Sample records for methods including ms

  1. METHOD 544. DETERMINATION OF MICROCYSTINS AND NODULARIN IN DRINKING WATER BY SOLID PHASE EXTRACTION AND LIQUID CHROMATOGRAPHY/TANDEM MASS SPECTROMETRY (LC/MS/MS)

    EPA Science Inventory

    Method 544 is an accurate and precise analytical method to determine six microcystins (including MC-LR) and nodularin in drinking water using solid phase extraction and liquid chromatography tandem mass spectrometry (SPE-LC/MS/MS). The advantage of this SPE-LC/MS/MS is its sensi...

  2. Online immunoaffinity LC/MS/MS. A general method to increase sensitivity and specificity: How do you do it and what do you need?

    PubMed

    Dufield, Dawn R; Radabaugh, Melissa R

    2012-02-01

    There is an increased emphasis on hyphenated techniques such as immunoaffinity LC/MS/MS (IA-LC/MS/MS) or IA-LC/MRM. These techniques offer competitive advantages with respect to sensitivity and selectivity over traditional LC/MS and are complementary to ligand binding assays (LBA) or ELISA's. However, these techniques are not entirely straightforward and there are several tips and tricks to routine sample analysis. We describe here our methods and procedures for how to perform online IA-LC/MS/MS including a detailed protocol for the preparation of antibody (Ab) enrichment columns. We have included sample trapping and Ab methods. Furthermore, we highlight tips, tricks, minimal and optimal approaches. This technology has been shown to be viable for several applications, species and fluids from small molecules to proteins and biomarkers to PK assays. Copyright © 2011 Elsevier Inc. All rights reserved.

  3. DETERMINATION OF ECOLOGICALLY RELEVANT PHARMACEUTICALS AND THEIR SELECTED METABOLITES IN EFFLUENT AND SURFACE WATER USING UPLC/MS/MS

    EPA Science Inventory

    Objective is to develop analytical methods including SPE and UPLC/MS/MS needed to analyze over 60 human prescription pharamceuticals and metabolites belonging to a multitude of different classes in surface waters and wastewater effluent. The methods will be used in future studies...

  4. New Method for the Analysis of Flukicide and Other Anthelmintic Residues in Bovine Milk and Liver using LC-MS/MS

    USDA-ARS?s Scientific Manuscript database

    A liquid chromatographic-tandem mass spectrometric (LC-MS/MS) multi-residue method for the simultaneous quantification and identification of 38 residues of the most widely used anthelmintic veterinary drugs (including benzimidazoles, macrocyclic lactones, and flukicides) in milk and liver has been d...

  5. Practical Methods for Including Torsional Anharmonicity in Thermochemical Calculations on Complex Molecules: The Internal-Coordinate Multi-Structural Approximation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zheng, J.; Yu, T.; Papajak, E.

    2011-01-01

    Many methods for correcting harmonic partition functions for the presence of torsional motions employ some form of one-dimensional torsional treatment to replace the harmonic contribution of a specific normal mode. However, torsions are often strongly coupled to other degrees of freedom, especially other torsions and low-frequency bending motions, and this coupling can make assigning torsions to specific normal modes problematic. Here, we present a new class of methods, called multi-structural (MS) methods, that circumvents the need for such assignments by instead adjusting the harmonic results by torsional correction factors that are determined using internal coordinates. We present three versions ofmore » the MS method: (i) MS-AS based on including all structures (AS), i.e., all conformers generated by internal rotations; (ii) MS-ASCB based on all structures augmented with explicit conformational barrier (CB) information, i.e., including explicit calculations of all barrier heights for internal-rotation barriers between the conformers; and (iii) MS-RS based on including all conformers generated from a reference structure (RS) by independent torsions. In the MS-AS scheme, one has two options for obtaining the local periodicity parameters, one based on consideration of the nearly separable limit and one based on strongly coupled torsions. The latter involves assigning the local periodicities on the basis of Voronoi volumes. The methods are illustrated with calculations for ethanol, 1-butanol, and 1-pentyl radical as well as two one-dimensional torsional potentials. The MS-AS method is particularly interesting because it does not require any information about conformational barriers or about the paths that connect the various structures.« less

  6. Practical methods for including torsional anharmonicity in thermochemical calculations on complex molecules: the internal-coordinate multi-structural approximation.

    PubMed

    Zheng, Jingjing; Yu, Tao; Papajak, Ewa; Alecu, I M; Mielke, Steven L; Truhlar, Donald G

    2011-06-21

    Many methods for correcting harmonic partition functions for the presence of torsional motions employ some form of one-dimensional torsional treatment to replace the harmonic contribution of a specific normal mode. However, torsions are often strongly coupled to other degrees of freedom, especially other torsions and low-frequency bending motions, and this coupling can make assigning torsions to specific normal modes problematic. Here, we present a new class of methods, called multi-structural (MS) methods, that circumvents the need for such assignments by instead adjusting the harmonic results by torsional correction factors that are determined using internal coordinates. We present three versions of the MS method: (i) MS-AS based on including all structures (AS), i.e., all conformers generated by internal rotations; (ii) MS-ASCB based on all structures augmented with explicit conformational barrier (CB) information, i.e., including explicit calculations of all barrier heights for internal-rotation barriers between the conformers; and (iii) MS-RS based on including all conformers generated from a reference structure (RS) by independent torsions. In the MS-AS scheme, one has two options for obtaining the local periodicity parameters, one based on consideration of the nearly separable limit and one based on strongly coupled torsions. The latter involves assigning the local periodicities on the basis of Voronoi volumes. The methods are illustrated with calculations for ethanol, 1-butanol, and 1-pentyl radical as well as two one-dimensional torsional potentials. The MS-AS method is particularly interesting because it does not require any information about conformational barriers or about the paths that connect the various structures.

  7. Nanoparticle-assisted laser desorption/ionization mass spectrometry: Novel sample preparation methods and nanoparticle screening for plant metabolite imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yagnik, Gargey B.

    The main goal of the presented research is development of nanoparticle based matrix-assisted laser desorption ionization-mass spectrometry (MALDI-MS). This dissertation includes the application of previously developed data acquisition methods, development of novel sample preparation methods, application and comparison of novel nanoparticle matrices, and comparison of two nanoparticle matrix application methods for MALDI-MS and MALDI-MS imaging.

  8. Sensitivity of GC-EI/MS, GC-EI/MS/MS, LC-ESI/MS/MS, LC-Ag(+) CIS/MS/MS, and GC-ESI/MS/MS for analysis of anabolic steroids in doping control.

    PubMed

    Cha, Eunju; Kim, Sohee; Kim, Ho Jun; Lee, Kang Mi; Kim, Ki Hun; Kwon, Oh-Seung; Lee, Jaeick

    2015-01-01

    This study compared the sensitivity of various separation and ionization methods, including gas chromatography with an electron ionization source (GC-EI), liquid chromatography with an electrospray ionization source (LC-ESI), and liquid chromatography with a silver ion coordination ion spray source (LC-Ag(+) CIS), coupled to a mass spectrometer (MS) for steroid analysis. Chromatographic conditions, mass spectrometric transitions, and ion source parameters were optimized. The majority of steroids in GC-EI/MS/MS and LC-Ag(+) CIS/MS/MS analysis showed higher sensitivities than those obtained with other analytical methods. The limits of detection (LODs) of 65 steroids by GC-EI/MS/MS, 68 steroids by LC-Ag(+) CIS/MS/MS, 56 steroids by GC-EI/MS, 54 steroids by LC-ESI/MS/MS, and 27 steroids by GC-ESI/MS/MS were below cut-off value of 2.0 ng/mL. LODs of steroids that formed protonated ions in LC-ESI/MS/MS analysis were all lower than the cut-off value. Several steroids such as unconjugated C3-hydroxyl with C17-hydroxyl structure showed higher sensitivities in GC-EI/MS/MS analysis relative to those obtained using the LC-based methods. The steroids containing 4, 9, 11-triene structures showed relatively poor sensitivities in GC-EI/MS and GC-ESI/MS/MS analysis. The results of this study provide information that may be useful for selecting suitable analytical methods for confirmatory analysis of steroids. Copyright © 2015 John Wiley & Sons, Ltd.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Busbey, A.B.

    A number of methods and products, both hardware and software, to allow data exchange between Apple Macintosh computers and MS-DOS based systems. These included serial null modem connections, MS-DOS hardware and/or software emulation, MS-DOS disk-reading hardware and networking.

  10. High Throughput Analytical Techniques for the Determination and Confirmation of Residues of 653 Multiclass Pesticides and Chemical Pollutants in Tea by GC/MS, GC/MS/MS, and LC/MS/MS: Collaborative Study, First Action 2014.09.

    PubMed

    Pang, Guo-Fang; Fan, Chun-Lin; Cao, Yan-Zhong; Yan, Fang; Li, Yan; Kang, Jian; Chen, Hui; Chang, Qiao-Ying

    2015-01-01

    Thirty laboratories from fom North and South America, Europe, and Asia participated in this AOAC collaborative study (15 from China; five from Germany; two each from Italy and the United States; and one each from the Republic of Korea, Canada, Spain, Japan, Belgium, and India). Participants represented government regulatory, commercial testing, university, research institute, and private laboratories. The single-laboratory validated (SLV) tea method was evaluated in the collaborative study to determine the recovery and reproducibility of the method under multilaboratory conditions. Since there were no restrictions regarding the type of analytical instrumentation to use for the analyses, laboratories used a combination of equipment that included GC/MS, GC/MS/MS, and LC/MS/MS instruments from 22 different manufacturers, 21 brands of GC and LC columns, 13 different GC temperature programming profiles, 11 LC gradient elution programs, and six different vendor manufactured SPE cartridges. Even though all the analytical performance parameters for all the 653 compounds had been determined in the SLV study, guidance was obtained from an expert review panel of the AOAC Method-Centric Committee on Pesticide Residues to conduct the multilaboratory collaborative study based on 20 selected compounds that can be analyzed by GC/MS and 20 compounds that can be analyzed by LC/MS/MS. Altogether, 560 samples covering the 40 selected pesticides were analyzed in the study. These samples included green tea and oolong tea samples fortified typically at the European Union maximum residue limit for regulatory guidance and compliance, aged tea samples incurred with 20 pesticides, and green tea and oolong tea samples incurred with five pesticides. The analysis of the 560 samples generated a total of 82 459 test results by the 30 participating laboratories. One laboratory failed to meet the proficiency requirements in the precollaborative study. Therefore, its data submitted for the collaborative study were excluded from further analysis and interpretation. The results presented are therefore the 6638 analytical results obtained from the 29 remaining laboratories, which included 1977 results generated by GC/MS, 1704 results by GC/MS/MS, and 2957 results by LC/MS/MS. It was determined after application of the Grubbs and Dixon tests for outliers to the data sets that there were 65 outlier results from the 1977 GC/MS results (3.3%), 65 outlier results from the 1704 GC/MS/MS results (3.8%), and 57 outlier results out of 2957 LC/MS/MS results (1.9%), representing 0.98, 0.98, and 0.86%, respectively, of the 6638 results generated in the study. Analysis with the AOAC statistical software package also confirmed that the method is rugged, and average recovery, average concentration, RSDr, RSDR, and HorRat values all meet recovery and reproducibility criteria for use in multiple laboratories. The Study Director is recommending this method for adoption as an AOAC First Action Official MethodSM.

  11. Resolution and Assignment of Differential Ion Mobility Spectra of Sarcosine and Isomers.

    PubMed

    Berthias, Francis; Maatoug, Belkis; Glish, Gary L; Moussa, Fathi; Maitre, Philippe

    2018-04-01

    Due to their central role in biochemical processes, fast separation and identification of amino acids (AA) is of importance in many areas of the biomedical field including the diagnosis and monitoring of inborn errors of metabolism and biomarker discovery. Due to the large number of AA together with their isomers and isobars, common methods of AA analysis are tedious and time-consuming because they include a chromatographic separation step requiring pre- or post-column derivatization. Here, we propose a rapid method of separation and identification of sarcosine, a biomarker candidate of prostate cancer, from isomers using differential ion mobility spectrometry (DIMS) interfaced with a tandem mass spectrometer (MS/MS) instrument. Baseline separation of protonated sarcosine from α- and β-alanine isomers can be easily achieved. Identification of DIMS peak is performed using an isomer-specific activation mode where DIMS- and mass-selected ions are irradiated at selected wavenumbers allowing for the specific fragmentation via an infrared multiple photon dissociation (IRMPD) process. Two orthogonal methods to MS/MS are thus added, where the MS/MS(IRMPD) is nothing but an isomer-specific multiple reaction monitoring (MRM) method. The identification relies on the comparison of DIMS-MS/MS(IRMPD) chromatograms recorded at different wavenumbers. Based on the comparison of IR spectra of the three isomers, it is shown that specific depletion of the two protonated α- and β-alanine can be achieved, thus allowing for clear identification of the sarcosine peak. It is also demonstrated that DIMS-MS/MS(IRMPD) spectra in the carboxylic C=O stretching region allow for the resolution of overlapping DIMS peaks. Graphical Abstract ᅟ.

  12. Liquid-phase microextraction for rapid AP-MALDI and quantitation of nortriptyline in biological matrices.

    PubMed

    Wu, Hui-Fen; Ku, Hsin-Yi; Yen, Jyh-Hao

    2008-07-01

    A liquid-phase microextraction (LPME) method using a micropipette with disposable tips was demonstrated for coupling to atmospheric pressure MALDI-MS (AP-MALDI/MS) as a concentrating probe for rapid analysis and quantitative determination of nortriptyline drug from biological matrices including human urine and human plasma. This technique was named as micropipette extraction (MPE). The best optimized parameters of MPE coupled to AP-MALDI/MS experiments were extraction solvent, toluene; extraction time, 5 min; sample agitation rate, 480 rpm; sample pH, 7; salt concentration, 30%; hole size of micropipette tips, 0.61 mm (id); and matrix concentration, 1000 ppm using alpha-cyano-4-hydroxycinnamic acid (CHCA) as a matrix. Three detection modes of AP-MALDI/MS analysis including full scan, selective ion monitor (SIM), and selective reaction monitor (SRM) of MS/MS were also compared for the MPE performance. The results clearly demonstrated that the MS/MS method provides a wider linear range and lower LODs but poor RSDs than the full scan and SIM methods. The LOD values for the MPE under SIM and MS/MS modes in water, urine, and plasma were 6.26, 47.5, and 94.9 nM, respectively. The enrichment factors (EFs) of this current approach were 36.5-43.0 fold in water. In addition, compared to single drop microextraction (SDME) and LPME using a dual gauge microsyringe with a hollow fiber (LPME-HF) technique, the LODs acquired by the MPE method under MS/MS modes were comparable to those of LPME-HF and SDME but it is more convenient than both methods. The advantages of this novel method are simple, easy to use, low cost, and no contamination between experiments since disposable tips were used for the micropipettes. The MPE has the potential to be widely used in the future because it only requires a simple micropipette to perform all extraction processes. We believe that this technique can be a powerful tool for MALDI/MS analysis of biological samples and clinical applications.

  13. Sharpening advanced land imager multispectral data using a sensor model

    USGS Publications Warehouse

    Lemeshewsky, G.P.; ,

    2005-01-01

    The Advanced Land Imager (ALI) instrument on NASA's Earth Observing One (EO-1) satellite provides for nine spectral bands at 30m ground sample distance (GSD) and a 10m GSD panchromatic band. This report describes an image sharpening technique where the higher spatial resolution information of the panchromatic band is used to increase the spatial resolution of ALI multispectral (MS) data. To preserve the spectral characteristics, this technique combines reported deconvolution deblurring methods for the MS data with highpass filter-based fusion methods for the Pan data. The deblurring process uses the point spread function (PSF) model of the ALI sensor. Information includes calculation of the PSF from pre-launch calibration data. Performance was evaluated using simulated ALI MS data generated by degrading the spatial resolution of high resolution IKONOS satellite MS data. A quantitative measure of performance was the error between sharpened MS data and high resolution reference. This report also compares performance with that of a reported method that includes PSF information. Preliminary results indicate improved sharpening with the method reported here.

  14. A simple, rapid atmospheric pressure chemical ionization liquid chromatography tandem mass spectrometry method for the determination of 25-hydroxyvitamin D2 and D3.

    PubMed

    Garg, Uttam; Munar, Ada; Frazee, Clinton; Scott, David

    2012-09-01

    Vitamin D plays a vital role not only in bone health but also in pathophysiology of many other body functions. In recent years, there has been significant increase in testing of 25-hydroxyvitamin D (25-OH vitamin D), a marker of vitamin D deficiency. The most commonly used methods for the measurement of 25-OH vitamin D are immunoassays and liquid chromatography tandem mass spectrometry (LC-MS-MS). Since immunoassays suffer from inaccuracies and interferences, LC-MS-MS is a preferred method. In LC-MS-MS methods, 25-OH vitamin D is extracted from serum or plasma by solid-phase or liquid-phase extraction. Because these extraction methods are time consuming, we developed an easy method that uses simple protein precipitation followed by injection of the supernatant to LC-MS-MS. Several mass-to-charge (m/z) ratio transitions, including commonly used transitions based on water loss, were evaluated and several tube types were tested. The optimal transitions for 25-OH vitamin D2 and D3 were 395.5 > 269.5 and 383.4 > 257.3, respectively. The reportable range of the method was 1-100 ng/mL, and repeatability (within-run) and within-laboratory imprecision were <4% and <6%, respectively. The method agreed well with the solid-phase extraction methods. © 2012 Wiley Periodicals, Inc.

  15. Resolution and Assignment of Differential Ion Mobility Spectra of Sarcosine and Isomers

    NASA Astrophysics Data System (ADS)

    Berthias, Francis; Maatoug, Belkis; Glish, Gary L.; Moussa, Fathi; Maitre, Philippe

    2018-02-01

    Due to their central role in biochemical processes, fast separation and identification of amino acids (AA) is of importance in many areas of the biomedical field including the diagnosis and monitoring of inborn errors of metabolism and biomarker discovery. Due to the large number of AA together with their isomers and isobars, common methods of AA analysis are tedious and time-consuming because they include a chromatographic separation step requiring pre- or post-column derivatization. Here, we propose a rapid method of separation and identification of sarcosine, a biomarker candidate of prostate cancer, from isomers using differential ion mobility spectrometry (DIMS) interfaced with a tandem mass spectrometer (MS/MS) instrument. Baseline separation of protonated sarcosine from α- and β-alanine isomers can be easily achieved. Identification of DIMS peak is performed using an isomer-specific activation mode where DIMS- and mass-selected ions are irradiated at selected wavenumbers allowing for the specific fragmentation via an infrared multiple photon dissociation (IRMPD) process. Two orthogonal methods to MS/MS are thus added, where the MS/MS(IRMPD) is nothing but an isomer-specific multiple reaction monitoring (MRM) method. The identification relies on the comparison of DIMS-MS/MS(IRMPD) chromatograms recorded at different wavenumbers. Based on the comparison of IR spectra of the three isomers, it is shown that specific depletion of the two protonated α- and β-alanine can be achieved, thus allowing for clear identification of the sarcosine peak. It is also demonstrated that DIMS-MS/MS(IRMPD) spectra in the carboxylic C=O stretching region allow for the resolution of overlapping DIMS peaks. [Figure not available: see fulltext.

  16. Simultaneous determination of rhamnose, xylitol, arabitol, fructose, glucose, inositol, sucrose, maltose in jujube (Zizyphus jujube Mill.) extract: comparison of HPLC-ELSD, LC-ESI-MS/MS and GC-MS.

    PubMed

    Sun, Shihao; Wang, Hui; Xie, Jianping; Su, Yue

    2016-01-01

    Jujube extract is commonly used as a food additive and flavoring. The sensory properties of the extract, especially sweetness, are a critical factor determining the product quality and therefore affecting consumer acceptability. Small molecular carbohydrates make major contribution to the sweetness of the jujube extract, and their types and contents in the extract have direct influence on quality of the product. So, an appropriate qualitative and quantitative method for determination of the carbohydrates is vitally important for quality control of the product. High performance liquid chromatography-evaporative light scattering detection (HPLC-ELSD), liquid chromatography-electronic spay ionization tandem mass spectrometry (LC-ESI-MS/MS), and gas chromatography-mass spectrometry (GC-MS) methods have been developed and applied to determining small molecular carbohydrates in jujube extract, respectively. Eight sugars and alditols were identified from the extract, including rhamnose, xylitol, arabitol, fructose, glucose, inositol, sucrose, and maltose. Comparisons were carried out to investigate the performance of the methods. Although the methods have been found to perform satisfactorily, only three sugars (fructose, glucose and inositol) could be detected by all these methods. Meanwhile, a similar quantitative result for the three sugars can be obtained by the methods. Eight sugars and alditols in the jujube extract were determined by HPLC-ELSD, LC-ESI-MS/MS and GC-MS, respectively. The LC-ELSD method and the LC-ESI-MS/MS method with good precision and accuracy were suitable for quantitative analysis of carbohydrates in jujube extract; although the performance of the GC-MS method for quantitative analysis was inferior to the other methods, it has a wider scope in qualitative analysis. A multi-analysis technique should be adopted in order to obtain complete constituents of about the carbohydrates in jujube extract, and the methods should be employed according to the purpose of analysis.

  17. LC-MS n Analysis of Isomeric Chondroitin Sulfate Oligosaccharides Using a Chemical Derivatization Strategy

    NASA Astrophysics Data System (ADS)

    Huang, Rongrong; Pomin, Vitor H.; Sharp, Joshua S.

    2011-09-01

    Improved methods for structural analyses of glycosaminoglycans (GAGs) are required to understand their functional roles in various biological processes. Major challenges in structural characterization of complex GAG oligosaccharides using liquid chromatography-mass spectrometry (LC-MS) include the accurate determination of the patterns of sulfation due to gas-phase losses of the sulfate groups upon collisional activation and inefficient on-line separation of positional sulfation isomers prior to MS/MS analyses. Here, a sequential chemical derivatization procedure including permethylation, desulfation, and acetylation was demonstrated to enable both on-line LC separation of isomeric mixtures of chondroitin sulfate (CS) oligosaccharides and accurate determination of sites of sulfation by MS n . The derivatized oligosaccharides have sulfate groups replaced with acetyl groups, which are sufficiently stable to survive MS n fragmentation and reflect the original sulfation patterns. A standard reversed-phase LC-MS system with a capillary C18 column was used for separation, and MS n experiments using collision-induced dissociation (CID) were performed. Our results indicate that the combination of this derivatization strategy and MS n methodology enables accurate identification of the sulfation isomers of CS hexasaccharides with either saturated or unsaturated nonreducing ends. Moreover, derivatized CS hexasaccharide isomer mixtures become separable by LC-MS method due to different positions of acetyl modifications.

  18. Improved profiling of estrogen metabolites by orbitrap LC/MS

    PubMed Central

    Li, Xingnan; Franke, Adrian A.

    2015-01-01

    Estrogen metabolites are important biomarkers to evaluate cancer risks and metabolic diseases. Due to their low physiological levels, a sensitive and accurate method is required, especially for the quantitation of unconjugated forms of endogenous steroids and their metabolites in humans. Here, we evaluated various derivatives of estrogens for improved analysis by orbitrap LC/MS in human serum samples. A new chemical derivatization reagent was applied modifying phenolic steroids to form 1-methylimidazole-2-sulfonyl adducts. The method significantly improves the sensitivity 2–100 fold by full scan MS and targeted selected ion monitoring MS over other derivatization methods including, dansyl, picolinoyl, and pyridine-3-sulfonyl products. PMID:25543003

  19. Results of the first provisional technical secretariat interlaboratory comparison test

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stuff, J.R.; Hoffland, L.

    1995-06-01

    The principal task of this laboratory in the first Provisional Technical Secretariat (PTS) Interlaboratory Comparison Test was to verify and test the extraction and preparation procedures outlined in the Recommended Operating Procedures for Sampling and Analysis in the Verification of Chemical Disarmament in addition to our laboratory extraction methods and our laboratory analysis methods. Sample preparation began on 16 May 1994 and analysis was completed on 12 June 1994. The analytical methods used included NMR ({sup 1}H and {sup 31}P) GC/AED, GC/MS (EI and methane CI), GC/IRD, HPLC/IC, HPLC/TSP/MS, MS/MS(Electrospray), and CZE.

  20. Mass spectrometry and immunoassay: how to measure steroid hormones today and tomorrow.

    PubMed

    Taylor, Angela E; Keevil, Brian; Huhtaniemi, Ilpo T

    2015-08-01

    The recent onslaught of mass spectrometry (MS) to measurements of steroid hormones, including demands that they should be the only acceptable method, has confused clinicians and scientists who have relied for more than 40 years on a variety of immunoassay (IA) methods in steroid hormone measurements. There is little doubt that MS methods with their superior specificity will be the future method of choice in many clinical and research applications of steroid hormone measurement. However, the majority of steroid measurements are currently, and will continue to be, carried out using various types of IAs for several reasons, including their technical ease, cost and availability of commercial reagents. Speedy replacement of all IAs with MS is an unrealistic and unnecessary goal, because the availability of MS measurements is limited by cost, need of expensive equipment, technical demands and lack of commercial applications. Furthermore, IAs have multiple well-known advantages that vindicate their continuing use. The purpose of this article is to elucidate the advantages and limitations of the MS and IA techniques from two angles, i.e. promotion of MS and defence of IA. The purpose of the text is to give the reader an unbiased view about the current state and future trends of steroid analysis and to help him/her choose the correct assay method to serve his/her diagnostic and research needs. © 2015 European Society of Endocrinology.

  1. Laser desorption ionization and peptide sequencing on laser induced silicon microcolumn arrays

    DOEpatents

    Vertes, Akos [Reston, VA; Chen, Yong [San Diego, CA

    2011-12-27

    The present invention provides a method of producing a laser-patterned silicon surface, especially silicon wafers for use in laser desorption ionization (LDI-MS) (including MALDI-MS and SELDI-MS), devices containing the same, and methods of testing samples employing the same. The surface is prepared by subjecting a silicon substrate to multiple laser shots from a high-power picosecond or femtosecond laser while in a processing environment, e.g., underwater, and generates a remarkable homogenous microcolumn array capable of providing an improved substrate for LDI-MS.

  2. A simple validated multi-analyte method for detecting drugs in oral fluid by ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS).

    PubMed

    Zheng, Yufang; Sparve, Erik; Bergström, Mats

    2018-06-01

    A UPLC-MS/MS method was developed to identify and quantitate 37 commonly abused drugs in oral fluid. Drugs of interest included amphetamines, benzodiazepines, cocaine, opiates, opioids, phencyclidine and tetrahydrocannabinol. Sample preparation and extraction are simple, and analysis times short. Validation showed satisfactory performance at relevant concentrations. The possibility of contaminated samples as well as the interpretation in relation to well-knows matrices, such as urine, will demand further study. Copyright © 2017 John Wiley & Sons, Ltd.

  3. METHOD 544. DETERMINATION OF MICROCYSTINS AND ...

    EPA Pesticide Factsheets

    Method 544 is an accurate and precise analytical method to determine six microcystins (including MC-LR) and nodularin in drinking water using solid phase extraction and liquid chromatography tandem mass spectrometry (SPE-LC/MS/MS). The advantage of this SPE-LC/MS/MS is its sensitivity and ability to speciate the microcystins. This method development task establishes sample preservation techniques, sample concentration and analytical procedures, aqueous and extract holding time criteria and quality control procedures. Draft Method 544 undergone a multi-laboratory verification to ensure other laboratories can implement the method and achieve the quality control measures specified in the method. It is anticipated that Method 544 may be used in UCMR 4 to collect nationwide occurrence data for selected microcystins in drinking water. The purpose of this research project is to develop an accurate and precise analytical method to concentrate and determine selected MCs and nodularin in drinking water.

  4. Chemical fingerprinting and quantitative constituent analysis of Siwu decoction categorized formulae by UPLC-QTOF/MS/MS and HPLC-DAD

    PubMed Central

    2013-01-01

    Background Siwu decoction categorized formulae (SWDCF) are widely used for treating gynecological diseases. This study aims to elucidate the differences of bioactive constituents in SWDCF by ultra-high performance liquid chromatography coupled with time-of-flight mass spectrometry (UPLC - QTOF - MS /MS) and HPLC-DAD. Methods An efficient method based on UPLC - QTOF - MS /MS was developed for identifying the chemical profiles of SWDCF. HPLC-DAD method was used for quantifying seven chemical markers in SWDCF. Results Eighty four components were identified or characterized, including ten organic acids, thirty glycosides (monoterpene or iridoid or phenylpropanoids glycosides), fourteen lactones, eighteen flavonoids, and eleven alkaloids in the complex system. The datasets of tR-m/z pairs, ion intensities and sample codes were processed with supervised orthogonal partial least squared discriminant analysis to compare these decoction samples. After a clear classification was established, OPLS-DA was performed and 16 common components with relative quantity in SWDCF samples were determined. Gallic acid, protocatechuic acid, vanillic acid, caffeic acid, paeoniflorin, ferulic acid, and senkyunolide I were selected as the chemical markers to identify SWDCF by HPLC-DAD. Conclusion The chemical profiles with 84 components in SWDCF, including monoterpene glycosides, acetophenones, galloyl glucoses, even some isomers in the complex system were characterized by UPLC–QTOF–MS/MS. PMID:23453004

  5. Expansion of the Scope of AOAC First Action Method 2012.25--Single-Laboratory Validation of Triphenylmethane Dye and Leuco Metabolite Analysis in Shrimp, Tilapia, Catfish, and Salmon by LC-MS/MS.

    PubMed

    Andersen, Wendy C; Casey, Christine R; Schneider, Marilyn J; Turnipseed, Sherri B

    2015-01-01

    Prior to conducting a collaborative study of AOAC First Action 2012.25 LC-MS/MS analytical method for the determination of residues of three triphenylmethane dyes (malachite green, crystal violet, and brilliant green) and their metabolites (leucomalachite green and leucocrystal violet) in seafood, a single-laboratory validation of method 2012.25 was performed to expand the scope of the method to other seafood matrixes including salmon, catfish, tilapia, and shrimp. The validation included the analysis of fortified and incurred residues over multiple weeks to assess analyte stability in matrix at -80°C, a comparison of calibration methods over the range 0.25 to 4 μg/kg, study of matrix effects for analyte quantification, and qualitative identification of targeted analytes. Method accuracy ranged from 88 to 112% with 13% RSD or less for samples fortified at 0.5, 1.0, and 2.0 μg/kg. Analyte identification and determination limits were determined by procedures recommended both by the U. S. Food and Drug Administration and the European Commission. Method detection limits and decision limits ranged from 0.05 to 0.24 μg/kg and 0.08 to 0.54 μg/kg, respectively. AOAC First Action Method 2012.25 with an extracted matrix calibration curve and internal standard correction is suitable for the determination of triphenylmethane dyes and leuco metabolites in salmon, catfish, tilapia, and shrimp by LC-MS/MS at a residue determination level of 0.5 μg/kg or below.

  6. Development of liquid chromatography-tandem mass spectrometry methods for the quantitation of Anisakis simplex proteins in fish.

    PubMed

    Fæste, Christiane Kruse; Moen, Anders; Schniedewind, Björn; Haug Anonsen, Jan; Klawitter, Jelena; Christians, Uwe

    2016-02-05

    The parasite Anisakis simplex is present in many marine fish species that are directly used as food or in processed products. The anisakid larvae infect mostly the gut and inner organs of fish but have also been shown to penetrate into the fillet. Thus, human health can be at risk, either by contracting anisakiasis through the consumption of raw or under-cooked fish, or by sensitisation to anisakid proteins in processed food. A number of different methods for the detection of A. simplex in fish and products thereof have been developed, including visual techniques and PCR for larvae tracing, and immunological assays for the determination of proteins. The recent identification of a number of anisakid proteins by mass spectrometry-based proteomics has laid the groundwork for the development of two quantitative liquid chromatography-tandem mass spectrometry methods for the detection of A. simplex in fish that are described in the present study. Both, the label-free semi-quantitative nLC-nESI-Orbitrap-MS/MS (MS1) and the heavy peptide-applying absolute-quantitative (AQUA) LC-TripleQ-MS/MS (MS2) use unique reporter peptides derived from anisakid hemoglobin and SXP/RAL-2 protein as analytes. Standard curves in buffer and in salmon matrix showed limits of detection at 1μg/mL and 10μg/mL for MS1 and 0.1μg/mL and 2μg/mL for MS2. Preliminary method validation included the assessment of sensitivity, repeatability, reproducibility, and applicability to incurred and naturally-contaminated samples for both assays. By further optimization and full validation in accordance with current recommendations the LC-MS/MS methods could be standardized and used generally as confirmative techniques for the detection of A. simplex protein in fish. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Determination of nicotianamine in soy sauce and other plant-based foods by LC-MS/MS.

    PubMed

    Yamaguchi, Hitomi; Uchida, Riichiro

    2012-10-10

    Nicotianamine is a nonproteinogenic amino acid, known to be an important metal chelator in plants. Recently, the antihypertensive effect of nicotianamine was discovered. In this study, a simple method to determine nicotianamine was developed using liquid chromatography-tandem mass spectrometry (LC-MS/MS) with a multimode ODS column. This method does not need derivatizing or ion-pairing reagents to retain nicotianamine, which is known for its poor retention on reversed-phase columns because of its high polarity. Moreover, this method showed a sufficient limit of detection (0.5 ng/mL), so it was found to be suitable for the analysis of nicotianamine in soy sauce and other foods, without cleanup. To subtract the matrix effect during LC-MS/MS analysis, a standard addition method was used. The levels of nicotianamine in soy sauce ranged from <0.25 to 71 μg/g. Nicotianamine was also determined in other foods, including soy milk, vegetable juice, fruit juice, and bottled tea.

  8. Multiplexed Post-Experimental Monoisotopic Mass Refinement ( m PE-MMR) to Increase Sensitivity and Accuracy in Peptide Identifications from Tandem Mass Spectra of Cofragmentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Madar, Inamul Hasan; Ko, Seung-Ik; Kim, Hokeun

    Mass spectrometry (MS)-based proteomics, which uses high-resolution hybrid mass spectrometers such as the quadrupole-orbitrap mass spectrometer, can yield tens of thousands of tandem mass (MS/MS) spectra of high resolution during a routine bottom-up experiment. Despite being a fundamental and key step in MS-based proteomics, the accurate determination and assignment of precursor monoisotopic masses to the MS/MS spectra remains difficult. The difficulties stem from imperfect isotopic envelopes of precursor ions, inaccurate charge states for precursor ions, and cofragmentation. We describe a composite method of utilizing MS data to assign accurate monoisotopic masses to MS/MS spectra, including those subject to cofragmentation. Themore » method, “multiplexed post-experiment monoisotopic mass refinement” (mPE-MMR), consists of the following: multiplexing of precursor masses to assign multiple monoisotopic masses of cofragmented peptides to the corresponding multiplexed MS/MS spectra, multiplexing of charge states to assign correct charges to the precursor ions of MS/ MS spectra with no charge information, and mass correction for inaccurate monoisotopic peak picking. When combined with MS-GF+, a database search algorithm based on fragment mass difference, mPE-MMR effectively increases both sensitivity and accuracy in peptide identification from complex high-throughput proteomics data compared to conventional methods.« less

  9. Development of a liquid chromatography-tandem mass spectrometry method for quantitative analysis of trace d-amino acids.

    PubMed

    Nakano, Yosuke; Konya, Yutaka; Taniguchi, Moyu; Fukusaki, Eiichiro

    2017-01-01

    d-Amino acids have recently attracted much attention in various research fields including medical, clinical and food industry due to their important biological functions that differ from l-amino acid. Most chiral amino acid separation techniques require complicated derivatization procedures in order to achieve the desirable chromatographic behavior and detectability. Thus, the aim of this research is to develop a highly sensitive analytical method for the enantioseparation of chiral amino acids without any derivatization process using liquid chromatography-tandem mass spectrometry (LC-MS/MS). By optimizing MS/MS parameters, we established a quantification method that allowed the simultaneous analysis of 18 d-amino acids with high sensitivity and reproducibility. Additionally, we applied the method to food sample (vinegar) for the validation, and successfully quantified trace levels of d-amino acids in samples. These results demonstrated the applicability and feasibility of the LC-MS/MS method as a novel, effective tool for d-amino acid measurement in various biological samples. Copyright © 2016 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  10. A fast and reliable method for GHB quantitation in whole blood by GC-MS/MS (TQD) for forensic purposes.

    PubMed

    Castro, André L; Tarelho, Sónia; Dias, Mário; Reis, Flávio; Teixeira, Helena M

    2016-02-05

    Gamma-hydroxybutyric acid (GHB) is an endogenous compound with a story of clinical use since the 1960s. However, due to its secondary effects, it has become a controlled substance, entering the illicit market. A fully validated, sensitive and reproducible method for the quantification of GHB by methanolic precipitation and GC-MS/MS (TQD) in whole blood is presented. Using 100μL of whole blood, obtained results included a LOD and LLOQ of 0.1mg/L and a recovery of 86% in a working range between 0.1 and 100mg/L. This method is sensitive and specific to detect the presence of GHB in small amounts of whole blood (both ante-mortem or post-mortem), and is, to the authors' knowledge, the first GC-MS-MS TQD method that uses different precursor ions and product ions for the identification of GHB and GHB-D6 (internal standard). Hence, this method may be especially useful for the study of endogenous values in this biological sample. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. New Method for Analysis of Multiple Anthelmintic Residues in Animal Tissue

    USDA-ARS?s Scientific Manuscript database

    For the first time, 39 of the major anthelmintics can be detected in one rapid and sensitive LC-MS/MS method, including the flukicides, which have been generally overlooked in surveillance programs. Utilizing the QuEChERS approach, residues were extracted from liver and milk using acetonitrile, sod...

  12. Rapid method for the measurement of circulating thyroid hormones in low volumes of teleost fish plasma by LC-ESI/MS/MS

    PubMed Central

    Noyes, Pamela D.; Lema, Sean C.; Roberts, Simon C.; Cooper, Ellen M.

    2014-01-01

    Thyroid hormones are critical regulators of normal development and physiological functioning in all vertebrates. Radioimmunoassay (RIA) approaches have been the method of choice for measuring circulating levels of thyroid hormones in vertebrates. While sensitive, RIA-based approaches only allow for a single analyte measurement per assay, can lack concordance across platforms and laboratories, and can be prone to analytical interferences especially when used with fish plasma. Ongoing advances in liquid chromatography tandem mass spectrometry (LC/MS/MS) have led to substantial decreases in detection limits for thyroid hormones and other biomolecules in complex matrices, including human plasma. Despite these advances, current analytical approaches do not allow for the measurement of native thyroid hormone in teleost fish plasma by mass spectrometry and continue to rely on immunoassay. In this study, we developed a new method that allows for the rapid extraction and simultaneous measurement of total T4 (TT4) and total T3 (TT3) in low volumes (50 μL) of fish plasma by LC/MS/MS. Methods were optimized initially in plasma from rainbow trout (Oncorhynchus mykiss) and applied to plasma from other teleost fishes, including fathead minnows (Pimephales promelas), mummichogs (Fundulus heteroclitus), sockeye salmon (Oncorhynchus nerka), and coho salmon (Oncorhynchus kisutch). Validation of method performance with T4- and T3-spiked rainbow trout plasma at 2 and 4 ng/mL produced mean recoveries ranging from 82 to 95 % and 97 to 105 %, respectively. Recovery of 13C12-T4 internal standard in plasma extractions was: 99±1.8 % in rainbow trout, 85±11 % in fathead minnow, 73±5.0 % in mummichog, 73±1.7 % in sockeye salmon, and 80±8.4 % in coho salmon. While absolute levels of thyroid hormones measured in identical plasma samples by LC/MS/MS and RIA varied depending on the assay used, T4/T3 ratios were generally consistent across both techniques. Less variability was measured among samples subjected to LC/MS/MS suggesting a more precise estimate of thyroid hormone homeostasis in the species targeted. Overall, a sensitive and reproducible method was established that takes advantage of LC/MS/MS techniques to rapidly measure TT4 and TT3 with negligible interferences in low volumes of plasma across a variety of teleost fishes. PMID:24343452

  13. Extending a Tandem Mass Spectral Library to Include MS2 Spectra of Fragment Ions Produced In-Source and MSn Spectra.

    PubMed

    Yang, Xiaoyu; Neta, Pedatsur; Stein, Stephen E

    2017-11-01

    Tandem mass spectral library searching is finding increased use as an effective means of determining chemical identity in mass spectrometry-based omics studies. We previously reported on constructing a tandem mass spectral library that includes spectra for multiple precursor ions for each analyte. Here we report our method for expanding this library to include MS 2 spectra of fragment ions generated during the ionization process (in-source fragment ions) as well as MS 3 and MS 4 spectra. These can assist the chemical identification process. A simple density-based clustering algorithm was used to cluster all significant precursor ions from MS 1 scans for an analyte acquired during an infusion experiment. The MS 2 spectra associated with these precursor ions were grouped into the same precursor clusters. Subsequently, a new top-down hierarchical divisive clustering algorithm was developed for clustering the spectra from fragmentation of ions in each precursor cluster, including the MS 2 spectra of the original precursors and of the in-source fragments as well as the MS n spectra. This algorithm starts with all the spectra of one precursor in one cluster and then separates them into sub-clusters of similar spectra based on the fragment patterns. Herein, we describe the algorithms and spectral evaluation methods for extending the library. The new library features were demonstrated by searching the high resolution spectra of E. coli extracts against the extended library, allowing identification of compounds and their in-source fragment ions in a manner that was not possible before. Graphical Abstract ᅟ.

  14. 77 FR 59578 - Notice of Filing of Several Pesticide Petitions Filed for Residues of Pesticide Chemicals in or...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-28

    ...-nitroguanidine, in or on fruiting, vegetables, group 8-10, except pepper/eggplant subgroup 8-10B at 0.2 ppm; and pepper/eggplant subgroup 8-10B at 0.7 ppm. Adequate enforcement methodology (LC/MS/MS analysis) is... validated, including LC- MS/MS methods for use on tomato, pepper, melon, and cucumber. The analytical...

  15. Use of Imipenem To Detect KPC, NDM, OXA, IMP, and VIM Carbapenemase Activity from Gram-Negative Rods in 75 Minutes Using Liquid Chromatography-Tandem Mass Spectrometry

    PubMed Central

    Kulkarni, M. V.; Zurita, A. N.; Pyka, J. S.; Murray, T. S.; Hodsdon, M. E.

    2014-01-01

    Resistance to extended-spectrum β-lactam antibiotics has led to a greater reliance upon carbapenems, but the expression of carbapenemases threatens to limit the utility of these drugs. Current methods to detect carbapenemase activity are suboptimal, requiring prolonged incubations during which ineffective therapy may be prescribed. We previously described a sensitive and specific assay for the detection of carbapenemase activity using ertapenem and liquid chromatography-tandem mass spectrometry (LC-MS/MS). In this study, we assessed 402 Gram-negative rods, including both Enterobacteriaceae and non-Enterobacteriaceae expressing IMP, VIM, KPC, NDM, and/or OXA carbapenemases, by using imipenem, meropenem, and ertapenem with LC-MS/MS assays. LC-MS/MS methods for the detection of intact and hydrolyzed carbapenems from an enrichment broth were developed. No ion suppression was observed, and the limits of detection for all three drugs were below 0.04 μg/ml. The sensitivity and specificity of meropenem and ertapenem for carbapenemase activity among non-Enterobacteriaceae were low, but imipenem demonstrated a sensitivity and specificity of 96% and 95%, respectively, among all Gram-negative rods (GNR) tested, including both Enterobacteriaceae and non-Enterobacteriaceae. LC-MS/MS allows for the analysis of more complex matrices, and this LC-MS/MS assay could easily be adapted for use with primary specimens requiring growth enrichment. PMID:24789180

  16. Analysis of phytochemical variations in dioecious Tinospora cordifolia stems using HPLC/QTOF MS/MS and UPLC/QqQLIT -MS/MS.

    PubMed

    Bajpai, Vikas; Singh, Awantika; Chandra, Preeti; Negi, M P S; Kumar, Nikhil; Kumar, Brijesh

    2016-01-01

    The stem of dioecious Tinospora cordifolia (Menispermaceae) is a commonly used traditional Ayurvedic medicine in India having several therapeutic properties. To develop and validate LC-MS methods for the identification and simultaneous quantitation of various secondary metabolites and to study metabolomic variations in the stem of male and female plants. Ethanolic extract of stems were analysed by HPLC/ESI-QTOF-MS/MS for rapid screening of bioactive phytochemicals. High resolution MS and MS/MS in positive ESI mode were used for structural investigation of secondary metabolites. An UPLC/ESI-QqQ(LIT) -MS/MS method in MRM mode was developed and validated for the simultaneous quantitation of five bioactive alkaloids. Identification and characterisation of 36 metabolites including alkaloids, sesquiterpenes and phytoecdysteroids were performed using LC-MS and MS/MS techniques. The bioactive alkaloids such as jatrorrhizine, magnoflorine, isocorydine, palmatine and tetrahydropalmatine were successfully quantified in male and female plants. The mean abundances of magnoflorine jatrorrhizine, and oblongine were significantly (P < 0.05) higher in male plants while mean abundances of tetrahydropalmatine, norcoclaurine, and reticuline were significantly (P < 0.05) higher in female plants. Phytochemicals in the stem of male and female Tinospora cordifolia showed significant qualitative and quantitative variations. LC-MS and MS/MS methods can be used to differentiate between male and female plants based on their chemical profiles and quantities of the marker bioactive alkaloids. This chemical composition difference was also evident during vegetative stage when there were no male and female flowers. Copyright © 2015 John Wiley & Sons, Ltd.

  17. Simultaneous determination of 24 polycyclic aromatic hydrocarbons in edible oil by tandem solid-phase extraction and gas chromatography coupled/tandem mass spectrometry.

    PubMed

    Xu, Ting; Tang, Hua; Chen, Dazhou; Dong, Haifeng; Li, Lei

    2015-01-01

    An efficient and fast tandem SPE method followed by GC/MS/MS has been developed for the determination and the quantification of 24 polycyclic aromatic hydrocarbons (PAHs) in edible oil. This method includes the monitoring of 15 + 1 PAHs designated as a priority by the European Union in their 2005/108/EC recommendation and 16 PAHs listed by the U. S. Environmental Protection Agency. The sample preparation procedures were based on SPE in which PAH-dedicated cartridges with molecularly imprinted polymers and graphitized carbon black were used in series. The novel tandem SPE combination of selective extraction and purification of light and heavy PAHs provided highly purified analytes. Identification and quantification of 24 target PAHs were performed using GC/MS/MS with the isotope dilution approaches using D-labeled and (13)C-labeled PAHs. The advantages of GC/MS/MS as compared to other detection methods include high sensitivity, selectivity, and interpretation ability. The method showed satisfactory linearity (R(2) > 0.998) over the range assayed (0.5-200 μg/kg); the LODs ranged from 0.03 to 0.6 μg/kg, and LOQs from 0.1 to 2.0 μg/kg. The recoveries using this method at three spiked concentration levels (2, 10, and 50 μg/kg) ranged from 56.8 to 117.7%. The RSD was lower than 12.7% in all cases. The proposed analytical method has been successfully applied for the analysis of the 24 PAHs in edible oil.

  18. Analysis of heparin oligosaccharides by capillary electrophoresis-negative-ion electrospray ionization mass spectrometry.

    PubMed

    Lin, Lei; Liu, Xinyue; Zhang, Fuming; Chi, Lianli; Amster, I Jonathan; Leach, Franklyn E; Xia, Qiangwei; Linhardt, Robert J

    2017-01-01

    Most hyphenated analytical approaches that rely on liquid chromatography-MS require relatively long separation times, produce incomplete resolution of oligosaccharide mixtures, use eluents that are incompatible with electrospray ionization, or require oligosaccharide derivatization. Here we demonstrate the analysis of heparin oligosaccharides, including disaccharides, ultralow molecular weight heparin, and a low molecular weight heparin, using a novel electrokinetic pump-based CE-MS coupling eletrospray ion source. Reverse polarity CE separation and negative-mode electrospray ionization were optimized using a volatile methanolic ammonium acetate electrolyte and sheath fluid. The online CE hyphenated negative-ion electrospray ionization MS on an LTQ Orbitrap mass spectrometer was useful in disaccharide compositional analysis and bottom-up and top-down analysis of low molecular weight heparin. The application of this CE-MS method to ultralow molecular heparin suggests that a charge state distribution and the low level of sulfate group loss that is achieved make this method useful for online tandem MS analysis of heparins. Graphical abstract Most hyphenated analytical approaches that rely on liquid chromatography-MS require relatively long separation times, produce incomplete resolution of oligosaccharide mixtures, use eluents that are incompatible with electrospray ionization, or require oligosaccharide derivatization. Here we demonstrate the analysis of heparin oligosaccharides, including disaccharides, ultralow molecular weight heparin, and a low molecular weight heparin, using a novel electrokinetic pump-based CE-MS coupling eletrospray ion source. Reverse polarity CE separation and negative-mode electrospray ionization were optimized using a volatile methanolic ammonium acetate electrolyte and sheath fluid. The online CE hyphenated negative-ion electrospray ionization MS on an LTQ Orbitrap mass spectrometer was useful in disaccharide compositional analysis and bottom-up and top-down analysis of low molecular weight heparin. The application of this CE-MS method to ultralow molecular heparin suggests that a charge state distribution and the low level of sulfate group loss that is achieved make this method useful for online tandem MS analysis of heparins.

  19. Validation of amino-acids measurement in dried blood spot by FIA-MS/MS for PKU management.

    PubMed

    Bruno, C; Dufour-Rainfray, D; Patin, F; Vourc'h, P; Guilloteau, D; Maillot, F; Labarthe, F; Tardieu, M; Andres, C R; Emond, P; Blasco, H

    2016-09-01

    Phenylketonuria (PKU) is a metabolic disorder leading to high concentrations of phenylalanine (Phe) and low concentrations of tyrosine (Tyr) in blood and brain that may be neurotoxic. This disease requires a regular monitoring of plasma Phe and Tyr as well as branched-chain amino-acids concentrations to adapt the Phe-restricted diet and other therapy that may be prescribed in PKU. We validated a Flow Injection Analysis tandem Mass Spectrometry (FIA-MS/MS) to replace the enzymatic method routinely used for neonatal screening in order to monitor in parallel to Phe, Tyr and branched-chain amino-acids not detected by the enzymatic method. We ascertained the performances of the method: linearity, detection and quantification limits, contamination index, accuracy. We cross validated the FIA-MS/MS and enzymatic methods and we evaluated our own reference ranges to monitor Phe, Tyr, Leu, Val on 59 dried blood spots of normal controls. We also evaluated Tyr, Leu and Val concentrations in PKU patients to detect some potential abnormalities, not evaluated by the enzymatic method. We developed a rapid method with excellent performances including precision and accuracy <15%. We noted an excellent correlation of Phe concentrations between FIA-MS/MS and enzymatic methods (p<0.0001) based on our database which are similar to references ranges published. We observed that 50% of PKU patients had lower concentrations of Tyr, Leu and/or Val that could not be detected by the enzymatic method. Based on laboratory accreditation recommendations, we validated a robust, rapid and reliable FIA-MS/MS method to monitor plasma Phe concentrations but also Tyr, Leu and Val concentrations, suitable for PKU management. We evaluated our own reference ranges of concentration for a routine application of this method. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  20. Acrylamide: formation, occurrence in food products, detection methods, and legislation.

    PubMed

    Arvanitoyannis, Ioannis S; Dionisopoulou, Niki

    2014-01-01

    This review aims at summarizing the most recent updates in the field of acrylamide (AA) formation (mechanism, conditions) and the determination of AA in a number of foods (fried or baked potatoes, chips, coffee, bread, etc). The methods applied for AA detection [Capillary Electrophoresis-Mass Spectrometry (CE-MS), Liquid Chromatography-Mass Spectrometry (LC-MS), Non-Aqueous Capillary Electrophoresis (NACE), High Performance Liquid Chromatography-Mass Spectrometry (HPLC-MS), Pressurized Fluid Extraction (PFE), Matrix Solid-Phase Dispersion (MSPD), Gas Chromatography-Mass Spectrometry (GC-MS), Solid-Phase MicroExtraction-Gas Chromatography (SPME-GC), Enzyme Linked Immunosorbent Assay (ELISA), and MicroEmulsion ElectroKinetic Chromatography (MEEKC) are presented and commented. Several informative figures and tables are included to show the effect of conditions (temperature, time) on the AA formation. A section is also included related to AA legislation in EU and US.

  1. Quantification of mevalonate-5-phosphate using UPLC-MS/MS for determination of mevalonate kinase activity.

    PubMed

    Reitzle, Lukas; Maier, Barbara; Stojanov, Silvia; Teupser, Daniel; Muntau, Ania C; Vogeser, Michael; Gersting, Søren W

    2015-08-01

    Mevalonate kinase deficiency, a rare autosomal recessive autoinflammatory disease, is caused by mutations in the MVK gene encoding mevalonate kinase (MK). MK catalyzes the phosphorylation of mevalonic acid to mevalonate-5-phosphate (MVAP) in the pathway of isoprenoid and sterol synthesis. The disease phenotype correlates with residual activity ranging from <0.5% for mevalonic aciduria to 1-7% for the milder hyperimmunoglobulinemia D and periodic fever syndrome (HIDS). Hence, assessment of loss-of-function requires high accuracy measurements. We describe a method using isotope dilution UPLC-MS/MS for precise and sensitive determination of MK activity. Wild-type MK and the variant V261A, which is associated with HIDS, were recombinantly expressed in Escherichia coli. Enzyme activity was determined by formation of MVAP over time quantified by isotope dilution UPLC-MS/MS. The method was validated according to the FDA Guidance for Bioanalytical Method Validation. Sensitivity for detection of MAVP by UPLC-MS/MS was improved by derivatization with butanol-HCl (LLOQ, 5.0 fmol) and the method was linear from 0.5 to 250 μmol/L (R(2) > 0.99) with a precision of ≥ 89% and an accuracy of ± 2.7%. The imprecision of the activity assay, including the enzymatic reaction and the UPLC-MS/MS quantification, was 8.3%. The variant V261A showed a significantly decreased activity of 53.1%. Accurate determination of MK activity was enabled by sensitive and reproducible detection of MVAP using UPLC-MS/MS. The novel method may improve molecular characterization of MVK mutations, provide robust genotype-phenotype correlations, and accelerate compound screening for drug candidates restoring variant MK activity. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  2. Determination of five tetracyclines and their epimers by LC-MS/MS based on a liquid-liquid extraction with low temperature partitioning.

    PubMed

    Desmarchelier, Aurélien; Anizan, Sébastien; Minh Tien, Mai; Savoy, Marie-Claude; Bion, Cindy

    2018-04-01

    An LC-MS/MS method is presented for screening five tetracyclines and their epimers in a broad range of food products. The scope of matrices includes meat-, fish-, seafood-based products, various dairy ingredients, infant formulae and fats. The method principle is based on a liquid-liquid extraction with aqueous ethylenediaminetetraacetic acid (EDTA) and acetonitrile followed by a freezing step to promote phase separation at low temperature. After defatting with hexane, sample extracts were evaporated and reconstituted before injection onto the LC-MS/MS system. The addition of oxalic acid in the aqueous mobile phase was mandatory to maintain good peak shape and sensitivity over the run. The screening is based upon a double preparation of each sample, one 'as such' and a second one with the analytes spiked in the sample, in order to mitigate the risk of false negative response. The method was validated according to the European Community Reference Laboratories Residues Guidelines. A total of 93 samples were included in the validation by two independent laboratories giving both false-negative and false-positive rates at 0% for all compounds. Over the last two years, 2600 samples were analysed routinely and only one chicken sample was found above the regulatory limit.

  3. The use of lithiated adducts for structural analysis of acylglycerols by MS-ESI

    USDA-ARS?s Scientific Manuscript database

    Electrospray ionization mass spectrometry (ESI-MS) using lithium adducts is the method of choice for the analysis of acyglycerols. The method can be used for the identification of the structures of fatty acid constituents, including the number and location of double bonds and hydroxyl groups. The me...

  4. Segmental analysis of amphetamines in hair using a sensitive UHPLC-MS/MS method.

    PubMed

    Jakobsson, Gerd; Kronstrand, Robert

    2014-06-01

    A sensitive and robust ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed and validated for quantification of amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine and 3,4-methylenedioxy methamphetamine in hair samples. Segmented hair (10 mg) was incubated in 2M sodium hydroxide (80°C, 10 min) before liquid-liquid extraction with isooctane followed by centrifugation and evaporation of the organic phase to dryness. The residue was reconstituted in methanol:formate buffer pH 3 (20:80). The total run time was 4 min and after optimization of UHPLC-MS/MS-parameters validation included selectivity, matrix effects, recovery, process efficiency, calibration model and range, lower limit of quantification, precision and bias. The calibration curve ranged from 0.02 to 12.5 ng/mg, and the recovery was between 62 and 83%. During validation the bias was less than ±7% and the imprecision was less than 5% for all analytes. In routine analysis, fortified control samples demonstrated an imprecision <13% and control samples made from authentic hair demonstrated an imprecision <26%. The method was applied to samples from a controlled study of amphetamine intake as well as forensic hair samples previously analyzed with an ultra high performance liquid chromatography time of flight mass spectrometry (UHPLC-TOF-MS) screening method. The proposed method was suitable for quantification of these drugs in forensic cases including violent crimes, autopsy cases, drug testing and re-granting of driving licences. This study also demonstrated that if hair samples are divided into several short segments, the time point for intake of a small dose of amphetamine can be estimated, which might be useful when drug facilitated crimes are investigated. Copyright © 2014 John Wiley & Sons, Ltd.

  5. Recent advances in CE-MS coupling: Instrumentation, methodology, and applications.

    PubMed

    Týčová, Anna; Ledvina, Vojtěch; Klepárník, Karel

    2017-01-01

    This review focuses on the latest development of microseparation electromigration methods in capillaries and microfluidic devices coupled with MS for detection and identification of important analytes. It is a continuation of the review article on the same topic by Kleparnik (Electrophoresis 2015, 36, 159-178). A wide selection of 161 relevant articles covers the literature published from June 2014 till May 2016. New improvements in the instrumentation and methodology of MS interfaced with capillary or microfluidic versions of zone electrophoresis, isotachophoresis, and isoelectric focusing are described in detail. The most frequently implemented MS ionization methods include electrospray ionization, matrix-assisted desorption/ionization and inductively coupled plasma ionization. Although the main attention is paid to the development of instrumentation and methodology, representative examples illustrate also applications in the proteomics, glycomics, metabolomics, biomarker research, forensics, pharmacology, food analysis, and single-cell analysis. The combinations of MS with capillary versions of electrochromatography, and micellar electrokinetic chromatography are not included. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. A selective and sensitive method for quantitation of lysergic acid diethylamide (LSD) in whole blood by gas chromatography-ion trap tandem mass spectrometry.

    PubMed

    Libong, Danielle; Bouchonnet, Stéphane; Ricordel, Ivan

    2003-01-01

    A gas chromatography-ion trap tandem mass spectrometry (GC-ion trap MS-MS) method for detection and quantitation of LSD in whole blood is presented. The sample preparation process, including a solid-phase extraction step with Bond Elut cartridges, was performed with 2 mL of whole blood. Eight microliters of the purified extract was injected with a cold on-column injection method. Positive chemical ionization was performed using acetonitrile as reagent gas; LSD was detected in the MS-MS mode. The chromatograms obtained from blood extracts showed the great selectivity of the method. GC-MS quantitation was performed using lysergic acid methylpropylamide as the internal standard. The response of the MS was linear for concentrations ranging from 0.02 ng/mL (detection threshold) to 10.0 ng/mL. Several parameters such as the choice of the capillary column, the choice of the internal standard and that of the ionization mode (positive CI vs. EI) were rationalized. Decomposition pathways under both ionization modes were studied. Within-day and between-day stability were evaluated.

  7. A Protein Preparation Method for the High-throughput Identification of Proteins Interacting with a Nuclear Cofactor Using LC-MS/MS Analysis.

    PubMed

    Tsuchiya, Megumi; Karim, M Rezaul; Matsumoto, Taro; Ogawa, Hidesato; Taniguchi, Hiroaki

    2017-01-24

    Transcriptional coregulators are vital to the efficient transcriptional regulation of nuclear chromatin structure. Coregulators play a variety of roles in regulating transcription. These include the direct interaction with transcription factors, the covalent modification of histones and other proteins, and the occasional chromatin conformation alteration. Accordingly, establishing relatively quick methods for identifying proteins that interact within this network is crucial to enhancing our understanding of the underlying regulatory mechanisms. LC-MS/MS-mediated protein binding partner identification is a validated technique used to analyze protein-protein interactions. By immunoprecipitating a previously-identified member of a protein complex with an antibody (occasionally with an antibody for a tagged protein), it is possible to identify its unknown protein interactions via mass spectrometry analysis. Here, we present a method of protein preparation for the LC-MS/MS-mediated high-throughput identification of protein interactions involving nuclear cofactors and their binding partners. This method allows for a better understanding of the transcriptional regulatory mechanisms of the targeted nuclear factors.

  8. Bayesian Normalization Model for Label-Free Quantitative Analysis by LC-MS

    PubMed Central

    Nezami Ranjbar, Mohammad R.; Tadesse, Mahlet G.; Wang, Yue; Ressom, Habtom W.

    2016-01-01

    We introduce a new method for normalization of data acquired by liquid chromatography coupled with mass spectrometry (LC-MS) in label-free differential expression analysis. Normalization of LC-MS data is desired prior to subsequent statistical analysis to adjust variabilities in ion intensities that are not caused by biological differences but experimental bias. There are different sources of bias including variabilities during sample collection and sample storage, poor experimental design, noise, etc. In addition, instrument variability in experiments involving a large number of LC-MS runs leads to a significant drift in intensity measurements. Although various methods have been proposed for normalization of LC-MS data, there is no universally applicable approach. In this paper, we propose a Bayesian normalization model (BNM) that utilizes scan-level information from LC-MS data. Specifically, the proposed method uses peak shapes to model the scan-level data acquired from extracted ion chromatograms (EIC) with parameters considered as a linear mixed effects model. We extended the model into BNM with drift (BNMD) to compensate for the variability in intensity measurements due to long LC-MS runs. We evaluated the performance of our method using synthetic and experimental data. In comparison with several existing methods, the proposed BNM and BNMD yielded significant improvement. PMID:26357332

  9. Fingerprint of Hedyotis diffusa Willd. by HPLC-MS.

    PubMed

    Yang, Ting; Yang, Yi-Hua; Yang, Ju-Yun; Chen, Ben-Mei; Duan, Ju-Ping; Yu, Shu-Yi; Ouyang, Hong-Tao; Cheng, Jun-Ping; Chen, Yu-Xiang

    2008-01-01

    A HPLC-MS fingerprint method has been developed based on the consistent chromatographic features of the major chemical constituents among 10 batches of Hedyotis diffusa Willd. Chromatographic separation was conducted on a Hypersil-Keystone Hypurity C(18) column using methanol:water:acetic acid as the mobile phase. Major compounds, including oleanolic acid, ursolic acid and ferulic acid, were analysed by HPLC-MS. Their analysis was ascertained by comparison with data derived from the standard compounds. The HPLC-MS fingerprint was successfully applied to analyse and differentiate samples from different geographical origins, or processing methods. H. diffusa was well distinguished from Hedyotis chrysotricha by HPLC-MS. Therefore the establishment of fingerprint of H. diffusa is critical in assessing and controlling its overall quality.

  10. Effect of chlorination by-products on the quantitation of microcystins in finished drinking water.

    PubMed

    Rosenblum, Laura; Zaffiro, Alan; Adams, William A; Wendelken, Steven C

    2017-11-01

    Microcystins are toxic peptides that can be produced by cyanobacteria in harmful algal blooms (HABs). Various analytical techniques have been developed to quantify microcystins in drinking water, including liquid chromatography tandem mass spectrometry (LC/MS/MS), enzyme linked immunosorbent assay (ELISA), and oxidative cleavage to produce 2-methyl-3-methoxy-4-phenylbutyric acid (MMPB) with detection by LC/MS/MS, the "MMPB method". Both the ELISA and MMPB methods quantify microcystins by detecting a portion of the molecule common to most microcystins. However, there is little research evaluating the effect of microcystin chlorination by-products potentially produced during drinking water treatment on analytical results. To evaluate this potential, chlorinated drinking water samples were fortified with various microcystin congeners in bench-scale studies. The samples were allowed to react, followed by a comparison of microcystin concentrations measured using the three methods. The congener-specific LC/MS/MS method selectively quantified microcystins and was not affected by the presence of chlorination by-products. The ELISA results were similar to those obtained by LC/MS/MS for most microcystin congeners, but results deviated for a particular microcystin containing a variable amino acid susceptible to oxidation. The concentrations measured by the MMPB method were at least five-fold higher than the concentrations of microcystin measured by the other methods and demonstrate that detection of MMPB does not necessarily correlate to intact microcystin toxins in finished drinking water. Published by Elsevier Ltd.

  11. A rapid method for the simultaneous quantification of the major tocopherols, carotenoids, free and esterified sterols in canola (Brassica napus) oil using normal phase liquid chromatography.

    PubMed

    Flakelar, Clare L; Prenzler, Paul D; Luckett, David J; Howitt, Julia A; Doran, Gregory

    2017-01-01

    A normal phase high performance liquid chromatography (HPLC) method was developed to simultaneously quantify several prominent bioactive compounds in canola oil vis. α-tocopherol, γ-tocopherol, δ-tocopherol, β-carotene, lutein, β-sitosterol, campesterol and brassicasterol. The use of sequential diode array detection (DAD) and tandem mass spectrometry (MS/MS) allowed direct injection of oils, diluted in hexane without derivatisation or saponification, greatly reducing sample preparation time, and permitting the quantification of both free sterols and intact sterol esters. Further advantages over existing methods included increased analytical selectivity, and a chromatographic run time substantially less than other reported normal phase methods. The HPLC-DAD-MS/MS method was applied to freshly extracted canola oil samples as well as commercially available canola, palm fruit, sunflower and olive oils. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Determination of nucleoside analog mono-, di-, and tri-phosphates in cellular matrix by solid phase extraction and ultra-sensitive LC-MS/MS detection.

    PubMed

    Bushman, Lane R; Kiser, Jennifer J; Rower, Joseph E; Klein, Brandon; Zheng, Jia-Hua; Ray, Michelle L; Anderson, Peter L

    2011-09-10

    An ultra-sensitive liquid chromatography tandem mass spectrometry (LC-MS/MS) assay was developed and validated to facilitate the assessment of clinical pharmacokinetics of nucleotide analogs from lysed intracellular matrix. The method utilized a strong anion exchange isolation of mono-(MP), di-(DP), and tri-phosphates (TP) from intracellular matrix. Each fraction was then dephosphorylated to the parent moiety yielding a molar equivalent to the original nucleotide analog intracellular concentration. The analytical portion of the methodology was optimized in specific nucleoside analog centric modes (i.e. tenofovir (TFV) centric, zidovudine (ZDV) centric), which included desalting/concentration by solid phase extraction and detection by LC-MS/MS. Nucleotide analog MP-, DP-, and TP-determined on the TFV centric mode of analysis include TFV, lamivudine (3TC), and emtricitibine (FTC). The quantifiable linear range for TFV was 2.5-2000 fmol/sample, and that for 3TC/FTC was 0.1 200 pmol/sample. Nucleoside analog MP-, DP-, and TP-determined on the ZDV centric mode of analysis included 3TC and ZDV. The quantifiable linear range for 3TC was 0.1 100 pmol/sample, and 5-2000 fmol/sample for ZDV. Stable labeled isotopic internal standards facilitated accuracy and precision in alternative cell matrices, which supported the intended use of the method for MP, DP, and TP determinations in various cell types. The method was successfully applied to clinical research samples generating novel intracellular information for TFV, FTC, ZDV, and 3TC nucleotides. This document outlines method development, validation, and application to clinical research. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. High-throughput SISCAPA quantitation of peptides from human plasma digests by ultrafast, liquid chromatography-free mass spectrometry.

    PubMed

    Razavi, Morteza; Frick, Lauren E; LaMarr, William A; Pope, Matthew E; Miller, Christine A; Anderson, N Leigh; Pearson, Terry W

    2012-12-07

    We investigated the utility of an SPE-MS/MS platform in combination with a modified SISCAPA workflow for chromatography-free MRM analysis of proteotypic peptides in digested human plasma. This combination of SISCAPA and SPE-MS/MS technology allows sensitive, MRM-based quantification of peptides from plasma digests with a sample cycle time of ∼7 s, a 300-fold improvement over typical MRM analyses with analysis times of 30-40 min that use liquid chromatography upstream of MS. The optimized system includes capture and enrichment to near purity of target proteotypic peptides using rigorously selected, high affinity, antipeptide monoclonal antibodies and reduction of background peptides using a novel treatment of magnetic bead immunoadsorbents. Using this method, we have successfully quantitated LPS-binding protein and mesothelin (concentrations of ∼5000 ng/mL and ∼10 ng/mL, respectively) in human plasma. The method eliminates the need for upstream liquid-chromatography and can be multiplexed, thus facilitating quantitative analysis of proteins, including biomarkers, in large sample sets. The method is ideal for high-throughput biomarker validation after affinity enrichment and has the potential for applications in clinical laboratories.

  14. NHEXAS PHASE I ARIZONA STUDY--STANDARD OPERATING PROCEDURE FOR ANALYSIS OF PESTICIDE SAMPLES BY GC/MS (BCO-L-15.1)

    EPA Science Inventory

    The purpose of this SOP is to describe the methods used for detection and quantification by gas chromatography/mass spectrometry (GC/MS) of pesticides in a variety of matrices, including air, house dust, soil, and handwipes. This analysis involves automated gas GC/MS analysis us...

  15. UPLC-MS/MS determination of ptaquiloside and pterosin B in preserved natural water.

    PubMed

    Clauson-Kaas, Frederik; Hansen, Hans Christian Bruun; Strobel, Bjarne W

    2016-11-01

    The naturally occurring carcinogen ptaquiloside and its degradation product pterosin B are found in water leaching from bracken stands. The objective of this work is to present a new sample preservation method and a fast UPLC-MS/MS method for quantification of ptaquiloside and pterosin B in environmental water samples, employing a novel internal standard. A faster, reliable, and efficient method was developed for isolation of high purity ptaquiloside and pterosin B from plant material for use as analytical standards, with purity verified by 1 H-NMR. The chemical analysis was performed by cleanup and preconcentration of samples with solid phase extraction, before analyte quantification with UPLC-MS/MS. By including gradient elution and optimizing the liquid chromatography mobile phase buffer system, a total run cycle of 5 min was achieved, with method detection limits, including preconcentration, of 8 and 4 ng/L for ptaquiloside and pterosin B, respectively. The use of loganin as internal standard improved repeatability of the determination of both analytes, though it could not be employed for sample preparation. Buffering raw water samples in situ with ammonium acetate to pH ∼5.5 decisively increased sample integrity at realistic transportation and storing conditions prior to extraction. Groundwater samples collected in November 2015 at the shallow water table below a Danish bracken stand were preserved and analyzed using the above methods, and PTA concentrations of 3.8 ± 0.24 μg/L (±sd, n = 3) were found, much higher than previously reported. Graphical abstract Workflow overview of ptaquiloside determination.

  16. [Fast identification of constituents of Lagotis brevituba by using UPLC-Q-TOF-MS/MS method].

    PubMed

    Xie, Jing; Zhang, Li; Zeng, Jin-Xiang; Li, Min; Wang, Juan; Xie, Xiong-Xiong; Zhong, Guo-Yue; Luo, Guang-Ming; Yuan, Jin-Bin; Liang, Jian

    2017-06-01

    The chemical constituents of Lagotis brevituba were rapidly determined and analyzed by using ultra performance liquid chromatography tandem quadrupole time of flight mass spectrometry (UPLC-Q-TOF-MS/MS) method, providing material basis for the clinical application of L. brevituba. The separation was performed on UPLC YMC-Triart C₁₈ (2.1 mm×100 mm, 1.9 μm) column, with acetonitrile-water containing 0.2% formic acid as mobile phase for gradient elution. The flow rate was 0.4 mL•min-1 gradient elution and column temperature was 40 ℃, the injection volume was 2 μL. ESI ion source was used to ensure the data collected in a negative ion mode. The chemical components of L. brevituba were identified through retention time, exact relative molecular mass, cleavage fragments of MS/MS and reported data. The results showed that a total of 22 compounds were identified, including 11 flavones, 6 phenylethanoid glycosides, 1 iridoid glucosides, and 4 organic acid. The UPLC-Q-TOF-MS/MS method could fast identify the chemical components of L. brevituba, providing valuable information about L. brevituba for its clinical application. Copyright© by the Chinese Pharmaceutical Association.

  17. Recent advances in combination of capillary electrophoresis with mass spectrometry: methodology and theory.

    PubMed

    Klepárník, Karel

    2015-01-01

    This review focuses on the latest development of microseparation electromigration methods in capillaries and microfluidic devices with MS detection and identification. A wide selection of 183 relevant articles covers the literature published from June 2012 till May 2014 as a continuation of the review article on the same topic by Kleparnik [Electrophoresis 2013, 34, 70-86]. Special attention is paid to the new improvements in the theory of instrumentation and methodology of MS interfacing with capillary versions of zone electrophoresis, ITP, and IEF. Ionization methods in MS include ESI, MALDI, and ICP. Although the main attention is paid to the development of instrumentation and methodology, representative examples illustrate also applications in the proteomics, glycomics, metabolomics, biomarker research, forensics, pharmacology, food analysis, and single-cell analysis. The combinations of MS with capillary versions of electrochromatography and micellar electrokinetic chromatography are not included. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Evaluation of VITEK mass spectrometry (MS), a matrix-assisted laser desorption ionization time-of-flight MS system for identification of anaerobic bacteria.

    PubMed

    Lee, Wonmok; Kim, Myungsook; Yong, Dongeun; Jeong, Seok Hoon; Lee, Kyungwon; Chong, Yunsop

    2015-01-01

    By conventional methods, the identification of anaerobic bacteria is more time consuming and requires more expertise than the identification of aerobic bacteria. Although the matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) systems are relatively less studied, they have been reported to be a promising method for the identification of anaerobes. We evaluated the performance of the VITEK MS in vitro diagnostic (IVD; 1.1 database; bioMérieux, France) in the identification of anaerobes. We used 274 anaerobic bacteria isolated from various clinical specimens. The results for the identification of the bacteria by VITEK MS were compared to those obtained by phenotypic methods and 16S rRNA gene sequencing. Among the 249 isolates included in the IVD database, the VITEK MS correctly identified 209 (83.9%) isolates to the species level and an additional 18 (7.2%) at the genus level. In particular, the VITEK MS correctly identified clinically relevant and frequently isolated anaerobic bacteria to the species level. The remaining 22 isolates (8.8%) were either not identified or misidentified. The VITEK MS could not identify the 25 isolates absent from the IVD database to the species level. The VITEK MS showed reliable identifications for clinically relevant anaerobic bacteria.

  19. Evaluating Barriers to Adherence to Dietary Recommendations in Iranian Adults with Metabolic Syndrome: A Qualitative Study Using the Theory of Reasoned Action

    PubMed Central

    ESMAEILI, Naseh; ALIZADEH, Mohammad; TARIGHAT ESFANJANI, Ali; KHEIROURI, Sorayya

    2016-01-01

    Background: Metabolic syndrome (MS) is defined as a pattern of metabolic disorders including central obesity, insulin resistance or hyperglycemia, high blood pressure, and dyslipidemia. Many studies show a clear relationship between diet and components of MS. The aim of the current study was to identify barriers to adherence to dietary recommendations among Iranian MS patients. Methods: The theory of reasoned action (TRA) served as the framework for this qualitative study. Data collection was conducted through six semi-structured focus group discussions, from Apr to Jun 2013. Subjects included 36 married men and women with different levels of education between the ages of 20–50 with MS diagnosed based on IDF’s (International Diabetes federation) criteria. All focus group discussions were audio recorded and transcribed. The thematic content analysis method was used to analyze the study data. Results: This study identified the most important barriers to adherence to dietary recommendations. MS patients have problems in their attitude toward MS components and their relationship to nutrition. They also had wrong attitudes toward fats and oils, salt, dairy products, cereals, and sugary drinks and sweets. Subjective norms that affects patient eating identifies too. Conclusion: We identified barriers to adherence to dietary recommendations in MS patients that could be used to prevent MS consequences and provide patients with nutrition education. PMID:27517000

  20. Employment among Working-Age Adults with Multiple Sclerosis: A Data-Mining Approach to Identifying Employment Interventions

    ERIC Educational Resources Information Center

    Bishop, Malachy; Chan, Fong; Rumrill, Phillip D., Jr.; Frain, Michael P.; Tansey, Timothy N.; Chiu, Chung-Yi; Strauser, David; Umeasiegbu, Veronica I.

    2015-01-01

    Purpose: To examine demographic, functional, and clinical multiple sclerosis (MS) variables affecting employment status in a national sample of adults with MS in the United States. Method: The sample included 4,142 working-age (20-65 years) Americans with MS (79.1% female) who participated in a national survey. The mean age of participants was…

  1. Quantitative Determination of Fluorinated Caffeic Acid Phenethyl Ester Derivative From Rat Blood Plasma by Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry

    DTIC Science & Technology

    2008-03-06

    Caffeic acid phenethyl ester (CAPE), a plant-derived polyphenolic compound (Fig. 1), is a component of bee propolis . Propolis has been used as a folk...analytical methods have been documented. These include an HPLC-UV determination of CAPE from a propolis -containing gel [13], HPLC-ESI-MS measurement...of CAPE from crude propolis [14], and HPLC- ESI-MS/MS analysis of CAPE in biological samples [15]. In this paper, we developed a method using ultra

  2. Selective and comprehensive analysis of organohalogen compounds by GC × GC-HRTofMS and MS/MS.

    PubMed

    Hashimoto, Shunji; Zushi, Yasuyuki; Takazawa, Yoshikatsu; Ieda, Teruyo; Fushimi, Akihiro; Tanabe, Kiyoshi; Shibata, Yasuyuki

    2018-03-01

    Thousands of organohalogen compounds, including hazardous chemicals such as polychlorinated biphenyls (PCBs) and other persistent organic pollutants (POPs), were selectively and simultaneously detected and identified with simple, or no, purification from environmental sample extracts by using several advanced methods. The methods used were software extraction from two-dimensional gas chromatography-high-resolution time-of-flight mass spectrometry (GC × GC-HRTofMS) data, measurement by negative chemical ionization with HRTofMS, and neutral loss scanning (NLS) with GC × GC-MS/MS. Global and selective detection of organochlorines and bromines in environmental samples such as sediments and fly ash was achieved by NLS using GC × GC-MS/MS (QQQ), with the expected losses of 35 Cl and 79 Br. We confirmed that negative chemical ionization was effective for sensitive and selective ionization of organohalogens, even using GC × GC-HRTofMS. The 2D total ion chromatograms obtained by using negative chemical ionization and selective extraction of organohalogens using original software from data measured by electron impact ionization were very similar; the software thus functioned well to extract organohalogens. Combining measurements made by using these different methods will help to detect organohalogens selectively and globally. However, to compare the data obtained by individual measurements, the retention times of the peaks on the 2D chromatograms need to match.

  3. Study on Chemical Constituents in Polygoni Cuspidati Folium and its Preparation by UPLC-ESI-Q-TOF-MS/MS.

    PubMed

    Wang, Xin; Qin, Yao; Li, Guang-Quan; Chen, Shuai; Ma, Jing-Qi; Guo, Yan-Lei; Luo, Wei-Zao

    2018-03-15

    A rapid and credible analytical method was developed using online UPLC-ESI-Q-TOF-MS/MS to identify chemical constituents in Polygoni cuspidati folium and its preparation. By accurate mass measurements within 6.5 ppm error for [M-H]- ion in routine analysis, 26 chemical constituents, including tannin, derivatives of phenylpropionic acid, stilbene, flavonoid, anthraquinone, torachryson and its derivatives, were identified or tentatively characterized. Among them, five constituents (compounds 19-23) were firstly reported in Polygoni cuspidati folium, other 17 constituents were coexisting in both Polygoni cuspidati folium and its preparation. Fragmentation behaviors of different categories of constituents were also investigated to confirm the results. This established UPLC-ESI-Q-TOF-MS/MS method, with reliance and efficiency for the identification the major constituents, would be the basis for quality control of Polygoni cuspidati folium and its preparation.

  4. Analysis of Glycosaminoglycans Using Mass Spectrometry

    PubMed Central

    Staples, Gregory O.; Zaia, Joseph

    2015-01-01

    The glycosaminoglycans (GAGs) are linear polysaccharides expressed on animal cell surfaces and in extracellular matrices. Their biosynthesis is under complex control and confers a domain structure that is essential to their ability to bind to protein partners. Key to understanding the functions of GAGs are methods to determine accurately and rapidly patterns of sulfation, acetylation and uronic acid epimerization that correlate with protein binding or other biological activities. Mass spectrometry (MS) is particularly suitable for the analysis of GAGs for biomedical purposes. Using modern ionization techniques it is possible to accurately determine molecular weights of GAG oligosaccharides and their distributions within a mixture. Methods for direct interfacing with liquid chromatography have been developed to permit online mass spectrometric analysis of GAGs. New tandem mass spectrometric methods for fine structure determination of GAGs are emerging. This review summarizes MS-based approaches for analysis of GAGs, including tissue extraction and chromatographic methods compatible with LC/MS and tandem MS. PMID:25705143

  5. Simultaneous Analysis of Iridoid Glycosides and Anthraquinones in Morinda officinalis Using UPLC-QqQ-MS/MS and UPLC-Q/TOF-MSE.

    PubMed

    Zhao, Xiangsheng; Wei, Jianhe; Yang, Meihua

    2018-05-03

    Morinda officinalis is an important herbal medicine and functional food, and its main constituents include anthraquinone and iridoid glycosides. Quantification of the main compounds is a necessary step to understand the quality and therapeutic properties of M. officinalis , but this has not yet been performed based on liquid chromatography/tandem mass spectrometry (LC-MS/MS). Analytes were extracted from M. officinalis by reflux method. Ultrahigh-performance liquid chromatography coupled with a triple quadrupole mass spectrometry (UPLC-QqQ-MS) using multiple reaction monitoring (MRM) mode was applied for quantification. Fragmentation pathways of deacetyl asperulosidic acid and rubiadin were investigated based on UPLC with quadrupole time-of-flight tandem mass spectrometry (Q/TOF-MS) in the MS E centroid mode. The method showed a good linearity over a wide concentration range (R² ≥ 0.9930). The limits of quantification of six compounds ranged from 2.6 to 27.57 ng/mL. The intra- and inter-day precisions of the investigated components exhibited an RSD within 4.5% with mean recovery rates of 95.32⁻99.86%. Contents of selected compounds in M. officinalis varied significantly depending on region. The fragmentation pathway of deacetyl asperulosidic and rubiadin was proposed. A selective and sensitive method was developed for determining six target compounds in M. officinalis by UPLC-MS/MS. Furthermore, the proposed method will be helpful for quality control and identification main compounds of M. officinalis .

  6. Chromatography/Mass Spectrometry-Based Biomarkers in the Field of Obstructive Sleep Apnea

    PubMed Central

    Xu, Huajun; Zheng, Xiaojiao; Jia, Wei; Yin, Shankai

    2015-01-01

    Abstract Biomarker assessment is based on quantifying several proteins and metabolites. Recent developments in proteomics and metabolomics have enabled detection of these small molecules in biological samples and exploration of the underlying disease mechanisms in obstructive sleep apnea (OSA). This systemic review was performed to identify biomarkers, which were only detected by chromatography and/or mass spectrometry (MS) and to discuss the role of these biomarkers in the field of OSA. We systemically reviewed relevant articles from PubMed and EMBASE referring to proteins and metabolite profiles of biological samples in patients with OSA. The analytical platforms in this review were focused on chromatography and/or MS. In total, 30 studies evaluating biomarkers in patients with OSA using chromatography and/or MS methods were included. Numerous proteins and metabolites, including lipid profiles, adrenergic/dopaminergic biomarkers and derivatives, amino acids, oxidative stress biomarkers, and other micromolecules were identified in patients with OSA. Applying chromatography and/or MS methods to detect biomarkers helps develop an understanding of OSA mechanisms. More proteomic and metabolomic studies are warranted to develop potential diagnostic and clinical monitoring methods for OSA. PMID:26448002

  7. Detection of Stimulants and Narcotics by Liquid Chromatography-Tandem Mass Spectrometry and Gas Chromatography-Mass Spectrometry for Sports Doping Control.

    PubMed

    Ahrens, Brian D; Kucherova, Yulia; Butch, Anthony W

    2016-01-01

    Sports drug testing laboratories are required to detect several classes of compounds that are prohibited at all times, which include anabolic agents, peptide hormones, growth factors, beta-2 agonists, hormones and metabolic modulators, and diuretics/masking agents. Other classes of compounds such as stimulants, narcotics, cannabinoids, and glucocorticoids are also prohibited, but only when an athlete is in competition. A single class of compounds can contain a large number of prohibited substances and all of the compounds should be detected by the testing procedure. Since there are almost 70 stimulants on the prohibited list it can be a challenge to develop a single screening method that will optimally detect all the compounds. We describe a combined liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-mass spectrometry (GC-MS) testing method for detection of all the stimulants and narcotics on the World Anti-Doping Agency prohibited list. Urine for LC-MS/MS testing does not require sample pretreatment and is a direct dilute and shoot method. Urine samples for the GC-MS method require a liquid-liquid extraction followed by derivatization with trifluoroacetic anhydride.

  8. [Rapid determination of illicit beta2-agonist additives in health foods and traditional Chinese patent medicines with DCBI-MS/MS method].

    PubMed

    Hou, Yu-Lan; Wu, Shuang; Wang, Hua; Zhao, Yong; Liao, Peng; Tian, Qing-Qing; Sun, Wen-Jian; Chen, Bo

    2013-01-01

    A novel rapid method for detection of the illicit beta2-agonist additives in health foods and traditional Chinese patent medicines was developed with the desorption corona beam ionization mass spectrometry (DCBI-MS) technique. The DCBI conditions including temperature and sample volume were optimized according to the resulting mass spectra intensity. Matrix effect on 9 beta2-agonists additives was not significant in the proposed rapid determination procedure. All of the 9 target molecules were detected within 1 min. Quantification was achieved based on the typical fragment ion in MS2 spectra of each analyte. The method showed good linear coefficients in the range of 1-100 mg x L(-1) for all analytes. The relative deviation values were between 14.29% and 25.13%. Ten claimed antitussive and antiasthmatic health foods and traditional Chinese patent medicines from local pharmacies were analyzed. All of them were negative with the proposed DCBI-MS method. Without tedious sample pretreatments, the developed DCBI-MS is simple, rapid and sensitive for rapid qualification and semi-quantification of the illicit beta2-agonist additives in health foods and traditional Chinese patent medicines.

  9. Direct Surface and Droplet Microsampling for Electrospray Ionization Mass Spectrometry Analysis with an Integrated Dual-Probe Microfluidic Chip

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Cong-Min; Zhu, Ying; Jin, Di-Qiong

    Ambient mass spectrometry (MS) has revolutionized the way of MS analysis and broadened its application in various fields. This paper describes the use of microfluidic techniques to simplify the setup and improve the functions of ambient MS by integrating the sampling probe, electrospray emitter probe, and online mixer on a single glass microchip. Two types of sampling probes, including a parallel-channel probe and a U-shaped channel probe, were designed for dryspot and liquid-phase droplet samples, respectively. We demonstrated that the microfabrication techniques not only enhanced the capability of ambient MS methods in analysis of dry-spot samples on various surfaces, butmore » also enabled new applications in the analysis of nanoliter-scale chemical reactions in an array of droplets. The versatility of the microchip-based ambient MS method was demonstrated in multiple different applications including evaluation of residual pesticide on fruit surfaces, sensitive analysis of low-ionizable analytes using postsampling derivatization, and high-throughput screening of Ugi-type multicomponent reactions.« less

  10. Use of a deuterated internal standard with pyrolysis-GC/MS dimeric marker analysis to quantify tire tread particles in the environment.

    PubMed

    Unice, Kenneth M; Kreider, Marisa L; Panko, Julie M

    2012-11-08

    Pyrolysis(pyr)-GC/MS analysis of characteristic thermal decomposition fragments has been previously used for qualitative fingerprinting of organic sources in environmental samples. A quantitative pyr-GC/MS method based on characteristic tire polymer pyrolysis products was developed for tread particle quantification in environmental matrices including soil, sediment, and air. The feasibility of quantitative pyr-GC/MS analysis of tread was confirmed in a method evaluation study using artificial soil spiked with known amounts of cryogenically generated tread. Tread concentration determined by blinded analyses was highly correlated (r2 ≥ 0.88) with the known tread spike concentration. Two critical refinements to the initial pyrolysis protocol were identified including use of an internal standard and quantification by the dimeric markers vinylcyclohexene and dipentene, which have good specificity for rubber polymer with no other appreciable environmental sources. A novel use of deuterated internal standards of similar polymeric structure was developed to correct the variable analyte recovery caused by sample size, matrix effects, and ion source variability. The resultant quantitative pyr-GC/MS protocol is reliable and transferable between laboratories.

  11. A Simple and Rapid HPLC-PDA MS Method for the Profiling of Citrus Peels and Traditional Italian Liquors.

    PubMed

    Guccione, Clizia; Bergonzi, Maria Camilla; Piazzini, Vieri; Bilia, Anna Rita

    2016-07-01

    A chromatographic method for the qualitative and quantitative characterization of peels and preparations based on different species of Citrus was developed in order to obtain a complete profile of the constituents, including flavonoids and protoalkaloids. Commercial peels of sweet orange, lemon, mandarin, and grapefruit were analyzed. Seventeen constituents including flavanones, flavones, polymethoxyflavones, and protoalkaloids were identified by HPLC-PDA, HPLC-MS, and HPLC-MS/MS using a comparison of retention times and UV-Vis and MS spectra with reference standards and literature data. The total amount of flavanones [neoeriocitrin (5), naringin (8) and hesperidin (9)] and polymethoxflavones [sinensetin (12), nobiletin (14), 3,5,6,7,8,3',4'-heptamethoxyflavone (15), and tangeretin (16)] was determined and expressed as naringin (8) or hesperidin (9), and sinensetin (12), respectively. The protoalkaloid synephrine was detected in all samples, except in grapefruit, but its content was lower than the limit of quantification. Qualitative and quantitative chemical profiles of three different Italian aromatic liquors ("Limoncello", "Arancello", and "Mandarinetto"), prepared according to traditional recipes, were also analyzed. Georg Thieme Verlag KG Stuttgart · New York.

  12. Development of a general method for quantifying IgG-based therapeutic monoclonal antibodies in human plasma using protein G purification coupled with a two internal standard calibration strategy using LC-MS/MS.

    PubMed

    Chiu, Huai-Hsuan; Liao, Hsiao-Wei; Shao, Yu-Yun; Lu, Yen-Shen; Lin, Ching-Hung; Tsai, I-Lin; Kuo, Ching-Hua

    2018-08-17

    Monoclonal antibody (mAb) drugs have generated much interest in recent years for treating various diseases. Immunoglobulin G (IgG) represents a high percentage of mAb drugs that have been approved by the Food and Drug Administration (FDA). To facilitate therapeutic drug monitoring and pharmacokinetic/pharmacodynamic studies, we developed a general liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to quantify the concentration of IgG-based mAbs in human plasma. Three IgG-based drugs (bevacizumab, nivolumab and pembrolizumab) were selected to demonstrate our method. Protein G beads were used for sample pretreatment due to their universal ability to trap IgG-based drugs. Surrogate peptides that were obtained after trypsin digestion were quantified by using LC-MS/MS. To calibrate sample preparation errors and matrix effects that occur during LC-MS/MS analysis, we used two internal standards (IS) method that include the IgG-based drug-IS tocilizumab and post-column infused IS. Using two internal standards was found to effectively improve quantification accuracy, which was within 15% for all mAb drugs that were tested at three different concentrations. This general method was validated in term of its precision, accuracy, linearity and sensitivity for 3 demonstration mAb drugs. The successful application of the method to clinical samples demonstrated its' applicability in clinical analysis. It is anticipated that this general method could be applied to other mAb-based drugs for use in precision medicine and clinical studies. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Development and Validation of a Simple and Rapid UPLC-MS Assay for Valproic Acid and Its Comparison With Immunoassay and HPLC Methods.

    PubMed

    Zhao, Mingming; Li, Guofei; Qiu, Feng; Sun, Yaxin; Xu, Yinghong; Zhao, Limei

    2016-04-01

    Valproic acid (VPA), a widely used antiepileptic drug, has a narrow therapeutic range of 50-100 mcg/mL and shows large individual variability. It is very important to monitor the trough concentration of VPA using a reliable method. Therefore, the aim of this study was to develop and validate a rapid ultraperformance liquid chromatographic-mass spectrometry (UPLC-MS) method for quantification of VPA in human serum and to compare with fluorescence polarization immunoassay (FPIA), chemiluminescence microparticle immunoassay (CMIA), and high-performance liquid chromatography (HPLC) methods. The method included extraction of VPA in serum by deproteinization with acetonitrile. The analysis was performed using an EC-C18 column (2.7 μm, 4.6 × 50 mm) under isocratic conditions with a mobile phase of acetonitrile/water (containing 0.1% formic acid) (45/55, vol/vol) at a flow rate of 0.6 mL/min. The detection was performed on a triple-quadrupole tandem mass spectrometer using an electrospary probe in the negative ionization mode. The method was validated by studies of selectivity, linearity, lower limit of quantification, accuracy, precision, recovery, matrix effect, and stability. Furthermore, all the 4 methods including FPIA, CMIA, and HPLC were subsequently used to assay the VPA concentration in 498 clinical serum samples collected from patients who received VPA. These methods were compared by Deming regression and Bland-Altman analysis. The retention time of VPA was 2.09 minutes. The calibration curve was linear over the concentration range of 1-200 mcg/mL, with a lower limit of quantification of 1 mcg/mL. The interday and intraday precision (RSD %) was less than 4.6% and 4.5%, respectively, and the accuracy (RE %) was below 7.9%. The recoveries and matrix effect of VPA at concentrations of 2, 50, and 160 mcg/mL met the requirement for the analysis of biological samples. No obvious degradation of VPA was observed under various storage conditions including room temperature for 12 hour, 3 freeze-thaw cycles, and -20°C for 3 months. Regression analysis showed that the correlation coefficients for the UPLC-MS versus FPIA, CMIA, and HPLC were 0.989, 0.988, and 0.987, respectively. The results of agreement tests between UPLC-MS and other methods showed that the mean difference of UPLC-MS and FPIA was -1.4 mcg/mL and 95% confidence interval of -7.7 to 4.9 mcg/mL, and the values for UPLC-MS and CMIA were -0.8 mcg/mL and -7.5 to 5.8 mcg/mL, for UPLC-MS and HPLC were 1.1 mcg/mL and -5.7 to 7.9 mcg/mL. The rapid UPLC-MS method we developed showed a good analytical performance required for therapeutic drug monitoring, leading to potential improvements in patient care and laboratory management. Compared with the FPIA, CMIA, and HPLC methods, the UPLC-MS method correlated well and displayed comparable VPA concentrations.

  14. A sensitive multi-residue method for the determination of 35 micropollutants including pharmaceuticals, iodinated contrast media and pesticides in water.

    PubMed

    Valls-Cantenys, Carme; Scheurer, Marco; Iglesias, Mònica; Sacher, Frank; Brauch, Heinz-Jürgen; Salvadó, Victoria

    2016-09-01

    A sensitive, multi-residue method using solid-phase extraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed to determine a representative group of 35 analytes, including corrosion inhibitors, pesticides and pharmaceuticals such as analgesic and anti-inflammatory drugs, five iodinated contrast media, β-blockers and some of their metabolites and transformation products in water samples. Few other methods are capable of determining such a broad range of contrast media together with other analytes. We studied the parameters affecting the extraction of the target analytes, including sorbent selection and extraction conditions, their chromatographic separation (mobile phase composition and column) and detection conditions using two ionisation sources: electrospray ionisation (ESI) and atmospheric pressure chemical ionisation (APCI). In order to correct matrix effects, a total of 20 surrogate/internal standards were used. ESI was found to have better sensitivity than APCI. Recoveries ranging from 79 to 134 % for tap water and 66 to 144 % for surface water were obtained. Intra-day precision, calculated as relative standard deviation, was below 34 % for tap water and below 21 % for surface water, groundwater and effluent wastewater. Method quantification limits (MQL) were in the low ng L(-1) range, except for the contrast agents iomeprol, amidotrizoic acid and iohexol (22, 25.5 and 17.9 ng L(-1), respectively). Finally, the method was applied to the analysis of 56 real water samples as part of the validation procedure. All of the compounds were detected in at least some of the water samples analysed. Graphical Abstract Multi-residue method for the determination of micropollutants including pharmaceuticals, iodinated contrast media and pesticides in waters by LC-MS/MS.

  15. Standard addition method for the determination of pharmaceutical residues in drinking water by SPE-LC-MS/MS.

    PubMed

    Cimetiere, Nicolas; Soutrel, Isabelle; Lemasle, Marguerite; Laplanche, Alain; Crocq, André

    2013-01-01

    The study of the occurrence and fate of pharmaceutical compounds in drinking or waste water processes has become very popular in recent years. Liquid chromatography with tandem mass spectrometry is a powerful analytical tool often used to determine pharmaceutical residues at trace level in water. However, many steps may disrupt the analytical procedure and bias the results. A list of 27 environmentally relevant molecules, including various therapeutic classes and (cardiovascular, veterinary and human antibiotics, neuroleptics, non-steroidal anti-inflammatory drugs, hormones and other miscellaneous pharmaceutical compounds), was selected. In this work, a method was developed using ultra performance liquid chromatography coupled to tandem mass spectrometry (UPLC-MS/MS) and solid-phase extraction to determine the concentration of the 27 targeted pharmaceutical compounds at the nanogram per litre level. The matrix effect was evaluated from water sampled at different treatment stages. Conventional methods with external calibration and internal standard correction were compared with the standard addition method (SAM). An accurate determination of pharmaceutical compounds in drinking water was obtained by the SAM associated with UPLC-MS/MS. The developed method was used to evaluate the occurrence and fate of pharmaceutical compounds in some drinking water treatment plants in the west of France.

  16. Simultaneous analysis of aminoglycosides with many other classes of drug residues in bovine tissues by ultrahigh-performance liquid chromatography-tandem mass spectrometry using an ion-pairing reagent added to final extracts.

    PubMed

    Lehotay, Steven J; Lightfield, Alan R

    2018-01-01

    The way to maximize scope of analysis, sample throughput, and laboratory efficiency in the monitoring of veterinary drug residues in food animals is to determine as many analytes as possible as fast as possible in as few methods as possible. Capital and overhead expenses are also reduced by using fewer instruments in the overall monitoring scheme. Traditionally, the highly polar aminoglycoside antibiotics require different chromatographic conditions from other classes of drugs, but in this work, we demonstrate that an ion-pairing reagent (sodium 1-heptanesulfonate) added to the combined final extracts from two sample preparation methods attains good separation of 174 targeted drugs, including 9 aminoglycosides, in the same 10.5-min ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) analysis. The full method was validated in bovine kidney, liver, and muscle tissues according to US regulatory protocols, and 137-146 (79-84%) of the drugs gave between 70 and 120% average recoveries with ≤ 25% RSDs in the different types of tissues spiked at 0.5, 1, and 2 times the regulatory levels of interest (10-1000 ng/g depending on the drug). This method increases sample throughput and the possible number of drugs monitored in the US National Residue Program, and requires only one UHPLC-MS/MS method and instrument for analysis rather than two by the previous scheme. Graphical abstract Outline of the streamlined approach to monitor 174 veterinary drugs, including aminoglycosides, in bovine tissues by combining two extracts of the same sample with an ion-pairing reagent for analysis by UHPLC-MS/MS.

  17. [Metabolites and metabolic pathways of mesaconitine in rat liver microsomal investigated by using UPLC-MS/MS method in vitro].

    PubMed

    Bi, Yun-Feng; Liu, Shu; Zhang, Rui-Xing; Song, Feng-Rui; Liu, Zhi-Qiang

    2013-12-01

    Mesaconitine was incubated with rat liver microsomes in vitro. The metabolites of mesaconitine in rat liver microsomes were identified by ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method with high resolution power. A typical reaction mixture of 100 mol L-1 Tris-HCI buffer (pH 7.4) containing 0.5 gL-1 microsomal protein and 50 micro molL-1 mesaconitine was prepared. The above reaction mixture was divided into six groups, and the volume of each group was 200 micro L. The incubation mixture was pre-incubated at 37 degrees C for 2 min and the reactions were initiated by adding NADPH generating system. After 90 min incubation at 37 degrees C, 200 micro L of acetonitrile was added to each group to stop the reaction. The metabolites of mesaconitine were investigated by UPLC-MS/MS method. Mesaconitine and 6 metabolites M1-M6 were found in the incubation system. The structures were characterized according to the data from MS/MS spectra and literatures. The metabolic reactions of mesaconitine in rat liver microsomes included the demethylation, deacetylation, dehydrogenation and hydroxylation. The major metabolic pathways of mesaconitine in rat liver microsomes were determined by UPLC-MS/MS on multiple reaction monitoring (MRM) mode combined with specific inhibitors of cytochrome P450 (CYP) isoforms, including alpha-naphthoflavone (CYP1A2), quinine (CYP2D), diethyldithiocarbamate (CYP2E1), ketoconazole (CYP3A) and sulfaphenazole (CYP2C), separately. Mesaconitine was mainly metabolized by CYP3A. CYP2C and CYP2D were also more important CYP isoforms for the metabolism reactions of mesaconitine, but CYP1A2 and CYP2E1 haven't any contribution to MA metabolism in rat liver microsomes.

  18. Comprehensive automation of the solid phase extraction gas chromatographic mass spectrometric analysis (SPE-GC/MS) of opioids, cocaine, and metabolites from serum and other matrices.

    PubMed

    Lerch, Oliver; Temme, Oliver; Daldrup, Thomas

    2014-07-01

    The analysis of opioids, cocaine, and metabolites from blood serum is a routine task in forensic laboratories. Commonly, the employed methods include many manual or partly automated steps like protein precipitation, dilution, solid phase extraction, evaporation, and derivatization preceding a gas chromatography (GC)/mass spectrometry (MS) or liquid chromatography (LC)/MS analysis. In this study, a comprehensively automated method was developed from a validated, partly automated routine method. This was possible by replicating method parameters on the automated system. Only marginal optimization of parameters was necessary. The automation relying on an x-y-z robot after manual protein precipitation includes the solid phase extraction, evaporation of the eluate, derivatization (silylation with N-methyl-N-trimethylsilyltrifluoroacetamide, MSTFA), and injection into a GC/MS. A quantitative analysis of almost 170 authentic serum samples and more than 50 authentic samples of other matrices like urine, different tissues, and heart blood on cocaine, benzoylecgonine, methadone, morphine, codeine, 6-monoacetylmorphine, dihydrocodeine, and 7-aminoflunitrazepam was conducted with both methods proving that the analytical results are equivalent even near the limits of quantification (low ng/ml range). To our best knowledge, this application is the first one reported in the literature employing this sample preparation system.

  19. The content of secondary phenol metabolites in pruned leaves of Aloe arborescens, a comparison between two methods: leaf exudates and leaf water extract.

    PubMed

    Gutterman, Yitzchak; Chauser-Volfson, Elena

    2008-10-01

    Aloe arborescens plants, originating from the deserts of South Africa, are grown in the Introduction Garden at Sede Boker in the Negev Desert of Israel. In previous studies, we developed agro-technical methods to raise the content of secondary phenol metabolites (SPhMs) in the Aloe leaves. Plants that are subjected to repeated leaf pruning respond by increasing the content of their SPhMs. The SPhMs found in Aloe arborescens include barbaloin, aloenin and derivatives of aloeresin. Such compounds are used for many purposes, including human skin protection from sun and fire burns and high radiation, as products of the pharmaceutics and cosmetics industries, and as food supplements for treating stomach ulcers and diabetes. In the current study, the SPhMs were separated from pruned leaves of the same A. arborescens plants at the same time by two methods: (1) exudation by squeezing the tissues of the leaves, (2) immersion of the leaves' pruned cut bottom in water and collection of the extract. The exudates and extract were frozen, freeze-dried to a powder and the SPhMs were then separated by chromatography. The yield of powder from water extraction from pruned leaves was much lower than the yield from the exudates. However, higher percentages of the powder from the water extraction contained SPhMs (between 80 and 92.7%). The content of powder in leaf exudates from pruned leaves was much higher because the SPhMs were squeezed out from the cells and tissues. However, the percentages of SPhMs in this powder were much lower (between 39 and 62%).

  20. Multiresidue method for pesticide residue analysis in food of animal and plant origin based on GC or LC and MS or MS/MS.

    PubMed

    Muñoz, Eva; Muñoz, Gloria; Pineda, Laura; Serrahima, Eulalia; Centrich, Francesc

    2012-01-01

    A multiresidue method based on GC or LC and MS or MS/MS for the determination of 204 pesticides in diverse food matrixes of animal and plant origin is described. The method can include different stages of cleanup according to the chemical characteristics of each sample. Samples were extracted using accelerated solvent extraction. Those with a high fat content or that contained chlorophyll required further purification by gel permeation chromatography and/or SPE (ENVI-Carb). The methodology developed here was fully validated; the LOQs for the 204 pesticides are presented. The LOQ values lie between 0.01 to 0.02 mg/kg. However, in some cases, mainly in baby food, they were as low as 0.003 mg/kg, thereby meeting European Union requirements on maximum residue levels for pesticides, as outlined in European regulation 396/2005 and the Commission Directive 2003/13/EC. The procedure has been accredited for a wide scope of pesticides and matrixes by the Spanish Accreditation Body (ENAC) following ISO/IEC 17025:2005, as outlined in ENAC technical note NT-19.

  1. Simultaneous determination of multi-residue and multi-class antibiotics in aquaculture shrimps by UPLC-MS/MS.

    PubMed

    Saxena, Sushil Kumar; Rangasamy, Rajesh; Krishnan, Anoop A; Singh, Dhirendra P; Uke, Sumedh P; Malekadi, Praveen Kumar; Sengar, Anoop S; Mohamed, D Peer; Gupta, Ananda

    2018-09-15

    An accurate, reliable and fast multi-residue, multi-class method using ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) was developed and validated for simultaneous determination and quantification of 24 pharmacologically active substances of three different classes (Quinolones including fluoroquinolones, sulphonamides and tetracyclines) in aquaculture shrimps. Sample preparation involves extraction with acetonitrile containing 0.1% formic acid and followed by clean up with n-hexane and 0.1% methanol in water by UPLC-MS/MS within 8 min. The method was validated according to European Commission Decision 2002/657. Acceptable values were obtained for linearity (5-200 μg kg -1 ), specificity, Limit of Quantification (5-10 μg kg -1 ), recovery (between 83 and 100%), repeatability (RSD < 9%), within lab reproducibility (RSD < 15%), reproducibility (RSD ≤ 22%), decision limit (105-116 μg kg -1 ) and detection capability (110-132 μg kg -1 ). The validated method was applied to aquaculture shrimp samples from India. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Identification of clinical yeasts by Vitek MS system compared with API ID 32 C.

    PubMed

    Durán-Valle, M Teresa; Sanz-Rodríguez, Nuria; Muñoz-Paraíso, Carmen; Almagro-Moltó, María; Gómez-Garcés, José Luis

    2014-05-01

    We performed a clinical evaluation of the Vitek MS matrix-assisted laser desorption ionization-time-of-flight mass spectrometry (MALDI-TOF MS) system with the commercial database version 2.0 for rapid identification of medically important yeasts as compared with the conventional phenotypic method API ID 32 C. We tested 161 clinical isolates, nine isolates from culture collections and five reference strains. In case of discrepant results or no identification with one or both methods, molecular identification techniques were employed. Concordance between both methods was observed with 160/175 isolates (91.42%) and misidentifications by both systems occurred only when taxa were not included in the respective databases, i.e., one isolate of Candida etchellsii was identified as C. globosa by Vitek MS and two isolates of C. orthopsilosis were identified as C. parapsilosis by API ID 32 C. Vitek MS could not identify nine strains (5.14%) and API ID 32 C did not identify 13 (7.42%). Vitek MS was more reliable than API ID 32 C and reduced the time required for the identification of clinical isolates to only a few minutes.

  3. SIFT-MS and FA-MS methods for ambient gas phase analysis: developments and applications in the UK.

    PubMed

    Smith, David; Španěl, Patrik

    2015-04-21

    Selected ion flow tube mass spectrometry, SIFT-MS, a relatively new gas/vapour phase analytical method, is derived from the much earlier selected ion flow tube, SIFT, used for the study of gas phase ion-molecule reactions. Both the SIFT and SIFT-MS techniques were conceived and developed in the UK, the former at Birmingham University, the latter at Keele University along with the complementary flowing afterglow mass spectrometry, FA-MS, technique. The focus of this short review is largely to describe the origins, developments and, most importantly, the unique features of SIFT-MS as an analytical tool for ambient analysis and to indicate its growing use to analyse humid air, especially exhaled breath, its unique place as a on-line, real time analytical method and its growing use and applications as a non-invasive diagnostic in clinical diagnosis and therapeutic monitoring, principally within several UK universities and hospitals, and briefly in the wider world. A few case studies are outlined that show the potential of SIFT-MS and FA-MS in the detection and quantification of metabolites in exhaled breath as a step towards recognising pathophysiology indicative of disease and the presence of bacterial and fungal infection of the airways and lungs. Particular cases include the detection of Pseudomonas aeruginosa infection of the airways of patients with cystic fibrosis (SIFT-MS) and the measurement of total body water in patients with chronic kidney disease (FA-MS). The growing exploitation of SIFT-MS in other areas of research and commerce are briefly listed to show the wide utility of this unique UK-developed analytical method, and future prospects and developments are alluded to.

  4. Analysis of 100 pharmaceuticals and their degradates in water samples by liquid chromatography/quadrupole time-of-flight mass spectrometry.

    PubMed

    Ferrer, Imma; Thurman, E Michael

    2012-10-12

    A straightforward methodology for the chromatographic separation and accurate mass identification of 100 pharmaceuticals including some of their degradation products was developed using liquid chromatography/quadrupole time-of-flight mass spectrometry (LC/Q-TOF-MS). A table compiling the protonated or deprotonated exact masses for all compounds, as well as the exact mass of several fragment ions obtained by MS-MS is included. Excellent chromatographic separation was achieved by using 3.5 μm particle size columns and a slow and generic 30-min gradient. Isobaric and isomeric compounds (same nominal mass and same exact mass, respectively) were distinguished by various methods, including chromatography separation, MS-MS fragmentation, and isotopic signal identification. Method reporting limits of detection ranged from 1 to 1000 ng/L, after solid-phase extraction of 100mL aqueous samples. The methodology was successfully applied to the analysis of surface water impacted by wastewater effluent by identifying many of the pharmaceuticals and metabolites included in the list. Examples are given for some of the most unusual findings in environmental samples. This paper is meant to serve as a guide for those doing analysis of pharmaceuticals in environmental samples, by providing exact mass measurements of several well known, as well as newly identified and environmentally relevant pharmaceuticals in water samples. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. On the Ionization and Ion Transmission Efficiencies of Different ESI-MS Interfaces

    PubMed Central

    Cox, Jonathan T.; Marginean, Ioan; Smith, Richard D.; Tang, Keqi

    2014-01-01

    The achievable sensitivity of electrospray ionization mass spectrometry (ESI-MS) is largely determined by the ionization efficiency in the ESI source and ion transmission efficiency through the ESI-MS interface. These performance characteristics are difficult to evaluate and compare across multiple platforms as it is difficult to correlate electrical current measurements to actual analyte ions reaching the detector of a mass spectrometer. We present an effective method to evaluate the overall ion utilization efficiency of an ESI-MS interface by measuring the total gas phase ion current transmitted through the interface and correlating it to the observed ion abundance measured in the corresponding mass spectrum. Using this method we systematically studied the ion transmission and ionization efficiencies of different ESI-MS interface configurations, including a single emitter/single inlet capillary, single emitter/multi-inlet capillary, and a subambient pressure ionization with nanoelectrospray (SPIN) MS interface with a single emitter and an emitter array, respectively. Our experimental results indicate that the overall ion utilization efficiency of SPIN-MS interface configurations exceeds that of the inlet capillary-based ESI-MS interface configurations. PMID:25267087

  6. On the ionization and ion transmission efficiencies of different ESI-MS interfaces.

    PubMed

    Cox, Jonathan T; Marginean, Ioan; Smith, Richard D; Tang, Keqi

    2015-01-01

    The achievable sensitivity of electrospray ionization mass spectrometry (ESI-MS) is largely determined by the ionization efficiency in the ESI source and ion transmission efficiency through the ESI-MS interface. These performance characteristics are difficult to evaluate and compare across multiple platforms as it is difficult to correlate electrical current measurements to actual analyte ions reaching the detector of a mass spectrometer. We present an effective method to evaluate the overall ion utilization efficiency of an ESI-MS interface by measuring the total gas-phase ion current transmitted through the interface and correlating it to the observed ion abundance measured in the corresponding mass spectrum. Using this method, we systematically studied the ion transmission and ionization efficiencies of different ESI-MS interface configurations, including a single emitter/single inlet capillary, single emitter/multi-inlet capillary, and a subambient pressure ionization with nanoelectrospray (SPIN) MS interface with a single emitter and an emitter array, respectively. Our experimental results indicate that the overall ion utilization efficiency of SPIN-MS interface configurations exceeds that of the inlet capillary-based ESI-MS interface configurations.

  7. Analysis and comparison of glass fragments by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) and ICP-MS.

    PubMed

    Trejos, Tatiana; Montero, Shirly; Almirall, José R

    2003-08-01

    The discrimination potential of Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS) is compared with previously reported solution ICP-MS methods using external calibration (EC) with internal standardization and a newly reported solution isotope dilution (ID) method for the analysis of two different glass populations. A total of 91 different glass samples were used for the comparison study; refractive index and elemental composition were measured by the techniques mentioned above. One set consisted of 45 headlamps taken from a variety of automobiles that represents a range of 20 years of manufacturing dates. A second set consisted of 46 automotive glasses (side windows, rear windows, and windshields) representing casework glass from different vehicle manufacturers over several years. The element menu for the LA-ICP-MS and EC-ICP-MS methods include Mg, Al, Ca, Mn, Ce, Ti, Zr, Sb, Ga, Ba, Rb, Sm, Sr, Hf, La, and Pb. The ID method was limited to the analysis of two isotopes each of Mg, Sr, Zr, Sb, Ba, Sm, Hf, and Pb. Laser ablation analyses were performed with a Q switched Nd:YAG, 266 nm, 6 mJ output energy laser. The laser was used in depth profile mode while sampling using a 50 microm spot size for 50 sec at 10 Hz (500 shots). The typical bias for the analysis of NIST 612 by LA-ICP-MS was less than 5% in all cases and typically better than 5% for most isotopes. The precision for the vast majority of the element menu was determined generally less than 10% for all the methods when NIST 612 was measured (40 microg x g(-1)). Method detection limits (MDL) for the EC and LA-ICP-MS methods were similar and generally reported as less than 1 microg x g(-1) for the analysis of NIST 612. While the solution sample introduction methods using EC and ID presented excellent sensitivity and precision, these methods have the disadvantages of destroying the sample, and also involve complex sample preparation. The laser ablation method was simpler, faster, and produced comparable discrimination to the EC-ICP-MS and ID-ICP-MS. LA-ICP-MS can offer an excellent alternative to solution analysis of glass in forensic casework samples.

  8. Amino acid analysis in physiological samples by GC-MS with propyl chloroformate derivatization and iTRAQ-LC-MS/MS.

    PubMed

    Dettmer, Katja; Stevens, Axel P; Fagerer, Stephan R; Kaspar, Hannelore; Oefner, Peter J

    2012-01-01

    Two mass spectrometry-based methods for the quantitative analysis of free amino acids are described. The first method uses propyl chloroformate/propanol derivatization and gas chromatography-quadrupole mass spectrometry (GC-qMS) analysis in single-ion monitoring mode. Derivatization is carried out directly in aqueous samples, thereby allowing automation of the entire procedure, including addition of reagents, extraction, and injection into the GC-MS. The method delivers the quantification of 26 amino acids. The isobaric tagging for relative and absolute quantification (iTRAQ) method employs the labeling of amino acids with isobaric iTRAQ tags. The tags contain two different cleavable reporter ions, one for the sample and one for the standard, which are detected by fragmentation in a tandem mass spectrometer. Reversed-phase liquid chromatography of the labeled amino acids is performed prior to mass spectrometric analysis to separate isobaric amino acids. The commercial iTRAQ kit allows for the analysis of 42 physiological amino acids with a respective isotope-labeled standard for each of these 42 amino acids.

  9. A Collaborative Evaluation of LC-MS/MS Based Methods for BMAA Analysis: Soluble Bound BMAA Found to Be an Important Fraction.

    PubMed

    Faassen, Elisabeth J; Antoniou, Maria G; Beekman-Lukassen, Wendy; Blahova, Lucie; Chernova, Ekaterina; Christophoridis, Christophoros; Combes, Audrey; Edwards, Christine; Fastner, Jutta; Harmsen, Joop; Hiskia, Anastasia; Ilag, Leopold L; Kaloudis, Triantafyllos; Lopicic, Srdjan; Lürling, Miquel; Mazur-Marzec, Hanna; Meriluoto, Jussi; Porojan, Cristina; Viner-Mozzini, Yehudit; Zguna, Nadezda

    2016-02-29

    Exposure to β-N-methylamino-l-alanine (BMAA) might be linked to the incidence of amyotrophic lateral sclerosis, Alzheimer's disease and Parkinson's disease. Analytical chemistry plays a crucial role in determining human BMAA exposure and the associated health risk, but the performance of various analytical methods currently employed is rarely compared. A CYANOCOST initiated workshop was organized aimed at training scientists in BMAA analysis, creating mutual understanding and paving the way towards interlaboratory comparison exercises. During this workshop, we tested different methods (extraction followed by derivatization and liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) analysis, or directly followed by LC-MS/MS analysis) for trueness and intermediate precision. We adapted three workup methods for the underivatized analysis of animal, brain and cyanobacterial samples. Based on recovery of the internal standard D₃BMAA, the underivatized methods were accurate (mean recovery 80%) and precise (mean relative standard deviation 10%), except for the cyanobacterium Leptolyngbya. However, total BMAA concentrations in the positive controls (cycad seeds) showed higher variation (relative standard deviation 21%-32%), implying that D₃BMAA was not a good indicator for the release of BMAA from bound forms. Significant losses occurred during workup for the derivatized method, resulting in low recovery (<10%). Most BMAA was found in a trichloroacetic acid soluble, bound form and we recommend including this fraction during analysis.

  10. Improving CID, HCD, and ETD FT MS/MS degradome-peptidome identifications using high accuracy mass information

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shen, Yufeng; Tolic, Nikola; Purvine, Samuel O.

    2011-11-07

    The peptidome (i.e. processed and degraded forms of proteins) of e.g. blood can potentially provide insights into disease processes, as well as a source of candidate biomarkers that are unobtainable using conventional bottom-up proteomics approaches. MS dissociation methods, including CID, HCD, and ETD, can each contribute distinct identifications using conventional peptide identification methods (Shen et al. J. Proteome Res. 2011), but such samples still pose significant analysis and informatics challenges. In this work, we explored a simple approach for better utilization of high accuracy fragment ion mass measurements provided e.g. by FT MS/MS and demonstrate significant improvements relative to conventionalmore » descriptive and probabilistic scores methods. For example, at the same FDR level we identified 20-40% more peptides than SEQUEST and Mascot scoring methods using high accuracy fragment ion information (e.g., <10 mass errors) from CID, HCD, and ETD spectra. Species identified covered >90% of all those identified from SEQUEST, Mascot, and MS-GF scoring methods. Additionally, we found that the merging the different fragment spectra provided >60% more species using the UStags method than achieved previously, and enabled >1000 peptidome components to be identified from a single human blood plasma sample with a 0.6% peptide-level FDR, and providing an improved basis for investigation of potentially disease-related peptidome components.« less

  11. Hooked differential mobility spectrometry apparatus and method therefore

    DOEpatents

    Shvartsburg, Alexandre A [Richland, WA; Tang, Keqi [Richland, WA; Ibrahim, Yehia M [Richland, WA; Smith, Richard D [Richland, WA

    2009-02-17

    Disclosed are a device and method for improved interfacing of differential mobility spectrometry (DMS) or field asymmetric waveform ion mobility spectrometry (FAIMS) analyzers of substantially planar geometry to subsequent or preceding instrument stages. Interfacing is achieved using curved DMS elements, where a thick ion beam emitted by planar DMS analyzers or injected into them for ion filtering is compressed to the gap median by DMS ion focusing effect in a spatially inhomogeneous electric field. Resulting thinner beams are more effectively transmitted through necessarily constrained conductance limit apertures to subsequent instrument stages operated at a pressure lower than DMS, and/or more effectively injected into planar DMS analyzers. The technology is synergetic with slit apertures, slit aperture/ion funnels, and high-pressure ion funnel interfaces known in the art which allow for increasing cross-sectional area of MS inlets. The invention may be used in integrated analytical platforms, including, e.g., DMS/MS, LC/DMS/MS, and DMS/IMS/MS that could replace and/or enhance current LC/MS methods, e.g., for proteomics research.

  12. New Trends in Pesticide Residue Analysis in Cereals, Nutraceuticals, Baby Foods, and Related Processed Consumer Products.

    PubMed

    Raina-Fulton, Renata

    2015-01-01

    Pesticide residue methods have been developed for a wide variety of food products including cereal-based foods, nutraceuticals and related plant products, and baby foods. These cereal, fruit, vegetable, and plant-based products provide the basis for many processed consumer products. For cereal and nutraceuticals, which are dry sample products, a modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) method has been used with additional steps to allow wetting of the dry sample matrix and subsequent cleanup using dispersive or cartridge format SPE to reduce matrix effects. More processed foods may have lower pesticide concentrations but higher co-extracts that can lead to signal suppression or enhancement with MS detection. For complex matrixes, GC/MS/MS or LC/electrospray ionization (positive or negative ion)-MS/MS is more frequently used. The extraction and cleanup methods vary with different sample types particularly for cereal-based products, and these different approaches are discussed in this review. General instrument considerations are also discussed.

  13. Validation of a new screening, determinative, and confirmatory multi-residue method for nitroimidazoles and their hydroxy metabolites in turkey muscle tissue by liquid chromatography-tandem mass spectrometry.

    PubMed

    Boison, Joe O; Asea, Philip A; Matus, Johanna L

    2012-08-01

    A new and sensitive multi-residue method (MRM) with detection by LC-MS/MS was developed and validated for the screening, determination, and confirmation of residues of 7 nitroimidazoles and 3 of their metabolites in turkey muscle tissues at concentrations ≥ 0.05 ng/g. The compounds were extracted into a solvent with an alkali salt. Sample clean-up and concentration was then done by solid-phase extraction (SPE) and the compounds were quantified by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The characteristic parameters including repeatability, selectivity, ruggedness, stability, level of quantification, and level of confirmation for the new method were determined. Method validation was achieved by independent verification of the parameters measured during method characterization. The seven nitroimidazoles included are metronidazole (MTZ), ronidazole (RNZ), dimetridazole (DMZ), tinidazole (TNZ), ornidazole (ONZ), ipronidazole (IPR), and carnidazole (CNZ). It was discovered during the single laboratory validation of the method that five of the seven nitroimidazoles (i.e. metronidazole, dimetridazole, tinidazole, ornidazole and ipronidazole) and the 3 metabolites (1-(2-hydroxyethyl)-2-hydroxymethyl-5-nitroimidazole (MTZ-OH), 2-hydroxymethyl-1-methyl-5-nitroimidazole (HMMNI, the common metabolite of ronidazole and dimetridazole), and 1-methyl-2-(2'-hydroxyisopropyl)-5-nitroimidazole (IPR-OH) included in this study could be detected, confirmed, and quantified accurately whereas RNZ and CNZ could only be detected and confirmed but not accurately quantified. © Her Majesty the Queen in Right of Canada as Represented by the Minister of Agriculture and Agri-food Canada 2012.

  14. Quantitative Analysis of Tetramethylenedisulfotetramine ("Tetramine") Spiked into Beverages by Liquid Chromatography Tandem Mass Spectrometry with Validation by Gas Chromatography Mass Spectrometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Owens, J; Hok, S; Alcaraz, A

    Tetramethylenedisulfotetramine, commonly known as tetramine, is a highly neurotoxic rodenticide (human oral LD{sub 50} = 0.1 mg/kg) used in hundreds of deliberate food poisoning events in China. Here we describe a method for quantitation of tetramine spiked into beverages, including milk, juice, tea, cola, and water and cleaned up by C8 solid phase extraction and liquid-liquid extraction. Quantitation by high performance liquid chromatography tandem mass spectrometry (LC/MS/MS) was based upon fragmentation of m/z 347 to m/z 268. The method was validated by gas chromatography mass spectrometry (GC/MS) operated in SIM mode for ions m/z 212, 240, and 360. The limitmore » of quantitation was 0.10 {micro}g/mL by LC/MS/MS versus 0.15 {micro}g/mL for GC/MS. Fortifications of the beverages at 2.5 {micro}g/mL and 0.25 {micro}g/mL were recovered ranging from 73-128% by liquid-liquid extraction for GC/MS analysis, 13-96% by SPE and 10-101% by liquid-liquid extraction for LC/MS/MS analysis.« less

  15. Screening for anabolic steroids in urine of forensic cases using fully automated solid phase extraction and LC-MS-MS.

    PubMed

    Andersen, David W; Linnet, Kristian

    2014-01-01

    A screening method for 18 frequently measured exogenous anabolic steroids and the testosterone/epitestosterone (T/E) ratio in forensic cases has been developed and validated. The method involves a fully automated sample preparation including enzyme treatment, addition of internal standards and solid phase extraction followed by analysis by liquid chromatography-tandem mass spectrometry (LC-MS-MS) using electrospray ionization with adduct formation for two compounds. Urine samples from 580 forensic cases were analyzed to determine the T/E ratio and occurrence of exogenous anabolic steroids. Extraction recoveries ranged from 77 to 95%, matrix effects from 48 to 78%, overall process efficiencies from 40 to 54% and the lower limit of identification ranged from 2 to 40 ng/mL. In the 580 urine samples analyzed from routine forensic cases, 17 (2.9%) were found positive for one or more anabolic steroids. Only seven different steroids including testosterone were found in the material, suggesting that only a small number of common steroids are likely to occur in a forensic context. The steroids were often in high concentrations (>100 ng/mL), and a combination of steroids and/or other drugs of abuse were seen in the majority of cases. The method presented serves as a fast and automated screening procedure, proving the suitability of LC-MS-MS for analyzing anabolic steroids. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Quantitation of intracellular purine intermediates in different Corynebacteria using electrospray LC-MS/MS.

    PubMed

    Peifer, Susanne; Schneider, Konstantin; Nürenberg, Gudrun; Volmer, Dietrich A; Heinzle, Elmar

    2012-11-01

    Intermediates of the purine biosynthesis pathway play key roles in cellular metabolism including nucleic acid synthesis and signal mediation. In addition, they are also of major interest to the biotechnological industry as several intermediates either possess flavor-enhancing characteristics or are applied in medical therapy. In this study, we have developed an analytical method for quantitation of 12 intermediates from the purine biosynthesis pathway including important nucleotides and their corresponding nucleosides and nucleobases. The approach comprised a single-step acidic extraction/quenching procedure, followed by quantitative electrospray LC-MS/MS analysis. The assay was validated in terms of accuracy, precision, reproducibility, and applicability for complex biological matrices. The method was subsequently applied for determination of free intracellular pool sizes of purine biosynthetic pathway intermediates in the two Gram-positive bacteria Corynebacterium glutamicum and Corynebacterium ammoniagenes. Importantly, no ion pair reagents were applied in this approach as usually required for liquid chromatography analysis of large classes of diverse metabolites.

  17. Removal of detergents from proteins and peptides in a spin-column format.

    PubMed

    Antharavally, Babu S

    2012-08-01

    To enable downstream analysis, it is critical to remove unbound detergents from protein and peptide samples. This unit describes the use of a high-performance resin that offers exceptional detergent removal for proteins and peptides. The easy-to-use spin format significantly improves results over the standard drip column and batch methodologies, with >95% removal of 1% to 5% detergents, including SDS, sodium deoxycholate, CHAPS, Triton X-100, Triton X-114, NP-40, Brij-35, octyl glucoside, octyl thioglucoside, and lauryl maltoside, with high recovery of proteins and peptides. Detergent removal efficiency is evaluated using colorimetric methods and mass spectrometry (MS). BSA tryptic peptides have been successfully analyzed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and matrix-assisted laser desorption/ionization (MALDI)-MS for identification of protein, following detergent removal using the resin. Advantages of this method include speed (less than 15 min), efficient detergent removal, and high recovery of proteins and peptides. © 2012 by John Wiley & Sons, Inc.

  18. Cost Savings Realized by Implementation of Routine Microbiological Identification by Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry

    PubMed Central

    Alby, Kevin; Kerr, Alan; Jones, Melissa; Gilligan, Peter H.

    2015-01-01

    Matrix-assisted laser desorption ionization–time of flight (MALDI-TOF) mass spectrometry (MS) is an emerging technology for rapid identification of bacterial and fungal isolates. In comparison to conventional methods, this technology is much less labor intensive and can provide accurate and reliable results in minutes from a single isolated colony. We compared the cost of performing the bioMérieux Vitek MALDI-TOF MS with conventional microbiological methods to determine the amount saved by the laboratory by converting to the new technology. Identification costs for 21,930 isolates collected between April 1, 2013, and March 31, 2014, were directly compared for MALDI-TOF MS and conventional methodologies. These isolates were composed of commonly isolated organisms, including commonly encountered aerobic and facultative bacteria and yeast but excluding anaerobes and filamentous fungi. Mycobacterium tuberculosis complex and rapidly growing mycobacteria were also evaluated for a 5-month period during the study. Reagent costs and a total cost analysis that included technologist time in addition to reagent expenses and maintenance service agreement costs were analyzed as part of this study. The use of MALDI-TOF MS equated to a net savings of $69,108.61, or 87.8%, in reagent costs annually compared to traditional methods. When total costs are calculated to include technologist time and maintenance costs, traditional identification would have cost $142,532.69, versus $68,886.51 with the MALDI-TOF MS method, resulting in a laboratory savings of $73,646.18, or 51.7%, annually by adopting the new technology. The initial cost of the instrument at our usage level would be offset in about 3 years. MALDI-TOF MS not only represents an innovative technology for the rapid and accurate identification of bacterial and fungal isolates, it also provides a significant cost savings for the laboratory. PMID:25994167

  19. Cost Savings Realized by Implementation of Routine Microbiological Identification by Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry.

    PubMed

    Tran, Anthony; Alby, Kevin; Kerr, Alan; Jones, Melissa; Gilligan, Peter H

    2015-08-01

    Matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry (MS) is an emerging technology for rapid identification of bacterial and fungal isolates. In comparison to conventional methods, this technology is much less labor intensive and can provide accurate and reliable results in minutes from a single isolated colony. We compared the cost of performing the bioMérieux Vitek MALDI-TOF MS with conventional microbiological methods to determine the amount saved by the laboratory by converting to the new technology. Identification costs for 21,930 isolates collected between April 1, 2013, and March 31, 2014, were directly compared for MALDI-TOF MS and conventional methodologies. These isolates were composed of commonly isolated organisms, including commonly encountered aerobic and facultative bacteria and yeast but excluding anaerobes and filamentous fungi. Mycobacterium tuberculosis complex and rapidly growing mycobacteria were also evaluated for a 5-month period during the study. Reagent costs and a total cost analysis that included technologist time in addition to reagent expenses and maintenance service agreement costs were analyzed as part of this study. The use of MALDI-TOF MS equated to a net savings of $69,108.61, or 87.8%, in reagent costs annually compared to traditional methods. When total costs are calculated to include technologist time and maintenance costs, traditional identification would have cost $142,532.69, versus $68,886.51 with the MALDI-TOF MS method, resulting in a laboratory savings of $73,646.18, or 51.7%, annually by adopting the new technology. The initial cost of the instrument at our usage level would be offset in about 3 years. MALDI-TOF MS not only represents an innovative technology for the rapid and accurate identification of bacterial and fungal isolates, it also provides a significant cost savings for the laboratory. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  20. Comparative analysis of storage conditions and homogenization methods for tick and flea species for identification by MALDI-TOF MS.

    PubMed

    Nebbak, A; El Hamzaoui, B; Berenger, J-M; Bitam, I; Raoult, D; Almeras, L; Parola, P

    2017-12-01

    Ticks and fleas are vectors for numerous human and animal pathogens. Controlling them, which is important in combating such diseases, requires accurate identification, to distinguish between vector and non-vector species. Recently, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) was applied to the rapid identification of arthropods. The growth of this promising tool, however, requires guidelines to be established. To this end, standardization protocols were applied to species of Rhipicephalus sanguineus (Ixodida: Ixodidae) Latreille and Ctenocephalides felis felis (Siphonaptera: Pulicidae) Bouché, including the automation of sample homogenization using two homogenizer devices, and varied sample preservation modes for a period of 1-6 months. The MS spectra were then compared with those obtained from manual pestle grinding, the standard homogenization method. Both automated methods generated intense, reproducible MS spectra from fresh specimens. Frozen storage methods appeared to represent the best preservation mode, for up to 6 months, while storage in ethanol is also possible, with some caveats for tick specimens. Carnoy's buffer, however, was shown to be less compatible with MS analysis for the purpose of identifying ticks or fleas. These standard protocols for MALDI-TOF MS arthropod identification should be complemented by additional MS spectrum quality controls, to generalize their use in monitoring arthropods of medical interest. © 2017 The Royal Entomological Society.

  1. Potential Applications of Biotechnology to Aerospace Materials.

    DTIC Science & Technology

    1986-11-01

    sulfate:(1) ms + 202 a msO4 where m is a bivalent metal. In the indirect method of bioleach- ing, the metal sulfide is oxidized by ferric ion: ms + 2Fe...possibility exists of using bioleaching or biosorption for recovery of strategic and precious metals such as cobalt, nickel, zinc, arsenic, gallium ...workshop that could be of significant interest to the Materials Laboratory including acetylene compounds , adhesives, structural materials, lubricants, and

  2. Synthetic Peptide Arrays for Pathway-Level Protein Monitoring by Liquid Chromatography-Tandem Mass Spectrometry*

    PubMed Central

    Hewel, Johannes A.; Liu, Jian; Onishi, Kento; Fong, Vincent; Chandran, Shamanta; Olsen, Jonathan B.; Pogoutse, Oxana; Schutkowski, Mike; Wenschuh, Holger; Winkler, Dirk F. H.; Eckler, Larry; Zandstra, Peter W.; Emili, Andrew

    2010-01-01

    Effective methods to detect and quantify functionally linked regulatory proteins in complex biological samples are essential for investigating mammalian signaling pathways. Traditional immunoassays depend on proprietary reagents that are difficult to generate and multiplex, whereas global proteomic profiling can be tedious and can miss low abundance proteins. Here, we report a target-driven liquid chromatography-tandem mass spectrometry (LC-MS/MS) strategy for selectively examining the levels of multiple low abundance components of signaling pathways which are refractory to standard shotgun screening procedures and hence appear limited in current MS/MS repositories. Our stepwise approach consists of: (i) synthesizing microscale peptide arrays, including heavy isotope-labeled internal standards, for use as high quality references to (ii) build empirically validated high density LC-MS/MS detection assays with a retention time scheduling system that can be used to (iii) identify and quantify endogenous low abundance protein targets in complex biological mixtures with high accuracy by correlation to a spectral database using new software tools. The method offers a flexible, rapid, and cost-effective means for routine proteomic exploration of biological systems including “label-free” quantification, while minimizing spurious interferences. As proof-of-concept, we have examined the abundance of transcription factors and protein kinases mediating pluripotency and self-renewal in embryonic stem cell populations. PMID:20467045

  3. Validation of an analytical method for nitrous oxide (N2O) laughing gas by headspace gas chromatography coupled to mass spectrometry (HS-GC-MS): forensic application to a lethal intoxication.

    PubMed

    Giuliani, N; Beyer, J; Augsburger, M; Varlet, V

    2015-03-01

    Drug abuse is a widespread problem affecting both teenagers and adults. Nitrous oxide is becoming increasingly popular as an inhalation drug, causing harmful neurological and hematological effects. Some gas chromatography-mass spectrometry (GC-MS) methods for nitrous oxide measurement have been previously described. The main drawbacks of these methods include a lack of sensitivity for forensic applications; including an inability to quantitatively determine the concentration of gas present. The following study provides a validated method using HS-GC-MS which incorporates hydrogen sulfide as a suitable internal standard allowing the quantification of nitrous oxide. Upon analysis, sample and internal standard have similar retention times and are eluted quickly from the molecular sieve 5Å PLOT capillary column and the Porabond Q column therefore providing rapid data collection whilst preserving well defined peaks. After validation, the method has been applied to a real case of N2O intoxication indicating concentrations in a mono-intoxication. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. MS/MS library facilitated MRM quantification of native peptides prepared by denaturing ultrafiltration

    PubMed Central

    2012-01-01

    Naturally occurring native peptides provide important information about physiological states of an organism and its changes in disease conditions but protocols and methods for assessing their abundance are not well-developed. In this paper, we describe a simple procedure for the quantification of non-tryptic peptides in body fluids. The workflow includes an enrichment step followed by two-dimensional fractionation of native peptides and MS/MS data management facilitating the design and validation of LC- MRM MS assays. The added value of the workflow is demonstrated in the development of a triplex LC-MRM MS assay used for quantification of peptides potentially associated with the progression of liver disease to hepatocellular carcinoma. PMID:22304756

  5. Screening of 23 β-lactams in foodstuffs by LC-MS/MS using an alkaline QuEChERS-like extraction.

    PubMed

    Bessaire, Thomas; Mujahid, Claudia; Beck, Andrea; Tarres, Adrienne; Savoy, Marie-Claude; Woo, Pei-Mun; Mottier, Pascal; Desmarchelier, Aurélien

    2018-04-01

    A fast and robust high performance LC-MS/MS screening method was developed for the analysis of β-lactam antibiotics in foods of animal origin: eggs, raw milk, processed dairy ingredients, infant formula, and meat- and fish-based products including baby foods. QuEChERS extraction with some adaptations enabled 23 drugs to be simultaneously monitored. Screening target concentrations were set at levels adequate to ensure compliance with current European, Chinese, US and Canadian regulations. The method was fully validated according to the European Community Reference Laboratories Residues Guidelines using 93 food samples of different composition. False-negative and false-positive rates were below 5% for all analytes. The method is adequate for use in high-routine laboratories. A 1-year study was additionally conducted to assess the stability of the 23 analytes in the working standard solution.

  6. Simultaneous analysis of coccidiostats and sulfonamides in non-target feed by HPLC-MS/MS and validation following the Commission Decision 2002/657/EC.

    PubMed

    Gavilán, Rosa Elvira; Nebot, Carolina; Patyra, Ewelina; Miranda, Jose Manuel; Franco, Carlos Manuel; Cepeda, Alberto

    2018-05-02

    Taking into consideration the maximum level for coccidiostats included in the European Regulation 574/2011 and the fact that the presence of residues of sulfonamides in non-target feed is forbidden, the aim of this article is to present an analytical method based on HPLC-MS/MS for the identification and quantification of sulfonamides and coccidiostats in non-target feeds. The method was validated following Decision 2002/657/EC and recovery, repeatability, and reproducibility were within the limits stablished in the Decision. For coccidiostats, the decision limit and detection capability were calculated for the different species taking into account the maximum level allowed in Regulation 574/2011. The applicability of the method was investigated in 50 feed samples collected from dairy farms, 50 obtained from feed mills, and 10 interlaboratory feed samples.

  7. Qualitative and quantitative analysis of flavonoids in Sophora tonkinensis by LC/MS and HPLC.

    PubMed

    He, Chang-Ming; Cheng, Zhi-Hong; Chen, Dao-Feng

    2013-11-01

    To develop analytical methods for the identification and determination of the flavonoids in Sophora tonkinensis for comprehensive quality evaluation. An HPLC-DAD-ESI-MS method was used for the separation and characterization of the flavonoids in S. tonkinensis, and a liquid chromatographic method was employed to simultaneously determine five major active flavonoids in this crude drug. Seventeen flavonoids were identified, among which, seven were unambiguously identified as trifolirhizin, quercetin, formononetin, macckiain, kurarinone, sophoranone, and sophoranochromene by comparing their retention times, and UV and MS spectra with those of the authentic compounds, and the other ten flavonoids were tentatively identified by comparing their UV and MS/MS spectra with those of literature data. Furthermore, five major active flavonoids, including trifolirhizin, quercetin, maackiain, sophoranone, and sophoranochromene were determined in S. tonkinensis. All calibration curves expressed good linearity (r > 0.999 8) within the test ranges, and the recovery from this method was 96.40%-104.43%. The developed HPLC method was successfully applied to quantitatively determine the five flavonoids in seventeen samples of S. tonkinensis. The developed method rapidly characterized the bioactive flavonoids of S. tonkinensis, and could be readily utilized to enhance the quality assurance approaches for this traditional Chinese medicine. Copyright © 2013 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.

  8. Challenges for Detecting Valproic Acid in a Nontargeted Urine Drug Screening Method.

    PubMed

    Pope, Jeffrey D; Black, Marion J; Drummer, Olaf H; Schneider, Hans G

    2017-08-01

    Valproic acid (VPA) is a widely prescribed medicine, and acute toxicity is possible. As such, it should be included in any nontargeted urine drug screening method. In many published liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS/MS) methods, VPA is usually measured using a pseudo-multiple reaction monitoring (MRM) transition. We investigate a simple ultra-high-performance liquid chromatography-quadrupole time-of-flight (QTof) approach to detect the presence of VPA with more confidence. Three commercially sourced VPA metabolites were characterized and added to a nontargeted high-resolution MS urine drug screening method. All analyses were performed on a Waters Xevo G2-XS LC-QTof in negative electrospray ionization mode. The mass detector was operated in MS mode, and data were processed with UNIFI software. Sixty-eight patient urine samples, which were previously identified by a well-established gas chromatography-MS method as containing VPA, were analyzed on the Waters Xevo G2-XS LC-QTof, to validate this approach. VPA metabolite standards were characterized, and their detection data were added to the broad drug screening library. VPA metabolites were readily detectable in the urine of patients taking VPA. The inclusion of characterized VPA metabolites provides a simple and reliable method enabling the detection of VPA in nontargeted urine drug screening.

  9. UPLC-MS/MS Method for Simultaneous Determination of Three Major Metabolites of Mequindox in Holothurian

    PubMed Central

    Liu, Huihui; Han, Dianfeng; Huang, Hui; Xu, Yingjiang; Gong, Xianghong

    2018-01-01

    This study developed an ultraperformance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method for the detection of three major metabolites of mequindox, including 3-methyl-quinoxaline-2-carboxylic acid, 1-desoxymequindox, and 1,4-bisdesoxymequindox (MQCA, 1-DMEQ, and BDMEQ), in holothurian. Target analytes were simplified with ultrasound-assisted acidolysis extracted without complicated enzymolysis steps. After that, each sample was centrifuged and purified by an Oasis MAX cartridge. Then, the processed samples were separated and monitored by UPLC-MS/MS. This developed method has been validated according to FDA criteria. At fortified levels of 2, 10, and 20 μg/kg, recoveries ranged from 82.5% to 93.5% with the intraday RSD less than 7.27% and interday RSD less than 11.8%. The limit of detection (LOD) of all the three metabolites ranged from 0.21 to 0.48 μg/kg, while the limit of quantification (LOQ) ranged from 0.79 to 1.59 μg/kg. On application to commercial samples, 14 of 20 samples were detected positive for the three target analytes, with positive rate at 70 percentage. The result indicated that this method was specific, sensitive, and suitable for the quantification and conformation of the three major metabolites of MEQ in holothurian. PMID:29805832

  10. UPLC-MS/MS Method for Simultaneous Determination of Three Major Metabolites of Mequindox in Holothurian.

    PubMed

    Liu, Huihui; Ren, Chuanbo; Han, Dianfeng; Huang, Hui; Zou, Rongjie; Zhang, Huawei; Xu, Yingjiang; Gong, Xianghong; Zhang, Xiuzhen; Li, Yanshen

    2018-01-01

    This study developed an ultraperformance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method for the detection of three major metabolites of mequindox, including 3-methyl-quinoxaline-2-carboxylic acid, 1-desoxymequindox, and 1,4-bisdesoxymequindox (MQCA, 1-DMEQ, and BDMEQ), in holothurian. Target analytes were simplified with ultrasound-assisted acidolysis extracted without complicated enzymolysis steps. After that, each sample was centrifuged and purified by an Oasis MAX cartridge. Then, the processed samples were separated and monitored by UPLC-MS/MS. This developed method has been validated according to FDA criteria. At fortified levels of 2, 10, and 20  μ g/kg, recoveries ranged from 82.5% to 93.5% with the intraday RSD less than 7.27% and interday RSD less than 11.8%. The limit of detection (LOD) of all the three metabolites ranged from 0.21 to 0.48  μ g/kg, while the limit of quantification (LOQ) ranged from 0.79 to 1.59  μ g/kg. On application to commercial samples, 14 of 20 samples were detected positive for the three target analytes, with positive rate at 70 percentage. The result indicated that this method was specific, sensitive, and suitable for the quantification and conformation of the three major metabolites of MEQ in holothurian.

  11. Multiclass screening of >200 pharmaceutical and other residues in aquatic foods by ultrahigh-performance liquid chromatography-quadrupole-Orbitrap mass spectrometry.

    PubMed

    Kong, Cong; Wang, Yang; Huang, Yuanfei; Yu, Huijuan

    2018-05-11

    A quick screening method of more than 200 pharmaceutical and other residues in aquatic foods based on ultrahigh-performance liquid chromatography-quadrupole-Orbitrap mass spectrometry (UHPLC-Q/Orbitrap MS) was established. In this method, after the addition of 200 μL of 1 M EDTA-Na 2 , 2 g of each sample homogenate was extracted successively with 10 mL of acetonitrile and 10 mL of ethyl acetate. The extracts were combined, dried under nitrogen flow, and redissolved in 0.1% formic acid in acetonitrile/water (4:6, v/v) for analysis. The prepared samples were analyzed by UHPLC- Q/Orbitrap MS system in Full MS/ddMS 2 (full-scan data-dependent MS/MS) mode. Compound identification was performed through comparison of the sample data with the database for standard chemicals, including the retention time, precursor ion, product ions, and isotope pattern for all 206 compounds. Five different aquatic food matrices (carp, shrimp, crab, eel, and mussel) spiked with the analytes at 1, 10, and 50 ng/g were evaluated to assess recoveries, precision, matrix effects, stability, and detection limits using the method. UHPLC analyses required 25 min, and 178-200 analytes met identification criteria at 50 ng/g depending on the matrix. Furthermore, practical application of this method for real samples displayed strong screening capability. Graphical abstract A quick screening method of >200 pharmaceutical and other residues in aquatic foods based on ultrahighperformance liquid chromatography-quadrupole-Orbitrap mass spectrometer was established. Fivedifferent aquatic food matrices, including carp, shrimp, crab, eel and mussel, were studied to evaluatescreen limit at 1, 10 and 50 μg·kg-1 level. Results suggest the high reliability, high time-efficiency and goodsimplicity of the method.

  12. Rapid sample preparation and fast GC-MS/MS for the analysis of pesticides and environmental contaminants in fish

    USDA-ARS?s Scientific Manuscript database

    A rapid high-throughput analytical method for the simultaneous determination of pesticides and environmental contaminants, including polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (PBDEs) and flame retardants (FRs) in fish was developed and ...

  13. Experimental Methods for Protein Interaction Identification and Characterization

    NASA Astrophysics Data System (ADS)

    Uetz, Peter; Titz, Björn; Cagney, Gerard

    There are dozens of methods for the detection of protein-protein interactions but they fall into a few broad categories. Fragment complementation assays such as the yeast two-hybrid (Y2H) system are based on split proteins that are functionally reconstituted by fusions of interacting proteins. Biophysical methods include structure determination and mass spectrometric (MS) identification of proteins in complexes. Biochemical methods include methods such as far western blotting and peptide arrays. Only the Y2H and protein complex purification combined with MS have been used on a larger scale. Due to the lack of data it is still difficult to compare these methods with respect to their efficiency and error rates. Current data does not favor any particular method and thus multiple experimental approaches are necessary to maximally cover the interactome of any target cell or organism.

  14. Statistical characterization of multiple-reaction monitoring mass spectrometry (MRM-MS) assays for quantitative proteomics

    PubMed Central

    2012-01-01

    Multiple reaction monitoring mass spectrometry (MRM-MS) with stable isotope dilution (SID) is increasingly becoming a widely accepted assay for the quantification of proteins and peptides. These assays have shown great promise in relatively high throughput verification of candidate biomarkers. While the use of MRM-MS assays is well established in the small molecule realm, their introduction and use in proteomics is relatively recent. As such, statistical and computational methods for the analysis of MRM-MS data from proteins and peptides are still being developed. Based on our extensive experience with analyzing a wide range of SID-MRM-MS data, we set forth a methodology for analysis that encompasses significant aspects ranging from data quality assessment, assay characterization including calibration curves, limits of detection (LOD) and quantification (LOQ), and measurement of intra- and interlaboratory precision. We draw upon publicly available seminal datasets to illustrate our methods and algorithms. PMID:23176545

  15. Statistical characterization of multiple-reaction monitoring mass spectrometry (MRM-MS) assays for quantitative proteomics.

    PubMed

    Mani, D R; Abbatiello, Susan E; Carr, Steven A

    2012-01-01

    Multiple reaction monitoring mass spectrometry (MRM-MS) with stable isotope dilution (SID) is increasingly becoming a widely accepted assay for the quantification of proteins and peptides. These assays have shown great promise in relatively high throughput verification of candidate biomarkers. While the use of MRM-MS assays is well established in the small molecule realm, their introduction and use in proteomics is relatively recent. As such, statistical and computational methods for the analysis of MRM-MS data from proteins and peptides are still being developed. Based on our extensive experience with analyzing a wide range of SID-MRM-MS data, we set forth a methodology for analysis that encompasses significant aspects ranging from data quality assessment, assay characterization including calibration curves, limits of detection (LOD) and quantification (LOQ), and measurement of intra- and interlaboratory precision. We draw upon publicly available seminal datasets to illustrate our methods and algorithms.

  16. A Derivative Method with Free Radical Oxidation to Predict Resveratrol Metabolites by Tandem Mass Spectrometry

    PubMed Central

    Liu, Wangta; Shiue, Yow-Ling; Lin, Yi-Reng; Lin, Hugo You-Hsien; Liang, Shih-Shin

    2015-01-01

    In this study, we demonstrated an oxidative method with free radical to generate 3,5,4′-trihydroxy-trans-stilbene (trans-resveratrol) metabolites and detect sequentially by an autosampler coupling with liquid chromatography electrospray ionization tandem mass spectrometer (LC-ESI–MS/MS). In this oxidative method, the free radical initiator, ammonium persulfate (APS), was placed in a sample bottle containing resveratrol to produce oxidative derivatives, and the reaction progress was tracked by autosampler sequencing. Resveratrol, a natural product with purported cancer preventative qualities, produces metabolites including dihydroresveratrol, 3,4′-dihydroxy-trans-stilbene, lunularin, resveratrol monosulfate, and dihydroresveratrol monosulfate by free radical oxidation. Using APS free radical, the concentrations of resveratrol derivatives differ as a function of time. Besides simple, convenient and time- and labor saving, the advantages of free radical oxidative method of its in situ generation of oxidative derivatives followed by LC-ESI–MS/MS can be utilized to evaluate different metabolites in various conditions. PMID:27594817

  17. A Derivative Method with Free Radical Oxidation to Predict Resveratrol Metabolites by Tandem Mass Spectrometry.

    PubMed

    Liu, Wangta; Shiue, Yow-Ling; Lin, Yi-Reng; Lin, Hugo You-Hsien; Liang, Shih-Shin

    2015-10-01

    In this study, we demonstrated an oxidative method with free radical to generate 3,5,4'-trihydroxy- trans -stilbene ( trans -resveratrol) metabolites and detect sequentially by an autosampler coupling with liquid chromatography electrospray ionization tandem mass spectrometer (LC-ESI-MS/MS). In this oxidative method, the free radical initiator, ammonium persulfate (APS), was placed in a sample bottle containing resveratrol to produce oxidative derivatives, and the reaction progress was tracked by autosampler sequencing. Resveratrol, a natural product with purported cancer preventative qualities, produces metabolites including dihydroresveratrol, 3,4'-dihydroxy- trans -stilbene, lunularin, resveratrol monosulfate, and dihydroresveratrol monosulfate by free radical oxidation. Using APS free radical, the concentrations of resveratrol derivatives differ as a function of time. Besides simple, convenient and time- and labor saving, the advantages of free radical oxidative method of its in situ generation of oxidative derivatives followed by LC-ESI-MS/MS can be utilized to evaluate different metabolites in various conditions.

  18. Simultaneous screening and quantification of 29 drugs of abuse in oral fluid by solid-phase extraction and ultraperformance LC-MS/MS.

    PubMed

    Badawi, Nora; Simonsen, Kirsten Wiese; Steentoft, Anni; Bernhoft, Inger Marie; Linnet, Kristian

    2009-11-01

    The European DRUID (Driving under the Influence of Drugs, Alcohol And Medicines) project calls for analysis of oral fluid (OF) samples, collected randomly and anonymously at the roadside from drivers in Denmark throughout 2008-2009. To analyze these samples we developed an ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for detection of 29 drugs and illicit compounds in OF. The drugs detected were opioids, amphetamines, cocaine, benzodiazepines, and Delta-9-tetrahydrocannabinol. Solid-phase extraction was performed with a Gilson ASPEC XL4 system equipped with Bond Elut Certify sample cartridges. OF samples (200 mg) diluted with 5 mL of ammonium acetate/methanol (vol/vol 90:10) buffer were applied to the columns and eluted with 3 mL of acetonitrile with aqueous ammonium hydroxide. Target drugs were quantified by use of a Waters ACQUITY UPLC system coupled to a Waters Quattro Premier XE triple quadrupole (positive electrospray ionization mode, multiple reaction monitoring mode). Extraction recoveries were 36%-114% for all analytes, including Delta-9-tetrahydrocannabinol and benzoylecgonine. The lower limit of quantification was 0.5 mug/kg for all analytes. Total imprecision (CV) was 5.9%-19.4%. With the use of deuterated internal standards for most compounds, the performance of the method was not influenced by matrix effects. A preliminary account of OF samples collected at the roadside showed the presence of amphetamine, cocaine, codeine, Delta-9-tetrahydrocannabinol, tramadol, and zopiclone. The UPLC-MS/MS method makes it possible to detect all 29 analytes in 1 chromatographic run (15 min), including Delta-9-tetrahydrocannabinol and benzoylecgonine, which previously have been difficult to incorporate into multicomponent methods.

  19. Rapid analysis of Aurantii Fructus Immaturus (Zhishi) using paper spray ionization mass spectrometry.

    PubMed

    Liu, Xuemei; Gu, Zhixin; Guo, Yuan; Liu, Jingjing; Ma, Ming; Chen, Bo; Wang, Liping

    2017-04-15

    Paper spray-mass spectrometry (PS-MS) is a rapid, solvent-efficient, and high-throughput analytical method for analyzing complex samples. In this study, a PS-MS method was developed to obtain MS profiles of Aurantii Fructus Immaturus (aka Zhishi in Chinese) in positive and negative ion modes. In combination with multivariate analyses, including principal component analysis and cluster analysis, the PS-MS profiles of 25 batches of Zhishi were discriminated in 25 batches of Citri Reticulatae Pericarpium Viride (aka Qingpi in Chinese; an adulterant of Zhishi). Moreover, a rapid quantitative analysis of synephrine, a prescriptive quality control component of Zhishi listed in the Chinese Pharmacopoeia, was conducted with PS-MS using synephrine-d2 as an internal standard (IS). The linearity range was 1.68-16.8μg/mL (R 2 =0.9985), the limit of quantitation was 0.5μg/mL. Relative standard deviations in the intra- and inter-day precision of the MS were 4.87 and 4.90%, respectively. Compared with HPLC results, there was no significant difference in the quantitation of synephrine. This study demonstrated that the PS-MS method is useful for the rapid discrimination and quality control of Zhishi samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Rapid Diagnosis of Bloodstream Infections with PCR Followed by Mass Spectrometry

    PubMed Central

    Jordana-Lluch, Elena; Carolan, Heather E.; Giménez, Montserrat; Sampath, Rangarajan; Ecker, David J.; Quesada, M. Dolores; Mòdol, Josep M.; Arméstar, Fernando; Blyn, Lawrence B.; Cummins, Lendell L.; Ausina, Vicente; Martró, Elisa

    2013-01-01

    Achieving a rapid microbiological diagnosis is crucial for decreasing morbidity and mortality of patients with a bloodstream infection, as it leads to the administration of an appropriate empiric antimicrobial therapy. Molecular methods may offer a rapid alternative to conventional microbiological diagnosis involving blood culture. In this study, the performance of a new technology that uses broad-spectrum PCR coupled with mass spectrometry (PCR/ESI-MS) was evaluated for the detection of microorganisms directly from whole blood. A total of 247 whole blood samples and paired blood cultures were prospectively obtained from 175 patients with a suspicion of sepsis. Both sample types were analyzed using the PCR/ESI-MS technology, and the results were compared with those obtained by conventional identification methods. The overall agreement between conventional methods and PCR/ESI-MS performed in blood culture aliquots was 94.2% with 96.8% sensitivity and 98.5% specificity for the molecular method. When comparing conventional methods with PCR/ESI-MS performed in whole blood specimens, the overall agreement was 77.1% with 50% sensitivity and 93.8% specificity for the molecular method. Interestingly, the PCR/ESI-MS technology led to the additional identification of 13 pathogens that were not found by conventional methods. Using the PCR/ESI-MS technology the microbiological diagnosis of bloodstream infections could be anticipated in about half of the patients in our setting, including a small but significant proportion of patients newly diagnosed. Thus, this promising technology could be very useful for the rapid diagnosis of sepsis in combination with traditional methods. PMID:23626775

  1. Simultaneous Speciation of Arsenic, Selenium, and Chromium by HPLC-ICP-MS

    USGS Publications Warehouse

    Wolf, Ruth E.; Morman, Suzette A.; Morrison, Jean M.; Lamothe, Paul J.

    2008-01-01

    An adaptation of an analytical method developed for chromium speciation has been utilized for the simultaneous determination of As(III), As(V), Se(IV), Se(VI), Cr(III), and Cr(VI) species using high performance liquid chromatography (HPLC) separation with ICP-MS detection. Reduction of interferences for the determination of As, Se, and Cr by ICP-MS is a major consideration for this method. Toward this end, a Dynamic Reaction Cell (DRC) ICP-MS system was used to detect the species eluted from the chromatographic column. A variety of reaction cell gases and conditions may be utilized, and the advantages and limitations of the gases tested to date will be presented and discussed. The separation and detection of the As, Se, and Cr species of interest can be achieved using the same chromatographic conditions in less than 2 minutes by complexing the Cr(III) with EDTA prior to injection on the HPLC column. Practical aspects of simultaneous speciation analysis will be presented and discussed, including issues with HPLC sample vial contamination, standard and sample contamination, species stability, and considerations regarding sample collection and preservation methods. The results of testing to determine the method's robustness to common concomitant element and anion effects will also be discussed. Finally, results will be presented using the method for the analysis of a variety of environmental and geological samples including waters, soil leachates and simulated bio-fluid leachates.

  2. Use of a Deuterated Internal Standard with Pyrolysis-GC/MS Dimeric Marker Analysis to Quantify Tire Tread Particles in the Environment

    PubMed Central

    Unice, Kenneth M.; Kreider, Marisa L.; Panko, Julie M.

    2012-01-01

    Pyrolysis(pyr)-GC/MS analysis of characteristic thermal decomposition fragments has been previously used for qualitative fingerprinting of organic sources in environmental samples. A quantitative pyr-GC/MS method based on characteristic tire polymer pyrolysis products was developed for tread particle quantification in environmental matrices including soil, sediment, and air. The feasibility of quantitative pyr-GC/MS analysis of tread was confirmed in a method evaluation study using artificial soil spiked with known amounts of cryogenically generated tread. Tread concentration determined by blinded analyses was highly correlated (r2 ≥ 0.88) with the known tread spike concentration. Two critical refinements to the initial pyrolysis protocol were identified including use of an internal standard and quantification by the dimeric markers vinylcyclohexene and dipentene, which have good specificity for rubber polymer with no other appreciable environmental sources. A novel use of deuterated internal standards of similar polymeric structure was developed to correct the variable analyte recovery caused by sample size, matrix effects, and ion source variability. The resultant quantitative pyr-GC/MS protocol is reliable and transferable between laboratories. PMID:23202830

  3. A level set method for multiple sclerosis lesion segmentation.

    PubMed

    Zhao, Yue; Guo, Shuxu; Luo, Min; Shi, Xue; Bilello, Michel; Zhang, Shaoxiang; Li, Chunming

    2018-06-01

    In this paper, we present a level set method for multiple sclerosis (MS) lesion segmentation from FLAIR images in the presence of intensity inhomogeneities. We use a three-phase level set formulation of segmentation and bias field estimation to segment MS lesions and normal tissue region (including GM and WM) and CSF and the background from FLAIR images. To save computational load, we derive a two-phase formulation from the original multi-phase level set formulation to segment the MS lesions and normal tissue regions. The derived method inherits the desirable ability to precisely locate object boundaries of the original level set method, which simultaneously performs segmentation and estimation of the bias field to deal with intensity inhomogeneity. Experimental results demonstrate the advantages of our method over other state-of-the-art methods in terms of segmentation accuracy. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Multivariate analysis of progressive thermal desorption coupled gas chromatography-mass spectrometry.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Van Benthem, Mark Hilary; Mowry, Curtis Dale; Kotula, Paul Gabriel

    Thermal decomposition of poly dimethyl siloxane compounds, Sylgard{reg_sign} 184 and 186, were examined using thermal desorption coupled gas chromatography-mass spectrometry (TD/GC-MS) and multivariate analysis. This work describes a method of producing multiway data using a stepped thermal desorption. The technique involves sequentially heating a sample of the material of interest with subsequent analysis in a commercial GC/MS system. The decomposition chromatograms were analyzed using multivariate analysis tools including principal component analysis (PCA), factor rotation employing the varimax criterion, and multivariate curve resolution. The results of the analysis show seven components related to offgassing of various fractions of siloxanes that varymore » as a function of temperature. Thermal desorption coupled with gas chromatography-mass spectrometry (TD/GC-MS) is a powerful analytical technique for analyzing chemical mixtures. It has great potential in numerous analytic areas including materials analysis, sports medicine, in the detection of designer drugs; and biological research for metabolomics. Data analysis is complicated, far from automated and can result in high false positive or false negative rates. We have demonstrated a step-wise TD/GC-MS technique that removes more volatile compounds from a sample before extracting the less volatile compounds. This creates an additional dimension of separation before the GC column, while simultaneously generating three-way data. Sandia's proven multivariate analysis methods, when applied to these data, have several advantages over current commercial options. It also has demonstrated potential for success in finding and enabling identification of trace compounds. Several challenges remain, however, including understanding the sources of noise in the data, outlier detection, improving the data pretreatment and analysis methods, developing a software tool for ease of use by the chemist, and demonstrating our belief that this multivariate analysis will enable superior differentiation capabilities. In addition, noise and system artifacts challenge the analysis of GC-MS data collected on lower cost equipment, ubiquitous in commercial laboratories. This research has the potential to affect many areas of analytical chemistry including materials analysis, medical testing, and environmental surveillance. It could also provide a method to measure adsorption parameters for chemical interactions on various surfaces by measuring desorption as a function of temperature for mixtures. We have presented results of a novel method for examining offgas products of a common PDMS material. Our method involves utilizing a stepped TD/GC-MS data acquisition scheme that may be almost totally automated, coupled with multivariate analysis schemes. This method of data generation and analysis can be applied to a number of materials aging and thermal degradation studies.« less

  5. Liquid chromatography-tandem mass spectrometry characterization of five new leucinostatins produced by Paecilomyces lilacinus CG-189.

    PubMed

    Martinez, Ana Flávia Canovas; Moraes, Luiz Alberto Beraldo

    2015-03-01

    The fungus Paecilomyces lilacinus produces leucinostatins—peptaibiotics that exert a range of biological activities including antimalarial, antiviral, antitumor and phytotoxicity. In this paper, we developed an analytical method employing LC-MS/MS in the precursor ion and product ion scan modes to elucidate five new leucinostatins. Direct Infusion (DI-MS) helped to identify the most abundant leucinostatins: F, D B2, S, A and K. MS/MS analysis using a triple quadrupole operating at different scan modes is a versatile tool to study natural products, especially peptaibiotics. Although DI-MS full-scan analysis is rapid and sensitive, it cannot distinguish between peptide isomers. On the other hand, LC-MS/MS operated in the precursor ion and product ion modes is time consuming, but allows identifying the structure of isomers or isobar in crude extracts.

  6. Advantages of automation in plasma sample preparation prior to HPLC/MS/MS quantification: application to the determination of cilazapril and cilazaprilat in a bioequivalence study.

    PubMed

    Kolocouri, Filomila; Dotsikas, Yannis; Apostolou, Constantinos; Kousoulos, Constantinos; Soumelas, Georgios-Stefanos; Loukas, Yannis L

    2011-01-01

    An HPLC/MS/MS method characterized by complete automation and high throughput was developed for the determination of cilazapril and its active metabolite cilazaprilat in human plasma. All sample preparation and analysis steps were performed by using 2.2 mL 96 deep-well plates, while robotic liquid handling workstations were utilized for all liquid transfer steps, including liquid-liquid extraction. The whole procedure was very fast compared to a manual procedure with vials and no automation. The method also had a very short chromatographic run time of 1.5 min. Sample analysis was performed by RP-HPLC/MS/MS with positive electrospray ionization using multiple reaction monitoring. The calibration curve was linear in the range of 0.500-300 and 0.250-150 ng/mL for cilazapril and cilazaprilat, respectively. The proposed method was fully validated and proved to be selective, accurate, precise, reproducible, and suitable for the determination of cilazapril and cilazaprilat in human plasma. Therefore, it was applied to a bioequivalence study after per os administration of 2.5 mg tablet formulations of cilazapril.

  7. Negative-pressure cavitation extraction for the determination of flavonoids in pigeon pea leaves by liquid chromatography-tandem mass spectrometry.

    PubMed

    Liu, Wei; Fu, Yujie; Zu, Yuangang; Kong, Yu; Zhang, Lin; Zu, Baishi; Efferth, Thomas

    2009-05-01

    A new method, namely negative-pressure cavitation extraction (NPCE), followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) is presented for the extraction and quantification of flavonoids in pigeon pea leaves. This method combines the high efficiency of NPCE and the sensitivity and accuracy of MS/MS. The influential parameters of the NPCE procedure including liquid/solid ratio, extraction time, nitrogen flow and number of extraction cycles were optimized. Under optimized conditions, the efficiency of NPCE for extracting five flavonoids was compared to microwave-assisted extraction (MAE), ultrasonic extraction (USE) and heating reflux extraction (HRE). Additionally, structural disruption to pigeon pea leaves samples with different extraction methods was investigated by scanning electron microscopy. The relative recovery with NPCE was equivalent to or higher than that with USE and obviously higher than those with MAE and HRE which are usually conducted in higher temperatures. Furthermore, because NPCE was performed with nitrogen at room temperature, the degradation and oxidation of analytes were avoided. In addition, the NPCE method was validated in terms of repeatability and reproducibility, relative standard deviation for relative recovery was lower than 5.84 and 8.83%, respectively. The method was also successfully applied for the quantification of five flavonoids in pigeon pea leaves. All these results suggest that the developed NPCE-LC-MS/MS method represents an excellent alternative for the extraction and quantification of flavonoids in other plant materials.

  8. A Collaborative Evaluation of LC-MS/MS Based Methods for BMAA Analysis: Soluble Bound BMAA Found to Be an Important Fraction

    PubMed Central

    Faassen, Elisabeth J.; Antoniou, Maria G.; Beekman-Lukassen, Wendy; Blahova, Lucie; Chernova, Ekaterina; Christophoridis, Christophoros; Combes, Audrey; Edwards, Christine; Fastner, Jutta; Harmsen, Joop; Hiskia, Anastasia; Ilag, Leopold L.; Kaloudis, Triantafyllos; Lopicic, Srdjan; Lürling, Miquel; Mazur-Marzec, Hanna; Meriluoto, Jussi; Porojan, Cristina; Viner-Mozzini, Yehudit; Zguna, Nadezda

    2016-01-01

    Exposure to β-N-methylamino-l-alanine (BMAA) might be linked to the incidence of amyotrophic lateral sclerosis, Alzheimer’s disease and Parkinson’s disease. Analytical chemistry plays a crucial role in determining human BMAA exposure and the associated health risk, but the performance of various analytical methods currently employed is rarely compared. A CYANOCOST initiated workshop was organized aimed at training scientists in BMAA analysis, creating mutual understanding and paving the way towards interlaboratory comparison exercises. During this workshop, we tested different methods (extraction followed by derivatization and liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) analysis, or directly followed by LC-MS/MS analysis) for trueness and intermediate precision. We adapted three workup methods for the underivatized analysis of animal, brain and cyanobacterial samples. Based on recovery of the internal standard D3BMAA, the underivatized methods were accurate (mean recovery 80%) and precise (mean relative standard deviation 10%), except for the cyanobacterium Leptolyngbya. However, total BMAA concentrations in the positive controls (cycad seeds) showed higher variation (relative standard deviation 21%–32%), implying that D3BMAA was not a good indicator for the release of BMAA from bound forms. Significant losses occurred during workup for the derivatized method, resulting in low recovery (<10%). Most BMAA was found in a trichloroacetic acid soluble, bound form and we recommend including this fraction during analysis. PMID:26938542

  9. Classification of multiple sclerosis lesions using adaptive dictionary learning.

    PubMed

    Deshpande, Hrishikesh; Maurel, Pierre; Barillot, Christian

    2015-12-01

    This paper presents a sparse representation and an adaptive dictionary learning based method for automated classification of multiple sclerosis (MS) lesions in magnetic resonance (MR) images. Manual delineation of MS lesions is a time-consuming task, requiring neuroradiology experts to analyze huge volume of MR data. This, in addition to the high intra- and inter-observer variability necessitates the requirement of automated MS lesion classification methods. Among many image representation models and classification methods that can be used for such purpose, we investigate the use of sparse modeling. In the recent years, sparse representation has evolved as a tool in modeling data using a few basis elements of an over-complete dictionary and has found applications in many image processing tasks including classification. We propose a supervised classification approach by learning dictionaries specific to the lesions and individual healthy brain tissues, which include white matter (WM), gray matter (GM) and cerebrospinal fluid (CSF). The size of the dictionaries learned for each class plays a major role in data representation but it is an even more crucial element in the case of competitive classification. Our approach adapts the size of the dictionary for each class, depending on the complexity of the underlying data. The algorithm is validated using 52 multi-sequence MR images acquired from 13 MS patients. The results demonstrate the effectiveness of our approach in MS lesion classification. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Methods in endogenous steroid profiling - A comparison of gas chromatography mass spectrometry (GC-MS) with supercritical fluid chromatography tandem mass spectrometry (SFC-MS/MS).

    PubMed

    Teubel, Juliane; Wüst, Bernhard; Schipke, Carola G; Peters, Oliver; Parr, Maria Kristina

    2018-06-15

    In various fields of endocrinology, the determination of steroid hormones synthesised by the human body plays an important role. Research on central neurosteroids has been intensified within the last years, as they are discussed as biomarkers for various cognitive disorders. Their concentrations in cerebrospinal fluid (CSF) are considered to be regulated independently from peripheral fluids. For that reason, the challenging matrix CSF becomes a very interesting specimen for analysis. Concentrations are expected to be very low and available amount of CSF is limited. Thus, a comprehensive method for very sensitive quantification of a set of analytes as large as possible in one analytical aliquot is desired. However, high structural similarities of the selected panel of 51 steroids and steroid sulfates, including numerous isomers, challenges achievement of chromatographic selectivity. Since decades the analysis of endogenous steroids in various body fluids is mainly performed by gas chromatography (GC) coupled to (tandem) mass spectrometry (MS(/MS)). Due to the structure of the steroids of interest, derivatisation is performed to meet the analytical requirements for GC-MS(/MS). Most of the laboratories use a two-step derivatisation in multi-analyte assays that was already published in the 1980s. However, for some steroids this elaborate procedure yields multiple isomeric derivatives. Thus, some laboratories utilize (ultra) high performance liquid chromatography ((U)HPLC)-MS/MS as alternative but, even UHPLC is not able to separate some of the isomeric pairs. Supercritical fluid chromatography (SFC) as an orthogonal separation technique to GC and (U)HPLC may help to overcome these issues. Within this project the two most promising methods for endogenous steroid profiling were investigated and compared: the "gold standard" GC-MS and the orthogonal separation technique SFC-MS/MS. Different derivatisation procedures for gas chromatographic detection were explored and the formation of multiple derivatives described and confirmed. Taken together, none of the investigated derivatisation procedures provided acceptable results for further method development to meet the requirements of this project. SFC with its unique selectivity was able to overcome these issues and to distinguish all selected steroids, including (pro-)gestagens, androgens, corticoids, estrogens, and steroid sulfates with appropriate selectivity. Valued especially in the separation of enantiomeric analytes, SFC has shown its potential as alternative to GC. The successful separation of 51 steroids and steroid sulfates on different columns is presented to demonstrate the potential of SFC in endogenous steroid profiling. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. Enantiomeric separation and quantification of R/S-amphetamine in urine by ultra-high performance supercritical fluid chromatography tandem mass spectrometry.

    PubMed

    Hegstad, S; Havnen, H; Helland, A; Spigset, O; Frost, J

    2018-03-01

    To distinguish between legal and illegal consumption of amphetamine reliable analytical methods for chiral separation of the R- and S-enantiomers of amphetamine in biological specimens are required. In this regard, supercritical fluid chromatography (SFC) has several potential advantages over liquid chromatography, including rapid separation of enantiomers due to low viscosity and high diffusivity of supercritical carbon dioxide, the main component in the SFC mobile phase. A method for enantiomeric separation and quantification of R- and S-amphetamine in urine was developed and validated using ultra-high performance supercritical fluid chromatography-tandem mass spectrometry (UHPSFC-MS/MS). Sample preparation prior to UHPSFC-MS/MS analysis was a semi-automatic solid phase extraction method. The UHPSFC-MS/MS method used a Chiralpak AD-3 column with a mobile phase consisting of CO 2 and 0.2% cyclohexylamine in 2-propanol. The injection volume was 2 μL and run-time was 6 min. MS/MS detection was performed with positive electrospray ionization and two multiple reaction monitoring transitions (m/z 136.1 > 119.0 and m/z 136.1 > 91.0). The calibration range was 50-10,000 ng/mL for each enantiomer. The between-assay relative standard deviations were in the range of 3.7-7.6%. Recovery was 92-93% and matrix effects ranged from 100 to 104% corrected with internal standard. After development and validation, the method has been successfully implemented in routine use at our laboratory for both separation and quantification of R/S-amphetamine, and has proved to be a reliable and useful tool for distinguishing intake of R- and S-amphetamine in authentic patient samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. Determination of 30 synthetic food additives in soft drinks by HPLC/electrospray ionization-tandem mass spectrometry.

    PubMed

    Gao, Hui; Yang, Minli; Wang, Minglin; Zhao, Yansheng; Cao, Ya; Chu, Xiaogang

    2013-01-01

    A method combining SPE with HPLC/electrospray ionization-MS/MS was developed for simultaneous determination of 30 synthetic food additives, including synthetic colorants, preservatives, and sweeteners in soft drinks. All targets were efficiently separated using the optimized chromatographic and MS conditions and parameters in a single run within 18 min. The LOD of the analytes ranged from 0.01 to 20 microg/kg, and the method was validated with recoveries in the 80.8 to 106.4% range. This multisynthetic additive method was found to be accurate and reliable and will be useful to ensure the safety of food products, such as the labeling and proper use of synthetic food additives in soft drinks.

  13. Development of liquid chromatographic methods for the determination of phytosterols in Standard Reference Materials containing saw palmetto.

    PubMed

    Bedner, Mary; Schantz, Michele M; Sander, Lane C; Sharpless, Katherine E

    2008-05-23

    Liquid chromatographic (LC) methods using atmospheric pressure chemical ionization/mass spectrometric (APCI-MS) detection were developed for the separation and analysis of the phytosterols campesterol, cycloartenol, lupenone, lupeol, beta-sitosterol, and stigmasterol. Brassicasterol and cholesterol were also included for investigation as internal standards. The methods were used to identify and quantify the phytosterols in each of two Serenoa repens (saw palmetto) Standard Reference Materials (SRMs) developed by the National Institute of Standards and Technology (NIST). Values obtained by LC-MS were compared to those obtained using the more traditional approach of gas chromatography with flame ionization detection. This is the first reported use of LC-MS to determine phytosterols in saw palmetto dietary supplement materials.

  14. [Application of MALDI-TOF-MS in gene testing for non-syndromic hearing loss].

    PubMed

    Zeng, Yun; Jiang, Dan; Feng, Da-fei; Jin, Dong-dong; Wu, Xiao-hui; Ding, Yan-li; Zou, Jing

    2013-12-01

    To investigate the feasibility of Matrix-Assisted Laser Desorption-Ionization Time of Flight Mass Spectrometry (MALDI-TOF-MS) , according to the genetic test of non-syndromic hearing loss (NSHL), and check using the direct sequencing. Peripheral blood was collected from 454 NSHL patients. DNA samples were extracted and 20 loci of the four common disease-causing genes were analysed by MALDI-TOF-MS, including GJB2 (35delG, 167delT, 176_191del16, 235delC, 299_300delAT ), GJB3 (538C→T, 547G→A), SLC26A4 (281C→T, 589G→A, IVS7-2A→G, 1174A→T, 1226G→A, 1229C→T, IVS15+5G→A, 1975G→C, 2027T→A, 2162C→T, 2168A→G), and mitochondrial 12S rRNA (1494C→T, 1555A→G). Direct sequencing was also used to analyse the aforementioned 20 loci in order to validate the accuracy of MALDI-TOF-MS. Among the 454 patients, 166 cases (36.56%) of disease-causing mutations were detected, which included 69 cases (21.15%) of GJB2 gene mutation, four cases (0.88%) of GJB3 gene mutation, 64 cases (14.10%) of SLC26A4 gene mutation, and three cases (0.66%) of mitochondrial 12S rRNA gene mutation. Moreover, the results obtained from direct sequencing and MALDI-TOF-MS were consistent, and the results showed that the two methods were consistent. The MALDI-TOF-MS detection method was designed based on the hearing loss-related mutation hotspots seen in the Chinese population, and it has a high detection rate for NSHL related mutations. In comparison to the conventional detection methods, MALDI-TOF-MS has the following advantages: more detection sites, greater coverage, accurate, high throughput and low cost. Therefore, this method is capable of satisfying the needs of clinical detection for hearing impairment and it is suitable for large-scale implementation.

  15. Global metabolic profiling procedures for urine using UPLC-MS.

    PubMed

    Want, Elizabeth J; Wilson, Ian D; Gika, Helen; Theodoridis, Georgios; Plumb, Robert S; Shockcor, John; Holmes, Elaine; Nicholson, Jeremy K

    2010-06-01

    The production of 'global' metabolite profiles involves measuring low molecular-weight metabolites (<1 kDa) in complex biofluids/tissues to study perturbations in response to physiological challenges, toxic insults or disease processes. Information-rich analytical platforms, such as mass spectrometry (MS), are needed. Here we describe the application of ultra-performance liquid chromatography-MS (UPLC-MS) to urinary metabolite profiling, including sample preparation, stability/storage and the selection of chromatographic conditions that balance metabolome coverage, chromatographic resolution and throughput. We discuss quality control and metabolite identification, as well as provide details of multivariate data analysis approaches for analyzing such MS data. Using this protocol, the analysis of a sample set in 96-well plate format, would take ca. 30 h, including 1 h for system setup, 1-2 h for sample preparation, 24 h for UPLC-MS analysis and 1-2 h for initial data processing. The use of UPLC-MS for metabolic profiling in this way is not faster than the conventional HPLC-based methods but, because of improved chromatographic performance, provides superior metabolome coverage.

  16. Quantification of Soluble Sugars and Sugar Alcohols by LC-MS/MS.

    PubMed

    Feil, Regina; Lunn, John Edward

    2018-01-01

    Sugars are simple carbohydrates composed primarily of carbon, hydrogen, and oxygen. They play a central role in metabolism as sources of energy and as building blocks for synthesis of structural and nonstructural polymers. Many different techniques have been used to measure sugars, including refractometry, colorimetric and enzymatic assays, gas chromatography, high-performance liquid chromatography, and nuclear magnetic resonance spectroscopy. In this chapter we describe a method that combines an initial separation of sugars by high-performance anion-exchange chromatography (HPAEC) with detection and quantification by tandem mass spectrometry (MS/MS). This combination of techniques provides exquisite specificity, allowing measurement of a diverse range of high- and low-abundance sugars in biological samples. This method can also be used for isotopomer analysis in stable-isotope labeling experiments to measure metabolic fluxes.

  17. Identification of Eight Synthetic Cannabinoids, Including 5F-AKB48 in Seized Herbal Products Using DART-TOF-MS and LC-QTOF-MS as Nontargeted Screening Methods.

    PubMed

    Moore, Katherine N; Garvin, Demetra; Thomas, Brian F; Grabenauer, Megan

    2017-09-01

    Synthetic cannabinoids are sprayed onto plant material and smoked for their marijuana-like effects. Clandestine manufacturers modify synthetic cannabinoid structures by creating closely related analogs. Forensic laboratories are tasked with detection of these analog compounds, but targeted analytical methods are often thwarted by the structural modifications. Here, direct analysis in real time coupled to accurate mass time-of-flight mass spectrometry (DART-TOF-MS) in combination with liquid chromatography quadruple time-of-flight mass spectrometry (LC-QTOF-MS) are presented as a screening and nontargeted confirmation method, respectively. Methanol extracts of herbal material were run using both methods. Spectral data from four different herbal products were evaluated by comparing fragmentation pattern, accurate mass and retention time to available reference standards. JWH-018, JWH-019, AM2201, JWH-122, 5F-AKB48, AKB48-N-(4-pentenyl) analog, UR144, and XLR11 were identified in the products. Results demonstrate that DART-TOF-MS affords a useful approach for rapid screening of herbal products for the presence and identification of synthetic cannabinoids. © 2017 American Academy of Forensic Sciences.

  18. Improved sensitivity of ochratoxin A analysis in coffee using high-performance liquid chromatography with hybrid triple quadrupole-linear ion trap mass spectrometry (LC-QqQLIT-MS/MS).

    PubMed

    Kokina, Aija; Pugajeva, Iveta; Bartkevics, Vadims

    2016-01-01

    A novel and sensitive method utilising high-performance liquid chromatography coupled to triple quadrupole-linear ion trap mass spectrometry (LC-QqQLIT-MS/MS) was developed in order to analyse the content of ochratoxin A (OTA) in coffee samples. The introduction of the triple-stage MS scanning mode (MS(3)) has been shown to increase greatly sensitivity and selectivity by eliminating the high chromatographic baseline caused by interference of complex coffee matrices. The analysis included the sample preparation procedure involving extraction of OTA using a methanol-water mixture and clean-up by immunoaffinity columns and detection using the MS(3) scanning mode of LC-QqQLIT-MS/MS. The proposed method offered a good linear correlation (r(2) > 0.998), excellent precision (RSD < 2.9%) and recovery (94%). The limit of quantification (LOQ) for coffee beans and espresso beverages was 0.010 and 0.003 µg kg(-1), respectively. The developed procedure was compared with traditional methods employing liquid chromatography coupled to fluorescent and tandem quadrupole detectors in conjunction with QuEChERS and solid-phase extraction. The proposed method was successfully applied to the determination of OTA in 15 samples of coffee beans and in 15 samples of espresso coffee beverages obtained from the Latvian market. OTA was found in 10 samples of coffee beans and in two samples of espresso in the ranges of 0.018-1.80 µg kg(-1) and 0.020-0.440 µg l(-1), respectively. No samples exceeded the maximum permitted level of OTA in the European Union (5.0 µg kg(-1)).

  19. Determination of a selection of synthetic cannabinoids and metabolites in urine by UHPSFC-MS/MS and by UHPLC-MS/MS.

    PubMed

    Berg, Thomas; Kaur, Lakhwinder; Risnes, Anna; Havig, Stine Marie; Karinen, Ritva

    2016-07-01

    Two different analytical techniques, ultra-high performance supercritical fluid chromatography-tandem mass spectrometry (UHPSFC-MS/MS) and reversed phase ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS), were used for the determination of two synthetic cannabinoids and eleven metabolites in urine; AM-2201 N-4-OH-pentyl, AM-2233, JWH-018 N-5-OH-pentyl, JWH-018 N-pentanoic acid, JWH-073 N-4-OH-butyl, JWH-073 N-butanoic acid, JWH-122 N-5-OH-pentyl, MAM-2201, MAM-2201 N-4-OH-pentyl, RCS-4 N-5-OH-pentyl, UR-144 degradant N-pentanoic acid, UR-144 N-4-OH-pentyl, and UR-144 N-pentanoic acid. Sample preparation included a liquid-liquid extraction after deconjugation with ß-glucuronidase. The UHPSFC-MS/MS method used an Acquity UPC(2 TM) BEH column with a mobile phase consisting of CO2 and 0.3% ammonia in methanol, while the UHPLC-MS/MS method used an Acquity UPLC® BEH C18 column with a mobile phase consisting of 5 mM ammonium formate (pH 10.2) and methanol. MS/MS detection was performed with positive electrospray ionization and two multiple reaction monitoring transitions. Deuterated internal standards were used for six of the compounds. Limits of quantification (LOQs) were between 0.04 and 0.4 µg/L. Between-day relative standard deviations at concentrations ≥ LOQ were ≤20%, with biases within ±19%. Recoveries ranged from 40 to 90%. Corrected matrix effects were within 100 ± 10%, except for MAM-2201 with UHPSFC-MS/MS, and for UR-144 N-pentanoic acid and MAM-2201 N-4-OH-pentyl with UHPLC-MS/MS. Elution order obtained by UHPSFC-MS/MS was almost opposite to that obtained by UHPLC-MS/MS, making this instrument setup an interesting combination for screening and confirmation analyses in forensic cases. The UHPLC-MS/MS method has, since August 2014, been successfully used for confirmation of synthetic cannabinoids in urine samples revealing a positive immunoassay screening result. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  20. Optimized approaches for quantification of drug transporters in tissues and cells by MRM proteomics.

    PubMed

    Prasad, Bhagwat; Unadkat, Jashvant D

    2014-07-01

    Drug transporter expression in tissues (in vivo) usually differs from that in cell lines used to measure transporter activity (in vitro). Therefore, quantification of transporter expression in tissues and cell lines is important to develop scaling factor for in vitro to in vivo extrapolation (IVIVE) of transporter-mediated drug disposition. Since traditional immunoquantification methods are semiquantitative, targeted proteomics is now emerging as a superior method to quantify proteins, including membrane transporters. This superiority is derived from the selectivity, precision, accuracy, and speed of analysis by liquid chromatography tandem mass spectrometry (LC-MS/MS) in multiple reaction monitoring (MRM) mode. Moreover, LC-MS/MS proteomics has broader applicability because it does not require selective antibodies for individual proteins. There are a number of recent research and review papers that discuss the use of LC-MS/MS for transporter quantification. Here, we have compiled from the literature various elements of MRM proteomics to provide a comprehensive systematic strategy to quantify drug transporters. This review emphasizes practical aspects and challenges in surrogate peptide selection, peptide qualification, peptide synthesis and characterization, membrane protein isolation, protein digestion, sample preparation, LC-MS/MS parameter optimization, method validation, and sample analysis. In particular, bioinformatic tools used in method development and sample analysis are discussed in detail. Various pre-analytical and analytical sources of variability that should be considered during transporter quantification are highlighted. All these steps are illustrated using P-glycoprotein (P-gp) as a case example. Greater use of quantitative transporter proteomics will lead to a better understanding of the role of drug transporters in drug disposition.

  1. Simultaneous determination of 117 pesticides and 30 mycotoxins in raw coffee, without clean-up, by LC-ESI-MS/MS analysis.

    PubMed

    Reichert, Bárbara; de Kok, André; Pizzutti, Ionara Regina; Scholten, Jos; Cardoso, Carmem Dickow; Spanjer, Martien

    2018-04-03

    This paper describes the optimization and validation of an acetonitrile based method for simultaneous extraction of multiple pesticides and mycotoxins from raw coffee beans followed by LC-ESI-MS/MS determination. Before extraction, the raw coffee samples were milled and then slurried with water. The slurried samples were spiked with two separate standard solutions, one containing 131 pesticides and a second with 35 mycotoxins, which were divided into 3 groups of different relative concentration levels. Optimization of the QuEChERS approach included performance tests with acetonitrile acidified with acetic acid or formic acid, with or without buffer and with or without clean-up of the extracts before LC-ESI-MS/MS analysis. For the clean-up step, seven d-SPE sorbents and their various mixtures were evaluated. After method optimization a complete validation study was carried out to ensure adequate performance of the extraction and chromatographic methods. The samples were spiked at 3 concentrations levels with both mycotoxins and pesticides (with 6 replicates at each level, n = 6) and then submitted to the extraction procedure. Before LC-ESI-MS/MS analysis, the acetonitrile extracts were diluted 2-fold with methanol, in order to improve the chromatographic performance of the early-eluting polar analytes. Calibration standard solutions were prepared in organic solvent and in blank coffee extract at 7 concentration levels and analyzed 6 times each. The method was assessed for accuracy (recovery %), precision (RSD%), selectivity, linearity (r 2 ), limit of quantification (LOQ) and matrix effects (%). Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Spectroscopic and Statistical Techniques for Information Recovery in Metabonomics and Metabolomics

    NASA Astrophysics Data System (ADS)

    Lindon, John C.; Nicholson, Jeremy K.

    2008-07-01

    Methods for generating and interpreting metabolic profiles based on nuclear magnetic resonance (NMR) spectroscopy, mass spectrometry (MS), and chemometric analysis methods are summarized and the relative strengths and weaknesses of NMR and chromatography-coupled MS approaches are discussed. Given that all data sets measured to date only probe subsets of complex metabolic profiles, we describe recent developments for enhanced information recovery from the resulting complex data sets, including integration of NMR- and MS-based metabonomic results and combination of metabonomic data with data from proteomics, transcriptomics, and genomics. We summarize the breadth of applications, highlight some current activities, discuss the issues relating to metabonomics, and identify future trends.

  3. Spectroscopic and statistical techniques for information recovery in metabonomics and metabolomics.

    PubMed

    Lindon, John C; Nicholson, Jeremy K

    2008-01-01

    Methods for generating and interpreting metabolic profiles based on nuclear magnetic resonance (NMR) spectroscopy, mass spectrometry (MS), and chemometric analysis methods are summarized and the relative strengths and weaknesses of NMR and chromatography-coupled MS approaches are discussed. Given that all data sets measured to date only probe subsets of complex metabolic profiles, we describe recent developments for enhanced information recovery from the resulting complex data sets, including integration of NMR- and MS-based metabonomic results and combination of metabonomic data with data from proteomics, transcriptomics, and genomics. We summarize the breadth of applications, highlight some current activities, discuss the issues relating to metabonomics, and identify future trends.

  4. Large-Scale Demonstration of Perchlorate Removal using Weak Base Anion Resin at Well No. 3 in Rialto, California

    DTIC Science & Technology

    2012-12-01

    liter MVSL Mid-Valley Sanitary Landfill NDBA N-Nitrosodi-n-butylamine NDEA N-Nitrosodiethylamine NDMA N-Nitrosodimethylamine NDPA N-Nitrosodi-n...chromatography-mass spectrometry/mass spectrometry (IC-MS/MS). Nitrosamines were analyzed using USEPA Method 521. N-nitrosodimethylamine ( NDMA ) was 2.6...Laboratories using USEPA Method 521. Analytes included NDEA, NDMA , NDBA, NDPA, NMEA, NMOR, NPIP, and NPYR. The reportable limit for each of these

  5. Delayed P100-Like Latencies in Multiple Sclerosis: A Preliminary Investigation Using Visual Evoked Spread Spectrum Analysis

    PubMed Central

    Kiiski, Hanni S. M.; Ní Riada, Sinéad; Lalor, Edmund C.; Gonçalves, Nuno R.; Nolan, Hugh; Whelan, Robert; Lonergan, Róisín; Kelly, Siobhán; O'Brien, Marie Claire; Kinsella, Katie; Bramham, Jessica; Burke, Teresa; Ó Donnchadha, Seán; Hutchinson, Michael; Tubridy, Niall; Reilly, Richard B.

    2016-01-01

    Conduction along the optic nerve is often slowed in multiple sclerosis (MS). This is typically assessed by measuring the latency of the P100 component of the Visual Evoked Potential (VEP) using electroencephalography. The Visual Evoked Spread Spectrum Analysis (VESPA) method, which involves modulating the contrast of a continuous visual stimulus over time, can produce a visually evoked response analogous to the P100 but with a higher signal-to-noise ratio and potentially higher sensitivity to individual differences in comparison to the VEP. The main objective of the study was to conduct a preliminary investigation into the utility of the VESPA method for probing and monitoring visual dysfunction in multiple sclerosis. The latencies and amplitudes of the P100-like VESPA component were compared between healthy controls and multiple sclerosis patients, and multiple sclerosis subgroups. The P100-like VESPA component activations were examined at baseline and over a 3-year period. The study included 43 multiple sclerosis patients (23 relapsing-remitting MS, 20 secondary-progressive MS) and 42 healthy controls who completed the VESPA at baseline. The follow-up sessions were conducted 12 months after baseline with 24 MS patients (15 relapsing-remitting MS, 9 secondary-progressive MS) and 23 controls, and again at 24 months post-baseline with 19 MS patients (13 relapsing-remitting MS, 6 secondary-progressive MS) and 14 controls. The results showed P100-like VESPA latencies to be delayed in multiple sclerosis compared to healthy controls over the 24-month period. Secondary-progressive MS patients had most pronounced delay in P100-like VESPA latency relative to relapsing-remitting MS and controls. There were no longitudinal P100-like VESPA response differences. These findings suggest that the VESPA method is a reproducible electrophysiological method that may have potential utility in the assessment of visual dysfunction in multiple sclerosis. PMID:26726800

  6. Simultaneous determination of antidementia drugs in human plasma: procedure transfer from HPLC-MS to UPLC-MS/MS.

    PubMed

    Noetzli, Muriel; Ansermot, Nicolas; Dobrinas, Maria; Eap, Chin B

    2012-05-01

    A previously developed high performance liquid chromatography mass spectrometry (HPLC-MS) procedure for the simultaneous determination of antidementia drugs, including donepezil, galantamine, memantine, rivastigmine and its metabolite NAP 226-90, was transferred to an ultra performance liquid chromatography system coupled to a tandem mass spectrometer (UPLC-MS/MS). The drugs and their internal standards ([(2)H(7)]-donepezil, [(13)C,(2)H(3)]-galantamine, [(13)C(2),(2)H(6)]-memantine, [(2)H(6)]-rivastigmine) were extracted from 250 μL human plasma by protein precipitation with acetonitrile. Chromatographic separation was achieved on a reverse phase column (BEH C18 2.1 mm × 50 mm; 1.7 μm) with a gradient elution of an ammonium acetate buffer at pH 9.3 and acetonitrile at a flow rate of 0.4 mL/min and an overall run time of 4.5 min. The analytes were detected on a tandem quadrupole mass spectrometer operated in positive electrospray ionization mode, and quantification was performed using multiple reaction monitoring. The method was validated according to the recommendations of international guidelines over a calibration range of 1-300 ng/mL for donepezil, galantamine and memantine, and 0.2-50 ng/mL for rivastimgine and NAP 226-90. The trueness (86-108%), repeatability (0.8-8.3%), intermediate precision (2.3-10.9%) and selectivity of the method were found to be satisfactory. Matrix effects variability was inferior to 15% for the analytes and inferior to 5% after correction by internal standards. A method comparison was performed with patients' samples showing similar results between the HPLC-MS and UPLC-MS/MS procedures. Thus, this validated UPLC-MS/MS method allows to reduce the required amount of plasma, to use a simplified sample preparation, and to obtain a higher sensitivity and specificity with a much shortened run-time. Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Ecological risk assessment in legislation on contaminated soil in The Netherlands.

    PubMed

    Boekhold, Alexandra E

    2008-12-01

    Recently the Dutch soil policy was revised including new rules for the relocation of contaminated soil and dredged soil material. With these rules, new methods for ecotoxicological risk assessment were implemented. One of the new methods is the assessment of the local toxic pressure of mixtures, also known as the ms-PAF- method, based on the Species Sensitivity Distribution concept. The ms-PAF method is applied for risk assessment of spreading of dredged soil material on adjacent land. Its application will possibly be extended to the derivation of local soil quality standards relevant in the context of soil relocation. The application of the local toxic pressure will probably increase the reuse of contaminated soil and dredged soil material and hence will reduce the amounts considered to be unfit for use. With this method, local ecological risk limits are derived using pore water concentrations and effects on water organisms. Pore water concentrations are subsequently transferred to total soil concentrations using empirical relationships. The methodology does not impose upper limits for total soil concentrations. In soils with a high sorption capacity, total soil concentrations that are considered to be acceptable may be several times higher than the current Dutch intervention values. The possible introduction of the ms-PAF method will open the door to local soil relocation with soils containing large amounts of (semi-permanently soil bound) contaminants. Since the ms-PAF method is not yet properly validated, the lack of evidence of ecological effects using models like the ms-PAF method cannot be regarded as an indication for the absence of effects in reality. The Dutch soil quality decree would gain environmental ambition when the ms-PAF method was combined with a realistic upper limit on total soil concentrations. This would prevent contamination of land by means of soil relocation.

  8. Data Dependent Peak Model Based Spectrum Deconvolution for Analysis of High Resolution LC-MS Data

    PubMed Central

    2015-01-01

    A data dependent peak model (DDPM) based spectrum deconvolution method was developed for analysis of high resolution LC-MS data. To construct the selected ion chromatogram (XIC), a clustering method, the density based spatial clustering of applications with noise (DBSCAN), is applied to all m/z values of an LC-MS data set to group the m/z values into each XIC. The DBSCAN constructs XICs without the need for a user defined m/z variation window. After the XIC construction, the peaks of molecular ions in each XIC are detected using both the first and the second derivative tests, followed by an optimized chromatographic peak model selection method for peak deconvolution. A total of six chromatographic peak models are considered, including Gaussian, log-normal, Poisson, gamma, exponentially modified Gaussian, and hybrid of exponential and Gaussian models. The abundant nonoverlapping peaks are chosen to find the optimal peak models that are both data- and retention-time-dependent. Analysis of 18 spiked-in LC-MS data demonstrates that the proposed DDPM spectrum deconvolution method outperforms the traditional method. On average, the DDPM approach not only detected 58 more chromatographic peaks from each of the testing LC-MS data but also improved the retention time and peak area 3% and 6%, respectively. PMID:24533635

  9. Systematic assessment of survey scan and MS2-based abundance strategies for label-free quantitative proteomics using high-resolution MS data.

    PubMed

    Tu, Chengjian; Li, Jun; Sheng, Quanhu; Zhang, Ming; Qu, Jun

    2014-04-04

    Survey-scan-based label-free method have shown no compelling benefit over fragment ion (MS2)-based approaches when low-resolution mass spectrometry (MS) was used, the growing prevalence of high-resolution analyzers may have changed the game. This necessitates an updated, comparative investigation of these approaches for data acquired by high-resolution MS. Here, we compared survey scan-based (ion current, IC) and MS2-based abundance features including spectral-count (SpC) and MS2 total-ion-current (MS2-TIC), for quantitative analysis using various high-resolution LC/MS data sets. Key discoveries include: (i) study with seven different biological data sets revealed only IC achieved high reproducibility for lower-abundance proteins; (ii) evaluation with 5-replicate analyses of a yeast sample showed IC provided much higher quantitative precision and lower missing data; (iii) IC, SpC, and MS2-TIC all showed good quantitative linearity (R(2) > 0.99) over a >1000-fold concentration range; (iv) both MS2-TIC and IC showed good linear response to various protein loading amounts but not SpC; (v) quantification using a well-characterized CPTAC data set showed that IC exhibited markedly higher quantitative accuracy, higher sensitivity, and lower false-positives/false-negatives than both SpC and MS2-TIC. Therefore, IC achieved an overall superior performance than the MS2-based strategies in terms of reproducibility, missing data, quantitative dynamic range, quantitative accuracy, and biomarker discovery.

  10. Systematic Assessment of Survey Scan and MS2-Based Abundance Strategies for Label-Free Quantitative Proteomics Using High-Resolution MS Data

    PubMed Central

    2015-01-01

    Survey-scan-based label-free method have shown no compelling benefit over fragment ion (MS2)-based approaches when low-resolution mass spectrometry (MS) was used, the growing prevalence of high-resolution analyzers may have changed the game. This necessitates an updated, comparative investigation of these approaches for data acquired by high-resolution MS. Here, we compared survey scan-based (ion current, IC) and MS2-based abundance features including spectral-count (SpC) and MS2 total-ion-current (MS2-TIC), for quantitative analysis using various high-resolution LC/MS data sets. Key discoveries include: (i) study with seven different biological data sets revealed only IC achieved high reproducibility for lower-abundance proteins; (ii) evaluation with 5-replicate analyses of a yeast sample showed IC provided much higher quantitative precision and lower missing data; (iii) IC, SpC, and MS2-TIC all showed good quantitative linearity (R2 > 0.99) over a >1000-fold concentration range; (iv) both MS2-TIC and IC showed good linear response to various protein loading amounts but not SpC; (v) quantification using a well-characterized CPTAC data set showed that IC exhibited markedly higher quantitative accuracy, higher sensitivity, and lower false-positives/false-negatives than both SpC and MS2-TIC. Therefore, IC achieved an overall superior performance than the MS2-based strategies in terms of reproducibility, missing data, quantitative dynamic range, quantitative accuracy, and biomarker discovery. PMID:24635752

  11. A validated UHPLC-MS/MS method to quantify low levels of anabolic-androgenic steroids naturally present in urine of untreated horses.

    PubMed

    Decloedt, Anneleen; Bailly-Chouriberry, Ludovic; Vanden Bussche, Julie; Garcia, Patrice; Popot, Marie-Agnes; Bonnaire, Yves; Vanhaecke, Lynn

    2015-06-01

    Doping control is a main priority for regulatory bodies of both the horse racing industry and the equestrian sports. Urine and blood samples are screened for the presence of hundreds of forbidden substances including anabolic-androgenic steroids (AASs). Based on the suspected endogenous origin of some AASs, with β-boldenone as the most illicit candidate, this study aimed to improve the knowledge of the naturally present AAS in horse urine. To this extent, a novel ultra high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed and validated according to the Association of Official Racing Chemists (AORC) and European Commission (EC) guidelines, proving the power of this new method. Low limits of detection (0.2 ng/mL), good reproducibility (percentage of standard deviation (%RSD) < 10%), high recovery (94.6 to 117.1%), selectivity and specificity, and a linear response (confirmed with R(2) > 0.99 and lack-of-fit analysis) were obtained for all included AASs. With this method, urine samples of 105 guaranteed untreated horses (47 geldings, 53 mares, and 5 stallions serving as a control) were screened for β-boldenone and five related natural steroids: androstadienedione (ADD), androstenedione (AED), alpha-testosterone (αT), beta-testosterone (βT), and progesterone (P). Progesterone, β-testosterone, and α-testosterone were detected in more than half of the horses at low concentrations (<2 ng/mL). Occasionally, not only testosterone and progesterone but also low concentrations of AED, ADD, and boldenone (Bol) were found (0.5-5 ng/mL). Graphical Abstract A sensitive, new and fully validated UHPLC-MS/MS method has been developed that is able to quantify low levels of anabolic-androgenic steroids naturally present in urine of untreated horses (mares and geldings).

  12. A new carbon-based magnetic material for the dispersive solid-phase extraction of UV filters from water samples before liquid chromatography-tandem mass spectrometry analysis.

    PubMed

    Piovesana, Susy; Capriotti, Anna Laura; Cavaliere, Chiara; La Barbera, Giorgia; Samperi, Roberto; Zenezini Chiozzi, Riccardo; Laganà, Aldo

    2017-07-01

    Magnetic solid-phase extraction is one of the most promising new extraction methods for liquid samples before ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) analysis. Several types of materials, including carbonaceous ones, have been prepared for this purpose. In this paper, for the first time, the preparation, characterization, and sorption capability of Fe 3 O 4 -graphitized carbon black (mGCB) composite toward some compounds of environmental interest were investigated. The synthesized mGCB consisted of micrometric GCB particles with 55 m 2  g -1 surface area bearing some carbonyl and hydroxyl functionalities and the surface partially decorated by Fe 3 O 4 microparticles. The prepared mGCB was firstly tested as an adsorbent for the extraction from surface water of 50 pollutants, including estrogens, perfluoroalkyl compounds, UV filters, and quinolones. The material showed good affinity to many of the tested compounds, except carboxylates and glucoronates; however, some compounds were difficult to desorb. Ten UV filters belonging to the chemical classes of benzophenones and p-aminobenzoates were selected, and parameters were optimized for the extraction of these compounds from surface water before UHPLC-MS/MS determination. Then, the method was validated in terms of linearity, trueness, intra-laboratory precision, and detection and quantification limits. In summary, the method performance (trueness, expressed as analytical recovery, 85-114%; RSD 5-15%) appears suitable for the determination of the selected compounds at the level of 10-100 ng L -1 , with detection limits in the range of 1-5 ng L -1 . Finally, the new method was compared with a published one, based on conventional solid-phase extraction with GCB, showing similar performance in real sample analysis. Graphical Abstract Workflow of the analytical method based on magnetic solid-phase extraction followed by LC-MS/MS determination.

  13. LC/MS/MS Bioanalysis of Protein-Drug Conjugates-The Importance of Incorporating Succinimide Hydrolysis Products.

    PubMed

    Shi, Chuan; Goldberg, Shalom; Lin, Tricia; Dudkin, Vadim; Widdison, Wayne; Harris, Luke; Wilhelm, Sharon; Jmeian, Yazen; Davis, Darryl; O'Neil, Karyn; Weng, Naidong; Jian, Wenying

    2018-04-17

    Bioanalysis of antibody-drug conjugates (ADCs) is challenging due to the complex, heterogeneous nature of their structures and their complicated catabolism. To fully describe the pharmacokinetics (PK) of an ADC, several analytes are commonly quantified, including total antibody, conjugate, and payload. Among them, conjugate is the most challenging to measure, because it requires detection of both small and large molecules as one entity. Existing approaches to quantify the conjugated species of ADCs involve a ligand binding assay (LBA) for conjugated antibody or hybrid LBA/liquid chromatography/tandem mass spectrometry (LC/MS/MS) for quantitation of conjugated drug. In our current work for a protein-drug conjugate (PDC) using the Centyrin scaffold, a similar concept to ADCs but with smaller protein size, an alternative method to quantify the conjugate by using a surrogate peptide approach, was utilized. The His-tagged proteins were isolated from biological samples using immobilized metal affinity chromatography (IMAC), followed by trypsin digestion. The tryptic peptide containing the linker attached to the payload was used as a surrogate of the conjugate and monitored by LC/MS/MS analysis. During method development and its application, we found that hydrolysis of the succinimide ring of the linker was ubiquitous, taking place at many stages during the lifetime of the PDC including in the initial drug product, in vivo in circulation in the animals, and ex vivo during the trypsin digestion step of the sample preparation. We have shown that hydrolysis during trypsin digestion is concentration-independent and consistent during the work flow-therefore, having no impact on assay performance. However, for samples that have undergone extensive hydrolysis prior to trypsin digestion, significant bias could be introduced if only the non-hydrolyzed form is considered in the quantitation. Therefore, it is important to incorporate succinimide hydrolysis products in the quantitation method in order to provide an accurate estimation of the total conjugate level. More importantly, the LC/MS/MS-based method described here provides a useful tool to quantitatively evaluate succinimide hydrolysis of ADCs in vivo, which has been previously reported to have significant impact on their stability, exposure, and efficacy.

  14. LC-MS guided isolation of ent-kaurane diterpenoids from Nouelia insignis.

    PubMed

    Sun, Chang-Li; Geng, Chang-An; Chen, Xing-Long; Yang, Tong-Hua; Yin, Xiu-Juan; Huang, Xiao-Yan; Peng, Hua; Chen, Ji-Jun

    2016-06-01

    The preliminary LC-MS investigation on the stems of Nouelia insignis manifested the existence of diterpenoids. As a result, 15 ent-kaurane diterpenoids, including 7 new glycosides (nouelosides A-G, 1-7), were isolated under the direction of LC-MS analysis. The new compounds were determined by extensive spectroscopic analysis including HRESIMS, 1D and 2D NMR data and chemical methods. Compounds 6 and 15 with the exo-methylene cyclopentanone functional group exhibited obvious nitric oxide production inhibitory activity with IC50 values of 3.84±0.20 and 3.19±0.25μM. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Differential Mobility Spectrometry-Mass Spectrometry (DMS-MS) in Radiation Biodosimetry: Rapid and High-Throughput Quantitation of Multiple Radiation Biomarkers in Nonhuman Primate Urine.

    PubMed

    Chen, Zhidan; Coy, Stephen L; Pannkuk, Evan L; Laiakis, Evagelia C; Fornace, Albert J; Vouros, Paul

    2018-05-07

    High-throughput methods to assess radiation exposure are a priority due to concerns that include nuclear power accidents, the spread of nuclear weapon capability, and the risk of terrorist attacks. Metabolomics, the assessment of small molecules in an easily accessible sample, is the most recent method to be applied for the identification of biomarkers of the biological radiation response with a useful dose-response profile. Profiling for biomarker identification is frequently done using an LC-MS platform which has limited throughput due to the time-consuming nature of chromatography. We present here a chromatography-free simplified method for quantitative analysis of seven metabolites in urine with radiation dose-response using urine samples provided from the Pannkuk et al. (2015) study of long-term (7-day) radiation response in nonhuman primates (NHP). The stable isotope dilution (SID) analytical method consists of sample preparation by strong cation exchange-solid phase extraction (SCX-SPE) to remove interferences and concentrate the metabolites of interest, followed by differential mobility spectrometry (DMS) ion filtration to select the ion of interest and reduce chemical background, followed by mass spectrometry (overall SID-SPE-DMS-MS). Since no chromatography is used, calibration curves were prepared rapidly, in under 2 h (including SPE) for six simultaneously analyzed radiation biomarkers. The seventh, creatinine, was measured separately after 2500× dilution. Creatinine plays a dual role, measuring kidney glomerular filtration rate (GFR), and indicating kidney damage at high doses. The current quantitative method using SID-SPE-DMS-MS provides throughput which is 7.5 to 30 times higher than that of LC-MS and provides a path to pre-clinical radiation dose estimation. Graphical Abstract.

  16. Comprehensive screening and quantification of veterinary drugs in milk using UPLC–ToF-MS

    PubMed Central

    Rutgers, P.; Oosterink, E.; Lasaroms, J. J. P.; Peters, R. J. B.; van Rhijn, J. A.; Nielen, M. W. F.

    2008-01-01

    Ultra-performance liquid chromatography combined with time-of-flight mass spectrometry (UPLC–ToF-MS) has been used for screening and quantification of more than 100 veterinary drugs in milk. The veterinary drugs represent different classes including benzimidazoles, macrolides, penicillins, quinolones, sulphonamides, pyrimidines, tetracylines, nitroimidazoles, tranquillizers, ionophores, amphenicols and non-steroidal anti-inflammatory agents (NSAIDs). After protein precipitation, centrifugation and solid-phase extraction (SPE), the extracts were analysed by UPLC–ToF-MS. From the acquired full scan data the drug-specific ions were extracted for construction of the chromatograms and evaluation of the results. The analytical method was validated according to the EU guidelines (2002/657/EC) for a quantitative screening method. At the concentration level of interest (MRL level) the results for repeatability (%RSD < 20% for 86% of the compounds), reproducibility (%RSD < 40% for 96% of the compounds) and the accuracy (80–120% for 88% of the compounds) were satisfactory. Evaluation of the CCβ values and the linearity results demonstrates that the developed method shows adequate sensitivity and linearity to provide quantitative results. Furthermore, the method is accurate enough to differentiate between suspected and negative samples or drug concentrations below or above the MRL. A set of 100 samples of raw milk were screened for residues. No suspected (positive) results were obtained except for the included blind reference sample containing sulphamethazine (88 μg/l) that tested positive for this compound. UPLC–ToF-MS combines high resolution for both LC and MS with high mass accuracy which is very powerful for the multi-compound analysis of veterinary drugs. The technique seems to be powerful enough for the analysis of not only veterinary drugs but also organic contaminants like pesticides, mycotoxins and plant toxins in one single method. PMID:18491081

  17. Differential Mobility Spectrometry-Mass Spectrometry (DMS-MS) in Radiation Biodosimetry: Rapid and High-Throughput Quantitation of Multiple Radiation Biomarkers in Nonhuman Primate Urine

    NASA Astrophysics Data System (ADS)

    Chen, Zhidan; Coy, Stephen L.; Pannkuk, Evan L.; Laiakis, Evagelia C.; Fornace, Albert J.; Vouros, Paul

    2018-05-01

    High-throughput methods to assess radiation exposure are a priority due to concerns that include nuclear power accidents, the spread of nuclear weapon capability, and the risk of terrorist attacks. Metabolomics, the assessment of small molecules in an easily accessible sample, is the most recent method to be applied for the identification of biomarkers of the biological radiation response with a useful dose-response profile. Profiling for biomarker identification is frequently done using an LC-MS platform which has limited throughput due to the time-consuming nature of chromatography. We present here a chromatography-free simplified method for quantitative analysis of seven metabolites in urine with radiation dose-response using urine samples provided from the Pannkuk et al. (2015) study of long-term (7-day) radiation response in nonhuman primates (NHP). The stable isotope dilution (SID) analytical method consists of sample preparation by strong cation exchange-solid phase extraction (SCX-SPE) to remove interferences and concentrate the metabolites of interest, followed by differential mobility spectrometry (DMS) ion filtration to select the ion of interest and reduce chemical background, followed by mass spectrometry (overall SID-SPE-DMS-MS). Since no chromatography is used, calibration curves were prepared rapidly, in under 2 h (including SPE) for six simultaneously analyzed radiation biomarkers. The seventh, creatinine, was measured separately after 2500× dilution. Creatinine plays a dual role, measuring kidney glomerular filtration rate (GFR), and indicating kidney damage at high doses. The current quantitative method using SID-SPE-DMS-MS provides throughput which is 7.5 to 30 times higher than that of LC-MS and provides a path to pre-clinical radiation dose estimation. [Figure not available: see fulltext.

  18. A robust mass spectrometry method for rapid profiling of erythrocyte ghost membrane proteomes.

    PubMed

    Fye, Haddy K S; Mrosso, Paul; Bruce, Lesley; Thézénas, Marie-Laëtitia; Davis, Simon; Fischer, Roman; Rwegasira, Gration L; Makani, Julie; Kessler, Benedikt M

    2018-01-01

    Red blood cell (RBC) physiology is directly linked to many human disorders associated with low tissue oxygen levels or anemia including chronic obstructive pulmonary disease, congenital heart disease, sleep apnea and sickle cell anemia. Parasites such as Plasmodium spp. and phylum Apicomplexa directly target RBCs, and surface molecules within the RBC membrane are critical for pathogen interactions. Proteomics of RBC membrane 'ghost' fractions has therefore been of considerable interest, but protocols described to date are either suboptimal or too extensive to be applicable to a larger set of clinical cohorts. Here, we describe an optimised erythrocyte isolation protocol from blood, tested for various storage conditions and explored using different fractionation conditions for isolating ghost RBC membranes. Liquid chromatography mass spectrometry (LC-MS) analysis on a Q-Exactive Orbitrap instrument was used to profile proteins isolated from the comparative conditions. Data analysis was run on the MASCOT and MaxQuant platforms to assess their scope and diversity. The results obtained demonstrate a robust method for membrane enrichment enabling consistent MS based characterisation of > 900 RBC membrane proteins in single LC-MS/MS analyses. Non-detergent based membrane solubilisation methods using the tissue and supernatant fractions of isolated ghost membranes are shown to offer effective haemoglobin removal as well as diverse recovery including erythrocyte membrane proteins of high and low abundance. The methods described in this manuscript propose a medium to high throughput framework for membrane proteome profiling by LC-MS of potential applicability to larger clinical cohorts in a variety of disease contexts.

  19. Shotgun proteomics of plant plasma membrane and microdomain proteins using nano-LC-MS/MS.

    PubMed

    Takahashi, Daisuke; Li, Bin; Nakayama, Takato; Kawamura, Yukio; Uemura, Matsuo

    2014-01-01

    Shotgun proteomics allows the comprehensive analysis of proteins extracted from plant cells, subcellular organelles, and membranes. Previously, two-dimensional gel electrophoresis-based proteomics was used for mass spectrometric analysis of plasma membrane proteins. In order to get comprehensive proteome profiles of the plasma membrane including highly hydrophobic proteins with a number of transmembrane domains, a mass spectrometry-based shotgun proteomics method using nano-LC-MS/MS for proteins from the plasma membrane proteins and plasma membrane microdomain fraction is described. The results obtained are easily applicable to label-free protein semiquantification.

  20. Methods of Analysis - Determination of Pyrethroid Insecticides in Water and Sediment Using Gas Chromatography/Mass Spectrometry

    USGS Publications Warehouse

    Hladik, Michelle; Smalling, Kelly L.; Kuivila, Kathryn

    2009-01-01

    A method for the determination of 14 pyrethroid insecticides in environmental water and sediment samples is described. The method was developed by the U.S. Geological Survey in response to increasing concern over the effects of pyrethroids on aquatic organisms. The pyrethroids included in this method are ones that are applied to many agricultural and urban areas. Filtered water samples are extracted for pyrethroids using solid-phase extraction (SPE) with no additional cleanup steps. Sediment and soil samples are extracted using a microwave-assisted extraction system, and the pyrethroids of interest are separated from co-extracted matrix interferences by passing the extracts through stacked graphitized carbon and alumina SPE cartridges, along with the use of high-performance liquid chromatography and gel-permeation chromatography (HPLC/GPC). Quantification of the pyrethroids from the extracted water and sediment samples is done using gas chromatography with mass spectrometry (GC/MS) or gas chromatography with tandem mass spectrometry (GC/MS/MS). Recoveries in test water samples fortified at 10 ng/L ranged from 83 to 107 percent, and recoveries in test sediment samples fortified at 10 ug/kg ranged from 82 to 101 percent; relative standard deviations ranged from 5 to 9 percent in the water samples and 3 to 9 percent in the sediment samples. Method detection limits (MDLs), calculated using U.S. Environmental Protection Agency procedures (40 CFR 136, Appendix B), in water ranged from 2.0 to 6.0 ng/L using GC/MS and 0.5 to 1.0 ng/L using GC/MS/MS. For sediment, the MDLs ranged from 1.0 to 2.6 ug/kg dry weight using GC/MS and 0.2 to 0.5 ug/kg dry weight using GC/MS/MS. The matrix-spike recoveries for each compound, when averaged for 12 environmental water samples, ranged from 84 to 96 percent, and when averaged for 27 environmental sediment samples, ranged from 88 to 100 percent.

  1. Development of a multi-residue method for the determination of human and veterinary pharmaceuticals and some of their metabolites in aqueous environmental matrices by SPE-UHPLC-MS/MS.

    PubMed

    Paíga, P; Santos, L H M L M; Delerue-Matos, C

    2017-02-20

    The aim of the present work was to develop and validate a multi-residue method for the analysis of 33 human and veterinary pharmaceuticals (non-steroidal anti-inflammatory drugs (NSAIDs)/analgesics, antibiotics and psychiatric drugs), including some of their metabolites, in several aqueous environmental matrices: drinking water, surface water and wastewaters. The method is based on solid phase extraction (SPE) followed by ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) and it was validated for different aqueous matrices, namely bottled water, tap water, seawater, river water and wastewaters, showing recoveries between 50% and 112% for the majority of the target analytes. The developed analytical methodology allowed method detection limits in the low nanograms per liter level. Method intra- and inter-day precision was under 8% and 11%, respectively, expressed as relative standard deviation. The developed method was applied to the analysis of drinking water (bottled and tap water), surface waters (seawater and river water) and wastewaters (wastewater treatment plant (WWTP) influent and effluent). Due to the selectivity and sensitivity of the optimized method, it was possible to detect pharmaceuticals in all the aqueous environmental matrices considered, including in bottled water at concentrations up to 31ngL -1 (salicylic acid). In general, non-steroidal anti-inflammatory drugs/analgesics was the therapeutic group most frequently detected, with the highest concentrations found in wastewaters (acetaminophen and the metabolite carboxyibuprofen at levels up to 615 and 120μgL -1 , respectively). Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Eco-friendly LC-MS/MS method for analysis of multi-class micropollutants in tap, fountain, and well water from northern Portugal.

    PubMed

    Barbosa, Marta O; Ribeiro, Ana R; Pereira, Manuel F R; Silva, Adrián M T

    2016-11-01

    Organic micropollutants present in drinking water (DW) may cause adverse effects for public health, and so reliable analytical methods are required to detect these pollutants at trace levels in DW. This work describes the first green analytical methodology for multi-class determination of 21 pollutants in DW: seven pesticides, an industrial compound, 12 pharmaceuticals, and a metabolite (some included in Directive 2013/39/EU or Decision 2015/495/EU). A solid-phase extraction procedure followed by ultra-high-performance liquid chromatography coupled to tandem mass spectrometry (offline SPE-UHPLC-MS/MS) method was optimized using eco-friendly solvents, achieving detection limits below 0.20 ng L -1 . The validated analytical method was successfully applied to DW samples from different sources (tap, fountain, and well waters) from different locations in the north of Portugal, as well as before and after bench-scale UV and ozonation experiments in spiked tap water samples. Thirteen compounds were detected, many of them not regulated yet, in the following order of frequency: diclofenac > norfluoxetine > atrazine > simazine > warfarin > metoprolol > alachlor > chlorfenvinphos > trimethoprim > clarithromycin ≈ carbamazepine ≈ PFOS > citalopram. Hazard quotients were also estimated for the quantified substances and suggested no adverse effects to humans. Graphical Abstract Occurrence and removal of multi-class micropollutants in drinking water, analyzed by an eco-friendly LC-MS/MS method.

  3. Preliminary study of urine metabolism in type two diabetic patients based on GC-MS

    PubMed Central

    Zhang, Ning; Geng, Fang; Hu, Zhong-Hua; Liu, Bin; Wang, Ye-Qiu; Liu, Jun-Cen; Qi, Yong-Hua; Li, Li-Jing

    2016-01-01

    Objective: Comparative study of type 2 diabetes and healthy controls by metabolomics methods to explore the pathogenesis of Type II diabetes. Methods: Gas chromatography - mass spectrometry (GC-MS) with a variety of multivariate statistical analysis methods to the healthy control group 58 cases, 68 cases of Type II diabetes group were analyzed. Chromatographic conditions: DB-5MS column; the carrier gas He; flow rate of 1 mL·min-1, the injection volume 1 uL; split ratio is 100: 1. MS conditions: electron impact (EI) ion source, an auxiliary temperature of 280°C, the ion source 230°C, quadrupole 150°C; mass scan range 30~600 mAu. Results: Established analytical method based on urine metabolomics GC-MS of Type II diabetes, determine the urine succinic acid, L-leucine, L-isoleucine, tyrosine, slanine, acetoace acid, mannose, L-isoleucine, L-threonine, Phenylalanine, fructose, D-glucose, palmi acid, oleic acid and arachidonic acid were significantly were significantly changed. Conclusion: Based on metabolomics of GC-MS detection and analysis metabolites can be found differences between type 2 diabetes and healthy control group, PCA diagram can effectively distinguish Type II diabetes and healthy control group, with load diagrams and PLS-DA VIP value metabolite screening, the resulting differences in metabolic pathways involved metabolites, including amino acid metabolism, lipid metabolism, glucose metabolism and energy metabolism. PMID:27508010

  4. Application of survival analysis methodology to the quantitative analysis of LC-MS proteomics data.

    PubMed

    Tekwe, Carmen D; Carroll, Raymond J; Dabney, Alan R

    2012-08-01

    Protein abundance in quantitative proteomics is often based on observed spectral features derived from liquid chromatography mass spectrometry (LC-MS) or LC-MS/MS experiments. Peak intensities are largely non-normal in distribution. Furthermore, LC-MS-based proteomics data frequently have large proportions of missing peak intensities due to censoring mechanisms on low-abundance spectral features. Recognizing that the observed peak intensities detected with the LC-MS method are all positive, skewed and often left-censored, we propose using survival methodology to carry out differential expression analysis of proteins. Various standard statistical techniques including non-parametric tests such as the Kolmogorov-Smirnov and Wilcoxon-Mann-Whitney rank sum tests, and the parametric survival model and accelerated failure time-model with log-normal, log-logistic and Weibull distributions were used to detect any differentially expressed proteins. The statistical operating characteristics of each method are explored using both real and simulated datasets. Survival methods generally have greater statistical power than standard differential expression methods when the proportion of missing protein level data is 5% or more. In particular, the AFT models we consider consistently achieve greater statistical power than standard testing procedures, with the discrepancy widening with increasing missingness in the proportions. The testing procedures discussed in this article can all be performed using readily available software such as R. The R codes are provided as supplemental materials. ctekwe@stat.tamu.edu.

  5. Analytical method for fast screening and confirmation of multi-class veterinary drug residues in fish and shrimp by LC-MS/MS.

    PubMed

    Kim, Junghyun; Suh, Joon Hyuk; Cho, Hyun-Deok; Kang, Wonjae; Choi, Yong Seok; Han, Sang Beom

    2016-01-01

    A multi-class, multi-residue analytical method based on LC-MS/MS detection was developed for the screening and confirmation of 28 veterinary drug and metabolite residues in flatfish, shrimp and eel. The chosen veterinary drugs are prohibited or unauthorised compounds in Korea, which were categorised into various chemical classes including nitroimidazoles, benzimidazoles, sulfones, quinolones, macrolides, phenothiazines, pyrethroids and others. To achieve fast and simultaneous extraction of various analytes, a simple and generic liquid extraction procedure using EDTA-ammonium acetate buffer and acetonitrile, without further clean-up steps, was applied to sample preparation. The final extracts were analysed by ultra-high-performance liquid chromatography coupled with tandem mass spectrometry (UHPLC-MS/MS). The method was validated for each compound in each matrix at three different concentrations (5, 10 and 20 ng g(-1)) in accordance with Codex guidelines (CAC/GL 71-2009). For most compounds, the recoveries were in the range of 60-110%, and precision, expressed as the relative standard deviation (RSD), was in the range of 5-15%. The detection capabilities (CCβs) were below or equal to 5 ng g(-1), which indicates that the developed method is sufficient to detect illegal fishery products containing the target compounds above the residue limit (10 ng g(-1)) of the new regulatory system (Positive List System - PLS).

  6. Psychiatry Morbidity and Mortality Rounds: Implementation and Impact

    ERIC Educational Resources Information Center

    Goldman, Stuart; Demaso, David R.; Kemler, Beth

    2009-01-01

    Objective: This study assessed the implementation of psychiatry morbidity and mortality rounds (M&Ms) on the clinical and educational practice in a children's hospital. Methods: Attendees to monthly M&Ms between July 2005 and May 2007 included staff and trainees from psychiatry, psychology, nursing, and social work. Cases were selected based on a…

  7. Detection and characterization of a new metabolite of 17alpha-methyltestosterone.

    PubMed

    Pozo, Oscar J; Van Eenoo, Peter; Deventer, Koen; Lootens, Leen; Van Thuyne, Wim; Parr, Maria K; Schänzer, Wilhelm; Sancho, Juan V; Hernández, Felix; Meuleman, Philip; Leroux-Roels, Geert; Delbeke, Frans T

    2009-11-01

    The misuse of the anabolic steroid methyltestosterone is currently routinely monitored in doping control laboratories by gas chromatography-mass spectrometry (GC-MS) of two of its metabolites: 17alpha-methyl-5beta-androstane-3alpha,17beta-diol and 17alpha-methyl-5alpha-androstane-3alpha,17beta-diol. Because of the absence of any easy ionizable moiety, these metabolites are poorly detectable using liquid chromatography-tandem mass spectrometry (LC-MS/MS) with electrospray ionization (ESI). In this study, the metabolism of methyltestosterone has been reinvestigated by the use of a precursor ion scan method in LC-ESI-MS/MS. Two metabolites have been detected using this method. Both compounds have been confirmed in postadministration urine samples of an urokinase plasminogen activator-severe combined immunodeficiency (uPA-SCID) mouse with humanized liver and were characterized by LC-MS/MS and GC-MS using both quadrupole and time of flight analyzers. From the detailed study of the fragmentation, these metabolites were proposed to be epimethyltestosterone and a dehydrogenated compound. Epimethyltestosterone has previously been described as a minor metabolite, whereas the occurrence of the oxidized metabolite has not been reported. Comparison with the synthesized reference revealed that the structure of the dehydrogenated metabolite is 6-ene-epimethyltestosterone. A selected reaction monitoring method including three transitions for each metabolite has been developed and applied to samples from an excretion study and to samples declared positive after GC-MS analysis. 6-Ene-epimethyltestosterone was found in all samples, showing its applicability in the detection of methyltestosterone misuse.

  8. Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry for rapid identification of fungal rhinosinusitis pathogens.

    PubMed

    Huang, Yanfei; Wang, Jinglin; Zhang, Mingxin; Zhu, Min; Wang, Mei; Sun, Yufeng; Gu, Haitong; Cao, Jingjing; Li, Xue; Zhang, Shaoya; Lu, Xinxin

    2017-03-01

    Filamentous fungi are among the most important pathogens, causing fungal rhinosinusitis (FRS). Current laboratory diagnosis of FRS pathogens mainly relies on phenotypic identification by culture and microscopic examination, which is time consuming and expertise dependent. Although matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) MS has been employed to identify various fungi, its efficacy in the identification of FRS fungi is less clear. A total of 153 FRS isolates obtained from patients were analysed at the Clinical Laboratory at the Beijing Tongren Hospital affiliated to the Capital Medical University, between January 2014 and December 2015. They were identified by traditional phenotypic methods and Bruker MALDI-TOF MS (Bruker, Biotyper version 3.1), respectively. Discrepancies between the two methods were further validated by sequencing. Among the 153 isolates, 151 had correct species identification using MALDI-TOF MS (Bruker, Biot 3.1, score ≥2.0 or 2.3). MALDI-TOF MS enabled identification of some very closely related species that were indistinguishable by conventional phenotypic methods, including 1/10 Aspergillus versicolor, 3/20 Aspergillus flavus, 2/30 Aspergillus fumigatus and 1/20 Aspergillus terreus, which were misidentified by conventional phenotypic methods as Aspergillus nidulans, Aspergillus oryzae, Aspergillus japonicus and Aspergillus nidulans, respectively. In addition, 2/2 Rhizopus oryzae and 1/1 Rhizopus stolonifer that were identified only to the genus level by the phenotypic method were correctly identified by MALDI-TOF MS. MALDI-TOF MS is a rapid and accurate technique, and could replace the conventional phenotypic method for routine identification of FRS fungi in clinical microbiology laboratories.

  9. Identifying cancer biomarkers by mass spectrometry-based glycomics

    PubMed Central

    Mechref, Yehia; Hu, Yunli; Garcia, Aldo; Hussein, Ahmed

    2013-01-01

    Correlations between aberrant glycosylation and cancer have been established for decades. The major advances in mass spectrometry (MS) and separation science have rapidly advanced detailed characterization of the changes associated with cancer development and progression. Over the past 10 years, many reports have described MS-based glycomic methods directed toward comparing the glycomic profiles of different human specimens collected from disease-free individuals and patients with cancers. Glycomic profiling of glycoproteins isolated from human specimens originating from disease-free individuals and patients with cancers have also been performed. Profiling of native, labeled, and permethylated glycans has been acquired using MALDI-MS and LC-MS. This review focuses on describing, discussing, and evaluating the different glycomic methods employed to characterize and quantify glycomic changes associated with cancers of different organs, including breast, colon, esophagus, liver, ovarian, pancreas, and prostate. PMID:22740464

  10. Ultrahigh-performance liquid chromatography electrospray ionization Q-Orbitrap mass spectrometry for the analysis of 451 pesticide residues in fruits and vegetables: method development and validation.

    PubMed

    Wang, Jian; Chow, Willis; Chang, James; Wong, Jon W

    2014-10-22

    This paper presents an application of ultrahigh-performance liquid chromatography electrospray ionization quadrupole Orbitrap high-resolution mass spectrometry (UHPLC/ESI Q-Orbitrap MS) for the determination of 451 pesticide residues in fruits and vegetables. Pesticides were extracted from samples using the QuEChERS (quick, easy, cheap, effective, rugged, and safe) procedure. UHPLC/ESI Q-Orbitrap MS in full MS scan mode acquired full MS data for quantification, and UHPLC/ESI Q-Orbitrap Full MS/dd-MS(2) (i.e., data-dependent scan mode) obtained product ion spectra for identification. UHPLC/ESI Q-Orbitrap MS quantification was achieved using matrix-matched standard calibration curves along with the use of isotopically labeled standards or a chemical analogue as internal standards to achieve optimal method accuracy. The method performance characteristics include overall recovery, intermediate precision, and measurement uncertainty evaluated according to a nested experimental design. For the 10 matrices studied, 94.5% of the pesticides in fruits and 90.7% in vegetables had recoveries between 81 and 110%; 99.3% of the pesticides in fruits and 99.1% of the pesticides in vegetables had an intermediate precision of ≤20%; and 97.8% of the pesticides in fruits and 96.4% of the pesticides in vegetables showed measurement uncertainty of ≤50%. Overall, the UHPLC/ESI Q-Orbitrap MS demonstrated acceptable performance for the quantification of pesticide residues in fruits and vegetables. The UHPLC/ESI Q-Orbitrap Full MS/dd-MS(2) along with library matching showed great potential for identification and is being investigated further for routine practice.

  11. Assessing direct analysis in real-time-mass spectrometry (DART-MS) for the rapid identification of additives in food packaging.

    PubMed

    Ackerman, L K; Noonan, G O; Begley, T H

    2009-12-01

    The ambient ionization technique direct analysis in real time (DART) was characterized and evaluated for the screening of food packaging for the presence of packaging additives using a benchtop mass spectrometer (MS). Approximate optimum conditions were determined for 13 common food-packaging additives, including plasticizers, anti-oxidants, colorants, grease-proofers, and ultraviolet light stabilizers. Method sensitivity and linearity were evaluated using solutions and characterized polymer samples. Additionally, the response of a model additive (di-ethyl-hexyl-phthalate) was examined across a range of sample positions, DART, and MS conditions (temperature, voltage and helium flow). Under optimal conditions, molecular ion (M+H+) was the major ion for most additives. Additive responses were highly sensitive to sample and DART source orientation, as well as to DART flow rates, temperatures, and MS inlet voltages, respectively. DART-MS response was neither consistently linear nor quantitative in this setting, and sensitivity varied by additive. All additives studied were rapidly identified in multiple food-packaging materials by DART-MS/MS, suggesting this technique can be used to screen food packaging rapidly. However, method sensitivity and quantitation requires further study and improvement.

  12. Mass Spectrometry Parameters Optimization for the 46 Multiclass Pesticides Determination in Strawberries with Gas Chromatography Ion-Trap Tandem Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Fernandes, Virgínia C.; Vera, Jose L.; Domingues, Valentina F.; Silva, Luís M. S.; Mateus, Nuno; Delerue-Matos, Cristina

    2012-12-01

    Multiclass analysis method was optimized in order to analyze pesticides traces by gas chromatography with ion-trap and tandem mass spectrometry (GC-MS/MS). The influence of some analytical parameters on pesticide signal response was explored. Five ion trap mass spectrometry (IT-MS) operating parameters, including isolation time (IT), excitation voltage (EV), excitation time (ET), maximum excitation energy or " q" value (q), and isolation mass window (IMW) were numerically tested in order to maximize the instrument analytical signal response. For this, multiple linear regression was used in data analysis to evaluate the influence of the five parameters on the analytical response in the ion trap mass spectrometer and to predict its response. The assessment of the five parameters based on the regression equations substantially increased the sensitivity of IT-MS/MS in the MS/MS mode. The results obtained show that for most of the pesticides, these parameters have a strong influence on both signal response and detection limit. Using the optimized method, a multiclass pesticide analysis was performed for 46 pesticides in a strawberry matrix. Levels higher than the limit established for strawberries by the European Union were found in some samples.

  13. Structure-based manual screening and automatic networking for systematically exploring sansanmycin analogues using high performance liquid chromatography tandem mass spectroscopy.

    PubMed

    Jiang, Zhi-Bo; Ren, Wei-Cong; Shi, Yuan-Yuan; Li, Xing-Xing; Lei, Xuan; Fan, Jia-Hui; Zhang, Cong; Gu, Ren-Jie; Wang, Li-Fei; Xie, Yun-Ying; Hong, Bin

    2018-05-18

    Sansanmycins (SS), one of several known uridyl peptide antibiotics (UPAs) possessing a unique chemical scaffold, showed a good inhibitory effect on the highly refractory pathogens Pseudomonas aeruginosa and Mycobacterium tuberculosis, especially on the multi-drug resistant M. tuberculosis. This study employed high performance liquid chromatography-mass spectrometry detector (HPLC-MSD) ion trap and LTQ orbitrap tandem mass spectrometry (MS/MS) to explore sansanmycin analogues manually and automatically by re-analysis of the Streptomyces sp. SS fermentation broth. The structure-based manual screening method, based on analysis of the fragmentation pathway of known UPAs and on comparisons of the MS/MS spectra with that of sansanmycin A (SS-A), resulted in identifying twenty sansanmycin analogues, including twelve new structures (1-12). Furthermore, to deeply explore sansanmycin analogues, we utilized a GNPS based molecular networking workflow to re-analyze the HPLC-MS/MS data automatically. As a result, eight more new sansanmycins (13-20) were discovered. Compound 1 was discovered to lose two amino acids of residue 1 (AA 1 ) and (2S, 3S)-N 3 -methyl-2,3-diamino butyric acid (DABA) from the N-terminus, and compounds 6, 11 and 12 were found to contain a 2',3'-dehydrated 4',5'-enamine-3'-deoxyuridyl moiety, which have not been reported before. Interestingly, three trace components with novel 5,6-dihydro-5'-aminouridyl group (16-18) were detected for the first time in the sansanmycin-producing strain. Their structures were primarily determined by detail analysis of the data from MS/MS. Compounds 8 and 10 were further confirmed by nuclear magnetic resonance (NMR) data, which proved the efficiency and accuracy of the method of HPLC-MS/MS for exploration of novel UPAs. Comparing to manual screening, the networking method can provide systematic visualization results. Manual screening and networking method may complement with each other to facilitate the mining of novel UPAs. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. The diverse and expanding role of mass spectrometry in structural and molecular biology.

    PubMed

    Lössl, Philip; van de Waterbeemd, Michiel; Heck, Albert Jr

    2016-12-15

    The emergence of proteomics has led to major technological advances in mass spectrometry (MS). These advancements not only benefitted MS-based high-throughput proteomics but also increased the impact of mass spectrometry on the field of structural and molecular biology. Here, we review how state-of-the-art MS methods, including native MS, top-down protein sequencing, cross-linking-MS, and hydrogen-deuterium exchange-MS, nowadays enable the characterization of biomolecular structures, functions, and interactions. In particular, we focus on the role of mass spectrometry in integrated structural and molecular biology investigations of biological macromolecular complexes and cellular machineries, highlighting work on CRISPR-Cas systems and eukaryotic transcription complexes. © 2016 The Authors. Published under the terms of the CC BY NC ND 4.0 license.

  15. Ultra trace determination of 31 pesticides in water samples by direct injection-rapid resolution liquid chromatography-electrospray tandem mass spectrometry.

    PubMed

    Díaz, Laura; Llorca-Pórcel, Julio; Valor, Ignacio

    2008-08-22

    A liquid chromatography-tandem mass spectrometry (LC-MS/MS)-based method for the detection of pesticides in tap and treated wastewater was developed and validated according to the ISO/IEC 17025:1999. Key features of this method include direct injection of 100 microL of sample, an 11 min separation by means of a rapid resolution liquid chromatography system with a 4.6 mm x 50 mm, 1.8 microm particle size reverse phase column and detection by electrospray ionization (ESI) MS-MS. The limits of detection were below 15 ng L(-1) and correlation coefficients for the calibration curves in the range of 30-2000 ng L(-1) were higher than 0.99. Precision was always below 20% and accuracy was confirmed by external evaluation. The main advantages of this method are direct injection of sample without preparative procedures and low limits of detection that fulfill the requirements established by the current European regulations governing pesticide detection.

  16. Analysis of mexicanolide- and phragmalin-type limonoids from Heynea trijuga using high-performance liquid chromatography/electrospray tandem mass spectrometry.

    PubMed

    Yang, Wei; Fang, Dong-Mei; He, Hong-Ping; Hao, Xiao-Jiang; Wu, Zhi-Jun; Zhang, Guo-Lin

    2013-06-15

    Limonoids, a class of tetranortriterpenoids, exhibit various biological effects, including acting as potent antifeedants and insect growth-regulators against various pests. The analysis of phragmalin- and mexicanolide-type limonoids by collision-induced dissociation tandem mass spectrometry (CID-MS/MS) has not been reported. A high-performance liquid chromatography/electrospray ionization (HPLC/ESI)-MS/MS method was developed to investigate the fragmentation patterns of [M+NH4 ](+) ions for nine reference phragmalin- and mexicanolide-type limonoids. The method was also used in the identification of limonoid compounds in botanic extracts of Heynea trijuga. The losses of side chains and the furan part were the major fragmentation patterns. However, there was variation in the relative abundances of product ions resulting from the same fragmentation pathways. A total of 89 phragmalin- and mexicanolide-type limonoids in botanic extracts of Heynea trijuga were detected and 50 of these compounds were identified or tentatively characterized based on elemental constituents, fragmentation pathways, and the profile of the major product ions of reference compounds. In addition, the isomers could be tentatively distinguished. An HPLC/ESI-MS/MS method was developed and could be used to simultaneously identify and screen phragmalin- and mexicanolide-type limonoids in botanic extracts of Heynea trijuga. Copyright © 2013 John Wiley & Sons, Ltd.

  17. Determination of antibacterial agent tilmicosin in pig plasma by LC/MS/MS and its application to pharmacokinetics.

    PubMed

    Li, Bing; Gong, Shi-Yue; Zhou, Xu-Zheng; Yang, Ya-Jun; Li, Jian-Yong; Wei, Xiao-Juan; Cheng, Fu-Sheng; Niu, Jian-Rong; Liu, Xi-Wang; Zhang, Ji-Yu

    2017-03-01

    A rapid and sensitive high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated to quantify tilmicosin in pig plasma. Plasma samples were prepared by liquid-liquid extraction. Chromatographic separation was achieved on a C 18 column (2.1 × 30 mm, 3.5 μm) using acetonitrile-water (90:10, v/v; water included 0.1% formic acid) as the mobile phase. Mass detection was carried out using positive electrospray ionization in multiple reaction monitoring mode. The calibration curve was linear from 0.5 to 2000 ng/mL (r 2  = 0.9998). The intra- and inter-day accuracy and precision were within the acceptable limits of ±10% for all tilmicosin concentrations. The recoveries ranged from 95 to 99% for the three tested concentrations. The LC-MS/MS method described herein was simple, fast and less laborious than other methods, achieved high sensitivity using a small sample volume, and was successfully applied to pharmacokinetic studies of tilmicosin enteric granules after oral delivery to pigs. In comparison with tilmicosin premix, tilmicosin enteric granules slowed the elimination rate of tilmicosin, prolonged its period of action and significantly improved its bioavailability. Copyright © 2016 John Wiley & Sons, Ltd.

  18. Simultaneous LC-MS/MS determination of phenylbutyrate, phenylacetate benzoate and their corresponding metabolites phenylacetylglutamine and hippurate in blood and urine.

    PubMed

    Laryea, Maurice D; Herebian, Diran; Meissner, Thomas; Mayatepek, Ertan

    2010-12-01

    Inborn errors of urea metabolism result in hyperammonemia. Treatment of urea cycle disorders can effectively lower plasma ammonium levels and results in survival in the majority of patients. Available medications for treating urea cycle disorders include sodium benzoate (BA), sodium phenylacetate (PAA), and sodium phenylbutyrate (PBA) and are given to provide alternate routes for disposition of waste nitrogen excretion. In this study, we develop and validate a liquid chromatography tandem mass spectrometry (LC-MS/MS) method for simultaneous determination of benzoic acid, phenylacetic acid, phenylbutyric acid, phenylacetylglutamine, and hippuric acid in plasma and urine from children with inborn errors of urea synthesis. Plasma extracts and diluted urine samples were injected on a reverse-phase column and identified and quantified by selected reaction monitoring (SRM) in negative ion mode. Deuterated analogues served as internal standards. Analysis time was 7 min. Assay precision, accuracy, and linearity and sample stability were determined using enriched samples. Quantification limits of the method were 100 ng/ml (0.3-0.8 μmol/L) for all analytes, and recoveries were >90%. Inter- and intraday relative standard deviations were <10%. Our newly developed LC-MS/MS represents a robust, sensitive, and rapid method that allows simultaneous determination of the five compounds in plasma and urine.

  19. Ultrafast quantification of β-lactam antibiotics in human plasma using UPLC-MS/MS.

    PubMed

    Carlier, Mieke; Stove, Veronique; De Waele, Jan J; Verstraete, Alain G

    2015-01-26

    There is an increasing interest in monitoring plasma concentrations of β-lactam antibiotics. The objective of this work was to develop and validate a fast ultra-performance liquid chromatographic method with tandem mass spectrometric detection (UPLC-MS/MS) for simultaneous quantification of amoxicillin, cefuroxime, ceftazidime, meropenem and piperacillin with minimal turn around time. Sample clean-up included protein precipitation with acetonitrile containing 5 deuterated internal standards, and subsequent dilution of the supernatant with water after centrifugation. Runtime was only 2.5 min. Chromatographic separation was performed on a Waters Acquity UPLC system using a BEH C18 column (1.7 μm, 100 mm × 2.1 mm) applying a binary gradient elution of water and methanol both containing 0.1% formic acid and 2 mmol/L ammonium acetate on a Water TQD instrument in MRM mode. All compounds were detected in electrospray positive ion mode and could be quantified between 1 and 100 mg/L for amoxicillin and cefuroxime, between 0.5 and 80 mg/L for meropenem and ceftazidime, and between 1 and 150 mg/L for piperacillin. The method was validated in terms of precision, accuracy, linearity, matrix effect and recovery and has been compared to a previously published UPLC-MS/MS method. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Simultaneous determination of phosphatidylcholine-derived quaternary ammonium compounds by a LC-MS/MS method in human blood plasma, serum and urine samples.

    PubMed

    Steuer, Christian; Schütz, Philipp; Bernasconi, Luca; Huber, Andreas R

    2016-01-01

    The determination of circulating trimethylamine-N-oxide (TMAO), choline, betaine, l-carnitine and O-acetyl-l-carnitine concentration in different human matrices is of great clinical interest. Recent results highlighted the prognostic value of TMAO and quaternary ammonium containing metabolites in the field of cardiovascular and kidney diseases. Herein, we report a method for the rapid and simultaneous measurement of closely related phosphatidylcholine-derived metabolites in three different biological matrices by stable isotope dilution assay. Plasma, serum and urine samples were simply deproteinized and separated by HILIC-chromatography. Detection and quantification were performed using LC-MS/MS with electrospray ionization in positive mode. For accuracy and precision, full calibration was performed covering more than the full reference range. Assay performance metrics include intra- and interday imprecision were below 10% for all analytes. To exclude matrix effects standard addition methods were applied for all matrices. It was shown that calibration standards and quality control prepared in water can be used instead of matrix-matched calibration and controls. The LC/MS/MS-based assay described in this article may improve future clinical studies evaluating TMAO and related substances as prognostic markers for cardiovascular risk and all-cause mortality in different patient populations. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Modified HPLC-ESI-MS Method for Glycated Hemoglobin Quantification Based on the IFCC Reference Measurement Procedure and Its Application for Quantitative Analyses in Clinical Laboratories of China.

    PubMed

    Song, Zhixin; Xie, Baoyuan; Ma, Huaian; Zhang, Rui; Li, Pengfei; Liu, Lihong; Yue, Yuhong; Zhang, Jianping; Tong, Qing; Wang, Qingtao

    2016-09-01

    The level of glycated hemoglobin (HbA1c ) has been recognized as an important indicator of long-term glycemic control. However, the HbA1c measurement is not currently included as a diagnostic determinant in China. Current study aims to assess a candidate modified International Federation of Clinical Chemistry reference method for the forthcoming standardization of HbA1c measurements in China. The HbA1c concentration was measured using a modified high-performance liquid chromatography-electrospray ionization-mass spectrometry (HPLC-ESI-MS) method. The modified method replaces the propylcyanide column with a C18 reversed-phase column, which has a lower cost and is more commonly used in China, and uses 0.1% (26.5 mmol/l) formic acid instead of trifluoroacetic acid. Moreover, in order to minimize matrix interference and reduce the running time, a solid-phase extraction was employed. The discrepancies between HbA1c measurements using conventional methods and the HPLC-ESI-MS method were clarified in clinical samples from healthy people and diabetic patients. Corresponding samples were distributed to 89 hospitals in Beijing for external quality assessment. The linearity, reliability, and accuracy of the modified HPLC-ESI-MS method with a shortened running time of 6 min were successfully validated. Out of 89 hospitals evaluated, the relative biases of HbA1c concentrations were < 8% for 74 hospitals and < 5% for 60 hospitals. Compared with other conventional methods, HbA1c concentrations determined by HPLC methods were similar to the values obtained from the current HPLC-ESI-MS method. The HPLC-ESI-MS method represents an improvement over existing methods and provides a simple, stable, and rapid HbA1c measurement with strong signal intensities and reduced ion suppression. © 2015 Wiley Periodicals, Inc.

  2. High-throughput method for the determination of residues of β-lactam antibiotics in bovine milk by LC-MS/MS.

    PubMed

    Jank, Louise; Martins, Magda Targa; Arsand, Juliana Bazzan; Hoff, Rodrigo Barcellos; Barreto, Fabiano; Pizzolato, Tânia Mara

    2015-01-01

    This study describes the development and validation procedures for scope extension of a method for the determination of β-lactam antibiotic residues (ampicillin, amoxicillin, penicillin G, penicillin V, oxacillin, cloxacillin, dicloxacillin, nafcillin, ceftiofur, cefquinome, cefoperazone, cephapirine, cefalexin and cephalonium) in bovine milk. Sample preparation was performed by liquid-liquid extraction (LLE) followed by two clean-up steps, including low temperature purification (LTP) and a solid phase dispersion clean-up. Extracts were analysed using a liquid chromatography-electrospray-tandem mass spectrometry system (LC-ESI-MS/MS). Chromatographic separation was performed in a C18 column, using methanol and water (both with 0.1% of formic acid) as mobile phase. Method validation was performed according to the criteria of Commission Decision 2002/657/EC. Main validation parameters such as linearity, limit of detection, decision limit (CCα), detection capability (CCβ), accuracy, and repeatability were determined and were shown to be adequate. The method was applied to real samples (more than 250) and two milk samples had levels above maximum residues limits (MRLs) for cloxacillin - CLX and cefapirin - CFAP.

  3. Multi-mycotoxin stable isotope dilution LC-MS/MS method for Fusarium toxins in beer.

    PubMed

    Habler, Katharina; Gotthardt, Marina; Schüler, Jan; Rychlik, Michael

    2017-03-01

    A stable isotope dilution LC-MS/MS multi-mycotoxin method was developed for 12 different Fusarium toxins including modified mycotoxins in beer (deoxynivalenol-3-glucoside, deoxynivalenol, 3-acetyldeoxynivalenol, 15-acetyl-deoxynivalenol, HT2-toxin, T2-toxin, enniatin B, B1, A1, A, beauvericin and zearalenone). As sample preparation and purification of beer a combined solid phase extraction for trichothecenes, enniatins, beauvericin and zearalenone was firstly developed. The validation of the new method gave satisfying results: intra-day and inter-day precision and recoveries were 1-5%, 2-8% and 72-117%, respectively. In total, 61 different organic and conventional beer samples from Germany and all over the world were analyzed by using the newly developed multi-mycotoxin method. In summary, deoxynivalenol, deoxynivalenol-3-glucoside, 3-acetyldeoxynivaleneol and enniatin B were quantified in rather low contents in the investigated beer samples. None of the other monitored Fusarium toxins like 15-acetyldeoxynivalenol, HT2- and T2-toxin, zearalenone, enniatin B1, A1, A or beauvericin were detectable. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Validation of a mass spectrometry-based method for milk traces detection in baked food.

    PubMed

    Lamberti, Cristina; Cristina, Lamberti; Acquadro, Elena; Elena, Acquadro; Corpillo, Davide; Davide, Corpillo; Giribaldi, Marzia; Marzia, Giribaldi; Decastelli, Lucia; Lucia, Decastelli; Garino, Cristiano; Cristiano, Garino; Arlorio, Marco; Marco, Arlorio; Ricciardi, Carlo; Carlo, Ricciardi; Cavallarin, Laura; Laura, Cavallarin; Giuffrida, Maria Gabriella; Gabriella, Giuffrida Maria

    2016-05-15

    A simple validated LC-MS/MS-based method was set up to detect milk contamination in bakery products, taking the effects of food processing into account for the evaluation of allergen recovery and quantification. Incurred cookies were prepared at eight levels of milk contamination and were cooked to expose all milk components, including allergenic proteins, to food processing conditions. Remarkable results were obtained in term of sufficiently low LOD and LOQ (1.3 and 4 mg/kg cookies, respectively). Precision was calculated as intra-day repeatability (RSD in the 5-20% range) and inter-day repeatability (4 days; RSD never exceeded 12%). The extraction recovery values ranged from 20% to 26%. Method applicability was evaluated by analysing commercial cookies labelled either as "milk-free" or "may contain milk". Although the ELISA methodology is considered the gold standard for detecting allergens in foods, this robust LC-MS/MS approach should be a useful confirmatory method for assessing and certifying "milk-free" food products. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Boron Content of Some Foods Consumed in Istanbul, Turkey.

    PubMed

    Kuru, Ruya; Yilmaz, Sahin; Tasli, Pakize Neslihan; Yarat, Aysen; Sahin, Fikrettin

    2018-04-14

    The boron content was determined in 42 different foods consumed in Istanbul, Turkey. Eleven species of fruit, ten species of vegetable, eight species of food of animal origin, four species of grain, two species of nuts, two species of legume, and five other kinds of foods were included to this study. They were analyzed by two methods: Inductively coupled plasma mass spectrometry (ICP-MS) technique and carminic acid assay, and the results of two methods were also compared. Boron concentration in foods ranged between 0.06-37.2 mg/kg. Nuts had the highest boron content while foods of animal origin had the lowest. A strong correlation was found between the results of the carminic acid assay and the ICP-MS technique (p = 0.0001, Pearson correlation coefficient: r = 0.956). Bland Altman analysis also supported this correlation. ICP-MS is one of the most common, reliable, and powerful method for boron determination. The results of our study show that spectrophotometric carminic acid assay can provide similar results to ICP-MS, and the boron content in food materials can be also determined by spectrophotometric method.

  6. Recent Achievements in Characterizing the Histone Code and Approaches to Integrating Epigenomics and Systems Biology.

    PubMed

    Janssen, K A; Sidoli, S; Garcia, B A

    2017-01-01

    Functional epigenetic regulation occurs by dynamic modification of chromatin, including genetic material (i.e., DNA methylation), histone proteins, and other nuclear proteins. Due to the highly complex nature of the histone code, mass spectrometry (MS) has become the leading technique in identification of single and combinatorial histone modifications. MS has now overcome antibody-based strategies due to its automation, high resolution, and accurate quantitation. Moreover, multiple approaches to analysis have been developed for global quantitation of posttranslational modifications (PTMs), including large-scale characterization of modification coexistence (middle-down and top-down proteomics), which is not currently possible with any other biochemical strategy. Recently, our group and others have simplified and increased the effectiveness of analyzing histone PTMs by improving multiple MS methods and data analysis tools. This review provides an overview of the major achievements in the analysis of histone PTMs using MS with a focus on the most recent improvements. We speculate that the workflow for histone analysis at its state of the art is highly reliable in terms of identification and quantitation accuracy, and it has the potential to become a routine method for systems biology thanks to the possibility of integrating histone MS results with genomics and proteomics datasets. © 2017 Elsevier Inc. All rights reserved.

  7. LC-MSn Analysis of Isomeric Chondroitin Sulfate Oligosaccharides Using a Chemical Derivatization Strategy

    PubMed Central

    Huang, Rongrong; Pomin, Vitor H.; Sharp, Joshua S.

    2011-01-01

    Improved methods for structural analyses of glycosaminoglycans (GAGs) are required to understand their functional roles in various biological processes. Major challenges in structural characterization of complex GAG oligosaccharides using liquid chromatography-mass spectrometry (LC-MS) include the accurate determination of the patterns of sulfation due to gas-phase losses of the sulfate groups upon collisional activation and inefficient on-line separation of positional sulfation isomers prior to MS/MS analyses. Here, a sequential chemical derivatization procedure including permethylation, desulfation, and acetylation was demonstrated to enable both on-line LC separation of isomeric mixtures of chondroitin sulfate (CS) oligosaccharides and accurate determination of sites of sulfation by MSn. The derivatized oligosaccharides have sulfate groups replaced with acetyl groups, which are sufficiently stable to survive MSn fragmentation and reflect the original sulfation patterns. A standard reversed-phase LC-MS system with a capillary C18 column was used for separation, and MSn experiments using collision-induced dissociation (CID) were performed. Our results indicate that the combination of this derivatization strategy and MSn methodology enables accurate identification of the sulfation isomers of CS hexasaccharides with either saturated or unsaturated nonreducing ends. Moreover, derivatized CS hexasaccharide isomer mixtures become separable by LC-MS method due to different positions of acetyl modifications. PMID:21953261

  8. A UHPLC-MS/MS method for profiling multifunctional steroids in human hair.

    PubMed

    Dong, Zhen; Wang, Caihong; Zhang, Jinlan; Wang, Zhe

    2017-08-01

    It is important to profile steroids in many physiological and pathological processes. Recently, hair has been used for the long-term measurement of endogenous steroid hormones. Analyzing hair has advantages of being noninvasive and time sequential compared with other bio-specimens. Liquid chromatography-mass spectrometry (LC-MS) techniques have been widely used over the past decades; however, it is challenging to profile estrogens in hair by LC-MS, and more comprehensive steroid profiling is required. In this paper, an ultra high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method was developed to simultaneously profile 28 multifunctional steroids, including corticosteroids (n = 6), estrogens (n = 13), androgens (n = 5) and progestogens (n = 4), in human scalp hair in a single run. To optimize the sample preparation procedure, we evaluated extraction time, post-incubation purification and hair fragment length; 30 mg hair samples were washed with hexane, cut into 5 mm pieces and incubated in methanol for 18 h at 25 °C. Methanol extraction derivatized using Girard P and dansyl chloride reagent was analyzed within 25 min using an automated injection program combined with a diverter valve switch and step analysis (AIDSA). The method was well validated in terms of linearity, limit of detection (LOD), limit of quantification (LOQ), precision, accuracy, matrix effect and recovery, and was successfully applied to a steroid profile from male and female hairs. Significant differences were observed between genders. In addition, steroids showed a declining trend from the proximal to more distal hair segments; thus, care should be taken when obtaining hair samples for analysis to account for this difference in steroid levels along the length of hair. Graphical Abstract The workflow of the estabished UHPLC-MS/MS method.

  9. Simultaneous determination of five plant growth regulators in fruits by modified quick, easy, cheap, effective, rugged, and safe (QuEChERS) extraction and liquid chromatography-tandem mass spectrometry.

    PubMed

    Shi, Xiaomei; Jin, Fen; Huang, Yuting; Du, Xinwei; Li, Chunmei; Wang, Miao; Shao, Hua; Jin, Maojun; Wang, Jing

    2012-01-11

    An effective method using liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed and optimized to obtain a complete separation of five representative plant growth regulators (PGRs) [gibberellic acid, 2,4-dichlorophenoxyacetic acid (2,4-D), thidiazuron, forchlorfenuron, and paclobutrazol] in fruits. Extraction was performed with acetonitrile containing 0.1% (v/v) acetic acid, applying modified quick, easy, cheap, effective, rugged, and safe (QuEChERS) methodology. LC-MS/MS conditions including composition of mobile phases and mass spectrometry (MS) conditions were evaluated to achieve the highest sensitivity in MS detection. All of the data acquisition was employed in the segmented multiple-reaction monitoring mode for the selected negative and positive transition ions. The octadecylsilyl (C18) dispersive solid-phase extraction (SPE) sorbent was found to provide the more satisfied recoveries than primary secondary amine (PSA) and graphitized carbon black (GCB) for five target PGRs. The optimized method allowed for recoveries of 76-112% for the five PGRs from fruit samples with relative standard deviation (RSD) values less than 10%. Limits of quantification (0.5-16.5 μg/kg) were lower than the maximum limit of residues established for PGRs. The results demonstrated that the developed LC-MS/MS and QuEChERS extraction method is highly effective for analyzing trace amounts of target PGRs in fruit samples. Finally, the method was successfully used to detect residual PGRs in Beijing, China, in 2010. The concentrations of 2,4-D (5.1-1503 μg/kg) and paclobutrazol (1-1381 μg/kg) found in orange and peach, respectively, suggesting that the use of these PGRs in these fruits should be regulated in China in the future.

  10. A survey of computational methods and error rate estimation procedures for peptide and protein identification in shotgun proteomics

    PubMed Central

    Nesvizhskii, Alexey I.

    2010-01-01

    This manuscript provides a comprehensive review of the peptide and protein identification process using tandem mass spectrometry (MS/MS) data generated in shotgun proteomic experiments. The commonly used methods for assigning peptide sequences to MS/MS spectra are critically discussed and compared, from basic strategies to advanced multi-stage approaches. A particular attention is paid to the problem of false-positive identifications. Existing statistical approaches for assessing the significance of peptide to spectrum matches are surveyed, ranging from single-spectrum approaches such as expectation values to global error rate estimation procedures such as false discovery rates and posterior probabilities. The importance of using auxiliary discriminant information (mass accuracy, peptide separation coordinates, digestion properties, and etc.) is discussed, and advanced computational approaches for joint modeling of multiple sources of information are presented. This review also includes a detailed analysis of the issues affecting the interpretation of data at the protein level, including the amplification of error rates when going from peptide to protein level, and the ambiguities in inferring the identifies of sample proteins in the presence of shared peptides. Commonly used methods for computing protein-level confidence scores are discussed in detail. The review concludes with a discussion of several outstanding computational issues. PMID:20816881

  11. Pulsed Direct Current Electrospray: Enabling Systematic Analysis of Small Volume Sample by Boosting Sample Economy.

    PubMed

    Wei, Zhenwei; Xiong, Xingchuang; Guo, Chengan; Si, Xingyu; Zhao, Yaoyao; He, Muyi; Yang, Chengdui; Xu, Wei; Tang, Fei; Fang, Xiang; Zhang, Sichun; Zhang, Xinrong

    2015-11-17

    We had developed pulsed direct current electrospray ionization mass spectrometry (pulsed-dc-ESI-MS) for systematically profiling and determining components in small volume sample. Pulsed-dc-ESI utilized constant high voltage to induce the generation of single polarity pulsed electrospray remotely. This method had significantly boosted the sample economy, so as to obtain several minutes MS signal duration from merely picoliter volume sample. The elongated MS signal duration enable us to collect abundant MS(2) information on interested components in a small volume sample for systematical analysis. This method had been successfully applied for single cell metabolomics analysis. We had obtained 2-D profile of metabolites (including exact mass and MS(2) data) from single plant and mammalian cell, concerning 1034 components and 656 components for Allium cepa and HeLa cells, respectively. Further identification had found 162 compounds and 28 different modification groups of 141 saccharides in a single Allium cepa cell, indicating pulsed-dc-ESI a powerful tool for small volume sample systematical analysis.

  12. Rapid quantification of underivatized amino acids in plasma by hydrophilic interaction liquid chromatography (HILIC) coupled with tandem mass-spectrometry.

    PubMed

    Prinsen, Hubertus C M T; Schiebergen-Bronkhorst, B G M; Roeleveld, M W; Jans, J J M; de Sain-van der Velden, M G M; Visser, G; van Hasselt, P M; Verhoeven-Duif, N M

    2016-09-01

    Amino acidopathies are a class of inborn errors of metabolism (IEM) that can be diagnosed by analysis of amino acids (AA) in plasma. Current strategies for AA analysis include cation exchange HPLC with post-column ninhydrin derivatization, GC-MS, and LC-MS/MS-related methods. Major drawbacks of the current methods are time-consuming procedures, derivative problems, problems with retention, and MS-sensitivity. The use of hydrophilic interaction liquid chromatography (HILIC) columns is an ideal separation mode for hydrophilic compounds like AA. Here we report a HILIC-method for analysis of 36 underivatized AA in plasma to detect defects in AA metabolism that overcomes the major drawbacks of other methods. A rapid, sensitive, and specific method was developed for the analysis of AA in plasma without derivatization using HILIC coupled with tandem mass-spectrometry (Xevo TQ, Waters). Excellent separation of 36 AA (24 quantitative/12 qualitative) in plasma was achieved on an Acquity BEH Amide column (2.1×100 mm, 1.7 μm) in a single MS run of 18 min. Plasma of patients with a known IEM in AA metabolism was analyzed and all patients were correctly identified. The reported method analyzes 36 AA in plasma within 18 min and provides baseline separation of isomeric AA such as leucine and isoleucine. No separation was obtained for isoleucine and allo-isoleucine. The method is applicable to study defects in AA metabolism in plasma.

  13. Application of LC/MS/MS Techniques to Development of US ...

    EPA Pesticide Factsheets

    This presentation will describe the U.S. EPA’s drinking water and ambient water method development program in relation to the process employed and the typical challenges encountered in developing standardized LC/MS/MS methods for chemicals of emerging concern. The EPA’s Drinking Water Contaminant Candidate List and Unregulated Contaminant Monitoring Regulations, which are the driving forces behind drinking water method development, will be introduced. Three drinking water LC/MS/MS methods (Methods 537, 544 and a new method for nonylphenol) and two ambient water LC/MS/MS methods for cyanotoxins will be described that highlight some of the challenges encountered during development of these methods. This presentation will provide the audience with basic understanding of EPA's drinking water method development program and an introduction to two new ambient water EPA methods.

  14. Detection, characterization and identification of phenolic acids in Danshen using high-performance liquid chromatography with diode array detection and electrospray ionization mass spectrometry.

    PubMed

    Liu, Ai-Hua; Guo, Hui; Ye, Min; Lin, Yan-Hua; Sun, Jiang-Hao; Xu, Man; Guo, De-An

    2007-08-17

    By using HPLC-diode array detection-electrospray ion trap tandem mass spectrometry (HPLC-DAD-ESI-MS(n)) in negative ion mode, we have analyzed the fragmentation pathways of 11 phenolic acids which were isolated from Danshen. Then the extract of Danshen was analyzed, and a total of 42 phenolic acids, including sixteen new minor constituents, were identified or tentatively identified for the first time. A new solid-phase extraction (SPE) method, new HPLC separation method, new liquid chromatography (LC)-MS and LC-MS(n) (n=3-5) data and proposed fragmentation pathways, LC retention time for phenolic acids are reported.

  15. An Updated Meta-Analysis of Risk of Multiple Sclerosis following Infectious Mononucleosis

    PubMed Central

    Handel, Adam E.; Williamson, Alexander J.; Disanto, Giulio; Handunnetthi, Lahiru; Giovannoni, Gavin; Ramagopalan, Sreeram V.

    2010-01-01

    Background Multiple sclerosis (MS) appears to develop in genetically susceptible individuals as a result of environmental exposures. Epstein-Barr virus (EBV) infection is an almost universal finding among individuals with MS. Symptomatic EBV infection as manifested by infectious mononucleosis (IM) has been shown in a previous meta-analysis to be associated with the risk of MS, however a number of much larger studies have since been published. Methods/Principal Findings We performed a Medline search to identify articles published since the original meta-analysis investigating MS risk following IM. A total of 18 articles were included in this study, including 19390 MS patients and 16007 controls. We calculated the relative risk of MS following IM using a generic inverse variance with random effects model. This showed that the risk of MS was strongly associated with IM (relative risk (RR) 2.17; 95% confidence interval 1.97–2.39; p<10−54). Discussion Our results establish firmly that a history of infectious mononucleosis significantly increases the risk of multiple sclerosis. Future work should focus on the mechanism of this association and interaction with other risk factors. PMID:20824132

  16. The challenges of healthcare delivery to people with multiple sclerosis in Iran

    PubMed Central

    Yazdannik, Ahmadreza; Abolhassani, Shahla; Taleghani, Fariba; Zamani, Ahmadreza

    2015-01-01

    Background: Multiple sclerosis (MS) is a chronic disease prevalent in young and middle-aged people. Patients with MS often have numerous complicated needs and, consequently, require a broad range of health services. Results of a number of studies indicate that patients’ needs are only partially met. Aims: This study was conducted to explore the challenges of healthcare delivery to patients with MS in Iran. Materials and Methods: In this qualitative case study, 43 participants selected through purposeful sampling were interviewed using semi-structured method in the cities of Isfahan and Tehran in 2012–2013. Besides the interview, documentations relevant to healthcare delivery were collected from different sources, including websites of all Iranian universities of medical sciences, insurance organizations, patients’ weblogs, news agencies, the MS Center forum for MS patients, and MS Payam bimonthly. The data were analyzed through the constant comparative analysis. Results: The data were categorized into four main categories, including functional challenges (diagnosis problems, failure to pay attention to patient needs, failure to follow-up, and miscommunication), administrative challenges (resource allocation and supervision), policy-making challenges (lack of comprehensive services, bureaucracy, and problems in provision of medications), and structural challenges (difficult access to services, lack of comprehensive centers, space limit, and long wait). Conclusion: Despite all attempts of governmental and nongovernmental organizations for healthcare delivery to MS patients, these services cannot satisfy all needs of the patients. In this regard, service providers and administrators should pay more attention to the needs and expectations of patients and their families. PMID:27462625

  17. Dimensions of Credibility in Models and Simulations

    NASA Technical Reports Server (NTRS)

    Steele, Martin J.

    2008-01-01

    Based on the National Aeronautics and Space Administration's (NASA's) work in developing a standard for models and simulations (M&S), the subject of credibility in M&S became a distinct focus. This is an indirect result from the Space Shuttle Columbia Accident Investigation Board (CAIB), which eventually resulted in an action, among others, to improve the rigor in NASA's M&S practices. The focus of this action came to mean a standardized method for assessing and reporting results from any type of M&S. As is typical in the standards development process, this necessarily developed into defming a common terminology base, common documentation requirements (especially for M&S used in critical decision making), and a method for assessing the credibility of M&S results. What surfaced in the development of the NASA Standard was the various dimensions credibility to consider when accepting the results from any model or simulation analysis. The eight generally relevant factors of credibility chosen in the NASA Standard proved only one aspect in the dimensionality of M&S credibility. At the next level of detail, the full comprehension of some of the factors requires an understanding along a couple of dimensions as well. Included in this discussion are the prerequisites for the appropriate use of a given M&S, the choice of factors in credibility assessment with their inherent dimensionality, and minimum requirements for fully reporting M&S results.

  18. [Determination of heavy metals in four traditional Chinese medicines by ICP-MS].

    PubMed

    Wen, Hui-Min; Chen, Xiao-Hui; Dong, Ting-Xia; Zhan, Hua-Qiang; Bi, Kai-Shun

    2006-08-01

    To establish a ICP-MS method for the determination of heavy metals, including As, Hg, Pb, Cd, in four traditional Chinese medicines. The samples were digested by closed-versel microwave. The four heavy metals were directly analyzed by ICP-MS. Select internal standard element in for the method by which the analyse signal drife is corrected by the signal of another element (internal standard elements) added to both the standard solution and sample. For all of the analyzed heary methals, the correlative coefficient of the calibration curves was over 0.999 2. The recovery rates of the procedure were 97.5%-108.0%, and its RSD was lower than 11.6%. This method was convenient, quick-acquired, accurate and highly sensitive. The method can be used for the quality control of trace elements in traditional Chinese medicines and for the contents determination of traditional Chinese medicines from different habitats and species.

  19. Mass spectrometric-based stable isotopic 2-aminobenzoic acid glycan mapping for rapid glycan screening of biotherapeutics.

    PubMed

    Prien, Justin M; Prater, Bradley D; Qin, Qiang; Cockrill, Steven L

    2010-02-15

    Fast, sensitive, robust methods for "high-level" glycan screening are necessary during various stages of a biotherapeutic product's lifecycle, including clone selection, process changes, and quality control for lot release testing. Traditional glycan screening involves chromatographic or electrophoretic separation-based methods, and, although reproducible, these methods can be time-consuming. Even ultrahigh-performance chromatographic and microfluidic integrated LC/MS systems, which work on the tens of minute time scale, become lengthy when hundreds of samples are to be analyzed. Comparatively, a direct infusion mass spectrometry (MS)-based glycan screening method acquires data on a millisecond time scale, exhibits exquisite sensitivity and reproducibility, and is amenable to automated peak annotation. In addition, characterization of glycan species via sequential mass spectrometry can be performed simultaneously. Here, we demonstrate a quantitative high-throughput MS-based mapping approach using stable isotope 2-aminobenzoic acid (2-AA) for rapid "high-level" glycan screening.

  20. Comparative evaluation of the identification of rapidly growing non-tuberculous mycobacteria by mass spectrometry (MALDI-TOF MS), GenoType Mycobacterium CM/AS assay and partial sequencing of the rpoβ gene with phylogenetic analysis as a reference method.

    PubMed

    Costa-Alcalde, José Javier; Barbeito-Castiñeiras, Gema; González-Alba, José María; Aguilera, Antonio; Galán, Juan Carlos; Pérez-Del-Molino, María Luisa

    2018-06-02

    The American Thoracic Society and the Infectious Diseases Society of America recommend that clinically significant non-tuberculous mycobacteria (NTM) should be identified to the species level in order to determine their clinical significance. The aim of this study was to evaluate identification of rapidly growing NTM (RGM) isolated from clinical samples by using MALDI-TOF MS and a commercial molecular system. The results were compared with identification using a reference method. We included 46 clinical isolates of RGM and identified them using the commercial molecular system GenoType ® CM/AS (Hain, Lifescience, Germany), MALDI-TOF MS (Bruker) and, as reference method, partial rpoβ gene sequencing followed by BLAST and phylogenetic analysis with the 1093 sequences available in the GeneBank. The degree of agreement between GenoType ® and MALDI-TOF MS and the reference method, partial rpoβ sequencing, was 27/43 (62.8%) and 38/43 cases (88.3%) respectively. For all the samples correctly classified by GenoType ® , we obtained the same result with MALDI-TOF MS (27/27). However, MALDI-TOF MS also correctly identified 68.75% (11/16) of the samples that GenoType ® had misclassified (p=0.005). MALDI-TOF MS classified significantly better than GenoType ® . When a MALDI-TOF MS score >1.85 was achieved, MALDI-TOF MS and partial rpoβ gene sequencing were equivalent. GenoType ® was not able to distinguish between species belonging to the M. fortuitum complex. MALDI-TOF MS methodology is simple, rapid and associated with lower consumable costs than GenoType ® . The partial rpoβ sequencing methods with BLAST and phylogenetic analysis were not able to identify some RGM unequivocally. Therefore, sequencing of additional regions would be indicated in these cases. Copyright © 2018 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  1. Prospective Evaluation of a Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry System in a Hospital Clinical Microbiology Laboratory for Identification of Bacteria and Yeasts: a Bench-by-Bench Study for Assessing the Impact on Time to Identification and Cost-Effectiveness

    PubMed Central

    Tan, K. E.; Ellis, B. C.; Lee, R.; Stamper, P. D.; Zhang, S. X.

    2012-01-01

    Matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS) has been found to be an accurate, rapid, and inexpensive method for the identification of bacteria and yeasts. Previous evaluations have compared the accuracy, time to identification, and costs of the MALDI-TOF MS method against standard identification systems or commercial panels. In this prospective study, we compared a protocol incorporating MALDI-TOF MS (MALDI protocol) with the current standard identification protocols (standard protocol) to determine the performance in actual practice using a specimen-based, bench-by-bench approach. The potential impact on time to identification (TTI) and costs had MALDI-TOF MS been the first-line identification method was quantitated. The MALDI protocol includes supplementary tests, notably for Streptococcus pneumoniae and Shigella, and indications for repeat MALDI-TOF MS attempts, often not measured in previous studies. A total of 952 isolates (824 bacterial isolates and 128 yeast isolates) recovered from 2,214 specimens were assessed using the MALDI protocol. Compared with standard protocols, the MALDI protocol provided identifications 1.45 days earlier on average (P < 0.001). In our laboratory, we anticipate that the incorporation of the MALDI protocol can reduce reagent and labor costs of identification by $102,424 or 56.9% within 12 months. The model included the fixed annual costs of the MALDI-TOF MS, such as the cost of protein standards and instrument maintenance, and the annual prevalence of organisms encountered in our laboratory. This comprehensive cost analysis model can be generalized to other moderate- to high-volume laboratories. PMID:22855510

  2. Pharmacological and Non-pharmacological Therapies of Cognitive Impairment in Multiple Sclerosis.

    PubMed

    Miller, Elzbieta; Morel, Agnieszka; Redlicka, Justyna; Miller, Igor; Saluk, Joanna

    2018-01-01

    Cognitive impairment is one of the most important clinical features of neurodegenerative disorders including multiple sclerosis (MS). Conducted research shows that up to 65 percent of MS patients have cognitive deficits such as episodic memory, sustained attention, reduced verbal fluency; however, the cognitive MS domain is information processing speed. It is the first syndrome of cognitive dysfunction and the most widely affected in MS. Occasionally these impairments occur even before the appearance of physical symptoms. Therefore, this review focused on the current status of our knowledge about possible methods of treatment cognitive impairment in MS patients including novel strategies. Research and online content was performed using Medline and EMBASE databases. The most recent research suggests that cognitive impairment is correlated with brain lesion volume and brain atrophy. The examination of the cognitive impairment is usually based on particular neuropsychological batteries. However, it can be not enough to make a precise diagnosis. This creates a demand to find markers that might be useful for identifying patients with risk of cognitive impairment at an early stage of the disease. Currently the most promising methods consist of neuroimaging indicators, such as diffusion tensor imaging, the magnetization transfer ratio, and N-acetyl aspartate levels. Diagnosis problems are strictly connected with treatment procedures. There are two main cognitive therapies: pharmacological (disease modifying drugs (DMD), symptomatic treatments) and non-pharmacological interventions that are focused on psychological and physical rehabilitation. Some trials have shown a positive association between physical activity and the cognitive function. This article is an overview of the current state of knowledge related to cognition impairment treatment in MS. Additionally, novel strategies for cognitive impairments such as cryostimulation and other complementary methods are presented. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  3. Prospective evaluation of a matrix-assisted laser desorption ionization-time of flight mass spectrometry system in a hospital clinical microbiology laboratory for identification of bacteria and yeasts: a bench-by-bench study for assessing the impact on time to identification and cost-effectiveness.

    PubMed

    Tan, K E; Ellis, B C; Lee, R; Stamper, P D; Zhang, S X; Carroll, K C

    2012-10-01

    Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has been found to be an accurate, rapid, and inexpensive method for the identification of bacteria and yeasts. Previous evaluations have compared the accuracy, time to identification, and costs of the MALDI-TOF MS method against standard identification systems or commercial panels. In this prospective study, we compared a protocol incorporating MALDI-TOF MS (MALDI protocol) with the current standard identification protocols (standard protocol) to determine the performance in actual practice using a specimen-based, bench-by-bench approach. The potential impact on time to identification (TTI) and costs had MALDI-TOF MS been the first-line identification method was quantitated. The MALDI protocol includes supplementary tests, notably for Streptococcus pneumoniae and Shigella, and indications for repeat MALDI-TOF MS attempts, often not measured in previous studies. A total of 952 isolates (824 bacterial isolates and 128 yeast isolates) recovered from 2,214 specimens were assessed using the MALDI protocol. Compared with standard protocols, the MALDI protocol provided identifications 1.45 days earlier on average (P < 0.001). In our laboratory, we anticipate that the incorporation of the MALDI protocol can reduce reagent and labor costs of identification by $102,424 or 56.9% within 12 months. The model included the fixed annual costs of the MALDI-TOF MS, such as the cost of protein standards and instrument maintenance, and the annual prevalence of organisms encountered in our laboratory. This comprehensive cost analysis model can be generalized to other moderate- to high-volume laboratories.

  4. Hybrid Imaging Labels: Providing the Link Between Mass Spectrometry-Based Molecular Pathology and Theranostics

    PubMed Central

    Buckle, Tessa; van der Wal, Steffen; van Malderen, Stijn J.M.; Müller, Larissa; Kuil, Joeri; van Unen, Vincent; Peters, Ruud J.B.; van Bemmel, Margaretha E.M.; McDonnell, Liam A.; Velders, Aldrik H.; Koning, Frits; Vanhaeke, Frank; van Leeuwen, Fijs W. B.

    2017-01-01

    Background: Development of theranostic concepts that include inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS (LA-ICP-MS) imaging can be hindered by the lack of a direct comparison to more standardly used methods for in vitro and in vivo evaluation; e.g. fluorescence or nuclear medicine. In this study a bimodal (or rather, hybrid) tracer that contains both a fluorescent dye and a chelate was used to evaluate the existence of a direct link between mass spectrometry (MS) and in vitro and in vivo molecular imaging findings using fluorescence and radioisotopes. At the same time, the hybrid label was used to determine whether the use of a single isotope label would allow for MS-based diagnostics. Methods: A hybrid label that contained both a DTPA chelate (that was coordinated with either 165Ho or 111In) and a Cy5 fluorescent dye was coupled to the chemokine receptor 4 (CXCR4) targeting peptide Ac-TZ14011 (hybrid-Cy5-Ac-TZ4011). This receptor targeting tracer was used to 1) validate the efficacy of (165Ho-based) mass-cytometry in determining the receptor affinity via comparison with fluorescence-based flow cytometry (Cy5), 2) evaluate the microscopic binding pattern of the tracer in tumor cells using both fluorescence confocal imaging (Cy5) and LA-ICP-MS-imaging (165Ho), 3) compare in vivo biodistribution patterns obtained with ICP-MS (165Ho) and radiodetection (111In) after intravenous administration of hybrid-Cy5-Ac-TZ4011 in tumor-bearing mice. Finally, LA-ICP-MS-imaging (165Ho) was linked to fluorescence-based analysis of excised tissue samples (Cy5). Results: Analysis with both mass-cytometry and flow cytometry revealed a similar receptor affinity, respectively 352 ± 141 nM and 245 ± 65 nM (p = 0.08), but with a much lower detection sensitivity for the first modality. In vitro LA-ICP-MS imaging (165Ho) enabled clear discrimination between CXCR4 positive and negative cells, but fluorescence microscopy was required to determine the intracellular distribution. In vivo biodistribution patterns obtained with ICP-MS (165Ho) and radiodetection (111In) of the hybrid peptide were shown to be similar. Assessment of tracer distribution in excised tissues revealed the location of tracer uptake with both LA-ICP-MS-imaging and fluorescence imaging. Conclusion: Lanthanide-isotope chelation expands the scope of fluorescent/radioactive hybrid tracers to include MS-based analytical tools such as mass-cytometry, ICP-MS and LA-ICP-MS imaging in molecular pathology. In contradiction to common expectations, MS detection using a single chelate imaging agent was shown to be feasible, enabling a direct link between nuclear medicine-based imaging and theranostic methods. PMID:28255355

  5. Application of a new vitamin D blood test on the Emirati population.

    PubMed

    Shah, Iltaf; Al-Dabbagh, Bayan; Gariballa, Salah; Al-Menhali, Asma; Muhammad, Neak; Yasin, Javed; Ashraf, S Salman

    2018-06-01

    Research shows that immunoassay techniques are not the best choice for the estimation of vitamin D in human blood samples. The main reasons are that some immunoassays are not able to distinguish between 25-OHD3 and 25-OHD2 vitamin D metabolites. Furthermore, immunoassays cannot differentiate between 25OHD and inactive epimers of vitamin D. Vitamin D epimers and isobars have been known to overlap with the 25OHD signals and give false positives when tested. Liquid chromatography tandem-mass spectrometry (LC-MS/MS) can differentiate between 25OHD3 and 25OHD2. Separating epimers and isobars (which have the same molecular weight) from vitamin D is achieved through chromatographic separation from actual 25OHD peaks, although this could also cause inaccuracies in vitamin D measurements. The main aim of this study was to develop and validate an improved LC-MS/MS method (using a Shimadzu 8060 system) that could accurately detect and quantitate up to 10 different metabolites of vitamin D, as well as differentiate the epimers and isobars. The secondary aim was to apply the developed LC-MS/MS method for the accurate measurement of blood vitamin D levels in the Emirati population. The Shimadzu 8060 system was run using positive ion electrospray ionization (ESI) in Dynamic Multiple Reaction Monitoring (DMRM) mode for quantification. The method involved blood sample collection from 80 Emirati volunteers, followed by serum extraction and liquid-liquid extraction. The chromatography column used for the analysis was an Ascentis Express F5. Precursor and product ions were detected using a Shimadzu 8060 LC-MS/MS system, and 10 metabolites of vitamin D were detected and quantified, including epimers and isobars. The method validation showed good sensitivity, recovery, linearity, precision, specificity, and accuracy. Furthermore, the data showed that vitamin D epimer 3-epi-25OHD and isobar 7-α-hydroxy-4-cholesten-3-one (7αC4) accounted for a significant portion of vitamin D results in the Emirati population. We report a more reliable, reproducible, and robust LC-MS/MS method for the accurate detection of 25OHD (vitamin D) in the Emirati population. The method has the capacity to detect and separate 10 metabolites of vitamin D as well as separate 25OHD from co-eluting epimers and isobars. The method has also been successfully implemented in gauging vitamin D deficiency in the Emirati population. Thus, this improved LC-MS/MS method could prove very useful in accurately estimating the levels of vitamin D in the Emirati population and in further clinical studies. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Mutans streptococci--in families and on tooth sites. Studies on the distribution, acquisition and persistence using DNA fingerprinting.

    PubMed

    Emanuelsson, I M

    2001-01-01

    Mutans streptococci (MS) are bacteria showing several cariogenic traits. This thesis is based on the concept that humans acquire MS directly or indirectly from each other. Previous research on the transmission of the bacteria in families has indicated that children acquire MS from their mothers. Just a few studies have included fathers. Diverging results have been presented about spouses acquiring MS from each other. The information on the distribution of MS types at a tooth surface level has been limited. The methods used for identification of MS types have been refined during the years making further studies in the field interesting. The present thesis deals primarily with the distribution of MS in families. Twenty-five Swedish families including a 3-year-old first-born child (I) and 11 corresponding Chinese families (II) were studied. The Swedish families were followed up 2-5 years later (III and IV). Study V deals with the colonization of MS on tooth sites in 13 young adults. MS were isolated from bacterial plaque samples obtained from the teeth of the subjects. Identification of MS types was carried out through DNA analysis methods, REA and RAPD respectively. MS were detected in 11 of the 25 Swedish children. The distribution of MS genotypes in these families indicated that the mothers and individuals outside the family were the sources of MS to the children (I). The distribution of MS genotypes in the Chinese families (II) pointed to the fact that the father played a more pronounced role as MS source compared to in the Swedish families. The intra-familial distribution of MS seemed to be different in the two groups of families with different cultural backgrounds. At the follow-up, genotypes of MS were found again among the MS positive children and their parents. This indicated that genotypes of MS persisted. Even though some alterations in the prevalence of MS genotypes were shown (III). Among the MS negative children some had acquired the bacteria, but most of them remained MS negative by the age of 5-8 years (IV). The father was in some few cases the MS source to the child in the Swedish families (III, IV). Few spouses acquired MS from each other. It is not clear to which extent the parents' salivary levels of MS, caregiver of the child, breast-feeding or antibiotic treatment influenced the acquisition of MS in the groups studied (I-IV). Finally it was shown that several different genotypes of MS colonized a particular tooth site simultaneously. Within each individual the same genotype occurred on two or more tooth sites. Genotypes persisted 4-7 months on their site. The colonization diverged inter-individually in terms of the number and the distribution of MS genotypes on the tooth sites (V).

  7. Demonstration of Regenerable, Large-scale Ion Exchange System Using WBA Resin in Rialto, CA

    DTIC Science & Technology

    2008-03-01

    Saturation Index MCL – Maximum Contaminant Level NaOH – Sodium hydroxide NDBA – N-nitrosodi-n-butylamine NDEA – N-nitrosodiethylamine NDMA ...analyzed using EPA Method 521. NDMA was 2.6 ppt with a detection limit of 2 ppt. All other nitrosamines analyzed (including NDEA, NDBA, NDPA, NMEA...using IC/MS/MS. Nitrosamines were analyzed using EPA Method 521. NDMA was 2.6 ppt with a detection limit of 2 ppt. All other nitrosamines

  8. Demonstration of Regenerable, Large-Scale Ion Exchange System Using WBA Resin in Rialto, CA

    DTIC Science & Technology

    2008-03-05

    NDMA – N-nitrosodimethylamine NDPA – N-nitrosodi-n-propylamine NMEA – N-nitrosomethylethylamine NMOR – N-nitrosomorpholine NPDES – National Pollutant...were analyzed using EPA Method 521. NDMA was 2.6 ppt with a detection limit of 2 ppt. All other nitrosamines analyzed (including NDEA, NDBA, NDPA...ppb) using IC/MS/MS. Nitrosamines were analyzed using EPA Method 521. NDMA was 2.6 ppt with a detection limit of 2 ppt. All other nitrosamines

  9. Multiresidue analysis of 24 Water Framework Directive priority substances by on-line solid phase extraction-liquid chromatography tandem mass spectrometry in environmental waters.

    PubMed

    Rubirola, Adrià; Boleda, Mª Rosa; Galceran, Mª Teresa

    2017-04-14

    This paper reports the development of a fully multiresidue and automated on-line solid phase extraction (SPE) - liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the determination of 24 priority substances (PS) belonging to different classes (pesticides, hormones or pharmaceuticals) included in the Directive 2013/39/UE and the recent Watch List (Decision 2015/495) in water samples (drinking water, surface water, and effluent wastewaters). LC-MS/MS conditions and on-line SPE parameters such as sorbent type, sample and wash volumes were optimized. The developed method is highly sensitive (limits of detection between 0.1 and 1.4ngL -1 ) and precise (relative standard deviations lower than 8%). As part of the method validation studies, linearity, accuracy and matrix effects were assessed. The main advantage of this method over traditional off-line procedures is the minimization of tedious sample preparation increasing productivity and sample throughput. The optimized method was applied to the analysis of water samples and the results revealed the presence of 16 PS in river water and effluent water of wastewater treatment plants. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. DIGE Analysis Software and Protein Identification Approaches.

    PubMed

    Hmmier, Abduladim; Dowling, Paul

    2018-01-01

    DIGE is a high-resolution two-dimensional gel electrophoresis method, with excellent dynamic range obtained by fluorescent tag labeling of protein samples. Scanned images of DIGE gels show thousands of protein spots, each spot representing a single or a group of protein isoforms. By using commercially available software, each protein spot is defined by an outline, which is digitized and correlated with the quantity of proteins present in each spot. Software packages include DeCyder, SameSpots, and Dymension 3. In addition, proteins of interest can be excised from post-stained gels and identified with conventional mass spectrometry techniques. High-throughput mass spectrometry is performed using sophisticated instrumentation including matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF), MALDI-TOF/TOF, and liquid chromatography tandem mass spectrometry (LC-MS/MS). Tandem MS (MALDI-TOF/TOF or LC-MS/MS), analyzes fragmented peptides, resulting in amino acid sequence information, especially useful when protein spots are low abundant or where a mixture of proteins is present.

  11. An UPLC-ESI-MS/MS Assay Using 6-Aminoquinolyl-N-Hydroxysuccinimidyl Carbamate Derivatization for Targeted Amino Acid Analysis: Application to Screening of Arabidopsis thaliana Mutants.

    PubMed

    Salazar, Carolina; Armenta, Jenny M; Shulaev, Vladimir

    2012-07-06

    In spite of the large arsenal of methodologies developed for amino acid assessment in complex matrices, their implementation in metabolomics studies involving wide-ranging mutant screening is hampered by their lack of high-throughput, sensitivity, reproducibility, and/or wide dynamic range. In response to the challenge of developing amino acid analysis methods that satisfy the criteria required for metabolomic studies, improved reverse-phase high-performance liquid chromatography-mass spectrometry (RPHPLC-MS) methods have been recently reported for large-scale screening of metabolic phenotypes. However, these methods focus on the direct analysis of underivatized amino acids and, therefore, problems associated with insufficient retention and resolution are observed due to the hydrophilic nature of amino acids. It is well known that derivatization methods render amino acids more amenable for reverse phase chromatographic analysis by introducing highly-hydrophobic tags in their carboxylic acid or amino functional group. Therefore, an analytical platform that combines the 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC) pre-column derivatization method with ultra performance liquid chromatography-electrospray ionization-tandem mass spectrometry (UPLC-ESI-MS/MS) is presented in this article. For numerous reasons typical amino acid derivatization methods would be inadequate for large scale metabolic projects. However, AQC derivatization is a simple, rapid and reproducible way of obtaining stable amino acid adducts amenable for UPLC-ESI-MS/MS and the applicability of the method for high-throughput metabolomic analysis in Arabidopsis thaliana is demonstrated in this study. Overall, the major advantages offered by this amino acid analysis method include high-throughput, enhanced sensitivity and selectivity; characteristics that showcase its utility for the rapid screening of the preselected plant metabolites without compromising the quality of the metabolic data. The presented method enabled thirty-eight metabolites (proteinogenic amino acids and related compounds) to be analyzed within 10 min with detection limits down to 1.02 × 10-11 M (i.e., atomole level on column), which represents an improved sensitivity of 1 to 5 orders of magnitude compared to existing methods. Our UPLC-ESI-MS/MS method is one of the seven analytical platforms used by the Arabidopsis Metabolomics Consortium. The amino acid dataset obtained by analysis of Arabidopsis T-DNA mutant stocks with our platform is captured and open to the public in the web portal PlantMetabolomics.org. The analytical platform herein described could find important applications in other studies where the rapid, high-throughput and sensitive assessment of low abundance amino acids in complex biosamples is necessary.

  12. An UPLC-ESI-MS/MS Assay Using 6-Aminoquinolyl-N-Hydroxysuccinimidyl Carbamate Derivatization for Targeted Amino Acid Analysis: Application to Screening of Arabidopsis thaliana Mutants

    PubMed Central

    Salazar, Carolina; Armenta, Jenny M.; Shulaev, Vladimir

    2012-01-01

    In spite of the large arsenal of methodologies developed for amino acid assessment in complex matrices, their implementation in metabolomics studies involving wide-ranging mutant screening is hampered by their lack of high-throughput, sensitivity, reproducibility, and/or wide dynamic range. In response to the challenge of developing amino acid analysis methods that satisfy the criteria required for metabolomic studies, improved reverse-phase high-performance liquid chromatography-mass spectrometry (RPHPLC-MS) methods have been recently reported for large-scale screening of metabolic phenotypes. However, these methods focus on the direct analysis of underivatized amino acids and, therefore, problems associated with insufficient retention and resolution are observed due to the hydrophilic nature of amino acids. It is well known that derivatization methods render amino acids more amenable for reverse phase chromatographic analysis by introducing highly-hydrophobic tags in their carboxylic acid or amino functional group. Therefore, an analytical platform that combines the 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC) pre-column derivatization method with ultra performance liquid chromatography-electrospray ionization-tandem mass spectrometry (UPLC-ESI-MS/MS) is presented in this article. For numerous reasons typical amino acid derivatization methods would be inadequate for large scale metabolic projects. However, AQC derivatization is a simple, rapid and reproducible way of obtaining stable amino acid adducts amenable for UPLC-ESI-MS/MS and the applicability of the method for high-throughput metabolomic analysis in Arabidopsis thaliana is demonstrated in this study. Overall, the major advantages offered by this amino acid analysis method include high-throughput, enhanced sensitivity and selectivity; characteristics that showcase its utility for the rapid screening of the preselected plant metabolites without compromising the quality of the metabolic data. The presented method enabled thirty-eight metabolites (proteinogenic amino acids and related compounds) to be analyzed within 10 min with detection limits down to 1.02 × 10−11 M (i.e., atomole level on column), which represents an improved sensitivity of 1 to 5 orders of magnitude compared to existing methods. Our UPLC-ESI-MS/MS method is one of the seven analytical platforms used by the Arabidopsis Metabolomics Consortium. The amino acid dataset obtained by analysis of Arabidopsis T-DNA mutant stocks with our platform is captured and open to the public in the web portal PlantMetabolomics.org. The analytical platform herein described could find important applications in other studies where the rapid, high-throughput and sensitive assessment of low abundance amino acids in complex biosamples is necessary. PMID:24957640

  13. LC/MS/MS analysis of the endogenous dimethyltryptamine hallucinogens, their precursors, and major metabolites in rat pineal gland microdialysate.

    PubMed

    Barker, Steven A; Borjigin, Jimo; Lomnicka, Izabela; Strassman, Rick

    2013-12-01

    We report a qualitative liquid chromatography-tandem mass spectrometry (LC/MS/MS) method for the simultaneous analysis of the three known N,N-dimethyltryptamine endogenous hallucinogens, their precursors and metabolites, as well as melatonin and its metabolic precursors. The method was characterized using artificial cerebrospinal fluid (aCSF) as the matrix and was subsequently applied to the analysis of rat brain pineal gland-aCSF microdialysate. The method describes the simultaneous analysis of 23 chemically diverse compounds plus a deuterated internal standard by direct injection, requiring no dilution or extraction of the samples. The results demonstrate that this is a simple, sensitive, specific and direct approach to the qualitative analysis of these compounds in this matrix. The protocol also employs stringent MS confirmatory criteria for the detection and confirmation of the compounds examined, including exact mass measurements. The excellent limits of detection and broad scope make it a valuable research tool for examining the endogenous hallucinogen pathways in the central nervous system. We report here, for the first time, the presence of N,N-dimethyltryptamine in pineal gland microdialysate obtained from the rat. Copyright © 2013 John Wiley & Sons, Ltd.

  14. Quantitative proteomics analysis using 2D-PAGE to investigate the effects of cigarette smoke and aerosol of a prototypic modified risk tobacco product on the lung proteome in C57BL/6 mice.

    PubMed

    Elamin, Ashraf; Titz, Bjoern; Dijon, Sophie; Merg, Celine; Geertz, Marcel; Schneider, Thomas; Martin, Florian; Schlage, Walter K; Frentzel, Stefan; Talamo, Fabio; Phillips, Blaine; Veljkovic, Emilija; Ivanov, Nikolai V; Vanscheeuwijck, Patrick; Peitsch, Manuel C; Hoeng, Julia

    2016-08-11

    Smoking is associated with several serious diseases, such as lung cancer and chronic obstructive pulmonary disease (COPD). Within our systems toxicology framework, we are assessing whether potential modified risk tobacco products (MRTP) can reduce smoking-related health risks compared to conventional cigarettes. In this article, we evaluated to what extent 2D-PAGE/MALDI MS/MS (2D-PAGE) can complement the iTRAQ LC-MS/MS results from a previously reported mouse inhalation study, in which we assessed a prototypic MRTP (pMRTP). Selected differentially expressed proteins identified by both LC-MS/MS and 2D-PAGE approaches were further verified using reverse-phase protein microarrays. LC-MS/MS captured the effects of cigarette smoke (CS) on the lung proteome more comprehensively than 2D-PAGE. However, an integrated analysis of both proteomics data sets showed that 2D-PAGE data complement the LC-MS/MS results by supporting the overall trend of lower effects of pMRTP aerosol than CS on the lung proteome. Biological effects of CS exposure supported by both methods included increases in immune-related, surfactant metabolism, proteasome, and actin cytoskeleton protein clusters. Overall, while 2D-PAGE has its value, especially as a complementary method for the analysis of effects on intact proteins, LC-MS/MS approaches will likely be the method of choice for proteome analysis in systems toxicology investigations. Quantitative proteomics is anticipated to play a growing role within systems toxicology assessment frameworks in the future. To further understand how different proteomics technologies can contribute to toxicity assessment, we conducted a quantitative proteomics analysis using 2D-PAGE and isobaric tag-based LC-MS/MS approaches and compared the results produced from the 2 approaches. Using a prototypic modified risk tobacco product (pMRTP) as our test item, we show compared with cigarette smoke, how 2D-PAGE results can complement and support LC-MS/MS data, demonstrating the much lower effects of pMRTP aerosol than cigarette smoke on the mouse lung proteome. The combined analysis of 2D-PAGE and LC-MS/MS data identified an effect of cigarette smoke on the proteasome and actin cytoskeleton in the lung. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  15. Integration of an In Situ MALDI-Based High-Throughput Screening Process: A Case Study with Receptor Tyrosine Kinase c-MET.

    PubMed

    Beeman, Katrin; Baumgärtner, Jens; Laubenheimer, Manuel; Hergesell, Karlheinz; Hoffmann, Martin; Pehl, Ulrich; Fischer, Frank; Pieck, Jan-Carsten

    2017-12-01

    Mass spectrometry (MS) is known for its label-free detection of substrates and products from a variety of enzyme reactions. Recent hardware improvements have increased interest in the use of matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) MS for high-throughput drug discovery. Despite interest in this technology, several challenges remain and must be overcome before MALDI-MS can be integrated as an automated "in-line reader" for high-throughput drug discovery. Two such hurdles include in situ sample processing and deposition, as well as integration of MALDI-MS for enzymatic screening assays that usually contain high levels of MS-incompatible components. Here we adapt our c-MET kinase assay to optimize for MALDI-MS compatibility and test its feasibility for compound screening. The pros and cons of the Echo (Labcyte) as a transfer system for in situ MALDI-MS sample preparation are discussed. We demonstrate that this method generates robust data in a 1536-grid format. We use the MALDI-MS to directly measure the ratio of c-MET substrate and phosphorylated product to acquire IC50 curves and demonstrate that the pharmacology is unaffected. The resulting IC50 values correlate well between the common label-based capillary electrophoresis and the label-free MALDI-MS detection method. We predict that label-free MALDI-MS-based high-throughput screening will become increasingly important and more widely used for drug discovery.

  16. A Simple and Sensitive LC-MS/MS Method for the Determination of Free 8-Hydroxy-2'-Deoxyguanosine in Human Urine

    NASA Technical Reports Server (NTRS)

    Wang, Zuwei; Smith, Scott M.

    2016-01-01

    Urinary free 8-hydroxy-2'-deoxyguanosine (8OHdG), an oxidized product of DNA, and is frequently chosen as a biomarker of oxidative stress in humans, including studies of oxidative DNA damage during space flight. It is challenging to accurately and efficiently quantify urinary free 8OHdG in large scale human studies. LC-MS/MS is emerging as a preferable analytical technique owing its high sensitivity, selectivity and efficiency, compared to some traditional methods such as ELISA and HPLC. A simple and sensitive LC-MS/MS method has been developed for the determination of free 8OHdG in human urine. Sample preparation was done by solid phase extraction with a Waters Oasis HLB 96 well plate. A Waters Alliance 2795 HT Separation Module combined with a Quattro Micro tandem mass spectrometer was used as the LC-MS/MS system. The runtime of one injection can be less than 5 minutes using a reversed phase C18 column and an isocratic flow of methanol/water. ESI positive ions were quantified in the multiple reaction modes (MRM) using m/z 284 yields 168 for 8OHdG and m/z 289 yields173 for stable isotope labeled internal standard [(15)N5] 8OHdG. With this method for 8OHdG, a lower limit of quantitation of 1.0 nM (0.28 ng/mL) has been achieved using 100 microliter urine sample. The analytical range is between 1.0 and 100 nM with a correlation coefficient greater than or equal to 0.99. Good reproducibility can be obtained with intra-assay and inter-assay CVs less than or equal to 10% for 8OHdG spiked urine QC samples. This method can be used in high-throughput routine analysis of free 8OHdG in human urine.

  17. Detection and identification of 700 drugs by multi-target screening with a 3200 Q TRAP LC-MS/MS system and library searching.

    PubMed

    Dresen, S; Ferreirós, N; Gnann, H; Zimmermann, R; Weinmann, W

    2010-04-01

    The multi-target screening method described in this work allows the simultaneous detection and identification of 700 drugs and metabolites in biological fluids using a hybrid triple-quadrupole linear ion trap mass spectrometer in a single analytical run. After standardization of the method, the retention times of 700 compounds were determined and transitions for each compound were selected by a "scheduled" survey MRM scan, followed by an information-dependent acquisition using the sensitive enhanced product ion scan of a Q TRAP hybrid instrument. The identification of the compounds in the samples analyzed was accomplished by searching the tandem mass spectrometry (MS/MS) spectra against the library we developed, which contains electrospray ionization-MS/MS spectra of over 1,250 compounds. The multi-target screening method together with the library was included in a software program for routine screening and quantitation to achieve automated acquisition and library searching. With the help of this software application, the time for evaluation and interpretation of the results could be drastically reduced. This new multi-target screening method has been successfully applied for the analysis of postmortem and traffic offense samples as well as proficiency testing, and complements screening with immunoassays, gas chromatography-mass spectrometry, and liquid chromatography-diode-array detection. Other possible applications are analysis in clinical toxicology (for intoxication cases), in psychiatry (antidepressants and other psychoactive drugs), and in forensic toxicology (drugs and driving, workplace drug testing, oral fluid analysis, drug-facilitated sexual assault).

  18. Development and validation of sensitive LC/MS/MS method for quantitative bioanalysis of levonorgestrel in rat plasma and application to pharmacokinetics study.

    PubMed

    Ananthula, Suryatheja; Janagam, Dileep R; Jamalapuram, Seshulatha; Johnson, James R; Mandrell, Timothy D; Lowe, Tao L

    2015-10-15

    Rapid, sensitive, selective and accurate LC/MS/MS method was developed for quantitative determination of levonorgestrel (LNG) in rat plasma and further validated for specificity, linearity, accuracy, precision, sensitivity, matrix effect, recovery efficiency and stability. Liquid-liquid extraction procedure using hexane:ethyl acetate mixture at 80:20 v:v ratio was employed to efficiently extract LNG from rat plasma. Reversed phase Luna column C18(2) (50×2.0mm i.d., 3μM) installed on a AB SCIEX Triple Quad™ 4500 LC/MS/MS system was used to perform chromatographic separation. LNG was identified within 2min with high specificity. Linear calibration curve was drawn within 0.5-50ng·mL(-1) concentration range. The developed method was validated for intra-day and inter-day accuracy and precision whose values fell in the acceptable limits. Matrix effect was found to be minimal. Recovery efficiency at three quality control (QC) concentrations 0.5 (low), 5 (medium) and 50 (high) ng·mL(-1) was found to be >90%. Stability of LNG at various stages of experiment including storage, extraction and analysis was evaluated using QC samples, and the results showed that LNG was stable at all the conditions. This validated method was successfully used to study the pharmacokinetics of LNG in rats after SubQ injection, providing its applicability in relevant preclinical studies. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Quantification of isoflavones in coffee by using solid phase extraction (SPE) and high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS).

    PubMed

    Caprioli, Giovanni; Navarini, Luciano; Cortese, Manuela; Ricciutelli, Massimo; Torregiani, Elisabetta; Vittori, Sauro; Sagratini, Gianni

    2016-09-01

    A new method for extracting isoflavones from espresso coffee (EC) was coupled with high-performance liquid chromatography-tandem mass spectrometry (MS/MS) for the first time to analyse five isoflavones, which included both a glycosilated form, genistin and the aglycons daidzein, genistein, formononetin and biochanin A. Isoflavones were extracted from coffee samples using methanol, stored in a freezer overnight to precipitate proteic or lipidic residues and purified on SPE C18 cartridges before high-performance liquid chromatography-MS/MS analysis. The recovery percentages obtained by spiking the matrix at concentrations of 10 and 100 µg l(-1) with a standard mixture of isoflavones were in the range of 70 to 104%. The limits of detection and limits of quantification were in the range of 0.015-0.3 µg l(-1) and 0.05-1 µg l(-1) , respectively. Once validated, the method was used to analyze the concentrations of isoflavones in six ECs and ten ground coffee samples. Only formononetin and biochanin A were found, and their respective concentrations ranged from 0.36 to 0.41 µg l(-1) and from 0.58 to 3.26 µg l(-1) in ECs and from 0.36 to 4.27 µg kg(-1) and from 0.71 to 3.95 µg kg(-1) in ground coffees. This method confirms the high specificity and selectivity of MS/MS systems for detecting bioactives in complex matrices such as coffee.Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  20. Urinary iodine: comparison of a simple method for its determination in microplates with measurement by inductively-coupled plasma mass spectrometry

    PubMed Central

    Haap, Michael; Roth, Heinz Jürgen; Huber, Thomas; Dittmann, Helmut; Wahl, Richard

    2017-01-01

    The aim of our study was to develop and validate an inexpensive, rapid, easy to use quantitative method to determine urinary iodine without major procurement costs for equipment. The rationale behind introducing this method is the increasing demand for urinary iodine assessments. Our study included 103 patients (76 female, 27 male), age (arithmetic mean) 52 ± 17.3 years. Urinary iodine was determined in microplates by a modification of the Sandell-Kolthoff reaction. The results were compared with inductively-coupled plasma mass spectrometry (ICP-MS) for iodine, considered as reference method. Geometric mean of urinary iodine determined by the Sandell-Kolthoff reaction method was 62.69 μg/l (95% confidence interval 53.16–73.92) whereas by the ICP-MS method it was 65.53 μg/l (95% confidence interval 54.77–78.41). Passing-Bablok regression equations for both methods gave y = 3.374 + 0.873x (y: Sandell-Kolthoff method, x: ICP-MS). Spearman´s correlation coefficient was 0.981, indicating a very high degree of agreement between the two methods. Bland-Altman plots showed no significant systematic difference between the two methods. The modified Sandell-Kolthoff method using microtiter plate technique presented here is a simple, inexpensive semi-automated method to determine urinary iodine with very little toxic waste. Comparison with the ICP-MS-technique yielded a good agreement between the two methods. PMID:28045077

  1. A pilot mixed-methods evaluation of MS INFoRm: a self-directed fatigue management resource for individuals with multiple sclerosis.

    PubMed

    Akbar, Nadine; Turpin, Karen; Petrin, Julie; Smyth, Penny; Finlayson, Marcia

    2018-06-01

    Fatigue management interventions for individuals with multiple sclerosis (MS) often feature structured programmes requiring repeated, in-person attendance that is not possible for all individuals. We sought to determine whether MS INFoRm, a self-directed fatigue management resource for individuals with MS, was worth further, more rigorous evaluation. Our indicators of worthiness were actual use of the resource by participants over 3 months, reductions in fatigue impact and increases in self-efficacy, and participant reports of changes in fatigue management knowledge and behaviours. This was a single-group, mixed-methods, before-after pilot study in individuals with MS reporting mild to moderate fatigue. Thirty-five participants were provided with MS INFoRm by a USB flash drive to use at home for 3 months, on their own volition. Twenty-three participants completed all standardized questionnaires, semi-structured interviews and study process measures. Participants reported actively using MS INFoRm over the 3-month study period (median total time spent using MS INFoRm=315 min) as well as significantly lower overall fatigue impact (Modified Fatigue Impact Scale: t=2.6, P=0.01), increased knowledge of MS fatigue (z=-2.8, P=0.01) and greater confidence in managing MS fatigue (z=-3.3, P=0.001). Individuals with significant reductions in fatigue impact also reported behavioural changes including tracking fatigue, better communication with others, greater awareness, improved quality of life and being more proactive. This study provides evidence that further rigorous evaluation of MS INFoRm, a self-directed resource for managing fatigue, is worth pursuing.

  2. Broad-Range Detection of Microorganisms Directly from Bronchoalveolar Lavage Specimens by PCR/Electrospray Ionization-Mass Spectrometry

    PubMed Central

    Ullberg, Måns; Lüthje, Petra; Mölling, Paula; Strålin, Kristoffer

    2017-01-01

    The clinical demand on rapid microbiological diagnostic is constantly increasing. PCR coupled to electrospray ionization-mass spectrometry, PCR/ESI-MS, offers detection and identification of over 750 bacteria and Candida species directly from clinical specimens within 6 hours. In this study, we investigated the clinical performance of the IRIDICA BAC LRT Assay for detection of bacterial pathogens in 121 bronchoalveolar lavage (BAL) samples that were received consecutively at our bacterial laboratory for BAL culture. Commensal or pathogenic microorganisms were detected in 118/121 (98%) BAL samples by PCR/ESI-MS, while in 104/121 (86%) samples by routine culture (P<0.01). Detection of potentially pathogenic microorganisms by PCR/ESI-MS was evaluated in comparison with conventional culture-based or molecular methods. The agreement between positive findings was overall good. Most Staphylococcus aureus-positive PCR/ESI-MS results were confirmed by culture or species-specific PCR (27/33, 82%). The identity of Streptococcus pneumoniae could however be confirmed for only 6/17 (35%) PCR/ESI-MS-positive samples. Non-cultivable and fastidious pathogens, which were not covered by standard culture procedures were readily detected by PCR/ESI-MS, including Legionella pneumophila, Bordetella pertussis, Norcadia species and Mycoplasma pneumoniae. In conclusion, PCR/ESI-MS detected a broad range of potential pathogens with equal or superior sensitivity compared to conventional methods within few hours directly from BAL samples. This novel method might thus provide a relevant tool for diagnostics in critically ill patients. PMID:28085931

  3. 77 FR 67282 - Dinotefuran; Pesticide Tolerances for Emergency Exemptions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-09

    ... performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) method is available. For the determination of residues of dinotefuran only, an HPLC/ultraviolet (UV) detection method is available. For the determination of only the metabolites (DN and UF), HPLC/MS and HPLC/MS/MS methods are available. These methods...

  4. Measurement of trace levels of antibiotics in river water using on-line enrichment and triple-quadrupole LC-MS/MS.

    PubMed

    Dinh, Quoc Tuc; Alliot, Fabrice; Moreau-Guigon, Elodie; Eurin, Joëlle; Chevreuil, Marc; Labadie, Pierre

    2011-09-15

    This study presents the development of an automated on-line solid phase extraction (SPE)-liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of 23 antibiotics in environmental water samples. After optimisation of LC-MS/MS conditions, SPE parameters such as sorbent type, sample pH or sample volume were optimised. Antibiotic recoveries ranged from 64% to 98% and compared favourably with those achieved using off-line SPE. Limits of detection were in the range 0.5-13.7 ng L(-1). This on-line SPE-LC-MS/MS procedure was applied to the analysis of water samples taken in three rivers within the Seine River basin, near Paris (France). The obtained results revealed the occurrence of 12 antibiotics, including tylosin, erythromycin, tetracycline, amoxicillin, trimethoprim, sulfamethoxazole, oxolinic acid, flumequine, norfloxacin, ciprofloxacin, ofloxacin, and vancomycin (2-1435 ng L(-1)). Copyright © 2011 Elsevier B.V. All rights reserved.

  5. On the Ionization and Ion Transmission Efficiencies of Different ESI-MS Interfaces

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cox, Jonathan T.; Marginean, Ioan; Smith, Richard D.

    2014-09-30

    It is well known that the achievable sensitivity of electrospray ionization mass spectrometry (ESI-MS) is largely determined by the ionization efficiency in the ESI source and ion transmission efficiency through the ESI-MS interface. In this report we systematically study the ion transmission and ionization efficiencies in different ESI-MS interface configurations. The configurations under investigation include a single emitter/single inlet capillary, single emitter/multi-inlet capillary, and a subambient pressure ionization with nanoelectrospray (SPIN) MS interfaces with a single emitter and an emitter array, respectively. We present an effective method to evaluate the overall ion utilization efficiency of an ESI-MS interface by measuringmore » the total gas phase ion current transmitted through the interface and correlating it to the observed ion abundance measured in the corresponding mass spectrum. Our experimental results suggest that the overall ion utilization efficiency in the SPIN-MS interface configurations is better than that in the inlet capillary based ESI-MS interface configurations.« less

  6. Quantification of steroid hormones in human serum by liquid chromatography-high resolution tandem mass spectrometry.

    PubMed

    Matysik, Silke; Liebisch, Gerhard

    2017-12-01

    A limited specificity is inherent to immunoassays for steroid hormone analysis. To improve selectivity mass spectrometric analysis of steroid hormones by liquid chromatography-tandem mass spectrometry (LC-MS/MS) has been introduced in the clinical laboratory over the past years usually with low mass resolution triple-quadrupole instruments or more recently by high resolution mass spectrometry (HR-MS). Here we introduce liquid chromatography-high resolution tandem mass spectrometry (LC-MS/HR-MS) to further increase selectivity of steroid hormone quantification. Application of HR-MS demonstrates an enhanced selectivity compared to low mass resolution. Separation of isobaric interferences reduces background noise and avoids overestimation. Samples were prepared by automated liquid-liquid extraction with MTBE. The LC-MS/HR-MS method using a quadrupole-Orbitrap analyzer includes eight steroid hormones i.e. androstenedione, corticosterone, cortisol, cortisone, 11-deoxycortisol, 17-hydroxyprogesterone, progesterone, and testosterone. It has a run-time of 5.3min and was validated according to the U.S. Food and Drug Administration (FDA) and the European Medicines Agency (EMA) guidelines. For most of the analytes coefficient of variation were 10% or lower and LOQs were determined significantly below 1ng/ml. Full product ion spectra including accurate masses substantiate compound identification by matching their masses and ratios with authentic standards. In summary, quantification of steroid hormones by LC-MS/HR-MS is applicable for clinical diagnostics and holds also promise for highly selective quantification of other small molecules. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. The selective determination of sulfates, sulfonates and phosphates in urine by CE-MS.

    PubMed

    Bunz, Svenja-Catharina; Weinmann, Wolfgang; Neusüss, Christian

    2010-04-01

    Metabolite identification and metabolite profiling are of major importance in the pharmaceutical and clinical context. However, highly polar and ionic substances are rarely included as analytical tools are missing. In this study, we present a new method for the determination of urinary sulfates, sulfonates, phosphates and other anions of strong acids. The method comprises a CE separation using an acidic BGE (pH

  8. Mycotoxin analysis: an update.

    PubMed

    Krska, Rudolf; Schubert-Ullrich, Patricia; Molinelli, Alexandra; Sulyok, Michael; MacDonald, Susan; Crews, Colin

    2008-02-01

    Mycotoxin contamination of cereals and related products used for feed can cause intoxication, especially in farm animals. Therefore, efficient analytical tools for the qualitative and quantitative analysis of toxic fungal metabolites in feed are required. Current methods usually include an extraction step, a clean-up step to reduce or eliminate unwanted co-extracted matrix components and a separation step with suitably specific detection ability. Quantitative methods of analysis for most mycotoxins use immunoaffinity clean-up with high-performance liquid chromatography (HPLC) separation in combination with UV and/or fluorescence detection. Screening of samples contaminated with mycotoxins is frequently performed by thin layer chromatography (TLC), which yields qualitative or semi-quantitative results. Nowadays, enzyme-linked immunosorbent assays (ELISA) are often used for rapid screening. A number of promising methods, such as fluorescence polarization immunoassays, dipsticks, and even newer methods such as biosensors and non-invasive techniques based on infrared spectroscopy, have shown great potential for mycotoxin analysis. Currently, there is a strong trend towards the use of multi-mycotoxin methods for the simultaneous analysis of several of the important Fusarium mycotoxins, which is best achieved by LC-MS/MS (liquid chromatography with tandem mass spectrometry). This review focuses on recent developments in the determination of mycotoxins with a special emphasis on LC-MS/MS and emerging rapid methods.

  9. Development and optimisation of an HPLC-DAD-ESI-Q-ToF method for the determination of phenolic acids and derivatives.

    PubMed

    Restivo, Annalaura; Degano, Ilaria; Ribechini, Erika; Colombini, Maria Perla

    2014-01-01

    A method for the HPLC-MS/MS analysis of phenols, including phenolic acids and naphtoquinones, using an amide-embedded phase column was developed and compared to the literature methods based on classical C18 stationary phase columns. RP-Amide is a recently developed polar embedded stationary phase, whose wetting properties mean that up to 100% water can be used as an eluent. The increased retention and selectivity for polar compounds and the possibility of working in 100% water conditions make this column particularly interesting for the HPLC analysis of phenolic acids and derivatives. In this study, the chromatographic separation was optimised on an HPLC-DAD, and was used to separate 13 standard phenolic acids and derivatives. The method was validated on an HPLC-ESI-Q-ToF. The acquisition was performed in negative polarity and MS/MS target mode. Ionisation conditions and acquisition parameters for the Q-ToF detector were investigated by working on collision energies and fragmentor potentials. The performance of the method was fully evaluated on standards. Moreover, several raw materials containing phenols were analysed: walnut, gall, wine, malbec grape, French oak, red henna and propolis. Our method allowed us to characterize the phenolic composition in a wide range of matrices and to highlight possible matrix effects.

  10. Development and validation of an HPLC–MS/MS method to determine clopidogrel in human plasma

    PubMed Central

    Liu, Gangyi; Dong, Chunxia; Shen, Weiwei; Lu, Xiaopei; Zhang, Mengqi; Gui, Yuzhou; Zhou, Qinyi; Yu, Chen

    2015-01-01

    A quantitative method for clopidogrel using online-SPE tandem LC–MS/MS was developed and fully validated according to the well-established FDA guidelines. The method achieves adequate sensitivity for pharmacokinetic studies, with lower limit of quantifications (LLOQs) as low as 10 pg/mL. Chromatographic separations were performed on reversed phase columns Kromasil Eternity-2.5-C18-UHPLC for both methods. Positive electrospray ionization in multiple reaction monitoring (MRM) mode was employed for signal detection and a deuterated analogue (clopidogrel-d4) was used as internal standard (IS). Adjustments in sample preparation, including introduction of an online-SPE system proved to be the most effective method to solve the analyte back-conversion in clinical samples. Pooled clinical samples (two levels) were prepared and successfully used as real-sample quality control (QC) in the validation of back-conversion testing under different conditions. The result showed that the real samples were stable in room temperature for 24 h. Linearity, precision, extraction recovery, matrix effect on spiked QC samples and stability tests on both spiked QCs and real sample QCs stored in different conditions met the acceptance criteria. This online-SPE method was successfully applied to a bioequivalence study of 75 mg single dose clopidogrel tablets in 48 healthy male subjects. PMID:26904399

  11. Measurement of bone marrow lesions by MR imaging in knee osteoarthritis using quantitative segmentation methods--a reliability and sensitivity to change analysis.

    PubMed

    Nielsen, Flemming K; Egund, Niels; Peters, David; Jurik, Anne Grethe

    2014-12-20

    Longitudinal assessment of bone marrow lesions (BMLs) in knee osteoarthritis (KOA) by MRI is usually performed using semi-quantitative grading methods. Quantitative segmentation methods may be more sensitive to detect change over time. The purpose of this study was to evaluate and compare the validity and sensitivity to detect changes of two quantitative MR segmentation methods for measuring BMLs in KOA, one computer assisted (CAS) and one manual (MS) method. Twenty-two patients with KOA confined to the medial femoro-tibial compartment obtained MRI at baseline and follow-up (median 334 days in between). STIR, T1 and fat saturated T1 post-contrast sequences were obtained using a 1.5 T system. The 44 sagittal STIR sequences were assessed independently by two readers for quantification of BML. The signal intensities (SIs) of the normal bone marrow in the lateral femoral condyles and tibial plateaus were used as threshold values. The volume of bone marrow with SIs exceeding the threshold values (BML) was measured in the medial femoral condyle and tibial plateau and related to the total volume of the condyles/plateaus.The 95% limits of agreement at baseline were used to determine the sensitivity to change. The mean threshold values of CAS and MS were almost identical but the absolute and relative BML volumes differed being 1319 mm3/10% and 1828 mm3/15% in the femur and 941 mm3/7% and 2097 mm3/18% in the tibia using CAS and MS, respectively. The BML volumes obtained by CAS and MS were significantly correlated but the tissue changes measured were different. The volume of voxels exceeding the threshold values was measured by CAS whereas MS included intervening voxels with normal SI.The 95% limits of agreement were narrower by CAS than by MS; a significant change of relative BML by CAS was outside the limits of -2.0%-4.7% whereas the limits by MS were -6.9%-8.2%. The BML changed significantly in 13 knees using CAS and in 10 knees by MS. CAS was a reliable method for measuring BML and more sensitive to detect changes over time than MS. The BML volumes measured by the two methods differed but were significantly correlated.

  12. Experiences of patients with multiple sclerosis from group counseling.

    PubMed

    Mazaheri, Mina; Fanian, Nasrin; Zargham-Boroujeni, Ali

    2011-01-01

    Group counseling is one of the most important methods in somatic and psychological rehabilitation of the multiple sclerosis (M.S.) patients. Knowing these patients' experiences, feelings, believes and emotion based on learning in group is necessary to indicate the importance of group discussion on quality of life of the patients. This study was done to achieve experiences of M.S. patients from group training. This was a qualitative study using phenomenological method. The samples were selected using purposeful sampling. Ten patients from M.S. society who had passed group training were included in the study. The group training was done through seven sessions weekly and voluntarily. The participants were interviewed using in-depth interview. The average time of each interview was between 30-50 minutes which has been recorded digitally and moved to a compact disc to transcribe and analysis. The data analyzed using 7-step Colaizzi method. The data were transformed into 158 codes, 12 sub-concepts and 4 main concepts including emotional consequences, communication, quality of life and needs. M.S can lead to multiple problems in patients such as somatic, behavioral, emotional and social disorders. Group psychotherapy is one of the methods which can decrease these problems and improve rehabilitation of the patients. Group discussion helps patients to overcome adverse feelings, behaviors and thoughts and guides them to move in a meaningful life. It also can improve quality of life and mental health of the patients.

  13. Ion/Neutral, Ion/Electron, Ion/Photon, and Ion/Ion Interactions in Tandem Mass Spectrometry: Do we need them all? Are they enough?

    PubMed Central

    McLuckey, Scott A.; Mentinova, Marija

    2011-01-01

    A range of strategies and tools has been developed to facilitate the determination of primary structures of analyte molecules of interest via tandem mass spectrometry (MS/MS). The two main factors that determine the primary structural information present in an MS/MS spectrum are the type of ion generated from the analyte molecule and the dissociation method. The ion-type subjected to dissociation is determined by the ionization method/conditions and ion transformation processes that might take place after initial gas-phase ion formation. Furthermore, the range of analyte-related ion types can be expanded via derivatization reactions prior to mass spectrometry. Dissociation methods include those that simply alter the population of internal states of the mass-selected ion (i.e., activation methods like collision-induced dissociation) as well as processes that rely on transformation of the ion-type prior to dissociation (e.g., electron capture dissociation). A variety of ionic interactions has been studied for the purpose of ion dissociation and ion transformation that include ion/neutral, ion/photon, ion/electron, and ion/ion interactions. A wide range of phenomena has been observed, many of which have been explored/developed as means for structural analysis. The techniques arising from these phenomena are discussed within the context of the elements of structure determination in tandem mass spectrometry, viz., ion-type definition and dissociation. Unique aspects of the various ion interactions are emphasized along with any barriers to widespread implementation. PMID:21472539

  14. Multi-residue method for the determination of pesticides and pesticide metabolites in honeybees by liquid and gas chromatography coupled with tandem mass spectrometry--Honeybee poisoning incidents.

    PubMed

    Kiljanek, Tomasz; Niewiadowska, Alicja; Semeniuk, Stanisław; Gaweł, Marta; Borzęcka, Milena; Posyniak, Andrzej

    2016-02-26

    A method for the determination of 200 pesticides and pesticide metabolites in honeybee samples has been developed and validated. Almost 98% of compounds included in this method are approved to use within European Union, as active substances of plant protection products or veterinary medicinal products used by beekeepers to control mites Varroa destructor in hives. Many significant metabolites, like metabolites of imidacloprid, thiacloprid, fipronil, methiocarb and amitraz, are also possible to detect. The sample preparation was based on the buffered QuEChERS method. Samples of bees were extracted with acetonitrile containing 1% acetic acid and then subjected to clean-up by dispersive solid phase extraction (dSPE) using a new Z-Sep+ sorbent and PSA. The majority of pesticides, including neonicotionoids and their metabolites, were analyzed by liquid chromatography tandem mass spectrometry (LC-MS/MS) but some of pesticides, especially pyrethroid insecticides, were analyzed by gas chromatography tandem mass spectrometry (GC-MS/MS). The procedure was validated according to the Guidance document SANCO/12571/2013 at four concentration levels: 1, 5, 10 and 100 ng/g bees and verified in the international proficiency test. The analysis of bee samples spiked at the limit of quantification (LOQ) showed about 98% mean recovery value (trueness) and 97% of analytes showed recovery in the required range of 70-120% and RSDr (precision) below 20%. Linearity and matrix effects were also established. The LOQs of pesticides were in the range of 1-100 ng/g. The developed method allows determination of insecticides at concentrations of 10 ng/g or less, except abamectin and tebufenozide. LOQ values are lower than the median lethal doses LD50 for bees. The method was used to investigate more than 70 honeybee poisoning incidents. Data about detected pesticides and their metabolites are included. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. A novel mass spectrometric method for formaldehyde in children's personal-care products and water via derivatization with acetylacetone.

    PubMed

    Backe, Will J

    2017-06-30

    New legislation in the state of Minnesota prohibits the sale of children's personal-care products (PCPs) that contain more than 500 ng/mg formaldehyde. Previous attempts to quantify formaldehyde in PCPs use nonspecific derivatization procedures that employ harsh reagents and/or nonspecific detection. Derivatization of formaldehyde by acetylacetone occurs under mild conditions and is specific for formaldehyde but it has not been investigated using high-performance liquid chromatography/tandem mass-spectrometry (HPLC/MS/MS). To determine formaldehyde, PCPs were dissolved and then interferences were minimized by graphitized-carbon solid-phase extraction. Formaldehyde was derivatized to 3,5-diacetyl-1,4-dihydrolutidine (DDL) using an acetylacetone solution. Post-derivatization, samples were diluted and analyzed by HPLC/MS/MS. Quantification was performed by isotopic dilution. Product-ion spectra were acquired for DDL and D 12 -DDL. The mass shifts between the two product-ion spectra were used to assign fragment structures. To confirm molecular formulas, high-resolution accurate-mass analysis of the DDL product ions was performed by quadrupole time-of-flight MS. Structures were proposed for all product ions of DDL above 10% relative intensity. Method accuracy ranged between 96-104% for all matrices at all concentrations tested. Method precision was less than 4% relative standard deviation. The reporting limit was 10 ng/mg in PCPs and 100 μg/L in water. Twenty children's PCPs were tested to demonstrate the method and formaldehyde was reported in five from 23-1500 ng/mg. Of those five, two samples contained formaldehyde above the Minnesota regulatory limit. The developed method allows for the accurate quantification of formaldehyde in PCPs at levels below those required by a new regulation on children's products in Minnesota. The method includes a derivatization procedure that is newly adapted to HPLC/MS/MS; therefore, structures were proposed for the product ions of the derivative (DDL). Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  16. Simultaneous quantification and identification of flavonoids, lignans, coumarin and amides in leaves of Zanthoxylum armatum using UPLC-DAD-ESI-QTOF-MS/MS.

    PubMed

    Bhatt, Vinod; Sharma, Sushila; Kumar, Neeraj; Sharma, Upendra; Singh, Bikram

    2017-01-05

    The current study presents isolation and characterization of twelve compounds including catechin (1), isovitexin (2), hesperidin (3), psoralin (4), eudesmin (5), kobusin (6), fargesin (7), sesamin (8), asarinin (9), planispine-A (10), α-sanshool (11) and vitexin (12), from the leaves of Zanthoxylum armatum. Further, two rapid and simple ultra performance liquid chromatography-diode array detection (UPLC-DAD) methods were developed for the simultaneous quantitative determination of isolated compounds from Z. armatum leaves. These analytical methods were validated for linearity, precision, accuracy, limit of detection (LOD) and limit of quantification (LOQ). The LOD and LOQ were in the range of 0.06-0.21μg/mL and 0.19-0.69μg/mL, respectively. The validated method was linear (R 2 ≥0.9906), precise in terms of peak area (intra-day RSDs <3.8% and inter-day RSDs <2.7%), and accurate (109.6-92.5%). This is the first report on the isolation and quantification of 1, 2, 4 and 12 in Z. armatum and 3 in Zanthoxylum genus. The methods: were successfully applied to assess the quality of samples collected from different locations of Himachal Pradesh during summer and winter season. The results demonstrated that flavonoids and furofuran lignans were the major constituents in Z. armatum leaves. The developed methods: were further applied for tandem electrospray ionization-mass spectrometry (UPLC-DAD-ESI-MS/MS) and total eighteen compounds were identified including phenolic acid, flavonoids, furofuran lignans, coumarin and isobutyl amides. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Determination of a steroid profile in heel prick blood using LC-MS/MS.

    PubMed

    Boelen, Anita; Ruiter, An F C; Claahsen-van der Grinten, Hedi L; Endert, Erik; Ackermans, Mariette T

    2016-01-01

    The aim of this study was to improve the sensitivity of the congenital adrenal hyperplasia (CAH) neonatal screening by including second-tier steroid profiling on a DBS using LC-MS. We developed a method to measure the steroid profile in DBS and established gestational age-specific reference ranges of cortisol, cortisone, 11-deoxycortisol, 21-deoxycortisol, 17-hydroxyprogesterone, testosterone, Δ4-androstenedione, corticosterone and 11-deoxycorticosterone using 450 heel prick samples of neonates, participating in the Dutch Screening Program. Analyzing 92 cards with a positive CAH screening showed that only 21-deoxycortisol was 100% specific for diagnosed CAH patients. Steroid precursors can be measured in DBS and we suggest to implement the method as a second tier testing for CAH in The Netherlands.

  18. Perceptual Measures of Speech from Individuals with Parkinson's Disease and Multiple Sclerosis: Intelligibility and beyond

    ERIC Educational Resources Information Center

    Sussman, Joan E.; Tjaden, Kris

    2012-01-01

    Purpose: The primary purpose of this study was to compare percent correct word and sentence intelligibility scores for individuals with multiple sclerosis (MS) and Parkinson's disease (PD) with scaled estimates of speech severity obtained for a reading passage. Method: Speech samples for 78 talkers were judged, including 30 speakers with MS, 16…

  19. Metabolic Syndrome and Serum Liver Enzymes Level at Patients with Type 2 Diabetes Mellitus

    PubMed Central

    Music, Miralem; Dervisevic, Amela; Pepic, Esad; Lepara, Orhan; Fajkic, Almir; Ascic-Buturovic, Belma; Tuna, Enes

    2015-01-01

    Objectives: The aim of this study was to evaluate liver function in patients with type 2 diabetes mellitus (T2DM) with and without metabolic syndrome (MS) by determining serum levels of gamma glutamyltransferase (GGT), alanine aminotransferase (ALT) and aspartate aminotransferase (AST). We also investigated correlation between levels of liver enzymes and some components of MS in both groups of patients. Methods: This cross-sectional study included 96 patients (age 47–83 years) with T2DM. All patients were divided according to the criteria of the National Cholesterol Education Program (NCEP) in two groups: 50 patients with T2 DM and MS (T2DM-MS) and 46 patients with T2DM without MS (T2DM-Non MS). The analysis included blood pressure monitoring and laboratory tests: fasting blood glucose (FBG), total lipoprotein cholesterol (TC), high-density lipoprotein cholesterol (HDL-C), triglyceride (TG), fibrinogen and liver enzymes: GGT, ALT and AST. T2DM-MS group included patients which had FBG ≥ 6,1 mmol/L, TG ≥ 1,7 mmol/L and blood pressure ≥ 130/85 mm Hg. Results: T2DM-MS patients had significant higher values of systolic blood pressure, diastolic blood pressure and medium arterial pressure compared to T2DM-Non MS patients. Serum levels of TC, TG, LDL-C, VLDL-C and FBG were significantly higher in the T2DM-MS group compared to the T2DM-Non MS group. Serum fibrinogen level and GGT level were significantly higher in patients with T2DM-MS compared to the serum fibrinogen level and GGT level in T2DM-Non MS patients. Mean serum AST and ALT level were higher, but not significantly, in patients with T2DM and MS compared to the patients with T2DM without MS. Significant negative correlations were observed between TC and AST (r= -0,28, p<0,05), as well as between TC and ALT level (r= -0,29, p<0,05) in T2DM-MS group of patients. Conclusion: These results suggest that patients with T2DM and MS have markedly elevated liver enzymes. T2DM and MS probably play a role in increasing the risk of liver injury. PMID:26543313

  20. Advanced Mass Spectrometric Methods for the Rapid and Quantitative Characterization of Proteomes

    DOE PAGES

    Smith, Richard D.

    2002-01-01

    Progress is reviewedmore » towards the development of a global strategy that aims to extend the sensitivity, dynamic range, comprehensiveness and throughput of proteomic measurements based upon the use of high performance separations and mass spectrometry. The approach uses high accuracy mass measurements from Fourier transform ion cyclotron resonance mass spectrometry (FTICR) to validate peptide ‘accurate mass tags’ (AMTs) produced by global protein enzymatic digestions for a specific organism, tissue or cell type from ‘potential mass tags’ tentatively identified using conventional tandem mass spectrometry (MS/MS). This provides the basis for subsequent measurements without the need for MS/ MS. High resolution capillary liquid chromatography separations combined with high sensitivity, and high resolution accurate FTICR measurements are shown to be capable of characterizing peptide mixtures of more than 10 5 components. The strategy has been initially demonstrated using the microorganisms Saccharomyces cerevisiae and Deinococcus radiodurans. Advantages of the approach include the high confidence of protein identification, its broad proteome coverage, high sensitivity, and the capability for stableisotope labeling methods for precise relative protein abundance measurements. Abbreviations : LC, liquid chromatography; FTICR, Fourier transform ion cyclotron resonance; AMT, accurate mass tag; PMT, potential mass tag; MMA, mass measurement accuracy; MS, mass spectrometry; MS/MS, tandem mass spectrometry; ppm, parts per million.« less

  1. Fast targeted analysis of 132 acidic and neutral drugs and poisons in whole blood using LC-MS/MS.

    PubMed

    Di Rago, Matthew; Saar, Eva; Rodda, Luke N; Turfus, Sophie; Kotsos, Alex; Gerostamoulos, Dimitri; Drummer, Olaf H

    2014-10-01

    The aim of this study was to develop an LC-MS/MS based screening technique that covers a broad range of acidic and neutral drugs and poisons by combining a small sample volume and efficient extraction technique with simple automated data processing. After protein precipitation of 100μL of whole blood, 132 common acidic and neutral drugs and poisons including non-steroidal anti-inflammatory drugs, barbiturates, anticonvulsants, antidiabetics, muscle relaxants, diuretics and superwarfarin rodenticides (47 quantitated, 85 reported as detected) were separated using a Shimadzu Prominence HPLC system with a C18 separation column (Kinetex XB-C18, 4.6mm×150mm, 5μm), using gradient elution with a mobile phase of 25mM ammonium acetate buffer (pH 7.5)/acetonitrile. The drugs were detected using an ABSciex(®) API 2000 LC-MS/MS system (ESI+ and -, MRM mode, two transitions per analyte). The method was fully validated in accordance with international guidelines. Quantification data obtained using one-point calibration compared favorably to that using multiple calibrants. The presented LC-MS/MS assay has proven to be applicable for determination of the analytes in blood. The fast and reliable extraction method combined with automated processing gives the opportunity for high throughput and fast turnaround times for forensic and clinical toxicology. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  2. Validation of an LC-MS/MS method for the quantification of choline-related compounds and phospholipids in foods and tissues.

    PubMed

    Xiong, Yeping; Zhao, Yuan-Yuan; Goruk, Sue; Oilund, Kirsten; Field, Catherine J; Jacobs, René L; Curtis, Jonathan M

    2012-12-12

    A hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC LC-MS/MS) method was developed and validated to simultaneously quantify six aqueous choline-related compounds and eight major phospholipids classes in a single run. HILIC chromatography was coupled to positive ion electrospray mass spectrometry. A combination of multiple scan modes including precursor ion scan, neutral loss scan and multiple reaction monitoring was optimized for the determination of each compound or class in a single LC/MS run. This work developed a simplified extraction scheme in which both free choline and related compounds along with phospholipids were extracted into a homogenized phase using chloroform/methanol/water (1:2:0.8) and diluted into methanol for the analysis of target compounds in a variety of sample matrices. The analyte recoveries were evaluated by spiking tissues and food samples with two isotope-labeled internal standards, PC-d(3) and Cho-d(3). Recoveries of between 90% and 115% were obtained by spiking a range of sample matrices with authentic standards containing all 14 of the target analytes. The precision of the analysis ranged from 1.6% to 13%. Accuracy and precision was comparable to that obtained by quantification of selected phospholipid classes using (31)P NMR. A variety of sample matrices including egg yolks, human diets and animal tissues were analyzed using the validated method. The measurements of total choline in selected foods were found to be in good agreement with values obtained from the USDA choline database. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Rapid screening of abused drugs by direct analysis in real time (DART) coupled to time-of-flight mass spectrometry (TOF-MS) combined with ion mobility spectrometry (IMS).

    PubMed

    Lian, Ru; Wu, Zhongping; Lv, Xiaobao; Rao, Yulan; Li, Haiyang; Li, Jinghua; Wang, Rong; Ni, Chunfang; Zhang, Yurong

    2017-10-01

    Increasing in cases involving drugs of abuse leads to heavy burden for law enforcement agencies, exacerbating demand for rapid screening technique. In this study, atmospheric pressure ionization technologies including direct analysis in real time (DART) ion source coupled to a time-of-flight mass spectrometer (DART-TOF-MS)as well asdopant-assisted positive photoionization ion mobility spectrometry (DAPP-IMS) without radioactivity were utilized together as the powerful analytical tool for the rapid screening and identification of 53 abused drugs.The limits of detection (LOD) were 0.05-2μg/mL when using DART-TOF-MS and 0.02-2μg when using DAPP-IMS which could satisfy the actual requirement in forensic science laboratory. The advantages of this method included fast response, high-throughput potential, high specificity, and minimal sample preparation. A screening library of reduced mobility (K 0 ), accurate mass of informative precursor ion ([M+H] + ) and fragment ions was established respectively by employing a bench-top DAPP-IMS and TOF-MS in-source collision induced dissociation (CID) mode. Then the standardized screening procedure was developed with criteria for the confirmation of positive result. A total of 50 seized drug samples provided by local forensic laboratory we reanalyzed to testify the utility of the method. This study suggests that a method combing DART-TOF-MS and DAPP-IMS is promising for the rapid screening and identification of abused drugs with minimal sample preparation and absence of chromatography. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Ultra pressure liquid chromatography-negative electrospray ionization mass spectrometry determination of twelve halobenzoquinones at ng/L levels in drinking water.

    PubMed

    Huang, Rongfu; Wang, Wei; Qian, Yichao; Boyd, Jessica M; Zhao, Yuli; Li, Xing-Fang

    2013-05-07

    We report here the characterization of twelve halobenzoquinones (HBQs) using electrospray ionization (ESI) high resolution quadrupole time-of-flight mass spectrometry. The high resolution negative ESI spectra of the twelve HBQs formed two parent ions, [M + H(+) + 2e(-)], and the radical M(-•). The intensities of these two parent ions are dependent on their chemical structures and on instrumental parameters such as the source temperature and flow rate. The characteristic ions of the HBQs were used to develop an ultra pressure liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method. At the UPLC flow rate (400 μL/min) and under the optimized ESI conditions, eleven HBQs showed the stable and abundant transitions [M + H(+) + 2e(-)] → X(-) (X(-) representing Cl(-), Br(-), or I(-)), while dibromo-dimethyl-benzoquinone (DBDMBQ) showed only the transition of M(-•) → Br(-). The UPLC efficiently separates all HBQs including some HBQ isomers, while the MS/MS offers exquisite limits of detection (LODs) at subng/mL levels for all HBQs except DBDMBQ. Combined with solid phase extraction (SPE), the method LOD is down to ng/L. The results from analysis of authentic samples demonstrated that the SPE-UPLC-MS/MS method is reliable, fast, and sensitive for the identification and quantification of the twelve HBQs in drinking water.

  5. Validated method for determination of eight banned nitroimidazole residues in natural casings by LC/MS/MS with solid-phase extraction.

    PubMed

    Sun, Hanwen; Wang, Fengchi; Ai, Lianfeng; Guo, Chunhai; Chen, Ruichun

    2009-01-01

    A sensitive method based on solid-phase extraction-liquid chromatography-tandem mass spectrometry interfaced with electrospray ionization (SPE-LC-MS/MS-ESI) was developed for the simultaneous determination of 8 banned nitroimidazole (NOZ) drugs including metronidazole (MNZ), ronidazole (RNZ), dimetridazole (DMZ), tinidazole, ornidazole, secnidazole, metronidazole-OH (MNZOH, the metabolite of MNZ), and 2-hydroxymethyl-1-methyl-5-nitroimidazole (HMMNI, the metabolite of RNZ and DMZ) in natural casings. After extraction with ethyl acetate and evaporation, the NOZs were reconstituted in ethyl acetate and purified on a strong cation-exchange SPE column, and then LC/MS/MS analysis was performed by positive ESI applying multiple reaction monitoring of 2 transition reactions for each compound. The method was validated according to the European Union requirements (Commission Decision 2002/657/EC). Specificity, linearity, decision limit (CCalpha), detection capability (CCbeta), accuracy, and precision were determined. Average recoveries of the 8 NOZs from natural animal casing fortified at 3 levels (0.1, 0.5, and 1 microg/kg) ranged from 87.3 to 116.5%. The calculated CCalpha for NOZs ranged from 0.029 to 0.049 microg/kg, and CCbeta ranged from 0.049 to 0.083 microg/kg. Repeatability was in the range of 3.35-10.1%, and within-laboratory reproducibility was <10.3%.

  6. LC-MS/MS method for simultaneous determination of thalidomide, lenalidomide, cyclophosphamide, bortezomib, dexamethasone and adriamycin in serum of multiple myeloma patients.

    PubMed

    Shu, Chang; Zeng, Tianmei; Gao, Shouhong; Xia, Tianyi; Huang, Lifeng; Zhang, Feng; Chen, Wansheng

    2016-08-15

    Multiple myeloma (MM), a malignant neoplastic serum-cell disorder, has been a serious threat to human health. The determination of 6 commonly used drug concentrations, including thalidomide, lenalidomide, cyclophosphamide, bortezomib, dexamethasone and adriamycin, in MM patients was of great clinical interest. Herein, we reported a method for the rapid and simultaneous measurement of the above therapeutics by liquid chromatography-tandem mass spectroscopy (LC-MS/MS) method with solid phase extraction. Analysis was performed on a Waters XBridge(®) BEH C18 column (2.5μm, 2.1 mm×50mm), with formic acid aqueous solution and acetonitrile as the mobile phase at flow rate 0.3mL/min. All analytes showed good correlation coefficients (r>0.996), and LLOQ of thalidomide, lenalidomide, cyclophosphamide, bortezomib, dexamethasone and adriamycin were 4, 2, 2, 2, 2 and 2ng/mL, respectively. The inter- and intra-day precisions and stability were expressed as variation coefficients within 15% and relative error less than 15%. Dilution effect, carryover and incurred sample reanalysis were investigated according to the 2015 edition Chinese Pharmacopoeia guidelines, as US FDA (2013, revision 1) required. The LC-MS/MS based assay described in this article may improve future clinical studies evaluating common therapeutics for MM treatment. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Determination of Acid Herbicides Using Modified QuEChERS with Fast Switching ESI(+)/ESI(-) LC-MS/MS.

    PubMed

    Sack, Chris; Vonderbrink, John; Smoker, Michael; Smith, Robert E

    2015-11-04

    A method for the determination of 35 acid herbicides in food matrices was developed, validated, and implemented. It utilizes a modified QuEChERS extraction procedure coupled with quantitation by liquid chromatography tandem mass spectrometry (LC-MS/MS). The acid herbicides analyzed are all organic carboxylic acids, including the older chlorophenoxy acid herbicides such as 2,4-dichlorophenoxyacetic acid (2,4-D), dicamba, 4-chlorophenoxyacetic acid (4-CPA), quinclorac, and many of the newer imidazolinone herbicides such as imazethapyr and imazaquin. In the procedure, 10 mL of water is added to 5 g of sample and then extracted with 1% formic acid in acetonitrile for 1 min. The acetonitrile phase is salted out of the extract by adding sodium chloride and magnesium sulfate, followed by centrifugation. The acetonitrile is diluted 1:1 with water to enable quantitation by LC-MS/MS using fast switching between positive and negative electrospray ionization modes. The average recoveries for all the compounds except aminocyclopyrachlor were 95% with a precision of 8%. The method detection limits for all residues were less than 10 ng/g, and the correlation coefficients for the calibration curves was greater than 0.99 for all but two compounds tested. The method was used successfully for the quantitation of acid herbicides in the FDA's total diet study. The procedure proved to be accurate, precise, linear, sensitive, and rugged.

  8. Application of Ultra-performance Liquid Chromatography with Time-of-Flight Mass Spectrometry for the Rapid Analysis of Constituents and Metabolites from the Extracts of Acanthopanax senticosus Harms Leaf

    PubMed Central

    Zhang, Yingzhi; Zhang, Aihua; Zhang, Ying; Sun, Hui; Meng, Xiangcai; Yan, Guangli; Wang, Xijun

    2016-01-01

    Acanthopanax senticosus (Rupr and Maxim) Harms (AS), a member of Araliaceae family, is a typical folk medicinal herb, which is widely distributed in the Northeastern part of China. Due to lack of this resource caused by the extensive use of its root, this work studied the chemical constituents of leaves of this plant with the purpose of looking for an alternative resource. In this work, a fast and optimized ultra-performance liquid chromatography method with quadrupole time-of-flight mass spectrometry (UPLC-QTOF-MS) has been developed for the analysis of constituents in leaves extracts. A total of 131 compounds were identified or tentatively characterized including triterpenoid saponins, phenols, flavonoids, lignans, coumarins, polysaccharides, and other compounds based on their fragmentation behaviors. Besides, a total of 21 metabolites were identified in serum in rats after oral administration, among which 12 prototypes and 9 metabolites through the metabolic pathways of reduction, methylation, sulfate conjugation, sulfoxide to thioether and deglycosylation. The coupling of UPLC-QTOF-MS led to the in-depth characterization of the leaves extracts of AS both in vitro and in vivo on the basis of retention time, mass accuracy, and tandem MS/MS spectra. It concluded that this analytical tool was very valuable in the study of complex compounds in medicinal herb. HIGHLIGHT OF PAPER A fast UPLC-QTOF-MS has been developed for analysis of constituents in leaves extractsA total of 131 compounds were identified in leaves extractsA total of 21 metabolites including 12 prototypes and 9 metabolites were identified in vivo. SUMMARY Constituent’s analysis of Acanthopanax senticosus Harms leaf by ultra-performance liquid chromatography method with quadrupole time-of-flight mass spectrometry. Abbreviations used: AS: Acanthopanax senticosus (Rupr and Maxim) Harms, TCHM: Traditional Chinese herbal medicine, UPLC-QTOF-MS: Ultra-performance liquid chromatography method with time-of-flight mass spectrometry, MS/MS: Tandem mass spectrometry, PCA: Principal component analysis, PLS-DA: Partial least squared discriminant analysis, OPLS-DA: Orthogonal projection to latent structure-discriminant analysis. PMID:27076752

  9. Current status of matrix-assisted laser desorption ionisation-time of flight mass spectrometry in the clinical microbiology laboratory.

    PubMed

    Kok, Jen; Chen, Sharon C A; Dwyer, Dominic E; Iredell, Jonathan R

    2013-01-01

    The integration of matrix-assisted laser desorption ionisation-time of flight mass spectrometry (MALDI-TOF MS) into many clinical microbiology laboratories has revolutionised routine pathogen identification. MALDI-TOF MS complements and has good potential to replace existing phenotypic identification methods. Results are available in a more clinically relevant timeframe, particularly in bacteraemic septic shock. Novel applications include strain typing and the detection of antimicrobial resistance, but these are not widely used. This review discusses the technical aspects, current applications, and limitations of MALDI-TOF MS.

  10. Characterization of physalins and fingerprint analysis for the quality evaluation of Physalis alkekengi L. var. franchetii by ultra-performance liquid chromatography combined with diode array detection and electrospray ionization tandem mass spectrometry.

    PubMed

    Zheng, Yunliang; Luan, Lianjun; Chen, Yong; Ren, Yiping; Wu, Yongjiang

    2012-12-01

    Physalins are important bioactive compounds from genus Physalis. They often occur as isomers, which makes the structural elucidation difficult. In the present study, the fragmentation behavior and UV characteristics of seven physalins from genus Physalis were firstly investigated using electrospray ionization tandem mass spectrometry (ESI-MS/MS) and diode array detection (DAD). Combined with ultra-performance liquid chromatography (UPLC) and DAD, the established approach to the structural identification of physalins by ESI-MS/MS was then applied to the analysis of Physalis alkekengi L. According to the UPLC retention behavior, the diagnostic UV spectra and the molecular structural information provided by MS/MS spectra, about 19 fingerprint peaks were identified, including 14 physalins and 5 other compounds. Finally, the established fingerprint method was applied to the analysis of 31 P. alkekengi L. samples collected from different locations, which reflected their similar chemical constituent properties. The proposed method provides a scientific and technical platform to the herbal industry for quality control and safety assurance of herbal preparations that contain this class of physalins. Copyright © 2012 Elsevier B.V. All rights reserved.

  11. Determination of Free and Total Choline and Carnitine in Infant Formula and Adult/Pediatric Nutritional Formula by Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS): Single-Laboratory Validation, First Action 2015.10.

    PubMed

    Ellingson, David J; Shippar, Jeffrey J; Gilmore, Justin M

    2016-01-01

    Analytical methods for the analysis of both L-carnitine and choline are needed for reliable and accurate determination in infant formula and adult/pediatric nutritional formula. These compounds are different in how they are utilized by the human body, but are structurally similar. L-carnitine and choline are quaternary ammonium compounds, enabling both to be retained under acidic conditions with strong cation exchange (SCX) chromatography. This method analyzes both compounds simultaneously as either the free forms or as a total amount that includes bound sources such as phosphatidylcholine or acetylcarnitine. The free analysis consists of water extraction and analysis by LC/MS/MS, while the total analysis consists of extraction by acid assisted microwave hydrolysis and analysis by LC/MS/MS. Calibration standards used for calculations are extracted with all samples in the batch. A single laboratory validation (SLV) was performed following the guidelines of the AOAC Stakeholder Panel on Infant Formula and Adult Nutritionals (SPIFAN) utilizing the kit of materials provided. The results achieved meet the requirements of SMPR 2012.010 and 2012.013 for L-carnitine and total choline, respectively.

  12. [Utility of MALDI-TOF MS for the identification of anaerobic bacteria].

    PubMed

    Zárate, Mariela S; Romano, Vanesa; Nievas, Jimena; Smayevsky, Jorgelina

    2014-01-01

    The analysis by MALDI-TOF MS (Matrix-assited laser desorption/ionization time-of-flight mass spectrometry) has become a reference method for the identification of microorganisms in Clinical Microbiology. However, data on some groups of microorganisms are still controversial. The aim of this study is to determine the utility of MALDI-TOF MS for the identification of clinical isolates of anaerobic bacteria. One-hundred and six anaerobic bacteria isolates were analyzed by MALDI-TOF MS and by conventional biochemical tests. In those cases where identification by conventional methodology was not applicable or in the face of discordance between sequencing methodologies, 16 S rRNA gene sequence analysis was performed. The conventional method and MALDI-TOF MS agreed at genus and species level by 95.3 %. Concordance in gram-negative bacilli was 91.4% and 100% among gram-positive bacilli; there was also concordance both in the 8 isolates studied in gram-positive cocci and in the single gram-negative cocci included. The data obtained in this study demonstrate that MALDI-TOF MS offers the possibility of adequate identification of anaerobic bacteria. Copyright © 2014 Asociación Colombiana de Psiquiatría. Publicado por Elsevier España. All rights reserved.

  13. Simultaneous quantitation of delamanid (OPC-67683) and its eight metabolites in human plasma using UHPLC-MS/MS.

    PubMed

    Meng, Min; Smith, Benjamin; Johnston, Brad; Carter, Spencer; Brisson, Jerry; Roth, Sharin E

    2015-10-01

    Delamanid (OPC-67683) is a novel nitro-dihydroimidazo-oxazole derivative that is being developed by Otsuka Pharmaceutical Co., Ltd., Japan (referred to as Otsuka hereafter) for the treatment of tuberculosis (TB). An ultra-high performance liquid chromatographic-tandem mass spectrometry (UHPLC-MS/MS) method has been developed and validated for the determination of OPC-67683 and its eight metabolites, DM-6704, DM-6705, DM-6706, DM-6717, DM-6718, DM-6720, DM-6721 and DM-6722 in human plasma to support regulated clinical development. During method development several technical challenges such as poor chromatography, separation of structural isomers, conversion of the analytes, instability in matrix and long cycle time were encountered and overcome. A protein precipitation extraction (PPE) was used to extract plasma samples (50μL) and the resulting extracts were analyzed using reversed phase UHPLC-MS/MS with a electrospray (ESI) and selected reaction monitoring (SRM). The method was fully validated over the calibration curve range of 1.00-500ng/mL for all nine analytes with linear regression and 1/x(2) weighting according to regulatory guidance for bioanalysis. Based on three inter-day precision and accuracy runs, the between-run % relative standard deviation (RSD) for all nine analytes varied from 0.0 to 11.9% and the accuracy ranged from 92.7% to 102.5% of nominal at all quality controls (QC) concentrations, including the lower limit of quantitation (LLOQ) QC at 1.00ng/mL. The extraction recovery of OPC-67683 and its eight metabolites were above 95%. Various short term and long term solution and matrix stability were established including the stability of OPC-67683 and its eight metabolites in human plasma for 708 days at -70°C. Although this method has been used to support regulated clinic studies during the last decade and over ten thousand samples have been analyzed, this is the first time that the method development process and validation data have been published. Copyright © 2015 Elsevier B.V. All rights reserved.

  14. Data-Independent Mass Spectrometry Approach for Screening and Identification of DNA Adducts.

    PubMed

    Guo, Jingshu; Villalta, Peter W; Turesky, Robert J

    2017-11-07

    Long-term exposures to environmental toxicants and endogenous electrophiles are causative factors for human diseases including cancer. DNA adducts reflect the internal exposure to genotoxicants and can serve as biomarkers for risk assessment. Liquid chromatography-multistage mass spectrometry (LC-MS n ) is the most common method for biomonitoring DNA adducts, generally targeting single exposures and measuring up to several adducts. However, the data often provide limited evidence for a role of a chemical in the etiology of cancer. An "untargeted" method is required that captures global exposures to chemicals, by simultaneously detecting their DNA adducts in the genome; some of which may induce cancer-causing mutations. We established a wide selected ion monitoring tandem mass spectrometry (wide-SIM/MS 2 ) screening method utilizing ultraperformance-LC nanoelectrospray ionization Orbitrap MS n with online trapping to enrich bulky, nonpolar adducts. Wide-SIM scan events are followed by MS 2 scans to screen for modified nucleosides by coeluting peaks containing precursor and fragment ions differing by -116.0473 Da, attributed to the neutral loss of deoxyribose. Wide-SIM/MS 2 was shown to be superior in sensitivity, specificity, and breadth of adduct coverage to other tested adductomic methods with detection possible at adduct levels as low as 4 per 10 9 nucleotides. Wide-SIM/MS 2 data can be analyzed in a "targeted" fashion by generation of extracted ion chromatograms or in an "untargeted" fashion where a chromatographic peak-picking algorithm can be used to detect putative DNA adducts. Wide-SIM/MS 2 successfully detected DNA adducts, derived from chemicals in the diet and traditional medicines and from lipid peroxidation products, in human prostate and renal specimens.

  15. Overlapping MALDI-Mass Spectrometry Imaging for In-Parallel MS and MS/MS Data Acquisition without Sacrificing Spatial Resolution

    NASA Astrophysics Data System (ADS)

    Hansen, Rebecca L.; Lee, Young Jin

    2017-09-01

    Metabolomics experiments require chemical identifications, often through MS/MS analysis. In mass spectrometry imaging (MSI), this necessitates running several serial tissue sections or using a multiplex data acquisition method. We have previously developed a multiplex MSI method to obtain MS and MS/MS data in a single experiment to acquire more chemical information in less data acquisition time. In this method, each raster step is composed of several spiral steps and each spiral step is used for a separate scan event (e.g., MS or MS/MS). One main limitation of this method is the loss of spatial resolution as the number of spiral steps increases, limiting its applicability for high-spatial resolution MSI. In this work, we demonstrate multiplex MS imaging is possible without sacrificing spatial resolution by the use of overlapping spiral steps, instead of spatially separated spiral steps as used in the previous work. Significant amounts of matrix and analytes are still left after multiple spectral acquisitions, especially with nanoparticle matrices, so that high quality MS and MS/MS data can be obtained on virtually the same tissue spot. This method was then applied to visualize metabolites and acquire their MS/MS spectra in maize leaf cross-sections at 10 μm spatial resolution. [Figure not available: see fulltext.

  16. Characterization and quantitation of yohimbine and its analogs in botanicals and dietary supplements using LC/QTOF-MS and LC/QQQ-MS for determination of the presence of bark extract and yohimbine adulteration.

    PubMed

    Lucas, Derick; Neal-Kababick, James; Zweigenbaum, Jerry

    2015-01-01

    The compound yohimbine HCl has been restricted in Australia and categorized as a scheduled prescription drug in other parts of the world, including the United States where it is monographed as a drug in the U. S. Pharmacopeia. However, the bark of the yohimbe plant and its extract is considered a botanical that can be used as a dietary supplement in some parts of the world. For these reasons, methods to characterize the indole alkaloids of the bark and quantify yohimbine and its analogs are presented using accurate mass LC/quadrupole time-of-flight (QTOF)-MS and triple quadrupole LC/MS, respectively. Samples were extracted with a QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Safe) method to characterize and quantify the indole alkaloids. With the LC/QTOF-MS in auto MS/MS mode the indole alkaloids were identified, and the isomeric response of each could be used to determine whether the actual bark or extract was in samples of dietary supplements and not adulteration with yohimbine HCl. Analogs were identified and include yohimbic acid, methyl yohimbine, and hydroxyl yohimbine. Many isomers of each were also detected, but identified only by the number of chromatographic peaks. Quantification of yohimbine and ajmalicine spiked extracts showed recoveries of 99 to 103% with RSD of 3.6% or lower and LODs of less than 100 ppt. Calibration of the two standards gave r(2) = 0.9999 in a range from 0.1 to 100 ppb. Dietary supplements quantified for these two compounds showed a range from not detected to 3x the amounts found in the bark.

  17. Measurement of phospholipids by hydrophilic interaction liquid chromatography coupled to tandem mass spectrometry: the determination of choline containing compounds in foods.

    PubMed

    Zhao, Yuan-Yuan; Xiong, Yeping; Curtis, Jonathan M

    2011-08-12

    A hydrophilic interaction liquid chromatography-tandem mass spectrometry (HILIC LC-MS/MS) method using multiple scan modes was developed to separate and quantify 11 compounds and lipid classes including acetylcholine (AcCho), betaine (Bet), choline (Cho), glycerophosphocholine (GPC), lysophosphatidylcholine (LPC), lysophosphatidylethanolamine (LPE), phosphatidylcholine (PC), phosphatidylethanolamine (PE), phosphatidylinositol (PI), phosphocholine (PCho) and sphingomyelin (SM). This includes all of the major choline-containing compounds found in foods. The method offers advantages over other LC methods since HILIC chromatography is readily compatible with electrospray ionization and results in higher sensitivity and improved peak shapes. The LC-MS/MS method allows quantification of all choline-containing compounds in a single run. Tests of method suitability indicated linear ranges of approximately 0.25-25 μg/ml for PI and PE, 0.5-50 μg/ml for PC, 0.05-5 μg/ml for SM and LPC, 0.5-25 μg/ml for LPE, 0.02-5 μg/ml for Cho, and 0.08-8 μg/ml for Bet, respectively. Accuracies of 83-105% with precisions of 1.6-13.2% RSD were achieved for standards over a wide range of concentrations, demonstrating that this method will be suitable for food analysis. 8 polar lipid classes were found in a lipid extract of egg yolk and different species of the same class were differentiated based on their molecular weights and fragment ion information. PC and PE were found to be the most abundant lipid classes consisting of 71% and 18% of the total phospholipids in egg yolk. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. Multiple sclerosis - etiology and diagnostic potential.

    PubMed

    Kamińska, Joanna; Koper, Olga M; Piechal, Kinga; Kemona, Halina

    2017-06-30

    Multiple sclerosis (MS) is a chronic inflammatory and demyelinating disease of autoimmune originate. The main agents responsible for the MS development include exogenous, environmental, and genetic factors. MS is characterized by multifocal and temporally scattered central nervous system (CNS) damage which lead to the axonal damage. Among clinical courses of MS it can be distinguish relapsing-remitting multiple sclerosis (RRMS), secondary progressive multiple sclerosis (SPSM), primary progressive multiple sclerosis (PPMS), and progressive-relapsing multiple sclerosis (RPMS). Depending on the severity of signs and symptoms MS can be described as benign MS or malignant MS. MS diagnosis is based on McDonald's diagnostic criteria, which link clinical manifestation with characteristic lesions demonstrated by magnetic resonance imaging (MRI), cerebrospinal fluid (CSF) analysis, and visual evoked potentials. Among CSF laboratory tests used to the MS diagnosis are applied: Tibbling & Link IgG index, reinbegrams, and CSF isoelectrofocusing for oligoclonal bands detection. It should be emphasized, that despite huge progress regarding MS as well as the availability of different diagnostics methods this disease is still a diagnostic challenge. It may result from fact that MS has diverse clinical course and there is a lack of single test, which would be of appropriate diagnostic sensitivity and specificity for quick and accurate diagnosis.

  19. Effect of acupressure on fatigue in women with multiple sclerosis.

    PubMed

    Bastani, Farideh; Sobhani, Marzie; Emamzadeh Ghasemi, Hormat Sadat

    2015-01-26

    Multiple sclerosis (MS) is the most common cause of progressive neurological disability. The prevalence of MS is much more common in women than men. The women are exposed to a variety of symptoms including fatigue. Acupressure is a noninvasive procedure that can be used to control symptoms including fatigue. The aim of the study was to evaluate the effect of acupressure on fatigue in women with multiple sclerosis. A randomized clinical trial was conducted on 100 women with MS at Tehran MS Association. The subjects were equally allocated to experimental group and a placebo group (50 women per group) by blocking randomization method. The experimental group were received acupressure, at the true points (ST36, SP6, LI4) and the placebo group, were received touching at the same points. Fatigue was measured by a Fatigue Severity Scale (FSS) in the groups at immediately prior to, two and four weeks after the beginning of the intervention. The data was analyzed using descriptive and inferential statistics by SPSS version 17. The findings indicated no differences in demographic characteristics and the severity of fatigue at the baseline in two groups (p=0.54). But there were significant reductions of the mean score of fatigue in the experimental group compared to the placebo group immediately, two and four weeks after the intervention respectively (p=0.03, p?0/001, p=0.04). According to the findings, the study provided an alternative method for health care providers including nurses to train acupressure to the clients with MS to managing their fatigue.

  20. Impact of glucuronide interferences on therapeutic drug monitoring of posaconazole by tandem mass spectrometry.

    PubMed

    Krüger, Ralf; Vogeser, Michael; Burghardt, Stephan; Vogelsberger, Rita; Lackner, Karl J

    2010-12-01

    Posaconazole is a novel antifungal drug for oral application intended especially for therapy of invasive mycoses. Due to variable gastrointestinal absorption, adverse side effects, and suspected drug-drug interactions, therapeutic drug monitoring (TDM) of posaconazole is recommended. A fast ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for quantification of posaconazole with a run-time <3 min was developed and compared to a LC-MS/MS method and HPLC method with fluorescence detection. During evaluation of UPLC-MS/MS, two earlier eluting peaks were observed in the MRM trace of posaconazole. This was only seen in patient samples, but not in spiked calibrator samples. Comparison with LC-MS/MS disclosed a significant bias with higher concentrations measured by LC-MS/MS, while UPLC-MS/MS showed excellent agreement with the commercially available HPLC method. In the LC-MS/MS procedure, comparably wide and left side shifted peaks were noticed. This could be ascribed to in-source fragmentation of conjugate metabolites during electrospray ionisation. Precursor and product ion scans confirmed the assumption that the additional compounds are posaconazole glucuronides. Reducing the cone voltage led to disappearance of the glucuronide peaks. Slight modification of the LC-MS/MS method enabled separation of the main interference, leading to significantly reduced deviation. These results highlight the necessity to reliably eliminate interference from labile drug metabolites for correct TDM results, either by sufficient separation or selective MS conditions. The presented UPLC-MS/MS method provides a reliable and fast assay for TDM of posaconazole.

  1. Rapid analysis of the main components of the total glycosides of Ranunculus japonicus by UPLC/Q-TOF-MS.

    PubMed

    Rui, Wen; Chen, Hongyuan; Tan, Yuzhi; Zhong, Yanmei; Feng, Yifan

    2010-05-01

    A rapid method for the analysis of the main components of the total glycosides of Ranunculus japonicus (TGOR) was developed using ultra-performance liquid chromatography with quadrupole-time-of-flight mass spectrometry (UPLC/Q-TOF-MS). The separation analysis was performed on a Waters Acquity UPLC system and the accurate mass of molecules and their fragment ions were determined by Q-TOF MS. Twenty compounds, including lactone glycosides, flavonoid glycosides and flavonoid aglycones, were identified and tentatively deduced on the basis of their elemental compositions, MS/MS data and relevant literature. The results demonstrated that lactone glycosides and flavonoids were the main constituents of TGOR. Furthermore, an effective and rapid pattern was established allowing for the comprehensive and systematic characterization of the complex samples.

  2. Comprehensive Profiling and Quantification of Ginsenosides in the Root, Stem, Leaf, and Berry of Panax ginseng by UPLC-QTOF/MS.

    PubMed

    Lee, Jae Won; Choi, Bo-Ram; Kim, Young-Chang; Choi, Doo Jin; Lee, Young-Seob; Kim, Geum-Soog; Baek, Nam-In; Kim, Seung-Yu; Lee, Dae Young

    2017-12-04

    The effective production and usage of ginsenosides, given their distinct pharmacological effects, are receiving increasing amounts of attention. As the ginsenosides content differs in different parts of Panax ginseng, we wanted to assess and compare the ginsenosides content in the ginseng roots, leave, stems, and berries. To extract the ginsenosides, 70% (v/v) methanol was used. The optimal ultra-performance liquid chromatography-quadrupole time of flight mass spectrometry (UPLC-QTOF/MS) method was used to profile various ginsenosides from the different parts of P. ginseng. The datasets were then subjected to multivariate analysis including principal component analysis (PCA) and hierarchical clustering analysis (HCA). A UPLC-QTOF/MS method with an in-house library was constructed to profile 58 ginsenosides. With this method, a total of 39 ginsenosides were successfully identified and quantified in the ginseng roots, leave, stem, and berries. PCA and HCA characterized the different ginsenosides compositions from the different parts. The quantitative ginsenoside contents were also characterized from each plant part. The results of this study indicate that the UPLC-QTOF/MS method can be an effective tool to characterize various ginsenosides from the different parts of P. ginseng.

  3. Natural chlorate in the environment: Application of a new IC-ESI/MS/MS method with a Cl18O3- internal standard

    USGS Publications Warehouse

    Rao, Balaji; Hatzinger, Paul B.; Böhlke, John Karl; Sturchio, Neil C.; Andraski, Brian J.; Eckardt, Frank D.; Jackson, W. Andrew

    2010-01-01

    A new ion chromatography electrospray tandem mass spectrometry (IC-ESI/MS/MS) method has been developed for quantification and confirmation of chlorate (ClO3−) in environmental samples. The method involves the electro-chemical generation of isotopically labeled chlorate internal standard (Cl18O3−) using 18O water (H218O). The standard was added to all samples prior to analysis thereby minimizing the matrix effects that are associated with common ions without the need for expensive sample pretreatments. The method detection limit (MDL) for ClO3− was 2 ng L−1 for a 1 mL volume sample injection. The proposed method was successfully applied to analyze ClO3− in difficult environmental samples including soil and plant leachates. The IC-ESI/MS/MS method described here was also compared to established EPA method 317.0 for ClO3− analysis. Samples collected from a variety of environments previously shown to contain natural perchlorate (ClO4−) occurrence were analyzed using the proposed method and ClO3− was found to co-occur with ClO4− at concentrations ranging from <2 ng L−1 in precipitation from Texas and Puerto Rico to >500 mg kg−1 in caliche salt deposits from the Atacama Desert in Chile. Relatively low concentrations of ClO3− in some natural groundwater samples (<0.1 μg L−1) analyzed in this work may indicate lower stability when compared to ClO4− in the subsurface. The high concentrations of ClO3− in caliches and soils (3−6 orders of magnitude greater) as compared to precipitation samples indicate that ClO3−, like ClO4−, may be atmospherically produced and deposited, then concentrated in dry soils, and is possibly a minor component in the biogeochemical cycle of chlorine.

  4. Natural chlorate in the environment: application of a new IC-ESI/MS/MS method with a Cl¹⁸O₃-internal standard.

    PubMed

    Balaji Rao, Balaji Rao; Hatzinger, Paul B; Böhlke, John Karl; Sturchio, Neil C; Andraski, Brian J; Eckardt, Frank D; Jackson, W Andrew

    2010-11-15

    A new ion chromatography electrospray tandem mass spectrometry (IC-ESI/MS/MS) method has been developed for quantification and confirmation of chlorate (ClO₃⁻) in environmental samples. The method involves the electrochemical generation of isotopically labeled chlorate internal standard (Cl¹⁸O₃⁻) using ¹⁸O water (H₂¹⁸O) he standard was added to all samples prior to analysis thereby minimizing the matrix effects that are associated with common ions without the need for expensive sample pretreatments. The method detection limit (MDL) for ClO₃⁻ was 2 ng L⁻¹ for a 1 mL volume sample injection. The proposed method was successfully applied to analyze ClO₃⁻ in difficult environmental samples including soil and plant leachates. The IC-ESI/MS/MS method described here was also compared to established EPA method 317.0 for ClO₃⁻ analysis. Samples collected from a variety of environments previously shown to contain natural perchlorate (ClO₄⁻) occurrence were analyzed using the proposed method and ClO₃⁻ was found to co-occur with ClO₄⁻ at concentrations ranging from < 2 ng L⁻¹ in precipitation from Texas and Puerto Rico to >500 mg kg⁻¹ in caliche salt deposits from the Atacama Desert in Chile. Relatively low concentrations of ClO₃⁻ in some natural groundwater samples (0.1 µg L⁻¹) analyzed in this work may indicate lower stability when compared to ClO₄⁻ in the subsurface. The high concentrations ClO₃⁻ in caliches and soils (3-6 orders of magnitude greater) as compared to precipitation samples indicate that ClO₃⁻, like ClO₄⁻, may be atmospherically produced and deposited, then concentrated in dry soils, and is possibly a minor component in the biogeochemical cycle of chlorine.

  5. A comparison between DART-MS and DSA-MS in the forensic analysis of writing inks.

    PubMed

    Drury, Nicholas; Ramotowski, Robert; Moini, Mehdi

    2018-05-23

    Ambient ionization mass spectrometry is gaining momentum in forensic science laboratories because of its high speed of analysis, minimal sample preparation, and information-rich results. One such application of ambient ionization methodology includes the analysis of writing inks from questioned documents where colorants of interest may not be soluble in common solvents, rendering thin layer chromatography (TLC) and separation-mass spectrometry methods such as LC/MS (-MS) impractical. Ambient ionization mass spectrometry uses a variety of ionization techniques such as penning ionization in Direct Analysis in Real Time (DART), and atmospheric pressure chemical ionization in Direct Sample Analysis (DSA), and electrospray ionization in Desorption Electrospray Ionization (DESI). In this manuscript, two of the commonly used ambient ionization techniques are compared: Perkin Elmer DSA-MS and IonSense DART in conjunction with a JEOL AccuTOF MS. Both technologies were equally successful in analyzing writing inks and produced similar spectra. DSA-MS produced less background signal likely because of its closed source configuration; however, the open source configuration of DART-MS provided more flexibility for sample positioning for optimum sensitivity and thereby allowing smaller piece of paper containing writing ink to be analyzed. Under these conditions, the minimum sample required for DART-MS was 1mm strokes of ink on paper, whereas DSA-MS required a minimum of 3mm. Moreover, both techniques showed comparable repeatability. Evaluation of the analytical figures of merit, including sensitivity, linear dynamic range, and repeatability, for DSA-MS and DART-MS analysis is provided. To the forensic context of the technique, DART-MS was applied to the analysis of United States Secret Service ink samples directly on a sampling mesh, and the results were compared with DSA-MS of the same inks on paper. Unlike analysis using separation mass spectrometry, which requires sample preparation, both DART-MS and DSA-MS successfully analyzed writing inks with minimal sample preparation. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Advanced hyphenated chromatographic-mass spectrometry in mycotoxin determination: current status and prospects.

    PubMed

    Li, Peiwu; Zhang, Zhaowei; Hu, Xiaofeng; Zhang, Qi

    2013-01-01

    Mass spectrometric techniques are essential for advanced research in food safety and environmental monitoring. These fields are important for securing the health of humans and animals, and for ensuring environmental security. Mycotoxins, toxic secondary metabolites of filamentous fungi, are major contaminants of agricultural products, food and feed, biological samples, and the environment as a whole. Mycotoxins can cause cancers, nephritic and hepatic diseases, various hemorrhagic syndromes, and immune and neurological disorders. Mycotoxin-contaminated food and feed can provoke trade conflicts, resulting in massive economic losses. Risk assessment of mycotoxin contamination for humans and animals generally depends on clear identification and reliable quantitation in diversified matrices. Pioneering work on mycotoxin quantitation using mass spectrometry (MS) was performed in the early 1970s. Now, unambiguous confirmation and quantitation of mycotoxins can be readily achieved with a variety hyphenated techniques that combine chromatographic separation with MS, including liquid chromatography (LC) or gas chromatography (GC). With the advent of atmospheric pressure ionization, LC-MS has become a routine technique. Recently, the co-occurrence of multiple mycotoxins in the same sample has drawn an increasing amount of attention. Thus, modern analyses must be able to detect and quantitate multiple mycotoxins in a single run. Improvements in tandem MS techniques have been made to achieve this purpose. This review describes the advanced research that has been done regarding mycotoxin determination using hyphenated chromatographic-MS techniques, but is not a full-circle survey of all the literature published on this topic. The present work provides an overview of the various hyphenated chromatographic-MS-based strategies that have been applied to mycotoxin analysis, with a focus on recent developments. The use of chromatographic-MS to measure levels of mycotoxins, including aflatoxins, ochratoxins, patulin, trichothecenes, zearalenone, and fumonisins, is discussed in detail. Both free and masked mycotoxins are included in this review due to different methods of sample preparation. Techniques are described in terms of sample preparation, internal standards, LC/ultra performance LC (UPLC) optimization, and applications and survey. Several future hyphenated MS techniques are discussed as well, including multidimensional chromatography-MS, capillary electrophoresis-MS, and surface plasmon resonance array-MS. © 2013 Wiley Periodicals, Inc.

  7. Therapeutic Yoga: Symptom Management for Multiple Sclerosis

    PubMed Central

    MacDonald, Megan

    2015-01-01

    Abstract Multiple sclerosis (MS) is the most common autoimmune inflammatory demyelinating disease of the central nervous system, affecting over 2.3 million people worldwide. According to the National Institute of Neurological Disorders and Stroke, the age of disease onset is typically between 20 and 40 years, with a higher incidence in women. Individuals with MS experience a wide range of symptoms, including declining physical, emotional, and psychological symptoms (e.g., fatigue, imbalance, spasticity, chronic pain, cognitive impairment, bladder and bowel dysfunction, visual and speech impairments, depression, sensory disturbance, and mobility impairment). To date, both the cause of and cure for MS remain unknown. In recent years, more individuals with MS have been pursuing alternative methods of treatment to manage symptoms of the disease, including mind-body therapies such as yoga, meditation, breathing, and relaxation techniques. It has been suggested that the practice of yoga may be a safe and effective way of managing symptoms of MS. Therefore, the purpose of this paper is to summarize the most relevant literature on exercise and mind-body modalities to treat MS symptoms and, more specifically, the benefits and potential role of yoga as an alternative treatment of symptom management for individuals with MS. The article also discusses future directions for research. PMID:26270955

  8. Ellagitannin composition of blackberry as determined by HPLC-ESI-MS and MALDI-TOF-MS.

    PubMed

    Hager, Tiffany J; Howard, Luke R; Liyanage, Rohana; Lay, Jackson O; Prior, Ronald L

    2008-02-13

    Blackberries ( Rubus sp.) were evaluated by high-performance liquid chromatography-electrospray ionization-mass spectrometry (HPLC-ESI-MS) and matrix-assisted laser desorption/ionization-time-of-flight mass spectrometry (MALDI-TOF-MS) to identify the ellagitannins present in flesh, torus (receptacle tissue), and seeds. Most ellagitannins were present (or detectable) only in seed tissues. Ellagitannins identified by HPLC-ESI-MS in the seeds included pedunculagin, casuarictin/potentillin, castalagin/vescalagin, lambertianin A/sanguiin H-6, lambertianin C, and lambertianin D. For several of the ellagitannins, isomeric separation was also obtained. The MALDI-TOF-MS analysis was primarily utilized to evaluate and identify high molecular mass (>1000 Da) ellagitannins. The MALDI analysis verified the presence of the ellagitannins identified by HPLC-ESI-MS including lambertianin A/sanguiin H-6, lambertianin C, and lambertianin D, but the analysis also indicated the presence of several other compounds that were most likely ellagitannins based on the patterns observed in the masses (i.e., loss or addition of a gallic acid moiety to a known ellagitannin). This study determined the presence of several possible isomeric forms of ellagitannins previously unidentified in fruit and presents a possible analytical HPLC method for the analysis of the major ellagitannins present in the fruit.

  9. LC-MS/MS method for the determination of haemanthamine in rat plasma, bile and urine and its application to a pilot pharmacokinetic study.

    PubMed

    Hroch, Miloš; Mičuda, Stanislav; Havelek, Radim; Cermanová, Jolana; Cahlíková, Lucie; Hošťálková, Anna; Hulcová, Daniela; Řezáčová, Martina

    2016-07-01

    Evidence gathered in various studies points to the fact that haemanthamine, an isoquinoline alkaloid, has multiple medicinally interesting characteristics, including antitumor, antileukemic, antioxidant, antiviral, anticonvulsant and antimalarial activity. This work presents, for the first time, a universal LC-MS/MS method for analysis of haemanthamine in plasma, bile and urine which has been verified in a pilot pharmacokinetic experiment on rats. Chromatographic separation was performed on a pentafluorophenyl core-shell column in gradient elution mode with a mobile phase consisting of acetonitrile-methanol-ammonium formate buffer. A sample preparation based on liquid-liquid extraction with methyl tert-butyl ether was employed with ambelline used as an internal standard. Quantification was performed using LC-MS-ESI(+) in Selected Reaction Monitoring mode. The method was validated according to the European Medicines Agency guideline in a concentration range of 0.1-10 μmol/L in plasma, bile and urine. The concentration-time profiles of haemanthamine in plasma, bile and urine after a single i.v. bolus of 10 mg/kg have been described for the first time. The presented study addresses the lack of information on haemanthamine pharmacokinetics and also introduces a new universal method of haemanthamine analysis in complex biological matrices. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  10. Analysis of volatile compounds by open-air ionization mass spectrometry.

    PubMed

    Meher, Anil Kumar; Chen, Yu-Chie

    2017-05-08

    This study demonstrates a simple method for rapid and in situ identification of volatile and endogenous compounds in culinary spice samples through mass spectrometry (MS). This method only requires a holder for solid spice sample (2-3 mm) that is placed close to a mass spectrometer inlet, which is applied with a high voltage. Volatile species responsible for the aroma of the spice samples can be readily detected by the mass spectrometer. Sample pretreatment is not required prior to MS analysis, and no solvent was used during MS analysis. The high voltage applied to the inlet of the mass spectrometer induces the ionization of volatile compounds released from the solid spice samples. Furthermore, moisture in the air also contributes to the ionization of volatile compounds. Dried spices including cinnamon and cloves are used as the model sample to demonstrate this straightforward MS analysis, which can be completed within few seconds. Furthermore, we also demonstrate the suitability of the current method for rapid screening of cinnamon quality through detection of the presence of a hepatotoxic agent, i.e. coumarin. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Application of Fourier-transform ion cyclotron resonance mass spectrometry to metabolic profiling and metabolite identification.

    PubMed

    Ohta, Daisaku; Kanaya, Shigehiko; Suzuki, Hideyuki

    2010-02-01

    Metabolomics, as an essential part of genomics studies, intends holistic understanding of metabolic networks through simultaneous analysis of a myriad of both known and unknown metabolites occurring in living organisms. The initial stage of metabolomics was designed for the reproducible analyses of known metabolites based on their comparison to available authentic compounds. Such metabolomics platforms were mostly based on mass spectrometry (MS) technologies enabled by a combination of different ionization methods together with a variety of separation steps including LC, GC, and CE. Among these, Fourier-transform ion cyclotron resonance MS (FT-ICR/MS) is distinguished from other MS technologies by its ultrahigh resolution power in mass to charge ratio (m/z). The potential of FT-ICR/MS as a distinctive metabolomics tool has been demonstrated in nontargeted metabolic profiling and functional characterization of novel genes. Here, we discuss both the advantages and difficulties encountered in the FT-ICR/MS metabolomics studies.

  12. Evaluating Barriers to Adherence to Dietary Recommendations in Iranian Adults with Metabolic Syndrome: A Qualitative Study Using the Theory of Reasoned Action.

    PubMed

    Esmaeili, Naseh; Alizadeh, Mohammad; Tarighat Esfanjani, Ali; Kheirouri, Sorayya

    2016-07-01

    Metabolic syndrome (MS) is defined as a pattern of metabolic disorders including central obesity, insulin resistance or hyperglycemia, high blood pressure, and dyslipidemia. Many studies show a clear relationship between diet and components of MS. The aim of the current study was to identify barriers to adherence to dietary recommendations among Iranian MS patients. The theory of reasoned action (TRA) served as the framework for this qualitative study. Data collection was conducted through six semi-structured focus group discussions, from Apr to Jun 2013. Subjects included 36 married men and women with different levels of education between the ages of 20-50 with MS diagnosed based on IDF's (International Diabetes federation) criteria. All focus group discussions were audio recorded and transcribed. The thematic content analysis method was used to analyze the study data. This study identified the most important barriers to adherence to dietary recommendations. MS patients have problems in their attitude toward MS components and their relationship to nutrition. They also had wrong attitudes toward fats and oils, salt, dairy products, cereals, and sugary drinks and sweets. Subjective norms that affects patient eating identifies too. We identified barriers to adherence to dietary recommendations in MS patients that could be used to prevent MS consequences and provide patients with nutrition education.

  13. Difference gel electrophoresis (DiGE) identifies differentially expressed proteins in endoscopically-collected pancreatic fluid

    PubMed Central

    Paulo, Joao A.; Lee, Linda S.; Banks, Peter A.; Steen, Hanno; Conwell, Darwin L.

    2012-01-01

    Alterations in the pancreatic fluid proteome of individuals with chronic pancreatitis may offer insights into the development and progression of the disease. The endoscopic pancreas function test (ePFT) can safely collect large volumes of pancreatic fluid that are potentially amenable to proteomic analyses using difference gel electrophoresis (DiGE) coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS). Pancreatic fluid was collected endoscopically using the ePFT method following secretin stimulation from three individuals with severe chronic pancreatitis and three chronic abdominal pain controls. The fluid was processed to minimize protein degradation and the protein profiles of each cohort, as determined by DiGE and LC-MS/MS, were compared. This DiGE-LC-MS/MS analysis reveals proteins that are differentially expressed in chronic pancreatitis compared to chronic abdominal pain controls. Proteins with higher abundance in pancreatic fluid from chronic pancreatitis individuals include: actin, desmoplankin, alpha-1-antitrypsin, SNC73, and serotransferrin. Those of relatively lower abundance include carboxypeptidase B, lipase, alpha-1-antichymotrypsin, alpha-2-macroglobulin, Arp2/3 subunit 4, glyceraldehyde-3-phosphate dehydrogenase, and protein disulfide isomerase. Endoscopic collection (ePFT) in tandem with DiGE-LC-MS/MS is a suitable approach for pancreatic fluid proteome analysis, however, further optimization of our protocol, as outlined herein, may improve proteome coverage in future analyses. PMID:21792986

  14. Chemical fingerprint and metabolic profile analysis of Citrus reticulate 'Chachi' decoction by HPLC-PDA-IT-MS(n) and HPLC-Quadrupole-Orbitrap-MS method.

    PubMed

    Ye, Xiaolan; Cao, Di; Zhao, Xin; Song, Fenyun; Huang, Qinghua; Fan, Guorong; Wu, Fuhai

    2014-11-01

    A method incorporating HPLC-PDA-IT-MS(n) with HPLC-Quadrupole-Orbitrap-MS was developed for the investigation of chemical fingerprint of Citrus reticulate 'Chachi' decoction (CRCD) and metabolic profile of SD rat plasma sample after oral administration of CRCD (1.5 g herb/kg). A total of 27 chemical constituents of CRCD were identified from their MW, UV spectra, MS(n) data and retention behavior by comparing the results with those of the reference standards or literature. And 43 compounds were detected in dosed SD rat plasma samples, including 9 prototypes which were identified as hesperetin, isosinensetin, sinensetin, tetramethyl-O-isoscutellarein, nobiletin, tetramethyl-O-scutellarein, HMF (3,5,6,7,8,3',4'-heptamethoxyflavone), tangeretin and 5-demethylnobiletin and 34 metabolites underwent metabolic process of demethylation, glucuronide conjugation, sulfate conjugation or mixed modes. This is the first research for the metabolic profile of CRCD in SD rats, which could lay a foundation for the further studies of CRC or its formulation. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. A method for addressing differences in concentrations of fipronil and three degradates obtained by two different laboratory methods

    USGS Publications Warehouse

    Crawford, Charles G.; Martin, Jeffrey D.

    2017-07-21

    In October 2012, the U.S. Geological Survey (USGS) began measuring the concentration of the pesticide fipronil and three of its degradates (desulfinylfipronil, fipronil sulfide, and fipronil sulfone) by a new laboratory method using direct aqueous-injection liquid chromatography tandem mass spectrometry (DAI LC–MS/MS). This method replaced the previous method—in use since 2002—that used gas chromatography/mass spectrometry (GC/MS). The performance of the two methods is not comparable for fipronil and the three degradates. Concentrations of these four chemical compounds determined by the DAI LC–MS/MS method are substantially lower than the GC/MS method. A method was developed to correct for the difference in concentrations obtained by the two laboratory methods based on a methods comparison field study done in 2012. Environmental and field matrix spike samples to be analyzed by both methods from 48 stream sites from across the United States were sampled approximately three times each for this study. These data were used to develop a relation between the two laboratory methods for each compound using regression analysis. The relations were used to calibrate data obtained by the older method to the new method in order to remove any biases attributable to differences in the methods. The coefficients of the equations obtained from the regressions were used to calibrate over 16,600 observations of fipronil, as well as the three degradates determined by the GC/MS method retrieved from the USGS National Water Information System. The calibrated values were then compared to over 7,800 observations of fipronil and to the three degradates determined by the DAI LC–MS/MS method also retrieved from the National Water Information System. The original and calibrated values from the GC/MS method, along with measures of uncertainty in the calibrated values and the original values from the DAI LC–MS/MS method, are provided in an accompanying data release.

  16. Obesity during childhood and adolescence increases susceptibility to multiple sclerosis after accounting for established genetic and environmental risk factors

    PubMed Central

    Gianfrancesco, Milena A.; Acuna, Brigid; Shen, Ling; Briggs, Farren B.S.; Quach, Hong; Bellesis, Kalliope H.; Bernstein, Allan; Hedstrom, Anna K.; Kockum, Ingrid; Alfredsson, Lars; Olsson, Tomas; Schaefer, Catherine; Barcellos, Lisa F.

    2014-01-01

    Objective To investigate the association between obesity and multiple sclerosis (MS) while accounting for established genetic and environmental risk factors. Methods Participants included members of Kaiser Permanente Medical Care Plan, Northern California Region (KPNC) (1,235 MS cases and 697 controls). Logistic regression models were used to estimate odds ratios (ORs) with 95% confidence intervals (95% CI). Body mass index (BMI) or body size was the primary predictor of each model. Both incident and prevalent MS cases were studied. Results In analyses stratified by gender, being overweight at age 10 and 20 were associated with MS in females (p<0.01). Estimates trended in the same direction for males, but were not significant. BMI in 20’s demonstrated a linear relationship with MS (p-trend=9.60 × 10−4), and a twofold risk of MS for females with a BMI ≥ 30 kg/m2 was observed (OR = 2.15, 95% CI 1.18, 3.92). Significant associations between BMI in 20’s and MS in males were not observed. Multivariate modeling demonstrated that significant associations between BMI or body size with MS in females persisted after adjusting for history of infectious mononucleosis and genetic risk factors, including HLA-DRB1*15:01 and established non-HLA risk alleles. Interpretation Results show that childhood and adolescence obesity confer increased risk of MS in females beyond established heritable and environmental risk factors. Strong evidence for a dose-effect of BMI in 20’s and MS was observed. The magnitude of BMI association with MS is as large as other known MS risk factors. PMID:25263833

  17. Novel determination of polychlorinated naphthalenes in water by liquid chromatography-mass spectrometry with atmospheric pressure photoionization.

    PubMed

    Moukas, Athanasios I; Thomaidis, Nikolaos S; Calokerinos, Antony C

    2016-01-01

    This study presents the development, optimization, and validation of a novel method for the determination of polychlorinated naphthalenes (PCNs) by liquid chromatography-atmospheric pressure photoionization (APPI), using toluene as dopant. The mass spectra of PCN 52, 54, 66, 67, 73, and 75 were recorded in negative ionization. The base ions corresponded to [M-Cl+O](-), where M is the analyte molecule. A strategy, which includes designs of experiments, for the development, the evaluation, and the optimization of the LC-APPI-MS/MS methods is also described. Finally, a highly sensitive method with low instrumental limits of detection (LoDs), ranging from 0.8 pg for PCN 75 to 16 pg for PCN 54 on column, was validated. A Thermo Hypersil Green PAH (100 mm × 2.1 mm, 3 μm) column was used with acetonitrile/water/methanol as mobile phase. The method was applied for the determination of the selected PCNs in surface and tap water samples. A simple liquid-liquid extraction method for the extraction of PCNs from water samples was used. Method LoQs ranged from 29 ng L(-1), for PCN 73, to 63 ng L(-1), for PCN 54, and the recoveries ranged from 97 to 99%, for all congeners. This is the first LC-APPI-MS/MS method for the determination of PCNs in water samples.

  18. Analysis of 70 Environmental Protection Agency priority pharmaceuticals in water by EPA Method 1694.

    PubMed

    Ferrer, Imma; Zweigenbaum, Jerry A; Thurman, E Michael

    2010-09-03

    The U.S. Environmental Protection Agency (EPA) Method 1694 for the determination of pharmaceuticals in water recently brought a new challenge for treatment utilities, where pharmaceuticals have been reported in the drinking water of 41-million Americans. This proposed methodology, designed to address this important issue, consists of solid-phase extraction (SPE) followed by liquid chromatography-mass spectrometry (LC/MS-MS) using triple quadrupole. Under the guidelines of Method 1694, a multi-residue method was developed, validated, and applied to wastewater, surface water and drinking water samples for the analysis of 70 pharmaceuticals. Four distinct chromatographic gradients and LC conditions were used according to the polarity and extraction of the different pharmaceuticals. Positive and negative ion electrospray were used with two MRM transitions (a quantifier and a qualifier ion for each compound), which adds extra confirmation not included in the original Method 1694. Finally, we verify, for the first time, EPA Method 1694 on water samples collected in several locations in Colorado, where positive identifications for several pharmaceuticals were found. This study is a valuable indicator of the potential of LC/MS-MS for routine quantitative multi-residue analysis of pharmaceuticals in drinking water and wastewater samples and will make monitoring studies much easier to develop for water utilities across the US, who are currently seeking guidance on analytical methods for pharmaceuticals in their water supplies. 2010 Elsevier B.V. All rights reserved.

  19. Simultaneous Determination of 10 Ultratrace Elements in Infant Formula, Adult Nutritionals, and Milk Products by ICP/MS After Pressure Digestion: Single-Laboratory Validation.

    PubMed

    Dubascoux, Stephane; Nicolas, Marine; Rime, Celine Fragniere; Payot, Janique Richoz; Poitevin, Eric

    2015-01-01

    A single-laboratory validation (SLV) is presented for the simultaneous determination of 10 ultratrace elements (UTEs) including aluminum (Al), arsenic (As), cadmium (Cd), cobalt (Co), chromium (Cr), mercury (Hg), molybdenum (Mo), lead (Pb), selenium (Se), and tin (Sn) in infant formulas, adult nutritionals, and milk based products by inductively coupled plasma (ICP)/MS after acidic pressure digestion. This robust and routine multielemental method is based on several official methods with modifications of sample preparation using either microwave digestion or high pressure ashing and of analytical conditions using ICP/MS with collision cell technology. This SLV fulfills AOAC method performance criteria in terms of linearity, specificity, sensitivity, precision, and accuracy and fully answers most international regulation limits for trace contaminants and/or recommended nutrient levels established for 10 UTEs in targeted matrixes.

  20. Suspect screening of maternal serum to identify new environmental chemical biomonitoring targets using liquid chromatography-quadrupole time-of-flight mass spectrometry.

    PubMed

    Gerona, Roy R; Schwartz, Jackie M; Pan, Janet; Friesen, Matthew M; Lin, Thomas; Woodruff, Tracey J

    2018-03-01

    The use and advantages of high-resolution mass spectrometry (MS) as a discovery tool for environmental chemical monitoring has been demonstrated for environmental samples but not for biological samples. We developed a method using liquid chromatography-quadrupole time-of-flight MS (LC-QTOF/MS) for discovery of previously unmeasured environmental chemicals in human serum. Using non-targeted data acquisition (full scan MS analysis) we were able to screen for environmental organic acids (EOAs) in 20 serum samples from second trimester pregnant women. We define EOAs as environmental organic compounds with at least one dissociable proton which are utilized in commerce. EOAs include environmental phenols, phthalate metabolites, perfluorinated compounds, phenolic metabolites of polybrominated diphenyl ethers and polychlorinated biphenyls, and acidic pesticides and/or predicted acidic pesticide metabolites. Our validated method used solid phase extraction, reversed-phase chromatography in a C18 column with gradient elution, electrospray ionization in negative polarity and automated tandem MS (MS/MS) data acquisition to maximize true positive rates. We identified "suspect EOAs" using Agilent MassHunter Qualitative Analysis software, to match chemical formulas generated from each sample run with molecular formulas in our unique database of 693 EOAs assembled from multiple environmental literature sources. We found potential matches for 282 (41%) of the EOAs in our database. Sixty-five of these suspect EOAs were detected in at least 75% of the samples; only 19 of these compounds are currently biomonitored in National Health and Nutrition Examination Survey. We confirmed two of three suspect EOAs by LC-QTOF/MS using a targeted method developed through LC-MS/MS, reporting the first confirmation of benzophenone-1 and bisphenol S in pregnant women's sera. Our suspect screening workflow provides an approach to comprehensively scan environmental chemical exposures in humans. This can provide a better source of exposure information to help improve exposure and risk evaluation of industrial chemicals.

  1. Simultaneous Quantification of Seven Bioactive Flavonoids in Citri Reticulatae Pericarpium by Ultra-Fast Liquid Chromatography Coupled with Tandem Mass Spectrometry.

    PubMed

    Zhao, Lian-Hua; Zhao, Hong-Zheng; Zhao, Xue; Kong, Wei-Jun; Hu, Yi-Chen; Yang, Shi-Hai; Yang, Mei-Hua

    2016-05-01

    Citri Reticulatae Pericarpium (CRP) is a commonly-used traditional Chinese medicine with flavonoids as the major bioactive components. Nevertheless, the contents of the flavonoids in CRP of different sources may significantly vary affecting their therapeutic effects. Thus, the setting up of a reliable and comprehensive quality assessment method for flavonoids in CRP is necessary. To set up a rapid and sensitive ultra-fast liquid chromatography coupled with tandem mass spectrometry (UFLC-MS/MS) method for simultaneous quantification of seven bioactive flavonoids in CRP. A UFLC-MS/MS method coupled to ultrasound-assisted extraction was developed for simultaneous separation and quantification of seven flavonoids including hesperidin, neohesperidin, naringin, narirutin, tangeretin, nobiletin and sinensetin in 16 batches of CRP samples from different sources in China. The established method showed good linearity for all analytes with correlation coefficient (R) over 0.9980, together with satisfactory accuracy, precision and reproducibility. Furthermore, the recoveries at the three spiked levels were higher than 89.71% with relative standard deviations (RSDs) lower than 5.19%. The results indicated that the contents of seven bioactive flavonoids in CRP varied significantly among different sources. Among the samples under study, hesperidin showed the highest contents in 16 samples ranged from 27.50 to 86.30 mg/g, the contents of hesperidin in CRP-15 and CRP-9 were 27.50 and 86.30 mg/g, respectively, while, the amount of narirutin was too low to be measured in some samples. This study revealed that the developed UFLC-MS/MS method was simple, sensitive and reliable for simultaneous quantification of multi-components in CRP with potential perspective for quality control of complex matrices. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  2. Simultaneous quantitative determination of multiple bioactive markers in Ocimum sanctum obtained from different locations and its marketed herbal formulations using UPLC-ESI-MS/MS combined with principal component analysis.

    PubMed

    Pandey, Renu; Chandra, Preeti; Srivastava, Mukesh; Mishra, D K; Kumar, Brijesh

    2015-01-01

    Ocimum sanctum L., with phenolic acids, flavonoids, propenyl phenols and terpenoids as active pharmacological constituents, is a popular medicinal herb and is present as an ingredient in many herbal formulations. Therefore, development of a reliable analytical method for simultaneous determination of the pharmacologically active constituents of O. sanctum is of high importance. To develop and validate a new, rapid, sensitive and selective UPLC-ESI/MS/MS method for simultaneous determination of 23 bioactive markers including phenolic acids, flavonoids, propenyl phenol and terpenoid in the leaf extract and marketed herbal formulations of O. sanctum. An UPLC-ESI/MS/MS method using negative electrospray ionisation (ESI) in multiple-reaction-monitoring (MRM) mode was used for simultaneous determination. Chromatographic separation was achieved on an Acquity UPLC BEH C18 -column using a gradient elution with 0.1% formic acid in water and 0.1% formic acid in acetonitrile. Principal component analysis (PCA) was applied to correlate and discriminate eight geographical collections of O. sanctum based on quantitative data of the analytes. The developed method was validated as per International Conference on Harmonization guidelines and found to be accurate, with overall recovery in the range 95.09-104.84% (RSD ≤ 1.85%), precise (RSD ≤ 1.98%) and linear (r(2)  ≥ 0.9971) over the concentration range of 0.5-1000 ng/mL. Ursolic acid was found to be the most abundant marker in all the samples investigated, except for the marketed tablet. The method established is simple, rapid and sensitive, hence it can be reliably utilised for the quality control of O. sanctum and derived herbal formulations. Copyright © 2015 John Wiley & Sons, Ltd.

  3. Simplifying sample pretreatment: application of dried blood spot (DBS) method to blood samples, including postmortem, for UHPLC-MS/MS analysis of drugs of abuse.

    PubMed

    Odoardi, Sara; Anzillotti, Luca; Strano-Rossi, Sabina

    2014-10-01

    The complexity of biological matrices, such as blood, requires the development of suitably selective and reliable sample pretreatment procedures prior to their instrumental analysis. A method has been developed for the analysis of drugs of abuse and their metabolites from different chemical classes (opiates, methadone, fentanyl and analogues, cocaine, amphetamines and amphetamine-like substances, ketamine, LSD) in human blood using dried blood spot (DBS) and subsequent UHPLC-MS/MS analysis. DBS extraction required only 100μL of sample, added with the internal standards and then three droplets (30μL each) of this solution were spotted on the card, let dry for 1h, punched and extracted with methanol with 0.1% of formic acid. The supernatant was evaporated and the residue was then reconstituted in 100μL of water with 0.1% of formic acid and injected in the UHPLC-MS/MS system. The method was validated considering the following parameters: LOD and LOQ, linearity, precision, accuracy, matrix effect and dilution integrity. LODs were 0.05-1ng/mL and LOQs were 0.2-2ng/mL. The method showed satisfactory linearity for all substances, with determination coefficients always higher than 0.99. Intra and inter day precision, accuracy, matrix effect and dilution integrity were acceptable for all the studied substances. The addition of internal standards before DBS extraction and the deposition of a fixed volume of blood on the filter cards ensured the accurate quantification of the analytes. The validated method was then applied to authentic postmortem blood samples. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  4. Antifungal Susceptibility Testing of Aspergillus spp. by Using a Composite Correlation Index (CCI)-Based Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry Method Appears To Not Offer Benefit over Traditional Broth Microdilution Testing

    PubMed Central

    Gitman, Melissa R.; McTaggart, Lisa; Spinato, Joanna; Poopalarajah, Rahgavi; Lister, Erin; Husain, Shahid

    2017-01-01

    ABSTRACT Aspergillus spp. cause serious invasive lung infections, and Aspergillus fumigatus is the most commonly encountered clinically significant species. Voriconazole is considered to be the drug of choice for treating A. fumigatus infections; however, rising resistance rates have been reported. We evaluated a matrix-assisted laser desorption ionization–time of flight mass spectrometry (MALDI-TOF MS)-based method for the differentiation between wild-type and non-wild-type isolates of 20 Aspergillus spp. (including 2 isolates of Aspergillus ustus and 1 of Aspergillus calidoustus that were used as controls due their intrinsic low azole susceptibility with respect to the in vitro response to voriconazole). At 30 and 48 h of incubation, there was complete agreement between Cyp51A sequence analysis, broth microdilution, and MALDI-TOF MS classification of isolates as wild type or non-wild type. In this proof-of-concept study, we demonstrated that MALDI-TOF MS can be used to accurately detect A. fumigatus strains with reduced voriconazole susceptibility. However, rather than proving to be a rapid and simple method for antifungal susceptibility testing, this particular MS-based method showed no benefit over conventional testing methods. PMID:28404678

  5. Antifungal Susceptibility Testing of Aspergillus spp. by Using a Composite Correlation Index (CCI)-Based Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry Method Appears To Not Offer Benefit over Traditional Broth Microdilution Testing.

    PubMed

    Gitman, Melissa R; McTaggart, Lisa; Spinato, Joanna; Poopalarajah, Rahgavi; Lister, Erin; Husain, Shahid; Kus, Julianne V

    2017-07-01

    Aspergillus spp. cause serious invasive lung infections, and Aspergillus fumigatus is the most commonly encountered clinically significant species. Voriconazole is considered to be the drug of choice for treating A. fumigatus infections; however, rising resistance rates have been reported. We evaluated a matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS)-based method for the differentiation between wild-type and non-wild-type isolates of 20 Aspergillus spp. (including 2 isolates of Aspergillus ustus and 1 of Aspergillus calidoustus that were used as controls due their intrinsic low azole susceptibility with respect to the in vitro response to voriconazole). At 30 and 48 h of incubation, there was complete agreement between Cyp51A sequence analysis, broth microdilution, and MALDI-TOF MS classification of isolates as wild type or non-wild type. In this proof-of-concept study, we demonstrated that MALDI-TOF MS can be used to accurately detect A. fumigatus strains with reduced voriconazole susceptibility. However, rather than proving to be a rapid and simple method for antifungal susceptibility testing, this particular MS-based method showed no benefit over conventional testing methods. © Crown copyright 2017.

  6. Development and validation of a quantitative UHPLC-MS/MS method for selected brominated flame retardants in food.

    PubMed

    Malysheva, Svetlana V; Goscinny, Séverine; Malarvannan, Govindan; Poma, Giulia; Andjelkovic, Mirjana; Voorspoels, Stefan; Covaci, Adrian; Van Loco, Joris

    2018-02-01

    An ultra-high performance liquid chromatography - tandem mass spectrometry (UHPLC-MS/MS) method was developed and validated (in-house) for the quantification of selected brominated flame retardants (BFRs), including tetrabromobisphenol A (TBBPA), hexabromocyclododecanes (HBCDs), tetrabromobisphenol S (TBBPS) and bromophenols (BPs), in various food matrices. The sample preparation consisted of extraction of TBBPS with acidified acetonitrile followed by a fast dispersive solid-phase extraction (dSPE) clean-up and extraction of the other BFRs with a mixture of hexane and dichloromethane (1:1, v/v) with subsequent clean-up using acidified silica (44%, w/w). The limits of quantification of the method varied widely for the types of food matrices and the different classes of BFRs from 4 pg g -1 wet weight (ww) to 8 ng g -1 ww. For most of the analytes the apparent recovery was in the range 70-120%, and the method precision (under repeatability conditions) was below 20%. The method was successfully applied in proficiency testing exercises as well as for analysis of various food items. Only 25% of the collected food samples contained BFRs, with 4-bromophenol and α-HBCD as the only detected compounds. The contaminated foodstuffs were fish and eggs with concentrations in the range from 48 to 305 pg g -1 ww.

  7. Quantification of Neural Ethanol and Acetaldehyde Using Headspace GC-MS

    PubMed Central

    Heit, Claire; Eriksson, Peter; Thompson, David C; Fritz, Kristofer S; Vasiliou, Vasilis

    2016-01-01

    BACKGROUND There is controversy regarding the active agent responsible for alcohol addiction. The theory that ethanol itself was the agent in alcohol drinking behavior was widely accepted until acetaldehyde was found in the brain. The importance of acetaldehyde formation in the brain role is still subject to speculation due to the lack of a method to accurately assay the acetaldehyde levels directly. A highly sensitive GC-MS method to reliably determine acetaldehyde concentration with certainty is needed to address whether neural acetaldehyde is indeed responsible for increased alcohol consumption. METHODS A headspace gas chromatograph coupled to selected ion monitoring mass spectrometry was utilized to develop a quantitative assay for acetaldehyde and ethanol. Our GC-MS approach was carried out using a Bruker Scion 436-GC SQ MS. RESULTS Our approach yields limits of detection of acetaldehyde in the nanomolar range and limits of quantification in the low micromolar range. Our linear calibration includes 5 concentrations with a least square regression greater than 0.99 for both acetaldehyde and ethanol. Tissue analyses using this method revealed the capacity to quantify ethanol and acetaldehyde in blood, brain, and liver tissue from mice. CONCLUSIONS By allowing quantification of very low concentrations, this method may be used to examine the formation of ethanol metabolites, specifically acetaldehyde, in murine brain tissue in alcohol research. PMID:27501276

  8. Simultaneous monitoring of oxidation, deamidation, isomerization, and glycosylation of monoclonal antibodies by liquid chromatography-mass spectrometry method with ultrafast tryptic digestion.

    PubMed

    Wang, Yi; Li, Xiaojuan; Liu, Yan-Hui; Richardson, Daisy; Li, Huijuan; Shameem, Mohammed; Yang, Xiaoyu

    Monoclonal antibodies are subjected to a wide variety of post-translational modifications (PTMs) that cause structural heterogeneity. Characterization and control of these modifications or quality attributes are critical to ensure antibody quality and to define any potential effects on the ultimate safety and potency of antibody therapeutics. The biopharmaceutical industry currently uses numerous tools to analyze these quality attributes individually, which requires substantial time and resources. Here, we report a simple and ultrafast bottom-up liquid chromatography-mass spectrometry (uLC-MS) method with 5 min tryptic digestion to simultaneously analyze multiple modifications, including oxidation, deamidation, isomerization, glycation, glycosylation, and N-terminal pyro-glutamate formation, which can occur during antibody production in mammalian cell culture, during purification and/or on storage. Compared to commonly used preparation procedures, this uLC-MS method eliminates assay artifacts of falsely-increased Met oxidation, Asp isomerization, and Asn deamidation, a problem associated with long digestion times in conventional LC-MS methods. This simple, low artifact multi-attribute uLC-MS method can be used to quickly and accurately analyze samples at any stage of antibody drug development, in particular for clone and media selection during cell culture development.

  9. Development and comparison of HPLC-MS/MS and UPLC-MS/MS methods for determining eight coccidiostats in beef.

    PubMed

    Zhao, Xia; Wang, Bo; Xie, Kaizhou; Liu, Jianyu; Zhang, Yangyang; Wang, Yajuan; Guo, Yawen; Zhang, Genxi; Dai, Guojun; Wang, Jinyu

    2018-06-15

    A high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method and an ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for determining eight coccidiostat (halofuginone, lasalocid, maduramicin, monensin, narasin, nigericin, robenidine and salinomycin) residues in beef were developed and compared. Samples were extracted with a mixture of acetic acid, acetonitrile and ethyl acetate and were then purified on a C 18 solid-phase extraction (SPE) column. The purified samples were analyzed by HPLC-MS/MS and UPLC-MS/MS, using 0.1% formic acid-water solution (A) and pure methanol (B) as the mobile phase. The samples were fractionated on a C 18 column using different gradient elution procedures, followed by qualitative analysis using a mass spectrometer operated in multiple reaction monitoring (MRM) mode with positive electrospray ionization; the external standard method was used for quantitation. At spiked levels that ranged from the limit of quantification (LOQ) to 100 μg/kg, the average recoveries were 71.96%-100.32% and 71.24%-89.24%, with relative standard deviations (RSDs) of 2.65%-12.38% and 2.98%-14.86% for UPLC-MS/MS and HPLC-MS/MS, respectively. The limits of detection (LODs) and LOQs of the eight coccidiostats were 0.14-0.32 μg/kg and 0.43-1.21 μg/kg, respectively, for UPLC-MS/MS analysis and 0.16-0.58 μg/kg and 0.53-1.92 μg/kg, respectively, for HPLC-MS/MS analysis. Both methods had good accuracy and precision, but UPLC-MS/MS had higher sensitivity than HPLC-MS/MS. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. Comparison of sample preparation techniques and data analysis for the LC-MS/MS-based identification of proteins in human follicular fluid.

    PubMed

    Lehmann, Roland; Schmidt, André; Pastuschek, Jana; Müller, Mario M; Fritzsche, Andreas; Dieterle, Stefan; Greb, Robert R; Markert, Udo R; Slevogt, Hortense

    2018-06-25

    The proteomic analysis of complex body fluids by liquid chromatography tandem mass spectrometry (LC-MS/MS) analysis requires the selection of suitable sample preparation techniques and optimal parameter settings in data analysis software packages to obtain reliable results. Proteomic analysis of follicular fluid, as a representative of a complex body fluid similar to serum or plasma, is difficult as it contains a vast amount of high abundant proteins and a variety of proteins with different concentrations. However, the accessibility of this complex body fluid for LC-MS/MS analysis is an opportunity to gain insights into the status, the composition of fertility-relevant proteins including immunological factors or for the discovery of new diagnostic and prognostic markers for, for example, the treatment of infertility. In this study, we compared different sample preparation methods (FASP, eFASP and in-solution digestion) and three different data analysis software packages (Proteome Discoverer with SEQUEST, Mascot and MaxQuant with Andromeda) combined with semi- and full-tryptic databank search options to obtain a maximum coverage of the follicular fluid proteome. We found that the most comprehensive proteome coverage is achieved by the eFASP sample preparation method using SDS in the initial denaturing step and the SEQUEST-based semi-tryptic data analysis. In conclusion, we have developed a fractionation-free methodical workflow for in depth LC-MS/MS-based analysis for the standardized investigation of human follicle fluid as an important representative of a complex body fluid. Taken together, we were able to identify a total of 1392 proteins in follicular fluid. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  11. A method for the determination of acrylamide in a broad variety of processed foods by GC-MS using xanthydrol derivatization.

    PubMed

    Yamazaki, Kumiko; Isagawa, Satoshi; Kibune, Nobuyuki; Urushiyama, Tetsuo

    2012-01-01

    A novel GC-MS method was developed for the determination of acrylamide, which is applicable to a variety of processed foods, including potato snacks, corn snacks, biscuits, instant noodles, coffee, soy sauces and miso (fermented soy bean paste). The method involves the derivatization of acrylamide with xanthydrol instead of a bromine compound. Isotopically labelled acrylamide (d₃-acrylamide) was used as the internal standard. The aqueous extract from samples was purified using Sep-Pak™ C₁₈ and Sep-Pak™ AC-2 columns. For amino acid-rich samples, such as miso or soy sauce, an Extrelut™ column was used for purification or extraction. After reaction with xanthydrol, the resultant N-xanthyl acrylamide was determined by GC-MS. The method was validated for various food matrices and showed good linearity, precision and trueness. The limit of detection and limit of quantification ranged 0.5-5 and 5-20 µg kg⁻¹), respectively. The developed method was applied as an exploratory survey of acrylamide in Japanese foods and the method was shown to be applicable for all samples tested.

  12. Platform-independent and label-free quantitation of proteomic data using MS1 extracted ion chromatograms in skyline: application to protein acetylation and phosphorylation.

    PubMed

    Schilling, Birgit; Rardin, Matthew J; MacLean, Brendan X; Zawadzka, Anna M; Frewen, Barbara E; Cusack, Michael P; Sorensen, Dylan J; Bereman, Michael S; Jing, Enxuan; Wu, Christine C; Verdin, Eric; Kahn, C Ronald; Maccoss, Michael J; Gibson, Bradford W

    2012-05-01

    Despite advances in metabolic and postmetabolic labeling methods for quantitative proteomics, there remains a need for improved label-free approaches. This need is particularly pressing for workflows that incorporate affinity enrichment at the peptide level, where isobaric chemical labels such as isobaric tags for relative and absolute quantitation and tandem mass tags may prove problematic or where stable isotope labeling with amino acids in cell culture labeling cannot be readily applied. Skyline is a freely available, open source software tool for quantitative data processing and proteomic analysis. We expanded the capabilities of Skyline to process ion intensity chromatograms of peptide analytes from full scan mass spectral data (MS1) acquired during HPLC MS/MS proteomic experiments. Moreover, unlike existing programs, Skyline MS1 filtering can be used with mass spectrometers from four major vendors, which allows results to be compared directly across laboratories. The new quantitative and graphical tools now available in Skyline specifically support interrogation of multiple acquisitions for MS1 filtering, including visual inspection of peak picking and both automated and manual integration, key features often lacking in existing software. In addition, Skyline MS1 filtering displays retention time indicators from underlying MS/MS data contained within the spectral library to ensure proper peak selection. The modular structure of Skyline also provides well defined, customizable data reports and thus allows users to directly connect to existing statistical programs for post hoc data analysis. To demonstrate the utility of the MS1 filtering approach, we have carried out experiments on several MS platforms and have specifically examined the performance of this method to quantify two important post-translational modifications: acetylation and phosphorylation, in peptide-centric affinity workflows of increasing complexity using mouse and human models.

  13. Platform-independent and Label-free Quantitation of Proteomic Data Using MS1 Extracted Ion Chromatograms in Skyline

    PubMed Central

    Schilling, Birgit; Rardin, Matthew J.; MacLean, Brendan X.; Zawadzka, Anna M.; Frewen, Barbara E.; Cusack, Michael P.; Sorensen, Dylan J.; Bereman, Michael S.; Jing, Enxuan; Wu, Christine C.; Verdin, Eric; Kahn, C. Ronald; MacCoss, Michael J.; Gibson, Bradford W.

    2012-01-01

    Despite advances in metabolic and postmetabolic labeling methods for quantitative proteomics, there remains a need for improved label-free approaches. This need is particularly pressing for workflows that incorporate affinity enrichment at the peptide level, where isobaric chemical labels such as isobaric tags for relative and absolute quantitation and tandem mass tags may prove problematic or where stable isotope labeling with amino acids in cell culture labeling cannot be readily applied. Skyline is a freely available, open source software tool for quantitative data processing and proteomic analysis. We expanded the capabilities of Skyline to process ion intensity chromatograms of peptide analytes from full scan mass spectral data (MS1) acquired during HPLC MS/MS proteomic experiments. Moreover, unlike existing programs, Skyline MS1 filtering can be used with mass spectrometers from four major vendors, which allows results to be compared directly across laboratories. The new quantitative and graphical tools now available in Skyline specifically support interrogation of multiple acquisitions for MS1 filtering, including visual inspection of peak picking and both automated and manual integration, key features often lacking in existing software. In addition, Skyline MS1 filtering displays retention time indicators from underlying MS/MS data contained within the spectral library to ensure proper peak selection. The modular structure of Skyline also provides well defined, customizable data reports and thus allows users to directly connect to existing statistical programs for post hoc data analysis. To demonstrate the utility of the MS1 filtering approach, we have carried out experiments on several MS platforms and have specifically examined the performance of this method to quantify two important post-translational modifications: acetylation and phosphorylation, in peptide-centric affinity workflows of increasing complexity using mouse and human models. PMID:22454539

  14. LC-MS-sMRM Method Development and Validation of Different Classes of Pain Panel Drugs and Analysis of Clinical Urine Samples.

    PubMed

    Athar Masood, M; Veenstra, Timothy D

    2017-08-26

    Urine Drug Testing (UDT) is an important analytical/bio-analytical technique that has inevitably become an integral and vital part of a testing program for diagnostic purposes. This manuscript presents a tailor-made LC-MS/MS quantitative assay method development and validation for a custom group of 33 pain panel drugs and their metabolites belonging to different classes (opiates, opioids, benzodiazepines, illicit, amphetamines, etc.) that are prescribed in pain management and depressant therapies. The LC-MS/MS method incorporates two experiments to enhance the sensitivity of the assay and has a run time of about 7 min. with no prior purification of the samples required and a flow rate of 0.7 mL/min. The method also includes the second stage metabolites for some drugs that belong to different classes but have first stage similar metabolic pathways that will enable to correctly identify the right drug or to flag the drug that might be due to specimen tampering. Some real case examples and difficulties in peak picking were provided with some of the analytes in subject samples. Finally, the method was deliberated with some randomly selected de-identified clinical subject samples, and the data evaluated from "direct dilute and shoot analysis" and after "glucuronide hydrolysis" were compared. This method is now used to run routinely more than 100 clinical subjects samples on a daily basis. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  15. Validation of a LC-MS/MS Method for Quantifying Urinary Nicotine, Six Nicotine Metabolites and the Minor Tobacco Alkaloids—Anatabine and Anabasine—in Smokers' Urine

    PubMed Central

    McGuffey, James E.; Wei, Binnian; Bernert, John T.; Morrow, John C.; Xia, Baoyun; Wang, Lanqing; Blount, Benjamin C.

    2014-01-01

    Tobacco use is a major contributor to premature morbidity and mortality. The measurement of nicotine and its metabolites in urine is a valuable tool for evaluating nicotine exposure and for nicotine metabolic profiling—i.e., metabolite ratios. In addition, the minor tobacco alkaloids—anabasine and anatabine—can be useful for monitoring compliance in smoking cessation programs that use nicotine replacement therapy. Because of an increasing demand for the measurement of urinary nicotine metabolites, we developed a rapid, low-cost method that uses isotope dilution liquid chromatography-tandem mass spectrometry (LC-MS/MS) for simultaneously quantifying nicotine, six nicotine metabolites, and two minor tobacco alkaloids in smokers' urine. This method enzymatically hydrolyzes conjugated nicotine (primarily glucuronides) and its metabolites. We then use acetone pretreatment to precipitate matrix components (endogenous proteins, salts, phospholipids, and exogenous enzyme) that may interfere with LC-MS/MS analysis. Subsequently, analytes (nicotine, cotinine, hydroxycotinine, norcotinine, nornicotine, cotinine N-oxide, nicotine 1′-N-oxide, anatabine, and anabasine) are chromatographically resolved within a cycle time of 13.5 minutes. The optimized assay produces linear responses across the analyte concentrations typically found in urine collected from daily smokers. Because matrix ion suppression may influence accuracy, we include a discussion of conventions employed in this procedure to minimize matrix interferences. Simplicity, low cost, low maintenance combined with high mean metabolite recovery (76–99%), specificity, accuracy (0–10% bias) and reproducibility (2–9% C.V.) make this method ideal for large high through-put studies. PMID:25013964

  16. A method of analysis for T-2 toxin and neosolaniol by UPLC-MS/MS in apple fruit inoculated with Trichothecium roseum.

    PubMed

    Tang, Yamei; Xue, Huali; Bi, Yang; Li, Yongcai; Wang, Yi; Zhao, Ying; Shen, Keping

    2015-01-01

    Trichothecenes are one of the most important groups of mycotoxins produced by Trichothecium roseum, which causes core rot of apple. A reliable and sensitive method was developed and successfully applied for the rapid detection of trichothecenes including T-2 toxin and neosolaniol in harvested apple using UPLC-MS/MS. After the extraction of the two mycotoxins from the apple matrix with methanol/water (80/20, v/v), the concentrated extracts were cleaned-up by PriboFast M270 columns and then analysed by UPLC-MS/MS. T-2 toxin and neosolaniol were effectively separated as unique peaks. The validity of this method was established by its linearity (R(2) ≥ 0.9995), precision (relative standard deviation ≤ 3.6%), accuracy, selectivity, limit of detection of 2-5 μg kg(-1), limit of quantification of 5-10 μg kg(-1) and average recovery of 73-96%. Levels of T-2 toxin were found in the range 7.1-128.4 µg kg(-1) in the core rot lesion of three cultivars apple (cvs. Red Delicious, Fuji and Ralls). T-2 was detected not only in the lesion, but also in the tissue without any disease symptoms. However, neosolaniol was only detected in the lesion on 'Red Delicious' apples. In addition, the concentration of T-2 toxin in the susceptible cultivar (cv. Fuji) was significantly higher than that in the resistant one (cv. Ralls). This method proved to be suitable at detecting T-2 and neosolaniol simultaneously in apples infected with T. roseum.

  17. Determination and quantification of active phenolic compounds in pigeon pea leaves and its medicinal product using liquid chromatography–tandem mass spectrometry.

    PubMed

    Liu, Wei; Kong, Yu; Zu, Yuangang; Fu, Yujie; Luo, Meng; Zhang, Lin; Li, Ji

    2010-07-09

    A novel method using liquid chromatography coupled to electrospray ionization mass spectrometry (LC-ESI-MS) has been optimized and established for the qualitative and quantitative analysis of ten active phenolic compounds originating from the pigeon pea leaves and a medicinal product thereof (Tongluo Shenggu capsules). In the present study, the chromatographic separation was achieved by means of a HiQ Sil C18V reversed-phase column with a mobile phase consisting of methanol and 0.1% formic acid aqueous solution. Low-energy collision-induced dissociation tandem mass spectrometry (CID-MS/MS) using the selected reaction monitoring (SRM) analysis was employed for the detection of ten analytes which included six flavonoids, two isoflavonoids and two stilbenes. All calibration curves showed excellent coefficients of determination (r(2) ≥ 0.9937) within the range of tested concentrations. The intra- and inter-day variations were below 5.36% in terms of relative standard deviation (RSD). The recoveries were 95.08-104.98% with RSDs of 2.06-4.26% for spiked samples of pigeon pea leaves. The method developed was a rapid, efficient and accurate LC-MS/MS method for the detection of phenolic compounds, which can be applied for quality control of pigeon pea leaves and related medicinal products.

  18. Chip-based nanoflow high performance liquid chromatography coupled to mass spectrometry for profiling of soybean flavonoids.

    PubMed

    Chang, Yuwei; Zhao, Chunxia; Wu, Zeming; Zhou, Jia; Zhao, Sumin; Lu, Xin; Xu, Guowang

    2012-08-01

    In this work a chip-based nano HPLC coupled MS (HPLC-chip/MS) method with a simple sample preparation procedure was developed for the flavonoid profiling of soybean. The analytical properties of the method including the linearity (R(2) , 0.992-0.995), reproducibility (RSD, 1.50-7.66%), intraday precision (RSD, 1.41-5.14%) and interday precision (RSD, 2.76-16.90%) were satisfactory. Compared with the conventional HPLC/MS method, a fast extraction and analysis procedure was applied and more flavonoids were detected in a single run. Additionally, 13 flavonoids in soybean seed were identified for the first time. The method was then applied to the profiling of six varieties of soybean sowed at the same place. A clear discrimination was observed among different cultivars, three isoflavones, accounting for nearly 80% of total flavonoid contents, were found increased in the spring soybeans compared with the summer cultivars. © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. The challenge of comorbidity in clinical trials for multiple sclerosis

    PubMed Central

    Miller, Aaron; Sormani, Maria Pia; Thompson, Alan; Waubant, Emmanuelle; Trojano, Maria; O'Connor, Paul; Reingold, Stephen; Cohen, Jeffrey A.

    2016-01-01

    Objective: We aimed to provide recommendations for addressing comorbidity in clinical trial design and conduct in multiple sclerosis (MS). Methods: We held an international workshop, informed by a systematic review of the incidence and prevalence of comorbidity in MS and an international survey about research priorities for studying comorbidity including their relation to clinical trials in MS. Results: We recommend establishing age- and sex-specific incidence estimates for comorbidities in the MS population, including those that commonly raise concern in clinical trials of immunomodulatory agents; shifting phase III clinical trials of new therapies from explanatory to more pragmatic trials; describing comorbidity status of the enrolled population in publications reporting clinical trials; evaluating treatment response, tolerability, and safety in clinical trials according to comorbidity status; and considering comorbidity status in the design of pharmacovigilance strategies. Conclusion: Our recommendations will help address knowledge gaps regarding comorbidity that interfere with the ability to interpret safety in monitored trials and will enhance the generalizability of findings from clinical trials to “real world” settings where the MS population commonly has comorbid conditions. PMID:26888986

  20. Comparison of Quantitative Mass Spectrometry Platforms for Monitoring Kinase ATP Probe Uptake in Lung Cancer.

    PubMed

    Hoffman, Melissa A; Fang, Bin; Haura, Eric B; Rix, Uwe; Koomen, John M

    2018-01-05

    Recent developments in instrumentation and bioinformatics have led to new quantitative mass spectrometry platforms including LC-MS/MS with data-independent acquisition (DIA) and targeted analysis using parallel reaction monitoring mass spectrometry (LC-PRM), which provide alternatives to well-established methods, such as LC-MS/MS with data-dependent acquisition (DDA) and targeted analysis using multiple reaction monitoring mass spectrometry (LC-MRM). These tools have been used to identify signaling perturbations in lung cancers and other malignancies, supporting the development of effective kinase inhibitors and, more recently, providing insights into therapeutic resistance mechanisms and drug repurposing opportunities. However, detection of kinases in biological matrices can be challenging; therefore, activity-based protein profiling enrichment of ATP-utilizing proteins was selected as a test case for exploring the limits of detection of low-abundance analytes in complex biological samples. To examine the impact of different MS acquisition platforms, quantification of kinase ATP uptake following kinase inhibitor treatment was analyzed by four different methods: LC-MS/MS with DDA and DIA, LC-MRM, and LC-PRM. For discovery data sets, DIA increased the number of identified kinases by 21% and reduced missingness when compared with DDA. In this context, MRM and PRM were most effective at identifying global kinome responses to inhibitor treatment, highlighting the value of a priori target identification and manual evaluation of quantitative proteomics data sets. We compare results for a selected set of desthiobiotinylated peptides from PRM, MRM, and DIA and identify considerations for selecting a quantification method and postprocessing steps that should be used for each data acquisition strategy.

  1. PER3 VNTR polymorphism in Multiple Sclerosis: A new insight to impact of sleep disturbances in MS.

    PubMed

    Golalipour, Masoud; Maleki, Zahra; Farazmandfar, Touraj; Shahbazi, Majid

    2017-10-01

    Multiple Sclerosis (MS) is a degenerative disease of central nervous system caused by an immune response against the myelin. About half of MS patients suffers from sleep disturbances. The circadian clock genes such as PER3 controls circadian rhythm and sleep. Due to the role of PER3 in sleep disturbances and regulation of immune response, it is possible that PER3 dysregulation increase risk of MS disease. Study groups included 160 MS patients and 160 healthy volunteers. PER3 VNTR polymorphism was evaluated by PCR method. The genotypic and allelic distribution analyzed by chi square test. There was a significant association between genotype PER3 4/4 , and 4-repeat allele with MS disease (p = 0.014 and p < 0.001 respectively). The association analysis of PER3 VNTR polymorphism with gender status among MS group, and MS onset showed that there was a significant correlation between PER3 4/4 genotype with female gender and early onset of MS disease (p = 0.033 and p = 0.028 respectively). Our data suggest that, PER3 4/4 genotype may accelerate the course of disease in MS susceptible individuals. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. MRI T2 Mapping of the Knee Articular Cartilage Using Different Acquisition Sequences and Calculation Methods at 1.5 Tesla.

    PubMed

    Mars, Mokhtar; Bouaziz, Mouna; Tbini, Zeineb; Ladeb, Fethi; Gharbi, Souha

    2018-06-12

    This study aims to determine how Magnetic Resonance Imaging (MRI) acquisition techniques and calculation methods affect T2 values of knee cartilage at 1.5 Tesla and to identify sequences that can be used for high-resolution T2 mapping in short scanning times. This study was performed on phantom and twenty-nine patients who underwent MRI of the knee joint at 1.5 Tesla. The protocol includes T2 mapping sequences based on Single Echo Spin Echo (SESE), Multi-Echo Spin Echo (MESE), Fast Spin Echo (FSE) and Turbo Gradient Spin Echo (TGSE). The T2 relaxation times were quantified and evaluated using three calculation methods (MapIt, Syngo Offline and monoexponential fit). Signal to Noise Ratios (SNR) were measured in all sequences. All statistical analyses were performed using the t-test. The average T2 values in phantom were 41.7 ± 13.8 ms for SESE, 43.2 ± 14.4 ms for MESE, 42.4 ± 14.1 ms for FSE and 44 ± 14.5 ms for TGSE. In the patient study, the mean differences were 6.5 ± 8.2 ms, 7.8 ± 7.6 ms and 8.4 ± 14.2 ms for MESE, FSE and TGSE compared to SESE respectively; these statistical results were not significantly different (p > 0.05). The comparison between the three calculation methods showed no significant difference (p > 0.05). t-Test showed no significant difference between SNR values for all sequences. T2 values depend not only on the sequence type but also on the calculation method. None of the sequences revealed significant differences compared to the SESE reference sequence. TGSE with its short scanning time can be used for high-resolution T2 mapping. ©2018The Author(s). Published by S. Karger AG, Basel.

  3. Imaging outcome measures for progressive multiple sclerosis trials

    PubMed Central

    Moccia, Marcello; de Stefano, Nicola; Barkhof, Frederik

    2017-01-01

    Imaging markers that are reliable, reproducible and sensitive to neurodegenerative changes in progressive multiple sclerosis (MS) can enhance the development of new medications with a neuroprotective mode-of-action. Accordingly, in recent years, a considerable number of imaging biomarkers have been included in phase 2 and 3 clinical trials in primary and secondary progressive MS. Brain lesion count and volume are markers of inflammation and demyelination and are important outcomes even in progressive MS trials. Brain and, more recently, spinal cord atrophy are gaining relevance, considering their strong association with disability accrual; ongoing improvements in analysis methods will enhance their applicability in clinical trials, especially for cord atrophy. Advanced magnetic resonance imaging (MRI) techniques (e.g. magnetization transfer ratio (MTR), diffusion tensor imaging (DTI), spectroscopy) have been included in few trials so far and hold promise for the future, as they can reflect specific pathological changes targeted by neuroprotective treatments. Position emission tomography (PET) and optical coherence tomography have yet to be included. Applications, limitations and future perspectives of these techniques in clinical trials in progressive MS are discussed, with emphasis on measurement sensitivity, reliability and sample size calculation. PMID:29041865

  4. Head-to-head comparison of Microflex LT and Vitek MS systems for routine identification of microorganisms by MALDI-TOF mass spectrometry in Chile

    PubMed Central

    García, Patricia; Braun, Stephanie; Ulloa, María Teresa; Lafourcade, Mónica; Montaña, Alisson; Miranda, Carolina; Acosta-Jamett, Gerardo; Weitzel, Thomas

    2017-01-01

    Background Matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry (MS) is a new and revolutionary identification method for microorganisms and has recently been introduced into clinical microbiology in many industrialized countries in Europe and North America. Objectives Our study aimed to compare the performance and practicality of two commercial MALDI-TOF MS platforms in a head-to head manner at a routine laboratory in Chile. Methods During a five-month period in 2012–13, the diagnostic efficiency (correct identification rate) and agreement between Microflex LT (Bruker Daltonics) and Vitek MS (bioMérieux) was compared in a parallel manner to conventional identification including genotypic analysis for difficult-to-identify strains. The study included 804 microbial isolates: 252 Enterobacteriaceae, 126 non-fermenters, 36 other gram-negative rods, 279 gram-positive cocci, 32 gram-positive rods, 32 anaerobes, and 47 yeasts. Other relevant factors of the two devices such as user friendliness and connectivity were also evaluated and compared. Results Both systems correctly identified the vast majority (98%) of the isolates to the genus level. Vitek MS reached higher rates of identification to species and species complex level than Microflex LT (81% vs. 85% and 87% vs. 93%, respectively), which was mainly based on the higher performance among coagulase negative staphylococci and Candida isolates. The evaluation of user friendliness and other technical aspects showed only marginal differences, which slightly favored Vitek MS, mainly due to its ready-to-use supplies, easier connectivity and workflow integration, and availability of local technical support. Conclusions Both MALDI-TOF MS systems permitted fast and accurate identification of most microbial strains and showed a high level of user-friendliness. The observed differences were marginal and slightly favored Vitek MS, mainly due to practicality and connectivity issues within our setting. PMID:28542393

  5. Characterization of N-palmitoylated human growth hormone by in situ liquid-liquid extraction and MALDI tandem mass spectrometry.

    PubMed

    Sachon, Emmanuelle; Nielsen, Per Franklin; Jensen, Ole Nørregaard

    2007-06-01

    Acylation is a common post-translational modification found in secreted proteins and membrane-associated proteins, including signal transducing and regulatory proteins. Acylation is also explored in the pharmaceutical and biotechnology industry to increase the stability and lifetime of protein-based products. The presence of acyl moieties in proteins and peptides affects the physico-chemical properties of these species, thereby modulating protein stability, function, localization and molecular interactions. Characterization of protein acylation is a challenging analytical task, which includes the precise definition of the acylation sites in proteins and determination of the identity and molecular heterogeneity of the acyl moiety at each individual site. In this study, we generated a chemically modified human growth hormone (hGH) by incorporation of a palmitoyl moiety on the N(epsilon) group of a lysine residue. Monoacylation of the hGH protein was confirmed by determination of the intact molecular weight by mass spectrometry. Detailed analysis of protein acylation was achieved by analysis of peptides derived from hGH by protease treatment. However, peptide mass mapping by MALDI MS using trypsin and AspN proteases and standard sample preparation methods did not reveal any palmitoylated peptides. In contrast, in situ liquid-liquid extraction (LLE) performed directly on the MALDI MS metal target enabled detection of acylated peptide candidates by MALDI MS and demonstrated that hGH was N-palmitoylated at multiple lysine residues. MALDI MS and MS/MS analysis of the modified peptides mapped the N-palmitoylation sites to Lys158, Lys172 and Lys140 or Lys145. This study demonstrates the utility of LLE/MALDI MS/MS for mapping and characterization of acylation sites in proteins and peptides and the importance of optimizing sample preparation methods for mass spectrometry-based determination of substoichiometric, multi-site protein modifications.

  6. The great importance of normalization of LC-MS data for highly-accurate non-targeted metabolomics.

    PubMed

    Mizuno, Hajime; Ueda, Kazuki; Kobayashi, Yuta; Tsuyama, Naohiro; Todoroki, Kenichiro; Min, Jun Zhe; Toyo'oka, Toshimasa

    2017-01-01

    The non-targeted metabolomics analysis of biological samples is very important to understand biological functions and diseases. LC combined with electrospray ionization-based MS has been a powerful tool and widely used for metabolomic analyses. However, the ionization efficiency of electrospray ionization fluctuates for various unexpected reasons such as matrix effects and intraday variations of the instrument performances. To remove these fluctuations, normalization methods have been developed. Such techniques include increasing the sensitivity, separating co-eluting components and normalizing the ionization efficiencies. Normalization techniques allow simultaneously correcting of the ionization efficiencies of the detected metabolite peaks and achieving quantitative non-targeted metabolomics. In this review paper, we focused on these normalization methods for non-targeted metabolomics by LC-MS. Copyright © 2016 John Wiley & Sons, Ltd.

  7. Development of High-Performance Chemical Isotope Labeling LC-MS for Profiling the Carbonyl Submetabolome.

    PubMed

    Zhao, Shuang; Dawe, Margot; Guo, Kevin; Li, Liang

    2017-06-20

    Metabolites containing a carbonyl group represent several important classes of molecules including various forms of ketones and aldehydes such as steroids and sugars. We report a high-performance chemical isotope labeling (CIL) LC-MS method for profiling the carbonyl submetabolome with high coverage and high accuracy and precision of relative quantification. This method is based on the use of dansylhydrazine (DnsHz) labeling of carbonyl metabolites to change their chemical and physical properties to such an extent that the labeled metabolites can be efficiently separated by reversed phase LC and ionized by electrospray ionization MS. In the analysis of six standards representing different carbonyl classes, acetaldehyde could be ionized only after labeling and MS signals were significantly increased for other 5 standards with an enhancement factor ranging from ∼15-fold for androsterone to ∼940-fold for 2-butanone. Differential 12 C- and 13 C-DnsHz labeling was developed for quantifying metabolic differences in comparative samples where individual samples were separately labeled with 12 C-labeling and spiked with a 13 C-labeled pooled sample, followed by LC-MS analysis, peak pair picking, and peak intensity ratio measurement. In the replicate analysis of a 1:1 12 C-/ 13 C-labeled human urine mixture (n = 6), an average of 2030 ± 39 pairs per run were detected with 1737 pairs in common, indicating the possibility of detecting a large number of carbonyl metabolites as well as high reproducibility of peak pair detection. The average RSD of the peak pair ratios was 7.6%, and 95.6% of the pairs had a RSD value of less than 20%, demonstrating high precision for peak ratio measurement. In addition, the ratios of most peak pairs were close to the expected value of 1.0 (e.g., 95.5% of them had ratios of between 0.67 and 1.5), showing the high accuracy of the method. For metabolite identification, a library of DnsHz-labeled standards was constructed, including 78 carbonyl metabolites with each containing MS, retention time (RT), and MS/MS information. This library and an online search program for labeled carbonyl metabolite identification based on MS, RT, and MS/MS matches have been implemented in a freely available Website, www.mycompoundid.org . Using this library, out of the 1737 peak pairs detected in urine, 33 metabolites were positively identified. In addition, 1333 peak pairs could be matched to the metabolome databases with most of them belonging to the carbonyl metabolites. These results show that 12 C-/ 13 C-DnsHz labeling LC-MS is a useful tool for profiling the carbonyl submetabolome of complex samples with high coverage.

  8. Interest in Providing Multiple Sclerosis Care and Subspecializing in Multiple Sclerosis Among Neurology Residents

    PubMed Central

    Teixeira-Poit, Stephanie; Kane, Heather L.; Frost, A. Corey; Keating, Michael; Olmsted, Murrey

    2014-01-01

    Background: Although detailed knowledge regarding treatment options for multiple sclerosis (MS) patients is largely limited to neurologists, shortages in the neurologist workforce, including MS subspecialists, are predicted. Thus, MS patients may have difficulties in gaining access to appropriate care. No systematic evaluation has yet been performed of the number of neurology residents planning to pursue MS subspecialization. This study identifies factors affecting interest in providing MS patient care or MS subspecialization among current neurology residents. Methods: We randomly selected half of all Accreditation Council of Graduate Medical Education–certified neurology residency programs in the continental United States to receive the neurology resident survey. Completed surveys were received from 218 residents. Results: Residents were significantly more likely to have increased interest in MS care when they participated in MS research, were interested in teaching, and indicated that the “ability to improve patient outcomes and quality of life” was a positive factor influencing their desire to provide MS patient care. Residents who were interested in providing MS care, interested in teaching, and indicated that “research opportunities” was a positive factor for providing MS patient care were significantly more likely to express interest in MS subspecialization. Conclusions: Increasing opportunities to interact with MS patients, learn about MS care, and participate in MS research may increase interest in MS care and subspecialization among neurology residents. Opportunities to educate residents regarding MS patient care may affect residents’ attitudes. PMID:24688352

  9. Development and Optimisation of an HPLC-DAD-ESI-Q-ToF Method for the Determination of Phenolic Acids and Derivatives

    PubMed Central

    Restivo, Annalaura; Degano, Ilaria; Ribechini, Erika; Colombini, Maria Perla

    2014-01-01

    A method for the HPLC-MS/MS analysis of phenols, including phenolic acids and naphtoquinones, using an amide-embedded phase column was developed and compared to the literature methods based on classical C18 stationary phase columns. RP-Amide is a recently developed polar embedded stationary phase, whose wetting properties mean that up to 100% water can be used as an eluent. The increased retention and selectivity for polar compounds and the possibility of working in 100% water conditions make this column particularly interesting for the HPLC analysis of phenolic acids and derivatives. In this study, the chromatographic separation was optimised on an HPLC-DAD, and was used to separate 13 standard phenolic acids and derivatives. The method was validated on an HPLC-ESI-Q-ToF. The acquisition was performed in negative polarity and MS/MS target mode. Ionisation conditions and acquisition parameters for the Q-ToF detector were investigated by working on collision energies and fragmentor potentials. The performance of the method was fully evaluated on standards. Moreover, several raw materials containing phenols were analysed: walnut, gall, wine, malbec grape, French oak, red henna and propolis. Our method allowed us to characterize the phenolic composition in a wide range of matrices and to highlight possible matrix effects. PMID:24551158

  10. Application of Gas Chromatography-Tandem Mass Spectrometry (GC/MS/MS) for the Analysis of Deuterium Enrichment of Water

    PubMed Central

    Walker, Dillon K.; Thaden, John J.; Deutz, Nicolaas E.P.

    2015-01-01

    Incorporation of deuterium from deuterium oxide (2H2O) into biological components is a commonly used approach in metabolic studies. Determining the dilution of deuterium in the body water pool (BW) can be used to estimate body composition. We describe three sensitive GC-MS/MS methods to measure water enrichment in BW . Samples were reacted with NaOH and U-13C3-acetone in an autosampler vial to promote deuterium exchange with U-13C3-acetone hydrogens. Headspace injections were made of U-13C3-acetone-saturated air onto a 30m DB-1MS column in EI-mode. Subjects ingested 30ml 2H2O and plasma samples were collected. BW was determined by standard equation. DXA scans were performed to calculate body mass, body volume and bone mineral content. A 4 compartmental model was used to estimate body composition (fat and fat free mass). Full scan experiments generated a m/z 45 peak and to a lesser extent a m/z 61 peak. Product fragment ions further monitored included 45 and 46 using selected ion monitoring (SIM;Method1), the 61>45 and 62>46 transition using multiple reaction monitoring (MRM;Method2) and the Neutral Loss, 62>45, transition (Method3). MRM methods were optimized for collision energy (CE) and collision-induced dissociation (CID) argon gas pressure with 6eV CE and 1.5 mTorr CID gas being optimal. Method2 was used for finally determination of 2H2O enrichment of subjects due to lower natural background. We have developed a sensitive method to determine 2H2O enrichment in body water to enable measurement of FM and FFM. PMID:26169138

  11. Methods for simultaneous detection of the cyanotoxins BMAA, DABA, and anatoxin-a in environmental samples.

    PubMed

    Al-Sammak, Maitham Ahmed; Hoagland, Kyle D; Snow, Daniel D; Cassada, David

    2013-12-15

    Blue-green algae, also known as cyanobacteria, can produce several different groups of toxins in the environment including hepatotoxins (microcystins), neurotoxic non-protein amino acids β-methylamino-l-alanine (BMAA), and 2,4-diaminobutyric (DABA), as well as the bicyclic amine alkaloid anatoxin-a. Few studies have addressed the methods necessary for an accurate determination of cyanotoxins in environmental samples, and none have been published that can detect these cyanotoxins together in a single sample. Cyanotoxins occur in a wide range of environmental samples including water, fish, and aquatic plant samples. Using polymeric cation exchange solid phase extraction (SPE) coupled with liquid chromatography and fluorescence detection (HPLC/FD), and liquid chromatography ion trap tandem mass spectrometry (LC/MS/MS), these compounds can for the first time be simultaneously quantified in a variety of environmental sample types. The extraction method for biological samples can distinguish bound and free cyanotoxins. Detection limits for water ranged from 5 to 7 μg/L using HPLC/FD, while detection limits for and LC/MS were in the range of 0.8-3.2 μg/L. Copyright © 2013 Elsevier Ltd. All rights reserved.

  12. Multi-residue analysis of pesticides, plant hormones, veterinary drugs and mycotoxins using HILIC chromatography - MS/MS in various food matrices.

    PubMed

    Danezis, G P; Anagnostopoulos, C J; Liapis, K; Koupparis, M A

    2016-10-26

    One of the recent trends in Analytical Chemistry is the development of economic, quick and easy hyphenated methods to be used in a field that includes analytes of different classes and physicochemical properties. In this work a multi-residue method was developed for the simultaneous determination of 28 xenobiotics (polar and hydrophilic) using hydrophilic interaction liquid chromatography technique (HILIC) coupled with triple quadrupole mass spectrometry (LC-MS/MS) technology. The scope of the method includes plant growth regulators (chlormequat, daminozide, diquat, maleic hydrazide, mepiquat, paraquat), pesticides (cyromazine, the metabolite of the fungicide propineb PTU (propylenethiourea), amitrole), various multiclass antibiotics (tetracyclines, sulfonamides quinolones, kasugamycin and mycotoxins (aflatoxin B1, B2, fumonisin B1 and ochratoxin A). Isolation of the analytes from the matrix was achieved with a fast and effective technique. The validation of the multi-residue method was performed at the levels: 10 μg/kg and 100 μg/kg in the following representative substrates: fruits-vegetables (apples, apricots, lettuce and onions), cereals and pulses (flour and chickpeas), animal products (milk and meat) and cereal based baby foods. The method was validated taking into consideration EU guidelines and showed acceptable linearity (r ≥ 0.99), accuracy with recoveries between 70 and 120% and precision with RSD ≤ 20% for the majority of the analytes studied. For the analytes that presented accuracy and precision values outside the acceptable limits the method still is able to serve as a semi-quantitative method. The matrix effect, the limits of detection and quantification were also estimated and compared with the current EU MRLs (Maximum Residue Levels) and FAO/WHO MLs (Maximum Levels) or CXLs (Codex Maximum Residue Limits). The combined and expanded uncertainty of the method for each analyte per substrate, was also estimated. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Social aspects of multiple sclerosis for Iranian individuals.

    PubMed

    Abolhassani, Shahla; Yazdannik, Ahmadreza; Taleghani, Fariba; Zamani, Ahmadreza

    2015-01-01

    This study aimed to determine the social aspects of multiple sclerosis (MS) in the Iranian individuals. A qualitative case study approach was used for this study, which is a part of a larger qualitative study about health care delivery system of MS. Participants were selected on the basis of purposive sampling method. Semi-structured interviews regarding the social aspects of MS were conducted with 18 MS patients, 6 family members and 7 health care providers. Besides interviews with the participants, documents related to the aim of the study, including weblogs, MS magazines, special websites of individuals with MS and news agencies. Data analysis was performed using the qualitative content analysis technique. Data obtained has been categorised into five main categories, including confronting stigma symbols, the outcome of stigma, walling-in due to stigma, disturbance in normal life and concern about job. There are multiple social effects of MS on the afflicted individuals, which affect various dimensions of their life. Policy makers and health care providers must also consider these effects of MS on other dimensions of the individuals' life. Implications for Rehabilitation Multiple sclerosis (MS) is a disease which restricts social life for patients, in addition to physical impacts. Individuals with MS experienced stigma as well as problems with employment and marital life, due to improper information about MS in society. We recommend that health care workers offer proper information about MS to patients and their family members to minimise the social problems faced by them. We recommend that mass media offers proper information about MS to people in society to disseminate the correct picture of MS. We recommend that the rehabilitation team offers psychological support to patients and their families for their empowerment, to facilitate dealing with the impacts of the disease. We recommend that health care providers teach the family members about patient support and communication skills.

  14. Antidepressants detection and quantification in whole blood samples by GC-MS/MS, for forensic purposes.

    PubMed

    Truta, Liliana; Castro, André L; Tarelho, Sónia; Costa, Pedro; Sales, M Goreti F; Teixeira, Helena M

    2016-09-05

    Depression is among the most prevalent psychiatric disorders of our society, leading to an increase in antidepressant drug consumption that needs to be accurately determined in whole blood samples in Forensic Toxicology Laboratories. For this purpose, this work presents a new gas chromatography tandem mass spectrometry (GC-MS/MS) method targeting the simultaneous and rapid determination of 14 common Antidepressants in whole blood: 13 Antidepressants (amitriptyline, citalopram, clomipramine, dothiepin, fluoxetine, imipramine, mianserin, mirtazapine, nortryptiline, paroxetine, sertraline, trimipramine and venlafaxine) and 1 Metabolite (N-desmethylclomipramine). Solid-phase extraction was used prior to chromatographic separation. Chromatographic and MS/MS parameters were selected to improve sensitivity, peak resolution and unequivocal identification of the eluted analyte. The detection was performed on a triple quadrupole tandem MS in selected ion monitoring (SIM) mode in tandem, using electronic impact ionization. Clomipramine-D3 and trimipramine-D3 were used as deutered internal standards. The validation parameters included linearity, limits of detection, lower limit of quantification, selectivity/specificity, extraction efficiency, carry-over, precision and robustness, and followed internationally accepted guidelines. Limits of quantification and detection were lower than therapeutic and sub-therapeutic concentration ranges. Overall, the method offered good selectivity, robustness and quick response (<16min) for typical concentration ranges, both for therapeutic and lethal levels. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Different methods for volatile sampling in mammals

    PubMed Central

    Möller, Manfred; Marcillo, Andrea; Einspanier, Almuth; Weiß, Brigitte M.

    2017-01-01

    Previous studies showed that olfactory cues are important for mammalian communication. However, many specific compounds that convey information between conspecifics are still unknown. To understand mechanisms and functions of olfactory cues, olfactory signals such as volatile compounds emitted from individuals need to be assessed. Sampling of animals with and without scent glands was typically conducted using cotton swabs rubbed over the skin or fur and analysed by gas chromatography-mass spectrometry (GC-MS). However, this method has various drawbacks, including a high level of contaminations. Thus, we adapted two methods of volatile sampling from other research fields and compared them to sampling with cotton swabs. To do so we assessed the body odor of common marmosets (Callithrix jacchus) using cotton swabs, thermal desorption (TD) tubes and, alternatively, a mobile GC-MS device containing a thermal desorption trap. Overall, TD tubes comprised most compounds (N = 113), with half of those compounds being volatile (N = 52). The mobile GC-MS captured the fewest compounds (N = 35), of which all were volatile. Cotton swabs contained an intermediate number of compounds (N = 55), but very few volatiles (N = 10). Almost all compounds found with the mobile GC-MS were also captured with TD tubes (94%). Hence, we recommend TD tubes for state of the art sampling of body odor of mammals or other vertebrates, particularly for field studies, as they can be easily transported, stored and analysed with high performance instruments in the lab. Nevertheless, cotton swabs capture compounds which still may contribute to the body odor, e.g. after bacterial fermentation, while profiles from mobile GC-MS include only the most abundant volatiles of the body odor. PMID:28841690

  16. Simultaneous targeted analysis of trimethylamine-N-oxide, choline, betaine, and carnitine by high performance liquid chromatography tandem mass spectrometry.

    PubMed

    Liu, Jia; Zhao, Mingming; Zhou, Juntuo; Liu, Changjie; Zheng, Lemin; Yin, Yuxin

    2016-11-01

    Trimethylamine-N-oxide (TMAO) is a metabolite generated from choline, betaine and carnitine in a gut microbiota-dependent way. This molecule is associated with development of atherosclerosis and cardiovascular events. A sensitive liquid chromatographic electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS) has been developed and validated for the simultaneous determination of TMAO related molecules including TMAO, betaine, choline, and carnitine in mouse plasma. Analytes are extracted after protein precipitation by methanol and subjected to LC-ESI-MS/MS without preliminary derivatization. Separation of analytes was achieved on an amide column with acetonitrile-water as the mobile phase. This method has been fully validated in this study in terms of selectivity, linearity, sensitivity, precision, accuracy, and carryover effect, and the stability of the analyte under various conditions has been confirmed. This developed method has successfully been applied to plasma samples of our mouse model. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Determination of advanced glycation endproducts by LC-MS/MS in raw and roasted almonds (Prunus dulcis).

    PubMed

    Zhang, Gong; Huang, Guangwei; Xiao, Lu; Mitchell, Alyson E

    2011-11-23

    A sensitive and reliable LC-(ESI)MS/MS method was developed and validated for the simultaneous analysis of five common advanced glycation endproducts (AGEs) after enzymatic digestion in raw and roasted almonds. AGEs included carboxymethyl-lysine (CML), carboxyethyl-lysine (CEL), pyralline (Pyr), argpyrimidine (Arg-p), and pentosidine (Pento-s). This method allows accurate quantitation of free and AGE-protein adducts of target AGEs. Results indicate that CML and CEL are found in both raw and roasted almonds. Pyr was identified for the first time in roasted almonds and accounted for 64.4% of free plus bound measured AGEs. Arg-p and Pento-s were below the limit of detection in all almond samples tested. Free AGEs accounted for 1.3-26.8% of free plus bound measured AGEs, indicating that protein-bound forms predominate. The roasting process significantly increased CML, CEL, and Pyr formation, but no significant correlation was observed between these AGEs and roasting temperature.

  18. Determination of fluoroquinolones in chicken feces - a new liquid-liquid extraction method combined with LC-MS/MS.

    PubMed

    Janusch, Franziska; Scherz, Gesine; Mohring, Siegrun A I; Hamscher, Gerd

    2014-11-01

    The application of antibiotics including fluoroquinolones to farming animals is widespread and may lead to the development of antibiotic resistance and other environmental effects. To calculate environmental loads and for a proper risk assessment it is necessary to determine the antibiotic concentration in feces. Therefore, a new liquid-liquid extraction method combined with HPLC-MS/MS for the detection of marbofloxacin, ciprofloxacin, enrofloxacin and difloxacin in chicken feces was developed. Recoveries ranged from 51.0% to 83.5%. LOQs were between 0.10 and 1.09μg/kg. Feces of chickens treated with an enrofloxacin dosage of 10mg/kg bodyweight revealed maximum enrofloxacin and ciprofloxacin concentrations of 61.3 and 18.8mg/kg. Both antibiotics could be detected in feces up to two days after the last application in notable amounts (∼1mg/kg). Thus, feces of recently medicated chickens should not be used as a fertilizer without any further processing. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Chemical profiling of Qixue Shuangbu Tincture by ultra-performance liquid chromatography with electrospray ionization quadrupole-time-of-flight high-definition mass spectrometry (UPLC-QTOF/MS).

    PubMed

    Chen, Lin-Wei; Wang, Qin; Qin, Kun-Ming; Wang, Xiao-Li; Wang, Bin; Chen, Dan-Ni; Cai, Bao-Chang; Cai, Ting

    2016-02-01

    The present study was designed to develop and validate a sensitive and reliable ultra high performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry (UPLC-QTOF/MS) method to separate and identify the chemical constituents of Qixue Shuangbu Tincture (QXSBT), a classic traditional Chinese medicine (TCM) prescription. Under the optimized UPLC and QTOF/MS conditions, 56 components in QXSBT, including chalcones, triterpenoids, protopanaxatriol, flavones and flavanones were identified and tentatively characterized within a running time of 42 min. The components were identified by comparing the retention times, accurate mass, and mass spectrometric fragmentation characteristic ions, and matching empirical molecular formula with that of the published compounds. In conclusion, the established UPLC-QTOF/MS method was reliable for a rapid identification of complicated components in the TCM prescriptions. Copyright © 2016 China Pharmaceutical University. Published by Elsevier B.V. All rights reserved.

  20. Trace analysis of energetic materials via direct analyte-probed nanoextraction coupled to direct analysis in real time mass spectrometry.

    PubMed

    Clemons, Kristina; Dake, Jeffrey; Sisco, Edward; Verbeck, Guido F

    2013-09-10

    Direct analysis in real time mass spectrometry (DART-MS) has proven to be a useful forensic tool for the trace analysis of energetic materials. While other techniques for detecting trace amounts of explosives involve extraction, derivatization, solvent exchange, or sample clean-up, DART-MS requires none of these. Typical DART-MS analyses directly from a solid sample or from a swab have been quite successful; however, these methods may not always be an optimal sampling technique in a forensic setting. For example, if the sample were only located in an area which included a latent fingerprint of interest, direct DART-MS analysis or the use of a swab would almost certainly destroy the print. To avoid ruining such potentially invaluable evidence, another method has been developed which will leave the fingerprint virtually untouched. Direct analyte-probed nanoextraction coupled to nanospray ionization-mass spectrometry (DAPNe-NSI-MS) has demonstrated excellent sensitivity and repeatability in forensic analyses of trace amounts of illicit drugs from various types of surfaces. This technique employs a nanomanipulator in conjunction with bright-field microscopy to extract single particles from a surface of interest and has provided a limit of detection of 300 attograms for caffeine. Combining DAPNe with DART-MS provides another level of flexibility in forensic analysis, and has proven to be a sufficient detection method for trinitrotoluene (TNT), RDX, and 1-methylaminoanthraquinone (MAAQ). Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  1. UP-HILIC-MS/MS to Determine the Action Pattern of Penicillium sp. Dextranase.

    PubMed

    Yi, Lin; Sun, Xue; Du, Kenze; Ouyang, Yilan; Wu, Chengling; Xu, Naiyu; Linhardt, Robert J; Zhang, Zhenqing

    2015-07-01

    Investigation of the action pattern of enzymes acting on carbohydrates is challenging, as both the substrate and the digestion products are complex mixtures. Dextran and its enzyme-derived oligosaccharides are widely used for many industrial applications. In this work, a new method relying on ultra-performance hydrophilic interaction liquid chromatography quadrupole time-of-flight tandem mass spectrometry (UP-HILIC-Q/TOF-MS/MS) was developed to analyze a complex mixture of dextran oligosaccharide products to determine the action pattern of dextranase. No derivatization of oligosaccharides was required and the impact of the α- and β-configurations of the native oligosaccharides on the chromatographic separation was eliminated. The 1→6, 1→3, 1→4 backbone linkages and the branch linkages of these oligosaccharides were all distinguished from diagnostic ions in their MS/MS spectra, including fragments corresponding to (0,2)A, (0,3)A, (0,4)A, B-H2O, (2,5)A, and (3,5)A. The sequences of the oligosaccharide products were similarly established. Thus, the complex oligosaccharide mixtures in dextran digestion products were profiled and identified using this method. The more enzyme-resistant structures in dextran were established using much less sample, labor, time, and uncertainty than in previous studies. This method provides an efficient, sensitive, and straightforward way to monitor the entire process of digestion, establish the action pattern of the dextranase from Penicillium sp., and to support the proper industrial application of dextranase.

  2. 25OHD analogues and vacuum blood collection tubes dramatically affect the accuracy of automated immunoassays

    PubMed Central

    Yu, Songlin; Cheng, Xinqi; Fang, Huiling; Zhang, Ruiping; Han, Jianhua; Qin, Xuzhen; Cheng, Qian; Su, Wei; Hou, Li’an; Xia, Liangyu; Qiu, Ling

    2015-01-01

    Variations in vitamin D quantification methods are large, and influences of vitamin D analogues and blood collection methods have not been systematically examined. We evaluated the effects of vitamin D analogues 25OHD2 and 3-epi 25OHD3 and blood collection methods on vitamin D measurement, using five immunoassay systems and liquid chromatography-tandem mass spectrometry (LC-MS/MS). Serum samples (332) were selected from routine vitamin D assay requests, including samples with or without 25OHD2 or 3-epi 25OHD3, and analysed using various immunoassay systems. In samples with no 25OHD2 or 3-epi 25OHD3, all immunoassays correlated well with LC-MS/MS. However, the Siemens system produced a large positive mean bias of 12.5 ng/mL and a poor Kappa value when using tubes with clot activator and gel separator. When 25OHD2 or 3-epi 25OHD3 was present, correlations and clinical agreement decreased for all immunoassays. Serum 25OHD in VACUETTE tubes with gel and clot activator, as measured by the Siemens system, produced significantly higher values than did samples collected in VACUETTE tubes with no additives. Bias decreased and clinical agreement improved significantly when using tubes with no additives. In conclusion, most automated immunoassays showed acceptable correlation and agreement with LC-MS/MS; however, 25OHD analogues and blood collection tubes dramatically affected accuracy. PMID:26420221

  3. 25OHD analogues and vacuum blood collection tubes dramatically affect the accuracy of automated immunoassays.

    PubMed

    Yu, Songlin; Cheng, Xinqi; Fang, Huiling; Zhang, Ruiping; Han, Jianhua; Qin, Xuzhen; Cheng, Qian; Su, Wei; Hou, Li'an; Xia, Liangyu; Qiu, Ling

    2015-09-30

    Variations in vitamin D quantification methods are large, and influences of vitamin D analogues and blood collection methods have not been systematically examined. We evaluated the effects of vitamin D analogues 25OHD2 and 3-epi 25OHD3 and blood collection methods on vitamin D measurement, using five immunoassay systems and liquid chromatography-tandem mass spectrometry (LC-MS/MS). Serum samples (332) were selected from routine vitamin D assay requests, including samples with or without 25OHD2 or 3-epi 25OHD3, and analysed using various immunoassay systems. In samples with no 25OHD2 or 3-epi 25OHD3, all immunoassays correlated well with LC-MS/MS. However, the Siemens system produced a large positive mean bias of 12.5 ng/mL and a poor Kappa value when using tubes with clot activator and gel separator. When 25OHD2 or 3-epi 25OHD3 was present, correlations and clinical agreement decreased for all immunoassays. Serum 25OHD in VACUETTE tubes with gel and clot activator, as measured by the Siemens system, produced significantly higher values than did samples collected in VACUETTE tubes with no additives. Bias decreased and clinical agreement improved significantly when using tubes with no additives. In conclusion, most automated immunoassays showed acceptable correlation and agreement with LC-MS/MS; however, 25OHD analogues and blood collection tubes dramatically affected accuracy.

  4. Cloud-point extraction is compatible with liquid chromatography coupled to electrospray ionization mass spectrometry for the determination of antazoline in human plasma.

    PubMed

    Giebułtowicz, Joanna; Kojro, Grzegorz; Piotrowski, Roman; Kułakowski, Piotr; Wroczyński, Piotr

    2016-09-05

    Cloud-point extraction (CPE) is attracting increasing interest in a number of analytical fields, including bioanalysis, as it provides a simple, safe and environmentally-friendly sample preparation technique. However, there are only few reports on the application of this extraction technique in liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) analysis. In this study, CPE was used for the isolation of antazoline from human plasma. To date, only one method of antazoline isolation from plasma exists-liquid-liquid extraction (LLE). The aim of this study was to prove the compatibility of CPE and LC-ESI-MS/MS and the applicability of CPE to the determination of antazoline in spiked human plasma and clinical samples. Antazoline was isolated from human plasma using Triton X-114 as a surfactant. Xylometazoline was used as an internal standard. NaOH concentration, temperature and Triton X-114 concentration were optimized. The absolute matrix effect was carefully investigated. All validation experiments met international acceptance criteria and no significant relative matrix effect was observed. The compatibility of CPE and LC-ESI-MS/MS was confirmed using clinical plasma samples. The determination of antazoline concentration in human plasma in the range 10-2500ngmL(-1) by the CPE method led to results which are equivalent to those obtained by the widely used liquid-liquid extraction method. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. UP-HILIC-MS/MS to Determine the Action Pattern of Penicillium sp. Dextranase

    NASA Astrophysics Data System (ADS)

    Yi, Lin; Sun, Xue; Du, Kenze; Ouyang, Yilan; Wu, Chengling; Xu, Naiyu; Linhardt, Robert J.; Zhang, Zhenqing

    2015-07-01

    Investigation of the action pattern of enzymes acting on carbohydrates is challenging, as both the substrate and the digestion products are complex mixtures. Dextran and its enzyme-derived oligosaccharides are widely used for many industrial applications. In this work, a new method relying on ultra-performance hydrophilic interaction liquid chromatography quadrupole time-of-flight tandem mass spectrometry (UP-HILIC- Q/TOF-MS/MS) was developed to analyze a complex mixture of dextran oligosaccharide products to determine the action pattern of dextranase. No derivatization of oligosaccharides was required and the impact of the α- and β-configurations of the native oligosaccharides on the chromatographic separation was eliminated. The 1→6, 1→3, 1→4 backbone linkages and the branch linkages of these oligosaccharides were all distinguished from diagnostic ions in their MS/MS spectra, including fragments corresponding to 0,2A, 0,3A, 0,4A, B-H2O, 2,5A, and 3,5A. The sequences of the oligosaccharide products were similarly established. Thus, the complex oligosaccharide mixtures in dextran digestion products were profiled and identified using this method. The more enzyme-resistant structures in dextran were established using much less sample, labor, time, and uncertainty than in previous studies. This method provides an efficient, sensitive, and straightforward way to monitor the entire process of digestion, establish the action pattern of the dextranase from Penicillium sp., and to support the proper industrial application of dextranase.

  6. Comparative evaluation of liquid-liquid extraction, solid-phase extraction and solid-phase microextraction for the gas chromatography-mass spectrometry determination of multiclass priority organic contaminants in wastewater.

    PubMed

    Robles-Molina, José; Gilbert-López, Bienvenida; García-Reyes, Juan F; Molina-Díaz, Antonio

    2013-12-15

    The European Water Framework Directive (WFD) 2000/60/EC establishes guidelines to control the pollution of surface water by sorting out a list of priority substances that involves a significant risk to or via the aquatic systems. In this article, the analytical performance of three different sample preparation methodologies for the GC-MS/MS determination of multiclass organic contaminants-including priority comprounds from the WFD-in wastewater samples using gas chromatography-mass spectrometry was evaluated. The methodologies tested were: (a) liquid-liquid extraction (LLE) with n-hexane; (b) solid-phase extraction (SPE) with C18 cartridges and elution with ethyl acetate:dichloromethane (1:1 (v/v)), and (c) headspace solid-phase microextraction (HS-SPME) using two different fibers: polyacrylate and polydimethylsiloxane/carboxen/divinilbenzene. Identification and confirmation of the selected 57 compounds included in the study (comprising polycyclic aromatic hydrocarbons (PAHs), pesticides and other contaminants) were accomplished using gas chromatography tandem mass spectrometry (GC-MS/MS) with a triple quadrupole instrument operated in the multiple reaction monitoring (MRM) mode. Three MS/MS transitions were selected for unambiguous confirmation of the target chemicals. The different advantages and pitfalls of each method were discussed. In the case of both LLE and SPE procedures, the method was validated at two different concentration levels (15 and 150 ng L(-1)) obtaining recovery rates in the range 70-120% for most of the target compounds. In terms of analyte coverage, results with HS-SPME were not satisfactory, since 14 of the compounds tested were not properly recovered and the overall performance was worse than the other two methods tested. LLE, SPE and HS-SPME (using polyacrylate fiber) procedures also showed good linearity and precision. Using any of the three methodologies tested, limits of quantitation obtained for most of the detected compounds were in the low nanogram per liter range. © 2013 Elsevier B.V. All rights reserved.

  7. Improved mb-Ms Discrimination Using mb(P-coda) and MsU with Application to the Six North Korean Nuclear Tests

    NASA Astrophysics Data System (ADS)

    Napoli, V.; Yoo, S. H.; Russell, D. R.

    2017-12-01

    To improve discrimination of small explosions and earthquakes, we developed a new magnitude scale based on the standard Ms:mb discrimination method. In place of 20 second Ms measurements we developed a unified Rayleigh and Love wave magnitude scale (MsU) that is designed to maximize available information from single stations and then combine magnitude estimates into network averages. Additionally, in place of mb(P) measurements we developed an mb(P-Coda) magnitude scale as the properties of the coda make sparse network mb(P-Coda) more robust and less variable than network mb(P) estimates. A previous mb:MsU study conducted in 2013 in the Korean Peninsula shows that the use of MsU in place of standard 20 second Ms, leads to increased population separation and reduced scattering. The goals of a combined mb(P-coda):MsU scale are reducing scatter, ensuring applicability at small magnitudes with sparse networks, and improving the overall distribution for mb:Ms earthquake and explosion populations. To test this method we are calculating mb(P-coda)and MsU for a catalog earthquakes located in and near the Korean Peninsula, for the six North Korean nuclear tests (4.1 < mb < 6.3) and for the 3 aftershocks to date that occurred after the sixth test (2.6 < ML < 4.0). Compared to the previous 2013 study, we expect to see greater separation in the populations and less scattering with the inclusion of mb(P-coda) and with the implementation of additional filters for MsU to improve signal-to-noise levels; this includes S-transform filtering for polarization and off-azimuth signal reduction at regional distances. As we are expanding our database of mb(P-coda):MsU measurements in the Korean Peninsula to determine the earthquake and explosion distribution, this research will address the limitations and potential for discriminating small magnitude events using sparse networks.

  8. The ACCEND program: a combined BS and MS program in environmental engineering that includes co-operative work experience.

    PubMed

    Bishop, P L; Keener, T C; Kukreti, A R; Kowel, S T

    2004-01-01

    Environmental engineering education has rapidly expanded in recent years and new teaching methods are needed. Many professionals and educators believe that a MS degree in environmental engineering should be the minimum in order to practice the profession, along with practical training. This paper describes an innovative program being offered at the University of Cincinnati that combines an integrated BS in civil engineering and an MS in environmental engineering with extensive practical co-operative education (co-op) experience, all within a five-year period. The program includes distance learning opportunities during the co-op periods. The result is a well-trained graduate who will receive higher pay and more challenging career opportunities, and who will have developed professionalism and maturity beyond that from traditional engineering programs.

  9. Validation and use of three complementary analytical methods (LC-FLS, LC-MS/MS and ICP-MS) to evaluate the pharmacokinetics, biodistribution and stability of motexafin gadolinium in plasma and tissues.

    PubMed

    Miles, Dale R; Mesfin, Mimi; Mody, Tarak D; Stiles, Mark; Lee, Jean; Fiene, John; Denis, Bernie; Boswell, Garry W

    2006-05-01

    Liquid chromatography-fluorescence (LC-FLS), liquid chromatography-tandem mass spectrometry (LC-MS/MS) and inductively coupled plasma-mass spectrometry (ICP-MS) methods were developed and validated for the evaluation of motexafin gadolinium (MGd, Xcytrin) pharmacokinetics and biodistribution in plasma and tissues. The LC-FLS method exhibited the greatest sensitivity (0.0057 microg mL(-1)), and was used for pharmacokinetic, biodistribution, and protein binding studies with small sample sizes or low MGd concentrations. The LC-MS/MS method, which exhibited a short run time and excellent selectivity, was used for routine clinical plasma sample analysis. The ICP-MS method, which measured total Gd, was used in conjunction with LC methods to assess MGd stability in plasma. All three methods were validated using human plasma. The LC-FLS method was also validated using plasma, liver and kidneys from mice and rats. All three methods were shown to be accurate, precise and robust for each matrix validated. For three mice, the mean (standard deviation) concentration of MGd in plasma/tissues taken 5 hr after dosing with 23 mg kg(-1) MGd was determined by LC-FLS as follows: plasma (0.025+/-0.002 microg mL(-1)), liver (2.89+/-0.45 microg g(-1)), and kidney (6.09+/-1.05 microg g(-1)). Plasma samples from a subset of patients with brain metastases from extracranial tumors were analyzed using both LC-MS/MS and ICP-MS methods. For a representative patient, > or = 90% of the total Gd in plasma was accounted for as MGd over the first hour post dosing. By 24 hr post dosing, 63% of total Gd was accounted for as MGd, indicating some metabolism of MGd.

  10. Application of liquid chromatography-tandem mass spectrometry in the diagnosis and follow-up of maple syrup urine disease in a Chinese population.

    PubMed

    Lin, Na; Ye, Jun; Qiu, Wenjuan; Han, Lianshu; Zhang, Huiwen; Gu, Xuefan

    2013-01-01

    Maple syrup urine disease (MSUD) is an inherited disorder caused by a deficiency of the mitochondrial branched-chain keto acid dehydrogenase complex. We investigated whether liquid chromatography-tandem mass spectrometry (LC-MS/MS) is a more reliable and accurate method than MS/MS in the diagnosis and management of patients with MSUD in a Chinese population. A total of 370 dried blood spots (DBS) from healthy neonates, 44 DBS specimens from phenylketonuria neonates, and 38 DBS samples from 10 MSUD patients were retrospectively tested using the LC-MS/MS method. The results were compared with those obtained by the MS/MS method. The reference intervals of branched-chain amino acids (BCAAs) and alloiosleucine (Allo-Ile) were estimated for both sexes. In classic MSUD patients, Allo-Ile was markedly elevated (average of 136 μmol/L, which was significantly higher than the normal value, <5 μmol/L). The averages of BCAAs were also markedly elevated continually during the treatment. The application of the LC-MS/MS method in the measurement of Allo-Ile and BCAAs in DBS is more useful for diagnosing and managing classic MSUD than the MS/MS method.

  11. Development and Validation of an Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Method for Quantitative Analysis of Platinum in Plasma, Urine, and Tissues.

    PubMed

    Zhang, Ti; Cai, Shuang; Forrest, Wai Chee; Mohr, Eva; Yang, Qiuhong; Forrest, M Laird

    2016-09-01

    Cisplatin, a platinum chemotherapeutic, is one of the most commonly used chemotherapeutic agents for many solid tumors. In this work, we developed and validated an inductively coupled plasma mass spectrometry (ICP-MS) method for quantitative determination of platinum levels in rat urine, plasma, and tissue matrices including liver, brain, lungs, kidney, muscle, heart, spleen, bladder, and lymph nodes. The tissues were processed using a microwave accelerated reaction system (MARS) system prior to analysis on an Agilent 7500 ICP-MS. According to the Food and Drug Administration guidance for industry, bioanalytical validation parameters of the method, such as selectivity, accuracy, precision, recovery, and stability were evaluated in rat biological samples. Our data suggested that the method was selective for platinum without interferences caused by other presenting elements, and the lower limit of quantification was 0.5 ppb. The accuracy and precision of the method were within 15% variation and the recoveries of platinum for all tissue matrices examined were determined to be 85-115% of the theoretical values. The stability of the platinum-containing solutions, including calibration standards, stock solutions, and processed samples in rat biological matrices was investigated. Results indicated that the samples were stable after three cycles of freeze-thaw and for up to three months. © The Author(s) 2016.

  12. Development and Validation of an Inductively Coupled Plasma Mass Spectrometry (ICP-MS) Method for Quantitative Analysis of Platinum in Plasma, Urine, and Tissues

    PubMed Central

    Zhang, Ti; Cai, Shuang; Forrest, Wai Chee; Mohr, Eva; Yang, Qiuhong; Forrest, M. Laird

    2016-01-01

    Cisplatin, a platinum chemotherapeutic, is one of the most commonly used chemotherapeutic agents for many solid tumors. In this work, we developed and validated an inductively coupled plasma mass spectrometry (ICP-MS) method for quantitative determination of platinum levels in rat urine, plasma, and tissue matrices including liver, brain, lungs, kidney, muscle, heart, spleen, bladder, and lymph nodes. The tissues were processed using a microwave accelerated reaction system (MARS) system prior to analysis on an Agilent 7500 ICP-MS. According to the Food and Drug Administration guidance for industry, bioanalytical validation parameters of the method, such as selectivity, accuracy, precision, recovery, and stability were evaluated in rat biological samples. Our data suggested that the method was selective for platinum without interferences caused by other presenting elements, and the lower limit of quantification was 0.5 ppb. The accuracy and precision of the method were within 15% variation and the recoveries of platinum for all tissue matrices examined were determined to be 85–115% of the theoretical values. The stability of the platinum-containing solutions, including calibration standards, stock solutions, and processed samples in rat biological matrices was investigated. Results indicated that the samples were stable after three cycles of freeze–thaw and for up to three months. PMID:27527103

  13. A Fast and Robust UHPLC-MRM-MS Method to Characterize and Quantify Grape Skin Tannins after Chemical Depolymerization.

    PubMed

    Pinasseau, Lucie; Verbaere, Arnaud; Roques, Maryline; Meudec, Emmanuelle; Vallverdú-Queralt, Anna; Terrier, Nancy; Boulet, Jean-Claude; Cheynier, Véronique; Sommerer, Nicolas

    2016-10-21

    A rapid, sensitive, and selective analysis method using ultra high performance liquid chromatography coupled with triple-quadrupole mass spectrometry (UHPLC-QqQ-MS) has been developed for the characterization and quantification of grape skin flavan-3-ols after acid-catalysed depolymerization in the presence of phloroglucinol (phloroglucinolysis). The compound detection being based on specific MS transitions in Multiple Reaction Monitoring (MRM) mode, this fast gradient robust method allows analysis of constitutive units of grape skin proanthocyanidins, including some present in trace amounts, in a single injection, with a throughput of 6 samples per hour. This method was applied to a set of 214 grape skin samples from 107 different red and white grape cultivars grown under two conditions in the vineyard, irrigated or non-irrigated. The results of triplicate analyses confirmed the robustness of the method, which was thus proven to be suitable for high-throughput and large-scale metabolomics studies. Moreover, these preliminary results suggest that analysis of tannin composition is relevant to investigate the genetic bases of grape response to drought.

  14. A new dimethyl labeling-based SID-MRM-MS method and its application to three proteases involved in insulin maturation.

    PubMed

    Cheng, Dongwan; Zheng, Li; Hou, Junjie; Wang, Jifeng; Xue, Peng; Yang, Fuquan; Xu, Tao

    2015-01-01

    The absolute quantification of target proteins in proteomics involves stable isotope dilution coupled with multiple reactions monitoring mass spectrometry (SID-MRM-MS). The successful preparation of stable isotope-labeled internal standard peptides is an important prerequisite for the SID-MRM absolute quantification methods. Dimethyl labeling has been widely used in relative quantitative proteomics and it is fast, simple, reliable, cost-effective, and applicable to any protein sample, making it an ideal candidate method for the preparation of stable isotope-labeled internal standards. MRM mass spectrometry is of high sensitivity, specificity, and throughput characteristics and can quantify multiple proteins simultaneously, including low-abundance proteins in precious samples such as pancreatic islets. In this study, a new method for the absolute quantification of three proteases involved in insulin maturation, namely PC1/3, PC2 and CPE, was developed by coupling a stable isotope dimethyl labeling strategy for internal standard peptide preparation with SID-MRM-MS quantitative technology. This method offers a new and effective approach for deep understanding of the functional status of pancreatic β cells and pathogenesis in diabetes.

  15. Determination and removal of antibiotics in secondary effluent using a horizontal subsurface flow constructed wetland.

    PubMed

    Zhang, Chunhui; Ning, Ke; Zhang, Wenwen; Guo, Yuanjie; Chen, Jun; Liang, Chen

    2013-04-01

    Increased attention is currently being directed towards the potential negative effects of antibiotics and other PPCPs discharged into the aquatic environment via municipal WWTP secondary effluents. A number of analytical methods, such as high performance liquid chromatography technologies, including a high performance liquid chromatography-fluorescence method (HPLC-FLD), high performance liquid chromatography-UV detection method (HPLC-UV) and high performance liquid chromatography-mass spectrometry method (HPLC-MS), have been suggested as determination technologies for antibiotic residues in water. In this study, we implement a HPLC-MS/MS combined method to detect and analyze antibiotics in WWTP secondary effluent and apply a horizontal subsurface flow constructed wetland (CW) as an advanced wastewater treatment for removing antibiotics in the WWTP secondary effluent. The results show that there were 2 macrolides, 2 quinolones and 5 sulfas in WWTP secondary effluent among all the 22 antibiotics considered. After the CW advanced treatment, the concentration removal efficiencies and removal loads of 9 antibiotics were 53-100% and 0.004-0.7307 μg m(-2) per day, respectively.

  16. Multiple reaction monitoring assay based on conventional liquid chromatography and electrospray ionization for simultaneous monitoring of multiple cerebrospinal fluid biomarker candidates for Alzheimer's disease

    PubMed Central

    Choi1, Yong Seok; Lee, Kelvin H.

    2016-01-01

    Alzheimer's disease (AD) is the most common type of dementia, but early and accurate diagnosis remains challenging. Previously, a panel of cerebrospinal fluid (CSF) biomarker candidates distinguishing AD and non-AD CSF accurately (> 90%) was reported. Furthermore, a multiple reaction monitoring (MRM) assay based on nano liquid chromatography tandem mass spectrometry (nLC-MS/MS) was developed to help validate putative AD CSF biomarker candidates including proteins from the panel. Despite the good performance of the MRM assay, wide acceptance may be challenging because of limited availability of nLC-MS/MS systems laboratories. Thus, here, a new MRM assay based on conventional LC-MS/MS is presented. This method monitors 16 peptides representing 16 (of 23) biomarker candidates that belonged to the previous AD CSF panel. A 30-times more concentrated sample than the sample used for the previous study was loaded onto a high capacity trap column, and all 16 MRM transitions showed good linearity (average R2 = 0.966), intra-day reproducibility (average coefficient of variance (CV) = 4.78%), and inter-day reproducibility (average CV = 9.85%). The present method has several advantages such as a shorter analysis time, no possibility of target variability, and no need for an internal standard. PMID:26404792

  17. Microfluidic chip based nano liquid chromatography coupled to tandem mass spectrometry for the determination of abused drugs and metabolites in human hair.

    PubMed

    Zhu, Kevin Y; Leung, K Wing; Ting, Annie K L; Wong, Zack C F; Ng, Winki Y Y; Choi, Roy C Y; Dong, Tina T X; Wang, Tiejie; Lau, David T W; Tsim, Karl W K

    2012-03-01

    A microfluidic chip based nano-HPLC coupled to tandem mass spectrometry (nano-HPLC-Chip-MS/MS) has been developed for simultaneous measurement of abused drugs and metabolites: cocaine, benzoylecgonine, cocaethylene, norcocaine, morphine, codeine, 6-acetylmorphine, phencyclidine, amphetamine, methamphetamine, MDMA, MDA, MDEA, and methadone in the hair of drug abusers. The microfluidic chip was fabricated by laminating polyimide films and it integrated an enrichment column, an analytical column and a nanospray tip. Drugs were extracted from hairs by sonication, and the chromatographic separation was achieved in 15 min. The drug identification and quantification criteria were fulfilled by the triple quardropule tandem mass spectrometry. The linear regression analysis was calibrated by deuterated internal standards with all of the R(2) at least over 0.993. The limit of detection (LOD) and the limit of quantification (LOQ) were from 0.1 to 0.75 and 0.2 to 1.25 pg/mg, respectively. The validation parameters including selectivity, accuracy, precision, stability, and matrix effect were also evaluated here. In conclusion, the developed sample preparation method coupled with the nano-HPLC-Chip-MS/MS method was able to reveal the presence of drugs in hairs from the drug abusers, with the enhanced sensitivity, compared with the conventional HPLC-MS/MS.

  18. Computational and informatics strategies for identification of specific protein interaction partners in affinity purification mass spectrometry experiments

    PubMed Central

    Nesvizhskii, Alexey I.

    2013-01-01

    Analysis of protein interaction networks and protein complexes using affinity purification and mass spectrometry (AP/MS) is among most commonly used and successful applications of proteomics technologies. One of the foremost challenges of AP/MS data is a large number of false positive protein interactions present in unfiltered datasets. Here we review computational and informatics strategies for detecting specific protein interaction partners in AP/MS experiments, with a focus on incomplete (as opposite to genome-wide) interactome mapping studies. These strategies range from standard statistical approaches, to empirical scoring schemes optimized for a particular type of data, to advanced computational frameworks. The common denominator among these methods is the use of label-free quantitative information such as spectral counts or integrated peptide intensities that can be extracted from AP/MS data. We also discuss related issues such as combining multiple biological or technical replicates, and dealing with data generated using different tagging strategies. Computational approaches for benchmarking of scoring methods are discussed, and the need for generation of reference AP/MS datasets is highlighted. Finally, we discuss the possibility of more extended modeling of experimental AP/MS data, including integration with external information such as protein interaction predictions based on functional genomics data. PMID:22611043

  19. Multiple reaction monitoring assay based on conventional liquid chromatography and electrospray ionization for simultaneous monitoring of multiple cerebrospinal fluid biomarker candidates for Alzheimer's disease.

    PubMed

    Choi, Yong Seok; Lee, Kelvin H

    2016-03-01

    Alzheimer's disease (AD) is the most common type of dementia, but early and accurate diagnosis remains challenging. Previously, a panel of cerebrospinal fluid (CSF) biomarker candidates distinguishing AD and non-AD CSF accurately (>90 %) was reported. Furthermore, a multiple reaction monitoring (MRM) assay based on nano liquid chromatography tandem mass spectrometry (nLC-MS/MS) was developed to help validate putative AD CSF biomarker candidates including proteins from the panel. Despite the good performance of the MRM assay, wide acceptance may be challenging because of limited availability of nLC-MS/MS systems in laboratories. Thus, here, a new MRM assay based on conventional LC-MS/MS is presented. This method monitors 16 peptides representing 16 (of 23) biomarker candidates that belonged to the previous AD CSF panel. A 30-times more concentrated sample than the sample used for the previous study was loaded onto a high capacity trap column, and all 16 MRM transitions showed good linearity (average R(2) = 0.966), intra-day reproducibility (average coefficient of variance (CV) = 4.78 %), and inter-day reproducibility (average CV = 9.85 %). The present method has several advantages such as a shorter analysis time, no possibility of target variability, and no need for an internal standard.

  20. ROCS: a Reproducibility Index and Confidence Score for Interaction Proteomics Studies

    PubMed Central

    2012-01-01

    Background Affinity-Purification Mass-Spectrometry (AP-MS) provides a powerful means of identifying protein complexes and interactions. Several important challenges exist in interpreting the results of AP-MS experiments. First, the reproducibility of AP-MS experimental replicates can be low, due both to technical variability and the dynamic nature of protein interactions in the cell. Second, the identification of true protein-protein interactions in AP-MS experiments is subject to inaccuracy due to high false negative and false positive rates. Several experimental approaches can be used to mitigate these drawbacks, including the use of replicated and control experiments and relative quantification to sensitively distinguish true interacting proteins from false ones. Methods To address the issues of reproducibility and accuracy of protein-protein interactions, we introduce a two-step method, called ROCS, which makes use of Indicator Prey Proteins to select reproducible AP-MS experiments, and of Confidence Scores to select specific protein-protein interactions. The Indicator Prey Proteins account for measures of protein identifiability as well as protein reproducibility, effectively allowing removal of outlier experiments that contribute noise and affect downstream inferences. The filtered set of experiments is then used in the Protein-Protein Interaction (PPI) scoring step. Prey protein scoring is done by computing a Confidence Score, which accounts for the probability of occurrence of prey proteins in the bait experiments relative to the control experiment, where the significance cutoff parameter is estimated by simultaneously controlling false positives and false negatives against metrics of false discovery rate and biological coherence respectively. In summary, the ROCS method relies on automatic objective criterions for parameter estimation and error-controlled procedures. Results We illustrate the performance of our method by applying it to five previously published AP-MS experiments, each containing well characterized protein interactions, allowing for systematic benchmarking of ROCS. We show that our method may be used on its own to make accurate identification of specific, biologically relevant protein-protein interactions, or in combination with other AP-MS scoring methods to significantly improve inferences. Conclusions Our method addresses important issues encountered in AP-MS datasets, making ROCS a very promising tool for this purpose, either on its own or in conjunction with other methods. We anticipate that our methodology may be used more generally in proteomics studies and databases, where experimental reproducibility issues arise. The method is implemented in the R language, and is available as an R package called “ROCS”, freely available from the CRAN repository http://cran.r-project.org/. PMID:22682516

  1. Application of MALDI-TOF MS for the Identification of Food Borne Bacteria

    PubMed Central

    Pavlovic, Melanie; Huber, Ingrid; Konrad, Regina; Busch, Ulrich

    2013-01-01

    Matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) has recently emerged as a powerful tool for the routine identification of clinical isolates. MALDI-TOF MS based identification of bacteria has been shown to be more rapid, accurate and cost-efficient than conventional phenotypic techniques or molecular methods. Rapid and reliable identification of food-associated bacteria is also of crucial importance for food processing and product quality. This review is concerned with the applicability of MALDI-TOF MS for routine identification of foodborne bacteria taking the specific requirements of food microbiological laboratories and the food industry into account. The current state of knowledge including recent findings and new approaches are discussed. PMID:24358065

  2. Critical factors determining the quantification capability of matrix-assisted laser desorption/ionization– time-of-flight mass spectrometry

    PubMed Central

    Wang, Chia-Chen; Lai, Yin-Hung; Ou, Yu-Meng; Chang, Huan-Tsung; Wang, Yi-Sheng

    2016-01-01

    Quantitative analysis with mass spectrometry (MS) is important but challenging. Matrix-assisted laser desorption/ionization (MALDI) coupled with time-of-flight (TOF) MS offers superior sensitivity, resolution and speed, but such techniques have numerous disadvantages that hinder quantitative analyses. This review summarizes essential obstacles to analyte quantification with MALDI-TOF MS, including the complex ionization mechanism of MALDI, sensitive characteristics of the applied electric fields and the mass-dependent detection efficiency of ion detectors. General quantitative ionization and desorption interpretations of ion production are described. Important instrument parameters and available methods of MALDI-TOF MS used for quantitative analysis are also reviewed. This article is part of the themed issue ‘Quantitative mass spectrometry’. PMID:27644968

  3. A Randomized Controlled Trial of Cognitive Behavioral Therapy (CBT) for Adjusting to Multiple Sclerosis (The saMS Trial): Does CBT Work and for Whom Does It Work?

    ERIC Educational Resources Information Center

    Moss-Morris, Rona; Dennison, Laura; Landau, Sabine; Yardley, Lucy; Silber, Eli; Chalder, Trudie

    2013-01-01

    Objective: The aims were (a) to test the effectiveness of a nurse-led cognitive behavioral therapy (CBT) program to assist adjustment in the early stages of multiple sclerosis (MS) and (b) to determine moderators of treatment including baseline distress, social support (SS), and treatment preference. Method: Ninety-four ambulatory people with MS…

  4. Design of experiments as a tool for LC-MS/MS method development for the trace analysis of the potentially genotoxic 4-dimethylaminopyridine impurity in glucocorticoids.

    PubMed

    Székely, Gy; Henriques, B; Gil, M; Ramos, A; Alvarez, C

    2012-11-01

    The present study reports on a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method development strategy supported by design of experiments (DoE) for the trace analysis of 4-dimethylaminopyridine (DMAP). The conventional approaches for development of LC-MS/MS methods are usually via trial and error, varying intentionally the experimental factors which is time consuming and interactions between experimental factors are not considered. The LC factors chosen for the DoE study include flow (F), gradient (G) and injection volume (V(inj)) while cone voltage (E(con)) and collision energy (E(col)) were chosen as MS parameters. All of the five factors were studied simultaneously. The method was optimized with respect to four responses: separation of peaks (Sep), peak area (A(peak)), length of the analysis (T) and the signal to noise ratio (S/N). A quadratic model, namely central composite face (CCF) featuring 29 runs was used instead of a less powerful linear model since the increase in the number of injections was insignificant. In order to determine the robustness of the method a new set of DoE experiments was carried out applying robustness around the optimal conditions was evaluated applying a fractional factorial of resolution III with 11 runs, wherein additional factors - such as column temperature and quadrupole resolution - were considered. The method utilizes a Phenomenex Gemini NX C-18 HPLC analytical column with electrospray ionization and a triple quadrupole mass detector in multiple reaction monitoring (MRM) mode, resulting in short analyses with a 10min runtime. Drawbacks of derivatization, namely incomplete reaction and time consuming sample preparation, have been avoided and the change from SIM to MRM mode resulted in increased sensitivity and lower LOQ. The DoE method development strategy led to a method allowing the trace analysis of DMAP at 0.5 ng/ml absolute concentration which corresponds to a 0.1 ppm limit of quantification in 5mg/ml mometasone furoate glucocorticoid. The obtained method was validated in a linear range of 0.1-10 ppm and presented a %RSD of 0.02% for system precision. Regarding DMAP recovery in mometasone furoate, spiked samples produced %recoveries between 83 and 113% in the range of 0.1-2 ppm. Copyright © 2012 Elsevier B.V. All rights reserved.

  5. A Multifaceted Mass Spectrometric Method to Probe Feeding Related Neuropeptide Changes in Callinectes sapidus and Carcinus maenas

    NASA Astrophysics Data System (ADS)

    Zhang, Yuzhuo; DeLaney, Kellen; Hui, Limei; Wang, Junhua; Sturm, Robert M.; Li, Lingjun

    2018-02-01

    Food intake is regulated by various neuromodulators, including numerous neuropeptides. However, it remains elusive at the molecular and cellular level as to how these important chemicals regulate internal processes and which regions of the neuronal organs are responsible for regulating the behavior. Here we report a comparative neuropeptidomic analysis of the brain and pericardial organ (PO) in response to feeding in two well-studied crustacean physiology model organisms, Callinectes sapidus and Carcinus maenas, using mass spectrometry (MS) techniques. A multifaceted MS-based approach has been developed to obtain complementary information on the expression changes of a large array of neuropeptides in the brain and PO. The method employs stable isotope labeling of brain and PO extracts for relative MS quantitation, capillary electrophoresis (CE)-MS for fractionation and high-specificity analysis, and mass spectrometric imaging (MSI) for in-situ molecular mapping of peptides. A number of neuropeptides, including RFamides, B-type allatostatins (AST-B), RYamides, and orcokinins exhibit significant changes in abundance after feeding in this investigation. Peptides from the AST-B family found in PO tissue were shown to have both altered expression and localization changes after feeding, indicating that they may be a class of vital neuropeptide regulators involved in feeding behavior. [Figure not available: see fulltext.

  6. A Multifaceted Mass Spectrometric Method to Probe Feeding Related Neuropeptide Changes in Callinectes sapidus and Carcinus maenas

    NASA Astrophysics Data System (ADS)

    Zhang, Yuzhuo; DeLaney, Kellen; Hui, Limei; Wang, Junhua; Sturm, Robert M.; Li, Lingjun

    2018-05-01

    Food intake is regulated by various neuromodulators, including numerous neuropeptides. However, it remains elusive at the molecular and cellular level as to how these important chemicals regulate internal processes and which regions of the neuronal organs are responsible for regulating the behavior. Here we report a comparative neuropeptidomic analysis of the brain and pericardial organ (PO) in response to feeding in two well-studied crustacean physiology model organisms, Callinectes sapidus and Carcinus maenas, using mass spectrometry (MS) techniques. A multifaceted MS-based approach has been developed to obtain complementary information on the expression changes of a large array of neuropeptides in the brain and PO. The method employs stable isotope labeling of brain and PO extracts for relative MS quantitation, capillary electrophoresis (CE)-MS for fractionation and high-specificity analysis, and mass spectrometric imaging (MSI) for in-situ molecular mapping of peptides. A number of neuropeptides, including RFamides, B-type allatostatins (AST-B), RYamides, and orcokinins exhibit significant changes in abundance after feeding in this investigation. Peptides from the AST-B family found in PO tissue were shown to have both altered expression and localization changes after feeding, indicating that they may be a class of vital neuropeptide regulators involved in feeding behavior. [Figure not available: see fulltext.

  7. A Multifaceted Mass Spectrometric Method to Probe Feeding Related Neuropeptide Changes in Callinectes sapidus and Carcinus maenas.

    PubMed

    Zhang, Yuzhuo; DeLaney, Kellen; Hui, Limei; Wang, Junhua; Sturm, Robert M; Li, Lingjun

    2018-05-01

    Food intake is regulated by various neuromodulators, including numerous neuropeptides. However, it remains elusive at the molecular and cellular level as to how these important chemicals regulate internal processes and which regions of the neuronal organs are responsible for regulating the behavior. Here we report a comparative neuropeptidomic analysis of the brain and pericardial organ (PO) in response to feeding in two well-studied crustacean physiology model organisms, Callinectes sapidus and Carcinus maenas, using mass spectrometry (MS) techniques. A multifaceted MS-based approach has been developed to obtain complementary information on the expression changes of a large array of neuropeptides in the brain and PO. The method employs stable isotope labeling of brain and PO extracts for relative MS quantitation, capillary electrophoresis (CE)-MS for fractionation and high-specificity analysis, and mass spectrometric imaging (MSI) for in-situ molecular mapping of peptides. A number of neuropeptides, including RFamides, B-type allatostatins (AST-B), RYamides, and orcokinins exhibit significant changes in abundance after feeding in this investigation. Peptides from the AST-B family found in PO tissue were shown to have both altered expression and localization changes after feeding, indicating that they may be a class of vital neuropeptide regulators involved in feeding behavior. Graphical Abstract ᅟ.

  8. Quantitative PCR measurement of tRNA 2-methylthio modification for assessing type 2 diabetes risk.

    PubMed

    Xie, Peiyu; Wei, Fan-Yan; Hirata, Shoji; Kaitsuka, Taku; Suzuki, Tsutomu; Suzuki, Takeo; Tomizawa, Kazuhito

    2013-11-01

    Genetic variants in the human CDKAL1 (CDK5 regulatory subunit associated protein 1-like 1) gene have been associated with reduced insulin secretion and type 2 diabetes (T2D). CDKAL1 is a methylthiotransferase that catalyzes 2-methylthio (ms(2)) modification of the adenine at position 37 (A37) of cytoplasmic tRNA(Lys)(UUU). We investigated the ms(2)-modification level of tRNA(Lys)(UUU) as a direct readout of CDKAL1 enzyme activity in human samples. We developed a quantitative PCR (qPCR)-based method to measure ms(2) modification. tRNA(Lys)(UUU) was reverse-transcribed with 2 unique primers: Reverse primer r1 was designed to anneal to the middle of this tRNA, including the nucleotide at A37, and reverse primer r2 was designed to anneal to the region downstream (3') of A37. Subsequent qPCR was performed to detect the corresponding transcribed cDNAs. The efficiency of reverse transcription of tRNA(Lys)(UUU) was ms(2)-modification dependent. The relative difference in threshold cycle number obtained with the r1 or r2 primer yielded the ms(2)-modification level in tRNA(Lys)(UUU) precisely as predicted by an original mathematical model. The method was capable of measuring ms(2)-modification levels in tRNA(Lys)(UUU) in total RNA isolated from human peripheral blood samples, revealing that the ms(2)-modification rate in tRNA(Lys)(UUU) was decreased in individuals carrying the CDKAL1 genotype associated with T2D. In addition, the ms(2)-modification level was correlated with insulin secretion. The results point to the critical role of ms(2) modification in T2D and to a potential clinical use of a simple and high-throughput method for assessing T2D risk.

  9. Breaking through the uncertainty ceiling in LA-ICP-MS U-Pb geochronology

    NASA Astrophysics Data System (ADS)

    Horstwood, M.

    2016-12-01

    Sources of systematic uncertainty associated with session-to-session bias are the dominant contributor to the 2% (2s) uncertainty ceiling that currently limits the accuracy of LA-ICP-MS U-Pb geochronology. Sources include differential downhole fractionation (LIEF), `matrix effects' and ablation volume differences, which result in irreproducibility of the same reference material across sessions. Current mitigation methods include correcting for LIEF mathematically, using matrix-matched reference materials, annealing material to reduce or eliminate radiation damage effects and tuning for robust plasma conditions. Reducing the depth and volume of ablation can also mitigate these problems and should contribute to the reduction of the uncertainty ceiling. Reducing analysed volume leads to increased detection efficiency, reduced matrix-effects, eliminates LIEF, obviates ablation rate differences and reduces the likelihood of intercepting complex growth zones with depth, thereby apparently improving material homogeneity. High detection efficiencies (% level) and low sampling volumes (20um box, 1-2um deep) can now be achieved using MC-ICP-MS such that low volume ablations should be considered part of the toolbox of methods targeted at improving the reproducibility of LA-ICP-MS U-Pb geochronology. In combination with other strategies these improvements should be feasible on any ICP platform. However, reducing the volume of analysis reduces detected counts and requires a change of analytical approach in order to mitigate this. Appropriate strategies may include the use of high efficiency cell and torch technologies and the optimisation of acquisition protocols and data handling techniques such as condensing signal peaks, using log ratios and total signal integration. The tools required to break the 2% (2s) uncertainty ceiling in LA-ICP-MS U-Pb geochronology are likely now known but require a coherent strategy and change of approach to combine their implementation and realise this goal. This study will highlight these changes and efforts towards reducing the uncertainty contribution for LA-ICP-MS U-Pb geochronology.

  10. Multiple Reaction Monitoring for Direct Quantitation of Intact Proteins Using a Triple Quadrupole Mass Spectrometer

    NASA Astrophysics Data System (ADS)

    Wang, Evelyn H.; Combe, Peter C.; Schug, Kevin A.

    2016-05-01

    Methods that can efficiently and effectively quantify proteins are needed to support increasing demand in many bioanalytical fields. Triple quadrupole mass spectrometry (QQQ-MS) is sensitive and specific, and it is routinely used to quantify small molecules. However, low resolution fragmentation-dependent MS detection can pose inherent difficulties for intact proteins. In this research, we investigated variables that affect protein and fragment ion signals to enable protein quantitation using QQQ-MS. Collision induced dissociation gas pressure and collision energy were found to be the most crucial variables for optimization. Multiple reaction monitoring (MRM) transitions for seven standard proteins, including lysozyme, ubiquitin, cytochrome c from both equine and bovine, lactalbumin, myoglobin, and prostate-specific antigen (PSA) were determined. Assuming the eventual goal of applying such methodology is to analyze protein in biological fluids, a liquid chromatography method was developed. Calibration curves of six standard proteins (excluding PSA) were obtained to show the feasibility of intact protein quantification using QQQ-MS. Linearity (2-3 orders), limits of detection (0.5-50 μg/mL), accuracy (<5% error), and precision (1%-12% CV) were determined for each model protein. Sensitivities for different proteins varied considerably. Biological fluids, including human urine, equine plasma, and bovine plasma were used to demonstrate the specificity of the approach. The purpose of this model study was to identify, study, and demonstrate the advantages and challenges for QQQ-MS-based intact protein quantitation, a largely underutilized approach to date.

  11. Methods for the analysis of organophosphorus flame retardants-Comparison of GC-EI-MS, GC-NCI-MS, LC-ESI-MS/MS, and LC-APCI-MS/MS.

    PubMed

    Tokumura, Masahiro; Miyake, Yuichi; Wang, Qi; Nakayama, Hayato; Amagai, Takashi; Ogo, Sayaka; Kume, Kazunari; Kobayashi, Takeshi; Takasu, Shinji; Ogawa, Kumiko

    2018-04-16

    Organophosphorus flame retardants (PFRs) are extensively used as alternatives to banned polybrominated diphenyl ethers (PBDEs) and hexabromocyclododecane (HBCD). In this study, we analyzed 14 PFRs by means of four mass-spectrometry-based methods: gas chromatography combined with electron-impact mass spectrometry (GC-EI-MS) or negative-chemical-ionization mass spectrometry (GC-NCI-MS) and liquid chromatography combined with tandem mass spectrometry using electrospray ionization (LC-ESI-MS/MS) or atmospheric pressure chemical ionization (LC-APCI-MS/MS). The limits of quantification (LOQs) for LC-ESI-MS/MS and LC-APCI-MS/MS (0.81-970 pg) were 1-2 orders of magnitude lower than the LOQs for GC-EI-MS and GC-NCI-MS (2.3-3900 pg). LC-APCI-MS/MS showed the lowest LOQs (mean = 41 pg; median = 3.4 pg) for all but two of the PFRs targeted in this study. For LC-APCI-MS/MS, the lowest LOQ was observed for tributyl phosphate (TBP) (0.81 pg), and the highest was observed for tris(butoxyethyl) phosphate (TBOEP) (36 pg). The results of this study indicate that LC-APCI-MS/MS is the optimum analytical method for the target PFRs, at least in terms of LOQ.

  12. Qualitative screening of veterinary anti-microbial agents in tissues, milk, and eggs of food-producing animals using liquid chromatography coupled with tandem mass spectrometry.

    PubMed

    Chen, Dongmei; Yu, Jie; Tao, Yanfei; Pan, Yuanhu; Xie, Shuyu; Huang, Lingli; Peng, Dapeng; Wang, Xu; Wang, Yulian; Liu, Zhenli; Yuan, Zonghui

    2016-04-01

    A method for the analysis of 120 drugs in animal derived food was developed using liquid chromatography-tandem mass spectrometry (LC-MS/MS). These analytes belong to 12 families of veterinary anti-microbial agents (quinolones, macrolides, β-lactams, nitroimidazoles, sulfonamides, lincomycines, chloramphenicols, quinoxalines, tetracyclines, polypeptides, and antibacterial synergists) as well as other compounds not assigned to a particular drug family. The animal derived food samples include muscle and liver of swine, bovine, sheep, and chicken, as well as hen eggs and dairy milk. The sample preparation included ultrasound-assisted extraction (UAE) with acetonitrile-water and a final clean-up with auto solid-phase extraction (SPE) on HLB cartridges. The detection and quantification of 120 anti-microbial agents was performed using LC-MS/MS in positive and negative ion mode. The chromatographic separation was performed on a C18 column using acetonitrile and 0.1% formic acid as the mobile phase. The limit of detection (LOD) and limit of quantification (LOQ) of all drugs in food-producing animals were 0.5-3.0μg/kg and 1.5-10.0μg/kg, respectively. The developed method was successfully utilized to monitor real samples, which demonstrated that it is a simple, fast, and robust method, and could be used as a regulatory to screen for the presence of residues from veterinary anti-microbial drugs in animal-derived foods. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. High Resolution Laser Mass Spectrometry Bioimaging

    PubMed Central

    Murray, Kermit K.; Seneviratne, Chinthaka A.; Ghorai, Suman

    2016-01-01

    MSI (MSI) was introduced more than five decades ago with secondary ion mass spectrometry (SIMS) and a decade later with laser desorption/ionization (LDI) mass spectrometry (MS). Large biomolecule imaging by matrix-assisted laser desorption/ionization (MALDI) was developed in the 1990s and ambient laser MS a decade ago. Although SIMS has been capable of imaging with a moderate mass range at sub-micrometer lateral resolution from its inception, laser MS requires additional effort to achieve a lateral resolution of 10 μm or below which is required to image at the size scale of single mammalian cells. This review covers untargeted large biomolecule MSI using lasers for desorption/ionization or laser desorption and post-ionization. These methods include laser microprobe (LDI) MSI, MALDI MSI, laser ambient and atmospheric pressure MSI, and near-field laser ablation MS. Novel approaches to improving lateral resolution are discussed, including oversampling, beam shaping, transmission geometry, reflective and through-hole objectives, microscope mode, and near-field optics. PMID:26972785

  14. High resolution laser mass spectrometry bioimaging.

    PubMed

    Murray, Kermit K; Seneviratne, Chinthaka A; Ghorai, Suman

    2016-07-15

    Mass spectrometry imaging (MSI) was introduced more than five decades ago with secondary ion mass spectrometry (SIMS) and a decade later with laser desorption/ionization (LDI) mass spectrometry (MS). Large biomolecule imaging by matrix-assisted laser desorption/ionization (MALDI) was developed in the 1990s and ambient laser MS a decade ago. Although SIMS has been capable of imaging with a moderate mass range at sub-micrometer lateral resolution from its inception, laser MS requires additional effort to achieve a lateral resolution of 10μm or below which is required to image at the size scale of single mammalian cells. This review covers untargeted large biomolecule MSI using lasers for desorption/ionization or laser desorption and post-ionization. These methods include laser microprobe (LDI) MSI, MALDI MSI, laser ambient and atmospheric pressure MSI, and near-field laser ablation MS. Novel approaches to improving lateral resolution are discussed, including oversampling, beam shaping, transmission geometry, reflective and through-hole objectives, microscope mode, and near-field optics. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Meditation as an Adjunct to the Management of Multiple Sclerosis

    PubMed Central

    Levin, Adam B.; Hadgkiss, Emily J.; Weiland, Tracey J.; Jelinek, George A.

    2014-01-01

    Background. Multiple sclerosis (MS) disease course is known to be adversely affected by several factors including stress. A proposed mechanism for decreasing stress and therefore decreasing MS morbidity and improving quality of life is meditation. This review aims to critically analyse the current literature regarding meditation and MS. Methods. Four major databases were used to search for English language papers published before March 2014 with the terms MS, multiple sclerosis, meditation, and mindfulness. Results. 12 pieces of primary literature fitting the selection criteria were selected: two were randomised controlled studies, four were cohort studies, and six were surveys. The current literature varies in quality; however common positive effects of meditation include improved quality of life (QOL) and improved coping skills. Conclusion. All studies suggest possible benefit to the use of meditation as an adjunct to the management of multiple sclerosis. Additional rigorous clinical trials are required to validate the existing findings and determine if meditation has an impact on disease course over time. PMID:25105026

  16. Single hair analysis of small molecules using MALDI-triple quadrupole MS imaging and LC-MS/MS: investigations on opportunities and pitfalls.

    PubMed

    Poetzsch, Michael; Steuer, Andrea E; Roemmelt, Andreas T; Baumgartner, Markus R; Kraemer, Thomas

    2014-12-02

    Single hair analysis normally requires extensive sample preparation microscale protocols including time-consuming steps like segmentation and extraction. Matrix assisted laser desorption and ionization mass spectrometric imaging (MALDI-MSI) was shown to be an alternative tool in single hair analysis, but still, questions remain. Therefore, an investigation of MALDI-MSI in single hair analysis concerning the extraction process, usage of internal standard (IS), and influences on the ionization processes were systematically investigated to enable the reliable application to hair analysis. Furthermore, single dose detection, quantitative correlation to a single hair, and hair strand LC-MS/MS results were performed, and the performance was compared to LC-MS/MS single hair monitoring. The MALDI process was shown to be independent from natural hair color and not influenced by the presence of melanin. Ionization was shown to be reproducible along and in between different hair samples. MALDI image intensities in single hair and hair snippets showed good semiquantitative correlation to zolpidem hair concentrations obtained from validated routine LC-MS/MS methods. MALDI-MSI is superior to LC-MS/MS analysis when a fast, easy, and cheap sample preparation is necessary, whereas LC-MS/MS showed higher sensitivity with the ability of single dose detection for zolpidem. MALDI-MSI and LC-MS/MS segmental single hair analysis showed good correlation, and both are suitable for consumption monitoring of drugs of abuse with a high time resolution.

  17. Affect and Sexual Behavior in Adolescents: A Review of the Literature and Comparison of Momentary Sampling With Diary and Retrospective Self-Report Methods of Measurement

    PubMed Central

    Shrier, Lydia A.; Shih, Mei-Chiung; Beardslee, William R.

    2006-01-01

    Objective Assessment of mental health is important in understanding sexual risk behavior in adolescents, yet few studies have examined how affect is directly related to sexual behavior. Momentary sampling (MS) methods permit real-time assessment of affect in relation to specific events and embed the collected data in the context of the respondent’s moment-to-moment life. The objectives of this study were to review the literature on affect and sexual behavior and to compare the feasibility and acceptability of MS with diaries and retrospective self-report as a means of collecting temporally relevant data on affect and sexual behavior in adolescents. Methods Sexually active, nondepressed adolescent outpatients who were aged 15 to 18 years were randomly assigned to a schedule of the 3 methods of data collection for 2 weeks each. All participants completed a retrospective self-report by interview at the end of each 2-week period. In the diary arm, participants completed twice-daily paper-and-pencil diary cards, which were returned by mail. In the MS arm, participants used 2-way pagers to respond to several random pages per day. Primary outcomes included rates of completion (diaries vs MS reports) and the participants’ tolerance of and preferences for the methods. A secondary outcome was the agreement in means for positive and negative affect and in report of days on which substance use and sexual activity occurred. Associations of affect with contextual factors and with sexual activity were also explored in the MS arm. Results Ten youths completed 30 of 30 retrospective self-reports (100%, 3 per participant, by design), 254 of 280 diaries (91%; mean: 25.4 per participant), and 442 of 600 MS reports (74%; mean: 44.2 per participant). Most participants preferred the MS method to the diaries or retrospective self-report. Affect scores and reports of sexual activity and substance use were correlated among the methods. Measured with MS, affect was found to differ by location, companionship, and thoughts when paged; notably, positive affect was highest when participants reported thoughts about sex. There was no difference in affect before versus after coitus. Conclusions The results of this study suggest that MS in adolescents is feasible and preferred and provides contextual, temporally relevant, event-level data on affect and sexual activity that are not readily measured with traditional methods. Future research using MS methods will be important in increasing our understanding of the link between affect and sexual behavior and inform the development of improved risk reduction interventions for adolescents. Pediatrics 2005;115:e573–e581. URL: www.pediatrics.org/cgi/doi/10.1542/peds.2004-2073; affect, sexual behavior, substance use, momentary sampling, diary, retrospective self-report. PMID:15867022

  18. Targeted Proteomic Quantification on Quadrupole-Orbitrap Mass Spectrometer*

    PubMed Central

    Gallien, Sebastien; Duriez, Elodie; Crone, Catharina; Kellmann, Markus; Moehring, Thomas; Domon, Bruno

    2012-01-01

    There is an immediate need for improved methods to systematically and precisely quantify large sets of peptides in complex biological samples. To date protein quantification in biological samples has been routinely performed on triple quadrupole instruments operated in selected reaction monitoring mode (SRM), and two major challenges remain. Firstly, the number of peptides to be included in one survey experiment needs to be increased to routinely reach several hundreds, and secondly, the degree of selectivity should be improved so as to reliably discriminate the targeted analytes from background interferences. High resolution and accurate mass (HR/AM) analysis on the recently developed Q-Exactive mass spectrometer can potentially address these issues. This instrument presents a unique configuration: it is constituted of an orbitrap mass analyzer equipped with a quadrupole mass filter as the front-end for precursor ion mass selection. This configuration enables new quantitative methods based on HR/AM measurements, including targeted analysis in MS mode (single ion monitoring) and in MS/MS mode (parallel reaction monitoring). The ability of the quadrupole to select a restricted m/z range allows one to overcome the dynamic range limitations associated with trapping devices, and the MS/MS mode provides an additional stage of selectivity. When applied to targeted protein quantification in urine samples and benchmarked with the reference SRM technique, the quadrupole-orbitrap instrument exhibits similar or better performance in terms of selectivity, dynamic range, and sensitivity. This high performance is further enhanced by leveraging the multiplexing capability of the instrument to design novel acquisition methods and apply them to large targeted proteomic studies for the first time, as demonstrated on 770 tryptic yeast peptides analyzed in one 60-min experiment. The increased quality of quadrupole-orbitrap data has the potential to improve existing protein quantification methods in complex samples and address the pressing demand of systems biology or biomarker evaluation studies. PMID:22962056

  19. Small-scale purification of butyrylcholinesterase from human plasma and implementation of a μLC-UV/ESI MS/MS method to detect its organophosphorus adducts.

    PubMed

    John, Harald; Breyer, Felicitas; Schmidt, Christian; Mizaikoff, Boris; Worek, Franz; Thiermann, Horst

    2015-10-01

    Human butyrylcholinesterase (hBChE) is a serine hydrolase (EC 3.1.1.8) present in all mammalian tissues and the bloodstream. Similar to acetylcholinesterase, the enzyme reacts with organophosphorus compounds (OP) like nerve agents or pesticides that cause enzyme inhibition (BChE adducts). These adducts represent valuable biomarkers for analytical verification of OP exposure. For establishment of these mass spectrometry based methods sufficient amounts of hBChE in high purity are required. Unfortunately, commercial lots are of inappropriate purity thus favouring in-house isolation. Therefore, we developed a small scale procedure to isolate hBChE from citrate plasma. After precipitation by polyethylene glycol (8% w/v and 20% w/v PEG 6000) hBChE was purified from plasma by four consecutive chromatographic steps including anion exchange, affinity extraction and size exclusion. Protein elution was monitored on-line by UV-absorbance (280 nm) followed by continuous fractionation for off-line analysis of (1) hBChE enzyme activity by Ellman assay, (2) protein purity by gel electrophoresis, and (3) protein identity by matrix-assisted laser desorption/ionization mass spectrometry (MALDI MS). Numerous major impurities separated from hBChE were identified. The purified material was used for in vitro incubation with diverse OP to establish a μ-liquid chromatography-ultra violet detection/electrospray ionization tandem-mass spectrometric method (μLC-UV/ESI MS/MS) for detection of hBChE adducts suitable for verification analysis. Analytical data for diverse OP pesticides including deuterated analogues as well as G- and V-type nerve agents and their precursor are summarized. This method was successfully applied to plasma samples provided by the Organisation for the Prohibition of Chemical Weapons (OPCW) for the 4th Biomedical Exercise. Copyright © 2015 John Wiley & Sons, Ltd.

  20. A candidate reference method using ICP-MS for sweat chloride quantification.

    PubMed

    Collie, Jake T; Massie, R John; Jones, Oliver A H; Morrison, Paul D; Greaves, Ronda F

    2016-04-01

    The aim of the study was to develop a method for sweat chloride (Cl) quantification using Inductively Coupled Plasma Mass Spectrometry (ICP-MS) to present to the Joint Committee for Traceability in Laboratory Medicine (JCTLM) as a candidate reference method for the diagnosis of cystic fibrosis (CF). Calibration standards were prepared from sodium chloride (NaCl) to cover the expected range of sweat Cl values. Germanium (Ge) and scandium (Sc) were selected as on-line (instrument based) internal standards (IS) and gallium (Ga) as the off-line (sample based) IS. The method was validated through linearity, accuracy and imprecision studies as well as enrolment into the Royal College of Pathologists of Australasia Quality Assurance Program (RCPAQAP) for sweat electrolyte testing. Two variations of the ICP-MS method were developed, an on-line and off-line IS, and compared. Linearity was determined up to 225 mmol/L with a limit of quantitation of 7.4 mmol/L. The off-line IS demonstrated increased accuracy through the RCPAQAP performance assessment (CV of 1.9%, bias of 1.5 mmol/L) in comparison to the on-line IS (CV of 8.0%, bias of 3.8 mmol/L). Paired t-tests confirmed no significant differences between sample means of the two IS methods (p=0.53) or from each method against the RCPAQAP target values (p=0.08 and p=0.29). Both on and off-line IS methods generated highly reproducible results and excellent linear comparison to the RCPAQAP target results. ICP-MS is a highly accurate method with a low limit of quantitation for sweat Cl analysis and should be recognised as a candidate reference method for the monitoring and diagnosis of CF. Laboratories that currently practice sweat Cl analysis using ICP-MS should include an off-line IS to help negate any pre-analytical errors.

  1. [Determination of 25 quinolones in cosmetics by liquid chromatography-tandem mass spectrometry].

    PubMed

    Lin, Li; Zhang, Yi; Tu, Xiaoke; Xie, Liqi; Yue, Zhenfeng; Kang, Haining; Wu, Weidong; Luo, Yao

    2015-03-01

    An analytical method was developed for the simultaneous determination of 25 quinolones, including danofloxacin mesylate, enrofloxacin, flumequine, oxloinic acid, ciprofloxacin, sarafloxacin, nalidixic acid, norfloxacin, and ofloxacin etc in cosmetics using direct extraction and liquid chromatography-electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). Cosmetic sample was extracted by acidified acetonitrile, defatted by n-hexane and separated on Poroshell EC-C18 column with gradient elution program using acetonitrile and water (both containing 0. 1% formic acid) as the mobile phases and analyzed by LC-ESI-MS/MS under the positive mode using multiple reaction monitoring (MRM). The interference of matrix was reduced by the matrix-matched calibration standard curve. The method showed good linearities over the range of 1-200 mg/kg for the 25 quinolones with good linear correlation coefficients (r ≥ 0.999). The method detection limit of the 25 quinolones was 1.0 mg/kg, and the recoveries of all analytes in lotion, milky and cream cosmetics matrices ranged from 87.4% to 105% at the spiked levels of 1, 5 and 10 mg/kg with the relative standard deviations (RSD) of 4.54%-19.7% (n = 6). The results indicated that this method is simple, fast and credible, and suitable for the simultaneous determination of the quinolones in the above three types of cosmetics.

  2. The separation of 99Tc from low and medium-level radioactive wastes and its determination by inductively coupled plasma mass spectrometry.

    PubMed

    Hepiegne, P; Dall'ava, D; Clement, R; Degros, J P

    1995-06-01

    A chemical separation method has been developed for the determination of (99)Tc in various types of radioactive wastes. Such a method includes (i) fusion with NaOH, (ii) extraction in a column containing methyltrioctylammonium chloride, (iii) extraction by solvent with N-benzoyl-N-phenylhydroxylamine and, (iv) measurement by inductively-coupled plasma mass spectrometry (ICP-MS). From the performance standpoint, the recovery of (99)Tc, using (99m)Tc as a yield tracer, is higher than 70%. This analytical method, as developed, ensures effective decontamination with respect to the radionuclides, insofar the decontamination factors are greater than 10(+5), whenever the residual activity may be measured. Taking into account a 3sigma counting error, the detection limit obtained with the ICP-MS technique is 1.9 mBq/ml; the method enabling hence to detect activities as low as 0.3 Bq/g, with analysed samples of 0.2 g and a radiochemical yield of 70%. Studies have been dedicated to the (99)Tc measurement, using the electrothermal vaporization ICP-MS technique, which lowers the detection limit by a factor 10, with the standard solution (0.3 pg/ml), compared with the previous ICP-MS technique.

  3. A method for the direct injection and analysis of small volume human blood spots and plasma extracts containing high concentrations of organic solvents using revered-phase 2D UPLC/MS.

    PubMed

    Rainville, Paul D; Simeone, Jennifer L; Root, Dan S; Mallet, Claude R; Wilson, Ian D; Plumb, Robert S

    2015-03-21

    The emergence of micro sampling techniques holds great potential to improve pharmacokinetic data quality, reduce animal usage, and save costs in safety assessment studies. The analysis of these samples presents new challenges for bioanalytical scientists, both in terms of sample processing and analytical sensitivity. The use of two dimensional LC/MS with, at-column-dilution for the direct analysis of highly organic extracts prepared from biological fluids such as dried blood spots and plasma is demonstrated. This technique negated the need to dry down and reconstitute, or dilute samples with water/aqueous buffer solutions, prior to injection onto a reversed-phase LC system. A mixture of model drugs, including bromhexine, triprolidine, enrofloxacin, and procaine were used to test the feasibility of the method. Finally an LC/MS assay for the probe pharmaceutical rosuvastatin was developed from dried blood spots and protein-precipitated plasma. The assays showed acceptable recovery, accuracy and precision according to US FDA guidelines. The resulting analytical method showed an increase in assay sensitivity of up to forty fold as compared to conventional methods by maximizing the amount loaded onto the system and the MS response for the probe pharmaceutical rosuvastatin from small volume samples.

  4. Comparison of matrix effects in HPLC-MS/MS and UPLC-MS/MS analysis of nine basic pharmaceuticals in surface waters.

    PubMed

    Van De Steene, Jet C; Lambert, Willy E

    2008-05-01

    When developing an LC-MS/MS-method matrix effects are a major issue. The effect of co-eluting compounds arising from the matrix can result in signal enhancement or suppression. During method development much attention should be paid to diminishing matrix effects as much as possible. The present work evaluates matrix effects from aqueous environmental samples in the simultaneous analysis of a group of 9 specific pharmaceuticals with HPLC-ESI/MS/MS and UPLC-ESI/MS/MS: flubendazole, propiconazole, pipamperone, cinnarizine, ketoconazole, miconazole, rabeprazole, itraconazole and domperidone. When HPLC-MS/MS is used, matrix effects are substantial and can not be compensated for with analogue internal standards. For different surface water samples different matrix effects are found. For accurate quantification the standard addition approach is necessary. Due to the better resolution and more narrow peaks in UPLC, analytes will co-elute less with interferences during ionisation, so matrix effects could be lower, or even eliminated. If matrix effects are eliminated with this technique, the standard addition method for quantification can be omitted and the overall method will be simplified. Results show that matrix effects are almost eliminated if internal standards (structural analogues) are used. Instead of the time-consuming and labour-intensive standard addition method, with UPLC the internal standardization can be used for quantification and the overall method is substantially simplified.

  5. Development and validation of a UPLC-MS/MS method for simultaneous determination of fotagliptin and its two major metabolites in human plasma and urine.

    PubMed

    Wang, Zhenlei; Jiang, Ji; Hu, Pei; Zhao, Qian

    2017-02-01

    Fotagliptin is a novel dipeptidyl peptidase IV inhibitor under clinical development for the treatment of Type II diabetes mellitus. The objective of this study was to develop and validate a specific and sensitive ultra-performance liquid chromatography (UPLC)-MS/MS method for simultaneous determination of fotagliptin and its two major metabolites in human plasma and urine. Methodology & results: After being pretreated using an automatized procedure, the plasma and urine samples were separated and detected using a UPLC-ESI-MS/MS method, which was validated following the international guidelines. A selective and sensitive UPLC-MS/MS method was first developed and validated for quantifying fotagliptin and its metabolite in human plasma and urine. The method was successfully applied to support the clinical study of fotagliptin in Chinese healthy subjects.

  6. Rapid analysis of aminoglycoside antibiotics in bovine tissues using disposable pipette extraction and ultrahigh performance liquid chromatography-tandem mass spectrometry.

    PubMed

    Lehotay, Steven J; Mastovska, Katerina; Lightfield, Alan R; Nuñez, Alberto; Dutko, Terry; Ng, Chilton; Bluhm, Louis

    2013-10-25

    A high-throughput qualitative screening and identification method for 9 aminoglycosides of regulatory interest has been developed, validated, and implemented for bovine kidney, liver, and muscle tissues. The method involves extraction at previously validated conditions, cleanup using disposable pipette extraction, and analysis by a 3 min ultrahigh-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method. The drug analytes include neomycin, streptomycin, dihydrosptreptomycin, and spectinomycin, which have residue tolerances in bovine in the US, and kanamicin, gentamicin, apramycin, amikacin, and hygromycin, which do not have US tolerances established in bovine tissues. Tobramycin was used as an internal standard. An additional drug, paromomycin also was validated in the method, but it was dropped during implementation due to conversion of neomycin into paromomycin. Proposed fragmentation patterns for the monitored ions of each analyte were elucidated with the aid of high resolution MS using a quadrupole-time-of-flight instrument. Recoveries from spiking experiments at regulatory levels of concern showed that all analytes averaged 70-120% recoveries in all tissues, except hygromycin averaged 61% recovery. Lowest calibrated levels were as low as 0.005 μg/g in matrix extracts, which approximately corresponded to the limit of detection for screening purposes. Drug identifications at levels <0.05 μg/g were made in spiked and/or real samples for all analytes and tissues tested. Analyses of 60 samples from 20 slaughtered cattle previously screened positive for aminoglycosides showed that this method worked well in practice. The UHPLC-MS/MS method has several advantages compared to the previous microbial inhibition screening assay, especially for distinguishing individual drugs from a mixture and improving identification of gentamicin in tissue samples. Published by Elsevier B.V.

  7. A fit-for-purpose LC-MS/MS method for the simultaneous quantitation of ATP and 2,3-DPG in human K2EDTA whole blood.

    PubMed

    Kim, Hyeryun; Kosinski, Penelope; Kung, Charles; Dang, Lenny; Chen, Yue; Yang, Hua; Chen, Yuan-Shek; Kramer, Jordyn; Liu, Guowen

    2017-09-01

    Many hemolytic anemias results in major metabolic abnormalities: two common metabolite abnormalities include increased levels of 2,3-diphosphoglycerate (2,3-DPG) and decreased levels of adenosine triphosphate (ATP). To better monitor the concentration changes of these metabolites, the development of a reliable LC-MS/MS method to quantitatively profile the concentrations of 2, 3-DPG and ATP in whole blood is essential to understand the effects of investigational therapeutics. Accurate quantification of both compounds imposes great challenges to bioanalytical scientists due to their polar, ionic and endogenous nature. Here we present an LC-MS/MS method for the reliable quantification of 2,3-DPG and ATP from K 2 EDTA human whole blood (WB) simultaneously. Whole blood samples were spiked with stable isotope labeled internal standards, processed by protein precipitation extraction, and analyzed using zwitterionic ion chromatography-hydrophilic interaction chromatography (ZIC-HILIC) coupled with tandem mass spectrometry. The linear analytical range of the assay was 50-3000μg/mL. The fit-for-purpose method demonstrated excellent accuracy and precision. The overall accuracy was within ±10.5% (%RE) for both analytes and the intra- and inter-assay precision (%CV) were less than 6.7% and 6.2% for both analytes, respectively. ATP and 2,3-DPG were found to be stable in human K 2 EDTA blood for at least 8h at 4°C, 96days when stored at -70°C and after three freeze/thaw cycles. The assay has been successfully applied to K 2 EDTA human whole blood samples to support clinical studies. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. From Leflunomide to Teriflunomide: Drug Development and Immuno-suppressive Oral Drugs in the Treatment of Multiple Sclerosis

    PubMed Central

    Aly, Lilian; Hemmer, Bernhard; Korn, Thomas

    2017-01-01

    Background: Immunosuppressive drugs have been used in the treatment of multiple sclerosis (MS) for a long time. Today, orally available second generation immunosuppressive agents have been approved or are filed for licensing as MS therapeutics. Due to semi-selective targeting of cellular processes, these second-generation immunosuppressive compounds might rather be immunomodulatory. For example, Teriflunomide inhibits the de novo pyrimidine synthesis and thus only targets rapidly proliferating cells, including lymphocytes. It is used as first line disease modifying therapy (DMT) in relapsing-remitting MS (RRMS). Methods: Review of online content related to oral immunosuppressants in MS with an emphasis on Teriflunomide. Results: Teriflunomide and Cladribine are second-generation immunosuppressants that are efficient in the treatment of MS patients. For Teriflunomide, a daily dose of 14 mg reduces the annualized relapse rate (ARR) by more than 30% and disability progression by 30% compared to placebo. Cladribine reduces the ARR by about 50% compared to placebo but has not yet been licensed due to unresolved safety concerns. We also discuss the significance of older immunosuppressive compounds including Azathioprine, Mycophenolate mofetile, and Cyclophosphamide in current MS therapy. Conclusion: Teriflunomide has shown a favorable safety and efficacy profile in RRMS and is a therapeutic option for a distinct group of adult patients with RRMS. PMID:27928949

  9. The role of epidemiology in MS research: Past successes, current challenges and future potential.

    PubMed

    Simpson, Steve; Taylor, Bruce V; van der Mei, Ingrid

    2015-07-01

    Multiple sclerosis (MS) is a multifaceted condition, with a range of environmental, behavioural and genetic factors implicated in its aetiology and clinical course. Successes in advancing our appreciation of the roles of Epstein-Barr virus, vitamin D/UV and the HLA-DRB1 locus; and our greater understanding of these and related factors' modes of action in MS and other conditions, can be attributed in no small part to the work of generations of epidemiologists. Hardly content to rest on our laurels, however, there are yet a range of unsolved conundrums in MS, including some changes in epidemiological characteristics (e.g. increasing incidence and sex ratio), to say nothing of the unresolved parts regarding what underlies MS risk and its clinical course. There is evidence that epidemiology will continue to play a crucial role in unravelling the architecture of MS causation and clinical course. While classic epidemiological methods are ongoing, novel avenues for research include gene-environment interaction studies, the world of '-omic' research, and the utilisation of mobile and social media tools to both access and track study populations, which means that the epidemiological discoveries of the past century may be but a glimpse of our understanding in the next few decades. © The Author(s), 2015.

  10. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) for analysis of endogenous steroids in the luteal phase and early pregnancy in dogs: a pilot study.

    PubMed

    Holst, Bodil S; Kushnir, Mark M; Bergquist, Jonas

    2015-12-01

    Blood samples from dogs are often limited in volume, only allowing few steroids to be quantified with immunoassays. In addition, immunoassays may be compromised by interferences such as anti-reagent antibodies. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) can be used for the simultaneous quantitation of several steroids. This has not been described in dogs before. The aims were to use LC-MS/MS to study steroid profiles in early pregnancy and luteal phase in dogs, and to determine if differences exist between pregnant (P) and nonpregnant (NP) dogs. Nine female dogs were included, 4 during a NP luteal phase, 4 during a P luteal phase, and one during one NP and one P luteal phase. Blood samples were collected around the time of the LH surge (Day 0) and on Day 26. Serum was analyzed for 5 classes of steroids, including glucocorticoids, androgens, estrogens, pregnanes, and progestins, using LC-MS/MS methods. The concentration of progesterone was significantly higher on Day 26 in P than in NP bitches. Distribution of concentrations of glucocorticoids, androgens, estrogens, or pregnanes in P and NP dogs were not statistically different. The predominating glucocorticoid was cortisol, and dihydroepiandrosterone (DHEA) was the predominating androgen. Concentration of estrone was comparable to oestradiol, whereas concentrations of pregnenolone were higher than those of 17-OH pregnenolone. Only concentration of progesterone differed between P and NP bitches, being significantly higher on Day 26 in P than in NP bitches. LC-MS/MS offers interesting possibilities for studies of canine reproductive endocrinology. © 2015 American Society for Veterinary Clinical Pathology.

  11. Recommendations and Extraction of Clinical Variables of Pediatric Multiple Sclerosis Using Common Data Elements.

    PubMed

    Newland, Pamela; Newland, John M; Hendricks-Ferguson, Verna L; Smith, Judith M; Oliver, Brant J

    2018-06-01

    The purpose of this article was to demonstrate the feasibility of using common data elements (CDEs) to search for information on the pediatric patient with multiple sclerosis (MS) and provide recommendations for future quality improvement and research in the use of CDEs for pediatric MS symptom management strategies Methods: The St. Louis Children's Hospital (SLCH), Washington University (WU) pediatrics data network was evaluated for use of CDEs identified from a database to identify variables in pediatric MS, including the key clinical features from the disease course of MS. The algorithms used were based on International Classification of Diseases, Ninth/Tenth Revision, codes and text keywords to identify pediatric patients with MS from a de-identified database. Data from a coordinating center of SLCH/WU pediatrics data network, which houses inpatient and outpatient records consisting of patients (N = 498 000), were identified, and detailed information regarding the clinical course of MS were located from the text of the medical records, including medications, presence of oligoclonal bands, year of diagnosis, and diagnosis code. There were 466 pediatric patients with MS, with a few also having the comorbid diagnosis of anxiety and depression. St. Louis Children's Hospital/WU pediatrics data network is one of the largest databases in the United States of detailed data, with the ability to query and validate clinical data for research on MS. Nurses and other healthcare professionals working with pediatric MS patients will benefit from having common disease identifiers for quality improvement, research, and practice. The increased knowledge of big data from SLCH/WU pediatrics data network has the potential to provide information for intervention and decision-making that can be personalized to the pediatric MS patient.

  12. Seven perspectives on GPCR H/D-exchange proteomics methods

    PubMed Central

    Zhang, Xi

    2017-01-01

    Recent research shows surging interest to visualize human G protein-coupled receptor (GPCR) dynamic structures using the bottom-up H/D-exchange (HDX) proteomics technology. This opinion article clarifies critical technical nuances and logical thinking behind the GPCR HDX proteomics method, to help scientists overcome cross-discipline pitfalls, and understand and reproduce the protocol at high quality. The 2010 89% HDX structural coverage of GPCR was achieved with both structural and analytical rigor. This article emphasizes systematically considering membrane protein structure stability and compatibility with chromatography and mass spectrometry (MS) throughout the pipeline, including the effects of metal ions, zero-detergent shock, and freeze-thaws on HDX result rigor. This article proposes to view bottom-up HDX as two steps to guide choices of detergent buffers and chromatography settings: (I) protein HDX labeling in native buffers, and (II) peptide-centric analysis of HDX labels, which applies (a) bottom-up MS/MS to construct peptide matrix and (b) HDX MS to locate and quantify H/D labels. The detergent-low-TCEP digestion method demystified the challenge of HDX-grade GPCR digestion. GPCR HDX proteomics is a structural approach, thus its choice of experimental conditions should let structure lead and digestion follow, not the opposite. PMID:28529698

  13. Determination of lipophilic toxins by LC/MS/MS: single-laboratory validation.

    PubMed

    Villar-González, Adriano; Rodríguez-Velasco, María Luisa; Gago-Martínez, Ana

    2011-01-01

    An LC/MS/MS method has been developed, assessed, and intralaboratory-validated for the analysis of the lipophilic toxins currently regulated by European Union legislation: okadaic acid (OA) and dinophysistoxins 1 and 2, including their ester forms; azaspiracids 1, 2, and 3; pectenotoxins 1 and 2; yessotoxin (YTX), and the analogs 45 OH-YTX, Homo YTX, and 45 OH-Homo YTX; as well as for the analysis of 13-desmetil-spirolide C. The method consists of duplicate sample extraction with methanol and direct analysis of the crude extract without further cleanup or concentration. Ester forms of OA and dinophysistoxins are detected as the parent ions after alkaline hydrolysis of the extract. The validation process of this method was performed using both fortified and naturally contaminated samples, and experiments were designed according to International Organization for Standardization, International Union of Pure and Applied Chemistry, and AOAC guidelines. With the exception of YTX in fortified samples, RSDr below 15% and RSDR were below 25%. Recovery values were between 77 and 95%, and LOQs were below 60 microg/kg. These data together with validation experiments for recovery, selectivity, robustness, traceability, and linearity, as well as uncertainty calculations, are presented in this paper.

  14. Quantification of seven β-lactam antibiotics and two β-lactamase inhibitors in human plasma using a validated UPLC-MS/MS method.

    PubMed

    Carlier, Mieke; Stove, Veronique; Roberts, Jason A; Van de Velde, Eric; De Waele, Jan J; Verstraete, Alain G

    2012-11-01

    There is an increasing interest in monitoring plasma concentrations of β-lactam antibiotics. The objective of this work was to develop and validate a rapid ultra-performance liquid chromatographic method with tandem mass spectrometric detection (UPLC-MS/MS) for simultaneous quantification of amoxicillin, ampicillin, cefuroxime, cefazolin, ceftazidime, meropenem, piperacillin, clavulanic acid and tazobactam. Sample clean-up included protein precipitation with acetonitrile and back-extraction of acetonitrile with dichloromethane. Six deuterated β-lactam antibiotics were used as internal standards. Chromatographic separation was performed on a Waters ACQUITY UPLC system using a BEH C(18) column (1.7 μm, 100 mm×2.1 mm) applying a binary gradient elution of water and acetonitrile both containing 0.1% formic acid. The total run time was 5.5 min. The developed method was validated in terms of precision, accuracy, linearity, matrix effect and recovery. The assay has now been successfully used to determine concentrations of amoxicillin/clavulanic acid, cefuroxime and meropenem in plasma samples from intensive care patients. Copyright © 2012 Elsevier B.V. and the International Society of Chemotherapy. All rights reserved.

  15. Quantitative analysis of fatty-acid-based biofuels produced by wild-type and genetically engineered cyanobacteria by gas chromatography-mass spectrometry.

    PubMed

    Guan, Wenna; Zhao, Hui; Lu, Xuefeng; Wang, Cong; Yang, Menglong; Bai, Fali

    2011-11-11

    Simple and rapid quantitative determination of fatty-acid-based biofuels is greatly important for the study of genetic engineering progress for biofuels production by microalgae. Ideal biofuels produced from biological systems should be chemically similar to petroleum, like fatty-acid-based molecules including free fatty acids, fatty acid methyl esters, fatty acid ethyl esters, fatty alcohols and fatty alkanes. This study founded a gas chromatography-mass spectrometry (GC-MS) method for simultaneous quantification of seven free fatty acids, nine fatty acid methyl esters, five fatty acid ethyl esters, five fatty alcohols and three fatty alkanes produced by wild-type Synechocystis PCC 6803 and its genetically engineered strain. Data obtained from GC-MS analyses were quantified using internal standard peak area comparisons. The linearity, limit of detection (LOD) and precision (RSD) of the method were evaluated. The results demonstrated that fatty-acid-based biofuels can be directly determined by GC-MS without derivation. Therefore, rapid and reliable quantitative analysis of fatty-acid-based biofuels produced by wild-type and genetically engineered cyanobacteria can be achieved using the GC-MS method founded in this work. Copyright © 2011 Elsevier B.V. All rights reserved.

  16. Polyfluoroalkyl chemicals in house dust

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kato, Kayoko; Calafat, Antonia M., E-mail: acalafat@cdc.gov; Needham, Larry L.

    2009-07-15

    We developed a high throughput analytical method using on-line solid phase extraction coupled with isotope dilution high-performance liquid chromatography-tandem mass spectrometry (on-line SPE-HPLC-MS/MS) to simultaneously determine the concentrations of 17 polyfluoroalkyl chemicals (PFCs) in house dust. The sample preparation includes dispersion of the dust samples in 0.1 M formic acid:MeOH (1:1), followed by agitation and filtration, addition of the isotope-labeled internal standard solution to the filtrate, and analysis by on-line SPE-HPLC-MS/MS. The limits of quantitation were <4.0 ng/g. The method accuracies ranged between 73.2% and 100.2% for the different analytes at two spike levels. We confirmed the validity of themore » method by analyzing 39 household dust samples collected in 2004. Of the 17 PFCs measured, 6 of them-perfluorobutane sulfonate (PFBuS), N-ethyl-perfluorooctane sulfonamide, 2-(N-ethyl-perfluorooctane sulfonamido) acetic acid (Et-PFOSA-AcOH), 2-(N-methyl-perfluorooctane sulfonamido) ethanol (Me-PFOSA-EtOH), perfluorohexane sulfonate (PFHxS), and perfluorooctane sulfonate (PFOS)-had detection frequencies >70%. We detected PFOS, PFBuS, and PFHxS at the highest median concentration, followed by Et-PFOSA-AcOH and Me-PFOSA-EtOH.« less

  17. Development of a high performance liquid chromatography method and a liquid chromatography-tandem mass spectrometry method with the pressurized liquid extraction for the quantification and confirmation of sulfonamides in the foods of animal origin.

    PubMed

    Yu, Huan; Tao, Yanfei; Chen, Dongmei; Wang, Yulian; Huang, Lingli; Peng, Dapeng; Dai, Menghong; Liu, Zhenli; Wang, Xu; Yuan, Zonghui

    2011-09-01

    The residues of sulfonamides (SAs) in the foods of animal origin are of the major concern because they are harmful to the consumer's health and could induce pathogens to develop resistance. Rapid and efficient determination methods are urgently in need. A quantitative high performance liquid chromatography method (HPLC) and a confirmative liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the simultaneous determination of 18 sulfonamides such as sulfamidinum, sulfanilamide, sulfisomidine, sulfadiazine, sulfapyridine, sulfathiazole, sulfamerazine, sulfadimidine, sulfamethoxypyridazine, sulfamethoxydiazine, sulfisoxazole, sulfachloropyridazine, sulfamethoxazole, sulfamonomethoxine, sulfadoxine, sulfaclozine, sulfadimethoxine, sulfaquinoxaline in the muscles, livers and kidneys of swine, bovine and chicken were developed and validated. The sample preparation procedures included a pressurized liquid extraction (PLE) with acetonitrile conducted at elevated temperature (70°C) and pressure (1400 psi). After clean-up with hydrophilic-lipophilic balance cartridge, the extraction solution was concentrated and analyzed by HPLC and LC-MS/MS analysis. 18 SAs were separated by the HPLC with a Zorbax SB-Aq-C18 column and the mobile phase of methanol/acetonitrile/1% acetic acid with a gradient system. The wavelength of UV for the HPLC detection was set at 285 nm. The LC-MS/MS analysis was achieved with a Hypersil Golden column and the mobile phase of acetonitrile and 0.1% formic acid aqueous solution with two gradient systems. The Limits of detection (LOD) and the limits of quantitation (LOQ) were 3 μg/kg and 10 μg/kg, respectively, for both of the HPLC and LC-MS/MS. Linearity was obtained with an average coefficient of determination (R) higher than 0.9980 over a dynamic range from the LOQ value up to 5000 μg/kg. The recoveries of the methods range from 71.1% to 118.3% with the relative standard derivation less than 13%. The peaks of interest with no interferences were observed throughout the chromatographic run. The sample pretreatment provided efficient extraction and cleanup that enables a sensitive and rugged determination of 18 SAs, the obtained results revealed that PLE, in comparison with other sample preparation methods applied, has significantly higher efficacy for SAs isolation from animal tissues. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. Simultaneous quantification of cholesterol sulfate, androgen sulfates, and progestagen sulfates in human serum by LC-MS/MS[S

    PubMed Central

    Sánchez-Guijo, Alberto; Oji, Vinzenz; Hartmann, Michaela F.; Traupe, Heiko; Wudy, Stefan A.

    2015-01-01

    Steroids are primarily present in human fluids in their sulfated forms. Profiling of these compounds is important from both diagnostic and physiological points of view. Here, we present a novel method for the quantification of 11 intact steroid sulfates in human serum by LC-MS/MS. The compounds analyzed in our method, some of which are quantified for the first time in blood, include cholesterol sulfate, pregnenolone sulfate, 17-hydroxy-pregnenolone sulfate, 16-α-hydroxy-dehydroepiandrosterone sulfate, dehydroepiandrosterone sulfate, androstenediol sulfate, androsterone sulfate, epiandrosterone sulfate, testosterone sulfate, epitestosterone sulfate, and dihydrotestosterone sulfate. The assay was conceived to quantify sulfated steroids in a broad range of concentrations, requiring only 300 μl of serum. The method has been validated and its performance was studied at three quality controls, selected for each compound according to its physiological concentration. The assay showed good linearity (R2 > 0.99) and recovery for all the compounds, with limits of quantification ranging between 1 and 80 ng/ml. Averaged intra-day and between-day precisions (coefficient of variation) and accuracies (relative errors) were below 10%. The method has been successfully applied to study the sulfated steroidome in diseases such as steroid sulfatase deficiency, proving its diagnostic value. This is, to our best knowledge, the most comprehensive method available for the quantification of sulfated steroids in human blood. PMID:26239050

  19. GC/MS determination of amines following exhaustive trifluoroacetylation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomson, J.S.; Green, J.B.; McWilliams, T.B.

    An analytical method for trifluoroacetylation of aromatic amines and GC/MS of the resulting derivatives has been developed. The key feature of the method is its capability to differentiate d tertiary amines; since, using the conditions described in the report, most primary, secondary, an primary amines add two and secondary amines add one trifluoroacetyl group. In general, tertiary amines do not react. Since conventional trifluoroacetylation procedures introduce only a single trifluoroacetyl group into both primary and secondary aminess the procedure reported here improves GC/MS identification of the relatively large number of isomers of nitrogen compounds found in petroleum or similarly complexmore » mixtures. For example, using exhaustive trifluoroacetylation, it is possible to differentiate isomeric forms of C{sub 9}H{sub 11}N (e.g., cyclohexenopyridines, aminoindans, 1,2,3,4-tetrahydroquinoline and tetrahydroisoquinolines). Examples of the application of the method to petroleum and coal liquid products are provided. Because of the limited thermal stability of the derivatives of primary amines, the method is applicable only to distillates boiling below 370{degrees}C (700{degrees}F). To expedite utilization of the method by others, GC retention indices and relative GC/MS total ion current response factors for 102 trifluoroacetyl derivatives are included in the body of the report and their 70 ev mass spectra are reported in Appendix A.« less

  20. Simultaneous detection of perchlorate and bromate using rapid high-performance ion exchange chromatography-tandem mass spectrometry and perchlorate removal in drinking water.

    PubMed

    West, Danielle M; Mu, Ruipu; Gamagedara, Sanjeewa; Ma, Yinfa; Adams, Craig; Eichholz, Todd; Burken, Joel G; Shi, Honglan

    2015-06-01

    Perchlorate and bromate occurrence in drinking water causes health concerns due to their effects on thyroid function and carcinogenicity, respectively. The purpose of this study was threefold: (1) to advance a sensitive method for simultaneous rapid detection of perchlorate and bromate in drinking water system, (2) to systematically study the occurrence of these two contaminants in Missouri drinking water treatment systems, and (3) to examine effective sorbents for minimizing perchlorate in drinking water. A rapid high-performance ion exchange chromatography-tandem mass spectrometry (HPIC-MS/MS) method was advanced for simultaneous detection of perchlorate and bromate in drinking water. The HPIC-MS/MS method was rapid, required no preconcentration of the water samples, and had detection limits for perchlorate and bromate of 0.04 and 0.01 μg/L, respectively. The method was applied to determine perchlorate and bromate concentrations in total of 23 selected Missouri drinking water treatment systems during differing seasons. The water systems selected include different source waters: groundwater, lake water, river water, and groundwater influenced by surface water. The concentrations of perchlorate and bromate were lower than or near to method detection limits in most of the drinking water samples monitored. The removal of perchlorate by various adsorbents was studied. A cationic organoclay (TC-99) exhibited effective removal of perchlorate from drinking water matrices.

  1. Quantitation of brinzolamide in dried blood spots by a novel LC-QTOF-MS/MS method.

    PubMed

    Foivas, Anargyros; Malenović, Anđelija; Kostić, Nađa; Božić, Marija; Knežević, Miroslav; Loukas, Yannis L; Dotsikas, Yannis

    2016-02-05

    In the current study, a rapid and sensitive LC-QTOF-MS/MS method for the determination of brinzolamide in dried blood spots (DBS) was developed and validated. This novel sample collection, storage and transfer technique was suitable for analyzing a drug with high distribution into red blood cells and negligible plasma levels. The method included an isocratic mobile phase consisting of methanol and 10mM ammonium formate (90:10, v/v) and detection in positive electrospray mode (ESI+). The flow rate was adjusted to 0.350mL/min yielding retention times of 1.7min for both brinzolamide and internal standard (IS) rabeprazole on a Cyano analytical column, respectively. The validation of the proposed method over the concentration range 0.500-20.0μg/mL was performed in compliance with EMEA and FDA guidelines, assessing all major performance characteristics. Inter- and intra- assay precisions were less than 14%, while inter- and intra- assay accuracies varied from 92.2 to 111%. No matrix effect was observed and the mean brinzolamide extraction recovery was 93.5%. The method was successfully applied to real DBS samples from patients in steady state condition, receiving brinzolamide ophthalmic suspension 1% (w/v) for several months. Initial concentrations were corrected due to hematocrit effect, using image processing algorithm written in Matlab. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Comprehensive analysis of the lipophilic reactive carbonyls present in biological specimens by LC/ESI-MS/MS.

    PubMed

    Tomono, Susumu; Miyoshi, Noriyuki; Ohshima, Hiroshi

    2015-04-15

    A new analytical method has been developed for profiling lipophilic reactive carbonyls (RCs) such as aldehydes and ketones in biological samples using liquid chromatography/electrospray ionization tandem mass spectrometry (LC/ESI-MS/MS) with selected reaction monitoring (SRM). The method consists of several phases, including (1) extraction of lipophilic RCs with a chloroform/methanol mixture; (2) derivatization of the extracted RCs with dansyl hydrazine (DH); and (3) SRM detection of the characteristic product ion of the 5-dimethylaminonaphthalene-1-sulfonyl moiety (m/z 236.1). The analytical results were expressed as RC maps, which allowed for the occurrence and levels of different lipophilic RCs to be visualized. We also developed a highly reproducible and accurate method to extract, purify and derivatize RCs in small volumes of biological specimens. This method was applied to the detection of free RCs in mice plasma samples, and resulted in the detection of more than 400 RCs in samples obtained from C57BL/6J mice. Thirty-four of these RCs were identified by comparison with authentic RCs. This method could be used to investigate the levels of RCs in biological and environmental samples, as well as studying the role of lipid peroxidation in oxidative stress related-disorders and discovering new biomarkers for the early diagnosis of these diseases. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. Testing isotopic labeling with [¹³C₆]glucose as a method of advanced glycation sites identification.

    PubMed

    Kielmas, Martyna; Kijewska, Monika; Stefanowicz, Piotr; Szewczuk, Zbigniew

    2012-12-01

    The Maillard reaction occurring between reducing sugars and reactive amino groups of biomolecules leads to the formation of a heterogeneous mixture of compounds: early, intermediate, and advanced glycation end products (AGEs). These compounds could be markers of certain diseases and of the premature aging process. Detection of Amadori products can be performed by various methods, including MS/MS techniques and affinity chromatography on immobilized boronic acid. However, the diversity of the structures of AGEs makes detection of these compounds more difficult. The aim of this study was to test a new method of AGE identification based on isotope (13)C labeling. The model protein (hen egg lysozyme) was modified with an equimolar mixture of [(12)C(6)]glucose and [(13)C(6)]glucose and then subjected to reduction of the disulfide bridges followed by tryptic hydrolysis. The digest obtained was analyzed by LC-MS. The glycation products were identified on the basis of characteristic isotopic patterns resulting from the use of isotopically labeled glucose. This method allowed identification of 38 early Maillard reaction products and five different structures of the end glycation products. This isotopic labeling technique combined with LC-MS is a sensitive method for identification of advanced glycation end products even if their chemical structure is unknown. Copyright © 2012 Elsevier Inc. All rights reserved.

  4. Development of analytical methods for multiplex bio-assay with inductively coupled plasma mass spectrometry.

    PubMed

    Ornatsky, Olga I; Kinach, Robert; Bandura, Dmitry R; Lou, Xudong; Tanner, Scott D; Baranov, Vladimir I; Nitz, Mark; Winnik, Mitchell A

    2008-01-01

    Advances in the development of highly multiplexed bio-analytical assays with inductively coupled plasma mass spectrometry (ICP-MS) detection are discussed. Use of novel reagents specifically designed for immunological methods utilizing elemental analysis is presented. The major steps of method development, including selection of elements for tags, validation of tagged reagents, and examples of multiplexed assays, are considered in detail. The paper further describes experimental protocols for elemental tagging of antibodies, immunostaining of live and fixed human leukemia cells, and preparation of samples for ICP-MS analysis. Quantitative analysis of surface antigens on model cell lines using a cocktail of seven lanthanide labeled antibodies demonstrated high specificity and concordance with conventional immunophenotyping.

  5. PARPs database: A LIMS systems for protein-protein interaction data mining or laboratory information management system

    PubMed Central

    Droit, Arnaud; Hunter, Joanna M; Rouleau, Michèle; Ethier, Chantal; Picard-Cloutier, Aude; Bourgais, David; Poirier, Guy G

    2007-01-01

    Background In the "post-genome" era, mass spectrometry (MS) has become an important method for the analysis of proteins and the rapid advancement of this technique, in combination with other proteomics methods, results in an increasing amount of proteome data. This data must be archived and analysed using specialized bioinformatics tools. Description We herein describe "PARPs database," a data analysis and management pipeline for liquid chromatography tandem mass spectrometry (LC-MS/MS) proteomics. PARPs database is a web-based tool whose features include experiment annotation, protein database searching, protein sequence management, as well as data-mining of the peptides and proteins identified. Conclusion Using this pipeline, we have successfully identified several interactions of biological significance between PARP-1 and other proteins, namely RFC-1, 2, 3, 4 and 5. PMID:18093328

  6. Tandem mass spectrometry: analysis of complex mixtures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singleton, K.E.

    1985-01-01

    Applications of tandem mass spectrometry (MS/MS) for the analysis of complex mixtures results in increased specificity and selectivity by using a variety of reagent gases in both negative and positive ion modes. Natural isotopic abundance ratios were examined in both simple and complex mixtures using parent, daughter and neutral loss scans. MS/MS was also used to discover new compounds. Daughter scans were used to identify seven new alkaloids in a cactus species. Three of these alkaloids were novel compounds, and included the first simple, fully aromatic isoquinoline alkaloids reported in Cactaceae. MS/MS was used to characterize the chemical reaction productsmore » of coal in studies designed to probe its macromolecular structure. Negative ion chemical ionization was utilized to study reaction products resulting from the oxidation of coal. Possible structural units in the precursor coal were predicted based on the reaction products identified, aliphatic and aromatic acids and their anhydrides. The MS/MS method was also used to characterize reaction products resulting from coal liquefaction and/or extraction. These studies illustrate the types of problems for which MS/MS is useful. Emphasis has been placed on characterization of complex mixtures by selecting experimental parameters which enhance the information obtained. The value of using MS/MS in conjunction with other analytical techniques as well as the chemical pretreatment is demonstrated.« less

  7. Prevalence of Metabolic Syndrome Components in an Urban Mexican Sample: Comparison between Two Classifications

    PubMed Central

    Isordia-Salas, Irma; Santiago-Germán, David; Rodrìguez-Navarro, Helem; Almaráz-Delgado, Martín; Leaños-Miranda, Alfredo; Anaya-Gómez, Francisco; Borrayo-Sánchez, Gabriela; Majluf-Cruz, Abraham

    2012-01-01

    Background. The aim of this study was to examine the prevalence of metabolic syndrome (MS) components in an urban Mexican sample. Methods. A total of 854 subjects were included. Anthropometric, blood pressure measurements, clinical data, and overnight fasting blood samples were obtained from all subjects. Results. In accordance with definitions by the American Heart Association/ National Heart, Lung, and Blood Institute (AHA/NHLBI) and the International Diabetes Federation (IDF), the prevalence of MS among participants was 59.7 and 68.7%, respectively. The prevalence of MS was higher in women and in individuals older than 45 years of age. More than 40% of the subjects fulfilled four criterions of MS according to both definitions. Conclusions. There was a high prevalence of MS components in an urban Mexican sample. Therefore, strong strategies had to be developed for early detection of MS and its components to prevent DMT2 and atherothrombotic complications in these patients. PMID:22203834

  8. Mass Spec Studio for Integrative Structural Biology

    PubMed Central

    Rey, Martial; Sarpe, Vladimir; Burns, Kyle; Buse, Joshua; Baker, Charles A.H.; van Dijk, Marc; Wordeman, Linda; Bonvin, Alexandre M.J.J.; Schriemer, David C.

    2015-01-01

    SUMMARY The integration of biophysical data from multiple sources is critical for developing accurate structural models of large multiprotein systems and their regulators. Mass spectrometry (MS) can be used to measure the insertion location for a wide range of topographically sensitive chemical probes, and such insertion data provide a rich, but disparate set of modeling restraints. We have developed a software platform that integrates the analysis of label-based MS data with protein modeling activities (Mass Spec Studio). Analysis packages can mine any labeling data from any mass spectrometer in a proteomics-grade manner, and link labeling methods with data-directed protein interaction modeling using HADDOCK. Support is provided for hydrogen/ deuterium exchange (HX) and covalent labeling chemistries, including novel acquisition strategies such as targeted HX-tandem MS (MS2) and data-independent HX-MS2. The latter permits the modeling of highly complex systems, which we demonstrate by the analysis of microtubule interactions. PMID:25242457

  9. Development and Applications of Liquid Sample Desorption Electrospray Ionization Mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Zheng, Qiuling; Chen, Hao

    2016-06-01

    Desorption electrospray ionization mass spectrometry (DESI-MS) is a recent advance in the field of analytical chemistry. This review surveys the development of liquid sample DESI-MS (LS-DESI-MS), a variant form of DESI-MS that focuses on fast analysis of liquid samples, and its novel analy-tical applications in bioanalysis, proteomics, and reaction kinetics. Due to the capability of directly ionizing liquid samples, liquid sample DESI (LS-DESI) has been successfully used to couple MS with various analytical techniques, such as microfluidics, microextraction, electrochemistry, and chromatography. This review also covers these hyphenated techniques. In addition, several closely related ionization methods, including transmission mode DESI, thermally assisted DESI, and continuous flow-extractive DESI, are briefly discussed. The capabilities of LS-DESI extend and/or complement the utilities of traditional DESI and electrospray ionization and will find extensive and valuable analytical application in the future.

  10. Characterization of rhamnolipids by liquid chromatography/mass spectrometry after solid-phase extraction.

    PubMed

    Behrens, Beate; Engelen, Jeannine; Tiso, Till; Blank, Lars Mathias; Hayen, Heiko

    2016-04-01

    Rhamnolipids are surface-active agents with a broad application potential that are produced in complex mixtures by bacteria of the genus Pseudomonas. Analysis from fermentation broth is often characterized by laborious sample preparation and requires hyphenated analytical techniques like liquid chromatography coupled to mass spectrometry (LC-MS) to obtain detailed information about sample composition. In this study, an analytical procedure based on chromatographic method development and characterization of rhamnolipid sample material by LC-MS as well as a comparison of two sample preparation methods, i.e., liquid-liquid extraction and solid-phase extraction, is presented. Efficient separation was achieved under reversed-phase conditions using a mixed propylphenyl and octadecylsilyl-modified silica gel stationary phase. LC-MS/MS analysis of a supernatant from Pseudomonas putida strain KT2440 pVLT33_rhlABC grown on glucose as sole carbon source and purified by solid-phase extraction revealed a total of 20 congeners of di-rhamnolipids, mono-rhamnolipids, and their biosynthetic precursors 3-(3-hydroxyalkanoyloxy)alkanoic acids (HAAs) with different carbon chain lengths from C8 to C14, including three rhamnolipids with uncommon C9 and C11 fatty acid residues. LC-MS and the orcinol assay were used to evaluate the developed solid-phase extraction method in comparison with the established liquid-liquid extraction. Solid-phase extraction exhibited higher yields and reproducibility as well as lower experimental effort.

  11. Application of dispersive solid phase extraction for trace analysis of toxic chemicals in foods.

    PubMed

    Neely, Sarah; Martin, Jordan; da Cruz, Natalia Ferreira; Piester, Gavin; Robinson, Morgan; Okoniewski, Richard; Tran, Buu N

    2018-05-29

    The objectives of this study were to develop and validate a method for the identification of toxic organic chemicals, including groups of controlled substances, alkaloids and pesticides that are highly toxic and considered threats to public health. This project aims to ensure our laboratory's readiness to respond to emergencies involving our food supply in cooperation with the Food Emergency Response Network (FERN) program. The food matrices were homogenized in a blender or food processor prior to extraction with an acetonitrile-water mixture using a QuEChERS (Quick, Easy, Cheap, Effective, Rugged, and Safe) procedure. The extracts were then analyzed by either gas chromatography-mass spectrometry (GC-MS) or liquid chromatography-electrospray tandem mass spectrometry (LC-ESI/MS/MS). Method validation was performed on a variety of food matrices including lettuce, grapes, milk, chicken, pork and beef. MDLs for the toxic compounds ranged from 0.01 to 0.66 mg/kg (ppm). The findings in this study will provide a valuable resource for the determination of toxic chemicals in food matrices for emergency response situations. Copyright © 2018. Published by Elsevier B.V.

  12. Development and Single-Laboratory Validation of a Liquid Chromatography Tandem Mass Spectrometry Method for Quantitation of Tetrodotoxin in Mussels and Oysters.

    PubMed

    Turner, Andrew D; Boundy, Michael J; Rapkova, Monika Dhanji

    2017-09-01

    In recent years, evidence has grown for the presence of tetrodotoxin (TTX) in bivalve mollusks, leading to the potential for consumers of contaminated products to be affected by Tetrodotoxin Shellfish Poisoning (TSP). A single-laboratory validation was conducted for the hydrophilic interaction LC (HILIC) tandem MS (MS/MS) analysis of TTX in common mussels and Pacific oysters-the bivalve species that have been found to contain TTXs in the United Kingdom in recent years. The method consists of a single-step dispersive extraction in 1% acetic acid, followed by a carbon SPE cleanup step before dilution and instrumental analysis. The full method was developed as a rapid tool for the quantitation of TTX, as well as for the associated analogs 4-epi-TTX; 5,6,11-trideoxy TTX; 11-nor TTX-6-ol; 5-deoxy TTX; and 4,9-anhydro TTX. The method can also be run as the acquisition of TTX together with paralytic shellfish toxins. Results demonstrated acceptable method performance characteristics for specificity, linearity, recovery, ruggedness, repeatability, matrix variability, and within-laboratory reproducibility for the analysis of TTX. The LOD and LOQ were fit-for-purpose in comparison to the current action limit for TTX enforced in The Netherlands. In addition, aspects of method performance (LOD, LOQ, and within-laboratory reproducibility) were found to be satisfactory for three other TTX analogs (11-nor TTX-6-ol, 5-deoxy TTX, and 4,9-anhydro TTX). The method was found to be practical and suitable for use in regulatory testing, providing rapid turnaround of sample analysis. Plans currently underway on a full collaborative study to validate a HILIC-MS/MS method for paralytic shellfish poisoning toxins will be extended to include TTX in order to generate international acceptance, ultimately for use as an alternative official control testing method should regulatory controls be adopted.

  13. Development and validation of a multiresidue method for the analysis of polybrominated diphenyl ethers, new brominated and organophosphorus flame retardants in sediment, sludge and dust.

    PubMed

    Cristale, Joyce; Lacorte, Silvia

    2013-08-30

    This study presents a multiresidue method for simultaneous extraction, clean-up and analysis of priority and emerging flame retardants in sediment, sewage sludge and dust. Studied compounds included eight polybrominated diphenyl ethers congeners, nine new brominated flame retardants and ten organophosphorus flame retardants. The analytical method was based on ultrasound-assisted extraction with ethyl acetate/cyclohexane (5:2, v/v), clean-up with Florisil cartridges and analysis by gas chromatography coupled to tandem mass spectrometry (GC-EI-MS/MS). Method development and validation protocol included spiked samples, certified reference material (for dust), and participation in an interlaboratory calibration. The method proved to be efficient and robust for extraction and determination of three families of flame retardants families in the studied solid matrices. The method was applied to river sediment, sewage sludge and dust samples, and allowed detection of 24 among the 27 studied flame retardants. Organophosphate esters, BDE-209 and decabromodiphenyl ethane were the most ubiquitous contaminants detected. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. De novo peptide sequencing using CID and HCD spectra pairs.

    PubMed

    Yan, Yan; Kusalik, Anthony J; Wu, Fang-Xiang

    2016-10-01

    In tandem mass spectrometry (MS/MS), there are several different fragmentation techniques possible, including, collision-induced dissociation (CID) higher energy collisional dissociation (HCD), electron-capture dissociation (ECD), and electron transfer dissociation (ETD). When using pairs of spectra for de novo peptide sequencing, the most popular methods are designed for CID (or HCD) and ECD (or ETD) spectra because of the complementarity between them. Less attention has been paid to the use of CID and HCD spectra pairs. In this study, a new de novo peptide sequencing method is proposed for these spectra pairs. This method includes a CID and HCD spectra merging criterion and a parent mass correction step, along with improvements to our previously proposed algorithm for sequencing merged spectra. Three pairs of spectral datasets were used to investigate and compare the performance of the proposed method with other existing methods designed for single spectrum (HCD or CID) sequencing. Experimental results showed that full-length peptide sequencing accuracy was increased significantly by using spectra pairs in the proposed method, with the highest accuracy reaching 81.31%. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  15. A multiclass multiresidue LC-MS/MS method for analysis of veterinary drugs in bovine kidney

    USDA-ARS?s Scientific Manuscript database

    The increased efficiency permitted by multiclass, multiresidue methods has made such approaches very attractive to laboratories involved in monitoring veterinary drug residues in animal tissues. In this current work, evaluation of a multiclass multiresidue LC-MS/MS method in bovine kidney is describ...

  16. Development and validation of an LC-MS/MS method for quantification of cyclic guanosine 3',5'-monophosphate (cGMP) in clinical applications: a comparison with a EIA method.

    PubMed

    Zhang, Yanhua; Dufield, Dawn; Klover, Jon; Li, Wenlin; Szekely-Klepser, Gabriella; Lepsy, Christopher; Sadagopan, Nalini

    2009-02-15

    An LC-MS/MS method was developed and validated to quantify endogenous cyclic guanosine 3',5'-monophosphate (cGMP) in human plasma. The LC-MS/MS and competitive enzyme immunoassay (EIA) assays were compared. cGMP concentrations of 20 human plasma samples were measured by both methods. For the MS-based assay, plasma samples were subjected to a simple protein precipitation procedure by acetonitrile prior to analysis by electrospray ionization LC-MS/MS. De-protonated analytes generated in negative ionization mode were monitored through multiple reaction monitoring (MRM). A stable isotope-labeled internal standard, (13)C(10),(15)N(5)-cGMP, which was biosynthesized in-house, was used in the LC-MS/MS method. The competitive EIA was validated using a commercially available cGMP fluorescence assay kit. The intra-assay accuracy and precision for MS-based assay for cGMP were 6-10.1% CV and -3.6% to 7.3% relative error (RE), respectively, while inter-assay precision and accuracy were 5.6-8.1% CV and -2.1% to 6.3% RE, respectively. The intra-assay accuracy and precision for EIA were 17.9-27.1% CV and -4.9% to 24.5% RE, respectively, while inter-assay precision and accuracy were 15.1-39.5% CV and -30.8% to 4.37% RE, respectively. Near the lower limits of detection, there was little correlation between the cGMP concentration values in human plasma generated by these two methods (R(2)=0.197, P=0.05). Overall, the MS-based assay offered better selectivity, recovery, precision and accuracy over a linear range of 0.5-20ng/mL. The LC-MS/MS method provides an effective tool for the quantitation of cGMP to support clinical mechanistic studies of curative pharmaceuticals.

  17. Development and validation of an LC-ESI-MS/MS method for the quantification of D-84, reboxetine and citalopram for their use in MS Binding Assays addressing the monoamine transporters hDAT, hSERT and hNET.

    PubMed

    Neiens, Patrick; De Simone, Angela; Ramershoven, Anna; Höfner, Georg; Allmendinger, Lars; Wanner, Klaus T

    2018-03-03

    MS Binding Assays represent a label-free alternative to radioligand binding assays. In this study, we present an LC-ESI-MS/MS method for the quantification of (R,R)-4-(2-benzhydryloxyethyl)-1-(4-fluorobenzyl)piperidin-3-ol [(R,R)-D-84, (R,R)-1], (S,S)-reboxetine [(S,S)-2], and (S)-citalopram [(S)-3] employed as highly selective nonlabeled reporter ligands in MS Binding Assays addressing the dopamine [DAT, (R,R)-D-84], norepinephrine [NET, (S,S)-reboxetine] and serotonin transporter [SERT, (S)-citalopram], respectively. The developed LC-ESI-MS/MS method uses a pentafluorphenyl stationary phase in combination with a mobile phase composed of acetonitrile and ammonium formate buffer for chromatography and a triple quadrupole mass spectrometer in the multiple reaction monitoring mode for mass spectrometric detection. Quantification is based on deuterated derivatives of all three analytes serving as internal standards. The established LC-ESI-MS/MS method enables fast, robust, selective and highly sensitive quantification of all three reporter ligands in a single chromatographic run. The method was validated according to the Center for Drug Evaluation and Research (CDER) guideline for bioanalytical method validation regarding selectivity, accuracy, precision, calibration curve and sensitivity. Finally, filtration-based MS Binding Assays were performed for all three monoamine transporters based on this LC-ESI-MS/MS quantification method as read out. The affinities determined in saturation experiments for (R,R)-D-84 toward hDAT, for (S,S)-reboxetine toward hNET, and for (S)-citalopram toward hSERT, respectively, were in good accordance with results from literature, clearly demonstrating that the established MS Binding Assays have the potential to be an efficient alternative to radioligand binding assays widely used for this purpose so far. Copyright © 2018 John Wiley & Sons, Ltd.

  18. Advantages of a validated UPLC-MS/MS standard addition method for the quantification of A-type dimeric and trimeric proanthocyanidins in cranberry extracts in comparison with well-known quantification methods.

    PubMed

    van Dooren, Ines; Foubert, Kenn; Theunis, Mart; Naessens, Tania; Pieters, Luc; Apers, Sandra

    2018-01-30

    The berries of Vaccinium macrocarpon, cranberry, are widely used for the prevention of urinary tract infections. This species contains A-type proanthocyanidins (PACs), which intervene in the initial phase of the development of urinary tract infections by preventing the adherence of Escherichia coli by their P-type fimbriae to uroepithelial cells. Unfortunately, the existing clinical studies used different cranberry preparations, which were poorly standardized. Because of this, the results were hard to compare, which led sometimes to conflicting results. Currently, PACs are quantified using the rather non-specific spectrophotometric 4-dimethylaminocinnamaldehyde (DMAC) method. In addition, a normal phase HPTLC-densitometric method, a HPLC-UV method and three LC-MS/MS methods for quantification of procyanidin A2 were recently published. All these methods contain some shortcomings and errors. Hence, the development and validation of a fast and sensitive standard addition LC-MS/MS method for the simultaneous quantification of A-type dimers and trimers in a cranberry dry extract was carried out. A linear calibration model could be adopted for dimers and, after logaritmic transformation, for trimers. The maximal interday and interconcentration precision was found to be 4.86% and 4.28% for procyanidin A2, and 5.61% and 7.65% for trimeric PACs, which are all acceptable values for an analytical method using LC-MS/MS. In addition, twelve different cranberry extracts were analyzed by means of the newly validated method and other widely used methods. There appeared to be an enormous variation in dimeric and trimeric PAC content. Comparison of these results with LC-MS/MS analysis without standard addition showed the presence of matrix effects for some of the extracts and proved the necessity of standard addition. A comparison of the well-known and widely used DMAC method, the butanol-HCl assay and this newly developed LC-MS/MS method clearly indicated the need for a reliable method able to quantify A-type PACs, which are considered to be the pharmacologically active constituents of cranberry, since neither the DMAC or butanol-HCl assays are capable of distinguishing between A and B-type PACs and therefore cannot detect adulterations with, for example, extracts with a high B-type PAC content. Hence, the combination of the DMAC method or butanol-HCl assay with this more specific LC-MS/MS assay could overcome these shortcomings. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. SimExTargId: A comprehensive package for real-time LC-MS data acquisition and analysis.

    PubMed

    Edmands, William M B; Hayes, Josie; Rappaport, Stephen M

    2018-05-22

    Liquid chromatography mass spectrometry (LC-MS) is the favored method for untargeted metabolomic analysis of small molecules in biofluids. Here we present SimExTargId, an open-source R package for autonomous analysis of metabolomic data and real-time observation of experimental runs. This simultaneous, fully automated and multi-threaded (optional) package is a wrapper for vendor-independent format conversion (ProteoWizard), xcms- and CAMERA- based peak-picking, MetMSLine-based pre-processing and covariate-based statistical analysis. Users are notified of detrimental instrument drift or errors by email. Also included are two shiny applications, targetId for real-time MS2 target identification, and peakMonitor to monitor targeted metabolites. SimExTargId is publicly available under GNU LGPL v3.0 license at https://github.com/JosieLHayes/simExTargId, which includes a vignette with example data. SimExTargId should be installed on a dedicated data-processing workstation or server that is networked to the LC-MS platform to facilitate MS1 profiling of metabolomic data. josie.hayes@berkeley.edu. Supplementary data are available at Bioinformatics online.

  20. An integrated platform for directly widely-targeted quantitative analysis of feces part I: Platform configuration and method validation.

    PubMed

    Song, Yuelin; Song, Qingqing; Li, Jun; Zheng, Jiao; Li, Chun; Zhang, Yuan; Zhang, Lingling; Jiang, Yong; Tu, Pengfei

    2016-07-08

    Direct analysis is of great importance to understand the real chemical profile of a given sample, notably biological materials, because either chemical degradation or diverse errors and uncertainties might be resulted from sophisticated protocols. In comparison with biofluids, it is still challenging for direct analysis of solid biological samples using high performance liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS). Herein, a new analytical platform was configured by online hyphenating pressurized liquid extraction (PLE), turbulent flow chromatography (TFC), and LC-MS/MS. A facile, but robust PLE module was constructed based on the phenomenon that noticeable back-pressure can be generated during rapid fluid passing through a narrow tube. TFC column that is advantageous at extracting low molecular analytes from rushing fluid was employed to link at the outlet of the PLE module to capture constituents-of-interest. An electronic 6-port/2-position valve was introduced between TFC column and LC-MS/MS to fragment each measurement into extraction and elution phases, whereas LC-MS/MS took the charge of analyte separation and monitoring. As a proof of concept, simultaneous determination of 24 endogenous substances including eighteen steroids, five eicosanoids, and one porphyrin in feces was carried out in this paper. Method validation assays demonstrated the analytical platform to be qualified for directly simultaneous measurement of diverse endogenous analytes in fecal matrices. Application of this integrated platform on homolog-focused profiling of feces is discussed in a companion paper. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Global Profiling of Various Metabolites in Platycodon grandiflorum by UPLC-QTOF/MS.

    PubMed

    Lee, Jae Won; Ji, Seung-Heon; Kim, Geum-Soog; Song, Kyung-Sik; Um, Yurry; Kim, Ok Tae; Lee, Yi; Hong, Chang Pyo; Shin, Dong-Ho; Kim, Chang-Kug; Lee, Seung-Eun; Ahn, Young-Sup; Lee, Dae-Young

    2015-11-09

    In this study, a method of metabolite profiling based on UPLC-QTOF/MS was developed to analyze Platycodon grandiflorum. In the optimal UPLC, various metabolites, including major platycosides, were separated well in 15 min. The metabolite extraction protocols were also optimized by selecting a solvent for use in the study, the ratio of solvent to sample and sonication time. This method was used to profile two different parts of P. grandiflorum, i.e., the roots of P. grandiflorum (PR) and the stems and leaves of P. grandiflorum (PS), in the positive and negative ion modes. As a result, PR and PS showed qualitatively and quantitatively different metabolite profiles. Furthermore, their metabolite compositions differed according to individual plant samples. These results indicate that the UPLC-QTOF/MS-based profiling method is a good tool to analyze various metabolites in P. grandiflorum. This metabolomics approach can also be applied to evaluate the overall quality of P. grandiflorum, as well as to discriminate the cultivars for the medicinal plant industry.

  2. Global Profiling of Various Metabolites in Platycodon grandiflorum by UPLC-QTOF/MS

    PubMed Central

    Lee, Jae Won; Ji, Seung-Heon; Kim, Geum-Soog; Song, Kyung-Sik; Um, Yurry; Kim, Ok Tae; Lee, Yi; Hong, Chang Pyo; Shin, Dong-Ho; Kim, Chang-Kug; Lee, Seung-Eun; Ahn, Young-Sup; Lee, Dae-Young

    2015-01-01

    In this study, a method of metabolite profiling based on UPLC-QTOF/MS was developed to analyze Platycodon grandiflorum. In the optimal UPLC, various metabolites, including major platycosides, were separated well in 15 min. The metabolite extraction protocols were also optimized by selecting a solvent for use in the study, the ratio of solvent to sample and sonication time. This method was used to profile two different parts of P. grandiflorum, i.e., the roots of P. grandiflorum (PR) and the stems and leaves of P. grandiflorum (PS), in the positive and negative ion modes. As a result, PR and PS showed qualitatively and quantitatively different metabolite profiles. Furthermore, their metabolite compositions differed according to individual plant samples. These results indicate that the UPLC-QTOF/MS-based profiling method is a good tool to analyze various metabolites in P. grandiflorum. This metabolomics approach can also be applied to evaluate the overall quality of P. grandiflorum, as well as to discriminate the cultivars for the medicinal plant industry. PMID:26569219

  3. Haplotype-based approach to known MS-associated regions increases the amount of explained risk

    PubMed Central

    Khankhanian, Pouya; Gourraud, Pierre-Antoine; Lizee, Antoine; Goodin, Douglas S

    2015-01-01

    Genome-wide association studies (GWAS), using single nucleotide polymorphisms (SNPs), have yielded 110 non-human leucocyte antigen genomic regions that are associated with multiple sclerosis (MS). Despite this large number of associations, however, only 28% of MS-heritability can currently be explained. Here we compare the use of multi-SNP-haplotypes to the use of single-SNPs as alternative methods to describe MS genetic risk. SNP-haplotypes (of various lengths from 1 up to 15 contiguous SNPs) were constructed at each of the 110 previously identified, MS-associated, genomic regions. Even after correcting for the larger number of statistical comparisons made when using the haplotype-method, in 32 of the regions, the SNP-haplotype based model was markedly more significant than the single-SNP based model. By contrast, in no region was the single-SNP based model similarly more significant than the SNP-haplotype based model. Moreover, when we included the 932 MS-associated SNP-haplotypes (that we identified from 102 regions) as independent variables into a logistic linear model, the amount of MS-heritability, as assessed by Nagelkerke's R-squared, was 38%, which was considerably better than 29%, which was obtained by using only single-SNPs. This study demonstrates that SNP-haplotypes can be used to fine-map the genetic associations within regions of interest previously identified by single-SNP GWAS. Moreover, the amount of the MS genetic risk explained by the SNP-haplotype associations in the 110 MS-associated genomic regions was considerably greater when using SNP-haplotypes than when using single-SNPs. Also, the use of SNP-haplotypes can lead to the discovery of new regions of interest, which have not been identified by a single-SNP GWAS. PMID:26185143

  4. Applications of DART-MS for food quality and safety assurance in food supply chain.

    PubMed

    Guo, Tianyang; Yong, Wei; Jin, Yong; Zhang, Liya; Liu, Jiahui; Wang, Sai; Chen, Qilong; Dong, Yiyang; Su, Haijia; Tan, Tianwei

    2017-03-01

    Direct analysis in real time (DART) represents a new generation of ion source which is used for rapid ionization of small molecules under ambient conditions. The combination of DART and various mass spectrometers allows analyzing multiple food samples with simple or no sample treatment, or in conjunction with prevailing protocolized sample preparation methods. Abundant applications by DART-MS have been reviewed in this paper. The DART-MS strategy applied to food supply chain (FSC), including production, processing, and storage and transportation, provides a comprehensive solution to various food components, contaminants, authenticity, and traceability. Additionally, typical applications available in food analysis by other ambient ionization mass spectrometers were summarized, and fundamentals mainly including mechanisms, devices, and parameters were discussed as well. © 2015 Wiley Periodicals, Inc. Mass Spec Rev. 36:161-187, 2017. © 2015 Wiley Periodicals, Inc.

  5. Analysis of haloacetic acids, bromate, and dalapon in natural waters by ion chromatography-tandem mass spectrometry.

    PubMed

    Wu, Shimin; Anumol, Tarun; Gandhi, Jay; Snyder, Shane A

    2017-03-03

    The addition of oxidants for disinfecting water can lead to the formation of potentially carcinogenic compounds referred to as disinfection byproducts (DBPs). Haloacetic acids (HAAs) are one of the most widely detected DBPs in US water utilities and some of them are regulated by the US Environmental Protection Agency (USEPA). The present study developed a method to analyze all the compounds in the USEPA method 557 (nine HAAs, bromate and dalapon) plus four potentially more toxic iodinated HAAs in water by coupling ion chromatography with tandem mass spectrometry (IC-MS/MS). This aqueous direct injection method has significant advantages over traditional GC methods, which require a derivatization and sample extraction that are laborious, time-consuming, and can negatively impact reproducibility. The method developed in this study requires half the time of the current USEPA method 557 on IC-MS/MS while including more compounds and achieving sub-μg/L level method detection limits (MDLs) for all 15 target analytes. The single laboratory lowest concentration minimum reporting level (LCMRL) has also been determined in reagent water, which ranged from 0.011 to 0.62μg/L for the analytes. The mean recoveries of the analytes during matrix spike recovery tests were 77-125% in finished drinking water and 81-112% in surface water. This method was then applied to untreated, chlorinated, and chloraminated groundwater and surface water samples. Bromate and 9 HAAs were detected at different levels in some of these samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Development of a sensitive and selective liquid chromatography-mass spectrometry method for high throughput analysis of paralytic shellfish toxins using graphitised carbon solid phase extraction.

    PubMed

    Boundy, Michael J; Selwood, Andrew I; Harwood, D Tim; McNabb, Paul S; Turner, Andrew D

    2015-03-27

    Routine regulatory monitoring of paralytic shellfish toxins (PST) commonly employs oxidative derivitisation and complex liquid chromatography fluorescence detection methods (LC-FL). The pre-column oxidation LC-FL method is currently implemented in New Zealand and the United Kingdom. When using this method positive samples are fractionated and two different oxidations are required to confirm the identity and quantity of each PST analogue present. There is a need for alternative methods that are simpler, provide faster turnaround times and have improved detection limits. Hydrophilic interaction liquid chromatography (HILIC) HPLC-MS/MS analysis of PST has been used for research purposes, but high detection limits and substantial sample matrix issues have prevented it from becoming a viable alternative for routine monitoring purposes. We have developed a HILIC UPLC-MS/MS method for paralytic shellfish toxins with an optimised desalting clean-up procedure on inexpensive carbon solid phase extraction cartridges for reduction of matrix interferences. This represents a major technical breakthrough and allows sensitive, selective and rapid analysis of paralytic shellfish toxins from a variety of sample types, including many commercially produced bivalve molluscan shellfish species. Additionally, this analytical approach avoids the need for complex calculations to determine sample toxicity, as unlike other methods each PST analogue is able to be quantified as a single resolved peak. This article presents the method development and optimisation information. A thorough single laboratory validation study has subsequently been performed and this data will be presented elsewhere. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Tracking emerging mycotoxins in food: development of an LC-MS/MS method for free and modified Alternaria toxins.

    PubMed

    Puntscher, Hannes; Kütt, Mary-Liis; Skrinjar, Philipp; Mikula, Hannes; Podlech, Joachim; Fröhlich, Johannes; Marko, Doris; Warth, Benedikt

    2018-05-16

    Mycotoxins produced by Alternaria fungi are ubiquitous food contaminants, but analytical methods for generating comprehensive exposure data are rare. We describe the development of an LC-MS/MS method covering 17 toxins for investigating the natural occurrence of free and modified Alternaria toxins in tomato sauce, sunflower seed oil, and wheat flour. Target analytes included alternariol (AOH), AOH-3-glucoside, AOH-9-glucoside, AOH-3-sulfate, alternariol monomethyl ether (AME), AME-3-glucoside, AME-3-sulfate, altenuene, isoaltenuene, tenuazonic acid (TeA), tentoxin (TEN), altertoxin I and II, alterperylenol, stemphyltoxin III, altenusin, and altenuic acid III. Extensive optimization resulted in a time- and cost-effective sample preparation protocol and a chromatographic baseline separation of included isomers. Overall, adequate limits of detection (0.03-9 ng/g) and quantitation (0.6-18 ng/g), intermediate precision (9-44%), and relative recovery values (75-100%) were achieved. However, stemphyltoxin III, AOH-3-sulfate, AME-3-sulfate, altenusin, and altenuic acid III showed recoveries in wheat flour below 70%, while their performance was stable and reproducible. Our pilot study with samples from the Austrian retail market demonstrated that tomato sauces (n = 12) contained AOH, AME, TeA, and TEN in concentrations up to 20, 4, 322, and 0.6 ng/g, while sunflower seed oil (n = 7) and wheat flour samples (n = 9) were contaminated at comparatively lower levels. Interestingly and of relevance for risk assessment, AOH-9-glucoside, discovered for the first time in naturally contaminated food items, and AME-3-sulfate were found in concentrations similar to their parent toxins. In conclusion, the established multi-analyte method proved to be fit for purpose for generating comprehensive Alternaria toxin occurrence data in different food matrices. Graphical abstract ᅟ.

  8. Optimization of quantitative proteomic analysis of clots generated from plasma of patients with venous thromboembolism.

    PubMed

    Stachowicz, Aneta; Siudut, Jakub; Suski, Maciej; Olszanecki, Rafał; Korbut, Ryszard; Undas, Anetta; Wiśniewski, Jacek R

    2017-01-01

    It is well known that fibrin network binds a large variety of proteins, including inhibitors and activators of fibrinolysis, which may affect clot properties, such as stability and susceptibility to fibrinolysis. Specific plasma clot composition differs between individuals and may change in disease states. However, the plasma clot proteome has not yet been in-depth analyzed, mainly due to technical difficulty related to the presence of a highly abundant protein-fibrinogen and fibrin that forms a plasma clot. The aim of our study was to optimize quantitative proteomic analysis of fibrin clots prepared ex vivo from citrated plasma of the peripheral blood drawn from patients with prior venous thromboembolism (VTE). We used a multiple enzyme digestion filter aided sample preparation, a multienzyme digestion (MED) FASP method combined with LC-MS/MS analysis performed on a Proxeon Easy-nLC System coupled to the Q Exactive HF mass spectrometer. We also evaluated the impact of peptide fractionation with pipet-tip strong anion exchange (SAX) method on the obtained results. Our proteomic approach revealed 476 proteins repeatedly identified in the plasma fibrin clots from patients with VTE including extracellular vesicle-derived proteins, lipoproteins, fibrinolysis inhibitors, and proteins involved in immune responses. The MED FASP method using three different enzymes: LysC, trypsin and chymotrypsin increased the number of identified peptides and proteins and their sequence coverage as compared to a single step digestion. Peptide fractionation with a pipet-tip strong anion exchange (SAX) protocol increased the depth of proteomic analyses, but also extended the time needed for sample analysis with LC-MS/MS. The MED FASP method combined with a label-free quantification is an excellent proteomic approach for the analysis of fibrin clots prepared ex vivo from citrated plasma of patients with prior VTE.

  9. Ultrahigh-performance liquid chromatography-ion trap mass spectrometry characterization of the steroidal saponins of Dioscorea panthaica Prain et Burkill and its application for accelerating the isolation and structural elucidation of steroidal saponins.

    PubMed

    Wang, Weihao; Zhao, Ye; Jing, Wenguang; Zhang, Jun; Xiao, Hui; Zha, Qin; Liu, An

    2015-03-01

    Dioscorea panthaica is a traditional Chinese medicinal herb used in the treatment of various physiological conditions, including cardiovascular disease, gastropathy and hypertension. Steroidal saponins (SS) are the main active ingredients of this herb and have effects on myocardial ischemia and cancer. The phytochemical evaluation of SS is both time-consuming and laborious, and the isolation and structural determination steps can be especially demanding. For this reason, the development of new methods to accelerate the processes involved in the identification, isolation and structural elucidation of SS is highly desirable. In this study, a new ultrahigh performance liquid chromatography-ion trap mass spectrometry (UHPLC-IT/MS(n)) method has been developed for the identification of the SS in D. panthaica Prain et Burkill. Notably, the current method can distinguish between spirostanol and furostanol-type compounds based on the fragmentation patterns observed by electrospray ionization-ion trap mass spectrometry (ESI-IT/MS(n)) analysis. UHPLC-IT/MS(n) was used to conduct a detailed investigation of the number, structural class and order of the sugar moieties in the sugar chains of the SS present in D. panthaica. The established fragmentation features were used to analyze the compounds found in the 65% ethanol fraction of the water extracts of D. panthaica. Twenty-three SS were identified, including 11 potential new compounds and six groups of isomers. Two of these newly identified SS were selected as representative examples, and their chemical structures were confirmed by (1)H and (13)C NMR analyses. This newly developed UHPLC-IT/MS(n) method therefore allowed for the efficient identification, isolation and structural determination of the SS in D. panthaica. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Analysis of Thiodiglycol: Validation of Semi-Volatile Analysis by HPLC-MS/MS by EPA Method MS777

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Owens, J; Koester, C

    The Environmental Protection Agency's (EPA) Region 5 Chicago Regional Laboratory (CRL) developed a method for the analysis of thiodiglycol, the breakdown product of the sulfur mustard HD, in water by high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS), titled Method EPA MS777 (hereafter referred to as EPA CRL SOP MS777). This draft standard operating procedure (SOP) was distributed to multiple EPA laboratories and to Lawrence Livermore National Laboratory, which was tasked to serve as a reference laboratory for EPA's Environmental Reference Laboratory Network (ERLN) and to develop and validate analytical procedures. The primary objective of this study was to verifymore » the analytical procedures described in MS777 for analysis of thiodiglycol in aqueous samples. The gathered data from this study will be used to: (1) demonstrate analytical method performance; (2) generate quality control acceptance criteria; and (3) revise the SOP to provide a validated method that would be available for use during a homeland security event. The data contained in this report will be compiled, by EPA CRL, with data generated by other EPA Regional laboratories so that performance metrics of Method EPA MS777 can be determined.« less

  11. The limitations on organic detection in Mars-like soils by thermal volatilization-gas chromatography-MS and their implications for the Viking results.

    PubMed

    Navarro-González, Rafael; Navarro, Karina F; de la Rosa, José; Iñiguez, Enrique; Molina, Paola; Miranda, Luis D; Morales, Pedro; Cienfuegos, Edith; Coll, Patrice; Raulin, François; Amils, Ricardo; McKay, Christopher P

    2006-10-31

    The failure of Viking Lander thermal volatilization (TV) (without or with thermal degradation)-gas chromatography (GC)-MS experiments to detect organics suggests chemical rather than biological interpretations for the reactivity of the martian soil. Here, we report that TV-GC-MS may be blind to low levels of organics on Mars. A comparison between TV-GC-MS and total organics has been conducted for a variety of Mars analog soils. In the Antarctic Dry Valleys and the Atacama and Libyan Deserts we find 10-90 mug of refractory or graphitic carbon per gram of soil, which would have been undetectable by the Viking TV-GC-MS. In iron-containing soils (jarosites from Rio Tinto and Panoche Valley) and the Mars simulant (palogonite), oxidation of the organic material to carbon dioxide (CO(2)) by iron oxides and/or their salts drastically attenuates the detection of organics. The release of 50-700 ppm of CO(2) by TV-GC-MS in the Viking analysis may indicate that an oxidation of organic material took place. Therefore, the martian surface could have several orders of magnitude more organics than the stated Viking detection limit. Because of the simplicity of sample handling, TV-GC-MS is still considered the standard method for organic detection on future Mars missions. We suggest that the design of future organic instruments for Mars should include other methods to be able to detect extinct and/or extant life.

  12. What Is in Your Wallet? Quantitation of Drugs of Abuse on Paper Currency with a Rapid LC-MS/MS Method

    ERIC Educational Resources Information Center

    Parker, Patrick D.; Beers, Brandon; Vergne, Matthew J.

    2017-01-01

    Laboratory experiments were developed to introduce students to the quantitation of drugs of abuse by high performance liquid chromatography-tandem mass spectrometry (LC-MS/MS). Undergraduate students were introduced to internal standard quantitation and the LC-MS/MS method optimization for cocaine. Cocaine extracted from paper currency was…

  13. Multi-residue determination of seventeen sulfonamides and five tetracyclines in fish tissue using a multi-stage LC-ESI-MS/MS approach based on advanced mass spectrometric techniques.

    PubMed

    Dasenaki, Marilena E; Thomaidis, Nikolaos S

    2010-07-05

    A strategy was newly developed to rapidly screen seventeen sulfonamides and five tetracyclines in a single run from fish tissues using ultra-high performance liquid chromatography (UHPLC) coupled with comprehensive mass spectrometric approaches, including precursor-ion scan and data dependent scan. The product ions for precursor-ion scanning were selected by studying the MS/MS fragmentation of the analytes. All sulfonamides share the same diagnostic product ion at m/z 156 in positive MS/MS scan, while for tetracycline antibiotics the diagnostic product ion was proved to be at m/z 153.8. Further characterization of each compound was performed using a data dependent scan. Separation was performed on a Zorbax Eclipse Plus C18 column with a gradient elution using acetonitrile - 0.1% formic acid mobile phase at a flow rate of 0.1 mL min(-1). This approach has proven to be a powerful, highly selective, and sensitive tool for rapid screening and detection of non-targeted components in fish tissue and requires a minimum sample preparation such as one generic extraction step with MeOH:ACN 50:50 (v/v) acidified with 0.05% formic acid. The method has also been applied successfully to porcine and poultry meat. The validation of such a screening method was performed for the first time according to Commission Decision 2002/657/EC and satisfactory method performance characteristics were achieved. Copyright 2010 Elsevier B.V. All rights reserved.

  14. Preparation of hair for measurement of elements by inductively coupled plasma-mass spectrometry (ICP-MS).

    PubMed

    Puchyr, R F; Bass, D A; Gajewski, R; Calvin, M; Marquardt, W; Urek, K; Druyan, M E; Quig, D

    1998-06-01

    The preparation of hair for the determination of elements is a critical component of the analysis procedure. Open-beaker, closed-vessel microwave, and flowthrough microwave digestion are methods that have been used for sample preparation and are discussed. A new digestion method for use with inductively coupled plasma-mass spectrometry (ICP-MS) has been developed. The method uses 0.2 g of hair and 3 mL of concentrated nitric acid in an atmospheric pressure-low-temperature microwave digestion (APLTMD) system. This preparation method is useful in handling a large numbers of samples per day and may be adapted to hair sample weights ranging from 0.08 to 0.3 g. After digestion, samples are analyzed by ICP-MS to determine the concentration of Li, Be, B, Na, Mg, Al, P, S, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, Ge, As, Se, Rb, Sr, Zr, Mo, Pd, Ag, Cd, Sn, Sb, I, Cs, Ba, Pt, Au, Hg, Tl, Pb, Bi, Th, and U. Benefits of the APLTMD include reduced contamination and sample handling, and increased precision, reliability, and sample throughput.

  15. Validation of AN Hplc-Dad Method for the Classification of Green Teas

    NASA Astrophysics Data System (ADS)

    Yu, Jingbo; Ye, Nengsheng; Gu, Xuexin; Liu, Ni

    A reversed phase high performance liquid chromatography (RP-HPLC) separation coupled with diode array detection (DAD) and electrospray ionization mass spectrometer (ESI/MS) was developed and optimized for the classification of green teas. Five catechins [epigallocatechin (EGC), epigallocatechin gallate (EGCG), epicatechin (EC), gallocatechin gallate (GCG), epicatechin gallate (ECG)] had been identified and quantified by the HPLC-DAD-ESI/MS/MS method. The limit of detection (LOD) of five catechins was within the range of 1.25-15 ng. All the analytes exhibited good linearity up to 2500 ng. These compounds were considered as chemical descriptors to define groups of green teas. Chemometric methods including principal component analysis (PCA) and hierarchical cluster analysis (HCA) were applied for the purpose. Twelve green tea samples originating from different regions were subjected to reveal the natural groups. The results showed that the analyzed green teas were differentiated mainly by provenance; HCA afforded an excellent performance in terms of recognition and prediction abilities. This method was accurate and reproducible, providing a potential approach for authentication of green teas.

  16. HPLC and LC-MS/MS methods for determination of sodium benzoate and potassium sorbate in food and beverages: performances of local accredited laboratories via proficiency tests in Turkey.

    PubMed

    Gören, Ahmet C; Bilsel, Gökhan; Şimşek, Adnan; Bilsel, Mine; Akçadağ, Fatma; Topal, Kevser; Ozgen, Hasan

    2015-05-15

    High Performance Liquid Chromatography LC-UV and LC-MS/MS methods were developed and validated for quantitative analyses of sodium benzoate and potassium sorbate in foods and beverages. HPLC-UV and LC-MS/MS methods were compared for quantitative analyses of sodium benzoate and potassium sorbate in a representative ketchup sample. Optimisation of the methods enabled the chromatographic separation of the analytes in less than 4 min. A correlation coefficient of 0.999 was achieved over the measured calibration range for both compounds and methods (HPLC and LC-MS/MS). The uncertainty values of sodium benzoate and potassium sorbate were found as 0.199 and 0.150 mg/L by HPLC and 0.072 and 0.044 mg/L by LC-MS/MS, respectively. Proficiency testing performance of Turkish accredited laboratories between the years 2005 and 2013 was evaluated and reported herein. The aim of the proficiency testing scheme was to evaluate the performance of the laboratories, analysing benzoate and sorbate in tomato ketchup. Copyright © 2014 Elsevier Ltd. All rights reserved.

  17. An Optimized Informatics Pipeline for Mass Spectrometry-Based Peptidomics

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wu, Chaochao; Monroe, Matthew E.; Xu, Zhe

    2015-12-26

    Comprehensive MS analysis of peptidome, the intracellular and intercellular products of protein degradation, has the potential to provide novel insights on endogenous proteolytic processing and their utility in disease diagnosis and prognosis. Along with the advances in MS instrumentation, a plethora of proteomics data analysis tools have been applied for direct use in peptidomics; however an evaluation of the currently available informatics pipelines for peptidomics data analysis has yet to be reported. In this study, we set off by evaluating the results of several popular MS/MS database search engines including MS-GF+, SEQUEST and MS-Align+ for peptidomics data analysis, followed bymore » identification and label-free quantification using the well-established accurate mass and time (AMT) tag and newly developed informed quantification (IQ) approaches, both based on direct LC-MS analysis. Our result demonstrated that MS-GF+ outperformed both SEQUEST and MS-Align+ in identifying peptidome peptides. Using a database established from the MS-GF+ peptide identifications, both the AMT tag and IQ approaches provided significantly deeper peptidome coverage and less missing value for each individual data set than the MS/MS methods, while achieving robust label-free quantification. Besides having an excellent correlation with the AMT tag quantification results, IQ also provided slightly higher peptidome coverage than AMT. Taken together, we propose an optimal informatics pipeline combining MS-GF+ for initial database searching with IQ (or AMT) for identification and label-free quantification for high-throughput, comprehensive and quantitative peptidomics analysis.« less

  18. Ultra high performance liquid chromatography tandem mass spectrometry for rapid analysis of trace organic contaminants in water

    PubMed Central

    2013-01-01

    Background The widespread utilization of organic compounds in modern society and their dispersion through wastewater have resulted in extensive contamination of source and drinking waters. The vast majority of these compounds are not regulated in wastewater outfalls or in drinking water while trace amounts of certain compounds can impact aquatic wildlife. Hence it is prudent to monitor these contaminants in water sources until sufficient toxicological data relevant to humans becomes available. A method was developed for the analysis of 36 trace organic contaminants (TOrCs) including pharmaceuticals, pesticides, steroid hormones (androgens, progestins, and glucocorticoids), personal care products and polyfluorinated compounds (PFCs) using a single solid phase extraction (SPE) technique with ultra-high performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS). The method was applied to a variety of water matrices to demonstrate method performance and reliability. Results UHPLC-MS/MS in both positive and negative electrospray ionization (ESI) modes was employed to achieve optimum sensitivity while reducing sample analysis time (<20 min) compared with previously published methods. The detection limits for most compounds was lower than 1.0 picogram on the column while reporting limits in water ranged from 0.1 to 15 ng/L based on the extraction of a 1 L sample and concentration to 1 mL. Recoveries in ultrapure water for most compounds were between 90-110%, while recoveries in surface water and wastewater were in the range of 39-121% and 38-141% respectively. The analytical method was successfully applied to analyze samples across several different water matrices including wastewater, groundwater, surface water and drinking water at different stages of the treatment. Among several compounds detected in wastewater, sucralose and TCPP showed the highest concentrations. Conclusion The proposed method is sensitive, rapid and robust; hence it can be used to analyze a large variety of trace organic compounds in different water matrixes. PMID:23777604

  19. Development and validation of the simultaneous measurement of four vitamin D metabolites in serum by LC-MS/MS for clinical laboratory applications.

    PubMed

    Satoh, Mamoru; Ishige, Takayuki; Ogawa, Shoujiro; Nishimura, Motoi; Matsushita, Kazuyuki; Higashi, Tatsuya; Nomura, Fumio

    2016-11-01

    The quantification of serum 25-hydroxyvitamin D [25(OH)D] as an indicator of vitamin D status is currently primarily conducted by immunoassays, yet LC-MS/MS would allow more accurate determination. Furthermore, LC-MS/MS would allow simultaneous measurement of multiple analytes. The aim of this study was to develop and validate an LC-MS/MS method to simultaneously measure four vitamin D metabolites (25(OH)D 3 , 3-epi-25(OH)D 3 , 25(OH)D 2 , and 24,25(OH) 2 D 3 ) in serum for clinical laboratory applications. Serum samples were first prepared in a 96-well supported liquid extraction plate and the eluate was derivatized using the Cookson-type reagent 4-(4'-dimethylaminophenyl)-1,2,4-triazoline-3,5-dione (DAPTAD), which rapidly and quantitatively reacts with the s-cis-diene structure of vitamin D metabolites. The derivatized samples were subjected to LC-MS/MS, ionized by electrospray ionization (positive-ion mode), and detected by selected reaction monitoring. The lower limits of quantification for 25(OH)D 3 , 3-epi-25(OH)D 3 , 25(OH)D 2 , and 24,25(OH) 2 D 3 were 0.091, 0.020, 0.013, and 0.024 ng/mL, respectively. The accuracy values and the extraction recoveries for these four metabolites were satisfactory. Serum 25(OH)D levels determined by our LC-MS/MS were compared with those obtained by conventional radioimmunoassay (RIA) that cannot distinguish 25(OH)D 3 and 25(OH)D 2 . The values obtained by the RIA method exhibited a mean bias of about 8.35 ng/mL, most likely as a result of cross reaction of the antibody with low-abundance metabolites, including 24,25(OH) 2 D 3 . Various preanalytical factors, such as long sample sitting prior to serum separation, repeated freeze-thaw cycles, and the presence of anticoagulants, had no significant effects on these determinations. This high-throughput LC-MS/MS simultaneous assay of the four vitamin D metabolites 25(OH)D 3 , 3-epi-25(OH)D 3 , 25(OH)D 2 , and 24,25(OH) 2 D 3 required as little as 20 μL serum. This method will aid further understanding of low-abundance vitamin D metabolites, as well as the accurate determination of 25(OH)D 3 and 25(OH)D 2 .

  20. Cost of Illness of Multiple Sclerosis - A Systematic Review

    PubMed Central

    Ernstsson, Olivia; Gyllensten, Hanna; Alexanderson, Kristina; Tinghög, Petter; Friberg, Emilie; Norlund, Anders

    2016-01-01

    Background Cost-of-illness (COI) studies of Multiple Sclerosis (MS) are vital components for describing the economic burden of MS, and are frequently used in model studies of interventions of MS. We conducted a systematic review of studies estimating the COI of MS, to compare costs between studies and examine cost drivers, emphasizing generalizability and methodological choices. Material and method A literature search on studies published in English on COI of MS was performed in PubMed for the period January 1969 to January 2014, resulting in 1,326 publications. A mapping of studies using a bottom-up approach or top-down approach, respectively, was conducted for the 48 studies assessed as relevant. In a second analysis, the cost estimates were compared between the 29 studies that used a societal perspective on costs, human capital approach for indirect costs, presenting number of patients included, time-period studied, and year of price level used. Results The mapping showed that bottom-up studies and prevalence approaches were most common. The cost ratios between different severity levels within studies were relatively stable, to the ratio of 1 to 2 to 3 for disability level categories. Drugs were the main cost drivers for MS-patients with low disease severity, representing 29% to 82% of all costs in this patient group, while the main cost components for groups with more advanced MS symptoms were production losses due to MS and informal care, together representing 17% to 67% of costs in those groups. Conclusion The bottom-up method and prevalence approach dominated in studies of COI of MS. Our findings show that there are difficulties in comparing absolute costs across studies, nevertheless, the relative costs expressed as cost ratios, comparing different severity levels, showed higher resemblance. Costs of drugs were main cost drivers for less severe MS and informal care and production losses for the most severe MS. PMID:27411042

  1. Application of LC/MS/MS Techniques to Development of US EPA Standardized Methods for Chemicals of Emerging Concern

    EPA Science Inventory

    This presentation will describe the U.S. EPA’s drinking water and ambient water method development program in relation to the process employed and the typical challenges encountered in developing standardized LC/MS/MS methods for chemicals of emerging concern. The EPA&rsquo...

  2. Simultaneous determination of five coumarins in Angelicae dahuricae Radix by HPLC/UV and LC-ESI-MS/MS.

    PubMed

    Park, Ah Yeon; Park, So-Young; Lee, Jaehyun; Jung, Mihye; Kim, Jinwoong; Kang, Sam Sik; Youm, Jeong-Rok; Han, Sang Beom

    2009-10-01

    Rapid, simple and reliable HPLC/UV and LC-ESI-MS/MS methods for the simultaneous determination of five active coumarins of Angelicae dahuricae Radix, byakangelicol (1), oxypeucedanin (2), imperatorin (3), phellopterin (4) and isoimperatorin (5) were developed and validated. The separation condition for HPLC/UV was optimized using a Develosil RPAQUEOUS C(30) column using 70% acetonitrile in water as the mobile phase. This HPLC/UV method was successful for providing the baseline separation of the five coumarins with no interfering peaks detected in the 70% ethanol extract of Angelicae dahuricae Radix. The specific determination of the five coumarins was also accomplished by a triple quadrupole tandem mass spectrometer equipped with an electrospray ionization source (LC-ESI-MS/MS). Multiple reaction monitoring (MRM) in the positive mode was used to enhance the selectivity of detection. The LC-ESI-MS/MS methods were successfully applied for the determination of the five major coumarins in Angelicae dahuricae Radix. These HPLC/UV and LC-ESI-MS/MS methods were validated in terms of recovery, linearity, accuracy and precision (intra- and inter-day validation). Taken together, the shorter analysis time involved makes these HPLC/UV and LC-ESI-MS/MS methods valuable for the commercial quality control of Angelicae dahuricae Radix extracts and its pharmaceutical preparations. Copyright (c) 2009 John Wiley & Sons, Ltd.

  3. Rapid screening of N-oxides of chemical warfare agents degradation products by ESI-tandem mass spectrometry.

    PubMed

    Sridhar, L; Karthikraj, R; Lakshmi, V V S; Raju, N Prasada; Prabhakar, S

    2014-08-01

    Rapid detection and identification of chemical warfare agents and related precursors/degradation products in various environmental matrices is of paramount importance for verification of standards set by the chemical weapons convention (CWC). Nitrogen mustards, N,N-dialkylaminoethyl-2-chlorides, N,N-dialkylaminoethanols, N-alkyldiethanolamines, and triethanolamine, which are listed CWC scheduled chemicals, are prone to undergo N-oxidation in environmental matrices or during decontamination process. Thus, screening of the oxidized products of these compounds is also an important task in the verification process because the presence of these products reveals alleged use of nitrogen mustards or precursors of VX compounds. The N-oxides of aminoethanols and aminoethylchlorides easily produce [M + H](+) ions under electrospray ionization conditions, and their collision-induced dissociation spectra include a specific neutral loss of 48 u (OH + CH2OH) and 66 u (OH + CH2Cl), respectively. Based on this specific fragmentation, a rapid screening method was developed for screening of the N-oxides by applying neutral loss scan technique. The method was validated and the applicability of the method was demonstrated by analyzing positive and negative samples. The method was useful in the detection of N-oxides of aminoethanols and aminoethylchlorides in environmental matrices at trace levels (LOD, up to 500 ppb), even in the presence of complex masking agents, without the use of time-consuming sample preparation methods and chromatographic steps. This method is advantageous for the off-site verification program and also for participation in official proficiency tests conducted by the Organization for the Prohibition of Chemical Weapons (OPCW), the Netherlands. The structure of N-oxides can be confirmed by the MS/MS experiments on the detected peaks. A liquid chromatography-mass spectrometry (LC-MS) method was developed for the separation of isomeric N-oxides of aminoethanols and aminoethylchlorides using a C18 Hilic column. Critical isomeric compounds can be confirmed by LC-MS/MS experiments, after detecting the N-oxides from the neutral loss scanning method.

  4. Dietary Interventions in Multiple Sclerosis: Development and Pilot-Testing of an Evidence Based Patient Education Program

    PubMed Central

    Riemann-Lorenz, Karin; Eilers, Marlene; von Geldern, Gloria; Schulz, Karl-Heinz; Köpke, Sascha; Heesen, Christoph

    2016-01-01

    Background Dietary factors have been discussed to influence risk or disease course of multiple sclerosis (MS). Specific diets are widely used among patients with MS. Objective To design and pilot-test an evidence based patient education program on dietary factors in MS. Methods We performed a systematic literature search on the effectiveness of dietary interventions in MS. A web-based survey among 337 patients with MS and 136 healthy controls assessed knowledge, dietary habits and information needs. An interactive group education program was developed and pilot-tested. Results Fifteen randomised-controlled trials (RCTs) were included in the systematic review. Quality of evidence was low and no clear benefit could be seen. Patients with MS significantly more often adhered to a `Mediterranean Diet`(29.7% versus 14.0%, p<0.001) compared to controls. 143 (42%) of the patients with MS had tried special MS diets. Important information needs addressed effectiveness of MS diets (44%) and relation between nutrition and MS (43%). A pilot test of our newly developed patient education program with 13 participants showed excellent comprehensibility and the MS-specific content was judged as very important. However, the poor evidence base for dietary approaches in MS was perceived disappointing. Conclusions Development and pilot-testing of an evidence-based patient education program on nutrition and MS is feasible. Patient satisfaction with the program suffers from the lack of evidence. Further research should focus on generating evidence for the potential influence of lifestyle habits (diet, physical activity) on MS disease course thus meeting the needs of patients with MS. PMID:27764237

  5. Early Changes in Atrial Electromechanical Coupling in Patients with Hypertension: Assessment by Tissue Doppler Imaging

    PubMed Central

    Avci, Burcak Kilickiran; Gulmez, Oyku; Donmez, Guclu; Pehlivanoglu, Seckin

    2016-01-01

    Background: Hypertension (HT) is associated with atrial electrophysiological abnormalities. Echocardiographic pulsed wave tissue Doppler imaging (TDI) is one of the noninvasive methods for evaluation of atrial electromechanical properties. The aims of our study were to investigate the early changes in atrial electromechanical conduction in patients with HT and to assess the parameters that affect atrial electromechanical conduction. Methods: Seventy-six patients with HT (41 males, mean age 52.6 ± 9.0 years) and 41 controls (22 males, mean age 49.8 ± 7.9 years) were included in the study. Atrial electromechanical coupling at the right (PRA), left (PLA), interatrial septum (PIS) were measured with TDI. Intra- (right: PIS-PRA, left: PLA-PIS) and inter-atrial (PLA-PRA) electromechanical delays were calculated. Maximum P-wave duration (Pmax) was calculated from 12-lead electrocardiogram. Results: Atrial electromechanical coupling at PLA (76.6 ± 14.1 ms vs. 82.9 ± 15.8 ms, P = 0.036), left intra-atrial (10.9 ± 5.0 ms vs. 14.0 ± 9.7 ms, P = 0.023), right intra-atrial (10.6 ± 7.8 ms vs. 14.5 ± 10.1 ms, P = 0.035), and interatrial electromechanical (21.4 ± 9.8 ms vs. 28.3 ± 12.7 ms, P = 0.003) delays were significantly longer in patients with HT. The linear regression analysis showed that left ventricular (LV) mass index and Pmax were significantly associated with PLA (P = 0.001 and P = 0.002, respectively), and the LV mass index was the only related factor for interatrial delay (P = 0.001). Conclusions: Intra- and interatrial electromechanical delay, PLA were significantly prolonged in hypertensive patients. LV mass index and Pmax were significantly associated with PLA, and the LV mass index was the only related factor for interatrial delay. The atrial TDI can be a valuable method to assess the early changes of atrial electromechanical conduction properties in those patients. PMID:27231168

  6. Looking into aqueous humor through metabolomics spectacles - exploring its metabolic characteristics in relation to myopia.

    PubMed

    Barbas-Bernardos, Cecilia; Armitage, Emily G; García, Antonia; Mérida, Salvador; Navea, Amparo; Bosch-Morell, Francisco; Barbas, Coral

    2016-08-05

    Aqueous humor is the transparent fluid found in the anterior chamber of the eye that provides the metabolic requirements to the avascular tissues surrounding it. Despite the fact that metabolomics could be a powerful tool in the characterization of this biofluid and in revealing metabolic signatures of common ocular diseases such as myopia, it has never to our knowledge previously been applied in humans. In this research a novel method for the analysis of aqueous humor is presented to show its application in the characterization of this biofluid using CE-MS. The method was extended to a dual platform method (CE-MS and LC-MS) in order to compare samples from patients with different severities of myopia in order to explore the disease from the metabolic phenotype point of view. With this method, a profound knowledge of the metabolites present in human aqueous humor has been obtained: over 40 metabolites were reproducibly and simultaneously identified from a low volume of sample by CE-MS, including among others, a vast number of amino acids and derivatives. When this method was extended to study groups of patients with high or low myopia in both CE-MS and LC-MS, it has been possible to identify over 20 significantly different metabolite and lipid signatures that distinguish patients based on the severity of myopia. Among these, the most notable higher abundant metabolites in high myopia were aminooctanoic acid, arginine, citrulline and sphinganine while features of low myopia were aminoundecanoic acid, dihydro-retinoic acid and cysteinylglycine disulfide. This dual platform approach offered complementarity such that different metabolites were detected in each technique. Together the experiments presented provide a whelm of valuable information about human aqueous humor and myopia, proving the utility of non-targeted metabolomics for the first time in analyzing this type of sample and the metabolic phenotype of this disease. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Automated Mini-Column Solid-Phase Extraction Cleanup for High-Throughput Analysis of Chemical Contaminants in Foods by Low-Pressure Gas Chromatography-Tandem Mass Spectrometry.

    PubMed

    Lehotay, Steven J; Han, Lijun; Sapozhnikova, Yelena

    2016-01-01

    This study demonstrated the application of an automated high-throughput mini-cartridge solid-phase extraction (mini-SPE) cleanup for the rapid low-pressure gas chromatography-tandem mass spectrometry (LPGC-MS/MS) analysis of pesticides and environmental contaminants in QuEChERS extracts of foods. Cleanup efficiencies and breakthrough volumes using different mini-SPE sorbents were compared using avocado, salmon, pork loin, and kale as representative matrices. Optimum extract load volume was 300 µL for the 45 mg mini-cartridges containing 20/12/12/1 (w/w/w/w) anh. MgSO 4 /PSA (primary secondary amine)/C 18 /CarbonX sorbents used in the final method. In method validation to demonstrate high-throughput capabilities and performance results, 230 spiked extracts of 10 different foods (apple, kiwi, carrot, kale, orange, black olive, wheat grain, dried basil, pork, and salmon) underwent automated mini-SPE cleanup and analysis over the course of 5 days. In all, 325 analyses for 54 pesticides and 43 environmental contaminants (3 analyzed together) were conducted using the 10 min LPGC-MS/MS method without changing the liner or retuning the instrument. Merely, 1 mg equivalent sample injected achieved <5 ng g -1 limits of quantification. With the use of internal standards, method validation results showed that 91 of the 94 analytes including pairs achieved satisfactory results (70-120 % recovery and RSD ≤ 25 %) in the 10 tested food matrices ( n  = 160). Matrix effects were typically less than ±20 %, mainly due to the use of analyte protectants, and minimal human review of software data processing was needed due to summation function integration of analyte peaks. This study demonstrated that the automated mini-SPE + LPGC-MS/MS method yielded accurate results in rugged, high-throughput operations with minimal labor and data review.

  8. ANALYSIS OF RICIN TOXIN PREPARATIONS FOR CARBOHYDRATE AND FATTY ACID ABUNDANCE AND ISOTOPE RATIO INFORMATION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wunschel, David S.; Kreuzer-Martin, Helen W.; Antolick, Kathryn C.

    2009-12-01

    This report describes method development and preliminary evaluation for analyzing castor samples for signatures of purifying ricin. Ricin purification from the source castor seeds is essentially a problem of protein purification using common biochemical methods. Indications of protein purification will likely manifest themselves as removal of the non-protein fractions of the seed. Two major, non-protein, types of biochemical constituents in the seed are the castor oil and various carbohydrates. The oil comprises roughly half the seed weight while the carbohydrate component comprises roughly half of the remaining “mash” left after oil and hull removal. Different castor oil and carbohydrate componentsmore » can serve as indicators of specific toxin processing steps. Ricinoleic acid is a relatively unique fatty acid in nature and is the most abundant component of castor oil. The loss of ricinoleic acid indicates a step to remove oil from the seeds. The relative amounts of carbohydrates and carbohydrate-like compounds, including arabinose, xylose, myo-inositol fucose, rhamnose, glucosamine and mannose detected in the sample can also indicate specific processing steps. For instance, the differential loss of arabinose relative to mannose and N-acetyl glucosamine indicates enrichment for the protein fraction of the seed using protein precipitation. The methods developed in this project center on fatty acid and carbohydrate extraction from castor samples followed by derivatization to permit analysis by gas chromatography-mass spectrometry (GC-MS). Method descriptions herein include: the source and preparation of castor materials used for method evaluation, the equipment and description of procedure required for chemical derivatization, and the instrument parameters used in the analysis. Two types of derivatization methods describe analysis of carbohydrates and one procedure for analysis of fatty acids. Two types of GC-MS analysis is included in the method development, one employing a quadrupole MS system for compound identification and an isotope ratio MS for measuring the stable isotope ratios of deuterium and hydrogen (D/H) in fatty acids. Finally, the method for analyzing the compound abundance data is included. This study indicates that removal of ricinoleic acid is a conserved consequence of each processing step we tested. Furthermore, the stable isotope D/H ratio of ricinoleic acid distinguished between two of the three castor seed sources. Concentrations of arabinose, xylose, mannose, glucosamine and myo-inositol differentiated between crude or acetone extracted samples and samples produced by protein precipitation. Taken together these data illustrate the ability to distinguish between processes used to purify a ricin sample as well as potentially the source seeds.« less

  9. The Effects of Aerobic Exercise on the Recovery of Walking Ability and Neuroplasticity in People with Multiple Sclerosis: A Systematic Review of Animal and Clinical Studies

    PubMed Central

    2017-01-01

    Introduction Walking is of high priority for people with multiple sclerosis (PwMS). It remains unclear whether aerobic exercise can improve walking ability and upregulate neurotrophins. This review aims to consolidate evidence to develop optimal aerobic training parameters to enhance walking outcomes and neuroplasticity in PwMS. Methods Clinical studies examining aerobic exercise for ≥3 weeks, having outcomes on walking with or without neurotrophic markers, were included. Studies utilizing animal models of MS were included if they employed aerobic exercise with outcomes on neurological recovery and neurotrophins. From a total of 1783 articles, 12 clinical and 5 animal studies were included. Results Eleven clinical studies reported improvements in walking ability. Only two clinical studies evaluated both walking and neurotrophins, and neither found an increase in neurotrophins despite improvements in walking. Patients with significant walking impairments were underrepresented. Long-term follow-up revealed mixed results. Two animal studies reported a positive change in both neurological recovery and neurotrophins. Conclusion Aerobic exercise improves walking ability in PwMS. Gains are not consistently maintained at 2- to 9-month follow-up. Studies examining levels of neurotrophins are inconclusive, necessitating further research. Aerobic exercise enhances both neurological recovery and neurotrophins in animal studies when started 2 weeks before induction of MS. PMID:29181199

  10. Determination of dabigatran, rivaroxaban and apixaban by ultra-performance liquid chromatography - tandem mass spectrometry (UPLC-MS/MS) and coagulation assays for therapy monitoring of novel direct oral anticoagulants.

    PubMed

    Schmitz, E M H; Boonen, K; van den Heuvel, D J A; van Dongen, J L J; Schellings, M W M; Emmen, J M A; van der Graaf, F; Brunsveld, L; van de Kerkhof, D

    2014-10-01

    Three novel direct oral anticoagulants (DOACs) have recently been registered by the Food and Drug Administration and European Medicines Agency Commission: dabigatran, rivaroxaban, and apixaban. To quantify DOACs in plasma, various dedicated coagulation assays have been developed. To develop and validate a reference ultra-performance liquid chromatography - tandem mass spectrometry (UPLC-MS/MS) method and to evaluate the analytical performance of several coagulation assays for quantification of dabigatran, rivaroxaban, and apixaban. The developed UPLC-MS/MS method was validated by determination of precision, accuracy, specificity, matrix effects, lower limits of detection, carry-over, recovery, stability, and robustness. The following coagulation assays were evaluated for accuracy and precision: laboratory-developed (LD) diluted thrombin time (dTT), Hemoclot dTT, Pefakit PiCT, ECA, Liquid anti-Xa, Biophen Heparin (LRT), and Biophen DiXal anti-Xa. Agreement between the various coagulation assays and UPLC-MS/MS was determined with random samples from patients using dabigatran or rivaroxaban. The UPLC-MS/MS method was shown to be accurate, precise, sensitive, stable, and robust. The dabigatran coagulation assay showing the best precision, accuracy and agreement with the UPLC-MS/MS method was the LD dTT test. For rivaroxaban, the anti-factor Xa assays were superior to the PiCT-Xa assay with regard to precision, accuracy, and agreement with the reference method. For apixaban, the Liquid anti-Xa assay was superior to the PiCT-Xa assay. Statistically significant differences were observed between the various coagulation assays as compared with the UPLC-MS/MS reference method. It is currently unknown whether these differences are clinically relevant. When DOACs are quantified with coagulation assays, comparison with a reference method as part of proficiency testing is therefore pivotal. © 2014 International Society on Thrombosis and Haemostasis.

  11. Insights from native mass spectrometry approaches for top- and middle- level characterization of site-specific antibody-drug conjugates

    PubMed Central

    Botzanowski, Thomas; Erb, Stéphane; Hernandez-Alba, Oscar; Ehkirch, Anthony; Colas, Olivier; Wagner-Rousset, Elsa; Rabuka, David; Beck, Alain; Drake, Penelope M.; Cianférani, Sarah

    2017-01-01

    ABSTRACT Antibody-drug conjugates (ADCs) have emerged as a family of compounds with promise as efficient immunotherapies. First-generation ADCs were generated mostly via reactions on either lysine side-chain amines or cysteine thiol groups after reduction of the interchain disulfide bonds, resulting in heterogeneous populations with a variable number of drug loads per antibody. To control the position and the number of drug loads, new conjugation strategies aiming at the generation of more homogeneous site-specific conjugates have been developed. We report here the first multi-level characterization of a site-specific ADC by state-of-the-art mass spectrometry (MS) methods, including native MS and its hyphenation to ion mobility (IM-MS). We demonstrate the versatility of native MS methodologies for site-specific ADC analysis, with the unique ability to provide several critical quality attributes within one single run, along with a direct snapshot of ADC homogeneity/heterogeneity without extensive data interpretation. The capabilities of native IM-MS to directly access site-specific ADC conformational information are also highlighted. Finally, the potential of these techniques for assessing an ADC's heterogeneity/homogeneity is illustrated by comparing the analytical characterization of a site-specific DAR4 ADC to that of first-generation ADCs. Altogether, our results highlight the compatibility, versatility, and benefits of native MS approaches for the analytical characterization of all types of ADCs, including site-specific conjugates. Thus, we envision integrating native MS and IM-MS approaches, even in their latest state-of-the-art forms, into workflows that benchmark bioconjugation strategies. PMID:28406343

  12. Determination of rivaroxaban in patient's plasma samples by anti-Xa chromogenic test associated to High Performance Liquid Chromatography tandem Mass Spectrometry (HPLC-MS/MS).

    PubMed

    Derogis, Priscilla Bento Matos; Sanches, Livia Rentas; de Aranda, Valdir Fernandes; Colombini, Marjorie Paris; Mangueira, Cristóvão Luis Pitangueira; Katz, Marcelo; Faulhaber, Adriana Caschera Leme; Mendes, Claudio Ernesto Albers; Ferreira, Carlos Eduardo Dos Santos; França, Carolina Nunes; Guerra, João Carlos de Campos

    2017-01-01

    Rivaroxaban is an oral direct factor Xa inhibitor, therapeutically indicated in the treatment of thromboembolic diseases. As other new oral anticoagulants, routine monitoring of rivaroxaban is not necessary, but important in some clinical circumstances. In our study a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was validated to measure rivaroxaban plasmatic concentration. Our method used a simple sample preparation, protein precipitation, and a fast chromatographic run. It was developed a precise and accurate method, with a linear range from 2 to 500 ng/mL, and a lower limit of quantification of 4 pg on column. The new method was compared to a reference method (anti-factor Xa activity) and both presented a good correlation (r = 0.98, p < 0.001). In addition, we validated hemolytic, icteric or lipemic plasma samples for rivaroxaban measurement by HPLC-MS/MS without interferences. The chromogenic and HPLC-MS/MS methods were highly correlated and should be used as clinical tools for drug monitoring. The method was applied successfully in a group of 49 real-life patients, which allowed an accurate determination of rivaroxaban in peak and trough levels.

  13. Analysis of Ethanolamines: Validation of Semi-Volatile Analysis by HPLC-MS/MS by EPA Method MS888

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Owens, J; Vu, A; Koester, C

    The Environmental Protection Agency's (EPA) Region 5 Chicago Regional Laboratory (CRL) developed a method titled 'Analysis of Diethanolamine, Triethanolamine, n-Methyldiethanolamine, and n-Ethyldiethanolamine in Water by Single Reaction Monitoring Liquid Chromatography/Tandem Mass Spectrometry (LC/MS/MS): EPA Method MS888'. This draft standard operating procedure (SOP) was distributed to multiple EPA laboratories and to Lawrence Livermore National Laboratory, which was tasked to serve as a reference laboratory for EPA's Environmental Reference Laboratory Network (ERLN) and to develop and validate analytical procedures. The primary objective of this study was to validate and verify the analytical procedures described in 'EPA Method MS888' for analysis of themore » listed ethanolamines in aqueous samples. The gathered data from this validation study will be used to: (1) demonstrate analytical method performance; (2) generate quality control acceptance criteria; and (3) revise the SOP to provide a validated method that would be available for use during a homeland security event. The data contained in this report will be compiled, by EPA CRL, with data generated by other EPA Regional laboratories so that performance metrics of 'EPA Method MS888' can be determined.« less

  14. Tackling saponin diversity in marine animals by mass spectrometry: data acquisition and integration.

    PubMed

    Decroo, Corentin; Colson, Emmanuel; Demeyer, Marie; Lemaur, Vincent; Caulier, Guillaume; Eeckhaut, Igor; Cornil, Jérôme; Flammang, Patrick; Gerbaux, Pascal

    2017-05-01

    Saponin analysis by mass spectrometry methods is nowadays progressively supplementing other analytical methods such as nuclear magnetic resonance (NMR). Indeed, saponin extracts from plant or marine animals are often constituted by a complex mixture of (slightly) different saponin molecules that requires extensive purification and separation steps to meet the requirement for NMR spectroscopy measurements. Based on its intrinsic features, mass spectrometry represents an inescapable tool to access the structures of saponins within extracts by using LC-MS, MALDI-MS, and tandem mass spectrometry experiments. The combination of different MS methods nowadays allows for a nice description of saponin structures, without extensive purification. However, the structural characterization process is based on low kinetic energy CID which cannot afford a total structure elucidation as far as stereochemistry is concerned. Moreover, the structural difference between saponins in a same extract is often so small that coelution upon LC-MS analysis is unavoidable, rendering the isomeric distinction and characterization by CID challenging or impossible. In the present paper, we introduce ion mobility in combination with liquid chromatography to better tackle the structural complexity of saponin congeners. When analyzing saponin extracts with MS-based methods, handling the data remains problematic for the comprehensive report of the results, but also for their efficient comparison. We here introduce an original schematic representation using sector diagrams that are constructed from mass spectrometry data. We strongly believe that the proposed data integration could be useful for data interpretation since it allows for a direct and fast comparison, both in terms of composition and relative proportion of the saponin contents in different extracts. Graphical Abstract A combination of state-of-the-art mass spectrometry methods, including ion mobility spectroscopy, is developed to afford a complete description of the saponin molecules in natural extracts.

  15. Amnesic shellfish poisoning toxins in shellfish: estimation of uncertainty of measurement for a liquid chromatography/tandem mass spectrometry method.

    PubMed

    Holland, Patrick T; McNabb, Paul; Selwood, Andrew I; Neil, Tracey

    2003-01-01

    A liquid chromatography/mass spectrometry (LC/MS) method for amnesic shellfish poisoning toxins in shellfish was developed and validated. Tissue homogenate (4 g) was extracted with 16 mL methanol-water (1 + 1, v/v). Dilution into acetonitrile-water (1 + 9, v/v) was followed by C18 solid-phase extraction cleanup. Domoic acid (DA) and epi-domoic acid were determined by LC/MS/MS with electrospray ionization and multiple reaction monitoring. External calibration was performed with dilutions of a certified reference standard. Advantages of this method include speed, lower detection limits, and a very high degree of specificity. The LC/MS response was highly linear, and there were no significant interferences to the determination of DA. Formal method validation was performed on 4 shellfish species. Fortification studies gave recoveries (mean +/- SD; n = 24) of 93 +/- 14% at 1 mg/kg, and 93.3 +/- 7.6% at 20 mg/kg over all the species. Analysis of a mussel certified reference material showed the bias as < 5%. The limits of detection and quantitation were 0.15 and 0.5 mg/kg, respectively. Routine application of the method over 4 months gave a recovery for the QC sample (1 mg/kg fortified blank mussel homogenate) run with each batch of 88.9 +/- 5.5% (mean +/- SD; n = 37). The total uncertainty of measurement results were estimated as 0.12 (12%) at 0.25-5 mg/kg and 0.079 (7.9%) at 5-50 mg/kg. The major contribution to the uncertainty was the repeatability of the LC/MS determination, probably arising from subtle matrix effects.

  16. Diclofenac in municipal wastewater treatment plant: quantification using laser diode thermal desorption--atmospheric pressure chemical ionization--tandem mass spectrometry approach in comparison with an established liquid chromatography-electrospray ionization-tandem mass spectrometry method.

    PubMed

    Lonappan, Linson; Pulicharla, Rama; Rouissi, Tarek; Brar, Satinder K; Verma, Mausam; Surampalli, Rao Y; Valero, José R

    2016-02-12

    Diclofenac (DCF), a prevalent non-steroidal anti-inflammatory drug (NSAID) is often detected in wastewater and surface water. Analysis of the pharmaceuticals in complex matrices is often laden with challenges. In this study a reliable, rapid and sensitive method based on laser diode thermal desorption/atmospheric pressure chemical ionization (LDTD/APCI) coupled with tandem mass spectrometry (MS/MS) has been developed for the quantification of DCF in wastewater and wastewater sludge. An established conventional LC-ESI-MS/MS (liquid chromatography-electrospray ionization-tandem mass spectrometry) method was compared with LDTD-APCI-MS/MS approach. The newly developed LDTD-APCI-MS/MS method reduced the analysis time to 12s in lieu of 12 min for LC-ESI-MS/MS method. The method detection limits for LDTD-APCI-MS/MS method were found to be 270 ng L(-1) (LOD) and 1000 ng L(-1) (LOQ). Furthermore, two extraction procedures, ultrasonic assisted extraction (USE) and accelerated solvent extraction (ASE) for the extraction of DCF from wastewater sludge were compared and ASE with 95.6 ± 7% recovery was effective over USE with 86 ± 4% recovery. The fate and partitioning of DCF in wastewater (WW) and wastewater sludge (WWS) in wastewater treatment plant was also monitored at various stages of treatment in Quebec Urban community wastewater treatment plant. DCF exhibited affinity towards WW than WWS with a presence about 60% of DCF in WW in contrary with theoretical prediction (LogKow=4.51). Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Integrated LC-MS/MS Analytical Systems and Physical Inspection for the Analysis of a Botanical Herbal Preparation.

    PubMed

    Lai, Kuan-Ming; Cheng, Yung-Yi; Tsai, Tung-Hu

    2015-06-09

    The herbal decoction process is generally inconvenient and unpleasant. To avoid using herbal medicine decoctions, various high-quality industrial and pharmaceutical herbal decoction products have been used in clinical applications for more than ten years in Taiwan. However, the consistency and standardization of the quality of these herbal medicines are goals that remain to be achieved. The aim of study was to develop a validated liquid chromatography-tandem electrospray ionization mass spectrometry (LC-MS/MS) method to determine the biomarkers astragaloside I, astragaloside IV, formononetin, cinnamic acid, paeoniflorin and gingerol in the herbal preparation known as Huangqi-Guizhi-Wuwu (HGW). To investigate the physical quality of HGW, methods such as scanning electron microscopy, light microscopy with Congo red and potassium iodine staining, solubility measurements, swelling power tests, and crude fiber analysis were used to identify additives in commercial pharmaceutical products. The optimal LC-MS/MS multiple reaction-monitoring system included a gradient program using 5 mM ammonium acetate buffer with 0.05% formic acid/methanol. The results demonstrate deviations in biomarker content across different brands. In addition to the herbal extract, starch and excipients in the pharmaceutical granule, and crushed crude herb powder was added to the pharmaceutical products to increase their herbal ingredient content. In conclusion, a rigorous examination should be performed to certify the quality of the herbal products.

  18. Urine Multi-drug Screening with GC-MS or LC-MS-MS Using SALLE-hybrid PPT/SPE.

    PubMed

    Lee, Junhui; Park, Jiwon; Go, Ahra; Moon, Heesung; Kim, Sujin; Jung, Sohee; Jeong, Wonjoon; Chung, Heesun

    2018-05-14

    To intoxicated patients in the emergency room, toxicological analysis can be considerably helpful for identifying the involved toxicants. In order to develop a urine multi-drug screening (UmDS) method, gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS-MS) were used to determine targeted and unknown toxicants in urine. A GC-MS method in scan mode was validated for selectivity, limit of detection (LOD) and recovery. An LC-MS-MS multiple reaction monitoring (MRM) method was validated for lower LOD, recovery and matrix effect. The results of the screening analysis were compared with patient medical records to check the reliability of the screen. Urine samples collected from an emergency room were extracted through a combination of salting-out assisted liquid-liquid extraction (SALLE) and hybrid protein precipitation/solid phase extraction (hybrid PPT/SPE) plates and examined by GC-MS and LC-MS-MS. GC-MS analysis was performed as unknown drug screen and LC-MS-MS analysis was conducted as targeted drug screen. After analysis by GC-MS, a library search was conducted using an in-house library established with the automated mass spectral deconvolution and identification system (AMDISTM). LC-MS-MS used Cliquid®2.0 software for data processing and acquisition in MRM mode. An UmDS method by GC-MS and LC-MS-MS was developed by using a SALLE-hybrid PPT/SPE and in-house library. The results of UmDS by GC-MS and LC-MS-MS showed that toxicants could be identified from 185 emergency room patient samples containing unknown toxicants. Zolpidem, acetaminophen and citalopram were the most frequently encountered drugs in emergency room patients. The UmDS analysis developed in this study can be used effectively to detect toxic substances in a short time. Hence, it could be utilized in clinical and forensic toxicology practices.

  19. Attribution of the discrepancy between ELISA and LC-MS/MS assay results of a PEGylated scaffold protein in post-dose monkey plasma samples due to the presence of anti-drug antibodies.

    PubMed

    Wang, Shujie J; Wu, Steven T; Gokemeijer, Jochem; Fura, Aberra; Krishna, Murli; Morin, Paul; Chen, Guodong; Price, Karen; Wang-Iverson, David; Olah, Timothy; Weiner, Russell; Tymiak, Adrienne; Jemal, Mohammed

    2012-01-01

    High-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) and enzyme-linked immunosorbent assay (ELISA) methods were developed for the quantification of a PEGylated scaffold protein drug in monkey plasma samples. The LC-MS/MS method was based on the extraction of the therapeutic protein with a water-miscible organic solvent and the subsequent trypsin digestion of the extract followed by the detection of a surrogate peptide. The assay was linear over a range of 10-3,000 ng/mL. The ELISA method utilized a therapeutic target-binding format in which the recombinant target antigen was used to capture the drug in the sample, followed by detection with an anti-PEG monoclonal antibody. The assay range was 30-2,000 ng/mL. A correlation study between the two methods was performed by measuring the drug concentrations in plasma samples from a single-dose pharmacokinetic (PK) study in cynomolgus monkeys following a 5-mg/kg subcutaneous administration (n = 4). In the early time points of the PK profile, the drug concentrations obtained by the LC-MS/MS method agreed very well with those obtained by the ELISA method. However, at later time points, the drug concentrations measured by the LC-MS/MS method were consistently higher than those measured by the ELISA method. The PK parameters calculated based on the concentration data showed that the two methods gave equivalent peak exposure (C(max)) at 24-48 h. However, the LC-MS/MS results exhibited about 1.53-fold higher total exposure (AUC(tot)) than the ELISA results. The discrepancy between the LC-MS/MS and ELISA results was investigated by conducting immunogenicity testing, anti-drug antibody (ADA) epitope mapping, and Western blot analysis of the drug concentrations coupled with Protein G separation. The results demonstrated the presence of ADA specific to the engineered antigen-binding region of the scaffold protein drug that interfered with the ability of the drug to bind to the target antigen used in the ELISA method. In the presence of the ADAs, the ELISA method measured only the active circulating drug (target-binding), while the LC-MS/MS method measured the total circulating drug. The work presented here indicates that the bioanalysis of protein drugs may be complicated owing to the presence of drug-binding endogenous components or ADAs in the post-dose (incurred) samples. The clear understanding of the behavior of different bioanalytical techniques vis-à-vis the potentially interfering components found in incurred samples is critical in selecting bioanalytical strategies for measuring protein drugs.

  20. A Targeted LC-MS/MS Method for the Simultaneous Detection and Quantitation of Egg, Milk, and Peanut Allergens in Sugar Cookies.

    PubMed

    Boo, Chelsea C; Parker, Christine H; Jackson, Lauren S

    2018-01-01

    Food allergy is a growing public health concern, with many individuals reporting allergies to multiple food sources. Compliance with food labeling regulations and prevention of inadvertent cross-contact in manufacturing requires the use of reliable methods for the detection and quantitation of allergens in processed foods. In this work, a novel liquid chromatography-tandem mass spectrometry multiple-reaction monitoring method for multiallergen detection and quantitation of egg, milk, and peanut was developed and evaluated in an allergen-incurred baked sugar cookie matrix. A systematic evaluation of method parameters, including sample extraction, concentration, and digestion, were optimized for candidate allergen peptide markers. The optimized method enabled the reliable detection and quantitation of egg, milk, and peanut allergens in sugar cookies, with allergen concentrations as low as 5 ppm allergen-incurred ingredient.

  1. A multi-residue method for characterization of endocrine disruptors in gaseous and particulate phases of ambient air

    NASA Astrophysics Data System (ADS)

    Alliot, Fabrice; Moreau-Guigon, Elodie; Bourges, Catherine; Desportes, Annie; Teil, Marie-Jeanne; Blanchard, Martine; Chevreuil, Marc

    2014-08-01

    A number of semi-volatile compounds occur in indoor air most of them being considered as potent endocrine disruptors and thus, exerting a possible impact upon health. To assess their concentration levels in indoor air, we developed and validated a method for sampling and multi-residue analysis of 58 compounds including phthalates, polycyclic aromatic hydrocarbons (PAHs), polybromodiphenylethers (PBDEs), polychlorobiphenyls (PCBs), parabens, bisphenol A (BPA) and tetrabromobisphenol A (TBBPA) in gaseous and particulate phases of air. We validated each step of procedures from extraction until analysis. Matrice spiking were performed at extraction, fractionation and purification stages. The more volatile compounds were analyzed with a gas chromatography system coupled with a mass spectrometer (GC/MS) or with a tandem mass spectrometer (GC/MS/MS). The less volatile compounds were analyzed with a liquid chromatography system coupled with a tandem mass spectrometer (LC/MS/MS). Labeled internal standard method was used ensuring high quantification accuracy. The instrumental detection limits were under 1 pg for all compounds and therefore, a limit of quantification averaging 1 pg m-3 for the gaseous and the particulate phases and a volume of 150 m3, except for phthalates, phenol compounds and BDE-209. Satisfactory recoveries were found except for phenol compounds. That method was successfully applied to several indoor air samples (office, apartment and day nursery) and most of the targeted compounds were quantified, mainly occurring in the gaseous phase. The most abundant were phthalates (up to 918 ng m-3 in total air), followed by PCBs > parabens > BPA > PAHs > PBDEs.

  2. Measurement and Visualization of Mass Transport for the Flowing Atmospheric Pressure Afterglow (FAPA) Ambient Mass-Spectrometry Source

    PubMed Central

    Pfeuffer, Kevin P.; Ray, Steven J.; Hieftje, Gary M.

    2014-01-01

    Ambient desorption/ionization mass spectrometry (ADI-MS) has developed into an important analytical field over the last nine years. The ability to analyze samples under ambient conditions while retaining the sensitivity and specificity of mass spectrometry has led to numerous applications and a corresponding jump in the popularity of this field. Despite the great potential of ADI-MS, problems remain in the areas of ion identification and quantification. Difficulties with ion identification can be solved through modified instrumentation, including accurate-mass or MS/MS capabilities for analyte identification. More difficult problems include quantification due to the ambient nature of the sampling process. To characterize and improve sample volatilization, ionization, and introduction into the mass-spectrometer interface, a method of visualizing mass transport into the mass spectrometer is needed. Schlieren imaging is a well-established technique that renders small changes in refractive index visible. Here, schlieren imaging was used to visualize helium flow from a plasma-based ADI-MS source into a mass spectrometer while ion signals were recorded. Optimal sample positions for melting-point capillary and transmission-mode (stainless steel mesh) introduction were found to be near (within 1 mm of) the mass spectrometer inlet. Additionally, the orientation of the sampled surface plays a significant role. More efficient mass transport resulted for analyte deposits directly facing the MS inlet. Different surfaces (glass slide and rough surface) were also examined; for both it was found that the optimal position is immediately beneath the MS inlet. PMID:24658804

  3. Measurement and visualization of mass transport for the flowing atmospheric pressure afterglow (FAPA) ambient mass-spectrometry source.

    PubMed

    Pfeuffer, Kevin P; Ray, Steven J; Hieftje, Gary M

    2014-05-01

    Ambient desorption/ionization mass spectrometry (ADI-MS) has developed into an important analytical field over the last 9 years. The ability to analyze samples under ambient conditions while retaining the sensitivity and specificity of mass spectrometry has led to numerous applications and a corresponding jump in the popularity of this field. Despite the great potential of ADI-MS, problems remain in the areas of ion identification and quantification. Difficulties with ion identification can be solved through modified instrumentation, including accurate-mass or MS/MS capabilities for analyte identification. More difficult problems include quantification because of the ambient nature of the sampling process. To characterize and improve sample volatilization, ionization, and introduction into the mass spectrometer interface, a method of visualizing mass transport into the mass spectrometer is needed. Schlieren imaging is a well-established technique that renders small changes in refractive index visible. Here, schlieren imaging was used to visualize helium flow from a plasma-based ADI-MS source into a mass spectrometer while ion signals were recorded. Optimal sample positions for melting-point capillary and transmission-mode (stainless steel mesh) introduction were found to be near (within 1 mm of) the mass spectrometer inlet. Additionally, the orientation of the sampled surface plays a significant role. More efficient mass transport resulted for analyte deposits directly facing the MS inlet. Different surfaces (glass slide and rough surface) were also examined; for both it was found that the optimal position is immediately beneath the MS inlet.

  4. Measurement and Visualization of Mass Transport for the Flowing Atmospheric Pressure Afterglow (FAPA) Ambient Mass-Spectrometry Source

    NASA Astrophysics Data System (ADS)

    Pfeuffer, Kevin P.; Ray, Steven J.; Hieftje, Gary M.

    2014-05-01

    Ambient desorption/ionization mass spectrometry (ADI-MS) has developed into an important analytical field over the last 9 years. The ability to analyze samples under ambient conditions while retaining the sensitivity and specificity of mass spectrometry has led to numerous applications and a corresponding jump in the popularity of this field. Despite the great potential of ADI-MS, problems remain in the areas of ion identification and quantification. Difficulties with ion identification can be solved through modified instrumentation, including accurate-mass or MS/MS capabilities for analyte identification. More difficult problems include quantification because of the ambient nature of the sampling process. To characterize and improve sample volatilization, ionization, and introduction into the mass spectrometer interface, a method of visualizing mass transport into the mass spectrometer is needed. Schlieren imaging is a well-established technique that renders small changes in refractive index visible. Here, schlieren imaging was used to visualize helium flow from a plasma-based ADI-MS source into a mass spectrometer while ion signals were recorded. Optimal sample positions for melting-point capillary and transmission-mode (stainless steel mesh) introduction were found to be near (within 1 mm of) the mass spectrometer inlet. Additionally, the orientation of the sampled surface plays a significant role. More efficient mass transport resulted for analyte deposits directly facing the MS inlet. Different surfaces (glass slide and rough surface) were also examined; for both it was found that the optimal position is immediately beneath the MS inlet.

  5. The challenges of healthcare delivery to people with multiple sclerosis in Iran.

    PubMed

    Yazdannik, Ahmadreza; Abolhassani, Shahla; Taleghani, Fariba; Zamani, Ahmadreza

    2015-01-01

    Multiple sclerosis (MS) is a chronic disease prevalent in young and middle-aged people. Patients with MS often have numerous complicated needs and, consequently, require a broad range of health services. Results of a number of studies indicate that patients' needs are only partially met. This study was conducted to explore the challenges of healthcare delivery to patients with MS in Iran. In this qualitative case study, 43 participants selected through purposeful sampling were interviewed using semi-structured method in the cities of Isfahan and Tehran in 2012-2013. Besides the interview, documentations relevant to healthcare delivery were collected from different sources, including websites of all Iranian universities of medical sciences, insurance organizations, patients' weblogs, news agencies, the MS Center forum for MS patients, and MS Payam bimonthly. The data were analyzed through the constant comparative analysis. The data were categorized into four main categories, including functional challenges (diagnosis problems, failure to pay attention to patient needs, failure to follow-up, and miscommunication), administrative challenges (resource allocation and supervision), policy-making challenges (lack of comprehensive services, bureaucracy, and problems in provision of medications), and structural challenges (difficult access to services, lack of comprehensive centers, space limit, and long wait). Despite all attempts of governmental and nongovernmental organizations for healthcare delivery to MS patients, these services cannot satisfy all needs of the patients. In this regard, service providers and administrators should pay more attention to the needs and expectations of patients and their families.

  6. Direct identification of microorganisms from positive blood cultures by MALDI-TOF MS using an in-house saponin method.

    PubMed

    Yonetani, Shota; Ohnishi, Hiroaki; Ohkusu, Kiyofumi; Matsumoto, Tetsuya; Watanabe, Takashi

    2016-11-01

    Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) is a fast and reliable method for the identification of bacteria. A MALDI Sepsityper kit is generally used to prepare samples obtained directly from culture bottles. However, the relatively high cost of this kit is a major obstacle to introducing this method into routine clinical use. In this study, the accuracies of three different preparation methods for rapid direct identification of bacteria from positive blood culture bottles by MALDI-TOF MS analysis were compared. In total, 195 positive bottles were included in this study. Overall, 78.5%, 68.7%, and 76.4% of bacteria were correctly identified to the genus level (score ≥1.7) directly from positive blood cultures using the Sepsityper, centrifugation, and saponin methods, respectively. The identification rates using the Sepsityper and saponin methods were significantly higher than that using the centrifugation method (Sepsityper vs. centrifugation, p<0.001; saponin vs. centrifugation, p=0.003). These results suggest that the saponin method is superior to the centrifugation method and comparable to the Sepsityper method in the accuracy of rapid bacterial identification directly from blood culture bottles, and could be a less expensive alternative to the Sepsityper method. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  7. [Simultaneous determination of 4 diterpenoids in Rabdosia japonica var.glaucocalyx by HPLC-ESI-MS/MS and cluster analysis].

    PubMed

    Tian, Ting-Ting; Ma, Ying-Hua; Xie, Wei-Wei; Jin, Yi-Ran; Xu, Hui-Jun; Zhang, Lan-Tong; Du, Ying-Feng

    2016-01-01

    A quick HPLC-ESI-MS/MS method was established for simultaneous determination of four major diterpenoids in Rabdosia japonica var.glaucocalyx, including glaucocalyxin A, oridonin, hebeirubesensin and enmenol. Analysis was performed on an Agilent ZORBAX SB-C18(4.6 mm×250 mm, 5 μm ) column eluted in a gradient program with methanol and water. The flow rate was 0.8 mL•min⁻¹. Multiple reaction monitoring (MRM) scanning mode was performed in negative ion switching mode to apply for the quantitative determination. The calibration curves for the above four compounds were linear in corresponding injection amount. The average recoveries of the compounds ranged from 92.40% to 105.9%, with RSDs of 1.7%-6.5%. The method is simple, rapid, accurate with good repeatability, which can provide a reference for overcalling evaluation the quality of R. japonica var.glaucocalyx. The result of cluster analysis- showed that the quality of R. japonica glaucocalyx var. greatly varied between areas and parts. Copyright© by the Chinese Pharmaceutical Association.

  8. freeQuant: A Mass Spectrometry Label-Free Quantification Software Tool for Complex Proteome Analysis.

    PubMed

    Deng, Ning; Li, Zhenye; Pan, Chao; Duan, Huilong

    2015-01-01

    Study of complex proteome brings forward higher request for the quantification method using mass spectrometry technology. In this paper, we present a mass spectrometry label-free quantification tool for complex proteomes, called freeQuant, which integrated quantification with functional analysis effectively. freeQuant consists of two well-integrated modules: label-free quantification and functional analysis with biomedical knowledge. freeQuant supports label-free quantitative analysis which makes full use of tandem mass spectrometry (MS/MS) spectral count, protein sequence length, shared peptides, and ion intensity. It adopts spectral count for quantitative analysis and builds a new method for shared peptides to accurately evaluate abundance of isoforms. For proteins with low abundance, MS/MS total ion count coupled with spectral count is included to ensure accurate protein quantification. Furthermore, freeQuant supports the large-scale functional annotations for complex proteomes. Mitochondrial proteomes from the mouse heart, the mouse liver, and the human heart were used to evaluate the usability and performance of freeQuant. The evaluation showed that the quantitative algorithms implemented in freeQuant can improve accuracy of quantification with better dynamic range.

  9. High-throughput and targeted in-depth mass spectrometry-based approaches for biofluid profiling and biomarker discovery.

    PubMed

    Jimenez, Connie R; Piersma, Sander; Pham, Thang V

    2007-12-01

    Proteomics aims to create a link between genomic information, biological function and disease through global studies of protein expression, modification and protein-protein interactions. Recent advances in key proteomics tools, such as mass spectrometry (MS) and (bio)informatics, provide tremendous opportunities for biomarker-related clinical applications. In this review, we focus on two complementary MS-based approaches with high potential for the discovery of biomarker patterns and low-abundant candidate biomarkers in biofluids: high-throughput matrix-assisted laser desorption/ionization time-of-flight mass spectroscopy-based methods for peptidome profiling and label-free liquid chromatography-based methods coupled to MS for in-depth profiling of biofluids with a focus on subproteomes, including the low-molecular-weight proteome, carrier-bound proteome and N-linked glycoproteome. The two approaches differ in their aims, throughput and sensitivity. We discuss recent progress and challenges in the analysis of plasma/serum and proximal fluids using these strategies and highlight the potential of liquid chromatography-MS-based proteomics of cancer cell and tumor secretomes for the discovery of candidate blood-based biomarkers. Strategies for candidate validation are also described.

  10. Determination of adrenaline, noradrenaline and corticosterone in rodent blood by ion pair reversed phase UHPLC-MS/MS.

    PubMed

    Bergh, Marianne Skov-Skov; Bogen, Inger Lise; Andersen, Jannike Mørch; Øiestad, Åse Marit Leere; Berg, Thomas

    2018-01-01

    A novel ion pair reversed phase ultra high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method for simultaneous determination of the stress hormones adrenaline, noradrenaline and corticosterone in rodent blood was developed and fully validated. Separations were performed on an Acquity HSS T3 column (2.1mm i.d.×100mm, 1.8μm) with gradient elution and a runtime of 5.5min. The retention of adrenaline and noradrenaline was substantially increased by employing the ion pair reagent heptafluorobutyric acid (HFBA). Ion pair reagents are usually added to the mobile phase only, but we demonstrate for the first time that including HFBA to the sample reconstitution solvent as well, has a major impact on the chromatography of these compounds. The stability of adrenaline and corticosterone in rodent blood was investigated using the surrogate analytes adrenaline-d 3 and corticosterone-d 8 . The applicability of the described method was demonstrated by measuring the concentration of stress hormones in rodent blood samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Liquid chromatography with isotope-dilution mass spectrometry for determination of water-soluble vitamins in foods.

    PubMed

    Phillips, Melissa M

    2015-04-01

    Vitamins are essential for improving and maintaining human health, and the main source of vitamins is the diet. Measurement of the quantities of water-soluble vitamins in common food materials is important to understand the impact of vitamin intake on human health, and also to provide necessary information for regulators to determine adequate intakes. Liquid chromatography (LC) and mass spectrometry (MS) based methods for water-soluble vitamin analysis are abundant in the literature, but most focus on only fortified foods or dietary supplements or allow determination of only a single vitamin. In this work, a method based on LC/MS and LC/MS/MS has been developed to allow simultaneous quantitation of eight water-soluble vitamins, including multiple forms of vitamins B3 and B6, in a variety of fortified and unfortified food-matrix Standard Reference Materials (SRMs). Optimization of extraction of unbound vitamin forms and confirmation using data from external laboratories ensured accuracy in the assigned values, and addition of stable isotope labeled internal standards for each of the vitamins allowed for increased precision.

  12. Elucidation of Prion Protein Conformational Changes Associated with Infectivity by Fluorescence Spectroscopy

    DTIC Science & Technology

    2007-06-01

    developed the β-spiral model for PrPSc structure by using molecular dynamics simulations with the sequence of human PrPC (residues 90-231) under...SUPPLEMENTARY NOTES exerpts from thesis of Jessica Gilbert 14. ABSTRACT Steady state and lifetime fluorescence measurements were made on 12...lieu of F. We tried both methods. See Ms. Jessica Gilbert’s MS thesis for details, which is included. 6 Figure 4. Acrylamide quenching of Trp

  13. The potential of combining ion trap/MS/MS and TOF/MS for identification of emerging contaminants

    USGS Publications Warehouse

    Ferrer, I.; Furlong, E.T.; Heine, C.E.; Thurman, E.M.

    2002-01-01

    The use of a method combining ion trap tandem mass spectrometry (MS/MS) and time of flight mass spectrometry (TOF/MS) for identification of emerging contaminates was discussed. The two tools together complemented each other in sensitivity, fragmentation and accurate mass determination. Liquid chromatography/electrospray ionization/ion-trap tandem mass spectrometry (LC/ESI/MS/MS), in positive ion mode of operation, was used to separate and identify specific compounds. Diagnostic fragment ions were obtained for a polyethyleneglycol(PEG) homolog by ion trap MS/MS, and fragments were measured by TOF/MS. It was observed that the combined method gave an exact mass measurement that differed from the calculated mass.

  14. Fourier transform power spectrum is a potential measure of tissue alignment in standard MRI: A multiple sclerosis study.

    PubMed

    Sharma, Shrushrita; Zhang, Yunyan

    2017-01-01

    Loss of tissue coherency in brain white matter is found in many neurological diseases such as multiple sclerosis (MS). While several approaches have been proposed to evaluate white matter coherency including fractional anisotropy and fiber tracking in diffusion-weighted imaging, few are available for standard magnetic resonance imaging (MRI). Here we present an image post-processing method for this purpose based on Fourier transform (FT) power spectrum. T2-weighted images were collected from 19 patients (10 relapsing-remitting and 9 secondary progressive MS) and 19 age- and gender-matched controls. Image processing steps included: computation, normalization, and thresholding of FT power spectrum; determination of tissue alignment profile and dominant alignment direction; and calculation of alignment complexity using a new measure named angular entropy. To test the validity of this method, we used a highly organized brain white matter structure, corpus callosum. Six regions of interest were examined from the left, central and right aspects of both genu and splenium. We found that the dominant orientation of each ROI derived from our method was significantly correlated with the predicted directions based on anatomy. There was greater angular entropy in patients than controls, and a trend to be greater in secondary progressive MS patients. These findings suggest that it is possible to detect tissue alignment and anisotropy using traditional MRI, which are routinely acquired in clinical practice. Analysis of FT power spectrum may become a new approach for advancing the evaluation and management of patients with MS and similar disorders. Further confirmation is warranted.

  15. Recent developments in capabilities for analysing chlorinated paraffins in environmental matrices: A review.

    PubMed

    van Mourik, Louise M; Leonards, Pim E G; Gaus, Caroline; de Boer, Jacob

    2015-10-01

    Concerns about the high production volumes, persistency, bioaccumulation potential and toxicity of chlorinated paraffin (CP) mixtures, especially short-chain CPs (SCCPs), are rising. However, information on their levels and fate in the environment is still insufficient, impeding international classifications and regulations. This knowledge gap is mainly due to the difficulties that arise with CP analysis, in particular the chromatographic separation within CPs and between CPs and other compounds. No fully validated routine analytical method is available yet and only semi-quantitative analysis is possible, although the number of studies reporting new and improved methods have rapidly increased since 2010. Better cleanup procedures that remove interfering compounds, and new instrumental techniques, which distinguish between medium-chain CPs (MCCPs) and SCCPs, have been developed. While gas chromatography coupled to an electron capture negative ionisation mass spectrometry (GC/ECNI-MS) remains the most commonly applied technique, novel and promising use of high resolution time of flight MS (TOF-MS) has also been reported. We expect that recent developments in high resolution TOF-MS and Orbitrap technologies will further improve the detection of CPs, including long-chain CPs (LCCPs), and the group separation and quantification of CP homologues. Also, new CP quantification methods have emerged, including the use of mathematical algorithms, multiple linear regression and principal component analysis. These quantification advancements are also reflected in considerably improved interlaboratory agreements since 2010. Analysis of lower chlorinated paraffins (

  16. Simultaneous determination of 41 multiclass organic pollutants in environmental waters by means of polyethersulfone microextraction followed by liquid chromatography-tandem mass spectrometry.

    PubMed

    Mijangos, Leire; Ziarrusta, Haizea; Olivares, Maitane; Zuloaga, Olatz; Möder, Monika; Etxebarria, Nestor; Prieto, Ailette

    2018-01-01

    A new procedure using polyethersulfone (PES) microextraction followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis was developed in this work for the simultaneous determination of 41 multiclass priority and emerging organic pollutants including herbicides, hormones, personal care products, and pharmaceuticals, among others, in seawater, wastewater treatment plant (WWTP) effluents, and estuary samples. The optimization of the analysis included two different chromatographic columns and different variables (polarity, fragmentor voltage, collision energy, and collision cell accelerator) of the mass spectrometer. In the case of PES extraction, ion strength of the water, pH, addition of EDTA, and the amount of the polymeric material were thoroughly investigated. The developed procedure was compared with a previously validated one based on a standard solid-phase extraction (SPE). In contrast to the SPE protocol, the PES method allowed a cost-efficient extraction of complex aqueous samples with lower matrix effect from 120 mL of water sample. Satisfactory and comparable apparent recovery values (80-119 and 70-131%) and method quantification limits (MQLs, 0.4-26 and 0.2-23 ng/L) were obtained for PES and SPE procedures, respectively, regardless of the matrix. Repeatability values lower than 27% were obtained. Finally, the developed methods were applied to the analysis of real samples from the Basque Country and irbesartan, valsartan, acesulfame, and sucralose were the analytes most often detected at the highest concentrations (51-1096 ng/L). Graphical abstract Forty-one multiclass pollutant determination in environmental waters by means of PES/SPE-LC-MS/MS.

  17. Analysis of Urinary Metabolites of Nerve and Blister Chemical Warfare Agents

    DTIC Science & Technology

    2014-08-01

    of CWAs. The analysis methods use UHPLC-MS/MS in Multiple Reaction Monitoring ( MRM ) mode to enhance the selectivity and sensitivity of the method...Chromatography Mass Spectrometry LOD Limit Of Detection LOQ Limit of Quantitation MRM Multiple Reaction Monitoring MSMS Tandem mass...urine [1]. Those analysis methods use UHPLC- MS/MS in Multiple Reaction Monitoring ( MRM ) mode to enhance the selectivity and sensitivity of the method

  18. Ambient Mass Spectrometry in Cancer Research.

    PubMed

    Takats, Z; Strittmatter, N; McKenzie, J S

    2017-01-01

    Ambient ionization mass spectrometry was developed as a sample preparation-free alternative to traditional MS-based workflows. Desorption electrospray ionization (DESI)-MS methods were demonstrated to allow the direct analysis of a broad range of samples including unaltered biological tissue specimens. In contrast to this advantageous feature, nowadays DESI-MS is almost exclusively used for sample preparation intensive mass spectrometric imaging (MSI) in the area of cancer research. As an alternative to MALDI, DESI-MSI offers matrix deposition-free experiment with improved signal in the lower (<500m/z) range. DESI-MSI enables the spatial mapping of tumor metabolism and has been broadly demonstrated to offer an alternative to frozen section histology for intraoperative tissue identification and surgical margin assessment. Rapid evaporative ionization mass spectrometry (REIMS) was developed exclusively for the latter purpose by the direct combination of electrosurgical devices and mass spectrometry. In case of the REIMS technology, aerosol particles produced by electrosurgical dissection are subjected to MS analysis, providing spectral information on the structural lipid composition of tissues. REIMS technology was demonstrated to give real-time information on the histological nature of tissues being dissected, deeming it an ideal tool for intraoperative tissue identification including surgical margin control. More recently, the method has also been used for the rapid lipidomic phenotyping of cancer cell lines as it was demonstrated in case of the NCI-60 cell line collection. © 2017 Elsevier Inc. All rights reserved.

  19. Simultaneous measurement of NAD metabolome in aged mice tissue using liquid chromatography tandem-mass spectrometry.

    PubMed

    Yaku, Keisuke; Okabe, Keisuke; Nakagawa, Takashi

    2018-06-01

    Nicotinamide adenine dinucleotide (NAD) is a major co-factor that mediates multiple biological processes including redox reaction and gene expression. Recently, NAD metabolism has received considerable attention because administration of NAD precursors exhibited beneficial effects against aging-related metabolic disorders in animals. Although numerous studies have reported that NAD levels decline with aging in multiple animal tissues, the pathway and kinetics of NAD metabolism in aged organs are not completely understood. To determine the NAD metabolism upon aging, we developed targeted metabolomics based on an LC/MS/MS system. Our method is simple and applicable to crude biological samples, including culture cells and animal tissues. Unlike a conventional enzymatic cycling assay, our approach can determine NAD and NADH (reduced form of NAD) by performing a single sample preparation. Further, we validated our method using biological samples and investigated the alteration of the NAD metabolome during aging. Consistent with previous reports, the NAD levels in the liver and skeletal muscle decreased with aging. Further, we detected a significant increase in nicotinamide mononucleotide and nicotinamide riboside in the kidney upon aging. The LC/MS/MS-based NAD metabolomics that we have developed is extensively applicable to biomedical studies, and the results will present innovative ideas for the aging studies, especially for that of NAD metabolism. Copyright © 2018 John Wiley & Sons, Ltd.

  20. Protein mass analysis of histones.

    PubMed

    Galasinski, Scott C; Resing, Katheryn A; Ahn, Natalie G

    2003-09-01

    Posttranslational modification of chromatin-associated proteins, including histones and high-mobility-group (HMG) proteins, provides an important mechanism to control gene expression, genome integrity, and epigenetic inheritance. Protein mass analysis provides a rapid and unbiased approach to monitor multiple chemical modifications on individual molecules. This review describes methods for acid extraction of histones and HMG proteins, followed by separation by reverse-phase chromatography coupled to electrospray ionization mass spectrometry (LC/ESI-MS). Posttranslational modifications are detected by analysis of full-length protein masses. Confirmation of protein identity and modification state is obtained through enzymatic digestion and peptide sequencing by MS/MS. For differentially modified forms of each protein, the measured intensities are semiquantitative and allow determination of relative abundance and stoichiometry. The method simultaneously detects covalent modifications on multiple proteins and provides a facile assay for comparing chromatin modification states between different cell types and/or cellular responses.

  1. A simultaneous quantitative method for vitamins A, D and E in human serum using liquid chromatography-tandem mass spectrometry.

    PubMed

    Albahrani, Ali A; Rotarou, Victor; Roche, Peter J; Greaves, Ronda F

    2016-05-01

    Non-classical roles of fat-soluble vitamins (FSVs) in many pathologies including cancer have been identified. There is also evidence of hormonal interactions between two of these vitamins, A and D. As a result of this enhanced clinical association with disease, translational clinical research and laboratory requests for FSV measurement has significantly increased. However there are still gaps in the analytical methods available for the measurement of these vitamins. This study aimed to develop a method for simultaneous quantification of 25-hydroxyvitamin-D2 (25-OHD2), 25-hydroxyvitamin-D3 (25-OHD3) and its 3-epimer (epi-25-OHD3), retinol and α-tocopherol in human serum using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The procedure was developed and validated across two LC-MS/MS platforms, using commercial calibrators referenced to certified reference materials, controls, and deuterated internal standards. The samples were prepared by liquid-liquid extraction prior to injection and LC separation (using a Pursuit-PFP column) on two Agilent MS/MS systems (6410 and 6490) in electrospray ionisation positive mode with multiple reaction monitoring. Identification and quantification of 25-OHD3 from its 3-epimer as well as 25-OHD2, retinol and α-tocopherol were achieved. The dynamic ranges were 4-160 nmol/L for 25-OHD2 and epi-25-OHD3, 4-200 nmol/L for 25-OHD3, 0.1-4.0μmol/L for retinol and 4-70μmol/L for α-tocopherol with correlation (r(2)) of 0.997-0.998. Based on participation in an external quality assurance program, the overall performance of the simultaneous methods were: imprecision (CV%) and inaccuracy (average bias) 3.0% and 3.2 nmol/L, respectively, for 25-OHD3; 5.0% and 0.04μmol/L, respectively, for retinol; and 4.7% and 0.2μmol/L, respectively, for α-tocopherol. In summary, two simple LC-MS/MS methods were successfully developed and validated for the simultaneous quantification of the three vitamin D metabolites (25-OHD2, 25-OHD3 and 3-epimer of 25-OHD3), vitamin A (retinol) and vitamin E (α-tocopherol) in serum. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. How mass spectrometric approaches applied to bacterial identification have revolutionized the study of human gut microbiota.

    PubMed

    Grégory, Dubourg; Chaudet, Hervé; Lagier, Jean-Christophe; Raoult, Didier

    2018-03-01

    Describing the human hut gut microbiota is one the most exciting challenges of the 21 st century. Currently, high-throughput sequencing methods are considered as the gold standard for this purpose, however, they suffer from several drawbacks, including their inability to detect minority populations. The advent of mass-spectrometric (MS) approaches to identify cultured bacteria in clinical microbiology enabled the creation of the culturomics approach, which aims to establish a comprehensive repertoire of cultured prokaryotes from human specimens using extensive culture conditions. Areas covered: This review first underlines how mass spectrometric approaches have revolutionized clinical microbiology. It then highlights the contribution of MS-based methods to culturomics studies, paying particular attention to the extension of the human gut microbiota repertoire through the discovery of new bacterial species. Expert commentary: MS-based approaches have enabled cultivation methods to be resuscitated to study the human gut microbiota and thus to fill in the blanks left by high-throughput sequencing methods in terms of culturing minority populations. Continued efforts to recover new taxa using culture methods, combined with their rapid implementation in genomic databases, would allow for an exhaustive analysis of the gut microbiota through the use of a comprehensive approach.

  3. Certification of NIST standard reference material 2389a, amino acids in 0.1 mol/L HCl--quantification by ID LC-MS/MS.

    PubMed

    Lowenthal, Mark S; Yen, James; Bunk, David M; Phinney, Karen W

    2010-05-01

    An isotope-dilution liquid chromatography-tandem mass spectrometry (ID LC-MS/MS) measurement procedure was developed to accurately quantify amino acid concentrations in National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 2389a-amino acids in 0.1 mol/L hydrochloric acid. Seventeen amino acids were quantified using selected reaction monitoring on a triple quadrupole mass spectrometer. LC-MS/MS results were compared to gravimetric measurements from the preparation of SRM 2389a-a reference material developed at NIST and intended for use in intra-laboratory calibrations and quality control. Quantitative mass spectrometry results and gravimetric values were statistically combined into NIST-certified mass fraction values with associated uncertainty estimates. Coefficients of variation (CV) for the repeatability of the LC-MS/MS measurements among amino acids ranged from 0.33% to 2.7% with an average CV of 1.2%. Average relative expanded uncertainty of the certified values including Types A and B uncertainties was 3.5%. Mean accuracy of the LC-MS/MS measurements with gravimetric preparation values agreed to within |1.1|% for all amino acids. NIST SRM 2389a will be available for characterization of routine methods for amino acid analysis and serves as a standard for higher-order measurement traceability. This is the first time an ID LC-MS/MS methodology has been applied for quantifying amino acids in a NIST SRM material.

  4. Development of analytical methods for multiplex bio-assay with inductively coupled plasma mass spectrometry

    PubMed Central

    Ornatsky, Olga I.; Kinach, Robert; Bandura, Dmitry R.; Lou, Xudong; Tanner, Scott D.; Baranov, Vladimir I.; Nitz, Mark; Winnik, Mitchell A.

    2008-01-01

    Advances in the development of highly multiplexed bio-analytical assays with inductively coupled plasma mass spectrometry (ICP-MS) detection are discussed. Use of novel reagents specifically designed for immunological methods utilizing elemental analysis is presented. The major steps of method development, including selection of elements for tags, validation of tagged reagents, and examples of multiplexed assays, are considered in detail. The paper further describes experimental protocols for elemental tagging of antibodies, immunostaining of live and fixed human leukemia cells, and preparation of samples for ICP-MS analysis. Quantitative analysis of surface antigens on model cell lines using a cocktail of seven lanthanide labeled antibodies demonstrated high specificity and concordance with conventional immunophenotyping. PMID:19122859

  5. ms2: A molecular simulation tool for thermodynamic properties

    NASA Astrophysics Data System (ADS)

    Deublein, Stephan; Eckl, Bernhard; Stoll, Jürgen; Lishchuk, Sergey V.; Guevara-Carrion, Gabriela; Glass, Colin W.; Merker, Thorsten; Bernreuther, Martin; Hasse, Hans; Vrabec, Jadran

    2011-11-01

    This work presents the molecular simulation program ms2 that is designed for the calculation of thermodynamic properties of bulk fluids in equilibrium consisting of small electro-neutral molecules. ms2 features the two main molecular simulation techniques, molecular dynamics (MD) and Monte-Carlo. It supports the calculation of vapor-liquid equilibria of pure fluids and multi-component mixtures described by rigid molecular models on the basis of the grand equilibrium method. Furthermore, it is capable of sampling various classical ensembles and yields numerous thermodynamic properties. To evaluate the chemical potential, Widom's test molecule method and gradual insertion are implemented. Transport properties are determined by equilibrium MD simulations following the Green-Kubo formalism. ms2 is designed to meet the requirements of academia and industry, particularly achieving short response times and straightforward handling. It is written in Fortran90 and optimized for a fast execution on a broad range of computer architectures, spanning from single processor PCs over PC-clusters and vector computers to high-end parallel machines. The standard Message Passing Interface (MPI) is used for parallelization and ms2 is therefore easily portable to different computing platforms. Feature tools facilitate the interaction with the code and the interpretation of input and output files. The accuracy and reliability of ms2 has been shown for a large variety of fluids in preceding work. Program summaryProgram title:ms2 Catalogue identifier: AEJF_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEJF_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Special Licence supplied by the authors No. of lines in distributed program, including test data, etc.: 82 794 No. of bytes in distributed program, including test data, etc.: 793 705 Distribution format: tar.gz Programming language: Fortran90 Computer: The simulation tool ms2 is usable on a wide variety of platforms, from single processor machines over PC-clusters and vector computers to vector-parallel architectures. (Tested with Fortran compilers: gfortran, Intel, PathScale, Portland Group and Sun Studio.) Operating system: Unix/Linux, Windows Has the code been vectorized or parallelized?: Yes. Message Passing Interface (MPI) protocol Scalability. Excellent scalability up to 16 processors for molecular dynamics and >512 processors for Monte-Carlo simulations. RAM:ms2 runs on single processors with 512 MB RAM. The memory demand rises with increasing number of processors used per node and increasing number of molecules. Classification: 7.7, 7.9, 12 External routines: Message Passing Interface (MPI) Nature of problem: Calculation of application oriented thermodynamic properties for rigid electro-neutral molecules: vapor-liquid equilibria, thermal and caloric data as well as transport properties of pure fluids and multi-component mixtures. Solution method: Molecular dynamics, Monte-Carlo, various classical ensembles, grand equilibrium method, Green-Kubo formalism. Restrictions: No. The system size is user-defined. Typical problems addressed by ms2 can be solved by simulating systems containing typically 2000 molecules or less. Unusual features: Feature tools are available for creating input files, analyzing simulation results and visualizing molecular trajectories. Additional comments: Sample makefiles for multiple operation platforms are provided. Documentation is provided with the installation package and is available at http://www.ms-2.de. Running time: The running time of ms2 depends on the problem set, the system size and the number of processes used in the simulation. Running four processes on a "Nehalem" processor, simulations calculating VLE data take between two and twelve hours, calculating transport properties between six and 24 hours.

  6. Development and Bioanalytical Validation of a Liquid Chromatographic-Tandem Mass Spectrometric (LC-MS/MS) Method for the Quantification of the CCR5 Antagonist Maraviroc in Human Plasma

    PubMed Central

    Emory, Joshua F.; Seserko, Lauren A.; Marzinke, Mark A.

    2014-01-01

    Background Maraviroc is a CCR5 antagonist that has been utilized as a viral entry inhibitor in the management of HIV-1. Current clinical trials are pursuing maraviroc drug efficacy in both oral and topical formulations. Therefore, in order to fully understand drug pharmacokinetics, a sensitive method is required to quantify plasma drug concentrations. Methods Maraviroc-spiked plasma was combined with acetonitrile containing an isotopically-labeled internal standard, and following protein precipitation, samples were evaporated to dryness and reconstituted for liquid chromatographic-tandem mass spectrometric (LC-MS/MS) analysis. Chromatographic separation was achieved on a Waters BEH C8, 50 × 2.1 mm UPLC column, with a 1.7 μm particle size and the eluent was analyzed using an API 4000 mass analyzer in selected reaction monitoring mode. The method was validated as per FDA Bioanalytical Method Validation guidelines. Results The analytical measuring range of the LC-MS/MS method is 0.5-1000 ng/ml. Calibration curves were generated using weighted 1/x2 quadratic regression. Inter-and intra-assay precision was ≤ 5.38% and ≤ 5.98%, respectively; inter-and intra-assay accuracy (%DEV) was ≤ 10.2% and ≤ 8.44%, respectively. Additional studies illustrated similar matrix effects between maraviroc and its internal standard, and that maraviroc is stable under a variety of conditions. Method comparison studies with a reference LC-MS/MS method show a slope of 0.948 with a Spearman coefficient of 0.98. Conclusions Based on the validation metrics, we have generated a sensitive and automated LC-MS/MS method for maraviroc quantification in human plasma. PMID:24561264

  7. LC-MS/MS Peptide Mapping with Automated Data Processing for Routine Profiling of N-Glycans in Immunoglobulins

    NASA Astrophysics Data System (ADS)

    Shah, Bhavana; Jiang, Xinzhao Grace; Chen, Louise; Zhang, Zhongqi

    2014-06-01

    Protein N-Glycan analysis is traditionally performed by high pH anion exchange chromatography (HPAEC), reversed phase liquid chromatography (RPLC), or hydrophilic interaction liquid chromatography (HILIC) on fluorescence-labeled glycans enzymatically released from the glycoprotein. These methods require time-consuming sample preparations and do not provide site-specific glycosylation information. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) peptide mapping is frequently used for protein structural characterization and, as a bonus, can potentially provide glycan profile on each individual glycosylation site. In this work, a recently developed glycopeptide fragmentation model was used for automated identification, based on their MS/MS, of N-glycopeptides from proteolytic digestion of monoclonal antibodies (mAbs). Experimental conditions were optimized to achieve accurate profiling of glycoforms. Glycan profiles obtained from LC-MS/MS peptide mapping were compared with those obtained from HPAEC, RPLC, and HILIC analyses of released glycans for several mAb molecules. Accuracy, reproducibility, and linearity of the LC-MS/MS peptide mapping method for glycan profiling were evaluated. The LC-MS/MS peptide mapping method with fully automated data analysis requires less sample preparation, provides site-specific information, and may serve as an alternative method for routine profiling of N-glycans on immunoglobulins as well as other glycoproteins with simple N-glycans.

  8. Characterizing fluorotelomer and polyfluoroalkyl substances in new and aged fluorotelomer-based polymers for degradation studies with GC/MS and LC/MS/MS.

    PubMed

    Washington, John W; Naile, Jonathan E; Jenkins, Thomas M; Lynch, David G

    2014-05-20

    Fluorotelomer-based polymers (FTPs), the dominant product of the fluorotelomer industry, are antistaining and antiwetting agents that permeate the products and surfaces of modern society. However, the degree to which these materials expose humans and the environment to fluorotelomer and perfluorinated compounds, including recalcitrant and toxic compounds such as perfluorooctanoic acid (PFOA), is ill-defined. The design intent of FTPs, to minimize interaction with other substances, including solvents, heretofore has stymied efforts to develop robust methods to characterize the content of monomers and associated compounds of new commercial FTPs, as well as commercial FTPs that have been aged in environmental media for degradation testing. Here we show that FTPs can be exhausted of these compounds and quantitated by (i) drying the FTP on a suitable substrate at elevated temperature to achieve low, constant monomer concentrations; (ii) serial extraction with MTBE for fluorotelomer-monomer analysis by GC/MS in PCI mode; followed by (iii) serial extraction with 90/10 ACN/H2O for polyfluorocompound analysis by LC/MS/MS in negative ESI mode. This approach yields exhaustive, internally consistent accounting of monomers and associated compounds for FTPs, either alone or in a soil matrix (representing an environmental medium), for both new and simulated-aged FTPs to allow degradation testing, and for fluorinated compounds at least as long as C12.

  9. Kidney function tests

    MedlinePlus

    Kidney function tests are common lab tests used to evaluate how well the kidneys are working. Such tests include: ... Oh MS, Briefel G. Evaluation of renal function, water, electrolytes ... and Management by Laboratory Methods . 23rd ed. Philadelphia, ...

  10. Analysis of Bisphenol A, Alkylphenols, and Alkylphenol Ethoxylates in NIST SRM 2585 and Indoor House Dust by Gas Chromatography-Tandem Mass Spectrometry (GC/MS/MS).

    PubMed

    Fan, Xinghua; Kubwabo, Cariton; Wu, Fang; Rasmussen, Pat E

    2018-06-26

    Background: Ingestion of house dust has been demonstrated to be an important exposure pathway to several contaminants in young children. These compounds include bisphenol A (BPA), alkylphenols (APs), and alkylphenol ethoxylates (APEOs). Analysis of these compounds in house dust is challenging because of the complex composition of the sample matrix. Objective: The objective was to develop a simple and sensitive method to measure BPA, APs, and APEOs in indoor house dust. Methods: An integrated method that involved solvent extraction using sonication, sample cleanup by solid-phase extraction, derivatization by 2,2,2-trifluoro- N -methyl- N -(trimethylsilyl)acetamide, and analysis by GC coupled with tandem MS was developed for the simultaneous determination of BPA, APs, and APEOs in NIST Standard Reference Material (SRM) 2585 (Organic contaminants in house dust) and in settled house dust samples. Results: Target analytes included BPA, 4- tert -octylphenol (OP), OP monoethoxylate, OP diethoxylate, 4- n -nonylphenol (4 n NP), 4 n NP monoethoxylate (4 n NP 1 EO), branched nonylphenol (NP), NP monoethoxylate, NP diethoxylate, NP triethoxylate, and NP tetraethoxylate. The method was sensitive, with method detection limits ranging from 0.05 to 5.1 μg/g, and average recoveries between 82 and 115%. All target analytes were detected in SRM 2585 and house dust except 4 n NP and 4 n NP 1 EO. Conclusions: The method is simple and fast, with high sensitivity and good reproducibility. It is applicable to the analysis of target analytes in similar matrixes, such as sediments, soil, and biosolids. Highlights: Values measured in SRM 2585 will be useful for future research in method development and method comparison.

  11. A sampling framework for incorporating quantitative mass spectrometry data in protein interaction analysis.

    PubMed

    Tucker, George; Loh, Po-Ru; Berger, Bonnie

    2013-10-04

    Comprehensive protein-protein interaction (PPI) maps are a powerful resource for uncovering the molecular basis of genetic interactions and providing mechanistic insights. Over the past decade, high-throughput experimental techniques have been developed to generate PPI maps at proteome scale, first using yeast two-hybrid approaches and more recently via affinity purification combined with mass spectrometry (AP-MS). Unfortunately, data from both protocols are prone to both high false positive and false negative rates. To address these issues, many methods have been developed to post-process raw PPI data. However, with few exceptions, these methods only analyze binary experimental data (in which each potential interaction tested is deemed either observed or unobserved), neglecting quantitative information available from AP-MS such as spectral counts. We propose a novel method for incorporating quantitative information from AP-MS data into existing PPI inference methods that analyze binary interaction data. Our approach introduces a probabilistic framework that models the statistical noise inherent in observations of co-purifications. Using a sampling-based approach, we model the uncertainty of interactions with low spectral counts by generating an ensemble of possible alternative experimental outcomes. We then apply the existing method of choice to each alternative outcome and aggregate results over the ensemble. We validate our approach on three recent AP-MS data sets and demonstrate performance comparable to or better than state-of-the-art methods. Additionally, we provide an in-depth discussion comparing the theoretical bases of existing approaches and identify common aspects that may be key to their performance. Our sampling framework extends the existing body of work on PPI analysis using binary interaction data to apply to the richer quantitative data now commonly available through AP-MS assays. This framework is quite general, and many enhancements are likely possible. Fruitful future directions may include investigating more sophisticated schemes for converting spectral counts to probabilities and applying the framework to direct protein complex prediction methods.

  12. Simultaneous quantification of cholesterol sulfate, androgen sulfates, and progestagen sulfates in human serum by LC-MS/MS.

    PubMed

    Sánchez-Guijo, Alberto; Oji, Vinzenz; Hartmann, Michaela F; Traupe, Heiko; Wudy, Stefan A

    2015-09-01

    Steroids are primarily present in human fluids in their sulfated forms. Profiling of these compounds is important from both diagnostic and physiological points of view. Here, we present a novel method for the quantification of 11 intact steroid sulfates in human serum by LC-MS/MS. The compounds analyzed in our method, some of which are quantified for the first time in blood, include cholesterol sulfate, pregnenolone sulfate, 17-hydroxy-pregnenolone sulfate, 16-α-hydroxy-dehydroepiandrosterone sulfate, dehydroepiandrosterone sulfate, androstenediol sulfate, androsterone sulfate, epiandrosterone sulfate, testosterone sulfate, epitestosterone sulfate, and dihydrotestosterone sulfate. The assay was conceived to quantify sulfated steroids in a broad range of concentrations, requiring only 300 μl of serum. The method has been validated and its performance was studied at three quality controls, selected for each compound according to its physiological concentration. The assay showed good linearity (R(2) > 0.99) and recovery for all the compounds, with limits of quantification ranging between 1 and 80 ng/ml. Averaged intra-day and between-day precisions (coefficient of variation) and accuracies (relative errors) were below 10%. The method has been successfully applied to study the sulfated steroidome in diseases such as steroid sulfatase deficiency, proving its diagnostic value. This is, to our best knowledge, the most comprehensive method available for the quantification of sulfated steroids in human blood. Copyright © 2015 by the American Society for Biochemistry and Molecular Biology, Inc.

  13. Rapid and reliable determination of illegal adulterant in herbal medicines and dietary supplements by LC/MS/MS.

    PubMed

    Liang, Qionglin; Qu, Jun; Luo, Guoan; Wang, Yiming

    2006-02-13

    In recent years, dietary supplements and herbal medicines are increasing in popularity all over the world. However, it is problematic that some manufacturers illegally included synthetic drugs in their products. Due to the extremely complex matrices of those products, most existing methods for screening illegal adulterations are time-consuming and liable to false positive. In this paper, a robust LC/MS/MS method for the high-throughput, sensitive and reliable determination of illegal adulterations from herbal medicines and dietary supplements was established. Minimal LC separation was employed and MRM was used to simultaneously monitor the three transitions under their respective optimal collision energy for each compound. Positive results were determined only if well-defined peaks appeared at all of the three transitions and the ratios among the peak areas were within given threshold. In this study, the method had been applied for the screening of nine most commonly adulterated therapeutic substances, such as sildenafil (Viagra) and famotidine, and the lower limits of detection of these compounds ranged from 0.05 to 1.5 ng/ml. Little sample preparation was needed for this method and the analysis time was less than 5 min/sample. The reliability has been demonstrated by the test with blank matrix. Over 200 products that were under suspicion by SDA of China had been assayed and till now no false negative or positive result was found. This method is rapid, simple, reliable and capable of screening multiple adulterants in one run.

  14. Detecting a wide range of environmental contaminants in human blood samples--combining QuEChERS with LC-MS and GC-MS methods.

    PubMed

    Plassmann, Merle M; Schmidt, Magdalena; Brack, Werner; Krauss, Martin

    2015-09-01

    Exposure to environmental pollution and consumer products may result in an uptake of chemicals into human tissues. Several studies have reported the presence of diverse environmental contaminants in human blood samples. However, previously developed multi-target methods for the analysis of human blood include a fairly limited amount of compounds stemming from one or two related compound groups. Thus, the sample preparation method QuEChERS (quick easy cheap effective rugged and safe) was tested for the extraction of 64 analytes covering a broad compound domain followed by detection using liquid and gas chromatography coupled to mass spectrometry (LC- and GC-MS). Forty-seven analytes showed absolute recoveries above 70% in the first QuEChERS step, being a simple liquid-liquid extraction (LLE) using acetonitrile and salt. The second QuEChERS step, being a dispersive solid phase extraction, did not result in an overall improvement of recoveries or removal of background signals. Using solely the LLE step, eight analytes could subsequently be detected in human blood samples from the German Environmental Specimen Bank. Using a LC-multiple reaction monitoring (MRM) method with a triple quadrupole instrument, better recoveries were achieved than with an older LC-high-resolution (HR) MS full scan orbitrap instrument, which required a higher concentration factor of the extracts. However, the application of HRMS full scan methods could be used for the detection of additional compounds retrospectively.

  15. Simple and Robust N-Glycan Analysis Based on Improved 2-Aminobenzoic Acid Labeling for Recombinant Therapeutic Glycoproteins.

    PubMed

    Jeong, Yeong Ran; Kim, Sun Young; Park, Young Sam; Lee, Gyun Min

    2018-03-21

    N-glycans of therapeutic glycoproteins are critical quality attributes that should be monitored throughout all stages of biopharmaceutical development. To reduce both the time for sample preparation and the variations in analytical results, we have developed an N-glycan analysis method that includes improved 2-aminobenzoic acid (2-AA) labeling to easily remove deglycosylated proteins. Using this analytical method, 15 major 2-AA-labeled N-glycans of Enbrel ® were separated into single peaks in hydrophilic interaction chromatography mode and therefore could be quantitated. 2-AA-labeled N-glycans were also highly compatible with in-line quadrupole time-of-flight mass spectrometry (MS) for structural identification. The structures of 15 major and 18 minor N-glycans were identified from their mass values determined by quadrupole time-of-flight MS. Furthermore, the structures of 14 major N-glycans were confirmed by interpreting the MS/MS data of each N-glycan. This analytical method was also successfully applied to neutral N-glycans of Humira ® and highly sialylated N-glycans of NESP ® . Furthermore, the analysis data of Enbrel ® that were accumulated for 2.5 years demonstrated the high-level consistency of this analytical method. Taken together, the results show that a wide repertoire of N-glycans of therapeutic glycoproteins can be analyzed with high efficiency and consistency using the improved 2-AA labeling-based N-glycan analysis method. Copyright © 2018 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  16. Development and Validation of a Novel LC-MS/MS Opioid Confirmation Assay: Evaluation of β-glucuronidase Enzymes and Sample Cleanup Methods.

    PubMed

    Yang, He S; Wu, Alan H B; Lynch, Kara L

    2016-06-01

    With the rise in the use and misuse of prescription opioids, there is an increasing need for the confirmed identification of opioid analgesics in toxicology laboratories. The goals of this study were to (i) systematically evaluate the hydrolysis efficiency of four β-glucuronidase enzymes under optimized condition; (ii) evaluate compound recovery, matrix effects and precision of three protein precipitation plates and (iii) develop and validate a qualitative liquid-chromatography mass spectrometry (LC-MS/MS) assay to identify 13 opioids in urine. A recombinant β-glucuronidase exhibited the best overall hydrolysis efficiency for seven opioid glucuronide conjugates compared with β-glucuronidase from red abalone, Escherichia coli and Patella vulgata One of the protein precipitation plates tested exhibited overall better recovery of the opioids and lower ion suppression compared with the other two plates. An ESI positive mode LC-MS/MS assay for qualitative opioid analysis was developed and validated. Linearity, LOD, precision, matrix effect, recovery, carryover and interference of the method were evaluated. Sixty-two patient samples were analyzed by both a legacy GC-MS opioid method and the LC-MS/MS method, and 22 samples were analyzed by the LC-MS/MS and an LC-MS/MS reference method. The results of the comparisons showed good concordance. Overall, we described an efficient sample preparation procedure for a sensitive qualitative opioid confirmation assay in urine. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Profiling the Oxylipin and Endocannabinoid Metabolome by UPLC-ESI-MS/MS in Human Plasma to Monitor Postprandial Inflammation.

    PubMed

    Gouveia-Figueira, Sandra; Späth, Jana; Zivkovic, Angela M; Nording, Malin L

    2015-01-01

    Bioactive lipids, including oxylipins, endocannabinoids, and related compounds may function as specific biochemical markers of certain aspects of inflammation. However, the postprandial responsiveness of these compounds is largely unknown; therefore, changes in the circulating oxylipin and endocannabinoid metabolome in response to a challenge meal were investigated at six occasions in a subject who freely modified her usual diet. The dietary change, and especially the challenge meal itself, represented a modification of precursor fatty acid status, with expectedly subtle effects on bioactive lipid levels. To detect even the slightest alteration, highly sensitive ultra-performance liquid chromatography (UPLC) coupled to electrospray ionization (ESI) tandem mass spectrometry (MS/MS) methods for bioactive lipid profiling was employed. A previously validated UPLC-ESI-MS/MS method for profiling the endocannabinoid metabolome was used, while validation of an UPLC-ESI-MS/MS method for oxylipin analysis was performed with acceptable outcomes for a majority of the parameters according to the US Food and Drug Administration guidelines for linearity (0.9938 < R2 < 0.9996), limit of detection (0.0005-2.1 pg on column), limit of quantification (0.0005-4.2 pg on column), inter- and intraday accuracy (85-115%) and precision (< 5%), recovery (40-109%) and stability (40-105%). Forty-seven of fifty-two bioactive lipids were detected in plasma samples at fasting and in the postprandial state (0.5, 1, and 3 hours after the meal). Multivariate analysis showed a significant shift of bioactive lipid profiles in the postprandial state due to inclusion of dairy products in the diet, which was in line with univariate analysis revealing seven compounds (NAGly, 9-HODE, 13-oxo-ODE, 9(10)-EpOME, 12(13)-EpOME, 20-HETE, and 11,12-DHET) that were significantly different between background diets in the postprandial state (but not at fasting). The only change in baseline levels at fasting was displayed by TXB2. Furthermore, postprandial responsiveness was detected for seven compounds (POEA, SEA, 9(10)-DiHOME, 12(13)-DiHOME, 13-oxo-ODE, 9-HODE, and 13-HODE). Hence, the data confirm that the UPLC-ESI-MS/MS method performance was sufficient to detect i) a shift, in the current case most notably in the postprandial bioactive lipid metabolome, caused by changes in diet and ii) responsiveness to a challenge meal for a subset of the oxylipin and endocannabinoid metabolome. To summarize, we have shown proof-of-concept of our UPLC-ESI-MS/MS bioactive lipid protocols for the purpose of monitoring subtle shifts, and thereby useful to address lipid-mediated postprandial inflammation.

  18. Profiling the Oxylipin and Endocannabinoid Metabolome by UPLC-ESI-MS/MS in Human Plasma to Monitor Postprandial Inflammation

    PubMed Central

    Gouveia-Figueira, Sandra; Späth, Jana; Zivkovic, Angela M.; Nording, Malin L.

    2015-01-01

    Bioactive lipids, including oxylipins, endocannabinoids, and related compounds may function as specific biochemical markers of certain aspects of inflammation. However, the postprandial responsiveness of these compounds is largely unknown; therefore, changes in the circulating oxylipin and endocannabinoid metabolome in response to a challenge meal were investigated at six occasions in a subject who freely modified her usual diet. The dietary change, and especially the challenge meal itself, represented a modification of precursor fatty acid status, with expectedly subtle effects on bioactive lipid levels. To detect even the slightest alteration, highly sensitive ultra-performance liquid chromatography (UPLC) coupled to electrospray ionization (ESI) tandem mass spectrometry (MS/MS) methods for bioactive lipid profiling was employed. A previously validated UPLC-ESI-MS/MS method for profiling the endocannabinoid metabolome was used, while validation of an UPLC-ESI-MS/MS method for oxylipin analysis was performed with acceptable outcomes for a majority of the parameters according to the US Food and Drug Administration guidelines for linearity (0.9938 < R2 < 0.9996), limit of detection (0.0005–2.1 pg on column), limit of quantification (0.0005–4.2 pg on column), inter- and intraday accuracy (85–115%) and precision (< 5%), recovery (40–109%) and stability (40–105%). Forty-seven of fifty-two bioactive lipids were detected in plasma samples at fasting and in the postprandial state (0.5, 1, and 3 hours after the meal). Multivariate analysis showed a significant shift of bioactive lipid profiles in the postprandial state due to inclusion of dairy products in the diet, which was in line with univariate analysis revealing seven compounds (NAGly, 9-HODE, 13-oxo-ODE, 9(10)-EpOME, 12(13)-EpOME, 20-HETE, and 11,12-DHET) that were significantly different between background diets in the postprandial state (but not at fasting). The only change in baseline levels at fasting was displayed by TXB2. Furthermore, postprandial responsiveness was detected for seven compounds (POEA, SEA, 9(10)-DiHOME, 12(13)-DiHOME, 13-oxo-ODE, 9-HODE, and 13-HODE). Hence, the data confirm that the UPLC-ESI-MS/MS method performance was sufficient to detect i) a shift, in the current case most notably in the postprandial bioactive lipid metabolome, caused by changes in diet and ii) responsiveness to a challenge meal for a subset of the oxylipin and endocannabinoid metabolome. To summarize, we have shown proof-of-concept of our UPLC-ESI-MS/MS bioactive lipid protocols for the purpose of monitoring subtle shifts, and thereby useful to address lipid-mediated postprandial inflammation. PMID:26186333

  19. An Improved Pansharpening Method for Misaligned Panchromatic and Multispectral Data

    PubMed Central

    Jing, Linhai; Tang, Yunwei; Ding, Haifeng

    2018-01-01

    Numerous pansharpening methods were proposed in recent decades for fusing low-spatial-resolution multispectral (MS) images with high-spatial-resolution (HSR) panchromatic (PAN) bands to produce fused HSR MS images, which are widely used in various remote sensing tasks. The effect of misregistration between MS and PAN bands on quality of fused products has gained much attention in recent years. An improved method for misaligned MS and PAN imagery is proposed, through two improvements made on a previously published method named RMI (reduce misalignment impact). The performance of the proposed method was assessed by comparing with some outstanding fusion methods, such as adaptive Gram-Schmidt and generalized Laplacian pyramid. Experimental results show that the improved version can reduce spectral distortions of fused dark pixels and sharpen boundaries between different image objects, as well as obtain similar quality indexes with the original RMI method. In addition, the proposed method was evaluated with respect to its sensitivity to misalignments between MS and PAN bands. It is certified that the proposed method is more robust to misalignments between MS and PAN bands than the other methods. PMID:29439502

  20. An Improved Pansharpening Method for Misaligned Panchromatic and Multispectral Data.

    PubMed

    Li, Hui; Jing, Linhai; Tang, Yunwei; Ding, Haifeng

    2018-02-11

    Numerous pansharpening methods were proposed in recent decades for fusing low-spatial-resolution multispectral (MS) images with high-spatial-resolution (HSR) panchromatic (PAN) bands to produce fused HSR MS images, which are widely used in various remote sensing tasks. The effect of misregistration between MS and PAN bands on quality of fused products has gained much attention in recent years. An improved method for misaligned MS and PAN imagery is proposed, through two improvements made on a previously published method named RMI (reduce misalignment impact). The performance of the proposed method was assessed by comparing with some outstanding fusion methods, such as adaptive Gram-Schmidt and generalized Laplacian pyramid. Experimental results show that the improved version can reduce spectral distortions of fused dark pixels and sharpen boundaries between different image objects, as well as obtain similar quality indexes with the original RMI method. In addition, the proposed method was evaluated with respect to its sensitivity to misalignments between MS and PAN bands. It is certified that the proposed method is more robust to misalignments between MS and PAN bands than the other methods.

  1. Analysis of Carbamate Pesticides: Validation of Semi-Volatile Analysis by HPLC-MS/MS by EPA Method MS666

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Owens, J; Koester, C

    The Environmental Protection Agency's (EPA) Region 5 Chicago Regional Laboratory (CRL) developed a method for analysis of aldicarb, bromadiolone, carbofuran, oxamyl, and methomyl in water by high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS), titled Method EPA MS666. This draft standard operating procedure (SOP) was distributed to multiple EPA laboratories and to Lawrence Livermore National Laboratory, which was tasked to serve as a reference laboratory for EPA's Environmental Reference Laboratory Network (ERLN) and to develop and validate analytical procedures. The primary objective of this study was to validate and verify the analytical procedures described in MS666 for analysis of carbamatemore » pesticides in aqueous samples. The gathered data from this validation study will be used to: (1) demonstrate analytical method performance; (2) generate quality control acceptance criteria; and (3) revise the SOP to provide a validated method that would be available for use during a homeland security event. The data contained in this report will be compiled, by EPA CRL, with data generated by other EPA Regional laboratories so that performance metrics of Method EPA MS666 can be determined.« less

  2. The Exploration of Peptide Biomarkers in Malignant Pleural Effusion of Lung Cancer Using Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry

    PubMed Central

    Xu, Jing; Xu, Bin; Tang, Chuanhao; Li, Xiaoyan; Qin, Haifeng; Wang, Weixia; Wang, Hong; Wang, Zhongyuan; Li, Liangliang; Li, Zhihua; Gao, Hongjun

    2017-01-01

    Background. Diagnoses of malignant pleural effusion (MPE) are a crucial problem in clinics. In our study, we compared the peptide profiles of MPE and tuberculosis pleural effusion (TPE) to investigate the value of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) in diagnosis of MPE. Material and Methods. The 46 MPE and 32 TPE were randomly assigned to training set and validation set. Peptides were isolated by weak cation exchange magnetic beads and peaks in the m/z range of 800–10000 Da were analyzed. Comparing the peptide profile between 30 MPE and 22 TPE samples in training set by ClinProTools software, we screened the specific biomarkers and established a MALDI-TOF-MS classification of MPE. Finally, the other 16 MPE and 10 TPE were included to verify the model. We additionally determined carcinoembryonic antigen (CEA) in MPE and TPE samples using electrochemiluminescent immunoassay method. Results. Five peptide peaks (917.37 Da, 4469.39 Da, 1466.5 Da, 4585.21 Da, and 3216.87 Da) were selected to separate MPE and TPE by MALDI-TOF-MS. The sensitivity, specificity, and accuracy of the classification were 93.75%, 100%, and 96.15%, respectively, after blinded test. The sensitivity of CEA was significantly lower than MALDI-TOF-MS classification (P = 0.035). Conclusions. The results indicate MALDI-TOF-MS is a potential method for diagnosing MPE. PMID:28386154

  3. The Exploration of Peptide Biomarkers in Malignant Pleural Effusion of Lung Cancer Using Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry.

    PubMed

    Xu, Jing; Xu, Bin; Tang, Chuanhao; Li, Xiaoyan; Qin, Haifeng; Wang, Weixia; Wang, Hong; Wang, Zhongyuan; Li, Liangliang; Li, Zhihua; Gao, Hongjun; He, Kun; Liu, Xiaoqing

    2017-01-01

    Background . Diagnoses of malignant pleural effusion (MPE) are a crucial problem in clinics. In our study, we compared the peptide profiles of MPE and tuberculosis pleural effusion (TPE) to investigate the value of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) in diagnosis of MPE. Material and Methods . The 46 MPE and 32 TPE were randomly assigned to training set and validation set. Peptides were isolated by weak cation exchange magnetic beads and peaks in the m / z range of 800-10000 Da were analyzed. Comparing the peptide profile between 30 MPE and 22 TPE samples in training set by ClinProTools software, we screened the specific biomarkers and established a MALDI-TOF-MS classification of MPE. Finally, the other 16 MPE and 10 TPE were included to verify the model. We additionally determined carcinoembryonic antigen (CEA) in MPE and TPE samples using electrochemiluminescent immunoassay method. Results . Five peptide peaks (917.37 Da, 4469.39 Da, 1466.5 Da, 4585.21 Da, and 3216.87 Da) were selected to separate MPE and TPE by MALDI-TOF-MS. The sensitivity, specificity, and accuracy of the classification were 93.75%, 100%, and 96.15%, respectively, after blinded test. The sensitivity of CEA was significantly lower than MALDI-TOF-MS classification ( P = 0.035). Conclusions . The results indicate MALDI-TOF-MS is a potential method for diagnosing MPE.

  4. Quantitative detection of nitric oxide in exhaled human breath by extractive electrospray ionization mass spectrometry

    NASA Astrophysics Data System (ADS)

    Pan, Susu; Tian, Yong; Li, Ming; Zhao, Jiuyan; Zhu, Lanlan; Zhang, Wei; Gu, Haiwei; Wang, Haidong; Shi, Jianbo; Fang, Xiang; Li, Penghui; Chen, Huanwen

    2015-03-01

    Exhaled nitric oxide (eNO) is a useful biomarker of various physiological conditions, including asthma and other pulmonary diseases. Herein a fast and sensitive analytical method has been developed for the quantitative detection of eNO based on extractive electrospray ionization mass spectrometry (EESI-MS). Exhaled NO molecules selectively reacted with 2-phenyl-4, 4, 5, 5-tetramethylimidazoline-1-oxyl-3-oxide (PTIO) reagent, and eNO concentration was derived based on the EESI-MS response of 1-oxyl-2-phenyl-4, 4, 5, 5-tetramethylimidazoline (PTI) product. The method allowed quantification of eNO below ppb level (~0.02 ppbv) with a relative standard deviation (RSD) of 11.6%. In addition, eNO levels of 20 volunteers were monitored by EESI-MS over the time period of 10 hrs. Long-term eNO response to smoking a cigarette was recorded, and the observed time-dependent profile was discussed. This work extends the application of EESI-MS to small molecules (<30 Da) with low proton affinity and collision-induced dissociation efficiency, which are usually poorly visible by conventional ion trap mass spectrometers. Long-term quantitative profiling of eNO by EESI-MS opens new possibilities for the research of human metabolism and clinical diagnosis.

  5. A simple method to identify ether lipids in spermatozoa samples by MALDI-TOF mass spectrometry.

    PubMed

    Nimptsch, Ariane; Fuchs, Beate; Süß, Rosmarie; Zschörnig, Kristin; Jakop, Ulrike; Göritz, Frank; Schiller, Jürgen; Müller, Karin

    2013-08-01

    Plasmalogens (alkenylacyl glycerophospholipids) are important lipid constituents of many tissues and cells (e.g., selected spermatozoa). Since the molecular weights of plasmalogens overlap with that of diacyl- or alkyl acyl lipids, sophisticated mass spectrometry (MS; including MS/MS) analysis is normally used for the unequivocal identification of plasmalogens. We will show here that a simple matrix-assisted laser desorption/ionization time-of-flight mass spectrometer (without MS/MS capability) in combination with acidic hydrolysis and subsequent derivatization with 2,4-dinitrophenylhydrazine (DNPH) and/or digestion with phospholipase A2 (PLA2) is sufficient to determine the contributions of ether lipids in spermatozoa extracts. As neither diacyl nor alkylacyl lipids are sensitive to acids and do not react with DNPH, the comparison of the mass spectra before and after treatment with acids and/or DNPH addition readily provides unequivocal information about the plasmalogen content. Additionally, the released aldehydes are readily converted into the 2,4-dinitrophenylhydrazones and can be easily identified in the corresponding negative ion mass spectra. Finally, PLA2 digestion is very useful in confirming the presence of plasmalogens. The suggested method was validated by analyzing roe deer, bovine, boar, and domestic cat spermatozoa extracts and comparing the results with isolated phospholipids.

  6. Characterizing iron deposition in multiple sclerosis lesions using susceptibility weighted imaging

    PubMed Central

    Haacke, E. Mark; Makki, Malek; Ge, Yulin; Maheshwari, Megha; Sehgal, Vivek; Hu, Jiani; Selvan, Madeswaran; Wu, Zhen; Latif, Zahid; Xuan, Yang; Khan, Omar; Garbern, James; Grossman, Robert I.

    2009-01-01

    Purpose To investigate whether the variable forms of putative iron deposition seen with susceptibility weighted imaging (SWI) will lead to a set of multiple sclerosis (MS) lesion characteristics different than that seen in conventional MR imaging. Materials and Methods Twenty-seven clinically definite MS patients underwent brain scans using magnetic resonance imaging including: pre- and post-contrast T1-weighted, T2-weighted, FLAIR, and SWI at 1.5T, 3T and 4T. MS lesions were identified separately in each imaging sequence. Lesions identified in SWI were re-evaluated for their iron content using the SWI filtered phase images. Results There were a variety of new lesion characteristics identified by SWI and these were classified into six types. A total of 75 lesions were seen only with conventional imaging, 143 only with SWI and 204 by both. From the iron quantification measurements, a moderate linear correlation between signal intensity and iron content (phase) was established. Conclusion The amount of iron deposition in the brain may serve as a surrogate biomarker for different MS lesion characteristics. SWI showed many lesions missed by conventional methods and six different lesion characteristics. SWI was particularly effective at recognizing the presence of iron in MS lesions and in the basal ganglia and pulvinar thalamus. PMID:19243035

  7. Liquid chromatography and supercritical fluid chromatography as alternative techniques to gas chromatography for the rapid screening of anabolic agents in urine.

    PubMed

    Desfontaine, Vincent; Nováková, Lucie; Ponzetto, Federico; Nicoli, Raul; Saugy, Martial; Veuthey, Jean-Luc; Guillarme, Davy

    2016-06-17

    This work describes the development of two methods involving supported liquid extraction (SLE) sample treatment followed by ultra-high performance liquid chromatography or ultra-high performance supercritical fluid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS and UHPSFC-MS/MS) for the screening of 43 anabolic agents in human urine. After evaluating different stationary phases, a polar-embedded C18 and a diol columns were selected for UHPLC-MS/MS and UHPSFC-MS/MS, respectively. Sample preparation, mobile phases and MS conditions were also finely tuned to achieve highest selectivity, chromatographic resolution and sensitivity. Then, the performance of these two methods was compared to the reference routine procedure for steroid analyses in anti-doping laboratories, which combines liquid-liquid extraction (LLE) followed by gas chromatography coupled to tandem mass spectrometry (GC-MS/MS). For this purpose, urine samples spiked with the compounds of interest at five different concentrations were analyzed using the three analytical platforms. The retention and selectivity of the three techniques were very different, ensuring a good complementarity. However, the two new methods displayed numerous advantages. The overall procedure was much faster thanks to high throughput SLE sample treatment using 48-well plates and faster chromatographic analysis. Moreover, the highest sensitivity was attained using UHPLC-MS/MS with 98% of the doping agents detected at the lowest concentration level (0.1ng/mL), against 76% for UHPSFC-MS/MS and only 14% for GC-MS/MS. Finally, the weakest matrix effects were obtained with UHPSFC-MS/MS with 76% of the analytes displaying relative matrix effect between -20 and 20%, while the GC-MS/MS reference method displayed very strong matrix effects (over 100%) for all of the anabolic agents. Copyright © 2016 Elsevier B.V. All rights reserved.

  8. Determination of type B fumonisin mycotoxins in maize and maize-based products by liquid chromatography/tandem mass spectrometry using a QqQlinear ion trap mass spectrometer.

    PubMed

    Faberi, Angelo; Foglia, Patrizia; Pastorini, Elisabetta; Samperi, Roberto; Laganà, Aldo

    2005-01-01

    A sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method for determining the type B fumonisin mycotoxins in corn-based foodstuffs is described. Fumonisins FB1 and FB2 were extracted from a 1 g sample by homogenization with acetonitrile/water (75:25, v/v, 50 mmol/L formic acid, 25 mL final volume) and the extract was defatted on C18 phase. Volumes of 5 mL of crude extracts were cleaned up on Carbograph-4 cartridges. The final solution was analyzed by HPLC with electrospray ionization mass spectrometry in positive ion mode using multiple reaction monitoring with a QqQ linear ion trap mass spectrometer. Recoveries for spiked corn-based foodstuffs ranged from 91-105% (RSD% < or =8%), and method detection limits were < or =2 ng/g for FB1 and < or =1 ng/g for FB2. Two different spiking levels were tested (5000 and 100 ng/g for FB1, 1000 and 20 ng/g for FB2). Quantitation was achieved by an external calibration procedure using matrix-matched standards, with diclofenac added post-cleanup as internal standard for the LC/MS/MS analyses. Calibration curves showed linearity in the concentration range 0.005-5 ng/microL of final extract (0.992 < or = R2< or =0.995). Two other fumonisins, FB3 and FB4, were identified in naturally contaminated samples of corn meal using an information-dependent acquisition protocol that looped three experiments, including neutral loss scan, enhanced resolution scan, and enhanced product ion scan. FB3 and FB4 quantitation was estimated as peak area ratios relative to the FB2 response in view of the lack of both standards. This work also includes an application of the present LC/MS/MS method to some maize and maize-based product samples (corn meal, cornflakes and popcorn) collected from Italian stores. FB1 and FB2 contamination levels exceeding the European Union recommendation were found in 8 out of 15 corn meal samples.

  9. In vitro steroid profiling system for the evaluation of endocrine disruptors.

    PubMed

    Nakano, Yosuke; Yamashita, Toshiyuki; Okuno, Masashi; Fukusaki, Eiichiro; Bamba, Takeshi

    2016-09-01

    Endocrine disruptors (ED) are chemicals that affect various aspects of the endocrine system, often leading to the inhibition of steroidogenesis. Current chemical safety policies that restrict human exposure to such chemicals describe often time-consuming and costly methods for the evaluation of ED effects. We aimed to develop an effective tool for accurate phenotypic chemical toxicology studies. We developed an in vitro ED evaluation system using gas chromatography/mass spectrometry (GC/MS/MS) methods for metabolomic analysis of multi-marker profiles. Accounting for sample preparation and GC/MS/MS conditions, we established a screening method that allowed the simultaneous analysis of 17 steroids with good reproducibility and a linear calibration curve. Moreover, we applied the developed system to H295R human adrenocortical cells exposed to forskolin and prochloraz in accordance with the Organization for Economic Cooperation and Development (OECD) guidelines and observed dose-dependent variations in steroid profiles. While the OECD guidelines include only testosterone and 17β-estradiol, our system enabled a comprehensive and highly sensitive analysis of steroid profile alteration due to ED exposure. The application of our ED evaluation screen could be economical and provide novel insights into the hazards of ED exposure to the endocrine system. Copyright © 2016 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  10. Differential Mobility Spectrometry for Improved Selectivity in Hydrophilic Interaction Liquid Chromatography-Tandem Mass Spectrometry Analysis of Paralytic Shellfish Toxins

    NASA Astrophysics Data System (ADS)

    Beach, Daniel G.

    2017-08-01

    Paralytic shellfish toxins (PSTs) are neurotoxins produced by dinoflagellates and cyanobacteria that cause paralytic shellfish poisoning in humans. PST quantitation by LC-MS is challenging because of their high polarity, lability as gas-phase ions, and large number of potentially interfering analogues. Differential mobility spectrometry (DMS) has the potential to improve the performance of LC-MS methods for PSTs in terms of selectivity and limits of detection. This work describes a comprehensive investigation of the separation of 16 regulated PSTs by DMS and the development of highly selective LC-DMS-MS methods for PST quantitation. The effects of all DMS parameters on the separation of PSTs from one another were first investigated in detail. The labile nature of 11α-gonyautoxin epimers gave unique insight into fragmentation of labile analytes before, during, and after the DMS analyzer. Two sets of DMS parameters were identified that either optimized the resolution of PSTs from one another or transmitted them at a limited number of compensation voltage (CV) values corresponding to structural subclasses. These were used to develop multidimensional LC-DMS-MS/MS methods using existing HILIC-MS/MS parameters. In both cases, improved selectivity was observed when using DMS, and the quantitative capabilities of a rapid UPLC-DMS-MS/MS method were evaluated. Limits of detection of the developed method were similar to those without DMS, and differences were highly analyte-dependant. Analysis of shellfish matrix reference materials showed good agreement with established methods. The developed methods will be useful in cases where specific matrix interferences are encountered in the LC-MS/MS analysis of PSTs in complex biological samples.

  11. Identification of chemical markers in Cordyceps sinensis by HPLC-MS/MS.

    PubMed

    Hu, Hankun; Xiao, Ling; Zheng, Baogen; Wei, Xin; Ellis, Alexis; Liu, Yi-Ming

    2015-10-01

    Authentication and quality assessment of Cordyceps sinensis, a precious and pricey natural product that offers a variety of health benefits, is highly significant. To identify effective chemical markers, authentic C. sinensis was thoroughly screened by using HPLC-MS/MS. In addition to many previously reported ingredients, two glycosides, i.e., cyclo-Ala-Leu-rhamnose and Phe-o-glucose, were detected for the first time in this material. Six ingredients detected, including cordycepin, D-mannitol, Phe, Phe-o-glucose, cyclo-Gly-Pro, and cyclo-Ala-Leu-rhamnose, were selected as a collection of chemical markers. An HPLC-MS/MS method was developed to simultaneously quantify them with sensitivity and specificity. The method had limits of detection ranging from 0.008 μg mL(-1) for cordycepin to 0.75 μg mL(-1) for cyclo-Gly-Pro. Recovery was found between 96 and 103 % in all tests. To evaluate the effectiveness of the marker collection proposed, five authentic C. sinensis samples and five samples of its substitutes were analyzed. Cordycepin, D-mannitol, and Phe were found present in all samples. The contents ranged from 0.0076 to 0.029 % (w/w) for cordycepin, 0.33 to 18.9 % for mannitol, and 0.0013 to 0.642 % for Phe. Interestingly, the two glycosides, Phe-o-glucose and cyclo-Ala-Leu-rhamnose, were detected only in authentic C. sinensis samples. These results indicated that the proposed protocol based on HPLC-MS/MS quantification of the markers might have a great potential in authentication and quality assessment of C. sinensis. Graphical abstract Chemical markers of C. sinensis identified in this work.

  12. Determination of rivaroxaban in patient’s plasma samples by anti-Xa chromogenic test associated to High Performance Liquid Chromatography tandem Mass Spectrometry (HPLC-MS/MS)

    PubMed Central

    Derogis, Priscilla Bento Matos; Sanches, Livia Rentas; de Aranda, Valdir Fernandes; Colombini, Marjorie Paris; Mangueira, Cristóvão Luis Pitangueira; Katz, Marcelo; Faulhaber, Adriana Caschera Leme; Mendes, Claudio Ernesto Albers; Ferreira, Carlos Eduardo dos Santos; França, Carolina Nunes; Guerra, João Carlos de Campos

    2017-01-01

    Rivaroxaban is an oral direct factor Xa inhibitor, therapeutically indicated in the treatment of thromboembolic diseases. As other new oral anticoagulants, routine monitoring of rivaroxaban is not necessary, but important in some clinical circumstances. In our study a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was validated to measure rivaroxaban plasmatic concentration. Our method used a simple sample preparation, protein precipitation, and a fast chromatographic run. It was developed a precise and accurate method, with a linear range from 2 to 500 ng/mL, and a lower limit of quantification of 4 pg on column. The new method was compared to a reference method (anti-factor Xa activity) and both presented a good correlation (r = 0.98, p < 0.001). In addition, we validated hemolytic, icteric or lipemic plasma samples for rivaroxaban measurement by HPLC-MS/MS without interferences. The chromogenic and HPLC-MS/MS methods were highly correlated and should be used as clinical tools for drug monitoring. The method was applied successfully in a group of 49 real-life patients, which allowed an accurate determination of rivaroxaban in peak and trough levels. PMID:28170419

  13. DBS-LC-MS/MS assay for caffeine: validation and neonatal application.

    PubMed

    Bruschettini, Matteo; Barco, Sebastiano; Romantsik, Olga; Risso, Francesco; Gennai, Iulian; Chinea, Benito; Ramenghi, Luca A; Tripodi, Gino; Cangemi, Giuliana

    2016-09-01

    DBS might be an appropriate microsampling technique for therapeutic drug monitoring of caffeine in infants. Nevertheless, its application presents several issues that still limit its use. This paper describes a validated DBS-LC-MS/MS method for caffeine. The results of the method validation showed an hematocrit dependence. In the analysis of 96 paired plasma and DBS clinical samples, caffeine levels measured in DBS were statistically significantly lower than in plasma but the observed differences were independent from hematocrit. These results clearly showed the need for extensive validation with real-life samples for DBS-based methods. DBS-LC-MS/MS can be considered to be a good alternative to traditional methods for therapeutic drug monitoring or PK studies in preterm infants.

  14. Urinary Amino Acid Analysis: A Comparison of iTRAQ®-LC-MS/MS, GC-MS, and Amino Acid Analyzer

    PubMed Central

    Kaspar, Hannelore; Dettmer, Katja; Chan, Queenie; Daniels, Scott; Nimkar, Subodh; Daviglus, Martha L.; Stamler, Jeremiah; Elliott, Paul; Oefner, Peter J.

    2009-01-01

    Urinary amino acid analysis is typically done by cation-exchange chromatography followed by post-column derivatization with ninhydrin and UV detection. This method lacks throughput and specificity. Two recently introduced stable isotope ratio mass spectrometric methods promise to overcome those shortcomings. Using two blinded sets of urine replicates and a certified amino acid standard, we compared the precision and accuracy of gas chromatography/mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) of propyl chloroformate and iTRAQ® derivatized amino acids, respectively, to conventional amino acid analysis. The GC-MS method builds on the direct derivatization of amino acids in diluted urine with propyl chloroformate, GC separation and mass spectrometric quantification of derivatives using stable isotope labeled standards. The LC-MS/MS method requires prior urinary protein precipitation followed by labeling of urinary and standard amino acids with iTRAQ® tags containing different cleavable reporter ions distinguishable by MS/MS fragmentation. Means and standard deviations of percent technical error (%TE) computed for 20 amino acids determined by amino acid analyzer, GC-MS, and iTRAQ®-LC-MS/MS analyses of 33 duplicate and triplicate urine specimens were 7.27±5.22, 21.18±10.94, and 18.34±14.67, respectively. Corresponding values for 13 amino acids determined in a second batch of 144 urine specimens measured in duplicate or triplicate were 8.39±5.35, 6.23±3.84, and 35.37±29.42. Both GC-MS and iTRAQ®-LC-MS/MS are suited for high-throughput amino acid analysis, with the former offering at present higher reproducibility and completely automated sample pretreatment, while the latter covers more amino acids and related amines. PMID:19481989

  15. Urinary amino acid analysis: a comparison of iTRAQ-LC-MS/MS, GC-MS, and amino acid analyzer.

    PubMed

    Kaspar, Hannelore; Dettmer, Katja; Chan, Queenie; Daniels, Scott; Nimkar, Subodh; Daviglus, Martha L; Stamler, Jeremiah; Elliott, Paul; Oefner, Peter J

    2009-07-01

    Urinary amino acid analysis is typically done by cation-exchange chromatography followed by post-column derivatization with ninhydrin and UV detection. This method lacks throughput and specificity. Two recently introduced stable isotope ratio mass spectrometric methods promise to overcome those shortcomings. Using two blinded sets of urine replicates and a certified amino acid standard, we compared the precision and accuracy of gas chromatography/mass spectrometry (GC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS) of propyl chloroformate and iTRAQ derivatized amino acids, respectively, to conventional amino acid analysis. The GC-MS method builds on the direct derivatization of amino acids in diluted urine with propyl chloroformate, GC separation and mass spectrometric quantification of derivatives using stable isotope labeled standards. The LC-MS/MS method requires prior urinary protein precipitation followed by labeling of urinary and standard amino acids with iTRAQ tags containing different cleavable reporter ions distinguishable by MS/MS fragmentation. Means and standard deviations of percent technical error (%TE) computed for 20 amino acids determined by amino acid analyzer, GC-MS, and iTRAQ-LC-MS/MS analyses of 33 duplicate and triplicate urine specimens were 7.27+/-5.22, 21.18+/-10.94, and 18.34+/-14.67, respectively. Corresponding values for 13 amino acids determined in a second batch of 144 urine specimens measured in duplicate or triplicate were 8.39+/-5.35, 6.23+/-3.84, and 35.37+/-29.42. Both GC-MS and iTRAQ-LC-MS/MS are suited for high-throughput amino acid analysis, with the former offering at present higher reproducibility and completely automated sample pretreatment, while the latter covers more amino acids and related amines.

  16. Detection of in utero cannabis exposure by umbilical cord analysis.

    PubMed

    Kim, Jiyoung; de Castro, Ana; Lendoiro, Elena; Cruz-Landeira, Angelines; López-Rivadulla, Manuel; Concheiro, Marta

    2018-04-01

    According to the 2014 National Survey on Drug Use and Health, 5.3% of pregnant women smoked marijuana in the past month. This prevalence is expected to increase as a growing number of states and countries are now considering legalization. Although the umbilical cord is becoming a useful objective tool to detect in utero drug exposure, currently data about analytical methods and its utility to detect cannabis exposure are scarce. The objective of this work was to develop a method for the determination of Δ 9 -tetrahydrocannabinol (THC), 11-hydroxyTHC (THC-OH), 11-nor-9-carboxy-THC (THCCOOH), 8-β-11-dihydroxyTHC (THC-diOH), THC and THCCOOH glucuronides, and cannabidiol (CBD) in the umbilical cord by liquid chromatography-tandem mass spectrometry (LC-MS/MS) with dual ionization source. Umbilical cord samples (0.5 g) were homogenized in methanol and extracted by solid-phase extraction. Reversed-phase chromatographic separation was performed in 14 minutes, and 2 transitions per analyte were monitored in multiple reaction monitoring mode. Method validation included linearity (1-10 to 20-200 ng/g), precision (4.1%-23.4%), accuracy (87.5%-111.4%), matrix effect (-54.8% to -5.8%), extraction efficiency (25%-45.6%), limits of detection and quantification (1-10 ng/g), and endogenous (n = 5) or exogenous interferences (not detected). The method was applied to 13 authentic samples from cannabis-exposed newborns, which meconium samples had tested positive for cannabis. Twelve cord specimens tested positive for THCCOOH-glucuronide (1.6-19.1 ng/g). We developed and validated a specific and sensitive method for the simultaneous determination of THC, its metabolites, including THC and THCCOOH glucuronides, and CBD in umbilical cord samples by LC-MS/MS. The analysis of authentic samples showed the usefulness of umbilical cord to detect cannabis in utero exposure. Copyright © 2017 John Wiley & Sons, Ltd.

  17. Optimization of mass spectrometric parameters improve the identification performance of capillary zone electrophoresis for single-shot bottom-up proteomics analysis.

    PubMed

    Zhang, Zhenbin; Dovichi, Norman J

    2018-02-25

    The effects of MS1 injection time, MS2 injection time, dynamic exclusion time, intensity threshold, and isolation width were investigated on the numbers of peptide and protein identifications for single-shot bottom-up proteomics analysis using CZE-MS/MS analysis of a Xenopus laevis tryptic digest. An electrokinetically pumped nanospray interface was used to couple a linear-polyacrylamide coated capillary to a Q Exactive HF mass spectrometer. A sensitive method that used a 1.4 Th isolation width, 60,000 MS2 resolution, 110 ms MS2 injection time, and a top 7 fragmentation produced the largest number of identifications when the CZE loading amount was less than 100 ng. A programmable autogain control method (pAGC) that used a 1.4 Th isolation width, 15,000 MS2 resolution, 110 ms MS2 injection time, and top 10 fragmentation produced the largest number of identifications for CZE loading amounts greater than 100 ng; 7218 unique peptides and 1653 protein groups were identified from 200 ng by using the pAGC method. The effect of mass spectrometer conditions on the performance of UPLC-MS/MS was also investigated. A fast method that used a 1.4 Th isolation width, 30,000 MS2 resolution, 45 ms MS2 injection time, and top 12 fragmentation produced the largest number of identifications for 200 ng UPLC loading amount (6025 unique peptides and 1501 protein groups). This is the first report where the identification number for CZE surpasses that of the UPLC at the 200 ng loading level. However, more peptides (11476) and protein groups (2378) were identified by using UPLC-MS/MS when the sample loading amount was increased to 2 μg with the fast method. To exploit the fast scan speed of the Q-Exactive HF mass spectrometer, higher sample loading amounts are required for single-shot bottom-up proteomics analysis using CZE-MS/MS. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Determination of T-2 toxin, HT-2 toxin, and three other type A trichothecenes in layer feed by high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS)--comparison of two sample preparation methods.

    PubMed

    Bernhardt, Katrin; Valenta, Hana; Kersten, Susanne; Humpf, Hans-Ulrich; Dänicke, Sven

    2016-05-01

    A sensitive method for the simultaneous determination of T-2 toxin, HT-2 toxin, neosolaniol, T-2 triol, and T-2 tetraol in layer feed using high-performance liquid chromatography coupled to triple quadrupole mass spectrometry in the positive ionization mode (LC-ESI-MS/MS) is described. Two fast and easy clean-up methods-with BondElut Mycotoxin and MycoSep 227 columns, respectively-were tested. The separation of the toxins was conducted on a Pursuit XRs Ultra 2.8 HPLC column using 0.13 mM ammonium acetate as eluent A and methanol as eluent B. Detection of the mycotoxins was carried out in the multiple reaction monitoring (MRM) mode using ammonium adducts as precursor ions. Quantification of all analytes was performed with d3-T-2 toxin as an internal standard. The clean-up method with MycoSep 227 columns gave slightly better results for layer feed compared to the method using BondElut Mycotoxin columns (MycoSep 227: recovery between 50 and 63%, BondElut Mycotoxin: recovery between 32 and 67%) and was therefore chosen as the final method. The limits of detection ranged between 0.9 and 7.5 ng/g depending on the mycotoxin. The method was developed for the analysis of layer feed used at carry-over experiments with T-2 toxin in laying hens. For carry-over experiments, it is necessary that the method includes not only T-2 toxin but also the potential metabolites in animal tissues HT-2 toxin, neosolaniol, T-2 triol, and T-2 tetraol which could naturally occur in cereals used as feed stuff as well.

  19. Orthogonal Comparison of GC-MS and 1H NMR Spectroscopy for Short Chain Fatty Acid Quantitation.

    PubMed

    Cai, Jingwei; Zhang, Jingtao; Tian, Yuan; Zhang, Limin; Hatzakis, Emmanuel; Krausz, Kristopher W; Smith, Philip B; Gonzalez, Frank J; Patterson, Andrew D

    2017-08-01

    Short chain fatty acids (SCFAs) are important regulators of host physiology and metabolism and may contribute to obesity and associated metabolic diseases. Interest in SCFAs has increased in part due to the recognized importance of how production of SCFAs by the microbiota may signal to the host. Therefore, reliable, reproducible, and affordable methods for SCFA profiling are required for accurate identification and quantitation. In the current study, four different methods for SCFA (acetic acid, propionic acid, and butyric acid) extraction and quantitation were compared using two independent platforms including gas chromatography coupled with mass spectrometry (GC-MS) and 1 H nuclear magnetic resonance (NMR) spectroscopy. Sensitivity, recovery, repeatability, matrix effect, and validation using mouse fecal samples were determined across all methods. The GC-MS propyl esterification method exhibited superior sensitivity for acetic acid and butyric acid measurement (LOD < 0.01 μg mL -1 , LOQ < 0.1 μg mL -1 ) and recovery accuracy (99.4%-108.3% recovery rate for 100 μg mL -1 SCFA mixed standard spike in and 97.8%-101.8% recovery rate for 250 μg mL -1 SCFAs mixed standard spike in). NMR methods by either quantitation relative to an internal standard or quantitation using a calibration curve yielded better repeatability and minimal matrix effects compared to GC-MS methods. All methods generated good calibration curve linearity (R 2 > 0.99) and comparable measurement of fecal SCFA concentration. Lastly, these methods were used to quantitate fecal SCFAs obtained from conventionally raised (CONV-R) and germ free (GF) mice. Results from global metabolomic analysis of feces generated by 1 H NMR and bomb calorimetry were used to further validate these approaches.

  20. Maternal satisfaction as an outcome criterion in research on labor analgesia: data analysis from the recent literature.

    PubMed

    Dualé, Christian; Nicolas-Courbon, Aurélie; Gerbaud, Laurent; Lemery, Didier; Bonnin, Martine; Pereira, Bruno

    2015-03-01

    To investigate whether maternal satisfaction (MS) is taken into consideration as an outcome criterion in clinical research on analgesia for labor. A systematic review of articles reporting analgesia for labor from a panel of 17 influential journals was undertaken. A total of 116 articles were analyzed, including 282 within-study groups. The scope of MS, the type of outcome measure used, and the time of measurement were noted. Each available observation was assigned an ordinal value of MS (ordMS), according to data distribution. The factors influencing ordMS were identified by multivariable analysis. The methods used to assess MS were very variable, even within the different measurement tools reported. The weighted distribution of ordMS was 17.8%, 21.8%, 31.2%, and 29.3% for levels "poor," "fair," "good," and "excellent," respectively. In comparative studies, statistical differences for analgesia were related to statistical differences for MS (P<0.0001), but only the negative predictive value was high (0.87). Power to detect a difference in MS between treatment groups was low in general, but it influenced reporting of a significant difference for MS (P<0.0001). The obstetrical factors influencing ordMS were: the body mass index, the initial cervical dilatation, and the within-study percentage of nulliparous women. The techniques alternative to epidural analgesia negatively influenced ordMS. A standard and validated tool to assess MS in clinical research on analgesia for labor is still to be developed. Power should be improved by acting on sample sizes or sensitivity of the outcome.

Top