DOE Office of Scientific and Technical Information (OSTI.GOV)
Abrao, A.
1959-04-01
ABS>Copper and uranium frequently associated in the same mineral, can be qualitatively and quantitatlvely determined by means of the radioisotopes Au/sup 198/ and Np/sup 239/ formed during the irradiation of the mineral in a reactor The copper is separated from the neptunium and fission products by anion resin without the addition of isotopic carriers. The efficiency of the chemical separation and the purity of the two radioisotopes is controlled by gamma spectroscopy and bidetermination of the half lives. (tr-auth)
Studies on magnetocaloric and magnetic coupling effects =
NASA Astrophysics Data System (ADS)
Amaral, Joao Cunha de Sequeira
O presente trabalho apresenta novas metodologias desenvolvidas para a analise das propriedades magneticas e magnetocaloricas de materiais, sustentadas em consideracoes teoricas a partir de modelos, nomeadamente a teoria de transicoes de fase de Landau, o modelo de campo medio molecular e a teoria de fenomeno critico. Sao propostos novos metodos de escala, permitindo a interpretacao de dados de magnetizacao de materiais numa perspectiva de campo medio molecular ou teoria de fenomeno critico. E apresentado um metodo de estimar a magnetizacao espontanea de um material ferromagnetico a partir de relacoes entropia/magnetizacao estabelecidas pelo modelo de campo medio molecular. A termodinamica das transicoes de fase magneticas de primeira ordem e estudada usando a teoria de Landau e de campo medio molecular (modelo de Bean-Rodbell), avaliando os efeitos de fenomenos fora de equilibrio e de condicoes de mistura de fase em estimativas do efeito magnetocalorico a partir de medidas magneticas. Efeitos de desordem, interpretados como uma distribuicao na interaccao magnetica entre ioes, estabelecem os efeitos de distribuicoes quimicas/estruturais nas propriedades magneticas e magnetocaloricas de materiais com transicoes de fase de segunda e de primeira ordem. O uso das metodologias apresentadas na interpretacao das propriedades magneticas de variados materiais ferromagneticos permitiu obter: 1) uma analise quantitativa da variacao de spin por iao Gadolinio devido a transicao estrutural do composto Gd5Si2Ge2, 2) a descricao da configuracao de cluster magnetico de ioes Mn na fase ferromagnetica em manganites da familia La-Sr e La-Ca, 3) a determinacao dos expoentes criticos β e δ do Niquel por metodos de escala, 4) a descricao do efeito da pressao nas propriedades magneticas e magnetocaloricas do composto LaFe11.5Si1.5 atraves do modelo de Bean-Rodbell, 5) uma estimativa da desordem em manganites ferromagneticas com transicoes de segunda e primeira ordem, 6) uma descricao de campo medio das propriedades magneticas da liga Fe23Cu77, 7) o estudo de efeitos de separacao de fase na familia de compostos La0.70-xErxSr0.30MnO3 e 8) a determinacao realista da variacao de entropia magnetica na familia de compostos de efeito magnetocalorico colossal Mn1-x-yFexCryAs.
How to test validity in orthodontic research: a mixed dentition analysis example.
Donatelli, Richard E; Lee, Shin-Jae
2015-02-01
The data used to test the validity of a prediction method should be different from the data used to generate the prediction model. In this study, we explored whether an independent data set is mandatory for testing the validity of a new prediction method and how validity can be tested without independent new data. Several validation methods were compared in an example using the data from a mixed dentition analysis with a regression model. The validation errors of real mixed dentition analysis data and simulation data were analyzed for increasingly large data sets. The validation results of both the real and the simulation studies demonstrated that the leave-1-out cross-validation method had the smallest errors. The largest errors occurred in the traditional simple validation method. The differences between the validation methods diminished as the sample size increased. The leave-1-out cross-validation method seems to be an optimal validation method for improving the prediction accuracy in a data set with limited sample sizes. Copyright © 2015 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
Validation of alternative methods for toxicity testing.
Bruner, L H; Carr, G J; Curren, R D; Chamberlain, M
1998-01-01
Before nonanimal toxicity tests may be officially accepted by regulatory agencies, it is generally agreed that the validity of the new methods must be demonstrated in an independent, scientifically sound validation program. Validation has been defined as the demonstration of the reliability and relevance of a test method for a particular purpose. This paper provides a brief review of the development of the theoretical aspects of the validation process and updates current thinking about objectively testing the performance of an alternative method in a validation study. Validation of alternative methods for eye irritation testing is a specific example illustrating important concepts. Although discussion focuses on the validation of alternative methods intended to replace current in vivo toxicity tests, the procedures can be used to assess the performance of alternative methods intended for other uses. Images Figure 1 PMID:9599695
Analytical difficulties facing today's regulatory laboratories: issues in method validation.
MacNeil, James D
2012-08-01
The challenges facing analytical laboratories today are not unlike those faced in the past, although both the degree of complexity and the rate of change have increased. Challenges such as development and maintenance of expertise, maintenance and up-dating of equipment, and the introduction of new test methods have always been familiar themes for analytical laboratories, but international guidelines for laboratories involved in the import and export testing of food require management of such changes in a context which includes quality assurance, accreditation, and method validation considerations. Decisions as to when a change in a method requires re-validation of the method or on the design of a validation scheme for a complex multi-residue method require a well-considered strategy, based on a current knowledge of international guidance documents and regulatory requirements, as well the laboratory's quality system requirements. Validation demonstrates that a method is 'fit for purpose', so the requirement for validation should be assessed in terms of the intended use of a method and, in the case of change or modification of a method, whether that change or modification may affect a previously validated performance characteristic. In general, method validation involves method scope, calibration-related parameters, method precision, and recovery. Any method change which may affect method scope or any performance parameters will require re-validation. Some typical situations involving change in methods are discussed and a decision process proposed for selection of appropriate validation measures. © 2012 John Wiley & Sons, Ltd.
Bibliometrics for Social Validation.
Hicks, Daniel J
2016-01-01
This paper introduces a bibliometric, citation network-based method for assessing the social validation of novel research, and applies this method to the development of high-throughput toxicology research at the US Environmental Protection Agency. Social validation refers to the acceptance of novel research methods by a relevant scientific community; it is formally independent of the technical validation of methods, and is frequently studied in history, philosophy, and social studies of science using qualitative methods. The quantitative methods introduced here find that high-throughput toxicology methods are spread throughout a large and well-connected research community, which suggests high social validation. Further assessment of social validation involving mixed qualitative and quantitative methods are discussed in the conclusion.
Bibliometrics for Social Validation
2016-01-01
This paper introduces a bibliometric, citation network-based method for assessing the social validation of novel research, and applies this method to the development of high-throughput toxicology research at the US Environmental Protection Agency. Social validation refers to the acceptance of novel research methods by a relevant scientific community; it is formally independent of the technical validation of methods, and is frequently studied in history, philosophy, and social studies of science using qualitative methods. The quantitative methods introduced here find that high-throughput toxicology methods are spread throughout a large and well-connected research community, which suggests high social validation. Further assessment of social validation involving mixed qualitative and quantitative methods are discussed in the conclusion. PMID:28005974
Hess, Cornelius; Sydow, Konrad; Kueting, Theresa; Kraemer, Michael; Maas, Alexandra
2018-02-01
The requirement for correct evaluation of forensic toxicological results in daily routine work and scientific studies is reliable analytical data based on validated methods. Validation of a method gives the analyst tools to estimate the efficacy and reliability of the analytical method. Without validation, data might be contested in court and lead to unjustified legal consequences for a defendant. Therefore, new analytical methods to be used in forensic toxicology require careful method development and validation of the final method. Until now, there are no publications on the validation of chromatographic mass spectrometric methods for the detection of endogenous substances although endogenous analytes can be important in Forensic Toxicology (alcohol consumption marker, congener alcohols, gamma hydroxy butyric acid, human insulin and C-peptide, creatinine, postmortal clinical parameters). For these analytes, conventional validation instructions cannot be followed completely. In this paper, important practical considerations in analytical method validation for endogenous substances will be discussed which may be used as guidance for scientists wishing to develop and validate analytical methods for analytes produced naturally in the human body. Especially the validation parameters calibration model, analytical limits, accuracy (bias and precision) and matrix effects and recovery have to be approached differently. Highest attention should be paid to selectivity experiments. Copyright © 2017 Elsevier B.V. All rights reserved.
78 FR 56718 - Draft Guidance for Industry on Bioanalytical Method Validation; Availability
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-13
...] Draft Guidance for Industry on Bioanalytical Method Validation; Availability AGENCY: Food and Drug... availability of a draft guidance for industry entitled ``Bioanalytical Method Validation.'' The draft guidance is intended to provide recommendations regarding analytical method development and validation for the...
Gaudin, Valérie
2017-09-01
Screening methods are used as a first-line approach to detect the presence of antibiotic residues in food of animal origin. The validation process guarantees that the method is fit-for-purpose, suited to regulatory requirements, and provides evidence of its performance. This article is focused on intra-laboratory validation. The first step in validation is characterisation of performance, and the second step is the validation itself with regard to pre-established criteria. The validation approaches can be absolute (a single method) or relative (comparison of methods), overall (combination of several characteristics in one) or criterion-by-criterion. Various approaches to validation, in the form of regulations, guidelines or standards, are presented and discussed to draw conclusions on their potential application for different residue screening methods, and to determine whether or not they reach the same conclusions. The approach by comparison of methods is not suitable for screening methods for antibiotic residues. The overall approaches, such as probability of detection (POD) and accuracy profile, are increasingly used in other fields of application. They may be of interest for screening methods for antibiotic residues. Finally, the criterion-by-criterion approach (Decision 2002/657/EC and of European guideline for the validation of screening methods), usually applied to the screening methods for antibiotic residues, introduced a major characteristic and an improvement in the validation, i.e. the detection capability (CCβ). In conclusion, screening methods are constantly evolving, thanks to the development of new biosensors or liquid chromatography coupled to tandem-mass spectrometry (LC-MS/MS) methods. There have been clear changes in validation approaches these last 20 years. Continued progress is required and perspectives for future development of guidelines, regulations and standards for validation are presented here.
Shirasaki, Osamu; Asou, Yosuke; Takahashi, Yukio
2007-12-01
Owing to fast or stepwise cuff deflation, or measuring at places other than the upper arm, the clinical accuracy of most recent automated sphygmomanometers (auto-BPMs) cannot be validated by one-arm simultaneous comparison, which would be the only accurate validation method based on auscultation. Two main alternative methods are provided by current standards, that is, two-arm simultaneous comparison (method 1) and one-arm sequential comparison (method 2); however, the accuracy of these validation methods might not be sufficient to compensate for the suspicious accuracy in lateral blood pressure (BP) differences (LD) and/or BP variations (BPV) between the device and reference readings. Thus, the Japan ISO-WG for sphygmomanometer standards has been studying a new method that might improve validation accuracy (method 3). The purpose of this study is to determine the appropriateness of method 3 by comparing immunity to LD and BPV with those of the current validation methods (methods 1 and 2). The validation accuracy of the above three methods was assessed in human participants [N=120, 45+/-15.3 years (mean+/-SD)]. An oscillometric automated monitor, Omron HEM-762, was used as the tested device. When compared with the others, methods 1 and 3 showed a smaller intra-individual standard deviation of device error (SD1), suggesting their higher reproducibility of validation. The SD1 by method 2 (P=0.004) significantly correlated with the participant's BP, supporting our hypothesis that the increased SD of device error by method 2 is at least partially caused by essential BPV. Method 3 showed a significantly (P=0.0044) smaller interparticipant SD of device error (SD2), suggesting its higher interparticipant consistency of validation. Among the methods of validation of the clinical accuracy of auto-BPMs, method 3, which showed the highest reproducibility and highest interparticipant consistency, can be proposed as being the most appropriate.
The Importance of Method Selection in Determining Product Integrity for Nutrition Research1234
Mudge, Elizabeth M; Brown, Paula N
2016-01-01
The American Herbal Products Association estimates that there as many as 3000 plant species in commerce. The FDA estimates that there are about 85,000 dietary supplement products in the marketplace. The pace of product innovation far exceeds that of analytical methods development and validation, with new ingredients, matrixes, and combinations resulting in an analytical community that has been unable to keep up. This has led to a lack of validated analytical methods for dietary supplements and to inappropriate method selection where methods do exist. Only after rigorous validation procedures to ensure that methods are fit for purpose should they be used in a routine setting to verify product authenticity and quality. By following systematic procedures and establishing performance requirements for analytical methods before method development and validation, methods can be developed that are both valid and fit for purpose. This review summarizes advances in method selection, development, and validation regarding herbal supplement analysis and provides several documented examples of inappropriate method selection and application. PMID:26980823
The Importance of Method Selection in Determining Product Integrity for Nutrition Research.
Mudge, Elizabeth M; Betz, Joseph M; Brown, Paula N
2016-03-01
The American Herbal Products Association estimates that there as many as 3000 plant species in commerce. The FDA estimates that there are about 85,000 dietary supplement products in the marketplace. The pace of product innovation far exceeds that of analytical methods development and validation, with new ingredients, matrixes, and combinations resulting in an analytical community that has been unable to keep up. This has led to a lack of validated analytical methods for dietary supplements and to inappropriate method selection where methods do exist. Only after rigorous validation procedures to ensure that methods are fit for purpose should they be used in a routine setting to verify product authenticity and quality. By following systematic procedures and establishing performance requirements for analytical methods before method development and validation, methods can be developed that are both valid and fit for purpose. This review summarizes advances in method selection, development, and validation regarding herbal supplement analysis and provides several documented examples of inappropriate method selection and application. © 2016 American Society for Nutrition.
NASA Astrophysics Data System (ADS)
Herrera-Basurto, R.; Mercader-Trejo, F.; Muñoz-Madrigal, N.; Juárez-García, J. M.; Rodriguez-López, A.; Manzano-Ramírez, A.
2016-07-01
The main goal of method validation is to demonstrate that the method is suitable for its intended purpose. One of the advantages of analytical method validation is translated into a level of confidence about the measurement results reported to satisfy a specific objective. Elemental composition determination by wavelength dispersive spectrometer (WDS) microanalysis has been used over extremely wide areas, mainly in the field of materials science, impurity determinations in geological, biological and food samples. However, little information is reported about the validation of the applied methods. Herein, results of the in-house method validation for elemental composition determination by WDS are shown. SRM 482, a binary alloy Cu-Au of different compositions, was used during the validation protocol following the recommendations for method validation proposed by Eurachem. This paper can be taken as a reference for the evaluation of the validation parameters more frequently requested to get the accreditation under the requirements of the ISO/IEC 17025 standard: selectivity, limit of detection, linear interval, sensitivity, precision, trueness and uncertainty. A model for uncertainty estimation was proposed including systematic and random errors. In addition, parameters evaluated during the validation process were also considered as part of the uncertainty model.
Corvi, Raffaella; Ahr, Hans-Jürgen; Albertini, Silvio; Blakey, David H.; Clerici, Libero; Coecke, Sandra; Douglas, George R.; Gribaldo, Laura; Groten, John P.; Haase, Bernd; Hamernik, Karen; Hartung, Thomas; Inoue, Tohru; Indans, Ian; Maurici, Daniela; Orphanides, George; Rembges, Diana; Sansone, Susanna-Assunta; Snape, Jason R.; Toda, Eisaku; Tong, Weida; van Delft, Joost H.; Weis, Brenda; Schechtman, Leonard M.
2006-01-01
This is the report of the first workshop “Validation of Toxicogenomics-Based Test Systems” held 11–12 December 2003 in Ispra, Italy. The workshop was hosted by the European Centre for the Validation of Alternative Methods (ECVAM) and organized jointly by ECVAM, the U.S. Interagency Coordinating Committee on the Validation of Alternative Methods (ICCVAM), and the National Toxicology Program (NTP) Interagency Center for the Evaluation of Alternative Toxicological Methods (NICEATM). The primary aim of the workshop was for participants to discuss and define principles applicable to the validation of toxicogenomics platforms as well as validation of specific toxicologic test methods that incorporate toxicogenomics technologies. The workshop was viewed as an opportunity for initiating a dialogue between technologic experts, regulators, and the principal validation bodies and for identifying those factors to which the validation process would be applicable. It was felt that to do so now, as the technology is evolving and associated challenges are identified, would be a basis for the future validation of the technology when it reaches the appropriate stage. Because of the complexity of the issue, different aspects of the validation of toxicogenomics-based test methods were covered. The three focus areas include a) biologic validation of toxicogenomics-based test methods for regulatory decision making, b) technical and bioinformatics aspects related to validation, and c) validation issues as they relate to regulatory acceptance and use of toxicogenomics-based test methods. In this report we summarize the discussions and describe in detail the recommendations for future direction and priorities. PMID:16507466
Corvi, Raffaella; Ahr, Hans-Jürgen; Albertini, Silvio; Blakey, David H; Clerici, Libero; Coecke, Sandra; Douglas, George R; Gribaldo, Laura; Groten, John P; Haase, Bernd; Hamernik, Karen; Hartung, Thomas; Inoue, Tohru; Indans, Ian; Maurici, Daniela; Orphanides, George; Rembges, Diana; Sansone, Susanna-Assunta; Snape, Jason R; Toda, Eisaku; Tong, Weida; van Delft, Joost H; Weis, Brenda; Schechtman, Leonard M
2006-03-01
This is the report of the first workshop "Validation of Toxicogenomics-Based Test Systems" held 11-12 December 2003 in Ispra, Italy. The workshop was hosted by the European Centre for the Validation of Alternative Methods (ECVAM) and organized jointly by ECVAM, the U.S. Interagency Coordinating Committee on the Validation of Alternative Methods (ICCVAM), and the National Toxicology Program (NTP) Interagency Center for the Evaluation of Alternative Toxicological Methods (NICEATM). The primary aim of the workshop was for participants to discuss and define principles applicable to the validation of toxicogenomics platforms as well as validation of specific toxicologic test methods that incorporate toxicogenomics technologies. The workshop was viewed as an opportunity for initiating a dialogue between technologic experts, regulators, and the principal validation bodies and for identifying those factors to which the validation process would be applicable. It was felt that to do so now, as the technology is evolving and associated challenges are identified, would be a basis for the future validation of the technology when it reaches the appropriate stage. Because of the complexity of the issue, different aspects of the validation of toxicogenomics-based test methods were covered. The three focus areas include a) biologic validation of toxicogenomics-based test methods for regulatory decision making, b) technical and bioinformatics aspects related to validation, and c) validation issues as they relate to regulatory acceptance and use of toxicogenomics-based test methods. In this report we summarize the discussions and describe in detail the recommendations for future direction and priorities.
Dubreil, Estelle; Gautier, Sophie; Fourmond, Marie-Pierre; Bessiral, Mélaine; Gaugain, Murielle; Verdon, Eric; Pessel, Dominique
2017-04-01
An approach is described to validate a fast and simple targeted screening method for antibiotic analysis in meat and aquaculture products by LC-MS/MS. The strategy of validation was applied for a panel of 75 antibiotics belonging to different families, i.e., penicillins, cephalosporins, sulfonamides, macrolides, quinolones and phenicols. The samples were extracted once with acetonitrile, concentrated by evaporation and injected into the LC-MS/MS system. The approach chosen for the validation was based on the Community Reference Laboratory (CRL) guidelines for the validation of screening qualitative methods. The aim of the validation was to prove sufficient sensitivity of the method to detect all the targeted antibiotics at the level of interest, generally the maximum residue limit (MRL). A robustness study was also performed to test the influence of different factors. The validation showed that the method is valid to detect and identify 73 antibiotics of the 75 antibiotics studied in meat and aquaculture products at the validation levels.
2017-09-01
VALIDATION OF MODEL UPDATING AND DAMAGE DETECTION VIA EIGENVALUE SENSITIVITY METHODS WITH ARTIFICIAL BOUNDARY CONDITIONS by Matthew D. Bouwense...VALIDATION OF MODEL UPDATING AND DAMAGE DETECTION VIA EIGENVALUE SENSITIVITY METHODS WITH ARTIFICIAL BOUNDARY CONDITIONS 5. FUNDING NUMBERS 6. AUTHOR...unlimited. EXPERIMENTAL VALIDATION OF MODEL UPDATING AND DAMAGE DETECTION VIA EIGENVALUE SENSITIVITY METHODS WITH ARTIFICIAL BOUNDARY
Presgrave, Octavio; Moura, Wlamir; Caldeira, Cristiane; Pereira, Elisabete; Bôas, Maria H Villas; Eskes, Chantra
2016-03-01
The need for the creation of a Brazilian centre for the validation of alternative methods was recognised in 2008, and members of academia, industry and existing international validation centres immediately engaged with the idea. In 2012, co-operation between the Oswaldo Cruz Foundation (FIOCRUZ) and the Brazilian Health Surveillance Agency (ANVISA) instigated the establishment of the Brazilian Center for the Validation of Alternative Methods (BraCVAM), which was officially launched in 2013. The Brazilian validation process follows OECD Guidance Document No. 34, where BraCVAM functions as the focal point to identify and/or receive requests from parties interested in submitting tests for validation. BraCVAM then informs the Brazilian National Network on Alternative Methods (RENaMA) of promising assays, which helps with prioritisation and contributes to the validation studies of selected assays. A Validation Management Group supervises the validation study, and the results obtained are peer-reviewed by an ad hoc Scientific Review Committee, organised under the auspices of BraCVAM. Based on the peer-review outcome, BraCVAM will prepare recommendations on the validated test method, which will be sent to the National Council for the Control of Animal Experimentation (CONCEA). CONCEA is in charge of the regulatory adoption of all validated test methods in Brazil, following an open public consultation. 2016 FRAME.
Likelihood ratio data to report the validation of a forensic fingerprint evaluation method.
Ramos, Daniel; Haraksim, Rudolf; Meuwly, Didier
2017-02-01
Data to which the authors refer to throughout this article are likelihood ratios (LR) computed from the comparison of 5-12 minutiae fingermarks with fingerprints. These LRs data are used for the validation of a likelihood ratio (LR) method in forensic evidence evaluation. These data present a necessary asset for conducting validation experiments when validating LR methods used in forensic evidence evaluation and set up validation reports. These data can be also used as a baseline for comparing the fingermark evidence in the same minutiae configuration as presented in (D. Meuwly, D. Ramos, R. Haraksim,) [1], although the reader should keep in mind that different feature extraction algorithms and different AFIS systems used may produce different LRs values. Moreover, these data may serve as a reproducibility exercise, in order to train the generation of validation reports of forensic methods, according to [1]. Alongside the data, a justification and motivation for the use of methods is given. These methods calculate LRs from the fingerprint/mark data and are subject to a validation procedure. The choice of using real forensic fingerprint in the validation and simulated data in the development is described and justified. Validation criteria are set for the purpose of validation of the LR methods, which are used to calculate the LR values from the data and the validation report. For privacy and data protection reasons, the original fingerprint/mark images cannot be shared. But these images do not constitute the core data for the validation, contrarily to the LRs that are shared.
Wiegers, Ann L
2003-07-01
Third-party accreditation is a valuable tool to demonstrate a laboratory's competence to conduct testing. Accreditation, internationally and in the United States, has been discussed previously. However, accreditation is only I part of establishing data credibility. A validated test method is the first component of a valid measurement system. Validation is defined as confirmation by examination and the provision of objective evidence that the particular requirements for a specific intended use are fulfilled. The international and national standard ISO/IEC 17025 recognizes the importance of validated methods and requires that laboratory-developed methods or methods adopted by the laboratory be appropriate for the intended use. Validated methods are therefore required and their use agreed to by the client (i.e., end users of the test results such as veterinarians, animal health programs, and owners). ISO/IEC 17025 also requires that the introduction of methods developed by the laboratory for its own use be a planned activity conducted by qualified personnel with adequate resources. This article discusses considerations and recommendations for the conduct of veterinary diagnostic test method development, validation, evaluation, approval, and transfer to the user laboratory in the ISO/IEC 17025 environment. These recommendations are based on those of nationally and internationally accepted standards and guidelines, as well as those of reputable and experienced technical bodies. They are also based on the author's experience in the evaluation of method development and transfer projects, validation data, and the implementation of quality management systems in the area of method development.
Aandstad, Anders; Holtberget, Kristian; Hageberg, Rune; Holme, Ingar; Anderssen, Sigmund A
2014-02-01
Previous studies show that body composition is related to injury risk and physical performance in soldiers. Thus, valid methods for measuring body composition in military personnel are needed. The frequently used body mass index method is not a valid measure of body composition in soldiers, but reliability and validity of alternative field methods are less investigated in military personnel. Thus, we carried out test and retest of skinfold (SKF), single frequency bioelectrical impedance analysis (SF-BIA), and multifrequency bioelectrical impedance analysis measurements in 65 male and female soldiers. Several validated equations were used to predict percent body fat from these methods. Dual-energy X-ray absorptiometry was also measured, and acted as the criterion method. Results showed that SF-BIA was the most reliable method in both genders. In women, SF-BIA was also the most valid method, whereas SKF or a combination of SKF and SF-BIA produced the highest validity in men. Reliability and validity varied substantially among the equations examined. The best methods and equations produced test-retest 95% limits of agreement below ±1% points, whereas the corresponding validity figures were ±3.5% points. Each investigator and practitioner must consider whether such measurement errors are acceptable for its specific use. Reprint & Copyright © 2014 Association of Military Surgeons of the U.S.
AlHeresh, Rawan; LaValley, Michael P; Coster, Wendy; Keysor, Julie J
2017-06-01
To evaluate construct validity and scoring methods of the world health organization-health and work performance questionnaire (HPQ) for people with arthritis. Construct validity was examined through hypothesis testing using the recommended guidelines of the consensus-based standards for the selection of health measurement instruments (COSMIN). The HPQ using the absolute scoring method showed moderate construct validity as four of the seven hypotheses were met. The HPQ using the relative scoring method had weak construct validity as only one of the seven hypotheses were met. The absolute scoring method for the HPQ is superior in construct validity to the relative scoring method in assessing work performance among people with arthritis and related rheumatic conditions; however, more research is needed to further explore other psychometric properties of the HPQ.
Comparative assessment of bioanalytical method validation guidelines for pharmaceutical industry.
Kadian, Naveen; Raju, Kanumuri Siva Rama; Rashid, Mamunur; Malik, Mohd Yaseen; Taneja, Isha; Wahajuddin, Muhammad
2016-07-15
The concepts, importance, and application of bioanalytical method validation have been discussed for a long time and validation of bioanalytical methods is widely accepted as pivotal before they are taken into routine use. United States Food and Drug Administration (USFDA) guidelines issued in 2001 have been referred for every guideline released ever since; may it be European Medical Agency (EMA) Europe, National Health Surveillance Agency (ANVISA) Brazil, Ministry of Health and Labour Welfare (MHLW) Japan or any other guideline in reference to bioanalytical method validation. After 12 years, USFDA released its new draft guideline for comments in 2013, which covers the latest parameters or topics encountered in bioanalytical method validation and approached towards the harmonization of bioanalytical method validation across the globe. Even though the regulatory agencies have general agreement, significant variations exist in acceptance criteria and methodology. The present review highlights the variations, similarities and comparison between bioanalytical method validation guidelines issued by major regulatory authorities worldwide. Additionally, other evaluation parameters such as matrix effect, incurred sample reanalysis including other stability aspects have been discussed to provide an ease of access for designing a bioanalytical method and its validation complying with the majority of drug authority guidelines. Copyright © 2016. Published by Elsevier B.V.
Fuzzy-logic based strategy for validation of multiplex methods: example with qualitative GMO assays.
Bellocchi, Gianni; Bertholet, Vincent; Hamels, Sandrine; Moens, W; Remacle, José; Van den Eede, Guy
2010-02-01
This paper illustrates the advantages that a fuzzy-based aggregation method could bring into the validation of a multiplex method for GMO detection (DualChip GMO kit, Eppendorf). Guidelines for validation of chemical, bio-chemical, pharmaceutical and genetic methods have been developed and ad hoc validation statistics are available and routinely used, for in-house and inter-laboratory testing, and decision-making. Fuzzy logic allows summarising the information obtained by independent validation statistics into one synthetic indicator of overall method performance. The microarray technology, introduced for simultaneous identification of multiple GMOs, poses specific validation issues (patterns of performance for a variety of GMOs at different concentrations). A fuzzy-based indicator for overall evaluation is illustrated in this paper, and applied to validation data for different genetically modified elements. Remarks were drawn on the analytical results. The fuzzy-logic based rules were shown to be applicable to improve interpretation of results and facilitate overall evaluation of the multiplex method.
76 FR 28664 - Method 301-Field Validation of Pollutant Measurement Methods From Various Waste Media
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-18
... ENVIRONMENTAL PROTECTION AGENCY 40 CFR Part 63 [OAR-2004-0080, FRL-9306-8] RIN 2060-AF00 Method 301--Field Validation of Pollutant Measurement Methods From Various Waste Media AGENCY: Environmental Protection Agency (EPA). ACTION: Final rule. SUMMARY: This action amends EPA's Method 301, Field Validation...
Griesinger, Claudius; Desprez, Bertrand; Coecke, Sandra; Casey, Warren; Zuang, Valérie
This chapter explores the concepts, processes, tools and challenges relating to the validation of alternative methods for toxicity and safety testing. In general terms, validation is the process of assessing the appropriateness and usefulness of a tool for its intended purpose. Validation is routinely used in various contexts in science, technology, the manufacturing and services sectors. It serves to assess the fitness-for-purpose of devices, systems, software up to entire methodologies. In the area of toxicity testing, validation plays an indispensable role: "alternative approaches" are increasingly replacing animal models as predictive tools and it needs to be demonstrated that these novel methods are fit for purpose. Alternative approaches include in vitro test methods, non-testing approaches such as predictive computer models up to entire testing and assessment strategies composed of method suites, data sources and decision-aiding tools. Data generated with alternative approaches are ultimately used for decision-making on public health and the protection of the environment. It is therefore essential that the underlying methods and methodologies are thoroughly characterised, assessed and transparently documented through validation studies involving impartial actors. Importantly, validation serves as a filter to ensure that only test methods able to produce data that help to address legislative requirements (e.g. EU's REACH legislation) are accepted as official testing tools and, owing to the globalisation of markets, recognised on international level (e.g. through inclusion in OECD test guidelines). Since validation creates a credible and transparent evidence base on test methods, it provides a quality stamp, supporting companies developing and marketing alternative methods and creating considerable business opportunities. Validation of alternative methods is conducted through scientific studies assessing two key hypotheses, reliability and relevance of the test method for a given purpose. Relevance encapsulates the scientific basis of the test method, its capacity to predict adverse effects in the "target system" (i.e. human health or the environment) as well as its applicability for the intended purpose. In this chapter we focus on the validation of non-animal in vitro alternative testing methods and review the concepts, challenges, processes and tools fundamental to the validation of in vitro methods intended for hazard testing of chemicals. We explore major challenges and peculiarities of validation in this area. Based on the notion that validation per se is a scientific endeavour that needs to adhere to key scientific principles, namely objectivity and appropriate choice of methodology, we examine basic aspects of study design and management, and provide illustrations of statistical approaches to describe predictive performance of validated test methods as well as their reliability.
Software validation applied to spreadsheets used in laboratories working under ISO/IEC 17025
NASA Astrophysics Data System (ADS)
Banegas, J. M.; Orué, M. W.
2016-07-01
Several documents deal with software validation. Nevertheless, more are too complex to be applied to validate spreadsheets - surely the most used software in laboratories working under ISO/IEC 17025. The method proposed in this work is intended to be directly applied to validate spreadsheets. It includes a systematic way to document requirements, operational aspects regarding to validation, and a simple method to keep records of validation results and modifications history. This method is actually being used in an accredited calibration laboratory, showing to be practical and efficient.
Comparative assessment of three standardized robotic surgery training methods.
Hung, Andrew J; Jayaratna, Isuru S; Teruya, Kara; Desai, Mihir M; Gill, Inderbir S; Goh, Alvin C
2013-10-01
To evaluate three standardized robotic surgery training methods, inanimate, virtual reality and in vivo, for their construct validity. To explore the concept of cross-method validity, where the relative performance of each method is compared. Robotic surgical skills were prospectively assessed in 49 participating surgeons who were classified as follows: 'novice/trainee': urology residents, previous experience <30 cases (n = 38) and 'experts': faculty surgeons, previous experience ≥30 cases (n = 11). Three standardized, validated training methods were used: (i) structured inanimate tasks; (ii) virtual reality exercises on the da Vinci Skills Simulator (Intuitive Surgical, Sunnyvale, CA, USA); and (iii) a standardized robotic surgical task in a live porcine model with performance graded by the Global Evaluative Assessment of Robotic Skills (GEARS) tool. A Kruskal-Wallis test was used to evaluate performance differences between novices and experts (construct validity). Spearman's correlation coefficient (ρ) was used to measure the association of performance across inanimate, simulation and in vivo methods (cross-method validity). Novice and expert surgeons had previously performed a median (range) of 0 (0-20) and 300 (30-2000) robotic cases, respectively (P < 0.001). Construct validity: experts consistently outperformed residents with all three methods (P < 0.001). Cross-method validity: overall performance of inanimate tasks significantly correlated with virtual reality robotic performance (ρ = -0.7, P < 0.001) and in vivo robotic performance based on GEARS (ρ = -0.8, P < 0.0001). Virtual reality performance and in vivo tissue performance were also found to be strongly correlated (ρ = 0.6, P < 0.001). We propose the novel concept of cross-method validity, which may provide a method of evaluating the relative value of various forms of skills education and assessment. We externally confirmed the construct validity of each featured training tool. © 2013 BJU International.
Yousuf, Naveed; Violato, Claudio; Zuberi, Rukhsana W
2015-01-01
CONSTRUCT: Authentic standard setting methods will demonstrate high convergent validity evidence of their outcomes, that is, cutoff scores and pass/fail decisions, with most other methods when compared with each other. The objective structured clinical examination (OSCE) was established for valid, reliable, and objective assessment of clinical skills in health professions education. Various standard setting methods have been proposed to identify objective, reliable, and valid cutoff scores on OSCEs. These methods may identify different cutoff scores for the same examinations. Identification of valid and reliable cutoff scores for OSCEs remains an important issue and a challenge. Thirty OSCE stations administered at least twice in the years 2010-2012 to 393 medical students in Years 2 and 3 at Aga Khan University are included. Psychometric properties of the scores are determined. Cutoff scores and pass/fail decisions of Wijnen, Cohen, Mean-1.5SD, Mean-1SD, Angoff, borderline group and borderline regression (BL-R) methods are compared with each other and with three variants of cluster analysis using repeated measures analysis of variance and Cohen's kappa. The mean psychometric indices on the 30 OSCE stations are reliability coefficient = 0.76 (SD = 0.12); standard error of measurement = 5.66 (SD = 1.38); coefficient of determination = 0.47 (SD = 0.19), and intergrade discrimination = 7.19 (SD = 1.89). BL-R and Wijnen methods show the highest convergent validity evidence among other methods on the defined criteria. Angoff and Mean-1.5SD demonstrated least convergent validity evidence. The three cluster variants showed substantial convergent validity with borderline methods. Although there was a high level of convergent validity of Wijnen method, it lacks the theoretical strength to be used for competency-based assessments. The BL-R method is found to show the highest convergent validity evidences for OSCEs with other standard setting methods used in the present study. We also found that cluster analysis using mean method can be used for quality assurance of borderline methods. These findings should be further confirmed by studies in other settings.
An Engineering Method of Civil Jet Requirements Validation Based on Requirements Project Principle
NASA Astrophysics Data System (ADS)
Wang, Yue; Gao, Dan; Mao, Xuming
2018-03-01
A method of requirements validation is developed and defined to meet the needs of civil jet requirements validation in product development. Based on requirements project principle, this method will not affect the conventional design elements, and can effectively connect the requirements with design. It realizes the modern civil jet development concept, which is “requirement is the origin, design is the basis”. So far, the method has been successfully applied in civil jet aircraft development in China. Taking takeoff field length as an example, the validation process and the validation method of the requirements are detailed introduced in the study, with the hope of providing the experiences to other civil jet product design.
ERIC Educational Resources Information Center
Nicklas, Theresa A.; O'Neil, Carol E.; Stuff, Janice; Goodell, Lora Suzanne; Liu, Yan; Martin, Corby K.
2012-01-01
Objective: The goal of the study was to assess the validity and feasibility of a digital diet estimation method for use with preschool children in "Head Start." Methods: Preschool children and their caregivers participated in validation (n = 22) and feasibility (n = 24) pilot studies. Validity was determined in the metabolic research unit using…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ekechukwu, A.
This document proposes to provide a listing of available sources which can be used to validate analytical methods and/or instrumentation for beryllium determination. A literature review was conducted of available standard methods and publications used for method validation and/or quality control. A comprehensive listing of the articles, papers, and books reviewed is given in Appendix 1. Available validation documents and guides are listed in the appendix; each has a brief description of application and use. In the referenced sources, there are varying approaches to validation and varying descriptions of validation at different stages in method development. This discussion focuses onmore » validation and verification of fully developed methods and instrumentation that have been offered up for use or approval by other laboratories or official consensus bodies such as ASTM International, the International Standards Organization (ISO) and the Association of Official Analytical Chemists (AOAC). This review was conducted as part of a collaborative effort to investigate and improve the state of validation for measuring beryllium in the workplace and the environment. Documents and publications from the United States and Europe are included. Unless otherwise specified, all documents were published in English.« less
Gourmelon, Anne; Delrue, Nathalie
Ten years elapsed since the OECD published the Guidance document on the validation and international regulatory acceptance of test methods for hazard assessment. Much experience has been gained since then in validation centres, in countries and at the OECD on a variety of test methods that were subjected to validation studies. This chapter reviews validation principles and highlights common features that appear to be important for further regulatory acceptance across studies. Existing OECD-agreed validation principles will most likely generally remain relevant and applicable to address challenges associated with the validation of future test methods. Some adaptations may be needed to take into account the level of technique introduced in test systems, but demonstration of relevance and reliability will continue to play a central role as pre-requisite for the regulatory acceptance. Demonstration of relevance will become more challenging for test methods that form part of a set of predictive tools and methods, and that do not stand alone. OECD is keen on ensuring that while these concepts evolve, countries can continue to rely on valid methods and harmonised approaches for an efficient testing and assessment of chemicals.
Toward a Unified Validation Framework in Mixed Methods Research
ERIC Educational Resources Information Center
Dellinger, Amy B.; Leech, Nancy L.
2007-01-01
The primary purpose of this article is to further discussions of validity in mixed methods research by introducing a validation framework to guide thinking about validity in this area. To justify the use of this framework, the authors discuss traditional terminology and validity criteria for quantitative and qualitative research, as well as…
Fachi, Mariana Millan; Leonart, Letícia Paula; Cerqueira, Letícia Bonancio; Pontes, Flavia Lada Degaut; de Campos, Michel Leandro; Pontarolo, Roberto
2017-06-15
A systematic and critical review was conducted on bioanalytical methods validated to quantify combinations of antidiabetic agents in human blood. The aim of this article was to verify how the validation process of bioanalytical methods is performed and the quality of the published records. The validation assays were evaluated according to international guidelines. The main problems in the validation process are pointed out and discussed to help researchers to choose methods that are truly reliable and can be successfully applied for their intended use. The combination of oral antidiabetic agents was chosen as these are some of the most studied drugs and several methods are present in the literature. Moreover, this article may be applied to the validation process of all bioanalytical. Copyright © 2017 Elsevier B.V. All rights reserved.
Validation studies and proficiency testing.
Ankilam, Elke; Heinze, Petra; Kay, Simon; Van den Eede, Guy; Popping, Bert
2002-01-01
Genetically modified organisms (GMOs) entered the European food market in 1996. Current legislation demands the labeling of food products if they contain <1% GMO, as assessed for each ingredient of the product. To create confidence in the testing methods and to complement enforcement requirements, there is an urgent need for internationally validated methods, which could serve as reference methods. To date, several methods have been submitted to validation trials at an international level; approaches now exist that can be used in different circumstances and for different food matrixes. Moreover, the requirement for the formal validation of methods is clearly accepted; several national and international bodies are active in organizing studies. Further validation studies, especially on the quantitative polymerase chain reaction methods, need to be performed to cover the rising demand for new extraction methods and other background matrixes, as well as for novel GMO constructs.
78 FR 20695 - Walk-Through Metal Detectors and Hand-Held Metal Detectors Test Method Validation
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-05
... Detectors and Hand-Held Metal Detectors Test Method Validation AGENCY: National Institute of Justice, DOJ... ensure that the test methods in the standards are properly documented, NIJ is requesting proposals (including price quotes) for test method validation efforts from testing laboratories. NIJ is also seeking...
Validity in Mixed Methods Research in Education: The Application of Habermas' Critical Theory
ERIC Educational Resources Information Center
Long, Haiying
2017-01-01
Mixed methods approach has developed into the third methodological movement in educational research. Validity in mixed methods research as an important issue, however, has not been examined as extensively as that of quantitative and qualitative research. Additionally, the previous discussions of validity in mixed methods research focus on research…
Task Validation for the AN/TPQ-36 Radar System
1978-09-01
report presents the method and results of a study to validate personnel task descriptions for the new AN/TyP-Jb radar...TP.J-Sb KAPAK SVSTKM CONTENTS i ■ l.t |i- INTRODUCTION t METHOD 2 RESULTS, CONCLUSIONS, AND RECOMMENDATIONS b Task Validation 5 26B MOS... method , results, conclusions, and recommendations of the validation study. The appendixes contain the following: 1. Appendix A contains
How Many Batches Are Needed for Process Validation under the New FDA Guidance?
Yang, Harry
2013-01-01
The newly updated FDA Guidance for Industry on Process Validation: General Principles and Practices ushers in a life cycle approach to process validation. While the guidance no longer considers the use of traditional three-batch validation appropriate, it does not prescribe the number of validation batches for a prospective validation protocol, nor does it provide specific methods to determine it. This potentially could leave manufacturers in a quandary. In this paper, I develop a Bayesian method to address the issue. By combining process knowledge gained from Stage 1 Process Design (PD) with expected outcomes of Stage 2 Process Performance Qualification (PPQ), the number of validation batches for PPQ is determined to provide a high level of assurance that the process will consistently produce future batches meeting quality standards. Several examples based on simulated data are presented to illustrate the use of the Bayesian method in helping manufacturers make risk-based decisions for Stage 2 PPQ, and they highlight the advantages of the method over traditional Frequentist approaches. The discussions in the paper lend support for a life cycle and risk-based approach to process validation recommended in the new FDA guidance. The newly updated FDA Guidance for Industry on Process Validation: General Principles and Practices ushers in a life cycle approach to process validation. While the guidance no longer considers the use of traditional three-batch validation appropriate, it does not prescribe the number of validation batches for a prospective validation protocol, nor does it provide specific methods to determine it. This potentially could leave manufacturers in a quandary. In this paper, I develop a Bayesian method to address the issue. By combining process knowledge gained from Stage 1 Process Design (PD) with expected outcomes of Stage 2 Process Performance Qualification (PPQ), the number of validation batches for PPQ is determined to provide a high level of assurance that the process will consistently produce future batches meeting quality standards. Several examples based on simulated data are presented to illustrate the use of the Bayesian method in helping manufacturers make risk-based decisions for Stage 2 PPQ, and THEY highlight the advantages of the method over traditional Frequentist approaches. The discussions in the paper lend support for a life cycle and risk-based approach to process validation recommended in the new FDA guidance.
Random Qualitative Validation: A Mixed-Methods Approach to Survey Validation
ERIC Educational Resources Information Center
Van Duzer, Eric
2012-01-01
The purpose of this paper is to introduce the process and value of Random Qualitative Validation (RQV) in the development and interpretation of survey data. RQV is a method of gathering clarifying qualitative data that improves the validity of the quantitative analysis. This paper is concerned with validity in relation to the participants'…
Content validity across methods of malnutrition assessment in patients with cancer is limited.
Sealy, Martine J; Nijholt, Willemke; Stuiver, Martijn M; van der Berg, Marit M; Roodenburg, Jan L N; van der Schans, Cees P; Ottery, Faith D; Jager-Wittenaar, Harriët
2016-08-01
To identify malnutrition assessment methods in cancer patients and assess their content validity based on internationally accepted definitions for malnutrition. Systematic review of studies in cancer patients that operationalized malnutrition as a variable, published since 1998. Eleven key concepts, within the three domains reflected by the malnutrition definitions acknowledged by European Society for Clinical Nutrition and Metabolism (ESPEN) and the American Society for Parenteral and Enteral Nutrition (ASPEN): A: nutrient balance; B: changes in body shape, body area and body composition; and C: function, were used to classify content validity of methods to assess malnutrition. Content validity indices (M-CVIA-C) were calculated per assessment method. Acceptable content validity was defined as M-CVIA-C ≥ 0.80. Thirty-seven assessment methods were identified in the 160 included articles. Mini Nutritional Assessment (M-CVIA-C = 0.72), Scored Patient-Generated Subjective Global Assessment (M-CVIA-C = 0.61), and Subjective Global Assessment (M-CVIA-C = 0.53) scored highest M-CVIA-C. A large number of malnutrition assessment methods are used in cancer research. Content validity of these methods varies widely. None of these assessment methods has acceptable content validity, when compared against a construct based on ESPEN and ASPEN definitions of malnutrition. Copyright © 2016 Elsevier Inc. All rights reserved.
Field validation of the dnph method for aldehydes and ketones. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Workman, G.S.; Steger, J.L.
1996-04-01
A stationary source emission test method for selected aldehydes and ketones has been validated. The method employs a sampling train with impingers containing 2,4-dinitrophenylhydrazine (DNPH) to derivatize the analytes. The resulting hydrazones are recovered and analyzed by high performance liquid chromatography. Nine analytes were studied; the method was validated for formaldehyde, acetaldehyde, propionaldehyde, acetophenone and isophorone. Acrolein, menthyl ethyl ketone, menthyl isobutyl ketone, and quinone did not meet the validation criteria. The study employed the validation techniques described in EPA method 301, which uses train spiking to determine bias, and collocated sampling trains to determine precision. The studies were carriedmore » out at a plywood veneer dryer and a polyester manufacturing plant.« less
ERIC Educational Resources Information Center
Ember, Lois R.
1977-01-01
The procedures utilized by the Association of Official Analytical Chemists (AOAC) to develop, evaluate, and validate analytical methods for the analysis of chemical pollutants are detailed. Methods validated by AOAC are used by the EPA and FDA in their enforcement programs and are granted preferential treatment by the courts. (BT)
A guideline for the validation of likelihood ratio methods used for forensic evidence evaluation.
Meuwly, Didier; Ramos, Daniel; Haraksim, Rudolf
2017-07-01
This Guideline proposes a protocol for the validation of forensic evaluation methods at the source level, using the Likelihood Ratio framework as defined within the Bayes' inference model. In the context of the inference of identity of source, the Likelihood Ratio is used to evaluate the strength of the evidence for a trace specimen, e.g. a fingermark, and a reference specimen, e.g. a fingerprint, to originate from common or different sources. Some theoretical aspects of probabilities necessary for this Guideline were discussed prior to its elaboration, which started after a workshop of forensic researchers and practitioners involved in this topic. In the workshop, the following questions were addressed: "which aspects of a forensic evaluation scenario need to be validated?", "what is the role of the LR as part of a decision process?" and "how to deal with uncertainty in the LR calculation?". The questions: "what to validate?" focuses on the validation methods and criteria and "how to validate?" deals with the implementation of the validation protocol. Answers to these questions were deemed necessary with several objectives. First, concepts typical for validation standards [1], such as performance characteristics, performance metrics and validation criteria, will be adapted or applied by analogy to the LR framework. Second, a validation strategy will be defined. Third, validation methods will be described. Finally, a validation protocol and an example of validation report will be proposed, which can be applied to the forensic fields developing and validating LR methods for the evaluation of the strength of evidence at source level under the following propositions. Copyright © 2016. Published by Elsevier B.V.
Nelson, Jennifer Clark; Marsh, Tracey; Lumley, Thomas; Larson, Eric B; Jackson, Lisa A; Jackson, Michael L
2013-08-01
Estimates of treatment effectiveness in epidemiologic studies using large observational health care databases may be biased owing to inaccurate or incomplete information on important confounders. Study methods that collect and incorporate more comprehensive confounder data on a validation cohort may reduce confounding bias. We applied two such methods, namely imputation and reweighting, to Group Health administrative data (full sample) supplemented by more detailed confounder data from the Adult Changes in Thought study (validation sample). We used influenza vaccination effectiveness (with an unexposed comparator group) as an example and evaluated each method's ability to reduce bias using the control time period before influenza circulation. Both methods reduced, but did not completely eliminate, the bias compared with traditional effectiveness estimates that do not use the validation sample confounders. Although these results support the use of validation sampling methods to improve the accuracy of comparative effectiveness findings from health care database studies, they also illustrate that the success of such methods depends on many factors, including the ability to measure important confounders in a representative and large enough validation sample, the comparability of the full sample and validation sample, and the accuracy with which the data can be imputed or reweighted using the additional validation sample information. Copyright © 2013 Elsevier Inc. All rights reserved.
Uno, Yoshifumi; Kojima, Hajime; Omori, Takashi; Corvi, Raffaella; Honma, Masamistu; Schechtman, Leonard M; Tice, Raymond R; Burlinson, Brian; Escobar, Patricia A; Kraynak, Andrew R; Nakagawa, Yuzuki; Nakajima, Madoka; Pant, Kamala; Asano, Norihide; Lovell, David; Morita, Takeshi; Ohno, Yasuo; Hayashi, Makoto
2015-07-01
The in vivo rodent alkaline comet assay (comet assay) is used internationally to investigate the in vivo genotoxic potential of test chemicals. This assay, however, has not previously been formally validated. The Japanese Center for the Validation of Alternative Methods (JaCVAM), with the cooperation of the U.S. NTP Interagency Center for the Evaluation of Alternative Toxicological Methods (NICEATM)/the Interagency Coordinating Committee on the Validation of Alternative Methods (ICCVAM), the European Centre for the Validation of Alternative Methods (ECVAM), and the Japanese Environmental Mutagen Society/Mammalian Mutagenesis Study Group (JEMS/MMS), organized an international validation study to evaluate the reliability and relevance of the assay for identifying genotoxic carcinogens, using liver and stomach as target organs. The ultimate goal of this validation effort was to establish an Organisation for Economic Co-operation and Development (OECD) test guideline. The purpose of the pre-validation studies (i.e., Phase 1 through 3), conducted in four or five laboratories with extensive comet assay experience, was to optimize the protocol to be used during the definitive validation study. Copyright © 2015 Elsevier B.V. All rights reserved.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-13
... Committee on the Validation of Alternative Methods (ICCVAM) AGENCY: Division of the National Toxicology... Alternative Toxicological Methods (NICEATM) announces the availability of the Biennial Progress Report 2010-2011: Interagency Coordinating Committee on the Validation of Alternative Methods. The report was...
Feldsine, Philip; Kaur, Mandeep; Shah, Khyati; Immerman, Amy; Jucker, Markus; Lienau, Andrew
2015-01-01
Assurance GDSTM for Salmonella Tq has been validated according to the AOAC INTERNATIONAL Methods Committee Guidelines for Validation of Microbiological Methods for Food and Environmental Surfaces for the detection of selected foods and environmental surfaces (Official Method of AnalysisSM 2009.03, Performance Tested MethodSM No. 050602). The method also completed AFNOR validation (following the ISO 16140 standard) compared to the reference method EN ISO 6579. For AFNOR, GDS was given a scope covering all human food, animal feed stuff, and environmental surfaces (Certificate No. TRA02/12-01/09). Results showed that Assurance GDS for Salmonella (GDS) has high sensitivity and is equivalent to the reference culture methods for the detection of motile and non-motile Salmonella. As part of the aforementioned validations, inclusivity and exclusivity studies, stability, and ruggedness studies were also conducted. Assurance GDS has 100% inclusivity and exclusivity among the 100 Salmonella serovars and 35 non-Salmonella organisms analyzed. To add to the scope of the Assurance GDS for Salmonella method, a matrix extension study was conducted, following the AOAC guidelines, to validate the application of the method for selected spices, specifically curry powder, cumin powder, and chili powder, for the detection of Salmonella.
Reliability and validity of the AutoCAD software method in lumbar lordosis measurement
Letafatkar, Amir; Amirsasan, Ramin; Abdolvahabi, Zahra; Hadadnezhad, Malihe
2011-01-01
Objective The aim of this study was to determine the reliability and validity of the AutoCAD software method in lumbar lordosis measurement. Methods Fifty healthy volunteers with a mean age of 23 ± 1.80 years were enrolled. A lumbar lateral radiograph was taken on all participants, and the lordosis was measured according to the Cobb method. Afterward, the lumbar lordosis degree was measured via AutoCAD software and flexible ruler methods. The current study is accomplished in 2 parts: intratester and intertester evaluations of reliability as well as the validity of the flexible ruler and software methods. Results Based on the intraclass correlation coefficient, AutoCAD's reliability and validity in measuring lumbar lordosis were 0.984 and 0.962, respectively. Conclusions AutoCAD showed to be a reliable and valid method to measure lordosis. It is suggested that this method may replace those that are costly and involve health risks, such as radiography, in evaluating lumbar lordosis. PMID:22654681
Critical Values for Lawshe's Content Validity Ratio: Revisiting the Original Methods of Calculation
ERIC Educational Resources Information Center
Ayre, Colin; Scally, Andrew John
2014-01-01
The content validity ratio originally proposed by Lawshe is widely used to quantify content validity and yet methods used to calculate the original critical values were never reported. Methods for original calculation of critical values are suggested along with tables of exact binomial probabilities.
A long-term validation of the modernised DC-ARC-OES solid-sample method.
Flórián, K; Hassler, J; Förster, O
2001-12-01
The validation procedure based on ISO 17025 standard has been used to study and illustrate both the longterm stability of the calibration process of the DC-ARC solid sample spectrometric method and the main validation criteria of the method. In the calculation of the validation characteristics depending on the linearity(calibration), also the fulfilment of predetermining criteria such as normality and homoscedasticity was checked. In order to decide whether there are any trends in the time-variation of the analytical signal or not, also the Neumann test of trend was applied and evaluated. Finally, a comparison with similar validation data of the ETV-ICP-OES method was carried out.
VALUE - A Framework to Validate Downscaling Approaches for Climate Change Studies
NASA Astrophysics Data System (ADS)
Maraun, Douglas; Widmann, Martin; Gutiérrez, José M.; Kotlarski, Sven; Chandler, Richard E.; Hertig, Elke; Wibig, Joanna; Huth, Radan; Wilke, Renate A. I.
2015-04-01
VALUE is an open European network to validate and compare downscaling methods for climate change research. VALUE aims to foster collaboration and knowledge exchange between climatologists, impact modellers, statisticians, and stakeholders to establish an interdisciplinary downscaling community. A key deliverable of VALUE is the development of a systematic validation framework to enable the assessment and comparison of both dynamical and statistical downscaling methods. Here, we present the key ingredients of this framework. VALUE's main approach to validation is user-focused: starting from a specific user problem, a validation tree guides the selection of relevant validation indices and performance measures. Several experiments have been designed to isolate specific points in the downscaling procedure where problems may occur: what is the isolated downscaling skill? How do statistical and dynamical methods compare? How do methods perform at different spatial scales? Do methods fail in representing regional climate change? How is the overall representation of regional climate, including errors inherited from global climate models? The framework will be the basis for a comprehensive community-open downscaling intercomparison study, but is intended also to provide general guidance for other validation studies.
VALUE: A framework to validate downscaling approaches for climate change studies
NASA Astrophysics Data System (ADS)
Maraun, Douglas; Widmann, Martin; Gutiérrez, José M.; Kotlarski, Sven; Chandler, Richard E.; Hertig, Elke; Wibig, Joanna; Huth, Radan; Wilcke, Renate A. I.
2015-01-01
VALUE is an open European network to validate and compare downscaling methods for climate change research. VALUE aims to foster collaboration and knowledge exchange between climatologists, impact modellers, statisticians, and stakeholders to establish an interdisciplinary downscaling community. A key deliverable of VALUE is the development of a systematic validation framework to enable the assessment and comparison of both dynamical and statistical downscaling methods. In this paper, we present the key ingredients of this framework. VALUE's main approach to validation is user- focused: starting from a specific user problem, a validation tree guides the selection of relevant validation indices and performance measures. Several experiments have been designed to isolate specific points in the downscaling procedure where problems may occur: what is the isolated downscaling skill? How do statistical and dynamical methods compare? How do methods perform at different spatial scales? Do methods fail in representing regional climate change? How is the overall representation of regional climate, including errors inherited from global climate models? The framework will be the basis for a comprehensive community-open downscaling intercomparison study, but is intended also to provide general guidance for other validation studies.
VDA, a Method of Choosing a Better Algorithm with Fewer Validations
Kluger, Yuval
2011-01-01
The multitude of bioinformatics algorithms designed for performing a particular computational task presents end-users with the problem of selecting the most appropriate computational tool for analyzing their biological data. The choice of the best available method is often based on expensive experimental validation of the results. We propose an approach to design validation sets for method comparison and performance assessment that are effective in terms of cost and discrimination power. Validation Discriminant Analysis (VDA) is a method for designing a minimal validation dataset to allow reliable comparisons between the performances of different algorithms. Implementation of our VDA approach achieves this reduction by selecting predictions that maximize the minimum Hamming distance between algorithmic predictions in the validation set. We show that VDA can be used to correctly rank algorithms according to their performances. These results are further supported by simulations and by realistic algorithmic comparisons in silico. VDA is a novel, cost-efficient method for minimizing the number of validation experiments necessary for reliable performance estimation and fair comparison between algorithms. Our VDA software is available at http://sourceforge.net/projects/klugerlab/files/VDA/ PMID:22046256
Performance Ratings: Designs for Evaluating Their Validity and Accuracy.
1986-07-01
ratees with substantial validity and with little bias due to the ethod for rating. Convergent validity and discriminant validity account for approximately...The expanded research design suggests that purpose for the ratings has little influence on the multitrait-multimethod properties of the ratings...Convergent and discriminant validity again account for substantial differences in the ratings of performance. Little method bias is present; both methods of
Barrett, Eva; McCreesh, Karen; Lewis, Jeremy
2014-02-01
A wide array of instruments are available for non-invasive thoracic kyphosis measurement. Guidelines for selecting outcome measures for use in clinical and research practice recommend that properties such as validity and reliability are considered. This systematic review reports on the reliability and validity of non-invasive methods for measuring thoracic kyphosis. A systematic search of 11 electronic databases located studies assessing reliability and/or validity of non-invasive thoracic kyphosis measurement techniques. Two independent reviewers used a critical appraisal tool to assess the quality of retrieved studies. Data was extracted by the primary reviewer. The results were synthesized qualitatively using a level of evidence approach. 27 studies satisfied the eligibility criteria and were included in the review. The reliability, validity and both reliability and validity were investigated by sixteen, two and nine studies respectively. 17/27 studies were deemed to be of high quality. In total, 15 methods of thoracic kyphosis were evaluated in retrieved studies. All investigated methods showed high (ICC ≥ .7) to very high (ICC ≥ .9) levels of reliability. The validity of the methods ranged from low to very high. The strongest levels of evidence for reliability exists in support of the Debrunner kyphometer, Spinal Mouse and Flexicurve index, and for validity supports the arcometer and Flexicurve index. Further reliability and validity studies are required to strengthen the level of evidence for the remaining methods of measurement. This should be addressed by future research. Copyright © 2013 Elsevier Ltd. All rights reserved.
VALIDATION OF A METHOD FOR ESTIMATING LONG-TERM EXPOSURES BASED ON SHORT-TERM MEASUREMENTS
A method for estimating long-term exposures from short-term measurements is validated using data from a recent EPA study of exposure to fine particles. The method was developed a decade ago but data to validate it did not exist until recently. In this paper, data from repeated ...
VALIDATION OF A METHOD FOR ESTIMATING LONG-TERM EXPOSURES BASED ON SHORT-TERM MEASUREMENTS
A method for estimating long-term exposures from short-term measurements is validated using data from a recent EPA study of exposure to fine particles. The method was developed a decade ago but long-term exposure data to validate it did not exist until recently. In this paper, ...
Discriminant Validity Assessment: Use of Fornell & Larcker criterion versus HTMT Criterion
NASA Astrophysics Data System (ADS)
Hamid, M. R. Ab; Sami, W.; Mohmad Sidek, M. H.
2017-09-01
Assessment of discriminant validity is a must in any research that involves latent variables for the prevention of multicollinearity issues. Fornell and Larcker criterion is the most widely used method for this purpose. However, a new method has emerged for establishing the discriminant validity assessment through heterotrait-monotrait (HTMT) ratio of correlations method. Therefore, this article presents the results of discriminant validity assessment using these methods. Data from previous study was used that involved 429 respondents for empirical validation of value-based excellence model in higher education institutions (HEI) in Malaysia. From the analysis, the convergent, divergent and discriminant validity were established and admissible using Fornell and Larcker criterion. However, the discriminant validity is an issue when employing the HTMT criterion. This shows that the latent variables under study faced the issue of multicollinearity and should be looked into for further details. This also implied that the HTMT criterion is a stringent measure that could detect the possible indiscriminant among the latent variables. In conclusion, the instrument which consisted of six latent variables was still lacking in terms of discriminant validity and should be explored further.
Reliability and validity of the AutoCAD software method in lumbar lordosis measurement.
Letafatkar, Amir; Amirsasan, Ramin; Abdolvahabi, Zahra; Hadadnezhad, Malihe
2011-12-01
The aim of this study was to determine the reliability and validity of the AutoCAD software method in lumbar lordosis measurement. Fifty healthy volunteers with a mean age of 23 ± 1.80 years were enrolled. A lumbar lateral radiograph was taken on all participants, and the lordosis was measured according to the Cobb method. Afterward, the lumbar lordosis degree was measured via AutoCAD software and flexible ruler methods. The current study is accomplished in 2 parts: intratester and intertester evaluations of reliability as well as the validity of the flexible ruler and software methods. Based on the intraclass correlation coefficient, AutoCAD's reliability and validity in measuring lumbar lordosis were 0.984 and 0.962, respectively. AutoCAD showed to be a reliable and valid method to measure lordosis. It is suggested that this method may replace those that are costly and involve health risks, such as radiography, in evaluating lumbar lordosis.
Cross-Validation of Survival Bump Hunting by Recursive Peeling Methods.
Dazard, Jean-Eudes; Choe, Michael; LeBlanc, Michael; Rao, J Sunil
2014-08-01
We introduce a survival/risk bump hunting framework to build a bump hunting model with a possibly censored time-to-event type of response and to validate model estimates. First, we describe the use of adequate survival peeling criteria to build a survival/risk bump hunting model based on recursive peeling methods. Our method called "Patient Recursive Survival Peeling" is a rule-induction method that makes use of specific peeling criteria such as hazard ratio or log-rank statistics. Second, to validate our model estimates and improve survival prediction accuracy, we describe a resampling-based validation technique specifically designed for the joint task of decision rule making by recursive peeling (i.e. decision-box) and survival estimation. This alternative technique, called "combined" cross-validation is done by combining test samples over the cross-validation loops, a design allowing for bump hunting by recursive peeling in a survival setting. We provide empirical results showing the importance of cross-validation and replication.
Cross-Validation of Survival Bump Hunting by Recursive Peeling Methods
Dazard, Jean-Eudes; Choe, Michael; LeBlanc, Michael; Rao, J. Sunil
2015-01-01
We introduce a survival/risk bump hunting framework to build a bump hunting model with a possibly censored time-to-event type of response and to validate model estimates. First, we describe the use of adequate survival peeling criteria to build a survival/risk bump hunting model based on recursive peeling methods. Our method called “Patient Recursive Survival Peeling” is a rule-induction method that makes use of specific peeling criteria such as hazard ratio or log-rank statistics. Second, to validate our model estimates and improve survival prediction accuracy, we describe a resampling-based validation technique specifically designed for the joint task of decision rule making by recursive peeling (i.e. decision-box) and survival estimation. This alternative technique, called “combined” cross-validation is done by combining test samples over the cross-validation loops, a design allowing for bump hunting by recursive peeling in a survival setting. We provide empirical results showing the importance of cross-validation and replication. PMID:26997922
Validation Methods for Fault-Tolerant avionics and control systems, working group meeting 1
NASA Technical Reports Server (NTRS)
1979-01-01
The proceedings of the first working group meeting on validation methods for fault tolerant computer design are presented. The state of the art in fault tolerant computer validation was examined in order to provide a framework for future discussions concerning research issues for the validation of fault tolerant avionics and flight control systems. The development of positions concerning critical aspects of the validation process are given.
External validation of a Cox prognostic model: principles and methods
2013-01-01
Background A prognostic model should not enter clinical practice unless it has been demonstrated that it performs a useful role. External validation denotes evaluation of model performance in a sample independent of that used to develop the model. Unlike for logistic regression models, external validation of Cox models is sparsely treated in the literature. Successful validation of a model means achieving satisfactory discrimination and calibration (prediction accuracy) in the validation sample. Validating Cox models is not straightforward because event probabilities are estimated relative to an unspecified baseline function. Methods We describe statistical approaches to external validation of a published Cox model according to the level of published information, specifically (1) the prognostic index only, (2) the prognostic index together with Kaplan-Meier curves for risk groups, and (3) the first two plus the baseline survival curve (the estimated survival function at the mean prognostic index across the sample). The most challenging task, requiring level 3 information, is assessing calibration, for which we suggest a method of approximating the baseline survival function. Results We apply the methods to two comparable datasets in primary breast cancer, treating one as derivation and the other as validation sample. Results are presented for discrimination and calibration. We demonstrate plots of survival probabilities that can assist model evaluation. Conclusions Our validation methods are applicable to a wide range of prognostic studies and provide researchers with a toolkit for external validation of a published Cox model. PMID:23496923
Nelson, Jennifer C.; Marsh, Tracey; Lumley, Thomas; Larson, Eric B.; Jackson, Lisa A.; Jackson, Michael
2014-01-01
Objective Estimates of treatment effectiveness in epidemiologic studies using large observational health care databases may be biased due to inaccurate or incomplete information on important confounders. Study methods that collect and incorporate more comprehensive confounder data on a validation cohort may reduce confounding bias. Study Design and Setting We applied two such methods, imputation and reweighting, to Group Health administrative data (full sample) supplemented by more detailed confounder data from the Adult Changes in Thought study (validation sample). We used influenza vaccination effectiveness (with an unexposed comparator group) as an example and evaluated each method’s ability to reduce bias using the control time period prior to influenza circulation. Results Both methods reduced, but did not completely eliminate, the bias compared with traditional effectiveness estimates that do not utilize the validation sample confounders. Conclusion Although these results support the use of validation sampling methods to improve the accuracy of comparative effectiveness findings from healthcare database studies, they also illustrate that the success of such methods depends on many factors, including the ability to measure important confounders in a representative and large enough validation sample, the comparability of the full sample and validation sample, and the accuracy with which data can be imputed or reweighted using the additional validation sample information. PMID:23849144
Survey of Verification and Validation Techniques for Small Satellite Software Development
NASA Technical Reports Server (NTRS)
Jacklin, Stephen A.
2015-01-01
The purpose of this paper is to provide an overview of the current trends and practices in small-satellite software verification and validation. This document is not intended to promote a specific software assurance method. Rather, it seeks to present an unbiased survey of software assurance methods used to verify and validate small satellite software and to make mention of the benefits and value of each approach. These methods include simulation and testing, verification and validation with model-based design, formal methods, and fault-tolerant software design with run-time monitoring. Although the literature reveals that simulation and testing has by far the longest legacy, model-based design methods are proving to be useful for software verification and validation. Some work in formal methods, though not widely used for any satellites, may offer new ways to improve small satellite software verification and validation. These methods need to be further advanced to deal with the state explosion problem and to make them more usable by small-satellite software engineers to be regularly applied to software verification. Last, it is explained how run-time monitoring, combined with fault-tolerant software design methods, provides an important means to detect and correct software errors that escape the verification process or those errors that are produced after launch through the effects of ionizing radiation.
Haddad, Monoem; Stylianides, Georgios; Djaoui, Leo; Dellal, Alexandre; Chamari, Karim
2017-01-01
Purpose: The aim of this review is to (1) retrieve all data validating the Session-rating of perceived exertion (RPE)-method using various criteria, (2) highlight the rationale of this method and its ecological usefulness, and (3) describe factors that can alter RPE and users of this method should take into consideration. Method: Search engines such as SPORTDiscus, PubMed, and Google Scholar databases in the English language between 2001 and 2016 were consulted for the validity and usefulness of the session-RPE method. Studies were considered for further analysis when they used the session-RPE method proposed by Foster et al. in 2001. Participants were athletes of any gender, age, or level of competition. Studies using languages other than English were excluded in the analysis of the validity and reliability of the session-RPE method. Other studies were examined to explain the rationale of the session-RPE method and the origin of RPE. Results: A total of 950 studies cited the Foster et al. study that proposed the session RPE-method. 36 studies have examined the validity and reliability of this proposed method using the modified CR-10. Conclusion: These studies confirmed the validity and good reliability and internal consistency of session-RPE method in several sports and physical activities with men and women of different age categories (children, adolescents, and adults) among various expertise levels. This method could be used as “standing alone” method for training load (TL) monitoring purposes though some recommend to combine it with other physiological parameters as heart rate. PMID:29163016
Miciak, Jeremy; Fletcher, Jack M.; Stuebing, Karla; Vaughn, Sharon; Tolar, Tammy D.
2014-01-01
Purpose Few empirical investigations have evaluated LD identification methods based on a pattern of cognitive strengths and weaknesses (PSW). This study investigated the reliability and validity of two proposed PSW methods: the concordance/discordance method (C/DM) and cross battery assessment (XBA) method. Methods Cognitive assessment data for 139 adolescents demonstrating inadequate response to intervention was utilized to empirically classify participants as meeting or not meeting PSW LD identification criteria using the two approaches, permitting an analysis of: (1) LD identification rates; (2) agreement between methods; and (3) external validity. Results LD identification rates varied between the two methods depending upon the cut point for low achievement, with low agreement for LD identification decisions. Comparisons of groups that met and did not meet LD identification criteria on external academic variables were largely null, raising questions of external validity. Conclusions This study found low agreement and little evidence of validity for LD identification decisions based on PSW methods. An alternative may be to use multiple measures of academic achievement to guide intervention. PMID:24274155
Hansen, Clint; Venture, Gentiane; Rezzoug, Nasser; Gorce, Philippe; Isableu, Brice
2014-05-07
Over the last decades a variety of research has been conducted with the goal to improve the Body Segment Inertial Parameters (BSIP) estimations but to our knowledge a real validation has never been completely successful, because no ground truth is available. The aim of this paper is to propose a validation method for a BSIP identification method (IM) and to confirm the results by comparing them with recalculated contact forces using inverse dynamics to those obtained by a force plate. Furthermore, the results are compared with the recently proposed estimation method by Dumas et al. (2007). Additionally, the results are cross validated with a high velocity overarm throwing movement. Throughout conditions higher correlations, smaller metrics and smaller RMSE can be found for the proposed BSIP estimation (IM) which shows its advantage compared to recently proposed methods as of Dumas et al. (2007). The purpose of the paper is to validate an already proposed method and to show that this method can be of significant advantage compared to conventional methods. Copyright © 2014 Elsevier Ltd. All rights reserved.
The Value of Qualitative Methods in Social Validity Research
ERIC Educational Resources Information Center
Leko, Melinda M.
2014-01-01
One quality indicator of intervention research is the extent to which the intervention has a high degree of social validity, or practicality. In this study, I drew on Wolf's framework for social validity and used qualitative methods to ascertain five middle schoolteachers' perceptions of the social validity of System 44®--a phonics-based reading…
ERIC Educational Resources Information Center
Daigneault, Pierre-Marc; Jacob, Steve
2014-01-01
Although combining methods is nothing new, more contributions about why and how to mix methods for validation purposes are needed. This article presents a case of validating the inferences drawn from the Participatory Evaluation Measurement Instrument, an instrument that purports to measure stakeholder participation in evaluation. Although the…
Pereira, Taísa Sabrina Silva; Cade, Nágela Valadão; Mill, José Geraldo; Sichieri, Rosely; Molina, Maria del Carmen Bisi
2016-01-01
Introduction Biomarkers are a good choice to be used in the validation of food frequency questionnaire due to the independence of their random errors. Objective To assess the validity of the potassium and sodium intake estimated using the Food Frequency Questionnaire ELSA-Brasil. Subjects/Methods A subsample of participants in the ELSA-Brasil cohort was included in this study in 2009. Sodium and potassium intake were estimated using three methods: Semi-quantitative food frequency questionnaire, 12-hour nocturnal urinary excretion and three 24-hour food records. Correlation coefficients were calculated between the methods, and the validity coefficient was calculated using the method of triads. The 95% confidence intervals for the validity coefficient were estimated using bootstrap sampling. Exact and adjacent agreement and disagreement of the estimated sodium and potassium intake quintiles were compared among three methods. Results The sample consisted of 246 participants, aged 53±8 years, 52% of women. Validity coefficient for sodium were considered weak (рfood frequency questionnaire actual intake = 0.37 and рbiomarker actual intake = 0.21) and moderate (рfood records actual intake 0.56). The validity coefficient were higher for potassium (рfood frequency questionnaire actual intake = 0.60; рbiomarker actual intake = 0.42; рfood records actual intake = 0.79). Conclusions: The Food Frequency Questionnaire ELSA-Brasil showed good validity in estimating potassium intake in epidemiological studies. For sodium validity was weak, likely due to the non-quantification of the added salt to prepared food. PMID:28030625
Increased efficacy for in-house validation of real-time PCR GMO detection methods.
Scholtens, I M J; Kok, E J; Hougs, L; Molenaar, B; Thissen, J T N M; van der Voet, H
2010-03-01
To improve the efficacy of the in-house validation of GMO detection methods (DNA isolation and real-time PCR, polymerase chain reaction), a study was performed to gain insight in the contribution of the different steps of the GMO detection method to the repeatability and in-house reproducibility. In the present study, 19 methods for (GM) soy, maize canola and potato were validated in-house of which 14 on the basis of an 8-day validation scheme using eight different samples and five on the basis of a more concise validation protocol. In this way, data was obtained with respect to the detection limit, accuracy and precision. Also, decision limits were calculated for declaring non-conformance (>0.9%) with 95% reliability. In order to estimate the contribution of the different steps in the GMO analysis to the total variation variance components were estimated using REML (residual maximum likelihood method). From these components, relative standard deviations for repeatability and reproducibility (RSD(r) and RSD(R)) were calculated. The results showed that not only the PCR reaction but also the factors 'DNA isolation' and 'PCR day' are important factors for the total variance and should therefore be included in the in-house validation. It is proposed to use a statistical model to estimate these factors from a large dataset of initial validations so that for similar GMO methods in the future, only the PCR step needs to be validated. The resulting data are discussed in the light of agreed European criteria for qualified GMO detection methods.
Validation of Milliflex® Quantum for Bioburden Testing of Pharmaceutical Products.
Gordon, Oliver; Goverde, Marcel; Staerk, Alexandra; Roesti, David
2017-01-01
This article reports the validation strategy used to demonstrate that the Milliflex ® Quantum yielded non-inferior results to the traditional bioburden method. It was validated according to USP <1223>, European Pharmacopoeia 5.1.6, and Parenteral Drug Association Technical Report No. 33 and comprised the validation parameters robustness, ruggedness, repeatability, specificity, limit of detection and quantification, accuracy, precision, linearity, range, and equivalence in routine operation. For the validation, a combination of pharmacopeial ATCC strains as well as a broad selection of in-house isolates were used. In-house isolates were used in stressed state. Results were statistically evaluated regarding the pharmacopeial acceptance criterion of ≥70% recovery compared to the traditional method. Post-hoc test power calculations verified the appropriateness of the used sample size to detect such a difference. Furthermore, equivalence tests verified non-inferiority of the rapid method as compared to the traditional method. In conclusion, the rapid bioburden on basis of the Milliflex ® Quantum was successfully validated as alternative method to the traditional bioburden test. LAY ABSTRACT: Pharmaceutical drug products must fulfill specified quality criteria regarding their microbial content in order to ensure patient safety. Drugs that are delivered into the body via injection, infusion, or implantation must be sterile (i.e., devoid of living microorganisms). Bioburden testing measures the levels of microbes present in the bulk solution of a drug before sterilization, and thus it provides important information for manufacturing a safe product. In general, bioburden testing has to be performed using the methods described in the pharmacopoeias (membrane filtration or plate count). These methods are well established and validated regarding their effectiveness; however, the incubation time required to visually identify microbial colonies is long. Thus, alternative methods that detect microbial contamination faster will improve control over the manufacturing process and speed up product release. Before alternative methods may be used, they must undergo a side-by-side comparison with pharmacopeial methods. In this comparison, referred to as validation, it must be shown in a statistically verified manner that the effectiveness of the alternative method is at least equivalent to that of the pharmacopeial methods. Here we describe the successful validation of an alternative bioburden testing method based on fluorescent staining of growing microorganisms applying the Milliflex ® Quantum system by MilliporeSigma. © PDA, Inc. 2017.
Rosing, H.; Hillebrand, M. J. X.; Blesson, S.; Mengesha, B.; Diro, E.; Hailu, A.; Schellens, J. H. M.; Beijnen, J. H.
2016-01-01
To facilitate future pharmacokinetic studies of combination treatments against leishmaniasis in remote regions in which the disease is endemic, a simple cheap sampling method is required for miltefosine quantification. The aims of this study were to validate a liquid chromatography-tandem mass spectrometry method to quantify miltefosine in dried blood spot (DBS) samples and to validate its use with Ethiopian patients with visceral leishmaniasis (VL). Since hematocrit (Ht) levels are typically severely decreased in VL patients, returning to normal during treatment, the method was evaluated over a range of clinically relevant Ht values. Miltefosine was extracted from DBS samples using a simple method of pretreatment with methanol, resulting in >97% recovery. The method was validated over a calibration range of 10 to 2,000 ng/ml, and accuracy and precision were within ±11.2% and ≤7.0% (≤19.1% at the lower limit of quantification), respectively. The method was accurate and precise for blood spot volumes between 10 and 30 μl and for Ht levels of 20 to 35%, although a linear effect of Ht levels on miltefosine quantification was observed in the bioanalytical validation. DBS samples were stable for at least 162 days at 37°C. Clinical validation of the method using paired DBS and plasma samples from 16 VL patients showed a median observed DBS/plasma miltefosine concentration ratio of 0.99, with good correlation (Pearson's r = 0.946). Correcting for patient-specific Ht levels did not further improve the concordance between the sampling methods. This successfully validated method to quantify miltefosine in DBS samples was demonstrated to be a valid and practical alternative to venous blood sampling that can be applied in future miltefosine pharmacokinetic studies with leishmaniasis patients, without Ht correction. PMID:26787691
Majumdar, Subhabrata; Basak, Subhash C
2018-04-26
Proper validation is an important aspect of QSAR modelling. External validation is one of the widely used validation methods in QSAR where the model is built on a subset of the data and validated on the rest of the samples. However, its effectiveness for datasets with a small number of samples but large number of predictors remains suspect. Calculating hundreds or thousands of molecular descriptors using currently available software has become the norm in QSAR research, owing to computational advances in the past few decades. Thus, for n chemical compounds and p descriptors calculated for each molecule, the typical chemometric dataset today has high value of p but small n (i.e. n < p). Motivated by the evidence of inadequacies of external validation in estimating the true predictive capability of a statistical model in recent literature, this paper performs an extensive and comparative study of this method with several other validation techniques. We compared four validation methods: leave-one-out, K-fold, external and multi-split validation, using statistical models built using the LASSO regression, which simultaneously performs variable selection and modelling. We used 300 simulated datasets and one real dataset of 95 congeneric amine mutagens for this evaluation. External validation metrics have high variation among different random splits of the data, hence are not recommended for predictive QSAR models. LOO has the overall best performance among all validation methods applied in our scenario. Results from external validation are too unstable for the datasets we analyzed. Based on our findings, we recommend using the LOO procedure for validating QSAR predictive models built on high-dimensional small-sample data. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
A Generalized Pivotal Quantity Approach to Analytical Method Validation Based on Total Error.
Yang, Harry; Zhang, Jianchun
2015-01-01
The primary purpose of method validation is to demonstrate that the method is fit for its intended use. Traditionally, an analytical method is deemed valid if its performance characteristics such as accuracy and precision are shown to meet prespecified acceptance criteria. However, these acceptance criteria are not directly related to the method's intended purpose, which is usually a gurantee that a high percentage of the test results of future samples will be close to their true values. Alternate "fit for purpose" acceptance criteria based on the concept of total error have been increasingly used. Such criteria allow for assessing method validity, taking into account the relationship between accuracy and precision. Although several statistical test methods have been proposed in literature to test the "fit for purpose" hypothesis, the majority of the methods are not designed to protect the risk of accepting unsuitable methods, thus having the potential to cause uncontrolled consumer's risk. In this paper, we propose a test method based on generalized pivotal quantity inference. Through simulation studies, the performance of the method is compared to five existing approaches. The results show that both the new method and the method based on β-content tolerance interval with a confidence level of 90%, hereafter referred to as the β-content (0.9) method, control Type I error and thus consumer's risk, while the other existing methods do not. It is further demonstrated that the generalized pivotal quantity method is less conservative than the β-content (0.9) method when the analytical methods are biased, whereas it is more conservative when the analytical methods are unbiased. Therefore, selection of either the generalized pivotal quantity or β-content (0.9) method for an analytical method validation depends on the accuracy of the analytical method. It is also shown that the generalized pivotal quantity method has better asymptotic properties than all of the current methods. Analytical methods are often used to ensure safety, efficacy, and quality of medicinal products. According to government regulations and regulatory guidelines, these methods need to be validated through well-designed studies to minimize the risk of accepting unsuitable methods. This article describes a novel statistical test for analytical method validation, which provides better protection for the risk of accepting unsuitable analytical methods. © PDA, Inc. 2015.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ekechukwu, A
Method validation is the process of evaluating whether an analytical method is acceptable for its intended purpose. For pharmaceutical methods, guidelines from the United States Pharmacopeia (USP), International Conference on Harmonisation (ICH), and the United States Food and Drug Administration (USFDA) provide a framework for performing such valications. In general, methods for regulatory compliance must include studies on specificity, linearity, accuracy, precision, range, detection limit, quantitation limit, and robustness. Elements of these guidelines are readily adapted to the issue of validation for beryllium sampling and analysis. This document provides a listing of available sources which can be used to validatemore » analytical methods and/or instrumentation for beryllium determination. A literature review was conducted of available standard methods and publications used for method validation and/or quality control. A comprehensive listing of the articles, papers and books reviewed is given in the Appendix. Available validation documents and guides are listed therein; each has a brief description of application and use. In the referenced sources, there are varying approches to validation and varying descriptions of the valication process at different stages in method development. This discussion focuses on valication and verification of fully developed methods and instrumentation that have been offered up for use or approval by other laboratories or official consensus bodies such as ASTM International, the International Standards Organization (ISO) and the Association of Official Analytical Chemists (AOAC). This review was conducted as part of a collaborative effort to investigate and improve the state of validation for measuring beryllium in the workplace and the environment. Documents and publications from the United States and Europe are included. Unless otherwise specified, all referenced documents were published in English.« less
Do placebo based validation standards mimic real batch products behaviour? Case studies.
Bouabidi, A; Talbi, M; Bouklouze, A; El Karbane, M; Bourichi, H; El Guezzar, M; Ziemons, E; Hubert, Ph; Rozet, E
2011-06-01
Analytical methods validation is a mandatory step to evaluate the ability of developed methods to provide accurate results for their routine application. Validation usually involves validation standards or quality control samples that are prepared in placebo or reconstituted matrix made of a mixture of all the ingredients composing the drug product except the active substance or the analyte under investigation. However, one of the main concerns that can be made with this approach is that it may lack an important source of variability that come from the manufacturing process. The question that remains at the end of the validation step is about the transferability of the quantitative performance from validation standards to real authentic drug product samples. In this work, this topic is investigated through three case studies. Three analytical methods were validated using the commonly spiked placebo validation standards at several concentration levels as well as using samples coming from authentic batch samples (tablets and syrups). The results showed that, depending on the type of response function used as calibration curve, there were various degrees of differences in the results accuracy obtained with the two types of samples. Nonetheless the use of spiked placebo validation standards was showed to mimic relatively well the quantitative behaviour of the analytical methods with authentic batch samples. Adding these authentic batch samples into the validation design may help the analyst to select and confirm the most fit for purpose calibration curve and thus increase the accuracy and reliability of the results generated by the method in routine application. Copyright © 2011 Elsevier B.V. All rights reserved.
Method development and validation of potent pyrimidine derivative by UV-VIS spectrophotometer.
Chaudhary, Anshu; Singh, Anoop; Verma, Prabhakar Kumar
2014-12-01
A rapid and sensitive ultraviolet-visible (UV-VIS) spectroscopic method was developed for the estimation of pyrimidine derivative 6-Bromo-3-(6-(2,6-dichlorophenyl)-2-(morpolinomethylamino) pyrimidine4-yl) -2H-chromen-2-one (BT10M) in bulk form. Pyrimidine derivative was monitored at 275 nm with UV detection, and there is no interference of diluents at 275 nm. The method was found to be linear in the range of 50 to 150 μg/ml. The accuracy and precision were determined and validated statistically. The method was validated as a guideline. The results showed that the proposed method is suitable for the accurate, precise, and rapid determination of pyrimidine derivative. Graphical Abstract Method development and validation of potent pyrimidine derivative by UV spectroscopy.
Initial Validation of Ballistic Shock Transducers
2017-06-05
objective of this TOP is to describe various methods and instrumentation used in the initial validation of accelerometers to be used in both Ballistic...MILITARY STANDARD 810G CHANGE NOTICE 1, METHOD 522.2, SECTION 4.4.2 ....................................... A-1 B. GLOSSARY...Procedure (TOP) is to describe various methods and instrumentation used in the initial validation of accelerometers to be used in both Ballistic
Experimental validation of structural optimization methods
NASA Technical Reports Server (NTRS)
Adelman, Howard M.
1992-01-01
The topic of validating structural optimization methods by use of experimental results is addressed. The need for validating the methods as a way of effecting a greater and an accelerated acceptance of formal optimization methods by practicing engineering designers is described. The range of validation strategies is defined which includes comparison of optimization results with more traditional design approaches, establishing the accuracy of analyses used, and finally experimental validation of the optimization results. Examples of the use of experimental results to validate optimization techniques are described. The examples include experimental validation of the following: optimum design of a trussed beam; combined control-structure design of a cable-supported beam simulating an actively controlled space structure; minimum weight design of a beam with frequency constraints; minimization of the vibration response of helicopter rotor blade; minimum weight design of a turbine blade disk; aeroelastic optimization of an aircraft vertical fin; airfoil shape optimization for drag minimization; optimization of the shape of a hole in a plate for stress minimization; optimization to minimize beam dynamic response; and structural optimization of a low vibration helicopter rotor.
English, Sangeeta B.; Shih, Shou-Ching; Ramoni, Marco F.; Smith, Lois E.; Butte, Atul J.
2014-01-01
Though genome-wide technologies, such as microarrays, are widely used, data from these methods are considered noisy; there is still varied success in downstream biological validation. We report a method that increases the likelihood of successfully validating microarray findings using real time RT-PCR, including genes at low expression levels and with small differences. We use a Bayesian network to identify the most relevant sources of noise based on the successes and failures in validation for an initial set of selected genes, and then improve our subsequent selection of genes for validation based on eliminating these sources of noise. The network displays the significant sources of noise in an experiment, and scores the likelihood of validation for every gene. We show how the method can significantly increase validation success rates. In conclusion, in this study, we have successfully added a new automated step to determine the contributory sources of noise that determine successful or unsuccessful downstream biological validation. PMID:18790084
Deconinck, E; Crevits, S; Baten, P; Courselle, P; De Beer, J
2011-04-05
A fully validated UHPLC method for the identification and quantification of folic acid in pharmaceutical preparations was developed. The starting conditions for the development were calculated starting from the HPLC conditions of a validated method. These start conditions were tested on four different UHPLC columns: Grace Vision HT™ C18-P, C18, C18-HL and C18-B (2 mm × 100 mm, 1.5 μm). After selection of the stationary phase, the method was further optimised by testing two aqueous and two organic phases and by adapting to a gradient method. The obtained method was fully validated based on its measurement uncertainty (accuracy profile) and robustness tests. A UHPLC method was obtained for the identification and quantification of folic acid in pharmaceutical preparations, which will cut analysis times and solvent consumption. Copyright © 2010 Elsevier B.V. All rights reserved.
Probability of Detection (POD) as a statistical model for the validation of qualitative methods.
Wehling, Paul; LaBudde, Robert A; Brunelle, Sharon L; Nelson, Maria T
2011-01-01
A statistical model is presented for use in validation of qualitative methods. This model, termed Probability of Detection (POD), harmonizes the statistical concepts and parameters between quantitative and qualitative method validation. POD characterizes method response with respect to concentration as a continuous variable. The POD model provides a tool for graphical representation of response curves for qualitative methods. In addition, the model allows comparisons between candidate and reference methods, and provides calculations of repeatability, reproducibility, and laboratory effects from collaborative study data. Single laboratory study and collaborative study examples are given.
1985-03-01
conceptual framwork , and preliminary validation of IAT concepts. Planned work for FY85, including more extensive validation, is also described. 20...Developments: Required Capabilities .... ......... 10 2-1 IAT Conceptual Framework - FY85 (FEO) ..... ........... 11 2-2 Recursive Nature of Decomposition...approach: 1) Identify needs & requirements for IAT. 2) Develop IAT conceptual framework. 3) Validate IAT methods. 4) Develop applications materials. To
Methods to compute reliabilities for genomic predictions of feed intake
USDA-ARS?s Scientific Manuscript database
For new traits without historical reference data, cross-validation is often the preferred method to validate reliability (REL). Time truncation is less useful because few animals gain substantial REL after the truncation point. Accurate cross-validation requires separating genomic gain from pedigree...
Orsi, Rebecca
2017-02-01
Concept mapping is now a commonly-used technique for articulating and evaluating programmatic outcomes. However, research regarding validity of knowledge and outcomes produced with concept mapping is sparse. The current study describes quantitative validity analyses using a concept mapping dataset. We sought to increase the validity of concept mapping evaluation results by running multiple cluster analysis methods and then using several metrics to choose from among solutions. We present four different clustering methods based on analyses using the R statistical software package: partitioning around medoids (PAM), fuzzy analysis (FANNY), agglomerative nesting (AGNES) and divisive analysis (DIANA). We then used the Dunn and Davies-Bouldin indices to assist in choosing a valid cluster solution for a concept mapping outcomes evaluation. We conclude that the validity of the outcomes map is high, based on the analyses described. Finally, we discuss areas for further concept mapping methods research. Copyright © 2016 Elsevier Ltd. All rights reserved.
The NIH analytical methods and reference materials program for dietary supplements.
Betz, Joseph M; Fisher, Kenneth D; Saldanha, Leila G; Coates, Paul M
2007-09-01
Quality of botanical products is a great uncertainty that consumers, clinicians, regulators, and researchers face. Definitions of quality abound, and include specifications for sanitation, adventitious agents (pesticides, metals, weeds), and content of natural chemicals. Because dietary supplements (DS) are often complex mixtures, they pose analytical challenges and method validation may be difficult. In response to product quality concerns and the need for validated and publicly available methods for DS analysis, the US Congress directed the Office of Dietary Supplements (ODS) at the National Institutes of Health (NIH) to accelerate an ongoing methods validation process, and the Dietary Supplements Methods and Reference Materials Program was created. The program was constructed from stakeholder input and incorporates several federal procurement and granting mechanisms in a coordinated and interlocking framework. The framework facilitates validation of analytical methods, analytical standards, and reference materials.
Nonclinical dose formulation analysis method validation and sample analysis.
Whitmire, Monica Lee; Bryan, Peter; Henry, Teresa R; Holbrook, John; Lehmann, Paul; Mollitor, Thomas; Ohorodnik, Susan; Reed, David; Wietgrefe, Holly D
2010-12-01
Nonclinical dose formulation analysis methods are used to confirm test article concentration and homogeneity in formulations and determine formulation stability in support of regulated nonclinical studies. There is currently no regulatory guidance for nonclinical dose formulation analysis method validation or sample analysis. Regulatory guidance for the validation of analytical procedures has been developed for drug product/formulation testing; however, verification of the formulation concentrations falls under the framework of GLP regulations (not GMP). The only current related regulatory guidance is the bioanalytical guidance for method validation. The fundamental parameters for bioanalysis and formulation analysis validations that overlap include: recovery, accuracy, precision, specificity, selectivity, carryover, sensitivity, and stability. Divergence in bioanalytical and drug product validations typically center around the acceptance criteria used. As the dose formulation samples are not true "unknowns", the concept of quality control samples that cover the entire range of the standard curve serving as the indication for the confidence in the data generated from the "unknown" study samples may not always be necessary. Also, the standard bioanalytical acceptance criteria may not be directly applicable, especially when the determined concentration does not match the target concentration. This paper attempts to reconcile the different practices being performed in the community and to provide recommendations of best practices and proposed acceptance criteria for nonclinical dose formulation method validation and sample analysis.
Prediction of adult height in girls: the Beunen-Malina-Freitas method.
Beunen, Gaston P; Malina, Robert M; Freitas, Duarte L; Thomis, Martine A; Maia, José A; Claessens, Albrecht L; Gouveia, Elvio R; Maes, Hermine H; Lefevre, Johan
2011-12-01
The purpose of this study was to validate and cross-validate the Beunen-Malina-Freitas method for non-invasive prediction of adult height in girls. A sample of 420 girls aged 10-15 years from the Madeira Growth Study were measured at yearly intervals and then 8 years later. Anthropometric dimensions (lengths, breadths, circumferences, and skinfolds) were measured; skeletal age was assessed using the Tanner-Whitehouse 3 method and menarcheal status (present or absent) was recorded. Adult height was measured and predicted using stepwise, forward, and maximum R (2) regression techniques. Multiple correlations, mean differences, standard errors of prediction, and error boundaries were calculated. A sample of the Leuven Longitudinal Twin Study was used to cross-validate the regressions. Age-specific coefficients of determination (R (2)) between predicted and measured adult height varied between 0.57 and 0.96, while standard errors of prediction varied between 1.1 and 3.9 cm. The cross-validation confirmed the validity of the Beunen-Malina-Freitas method in girls aged 12-15 years, but at lower ages the cross-validation was less consistent. We conclude that the Beunen-Malina-Freitas method is valid for the prediction of adult height in girls aged 12-15 years. It is applicable to European populations or populations of European ancestry.
Evaluation of coarse scale land surface remote sensing albedo product over rugged terrain
NASA Astrophysics Data System (ADS)
Wen, J.; Xinwen, L.; You, D.; Dou, B.
2017-12-01
Satellite derived Land surface albedo is an essential climate variable which controls the earth energy budget and it can be used in applications such as climate change, hydrology, and numerical weather prediction. The accuracy and uncertainty of surface albedo products should be evaluated with a reliable reference truth data prior to applications. And more literatures investigated the validation methods about the albedo validation in a flat or homogenous surface. However, the albedo performance over rugged terrain is still unknow due to the validation method limited. A multi-validation strategy is implemented to give a comprehensive albedo validation, which will involve the high resolution albedo processing, high resolution albedo validation based on in situ albedo, and the method to upscale the high resolution albedo to a coarse scale albedo. Among them, the high resolution albedo generation and the upscale method is the core step for the coarse scale albedo validation. In this paper, the high resolution albedo is generated by Angular Bin algorithm. And a albedo upscale method over rugged terrain is developed to obtain the coarse scale albedo truth. The in situ albedo located 40 sites in mountain area are selected globally to validate the high resolution albedo, and then upscaled to the coarse scale albedo by the upscale method. This paper takes MODIS and GLASS albedo product as a example, and the prelimarily results show the RMSE of MODIS and GLASS albedo product over rugged terrain are 0.047 and 0.057, respectively under the RMSE with 0.036 of high resolution albedo.
Dynamic Time Warping compared to established methods for validation of musculoskeletal models.
Gaspar, Martin; Welke, Bastian; Seehaus, Frank; Hurschler, Christof; Schwarze, Michael
2017-04-11
By means of Multi-Body musculoskeletal simulation, important variables such as internal joint forces and moments can be estimated which cannot be measured directly. Validation can ensued by qualitative or by quantitative methods. Especially when comparing time-dependent signals, many methods do not perform well and validation is often limited to qualitative approaches. The aim of the present study was to investigate the capabilities of the Dynamic Time Warping (DTW) algorithm for comparing time series, which can quantify phase as well as amplitude errors. We contrast the sensitivity of DTW with other established metrics: the Pearson correlation coefficient, cross-correlation, the metric according to Geers, RMSE and normalized RMSE. This study is based on two data sets, where one data set represents direct validation and the other represents indirect validation. Direct validation was performed in the context of clinical gait-analysis on trans-femoral amputees fitted with a 6 component force-moment sensor. Measured forces and moments from amputees' socket-prosthesis are compared to simulated forces and moments. Indirect validation was performed in the context of surface EMG measurements on a cohort of healthy subjects with measurements taken of seven muscles of the leg, which were compared to simulated muscle activations. Regarding direct validation, a positive linear relation between results of RMSE and nRMSE to DTW can be seen. For indirect validation, a negative linear relation exists between Pearson correlation and cross-correlation. We propose the DTW algorithm for use in both direct and indirect quantitative validation as it correlates well with methods that are most suitable for one of the tasks. However, in DV it should be used together with methods resulting in a dimensional error value, in order to be able to interpret results more comprehensible. Copyright © 2017 Elsevier Ltd. All rights reserved.
Validation of a pulsed electric field process to pasteurize strawberry puree
USDA-ARS?s Scientific Manuscript database
An inexpensive data acquisition method was developed to validate the exact number and shape of the pulses applied during pulsed electric fields (PEF) processing. The novel validation method was evaluated in conjunction with developing a pasteurization PEF process for strawberry puree. Both buffered...
Pereira, Taísa Sabrina Silva; Cade, Nágela Valadão; Mill, José Geraldo; Sichieri, Rosely; Molina, Maria Del Carmen Bisi
2016-01-01
Biomarkers are a good choice to be used in the validation of food frequency questionnaire due to the independence of their random errors. To assess the validity of the potassium and sodium intake estimated using the Food Frequency Questionnaire ELSA-Brasil. A subsample of participants in the ELSA-Brasil cohort was included in this study in 2009. Sodium and potassium intake were estimated using three methods: Semi-quantitative food frequency questionnaire, 12-hour nocturnal urinary excretion and three 24-hour food records. Correlation coefficients were calculated between the methods, and the validity coefficient was calculated using the method of triads. The 95% confidence intervals for the validity coefficient were estimated using bootstrap sampling. Exact and adjacent agreement and disagreement of the estimated sodium and potassium intake quintiles were compared among three methods. The sample consisted of 246 participants, aged 53±8 years, 52% of women. Validity coefficient for sodium were considered weak (рfood frequency questionnaire actual intake = 0.37 and рbiomarker actual intake = 0.21) and moderate (рfood records actual intake 0.56). The validity coefficient were higher for potassium (рfood frequency questionnaire actual intake = 0.60; рbiomarker actual intake = 0.42; рfood records actual intake = 0.79). Conclusions: The Food Frequency Questionnaire ELSA-Brasil showed good validity in estimating potassium intake in epidemiological studies. For sodium validity was weak, likely due to the non-quantification of the added salt to prepared food.
International Harmonization and Cooperation in the Validation of Alternative Methods.
Barroso, João; Ahn, Il Young; Caldeira, Cristiane; Carmichael, Paul L; Casey, Warren; Coecke, Sandra; Curren, Rodger; Desprez, Bertrand; Eskes, Chantra; Griesinger, Claudius; Guo, Jiabin; Hill, Erin; Roi, Annett Janusch; Kojima, Hajime; Li, Jin; Lim, Chae Hyung; Moura, Wlamir; Nishikawa, Akiyoshi; Park, HyeKyung; Peng, Shuangqing; Presgrave, Octavio; Singer, Tim; Sohn, Soo Jung; Westmoreland, Carl; Whelan, Maurice; Yang, Xingfen; Yang, Ying; Zuang, Valérie
The development and validation of scientific alternatives to animal testing is important not only from an ethical perspective (implementation of 3Rs), but also to improve safety assessment decision making with the use of mechanistic information of higher relevance to humans. To be effective in these efforts, it is however imperative that validation centres, industry, regulatory bodies, academia and other interested parties ensure a strong international cooperation, cross-sector collaboration and intense communication in the design, execution, and peer review of validation studies. Such an approach is critical to achieve harmonized and more transparent approaches to method validation, peer-review and recommendation, which will ultimately expedite the international acceptance of valid alternative methods or strategies by regulatory authorities and their implementation and use by stakeholders. It also allows achieving greater efficiency and effectiveness by avoiding duplication of effort and leveraging limited resources. In view of achieving these goals, the International Cooperation on Alternative Test Methods (ICATM) was established in 2009 by validation centres from Europe, USA, Canada and Japan. ICATM was later joined by Korea in 2011 and currently also counts with Brazil and China as observers. This chapter describes the existing differences across world regions and major efforts carried out for achieving consistent international cooperation and harmonization in the validation and adoption of alternative approaches to animal testing.
Determination of Ethanol in Kombucha Products: Single-Laboratory Validation, First Action 2016.12.
Ebersole, Blake; Liu, Ying; Schmidt, Rich; Eckert, Matt; Brown, Paula N
2017-05-01
Kombucha is a fermented nonalcoholic beverage that has drawn government attention due to the possible presence of excess ethanol (≥0.5% alcohol by volume; ABV). A validated method that provides better precision and accuracy for measuring ethanol levels in kombucha is urgently needed by the kombucha industry. The current study validated a method for determining ethanol content in commercial kombucha products. The ethanol content in kombucha was measured using headspace GC with flame ionization detection. An ethanol standard curve ranging from 0.05 to 5.09% ABV was used, with correlation coefficients greater than 99.9%. The method detection limit was 0.003% ABV and the LOQ was 0.01% ABV. The RSDr ranged from 1.62 to 2.21% and the Horwitz ratio ranged from 0.4 to 0.6. The average accuracy of the method was 98.2%. This method was validated following the guidelines for single-laboratory validation by AOAC INTERNATIONAL and meets the requirements set by AOAC SMPR 2016.001, "Standard Method Performance Requirements for Determination of Ethanol in Kombucha."
USDA-ARS?s Scientific Manuscript database
Information to support application of hydrologic and water quality (H/WQ) models abounds, yet modelers commonly use arbitrary, ad hoc methods to conduct, document, and report model calibration, validation, and evaluation. Consistent methods are needed to improve model calibration, validation, and e...
ERIC Educational Resources Information Center
Luyt, Russell
2012-01-01
A framework for quantitative measurement development, validation, and revision that incorporates both qualitative and quantitative methods is introduced. It extends and adapts Adcock and Collier's work, and thus, facilitates understanding of quantitative measurement development, validation, and revision as an integrated and cyclical set of…
Evaluation of Criterion Validity for Scales with Congeneric Measures
ERIC Educational Resources Information Center
Raykov, Tenko
2007-01-01
A method for estimating criterion validity of scales with homogeneous components is outlined. It accomplishes point and interval estimation of interrelationship indices between composite scores and criterion variables and is useful for testing hypotheses about criterion validity of measurement instruments. The method can also be used with missing…
AZARI, Nadia; SOLEIMANI, Farin; VAMEGHI, Roshanak; SAJEDI, Firoozeh; SHAHSHAHANI, Soheila; KARIMI, Hossein; KRASKIAN, Adis; SHAHROKHI, Amin; TEYMOURI, Robab; GHARIB, Masoud
2017-01-01
Objective Bayley Scales of infant & toddler development is a well-known diagnostic developmental assessment tool for children aged 1–42 months. Our aim was investigating the validity & reliability of this scale in Persian speaking children. Materials & Methods The method was descriptive-analytic. Translation- back translation and cultural adaptation was done. Content & face validity of translated scale was determined by experts’ opinions. Overall, 403 children aged 1 to 42 months were recruited from health centers of Tehran, during years of 2013-2014 for developmental assessment in cognitive, communicative (receptive & expressive) and motor (fine & gross) domains. Reliability of scale was calculated through three methods; internal consistency using Cronbach’s alpha coefficient, test-retest and interrater methods. Construct validity was calculated using factor analysis and comparison of the mean scores methods. Results Cultural and linguistic changes were made in items of all domains especially on communication subscale. Content and face validity of the test were approved by experts’ opinions. Cronbach’s alpha coefficient was above 0.74 in all domains. Pearson correlation coefficient in various domains, were ≥ 0.982 in test retest method, and ≥0.993 in inter-rater method. Construct validity of the test was approved by factor analysis. Moreover, the mean scores for the different age groups were compared and statistically significant differences were observed between mean scores of different age groups, that confirms validity of the test. Conclusion The Bayley Scales of Infant and Toddler Development is a valid and reliable tool for child developmental assessment in Persian language children. PMID:28277556
Validity of three clinical performance assessments of internal medicine clerks.
Hull, A L; Hodder, S; Berger, B; Ginsberg, D; Lindheim, N; Quan, J; Kleinhenz, M E
1995-06-01
To analyze the construct validity of three methods to assess the clinical performances of internal medicine clerks. A multitrait-multimethod (MTMM) study was conducted at the Case Western Reserve University School of Medicine to determine the convergent and divergent validity of a clinical evaluation form (CEF) completed by faculty and residents, an objective structured clinical examination (OSCE), and the medicine subject test of the National Board of Medical Examiners. Three traits were involved in the analysis: clinical skills, knowledge, and personal characteristics. A correlation matrix was computed for 410 third-year students who completed the clerkship between August 1988 and July 1991. There was a significant (p < .01) convergence of the four correlations that assessed the same traits by using different methods. However, the four convergent correlations were of moderate magnitude (ranging from .29 to .47). Divergent validity was assessed by comparing the magnitudes of the convergence correlations with the magnitudes of correlations among unrelated assessments (i.e., different traits by different methods). Seven of nine possible coefficients were smaller than the convergent coefficients, suggesting evidence of divergent validity. A significant CEF method effect was identified. There was convergent validity and some evidence of divergent validity with a significant method effect. The findings were similar for correlations corrected for attenuation. Four conclusions were reached: (1) the reliability of the OSCE must be improved, (2) the CEF ratings must be redesigned to further discriminate among the specific traits assessed, (3) additional methods to assess personal characteristics must be instituted, and (4) several assessment methods should be used to evaluate individual student performances.
Empirical Performance of Cross-Validation With Oracle Methods in a Genomics Context.
Martinez, Josue G; Carroll, Raymond J; Müller, Samuel; Sampson, Joshua N; Chatterjee, Nilanjan
2011-11-01
When employing model selection methods with oracle properties such as the smoothly clipped absolute deviation (SCAD) and the Adaptive Lasso, it is typical to estimate the smoothing parameter by m-fold cross-validation, for example, m = 10. In problems where the true regression function is sparse and the signals large, such cross-validation typically works well. However, in regression modeling of genomic studies involving Single Nucleotide Polymorphisms (SNP), the true regression functions, while thought to be sparse, do not have large signals. We demonstrate empirically that in such problems, the number of selected variables using SCAD and the Adaptive Lasso, with 10-fold cross-validation, is a random variable that has considerable and surprising variation. Similar remarks apply to non-oracle methods such as the Lasso. Our study strongly questions the suitability of performing only a single run of m-fold cross-validation with any oracle method, and not just the SCAD and Adaptive Lasso.
Fault-tolerant clock synchronization validation methodology. [in computer systems
NASA Technical Reports Server (NTRS)
Butler, Ricky W.; Palumbo, Daniel L.; Johnson, Sally C.
1987-01-01
A validation method for the synchronization subsystem of a fault-tolerant computer system is presented. The high reliability requirement of flight-crucial systems precludes the use of most traditional validation methods. The method presented utilizes formal design proof to uncover design and coding errors and experimentation to validate the assumptions of the design proof. The experimental method is described and illustrated by validating the clock synchronization system of the Software Implemented Fault Tolerance computer. The design proof of the algorithm includes a theorem that defines the maximum skew between any two nonfaulty clocks in the system in terms of specific system parameters. Most of these parameters are deterministic. One crucial parameter is the upper bound on the clock read error, which is stochastic. The probability that this upper bound is exceeded is calculated from data obtained by the measurement of system parameters. This probability is then included in a detailed reliability analysis of the system.
Review of surface steam sterilization for validation purposes.
van Doornmalen, Joost; Kopinga, Klaas
2008-03-01
Sterilization is an essential step in the process of producing sterile medical devices. To guarantee sterility, the process of sterilization must be validated. Because there is no direct way to measure sterility, the techniques applied to validate the sterilization process are based on statistical principles. Steam sterilization is the most frequently applied sterilization method worldwide and can be validated either by indicators (chemical or biological) or physical measurements. The steam sterilization conditions are described in the literature. Starting from these conditions, criteria for the validation of steam sterilization are derived and can be described in terms of physical parameters. Physical validation of steam sterilization appears to be an adequate and efficient validation method that could be considered as an alternative for indicator validation. Moreover, physical validation can be used for effective troubleshooting in steam sterilizing processes.
Nse, Odunaiya; Quinette, Louw; Okechukwu, Ogah
2015-09-01
Well developed and validated lifestyle cardiovascular disease (CVD) risk factors questionnaires is the key to obtaining accurate information to enable planning of CVD prevention program which is a necessity in developing countries. We conducted this review to assess methods and processes used for development and content validation of lifestyle CVD risk factors questionnaires and possibly develop an evidence based guideline for development and content validation of lifestyle CVD risk factors questionnaires. Relevant databases at the Stellenbosch University library were searched for studies conducted between 2008 and 2012, in English language and among humans. Using the following databases; pubmed, cinahl, psyc info and proquest. Search terms used were CVD risk factors, questionnaires, smoking, alcohol, physical activity and diet. Methods identified for development of lifestyle CVD risk factors were; review of literature either systematic or traditional, involvement of expert and /or target population using focus group discussion/interview, clinical experience of authors and deductive reasoning of authors. For validation, methods used were; the involvement of expert panel, the use of target population and factor analysis. Combination of methods produces questionnaires with good content validity and other psychometric properties which we consider good.
Analysis of Ethanolamines: Validation of Semi-Volatile Analysis by HPLC-MS/MS by EPA Method MS888
DOE Office of Scientific and Technical Information (OSTI.GOV)
Owens, J; Vu, A; Koester, C
The Environmental Protection Agency's (EPA) Region 5 Chicago Regional Laboratory (CRL) developed a method titled 'Analysis of Diethanolamine, Triethanolamine, n-Methyldiethanolamine, and n-Ethyldiethanolamine in Water by Single Reaction Monitoring Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS): EPA Method MS888'. This draft standard operating procedure (SOP) was distributed to multiple EPA laboratories and to Lawrence Livermore National Laboratory, which was tasked to serve as a reference laboratory for EPA's Environmental Reference Laboratory Network (ERLN) and to develop and validate analytical procedures. The primary objective of this study was to validate and verify the analytical procedures described in 'EPA Method MS888' for analysis of themore » listed ethanolamines in aqueous samples. The gathered data from this validation study will be used to: (1) demonstrate analytical method performance; (2) generate quality control acceptance criteria; and (3) revise the SOP to provide a validated method that would be available for use during a homeland security event. The data contained in this report will be compiled, by EPA CRL, with data generated by other EPA Regional laboratories so that performance metrics of 'EPA Method MS888' can be determined.« less
Azari, Nadia; Soleimani, Farin; Vameghi, Roshanak; Sajedi, Firoozeh; Shahshahani, Soheila; Karimi, Hossein; Kraskian, Adis; Shahrokhi, Amin; Teymouri, Robab; Gharib, Masoud
2017-01-01
Bayley Scales of infant & toddler development is a well-known diagnostic developmental assessment tool for children aged 1-42 months. Our aim was investigating the validity & reliability of this scale in Persian speaking children. The method was descriptive-analytic. Translation- back translation and cultural adaptation was done. Content & face validity of translated scale was determined by experts' opinions. Overall, 403 children aged 1 to 42 months were recruited from health centers of Tehran, during years of 2013-2014 for developmental assessment in cognitive, communicative (receptive & expressive) and motor (fine & gross) domains. Reliability of scale was calculated through three methods; internal consistency using Cronbach's alpha coefficient, test-retest and interrater methods. Construct validity was calculated using factor analysis and comparison of the mean scores methods. Cultural and linguistic changes were made in items of all domains especially on communication subscale. Content and face validity of the test were approved by experts' opinions. Cronbach's alpha coefficient was above 0.74 in all domains. Pearson correlation coefficient in various domains, were ≥ 0.982 in test retest method, and ≥0.993 in inter-rater method. Construct validity of the test was approved by factor analysis. Moreover, the mean scores for the different age groups were compared and statistically significant differences were observed between mean scores of different age groups, that confirms validity of the test. The Bayley Scales of Infant and Toddler Development is a valid and reliable tool for child developmental assessment in Persian language children.
NASA Astrophysics Data System (ADS)
Dörr, Dominik; Joppich, Tobias; Schirmaier, Fabian; Mosthaf, Tobias; Kärger, Luise; Henning, Frank
2016-10-01
Thermoforming of continuously fiber reinforced thermoplastics (CFRTP) is ideally suited to thin walled and complex shaped products. By means of forming simulation, an initial validation of the producibility of a specific geometry, an optimization of the forming process and the prediction of fiber-reorientation due to forming is possible. Nevertheless, applied methods need to be validated. Therefor a method is presented, which enables the calculation of error measures for the mismatch between simulation results and experimental tests, based on measurements with a conventional coordinate measuring device. As a quantitative measure, describing the curvature is provided, the presented method is also suitable for numerical or experimental sensitivity studies on wrinkling behavior. The applied methods for forming simulation, implemented in Abaqus explicit, are presented and applied to a generic geometry. The same geometry is tested experimentally and simulation and test results are compared by the proposed validation method.
Johnston, Marie; Dixon, Diane; Hart, Jo; Glidewell, Liz; Schröder, Carin; Pollard, Beth
2014-05-01
In studies involving theoretical constructs, it is important that measures have good content validity and that there is not contamination of measures by content from other constructs. While reliability and construct validity are routinely reported, to date, there has not been a satisfactory, transparent, and systematic method of assessing and reporting content validity. In this paper, we describe a methodology of discriminant content validity (DCV) and illustrate its application in three studies. Discriminant content validity involves six steps: construct definition, item selection, judge identification, judgement format, single-sample test of content validity, and assessment of discriminant items. In three studies, these steps were applied to a measure of illness perceptions (IPQ-R) and control cognitions. The IPQ-R performed well with most items being purely related to their target construct, although timeline and consequences had small problems. By contrast, the study of control cognitions identified problems in measuring constructs independently. In the final study, direct estimation response formats for theory of planned behaviour constructs were found to have as good DCV as Likert format. The DCV method allowed quantitative assessment of each item and can therefore inform the content validity of the measures assessed. The methods can be applied to assess content validity before or after collecting data to select the appropriate items to measure theoretical constructs. Further, the data reported for each item in Appendix S1 can be used in item or measure selection. Statement of contribution What is already known on this subject? There are agreed methods of assessing and reporting construct validity of measures of theoretical constructs, but not their content validity. Content validity is rarely reported in a systematic and transparent manner. What does this study add? The paper proposes discriminant content validity (DCV), a systematic and transparent method of assessing and reporting whether items assess the intended theoretical construct and only that construct. In three studies, DCV was applied to measures of illness perceptions, control cognitions, and theory of planned behaviour response formats. Appendix S1 gives content validity indices for each item of each questionnaire investigated. Discriminant content validity is ideally applied while the measure is being developed, before using to measure the construct(s), but can also be applied after using a measure. © 2014 The British Psychological Society.
A brief measure of attitudes toward mixed methods research in psychology.
Roberts, Lynne D; Povee, Kate
2014-01-01
The adoption of mixed methods research in psychology has trailed behind other social science disciplines. Teaching psychology students, academics, and practitioners about mixed methodologies may increase the use of mixed methods within the discipline. However, tailoring and evaluating education and training in mixed methodologies requires an understanding of, and way of measuring, attitudes toward mixed methods research in psychology. To date, no such measure exists. In this article we present the development and initial validation of a new measure: Attitudes toward Mixed Methods Research in Psychology. A pool of 42 items developed from previous qualitative research on attitudes toward mixed methods research along with validation measures was administered via an online survey to a convenience sample of 274 psychology students, academics and psychologists. Principal axis factoring with varimax rotation on a subset of the sample produced a four-factor, 12-item solution. Confirmatory factor analysis on a separate subset of the sample indicated that a higher order four factor model provided the best fit to the data. The four factors; 'Limited Exposure,' '(in)Compatibility,' 'Validity,' and 'Tokenistic Qualitative Component'; each have acceptable internal reliability. Known groups validity analyses based on preferred research orientation and self-rated mixed methods research skills, and convergent and divergent validity analyses based on measures of attitudes toward psychology as a science and scientist and practitioner orientation, provide initial validation of the measure. This brief, internally reliable measure can be used in assessing attitudes toward mixed methods research in psychology, measuring change in attitudes as part of the evaluation of mixed methods education, and in larger research programs.
Verification and Validation Studies for the LAVA CFD Solver
NASA Technical Reports Server (NTRS)
Moini-Yekta, Shayan; Barad, Michael F; Sozer, Emre; Brehm, Christoph; Housman, Jeffrey A.; Kiris, Cetin C.
2013-01-01
The verification and validation of the Launch Ascent and Vehicle Aerodynamics (LAVA) computational fluid dynamics (CFD) solver is presented. A modern strategy for verification and validation is described incorporating verification tests, validation benchmarks, continuous integration and version control methods for automated testing in a collaborative development environment. The purpose of the approach is to integrate the verification and validation process into the development of the solver and improve productivity. This paper uses the Method of Manufactured Solutions (MMS) for the verification of 2D Euler equations, 3D Navier-Stokes equations as well as turbulence models. A method for systematic refinement of unstructured grids is also presented. Verification using inviscid vortex propagation and flow over a flat plate is highlighted. Simulation results using laminar and turbulent flow past a NACA 0012 airfoil and ONERA M6 wing are validated against experimental and numerical data.
NASA Astrophysics Data System (ADS)
Gutiérrez, Jose Manuel; Maraun, Douglas; Widmann, Martin; Huth, Radan; Hertig, Elke; Benestad, Rasmus; Roessler, Ole; Wibig, Joanna; Wilcke, Renate; Kotlarski, Sven
2016-04-01
VALUE is an open European network to validate and compare downscaling methods for climate change research (http://www.value-cost.eu). A key deliverable of VALUE is the development of a systematic validation framework to enable the assessment and comparison of both dynamical and statistical downscaling methods. This framework is based on a user-focused validation tree, guiding the selection of relevant validation indices and performance measures for different aspects of the validation (marginal, temporal, spatial, multi-variable). Moreover, several experiments have been designed to isolate specific points in the downscaling procedure where problems may occur (assessment of intrinsic performance, effect of errors inherited from the global models, effect of non-stationarity, etc.). The list of downscaling experiments includes 1) cross-validation with perfect predictors, 2) GCM predictors -aligned with EURO-CORDEX experiment- and 3) pseudo reality predictors (see Maraun et al. 2015, Earth's Future, 3, doi:10.1002/2014EF000259, for more details). The results of these experiments are gathered, validated and publicly distributed through the VALUE validation portal, allowing for a comprehensive community-open downscaling intercomparison study. In this contribution we describe the overall results from Experiment 1), consisting of a European wide 5-fold cross-validation (with consecutive 6-year periods from 1979 to 2008) using predictors from ERA-Interim to downscale precipitation and temperatures (minimum and maximum) over a set of 86 ECA&D stations representative of the main geographical and climatic regions in Europe. As a result of the open call for contribution to this experiment (closed in Dec. 2015), over 40 methods representative of the main approaches (MOS and Perfect Prognosis, PP) and techniques (linear scaling, quantile mapping, analogs, weather typing, linear and generalized regression, weather generators, etc.) were submitted, including information both data (downscaled values) and metadata (characterizing different aspects of the downscaling methods). This constitutes the largest and most comprehensive to date intercomparison of statistical downscaling methods. Here, we present an overall validation, analyzing marginal and temporal aspects to assess the intrinsic performance and added value of statistical downscaling methods at both annual and seasonal levels. This validation takes into account the different properties/limitations of different approaches and techniques (as reported in the provided metadata) in order to perform a fair comparison. It is pointed out that this experiment alone is not sufficient to evaluate the limitations of (MOS) bias correction techniques. Moreover, it also does not fully validate PP since we don't learn whether we have the right predictors and whether the PP assumption is valid. These problems will be analyzed in the subsequent community-open VALUE experiments 2) and 3), which will be open for participation along the present year.
Thiex, Nancy J
2016-07-01
A previously validated method for the determination of both citrate-EDTA-soluble P and K and acid-soluble P and K in commercial inorganic fertilizers by inductively coupled plasma-optical emission spectrometry was submitted to the expert review panel (ERP) for fertilizers for consideration of First Action Official Method(SM) status. The ERP evaluated the single-laboratory validation results and recommended the method for First Action Official Method status and provided recommendations for achieving Final Action. Validation materials ranging from 4.4 to 52.4% P2O5 (1.7-22.7% P) and 3-62% K2O (2.5-51.1% K) were used for the validation. Recoveries from validation materials for citrate-soluble P and K ranged from 99.3 to 124.9% P and from 98.4 to 100.7% K. Recoveries from validation materials for acid-soluble "total" P and K ranged from 95.53 to 99.40% P and from 98.36 to 107.28% K. Values of r for citrate-soluble P and K, expressed as RSD, ranged from 0.28 to 1.30% for P and from 0.41 to 1.52% for K. Values of r for total P and K, expressed as RSD, ranged from 0.71 to 1.13% for P and from 0.39 to 1.18% for K. Based on the validation data, the ERP recommended the method (with alternatives for the citrate-soluble and the acid-soluble extractions) for First Action Official Method status and provided recommendations for achieving Final Action status.
DBS-LC-MS/MS assay for caffeine: validation and neonatal application.
Bruschettini, Matteo; Barco, Sebastiano; Romantsik, Olga; Risso, Francesco; Gennai, Iulian; Chinea, Benito; Ramenghi, Luca A; Tripodi, Gino; Cangemi, Giuliana
2016-09-01
DBS might be an appropriate microsampling technique for therapeutic drug monitoring of caffeine in infants. Nevertheless, its application presents several issues that still limit its use. This paper describes a validated DBS-LC-MS/MS method for caffeine. The results of the method validation showed an hematocrit dependence. In the analysis of 96 paired plasma and DBS clinical samples, caffeine levels measured in DBS were statistically significantly lower than in plasma but the observed differences were independent from hematocrit. These results clearly showed the need for extensive validation with real-life samples for DBS-based methods. DBS-LC-MS/MS can be considered to be a good alternative to traditional methods for therapeutic drug monitoring or PK studies in preterm infants.
Horn, W; Miksch, S; Egghart, G; Popow, C; Paky, F
1997-09-01
Real-time systems for monitoring and therapy planning, which receive their data from on-line monitoring equipment and computer-based patient records, require reliable data. Data validation has to utilize and combine a set of fast methods to detect, eliminate, and repair faulty data, which may lead to life-threatening conclusions. The strength of data validation results from the combination of numerical and knowledge-based methods applied to both continuously-assessed high-frequency data and discontinuously-assessed data. Dealing with high-frequency data, examining single measurements is not sufficient. It is essential to take into account the behavior of parameters over time. We present time-point-, time-interval-, and trend-based methods for validation and repair. These are complemented by time-independent methods for determining an overall reliability of measurements. The data validation benefits from the temporal data-abstraction process, which provides automatically derived qualitative values and patterns. The temporal abstraction is oriented on a context-sensitive and expectation-guided principle. Additional knowledge derived from domain experts forms an essential part for all of these methods. The methods are applied in the field of artificial ventilation of newborn infants. Examples from the real-time monitoring and therapy-planning system VIE-VENT illustrate the usefulness and effectiveness of the methods.
An integrated bioanalytical method development and validation approach: case studies.
Xue, Y-J; Melo, Brian; Vallejo, Martha; Zhao, Yuwen; Tang, Lina; Chen, Yuan-Shek; Keller, Karin M
2012-10-01
We proposed an integrated bioanalytical method development and validation approach: (1) method screening based on analyte's physicochemical properties and metabolism information to determine the most appropriate extraction/analysis conditions; (2) preliminary stability evaluation using both quality control and incurred samples to establish sample collection, storage and processing conditions; (3) mock validation to examine method accuracy and precision and incurred sample reproducibility; and (4) method validation to confirm the results obtained during method development. This integrated approach was applied to the determination of compound I in rat plasma and compound II in rat and dog plasma. The effectiveness of the approach was demonstrated by the superior quality of three method validations: (1) a zero run failure rate; (2) >93% of quality control results within 10% of nominal values; and (3) 99% incurred sample within 9.2% of the original values. In addition, rat and dog plasma methods for compound II were successfully applied to analyze more than 900 plasma samples obtained from Investigational New Drug (IND) toxicology studies in rats and dogs with near perfect results: (1) a zero run failure rate; (2) excellent accuracy and precision for standards and quality controls; and (3) 98% incurred samples within 15% of the original values. Copyright © 2011 John Wiley & Sons, Ltd.
Experimental design methodologies in the optimization of chiral CE or CEC separations: an overview.
Dejaegher, Bieke; Mangelings, Debby; Vander Heyden, Yvan
2013-01-01
In this chapter, an overview of experimental designs to develop chiral capillary electrophoresis (CE) and capillary electrochromatographic (CEC) methods is presented. Method development is generally divided into technique selection, method optimization, and method validation. In the method optimization part, often two phases can be distinguished, i.e., a screening and an optimization phase. In method validation, the method is evaluated on its fit for purpose. A validation item, also applying experimental designs, is robustness testing. In the screening phase and in robustness testing, screening designs are applied. During the optimization phase, response surface designs are used. The different design types and their application steps are discussed in this chapter and illustrated by examples of chiral CE and CEC methods.
Teaching method validation in the clinical laboratory science curriculum.
Moon, Tara C; Legrys, Vicky A
2008-01-01
With the Clinical Laboratory Improvement Amendment's (CLIA) final rule, the ability of the Clinical Laboratory Scientist (CLS) to perform method validation has become increasingly important. Knowledge of the statistical methods and procedures used in method validation is imperative for clinical laboratory scientists. However, incorporating these concepts in a CLS curriculum can be challenging, especially at a time of limited resources. This paper provides an outline of one approach to addressing these topics in lecture courses and integrating them in the student laboratory and the clinical practicum for direct application.
ERIC Educational Resources Information Center
Koskey, Kristin L. K.; Sondergeld, Toni A.; Stewart, Victoria C.; Pugh, Kevin J.
2018-01-01
Onwuegbuzie and colleagues proposed the Instrument Development and Construct Validation (IDCV) process as a mixed methods framework for creating and validating measures. Examples applying IDCV are lacking. We provide an illustrative case integrating the Rasch model and cognitive interviews applied to the development of the Transformative…
Validity of a digital diet estimation method for use with preschool children
USDA-ARS?s Scientific Manuscript database
The validity of using the Remote Food Photography Method (RFPM) for measuring food intake of minority preschool children's intake is not well documented. The aim of the study was to determine the validity of intake estimations made by human raters using the RFPM compared with those obtained by weigh...
Validating Accelerometry and Skinfold Measures in Youth with Down Syndrome
ERIC Educational Resources Information Center
Esposito, Phil Michael
2012-01-01
Current methods for measuring quantity and intensity of physical activity based on accelerometer output have been studied and validated in youth. These methods have been applied to youth with Down syndrome (DS) with no empirical research done to validate these measures. Similarly, individuals with DS have unique body proportions not represented by…
ERIC Educational Resources Information Center
Rahman, Nurulhuda Abd; Masuwai, Azwani; Tajudin, Nor'ain Mohd; Tek, Ong Eng; Adnan, Mazlini
2016-01-01
Purpose: This study was aimed at establishing, through the validation of the "Teaching and Learning Guiding Principles Instrument" (TLGPI), the validity and reliability of the underlying factor structure of the Teaching and Learning Guiding Principles (TLGP) generated by a previous study. Method: A survey method was used to collect data…
Double Cross-Validation in Multiple Regression: A Method of Estimating the Stability of Results.
ERIC Educational Resources Information Center
Rowell, R. Kevin
In multiple regression analysis, where resulting predictive equation effectiveness is subject to shrinkage, it is especially important to evaluate result replicability. Double cross-validation is an empirical method by which an estimate of invariance or stability can be obtained from research data. A procedure for double cross-validation is…
Analyzing the Validity of the Adult-Adolescent Parenting Inventory for Low-Income Populations
ERIC Educational Resources Information Center
Lawson, Michael A.; Alameda-Lawson, Tania; Byrnes, Edward
2017-01-01
Objectives: The purpose of this study was to examine the construct and predictive validity of the Adult-Adolescent Parenting Inventory (AAPI-2). Methods: The validity of the AAPI-2 was evaluated using multiple statistical methods, including exploratory factor analysis, confirmatory factor analysis, and latent class analysis. These analyses were…
Whelan, Maurice; Eskes, Chantra
Validation is essential for the translation of newly developed alternative approaches to animal testing into tools and solutions suitable for regulatory applications. Formal approaches to validation have emerged over the past 20 years or so and although they have helped greatly to progress the field, it is essential that the principles and practice underpinning validation continue to evolve to keep pace with scientific progress. The modular approach to validation should be exploited to encourage more innovation and flexibility in study design and to increase efficiency in filling data gaps. With the focus now on integrated approaches to testing and assessment that are based on toxicological knowledge captured as adverse outcome pathways, and which incorporate the latest in vitro and computational methods, validation needs to adapt to ensure it adds value rather than hinders progress. Validation needs to be pursued both at the method level, to characterise the performance of in vitro methods in relation their ability to detect any association of a chemical with a particular pathway or key toxicological event, and at the methodological level, to assess how integrated approaches can predict toxicological endpoints relevant for regulatory decision making. To facilitate this, more emphasis needs to be given to the development of performance standards that can be applied to classes of methods and integrated approaches that provide similar information. Moreover, the challenge of selecting the right reference chemicals to support validation needs to be addressed more systematically, consistently and in a manner that better reflects the state of the science. Above all however, validation requires true partnership between the development and user communities of alternative methods and the appropriate investment of resources.
Zietze, Stefan; Müller, Rainer H; Brecht, René
2008-03-01
In order to set up a batch-to-batch-consistency analytical scheme for N-glycosylation analysis, several sample preparation steps including enzyme digestions and fluorophore labelling and two HPLC-methods were established. The whole method scheme was standardized, evaluated and validated according to the requirements on analytical testing in early clinical drug development by usage of a recombinant produced reference glycoprotein (RGP). The standardization of the methods was performed by clearly defined standard operation procedures. During evaluation of the methods, the major interest was in the loss determination of oligosaccharides within the analytical scheme. Validation of the methods was performed with respect to specificity, linearity, repeatability, LOD and LOQ. Due to the fact that reference N-glycan standards were not available, a statistical approach was chosen to derive accuracy from the linearity data. After finishing the validation procedure, defined limits for method variability could be calculated and differences observed in consistency analysis could be separated into significant and incidental ones.
Patterson, Fiona; Lopes, Safiatu; Harding, Stephen; Vaux, Emma; Berkin, Liz; Black, David
2017-02-01
The aim of this study was to follow up a sample of physicians who began core medical training (CMT) in 2009. This paper examines the long-term validity of CMT and GP selection methods in predicting performance in the Membership of Royal College of Physicians (MRCP(UK)) examinations. We performed a longitudinal study, examining the extent to which the GP and CMT selection methods (T1) predict performance in the MRCP(UK) examinations (T2). A total of 2,569 applicants from 2008-09 who completed CMT and GP selection methods were included in the study. Looking at MRCP(UK) part 1, part 2 written and PACES scores, both CMT and GP selection methods show evidence of predictive validity for the outcome variables, and hierarchical regressions show the GP methods add significant value to the CMT selection process. CMT selection methods predict performance in important outcomes and have good evidence of validity; the GP methods may have an additional role alongside the CMT selection methods. © Royal College of Physicians 2017. All rights reserved.
Mousazadeh, Somayeh; Rakhshan, Mahnaz; Mohammadi, Fateme
2017-01-01
Objective: This study aimed to determine the psychometric properties of sociocultural attitude towards appearance questionnaire in female adolescents. Method: This was a methodological study. The English version of the questionnaire was translated into Persian, using forward-backward method. Then the face validity, content validity and reliability were checked. To ensure face validity, the questionnaire was given to 25 female adolescents, a psychologist and three nurses, who were required to evaluate the items with respect to problems, ambiguity, relativity, proper terms and grammar, and understandability. For content validity, 15 experts in psychology and nursing, who met the inclusion criteria, were required. They were asked to assess the qualitative of content validity. To determine the quantitative content validity, content validity index and content validity ratio were calculated. At the end, internal consistency of the items was assessed, using Cronbach’s alpha method. Results: According to the expert judgments, content validity ratio was 0.81 and content validity index was 0.91. Besides, the reliability of the questionnaire was confirmed with Cronbach’s alpha = 0.91, and physical and developmental areas showed the highest reliability indices. Conclusion: The aforementioned questionnaire could be used in researches to assess female adolescents’ self-concept. This can be a stepping-stone towards identification of problems and improvement of adolescents’ body image. PMID:28496497
Agogo, George O; van der Voet, Hilko; van 't Veer, Pieter; Ferrari, Pietro; Muller, David C; Sánchez-Cantalejo, Emilio; Bamia, Christina; Braaten, Tonje; Knüppel, Sven; Johansson, Ingegerd; van Eeuwijk, Fred A; Boshuizen, Hendriek C
2016-10-13
Measurement error in self-reported dietary intakes is known to bias the association between dietary intake and a health outcome of interest such as risk of a disease. The association can be distorted further by mismeasured confounders, leading to invalid results and conclusions. It is, however, difficult to adjust for the bias in the association when there is no internal validation data. We proposed a method to adjust for the bias in the diet-disease association (hereafter, association), due to measurement error in dietary intake and a mismeasured confounder, when there is no internal validation data. The method combines prior information on the validity of the self-report instrument with the observed data to adjust for the bias in the association. We compared the proposed method with the method that ignores the confounder effect, and with the method that ignores measurement errors completely. We assessed the sensitivity of the estimates to various magnitudes of measurement error, error correlations and uncertainty in the literature-reported validation data. We applied the methods to fruits and vegetables (FV) intakes, cigarette smoking (confounder) and all-cause mortality data from the European Prospective Investigation into Cancer and Nutrition study. Using the proposed method resulted in about four times increase in the strength of association between FV intake and mortality. For weakly correlated errors, measurement error in the confounder minimally affected the hazard ratio estimate for FV intake. The effect was more pronounced for strong error correlations. The proposed method permits sensitivity analysis on measurement error structures and accounts for uncertainties in the reported validity coefficients. The method is useful in assessing the direction and quantifying the magnitude of bias in the association due to measurement errors in the confounders.
Content Validity of National Post Marriage Educational Program Using Mixed Methods
MOHAJER RAHBARI, Masoumeh; SHARIATI, Mohammad; KERAMAT, Afsaneh; YUNESIAN, Masoud; ESLAMI, Mohammad; MOUSAVI, Seyed Abbas; MONTAZERI, Ali
2015-01-01
Background: Although the validity of content of program is mostly conducted with qualitative methods, this study used both qualitative and quantitative methods for the validation of content of post marriage training program provided for newly married couples. Content validity is a preliminary step of obtaining authorization required to install the program in country's health care system. Methods: This mixed methodological content validation study carried out in four steps with forming three expert panels. Altogether 24 expert panelists were involved in 3 qualitative and quantitative panels; 6 in the first item development one; 12 in the reduction kind, 4 of them were common with the first panel, and 10 executive experts in the last one organized to evaluate psychometric properties of CVR and CVI and Face validity of 57 educational objectives. Results: The raw data of post marriage program had been written by professional experts of Ministry of Health, using qualitative expert panel, the content was more developed by generating 3 topics and refining one topic and its respective content. In the second panel, totally six other objectives were deleted, three for being out of agreement cut of point and three on experts' consensus. The validity of all items was above 0.8 and their content validity indices (0.8–1) were completely appropriate in quantitative assessment. Conclusion: This study provided a good evidence for validation and accreditation of national post marriage program planned for newly married couples in health centers of the country in the near future. PMID:26056672
Moore, Tyler M.; Reise, Steven P.; Roalf, David R.; Satterthwaite, Theodore D.; Davatzikos, Christos; Bilker, Warren B.; Port, Allison M.; Jackson, Chad T.; Ruparel, Kosha; Savitt, Adam P.; Baron, Robert B.; Gur, Raquel E.; Gur, Ruben C.
2016-01-01
Traditional “paper-and-pencil” testing is imprecise in measuring speed and hence limited in assessing performance efficiency, but computerized testing permits precision in measuring itemwise response time. We present a method of scoring performance efficiency (combining information from accuracy and speed) at the item level. Using a community sample of 9,498 youths age 8-21, we calculated item-level efficiency scores on four neurocognitive tests, and compared the concurrent, convergent, discriminant, and predictive validity of these scores to simple averaging of standardized speed and accuracy-summed scores. Concurrent validity was measured by the scores' abilities to distinguish men from women and their correlations with age; convergent and discriminant validity were measured by correlations with other scores inside and outside of their neurocognitive domains; predictive validity was measured by correlations with brain volume in regions associated with the specific neurocognitive abilities. Results provide support for the ability of itemwise efficiency scoring to detect signals as strong as those detected by standard efficiency scoring methods. We find no evidence of superior validity of the itemwise scores over traditional scores, but point out several advantages of the former. The itemwise efficiency scoring method shows promise as an alternative to standard efficiency scoring methods, with overall moderate support from tests of four different types of validity. This method allows the use of existing item analysis methods and provides the convenient ability to adjust the overall emphasis of accuracy versus speed in the efficiency score, thus adjusting the scoring to the real-world demands the test is aiming to fulfill. PMID:26866796
Henry, Teresa R; Penn, Lara D; Conerty, Jason R; Wright, Francesca E; Gorman, Gregory; Pack, Brian W
2016-11-01
Non-clinical dose formulations (also known as pre-clinical or GLP formulations) play a key role in early drug development. These formulations are used to introduce active pharmaceutical ingredients (APIs) into test organisms for both pharmacokinetic and toxicological studies. Since these studies are ultimately used to support dose and safety ranges in human studies, it is important to understand not only the concentration and PK/PD of the active ingredient but also to generate safety data for likely process impurities and degradation products of the active ingredient. As such, many in the industry have chosen to develop and validate methods which can accurately detect and quantify the active ingredient along with impurities and degradation products. Such methods often provide trendable results which are predictive of stability, thus leading to the name; stability indicating methods. This document provides an overview of best practices for those choosing to include development and validation of such methods as part of their non-clinical drug development program. This document is intended to support teams who are either new to stability indicating method development and validation or who are less familiar with the requirements of validation due to their position within the product development life cycle.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Owens, J; Koester, C
The Environmental Protection Agency's (EPA) Region 5 Chicago Regional Laboratory (CRL) developed a method for analysis of aldicarb, bromadiolone, carbofuran, oxamyl, and methomyl in water by high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS), titled Method EPA MS666. This draft standard operating procedure (SOP) was distributed to multiple EPA laboratories and to Lawrence Livermore National Laboratory, which was tasked to serve as a reference laboratory for EPA's Environmental Reference Laboratory Network (ERLN) and to develop and validate analytical procedures. The primary objective of this study was to validate and verify the analytical procedures described in MS666 for analysis of carbamatemore » pesticides in aqueous samples. The gathered data from this validation study will be used to: (1) demonstrate analytical method performance; (2) generate quality control acceptance criteria; and (3) revise the SOP to provide a validated method that would be available for use during a homeland security event. The data contained in this report will be compiled, by EPA CRL, with data generated by other EPA Regional laboratories so that performance metrics of Method EPA MS666 can be determined.« less
A Comparison of Three Methods for the Analysis of Skin Flap Viability: Reliability and Validity.
Tim, Carla Roberta; Martignago, Cintia Cristina Santi; da Silva, Viviane Ribeiro; Dos Santos, Estefany Camila Bonfim; Vieira, Fabiana Nascimento; Parizotto, Nivaldo Antonio; Liebano, Richard Eloin
2018-05-01
Objective: Technological advances have provided new alternatives to the analysis of skin flap viability in animal models; however, the interrater validity and reliability of these techniques have yet to be analyzed. The present study aimed to evaluate the interrater validity and reliability of three different methods: weight of paper template (WPT), paper template area (PTA), and photographic analysis. Approach: Sixteen male Wistar rats had their cranially based dorsal skin flap elevated. On the seventh postoperative day, the viable tissue area and the necrotic area of the skin flap were recorded using the paper template method and photo image. The evaluation of the percentage of viable tissue was performed using three methods, simultaneously and independently by two raters. The analysis of interrater reliability and viability was performed using the intraclass correlation coefficient and Bland Altman Plot Analysis was used to visualize the presence or absence of systematic bias in the evaluations of data validity. Results: The results showed that interrater reliability for WPT, measurement of PTA, and photographic analysis were 0.995, 0.990, and 0.982, respectively. For data validity, a correlation >0.90 was observed for all comparisons made between the three methods. In addition, Bland Altman Plot Analysis showed agreement between the comparisons of the methods and the presence of systematic bias was not observed. Innovation: Digital methods are an excellent choice for assessing skin flap viability; moreover, they make data use and storage easier. Conclusion: Independently from the method used, the interrater reliability and validity proved to be excellent for the analysis of skin flaps' viability.
Netchacovitch, L; Thiry, J; De Bleye, C; Dumont, E; Cailletaud, J; Sacré, P-Y; Evrard, B; Hubert, Ph; Ziemons, E
2017-08-15
Since the Food and Drug Administration (FDA) published a guidance based on the Process Analytical Technology (PAT) approach, real-time analyses during manufacturing processes are in real expansion. In this study, in-line Raman spectroscopic analyses were performed during a Hot-Melt Extrusion (HME) process to determine the Active Pharmaceutical Ingredient (API) content in real-time. The method was validated based on a univariate and a multivariate approach and the analytical performances of the obtained models were compared. Moreover, on one hand, in-line data were correlated with the real API concentration present in the sample quantified by a previously validated off-line confocal Raman microspectroscopic method. On the other hand, in-line data were also treated in function of the concentration based on the weighing of the components in the prepared mixture. The importance of developing quantitative methods based on the use of a reference method was thus highlighted. The method was validated according to the total error approach fixing the acceptance limits at ±15% and the α risk at ±5%. This method reaches the requirements of the European Pharmacopeia norms for the uniformity of content of single-dose preparations. The validation proves that future results will be in the acceptance limits with a previously defined probability. Finally, the in-line validated method was compared with the off-line one to demonstrate its ability to be used in routine analyses. Copyright © 2017 Elsevier B.V. All rights reserved.
2018-01-01
A simple, sensitive, accurate, robust headspace gas chromatographic method was developed for the quantitative determination of acetone and isopropyl alcohol in tartaric acid-based pellets of dipyridamole modified release capsules. The residual solvents acetone and isopropyl alcohol were used in the manufacturing process of the tartaric acid-based pellets of dipyridamole modified release capsules by considering the solubility of the dipyridamole and excipients in the different manufacturing stages. The method was developed and optimized by using fused silica DB-624 (30 m × 0.32 mm × 1.8 µm) column with the flame ionization detector. The method validation was carried out with regard to the guidelines for validation of analytical procedures Q2 demanded by the International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use (ICH). All the validation characteristics were meeting the acceptance criteria. Hence, the developed and validated method can be applied for the intended routine analysis. PMID:29686931
Valavala, Sriram; Seelam, Nareshvarma; Tondepu, Subbaiah; Jagarlapudi, V Shanmukha Kumar; Sundarmurthy, Vivekanandan
2018-01-01
A simple, sensitive, accurate, robust headspace gas chromatographic method was developed for the quantitative determination of acetone and isopropyl alcohol in tartaric acid-based pellets of dipyridamole modified release capsules. The residual solvents acetone and isopropyl alcohol were used in the manufacturing process of the tartaric acid-based pellets of dipyridamole modified release capsules by considering the solubility of the dipyridamole and excipients in the different manufacturing stages. The method was developed and optimized by using fused silica DB-624 (30 m × 0.32 mm × 1.8 µ m) column with the flame ionization detector. The method validation was carried out with regard to the guidelines for validation of analytical procedures Q2 demanded by the International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use (ICH). All the validation characteristics were meeting the acceptance criteria. Hence, the developed and validated method can be applied for the intended routine analysis.
Gowda, Nagaraj; Kumar, Pradeep; Panghal, Surender; Rajshree, Mashru
2010-02-01
This study presents the development and validation of a reversed-phase liquid chromatographic method for the determination of mangiferin (MGN) in alcoholic extracts of mangifera indica. A Lichrospher 100 C(18)-ODS (250 x 4.6 mm, 5 microm size) (Merck, Whitehouse Station, NJ) prepacked column and a mobile phase of potassium dihydrogen orthophosphate (0.01M) pH 2.7 +/- 0.2-acetonitrile (15:85, v/v) with the flow rate of 1 mL/min was used. MGN detection was achieved at a wavelength monitored at 254 nm with SPD-M 10A vp PDA detector or SPD 10AD vp UV detector in combination with class LC 10A software. The proposed method was validated as prescribed by International Conference on Harmonization (ICH) with respect to linearity, specificity, accuracy, precision, stability, and quantification. The method validation was realized using alcoholic extracts and raw materials of leaves and barks. All the validation parameters were within the acceptable limits, and the developed analytical method can successfully be applied for MGN determination.
A multivariate model and statistical method for validating tree grade lumber yield equations
Donald W. Seegrist
1975-01-01
Lumber yields within lumber grades can be described by a multivariate linear model. A method for validating lumber yield prediction equations when there are several tree grades is presented. The method is based on multivariate simultaneous test procedures.
Validation of Skills, Knowledge and Experience in Lifelong Learning in Europe
ERIC Educational Resources Information Center
Ogunleye, James
2012-01-01
The paper examines systems of validation of skills and experience as well as the main methods/tools currently used for validating skills and knowledge in lifelong learning. The paper uses mixed methods--a case study research and content analysis of European Union policy documents and frameworks--as a basis for this research. The selection of the…
Evaluating the Social Validity of the Early Start Denver Model: A Convergent Mixed Methods Study
ERIC Educational Resources Information Center
Ogilvie, Emily; McCrudden, Matthew T.
2017-01-01
An intervention has social validity to the extent that it is socially acceptable to participants and stakeholders. This pilot convergent mixed methods study evaluated parents' perceptions of the social validity of the Early Start Denver Model (ESDM), a naturalistic behavioral intervention for children with autism. It focused on whether the parents…
40 CFR Appendix D to Part 63 - Alternative Validation Procedure for EPA Waste and Wastewater Methods
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 14 2010-07-01 2010-07-01 false Alternative Validation Procedure for EPA Waste and Wastewater Methods D Appendix D to Part 63 Protection of Environment ENVIRONMENTAL... POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) Pt. 63, App. D Appendix D to Part 63—Alternative Validation...
40 CFR Appendix D to Part 63 - Alternative Validation Procedure for EPA Waste and Wastewater Methods
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 14 2011-07-01 2011-07-01 false Alternative Validation Procedure for EPA Waste and Wastewater Methods D Appendix D to Part 63 Protection of Environment ENVIRONMENTAL... POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) Pt. 63, App. D Appendix D to Part 63—Alternative Validation...
40 CFR Appendix D to Part 63 - Alternative Validation Procedure for EPA Waste and Wastewater Methods
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 15 2014-07-01 2014-07-01 false Alternative Validation Procedure for EPA Waste and Wastewater Methods D Appendix D to Part 63 Protection of Environment ENVIRONMENTAL... POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) Pt. 63, App. D Appendix D to Part 63—Alternative Validation...
40 CFR Appendix D to Part 63 - Alternative Validation Procedure for EPA Waste and Wastewater Methods
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 15 2013-07-01 2013-07-01 false Alternative Validation Procedure for EPA Waste and Wastewater Methods D Appendix D to Part 63 Protection of Environment ENVIRONMENTAL... POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) Pt. 63, App. D Appendix D to Part 63—Alternative Validation...
40 CFR Appendix D to Part 63 - Alternative Validation Procedure for EPA Waste and Wastewater Methods
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 15 2012-07-01 2012-07-01 false Alternative Validation Procedure for EPA Waste and Wastewater Methods D Appendix D to Part 63 Protection of Environment ENVIRONMENTAL... POLLUTANTS FOR SOURCE CATEGORIES (CONTINUED) Pt. 63, App. D Appendix D to Part 63—Alternative Validation...
ERIC Educational Resources Information Center
Miciak, Jeremy; Fletcher, Jack M.; Stuebing, Karla K.; Vaughn, Sharon; Tolar, Tammy D.
2014-01-01
Few empirical investigations have evaluated learning disabilities (LD) identification methods based on a pattern of cognitive strengths and weaknesses (PSW). This study investigated the reliability and validity of two proposed PSW methods: the concordance/discordance method (C/DM) and cross battery assessment (XBA) method. Cognitive assessment…
Ruuska, Salla; Hämäläinen, Wilhelmiina; Kajava, Sari; Mughal, Mikaela; Matilainen, Pekka; Mononen, Jaakko
2018-03-01
The aim of the present study was to evaluate empirically confusion matrices in device validation. We compared the confusion matrix method to linear regression and error indices in the validation of a device measuring feeding behaviour of dairy cattle. In addition, we studied how to extract additional information on classification errors with confusion probabilities. The data consisted of 12 h behaviour measurements from five dairy cows; feeding and other behaviour were detected simultaneously with a device and from video recordings. The resulting 216 000 pairs of classifications were used to construct confusion matrices and calculate performance measures. In addition, hourly durations of each behaviour were calculated and the accuracy of measurements was evaluated with linear regression and error indices. All three validation methods agreed when the behaviour was detected very accurately or inaccurately. Otherwise, in the intermediate cases, the confusion matrix method and error indices produced relatively concordant results, but the linear regression method often disagreed with them. Our study supports the use of confusion matrix analysis in validation since it is robust to any data distribution and type of relationship, it makes a stringent evaluation of validity, and it offers extra information on the type and sources of errors. Copyright © 2018 Elsevier B.V. All rights reserved.
Sanagi, M Marsin; Nasir, Zalilah; Ling, Susie Lu; Hermawan, Dadan; Ibrahim, Wan Aini Wan; Naim, Ahmedy Abu
2010-01-01
Linearity assessment as required in method validation has always been subject to different interpretations and definitions by various guidelines and protocols. However, there are very limited applicable implementation procedures that can be followed by a laboratory chemist in assessing linearity. Thus, this work proposes a simple method for linearity assessment in method validation by a regression analysis that covers experimental design, estimation of the parameters, outlier treatment, and evaluation of the assumptions according to the International Union of Pure and Applied Chemistry guidelines. The suitability of this procedure was demonstrated by its application to an in-house validation for the determination of plasticizers in plastic food packaging by GC.
NASA Technical Reports Server (NTRS)
Thompson, David E.
2005-01-01
Procedures and methods for veri.cation of coding algebra and for validations of models and calculations used in the aerospace computational fluid dynamics (CFD) community would be ef.cacious if used by the glacier dynamics modeling community. This paper presents some of those methods, and how they might be applied to uncertainty management supporting code veri.cation and model validation for glacier dynamics. The similarities and differences between their use in CFD analysis and the proposed application of these methods to glacier modeling are discussed. After establishing sources of uncertainty and methods for code veri.cation, the paper looks at a representative sampling of veri.cation and validation efforts that are underway in the glacier modeling community, and establishes a context for these within an overall solution quality assessment. Finally, a vision of a new information architecture and interactive scienti.c interface is introduced and advocated.
Wang, Zhenlei; Jiang, Ji; Hu, Pei; Zhao, Qian
2017-02-01
Fotagliptin is a novel dipeptidyl peptidase IV inhibitor under clinical development for the treatment of Type II diabetes mellitus. The objective of this study was to develop and validate a specific and sensitive ultra-performance liquid chromatography (UPLC)-MS/MS method for simultaneous determination of fotagliptin and its two major metabolites in human plasma and urine. Methodology & results: After being pretreated using an automatized procedure, the plasma and urine samples were separated and detected using a UPLC-ESI-MS/MS method, which was validated following the international guidelines. A selective and sensitive UPLC-MS/MS method was first developed and validated for quantifying fotagliptin and its metabolite in human plasma and urine. The method was successfully applied to support the clinical study of fotagliptin in Chinese healthy subjects.
A brief measure of attitudes toward mixed methods research in psychology
Roberts, Lynne D.; Povee, Kate
2014-01-01
The adoption of mixed methods research in psychology has trailed behind other social science disciplines. Teaching psychology students, academics, and practitioners about mixed methodologies may increase the use of mixed methods within the discipline. However, tailoring and evaluating education and training in mixed methodologies requires an understanding of, and way of measuring, attitudes toward mixed methods research in psychology. To date, no such measure exists. In this article we present the development and initial validation of a new measure: Attitudes toward Mixed Methods Research in Psychology. A pool of 42 items developed from previous qualitative research on attitudes toward mixed methods research along with validation measures was administered via an online survey to a convenience sample of 274 psychology students, academics and psychologists. Principal axis factoring with varimax rotation on a subset of the sample produced a four-factor, 12-item solution. Confirmatory factor analysis on a separate subset of the sample indicated that a higher order four factor model provided the best fit to the data. The four factors; ‘Limited Exposure,’ ‘(in)Compatibility,’ ‘Validity,’ and ‘Tokenistic Qualitative Component’; each have acceptable internal reliability. Known groups validity analyses based on preferred research orientation and self-rated mixed methods research skills, and convergent and divergent validity analyses based on measures of attitudes toward psychology as a science and scientist and practitioner orientation, provide initial validation of the measure. This brief, internally reliable measure can be used in assessing attitudes toward mixed methods research in psychology, measuring change in attitudes as part of the evaluation of mixed methods education, and in larger research programs. PMID:25429281
Winzer, Eva; Luger, Maria; Schindler, Karin
2018-06-01
Regular monitoring of food intake is hardly integrated in clinical routine. Therefore, the aim was to examine the validity, accuracy, and applicability of an appropriate and also quick and easy-to-use tool for recording food intake in a clinical setting. Two digital photography methods, the postMeal method with a picture after the meal, the pre-postMeal method with a picture before and after the meal, and the visual estimation method (plate diagram; PD) were compared against the reference method (weighed food records; WFR). A total of 420 dishes from lunch (7 weeks) were estimated with both photography methods and the visual method. Validity, applicability, accuracy, and precision of the estimation methods, and additionally food waste, macronutrient composition, and energy content were examined. Tests of validity revealed stronger correlations for photography methods (postMeal: r = 0.971, p < 0.001; pre-postMeal: r = 0.995, p < 0.001) compared to the visual estimation method (r = 0.810; p < 0.001). The pre-postMeal method showed smaller variability (bias < 1 g) and also smaller overestimation and underestimation. This method accurately and precisely estimated portion sizes in all food items. Furthermore, the total food waste was 22% for lunch over the study period. The highest food waste was observed in salads and the lowest in desserts. The pre-postMeal digital photography method is valid, accurate, and applicable in monitoring food intake in clinical setting, which enables a quantitative and qualitative dietary assessment. Thus, nutritional care might be initiated earlier. This method might be also advantageous for quantitative and qualitative evaluation of food waste, with a resultantly reduction in costs.
Patel, Jayshree; Mulhall, Brian; Wolf, Heinz; Klohr, Steven; Guazzo, Dana Morton
2011-01-01
A leak test performed according to ASTM F2338-09 Standard Test Method for Nondestructive Detection of Leaks in Packages by Vacuum Decay Method was developed and validated for container-closure integrity verification of a lyophilized product in a parenteral vial package system. This nondestructive leak test method is intended for use in manufacturing as an in-process package integrity check, and for testing product stored on stability in lieu of sterility tests. Method development and optimization challenge studies incorporated artificially defective packages representing a range of glass vial wall and sealing surface defects, as well as various elastomeric stopper defects. Method validation required 3 days of random-order replicate testing of a test sample population of negative-control, no-defect packages and positive-control, with-defect packages. Positive-control packages were prepared using vials each with a single hole laser-drilled through the glass vial wall. Hole creation and hole size certification was performed by Lenox Laser. Validation study results successfully demonstrated the vacuum decay leak test method's ability to accurately and reliably detect those packages with laser-drilled holes greater than or equal to approximately 5 μm in nominal diameter. All development and validation studies were performed at Whitehouse Analytical Laboratories in Whitehouse, NJ, under the direction of consultant Dana Guazzo of RxPax, LLC, using a VeriPac 455 Micro Leak Test System by Packaging Technologies & Inspection (Tuckahoe, NY). Bristol Myers Squibb (New Brunswick, NJ) fully subsidized all work. A leak test performed according to ASTM F2338-09 Standard Test Method for Nondestructive Detection of Leaks in Packages by Vacuum Decay Method was developed and validated to detect defects in stoppered vial packages containing lyophilized product for injection. This nondestructive leak test method is intended for use in manufacturing as an in-process package integrity check, and for testing product stored on stability in lieu of sterility tests. Test method validation study results proved the method capable of detecting holes laser-drilled through the glass vial wall greater than or equal to 5 μm in nominal diameter. Total test time is less than 1 min per package. All method development and validation studies were performed at Whitehouse Analytical Laboratories in Whitehouse, NJ, under the direction of consultant Dana Guazzo of RxPax, LLC, using a VeriPac 455 Micro Leak Test System by Packaging Technologies & Inspection (Tuckahoe, NY). Bristol Myers Squibb (New Brunswick, NJ) fully subsidized all work.
NASA Technical Reports Server (NTRS)
Duncan, L. M.; Reddell, J. P.; Schoonmaker, P. B.
1975-01-01
Techniques and support software for the efficient performance of simulation validation are discussed. Overall validation software structure, the performance of validation at various levels of simulation integration, guidelines for check case formulation, methods for real time acquisition and formatting of data from an all up operational simulator, and methods and criteria for comparison and evaluation of simulation data are included. Vehicle subsystems modules, module integration, special test requirements, and reference data formats are also described.
Empirical Performance of Cross-Validation With Oracle Methods in a Genomics Context
Martinez, Josue G.; Carroll, Raymond J.; Müller, Samuel; Sampson, Joshua N.; Chatterjee, Nilanjan
2012-01-01
When employing model selection methods with oracle properties such as the smoothly clipped absolute deviation (SCAD) and the Adaptive Lasso, it is typical to estimate the smoothing parameter by m-fold cross-validation, for example, m = 10. In problems where the true regression function is sparse and the signals large, such cross-validation typically works well. However, in regression modeling of genomic studies involving Single Nucleotide Polymorphisms (SNP), the true regression functions, while thought to be sparse, do not have large signals. We demonstrate empirically that in such problems, the number of selected variables using SCAD and the Adaptive Lasso, with 10-fold cross-validation, is a random variable that has considerable and surprising variation. Similar remarks apply to non-oracle methods such as the Lasso. Our study strongly questions the suitability of performing only a single run of m-fold cross-validation with any oracle method, and not just the SCAD and Adaptive Lasso. PMID:22347720
STATISTICAL VALIDATION OF SULFATE QUANTIFICATION METHODS USED FOR ANALYSIS OF ACID MINE DRAINAGE
Turbidimetric method (TM), ion chromatography (IC) and inductively coupled plasma atomic emission spectrometry (ICP-AES) with and without acid digestion have been compared and validated for the determination of sulfate in mining wastewater. Analytical methods were chosen to compa...
NASA Astrophysics Data System (ADS)
Ulu, Sevgi Tatar; Elmali, Fikriye Tuncel
2012-03-01
A novel, selective, sensitive and simple spectrophotometric method was developed and validated for the determination of the antidepressant duloxetine hydrochloride in pharmaceutical preparation. The method was based on the reaction of duloxetine hydrochloride with 1,2-naphthoquinone-4-sulphonate (NQS) in alkaline media to yield orange colored product. The formation of this complex was also confirmed by UV-visible, FTIR, 1H NMR, Mass spectra techniques and thermal analysis. This method was validated for various parameters according to ICH guidelines. Beer's law is obeyed in a range of 5.0-60 μg/mL at the maximum absorption wavelength of 480 nm. The detection limit is 0.99 μg/mL and the recovery rate is in a range of 98.10-99.57%. The proposed methods was validated and applied to the determination of duloxetine hydrochloride in pharmaceutical preparation. The results were statistically analyzed and compared to those of a reference UV spectrophotometric method.
[Validation and verfication of microbiology methods].
Camaró-Sala, María Luisa; Martínez-García, Rosana; Olmos-Martínez, Piedad; Catalá-Cuenca, Vicente; Ocete-Mochón, María Dolores; Gimeno-Cardona, Concepción
2015-01-01
Clinical microbiologists should ensure, to the maximum level allowed by the scientific and technical development, the reliability of the results. This implies that, in addition to meeting the technical criteria to ensure their validity, they must be performed with a number of conditions that allows comparable results to be obtained, regardless of the laboratory that performs the test. In this sense, the use of recognized and accepted reference methodsis the most effective tool for these guarantees. The activities related to verification and validation of analytical methods has become very important, as there is continuous development, as well as updating techniques and increasingly complex analytical equipment, and an interest of professionals to ensure quality processes and results. The definitions of validation and verification are described, along with the different types of validation/verification, and the types of methods, and the level of validation necessary depending on the degree of standardization. The situations in which validation/verification is mandatory and/or recommended is discussed, including those particularly related to validation in Microbiology. It stresses the importance of promoting the use of reference strains as controls in Microbiology and the use of standard controls, as well as the importance of participation in External Quality Assessment programs to demonstrate technical competence. The emphasis is on how to calculate some of the parameters required for validation/verification, such as the accuracy and precision. The development of these concepts can be found in the microbiological process SEIMC number 48: «Validation and verification of microbiological methods» www.seimc.org/protocols/microbiology. Copyright © 2013 Elsevier España, S.L.U. y Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.
Multiple Versus Single Set Validation of Multivariate Models to Avoid Mistakes.
Harrington, Peter de Boves
2018-01-02
Validation of multivariate models is of current importance for a wide range of chemical applications. Although important, it is neglected. The common practice is to use a single external validation set for evaluation. This approach is deficient and may mislead investigators with results that are specific to the single validation set of data. In addition, no statistics are available regarding the precision of a derived figure of merit (FOM). A statistical approach using bootstrapped Latin partitions is advocated. This validation method makes an efficient use of the data because each object is used once for validation. It was reviewed a decade earlier but primarily for the optimization of chemometric models this review presents the reasons it should be used for generalized statistical validation. Average FOMs with confidence intervals are reported and powerful, matched-sample statistics may be applied for comparing models and methods. Examples demonstrate the problems with single validation sets.
Getts, Katherine M; Quinn, Emilee L; Johnson, Donna B; Otten, Jennifer J
2017-11-01
Measuring food waste (ie, plate waste) in school cafeterias is an important tool to evaluate the effectiveness of school nutrition policies and interventions aimed at increasing consumption of healthier meals. Visual assessment methods are frequently applied in plate waste studies because they are more convenient than weighing. The visual quarter-waste method has become a common tool in studies of school meal waste and consumption, but previous studies of its validity and reliability have used correlation coefficients, which measure association but not necessarily agreement. The aims of this study were to determine, using a statistic measuring interrater agreement, whether the visual quarter-waste method is valid and reliable for assessing food waste in a school cafeteria setting when compared with the gold standard of weighed plate waste. To evaluate validity, researchers used the visual quarter-waste method and weighed food waste from 748 trays at four middle schools and five high schools in one school district in Washington State during May 2014. To assess interrater reliability, researcher pairs independently assessed 59 of the same trays using the visual quarter-waste method. Both validity and reliability were assessed using a weighted κ coefficient. For validity, as compared with the measured weight, 45% of foods assessed using the visual quarter-waste method were in almost perfect agreement, 42% of foods were in substantial agreement, 10% were in moderate agreement, and 3% were in slight agreement. For interrater reliability between pairs of visual assessors, 46% of foods were in perfect agreement, 31% were in almost perfect agreement, 15% were in substantial agreement, and 8% were in moderate agreement. These results suggest that the visual quarter-waste method is a valid and reliable tool for measuring plate waste in school cafeteria settings. Copyright © 2017 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Lau, Wilfred W. F.; Yuen, Allan H. K.
2009-01-01
Recent years have seen a shift in focus from assessment of learning to assessment for learning and the emergence of alternative assessment methods. However, the reliability and validity of these methods as assessment tools are still questionable. In this article, we investigated the predictive validity of measures of the Pathfinder Scaling…
Validation of an Instrument to Measure High School Students' Attitudes toward Fitness Testing
ERIC Educational Resources Information Center
Mercier, Kevin; Silverman, Stephen
2014-01-01
Purpose: The purpose of this investigation was to develop an instrument that has scores that are valid and reliable for measuring students' attitudes toward fitness testing. Method: The method involved the following steps: (a) an elicitation study, (b) item development, (c) a pilot study, and (d) a validation study. The pilot study included 427…
Sensitivity-Uncertainty Based Nuclear Criticality Safety Validation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, Forrest B.
2016-09-20
These are slides from a seminar given to the University of Mexico Nuclear Engineering Department. Whisper is a statistical analysis package developed to support nuclear criticality safety validation. It uses the sensitivity profile data for an application as computed by MCNP6 along with covariance files for the nuclear data to determine a baseline upper-subcritical-limit for the application. Whisper and its associated benchmark files are developed and maintained as part of MCNP6, and will be distributed with all future releases of MCNP6. Although sensitivity-uncertainty methods for NCS validation have been under development for 20 years, continuous-energy Monte Carlo codes such asmore » MCNP could not determine the required adjoint-weighted tallies for sensitivity profiles. The recent introduction of the iterated fission probability method into MCNP led to the rapid development of sensitivity analysis capabilities for MCNP6 and the development of Whisper. Sensitivity-uncertainty based methods represent the future for NCS validation – making full use of today’s computer power to codify past approaches based largely on expert judgment. Validation results are defensible, auditable, and repeatable as needed with different assumptions and process models. The new methods can supplement, support, and extend traditional validation approaches.« less
Validation of laboratory-scale recycling test method of paper PSA label products
Carl Houtman; Karen Scallon; Richard Oldack
2008-01-01
Starting with test methods and a specification developed by the U.S. Postal Service (USPS) Environmentally Benign Pressure Sensitive Adhesive Postage Stamp Program, a laboratory-scale test method and a specification were developed and validated for pressure-sensitive adhesive labels, By comparing results from this new test method and pilot-scale tests, which have been...
The Method Effect in Communicative Testing.
ERIC Educational Resources Information Center
Canale, Michael
1981-01-01
A focus on test validity includes a consideration of the way a test measures that which it proposes to test; in other words, the validity of a test depends on method as well as content. This paper examines three areas of concern: (1) some features of communication that test method should reflect, (2) the main components of method, and (3) some…
Introduction to Validation of Analytical Methods: Potentiometric Determination of CO[subscript 2
ERIC Educational Resources Information Center
Hipólito-Nájera, A. Ricardo; Moya-Hernandez, M. Rosario; Gomez-Balderas, Rodolfo; Rojas-Hernandez, Alberto; Romero-Romo, Mario
2017-01-01
Validation of analytical methods is a fundamental subject for chemical analysts working in chemical industries. These methods are also relevant for pharmaceutical enterprises, biotechnology firms, analytical service laboratories, government departments, and regulatory agencies. Therefore, for undergraduate students enrolled in majors in the field…
Kulikov, A U; Zinchenko, A A
2007-02-19
This paper describes the validation of an isocratic HPLC method for the assay of dexpanthenol in aerosol and gel. The method employs the Vydac Proteins C4 column with a mobile phase of aqueous solution of trifluoroacetic acid and UV detection at 206 nm. A linear response (r>0.9999) was observed in the range of 13.0-130 microg mL(-1). The method shows good recoveries and intra and inter-day relative standard deviations were less than 1.0%. Validation parameters as specificity, accuracy and robustness were also determined. The method can be used for dexpanthenol assay of panthenol aerosol and gel with dexpanthenol as the method separates dexpanthenol from aerosol or gel excipients.
Ibrahim, Fawzia; El-Enany, Nahed; Shalan, Shereen; Elsharawy, Rasha
2016-05-01
A simple, highly sensitive and validated spectrofluorimetric method was applied in the determination of clonazepam (CLZ). The method is based on reduction of the nitro group of clonazepam with zinc/CaCl2, and the product is then reacted with 2-cyanoacetamide (2-CNA) in the presence of ammonia (25%) yielding a highly fluorescent product. The produced fluorophore exhibits strong fluorescence intensity at ʎ(em) = 383 nm after excitation at ʎ(ex) = 333 nm. The method was rectilinear over a concentration range of 0.1-0.5 ng/mL with a limit of detection (LOD) of 0.0057 ng/mL and a limit of quantification (LOQ) of 0.017 ng/mL. The method was fully validated and successfully applied to the determination of CLZ in its tablets with a mean percentage recovery of 100.10 ± 0.75%. Method validation according to ICH Guidelines was evaluated. Statistical analysis of the results obtained using the proposed method was successfully compared with those obtained using a reference method, and there was no significance difference between the two methods in terms of accuracy and precision. Copyright © 2015 John Wiley & Sons, Ltd.
Graf, Tyler N; Cech, Nadja B; Polyak, Stephen J; Oberlies, Nicholas H
2016-07-15
Validated methods are needed for the analysis of natural product secondary metabolites. These methods are particularly important to translate in vitro observations to in vivo studies. Herein, a method is reported for the analysis of the key secondary metabolites, a series of flavonolignans and a flavonoid, from an extract prepared from the seeds of milk thistle [Silybum marianum (L.) Gaertn. (Asteraceae)]. This report represents the first UHPLC MS-MS method validated for quantitative analysis of these compounds. The method takes advantage of the excellent resolution achievable with UHPLC to provide a complete analysis in less than 7min. The method is validated using both UV and MS detectors, making it applicable in laboratories with different types of analytical instrumentation available. Lower limits of quantitation achieved with this method range from 0.0400μM to 0.160μM with UV and from 0.0800μM to 0.160μM with MS. The new method is employed to evaluate variability in constituent composition in various commercial S. marianum extracts, and to show that storage of the milk thistle compounds in DMSO leads to degradation. Copyright © 2016 Elsevier B.V. All rights reserved.
In 't Veld, P H; van der Laak, L F J; van Zon, M; Biesta-Peters, E G
2018-04-12
A method for the quantification of the Bacillus cereus emetic toxin (cereulide) was developed and validated. The method principle is based on LC-MS as this is the most sensitive and specific method for cereulide. Therefore the study design is different from the microbiological methods validated under this mandate. As the method had to be developed a two stage validation study approach was used. The first stage (pre-study) focussed on the method applicability and the experience of the laboratories with the method. Based on the outcome of the pre-study and comments received during voting at CEN and ISO level a final method was agreed to be used for the second stage the (final) validation of the method. In the final (validation) study samples of cooked rice (both artificially contaminated with cereulide or contaminated with B. cereus for production of cereulide in the rice) and 6 other food matrices (fried rice dish, cream pastry with chocolate, hotdog sausage, mini pancakes, vanilla custard and infant formula) were used. All these samples were spiked by the participating laboratories using standard solutions of cereulide supplied by the organising laboratory. The results of the study indicate that the method is fit for purpose. Repeatability values were obtained of 0.6 μg/kg at low level spike (ca. 5 μg/kg) and 7 to 9.6 μg/kg at high level spike (ca. 75 μg/kg). Reproducibility at low spike level ranged from 0.6 to 0.9 μg/kg and from 8.7 to 14.5 μg/kg at high spike level. Recovery from the spiked samples ranged between 96.5% for mini-pancakes to 99.3% for fries rice dish. Copyright © 2018. Published by Elsevier B.V.
[Data validation methods and discussion on Chinese materia medica resource survey].
Zhang, Yue; Ma, Wei-Feng; Zhang, Xiao-Bo; Zhu, Shou-Dong; Guo, Lan-Ping; Wang, Xing-Xing
2013-07-01
From the beginning of the fourth national survey of the Chinese materia medica resources, there were 22 provinces have conducted pilots. The survey teams have reported immense data, it put forward the very high request to the database system construction. In order to ensure the quality, it is necessary to check and validate the data in database system. Data validation is important methods to ensure the validity, integrity and accuracy of census data. This paper comprehensively introduce the data validation system of the fourth national survey of the Chinese materia medica resources database system, and further improve the design idea and programs of data validation. The purpose of this study is to promote the survey work smoothly.
Validation of spatial variability in downscaling results from the VALUE perfect predictor experiment
NASA Astrophysics Data System (ADS)
Widmann, Martin; Bedia, Joaquin; Gutiérrez, Jose Manuel; Maraun, Douglas; Huth, Radan; Fischer, Andreas; Keller, Denise; Hertig, Elke; Vrac, Mathieu; Wibig, Joanna; Pagé, Christian; Cardoso, Rita M.; Soares, Pedro MM; Bosshard, Thomas; Casado, Maria Jesus; Ramos, Petra
2016-04-01
VALUE is an open European network to validate and compare downscaling methods for climate change research. Within VALUE a systematic validation framework to enable the assessment and comparison of both dynamical and statistical downscaling methods has been developed. In the first validation experiment the downscaling methods are validated in a setup with perfect predictors taken from the ERA-interim reanalysis for the period 1997 - 2008. This allows to investigate the isolated skill of downscaling methods without further error contributions from the large-scale predictors. One aspect of the validation is the representation of spatial variability. As part of the VALUE validation we have compared various properties of the spatial variability of downscaled daily temperature and precipitation with the corresponding properties in observations. We have used two test validation datasets, one European-wide set of 86 stations, and one higher-density network of 50 stations in Germany. Here we present results based on three approaches, namely the analysis of i.) correlation matrices, ii.) pairwise joint threshold exceedances, and iii.) regions of similar variability. We summarise the information contained in correlation matrices by calculating the dependence of the correlations on distance and deriving decorrelation lengths, as well as by determining the independent degrees of freedom. Probabilities for joint threshold exceedances and (where appropriate) non-exceedances are calculated for various user-relevant thresholds related for instance to extreme precipitation or frost and heat days. The dependence of these probabilities on distance is again characterised by calculating typical length scales that separate dependent from independent exceedances. Regionalisation is based on rotated Principal Component Analysis. The results indicate which downscaling methods are preferable if the dependency of variability at different locations is relevant for the user.
de By, Theo M M H; McDonald, Carl; Süßner, Susanne; Davies, Jill; Heng, Wee Ling; Jashari, Ramadan; Bogers, Ad J J C; Petit, Pieter
2017-11-01
Surgeons needing human cardiovascular tissue for implantation in their patients are confronted with cardiovascular tissue banks that use different methods to identify and decontaminate micro-organisms. To elucidate these differences, we compared the quality of processing methods in 20 tissue banks and 1 reference laboratory. We did this to validate the results for accepting or rejecting tissue. We included the decontamination methods used and the influence of antibiotic cocktails and residues with results and controls. The minor details of the processes were not included. To compare the outcomes of microbiological testing and decontamination methods of heart valve allografts in cardiovascular tissue banks, an international quality round was organized. Twenty cardiovascular tissue banks participated in this quality round. The quality round method was validated first and consisted of sending purposely contaminated human heart valve tissue samples with known micro-organisms to the participants. The participants identified the micro-organisms using their local decontamination methods. Seventeen of the 20 participants correctly identified the micro-organisms; if these samples were heart valves to be released for implantation, 3 of the 20 participants would have decided to accept their result for release. Decontamination was shown not to be effective in 13 tissue banks because of growth of the organisms after decontamination. Articles in the literature revealed that antibiotics are effective at 36°C and not, or less so, at 2-8°C. The decontamination procedure, if it is validated, will ensure that the tissue contains no known micro-organisms. This study demonstrates that the quality round method of sending contaminated tissues and assessing the results of the microbiological cultures is an effective way of validating the processes of tissue banks. Only when harmonization, based on validated methods, has been achieved, will surgeons be able to fully rely on the methods used and have confidence in the consistent sterility of the tissue grafts. Tissue banks should validate their methods so that all stakeholders can trust the outcomes. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Pérez-Lozano, P; García-Montoya, E; Orriols, A; Miñarro, M; Ticó, J R; Suñé-Negre, J M
2005-10-04
A new HPLC-RP method has been developed and validated for the simultaneous determination of benzocaine, two preservatives (propylparaben (nipasol) and benzyl alcohol) and degradation products of benzocaine in a semisolid pharmaceutical dosage form (benzocaine gel). The method uses a Nucleosil 120 C18 column and gradient elution. The mobile phase consisted of a mixture of methanol and glacial acetic acid (10%, v/v) at different proportion according to a time-schedule programme, pumped at a flow rate of 2.0 ml min(-1). The DAD detector was set at 258 nm. The validation study was carried out fulfilling the ICH guidelines in order to prove that the new analytical method, meets the reliability characteristics, and these characteristics showed the capacity of analytical method to keep, throughout the time, the fundamental criteria for validation: selectivity, linearity, precision, accuracy and sensitivity. The method was applied during the quality control of benzocaine gel in order to quantify the drug (benzocaine), preservatives and degraded products and proved to be suitable for rapid and reliable quality control method.
Alternative methods to determine headwater benefits
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bao, Y.S.; Perlack, R.D.; Sale, M.J.
1997-11-10
In 1992, the Federal Energy Regulatory Commission (FERC) began using a Flow Duration Analysis (FDA) methodology to assess headwater benefits in river basins where use of the Headwater Benefits Energy Gains (HWBEG) model may not result in significant improvements in modeling accuracy. The purpose of this study is to validate the accuracy and appropriateness of the FDA method for determining energy gains in less complex basins. This report presents the results of Oak Ridge National Laboratory`s (ORNL`s) validation of the FDA method. The validation is based on a comparison of energy gains using the FDA method with energy gains calculatedmore » using the MWBEG model. Comparisons of energy gains are made on a daily and monthly basis for a complex river basin (the Alabama River Basin) and a basin that is considered relatively simple hydrologically (the Stanislaus River Basin). In addition to validating the FDA method, ORNL was asked to suggest refinements and improvements to the FDA method. Refinements and improvements to the FDA method were carried out using the James River Basin as a test case.« less
Jiang, Jian; James, Christopher A; Wong, Philip
2016-09-05
A LC-MS/MS method has been developed and validated for the determination of glycine in human cerebrospinal fluid (CSF). The validated method used artificial cerebrospinal fluid as a surrogate matrix for calibration standards. The calibration curve range for the assay was 100-10,000ng/mL and (13)C2, (15)N-glycine was used as an internal standard (IS). Pre-validation experiments were performed to demonstrate parallelism with surrogate matrix and standard addition methods. The mean endogenous glycine concentration in a pooled human CSF determined on three days by using artificial CSF as a surrogate matrix and the method of standard addition was found to be 748±30.6 and 768±18.1ng/mL, respectively. A percentage difference of -2.6% indicated that artificial CSF could be used as a surrogate calibration matrix for the determination of glycine in human CSF. Quality control (QC) samples, except the lower limit of quantitation (LLOQ) QC and low QC samples, were prepared by spiking glycine into aliquots of pooled human CSF sample. The low QC sample was prepared from a separate pooled human CSF sample containing low endogenous glycine concentrations, while the LLOQ QC sample was prepared in artificial CSF. Standard addition was used extensively to evaluate matrix effects during validation. The validated method was used to determine the endogenous glycine concentrations in human CSF samples. Incurred sample reanalysis demonstrated reproducibility of the method. Copyright © 2016 Elsevier B.V. All rights reserved.
Verloock, Leen; Joseph, Wout; Gati, Azeddine; Varsier, Nadège; Flach, Björn; Wiart, Joe; Martens, Luc
2013-06-01
An experimental validation of a low-cost method for extrapolation and estimation of the maximal electromagnetic-field exposure from long-term evolution (LTE) radio base station installations are presented. No knowledge on downlink band occupation or service characteristics is required for the low-cost method. The method is applicable in situ. It only requires a basic spectrum analyser with appropriate field probes without the need of expensive dedicated LTE decoders. The method is validated both in laboratory and in situ, for a single-input single-output antenna LTE system and a 2×2 multiple-input multiple-output system, with low deviations in comparison with signals measured using dedicated LTE decoders.
Validation of biological activity testing procedure of recombinant human interleukin-7.
Lutsenko, T N; Kovalenko, M V; Galkin, O Yu
2017-01-01
Validation procedure for method of monitoring the biological activity of reсombinant human interleukin-7 has been developed and conducted according to the requirements of national and international recommendations. This method is based on the ability of recombinant human interleukin-7 to induce proliferation of T lymphocytes. It has been shown that to control the biological activity of recombinant human interleukin-7 peripheral blood mononuclear cells (PBMCs) derived from blood or cell lines can be used. Validation characteristics that should be determined depend on the method, type of product or object test/measurement and biological test systems used in research. The validation procedure for the method of control of biological activity of recombinant human interleukin-7 in peripheral blood mononuclear cells showed satisfactory results on all parameters tested such as specificity, accuracy, precision and linearity.
NASA Astrophysics Data System (ADS)
Guillevic, P. C.; Nickeson, J. E.; Roman, M. O.; camacho De Coca, F.; Wang, Z.; Schaepman-Strub, G.
2016-12-01
The Global Climate Observing System (GCOS) has specified the need to systematically produce and validate Essential Climate Variables (ECVs). The Committee on Earth Observation Satellites (CEOS) Working Group on Calibration and Validation (WGCV) and in particular its subgroup on Land Product Validation (LPV) is playing a key coordination role leveraging the international expertise required to address actions related to the validation of global land ECVs. The primary objective of the LPV subgroup is to set standards for validation methods and reporting in order to provide traceable and reliable uncertainty estimates for scientists and stakeholders. The Subgroup is comprised of 9 focus areas that encompass 10 land surface variables. The activities of each focus area are coordinated by two international co-leads and currently include leaf area index (LAI) and fraction of absorbed photosynthetically active radiation (FAPAR), vegetation phenology, surface albedo, fire disturbance, snow cover, land cover and land use change, soil moisture, land surface temperature (LST) and emissivity. Recent additions to the focus areas include vegetation indices and biomass. The development of best practice validation protocols is a core activity of CEOS LPV with the objective to standardize the evaluation of land surface products. LPV has identified four validation levels corresponding to increasing spatial and temporal representativeness of reference samples used to perform validation. Best practice validation protocols (1) provide the definition of variables, ancillary information and uncertainty metrics, (2) describe available data sources and methods to establish reference validation datasets with SI traceability, and (3) describe evaluation methods and reporting. An overview on validation best practice components will be presented based on the LAI and LST protocol efforts to date.
ASTM Validates Air Pollution Test Methods
ERIC Educational Resources Information Center
Chemical and Engineering News, 1973
1973-01-01
The American Society for Testing and Materials (ASTM) has validated six basic methods for measuring pollutants in ambient air as the first part of its Project Threshold. Aim of the project is to establish nationwide consistency in measuring pollutants; determining precision, accuracy and reproducibility of 35 standard measuring methods. (BL)
Many PCR-based methods for microbial source tracking (MST) have been developed and validated within individual research laboratories. Inter-laboratory validation of these methods, however, has been minimal, and the effects of protocol standardization regimes have not been thor...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-10
... validation studies. NICEATM and ICCVAM work collaboratively to evaluate new and improved test methods... for nomination of test methods for validation studies, and guidelines for submission of test methods... for human and veterinary vaccine post-licensing potency and safety testing. Plenary and breakout...
A hydrostatic weighing method using total lung capacity and a small tank.
Warner, J G; Yeater, R; Sherwood, L; Weber, K
1986-01-01
The purpose of this study was to establish the validity and reliability of a hydrostatic weighing method using total lung capacity (measuring vital capacity with a respirometer at the time of weighing) the prone position, and a small oblong tank. The validity of the method was established by comparing the TLC prone (tank) method against three hydrostatic weighing methods administered in a pool. The three methods included residual volume seated, TLC seated and TLC prone. Eighty male and female subjects were underwater weighed using each of the four methods. Validity coefficients for per cent body fat between the TLC prone (tank) method and the RV seated (pool), TLC seated (pool) and TLC prone (pool) methods were .98, .99 and .99, respectively. A randomised complete block ANOVA found significant differences between the RV seated (pool) method and each of the three TLC methods with respect to both body density and per cent body fat. The differences were negligible with respect to HW error. Reliability of the TLC prone (tank) method was established by weighing twenty subjects three different times with ten-minute time intervals between testing. Multiple correlations yielded reliability coefficients for body density and per cent body fat values of .99 and .99, respectively. It was concluded that the TLC prone (tank) method is valid, reliable and a favourable method of hydrostatic weighing. PMID:3697596
A hydrostatic weighing method using total lung capacity and a small tank.
Warner, J G; Yeater, R; Sherwood, L; Weber, K
1986-03-01
The purpose of this study was to establish the validity and reliability of a hydrostatic weighing method using total lung capacity (measuring vital capacity with a respirometer at the time of weighing) the prone position, and a small oblong tank. The validity of the method was established by comparing the TLC prone (tank) method against three hydrostatic weighing methods administered in a pool. The three methods included residual volume seated, TLC seated and TLC prone. Eighty male and female subjects were underwater weighed using each of the four methods. Validity coefficients for per cent body fat between the TLC prone (tank) method and the RV seated (pool), TLC seated (pool) and TLC prone (pool) methods were .98, .99 and .99, respectively. A randomised complete block ANOVA found significant differences between the RV seated (pool) method and each of the three TLC methods with respect to both body density and per cent body fat. The differences were negligible with respect to HW error. Reliability of the TLC prone (tank) method was established by weighing twenty subjects three different times with ten-minute time intervals between testing. Multiple correlations yielded reliability coefficients for body density and per cent body fat values of .99 and .99, respectively. It was concluded that the TLC prone (tank) method is valid, reliable and a favourable method of hydrostatic weighing.
History and development of the Schmidt-Hunter meta-analysis methods.
Schmidt, Frank L
2015-09-01
In this article, I provide answers to the questions posed by Will Shadish about the history and development of the Schmidt-Hunter methods of meta-analysis. In the 1970s, I headed a research program on personnel selection at the US Office of Personnel Management (OPM). After our research showed that validity studies have low statistical power, OPM felt a need for a better way to demonstrate test validity, especially in light of court cases challenging selection methods. In response, we created our method of meta-analysis (initially called validity generalization). Results showed that most of the variability of validity estimates from study to study was because of sampling error and other research artifacts such as variations in range restriction and measurement error. Corrections for these artifacts in our research and in replications by others showed that the predictive validity of most tests was high and generalizable. This conclusion challenged long-standing beliefs and so provoked resistance, which over time was overcome. The 1982 book that we published extending these methods to research areas beyond personnel selection was positively received and was followed by expanded books in 1990, 2004, and 2014. Today, these methods are being applied in a wide variety of areas. Copyright © 2015 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Ranaie, Mehrdad; Soffianian, Alireza; Pourmanafi, Saeid; Mirghaffari, Noorollah; Tarkesh, Mostafa
2018-03-01
In recent decade, analyzing the remotely sensed imagery is considered as one of the most common and widely used procedures in the environmental studies. In this case, supervised image classification techniques play a central role. Hence, taking a high resolution Worldview-3 over a mixed urbanized landscape in Iran, three less applied image classification methods including Bagged CART, Stochastic gradient boosting model and Neural network with feature extraction were tested and compared with two prevalent methods: random forest and support vector machine with linear kernel. To do so, each method was run ten time and three validation techniques was used to estimate the accuracy statistics consist of cross validation, independent validation and validation with total of train data. Moreover, using ANOVA and Tukey test, statistical difference significance between the classification methods was significantly surveyed. In general, the results showed that random forest with marginal difference compared to Bagged CART and stochastic gradient boosting model is the best performing method whilst based on independent validation there was no significant difference between the performances of classification methods. It should be finally noted that neural network with feature extraction and linear support vector machine had better processing speed than other.
Machado, J C; Lange, A D; Todeschini, V; Volpato, N M
2014-02-01
A dissolution method to analyze atorvastatin tablets using in vivo data for RP and test pilot (PB) was developed and validated. The appropriate conditions were determined after solubility tests using different media, and sink conditions were established. The conditions used were equipment paddle at 50 rpm and 900 mL of potassium phosphate buffer pH 6.0 as dissolution medium. In vivo release profiles were obtained from the bioequivalence study of RP and the generic candidate PB. The fraction of dose absorbed was calculated using the Loo-Riegelman method. It was necessary to use a scale factor of time similar to 6.0, to associate the values of absorbed fraction and dissolved fraction, obtaining an in vivo-in vitro correlation level A. The dissolution method to quantify the amount of drug dissolved was validated using high-performance liquid chromatography and ultraviolet spectrophotometry, and validated according to the USP protocol. The discriminative power of dissolution conditions was assessed using two different pilot batches of atorvastatin tablets (PA and PB) and RP. The dissolution test was validated and may be used as a discriminating method in quality control and in the development of the new formulations.
Analysis of Phosphonic Acids: Validation of Semi-Volatile Analysis by HPLC-MS/MS by EPA Method MS999
DOE Office of Scientific and Technical Information (OSTI.GOV)
Owens, J; Vu, A; Koester, C
The Environmental Protection Agency's (EPA) Region 5 Chicago Regional Laboratory (CRL) developed a method titled Analysis of Diisopropyl Methylphosphonate, Ethyl Hydrogen Dimethylamidophosphate, Isopropyl Methylphosphonic Acid, Methylphosphonic Acid, and Pinacolyl Methylphosphonic Acid in Water by Multiple Reaction Monitoring Liquid Chromatography/Tandem Mass Spectrometry: EPA Version MS999. This draft standard operating procedure (SOP) was distributed to multiple EPA laboratories and to Lawrence Livermore National Laboratory, which was tasked to serve as a reference laboratory for EPA's Environmental Reference Laboratory Network (ERLN) and to develop and validate analytical procedures. The primary objective of this study was to validate and verify the analytical procedures describedmore » in EPA Method MS999 for analysis of the listed phosphonic acids and surrogates in aqueous samples. The gathered data from this validation study will be used to: (1) demonstrate analytical method performance; (2) generate quality control acceptance criteria; and (3) revise the SOP to provide a validated method that would be available for use during a homeland security event. The data contained in this report will be compiled, by EPA CRL, with data generated by other EPA Regional laboratories so that performance metrics of EPA Method MS999 can be determined.« less
Testing and Validation of Computational Methods for Mass Spectrometry.
Gatto, Laurent; Hansen, Kasper D; Hoopmann, Michael R; Hermjakob, Henning; Kohlbacher, Oliver; Beyer, Andreas
2016-03-04
High-throughput methods based on mass spectrometry (proteomics, metabolomics, lipidomics, etc.) produce a wealth of data that cannot be analyzed without computational methods. The impact of the choice of method on the overall result of a biological study is often underappreciated, but different methods can result in very different biological findings. It is thus essential to evaluate and compare the correctness and relative performance of computational methods. The volume of the data as well as the complexity of the algorithms render unbiased comparisons challenging. This paper discusses some problems and challenges in testing and validation of computational methods. We discuss the different types of data (simulated and experimental validation data) as well as different metrics to compare methods. We also introduce a new public repository for mass spectrometric reference data sets ( http://compms.org/RefData ) that contains a collection of publicly available data sets for performance evaluation for a wide range of different methods.
Validity and reliability of a method for assessment of cervical vertebral maturation.
Zhao, Xiao-Guang; Lin, Jiuxiang; Jiang, Jiu-Hui; Wang, Qingzhu; Ng, Sut Hong
2012-03-01
To evaluate the validity and reliability of the cervical vertebral maturation (CVM) method with a longitudinal sample. Eighty-six cephalograms from 18 subjects (5 males and 13 females) were selected from the longitudinal database. Total mandibular length was measured on each film; an increased rate served as the gold standard in examination of the validity of the CVM method. Eleven orthodontists, after receiving intensive training in the CVM method, evaluated all films twice. Kendall's W and the weighted kappa statistic were employed. Kendall's W values were higher than 0.8 at both times, indicating strong interobserver reproducibility, but interobserver agreement was documented twice at less than 50%. A wide range of intraobserver agreement was noted (40.7%-79.1%), and substantial intraobserver reproducibility was proved by kappa values (0.53-0.86). With regard to validity, moderate agreement was reported between the gold standard and observer staging at the initial time (kappa values 0.44-0.61). However, agreement seemed to be unacceptable for clinical use, especially in cervical stage 3 (26.8%). Even though the validity and reliability of the CVM method proved statistically acceptable, we suggest that many other growth indicators should be taken into consideration in evaluating adolescent skeletal maturation.
Garcia Hejl, Carine; Ramirez, Jose Manuel; Vest, Philippe; Chianea, Denis; Renard, Christophe
2014-09-01
Laboratories working towards accreditation by the International Standards Organization (ISO) 15189 standard are required to demonstrate the validity of their analytical methods. The different guidelines set by various accreditation organizations make it difficult to provide objective evidence that an in-house method is fit for the intended purpose. Besides, the required performance characteristics tests and acceptance criteria are not always detailed. The laboratory must choose the most suitable validation protocol and set the acceptance criteria. Therefore, we propose a validation protocol to evaluate the performance of an in-house method. As an example, we validated the process for the detection and quantification of lead in whole blood by electrothermal absorption spectrometry. The fundamental parameters tested were, selectivity, calibration model, precision, accuracy (and uncertainty of measurement), contamination, stability of the sample, reference interval, and analytical interference. We have developed a protocol that has been applied successfully to quantify lead in whole blood by electrothermal atomic absorption spectrometry (ETAAS). In particular, our method is selective, linear, accurate, and precise, making it suitable for use in routine diagnostics.
Semi-automating the manual literature search for systematic reviews increases efficiency.
Chapman, Andrea L; Morgan, Laura C; Gartlehner, Gerald
2010-03-01
To minimise retrieval bias, manual literature searches are a key part of the search process of any systematic review. Considering the need to have accurate information, valid results of the manual literature search are essential to ensure scientific standards; likewise efficient approaches that minimise the amount of personnel time required to conduct a manual literature search are of great interest. The objective of this project was to determine the validity and efficiency of a new manual search method that utilises the scopus database. We used the traditional manual search approach as the gold standard to determine the validity and efficiency of the proposed scopus method. Outcome measures included completeness of article detection and personnel time involved. Using both methods independently, we compared the results based on accuracy of the results, validity and time spent conducting the search, efficiency. Regarding accuracy, the scopus method identified the same studies as the traditional approach indicating its validity. In terms of efficiency, using scopus led to a time saving of 62.5% compared with the traditional approach (3 h versus 8 h). The scopus method can significantly improve the efficiency of manual searches and thus of systematic reviews.
Mirza, Tahseen; Liu, Qian Julie; Vivilecchia, Richard; Joshi, Yatindra
2009-03-01
There has been a growing interest during the past decade in the use of fiber optics dissolution testing. Use of this novel technology is mainly confined to research and development laboratories. It has not yet emerged as a tool for end product release testing despite its ability to generate in situ results and efficiency improvement. One potential reason may be the lack of clear validation guidelines that can be applied for the assessment of suitability of fiber optics. This article describes a comprehensive validation scheme and development of a reliable, robust, reproducible and cost-effective dissolution test using fiber optics technology. The test was successfully applied for characterizing the dissolution behavior of a 40-mg immediate-release tablet dosage form that is under development at Novartis Pharmaceuticals, East Hanover, New Jersey. The method was validated for the following parameters: linearity, precision, accuracy, specificity, and robustness. In particular, robustness was evaluated in terms of probe sampling depth and probe orientation. The in situ fiber optic method was found to be comparable to the existing manual sampling dissolution method. Finally, the fiber optic dissolution test was successfully performed by different operators on different days, to further enhance the validity of the method. The results demonstrate that the fiber optics technology can be successfully validated for end product dissolution/release testing. (c) 2008 Wiley-Liss, Inc. and the American Pharmacists Association
Proposal of a method for the evaluation of inaccuracy of home sphygmomanometers.
Akpolat, Tekin
2009-10-01
There is no formal protocol for evaluating the individual accuracy of home sphygmomanometers. The aims of this study were to propose a method for achieving accuracy in automated home sphygmomanometers and to test the applicability of the defined method. The purposes of this method were to avoid major inaccuracies and to estimate the optimal circumstance for individual accuracy. The method has three stages and sequential measurement of blood pressure is used. The tested devices were categorized into four groups: accurate, acceptable, inaccurate and very inaccurate (major inaccuracy). The defined method takes approximately 10 min (excluding relaxation time) and was tested on three different occasions. The application of the method has shown that inaccuracy is a common problem among non-tested devices, that validated devices are superior to those that are non-validated or whose validation status is unknown, that major inaccuracy is common, especially in non-tested devices and that validation does not guarantee individual accuracy. A protocol addressing the accuracy of a particular sphygmomanometer in an individual patient is required, and a practical method has been suggested to achieve this. This method can be modified, but the main idea and approach should be preserved unless a better method is proposed. The purchase of validated devices and evaluation of accuracy for the purchased device in an individual patient will improve the monitoring of self-measurement of blood pressure at home. This study addresses device inaccuracy, but errors related to the patient, observer or blood pressure measurement technique should not be underestimated, and strict adherence to the manufacturer's instructions is essential.
Correcting for Optimistic Prediction in Small Data Sets
Smith, Gordon C. S.; Seaman, Shaun R.; Wood, Angela M.; Royston, Patrick; White, Ian R.
2014-01-01
The C statistic is a commonly reported measure of screening test performance. Optimistic estimation of the C statistic is a frequent problem because of overfitting of statistical models in small data sets, and methods exist to correct for this issue. However, many studies do not use such methods, and those that do correct for optimism use diverse methods, some of which are known to be biased. We used clinical data sets (United Kingdom Down syndrome screening data from Glasgow (1991–2003), Edinburgh (1999–2003), and Cambridge (1990–2006), as well as Scottish national pregnancy discharge data (2004–2007)) to evaluate different approaches to adjustment for optimism. We found that sample splitting, cross-validation without replication, and leave-1-out cross-validation produced optimism-adjusted estimates of the C statistic that were biased and/or associated with greater absolute error than other available methods. Cross-validation with replication, bootstrapping, and a new method (leave-pair-out cross-validation) all generated unbiased optimism-adjusted estimates of the C statistic and had similar absolute errors in the clinical data set. Larger simulation studies confirmed that all 3 methods performed similarly with 10 or more events per variable, or when the C statistic was 0.9 or greater. However, with lower events per variable or lower C statistics, bootstrapping tended to be optimistic but with lower absolute and mean squared errors than both methods of cross-validation. PMID:24966219
Hubert, C; Houari, S; Rozet, E; Lebrun, P; Hubert, Ph
2015-05-22
When using an analytical method, defining an analytical target profile (ATP) focused on quantitative performance represents a key input, and this will drive the method development process. In this context, two case studies were selected in order to demonstrate the potential of a quality-by-design (QbD) strategy when applied to two specific phases of the method lifecycle: the pre-validation study and the validation step. The first case study focused on the improvement of a liquid chromatography (LC) coupled to mass spectrometry (MS) stability-indicating method by the means of the QbD concept. The design of experiments (DoE) conducted during the optimization step (i.e. determination of the qualitative design space (DS)) was performed a posteriori. Additional experiments were performed in order to simultaneously conduct the pre-validation study to assist in defining the DoE to be conducted during the formal validation step. This predicted protocol was compared to the one used during the formal validation. A second case study based on the LC/MS-MS determination of glucosamine and galactosamine in human plasma was considered in order to illustrate an innovative strategy allowing the QbD methodology to be incorporated during the validation phase. An operational space, defined by the qualitative DS, was considered during the validation process rather than a specific set of working conditions as conventionally performed. Results of all the validation parameters conventionally studied were compared to those obtained with this innovative approach for glucosamine and galactosamine. Using this strategy, qualitative and quantitative information were obtained. Consequently, an analyst using this approach would be able to select with great confidence several working conditions within the operational space rather than a given condition for the routine use of the method. This innovative strategy combines both a learning process and a thorough assessment of the risk involved. Copyright © 2015 Elsevier B.V. All rights reserved.
Real-Time PCR Method for Detection of Salmonella spp. in Environmental Samples.
Kasturi, Kuppuswamy N; Drgon, Tomas
2017-07-15
The methods currently used for detecting Salmonella in environmental samples require 2 days to produce results and have limited sensitivity. Here, we describe the development and validation of a real-time PCR Salmonella screening method that produces results in 18 to 24 h. Primers and probes specific to the gene invA , group D, and Salmonella enterica serovar Enteritidis organisms were designed and evaluated for inclusivity and exclusivity using a panel of 329 Salmonella isolates representing 126 serovars and 22 non- Salmonella organisms. The invA - and group D-specific sets identified all the isolates accurately. The PCR method had 100% inclusivity and detected 1 to 2 copies of Salmonella DNA per reaction. Primers specific for Salmonella -differentiating fragment 1 (Sdf-1) in conjunction with the group D set had 100% inclusivity for 32 S Enteritidis isolates and 100% exclusivity for the 297 non-Enteritidis Salmonella isolates. Single-laboratory validation performed on 1,741 environmental samples demonstrated that the PCR method detected 55% more positives than the V itek i mmuno d iagnostic a ssay s ystem (VIDAS) method. The PCR results correlated well with the culture results, and the method did not report any false-negative results. The receiver operating characteristic (ROC) analysis documented excellent agreement between the results from the culture and PCR methods (area under the curve, 0.90; 95% confidence interval of 0.76 to 1.0) confirming the validity of the PCR method. IMPORTANCE This validated PCR method detects 55% more positives for Salmonella in half the time required for the reference method, VIDAS. The validated PCR method will help to strengthen public health efforts through rapid screening of Salmonella spp. in environmental samples.
Real-Time PCR Method for Detection of Salmonella spp. in Environmental Samples
Drgon, Tomas
2017-01-01
ABSTRACT The methods currently used for detecting Salmonella in environmental samples require 2 days to produce results and have limited sensitivity. Here, we describe the development and validation of a real-time PCR Salmonella screening method that produces results in 18 to 24 h. Primers and probes specific to the gene invA, group D, and Salmonella enterica serovar Enteritidis organisms were designed and evaluated for inclusivity and exclusivity using a panel of 329 Salmonella isolates representing 126 serovars and 22 non-Salmonella organisms. The invA- and group D-specific sets identified all the isolates accurately. The PCR method had 100% inclusivity and detected 1 to 2 copies of Salmonella DNA per reaction. Primers specific for Salmonella-differentiating fragment 1 (Sdf-1) in conjunction with the group D set had 100% inclusivity for 32 S. Enteritidis isolates and 100% exclusivity for the 297 non-Enteritidis Salmonella isolates. Single-laboratory validation performed on 1,741 environmental samples demonstrated that the PCR method detected 55% more positives than the Vitek immunodiagnostic assay system (VIDAS) method. The PCR results correlated well with the culture results, and the method did not report any false-negative results. The receiver operating characteristic (ROC) analysis documented excellent agreement between the results from the culture and PCR methods (area under the curve, 0.90; 95% confidence interval of 0.76 to 1.0) confirming the validity of the PCR method. IMPORTANCE This validated PCR method detects 55% more positives for Salmonella in half the time required for the reference method, VIDAS. The validated PCR method will help to strengthen public health efforts through rapid screening of Salmonella spp. in environmental samples. PMID:28500041
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-18
... 29-30, 2011, to evaluate the validation status of the LUMI-CELL[supreg] (BG1Luc ER TA) test method...: http://iccvam.niehs.nih.gov/docs/endo_docs/EDPRPRept2011.pdf or by contacting NICEATM (see ADDRESSES). The report contains (1) the Panel's evaluation of the validation status of the test method and (2) the...
ERIC Educational Resources Information Center
Thomas, Michael L.; Lanyon, Richard I.; Millsap, Roger E.
2009-01-01
The use of criterion group validation is hindered by the difficulty of classifying individuals on latent constructs. Latent class analysis (LCA) is a method that can be used for determining the validity of scales meant to assess latent constructs without such a priori classifications. The authors used this method to examine the ability of the L…
Moye, Jennifer; Azar, Annin R.; Karel, Michele J.; Gurrera, Ronald J.
2016-01-01
Does instrument based evaluation of consent capacity increase the precision and validity of competency assessment or does ostensible precision provide a false sense of confidence without in fact improving validity? In this paper we critically examine the evidence for construct validity of three instruments for measuring four functional abilities important in consent capacity: understanding, appreciation, reasoning, and expressing a choice. Instrument based assessment of these abilities is compared through investigation of a multi-trait multi-method matrix in 88 older adults with mild to moderate dementia. Results find variable support for validity. There appears to be strong evidence for good hetero-method validity for the measurement of understanding, mixed evidence for validity in the measurement of reasoning, and strong evidence for poor hetero-method validity for the concepts of appreciation and expressing a choice, although the latter is likely due to extreme range restrictions. The development of empirically based tools for use in capacity evaluation should ultimately enhance the reliability and validity of assessment, yet clearly more research is needed to define and measure the constructs of decisional capacity. We would also emphasize that instrument based assessment of capacity is only one part of a comprehensive evaluation of competency which includes consideration of diagnosis, psychiatric and/or cognitive symptomatology, risk involved in the situation, and individual and cultural differences. PMID:27330455
Practical Aspects of Designing and Conducting Validation Studies Involving Multi-study Trials.
Coecke, Sandra; Bernasconi, Camilla; Bowe, Gerard; Bostroem, Ann-Charlotte; Burton, Julien; Cole, Thomas; Fortaner, Salvador; Gouliarmou, Varvara; Gray, Andrew; Griesinger, Claudius; Louhimies, Susanna; Gyves, Emilio Mendoza-de; Joossens, Elisabeth; Prinz, Maurits-Jan; Milcamps, Anne; Parissis, Nicholaos; Wilk-Zasadna, Iwona; Barroso, João; Desprez, Bertrand; Langezaal, Ingrid; Liska, Roman; Morath, Siegfried; Reina, Vittorio; Zorzoli, Chiara; Zuang, Valérie
This chapter focuses on practical aspects of conducting prospective in vitro validation studies, and in particular, by laboratories that are members of the European Union Network of Laboratories for the Validation of Alternative Methods (EU-NETVAL) that is coordinated by the EU Reference Laboratory for Alternatives to Animal Testing (EURL ECVAM). Prospective validation studies involving EU-NETVAL, comprising a multi-study trial involving several laboratories or "test facilities", typically consist of two main steps: (1) the design of the validation study by EURL ECVAM and (2) the execution of the multi-study trial by a number of qualified laboratories within EU-NETVAL, coordinated and supported by EURL ECVAM. The approach adopted in the conduct of these validation studies adheres to the principles described in the OECD Guidance Document on the Validation and International Acceptance of new or updated test methods for Hazard Assessment No. 34 (OECD 2005). The context and scope of conducting prospective in vitro validation studies is dealt with in Chap. 4 . Here we focus mainly on the processes followed to carry out a prospective validation of in vitro methods involving different laboratories with the ultimate aim of generating a dataset that can support a decision in relation to the possible development of an international test guideline (e.g. by the OECD) or the establishment of performance standards.
Mlangeni, Angstone Thembachako; Vecchi, Valeria; Norton, Gareth J; Raab, Andrea; Krupp, Eva M; Feldmann, Joerg
2018-10-15
A commercial arsenic field kit designed to measure inorganic arsenic (iAs) in water was modified into a field deployable method (FDM) to measure iAs in rice. While the method has been validated to give precise and accurate results in the laboratory, its on-site field performance has not been evaluated. This study was designed to test the method on-site in Malawi in order to evaluate its accuracy and precision in determination of iAs on-site by comparing with a validated reference method and giving original data on inorganic arsenic in Malawian rice and rice-based products. The method was validated by using the established laboratory-based HPLC-ICPMS. Statistical tests indicated there were no significant differences between on-site and laboratory iAs measurements determined using the FDM (p = 0.263, ά = 0.05) and between on-site measurements and measurements determined using HPLC-ICP-MS (p = 0.299, ά = 0.05). This method allows quick (within 1 h) and efficient screening of rice containing iAs concentrations on-site. Copyright © 2018 Elsevier Ltd. All rights reserved.
Rebouças, Camila Tavares; Kogawa, Ana Carolina; Salgado, Hérida Regina Nunes
2018-05-18
Background: A green analytical chemistry method was developed for quantification of enrofloxacin in tablets. The drug, a second-generation fluoroquinolone, was first introduced in veterinary medicine for the treatment of various bacterial species. Objective: This study proposed to develop, validate, and apply a reliable, low-cost, fast, and simple IR spectroscopy method for quantitative routine determination of enrofloxacin in tablets. Methods: The method was completely validated according to the International Conference on Harmonisation guidelines, showing accuracy, precision, selectivity, robustness, and linearity. Results: It was linear over the concentration range of 1.0-3.0 mg with correlation coefficients >0.9999 and LOD and LOQ of 0.12 and 0.36 mg, respectively. Conclusions: Now that this IR method has met performance qualifications, it can be adopted and applied for the analysis of enrofloxacin tablets for production process control. The validated method can also be utilized to quantify enrofloxacin in tablets and thus is an environmentally friendly alternative for the routine analysis of enrofloxacin in quality control. Highlights: A new green method for the quantitative analysis of enrofloxacin by Fourier-Transform Infrared spectroscopy was validated. It is a fast, clean and low-cost alternative for the evaluation of enrofloxacin tablets.
Cross-validation of the Beunen-Malina method to predict adult height.
Beunen, Gaston P; Malina, Robert M; Freitas, Duarte I; Maia, José A; Claessens, Albrecht L; Gouveia, Elvio R; Lefevre, Johan
2010-08-01
The purpose of this study was to cross-validate the Beunen-Malina method for non-invasive prediction of adult height. Three hundred and eight boys aged 13, 14, 15 and 16 years from the Madeira Growth Study were observed at annual intervals in 1996, 1997 and 1998 and re-measured 7-8 years later. Height, sitting height and the triceps and subscapular skinfolds were measured; skeletal age was assessed using the Tanner-Whitehouse 2 method. Adult height was measured and predicted using the Beunen-Malina method. Maturity groups were classified using relative skeletal age (skeletal age minus chronological age). Pearson correlations, mean differences and standard errors of estimate (SEE) were calculated. Age-specific correlations between predicted and measured adult height vary between 0.70 and 0.85, while age-specific SEE varies between 3.3 and 4.7 cm. The correlations and SEE are similar to those obtained in the development of the original Beunen-Malina method. The Beunen-Malina method is a valid method to predict adult height in adolescent boys and can be used in European populations or populations from European ancestry. Percentage of predicted adult height is a non-invasive valid method to assess biological maturity.
Chang, Yuanhan; Tambe, Abhijit Anil; Maeda, Yoshinobu; Wada, Masahiro; Gonda, Tomoya
2018-03-08
A literature review of finite element analysis (FEA) studies of dental implants with their model validation process was performed to establish the criteria for evaluating validation methods with respect to their similarity to biological behavior. An electronic literature search of PubMed was conducted up to January 2017 using the Medical Subject Headings "dental implants" and "finite element analysis." After accessing the full texts, the context of each article was searched using the words "valid" and "validation" and articles in which these words appeared were read to determine whether they met the inclusion criteria for the review. Of 601 articles published from 1997 to 2016, 48 that met the eligibility criteria were selected. The articles were categorized according to their validation method as follows: in vivo experiments in humans (n = 1) and other animals (n = 3), model experiments (n = 32), others' clinical data and past literature (n = 9), and other software (n = 2). Validation techniques with a high level of sufficiency and efficiency are still rare in FEA studies of dental implants. High-level validation, especially using in vivo experiments tied to an accurate finite element method, needs to become an established part of FEA studies. The recognition of a validation process should be considered when judging the practicality of an FEA study.
Development of a refractive error quality of life scale for Thai adults (the REQ-Thai).
Sukhawarn, Roongthip; Wiratchai, Nonglak; Tatsanavivat, Pyatat; Pitiyanuwat, Somwung; Kanato, Manop; Srivannaboon, Sabong; Guyatt, Gordon H
2011-08-01
To develop a scale for measuring refractive error quality of life (QOL) for Thai adults. The full survey comprised 424 respondents from 5 medical centers in Bangkok and from 3 medical centers in Chiangmai, Songkla and KhonKaen provinces. Participants were emmetropes and persons with refractive correction with visual acuity of 20/30 or better An item reduction process was employed by combining 3 methods-expert opinion, impact method and item-total correlation methods. The classical reliability testing and the validity testing including convergent, discriminative and construct validity was performed. The developed questionnaire comprised 87 items in 6 dimensions: 1) quality of vision, 2) visual function, 3) social function, 4) psychological function, 5) symptoms and 6) refractive correction problems. It is the 5-level Likert scale type. The Cronbach's Alpha coefficients of its dimensions ranged from 0.756 to 0. 979. All validity testing were shown to be valid. The construct validity was validated by the confirmatory factor analysis. A short version questionnaire comprised 48 items with good reliability and validity was also developed. This is the first validated instrument for measuring refractive error quality of life for Thai adults that was developed with strong research methodology and large sample size.
Janssen, Ellen M; Marshall, Deborah A; Hauber, A Brett; Bridges, John F P
2017-12-01
The recent endorsement of discrete-choice experiments (DCEs) and other stated-preference methods by regulatory and health technology assessment (HTA) agencies has placed a greater focus on demonstrating the validity and reliability of preference results. Areas covered: We present a practical overview of tests of validity and reliability that have been applied in the health DCE literature and explore other study qualities of DCEs. From the published literature, we identify a variety of methods to assess the validity and reliability of DCEs. We conceptualize these methods to create a conceptual model with four domains: measurement validity, measurement reliability, choice validity, and choice reliability. Each domain consists of three categories that can be assessed using one to four procedures (for a total of 24 tests). We present how these tests have been applied in the literature and direct readers to applications of these tests in the health DCE literature. Based on a stakeholder engagement exercise, we consider the importance of study characteristics beyond traditional concepts of validity and reliability. Expert commentary: We discuss study design considerations to assess the validity and reliability of a DCE, consider limitations to the current application of tests, and discuss future work to consider the quality of DCEs in healthcare.
Uno, Yoshifumi; Kojima, Hajime; Omori, Takashi; Corvi, Raffaella; Honma, Masamistu; Schechtman, Leonard M; Tice, Raymond R; Beevers, Carol; De Boeck, Marlies; Burlinson, Brian; Hobbs, Cheryl A; Kitamoto, Sachiko; Kraynak, Andrew R; McNamee, James; Nakagawa, Yuzuki; Pant, Kamala; Plappert-Helbig, Ulla; Priestley, Catherine; Takasawa, Hironao; Wada, Kunio; Wirnitzer, Uta; Asano, Norihide; Escobar, Patricia A; Lovell, David; Morita, Takeshi; Nakajima, Madoka; Ohno, Yasuo; Hayashi, Makoto
2015-07-01
The in vivo rodent alkaline comet assay (comet assay) is used internationally to investigate the in vivo genotoxic potential of test chemicals. This assay, however, has not previously been formally validated. The Japanese Center for the Validation of Alternative Methods (JaCVAM), with the cooperation of the U.S. NTP Interagency Center for the Evaluation of Alternative Toxicological Methods (NICEATM)/the Interagency Coordinating Committee on the Validation of Alternative Methods (ICCVAM), the European Centre for the Validation of Alternative Methods (ECVAM), and the Japanese Environmental Mutagen Society/Mammalian Mutagenesis Study Group (JEMS/MMS), organized an international validation study to evaluate the reliability and relevance of the assay for identifying genotoxic carcinogens, using liver and stomach as target organs. The ultimate goal of this exercise was to establish an Organisation for Economic Co-operation and Development (OECD) test guideline. The study protocol was optimized in the pre-validation studies, and then the definitive (4th phase) validation study was conducted in two steps. In the 1st step, assay reproducibility was confirmed among laboratories using four coded reference chemicals and the positive control ethyl methanesulfonate. In the 2nd step, the predictive capability was investigated using 40 coded chemicals with known genotoxic and carcinogenic activity (i.e., genotoxic carcinogens, genotoxic non-carcinogens, non-genotoxic carcinogens, and non-genotoxic non-carcinogens). Based on the results obtained, the in vivo comet assay is concluded to be highly capable of identifying genotoxic chemicals and therefore can serve as a reliable predictor of rodent carcinogenicity. Copyright © 2015 Elsevier B.V. All rights reserved.
Validation of a spectrophotometric assay method for bisoprolol using picric acid.
Panainte, Alina-Diana; Bibire, Nela; Tântaru, Gladiola; Apostu, M; Vieriu, Mădălina
2013-01-01
Bisoprolol is a drug belonging to beta blockers drugs used primarily for the treatment of cardiovascular diseases. A spectrophotometric method for quantitative determination of bisoprolol was developed based on the formation of a complex combination between bisoprolol and picric acid. The complex combination of bisoprolol and picric acid has a maximum absorbance peak at 420 nm. Optimum working conditions were established and the method was validated. The method presented a good linearity in the concentration range 5-120 microg/ml (regression coefficient r2 = 0.9992). The RSD for the precision of the method was 1.74 and for the intermediate precision 1.43, and recovery values ranged between 98.25-101.48%. The proposed and validated spectrophotometric method for the determination of bisoprolol is simple and cost effective.
The construct validity of session RPE during an intensive camp in young male Karate athletes.
Padulo, Johnny; Chaabène, Helmi; Tabben, Montassar; Haddad, Monoem; Gevat, Cecilia; Vando, Stefano; Maurino, Lucio; Chaouachi, Anis; Chamari, Karim
2014-04-01
the aim of this study was to assess the validity of the session rating of perceived exertion (RPE) method and two objective HR-based methods for quantifying karate's training load (TL) in young Karatekas. eleven athletes (age 12.50±1.84 years) participated in this study. The training period/camp was performed on 5 consecutive days with two training session (s) per-day (d). Construct validity of RPE method in young Karate athletes, was studied by correlation analysis between RPE session's training load and both Edwards and Banister's training impulse score' method. significant relationship was found between inter-day (n-11 × d-5 × s-2 = 110) sessions RPE and Edwards (r values from 0.84 to 0.92 p < 0.001) and Banister's (r values from 0.84 to 0.97 p < 0.001), respectively. this study showed that session-RPE can be considered a valid method for quantifying karate's training load in young karate athletes.
NASA Technical Reports Server (NTRS)
Ray, Ronald J.
1994-01-01
New flight test maneuvers and analysis techniques for evaluating the dynamic response of in-flight thrust models during throttle transients have been developed and validated. The approach is based on the aircraft and engine performance relationship between thrust and drag. Two flight test maneuvers, a throttle step and a throttle frequency sweep, were developed and used in the study. Graphical analysis techniques, including a frequency domain analysis method, were also developed and evaluated. They provide quantitative and qualitative results. Four thrust calculation methods were used to demonstrate and validate the test technique. Flight test applications on two high-performance aircraft confirmed the test methods as valid and accurate. These maneuvers and analysis techniques were easy to implement and use. Flight test results indicate the analysis techniques can identify the combined effects of model error and instrumentation response limitations on the calculated thrust value. The methods developed in this report provide an accurate approach for evaluating, validating, or comparing thrust calculation methods for dynamic flight applications.
Liebers, Falk; Brandstädt, Felix; Schust, Marianne; Serafin, Patrick; Schäfer, Andreas; Gebhardt, Hansjürgen; Hartmann, Bernd; Steinberg, Ulf
2017-01-01
Introduction The impact of work-related musculoskeletal disorders is considerable. The assessment of work tasks with physical workloads is crucial to estimate the work-related health risks of exposed employees. Three key indicator methods are available for risk assessment regarding manual lifting, holding and carrying of loads; manual pulling and pushing of loads; and manual handling operations. Three further KIMs for risk assessment regarding whole-body forces, awkward body postures and body movement have been developed de novo. In addition, the development of a newly drafted combined method for mixed exposures is planned. All methods will be validated regarding face validity, reliability, convergent validity, criterion validity and further aspects of utility under practical conditions. Methods and analysis As part of the joint project MEGAPHYS (multilevel risk assessment of physical workloads), a mixed-methods study is being designed for the validation of KIMs and conducted in companies of different sizes and branches in Germany. Workplaces are documented and analysed by observations, applying KIMs, interviews and assessment of environmental conditions. Furthermore, a survey among the employees at the respective workplaces takes place with standardised questionnaires, interviews and physical examinations. It is intended to include 1200 employees at 120 different workplaces. For analysis of the quality criteria, recommendations of the COSMIN checklist (COnsensus-based Standards for the selection of health Measurement INstruments) will be taken into account. Ethics and dissemination The study was planned and conducted in accordance with the German Medical Professional Code and the Declaration of Helsinki as well as the German Federal Data Protection Act. The design of the study was approved by ethics committees. We intend to publish the validated KIMs in 2018. Results will be published in peer-reviewed journals, presented at international meetings and disseminated to actual users for practical application. PMID:28827239
Sánchez-Margallo, Juan A; Sánchez-Margallo, Francisco M; Oropesa, Ignacio; Enciso, Silvia; Gómez, Enrique J
2017-02-01
The aim of this study is to present the construct and concurrent validity of a motion-tracking method of laparoscopic instruments based on an optical pose tracker and determine its feasibility as an objective assessment tool of psychomotor skills during laparoscopic suturing. A group of novice ([Formula: see text] laparoscopic procedures), intermediate (11-100 laparoscopic procedures) and experienced ([Formula: see text] laparoscopic procedures) surgeons performed three intracorporeal sutures on an ex vivo porcine stomach. Motion analysis metrics were recorded using the proposed tracking method, which employs an optical pose tracker to determine the laparoscopic instruments' position. Construct validation was measured for all 10 metrics across the three groups and between pairs of groups. Concurrent validation was measured against a previously validated suturing checklist. Checklists were completed by two independent surgeons over blinded video recordings of the task. Eighteen novices, 15 intermediates and 11 experienced surgeons took part in this study. Execution time and path length travelled by the laparoscopic dissector presented construct validity. Experienced surgeons required significantly less time ([Formula: see text]), travelled less distance using both laparoscopic instruments ([Formula: see text]) and made more efficient use of the work space ([Formula: see text]) compared with novice and intermediate surgeons. Concurrent validation showed strong correlation between both the execution time and path length and the checklist score ([Formula: see text] and [Formula: see text], [Formula: see text]). The suturing performance was successfully assessed by the motion analysis method. Construct and concurrent validity of the motion-based assessment method has been demonstrated for the execution time and path length metrics. This study demonstrates the efficacy of the presented method for objective evaluation of psychomotor skills in laparoscopic suturing. However, this method does not take into account the quality of the suture. Thus, future works will focus on developing new methods combining motion analysis and qualitative outcome evaluation to provide a complete performance assessment to trainees.
Comparing Thermal Process Validation Methods for Salmonella Inactivation on Almond Kernels.
Jeong, Sanghyup; Marks, Bradley P; James, Michael K
2017-01-01
Ongoing regulatory changes are increasing the need for reliable process validation methods for pathogen reduction processes involving low-moisture products; however, the reliability of various validation methods has not been evaluated. Therefore, the objective was to quantify accuracy and repeatability of four validation methods (two biologically based and two based on time-temperature models) for thermal pasteurization of almonds. Almond kernels were inoculated with Salmonella Enteritidis phage type 30 or Enterococcus faecium (NRRL B-2354) at ~10 8 CFU/g, equilibrated to 0.24, 0.45, 0.58, or 0.78 water activity (a w ), and then heated in a pilot-scale, moist-air impingement oven (dry bulb 121, 149, or 177°C; dew point <33.0, 69.4, 81.6, or 90.6°C; v air = 2.7 m/s) to a target lethality of ~4 log. Almond surface temperatures were measured in two ways, and those temperatures were used to calculate Salmonella inactivation using a traditional (D, z) model and a modified model accounting for process humidity. Among the process validation methods, both methods based on time-temperature models had better repeatability, with replication errors approximately half those of the surrogate ( E. faecium ). Additionally, the modified model yielded the lowest root mean squared error in predicting Salmonella inactivation (1.1 to 1.5 log CFU/g); in contrast, E. faecium yielded a root mean squared error of 1.2 to 1.6 log CFU/g, and the traditional model yielded an unacceptably high error (3.4 to 4.4 log CFU/g). Importantly, the surrogate and modified model both yielded lethality predictions that were statistically equivalent (α = 0.05) to actual Salmonella lethality. The results demonstrate the importance of methodology, a w , and process humidity when validating thermal pasteurization processes for low-moisture foods, which should help processors select and interpret validation methods to ensure product safety.
Display format, highlight validity, and highlight method: Their effects on search performance
NASA Technical Reports Server (NTRS)
Donner, Kimberly A.; Mckay, Tim D.; Obrien, Kevin M.; Rudisill, Marianne
1991-01-01
Display format and highlight validity were shown to affect visual display search performance; however, these studies were conducted on small, artificial displays of alphanumeric stimuli. A study manipulating these variables was conducted using realistic, complex Space Shuttle information displays. A 2x2x3 within-subjects analysis of variance found that search times were faster for items in reformatted displays than for current displays. Responses to valid applications of highlight were significantly faster than responses to non or invalidly highlighted applications. The significant format by highlight validity interaction showed that there was little difference in response time to both current and reformatted displays when the highlight validity was applied; however, under the non or invalid highlight conditions, search times were faster with reformatted displays. A separate within-subject analysis of variance of display format, highlight validity, and several highlight methods did not reveal a main effect of highlight method. In addition, observed display search times were compared to search time predicted by Tullis' Display Analysis Program. Benefits of highlighting and reformatting displays to enhance search and the necessity to consider highlight validity and format characteristics in tandem for predicting search performance are discussed.
Mulder, Leontine; van der Molen, Renate; Koelman, Carin; van Leeuwen, Ester; Roos, Anja; Damoiseaux, Jan
2018-05-01
ISO 15189:2012 requires validation of methods used in the medical laboratory, and lists a series of performance parameters for consideration to include. Although these performance parameters are feasible for clinical chemistry analytes, application in the validation of autoimmunity tests is a challenge. Lack of gold standards or reference methods in combination with the scarcity of well-defined diagnostic samples of patients with rare diseases make validation of new assays difficult. The present manuscript describes the initiative of Dutch medical immunology laboratory specialists to combine efforts and perform multi-center validation studies of new assays in the field of autoimmunity. Validation data and reports are made available to interested Dutch laboratory specialists. Copyright © 2018 Elsevier B.V. All rights reserved.
Modeling, implementation, and validation of arterial travel time reliability.
DOT National Transportation Integrated Search
2013-11-01
Previous research funded by Florida Department of Transportation (FDOT) developed a method for estimating : travel time reliability for arterials. This method was not initially implemented or validated using field data. This : project evaluated and r...
Beasley, Christopher A; Shaw, Jessica; Zhao, Zack; Reed, Robert A
2005-03-09
The purpose of the research described herein was to develop and validate a stability-indicating HPLC method for lisinopril, lisinopril degradation product (DKP), methyl paraben and propyl paraben in a lisinopril extemporaneous formulation. The method developed in this report is selective for the components listed above, in the presence of the complex and chromatographically rich matrix presented by the Bicitra and Ora-Sweet SF formulation diluents. The method was also shown to have adequate sensitivity with a detection limit of 0.0075 microg/mL (0.03% of lisinopril method concentration). The validation elements investigated showed that the method has acceptable specificity, recovery, linearity, solution stability, and method precision. Acceptable robustness indicates that the assay method remains unaffected by small but deliberate variations, which are described in ICH Q2A and Q2B guidelines.
Quantitative bioanalysis of strontium in human serum by inductively coupled plasma-mass spectrometry
Somarouthu, Srikanth; Ohh, Jayoung; Shaked, Jonathan; Cunico, Robert L; Yakatan, Gerald; Corritori, Suzana; Tami, Joe; Foehr, Erik D
2015-01-01
Aim: A bioanalytical method using inductively-coupled plasma-mass spectrometry to measure endogenous levels of strontium in human serum was developed and validated. Results & methodology: This article details the experimental procedures used for the method development and validation thus demonstrating the application of the inductively-coupled plasma-mass spectrometry method for quantification of strontium in human serum samples. The assay was validated for specificity, linearity, accuracy, precision, recovery and stability. Significant endogenous levels of strontium are present in human serum samples ranging from 19 to 96 ng/ml with a mean of 34.6 ± 15.2 ng/ml (SD). Discussion & conclusion: Calibration procedures and sample pretreatment were simplified for high throughput analysis. The validation demonstrates that the method was sensitive, selective for quantification of strontium (88Sr) and is suitable for routine clinical testing of strontium in human serum samples. PMID:28031925
Li, Xue; Ahmad, Imad A Haidar; Tam, James; Wang, Yan; Dao, Gina; Blasko, Andrei
2018-02-05
A Total Organic Carbon (TOC) based analytical method to quantitate trace residues of clean-in-place (CIP) detergents CIP100 ® and CIP200 ® on the surfaces of pharmaceutical manufacturing equipment was developed and validated. Five factors affecting the development and validation of the method were identified: diluent composition, diluent volume, extraction method, location for TOC sample preparation, and oxidant flow rate. Key experimental parameters were optimized to minimize contamination and to improve the sensitivity, recovery, and reliability of the method. The optimized concentration of the phosphoric acid in the swabbing solution was 0.05M, and the optimal volume of the sample solution was 30mL. The swab extraction method was 1min sonication. The use of a clean room, as compared to an isolated lab environment, was not required for method validation. The method was demonstrated to be linear with a correlation coefficient (R) of 0.9999. The average recoveries from stainless steel surfaces at multiple spike levels were >90%. The repeatability and intermediate precision results were ≤5% across the 2.2-6.6ppm range (50-150% of the target maximum carry over, MACO, limit). The method was also shown to be sensitive with a detection limit (DL) of 38ppb and a quantitation limit (QL) of 114ppb. The method validation demonstrated that the developed method is suitable for its intended use. The methodology developed in this study is generally applicable to the cleaning verification of any organic detergents used for the cleaning of pharmaceutical manufacturing equipment made of electropolished stainless steel material. Copyright © 2017 Elsevier B.V. All rights reserved.
Predicting implementation from organizational readiness for change: a study protocol
2011-01-01
Background There is widespread interest in measuring organizational readiness to implement evidence-based practices in clinical care. However, there are a number of challenges to validating organizational measures, including inferential bias arising from the halo effect and method bias - two threats to validity that, while well-documented by organizational scholars, are often ignored in health services research. We describe a protocol to comprehensively assess the psychometric properties of a previously developed survey, the Organizational Readiness to Change Assessment. Objectives Our objective is to conduct a comprehensive assessment of the psychometric properties of the Organizational Readiness to Change Assessment incorporating methods specifically to address threats from halo effect and method bias. Methods and Design We will conduct three sets of analyses using longitudinal, secondary data from four partner projects, each testing interventions to improve the implementation of an evidence-based clinical practice. Partner projects field the Organizational Readiness to Change Assessment at baseline (n = 208 respondents; 53 facilities), and prospectively assesses the degree to which the evidence-based practice is implemented. We will conduct predictive and concurrent validities using hierarchical linear modeling and multivariate regression, respectively. For predictive validity, the outcome is the change from baseline to follow-up in the use of the evidence-based practice. We will use intra-class correlations derived from hierarchical linear models to assess inter-rater reliability. Two partner projects will also field measures of job satisfaction for convergent and discriminant validity analyses, and will field Organizational Readiness to Change Assessment measures at follow-up for concurrent validity (n = 158 respondents; 33 facilities). Convergent and discriminant validities will test associations between organizational readiness and different aspects of job satisfaction: satisfaction with leadership, which should be highly correlated with readiness, versus satisfaction with salary, which should be less correlated with readiness. Content validity will be assessed using an expert panel and modified Delphi technique. Discussion We propose a comprehensive protocol for validating a survey instrument for assessing organizational readiness to change that specifically addresses key threats of bias related to halo effect, method bias and questions of construct validity that often go unexplored in research using measures of organizational constructs. PMID:21777479
ERIC Educational Resources Information Center
Kimaru, Irene; Koether, Marina; Chichester, Kimberly; Eaton, Lafayette
2017-01-01
Analytical method transfer (AMT) and dissolution testing are important topics required in industry that should be taught in analytical chemistry courses. Undergraduate students in senior level analytical chemistry laboratory courses at Kennesaw State University (KSU) and St. John Fisher College (SJFC) participated in development, validation, and…
USDA-ARS?s Scientific Manuscript database
The aim of this study was to determine the validity of energy intake (EI) estimations made using the remote food photography method (RFPM) compared to the doubly labeled water (DLW) method in minority preschool children in a free-living environment. Seven days of food intake and spot urine samples...
Triangulation, Respondent Validation, and Democratic Participation in Mixed Methods Research
ERIC Educational Resources Information Center
Torrance, Harry
2012-01-01
Over the past 10 years or so the "Field" of "Mixed Methods Research" (MMR) has increasingly been exerting itself as something separate, novel, and significant, with some advocates claiming paradigmatic status. Triangulation is an important component of mixed methods designs. Triangulation has its origins in attempts to validate research findings…
Illustrating a Mixed-Method Approach for Validating Culturally Specific Constructs
ERIC Educational Resources Information Center
Hitchcock, J.H.; Nastasi, B.K.; Dai, D.Y.; Newman, J.; Jayasena, A.; Bernstein-Moore, R.; Sarkar, S.; Varjas, K.
2005-01-01
The purpose of this article is to illustrate a mixed-method approach (i.e., combining qualitative and quantitative methods) for advancing the study of construct validation in cross-cultural research. The article offers a detailed illustration of the approach using the responses 612 Sri Lankan adolescents provided to an ethnographic survey. Such…
Apostol, Izydor; Kelner, Drew; Jiang, Xinzhao Grace; Huang, Gang; Wypych, Jette; Zhang, Xin; Gastwirt, Jessica; Chen, Kenneth; Fodor, Szilan; Hapuarachchi, Suminda; Meriage, Dave; Ye, Frank; Poppe, Leszek; Szpankowski, Wojciech
2012-12-01
To predict precision and other performance characteristics of chromatographic purity methods, which represent the most widely used form of analysis in the biopharmaceutical industry. We have conducted a comprehensive survey of purity methods, and show that all performance characteristics fall within narrow measurement ranges. This observation was used to develop a model called Uncertainty Based on Current Information (UBCI), which expresses these performance characteristics as a function of the signal and noise levels, hardware specifications, and software settings. We applied the UCBI model to assess the uncertainty of purity measurements, and compared the results to those from conventional qualification. We demonstrated that the UBCI model is suitable to dynamically assess method performance characteristics, based on information extracted from individual chromatograms. The model provides an opportunity for streamlining qualification and validation studies by implementing a "live validation" of test results utilizing UBCI as a concurrent assessment of measurement uncertainty. Therefore, UBCI can potentially mitigate the challenges associated with laborious conventional method validation and facilitates the introduction of more advanced analytical technologies during the method lifecycle.
Bajerski, Lisiane; Rossi, Rochele Cassanta; Dias, Carolina Lupi; Bergold, Ana Maria; Fröehlich, Pedro Eduardo
2010-06-01
A dissolution test for tablets containing 40 mg of olmesartan medoxomil (OLM) was developed and validated using both LC-UV and UV methods. After evaluation of the sink condition, dissolution medium, and stability of the drug, the method was validated using USP apparatus 2, 50 rpm rotation speed, and 900 ml of deaerated H(2)O + 0.5% sodium lauryl sulfate (w/v) at pH 6.8 (adjusted with 18% phosphoric acid) as the dissolution medium. The model-independent method using difference factor (f(1)) and similarity factor (f(2)), model-dependent method, and dissolution efficiency were employed to compare dissolution profiles. The kinetic parameters of drug release were also investigated. The obtained results provided adequate dissolution profiles. The developed dissolution test was validated according to international guidelines. Since there is no monograph for this drug in tablets, the dissolution method presented here can be used as a quality control test for OLM in this dosage form, especially in a batch to batch evaluation.
The construct validity of session RPE during an intensive camp in young male Karate athletes
Padulo, Johnny; Chaabène, Helmi; Tabben, Montassar; Haddad, Monoem; Gevat, Cecilia; Vando, Stefano; Maurino, Lucio; Chaouachi, Anis; Chamari, Karim
2014-01-01
Summary Background: the aim of this study was to assess the validity of the session rating of perceived exertion (RPE) method and two objective HR-based methods for quantifying karate’s training load (TL) in young Karatekas. Methods: eleven athletes (age 12.50±1.84 years) participated in this study. The training period/camp was performed on 5 consecutive days with two training session (s) per-day (d). Construct validity of RPE method in young Karate athletes, was studied by correlation analysis between RPE session’s training load and both Edwards and Banister’s training impulse score’ method. Results: significant relationship was found between inter-day (n-11 × d-5 × s-2 = 110) sessions RPE and Edwards (r values from 0.84 to 0.92 p < 0.001) and Banister’s (r values from 0.84 to 0.97 p < 0.001), respectively Conclusion: this study showed that session-RPE can be considered a valid method for quantifying karate’s training load in young karate athletes. PMID:25332921
Subramanian, Venkatesan; Nagappan, Kannappan; Sandeep Mannemala, Sai
2015-01-01
A sensitive, accurate, precise and rapid HPLC-PDA method was developed and validated for the simultaneous determination of torasemide and spironolactone in human plasma using Design of experiments. Central composite design was used to optimize the method using content of acetonitrile, concentration of buffer and pH of mobile phase as independent variables, while the retention factor of spironolactone, resolution between torasemide and phenobarbitone; and retention time of phenobarbitone were chosen as dependent variables. The chromatographic separation was achieved on Phenomenex C(18) column and the mobile phase comprising 20 mM potassium dihydrogen ortho phosphate buffer (pH-3.2) and acetonitrile in 82.5:17.5 v/v pumped at a flow rate of 1.0 mL min(-1). The method was validated according to USFDA guidelines in terms of selectivity, linearity, accuracy, precision, recovery and stability. The limit of quantitation values were 80 and 50 ng mL(-1) for torasemide and spironolactone respectively. Furthermore, the sensitivity and simplicity of the method suggests the validity of method for routine clinical studies.
Dobecki, Marek
2012-01-01
This paper reviews the requirements for measurement methods of chemical agents in the air at workstations. European standards, which have a status of Polish standards, comprise some requirements and information on sampling strategy, measuring techniques, type of samplers, sampling pumps and methods of occupational exposure evaluation at a given technological process. Measurement methods, including air sampling and analytical procedure in a laboratory, should be appropriately validated before intended use. In the validation process, selected methods are tested and budget of uncertainty is set up. The validation procedure that should be implemented in the laboratory together with suitable statistical tools and major components of uncertainity to be taken into consideration, were presented in this paper. Methods of quality control, including sampling and laboratory analyses were discussed. Relative expanded uncertainty for each measurement expressed as a percentage, should not exceed the limit of values set depending on the type of occupational exposure (short-term or long-term) and the magnitude of exposure to chemical agents in the work environment.
Rezende, Vinícius Marcondes; Rivellis, Ariane Julio; Gomes, Melissa Medrano; Dörr, Felipe Augusto; Novaes, Mafalda Megumi Yoshinaga; Nardinelli, Luciana; Costa, Ariel Lais de Lima; Chamone, Dalton de Alencar Fisher; Bendit, Israel
2013-01-01
Objective The goal of this study was to monitor imatinib mesylate therapeutically in the Tumor Biology Laboratory, Department of Hematology and Hemotherapy, Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo (USP). A simple and sensitive method to quantify imatinib and its metabolite (CGP74588) in human serum was developed and fully validated in order to monitor treatment compliance. Methods The method used to quantify these compounds in serum included protein precipitation extraction followed by instrumental analysis using high performance liquid chromatography coupled with mass spectrometry. The method was validated for several parameters, including selectivity, precision, accuracy, recovery and linearity. Results The parameters evaluated during the validation stage exhibited satisfactory results based on the Food and Drug Administration and the Brazilian Health Surveillance Agency (ANVISA) guidelines for validating bioanalytical methods. These parameters also showed a linear correlation greater than 0.99 for the concentration range between 0.500 µg/mL and 10.0 µg/mL and a total analysis time of 13 minutes per sample. This study includes results (imatinib serum concentrations) for 308 samples from patients being treated with imatinib mesylate. Conclusion The method developed in this study was successfully validated and is being efficiently used to measure imatinib concentrations in samples from chronic myeloid leukemia patients to check treatment compliance. The imatinib serum levels of patients achieving a major molecular response were significantly higher than those of patients who did not achieve this result. These results are thus consistent with published reports concerning other populations. PMID:23741187
Kumar, Navneet; Sangeetha, D.; Balakrishna, P.
2011-01-01
Background: In pharmaceutical industries, it is very important to remove drug residues from the equipment and areas used. The cleaning procedure must be validated, so special attention must be devoted to the methods used for analysis of trace amounts of drugs. A rapid, sensitive, and specific reverse phase ultra-performance liquid chromatographic (UPLC) method was developed for the quantitative determination of duloxetine in cleaning validation swab samples. Material and Methods: The method was validated using an Acquity UPLC™ HSS T3 (100 × 2.1 mm2) 1.8 μm column with a isocratic mobile phase containing a mixture of 0.01 M potassium dihydrogen orthophosphate, pH adjusted to 3.0 with orthophosphoric acid and acetonitrile (60:40 v/v). The flow rate of the mobile phase was 0.4 ml/min with a column temperature of 40°C and detection wavelength at 230 nm. Cotton swabs, moisten with extraction solution (90% methanol and 10% water), were used to remove any residue of drug from stainless steel, glass and silica surfaces, and give recoveries >80% at four concentration levels. Results: The precision of the results, reported as the relative standard deviation, were below 1.5%. The calibration curve was linear over a concentration range from 0.02 to 5.0 μg/ml with a correlation coefficient of 0.999. The detection limit and quantitation limit were 0.006 and 0.02 μg/ml, respectively. The method was validated over a concentration range of 0.05–5.0 μg/ml. Conclusion: The developed method was validated with respect to specificity, linearity, limit of detection and quantification, accuracy, precision, and robustness. PMID:23781449
Peck, Michelle A; Sturk-Andreaggi, Kimberly; Thomas, Jacqueline T; Oliver, Robert S; Barritt-Ross, Suzanne; Marshall, Charla
2018-05-01
Generating mitochondrial genome (mitogenome) data from reference samples in a rapid and efficient manner is critical to harnessing the greater power of discrimination of the entire mitochondrial DNA (mtDNA) marker. The method of long-range target enrichment, Nextera XT library preparation, and Illumina sequencing on the MiSeq is a well-established technique for generating mitogenome data from high-quality samples. To this end, a validation was conducted for this mitogenome method processing up to 24 samples simultaneously along with analysis in the CLC Genomics Workbench and utilizing the AQME (AFDIL-QIAGEN mtDNA Expert) tool to generate forensic profiles. This validation followed the Federal Bureau of Investigation's Quality Assurance Standards (QAS) for forensic DNA testing laboratories and the Scientific Working Group on DNA Analysis Methods (SWGDAM) validation guidelines. The evaluation of control DNA, non-probative samples, blank controls, mixtures, and nonhuman samples demonstrated the validity of this method. Specifically, the sensitivity was established at ≥25 pg of nuclear DNA input for accurate mitogenome profile generation. Unreproducible low-level variants were observed in samples with low amplicon yields. Further, variant quality was shown to be a useful metric for identifying sequencing error and crosstalk. Success of this method was demonstrated with a variety of reference sample substrates and extract types. These studies further demonstrate the advantages of using NGS techniques by highlighting the quantitative nature of heteroplasmy detection. The results presented herein from more than 175 samples processed in ten sequencing runs, show this mitogenome sequencing method and analysis strategy to be valid for the generation of reference data. Copyright © 2018 Elsevier B.V. All rights reserved.
Mudge, Elizabeth; Paley, Lori; Schieber, Andreas; Brown, Paula N
2015-10-01
Seeds of milk thistle, Silybum marianum (L.) Gaertn., are used for treatment and prevention of liver disorders and were identified as a high priority ingredient requiring a validated analytical method. An AOAC International expert panel reviewed existing methods and made recommendations concerning method optimization prior to validation. A series of extraction and separation studies were undertaken on the selected method for determining flavonolignans from milk thistle seeds and finished products to address the review panel recommendations. Once optimized, a single-laboratory validation study was conducted. The method was assessed for repeatability, accuracy, selectivity, LOD, LOQ, analyte stability, and linearity. Flavonolignan content ranged from 1.40 to 52.86% in raw materials and dry finished products and ranged from 36.16 to 1570.7 μg/mL in liquid tinctures. Repeatability for the individual flavonolignans in raw materials and finished products ranged from 1.03 to 9.88% RSDr, with HorRat values between 0.21 and 1.55. Calibration curves for all flavonolignan concentrations had correlation coefficients of >99.8%. The LODs for the flavonolignans ranged from 0.20 to 0.48 μg/mL at 288 nm. Based on the results of this single-laboratory validation, this method is suitable for the quantitation of the six major flavonolignans in milk thistle raw materials and finished products, as well as multicomponent products containing dandelion, schizandra berry, and artichoke extracts. It is recommended that this method be adopted as First Action Official Method status by AOAC International.
NASA Astrophysics Data System (ADS)
Moustafa, Azza Aziz; Salem, Hesham; Hegazy, Maha; Ali, Omnia
2015-02-01
Simple, accurate, and selective methods have been developed and validated for simultaneous determination of a ternary mixture of Chlorpheniramine maleate (CPM), Pseudoephedrine HCl (PSE) and Ibuprofen (IBF), in tablet dosage form. Four univariate methods manipulating ratio spectra were applied, method A is the double divisor-ratio difference spectrophotometric method (DD-RD). Method B is double divisor-derivative ratio spectrophotometric method (DD-RD). Method C is derivative ratio spectrum-zero crossing method (DRZC), while method D is mean centering of ratio spectra (MCR). Two multivariate methods were also developed and validated, methods E and F are Principal Component Regression (PCR) and Partial Least Squares (PLSs). The proposed methods have the advantage of simultaneous determination of the mentioned drugs without prior separation steps. They were successfully applied to laboratory-prepared mixtures and to commercial pharmaceutical preparation without any interference from additives. The proposed methods were validated according to the ICH guidelines. The obtained results were statistically compared with the official methods where no significant difference was observed regarding both accuracy and precision.
Shum, Bennett O V; Henner, Ilya; Belluoccio, Daniele; Hinchcliffe, Marcus J
2017-07-01
The sensitivity and specificity of next-generation sequencing laboratory developed tests (LDTs) are typically determined by an analyte-specific approach. Analyte-specific validations use disease-specific controls to assess an LDT's ability to detect known pathogenic variants. Alternatively, a methods-based approach can be used for LDT technical validations. Methods-focused validations do not use disease-specific controls but use benchmark reference DNA that contains known variants (benign, variants of unknown significance, and pathogenic) to assess variant calling accuracy of a next-generation sequencing workflow. Recently, four whole-genome reference materials (RMs) from the National Institute of Standards and Technology (NIST) were released to standardize methods-based validations of next-generation sequencing panels across laboratories. We provide a practical method for using NIST RMs to validate multigene panels. We analyzed the utility of RMs in validating a novel newborn screening test that targets 70 genes, called NEO1. Despite the NIST RM variant truth set originating from multiple sequencing platforms, replicates, and library types, we discovered a 5.2% false-negative variant detection rate in the RM truth set genes that were assessed in our validation. We developed a strategy using complementary non-RM controls to demonstrate 99.6% sensitivity of the NEO1 test in detecting variants. Our findings have implications for laboratories or proficiency testing organizations using whole-genome NIST RMs for testing. Copyright © 2017 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Burton, Laura J.; Mazerolle, Stephanie M.
2011-01-01
Context: Instrument validation is an important facet of survey research methods and athletic trainers must be aware of the important underlying principles. Objective: To discuss the process of survey development and validation, specifically the process of construct validation. Background: Athletic training researchers frequently employ the use of…
ERIC Educational Resources Information Center
Myers, Nicholas D.; Ahn, Soyeon; Jin, Ying
2011-01-01
Monte Carlo methods can be used in data analytic situations (e.g., validity studies) to make decisions about sample size and to estimate power. The purpose of using Monte Carlo methods in a validity study is to improve the methodological approach within a study where the primary focus is on construct validity issues and not on advancing…
ERIC Educational Resources Information Center
Demiray, Esra; Isiksal Bostan, Mine
2017-01-01
The purposes of this study are to investigate Turkish pre-service middle school mathematics teachers' ability in conducting valid proofs for statements regarding numbers and algebra in terms of their year of enrollment in a teacher education program, to determine the proof methods used in their valid proofs, and to examine the reasons for their…
Zhang, Zhaoyang; Fang, Hua; Wang, Honggang
2016-06-01
Web-delivered trials are an important component in eHealth services. These trials, mostly behavior-based, generate big heterogeneous data that are longitudinal, high dimensional with missing values. Unsupervised learning methods have been widely applied in this area, however, validating the optimal number of clusters has been challenging. Built upon our multiple imputation (MI) based fuzzy clustering, MIfuzzy, we proposed a new multiple imputation based validation (MIV) framework and corresponding MIV algorithms for clustering big longitudinal eHealth data with missing values, more generally for fuzzy-logic based clustering methods. Specifically, we detect the optimal number of clusters by auto-searching and -synthesizing a suite of MI-based validation methods and indices, including conventional (bootstrap or cross-validation based) and emerging (modularity-based) validation indices for general clustering methods as well as the specific one (Xie and Beni) for fuzzy clustering. The MIV performance was demonstrated on a big longitudinal dataset from a real web-delivered trial and using simulation. The results indicate MI-based Xie and Beni index for fuzzy-clustering are more appropriate for detecting the optimal number of clusters for such complex data. The MIV concept and algorithms could be easily adapted to different types of clustering that could process big incomplete longitudinal trial data in eHealth services.
Zhang, Zhaoyang; Wang, Honggang
2016-01-01
Web-delivered trials are an important component in eHealth services. These trials, mostly behavior-based, generate big heterogeneous data that are longitudinal, high dimensional with missing values. Unsupervised learning methods have been widely applied in this area, however, validating the optimal number of clusters has been challenging. Built upon our multiple imputation (MI) based fuzzy clustering, MIfuzzy, we proposed a new multiple imputation based validation (MIV) framework and corresponding MIV algorithms for clustering big longitudinal eHealth data with missing values, more generally for fuzzy-logic based clustering methods. Specifically, we detect the optimal number of clusters by auto-searching and -synthesizing a suite of MI-based validation methods and indices, including conventional (bootstrap or cross-validation based) and emerging (modularity-based) validation indices for general clustering methods as well as the specific one (Xie and Beni) for fuzzy clustering. The MIV performance was demonstrated on a big longitudinal dataset from a real web-delivered trial and using simulation. The results indicate MI-based Xie and Beni index for fuzzy-clustering is more appropriate for detecting the optimal number of clusters for such complex data. The MIV concept and algorithms could be easily adapted to different types of clustering that could process big incomplete longitudinal trial data in eHealth services. PMID:27126063
Measuring Adverse Events in Helicopter Emergency Medical Services: Establishing Content Validity
Patterson, P. Daniel; Lave, Judith R.; Martin-Gill, Christian; Weaver, Matthew D.; Wadas, Richard J.; Arnold, Robert M.; Roth, Ronald N.; Mosesso, Vincent N.; Guyette, Francis X.; Rittenberger, Jon C.; Yealy, Donald M.
2015-01-01
Introduction We sought to create a valid framework for detecting Adverse Events (AEs) in the high-risk setting of Helicopter Emergency Medical Services (HEMS). Methods We assembled a panel of 10 expert clinicians (n=6 emergency medicine physicians and n=4 prehospital nurses and flight paramedics) affiliated with a large multi-state HEMS organization in the Northeast U.S. We used a modified Delphi technique to develop a framework for detecting AEs associated with the treatment of critically ill or injured patients. We used a widely applied measure, the Content Validity Index (CVI), to quantify the validity of the framework’s content. Results The expert panel of 10 clinicians reached consensus on a common AE definition and four-step protocol/process for AE detection in HEMS. The consensus-based framework is composed of three main components: 1) a trigger tool, 2) a method for rating proximal cause, and 3) a method for rating AE severity. The CVI findings isolate components of the framework considered content valid. Conclusions We demonstrate a standardized process for the development of a content valid framework for AE detection. The framework is a model for the development of a method for AE identification in other settings, including ground-based EMS. PMID:24003951
PRN 96-1: Tolerance Enforcement Methods - Independent Laboratory Validation by Petitioner
This notice is intended to clarify the requirements for submission of an Independent Laboratory Validation to accompany new pesticide analytical methods and does not contain additional data requirements.This notice supersedes PR Notice 88-5.
Testing Standard Reliability Criteria
ERIC Educational Resources Information Center
Sherry, David
2017-01-01
Maul's paper, "Rethinking Traditional Methods of Survey Validation" (Andrew Maul), contains two stages. First he presents empirical results that cast doubt on traditional methods for validating psychological measurement instruments. These results motivate the second stage, a critique of current conceptions of psychological measurement…
Reeves, Todd D.; Marbach-Ad, Gili
2016-01-01
Most discipline-based education researchers (DBERs) were formally trained in the methods of scientific disciplines such as biology, chemistry, and physics, rather than social science disciplines such as psychology and education. As a result, DBERs may have never taken specific courses in the social science research methodology—either quantitative or qualitative—on which their scholarship often relies so heavily. One particular aspect of (quantitative) social science research that differs markedly from disciplines such as biology and chemistry is the instrumentation used to quantify phenomena. In response, this Research Methods essay offers a contemporary social science perspective on test validity and the validation process. The instructional piece explores the concepts of test validity, the validation process, validity evidence, and key threats to validity. The essay also includes an in-depth example of a validity argument and validation approach for a test of student argument analysis. In addition to DBERs, this essay should benefit practitioners (e.g., lab directors, faculty members) in the development, evaluation, and/or selection of instruments for their work assessing students or evaluating pedagogical innovations. PMID:26903498
Miles, Dale R; Mesfin, Mimi; Mody, Tarak D; Stiles, Mark; Lee, Jean; Fiene, John; Denis, Bernie; Boswell, Garry W
2006-05-01
Liquid chromatography-fluorescence (LC-FLS), liquid chromatography-tandem mass spectrometry (LC-MS/MS) and inductively coupled plasma-mass spectrometry (ICP-MS) methods were developed and validated for the evaluation of motexafin gadolinium (MGd, Xcytrin) pharmacokinetics and biodistribution in plasma and tissues. The LC-FLS method exhibited the greatest sensitivity (0.0057 microg mL(-1)), and was used for pharmacokinetic, biodistribution, and protein binding studies with small sample sizes or low MGd concentrations. The LC-MS/MS method, which exhibited a short run time and excellent selectivity, was used for routine clinical plasma sample analysis. The ICP-MS method, which measured total Gd, was used in conjunction with LC methods to assess MGd stability in plasma. All three methods were validated using human plasma. The LC-FLS method was also validated using plasma, liver and kidneys from mice and rats. All three methods were shown to be accurate, precise and robust for each matrix validated. For three mice, the mean (standard deviation) concentration of MGd in plasma/tissues taken 5 hr after dosing with 23 mg kg(-1) MGd was determined by LC-FLS as follows: plasma (0.025+/-0.002 microg mL(-1)), liver (2.89+/-0.45 microg g(-1)), and kidney (6.09+/-1.05 microg g(-1)). Plasma samples from a subset of patients with brain metastases from extracranial tumors were analyzed using both LC-MS/MS and ICP-MS methods. For a representative patient, > or = 90% of the total Gd in plasma was accounted for as MGd over the first hour post dosing. By 24 hr post dosing, 63% of total Gd was accounted for as MGd, indicating some metabolism of MGd.
Bellur Atici, Esen; Yazar, Yücel; Ağtaş, Çağan; Ridvanoğlu, Nurten; Karlığa, Bekir
2017-03-20
Antibacterial combinations consisting of the semisynthetic antibiotic amoxicillin (amox) and the β-lactamase inhibitor potassium clavulanate (clav) are commonly used and several chromatographic methods were reported for their quantification in mixtures. In the present work, single HPLC method for related substances analyses of amoxicillin and potassium clavulanate mixtures was developed and validated according to international conference on harmonization (ICH) guidelines. Eighteen amoxicillin and six potassium clavulanate impurities were successfully separated from each other by using triple gradient elution using a Thermo Hypersil Zorbax BDS C18 (250 mm×4.6mm, 3μm) column with 50μL injection volumes at a wavelength of 215nm. Commercially unavailable impurities were formed by degradation of amoxicillin and potassium clavulanate, identified by LC-MS studies and used during analytical method development and validation studies. Also, process related amoxicillin impurity-P was synthesized and characterized by using nuclear magnetic resonance (NMR) and mass spectroscopy (MS) for the first time. As complementary of this work, an assay method for amoxicillin and potassium clavulanate mixtures was developed and validated; stress-testing and stability studies of amox/clav mixtures was carried out under specified conditions according to ICH and analyzed by using validated stability-indicating assay and related substances methods. Copyright © 2016 Elsevier B.V. All rights reserved.
Postcraniometric sex and ancestry estimation in South Africa: a validation study.
Liebenberg, Leandi; Krüger, Gabriele C; L'Abbé, Ericka N; Stull, Kyra E
2018-05-24
With the acceptance of the Daubert criteria as the standards for best practice in forensic anthropological research, more emphasis is being placed on the validation of published methods. Methods, both traditional and novel, need to be validated, adjusted, and refined for optimal performance within forensic anthropological analyses. Recently, a custom postcranial database of modern South Africans was created for use in Fordisc 3.1. Classification accuracies of up to 85% for ancestry estimation and 98% for sex estimation were achieved using a multivariate approach. To measure the external validity and report more realistic performance statistics, an independent sample was tested. The postcrania from 180 black, white, and colored South Africans were measured and classified using the custom postcranial database. A decrease in accuracy was observed for both ancestry estimation (79%) and sex estimation (95%) of the validation sample. When incorporating both sex and ancestry simultaneously, the method achieved 70% accuracy, and 79% accuracy when sex-specific ancestry analyses were run. Classification matrices revealed that postcrania were more likely to misclassify as a result of ancestry rather than sex. While both sex and ancestry influence the size of an individual, sex differences are more marked in the postcranial skeleton and are therefore easier to identify. The external validity of the postcranial database was verified and therefore shown to be a useful tool for forensic casework in South Africa. While the classification rates were slightly lower than the original method, this is expected when a method is generalized.
Bohm, Detlef A; Stachel, Carolin S; Gowik, Petra
2012-07-01
The presented multi-method was developed for the confirmation of 37 antibiotic substances from the six antibiotic groups: macrolides, lincosamides, quinolones, tetracyclines, pleuromutilines and diamino-pyrimidine derivatives. All substances were analysed simultaneously in a single analytical run with the same procedure, including an extraction with buffer, a clean-up by solid-phase extraction, and the measurement by liquid chromatography tandem mass spectrometry in ESI+ mode. The method was validated on the basis of an in-house validation concept with factorial design by combination of seven factors to check the robustness in a concentration range of 5-50 μg kg(-1). The honeys used were of different types with regard to colour and origin. The values calculated for the validation parameters-decision limit CCα (range, 7.5-12.9 μg kg(-1)), detection capability CCβ (range, 9.4-19.9 μg kg(-1)), within-laboratory reproducibility RSD(wR) (<20% except for tulathromycin with 23.5% and tylvalosin with 21.4 %), repeatability RSD(r) (<20% except for tylvalosin with 21.1%), and recovery (range, 92-106%)-were acceptable and in agreement with the criteria of Commission Decision 2002/657/EC. The validation results showed that the method was applicable for the residue analysis of antibiotics in honey to substances with and without recommended concentrations, although some changes had been tested during validation to determine the robustness of the method.
Santiago, E C; Bello, F B B
2003-06-01
The Association of Official Analytical Chemists (AOAC) Standard Method 972.23 (dry ashing and flame atomic absorption spectrophotometry (FAAS)), applied to the analysis of lead in tuna, was validated in three selected local laboratories to determine the acceptability of the method to both the Codex Alimentarius Commission (Codex) and the European Union (EU) Commission for monitoring lead in canned tuna. Initial validation showed that the standard AOAC method as performed in the three participating laboratories cannot satisfy the Codex/EU proposed criteria for the method detection limit for monitoring lead in fish at the present regulation level of 0.5 mg x kg(-1). Modification of the standard method by chelation/concentration of the digest solution before FAAS analysis showed that the modified method has the potential to meet Codex/EU criteria on sensitivity, accuracy and precision at the specified regulation level.
Gutiérrez-Vilahú, Lourdes; Massó-Ortigosa, Núria; Rey-Abella, Ferran; Costa-Tutusaus, Lluís; Guerra-Balic, Myriam
2016-05-01
People with Down syndrome present skeletal abnormalities in their feet that can be analyzed by commonly used gold standard indices (the Hernández-Corvo index, the Chippaux-Smirak index, the Staheli arch index, and the Clarke angle) based on footprint measurements. The use of Photoshop CS5 software (Adobe Systems Software Ireland Ltd, Dublin, Ireland) to measure footprints has been validated in the general population. The present study aimed to assess the reliability and validity of this footprint assessment technique in the population with Down syndrome. Using optical podography and photography, 44 footprints from 22 patients with Down syndrome (11 men [mean ± SD age, 23.82 ± 3.12 years] and 11 women [mean ± SD age, 24.82 ± 6.81 years]) were recorded in a static bipedal standing position. A blinded observer performed the measurements using a validated manual method three times during the 4-month study, with 2 months between measurements. Test-retest was used to check the reliability of the Photoshop CS5 software measurements. Validity and reliability were obtained by intraclass correlation coefficient (ICC). The reliability test for all of the indices showed very good values for the Photoshop CS5 method (ICC, 0.982-0.995). Validity testing also found no differences between the techniques (ICC, 0.988-0.999). The Photoshop CS5 software method is reliable and valid for the study of footprints in young people with Down syndrome.
[Selection of risk and diagnosis in diabetic polyneuropathy. Validation of method of new systems].
Jurado, Jerónimo; Caula, Jacinto; Pou i Torelló, Josep Maria
2006-06-30
In a previous study we developed a specific algorithm, the polyneuropathy selection method (PSM) with 4 parameters (age, HDL-C, HbA1c, and retinopathy), to select patients at risk of diabetic polyneuropathy (DPN). We also developed a simplified method for DPN diagnosis: outpatient polyneuropathy diagnosis (OPD), with 4 variables (symptoms and 3 objective tests). To confirm the validity of conventional tests for DPN diagnosis; to validate the discriminatory power of the PSM and the diagnostic value of OPD by evaluating their relationship to electrodiagnosis studies and objective clinical neurological assessment; and to evaluate the correlation of DPN and pro-inflammatory status. Cross-sectional, crossed association for PSM validation. Paired samples for OPD validation. Primary care in 3 counties. Random sample of 75 subjects from the type-2 diabetes census for PSM evaluation. Thirty DPN patients and 30 non-DPN patients (from 2 DM2 sub-groups in our earlier study) for OPD evaluation. The gold standard for DPN diagnosis will be studied by means of a clinical neurological study (symptoms, physical examination, and sensitivity tests) and electrodiagnosis studies (sensitivity and motor EMG). Risks of neuropathy, macroangiopathy and pro-inflammatory status (PCR, TNF soluble fraction and total TGF-beta1) will be studied in every subject. Electrodiagnosis studies should confirm the validity of conventional tests for DPN diagnosis. PSM and OPD will be valid methods for selecting patients at risk and diagnosing DPN. There will be a significant relationship between DPN and pro-inflammatory tests.
Cross-validation to select Bayesian hierarchical models in phylogenetics.
Duchêne, Sebastián; Duchêne, David A; Di Giallonardo, Francesca; Eden, John-Sebastian; Geoghegan, Jemma L; Holt, Kathryn E; Ho, Simon Y W; Holmes, Edward C
2016-05-26
Recent developments in Bayesian phylogenetic models have increased the range of inferences that can be drawn from molecular sequence data. Accordingly, model selection has become an important component of phylogenetic analysis. Methods of model selection generally consider the likelihood of the data under the model in question. In the context of Bayesian phylogenetics, the most common approach involves estimating the marginal likelihood, which is typically done by integrating the likelihood across model parameters, weighted by the prior. Although this method is accurate, it is sensitive to the presence of improper priors. We explored an alternative approach based on cross-validation that is widely used in evolutionary analysis. This involves comparing models according to their predictive performance. We analysed simulated data and a range of viral and bacterial data sets using a cross-validation approach to compare a variety of molecular clock and demographic models. Our results show that cross-validation can be effective in distinguishing between strict- and relaxed-clock models and in identifying demographic models that allow growth in population size over time. In most of our empirical data analyses, the model selected using cross-validation was able to match that selected using marginal-likelihood estimation. The accuracy of cross-validation appears to improve with longer sequence data, particularly when distinguishing between relaxed-clock models. Cross-validation is a useful method for Bayesian phylogenetic model selection. This method can be readily implemented even when considering complex models where selecting an appropriate prior for all parameters may be difficult.
Reliability and Validity of the Footprint Assessment Method Using Photoshop CS5 Software.
Gutiérrez-Vilahú, Lourdes; Massó-Ortigosa, Núria; Costa-Tutusaus, Lluís; Guerra-Balic, Myriam
2015-05-01
Several sophisticated methods of footprint analysis currently exist. However, it is sometimes useful to apply standard measurement methods of recognized evidence with an easy and quick application. We sought to assess the reliability and validity of a new method of footprint assessment in a healthy population using Photoshop CS5 software (Adobe Systems Inc, San Jose, California). Forty-two footprints, corresponding to 21 healthy individuals (11 men with a mean ± SD age of 20.45 ± 2.16 years and 10 women with a mean ± SD age of 20.00 ± 1.70 years) were analyzed. Footprints were recorded in static bipedal standing position using optical podography and digital photography. Three trials for each participant were performed. The Hernández-Corvo, Chippaux-Smirak, and Staheli indices and the Clarke angle were calculated by manual method and by computerized method using Photoshop CS5 software. Test-retest was used to determine reliability. Validity was obtained by intraclass correlation coefficient (ICC). The reliability test for all of the indices showed high values (ICC, 0.98-0.99). Moreover, the validity test clearly showed no difference between techniques (ICC, 0.99-1). The reliability and validity of a method to measure, assess, and record the podometric indices using Photoshop CS5 software has been demonstrated. This provides a quick and accurate tool useful for the digital recording of morphostatic foot study parameters and their control.
Mochizuki, Ayumi; Ieki, Katsunori; Kamimori, Hiroshi; Nagao, Akemi; Nakai, Keiko; Nakayama, Akira; Nanba, Eitaro
2018-04-01
The guidance and several guidelines on bioanalytical method validation, which were issued by the US FDA, EMA and Ministry of Health, Labour and Welfare, list the 'full' validation parameters; however, none of these provide any details for 'partial' validation. Japan Bioanalysis Forum approved a total of three annual discussion groups from 2012 to 2014. In the discussion groups, members from pharmaceutical companies and contract research organizations discussed the details of partial validation from a risk assessment viewpoint based on surveys focusing on bioanalysis of small molecules using LC-MS/MS in Japan. This manuscript presents perspectives and recommendations for most conceivable changes that can be made to full and partial validations by members of the discussion groups based on their experiences and discussions at the Japan Bioanalysis Forum Symposium.
A Tale of Two Methods: Chart and Interview Methods for Identifying Delirium
Saczynski, Jane S.; Kosar, Cyrus M.; Xu, Guoquan; Puelle, Margaret R.; Schmitt, Eva; Jones, Richard N.; Marcantonio, Edward R.; Wong, Bonnie; Isaza, Ilean; Inouye, Sharon K.
2014-01-01
Background Interview and chart-based methods for identifying delirium have been validated. However, relative strengths and limitations of each method have not been described, nor has a combined approach (using both interviews and chart), been systematically examined. Objectives To compare chart and interview-based methods for identification of delirium. Design, Setting and Participants Participants were 300 patients aged 70+ undergoing major elective surgery (majority were orthopedic surgery) interviewed daily during hospitalization for delirium using the Confusion Assessment Method (CAM; interview-based method) and whose medical charts were reviewed for delirium using a validated chart-review method (chart-based method). We examined rate of agreement on the two methods and patient characteristics of those identified using each approach. Predictive validity for clinical outcomes (length of stay, postoperative complications, discharge disposition) was compared. In the absence of a gold-standard, predictive value could not be calculated. Results The cumulative incidence of delirium was 23% (n= 68) by the interview-based method, 12% (n=35) by the chart-based method and 27% (n=82) by the combined approach. Overall agreement was 80%; kappa was 0.30. The methods differed in detection of psychomotor features and time of onset. The chart-based method missed delirium in CAM-identified patients laacking features of psychomotor agitation or inappropriate behavior. The CAM-based method missed chart-identified cases occurring during the night shift. The combined method had high predictive validity for all clinical outcomes. Conclusions Interview and chart-based methods have specific strengths for identification of delirium. A combined approach captures the largest number and the broadest range of delirium cases. PMID:24512042
ERIC Educational Resources Information Center
Gagnon, Micheline; And Others
1983-01-01
A method for determining the tridimensional angular displacement of skates during the two-legged stop in ice hockey was developed and validated. The angles were measured by geometry, using a cinecamera and specially equipped skates. The method provides a new tool for kinetic analyses of skating movements. (Authors/PP)
Determination of Trace Elements in Uranium by HPLC-ID-ICP-MS: NTNFC Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Manard, Benjamin Thomas; Wylie, Ernest Miller II; Xu, Ning
This report covers the FY 16 effort for the HPLC-ID-ICP-MS methodology 1) sub-method validation for the group I&II elements, 2) sub-method stood-up and validation for REE, 3) sub-method development for the transition element, and 4) completion of a comprehensive SOP for three families of elements.
Garcia-Perez, Isabel; Angulo, Santiago; Utzinger, Jürg; Holmes, Elaine; Legido-Quigley, Cristina; Barbas, Coral
2010-07-01
Metabonomic and metabolomic studies are increasingly utilized for biomarker identification in different fields, including biology of infection. The confluence of improved analytical platforms and the availability of powerful multivariate analysis software have rendered the multiparameter profiles generated by these omics platforms a user-friendly alternative to the established analysis methods where the quality and practice of a procedure is well defined. However, unlike traditional assays, validation methods for these new multivariate profiling tools have yet to be established. We propose a validation for models obtained by CE fingerprinting of urine from mice infected with the blood fluke Schistosoma mansoni. We have analysed urine samples from two sets of mice infected in an inter-laboratory experiment where different infection methods and animal husbandry procedures were employed in order to establish the core biological response to a S. mansoni infection. CE data were analysed using principal component analysis. Validation of the scores consisted of permutation scrambling (100 repetitions) and a manual validation method, using a third of the samples (not included in the model) as a test or prediction set. The validation yielded 100% specificity and 100% sensitivity, demonstrating the robustness of these models with respect to deciphering metabolic perturbations in the mouse due to a S. mansoni infection. A total of 20 metabolites across the two experiments were identified that significantly discriminated between S. mansoni-infected and noninfected control samples. Only one of these metabolites, allantoin, was identified as manifesting different behaviour in the two experiments. This study shows the reproducibility of CE-based metabolic profiling methods for disease characterization and screening and highlights the importance of much needed validation strategies in the emerging field of metabolomics.
Consensus methods: review of original methods and their main alternatives used in public health
Bourrée, Fanny; Michel, Philippe; Salmi, Louis Rachid
2008-01-01
Summary Background Consensus-based studies are increasingly used as decision-making methods, for they have lower production cost than other methods (observation, experimentation, modelling) and provide results more rapidly. The objective of this paper is to describe the principles and methods of the four main methods, Delphi, nominal group, consensus development conference and RAND/UCLA, their use as it appears in peer-reviewed publications and validation studies published in the healthcare literature. Methods A bibliographic search was performed in Pubmed/MEDLINE, Banque de Données Santé Publique (BDSP), The Cochrane Library, Pascal and Francis. Keywords, headings and qualifiers corresponding to a list of terms and expressions related to the consensus methods were searched in the thesauri, and used in the literature search. A search with the same terms and expressions was performed on Internet using the website Google Scholar. Results All methods, precisely described in the literature, are based on common basic principles such as definition of subject, selection of experts, and direct or remote interaction processes. They sometimes use quantitative assessment for ranking items. Numerous variants of these methods have been described. Few validation studies have been implemented. Not implementing these basic principles and failing to describe the methods used to reach the consensus were both frequent reasons contributing to raise suspicion regarding the validity of consensus methods. Conclusion When it is applied to a new domain with important consequences in terms of decision making, a consensus method should be first validated. PMID:19013039
NASA Technical Reports Server (NTRS)
Wanthal, Steven; Schaefer, Joseph; Justusson, Brian; Hyder, Imran; Engelstad, Stephen; Rose, Cheryl
2017-01-01
The Advanced Composites Consortium is a US Government/Industry partnership supporting technologies to enable timeline and cost reduction in the development of certified composite aerospace structures. A key component of the consortium's approach is the development and validation of improved progressive damage and failure analysis methods for composite structures. These methods will enable increased use of simulations in design trade studies and detailed design development, and thereby enable more targeted physical test programs to validate designs. To accomplish this goal with confidence, a rigorous verification and validation process was developed. The process was used to evaluate analysis methods and associated implementation requirements to ensure calculation accuracy and to gage predictability for composite failure modes of interest. This paper introduces the verification and validation process developed by the consortium during the Phase I effort of the Advanced Composites Project. Specific structural failure modes of interest are first identified, and a subset of standard composite test articles are proposed to interrogate a progressive damage analysis method's ability to predict each failure mode of interest. Test articles are designed to capture the underlying composite material constitutive response as well as the interaction of failure modes representing typical failure patterns observed in aerospace structures.
Chen, Po-Yu
2014-01-01
The validness of the expiration dates (validity period) that manufacturers provide on food product labels is a crucial food safety problem. Governments must study how to use their authority by implementing fair awards and punishments to prompt manufacturers into adopting rigorous considerations, such as the effect of adopting new storage methods for extending product validity periods on expected costs. Assuming that a manufacturer sells fresh food or drugs, this manufacturer must respond to current stochastic demands at each unit of time to determine the purchase amount of products for sale. If this decision maker is capable and an opportunity arises, new packaging methods (e.g., aluminum foil packaging, vacuum packaging, high-temperature sterilization after glass packaging, or packaging with various degrees of dryness) or storage methods (i.e., adding desiccants or various antioxidants) can be chosen to extend the validity periods of products. To minimize expected costs, this decision maker must be aware of the processing costs of new storage methods, inventory standards, inventory cycle lengths, and changes in relationships between factors such as stochastic demand functions in a cycle. Based on these changes in relationships, this study established a mathematical model as a basis for discussing the aforementioned topics.
NASA Astrophysics Data System (ADS)
Eschenbach, Wolfram; Budziak, Dörte; Elbracht, Jörg; Höper, Heinrich; Krienen, Lisa; Kunkel, Ralf; Meyer, Knut; Well, Reinhard; Wendland, Frank
2018-06-01
Valid models for estimating nitrate emissions from agriculture to groundwater are an indispensable forecasting tool. A major challenge for model validation is the spatial and temporal inconsistency between data from groundwater monitoring points and modelled nitrate inputs into groundwater, and the fact that many existing groundwater monitoring wells cannot be used for validation. With the help of the N2/Ar-method, groundwater monitoring wells in areas with reduced groundwater can now be used for model validation. For this purpose, 484 groundwater monitoring wells were sampled in Lower Saxony. For the first time, modelled potential nitrate concentrations in groundwater recharge (from the DENUZ model) were compared with nitrate input concentrations, which were calculated using the N2/Ar method. The results show a good agreement between both methods for glacial outwash plains and moraine deposits. Although the nitrate degradation processes in groundwater and soil merge seamlessly in areas with a shallow groundwater table, the DENUZ model only calculates denitrification in the soil zone. The DENUZ model thus predicts 27% higher nitrate emissions into the groundwater than the N2/Ar method in such areas. To account for high temporal and spatial variability of nitrate emissions into groundwater, a large number of groundwater monitoring points must be investigated for model validation.
Takahashi, Renata Ferreira; Gryschek, Anna Luíza F P L; Izumi Nichiata, Lúcia Yasuko; Lacerda, Rúbia Aparecida; Ciosak, Suely Itsuko; Gir, Elucir; Padoveze, Maria Clara
2010-05-01
There is growing demand for the adoption of qualification systems for health care practices. This study is aimed at describing the development and validation of indicators for evaluation of biologic occupational risk control programs. The study involved 3 stages: (1) setting up a research team, (2) development of indicators, and (3) validation of the indicators by a team of specialists recruited to validate each attribute of the developed indicators. The content validation method was used for the validation, and a psychometric scale was developed for the specialists' assessment. A consensus technique was used, and every attribute that obtained a Content Validity Index of at least 0.75 was approved. Eight indicators were developed for the evaluation of the biologic occupational risk prevention program, with emphasis on accidents caused by sharp instruments and occupational tuberculosis prevention. The indicators included evaluation of the structure, process, and results at the prevention and biologic risk control levels. The majority of indicators achieved a favorable consensus regarding all validated attributes. The developed indicators were considered validated, and the method used for construction and validation proved to be effective. Copyright (c) 2010 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
Investigation of a Sybr-Green-Based Method to Validate DNA Sequences for DNA Computing
2005-05-01
OF A SYBR-GREEN-BASED METHOD TO VALIDATE DNA SEQUENCES FOR DNA COMPUTING 6. AUTHOR(S) Wendy Pogozelski, Salvatore Priore, Matthew Bernard ...simulated annealing. Biochemistry, 35, 14077-14089. 15 Pogozelski, W.K., Bernard , M.P. and Macula, A. (2004) DNA code validation using...and Clark, B.F.C. (eds) In RNA Biochemistry and Biotechnology, NATO ASI Series, Kluwer Academic Publishers. Zucker, M. and Stiegler , P. (1981
Validating for Use and Interpretation: A Mixed Methods Contribution Illustrated
ERIC Educational Resources Information Center
Morell, Linda; Tan, Rachael Jin Bee
2009-01-01
Researchers in the areas of psychology and education strive to understand the intersections among validity, educational measurement, and cognitive theory. Guided by a mixed model conceptual framework, this study investigates how respondents' opinions inform the validation argument. Validity evidence for a science assessment was collected through…
ERIC Educational Resources Information Center
Dirlikov, Benjamin; Younes, Laurent; Nebel, Mary Beth; Martinelli, Mary Katherine; Tiedemann, Alyssa Nicole; Koch, Carolyn A.; Fiorilli, Diana; Bastian, Amy J.; Denckla, Martha Bridge; Miller, Michael I.; Mostofsky, Stewart H.
2017-01-01
This study presents construct validity for a novel automated morphometric and kinematic handwriting assessment, including (1) convergent validity, establishing reliability of automated measures with traditional manual-derived Minnesota Handwriting Assessment (MHA), and (2) discriminant validity, establishing that the automated methods distinguish…
Formal verification and testing: An integrated approach to validating Ada programs
NASA Technical Reports Server (NTRS)
Cohen, Norman H.
1986-01-01
An integrated set of tools called a validation environment is proposed to support the validation of Ada programs by a combination of methods. A Modular Ada Validation Environment (MAVEN) is described which proposes a context in which formal verification can fit into the industrial development of Ada software.
Adolescent Domain Screening Inventory-Short Form: Development and Initial Validation
ERIC Educational Resources Information Center
Corrigan, Matthew J.
2017-01-01
This study sought to develop a short version of the ADSI, and investigate its psychometric properties. Methods: This is a secondary analysis. Analysis to determine the Cronbach's Alpha, correlations to determine concurrent criterion validity and known instrument validity and a logistic regression to determine predictive validity were conducted.…
Initial Reliability and Validity of the Perceived Social Competence Scale
ERIC Educational Resources Information Center
Anderson-Butcher, Dawn; Iachini, Aidyn L.; Amorose, Anthony J.
2008-01-01
Objective: This study describes the development and validation of a perceived social competence scale that social workers can easily use to assess children's and youth's social competence. Method: Exploratory and confirmatory factor analyses were conducted on a calibration and a cross-validation sample of youth. Predictive validity was also…
Coates, Jennifer; Colaiezzi, Brooke; Fiedler, John L; Wirth, James; Lividini, Keith; Rogers, Beatrice
2012-09-01
Dietary assessment data are essential for designing, monitoring, and evaluating food fortification and other food-based nutrition programs. Planners and managers must understand the validity, usefulness, and cost tradeoffs of employing alternative dietary assessment methods, but little guidance exists. To identify and apply criteria to assess the tradeoffs of using alternative dietary methods for meeting fortification programming needs. Twenty-five semistructured expert interviews were conducted and literature was reviewed for information on the validity, usefulness, and cost of using 24-hour recalls, Food Frequency Questionnaires/Fortification Rapid Assessment Tool (FFQ/FRAT), Food Balance Sheets (FBS), and Household Consumption and Expenditures Surveys (HCES) for program stage-specific information needs. Criteria were developed and applied to construct relative rankings of the four methods. Needs assessment: HCES offers the greatest suitability at the lowest cost for estimating the risk of inadequate intakes, but relative to 24-hour recall compromises validity. HCES should be used to identify vehicles and to estimate coverage and likely impact due to its low cost and moderate-to-high validity. Baseline assessment: 24-hour recall should be applied using a representative sample. Monitoring: A simple, low-cost FFQ can be used to monitor coverage. Impact evaluation: 24-hour recall should be used to assess changes in nutrient intakes. FBS have low validity relative to other methods for all programmatic purposes. Each dietary assessment method has strengths and weaknesses that vary by context and purpose. Method selection must be driven by the program's data needs, the suitability of the methods for the purpose, and a clear understanding of the tradeoffs involved.
Validation and Verification (V and V) Testing on Midscale Flame Resistant (FR) Test Method
2016-12-16
Method for Evaluation of Flame Resistant Clothing for Protection against Fire Simulations Using an Instrumented Manikin. Validation and...complement (not replace) the capabilities of the ASTM F1930 Standard Test Method for Evaluation of Flame Resistant Clothing for Protection against Fire ...Engineering Center (NSRDEC) to complement the ASTM F1930 Standard Test Method for Evaluation of Flame Resistant Clothing for Protection against Fire
Concept Development for Future Domains: A New Method of Knowledge Elicitation
2005-06-01
Procedure: U.S. Army Research Institute for the Behavioral and Social Sciences (ARI) examined methods to generate, refine, test , and validate new...generate, elaborate, refine, describe, test , and validate new Future Force concepts relating to doctrine, tactics, techniques, procedures, unit and team...System (Harvey, 1993), and the Job Element Method (Primoff & Eyde , 1988). Figure 1 provides a more comprehensive list of task analytic methods. Please see
Szerkus, Oliwia; Struck-Lewicka, Wiktoria; Kordalewska, Marta; Bartosińska, Ewa; Bujak, Renata; Borsuk, Agnieszka; Bienert, Agnieszka; Bartkowska-Śniatkowska, Alicja; Warzybok, Justyna; Wiczling, Paweł; Nasal, Antoni; Kaliszan, Roman; Markuszewski, Michał Jan; Siluk, Danuta
2017-02-01
The purpose of this work was to develop and validate a rapid and robust LC-MS/MS method for the determination of dexmedetomidine (DEX) in plasma, suitable for analysis of a large number of samples. Systematic approach, Design of Experiments, was applied to optimize ESI source parameters and to evaluate method robustness, therefore, a rapid, stable and cost-effective assay was developed. The method was validated according to US FDA guidelines. LLOQ was determined at 5 pg/ml. The assay was linear over the examined concentration range (5-2500 pg/ml), Results: Experimental design approach was applied for optimization of ESI source parameters and evaluation of method robustness. The method was validated according to the US FDA guidelines. LLOQ was determined at 5 pg/ml. The assay was linear over the examined concentration range (R 2 > 0.98). The accuracies, intra- and interday precisions were less than 15%. The stability data confirmed reliable behavior of DEX under tested conditions. Application of Design of Experiments approach allowed for fast and efficient analytical method development and validation as well as for reduced usage of chemicals necessary for regular method optimization. The proposed technique was applied to determination of DEX pharmacokinetics in pediatric patients undergoing long-term sedation in the intensive care unit.
Hickey, Graeme L; Blackstone, Eugene H
2016-08-01
Clinical risk-prediction models serve an important role in healthcare. They are used for clinical decision-making and measuring the performance of healthcare providers. To establish confidence in a model, external model validation is imperative. When designing such an external model validation study, thought must be given to patient selection, risk factor and outcome definitions, missing data, and the transparent reporting of the analysis. In addition, there are a number of statistical methods available for external model validation. Execution of a rigorous external validation study rests in proper study design, application of suitable statistical methods, and transparent reporting. Copyright © 2016 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.
Validation of asthma recording in electronic health records: a systematic review
Nissen, Francis; Quint, Jennifer K; Wilkinson, Samantha; Mullerova, Hana; Smeeth, Liam; Douglas, Ian J
2017-01-01
Objective To describe the methods used to validate asthma diagnoses in electronic health records and summarize the results of the validation studies. Background Electronic health records are increasingly being used for research on asthma to inform health services and health policy. Validation of the recording of asthma diagnoses in electronic health records is essential to use these databases for credible epidemiological asthma research. Methods We searched EMBASE and MEDLINE databases for studies that validated asthma diagnoses detected in electronic health records up to October 2016. Two reviewers independently assessed the full text against the predetermined inclusion criteria. Key data including author, year, data source, case definitions, reference standard, and validation statistics (including sensitivity, specificity, positive predictive value [PPV], and negative predictive value [NPV]) were summarized in two tables. Results Thirteen studies met the inclusion criteria. Most studies demonstrated a high validity using at least one case definition (PPV >80%). Ten studies used a manual validation as the reference standard; each had at least one case definition with a PPV of at least 63%, up to 100%. We also found two studies using a second independent database to validate asthma diagnoses. The PPVs of the best performing case definitions ranged from 46% to 58%. We found one study which used a questionnaire as the reference standard to validate a database case definition; the PPV of the case definition algorithm in this study was 89%. Conclusion Attaining high PPVs (>80%) is possible using each of the discussed validation methods. Identifying asthma cases in electronic health records is possible with high sensitivity, specificity or PPV, by combining multiple data sources, or by focusing on specific test measures. Studies testing a range of case definitions show wide variation in the validity of each definition, suggesting this may be important for obtaining asthma definitions with optimal validity. PMID:29238227
Klussmann, Andre; Liebers, Falk; Brandstädt, Felix; Schust, Marianne; Serafin, Patrick; Schäfer, Andreas; Gebhardt, Hansjürgen; Hartmann, Bernd; Steinberg, Ulf
2017-08-21
The impact of work-related musculoskeletal disorders is considerable. The assessment of work tasks with physical workloads is crucial to estimate the work-related health risks of exposed employees. Three key indicator methods are available for risk assessment regarding manual lifting, holding and carrying of loads; manual pulling and pushing of loads; and manual handling operations. Three further KIMs for risk assessment regarding whole-body forces, awkward body postures and body movement have been developed de novo. In addition, the development of a newly drafted combined method for mixed exposures is planned. All methods will be validated regarding face validity, reliability, convergent validity, criterion validity and further aspects of utility under practical conditions. As part of the joint project MEGAPHYS (multilevel risk assessment of physical workloads), a mixed-methods study is being designed for the validation of KIMs and conducted in companies of different sizes and branches in Germany. Workplaces are documented and analysed by observations, applying KIMs, interviews and assessment of environmental conditions. Furthermore, a survey among the employees at the respective workplaces takes place with standardised questionnaires, interviews and physical examinations. It is intended to include 1200 employees at 120 different workplaces. For analysis of the quality criteria, recommendations of the COSMIN checklist (COnsensus-based Standards for the selection of health Measurement INstruments) will be taken into account. The study was planned and conducted in accordance with the German Medical Professional Code and the Declaration of Helsinki as well as the German Federal Data Protection Act. The design of the study was approved by ethics committees. We intend to publish the validated KIMs in 2018. Results will be published in peer-reviewed journals, presented at international meetings and disseminated to actual users for practical application. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Austin, Peter C.; van Klaveren, David; Vergouwe, Yvonne; Nieboer, Daan; Lee, Douglas S.; Steyerberg, Ewout W.
2017-01-01
Objective Validation of clinical prediction models traditionally refers to the assessment of model performance in new patients. We studied different approaches to geographic and temporal validation in the setting of multicenter data from two time periods. Study Design and Setting We illustrated different analytic methods for validation using a sample of 14,857 patients hospitalized with heart failure at 90 hospitals in two distinct time periods. Bootstrap resampling was used to assess internal validity. Meta-analytic methods were used to assess geographic transportability. Each hospital was used once as a validation sample, with the remaining hospitals used for model derivation. Hospital-specific estimates of discrimination (c-statistic) and calibration (calibration intercepts and slopes) were pooled using random effects meta-analysis methods. I2 statistics and prediction interval width quantified geographic transportability. Temporal transportability was assessed using patients from the earlier period for model derivation and patients from the later period for model validation. Results Estimates of reproducibility, pooled hospital-specific performance, and temporal transportability were on average very similar, with c-statistics of 0.75. Between-hospital variation was moderate according to I2 statistics and prediction intervals for c-statistics. Conclusion This study illustrates how performance of prediction models can be assessed in settings with multicenter data at different time periods. PMID:27262237
Barrero, Lope H; Katz, Jeffrey N; Dennerlein, Jack T
2012-01-01
Objectives To describe the relation of the measured validity of self-reported mechanical demands (self-reports) with the quality of validity assessments and the variability of the assessed exposure in the study population. Methods We searched for original articles, published between 1990 and 2008, reporting the validity of self-reports in three major databases: EBSCOhost, Web of Science, and PubMed. Identified assessments were classified by methodological characteristics (eg, type of self-report and reference method) and exposure dimension was measured. We also classified assessments by the degree of comparability between the self-report and the employed reference method, and the variability of the assessed exposure in the study population. Finally, we examined the association of the published validity (r) with this degree of comparability, as well as with the variability of the exposure variable in the study population. Results Of the 490 assessments identified, 75% used observation-based reference measures and 55% tested self-reports of posture duration and movement frequency. Frequently, validity studies did not report demographic information (eg, education, age, and gender distribution). Among assessments reporting correlations as a measure of validity, studies with a better match between the self-report and the reference method, and studies conducted in more heterogeneous populations tended to report higher correlations [odds ratio (OR) 2.03, 95% confidence interval (95% CI) 0.89–4.65 and OR 1.60, 95% CI 0.96–2.61, respectively]. Conclusions The reported data support the hypothesis that validity depends on study-specific factors often not examined. Experimentally manipulating the testing setting could lead to a better understanding of the capabilities and limitations of self-reported information. PMID:19562235
Development and Validation of New Discriminative Dissolution Method for Carvedilol Tablets
Raju, V.; Murthy, K. V. R.
2011-01-01
The objective of the present study was to develop and validate a discriminative dissolution method for evaluation of carvedilol tablets. Different conditions such as type of dissolution medium, volume of dissolution medium and rotation speed of paddle were evaluated. The best in vitro dissolution profile was obtained using Apparatus II (paddle), 50 rpm, 900 ml of pH 6.8 phosphate buffer as dissolution medium. The drug release was evaluated by high-performance liquid chromatographic method. The dissolution method was validated according to current ICH and FDA guidelines using parameters such as the specificity, accuracy, precision and stability were evaluated and obtained results were within the acceptable range. The comparison of the obtained dissolution profiles of three different products were investigated using ANOVA-based, model-dependent and model-independent methods, results showed that there is significant difference between the products. The dissolution test developed and validated was adequate for its higher discriminative capacity in differentiating the release characteristics of the products tested and could be applied for development and quality control of carvedilol tablets. PMID:22923865
NASA Astrophysics Data System (ADS)
Yugatama, A.; Rohmani, S.; Dewangga, A.
2018-03-01
Atorvastatin is the primary choice for dyslipidemia treatment. Due to patent expiration of atorvastatin, the pharmaceutical industry makes copy of the drug. Therefore, the development methods for tablet quality tests involving atorvastatin concentration on tablets needs to be performed. The purpose of this research was to develop and validate the simple atorvastatin tablet analytical method by HPLC. HPLC system used in this experiment consisted of column Cosmosil C18 (150 x 4,6 mm, 5 µm) as the stationary reverse phase chomatography, a mixture of methanol-water at pH 3 (80:20 v/v) as the mobile phase, flow rate of 1 mL/min, and UV detector at wavelength of 245 nm. Validation methods were including: selectivity, linearity, accuracy, precision, limit of detection (LOD), and limit of quantitation (LOQ). The results of this study indicate that the developed method had good validation including selectivity, linearity, accuracy, precision, LOD, and LOQ for analysis of atorvastatin tablet content. LOD and LOQ were 0.2 and 0.7 ng/mL, and the linearity range were 20 - 120 ng/mL.
Center of pressure based segment inertial parameters validation
Rezzoug, Nasser; Gorce, Philippe; Isableu, Brice; Venture, Gentiane
2017-01-01
By proposing efficient methods for estimating Body Segment Inertial Parameters’ (BSIP) estimation and validating them with a force plate, it is possible to improve the inverse dynamic computations that are necessary in multiple research areas. Until today a variety of studies have been conducted to improve BSIP estimation but to our knowledge a real validation has never been completely successful. In this paper, we propose a validation method using both kinematic and kinetic parameters (contact forces) gathered from optical motion capture system and a force plate respectively. To compare BSIPs, we used the measured contact forces (Force plate) as the ground truth, and reconstructed the displacements of the Center of Pressure (COP) using inverse dynamics from two different estimation techniques. Only minor differences were seen when comparing the estimated segment masses. Their influence on the COP computation however is large and the results show very distinguishable patterns of the COP movements. Improving BSIP techniques is crucial and deviation from the estimations can actually result in large errors. This method could be used as a tool to validate BSIP estimation techniques. An advantage of this approach is that it facilitates the comparison between BSIP estimation methods and more specifically it shows the accuracy of those parameters. PMID:28662090
Dehouck, P; Vander Heyden, Y; Smeyers-Verbeke, J; Massart, D L; Marini, R D; Chiap, P; Hubert, Ph; Crommen, J; Van de Wauw, W; De Beer, J; Cox, R; Mathieu, G; Reepmeyer, J C; Voigt, B; Estevenon, O; Nicolas, A; Van Schepdael, A; Adams, E; Hoogmartens, J
2003-08-22
Erythromycin is a mixture of macrolide antibiotics produced by Saccharopolyspora erythreas during fermentation. A new method for the analysis of erythromycin by liquid chromatography has previously been developed. It makes use of an Astec C18 polymeric column. After validation in one laboratory, the method was now validated in an interlaboratory study. Validation studies are commonly used to test the fitness of the analytical method prior to its use for routine quality testing. The data derived in the interlaboratory study can be used to make an uncertainty statement as well. The relationship between validation and uncertainty statement is not clear for many analysts and there is a need to show how the existing data, derived during validation, can be used in practice. Eight laboratories participated in this interlaboratory study. The set-up allowed the determination of the repeatability variance, s(2)r and the between-laboratory variance, s(2)L. Combination of s(2)r and s(2)L results in the reproducibility variance s(2)R. It has been shown how these data can be used in future by a single laboratory that wants to make an uncertainty statement concerning the same analysis.
NASA Astrophysics Data System (ADS)
Kuschenerus, Mieke; Cullen, Robert
2016-08-01
To ensure reliability and precision of wave height estimates for future satellite altimetry missions such as Sentinel 6, reliable parameter retrieval algorithms that can extract significant wave heights up to 20 m have to be established. The retrieved parameters, i.e. the retrieval methods need to be validated extensively on a wide range of possible significant wave heights. Although current missions require wave height retrievals up to 20 m, there is little evidence of systematic validation of parameter retrieval methods for sea states with wave heights above 10 m. This paper provides a definition of a set of simulated sea states with significant wave height up to 20 m, that allow simulation of radar altimeter response echoes for extreme sea states in SAR and low resolution mode. The simulated radar responses are used to derive significant wave height estimates, which can be compared with the initial models, allowing precision estimations of the applied parameter retrieval methods. Thus we establish a validation method for significant wave height retrieval for sea states causing high significant wave heights, to allow improved understanding and planning of future satellite altimetry mission validation.
Validating Remotely Sensed Land Surface Evapotranspiration Based on Multi-scale Field Measurements
NASA Astrophysics Data System (ADS)
Jia, Z.; Liu, S.; Ziwei, X.; Liang, S.
2012-12-01
The land surface evapotranspiration plays an important role in the surface energy balance and the water cycle. There have been significant technical and theoretical advances in our knowledge of evapotranspiration over the past two decades. Acquisition of the temporally and spatially continuous distribution of evapotranspiration using remote sensing technology has attracted the widespread attention of researchers and managers. However, remote sensing technology still has many uncertainties coming from model mechanism, model inputs, parameterization schemes, and scaling issue in the regional estimation. Achieving remotely sensed evapotranspiration (RS_ET) with confident certainty is required but difficult. As a result, it is indispensable to develop the validation methods to quantitatively assess the accuracy and error sources of the regional RS_ET estimations. This study proposes an innovative validation method based on multi-scale evapotranspiration acquired from field measurements, with the validation results including the accuracy assessment, error source analysis, and uncertainty analysis of the validation process. It is a potentially useful approach to evaluate the accuracy and analyze the spatio-temporal properties of RS_ET at both the basin and local scales, and is appropriate to validate RS_ET in diverse resolutions at different time-scales. An independent RS_ET validation using this method was presented over the Hai River Basin, China in 2002-2009 as a case study. Validation at the basin scale showed good agreements between the 1 km annual RS_ET and the validation data such as the water balanced evapotranspiration, MODIS evapotranspiration products, precipitation, and landuse types. Validation at the local scale also had good results for monthly, daily RS_ET at 30 m and 1 km resolutions, comparing to the multi-scale evapotranspiration measurements from the EC and LAS, respectively, with the footprint model over three typical landscapes. Although some validation experiments demonstrated that the models yield accurate estimates at flux measurement sites, the question remains whether they are performing well over the broader landscape. Moreover, a large number of RS_ET products have been released in recent years. Thus, we also pay attention to the cross-validation method of RS_ET derived from multi-source models. "The Multi-scale Observation Experiment on Evapotranspiration over Heterogeneous Land Surfaces: Flux Observation Matrix" campaign is carried out at the middle reaches of the Heihe River Basin, China in 2012. Flux measurements from an observation matrix composed of 22 EC and 4 LAS are acquired to investigate the cross-validation of multi-source models over different landscapes. In this case, six remote sensing models, including the empirical statistical model, the one-source and two-source models, the Penman-Monteith equation based model, the Priestley-Taylor equation based model, and the complementary relationship based model, are used to perform an intercomparison. All the results from the two cases of RS_ET validation showed that the proposed validation methods are reasonable and feasible.
TMATS/ IHAL/ DDML Schema Validation
2017-02-01
task was to create a method for performing IRIG eXtensible Markup Language (XML) schema validation. As opposed to XML instance document validation...TMATS / IHAL / DDML Schema Validation, RCC 126-17, February 2017 vii Acronyms DDML Data Display Markup Language HUD heads-up display iNET...system XML eXtensible Markup Language TMATS / IHAL / DDML Schema Validation, RCC 126-17, February 2017 viii This page intentionally left blank
USDA-ARS?s Scientific Manuscript database
A collaborative validation study was performed to evaluate the performance of a new U.S. Food and Drug Administration method developed for detection of the protozoan parasite, Cyclospora cayetanensis, on cilantro and raspberries. The method includes a sample preparation step in which oocysts are re...
CFD Analysis of the SBXC Glider Airframe
2016-06-01
mathematically on finite element methods. To validate and verify the methodology developed, a mathematical comparison was made with the previous research data...greater than 15 m/s. 14. SUBJECT TERMS finite element method, computational fluid dynamics, Y Plus, mesh element quality, aerodynamic data, fluid...based mathematically on finite element methods. To validate and verify the methodology developed, a mathematical comparison was made with the
Determination of vitamin C in foods: current state of method validation.
Spínola, Vítor; Llorent-Martínez, Eulogio J; Castilho, Paula C
2014-11-21
Vitamin C is one of the most important vitamins, so reliable information about its content in foodstuffs is a concern to both consumers and quality control agencies. However, the heterogeneity of food matrixes and the potential degradation of this vitamin during its analysis create enormous challenges. This review addresses the development and validation of high-performance liquid chromatography methods for vitamin C analysis in food commodities, during the period 2000-2014. The main characteristics of vitamin C are mentioned, along with the strategies adopted by most authors during sample preparation (freezing and acidification) to avoid vitamin oxidation. After that, the advantages and handicaps of different analytical methods are discussed. Finally, the main aspects concerning method validation for vitamin C analysis are critically discussed. Parameters such as selectivity, linearity, limit of quantification, and accuracy were studied by most authors. Recovery experiments during accuracy evaluation were in general satisfactory, with usual values between 81 and 109%. However, few methods considered vitamin C stability during the analytical process, and the study of the precision was not always clear or complete. Potential future improvements regarding proper method validation are indicated to conclude this review. Copyright © 2014. Published by Elsevier B.V.
Measurement of Harm Outcomes in Older Adults after Hospital Discharge: Reliability and Validity
Douglas, Alison; Letts, Lori; Eva, Kevin; Richardson, Julie
2012-01-01
Objectives. Defining and validating a measure of safety contributes to further validation of clinical measures. The objective was to define and examine the psychometric properties of the outcome “incidents of harm.” Methods. The Incident of Harm Caregiver Questionnaire was administered to caregivers of older adults discharged from hospital by telephone. Caregivers completed daily logs for one month and medical charts were examined. Results. Test-retest reliability (n = 38) was high for the occurrence of an incident of harm (yes/no; kappa = 1.0) and the type of incident (agreement = 100%). Validation against daily logs found no disagreement regarding occurrence or types of incidents. Validation with medical charts found no disagreement regarding incident occurrence and disagreement in half regarding incident type. Discussion. The data support the Incident of Harm Caregiver Questionnaire as a reliable and valid estimation of incidents for this sample and are important to researchers as a method to measure safety when validating clinical measures. PMID:22649728
What is the best method for assessing lower limb force-velocity relationship?
Giroux, C; Rabita, G; Chollet, D; Guilhem, G
2015-02-01
This study determined the concurrent validity and reliability of force, velocity and power measurements provided by accelerometry, linear position transducer and Samozino's methods, during loaded squat jumps. 17 subjects performed squat jumps on 2 separate occasions in 7 loading conditions (0-60% of the maximal concentric load). Force, velocity and power patterns were averaged over the push-off phase using accelerometry, linear position transducer and a method based on key positions measurements during squat jump, and compared to force plate measurements. Concurrent validity analyses indicated very good agreement with the reference method (CV=6.4-14.5%). Force, velocity and power patterns comparison confirmed the agreement with slight differences for high-velocity movements. The validity of measurements was equivalent for all tested methods (r=0.87-0.98). Bland-Altman plots showed a lower agreement for velocity and power compared to force. Mean force, velocity and power were reliable for all methods (ICC=0.84-0.99), especially for Samozino's method (CV=2.7-8.6%). Our findings showed that present methods are valid and reliable in different loading conditions and permit between-session comparisons and characterization of training-induced effects. While linear position transducer and accelerometer allow for examining the whole time-course of kinetic patterns, Samozino's method benefits from a better reliability and ease of processing. © Georg Thieme Verlag KG Stuttgart · New York.
The use of National Weather Service Data to Compute the Dose to the MEOI.
Vickers, Linda
2018-05-01
The Turner method is the "benchmark method" for computing the stability class that is used to compute the X/Q (s m). The Turner method should be used to ascertain the validity of X/Q results determined by other methods. This paper used site-specific meteorological data obtained from the National Weather Service. The Turner method described herein is simple, quick, accurate, and transparent because all of the data, calculations, and results are visible for verification and validation with published literature.
Validity of a Measure of Assertiveness
ERIC Educational Resources Information Center
Galassi, John P.; Galassi, Merna D.
1974-01-01
This study was concerned with further validation of a measure of assertiveness. Concurrent validity was established for the College Self-Expression Scale using the method of contrasted groups and through correlations of self-and judges' ratings of assertiveness. (Author)
Implementing an X-ray validation pipeline for the Protein Data Bank
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gore, Swanand; Velankar, Sameer; Kleywegt, Gerard J., E-mail: gerard@ebi.ac.uk
2012-04-01
The implementation of a validation pipeline, based on community recommendations, for future depositions of X-ray crystal structures in the Protein Data Bank is described. There is an increasing realisation that the quality of the biomacromolecular structures deposited in the Protein Data Bank (PDB) archive needs to be assessed critically using established and powerful validation methods. The Worldwide Protein Data Bank (wwPDB) organization has convened several Validation Task Forces (VTFs) to advise on the methods and standards that should be used to validate all of the entries already in the PDB as well as all structures that will be deposited inmore » the future. The recommendations of the X-ray VTF are currently being implemented in a software pipeline. Here, ongoing work on this pipeline is briefly described as well as ways in which validation-related information could be presented to users of structural data.« less
Validity evidence based on test content.
Sireci, Stephen; Faulkner-Bond, Molly
2014-01-01
Validity evidence based on test content is one of the five forms of validity evidence stipulated in the Standards for Educational and Psychological Testing developed by the American Educational Research Association, American Psychological Association, and National Council on Measurement in Education. In this paper, we describe the logic and theory underlying such evidence and describe traditional and modern methods for gathering and analyzing content validity data. A comprehensive review of the literature and of the aforementioned Standards is presented. For educational tests and other assessments targeting knowledge and skill possessed by examinees, validity evidence based on test content is necessary for building a validity argument to support the use of a test for a particular purpose. By following the methods described in this article, practitioners have a wide arsenal of tools available for determining how well the content of an assessment is congruent with and appropriate for the specific testing purposes.
Validation of Multilevel Constructs: Validation Methods and Empirical Findings for the EDI
ERIC Educational Resources Information Center
Forer, Barry; Zumbo, Bruno D.
2011-01-01
The purposes of this paper are to highlight the foundations of multilevel construct validation, describe two methodological approaches and associated analytic techniques, and then apply these approaches and techniques to the multilevel construct validation of a widely-used school readiness measure called the Early Development Instrument (EDI;…
NASA Astrophysics Data System (ADS)
Ivanova, V.; Surleva, A.; Koleva, B.
2018-06-01
An ion chromatographic method for determination of fluoride, chloride, nitrate and sulphate in untreated and treated drinking waters was described. An automated 850 IC Professional, Metrohm system equipped with conductivity detector and Metrosep A Supp 7-250 (250 x 4 mm) column was used. The validation of the method was performed for simultaneous determination of all studied analytes and the results have showed that the validated method fits the requirements of the current water legislation. The main analytical characteristics were estimated for each of studied analytes: limits of detection, limits of quantification, working and linear ranges, repeatability and intermediate precision, recovery. The trueness of the method was estimated by analysis of certified reference material for soft drinking water. Recovery test was performed on spiked drinking water samples. An uncertainty was estimated. The method was applied for analysis of drinking waters before and after chlorination.
A review of MRI evaluation of demyelination in cuprizone murine model
NASA Astrophysics Data System (ADS)
Krutenkova, E.; Pan, E.; Khodanovich, M.
2015-11-01
The cuprizone mouse model of non-autoimmune demyelination reproduces some phenomena of multiple sclerosis and is appropriate for validation and specification of a new method of non-invasive diagnostics. In the review new data which are collected using the new MRI method are compared with one or more conventional MRI tools. Also the paper reviewed the validation of MRI approaches using histological or immunohistochemical methods. Luxol fast blue histological staining and myelin basic protein immunostaining is widespread. To improve the accuracy of non-invasive conventional MRI, multimodal scanning could be applied. The new quantitative MRI method of fast mapping of the macromolecular proton fraction is a reliable biomarker of myelin in the brain and can be used for research of demyelination in animals. To date, a validation of MPF method on the CPZ mouse model of demyelination is not performed, although this method is probably the best way to evaluate demyelination using MRI.
Sokoliess, Torsten; Köller, Gerhard
2005-06-01
A chiral capillary electrophoresis system allowing the determination of the enantiomeric purity of an investigational new drug was developed using a generic method development approach for basic analytes. The method was optimized in terms of type and concentration of both cyclodextrin (CD) and electrolyte, buffer pH, temperature, voltage, and rinsing procedure. Optimal chiral separation of the analyte was obtained using an electrolyte with 2.5% carboxymethyl-beta-CD in 25 mM NaH2PO4 (pH 4.0). Interchanging the inlet and outlet vials after each run improved the method's precision. To assure the method's suitability for the control of enantiomeric impurities in pharmaceutical quality control, its specificity, linearity, precision, accuracy, and robustness were validated according to the requirements of the International Conference on Harmonization. The usefulness of our generic method development approach for the validation of robustness was demonstrated.
Jacchia, Sara; Nardini, Elena; Bassani, Niccolò; Savini, Christian; Shim, Jung-Hyun; Trijatmiko, Kurniawan; Kreysa, Joachim; Mazzara, Marco
2015-05-27
This article describes the international validation of the quantitative real-time polymerase chain reaction (PCR) detection method for Golden Rice 2. The method consists of a taxon-specific assay amplifying a fragment of rice Phospholipase D α2 gene, and an event-specific assay designed on the 3' junction between transgenic insert and plant DNA. We validated the two assays independently, with absolute quantification, and in combination, with relative quantification, on DNA samples prepared in haploid genome equivalents. We assessed trueness, precision, efficiency, and linearity of the two assays, and the results demonstrate that both the assays independently assessed and the entire method fulfill European and international requirements for methods for genetically modified organism (GMO) testing, within the dynamic range tested. The homogeneity of the results of the collaborative trial between Europe and Asia is a good indicator of the robustness of the method.
Quantitative risk assessment is fraught with many uncertainties. The validity of the assumptions underlying the methods employed are often difficult to test or validate. Cancer risk assessment has generally employed either human epidemiological data from relatively high occupatio...
Ciceri, E; Recchia, S; Dossi, C; Yang, L; Sturgeon, R E
2008-01-15
The development and validation of a method for the determination of mercury in sediments using a sector field inductively coupled plasma mass spectrometer (SF-ICP-MS) for detection is described. The utilization of isotope dilution (ID) calibration is shown to solve analytical problems related to matrix composition. Mass bias is corrected using an internal mass bias correction technique, validated against the traditional standard bracketing method. The overall analytical protocol is validated against NRCC PACS-2 marine sediment CRM. The estimated limit of detection is 12ng/g. The proposed procedure was applied to the analysis of a real sediment core sampled to a depth of 160m in Lake Como, where Hg concentrations ranged from 66 to 750ng/g.
Koller, Ingrid; Levenson, Michael R.; Glück, Judith
2017-01-01
The valid measurement of latent constructs is crucial for psychological research. Here, we present a mixed-methods procedure for improving the precision of construct definitions, determining the content validity of items, evaluating the representativeness of items for the target construct, generating test items, and analyzing items on a theoretical basis. To illustrate the mixed-methods content-scaling-structure (CSS) procedure, we analyze the Adult Self-Transcendence Inventory, a self-report measure of wisdom (ASTI, Levenson et al., 2005). A content-validity analysis of the ASTI items was used as the basis of psychometric analyses using multidimensional item response models (N = 1215). We found that the new procedure produced important suggestions concerning five subdimensions of the ASTI that were not identifiable using exploratory methods. The study shows that the application of the suggested procedure leads to a deeper understanding of latent constructs. It also demonstrates the advantages of theory-based item analysis. PMID:28270777
Sghaier, Lilia; Cordella, Christophe B Y; Rutledge, Douglas N; Watiez, Mickaël; Breton, Sylvie; Sassiat, Patrick; Thiebaut, Didier; Vial, Jérôme
2016-05-01
Due to lipid oxidation, off-flavors, characterized by a fishy odor, are emitted during the heating of rapeseed oil in a fryer and affect the flavor of rapeseed oil even at low concentrations. Thus, there is a need for analytical methods to identify and quantify these products. To study the headspace composition of degraded rapeseed oil, and more specifically the compounds responsible for the fishy odor, a headspace trap gas chromatography with mass spectrometry method was developed and validated. Six volatile compounds formed during the degradation of rapeseed oil were quantified: 1-penten-3-one, (Z)-4-heptenal, hexanal, nonanal, (E,E)-heptadienal, and (E)-2-heptenal. Validation using accuracy profiles allowed us to determine the valid ranges of concentrations for each compound, with acceptance limits of 40% and tolerance limits of 80%. This method was then successfully applied to real samples of degraded oils. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Yang, Xing-Xin; Zhang, Xiao-Xia; Chang, Rui-Miao; Wang, Yan-Wei; Li, Xiao-Ni
2011-01-01
A simple and reliable high performance liquid chromatography (HPLC) method has been developed for the simultaneous quantification of five major bioactive components in ‘Shu-Jin-Zhi-Tong’ capsules (SJZTC), for the purposes of quality control of this commonly prescribed traditional Chinese medicine. Under the optimum conditions, excellent separation was achieved, and the assay was fully validated in terms of linearity, precision, repeatability, stability and accuracy. The validated method was applied successfully to the determination of the five compounds in SJZTC samples from different production batches. The HPLC method can be used as a valid analytical method to evaluate the intrinsic quality of SJZTC. PMID:29403711
Marwah, Ashok; Marwah, Padma; Lardy, Henry
2005-09-25
17alpha-Methyltestosterone (MT) is used to manipulate the gender of a variety of fish species. A high performance liquid chromatography (HPLC) internal standard method for the determination of 17alpha-methyltestosterone in fish feed using 3beta-methoxy-17beta-hydroxyandrost-5-en-7-one as internal standard (IS) has been developed. The method has been validated for the quantitation of MT in fish feed using 245 nm UV absorbance as the parent wavelength and 255 nm as a qualifier wavelength. The method was validated in the concentration range of 15.0-120 mg/kg of 17alpha-methyltestosterone in fish feed. Method was also found to be suitable for other feeds.
Iridology: A systematic review.
Ernst, E
1999-02-01
Iridologists claim to be able to diagnose medical conditions through abnormalities of pigmentation in the iris. This technique is popular in many countries. Therefore it is relevant to ask whether it is valid. To systematically review all interpretable tests of the validity of iridology as a diagnostic tool. DATA SOURCE AND EXTRACTION: Three independent literature searches were performed to identify all blinded tests. Data were extracted in a predefined, standardized fashion. Four case control studies were found. The majority of these investigations suggests that iridology is not a valid diagnostic method. The validity of iridology as a diagnostic tool is not supported by scientific evaluations. Patients and therapists should be discouraged from using this method.
NASA Astrophysics Data System (ADS)
Liu, Jia; Liu, Longli; Xue, Yong; Dong, Jing; Hu, Yingcui; Hill, Richard; Guang, Jie; Li, Chi
2017-01-01
Workflow for remote sensing quantitative retrieval is the ;bridge; between Grid services and Grid-enabled application of remote sensing quantitative retrieval. Workflow averts low-level implementation details of the Grid and hence enables users to focus on higher levels of application. The workflow for remote sensing quantitative retrieval plays an important role in remote sensing Grid and Cloud computing services, which can support the modelling, construction and implementation of large-scale complicated applications of remote sensing science. The validation of workflow is important in order to support the large-scale sophisticated scientific computation processes with enhanced performance and to minimize potential waste of time and resources. To research the semantic correctness of user-defined workflows, in this paper, we propose a workflow validation method based on tacit knowledge research in the remote sensing domain. We first discuss the remote sensing model and metadata. Through detailed analysis, we then discuss the method of extracting the domain tacit knowledge and expressing the knowledge with ontology. Additionally, we construct the domain ontology with Protégé. Through our experimental study, we verify the validity of this method in two ways, namely data source consistency error validation and parameters matching error validation.
Kang, Homan; Jeong, Sinyoung; Jo, Ahla; Chang, Hyejin; Yang, Jin-Kyoung; Jeong, Cheolhwan; Kyeong, San; Lee, Youn Woo; Samanta, Animesh; Maiti, Kaustabh Kumar; Cha, Myeong Geun; Kim, Taek-Keun; Lee, Sukmook; Jun, Bong-Hyun; Chang, Young-Tae; Chung, Junho; Lee, Ho-Young; Jeong, Dae Hong; Lee, Yoon-Sik
2018-02-01
Immunotargeting ability of antibodies may show significant difference between in vitro and in vivo. To select antibody leads with high affinity and specificity, it is necessary to perform in vivo validation of antibody candidates following in vitro antibody screening. Herein, a robust in vivo validation of anti-tetraspanin-8 antibody candidates against human colon cancer using ratiometric quantification method is reported. The validation is performed on a single mouse and analyzed by multiplexed surface-enhanced Raman scattering using ultrasensitive and near infrared (NIR)-active surface-enhanced resonance Raman scattering nanoprobes (NIR-SERRS dots). The NIR-SERRS dots are composed of NIR-active labels and Au/Ag hollow-shell assembled silica nanospheres. A 93% of NIR-SERRS dots is detectable at a single-particle level and signal intensity is 100-fold stronger than that from nonresonant molecule-labeled spherical Au NPs (80 nm). The result of SERRS-based antibody validation is comparable to that of the conventional method using single-photon-emission computed tomography. The NIR-SERRS-based strategy is an alternate validation method which provides cost-effective and accurate multiplexing measurements for antibody-based drug development. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Update of Standard Practices for New Method Validation in Forensic Toxicology.
Wille, Sarah M R; Coucke, Wim; De Baere, Thierry; Peters, Frank T
2017-01-01
International agreement concerning validation guidelines is important to obtain quality forensic bioanalytical research and routine applications as it all starts with the reporting of reliable analytical data. Standards for fundamental validation parameters are provided in guidelines as those from the US Food and Drug Administration (FDA), the European Medicines Agency (EMA), the German speaking Gesellschaft fur Toxikologie und Forensische Chemie (GTFCH) and the Scientific Working Group of Forensic Toxicology (SWGTOX). These validation parameters include selectivity, matrix effects, method limits, calibration, accuracy and stability, as well as other parameters such as carryover, dilution integrity and incurred sample reanalysis. It is, however, not easy for laboratories to implement these guidelines into practice as these international guidelines remain nonbinding protocols, that depend on the applied analytical technique, and that need to be updated according the analyst's method requirements and the application type. In this manuscript, a review of the current guidelines and literature concerning bioanalytical validation parameters in a forensic context is given and discussed. In addition, suggestions for the experimental set-up, the pros and cons of statistical approaches and adequate acceptance criteria for the validation of bioanalytical applications are given. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Measuring adverse events in helicopter emergency medical services: establishing content validity.
Patterson, P Daniel; Lave, Judith R; Martin-Gill, Christian; Weaver, Matthew D; Wadas, Richard J; Arnold, Robert M; Roth, Ronald N; Mosesso, Vincent N; Guyette, Francis X; Rittenberger, Jon C; Yealy, Donald M
2014-01-01
We sought to create a valid framework for detecting adverse events (AEs) in the high-risk setting of helicopter emergency medical services (HEMS). We assembled a panel of 10 expert clinicians (n = 6 emergency medicine physicians and n = 4 prehospital nurses and flight paramedics) affiliated with a large multistate HEMS organization in the Northeast US. We used a modified Delphi technique to develop a framework for detecting AEs associated with the treatment of critically ill or injured patients. We used a widely applied measure, the content validity index (CVI), to quantify the validity of the framework's content. The expert panel of 10 clinicians reached consensus on a common AE definition and four-step protocol/process for AE detection in HEMS. The consensus-based framework is composed of three main components: (1) a trigger tool, (2) a method for rating proximal cause, and (3) a method for rating AE severity. The CVI findings isolate components of the framework considered content valid. We demonstrate a standardized process for the development of a content-valid framework for AE detection. The framework is a model for the development of a method for AE identification in other settings, including ground-based EMS.
Benni, Paul B; MacLeod, David; Ikeda, Keita; Lin, Hung-Mo
2018-04-01
We describe the validation methodology for the NIRS based FORE-SIGHT ELITE ® (CAS Medical Systems, Inc., Branford, CT, USA) tissue oximeter for cerebral and somatic tissue oxygen saturation (StO 2 ) measurements for adult subjects submitted to the United States Food and Drug Administration (FDA) to obtain clearance for clinical use. This validation methodology evolved from a history of NIRS validations in the literature and FDA recommended use of Deming regression and bootstrapping statistical validation methods. For cerebral validation, forehead cerebral StO 2 measurements were compared to a weighted 70:30 reference (REF CX B ) of co-oximeter internal jugular venous and arterial blood saturation of healthy adult subjects during a controlled hypoxia sequence, with a sensor placed on the forehead. For somatic validation, somatic StO 2 measurements were compared to a weighted 70:30 reference (REF CX S ) of co-oximetry central venous and arterial saturation values following a similar protocol, with sensors place on the flank, quadriceps muscle, and calf muscle. With informed consent, 25 subjects successfully completed the cerebral validation study. The bias and precision (1 SD) of cerebral StO 2 compared to REF CX B was -0.14 ± 3.07%. With informed consent, 24 subjects successfully completed the somatic validation study. The bias and precision of somatic StO 2 compared to REF CX S was 0.04 ± 4.22% from the average of flank, quadriceps, and calf StO 2 measurements to best represent the global whole body REF CX S . The NIRS validation methods presented potentially provide a reliable means to test NIRS monitors and qualify them for clinical use.
Schmidt, Kathrin S; Mankertz, Joachim
2018-06-01
A sensitive and robust LC-MS/MS method allowing the rapid screening and confirmation of selective androgen receptor modulators in bovine urine was developed and successfully validated according to Commission Decision 2002/657/EC, chapter 3.1.3 'alternative validation', by applying a matrix-comprehensive in-house validation concept. The confirmation of the analytes in the validation samples was achieved both on the basis of the MRM ion ratios as laid down in Commission Decision 2002/657/EC and by comparison of their enhanced product ion (EPI) spectra with a reference mass spectral library by making use of the QTRAP technology. Here, in addition to the MRM survey scan, EPI spectra were generated in a data-dependent way according to an information-dependent acquisition criterion. Moreover, stability studies of the analytes in solution and in matrix according to an isochronous approach proved the stability of the analytes in solution and in matrix for at least the duration of the validation study. To identify factors that have a significant influence on the test method in routine analysis, a factorial effect analysis was performed. To this end, factors considered to be relevant for the method in routine analysis (e.g. operator, storage duration of the extracts before measurement, different cartridge lots and different hydrolysis conditions) were systematically varied on two levels. The examination of the extent to which these factors influence the measurement results of the individual analytes showed that none of the validation factors exerts a significant influence on the measurement results.
Validation of Gujarati Version of ABILOCO-Kids Questionnaire
Diwan, Jasmin; Patel, Pankaj; Bansal, Ankita B.
2015-01-01
Background ABILOCO-Kids is a measure of locomotion ability for children with cerebral palsy (CP) aged 6 to 15 years & is available in English & French. Aim To validate the Gujarati version of ABILOCO-Kids questionnaire to be used in clinical research on Gujarati population. Materials and Methods ABILOCO-Kids questionnaire was translated into Gujarati from English using forward-backward-forward method. To ensure face & content validity of Gujarati version using group consensus method, each item was examined by group of experts having mean experience of 24.62 years in field of paediatric and paediatric physiotherapy. Each item was analysed for content, meaning, wording, format, ease of administration & scoring. Each item was scored by expert group as either accepted, rejected or accepted with modification. Procedure was continued until 80% of consensus for all items. Concurrent validity was examined on 55 children with Cerebral Palsy (6-15 years) of all Gross Motor Functional Classification System (GMFCS) level & all clinical types by correlating score of ABILOCO-Kids with Gross Motor Functional Measure & GMFCS. Result In phase 1 of validation, 16 items were accepted as it is; 22 items accepted with modification & 3 items went for phase 2 validation. For concurrent validity, highly significant positive correlation was found between score of ABILOCO-Kids & total GMFM (r=0.713, p<0.005) & highly significant negative correlation with GMFCS (r= -0.778, p<0.005). Conclusion Gujarati translated version of ABILOCO-Kids questionnaire has good face & content validity as well as concurrent validity which can be used to measure caregiver reported locomotion ability in children with CP. PMID:26557603
Schiffman, Eric L.; Truelove, Edmond L.; Ohrbach, Richard; Anderson, Gary C.; John, Mike T.; List, Thomas; Look, John O.
2011-01-01
AIMS The purpose of the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Validation Project was to assess the diagnostic validity of this examination protocol. An overview is presented, including Axis I and II methodology and descriptive statistics for the study participant sample. This paper details the development of reliable methods to establish the reference standards for assessing criterion validity of the Axis I RDC/TMD diagnoses. Validity testing for the Axis II biobehavioral instruments was based on previously validated reference standards. METHODS The Axis I reference standards were based on the consensus of 2 criterion examiners independently performing a comprehensive history, clinical examination, and evaluation of imaging. Intersite reliability was assessed annually for criterion examiners and radiologists. Criterion exam reliability was also assessed within study sites. RESULTS Study participant demographics were comparable to those of participants in previous studies using the RDC/TMD. Diagnostic agreement of the criterion examiners with each other and with the consensus-based reference standards was excellent with all kappas ≥ 0.81, except for osteoarthrosis (moderate agreement, k = 0.53). Intrasite criterion exam agreement with reference standards was excellent (k ≥ 0.95). Intersite reliability of the radiologists for detecting computed tomography-disclosed osteoarthrosis and magnetic resonance imaging-disclosed disc displacement was good to excellent (k = 0.71 and 0.84, respectively). CONCLUSION The Validation Project study population was appropriate for assessing the reliability and validity of the RDC/TMD Axis I and II. The reference standards used to assess the validity of Axis I TMD were based on reliable and clinically credible methods. PMID:20213028
Wright, P; Edwards, S; Diallo, A; Jacobson, R
2006-01-01
Historically, the OIE has focused on test methods applicable to trade and the international movement of animals and animal products. With its expanding role as the World Organisation for Animal Health, the OIE has recognised the need to evaluate test methods relative to specific diagnostic applications other than trade. In collaboration with its international partners, the OIE solicited input from experts through consultants' meetings on the development of guidelines for validation and certification of diagnostic assays for infectious animal diseases. Recommendations from the first meeting were formally adopted and have subsequently been acted upon by the OIE. A validation template has been developed that specifically requires a test to be fit or suited for its intended purpose (e.g. as a screening or a confirmatory test). This is a key criterion for validation. The template incorporates four distinct stages of validation, each of which has bearing on the evaluation of fitness for purpose. The OIE has just recently created a registry for diagnostic tests that fulfil these validation requirements. Assay developers are invited to submit validation dossiers to the OIE for evaluation by a panel of experts. Recognising that validation is an incremental process, tests methods achieving at least the first stages of validation may be provisionally accepted. To provide additional confidence in assay performance, the OIE, through its network of Reference Laboratories, has embarked on the development of evaluation panels. These panels would contain specially selected test samples that would assist in verifying fitness for purpose.
Wright, P; Edwards, S; Diallo, A; Jacobson, R
2007-01-01
Historically, the OIE has focussed on test methods applicable to trade and the international movement of animals and animal products. With its expanding role as the World Organisation for Animal Health, the OIE has recognised the need to evaluate test methods relative to specific diagnostic applications other than trade. In collaboration with its international partners, the OIE solicited input from experts through consultants meetings on the development of guidelines for validation and certification of diagnostic assays for infectious animal diseases. Recommendations from the first meeting were formally adopted and have subsequently been acted upon by the OIE. A validation template has been developed that specifically requires a test to be fit or suited for its intended purpose (e.g. as a screening or a confirmatory test). This is a key criterion for validation. The template incorporates four distinct stages of validation, each of which has bearing on the evaluation of fitness for purpose. The OIE has just recently created a registry for diagnostic tests that fulfil these validation requirements. Assay developers are invited to submit validation dossiers to the OIE for evaluation by a panel of experts. Recognising that validation is an incremental process, tests methods achieving at least the first stages of validation may be provisionally accepted. To provide additional confidence in assay performance, the OIE, through its network of Reference Laboratories, has embarked on the development of evaluation panels. These panels would contain specially selected test samples that would assist in verifying fitness for purpose.
Casartelli, Nicola; Müller, Roland; Maffiuletti, Nicola A
2010-11-01
The aim of the present study was to verify the validity and reliability of the Myotest accelerometric system (Myotest SA, Sion, Switzerland) for the assessment of vertical jump height. Forty-four male basketball players (age range: 9-25 years) performed series of squat, countermovement and repeated jumps during 2 identical test sessions separated by 2-15 days. Flight height was simultaneously quantified with the Myotest system and validated photoelectric cells (Optojump). Two calculation methods were used to estimate the jump height from Myotest recordings: flight time (Myotest-T) and vertical takeoff velocity (Myotest-V). Concurrent validity was investigated comparing Myotest-T and Myotest-V to the criterion method (Optojump), and test-retest reliability was also examined. As regards validity, Myotest-T overestimated jumping height compared to Optojump (p < 0.001) with a systematic bias of approximately 7 cm, even though random errors were low (2.7 cm) and intraclass correlation coefficients (ICCs) where high (>0.98), that is, excellent validity. Myotest-V overestimated jumping height compared to Optojump (p < 0.001), with high random errors (>12 cm), high limits of agreement ratios (>36%), and low ICCs (<0.75), that is, poor validity. As regards reliability, Myotest-T showed high ICCs (range: 0.92-0.96), whereas Myotest-V showed low ICCs (range: 0.56-0.89), and high random errors (>9 cm). In conclusion, Myotest-T is a valid and reliable method for the assessment of vertical jump height, and its use is legitimate for field-based evaluations, whereas Myotest-V is neither valid nor reliable.
Learning to recognize rat social behavior: Novel dataset and cross-dataset application.
Lorbach, Malte; Kyriakou, Elisavet I; Poppe, Ronald; van Dam, Elsbeth A; Noldus, Lucas P J J; Veltkamp, Remco C
2018-04-15
Social behavior is an important aspect of rodent models. Automated measuring tools that make use of video analysis and machine learning are an increasingly attractive alternative to manual annotation. Because machine learning-based methods need to be trained, it is important that they are validated using data from different experiment settings. To develop and validate automated measuring tools, there is a need for annotated rodent interaction datasets. Currently, the availability of such datasets is limited to two mouse datasets. We introduce the first, publicly available rat social interaction dataset, RatSI. We demonstrate the practical value of the novel dataset by using it as the training set for a rat interaction recognition method. We show that behavior variations induced by the experiment setting can lead to reduced performance, which illustrates the importance of cross-dataset validation. Consequently, we add a simple adaptation step to our method and improve the recognition performance. Most existing methods are trained and evaluated in one experimental setting, which limits the predictive power of the evaluation to that particular setting. We demonstrate that cross-dataset experiments provide more insight in the performance of classifiers. With our novel, public dataset we encourage the development and validation of automated recognition methods. We are convinced that cross-dataset validation enhances our understanding of rodent interactions and facilitates the development of more sophisticated recognition methods. Combining them with adaptation techniques may enable us to apply automated recognition methods to a variety of animals and experiment settings. Copyright © 2017 Elsevier B.V. All rights reserved.
Fazio, Tatiana Tatit; Singh, Anil Kumar; Kedor-Hackmann, Erika Rosa Maria; Santoro, Maria Inês Rocha Miritello
2007-03-12
Cleaning validation is an integral part of current good manufacturing practices in any pharmaceutical industry. Nowadays, azathioprine and several other pharmacologically potent pharmaceuticals are manufactured in same production area. Carefully designed cleaning validation and its evaluation can ensure that residues of azathioprine will not carry over and cross contaminate the subsequent product. The aim of this study was to validate simple analytical method for verification of residual azathioprine in equipments used in the production area and to confirm efficiency of cleaning procedure. The HPLC method was validated on a LC system using Nova-Pak C18 (3.9 mm x 150 mm, 4 microm) and methanol-water-acetic acid (20:80:1, v/v/v) as mobile phase at a flow rate of 1.0 mL min(-1). UV detection was made at 280 nm. The calibration curve was linear over a concentration range from 2.0 to 22.0 microg mL(-1) with a correlation coefficient of 0.9998. The detection limit (DL) and quantitation limit (QL) were 0.09 and 0.29 microg mL(-1), respectively. The intra-day and inter-day precision expressed as relative standard deviation (R.S.D.) were below 2.0%. The mean recovery of method was 99.19%. The mean extraction-recovery from manufacturing equipments was 83.5%. The developed UV spectrophotometric method could only be used as limit method to qualify or reject cleaning procedure in production area. Nevertheless, the simplicity of spectrophotometric method makes it useful for routine analysis of azathioprine residues on cleaned surface and as an alternative to proposed HPLC method.
Inter-Disciplinary Collaboration in Support of the Post-Standby TREAT Mission
DOE Office of Scientific and Technical Information (OSTI.GOV)
DeHart, Mark; Baker, Benjamin; Ortensi, Javier
Although analysis methods have advanced significantly in the last two decades, high fidelity multi- physics methods for reactors systems have been under development for only a few years and are not presently mature nor deployed. Furthermore, very few methods provide the ability to simulate rapid transients in three dimensions. Data for validation of advanced time-dependent multi- physics is sparse; at TREAT, historical data were not collected for the purpose of validating three-dimensional methods, let alone multi-physics simulations. Existing data continues to be collected to attempt to simulate the behavior of experiments and calibration transients, but it will be insufficient formore » the complete validation of analysis methods used for TREAT transient simulations. Hence, a 2018 restart will most likely occur without the direct application of advanced modeling and simulation methods. At present, the current INL modeling and simulation team plans to work with TREAT operations staff in performing reactor simulations with MAMMOTH, in parallel with the software packages currently being used in preparation for core restart (e.g., MCNP5, RELAP5, ABAQUS). The TREAT team has also requested specific measurements to be performed during startup testing, currently scheduled to run from February to August of 2018. These startup measurements will be crucial in validating the new analysis methods in preparation for ultimate application for TREAT operations and experiment design. This document describes the collaboration between modeling and simulation staff and restart, operations, instrumentation and experiment development teams to be able to effectively interact and achieve successful validation work during restart testing.« less
Novel materials based on chitosan, its derivatives and cellulose fibres
NASA Astrophysics Data System (ADS)
Fernandes, Susana Cristina de Matos
O presente trabalho tem como principal objectivo o desenvolvimento de novos materiais baseados em quitosano, seus derivados e celulose, na forma de nanofibras ou de papel. Em primeiro lugar procedeu-se a purificacao das amostras comerciais de quitosano e a sua caracterizacao exaustiva em termos morfologicos e fisicoquimicos. Devido a valores contraditorios encontrados na literatura relativamente a energia de superficie do quitosano, e tendo em conta a sua utilizacao como precursor de modificacoes quimicas e a sua aplicacao em misturas com outros materiais, realizou-se tambem um estudo sistematico da determinacao da energia de superficie do quitosano, da quitina e seus respectivos homologos monomericos, por medicao de ângulos de contacto Em todas as amostras comerciais destes polimeros identificaram-se impurezas nao polares que estao associadas a erros na determinacao da componente polar da energia de superficie. Apos a remocao destas impurezas, o valor da energia total de superficie (gs), e em particular da sua componente polar, aumentou consideravelmente. Depois de purificadas e caracterizadas, algumas das amostras de quitosano foram entao usadas na preparacao de filmes nanocompositos, nomeadamente dois quitosanos com diferentes graus de polimerizacao, correspondentes derivados soluveis em agua (cloreto de N-(3-(N,N,N-trimetilamonio)-2- hidroxipropilo) de quitosano) e nanofibras de celulose como reforco (celulose nanofibrilada (NFC) e celulose bacteriana (BC). Estes filmes transparentes foram preparados atraves de um processo simples e com conotacao 'verde' pela dispersao homogenea de diferentes teores de NFC (ate 60%) e BC (ate 40%) nas solucoes de quitosano (1.5% w/v) seguida da evaporacao do solvente. Os filmes obtidos foram depois caracterizados por diversas tecnicas, tais como SEM, AFM, difraccao de raio-X, TGA, DMA, ensaios de traccao e espectroscopia no visivel. Estes filmes sao altamente transparentes e apresentam melhores propriedades mecânicas e maior estabilidade termica do que os correspondentes filmes sem reforco. Outra abordagem deste trabalho envolveu o revestimento de folhas de papel de E. globulus com quitosano e dois derivados, um derivado fluorescente e um derivado soluvel em agua, numa maquina de revestimentos ('maquina de colagem') a escala piloto. Este estudo envolveu inicialmente a deposicao de 1 a 5 camadas do derivado de quitosano fluorescente sobre as folhas de papel de forma a estudar a sua distribuicao nas folhas em termos de espalhamento e penetracao, atraves de medicoes de reflectância e luminescencia. Os resultados mostraram que, por um lado, a distribuicao do quitosano na superficie era homogenea e que, por outro lado, a sua penetracao atraves dos poros do papel cessou apos tres deposicoes. Depois da terceira camada verificou-se a formacao de um filme continuo de quitosano sobre a superficie do papel. Estes resultados mostram que este derivado de quitosano fluorescente pode ser utilizado como marcador na optimizacao e compreensao de mecanismos de deposicao de quitosano em papel e outros substratos. Depois de conhecida a distribuicao do quitosano nas folhas de papel, estudou-se o efeito do revestimento de quitosano e do seu derivado soluvel em agua nas propriedades finais do papel. As propriedades morfologicas, mecânicas, superficiais, opticas, assim como a permeabilidade ao ar e ao vapor de agua, a aptidao a impressao e o envelhecimento do papel, foram exaustivamente avaliadas. De uma forma geral, os revestimentos com quitosano e com o seu derivado soluvel em agua tiveram um impacto positivo nas propriedades finais do papel, que se mostrou ser dependente do numero de camadas depositadas. Os resultados tambem mostraram que os papeis revestidos com o derivado soluvel em agua apresentaram melhores propriedades opticas, aptidao a impressao e melhores resultados em relacao ao envelhecimento do que os papeis revestidos com quitosano. Assim, o uso de derivados de quitosano soluveis em agua em processos de revestimento de papel representa uma estrategia bastante interessante e sustentavel para o desenvolvimento de novos materiais funcionais ou na melhoria das propriedades finais dos papeis. Por fim, tendo como objectivo valorizar os residuos e fraccoes menos nobres da quitina e do quitosano provenientes da industria transformadora, estes polimeros foram convertidos em poliois viscosos atraves de uma reaccao simples de oxipropilacao. Este processo tem tambem conotacao "verde" uma vez que nao requer solvente, nao origina subprodutos e nao exige nenhuma operacao especifica (separacao, purificacao, etc) para isolar o produto da reaccao. As amostras de quitina e quitosano foram pre-activadas com KOH e depois modificadas com um excesso de oxido de propileno (PO) num reactor apropriado. Em todos os casos, o produto da reaccao foi um liquido viscoso composto por quitina ou quitosano oxipropilados e homopolimero de PO. Estas duas fraccoes foram separadas e caracterizadas.
Hinds, P S; Scandrett-Hibden, S; McAulay, L S
1990-04-01
The reliability and validity of qualitative research findings are viewed with scepticism by some scientists. This scepticism is derived from the belief that qualitative researchers give insufficient attention to estimating reliability and validity of data, and the differences between quantitative and qualitative methods in assessing data. The danger of this scepticism is that relevant and applicable research findings will not be used. Our purpose is to describe an evaluative strategy for use with qualitative data, a strategy that is a synthesis of quantitative and qualitative assessment methods. Results of the strategy and factors that influence its use are also described.
In-vitro Equilibrium Phosphate Binding Study of Sevelamer Carbonate by UV-Vis Spectrophotometry.
Prasaja, Budi; Syabani, M Maulana; Sari, Endah; Chilmi, Uci; Cahyaningsih, Prawitasari; Kosasih, Theresia Weliana
2018-06-12
Sevelamer carbonate is a cross-linked polymeric amine; it is the active ingredient in Renvela ® tablets. US FDA provides recommendation for demonstrating bioequivalence for the development of a generic product of sevelamer carbonte using in-vitro equilibrium binding study. A simple UV-vis spectrophotometry method was developed and validated for quantification of free phosphate to determine the binding parameter constant of sevelamer. The method validation demonstrated the specificity, limit of quantification, accuracy and precision of measurements. The validated method has been successfully used to analyze samples in in-vitro equilibrium binding study for demonstrating bioequivalence. © Georg Thieme Verlag KG Stuttgart · New York.
Ocque, Andrew J; Hagler, Colleen E; Difrancesco, Robin; Woolwine-Cunningham, Yvonne; Bednasz, Cindy J; Morse, Gene D; Talal, Andrew H
2016-07-01
Determination of paritaprevir and ritonavir in rat liver tissue samples. We successfully validated a UPLC-MS/MS method to measure paritaprevir and ritonavir in rat liver using deuterated internal standards (d8-paritapervir and d6-ritonavir). The method is linear from 20 to 20,000 and 5 to 10,000 pg on column for paritaprevir and ritonavir, respectively, and is normalized per milligram tissue. Interday and intraday variability ranged from 0.591 to 5.33% and accuracy ranged from -6.68 to 10.1% for quality control samples. The method was then applied to the measurement of paritaprevir and ritonavir in rat liver tissue samples from a pilot study. The validated method is suitable for measurement of paritaprevir and ritonavir within rat liver tissue samples for PK studies.
Brunelle, Sharon L
2016-01-01
A previously validated method for determination of chondroitin sulfate in raw materials and dietary supplements was submitted to the AOAC Expert Review Panel (ERP) for Stakeholder Panel on Dietary Supplements Set 1 Ingredients (Anthocyanins, Chondroitin, and PDE5 Inhibitors) for consideration of First Action Official Methods(SM) status. The ERP evaluated the single-laboratory validation results against AOAC Standard Method Performance Requirements 2014.009. With recoveries of 100.8-101.6% in raw materials and 105.4-105.8% in finished products and precision of 0.25-1.8% RSDr within-day and 1.6-4.72% RSDr overall, the ERP adopted the method for First Action Official Methods status and provided recommendations for achieving Final Action status.
Validation of GC and HPLC systems for residue studies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williams, M.
1995-12-01
For residue studies, GC and HPLC system performance must be validated prior to and during use. One excellent measure of system performance is the standard curve and associated chromatograms used to construct that curve. The standard curve is a model of system response to an analyte over a specific time period, and is prima facia evidence of system performance beginning at the auto sampler and proceeding through the injector, column, detector, electronics, data-capture device, and printer/plotter. This tool measures the performance of the entire chromatographic system; its power negates most of the benefits associated with costly and time-consuming validation ofmore » individual system components. Other measures of instrument and method validation will be discussed, including quality control charts and experimental designs for method validation.« less
Bias correction for selecting the minimal-error classifier from many machine learning models.
Ding, Ying; Tang, Shaowu; Liao, Serena G; Jia, Jia; Oesterreich, Steffi; Lin, Yan; Tseng, George C
2014-11-15
Supervised machine learning is commonly applied in genomic research to construct a classifier from the training data that is generalizable to predict independent testing data. When test datasets are not available, cross-validation is commonly used to estimate the error rate. Many machine learning methods are available, and it is well known that no universally best method exists in general. It has been a common practice to apply many machine learning methods and report the method that produces the smallest cross-validation error rate. Theoretically, such a procedure produces a selection bias. Consequently, many clinical studies with moderate sample sizes (e.g. n = 30-60) risk reporting a falsely small cross-validation error rate that could not be validated later in independent cohorts. In this article, we illustrated the probabilistic framework of the problem and explored the statistical and asymptotic properties. We proposed a new bias correction method based on learning curve fitting by inverse power law (IPL) and compared it with three existing methods: nested cross-validation, weighted mean correction and Tibshirani-Tibshirani procedure. All methods were compared in simulation datasets, five moderate size real datasets and two large breast cancer datasets. The result showed that IPL outperforms the other methods in bias correction with smaller variance, and it has an additional advantage to extrapolate error estimates for larger sample sizes, a practical feature to recommend whether more samples should be recruited to improve the classifier and accuracy. An R package 'MLbias' and all source files are publicly available. tsenglab.biostat.pitt.edu/software.htm. ctseng@pitt.edu Supplementary data are available at Bioinformatics online. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Baietto, Lorena; D'Avolio, Antonio; Marra, Cristina; Simiele, Marco; Cusato, Jessica; Pace, Simone; Ariaudo, Alessandra; De Rosa, Francesco Giuseppe; Di Perri, Giovanni
2012-11-01
Therapeutic drug monitoring (TDM) of triazoles is widely used in clinical practice to optimize therapy. TDM is limited by technical problems and cost considerations, such as sample storage and dry-ice shipping. We aimed to develop and validate a new method to analyse itraconazole, posaconazole and voriconazole in plasma spotted on dry sample spot devices (DSSDs) and to quantify them by an HPLC system. Extraction from DSSDs was done using n-hexane/ethyl acetate and ammonia solution. Samples were analysed using HPLC with mass spectrometry (HPLC-MS). Accuracy and precision were assayed by inter- and intra-day validation. The stability of triazoles in plasma spotted on DSSDs was investigated at room temperature for 1 month. The method was compared with a validated standard HPLC method for quantification of triazoles in human plasma. Mean inter- and intra-day accuracy and precision were <15% for all compounds. Triazoles were stable for 2 weeks at room temperature. The method was linear (r(2) > 0.999) in the range 0.031-8 mg/L for itraconazole and posaconazole, and 0.058-15 mg/L for voriconazole. High sensitivity was observed; limits of detection were 0.008, 0.004 and 0.007 mg/L for itraconazole, posaconazole and voriconazole, respectively. A high degree of correlation (r(2) > 0.94) was obtained between the DSSD method and the standard method of analysis. The method that we developed and validated to quantify triazoles in human plasma spotted on DSSDs is accurate and precise. It overcomes problems related to plasma sample storage and shipment, allowing TDM to be performed in a cheaper and safer manner.
A Complex Systems Approach to Causal Discovery in Psychiatry.
Saxe, Glenn N; Statnikov, Alexander; Fenyo, David; Ren, Jiwen; Li, Zhiguo; Prasad, Meera; Wall, Dennis; Bergman, Nora; Briggs, Ernestine C; Aliferis, Constantin
2016-01-01
Conventional research methodologies and data analytic approaches in psychiatric research are unable to reliably infer causal relations without experimental designs, or to make inferences about the functional properties of the complex systems in which psychiatric disorders are embedded. This article describes a series of studies to validate a novel hybrid computational approach--the Complex Systems-Causal Network (CS-CN) method-designed to integrate causal discovery within a complex systems framework for psychiatric research. The CS-CN method was first applied to an existing dataset on psychopathology in 163 children hospitalized with injuries (validation study). Next, it was applied to a much larger dataset of traumatized children (replication study). Finally, the CS-CN method was applied in a controlled experiment using a 'gold standard' dataset for causal discovery and compared with other methods for accurately detecting causal variables (resimulation controlled experiment). The CS-CN method successfully detected a causal network of 111 variables and 167 bivariate relations in the initial validation study. This causal network had well-defined adaptive properties and a set of variables was found that disproportionally contributed to these properties. Modeling the removal of these variables resulted in significant loss of adaptive properties. The CS-CN method was successfully applied in the replication study and performed better than traditional statistical methods, and similarly to state-of-the-art causal discovery algorithms in the causal detection experiment. The CS-CN method was validated, replicated, and yielded both novel and previously validated findings related to risk factors and potential treatments of psychiatric disorders. The novel approach yields both fine-grain (micro) and high-level (macro) insights and thus represents a promising approach for complex systems-oriented research in psychiatry.
This document is a standardized single laboratory validated liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the detection and quantification of cyanotoxins (combined intracellular and extracellular) in ambient freshwaters.
Validation of Screening Assays for Developmental Toxicity: An Exposure-Based Approach
There continue to be widespread efforts to develop assay methods for developmental toxicity that are shorter than the traditional Segment 2 study and use fewer or no animals. As with any alternative test method, novel developmental toxicity assays must be validated by evaluating ...
USDA-ARS?s Scientific Manuscript database
Although quantitative analytical methods must be empirically validated prior to their actual use in a variety of applications, including regulatory monitoring of chemical adulterants in foods, validation of qualitative method performance for the analytes and matrices of interest is frequently ignore...
USDA-ARS?s Scientific Manuscript database
A liquid chromatography-mass spectrometry (LC/MS) method for simultaneous quantitation of seven ergot alkaloids (lysergic acid, ergonovine, ergovaline, ergocornine, ergotamine, ergocryptine and ergocrystine) in vascular tissue was developed and validated. Reverse-phase chromatography, coupled to an...
Can Formal Methods Provide (Necessary and) Sufficient Conditions for Measurement?
ERIC Educational Resources Information Center
Mari, Luca
2017-01-01
In his focus article, "Rethinking Traditional Methods of Survey Validation," published in this issue of "Measurement: Interdisciplinary Research and Perspectives," Andrew Maul introduces and discusses several foundational issues and concludes that self-report measures may be particularly difficult to validate and may fall short…
Moving beyond Traditional Methods of Survey Validation
ERIC Educational Resources Information Center
Maul, Andrew
2017-01-01
In his focus article, "Rethinking Traditional Methods of Survey Validation," published in this issue of "Measurement: Interdisciplinary Research and Perspectives," Andrew Maul wrote that it is commonly believed that self-report, survey-based instruments can be used to measure a wide range of psychological attributes, such as…
Validation of the ULCEAT methodology by applying it in retrospect to the Roboticbed.
Nakamura, Mio; Suzurikawa, Jun; Tsukada, Shohei; Kume, Yohei; Kawakami, Hideo; Inoue, Kaoru; Inoue, Takenobu
2015-01-01
In answer to the increasing demand for care by the Japanese oldest portion of the population, an extensive programme of life support robots is under development, advocated by the Japanese government. Roboticbed® (RB) is developed to facilitate patients in their daily life in making independent transfers from and to the bed. The bed is intended both for elderly and persons with a disability. The purpose of this study is to examine the validity of the user and user's life centred clinical evaluation of assistive technology (ULCEAT) methodology. To support user centred development of life support robots the ULCEAT method was developed. By means of the ULCEAT method the target users and the use environment were re-established in an earlier study. The validity of the method is tested by re-evaluating the development of RB in retrospect. Six participants used the first prototype of RB (RB1) and eight participants used the second prototype of RB (RB2). The results indicated that the functionality was improved owing to the end-user evaluations. Therefore, we confirmed the content validity of the proposed ULCEAT method. In this study we confirmed the validation of the ULCEAT methodology by applying it in retrospect to RB using development process. This method will be used for the development of Life-support robots and prototype assistive technologies.
ERIC Educational Resources Information Center
Haskins, Jack B.
A survey method was developed and used to determine interest in new course topics at the Learning Institute for Elders (LIFE) at the University of Central Florida. In the absence of a known validated method for course concept testing, this approach was modeled after the "message pretesting," or formative, research used and validated in…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-21
... methods for potential use in the EPA EDSP. The evaluation indicated that no in vitro ER- or AR-based test... considered a high priority based on the lack of adequately validated test methods and the regulatory and... Limitations of the LUMI-CELL[supreg] ER (BG1Luc ER TA) Test Method, An In Vitro Assay for Identifying Human...
Helicopter rotor loads using a matched asymptotic expansion technique
NASA Technical Reports Server (NTRS)
Pierce, G. A.; Vaidyanathan, A. R.
1981-01-01
The theoretical basis and computational feasibility of the Van Holten method, and its performance and range of validity by comparison with experiment and other approximate methods was examined. It is found that within the restrictions of incompressible, potential flow and the assumption of small disturbances, the method does lead to a valid description of the flow. However, the method begins to break down under conditions favoring nonlinear effects such as wake distortion and blade/rotor interaction.
Validating Test Score Meaning and Defending Test Score Use: Different Aims, Different Methods
ERIC Educational Resources Information Center
Cizek, Gregory J.
2016-01-01
Advances in validity theory and alacrity in validation practice have suffered because the term "validity" has been used to refer to two incompatible concerns: (1) the degree of support for specified interpretations of test scores (i.e. intended score meaning) and (2) the degree of support for specified applications (i.e. intended test…
Hand-touch method for detection of neonatal hypothermia in Nepal.
Tuitui, Roshani Laxmi; Suwal, Satya Narayan; Shrestha, Sarala
2011-06-01
Neonatal hypothermia is the fourth leading causes of neonatal death in Nepal. Thus, it is the caregivers' responsibility to identify the hypothermia by using valid and less time consuming method like hand-touch method. Therefore, we examined the diagnostic validity of hand-touch method against low-reading mercury (LRM) thermometer for detecting neonatal hypothermia. We assessed neonate's temperature first by hand-touch method, then by LRM thermometer and tympanic thermometer among 100 full-term neonates, delivered within 24 h in Maternity Ward of Tribhuvan University Teaching Hospital, Nepal. We used World Health Organization (1997) criteria for classification of neonatal hypothermia. The sensitivity and specificity of the hand-touch method for detection of neonatal hypothermia were 95.6% and 70.1% against LRM thermometer and 76.6% and 83% against the tympanic thermometer, respectively. Touching method is practical and therefore has a good diagnostic validity; it can be introduced in essential newborn care package after giving adequate training to caregivers.
Pyka, Alina; Budzisz, Marika; Dołowy, Małgorzata
2013-01-01
Adsorption thin layer chromatography (NP-TLC) with densitometry has been established for the identification and the quantification of acetaminophen in three leading commercial products of pharmaceutical tablets coded as brand: P1 (Product no. 1), P2 (Product no. 2), and P3 (Product no. 3). Applied chromatographic conditions have separated acetaminophen from its related substances, namely, 4-aminophenol and and 4′-chloroacetanilide. UV densitometry was performed in absorbance mode at 248 nm. The presented method was validated by specificity, range, linearity, accuracy, precision, detection limit, quantitative limit, and robustness. The TLC-densitometric method was also compared with a pharmacopeial UV-spectrophotometric method for the assay of acetaminophen, and the results confirmed statistically that the NP-TLC-densitometric method can be used as a substitute method. It could be said that the validated NP-TLC-densitometric method is suitable for the routine analysis of acetaminophen in quantity control laboratories. PMID:24063006
Alam, Prawez; Foudah, Ahmed I.; Zaatout, Hala H.; T, Kamal Y; Abdel-Kader, Maged S.
2017-01-01
Background: A simple and sensitive thin-layer chromatographic method has been established for quantification of glycyrrhizin in Glycyrrhiza glabra rhizome and baby herbal formulations by validated Reverse Phase HPTLC method. Materials and Methods: RP-HPTLC Method was carried out using glass coated with RP-18 silica gel 60 F254S HPTLC plates using methanol-water (7: 3 v/v) as mobile phase. Results: The developed plate was scanned and quantified densitometrically at 256 nm. Glycyrrhizin peaks from Glycyrrhiza glabra rhizome and baby herbal formulations were identified by comparing their single spot at Rf = 0.63 ± 0.01. Linear regression analysis revealed a good linear relationship between peak area and amount of glycyrrhizin in the range of 2000-7000 ng/band. Conclusion: The method was validated, in accordance with ICH guidelines for precision, accuracy, and robustness. The proposed method will be useful to enumerate the therapeutic dose of glycyrrhizin in herbal formulations as well as in bulk drug. PMID:28573236
Suggestions for Rethinking Validation
ERIC Educational Resources Information Center
Fisher, William P., Jr.
2017-01-01
In this commentary on "Rethinking Traditional Methods of Survey Validation," found in this issue of "Measurement: Interdisciplinary Research and Perspectives," William Fisher writes that Maul's paper raises issues of validity in survey-based measurement that deserve far wider consideration and scrutiny than they typically…
An empirical assessment of validation practices for molecular classifiers
Castaldi, Peter J.; Dahabreh, Issa J.
2011-01-01
Proposed molecular classifiers may be overfit to idiosyncrasies of noisy genomic and proteomic data. Cross-validation methods are often used to obtain estimates of classification accuracy, but both simulations and case studies suggest that, when inappropriate methods are used, bias may ensue. Bias can be bypassed and generalizability can be tested by external (independent) validation. We evaluated 35 studies that have reported on external validation of a molecular classifier. We extracted information on study design and methodological features, and compared the performance of molecular classifiers in internal cross-validation versus external validation for 28 studies where both had been performed. We demonstrate that the majority of studies pursued cross-validation practices that are likely to overestimate classifier performance. Most studies were markedly underpowered to detect a 20% decrease in sensitivity or specificity between internal cross-validation and external validation [median power was 36% (IQR, 21–61%) and 29% (IQR, 15–65%), respectively]. The median reported classification performance for sensitivity and specificity was 94% and 98%, respectively, in cross-validation and 88% and 81% for independent validation. The relative diagnostic odds ratio was 3.26 (95% CI 2.04–5.21) for cross-validation versus independent validation. Finally, we reviewed all studies (n = 758) which cited those in our study sample, and identified only one instance of additional subsequent independent validation of these classifiers. In conclusion, these results document that many cross-validation practices employed in the literature are potentially biased and genuine progress in this field will require adoption of routine external validation of molecular classifiers, preferably in much larger studies than in current practice. PMID:21300697
USDA-ARS?s Scientific Manuscript database
A high-throughput qualitative screening and identification method for 9 aminoglycosides of regulatory interest has been developed, validated, and implemented for bovine kidney, liver, and muscle tissues. The method involves extraction at previously validated conditions, cleanup using disposable pip...
ePortfolios: The Method of Choice for Validation
ERIC Educational Resources Information Center
Scott, Ken; Kim, Jichul
2015-01-01
Community colleges have long been institutions of higher education in the arenas of technical education and training, as well as preparing students for transfer to universities. While students are engaged in their student learning outcomes, projects, research, and community service, how have these students validated their work? One method of…
This document is a standardized, single laboratory validated liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for the detection of cyanotoxins—microsystins and nodularin (combined intracellular and extracellular)—in ambient freshwaters.
Validation in context of bioanalytical research papers.
Rogatsky, Eduard; Tomuta, Vlad; Stein, Daniel T
2006-11-01
We have noticed the growing amount of application papers, mainly focused on detailed description of analytical assay validation with limited discussion of method development and optimization in top-ranked chromatographic journals. We analyze the implications of this trend and suggest a re-emphasis on the intellectual component in method development.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-02
...] Draft Guidance for Industry and FDA Staff: Processing/ Reprocessing Medical Devices in Health Care... Devices in Health Care Settings: Validation Methods and Labeling.'' The recommendations in this guidance... Staff: Processing/Reprocessing Medical Devices in Health Care Settings: Validation Methods and Labeling...
Vasak, Christoph; Strbac, Georg D; Huber, Christian D; Lettner, Stefan; Gahleitner, André; Zechner, Werner
2015-02-01
The study aims to evaluate the accuracy of the NobelGuide™ (Medicim/Nobel Biocare, Göteborg, Sweden) concept maximally reducing the influence of clinical and surgical parameters. Moreover, the study was to compare and validate two validation procedures versus a reference method. Overall, 60 implants were placed in 10 artificial edentulous mandibles according to the NobelGuide™ protocol. For merging the pre- and postoperative DICOM data sets, three different fusion methods (Triple Scan Technique, NobelGuide™ Validation software, and AMIRA® software [VSG - Visualization Sciences Group, Burlington, MA, USA] as reference) were applied. Discrepancies between the virtual and the actual implant positions were measured. The mean deviations measured with AMIRA® were 0.49 mm (implant shoulder), 0.69 mm (implant apex), and 1.98°mm (implant axis). The Triple Scan Technique as well as the NobelGuide™ Validation software revealed similar deviations compared with the reference method. A significant correlation between angular and apical deviations was seen (r = 0.53; p < .001). A greater implant diameter was associated with greater deviations (p = .03). The Triple Scan Technique as a system-independent validation procedure as well as the NobelGuide™ Validation software are in accordance with the AMIRA® software. The NobelGuide™ system showed similar or less spatial and angular deviations compared with others. © 2013 Wiley Periodicals, Inc.
Paliwal, Nikhil; Damiano, Robert J; Varble, Nicole A; Tutino, Vincent M; Dou, Zhongwang; Siddiqui, Adnan H; Meng, Hui
2017-12-01
Computational fluid dynamics (CFD) is a promising tool to aid in clinical diagnoses of cardiovascular diseases. However, it uses assumptions that simplify the complexities of the real cardiovascular flow. Due to high-stakes in the clinical setting, it is critical to calculate the effect of these assumptions in the CFD simulation results. However, existing CFD validation approaches do not quantify error in the simulation results due to the CFD solver's modeling assumptions. Instead, they directly compare CFD simulation results against validation data. Thus, to quantify the accuracy of a CFD solver, we developed a validation methodology that calculates the CFD model error (arising from modeling assumptions). Our methodology identifies independent error sources in CFD and validation experiments, and calculates the model error by parsing out other sources of error inherent in simulation and experiments. To demonstrate the method, we simulated the flow field of a patient-specific intracranial aneurysm (IA) in the commercial CFD software star-ccm+. Particle image velocimetry (PIV) provided validation datasets for the flow field on two orthogonal planes. The average model error in the star-ccm+ solver was 5.63 ± 5.49% along the intersecting validation line of the orthogonal planes. Furthermore, we demonstrated that our validation method is superior to existing validation approaches by applying three representative existing validation techniques to our CFD and experimental dataset, and comparing the validation results. Our validation methodology offers a streamlined workflow to extract the "true" accuracy of a CFD solver.
Validity and Reliability of the Turkish Chronic Pain Acceptance Questionnaire
Akmaz, Hazel Ekin; Uyar, Meltem; Kuzeyli Yıldırım, Yasemin; Akın Korhan, Esra
2018-01-01
Background: Pain acceptance is the process of giving up the struggle with pain and learning to live a worthwhile life despite it. In assessing patients with chronic pain in Turkey, making a diagnosis and tracking the effectiveness of treatment is done with scales that have been translated into Turkish. However, there is as yet no valid and reliable scale in Turkish to assess the acceptance of pain. Aims: To validate a Turkish version of the Chronic Pain Acceptance Questionnaire developed by McCracken and colleagues. Study Design: Methodological and cross sectional study. Methods: A simple randomized sampling method was used in selecting the study sample. The sample was composed of 201 patients, more than 10 times the number of items examined for validity and reliability in the study, which totaled 20. A patient identification form, the Chronic Pain Acceptance Questionnaire, and the Brief Pain Inventory were used to collect data. Data were collected by face-to-face interviews. In the validity testing, the content validity index was used to evaluate linguistic equivalence, content validity, construct validity, and expert views. In reliability testing of the scale, Cronbach’s α coefficient was calculated, and item analysis and split-test reliability methods were used. Principal component analysis and varimax rotation were used in factor analysis and to examine factor structure for construct concept validity. Results: The item analysis established that the scale, all items, and item-total correlations were satisfactory. The mean total score of the scale was 21.78. The internal consistency coefficient was 0.94, and the correlation between the two halves of the scale was 0.89. Conclusion: The Chronic Pain Acceptance Questionnaire, which is intended to be used in Turkey upon confirmation of its validity and reliability, is an evaluation instrument with sufficient validity and reliability, and it can be reliably used to examine patients’ acceptance of chronic pain. PMID:29843496
Chung, Mi Sun; Yang, Dong Hyun; Kim, Young-Hak; Kang, Soo-Jin; Jung, Joonho; Kim, Namkug; Heo, Seung-Ho; Baek, Seunghee; Seo, Joon Beom; Choi, Byoung Wook; Kang, Joon-Won; Lim, Tae-Hwan
2017-10-01
To validate a method for performing myocardial segmentation based on coronary anatomy using coronary CT angiography (CCTA). Coronary artery-based myocardial segmentation (CAMS) was developed for use with CCTA. To validate and compare this method with the conventional American Heart Association (AHA) classification, a single coronary occlusion model was prepared and validated using six pigs. The unstained occluded coronary territories of the specimens and corresponding arterial territories from CAMS and AHA segmentations were compared using slice-by-slice matching and 100 virtual myocardial columns. CAMS more precisely predicted ischaemic area than the AHA method, as indicated by 95% versus 76% (p < 0.001) of the percentage of matched columns (defined as percentage of matched columns of segmentation method divided by number of unstained columns in the specimen). According to the subgroup analyses, CAMS demonstrated a higher percentage of matched columns than the AHA method in the left anterior descending artery (100% vs. 77%; p < 0.001) and mid- (99% vs. 83%; p = 0.046) and apical-level territories of the left ventricle (90% vs. 52%; p = 0.011). CAMS is a feasible method for identifying the corresponding myocardial territories of the coronary arteries using CCTA. • CAMS is a feasible method for identifying corresponding coronary territory using CTA • CAMS is more accurate in predicting coronary territory than the AHA method • The AHA method may underestimate the ischaemic territory of LAD stenosis.
MRPrimer: a MapReduce-based method for the thorough design of valid and ranked primers for PCR
Kim, Hyerin; Kang, NaNa; Chon, Kang-Wook; Kim, Seonho; Lee, NaHye; Koo, JaeHyung; Kim, Min-Soo
2015-01-01
Primer design is a fundamental technique that is widely used for polymerase chain reaction (PCR). Although many methods have been proposed for primer design, they require a great deal of manual effort to generate feasible and valid primers, including homology tests on off-target sequences using BLAST-like tools. That approach is inconvenient for many target sequences of quantitative PCR (qPCR) due to considering the same stringent and allele-invariant constraints. To address this issue, we propose an entirely new method called MRPrimer that can design all feasible and valid primer pairs existing in a DNA database at once, while simultaneously checking a multitude of filtering constraints and validating primer specificity. Furthermore, MRPrimer suggests the best primer pair for each target sequence, based on a ranking method. Through qPCR analysis using 343 primer pairs and the corresponding sequencing and comparative analyses, we showed that the primer pairs designed by MRPrimer are very stable and effective for qPCR. In addition, MRPrimer is computationally efficient and scalable and therefore useful for quickly constructing an entire collection of feasible and valid primers for frequently updated databases like RefSeq. Furthermore, we suggest that MRPrimer can be utilized conveniently for experiments requiring primer design, especially real-time qPCR. PMID:26109350
On the analysis of very small samples of Gaussian repeated measurements: an alternative approach.
Westgate, Philip M; Burchett, Woodrow W
2017-03-15
The analysis of very small samples of Gaussian repeated measurements can be challenging. First, due to a very small number of independent subjects contributing outcomes over time, statistical power can be quite small. Second, nuisance covariance parameters must be appropriately accounted for in the analysis in order to maintain the nominal test size. However, available statistical strategies that ensure valid statistical inference may lack power, whereas more powerful methods may have the potential for inflated test sizes. Therefore, we explore an alternative approach to the analysis of very small samples of Gaussian repeated measurements, with the goal of maintaining valid inference while also improving statistical power relative to other valid methods. This approach uses generalized estimating equations with a bias-corrected empirical covariance matrix that accounts for all small-sample aspects of nuisance correlation parameter estimation in order to maintain valid inference. Furthermore, the approach utilizes correlation selection strategies with the goal of choosing the working structure that will result in the greatest power. In our study, we show that when accurate modeling of the nuisance correlation structure impacts the efficiency of regression parameter estimation, this method can improve power relative to existing methods that yield valid inference. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Validation of the Classroom Behavior Inventory
ERIC Educational Resources Information Center
Blunden, Dale; And Others
1974-01-01
Factor-analytic methods were used toassess contruct validity of the Classroom Behavior Inventory, a scale for rating behaviors associated with hyperactivity. The Classroom Behavior Inventory measures three dimensions of behavior: Hyperactivity, Hostility, and Sociability. Significant concurrent validity was obtained for only one Classroom Behavior…
High-order continuum kinetic method for modeling plasma dynamics in phase space
Vogman, G. V.; Colella, P.; Shumlak, U.
2014-12-15
Continuum methods offer a high-fidelity means of simulating plasma kinetics. While computationally intensive, these methods are advantageous because they can be cast in conservation-law form, are not susceptible to noise, and can be implemented using high-order numerical methods. Advances in continuum method capabilities for modeling kinetic phenomena in plasmas require the development of validation tools in higher dimensional phase space and an ability to handle non-cartesian geometries. To that end, a new benchmark for validating Vlasov-Poisson simulations in 3D (x,v x,v y) is presented. The benchmark is based on the Dory-Guest-Harris instability and is successfully used to validate a continuummore » finite volume algorithm. To address challenges associated with non-cartesian geometries, unique features of cylindrical phase space coordinates are described. Preliminary results of continuum kinetic simulations in 4D (r,z,v r,v z) phase space are presented.« less
NASA Astrophysics Data System (ADS)
Trandafir, Laura; Alexandru, Mioara; Constantin, Mihai; Ioniţă, Anca; Zorilă, Florina; Moise, Valentin
2012-09-01
EN ISO 11137 established regulations for setting or substantiating the dose for achieving the desired sterility assurance level. The validation studies can be designed in particular for different types of products. Each product needs distinct protocols for bioburden determination and sterility testing. The Microbiological Laboratory from Irradiation Processing Center (IRASM) deals with different types of products, mainly for the VDmax25 method. When it comes to microbiological evaluation the most challenging was cotton gauze. A special situation for establishing the sterilization validation method appears in cases of cotton packed in large quantities. The VDmax25 method cannot be applied for items with average bioburden more than 1000 CFU/pack, irrespective of the weight of the package. This is a method limitation and implies increased costs for the manufacturer when choosing other methods. For microbiological tests, culture condition should be selected in both cases of the bioburden and sterility testing. Details about choosing criteria are given.
Wodushek, Thomas R; Greher, Michael R
2017-05-01
In the first column in this 2-part series, Performance Validity Testing in Neuropsychology: Scientific Basis and Clinical Application-A Brief Review, the authors introduced performance validity tests (PVTs) and their function, provided a justification for why they are necessary, traced their ongoing endorsement by neuropsychological organizations, and described how they are used and interpreted by ever increasing numbers of clinical neuropsychologists. To enhance readers' understanding of these measures, this second column briefly describes common detection strategies used in PVTs as well as the typical methods used to validate new PVTs and determine cut scores for valid/invalid determinations. We provide a discussion of the latest research demonstrating how neuropsychologists can combine multiple PVTs in a single battery to improve sensitivity/specificity to invalid responding. Finally, we discuss future directions for the research and application of PVTs.
Li, Yan; Hughes, Jan N.; Kwok, Oi-man; Hsu, Hsien-Yuan
2012-01-01
This study investigated the construct validity of measures of teacher-student support in a sample of 709 ethnically diverse second and third grade academically at-risk students. Confirmatory factor analysis investigated the convergent and discriminant validities of teacher, child, and peer reports of teacher-student support and child conduct problems. Results supported the convergent and discriminant validity of scores on the measures. Peer reports accounted for the largest proportion of trait variance and non-significant method variance. Child reports accounted for the smallest proportion of trait variance and the largest method variance. A model with two latent factors provided a better fit to the data than a model with one factor, providing further evidence of the discriminant validity of measures of teacher-student support. Implications for research, policy, and practice are discussed. PMID:21767024
Uncertain sightings and the extinction of the Ivory-billed Woodpecker.
Solow, Andrew; Smith, Woollcott; Burgman, Mark; Rout, Tracy; Wintle, Brendan; Roberts, David
2012-02-01
The extinction of a species can be inferred from a record of its sightings. Existing methods for doing so assume that all sightings in the record are valid. Often, however, there are sightings of uncertain validity. To date, uncertain sightings have been treated in an ad hoc way, either excluding them from the record or including them as if they were certain. We developed a Bayesian method that formally accounts for such uncertain sightings. The method assumes that valid and invalid sightings follow independent Poisson processes and use noninformative prior distributions for the rate of valid sightings and for a measure of the quality of uncertain sightings. We applied the method to a recently published record of sightings of the Ivory-billed Woodpecker (Campephilus principalis). This record covers the period 1897-2010 and contains 39 sightings classified as certain and 29 classified as uncertain. The Bayes factor in favor of extinction was 4.03, which constitutes substantial support for extinction. The posterior distribution of the time of extinction has 3 main modes in 1944, 1952, and 1988. The method can be applied to sighting records of other purportedly extinct species. ©2011 Society for Conservation Biology.
Gharehbaghi, Arash; Linden, Maria
2017-10-12
This paper presents a novel method for learning the cyclic contents of stochastic time series: the deep time-growing neural network (DTGNN). The DTGNN combines supervised and unsupervised methods in different levels of learning for an enhanced performance. It is employed by a multiscale learning structure to classify cyclic time series (CTS), in which the dynamic contents of the time series are preserved in an efficient manner. This paper suggests a systematic procedure for finding the design parameter of the classification method for a one-versus-multiple class application. A novel validation method is also suggested for evaluating the structural risk, both in a quantitative and a qualitative manner. The effect of the DTGNN on the performance of the classifier is statistically validated through the repeated random subsampling using different sets of CTS, from different medical applications. The validation involves four medical databases, comprised of 108 recordings of the electroencephalogram signal, 90 recordings of the electromyogram signal, 130 recordings of the heart sound signal, and 50 recordings of the respiratory sound signal. Results of the statistical validations show that the DTGNN significantly improves the performance of the classification and also exhibits an optimal structural risk.
Rajan, Sekar; Colaco, Socorrina; Ramesh, N; Meyyanathan, Subramania Nainar; Elango, K
2014-02-01
This study describes the development and validation of dissolution tests for sustained release Dextromethorphan hydrobromide tablets using an HPLC method. Chromatographic separation was achieved on a C18 column utilizing 0.5% triethylamine (pH 7.5) and acetonitrile in the ratio of 50:50. The detection wavelength was 280 nm. The method was validated and response was found to be linear in the drug concentration range of 10-80 microg mL(-1). The suitable conditions were clearly decided after testing sink conditions, dissolution medium and agitation intensity. The most excellent dissolution conditions tested, for the Dextromethorphan hydrobromide was applied to appraise the dissolution profiles. The method was validated and response was found to be linear in the drug concentration range of 10-80 microg mL(-1). The method was established to have sufficient intermediate precision as similar separation was achieved on another instrument handled by different operators. Mean Recovery was 101.82%. Intra precisions for three different concentrations were 1.23, 1.10 0.72 and 1.57, 1.69, 0.95 and inter run precisions were % RSD 0.83, 1.36 and 1.57%, respectively. The method was successfully applied for dissolution study of the developed Dextromethorphan hydrobromide tablets.
Konda, Ravi Kumar; Chandu, Babu Rao; Challa, B.R.; Kothapalli, Chandrasekhar B.
2012-01-01
The most suitable bio-analytical method based on liquid–liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard for Rasagiline. Zorbax Eclipse Plus C18 (2.1 mm×50 mm, 3.5 μm) column provided chromatographic separation of analyte followed by detection with mass spectrometry. The method involved simple isocratic chromatographic condition and mass spectrometric detection in the positive ionization mode using an API-4000 system. The total run time was 3.0 min. The proposed method has been validated with the linear range of 5–12000 pg/mL for Rasagiline. The intra-run and inter-run precision values were within 1.3%–2.9% and 1.6%–2.2% respectively for Rasagiline. The overall recovery for Rasagiline and Rasagiline-13C3 mesylate analog was 96.9% and 96.7% respectively. This validated method was successfully applied to the bioequivalence and pharmacokinetic study of human volunteers under fasting condition. PMID:29403764
Sánchez, Raquel; Snell, James; Held, Andrea; Emons, Hendrik
2015-08-01
A simple, robust and reliable method for mercury determination in seawater matrices based on the combination of cold vapour generation and inductively coupled plasma mass spectrometry (CV-ICP-MS) and its complete in-house validation are described. The method validation covers parameters such as linearity, limit of detection (LOD), limit of quantification (LOQ), trueness, repeatability, intermediate precision and robustness. A calibration curve covering the whole working range was achieved with coefficients of determination typically higher than 0.9992. The repeatability of the method (RSDrep) was 0.5 %, and the intermediate precision was 2.3 % at the target mass fraction of 20 ng/kg. Moreover, the method was robust with respect to the salinity of the seawater. The limit of quantification was 2.7 ng/kg, which corresponds to 13.5 % of the target mass fraction in the future certified reference material (20 ng/kg). An uncertainty budget for the measurement of mercury in seawater has been established. The relative expanded (k = 2) combined uncertainty is 6 %. The performance of the validated method was demonstrated by generating results for process control and a homogeneity study for the production of a candidate certified reference material.
Sadeghi, Fahimeh; Navidpour, Latifeh; Bayat, Sima; Afshar, Minoo
2013-01-01
A green, simple, and stability-indicating RP-HPLC method was developed for the determination of diltiazem in topical preparations. The separation was based on a C18 analytical column using a mobile phase consisted of ethanol: phosphoric acid solution (pH = 2.5) (35 : 65, v/v). Column temperature was set at 50°C and quantitation was achieved with UV detection at 240 nm. In forced degradation studies, the drug was subjected to oxidation, hydrolysis, photolysis, and heat. The method was validated for specificity, selectivity, linearity, precision, accuracy, and robustness. The applied procedure was found to be linear in diltiazem concentration range of 0.5–50 μg/mL (r 2 = 0.9996). Precision was evaluated by replicate analysis in which % relative standard deviation (RSD) values for areas were found below 2.0. The recoveries obtained (99.25%–101.66%) ensured the accuracy of the developed method. The degradation products as well as the pharmaceutical excipients were well resolved from the pure drug. The expanded uncertainty (5.63%) of the method was also estimated from method validation data. Accordingly, the proposed validated and sustainable procedure was proved to be suitable for routine analyzing and stability studies of diltiazem in pharmaceutical preparations. PMID:24163778
Psychometric and cognitive validation of a social capital measurement tool in Peru and Vietnam.
De Silva, Mary J; Harpham, Trudy; Tuan, Tran; Bartolini, Rosario; Penny, Mary E; Huttly, Sharon R
2006-02-01
Social capital is a relatively new concept which has attracted significant attention in recent years. No consensus has yet been reached on how to measure social capital, resulting in a large number of different tools available. While psychometric validation methods such as factor analysis have been used by a few studies to assess the internal validity of some tools, these techniques rely on data already collected by the tool and are therefore not capable of eliciting what the questions are actually measuring. The Young Lives (YL) study includes quantitative measures of caregiver's social capital in four countries (Vietnam, Peru, Ethiopia, and India) using a short version of the Adapted Social Capital Assessment Tool (SASCAT). A range of different psychometric methods including factor analysis were used to evaluate the construct validity of SASCAT in Peru and Vietnam. In addition, qualitative cognitive interviews with 20 respondents from Peru and 24 respondents from Vietnam were conducted to explore what each question is actually measuring. We argue that psychometric validation techniques alone are not sufficient to adequately validate multi-faceted social capital tools for use in different cultural settings. Psychometric techniques show SASCAT to be a valid tool reflecting known constructs and displaying postulated links with other variables. However, results from the cognitive interviews present a more mixed picture with some questions being appropriately interpreted by respondents, and others displaying significant differences between what the researchers intended them to measure and what they actually do. Using evidence from a range of methods of assessing validity has enabled the modification of an existing instrument into a valid and low cost tool designed to measure social capital within larger surveys in Peru and Vietnam, with the potential for use in other developing countries following local piloting and cultural adaptation of the tool.
ERIC Educational Resources Information Center
Aebi, Marcel; Plattner, Belinda; Metzke, Christa Winkler; Bessler, Cornelia; Steinhausen, Hans-Christoph
2013-01-01
Background: Different dimensions of oppositional defiant disorder (ODD) have been found as valid predictors of further mental health problems and antisocial behaviors in youth. The present study aimed at testing the construct, concurrent, and predictive validity of ODD dimensions derived from parent- and self-report measures. Method: Confirmatory…
Munkácsy, Gyöngyi; Sztupinszki, Zsófia; Herman, Péter; Bán, Bence; Pénzváltó, Zsófia; Szarvas, Nóra; Győrffy, Balázs
2016-09-27
No independent cross-validation of success rate for studies utilizing small interfering RNA (siRNA) for gene silencing has been completed before. To assess the influence of experimental parameters like cell line, transfection technique, validation method, and type of control, we have to validate these in a large set of studies. We utilized gene chip data published for siRNA experiments to assess success rate and to compare methods used in these experiments. We searched NCBI GEO for samples with whole transcriptome analysis before and after gene silencing and evaluated the efficiency for the target and off-target genes using the array-based expression data. Wilcoxon signed-rank test was used to assess silencing efficacy and Kruskal-Wallis tests and Spearman rank correlation were used to evaluate study parameters. All together 1,643 samples representing 429 experiments published in 207 studies were evaluated. The fold change (FC) of down-regulation of the target gene was above 0.7 in 18.5% and was above 0.5 in 38.7% of experiments. Silencing efficiency was lowest in MCF7 and highest in SW480 cells (FC = 0.59 and FC = 0.30, respectively, P = 9.3E-06). Studies utilizing Western blot for validation performed better than those with quantitative polymerase chain reaction (qPCR) or microarray (FC = 0.43, FC = 0.47, and FC = 0.55, respectively, P = 2.8E-04). There was no correlation between type of control, transfection method, publication year, and silencing efficiency. Although gene silencing is a robust feature successfully cross-validated in the majority of experiments, efficiency remained insufficient in a significant proportion of studies. Selection of cell line model and validation method had the highest influence on silencing proficiency.
Leporace, Gustavo; Batista, Luiz Alberto; Serra Cruz, Raphael; Zeitoune, Gabriel; Cavalin, Gabriel Armondi; Metsavaht, Leonardo
2018-03-01
The purpose of this study was to test the validity of dynamic leg length discrepancy (DLLD) during gait as a radiation-free screening method for measuring anatomic leg length discrepancy (ALLD). Thirty-three subjects with mild leg length discrepancy walked along a walkway and the dynamic leg length discrepancy (DLLD) was calculated using a motion analysis system. Pearson correlation and paired Student t -tests were applied to calculate the correlation and compare the differences between DLLD and ALLD (α = 0.05). The results of our study showed DLLD is not a valid method to predict ALLD in subjects with mild limb discrepancy.
NASA Technical Reports Server (NTRS)
Price J. M.; Ortega, R.
1998-01-01
Probabilistic method is not a universally accepted approach for the design and analysis of aerospace structures. The validity of this approach must be demonstrated to encourage its acceptance as it viable design and analysis tool to estimate structural reliability. The objective of this Study is to develop a well characterized finite population of similar aerospace structures that can be used to (1) validate probabilistic codes, (2) demonstrate the basic principles behind probabilistic methods, (3) formulate general guidelines for characterization of material drivers (such as elastic modulus) when limited data is available, and (4) investigate how the drivers affect the results of sensitivity analysis at the component/failure mode level.
Tozzoli, Rosangela; Maugliani, Antonella; Michelacci, Valeria; Minelli, Fabio; Caprioli, Alfredo; Morabito, Stefano
2018-05-08
In 2006, the European Committee for standardisation (CEN)/Technical Committee 275 - Food analysis - Horizontal methods/Working Group 6 - Microbiology of the food chain (TC275/WG6), launched the project of validating the method ISO 16654:2001 for the detection of Escherichia coli O157 in foodstuff by the evaluation of its performance, in terms of sensitivity and specificity, through collaborative studies. Previously, a validation study had been conducted to assess the performance of the Method No 164 developed by the Nordic Committee for Food Analysis (NMKL), which aims at detecting E. coli O157 in food as well, and is based on a procedure equivalent to that of the ISO 16654:2001 standard. Therefore, CEN established that the validation data obtained for the NMKL Method 164 could be exploited for the ISO 16654:2001 validation project, integrated with new data obtained through two additional interlaboratory studies on milk and sprouts, run in the framework of the CEN mandate No. M381. The ISO 16654:2001 validation project was led by the European Union Reference Laboratory for Escherichia coli including VTEC (EURL-VTEC), which organized the collaborative validation study on milk in 2012 with 15 participating laboratories and that on sprouts in 2014, with 14 participating laboratories. In both studies, a total of 24 samples were tested by each laboratory. Test materials were spiked with different concentration of E. coli O157 and the 24 samples corresponded to eight replicates of three levels of contamination: zero, low and high spiking level. The results submitted by the participating laboratories were analyzed to evaluate the sensitivity and specificity of the ISO 16654:2001 method when applied to milk and sprouts. The performance characteristics calculated on the data of the collaborative validation studies run under the CEN mandate No. M381 returned sensitivity and specificity of 100% and 94.4%, respectively for the milk study. As for sprouts matrix, the sensitivity resulted in 75.9% in the low level of contamination samples and 96.4% in samples spiked with high level of E. coli O157 and specificity was calculated as 99.1%. Copyright © 2018 Elsevier B.V. All rights reserved.
Kim, Joseph; Flick, Jeanette; Reimer, Michael T; Rodila, Ramona; Wang, Perry G; Zhang, Jun; Ji, Qin C; El-Shourbagy, Tawakol A
2007-11-01
As an effective DPP-IV inhibitor, 2-(4-((2-(2S,5R)-2-Cyano-5-ethynyl-1-pyrrolidinyl)-2-oxoethylamino)-4-methyl-1-piperidinyl)-4-pyridinecarboxylic acid (ABT-279), is an investigational drug candidate under development at Abbott Laboratories for potential treatment of type 2 diabetes. In order to support the development of ABT-279, multiple analytical methods for an accurate, precise and selective concentration determination of ABT-279 in different matrices were developed and validated in accordance with the US Food and Drug Administration Guidance on Bioanalytical Method Validation. The analytical method for ABT-279 in dog plasma was validated in parallel to other validations for ABT-279 determination in different matrices. In order to shorten the sample preparation time and increase method precision, an automated multi-channel liquid handler was used to perform high-throughput protein precipitation and all other liquid transfers. The separation was performed through a Waters YMC ODS-AQ column (2.0 x 150 mm, 5 microm, 120 A) with a mobile phase of 20 mm ammonium acetate in 20% acetonitrile at a flow rate of 0.3 mL/min. Data collection started at 2.2 min and continued for 2.0 min. The validated linear dynamic range in dog plasma was between 3.05 and 2033.64 ng/mL using a 50 microL sample volume. The achieved r(2) coefficient of determination from three consecutive runs was between 0.998625 and 0.999085. The mean bias was between -4.1 and 4.3% for all calibration standards including lower limit of quantitation. The mean bias was between -8.0 and 0.4% for the quality control samples. The precision, expressed as a coefficient of variation (CV), was < or =4.1% for all levels of quality control samples. The validation results demonstrated that the high-throughput method was accurate, precise and selective for the determination of ABT-279 in dog plasma. The validated method was also employed to support two toxicology studies. The passing rate was 100% for all 49 runs from one validation study and two toxicology studies. Copyright (c) 2007 John Wiley & Sons, Ltd.
Evidence-based dentistry: analysis of dental anxiety scales for children.
Al-Namankany, A; de Souza, M; Ashley, P
2012-03-09
To review paediatric dental anxiety measures (DAMs) and assess the statistical methods used for validation and their clinical implications. A search of four computerised databases between 1960 and January 2011 associated with DAMs, using pre-specified search terms, to assess the method of validation including the reliability as intra-observer agreement 'repeatability or stability' and inter-observer agreement 'reproducibility' and all types of validity. Fourteen paediatric DAMs were predominantly validated in schools and not in the clinical setting while five of the DAMs were not validated at all. The DAMs that were validated were done so against other paediatric DAMs which may not have been validated previously. Reliability was not assessed in four of the DAMs. However, all of the validated studies assessed reliability which was usually 'good' or 'acceptable'. None of the current DAMs used a formal sample size technique. Diversity was seen between the studies ranging from a few simple pictograms to lists of questions reported by either the individual or an observer. To date there is no scale that can be considered as a gold standard, and there is a need to further develop an anxiety scale with a cognitive component for children and adolescents.
Donnan, Peter T; Symon, Andrew G; Kellett, Gillian; Monteith-Hodge, Ewa; Rauchhaus, Petra; Wyatt, Jeremy C
2012-01-01
Objective To test the reliability, validity, acceptability, and practicality of short message service (SMS) messaging for collection of research data. Materials and methods The studies were carried out in a cohort of recently delivered women in Tayside, Scotland, UK, who were asked about their current infant feeding method and future feeding plans. Reliability was assessed by comparison of their responses to two SMS messages sent 1 day apart. Validity was assessed by comparison of their responses to text questions and the same question administered by phone 1 day later, by comparison with the same data collected from other sources, and by correlation with other related measures. Acceptability was evaluated using quantitative and qualitative questions, and practicality by analysis of a researcher log. Results Reliability of the factual SMS message gave perfect agreement. Reliabilities for the numerical question were reasonable, with κ between 0.76 (95% CI 0.56 to 0.96) and 0.80 (95% CI 0.59 to 1.00). Validity for data compared with that collected by phone within 24 h (κ =0.92 (95% CI 0.84 to 1.00)) and with health visitor data (κ =0.85 (95% CI 0.73 to 0.97)) was excellent. Correlation validity between the text responses and other related demographic and clinical measures was as expected. Participants found the method a convenient and acceptable way of providing data. For researchers, SMS text messaging provided an easy and functional method of gathering a large volume of data. Conclusion In this sample and for these questions, SMS was a reliable and valid method for capturing research data. PMID:22539081
Validity and inter-observer reliability of subjective hand-arm vibration assessments.
Coenen, Pieter; Formanoy, Margriet; Douwes, Marjolein; Bosch, Tim; de Kraker, Heleen
2014-07-01
Exposure to mechanical vibrations at work (e.g., due to handling powered tools) is a potential occupational risk as it may cause upper extremity complaints. However, reliable and valid assessment methods for vibration exposure at work are lacking. Measuring hand-arm vibration objectively is often difficult and expensive, while often used information provided by manufacturers lacks detail. Therefore, a subjective hand-arm vibration assessment method was tested on validity and inter-observer reliability. In an experimental protocol, sixteen tasks handling powered tools were executed by two workers. Hand-arm vibration was assessed subjectively by 16 observers according to the proposed subjective assessment method. As a gold standard reference, hand-arm vibration was measured objectively using a vibration measurement device. Weighted κ's were calculated to assess validity, intra-class-correlation coefficients (ICCs) were calculated to assess inter-observer reliability. Inter-observer reliability of the subjective assessments depicting the agreement among observers can be expressed by an ICC of 0.708 (0.511-0.873). The validity of the subjective assessments as compared to the gold-standard reference can be expressed by a weighted κ of 0.535 (0.285-0.785). Besides, the percentage of exact agreement of the subjective assessment compared to the objective measurement was relatively low (i.e., 52% of all tasks). This study shows that subjectively assessed hand-arm vibrations are fairly reliable among observers and moderately valid. This assessment method is a first attempt to use subjective risk assessments of hand-arm vibration. Although, this assessment method can benefit from some future improvement, it can be of use in future studies and in field-based ergonomic assessments. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.
van Schaick, Willem; van Dooren, Bart T H; Mulder, Paul G H; Völker-Dieben, Hennie J M
2005-07-01
To report on the calibration of the Topcon SP-2000P specular microscope and the Endothelial Cell Analysis Module of the IMAGEnet 2000 software, and to establish the validity of the different endothelial cell density (ECD) assessment methods available in these instruments. Using an external microgrid, we calibrated the magnification of the SP-2000P and the IMAGEnet software. In both eyes of 36 volunteers, we validated 4 ECD assessment methods by comparing these methods to the gold standard manual ECD, manual counting of cells on a video print. These methods were: the estimated ECD, estimation of ECD with a reference grid on the camera screen; the SP-2000P ECD, pointing out whole contiguous cells on the camera screen; the uncorrected IMAGEnet ECD, using automatically drawn cell borders, and the corrected IMAGEnet ECD, with manual correction of incorrectly drawn cell borders in the automated analysis. Validity of each method was evaluated by calculating both the mean difference with the manual ECD and the limits of agreement as described by Bland and Altman. Preset factory values of magnification were incorrect, resulting in errors in ECD of up to 9%. All assessments except 1 of the estimated ECDs differed significantly from manual ECDs, with most differences being similar (< or =6.5%), except for uncorrected IMAGEnet ECD (30.2%). Corrected IMAGEnet ECD showed the narrowest limits of agreement (-4.9 to +19.3%). We advise checking the calibration of magnification in any specular microscope or endothelial analysis software as it may be erroneous. Corrected IMAGEnet ECD is the most valid of the investigated methods in the Topcon SP-2000P/IMAGEnet 2000 combination.
Dubey, J K; Patyal, S K; Sharma, Ajay
2018-03-19
In the present day scenario of increasing awareness and concern about the pesticides, it is very important to ensure the quality of data being generated in pesticide residue analysis. To impart confidence in the products, terms like quality assurance and quality control are used as an integral part of quality management. In order to ensure better quality of results in pesticide residue analysis, validation of analytical methods to be used is extremely important. Keeping in view the importance of validation of method, the validation of QuEChERS (quick, easy, cheap, effective, rugged, and safe) a multiresidue method for extraction of 13 organochlorines and seven synthetic pyrethroids in fruits and vegetables followed by GC ECD for quantification was done so as to use this method for analysis of samples received in the laboratory. The method has been validated as per the Guidelines issued by SANCO (French words Sante for Health and Consommateurs for Consumers) in accordance with their document SANCO/XXXX/2013. Various parameters analyzed, viz., linearity, specificity, repeatability, reproducibility, and ruggedness were found to have acceptable values with a per cent RSD of less than 10%. Limit of quantification (LOQ) for the organochlorines was established to be 0.01 and 0.05 mg kg -1 for the synthetic pyrethroids. The uncertainty of the measurement (MU) for all these compounds ranged between 1 and 10%. The matrix-match calibration was used to compensate the matrix effect on the quantification of the compounds. The overall recovery of the method ranged between 80 and 120%. These results demonstrate the applicability and acceptability of this method in routine estimation of pesticide residues of these 20 pesticides in the fruits and vegetables by the laboratory.
2013-01-01
Background In recent years response rates on telephone surveys have been declining. Rates for the behavioral risk factor surveillance system (BRFSS) have also declined, prompting the use of new methods of weighting and the inclusion of cell phone sampling frames. A number of scholars and researchers have conducted studies of the reliability and validity of the BRFSS estimates in the context of these changes. As the BRFSS makes changes in its methods of sampling and weighting, a review of reliability and validity studies of the BRFSS is needed. Methods In order to assess the reliability and validity of prevalence estimates taken from the BRFSS, scholarship published from 2004–2011 dealing with tests of reliability and validity of BRFSS measures was compiled and presented by topics of health risk behavior. Assessments of the quality of each publication were undertaken using a categorical rubric. Higher rankings were achieved by authors who conducted reliability tests using repeated test/retest measures, or who conducted tests using multiple samples. A similar rubric was used to rank validity assessments. Validity tests which compared the BRFSS to physical measures were ranked higher than those comparing the BRFSS to other self-reported data. Literature which undertook more sophisticated statistical comparisons was also ranked higher. Results Overall findings indicated that BRFSS prevalence rates were comparable to other national surveys which rely on self-reports, although specific differences are noted for some categories of response. BRFSS prevalence rates were less similar to surveys which utilize physical measures in addition to self-reported data. There is very little research on reliability and validity for some health topics, but a great deal of information supporting the validity of the BRFSS data for others. Conclusions Limitations of the examination of the BRFSS were due to question differences among surveys used as comparisons, as well as mode of data collection differences. As the BRFSS moves to incorporating cell phone data and changing weighting methods, a review of reliability and validity research indicated that past BRFSS landline only data were reliable and valid as measured against other surveys. New analyses and comparisons of BRFSS data which include the new methodologies and cell phone data will be needed to ascertain the impact of these changes on estimates in the future. PMID:23522349
Evaluation of a physically based quasi-linear and a conceptually based nonlinear Muskingum methods
NASA Astrophysics Data System (ADS)
Perumal, Muthiah; Tayfur, Gokmen; Rao, C. Madhusudana; Gurarslan, Gurhan
2017-03-01
Two variants of the Muskingum flood routing method formulated for accounting nonlinearity of the channel routing process are investigated in this study. These variant methods are: (1) The three-parameter conceptual Nonlinear Muskingum (NLM) method advocated by Gillin 1978, and (2) The Variable Parameter McCarthy-Muskingum (VPMM) method recently proposed by Perumal and Price in 2013. The VPMM method does not require rigorous calibration and validation procedures as required in the case of NLM method due to established relationships of its parameters with flow and channel characteristics based on hydrodynamic principles. The parameters of the conceptual nonlinear storage equation used in the NLM method were calibrated using the Artificial Intelligence Application (AIA) techniques, such as the Genetic Algorithm (GA), the Differential Evolution (DE), the Particle Swarm Optimization (PSO) and the Harmony Search (HS). The calibration was carried out on a given set of hypothetical flood events obtained by routing a given inflow hydrograph in a set of 40 km length prismatic channel reaches using the Saint-Venant (SV) equations. The validation of the calibrated NLM method was investigated using a different set of hypothetical flood hydrographs obtained in the same set of channel reaches used for calibration studies. Both the sets of solutions obtained in the calibration and validation cases using the NLM method were compared with the corresponding solutions of the VPMM method based on some pertinent evaluation measures. The results of the study reveal that the physically based VPMM method is capable of accounting for nonlinear characteristics of flood wave movement better than the conceptually based NLM method which requires the use of tedious calibration and validation procedures.
Rahman, Mohd Nasrull Abdol; Mohamad, Siti Shafika
2017-01-01
Computer works are associated with Musculoskeletal Disorders (MSDs). There are several methods have been developed to assess computer work risk factor related to MSDs. This review aims to give an overview of current techniques available for pen-and-paper-based observational methods in assessing ergonomic risk factors of computer work. We searched an electronic database for materials from 1992 until 2015. The selected methods were focused on computer work, pen-and-paper observational methods, office risk factors and musculoskeletal disorders. This review was developed to assess the risk factors, reliability and validity of pen-and-paper observational method associated with computer work. Two evaluators independently carried out this review. Seven observational methods used to assess exposure to office risk factor for work-related musculoskeletal disorders were identified. The risk factors involved in current techniques of pen and paper based observational tools were postures, office components, force and repetition. From the seven methods, only five methods had been tested for reliability. They were proven to be reliable and were rated as moderate to good. For the validity testing, from seven methods only four methods were tested and the results are moderate. Many observational tools already exist, but no single tool appears to cover all of the risk factors including working posture, office component, force, repetition and office environment at office workstations and computer work. Although the most important factor in developing tool is proper validation of exposure assessment techniques, the existing observational method did not test reliability and validity. Futhermore, this review could provide the researchers with ways on how to improve the pen-and-paper-based observational method for assessing ergonomic risk factors of computer work.
Cross-validation pitfalls when selecting and assessing regression and classification models.
Krstajic, Damjan; Buturovic, Ljubomir J; Leahy, David E; Thomas, Simon
2014-03-29
We address the problem of selecting and assessing classification and regression models using cross-validation. Current state-of-the-art methods can yield models with high variance, rendering them unsuitable for a number of practical applications including QSAR. In this paper we describe and evaluate best practices which improve reliability and increase confidence in selected models. A key operational component of the proposed methods is cloud computing which enables routine use of previously infeasible approaches. We describe in detail an algorithm for repeated grid-search V-fold cross-validation for parameter tuning in classification and regression, and we define a repeated nested cross-validation algorithm for model assessment. As regards variable selection and parameter tuning we define two algorithms (repeated grid-search cross-validation and double cross-validation), and provide arguments for using the repeated grid-search in the general case. We show results of our algorithms on seven QSAR datasets. The variation of the prediction performance, which is the result of choosing different splits of the dataset in V-fold cross-validation, needs to be taken into account when selecting and assessing classification and regression models. We demonstrate the importance of repeating cross-validation when selecting an optimal model, as well as the importance of repeating nested cross-validation when assessing a prediction error.
Humble, Emily; Thorne, Michael A S; Forcada, Jaume; Hoffman, Joseph I
2016-08-26
Single nucleotide polymorphism (SNP) discovery is an important goal of many studies. However, the number of 'putative' SNPs discovered from a sequence resource may not provide a reliable indication of the number that will successfully validate with a given genotyping technology. For this it may be necessary to account for factors such as the method used for SNP discovery and the type of sequence data from which it originates, suitability of the SNP flanking sequences for probe design, and genomic context. To explore the relative importance of these and other factors, we used Illumina sequencing to augment an existing Roche 454 transcriptome assembly for the Antarctic fur seal (Arctocephalus gazella). We then mapped the raw Illumina reads to the new hybrid transcriptome using BWA and BOWTIE2 before calling SNPs with GATK. The resulting markers were pooled with two existing sets of SNPs called from the original 454 assembly using NEWBLER and SWAP454. Finally, we explored the extent to which SNPs discovered using these four methods overlapped and predicted the corresponding validation outcomes for both Illumina Infinium iSelect HD and Affymetrix Axiom arrays. Collating markers across all discovery methods resulted in a global list of 34,718 SNPs. However, concordance between the methods was surprisingly poor, with only 51.0 % of SNPs being discovered by more than one method and 13.5 % being called from both the 454 and Illumina datasets. Using a predictive modeling approach, we could also show that SNPs called from the Illumina data were on average more likely to successfully validate, as were SNPs called by more than one method. Above and beyond this pattern, predicted validation outcomes were also consistently better for Affymetrix Axiom arrays. Our results suggest that focusing on SNPs called by more than one method could potentially improve validation outcomes. They also highlight possible differences between alternative genotyping technologies that could be explored in future studies of non-model organisms.
Abu El-Enin, Mohammed Abu Bakr; Al-Ghaffar Hammouda, Mohammed El-Sayed Abd; El-Sherbiny, Dina Tawfik; El-Wasseef, Dalia Rashad; El-Ashry, Saadia Mahmoud
2016-02-01
A valid, sensitive and rapid spectrofluorimetric method has been developed and validated for determination of both tadalafil (TAD) and vardenafil (VAR) either in their pure form, in their tablet dosage forms or spiked in human plasma. This method is based on measurement of the native fluorescence of both drugs in acetonitrile at λem 330 and 470 nm after excitation at 280 and 275 nm for tadalafil and vardenafil, respectively. Linear relationships were obtained over the concentration range 4-40 and 10-250 ng/mL with a minimum detection of 1 and 3 ng/mL for tadalafil and vardenafil, respectively. Various experimental parameters affecting the fluorescence intensity were carefully studied and optimized. The developed method was applied successfully for the determination of tadalafil and vardenafil in bulk drugs and tablet dosage forms. Moreover, the high sensitivity of the proposed method permitted their determination in spiked human plasma. The developed method was validated in terms of specificity, linearity, lower limit of quantification (LOQ), lower limit of detection (LOD), precision and accuracy. The mean recoveries of the analytes in pharmaceutical preparations were in agreement with those obtained from the comparison methods, as revealed by statistical analysis of the obtained results using Student's t-test and the variance ratio F-test. Copyright © 2015 John Wiley & Sons, Ltd.
Martins, Danielly da Fonte Carvalho; Florindo, Lorena Coimbra; Machado, Anna Karolina Mouzer da Silva; Todeschini, Vítor; Sangoi, Maximiliano da Silva
2017-11-01
This study presents the development and validation of UV spectrophotometric methods for the determination of pinaverium bromide (PB) in tablet assay and dissolution studies. The methods were satisfactorily validated according to International Conference on Harmonization guidelines. The response was linear (r2 > 0.99) in the concentration ranges of 2-14 μg/mL at 213 nm and 10-70 μg/mL at 243 nm. The LOD and LOQ were 0.39 and 1.31 μg/mL, respectively, at 213 nm. For the 243 nm method, the LOD and LOQ were 2.93 and 9.77 μg/mL, respectively. Precision was evaluated by RSD, and the obtained results were lower than 2%. Adequate accuracy was also obtained. The methods proved to be robust using a full factorial design evaluation. For PB dissolution studies, the best conditions were achieved using a United States Pharmacopeia Dissolution Apparatus 2 (paddle) at 50 rpm and with 900 mL 0.1 M hydrochloric acid as the dissolution medium, presenting satisfactory results during the validation tests. In addition, the kinetic parameters of drug release were investigated using model-dependent methods, and the dissolution profiles were best described by the first-order model. Therefore, the proposed methods were successfully applied for the assay and dissolution analysis of PB in commercial tablets.
Fischedick, Justin T; Glas, Ronald; Hazekamp, Arno; Verpoorte, Rob
2009-01-01
Cannabis and cannabinoid based medicines are currently under serious investigation for legitimate development as medicinal agents, necessitating new low-cost, high-throughput analytical methods for quality control. The goal of this study was to develop and validate, according to ICH guidelines, a simple rapid HPTLC method for the quantification of Delta(9)-tetrahydrocannabinol (Delta(9)-THC) and qualitative analysis of other main neutral cannabinoids found in cannabis. The method was developed and validated with the use of pure cannabinoid reference standards and two medicinal cannabis cultivars. Accuracy was determined by comparing results obtained from the HTPLC method with those obtained from a validated HPLC method. Delta(9)-THC gives linear calibration curves in the range of 50-500 ng at 206 nm with a linear regression of y = 11.858x + 125.99 and r(2) = 0.9968. Results have shown that the HPTLC method is reproducible and accurate for the quantification of Delta(9)-THC in cannabis. The method is also useful for the qualitative screening of the main neutral cannabinoids found in cannabis cultivars.
Castro-Vega, Iciar; Veses Martín, Silvia; Cantero Llorca, Juana; Barrios Marta, Cristina; Bañuls, Celia; Hernández-Mijares, Antonio
2018-03-09
Nutritional screening allows for the detection of nutritional risk. Validated tools should be implemented, and their usefulness should be contrasted with a gold standard. The aim of this study is to discover the validity, efficacy and reliability of 3 nutritional screening tools in relation to complete nutritional assessment. A sub-analysis of a cross-sectional and descriptive study on the prevalence of disease-related malnutrition. The sample was selected from outpatients, hospitalized and institutionalized patients. MUST, MNAsf and MST screening were employed. A nutritional assessment of all the patients was undertaken. The SENPE-SEDOM consensus was used for the diagnosis. In the outpatients, both MUST and MNAsf have a similar validity in relation to the nutritional assessment (AUC 0.871 and 0.883, respectively). In the institutionalized patients, the MUST screening method is the one that shows the greatest validity (AUC 0.815), whereas in the hospitalized patients, the most valid methods are both MUST and MST (AUC 0.868 and 0.853, respectively). It is essential to use nutritional screening to invest the available resources wisely. Based on our results, MUST is the most suitable screening method in hospitalized and institutionalized patients. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.
Validation of a Russian Language Oswestry Disability Index Questionnaire.
Yu, Elizabeth M; Nosova, Emily V; Falkenstein, Yuri; Prasad, Priya; Leasure, Jeremi M; Kondrashov, Dimitriy G
2016-11-01
Study Design Retrospective reliability and validity study. Objective To validate a recently translated Russian language version of the Oswestry Disability Index (R-ODI) using standardized methods detailed from previous validations in other languages. Methods We included all subjects who were seen in our spine surgery clinic, over the age of 18, and fluent in the Russian language. R-ODI was translated by six bilingual people and combined into a consensus version. R-ODI and visual analog scale (VAS) questionnaires for leg and back pain were distributed to subjects during both their initial and follow-up visits. Test validity, stability, and internal consistency were measured using standardized psychometric methods. Results Ninety-seven subjects participated in the study. No change in the meaning of the questions on R-ODI was noted with translation from English to Russian. There was a significant positive correlation between R-ODI and VAS scores for both the leg and back during both the initial and follow-up visits ( p < 0.01 for all). The instrument was shown to have high internal consistency (Cronbach α = 0.82) and moderate test-retest stability (interclass correlation coefficient = 0.70). Conclusions The R-ODI is both valid and reliable for use among the Russian-speaking population in the United States.
2017-01-01
Background The Information Assessment Method (IAM) allows clinicians to report the cognitive impact, clinical relevance, intention to use, and expected patient health benefits associated with clinical information received by email. More than 15,000 Canadian physicians and pharmacists use the IAM in continuing education programs. In addition, information providers can use IAM ratings and feedback comments from clinicians to improve their products. Objective Our general objective was to validate the IAM questionnaire for the delivery of educational material (ecological and logical content validity). Our specific objectives were to measure the relevance and evaluate the representativeness of IAM items for assessing information received by email. Methods A 3-part mixed methods study was conducted (convergent design). In part 1 (quantitative longitudinal study), the relevance of IAM items was measured. Participants were 5596 physician members of the Canadian Medical Association who used the IAM. A total of 234,196 ratings were collected in 2012. The relevance of IAM items with respect to their main construct was calculated using descriptive statistics (relevance ratio R). In part 2 (qualitative descriptive study), the representativeness of IAM items was evaluated. A total of 15 family physicians completed semistructured face-to-face interviews. For each construct, we evaluated the representativeness of IAM items using a deductive-inductive thematic qualitative data analysis. In part 3 (mixing quantitative and qualitative parts), results from quantitative and qualitative analyses were reviewed, juxtaposed in a table, discussed with experts, and integrated. Thus, our final results are derived from the views of users (ecological content validation) and experts (logical content validation). Results Of the 23 IAM items, 21 were validated for content, while 2 were removed. In part 1 (quantitative results), 21 items were deemed relevant, while 2 items were deemed not relevant (R=4.86% [N=234,196] and R=3.04% [n=45,394], respectively). In part 2 (qualitative results), 22 items were deemed representative, while 1 item was not representative. In part 3 (mixing quantitative and qualitative results), the content validity of 21 items was confirmed, and the 2 nonrelevant items were excluded. A fully validated version was generated (IAM-v2014). Conclusions This study produced a content validated IAM questionnaire that is used by clinicians and information providers to assess the clinical information delivered in continuing education programs. PMID:28292738
New Sentinel-2 radiometric validation approaches (SEOM program)
NASA Astrophysics Data System (ADS)
Bruniquel, Véronique; Lamquin, Nicolas; Ferron, Stéphane; Govaerts, Yves; Woolliams, Emma; Dilo, Arta; Gascon, Ferran
2016-04-01
SEOM is an ESA program element whose one of the objectives aims at launching state-of-the-art studies for the scientific exploitation of operational missions. In the frame of this program, ESA awarded ACRI-ST and its partners Rayference and National Physical Laboratory (NPL) early 2016 for a R&D study on the development and intercomparison of algorithms for validating the Sentinel-2 radiometric L1 data products beyond the baseline algorithms used operationally in the frame of the S2 Mission Performance Centre. In this context, several algorithms have been proposed and are currently in development: The first one is based on the exploitation of Deep Convective Cloud (DCC) observations over ocean. This method allows an inter-band radiometry validation from the blue to the NIR (typically from B1 to B8a) from a reference band already validated for example with the well-known Rayleigh method. Due to their physical properties, DCCs appear from the remote sensing point of view to have bright and cold tops and they can be used as invariant targets to monitor the radiometric response degradation of reflective solar bands. The DCC approach is statistical i.e. the method shall be applied on a large number of measurements to derive reliable statistics and decrease the impact of the perturbing contributors. The second radiometric validation method is based on the exploitation of matchups combining both concomitant in-situ measurements and Sentinel-2 observations. The in-situ measurements which are used here correspond to measurements acquired in the frame of the RadCalNet networks. The validation is performed for the Sentinel-2 bands similar to the bands of the instruments equipping the validation site. The measurements from the Cimel CE 318 12-filters BRDF Sun Photometer installed recently in the Gobabeb site near the Namib desert are used for this method. A comprehensive verification of the calibration requires an analysis of MSI radiances over the full dynamic range, including low radiances, as extreme values are more subject to instrument response non-linearity. The third method developed in the frame of this project aims to address this point. It is based on a comparison of Sentinel-2 observations over coastal waters which have low radiometry and corresponding Radiative Transfer (RT) simulations using AERONET-OC measurements. Finally, a last method is developed using RadCalNet measurements and Sentinel-2 observations to validate the radiometry of mid/low resolution sensors such as Sentinel-3/OLCI. The RadCalNet measurements are transferred from the RadCalNet sites to Pseudo Invariant Calibration Sites (PICS) using Sentinel-2, and then these larger sites are used to validate mid- and low-resolution sensors to the RadCalNet reference. For all the developed methods, an uncertainty budget is derived following QA4EO guidelines. A last step of this ESA project is dedicated to an Inter-comparison Workshop open to entities involved in Sentinel-2 radiometric validation activities. Blind inter-comparison tests over a series of images will be proposed and the results will be discussed during the workshop.
The report describes the development and validation of a method for measuring exempt volatile organic compounds (VOCs) and carbon dioxide in consumer products. (NOTE: Ground-level ozone can cause a variety of adverse health effects as well as agricultural and ecological damage. C...
Validity Argument for Assessing L2 Pragmatics in Interaction Using Mixed Methods
ERIC Educational Resources Information Center
Youn, Soo Jung
2015-01-01
This study investigates the validity of assessing L2 pragmatics in interaction using mixed methods, focusing on the evaluation inference. Open role-plays that are meaningful and relevant to the stakeholders in an English for Academic Purposes context were developed for classroom assessment. For meaningful score interpretations and accurate…
USDA-ARS?s Scientific Manuscript database
Current methods for assessing children's dietary intake, such as interviewer-administered 24-h dietary recall (24-h DR), are time consuming and resource intensive. Self-administered instruments offer a low-cost diet assessment method for use with children. The present study assessed the validity of ...
Two-Method Planned Missing Designs for Longitudinal Research
ERIC Educational Resources Information Center
Garnier-Villarreal, Mauricio; Rhemtulla, Mijke; Little, Todd D.
2014-01-01
We examine longitudinal extensions of the two-method measurement design, which uses planned missingness to optimize cost-efficiency and validity of hard-to-measure constructs. These designs use a combination of two measures: a "gold standard" that is highly valid but expensive to administer, and an inexpensive (e.g., survey-based)…
The Arthroscopic Surgical Skill Evaluation Tool (ASSET).
Koehler, Ryan J; Amsdell, Simon; Arendt, Elizabeth A; Bisson, Leslie J; Braman, Jonathan P; Bramen, Jonathan P; Butler, Aaron; Cosgarea, Andrew J; Harner, Christopher D; Garrett, William E; Olson, Tyson; Warme, Winston J; Nicandri, Gregg T
2013-06-01
Surgeries employing arthroscopic techniques are among the most commonly performed in orthopaedic clinical practice; however, valid and reliable methods of assessing the arthroscopic skill of orthopaedic surgeons are lacking. The Arthroscopic Surgery Skill Evaluation Tool (ASSET) will demonstrate content validity, concurrent criterion-oriented validity, and reliability when used to assess the technical ability of surgeons performing diagnostic knee arthroscopic surgery on cadaveric specimens. Cross-sectional study; Level of evidence, 3. Content validity was determined by a group of 7 experts using the Delphi method. Intra-articular performance of a right and left diagnostic knee arthroscopic procedure was recorded for 28 residents and 2 sports medicine fellowship-trained attending surgeons. Surgeon performance was assessed by 2 blinded raters using the ASSET. Concurrent criterion-oriented validity, interrater reliability, and test-retest reliability were evaluated. Content validity: The content development group identified 8 arthroscopic skill domains to evaluate using the ASSET. Concurrent criterion-oriented validity: Significant differences in the total ASSET score (P < .05) between novice, intermediate, and advanced experience groups were identified. Interrater reliability: The ASSET scores assigned by each rater were strongly correlated (r = 0.91, P < .01), and the intraclass correlation coefficient between raters for the total ASSET score was 0.90. Test-retest reliability: There was a significant correlation between ASSET scores for both procedures attempted by each surgeon (r = 0.79, P < .01). The ASSET appears to be a useful, valid, and reliable method for assessing surgeon performance of diagnostic knee arthroscopic surgery in cadaveric specimens. Studies are ongoing to determine its generalizability to other procedures as well as to the live operating room and other simulated environments.
Benej, Martin; Bendlova, Bela; Vaclavikova, Eliska; Poturnajova, Martina
2011-10-06
Reliable and effective primary screening of mutation carriers is the key condition for common diagnostic use. The objective of this study is to validate the method high resolution melting (HRM) analysis for routine primary mutation screening and accomplish its optimization, evaluation and validation. Due to their heterozygous nature, germline point mutations of c-RET proto-oncogene, associated to multiple endocrine neoplasia type 2 (MEN2), are suitable for HRM analysis. Early identification of mutation carriers has a major impact on patients' survival due to early onset of medullary thyroid carcinoma (MTC) and resistance to conventional therapy. The authors performed a series of validation assays according to International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use (ICH) guidelines for validation of analytical procedures, along with appropriate design and optimization experiments. After validated evaluation of HRM, the method was utilized for primary screening of 28 pathogenic c-RET mutations distributed among nine exons of c-RET gene. Validation experiments confirm the repeatability, robustness, accuracy and reproducibility of HRM. All c-RET gene pathogenic variants were detected with no occurrence of false-positive/false-negative results. The data provide basic information about design, establishment and validation of HRM for primary screening of genetic variants in order to distinguish heterozygous point mutation carriers among the wild-type sequence carriers. HRM analysis is a powerful and reliable tool for rapid and cost-effective primary screening, e.g., of c-RET gene germline and/or sporadic mutations and can be used as a first line potential diagnostic tool.
The Role of Simulation in Microsurgical Training.
Evgeniou, Evgenios; Walker, Harriet; Gujral, Sameer
Simulation has been established as an integral part of microsurgical training. The aim of this study was to assess and categorize the various simulation models in relation to the complexity of the microsurgical skill being taught and analyze the assessment methods commonly employed in microsurgical simulation training. Numerous courses have been established using simulation models. These models can be categorized, according to the level of complexity of the skill being taught, into basic, intermediate, and advanced. Microsurgical simulation training should be assessed using validated assessment methods. Assessment methods vary significantly from subjective expert opinions to self-assessment questionnaires and validated global rating scales. The appropriate assessment method should carefully be chosen based on the simulation modality. Simulation models should be validated, and a model with appropriate fidelity should be chosen according to the microsurgical skill being taught. Assessment should move from traditional simple subjective evaluations of trainee performance to validated tools. Future studies should assess the transferability of skills gained during simulation training to the real-life setting. Copyright © 2018 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
PRO development: rigorous qualitative research as the crucial foundation.
Lasch, Kathryn Eilene; Marquis, Patrick; Vigneux, Marc; Abetz, Linda; Arnould, Benoit; Bayliss, Martha; Crawford, Bruce; Rosa, Kathleen
2010-10-01
Recently published articles have described criteria to assess qualitative research in the health field in general, but very few articles have delineated qualitative methods to be used in the development of Patient-Reported Outcomes (PROs). In fact, how PROs are developed with subject input through focus groups and interviews has been given relatively short shrift in the PRO literature when compared to the plethora of quantitative articles on the psychometric properties of PROs. If documented at all, most PRO validation articles give little for the reader to evaluate the content validity of the measures and the credibility and trustworthiness of the methods used to develop them. Increasingly, however, scientists and authorities want to be assured that PRO items and scales have meaning and relevance to subjects. This article was developed by an international, interdisciplinary group of psychologists, psychometricians, regulatory experts, a physician, and a sociologist. It presents rigorous and appropriate qualitative research methods for developing PROs with content validity. The approach described combines an overarching phenomenological theoretical framework with grounded theory data collection and analysis methods to yield PRO items and scales that have content validity.
Dozier, Samantha; Brown, Jeffrey; Currie, Alistair
2011-11-29
In recent years, technologically advanced high-throughput techniques have been developed that replace, reduce or refine animal use in vaccine quality control tests. Following validation, these tests are slowly being accepted for use by international regulatory authorities. Because regulatory acceptance itself has not guaranteed that approved humane methods are adopted by manufacturers, various organizations have sought to foster the preferential use of validated non-animal methods by interfacing with industry and regulatory authorities. After noticing this gap between regulation and uptake by industry, we began developing a paradigm that seeks to narrow the gap and quicken implementation of new replacement, refinement or reduction guidance. A systematic analysis of our experience in promoting the transparent implementation of validated non-animal vaccine potency assays has led to the refinement of our paradigmatic process, presented here, by which interested parties can assess the local regulatory acceptance of methods that reduce animal use and integrate them into quality control testing protocols, or ensure the elimination of peripheral barriers to their use, particularly for potency and other tests carried out on production batches.
Silva, Simone Alves da; Sampaio, Geni Rodrigues; Torres, Elizabeth Aparecida Ferraz da Silva
2017-04-15
Among the different food categories, the oils and fats are important sources of exposure to polycyclic aromatic hydrocarbons (PAHs), a group of organic chemical contaminants. The use of a validated method is essential to obtain reliable analytical results since the legislation establishes maximum limits in different foods. The objective of this study was to optimize and validate a method for the quantification of four PAHs [benzo(a)anthracene, chrysene, benzo(b)fluoranthene, benzo(a)pyrene] in vegetable oils. The samples were submitted to liquid-liquid extraction, followed by solid-phase extraction, and analyzed by ultra-high performance liquid chromatography. Under the optimized conditions, the validation parameters were evaluated according to the INMETRO Guidelines: linearity (r2 >0.99), selectivity (no matrix interference), limits of detection (0.08-0.30μgkg -1 ) and quantification (0.25-1.00μgkg -1 ), recovery (80.13-100.04%), repeatability and intermediate precision (<10% RSD). The method was found to be adequate for routine analysis of PAHs in the vegetable oils evaluated. Copyright © 2016. Published by Elsevier Ltd.
PRO development: rigorous qualitative research as the crucial foundation
Marquis, Patrick; Vigneux, Marc; Abetz, Linda; Arnould, Benoit; Bayliss, Martha; Crawford, Bruce; Rosa, Kathleen
2010-01-01
Recently published articles have described criteria to assess qualitative research in the health field in general, but very few articles have delineated qualitative methods to be used in the development of Patient-Reported Outcomes (PROs). In fact, how PROs are developed with subject input through focus groups and interviews has been given relatively short shrift in the PRO literature when compared to the plethora of quantitative articles on the psychometric properties of PROs. If documented at all, most PRO validation articles give little for the reader to evaluate the content validity of the measures and the credibility and trustworthiness of the methods used to develop them. Increasingly, however, scientists and authorities want to be assured that PRO items and scales have meaning and relevance to subjects. This article was developed by an international, interdisciplinary group of psychologists, psychometricians, regulatory experts, a physician, and a sociologist. It presents rigorous and appropriate qualitative research methods for developing PROs with content validity. The approach described combines an overarching phenomenological theoretical framework with grounded theory data collection and analysis methods to yield PRO items and scales that have content validity. PMID:20512662
Aguirre-Junco, Angel-Ricardo; Colombet, Isabelle; Zunino, Sylvain; Jaulent, Marie-Christine; Leneveut, Laurence; Chatellier, Gilles
2004-01-01
The initial step for the computerization of guidelines is the knowledge specification from the prose text of guidelines. We describe a method of knowledge specification based on a structured and systematic analysis of text allowing detailed specification of a decision tree. We use decision tables to validate the decision algorithm and decision trees to specify and represent this algorithm, along with elementary messages of recommendation. Edition tools are also necessary to facilitate the process of validation and workflow between expert physicians who will validate the specified knowledge and computer scientist who will encode the specified knowledge in a guide-line model. Applied to eleven different guidelines issued by an official agency, the method allows a quick and valid computerization and integration in a larger decision support system called EsPeR (Personalized Estimate of Risks). The quality of the text guidelines is however still to be developed further. The method used for computerization could help to define a framework usable at the initial step of guideline development in order to produce guidelines ready for electronic implementation.
Overview of Heat Addition and Efficiency Predictions for an Advanced Stirling Convertor
NASA Technical Reports Server (NTRS)
Wilson, Scott D.; Reid, Terry; Schifer, Nicholas; Briggs, Maxwell
2011-01-01
Past methods of predicting net heat input needed to be validated. Validation effort pursued with several paths including improving model inputs, using test hardware to provide validation data, and validating high fidelity models. Validation test hardware provided direct measurement of net heat input for comparison to predicted values. Predicted value of net heat input was 1.7 percent less than measured value and initial calculations of measurement uncertainty were 2.1 percent (under review). Lessons learned during validation effort were incorporated into convertor modeling approach which improved predictions of convertor efficiency.
Sato, Tamaki; Miyamoto, Iori; Uemura, Masako; Nakatani, Tadashi; Kakutani, Naoya; Yamano, Tetsuo
2016-01-01
A validation study was carried out on a rapid method for the simultaneous determination of pesticide residues in vegetables and fruits by LC-MS/MS. Preparation of the test solution was performed by a solid-phase extraction technique with QuEChERS (STQ method). Pesticide residues were extracted with acetonitrile using a homogenizer, followed by salting-out and dehydration at the same time. The acetonitrile layer was purified with C18 and PSA mini-columns. The method was assessed for 130 pesticide residues in 14 kinds of vegetables and fruits at the concentration level of 0.01 μg/g according to the method validation guideline of the Ministry of Health, Labour and Welfare of Japan. As a result 75 to 120 pesticide residues were determined satisfactorily in the tested samples. Thus, this method could be useful for a rapid and simultaneous determination of multi-class pesticide residues in various vegetables and fruits.
A review of MRI evaluation of demyelination in cuprizone murine model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krutenkova, E., E-mail: len--k@yandex.ru; Pan, E.; Khodanovich, M., E-mail: khodanovich@mail.tsu.ru
The cuprizone mouse model of non-autoimmune demyelination reproduces some phenomena of multiple sclerosis and is appropriate for validation and specification of a new method of non-invasive diagnostics. In the review new data which are collected using the new MRI method are compared with one or more conventional MRI tools. Also the paper reviewed the validation of MRI approaches using histological or immunohistochemical methods. Luxol fast blue histological staining and myelin basic protein immunostaining is widespread. To improve the accuracy of non-invasive conventional MRI, multimodal scanning could be applied. The new quantitative MRI method of fast mapping of the macromolecular protonmore » fraction is a reliable biomarker of myelin in the brain and can be used for research of demyelination in animals. To date, a validation of MPF method on the CPZ mouse model of demyelination is not performed, although this method is probably the best way to evaluate demyelination using MRI.« less
Fractal Clustering and Knowledge-driven Validation Assessment for Gene Expression Profiling.
Wang, Lu-Yong; Balasubramanian, Ammaiappan; Chakraborty, Amit; Comaniciu, Dorin
2005-01-01
DNA microarray experiments generate a substantial amount of information about the global gene expression. Gene expression profiles can be represented as points in multi-dimensional space. It is essential to identify relevant groups of genes in biomedical research. Clustering is helpful in pattern recognition in gene expression profiles. A number of clustering techniques have been introduced. However, these traditional methods mainly utilize shape-based assumption or some distance metric to cluster the points in multi-dimension linear Euclidean space. Their results shows poor consistence with the functional annotation of genes in previous validation study. From a novel different perspective, we propose fractal clustering method to cluster genes using intrinsic (fractal) dimension from modern geometry. This method clusters points in such a way that points in the same clusters are more self-affine among themselves than to the points in other clusters. We assess this method using annotation-based validation assessment for gene clusters. It shows that this method is superior in identifying functional related gene groups than other traditional methods.
Wang, Zhenyu; Li, Shiming; Ferguson, Stephen; Goodnow, Robert; Ho, Chi-Tang
2008-01-01
Polymethoxyflavones (PMFs), which exist exclusively in the citrus genus, have biological activities including anti-inflammatory, anticarcinogenic, and antiatherogenic properties. A validated RPLC method was developed for quantitative analysis of six major PMFs, namely nobiletin, tangeretin, sinensetin, 5,6,7,4'-tetramethoxyflavone, 3,5,6,7,3',4'-hexamethoxyflavone, and 3,5,6,7,8,3',4'-heptamethoxyflavone. The polar embedded LC stationary phase was able to fully resolve the six analogues. The developed method was fully validated in terms of linearity, accuracy, precision, sensitivity, and system suitability. The LOD of the method was calculated as 0.15 microg/mL and the recovery rate was between 97.0 and 105.1%. This analytical method was successfully applied to quantify the individual PMFs in four commercially available citrus peel extracts (CPEs). Each extract shows significant difference in the PMF composition and concentration. This method may provide a simple, rapid, and reliable tool to help reveal the correlation between the bioactivity of the PMF extracts and the individual PMF content.
Mendez, Michelle A.; Popkin, Barry M.; Buckland, Genevieve; Schroder, Helmut; Amiano, Pilar; Barricarte, Aurelio; Huerta, José-María; Quirós, José R.; Sánchez, María-José; González, Carlos A
2011-01-01
Misreporting characterized by the reporting of implausible energy intakes may undermine the valid estimation of diet-disease relations, but the methods to best identify and account for misreporting are unknown. The present study compared how alternate approaches affected associations between selected dietary factors and body mass index (BMI) by using data from the European Prospective Investigation Into Cancer and Nutrition-Spain. A total of 24,332 women and 15,061 men 29–65 years of age recruited from 1992 to 1996 for whom measured height and weight and validated diet history data were available were included. Misreporters were identified on the basis of disparities between reported energy intakes and estimated requirements calculated using the original Goldberg method and 2 alternatives: one that substituted basal metabolic rate equations that are more valid at higher BMIs and another that used doubly labeled water-predicted total energy expenditure equations. Compared with results obtained using the original method, underreporting was considerably lower and overreporting higher with alternative methods, which were highly concordant. Accounting for misreporters with all methods yielded diet-BMI relations that were more consistent with expectations; alternative methods often strengthened associations. For example, among women, multivariable-adjusted differences in BMI for the highest versus lowest vegetable intake tertile (β = 0.37 (standard error, 0.07)) were neutral after adjusting with the original method (β = 0.01 (standard error, 07)) and negative using the predicted total energy expenditure method with stringent cutoffs (β = −0.15 (standard error, 0.07)). Alternative methods may yield more valid associations between diet and obesity-related outcomes. PMID:21242302
Mendez, Michelle A; Popkin, Barry M; Buckland, Genevieve; Schroder, Helmut; Amiano, Pilar; Barricarte, Aurelio; Huerta, José-María; Quirós, José R; Sánchez, María-José; González, Carlos A
2011-02-15
Misreporting characterized by the reporting of implausible energy intakes may undermine the valid estimation of diet-disease relations, but the methods to best identify and account for misreporting are unknown. The present study compared how alternate approaches affected associations between selected dietary factors and body mass index (BMI) by using data from the European Prospective Investigation Into Cancer and Nutrition-Spain. A total of 24,332 women and 15,061 men 29-65 years of age recruited from 1992 to 1996 for whom measured height and weight and validated diet history data were available were included. Misreporters were identified on the basis of disparities between reported energy intakes and estimated requirements calculated using the original Goldberg method and 2 alternatives: one that substituted basal metabolic rate equations that are more valid at higher BMIs and another that used doubly labeled water-predicted total energy expenditure equations. Compared with results obtained using the original method, underreporting was considerably lower and overreporting higher with alternative methods, which were highly concordant. Accounting for misreporters with all methods yielded diet-BMI relations that were more consistent with expectations; alternative methods often strengthened associations. For example, among women, multivariable-adjusted differences in BMI for the highest versus lowest vegetable intake tertile (β = 0.37 (standard error, 0.07)) were neutral after adjusting with the original method (β = 0.01 (standard error, 07)) and negative using the predicted total energy expenditure method with stringent cutoffs (β = -0.15 (standard error, 0.07)). Alternative methods may yield more valid associations between diet and obesity-related outcomes.
A user-targeted synthesis of the VALUE perfect predictor experiment
NASA Astrophysics Data System (ADS)
Maraun, Douglas; Widmann, Martin; Gutierrez, Jose; Kotlarski, Sven; Hertig, Elke; Wibig, Joanna; Rössler, Ole; Huth, Radan
2016-04-01
VALUE is an open European network to validate and compare downscaling methods for climate change research. A key deliverable of VALUE is the development of a systematic validation framework to enable the assessment and comparison of both dynamical and statistical downscaling methods. VALUE's main approach to validation is user-focused: starting from a specific user problem, a validation tree guides the selection of relevant validation indices and performance measures. We consider different aspects: (1) marginal aspects such as mean, variance and extremes; (2) temporal aspects such as spell length characteristics; (3) spatial aspects such as the de-correlation length of precipitation extremes; and multi-variate aspects such as the interplay of temperature and precipitation or scale-interactions. Several experiments have been designed to isolate specific points in the downscaling procedure where problems may occur. Experiment 1 (perfect predictors): what is the isolated downscaling skill? How do statistical and dynamical methods compare? How do methods perform at different spatial scales? Experiment 2 (Global climate model predictors): how is the overall representation of regional climate, including errors inherited from global climate models? Experiment 3 (pseudo reality): do methods fail in representing regional climate change? Here, we present a user-targeted synthesis of the results of the first VALUE experiment. In this experiment, downscaling methods are driven with ERA-Interim reanalysis data to eliminate global climate model errors, over the period 1979-2008. As reference data we use, depending on the question addressed, (1) observations from 86 meteorological stations distributed across Europe; (2) gridded observations at the corresponding 86 locations or (3) gridded spatially extended observations for selected European regions. With more than 40 contributing methods, this study is the most comprehensive downscaling inter-comparison project so far. The results clearly indicate that for several aspects, the downscaling skill varies considerably between different methods. For specific purposes, some methods can therefore clearly be excluded.
Schechtman, Leonard M
2002-01-01
Toxicological testing in the current regulatory environment is steeped in a history of using animals to answer questions about the safety of products to which humans are exposed. That history forms the basis for the testing strategies that have evolved to satisfy the needs of the regulatory bodies that render decisions that affect, for the most part, virtually all phases of premarket product development and evaluation and, to a lesser extent, postmarketing surveillance. Only relatively recently have the levels of awareness of, and responsiveness to, animal welfare issues reached current proportions. That paradigm shift, although sluggish, has nevertheless been progressive. New and alternative toxicological methods for hazard evaluation and risk assessment have now been adopted and are being viewed as a means to address those issues in a manner that considers humane treatment of animals yet maintains scientific credibility and preserves the goal of ensuring human safety. To facilitate this transition, regulatory agencies and regulated industry must work together toward improved approaches. They will need assurance that the methods will be reliable and the results comparable with, or better than, those derived from the current classical methods. That confidence will be a function of the scientific validation and resultant acceptance of any given method. In the United States, to fulfill this need, the Interagency Coordinating Committee on the Validation of Alternative Methods (ICCVAM) and its operational center, the National Toxicology Program Interagency Center for the Evaluation of Alternative Toxicological Methods (NICEATM), have been constituted as prescribed in federal law. Under this mandate, ICCVAM has developed a process and established criteria for the scientific validation and regulatory acceptance of new and alternative methods. The role of ICCVAM in the validation and acceptance process and the criteria instituted toward that end are described. Also discussed are the participation of the US Food and Drug Administration (FDA) in the ICCVAM process and that agency's approach to the application and implementation of ICCVAM-recommended methods.
Climate change vulnerability for species-Assessing the assessments.
Wheatley, Christopher J; Beale, Colin M; Bradbury, Richard B; Pearce-Higgins, James W; Critchlow, Rob; Thomas, Chris D
2017-09-01
Climate change vulnerability assessments are commonly used to identify species at risk from global climate change, but the wide range of methodologies available makes it difficult for end users, such as conservation practitioners or policymakers, to decide which method to use as a basis for decision-making. In this study, we evaluate whether different assessments consistently assign species to the same risk categories and whether any of the existing methodologies perform well at identifying climate-threatened species. We compare the outputs of 12 climate change vulnerability assessment methodologies, using both real and simulated species, and validate the methods using historic data for British birds and butterflies (i.e. using historical data to assign risks and more recent data for validation). Our results show that the different vulnerability assessment methods are not consistent with one another; different risk categories are assigned for both the real and simulated sets of species. Validation of the different vulnerability assessments suggests that methods incorporating historic trend data into the assessment perform best at predicting distribution trends in subsequent time periods. This study demonstrates that climate change vulnerability assessments should not be used interchangeably due to the poor overall agreement between methods when considering the same species. The results of our validation provide more support for the use of trend-based rather than purely trait-based approaches, although further validation will be required as data become available. © 2017 The Authors. Global Change Biology Published by John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Meinke, I.
2003-04-01
A new method is presented to validate cloud parametrization schemes in numerical atmospheric models with satellite data of scanning radiometers. This method is applied to the regional atmospheric model HRM (High Resolution Regional Model) using satellite data from ISCCP (International Satellite Cloud Climatology Project). Due to the limited reliability of former validations there has been a need for developing a new validation method: Up to now differences between simulated and measured cloud properties are mostly declared as deficiencies of the cloud parametrization scheme without further investigation. Other uncertainties connected with the model or with the measurements have not been taken into account. Therefore changes in the cloud parametrization scheme based on such kind of validations might not be realistic. The new method estimates uncertainties of the model and the measurements. Criteria for comparisons of simulated and measured data are derived to localize deficiencies in the model. For a better specification of these deficiencies simulated clouds are classified regarding their parametrization. With this classification the localized model deficiencies are allocated to a certain parametrization scheme. Applying this method to the regional model HRM the quality of forecasting cloud properties is estimated in detail. The overestimation of simulated clouds in low emissivity heights especially during the night is localized as model deficiency. This is caused by subscale cloudiness. As the simulation of subscale clouds in the regional model HRM is described by a relative humidity parametrization these deficiencies are connected with this parameterization.
St. Pierre, Tim G.; House, Michael J.; Bangma, Sander J.; Pang, Wenjie; Bathgate, Andrew; Gan, Eng K.; Ayonrinde, Oyekoya T.; Bhathal, Prithi S.; Clouston, Andrew; Olynyk, John K.; Adams, Leon A.
2016-01-01
Background and Aims Validation of non-invasive methods of liver fat quantification requires a reference standard. However, using standard histopathology assessment of liver biopsies is problematical because of poor repeatability. We aimed to assess a stereological method of measuring volumetric liver fat fraction (VLFF) in liver biopsies and to use the method to validate a magnetic resonance imaging method for measurement of VLFF. Methods VLFFs were measured in 59 subjects (1) by three independent analysts using a stereological point counting technique combined with the Delesse principle on liver biopsy histological sections and (2) by three independent analysts using the HepaFat-Scan® technique on magnetic resonance images of the liver. Bland Altman statistics and intraclass correlation (IC) were used to assess the repeatability of each method and the bias between the methods of liver fat fraction measurement. Results Inter-analyst repeatability coefficients for the stereology and HepaFat-Scan® methods were 8.2 (95% CI 7.7–8.8)% and 2.4 (95% CI 2.2–2.5)% VLFF respectively. IC coefficients were 0.86 (95% CI 0.69–0.93) and 0.990 (95% CI 0.985–0.994) respectively. Small biases (≤3.4%) were observable between two pairs of analysts using stereology while no significant biases were observable between any of the three pairs of analysts using HepaFat-Scan®. A bias of 1.4±0.5% VLFF was observed between the HepaFat-Scan® method and the stereological method. Conclusions Repeatability of the stereological method is superior to the previously reported performance of assessment of hepatic steatosis by histopathologists and is a suitable reference standard for validating non-invasive methods of measurement of VLFF. PMID:27501242
A Critical Review of Methods to Evaluate the Impact of FDA Regulatory Actions
Briesacher, Becky A.; Soumerai, Stephen B.; Zhang, Fang; Toh, Sengwee; Andrade, Susan E.; Wagner, Joann L.; Shoaibi, Azadeh; Gurwitz, Jerry H.
2013-01-01
Purpose To conduct a synthesis of the literature on methods to evaluate the impacts of FDA regulatory actions, and identify best practices for future evaluations. Methods We searched MEDLINE for manuscripts published between January 1948 and August 2011 that included terms related to FDA, regulatory actions, and empirical evaluation; the review additionally included FDA-identified literature. We used a modified Delphi method to identify preferred methodologies. We included studies with explicit methods to address threats to validity, and identified designs and analytic methods with strong internal validity that have been applied to other policy evaluations. Results We included 18 studies out of 243 abstracts and papers screened. Overall, analytic rigor in prior evaluations of FDA regulatory actions varied considerably; less than a quarter of studies (22%) included control groups. Only 56% assessed changes in the use of substitute products/services, and 11% examined patient health outcomes. Among studies meeting minimal criteria of rigor, 50% found no impact or weak/modest impacts of FDA actions and 33% detected unintended consequences. Among those studies finding significant intended effects of FDA actions, all cited the importance of intensive communication efforts. There are preferred methods with strong internal validity that have yet to be applied to evaluations of FDA regulatory actions. Conclusions Rigorous evaluations of the impact of FDA regulatory actions have been limited and infrequent. Several methods with strong internal validity are available to improve trustworthiness of future evaluations of FDA policies. PMID:23847020
Hartnell, R E; Stockley, L; Keay, W; Rosec, J-P; Hervio-Heath, D; Van den Berg, H; Leoni, F; Ottaviani, D; Henigman, U; Denayer, S; Serbruyns, B; Georgsson, F; Krumova-Valcheva, G; Gyurova, E; Blanco, C; Copin, S; Strauch, E; Wieczorek, K; Lopatek, M; Britova, A; Hardouin, G; Lombard, B; In't Veld, P; Leclercq, A; Baker-Austin, C
2018-02-10
Globally, vibrios represent an important and well-established group of bacterial foodborne pathogens. The European Commission (EC) mandated the Comite de European Normalisation (CEN) to undertake work to provide validation data for 15 methods in microbiology to support EC legislation. As part of this mandated work programme, merging of ISO/TS 21872-1:2007, which specifies a horizontal method for the detection of V. parahaemolyticus and V. cholerae, and ISO/TS 21872-2:2007, a similar horizontal method for the detection of potentially pathogenic vibrios other than V. cholerae and V. parahaemolyticus was proposed. Both parts of ISO/TS 21872 utilized classical culture-based isolation techniques coupled with biochemical confirmation steps. The work also considered simplification of the biochemical confirmation steps. In addition, because of advances in molecular based methods for identification of human pathogenic Vibrio spp. classical and real-time PCR options were also included within the scope of the validation. These considerations formed the basis of a multi-laboratory validation study with the aim of improving the precision of this ISO technical specification and providing a single ISO standard method to enable detection of these important foodborne Vibrio spp.. To achieve this aim, an international validation study involving 13 laboratories from 9 countries in Europe was conducted in 2013. The results of this validation have enabled integration of the two existing technical specifications targeting the detection of the major foodborne Vibrio spp., simplification of the suite of recommended biochemical identification tests and the introduction of molecular procedures that provide both species level identification and discrimination of putatively pathogenic strains of V. parahaemolyticus by the determination of the presence of theromostable direct and direct related haemolysins. The method performance characteristics generated in this have been included in revised international standard, ISO 21872:2017, published in July 2017. Copyright © 2018. Published by Elsevier B.V.
2015-06-19
effective and scientifically valid method of making comparisons of clothing and equipment changes prior to conducting human research. predictive modeling...valid method of making comparisons of clothing and equipment changes prior to conducting human research. 2 INTRODUCTION Modern day...clothing and equipment changes prior to conducting human research. METHODS Ensembles Three different body armor (BA) plus clothing ensembles were
NASA Astrophysics Data System (ADS)
Wang, Zengwei; Zhu, Ping; Liu, Zhao
2018-01-01
A generalized method for predicting the decoupled transfer functions based on in-situ transfer functions is proposed. The method allows predicting the decoupled transfer functions using coupled transfer functions, without disassembling the system. Two ways to derive relationships between the decoupled and coupled transfer functions are presented. Issues related to immeasurability of coupled transfer functions are also discussed. The proposed method is validated by numerical and experimental case studies.
Construct Validation in Counseling Psychology Research
ERIC Educational Resources Information Center
Hoyt, William T.; Warbasse, Rosalia E.; Chu, Erica Y.
2006-01-01
Counseling psychology researchers devote little attention to theory-based measurement validation, as evidenced by cursory mention of validity issues in the method and discussion sections of published research reports. Especially, many researchers appear unaware of the limitations of correlations between pairs of self-report measures as evidence of…
49 CFR 236.905 - Railroad Safety Program Plan (RSPP).
Code of Federal Regulations, 2012 CFR
2012-10-01
... to be used in the verification and validation process, consistent with appendix C to this part. The...; and (iv) The identification of the safety assessment process. (2) Design for verification and validation. The RSPP must require the identification of verification and validation methods for the...
49 CFR 236.905 - Railroad Safety Program Plan (RSPP).
Code of Federal Regulations, 2014 CFR
2014-10-01
... to be used in the verification and validation process, consistent with appendix C to this part. The...; and (iv) The identification of the safety assessment process. (2) Design for verification and validation. The RSPP must require the identification of verification and validation methods for the...
49 CFR 236.905 - Railroad Safety Program Plan (RSPP).
Code of Federal Regulations, 2013 CFR
2013-10-01
... to be used in the verification and validation process, consistent with appendix C to this part. The...; and (iv) The identification of the safety assessment process. (2) Design for verification and validation. The RSPP must require the identification of verification and validation methods for the...
49 CFR 236.905 - Railroad Safety Program Plan (RSPP).
Code of Federal Regulations, 2011 CFR
2011-10-01
... to be used in the verification and validation process, consistent with appendix C to this part. The...; and (iv) The identification of the safety assessment process. (2) Design for verification and validation. The RSPP must require the identification of verification and validation methods for the...
Heath, A L; Skeaff, C M; Gibson, R S
1999-04-01
The objective of this study was to validate two indirect methods for estimating the extent of menstrual blood loss against a reference method to determine which method would be most appropriate for use in a population of young adult women. Thirty-two women aged 18 to 29 years (mean +/- SD; 22.4 +/- 2.8) were recruited by poster in Dunedin (New Zealand). Data are presented for 29 women. A recall method and a record method for estimating extent of menstrual loss were validated against a weighed reference method. Spearman rank correlation coefficients between blood loss assessed by Weighed Menstrual Loss and Menstrual Record was rs = 0.47 (p = 0.012), and between Weighed Menstrual Loss and Menstrual Recall, was rs = 0.61 (p = 0.001). The Record method correctly classified 66% of participants into the same tertile, grossly misclassifying 14%. The Recall method correctly classified 59% of participants, grossly misclassifying 7%. Reference method menstrual loss calculated for surrogate categories demonstrated a significant difference between the second and third tertiles for the Record method, and between the first and third tertiles for the Recall method. The Menstrual Recall method can differentiate between low and high levels of menstrual blood loss in young adult women, is quick to complete and analyse, and has a low participant burden.
Murphy, Thomas; Schwedock, Julie; Nguyen, Kham; Mills, Anna; Jones, David
2015-01-01
New recommendations for the validation of rapid microbiological methods have been included in the revised Technical Report 33 release from the PDA. The changes include a more comprehensive review of the statistical methods to be used to analyze data obtained during validation. This case study applies those statistical methods to accuracy, precision, ruggedness, and equivalence data obtained using a rapid microbiological methods system being evaluated for water bioburden testing. Results presented demonstrate that the statistical methods described in the PDA Technical Report 33 chapter can all be successfully applied to the rapid microbiological method data sets and gave the same interpretation for equivalence to the standard method. The rapid microbiological method was in general able to pass the requirements of PDA Technical Report 33, though the study shows that there can be occasional outlying results and that caution should be used when applying statistical methods to low average colony-forming unit values. Prior to use in a quality-controlled environment, any new method or technology has to be shown to work as designed by the manufacturer for the purpose required. For new rapid microbiological methods that detect and enumerate contaminating microorganisms, additional recommendations have been provided in the revised PDA Technical Report No. 33. The changes include a more comprehensive review of the statistical methods to be used to analyze data obtained during validation. This paper applies those statistical methods to analyze accuracy, precision, ruggedness, and equivalence data obtained using a rapid microbiological method system being validated for water bioburden testing. The case study demonstrates that the statistical methods described in the PDA Technical Report No. 33 chapter can be successfully applied to rapid microbiological method data sets and give the same comparability results for similarity or difference as the standard method. © PDA, Inc. 2015.
Cresswell, Scott L; Eklund, Robert C
2006-02-01
Athlete burnout research has been hampered by the lack of an adequate measurement tool. The Athlete Burnout Questionnaire (ABQ) and the Maslach Burnout Inventory General Survey (MBI-GS) are two recently developed self-report instruments designed to assess burnout. The convergent and discriminant validity of the ABQ and MBI-GS were assessed through multi-trait/multi-method analysis with a sporting population. Overall, the ABQ and the MBI-GS displayed acceptable convergent validity with matching subscales highly correlated, and satisfactory internal discriminant validity with lower correlations between non-matching subscales. Both scales also indicated an adequate discrimination between the concepts of burnout and depression. These findings add support to previous findings in non-sporting populations that depression and burnout are separate constructs. Based on the psychometric results, construct validity analysis and practical considerations, the results support the use of the ABQ to assess athlete burnout.
NASA Technical Reports Server (NTRS)
Generazio, Edward R. (Inventor)
2012-01-01
A method of validating a probability of detection (POD) testing system using directed design of experiments (DOE) includes recording an input data set of observed hit and miss or analog data for sample components as a function of size of a flaw in the components. The method also includes processing the input data set to generate an output data set having an optimal class width, assigning a case number to the output data set, and generating validation instructions based on the assigned case number. An apparatus includes a host machine for receiving the input data set from the testing system and an algorithm for executing DOE to validate the test system. The algorithm applies DOE to the input data set to determine a data set having an optimal class width, assigns a case number to that data set, and generates validation instructions based on the case number.
Incremental checking of Master Data Management model based on contextual graphs
NASA Astrophysics Data System (ADS)
Lamolle, Myriam; Menet, Ludovic; Le Duc, Chan
2015-10-01
The validation of models is a crucial step in distributed heterogeneous systems. In this paper, an incremental validation method is proposed in the scope of a Model Driven Engineering (MDE) approach, which is used to develop a Master Data Management (MDM) field represented by XML Schema models. The MDE approach presented in this paper is based on the definition of an abstraction layer using UML class diagrams. The validation method aims to minimise the model errors and to optimisethe process of model checking. Therefore, the notion of validation contexts is introduced allowing the verification of data model views. Description logics specify constraints that the models have to check. An experimentation of the approach is presented through an application developed in ArgoUML IDE.
Spectroflurimetric estimation of the new antiviral agent ledipasvir in presence of sofosbuvir
NASA Astrophysics Data System (ADS)
Salama, Fathy M.; Attia, Khalid A.; Abouserie, Ahmed A.; El-Olemy, Ahmed; Abolmagd, Ebrahim
2018-02-01
A spectroflurimetric method has been developed and validated for the selective quantitative determination of ledipasvir in presence of sofosbuvir. In this method the native fluorescence of ledipasvir in ethanol at 405 nm was measured after excitation at 340 nm. The proposed method was validated according to ICH guidelines and show high sensitivity, accuracy and precision. Furthermore this method was successfully applied to the analysis of ledipasvir in pharmaceutical dosage form without interference from sofosbuvir and other additives and the results were statistically compared to a reported method and found no significant difference.
External Standards or Standard Addition? Selecting and Validating a Method of Standardization
NASA Astrophysics Data System (ADS)
Harvey, David T.
2002-05-01
A common feature of many problem-based laboratories in analytical chemistry is a lengthy independent project involving the analysis of "real-world" samples. Students research the literature, adapting and developing a method suitable for their analyte, sample matrix, and problem scenario. Because these projects encompass the complete analytical process, students must consider issues such as obtaining a representative sample, selecting a method of analysis, developing a suitable standardization, validating results, and implementing appropriate quality assessment/quality control practices. Most textbooks and monographs suitable for an undergraduate course in analytical chemistry, however, provide only limited coverage of these important topics. The need for short laboratory experiments emphasizing important facets of method development, such as selecting a method of standardization, is evident. The experiment reported here, which is suitable for an introductory course in analytical chemistry, illustrates the importance of matrix effects when selecting a method of standardization. Students also learn how a spike recovery is used to validate an analytical method, and obtain a practical experience in the difference between performing an external standardization and a standard addition.
Sakai, Shinobu; Adachi, Reiko; Akiyama, Hiroshi; Teshima, Reiko
2013-06-19
A labeling system for food allergenic ingredients was established in Japan in April 2002. To monitor the labeling, the Japanese government announced official methods for detecting allergens in processed foods in November 2002. The official methods consist of quantitative screening tests using enzyme-linked immunosorbent assays (ELISAs) and qualitative confirmation tests using Western blotting or polymerase chain reactions (PCR). In addition, the Japanese government designated 10 μg protein/g food (the corresponding allergenic ingredient soluble protein weight/food weight), determined by ELISA, as the labeling threshold. To standardize the official methods, the criteria for the validation protocol were described in the official guidelines. This paper, which was presented at the Advances in Food Allergen Detection Symposium, ACS National Meeting and Expo, San Diego, CA, Spring 2012, describes the validation protocol outlined in the official Japanese guidelines, the results of interlaboratory studies for the quantitative detection method (ELISA for crustacean proteins) and the qualitative detection method (PCR for shrimp and crab DNAs), and the reliability of the detection methods.
Kumar, Puspendra; Jha, Shivesh; Naved, Tanveer
2013-01-01
Validated modified lycopodium spore method has been developed for simple and rapid quantification of herbal powdered drugs. Lycopodium spore method was performed on ingredients of Shatavaryadi churna, an ayurvedic formulation used as immunomodulator, galactagogue, aphrodisiac and rejuvenator. Estimation of diagnostic characters of each ingredient of Shatavaryadi churna individually was carried out. Microscopic determination, counting of identifying number, measurement of area, length and breadth of identifying characters were performed using Leica DMLS-2 microscope. The method was validated for intraday precision, linearity, specificity, repeatability, accuracy and system suitability, respectively. The method is simple, precise, sensitive, and accurate, and can be used for routine standardisation of raw materials of herbal drugs. This method gives the ratio of individual ingredients in the powdered drug so that any adulteration of genuine drug with its adulterant can be found out. The method shows very good linearity value between 0.988-0.999 for number of identifying character and area of identifying character. Percentage purity of the sample drug can be determined by using the linear equation of standard genuine drug.
Macedo, Fabio; Marsico, Eliane Teixeira; Conte-Júnior, Carlos Adam; de Resende, Michele Fabri; Brasil, Taila Figueiredo; Pereira Netto, Annibal Duarte
2015-07-15
An analytical method was developed and validated for the simultaneous determination of four macrocyclic lactones (ML) (abamectin, doramectin, ivermectin and moxidectin) in butter, using liquid chromatography with fluorescence detection. The method employed heated liquid-liquid extraction and a mixture of acetonitrile, ethyl acetate and water, with preconcentration and derivatization, to produce stable fluorescent derivatives. The chromatographic run time was <12.5 min, with excellent separation. The method validation followed international guidelines and employed fortified butter samples. The figures of merit obtained, e.g. recovery (72.4-106.5%), repeatability (8.8%), within-laboratory reproducibility (15.7%) and limits of quantification (0.09-0.16 μg kg(-1)) were satisfactory for the desired application. The application of the method to real samples showed that ML residues were present in six of the ten samples evaluated. The method proved to be simple, easy and appropriate for simultaneous determination of ML residues in butter. To our knowledge, this is the first method described for the evaluation of ML in butter. Copyright © 2015. Published by Elsevier Ltd.
Gupta, Abhishek; Singh, Yogendra; Srinivas, Kona S.; Jain, Garima; Sreekumar, V. B.; Semwal, Vinod Prasad
2010-01-01
Objective: Arterolane maleate is an antimalarial drug currently under Phase III clinical evaluation, and presents a simple, economical and scalable synthesis, and does not suffer from safety problems. Arterolane maleate is more active than artemisinin; and is cheap to produce. It has a longer lifetime in the plasma, so it stays active longer in the body. To provide quality control over the manufacture of any API, it is essential to develop highly selective analytical methods. In the current article we are reporting the development and validation of a rapid and specific Head space gas chromatographic (HSGC) method for the determination of organic volatile impurities (residual solvents) in Arterolane Maleate bulk drug. Materials and Methods: The method development and its validation were performed on Perkin Elmer's gas chromatographic system equipped with Flame Ionization detector and head space analyzer. The method involved a thermal gradient elution of ten residual solvents present in arterolane maleate salt in RTx-624, 30 m × 0.32 mm, 1.8 μ column using nitrogen gas as a carrier. The flow rate was 0.5 ml/min and flame ionization detector (FID) was used. Results: During method validation, parameters such as precision, linearity, accuracy, limit of quantification and detection and specificity were evaluated, which remained within acceptable limits. Conclusions: The method has been successfully applied for the quantification of the amount of residual solvents present in arterolane maleate bulk drug.The method presents a simple and reliable solution for the routine quantitative analysis of residual solvents in Arterolane maleate bulk drug. PMID:21814428
Grelewska-Nowotko, Katarzyna; Żurawska-Zajfert, Magdalena; Żmijewska, Ewelina; Sowa, Sławomir
2018-05-01
In recent years, digital polymerase chain reaction (dPCR), a new molecular biology technique, has been gaining in popularity. Among many other applications, this technique can also be used for the detection and quantification of genetically modified organisms (GMOs) in food and feed. It might replace the currently widely used real-time PCR method (qPCR), by overcoming problems related to the PCR inhibition and the requirement of certified reference materials to be used as a calibrant. In theory, validated qPCR methods can be easily transferred to the dPCR platform. However, optimization of the PCR conditions might be necessary. In this study, we report the transfer of two validated qPCR methods for quantification of maize DAS1507 and NK603 events to the droplet dPCR (ddPCR) platform. After some optimization, both methods have been verified according to the guidance of the European Network of GMO Laboratories (ENGL) on analytical method verification (ENGL working group on "Method Verification." (2011) Verification of Analytical Methods for GMO Testing When Implementing Interlaboratory Validated Methods). Digital PCR methods performed equally or better than the qPCR methods. Optimized ddPCR methods confirm their suitability for GMO determination in food and feed.
Azevedo de Brito, Wanessa; Gomes Dantas, Monique; Andrade Nogueira, Fernando Henrique; Ferreira da Silva-Júnior, Edeildo; Xavier de Araújo-Júnior, João; Aquino, Thiago Mendonça de; Adélia Nogueira Ribeiro, Êurica; da Silva Solon, Lilian Grace; Soares Aragão, Cícero Flávio; Barreto Gomes, Ana Paula
2017-08-30
Guanylhydrazones are molecules with great pharmacological potential in various therapeutic areas, including antitumoral activity. Factorial design is an excellent tool in the optimization of a chromatographic method, because it is possible quickly change factors such as temperature, mobile phase composition, mobile phase pH, column length, among others to establish the optimal conditions of analysis. The aim of the present work was to develop and validate a HPLC and UHPLC methods for the simultaneous determination of guanylhydrazones with anticancer activity employing experimental design. Precise, exact, linear and robust HPLC and UHPLC methods were developed and validated for the simultaneous quantification of the guanylhydrazones LQM10, LQM14, and LQM17. The UHPLC method was more economic, with a four times less solvent consumption, and 20 times less injection volume, what allowed better column performance. Comparing the empirical approach employed in the HPLC method development to the DoE approach employed in the UHPLC method development, we can conclude that the factorial design made the method development faster, more practical and rational. This resulted in methods that can be employed in the analysis, evaluation and quality control of these new synthetic guanylhydrazones.
Hanskamp-Sebregts, Mirelle; Zegers, Marieke; Vincent, Charles; van Gurp, Petra J; de Vet, Henrica C W; Wollersheim, Hub
2016-01-01
Objectives Record review is the most used method to quantify patient safety. We systematically reviewed the reliability and validity of adverse event detection with record review. Design A systematic review of the literature. Methods We searched PubMed, EMBASE, CINAHL, PsycINFO and the Cochrane Library and from their inception through February 2015. We included all studies that aimed to describe the reliability and/or validity of record review. Two reviewers conducted data extraction. We pooled κ values (κ) and analysed the differences in subgroups according to number of reviewers, reviewer experience and training level, adjusted for the prevalence of adverse events. Results In 25 studies, the psychometric data of the Global Trigger Tool (GTT) and the Harvard Medical Practice Study (HMPS) were reported and 24 studies were included for statistical pooling. The inter-rater reliability of the GTT and HMPS showed a pooled κ of 0.65 and 0.55, respectively. The inter-rater agreement was statistically significantly higher when the group of reviewers within a study consisted of a maximum five reviewers. We found no studies reporting on the validity of the GTT and HMPS. Conclusions The reliability of record review is moderate to substantial and improved when a small group of reviewers carried out record review. The validity of the record review method has never been evaluated, while clinical data registries, autopsy or direct observations of patient care are potential reference methods that can be used to test concurrent validity. PMID:27550650
Social Validity: Perceptions of Check and Connect with Early Literacy Support
ERIC Educational Resources Information Center
Miltich Lyst, Aimee; Gabriel, Stacey; O'Shaughnessy, Tam E.; Meyers, Joel; Meyers, Barbara
2005-01-01
This article underscores the potential advantages of qualitative methods to illustrate the depth and complexity of social validity. This investigation evaluates the social validity of Check and Connect with Early Literacy Support (CCEL), through the perspectives of teachers and caregivers whose children participated in the intervention. Teachers…
Remote Patron Validation: Posting a Proxy Server at the Digital Doorway.
ERIC Educational Resources Information Center
Webster, Peter
2002-01-01
Discussion of remote access to library services focuses on proxy servers as a method for remote access, based on experiences at Saint Mary's University (Halifax). Topics include Internet protocol user validation; browser-directed proxies; server software proxies; vendor alternatives for validating remote users; and Internet security issues. (LRW)
Evaluation of Measurement Instrument Criterion Validity in Finite Mixture Settings
ERIC Educational Resources Information Center
Raykov, Tenko; Marcoulides, George A.; Li, Tenglong
2016-01-01
A method for evaluating the validity of multicomponent measurement instruments in heterogeneous populations is discussed. The procedure can be used for point and interval estimation of criterion validity of linear composites in populations representing mixtures of an unknown number of latent classes. The approach permits also the evaluation of…
Adolescent Personality: A Five-Factor Model Construct Validation
ERIC Educational Resources Information Center
Baker, Spencer T.; Victor, James B.; Chambers, Anthony L.; Halverson, Jr., Charles F.
2004-01-01
The purpose of this study was to investigate convergent and discriminant validity of the five-factor model of adolescent personality in a school setting using three different raters (methods): self-ratings, peer ratings, and teacher ratings. The authors investigated validity through a multitrait-multimethod matrix and a confirmatory factor…
49 CFR 236.905 - Railroad Safety Program Plan (RSPP).
Code of Federal Regulations, 2010 CFR
2010-10-01
... validation. The RSPP must require the identification of verification and validation methods for the... to be used in the verification and validation process, consistent with appendix C to this part. The... information. (3) If no action is taken on the petition within 180 days, the petition remains pending for...
DOT National Transportation Integrated Search
1979-03-01
There are several conditions that can influence the calculation of the statistical validity of a test battery such as that used to selected Air Traffic Control Specialists. Two conditions of prime importance to statistical validity are recruitment pr...
Evaluation of Validity and Reliability for Hierarchical Scales Using Latent Variable Modeling
ERIC Educational Resources Information Center
Raykov, Tenko; Marcoulides, George A.
2012-01-01
A latent variable modeling method is outlined, which accomplishes estimation of criterion validity and reliability for a multicomponent measuring instrument with hierarchical structure. The approach provides point and interval estimates for the scale criterion validity and reliability coefficients, and can also be used for testing composite or…
Designing the Nuclear Energy Attitude Scale.
ERIC Educational Resources Information Center
Calhoun, Lawrence; And Others
1988-01-01
Presents a refined method for designing a valid and reliable Likert-type scale to test attitudes toward the generation of electricity from nuclear energy. Discusses various tests of validity that were used on the nuclear energy scale. Reports results of administration and concludes that the test is both reliable and valid. (CW)
Initial Validation of the Mental Health Provider Stigma Inventory
ERIC Educational Resources Information Center
Kennedy, Stephanie C.; Abell, Neil; Mennicke, Annelise
2017-01-01
Objective: To conduct an initial validation of the mental health provider stigma inventory (MHPSI). The MHPSI assesses stigma within the service provider--client relationship on three domains--namely, attitudes, behaviors, and coworker influence. Methods: Initial validation of the MHPSI was conducted with a sample of 212 mental health employees…
A Delphi Study and Initial Validation of Counselor Supervision Competencies
ERIC Educational Resources Information Center
Neuer Colburn, Anita A.; Grothaus, Tim; Hays, Danica G.; Milliken, Tammi
2016-01-01
The authors addressed the lack of supervision training standards for doctoral counseling graduates by developing and validating an initial list of supervision competencies. They used content analysis, Delphi polling, and content validity methods to generate a list, vetted by 2 different panels of supervision experts, of 33 competencies grouped…
USDA-ARS?s Scientific Manuscript database
In this study, optimization, extension, and validation of a streamlined, qualitative and quantitative multiclass, multiresidue method was conducted to monitor great than100 veterinary drug residues in meat using ultrahigh-performance liquid chromatography – tandem mass spectrometry (UHPLC-MS/MS). I...
Alternative method to validate the seasonal land cover regions of the conterminous United States
Zhiliang Zhu; Donald O. Ohlen; Raymond L. Czaplewski; Robert E. Burgan
1996-01-01
An accuracy assessment method involving double sampling and the multivariate composite estimator has been used to validate the prototype seasonal land cover characteristics database of the conterminous United States. The database consists of 159 land cover classes, classified using time series of 1990 1-km satellite data and augmented with ancillary data including...
ERIC Educational Resources Information Center
Skelton, Alexander; Riley, David; Wales, David; Vess, James
2006-01-01
A growing research base supports the predictive validity of actuarial methods of risk assessment with sexual offenders. These methods use clearly defined variables with demonstrated empirical association with re-offending. The advantages of actuarial measures for screening large numbers of offenders quickly and economically are further enhanced…
Validity of a Simulation Game as a Method for History Teaching
ERIC Educational Resources Information Center
Corbeil, Pierre; Laveault, Dany
2011-01-01
The aim of this research is, first, to determine the validity of a simulation game as a method of teaching and an instrument for the development of reasoning and, second, to study the relationship between learning and students' behavior toward games. The participants were college students in a History of International Relations course, with two…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Choi, Yong Joon; Yoo, Jun Soo; Smith, Curtis Lee
2015-09-01
This INL plan comprehensively describes the Requirements Traceability Matrix (RTM) on main physics and numerical method of the RELAP-7. The plan also describes the testing-based software verification and validation (SV&V) process—a set of specially designed software models used to test RELAP-7.
This product is an LC/MS/MS single laboratory validated method for the determination of cylindrospermopsin and anatoxin-a in ambient waters. The product contains step-by-step instructions for sample preparation, analyses, preservation, sample holding time and QC protocols to ensu...
ERIC Educational Resources Information Center
Kimball, Steven M.; Milanowski, Anthony
2009-01-01
Purpose: The article reports on a study of school leader decision making that examined variation in the validity of teacher evaluation ratings in a school district that has implemented a standards-based teacher evaluation system. Research Methods: Applying mixed methods, the study used teacher evaluation ratings and value-added student achievement…
Stern, K I; Malkova, T L
The objective of the present study was the development and validation of sibutramine demethylated derivatives, desmethyl sibutramine and didesmethyl sibutramine. Gas-liquid chromatography with the flame ionization detector was used for the quantitative determination of the above substances in dietary supplements. The conditions for the chromatographic determination of the analytes in the presence of the reference standard, methyl stearate, were proposed allowing to achieve the efficient separation. The method has the necessary sensitivity, specificity, linearity, accuracy, and precision (on the intra-day and inter-day basis) which suggests its good validation characteristics. The proposed method can be employed in the analytical laboratories for the quantitative determination of sibutramine derivatives in biologically active dietary supplements.
[Validation Study for Analytical Method of Diarrhetic Shellfish Poisons in 9 Kinds of Shellfish].
Yamaguchi, Mizuka; Yamaguchi, Takahiro; Kakimoto, Kensaku; Nagayoshi, Haruna; Okihashi, Masahiro; Kajimura, Keiji
2016-01-01
A method was developed for the simultaneous determination of okadaic acid, dinophysistoxin-1 and dinophysistoxin-2 in shellfish using ultra performance liquid chromatography with tandem mass spectrometry. Shellfish poisons in spiked samples were extracted with methanol and 90% methanol, and were hydrolyzed with 2.5 mol/L sodium hydroxide solution. Purification was done on an HLB solid-phase extraction column. This method was validated in accordance with the notification of Ministry of Health, Labour and Welfare of Japan. As a result of the validation study in nine kinds of shellfish, the trueness, repeatability and within-laboratory reproducibility were 79-101%, less than 12 and 16%, respectively. The trueness and precision met the target values of notification.
Improvement of Simulation Method in Validation of Software of the Coordinate Measuring Systems
NASA Astrophysics Data System (ADS)
Nieciąg, Halina
2015-10-01
Software is used in order to accomplish various tasks at each stage of the functioning of modern measuring systems. Before metrological confirmation of measuring equipment, the system has to be validated. This paper discusses the method for conducting validation studies of a fragment of software to calculate the values of measurands. Due to the number and nature of the variables affecting the coordinate measurement results and the complex character and multi-dimensionality of measurands, the study used the Monte Carlo method of numerical simulation. The article presents an attempt of possible improvement of results obtained by classic Monte Carlo tools. The algorithm LHS (Latin Hypercube Sampling) was implemented as alternative to the simple sampling schema of classic algorithm.
Alternative methods to evaluate trial level surrogacy.
Abrahantes, Josè Cortiñas; Shkedy, Ziv; Molenberghs, Geert
2008-01-01
The evaluation and validation of surrogate endpoints have been extensively studied in the last decade. Prentice [1] and Freedman, Graubard and Schatzkin [2] laid the foundations for the evaluation of surrogate endpoints in randomized clinical trials. Later, Buyse et al. [5] proposed a meta-analytic methodology, producing different methods for different settings, which was further studied by Alonso and Molenberghs [9], in their unifying approach based on information theory. In this article, we focus our attention on the trial-level surrogacy and propose alternative procedures to evaluate such surrogacy measure, which do not pre-specify the type of association. A promising correction based on cross-validation is investigated. As well as the construction of confidence intervals for this measure. In order to avoid making assumption about the type of relationship between the treatment effects and its distribution, a collection of alternative methods, based on regression trees, bagging, random forests, and support vector machines, combined with bootstrap-based confidence interval and, should one wish, in conjunction with a cross-validation based correction, will be proposed and applied. We apply the various strategies to data from three clinical studies: in opthalmology, in advanced colorectal cancer, and in schizophrenia. The results obtained for the three case studies are compared; they indicate that using random forest or bagging models produces larger estimated values for the surrogacy measure, which are in general stabler and the confidence interval narrower than linear regression and support vector regression. For the advanced colorectal cancer studies, we even found the trial-level surrogacy is considerably different from what has been reported. In general the alternative methods are more computationally demanding, and specially the calculation of the confidence intervals, require more computational time that the delta-method counterpart. First, more flexible modeling techniques can be used, allowing for other type of association. Second, when no cross-validation-based correction is applied, overly optimistic trial-level surrogacy estimates will be found, thus cross-validation is highly recommendable. Third, the use of the delta method to calculate confidence intervals is not recommendable since it makes assumptions valid only in very large samples. It may also produce range-violating limits. We therefore recommend alternatives: bootstrap methods in general. Also, the information-theoretic approach produces comparable results with the bagging and random forest approaches, when cross-validation correction is applied. It is also important to observe that, even for the case in which the linear model might be a good option too, bagging methods perform well too, and their confidence intervals were more narrow.
MRPrimer: a MapReduce-based method for the thorough design of valid and ranked primers for PCR.
Kim, Hyerin; Kang, NaNa; Chon, Kang-Wook; Kim, Seonho; Lee, NaHye; Koo, JaeHyung; Kim, Min-Soo
2015-11-16
Primer design is a fundamental technique that is widely used for polymerase chain reaction (PCR). Although many methods have been proposed for primer design, they require a great deal of manual effort to generate feasible and valid primers, including homology tests on off-target sequences using BLAST-like tools. That approach is inconvenient for many target sequences of quantitative PCR (qPCR) due to considering the same stringent and allele-invariant constraints. To address this issue, we propose an entirely new method called MRPrimer that can design all feasible and valid primer pairs existing in a DNA database at once, while simultaneously checking a multitude of filtering constraints and validating primer specificity. Furthermore, MRPrimer suggests the best primer pair for each target sequence, based on a ranking method. Through qPCR analysis using 343 primer pairs and the corresponding sequencing and comparative analyses, we showed that the primer pairs designed by MRPrimer are very stable and effective for qPCR. In addition, MRPrimer is computationally efficient and scalable and therefore useful for quickly constructing an entire collection of feasible and valid primers for frequently updated databases like RefSeq. Furthermore, we suggest that MRPrimer can be utilized conveniently for experiments requiring primer design, especially real-time qPCR. © The Author(s) 2015. Published by Oxford University Press on behalf of Nucleic Acids Research.
Cumulative query method for influenza surveillance using search engine data.
Seo, Dong-Woo; Jo, Min-Woo; Sohn, Chang Hwan; Shin, Soo-Yong; Lee, JaeHo; Yu, Maengsoo; Kim, Won Young; Lim, Kyoung Soo; Lee, Sang-Il
2014-12-16
Internet search queries have become an important data source in syndromic surveillance system. However, there is currently no syndromic surveillance system using Internet search query data in South Korea. The objective of this study was to examine correlations between our cumulative query method and national influenza surveillance data. Our study was based on the local search engine, Daum (approximately 25% market share), and influenza-like illness (ILI) data from the Korea Centers for Disease Control and Prevention. A quota sampling survey was conducted with 200 participants to obtain popular queries. We divided the study period into two sets: Set 1 (the 2009/10 epidemiological year for development set 1 and 2010/11 for validation set 1) and Set 2 (2010/11 for development Set 2 and 2011/12 for validation Set 2). Pearson's correlation coefficients were calculated between the Daum data and the ILI data for the development set. We selected the combined queries for which the correlation coefficients were .7 or higher and listed them in descending order. Then, we created a cumulative query method n representing the number of cumulative combined queries in descending order of the correlation coefficient. In validation set 1, 13 cumulative query methods were applied, and 8 had higher correlation coefficients (min=.916, max=.943) than that of the highest single combined query. Further, 11 of 13 cumulative query methods had an r value of ≥.7, but 4 of 13 combined queries had an r value of ≥.7. In validation set 2, 8 of 15 cumulative query methods showed higher correlation coefficients (min=.975, max=.987) than that of the highest single combined query. All 15 cumulative query methods had an r value of ≥.7, but 6 of 15 combined queries had an r value of ≥.7. Cumulative query method showed relatively higher correlation with national influenza surveillance data than combined queries in the development and validation set.
A Bayesian Approach to Determination of F, D, and Z Values Used in Steam Sterilization Validation.
Faya, Paul; Stamey, James D; Seaman, John W
2017-01-01
For manufacturers of sterile drug products, steam sterilization is a common method used to provide assurance of the sterility of manufacturing equipment and products. The validation of sterilization processes is a regulatory requirement and relies upon the estimation of key resistance parameters of microorganisms. Traditional methods have relied upon point estimates for the resistance parameters. In this paper, we propose a Bayesian method for estimation of the well-known D T , z , and F o values that are used in the development and validation of sterilization processes. A Bayesian approach allows the uncertainty about these values to be modeled using probability distributions, thereby providing a fully risk-based approach to measures of sterility assurance. An example is given using the survivor curve and fraction negative methods for estimation of resistance parameters, and we present a means by which a probabilistic conclusion can be made regarding the ability of a process to achieve a specified sterility criterion. LAY ABSTRACT: For manufacturers of sterile drug products, steam sterilization is a common method used to provide assurance of the sterility of manufacturing equipment and products. The validation of sterilization processes is a regulatory requirement and relies upon the estimation of key resistance parameters of microorganisms. Traditional methods have relied upon point estimates for the resistance parameters. In this paper, we propose a Bayesian method for estimation of the critical process parameters that are evaluated in the development and validation of sterilization processes. A Bayesian approach allows the uncertainty about these parameters to be modeled using probability distributions, thereby providing a fully risk-based approach to measures of sterility assurance. An example is given using the survivor curve and fraction negative methods for estimation of resistance parameters, and we present a means by which a probabilistic conclusion can be made regarding the ability of a process to achieve a specified sterility criterion. © PDA, Inc. 2017.
Validity of Bioelectrical Impedance Analysis to Estimation Fat-Free Mass in the Army Cadets.
Langer, Raquel D; Borges, Juliano H; Pascoa, Mauro A; Cirolini, Vagner X; Guerra-Júnior, Gil; Gonçalves, Ezequiel M
2016-03-11
Bioelectrical Impedance Analysis (BIA) is a fast, practical, non-invasive, and frequently used method for fat-free mass (FFM) estimation. The aims of this study were to validate predictive equations of BIA to FFM estimation in Army cadets and to develop and validate a specific BIA equation for this population. A total of 396 males, Brazilian Army cadets, aged 17-24 years were included. The study used eight published predictive BIA equations, a specific equation in FFM estimation, and dual-energy X-ray absorptiometry (DXA) as a reference method. Student's t-test (for paired sample), linear regression analysis, and Bland-Altman method were used to test the validity of the BIA equations. Predictive BIA equations showed significant differences in FFM compared to DXA (p < 0.05) and large limits of agreement by Bland-Altman. Predictive BIA equations explained 68% to 88% of FFM variance. Specific BIA equations showed no significant differences in FFM, compared to DXA values. Published BIA predictive equations showed poor accuracy in this sample. The specific BIA equations, developed in this study, demonstrated validity for this sample, although should be used with caution in samples with a large range of FFM.
Joo, Hyun-Woo; Lee, Chang-Hwan; Rho, Jong-Seok; Jung, Hyun-Kyo
2003-08-01
In this paper, an inversion scheme for piezoelectric constants of piezoelectric transformers is proposed. The impedance of piezoelectric transducers is calculated using a three-dimensional finite element method. The validity of this is confirmed experimentally. The effects of material coefficients on piezoelectric transformers are investigated numerically. Six material coefficient variables for piezoelectric transformers were selected, and a design sensitivity method was adopted as an inversion scheme. The validity of the proposed method was confirmed by step-up ratio calculations. The proposed method is applied to the analysis of a sample piezoelectric transformer, and its resonance characteristics are obtained by numerically combined equivalent circuit method.
Yuan, XiaoDong; Tang, Wei; Shi, WenWei; Yu, Libao; Zhang, Jing; Yuan, Qing; You, Shan; Wu, Ning; Ao, Guokun; Ma, Tingting
2018-07-01
To develop a convenient and rapid single-kidney CT-GFR technique. One hundred and twelve patients referred for multiphasic renal CT and 99mTc-DTPA renal dynamic imaging Gates-GFR measurement were prospectively included and randomly divided into two groups of 56 patients each: the training group and the validation group. On the basis of the nephrographic phase images, the fractional renal accumulation (FRA) was calculated and correlated with the Gates-GFR in the training group. From this correlation a formula was derived for single-kidney CT-GFR calculation, which was validated by a paired t test and linear regression analysis with the single-kidney Gates-GFR in the validation group. In the training group, the FRA (x-axis) correlated well (r = 0.95, p < 0.001) with single-kidney Gates-GFR (y-axis), producing a regression equation of y = 1665x + 1.5 for single-kidney CT-GFR calculation. In the validation group, the difference between the methods of single-kidney GFR measurements was 0.38 ± 5.57 mL/min (p = 0.471); the regression line is identical to the diagonal (intercept = 0 and slope = 1) (p = 0.727 and p = 0.473, respectively), with a standard deviation of residuals of 5.56 mL/min. A convenient and rapid single-kidney CT-GFR technique was presented and validated in this investigation. • The new CT-GFR method takes about 2.5 min of patient time. • The CT-GFR method demonstrated identical results to the Gates-GFR method. • The CT-GFR method is based on the fractional renal accumulation of iodinated CM. • The CT-GFR method is achieved without additional radiation dose to the patient.
Iordanova, B.; Rosenbaum, D.; Norman, D.; Weiner, M.; Studholme, C.
2007-01-01
BACKGROUND AND PURPOSE Brain volumetry is widely used for evaluating tissue degeneration; however, the parcellation methods are rarely validated and use arbitrary planes to mark boundaries of brain regions. The goal of this study was to develop, validate, and apply an MR imaging tracing method for the parcellation of 3 major gyri of the frontal lobe, which uses only local landmarks intrinsic to the structures of interest, without the need for global reorientation or the use of dividing planes or lines. METHODS Studies were performed on 25 subjects—healthy controls and subjects diagnosed with Lewy body dementia and Alzheimer disease—with significant variation in the underlying gyral anatomy and state of atrophy. The protocol was evaluated by using multiple observers tracing scans of subjects diagnosed with neurodegenerative disease and those aging normally, and the results were compared by spatial overlap agreement. To confirm the results, observers marked the same locations in different brains. We illustrated the variabilities of the key boundaries that pose the greatest challenge to defining consistent parcellations across subjects. RESULTS The resulting gyral volumes were evaluated, and their consistency across raters was used as an additional assessment of the validity of our marking method. The agreement on a scale of 0–1 was found to be 0.83 spatial and 0.90 volumetric for the same rater and 0.85 spatial and 0.90 volumetric for 2 different raters. The results revealed that the protocol remained consistent across different neurodegenerative conditions. CONCLUSION Our method provides a simple and reliable way for the volumetric evaluation of frontal lobe neurodegeneration and can be used as a resource for larger comparative studies as well as a validation procedure of automated algorithms. PMID:16971629
Trijsburg, Laura; de Vries, Jeanne Hm; Hollman, Peter Ch; Hulshof, Paul Jm; van 't Veer, Pieter; Boshuizen, Hendriek C; Geelen, Anouk
2018-05-08
To compare the performance of the commonly used 24 h recall (24hR) with the more distinct duplicate portion (DP) as reference method for validation of fatty acid intake estimated with an FFQ. Intakes of SFA, MUFA, n-3 fatty acids and linoleic acid (LA) were estimated by chemical analysis of two DP and by on average five 24hR and two FFQ. Plasma n-3 fatty acids and LA were used to objectively compare ranking of individuals based on DP and 24hR. Multivariate measurement error models were used to estimate validity coefficients and attenuation factors for the FFQ with the DP and 24hR as reference methods. Wageningen, the Netherlands. Ninety-two men and 106 women (aged 20-70 years). Validity coefficients for the fatty acid estimates by the FFQ tended to be lower when using the DP as reference method compared with the 24hR. Attenuation factors for the FFQ tended to be slightly higher based on the DP than those based on the 24hR as reference method. Furthermore, when using plasma fatty acids as reference, the DP showed comparable to slightly better ranking of participants according to their intake of n-3 fatty acids (0·33) and n-3:LA (0·34) than the 24hR (0·22 and 0·24, respectively). The 24hR gives only slightly different results compared with the distinctive but less feasible DP, therefore use of the 24hR seems appropriate as the reference method for FFQ validation of fatty acid intake.
Mishra, Shikha; Aeri, Vidhu
2017-12-01
Saraca asoca Linn. (Caesalpiniaceae) is an important traditional remedy for gynaecological disorders and it contains lyoniside, an aryl tetralin lignan glycoside. The aglycone of lyoniside, lyoniresinol possesses structural similarity to enterolignan precursors which are established phytoestrogens. This work illustrates biotransformation of lyoniside to lyoniresinol using Woodfordia fruticosa Kurz. (Lythraceae) flowers and simultaneous quantification of lyoniside and lyoniresinol using a validated HPTLC method. The aqueous extract prepared from S. asoca bark was fermented using W. fruticosa flowers. The substrate and fermented product both were simultaneously analyzed using solvent system:toluene:ethyl acetate:formic acid (4:3:0.4) at 254 nm. The method was validated for specificity, accuracy, precision, linearity, sensitivity and robustness as per ICH guidelines. The substrate showed the presence of lyoniside, however, it decreased as the fermentation proceeded. On 3rd day, lyoniresinol starts appearing in the medium. In 8 days duration most of the lyoniside converted to lyoniresinol. The developed method was specific for lyoniside and lyoniresinol. Lyoniside and lyoniresinol showed linearity in the range of 250-3000 and 500-2500 ng. The method was accurate as resulted in 99.84% and 99.83% recovery, respectively, for lyoniside and lyoniresinol. Aryl tetralin lignan glycoside, lyoniside was successfully transformed into lyoniresinol using W. fruticosa flowers and their contents were simultaneously analyzed using developed validated HPTLC method.
NASA Astrophysics Data System (ADS)
Rohyami, Yuli; Pribadi, Rizki Maulana
2017-12-01
Formalin is a food preservative that is prohibited by the government, but the abuse of these chemicals is still widely found. The presence of formalin can be detected by using a typical reagent that can ensure the presence of formaldehyde qualitatively and quantitatively. This research was conducted to validate the method of determining formalin in tofu by using Nash reagent in UV-Vis spectrophotometry. The addition of Nash reagent will lead to the formation of diacetyldihydrolutidin complex. The study was performed by stability test of deacetyldihydrolutidine complex against time and pH. Validation of methods for formalin testing in tofu with diacetyldihydrolutidine by UV-Vis spectrophotometry. The results showed that 3,5-diacetyl-dihydrolutidine complex is stable at pH of 7 and stable in the range of 70-120 minutes. The validation shows that the method gives good precision and accuracy of 83.78%. The method has the limit of detection of 1.3681 µg/mL, limit of quantification of 4,5603 µg/mL, and the estimated uncertainty of measurement of 1.30 µg/mL. The test showed that the tofu contained formalin 3.09 ± 1.30 µg/mL. These values provide information that this method can be used as a procedure for the determination of formalin on tofu.
A novel validation and calibration method for motion capture systems based on micro-triangulation.
Nagymáté, Gergely; Tuchband, Tamás; Kiss, Rita M
2018-06-06
Motion capture systems are widely used to measure human kinematics. Nevertheless, users must consider system errors when evaluating their results. Most validation techniques for these systems are based on relative distance and displacement measurements. In contrast, our study aimed to analyse the absolute volume accuracy of optical motion capture systems by means of engineering surveying reference measurement of the marker coordinates (uncertainty: 0.75 mm). The method is exemplified on an 18 camera OptiTrack Flex13 motion capture system. The absolute accuracy was defined by the root mean square error (RMSE) between the coordinates measured by the camera system and by engineering surveying (micro-triangulation). The original RMSE of 1.82 mm due to scaling error was managed to be reduced to 0.77 mm while the correlation of errors to their distance from the origin reduced from 0.855 to 0.209. A simply feasible but less accurate absolute accuracy compensation method using tape measure on large distances was also tested, which resulted in similar scaling compensation compared to the surveying method or direct wand size compensation by a high precision 3D scanner. The presented validation methods can be less precise in some respects as compared to previous techniques, but they address an error type, which has not been and cannot be studied with the previous validation methods. Copyright © 2018 Elsevier Ltd. All rights reserved.
Development and Testing of a Method for Validating Chemical Inactivation of Ebola Virus.
Alfson, Kendra J; Griffiths, Anthony
2018-03-13
Complete inactivation of infectious Ebola virus (EBOV) is required before a sample may be removed from a Biosafety Level 4 laboratory. The United States Federal Select Agent Program regulations require that procedures used to demonstrate chemical inactivation must be validated in-house to confirm complete inactivation. The objective of this study was to develop a method for validating chemical inactivation of EBOV and then demonstrate the effectiveness of several commonly-used inactivation methods. Samples containing infectious EBOV ( Zaire ebolavirus ) in different matrices were treated, and the sample was diluted to limit the cytopathic effect of the inactivant. The presence of infectious virus was determined by assessing the cytopathic effect in Vero E6 cells. Crucially, this method did not result in a loss of infectivity in control samples, and we were able to detect less than five infectious units of EBOV ( Zaire ebolavirus ). We found that TRIzol LS reagent and RNA-Bee inactivated EBOV in serum; TRIzol LS reagent inactivated EBOV in clarified cell culture media; TRIzol reagent inactivated EBOV in tissue and infected Vero E6 cells; 10% neutral buffered formalin inactivated EBOV in tissue; and osmium tetroxide vapors inactivated EBOV on transmission electron microscopy grids. The methods described herein are easily performed and can be adapted to validate inactivation of viruses in various matrices and by various chemical methods.
Woldetsadik, Mahlet Atakilt; Goggin, Kathy; Staggs, Vincent S; Wanyenze, Rhoda K; Beyeza-Kashesya, Jolly; Mindry, Deborah; Finocchario-Kessler, Sarah; Khanakwa, Sarah; Wagner, Glenn J
2016-06-01
With data from 400 HIV clients with fertility intentions and 57 HIV providers in Uganda, we evaluated the psychometrics of new client and provider scales measuring constructs related to safer conception methods (SCM) and safer conception counselling (SCC). Several forms of validity (i.e., content, face, and construct validity) were examined using standard methods including exploratory and confirmatory factor analysis. Internal consistency was established using Cronbach's alpha correlation coefficient. The final scales consisted of measures of attitudes towards use of SCM and delivery of SCC, including measures of self-efficacy and motivation to use SCM, and perceived community stigma towards childbearing. Most client and all provider measures had moderate to high internal consistency (alphas 0.60-0.94), most had convergent validity (associations with other SCM or SCC-related measures), and client measures had divergent validity (poor associations with depression). These findings establish preliminary psychometric properties of these scales and should facilitate future studies of SCM and SCC.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bentefour, El H., E-mail: hassan.bentefour@iba-group.com; Prieels, Damien; Tang, Shikui
Purpose: In-vivo dosimetry and beam range verification in proton therapy could play significant role in proton treatment validation and improvements. In-vivo beam range verification, in particular, could enable new treatment techniques one of which could be the use of anterior fields for prostate treatment instead of opposed lateral fields as in current practice. This paper reports validation study of an in-vivo range verification method which can reduce the range uncertainty to submillimeter levels and potentially allow for in-vivo dosimetry. Methods: An anthropomorphic pelvic phantom is used to validate the clinical potential of the time-resolved dose method for range verification inmore » the case of prostrate treatment using range modulated anterior proton beams. The method uses a 3 × 4 matrix of 1 mm diodes mounted in water balloon which are read by an ADC system at 100 kHz. The method is first validated against beam range measurements by dose extinction measurements. The validation is first completed in water phantom and then in pelvic phantom for both open field and treatment field configurations. Later, the beam range results are compared with the water equivalent path length (WEPL) values computed from the treatment planning system XIO. Results: Beam range measurements from both time-resolved dose method and the dose extinction method agree with submillimeter precision in water phantom. For the pelvic phantom, when discarding two of the diodes that show sign of significant range mixing, the two methods agree with ±1 mm. Only a dose of 7 mGy is sufficient to achieve this result. The comparison to the computed WEPL by the treatment planning system (XIO) shows that XIO underestimates the protons beam range. Quantifying the exact XIO range underestimation depends on the strategy used to evaluate the WEPL results. To our best evaluation, XIO underestimates the treatment beam range between a minimum of 1.7% and maximum of 4.1%. Conclusions: Time-resolved dose measurement method satisfies the two basic requirements, WEPL accuracy and minimum dose, necessary for clinical use, thus, its potential for in-vivo protons range verification. Further development is needed, namely, devising a workflow that takes into account the limits imposed by proton range mixing and the susceptibility of the comparison of measured and expected WEPLs to errors on the detector positions. The methods may also be used for in-vivo dosimetry and could benefit various proton therapy treatments.« less
NASA Technical Reports Server (NTRS)
Gault, J. W. (Editor); Trivedi, K. S. (Editor); Clary, J. B. (Editor)
1980-01-01
The validation process comprises the activities required to insure the agreement of system realization with system specification. A preliminary validation methodology for fault tolerant systems documented. A general framework for a validation methodology is presented along with a set of specific tasks intended for the validation of two specimen system, SIFT and FTMP. Two major areas of research are identified. First, are those activities required to support the ongoing development of the validation process itself, and second, are those activities required to support the design, development, and understanding of fault tolerant systems.
Tan, Zhirong; Ouyang, Dongsheng; Chen, Yao; Zhou, Gan; Cao, Shan; Wang, Yicheng; Peng, Xiujuan; Zhou, Honghao
2010-08-01
A sensitive and specific liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS/MS) method has been developed and validated for the identification and quantification of clebopride in human plasma using itopride as an internal standard. The method involves a simple liquid-liquid extraction. The analytes were separated by isocratic gradient elution on a CAPCELL MG-III C(18) (5 microm, 150 mm x 2.1 mm i.d.) column and analyzed in multiple reaction monitoring (MRM) mode with positive electrospray ionization (ESI) interface using the respective [M+H](+) ions, m/z 373.9-->m/z184.0 for clebopride, m/z 359.9-->m/z71.5 for itopride. The method was validated over the concentration range of 69.530-4450.0 pg/ml for clebopride. Within- and between-batch precision (RSD%) was all within 6.83% and accuracy ranged from -8.16 to 1.88%. The LLOQ was 69.530 pg/ml. The extraction recovery was on an average 77% for clebopride. The validated method was used to study the pharmacokinetics profile of clebopride in human plasma after oral administration of clebopride. Copyright 2010. Published by Elsevier B.V.
The Arthroscopic Surgical Skill Evaluation Tool (ASSET)
Koehler, Ryan J.; Amsdell, Simon; Arendt, Elizabeth A; Bisson, Leslie J; Braman, Jonathan P; Butler, Aaron; Cosgarea, Andrew J; Harner, Christopher D; Garrett, William E; Olson, Tyson; Warme, Winston J.; Nicandri, Gregg T.
2014-01-01
Background Surgeries employing arthroscopic techniques are among the most commonly performed in orthopaedic clinical practice however, valid and reliable methods of assessing the arthroscopic skill of orthopaedic surgeons are lacking. Hypothesis The Arthroscopic Surgery Skill Evaluation Tool (ASSET) will demonstrate content validity, concurrent criterion-oriented validity, and reliability, when used to assess the technical ability of surgeons performing diagnostic knee arthroscopy on cadaveric specimens. Study Design Cross-sectional study; Level of evidence, 3 Methods Content validity was determined by a group of seven experts using a Delphi process. Intra-articular performance of a right and left diagnostic knee arthroscopy was recorded for twenty-eight residents and two sports medicine fellowship trained attending surgeons. Subject performance was assessed by two blinded raters using the ASSET. Concurrent criterion-oriented validity, inter-rater reliability, and test-retest reliability were evaluated. Results Content validity: The content development group identified 8 arthroscopic skill domains to evaluate using the ASSET. Concurrent criterion-oriented validity: Significant differences in total ASSET score (p<0.05) between novice, intermediate, and advanced experience groups were identified. Inter-rater reliability: The ASSET scores assigned by each rater were strongly correlated (r=0.91, p <0.01) and the intra-class correlation coefficient between raters for the total ASSET score was 0.90. Test-retest reliability: there was a significant correlation between ASSET scores for both procedures attempted by each individual (r = 0.79, p<0.01). Conclusion The ASSET appears to be a useful, valid, and reliable method for assessing surgeon performance of diagnostic knee arthroscopy in cadaveric specimens. Studies are ongoing to determine its generalizability to other procedures as well as to the live OR and other simulated environments. PMID:23548808
Remote sensing imagery classification using multi-objective gravitational search algorithm
NASA Astrophysics Data System (ADS)
Zhang, Aizhu; Sun, Genyun; Wang, Zhenjie
2016-10-01
Simultaneous optimization of different validity measures can capture different data characteristics of remote sensing imagery (RSI) and thereby achieving high quality classification results. In this paper, two conflicting cluster validity indices, the Xie-Beni (XB) index and the fuzzy C-means (FCM) (Jm) measure, are integrated with a diversity-enhanced and memory-based multi-objective gravitational search algorithm (DMMOGSA) to present a novel multi-objective optimization based RSI classification method. In this method, the Gabor filter method is firstly implemented to extract texture features of RSI. Then, the texture features are syncretized with the spectral features to construct the spatial-spectral feature space/set of the RSI. Afterwards, cluster of the spectral-spatial feature set is carried out on the basis of the proposed method. To be specific, cluster centers are randomly generated initially. After that, the cluster centers are updated and optimized adaptively by employing the DMMOGSA. Accordingly, a set of non-dominated cluster centers are obtained. Therefore, numbers of image classification results of RSI are produced and users can pick up the most promising one according to their problem requirements. To quantitatively and qualitatively validate the effectiveness of the proposed method, the proposed classification method was applied to classifier two aerial high-resolution remote sensing imageries. The obtained classification results are compared with that produced by two single cluster validity index based and two state-of-the-art multi-objective optimization algorithms based classification results. Comparison results show that the proposed method can achieve more accurate RSI classification.
A statistical approach to selecting and confirming validation targets in -omics experiments
2012-01-01
Background Genomic technologies are, by their very nature, designed for hypothesis generation. In some cases, the hypotheses that are generated require that genome scientists confirm findings about specific genes or proteins. But one major advantage of high-throughput technology is that global genetic, genomic, transcriptomic, and proteomic behaviors can be observed. Manual confirmation of every statistically significant genomic result is prohibitively expensive. This has led researchers in genomics to adopt the strategy of confirming only a handful of the most statistically significant results, a small subset chosen for biological interest, or a small random subset. But there is no standard approach for selecting and quantitatively evaluating validation targets. Results Here we present a new statistical method and approach for statistically validating lists of significant results based on confirming only a small random sample. We apply our statistical method to show that the usual practice of confirming only the most statistically significant results does not statistically validate result lists. We analyze an extensively validated RNA-sequencing experiment to show that confirming a random subset can statistically validate entire lists of significant results. Finally, we analyze multiple publicly available microarray experiments to show that statistically validating random samples can both (i) provide evidence to confirm long gene lists and (ii) save thousands of dollars and hundreds of hours of labor over manual validation of each significant result. Conclusions For high-throughput -omics studies, statistical validation is a cost-effective and statistically valid approach to confirming lists of significant results. PMID:22738145
Akram, A J; Ireland, A J; Postlethwaite, K C; Sandy, J R; Jerreat, A S
2013-11-01
This article describes the process of validity and reliability testing of a condition-specific quality-of-life measure for patients with hypodontia presenting for orthodontic treatment. The development of the instrument is described in a previous article. Royal Devon and Exeter NHS Foundation Trust & Musgrove Park Hospital, Taunton. The child perception questionnaire was used as a standard against which to test criterion validity. The Bland and Altman method was used to check agreement between the two questionnaires. Construct validity was tested using principal component analysis on the four sections of the questionnaire. Test-retest reliability was tested using intraclass correlation coefficient and Bland and Altman method. Cronbach's alpha was used to test internal consistency reliability. Overall the questionnaire showed good reliability, criterion and construct validity. This together with previous evidence of good face and content validity suggests that the instrument may prove useful in clinical practice and further research. This study has demonstrated that the newly developed condition-specific quality-of-life questionnaire is both valid and reliable for use in young patients with hypodontia. © 2013 John Wiley & Sons A/S. Published by Blackwell Publishing Ltd.
A Validation Study of the Impression Replica Technique.
Segerström, Sofia; Wiking-Lima de Faria, Johanna; Braian, Michael; Ameri, Arman; Ahlgren, Camilla
2018-04-17
To validate the well-known and often-used impression replica technique for measuring fit between a preparation and a crown in vitro. The validation consisted of three steps. First, a measuring instrument was validated to elucidate its accuracy. Second, a specimen consisting of male and female counterparts was created and validated by the measuring instrument. Calculations were made for the exact values of three gaps between the male and female. Finally, impression replicas were produced of the specimen gaps and sectioned into four pieces. The replicas were then measured with the use of a light microscope. The values received from measuring the specimen were then compared with the values received from the impression replicas, and the technique was thereby validated. The impression replica technique overvalued all measured gaps. Depending on location of the three measuring sites, the difference between the specimen and the impression replicas varied from 47 to 130 μm. The impression replica technique overestimates gaps within the range of 2% to 11%. The validation of the replica technique enables the method to be used as a reference when testing other methods for evaluating fit in dentistry. © 2018 by the American College of Prosthodontists.
Lin, Yuanjie; Feng, Chao; Xu, Qian; Lu, Dasheng; Qiu, Xinlei; Jin, Yu'e; Wang, Guoquan; Wang, Dongli; She, Jianwen; Zhou, Zhijun
2016-07-01
An improved method based on tandem solid phase extraction (SPE) cleanup and gas chromatography-high resolution mass spectrometry (GC-HRMS) has been validated for a rapid determination of dibenzo-p-dioxins/furans (PCDD/Fs), dioxin-like polychlorinated biphenyls (PCBs), marker polychlorinated biphenyls (M-PCBs), and polybrominated diphenyl ethers (PBDEs) using a large volume (50 mL) of human milk. This method was well validated for the measurement of these analytes in human milk from the general population with low limits of detection (LODs, 0.004-0.12 ng/g lipid), satisfactory accuracy (75-120 % of recoveries), and precision [less than 10 % of relative standard deviations (RSDs)]. To comprehensively evaluate the performance of this method, a good, presently validated and routinely used method based on an automated sample clean-up system (ASCS, based on the commercial acid multilayer silica, basic alumina, and carbon columns) was used in parallel for comparison. Compared with the ASCS method, this method presented comparable specificity. Additionally, this method, in contrast to ASCS method, highly reduced consumption of solvents (40 mL versus 500 mL), which results in much lower background in the procedural blank, reduced time, and enhanced sample pretreatment throughput. This method was also applied in a pilot study to measure a batch of human milk samples with satisfactory results. Graphical Abstract Characteristics of the application of tandem SPE cleanup for determination of PCDD/Fs, DL-PCBs,M-PCBs and PBDEs in human milk.
Hollands, Wendy J; Voorspoels, Stefan; Jacobs, Griet; Aaby, Kjersti; Meisland, Ane; Garcia-Villalba, Rocio; Tomas-Barberan, Francisco; Piskula, Mariusz K; Mawson, Deborah; Vovk, Irena; Needs, Paul W; Kroon, Paul A
2017-04-28
There is a lack of data for individual oligomeric procyanidins in apples and apple extracts. Our aim was to develop, validate and evaluate an analytical method for the separation, identification and quantification of monomeric and oligomeric flavanols in apple extracts. To achieve this, we prepared two types of flavanol extracts from freeze-dried apples; one was an epicatechin-rich extract containing ∼30% (w/w) monomeric (-)-epicatechin which also contained oligomeric procyanidins (Extract A), the second was an oligomeric procyanidin-rich extract depleted of epicatechin (Extract B). The parameters considered for method optimisation were HPLC columns and conditions, sample heating, mass of extract and dilution volumes. The performance characteristics considered for method validation included standard linearity, method sensitivity, precision and trueness. Eight laboratories participated in the method evaluation. Chromatographic separation of the analytes was best achieved utilizing a Hilic column with a binary mobile phase consisting of acidic acetonitrile and acidic aqueous methanol. The final method showed linearity for epicatechin in the range 5-100μg/mL with a correlation co-efficient >0.999. Intra-day and inter-day precision of the analytes ranged from 2 to 6% and 2 to 13% respectively. Up to dp3, trueness of the method was >95% but decreased with increasing dp. Within laboratory precision showed RSD values <5 and 10% for monomers and oligomers, respectively. Between laboratory precision was 4 and 15% (Extract A) and 7 and 30% (Extract B) for monomers and oligomers, respectively. An analytical method for the separation, identification and quantification of procyanidins in an apple extract was developed, validated and assessed. The results of the inter-laboratory evaluation indicate that the method is reliable and reproducible. Copyright © 2017. Published by Elsevier B.V.
Martín-Sabroso, Cristina; Tavares-Fernandes, Daniel Filipe; Espada-García, Juan Ignacio; Torres-Suárez, Ana Isabel
2013-12-15
In this work a protocol to validate analytical procedures for the quantification of drug substances formulated in polymeric systems that comprise both drug entrapped into the polymeric matrix (assay:content test) and drug released from the systems (assay:dissolution test) is developed. This protocol is applied to the validation two isocratic HPLC analytical procedures for the analysis of dexamethasone phosphate disodium microparticles for parenteral administration. Preparation of authentic samples and artificially "spiked" and "unspiked" samples is described. Specificity (ability to quantify dexamethasone phosphate disodium in presence of constituents of the dissolution medium and other microparticle constituents), linearity, accuracy and precision are evaluated, in the range from 10 to 50 μg mL(-1) in the assay:content test procedure and from 0.25 to 10 μg mL(-1) in the assay:dissolution test procedure. The robustness of the analytical method to extract drug from microparticles is also assessed. The validation protocol developed allows us to conclude that both analytical methods are suitable for their intended purpose, but the lack of proportionality of the assay:dissolution analytical method should be taken into account. The validation protocol designed in this work could be applied to the validation of any analytical procedure for the quantification of drugs formulated in controlled release polymeric microparticles. Copyright © 2013 Elsevier B.V. All rights reserved.
A study in the founding of applied behavior analysis through its publications.
Morris, Edward K; Altus, Deborah E; Smith, Nathaniel G
2013-01-01
This article reports a study of the founding of applied behavior analysis through its publications. Our methods included hand searches of sources (e.g., journals, reference lists), search terms (i.e., early, applied, behavioral, research, literature), inclusion criteria (e.g., the field's applied dimension), and (d) challenges to their face and content validity. Our results were 36 articles published between 1959 and 1967 that we organized into 4 groups: 12 in 3 programs of research and 24 others. Our discussion addresses (a) limitations in our method (e.g., the completeness of our search), (b) challenges to the validity of our methods and results (e.g., convergent validity), and (c) priority claims about the field's founding. We conclude that the claims are irresolvable because identification of the founding publications depends significantly on methods and because the field's founding was an evolutionary process. We close with suggestions for future research.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Geisler-Moroder, David; Lee, Eleanor S.; Ward, Gregory J.
2016-08-29
The Five-Phase Method (5-pm) for simulating complex fenestration systems with Radiance is validated against field measurements. The capability of the method to predict workplane illuminances, vertical sensor illuminances, and glare indices derived from captured and rendered high dynamic range (HDR) images is investigated. To be able to accurately represent the direct sun part of the daylight not only in sensor point simulations, but also in renderings of interior scenes, the 5-pm calculation procedure was extended. The validation shows that the 5-pm is superior to the Three-Phase Method for predicting horizontal and vertical illuminance sensor values as well as glare indicesmore » derived from rendered images. Even with input data from global and diffuse horizontal irradiance measurements only, daylight glare probability (DGP) values can be predicted within 10% error of measured values for most situations.« less
Validation of a method for the quantitation of ghrelin and unacylated ghrelin by HPLC.
Staes, Edith; Rozet, Eric; Ucakar, Bernard; Hubert, Philippe; Préat, Véronique
2010-02-05
An HPLC/UV method was first optimized for the separation and quantitation of human acylated and unacylated (or des-acyl) ghrelin from aqueous solutions. This method was validated by an original approach using accuracy profiles based on tolerance intervals for the total error measurement. The concentration range that achieved adequate accuracy extended from 1.85 to 59.30microM and 1.93 to 61.60microM for acylated and unacylated ghrelin, respectively. Then, optimal temperature, pH and buffer for sample storage were determined. Unacylated ghrelin was found to be stable in all conditions tested. At 37 degrees C acylated ghrelin was stable at pH 4 but unstable at pH 7.4, the main degradation product was unacylated ghrelin. Finally, this validated HPLC/UV method was used to evaluate the binding of acylated and unacylated ghrelin to liposomes.
Forward ultrasonic model validation using wavefield imaging methods
NASA Astrophysics Data System (ADS)
Blackshire, James L.
2018-04-01
The validation of forward ultrasonic wave propagation models in a complex titanium polycrystalline material system is accomplished using wavefield imaging methods. An innovative measurement approach is described that permits the visualization and quantitative evaluation of bulk elastic wave propagation and scattering behaviors in the titanium material for a typical focused immersion ultrasound measurement process. Results are provided for the determination and direct comparison of the ultrasonic beam's focal properties, mode-converted shear wave position and angle, and scattering and reflection from millimeter-sized microtexture regions (MTRs) within the titanium material. The approach and results are important with respect to understanding the root-cause backscatter signal responses generated in aerospace engine materials, where model-assisted methods are being used to understand the probabilistic nature of the backscatter signal content. Wavefield imaging methods are shown to be an effective means for corroborating and validating important forward model predictions in a direct manner using time- and spatially-resolved displacement field amplitude measurements.
NASA Technical Reports Server (NTRS)
Lyle, Karen H.
2014-01-01
Acceptance of new spacecraft structural architectures and concepts requires validated design methods to minimize the expense involved with technology validation via flighttesting. This paper explores the implementation of probabilistic methods in the sensitivity analysis of the structural response of a Hypersonic Inflatable Aerodynamic Decelerator (HIAD). HIAD architectures are attractive for spacecraft deceleration because they are lightweight, store compactly, and utilize the atmosphere to decelerate a spacecraft during re-entry. However, designers are hesitant to include these inflatable approaches for large payloads or spacecraft because of the lack of flight validation. In the example presented here, the structural parameters of an existing HIAD model have been varied to illustrate the design approach utilizing uncertainty-based methods. Surrogate models have been used to reduce computational expense several orders of magnitude. The suitability of the design is based on assessing variation in the resulting cone angle. The acceptable cone angle variation would rely on the aerodynamic requirements.
A Study in the Founding of Applied Behavior Analysis Through Its Publications
Morris, Edward K.; Altus, Deborah E.; Smith, Nathaniel G.
2013-01-01
This article reports a study of the founding of applied behavior analysis through its publications. Our methods included hand searches of sources (e.g., journals, reference lists), search terms (i.e., early, applied, behavioral, research, literature), inclusion criteria (e.g., the field's applied dimension), and (d) challenges to their face and content validity. Our results were 36 articles published between 1959 and 1967 that we organized into 4 groups: 12 in 3 programs of research and 24 others. Our discussion addresses (a) limitations in our method (e.g., the completeness of our search), (b) challenges to the validity of our methods and results (e.g., convergent validity), and (c) priority claims about the field's founding. We conclude that the claims are irresolvable because identification of the founding publications depends significantly on methods and because the field's founding was an evolutionary process. We close with suggestions for future research. PMID:25729133
Validity of Willingness to Pay Measures under Preference Uncertainty.
Braun, Carola; Rehdanz, Katrin; Schmidt, Ulrich
2016-01-01
Recent studies in the marketing literature developed a new method for eliciting willingness to pay (WTP) with an open-ended elicitation format: the Range-WTP method. In contrast to the traditional approach of eliciting WTP as a single value (Point-WTP), Range-WTP explicitly allows for preference uncertainty in responses. The aim of this paper is to apply Range-WTP to the domain of contingent valuation and to test for its theoretical validity and robustness in comparison to the Point-WTP. Using data from two novel large-scale surveys on the perception of solar radiation management (SRM), a little-known technique for counteracting climate change, we compare the performance of both methods in the field. In addition to the theoretical validity (i.e. the degree to which WTP values are consistent with theoretical expectations), we analyse the test-retest reliability and stability of our results over time. Our evidence suggests that the Range-WTP method clearly outperforms the Point-WTP method.
Multimethod Investigation of Interpersonal Functioning in Borderline Personality Disorder
Stepp, Stephanie D.; Hallquist, Michael N.; Morse, Jennifer Q.; Pilkonis, Paul A.
2011-01-01
Even though interpersonal functioning is of great clinical importance for patients with borderline personality disorder (BPD), the comparative validity of different assessment methods for interpersonal dysfunction has not yet been tested. This study examined multiple methods of assessing interpersonal functioning, including self- and other-reports, clinical ratings, electronic diaries, and social cognitions in three groups of psychiatric patients (N=138): patients with (1) BPD, (2) another personality disorder, and (3) Axis I psychopathology only. Using dominance analysis, we examined the predictive validity of each method in detecting changes in symptom distress and social functioning six months later. Across multiple methods, the BPD group often reported higher interpersonal dysfunction scores compared to other groups. Predictive validity results demonstrated that self-report and electronic diary ratings were the most important predictors of distress and social functioning. Our findings suggest that self-report scores and electronic diary ratings have high clinical utility, as these methods appear most sensitive to change. PMID:21808661
Optimization and validation of a minicolumn method for determining aflatoxins in copra meal.
Arim, R H; Aguinaldo, A R; Tanaka, T; Yoshizawa, T
1999-01-01
A minicolumn (MC) method for determining aflatoxins in copra meal was optimized and validated. The method uses methanol-4% KCl solution as extractant and CuSO4 solution as clarifying agent. The chloroform extract is applied to an MC that incorporates "lahar," an indigenous material, as substitute for silica gel. The "lahar"-containing MC produces a more distinct and intense blue fluoresence on the Florisil layer than an earlier MC. The method has a detection limit of 15 micrograms total aflatoxins/kg sample. Confirmatory tests using 50% H2SO4 and trifluoroacetic acid in benzene with 25% HNO3 showed that copra meal samples contained aflatoxins and no interfering agents. The MC responses of the copra meal samples were in good agreement with their behavior in thin-layer chromatography. This modified MC method is accurate, giving linearity-valid results; rapid, being done in 15 min; economical, using low-volume reagents; relatively safe, having low-exposure risk of analysts to chemicals; and simple, making its field application feasible.
Imputation of missing data in time series for air pollutants
NASA Astrophysics Data System (ADS)
Junger, W. L.; Ponce de Leon, A.
2015-02-01
Missing data are major concerns in epidemiological studies of the health effects of environmental air pollutants. This article presents an imputation-based method that is suitable for multivariate time series data, which uses the EM algorithm under the assumption of normal distribution. Different approaches are considered for filtering the temporal component. A simulation study was performed to assess validity and performance of proposed method in comparison with some frequently used methods. Simulations showed that when the amount of missing data was as low as 5%, the complete data analysis yielded satisfactory results regardless of the generating mechanism of the missing data, whereas the validity began to degenerate when the proportion of missing values exceeded 10%. The proposed imputation method exhibited good accuracy and precision in different settings with respect to the patterns of missing observations. Most of the imputations obtained valid results, even under missing not at random. The methods proposed in this study are implemented as a package called mtsdi for the statistical software system R.
Validity of Willingness to Pay Measures under Preference Uncertainty
Braun, Carola; Rehdanz, Katrin; Schmidt, Ulrich
2016-01-01
Recent studies in the marketing literature developed a new method for eliciting willingness to pay (WTP) with an open-ended elicitation format: the Range-WTP method. In contrast to the traditional approach of eliciting WTP as a single value (Point-WTP), Range-WTP explicitly allows for preference uncertainty in responses. The aim of this paper is to apply Range-WTP to the domain of contingent valuation and to test for its theoretical validity and robustness in comparison to the Point-WTP. Using data from two novel large-scale surveys on the perception of solar radiation management (SRM), a little-known technique for counteracting climate change, we compare the performance of both methods in the field. In addition to the theoretical validity (i.e. the degree to which WTP values are consistent with theoretical expectations), we analyse the test-retest reliability and stability of our results over time. Our evidence suggests that the Range-WTP method clearly outperforms the Point-WTP method. PMID:27096163