass range. Also, the presence of several quantification points in each MS/MS spectrum increases the robustness of the quantification procedure.
The quantification of solute concentrations in laboratory aquifer models has been largely limited to the use of sampling ports, from which samples are collected for external analysis. One of the drawbacks to this method is that the act of sampling may disturb plume dynamics and ...
The quantification of solute concentrations in laboratory aquifer models has been largely limited to the use of sampling ports, from which samples are collected for external analysis. One of the drawbacks to this method is that the act of sampling may disturb plume dynamics and ...
The quantification of solute concentrations in laboratory aquifer models has been largely limited to the use of sampling ports, from which samples are collected for external analysis. One of the drawbacks to this method is that the act of sampling may disturb plume dynamics and ...
Theoretical limitations of quantification for noncompetitive sandwich immunoassays.
Woolley, Christine F; Hayes, Mark A; Mahanti, Prasun; Douglass Gilman, S; Taylor, Tom
2015-11-01
Immunoassays exploit the highly selective interaction between antibodies and antigens to provide a vital method for biomolecule detection at low concentrations. Developers and practitioners of immunoassays have long known that non-specific binding often restricts immunoassay limits of quantification (LOQs). Aside from non-specific binding, most efforts by analytical chemists to reduce the LOQ for these techniques have focused on improving the signal amplification methods and minimizing the limitations of the detection system. However, with detection technology now capable of sensing single-fluorescence molecules, this approach is unlikely to lead to dramatic improvements in the future. Here, fundamental interactions based on the law of mass action are analytically connected to signal generation, replacing the four- and five-parameter fittings commercially used to approximate sigmoidal immunoassay curves and allowing quantitative consideration of non-specific binding and statistical limitations in order to understand the ultimate detection capabilities of immunoassays. The restrictions imposed on limits of quantification by instrumental noise, non-specific binding, and counting statistics are discussed based on equilibrium relations for a sandwich immunoassay. Understanding the maximal capabilities of immunoassays for each of these regimes can greatly assist in the development and evaluation of immunoassay platforms. While many studies suggest that single molecule detection is possible through immunoassay techniques, here, it is demonstrated that the fundamental limit of quantification (precision of 10 % or better) for an immunoassay is approximately 131 molecules and this limit is based on fundamental and unavoidable statistical limitations.
de Kinkelder, R; van der Veen, R L P; Verbaak, F D; Faber, D J; van Leeuwen, T G; Berendschot, T T J M
2011-01-01
Purpose Accurate assessment of the amount of macular pigment (MPOD) is necessary to investigate the role of carotenoids and their assumed protective functions. High repeatability and reliability are important to monitor patients in studies investigating the influence of diet and supplements on MPOD. We evaluated the Macuscope (Macuvision Europe Ltd., Lapworth, Solihull, UK), a recently introduced device for measuring MPOD using the technique of heterochromatic flicker photometry (HFP). We determined agreement with another HFP device (QuantifEye; MPS 9000 series: Tinsley Precision Instruments Ltd., Croydon, Essex, UK) and a fundus reflectance method. Methods The right eyes of 23 healthy subjects (mean age 33.9±15.1 years) were measured. We determined agreement with QuantifEye and correlation with a fundus reflectance method. Repeatability of QuantifEye was assessed in 20 other healthy subjects (mean age 32.1±7.3 years). Repeatability was also compared with measurements by a fundus reflectance method in 10 subjects. Results We found low agreement between test and retest measurements with Macuscope. The average difference and the limits of agreement were −0.041±0.32. We found high agreement between test and retest measurements of QuantifEye (−0.02±0.18) and the fundus reflectance method (−0.04±0.18). MPOD data obtained by Macuscope and QuantifEye showed poor agreement: −0.017±0.44. For Macuscope and the fundus reflectance method, the correlation coefficient was r=0.05 (P=0.83). A significant correlation of r=0.87 (P<0.001) was found between QuantifEye and the fundus reflectance method. Conclusions Because repeatability of Macuscope measurements was low (ie, wide limits of agreement) and MPOD values correlated poorly with the fundus reflectance method, and agreed poorly with QuantifEye, the tested Macuscope protocol seems less suitable for studying MPOD. PMID:21057522
Vu, Dai Long; Ranglová, Karolína; Hájek, Jan; Hrouzek, Pavel
2018-05-01
Quantification of selenated amino-acids currently relies on methods employing inductively coupled plasma mass spectrometry (ICP-MS). Although very accurate, these methods do not allow the simultaneous determination of standard amino-acids, hampering the comparison of the content of selenated versus non-selenated species such as methionine (Met) and selenomethionine (SeMet). This paper reports two approaches for the simultaneous quantification of Met and SeMet. In the first approach, standard enzymatic hydrolysis employing Protease XIV was applied for the preparation of samples. The second approach utilized methanesulfonic acid (MA) for the hydrolysis of samples, either in a reflux system or in a microwave oven, followed by derivatization with diethyl ethoxymethylenemalonate. The prepared samples were then analyzed by multiple reaction monitoring high performance liquid chromatography tandem mass spectrometry (MRM-HPLC-MS/MS). Both approaches provided platforms for the accurate determination of selenium/sulfur substitution rate in Met. Moreover the second approach also provided accurate simultaneous quantification of Met and SeMet with a low limit of detection, low limit of quantification and wide linearity range, comparable to the commonly used gas chromatography mass spectrometry (GC-MS) method or ICP-MS. The novel method was validated using certified reference material in conjunction with the GC-MS reference method. Copyright © 2018. Published by Elsevier B.V.
Quantitative Method for Simultaneous Analysis of Acetaminophen and 6 Metabolites.
Lammers, Laureen A; Achterbergh, Roos; Pistorius, Marcel C M; Romijn, Johannes A; Mathôt, Ron A A
2017-04-01
Hepatotoxicity after ingestion of high-dose acetaminophen [N-acetyl-para-aminophenol (APAP)] is caused by the metabolites of the drug. To gain more insight into factors influencing susceptibility to APAP hepatotoxicity, quantification of APAP and metabolites is important. A few methods have been developed to simultaneously quantify APAP and its most important metabolites. However, these methods require a comprehensive sample preparation and long run times. The aim of this study was to develop and validate a simplified, but sensitive method for the simultaneous quantification of acetaminophen, the main metabolites acetaminophen glucuronide and acetaminophen sulfate, and 4 Cytochrome P450-mediated metabolites by using liquid chromatography with mass spectrometric (LC-MS) detection. The method was developed and validated for the human plasma, and it entailed a single method for sample preparation, enabling quick processing of the samples followed by an LC-MS method with a chromatographic run time of 9 minutes. The method was validated for selectivity, linearity, accuracy, imprecision, dilution integrity, recovery, process efficiency, ionization efficiency, and carryover effect. The method showed good selectivity without matrix interferences. For all analytes, the mean process efficiency was >86%, and the mean ionization efficiency was >94%. Furthermore, the accuracy was between 90.3% and 112% for all analytes, and the within- and between-run imprecision were <20% for the lower limit of quantification and <14.3% for the middle level and upper limit of quantification. The method presented here enables the simultaneous quantification of APAP and 6 of its metabolites. It is less time consuming than previously reported methods because it requires only a single and simple method for the sample preparation followed by an LC-MS method with a short run time. Therefore, this analytical method provides a useful method for both clinical and research purposes.
Rashed-Ul Islam, S M; Jahan, Munira; Tabassum, Shahina
2015-01-01
Virological monitoring is the best predictor for the management of chronic hepatitis B virus (HBV) infections. Consequently, it is important to use the most efficient, rapid and cost-effective testing systems for HBV DNA quantification. The present study compared the performance characteristics of a one-step HBV polymerase chain reaction (PCR) vs the two-step HBV PCR method for quantification of HBV DNA from clinical samples. A total of 100 samples consisting of 85 randomly selected samples from patients with chronic hepatitis B (CHB) and 15 samples from apparently healthy individuals were enrolled in this study. Of the 85 CHB clinical samples tested, HBV DNA was detected from 81% samples by one-step PCR method with median HBV DNA viral load (VL) of 7.50 × 10 3 lU/ml. In contrast, 72% samples were detected by the two-step PCR system with median HBV DNA of 3.71 × 10 3 lU/ml. The one-step method showed strong linear correlation with two-step PCR method (r = 0.89; p < 0.0001). Both methods showed good agreement at Bland-Altman plot, with a mean difference of 0.61 log 10 IU/ml and limits of agreement of -1.82 to 3.03 log 10 IU/ml. The intra-assay and interassay coefficients of variation (CV%) of plasma samples (4-7 log 10 IU/ml) for the one-step PCR method ranged between 0.33 to 0.59 and 0.28 to 0.48 respectively, thus demonstrating a high level of concordance between the two methods. Moreover, elimination of the DNA extraction step in the one-step PCR kit allowed time-efficient and significant labor and cost savings for the quantification of HBV DNA in a resource limited setting. Rashed-Ul Islam SM, Jahan M, Tabassum S. Evaluation of a Rapid One-step Real-time PCR Method as a High-throughput Screening for Quantification of Hepatitis B Virus DNA in a Resource-limited Setting. Euroasian J Hepato-Gastroenterol 2015;5(1):11-15.
Jahan, Munira; Tabassum, Shahina
2015-01-01
Virological monitoring is the best predictor for the management of chronic hepatitis B virus (HBV) infections. Consequently, it is important to use the most efficient, rapid and cost-effective testing systems for HBV DNA quantification. The present study compared the performance characteristics of a one-step HBV polymerase chain reaction (PCR) vs the two-step HBV PCR method for quantification of HBV DNA from clinical samples. A total of 100 samples consisting of 85 randomly selected samples from patients with chronic hepatitis B (CHB) and 15 samples from apparently healthy individuals were enrolled in this study. Of the 85 CHB clinical samples tested, HBV DNA was detected from 81% samples by one-step PCR method with median HBV DNA viral load (VL) of 7.50 × 103 lU/ml. In contrast, 72% samples were detected by the two-step PCR system with median HBV DNA of 3.71 × 103 lU/ml. The one-step method showed strong linear correlation with two-step PCR method (r = 0.89; p < 0.0001). Both methods showed good agreement at Bland-Altman plot, with a mean difference of 0.61 log10 IU/ml and limits of agreement of -1.82 to 3.03 log10 IU/ml. The intra-assay and interassay coefficients of variation (CV%) of plasma samples (4-7 log10 IU/ml) for the one-step PCR method ranged between 0.33 to 0.59 and 0.28 to 0.48 respectively, thus demonstrating a high level of concordance between the two methods. Moreover, elimination of the DNA extraction step in the one-step PCR kit allowed time-efficient and significant labor and cost savings for the quantification of HBV DNA in a resource limited setting. How to cite this article Rashed-Ul Islam SM, Jahan M, Tabassum S. Evaluation of a Rapid One-step Real-time PCR Method as a High-throughput Screening for Quantification of Hepatitis B Virus DNA in a Resource-limited Setting. Euroasian J Hepato-Gastroenterol 2015;5(1):11-15. PMID:29201678
Collender, Philip A.; Kirby, Amy E.; Addiss, David G.; Freeman, Matthew C.; Remais, Justin V.
2015-01-01
Limiting the environmental transmission of soil-transmitted helminths (STH), which infect 1.5 billion people worldwide, will require sensitive, reliable, and cost effective methods to detect and quantify STH in the environment. We review the state of the art of STH quantification in soil, biosolids, water, produce, and vegetation with respect to four major methodological issues: environmental sampling; recovery of STH from environmental matrices; quantification of recovered STH; and viability assessment of STH ova. We conclude that methods for sampling and recovering STH require substantial advances to provide reliable measurements for STH control. Recent innovations in the use of automated image identification and developments in molecular genetic assays offer considerable promise for improving quantification and viability assessment. PMID:26440788
Pyschik, Marcelina; Klein-Hitpaß, Marcel; Girod, Sabrina; Winter, Martin; Nowak, Sascha
2017-02-01
In this study, an optimized method using capillary electrophoresis (CE) with a direct contactless conductivity detector (C 4 D) for a new application field is presented for the quantification of fluoride in common used lithium ion battery (LIB) electrolyte using LiPF 6 in organic carbonate solvents and in ionic liquids (ILs) after contacted to Li metal. The method development for finding the right buffer and the suitable CE conditions for the quantification of fluoride was investigated. The results of the concentration of fluoride in different LIB electrolyte samples were compared to the results from the ion-selective electrode (ISE). The relative standard deviations (RSDs) and recovery rates for fluoride were obtained with a very high accuracy in both methods. The results of the fluoride concentration in the LIB electrolytes were in very good agreement for both methods. In addition, the limit of detection (LOD) and limit of quantification (LOQ) values were determined for the CE method. The CE method has been applied also for the quantification of fluoride in ILs. In the fresh IL sample, the concentration of fluoride was under the LOD. Another sample of the IL mixed with Li metal has been investigated as well. It was possible to quantify the fluoride concentration in this sample. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Jin, Chan; Guan, Jibin; Zhang, Dong; Li, Bing; Liu, Hongzhuo; He, Zhonggui
2017-10-01
We present a technique to rapid determine taxane in blood samples by supercritical fluid chromatography together with mass spectrometry. The aim of this study was to develop a supercritical fluid chromatography with mass spectrometry method for the analysis of paclitaxel, cabazitaxel, and docetaxel in whole-blood samples of rats. Liquid-dry matrix spot extraction was selected in sample preparation procedure. Supercritical fluid chromatography separation of paclitaxel, cabazitaxel, docetaxel, and glyburide (internal standard) was accomplished within 3 min by using the gradient mobile phase consisted of methanol as the compensation solvent and carbon dioxide at a flow rate of 1.0 mL/min. The method was validated regarding specificity, the lower limit of quantification, repeatability, and reproducibility of quantification, extraction recovery, and matrix effects. The lower limit of quantification was found to be 10 ng/mL since it exhibited acceptable precision and accuracy at the corresponding level. All interday accuracies and precisions were within the accepted criteria of ±15% of the nominal value and within ±20% at the lower limit of quantification, implying that the method was reliable and reproducible. In conclusion, this method is a promising tool to support and improve preclinical or clinical pharmacokinetic studies with the taxanes anticancer drugs. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Powder X-ray diffraction method for the quantification of cocrystals in the crystallization mixture.
Padrela, Luis; de Azevedo, Edmundo Gomes; Velaga, Sitaram P
2012-08-01
The solid state purity of cocrystals critically affects their performance. Thus, it is important to accurately quantify the purity of cocrystals in the final crystallization product. The aim of this study was to develop a powder X-ray diffraction (PXRD) quantification method for investigating the purity of cocrystals. The method developed was employed to study the formation of indomethacin-saccharin (IND-SAC) cocrystals by mechanochemical methods. Pure IND-SAC cocrystals were geometrically mixed with 1:1 w/w mixture of indomethacin/saccharin in various proportions. An accurately measured amount (550 mg) of the mixture was used for the PXRD measurements. The most intense, non-overlapping, characteristic diffraction peak of IND-SAC was used to construct the calibration curve in the range 0-100% (w/w). This calibration model was validated and used to monitor the formation of IND-SAC cocrystals by liquid-assisted grinding (LAG). The IND-SAC cocrystal calibration curve showed excellent linearity (R(2) = 0.9996) over the entire concentration range, displaying limit of detection (LOD) and limit of quantification (LOQ) values of 1.23% (w/w) and 3.74% (w/w), respectively. Validation results showed excellent correlations between actual and predicted concentrations of IND-SAC cocrystals (R(2) = 0.9981). The accuracy and reliability of the PXRD quantification method depend on the methods of sample preparation and handling. The crystallinity of the IND-SAC cocrystals was higher when larger amounts of methanol were used in the LAG method. The PXRD quantification method is suitable and reliable for verifying the purity of cocrystals in the final crystallization product.
Nahar, Limon Khatun; Cordero, Rosa Elena; Nutt, David; Lingford-Hughes, Anne; Turton, Samuel; Durant, Claire; Wilson, Sue; Paterson, Sue
2016-01-01
Abstract A highly sensitive and fully validated method was developed for the quantification of baclofen in human plasma. After adjusting the pH of the plasma samples using a phosphate buffer solution (pH 4), baclofen was purified using mixed mode (C8/cation exchange) solid-phase extraction (SPE) cartridges. Endogenous water-soluble compounds and lipids were removed from the cartridges before the samples were eluted and concentrated. The samples were analyzed using triple-quadrupole liquid chromatography–tandem mass spectrometry (LC–MS-MS) with triggered dynamic multiple reaction monitoring mode for simultaneous quantification and confirmation. The assay was linear from 25 to 1,000 ng/mL (r2 > 0.999; n = 6). Intraday (n = 6) and interday (n = 15) imprecisions (% relative standard deviation) were <5%, and the average recovery was 30%. The limit of detection of the method was 5 ng/mL, and the limit of quantification was 25 ng/mL. Plasma samples from healthy male volunteers (n = 9, median age: 22) given two single oral doses of baclofen (10 and 60 mg) on nonconsecutive days were analyzed to demonstrate method applicability. PMID:26538544
Ortega, Nàdia; Macià, Alba; Romero, Maria-Paz; Trullols, Esther; Morello, Jose-Ramón; Anglès, Neus; Motilva, Maria-Jose
2009-08-26
An improved chromatographic method was developed using ultra-performance liquid chromatography-tandem mass spectrometry to identify and quantify phenolic compounds and alkaloids, theobromine and caffeine, in carob flour samples. The developed method has been validated in terms of speed, sensitivity, selectivity, peak efficiency, linearity, reproducibility, limits of detection, and limits of quantification. The chromatographic method allows the identification and quantification of 20 phenolic compounds, that is, phenolic acids, flavonoids, and their aglycone and glucoside forms, together with the determination of the alkaloids, caffeine and theobromine, at low concentration levels all in a short analysis time of less than 20 min.
Collender, Philip A; Kirby, Amy E; Addiss, David G; Freeman, Matthew C; Remais, Justin V
2015-12-01
Limiting the environmental transmission of soil-transmitted helminths (STHs), which infect 1.5 billion people worldwide, will require sensitive, reliable, and cost-effective methods to detect and quantify STHs in the environment. We review the state-of-the-art of STH quantification in soil, biosolids, water, produce, and vegetation with regard to four major methodological issues: environmental sampling; recovery of STHs from environmental matrices; quantification of recovered STHs; and viability assessment of STH ova. We conclude that methods for sampling and recovering STHs require substantial advances to provide reliable measurements for STH control. Recent innovations in the use of automated image identification and developments in molecular genetic assays offer considerable promise for improving quantification and viability assessment. Copyright © 2015 Elsevier Ltd. All rights reserved.
PCR technology for screening and quantification of genetically modified organisms (GMOs).
Holst-Jensen, Arne; Rønning, Sissel B; Løvseth, Astrid; Berdal, Knut G
2003-04-01
Although PCR technology has obvious limitations, the potentially high degree of sensitivity and specificity explains why it has been the first choice of most analytical laboratories interested in detection of genetically modified (GM) organisms (GMOs) and derived materials. Because the products that laboratories receive for analysis are often processed and refined, the quality and quantity of target analyte (e.g. protein or DNA) frequently challenges the sensitivity of any detection method. Among the currently available methods, PCR methods are generally accepted as the most sensitive and reliable methods for detection of GM-derived material in routine applications. The choice of target sequence motif is the single most important factor controlling the specificity of the PCR method. The target sequence is normally a part of the modified gene construct, for example a promoter, a terminator, a gene, or a junction between two of these elements. However, the elements may originate from wildtype organisms, they may be present in more than one GMO, and their copy number may also vary from one GMO to another. They may even be combined in a similar way in more than one GMO. Thus, the choice of method should fit the purpose. Recent developments include event-specific methods, particularly useful for identification and quantification of GM content. Thresholds for labelling are now in place in many countries including those in the European Union. The success of the labelling schemes is dependent upon the efficiency with which GM-derived material can be detected. We will present an overview of currently available PCR methods for screening and quantification of GM-derived DNA, and discuss their applicability and limitations. In addition, we will discuss some of the major challenges related to determination of the limits of detection (LOD) and quantification (LOQ), and to validation of methods.
[Detection of recombinant-DNA in foods from stacked genetically modified plants].
Sorokina, E Iu; Chernyshova, O N
2012-01-01
A quantitative real-time multiplex polymerase chain reaction method was applied to the detection and quantification of MON863 and MON810 in stacked genetically modified maize MON 810xMON 863. The limit of detection was approximately 0,1%. The accuracy of the quantification, measured as bias from the accepted value and the relative repeatability standard deviation, which measures the intra-laboratory variability, were within 25% at each GM-level. A method verification has demonstrated that the MON 863 and the MON810 methods can be equally applied in quantification of the respective events in stacked MON810xMON 863.
Arashida, Naoko; Nishimoto, Rumi; Harada, Masashi; Shimbo, Kazutaka; Yamada, Naoyuki
2017-02-15
Amino acids and their related metabolites play important roles in various physiological processes and have consequently become biomarkers for diseases. However, accurate quantification methods have only been established for major compounds, such as amino acids and a limited number of target metabolites. We previously reported a highly sensitive high-throughput method for the simultaneous quantification of amines using 3-aminopyridyl-N-succinimidyl carbamate as a derivatization reagent combined with liquid chromatography-tandem mass spectrometry (LC-MS/MS). Herein, we report the successful development of a practical and accurate LC-MS/MS method to analyze low concentrations of 40 physiological amines in 19 min. Thirty-five of these amines showed good linearity, limits of quantification, accuracy, precision, and recovery characteristics in plasma, with scheduled selected reaction monitoring acquisitions. Plasma samples from 10 healthy volunteers were evaluated using our newly developed method. The results revealed that 27 amines were detected in one of the samples, and that 24 of these compounds could be quantified. Notably, this new method successfully quantified metabolites with high accuracy across three orders of magnitude, with lowest and highest averaged concentrations of 31.7 nM (for spermine) and 18.3 μM (for α-aminobutyric acid), respectively. Copyright © 2016 Elsevier B.V. All rights reserved.
Lao, Yexing; Yang, Cuiping; Zou, Wei; Gan, Manquan; Chen, Ping; Su, Weiwei
2012-05-01
The cryptand Kryptofix 2.2.2 is used extensively as a phase-transfer reagent in the preparation of [18F]fluoride-labelled radiopharmaceuticals. However, it has considerable acute toxicity. The aim of this study was to develop and validate a method for rapid (within 1 min), specific and sensitive quantification of Kryptofix 2.2.2 at trace levels. Chromatographic separations were carried out by rapid-resolution liquid chromatography (Agilent ZORBAX SB-C18 rapid-resolution column, 2.1 × 30 mm, 3.5 μm). Tandem mass spectra were acquired using a triple quadrupole mass spectrometer equipped with an electrospray ionization interface. Quantitative mass spectrometric analysis was conducted in positive ion mode and multiple reaction monitoring mode for the m/z 377.3 → 114.1 transition for Kryptofix 2.2.2. The external standard method was used for quantification. The method met the precision and efficiency requirements for PET radiopharmaceuticals, providing satisfactory results for specificity, matrix effect, stability, linearity (0.5-100 ng/ml, r(2)=0.9975), precision (coefficient of variation < 5%), accuracy (relative error < ± 3%), sensitivity (lower limit of quantification=0.5 ng) and detection time (<1 min). Fluorodeoxyglucose (n=6) was analysed, and the Kryptofix 2.2.2 content was found to be well below the maximum permissible levels approved by the US Food and Drug Administration. The developed method has a short analysis time (<1 min) and high sensitivity (lower limit of quantification=0.5 ng/ml) and can be successfully applied to rapid quantification of Kryptofix 2.2.2 at trace levels in fluorodeoxyglucose. This method could also be applied to other [18F]fluorine-labelled radiopharmaceuticals that use Kryptofix 2.2.2 as a phase-transfer reagent.
Advances in targeted proteomics and applications to biomedical research
Shi, Tujin; Song, Ehwang; Nie, Song; Rodland, Karin D.; Liu, Tao; Qian, Wei-Jun; Smith, Richard D.
2016-01-01
Targeted proteomics technique has emerged as a powerful protein quantification tool in systems biology, biomedical research, and increasing for clinical applications. The most widely used targeted proteomics approach, selected reaction monitoring (SRM), also known as multiple reaction monitoring (MRM), can be used for quantification of cellular signaling networks and preclinical verification of candidate protein biomarkers. As an extension to our previous review on advances in SRM sensitivity herein we review recent advances in the method and technology for further enhancing SRM sensitivity (from 2012 to present), and highlighting its broad biomedical applications in human bodily fluids, tissue and cell lines. Furthermore, we also review two recently introduced targeted proteomics approaches, parallel reaction monitoring (PRM) and data-independent acquisition (DIA) with targeted data extraction on fast scanning high-resolution accurate-mass (HR/AM) instruments. Such HR/AM targeted quantification with monitoring all target product ions addresses SRM limitations effectively in specificity and multiplexing; whereas when compared to SRM, PRM and DIA are still in the infancy with a limited number of applications. Thus, for HR/AM targeted quantification we focus our discussion on method development, data processing and analysis, and its advantages and limitations in targeted proteomics. Finally, general perspectives on the potential of achieving both high sensitivity and high sample throughput for large-scale quantification of hundreds of target proteins are discussed. PMID:27302376
Advances in targeted proteomics and applications to biomedical research
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shi, Tujin; Song, Ehwang; Nie, Song
Targeted proteomics technique has emerged as a powerful protein quantification tool in systems biology, biomedical research, and increasing for clinical applications. The most widely used targeted proteomics approach, selected reaction monitoring (SRM), also known as multiple reaction monitoring (MRM), can be used for quantification of cellular signaling networks and preclinical verification of candidate protein biomarkers. As an extension to our previous review on advances in SRM sensitivity (Shi et al., Proteomics, 12, 1074–1092, 2012) herein we review recent advances in the method and technology for further enhancing SRM sensitivity (from 2012 to present), and highlighting its broad biomedical applications inmore » human bodily fluids, tissue and cell lines. Furthermore, we also review two recently introduced targeted proteomics approaches, parallel reaction monitoring (PRM) and data-independent acquisition (DIA) with targeted data extraction on fast scanning high-resolution accurate-mass (HR/AM) instruments. Such HR/AM targeted quantification with monitoring all target product ions addresses SRM limitations effectively in specificity and multiplexing; whereas when compared to SRM, PRM and DIA are still in the infancy with a limited number of applications. Thus, for HR/AM targeted quantification we focus our discussion on method development, data processing and analysis, and its advantages and limitations in targeted proteomics. Finally, general perspectives on the potential of achieving both high sensitivity and high sample throughput for large-scale quantification of hundreds of target proteins are discussed.« less
Laurie, Matthew T; Bertout, Jessica A; Taylor, Sean D; Burton, Joshua N; Shendure, Jay A; Bielas, Jason H
2013-08-01
Due to the high cost of failed runs and suboptimal data yields, quantification and determination of fragment size range are crucial steps in the library preparation process for massively parallel sequencing (or next-generation sequencing). Current library quality control methods commonly involve quantification using real-time quantitative PCR and size determination using gel or capillary electrophoresis. These methods are laborious and subject to a number of significant limitations that can make library calibration unreliable. Herein, we propose and test an alternative method for quality control of sequencing libraries using droplet digital PCR (ddPCR). By exploiting a correlation we have discovered between droplet fluorescence and amplicon size, we achieve the joint quantification and size determination of target DNA with a single ddPCR assay. We demonstrate the accuracy and precision of applying this method to the preparation of sequencing libraries.
Quantitative Proteomics via High Resolution MS Quantification: Capabilities and Limitations
Higgs, Richard E.; Butler, Jon P.; Han, Bomie; Knierman, Michael D.
2013-01-01
Recent improvements in the mass accuracy and resolution of mass spectrometers have led to renewed interest in label-free quantification using data from the primary mass spectrum (MS1) acquired from data-dependent proteomics experiments. The capacity for higher specificity quantification of peptides from samples enriched for proteins of biological interest offers distinct advantages for hypothesis generating experiments relative to immunoassay detection methods or prespecified peptide ions measured by multiple reaction monitoring (MRM) approaches. Here we describe an evaluation of different methods to post-process peptide level quantification information to support protein level inference. We characterize the methods by examining their ability to recover a known dilution of a standard protein in background matrices of varying complexity. Additionally, the MS1 quantification results are compared to a standard, targeted, MRM approach on the same samples under equivalent instrument conditions. We show the existence of multiple peptides with MS1 quantification sensitivity similar to the best MRM peptides for each of the background matrices studied. Based on these results we provide recommendations on preferred approaches to leveraging quantitative measurements of multiple peptides to improve protein level inference. PMID:23710359
Nahar, Limon Khatun; Cordero, Rosa Elena; Nutt, David; Lingford-Hughes, Anne; Turton, Samuel; Durant, Claire; Wilson, Sue; Paterson, Sue
2016-03-01
A highly sensitive and fully validated method was developed for the quantification of baclofen in human plasma. After adjusting the pH of the plasma samples using a phosphate buffer solution (pH 4), baclofen was purified using mixed mode (C8/cation exchange) solid-phase extraction (SPE) cartridges. Endogenous water-soluble compounds and lipids were removed from the cartridges before the samples were eluted and concentrated. The samples were analyzed using triple-quadrupole liquid chromatography-tandem mass spectrometry (LC-MS-MS) with triggered dynamic multiple reaction monitoring mode for simultaneous quantification and confirmation. The assay was linear from 25 to 1,000 ng/mL (r(2) > 0.999; n = 6). Intraday (n = 6) and interday (n = 15) imprecisions (% relative standard deviation) were <5%, and the average recovery was 30%. The limit of detection of the method was 5 ng/mL, and the limit of quantification was 25 ng/mL. Plasma samples from healthy male volunteers (n = 9, median age: 22) given two single oral doses of baclofen (10 and 60 mg) on nonconsecutive days were analyzed to demonstrate method applicability. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Li, Xiang; Wang, Xiuxiu; Yang, Jielin; Liu, Yueming; He, Yuping; Pan, Liangwen
2014-05-16
To date, over 150 genetically modified (GM) crops are widely cultivated. To comply with regulations developed for genetically modified organisms (GMOs), including labeling policies, many detection methods for GMO identification and quantification have been developed. To detect the entrance and exit of unauthorized GM crop events in China, we developed a novel quadruplex real-time PCR method for simultaneous detection and quantification of GM cotton events GHB119 and T304-40 in cotton-derived products (based on the 5'-flanking sequence) and the insect-resistance gene Cry2Ae. The limit of detection was 10 copies for GHB119 and Cry2Ae and 25 copies for T304-40. The limit of quantification was 25 copies for GHB119 and Cry2Ae and 50 copies for T304-40. Moreover, low bias and acceptable standard deviation and relative standard deviation values were obtained in quantification analysis of six blind samples containing different GHB119 and T304-40 ingredients. The developed quadruplex quantitative method could be used for quantitative detection of two GM cotton events (GHB119 and T304-40) and Cry2Ae gene ingredient in cotton derived products.
2014-01-01
Background To date, over 150 genetically modified (GM) crops are widely cultivated. To comply with regulations developed for genetically modified organisms (GMOs), including labeling policies, many detection methods for GMO identification and quantification have been developed. Results To detect the entrance and exit of unauthorized GM crop events in China, we developed a novel quadruplex real-time PCR method for simultaneous detection and quantification of GM cotton events GHB119 and T304-40 in cotton-derived products (based on the 5′-flanking sequence) and the insect-resistance gene Cry2Ae. The limit of detection was 10 copies for GHB119 and Cry2Ae and 25 copies for T304-40. The limit of quantification was 25 copies for GHB119 and Cry2Ae and 50 copies for T304-40. Moreover, low bias and acceptable standard deviation and relative standard deviation values were obtained in quantification analysis of six blind samples containing different GHB119 and T304-40 ingredients. Conclusions The developed quadruplex quantitative method could be used for quantitative detection of two GM cotton events (GHB119 and T304-40) and Cry2Ae gene ingredient in cotton derived products. PMID:24884946
Quantifying construction and demolition waste: An analytical review
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Zezhou; Yu, Ann T.W., E-mail: bsannyu@polyu.edu.hk; Shen, Liyin
2014-09-15
Highlights: • Prevailing C and D waste quantification methodologies are identified and compared. • One specific methodology cannot fulfill all waste quantification scenarios. • A relevance tree for appropriate quantification methodology selection is proposed. • More attentions should be paid to civil and infrastructural works. • Classified information is suggested for making an effective waste management plan. - Abstract: Quantifying construction and demolition (C and D) waste generation is regarded as a prerequisite for the implementation of successful waste management. In literature, various methods have been employed to quantify the C and D waste generation at both regional and projectmore » levels. However, an integrated review that systemically describes and analyses all the existing methods has yet to be conducted. To bridge this research gap, an analytical review is conducted. Fifty-seven papers are retrieved based on a set of rigorous procedures. The characteristics of the selected papers are classified according to the following criteria - waste generation activity, estimation level and quantification methodology. Six categories of existing C and D waste quantification methodologies are identified, including site visit method, waste generation rate method, lifetime analysis method, classification system accumulation method, variables modelling method and other particular methods. A critical comparison of the identified methods is given according to their characteristics and implementation constraints. Moreover, a decision tree is proposed for aiding the selection of the most appropriate quantification method in different scenarios. Based on the analytical review, limitations of previous studies and recommendations of potential future research directions are further suggested.« less
Gallo-Oller, Gabriel; Ordoñez, Raquel; Dotor, Javier
2018-06-01
Since its first description, Western blot has been widely used in molecular labs. It constitutes a multistep method that allows the detection and/or quantification of proteins from simple to complex protein mixtures. Western blot quantification method constitutes a critical step in order to obtain accurate and reproducible results. Due to the technical knowledge required for densitometry analysis together with the resources availability, standard office scanners are often used for the imaging acquisition of developed Western blot films. Furthermore, the use of semi-quantitative software as ImageJ (Java-based image-processing and analysis software) is clearly increasing in different scientific fields. In this work, we describe the use of office scanner coupled with the ImageJ software together with a new image background subtraction method for accurate Western blot quantification. The proposed method represents an affordable, accurate and reproducible approximation that could be used in the presence of limited resources availability. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Mallah, Muhammad Ali; Sherazi, Syed Tufail Hussain; Bhanger, Muhammad Iqbal; Mahesar, Sarfaraz Ahmed; Bajeer, Muhammad Ashraf
2015-04-01
A transmission FTIR spectroscopic method was developed for direct, inexpensive and fast quantification of paracetamol content in solid pharmaceutical formulations. In this method paracetamol content is directly analyzed without solvent extraction. KBr pellets were formulated for the acquisition of FTIR spectra in transmission mode. Two chemometric models: simple Beer's law and partial least squares employed over the spectral region of 1800-1000 cm-1 for quantification of paracetamol content had a regression coefficient of (R2) of 0.999. The limits of detection and quantification using FTIR spectroscopy were 0.005 mg g-1 and 0.018 mg g-1, respectively. Study for interference was also done to check effect of the excipients. There was no significant interference from the sample matrix. The results obviously showed the sensitivity of transmission FTIR spectroscopic method for pharmaceutical analysis. This method is green in the sense that it does not require large volumes of hazardous solvents or long run times and avoids prior sample preparation.
Srivastava, Pooja; Tiwari, Neerja; Yadav, Akhilesh K; Kumar, Vijendra; Shanker, Karuna; Verma, Ram K; Gupta, Madan M; Gupta, Anil K; Khanuja, Suman P S
2008-01-01
This paper describes a sensitive, selective, specific, robust, and validated densitometric high-performance thin-layer chromatographic (HPTLC) method for the simultaneous determination of 3 key withanolides, namely, withaferin-A, 12-deoxywithastramonolide, and withanolide-A, in Ashwagandha (Withania somnifera) plant samples. The separation was performed on aluminum-backed silica gel 60F254 HPTLC plates using dichloromethane-methanol-acetone-diethyl ether (15 + 1 + 1 + 1, v/v/v/v) as the mobile phase. The withanolides were quantified by densitometry in the reflection/absorption mode at 230 nm. Precise and accurate quantification could be performed in the linear working concentration range of 66-330 ng/band with good correlation (r2 = 0.997, 0.999, and 0.996, respectively). The method was validated for recovery, precision, accuracy, robustness, limit of detection, limit of quantitation, and specificity according to International Conference on Harmonization guidelines. Specificity of quantification was confirmed using retention factor (Rf) values, UV-Vis spectral correlation, and electrospray ionization mass spectra of marker compounds in sample tracks.
Louveau, B; Fernandez, C; Zahr, N; Sauvageon-Martre, H; Maslanka, P; Faure, P; Mourah, S; Goldwirt, L
2016-12-01
A precise and accurate high-performance liquid chromatography (HPLC) quantification method of rifampicin in human plasma was developed and validated using ultraviolet detection after an automatized solid-phase extraction. The method was validated with respect to selectivity, extraction recovery, linearity, intra- and inter-day precision, accuracy, lower limit of quantification and stability. Chromatographic separation was performed on a Chromolith RP 8 column using a mixture of 0.05 m acetate buffer pH 5.7-acetonitrile (35:65, v/v) as mobile phase. The compounds were detected at a wavelength of 335 nm with a lower limit of quantification of 0.05 mg/L in human plasma. Retention times for rifampicin and 6,7-dimethyl-2,3-di(2-pyridyl) quinoxaline used as internal standard were respectively 3.77 and 4.81 min. This robust and exact method was successfully applied in routine for therapeutic drug monitoring in patients treated with rifampicin. Copyright © 2016 John Wiley & Sons, Ltd.
Taylor, Jonathan Christopher; Fenner, John Wesley
2017-11-29
Semi-quantification methods are well established in the clinic for assisted reporting of (I123) Ioflupane images. Arguably, these are limited diagnostic tools. Recent research has demonstrated the potential for improved classification performance offered by machine learning algorithms. A direct comparison between methods is required to establish whether a move towards widespread clinical adoption of machine learning algorithms is justified. This study compared three machine learning algorithms with that of a range of semi-quantification methods, using the Parkinson's Progression Markers Initiative (PPMI) research database and a locally derived clinical database for validation. Machine learning algorithms were based on support vector machine classifiers with three different sets of features: Voxel intensities Principal components of image voxel intensities Striatal binding radios from the putamen and caudate. Semi-quantification methods were based on striatal binding ratios (SBRs) from both putamina, with and without consideration of the caudates. Normal limits for the SBRs were defined through four different methods: Minimum of age-matched controls Mean minus 1/1.5/2 standard deviations from age-matched controls Linear regression of normal patient data against age (minus 1/1.5/2 standard errors) Selection of the optimum operating point on the receiver operator characteristic curve from normal and abnormal training data Each machine learning and semi-quantification technique was evaluated with stratified, nested 10-fold cross-validation, repeated 10 times. The mean accuracy of the semi-quantitative methods for classification of local data into Parkinsonian and non-Parkinsonian groups varied from 0.78 to 0.87, contrasting with 0.89 to 0.95 for classifying PPMI data into healthy controls and Parkinson's disease groups. The machine learning algorithms gave mean accuracies between 0.88 to 0.92 and 0.95 to 0.97 for local and PPMI data respectively. Classification performance was lower for the local database than the research database for both semi-quantitative and machine learning algorithms. However, for both databases, the machine learning methods generated equal or higher mean accuracies (with lower variance) than any of the semi-quantification approaches. The gain in performance from using machine learning algorithms as compared to semi-quantification was relatively small and may be insufficient, when considered in isolation, to offer significant advantages in the clinical context.
1H NMR quantification in very dilute toxin solutions: application to anatoxin-a analysis.
Dagnino, Denise; Schripsema, Jan
2005-08-01
A complete procedure is described for the extraction, detection and quantification of anatoxin-a in biological samples. Anatoxin-a is extracted from biomass by a routine acid base extraction. The extract is analysed by GC-MS, without the need of derivatization, with a detection limit of 0.5 ng. A method was developed for the accurate quantification of anatoxin-a in the standard solution to be used for the calibration of the GC analysis. 1H NMR allowed the accurate quantification of microgram quantities of anatoxin-a. The accurate quantification of compounds in standard solutions is rarely discussed, but for compounds like anatoxin-a (toxins with prices in the range of a million dollar a gram), of which generally only milligram quantities or less are available, this factor in the quantitative analysis is certainly not trivial. The method that was developed can easily be adapted for the accurate quantification of other toxins in very dilute solutions.
Liquid Chromatography-Mass Spectrometry-based Quantitative Proteomics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xie, Fang; Liu, Tao; Qian, Weijun
2011-07-22
Liquid chromatography-mass spectrometry (LC-MS)-based quantitative proteomics has become increasingly applied for a broad range of biological applications due to growing capabilities for broad proteome coverage and good accuracy in quantification. Herein, we review the current LC-MS-based quantification methods with respect to their advantages and limitations, and highlight their potential applications.
Deegan, Emily G; Stothers, Lynn; Kavanagh, Alex; Macnab, Andrew J
2018-01-01
There remains no gold standard for quantification of voluntary pelvic floor muscle (PFM) strength, despite international guidelines that recommend PFM assessment in females with urinary incontinence (UI). Methods currently reported for quantification of skeletal muscle strength across disciplines are systematically reviewed and their relevance for clinical and academic use related to the pelvic floor are described. A systematic review via Medline, PubMed, CINHAL, and the Cochrane database using key terms for pelvic floor anatomy and function were cross referenced with skeletal muscle strength quantification from 1946 to 2016. Full text peer-reviewed articles in English having female subjects with incontinence were identified. Each study was analyzed for use of controls, type of methodology as direct or indirect measures, benefits, and limitations of the technique. A total of 1586 articles were identified of which 50 met the inclusion criteria. Nine methodologies of determining PFM strength were described including: digital palpation, perineometer, dynamometry, EMG, vaginal cones, ultrasonography, magnetic resonance imaging, urine stream interruption test, and the Colpexin pull test. Thirty-two percent lacked a control group. Technical refinements in both direct and indirect instrumentation for PFM strength measurement are allowing for sensitivity. However, the most common methods of quantification remain digital palpation and perineometry; techniques that pose limitations and yield subjective or indirect measures of muscular strength. Dynamometry has potential as an accurate and sensitive tool, but is limited by inability to assess PFM strength during dynamic movements. © 2017 Wiley Periodicals, Inc.
Targeted methods for quantitative analysis of protein glycosylation
Goldman, Radoslav; Sanda, Miloslav
2018-01-01
Quantification of proteins by LC-MS/MS-MRM has become a standard method with broad projected clinical applicability. MRM quantification of protein modifications is, however, far less utilized, especially in the case of glycoproteins. This review summarizes current methods for quantitative analysis of protein glycosylation with a focus on MRM methods. We describe advantages of this quantitative approach, analytical parameters that need to be optimized to achieve reliable measurements, and point out the limitations. Differences between major classes of N- and O-glycopeptides are described and class-specific glycopeptide assays are demonstrated. PMID:25522218
Simple detection of residual enrofloxacin in meat products using microparticles and biochips.
Ha, Mi-Sun; Chung, Myung-Sub; Bae, Dong-Ho
2016-05-01
A simple and sensitive method for detecting enrofloxacin, a major veterinary fluoroquinolone, was developed. Monoclonal antibody specific for enrofloxacin was immobilised on a chip and fluorescent dye-labelled microparticles were covalently bound to the enrofloxacin molecules. Enrofloxacin in solution competes with the microparticle-immobilised enrofloxacin (enroMPs) to bind to the antibody on the chip. The presence of enrofloxacin was verified by detecting the fluorescence of enrofloxacin-bound microparticles. Under optimum conditions, a high dynamic range was achieved at enrofloxacin concentrations ranging from 1 to 1000 μg kg(-1). The limits of detection and quantification for standard solutions were 5 and 20 μg kg(-1) respectively, which are markedly lower than the maximum residue limit. Using simple extraction methods, recoveries from fortified beef, pork and chicken samples were 43.4-62.3%. This novel method also enabled approximate quantification of enrofloxacin concentration: the enroMP signal intensity decreased with increasing enrofloxacin concentration. Because of its sensitivity, specificity, simplicity and rapidity, the method described herein will facilitate the detection and approximate quantification of enrofloxacin residues in foods in a high-throughput manner.
Pedersen, S N; Lindholst, C
1999-12-09
Extraction methods were developed for quantification of the xenoestrogens 4-tert.-octylphenol (tOP) and bisphenol A (BPA) in water and in liver and muscle tissue from the rainbow trout (Oncorhynchus mykiss). The extraction of tOP and BPA from tissue samples was carried out using microwave-assisted solvent extraction (MASE) followed by solid-phase extraction (SPE). Water samples were extracted using only SPE. For the quantification of tOP and BPA, liquid chromatography mass spectrometry (LC-MS) equipped with an atmospheric pressure chemical ionisation interface (APCI) was applied. The combined methods for tissue extraction allow the use of small sample amounts of liver or muscle (typically 1 g), low volumes of solvent (20 ml), and short extraction times (25 min). Limits of quantification of tOP in tissue samples were found to be approximately 10 ng/g in muscle and 50 ng/g in liver (both based on 1 g of fresh tissue). The corresponding values for BPA were approximately 50 ng/g in both muscle and liver tissue. In water, the limit of quantification for tOP and BPA was approximately 0.1 microg/l (based on 100 ml sample size).
Liu, Junyan; Liu, Yang; Gao, Mingxia; Zhang, Xiangmin
2012-08-01
A facile proteomic quantification method, fluorescent labeling absolute quantification (FLAQ), was developed. Instead of using MS for quantification, the FLAQ method is a chromatography-based quantification in combination with MS for identification. Multidimensional liquid chromatography (MDLC) with laser-induced fluorescence (LIF) detection with high accuracy and tandem MS system were employed for FLAQ. Several requirements should be met for fluorescent labeling in MS identification: Labeling completeness, minimum side-reactions, simple MS spectra, and no extra tandem MS fragmentations for structure elucidations. A fluorescence dye, 5-iodoacetamidofluorescein, was finally chosen to label proteins on all cysteine residues. The fluorescent dye was compatible with the process of the trypsin digestion and MALDI MS identification. Quantitative labeling was achieved with optimization of reacting conditions. A synthesized peptide and model proteins, BSA (35 cysteines), OVA (five cysteines), were used for verifying the completeness of labeling. Proteins were separated through MDLC and quantified based on fluorescent intensities, followed by MS identification. High accuracy (RSD% < 1.58) and wide linearity of quantification (1-10(5) ) were achieved by LIF detection. The limit of quantitation for the model protein was as low as 0.34 amol. Parts of proteins in human liver proteome were quantified and demonstrated using FLAQ. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Simple and rapid quantification of brominated vegetable oil in commercial soft drinks by LC–MS
Chitranshi, Priyanka; da Costa, Gonçalo Gamboa
2016-01-01
We report here a simple and rapid method for the quantification of brominated vegetable oil (BVO) in soft drinks based upon liquid chromatography–electrospray ionization mass spectrometry. Unlike previously reported methods, this novel method does not require hydrolysis, extraction or derivatization steps, but rather a simple “dilute and shoot” sample preparation. The quantification is conducted by mass spectrometry in selected ion recording mode and a single point standard addition procedure. The method was validated in the range of 5–25 μg/mL BVO, encompassing the legal limit of 15 μg/mL established by the US FDA for fruit-flavored beverages in the US market. The method was characterized by excellent intra- and inter-assay accuracy (97.3–103.4%) and very low imprecision [0.5–3.6% (RSD)]. The direct nature of the quantification, simplicity, and excellent statistical performance of this methodology constitute clear advantages in relation to previously published methods for the analysis of BVO in soft drinks. PMID:27451219
Martins, Ayrton F; Frank, Carla da S; Altissimo, Joseline; de Oliveira, Júlia A; da Silva, Daiane S; Reichert, Jaqueline F; Souza, Darliana M
2017-08-24
Statins are classified as being amongst the most prescribed agents for treating hypercholesterolaemia and preventing vascular diseases. In this study, a rapid and effective liquid chromatography method, assisted by diode array detection, was designed and validated for the simultaneous quantification of atorvastatin (ATO) and simvastatin (SIM) in hospital effluent samples. The solid phase extraction (SPE) of the analytes was optimized regarding sorbent material and pH, and the dispersive liquid-liquid microextraction (DLLME), in terms of pH, ionic strength, type and volume of extractor/dispersor solvents. The performance of both extraction procedures was evaluated in terms of linearity, quantification limits, accuracy (recovery %), precision and matrix effects for each analyte. The methods proved to be linear in the concentration range considered; the quantification limits were 0.45 µg L -1 for ATO and 0.75 µg L -1 for SIM; the matrix effect was almost absent in both methods and the average recoveries remained between 81.5-90.0%; and the RSD values were <20%. The validated methods were applied to the quantification of the statins in real samples of hospital effluent; the concentrations ranged from 18.8 µg L -1 to 35.3 µg L -1 for ATO, and from 30.3 µg L -1 to 38.5 µg L -1 for SIM. Since the calculated risk quotient was ≤192, the occurrence of ATO and SIM in hospital effluent poses a potential serious risk to human health and the aquatic ecosystem.
Wang, Tao; Liu, Tingting; Wang, Zejian; Tian, Xiwei; Yang, Yi; Guo, Meijin; Chu, Ju; Zhuang, Yingping
2016-05-01
The rapid and real-time lipid determination can provide valuable information on process regulation and optimization in the algal lipid mass production. In this study, a rapid, accurate and precise quantification method of in vivo cellular lipids of Chlorella protothecoides using low field nuclear magnetic resonance (LF-NMR) was newly developed. LF-NMR was extremely sensitive to the algal lipids with the limits of the detection (LOD) of 0.0026g and 0.32g/L in dry lipid samples and algal broth, respectively, as well as limits of quantification (LOQ) of 0.0093g and 1.18g/L. Moreover, the LF-NMR signal was specifically proportional to the cellular lipids of C. protothecoides, thus the superior regression curves existing in a wide detection range from 0.02 to 0.42g for dry lipids and from 1.12 to 8.97gL(-1) of lipid concentration for in vivo lipid quantification were obtained with all R(2) higher than 0.99, irrespective of the lipid content and fatty acids profile variations. The accuracy of this novel method was further verified to be reliable by comparing lipid quantification results to those obtained by GC-MS. And the relative standard deviation (RSD) of LF-NMR results were smaller than 2%, suggesting the precision of this method. Finally, this method was successfully used in the on-line lipid monitoring during the algal lipid fermentation processes, making it possible for better understanding of the lipid accumulation mechanism and dynamic bioprocess control. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Buongiorno, J.; Lloyd, K. G.; Shumaker, A.; Schippers, A.; Webster, G.; Weightman, A.; Turner, S.
2015-12-01
Nearly 75% of the Earth's surface is covered by marine sediment that is home to an estimated 2.9 x 1029 microbial cells. A substantial impediment to understanding the abundance and distribution of cells within marine sediment is the lack of a consistent and reliable method for their taxon-specific quantification. Catalyzed reporter fluorescent in situ hybridization (CARD-FISH) provides taxon-specific enumeration, but this process requires passing a large enzyme through cell membranes, decreasing its precision relative to general cell counts using a small DNA stain. In 2015, Yamaguchi et al. developed FISH hybridization chain reaction (FISH-HCR) as an in situ whole cell detection method for environmental microorganisms. FISH-HCR amplifies the fluorescent signal, as does CARD-FISH, but it allows for milder cell permeation methods that might prevent yield loss. To compare FISH-HCR to CARD-FISH, we examined bacteria and archaea cell counts within two sediment cores, Lille Belt (~78 meters deep) and Landsort Deep (90 meters deep), which were retrieved from the Baltic Sea Basin during IODP Expedition 347. Preliminary analysis shows that CARD-FISH counts are below the quantification limit for most depths across both cores. By contrast, quantification of cells was possible with FISH-HCR in all examined depths. When quantification with CARD-FISH was above the limit of detection, counts with FISH-HCR were up to 11 fold higher for Bacteria and 3 fold higher for Archaea from the same sediment sample. Further, FISH-HCR counts follow the trends of on board counts nicely, indicating that FISH-HCR may better reflect the cellular abundance within marine sediment than other quantification methods, including qPCR. Using FISH-HCR, we found that archaeal cell counts were on average greater than bacterial cell counts, but within the same order of magnitude.
Jiang, Lingxi; Yang, Litao; Rao, Jun; Guo, Jinchao; Wang, Shu; Liu, Jia; Lee, Seonghun; Zhang, Dabing
2010-02-01
To implement genetically modified organism (GMO) labeling regulations, an event-specific analysis method based on the junction sequence between exogenous integration and host genomic DNA has become the preferential approach for GMO identification and quantification. In this study, specific primers and TaqMan probes based on the revealed 5'-end junction sequence of GM cotton MON15985 were designed, and qualitative and quantitative polymerase chain reaction (PCR) assays were established employing the designed primers and probes. In the qualitative PCR assay, the limit of detection (LOD) was 0.5 g kg(-1) in 100 ng total cotton genomic DNA, corresponding to about 17 copies of haploid cotton genomic DNA, and the LOD and limit of quantification (LOQ) for quantitative PCR assay were 10 and 17 copies of haploid cotton genomic DNA, respectively. Furthermore, the developed quantitative PCR assays were validated in-house by five different researchers. Also, five practical samples with known GM contents were quantified using the developed PCR assay in in-house validation, and the bias between the true and quantification values ranged from 2.06% to 12.59%. This study shows that the developed qualitative and quantitative PCR methods are applicable for the identification and quantification of GM cotton MON15985 and its derivates.
Wang, Hanghang; Muehlbauer, Michael J.; O’Neal, Sara K.; Newgard, Christopher B.; Hauser, Elizabeth R.; Shah, Svati H.
2017-01-01
The field of metabolomics as applied to human disease and health is rapidly expanding. In recent efforts of metabolomics research, greater emphasis has been placed on quality control and method validation. In this study, we report an experience with quality control and a practical application of method validation. Specifically, we sought to identify and modify steps in gas chromatography-mass spectrometry (GC-MS)-based, non-targeted metabolomic profiling of human plasma that could influence metabolite identification and quantification. Our experimental design included two studies: (1) a limiting-dilution study, which investigated the effects of dilution on analyte identification and quantification; and (2) a concentration-specific study, which compared the optimal plasma extract volume established in the first study with the volume used in the current institutional protocol. We confirmed that contaminants, concentration, repeatability and intermediate precision are major factors influencing metabolite identification and quantification. In addition, we established methods for improved metabolite identification and quantification, which were summarized to provide recommendations for experimental design of GC-MS-based non-targeted profiling of human plasma. PMID:28841195
Barroso, Pedro José; Martín, Julia; Santos, Juan Luis; Aparicio, Irene; Alonso, Esteban
2018-01-01
In this work, an analytical method, based on sonication-assisted extraction, clean-up by dispersive solid-phase extraction and determination by liquid chromatography-tandem mass spectrometry, has been developed and validated for the simultaneous determination of 15 emerging pollutants in leaves from four ornamental tree species. Target compounds include perfluorinated organic compounds, plasticizers, surfactants, brominated flame retardant, and preservatives. The method was optimized using Box-Behnken statistical experimental design with response surface methodology and validated in terms of recovery, accuracy, precision, and method detection and quantification limits. Quantification of target compounds was carried out using matrix-matched calibration curves. The highest recoveries were achieved for the perfluorinated organic compounds (mean values up to 87%) and preservatives (up to 88%). The lowest recoveries were achieved for plasticizers (51%) and brominated flame retardant (63%). Method detection and quantification limits were in the ranges 0.01-0.09 ng/g dry matter (dm) and 0.02-0.30 ng/g dm, respectively, for most of the target compounds. The method was successfully applied to the determination of the target compounds on leaves from four tree species used as urban ornamental trees (Citrus aurantium, Celtis australis, Platanus hispanica, and Jacaranda mimosifolia). Graphical abstract Analytical method for the biomonitorization of emerging pollutants in outdoor air.
Muratovic, Aida Zuberovic; Hagström, Thomas; Rosén, Johan; Granelli, Kristina; Hellenäs, Karl-Erik
2015-09-11
A method that uses mass spectrometry (MS) for identification and quantification of protein toxins, staphylococcal enterotoxins A and B (SEA and SEB), in milk and shrimp is described. The analysis was performed using a tryptic peptide, from each of the toxins, as the target analyte together with the corresponding (13)C-labeled synthetic internal standard peptide. The performance of the method was evaluated by analyzing spiked samples in the quantification range 2.5-30 ng/g (R² = 0.92-0.99). The limit of quantification (LOQ) in milk and the limit of detection (LOD) in shrimp was 2.5 ng/g, for both SEA and SEB toxins. The in-house reproducibility (RSD) was 8%-30% and 5%-41% at different concentrations for milk and shrimp, respectively. The method was compared to the ELISA method, used at the EU-RL (France), for milk samples spiked with SEA at low levels, in the quantification range of 2.5 to 5 ng/g. The comparison showed good coherence for the two methods: 2.9 (MS)/1.8 (ELISA) and 3.6 (MS)/3.8 (ELISA) ng/g. The major advantage of the developed method is that it allows direct confirmation of the molecular identity and quantitative analysis of SEA and SEB at low nanogram levels using a label and antibody free approach. Therefore, this method is an important step in the development of alternatives to the immune-assay tests currently used for staphylococcal enterotoxin analysis.
Ramírez, Juan Carlos; Cura, Carolina Inés; Moreira, Otacilio da Cruz; Lages-Silva, Eliane; Juiz, Natalia; Velázquez, Elsa; Ramírez, Juan David; Alberti, Anahí; Pavia, Paula; Flores-Chávez, María Delmans; Muñoz-Calderón, Arturo; Pérez-Morales, Deyanira; Santalla, José; Guedes, Paulo Marcos da Matta; Peneau, Julie; Marcet, Paula; Padilla, Carlos; Cruz-Robles, David; Valencia, Edward; Crisante, Gladys Elena; Greif, Gonzalo; Zulantay, Inés; Costales, Jaime Alfredo; Alvarez-Martínez, Miriam; Martínez, Norma Edith; Villarroel, Rodrigo; Villarroel, Sandro; Sánchez, Zunilda; Bisio, Margarita; Parrado, Rudy; Galvão, Lúcia Maria da Cunha; da Câmara, Antonia Cláudia Jácome; Espinoza, Bertha; de Noya, Belkisyole Alarcón; Puerta, Concepción; Riarte, Adelina; Diosque, Patricio; Sosa-Estani, Sergio; Guhl, Felipe; Ribeiro, Isabela; Aznar, Christine; Britto, Constança; Yadón, Zaida Estela; Schijman, Alejandro G.
2015-01-01
An international study was performed by 26 experienced PCR laboratories from 14 countries to assess the performance of duplex quantitative real-time PCR (qPCR) strategies on the basis of TaqMan probes for detection and quantification of parasitic loads in peripheral blood samples from Chagas disease patients. Two methods were studied: Satellite DNA (SatDNA) qPCR and kinetoplastid DNA (kDNA) qPCR. Both methods included an internal amplification control. Reportable range, analytical sensitivity, limits of detection and quantification, and precision were estimated according to international guidelines. In addition, inclusivity and exclusivity were estimated with DNA from stocks representing the different Trypanosoma cruzi discrete typing units and Trypanosoma rangeli and Leishmania spp. Both methods were challenged against 156 blood samples provided by the participant laboratories, including samples from acute and chronic patients with varied clinical findings, infected by oral route or vectorial transmission. kDNA qPCR showed better analytical sensitivity than SatDNA qPCR with limits of detection of 0.23 and 0.70 parasite equivalents/mL, respectively. Analyses of clinical samples revealed a high concordance in terms of sensitivity and parasitic loads determined by both SatDNA and kDNA qPCRs. This effort is a major step toward international validation of qPCR methods for the quantification of T. cruzi DNA in human blood samples, aiming to provide an accurate surrogate biomarker for diagnosis and treatment monitoring for patients with Chagas disease. PMID:26320872
Tsukahara, Keita; Takabatake, Reona; Masubuchi, Tomoko; Futo, Satoshi; Minegishi, Yasutaka; Noguchi, Akio; Kondo, Kazunari; Nishimaki-Mogami, Tomoko; Kurashima, Takeyo; Mano, Junichi; Kitta, Kazumi
2016-01-01
A real-time PCR-based analytical method was developed for the event-specific quantification of a genetically modified (GM) soybean event, MON87701. First, a standard plasmid for MON87701 quantification was constructed. The conversion factor (C f ) required to calculate the amount of genetically modified organism (GMO) was experimentally determined for a real-time PCR instrument. The determined C f for the real-time PCR instrument was 1.24. For the evaluation of the developed method, a blind test was carried out in an inter-laboratory trial. The trueness and precision were evaluated as the bias and reproducibility of relative standard deviation (RSDr), respectively. The determined biases and the RSDr values were less than 30 and 13%, respectively, at all evaluated concentrations. The limit of quantitation of the method was 0.5%, and the developed method would thus be applicable for practical analyses for the detection and quantification of MON87701.
NASA Astrophysics Data System (ADS)
Lotfy, Hayam M.; Mohamed, Dalia; Elshahed, Mona S.
2018-01-01
In the presented work several spectrophotometric methods were performed for the quantification of canagliflozin (CGZ) and metformin hydrochloride (MTF) simultaneously in their binary mixture. Two of these methods; response correlation (RC) and advanced balance point-spectrum subtraction (ABP-SS) were developed and introduced for the first time in this work, where the latter method (ABP-SS) was performed on both the zero order and the first derivative spectra of the drugs. Besides, two recently established methods; advanced amplitude modulation (AAM) and advanced absorbance subtraction (AAS) were also accomplished. All the proposed methods were validated in accordance to the ICH guidelines, where all methods were proved to be accurate and precise. Additionally, the linearity range, limit of detection and limit of quantification were determined and the selectivity was examined through the analysis of laboratory prepared mixtures and the combined dosage form of the drugs. The proposed methods were capable of determining the two drugs in the ratio present in the pharmaceutical formulation CGZ:MTF (1:17) without the requirement of any preliminary separation, further dilution or standard spiking. The results obtained by the proposed methods were in compliance with the reported chromatographic method when compared statistically, proving the absence of any significant difference in accuracy and precision between the proposed and reported methods.
Kamal, Abid; Khan, Washim; Ahmad, Sayeed; Ahmad, F. J.; Saleem, Kishwar
2015-01-01
Objective: The present study was used to design simple, accurate and sensitive reversed phase-high-performance liquid chromatography RP-HPLC and high-performance thin-layer chromatography (HPTLC) methods for the development of quantification of khellin present in the seeds of Ammi visnaga. Materials and Methods: RP-HPLC analysis was performed on a C18 column with methanol: Water (75: 25, v/v) as a mobile phase. The HPTLC method involved densitometric evaluation of khellin after resolving it on silica gel plate using ethyl acetate: Toluene: Formic acid (5.5:4.0:0.5, v/v/v) as a mobile phase. Results: The developed HPLC and HPTLC methods were validated for precision (interday, intraday and intersystem), robustness and accuracy, limit of detection and limit of quantification. The relationship between the concentration of standard solutions and the peak response was linear in both HPLC and HPTLC methods with the concentration range of 10–80 μg/mL in HPLC and 25–1,000 ng/spot in HPTLC for khellin. The % relative standard deviation values for method precision was found to be 0.63–1.97%, 0.62–2.05% in HPLC and HPTLC for khellin respectively. Accuracy of the method was checked by recovery studies conducted at three different concentration levels and the average percentage recovery was found to be 100.53% in HPLC and 100.08% in HPTLC for khellin. Conclusions: The developed HPLC and HPTLC methods for the quantification of khellin were found simple, precise, specific, sensitive and accurate which can be used for routine analysis and quality control of A. visnaga and several formulations containing it as an ingredient. PMID:26681890
NASA Astrophysics Data System (ADS)
Ahn, Sung Hee; Hyeon, Taeghwan; Kim, Myung Soo; Moon, Jeong Hee
2017-09-01
In matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF), matrix-derived ions are routinely deflected away to avoid problems with ion detection. This, however, limits the use of a quantification method that utilizes the analyte-to-matrix ion abundance ratio. In this work, we will show that it is possible to measure this ratio by a minor instrumental modification of a simple form of MALDI-TOF. This involves detector gain switching. [Figure not available: see fulltext.
Simple and accurate quantification of BTEX in ambient air by SPME and GC-MS.
Baimatova, Nassiba; Kenessov, Bulat; Koziel, Jacek A; Carlsen, Lars; Bektassov, Marat; Demyanenko, Olga P
2016-07-01
Benzene, toluene, ethylbenzene and xylenes (BTEX) comprise one of the most ubiquitous and hazardous groups of ambient air pollutants of concern. Application of standard analytical methods for quantification of BTEX is limited by the complexity of sampling and sample preparation equipment, and budget requirements. Methods based on SPME represent simpler alternative, but still require complex calibration procedures. The objective of this research was to develop a simpler, low-budget, and accurate method for quantification of BTEX in ambient air based on SPME and GC-MS. Standard 20-mL headspace vials were used for field air sampling and calibration. To avoid challenges with obtaining and working with 'zero' air, slope factors of external standard calibration were determined using standard addition and inherently polluted lab air. For polydimethylsiloxane (PDMS) fiber, differences between the slope factors of calibration plots obtained using lab and outdoor air were below 14%. PDMS fiber provided higher precision during calibration while the use of Carboxen/PDMS fiber resulted in lower detection limits for benzene and toluene. To provide sufficient accuracy, the use of 20mL vials requires triplicate sampling and analysis. The method was successfully applied for analysis of 108 ambient air samples from Almaty, Kazakhstan. Average concentrations of benzene, toluene, ethylbenzene and o-xylene were 53, 57, 11 and 14µgm(-3), respectively. The developed method can be modified for further quantification of a wider range of volatile organic compounds in air. In addition, the new method is amenable to automation. Copyright © 2016 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gracy Elias; Earl D. Mattson; Jessica E. Little
A quantitative analytical method to determine butyramide and acetamide concentrations at the low ppb levels in geothermal waters has been developed. The analytes are concentrated in a preparation step by evaporation and analyzed using HPLC-UV. Chromatographic separation is achieved isocratically with a RP C-18 column using a 30 mM phosphate buffer solution with 5 mM heptane sulfonic acid and methanol (98:2 ratio) as the mobile phase. Absorbance is measured at 200 nm. The limit of detection (LOD) for BA and AA were 2.0 {mu}g L{sup -1} and 2.5 {mu}g L{sup -1}, respectively. The limit of quantification (LOQ) for BA andmore » AA were 5.7 {mu}g L{sup -1} and 7.7 {mu}g L{sup -1}, respectively, at the detection wavelength of 200 nm. Attaining these levels of quantification better allows these amides to be used as thermally reactive tracers in low-temperature hydrogeothermal systems.« less
Srivastava, Nishi; Srivastava, Amit; Srivastava, Sharad; Rawat, Ajay Kumar Singh; Khan, Abdul Rahman
2016-03-01
A rapid, sensitive, selective and robust quantitative densitometric high-performance thin-layer chromatographic method was developed and validated for separation and quantification of syringic acid (SYA) and kaempferol (KML) in the hydrolyzed extracts of Bergenia ciliata and Bergenia stracheyi. The separation was performed on silica gel 60F254 high-performance thin-layer chromatography plates using toluene : ethyl acetate : formic acid (5 : 4: 1, v/v/v) as the mobile phase. The quantification of SYA and KML was carried out using a densitometric reflection/absorption mode at 290 nm. A dense spot of SYA and KML appeared on the developed plate at a retention factor value of 0.61 ± 0.02 and 0.70 ± 0.01. A precise and accurate quantification was performed using linear regression analysis by plotting the peak area vs concentration 100-600 ng/band (correlation coefficient: r = 0.997, regression coefficient: R(2) = 0.996) for SYA and 100-600 ng/band (correlation coefficient: r = 0.995, regression coefficient: R(2) = 0.991) for KML. The developed method was validated in terms of accuracy, recovery and inter- and intraday study as per International Conference on Harmonisation guidelines. The limit of detection and limit of quantification of SYA and KML were determined, respectively, as 91.63, 142.26 and 277.67, 431.09 ng. The statistical data analysis showed that the method is reproducible and selective for the estimation of SYA and KML in extracts of B. ciliata and B. stracheyi. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Clais, S; Boulet, G; Van Kerckhoven, M; Lanckacker, E; Delputte, P; Maes, L; Cos, P
2015-01-01
The viable plate count (VPC) is considered as the reference method for bacterial enumeration in periodontal microbiology but shows some important limitations for anaerobic bacteria. As anaerobes such as Porphyromonas gingivalis are difficult to culture, VPC becomes time-consuming and less sensitive. Hence, efficient normalization of experimental data to bacterial cell count requires alternative rapid and reliable quantification methods. This study compared the performance of VPC with that of turbidity measurement and real-time PCR (qPCR) in an experimental context using highly concentrated bacterial suspensions. Our TaqMan-based qPCR assay for P. gingivalis 16S rRNA proved to be sensitive and specific. Turbidity measurements offer a fast method to assess P. gingivalis growth, but suffer from high variability and a limited dynamic range. VPC was very time-consuming and less repeatable than qPCR. Our study concludes that qPCR provides the most rapid and precise approach for P. gingivalis quantification. Although our data were gathered in a specific research context, we believe that our conclusions on the inferior performance of VPC and turbidity measurements in comparison to qPCR can be extended to other research and clinical settings and even to other difficult-to-culture micro-organisms. Various clinical and research settings require fast and reliable quantification of bacterial suspensions. The viable plate count method (VPC) is generally seen as 'the gold standard' for bacterial enumeration. However, VPC-based quantification of anaerobes such as Porphyromonas gingivalis is time-consuming due to their stringent growth requirements and shows poor repeatability. Comparison of VPC, turbidity measurement and TaqMan-based qPCR demonstrated that qPCR possesses important advantages regarding speed, accuracy and repeatability. © 2014 The Society for Applied Microbiology.
Occurrence of ivermectin in bovine milk from the Brazilian retail market.
Lobato, V; Rath, S; Reyes, F G R
2006-07-01
High-performance liquid chromatography (HPLC) with fluorescence detection was used for the quantification of ivermectin residues in bovine milk intended for human consumption. After liquid-liquid extraction of ivermectin and purification of the extract, the compound was derivatized with 1-methylimidazol in N,N-dimethyl formamide to form a fluorescent derivative, which was separated by HPLC, using reversed-phase C18, with methanol : water (96 : 4 v/v) mobile phase at a flow rate 0.7 ml min-1. The excitation and emission wavelengths of the fluorescence detector were adjusted at 360 and 470 nm, respectively. The linearity of the method was in the range 10-100 ng ivermectin ml-1. Based on a sample of 5.0 ml, the limit of detection and the limit of quantification for ivermectin in milk were 0.6 and 2 ng ml-1, respectively. The recovery rate varied from 76.4 to 87.2%, with an average of 77.9 +/- 3.2%, at four fortification levels. The inter-day precision of the method was 13% (n = 5). Of 168 samples analysed, 17.8% contained ivermectin above the limit of quantification. Nevertheless, none of the samples contained ivermectin above the maximum residue limit (10 ng ml-1) established by the Brazilian Ministry of Agriculture.
Sobanska, Anna W; Pyzowski, Jaroslaw
2012-01-01
Ethylhexyl triazone (ET) was separated from other sunscreens such as avobenzone, octocrylene, octyl methoxycinnamate, and diethylamino hydroxybenzoyl hexyl benzoate and from parabens by normal-phase HPTLC on silica gel 60 as stationary phase. Two mobile phases were particularly effective: (A) cyclohexane-diethyl ether 1 : 1 (v/v) and (B) cyclohexane-diethyl ether-acetone 15 : 1 : 2 (v/v/v) since apart from ET analysis they facilitated separation and quantification of other sunscreens present in the formulations. Densitometric scanning was performed at 300 nm. Calibration curves for ET were nonlinear (second-degree polynomials), with R > 0.998. For both mobile phases limits of detection (LOD) were 0.03 and limits of quantification (LOQ) 0.1 μg spot(-1). Both methods were validated.
Misra, Ankita; Shukla, Pushpendra Kumar; Kumar, Bhanu; Chand, Jai; Kushwaha, Poonam; Khalid, Md.; Singh Rawat, Ajay Kumar; Srivastava, Sharad
2017-01-01
Background: Gloriosa superba L. (Colchicaceae) is used as adjuvant therapy in gout for its potential antimitotic activity due to high colchicine(s) alkaloids. Objective: This study aimed to develop an easy, cheap, precise, and accurate high-performance thin-layer chromatographic (HPTLC) validated method for simultaneous quantification of bioactive alkaloids (colchicine and gloriosine) in G. superba L. and to identify its elite chemotype(s) from Sikkim Himalayas (India). Methods: The HPTLC chromatographic method was developed using mobile phase of chloroform: acetone: diethyl amine (5:4:1) at λmax of 350 nm. Results: Five germplasms were collected from targeted region, and on morpho-anatomical inspection, no significant variation was observed among them. Quantification data reveal that content of colchicine (Rf: 0.72) and gloriosine (Rf: 0.61) varies from 0.035%–0.150% to 0.006%–0.032% (dry wt. basis). Linearity of method was obtained in the concentration range of 100–400 ng/spot of marker(s), exhibiting regression coefficient of 0.9987 (colchicine) and 0.9983 (gloriosine) with optimum recovery of 97.79 ± 3.86 and 100.023% ± 0.01%, respectively. Limit of detection and limit of quantification were analyzed, respectively, as 6.245, 18.926 and 8.024, 24.316 (ng). Two germplasms, namely NBG-27 and NBG-26, were found to be elite chemotype of both the markers. Conclusion: The developed method is validated in terms of accuracy, recovery, and precision studies as per the ICH guidelines (2005) and can be adopted for the simultaneous quantification of colchicine and gloriosine in phytopharmaceuticals. In addition, this study is relevant to explore the chemotypic variability in metabolite content for commercial and medicinal purposes. SUMMARY An easy, cheap, precise, and accurate high performance thin layer chromatographic (HPTLC) validated method for simultaneous quantification of bioactive alkaloids (colchicine and gloriosine) in G. superba L.Five germplasms were collected from targeted region, and on morpho anatomical inspection, no significant variation was observed among themQuantification data reveal that content of colchicine (Rf: 0.72) and gloriosine (Rf: 0.61) varies from 0.035%–0.150% to 0.006%–0.032% (dry wt. basis)Two germplasms, namely NBG 27 and NBG 26, were found to be elite chemotype of both the markers. PMID:29142436
Assays for therapeutic drug monitoring of β-lactam antibiotics: A structured review.
Carlier, Mieke; Stove, Veronique; Wallis, Steven C; De Waele, Jan J; Verstraete, Alain G; Lipman, Jeffrey; Roberts, Jason A
2015-10-01
In some patient groups, including critically ill patients, the pharmacokinetics of β-lactam antibiotics may be profoundly disturbed due to pathophysiological changes in distribution and elimination. Therapeutic drug monitoring (TDM) is a strategy that may help to optimise dosing. The aim of this review was to identify and analyse the published literature on the methods used for β-lactam quantification in TDM programmes. Sixteen reports described methods for the simultaneous determination of three or more β-lactam antibiotics in plasma/serum. Measurement of these antibiotics, due to low frequency of usage relative to some other tests, is generally limited to in-house chromatographic methods coupled to ultraviolet or mass spectrometric detection. Although many published methods state they are fit for TDM, they are inconvenient because of intensive sample preparation and/or long run times. Ideally, methods used for routine TDM should have a short turnaround time (fast run-time and fast sample preparation), a low limit of quantification and a sufficiently high upper limit of quantification. The published assays included a median of 6 analytes [interquartile range (IQR) 4-10], with meropenem and piperacillin being the most frequently measured β-lactam antibiotics. The median run time was 8 min (IQR 5.9-21.3 min). There is also a growing number of methods measuring free concentrations. An assay that measures antibiotics without any sample preparation would be the next step towards real-time monitoring; no such method is currently available. Copyright © 2015 Elsevier B.V. and the International Society of Chemotherapy. All rights reserved.
Bassereau, Maud; Chaintreau, Alain; Duperrex, Stéphanie; Joulain, Daniel; Leijs, Hans; Loesing, Gerd; Owen, Neil; Sherlock, Alan; Schippa, Christine; Thorel, Pierre-Jean; Vey, Matthias
2007-01-10
The performances of the GC-MS determination of suspected allergens in fragrance concentrates have been investigated. The limit of quantification was experimentally determined (10 mg/L), and the variability was investigated for three different data treatment strategies: (1) two columns and three quantification ions; (2) two columns and one quantification ion; and (3) one column and three quantification ions. The first strategy best minimizes the risk of determination bias due to coelutions. This risk was evaluated by calculating the probability of coeluting a suspected allergen with perfume constituents exhibiting ions in common. For hydroxycitronellal, when using a two-column strategy, this may statistically occur more than once every 36 analyses for one ion or once every 144 analyses for three ions in common.
Ali, Arslan; Haq, Faraz Ul; Ul Arfeen, Qamar; Sharma, Khaga Raj; Adhikari, Achyut; Musharraf, Syed Ghulam
2017-10-01
Diabetes is a major global health problem which requires new studies for its prevention and control. Scoparia dulcis, a herbal product, is widely used for treatment of diabetes. Recent studies demonstrate coixol as a potent and nontoxic insulin secretagog from S. dulcis. This study focuses on developing two quantitative methods of coixol in S. dulcis methanol-based extracts. Quantification of coixol was performed using high-performance liquid chromatography-tandem mass spectrometry (method 1) and high-performance liquid chromatography-ultraviolet detection (method 2) with limits of detection of 0.26 and 11.6 pg/μL, respectively, and limits of quantification of 0.78 and 35.5 pg/μL, respectively. S. dulcis is rich in coixol content with values of 255.5 ± 2.1 mg/kg (method 1) and 220.4 ± 2.9 mg/kg (method 2). Excellent linearity with determination coefficients >0.999 was achieved for calibration curves from 10 to 7500 ng/mL (method 1) and from 175 to 7500 ng/mL (method 2). Good accuracy (bias < -8.6%) and precision (RSD < 8.5%) were obtained for both methods. Thus, they can be employed to analyze coixol in plant extracts and herbal formulations. Copyright © 2017 John Wiley & Sons, Ltd.
Lautié, Emmanuelle; Rasse, Catherine; Rozet, Eric; Mourgues, Claire; Vanhelleputte, Jean-Paul; Quetin-Leclercq, Joëlle
2013-02-01
The aim of this study was to find if fast microwave-assisted extraction could be an alternative to the conventional Soxhlet extraction for the quantification of rotenone in yam bean seeds by SPE and HPLC-UV. For this purpose, an experimental design was used to determine the optimal conditions of the microwave extraction. Then the values of the quantification on three accessions from two different species of yam bean seeds were compared using the two different kinds of extraction. A microwave extraction of 11 min at 55°C using methanol/dichloromethane (50:50) allowed rotenone extraction either equivalently or more efficiently than the 8-h-Soxhlet extraction method and was less sensitive to moisture content. The selectivity, precision, trueness, accuracy, and limit of quantification of the method with microwave extraction were also demonstrated. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Siebenhaar, Markus; Küllmer, Kai; Fernandes, Nuno Miguel de Barros; Hüllen, Volker; Hopf, Carsten
2015-09-01
Desorption electrospray ionization (DESI) mass spectrometry is an emerging technology for direct therapeutic drug monitoring in dried blood spots (DBS). Current DBS methods require manual application of small molecules as internal standards for absolute drug quantification. With industrial standardization in mind, we superseded the manual addition of standard and built a three-layer setup for robust quantification of salicylic acid directly from DBS. We combined a dioctyl sodium sulfosuccinate weave facilitating sample spreading with a cellulose layer for addition of isotope-labeled salicylic acid as internal standard and a filter paper for analysis of the standard-containing sample by DESI-MS. Using this setup, we developed a quantification method for salicylic acid from whole blood with a validated linear curve range from 10 to 2000 mg/L, a relative standard deviation (RSD%) ≤14%, and determination coefficients of 0.997. The limit of detection (LOD) was 8 mg/L and the lower limit of quantification (LLOQ) was 10 mg/L. Recovery rates in method verification by LC-MS/MS were 97 to 101% for blinded samples. Most importantly, a study in healthy volunteers after administration of a single dose of Aspirin provides evidence to suggest that the three-layer setup may enable individual pharmacokinetic and endpoint testing following blood collection by finger pricking by patients at home. Taken together, our data suggests that DBS-based quantification of drugs by DESI-MS on pre-manufactured three-layer cartridges may be a promising approach for future near-patient therapeutic drug monitoring.
Ulu, Sevgi Tatar
2012-01-01
A sensitive spectrofluorimetric method was developed for the determination of tizanidine in human plasma, urine and pharmaceutical preparations. The method is based on reaction of tizanidine with 1-dimethylaminonaphthalene-5-sulphonyl chloride (dansyl chloride) in an alkaline medium to form a highly fluorescent derivative that was measured at 511 nm after excitation at 383 nm. The different experimental parameters affecting the fluorescence intensity of tizanidine was carefully studied and optimized. The fluorescence-concentration plots were rectilinear over the ranges 50-500 and 20-300 ng/mL for plasma and urine, respectively, detection limits of 1.81 and 0.54 ng/mL and quantification limits of 5.43 and 1.62 ng/mL for plasma and urine, respectively. The method presents good performance in terms of linearity, detection and quantification limits, precision, accuracy and specificity. The proposed method was successfully applied for the determination of tizanidine in pharmaceutical preparations. The results obtained were compared with a reference method, using t- and F-tests. Copyright © 2011 John Wiley & Sons, Ltd.
da Silva, Claudia Pereira; Emídio, Elissandro Soares; de Marchi, Mary Rosa Rodrigues
2015-01-01
This paper describes the validation of a method consisting of solid-phase extraction followed by gas chromatography-tandem mass spectrometry for the analysis of the ultraviolet (UV) filters benzophenone-3, ethylhexyl salicylate, ethylhexyl methoxycinnamate and octocrylene. The method validation criteria included evaluation of selectivity, analytical curve, trueness, precision, limits of detection and limits of quantification. The non-weighted linear regression model has traditionally been used for calibration, but it is not necessarily the optimal model in all cases. Because the assumption of homoscedasticity was not met for the analytical data in this work, a weighted least squares linear regression was used for the calibration method. The evaluated analytical parameters were satisfactory for the analytes and showed recoveries at four fortification levels between 62% and 107%, with relative standard deviations less than 14%. The detection limits ranged from 7.6 to 24.1 ng L(-1). The proposed method was used to determine the amount of UV filters in water samples from water treatment plants in Araraquara and Jau in São Paulo, Brazil. Copyright © 2014 Elsevier B.V. All rights reserved.
Allevi, Pietro; Femia, Eti Alessandra; Costa, Maria Letizia; Cazzola, Roberta; Anastasia, Mario
2008-11-28
The present report describes a method for the quantification of N-acetyl- and N-glycolylneuraminic acids without any derivatization, using their (13)C(3)-isotopologues as internal standards and a C(18) reversed-phase column modified by decylboronic acid which allows for the first time a complete chromatographic separation between the two analytes. The method is based on high-performance liquid chromatographic coupled with electrospray ion-trap mass spectrometry. The limit of quantification of the method is 0.1mg/L (2.0ng on column) for both analytes. The calibration curves are linear for both sialic acids over the range of 0.1-80mg/L (2.0-1600ng on column) with a correlation coefficient greater than 0.997. The proposed method was applied to the quantitative determination of sialic acids released from fetuin as a model of glycoproteins.
Quantification of Neural Ethanol and Acetaldehyde Using Headspace GC-MS
Heit, Claire; Eriksson, Peter; Thompson, David C; Fritz, Kristofer S; Vasiliou, Vasilis
2016-01-01
BACKGROUND There is controversy regarding the active agent responsible for alcohol addiction. The theory that ethanol itself was the agent in alcohol drinking behavior was widely accepted until acetaldehyde was found in the brain. The importance of acetaldehyde formation in the brain role is still subject to speculation due to the lack of a method to accurately assay the acetaldehyde levels directly. A highly sensitive GC-MS method to reliably determine acetaldehyde concentration with certainty is needed to address whether neural acetaldehyde is indeed responsible for increased alcohol consumption. METHODS A headspace gas chromatograph coupled to selected ion monitoring mass spectrometry was utilized to develop a quantitative assay for acetaldehyde and ethanol. Our GC-MS approach was carried out using a Bruker Scion 436-GC SQ MS. RESULTS Our approach yields limits of detection of acetaldehyde in the nanomolar range and limits of quantification in the low micromolar range. Our linear calibration includes 5 concentrations with a least square regression greater than 0.99 for both acetaldehyde and ethanol. Tissue analyses using this method revealed the capacity to quantify ethanol and acetaldehyde in blood, brain, and liver tissue from mice. CONCLUSIONS By allowing quantification of very low concentrations, this method may be used to examine the formation of ethanol metabolites, specifically acetaldehyde, in murine brain tissue in alcohol research. PMID:27501276
Redruello, Begoña; Ladero, Victor; Cuesta, Isabel; Álvarez-Buylla, Jorge R; Martín, María Cruz; Fernández, María; Alvarez, Miguel A
2013-08-15
Derivatisation treatment with diethyl ethoxymethylenemalonate followed by ultra-HPLC allowed the simultaneous quantification of 22 amino acids, 7 biogenic amines and ammonium ions in cheese samples in under 10 min. This is the fastest elution time ever reported for such a resolution. The proposed method shows good linearity (R(2)>0.995) and sensitivity (detection limit 0.08-3.91 μM; quantification limit <13.02 μM). Intra- and inter-day repeatability ranged from 0.35% to 1.25% and from 0.85% to 5.2%, respectively. No significant effect of the cheese matrix was observed. Copyright © 2013 Elsevier Ltd. All rights reserved.
Adrait, Annie; Lebert, Dorothée; Trauchessec, Mathieu; Dupuis, Alain; Louwagie, Mathilde; Masselon, Christophe; Jaquinod, Michel; Chevalier, Benoît; Vandenesch, François; Garin, Jérôme; Bruley, Christophe; Brun, Virginie
2012-06-06
Enterotoxin A (SEA) is a staphylococcal virulence factor which is suspected to worsen septic shock prognosis. However, the presence of SEA in the blood of sepsis patients has never been demonstrated. We have developed a mass spectrometry-based assay for the targeted and absolute quantification of SEA in serum. To enhance sensitivity and specificity, we combined an immunoaffinity-based sample preparation with mass spectrometry analysis in the selected reaction monitoring (SRM) mode. Absolute quantification of SEA was performed using the PSAQ™ method (Protein Standard Absolute Quantification), which uses a full-length isotope-labeled SEA as internal standard. The lower limit of detection (LLOD) and lower limit of quantification (LLOQ) were estimated at 352pg/mL and 1057pg/mL, respectively. SEA recovery after immunocapture was determined to be 7.8±1.4%. Therefore, we assumed that less than 1femtomole of each SEA proteotypic peptide was injected on the liquid chromatography column before SRM analysis. From a 6-point titration experiment, quantification accuracy was determined to be 77% and precision at LLOQ was lower than 5%. With this sensitive PSAQ-SRM assay, we expect to contribute to decipher the pathophysiological role of SEA in severe sepsis. This article is part of a Special Issue entitled: Proteomics: The clinical link. Copyright © 2011 Elsevier B.V. All rights reserved.
Roger, B; Fernandez, X; Jeannot, V; Chahboun, J
2010-01-01
The essential oil obtained from iris rhizomes is one of the most precious raw materials for the perfume industry. Its fragrance is due to irones that are gradually formed by oxidative degradation of iridals during rhizome ageing. The development of an alternative method allowing irone quantification in iris rhizomes using HS-SPME-GC. The development of the method using HS-SPME-GC was achieved using the results obtained from a conventional method, i.e. a solid-liquid extraction (SLE) followed by irone quantification by CG. Among several calibration methods tested, internal calibration gave the best results and was the least sensitive to the matrix effect. The proposed method using HS-SPME-GC is as accurate and reproducible as the conventional one using SLE. These two methods were used to monitor and compare irone concentrations in iris rhizomes that had been stored for 6 months to 9 years. Irone quantification in iris rhizome can be achieved using HS-SPME-GC. This method can thus be used for the quality control of the iris rhizomes. It offers the advantage of combining extraction and analysis with an automated device and thus allows a large number of rhizome batches to be analysed and compared in a limited amount of time. Copyright © 2010 John Wiley & Sons, Ltd.
Patyra, Ewelina; Nebot, Carolina; Gavilán, Rosa Elvira; Cepeda, Alberto; Kwiatek, Krzysztof
2018-05-01
A new multi-compound method for the analysis of veterinary drugs, namely tiamulin, trimethoprim, tylosin, sulfadiazine and sulfamethazine was developed and validated in medicated feeds. After extraction, the samples were centrifuged, diluted in Milli-Q water, filtered and analysed by high performance liquid chromatography coupled to tandem mass spectrometry. The separation of the analytes was performed on a biphenyl column with a gradient of 0.1% formic acid in acetonitrile and 0.1% formic acid in Milli-Q water. Quantitative validation was done in accordance with the guidelines laid down in European Commission Decision 2002/657/EC. Method performances were evaluated by the following parameters: linearity (R 2 < 0.99), precision (repeatability <14% and within-laboratory reproducibility <24%), recovery (73.58-115.21%), sensitivity, limit of detection (LOD), limit of quantification (LOQ), selectivity and expanded measurement uncertainty (k. = 2). The validated method was successfully applied to the 2 medicated feeds obtained from the interlaboratory studies and feed manufactures from Spain in August 2017. In these samples, tiamulin, tylosin and sulfamethazine were detected at the concentration levels declared by the manufacturers. The developed method can therefore be successfully used to routinely control the content and homogeneity of these antibacterial substances in medicated feed. Abbreviations AAFCO - Association of American Feed Control Officials; TYL - tylosin; TIAM - tiamulin fumarate; TRIM - trimethoprim; SDZ - sulfadiazine; SMZ - sulfamethazine; UV - ultraviolet detector; FLD - fluorescence detector; HPLC - high performance liquid chromatography; MS/MS - tandem mass spectrometry; LOD - limit of detection; LOQ - limit of quantification; CV - coefficient of variation; SD - standard deviation; U - uncertainty.
Liu, Ruijuan; Wang, Mengmeng; Ding, Li
2014-10-01
Menadione (VK3), an essential fat-soluble naphthoquinone, takes very important physiological and pathological roles, but its detection and quantification is challenging. Herein, a new method was developed for quantification of VK3 in human plasma by liquid chromatography-tandem mass spectrometry (LC-MS/MS) after derivatization with 3-mercaptopropionic acid via Michael addition reaction. The derivative had been identified by the mass spectra and the derivatization conditions were optimized by considering different parameters. The method was demonstrated with high sensitivity and a low limit of quantification of 0.03 ng mL(-1) for VK3, which is about 33-fold better than that for the direct analysis of the underivatized compound. The method also had good precision and reproducibility. It was applied in the determination of basal VK3 in human plasma and a clinical pharmacokinetic study of menadiol sodium diphosphate. Furthermore, the method for the quantification of VK3 using LC-MS/MS was reported in this paper for the first time, and it will provide an important strategy for the further research on VK3 and menadione analogs. Copyright © 2014 Elsevier B.V. All rights reserved.
HPLC Quantification of astaxanthin and canthaxanthin in Salmonidae eggs.
Tzanova, Milena; Argirova, Mariana; Atanasov, Vasil
2017-04-01
Astaxanthin and canthaxanthin are naturally occurring antioxidants referred to as xanthophylls. They are used as food additives in fish farms to improve the organoleptic qualities of salmonid products and to prevent reproductive diseases. This study reports the development and single-laboratory validation of a rapid method for quantification of astaxanthin and canthaxanthin in eggs of rainbow trout (Oncorhynchus mykiss) and brook trout (Salvelinus fontinalis М.). An advantage of the proposed method is the perfect combination of selective extraction of the xanthophylls and analysis of the extract by high-performance liquid chromatography and photodiode array detection. The method validation was carried out in terms of linearity, accuracy, precision, recovery and limits of detection and quantification. The method was applied for simultaneous quantification of the two xanthophylls in eggs of rainbow trout and brook trout after their selective extraction. The results show that astaxanthin accumulations in salmonid fish eggs are larger than those of canthaxanthin. As the levels of these two xanthophylls affect fish fertility, this method can be used to improve the nutritional quality and to minimize the occurrence of the M74 syndrome in fish populations. Copyright © 2016 John Wiley & Sons, Ltd.
Analysis of eight glycols in serum using LC-ESI-MS-MS.
Imbert, Laurent; Saussereau, Elodie; Lacroix, Christian
2014-01-01
A liquid chromatography coupled with electrospray tandem mass spectrometry method was developed for the analysis of ethylene glycol, diethylene glycol, triethylene glycol, 1,4-butanediol, 1,2-butanediol, 2,3-butanediol, 1,2-propanediol and 1,3-propanediol, in serum after a Schotten-Baumann derivatization by benzoyl chloride. Usual validation parameters were tested: linearity, repeatability and intermediate precision, limits of detection and quantification, carry over and ion suppression. Limits of detection were between 0.18 and 1.1 mg/L, and limits of quantification were between 0.4 and 2.3 mg/L. Separation of isomers was possible either chromatographically or by selecting specific multiple reaction monitoring transitions. This method could be a useful tool in case of suspected intoxication with antifreeze agents, solvents, dietary supplements or some medical drug compounds. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
High-throughput quantification of hydroxyproline for determination of collagen.
Hofman, Kathleen; Hall, Bronwyn; Cleaver, Helen; Marshall, Susan
2011-10-15
An accurate and high-throughput assay for collagen is essential for collagen research and development of collagen products. Hydroxyproline is routinely assayed to provide a measurement for collagen quantification. The time required for sample preparation using acid hydrolysis and neutralization prior to assay is what limits the current method for determining hydroxyproline. This work describes the conditions of alkali hydrolysis that, when combined with the colorimetric assay defined by Woessner, provide a high-throughput, accurate method for the measurement of hydroxyproline. Copyright © 2011 Elsevier Inc. All rights reserved.
Fiorini, Dennis; Boarelli, Maria Chiara; Gabbianelli, Rosita; Ballini, Roberto; Pacetti, Deborah
2016-09-01
This study sought to develop and validate a quantitative method to analyze short chain free fatty acids (SCFAs) in rat feces by solid-phase microextraction and gas chromatography (SPME-GC) using the salt mixture ammonium sulfate and sodium dihydrogen phosphate as salting out agent. Conditioning and extraction time, linearity, limits of detection and quantification, repeatability, and recovery were evaluated. The proposed method allows quantification with improved sensitivity as compared with other methods exploiting SPME-GC. The method has been applied to analyze rat fecal samples, quantifying acetic, propionic, isobutyric, butyric, isopentanoic, pentanoic, and hexanoic acids. Copyright © 2016 Elsevier Inc. All rights reserved.
Misra, Ankita; Shukla, Pushpendra Kumar; Kumar, Bhanu; Chand, Jai; Kushwaha, Poonam; Khalid, Md; Singh Rawat, Ajay Kumar; Srivastava, Sharad
2017-10-01
Gloriosa superba L. (Colchicaceae) is used as adjuvant therapy in gout for its potential antimitotic activity due to high colchicine(s) alkaloids. This study aimed to develop an easy, cheap, precise, and accurate high-performance thin-layer chromatographic (HPTLC) validated method for simultaneous quantification of bioactive alkaloids (colchicine and gloriosine) in G. superba L. and to identify its elite chemotype(s) from Sikkim Himalayas (India). The HPTLC chromatographic method was developed using mobile phase of chloroform: acetone: diethyl amine (5:4:1) at λ max of 350 nm. Five germplasms were collected from targeted region, and on morpho-anatomical inspection, no significant variation was observed among them. Quantification data reveal that content of colchicine ( R f : 0.72) and gloriosine ( R f : 0.61) varies from 0.035%-0.150% to 0.006%-0.032% (dry wt. basis). Linearity of method was obtained in the concentration range of 100-400 ng/spot of marker(s), exhibiting regression coefficient of 0.9987 (colchicine) and 0.9983 (gloriosine) with optimum recovery of 97.79 ± 3.86 and 100.023% ± 0.01%, respectively. Limit of detection and limit of quantification were analyzed, respectively, as 6.245, 18.926 and 8.024, 24.316 (ng). Two germplasms, namely NBG-27 and NBG-26, were found to be elite chemotype of both the markers. The developed method is validated in terms of accuracy, recovery, and precision studies as per the ICH guidelines (2005) and can be adopted for the simultaneous quantification of colchicine and gloriosine in phytopharmaceuticals. In addition, this study is relevant to explore the chemotypic variability in metabolite content for commercial and medicinal purposes. An easy, cheap, precise, and accurate high performance thin layer chromatographic (HPTLC) validated method for simultaneous quantification of bioactive alkaloids (colchicine and gloriosine) in G. superba L.Five germplasms were collected from targeted region, and on morpho anatomical inspection, no significant variation was observed among themQuantification data reveal that content of colchicine (Rf: 0.72) and gloriosine (Rf: 0.61) varies from 0.035%-0.150% to 0.006%-0.032% (dry wt. basis)Two germplasms, namely NBG 27 and NBG 26, were found to be elite chemotype of both the markers.
Garballo-Rubio, A; Soto-Chinchilla, J; Moreno, A; Zafra-Gómez, A
2017-04-01
Today, food security is one of the most important global issues with food quality control and identification of contaminants in foods and beverages, being crucial for human health and safety. In this paper, a novel single-step method for the simultaneous determination of 3-monochloropropanediol (3-MCPD) and glycidyl esters in samples of winterized and non-winterized fish oil by using gas chromatography tandem mass spectrometry (GC-MS/MS) is validated. The method is based on alkaline hydrolysis of esters at room temperature, using only 3-MCPD-d5 as internal standard, and a derivatization step with phenylboronic acid (PBA) at 90°C. The use of GC-MS/MS results in a simplified sample treatment and improvement of the limits of quantification and precision of the analytical method with no need of additional concentration of the extracts. A backflush tee placed between two HP-5 MS UI columns (15m×0.25µm×0.25mm) was used in order to minimize matrix effects and peak shape degradation usually observed in routine analyses. The method was validated in winterized and non-winterized fish oil, achieving a limit of quantification of 100ngg -1 and 50ngg -1 for 3-MCPD and glycidol, respectively. Method validation was accomplished by comparing our laboratory results with results obtained by an accredited reference laboratory (SGS Germany GmbH) and by calculating the recoveries obtained in an assay with spiked samples. For glycidol quantification, a mathematical equation was developed in order to compensate for the partial conversion of 3-MCPD into glycidol. This expression involves the quantification of 3-MBPD-d5 generated during hydrolysis reaction. Copyright © 2016 Elsevier B.V. All rights reserved.
Sobanska, Anna W.; Pyzowski, Jaroslaw
2012-01-01
Ethylhexyl triazone (ET) was separated from other sunscreens such as avobenzone, octocrylene, octyl methoxycinnamate, and diethylamino hydroxybenzoyl hexyl benzoate and from parabens by normal-phase HPTLC on silica gel 60 as stationary phase. Two mobile phases were particularly effective: (A) cyclohexane-diethyl ether 1 : 1 (v/v) and (B) cyclohexane-diethyl ether-acetone 15 : 1 : 2 (v/v/v) since apart from ET analysis they facilitated separation and quantification of other sunscreens present in the formulations. Densitometric scanning was performed at 300 nm. Calibration curves for ET were nonlinear (second-degree polynomials), with R > 0.998. For both mobile phases limits of detection (LOD) were 0.03 and limits of quantification (LOQ) 0.1 μg spot−1. Both methods were validated. PMID:22629203
Jeudy, Jeremy; Salvador, Arnaud; Simon, Romain; Jaffuel, Aurore; Fonbonne, Catherine; Léonard, Jean-François; Gautier, Jean-Charles; Pasquier, Olivier; Lemoine, Jerome
2014-02-01
Targeted mass spectrometry in the so-called multiple reaction monitoring mode (MRM) is certainly a promising way for the precise, accurate, and multiplexed measurement of proteins and their genetic or posttranslationally modified isoforms. MRM carried out on a low-resolution triple quadrupole instrument faces a lack of specificity when addressing the quantification of weakly concentrated proteins. In this case, extensive sample fractionation or immunoenrichment alleviates signal contamination by interferences, but in turn decreases assay performance and throughput. Recently, MRM(3) was introduced as an alternative to MRM to improve the limit of quantification of weakly concentrated protein biomarkers. In the present work, we compare MRM and MRM(3) modes for the detection of biomarkers in plasma and urine. Calibration curves drawn with MRM and MRM(3) showed a similar range of linearity (R(2) > 0.99 for both methods) with protein concentrations above 1 μg/mL in plasma and a few nanogram per milliliter in urine. In contrast, optimized MRM(3) methods improve the limits of quantification by a factor of 2 to 4 depending on the targeted peptide. This gain arises from the additional MS(3) fragmentation step, which significantly removes or decreases interfering signals within the targeted transition channels.
Marín-Sáez, Jesús; Romero-González, Roberto; Garrido Frenich, Antonia
2017-10-06
Tropane alkaloids are a wide group of substances that comprises more than 200 compounds occurring especially in the Solanaceae family. The main aim of this study is the development of a method for the analysis of the principal tropane alkaloids as atropine, scopolamine, anisodamine, tropane, tropine, littorine, homatropine, apoatropine, aposcopolamine, scopoline, tropinone, physoperuvine, pseudotropine and cuscohygrine in cereals and related matrices. For that, a simple solid-liquid extraction was optimized and a liquid chromatographic method coupled to a single stage Exactive-Orbitrap was developed. The method was validated obtaining recoveries in the range of 60-109% (except for some compounds in soy), precision values (expressed as relative standard deviation) lower than 20% and detection and quantification limits equal to or lower than 2 and 3μg/kg respectively. Finally, the method was applied to the analysis of different types of samples as buckwheat, linseed, soy and millet, obtaining positives for anisodamine, scopolamine, atropine, littorine and tropinone in a millet flour sample above the quantification limits, whereas atropine and scopolamine were detected in a buckwheat sample, below the quantification limit. Contaminated samples with Solanaceaes seeds (Datura Stramonium and Brugmansia Arborea) were also analysed, detecting concentrations up to 693μg/kg (scopolamine) for contaminated samples with Brugmansia seeds and 1847μg/kg (atropine) when samples were contaminated with Stramonium seeds. Copyright © 2017 Elsevier B.V. All rights reserved.
Takabatake, Reona; Masubuchi, Tomoko; Futo, Satoshi; Minegishi, Yasutaka; Noguchi, Akio; Kondo, Kazunari; Teshima, Reiko; Kurashima, Takeyo; Mano, Junichi; Kitta, Kazumi
2014-01-01
A novel real-time PCR-based analytical method was developed for the event-specific quantification of a genetically modified (GM) maize event, MIR162. We first prepared a standard plasmid for MIR162 quantification. The conversion factor (Cf) required to calculate the genetically modified organism (GMO) amount was empirically determined for two real-time PCR instruments, the Applied Biosystems 7900HT (ABI7900) and the Applied Biosystems 7500 (ABI7500) for which the determined Cf values were 0.697 and 0.635, respectively. To validate the developed method, a blind test was carried out in an interlaboratory study. The trueness and precision were evaluated as the bias and reproducibility of relative standard deviation (RSDr). The determined biases were less than 25% and the RSDr values were less than 20% at all evaluated concentrations. These results suggested that the limit of quantitation of the method was 0.5%, and that the developed method would thus be suitable for practical analyses for the detection and quantification of MIR162.
Microfluidics-based digital quantitative PCR for single-cell small RNA quantification.
Yu, Tian; Tang, Chong; Zhang, Ying; Zhang, Ruirui; Yan, Wei
2017-09-01
Quantitative analyses of small RNAs at the single-cell level have been challenging because of limited sensitivity and specificity of conventional real-time quantitative PCR methods. A digital quantitative PCR (dqPCR) method for miRNA quantification has been developed, but it requires the use of proprietary stem-loop primers and only applies to miRNA quantification. Here, we report a microfluidics-based dqPCR (mdqPCR) method, which takes advantage of the Fluidigm BioMark HD system for both template partition and the subsequent high-throughput dqPCR. Our mdqPCR method demonstrated excellent sensitivity and reproducibility suitable for quantitative analyses of not only miRNAs but also all other small RNA species at the single-cell level. Using this method, we discovered that each sperm has a unique miRNA profile. © The Authors 2017. Published by Oxford University Press on behalf of Society for the Study of Reproduction. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Detection and quantification limits of the EPA Enterococcus qPCR method
The U.S. EPA will be recommending a quantitative polymerase chain reaction (qPCR) method targeting Enterococcus spp. as an option for monitoring recreational beach water quality in 2013 and has published preliminary proposed water quality criteria guidelines for the method. An im...
Chu, Jun; Li, Song-Lin; Yin, Zhi-Qi; Ye, Wen-Cai; Zhang, Qing-Wen
2012-07-01
A high performance liquid chromatography coupled with diode array detector (HPLC-DAD) method was developed for simultaneous quantification of eleven major bioactive components including six coumarins, three flavonoids and two limonoids in Fructus Citri Sarcodactylis. The analysis was performed on a Cosmosil 5 C(18)-MS-II column (4.6 mm × 250 mm, 5 μm) with water-acetonitrile gradient elution. The method was validated in terms of linearity, sensitivity, precision, stability and accuracy. It was found that the calibration curves for all analytes showed good linearity (R(2)>0.9993) within the test ranges. The overall limit of detection (LOD) and limit of quantification (LOQ) were less than 3.0 and 10.2 ng. The relative standard deviations (RSDs) for intra- and inter-day repeatability were not more than 4.99% and 4.92%, respectively. The sample was stable for at least 48 h. The spike recoveries of eleven components were 95.1-104.9%. The established method was successfully applied to determine eleven components in three samples from different locations. The results showed that the newly developed HPLC-DAD method was linear, sensitive, precise and accurate, and could be used for quality control of Fructus Citri Sarcodactylis. Copyright © 2012 Elsevier B.V. All rights reserved.
Chen, Guoqiang; Hoptroff, Michael; Fei, Xiaoqing; Su, Ya; Janssen, Hans-Gerd
2013-11-22
A sensitive and specific ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed and validated for the measurement of climbazole deposition from hair care products onto artificial skin and human scalp. Deuterated climbazole was used as the internal standard. Atmospheric pressure chemical ionization (APCI) in positive mode was applied for the detection of climbazole. For quantification, multiple reaction monitoring (MRM) transition 293.0>69.0 was monitored for climbazole, and MRM transition 296.0>225.1 for the deuterated climbazole. The linear range ran from 4 to 2000 ng mL(-1). The limit of detection (LOD) and the limit of quantification (LOQ) were 1 ng mL(-1) and 4 ng mL(-1), respectively, which enabled quantification of climbazole on artificial skin and human scalp at ppb level (corresponding to 16 ng cm(-2)). For the sampling of climbazole from human scalp the buffer scrub method using a surfactant-modified phosphate buffered saline (PBS) solution was selected based on a performance comparison of tape stripping, the buffer scrub method and solvent extraction in in vitro studies. Using this method, climbazole deposition in in vitro and in vivo studies was successfully quantified. Copyright © 2013 Elsevier B.V. All rights reserved.
Multiplex cDNA quantification method that facilitates the standardization of gene expression data
Gotoh, Osamu; Murakami, Yasufumi; Suyama, Akira
2011-01-01
Microarray-based gene expression measurement is one of the major methods for transcriptome analysis. However, current microarray data are substantially affected by microarray platforms and RNA references because of the microarray method can provide merely the relative amounts of gene expression levels. Therefore, valid comparisons of the microarray data require standardized platforms, internal and/or external controls and complicated normalizations. These requirements impose limitations on the extensive comparison of gene expression data. Here, we report an effective approach to removing the unfavorable limitations by measuring the absolute amounts of gene expression levels on common DNA microarrays. We have developed a multiplex cDNA quantification method called GEP-DEAN (Gene expression profiling by DCN-encoding-based analysis). The method was validated by using chemically synthesized DNA strands of known quantities and cDNA samples prepared from mouse liver, demonstrating that the absolute amounts of cDNA strands were successfully measured with a sensitivity of 18 zmol in a highly multiplexed manner in 7 h. PMID:21415008
NASA Technical Reports Server (NTRS)
Barth, Timothy J.
2014-01-01
This workshop presentation discusses the design and implementation of numerical methods for the quantification of statistical uncertainty, including a-posteriori error bounds, for output quantities computed using CFD methods. Hydrodynamic realizations often contain numerical error arising from finite-dimensional approximation (e.g. numerical methods using grids, basis functions, particles) and statistical uncertainty arising from incomplete information and/or statistical characterization of model parameters and random fields. The first task at hand is to derive formal error bounds for statistics given realizations containing finite-dimensional numerical error [1]. The error in computed output statistics contains contributions from both realization error and the error resulting from the calculation of statistics integrals using a numerical method. A second task is to devise computable a-posteriori error bounds by numerically approximating all terms arising in the error bound estimates. For the same reason that CFD calculations including error bounds but omitting uncertainty modeling are only of limited value, CFD calculations including uncertainty modeling but omitting error bounds are only of limited value. To gain maximum value from CFD calculations, a general software package for uncertainty quantification with quantified error bounds has been developed at NASA. The package provides implementations for a suite of numerical methods used in uncertainty quantification: Dense tensorization basis methods [3] and a subscale recovery variant [1] for non-smooth data, Sparse tensorization methods[2] utilizing node-nested hierarchies, Sampling methods[4] for high-dimensional random variable spaces.
Nitric Oxide Analyzer Quantification of Plant S-Nitrosothiols.
Hussain, Adil; Yun, Byung-Wook; Loake, Gary J
2018-01-01
Nitric oxide (NO) is a small diatomic molecule that regulates multiple physiological processes in animals, plants, and microorganisms. In animals, it is involved in vasodilation and neurotransmission and is present in exhaled breath. In plants, it regulates both plant immune function and numerous developmental programs. The high reactivity and short half-life of NO and cross-reactivity of its various derivatives make its quantification difficult. Different methods based on calorimetric, fluorometric, and chemiluminescent detection of NO and its derivatives are available, but all of them have significant limitations. Here we describe a method for the chemiluminescence-based quantification of NO using ozone-chemiluminescence technology in plants. This approach provides a sensitive, robust, and flexible approach for determining the levels of NO and its signaling products, protein S-nitrosothiols.
Laser-induced plasma characterization through self-absorption quantification
NASA Astrophysics Data System (ADS)
Hou, JiaJia; Zhang, Lei; Zhao, Yang; Yan, Xingyu; Ma, Weiguang; Dong, Lei; Yin, Wangbao; Xiao, Liantuan; Jia, Suotang
2018-07-01
A self-absorption quantification method is proposed to quantify the self-absorption degree of spectral lines, in which plasma characteristics including electron temperature, elemental concentration ratio, and absolute species number density can be deduced directly. Since there is no spectral intensity involved in the calculation, the analysis results are independent of the self-absorption effects and the additional spectral efficiency calibration is not required. In order to evaluate the practicality, the limitation for application and the precision of this method are also discussed. Experimental results of aluminum-lithium alloy prove that the proposed method is qualified to realize semi-quantitative measurements and fast plasma characteristics diagnostics.
In-vitro Equilibrium Phosphate Binding Study of Sevelamer Carbonate by UV-Vis Spectrophotometry.
Prasaja, Budi; Syabani, M Maulana; Sari, Endah; Chilmi, Uci; Cahyaningsih, Prawitasari; Kosasih, Theresia Weliana
2018-06-12
Sevelamer carbonate is a cross-linked polymeric amine; it is the active ingredient in Renvela ® tablets. US FDA provides recommendation for demonstrating bioequivalence for the development of a generic product of sevelamer carbonte using in-vitro equilibrium binding study. A simple UV-vis spectrophotometry method was developed and validated for quantification of free phosphate to determine the binding parameter constant of sevelamer. The method validation demonstrated the specificity, limit of quantification, accuracy and precision of measurements. The validated method has been successfully used to analyze samples in in-vitro equilibrium binding study for demonstrating bioequivalence. © Georg Thieme Verlag KG Stuttgart · New York.
Reiter, Rolf; Wetzel, Martin; Hamesch, Karim; Strnad, Pavel; Asbach, Patrick; Haas, Matthias; Siegmund, Britta; Trautwein, Christian; Hamm, Bernd; Klatt, Dieter; Braun, Jürgen; Sack, Ingolf; Tzschätzsch, Heiko
2018-01-01
Although it has been known for decades that patients with alpha1-antitrypsin deficiency (AATD) have an increased risk of cirrhosis and hepatocellular carcinoma, limited data exist on non-invasive imaging-based methods for assessing liver fibrosis such as magnetic resonance elastography (MRE) and acoustic radiation force impulse (ARFI) quantification, and no data exist on 2D-shear wave elastography (2D-SWE). Therefore, the purpose of this study is to evaluate and compare the applicability of different elastography methods for the assessment of AATD-related liver fibrosis. Fifteen clinically asymptomatic AATD patients (11 homozygous PiZZ, 4 heterozygous PiMZ) and 16 matched healthy volunteers were examined using MRE and ARFI quantification. Additionally, patients were examined with 2D-SWE. A high correlation is evident for the shear wave speed (SWS) determined with different elastography methods in AATD patients: 2D-SWE/MRE, ARFI quantification/2D-SWE, and ARFI quantification/MRE (R = 0.8587, 0.7425, and 0.6914, respectively; P≤0.0089). Four AATD patients with pathologically increased SWS were consistently identified with all three methods-MRE, ARFI quantification, and 2D-SWE. The high correlation and consistent identification of patients with pathologically increased SWS using MRE, ARFI quantification, and 2D-SWE suggest that elastography has the potential to become a suitable imaging tool for the assessment of AATD-related liver fibrosis. These promising results provide motivation for further investigation of non-invasive assessment of AATD-related liver fibrosis using elastography.
Li, Zhao; Liu, Yong; Wei, Qingquan; Liu, Yuanjie; Liu, Wenwen; Zhang, Xuelian; Yu, Yude
2016-01-01
Absolute, precise quantification methods expand the scope of nucleic acids research and have many practical applications. Digital polymerase chain reaction (dPCR) is a powerful method for nucleic acid detection and absolute quantification. However, it requires thermal cycling and accurate temperature control, which are difficult in resource-limited conditions. Accordingly, isothermal methods, such as recombinase polymerase amplification (RPA), are more attractive. We developed a picoliter well array (PWA) chip with 27,000 consistently sized picoliter reactions (314 pL) for isothermal DNA quantification using digital RPA (dRPA) at 39°C. Sample loading using a scraping liquid blade was simple, fast, and required small reagent volumes (i.e., <20 μL). Passivating the chip surface using a methoxy-PEG-silane agent effectively eliminated cross-contamination during dRPA. Our creative optical design enabled wide-field fluorescence imaging in situ and both end-point and real-time analyses of picoliter wells in a 6-cm(2) area. It was not necessary to use scan shooting and stitch serial small images together. Using this method, we quantified serial dilutions of a Listeria monocytogenes gDNA stock solution from 9 × 10(-1) to 4 × 10(-3) copies per well with an average error of less than 11% (N = 15). Overall dRPA-on-chip processing required less than 30 min, which was a 4-fold decrease compared to dPCR, requiring approximately 2 h. dRPA on the PWA chip provides a simple and highly sensitive method to quantify nucleic acids without thermal cycling or precise micropump/microvalve control. It has applications in fast field analysis and critical clinical diagnostics under resource-limited settings.
Li, Zhao; Liu, Yong; Wei, Qingquan; Liu, Yuanjie; Liu, Wenwen; Zhang, Xuelian; Yu, Yude
2016-01-01
Absolute, precise quantification methods expand the scope of nucleic acids research and have many practical applications. Digital polymerase chain reaction (dPCR) is a powerful method for nucleic acid detection and absolute quantification. However, it requires thermal cycling and accurate temperature control, which are difficult in resource-limited conditions. Accordingly, isothermal methods, such as recombinase polymerase amplification (RPA), are more attractive. We developed a picoliter well array (PWA) chip with 27,000 consistently sized picoliter reactions (314 pL) for isothermal DNA quantification using digital RPA (dRPA) at 39°C. Sample loading using a scraping liquid blade was simple, fast, and required small reagent volumes (i.e., <20 μL). Passivating the chip surface using a methoxy-PEG-silane agent effectively eliminated cross-contamination during dRPA. Our creative optical design enabled wide-field fluorescence imaging in situ and both end-point and real-time analyses of picoliter wells in a 6-cm2 area. It was not necessary to use scan shooting and stitch serial small images together. Using this method, we quantified serial dilutions of a Listeria monocytogenes gDNA stock solution from 9 × 10-1 to 4 × 10-3 copies per well with an average error of less than 11% (N = 15). Overall dRPA-on-chip processing required less than 30 min, which was a 4-fold decrease compared to dPCR, requiring approximately 2 h. dRPA on the PWA chip provides a simple and highly sensitive method to quantify nucleic acids without thermal cycling or precise micropump/microvalve control. It has applications in fast field analysis and critical clinical diagnostics under resource-limited settings. PMID:27074005
Rahman, Md Musfiqur; Abd El-Aty, A M; Na, Tae-Woong; Park, Joon-Seong; Kabir, Md Humayun; Chung, Hyung Suk; Lee, Han Sol; Shin, Ho-Chul; Shim, Jae-Han
2017-08-15
A simultaneous analytical method was developed for the determination of methiocarb and its metabolites, methiocarb sulfoxide and methiocarb sulfone, in five livestock products (chicken, pork, beef, table egg, and milk) using liquid chromatography-tandem mass spectrometry. Due to the rapid degradation of methiocarb and its metabolites, a quick sample preparation method was developed using acetonitrile and salts followed by purification via dispersive- solid phase extraction (d-SPE). Seven-point calibration curves were constructed separately in each matrix, and good linearity was observed in each matrix-matched calibration curve with a coefficient of determination (R 2 ) ≥ 0.991. The limits of detection and quantification were 0.0016 and 0.005mg/kg, respectively, for all tested analytes in various matrices. The method was validated in triplicate at three fortification levels (equivalent to 1, 2, and 10 times the limit of quantification) with a recovery rate ranging between 76.4-118.0% and a relative standard deviation≤10.0%. The developed method was successfully applied to market samples, and no residues of methiocarb and/or its metabolites were observed in the tested samples. In sum, this method can be applied for the routine analysis of methiocarb and its metabolites in foods of animal origins. Copyright © 2017 Elsevier B.V. All rights reserved.
Quantification of taurine in energy drinks using ¹H NMR.
Hohmann, Monika; Felbinger, Christine; Christoph, Norbert; Wachter, Helmut; Wiest, Johannes; Holzgrabe, Ulrike
2014-05-01
The consumption of so called energy drinks is increasing, especially among adolescents. These beverages commonly contain considerable amounts of the amino sulfonic acid taurine, which is related to a magnitude of various physiological effects. The customary method to control the legal limit of taurine in energy drinks is LC-UV/vis with postcolumn derivatization using ninhydrin. In this paper we describe the quantification of taurine in energy drinks by (1)H NMR as an alternative to existing methods of quantification. Variation of pH values revealed the separation of a distinct taurine signal in (1)H NMR spectra, which was applied for integration and quantification. Quantification was performed using external calibration (R(2)>0.9999; linearity verified by Mandel's fitting test with a 95% confidence level) and PULCON. Taurine concentrations in 20 different energy drinks were analyzed by both using (1)H NMR and LC-UV/vis. The deviation between (1)H NMR and LC-UV/vis results was always below the expanded measurement uncertainty of 12.2% for the LC-UV/vis method (95% confidence level) and at worst 10.4%. Due to the high accordance to LC-UV/vis data and adequate recovery rates (ranging between 97.1% and 108.2%), (1)H NMR measurement presents a suitable method to quantify taurine in energy drinks. Copyright © 2013 Elsevier B.V. All rights reserved.
Louwagie, Mathilde; Kieffer-Jaquinod, Sylvie; Dupierris, Véronique; Couté, Yohann; Bruley, Christophe; Garin, Jérôme; Dupuis, Alain; Jaquinod, Michel; Brun, Virginie
2012-07-06
Accurate quantification of pure peptides and proteins is essential for biotechnology, clinical chemistry, proteomics, and systems biology. The reference method to quantify peptides and proteins is amino acid analysis (AAA). This consists of an acidic hydrolysis followed by chromatographic separation and spectrophotometric detection of amino acids. Although widely used, this method displays some limitations, in particular the need for large amounts of starting material. Driven by the need to quantify isotope-dilution standards used for absolute quantitative proteomics, particularly stable isotope-labeled (SIL) peptides and PSAQ proteins, we developed a new AAA assay (AAA-MS). This method requires neither derivatization nor chromatographic separation of amino acids. It is based on rapid microwave-assisted acidic hydrolysis followed by high-resolution mass spectrometry analysis of amino acids. Quantification is performed by comparing MS signals from labeled amino acids (SIL peptide- and PSAQ-derived) with those of unlabeled amino acids originating from co-hydrolyzed NIST standard reference materials. For both SIL peptides and PSAQ standards, AAA-MS quantification results were consistent with classical AAA measurements. Compared to AAA assay, AAA-MS was much faster and was 100-fold more sensitive for peptide and protein quantification. Finally, thanks to the development of a labeled protein standard, we also extended AAA-MS analysis to the quantification of unlabeled proteins.
Faizan, Mohammad; Esatbeyoglu, Tuba; Bayram, Banu; Rimbach, Gerald
2014-04-01
Malondialdehyde (MDA) is a biomarker of lipid peroxidation and is present in foods and biological samples such as plasma. A high-performance liquid chromatography (HPLC) method was applied to determine MDA in fish liver samples after derivatization with 2,4-dinitrophenylhydrazine (DNPH) using a ODS2 column (10 cm × 4.6 mm, 3 μm) and a photodiode array detector. The mobile phase consisted of 0.2% acetic acid (v/v) in distilled water and acetonitrile (42:58, v/v). The present method was validated in terms of linearity, lower limit of quantification, lower limit of detection, precision, accuracy, recovery, and stability of MDA according to U.S. Food and Drug Administration (FDA) guidelines. The limit of quantification of MDA was 0.39 μmol/L, which is comparable to other methods. The recovery of the spiked MDA liver samples was in the range of 92.4% to 104.2%. This newly modified HPLC method is specific, sensitive, and accurate and allows the analysis of MDA within 4 min in fish liver but also in other tissues and plasma. © 2014 Institute of Food Technologists®
Witte, Anna Kristina; Fister, Susanne; Mester, Patrick; Schoder, Dagmar; Rossmanith, Peter
2016-11-01
Fast and reliable pathogen detection is an important issue for human health. Since conventional microbiological methods are rather slow, there is growing interest in detection and quantification using molecular methods. The droplet digital polymerase chain reaction (ddPCR) is a relatively new PCR method for absolute and accurate quantification without external standards. Using the Listeria monocytogenes specific prfA assay, we focused on the questions of whether the assay was directly transferable to ddPCR and whether ddPCR was suitable for samples derived from heterogeneous matrices, such as foodstuffs that often included inhibitors and a non-target bacterial background flora. Although the prfA assay showed suboptimal cluster formation, use of ddPCR for quantification of L. monocytogenes from pure bacterial cultures, artificially contaminated cheese, and naturally contaminated foodstuff was satisfactory over a relatively broad dynamic range. Moreover, results demonstrated the outstanding detection limit of one copy. However, while poorer DNA quality, such as resulting from longer storage, can impair ddPCR, internal amplification control (IAC) of prfA by ddPCR, that is integrated in the genome of L. monocytogenes ΔprfA, showed even slightly better quantification over a broader dynamic range. Graphical Abstract Evaluating the absolute quantification potential of ddPCR targeting Listeria monocytogenes prfA.
Microwave-assisted extraction of green coffee oil and quantification of diterpenes by HPLC.
Tsukui, A; Santos Júnior, H M; Oigman, S S; de Souza, R O M A; Bizzo, H R; Rezende, C M
2014-12-01
The microwave-assisted extraction (MAE) of 13 different green coffee beans (Coffea arabica L.) was compared to Soxhlet extraction for oil obtention. The full factorial design applied to the microwave-assisted extraction (MAE), related to time and temperature parameters, allowed to develop a powerful fast and smooth methodology (10 min at 45°C) compared to a 4h Soxhlet extraction. The quantification of cafestol and kahweol diterpenes present in the coffee oil was monitored by HPLC/UV and showed satisfactory linearity (R(2)=0.9979), precision (CV 3.7%), recovery (<93%), limit of detection (0.0130 mg/mL), and limit of quantification (0.0406 mg/mL). The space-time yield calculated on the diterpenes content for sample AT1 (Arabica green coffee) showed a six times higher value compared to the traditional Soxhlet method. Copyright © 2014 Elsevier Ltd. All rights reserved.
Automated lobar quantification of emphysema in patients with severe COPD.
Revel, Marie-Pierre; Faivre, Jean-Baptiste; Remy-Jardin, Martine; Deken, Valérie; Duhamel, Alain; Marquette, Charles-Hugo; Tacelli, Nunzia; Bakai, Anne-Marie; Remy, Jacques
2008-12-01
Automated lobar quantification of emphysema has not yet been evaluated. Unenhanced 64-slice MDCT was performed in 47 patients evaluated before bronchoscopic lung-volume reduction. CT images reconstructed with a standard (B20) and high-frequency (B50) kernel were analyzed using a dedicated prototype software (MevisPULMO) allowing lobar quantification of emphysema extent. Lobar quantification was obtained following (a) a fully automatic delineation of the lobar limits by the software and (b) a semiautomatic delineation with manual correction of the lobar limits when necessary and was compared with the visual scoring of emphysema severity per lobe. No statistically significant difference existed between automated and semiautomated lobar quantification (p > 0.05 in the five lobes), with differences ranging from 0.4 to 3.9%. The agreement between the two methods (intraclass correlation coefficient, ICC) was excellent for left upper lobe (ICC = 0.94), left lower lobe (ICC = 0.98), and right lower lobe (ICC = 0.80). The agreement was good for right upper lobe (ICC = 0.68) and moderate for middle lobe (IC = 0.53). The Bland and Altman plots confirmed these results. A good agreement was observed between the software and visually assessed lobar predominance of emphysema (kappa 0.78; 95% CI 0.64-0.92). Automated and semiautomated lobar quantifications of emphysema are concordant and show good agreement with visual scoring.
Hamidi, Dachriyanus; Aulia, Hilyatul; Susanti, Meri
2017-01-01
Garcinia cowa is a medicinal plant widely grown in Southeast Asia and tropical countries. Various parts of this plant have been used in traditional folk medicine. The bark, latex, and root have been used as an antipyretic agent, while fruit and leaves have been used as an expectorant, for indigestion and improvement of blood circulation. This study aims to determine the concentration of rubraxanthone found in ethyl acetate extract of the stem bark of G. cowa by the high-performance thin-layer chromatography (HPTLC). HPTLC method was performed on precoated silica gel G 60 F254 plates using an HPTLC system with a developed mobile-phase system of chloroform: ethyl acetate: methanol: formic acid (86:6:3:5). A volume of 5 μL of standard and sample solutions was applied to the chromatographic plates. The plates were developed in saturated mode of twin trough chamber at room temperature. The method was validated based on linearity, accuracy, precision, limit of detection (LOD), limit of quantification (LOQ), and specificity. The spots were observed at ultraviolet 243 nm. The linearity of rubraxanthone was obtained between 52.5 and 157.5 ppm/spot. The LOD and LOQ were found to be 4.03 and 13.42 ppm/spot, respectively. The proposed method showed good linearity, precision, accuracy, and high sensitivity. Therefore, it may be applied for the quantification of rubraxanthone in ethyl acetate extract of the stem bark of G. cowa . High performance thin layer chromatography (HPTLC) method provides rapid qualitative and quantitative estimation of rubraxanthone as a marker com¬pound in G. cowa extract used for commercial productRubraxanthone found in ethyl acetate extracts of G. cowa was successfully quantified using HPTLC method. Abbreviations Used : TLC: Thin-layer chromatography, HPTLC: High-performance thin-layer chromatography, LOD: Limit of detection, LOQ: Limit of quantification, ICH: International Conference on Harmonization.
Hidau, Mahendra Kumar; Kolluru, Srikanth; Palakurthi, Srinath
2018-02-01
A sensitive and selective RP-HPLC method has been developed and validated for the quantification of a highly potent poly ADP ribose polymerase inhibitor talazoparib (TZP) in rat plasma. Chromatographic separation was performed with isocratic elution method. Absorbance for TZP was measured with a UV detector (SPD-20A UV-vis) at a λ max of 227 nm. Protein precipitation was used to extract the drug from plasma samples using methanol-acetonitrile (65:35) as the precipitating solvent. The method proved to be sensitive and reproducible over a 100-2000 ng/mL linearity range with a lower limit of quantification (LLQC) of 100 ng/mL. TZP recovery was found to be >85%. Following analytical method development and validation, it was successfully employed to determine the plasma protein binding of TZP. TZP has a high level of protein binding in rat plasma (95.76 ± 0.38%) as determined by dialysis method. Copyright © 2017 John Wiley & Sons, Ltd.
Begou, O; Kontou, A; Raikos, N; Sarafidis, K; Roilides, E; Papadoyannis, I N; Gika, H G
2017-03-15
The development and validation of an ultra-high pressure liquid chromatography (UHPLC) tandem mass spectrometry (MS/MS) method was performed with the aim to be applied for the quantification of plasma teicoplanin concentrations in neonates. Pharmacokinetic data of teicoplanin in the neonatal population is very limited, therefore, a sensitive and reliable method for the determination of all isoforms of teicoplanin applied in a low volume of sample is of real importance. Teicoplanin main components were extracted by a simple acetonitrile precipitation step and analysed on a C18 chromatographic column by a triple quadrupole MS with electrospray ionization. The method provides quantitative data over a linear range of 25-6400ng/mL with LOD 8.5ng/mL and LOQ 25ng/mL for total teicoplanin. The method was applied in plasma samples from neonates to support pharmacokinetic data and proved to be a reliable and fast method for the quantification of teicoplanin concentration levels in plasma of infants during therapy in Intensive Care Unit. Copyright © 2016 Elsevier B.V. All rights reserved.
Establishment of a method for determination of arsenic species in seafood by LC-ICP-MS.
Zmozinski, Ariane V; Llorente-Mirandes, Toni; López-Sánchez, José F; da Silva, Márcia M
2015-04-15
An analytical method for determination of arsenic species (inorganic arsenic (iAs), methylarsonic acid (MA), dimethylarsinic acid (DMA), arsenobetaine (AB), trimethylarsine oxide (TMAO) and arsenocholine (AC)) in Brazilian and Spanish seafood samples is reported. This study was focused on extraction and quantification of inorganic arsenic (iAs), the most toxic form. Arsenic speciation was carried out via LC with both anionic and cationic exchange with ICP-MS detection (LC-ICP-MS). The detection limits (LODs), quantification limits (LOQs), precision and accuracy for arsenic species were established. The proposed method was evaluated using eight reference materials (RMs). Arsenobetaine was the main species found in all samples. The total and iAs concentration in 22 seafood samples and RMs ranged between 0.27-35.2 and 0.02-0.71 mg As kg(-1), respectively. Recoveries ranging from 100% to 106% for iAs, based on spikes, were achieved. The proposed method provides reliable iAs data for future risk assessment analysis. Copyright © 2014 Elsevier Ltd. All rights reserved.
Plasma protein absolute quantification by nano-LC Q-TOF UDMSE for clinical biomarker verification
ILIES, MARIA; IUGA, CRISTINA ADELA; LOGHIN, FELICIA; DHOPLE, VISHNU MUKUND; HAMMER, ELKE
2017-01-01
Background and aims Proteome-based biomarker studies are targeting proteins that could serve as diagnostic, prognosis, and prediction molecules. In the clinical routine, immunoassays are currently used for the absolute quantification of such biomarkers, with the major limitation that only one molecule can be targeted per assay. The aim of our study was to test a mass spectrometry based absolute quantification method for the verification of plasma protein sets which might serve as reliable biomarker panels for the clinical practice. Methods Six EDTA plasma samples were analyzed after tryptic digestion using a high throughput data independent acquisition nano-LC Q-TOF UDMSE proteomics approach. Synthetic Escherichia coli standard peptides were spiked in each sample for the absolute quantification. Data analysis was performed using ProgenesisQI v2.0 software (Waters Corporation). Results Our method ensured absolute quantification of 242 non redundant plasma proteins in a single run analysis. The dynamic range covered was 105. 86% were represented by classical plasma proteins. The overall median coefficient of variation was 0.36, while a set of 63 proteins was found to be highly stable. Absolute protein concentrations strongly correlated with values reviewed in the literature. Conclusions Nano-LC Q-TOF UDMSE proteomic analysis can be used for a simple and rapid determination of absolute amounts of plasma proteins. A large number of plasma proteins could be analyzed, while a wide dynamic range was covered with low coefficient of variation at protein level. The method proved to be a reliable tool for the quantification of protein panel for biomarker verification in the clinical practice. PMID:29151793
Psifidi, Androniki; Dovas, Chrysostomos; Banos, Georgios
2011-01-01
Background Single nucleotide polymorphisms (SNP) have proven to be powerful genetic markers for genetic applications in medicine, life science and agriculture. A variety of methods exist for SNP detection but few can quantify SNP frequencies when the mutated DNA molecules correspond to a small fraction of the wild-type DNA. Furthermore, there is no generally accepted gold standard for SNP quantification, and, in general, currently applied methods give inconsistent results in selected cohorts. In the present study we sought to develop a novel method for accurate detection and quantification of SNP in DNA pooled samples. Methods The development and evaluation of a novel Ligase Chain Reaction (LCR) protocol that uses a DNA-specific fluorescent dye to allow quantitative real-time analysis is described. Different reaction components and thermocycling parameters affecting the efficiency and specificity of LCR were examined. Several protocols, including gap-LCR modifications, were evaluated using plasmid standard and genomic DNA pools. A protocol of choice was identified and applied for the quantification of a polymorphism at codon 136 of the ovine PRNP gene that is associated with susceptibility to a transmissible spongiform encephalopathy in sheep. Conclusions The real-time LCR protocol developed in the present study showed high sensitivity, accuracy, reproducibility and a wide dynamic range of SNP quantification in different DNA pools. The limits of detection and quantification of SNP frequencies were 0.085% and 0.35%, respectively. Significance The proposed real-time LCR protocol is applicable when sensitive detection and accurate quantification of low copy number mutations in DNA pools is needed. Examples include oncogenes and tumour suppressor genes, infectious diseases, pathogenic bacteria, fungal species, viral mutants, drug resistance resulting from point mutations, and genetically modified organisms in food. PMID:21283808
Quantifying construction and demolition waste: an analytical review.
Wu, Zezhou; Yu, Ann T W; Shen, Liyin; Liu, Guiwen
2014-09-01
Quantifying construction and demolition (C&D) waste generation is regarded as a prerequisite for the implementation of successful waste management. In literature, various methods have been employed to quantify the C&D waste generation at both regional and project levels. However, an integrated review that systemically describes and analyses all the existing methods has yet to be conducted. To bridge this research gap, an analytical review is conducted. Fifty-seven papers are retrieved based on a set of rigorous procedures. The characteristics of the selected papers are classified according to the following criteria - waste generation activity, estimation level and quantification methodology. Six categories of existing C&D waste quantification methodologies are identified, including site visit method, waste generation rate method, lifetime analysis method, classification system accumulation method, variables modelling method and other particular methods. A critical comparison of the identified methods is given according to their characteristics and implementation constraints. Moreover, a decision tree is proposed for aiding the selection of the most appropriate quantification method in different scenarios. Based on the analytical review, limitations of previous studies and recommendations of potential future research directions are further suggested. Copyright © 2014 Elsevier Ltd. All rights reserved.
Van den Meersche, Tina; Van Pamel, Els; Van Poucke, Christof; Herman, Lieve; Heyndrickx, Marc; Rasschaert, Geertrui; Daeseleire, Els
2016-01-15
In this study, a fast, simple and selective ultra high performance liquid chromatographic-tandem mass spectrometric (UHPLC-MS/MS) method for the simultaneous detection and quantification of colistin, sulfadiazine, trimethoprim, doxycycline, oxytetracycline and ceftiofur and for the detection of tylosin A in swine manure was developed and validated. First, a simple extraction procedure with acetonitrile and 6% trichloroacetic acid was carried out. Second, the supernatant was evaporated and the pellet was reconstituted in 1 ml of water/acetonitrile (80/20) and 0.1% formic acid. Extracts were filtered and analyzed by UHPLC-MS/MS on a Kinetex C18 column using gradient elution. The method developed was validated according to the criteria of Commission Decision 2002/657/EC. Recovery percentages varied between 94% and 106%, repeatability percentages were within the range of 1.7-9.2% and the intralaboratory reproducibility varied between 2.8% and 9.3% for all compounds, except for tylosin A for which more variation was observed resulting in a higher measurement uncertainty. The limit of detection and limit of quantification varied between 1.1 and 20.2 and between 3.5 and 67.3 μg/kg, respectively. This method was used to determine the presence and concentration of the seven antibiotic residues in swine manure sampled from ten different manure pits on farms where the selected antibiotics were used. A link was found between the antibiotics used and detected, except for ceftiofur which is injected at low doses and degraded readily in swine manure and was therefore not recovered in any of the samples. To the best of our knowledge, this is the first method available for the simultaneous extraction and quantification of colistin with other antibiotic classes. Additionally, colistin was never extracted from swine manure before. Another innovative aspect of this method is the simultaneous detection and quantification of five different classes of antibiotic residues in swine manure. Copyright © 2015 Elsevier B.V. All rights reserved.
Hatanaka, Rafael Rodrigues; Sequinel, Rodrigo; Gualtieri, Carlos Eduardo; Tercini, Antônio Carlos Bergamaschi; Flumignan, Danilo Luiz; de Oliveira, José Eduardo
2013-05-15
Lubricating oils are crucial in the operation of automotive engines because they both reduce friction between moving parts and protect against corrosion. However, the performance of lubricant oil may be affected by contaminants, such as gasoline, diesel, ethanol, water and ethylene glycol. Although there are many standard methods and studies related to the quantification of contaminants in lubricant oil, such as gasoline and diesel oil, to the best of our knowledge, no methods have been reported for the quantification of ethanol in used Otto cycle engine lubrication oils. Therefore, this work aimed at the development and validation of a routine method based on partial least-squares multivariate analysis combined with attenuated total reflectance in the mid-infrared region to quantify ethanol content in used lubrication oil. The method was validated based on its figures of merit (using the net analyte signal) as follows: limit of detection (0.049%), limit of quantification (0.16%), accuracy (root mean square error of prediction=0.089% w/w), repeatability (0.05% w/w), fit (R(2)=0.9997), mean selectivity (0.047), sensitivity (0.011), inverse analytical sensitivity (0.016% w/w(-1)) and signal-to-noise ratio (max: 812.4 and min: 200.9). The results show that the proposed method can be routinely implemented for the quality control of lubricant oils. Copyright © 2013 Elsevier B.V. All rights reserved.
Validated method for quantification of genetically modified organisms in samples of maize flour.
Kunert, Renate; Gach, Johannes S; Vorauer-Uhl, Karola; Engel, Edwin; Katinger, Hermann
2006-02-08
Sensitive and accurate testing for trace amounts of biotechnology-derived DNA from plant material is the prerequisite for detection of 1% or 0.5% genetically modified ingredients in food products or raw materials thereof. Compared to ELISA detection of expressed proteins, real-time PCR (RT-PCR) amplification has easier sample preparation and detection limits are lower. Of the different methods of DNA preparation CTAB method with high flexibility in starting material and generation of sufficient DNA with relevant quality was chosen. Previous RT-PCR data generated with the SYBR green detection method showed that the method is highly sensitive to sample matrices and genomic DNA content influencing the interpretation of results. Therefore, this paper describes a real-time DNA quantification based on the TaqMan probe method, indicating high accuracy and sensitivity with detection limits of lower than 18 copies per sample applicable and comparable to highly purified plasmid standards as well as complex matrices of genomic DNA samples. The results were evaluated with ValiData for homology of variance, linearity, accuracy of the standard curve, and standard deviation.
Szczesny, Damian; Bartosińska, Ewa; Jacyna, Julia; Patejko, Małgorzata; Siluk, Danuta; Kaliszan, Roman
2018-02-01
Trigonelline is a pyridine alkaloid found in fenugreek seeds and coffee beans. Most of the previous studies are concerned with the quantification of trigonelline along with other constituents in coffee herbs or beverages. Only a few have focused on its determination in animal or human tissues by applying different modes of HPLC with UV or MS detection. The aim of the study was to develop and validate a fast and simple method for trigonelline determination in serum by the use of hydrophilic interaction liquid chromatography (HILIC) with ESI-MS/MS detection. Separation of trigonelline was achieved on a Kinetex HILIC column operated at 35°C with acetonitrile-ammonium formate (10 mm, pH = 3) buffer mixture (55:45, v/v) as the mobile phase. The developed method was successfully applied to determine trigonelline concentration in mouse serum after intravenous administration of 10 mg/kg. The developed assay is sensitive (limit of detection = 1.5 ng/mL, limit of quantification = 5.0 ng/mL) and linear in a concentration range from 5.0 to 250.0 ng/mL. Sample preparation is limited to deproteinization, centrifugation and filtration. The application of the HILIC mode of chromatography with MS detection and selection of deuterated trigonelline as internal standard allowed a rapid and precise method of trigonelline quantification to be to developed. Copyright © 2017 John Wiley & Sons, Ltd.
Dupré, Mathieu; Gilquin, Benoit; Fenaille, François; Feraudet-Tarisse, Cécile; Dano, Julie; Ferro, Myriam; Simon, Stéphanie; Junot, Christophe; Brun, Virginie; Becher, François
2015-08-18
The development of rapid methods for unambiguous identification and precise quantification of protein toxins in various matrices is essential for public health surveillance. Nowadays, analytical strategies classically rely on sensitive immunological assays, but mass spectrometry constitutes an attractive complementary approach thanks to direct measurement and protein characterization ability. We developed here an innovative multiplex immuno-LC-MS/MS method for the simultaneous and specific quantification of the three potential biological warfare agents, ricin, staphylococcal enterotoxin B, and epsilon toxin, in complex human biofluids and food matrices. At least 7 peptides were targeted for each toxin (43 peptides in total) with a quadrupole-Orbitrap high-resolution instrument for exquisite detection specificity. Quantification was performed using stable isotope-labeled toxin standards spiked early in the sample. Lower limits of quantification were determined at or close to 1 ng·mL(-1). The whole process was successfully applied to the quantitative analysis of toxins in complex samples such as milk, human urine, and plasma. Finally, we report new data on toxin stability with no evidence of toxin degradation in milk in a 48 h time frame, allowing relevant quantitative toxin analysis for samples collected in this time range.
Liu, Yingchun; Liu, Zhongbo; Sun, Guoxiang; Wang, Yan; Ling, Junhong; Gao, Jiayue; Huang, Jiahao
2015-01-01
A combination method of multi-wavelength fingerprinting and multi-component quantification by high performance liquid chromatography (HPLC) coupled with diode array detector (DAD) was developed and validated to monitor and evaluate the quality consistency of herbal medicines (HM) in the classical preparation Compound Bismuth Aluminate tablets (CBAT). The validation results demonstrated that our method met the requirements of fingerprint analysis and quantification analysis with suitable linearity, precision, accuracy, limits of detection (LOD) and limits of quantification (LOQ). In the fingerprint assessments, rather than using conventional qualitative "Similarity" as a criterion, the simple quantified ratio fingerprint method (SQRFM) was recommended, which has an important quantified fingerprint advantage over the "Similarity" approach. SQRFM qualitatively and quantitatively offers the scientific criteria for traditional Chinese medicines (TCM)/HM quality pyramid and warning gate in terms of three parameters. In order to combine the comprehensive characterization of multi-wavelength fingerprints, an integrated fingerprint assessment strategy based on information entropy was set up involving a super-information characteristic digitized parameter of fingerprints, which reveals the total entropy value and absolute information amount about the fingerprints and, thus, offers an excellent method for fingerprint integration. The correlation results between quantified fingerprints and quantitative determination of 5 marker compounds, including glycyrrhizic acid (GLY), liquiritin (LQ), isoliquiritigenin (ILG), isoliquiritin (ILQ) and isoliquiritin apioside (ILA), indicated that multi-component quantification could be replaced by quantified fingerprints. The Fenton reaction was employed to determine the antioxidant activities of CBAT samples in vitro, and they were correlated with HPLC fingerprint components using the partial least squares regression (PLSR) method. In summary, the method of multi-wavelength fingerprints combined with antioxidant activities has been proved to be a feasible and scientific procedure for monitoring and evaluating the quality consistency of CBAT.
Application of an energy balance method for estimating evapotranspiration in cropping systems
USDA-ARS?s Scientific Manuscript database
Accurate quantification of evapotranspiration (ET, consumptive water use) from planting through harvest is critical for managing the limited water resources for crop irrigation. Our objective was to develop and apply an improved land-crop surface residual energy balance (EB) method for quantifying E...
Loukotková, Lucie; VonTungeln, Linda S; Vanlandingham, Michelle; da Costa, Gonçalo Gamboa
2018-01-01
According to the World Health Organization, the consumption of tobacco products is the single largest cause of preventable deaths in the world, exceeding the total aggregated number of deaths caused by diseases such as AIDS, tuberculosis, and malaria. An important element in the evaluation of the health risks associated with the consumption of tobacco products is the assessment of the internal exposure to the tobacco constituents responsible for their addictive (e.g. nicotine) and carcinogenic (e.g. N-nitrosamines such as NNN and NNK) properties. However, the assessment of the serum levels of these compounds is often challenging from an analytical standpoint, in particular when limited sample volumes are available and low detection limits are required. Currently available analytical methods often rely on complex multi-step sample preparation procedures, which are prone to low analyte recoveries and ex-vivo contamination due to the ubiquitous nature of these compounds as background contaminants. In order to circumvent these problems, we report a facile and highly sensitive method for the simultaneous quantification of nicotine, cotinine, NNN, and NNK in serum samples. The method relies on a simple "one pot" liquid-liquid extraction procedure and isotope dilution ultra-high pressure (UPLC) hydrophilic interaction liquid chromatography (HILIC) coupled with tandem mass spectrometry. The method requires only 10μL of serum and presents a limit of quantification of 0.02nmol (3000pg/mL) nicotine, 0.6pmol (100pg/mL) cotinine, 0.05pmol NNK (10pg/mL), and 0.06pmol NNN (10pg/mL), making it appropriate for pharmacokinetic evaluations. Published by Elsevier B.V.
Jackowetz, J N; Mira de Orduña, R
2013-08-15
Sulphur dioxide (SO2) is essential for the preservation of wines. The presence of SO2 binding compounds in musts and wines may limit sulphite efficacy leading to higher total SO2 additions, which may exceed SO2 limits permitted by law and pose health risks for sensitive individuals. An improved method for the quantification of significant wine SO2 binding compounds is presented that applies a novel sample treatment approach and rapid UHPLC separation. Glucose, galacturonic acid, alpha-ketoglutarate, pyruvate, acetoin and acetaldehyde were derivatised with 2,4-dinitrophenylhydrazine and separated using a solid core C18 phase by ultra high performance liquid chromatography. Addition of EDTA to samples prevented de novo acetaldehyde formation from ethanol oxidation. Optimised derivatisation duration enhanced reproducibility and allowed for glucose and galacturonic acid quantification. High glucose residues were found to interfere with the recovery of other SO2 binders, but practical SO2 concentrations and red wine pigments did not affect derivatisation efficiency. The calibration range, method accuracy, precision and limits of detection were found to be satisfactory for routine analysis of SO2 binders in wines. The current method represents a significant improvement in the comprehensive analysis of SO2 binding wine carbonyls. It allows for the quantification of major SO2 binders at practical analyte concentrations, and uses a simple sample treatment method that prevents treatment artifacts. Equipment utilisation could be reduced by rapid LC separation while maintaining analytical performance parameters. The improved method will be a valuable addition for the analysis of total SO2 binder pools in oenological samples. Published by Elsevier Ltd.
Garelnabi, Mahdi; Litvinov, Dmitry; Parthasarathy, Sampath
2010-01-01
Background: Azelaic acid (AzA) is the best known dicarboxilic acid to have pharmaceutical benefits and clinical applications and also to be associated with some diseases pathophysiology. Materials and Methods: We extracted and methylesterified AzA and determined its concentration in human plasma obtained from healthy individuals and also in mice fed AzA containing diet for three months. Results: AzA was detected in Gas Chromatography (GC) and confirmed by Liquid chromatography mass spectrometry (LCMS), and gas chromatography mass spectrometry (GCMC). Our results have shown that AzA can be determined efficiently in selected biological samples by GC method with 1nM limit of detection (LoD) and the limit of quantification (LoQ); was established at 50nM. Analytical Sensitivity as assayed by hexane demonstrated an analytical sensitivity at 0.050nM. The method has demonstrated 8-10% CV batch repeatability across the sample types and 13-18.9% CV for the Within-Lab Precision analysis. The method has shown that AzA can efficiently be recovered from various sample preparation including liver tissue homogenate (95%) and human plasma (97%). Conclusions: Because of its simplicity and lower limit of quantification, the present method provides a useful tool for determining AzA in various biological sample preparations. PMID:22558586
Sánchez, Raquel; Snell, James; Held, Andrea; Emons, Hendrik
2015-08-01
A simple, robust and reliable method for mercury determination in seawater matrices based on the combination of cold vapour generation and inductively coupled plasma mass spectrometry (CV-ICP-MS) and its complete in-house validation are described. The method validation covers parameters such as linearity, limit of detection (LOD), limit of quantification (LOQ), trueness, repeatability, intermediate precision and robustness. A calibration curve covering the whole working range was achieved with coefficients of determination typically higher than 0.9992. The repeatability of the method (RSDrep) was 0.5 %, and the intermediate precision was 2.3 % at the target mass fraction of 20 ng/kg. Moreover, the method was robust with respect to the salinity of the seawater. The limit of quantification was 2.7 ng/kg, which corresponds to 13.5 % of the target mass fraction in the future certified reference material (20 ng/kg). An uncertainty budget for the measurement of mercury in seawater has been established. The relative expanded (k = 2) combined uncertainty is 6 %. The performance of the validated method was demonstrated by generating results for process control and a homogeneity study for the production of a candidate certified reference material.
Kim, Jaai; Lim, Juntaek; Lee, Changsoo
2013-12-01
Quantitative real-time PCR (qPCR) has been widely used in recent environmental microbial ecology studies as a tool for detecting and quantifying microorganisms of interest, which aids in better understandings of the complexity of wastewater microbial communities. Although qPCR can be used to provide more specific and accurate quantification than other molecular techniques, it does have limitations that must be considered when applying it in practice. This article reviews the principle of qPCR quantification and its applications to microbial ecology studies in various wastewater treatment environments. Here we also address several limitations of qPCR-based approaches that can affect the validity of quantification data: template nucleic acid quality, nucleic acid extraction efficiency, specificity of group-specific primers and probes, amplification of nonviable DNA, gene copy number variation, and limited number of sequences in the database. Even with such limitations, qPCR is reportedly among the best methods for quantitatively investigating environmental microbial communities. The application of qPCR is and will continue to be increasingly common in studies of wastewater treatment systems. To obtain reliable analyses, however, the limitations that have often been overlooked must be carefully considered when interpreting the results. Copyright © 2013 Elsevier Inc. All rights reserved.
Tamura, Masayoshi; Mochizuki, Naoki; Nagatomi, Yasushi; Harayama, Koichi; Toriba, Akira; Hayakawa, Kazuichi
2015-02-16
Three compounds, hypothesized as fumonisin A1 (FA1), fumonisin A2 (FA2), and fumonisin A3 (FA3), were detected in a corn sample contaminated with mycotoxins by high-resolution liquid chromatography-Orbitrap mass spectrometry (LC-Orbitrap MS). One of them has been identified as FA1 synthesized by the acetylation of fumonisin B1 (FB1), and established a method for its quantification. Herein, we identified the two remaining compounds as FA2 and FA3, which were acetylated fumonisin B2 (FB2) and fumonisin B3 (FB3), respectively. Moreover, we examined a method for the simultaneous analysis of FA1, FA2, FA3, FB1, FB2, and FB3. The corn samples were prepared by extraction using a QuEChERS kit and purification using a multifunctional cartridge. The linearity, recovery, repeatability, limit of detection, and limit of quantification of the method were >0.99, 82.9%-104.6%, 3.7%-9.5%, 0.02-0.60 μg/kg, and 0.05-1.98 μg/kg, respectively. The simultaneous analysis of the six fumonisins revealed that FA1, FA2, and FA3 were present in all corn samples contaminated with FB1, FB2, and FB3. The results suggested that corn marketed for consumption can be considered as being contaminated with both the fumonisin B-series and with fumonisin A-series. This report presents the first identification and quantification of FA1, FA2, and FA3 in corn samples.
Quantifying errors without random sampling.
Phillips, Carl V; LaPole, Luwanna M
2003-06-12
All quantifications of mortality, morbidity, and other health measures involve numerous sources of error. The routine quantification of random sampling error makes it easy to forget that other sources of error can and should be quantified. When a quantification does not involve sampling, error is almost never quantified and results are often reported in ways that dramatically overstate their precision. We argue that the precision implicit in typical reporting is problematic and sketch methods for quantifying the various sources of error, building up from simple examples that can be solved analytically to more complex cases. There are straightforward ways to partially quantify the uncertainty surrounding a parameter that is not characterized by random sampling, such as limiting reported significant figures. We present simple methods for doing such quantifications, and for incorporating them into calculations. More complicated methods become necessary when multiple sources of uncertainty must be combined. We demonstrate that Monte Carlo simulation, using available software, can estimate the uncertainty resulting from complicated calculations with many sources of uncertainty. We apply the method to the current estimate of the annual incidence of foodborne illness in the United States. Quantifying uncertainty from systematic errors is practical. Reporting this uncertainty would more honestly represent study results, help show the probability that estimated values fall within some critical range, and facilitate better targeting of further research.
Solid phase microextraction of macrolide, trimethoprim, and sulfonamide antibiotics in wastewaters.
McClure, Evelyn L; Wong, Charles S
2007-10-26
In this work, we optimize a solid phase microextraction (SPME) method for the simultaneous collection of antibiotics (sulfonamides, macrolides, and trimethoprim) present in wastewaters. The performance of the SPME method is compared to a solid phase extraction (SPE) method. Analytes in both cases were quantified by high performance liquid chromatography-tandem mass spectrometry (HPLC-MS-MS) with electrospray ionization. The advantages offered by SPME in this application are: decreased sample volume requirements, ease of sample processing and extraction, decreased cost, and most importantly, elimination of electrospray matrix effects. Despite having higher limits of quantification (16-1380 ng/L in influent and 35-260 ng/L in effluent), nearly all of the compounds found to be present in Edmonton Gold Bar wastewater by SPE were measurable by SPME (i.e., sulfamethoxazole, trimethoprim, erythromycin, and clarithromycin), with values similar to those obtained using the former method. Limits of quantification for the SPE method for the measured compounds were 4.7-15 ng/L and 0.86-6.1 ng/L for influent and effluent, respectively.
Quinolones and tetracyclines in aquaculture fish by a simple and rapid LC-MS/MS method.
Guidi, Letícia Rocha; Santos, Flávio Alves; Ribeiro, Ana Cláudia S R; Fernandes, Christian; Silva, Luiza H M; Gloria, Maria Beatriz A
2018-04-15
The determination of antimicrobials in aquaculture fish is important to ensure food safety. Therefore, simple and fast multiresidue methods are needed. A liquid chromatography tandem mass spectrometry method was developed and validated for the quantification of 14 antimicrobials (quinolones and tetracyclines) in fish. Antimicrobials were extracted with trichloroacetic acid and chromatographic separation was achieved with a C18 column and gradient elution (water and acetonitrile). The method was validated (Decision 2002/657/EC) and it was fit for the purpose. Linearities were established in the matrix and the coefficients of determination were ≥0.98. The method was applied to Nile tilapia and rainbow trout (n = 29) and 14% of them contained enrofloxacin at levels above the limit of quantification (12.53-19.01 µg.kg -1 ) but below the maximum residue limit (100 µg.kg -1 ). Even though prohibited in Brazil and other countries, this antimicrobial reached fish. Measures are needed to ascertain the source of this compound to warrant human safety. Copyright © 2017 Elsevier Ltd. All rights reserved.
Peng, Lian-Xin; Wang, Jing-Bo; Hu, Li-Xue; Zhao, Jiang-Lin; Xiang, Da-Bing; Zou, Liang; Zhao, Gang
2013-01-30
A simple and rapid method for determining emodin, an active factor presented in tartary buckwheat (Fagopyrum tataricum), by high-performance liquid chromatography coupled to a diode array detector (HPLC-DAD) has been developed. Emodin was separated from an extract of buckwheat on a Kromasil-ODS C(18) (250 mm × 4.6 mm × 5 μm) column. The separation is achieved within 15 min on the ODS column. Emodin can be quantified using an external standard method detecting at 436 nm. Good linearity is obtained with a correlation coefficient exceeding 0.9992. The limit of detection and the limit of quantification are 5.7 and 19 μg/L, respectively. This method shows good reproducibility for the quantification of the emodin with a relative standard deviation value of 4.3%. Under optimized extraction conditions, the recovery of emodin was calculated as >90%. The validated method is successfully applied to quantify the emodin in tartary buckwheat and its products.
A Fatigue Crack Size Evaluation Method Based on Lamb Wave Simulation and Limited Experimental Data
He, Jingjing; Ran, Yunmeng; Liu, Bin; Yang, Jinsong; Guan, Xuefei
2017-01-01
This paper presents a systematic and general method for Lamb wave-based crack size quantification using finite element simulations and Bayesian updating. The method consists of construction of a baseline quantification model using finite element simulation data and Bayesian updating with limited Lamb wave data from target structure. The baseline model correlates two proposed damage sensitive features, namely the normalized amplitude and phase change, with the crack length through a response surface model. The two damage sensitive features are extracted from the first received S0 mode wave package. The model parameters of the baseline model are estimated using finite element simulation data. To account for uncertainties from numerical modeling, geometry, material and manufacturing between the baseline model and the target model, Bayesian method is employed to update the baseline model with a few measurements acquired from the actual target structure. A rigorous validation is made using in-situ fatigue testing and Lamb wave data from coupon specimens and realistic lap-joint components. The effectiveness and accuracy of the proposed method is demonstrated under different loading and damage conditions. PMID:28902148
Takemoto, Jody K; Remsberg, Connie M; Yáñez, Jaime A; Vega-Villa, Karina R; Davies, Neal M
2008-11-01
A stereospecific method for analysis of sakuranetin was developed. Separation was accomplished using a Chiralpak AD-RH column with UV (ultraviolet) detection at 288 nm. The stereospecific linear calibration curves ranged from 0.5 to 100 microg/mL. The mean extraction efficiency was >98%. Precision of the assay was <12% (relative standard deviation (R.S.D.)%), and within 10% at the limit of quantitation (0.5 microg/mL). Bias of the assay was lower than 10%, and within 5% at the limit of quantitation. The assay was applied successfully to pharmacokinetic quantification in rats, and the stereospecific quantification in oranges, grapefruit juice, and matico (Piper aduncum L.).
Lowe, Ross H.; Karschner, Erin L.; Schwilke, Eugene W.; Barnes, Allan J.; Huestis, Marilyn A.
2009-01-01
A two-dimensional (2D) gas chromatography/electron impact-mass spectrometry (GC/EI-MS) method for simultaneous quantification of Δ9-tetrahydrocannabinol (THC), 11-hydroxy-Δ9-tetrahydrocannabinol (11-OH-THC), and 11-nor-Δ9-tetrahydrocannabinol-9-carboxylic acid (THCCOOH) in human plasma was developed and validated. The method employs 2D capillary GC and cryofocusing for enhanced resolution and sensitivity. THC, 11-OH-THC, and THCCOOH were extracted by precipitation with acetonitrile followed by solid-phase extraction. GC separation of trimethylsilyl derivatives of analytes was accomplished with two capillary columns in series coupled via a pneumatic Deans switch system. Detection and quantification were accomplished with a bench-top single quadrupole mass spectrometer operated in electron impact-selected ion monitoring mode. Limits of quantification (LOQ) were 0.125, 0.25 and 0.125 ng/mL for THC, 11-OH-THC, and THCCOOH, respectively. Accuracy ranged from 86.0 to 113.0% for all analytes. Intra- and inter-assay precision, as percent relative standard deviation, was less than 14.1% for THC, 11-OH-THC, and THCCOOH. The method was successfully applied to quantification of THC and its 11-OH-THC and THCCOOH metabolites in plasma specimens following controlled administration of THC. PMID:17640656
Khan, Ismail; Iqbal, Zafar; Khan, Abad; Hassan, Muhammad; Nasir, Fazle; Raza, Abida; Ahmad, Lateef; Khan, Amjad; Akhlaq Mughal, Muhammad
2016-10-15
A simple, economical, fast, and sensitive RP-HPLC-UV method has been developed for the simultaneous quantification of Sorafenib and paclitaxel in biological samples and formulations using piroxicam as an internal standard. The experimental conditions were optimized and method was validated according to the standard guidelines. The separation of both the analytes and internal standard was achieved on Discovery HS C18 column (250mm×4.6mm, 5μm) using Acetonitrile and TFA (0.025%) in the ratio of (65:35V/V) as the mobile phase in isocratic mode at a flow rate of 1ml/min, with a wavelength of 245nm and at a column oven temperature of 25°Cin a short run time of 12min. The limits of detection (LLOD) were 5 and 10ng/ml while the limits of quantification (LLOQ) were 10 and 15ng/ml for sorafenib and paclitaxel, respectively. Sorafenib, paclitaxel and piroxicam (IS) were extracted from biological samples by applying acetonitrile as a precipitating and extraction solvent. The method is linear in the range of 15-20,000ng/ml for paclitaxel and 10-5000ng/ml for sorafenib, respectively. The method is sensitive and reliable by considering both of its intra-day and inter-day co-efficient of variance. The method was successfully applied for the quantification of the above mentioned drugs in plasma. The developed method will be applied towards sorafenib and paclitaxel pharmacokinetics studies in animal models. Copyright © 2016 Elsevier B.V. All rights reserved.
Watanabe, Louis Patrick
2017-01-01
Obesity is a disease that has reached epidemic proportions in the United States and has prompted international legislation in an attempt to curtail its prevalence. Despite the fact that one of the most prescribed treatment options for obesity is exercise, the genetic mechanisms underlying exercise response in individuals are still largely unknown. The fruit fly Drosophila melanogaster is a promising new model for studying exercise genetics. Currently, the lack of an accurate method to quantify the amount of exercise performed by the animals is limiting the utility of the Drosophila model for exercise genetics research. To address this limitation, we developed the Rotational Exercise Quantification System (REQS), a novel apparatus that is able to simultaneously induce exercise in flies while recording their activity levels. Thus, the REQS provides a method to standardize Drosophila exercise and ensure that all animals irrespective of genotype and sex experience the same level of exercise. Here, we provide a basic characterization of the REQS, validate its measurements using video-tracking technology, illustrate its potential use by presenting a comparison of two different exercise regimes, and demonstrate that it can be used to detect genotype-dependent variation in activity levels. PMID:29016615
Maruenda, Helena; Vico, Maria del Lujan; Householder, J Ethan; Janovec, John P; Cañari, Cristhian; Naka, Angelica; Gonzalez, Ana E
2013-05-01
This study provides the first chemical investigation of wild-harvested fruits of Vanilla pompona ssp. grandiflora (Lindl.) Soto-Arenas developed in their natural habitat in the Peruvian Amazon. Flowers were hand-pollinated and the resulting fruits were analysed at different developmental stages using an HPLC-DAD method validated for the quantification of glucovanillin and seven other compounds. The method showed satisfactory linearity (r(2)>0.9969), precision (coefficient of variation <2%), recoveries (70-100%), limit of detection (0.008-0.212 μg/ml), and limit of quantification (0.027-0.707 μg/ml). The evaluation of crude and enzyme-hydrolyzed Soxhlet-extracted samples confirmed the leading role of glucosides in fruit development. LC-ESI-MS studies corroborated the identities of four glucosides and seven aglycones, among them vanillin (5.7/100 g), 4-hydroxybenzyl alcohol (3.6/100 g), and anisyl alcohol (7.1/100 g) were found in high concentrations. The attractive flavor/aroma profile exhibited by wild V. pompona fruits supports studies focused on the development of this species as a specialty crop. Copyright © 2012 Elsevier Ltd. All rights reserved.
Sarais, Giorgia; Caboni, Pierluigi; Sarritzu, Erika; Russo, Mariateresa; Cabras, Paolo
2008-05-14
Neem-based insecticides containing azadirachtin and related azadirachtoids are widely used in agriculture. Here, we report an analytical method for the rapid and accurate quantification of the insecticide azadirachtin A and B and other azadirachtoids such as salannin, nimbin, and their deacetylated analogues on tomatoes and peaches. Azadirachtoids were extracted from fruits and vegetables with acetonitrile. Using high-performance liquid chromatography/electrospray ionization tandem mass spectrometer, azadirachtoids were selectively detected monitoring the multiple reaction transitions of sodium adduct precursor ions. For azadirachtin A, calibration was linear over a working range of 1-1000 microg/L with r > 0.996. The limit of detection and limit of quantification for azadirachtin A were 0.4 and 0.8 microg/kg, respectively. The presence of interfering compounds in the peach and tomato extracts was evaluated and found to be minimal. Because of the linear behavior, it was concluded that the multiple reaction transitions of sodium adduct ions can be used for analytical purposes, that is, for the identification and quantification of azadirachtin A and B and related azadirachtoids in fruit and vegetable extracts at trace levels.
Watanabe, Louis Patrick; Riddle, Nicole C
2017-01-01
Obesity is a disease that has reached epidemic proportions in the United States and has prompted international legislation in an attempt to curtail its prevalence. Despite the fact that one of the most prescribed treatment options for obesity is exercise, the genetic mechanisms underlying exercise response in individuals are still largely unknown. The fruit fly Drosophila melanogaster is a promising new model for studying exercise genetics. Currently, the lack of an accurate method to quantify the amount of exercise performed by the animals is limiting the utility of the Drosophila model for exercise genetics research. To address this limitation, we developed the Rotational Exercise Quantification System (REQS), a novel apparatus that is able to simultaneously induce exercise in flies while recording their activity levels. Thus, the REQS provides a method to standardize Drosophila exercise and ensure that all animals irrespective of genotype and sex experience the same level of exercise. Here, we provide a basic characterization of the REQS, validate its measurements using video-tracking technology, illustrate its potential use by presenting a comparison of two different exercise regimes, and demonstrate that it can be used to detect genotype-dependent variation in activity levels.
Hua, Marti Z; Feng, Shaolong; Wang, Shuo; Lu, Xiaonan
2018-08-30
We report the development of a molecularly imprinted polymers-surface-enhanced Raman spectroscopy (MIPs-SERS) method for rapid detection and quantification of a herbicide residue 2,4-dichlorophenoxyacetic acid (2,4-D) in milk. MIPs were synthesized via bulk polymerization and utilized as solid phase extraction sorbent to selectively extract and enrich 2,4-D from milk. Silver nanoparticles were synthesized to facilitate the collection of SERS spectra of the extracts. Based on the characteristic band intensity of 2,4-D (391 cm -1 ), the limit of detection was 0.006 ppm and the limit of quantification was 0.008 ppm. A simple logarithmic working range (0.01-1 ppm) was established, satisfying the sensitivity requirement referring to the maximum residue level of 2,4-D in milk in both Europe and North America. The overall test of 2,4-D for each milk sample required only 20 min including sample preparation. This MIPs-SERS method has potential for practical applications in detecting 2,4-D in agri-foods. Copyright © 2018 Elsevier Ltd. All rights reserved.
Frauen, M; Steinhart, H; Rapp, C; Hintze, U
2001-07-01
A simple, rapid and reproducible method for identification and quantification of iodopropynyl butylcarbamate (IPBC) in different cosmetic formulations is presented. The determination was carried out using a high-performance liquid chromatography (HPLC) procedure on a reversed phase column coupled to a single quadrupole mass spectrometer (MS) via an electrospray ionization (ESI) interface. Detection was performed in the positive selected ion-monitoring mode. In methanol/water extracts from different cosmetic formulations a detection limit between 50 and 100 ng/g could be achieved. A routine analytical procedure could be set up with good quantification reliability (relative standard deviation between 0.9 and 2.9%).
Bihan, Kevin; Sauzay, Chloé; Goldwirt, Lauriane; Charbonnier-Beaupel, Fanny; Hulot, Jean-Sebastien; Funck-Brentano, Christian; Zahr, Noël
2015-02-01
Vemurafenib (Zelboraf) is a new tyrosine kinase inhibitor that selectively targets activated BRAF V600E gene and is indicated for the treatment of advanced BRAF mutation-positive melanoma. We developed a simple method for vemurafenib quantification using liquid chromatography-tandem mass spectrometry. A stability study of vemurafenib in human plasma was also performed. (13)C(6)-vemurafenib was used as the internal standard. A single-step protein precipitation was used for plasma sample preparation. Chromatography was performed on an Acquity UPLC system (Waters) with chromatographic separation by the use of an Acquity UPLC BEH C18 column (2.1 × 50 mm, 1.7-mm particle size; Waters). Quantification was performed using the monitoring of multiple reactions of following transitions: m/z 488.2 → 381.0 for vemurafenib and m/z 494.2 → 387.0 for internal standard. This method was linear over the range from 1.0 to 100.0 mcg/mL. The lower limit of quantification was 0.1 mcg/mL for vemurafenib in plasma. Vemurafenib remained stable for 1 month at all levels tested, when stored indifferently at room temperature (20 °C), at +4 °C, or at -20 °C. This method was used successfully to perform a plasma pharmacokinetic study of vemurafenib in a patient after oral administration at a steady state. This liquid chromatography-tandem mass spectrometry method for vemurafenib quantification in human plasma is simple, rapid, specific, sensitive, accurate, precise, and reliable.
NASA Astrophysics Data System (ADS)
Arsene, Cristian G.; Schulze, Dirk; Kratzsch, Jürgen; Henrion, André
2012-12-01
Amphiphilic peptide conjugation affords a significant increase in sensitivity with protein quantification by electrospray-ionization mass spectrometry. This has been demonstrated here for human growth hormone in serum using N-(3-iodopropyl)-N,N,N-dimethyloctylammonium iodide (IPDOA-iodide) as derivatizing reagent. The signal enhancement achieved in comparison to the method without derivatization enables extension of the applicable concentration range down to the very low concentrations as encountered with clinical glucose suppression tests for patients with acromegaly. The method has been validated using a set of serum samples spiked with known amounts of recombinant 22 kDa growth hormone in the range of 0.48 to 7.65 \\mug/L. The coefficient of variation (CV) calculated, based on the deviation of results from the expected concentrations, was 3.5% and the limit of quantification (LoQ) was determined as 0.4 \\mug/L. The potential of the method as a tool in clinical practice has been demonstrated with patient samples of about 1 \\mug/L.
Zhang, Jingjing; Liang, Jiabi; Tian, Yuan; Zhang, Zunjian; Chen, Yun
2007-10-15
A rapid, sensitive and selective LC-MS/MS method was developed and validated for the quantification of aniracetam in human plasma using estazolam as internal standard (IS). Following liquid-liquid extraction, the analytes were separated using a mobile phase of methanol-water (60:40, v/v) on a reverse phase C18 column and analyzed by a triple-quadrupole mass spectrometer in the selected reaction monitoring (SRM) mode using the respective [M+H]+ ions, m/z 220-->135 for aniracetam and m/z 295-->205 for the IS. The assay exhibited a linear dynamic range of 0.2-100 ng/mL for aniracetam in human plasma. The lower limit of quantification (LLOQ) was 0.2 ng/mL with a relative standard deviation of less than 15%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The validated LC-MS/MS method has been successfully applied to study the pharmacokinetics of aniracetam in healthy male Chinese volunteers.
Psifidi, Androniki; Dovas, Chrysostomos; Banos, Georgios
2011-01-19
Single nucleotide polymorphisms (SNP) have proven to be powerful genetic markers for genetic applications in medicine, life science and agriculture. A variety of methods exist for SNP detection but few can quantify SNP frequencies when the mutated DNA molecules correspond to a small fraction of the wild-type DNA. Furthermore, there is no generally accepted gold standard for SNP quantification, and, in general, currently applied methods give inconsistent results in selected cohorts. In the present study we sought to develop a novel method for accurate detection and quantification of SNP in DNA pooled samples. The development and evaluation of a novel Ligase Chain Reaction (LCR) protocol that uses a DNA-specific fluorescent dye to allow quantitative real-time analysis is described. Different reaction components and thermocycling parameters affecting the efficiency and specificity of LCR were examined. Several protocols, including gap-LCR modifications, were evaluated using plasmid standard and genomic DNA pools. A protocol of choice was identified and applied for the quantification of a polymorphism at codon 136 of the ovine PRNP gene that is associated with susceptibility to a transmissible spongiform encephalopathy in sheep. The real-time LCR protocol developed in the present study showed high sensitivity, accuracy, reproducibility and a wide dynamic range of SNP quantification in different DNA pools. The limits of detection and quantification of SNP frequencies were 0.085% and 0.35%, respectively. The proposed real-time LCR protocol is applicable when sensitive detection and accurate quantification of low copy number mutations in DNA pools is needed. Examples include oncogenes and tumour suppressor genes, infectious diseases, pathogenic bacteria, fungal species, viral mutants, drug resistance resulting from point mutations, and genetically modified organisms in food.
Truta, Liliana; Castro, André L; Tarelho, Sónia; Costa, Pedro; Sales, M Goreti F; Teixeira, Helena M
2016-09-05
Depression is among the most prevalent psychiatric disorders of our society, leading to an increase in antidepressant drug consumption that needs to be accurately determined in whole blood samples in Forensic Toxicology Laboratories. For this purpose, this work presents a new gas chromatography tandem mass spectrometry (GC-MS/MS) method targeting the simultaneous and rapid determination of 14 common Antidepressants in whole blood: 13 Antidepressants (amitriptyline, citalopram, clomipramine, dothiepin, fluoxetine, imipramine, mianserin, mirtazapine, nortryptiline, paroxetine, sertraline, trimipramine and venlafaxine) and 1 Metabolite (N-desmethylclomipramine). Solid-phase extraction was used prior to chromatographic separation. Chromatographic and MS/MS parameters were selected to improve sensitivity, peak resolution and unequivocal identification of the eluted analyte. The detection was performed on a triple quadrupole tandem MS in selected ion monitoring (SIM) mode in tandem, using electronic impact ionization. Clomipramine-D3 and trimipramine-D3 were used as deutered internal standards. The validation parameters included linearity, limits of detection, lower limit of quantification, selectivity/specificity, extraction efficiency, carry-over, precision and robustness, and followed internationally accepted guidelines. Limits of quantification and detection were lower than therapeutic and sub-therapeutic concentration ranges. Overall, the method offered good selectivity, robustness and quick response (<16min) for typical concentration ranges, both for therapeutic and lethal levels. Copyright © 2016 Elsevier B.V. All rights reserved.
Detection and Quantification of Graphene-Family Nanomaterials in the Environment.
Goodwin, David G; Adeleye, Adeyemi S; Sung, Lipiin; Ho, Kay T; Burgess, Robert M; Petersen, Elijah J
2018-04-17
An increase in production of commercial products containing graphene-family nanomaterials (GFNs) has led to concern over their release into the environment. The fate and potential ecotoxicological effects of GFNs in the environment are currently unclear, partially due to the limited analytical methods for GFN measurements. In this review, the unique properties of GFNs that are useful for their detection and quantification are discussed. The capacity of several classes of techniques to identify and/or quantify GFNs in different environmental matrices (water, soil, sediment, and organisms), after environmental transformations, and after release from a polymer matrix of a product is evaluated. Extraction and strategies to combine methods for more accurate discrimination of GFNs from environmental interferences as well as from other carbonaceous nanomaterials are recommended. Overall, a comprehensive review of the techniques available to detect and quantify GFNs are systematically presented to inform the state of the science, guide researchers in their selection of the best technique for the system under investigation, and enable further development of GFN metrology in environmental matrices. Two case studies are described to provide practical examples of choosing which techniques to utilize for detection or quantification of GFNs in specific scenarios. Because the available quantitative techniques are somewhat limited, more research is required to distinguish GFNs from other carbonaceous materials and improve the accuracy and detection limits of GFNs at more environmentally relevant concentrations.
Liu, Shao-Ying; Huang, Xi-Hui; Wang, Xiao-Fang; Jin, Quan; Zhu, Guo-Nian
2014-05-01
This study developed an improved analytical method for the simultaneous quantification of 13 quinolones in cosmetics by ultra high performance liquid chromatography combined with ESI triple quadrupole MS/MS under the multiple reaction monitoring mode. The analytes were extracted and purified by using an SPE cartridge. The limits of quantification ranged from 0.03 to 3.02 μg/kg. The precision for determining the quinolones was <19.39%. The proposed method was successfully developed for the determination of quinolones in real cosmetic samples. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Sadeghipour, F; Veuthey, J L
1997-11-07
A rapid, sensitive and selective liquid chromatographic method with fluorimetric detection was developed for the separation and quantification of four methylenedioxylated amphetamines without interference of other drugs of abuse and common substances found in illicit tablets. The method was validated by examining linearity, precision and accuracy as well as detection and quantification limits. Methylenedioxylated amphetamines were quantified in eight tablets from illicit drug seizures and results were quantitatively compared to HPLC-UV analyses. To demonstrate the better sensitivity of the fluorimetric detection, methylenedioxylated amphetamines were analyzed in serum after a liquid-liquid extraction procedure and results were also compared to HPLC-UV analyses.
Garelnabi, Mahdi; Litvinov, Dmitry; Parthasarathy, Sampath
2010-09-01
Azelaic acid (AzA) is the best known dicarboxilic acid to have pharmaceutical benefits and clinical applications and also to be associated with some diseases pathophysiology. We extracted and methylesterified AzA and determined its concentration in human plasma obtained from healthy individuals and also in mice fed AzA containing diet for three months. AzA was detected in Gas Chromatography (GC) and confirmed by Liquid chromatography mass spectrometry (LCMS), and gas chromatography mass spectrometry (GCMC). Our results have shown that AzA can be determined efficiently in selected biological samples by GC method with 1nM limit of detection (LoD) and the limit of quantification (LoQ); was established at 50nM. Analytical Sensitivity as assayed by hexane demonstrated an analytical sensitivity at 0.050nM. The method has demonstrated 8-10% CV batch repeatability across the sample types and 13-18.9% CV for the Within-Lab Precision analysis. The method has shown that AzA can efficiently be recovered from various sample preparation including liver tissue homogenate (95%) and human plasma (97%). Because of its simplicity and lower limit of quantification, the present method provides a useful tool for determining AzA in various biological sample preparations.
Togola, Anne; Coureau, Charlotte; Guezennec, Anne-Gwenaëlle; Touzé, Solène
2015-05-01
The presence of acrylamide in natural systems is of concern from both environmental and health points of view. We developed an accurate and robust analytical procedure (offline solid phase extraction combined with UPLC/MS/MS) with a limit of quantification (20 ng L(-1)) compatible with toxicity threshold values. The optimized (considering the nature of extraction phases, sampling volumes, and solvent of elution) solid phase extraction (SPE) was validated according to ISO Standard ISO/IEC 17025 on groundwater, surface water, and industrial process water samples. Acrylamide is highly polar, which induces a high variability during the SPE step, therefore requiring the use of C(13)-labeled acrylamide as an internal standard to guarantee the accuracy and robustness of the method (uncertainty about 25 % (k = 2) at limit of quantification level). The specificity of the method and the stability of acrylamide were studied for these environmental media, and it was shown that the method is suitable for measuring acrylamide in environmental studies.
González Paredes, Rosa María; García Pinto, Carmelo; Pérez Pavón, José Luis; Moreno Cordero, Bernardo
2016-09-01
A new method based on headspace programmed-temperature vaporizer gas chromatography with mass spectrometry has been developed and validated for the determination of amino acids (alanine, sarcosine, ethylglycine, valine, leucine, and proline) in human urine samples. Derivatization with ethyl chloroformate was employed successfully to determine the amino acids. The derivatization reaction conditions as well as the variables of the headspace sampling were optimized. The existence of a matrix effect was checked and the analytical characteristics of the method were determined. The limits of detection were 0.15-2.89 mg/L, and the limits of quantification were 0.46-8.67 mg/L. The instrumental repeatability was 1.6-11.5%. The quantification of the amino acids in six urine samples from healthy subjects was performed with the method developed with the one-point standard additions protocol, with norleucine as the internal standard. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Sánchez-Guijo, Alberto; Oji, Vinzenz; Hartmann, Michaela F.; Traupe, Heiko; Wudy, Stefan A.
2015-01-01
Steroids are primarily present in human fluids in their sulfated forms. Profiling of these compounds is important from both diagnostic and physiological points of view. Here, we present a novel method for the quantification of 11 intact steroid sulfates in human serum by LC-MS/MS. The compounds analyzed in our method, some of which are quantified for the first time in blood, include cholesterol sulfate, pregnenolone sulfate, 17-hydroxy-pregnenolone sulfate, 16-α-hydroxy-dehydroepiandrosterone sulfate, dehydroepiandrosterone sulfate, androstenediol sulfate, androsterone sulfate, epiandrosterone sulfate, testosterone sulfate, epitestosterone sulfate, and dihydrotestosterone sulfate. The assay was conceived to quantify sulfated steroids in a broad range of concentrations, requiring only 300 μl of serum. The method has been validated and its performance was studied at three quality controls, selected for each compound according to its physiological concentration. The assay showed good linearity (R2 > 0.99) and recovery for all the compounds, with limits of quantification ranging between 1 and 80 ng/ml. Averaged intra-day and between-day precisions (coefficient of variation) and accuracies (relative errors) were below 10%. The method has been successfully applied to study the sulfated steroidome in diseases such as steroid sulfatase deficiency, proving its diagnostic value. This is, to our best knowledge, the most comprehensive method available for the quantification of sulfated steroids in human blood. PMID:26239050
Leveraging transcript quantification for fast computation of alternative splicing profiles.
Alamancos, Gael P; Pagès, Amadís; Trincado, Juan L; Bellora, Nicolás; Eyras, Eduardo
2015-09-01
Alternative splicing plays an essential role in many cellular processes and bears major relevance in the understanding of multiple diseases, including cancer. High-throughput RNA sequencing allows genome-wide analyses of splicing across multiple conditions. However, the increasing number of available data sets represents a major challenge in terms of computation time and storage requirements. We describe SUPPA, a computational tool to calculate relative inclusion values of alternative splicing events, exploiting fast transcript quantification. SUPPA accuracy is comparable and sometimes superior to standard methods using simulated as well as real RNA-sequencing data compared with experimentally validated events. We assess the variability in terms of the choice of annotation and provide evidence that using complete transcripts rather than more transcripts per gene provides better estimates. Moreover, SUPPA coupled with de novo transcript reconstruction methods does not achieve accuracies as high as using quantification of known transcripts, but remains comparable to existing methods. Finally, we show that SUPPA is more than 1000 times faster than standard methods. Coupled with fast transcript quantification, SUPPA provides inclusion values at a much higher speed than existing methods without compromising accuracy, thereby facilitating the systematic splicing analysis of large data sets with limited computational resources. The software is implemented in Python 2.7 and is available under the MIT license at https://bitbucket.org/regulatorygenomicsupf/suppa. © 2015 Alamancos et al.; Published by Cold Spring Harbor Laboratory Press for the RNA Society.
Quantification of Efficiency of Beneficiation of Lunar Regolith
NASA Technical Reports Server (NTRS)
Trigwell, Steve; Lane, John; Captain, James; Weis, Kyle; Quinn, Jacqueline; Watanabe, Fumiya
2011-01-01
Electrostatic beneficiation of lunar regolith is being researched at Kennedy Space Center to enhance the ilmenite concentration of the regolith for the production of oxygen in in-situ resource utilization on the lunar surface. Ilmenite enrichment of up to 200% was achieved using lunar simulants. For the most accurate quantification of the regolith particles, standard petrographic methods are typically followed, but in order to optimize the process, many hundreds of samples were generated in this study that made the standard analysis methods time prohibitive. In the current studies, X-ray photoelectron spectroscopy (XPS) and Secondary Electron microscopy/Energy Dispersive Spectroscopy (SEM/EDS) were used that could automatically, and quickly, analyze many separated fractions of lunar simulant. In order to test the accuracy of the quantification, test mixture samples of known quantities of ilmenite (2, 5, 10, and 20 wt%) in silica (pure quartz powder), were analyzed by XPS and EDS. The results showed that quantification for low concentrations of ilmenite in silica could be accurately achieved by both XPS and EDS, knowing the limitations of the techniques. 1
Li, Peng; Jia, Junwei; Bai, Lan; Pan, Aihu; Tang, Xueming
2013-07-01
Genetically modified carnation (Dianthus caryophyllus L.) Moonshade was approved for planting and commercialization in several countries from 2004. Developing methods for analyzing Moonshade is necessary for implementing genetically modified organism labeling regulations. In this study, the 5'-transgene integration sequence was isolated using thermal asymmetric interlaced (TAIL)-PCR. Based upon the 5'-transgene integration sequence, conventional and TaqMan real-time PCR assays were established. The relative limit of detection for the conventional PCR assay was 0.05 % for Moonshade using 100 ng total carnation genomic DNA, corresponding to approximately 79 copies of the carnation haploid genome, and the limits of detection and quantification of the TaqMan real-time PCR assay were estimated to be 51 and 254 copies of haploid carnation genomic DNA, respectively. These results are useful for identifying and quantifying Moonshade and its derivatives.
Floren, C; Wiedemann, I; Brenig, B; Schütz, E; Beck, J
2015-04-15
Species fraud and product mislabelling in processed food, albeit not being a direct health issue, often results in consumer distrust. Therefore methods for quantification of undeclared species are needed. Targeting mitochondrial DNA, e.g. CYTB gene, for species quantification is unsuitable, due to a fivefold inter-tissue variation in mtDNA content per cell resulting in either an under- (-70%) or overestimation (+160%) of species DNA contents. Here, we describe a reliable two-step droplet digital PCR (ddPCR) assay targeting the nuclear F2 gene for precise quantification of cattle, horse, and pig in processed meat products. The ddPCR assay is advantageous over qPCR showing a limit of quantification (LOQ) and detection (LOD) in different meat products of 0.01% and 0.001%, respectively. The specificity was verified in 14 different species. Hence, determining F2 in food by ddPCR can be recommended for quality assurance and control in production systems. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.
Singh, Gurmit; Koerner, Terence; Gelinas, Jean-Marc; Abbott, Michael; Brady, Beth; Huet, Anne-Catherine; Charlier, Caroline; Delahaut, Philippe; Godefroy, Samuel Benrejeb
2011-01-01
Malachite green (MG), a member of the N-methylated triphenylmethane class of dyes, has long been used to control fungal and protozoan infections in fish. MG is easily absorbed by fish during waterborne exposure and is rapidly metabolized into leucomalachite green (LMG), which is known for its long residence time in edible fish tissue. This paper describes the development of an enzyme-linked immunosorbent assay (ELISA) for the detection and quantification of LMG in fish tissue. This development includes a simple and versatile method for the conversion of LMG to monodesmethyl-LMG, which is then conjugated to bovine serum albumin (BSA) to produce an immunogenic material. Rabbit polyclonal antibodies are generated against this immunogen, purified and used to develop a direct competitive enzyme-linked immunosorbent assay (ELISA) for the screening and quantification of LMG in fish tissue. The assay performed well, with a limit of detection (LOD) and limit of quantification (LOQ) of 0.1 and 0.3 ng g−1 of fish tissue, respectively. The average extraction efficiency from a matrix of tilapia fillets was approximately 73% and the day-to-day reproducibility for these extractions in the assay was between 5 and 10%. PMID:21623496
Oliveira, Fabiano Aurélio da Silva; Pereira, Elba Nathália Corrêa; Gobbi, Jennifer Mattedi; Soto-Blanco, Benito; Melo, Marília Martins
2018-01-01
Beef meat is an important food that can be contaminated by pesticides. This study aimed to optimize a multiresidue method for identification and quantification of pesticides in beef meat by liquid chromatography coupled to mass spectrometry detection (LC-MS). The extraction and clean-up procedures were adapted from the QuECHERS method. From the 188 analytes tested, the method was validated as qualitative method for 19 compounds and as quantitative method for 152 compounds. The results were satisfactory, yielding coefficients of variation of less than 20% and recoveries ranging from 70% to 120% and expanded uncertainty of less than 50%. The quantification limit was typically 10 µg kg -1 (but 25 µg kg -1 for 12 of the compounds) and the detection limit was 5.0 µg kg -1 . Thirty-two real samples of commercialized beef meat were analyzed without any residual pesticide being found. Thus, the results showed that the multiresidue method for detecting 171 pesticides, using adapted QuECHERS for extraction and LC-MS for detection, is suitable for analyzing beef meat.
Andrade, Mariane A; Lanças, Fernando M
2017-04-14
Ochratoxin A (OTA), a widely studied mycotoxin, can be found in a variety of food matrices. As its concentration in food is generally low (in the order of μg kg -1 ), sample preparation techniques are necessary for the analyte purification and pre-concentration in order to achieve the required low detection limits. The separation and detection methods used for OTA analysis should also offer proper sensitivity in order to allow the adequate quantification of the analyte. This manuscript addresses the development of a methodology aiming the analysis of OTA in wine samples by packed in-tube SPME in flow through extraction mode coupled to HPLC-MS/MS. The in-tube SPME set up utilized a PEEK tube packed with C18 particles as the extraction column. The method was optimized by a central composite design 2 2 +3 extra central points, having as factors the percentage of ACN and time in the sample load step. The functionalities of the method were attested and its analytical conditions, enhanced by using 22% of ACN and 6min in the sample load step. Validation of the method was also accomplished prior to analyses of both dry red wine and dry white wine samples. The method demonstrated proper sensitivity, with detection and quantification limits equal to 0.02 and 0.05μgL -1 , respectively. Linearity and precision exhibited a 0.996 correlation coefficient and RSD under 6%, respectively. The method proved to be accurate at medium and higher concentration levels with a maximum recovery of 73% at higher concentration levels. OTA was not detected in either dry red and dry white wine samples evaluated in this work. If present, it would be at concentrations lower than the detection and quantification limits established for the proposed method, and considered not a potential danger to human health according to our present knowledge. Copyright © 2017 Elsevier B.V. All rights reserved.
Dobnik, David; Spilsberg, Bjørn; Bogožalec Košir, Alexandra; Holst-Jensen, Arne; Žel, Jana
2015-08-18
Presence of genetically modified organisms (GMO) in food and feed products is regulated in many countries. The European Union (EU) has implemented a threshold for labeling of products containing more than 0.9% of authorized GMOs per ingredient. As the number of GMOs has increased over time, standard-curve based simplex quantitative polymerase chain reaction (qPCR) analyses are no longer sufficiently cost-effective, despite widespread use of initial PCR based screenings. Newly developed GMO detection methods, also multiplex methods, are mostly focused on screening and detection but not quantification. On the basis of droplet digital PCR (ddPCR) technology, multiplex assays for quantification of all 12 EU authorized GM maize lines (per April first 2015) were developed. Because of high sequence similarity of some of the 12 GM targets, two separate multiplex assays were needed. In both assays (4-plex and 10-plex), the transgenes were labeled with one fluorescence reporter and the endogene with another (GMO concentration = transgene/endogene ratio). It was shown that both multiplex assays produce specific results and that performance parameters such as limit of quantification, repeatability, and trueness comply with international recommendations for GMO quantification methods. Moreover, for samples containing GMOs, the throughput and cost-effectiveness is significantly improved compared to qPCR. Thus, it was concluded that the multiplex ddPCR assays could be applied for routine quantification of 12 EU authorized GM maize lines. In case of new authorizations, the events can easily be added to the existing multiplex assays. The presented principle of quantitative multiplexing can be applied to any other domain.
Creskey, Marybeth C; Li, Changgui; Wang, Junzhi; Girard, Michel; Lorbetskie, Barry; Gravel, Caroline; Farnsworth, Aaron; Li, Xuguang; Smith, Daryl G S; Cyr, Terry D
2012-07-06
Current methods for quality control of inactivated influenza vaccines prior to regulatory approval include determining the hemagglutinin (HA) content by single radial immunodiffusion (SRID), verifying neuraminidase (NA) enzymatic activity, and demonstrating that the levels of the contaminant protein ovalbumin are below a set threshold of 1 μg/dose. The SRID assays require the availability of strain-specific reference HA antigens and antibodies, the production of which is a potential rate-limiting step in vaccine development and release, particularly during a pandemic. Immune responses induced by neuraminidase also contribute to protection from infection; however, the amounts of NA antigen in influenza vaccines are currently not quantified or standardized. Here, we report a method for vaccine analysis that yields simultaneous quantification of HA and NA levels much more rapidly than conventional HA quantification techniques, while providing additional valuable information on the total protein content. Enzymatically digested vaccine proteins were analyzed by LC-MS(E), a mass spectrometric technology that allows absolute quantification of analytes, including the HA and NA antigens, other structural influenza proteins and chicken egg proteins associated with the manufacturing process. This method has potential application for increasing the accuracy of reference antigen standards and for validating label claims for HA content in formulated vaccines. It can also be used to monitor NA and chicken egg protein content in order to monitor manufacturing consistency. While this is a useful methodology with potential for broad application, we also discuss herein some of the inherent limitations of this approach and the care and caution that must be taken in its use as a tool for absolute protein quantification. The variations in HA, NA and chicken egg protein concentrations in the vaccines analyzed in this study are indicative of the challenges associated with the current manufacturing and quality control testing procedures. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.
Casas, Mònica Escolà; Kretschmann, Andreas Christopher; Andernach, Lars; Opatz, Till; Bester, Kai
2016-06-24
A simple method for the separation of the enantiomers of the fungicide imazalil was developed. Racemic imazalil was separated into its enantiomers with an enantiomeric purity of 99% using HPLC-UV with an enantioselective column (permethylated cyclodextrin) operated in reversed phase mode (water with 0.2% trimethylamine and 0.08% acetic acid and methanol). The absolute configuration of the separated enantiomers was assigned and unequivocally confirmed by optical rotation as well as by vibrational circular dichroism (VCD) and electronic circular dichroism (ECD) combined with ab-initio calculations. The same enantioselective column was also used to develop an HPLC-MS/MS method for the quantification of imazalil enantiomers. The HPLC-MS/MS method reached limits of quantification (LOQs) of 0.025mg/mL with 5μL injections. This method was used to verify imazalil concentrations and enantiomeric fractions in samples from an in vitro test on effects on human steroidogenesis (H295R steroidogenesis assay). The quantification verified the stability of the enantiomers of imazalil during the in vitro tests. Copyright © 2016 Elsevier B.V. All rights reserved.
Yang, Yi; Lu, Dan; Yin, Shuo; Yang, Danni; Chen, Yaling; Li, Yongxin; Sun, Chengjun
2018-04-01
An efficient ultrasound-assisted saponification was developed for simultaneous determination of vitamin E isomers in vegetable oil by high-performance liquid chromatography with fluorescence detection. The samples were saponified ultrasonically with potassium hydroxide solution for only 7 min, then the analytes were extracted with ether. Vitamin E isomers were separated on a C 18 column at 25°C with a mobile phase of methanol/acetonitrile (81:19, v/v) at a flow rate of 0.8 mL/min. Fluorescence detection was operated at 290 nm of excitation wavelength and 327 nm of emission wavelength. Under the optimized conditions, good linearities over the range of 0.001-8.00 μg/mL (r > 0.999) were obtained. Mean recoveries of the method were 88.0-106%, with intra- and interday RSDs less than 11.8 and 12.8%, respectively. The detection limits and quantification limits of the method were 0.30-1.8 and 1.0-6.1 μg/kg, respectively. The recoveries of this method were much higher than that of the quick, easy, cheap, effective, rugged, and safe method and direct dilution method, but were similar to those of hot saponification. This proposed method provides reliable, simple, and rapid quantification of vitamin E isomers in vegetable oils. Five kinds of vegetable oils were analyzed, the quantification results were within the ranges reported by other authors. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Franquesa, Marcella; Hoogduijn, Martin J.; Ripoll, Elia; Luk, Franka; Salih, Mahdi; Betjes, Michiel G. H.; Torras, Juan; Baan, Carla C.; Grinyó, Josep M.; Merino, Ana Maria
2014-01-01
The research field on extracellular vesicles (EV) has rapidly expanded in recent years due to the therapeutic potential of EV. Adipose tissue human mesenchymal stem cells (ASC) may be a suitable source for therapeutic EV. A major limitation in the field is the lack of standardization of the challenging techniques to isolate and characterize EV. The aim of our study was to incorporate new controls for the detection and quantification of EV derived from ASC and to analyze the applicability and limitations of the available techniques. ASC were cultured in medium supplemented with 5% of vesicles-free fetal bovine serum. The EV were isolated from conditioned medium by differential centrifugation with size filtration (0.2 μm). As a control, non-conditioned culture medium was used (control medium). To detect EV, electron microscopy, conventional flow cytometry, and western blot were used. The quantification of the EV was by total protein quantification, ExoELISA immunoassay, and Nanosight. Cytokines and growth factors in the EV samples were measured by multiplex bead array kit. The EV were detected by electron microscope. Total protein measurement was not useful to quantify EV as the control medium showed similar protein contents as the EV samples. The ExoELISA kits had technical troubles and it was not possible to quantify the concentration of exosomes in the samples. The use of Nanosight enabled quantification and size determination of the EV. It is, however, not possible to distinguish protein aggregates from EV with this method. The technologies for quantification and characterization of the EV need to be improved. In addition, we detected protein contaminants in the EV samples, which make it difficult to determine the real effect of EV in experimental models. It will be crucial in the future to optimize design novel methods for purification and characterization of EV. PMID:25374572
Song, Yingshi; Yan, Huiyu; Xu, Jingbo; Ma, Hongxi
2017-09-01
A rapid and sensitive liquid chromatography tandem mass spectrometry detection using selected reaction monitoring in positive ionization mode was developed and validated for the quantification of nodakenin in rat plasma and brain. Pareruptorin A was used as internal standard. A single step liquid-liquid extraction was used for plasma and brain sample preparation. The method was validated with respect to selectivity, precision, accuracy, linearity, limit of quantification, recovery, matrix effect and stability. Lower limit of quantification of nodakenin was 2.0 ng/mL in plasma and brain tissue homogenates. Linear calibration curves were obtained over concentration ranges of 2.0-1000 ng/mL in plasma and brain tissue homogenates for nodakenin. Intra-day and inter-day precisions (relative standard deviation, RSD) were <15% in both biological media. This assay was successfully applied to plasma and brain pharmacokinetic studies of nodakenin in rats after intravenous administration. Copyright © 2017 John Wiley & Sons, Ltd.
Mottier, P; Parisod, V; Turesky, R J
2000-04-01
A method is described for the analysis of the 16 polycyclic aromatic hydrocarbons (PAHs) prioritized by the USA EPA in meat sausages grilled under common barbecue practices. Quantification was done by GC-MS using perdeuterated internal standards (IS). Validation was done by spiking the matrix at the 0.5 and 1.0 microg/kg levels. The average of expected values ranged from 60 to 134% (median 84%) at the 0.5 microg/kg level and from 69 to 121% (median 96%) at the 1.0 microg/kg level. The median of the limits of detection and quantification were 0.06 and 0.20 microg/kg, respectively, for a 4-g test portion. The carcinogenic PAHs were below the quantification limit in all products except one lamb sausage. Comparison of estimates when either 1, 5, or 16 perdeuterated PAHs were used as IS showed that the most accurate determination of PAHs required that each compound be quantified against its corresponding perdeuterated analogue.
Detection and quantification of benzodiazepines in hair by ToF-SIMS: preliminary results
NASA Astrophysics Data System (ADS)
Audinot, J.-N.; Yegles, M.; Labarthe, A.; Ruch, D.; Wennig, R.; Migeon, H.-N.
2003-01-01
Successful results have been obtained in detection and quantification of buprenorphine in urine and hemolysed blood by time of flight-secondary ion mass spectrometry (ToF-SIMS). The present work is focused on four molecules of the benzodiazepine's family: nordiazepam, aminoflunitrozepam, diazepam and oxazepam. These drugs remain difficult to analyse in routine clinical and forensic toxicology because of their thermal instability and low therapeutic range (0.5-5 ng/ml). Internal standards are prepared by means of deuterated molecules. The benzadiazepine and their deuterated form (nordiazepam-D5, amino-flunitrazepam-D3, diazepam-D5 and oxazepam-D5) were added, in known concentration, in urine. These molecules were then extracted with several methods (pH, solvent, etc.) and, after adsorption on a noble metal, analysed by ToF-SIMS. The paper will focus for the different molecules on the comparison of the different preparation procedures, the optimisation of the SIMS conditions, the limits of detection and the limits of quantification.
Salmona, Maud; Fourati, Slim; Feghoul, Linda; Scieux, Catherine; Thiriez, Aline; Simon, François; Resche-Rigon, Matthieu; LeGoff, Jérôme
2016-08-01
Accurate quantification of Epstein-Barr virus (EBV) load in blood is essential for the management of post-transplant lymphoproliferative disorders. The automation of DNA extraction and amplification may improve accuracy and reproducibility. We evaluated the EBV PCR Kit V1 with fully automated DNA extraction and amplification on the m2000 system (Abbott assay). Conversion factor between copies and international units (IU), lower limit of quantification, imprecision and linearity were determined in a whole blood (WB) matrix. Results from 339 clinical WB specimens were compared with a home-brew real-time PCR assay used in our laboratory (in-house assay). The conversion factor between copies and IU was 3.22 copies/IU. The lower limit of quantification (LLQ) was 1000 copies/mL. Intra- and inter-assay coefficients of variation were 3.1% and 7.9% respectively for samples with EBV load higher than the LLQ. The comparison between Abbott assay and in-house assay showed a good concordance (kappa = 0.77). Loads were higher with the Abbott assay (mean difference = 0.62 log10 copies/mL). The EBV PCR Kit V1 assay on the m2000 system provides a reliable and easy-to-use method for quantification of EBV DNA in WB. Copyright © 2016 Elsevier Inc. All rights reserved.
Single cell genomic quantification by non-fluorescence nonlinear microscopy
NASA Astrophysics Data System (ADS)
Kota, Divya; Liu, Jing
2017-02-01
Human epidermal growth receptor 2 (Her2) is a gene which plays a major role in breast cancer development. The quantification of Her2 expression in single cells is limited by several drawbacks in existing fluorescence-based single molecule techniques, such as low signal-to-noise ratio (SNR), strong autofluorescence and background signals from biological components. For rigorous genomic quantification, a robust method of orthogonal detection is highly desirable and we demonstrated it by two non-fluorescent imaging techniques -transient absorption microscopy (TAM) and second harmonic generation (SHG). In TAM, gold nanoparticles (AuNPs) are chosen as an orthogonal probes for detection of single molecules which gives background-free quantifications of single mRNA transcript. In SHG, emission from barium titanium oxide (BTO) nanoprobes was demonstrated which allows stable signal beyond the autofluorescence window. Her2 mRNA was specifically labeled with nanoprobes which are conjugated with antibodies or oligonucleotides and quantified at single copy sensitivity in the cancer cells and tissues. Furthermore, a non-fluorescent super-resolution concept, named as second harmonic super-resolution microscopy (SHaSM), was proposed to quantify individual Her2 transcripts in cancer cells beyond the diffraction limit. These non-fluorescent imaging modalities will provide new dimensions in biomarker quantification at single molecule sensitivity in turbid biological samples, offering a strong cross-platform strategy for clinical monitoring at single cell resolution.
Devos, Christophe; David, Frank; Sandra, Pat
2012-10-26
According to recent directives of the European Union (EU), limits of quantification (LOQ) for the determination of tributyltin (TBT) in surface waters should be ca. 60 pg/L (ppq). This put very stringent requirements on analytical methodologies; definitely when they have to be applied in a routine environment. Stir bar sorptive extraction (SBSE), followed by thermal desorption (TD) and capillary gas chromatography-triple quadrupole mass spectrometry (GC-MS/MS) can provide accurate and precise data at the 2 ng/L level (ppt). For lower concentrations, matrix and reagent interferences together with contamination may provide too high TBT values. A two-dimensional heart-cut GC method was developed to fractionate TBT from interferences. The GC-GC-MS/MS method shows excellent linearity in the range 50 pg/L-4 ng/L, good repeatability (RSD<20% at 200 pg/L), and a limit of detection of 11 pg/L. The method performance is demonstrated with representative samples i.e. harbor water and waste water samples. Copyright © 2012 Elsevier B.V. All rights reserved.
Nebot, Carolina; Regal, Patricia; Miranda, Jose Manuel; Fente, Cristina; Cepeda, Alberto
2013-12-01
Sulfonamides are antimicrobial agents widely employed in animal production and their residues in food could be an important risk to human health. In the dairy industry, large quantities of milk are monitored daily for the presence of sulfonamides. A simple and low-cost extraction protocol followed by a liquid chromatographic-tandem mass spectrometry method was developed for the simultaneous detection of nine sulfonamides in whole milk. The method was validated at the maximum residue limits established by European legislation. The limits of quantification obtained for most sulfonamides were between 12.5 and 25 μg kg(-1), detection capabilities ranged from 116 to 145 μg kg(-1), and recoveries, at 100 μg kg(-1), were greater than 89±12.5%. The method was employed to analyse 100 raw whole bovine milk samples collected from dairy farms in the northwest region of Spain. All of the samples were found to be compliant, but two were positive; one for sulfadiazine and the other for sulfamethoxipyridazine. Copyright © 2013 Elsevier Ltd. All rights reserved.
Silva, Simone Alves da; Sampaio, Geni Rodrigues; Torres, Elizabeth Aparecida Ferraz da Silva
2017-04-15
Among the different food categories, the oils and fats are important sources of exposure to polycyclic aromatic hydrocarbons (PAHs), a group of organic chemical contaminants. The use of a validated method is essential to obtain reliable analytical results since the legislation establishes maximum limits in different foods. The objective of this study was to optimize and validate a method for the quantification of four PAHs [benzo(a)anthracene, chrysene, benzo(b)fluoranthene, benzo(a)pyrene] in vegetable oils. The samples were submitted to liquid-liquid extraction, followed by solid-phase extraction, and analyzed by ultra-high performance liquid chromatography. Under the optimized conditions, the validation parameters were evaluated according to the INMETRO Guidelines: linearity (r2 >0.99), selectivity (no matrix interference), limits of detection (0.08-0.30μgkg -1 ) and quantification (0.25-1.00μgkg -1 ), recovery (80.13-100.04%), repeatability and intermediate precision (<10% RSD). The method was found to be adequate for routine analysis of PAHs in the vegetable oils evaluated. Copyright © 2016. Published by Elsevier Ltd.
Iamanaka, Beatriz Thie; Nakano, Felipe; Lemes, Daniel Ponciano; Ferranti, Larissa Souza; Taniwaki, Marta Hiromi
2014-01-01
A high-performance liquid chromatography-fluorescence (HPLC-FD) method for aflatoxin quantification in brazil nuts was developed. Samples of brazil nuts collected in Brazilian markets were extracted with methanol:water and cleaned using an immunoaffinity column. Aflatoxins were eluted with methanol and a post-column derivatisation was performed with bromine, using a Kobra Cell system. The optimised method for total aflatoxins was sensitive, with detection and quantification limits of 0.05 and 0.25 µg kg⁻¹, respectively. The method was accurate, with recovery values of 87.6%; 85.3% and 85.0% for 0.5, 5.0 and 14.6 µg kg⁻¹ spiked levels, respectively. It was shown that the method was applicable to brazil nuts. From a total of 95 brazil nut samples analysed from 21 São Paulo supermarket samples and 51 Manaus and 23 Belém street markets samples, 37.9% showed detectable levels of aflatoxins and three exceeded the recommended Codex Alimentarius limit of 10 µg kg⁻¹ for ready-to-eat brazil nuts.
Fukuda, Jun; Iwura, Takafumi; Yanagihara, Shigehiro; Kano, Kenji
2014-10-01
Hollow-fiber-flow field-flow fractionation (HF5) separates protein molecules on the basis of the difference in the diffusion coefficient, and can evaluate the aggregation ratio of proteins. However, HF5 is still a minor technique because information on the separation conditions is limited. We examined in detail the effect of different settings, including the main-flow rate, the cross-flow rate, the focus point, the injection amount, and the ionic strength of the mobile phase, on fractographic characteristics. On the basis of the results, we proposed optimized conditions of the HF5 method for quantification of monoclonal antibody in sample solutions. The HF5 method was qualified regarding the precision, accuracy, linearity of the main peak, and quantitation limit. In addition, the HF5 method was applied to non-heated Mab A and heat-induced-antibody-aggregate-containing samples to evaluate the aggregation ratio and the distribution extent. The separation performance was comparable with or better than that of conventional methods including analytical ultracentrifugation-sedimentation velocity and asymmetric-flow field-flow fractionation.
Mufusama, Jean-Pierre; Hoellein, Ludwig; Feineis, Doris; Holzgrabe, Ulrike; Bringmann, Gerhard
2018-05-29
A simple and robust CZE method was developed for the separation and quantification of the antimalarial compound amodiaquine as well as three of its synthetic impurities at a concentration equal to or lower than 0.5%. For capillary electrophoresis, a fused-silica capillary, a background electrolyte of 100 mM sodium phosphate buffer at a pH value of 6.2, a voltage of +20 kV, and a detection wavelength of 220 nm were used, allowing the determination of the analytes within 20 minutes. The method was validated according to the guideline Q2(R1) of the International Council for Harmonization with respect to linearity, precision, accuracy, limit of detection and limit of quantification, and was successfully applied to evaluate the quality of drug samples collected in the Democratic Republic of the Congo. Quantitative analysis results obtained by the CZE method were compared to those obtained with the contemporary HPLC method described in The International Pharmacopoeia. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.
Khaksari, Maryam; Mazzoleni, Lynn R; Ruan, Chunhai; Kennedy, Robert T; Minerick, Adrienne R
2017-04-01
Two separate liquid chromatography (LC)-mass spectrometry (MS) methods were developed for determination and quantification of water-soluble and fat-soluble vitamins in human tear and blood serum samples. The water-soluble vitamin method was originally developed to detect vitamins B 1 , B 2 , B 3 (nicotinamide), B 5 , B 6 (pyridoxine), B 7 , B 9 and B 12 while the fat-soluble vitamin method detected vitamins A, D 3 , 25(OH)D 3, E and K 1 . These methods were then validated with tear and blood serum samples. In this data in brief article, we provide details on the two LC-MS methods development, methods sensitivity, as well as precision and accuracy for determination of vitamins in human tears and blood serum. These methods were then used to determine the vitamin concentrations in infant and parent samples under a clinical study which were reported in "Determination of Water-Soluble and Fat-Soluble Vitamins in Tears and Blood Serum of Infants and Parents by Liquid Chromatography/Mass Spectrometry DOI:10.1016/j.exer.2016.12.007 [1]". This article provides more details on comparison of vitamin concentrations in the samples with the ranges reported in the literature along with the medically accepted normal ranges. The details on concentrations below the limits of detection (LOD) and limits of quantification (LOQ) are also discussed. Vitamin concentrations were also compared and cross-correlated with clinical data and nutritional information. Significant differences and strongly correlated data were reported in [1]. This article provides comprehensive details on the data with slight differences or slight correlations.
Maragos, Chris M; Busman, Mark; Ma, Liang; Bobell, John
2015-01-01
Patulin is a mycotoxin commonly found in certain fruit and fruit products. For this reason many countries have established regulatory limits pertaining to, in particular, apple juice and apple products. Fruit leathers are produced by dehydrating fruit puree, leaving a sweet product that has a leathery texture. A recent report in the literature described the detection of patulin at substantial levels in fruit leathers. To investigate this further, an ultra-high-performance liquid chromatography-photodiode array (UPLC-PDA) method was developed for the sensitive detection of patulin in fruit leathers. Investigations were also made of the suitability of direct analysis in real time-mass spectrometry (DART-MS) for detection of patulin from the surface of fruit leathers. Results indicated DART-MS was insufficiently sensitive for quantification from the surface of home-style apple leathers, although patulin spiked onto the surface of leather or peel could be detected. The UPLC-PDA method was used to determine the fate of patulin during the preparation of home-made fruit leathers. Interestingly, when a home-style process was used, the patulin was not destroyed, but rather increased in concentration as the puree was dehydrated. The UPLC-PDA method was also used to screen for patulin in commercial fruit leathers. Of the 36 products tested, 14 were above the limit of detection (3.5 μg kg(-1)) and nine were above the limit of quantification (12 μg kg(-1)). Positive samples were confirmed by UPLC-MS/MS. Only one sample was found above the US regulatory limit for single-strength apple juice products (50 μg kg(-1)). These results suggest patulin can be concentrated during preparation and can be found in fruit leathers. The limited survey suggests that patulin is fairly prevalent in such commercial products, but that the levels are usually low.
Agrawal, Poonam; Laddha, Kirti
2017-04-01
This study was undertaken to isolate and quantify aristolochic acid in Aristolochia indica stem and Apama siliquosa root. Aristolochic acid is an important biomarker component present in the Aristolochiaceae family. The isolation method involved simple solvent extraction, precipitation and further purification, using recrystallization. The structure of the compound was confirmed using infrared spectroscopy, mass spectrometry and nuclear magnetic resonance. A specific and rapid high-performance thin layer chromatography (HPTLC) method was developed for analysis of aristolochic acid. The method involved separation on the silica gel 60 F 254 plates using the single solvent system of n-hexane: chloroform: methanol. The method showed good linear relationship in the range 0.4-2.0 μg/spot with r 2 = 0.998. The limit of detection and limit of quantification were 62.841 ng/spot and 209.47 ng/spot, respectively. The proposed validated HPTLC method was found to be an easy to use, accurate and convenient method that could be successfully used for standardization and quality assessment of herbal material as well as formulations containing different species of the Aristolochiaceae family. Copyright © 2016. Published by Elsevier B.V.
Rothenhöfer, Martin; Scherübl, Rosmarie; Bernhardt, Günther; Heilmann, Jörg; Buschauer, Armin
2012-07-27
Purified oligomers of hyalobiuronic acid are indispensable tools to elucidate the physiological and pathophysiological role of hyaluronan degradation by various hyaluronidase isoenzymes. Therefore, we established and validated a novel sensitive, convenient, rapid, and cost-effective high performance thin layer chromatography (HPTLC) method for the qualitative and quantitative analysis of small saturated hyaluronan oligosaccharides consisting of 2-4 hyalobiuronic acid moieties. The use of amino-modified silica as stationary phase allows a simple reagent-free in situ derivatization by heating, resulting in a very low limit of detection (7-19 pmol per band, depending on the analyzed saturated oligosaccharide). By this derivatization procedure for the first time densitometric quantification of the analytes could be performed by HPTLC. The validated method showed a quantification limit of 37-71 pmol per band and was proven to be superior in comparison to conventional detection of hyaluronan oligosaccharides. The analytes were identified by hyphenation of normal phase planar chromatography to mass spectrometry (TLC-MS) using electrospray ionization. As an alternative to sequential techniques such as high performance liquid chromatography (HPLC) and capillary electrophoresis (CE), the validated HPTLC quantification method can easily be automated and is applicable to the analysis of multiple samples in parallel. Copyright © 2012 Elsevier B.V. All rights reserved.
Honda, Akira; Yamashita, Kouwa; Ikegami, Tadashi; Hara, Takashi; Miyazaki, Teruo; Hirayama, Takeshi; Numazawa, Mitsuteru; Matsuzaki, Yasushi
2009-01-01
We describe a new sensitive and specific method for the quantification of serum malonate (malonic acid, MA), which could be a new biomarker for de novo lipogenesis (fatty acid synthesis). This method is based upon a stable isotope-dilution technique using LC-MS/MS. MA from 50 μl of serum was derivatized into di-(1-methyl-3-piperidinyl)malonate (DMP-MA) and quantified by LC-MS/MS using the positive electrospray ionization mode. The detection limit of the DMP-MA was approximately 4.8 fmol (500 fg) (signal-to-noise ratio = 10), which was more than 100 times more sensitive compared with that of MA by LC-MS/MS using the negative electrospray ionization mode. The relative standard deviations between sample preparations and measurements made using the present method were 4.4% and 3.2%, respectively, by one-way ANOVA. Recovery experiments were performed using 50 μl aliquots of normal human serum spiked with 9.6 pmol (1 ng) to 28.8 pmol (3 ng) of MA and were validated by orthogonal regression analysis. The results showed that the estimated amount within a 95% confidence limit was 14.1 ± 1.1 pmol, which was in complete agreement with the observed X¯0 = 15.0 ± 0.6 pmol, with a mean recovery of 96.0%. This method provides reliable and reproducible results for the quantification of MA in human serum. PMID:19403942
Touron-Bodilis, A; Pougnard, C; Frenkiel-Lebossé, H; Hallier-Soulier, S
2011-08-01
This study was designed to evaluate the usefulness of quantification by real-time PCR as a management tool to monitor concentrations of Legionella spp. and Legionella pneumophila in industrial cooling systems and its ability to anticipate culture trends by the French standard method (AFNOR T90-431). Quantifications of Legionella bacteria were achieved by both methods on samples from nine cooling systems with different water qualities. Proportion of positive samples for L. pneumophila quantified by PCR was clearly lower in deionized or river waters submitted to a biocide treatment than in raw river waters, while positive samples for Legionella spp. were quantified for almost all the samples. For some samples containing PCR inhibitors, high quantification limits (up to 4·80 × 10(5) GU l(-1) ) did not allow us to quantify L. pneumophila, when they were quantified by culture. Finally, the monitoring of concentrations of L. pneumophila by both methods showed similar trends for 57-100% of the samples. These results suggest that, if some methodological steps designed to reduce inhibitory problems and thus decrease the quantification limits, could be developed to quantify Legionella in complex waters, the real-time PCR could be a valuable complementary tool to monitor the evolution of L. pneumophila concentrations. This study shows the possibility of using real-time PCR to monitor L. pneumophila proliferations in cooling systems and the importance to adapt nucleic acid extraction and purification protocols to raw waters. Journal of Applied Microbiology © 2011 The Society for Applied Microbiology. No claim to French Government works.
Genovese, S; Epifano, F; Carlucci, G; Marcotullio, M C; Curini, M; Locatelli, M
2010-10-10
Oxyprenylated natural products (isopentenyloxy-, geranyloxy- and the less spread farnesyloxy-compounds and their biosynthetic derivatives) represent a family of secondary metabolites that have been consider for years merely as biosynthetic intermediates of the most abundant C-prenylated derivatives. Many of the isolated oxyprenylated natural products were shown to exert in vitro and in vivo remarkable anti-cancer and anti-inflammatory effects. 4'-Geranyloxyferulic acid [3-(4'-geranyloxy-3'-methoxyphenyl)-2-trans-propenoic] has been discovered as a valuable chemopreventive agent of several types of cancer. After development of a high yield and "eco-friendly" synthetic scheme of this secondary metabolite, starting from cheap and non-toxic reagents and substrates, we developed a new HPLC-DAD method for its quantification in grapefruit skin extract. A preliminary study on C18 column showed the separation between GOFA and boropinic acid (having the same core but with an isopentenyloxy side chain), used as internal standard. The tested column were thermostated at 28+/-1 degrees C and the separation was achieved in gradient condition at a flow rate of 1 mL/min with a starting mobile phase of H(2)O:methanol (40:60, v/v, 1% formic acid). The limit of detection (LOD, S/N=3) was 0.5 microg/mL and the limit of quantification (LOQ, S/N=10) was 1 microg/mL. Matrix-matched standard curves showed linearity up to 75 microg/mL. In the analytical range the precision (RSD%) values were
UFLC-ESI-MS/MS analysis of multiple mycotoxins in medicinal and edible Areca catechu.
Liu, Hongmei; Luo, Jiaoyang; Kong, Weijun; Liu, Qiutao; Hu, Yichen; Yang, Meihua
2016-05-01
A robust, sensitive and reliable ultra fast liquid chromatography combined with electrospray ionization tandem mass spectrometry (UFLC-ESI-MS/MS) was optimized and validated for simultaneous identification and quantification of eleven mycotoxins in medicinal and edible Areca catechu, based on one-step extraction without any further clean-up. Separation and quantification were performed in both positive and negative modes under multiple reaction monitoring (MRM) in a single run with zearalanone (ZAN) as internal standard. The chromatographic conditions and MS/MS parameters were carefully optimized. Matrix-matched calibration was recommended to reduce matrix effects and improve accuracy, showing good linearity within wide concentration ranges. Limits of quantification (LOQ) were lower than 50 μg kg(-1), while limits of detection (LOD) were in the range of 0.1-20 μg kg(-1). The accuracy of the developed method was validated for recoveries, ranging from 85% to 115% with relative standard deviation (RSD) ≤14.87% at low level, from 75% to 119% with RSD ≤ 14.43% at medium level and from 61% to 120% with RSD ≤ 13.18% at high level, respectively. Finally, the developed multi-mycotoxin method was applied for screening of these mycotoxins in 24 commercial samples. Only aflatoxin B2 and zearalenone were found in 2 samples. This is the first report on the application of UFLC-ESI(+/-)-MS/MS for multi-class mycotoxins in A. catechu. The developed method with many advantages of simple pretreatment, rapid determination and high sensitivity is a proposed candidate for large-scale detection and quantification of multiple mycotoxins in other complex matrixes. Copyright © 2016 Elsevier Ltd. All rights reserved.
Tamura, Masayoshi; Mochizuki, Naoki; Nagatomi, Yasushi; Harayama, Koichi; Toriba, Akira; Hayakawa, Kazuichi
2015-01-01
Three compounds, hypothesized as fumonisin A1 (FA1), fumonisin A2 (FA2), and fumonisin A3 (FA3), were detected in a corn sample contaminated with mycotoxins by high-resolution liquid chromatography-Orbitrap mass spectrometry (LC-Orbitrap MS). One of them has been identified as FA1 synthesized by the acetylation of fumonisin B1 (FB1), and established a method for its quantification. Herein, we identified the two remaining compounds as FA2 and FA3, which were acetylated fumonisin B2 (FB2) and fumonisin B3 (FB3), respectively. Moreover, we examined a method for the simultaneous analysis of FA1, FA2, FA3, FB1, FB2, and FB3. The corn samples were prepared by extraction using a QuEChERS kit and purification using a multifunctional cartridge. The linearity, recovery, repeatability, limit of detection, and limit of quantification of the method were >0.99, 82.9%–104.6%, 3.7%–9.5%, 0.02–0.60 μg/kg, and 0.05–1.98 μg/kg, respectively. The simultaneous analysis of the six fumonisins revealed that FA1, FA2, and FA3 were present in all corn samples contaminated with FB1, FB2, and FB3. The results suggested that corn marketed for consumption can be considered as being contaminated with both the fumonisin B-series and with fumonisin A-series. This report presents the first identification and quantification of FA1, FA2, and FA3 in corn samples. PMID:25690692
Singhal, Puran; Gaur, Ashwani; Gautam, Anirudh; Varshney, Brijesh; Paliwal, Jyoti; Batra, Vijay
2007-11-01
A simple, sensitive and rapid liquid chromatography/tandem mass spectrometric (LC-MS/MS) method was developed and validated for quantification of piperaquine, an antimalarial drug, in human plasma using its structural analogue, piperazine bis chloroquinoline as internal standard (IS). The method involved a simple protein precipitation with methanol followed by rapid isocratic elution of analytes with 10mM ammonium acetate buffer/methanol/formic acid/ammonia solution (25/75/0.2/0.15, v/v) on Chromolith SpeedROD RP-18e reversed phase chromatographic column and quantification by mass spectrometry in the multiple reaction monitoring mode (MRM). The precursor to product ion transitions of m/z 535.3-->288.2 and m/z 409.1-->205.2 were used to measure the analyte and the IS, respectively. The assay exhibited a linear dynamic range of 1.0-250.2 ng/mL for piperaquine in plasma. The limit of detection (LOD) and lower limit of quantification (LLOQ) in plasma were 0.2 and 1.0 ng/mL, respectively. Acceptable precision and accuracy (+/-20% deviation for LLOQ standard and +/-15% deviation for other standards from the respective nominal concentration) were obtained for concentrations over the standard curve ranges. A run time of 2.5 min for a sample made it possible to achieve a throughput of more than 400 plasma samples analyzed per day. The validated method was successfully applied to analyze human plasma samples from phase-1 clinical studies. The mean pharmacokinetic parameters of piperaquine following 1000 mg oral dose: observed maximum plasma concentration (Cmax), time to maximum plasma concentration (Tmax) and elimination half-life (T1/2) were 46.1 ng/mL, 3.8h and 13 days, respectively.
Hupert, Michelle; Elfgen, Anne; Schartmann, Elena; Schemmert, Sarah; Buscher, Brigitte; Kutzsche, Janine; Willbold, Dieter; Santiago-Schübel, Beatrix
2018-01-15
During preclinical drug development, a method for quantification of unlabeled compounds in blood plasma samples from treatment or pharmacokinetic studies in mice is required. In the current work, a rapid, specific, sensitive and validated liquid chromatography mass-spectrometric UHPLC-ESI-QTOF-MS method was developed for the quantification of the therapeutic compound RD2 in mouse plasma. RD2 is an all-D-enantiomeric peptide developed for the treatment of Alzheimer's disease, a progressive neurodegenerative disease finally leading to dementia. Due to RD2's highly hydrophilic properties, the sample preparation and the chromatographic separation and quantification were very challenging. The chromatographic separation of RD2 and its internal standard were accomplished on an Acquity UPLC BEH C18 column (2.1 × 100 mm, 1.7 μm particle size) within 6.5 min at 50 °C with a flow rate of 0.5 mL/min. Mobile phases consisted of water and acetonitrile with 1% formic acid and 0.025% heptafluorobutyric acid, respectively. Ions were generated by electrospray ionization (ESI) in the positive mode and the peptide was quantified by QTOF-MS. The developed extraction method for RD2 from mouse plasma revealed complete recovery. The linearity of the calibration curve was in the range of 5.3 ng/mL to 265 ng/mL (r 2 > 0.999) with a lower limit of detection (LLOD) of 2.65 ng/mL and a lower limit of quantification (LLOQ) of 5.3 ng/mL. The intra-day and inter-day accuracy and precision of RD2 in plasma ranged from -0.54% to 2.21% and from 1.97% to 8.18%, respectively. Moreover, no matrix effects were observed and RD2 remained stable in extracted mouse plasma at different conditions. Using this validated bioanalytical method, plasma samples of unlabeled RD2 or placebo treated mice were analyzed. The herein developed UHPLC-ESI-QTOF-MS method is a suitable tool for the quantitative analysis of unlabeled RD2 in plasma samples of treated mice. Copyright © 2017 Elsevier B.V. All rights reserved.
Gil, Jeovanis; Cabrales, Ania; Reyes, Osvaldo; Morera, Vivian; Betancourt, Lázaro; Sánchez, Aniel; García, Gerardo; Moya, Galina; Padrón, Gabriel; Besada, Vladimir; González, Luis Javier
2012-02-23
Growth hormone-releasing peptide 6 (GHRP-6, His-(DTrp)-Ala-Trp-(DPhe)-Lys-NH₂, MW=872.44 Da) is a potent growth hormone secretagogue that exhibits a cytoprotective effect, maintaining tissue viability during acute ischemia/reperfusion episodes in different organs like small bowel, liver and kidneys. In the present work a quantitative method to analyze GHRP-6 in human plasma was developed and fully validated following FDA guidelines. The method uses an internal standard (IS) of GHRP-6 with ¹³C-labeled Alanine for quantification. Sample processing includes a precipitation step with cold acetone to remove the most abundant plasma proteins, recovering the GHRP-6 peptide with a high yield. Quantification was achieved by LC-MS in positive full scan mode in a Q-Tof mass spectrometer. The sensitivity of the method was evaluated, establishing the lower limit of quantification at 5 ng/mL and a range for the calibration curve from 5 ng/mL to 50 ng/mL. A dilution integrity test was performed to analyze samples at higher concentration of GHRP-6. The validation process involved five calibration curves and the analysis of quality control samples to determine accuracy and precision. The calibration curves showed R² higher than 0.988. The stability of the analyte and its internal standard (IS) was demonstrated in all conditions the samples would experience in a real time analyses. This method was applied to the quantification of GHRP-6 in plasma from nine healthy volunteers participating in a phase I clinical trial. Copyright © 2011 Elsevier B.V. All rights reserved.
Qian, Yiyun; Zhu, Zhenhua; Duan, Jin-Ao; Guo, Sheng; Shang, Erxin; Tao, Jinhua; Su, Shulan; Guo, Jianming
2017-01-15
A highly sensitive method using ultra-high-pressure liquid chromatography coupled with linear ion trap-Orbitrap tandem mass spectrometry (UHPLC-LTQ-Orbitrap-MS) has been developed and validated for the simultaneous identification and quantification of ginkgolic acids and semi-quantification of their metabolites in rat plasma. For the five selected ginkgolic acids, the method was found to be with good linearities (r>0.9991), good intra- and inter-day precisions (RSD<15%), and good accuracies (RE, from -10.33% to 4.92%) as well. Extraction recoveries, matrix effects and stabilities for rat plasm samples were within the required limits. The validated method was successfully applied to investigate the pharmacokinetics of the five ginkgolic acids in rat plasma after oral administration of 3 dosage groups (900mg/kg, 300mg/kg and 100mg/kg). Meanwhile, six metabolites of GA (15:1) and GA (17:1) were identified by comparison of MS data with reported values. The results of validation in terms of linear ranges, precisions and stabilities were established for semi-quantification of metabolites. The curves of relative changes of these metabolites during the metabolic process were constructed by plotting the peak area ratios of metabolites to salicylic acid (internal standard, IS), respectively. Double peaks were observed in all 3 dose groups. Different type of metabolites and different dosage of each metabolite both resulted in different T max . Copyright © 2016 Elsevier B.V. All rights reserved.
Fabregat-Cabello, Neus; Sancho, Juan V; Vidal, Andreu; González, Florenci V; Roig-Navarro, Antoni Francesc
2014-02-07
We present here a new measurement method for the rapid extraction and accurate quantification of technical nonylphenol (NP) and 4-t-octylphenol (OP) in complex matrix water samples by UHPLC-ESI-MS/MS. The extraction of both compounds is achieved in 30min by means of hollow fiber liquid phase microextraction (HF-LPME) using 1-octanol as acceptor phase, which provides an enrichment (preconcentration) factor of 800. On the other hand we have developed a quantification method based on isotope dilution mass spectrometry (IDMS) and singly (13)C1-labeled compounds. To this end the minimal labeled (13)C1-4-(3,6-dimethyl-3-heptyl)-phenol and (13)C1-t-octylphenol isomers were synthesized, which coelute with the natural compounds and allows the compensation of the matrix effect. The quantification was carried out by using isotope pattern deconvolution (IPD), which permits to obtain the concentration of both compounds without the need to build any calibration graph, reducing the total analysis time. The combination of both extraction and determination techniques have allowed to validate for the first time a HF-LPME methodology at the required levels by legislation achieving limits of quantification of 0.1ngmL(-1) and recoveries within 97-109%. Due to the low cost of HF-LPME and total time consumption, this methodology is ready for implementation in routine analytical laboratories. Copyright © 2013 Elsevier B.V. All rights reserved.
Schrübbers, Lars C; Masís-Mora, Mario; Rojas, Elizabeth Carazo; Valverde, Bernal E; Christensen, Jan H; Cedergreen, Nina
2016-01-01
Glyphosate is a commonly applied herbicide in coffee plantations. Because of its non-selective mode of action it can damage the crop exposed through spray drift. Therefore, it is of interest to study glyphosate fate in coffee plants. The aim of this study was to develop an analytical method for accurate and precise quantification of glyphosate and its main metabolite aminomethylphosphonic acid (AMPA) at trace levels in coffee leaves using liquid chromatography with single-quadrupole mass spectrometry detection. The method is based on a two-step solid phase extraction (SPE) with an intermediate derivatization reaction using 9-fluorenylmethylchloroformate (FMOC). An isotope dilution method was used to account for matrix effects and to enhance the confidence in analyte identification. The limit of quantification (LOQ) for glyphosate and AMPA in coffee leaves was 41 and 111 μg kg(-1) dry weight, respectively. For the method optimization a design of experiments (DOE) approach was used. The sample clean-up procedure can be simplified for the analysis of less challenging matrices, for laboratories having a tandem mass spectrometry detector and for cases in which quantification limits above 0.1 mg kg(-1) are acceptable, which is often the case for glyphosate. The method is robust, possesses high identification confidence, while being suitable for most commercial and academic laboratories. All leaf samples from five coffee fields analyzed (n=21) contained glyphosate, while AMPA was absent. The simplified clean-up procedure was successfully validated for coffee leaves, rice, black beans and river water. Copyright © 2015 Elsevier B.V. All rights reserved.
Bhatt, Vinod; Sharma, Sushila; Kumar, Neeraj; Sharma, Upendra; Singh, Bikram
2017-01-05
The current study presents isolation and characterization of twelve compounds including catechin (1), isovitexin (2), hesperidin (3), psoralin (4), eudesmin (5), kobusin (6), fargesin (7), sesamin (8), asarinin (9), planispine-A (10), α-sanshool (11) and vitexin (12), from the leaves of Zanthoxylum armatum. Further, two rapid and simple ultra performance liquid chromatography-diode array detection (UPLC-DAD) methods were developed for the simultaneous quantitative determination of isolated compounds from Z. armatum leaves. These analytical methods were validated for linearity, precision, accuracy, limit of detection (LOD) and limit of quantification (LOQ). The LOD and LOQ were in the range of 0.06-0.21μg/mL and 0.19-0.69μg/mL, respectively. The validated method was linear (R 2 ≥0.9906), precise in terms of peak area (intra-day RSDs <3.8% and inter-day RSDs <2.7%), and accurate (109.6-92.5%). This is the first report on the isolation and quantification of 1, 2, 4 and 12 in Z. armatum and 3 in Zanthoxylum genus. The methods: were successfully applied to assess the quality of samples collected from different locations of Himachal Pradesh during summer and winter season. The results demonstrated that flavonoids and furofuran lignans were the major constituents in Z. armatum leaves. The developed methods: were further applied for tandem electrospray ionization-mass spectrometry (UPLC-DAD-ESI-MS/MS) and total eighteen compounds were identified including phenolic acid, flavonoids, furofuran lignans, coumarin and isobutyl amides. Copyright © 2016 Elsevier B.V. All rights reserved.
Paul, Atish T; Vir, Sanjay; Bhutani, K K
2008-10-24
A new liquid chromatography-mass spectrometry (LC-MS)-based method coupled with pressurized liquid extraction (PLE) as an efficient sample preparation technique has been developed for the quantification and fingerprint analysis of Solanum xanthocarpum. Optimum separations of the samples were achieved on a Waters MSC-18 XTerra column, using 0.5% (v/v) formic acid in water (A) and acetonitrile (ACN):2-propanol:formic acid (94.5:5:0.5, v/v/v) (B) as mobile phase. The separation was carried out using linear gradient elution with a flow rate of 1.0mL/min. The gradient was: 0min, 20% B; 14min, 30% B; 20min, 30% B; 27min, 60% B and the column was re-equilibrated to the initial condition (20% B) for 10min prior to next injection. The steroidal glycoalkaloids (SGAs) which are the major active constituents were isolated as pure compounds from the crude methanolic extract of S. xanthocarpum by preparative LC-MS and after characterization were used as external standards for the development and validation of the method. Extracts prepared by conventional Soxhlet extraction, PLE and ultrasonication were used for analysis. The method was validated for repeatability, precision (intra- and inter-day variation), accuracy (recovery) and sensitivity (limit of detection and limit of quantitation). The purpose of the work was to develop a validated method, which can be used for the quantification of SGAs in commercialized S. xanthocarpum products and the fingerprint analysis for their routine quality control.
Laboureur, Laurent; Guérineau, Vincent; Auxilien, Sylvie; Yoshizawa, Satoko; Touboul, David
2018-02-16
A method based on supercritical fluid chromatography coupled to high resolution mass spectrometry for the profiling of canonical and modified nucleosides was optimized, and compared to classical reverse-phase liquid chromatography in terms of separation, number of detected modified nucleosides and sensitivity. Limits of detection and quantification were measured using statistical method and quantifications of twelve nucleosides of a tRNA digest from E. coli are in good agreement with previously reported data. Results highlight the complementarity of both separation techniques to cover the largest view of nucleoside modifications for forthcoming epigenetic studies. Copyright © 2017 Elsevier B.V. All rights reserved.
Al Feteisi, Hajar; Achour, Brahim; Rostami-Hodjegan, Amin; Barber, Jill
2015-01-01
Drug-metabolizing enzymes and transporters play an important role in drug absorption, distribution, metabolism and excretion and, consequently, they influence drug efficacy and toxicity. Quantification of drug-metabolizing enzymes and transporters in various tissues is therefore essential for comprehensive elucidation of drug absorption, distribution, metabolism and excretion. Recent advances in liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) have improved the quantification of pharmacologically relevant proteins. This report presents an overview of mass spectrometry-based methods currently used for the quantification of drug-metabolizing enzymes and drug transporters, mainly focusing on applications and cost associated with various quantitative strategies based on stable isotope-labeled standards (absolute quantification peptide standards, quantification concatemers, protein standards for absolute quantification) and label-free analysis. In mass spectrometry, there is no simple relationship between signal intensity and analyte concentration. Proteomic strategies are therefore complex and several factors need to be considered when selecting the most appropriate method for an intended application, including the number of proteins and samples. Quantitative strategies require appropriate mass spectrometry platforms, yet choice is often limited by the availability of appropriate instrumentation. Quantitative proteomics research requires specialist practical skills and there is a pressing need to dedicate more effort and investment to training personnel in this area. Large-scale multicenter collaborations are also needed to standardize quantitative strategies in order to improve physiologically based pharmacokinetic models.
NASA Astrophysics Data System (ADS)
Guo, Zijian; Favazza, Christopher; Garcia-Uribe, Alejandro; Wang, Lihong V.
2012-06-01
Photoacoustic (PA) microscopy (PAM) can image optical absorption contrast with ultrasonic spatial resolution in the optical diffusive regime. Conventionally, accurate quantification in PAM requires knowledge of the optical fluence attenuation, acoustic pressure attenuation, and detection bandwidth. We circumvent this requirement by quantifying the optical absorption coefficients from the acoustic spectra of PA signals acquired at multiple optical wavelengths. With the acoustic spectral method, the absorption coefficients of an oxygenated bovine blood phantom at 560, 565, 570, and 575 nm were quantified with errors of <3%. We also quantified the total hemoglobin concentration and hemoglobin oxygen saturation in a live mouse. Compared with the conventional amplitude method, the acoustic spectral method provides greater quantification accuracy in the optical diffusive regime. The limitations of the acoustic spectral method was also discussed.
Guo, Zijian; Favazza, Christopher; Garcia-Uribe, Alejandro
2012-01-01
Abstract. Photoacoustic (PA) microscopy (PAM) can image optical absorption contrast with ultrasonic spatial resolution in the optical diffusive regime. Conventionally, accurate quantification in PAM requires knowledge of the optical fluence attenuation, acoustic pressure attenuation, and detection bandwidth. We circumvent this requirement by quantifying the optical absorption coefficients from the acoustic spectra of PA signals acquired at multiple optical wavelengths. With the acoustic spectral method, the absorption coefficients of an oxygenated bovine blood phantom at 560, 565, 570, and 575 nm were quantified with errors of <3%. We also quantified the total hemoglobin concentration and hemoglobin oxygen saturation in a live mouse. Compared with the conventional amplitude method, the acoustic spectral method provides greater quantification accuracy in the optical diffusive regime. The limitations of the acoustic spectral method was also discussed. PMID:22734767
Guo, Zijian; Favazza, Christopher; Garcia-Uribe, Alejandro; Wang, Lihong V
2012-06-01
Photoacoustic (PA) microscopy (PAM) can image optical absorption contrast with ultrasonic spatial resolution in the optical diffusive regime. Conventionally, accurate quantification in PAM requires knowledge of the optical fluence attenuation, acoustic pressure attenuation, and detection bandwidth. We circumvent this requirement by quantifying the optical absorption coefficients from the acoustic spectra of PA signals acquired at multiple optical wavelengths. With the acoustic spectral method, the absorption coefficients of an oxygenated bovine blood phantom at 560, 565, 570, and 575 nm were quantified with errors of <3%. We also quantified the total hemoglobin concentration and hemoglobin oxygen saturation in a live mouse. Compared with the conventional amplitude method, the acoustic spectral method provides greater quantification accuracy in the optical diffusive regime. The limitations of the acoustic spectral method was also discussed.
Provost, Karine; Leblond, Antoine; Gauthier-Lemire, Annie; Filion, Édith; Bahig, Houda; Lord, Martin
2017-09-01
Planar perfusion scintigraphy with 99m Tc-labeled macroaggregated albumin is often used for pretherapy quantification of regional lung perfusion in lung cancer patients, particularly those with poor respiratory function. However, subdividing lung parenchyma into rectangular regions of interest, as done on planar images, is a poor reflection of true lobar anatomy. New tridimensional methods using SPECT and SPECT/CT have been introduced, including semiautomatic lung segmentation software. The present study evaluated inter- and intraobserver agreement on quantification using SPECT/CT software and compared the results for regional lung contribution obtained with SPECT/CT and planar scintigraphy. Methods: Thirty lung cancer patients underwent ventilation-perfusion scintigraphy with 99m Tc-macroaggregated albumin and 99m Tc-Technegas. The regional lung contribution to perfusion and ventilation was measured on both planar scintigraphy and SPECT/CT using semiautomatic lung segmentation software by 2 observers. Interobserver and intraobserver agreement for the SPECT/CT software was assessed using the intraclass correlation coefficient, Bland-Altman plots, and absolute differences in measurements. Measurements from planar and tridimensional methods were compared using the paired-sample t test and mean absolute differences. Results: Intraclass correlation coefficients were in the excellent range (above 0.9) for both interobserver and intraobserver agreement using the SPECT/CT software. Bland-Altman analyses showed very narrow limits of agreement. Absolute differences were below 2.0% in 96% of both interobserver and intraobserver measurements. There was a statistically significant difference between planar and SPECT/CT methods ( P < 0.001) for quantification of perfusion and ventilation for all right lung lobes, with a maximal mean absolute difference of 20.7% for the right middle lobe. There was no statistically significant difference in quantification of perfusion and ventilation for the left lung lobes using either method; however, absolute differences reached 12.0%. The total right and left lung contributions were similar for the two methods, with a mean difference of 1.2% for perfusion and 2.0% for ventilation. Conclusion: Quantification of regional lung perfusion and ventilation using SPECT/CT-based lung segmentation software is highly reproducible. This tridimensional method yields statistically significant differences in measurements for right lung lobes when compared with planar scintigraphy. We recommend that SPECT/CT-based quantification be used for all lung cancer patients undergoing pretherapy evaluation of regional lung function. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.
Lee, Bai Qin; Wan Mohamed Radzi, Che Wan Jasimah Bt; Khor, Sook Mei
2016-02-05
This paper reports the application of hexamethyldisilazane-trimethylsilyl trifluoromethanesulfonate (HMDS-TMSOTf) for the simultaneous silylation of 3-monochloro-1,2-propanediol (3-MCPD) and 1,3-dicholoropropanol (1,3-DCP) in solid and liquid food samples. 3-MCPD and 1,3-DCP are chloropropanols that have been established as Group 2B carcinogens in clinical testing. They can be found in heat-processed food, especially when an extended high-temperature treatment is required. However, the current AOAC detection method is time-consuming and expensive. Thus, HMDS-TMSOTf was used in this study to provide a safer, and cost-effective alternative to the HFBI method. Three important steps are involved in the quantification of 3-MCPD and 1,3-DCP: extraction, derivatization and quantification. The optimization of the derivatization process, which involved focusing on the catalyst volume, derivatization temperature, and derivatization time was performed based on the findings obtained from both the Box-Behnken modeling and a real experimental set up. With the optimized conditions, the newly developed method was used for actual food sample quantification and the results were compared with those obtained via the standard AOAC method. The developed method required less samples and reagents but it could be used to achieve lower limits of quantification (0.0043mgL(-1) for 1,3-DCP and 0.0011mgL(-1) for 3-MCPD) and detection (0.0028mgL(-1) for 1,3-DCP and 0.0008mgL(-1) for 3-MCPD). All the detected concentrations are below the maximum tolerable limit of 0.02mgL(-1). The percentage of recovery obtained from food sample analysis was between 83% and 96%. The new procedure was validated with the AOAC method and showed a comparable performance. The HMDS-TMSOTf derivatization strategy is capable of simultaneously derivatizing 1,3-DCP and 3-MCPD at room temperature, and it also serves as a rapid, sensitive, and accurate analytical method for food samples analysis. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Rajendraprasad, N.; Basavaiah, K.
2016-07-01
Oxfendazole (OFA) is a broad spectrum benzimidazole anthelmintic medication used to treat veterinary diseases. Two new, simple, rapid, precise and accurate, and sensitive spectrophotometric methods have been developed and validated for the assay of OFA in its pure form and in its boluses. The first method (method A) is based on the measurement of green colored manganate obtained due to oxidation of OFA by permanganate in an alkaline medium at 610 nm. In the second method (Method B), the chromophoric activity of OFA is measured at 290 nm in the acetic acid-water (1:1) solvent system. OFA has been quantified over the linear ranges of 1.25-12.5 and 1.25-10 μg/mL in method A and method B, respectively, with apparent molar absorptivity values of 2.54 × 104 and 2.13 × 104 L·mol-1·cm-1. The limit of detection (LOD), limit of quantification (LOQ), and Sandell sensitivity values are 0.15 u 0.18 μg/mL, 0.46 and 0.56 μg/mL, and 0.0124 and 0.0148 μg/cm2. The developed methods were successfully applied to determine OFA in the bolus. No interference from adjuvants was observed.
Wang, Wentao; Meng, Bingjun; Lu, Xiaoxia; Liu, Yu; Tao, Shu
2007-10-29
The methods of simultaneous extraction of polycyclic aromatic hydrocarbons (PAHs) and organochlorine pesticides (OCPs) from soils using Soxhlet extraction, microwave-assisted extraction (MAE) and accelerated solvent extraction (ASE) were established, and the extraction efficiencies using the three methods were systemically compared from procedural blank, limits of detection and quantification, method recovery and reproducibility, method chromatogram and other factors. In addition, soils with different total organic carbon contents were used to test the extraction efficiencies of the three methods. The results showed that the values obtained in this study were comparable with the values reported by other studies. In some respects such as method recovery and reproducibility, there were no significant differences among the three methods for the extraction of PAHs and OCPs. In some respects such as procedural blank and limits of detection and quantification, there were significant differences among the three methods. Overall, ASE had the best extraction efficiency compared to MAE and Soxhlet extraction, and the extraction efficiencies of MAE and Soxhlet extraction were comparable to each other depending on the property such as TOC content of the studied soil. Considering other factors such as solvent consumption and extraction time, ASE and MAE are preferable to Soxhlet extraction.
Sánchez-Guijo, Alberto; Oji, Vinzenz; Hartmann, Michaela F; Traupe, Heiko; Wudy, Stefan A
2015-09-01
Steroids are primarily present in human fluids in their sulfated forms. Profiling of these compounds is important from both diagnostic and physiological points of view. Here, we present a novel method for the quantification of 11 intact steroid sulfates in human serum by LC-MS/MS. The compounds analyzed in our method, some of which are quantified for the first time in blood, include cholesterol sulfate, pregnenolone sulfate, 17-hydroxy-pregnenolone sulfate, 16-α-hydroxy-dehydroepiandrosterone sulfate, dehydroepiandrosterone sulfate, androstenediol sulfate, androsterone sulfate, epiandrosterone sulfate, testosterone sulfate, epitestosterone sulfate, and dihydrotestosterone sulfate. The assay was conceived to quantify sulfated steroids in a broad range of concentrations, requiring only 300 μl of serum. The method has been validated and its performance was studied at three quality controls, selected for each compound according to its physiological concentration. The assay showed good linearity (R(2) > 0.99) and recovery for all the compounds, with limits of quantification ranging between 1 and 80 ng/ml. Averaged intra-day and between-day precisions (coefficient of variation) and accuracies (relative errors) were below 10%. The method has been successfully applied to study the sulfated steroidome in diseases such as steroid sulfatase deficiency, proving its diagnostic value. This is, to our best knowledge, the most comprehensive method available for the quantification of sulfated steroids in human blood. Copyright © 2015 by the American Society for Biochemistry and Molecular Biology, Inc.
Gasperotti, Mattia; Masuero, Domenico; Guella, Graziano; Mattivi, Fulvio; Vrhovsek, Urska
2014-10-01
An increasing number of studies have concerned the profiling of polyphenol microbial metabolites, especially in urine or plasma, but only a few have regarded their accurate quantification. This study reports on a new ultra-performance liquid chromatography tandem mass spectrometry method with electrospray ionisation (UHPLC-ESI-MS/MS) using a simple clean-up step with solid phase extraction (SPE) and validation on different biological matrices. The method was tested with spiked samples of liver, heart, kidneys, brain, blood and urine. The purification procedure, after the evaluation of three different cartridges, makes it possible to obtain cleaner samples and better quantification of putative trace metabolites, especially related to dietary studies, with concentrations below ng/g in tissue and for urine and blood, starting from ng/ml. Limits of detection and linear range were also assessed using mixed polyphenol metabolite standards. Short chromatographic separation was carried out for 23 target compounds related to the polyphenol microbial metabolism, coupled with a triple quadrupole mass spectrometer for their accurate quantification. By analysing different spiked biological samples we were able to test metabolite detection in the matrix and validate the overall recovery of the method, from purification to quantification. The method developed can be successfully applied and is suitable for high-throughput targeted metabolomics analysis related to nutritional intervention, or the study of the metabolic mechanism in response to a polyphenol-rich diet. Copyright © 2014 Elsevier B.V. All rights reserved.
Computer-aided Assessment of Regional Abdominal Fat with Food Residue Removal in CT
Makrogiannis, Sokratis; Caturegli, Giorgio; Davatzikos, Christos; Ferrucci, Luigi
2014-01-01
Rationale and Objectives Separate quantification of abdominal subcutaneous and visceral fat regions is essential to understand the role of regional adiposity as risk factor in epidemiological studies. Fat quantification is often based on computed tomography (CT) because fat density is distinct from other tissue densities in the abdomen. However, the presence of intestinal food residues with densities similar to fat may reduce fat quantification accuracy. We introduce an abdominal fat quantification method in CT with interest in food residue removal. Materials and Methods Total fat was identified in the feature space of Hounsfield units and divided into subcutaneous and visceral components using model-based segmentation. Regions of food residues were identified and removed from visceral fat using a machine learning method integrating intensity, texture, and spatial information. Cost-weighting and bagging techniques were investigated to address class imbalance. Results We validated our automated food residue removal technique against semimanual quantifications. Our feature selection experiments indicated that joint intensity and texture features produce the highest classification accuracy at 95%. We explored generalization capability using k-fold cross-validation and receiver operating characteristic (ROC) analysis with variable k. Losses in accuracy and area under ROC curve between maximum and minimum k were limited to 0.1% and 0.3%. We validated tissue segmentation against reference semimanual delineations. The Dice similarity scores were as high as 93.1 for subcutaneous fat and 85.6 for visceral fat. Conclusions Computer-aided regional abdominal fat quantification is a reliable computational tool for large-scale epidemiological studies. Our proposed intestinal food residue reduction scheme is an original contribution of this work. Validation experiments indicate very good accuracy and generalization capability. PMID:24119354
USDA-ARS?s Scientific Manuscript database
Quantitative PCR (qPCR) can be used to detect and monitor pathogen colonization, but early attempts to apply the technology to Botrytis cinerea infection of grape berries have identified limitations to current techniques. In this study, four DNA extraction methods, two grinding methods, two grape or...
Hashim, Suzana; Beh, Hooi Kheng; Hamil, Mohamad Shahrul Ridzuan; Ismail, Zhari; Majid, Amin Malik Shah Abdul
2016-01-01
Orthosiphon stamineus is a medicinal herb widely grown in Southeast Asia and tropical countries. It has been used traditionally as a diuretic, abdominal pain, kidney and bladder inflammation, gout, and hypertension. This study aims to develop and validate the high-performance thin layer chromatography (HPTLC) method for quantification of rosmarinic acid (RA), 3'-hydroxy-5,6,7,4'-tetramethoxyflavone (TMF), sinensitin (SIN) and eupatorin (EUP) found in ethanol, 50% ethanol and water extract of O. stamineus leaves. HPTLC method was conducted using an HPTLC system with a developed mobile phase system of toluene: ethyl acetate: formic acid (3:7:0.1) performed on precoated silica gel 60 F254 TLC plates. The method was validated based on linearity, accuracy, precision, limit of detection, limit of quantification (LOQ), and specificity, respectively. The detection of spots was observed at ultraviolet 254 nm and 366 nm. The linearity of RA, TMF, SIN, and EUP were obtained between 10 and 100 ng/spot with high correlation coefficient value (R 2 ) of more than 0.986. The limit of detection was found to be 122.47 ± 3.95 (RA), 43.38 ± 0.79 (SIN), 17.26 ± 1.16 (TMF), and 46.80 ± 1.33 ng/spot (EUP), respectively. Whereas the LOQ was found to be 376.44 ± 6.70 (RA), 131.45 ± 2.39 (SIN), 52.30 ± 2.01 (TMF), and 141.82 ± 1.58 ng/spot (EUP), respectively. The proposed method showed good linearity, precision, accuracy, and high sensitivity. Hence, it may be applied in a routine quantification of RA, SIN, TMF, and EUP found in ethanol, 50% of ethanol and water extract of O. stamineus leaves. HPTLC method provides rapid estimation of the marker compound for routine quality control analysis.The established HPTLC method is rapid for qualitative and quantitative fingerprinting of Orthosiphon stamineus extract used for commercial product.Four identified markers (RA, SIN, EUP and TMF) found in three a different type of O. stamineus extracts specifically ethanol, 50% ethanol and water extract were successfully quantified using HPTLC method. Abbreviations Used : HPTLC: High-performance thin layer chromatography; RA: Rosmarinic acid; TMF: 3'-hydroxy-5,6,7,4'-tetramethoxyflavone; SIN: Sinensitin; EUP: Eupatorin; E: Ethanol; EW: 50% ethanol; W: Water; BK: Batu Kurau; KB: Kepala Batas; S: Sik; CJ: Changkat Jering; SB: Sungai Buloh.
Miranda, Nahieh Toscano; Sequinel, Rodrigo; Hatanaka, Rafael Rodrigues; de Oliveira, José Eduardo; Flumignan, Danilo Luiz
2017-04-01
Benzene, toluene, ethylbenzene, and xylenes are some of the most hazardous constituents found in commercial gasoline samples; therefore, these components must be monitored to avoid toxicological problems. We propose a new routine method of ultrafast gas chromatography coupled to flame ionization detection for the direct determination of benzene, toluene, ethylbenzene, and xylenes in commercial gasoline. This method is based on external standard calibration to quantify each compound, including the validation step of the study of linearity, detection and quantification limits, precision, and accuracy. The time of analysis was less than 3.2 min, with quantitative statements regarding the separation and quantification of all compounds in commercial gasoline samples. Ultrafast gas chromatography is a promising alternative method to official analytical techniques. Government laboratories could consider using this method for quality control. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Sobhanardakani, S; Farmany, A; Abbasi, S; Cheraghi, J; Hushmandfar, R
2013-03-01
A new kinetic method has been developed for the determination of nitrite in fruit juice samples. The method is based on the catalytic effect of nitrite with the oxidation of Nile Blue A (NBA) by KBrO(3) in the sulfuric acid medium. The optimum conditions obtained are 1.2 mM sulfuric acid, 0.034 mM of NBA, 2.8 × 10(-3) M KBrO(3), reaction temperature of 20 °C, and reaction time of 100 s at 595.5 nm. Under the optimized conditions, the method allowed the quantification of nitrite in a range of 0.2-800 μg/mL with a detection limit of 0.02 μg/mL. The method was applied to the determination of nitrite in 15 brands of fruit juice samples.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oostrom, Mart; Dane, J. H.; Wietsma, Thomas W.
2007-08-01
A review is presented of original multidimensional, intermediate-scale experiments involving non-aqueous phase liquid (NAPL) flow behavior, imaging, and detection/quantification with solute tracers. In a companion paper (Oostrom, M., J.H. Dane, and T.W. Wietsma. 2006. A review of multidimensional, multifluid intermediate-scale experiments: Nonaqueous phase dissolution and enhanced remediation. Vadose Zone Journal 5:570-598) experiments related to aqueous dissolution and enhanced remediation were discussed. The experiments investigating flow behavior include infiltration and redistribution experiments with both light and dense NAPLs in homogeneous and heterogeneous porous medium systems. The techniques used for NAPL saturation mapping for intermediate-scale experiments include photon-attenuation methods such as gammamore » and X-ray techniques, and photographic methods such as the light reflection, light transmission, and multispectral image analysis techniques. Solute tracer methods used for detection and quantification of NAPL in the subsurface are primarily limited to variations of techniques comparing the behavior of conservative and partitioning tracers. Besides a discussion of the experimental efforts, recommendations for future research at this laboratory scale are provided.« less
Integrative analysis with ChIP-seq advances the limits of transcript quantification from RNA-seq
Liu, Peng; Sanalkumar, Rajendran; Bresnick, Emery H.; Keleş, Sündüz; Dewey, Colin N.
2016-01-01
RNA-seq is currently the technology of choice for global measurement of transcript abundances in cells. Despite its successes, isoform-level quantification remains difficult because short RNA-seq reads are often compatible with multiple alternatively spliced isoforms. Existing methods rely heavily on uniquely mapping reads, which are not available for numerous isoforms that lack regions of unique sequence. To improve quantification accuracy in such difficult cases, we developed a novel computational method, prior-enhanced RSEM (pRSEM), which uses a complementary data type in addition to RNA-seq data. We found that ChIP-seq data of RNA polymerase II and histone modifications were particularly informative in this approach. In qRT-PCR validations, pRSEM was shown to be superior than competing methods in estimating relative isoform abundances within or across conditions. Data-driven simulations suggested that pRSEM has a greatly decreased false-positive rate at the expense of a small increase in false-negative rate. In aggregate, our study demonstrates that pRSEM transforms existing capacity to precisely estimate transcript abundances, especially at the isoform level. PMID:27405803
CONDUCTING-POLYMER NANOWIRE IMMUNOSENSOR ARRAYS FOR MICROBIAL PATHOGENS
The lack of methods for routine rapid and sensitive detection and quantification of specific pathogens has limited the amount of information available on their occurrence in drinking water and other environmental samples. The nanowire biosensor arrays developed in this study w...
Kim, Min Kyung; Yang, Dong-Hyug; Jung, Mihye; Jung, Eun Ha; Eom, Han Young; Suh, Joon Hyuk; Min, Jung Won; Kim, Unyong; Min, Hyeyoung; Kim, Jinwoong; Han, Sang Beom
2011-09-16
Methods using high performance liquid chromatography with diode array detection (HPLC-DAD) and tandem mass spectrometry (HPLC-MS/MS) were developed and validated for the simultaneous determination of 5 chromones and 6 coumarins: prim-O-glucosylcimifugin (1), cimifugin (2), nodakenin (3), 4'-O-β-d-glucosyl-5-O-methylvisamminol (4), sec-O-glucosylhamaudol (5), psoralen (6), bergapten (7), imperatorin (8), phellopterin (9), 3'-O-angeloylhamaudol (10) and anomalin (11), in Radix Saposhnikoviae. The separation conditions for HPLC-DAD were optimized using an Ascentis Express C18 (4.6 mm×100 mm, 2.7 μm particle size) fused-core column. The mobile phase was composed of 10% aqueous acetonitrile (A) and 90% acetonitrile (B) and the elution was performed under a gradient mode at a flow rate of 1.0 mL/min. The detection wavelength was set at 300 nm. The HPLC-DAD method yielded a base line separation of the 11 components in 50% methanol extract of Radix Saposhnikoviae with no interfering peaks detected. The HPLC-DAD method was validated in terms of linearity, accuracy and precision (intra- and inter-day), limit of quantification (LOQ), recovery, and robustness. Specific determination of the 11 components was also accomplished by a triple quadrupole tandem mass spectrometer equipped with an electrospray ionization (ESI) source. This HPLC-MS/MS method was also validated by determining the linearity, limit of quantification, accuracy, and precision. Quantification of the 11 components in 51 commercial Radix Saposhnikoviae samples was successfully performed using the developed HPLC-DAD method. The identity, batch-to-batch consistency, and authenticity of Radix Saposhnikoviae were successfully monitored by the proposed HPLC-DAD and HPLC-MS/MS methods. Copyright © 2011 Elsevier B.V. All rights reserved.
Ens, Waldemar; Senner, Frank; Gygax, Benjamin; Schlotterbeck, Götz
2014-05-01
A new method for the simultaneous determination of iodated X-ray contrast media (ICM) and artificial sweeteners (AS) by liquid chromatography-tandem mass spectrometry (LC-MS/MS) operated in positive and negative ionization switching mode was developed. The method was validated for surface, ground, and drinking water samples. In order to gain higher sensitivities, a 10-fold sample enrichment step using a Genevac EZ-2 plus centrifugal vacuum evaporator that provided excellent recoveries (90 ± 6 %) was selected for sample preparation. Limits of quantification below 10 ng/L were obtained for all compounds. Furthermore, sample preparation recoveries and matrix effects were investigated thoroughly for all matrix types. Considerable matrix effects were observed in surface water and could be compensated by the use of four stable isotope-labeled internal standards. Due to their persistence, fractions of diatrizoic acid, iopamidol, and acesulfame could pass the whole drinking water production process and were observed also in drinking water. To monitor the fate and occurrence of these compounds, the validated method was applied to samples from different stages of the drinking water production process of the Industrial Works of Basel (IWB). Diatrizoic acid was found as the most persistent compound which was eliminated by just 40 % during the whole drinking water treatment process, followed by iopamidol (80 % elimination) and acesulfame (85 % elimination). All other compounds were completely restrained and/or degraded by the soil and thus were not detected in groundwater. Additionally, a direct injection method without sample preparation achieving 3-20 ng/L limits of quantification was compared to the developed method.
In vivo behavior of NTBI revealed by automated quantification system.
Ito, Satoshi; Ikuta, Katsuya; Kato, Daisuke; Lynda, Addo; Shibusa, Kotoe; Niizeki, Noriyasu; Toki, Yasumichi; Hatayama, Mayumi; Yamamoto, Masayo; Shindo, Motohiro; Iizuka, Naomi; Kohgo, Yutaka; Fujiya, Mikihiro
2016-08-01
Non-Tf-bound iron (NTBI), which appears in serum in iron overload, is thought to contribute to organ damage; the monitoring of serum NTBI levels may therefore be clinically useful in iron-overloaded patients. However, NTBI quantification methods remain complex, limiting their use in clinical practice. To overcome the technical difficulties often encountered, we recently developed a novel automated NTBI quantification system capable of measuring large numbers of samples. In the present study, we investigated the in vivo behavior of NTBI in human and animal serum using this newly established automated system. Average NTBI in healthy volunteers was 0.44 ± 0.076 μM (median 0.45 μM, range 0.28-0.66 μM), with no significant difference between sexes. Additionally, serum NTBI rapidly increased after iron loading, followed by a sudden disappearance. NTBI levels also decreased in inflammation. The results indicate that NTBI is a unique marker of iron metabolism, unlike other markers of iron metabolism, such as serum ferritin. Our new automated NTBI quantification method may help to reveal the clinical significance of NTBI and contribute to our understanding of iron overload.
Ullrich, Sebastian; Neef, Sylvia K; Schmarr, Hans-Georg
2018-02-01
Low-molecular-weight volatile sulfur compounds such as thiols, sulfides, disulfides as well as thioacetates cause a sulfidic off-flavor in wines even at low concentration levels. The proposed analytical method for quantification of these compounds in wine is based on headspace solid-phase microextraction, followed by gas chromatographic analysis with sulfur-specific detection using a pulsed flame photometric detector. Robust quantification was achieved via a stable isotope dilution assay using commercial and synthesized deuterated isotopic standards. The necessary chromatographic separation of analytes and isotopic standards benefits from the inverse isotope effect realized on an apolar polydimethylsiloxane stationary phase of increased film thickness. Interferences with sulfur-specific detection in wine caused by sulfur dioxide were minimized by addition of propanal. The method provides adequate validation data, with good repeatability and limits of detection and quantification. It suits the requirements of wine quality management, allowing the control of oenological treatments to counteract an eventual formation of excessively high concentration of such malodorous compounds. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Quintelas, Cristina; Mesquita, Daniela P; Lopes, João A; Ferreira, Eugénio C; Sousa, Clara
2015-08-15
Accurate detection and quantification of microbiological contaminations remains an issue mainly due the lack of rapid and precise analytical techniques. Standard methods are expensive and time-consuming being associated to high economic losses and public health threats. In the context of pharmaceutical industry, the development of fast analytical techniques able to overcome these limitations is crucial and spectroscopic techniques might constitute a reliable alternative. In this work we proved the ability of Fourier transform near infrared spectroscopy (FT-NIRS) to detect and quantify bacteria (Bacillus subtilis, Escherichia coli, Pseudomonas fluorescens, Salmonella enterica, Staphylococcus epidermidis) from 10 to 10(8) CFUs/mL in sterile saline solutions (NaCl 0.9%). Partial least squares discriminant analysis (PLSDA) models showed that FT-NIRS was able to discriminate between sterile and contaminated solutions for all bacteria as well as to identify the contaminant bacteria. Partial least squares (PLS) models allowed bacterial quantification with limits of detection ranging from 5.1 to 9 CFU/mL for E. coli and B. subtilis, respectively. This methodology was successfully validated in three pharmaceutical preparations (contact lens solution, cough syrup and topic anti-inflammatory solution) proving that this technique possess a high potential to be routinely used for the detection and quantification of bacterial contaminations. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Gallardo Estrella, L.; van Ginneken, B.; van Rikxoort, E. M.
2013-03-01
Chronic Obstructive Pulmonary Disease (COPD) is a lung disease characterized by progressive air flow limitation caused by emphysema and chronic bronchitis. Emphysema is quantified from chest computed tomography (CT) scans as the percentage of attentuation values below a fixed threshold. The emphysema quantification varies substantially between scans reconstructed with different kernels, limiting the possibilities to compare emphysema quantifications obtained from scans with different reconstruction parameters. In this paper we propose a method to normalize scans reconstructed with different kernels to have the same characteristics as scans reconstructed with a reference kernel and investigate if this normalization reduces the variability in emphysema quantification. The proposed normalization splits a CT scan into different frequency bands based on hierarchical unsharp masking. Normalization is performed by changing the energy in each frequency band to the average energy in each band in the reference kernel. A database of 15 subjects with COPD was constructed for this study. All subjects were scanned at total lung capacity and the scans were reconstructed with four different reconstruction kernels. The normalization was applied to all scans. Emphysema quantification was performed before and after normalization. It is shown that the emphysema score varies substantially before normalization but the variation diminishes after normalization.
Kneisel, Stefan; Speck, Michael; Moosmann, Bjoern; Corneillie, Todd M; Butlin, Nathaniel G; Auwärter, Volker
2013-05-01
Serum and urine samples are commonly used for the analysis of synthetic cannabinoids in biofluids; however, their utilization as analytical matrices for drug abstinence control features some substantial drawbacks. While for blood collection invasive sampling is inevitable, the urinary analysis of synthetic cannabinoids is limited by the lack of available reference standards of the respective major metabolites. Moreover, the long detectability of synthetic cannabinoids in both matrices hampers the identification of a recent synthetic cannabinoid use. This article describes the development, validation and application of an LC/ESI-MS/MS method for the quantification of 28 synthetic cannabinoids in neat oral fluid (OF) samples. OF samples were prepared by protein precipitation using ice-cold acetonitrile. Chromatographic separation was achieved by gradient elution on a Luna Phenyl Hexyl column (50 × 2 mm, 5 μm), while detection was carried out on a QTrap 4000 instrument in positive ionization mode. The limits of detection ranged from 0.02 to 0.40 ng/mL, whereas the lower limits of quantification ranged from 0.2 to 4.0 ng/mL. The method was applied to authentic samples collected during two preliminary studies in order to obtain insights into the general detectability and detection windows of synthetic cannabinoids in this matrix. The results indicate that synthetic cannabinoids are transferred from the blood stream into OF and vice versa only at a very low rate. Therefore, positive OF samples are due to contamination of the oral cavity during smoking. As these drug-contaminations could be detected up to approximately 2 days, neat oral fluid appears to be well suited for detection of a recent synthetic cannabinoid use.
MPQ-cytometry: a magnetism-based method for quantification of nanoparticle-cell interactions
NASA Astrophysics Data System (ADS)
Shipunova, V. O.; Nikitin, M. P.; Nikitin, P. I.; Deyev, S. M.
2016-06-01
Precise quantification of interactions between nanoparticles and living cells is among the imperative tasks for research in nanobiotechnology, nanotoxicology and biomedicine. To meet the challenge, a rapid method called MPQ-cytometry is developed, which measures the integral non-linear response produced by magnetically labeled nanoparticles in a cell sample with an original magnetic particle quantification (MPQ) technique. MPQ-cytometry provides a sensitivity limit 0.33 ng of nanoparticles and is devoid of a background signal present in many label-based assays. Each measurement takes only a few seconds, and no complicated sample preparation or data processing is required. The capabilities of the method have been demonstrated by quantification of interactions of iron oxide nanoparticles with eukaryotic cells. The total amount of targeted nanoparticles that specifically recognized the HER2/neu oncomarker on the human cancer cell surface was successfully measured, the specificity of interaction permitting the detection of HER2/neu positive cells in a cell mixture. Moreover, it has been shown that MPQ-cytometry analysis of a HER2/neu-specific iron oxide nanoparticle interaction with six cell lines of different tissue origins quantitatively reflects the HER2/neu status of the cells. High correlation of MPQ-cytometry data with those obtained by three other commonly used in molecular and cell biology methods supports consideration of this method as a prospective alternative for both quantifying cell-bound nanoparticles and estimating the expression level of cell surface antigens. The proposed method does not require expensive sophisticated equipment or highly skilled personnel and it can be easily applied for rapid diagnostics, especially under field conditions.Precise quantification of interactions between nanoparticles and living cells is among the imperative tasks for research in nanobiotechnology, nanotoxicology and biomedicine. To meet the challenge, a rapid method called MPQ-cytometry is developed, which measures the integral non-linear response produced by magnetically labeled nanoparticles in a cell sample with an original magnetic particle quantification (MPQ) technique. MPQ-cytometry provides a sensitivity limit 0.33 ng of nanoparticles and is devoid of a background signal present in many label-based assays. Each measurement takes only a few seconds, and no complicated sample preparation or data processing is required. The capabilities of the method have been demonstrated by quantification of interactions of iron oxide nanoparticles with eukaryotic cells. The total amount of targeted nanoparticles that specifically recognized the HER2/neu oncomarker on the human cancer cell surface was successfully measured, the specificity of interaction permitting the detection of HER2/neu positive cells in a cell mixture. Moreover, it has been shown that MPQ-cytometry analysis of a HER2/neu-specific iron oxide nanoparticle interaction with six cell lines of different tissue origins quantitatively reflects the HER2/neu status of the cells. High correlation of MPQ-cytometry data with those obtained by three other commonly used in molecular and cell biology methods supports consideration of this method as a prospective alternative for both quantifying cell-bound nanoparticles and estimating the expression level of cell surface antigens. The proposed method does not require expensive sophisticated equipment or highly skilled personnel and it can be easily applied for rapid diagnostics, especially under field conditions. Electronic supplementary information (ESI) available. See DOI: 10.1039/c6nr03507h
Peng, Bo; Qiao, Chun-Feng; Zhao, Jing; Huang, Wei-Hua; Hu, De-Jun; Liu, Hua-Gang; Li, Shao-Ping
2013-03-04
A high performance liquid chromatography coupled with diode array and evaporative light scattering detection (HPLC-DAD-ELSD) method for simultaneous determination of eight major bioactive compounds including two flavonoids (rutin and eriodictyol-7-O-β-D-glucopyranoside), two isochlorogenic acids (isochlorogenic acid A and isochlorogenic acid C) and four triterpenoids (ilexhainanoside D, ilexsaponin A1, ilexgenin A and ursolic acid) in Ilex hainanensis has been developed for the first time. The 283 nm wavelength was chosen for determination of two flavonoids and two isochlorogenic acids. ELSD was applied to determine four triterpenoids. The analysis was performed on an Agilent Zorbax SB-C18 column (250 × 4.6 mm i.d., 5 µm) with gradient elution of 0.2% formic acid in water and acetonitrile. The method was validated for linearity, limit of detection, limit of quantification, precision, repeatability and accuracy. The proposed method has been successfully applied for simultaneous quantification of the analytes in four samples of Ilex hainanensis, which is helpful for quality control of this plant.
Douša, Michal; Srbek, Jan; Rádl, Stanislav; Cerný, Josef; Klecán, Ondřej; Havlíček, Jaroslav; Tkadlecová, Marcela; Pekárek, Tomáš; Gibala, Petr; Nováková, Lucie
2014-06-01
Two new impurities were described and determined using gradient HPLC method with UV detection in retigabine (RET). Using LC-HRMS, NMR and IR analysis the impurities were identified as RET-dimer I: diethyl {4,4'-diamino-6,6'-bis[(4-fluorobenzyl)amino]biphenyl-3,3'-diyl}biscarbamate and RET-dimer II: ethyl {2-amino-5-[{2-amino-4-[(4-fluorobenzyl) amino] phenyl} (ethoxycarbonyl) amino]-4-[(4-fluorobenzyl)amino] phenyl}carbamate. Reference standards of these impurities were synthesized followed by semipreparative HPLC purification. The mechanism of the formation of these impurities is also discussed. An HPLC method was optimized in order to separate, selectively detect and quantify all process-related impurities and degradation products of RET. The presented method, which was validated in terms of linearity, limit of detection (LOD), limit of quantification (LOQ) and selectivity is very quick (less than 11min including re-equilibration time) and therefore highly suitable for routine analysis of RET related substances as well as stability studies. Copyright © 2014 Elsevier B.V. All rights reserved.
Breidi, Salah Eddine; Barker, James; Petróczi, Andrea; Naughton, Declan P
2012-01-01
Gas chromatography-mass spectrometric (GC-MS) methods for drug analysis routinely employ derivatising reagents. The aim of this paper was to develop a method for the analysis of two recreational drugs, delta-9-tetrahydrocannabinol (Δ(9)-THC) and cocaine in hair samples using GC-MS, without prior derivatisation, thus allowing the sample to be reanalysed in its original form. An enzymatic digestion technique was also developed. Ten hair samples, that were known positive for either Δ(9)-THC and/or cocaine, were enzymatically digested, extracted, and then analysed by GC-MS. All samples measured contained Δ(9)-THC and one sample contained cocaine. The limits of detection (LOD) and quantification (LOQ) were 0.02 ng/mg and 0.05 ng/mg, respectively, for cocaine and 0.015 ng/mg and 0.02 ng/mg, respectively, for Δ(9)-THC. The wide detection window, ease of direct analysis by GC-MS, lower detection limits of underivatised samples, and the stability of drugs using this technique may offer an improved method of analysis.
Breidi, Salah Eddine; Barker, James; Petróczi, Andrea; Naughton, Declan P.
2012-01-01
Gas chromatography-mass spectrometric (GC-MS) methods for drug analysis routinely employ derivatising reagents. The aim of this paper was to develop a method for the analysis of two recreational drugs, delta-9-tetrahydrocannabinol (Δ9-THC) and cocaine in hair samples using GC-MS, without prior derivatisation, thus allowing the sample to be reanalysed in its original form. An enzymatic digestion technique was also developed. Ten hair samples, that were known positive for either Δ9-THC and/or cocaine, were enzymatically digested, extracted, and then analysed by GC-MS. All samples measured contained Δ9-THC and one sample contained cocaine. The limits of detection (LOD) and quantification (LOQ) were 0.02 ng/mg and 0.05 ng/mg, respectively, for cocaine and 0.015 ng/mg and 0.02 ng/mg, respectively, for Δ9-THC. The wide detection window, ease of direct analysis by GC-MS, lower detection limits of underivatised samples, and the stability of drugs using this technique may offer an improved method of analysis. PMID:22567573
Saxena, Sushil Kumar; Rangasamy, Rajesh; Krishnan, Anoop A; Singh, Dhirendra P; Uke, Sumedh P; Malekadi, Praveen Kumar; Sengar, Anoop S; Mohamed, D Peer; Gupta, Ananda
2018-09-15
An accurate, reliable and fast multi-residue, multi-class method using ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed and validated for simultaneous determination and quantification of 24 pharmacologically active substances of three different classes (Quinolones including fluoroquinolones, sulphonamides and tetracyclines) in aquaculture shrimps. Sample preparation involves extraction with acetonitrile containing 0.1% formic acid and followed by clean up with n-hexane and 0.1% methanol in water by UPLC-MS/MS within 8 min. The method was validated according to European Commission Decision 2002/657. Acceptable values were obtained for linearity (5-200 μg kg -1 ), specificity, Limit of Quantification (5-10 μg kg -1 ), recovery (between 83 and 100%), repeatability (RSD < 9%), within lab reproducibility (RSD < 15%), reproducibility (RSD ≤ 22%), decision limit (105-116 μg kg -1 ) and detection capability (110-132 μg kg -1 ). The validated method was applied to aquaculture shrimp samples from India. Copyright © 2018 Elsevier Ltd. All rights reserved.
Ares, Ana M; Valverde, Silvia; Bernal, José L; Toribio, Laura; Nozal, María J; Bernal, José
2017-10-01
In this study, a new method has been developed to determine flubendiamide in honey using liquid chromatography coupled to a selective mass spectrometry detector (quadrupole-time-of-flight). An efficient sample treatment involving a solid phase extraction with a C 18 sorbent was proposed (average analyte recoveries were between 94 and 104%). Chromatographic analysis (9min) was performed on a C 18 column (Gemini C 18 , 50×2.0mm, 3µm, 110Å). The mobile phase consisted of water and acetonitrile, with a flow rate of 0.5mL/min in gradient elution mode. The method was fully validated in terms of selectivity, limits of detection and quantification, matrix effect, linearity, trueness and precision. Low limits of detection and quantification were obtained, ranging from 0.1 to 0.2µg/kg and 0.4 to 0.6µg/kg, respectively. The method was applied to analyze flubendiamide in honey from different botanic origins (multifloral, rosemary and heather). Copyright © 2017 Elsevier Ltd. All rights reserved.
Legionella detection by culture and qPCR: Comparing apples and oranges.
Whiley, Harriet; Taylor, Michael
2016-01-01
Legionella spp. are the causative agent of Legionnaire's disease and an opportunistic pathogen of significant public health concern. Identification and quantification from environmental sources is crucial for identifying outbreak origins and providing sufficient information for risk assessment and disease prevention. Currently there are a range of methods for Legionella spp. quantification from environmental sources, but the two most widely used and accepted are culture and real-time polymerase chain reaction (qPCR). This paper provides a review of these two methods and outlines their advantages and limitations. Studies from the last 10 years which have concurrently used culture and qPCR to quantify Legionella spp. from environmental sources have been compiled. 26/28 studies detected Legionella at a higher rate using qPCR compared to culture, whilst only one study detected equivalent levels of Legionella spp. using both qPCR and culture. Aggregating the environmental samples from all 28 studies, 2856/3967 (72%) tested positive for the presence of Legionella spp. using qPCR and 1331/3967 (34%) using culture. The lack of correlation between methods highlights the need to develop an acceptable standardized method for quantification that is sufficient for risk assessment and management of this human pathogen.
NASA Astrophysics Data System (ADS)
Meinikmann, K.; Nützmann, G.; Lewandowski, J.
2015-03-01
Groundwater discharge into lakes (lacustrine groundwater discharge, LGD) can be an important driver of lake eutrophication. Its quantification is difficult for several reasons, and thus often neglected in water and nutrient budgets of lakes. In the present case several methods were applied to determine the expansion of the subsurface catchment, to reveal areas of main LGD and to identify the variability of LGD intensity. Size and shape of the subsurface catchment served as a prerequisite in order to calculate long-term groundwater recharge and thus the overall amount of LGD. Isotopic composition of near-shore groundwater was investigated to validate the quality of catchment delineation in near-shore areas. Heat as a natural tracer for groundwater-surface water interactions was used to find spatial variations of LGD intensity. Via an analytical solution of the heat transport equation, LGD rates were calculated from temperature profiles of the lake bed. The method has some uncertainties, as can be found from the results of two measurement campaigns in different years. The present study reveals that a combination of several different methods is required for a reliable identification and quantification of LGD and groundwater-borne nutrient loads.
Use of heat of adsorption to quantify amorphous content in milled pharmaceutical powders.
Alam, Shamsul; Omar, Mahmoud; Gaisford, Simon
2014-01-01
Isothermal calorimetry operated in gas perfusion mode (IGPC) is often used to quantify the amorphous content of pharmaceutical powders. Typically, the calibration line is constructed using the heat of crystallisation as the sample is exposed to high levels of a plasticising vapour. However, since the physical form to which the amorphous fraction crystallises may be dependent on the presence of any crystalline seed, the calibration line is often seen to be non-linear, especially as the amorphous content of the sample approaches 100% w/w. Redesigning the experiment so that the calibration line is constructed with the heat of adsorption is an alternative approach that, because it is not dependent upon crystallisation to a physical form should ameliorate this problem. The two methods are compared for a model compound, salbutamol sulphate, which forms either a hydrate or an anhydrate depending on the amorphous content. The heat of adsorption method was linear between amorphous contents of 0 and 100% w/w and resulted in a detection limit of 0.3% w/w and a quantification limit of 0.92% w/w. The heat of crystallisation method was linear only between amorphous contents of 0 and 80% w/w and resulted in a detection limit of 1.7% w/w and a quantification limit of 5.28% w/w. Thus, the use of heat of adsorption is shown to be a better method for quantifying amorphous contents to better than 1% w/w. Copyright © 2013 Elsevier B.V. All rights reserved.
Russek, Natanya S; Jensen, Matthew B
2014-03-01
Ischemic stroke is a leading cause of death and disability, and current treatments to limit tissue injury and improve recovery are limited. Cerebral infarction is accompanied by intense brain tissue inflammation involving many inflammatory cell types that may cause both negative and positive effects on outcomes. Many potential neuroprotective and neurorestorative treatments may affect, and be affected by, this inflammatory cell infiltration, so that accurate quantification of this tissue response is needed. We performed a systematic review of histological methods to quantify brain tissue inflammatory cell infiltration after cerebral infarction. We found reports of multiple techniques to quantify different inflammatory cell types. We found no direct comparison studies and conclude that more research is needed to optimize the assessment of this important stroke outcome.
Liu, ChangCai; Liang, LongHui; Xiang, Yu; Yu, HuiLan; Zhou, ShiKun; Xi, HaiLing; Liu, ShiLei; Liu, JingQuan
2015-09-01
Sulfur mustard (HD) adduct to human serum albumin (ALB) at Cys-34 residue has become an important and long-term retrospective biomarker of HD exposure. Here, a novel, sensitive, and convenient approach for retrospective quantification of HD concentration exposed to plasma was established by detection of the HD-ALB adduct using ultra-high pressure liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) with a novel non-isotope internal standard (IS). The HD-ALB adduct was isolated from HD-exposed plasma with blue Sepharose. The adduct was digested with proteinase K to form sulfur-hydroxyethylthioethyl ([S-HETE])-Cys-Pro-Phe tripeptide biomarker. The tripeptide adduct could be directly analyzed by UHPLC-MS/MS without an additional solid phase extraction (SPE), which was considered as a critical procedure in previous methods. The easily available 2-chloroethyl ethylsulfide (2-CEES) as HD surrogate was first reported to be used as IS in place of traditional d8-HD for quantification of HD exposure. Furthermore, 2-CEES was also confirmed to be a good IS alternative for quantification of HD exposure by investigation of product ion spectra for their corresponding tripeptide adducts which exhibited identical MS/MS fragmentation behaviors. The method was found to be linear between 1.00 and 250 ng•mL(-1) HD exposure (R(2)>0.9989) with precision of <4.50% relative standard deviation (%RSD), accuracy range between 96.5% and 114%, and a calculated limit of detection (LOD) of 0.532 ng•mL(-1). The lowest reportable limit (LRL) is 1.00 ng•mL(-1), over seven times lower than that of the previous method. The entire method required only 0.1 mL of plasma sample and took under 7 h without special sample preparation equipment. It is proven to be a sensitive, simple, and rugged method, which is easily applied in international laboratories to improve the capabilities for the analysis of biomedical samples related to verification of the Chemical Weapon Convention (CWC).
Ostry, Vladimir; Malir, Frantisek; Dofkova, Marcela; Skarkova, Jarmila; Pfohl-Leszkowicz, Annie; Ruprich, Jiri
2015-09-10
Ochratoxin A is a nephrotoxic and renal carcinogenic mycotoxin and is a common contaminant of various food commodities. Eighty six kinds of foodstuffs (1032 food samples) were collected in 2011-2013. High-performance liquid chromatography with fluorescence detection was used for ochratoxin A determination. Limit of quantification of the method varied between 0.01-0.2 μg/kg depending on the food matrices. The most exposed population is children aged 4-6 years old. Globally for this group, the maximum ochratoxin A dietary exposure for "average consumer" was estimated at 3.3 ng/kg bw/day (lower bound, considering the analytical values below the limit of quantification as 0) and 3.9 ng/kg bw/day (middle bound, considering the analytical values below the limit of quantification as 1/2 limit of quantification). Important sources of exposure for this latter group include grain-based products, confectionery, meat products and fruit juice. The dietary intake for "high consumers" in the group 4-6 years old was estimated from grains and grain-based products at 19.8 ng/kg bw/day (middle bound), from tea at 12.0 ng/kg bw/day (middle bound) and from confectionery at 6.5 ng/kg bw/day (middle bound). For men aged 18-59 years old beer was the main contributor with an intake of 2.60 ng/kg bw/day ("high consumers", middle bound). Tea and grain-based products were identified to be the main contributors for dietary exposure in women aged 18-59 years old. Coffee and wine were identified as a higher contributor of the OTA intake in the population group of women aged 18-59 years old compared to the other population groups.
Imaging evaluation of non-alcoholic fatty liver disease: focused on quantification.
Lee, Dong Ho
2017-12-01
Non-alcoholic fatty liver disease (NAFLD) has been an emerging major health problem, and the most common cause of chronic liver disease in Western countries. Traditionally, liver biopsy has been gold standard method for quantification of hepatic steatosis. However, its invasive nature with potential complication as well as measurement variability are major problem. Thus, various imaging studies have been used for evaluation of hepatic steatosis. Ultrasonography provides fairly good accuracy to detect moderate-to-severe degree hepatic steatosis, but limited accuracy for mild steatosis. Operator-dependency and subjective/qualitative nature of examination are another major drawbacks of ultrasonography. Computed tomography can be considered as an unsuitable imaging modality for evaluation of NAFLD due to potential risk of radiation exposure and limited accuracy in detecting mild steatosis. Both magnetic resonance spectroscopy and magnetic resonance imaging using chemical shift technique provide highly accurate and reproducible diagnostic performance for evaluating NAFLD, and therefore, have been used in many clinical trials as a non-invasive reference of standard method.
Imaging evaluation of non-alcoholic fatty liver disease: focused on quantification
2017-01-01
Non-alcoholic fatty liver disease (NAFLD) has been an emerging major health problem, and the most common cause of chronic liver disease in Western countries. Traditionally, liver biopsy has been gold standard method for quantification of hepatic steatosis. However, its invasive nature with potential complication as well as measurement variability are major problem. Thus, various imaging studies have been used for evaluation of hepatic steatosis. Ultrasonography provides fairly good accuracy to detect moderate-to-severe degree hepatic steatosis, but limited accuracy for mild steatosis. Operator-dependency and subjective/qualitative nature of examination are another major drawbacks of ultrasonography. Computed tomography can be considered as an unsuitable imaging modality for evaluation of NAFLD due to potential risk of radiation exposure and limited accuracy in detecting mild steatosis. Both magnetic resonance spectroscopy and magnetic resonance imaging using chemical shift technique provide highly accurate and reproducible diagnostic performance for evaluating NAFLD, and therefore, have been used in many clinical trials as a non-invasive reference of standard method. PMID:28994271
Deme, Pragney; Azmeera, Tirupathi; Prabhavathi Devi, B L A; Jonnalagadda, Padmaja R; Prasad, R B N; Vijaya Sarathi, U V R
2014-01-01
An improved sample preparation using dispersive solid-phase extraction clean-up was proposed for the trace level determination of 35 multiclass pesticide residues (organochlorine, organophosphorus and synthetic pyrethroids) in edible oils. Quantification of the analytes was carried out by gas chromatography-mass spectrometry in negative chemical ionisation mode (GC-NCI-MS/MS). The limit of detection and limit of quantification of residues were in the range of 0.01-1ng/g and 0.05-2ng/g, respectively. The analytes showed recoveries between 62% and 110%, and the matrix effect was observed to be less than 25% for most of the pesticides. Crude edible oil samples showed endosulfan isomers, p,p'-DDD, α-cypermethrin, chlorpyrifos, and diazinon residues in the range of 0.56-2.14ng/g. However, no pesticide residues in the detection range of the method were observed in refined oils. Copyright © 2013 Elsevier Ltd. All rights reserved.
Zorko, Benjamin; Korun, Matjaž; Mora Canadas, Juan Carlos; Nicoulaud-Gouin, Valerie; Chyly, Pavol; Blixt Buhr, Anna Maria; Lager, Charlotte; Aquilonius, Karin; Krajewski, Pawel
2016-07-01
Several methods for reporting outcomes of gamma-ray spectrometric measurements of environmental samples for dose calculations are presented and discussed. The measurement outcomes can be reported as primary measurement results, primary measurement results modified according to the quantification limit, best estimates obtained by the Bayesian posterior (ISO 11929), best estimates obtained by the probability density distribution resembling shifting, and the procedure recommended by the European Commission (EC). The annual dose is calculated from the arithmetic average using any of these five procedures. It was shown that the primary measurement results modified according to the quantification limit could lead to an underestimation of the annual dose. On the other hand the best estimates lead to an overestimation of the annual dose. The annual doses calculated from the measurement outcomes obtained according to the EC's recommended procedure, which does not cope with the uncertainties, fluctuate between an under- and overestimation, depending on the frequency of the measurement results that are larger than the limit of detection. In the extreme case, when no measurement results above the detection limit occur, the average over primary measurement results modified according to the quantification limit underestimates the average over primary measurement results for about 80%. The average over best estimates calculated according the procedure resembling shifting overestimates the average over primary measurement results for 35%, the average obtained by the Bayesian posterior for 85% and the treatment according to the EC recommendation for 89%. Copyright © 2016 Elsevier Ltd. All rights reserved.
Kim, Sun Ae; Park, Si Hong; Lee, Sang In; Ricke, Steven C
2017-08-01
A novel method was developed for the specific quantification of S. Typhimurium using a most-probable-number (MPN) combined with qPCR and a shortened incubation time (MPN-qPCR-SIT). For S. Typhimurium enumeration, dilutions of samples were transferred into three wells on a microtiter plate and the plate was incubated for 4 h. The S. Typhimurium presence in the wells was identified using a qPCR and populations were determined based on an MPN calculation. The R 2 between the MPN-qPCR-SIT and conventional MPN exhibited a high level of correlation (0.9335-0.9752), suggesting that the MPN-qPCR-SIT offers a reliable alternative method for S. Typhimurium quantification. Although plating and qPCR were limited in their ability to detect low levels of S. Typhimurium (e.g. 0.18 log MPN/ml), these levels could be successfully detected with the MPN-qPCR-SIT. Chicken breast samples inoculated with S. Typhimurium were incubated at 0, 4, and 24 h and incubated samples were subjected to microbiome analysis. Levels of Salmonella and Enterobacteriaceae increased significantly with incubation time. The obvious benefits of the MPN-qPCR-SIT are: 1) a further confirmation step is not required, 2) the detection limit is as low as conventional MPN, but 3) is more rapid, requiring approximately 7 h to simultaneously complete quantification. Copyright © 2017 Elsevier Ltd. All rights reserved.
Bhandari, Pamita; Kumar, Neeraj; Singh, Bikram; Singh, Virendra; Kaur, Inderjeet
2009-08-01
A high performance liquid chromatographic method using a silica-based monolithic column coupled with evaporative light scattering detector (HPLC-ELSD) was developed and validated for simultaneous quantification of bacosides (bacoside A, bacopaside I, bacoside A(3), bacopaside II, bacopaside X, bacopasaponin C) and apigenin in Bacopa monnieri. The chromatographic resolution was achieved on a Chromolith RP-18 (100x4.6 mm) column with acetonitrile/water (30:70) as mobile phase in isocratic elution at a flow rate of 0.7 mL/min. The drift tube temperature of the ELSD was set to 95 degrees C, and the nitrogen flow rate was 2.0 SLM (standard liter per minute). The calibration curves revealed a good linear relationship (r(2) > 0.9988) within the test ranges. The detection limits (S/N = 3) and the quantification limits (S/N = 10) for the compounds were in the range of 0.54-6.06 and 1.61-18.78 microg/mL, respectively. Satisfactory average recovery was observed in the range of 95.8-99.0%. The method showed good reproducibility for the quantification of these compounds in B. monnieri with intra- and inter-day precision of less than 0.69 and 0.67%, respectively. The validated method was successfully applied to quantify analytes in nine accessions of B. monnieri and thus provides a new basis for overall quality assessment of B. monnieri.
Costa, Rosaria; Tedone, Laura; De Grazia, Selenia; Dugo, Paola; Mondello, Luigi
2013-04-03
Multiple headspace-solid phase microextraction (MHS-SPME) followed by gas chromatography/mass spectrometry (GC-MS) and flame ionization detection (GC-FID) was applied to the identification and quantification of volatiles released by the mushroom Agaricus bisporus, also known as champignon. MHS-SPME allows to perform quantitative analysis of volatiles from solid matrices, free of matrix interferences. Samples analyzed were fresh mushrooms (chopped and homogenized) and mushroom-containing food dressings. 1-Octen-3-ol, 3-octanol, 3-octanone, 1-octen-3-one and benzaldehyde were common constituents of the samples analyzed. Method performance has been tested through the evaluation of limit of detection (LoD, range 0.033-0.078 ng), limit of quantification (LoQ, range 0.111-0.259 ng) and analyte recovery (92.3-108.5%). The results obtained showed quantitative differences among the samples, which can be attributed to critical factors, such as the degree of cell damage upon sample preparation, that are here discussed. Considerations on the mushrooms biochemistry and on the basic principles of MHS analysis are also presented. Copyright © 2013 Elsevier B.V. All rights reserved.
Jain, Rajeev; Sinha, Ankita; Khan, Ab Lateef
2016-08-01
A novel polyaniline-graphene oxide nanocomposite (PANI/GO/GCE) sensor has been fabricated for quantification of a calcium channel blocker drug levamlodipine (LAMP). Fabricated sensor has been characterized by electrochemical impedance spectroscopy, square wave and cyclic voltammetry, Raman spectroscopy and Fourier transform infrared (FTIR) spectroscopy. The developed PANI/GO/GCE sensor has excellent analytical performance towards electrocatalytic oxidation as compared to PANI/GCE, GO/GCE and bare GCE. Under optimized experimental conditions, the fabricated sensor exhibits a linear response for LAMP for its oxidation over a concentration range from 1.25μgmL(-1) to 13.25μgmL(-1) with correlation coefficient of 0.9950 (r(2)), detection limit of 1.07ngmL(-1) and quantification limit of 3.57ngmL(-1). The sensor shows an excellent performance for detecting LAMP with reproducibility of 2.78% relative standard deviation (RSD). The proposed method has been successfully applied for LAMP determination in pharmaceutical formulation with a recovery from 99.88% to 101.75%. Copyright © 2015 Elsevier B.V. All rights reserved.
Bostijn, N; Hellings, M; Van Der Veen, M; Vervaet, C; De Beer, T
2018-07-12
UltraViolet (UV) spectroscopy was evaluated as an innovative Process Analytical Technology (PAT) - tool for the in-line and real-time quantitative determination of low-dosed active pharmaceutical ingredients (APIs) in a semi-solid (gel) and a liquid (suspension) pharmaceutical formulation during their batch production process. The performance of this new PAT-tool (i.e., UV spectroscopy) was compared with an already more established PAT-method based on Raman spectroscopy. In-line UV measurements were carried out with an immersion probe while for the Raman measurements a non-contact PhAT probe was used. For both studied formulations, an in-line API quantification model was developed and validated per spectroscopic technique. The known API concentrations (Y) were correlated with the corresponding in-line collected preprocessed spectra (X) through a Partial Least Squares (PLS) regression. Each developed quantification method was validated by calculating the accuracy profile on the basis of the validation experiments. Furthermore, the measurement uncertainty was determined based on the data generated for the determination of the accuracy profiles. From the accuracy profile of the UV- and Raman-based quantification method for the gel, it was concluded that at the target API concentration of 2% (w/w), 95 out of 100 future routine measurements given by the Raman method will not deviate more than 10% (relative error) from the true API concentration, whereas for the UV method the acceptance limits of 10% were exceeded. For the liquid formulation, the Raman method was not able to quantify the API in the low-dosed suspension (0.09% (w/w) API). In contrast, the in-line UV method was able to adequately quantify the API in the suspension. This study demonstrated that UV spectroscopy can be adopted as a novel in-line PAT-technique for low-dose quantification purposes in pharmaceutical processes. Important is that none of the two spectroscopic techniques was superior to the other for both formulations: the Raman method was more accurate in quantifying the API in the gel (2% (w/w) API), while the UV method performed better for API quantification in the suspension (0.09% (w/w) API). Copyright © 2018 Elsevier B.V. All rights reserved.
Stravs, Michael A; Mechelke, Jonas; Ferguson, P Lee; Singer, Heinz; Hollender, Juliane
2016-03-01
Online solid-phase extraction was combined with nano-liquid chromatography coupled to high-resolution mass spectrometry (HRMS) for the analysis of micropollutants in environmental samples from small volumes. The method was validated in surface water, Microcystis aeruginosa cell lysate, and spent Microcystis growth medium. For 41 analytes, quantification limits of 0.1-28 ng/L (surface water) and 0.1-32 ng/L (growth medium) were obtained from only 88 μL of sample. In cell lysate, quantification limits ranged from 0.1-143 ng/L or 0.33-476 ng/g dry weight from a sample of 88 μL, or 26 μg dry weight, respectively. The method matches the sensitivity of established online and offline solid-phase extraction-liquid chromatography-mass spectrometry methods but requires only a fraction of the sample used by those techniques, and is among the first applications of nano-LC-MS for environmental analysis. The method was applied to the determination of bioconcentration in Microcystis aeruginosa in a laboratory experiment, and the benefit of coupling to HRMS was demonstrated in a transformation product screening.
Chi, Shuyao; Wu, Dike; Sun, Jinhong; Ye, Ruhan; Wang, Xiaoyan
2014-05-01
A headspace gas chromatography (HS-GC) method was developed for the simultaneous determination of seven residual solvents (petroleum ether (60-90 degrees C), acetone, ethyl acetate, methanol, methylene chloride, ethanol and butyl acetate) in bovis calculus artifactus. The DB-WAX capillary column and flame ionization detector (FID) were used for the separation and detection of the residual solvents, and the internal standard method was used for the quantification. The chromatographic conditions, such as equilibrium temperature and equilibrium time, were optimized. Under the optimized conditions, all of the seven residual solvents showed good linear relationships with good correlation coefficients (not less than 0.999 3) in the prescribed concentration range. At three spiked levels, the recoveries for the seven residual solvents were 94.7%-105.2% with the relative standard deviations (RSDs) less than 3.5%. The limits of detection (LODs) of the method were 0.43-5.23 mg/L, and the limits of quantification (LOQs) were 1.25-16.67 mg/L. The method is simple, rapid, sensitive and accurate, and is suitable for the simultaneous determination of the seven residual solvents in bovis calculus artifactus.
Simultaneous determination of ezetimibe and simvastatin in pharmaceutical preparations by MEKC.
Yardimci, Ceren; Ozaltin, Nuran
2010-02-01
A micellar electrokinetic capillary chromatography method was developed and validated for the simultaneous determination of ezetimibe and simvastatin in pharmaceutical preparations. The influence of buffer concentration, buffer pH, sodium dodecyl sulphate (SDS) concentration, organic modifier, capillary temperature, applied voltage, and injection time was investigated, and the method validation studies were performed. The optimum separation for these analytes was achieved in less than 10 min at 30 degrees C with a fused-silica capillary column (56 cm x 50 microm i.d.) and a 25mM borate buffer at pH 9.0 containing 25mM SDS and 10% (v/v) acetonitrile. The samples were injected hydrodynamically for 3 s at 50 mbar, and the applied voltage was +30.0 kV. Detection wavelength was set at 238 nm. Diflunisal was used as internal standard. The method was suitably validated with respect to stability, specificity, linearity, limits of detection and quantification, accuracy, precision, and robustness. The limits of detection and quantification were 1.0 and 2.0 microg/mL for both ezetimibe and simvastatin, respectively. The method developed was successfully applied to the simultaneous determination of ezetimibe and simvastatin in pharmaceutical preparations.
Determination of etoxazole residues in fruits and vegetables by SPE clean-up and HPLC-DAD.
Malhat, Farag; Badawy, Hany; Barakat, Dalia; Saber, Ayman
2013-01-01
A method for determination of etoxazole residues in apples, strawberries and green beans was developed and validated. The analyte was extracted with acetonitrile from foodstuff and a charcoal-celite cartridge was used for clean-up of raw extracts. Reversed phase high performance liquid chromatography with photodiode array detector (HPLC-DAD) was used for the determination and quantification of etoxazole residues in the studied samples. The calibration graphs of etoxazole in a solvent or three blank matrixes were linear within the tested intervals 0.01-2 mg L(-1), with correlation coefficient of determination >0.999. The combined solid phase extraction (SPE) clean-up and the chromatographic method steps were sensitive and reliable for simultaneous determination of etoxazole residues in the studied samples. The average recoveries of etoxazole in the tested foodstuffs were between 93.4 to 102% at spiking levels of 0.01, 0.10, and 0.50 mg kg(-1), with relative standard deviations ranging from 2.8 to 4.7%, in agreement with directives for method validation in residue analyses. The limit of detection (LOD) of the HPLC-DAD system was 100 pg. The limit of quantification of the entire method was 0.01 mg kg(-1).
Methods and techniques for measuring gas emissions from agricultural and animal feeding operations.
Hu, Enzhu; Babcock, Esther L; Bialkowski, Stephen E; Jones, Scott B; Tuller, Markus
2014-01-01
Emissions of gases from agricultural and animal feeding operations contribute to climate change, produce odors, degrade sensitive ecosystems, and pose a threat to public health. The complexity of processes and environmental variables affecting these emissions complicate accurate and reliable quantification of gas fluxes and production rates. Although a plethora of measurement technologies exist, each method has its limitations that exacerbate accurate quantification of gas fluxes. Despite a growing interest in gas emission measurements, only a few available technologies include real-time, continuous monitoring capabilities. Commonly applied state-of-the-art measurement frameworks and technologies were critically examined and discussed, and recommendations for future research to address real-time monitoring requirements for forthcoming regulation and management needs are provided.
Bozzolino, Cristina; Leporati, Marta; Gani, Federica; Ferrero, Cinzia; Vincenti, Marco
2018-02-20
A fast analytical method for the simultaneous detection of 24 β 2 -agonists in human urine was developed and validated. The method covers the therapeutic drugs most commonly administered, but also potentially abused β 2 -agonists. The procedure is based on enzymatic deconjugation with β-glucuronidase followed by SPE clean up using mixed-phase cartridges with both ion-exchange and lipophilic properties. Instrumental analysis conducted by UHPLC-MS/MS allowed high peak resolution and rapid chromatographic separation, with reduced time and costs. The method was fully validated according ISO 17025:2005 principles. The following parameters were determined for each analyte: specificity, selectivity, linearity, limit of detection, limit of quantification, precision, accuracy, matrix effect, recovery and carry-over. The method was tested on real samples obtained from patients subjected to clinical treatment under chronic or acute therapy with either formoterol, indacaterol, salbutamol, or salmeterol. The drugs were administered using pressurized metered dose inhalers. All β 2 -agonists administered to the patients were detected in the real samples. The method proved adequate to accurately measure the concentration of these analytes in the real samples. The observed analytical data are discussed with reference to the administered dose and the duration of the therapy. Copyright © 2017 Elsevier B.V. All rights reserved.
Abdallah, H; Arnaudguilhem, C; Jaber, F; Lobinski, R
2014-08-15
A new high performance liquid chromatography-high resolution mass spectrometry (HPLC-HRMS) method was developed for a simultaneous multi-residue analysis of 22 sulfonamides (SAs) and their metabolites in edible animal (pig, beef, sheep and chicken) tissues. Sample preparation was optimized on the basis of the "QuEChERS" protocol. The analytes were identified using their LC retention times and accurate mass; the identification was further confirmed by multi-stage high mass accuracy (<5ppm) mass spectrometry. The performance of the method was evaluated according to the EU guidelines for the validation of screening methods for the analysis of veterinary drugs residues. Acceptable values were obtained for: linearity (R(2)<0.99), limit of detection (LOD, 3-26μg/kg), limit of quantification (LOQ, 11-88μg/kg), accuracy (recovery 88-112%), intra- and inter-day precision 1-14 and 1-17%, respectively, decision limit (CCα) and detection capability (CCβ) around the maximum residue limits (MRL) of SAs (100μg/kg). The method was validated by analysis of a reference material FAPAS-02188 "Pig kidney" with ǀ Z-scoreǀ<0.63. The method was applied to various matrices (kidney, liver, muscle) originated from pig, beef, sheep, and chicken) allowing the simultaneous quantification of target sulfonamides at concentration levels above the MRL/2 and the identification of untargeted compounds such as N(4)-acetyl metabolites using multi-stage high mass accuracy mass spectrometry. Copyright © 2014 Elsevier B.V. All rights reserved.
Structural neuroimaging in neuropsychology: History and contemporary applications.
Bigler, Erin D
2017-11-01
Neuropsychology's origins began long before there were any in vivo methods to image the brain. That changed with the advent of computed tomography in the 1970s and magnetic resonance imaging in the early 1980s. Now computed tomography and magnetic resonance imaging are routinely a part of neuropsychological investigations with an increasing number of sophisticated methods for image analysis. This review examines the history of neuroimaging utilization in neuropsychological investigations, highlighting the basic methods that go into image quantification and the various metrics that can be derived. Neuroimaging methods and limitations for identify what constitutes a lesion are discussed. Likewise, the influence of various demographic and developmental factors that influence quantification of brain structure are reviewed. Neuroimaging is an integral part of 21st Century neuropsychology. The importance of neuroimaging to advancing neuropsychology is emphasized. (PsycINFO Database Record (c) 2018 APA, all rights reserved).
Mitrowska, Kamila; Vincent, Ursula; von Holst, Christoph
2012-04-13
The manuscript presents the development of a new reverse phase high performance liquid chromatography (RP-HPLC) photo diode array detection method allowing the separation and quantification of 15 carotenoids (adonirubin, adonixanthin, astaxanthin, astaxanthin dimethyl disuccinate, asteroidenone, beta-apo-8'-carotenal, beta-apo-8'-carotenoic acid ethyl ester, beta-carotene, canthaxanthin, capsanthin, citranaxanthin, echinenone, lutein, lycopene, and zeaxanthin), 10 of which are feed additives authorised within the European Union. The developed method allows for the reliable determination of the total carotenoid content in one run using the corresponding E-isomer as calibration standard while taking into account the E/Z-isomers composition. This is a key criterion for the application of the method, since for most of the analytes included in this study analytical standards are only available for the E-isomers. This goal was achieved by applying the isosbestic concept, in order to identify specific wavelengths, at which the absorption coefficients are identical for all stereoisomers concerned. The second target referred to the optimisation of the LC conditions. By means of an experimental design, an optimised RP-HPLC method was developed allowing for a sufficient chromatographic separation of all carotenoids. The selected method uses a Suplex pKb-100 HPLC column and applying a gradient with a mixture of acetonitrile, tert-butyl-methyl ether and water as mobile phases. The limits of detection and limits of quantification ranged from 0.06 mg L(-1) to 0.14 mg L(-1) and from 0.20 mg L(-1) to 0.48 mg L(-1), respectively. Copyright © 2012 Elsevier B.V. All rights reserved.
Sensitive and selective quantification of free and total malondialdehyde in plasma using UHPLC-HRMS.
Mendonça, Rute; Gning, Ophélie; Di Cesaré, Claudia; Lachat, Laurence; Bennett, Nigel C; Helfenstein, Fabrice; Glauser, Gaétan
2017-09-01
Quantification of malondialdehyde (MDA) as a marker of lipid peroxidation is relevant for many research fields. We describe a new sensitive and selective method to measure free and total plasmatic MDA using derivatization with 2,4-dinitrophenylhydrazine (DNPH) and ultra-HPLC-high-resolution MS. Free and total MDA were extracted from minute sample amounts (10 μl) using acidic precipitation and alkaline hydrolysis followed by acidic precipitation, respectively. Derivatization was completed within 10 min at room temperature, and the excess DNPH discarded by liquid-liquid extraction. Quantification was achieved by internal standardization using dideuterated MDA as internal standard. The method's lowest limit of quantification was 100 nM and linearity spanned greater than three orders of magnitude. Intra- and inter-day precisions for total MDA were 2.9% and 3.0%, respectively, and those for free MDA were 12.8% and 24.9%, respectively. Accuracy was 101% and 107% at low and high concentrations, respectively. In human plasma, free MDA levels were 120 nM (SD 36.26) and total MDA levels were 6.7 μM (SD 0.46). In addition, we show the applicability of this method to measure MDA plasma levels from a variety of animal species, making it invaluable to scientists in various fields. Copyright © 2017 by the American Society for Biochemistry and Molecular Biology, Inc.
Quantification of protein concentration using UV absorbance and Coomassie dyes.
Noble, James E
2014-01-01
The measurement of a solubilized protein concentration in solution is an important assay in biochemistry research and development labs for applications ranging from enzymatic studies to providing data for biopharmaceutical lot release. Spectrophotometric protein quantification assays are methods that use UV and visible spectroscopy to rapidly determine the concentration of protein, relative to a standard, or using an assigned extinction coefficient. Where multiple samples need measurement, and/or the sample volume and concentration is limited, preparations of the Coomassie dye commonly known as the Bradford assay can be used. © 2014 Elsevier Inc. All rights reserved.
Gaudin, Zachary; Cerveau, Delphine; Marnet, Nathalie; Bouchereau, Alain; Delavault, Philippe; Simier, Philippe; Pouvreau, Jean-Bernard
2014-01-21
An AccQ•Tag ultra performance liquid chromatography-photodiode array-electrospray ionization-mass spectrometry (AccQ•Tag-UPLC-PDA-ESI-MS) method is presented here for the fast, robust, and sensitive quantification of (15)N isotopologue enrichment of amino acids in biological samples, as for example in the special biotic interaction between the cultivated specie Brassica napus (rapeseed) and the parasitic weed Phelipanche ramosa (broomrape). This method was developed and validated using amino acid standard solutions containing (15)N amino acid isotopologues and/or biological unlabeled extracts. Apparatus optimization, limits of detection and quantification, quantification reproducibility, and calculation method of (15)N isotopologue enrichment are presented. Using this method, we could demonstrate that young parasite tubercles assimilate inorganic nitrogen as (15)N-ammonium when supplied directly through batch incubation but not when supplied by translocation from host root phloem, contrary to (15)N2-glutamine. (15)N2-glutamine mobility from host roots to parasite tubercles followed by its low metabolism in tubercles suggests that the host-derived glutamine acts as an important nitrogen containing storage compound in the young tubercle of Phelipanche ramosa.
Izanloo, Maryam; Esrafili, Ali; Behbahani, Mohammad; Ghambarian, Mahnaz; Reza Sobhi, Hamid
2018-02-01
Herein, a new dispersive solid-phase extraction method using a nano magnetic titanium dioxide graphene-based sorbent in conjunction with high-performance liquid chromatography and ultraviolet detection was successfully developed. The method was proved to be simple, sensitive, and highly efficient for the trace quantification of sulfacetamide, sulfathiazole, sulfamethoxazole, and sulfadiazine in relatively large volume of aqueous media. Initially, the nano magnetic titanium dioxide graphene-based sorbent was successfully synthesized and subsequently characterized by scanning electron microscopy and X-ray diffraction. Then, the sorbent was used for the sorption and extraction of the selected sulfonamides mainly through π-π stacking hydrophobic interactions. Under the established conditions, the calibration curves were linear over the concentration range of 1-200 μg/L. The limit of quantification (precision of 20%, and accuracy of 80-120%) for the detection of each sulfonamide by the proposed method was 1.0 μg/L. To test the extraction efficiency, the method was applied to various fortified real water samples. The average relative recoveries obtained from the fortified samples varied between 90 and 108% with the relative standard deviations of 5.3-10.7%. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Mull, Bonnie J.; Narayanan, Jothikumar; Hill, Vincent R.
2013-01-01
Primary amebic meningoencephalitis (PAM) is a rare and typically fatal infection caused by the thermophilic free-living ameba, Naegleria fowleri. In 2010, the first confirmed case of PAM acquired in Minnesota highlighted the need for improved detection and quantification methods in order to study the changing ecology of N. fowleri and to evaluate potential risk factors for increased exposure. An immunomagnetic separation (IMS) procedure and real-time PCR TaqMan assay were developed to recover and quantify N. fowleri in water and sediment samples. When one liter of lake water was seeded with N. fowleri strain CDC:V212, the method had an average recovery of 46% and detection limit of 14 amebas per liter of water. The method was then applied to sediment and water samples with unknown N. fowleri concentrations, resulting in positive direct detections by real-time PCR in 3 out of 16 samples and confirmation of N. fowleri culture in 6 of 16 samples. This study has resulted in a new method for detection and quantification of N. fowleri in water and sediment that should be a useful tool to facilitate studies of the physical, chemical, and biological factors associated with the presence and dynamics of N. fowleri in environmental systems. PMID:24228172
Grandin, Flore; Picard-Hagen, Nicole; Gayrard, Véronique; Puel, Sylvie; Viguié, Catherine; Toutain, Pierre-Louis; Debrauwer, Laurent; Lacroix, Marlène Z
2017-12-01
Regulatory measures and public concerns regarding bisphenol A (BPA) have led to its replacement by structural analogues, such as Bisphenol S (BPS), in consumer products. At present, no toxicokinetic investigations have been conducted to assess the factors determining human internal exposure to BPS for subsequent risk assessment. Toxicokinetic studies require reliable analytical methods to measure the plasma concentrations of BPS and its main conjugated metabolite, BPS-glucuronide (BPS-G). An efficient on-line SPE-UPLC-MS/MS method for the simultaneous quantification of BPS and BPS-G in ovine plasma was therefore developed and validated in accordance with the European Medicines Agency guidelines for bioanalytical method validation. This method has a limit of quantification of 3ngmL -1 for BPS and 10ngmL -1 for BPS-G, an analytical capacity of 200 samples per day, and is particularly well suited to toxicokinetic studies. Use of this method in toxicokinetic studies in sheep showed that BPS, like BPA, is efficiently metabolized into its glucuronide form. However, the clearances and distributions of BPS and BPS-G were lower than those of the corresponding unconjugated and glucuroconjugated forms of BPA. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Rodigast, M.; Mutzel, A.; Iinuma, Y.; Haferkorn, S.; Herrmann, H.
2015-01-01
Carbonyl compounds are ubiquitous in the atmosphere and either emitted primarily from anthropogenic and biogenic sources or they are produced secondarily from the oxidation of volatile organic compounds (VOC). Despite a number of studies about the quantification of carbonyl compounds a comprehensive description of optimised methods is scarce for the quantification of atmospherically relevant carbonyl compounds. Thus a method was systematically characterised and improved to quantify carbonyl compounds. Quantification with the present method can be carried out for each carbonyl compound sampled in the aqueous phase regardless of their source. The method optimisation was conducted for seven atmospherically relevant carbonyl compounds including acrolein, benzaldehyde, glyoxal, methyl glyoxal, methacrolein, methyl vinyl ketone and 2,3-butanedione. O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA) was used as derivatisation reagent and the formed oximes were detected by gas chromatography/mass spectrometry (GC/MS). The main advantage of the improved method presented in this study is the low detection limit in the range of 0.01 and 0.17 μmol L-1 depending on carbonyl compounds. Furthermore best results were found for extraction with dichloromethane for 30 min followed by derivatisation with PFBHA for 24 h with 0.43 mg mL-1 PFBHA at a pH value of 3. The optimised method was evaluated in the present study by the OH radical initiated oxidation of 3-methylbutanone in the aqueous phase. Methyl glyoxal and 2,3-butanedione were found to be oxidation products in the samples with a yield of 2% for methyl glyoxal and 14% for 2,3-butanedione.
Quantification of Liver Iron with MRI: State of the Art and Remaining Challenges
Hernando, Diego; Levin, Yakir S; Sirlin, Claude B; Reeder, Scott B
2015-01-01
Liver iron overload is the histological hallmark of hereditary hemochromatosis and transfusional hemosiderosis, and can also occur in chronic hepatopathies. Iron overload can result in liver damage, with the eventual development of cirrhosis, liver failure and hepatocellular carcinoma. Assessment of liver iron levels is necessary for detection and quantitative staging of iron overload, and monitoring of iron-reducing treatments. This article discusses the need for non-invasive assessment of liver iron, and reviews qualitative and quantitative methods with a particular emphasis on MRI. Specific MRI methods for liver iron quantification include signal intensity ratio as well as R2 and R2* relaxometry techniques. Methods that are in clinical use, as well as their limitations, are described. Remaining challenges, unsolved problems, and emerging techniques to provide improved characterization of liver iron deposition are discussed. PMID:24585403
Akdoğan, Abdullah; Buttinger, Gerhard; Wenzl, Thomas
2016-01-01
An analytical method is reported for the determination of four polycyclic aromatic hydrocarbons (benzo[a]pyrene (BaP), benz[a]anthracene (BaA), benzo[b]fluoranthene (BbF) and chrysene (CHR)) in edible oils (sesame, maize, sunflower and olive oil) by high-performance liquid chromatography. Sample preparation is based on three steps including saponification, liquid-liquid partitioning and, finally, clean-up by solid phase extraction on 2 g of silica. Guidance on single-laboratory validation of the proposed analysis method was taken from the second edition of the Eurachem guide on method validation. The lower level of the working range of the method was determined by the limits of quantification of the individual analytes, and the upper level was equal to 5.0 µg kg(-1). The limits of detection and quantification of the four PAHs ranged from 0.06 to 0.12 µg kg(-1) and from 0.13 to 0.24 µg kg(-1). Recoveries of more than 84.8% were achieved for all four PAHs at two concentration levels (2.5 and 5.0 µg kg(-1)), and expanded relative measurement uncertainties were below 20%. The performance of the validated method was in all aspects compliant with provisions set in European Union legislation for the performance of analytical methods employed in the official control of food. The applicability of the method to routine samples was evaluated based on a limited number of commercial edible oil samples.
Rajendra Reddy, Gangireddy; Ravindra Reddy, Papammagari; Siva Jyothi, Polisetty
2015-01-01
A novel, simple, precise, and stability-indicating stereoselective method was developed and validated for the accurate quantification of the enantiomer in the drug substance and pharmaceutical dosage forms of Rosuvastatin Calcium. The method is capable of quantifying the enantiomer in the presence of other related substances. The chromatographic separation was achieved with an immobilized cellulose stationary phase (Chiralpak IB) 250 mm x 4.6 mm x 5.0 μm particle size column with a mobile phase containing a mixture of n-hexane, dichloromethane, 2-propanol, and trifluoroacetic acid in the ratio 82:10:8:0.2 (v/v/v/v). The eluted compounds were monitored at 243 nm and the run time was 18 min. Multivariate analysis and statistical tools were used to develop this highly robust method in a short span of time. The stability-indicating power of the method was established by subjecting Rosuvastatin Calcium to the stress conditions (forced degradation) of acid, base, oxidative, thermal, humidity, and photolytic degradation. Major degradation products were identified and found to be well-resolved from the enantiomer peak, proving the stability-indicating power of the method. The developed method was validated as per International Conference on Harmonization (ICH) guidelines with respect to specificity, limit of detection and limit of quantification, precision, linearity, accuracy, and robustness. The method exhibited consistent, high-quality recoveries (100 ± 10%) with a high precision for the enantiomer. Linear regression analysis revealed an excellent correlation between the peak responses and concentrations (r2 value of 0.9977) for the enantiomer. The method is sensitive enough to quantify the enantiomer above 0.04% and detect the enantiomer above 0.015% in Rosuvastatin Calcium. The stability tests were also performed on the drug substances as per ICH norms. PMID:26839815
Gavra, Paul; Nguyen, Anne Q-N; Theoret, Yves; Litalien, Catherine; Denault, André Y; Varin, France
2014-10-01
Milrinone administered through inhalation is an emerging method aimed at specifically reducing pulmonary hypertension without affecting systemic pressures. Its administration has been shown to be useful both in patients undergoing cardiac surgery and for persistent pulmonary hypertension of the newborn. These populations are prone to receive many concomitant medications and/or blood sampling may require a low volume quantification method. To address these issues in view of pharmacokinetic studies, this article aims to develop and validate a specific and sensitive analytical assay using high performance liquid chromatography (HPLC) and tandem mass spectrometry (MS/MS) detection for the quantification of milrinone plasma concentrations after inhalation in patients undergoing cardiac surgery. Plasma samples (50 μL) were extracted using ethyl acetate. Milrinone was separated on a C18 analytical column at 50°C. The mobile phase consisted of methanol and 10 mM ammonium acetate (45:55 vol/vol). The electrospray was operated in the negative ionization mode and monitored the following mass transitions: m/z 212.1 → 140.0 at 36 eV for milrinone and m/z 252.1 → 156.1 at 32 eV for olprinone. Calibration curves followed a quadratic regression in the concentration range of 0.3125-640 ng/mL. The lower limit of quantification is 0.3125 ng/mL and is based on a low plasma volume of 50 μL. Mean drug recovery and accuracy were ≥72.3% and 96.0%, respectively. Intraday and interday precision coefficient of variation (%) was ≤7.4% and ≤11.5%, respectively. The specificity allowed milrinone quantification in the multidrug administration conditions of cardiopulmonary bypass. This validated micromethod proved to be highly sensitive and specific while using a low volume of plasma. Its low volume and its lower limit of quantification indicate that this approach is suitable for further characterization of milrinone pharmacokinetics in both adults (inhalation) and neonates.
Tao, Huang; Yun-Hai, Guo; He-Xiang, Liu; Yi, Zhang
2018-04-19
To establish a method for the quantitative determination of serotonin and dopamine in the nervous system of Biomphalaria glabrata by using ultra high performance liquid chromatography-tandem quadrupole mass spectrometry (UPLC MS/MS) . The B. glabrata nervous system was broken in the pure methanol solution after obtaining it by dissecting with microscope. Then, the supernatant containing the target substance after twice high speed centrifugation was got. The extraction was separated on an ACQUITY UPLC BEH Amide column with Waters TQ-XS series mass spectrometry detector, with ESI source and positive electrospray ionization mode when the machine testing. The detection limit of serotonin was 0.03 ng/ml and the limit of quantification was 0.1 ng/ml. The detection limit of dopamine was 0.05 ng/ml and the limit of quantification was 0.15 ng/ml. The recoveries of serotonin ranged from 90.68% to 94.72% over the range of 1 to 40 ng/ml. The recoveries of dopamine ranged from 91.68% to 96.12% over the range of 1.0 ng/ml to 40 ng/ml. The established UPLC MS/MS method is simple, stable and reproducible. It can be used for the quantitative analysis of serotonin and dopamine in the nervous system of B. glabrata snails.
NASA Astrophysics Data System (ADS)
Rodigast, M.; Mutzel, A.; Iinuma, Y.; Haferkorn, S.; Herrmann, H.
2015-06-01
Carbonyl compounds are ubiquitous in the atmosphere and either emitted primarily from anthropogenic and biogenic sources or they are produced secondarily from the oxidation of volatile organic compounds. Despite a number of studies about the quantification of carbonyl compounds a comprehensive description of optimised methods is scarce for the quantification of atmospherically relevant carbonyl compounds. The method optimisation was conducted for seven atmospherically relevant carbonyl compounds including acrolein, benzaldehyde, glyoxal, methyl glyoxal, methacrolein, methyl vinyl ketone and 2,3-butanedione. O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA) was used as derivatisation reagent and the formed oximes were detected by gas chromatography/mass spectrometry (GC/MS). With the present method quantification can be carried out for each carbonyl compound originating from fog, cloud and rain or sampled from the gas- and particle phase in water. Detection limits between 0.01 and 0.17 μmol L-1 were found, depending on carbonyl compounds. Furthermore, best results were found for the derivatisation with a PFBHA concentration of 0.43 mg mL-1 for 24 h followed by a subsequent extraction with dichloromethane for 30 min at pH = 1. The optimised method was evaluated in the present study by the OH radical initiated oxidation of 3-methylbutanone in the aqueous phase. Methyl glyoxal and 2,3-butanedione were found to be oxidation products in the samples with a yield of 2% for methyl glyoxal and 14% for 2,3-butanedione after a reaction time of 5 h.
2011-01-01
Background Botrytis cinerea is a phytopathogenic fungus responsible for the disease known as gray mold, which causes substantial losses of fruits at postharvest. This fungus is present often as latent infection and an apparently healthy fruit can deteriorate suddenly due to the development of this infection. For this reason, rapid and sensitive methods are necessary for its detection and quantification. This article describes the development of an indirect competitive enzyme-linked immunosorbent assay (ELISA) for quantification of B. cinerea in apple (Red Delicious), table grape (pink Moscatel), and pear (William's) tissues. Results The method was based in the competition for the binding site of monoclonal antibodies between B. cinerea antigens present in fruit tissues and B. cinerea purified antigens immobilized by a crosslinking agent onto the surface of the microtiter plates. The method was validated considering parameters such as selectivity, linearity, precision, accuracy and sensibility. The calculated detection limit was 0.97 μg mL-1 B. cinerea antigens. The immobilized antigen was perfectly stable for at least 4 months assuring the reproducibility of the assay. The fungus was detected and quantified in any of the fruits tested when the rot was not visible yet. Results were compared with a DNA quantification method and these studies showed good correlation. Conclusions The developed method allowed detects the presence of B. cinerea in asymptomatic fruits and provides the advantages of low cost, easy operation, and short analysis time determination for its possible application in the phytosanitary programs of the fruit industry worldwide. PMID:21970317
Nakov, Natalija; Bogdanovska, Liljana; Acevska, Jelena; Tonic-Ribarska, Jasmina; Petkovska, Rumenka; Dimitrovska, Aneta; Kasabova, Lilia; Svinarov, Dobrin
2016-11-01
In this research, as a part of the development of fast and reliable HPLC-MS/MS method for quantification of ibuprofen (IBP) enantiomers in human plasma, the possibility of IBP acylglucoronide (IBP-Glu) back-conversion was assessed. This involved investigation of in source and in vitro back-conversion. The separation of IBP enantiomers, its metabolite and rac-IBP-d3 (internal standard), was achieved within 6 min using Chiracel OJ-RH chromatographic column (150 × 2.1 mm, 5 μm). The followed selected reaction monitoring transitions for IBP-Glu (m/z 381.4 → 205.4, m/z 381.4 → 161.4 and m/z 205.4 → 161.4) implied that under the optimized electrospray ionization parameters, in source back-conversion of IBP-Glu was insignificant. The results obtained after liquid-liquid extraction of plasma samples spiked with IBP-Glu revealed that the amount of IBP enantiomers generated by IBP-Glu back-conversion was far <20% of lower limit of quantification sample. These results indicate that the presence of IBP-Glu in real samples will not affect the quantification of the IBP enantiomers; thereby reliability of the method was improved. Additional advantage of the method is the short analysis time making it suitable for the large number of samples. The method was fully validated according to the EMA guideline and was shown to meet all requirements to be applied in a pharmacokinetic study. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Identification and quantification of cardiac glycosides in blood and urine samples by HPLC/MS/MS.
Guan, F; Ishii, A; Seno, H; Watanabe-Suzuki, K; Kumazawa, T; Suzuki, O
1999-09-15
Cardiac glycosides (CG) are of forensic importance because of their toxicity and the fact that very limited methods are available for identification of CG in biological samples. In this study, we have developed an identification and quantification method for digoxin, digitoxin, deslanoside, digoxigenin, and digitoxigenin by high-performance liquid chromatography tandem mass spectrometry (HPLC/MS/MS). CG formed abundant [M + NH4]+ ions and much less abundant [M + H]+ ions as observed with electrospray ionization (ESI) source and ammonium formate buffer. Under mild conditions for collision-induced dissociation (CID), each [M + NH4]+ ion fragmented to produce a dominant daughter ion, which was essential to the sensitive method of selected reaction monitoring (SRM) quantification of CG achieved in this study. SRM was compared with selected ion monitoring (SIM) regarding the effects of sample matrixes on the methodology. SRM produced lower detection limits with biological samples than SIM, while both methods produced equal detection limits with CG standards. On the basis of the HPLC/MS/MS results for CG, we have proposed some generalized points for conducting sensitive SRM measurements, in view of the property of analytes as well as instrumental conditions such as the type of HPLC/MS interface and CID parameters. Analytes of which the molecular ion can produce one abundant daughter ion with high yield under CID conditions may be sensitively measured by SRM. ESI is the most soft ionization source developed so far and can afford formation of the fragile molecular ions that are necessary for sensitive SRM detection. Mild CID conditions such as low collision energy and low pressure of collision gas favor production of an abundant daughter ion that is essential to sensitive SRM detection. This knowledge may provide some guidelines for conducting sensitive SRM measurements of very low concentrations of drugs or toxicants in biological samples.
Electrochemical Nanoparticle Sizing Via Nano-Impacts: How Large a Nanoparticle Can be Measured?
Bartlett, Thomas R; Sokolov, Stanislav V; Compton, Richard G
2015-01-01
The field of nanoparticle (NP) sizing encompasses a wide array of techniques, with electron microscopy and dynamic light scattering (DLS) having become the established methods for NP quantification; however, these techniques are not always applicable. A new and rapidly developing method that addresses the limitations of these techniques is the electrochemical detection of NPs in solution. The ‘nano-impacts’ technique is an excellent and qualitative in situ method for nanoparticle characterization. Two complementary studies on silver and silver bromide nanoparticles (NPs) were used to assess the large radius limit of the nano-impact method for NP sizing. Noting that by definition a NP cannot be larger than 100 nm in diameter, we have shown that the method quantitatively sizes at the largest limit, the lower limit having been previously reported as ∼6 nm.1 PMID:26491639
Fridman, Yulia; Holland, Neta; Elbaum, Rivka; Savaldi-Goldstein, Sigal
2016-05-10
Plant cells are surrounded by a cell wall, the composition of which determines their final size and shape. The cell wall is composed of a complex matrix containing polysaccharides that include cellulose microfibrils that form both crystalline structures and cellulose chains of amorphous organization. The orientation of the cellulose fibers and their concentrations dictate the mechanical properties of the cell. Several methods are used to determine the levels of crystalline cellulose, each bringing both advantages and limitations. Some can distinguish the proportion of crystalline regions within the total cellulose. However, they are limited to whole-organ analyses that are deficient in spatiotemporal information. Others relying on live imaging, are limited by the use of imprecise dyes. Here, we report a sensitive polarized light-based system for specific quantification of relative light retardance, representing crystalline cellulose accumulation in cross sections of Arabidopsis thaliana roots. In this method, the cellular resolution and anatomical data are maintained, enabling direct comparisons between the different tissues composing the growing root. This approach opens a new analytical dimension, shedding light on the link between cell wall composition, cellular behavior and whole-organ growth.
Fridman, Yulia; Holland, Neta; Elbaum, Rivka; Savaldi-Goldstein, Sigal
2016-01-01
Plant cells are surrounded by a cell wall, the composition of which determines their final size and shape. The cell wall is composed of a complex matrix containing polysaccharides that include cellulose microfibrils that form both crystalline structures and cellulose chains of amorphous organization. The orientation of the cellulose fibers and their concentrations dictate the mechanical properties of the cell. Several methods are used to determine the levels of crystalline cellulose, each bringing both advantages and limitations. Some can distinguish the proportion of crystalline regions within the total cellulose. However, they are limited to whole-organ analyses that are deficient in spatiotemporal information. Others relying on live imaging, are limited by the use of imprecise dyes. Here, we report a sensitive polarized light-based system for specific quantification of relative light retardance, representing crystalline cellulose accumulation in cross sections of Arabidopsis thaliana roots. In this method, the cellular resolution and anatomical data are maintained, enabling direct comparisons between the different tissues composing the growing root. This approach opens a new analytical dimension, shedding light on the link between cell wall composition, cellular behavior and whole-organ growth. PMID:27214583
Asati, Ankita; Satyanarayana, G N V; Patel, Devendra K
2017-09-01
Two low density organic solvents based liquid-liquid microextraction methods, namely Vortex assisted liquid-liquid microextraction based on solidification of floating organic droplet (VALLME-SFO) and Dispersive liquid-liquid microextraction based on solidification of floating organic droplet(DLLME-SFO) have been compared for the determination of multiclass analytes (pesticides, plasticizers, pharmaceuticals and personal care products) in river water samples by using liquid chromatography tandem mass spectrometry (LC-MS/MS). The effect of various experimental parameters on the efficiency of the two methods and their optimum values were studied with the aid of Central Composite Design (CCD) and Response Surface Methodology(RSM). Under optimal conditions, VALLME-SFO was validated in terms of limit of detection, limit of quantification, dynamic linearity range, determination of coefficient, enrichment factor and extraction recovery for which the respective values were (0.011-0.219ngmL -1 ), (0.035-0.723ngmL -1 ), (0.050-0.500ngmL -1 ), (R 2 =0.992-0.999), (40-56), (80-106%). However, when the DLLME-SFO method was validated under optimal conditions, the range of values of limit of detection, limit of quantification, dynamic linearity range, determination of coefficient, enrichment factor and extraction recovery were (0.025-0.377ngmL -1 ), (0.083-1.256ngmL -1 ), (0.100-1.000ngmL -1 ), (R 2 =0.990-0.999), (35-49), (69-98%) respectively. Interday and intraday precisions were calculated as percent relative standard deviation (%RSD) and the values were ≤15% for VALLME-SFO and DLLME-SFO methods. Both methods were successfully applied for determining multiclass analytes in river water samples. Copyright © 2017 Elsevier B.V. All rights reserved.
Mihailov, Rossen; Stoeva, Dilyana; Pencheva, Blagovesta; Pentchev, Eugeni
2018-03-01
In a number of cases the monitoring of patients with type I diabetes mellitus requires measurement of the exogenous insulin levels. For the purpose of a clinical investigation of the efficacy of a medical device for application of exogenous insulin aspart, a verification of the method for measurement of this synthetic analogue of the hormone was needed. The information in the available medical literature for the measurement of the different exogenous insulin analogs is insufficient. Thus, verification was required to be in compliance with the active standards in Republic of Bulgaria. A manufactured method developed for ADVIA Centaur XP Immunoassay, Siemens Healthcare, was used which we verified using standard solutions and a patient serum pool by adding the appropriate quantity exogenous insulin aspart. The method was verified in accordance with the bioanalytical method verification criteria and regulatory requirements for using a standard method: CLIA chemiluminescence immunoassay ADVIA Centaur® XP. The following parameters are determined and monitored: intra-day precision and accuracy, inter-day precision and accuracy, limit of detection and lower limit of quantification, linearity, analytical recovery. The routine application of the method for measurement of immunoreactive insulin using the analyzer ADVIA Centaur® XP is directed to the measurement of endogenous insulin. The method is applicable for measuring different types of exogenous insulin, including insulin aspart.
Comparisons of Wilks’ and Monte Carlo Methods in Response to the 10CFR50.46(c) Proposed Rulemaking
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Hongbin; Szilard, Ronaldo; Zou, Ling
The Nuclear Regulatory Commission (NRC) is proposing a new rulemaking on emergency core system/loss-of-coolant accident (LOCA) performance analysis. In the proposed rulemaking, designated as 10CFR50.46(c), the US NRC put forward an equivalent cladding oxidation criterion as a function of cladding pre-transient hydrogen content. The proposed rulemaking imposes more restrictive and burnup-dependent cladding embrittlement criteria; consequently nearly all the fuel rods in a reactor core need to be analyzed under LOCA conditions to demonstrate compliance to the safety limits. New analysis methods are required to provide a thorough characterization of the reactor core in order to identify the locations of themore » limiting rods as well as to quantify the safety margins under LOCA conditions. With the new analysis method presented in this work, the limiting transient case and the limiting rods can be easily identified to quantify the safety margins in response to the proposed new rulemaking. In this work, the best-estimate plus uncertainty (BEPU) analysis capability for large break LOCA with the new cladding embrittlement criteria using the RELAP5-3D code is established and demonstrated with a reduced set of uncertainty parameters. Both the direct Monte Carlo method and the Wilks’ nonparametric statistical method can be used to perform uncertainty quantification. Wilks’ method has become the de-facto industry standard to perform uncertainty quantification in BEPU LOCA analyses. Despite its widespread adoption by the industry, the use of small sample sizes to infer statement of compliance to the existing 10CFR50.46 rule, has been a major cause of unrealized operational margin in today’s BEPU methods. Moreover the debate on the proper interpretation of the Wilks’ theorem in the context of safety analyses is not fully resolved yet, even more than two decades after its introduction in the frame of safety analyses in the nuclear industry. This represents both a regulatory and application risk in rolling out new methods. With the 10CFR50.46(c) proposed rulemaking, the deficiencies of the Wilks’ approach are further exacerbated. The direct Monte Carlo approach offers a robust alternative to perform uncertainty quantification within the context of BEPU analyses. In this work, the Monte Carlo method is compared with the Wilks’ method in response to the NRC 10CFR50.46(c) proposed rulemaking.« less
Kierkegaard, Amelie; McLachlan, Michael S
2010-05-21
Decamethylcyclopentasiloxane (D(5)), a high production volume chemical used in personal care products, has been designated for regulation in Canada and is under review in the EU because of concerns about its persistence and potential for bioaccumulation in the environment. D(5) is a volatile compound expected to be found primarily in air, but there is little information on atmospheric concentrations due to the lack of sensitive analytical methods. Here a simple and sensitive method to determine D(5) in ambient air is presented. The challenge in the environmental analysis of D(5) is avoiding contamination. Our method is based on the high trapping efficiency of the sorbent Isolute ENV+, combined with a comparably high sampling rate. A small amount of sorbent (10 mg) is eluted in a small volume of n-hexane (0.1-0.6 mL), which is injected onto a GC/MS system without further processing. The simplicity of the method enables the use of a field blank for every sample to trace contamination. The method provides low limits of quantification (approximately 0.3 ng/m(3)), good repeatability and limited breakthrough (approximately 1%). By lowering the limit of quantification compared to published work by almost two orders of magnitude, it became possible to quantify D(5) in ambient air at locations remote from strong point sources. The concentrations at a rural Swedish site ranged from 0.7 to 8 ng/m(3) over a period of 4 months. 2010 Elsevier B.V. All rights reserved.
Alhazmi, Hassan A.; Alnami, Ahmed M.; Arishi, Mohammed A. A.; Alameer, Raad K.; Al Bratty, Mohammed; Rehman, Zia ur; Javed, Sadique A.; Arbab, Ismail A.
2017-01-01
The aim of this study was to develop and validate a fast and simple reversed-phase HPLC method for simultaneous determination of four cardiovascular agents—atorvastatin, simvastatin, telmisartan and irbesartan in bulk drugs and tablet oral dosage forms. The chromatographic separation was accomplished by using Symmetry C18 column (75 mm × 4.6 mm; 3.5 μ) with a mobile phase consisting of ammonium acetate buffer (10 mM; pH 4.0) and acetonitrile in a ratio 40:60 v/v. Flow rate was maintained at 1 mL/min up to 3.5 min, and then suddenly changed to 2 mL/min till the end of the run (7.5 min). The data was acquired using ultraviolet detector monitored at 220 nm. The method was validated for linearity, precision, accuracy and specificity. The developed method has shown excellent linearity (R2 > 0.999) over the concentration range of 1–16 µg/mL. The limits of detection (LODs) and limits of quantification (LOQs) were in the range of 0.189–0.190 and 0.603–0.630 µg/mL, respectively. Inter-day and intra-day accuracy and precision data were recorded in the acceptable limits. The new method has successfully been applied for quantification of all four drugs in their tablet dosage forms with percent recovery within 100 ± 2%. PMID:29257120
Talio, María C; Zambrano, Karen; Kaplan, Marcos; Acosta, Mariano; Gil, Raúl A; Luconi, Marta O; Fernández, Liliana P
2015-10-01
A new environmental friendly methodology based on fluorescent signal enhancement of rhodamine B dye is proposed for Pb(II) traces quantification using a preconcentration step based on the coacervation phenomenon. A cationic surfactant (cetyltrimethylammonium bromide, CTAB) and potassium iodine were chosen for this aim. The coacervate phase was collected on a filter paper disk and the solid surface fluorescence signal was determined in a spectrofluorometer. Experimental variables that influence on preconcentration step and fluorimetric sensitivity have been optimized using uni-variation assays. The calibration graph using zero th order regression was linear from 7.4×10(-4) to 3.4 μg L(-1) with a correlation coefficient of 0.999. Under the optimal conditions, a limit of detection of 2.2×10(-4) μg L(-1) and a limit of quantification of 7.4×10(-4) μg L(-1) were obtained. The method showed good sensitivity, adequate selectivity with good tolerance to foreign ions, and was applied to the determination of trace amounts of Pb(II) in refill solutions for e-cigarettes with satisfactory results validated by ICP-MS. The proposed method represents an innovative application of coacervation processes and of paper filters to solid surface fluorescence methodology. Copyright © 2015 Elsevier B.V. All rights reserved.
Do, Van-Khoai; Yamamoto, Masahiko; Taguchi, Shigeo; Takamura, Yuzuru; Surugaya, Naoki; Kuno, Takehiko
2018-06-01
A sensitive analytical method for determination of total cesium (Cs) in highly active liquid waste (HALW) by using modified liquid electrode plasma optical emission spectrometry (LEP-OES) is developed in this study. The instrument is modified to measure radioactive samples in a glove box. The effects of important factors, including pulsed voltage sequence and nitric acid concentration, on the emission of Cs are investigated. The limit of detection (LOD) and limit of quantification (LOQ) are 0.005 mg/L and 0.02 mg/L, respectively. The achieved LOD is one order lower than that of recently developed spectroscopic methods using liquid discharge plasma. The developed method is validated by subjecting a simulated HALW sample to inductively coupled plasma mass spectrometry (ICP-MS). The recoveries obtained from a spike-and-recovery test are 96-102%, implying good accuracy. The method is successfully applied to the quantification of Cs in a real HALW sample at the Tokai reprocessing plant in Japan. Apart from dilution and filtration of the HALW sample, no other pre-treatment process is required. The results agree well with the values obtained using gamma spectrometry. The developed method offers a reliable technique for rapid analysis of total Cs in HALW samples. Copyright © 2018 Elsevier B.V. All rights reserved.
Deconinck, E; Verlinde, K; Courselle, P; Beer, J O De
2012-02-05
A fully validated UHPLC-DAD method for the identification and quantification of pharmaceutical preparations, containing molecules frequently found in illegal slimming products (sibutramine, modafinil, ephedrine, nor-ephedrine, metformin, theophyllin, caffeine, diethylpropion and orlistat) was developed. The proposed method uses a Vision HT C18-B column (2 mm × 100 mm, 1.5 μm) with a gradient using an ammonium acetate buffer pH 5.0 as aqueous phase and acetonitrile as organic modifier. The obtained method was fully validated based on its measurement uncertainty (accuracy profile). Calibration lines for all components were linear within the studied ranges. The relative bias and the relative standard deviations for all components were respectively smaller than 3.0% and 1.5%, the β-expectation tolerance limits did not exceed the acceptance limits of 10% and the relative expanded uncertainties were smaller than 3% for all of the considered components. A UHPLC-DAD method was obtained for the identification and quantification of these kind of pharmaceutical preparations, which will significantly reduce analysis times and workload for the laboratories charged with the quality control of these preparations and which can, if necessary, be coupled to a MS-detector for a more thorough characterisation. Copyright © 2011 Elsevier B.V. All rights reserved.
Kim, Ho Jin
2016-01-01
A novel and simple method for detecting six water-soluble vitamins in animal feed using high performance liquid chromatography equipped with a photodiode array detector (HPLC/PDA) and ion-pairing reagent was developed. The chromatographic peaks of the six water-soluble vitamins were successfully identified by comparing their retention times and UV spectra with reference standards. The mobile phase was composed of buffers A (5 mM PICB-6 in 0.1% CH3COOH) and B (5 mM PICB-6 in 65% methanol). All peaks were detected using a wavelength of 270 nm. Method validation was performed in terms of linearity, sensitivity, selectivity, accuracy, and precision. The limits of detection (LODs) for the instrument employed in these experiments ranged from 25 to 197 μg/kg, and the limits of quantification (LOQs) ranged from 84 to 658 μg/kg. Average recoveries of the six water-soluble vitamins ranged from 82.3% to 98.9%. Method replication resulted in intraday and interday peak area variation of <5.6%. The developed method was specific and reliable and is therefore suitable for the routine analysis of water-soluble vitamins in animal feed.
Liu, Jia; Guo, Jinchao; Zhang, Haibo; Li, Ning; Yang, Litao; Zhang, Dabing
2009-11-25
Various polymerase chain reaction (PCR) methods were developed for the execution of genetically modified organism (GMO) labeling policies, of which an event-specific PCR detection method based on the flanking sequence of exogenous integration is the primary trend in GMO detection due to its high specificity. In this study, the 5' and 3' flanking sequences of the exogenous integration of MON89788 soybean were revealed by thermal asymmetric interlaced PCR. The event-specific PCR primers and TaqMan probe were designed based upon the revealed 5' flanking sequence, and the qualitative and quantitative PCR assays were established employing these designed primers and probes. In qualitative PCR, the limit of detection (LOD) was about 0.01 ng of genomic DNA corresponding to 10 copies of haploid soybean genomic DNA. In the quantitative PCR assay, the LOD was as low as two haploid genome copies, and the limit of quantification was five haploid genome copies. Furthermore, the developed PCR methods were in-house validated by five researchers, and the validated results indicated that the developed event-specific PCR methods can be used for identification and quantification of MON89788 soybean and its derivates.
Sun, Bing; Shen, Feng; McCalla, Stephanie E; Kreutz, Jason E; Karymov, Mikhail A; Ismagilov, Rustem F
2013-02-05
Here we used a SlipChip microfluidic device to evaluate the performance of digital reverse transcription-loop-mediated isothermal amplification (dRT-LAMP) for quantification of HIV viral RNA. Tests are needed for monitoring HIV viral load to control the emergence of drug resistance and to diagnose acute HIV infections. In resource-limited settings, in vitro measurement of HIV viral load in a simple format is especially needed, and single-molecule counting using a digital format could provide a potential solution. We showed here that when one-step dRT-LAMP is used for quantification of HIV RNA, the digital count is lower than expected and is limited by the yield of desired cDNA. We were able to overcome the limitations by developing a microfluidic protocol to manipulate many single molecules in parallel through a two-step digital process. In the first step we compartmentalize the individual RNA molecules (based on Poisson statistics) and perform reverse transcription on each RNA molecule independently to produce DNA. In the second step, we perform the LAMP amplification on all individual DNA molecules in parallel. Using this new protocol, we increased the absolute efficiency (the ratio between the concentration calculated from the actual count and the expected concentration) of dRT-LAMP 10-fold, from ∼2% to ∼23%, by (i) using a more efficient reverse transcriptase, (ii) introducing RNase H to break up the DNA:RNA hybrid, and (iii) adding only the BIP primer during the RT step. We also used this two-step method to quantify HIV RNA purified from four patient samples and found that in some cases, the quantification results were highly sensitive to the sequence of the patient's HIV RNA. We learned the following three lessons from this work: (i) digital amplification technologies, including dLAMP and dPCR, may give adequate dilution curves and yet have low efficiency, thereby providing quantification values that underestimate the true concentration. Careful validation is essential before a method is considered to provide absolute quantification; (ii) the sensitivity of dLAMP to the sequence of the target nucleic acid necessitates additional validation with patient samples carrying the full spectrum of mutations; (iii) for multistep digital amplification chemistries, such as a combination of reverse transcription with amplification, microfluidic devices may be used to decouple these steps from one another and to perform them under different, individually optimized conditions for improved efficiency.
Singh, Jaswant; Parkash, Jyoti; Kaur, Varinder; Singh, Raghubir
2017-10-05
A new method is reported for the quantification of some metallic components of healthcare products utilizing a Schiff base chelator derived from 2-hydroxyacetophenone and ethanolamine. The Schiff base chelator recognizes some metallic species such as iron, copper and zinc (important components of some healthcare products), and cadmium (common contaminant in healthcare products) giving colorimetric/fluorimetric response. It coordinates with Fe 2+ /Fe 3+ and Cu 2+ ions via ONO donor set and switches the colour to bright red, green and orange, respectively. Similarly, it switches 'ON' a fluorometric response when coordinates with Zn 2+ and Cd 2+ ions. In the present approach, detailed studies on the colorimetric and fluorimetric response of ONO Schiff base is investigated in detail. The Job plot for the complexation of ONO switch with various metal ions suggested formation of 1:1 (metal-chelator) complex with Fe 2+ , Fe 3+ , and Cu 2+ while 1:2 (metal-chelator) for Zn 2+ and Cd 2+ ions. The limit of detection, limit of quantification are 6.73, 18.0, 25.0, 0.65, 1.10μM and 27.0, 72.0, 100.0, 2.60 and 4.40μM for Fe 2+ , Fe 3+ , Cu 2+ , Zn 2+ and Cd 2+ ions, respectively. Under the optimized conditions, chelator was used for the quantification of important metals present in healthcare products via direct dissolution and furnace treatment during sample preparation. The results were found precise and accurate for both sample preparation techniques using the developed method. Copyright © 2017 Elsevier B.V. All rights reserved.
Arvia, Rosaria; Sollai, Mauro; Pierucci, Federica; Urso, Carmelo; Massi, Daniela; Zakrzewska, Krystyna
2017-08-01
Merkel cell polyomavirus (MCPyV) is associated with Merkel cell carcinoma and high viral load in the skin was proposed as a risk factor for the occurrence of this tumour. MCPyV DNA was detected, with lower frequency, in different skin cancers but since the viral load was usually low, the real prevalence of viral DNA could be underestimated. To evaluate the performance of two assays (qPCR and ddPCR) for MCPyV detection and quantification in formalin fixed paraffin embedded (FFPE) tissue samples. Both assays were designed to simultaneous detection and quantification of both MCPyV as well as house-keeping DNA in clinical samples. The performance of MCPyV quantification was investigated using serial dilutions of cloned target DNA. We also evaluated the applicability of both tests for the analysis of 76 FFPE cutaneous biopsies. The two approaches resulted equivalent with regard to the reproducibility and repeatability and showed a high degree of linearity in the dynamic range tested in the present study. Moreover, qPCR was able to quantify ≥10 5 copies per reaction, while the upper limit of ddPCR was 10 4 copies. There was not significant difference between viral load measured by the two methods The detection limit of both tests was 0,15 copies per reaction, however, the number of positive samples obtained by ddPCR was higher than that obtained by qPCR (45% and 37% respectively). The ddPCR represents a better method for detection of MCPyV in FFPE biopsies, mostly these containing low copies number of viral genome. Copyright © 2017 Elsevier B.V. All rights reserved.
Shin, Kyong-Oh; Lee, Yong-Moon
2016-01-01
Alkanolamines such as monoethanolamine (MEA), diethanolamine (DEA), and triethanolamine (TEA) are used as wetting agents in shampoos, lotions, creams, and other cosmetics. DEA is widely used to provide lather in shampoos and maintain a favorable consistency in lotions and creams. Although DEA is not harmful, it may react with other ingredients in the cosmetic formula after extended storage periods to form an extremely potent carcinogen called nitrosodiethanolamine (NDEA), which is readily absorbed through the skin and has been linked to the development of stomach, esophagus, liver, and bladder cancers. The purpose of this study was to develop a simultaneous quantification method for measurement of MEA, DEA, and TEA in cosmetic products. Liquid chromatography coupled tandem mass spectrometry (LC-MS/MS) was performed using a hydrophilic interaction liquid chromatography (HILIC) column with isocratic elution containing acetonitrile and 5 mM ammonium formate in water (88:12, v/v). Identification and quantification of alkanolamines were performed using MS/MS monitoring to assess the transition from precursor to product ion of MEA (m/z, 61.1 → 44.0), DEA (m/z, 106.1 → 88.0), TEA (m/z, 150.1 → 130.0), and the internal standard triethylamine (m/z, 102.2 → 58.0). Alkanolamines extractions were simplified using a single extraction with acetonitrile in the cosmetic matrix. Performance of the method was evaluated with quality parameters such as specificity, carry-over, linearity and calibration, correlation of determination (R(2)), detection limit, precision, accuracy, and recovery. Calibration curves of MEA (2.9-1000 ppb), DEA (1-1000 ppb), and TEA (1-1000 ppb) were constructed by plotting concentration versus peak-area ratio (analyte/internal standard with a correlation coefficient greater than 0.99). The intra- and inter-assay accuracy ranged from 92.92 to 101.15 % for all analytes. The intra- and inter-assay precision for MEA, DEA, and TEA showed all coefficients of variance were less than 9.38 % for QC samples. Limits of detection and limits of quantification were 2.00 and 15.63 ppb for MEA, 0.49 and 1.96 ppb for DEA, and 0.49 and 1.96 ppb for TEA, respectively. This novel quantification method simplified sample preparation and allowed accurate and reproducible quantification of alkanolamines in the ng/g cosmetic weight (ppb) range for several cosmetic products.
Manibalan, Kesavan; Mani, Veerappan; Chang, Pu-Chieh; Huang, Chih-Hung; Huang, Sheng-Tung; Marchlewicz, Kasper; Neethirajan, Suresh
2017-10-15
Hydrogen sulfide (H 2 S) was discovered as a third gasotransmitter in biological systems and recent years have seen a growing interest to understand its physiological and pathological functions. However, one major limiting factor is the lack of robust sensors to quantitatively track its production in real-time. We described a facile electrochemical assay based on latent redox probe approach for highly specific and sensitive quantification in living cells. Two chemical probes, Azido Benzyl ferrocene carbamate (ABFC) and N-alkyl Azido Benzyl ferrocene carbamate (NABFC) composed of azide trigger group were designed. H 2 S molecules specifically triggered the release of reporters from probes and the current response was monitored using graphene oxide film modified electrode as transducer. The detection limits are 0.32µM (ABFC) and 0.076µM (NABFC) which are comparable to those of current sensitive methods. The probes are successful in the determination of H 2 S spiked in whole human blood, fetal bovine serum, and E. coli. The continuous monitoring and quantification of endogenous H 2 S production in E. coli were successfully accomplished. This work lays first step stone towards real-time electrochemical quantification of endogenous H 2 S in living cells, thus hold great promise in the analytical aspects of H 2 S. Copyright © 2017 Elsevier B.V. All rights reserved.
Study of boron detection limit using the in-air PIGE set-up at LAMFI-USP
NASA Astrophysics Data System (ADS)
Moro, M. V.; Silva, T. F.; Trindade, G. F.; Added, N.; Tabacniks, M. H.
2014-11-01
The quantification of small amounts of boron in materials is of extreme importance in different areas of materials science. Boron is an important contaminant and also a silicon dopant in the semiconductor industry. Boron is also extensively used in nuclear power plants, either for neutron shielding or for safety control and boron is an essential nutrient for life, either vegetable or animal. The production of silicon solar cells, by refining metallurgical-grade silicon (MG-Si) requires the control and reduction of several silicon contaminants to very low concentration levels. Boron is one of the contaminants of solar-grade silicon (SG-Si) that must be controlled and quantified at sub-ppm levels. In the metallurgical purification, boron quantification is usually made by Inductive Coupled Plasma Mass Spectrometry, (ICP-MS) but the results need to be verified by an independent analytical method. In this work we present the results of the analysis of silicon samples by Particle Induced Gamma-Ray Emission (PIGE) aiming the quantification of low concentrations of boron. PIGE analysis was carried out using the in-air external beam line of the Laboratory for Materials Analysis with Ion Beans (LAMFI-USP) by the 10B ( p ,αγ(7Be nuclear reaction, and measuring the 429 keV γ-ray. The in-air PIGE measurements at LAMFI have a quantification limit of the order of 1016 at/cm2.
Couillerot, O; Poirier, M-A; Prigent-Combaret, C; Mavingui, P; Caballero-Mellado, J; Moënne-Loccoz, Y
2010-08-01
To assess the applicability of sequence characterized amplified region (SCAR) markers obtained from BOX, ERIC and RAPD fragments to design primers for real-time PCR quantification of the phytostimulatory maize inoculants Azospirillum brasilense UAP-154 and CFN-535 in the rhizosphere. Primers were designed based on strain-specific SCAR markers and were screened for successful amplification of target strain and absence of cross-reaction with other Azospirillum strains. The specificity of primers thus selected was verified under real-time PCR conditions using genomic DNA from strain collection and DNA from rhizosphere samples. The detection limit was 60 fg DNA with pure cultures and 4 x 10(3) (for UAP-154) and 4 x 10(4) CFU g(-1) (for CFN-535) in the maize rhizosphere. Inoculant quantification was effective from 10(4) to 10(8) CFU g(-1) soil. BOX-based SCAR markers were useful to find primers for strain-specific real-time PCR quantification of each A. brasilense inoculant in the maize rhizosphere. Effective root colonization is a prerequisite for successful Azospirillum phytostimulation, but cultivation-independent monitoring methods were lacking. The real-time PCR methods developed here will help understand the effect of environmental conditions on root colonization and phytostimulation by A. brasilense UAP-154 and CFN-535.
Integrative analysis with ChIP-seq advances the limits of transcript quantification from RNA-seq.
Liu, Peng; Sanalkumar, Rajendran; Bresnick, Emery H; Keleş, Sündüz; Dewey, Colin N
2016-08-01
RNA-seq is currently the technology of choice for global measurement of transcript abundances in cells. Despite its successes, isoform-level quantification remains difficult because short RNA-seq reads are often compatible with multiple alternatively spliced isoforms. Existing methods rely heavily on uniquely mapping reads, which are not available for numerous isoforms that lack regions of unique sequence. To improve quantification accuracy in such difficult cases, we developed a novel computational method, prior-enhanced RSEM (pRSEM), which uses a complementary data type in addition to RNA-seq data. We found that ChIP-seq data of RNA polymerase II and histone modifications were particularly informative in this approach. In qRT-PCR validations, pRSEM was shown to be superior than competing methods in estimating relative isoform abundances within or across conditions. Data-driven simulations suggested that pRSEM has a greatly decreased false-positive rate at the expense of a small increase in false-negative rate. In aggregate, our study demonstrates that pRSEM transforms existing capacity to precisely estimate transcript abundances, especially at the isoform level. © 2016 Liu et al.; Published by Cold Spring Harbor Laboratory Press.
Viidanoja, Jyrki
2015-02-27
A new method for quantification of short chain C1-C6 carboxylic acids in vegetable oils and fats by employing Liquid Chromatography Mass Spectrometry (LC-MS) has been developed. The method requires minor sample preparation and applies non-conventional Electrospray Ionization (ESI) liquid phase chemistry. Samples are first dissolved in chloroform and then extracted using water that has been spiked with stable isotope labeled internal standards that are used for signal normalization and absolute quantification of selected acids. The analytes are separated using Ion Exclusion Chromatography (IEC) and detected with Electrospray Ionization Mass Spectrometry (ESI-MS) as deprotonated molecules. Prior to ionization the eluent that contains hydrochloric acid is modified post-column to ensure good ionization efficiency of the analytes. The averaged within run precision and between run precision were generally lower than 8%. The accuracy was between 85 and 115% for most of the analytes. The Lower Limit of Quantification (LLOQ) ranged from 0.006 to 7mg/kg. It is shown that this method offers good selectivity in cases where UV detection fails to produce reliable results. Copyright © 2015 Elsevier B.V. All rights reserved.
Kittelmann, Jörg; Ottens, Marcel; Hubbuch, Jürgen
2015-04-15
High-throughput batch screening technologies have become an important tool in downstream process development. Although continuative miniaturization saves time and sample consumption, there is yet no screening process described in the 384-well microplate format. Several processes are established in the 96-well dimension to investigate protein-adsorbent interactions, utilizing between 6.8 and 50 μL resin per well. However, as sample consumption scales with resin volumes and throughput scales with experiments per microplate, they are limited in costs and saved time. In this work, a new method for in-well resin quantification by optical means, applicable in the 384-well format, and resin volumes as small as 0.1 μL is introduced. A HTS batch isotherm process is described, utilizing this new method in combination with optical sample volume quantification for screening of isotherm parameters in 384-well microplates. Results are qualified by confidence bounds determined by bootstrap analysis and a comprehensive Monte Carlo study of error propagation. This new approach opens the door to a variety of screening processes in the 384-well format on HTS stations, higher quality screening data and an increase in throughput. Copyright © 2015 Elsevier B.V. All rights reserved.
Hame, Yrjo; Angelini, Elsa D; Hoffman, Eric A; Barr, R Graham; Laine, Andrew F
2014-07-01
The extent of pulmonary emphysema is commonly estimated from CT scans by computing the proportional area of voxels below a predefined attenuation threshold. However, the reliability of this approach is limited by several factors that affect the CT intensity distributions in the lung. This work presents a novel method for emphysema quantification, based on parametric modeling of intensity distributions and a hidden Markov measure field model to segment emphysematous regions. The framework adapts to the characteristics of an image to ensure a robust quantification of emphysema under varying CT imaging protocols, and differences in parenchymal intensity distributions due to factors such as inspiration level. Compared to standard approaches, the presented model involves a larger number of parameters, most of which can be estimated from data, to handle the variability encountered in lung CT scans. The method was applied on a longitudinal data set with 87 subjects and a total of 365 scans acquired with varying imaging protocols. The resulting emphysema estimates had very high intra-subject correlation values. By reducing sensitivity to changes in imaging protocol, the method provides a more robust estimate than standard approaches. The generated emphysema delineations promise advantages for regional analysis of emphysema extent and progression.
Flouda, Konstantina; Dersch, Julie Maria; Gabel-Jensen, Charlotte; Stürup, Stefan; Misra, Sougat; Björnstedt, Mikael; Gammelgaard, Bente
2016-03-01
The paper presents an analytical method for quantification of low molecular weight (LMW) selenium compounds in human plasma based on liquid chromatography inductively coupled plasma mass spectrometry (LC-ICP-MS) and post column isotope dilution-based quantification. Prior to analysis, samples were ultrafiltrated using a cut-off value of 3000 Da. The method was validated in aqueous solution as well as plasma using standards of selenomethionine (SeMet), Se-methylselenocysteine (MeSeCys), selenite, and the selenosugar Se-methylseleno-N-acetylgalactosamine (SeGal) for linearity, precision, recoveries, and limits of detection and quantitation with satisfactory results. The method was applied for analysis of a set of plasma samples from cancer patients receiving selenite treatment in a clinical trial. Three LMW selenium compounds were observed. The main compounds, SeGal and selenite were tentatively identified by retention time matching with standards in different chromatographic systems, while the third minor compound was not identified. The identity of the selenosugar was verified by ESI-MS-MS product ion scanning, while selenite was identified indirectly as the glutathione (GSH) reaction product, GS-Se-SG.
2017-02-02
Corresponding Author Abstract Accurate virus quantification is sought, but a perfect method still eludes the scientific community. Electron...unlimited. UNCLASSIFIED 2 provides morphology data and counts all viral particles, including partial or noninfectious particles; however, EM methods ...consistent, reproducible virus quantification method called Scanning Transmission Electron Microscopy – Virus Quantification (STEM-VQ) which simplifies
Yan, Jiajie; Thomson, Justin K.; Wu, Xiaomin; Zhao, Weiwei; Pollard, Andrew E.; Ai, Xun
2014-01-01
Background Gap junctions (GJs) are the principal membrane structures that conduct electrical impulses between cardiac myocytes while interstitial collagen (IC) can physically separate adjacent myocytes and limit cell-cell communication. Emerging evidence suggests that both GJ and interstitial structural remodeling are linked to cardiac arrhythmia development. However, automated quantitative identification of GJ distribution and IC deposition from microscopic histological images has proven to be challenging. Such quantification is required to improve the understanding of functional consequences of GJ and structural remodeling in cardiac electrophysiology studies. Methods and Results Separate approaches were employed for GJ and IC identification in images from histologically stained tissue sections obtained from rabbit and human atria. For GJ identification, we recognized N-Cadherin (N-Cad) as part of the gap junction connexin 43 (Cx43) molecular complex. Because N-Cad anchors Cx43 on intercalated discs (ID) to form functional GJ channels on cell membranes, we computationally dilated N-Cad pixels to create N-Cad units that covered all ID-associated Cx43 pixels on Cx43/N-Cad double immunostained confocal images. This approach allowed segmentation between ID-associated and non-ID-associated Cx43. Additionally, use of N-Cad as a unique internal reference with Z-stack layer-by-layer confocal images potentially limits sample processing related artifacts in Cx43 quantification. For IC quantification, color map thresholding of Masson's Trichrome blue stained sections allowed straightforward and automated segmentation of collagen from non-collagen pixels. Our results strongly demonstrate that the two novel image-processing approaches can minimize potential overestimation or underestimation of gap junction and structural remodeling in healthy and pathological hearts. The results of using the two novel methods will significantly improve our understanding of the molecular and structural remodeling associated functional changes in cardiac arrhythmia development in aged and diseased hearts. PMID:25105669
Tsai, I-Lin; Kuo, Ching-Hua; Sun, Hsin-Yun; Chuang, Yu-Chung; Chepyala, Divyabharathi; Lin, Shu-Wen; Tsai, Yun-Jung
2017-10-25
Outbreaks of multidrug-resistant Gram-negative bacterial infections have been reported worldwide. Colistin, an antibiotic with known nephrotoxicity and neurotoxicity, is now being used to treat multidrug-resistant Gram-negative strains. In this study, we applied an on-spot internal standard addition approach coupled with an ultra high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to quantify colistin A and B from dried blood spots (DBSs). Only 15μL of whole blood was required for each sample. An internal standard with the same yield of extraction recoveries as colistin was added to the spot before sample extraction for accurate quantification. Formic acid in water (0.15%) with an equal volume of acetonitrile (50:50v/v) was used as the extraction solution. With the optimized extraction process and LC-MS/MS conditions, colistin A and B could be quantified from a DBS with respective limits of quantification of 0.13 and 0.27μgmL -1 , and the retention times were < 2min. The relative standard deviations of within-run and between-run precisions for peak area ratios were all < 17.3%. Accuracies were 91.5-111.2% for lower limit of quantification, low, medium, and high QC samples. The stability of the easily hydrolyzed prodrug, colistin methanesulfonate, was investigated in DBSs. Less than 4% of the prodrug was found to be hydrolyzed in DBSs at room temperature after 48h. The developed method applied an on-spot internal standard addition approach which benefited the precision and accuracy. Results showed that DBS sampling coupled with the sensitive LC-MS/MS method has the potential to be an alternative approach for colistin quantification, where the bias of prodrug hydrolysis in liquid samples is decreased. Copyright © 2017 Elsevier B.V. All rights reserved.
Kaur, Jaspreet; Srinivasan, K. K.; Joseph, Alex; Gupta, Abhishek; Singh, Yogendra; Srinivas, Kona S.; Jain, Garima
2010-01-01
Objective: Venlafaxine,hydrochloride is a structurally novel phenethyl bicyclic antidepressant, and is usually categorized as a serotonin–norepinephrine reuptake inhibitor (SNRI) but it has been referred to as a serotonin–norepinephrine–dopamine reuptake inhibitor. It inhibits the reuptake of dopamine. Venlafaxine HCL is widely prescribed in the form of sustained release formulations. In the current article we are reporting the development and validation of a fast and simple stability indicating, isocratic high performance liquid chromatographic (HPLC) method for the determination of venlafaxine hydrochloride in sustained release formulations. Materials and Methods: The quantitative determination of venlafaxine hydrochloride was performed on a Kromasil C18 analytical column (250 × 4.6 mm i.d., 5 μm particle size) with 0.01 M phosphate buffer (pH 4.5): methanol (40: 60) as a mobile phase, at a flow rate of 1.0 ml/min. For HPLC methods, UV detection was made at 225 nm. Results: During method validation, parameters such as precision, linearity, accuracy, stability, limit of quantification and detection and specificity were evaluated, which remained within acceptable limits. Conclusions: The method has been successfully applied for the quantification and dissolution profiling of Venlafaxine HCL in sustained release formulation. The method presents a simple and reliable solution for the routine quantitative analysis of Venlafaxine HCL. PMID:21814426
Development and validation of an open source quantification tool for DSC-MRI studies.
Gordaliza, P M; Mateos-Pérez, J M; Montesinos, P; Guzmán-de-Villoria, J A; Desco, M; Vaquero, J J
2015-03-01
This work presents the development of an open source tool for the quantification of dynamic susceptibility-weighted contrast-enhanced (DSC) perfusion studies. The development of this tool is motivated by the lack of open source tools implemented on open platforms to allow external developers to implement their own quantification methods easily and without the need of paying for a development license. This quantification tool was developed as a plugin for the ImageJ image analysis platform using the Java programming language. A modular approach was used in the implementation of the components, in such a way that the addition of new methods can be done without breaking any of the existing functionalities. For the validation process, images from seven patients with brain tumors were acquired and quantified with the presented tool and with a widely used clinical software package. The resulting perfusion parameters were then compared. Perfusion parameters and the corresponding parametric images were obtained. When no gamma-fitting is used, an excellent agreement with the tool used as a gold-standard was obtained (R(2)>0.8 and values are within 95% CI limits in Bland-Altman plots). An open source tool that performs quantification of perfusion studies using magnetic resonance imaging has been developed and validated using a clinical software package. It works as an ImageJ plugin and the source code has been published with an open source license. Copyright © 2015 Elsevier Ltd. All rights reserved.
Modern Instrumental Methods in Forensic Toxicology*
Smith, Michael L.; Vorce, Shawn P.; Holler, Justin M.; Shimomura, Eric; Magluilo, Joe; Jacobs, Aaron J.; Huestis, Marilyn A.
2009-01-01
This article reviews modern analytical instrumentation in forensic toxicology for identification and quantification of drugs and toxins in biological fluids and tissues. A brief description of the theory and inherent strengths and limitations of each methodology is included. The focus is on new technologies that address current analytical limitations. A goal of this review is to encourage innovations to improve our technological capabilities and to encourage use of these analytical techniques in forensic toxicology practice. PMID:17579968
Mc Fadden, Kim; Gillespie, John; Carney, Brian; O'Driscoll, Daniel
2006-07-07
A rapid and selective HPLC method using monolithic columns was developed for the separation and quantification of the principal amphetamines in ecstasy tablets. Three monolithic (Chromolith RP18e) columns of different lengths (25, 50 and 100 mm) were assessed. Validation studies including linearity, selectivity, precision, accuracy and limit of detection and quantification were carried out using the Chromolith SpeedROD, RP-18e, 50 mm x 4.6 mm column. Column backpressure and van Deemter plots demonstrated that monolithic columns provide higher efficiency at higher flow rates when compared to particulate columns without the loss of peak resolution. Application of the monolithic column to a large number of ecstasy tablets seized in Ireland ensured its suitability for the routine analysis of ecstasy tablets.
Savazzini, Federica; Longa, Claudia Maria Oliveira; Pertot, Ilaria; Gessler, Cesare
2008-05-01
Trichoderma (Hypocreales, Ascomycota) is a widespread genus in nature and several Trichoderma species are used in industrial processes and as biocontrol agents against crop diseases. It is very important that the persistence and spread of microorganisms released on purpose into the environment are accurately monitored. Real-time PCR methods for genus/species/strain identification of microorganisms are currently being developed to overcome the difficulties of classical microbiological and enzymatic methods for monitoring these populations. The aim of the present study was to develop and validate a specific real-time PCR-based method for detecting Trichoderma atroviride SC1 in soil. We developed a primer and TaqMan probe set constructed on base mutations in an endochitinase gene. This tool is highly specific for the detection and quantification of the SC1 strain. The limits of detection and quantification calculated from the relative standard deviation were 6000 and 20,000 haploid genome copies per gram of soil. Together with the low throughput time associated with this procedure, which allows the evaluation of many soil samples within a short time period, these results suggest that this method could be successfully used to trace the fate of T. atroviride SC1 applied as an open-field biocontrol agent.
Quantification of Humic Substances in Natural Water Using Nitrogen-Doped Carbon Dots.
Guan, Yan-Fang; Huang, Bao-Cheng; Qian, Chen; Yu, Han-Qing
2017-12-19
Dissolved organic matter (DOM) is ubiquitous in aqueous environments and plays a significant role in pollutant mitigation, transformation and organic geochemical circulation. DOM is also capable of forming carcinogenic byproducts in the disinfection treatment processes of drinking water. Thus, efficient methods for DOM quantification are highly desired. In this work, a novel sensor for rapid and selective detection of humic substances (HS), a key component of DOM, based on fluorescence quenching of nitrogen-doped carbon quantum dots was developed. The experimental results show that the HS detection range could be broadened to 100 mg/L with a detection limit of 0.2 mg/L. Moreover, the detection was effective within a wide pH range of 3.0 to 12.0, and the interferences of ions on the HS measurement were negligible. A good detection result for real surface water samples further validated the feasibility of the developed detection method. Furthermore, a nonradiation electron transfer mechanism for quenching the nitrogen-doped carbon-dots fluorescence by HS was elucidated. In addition, we prepared a test paper and proved its effectiveness. This work provides a new efficient method for the HS quantification than the frequently used modified Lowry method in terms of sensitivity and detection range.
Appel, David I.; Brinda, Bryan; Markowitz, John S.; Newcorn, Jeffrey H.; Zhu, Hao-Jie
2012-01-01
A simple, rapid and sensitive method for quantification of atomoxetine by liquid chromatography- tandem mass spectrometry (LC-MS/MS) was developed. This assay represents the first LC-MS/MS quantification method for atomoxetine utilizing electrospray ionization. Deuterated atomoxetine (d3-atomoxetine) was adopted as the internal standard. Direct protein precipitation was utilized for sample preparation. This method was validated for both human plasma and in vitro cellular samples. The lower limit of quantification was 3 ng/ml and 10 nM for human plasma and cellular samples, respectively. The calibration curves were linear within the ranges of 3 ng/ml to 900 ng/ml and 10 nM to 10 μM for human plasma and cellular samples, respectively (r2 > 0.999). The intra- and inter-day assay accuracy and precision were evaluated using quality control samples at 3 different concentrations in both human plasma and cellular lysate. Sample run stability, assay selectivity, matrix effect, and recovery were also successfully demonstrated. The present assay is superior to previously published LC-MS and LC-MS/MS methods in terms of sensitivity or the simplicity of sample preparation. This assay is applicable to the analysis of atomoxetine in both human plasma and in vitro cellular samples. PMID:22275222
Mistri, Hiren N; Jangid, Arvind G; Pudage, Ashutosh; Shrivastav, Pranav
2008-03-15
A simple, selective and sensitive isocratic HPLC method with triple quadrupole mass spectrometry detection has been developed and validated for simultaneous quantification of zopiclone and its metabolites in human plasma. The analytes were extracted using solid phase extraction, separated on Symmetry shield RP8 column (150 mm x 4.6 mm i.d., 3.5 microm particle size) and detected by tandem mass spectrometry with a turbo ion spray interface. Metaxalone was used as an internal standard. The method had a chromatographic run time of 4.5 min and linear calibration curves over the concentration range of 0.5-150 ng/mL for both zopiclone and N-desmethyl zopiclone and 1-150 ng/mL for zopiclone-N-oxide. The intra-batch and inter-batch accuracy and precision evaluated at lower limit of quantification and quality control levels were within 89.5-109.1% and 3.0-14.7%, respectively, for all the analytes. The recoveries calculated for the analytes and internal standard were > or = 90% from spiked plasma samples. The validated method was successfully employed for a comparative bioavailability study after oral administration of 7.5 mg zopiclone (test and reference) to 16 healthy volunteers under fasted condition.
Hsu, Wei-Yi; Chen, Ching-Ming; Tsai, Fuu-Jen; Lai, Chien-Chen
2013-05-01
Urinary homovanillic acid (HVA)/vanillylmandelic acid (VMA), orotic acid (OA), and homogentisic acid (HGA) are diagnostic biomarkers of neuroblastoma, ornithine carbamoyl transferase deficiency (OCTD), and alkaptonuria (AKU), respectively. In this study, a high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for simultaneous quantification of HVA, VMA, OA, and HGA in urine. After sample preparation, which involved only the dilution procedure, samples were quantified by LC-MS/MS. Full-scan MS/MS mode enabled the urinary markers to be quantified with a high degree of specificity and sensitivity. Rather than using a separate enzymatic method to normalize the concentration of creatinine in urine, we quantified the level of creatinine in urine in one LC-MS run. The limits of detection were 10 μg/l for HGA, 25 μg/l for HVA/VMA, and 50 μg/l for OA with a single-to-noise ratio of 3; the limits of quantification were 50 μg/l for HVA and HGA, 100 μg/l for VMA, and 250 μg/l for OA. The linear dynamic range for quantification of the analytes covered 2 to 3 orders of magnitude, depending on the analyte. The relative standard deviation of the developed LC-MS/MS method was less than 4% for the intra-day validation and 10% for the inter-day validation. The results show that our LC-MS/MS technique is a highly sensitive and rapid method for screening for biomarkers that are diagnostic of three metabolic diseases. Copyright © 2012 Elsevier B.V. All rights reserved.
Wei, Xiaojia Eric; Korth, John; Brown, Simon H J; Mitchell, Todd W; Truscott, Roger J W; Blanksby, Stephen J; Willcox, Mark D P; Zhao, Zhenjun
2013-12-09
To establish a simple and rapid analytical method, based on direct insertion/electron ionization-mass spectrometry (DI/EI-MS), for measuring free cholesterol in tears from humans and rabbits. A stable-isotope dilution protocol employing DI/EI-MS in selected ion monitoring mode was developed and validated. It was used to quantify the free cholesterol content in human and rabbit tear extracts. Tears were collected from adult humans (n = 15) and rabbits (n = 10) and lipids extracted. Screening, full-scan (m/z 40-600) DI/EI-MS analysis of crude tear extracts showed that diagnostic ions located in the mass range m/z 350 to 400 were those derived from free cholesterol, with no contribution from cholesterol esters. DI/EI-MS data acquired using selected ion monitoring (SIM) were analyzed for the abundance ratios of diagnostic ions with their stable isotope-labeled analogues arising from the D6-cholesterol internal standard. Standard curves of good linearity were produced and an on-probe limit of detection of 3 ng (at 3:1 signal to noise) and limit of quantification of 8 ng (at 10:1 signal to noise). The concentration of free cholesterol in human tears was 15 ± 6 μg/g, which was higher than in rabbit tears (10 ± 5 μg/g). A stable-isotope dilution DI/EI-SIM method for free cholesterol quantification without prior chromatographic separation was established. Using this method demonstrated that humans have higher free cholesterol levels in their tears than rabbits. This is in agreement with previous reports. This paper provides a rapid and reliable method to measure free cholesterol in small-volume clinical samples.
Dziadosz, Marek
2018-01-01
The aim of this work was to develop a fast, cost-effective and time-saving liquid chromatography-tandem mass spectrometry (LC-MS/MS) analytical method for the analysis of ethylene glycol (EG) in human serum. For these purposes, the formation/fragmentation of an EG adduct ion with sodium and sodium acetate was applied in the positive electrospray mode for signal detection. Adduct identification was performed with appropriate infusion experiments based on analyte solutions prepared in different concentrations. Corresponding analyte adduct ions and adduct ion fragments could be identified both for EG and the deuterated internal standard (EG-D4). Protein precipitation was used as sample preparation. The analysis of the supernatant was performed with a Luna 5μm C18 (2) 100A, 150mm×2mm analytical column and a mobile phase consisting of 95% A (H 2 O/methanol=95/5, v/v) and 5% B (H 2 O/methanol=3/97, v/v), both with 10mmolL -1 ammonium acetate and 0.1% acetic acid. Method linearity was examined in the range of 100-4000μg/mL and the calculated limit of detection/quantification was 35/98μg/mL. However, on the basis of the signal to noise ratio, quantification was recommended at a limit of 300μg/mL. Additionally, the examined precision, accuracy, stability, selectivity and matrix effect demonstrated that the method is a practicable alternative for EG quantification in human serum. In comparison to other methods based on liquid chromatography, the strategy presented made for the first time the EG analysis without analyte derivatisation possible. Copyright © 2017 Elsevier B.V. All rights reserved.
Abate, Teresa; Cayo, Nelly M.; Parrado, Rudy; Bello, Zoraida Diaz; Velazquez, Elsa; Muñoz-Calderon, Arturo; Juiz, Natalia A.; Basile, Joaquín; Garcia, Lineth; Riarte, Adelina; Nasser, Julio R.; Ocampo, Susana B.; Yadon, Zaida E.; Torrico, Faustino; de Noya, Belkisyole Alarcón; Ribeiro, Isabela; Schijman, Alejandro G.
2013-01-01
Background The analytical validation of sensitive, accurate and standardized Real-Time PCR methods for Trypanosoma cruzi quantification is crucial to provide a reliable laboratory tool for diagnosis of recent infections as well as for monitoring treatment efficacy. Methods/Principal Findings We have standardized and validated a multiplex Real-Time quantitative PCR assay (qPCR) based on TaqMan technology, aiming to quantify T. cruzi satellite DNA as well as an internal amplification control (IAC) in a single-tube reaction. IAC amplification allows rule out false negative PCR results due to inhibitory substances or loss of DNA during sample processing. The assay has a limit of detection (LOD) of 0.70 parasite equivalents/mL and a limit of quantification (LOQ) of 1.53 parasite equivalents/mL starting from non-boiled Guanidine EDTA blood spiked with T. cruzi CL-Brener stock. The method was evaluated with blood samples collected from Chagas disease patients experiencing different clinical stages and epidemiological scenarios: 1- Sixteen Venezuelan patients from an outbreak of oral transmission, 2- Sixty three Bolivian patients suffering chronic Chagas disease, 3- Thirty four Argentinean cases with chronic Chagas disease, 4- Twenty seven newborns to seropositive mothers, 5- A seronegative receptor who got infected after transplantation with a cadaveric kidney explanted from an infected subject. Conclusions/Significance The performing parameters of this assay encourage its application to early assessment of T. cruzi infection in cases in which serological methods are not informative, such as recent infections by oral contamination or congenital transmission or after transplantation with organs from seropositive donors, as well as for monitoring Chagas disease patients under etiological treatment. PMID:23350002
Shin, Kyung-Hwa; Lee, Hyun-Ji; Chang, Chulhun L; Kim, Hyung-Hoi
2018-04-01
Hepatitis B virus (HBV) DNA levels are used to predict the response to therapy, determine therapy initiation, monitor resistance to therapy, and establish treatment success. To verify the performance of the cobas HBV test using the cobas 4800 system for HBV DNA quantification and to compare the HBV DNA quantification ability between the cobas HBV test and COBAS AmpliPrep/COBAS TaqMan HBV version 2.0 (CAP/CTM v2.0). The precision, linearity, and limit of detection of the cobas HBV test were evaluated using the 4th World Health Organization International Standard material and plasma samples. Clinical samples that yielded quantitative results using the CAP/CTM v2.0 and cobas HBV tests were subjected to correlational analysis. Three hundred forty-nine samples were subjected to correlational analysis, among which 114 samples showed results above the lower limit of quantification. Comparable results were obtained ([cobas HBV test] = 1.038 × [CAP/CTM v2.0]-0.173, r = 0.914) in 114 samples, which yielded values above the lower limit of quantification. The results for 86.8% of the samples obtained using the cobas HBV test were within 0.5 log 10 IU/mL of the CAP/CTM v2.0 results. The total precision values against the low and high positive controls were 1.4% (mean level: 2.25 log 10 IU/mL) and 3.2% (mean level: 6.23 log 10 IU/mL), respectively. The cobas HBV test demonstrated linearity (1.15-6.75 log 10 IU/mL, y = 0.95 × 6 + 0.17, r 2 = 0.994). The cobas HBV test showed good correlation with CAP/CTM v2.0, and had good precision and an acceptable limit of detection. The cobas HBV test using the cobas 4800 is a reliable method for quantifying HBV DNA levels in the clinical setting. Copyright © 2018. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Tian, Gang; Zhang, Xiao-Qing; Zhu, Ming-Song; Zhang, Zhong; Shi, Zheng-Hu; Ding, Min
2016-03-01
Simple, rapid and accurate detection of ethanol concentration in blood is very crucial in the diagnosis and management of potential acute ethanol intoxication patients. A novel electrochemical detection method was developed for the quantification of ethanol in human plasma with disposable unmodified screen-printed carbon electrode (SPCE) without sample preparation procedure. Ethanol was detected indirectly by the reaction product of ethanol dehydrogenase (ADH) and cofactor nicotinamide adenine dinucleotide (NAD+). Method validation indicated good quantitation precisions with intra-day and inter-day relative standard deviations of ≤9.4% and 8.0%, respectively. Ethanol concentration in plasma is linear ranging from 0.10 to 3.20 mg/mL, and the detection limit is 40.0 μg/mL (S/N > 3). The method shows satisfactory correlation with the reference method of headspace gas chromatography in twenty human plasma samples (correlation coefficient 0.9311). The proposed method could be applied to diagnose acute ethanol toxicity or ethanol-related death.
Tian, Gang; Zhang, Xiao-Qing; Zhu, Ming-Song; Zhang, Zhong; Shi, Zheng-Hu; Ding, Min
2016-01-01
Simple, rapid and accurate detection of ethanol concentration in blood is very crucial in the diagnosis and management of potential acute ethanol intoxication patients. A novel electrochemical detection method was developed for the quantification of ethanol in human plasma with disposable unmodified screen-printed carbon electrode (SPCE) without sample preparation procedure. Ethanol was detected indirectly by the reaction product of ethanol dehydrogenase (ADH) and cofactor nicotinamide adenine dinucleotide (NAD+). Method validation indicated good quantitation precisions with intra-day and inter-day relative standard deviations of ≤9.4% and 8.0%, respectively. Ethanol concentration in plasma is linear ranging from 0.10 to 3.20 mg/mL, and the detection limit is 40.0 μg/mL (S/N > 3). The method shows satisfactory correlation with the reference method of headspace gas chromatography in twenty human plasma samples (correlation coefficient 0.9311). The proposed method could be applied to diagnose acute ethanol toxicity or ethanol-related death. PMID:27006081
Joyce, Richard; Kuziene, Viktorija; Zou, Xin; Wang, Xueting; Pullen, Frank; Loo, Ruey Leng
2016-01-01
An ultra-performance liquid chromatography quadrupole time of flight mass spectrometry (UPLC-qTOF-MS) method using hydrophilic interaction liquid chromatography was developed and validated for simultaneous quantification of 18 free amino acids in urine with a total acquisition time including the column re-equilibration of less than 18 min per sample. This method involves simple sample preparation steps which consisted of 15 times dilution with acetonitrile to give a final composition of 25 % aqueous and 75 % acetonitrile without the need of any derivatization. The dynamic range for our calibration curve is approximately two orders of magnitude (120-fold from the lowest calibration curve point) with good linearity (r (2) ≥ 0.995 for all amino acids). Good separation of all amino acids as well as good intra- and inter-day accuracy (<15 %) and precision (<15 %) were observed using three quality control samples at a concentration of low, medium and high range of the calibration curve. The limits of detection (LOD) and lower limit of quantification of our method were ranging from approximately 1-300 nM and 0.01-0.5 µM, respectively. The stability of amino acids in the prepared urine samples was found to be stable for 72 h at 4 °C, after one freeze thaw cycle and for up to 4 weeks at -80 °C. We have applied this method to quantify the content of 18 free amino acids in 646 urine samples from a dietary intervention study. We were able to quantify all 18 free amino acids in these urine samples, if they were present at a level above the LOD. We found our method to be reproducible (accuracy and precision were typically <10 % for QCL, QCM and QCH) and the relatively high sample throughput nature of this method potentially makes it a suitable alternative for the analysis of urine samples in clinical setting.
A, Vijaya Bhaskar Reddy; Yusop, Zulkifli; Jaafar, Jafariah; Aris, Azmi B; Majid, Zaiton A; Umar, Khalid; Talib, Juhaizah
2016-09-05
In this study a sensitive and selective gradient reverse phase UPLC-MS/MS method was developed for the simultaneous determination of six process related impurities viz., Imp-I, Imp-II, Imp-III, Imp-IV, Imp-V and Imp-VI in darunavir. The chromatographic separation was performed on Acquity UPLC BEH C18 (50 mm×2.1mm, 1.7μm) column using gradient elution of acetonitrile-methanol (80:20, v/v) and 5.0mM ammonium acetate containing 0.01% formic acid at a flow rate of 0.4mL/min. Both negative and positive electrospray ionization (ESI) modes were operated simultaneously using multiple reaction monitoring (MRM) for the quantification of all six impurities in darunavir. The developed method was fully validated following ICH guidelines with respect to specificity, linearity, limit of detection (LOD), limit of quantification (LOQ), accuracy, precision, robustness and sample solution stability. The method was able to quantitate Imp-I, Imp-IV, Imp-V at 0.3ppm and Imp-II, Imp-III, and Imp-VI at 0.2ppm with respect to 5.0mg/mL of darunavir. The calibration curves showed good linearity over the concentration range of LOQ to 250% for all six impurities. The correlation coefficient obtained was >0.9989 in all the cases. The accuracy of the method lies between 89.90% and 104.60% for all six impurities. Finally, the method has been successfully applied for three formulation batches of darunavir to determine the above mentioned impurities, however no impurity was found beyond the LOQ. This method is a good quality control tool for the trace level quantification of six process related impurities in darunavir during its synthesis. Copyright © 2016 Elsevier B.V. All rights reserved.
Lee, Seung Soo; Lee, Youngjoo; Kim, Namkug; Kim, Seong Who; Byun, Jae Ho; Park, Seong Ho; Lee, Moon-Gyu; Ha, Hyun Kwon
2011-06-01
To compare the accuracy of four chemical shift magnetic resonance imaging (MRI) (CS-MRI) analysis methods and MR spectroscopy (MRS) with and without T2-correction in fat quantification in the presence of excess iron. CS-MRI with six opposed- and in-phase acquisitions and MRS with five-echo acquisitions (TEs of 20, 30, 40, 50, 60 msec) were performed at 1.5 T on phantoms containing various fat fractions (FFs), on phantoms containing various iron concentrations, and in 18 patients with chronic liver disease. For CS-MRI, FFs were estimated with the dual-echo method, with two T2*-correction methods (triple- and multiecho), and with multiinterference methods that corrected for both T2* and spectral interference effects. For MRS, FF was estimated without T2-correction (single-echo MRS) and with T2-correction (multiecho MRS). In the phantoms, T2*- or T2-correction methods for CS-MRI and MRS provided unbiased estimations of FFs (mean bias, -1.1% to 0.5%) regardless of iron concentration, whereas the dual-echo method (-5.5% to -8.4%) and single-echo MRS (12.1% to 37.3%) resulted in large biases in FFs. In patients, the FFs estimated with triple-echo (R = 0.98), multiecho (R = 0.99), and multiinterference (R = 0.99) methods had stronger correlations with multiecho MRS FFs than with the dual-echo method (R = 0.86; P ≤ 0.011). The FFs estimated with multiinterference method showed the closest agreement with multiecho MRS FFs (the 95% limit-of-agreement, -0.2 ± 1.1). T2*- or T2-correction methods are effective in correcting the confounding effects of iron, enabling an accurate fat quantification throughout a wide range of iron concentrations. Spectral modeling of fat may further improve the accuracy of CS-MRI in fat quantification. Copyright © 2011 Wiley-Liss, Inc.
López, Laura B; Baroni, Andrea V; Rodríguez, Viviana G; Greco, Carola B; de Costa, Sara Macías; de Ferrer, Patricia Ronayne; Rodríguez de Pece, Silvia
2005-06-01
A methodology for the quantification of vitamin A in human milk was developed and validated. Vitamin A levels were assessed in 223 samples corresponding to the 5th, 6th and 7th postpartum months, obtained in the province of Santiago del Estero, Argentina. The samples (500 microL) were saponified with potassium hydroxide/ethanol, extracted with hexane, evaporated to dryness and reconstituted with methanol. A column RP-C18, a mobile phase methanol/water (91:9 v/v) and a fluorescence detector (lambda excitation 330 nm and lambda emition 470 nm) were used for the separation and quantification of vitamin A. The analytical parameters of linearity (r2: 0.9995), detection (0.010 microg/mL) and quantification (0.025 microg/mL) limits, precision of the method (relative standard deviation, RSD = 9.0% within a day and RSD = 8.9% among days) and accuracy (recovery = 83.8%) demonstrate that the developed method allows the quantification of vitamin A in an efficient way. The mean values + standard deviation (SD) obtained for the analyzed samples were 0.60 +/- 0.32; 0.65 +/- 0.33 and 0.61 +/- 0.26 microg/ mL for the 5th, 6th and 7th postpartum months, respectively. There were no significant differences among the three months studied and the values found were similar to those in the literature. Considering the whole population under study, 19.3% showed vitamin A levels less than 0.40 microg/mL, which represents a risk to the children in this group since at least 0.50 microg/mL are necessary to meet the infant daily needs.
Effects of bioirrigation of non-biting midges (Diptera: Chironomidae) on lake sediment respiration
Baranov, Viktor; Lewandowski, Jörg; Romeijn, Paul; Singer, Gabriel; Krause, Stefan
2016-01-01
Bioirrigation or the transport of fluids into the sediment matrix due to the activities of organisms such as bloodworms (larvae of Diptera, Chironomidae), has substantial impacts on sediment respiration in lakes. However, previous quantifications of bioirrigation impacts of Chironomidae have been limited by technical challenges such as the difficulty to separate faunal and bacterial respiration. This paper describes a novel method based on the bioreactive tracer resazurin for measuring respiration in-situ in non-sealed systems with constant oxygen supply. Applying this new method in microcosm experiments revealed that bioirrigation enhanced sediment respiration by up to 2.5 times. The new method is yielding lower oxygen consumption than previously reported, as it is only sensitive to aerobic heterotrophous respiration and not to other processes causing oxygen decrease. Hence it decouples the quantification of respiration of animals and inorganic oxygen consumption from microbe respiration in sediment. PMID:27256514
Effects of bioirrigation of non-biting midges (Diptera: Chironomidae) on lake sediment respiration.
Baranov, Viktor; Lewandowski, Jörg; Romeijn, Paul; Singer, Gabriel; Krause, Stefan
2016-06-03
Bioirrigation or the transport of fluids into the sediment matrix due to the activities of organisms such as bloodworms (larvae of Diptera, Chironomidae), has substantial impacts on sediment respiration in lakes. However, previous quantifications of bioirrigation impacts of Chironomidae have been limited by technical challenges such as the difficulty to separate faunal and bacterial respiration. This paper describes a novel method based on the bioreactive tracer resazurin for measuring respiration in-situ in non-sealed systems with constant oxygen supply. Applying this new method in microcosm experiments revealed that bioirrigation enhanced sediment respiration by up to 2.5 times. The new method is yielding lower oxygen consumption than previously reported, as it is only sensitive to aerobic heterotrophous respiration and not to other processes causing oxygen decrease. Hence it decouples the quantification of respiration of animals and inorganic oxygen consumption from microbe respiration in sediment.
Effects of bioirrigation of non-biting midges (Diptera: Chironomidae) on lake sediment respiration
NASA Astrophysics Data System (ADS)
Baranov, Viktor; Lewandowski, Jörg; Romeijn, Paul; Singer, Gabriel; Krause, Stefan
2016-06-01
Bioirrigation or the transport of fluids into the sediment matrix due to the activities of organisms such as bloodworms (larvae of Diptera, Chironomidae), has substantial impacts on sediment respiration in lakes. However, previous quantifications of bioirrigation impacts of Chironomidae have been limited by technical challenges such as the difficulty to separate faunal and bacterial respiration. This paper describes a novel method based on the bioreactive tracer resazurin for measuring respiration in-situ in non-sealed systems with constant oxygen supply. Applying this new method in microcosm experiments revealed that bioirrigation enhanced sediment respiration by up to 2.5 times. The new method is yielding lower oxygen consumption than previously reported, as it is only sensitive to aerobic heterotrophous respiration and not to other processes causing oxygen decrease. Hence it decouples the quantification of respiration of animals and inorganic oxygen consumption from microbe respiration in sediment.
Leclercq, L; Laurent, C; De Pauw, E
1997-05-15
A method was developed for the analysis of 7-(2-hydroxyethyl)guanine (7HEG), the major DNA adduct formed after exposure to ethylene oxide (EO). The method is based on DNA neutral thermal hydrolysis, adduct micro-concentration, and final characterization and quantification by HPLC coupled to single-ion monitoring electrospray mass spectrometry (HPLC/SIR-ESMS). The method was found to be selective, sensitive, and easy to handle with no need for enzymatic digestion or previous sample derivatization. Detection limit was found to be close to 1 fmol of adduct injected (10(-10) M), thus allowing the detection of approximately three modified bases on 10(8) intact nucleotides in blood sample analysis. Quantification results are shown for 7HEG after calf thymus DNA and blood exposure to various doses of EO, in both cases obtaining clear dose-response relationships.
Stillhart, Cordula; Kuentz, Martin
2012-02-05
Self-emulsifying drug delivery systems (SEDDS) are complex mixtures in which drug quantification can become a challenging task. Thus, a general need exists for novel analytical methods and a particular interest lies in techniques with the potential for process monitoring. This article compares Raman spectroscopy with high-resolution ultrasonic resonator technology (URT) for drug quantification in SEDDS. The model drugs fenofibrate, indomethacin, and probucol were quantitatively assayed in different self-emulsifying formulations. We measured ultrasound velocity and attenuation in the bulk formulation containing drug at different concentrations. The formulations were also studied by Raman spectroscopy. We used both, an in-line immersion probe for the bulk formulation and a multi-fiber sensor for measuring through hard-gelatin capsules that were filled with SEDDS. Each method was assessed by calculating the relative standard error of prediction (RSEP) as well as the limit of quantification (LOQ) and the mean recovery. Raman spectroscopy led to excellent calibration models for the bulk formulation as well as the capsules. The RSEP depended on the SEDDS type with values of 1.5-3.8%, while LOQ was between 0.04 and 0.35% (w/w) for drug quantification in the bulk. Similarly, the analysis of the capsules led to RSEP of 1.9-6.5% and LOQ of 0.01-0.41% (w/w). On the other hand, ultrasound attenuation resulted in RSEP of 2.3-4.4% and LOQ of 0.1-0.6% (w/w). Moreover, ultrasound velocity provided an interesting analytical response in cases where the drug strongly affected the density or compressibility of the SEDDS. We conclude that ultrasonic resonator technology and Raman spectroscopy constitute suitable methods for drug quantification in SEDDS, which is promising for their use as process analytical technologies. Copyright © 2011 Elsevier B.V. All rights reserved.
Shi, Yan; Xiong, Jing; Sun, Dongmei; Liu, Wei; Wei, Feng; Ma, Shuangcheng; Lin, Ruichao
2015-08-01
An accurate and sensitive high-performance liquid chromatography method coupled with ultralviolet detection and precolumn derivatization was developed for the simultaneous quantification of the major bile acids in Artificial Calculus bovis, including cholic acid, hyodeoxycholic acid, chenodeoxycholic acid, and deoxycholic acid. The extraction, derivatization, chromatographic separation, and detection parameters were fully optimized. The samples were extracted with methanol by ultrasonic extraction. Then, 2-bromine-4'-nitroacetophenone and 18-crown ether-6 were used for derivatization. The chromatographic separation was performed on an Agilent SB-C18 column (250 × 4.6 mm id, 5 μm) at a column temperature of 30°C and liquid flow rate of 1.0 mL/min using water and methanol as the mobile phase with a gradient elution. The detection wavelength was 263 nm. The method was extensively validated by evaluating the linearity (r(2) ≥ 0.9980), recovery (94.24-98.91%), limits of detection (0.25-0.31 ng) and limits of quantification (0.83-1.02 ng). Seventeen samples were analyzed using the developed and validated method. Then, the amounts of bile acids were analyzed by hierarchical agglomerative clustering analysis and principal component analysis. The results of the chemometric analysis showed that the contents of these compounds reflect the intrinsic quality of artificial Calculus bovis, and two compounds (hyodeoxycholic acid and chenodeoxycholic acid) were the most important markers for quality evaluating. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Troise, Antonio Dario; Fiore, Alberto; Roviello, Giovanni; Monti, Simona Maria; Fogliano, Vincenzo
2015-01-01
The formation of the Amadori products (APs) is the first key step of Maillard reaction. Only few papers have dealt with simultaneous quantitation of amino acids and corresponding APs (1-amino-1-deoxy-2-ketose). Chromatographic separation of APs is affected by several drawbacks mainly related to their poor retention in conventional reversed phase separation. In this paper, a method for the simultaneous quantification of amino acids and their respective APs was developed combining high-resolution mass spectrometry with ion-pairing liquid chromatography. The limit of detection was 0.1 ng/mL for tryptophan, valine and arginine, while the limit of quantification ranged from 2 to 5 ng/mL according to the specific sensitivity of each analyte. The relative standard deviation % was lower than 10 % and the coefficient of correlation was higher than 0.99 for each calibration curve. The method was applied to milk, milk-based products, raw and processed tomato. Among the analyzed products, the most abundant amino acid was glutamic acid (16,646.89 ± 1,385.40 µg/g) and the most abundant AP was fructosyl-arginine in tomato puree (774.82 ± 10.01 µg/g). The easiness of sample preparation coupled to the analytical performances of the proposed method introduced the possibility to use the pattern of free amino acids and corresponding APs in the evaluation of the quality of raw food as well as the extent of thermal treatments in different food products.
Wicker, A Paige; Carlton, Doug D; Tanaka, Kenichiro; Nishimura, Masayuki; Chen, Vivian; Ogura, Tairo; Hedgepeth, William; Schug, Kevin A
2018-06-01
On-line supercritical fluid extraction - supercritical fluid chromatography - mass spectrometry (SFE-SFC-MS) has been applied for the determination of polycyclic aromatic hydrocarbons (PAHs) in soil. The purpose of this study was to develop and validate the first on-line SFE-SFC-MS method for the quantification of PAHs in various types of soil. By coupling the sample extraction on-line with chromatography and detection, sample preparation is minimized, diminishing sample loss and contamination, and significantly decreasing the required extraction time. Parameters for on-line extraction coupled to chromatographic analysis were optimized. The method was validated for concentrations of 10-1500 ng of PAHs per gram of soil in Certified Reference Material (CRM) sediment, clay, and sand with R 2 ≥ 0.99. Limits of detection (LOD) were found in the range of 0.001-5 ng/g, and limits of quantification (LOQ) in the range of 5-15 ng/g. The method developed in this study can be effectively applied to the study of PAHs in the environment, and may lay the foundation for further applications of on-line SFE-SFC-MS. Copyright © 2018 Elsevier B.V. All rights reserved.
Rupert, Déborah L M; Claudio, Virginia; Lässer, Cecilia; Bally, Marta
2017-01-01
Our body fluids contain a multitude of cell-derived vesicles, secreted by most cell types, commonly referred to as extracellular vesicles. They have attracted considerable attention for their function as intercellular communication vehicles in a broad range of physiological processes and pathological conditions. Extracellular vesicles and especially the smallest type, exosomes, have also generated a lot of excitement in view of their potential as disease biomarkers or as carriers for drug delivery. In this context, state-of-the-art techniques capable of comprehensively characterizing vesicles in biological fluids are urgently needed. This review presents the arsenal of techniques available for quantification and characterization of physical properties of extracellular vesicles, summarizes their working principles, discusses their advantages and limitations and further illustrates their implementation in extracellular vesicle research. The small size and physicochemical heterogeneity of extracellular vesicles make their physical characterization and quantification an extremely challenging task. Currently, structure, size, buoyant density, optical properties and zeta potential have most commonly been studied. The concentration of vesicles in suspension can be expressed in terms of biomolecular or particle content depending on the method at hand. In addition, common quantification methods may either provide a direct quantitative measurement of vesicle concentration or solely allow for relative comparison between samples. The combination of complementary methods capable of detecting, characterizing and quantifying extracellular vesicles at a single particle level promises to provide new exciting insights into their modes of action and to reveal the existence of vesicle subpopulations fulfilling key biological tasks. Copyright © 2016 Elsevier B.V. All rights reserved.
Computer-aided assessment of regional abdominal fat with food residue removal in CT.
Makrogiannis, Sokratis; Caturegli, Giorgio; Davatzikos, Christos; Ferrucci, Luigi
2013-11-01
Separate quantification of abdominal subcutaneous and visceral fat regions is essential to understand the role of regional adiposity as risk factor in epidemiological studies. Fat quantification is often based on computed tomography (CT) because fat density is distinct from other tissue densities in the abdomen. However, the presence of intestinal food residues with densities similar to fat may reduce fat quantification accuracy. We introduce an abdominal fat quantification method in CT with interest in food residue removal. Total fat was identified in the feature space of Hounsfield units and divided into subcutaneous and visceral components using model-based segmentation. Regions of food residues were identified and removed from visceral fat using a machine learning method integrating intensity, texture, and spatial information. Cost-weighting and bagging techniques were investigated to address class imbalance. We validated our automated food residue removal technique against semimanual quantifications. Our feature selection experiments indicated that joint intensity and texture features produce the highest classification accuracy at 95%. We explored generalization capability using k-fold cross-validation and receiver operating characteristic (ROC) analysis with variable k. Losses in accuracy and area under ROC curve between maximum and minimum k were limited to 0.1% and 0.3%. We validated tissue segmentation against reference semimanual delineations. The Dice similarity scores were as high as 93.1 for subcutaneous fat and 85.6 for visceral fat. Computer-aided regional abdominal fat quantification is a reliable computational tool for large-scale epidemiological studies. Our proposed intestinal food residue reduction scheme is an original contribution of this work. Validation experiments indicate very good accuracy and generalization capability. Published by Elsevier Inc.
Idilman, Ilkay S; Keskin, Onur; Celik, Azim; Savas, Berna; Elhan, Atilla Halil; Idilman, Ramazan; Karcaaltincaba, Musturay
2016-03-01
Many imaging methods have been defined for quantification of hepatic steatosis in non-alcoholic fatty liver disease (NAFLD). However, studies comparing the efficiency of magnetic resonance imaging-proton density fat fraction (MRI-PDFF), magnetic resonance spectroscopy (MRS), and liver histology for quantification of liver fat content are limited. To compare the efficiency of MRI-PDFF and MRS in the quantification of liver fat content in individuals with NAFLD. A total of 19 NAFLD patients underwent MRI-PDFF, MRS, and liver biopsy for quantification of liver fat content. The MR examinations were performed on a 1.5 HDx MRI system. The MRI protocol included T1-independent volumetric multi-echo gradient-echo imaging with T2* correction and spectral fat modeling and MRS with STEAM technique. A close correlation was observed between liver MRI-PDFF- and histology- determined steatosis (r = 0.743, P < 0.001) and between liver MRS- and histology-determined steatosis (r = 0.712, P < 0.001), with no superiority between them (ƶ = 0.19, P = 0.849). For quantification of hepatic steatosis, a high correlation was observed between the two MRI methods (r = 0.986, P < 0.001). MRI-PDFF and MRS accurately differentiated moderate/severe steatosis from mild/no hepatic steatosis (P = 0.007 and 0.013, respectively), with no superiority between them (AUCMRI-PDFF = 0.881 ± 0.0856 versus AUCMRS = 0.857 ± 0.0924, P = 0.461). Both MRI-PDFF and MRS can be used for accurate quantification of hepatic steatosis. © The Foundation Acta Radiologica 2015.
Johänning, Janina; Heinkele, Georg; Precht, Jana C; Brauch, Hiltrud; Eichelbaum, Michel; Schwab, Matthias; Schroth, Werner; Mürdter, Thomas E
2015-09-01
Tamoxifen is a mainstay in the treatment of estrogen receptor-positive breast cancer and is metabolized to more than 30 different compounds. Little is known about in vivo concentrations of estrogenic metabolites E-metabolite E, Z-metabolite E, and bisphenol and their relevance for tamoxifen efficacy. Therefore, we developed a highly sensitive HPLC-ESI-MS/MS quantification method for tamoxifen metabolites bisphenol, E-metabolite E, and Z-metabolite E as well as for the sex steroid hormones estradiol, estrone, testosterone, androstenedione, and progesterone. Plasma samples were subjected to protein precipitation followed by solid phase extraction. Upon derivatization with 3-[(N-succinimide-1-yl)oxycarbonyl]-1-methylpyridinium iodide, all analytes were separated on a sub-2-μm column with a gradient of acetonitrile in water with 0.1 % of formic acid. Analytes were detected on a triple-quadrupole mass spectrometer with positive electrospray ionization in the multiple reaction monitoring mode. Our method demonstrated high sensitivity, accuracy, and precision. The lower limits of quantification were 12, 8, and 25 pM for bisphenol, E-metabolite E, and Z-metabolite E, respectively, and 4 pM for estradiol and estrogen, 50 pM for testosterone and androstenedione, and 25 pM for progesterone. The method was applied to plasma samples of postmenopausal patients taken at baseline and under tamoxifen therapy. Graphical Abstract Sample preparation and derivatization for highly sensitive quantification of estrogenic tamoxifen metabolites and steroid hormones by HPLC-MS/MS.
NASA Astrophysics Data System (ADS)
Hu, Yong; Wu, Hai-Long; Yin, Xiao-Li; Gu, Hui-Wen; Xiao, Rong; Wang, Li; Fang, Huan; Yu, Ru-Qin
2017-03-01
A rapid interference-free spectrofluorometric method combined with the excitation-emission matrix fluorescence and the second-order calibration methods based on the alternating penalty trilinear decomposition (APTLD) and the self-weighted alternating trilinear decomposition (SWATLD) algorithms, was proposed for the simultaneous determination of nephrotoxic aristolochic acid I (AA-I) and aristololactam I (AL-I) in five Chinese herbal medicines. The method was based on a chemical derivatization that converts the non-fluorescent AA-I to high-fluorescent AL-I, achieving a high sensitive and simultaneous quantification of the analytes. The variables of the derivatization reaction that conducted by using zinc powder in acetose methanol aqueous solution, were studied and optimized for best quantification results of AA-I and AL-I. The satisfactory results of AA-I and AL-I for the spiked recovery assay were achieved with average recoveries in the range of 100.4-103.8% and RMSEPs < 0.78 ng mL- 1, which validate the accuracy and reliability of the proposed method. The contents of AA-I and AL-I in five herbal medicines obtained from the proposed method were also in good accordance with those of the validated LC-MS/MS method. In light of high sensitive fluorescence detection, the limits of detection (LODs) of AA-I and AL-I for the proposed method compare favorably with that of the LC-MS/MS method, with the LODs < 0.35 and 0.29 ng mL- 1, respectively. The proposed strategy based on the APTLD and SWATLD algorithms by virtue of the "second-order advantage", can be considered as an attractive and green alternative for the quantification of AA-I and AL-I in complex herbal medicine matrices without any prior separations and clear-up processes.
Arroyo-Manzanares, Natalia; Huertas-Pérez, José F; Gámiz-Gracia, Laura; García-Campaña, Ana M
2013-10-15
A sensitive, simple and rapid method for the determination of fourteen mycotoxins in nuts and seeds (including almonds, peanuts, sunflower seeds, pumpkin seeds, walnuts, macadamia nuts, pistachios, hazelnuts and pine nuts) has been developed using ultra-high performance liquid chromatography coupled with tandem mass spectrometry (UHPLC-MS/MS). The sample treatment comprises a first step based on QuEChERS procedure for the determination of fumonisin B1, fumonisin B2, deoxynivalenol, fusarenon-X, T-2 and HT-2 toxin, citrinin, sterigmatocystin, zearalenone and ochratoxin A. A subsequent clean-up step based on the dispersive liquid-liquid microextraction (DLLME) was necessary for the determination of aflatoxins (B1, B2, G1 and G2), since their determination was not possible applying only the QuEChERS-based extraction. The method was validated for peanuts as representative matrix and was subsequently evaluated for the other eight matrices. Quantification limits obtained for aflatoxins, the unique mycotoxins legislated on these matrices, were lower than the maximum levels allowed by the current legislation, while quantification limits obtained for the other mycotoxins were lower than the limits usually permitted by the legislation in other food matrices. Precision of the method was always lower than 11%, and recoveries ranged between 60.7% and 104.3%. © 2013 Elsevier B.V. All rights reserved.
Vaudano, Enrico; Costantini, Antonella; Garcia-Moruno, Emilia
2016-10-03
The availability of genetically modified (GM) yeasts for winemaking and, in particular, transgenic strains based on the integration of genetic constructs deriving from other organisms into the genome of Saccharomyces cerevisiae, has been a reality for several years. Despite this, their use is only authorized in a few countries and limited to two strains: ML01, able to convert malic acid into lactic acid during alcoholic fermentation, and ECMo01 suitable for reducing the risk of carbamate production. In this work we propose a quali-quantitative culture-independent method for the detection of GM yeast ML01 in commercial preparations of ADY (Active Dry Yeast) consisting of efficient extraction of DNA and qPCR (quantitative PCR) analysis based on event-specific assay targeting MLC (malolactic cassette), and a taxon-specific S. cerevisiae assay detecting the MRP2 gene. The ADY DNA extraction methodology has been shown to provide good purity DNA suitable for subsequent qPCR. The MLC and MRP2 qPCR assay showed characteristics of specificity, dynamic range, limit of quantification (LOQ) limit of detection (LOD), precision and trueness, which were fully compliant with international reference guidelines. The method has been shown to reliably detect 0.005% (mass/mass) of GM ML01 S. cerevisiae in commercial preparations of ADY. Copyright © 2016 Elsevier B.V. All rights reserved.
Nicolucci, Carla; Errico, Sonia; Federico, Alessandro; Dallio, Marcello; Loguercio, Carmelina; Diano, Nadia
2017-06-05
A selective and highly sensitive analytical methodology for determination of Bisphenol A in human plasma was developed and validated. The method was based on selective liquid/solid extraction, combined with liquid chromatography-electrospray ionization tandem mass spectrometry in the multiple reaction monitoring mode and negative ionization. The linearity of the detector response was verified in human plasma over the concentration range 0.100-200ngmL -1 . The detection limit was 0.03ngmL -1 and the quantification limit was 0.100ngmL -1 . The analytical features of the proposed in-house validated method were satisfactory: precision was <10% and recoveries were around 84-104%. The matrix effect was studied and compensated using deuterated labeled standard. The applicability of the proposed method was demonstrated analyzing human plasma samples from individuals affected by non-alcoholic fatty liver disease. Bisphenol A was detected above the detection limit in all samples. The data show a persistence of unconjugated Bisphenol A levels in plasma and indicate a chronic Bisphenol A exposure of the target organ, suggesting an association between liver health status and Bisphenol A exposure. The results from our study are valuable for further investigation with large sample size and longitudinal study designs, necessary to confirm the observed association. Copyright © 2017 Elsevier B.V. All rights reserved.
Finnegan, Christopher; Ryan, David; Enright, Anne-Marie; Garcia-Cabellos, Guiomar
2018-03-10
Tributyltin (TBT) is one of the most toxic anthropogenic compounds introduced into the marine environment. Despite its global ban in 2008, TBT is still a problem of great concern due to its high affinity for particulate matter, providing a direct and potentially persistent route of entry into benthic sediments. Bioremediation strategies may constitute an alternative approach to conventional physicochemical methods, benefiting from the microorganism's potential to metabolize anthropogenic compounds. In this work, a simple, precise and accurate static headspace gas chromatography method was developed to investigate the ability of TBT degrading microbes in sedimentary microcosms over a period of 120 days. The proposed method was validated for linearity, repeatability, accuracy, specificity, limit of detection and limit of quantification. The method was subsequently successfully applied for the detection and quantification of TBT and degradation compounds in sediment samples on day 0, 30, 60, 90 and 120 of the experiment employing the principles of green chemistry. On day 120 the concentration of TBT remaining in the microcosms ranged between 91.91 ng/g wet wt for the least effective microbial inoculant to 52.73 ng/g wet wt for the most effective microbial inoculant from a starting concentration of 100 ng/g wet wt.
Rapid Quantitative Detection of Lactobacillus sakei in Meat and Fermented Sausages by Real-Time PCR
Martín, Belén; Jofré, Anna; Garriga, Margarita; Pla, Maria; Aymerich, Teresa
2006-01-01
A quick and simple method for quantitative detection of Lactobacillus sakei in fermented sausages was successfully developed. It is based on Chelex-100-based DNA purification and real-time PCR enumeration using a TaqMan fluorescence probe. Primers and probes were designed in the L. sakei 16S-23S rRNA intergenic transcribed spacer region, and the assay was evaluated using L. sakei genomic DNA and an artificially inoculated sausage model. The detection limit of this technique was approximately 3 cells per reaction mixture using both purified DNA and the inoculated sausage model. The quantification limit was established at 30 cells per reaction mixture in both models. The assay was then applied to enumerate L. sakei in real samples, and the results were compared to the MRS agar count method followed by confirmation of the percentage of L. sakei colonies. The results obtained by real-time PCR were not statistically significantly different than those obtained by plate count on MRS agar (P > 0.05), showing a satisfactory agreement between both methods. Therefore, the real-time PCR assay developed can be considered a promising rapid alternative method for the quantification of L. sakei and evaluation of the implantation of starter strains of L. sakei in fermented sausages. PMID:16957227
Liu, Huihui; Han, Dianfeng; Huang, Hui; Xu, Yingjiang; Gong, Xianghong
2018-01-01
This study developed an ultraperformance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method for the detection of three major metabolites of mequindox, including 3-methyl-quinoxaline-2-carboxylic acid, 1-desoxymequindox, and 1,4-bisdesoxymequindox (MQCA, 1-DMEQ, and BDMEQ), in holothurian. Target analytes were simplified with ultrasound-assisted acidolysis extracted without complicated enzymolysis steps. After that, each sample was centrifuged and purified by an Oasis MAX cartridge. Then, the processed samples were separated and monitored by UPLC-MS/MS. This developed method has been validated according to FDA criteria. At fortified levels of 2, 10, and 20 μg/kg, recoveries ranged from 82.5% to 93.5% with the intraday RSD less than 7.27% and interday RSD less than 11.8%. The limit of detection (LOD) of all the three metabolites ranged from 0.21 to 0.48 μg/kg, while the limit of quantification (LOQ) ranged from 0.79 to 1.59 μg/kg. On application to commercial samples, 14 of 20 samples were detected positive for the three target analytes, with positive rate at 70 percentage. The result indicated that this method was specific, sensitive, and suitable for the quantification and conformation of the three major metabolites of MEQ in holothurian. PMID:29805832
Liu, Huihui; Ren, Chuanbo; Han, Dianfeng; Huang, Hui; Zou, Rongjie; Zhang, Huawei; Xu, Yingjiang; Gong, Xianghong; Zhang, Xiuzhen; Li, Yanshen
2018-01-01
This study developed an ultraperformance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method for the detection of three major metabolites of mequindox, including 3-methyl-quinoxaline-2-carboxylic acid, 1-desoxymequindox, and 1,4-bisdesoxymequindox (MQCA, 1-DMEQ, and BDMEQ), in holothurian. Target analytes were simplified with ultrasound-assisted acidolysis extracted without complicated enzymolysis steps. After that, each sample was centrifuged and purified by an Oasis MAX cartridge. Then, the processed samples were separated and monitored by UPLC-MS/MS. This developed method has been validated according to FDA criteria. At fortified levels of 2, 10, and 20 μ g/kg, recoveries ranged from 82.5% to 93.5% with the intraday RSD less than 7.27% and interday RSD less than 11.8%. The limit of detection (LOD) of all the three metabolites ranged from 0.21 to 0.48 μ g/kg, while the limit of quantification (LOQ) ranged from 0.79 to 1.59 μ g/kg. On application to commercial samples, 14 of 20 samples were detected positive for the three target analytes, with positive rate at 70 percentage. The result indicated that this method was specific, sensitive, and suitable for the quantification and conformation of the three major metabolites of MEQ in holothurian.
Rapid quantitative detection of Lactobacillus sakei in meat and fermented sausages by real-time PCR.
Martín, Belén; Jofré, Anna; Garriga, Margarita; Pla, Maria; Aymerich, Teresa
2006-09-01
A quick and simple method for quantitative detection of Lactobacillus sakei in fermented sausages was successfully developed. It is based on Chelex-100-based DNA purification and real-time PCR enumeration using a TaqMan fluorescence probe. Primers and probes were designed in the L. sakei 16S-23S rRNA intergenic transcribed spacer region, and the assay was evaluated using L. sakei genomic DNA and an artificially inoculated sausage model. The detection limit of this technique was approximately 3 cells per reaction mixture using both purified DNA and the inoculated sausage model. The quantification limit was established at 30 cells per reaction mixture in both models. The assay was then applied to enumerate L. sakei in real samples, and the results were compared to the MRS agar count method followed by confirmation of the percentage of L. sakei colonies. The results obtained by real-time PCR were not statistically significantly different than those obtained by plate count on MRS agar (P > 0.05), showing a satisfactory agreement between both methods. Therefore, the real-time PCR assay developed can be considered a promising rapid alternative method for the quantification of L. sakei and evaluation of the implantation of starter strains of L. sakei in fermented sausages.
Viegas, O; Novo, P; Pinho, O; Ferreira, I M P L V O
2012-01-15
A method for analysis of 15 PAHs in charcoal-grilled meat/fish was established by high performance liquid chromatography and fluorescence detection. Gradient elution was performed with methanol/water/ethyl acetate. Maxima excitation and emission wavelengths were selected for each PAH. Retention times were very stable with coefficients of variation below 0.24% within analytical day and below 0.60% across analytical days. Two different methods of cleanup and pre-concentration steps were compared. Solvent extraction assisted by sonication carried out with n-hexane on 2g of lyophilized meat or 1g of lyophilized fish allowed to obtain high sensitivity, reproducibility and better extraction efficiency. Limits of quantification (LOQs, s/n=10) were lower than 0.01ng/g of meat wet weight and lower than 0.02ng/g of fish wet weight for all PAHs (except for Na, Fl and IP that were lower than 0.1ng/g). Two different quantification methods were compared. Standard addition method compensated PAHs losses due to incomplete extraction and it is recommended for analyses of grilled meat and fish samples that usually contain very low amounts of the eight high molecular weight PAHs (BaA, Ch, BbF, BkF, BaP, IP, BgP, DhA). Copyright © 2011 Elsevier B.V. All rights reserved.
Quantification of febuxostat polymorphs using powder X-ray diffraction technique.
Qiu, Jing-bo; Li, Gang; Sheng, Yue; Zhu, Mu-rong
2015-03-25
Febuxostat is a pharmaceutical compound with more than 20 polymorphs of which form A is most widely used and usually exists in a mixed polymorphic form with form G. In the present study, a quantification method for polymorphic form A and form G of febuxostat (FEB) has been developed using powder X-ray diffraction (PXRD). Prior to development of a quantification method, pure polymorphic form A and form G are characterized. A continuous scan with a scan rate of 3° min(-1) over an angular range of 3-40° 2θ is applied for the construction of the calibration curve using the characteristic peaks of form A at 12.78° 2θ (I/I0100%) and form G at 11.72° 2θ (I/I0100%). The linear regression analysis data for the calibration plots shows good linear relationship with R(2)=0.9985 with respect to peak area in the concentration range 10-60 wt.%. The method is validated for precision, recovery and ruggedness. The limits of detection and quantitation are 1.5% and 4.6%, respectively. The obtained results prove that the method is repeatable, sensitive and accurate. The proposed developed PXRD method can be applied for the quantitative analysis of mixtures of febuxostat polymorphs (forms A and G). Copyright © 2015 Elsevier B.V. All rights reserved.
Song, Zhiling; Hashi, Yuki; Sun, Hongyang; Liang, Yi; Lan, Yuexiang; Wang, Hong; Chen, Shizhong
2013-12-01
The flowers of Trollius species, named Jin Lianhua in Chinese, are widely used traditional Chinese herbs with vital biological activity that has been used for several decades in China to treat upper respiratory infections, pharyngitis, tonsillitis, and bronchitis. We developed a rapid and reliable method for simultaneous quantitative analysis of 19 flavonoids in trollflowers by using high-performance liquid chromatography (HPLC). Chromatography was performed on Inertsil ODS-3 C18 column, with gradient elution methanol-acetonitrile-water with 0.02% (v/v) formic acid. Content determination was used to evaluate the quality of commercial trollflowers from different regions in China, while three Trollius species (Trollius chinensis Bunge, Trollius ledebouri Reichb, Trollius buddae Schipcz) were explicitly distinguished by using hierarchical clustering analysis. The linearity, precision, accuracy, limit of detection, and limit of quantification were validated for the quantification method, which proved sensitive, accurate and reproducible indicating that the proposed approach was applicable for the routine analysis and quality control of trollflowers. © 2013.
Pralatnet, Sasithorn; Poapolathep, Saranya; Giorgi, Mario; Imsilp, Kanjana; Kumagai, Susumu; Poapolathep, Amnart
2016-07-01
One hundred wheat product samples (50 instant noodle samples and 50 bread samples) were collected from supermarkets in Bangkok, Thailand. Deoxynivalenol (DON) and aflatoxin B1 (AFB1) contamination in these products was analyzed using a validated liquid chromatography-tandem mass spectrometry method. The limit of quantification values of DON and AFB1 in the instant noodles and bread were 2 and 1 ng g(-1), respectively. The survey found that DON was quantifiable in 40% of collected samples, in 2% of noodles (0.089 μg g(-1)), and in 78% of breads (0.004 to 0.331 μg g(-1)). AFB1 was below the limit of quantification of the method in all of the tested samples. The results suggest that the risk of DON exposure via noodles and breads is very low in urban areas of Thailand. No risk can be attributable to AFB1 exposure in the same food matrices, but further studies with a larger sample size are needed to confirm these data.
NASA Technical Reports Server (NTRS)
Levine, Lanfang H.; Garland, Jay L.; Johnson, Jodie V.
2002-01-01
An amphoteric (cocamidopropylbetaine, CAPB) and a nonionic (alcohol polyethoxylate, AE) surfactant were characterized by electrospray ionization quadrupole ion trap mass spectrometry (ESI-MS) as to their homologue distribution and ionization/fragmentation chemistry. Quantitative methods involving reversed-phase gradient HPLC and (+)ESI-MSn were developed to directly determine these surfactants in hydroponic plant growth medium that received simulated graywater. The predominant homologues, 12 C alkyl CAPB and 9 EO AE, were monitored to represent the total amount of the respective surfactants. The methods demonstrated dynamic linear ranges of 0.5-250 ng (r2 > 0.996) for CAPB and 8-560 ng (r2 > 0.998) for AE homologue mixture, corresponding to minimum quantification limits of 25 ppb CAPB and 0.4 ppm AE with 20-microL injections. This translated into an even lower limit for individual components due to the polydispersive nature of the surfactants. The procedure was successfully employed for the assessment of CAPB and AE biodegradation in a hydroponic plant growth system used as a graywater bioreactor.
Addressing matrix effects in ligand-binding assays through the use of new reagents and technology.
Chilewski, Shannon D; Mora, Johanna R; Gleason, Carol; DeSilva, Binodh
2014-04-01
Ligand-binding assays (LBAs) used in the quantification of biotherapeutics for pharmacokinetic determinations rely on interactions between reagents (antibodies or target molecule) and the biotherapeutic. Most LBAs do not employ an analyte extraction procedure and are susceptible to matrix interference. Here, we present a case study on the development of a LBA for the quantification of a PEGylated domain antibody where matrix interference was observed. The assay used to support the single ascending dose study was a plate-based electrochemiluminescent assay with a lower limit of quantification of 80 ng/mL. To meet sensitivity requirements of future studies, new reagents and the Gyrolab™ Workstation were evaluated. Assay sensitivity improved nearly threefold in the final method utilizing new antibody reagents, a buffer containing blockers to human anti-animal antibodies, and the Gyrolab Workstation. Experimental data indicate that all factors changed played a role in overcoming matrix effects.
Microvolume protein concentration determination using the NanoDrop 2000c spectrophotometer.
Desjardins, Philippe; Hansen, Joel B; Allen, Michael
2009-11-04
Traditional spectrophotometry requires placing samples into cuvettes or capillaries. This is often impractical due to the limited sample volumes often used for protein analysis. The Thermo Scientific NanoDrop 2000c Spectrophotometer solves this issue with an innovative sample retention system that holds microvolume samples between two measurement surfaces using the surface tension properties of liquids, enabling the quantification of samples in volumes as low as 0.5-2 microL. The elimination of cuvettes or capillaries allows real time changes in path length, which reduces the measurement time while greatly increasing the dynamic range of protein concentrations that can be measured. The need for dilutions is also eliminated, and preparations for sample quantification are relatively easy as the measurement surfaces can be simply wiped with laboratory wipe. This video article presents modifications to traditional protein concentration determination methods for quantification of microvolume amounts of protein using A280 absorbance readings or the BCA colorimetric assay.
Covaci, Eniko; Senila, Marin; Ponta, Michaela; Darvasi, Eugen; Petreus, Dorin; Frentiu, Maria; Frentiu, Tiberiu
2017-08-01
A non-chromatographic method based on double liquid-liquid extraction and measurements by UV photochemical vapor generation capacitively coupled plasma microtorch optical emission spectrometry was developed and characterized for methylmercury determination in seafood. Samples were prepared following the procedure recommended in JRC Technical Report of European Commission formerly proposed for the determination of methylmercury in seafood by thermal decomposition atomic absorption spectrometry, namely confinement of Hg species in 47% HBr solution, extraction of CH 3 Hg + in toluene and back-extraction in 1% l-cysteine aqueous solution. Mercury cold vapor was generated by flow injection UV photo-reduction from CH 3 Hg + in 0.6molL -1 HCOOH, while quantification was performed against external Hg 2+ aqueous standards and measuring Hg 253.652nm emission using a low power/Ar consumption plasma microtorch (15W, 100mLmin -1 ) and a low resolution microspectrometer (Ocean Optics). The figures of merit and analytical capability were assessed by analyzing certified reference materials and test samples of fish fillet and discussed in relation with requirements for Hg determination in seafood in European legislation (Decisions 2007/333/EC and 2002/657/EC) as well as compared to performances achieved in thermal decomposition atomic absorption spectrometry. The limit of detection and quantification of 2µgkg -1 and 6µgkg -1 respectively, precision of 2.7-9.4% and accuracy of 99±8% of the proposed method for the determination of CH 3 Hg + fulfill the demands of European legislation for Hg quantification. The limit of detection and quantification were better than those in the used reference method or other non-/chromatographic methods taken for comparison. The analysis of certified reference materials and the Bland and Altman test performed on 12 test samples confirmed trueness of the proposed method and its reliability for the determination of traces of CH 3 Hg + with 95% confidence level. The proposed method fulfills several demands of the eco-scale concept, is sensitive, simple and safe related to sample preparation through elimination of classical, harmful reductants and attractive by using economical miniaturized instrumentation incorporating a low power and low Ar consumption plasma. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Guo, Mengmeng; Wu, Haiyan; Jiang, Tao; Tan, Zhijun; Zhao, Chunxia; Zheng, Guanchao; Li, Zhaoxin; Zhai, Yuxiu
2017-07-01
In this study, we established a comprehensive method for simultaneous identification and quantification of tetrodotoxin (TTX) in fresh pufferfish tissues and pufferfish-based products using liquid chromatography/quadrupole-linear ion trap mass spectrometry (LC-QqLIT-MS). TTX was extracted by 1% acetic acid-methanol, and most of the lipids were then removed by freezing lipid precipitation, followed by purification and concentration using immunoaffinity columns (IACs). Matrix effects were substantially reduced due to the high specificity of the IACs, and thus, background interference was avoided. Quantitation analysis was therefore performed using an external calibration curve with standards prepared in mobile phase. The method was evaluated by fortifying samples at 1, 10, and 100 ng/g, respectively, and the recoveries ranged from 75.8%-107%, with a relative standard deviation of less than 15%. The TTX calibration curves were linear over the range of 1-1 000 μg/L, with a detection limit of 0.3 ng/g and a quantification limit of 1 ng/g. Using this method, samples can be further analyzed using an information-dependent acquisition (IDA) experiment, in the positive mode, from a single liquid chromatography-tandem mass spectrometry injection, which can provide an extra level of confirmation by matching the full product ion spectra acquired for a standard sample with those from an enhanced product ion (EPI) library. The scheduled multiple reaction monitoring method enabled TTX to be screened for, and TTX was positively identified using the IDA and EPI spectra. This method was successfully applied to analyze a total of 206 samples of fresh pufferfish tissues and pufferfish-based products. The results from this study show that the proposed method can be used to quantify and identify TTX in a single run with excellent sensitivity and reproducibility, and is suitable for the analysis of complex matrix pufferfish samples.
Woldemariam, Getachew A.; Butch, Anthony W.
2015-01-01
BACKGROUND Human chorionic gonadotropin (hCG) stimulates testosterone production by the testicles. Because of the potential for abuse, hCG is banned (males only) in most sports and has been placed on the World Anti-Doping Agency list of prohibited substances. Intact hCG, free β-subunit (hCGβ), and β-subunit core fragment (hCGβcf) are the major variants or isoforms in urine. Immunoassays are used by antidoping laboratories to measure urinary hCG. Cross-reactivity with isoforms differs among immunoassays, resulting in widely varying results. We developed a sequential im-munoextraction method with LC-MS/MS detection for quantification of intact hCG, hCGβ, and hCGβcf in urine. METHODS hCG isoforms were immunoextracted with antibody-conjugated magnetic beads and digested with trypsin, and hCGβ and hCGβcf unique peptides were quantified by LC-MS/MS with the corresponding heavy peptides as internal standard. hCG isoform concentrations were determined in urine after administration of hCG, and the intact hCG results were compared to immunoassay results. RESULTS The method was linear to 20 IU/L. Total imprecision was 6.6%-13.7% (CV), recovery ranged from 91% to 109%, and the limit of quantification was 0.2 IU/L. Intact hCG predominated in the urine after administration of 2 hCG formulations. The window of detection ranged from 6 to 9 days. Mean immunoassay results were 12.4-15.5 IU/L higher than LC-MS/MS results. CONCLUSIONS The performance characteristics of the method are acceptable for measuring hCG isoforms, and the method can quantify intact hCG and hCGβ separately. The limit of quantification will allow LC-MS/MS hCG reference intervals to be established in nondoping male athletes for improved doping control. PMID:24899693
Umezawa, Keitaro; Kamiya, Mako; Urano, Yasuteru
2018-05-23
The chemical biology of reactive sulfur species, including hydropolysulfides, has been a subject undergoing intense study in recent years, but further understanding of their 'intact' function in living cells has been limited due to a lack of appropriate analytical tools. In order to overcome this limitation, we developed a new type of fluorescent probe which reversibly and selectively reacts to hydropolysulfides. The probe enables live-cell visualization and quantification of endogenous hydropolysulfides without interference from intrinsic thiol species such as glutathione. Additionally, real-time reversible monitoring of oxidative-stress-induced fluctuation of intrinsic hydropolysulfides has been achieved with a temporal resolution in the order of seconds, a result which has not yet been realized using conventional methods. These results reveal the probe's versatility as a new fluorescence imaging tool to understand the function of intracellular hydropolysulfides. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Alesso, Magdalena; Escudero, Luis A; Talio, María Carolina; Fernández, Liliana P
2016-11-01
A new simple methodology is proposed for chlorsufuron (CS) traces quantification based upon enhancement of rhodamine B (RhB) fluorescent signal. Experimental variables that influence fluorimetric sensitivity have been studied and optimized. The zeroth order regression calibration was linear from 0.866 to 35.800µgL(-1) CS, with a correlation coefficient of 0.99. At optimal experimental conditions, a limit of detection of 0.259µgL(-1) and a limit of quantification of 0.866µgL(-1) were obtained. The method showed good sensitivity and adequate selectivity and was applied to the determination of trace amounts of CS in plasma, serum and water samples with satisfactory results analyzed by ANOVA test. The proposed methodology represents an alternative to traditional chromatographic techniques for CS monitoring in complex samples, using an accessible instrument in control laboratories. Copyright © 2016 Elsevier B.V. All rights reserved.
Improved Quantification of Free and Ester-Bound Gallic Acid in Foods and Beverages by UHPLC-MS/MS.
Newsome, Andrew G; Li, Yongchao; van Breemen, Richard B
2016-02-17
Hydrolyzable tannins are measured routinely during the characterization of food and beverage samples. Most methods for the determination of hydrolyzable tannins use hydrolysis or methanolysis to convert complex tannins to small molecules (gallic acid, methyl gallate, and ellagic acid) for quantification by HPLC-UV. Often unrecognized, analytical limitations and variability inherent in these approaches for the measurement of hydrolyzable tannins include the variable mass fraction (0-0.90) that is released as analyte, contributions of sources other than tannins to hydrolyzable gallate (can exceed >10 wt %/wt), the measurement of both free and total analyte, and lack of controls to account for degradation. An accurate, specific, sensitive, and higher-throughput approach for the determination of hydrolyzable gallate based on ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) that overcomes these limitations was developed.
Quantifying Motor Impairment in Movement Disorders.
FitzGerald, James J; Lu, Zhongjiao; Jareonsettasin, Prem; Antoniades, Chrystalina A
2018-01-01
Until recently the assessment of many movement disorders has relied on clinical rating scales that despite careful design are inherently subjective and non-linear. This makes accurate and truly observer-independent quantification difficult and limits the use of sensitive parametric statistical methods. At last, devices capable of measuring neurological problems quantitatively are becoming readily available. Examples include the use of oculometers to measure eye movements and accelerometers to measure tremor. Many applications are being developed for use on smartphones. The benefits include not just more accurate disease quantification, but also consistency of data for longitudinal studies, accurate stratification of patients for entry into trials, and the possibility of automated data capture for remote follow-up. In this mini review, we will look at movement disorders with a particular focus on Parkinson's disease, describe some of the limitations of existing clinical evaluation tools, and illustrate the ways in which objective metrics have already been successful.
Quantification of six herbicide metabolites in human urine.
Norrgran, Jessica; Bravo, Roberto; Bishop, Amanda M; Restrepo, Paula; Whitehead, Ralph D; Needham, Larry L; Barr, Dana B
2006-01-18
We developed a sensitive, selective and precise method for measuring herbicide metabolites in human urine. Our method uses automated liquid delivery of internal standards and acetate buffer and a mixed polarity polymeric phase solid phase extraction of a 2 mL urine sample. The concentrated eluate is analyzed using high-performance liquid chromatography-tandem mass spectrometry. Isotope dilution calibration is used for quantification of all analytes. The limits of detection of our method range from 0.036 to 0.075 ng/mL. The within- and between-day variation in pooled quality control samples range from 2.5 to 9.0% and from 3.2 to 16%, respectively, for all analytes at concentrations ranging from 0.6 to 12 ng/mL. Precision was similar with samples fortified with 0.1 and 0.25 ng/mL that were analyzed in each run. We validated our selective method against a less selective method used previously in our laboratory by analyzing human specimens using both methods. The methods produced results that were in agreement, with no significant bias observed.
Jahan, Md. Sarowar; Islam, Md. Jahirul; Begum, Rehana; Kayesh, Ruhul; Rahman, Asma
2014-01-01
A rapid and stability-indicating reversed phase high-performance liquid chromatography (RP-HPLC) method was developed for simultaneous quantification of paracetamol and ibuprofen in their combined dosage form especially to get some more advantages over other methods already developed for this combination. The method was validated according to United States Pharmacopeia (USP) guideline with respect to accuracy, precision, specificity, linearity, solution stability, robustness, sensitivity, and system suitability. Forced degradation study was validated according to International Conference on Harmonisation (ICH). For this, an isocratic condition of mobile phase comprising phosphate buffer (pH 6.8) and acetonitrile in a ratio of 65:35, v/v at a flow rate of 0.7 mL/minute over RP C18 (octadecylsilane (ODS), 150 × 4.6 mm, 5 μm, Phenomenex Inc.) column at ambient temperature was maintained. The method showed excellent linear response with correlation coefficient (R2) values of 0.999 and 1.0 for paracetamol and ibuprofen respectively, which were within the limit of correlation coefficient (R2 > 0.995). The percent recoveries for two drugs were found within the acceptance limit of (97.0–103.0%). Intra-and inter-day precision studies of the new method were less than the maximum allowable limit percentage of relative standard deviation (%RSD) ≤ 2.0. Forced degradation of the drug product was carried out as per the ICH guidelines with a view to establishing the stability-indicating property of this method and providing useful information about the degradation pathways, degradation products, and how the quality of a drug substance and drug product changes with time under the influence of various stressing conditions. The degradation of ibuprofen was within the limit (5–20%, according to the guideline of ICH), while paracetamol showed <20% degradation in oxidation and basic condition. PMID:25452691
Jahan, Md Sarowar; Islam, Md Jahirul; Begum, Rehana; Kayesh, Ruhul; Rahman, Asma
2014-01-01
A rapid and stability-indicating reversed phase high-performance liquid chromatography (RP-HPLC) method was developed for simultaneous quantification of paracetamol and ibuprofen in their combined dosage form especially to get some more advantages over other methods already developed for this combination. The method was validated according to United States Pharmacopeia (USP) guideline with respect to accuracy, precision, specificity, linearity, solution stability, robustness, sensitivity, and system suitability. Forced degradation study was validated according to International Conference on Harmonisation (ICH). For this, an isocratic condition of mobile phase comprising phosphate buffer (pH 6.8) and acetonitrile in a ratio of 65:35, v/v at a flow rate of 0.7 mL/minute over RP C18 (octadecylsilane (ODS), 150 × 4.6 mm, 5 μm, Phenomenex Inc.) column at ambient temperature was maintained. The method showed excellent linear response with correlation coefficient (R (2)) values of 0.999 and 1.0 for paracetamol and ibuprofen respectively, which were within the limit of correlation coefficient (R (2) > 0.995). The percent recoveries for two drugs were found within the acceptance limit of (97.0-103.0%). Intra-and inter-day precision studies of the new method were less than the maximum allowable limit percentage of relative standard deviation (%RSD) ≤ 2.0. Forced degradation of the drug product was carried out as per the ICH guidelines with a view to establishing the stability-indicating property of this method and providing useful information about the degradation pathways, degradation products, and how the quality of a drug substance and drug product changes with time under the influence of various stressing conditions. The degradation of ibuprofen was within the limit (5-20%, according to the guideline of ICH), while paracetamol showed <20% degradation in oxidation and basic condition.
Optimization and determination of polycyclic aromatic hydrocarbons in biochar-based fertilizers.
Chen, Ping; Zhou, Hui; Gan, Jay; Sun, Mingxing; Shang, Guofeng; Liu, Liang; Shen, Guoqing
2015-03-01
The agronomic benefit of biochar has attracted widespread attention to biochar-based fertilizers. However, the inevitable presence of polycyclic aromatic hydrocarbons in biochar is a matter of concern because of the health and ecological risks of these compounds. The strong adsorption of polycyclic aromatic hydrocarbons to biochar complicates their analysis and extraction from biochar-based fertilizers. In this study, we optimized and validated a method for determining the 16 priority polycyclic aromatic hydrocarbons in biochar-based fertilizers. Results showed that accelerated solvent extraction exhibited high extraction efficiency. Based on a Box-Behnken design with a triplicate central point, accelerated solvent extraction was used under the following optimal operational conditions: extraction temperature of 78°C, extraction time of 17 min, and two static cycles. The optimized method was validated by assessing the linearity of analysis, limit of detection, limit of quantification, recovery, and application to real samples. The results showed that the 16 polycyclic aromatic hydrocarbons exhibited good linearity, with a correlation coefficient of 0.996. The limits of detection varied between 0.001 (phenanthrene) and 0.021 mg/g (benzo[ghi]perylene), and the limits of quantification varied between 0.004 (phenanthrene) and 0.069 mg/g (benzo[ghi]perylene). The relative recoveries of the 16 polycyclic aromatic hydrocarbons were 70.26-102.99%. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Boyer, Anne E; Gallegos-Candela, Maribel; Quinn, Conrad P; Woolfitt, Adrian R; Brumlow, Judith O; Isbell, Katherine; Hoffmaster, Alex R; Lins, Renato C; Barr, John R
2015-04-01
Inhalation anthrax has a rapid progression and high fatality rate. Pathology and death from inhalation of Bacillus anthracis spores are attributed to the actions of secreted protein toxins. Protective antigen (PA) binds and imports the catalytic component lethal factor (LF), a zinc endoprotease, and edema factor (EF), an adenylyl cyclase, into susceptible cells. PA-LF is termed lethal toxin (LTx) and PA-EF, edema toxin. As the universal transporter for both toxins, PA is an important target for vaccination and immunotherapeutic intervention. However, its quantification has been limited to methods of relatively low analytic sensitivity. Quantification of LTx may be more clinically relevant than LF or PA alone because LTx is the toxic form that acts on cells. A method was developed for LTx-specific quantification in plasma using anti-PA IgG magnetic immunoprecipitation of PA and quantification of LF activity that co-purified with PA. The method was fast (<4 h total time to detection), sensitive at 0.033 ng/mL LTx in plasma for the fast analysis (0.0075 ng/mL LTx in plasma for an 18 h reaction), precise (6.3-9.9% coefficient of variation), and accurate (0.1-12.7%error; n ≥ 25). Diagnostic sensitivity was 100% (n = 27 animal/clinical cases). Diagnostic specificity was 100% (n = 141). LTx was detected post-antibiotic treatment in 6/6 treated rhesus macaques and 3/3 clinical cases of inhalation anthrax and as long as 8 days post-treatment. Over the course of infection in two rhesus macaques, LTx was first detected at 0.101 and 0.237 ng/mL at 36 h post-exposure and increased to 1147 and 12,107 ng/mL in late-stage anthrax. This demonstrated the importance of LTx as a diagnostic and therapeutic target. This method provides a sensitive, accurate tool for anthrax toxin detection and evaluation of PA-directed therapeutics.
Wang, Jian-Hua; Guo, Cui
2010-07-09
An analytical method for the determination of US EPA priority pollutant 16 polycyclic aromatic hydrocarbons (PAHs) in edible oil was developed by an isotope dilution gas chromatography-mass spectrometry (GC-MS). Extraction was performed with ultrasonication mode using acetonitrile as solvent, and subsequent clean-up was applied using narrow gel permeation chromatographic column. Three deuterated PAHs surrogate standards were used as internal standards for quantification and analytical quality control. The limits of quantification (LOQs) were globally below 0.5 ng/g, the recoveries were in the range of 81-96%, and the relative standard deviations (RSDs) were lower than 20%. Further trueness assessment of the method was also verified through participation in international cocoa butter proficiency test (T0638) organised by the FAPAS with excellent results in 2008. The results obtained with the described method were satisfying (z ≤ 2). The method has been applied to determine PAH in real edible oil samples.
NASA Astrophysics Data System (ADS)
Ramanjaneyulu, P. S.; Sayi, Y. S.; Ramakumar, K. L.
2008-08-01
Quantification of boron in diverse materials of relevance in nuclear technology is essential in view of its high thermal neutron absorption cross section. A simple and sensitive method has been developed for the determination of boron in uranium-aluminum-silicon alloy, based on leaching of boron with 6 M HCl and H 2O 2, its selective separation by solvent extraction with 2-ethyl hexane 1,3-diol and quantification by spectrophotometry using curcumin. The method has been evaluated by standard addition method and validated by inductively coupled plasma-atomic emission spectroscopy. Relative standard deviation and absolute detection limit of the method are 3.0% (at 1 σ level) and 12 ng, respectively. All possible sources of uncertainties in the methodology have been individually assessed, following the International Organization for Standardization guidelines. The combined uncertainty is calculated employing uncertainty propagation formulae. The expanded uncertainty in the measurement at 95% confidence level (coverage factor 2) is 8.840%.
Wang, Yongyi; Xu, Jinzhong; Qu, Haibin
2013-01-01
A simple and accurate analytical method was developed for simultaneous quantification of three steroidal saponins in the roots of Ophiopogon japonicus via high-performance liquid chromatography (HPLC) with mass spectrometry (MS) in this study. Separation was performed on a Tigerkin C(18) column and detection was performed by mass spectrometry. A mobile phase consisted of 0.02% formic acid in water (v/v) and 0.02% formic acid in acetonitrile (v/v) was used with a flow rate of 0.5 mL min(-1). The quantitative HPLC-MS method was validated for linearity, precision, repeatability, stability, recovery, limits of detection and quantification. This developed method provides good linearity (r >0.9993), intra- and inter-day precisions (RSD <4.18%), repeatability (RSD <5.05%), stability (RSD <2.08%) and recovery (93.82-102.84%) for three steroidal saponins. It could be considered as a suitable quality control method for O. japonicus.
Sun, Juan; Li, Weixi; Zhang, Yan; Hu, Xuexu; Wu, Li; Wang, Bujun
2016-12-15
A method based on the QuEChERS (quick, easy, cheap, effective, rugged, and safe) purification combined with ultrahigh performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS), was optimized for the simultaneous quantification of 25 mycotoxins in cereals. Samples were extracted with a solution containing 80% acetonitrile and 0.1% formic acid, and purified with QuEChERS before being separated by a C18 column. The mass spectrometry was conducted by using positive electrospray ionization (ESI+) and multiple reaction monitoring (MRM) models. The method gave good linear relations with regression coefficients ranging from 0.9950 to 0.9999. The detection limits ranged from 0.03 to 15.0 µg·kg -1 , and the average recovery at three different concentrations ranged from 60.2% to 115.8%, with relative standard deviations (RSD%) varying from 0.7% to 19.6% for the 25 mycotoxins. The method is simple, rapid, accurate, and an improvement compared with the existing methods published so far.
Cereal β-glucan quantification with calcofluor-application to cell culture supernatants.
Rieder, Anne; Knutsen, Svein H; Ballance, Simon; Grimmer, Stine; Airado-Rodríguez, Diego
2012-11-06
The specific binding of the fluorescent dye calcofluor to cereal β-glucan results in increased fluorescence intensity of the formed complex and is in use for the quantification of β-glucan above a critical molecular weight (MW) by flow injection analysis. In this study, this method was applied in a fast and easy batch mode. In order to emphasize the spectral information of the emission spectra of the calcofluor/β-glucan complexes, derivative signals were calculated. A linear relationship was found between the amplitude of the second derivative signals and the β-glucan concentration between 0.1 and 0.4 μg/mL. The low detection limit of this new method (0.045 μg/mL) enabled its use to study the transport of cereal β-glucans over differentiated Caco-2 cell monolayers. Additionally, the method was applied to quantify β-glucan in arabinoxylan samples, which correlated well with data by an enzyme based method. Copyright © 2012 Elsevier Ltd. All rights reserved.
Ostry, Vladimir; Malir, Frantisek; Dofkova, Marcela; Skarkova, Jarmila; Pfohl-Leszkowicz, Annie; Ruprich, Jiri
2015-01-01
Ochratoxin A is a nephrotoxic and renal carcinogenic mycotoxin and is a common contaminant of various food commodities. Eighty six kinds of foodstuffs (1032 food samples) were collected in 2011–2013. High-performance liquid chromatography with fluorescence detection was used for ochratoxin A determination. Limit of quantification of the method varied between 0.01–0.2 μg/kg depending on the food matrices. The most exposed population is children aged 4–6 years old. Globally for this group, the maximum ochratoxin A dietary exposure for “average consumer” was estimated at 3.3 ng/kg bw/day (lower bound, considering the analytical values below the limit of quantification as 0) and 3.9 ng/kg bw/day (middle bound, considering the analytical values below the limit of quantification as 1/2 limit of quantification). Important sources of exposure for this latter group include grain-based products, confectionery, meat products and fruit juice. The dietary intake for “high consumers” in the group 4–6 years old was estimated from grains and grain-based products at 19.8 ng/kg bw/day (middle bound), from tea at 12.0 ng/kg bw/day (middle bound) and from confectionery at 6.5 ng/kg bw/day (middle bound). For men aged 18–59 years old beer was the main contributor with an intake of 2.60 ng/kg bw/day (“high consumers”, middle bound). Tea and grain-based products were identified to be the main contributors for dietary exposure in women aged 18–59 years old. Coffee and wine were identified as a higher contributor of the OTA intake in the population group of women aged 18–59 years old compared to the other population groups. PMID:26378578
Espina-Benitez, Maria; Araujo, Lilia; Prieto, Avismelsi; Navalón, Alberto; Vílchez, José Luis; Valera, Paola; Zambrano, Ana; Dugas, Vincent
2017-07-07
A new analytical method coupling a (off-line) solid-phase microextraction with an on-line capillary electrophoresis (CE) sample enrichment technique was developed for the analysis of ketoprofen, naproxen and clofibric acid from water samples, which are known as contaminants of emerging concern in aquatic environments. New solid-phase microextraction fibers based on physical coupling of chromatographic supports onto epoxy glue coated needle were studied for the off-line preconcentration of these micropollutants. Identification and quantification of such acidic drugs were done by capillary zone electrophoresis (CZE) using ultraviolet diode array detection (DAD). Further enhancement of concentration sensitivity detection was achieved by on-line CE "acetonitrile stacking" preconcentration technique. Among the eight chromatographic supports investigated, Porapak Q sorbent showed higher extraction and preconcentration capacities. The screening of parameters that influence the microextraction process was carried out using a two-level fractional factorial. Optimization of the most relevant parameters was then done through a surface response three-factor Box-Behnken design. The limits of detection and limits of quantification for the three drugs ranged between 0.96 and 1.27 µg∙L -1 and 2.91 and 3.86 µg∙L -1 , respectively. Recovery yields of approximately 95 to 104% were measured. The developed method is simple, precise, accurate, and allows quantification of residues of these micropollutants in Genil River water samples using inexpensive fibers.
Remeur, Camille; Le Borgne, Erell; Gauthier, Léa; Grougnet, Raphaël; Deguin, Brigitte; Poullain, Cyril; Litaudon, Marc
2017-05-01
Iridoid glycosides possess highly functionalised monoterpenoid aglycon with several contiguous stereocentres. For the most common, they are often present in quantities reaching several percentage of the fresh plant weight, and thus they may be regarded as starting material for the synthesis of a number of new chiral and bioactive molecules. To quantify and to isolate 8-O-acetylharpagide (AH) from several extracts of Oxera coronata R.P.J. de Kok, a Lamiaceae species endemic to New Caledonia, using HPLC-ELSD (evaporative light scattering detector) and centrifugal partition chromatography (CPC). Oxera coronata produces high amounts of AH in leaves, twigs and fruits. Water and methanol extracts of these plant parts were prepared. The content of AH in each extract was quantified by HPLC-ELSD, using acetonitrile-water (+0.1% formic acid) gradient elution. The HPLC method was validated for precision, linearity, limit of detection (LOD), limit of quantification (LOQ) and accuracy. A ternary solvent system ethyl acetate/n-propanol/water (3:2:5, v/v/v) was selected and applied to recover the target compound using Spot CPC from the leaves aqueous extract. HPLC-ELSD analysis followed by CPC purification led to the efficient isolation of AH from O. coronata leaves aqueous extract. HPLC-ELSD has proven to be a well-adapted detection and quantification method for iridoid glycosides, while CPC confirmed to be an efficient technique for the isolation of polar compounds. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Araujo, Lilia; Prieto, Avismelsi; Navalón, Alberto; Vílchez, José Luis; Valera, Paola; Zambrano, Ana; Dugas, Vincent
2017-01-01
A new analytical method coupling a (off-line) solid-phase microextraction with an on-line capillary electrophoresis (CE) sample enrichment technique was developed for the analysis of ketoprofen, naproxen and clofibric acid from water samples, which are known as contaminants of emerging concern in aquatic environments. New solid-phase microextraction fibers based on physical coupling of chromatographic supports onto epoxy glue coated needle were studied for the off-line preconcentration of these micropollutants. Identification and quantification of such acidic drugs were done by capillary zone electrophoresis (CZE) using ultraviolet diode array detection (DAD). Further enhancement of concentration sensitivity detection was achieved by on-line CE “acetonitrile stacking” preconcentration technique. Among the eight chromatographic supports investigated, Porapak Q sorbent showed higher extraction and preconcentration capacities. The screening of parameters that influence the microextraction process was carried out using a two-level fractional factorial. Optimization of the most relevant parameters was then done through a surface response three-factor Box-Behnken design. The limits of detection and limits of quantification for the three drugs ranged between 0.96 and 1.27 µg∙L−1 and 2.91 and 3.86 µg∙L−1, respectively. Recovery yields of approximately 95 to 104% were measured. The developed method is simple, precise, accurate, and allows quantification of residues of these micropollutants in Genil River water samples using inexpensive fibers. PMID:28686186
Krachler, M; Irgolic, K J
1999-11-01
The advantages accruing to biochemical and clinical investigations from a method that allows the simultaneous quantification (RSD < or = 10%) of many elements in blood, plasma, and serum at concentrations equal to one-hundredth of the lower limits of the normal ranges are undeniable. The suitability of inductively coupled argon plasma low-resolution quadrupole mass spectrometry (ICP-MS), a simultaneous method with low detection limits, is evaluated for the quantification of inorganic constituents in whole blood, plasma, and serum with consideration of the dilution associated with the mineralization of the samples, of isobaric and polyatomic interferences and of normal ranges. Of the 3 bulk elements, the 3 major electrolytes, the 15 essential elements, the 8 toxic elements, the 4 therapeutic elements, and the 14 elements of potential interest (total of 47 elements) only 7 elements (Ca, Cu, K, Mg, Rb, Sr, Zn) can be simultaneously quantified under these rigorous conditions in serum and only 8 elements (additional element Pb) in whole blood. Quantification of elements in the Seronorm Standards "Whole Blood" and "Serum" showed, that this list of simultaneously determinable elements in these matrices is reasonable. Although this list is disappointingly short, the number of elements determinable simultaneously by ICP-MS is still larger than that by ICP-AES or GFAAS. Improved detectors, more efficient nebulizers, avoidance of interferences, better instrument design, and high-resolution mass spectrometers promise to increase the number of elements that can be determined simultaneously.
Song, Xuqin; Zhou, Tong; Li, Jiufeng; Zhang, Meiyu; Xie, Jingmeng; He, Limin
2018-05-14
With the extensive application of antibiotics in livestock, their contamination of the aquatic environment has received more attention. Molecularly imprinted polymer (MIP), as an eco-friendly and durable solid-phase extraction material, has shown great potential for the separation and enrichment of antibiotics in water. This study aims at developing a practical and economical method based on molecularly imprinted solid phase extraction (MISPE) combined with liquid chromatography-tandem mass spectrometry (LC-MS/MS) for simultaneously detecting ten macrolide drugs in different sources of water samples. The MIP was synthesized by bulk polymerization using tylosin as the template and methacrylic acid as the functional monomer. The MIP exhibited a favorable load-bearing capacity for water (>90 mL), which is more than triple that of non-molecularly imprinted polymers (NIP). The mean recoveries of macrolides at four spiked concentration levels (limit of quantification, 40, 100, and 400 ng/L) were 62.6⁻100.9%, with intra-day and inter-day relative standard deviations below 12.6%. The limit of detection and limit of quantification were 1.0⁻15.0 ng/L and 3.0⁻40.0 ng/L, respectively. Finally, the proposed method was successfully applied to the analysis of real water samples.
Ramos, Rhayanne T M; Bezerra, Isabelle C F; Ferreira, Magda R A; Soares, Luiz Alberto Lira
2017-01-01
The traditional use of Eugenia uniflora L. ("Pitanga") is reported due to several properties, which have often been related to its flavonoid content. The aim was to evaluate analytical procedures for quantification of total flavonoids content (TFCs) by ultraviolet-visible (UV-Vis) spectrophotometry in the herbal material (HM), crude extract (CE), and fractions from leaves of E. uniflora . The method for quantification of flavonoids after complexation with aluminum chloride (AlCl 3 ) was evaluated: amount of sample (0.25-1.5 g); solvent (40%-80% ethanol); reaction time and AlCl 3 concentration (2.5%-7.5%). The procedures by direct dilution (DD) and after acid hydrolysis (AH) were used and validated for HM and CE and applied to the aqueous fraction (AqF), hexane fraction, and ethyl acetate fractions (EAF). The ideal conditions of analysis were ethanol 80% as solvent; 0.5 g of sample; λmax of 408 (DD) and 425 nm (AH); 25 min after addition of AlCl 3 5%. The procedures validated for standards and samples showed linearity ( R 2 > 0.99) with limit of detection and limit of quantification between 0.01 and 0.17 mg/mL (rutin and quercetin); and 0.03 and 0.09 mg/mL (quercetin), for DD and AH, respectively. The procedures were accurate (detect, practice, and repair < 5% and recovery >90%), and stable under robustness conditions (luminosity, storage, reagents, and equipment). The TFCs in AqF and EAF were 0.65 g% and 17.72 g%, calculated as rutin. UV-Vis methods for quantification of TFC in HM, CE, and fractions from leaves of E. uniflora were suitably validated. Regarding the analysis of fractions, the EAF achieved enrichment of about nine times in the content of flavonoids. The total flavonoids content (TFCs) of herbal material, crude extract, and fractions from Eugenia uniflora can be quantified by ultraviolet-visibleThe spectrophotometric methods (direct dilution and acid hydrolysis) were reproducible and able to quantify TFC in raw material and derivatives from leaves of E. uniflora Higher flavonoids content was observed in ethyl acetate fractions after enrichment. Abbreviations Used : HM: Herbal material, CE: Crude extract, AqF: Aqueous fraction, HF: Hexanic fraction, EAF: Ethyl acetate fraction, TFC: Total flavonoids content, HCl: Hydrochloric acid, DD: Direct dilution, AH: After hydrolysis, RSD: Relative standard, A.U.: Absorption units.
Fayd’herbe de Maudave, Alexis; Bollore, Karine; Zimmermann, Valérie; Foulongne, Vincent; Van de Perre, Philippe; Tuaillon, Edouard
2017-01-01
Background Viral load monitoring and early Epstein-Barr virus (EBV) DNA detection are essential in routine laboratory testing, especially in preemptive management of Post-transplant Lymphoproliferative Disorder. Targeting the repetitive BamHI-W sequence was shown to increase the sensitivity of EBV DNA quantification, but the variability of BamHI-W reiterations was suggested to be a source of quantification bias. We aimed to assess the extent of variability associated with BamHI-W PCR and its impact on the sensitivity of EBV DNA quantification using the 1st WHO international standard, EBV strains and clinical samples. Methods Repetitive BamHI-W- and LMP2 single- sequences were amplified by in-house qPCRs and BXLF-1 sequence by a commercial assay (EBV R-gene™, BioMerieux). Linearity and limits of detection of in-house methods were assessed. The impact of repeated versus single target sequences on EBV DNA quantification precision was tested on B95.8 and Raji cell lines, possessing 11 and 7 copies of the BamHI-W sequence, respectively, and on clinical samples. Results BamHI-W qPCR demonstrated a lower limit of detection compared to LMP2 qPCR (2.33 log10 versus 3.08 log10 IU/mL; P = 0.0002). BamHI-W qPCR underestimated the EBV DNA load on Raji strain which contained fewer BamHI-W copies than the WHO standard derived from the B95.8 EBV strain (mean bias: - 0.21 log10; 95% CI, -0.54 to 0.12). Comparison of BamHI-W qPCR versus LMP2 and BXLF-1 qPCR showed an acceptable variability between EBV DNA levels in clinical samples with the mean bias being within 0.5 log10 IU/mL EBV DNA, whereas a better quantitative concordance was observed between LMP2 and BXLF-1 assays. Conclusions Targeting BamHI-W resulted to a higher sensitivity compared to LMP2 but the variable reiterations of BamHI-W segment are associated with higher quantification variability. BamHI-W can be considered for clinical and therapeutic monitoring to detect an early EBV DNA and a dynamic change in viral load. PMID:28850597
Multi-residue method for the determination of antibiotics and some of their metabolites in seafood.
Serra-Compte, Albert; Álvarez-Muñoz, Diana; Rodríguez-Mozaz, Sara; Barceló, Damià
2017-06-01
The presence of antibiotics in seafood for human consumption may pose a risk for consumers. A methodology for the analysis of antibiotics in seafood based on QuEChERS (quick, easy, cheap, effective, rugged, and safe) extraction, followed by detection and quantification using liquid chromatography coupled to mass spectrometry was developed. The analytical method was evaluated for the determination of 23 antibiotics (including parent compounds and some metabolites) in fish, mussels and clams. Recoveries ranged between 30% and 70% for most of the compounds and method detection and quantification limits (MDLs and MQLs) were between 0.01 and 0.31 ng/g dry weigh (dw) and 0.02-1.03 ng/g (dw) respectively. Real seafood samples were analysed using this method. Nine antibiotics were found at levels above MDLs; however none of them exceed the maximum residue limits (MRL) established by the authorities. Tetracycline was the most ubiquitous compound, presenting also the highest concentration: 5.63 ng/g (dw) in fish from Netherlands. In addition, an alternative technique based on microbial growth inhibition was explored as semiquantitative detection method of antibiotics in seafood. This methodology could be applied as a fast screening technique for the detection of macrolides and β-lactams in seafood but further research is needed for other antibiotics families. Copyright © 2016 Elsevier Ltd. All rights reserved.
Sagi, Satyanarayanaraju; Avula, Bharathi; Wang, Yan-Hong; Khan, Ikhlas A
2016-01-01
A new UHPLC-UV method has been developed for the simultaneous analysis of seven alkaloids [ajmaline (1), yohimbine (2), corynanthine (3), ajmalicine (4), serpentine (5), serpentinine (6), and reserpine (7)] from the root samples of Rauwolfia serpentina (L.) Benth. ex Kurz. The chromatographic separation was achieved using a reversed phase C18 column with a mobile phase of water and acetonitrile, both containing 0.05% formic acid. The seven compounds were completely separated within 8 min at a flow rate of 0.2 mL/min with a 2-μL injection volume. The method is validated for linearity, accuracy, repeatability, limits of detection (LOD), and limits of quantification (LOQ). Seven plant samples and 21 dietary supplements claiming to contain Rauwolfia roots were analyzed and content of total alkaloids (1-7) varied, namely, 1.57-12.1 mg/g dry plant material and 0.0-4.5 mg/day, respectively. The results indicated that commercial products are of variable quality. The developed analytical method is simple, economic, fast, and suitable for quality control analysis of Rauwolfia samples and commercial products. The UHPLC-QToF-mass spectrometry with electrospray ionization (ESI) interface method is described for the confirmation and characterization of alkaloids from plant samples. This method involved the detection of [M + H](+) or M(+) ions in the positive mode.
NASA Astrophysics Data System (ADS)
Feliciano Crespo, Raquel; Perales Perez, Oscar Juan; Ramirez, C.
2018-05-01
Health diseases due to the ingestion of water or food contaminated with pathogenic microorganisms are a main health problem around the world. The traditional methods for detecting foodborne pathogens are time-consuming (on the order of days). The development of methods that can help to detect and identify foodborne pathogens with high sensitivity and specificity have been proposed to overcome the limitations of traditional methods. Accordingly, this research is focused on the development of an experimental protocol for a high-sensitivity detection and quantification of bacterial pathogens with reduced detection times. This will lead to the development of a portable and low-cost technology with the opportunity to make onsite detection of pathogenic species. The proposed approach has modified the route reported in the literature; the method proposed is expected to be sensitive enough to detect a low limit of 102 CFU/mL counts of bacteria. The fluorescence-based method was tested in presence of Salmonella typhimurium (ATCC 14020) and Escherichia coli (ATCC 25922). CdSe water-soluble quantum dots (QDs) were synthesized in aqueous phase in presence of thioglycolic acid (TGA) as a capping agent. As-synthesized QDs were characterized by x-ray diffraction, near infrared and Fourier transform infrared spectroscopy, UV-Vis and photoluminescence techniques. Results of the CdSe/TGA-bacteria coupling and the determination of the corresponding quantification profiles (calibration curves) will be presented and discussed.
Chen, Lei; Mei, Meng; Huang, Xiaojia; Yuan, Dongxing
2016-05-15
A simple, sensitive and environmentally friendly method using polymeric ionic liquid-based stir cake sorptive extraction followed by high performance liquid chromatography with diode array detection (HPLC/DAD) has been developed for efficient quantification of six selected estrogens in environmental waters. To extract trace estrogens effectively, a poly (1-ally-3-vinylimidazolium chloride-co-ethylene dimethacrylate) monolithic cake was prepared and used as the sorbent of stir cake sorptive extraction (SCSE). The effects of preparation conditions of sorbent and extraction parameters of SCSE for estrogens were investigated and optimized. Under optimal conditions, the developed method showed satisfactory analytical performance for targeted analytes. Low limits of detection (S/N=3) and quantification limits (S/N=10) were achieved within the range of 0.024-0.057 µg/L and 0.08-0.19 µg/L, respectively. Good linearity of method was obtained for analytes with the correlation coefficients (R(2)) above 0.99. At the same time, satisfactory method repeatability and reproducibility was achieved in terms of intra- and inter-day precisions, respectively. Finally, the established SCSE-HPLC/DAD method was successfully applied for the determination of estrogens in different environmental water samples. Recoveries obtained for the determination of estrogens in spiked samples ranged from 71.2% to 108%, with RSDs below 10% in all cases. Copyright © 2016 Elsevier B.V. All rights reserved.
Gautam, Maheswor; Fomsgaard, Inge S
2017-12-01
Lettuce is an important part of the diet in Europe. The permitted levels of pesticides in lettuce are strictly regulated and there is growing urge among food safety authorities to analyse pesticide metabolites as well. Azoxystrobin is one of pesticides that is frequently detected in lettuce. Although there are several analytical methods for the determination of azoxystrobin in lettuce, a sensitive method for the determination of its metabolites in lettuce is lacking. This study aimed at developing an extraction and LC-MS/MS method for the simultaneous determination of azoxystrobin, and its metabolites azoxystrobin free acid and 2-hydroxybenzonitrile in lettuce. Accelerated solvent extraction, QuEChERS extraction, and shaking extraction were compared using various solvents. The final method consisted of shaking freeze-dried sample in 0.1% formic acid in 80% aqueous acetonitrile. The selected method was validated by spiking each analyte at 125 ng/g and 500 ng/g. The method resulted in acceptable recovery for 2-hydroxybenzonitrile, azoxystrobin free acid, and azoxystrobin, with a RSD of <10%. The matrix-matched calibration curve for each analyte was linear over the range of quantification, with a correlation coefficient ≥0.98. The method was sensitive for the determination of 2-hydroxybenzonitrile, azoxystrobin free acid, and azoxystrobin, with limits of quantification of 0.36, 0.48, and 0.68 ng/g dry weight, respectively. The method was successfully applied to quantify 2-hydroxybenzonitrile, azoxystrobin free acid, and azoxystrobin in greenhouse-grown lettuce.
Normal Databases for the Relative Quantification of Myocardial Perfusion
Rubeaux, Mathieu; Xu, Yuan; Germano, Guido; Berman, Daniel S.; Slomka, Piotr J.
2016-01-01
Purpose of review Myocardial perfusion imaging (MPI) with SPECT is performed clinically worldwide to detect and monitor coronary artery disease (CAD). MPI allows an objective quantification of myocardial perfusion at stress and rest. This established technique relies on normal databases to compare patient scans against reference normal limits. In this review, we aim to introduce the process of MPI quantification with normal databases and describe the associated perfusion quantitative measures that are used. Recent findings New equipment and new software reconstruction algorithms have been introduced which require the development of new normal limits. The appearance and regional count variations of normal MPI scan may differ between these new scanners and standard Anger cameras. Therefore, these new systems may require the determination of new normal limits to achieve optimal accuracy in relative myocardial perfusion quantification. Accurate diagnostic and prognostic results rivaling those obtained by expert readers can be obtained by this widely used technique. Summary Throughout this review, we emphasize the importance of the different normal databases and the need for specific databases relative to distinct imaging procedures. use of appropriate normal limits allows optimal quantification of MPI by taking into account subtle image differences due to the hardware and software used, and the population studied. PMID:28138354
Zhang, Yanqing; Xie, Junbo; Chen, Wen-Qian; Zhou, Tian-Yan; Lu, Wei
2009-01-01
A sensitive HPLC method with simple extraction was developed for simultaneous determination of huperzine A (HupA) and huperzine B (HupB) in Huperzia serrata, H. crispata, H. miyoshiana, and Lycopodiastrum casuarinoides. In order to avoid conventional multiple-step and time-consuming sample preparation methods, direct reflux extraction with alkaline chloroform was adopted. The quantitative determination was conducted by reversed-phase HPLC with a photodiode array detector set at 308 nm. Separation was performed on a Luna C18 column (250 x 4.6 mm id, 5 microm) with methanol-0.2% aqueous acetic acid (18 + 82, v/v) mobile phase. The method was validated for accuracy, reproducibility, precision, and limits of detection and quantification. Quantification of the two active compounds in the samples was performed by this newly developed method, and the content of HupA and HupB varied substantially among four different species. The satisfactory results indicated that the developed method can readily be utilized for quality control of the species of Huperziaceae and Lycopodiaceae containing the two compounds.
2013-01-01
Influenza virus-like particle vaccines are one of the most promising ways to respond to the threat of future influenza pandemics. VLPs are composed of viral antigens but lack nucleic acids making them non-infectious which limit the risk of recombination with wild-type strains. By taking advantage of the advancements in cell culture technologies, the process from strain identification to manufacturing has the potential to be completed rapidly and easily at large scales. After closely reviewing the current research done on influenza VLPs, it is evident that the development of quantification methods has been consistently overlooked. VLP quantification at all stages of the production process has been left to rely on current influenza quantification methods (i.e. Hemagglutination assay (HA), Single Radial Immunodiffusion assay (SRID), NA enzymatic activity assays, Western blot, Electron Microscopy). These are analytical methods developed decades ago for influenza virions and final bulk influenza vaccines. Although these methods are time-consuming and cumbersome they have been sufficient for the characterization of final purified material. Nevertheless, these analytical methods are impractical for in-line process monitoring because VLP concentration in crude samples generally falls out of the range of detection for these methods. This consequently impedes the development of robust influenza-VLP production and purification processes. Thus, development of functional process analytical techniques, applicable at every stage during production, that are compatible with different production platforms is in great need to assess, optimize and exploit the full potential of novel manufacturing platforms. PMID:23642219
Binding, N; Schilder, K; Czeschinski, P A; Witting, U
1998-08-01
The 2,4-dinitrophenylhydrazine (2,4-DNPH) derivatization method mainly used for the determination of airborne formaldehyde was extended for acetaldehyde, acetone, 2-butanone, and cyclohexanone, the next four carbonyl compounds of industrial importance. Sampling devices and sampling conditions were adjusted for the respective limit value regulations. Analytical reliability criteria were established and compared to those of other recommended methods. With a minimum analytical range from one tenth to the 3-fold limit value in all cases and with relative standard deviations below 5%, the adjusted method meets all requirements for the reliable quantification of the four compounds in workplace air as well as in ambient air.
de Macedo, A. N.; Vicente, G. H. L.; Nogueira, A. R. A.
2010-01-01
A method for the determination of pesticide residues in water and sediment was developed using the QuEChERS method followed by gas chromatography – mass spectrometry. The method was validated in terms of accuracy, specificity, linearity, detection and quantification limits. The recovery percentages obtained for the pesticides in water at different concentrations ranged from 63 to 116%, with relative standard deviations below 12%. The corresponding results from the sediment ranged from 48 to 115% with relative standard deviations below 16%. The limits of detection for the pesticides in water and sediment were below 0.003 mg L−1 and 0.02 mg kg−1, respectively. PMID:21165598
Kahsay, Getu; Shraim, Fairouz; Villatte, Philippe; Rotger, Jacques; Cassus-Coussère, Céline; Van Schepdael, Ann; Hoogmartens, Jos; Adams, Erwin
2013-03-05
A simple, robust and fast high-performance liquid chromatographic method is described for the analysis of oxytetracycline and its related impurities. The principal peak and impurities are all baseline separated in 20 min using an Inertsil C₈ (150 mm × 4.6 mm, 5 μm) column kept at 50 °C. The mobile phase consists of a gradient mixture of mobile phases A (0.05% trifluoroacetic acid in water) and B (acetonitrile-methanol-tetrahydrofuran, 80:15:5, v/v/v) pumped at a flow rate of 1.3 ml/min. UV detection was performed at 254 nm. The developed method was validated for its robustness, sensitivity, precision and linearity in the range from limit of quantification (LOQ) to 120%. The limits of detection (LOD) and LOQ were found to be 0.08 μg/ml and 0.32 μg/ml, respectively. This method allows the separation of oxytetracycline from all known and 5 unknown impurities, which is better than previously reported in the literature. Moreover, the simple mobile phase composition devoid of non-volatile buffers made the method suitable to interface with mass spectrometry for further characterization of unknown impurities. The developed method has been applied for determination of related substances in oxytetracycline bulk samples available from four manufacturers. The validation results demonstrate that the method is reliable for quantification of oxytetracycline and its impurities. Copyright © 2012 Elsevier B.V. All rights reserved.
Chen, Qi; Zhang, Jingshun; Ke, Xing; Lai, Shiyun; Li, Duo; Yang, Jinchuan; Mo, Weimin; Ren, Yiping
2016-09-01
In recent years, there is an increasing need to measure the concentration of individual proteins in human milk, instead of total human milk proteins. Due to lack of human milk protein standards, there are only few quantification methods established. The objective of the present work was to develop a simple and rapid quantification method for simultaneous determination of α-lactalbumin and β-casein in human milk using signature peptides according to a modified quantitative proteomics strategy. The internal standards containing the signature peptide sequences were synthesized with isotope-labeled amino acids. The purity of synthesized peptides as standards was determined by amino acid analysis method and area normalization method. The contents of α-lactalbumin and β-casein in human milk were measured according to the equimolar relationship between the two proteins and their corresponding signature peptides. The method validation results showed a satisfied linearity (R(2)>0.99) and recoveries (97.2-102.5% for α-lactalbumin and 99.5-100.3% for β-casein). The limit of quantification for α-lactalbumin and β-casein was 8.0mg/100g and 1.2mg/100g, respectively. CVs for α-lactalbumin and β-casein in human milk were 5.2% and 3.0%. The contents of α-lactalbumin and β-casein in 147 human milk samples were successfully determined by the established method and their contents were 205.5-578.2mg/100g and 116.4-467.4mg/100g at different lactation stages. The developed method allows simultaneously determination of α-lactalbumin and β-casein in human milk. The quantitative strategy based on signature peptide should be applicable to other endogenous proteins in breast milk and other body fluids. Copyright © 2016 Elsevier B.V. All rights reserved.
Chatterjee, Arnab; Kumar, Satyanshu; Chattopadhyay, Sunil K
2013-12-01
A simple, rapid, accurate and reproducible reverse-phase HPLC method has been developed for the identification and quantification of two alkaloids ephedrine and cryptolepine in different extracts of Sida species using photodiode array detection. Baseline separation of the two alkaloids was achieved on a Waters RP-18 X-terra column (250 × 4.6 mm, 5 µm) using a solvent system consisting of a mixture of water containing 0.1% Trifluoroacetic acid (TFA) and acetonitrile in a gradient elution mode with detection at 210 and 280 nm for ephedrine and cryptolepine, respectively. The calibration curves were linear in a concentration range of 10-250 µg/mL for both the alkaloids with correlation coefficient values >0.99. The limits of detection and quantification for ephedrine and cryptolepine were 5 and 10 µg/mL and 2.5 and 5 µg/mL, respectively. Relative standard deviation values for intra-day and inter-day precision were 1.22 and 1.04% for ephedrine and 1.71 and 2.06% for cryptolepine, respectively. Analytical recovery ranged from 92.46 to 103.95%. The developed HPLC method was applied to identify and quantify ephedrine and cryptolepine in different extracts of Sida species. Copyright © 2013 John Wiley & Sons, Ltd.
Zhang, Dan; Park, Jin-A; Kim, Seong-Kwan; Cho, Sang-Hyun; Cho, Soo-Min; Shim, Jae-Han; Kim, Jin-Suk; Abd El-Aty, A M; Shin, Ho-Chul
2017-06-01
In this study, an analytical method was developed for quantification of residues of the anthelmintic drug phenothiazine (PTZ) in pork muscle using liquid chromatography-tandem mass spectrometry. Muscles were extracted using 0.2% formic acid and 10 mm ammonium formate in acetonitrile, defatted and purified using n-hexane. The drug was well separated on a Waters XBridge™ C 18 analytical column using a binary solvent system consisting of 0.2% formic acid and 10 mm ammonium formate in ultrapure water (A) and acetonitrile (B). Good linearity was achieved over a six-point concentration range in matrix-matched calibration with determination coefficient =0.9846. Fortified pork muscle having concentrations equivalent to and double the limit of quantification (1 ng/g) yielded recovery ranges between 100.82 and 104.03% and relative standard deviations <12%. Samples (n = 5) collected from large markets located in Seoul City tested negative for PTZ residue. In conclusion, 0.2% formic acid and ammonium formate in acetonitrile can effectively extract PTZ from pork muscle without solid-phase extraction, a step normally required for cleanup before analysis and the validated method can be used for routine analysis to ensure the quality of animal products. Copyright © 2016 John Wiley & Sons, Ltd.
Lesion Quantification in Dual-Modality Mammotomography
NASA Astrophysics Data System (ADS)
Li, Heng; Zheng, Yibin; More, Mitali J.; Goodale, Patricia J.; Williams, Mark B.
2007-02-01
This paper describes a novel x-ray/SPECT dual modality breast imaging system that provides 3D structural and functional information. While only a limited number of views on one side of the breast can be acquired due to mechanical and time constraints, we developed a technique to compensate for the limited angle artifact in reconstruction images and accurately estimate both the lesion size and radioactivity concentration. Various angular sampling strategies were evaluated using both simulated and experimental data. It was demonstrated that quantification of lesion size to an accuracy of 10% and quantification of radioactivity to an accuracy of 20% are feasible from limited-angle data acquired with clinically practical dosage and acquisition time
Multi-temporal LiDAR and Landsat quantification of fire-induced changes to forest structure
T. Ryan McCarley; Crystal A. Kolden; Nicole M. Vaillant; Andrew T. Hudak; Alistair M. S. Smith; Brian M. Wing; Bryce S. Kellogg; Jason Kreitler
2017-01-01
Measuring post-fire effects at landscape scales is critical to an ecological understanding of wildfire effects. Predominantly this is accomplished with either multi-spectral remote sensing data or through ground-based field sampling plots.While these methods are important, field data is usually limited to opportunistic post-fire observations, and spectral data often...
Algorithm Diversity for Resilent Systems
2016-06-27
data structures. 15. SUBJECT TERMS computer security, software diversity, program transformation 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF 18...systematic method for transforming Datalog rules with general universal and existential quantification into efficient algorithms with precise complexity...worst case in the size of the ground rules. There are numerous choices during the transformation that lead to diverse algorithms and different
ERIC Educational Resources Information Center
Hussmann, Katja; Grande, Marion; Meffert, Elisabeth; Christoph, Swetlana; Piefke, Martina; Willmes, Klaus; Huber, Walter
2012-01-01
Although generally accepted as an important part of aphasia assessment, detailed analysis of spontaneous speech is rarely carried out in clinical practice mostly due to time limitations. The Aachener Sprachanalyse (ASPA; Aachen Speech Analysis) is a computer-assisted method for the quantitative analysis of German spontaneous speech that allows for…
Li, Xiang; Pan, Liangwen; Li, Junyi; Zhang, Qigang; Zhang, Shuya; Lv, Rong; Yang, Litao
2011-12-28
For implementation of the issued regulations and labeling policies for genetically modified organism (GMO) supervision, the polymerase chain reaction (PCR) method has been widely used due to its high specificity and sensitivity. In particular, use of the event-specific PCR method based on the flanking sequence of transgenes has become the primary trend. In this study, both qualitative and quantitative PCR methods were established on the basis of the 5' flanking sequence of transgenic soybean A2704-12 and the 3' flanking sequence of transgenic soybean A5547-127, respectively. In qualitative PCR assays, the limits of detection (LODs) were 10 copies of haploid soybean genomic DNA for both A2704-12 and A5547-127. In quantitative real-time PCR assays, the LODs were 5 copies of haploid soybean genomic DNA for both A2704-12 and A5547-127, and the limits of quantification (LOQs) were 10 copies for both. Low bias and acceptable SD and RSD values were also achieved in quantification of four blind samples using the developed real-time PCR assays. In addition, the developed PCR assays for the two transgenic soybean events were used for routine analysis of soybean samples imported to Shanghai in a 6 month period from October 2010 to March 2011. A total of 27 lots of soybean from the United States and Argentina were analyzed: 8 lots from the Unites States were found to have the GM soybean A2704-12 event, and the GM contents were <1.5% in all eight analyzed lots. On the contrary, no GM soybean A5547-127 content was found in any of the eight lots. These results demonstrated that the established event-specific qualitative and quantitative PCR methods could be used effectively in routine identification and quantification of GM soybeans A2704-12 and A5547-127 and their derived products.
Bhusal, Prabhat; Sharma, Manisha; Harrison, Jeff; Procter, Georgina; Andrews, Gavin; Jones, David S; Hill, Andrew G; Svirskis, Darren
2017-09-01
An efficient and cost-effective quantification procedure for lidocaine by HPLC has been developed to estimate lidocaine from an EVA matrix, plasma, peritoneal fluid and intra-articular fluid (IAF). This method guarantees the resolution of lidocaine from the degradation products obtained from alkaline and oxidative stress. Chromatographic separation of lidocaine was achieved with a retention time of 7 min using a C18 column with a mobile phase comprising acetonitrile and potassium dihydrogen phosphate buffer (pH 5.5; 0.02 M) in the ratio of 26:74 at a flow rate of 1 mL min-1 with detection at 230 nm. Instability of lidocaine was observed to an oxidizing (0.02% H2O2) and alkaline environments (0.1 M NaOH). The calibration curve was found to be linear within the concentration range of 0.40-50.0 μg/mL. Intra-day and inter-day accuracy ranged between 95.9% and 99.1%, with precision (% RSD) below 6.70%. The limit of quantification and limit of detection were 0.40 μg/mL and 0.025 μg/mL, respectively. The simple extraction method described enabled the quantification of lidocaine from an EVA matrix using dichloromethane as a solvent. The assay and content uniformity of lidocaine within an EVA matrix were 103 ± 3.60% and 100 ± 2.60%, respectively. The ability of this method to quantify lidocaine release from EVA films was also demonstrated. Extraction of lidocaine from plasma, peritoneal fluid and IAF followed by HPLC analysis confirmed the utility of this method for ex vivo and in vivo studies where the calibration plot was found to be linear from 1.60 to 50.0 μg/mL. © Crown copyright 2017.
Zhang, Dan; Wang, Xiaolin; Liu, Man; Zhang, Lina; Deng, Ming; Liu, Huichen
2015-01-01
A rapid, sensitive and accurate ICP-MS method using alternate analyte-free matrix for calibration standards preparation and a rapid direct dilution procedure for sample preparation was developed and validated for the quantification of exogenous strontium (Sr) from the drug in human serum. Serum was prepared by direct dilution (1:29, v/v) in an acidic solution consisting of nitric acid (0.1%) and germanium (Ge) added as internal standard (IS), to obtain simple and high-throughput preparation procedure with minimized matrix effect, and good repeatability. ICP-MS analysis was performed using collision cell technology (CCT) mode. Alternate matrix method by using distilled water as an alternate analyte-free matrix for the preparation of calibration standards (CS) was used to avoid the influence of endogenous Sr in serum on the quantification. The method was validated in terms of selectivity, carry-over, matrix effects, lower limit of quantification (LLOQ), linearity, precision and accuracy, and stability. Instrumental linearity was verified in the range of 1.00-500ng/mL, corresponding to a concentration range of 0.0300-15.0μg/mL in 50μL sample of serum matrix and alternate matrix. Intra- and inter-day precision as relative standard deviation (RSD) were less than 8.0% and accuracy as relative error (RE) was within ±3.0%. The method allowed a high sample throughput, and was sensitive and accurate enough for a pilot bioequivalence study in healthy male Chinese subjects following single oral administration of two strontium ranelate formulations containing 2g strontium ranelate. Copyright © 2014 Elsevier GmbH. All rights reserved.
Wilkinson, John L; Swinden, Julian; Hooda, Peter S; Barker, James; Barton, Stephen
2016-09-01
An effective, specific and accurate method is presented for the quantification of 13 markers of anthropogenic contaminants in water using solid phase extraction (SPE) followed by high performance liquid chromatography (HPLC) tandem mass spectrometry (MS/MS). Validation was conducted according to the International Conference on Harmonisation (ICH) guidelines. Method recoveries ranged from 77 to 114% and limits of quantification between 0.75 and 4.91 ng/L. A study was undertaken to quantify the concentrations and loadings of the selected contaminants in 6 sewage treatment works (STW) effluent discharges as well as concentrations in 5 rain-driven street runoffs and field drainages. Detection frequencies in STW effluent ranged from 25% (ethinylestradiol) to 100% (benzoylecgonine, bisphenol-A (BPA), bisphenol-S (BPS) and diclofenac). Average concentrations of detected compounds in STW effluents ranged from 3.62 ng/L (ethinylestradiol) to 210 ng/L (BPA). Levels of perfluorinated compounds (PFCs) perfluorooctanoic acid (PFOA) and perfluorononanoic acid (PFNA) as well as the plasticiser BPA were found in street runoff at maximum levels of 1160 ng/L, 647 ng/L and 2405 ng/L respectively (8.52, 3.09 and 2.7 times more concentrated than maximum levels in STW effluents respectively). Rain-driven street runoff may have an effect on levels of PFCs and plasticisers in receiving rivers and should be further investigated. Together, this method with the 13 selected contaminants enables the quantification of various markers of anthropogenic pollutants: inter alia pharmaceuticals, illicit drugs and their metabolites from humans and improper disposal of drugs, while the plasticisers and perfluorinated compounds may also indicate contamination from industrial and transport activity (street runoff). Copyright © 2016 Elsevier Ltd. All rights reserved.
Cortéjade, A; Kiss, A; Cren, C; Vulliet, E; Buleté, A
2016-01-01
The aim of this study was to develop an analytical method and contribute to the assessment of the Exposome. Thus, a targeted analysis of a wide range of contaminants in contact with humans on daily routines in urine was developed. The method focused on a list of 38 contaminants, including 12 pesticides, one metabolite of pesticide, seven veterinary drugs, five parabens, one UV filter, one plastic additive, two surfactants and nine substances found in different products present in the everyday human environment. These contaminants were analyzed by high performance liquid chromatography coupled to high resolution mass spectrometry (HPLC-HRMS) with a quadrupole-time-of-flight (QqToF) instrument from a raw urinary matrix. A validation according to the FDA guidelines was employed to evaluate the specificity, linear or quadratic curve fitting, inter- and intra-day precision, accuracy and limits of detection and quantification (LOQ). The developed analysis allows for the quantification of 23 contaminants in the urine samples, with the LOQs ranging between 4.3 ng.mL(-1) and 113.2 ng.mL(-1). This method was applied to 17 urine samples. Among the targeted contaminants, four compounds were detected in samples. One of the contaminants (tributyl phosphate) was detected below the LOQ. The three others (4-hydroxybenzoic acid, sodium dodecylbenzenesulfonate and O,O-diethyl thiophosphate potassium) were detected but did not fulfill the validation criteria for quantification. Among these four compounds, two of them were found in all samples: tributyl phosphate and the surfactant sodium dodecylbenzenesulfonate. Copyright © 2015 Elsevier B.V. All rights reserved.
Guo, Panpan; Yan, Wenying; Han, Qingjie; Wang, Chunying; Zhang, Zijian
2015-04-01
A sensitive and selective high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry method has been developed and validated for the simultaneous determination of 25 active constituents, including 21 flavonoids and four phenolic acids in the total flavonoids extract from Herba Desmodii Styracifolii for the first time. Among the 25 compounds, seven compounds including caffeic acid, acacetin, genistein, genistin, diosmetin, diosmin and hesperidin were identified and quantified for the first time in Herba Desmodii Styracifolii. Chromatographic separation was accomplished on a ZORBAX SB-C18 (250 mm×4.6 mm, 5.0 μm) column using gradient elution of methanol and 0.1‰ acetic acid v/v at a flow rate of 1.0 mL/min. The identification and quantification of the analytes were achieved using negative electrospray ionization mass spectrometry in multiple-reaction monitoring mode. The method was fully validated in terms of limits of detection and quantification, linearity, precision and accuracy. The results indicated that the developed method is simple, rapid, specific and reliable. Furthermore, the developed method was successfully applied to quantify the 25 active components in six batches of total flavonoids extract from Herba Desmodii Styracifolii. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Sun, Qian; Chang, Lu; Ren, Yanping; Cao, Liang; Sun, Yingguang; Du, Yingfeng; Shi, Xiaowei; Wang, Qiao; Zhang, Lantong
2012-11-01
A novel method based on high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry was developed for simultaneous determination of the 11 major active components including ten flavonoids and one phenolic acid in Cirsium setosum. Separation was performed on a reversed-phase C(18) column with gradient elution of methanol and 0.1‰ acetic acid (v/v). The identification and quantification of the analytes were achieved on a hybrid quadrupole linear ion trap mass spectrometer. Multiple-reaction monitoring scanning was employed for quantification with switching electrospray ion source polarity between positive and negative modes in a single run. Full validation of the assay was carried out including linearity, precision, accuracy, stability, limits of detection and quantification. The results demonstrated that the method developed was reliable, rapid, and specific. The 25 batches of C. setosum samples from different sources were first determined using the developed method and the total contents of 11 analytes ranged from 1717.460 to 23028.258 μg/g. Among them, the content of linarin was highest, and its mean value was 7340.967 μg/g. Principal component analysis and hierarchical clustering analysis were performed to differentiate and classify the samples, which is helpful for comprehensive evaluation of the quality of C. setosum. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Wang, Yongqing; Zhang, Peipei; Jiang, Ningling; Gong, Xiaojian; Meng, Ling; Wang, Dewang; Ou, Ning; Zhang, Haibo
2012-06-15
The aim of this study was to develop a rapid and sensitive method for the simultaneous quantification of metronidazole (MEZ), tinidazole (TNZ), ornidazole (ONZ) and morinidazole (MNZ) in human saliva. A reversed-phase high-performance liquid chromatography (HPLC) method with ultraviolet (UV) detection at 318 nm was carried out on a C18 column, using a mixture of potassium dihydrogen phosphate buffer, acetonitrile, and methanol (55:15:30, v/v/v) as a mobile phase with a flow rate of 1.0 ml/min. The saliva samples (100 μl) were firstly deproteinized by precipitation with methanol (400 μl), after which they were centrifuged and the supernatants were directly injected into the HPLC system. This method produced linear responses in the concentration ranges of 25.2-5040.0, 23.9-4790.0, 25.4-5080.0, 25.0-5000.0 ng/ml with detection limits of 6.0, 17.6, 10.0 and 11.3 ng/ml for MEZ, TNZ, ONZ and MNZ (S/N=3), respectively. The methods were validated in terms of intra- and inter-batch precision (within 7.3% and 9.1%, respectively), accuracy, linearity, recovery and stability. The study proved that HPLC is both sensitive and selective for the simultaneous quantification of MEZ, TNZ, ONZ and MNZ in human saliva using a single mobile phase. Copyright © 2012 Elsevier B.V. All rights reserved.
Domènech, Albert; Cortés-Francisco, Nuria; Palacios, Oscar; Franco, José M; Riobó, Pilar; Llerena, José J; Vichi, Stefania; Caixach, Josep
2014-02-07
A multitoxin method has been developed for quantification and confirmation of lipophilic marine biotoxins in mussels by liquid chromatography coupled to high resolution mass spectrometry (HRMS), using an Orbitrap-Exactive HCD mass spectrometer. Okadaic acid (OA), yessotoxin, azaspiracid-1, gymnodimine, 13-desmethyl spirolide C, pectenotoxin-2 and Brevetoxin B were analyzed as representative compounds of each lipophilic toxin group. HRMS identification and confirmation criteria were established. Fragment and isotope ions and ion ratios were studied and evaluated for confirmation purpose. In depth characterization of full scan and fragmentation spectrum of the main toxins were carried out. Accuracy (trueness and precision), linearity, calibration curve check, limit of quantification (LOQ) and specificity were the parameters established for the method validation. The validation was performed at 0.5 times the current European Union permitted levels. The method performed very well for the parameters investigated. The trueness, expressed as recovery, ranged from 80% to 94%, the precision, expressed as intralaboratory reproducibility, ranged from 5% to 22% and the LOQs range from 0.9 to 4.8pg on column. Uncertainty of the method was also estimated for OA, using a certified reference material. A top-down approach considering two main contributions: those arising from the trueness studies and those coming from the precision's determination, was used. An overall expanded uncertainty of 38% was obtained. Copyright © 2014 Elsevier B.V. All rights reserved.
Cho, Jin-Young; Lee, Hyoung-Joo; Jeong, Seul-Ki; Paik, Young-Ki
2017-12-01
Mass spectrometry (MS) is a widely used proteome analysis tool for biomedical science. In an MS-based bottom-up proteomic approach to protein identification, sequence database (DB) searching has been routinely used because of its simplicity and convenience. However, searching a sequence DB with multiple variable modification options can increase processing time, false-positive errors in large and complicated MS data sets. Spectral library searching is an alternative solution, avoiding the limitations of sequence DB searching and allowing the detection of more peptides with high sensitivity. Unfortunately, this technique has less proteome coverage, resulting in limitations in the detection of novel and whole peptide sequences in biological samples. To solve these problems, we previously developed the "Combo-Spec Search" method, which uses manually multiple references and simulated spectral library searching to analyze whole proteomes in a biological sample. In this study, we have developed a new analytical interface tool called "Epsilon-Q" to enhance the functions of both the Combo-Spec Search method and label-free protein quantification. Epsilon-Q performs automatically multiple spectral library searching, class-specific false-discovery rate control, and result integration. It has a user-friendly graphical interface and demonstrates good performance in identifying and quantifying proteins by supporting standard MS data formats and spectrum-to-spectrum matching powered by SpectraST. Furthermore, when the Epsilon-Q interface is combined with the Combo-Spec search method, called the Epsilon-Q system, it shows a synergistic function by outperforming other sequence DB search engines for identifying and quantifying low-abundance proteins in biological samples. The Epsilon-Q system can be a versatile tool for comparative proteome analysis based on multiple spectral libraries and label-free quantification.
Choi, Sol Ji; Jung, Mun Yhung
2017-04-01
We have developed a simple and fast sample preparation technique in combination with a gas chromatography-tandem mass spectrometry (GC-MS/MS) for the quantification of 2-methylimidazole (2-MeI) and 4-methylimidazole (4-MeI) in colas and dark beers. Conventional sample preparation technique for GC-MS requires laborious and time-consuming steps consisting of sample concentration, pH adjustment, ion pair extraction, centrifugation, back-extraction, centrifugation, derivatization, and extraction. Our sample preparation technique consists of only 2 steps (in situ derivation and extraction) which requires less than 3 min. This method provided high linearity, low limit of detection and limit of quantification, high recovery, and high intra- and interday repeatability. It was found that internal standard method with diluted stable isotope (4-MeI-d 6 ) and 2-ethylimidazole (2-EI) could not correctly compensate the matrix effects. Thus, standard addition technique was used for the quantification of 2- and 4-MeI. The established method was successfully applied to colas and dark beers for the determination of 2-MeI and 4-MeI. The 4-MeI contents in colas and dark beers ranged from 8 to 319 μg/L and from trace to 417 μg/L, respectively. Small quantity (0 to 8 μg/L) of 2-MeI was found only in dark beers. The contents of 4-MeI (22 μg/L) in colas obtained from fast food restaurants were significantly lower than those (177 μg/L) in canned or bottled colas. © 2017 Institute of Food Technologists®.
LoC-SERS toward clinical application: quantification of antibiotics in human urine samples
NASA Astrophysics Data System (ADS)
Hidi, I. J.; Jahn, M.; Weber, K.; Pletz, M. W.; Bocklitz, T. W.; Cialla-May, D.; Popp, J.
2017-02-01
The determination of the concentration of xenobiotics in biological matrix followed by the change of the prescribing procedure plays a major role in the transition from general to personalized medicine. For this contribution, human urine samples collected from healthy volunteers and from patients having urinary tract infection were used as biological matrix to assess the potential and limitation of LoC-SERS to detected levofloxacin and nitroxoline. The determination of both antibiotics at clinically relevant concentrations, 1.38 mM +/- 0.68 mM for levofloxacin and 10-40 µM for nitroxoline, will be presented. For quantification purposes the standard addition method is combined with LoC-SERS.
2013-01-01
The formalin-fixed, paraffin-embedded (FFPE) biopsy is a challenging sample for molecular assays such as targeted next-generation sequencing (NGS). We compared three methods for FFPE DNA quantification, including a novel PCR assay (‘QFI-PCR’) that measures the absolute copy number of amplifiable DNA, across 165 residual clinical specimens. The results reveal the limitations of commonly used approaches, and demonstrate the value of an integrated workflow using QFI-PCR to improve the accuracy of NGS mutation detection and guide changes in input that can rescue low quality FFPE DNA. These findings address a growing need for improved quality measures in NGS-based patient testing. PMID:24001039
Karain, Wael I
2017-11-28
Proteins undergo conformational transitions over different time scales. These transitions are closely intertwined with the protein's function. Numerous standard techniques such as principal component analysis are used to detect these transitions in molecular dynamics simulations. In this work, we add a new method that has the ability to detect transitions in dynamics based on the recurrences in the dynamical system. It combines bootstrapping and recurrence quantification analysis. We start from the assumption that a protein has a "baseline" recurrence structure over a given period of time. Any statistically significant deviation from this recurrence structure, as inferred from complexity measures provided by recurrence quantification analysis, is considered a transition in the dynamics of the protein. We apply this technique to a 132 ns long molecular dynamics simulation of the β-Lactamase Inhibitory Protein BLIP. We are able to detect conformational transitions in the nanosecond range in the recurrence dynamics of the BLIP protein during the simulation. The results compare favorably to those extracted using the principal component analysis technique. The recurrence quantification analysis based bootstrap technique is able to detect transitions between different dynamics states for a protein over different time scales. It is not limited to linear dynamics regimes, and can be generalized to any time scale. It also has the potential to be used to cluster frames in molecular dynamics trajectories according to the nature of their recurrence dynamics. One shortcoming for this method is the need to have large enough time windows to insure good statistical quality for the recurrence complexity measures needed to detect the transitions.
Fluorogenic Ag+–Tetrazolate Aggregation Enables Efficient Fluorescent Biological Silver Staining
Xie, Sheng; Wong, Alex Y. H.; Kwok, Ryan T. K.; Li, Ying; Su, Huifang; Lam, Jacky W. Y.
2018-01-01
Abstract Silver staining, which exploits the special bioaffinity and the chromogenic reduction of silver ions, is an indispensable visualization method in biology. It is a most popular method for in‐gel protein detection. However, it is limited by run‐to‐run variability, background staining, inability for protein quantification, and limited compatibility with mass spectroscopic (MS) analysis; limitations that are largely attributed to the tricky chromogenic visualization. Herein, we reported a novel water‐soluble fluorogenic Ag+ probe, the sensing mechanism of which is based on an aggregation‐induced emission (AIE) process driven by tetrazolate‐Ag+ interactions. The fluorogenic sensing can substitute the chromogenic reaction, leading to a new fluorescence silver staining method. This new staining method offers sensitive detection of total proteins in polyacrylamide gels with a broad linear dynamic range and robust operations that rival the silver nitrate stain and the best fluorescent stains. PMID:29575702
Frew, John A.; Grue, Christian E.
2012-01-01
The neonicotinoid insecticide imidacloprid (IMI) has been proposed as an alternative to carbaryl for controlling indigenous burrowing shrimp on commercial oyster beds in Willapa Bay and Grays Harbor, Washington. A focus of concern over the use of this insecticide in an aquatic environment is the potential for adverse effects from exposure to non-target species residing in the Bay, such as juvenile Chinook (Oncorhynchus tshawytscha) and cutthroat trout (O. clarki). Federal registration and State permiting approval for the use of IMI will require confirmation that the compound does not adversely impact these salmonids following field applications. This will necessitate an environmental monitoring program for evaluating exposure in salmonids following the treatment of beds. Quantification of IMI residues in tissue can be used for determining salmonid exposure to the insecticide. Refinement of an existing protocol using liquid-chromatography mass spectrometry (LC-MS) detection would provide the low limits of quantification, given the relatively small tissue sample sizes, necessary for determining exposure in individual fish. Such an approach would not be viable for the environmental monitoring effort in Willapa Bay and Grays Harbor due to the high costs associated with running multiple analyses, however. A new sample preparation protocol was developed for use with a commercially available enzyme-linked immunosorbent assay (ELISA) for the quantification of IMI, thereby providing a low-cost alternative to LC-MS for environmental monitoring in Willapa Bay and Grays Harbor. Extraction of the analyte from the salmonid brain tissue was achieved by Dounce homogenization in 4.0 mL of 20.0 mM Triton X-100, followed by a 6 h incubation at 50–55 °C. Centrifugal ultrafiltration and reversed phase solid phase extraction were used for sample cleanup. The limit of quantification for an average 77.0 mg whole brain sample was calculated at 18.2 μg kg-1 (ppb) with an average recovery of 79%. This relatively low limit of quantification allows for the analysis of individual fish. Using controlled laboratory studies, a curvelinear relationship was found between the measured IMI residue concentrations in brain tissue and exposure concentrations in seawater. Additonally, a range of IMI brain residue concentrations was associated with an overt effect; illustrating the utility of the IMI tissue residue quantification approach for linking exposure with defined effects.
Drooger, Jan C; Jager, Agnes; Lam, Mei-Ho; den Boer, Mathilda D; Sleijfer, Stefan; Mathijssen, Ron H J; de Bruijn, Peter
2015-10-10
The aim of this study was to validate an earlier developed high-performance highly sensitive ultra performance liquid chromatography/tandem mass spectrometry (UPLC-MS/MS) method for quantification of tamoxifen and its three main metabolites (N-desmethyl-tamoxifen, 4-hydroxy-tamoxifen and 4-hydroxy-N-desmethyl-tamoxifen) in scalp hair. This non-invasive method might, by segmental analysis of hair, be useful in the determination of the concentration of drugs and its metabolites over time, which can be used to study a wide variety of clinical relevant questions. Hair samples (150-300 hair strands, cut as close to the scalp as possible from the posterior vertex region of the head) were collected from female patients taking tamoxifen 20mg daily (n=19). The analytes were extracted using a liquid-liquid extraction procedure with carbonate buffer at pH 8.8 and a mixture of n-hexane/isopropranol method, followed by UPLC-MS/MS chromatography, based on an earlier validated method. The calibration curves were linear in the range of 1.00-200 pmol for tamoxifen and N-desmethyl-tamoxifen, with lower limit of quantitation of 1.00 pmol and 0.100-20.0 pmol with lower limit of quantitation of 0.100 pmol for endoxifen and 4-hydroxy-tamoxifen. Assay performance was fair with a within-run and between-run variability less than 9.24 at the three quality control samples and less than 15.7 for the lower limit of quantitation. Importantly, a steep linear decline was observed from distal to proximal hair segments. Probably, this is due to UV exposure as we showed degradation of tamoxifen and its metabolites after exposure to UV-light. Furthermore, higher concentrations of tamoxifen were found in black hair samples compared to blond and brown hair samples. We conclude that measurement of the concentration of tamoxifen and its main metabolites in hair is possible, with the selective, sensitive, accurate and precise UPLC-MS/MS method. However, for tamoxifen, it seems not possible to determine exposure over time with segmental analysis of hair, probably largely due to the effect of UV irradiation. Further research should therefore focus on quantification of other anticancer drugs, in segmented scalp hair, that are less sensitive to UV irradiation. Copyright © 2015 Elsevier B.V. All rights reserved.
de la Calle, Maria B; Devesa, Vicenta; Fiamegos, Yiannis; Vélez, Dinoraz
2017-09-01
The European Food Safety Authority (EFSA) underlined in its Scientific Opinion on Arsenic in Food that in order to support a sound exposure assessment to inorganic arsenic through diet, information about distribution of arsenic species in various food types must be generated. A method, previously validated in a collaborative trial, has been applied to determine inorganic arsenic in a wide variety of food matrices, covering grains, mushrooms and food of marine origin (31 samples in total). The method is based on detection by flow injection-hydride generation-atomic absorption spectrometry of the iAs selectively extracted into chloroform after digestion of the proteins with concentrated HCl. The method is characterized by a limit of quantification of 10 µg/kg dry weight, which allowed quantification of inorganic arsenic in a large amount of food matrices. Information is provided about performance scores given to results obtained with this method and which were reported by different laboratories in several proficiency tests. The percentage of satisfactory results obtained with the discussed method is higher than that of the results obtained with other analytical approaches.
Li, Jin; Zhang, Qiu-Hong; He, Jun; Liu, Er-wei; Gao, Xiu-mei; Chang, Yan-xu
2015-01-01
An improved LC-MS/MS method was developed for simultaneous determination of eleven bioactive constituents of Radix Angelicae Pubescentis and its related preparations. It was the first report on the quantification of bioactive constituents in different preparations of Radix Angelicae Pubescentis by LC-MS/MS analytical method. These samples were separated with an Agilent Zorbax Extend reversed-phase C18 column (1.8 μm, 4.6 × 100 mm) by linear gradient elution using aqueous ammonium acetate and acetonitrile as mobile phase. The flow rate was 0.3 mL min−1. The eleven bioactive constituents showed good regression (R > 0.990) within test ranges and the recoveries were in the range of 87.1–110%. The limit of detections and quantifications for most of the major constituents were less than 0.5 and 1.0 ng mL−1, respectively. All results indicated that the developed method could be readily utilized as a suitable quality control method for Radix Angelicae Pubescentis and related preparations. PMID:26078992
Zacharis, Constantinos K; Vastardi, Elli
2018-02-20
In the research presented we report the development of a simple and robust liquid chromatographic method for the quantification of two genotoxic alkyl sulphonate impurities (namely methyl p-toluenesulfonate and isopropyl p-toluenesulfonate) in Aprepitant API substances using the Analytical Quality by Design (AQbD) approach. Following the steps of AQbD protocol, the selected critical method attributes (CMAs) were the separation criterions between the critical peak pairs, the analysis time and the peak efficiencies of the analytes. The critical method parameters (CMPs) included the flow rate, the gradient slope and the acetonitrile content at the first step of the gradient elution program. Multivariate experimental designs namely Plackett-Burman and Box-Behnken designs were conducted sequentially for factor screening and optimization of the method parameters. The optimal separation conditions were estimated using the desirability function. The method was fully validated in the range of 10-200% of the target concentration limit of the analytes using the "total error" approach. Accuracy profiles - a graphical decision making tool - were constructed using the results of the validation procedures. The β-expectation tolerance intervals did not exceed the acceptance criteria of±10%, meaning that 95% of future results will be included in the defined bias limits. The relative bias ranged between - 1.3-3.8% for both analytes, while the RSD values for repeatability and intermediate precision were less than 1.9% in all cases. The achieved limit of detection (LOD) and the limit of quantification (LOQ) were adequate for the specific purpose and found to be 0.02% (corresponding to 48μgg -1 in sample) for both methyl and isopropyl p-toluenesulfonate. As proof-of-concept, the validated method was successfully applied in the analysis of several Aprepitant batches indicating that this methodology could be used for routine quality control analyses. Copyright © 2017 Elsevier B.V. All rights reserved.
Sampaio, Francisco; Ladeiras-Lopes, Ricardo; Almeida, João; Fonseca, Paulo; Fontes-Carvalho, Ricardo; Ribeiro, José; Gama, Vasco
2017-07-01
Management of patients with mitral stenosis (MS) depends heavily on the accurate quantification of mitral valve area (MVA) using echocardiography. All currently used two-dimensional (2D) methods have limitations. Estimation of MVA using the proximal isovelocity surface area (PISA) method with real time three-dimensional (3D) echocardiography may circumvent those limitations. We aimed to evaluate the accuracy of 3D direct measurement of PISA in the estimation of MVA. Twenty-seven consecutive patients (median age of 63 years; 77.8% females) with rheumatic MS were prospectively studied. Transthoracic and transesophageal echocardiography with 2D and 3D acquisitions were performed on the same day. The reference method for MVA quantification was valve planimetry after 3D-volume multiplanar reconstruction. A semi-automated software was used to calculate the 3D flow convergence volume. Compared to MVA estimation using 3D planimetry, 3D PISA showed the best correlation (rho=0.78, P<.0001), followed by pressure half-time (PHT: rho=0.66, P<.001), continuity equation (CE: rho=0.61, P=.003), and 2D PISA (rho=0.26, P=.203). Bland-Altman analysis revealed a good agreement for MVA estimation with 3D PISA (mean difference -0.03 cm 2 ; limits of agreement (LOA) -0.40-0.35), in contrast to wider LOA for 2D methods: CE (mean difference 0.02 cm 2 , LOA -0.56-0.60); PHT (mean difference 0.31 cm 2 , LOA -0.32-0.95); 2D PISA (mean difference -0.03 cm 2 , LOA -0.92-0.86). MVA estimation using 3D PISA was feasible and more accurate than 2D methods. Its introduction in daily clinical practice seems possible and may overcome technical limitations of 2D methods. © 2017, Wiley Periodicals, Inc.
Colorimetric and fluorescent detection of hydrazine with high sensitivity and excellent selectivity
NASA Astrophysics Data System (ADS)
Shi, Bingjie; Qi, Sujie; Yu, Mingming; Liu, Chunxia; Li, Zhanxian; Wei, Liuhe; Ni, Zhonghai
2018-01-01
It is critical to develop probes for rapid, selective, and sensitive detection of the highly toxic hydrazine in both environmental and biological science. In this work, under mild condition, a novel colorimetric and off-on fluorescent probe was synthesized for rapid recognition of hydrazine with excellent selectivity over other various species including some biological species, metal ions and anions. The limit of quantification (LOQ) value was 1.5 × 10- 4 M-3.2 × 10- 3 M (colorimetric method) and 1.5 × 10- 4 M - 3.2 × 10- 3 M (fluorescent method) with as low as detection limit of 46.2 μM.
One-step liquid-liquid extraction of cocaine from urine samples for gas chromatographic analysis.
Farina, Marcelo; Yonamine, Maurício; Silva, Ovandir A
2002-07-17
An improved technique for cocaine extraction from urine samples for gas chromatographic (GC) analysis is described. Employing a simple liquid-liquid extraction (LLE) of cocaine with a mixture of ethyl ether:isopropanol (9:1) the method presents a mean recovery of 74.49%. Limit of detection (LOD) and limit of quantification (LOQ) were 5 and 20 ng/ml, respectively. The method is highly precise (coefficient of variation (CV) <8%) and linear from 20 to 2000 ng/ml. It can he applied to detect the presence of cocaine in urine as a marker of its recent use in drug abuse treatment protocols.
Morio, Florent; Corvec, Stéphane; Caroff, Nathalie; Le Gallou, Florence; Drugeon, Henri; Reynaud, Alain
2008-07-01
We developed a quantitative real-time PCR assay targeting the mip gene of Legionella pneumophila for a prospective study from September 2004 to April 2005. It was compared with a standard culture method (French guideline AFNOR T90-431), analysing 120 water samples collected to monitor the risk related to Legionellae at Nantes hospital and to investigate a case of legionellosis acquired from hospital environment. Samples from six distinct water distribution systems were analysed by DNA extraction, amplification and detection with specific primers and FRET probes. The detection limit was 100 genomic units of L. pneumophila per liter (GU/l), the positivity threshold about 600 GU/l and the quantification limit 800 GU/l. PCR results were divided into three groups: negative (n=63), positive but non-quantifiable (n=22) or positive (n=35). PCR showed higher sensitivity than culture, whereas four culture-positive samples appeared negative by PCR (PCR inhibitor detected for two of them). Although no correlation was observed between both methods and real-time PCR cannot substitute for the reference method, it represents an interesting complement. Its sensitivity, reproducibility and rapidity appear particularly interesting in epidemic contexts in order to identify the source of contamination or to evaluate critical points of contamination in water distribution systems.
Liu, Hao-Long; Luo, Rong; Chen, Xiao-Qing; Ba, Yin-Ying; Zheng, Li; Guo, Wei-Wei; Wu, Xia
2015-06-15
A simple, effective and suitable UFLC-ESI-MS/MS method was firstly developed to simultaneously determine five characteristic constituents (piperine, piperlonguminine, Δα,β-dihydropiperlonguminine, pellitorine and piperanine) of Piper longum L. The total alkaloids of P. longum L. was prepared. The alkaloid contents of Piper nigrum L. and P. longum L. were compared. The analysis was carried out in multiple reaction monitoring scan mode. The method showed a good specificity, linearity (R(2)>0.995), stability (RSD<2.53%), repeatability (RSD<2.58%), and recovery (90.0-103.5%). The limits of detection and limits of quantification of five alkaloids were in the range of 0.02-0.03 and 0.05-0.10 ng/mL, respectively. The intra- and inter-day precision was less than 9.30% and 9.55%, respectively. The validation results confirmed that the method could simultaneously determine the target alkaloids in the sample. Furthermore, the identities of the alkaloids were verified by HPLC-ESI-MS/MS. Compared with P. nigrum, P. longum had lower piperine content but was enriched in the other four alkaloids. Copyright © 2015 Elsevier Ltd. All rights reserved.
Zhang, Cheng; Nestorova, Gergana; Rissman, Robert A.; Feng, June
2013-01-01
8-Hydroxy-2′-deoxyguanosine (8-OHdG) is one of the major forms of oxidative deoxyribonucleic acid (DNA) damage, and is commonly analyzed as an excellent marker of DNA lesions. The purpose of this study was to develop a sensitive method to accurately and rapidly quantify the 8-OHdG by using capillary electrophoresis with laser-induced fluorescence detection (CE-LIF). The method involved the use of specific antibody to detect DNA lesions (8-OHdG) and consecutive fluorescence labeling. Next, the urine sample with 8-OHdG fluorescently labeled along with other constituents was resolved by capillary electrophoretic system and the lesion of interest was detected using fluorescence detector. The limit of detection was 0.18 fmol, which is sufficient sensitivity for detection and quantification of 8-OHdG in untreated urine samples. The relative standard deviation (RSD) was found to be 11.32 % for migration time, and 5.52 % for peak area. To demonstrate the utility of this method, the urinary concentration of 8-OHdG in an Alzheimer’s transgenic mouse model was determined. Collectively, our results indicate that this methodology offers great advantages such as high separation efficiency, good selectivity, low limit of detection (LOD), simplicity and low cost of analysis. PMID:23712533
Shi, Rui; Yan, Lihong; Xu, Tongguang; Liu, Dongye; Zhu, Yongfa; Zhou, Jun
2015-01-02
Polycyclic aromatic hydrocarbons (PAHs) were considered as a source of carcinogenicity in mainstream cigarette smoke (MSS). Accurate quantification of these components was necessary for assessing public health risk. In our study, a solid-phase extraction (SPE) method using graphene oxide (GO) bound silica as adsorbent for purification of 14 PAHs in MSS was developed. During SPE process, large matrices interferences of MSS were adsorbed on SPE column. The result of FTIR spectra demonstrated that these matrices interferences were adsorbed on GO mainly through OH and CO groups. The concentrations of PAHs in MSS extract were determined by gas chromatography-mass spectrometry (GC-MS). The limit of detection (LOD) and limit of quantification (LOQ) of the developed method for 14 PAHs ranged from 0.05 to 0.36 ng/cig and 0.17 to 1.19 ng/cig, respectively. The accuracy of the measurement of 14 PAHs was from 73 to 116%. The relative standard deviations of intra- and inter-day analysis were less than 7.8% and 13.9%, respectively. Moreover, the developed method was successfully applied for analysis of real cigarette containing 1R5F reference cigarette and 12 top-selling commercial cigarettes in China. Copyright © 2014 Elsevier B.V. All rights reserved.
Li, P; Jia, J W; Jiang, L X; Zhu, H; Bai, L; Wang, J B; Tang, X M; Pan, A H
2012-04-27
To ensure the implementation of genetically modified organism (GMO)-labeling regulations, an event-specific detection method was developed based on the junction sequence of an exogenous integrant in the transgenic carnation variety Moonlite. The 5'-transgene integration sequence was isolated by thermal asymmetric interlaced PCR. Based upon the 5'-transgene integration sequence, the event-specific primers and TaqMan probe were designed to amplify the fragments, which spanned the exogenous DNA and carnation genomic DNA. Qualitative and quantitative PCR assays were developed employing the designed primers and probe. The detection limit of the qualitative PCR assay was 0.05% for Moonlite in 100 ng total carnation genomic DNA, corresponding to about 79 copies of the carnation haploid genome; the limit of detection and quantification of the quantitative PCR assay were estimated to be 38 and 190 copies of haploid carnation genomic DNA, respectively. Carnation samples with different contents of genetically modified components were quantified and the bias between the observed and true values of three samples were lower than the acceptance criterion (<25%) of the GMO detection method. These results indicated that these event-specific methods would be useful for the identification and quantification of the GMO carnation Moonlite.
Musharraf, Syed Ghulam; Ul Arfeen, Qamar; Ul Haq, Faraz; Khatoon, Aliya; Azher Ali, Rahat
2017-10-01
Methyltestosterone is a synthetic testosterone derivative commonly used for the treatment of testosterone deficiency in males and one the anabolic steroids whose use is banned by World Anti-Doping Agency (WADA). This study presents a simple, cost-effective and rapid stability-indicating assay for densitometric quantification of methyltestosterone in pharmaceutical formulation. The developed method employed pre-coated TLC plates with mobile phase hexane:acetone (6.5:3.5 v/v). Limit of detection and limit of quantitation were found to be 2.06 and 6.24 ng/spot, respectively. Stress degradation study of methyltestosterone was conducted by applying various stress conditions such as hydrolysis under acidic, basic and neutral conditions, heating in anhydrous conditions and exposure to light. Methyltestosterone was found to be susceptible to photodegradation, acidic and basic hydrolysis. Degraded products were well resolved with significantly different Rf values. Acid degraded product was identified as 17,17-dimethyl-18-norandrosta-4,13(14)-dien-3-one through spectroscopic methods. The reactivity of methyltestosterone under applied stress conditions was also explained by quantum chemical calculations. The developed method is found to be repeatable, selective and accurate for quantification of methyltestosterone and can be employed for routine analysis. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Alam, Prawez
2013-01-01
Objective To develop and validate a simple, accurate HPTLC method for the analysis of 8-gingerol and to determine the quantity of 8-gingerol in Zingiber officinale extract and ginger-containing dietary supplements, teas and commercial creams. Methods The analysis was performed on 10×20 cm aluminium-backed plates coated with 0.2 mm layers of silica gel 60 F254 (E-Merck, Germany) with n-hexane: ethyl acetate 60: 40 (v/v) as mobile phase. Camag TLC Scanner III was used for the UV densitometric scanning at 569. Results This system was found to give a compact spot of 8-gingerol at retention factor (Rf) value of (0.39±0.04) and linearity was found in the ranges 50-500 ng/spot (r2=0.9987). Limit of detection (12.76 ng/spot), limit of quantification (26.32 ng/spot), accuracy (less than 2 %) and recovery (ranging from 98.22-99.20) were found satisfactory. Conclusions The HPTLC method developed for quantification of 8-gingerol was found to be simple, accurate, reproducible, sensitive and is applicable to the analysis of 8-gingerol in Zingiber officinale extract and ginger-containing dietary supplements, teas and commercial creams. PMID:23905021
Gupta, Abhishek; Singh, Yogendra; Srinivas, Kona S.; Jain, Garima; Sreekumar, V. B.; Semwal, Vinod Prasad
2010-01-01
Objective: Arterolane maleate is an antimalarial drug currently under Phase III clinical evaluation, and presents a simple, economical and scalable synthesis, and does not suffer from safety problems. Arterolane maleate is more active than artemisinin; and is cheap to produce. It has a longer lifetime in the plasma, so it stays active longer in the body. To provide quality control over the manufacture of any API, it is essential to develop highly selective analytical methods. In the current article we are reporting the development and validation of a rapid and specific Head space gas chromatographic (HSGC) method for the determination of organic volatile impurities (residual solvents) in Arterolane Maleate bulk drug. Materials and Methods: The method development and its validation were performed on Perkin Elmer's gas chromatographic system equipped with Flame Ionization detector and head space analyzer. The method involved a thermal gradient elution of ten residual solvents present in arterolane maleate salt in RTx-624, 30 m × 0.32 mm, 1.8 μ column using nitrogen gas as a carrier. The flow rate was 0.5 ml/min and flame ionization detector (FID) was used. Results: During method validation, parameters such as precision, linearity, accuracy, limit of quantification and detection and specificity were evaluated, which remained within acceptable limits. Conclusions: The method has been successfully applied for the quantification of the amount of residual solvents present in arterolane maleate bulk drug.The method presents a simple and reliable solution for the routine quantitative analysis of residual solvents in Arterolane maleate bulk drug. PMID:21814428
Wang, Zhonghe; Yu, Jing; Yao, Jiaxi; Wu, Linlin; Xiao, Hang; Wang, Jun; Gao, Rong
2018-02-10
A method for the identification and quantification of bisphenol A and 12 bisphenol analogues in river water and sediment samples combining liquid-liquid extraction, precolumn derivatization, and ultra high-performance liquid chromatography coupled with tandem mass spectrometry was developed and validated. Analytes were extracted from the river water sample using a liquid-liquid extraction method. Dansyl chloride was selected as a derivatization reagent. Derivatization reaction conditions affecting production of the dansyl derivatives were tested and optimized. All the derivatized target compounds were well separated and eluted in 10 min. Dansyl chloride labeled compounds were analyzed using a high-resolution mass spectrometer with electrospray ionization in the positive mode, and the results were confirmed and quantified in the parallel reaction monitoring mode. The method validation results showed a satisfactory level of sensitivity. Linearity was assessed using matrix-matched standard calibration, and good correlation coefficients were obtained. The limits of quantification for the analytes ranged from 0.005 to 0.02 ng/mL in river water and from 0.15 to 0.80 ng/g in sediment. Good reproducibility of the method in terms of intra- and interday precision was achieved, yielding relative standard deviations of less than 10.1 and 11.6%, respectively. Finally, this method was successfully applied to the analysis of real samples. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Technical Reports Server (NTRS)
Sitges, Marta; Jones, Michael; Shiota, Takahiro; Qin, Jian Xin; Tsujino, Hiroyuki; Bauer, Fabrice; Kim, Yong Jin; Agler, Deborah A.; Cardon, Lisa A.; Zetts, Arthur D.;
2003-01-01
BACKGROUND: Pitfalls of the flow convergence (FC) method, including 2-dimensional imaging of the 3-dimensional (3D) geometry of the FC surface, can lead to erroneous quantification of mitral regurgitation (MR). This limitation may be mitigated by the use of real-time 3D color Doppler echocardiography (CE). Our objective was to validate a real-time 3D navigation method for MR quantification. METHODS: In 12 sheep with surgically induced chronic MR, 37 different hemodynamic conditions were studied with real-time 3DCE. Using real-time 3D navigation, the radius of the largest hemispherical FC zone was located and measured. MR volume was quantified according to the FC method after observing the shape of FC in 3D space. Aortic and mitral electromagnetic flow probes and meters were balanced against each other to determine reference MR volume. As an initial clinical application study, 22 patients with chronic MR were also studied with this real-time 3DCE-FC method. Left ventricular (LV) outflow tract automated cardiac flow measurement (Toshiba Corp, Tokyo, Japan) and real-time 3D LV stroke volume were used to quantify the reference MR volume (MR volume = 3DLV stroke volume - automated cardiac flow measurement). RESULTS: In the sheep model, a good correlation and agreement was seen between MR volume by real-time 3DCE and electromagnetic (y = 0.77x + 1.48, r = 0.87, P <.001, delta = -0.91 +/- 2.65 mL). In patients, real-time 3DCE-derived MR volume also showed a good correlation and agreement with the reference method (y = 0.89x - 0.38, r = 0.93, P <.001, delta = -4.8 +/- 7.6 mL). CONCLUSIONS: real-time 3DCE can capture the entire FC image, permitting geometrical recognition of the FC zone geometry and reliable MR quantification.
Almeida, M P; Rezende, C P; Souza, L F; Brito, R B
2012-01-01
The use of aminoglycoside antibiotics in food animals is approved in Brazil. Accordingly, Brazilian food safety legislation sets maximum levels for these drugs in tissues from these animals in an effort to guarantee that food safety is not compromised. Aiming to monitor the levels of these drugs in tissues from food animals, the validation of a quantitative, confirmatory method for the detection of residues of 10 aminoglycosides antibiotics in poultry, swine, equine and bovine kidney, with extraction using a solid phase and detection and quantification by LC-MS/MS was performed. The procedure is an adaptation of the US Department of Agriculture, Food Safety and Inspection Service (USDA-FSIS) qualitative method, with the inclusion of additional clean-up and quantification at lower levels, which proved more efficient. Extraction was performed using a phosphate buffer containing trifluoroacetic acid followed by neutralization, purification on a cationic exchange SPE cartridge, with elution with methanol/acetic acid, evaporation, and dilution in ion-pair solvent. The method was validated according to the criteria and requirements of the European Commission Decision 2002/657/EC, showing selectivity with no matrix interference. Linearity was established for all analytes using the method of weighted minimum squares. CCα and CCβ varied between 1036 and 12,293 µg kg(-1), and between 1073 and 14,588 µg kg(-1), respectively. The limits of quantification varied between 27 and 688 µg kg(-1). The values of recovery for all analytes in poultry kidney, fortified in the range of 500-1500 µg kg(-1), were higher than 90%, and the relative standard deviations were lower than 15%, except spectinomycin (21.8%). Uncertainty was estimated using a simplified methodology of 'bottom-up' and 'top-down' strategies. The results showed that this method is effective for the quantification and confirmation of aminoglycoside residues and could be used by the Brazilian programme of residue control.
Takabatake, Reona; Masubuchi, Tomoko; Futo, Satoshi; Minegishi, Yasutaka; Noguchi, Akio; Kondo, Kazunari; Teshima, Reiko; Kurashima, Takeyo; Mano, Junichi; Kitta, Kazumi
2016-01-01
A novel real-time PCR-based analytical method was developed for the event-specific quantification of a genetically modified (GM) maize, 3272. We first attempted to obtain genome DNA from this maize using a DNeasy Plant Maxi kit and a DNeasy Plant Mini kit, which have been widely utilized in our previous studies, but DNA extraction yields from 3272 were markedly lower than those from non-GM maize seeds. However, lowering of DNA extraction yields was not observed with GM quicker or Genomic-tip 20/G. We chose GM quicker for evaluation of the quantitative method. We prepared a standard plasmid for 3272 quantification. The conversion factor (Cf), which is required to calculate the amount of a genetically modified organism (GMO), was experimentally determined for two real-time PCR instruments, the Applied Biosystems 7900HT (the ABI 7900) and the Applied Biosystems 7500 (the ABI7500). The determined Cf values were 0.60 and 0.59 for the ABI 7900 and the ABI 7500, respectively. To evaluate the developed method, a blind test was conducted as part of an interlaboratory study. The trueness and precision were evaluated as the bias and reproducibility of the relative standard deviation (RSDr). The determined values were similar to those in our previous validation studies. The limit of quantitation for the method was estimated to be 0.5% or less, and we concluded that the developed method would be suitable and practical for detection and quantification of 3272.
Vecchione, Gennaro; Casetta, Bruno; Chiapparino, Antonella; Bertolino, Alessandro; Tomaiuolo, Michela; Cappucci, Filomena; Gatta, Raffaella; Margaglione, Maurizio; Grandone, Elvira
2012-01-01
A simple liquid chromatographic tandem mass spectrometry (LC-MS/MS) method has been developed for simultaneous analysis of 17 basic and one acid psychotropic drugs in human plasma. The method relies on a protein precipitation step for sample preparation and offers high sensitivity, wide linearity without interferences from endogenous matrix components. Chromatography was run on a reversed-phase column with an acetonitrile-H₂O mixture. The quantification of target compounds was performed in multiple reaction monitoring (MRM) and by switching the ionization polarity within the analytical run. A further sensitivity increase was obtained by implementing the functionality "scheduled multiple reaction monitoring" (sMRM) offered by the recent version of the software package managing the instrument. The overall injection interval was less than 5.5 min. Regression coefficients of the calibration curves and limits of quantification (LOQ) showed a good coverage of over-therapeutic, therapeutic and sub-therapeutic ranges. Recovery rates, measured as percentage of recovery of spiked plasma samples, were ≥ 94%. Precision and accuracy data have been satisfactory for a therapeutic drug monitoring (TDM) service as for managing plasma samples from patients receiving psycho-pharmacological treatment. Copyright © 2012 Elsevier B.V. All rights reserved.
Lee, Ji Sang; Chung, Yoon-Sok; Chang, Sun Young
2017-01-01
Pentosidine is an advanced glycation end-product (AGE) and fluorescent cross-link compound. A simple high-performance liquid chromatographic (HPLC) method was developed for the detection and quantification of pentosidine in human urine and plasma. The mobile phase used a gradient system to improve separation of pentosidine from endogenous peaks, and chromatograms were monitored by fluorescent detector set at excitation and emission wavelengths of 328 and 378 nm, respectively. The retention time for pentosidine was 24.3 min and the lower limits of quantification (LLOQ) in human urine and plasma were 1 nM. The intraday assay precisions (coefficients of variation) were generally low and found to be in the range of 5.19–7.49% and 4.96–8.78% for human urine and plasma, respectively. The corresponding values of the interday assay precisions were 9.45% and 4.27%. Accuracies (relative errors) ranged from 87.9% to 115%. Pentosidine was stable in a range of pH solutions, human urine, and plasma. In summary, this HPLC method can be applied in future preclinical and clinical evaluation of pentosidine in the diabetic patients. PMID:29181026
NASA Astrophysics Data System (ADS)
Kim, Chang-Beom; Kim, Kwan-Soo; Song, Ki-Bong
2013-05-01
The importance of early Alzheimer's disease (AD) detection has been recognized to diagnose people at high risk of AD. The existence of intra/extracellular beta-amyloid (Aβ) of brain neurons has been regarded as the most archetypal hallmark of AD. The existing computed-image-based neuroimaging tools have limitations on accurate quantification of nanoscale Aβ peptides due to optical diffraction during imaging processes. Therefore, we propose a new method that is capable of evaluating a small amount of Aβ peptides by using photo-sensitive field-effect transistor (p-FET) integrated with magnetic force-based microbead collecting platform and selenium(Se) layer (thickness ~700 nm) as an optical filter. This method demonstrates a facile approach for the analysis of Aβ quantification using magnetic force and magnetic silica microparticles (diameter 0.2~0.3 μm). The microbead collecting platform mainly consists of the p-FET sensing array and the magnet (diameter ~1 mm) which are placed beneath each sensing region of the p-FET, which enables the assembly of the Aβ antibody conjugated microbeads, captures the Aβ peptides from samples, measures the photocurrents generated by the Q-dot tagged with Aβ peptides, and consequently results in the effective Aβ quantification.
A Pragmatic Smoothing Method for Improving the Quality of the Results in Atomic Spectroscopy
NASA Astrophysics Data System (ADS)
Bennun, Leonardo
2017-07-01
A new smoothing method for the improvement on the identification and quantification of spectral functions based on the previous knowledge of the signals that are expected to be quantified, is presented. These signals are used as weighted coefficients in the smoothing algorithm. This smoothing method was conceived to be applied in atomic and nuclear spectroscopies preferably to these techniques where net counts are proportional to acquisition time, such as particle induced X-ray emission (PIXE) and other X-ray fluorescence spectroscopic methods, etc. This algorithm, when properly applied, does not distort the form nor the intensity of the signal, so it is well suited for all kind of spectroscopic techniques. This method is extremely effective at reducing high-frequency noise in the signal much more efficient than a single rectangular smooth of the same width. As all of smoothing techniques, the proposed method improves the precision of the results, but in this case we found also a systematic improvement on the accuracy of the results. We still have to evaluate the improvement on the quality of the results when this method is applied over real experimental results. We expect better characterization of the net area quantification of the peaks, and smaller Detection and Quantification Limits. We have applied this method to signals that obey Poisson statistics, but with the same ideas and criteria, it could be applied to time series. In a general case, when this algorithm is applied over experimental results, also it would be required that the sought characteristic functions, required for this weighted smoothing method, should be obtained from a system with strong stability. If the sought signals are not perfectly clean, this method should be carefully applied
Gobo, Luciana Assis; de Carvalho, Leandro Machado; Temp, Fernanda; Viana, Carine; Mello, Carlos Fernando
2018-03-15
An analytical method utilizing liquid chromatography coupled to mass spectrometry with electrospray ionization has been developed for the identification of prostaglandins (PGs) in cerebral tissues. The five compounds identified (thromboxane B2, prostaglandin E2, prostaglandin D2, 6-keto-prostaglandin F1 alpha and prostaglandin F2 alpha) are cellular mediators of inflammation and are involved in a variety of physiological and pathological processes by acting on membrane receptors on the surfaces of target cells. The parameters of the electrospray ionization interface were optimized to obtain the highest possible sensitivity for all compounds studied. The limits of detection ranged from 0.25 to 1.09 μg L -1 , and the limits of quantification ranged from 0.83 to 3.64 μg L -1 . The method was validated and applied to samples of brain tissue from five mice. The sample concentrations of the four prostaglandins quantified ranged from 375 ȵg L -1 for prostaglandin E2 to 6602 μg L -1 for prostaglandin D2. An advantage of this work that should be emphasized is the fast response of the method, which allows to obtaining the lipid profile after a 3 min chromatographic run. Copyright © 2018 Elsevier Inc. All rights reserved.
Pano-Farias, Norma S; Ceballos-Magaña, Silvia G; Gonzalez, Jorge; Jurado, José M; Muñiz-Valencia, Roberto
2015-04-01
To improve the analysis of pesticides in complex food matrices with economic importance, alternative chromatographic techniques, such as supercritical fluid chromatography, can be used. Supercritical fluid chromatography has barely been applied for pesticide analysis in food matrices. In this paper, an analytical method using supercritical fluid chromatography coupled to a photodiode array detection has been established for the first time for the quantification of pesticides in papaya and avocado. The extraction of methyl parathion, atrazine, ametryn, carbofuran, and carbaryl was performed through the quick, easy, cheap, effective, rugged, and safe methodology. The method was validated using papaya and avocado samples. For papaya, the correlation coefficient values were higher than 0.99; limits of detection and quantification ranged from 130-380 and 220-640 μg/kg, respectively; recovery values ranged from 72.8-94.6%; precision was lower than 3%. For avocado, limit of detection values were ˂450 μg/kg; precision was lower than 11%; recoveries ranged from 50.0-94.2%. Method feasibility was tested for lime, banana, mango, and melon samples. Our results demonstrate that the proposed method is applicable to methyl parathion, atrazine, ametryn, and carbaryl, toxics pesticides used worldwide. The methodology presented in this work could be applicable to other fruits. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Li, J.S.; Chen, M.; Li, Z.C.
2012-01-01
A sensitive and reliable method of liquid chromatography–electrospray ionization/tandem mass spectrometry (LC-ESI/MS/ MS) was developed and validated for determining 1,3-dimethylamylamine (1,3-DMAA) and 1,4-dimethylamylamine (1,4-DMAA) in geranium plants (Pelargonium graveolens). The sample was extracted with 0.5 M HCl and purified by liquid-liquid partition with hexane. The parameters for reverse-phase (C18) LC and positive ESI/MS/MS were optimized. The matrix effect, specificity, linearity, precision, accuracy and reproducibility of the method were determined and evaluated. The method was linear over a range of 0.10–10.00 ng/mL examined, with R2 of 0.99 for both 1,3-DMAA and 1,4-DMAA. The recoveries from spiked concentrations between 5.00–40.00 ng/g were 85.1%–104.9% for 1,3-DMAA, with relative standard deviation (RSD) of 2.9%–11.0%, and 82.9%–101.8% for 1,4-DMAA, with RSD of 3.2%–11.7%. The instrument detection limit was 1–2 pg for both DMAAs. The quantification limit was estimated to be 1–2 ng/g for the plant sample. This method was successfully applied to the quantitative determination of 1,3- and 1,4-DMAA in both geranium plant and geranium oil. PMID:22915838
Brundu, Serena; Nencioni, Lucia; Celestino, Ignacio; Coluccio, Paolo; Palamara, Anna Teresa; Fraternale, Alessandra
2016-01-01
A depletion of reduced glutathione (GSH) has been observed in pathological conditions and in aging. Measuring GSH in tissues using mouse models is an excellent way to assess GSH depletion and the potential therapeutic efficacy of drugs used to maintain and/or restore cellular redox potential. A high performance liquid chromatography (HPLC) method for the simultaneous determination of GSH and cysteine (Cys) in mouse organs was validated according to USA and European standards. The method was based on separation coupled with ultraviolet detection and precolumn derivatization with 5,5′-dithiobis-(2-nitrobenzoic acid) (DTNB). The required validation parameters, that are, selectivity, linearity, lower limit of quantification, precision, accuracy, recovery, and stability, were studied for spleen, lymph nodes, pancreas, and brain. The results showed that the lower limits of quantification were 0.313 μM and 1.25 μM for Cys and GSH, respectively. Intraday and interday precisions were less than 11% and 14%, respectively, for both compounds. The mean extraction recoveries of Cys and GSH from all organs were more than 93% and 86%, respectively. Moreover, the stability of both analytes during sample preparation and storage was demonstrated. The method was accurate, reliable, consistent, and reproducible and it was useful to determine Cys and GSH in the organs of different mouse strains. PMID:26885246
Font, Guillermina; Juan-García, Ana; Picó, Yolanda
2007-08-03
A new analytical method, based on capillary electrophoresis and tandem mass spectrometry (CE-MS2), is proposed and validated for the identification and simultaneous quantification of 12 sulfonamides (SAs) in pork meat. The studied SAs include sulfathiazole, sulfadiazine, sulfamethoxypyridazine, sulfaguanidine, sulfanilamide, sulfadimethoxyne, sulfapyridine, sulfachloropyridazine, sulfisoxazole, sulfasalazine, sulfabenzamide and sulfadimidine. Different parameters (i.e. separation buffer, sheath liquid, electrospray conditions) were optimized to obtain an adequate CE separation and high MS sensitivity. MS2 experiments using an ion trap as analyzer, operating in the selected reaction monitoring (SRM) mode, were carried out to achieve the required number of identification points according to the 2002/657/EC European Decision. For the quantification in pork tissue samples, a pressurized liquid extraction (PLE) procedure, using hot water as extractant followed by an Oasis HLB cleanup, was developed. Linearity (r between 0.996 and 0.997), precision (RSD<14 %) and recoveries (from 76 to 98%) were satisfactory. The limits of detection and quantification (below 12.5 and 46.5 microg kg(-1), respectively) were in all cases lower than the maximum residue limits (MRLs), indicating the potential of CE-MS2 for the analysis of SAs, in the food quality and safety control areas.
Simple and clean determination of tetracyclines by flow injection analysis
NASA Astrophysics Data System (ADS)
Rodríguez, Michael Pérez; Pezza, Helena Redigolo; Pezza, Leonardo
2016-01-01
An environmentally reliable analytical methodology was developed for direct quantification of tetracycline (TC) and oxytetracycline (OTC) using continuous flow injection analysis with spectrophotometric detection. The method is based on the diazo coupling reaction between the tetracyclines and diazotized sulfanilic acid in a basic medium, resulting in the formation of an intense orange azo compound that presents maximum absorption at 434 nm. Experimental design was used to optimize the analytical conditions. The proposed technique was validated over the concentration range of 1 to 40 μg mL- 1, and was successfully applied to samples of commercial veterinary pharmaceuticals. The detection (LOD) and quantification (LOQ) limits were 0.40 and 1.35 μg mL- 1, respectively. The samples were also analyzed by an HPLC method, and the results showed agreement with the proposed technique. The new flow injection method can be immediately used for quality control purposes in the pharmaceutical industry, facilitating monitoring in real time during the production processes of tetracycline formulations for veterinary use.
Dolder, Patrick C; Liechti, Matthias E; Rentsch, Katharina M
2018-02-01
Lysergic acid diethylamide (LSD) is a widely used recreational drug. The aim of this study was to develop and validate a liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the quantification of LSD, iso-LSD, 2-oxo-3-hydroxy LSD (O-H-LSD), and nor-LSD in plasma samples from 24 healthy subjects after controlled administration of 100 μg LSD in a clinical trial. In addition, metabolites that have been recently described in in vitro studies, including lysergic acid monoethylamide (LAE), lysergic acid ethyl-2-hydroxyethylamide (LEO), 2-oxo-LSD, trioxylated-LSD, and 13/14-hydroxy-LSD, should be identified. Separation of LSD and its metabolites was achieved on a reversed phase chromatography column after turbulent-flow online extraction. For the identification and quantification, a triple-stage quadrupole LC-MS/MS instrument was used. The validation data showed slight matrix effects for LSD, iso-LSD, O-H-LSD, or nor-LSD. Mean intraday and interday accuracy and precision were 105%/4.81% and 105%/4.35% for LSD, 98.7%/5.75% and 99.4%/7.21% for iso-LSD, 106%/4.54% and 99.4%/7.21% for O-H-LSD, and 107%/5.82% and 102%/5.88% for nor-LSD, respectively. The limit of quantification was 0.05 ng/mL for LSD, iso-LSD, and nor-LSD and 0.1 ng/mL for O-H-LSD. The limit of detection was 0.01 ng/mL for all compounds. The method described herein was accurate, precise, and the calibration range within the range of expected plasma concentrations. LSD was quantified in the plasma samples of the 24 subjects of the clinical trial, whereas iso-LSD, O-H-LSD, nor-LSD, LAE, LEO, 13/14-hydroxy-LSD, and 2-oxo-LSD could only sporadically be detected but were too low for quantification. © 2017 Wiley Periodicals, Inc.
An enzymatic fluorescent assay for the quantification of phosphite in a microtiter plate format.
Berkowitz, Oliver; Jost, Ricarda; Pearse, Stuart J; Lambers, Hans; Finnegan, Patrick M; Hardy, Giles E St J; O'Brien, Philip A
2011-05-01
A sensitive fluorometric assay for the quantification of phosphite has been developed. The assay uses the enzymatic oxidation of phosphite to phosphate by a recombinant phosphite dehydrogenase with NAD(+) as cosubstrate to produce the highly fluorescent reaction product resorufin. The optimized assay can be carried out in a 96-well microtiter plate format for high-throughput screening purposes and has a detection limit of 0.25 nmol phosphite. We used the method to quantify phosphite levels in plant tissue extracts and to determine phosphite dehydrogenase activity in transgenic plants. The assay is suitable for other biological or environmental samples. Because phosphite is a widely used fungicide to protect plants from pathogenic oomycetes, the assay provides a cost-effective and easy-to-use method to monitor the fate of phosphite following application. Copyright © 2011 Elsevier Inc. All rights reserved.
2012-01-01
Multiple reaction monitoring mass spectrometry (MRM-MS) with stable isotope dilution (SID) is increasingly becoming a widely accepted assay for the quantification of proteins and peptides. These assays have shown great promise in relatively high throughput verification of candidate biomarkers. While the use of MRM-MS assays is well established in the small molecule realm, their introduction and use in proteomics is relatively recent. As such, statistical and computational methods for the analysis of MRM-MS data from proteins and peptides are still being developed. Based on our extensive experience with analyzing a wide range of SID-MRM-MS data, we set forth a methodology for analysis that encompasses significant aspects ranging from data quality assessment, assay characterization including calibration curves, limits of detection (LOD) and quantification (LOQ), and measurement of intra- and interlaboratory precision. We draw upon publicly available seminal datasets to illustrate our methods and algorithms. PMID:23176545
Mani, D R; Abbatiello, Susan E; Carr, Steven A
2012-01-01
Multiple reaction monitoring mass spectrometry (MRM-MS) with stable isotope dilution (SID) is increasingly becoming a widely accepted assay for the quantification of proteins and peptides. These assays have shown great promise in relatively high throughput verification of candidate biomarkers. While the use of MRM-MS assays is well established in the small molecule realm, their introduction and use in proteomics is relatively recent. As such, statistical and computational methods for the analysis of MRM-MS data from proteins and peptides are still being developed. Based on our extensive experience with analyzing a wide range of SID-MRM-MS data, we set forth a methodology for analysis that encompasses significant aspects ranging from data quality assessment, assay characterization including calibration curves, limits of detection (LOD) and quantification (LOQ), and measurement of intra- and interlaboratory precision. We draw upon publicly available seminal datasets to illustrate our methods and algorithms.
A Quantitative PCR-Electrochemical Genosensor Test for the Screening of Biotech Crops
Moura-Melo, Suely; Miranda-Castro, Rebeca; de-los-Santos-Álvarez, Noemí; Miranda-Ordieres, Arturo J.; dos Santos Junior, José Ribeiro; da Silva Fonseca, Rosana A.; Lobo-Castañón, María Jesús
2017-01-01
The design of screening methods for the detection of genetically modified organisms (GMOs) in food would improve the efficiency in their control. We report here a PCR amplification method combined with a sequence-specific electrochemical genosensor for the quantification of a DNA sequence characteristic of the 35S promoter derived from the cauliflower mosaic virus (CaMV). Specifically, we employ a genosensor constructed by chemisorption of a thiolated capture probe and p-aminothiophenol gold surfaces to entrap on the sensing layer the unpurified PCR amplicons, together with a signaling probe labeled with fluorescein. The proposed test allows for the determination of a transgene copy number in both hemizygous (maize MON810 trait) and homozygous (soybean GTS40-3-2) transformed plants, and exhibits a limit of quantification of at least 0.25% for both kinds of GMO lines. PMID:28420193
Casals, I; Reixach, M; Amat, J; Fuentes, M; Serra-Majem, L
1996-10-25
An HPLC isocratic method with pre-column derivatization and UV detection for the quantification of cyclamate and cyclohexylamine in urine samples is described. The method requires very little sample preparation. Free cyclohexylamine is analysed in a first run and subsequently cyclamate is analysed as cyclohexylamine, after the simple process of oxidation of the sample by means of hydrogen peroxide. Cycloheptylamine is used as internal standard. Trinitrobenzenesulfonic acid (TNBS) appears to be a good reagent for the pre-column derivatization. The time per run is 15 min; the coefficients of variation of the assays range from 1.1 to 5.5%; the limits of detection are 0.09 and 0.11 ppm for cyclohexylamine and cyclamate anion, respectively. The system described has always performed efficiently, with a high degree of stability, in daily routine work.
Shah, Umang; Patel, Shraddha; Raval, Manan
2018-01-01
High performance liquid chromatography is an integral analytical tool in assessing drug product stability. HPLC methods should be able to separate, detect, and quantify the various drug-related degradants that can form on storage or manufacturing, plus detect any drug-related impurities that may be introduced during synthesis. A simple, economic, selective, precise, and stability-indicating HPLC method has been developed and validated for analysis of Rifampicin (RIFA) and Piperine (PIPE) in bulk drug and in the formulation. Reversed-phase chromatography was performed on a C18 column with Buffer (Potassium Dihydrogen Orthophosphate) pH 6.5 and Acetonitrile, 30:70), (%, v/v), as mobile phase at a flow rate of 1 mL min-1. The detection was performed at 341 nm and sharp peaks were obtained for RIFA and PIPE at retention time of 3.3 ± 0.01 min and 5.9 ± 0.01 min, respectively. The detection limits were found to be 2.385 ng/ml and 0.107 ng/ml and quantification limits were found to be 7.228ng/ml and 0.325ng/ml for RIFA and PIPE, respectively. The method was validated for accuracy, precision, reproducibility, specificity, robustness, and detection and quantification limits, in accordance with ICH guidelines. Stress study was performed on RIFA and PIPE and it was found that these degraded sufficiently in all applied chemical and physical conditions. Thus, the developed RP-HPLC method was found to be suitable for the determination of both the drugs in bulk as well as stability samples of capsule containing various excipients. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
El-Masry, Amal A; Hammouda, Mohammed E A; El-Wasseef, Dalia R; El-Ashry, Saadia M
2018-02-15
Two simple, sensitive, rapid, validated and cost effective spectroscopic methods were established for quantification of antihistaminic drug azelastine (AZL) in bulk powder as well as in pharmaceutical dosage forms. In the first method (A) the absorbance difference between acidic and basic solutions was measured at 228nm, whereas in the second investigated method (B) the binary complex formed between AZL and Eosin Y in acetate buffer solution (pH3) was measured at 550nm. Different criteria that have critical influence on the intensity of absorption were deeply studied and optimized so as to achieve the highest absorption. The proposed methods obeyed Beer ' s low in the concentration range of (2.0-20.0μg·mL -1 ) and (0.5-15.0μg·mL -1 ) with % recovery±S.D. of (99.84±0.87), (100.02±0.78) for methods (A) and (B), respectively. Furthermore, the proposed methods were easily applied for quality control of pharmaceutical preparations without any conflict with its co-formulated additives, and the analytical results were compatible with those obtained by the comparison one with no significant difference as insured by student's t-test and the variance ratio F-test. Validation of the proposed methods was performed according the ICH guidelines in terms of linearity, limit of quantification, limit of detection, accuracy, precision and specificity, where the analytical results were persuasive. Copyright © 2017 Elsevier B.V. All rights reserved.
Al-Majed, Abdulrahman A
2009-08-15
A direct chiral high-performance liquid chromatography (HPLC) method was developed and validated for the resolution and quantification of antiepileptic drug enantiomers, R-(-)- and S-(+)-vigabatrin (gamma-vinyl-gamma-aminobutyric acid) in pharmaceutical products. The separation was optimized on a macrocyclic glycopeptide antibiotic chiral stationary phase (CSP) based on teicoplanin aglycone, chirobiotic (TAG), using a mobile phase system containing ethanol-water (80:20, v/v), at a flow rate of 0.4ml/min and UV detection set at 210nm. The stability of vigabatrin enantiomers under different degrees of temperature was also studied. The enantiomers of vigabatrin were separated from each other. The calibration curves were linear over a range of 100-1600microg/ml (r=0.999) for both enantiomers. The overall recoveries of R-(-)- and S-(+)-vigabatrin enantiomers from pharmaceutical products were in the range of 98.3-99.8% with %RSD ranged from 0.48 to 0.52%. The limit of quantification (LOQ) and limit of detection (LOD) for each enantiomer were 100 and 25microg/ml, respectively. No interferences were found from commonly co-formulated excipients.
Alam, Prawez
2013-08-01
To develop and validate a simple, accurate HPTLC method for the analysis of 8-gingerol and to determine the quantity of 8-gingerol in Zingiber officinale extract and ginger-containing dietary supplements, teas and commercial creams. The analysis was performed on 10×20 cm aluminium-backed plates coated with 0.2 mm layers of silica gel 60 F254 (E-Merck, Germany) with n-hexane: ethyl acetate 60: 40 (v/v) as mobile phase. Camag TLC Scanner III was used for the UV densitometric scanning at 569. This system was found to give a compact spot of 8-gingerol at retention factor (Rf) value of (0.39±0.04) and linearity was found in the ranges 50-500 ng/spot (r (2)=0.9987). Limit of detection (12.76 ng/spot), limit of quantification (26.32 ng/spot), accuracy (less than 2 %) and recovery (ranging from 98.22-99.20) were found satisfactory. The HPTLC method developed for quantification of 8-gingerol was found to be simple, accurate, reproducible, sensitive and is applicable to the analysis of 8-gingerol in Zingiber officinale extract and ginger-containing dietary supplements, teas and commercial creams.
Venturelli, Gustavo L; Brod, Fábio C A; Rossi, Gabriela B; Zimmermann, Naíra F; Oliveira, Jaison P; Faria, Josias C; Arisi, Ana C M
2014-11-01
The Embrapa 5.1 genetically modified (GM) common bean was approved for commercialization in Brazil. Methods for the quantification of this new genetically modified organism (GMO) are necessary. The development of a suitable endogenous reference is essential for GMO quantification by real-time PCR. Based on this, a new taxon-specific endogenous reference quantification assay was developed for Phaseolus vulgaris L. Three genes encoding common bean proteins (phaseolin, arcelin, and lectin) were selected as candidates for endogenous reference. Primers targeting these candidate genes were designed and the detection was evaluated using the SYBR Green chemistry. The assay targeting lectin gene showed higher specificity than the remaining assays, and a hydrolysis probe was then designed. This assay showed high specificity for 50 common bean samples from two gene pools, Andean and Mesoamerican. For GM common bean varieties, the results were similar to those obtained for non-GM isogenic varieties with PCR efficiency values ranging from 92 to 101 %. Moreover, this assay presented a limit of detection of ten haploid genome copies. The primers and probe developed in this work are suitable to detect and quantify either GM or non-GM common bean.
Chen, Yao; Zane, Nicole R; Thakker, Dhiren R; Wang, Michael Zhuo
2016-07-01
Flavin-containing monooxygenases (FMOs) have a significant role in the metabolism of small molecule pharmaceuticals. Among the five human FMOs, FMO1, FMO3, and FMO5 are the most relevant to hepatic drug metabolism. Although age-dependent hepatic protein expression, based on immunoquantification, has been reported previously for FMO1 and FMO3, there is very little information on hepatic FMO5 protein expression. To overcome the limitations of immunoquantification, an ultra-performance liquid chromatography (UPLC)-multiple reaction monitoring (MRM)-based targeted quantitative proteomic method was developed and optimized for the quantification of FMO1, FMO3, and FMO5 in human liver microsomes (HLM). A post-in silico product ion screening process was incorporated to verify LC-MRM detection of potential signature peptides before their synthesis. The developed method was validated by correlating marker substrate activity and protein expression in a panel of adult individual donor HLM (age 39-67 years). The mean (range) protein expression of FMO3 and FMO5 was 46 (26-65) pmol/mg HLM protein and 27 (11.5-49) pmol/mg HLM protein, respectively. To demonstrate quantification of FMO1, a panel of fetal individual donor HLM (gestational age 14-20 weeks) was analyzed. The mean (range) FMO1 protein expression was 7.0 (4.9-9.7) pmol/mg HLM protein. Furthermore, the ontogenetic protein expression of FMO5 was evaluated in fetal, pediatric, and adult HLM. The quantification of FMO proteins also was compared using two different calibration standards, recombinant proteins versus synthetic signature peptides, to assess the ratio between holoprotein versus total protein. In conclusion, a UPLC-MRM-based targeted quantitative proteomic method has been developed for the quantification of FMO enzymes in HLM. Copyright © 2016 by The American Society for Pharmacology and Experimental Therapeutics.
Chen, Yao; Zane, Nicole R.; Thakker, Dhiren R.
2016-01-01
Flavin-containing monooxygenases (FMOs) have a significant role in the metabolism of small molecule pharmaceuticals. Among the five human FMOs, FMO1, FMO3, and FMO5 are the most relevant to hepatic drug metabolism. Although age-dependent hepatic protein expression, based on immunoquantification, has been reported previously for FMO1 and FMO3, there is very little information on hepatic FMO5 protein expression. To overcome the limitations of immunoquantification, an ultra-performance liquid chromatography (UPLC)-multiple reaction monitoring (MRM)-based targeted quantitative proteomic method was developed and optimized for the quantification of FMO1, FMO3, and FMO5 in human liver microsomes (HLM). A post-in silico product ion screening process was incorporated to verify LC-MRM detection of potential signature peptides before their synthesis. The developed method was validated by correlating marker substrate activity and protein expression in a panel of adult individual donor HLM (age 39–67 years). The mean (range) protein expression of FMO3 and FMO5 was 46 (26–65) pmol/mg HLM protein and 27 (11.5–49) pmol/mg HLM protein, respectively. To demonstrate quantification of FMO1, a panel of fetal individual donor HLM (gestational age 14–20 weeks) was analyzed. The mean (range) FMO1 protein expression was 7.0 (4.9–9.7) pmol/mg HLM protein. Furthermore, the ontogenetic protein expression of FMO5 was evaluated in fetal, pediatric, and adult HLM. The quantification of FMO proteins also was compared using two different calibration standards, recombinant proteins versus synthetic signature peptides, to assess the ratio between holoprotein versus total protein. In conclusion, a UPLC-MRM-based targeted quantitative proteomic method has been developed for the quantification of FMO enzymes in HLM. PMID:26839369
Geissler, Mareen; Oellig, Claudia; Moss, Karin; Schwack, Wolfgang; Henkel, Marius; Hausmann, Rudolf
2017-02-15
A high-performance thin-layer chromatography method has been established for the identification and simultaneous quantification of the cyclic lipopeptides Surfactin, Iturin A and Fengycin in Bacillus culture samples. B. subtilis DSM 10 T , B. amyloliquefaciens DSM 7 T and B. methylotrophicus DSM 23117 were used as model strains. Culture samples indicated that a sample pretreatment is necessary in order to run HPTLC analyses. A threefold extraction of the cell-free broth with the solvent chloroform/methanol (2:1, v/v) gave best results, when all three lipopeptides were included in the analysis. For the mobile phase, a two-step development was considered most suitable. The first development is conducted with chloroform/methanol/water (65:25:4, v/v/v) over a migration distance of 60mm and the second development using butanol/ethanol/0.1% acetic acid (1:4:1, v/v/v) over a migration distance of 60mm, as well. The method was validated according to Validation of Analytical Procedures: Methodology (FDA Guidance) with respect to the parameters linearity, limit of detection (LOD), limit of quantification (LOQ), precision, accuracy and recovery rate. A linear range with R 2 >0.99 was obtained for all samples from 30ng/zone up to 600ng/zone. The results indicated that quantification of Surfactin has to be performed after the first development (hR F =44), while Fengycin is quantified after the second development (hR F =36, hR F range=20-40). For Iturin A, the results demonstrated that quantification is in favor after the first (hR F =19) development, but also possible after the second (hR F =59) development. LOD and LOQ for Surfactin and Iturin A after the first development, and Fengycin after the second development were determined to be 16ng/zone and 47ng/zone, 13ng/zone and 39ng/zone, and 27ng/zone and 82ng/zone, respectively. Results further revealed the highly accurate and precise character of the developed method with a good inter- and intraday reproducibility. For the precision and accuracy, expressed as % recovery and relative standard deviation, respectively, the determined values did not exceed ±15% as specified by the FDA Guidance. The recovery assay conducted for samples obtained from two strains with the solvent chloroform/methanol (2:1, v/v), which was determined to be most suitable if all three lipopeptides are of interest, gave recoveries of 96.5% and 99.6%, 68.6% and 71.6%, and 102.5% and 95.2% for Surfactin, Iturin A and Fengycin, respectively. Overall, a suitable and reliable method for the simultaneous quantification of the lipopeptides Surfactin, Iturin A and Fengycin in biological samples using HPTLC was successfully developed and validated. Copyright © 2016 Elsevier B.V. All rights reserved.
Migration studies of nickel and chromium from ceramic and glass tableware into food simulants.
Szynal, Tomasz; Rebeniak, Małgorzata; Mania, Monika
In addition to the release of lead and cadmium from ceramic and glass vessels, (acceptable limits being set by the EU 84/500/EC Directive), other harmful metals can migrate, such as nickel and chromium. Permissible migration limits for these latter metals however have not yet been set in the EU legislation. Both the toxic properties of nickel and chromium and the measures taken by the European Commission Working Group on Food Contact Materials for verifying permissible migration limits for lead, cadmium and other metals from ceramics have acted as drivers for studies on nickel and chromium release from ceramic and glass tableware. To investigate the migration of nickel and chromium into food simulants from ceramic and glassware, available on the Polish market, which are intended for coming into contact with food. Potential consumer exposure can thereby be estimated from the release of these elements into food. Tableware consisted of ceramics and glass vessels generally available on the domestic market, with inner surfaces being mainly coloured and with rim decorations. Migration of nickel and chromium studied from the ceramics was carried out in 4% acetic acid (24 ± 0.5 hrs at 22 ± 2°C), whilst that from glassware in 4% acetic acid (24 ± 0.5 hrs at 22 ± 2°C) and 0.5% citric acid (2 ± 0.1 hrs at 70 ± 2°C). The concentrations of metals which had migrated into the test solutions were measured by using flame atomic absorption spectrometry (FAAS). This analytical procedure had been previously validated by measuring nickel and chromium released into food simulants from ceramic and glass tableware where working ranges, detection limits, quantification limits, repeatability, accuracy, mean recovery and uncertainty were established. Migration of nickel and chromium was measured from 172 ceramic and 52 and glass vessels samples, with all results being below the limits of quantification (LOQ = 0.02 mg/L), excepting one instance where a 0.04 mg/L concentration of nickel was found. The validated methods for measuring chromium achieved the following parameters; 0.02 to 0.80 mg/L operating range, 0.01 mg/L detection limit, 0.02 mg/L limit of quantification, 6% repeatability, 2.8% accuracy, 102% average recovery and 11% uncertainty. For the nickel method the corresponding parameters were 0.02 to 0.80 mg/L work- ing range, 0.02 mg/L limit of quantification, 0.01 mg/L detection limit, 5% repeatability, 6.5% accuracy, 101% average recovery and 12% uncertainty. The tested ceramics and glassware did not pose a threat to human health regarding migration of nickel and chromium, and thus any potential exposure to these metals released from these products into food will be small. However, due to the toxicity of these metals, the migration of nickel and chromium is still required for articles coming into contact with food, which includes metalware. ceramic tableware, ceramics, glassware, food contact articles, nickel, chromium leaching, migration.
Jamwal, Rohitash; Topletz, Ariel R.; Ramratnam, Bharat; Akhlaghi, Fatemeh
2017-01-01
Cannabis is used widely in the United States, both recreationally and for medical purposes. Current methods for analysis of cannabinoids in human biological specimens rely on complex extraction process and lengthy analysis time. We established a rapid and simple assay for quantification of Δ9-tetrahydrocannabinol (THC), cannabidiol (CBD), 11-hydroxy Δ9-tetrahydrocannabinol (11-OH THC) and 11-nor-9-carboxy-Δ9-tetrahydrocannbinol (THC-COOH) in human plasma by U-HPLC-MS/MS using Δ9-tetrahydrocannabinol-D3 as the internal standard. Chromatographic separation was achieved on an Acquity BEH C18 column using a gradient comprising of water (0.1% formic acid) and methanol (0.1% formic acid) over a 6 min run-time. Analytes from 200 µL plasma were extracted using acetonitrile (containing 1% formic acid and THC-D3). Mass spectrometry was performed in positive ionization mode, and total ion chromatogram was used for quantification of analytes. The assay was validated according to guidelines set forth by Food and Drug Administration of United States. An eight-point calibration curve was fitted with quadratic regression (r2>0.99) from 1.56 to 100 ng mL−1 and a lower limit of quantification (LLOQ) of 1.56 ng mL−1 was achieved. Accuracy and precision calculated from six calibration curves was between 85 to 115% while the mean extraction recovery was >90% for all the analytes. Several plasma phospholipids eluted after the analytes thus did not interfere with the assay. Bench-top, freeze-thaw, auto-sampler and short-term stability ranged from 92.7 to 106.8% of nominal values. Application of the method was evaluated by quantification of analytes in human plasma from six subjects. PMID:28192758
Shao, Xi; Lv, Lishuang; Parks, Tiffany; Wu, Hou; Ho, Chi-Tang; Sang, Shengmin
2010-01-01
For the first time, a sensitive reversed-phase HPLC electrochemical array method has been developed for the quantitative analysis of eight major ginger components ([6]-, [8]-, and [10]-gingerol, [6]-, [8]-, and [10]-shogaol, [6]-paradol, and [1]-dehydrogingerdione) in eleven ginger-containing commercial products. This method was valid with unrivaled sensitivity as low as 7.3 – 20.2 pg of limit of detection and a range of 14.5 to 40.4 pg of limit of quantification. Using this method, we quantified the levels of eight ginger components in eleven different commercial products. Our results found that both levels and ratios among the eight compounds vary greatly in commercial products. PMID:21090746
Peters, Frank T; Schaefer, Simone; Staack, Roland F; Kraemer, Thomas; Maurer, Hans H
2003-06-01
The classical stimulants amphetamine, methamphetamine, ethylamphetamine and the amphetamine-derived designer drugs MDA, MDMA ('ecstasy'), MDEA, BDB and MBDB have been widely abused for a relatively long time. In recent years, a number of newer designer drugs have entered the illicit drug market. 4-Methylthioamphetamine (MTA), p-methoxyamphetamine (PMA) and p-methoxymethamphetamine (PMMA) are also derived from amphetamine. Other designer drugs are derived from piperazine, such as benzylpiperazine (BZP), methylenedioxybenzylpiperazine (MDBP), trifluoromethylphenylpiperazine (TFMPP), m-chlorophenylpiperazine (mCPP) and p-methoxyphenylpiperazine (MeOPP). A number of severe or even fatal intoxications involving these newer substances, especially PMA, have been reported. This paper describes a method for screening for and simultaneous quantification of the above-mentioned compounds and the metabolites p-hydroxyamphetamine and p-hydroxymethamphetamine (pholedrine) in human blood plasma. The analytes were analyzed by gas chromatography/mass spectrometry in the selected-ion monitoring mode after mixed-mode solid-phase extraction (HCX) and derivatization with heptafluorobutyric anhydride. The method was fully validated according to international guidelines. It was linear from 5 to 1000 micro g l(-1) for all analytes. Data for accuracy and precision were within required limits with the exception of those for MDBP. The limit of quantification was 5 micro g l(-1) for all analytes. The applicability of the assay was proven by analysis of authentic plasma samples and of a certified reference sample. This procedure should also be suitable for confirmation of immunoassay results positive for amphetamines and/or designer drugs of the ecstasy type. Copyright 2003 John Wiley & Sons, Ltd.
Hessling, Bernd; Büttner, Knut; Hecker, Michael; Becher, Dörte
2013-01-01
Quantitative LC-MALDI is an underrepresented method, especially in large-scale experiments. The additional fractionation step that is needed for most MALDI-TOF-TOF instruments, the comparatively long analysis time, and the very limited number of established software tools for the data analysis render LC-MALDI a niche application for large quantitative analyses beside the widespread LC–electrospray ionization workflows. Here, we used LC-MALDI in a relative quantification analysis of Staphylococcus aureus for the first time on a proteome-wide scale. Samples were analyzed in parallel with an LTQ-Orbitrap, which allowed cross-validation with a well-established workflow. With nearly 850 proteins identified in the cytosolic fraction and quantitative data for more than 550 proteins obtained with the MASCOT Distiller software, we were able to prove that LC-MALDI is able to process highly complex samples. The good correlation of quantities determined via this method and the LTQ-Orbitrap workflow confirmed the high reliability of our LC-MALDI approach for global quantification analysis. Because the existing literature reports differences for MALDI and electrospray ionization preferences and the respective experimental work was limited by technical or methodological constraints, we systematically compared biochemical attributes of peptides identified with either instrument. This genome-wide, comprehensive study revealed biases toward certain peptide properties for both MALDI-TOF-TOF- and LTQ-Orbitrap-based approaches. These biases are based on almost 13,000 peptides and result in a general complementarity of the two approaches that should be exploited in future experiments. PMID:23788530
Hessling, Bernd; Büttner, Knut; Hecker, Michael; Becher, Dörte
2013-10-01
Quantitative LC-MALDI is an underrepresented method, especially in large-scale experiments. The additional fractionation step that is needed for most MALDI-TOF-TOF instruments, the comparatively long analysis time, and the very limited number of established software tools for the data analysis render LC-MALDI a niche application for large quantitative analyses beside the widespread LC-electrospray ionization workflows. Here, we used LC-MALDI in a relative quantification analysis of Staphylococcus aureus for the first time on a proteome-wide scale. Samples were analyzed in parallel with an LTQ-Orbitrap, which allowed cross-validation with a well-established workflow. With nearly 850 proteins identified in the cytosolic fraction and quantitative data for more than 550 proteins obtained with the MASCOT Distiller software, we were able to prove that LC-MALDI is able to process highly complex samples. The good correlation of quantities determined via this method and the LTQ-Orbitrap workflow confirmed the high reliability of our LC-MALDI approach for global quantification analysis. Because the existing literature reports differences for MALDI and electrospray ionization preferences and the respective experimental work was limited by technical or methodological constraints, we systematically compared biochemical attributes of peptides identified with either instrument. This genome-wide, comprehensive study revealed biases toward certain peptide properties for both MALDI-TOF-TOF- and LTQ-Orbitrap-based approaches. These biases are based on almost 13,000 peptides and result in a general complementarity of the two approaches that should be exploited in future experiments.
Maublanc, Julie; Dulaurent, Sylvain; Morichon, Julien; Lachâtre, Gérard; Gaulier, Jean-michel
2015-03-01
Despite a non-invasive sampling, hair samples are generally collected in limited amounts for an obvious esthetic reason. In order to reduce the required quantity of samples, a multianalytes method allowing simultaneous identification and quantification of 35 psychoactive drugs was developed. After incubation of 50 mg of hair in a phosphate buffer pH 5 for one night at room temperature, the substances of interest were extracted by a simple liquid-liquid extraction step, with a dichloromethane/ether mixture (70:30, v/v). After evaporation under a gentle stream of nitrogen and reconstitution in formate buffer (2 mM, pH 3)/acetonitrile (90:10, v/v), twenty microliter were injected into the LC-MS/MS system for a chromatographic run of 29 min using an Atlantis T3 column (150 × 2.1 mm, 3 μm) (Waters Corp, Milford, USA) and a gradient mixture of 2 mM, pH 3.0 ammonium formate, and 2 mM, pH 3.0 ammonium formate/acetonitrile. The data acquisition was performed in scheduled MRM mode. Intra- and inter-day precisions, estimated using the coefficient of variation and relative bias, were lower than 20 % for all concentration levels, except for two compounds. The limits of detection and quantification ranged from 0.5 to 10 pg/mg. After complete validation, this method has been successfully used in several forensic cases, three of which are reported.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Zhou; Adams, Rachel M; Chourey, Karuna
2012-01-01
A variety of quantitative proteomics methods have been developed, including label-free, metabolic labeling, and isobaric chemical labeling using iTRAQ or TMT. Here, these methods were compared in terms of the depth of proteome coverage, quantification accuracy, precision, and reproducibility using a high-performance hybrid mass spectrometer, LTQ Orbitrap Velos. Our results show that (1) the spectral counting method provides the deepest proteome coverage for identification, but its quantification performance is worse than labeling-based approaches, especially the quantification reproducibility; (2) metabolic labeling and isobaric chemical labeling are capable of accurate, precise, and reproducible quantification and provide deep proteome coverage for quantification. Isobaricmore » chemical labeling surpasses metabolic labeling in terms of quantification precision and reproducibility; (3) iTRAQ and TMT perform similarly in all aspects compared in the current study using a CID-HCD dual scan configuration. Based on the unique advantages of each method, we provide guidance for selection of the appropriate method for a quantitative proteomics study.« less
Electrochemical Quantification of the Antioxidant Capacity of Medicinal Plants Using Biosensors
Rodríguez-Sevilla, Erika; Ramírez-Silva, María-Teresa; Romero-Romo, Mario; Ibarra-Escutia, Pedro; Palomar-Pardavé, Manuel
2014-01-01
The working area of a screen-printed electrode, SPE, was modified with the enzyme tyrosinase (Tyr) using different immobilization methods, namely entrapment with water-soluble polyvinyl alcohol (PVA), cross-linking using glutaraldehyde (GA), and cross-linking using GA and human serum albumin (HSA); the resulting electrodes were termed SPE/Tyr/PVA, SPE/Tyr/GA and SPE/Tyr/HSA/GA, respectively. These biosensors were characterized by means of amperometry and EIS techniques. From amperometric evaluations, the apparent Michaelis-Menten constant, Km′, of each biosensor was evaluated while the respective charge transfer resistance, Rct, was assessed from impedance measurements. It was found that the SPE/Tyr/GA had the smallest Km′ (57 ± 7) μM and Rct values. This electrode also displayed both the lowest detection and quantification limits for catechol quantification. Using the SPE/Tyr/GA, the Trolox Equivalent Antioxidant Capacity (TEAC) was determined from infusions prepared with “mirto” (Salvia microphylla), “hHierba dulce” (Lippia dulcis) and “salve real” (Lippia alba), medicinal plants commonly used in Mexico. PMID:25111237
Electrochemical quantification of the antioxidant capacity of medicinal plants using biosensors.
Rodríguez-Sevilla, Erika; Ramírez-Silva, María-Teresa; Romero-Romo, Mario; Ibarra-Escutia, Pedro; Palomar-Pardavé, Manuel
2014-08-08
The working area of a screen-printed electrode, SPE, was modified with the enzyme tyrosinase (Tyr) using different immobilization methods, namely entrapment with water-soluble polyvinyl alcohol (PVA), cross-linking using glutaraldehyde (GA), and cross-linking using GA and human serum albumin (HSA); the resulting electrodes were termed SPE/Tyr/PVA, SPE/Tyr/GA and SPE/Tyr/HSA/GA, respectively. These biosensors were characterized by means of amperometry and EIS techniques. From amperometric evaluations, the apparent Michaelis-Menten constant, Km', of each biosensor was evaluated while the respective charge transfer resistance, Rct, was assessed from impedance measurements. It was found that the SPE/Tyr/GA had the smallest Km' (57 ± 7) µM and Rct values. This electrode also displayed both the lowest detection and quantification limits for catechol quantification. Using the SPE/Tyr/GA, the Trolox Equivalent Antioxidant Capacity (TEAC) was determined from infusions prepared with "mirto" (Salvia microphylla), "hHierba dulce" (Lippia dulcis) and "salve real" (Lippia alba), medicinal plants commonly used in Mexico.
Microvolume Protein Concentration Determination using the NanoDrop 2000c Spectrophotometer
Desjardins, Philippe; Hansen, Joel B.; Allen, Michael
2009-01-01
Traditional spectrophotometry requires placing samples into cuvettes or capillaries. This is often impractical due to the limited sample volumes often used for protein analysis. The Thermo Scientific NanoDrop 2000c Spectrophotometer solves this issue with an innovative sample retention system that holds microvolume samples between two measurement surfaces using the surface tension properties of liquids, enabling the quantification of samples in volumes as low as 0.5-2 μL. The elimination of cuvettes or capillaries allows real time changes in path length, which reduces the measurement time while greatly increasing the dynamic range of protein concentrations that can be measured. The need for dilutions is also eliminated, and preparations for sample quantification are relatively easy as the measurement surfaces can be simply wiped with laboratory wipe. This video article presents modifications to traditional protein concentration determination methods for quantification of microvolume amounts of protein using A280 absorbance readings or the BCA colorimetric assay. PMID:19890248
Takabatake, Reona; Akiyama, Hiroshi; Sakata, Kozue; Onishi, Mari; Koiwa, Tomohiro; Futo, Satoshi; Minegishi, Yasutaka; Teshima, Reiko; Mano, Junichi; Furui, Satoshi; Kitta, Kazumi
2011-01-01
A novel real-time PCR-based analytical method was developed for the event-specific quantification of a genetically modified (GM) soybean event; A2704-12. During the plant transformation, DNA fragments derived from pUC19 plasmid were integrated in A2704-12, and the region was found to be A2704-12 specific. The pUC19-derived DNA sequences were used as primers for the specific detection of A2704-12. We first tried to construct a standard plasmid for A2704-12 quantification using pUC19. However, non-specific signals appeared with both qualitative and quantitative PCR analyses using the specific primers with pUC19 as a template, and we then constructed a plasmid using pBR322. The conversion factor (C(f)), which is required to calculate the amount of the genetically modified organism (GMO), was experimentally determined with two real-time PCR instruments, the Applied Biosystems 7900HT and the Applied Biosystems 7500. The determined C(f) values were both 0.98. The quantitative method was evaluated by means of blind tests in multi-laboratory trials using the two real-time PCR instruments. The limit of quantitation for the method was estimated to be 0.1%. The trueness and precision were evaluated as the bias and reproducibility of relative standard deviation (RSD(R)), and the determined bias and RSD(R) values for the method were each less than 20%. These results suggest that the developed method would be suitable for practical analyses for the detection and quantification of A2704-12.
Li, Ke; Buchinger, Tyler J.; Bussy, Ugo; Fissette, Skye D.; Johnson, Nicholas; Li, Weiming
2015-01-01
Many fishes are hypothesized to use bile acids (BAs) as chemical cues, yet quantification of BAs in biological samples and the required methods remain limited. Here, we present an UHPLC–MS/MS method for simultaneous, sensitive, and rapid quantification of 15 BAs, including free, taurine, and glycine conjugated BAs, and application of the method to fecal samples from lake charr (Salvelinus namaycush). The analytes were separated on a C18 column with acetonitrile–water (containing 7.5 mM ammonium acetate and 0.1% formic acid) as mobile phase at a flow rate of 0.25 mL/min for 12 min. BAs were monitored with a negative electrospray triple quadrupole mass spectrometer (Xevo TQ-S™). Calibration curves of 15 BAs were linear over the concentration range of 1.00–5,000 ng/mL. Validation revealed that the method was specific, accurate, and precise. The method was applied to quantitative analysis of feces extract of fry lake charr and the food they were eating. The concentrations of analytes CA, TCDCA, TCA, and CDCA were 242.3, 81.2, 60.7, and 36.2 ng/mg, respectively. However, other taurine conjugated BAs, TUDCA, TDCA, and THDCA, were not detected in feces of lake charr. Interestingly, TCA and TCDCA were detected at high concentrations in food pellets, at 71.9 and 38.2 ng/mg, respectively. Application of the method to feces samples from lake charr supported a role of BAs as chemical cues, and will enhance further investigation of BAs as chemical cues in other fish species.
Irie, Kei; Shobu, Saori; Hiratsuji, Seika; Yamasaki, Yuta; Nanjo, Shigeki; Kokan, Chiyuki; Hata, Akito; Kaji, Reiko; Masago, Katsuhiro; Fujita, Shiro; Okada, Yutaka; Katakami, Nobuyuki; Fukushima, Shoji
2018-06-15
A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the quantification of gefitinib in dried blood spots (DBSs). Gefitinib was extracted with methanol from DBS of 3 mm in diameter and detected using a triple quadrupole mass spectrometer. The method was validated by evaluating its precision, accuracy, selectivity, carryover, matrix effect, recovery, and stability. For clinical validation, paired finger-prick DBS and plasma concentrations were compared for 10 patients with non-small cell lung cancer (NSCLC) taking gefitinib. The calibration linear range was 37.5-2400 ng/mL (coefficient of determination [R 2 ] = 0.99), encompassing the therapeutic concentrations of gefitinib. The accuracy and precision were within 15% of the quality control (QC) concentrations of 80, 200, and 2000 ng/mL. The lower limit of quantification was determined to be 40 ng/mL. Gefitinib was stable in DBSs for up to 5 months at room temperature and -20 °C, and at 40 °C for 24 h. A good correlation was observed between the gefitinib levels measured by the DBS method and plasma concentrations (R 2 = 0.99). This method provides a simple, fast, and accurate approach to the quantitative analysis of gefitinib in finger-prick DBSs. The method would be useful for minimally invasive evaluation of the clinical gefitinib blood concentration. Copyright © 2018 Elsevier B.V. All rights reserved.
Valente, Maria João; Carvalho, Félix; Bastos, M Lourdes; Carvalho, Márcia; de Pinho, Paula Guedes
2010-11-15
Acute renal failure is a common finding in cocaine abusers. While cocaine metabolism may contribute to its nephrotoxic mechanisms, its pharmacokinetics in kidney cells is hitherto to be clarified. Primary cultures of human proximal tubular cells (HPTCs) provide a well-characterized in vitro model, phenotypically representative of HPTCs in vivo. Thus, the present work describes the first sensitive gas chromatography/ion trap-mass spectrometry (GC/IT-MS) method for measurement of cocaine and its metabolites benzoylecgonine (BE) and norcocaine (NCOC) using a primary culture of HPTCs as cellular matrix, following solid phase extraction (SPE) and derivatization with N-methyl-N-(trimethylsilyl)trifluoroacetamide (MSTFA). The application of this methodology also enables the identification of two other cocaine metabolites: ecgonine methyl ester (EME) and anhydroecgonine methyl ester (AEME). The validation of the method was performed through the evaluation of selectivity, linearity, precision and accuracy, limit of detection (LOD), and limit of quantification (LOQ). Its applicability was demonstrated through the quantification of cocaine, BE and NCOC in primary cultured HPTCs after incubation, at physiological conditions, with 1 mM cocaine for 72 h. The developed GC/IT-MS method was found to be linear (r² > 0.99). The intra-day precision varied between 3.6% and 13.5% and the values of accuracy between 92.7% and 111.9%. The LOD values for cocaine, BE and NCOC were 0.97±0.09, 0.40±0.04 and 20.89±1.81 ng/mL, respectively, and 3.24±0.30, 1.34±0.14 and 69.62±6.05 ng/mL as LOQ values. Copyright © 2010 Elsevier B.V. All rights reserved.
Pereira, Lara; Pujol, Marta; Garcia-Mas, Jordi; Phillips, Michael A
2017-07-01
Ethylene is a gaseous plant hormone involved in defense, adaptations to environmental stress and fruit ripening. Its relevance to the latter makes its detection highly useful for physiologists interested in the onset of ripening. Produced as a sharp peak during the respiratory burst, ethylene is biologically active at tens of nl L -1 . Reliable quantification at such concentrations generally requires specialized instrumentation. Here we present a rapid, high-sensitivity method for detecting ethylene in attached fruit using a conventional gas chromatography-mass spectrometry (GC-MS) system and in situ headspace collection chambers. We apply this method to melon (Cucumis melo L.), a unique species consisting of climacteric and non-climacteric varieties, with a high variation in the climacteric phenotype among climacteric types. Using a population of recombinant inbred lines (RILs) derived from highly climacteric ('Védrantais', cantalupensis type) and non-climacteric ('Piel de Sapo', inodorus type) parental lines, we observed a significant variation for the intensity, onset and duration of the ethylene burst during fruit ripening. Our method does not require concentration, sampling times over 1 h or fruit harvest. We achieved a limit of detection of 0.41 ± 0.04 nl L -1 and a limit of quantification of 1.37 ± 0.13 nl L -1 with an analysis time per sample of 2.6 min. Validation of the analytical method indicated that linearity (>98%), precision (coefficient of variation ≤2%) and sensitivity compared favorably with dedicated optical sensors. This study adds to evidence of the characteristic climacteric ethylene burst as a complex trait whose intensity in our RIL population lies along a continuum in addition to two extremes. © 2017 The Authors The Plant Journal © 2017 John Wiley & Sons Ltd.
Gallic Acid: Review of the Methods of Determination and Quantification.
Fernandes, Felipe Hugo Alencar; Salgado, Hérida Regina Nunes
2016-05-03
Gallic acid (3,4,5 trihydroxybenzoic acid) is a secondary metabolite present in most plants. This metabolite is known to exhibit a range of bioactivities including antioxidant, antimicrobial, anti-inflammatory, and anticancer. There are various methods to analyze gallic acid including spectrometry, chromatography, and capillary electrophoresis, among others. They have been developed to identify and quantify this active ingredient in most biological matrices. The aim of this article is to review the available information on analytical methods for gallic acid, as well as presenting the advantages and limitations of each technique.
Rapid quantification of plant-powdery mildew interactions by qPCR and conidiospore counts.
Weßling, Ralf; Panstruga, Ralph
2012-08-31
The powdery mildew disease represents a valuable patho-system to study the interaction between plant hosts and obligate biotrophic fungal pathogens. Numerous discoveries have been made on the basis of the quantitative evaluation of plant-powdery mildew interactions, especially in the context of hyper-susceptible and/or resistant plant mutants. However, the presently available methods to score the pathogenic success of powdery mildew fungi are laborious and thus not well suited for medium- to high-throughput analysis. Here we present two new protocols that allow the rapid quantitative assessment of powdery mildew disease development. One procedure depends on quantitative polymerase chain reaction (qPCR)-based evaluation of fungal biomass, while the other relies on the quantification of fungal conidiospores. We validated both techniques using the powdery mildew pathogen Golovinomyces orontii on a set of hyper-susceptible and resistant Arabidopsis thaliana mutants and found that both cover a wide dynamic range of one to two (qPCR) and four to five (quantification of conidia) orders of magnitude, respectively. The two approaches yield reproducible results and are easy to perform without specialized equipment. The qPCR and spore count assays rapidly and reproducibly quantify powdery mildew pathogenesis. Our methods are performed at later stages of infection and discern mutant phenotypes accurately. The assays therefore complement currently used procedures of powdery mildew quantification and can overcome some of their limitations. In addition, they can easily be adapted to other plant-powdery mildew patho-systems.
Kretschmer, Philip M; Bannister, Austin M; O Brien, Molly K; MacManus-Spencer, Laura A; Paulick, Margot G
2016-10-15
Trehalose is an important disaccharide that is used as a cellular protectant by many different organisms, helping these organisms better survive extreme conditions, such as dehydration, oxidative stress, and freezing temperatures. Methods to detect and accurately measure trehalose from different organisms will help us gain a better understanding of the mechanisms behind trehalose's ability to act as a cellular protectant. A liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay using selected reaction monitoring mode for the detection and quantification of trehalose using maltose as an internal standard has been developed. This assay uses a commercially available LC column for trehalose separation and a standard triple quadrupole mass spectrometer, thus allowing many scientists to take advantage of this simple assay. The calibration curve from 3 to 100μM trehalose was fit best by a single polynomial. This LC-MS/MS assay directly detects and accurately quantifies trehalose, with an instrument limit of detection (LOD) that is 2-1000 times more sensitive than the most commonly-used assays for trehalose detection and quantification. Furthermore, this assay was used to detect and quantify endogenous trehalose produced by Escherichia coli (E. coli) cells, which were found to have an intracellular concentration of 8.5±0.9mM trehalose. This method thus shows promise for the reliable detection and quantification of trehalose from different biological sources. Copyright © 2016 Elsevier B.V. All rights reserved.
Kennedy, Jacob J.; Yan, Ping; Zhao, Lei; Ivey, Richard G.; Voytovich, Uliana J.; Moore, Heather D.; Lin, Chenwei; Pogosova-Agadjanyan, Era L.; Stirewalt, Derek L.; Reding, Kerryn W.; Whiteaker, Jeffrey R.; Paulovich, Amanda G.
2016-01-01
A major goal in cell signaling research is the quantification of phosphorylation pharmacodynamics following perturbations. Traditional methods of studying cellular phospho-signaling measure one analyte at a time with poor standardization, rendering them inadequate for interrogating network biology and contributing to the irreproducibility of preclinical research. In this study, we test the feasibility of circumventing these issues by coupling immobilized metal affinity chromatography (IMAC)-based enrichment of phosphopeptides with targeted, multiple reaction monitoring (MRM) mass spectrometry to achieve precise, specific, standardized, multiplex quantification of phospho-signaling responses. A multiplex immobilized metal affinity chromatography- multiple reaction monitoring assay targeting phospho-analytes responsive to DNA damage was configured, analytically characterized, and deployed to generate phospho-pharmacodynamic curves from primary and immortalized human cells experiencing genotoxic stress. The multiplexed assays demonstrated linear ranges of ≥3 orders of magnitude, median lower limit of quantification of 0.64 fmol on column, median intra-assay variability of 9.3%, median inter-assay variability of 12.7%, and median total CV of 16.0%. The multiplex immobilized metal affinity chromatography- multiple reaction monitoring assay enabled robust quantification of 107 DNA damage-responsive phosphosites from human cells following DNA damage. The assays have been made publicly available as a resource to the community. The approach is generally applicable, enabling wide interrogation of signaling networks. PMID:26621847
Chan, Tao
2012-01-01
CT has become an established method for calculating body composition, but it requires data from the whole body, which are not typically obtained in routine PET/CT examinations. A computerized scheme that evaluates whole-body lean body mass (LBM) based on CT data from limited-whole-body coverage was developed. The LBM so obtained was compared with results from conventional predictive equations. LBM can be obtained automatically from limited-whole-body CT data by 3 means: quantification of body composition from CT images in the limited-whole-body scan, based on thresholding of CT attenuation; determination of the range of coverage based on a characteristic trend of changing composition across different levels and pattern recognition of specific features at strategic positions; and estimation of the LBM of the whole body on the basis of a predetermined relationship between proportion of fat mass and extent of coverage. This scheme was validated using 18 whole-body PET/CT examinations truncated at different lengths to emulate limited-whole-body data. LBM was also calculated using predictive equations that had been reported for use in SUV normalization. LBM derived from limited-whole-body data using the proposed method correlated strongly with LBM derived from whole-body CT data, with correlation coefficients ranging from 0.991 (shorter coverage) to 0.998 (longer coverage) and SEMs of LBM ranging from 0.14 to 0.33 kg. These were more accurate than results from different predictive equations, which ranged in correlation coefficient from 0.635 to 0.970 and in SEM from 0.64 to 2.40 kg. LBM of the whole body could be automatically estimated from CT data of limited-whole-body coverage typically acquired in PET/CT examinations. This estimation allows more accurate and consistent quantification of metabolic activity of tumors based on LBM-normalized standardized uptake value.
Chericoni, Silvio; Stefanelli, Fabio; Da Valle, Ylenia; Giusiani, Mario
2015-09-01
A sensitive and reliable method for extraction and quantification of benzoylecgonine (BZE) and cocaine (COC) in urine is presented. Propyl-chloroformate was used as derivatizing agent, and it was directly added to the urine sample: the propyl derivative and COC were then recovered by liquid-liquid extraction procedure. Gas chromatography-mass spectrometry was used to detect the analytes in selected ion monitoring mode. The method proved to be precise for BZE and COC both in term of intraday and interday analysis, with a coefficient of variation (CV)<6%. Limits of detection (LOD) were 2.7 ng/mL for BZE and 1.4 ng/mL for COC. The calibration curve showed a linear relationship for BZE and COC (r2>0.999 and >0.997, respectively) within the range investigated. The method, applied to thirty authentic samples, showed to be very simple, fast, and reliable, so it can be easily applied in routine analysis for the quantification of BZE and COC in urine samples. © 2015 American Academy of Forensic Sciences.
Tessonnière, H; Vidal, S; Barnavon, L; Alexandre, H; Remize, F
2009-02-28
Because the yeast Brettanomyces produces volatile phenols and acetic acid, it is responsible for wine spoilage. The uncontrolled accumulation of these molecules in wine leads to sensorial defects that compromise wine quality. The need for a rapid, specific, sensitive and reliable method to detect this spoilage yeast has increased over the last decade. All these requirements are met by real-time PCR. We here propose improvements of existing methods to enhance the robustness of the assay. Six different protocols to isolate DNA from a wine and three PCR mix compositions were tested, and the best method was selected. Insoluble PVPP addition during DNA extraction by a classical phenol:chloroform protocol succeeded in the relief of PCR inhibitors from wine. We developed an internal control which was efficient to avoid false negative results due to decreases in the efficiency of DNA isolation and/or amplification. The method was evaluated by an intra-laboratory study for its specificity, linearity, repeatability and reproducibility. A standard curve was established from 14 different wines artificially inoculated. The quantification limit was 31 cfu/mL.
Bekiroglu, Somer; Myrberg, Olle; Ostman, Kristina; Ek, Marianne; Arvidsson, Torbjörn; Rundlöf, Torgny; Hakkarainen, Birgit
2008-08-05
A 1H-nuclear magnetic resonance (NMR) spectroscopy method for quantitative determination of benzethonium chloride (BTC) as a constituent of grapefruit seed extract was developed. The method was validated, assessing its specificity, linearity, range, and precision, as well as accuracy, limit of quantification and robustness. The method includes quantification using an internal reference standard, 1,3,5-trimethoxybenzene, and regarded as simple, rapid, and easy to implement. A commercial grapefruit seed extract was studied and the experiments were performed on spectrometers operating at two different fields, 300 and 600 MHz for proton frequencies, the former with a broad band (BB) probe and the latter equipped with both a BB probe and a CryoProbe. The concentration average for the product sample was 78.0, 77.8 and 78.4 mg/ml using the 300 BB probe, the 600MHz BB probe and CryoProbe, respectively. The standard deviation and relative standard deviation (R.S.D., in parenthesis) for the average concentrations was 0.2 (0.3%), 0.3 (0.4%) and 0.3mg/ml (0.4%), respectively.
Richardson, Stacie L.; Hanjra, Pahul; Zhang, Gang; Mackie, Brianna D.; Peterson, Darrell L.; Huang, Rong
2016-01-01
Protein methylation and acetylation play important roles in biological processes, and misregulation of these modifications is involved in various diseases. Therefore, it is critical to understand the activities of the enzymes responsible for these modifications. Herein we describe a sensitive method for ratiometric quantification of methylated and acetylated peptides via MALDI-MS by direct spotting of enzymatic methylation and acetylation reaction mixtures without tedious purification procedures. The quantifiable detection limit for peptides with our method is approximately 10 fmol. This is achieved by increasing the signal-to-noise ratio through the addition of NH4H2PO4 to the matrix solution and reduction of the matrix α-cyanohydroxycinnamic acid concentration to 2 mg/ml. We have demonstrated the application of this method in enzyme kinetic analysis and inhibition studies. The unique feature of this method is the simultaneous quantification of multiple peptide species for investigation of processivity mechanisms. Its wide buffer compatibility makes it possible to be adapted to investigate the activity of any protein methyltransferase or acetyltransferase. PMID:25778392
Ultra-Performance Liquid Chromatographic Determination of Tocopherols and Retinol in Human Plasma
Bell, Edward C.; John, Mathew; Hughes, Rodney J.; Pham, Thu
2014-01-01
A rapid, selective and sensitive ultra-performance liquid chromatography method has been developed for the detection and quantification of tocopherols and retinol in human plasma. Alpha-tocopherol, gamma-tocopherol and retinol are assayed using fluorescence detection. Excitation/emission wavelengths are 295/330 nm and 325/470 nm for the analysis of both tocopherols and retinol, respectively. Retinol acetate is employed as the internal standard. The reversed-phase method incorporates gradient elution with a mobile phase consisting of methanol and acetonitrile. Separation of vitamin compounds is achieved using a bridged ethyl hybrid C18 column. The retention times for retinol, retinol acetate, gamma-tocopherol and alpha-tocopherol are 1.6, 1.8, 3.9 and 4.3 min, respectively. The limits of quantification for retinol, gamma-tocopherol and alpha-tocopherol were 0.02, 0.02 and 0.1 µg/mL, respectively. The assay method is suitable for the analysis of tocopherols and retinol in human plasma. The method may be applied following the ingestion of foods fortified with these fat-soluble vitamins. PMID:24170122
Sun, Juan; Li, Weixi; Zhang, Yan; Hu, Xuexu; Wu, Li; Wang, Bujun
2016-01-01
A method based on the QuEChERS (quick, easy, cheap, effective, rugged, and safe) purification combined with ultrahigh performance liquid chromatography tandem mass spectrometry (UPLC–MS/MS), was optimized for the simultaneous quantification of 25 mycotoxins in cereals. Samples were extracted with a solution containing 80% acetonitrile and 0.1% formic acid, and purified with QuEChERS before being separated by a C18 column. The mass spectrometry was conducted by using positive electrospray ionization (ESI+) and multiple reaction monitoring (MRM) models. The method gave good linear relations with regression coefficients ranging from 0.9950 to 0.9999. The detection limits ranged from 0.03 to 15.0 µg·kg−1, and the average recovery at three different concentrations ranged from 60.2% to 115.8%, with relative standard deviations (RSD%) varying from 0.7% to 19.6% for the 25 mycotoxins. The method is simple, rapid, accurate, and an improvement compared with the existing methods published so far. PMID:27983693
Herodes, K.
2017-01-01
A simultaneous method for quantitative determination of traces of fluoroquinolones (FQs) and sulfonamides (SAs) in edible plants fertilized with sewage sludge was developed. The compounds were extracted from the plants by rapid and simple liquid extraction followed by extracts clean-up using solid phase extraction. The eluent additive 1,1,1,3,3,3-hexafluoro-2-propanol was used for liquid chromatographic detection to achieve separation of structurally similar antimicrobials like ciprofloxacin and norfloxacin. Identification and quantification of the compounds were performed using high-performance liquid chromatography with electrospray ionization mass spectrometry in selected reaction monitoring mode. Method was validated and extraction recoveries of FQs and SAs ranged from 66% to 93%. The limit of quantifications was from 5 ng/g in the case of ofloxacin to 40 ng/g for norfloxacin. The method precision ranged from 1.43% to 2.61%. The developed novel method was used to evaluate the plats antimicrobial uptake (potato (Solanum tuberosum L.), carrot (Daucus carota L.), lettuce (Lactuca sativa L.), and wheat (Triticum vulgare L.)) from soil and migration of the analytes inside the plants. PMID:28695191
Pierini, Gastón Darío; Pinto, Victor Hugo A; Maia, Clarissa G C; Fragoso, Wallace D; Reboucas, Julio S; Centurión, María Eugenia; Pistonesi, Marcelo Fabián; Di Nezio, María Susana
2017-11-01
The quantification of zinc in over-the-counter drugs as commercial propolis extracts by molecular fluorescence technique using meso-tetrakis(4-carboxyphenyl)porphyrin (H 2 TCPP 4 ) was developed for the first time. The calibration curve is linear from 6.60 to 100 nmol L -1 of Zn 2+ . The detection and quantification limits were 6.22 nmol L -1 and 19.0 nmol L -1 , respectively. The reproducibility and repeatability calculated as the percentage variation of slopes of seven calibration curves were 6.75% and 4.61%, respectively. Commercial propolis extract samples from four Brazilian states were analyzed and the results (0.329-0.797 mg/100 mL) obtained with this method are in good agreement with that obtained with the Atomic Absorption Spectroscopy (AAS) technique. The method is simple, fast, of low cost and allows the analysis of the samples without pretreatment. Moreover the major advantage is that Zn-porphyrin complex presents fluorescent characteristic promoting the selectivity and sensitivity of the method. Copyright © 2017 John Wiley & Sons, Ltd.
Salvatierra Virgen, Sara; Ceballos-Magaña, Silvia Guillermina; Salvatierra-Stamp, Vilma Del Carmen; Sumaya-Martínez, Maria Teresa; Martínez-Martínez, Francisco Javier; Muñiz-Valencia, Roberto
2017-12-01
In recent years, there has been an increased concern about the presence of toxic compounds derived from the Maillard reaction produced during food cooking at high temperatures. The main toxic compounds derived from this reaction are acrylamide and hydroxymethylfurfural (HMF). The majority of analytical methods require sample treatments using solvents which are highly polluting for the environment. The difficulty of quantifying HMF in complex fried food matrices encourages the development of new analytical methods. This paper provides a rapid, sensitive and environmentally-friendly analytical method for the quantification of HMF in corn chips using HPLC-DAD. Chromatographic separation resulted in a baseline separation for HMF in 3.7 min. Sample treatment for corn chip samples first involved a leaching process using water and afterwards a solid-phase extraction (SPE) using HLB-Oasis polymeric cartridges. Sample treatment optimisation was carried out by means of Box-Behnken fractional factorial design and Response Surface Methodolog y to examine the effects of four variables (sample weight, pH, sonication time and elution volume) on HMF extraction from corn chips. The SPE-HPLC-DAD method was validated. The limits of detection and quantification were 0.82 and 2.20 mg kg -1 , respectively. Method precision was evaluated in terms of repeatability and reproducibility as relative standard deviations (RSDs) using three concentration levels. For repeatability, RSD values were 6.9, 3.6 and 2.0%; and for reproducibility 18.8, 7.9 and 2.9%. For a ruggedness study the Yuden test was applied and the result demonstrated the method as robust. The method was successfully applied to different corn chip samples.
van der Ham, M; Albersen, M; de Koning, T J; Visser, G; Middendorp, A; Bosma, M; Verhoeven-Duif, N M; de Sain-van der Velden, M G M
2012-01-27
Since vitamin B6 is essential for normal functioning of the central nervous system, there is growing need for sensitive analysis of B6 vitamers in cerebrospinal fluid (CSF). This manuscript describes the development and validation of a rapid, sensitive and accurate method for quantification of the vitamin B6 vitamers pyridoxal (PL), pyridoxamine (PM), pyridoxine (PN), pyridoxic acid (PA), pyridoxal 5'-phosphate (PLP), pyridoxamine 5'-phosphate (PMP) and pyridoxine 5'-phosphate (PNP) in human CSF. The method is based on ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) with a simple sample preparation procedure of protein precipitation using 50 g L(-1) trichloroacetic acid containing stable isotope labeled internal standards: PL-D(3) for PL and PM, PN-(13)C(4) for PN, PA-D(2) for PA and PLP-D(3) for the phosphorylated vitamers. B6 vitamers were separated (Acquity HSS-T3 UPLC column) with a buffer containing acetic acid, heptafluorobutyric acid and acetonitrile. Positive electrospray ionization was used to monitor transitions m/z 168.1→150.1 (PL), 169.1→134.1 (PM), 170.1→134.1 (PN), 184.1→148.1 (PA), 248.1→150.1 (PLP), 249.1→232.1 (PMP) and 250.1→134.1 (PNP). The method was validated at three concentration levels for each B6 vitamer in CSF. Recoveries of the internal standards were between 93% and 96%. Intra- and inter-assay variations were below 20%. Accuracy tests showed deviations from 3% (PN) to 39% (PMP). Limits of quantification were in the range of 0.03-5.37 nM. Poor results were obtained for quantification of PNP. The method was applied to CSF samples of 20 subjects and two patients on pyridoxine supplementation. Using minimal CSF volumes this method is suitable for implementation in a routine diagnostic setting. Copyright © 2011 Elsevier B.V. All rights reserved.
Ahamad, Javed; Amin, Saima; Mir, Showkat R
2015-08-01
Gymnemic acid and charantin are well-established antidiabetic phytosterols found in Gymnema sylvestre and Momordica charantia, respectively. The fact that these plants are often used together in antidiabetic poly-herbal formulations lured us to develop an HPTLC densitometric method for the simultaneous quantification of their bioactive compounds. Indirect estimation of gymnemic acid as gymnemagenin and charantin as β-sitosterol after hydrolysis has been proposed. Aluminum-backed silica gel 60 F254 plates (20 × 10 cm) were used as stationary phase and toluene-ethyl acetate-methanol-formic acid (60 : 20 : 15 : 5, v/v) as mobile phase. Developed chromatogram was scanned at 550 nm after derivatization with modified vanillin-sulfuric acid reagent. Regression analysis of the calibration data showed an excellent linear relationship between peak area versus concentration of the analytes. Linearity was found to be in the range of 500-2,500 and 100-500 ng/band for gymnemagenin and β-sitosterol, respectively. The suitability of the developed HPTLC method for simultaneous estimation of analytes was established by validating it as per the ICH guidelines. The limits of detection and quantification for gymnemagenin were found to be ≈60 and ≈190 ng/band, and those for β-sitosterol ≈30 and ≈90 ng/band, respectively. The developed method was found to be linear (r(2) = 0.9987 and 0.9943), precise (relative standard deviation <1.5 and <2% for intra- and interday precision) and accurate (mean recovery ranged between 98.43-101.44 and 98.68-100.20%) for gymnemagenin and β-sitosterol, respectively. The proposed method was also found specific and robust for quantification of both the analytes and was successfully applied to herbal drugs and in-house herbal formulation without any interference. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Microplastics in the environment: Challenges in analytical chemistry - A review.
Silva, Ana B; Bastos, Ana S; Justino, Celine I L; da Costa, João P; Duarte, Armando C; Rocha-Santos, Teresa A P
2018-08-09
Microplastics can be present in the environment as manufactured microplastics (known as primary microplastics) or resulting from the continuous weathering of plastic litter, which yields progressively smaller plastic fragments (known as secondary microplastics). Herein, we discuss the numerous issues associated with the analysis of microplastics, and to a less extent of nanoplastics, in environmental samples (water, sediments, and biological tissues), from their sampling and sample handling to their identification and quantification. The analytical quality control and quality assurance associated with the validation of analytical methods and use of reference materials for the quantification of microplastics are also discussed, as well as the current challenges within this field of research and possible routes to overcome such limitations. Copyright © 2018 Elsevier B.V. All rights reserved.
Fast BIA-amperometric determination of isoniazid in tablets.
Quintino, Maria S M; Angnes, Lúcio
2006-09-26
This paper proposes a new, fast and precise method to analyze isoniazid based on the electrochemical oxidation of the analyte at a glassy carbon electrode in 0.1M NaOH. The quantification was performed utilizing amperometry associated with batch injection analysis (BIA) technique. Fast sequential analysis (60 determinations h(-1)) in an unusually wide linear dynamic range (from 2.5 x 10(-8) to 1.0 x 10(-3)M), with high sensitivity and low limits of detection (4.1 x 10(-9)M) and quantification (1.4 x 10(-8)M), was achieved. Such characteristics allied to a good repeatability of the current responses (relative standard deviation of 0.79% for 30 measurements), were explored for the specific determination of isoniazid in isoniazid-rifampin tablet.
A Novel Weighted Kernel PCA-Based Method for Optimization and Uncertainty Quantification
NASA Astrophysics Data System (ADS)
Thimmisetty, C.; Talbot, C.; Chen, X.; Tong, C. H.
2016-12-01
It has been demonstrated that machine learning methods can be successfully applied to uncertainty quantification for geophysical systems through the use of the adjoint method coupled with kernel PCA-based optimization. In addition, it has been shown through weighted linear PCA how optimization with respect to both observation weights and feature space control variables can accelerate convergence of such methods. Linear machine learning methods, however, are inherently limited in their ability to represent features of non-Gaussian stochastic random fields, as they are based on only the first two statistical moments of the original data. Nonlinear spatial relationships and multipoint statistics leading to the tortuosity characteristic of channelized media, for example, are captured only to a limited extent by linear PCA. With the aim of coupling the kernel-based and weighted methods discussed, we present a novel mathematical formulation of kernel PCA, Weighted Kernel Principal Component Analysis (WKPCA), that both captures nonlinear relationships and incorporates the attribution of significance levels to different realizations of the stochastic random field of interest. We also demonstrate how new instantiations retaining defining characteristics of the random field can be generated using Bayesian methods. In particular, we present a novel WKPCA-based optimization method that minimizes a given objective function with respect to both feature space random variables and observation weights through which optimal snapshot significance levels and optimal features are learned. We showcase how WKPCA can be applied to nonlinear optimal control problems involving channelized media, and in particular demonstrate an application of the method to learning the spatial distribution of material parameter values in the context of linear elasticity, and discuss further extensions of the method to stochastic inversion.
NASA Astrophysics Data System (ADS)
Krishnan, Karthik; Reddy, Kasireddy V.; Ajani, Bhavya; Yalavarthy, Phaneendra K.
2017-02-01
CT and MR perfusion weighted imaging (PWI) enable quantification of perfusion parameters in stroke studies. These parameters are calculated from the residual impulse response function (IRF) based on a physiological model for tissue perfusion. The standard approach for estimating the IRF is deconvolution using oscillatory-limited singular value decomposition (oSVD) or Frequency Domain Deconvolution (FDD). FDD is widely recognized as the fastest approach currently available for deconvolution of CT Perfusion/MR PWI. In this work, three faster methods are proposed. The first is a direct (model based) crude approximation to the final perfusion quantities (Blood flow, Blood volume, Mean Transit Time and Delay) using the Welch-Satterthwaite approximation for gamma fitted concentration time curves (CTC). The second method is a fast accurate deconvolution method, we call Analytical Fourier Filtering (AFF). The third is another fast accurate deconvolution technique using Showalter's method, we call Analytical Showalter's Spectral Filtering (ASSF). Through systematic evaluation on phantom and clinical data, the proposed methods are shown to be computationally more than twice as fast as FDD. The two deconvolution based methods, AFF and ASSF, are also shown to be quantitatively accurate compared to FDD and oSVD.
Pallotta, Arnaud; Philippe, Valentin; Boudier, Ariane; Leroy, Pierre; Clarot, Igor
2018-03-01
A simple isocratic HPLC method using visible detection was developed and validated for the quantification of gold in nanoparticles (AuNP). After a first step of oxidation of nanoparticles, an ion-pair between tetrachloroaurate anion and the cationic dye Rhodamine B was formed and extracted from the aqueous media with the help of an organic solvent. The corresponding Rhodamine B was finally quantified by reversed phase liquid chromatography using a Nucleosil C18 (150mm × 4.6mm, 3µm) column and with a mobile phase containing acetonitrile and 0.1% trifluoroacetic acid aqueous solution (25/75, V/V) at 1.0mLmin -1. and at a wavelength of 555nm. The method was validated using methodology described by the International Conference on Harmonization and was shown to be specific, precise (RSD < 11%), accurate and linear in the range of 0.1 - 30.0µM with a lower limit of quantification (LLOQ) of 0.1µM. This method was in a first time applied to AuNP quality control after their synthesis. In a second time, the absence of gold leakage (either as AuNP or gold salt form) from nanostructured multilayered polyelectrolyte films under shear stress was assessed. Copyright © 2017 Elsevier B.V. All rights reserved.
A RP-HPLC method for quantification of diclofenac sodium released from biological macromolecules.
Bhattacharya, Shiv Sankar; Banerjee, Subham; Ghosh, Ashoke Kumar; Chattopadhyay, Pronobesh; Verma, Anurag; Ghosh, Amitava
2013-07-01
Interpenetrating network (IPN) microbeads of sodium carboxymethyl locust bean gum (SCMLBG) and sodium carboxymethyl cellulose (SCMC) containing diclofenac sodium (DS), a nonsteroidal anti-inflammatory drug, were prepared by single water-in-water (w/w) emulsion gelation process using AlCl3 as cross-linking agent in a complete aqueous environment. Pharmacokinetic study of these IPN microbeads was then carried out by a simple and feasible high-performance liquid chromatographic method with UV detection which was developed and validated for the quantification of diclofenac sodium in rabbit plasma. The chromatographic separation was carried out in a Hypersil BDS, C18 column (250 mm × 4.6 mm; 5 m). The mobile phase was a mixture of acetonitrile and methanol (70:30, v/v) at a flow rate of 1.0 ml/min. The UV detection was set at 276 nm. The extraction recovery of diclofenac sodium in plasma of three quality control (QC) samples was ranged from 81.52% to 95.29%. The calibration curve was linear in the concentration range of 20-1000 ng/ml with the correlation coefficient (r(2)) above 0.9951. The method was specific and sensitive with the limit of quantification of 20 ng/ml. In stability tests, diclofenac sodium in rabbit plasma was stable during storage and assay procedure. Copyright © 2013. Published by Elsevier B.V.
Carraro, R; Dalla Rovere, G; Ferraresso, S; Carraro, L; Franch, R; Toffan, A; Pascoli, F; Patarnello, T; Bargelloni, L
2018-02-01
The availability of a rapid and accurate method for the diagnosis of Photobacterium damselae subsp. piscicida (Phdp), able to discriminate its strictly correlated subsp. damselae (Phdd), formally known as Vibrio damsela, is essential for managing fish pasteurellosis outbreaks in farmed fish. A single-step, high-sensitivity real-time PCR assay for simultaneous detection and quantification of P. damselae was designed targeting partial of the sequence of the bamB gene and tested for specificity and sensitivity on laboratory-generated samples as well as on experimentally infected seabream tissue samples. With a limit of detection (LOD) of one copy in pure bacterial DNA, the sensitivity was higher than all methods previously reported. Validation in target and non-target bacterial species proved the assay was able to discriminate Phdd-Phdp subspecies from diverse hosts/geographical origins and between non-target species. In addition, two SNPs in the target amplicon region determine two distinctive qPCR dissociation curves distinguishing between Phdp-Phdd. This is the first time that a molecular method for P. damselae diagnosis combines detection, quantification and subspecies identification in one step. The assay holds the potential to improve the knowledge of infection dynamics and the development of better strategies to control an important fish disease. © 2017 John Wiley & Sons Ltd.
Ziegler, Jörg; Abel, Steffen
2014-12-01
A new method for the determination of amino acids is presented. It combines established methods for the derivatization of primary and secondary amino groups with 9-fluorenylmethoxycarbonyl chloride (Fmoc-Cl) with the subsequent amino acid specific detection of the derivatives by LC-ESI-MS/MS using multiple reaction monitoring (MRM). The derivatization proceeds within 5 min, and the resulting amino acid derivatives can be rapidly purified from matrix by solid-phase extraction (SPE) on HR-X resin and separated by reversed-phase HPLC. The Fmoc derivatives yield several amino acid specific fragment ions which opened the possibility to select amino acid specific MRM transitions. The method was applied to all 20 proteinogenic amino acids, and the quantification was performed using L-norvaline as standard. A limit of detection as low as 1 fmol/µl with a linear range of up to 125 pmol/µl could be obtained. Intraday and interday precisions were lower than 10 % relative standard deviations for most of the amino acids. Quantification using L-norvaline as internal standard gave very similar results compared to the quantification using deuterated amino acid as internal standards. Using this protocol, it was possible to record the amino acid profiles of only a single root from Arabidopsis thaliana seedlings and to compare it with the amino acid profiles of 20 dissected root meristems (200 μm).
Gao, Jinfang; Cui, Yonghui; Tao, Yanfei; Huang, Lingli; Peng, Dapeng; Xie, Shuyu; Wang, Xu; Liu, Zhenli; Chen, Dongmei; Yuan, Zonghui
2016-11-01
A simple multiresidue method was developed for detecting and quantifying 92 veterinary antimicrobial drugs from eight classes (β-lactams, quinolones, sulfonamides, tetracyclines, lincomycins, macrolides, chloramphenicols, and pleuromutilin) in livestock excreta and water by liquid chromatography with tandem mass spectrometry. The feces samples were extracted by ultrasound-assisted extraction with a mixture of acetonitrile/water (80:20, v/v) and edetate disodium, followed by a cleanup using solid-phase extraction with an amino cartridge. Water samples were purified with hydrophilic-lipophilic balance solid-phase extraction column. Urine samples were extracted with acetonitrile and edetate disodium. Detection of veterinary antimicrobial drugs was achieved by liquid chromatography with tandem mass spectrometry using both positive and negative electrospray ionization mode. The recovery values of veterinary antimicrobial drugs in feces, urine, and water samples were 75-99, 85-110, and 85-101% and associated relative standard deviations were less than 15, 10, and 8%, respectively. The limits of quantification in feces, urine, and water samples were 0.5-1, 0.5-1, and 0.01-0.05 μg/L, respectively. This method was applied to determine real samples obtained from local farms and provides reliable quantification and identification results of 92 veterinary antimicrobial drugs in livestock excreta and water. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Hayashi, Hideki; Kita, Yutaro; Iihara, Hirotoshi; Yanase, Koumei; Ohno, Yasushi; Hirose, Chiemi; Yamada, Maya; Todoroki, Kenichiro; Kitaichi, Kiyoyuki; Minatoguchi, Shinya; Itoh, Yoshinori; Sugiyama, Tadashi
2016-07-01
A simultaneous, selective, sensitive and rapid liquid chromatography/tandem mass spectrometry method was developed and validated for the quantification of gefitinib, erlotinib and afatinib in 250 μL samples of human blood plasma. Diluted plasma samples were extracted using a liquid-phase extraction procedure with tert-butyl methyl ether. The three drugs were separated by high-performance liquid chromatography using a C18 column and an isocratic mobile phase running at a flow rate of 0.2 mL/min for 5 min. The drugs were detected using a tandem mass spectrometer with electrospray ionization using imatinib as an internal standard. Calibration curves were generated over the linear concentration range of 0.05-100 nm in plasma with a lower limit of quantification of 0.01 or 0.05 nm for all compounds. Finally, the validated method was applied to a clinical pharmacokinetic study in patients with nonsmall-cell lung cancer (NSCLC) following the oral administration of afatinib. These results indicate that this method is suitable for assessing the risks and benefits of chemotherapy in patients with NSCLC and is useful for therapeutic drug monitoring for NSCLC treatment. As far as we know, this is the first report on LC-MS/MS method for the simultaneous quantification of NSCLC tyrosine kinase inhibitor plasma concentrations including afatinib. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
Drzymala, Sarah S; Weiz, Stefan; Heinze, Julia; Marten, Silvia; Prinz, Carsten; Zimathies, Annett; Garbe, Leif-Alexander; Koch, Matthias
2015-05-01
Established maximum levels for the mycotoxin zearalenone (ZEN) in edible oil require monitoring by reliable analytical methods. Therefore, an automated SPE-HPLC online system based on dynamic covalent hydrazine chemistry has been developed. The SPE step comprises a reversible hydrazone formation by ZEN and a hydrazine moiety covalently attached to a solid phase. Seven hydrazine materials with different properties regarding the resin backbone, pore size, particle size, specific surface area, and loading have been evaluated. As a result, a hydrazine-functionalized silica gel was chosen. The final automated online method was validated and applied to the analysis of three maize germ oil samples including a provisionally certified reference material. Important performance criteria for the recovery (70-120 %) and precision (RSDr <25 %) as set by the Commission Regulation EC 401/2006 were fulfilled: The mean recovery was 78 % and RSDr did not exceed 8 %. The results of the SPE-HPLC online method were further compared to results obtained by liquid-liquid extraction with stable isotope dilution analysis LC-MS/MS and found to be in good agreement. The developed SPE-HPLC online system with fluorescence detection allows a reliable, accurate, and sensitive quantification (limit of quantification, 30 μg/kg) of ZEN in edible oils while significantly reducing the workload. To our knowledge, this is the first report on an automated SPE-HPLC method based on a covalent SPE approach.
Flow Cytometry: Evolution of Microbiological Methods for Probiotics Enumeration.
Pane, Marco; Allesina, Serena; Amoruso, Angela; Nicola, Stefania; Deidda, Francesca; Mogna, Luca
2018-05-14
The purpose of this trial was to verify that the analytical method ISO 19344:2015 (E)-IDF 232:2015 (E) is valid and reliable for quantifying the concentration of the probiotic Lactobacillus rhamnosus GG (ATCC 53103) in a finished product formulation. Flow cytometry assay is emerging as an alternative rapid method for microbial detection, enumeration, and population profiling. The use of flow cytometry not only permits the determination of viable cell counts but also allows for enumeration of damaged and dead cell subpopulations. Results are expressed as TFU (Total Fluorescent Units) and AFU (Active Fluorescent Units). In December 2015, the International Standard ISO 19344-IDF 232 "Milk and milk products-Starter cultures, probiotics and fermented products-Quantification of lactic acid bacteria by flow cytometry" was published. This particular ISO can be applied universally and regardless of the species of interest. Analytical method validation was conducted on 3 different industrial batches of L. rhamnosus GG according to USP39<1225>/ICH Q2R1 in term of: accuracy, precision (repeatability), intermediate precision (ruggedness), specificity, limit of quantification, linearity, range, robustness. The data obtained on the 3 batches of finished product have significantly demonstrated the validity and robustness of the cytofluorimetric analysis. On the basis of the results obtained, the ISO 19344:2015 (E)-IDF 232:2015 (E) "Quantification of lactic acid bacteria by flow cytometry" can be used for the enumeration of L. rhamnosus GG in a finished product formulation.
Udomsil, Natteewan; Chen, Shu; Rodtong, Sureelak; Yongsawatdigul, Jirawat
2016-08-01
Real-time quantitative polymerase chain reaction (qPCR) methods were developed for the quantification of Virgibacillus sp. SK37 and Tetragenococcus halophilus MS33, which were added as starter cultures in fish sauce fermentation. The PCR assays were coupled with propidium monoazide (PMA) treatment of samples to selectively quantify viable cells and integrated with exogenous recombinant Escherichia coli cells to control variabilities in analysis procedures. The qPCR methods showed species-specificity for both Virgibacillus halodenitrificans and T. halophilus as evaluated using 6 reference strains and 28 strains of bacteria isolated from fish sauce fermentation. The qPCR efficiencies were 101.1% for V. halodenitrificans and 90.2% for T. halophilus. The quantification limits of the assays were 10(3) CFU/mL and 10(2) CFU/mL in fish sauce samples with linear correlations over 4 Logs for V. halodenitrificans and T. halophilus, respectively. The matrix effect was not observed when evaluated using fish sauce samples fermented for 1-6 months. The developed PMA-qPCR methods were successfully applied to monitor changes of Virgibacillus sp. SK37 and T. halophilus MS33 in a mackerel fish sauce fermentation model where culture-dependent techniques failed to quantify the starter cultures. The results demonstrated the usability of the methods as practical tools for monitoring the starter cultures in fish sauce fermentation. Copyright © 2016 Elsevier Ltd. All rights reserved.
Zhao, Xiangsheng; Wei, Jianhe; Yang, Meihua
2018-05-03
Morinda officinalis is an important herbal medicine and functional food, and its main constituents include anthraquinone and iridoid glycosides. Quantification of the main compounds is a necessary step to understand the quality and therapeutic properties of M. officinalis , but this has not yet been performed based on liquid chromatography/tandem mass spectrometry (LC-MS/MS). Analytes were extracted from M. officinalis by reflux method. Ultrahigh-performance liquid chromatography coupled with a triple quadrupole mass spectrometry (UPLC-QqQ-MS) using multiple reaction monitoring (MRM) mode was applied for quantification. Fragmentation pathways of deacetyl asperulosidic acid and rubiadin were investigated based on UPLC with quadrupole time-of-flight tandem mass spectrometry (Q/TOF-MS) in the MS E centroid mode. The method showed a good linearity over a wide concentration range (R² ≥ 0.9930). The limits of quantification of six compounds ranged from 2.6 to 27.57 ng/mL. The intra- and inter-day precisions of the investigated components exhibited an RSD within 4.5% with mean recovery rates of 95.32⁻99.86%. Contents of selected compounds in M. officinalis varied significantly depending on region. The fragmentation pathway of deacetyl asperulosidic and rubiadin was proposed. A selective and sensitive method was developed for determining six target compounds in M. officinalis by UPLC-MS/MS. Furthermore, the proposed method will be helpful for quality control and identification main compounds of M. officinalis .