Digital photography and transparency-based methods for measuring wound surface area.
Bhedi, Amul; Saxena, Atul K; Gadani, Ravi; Patel, Ritesh
2013-04-01
To compare and determine a credible method of measurement of wound surface area by linear, transparency, and photographic methods for monitoring progress of wound healing accurately and ascertaining whether these methods are significantly different. From April 2005 to December 2006, 40 patients (30 men, 5 women, 5 children) admitted to the surgical ward of Shree Sayaji General Hospital, Baroda, had clean as well as infected wound following trauma, debridement, pressure sore, venous ulcer, and incision and drainage. Wound surface areas were measured by these three methods (linear, transparency, and photographic methods) simultaneously on alternate days. The linear method is statistically and significantly different from transparency and photographic methods (P value <0.05), but there is no significant difference between transparency and photographic methods (P value >0.05). Photographic and transparency methods provided measurements of wound surface area with equivalent result and there was no statistically significant difference between these two methods.
Evaluation of a visual layering methodology for colour coding control room displays.
Van Laar, Darren; Deshe, Ofer
2002-07-01
Eighteen people participated in an experiment in which they were asked to search for targets on control room like displays which had been produced using three different coding methods. The monochrome coding method displayed the information in black and white only, the maximally discriminable method contained colours chosen for their high perceptual discriminability, the visual layers method contained colours developed from psychological and cartographic principles which grouped information into a perceptual hierarchy. The visual layers method produced significantly faster search times than the other two coding methods which did not differ significantly from each other. Search time also differed significantly for presentation order and for the method x order interaction. There was no significant difference between the methods in the number of errors made. Participants clearly preferred the visual layers coding method. Proposals are made for the design of experiments to further test and develop the visual layers colour coding methodology.
Accuracy of tree diameter estimation from terrestrial laser scanning by circle-fitting methods
NASA Astrophysics Data System (ADS)
Koreň, Milan; Mokroš, Martin; Bucha, Tomáš
2017-12-01
This study compares the accuracies of diameter at breast height (DBH) estimations by three initial (minimum bounding box, centroid, and maximum distance) and two refining (Monte Carlo and optimal circle) circle-fitting methods The circle-fitting algorithms were evaluated in multi-scan mode and a simulated single-scan mode on 157 European beech trees (Fagus sylvatica L.). DBH measured by a calliper was used as reference data. Most of the studied circle-fitting algorithms significantly underestimated the mean DBH in both scanning modes. Only the Monte Carlo method in the single-scan mode significantly overestimated the mean DBH. The centroid method proved to be the least suitable and showed significantly different results from the other circle-fitting methods in both scanning modes. In multi-scan mode, the accuracy of the minimum bounding box method was not significantly different from the accuracies of the refining methods The accuracy of the maximum distance method was significantly different from the accuracies of the refining methods in both scanning modes. The accuracy of the Monte Carlo method was significantly different from the accuracy of the optimal circle method in only single-scan mode. The optimal circle method proved to be the most accurate circle-fitting method for DBH estimation from point clouds in both scanning modes.
Aghdam, Rosa; Baghfalaki, Taban; Khosravi, Pegah; Saberi Ansari, Elnaz
2017-12-01
Deciphering important genes and pathways from incomplete gene expression data could facilitate a better understanding of cancer. Different imputation methods can be applied to estimate the missing values. In our study, we evaluated various imputation methods for their performance in preserving significant genes and pathways. In the first step, 5% genes are considered in random for two types of ignorable and non-ignorable missingness mechanisms with various missing rates. Next, 10 well-known imputation methods were applied to the complete datasets. The significance analysis of microarrays (SAM) method was applied to detect the significant genes in rectal and lung cancers to showcase the utility of imputation approaches in preserving significant genes. To determine the impact of different imputation methods on the identification of important genes, the chi-squared test was used to compare the proportions of overlaps between significant genes detected from original data and those detected from the imputed datasets. Additionally, the significant genes are tested for their enrichment in important pathways, using the ConsensusPathDB. Our results showed that almost all the significant genes and pathways of the original dataset can be detected in all imputed datasets, indicating that there is no significant difference in the performance of various imputation methods tested. The source code and selected datasets are available on http://profiles.bs.ipm.ir/softwares/imputation_methods/. Copyright © 2017. Production and hosting by Elsevier B.V.
2013-05-28
span of 1-250 ng DDT. Furthermore, laboratory and field experiments utilizing this method confirmed that significant DDT concentration differences ... different between the two sample introduction methods when comparing the same DDT mass which may be due to differences in the precision of split...degradation of DDT was significantly different between the liquid and TD methods (t-test; p < 0.001). For TD analyses the relative percent
Knösel, Michael; Attin, Rengin; Jung, Klaus; Brunner, Edgar; Kubein-Meesenburg, Dietmar; Attin, Thomas
2009-04-01
To evaluate the concordance and repeatability of two in vivo methods for dental color assessment and to clarify the influence of different ambient light conditions and subject's head position on the assessed color variables. Color assessments were performed by two examiners on 16 arbitrarily selected subjects under two different, standardized conditions of illumination and at two different standardized head angulations. CIE (L*a*b*) data for upper and lower central incisors were recorded in two different ways: (1) by an intra-oral contact dental colorimeter and (2) by processing digital images for performing color calculation using Adobe Photoshop software. The influence of the different ambient conditions on both methods, as well as the concordance of measurements was analyzed statistically using several mixed linear models. Ambient light as a single factor had no significant influence on maxillary L*, a* and b* values, but it did have an effect on mandible assessments. Head angulation variation resulted in significant L* value differences using the photo method. The operator had a significant influence on values a* and b* for the photo method and on a* values for the colorimeter method. In fully lit ambient condition, the operator had a significant influence on the segregated L*, a*, and b* values. With dimmed lights, head angulation became significant, but not the operator. Evaluation of segregated L* values was error prone in both methods. Comparing both methods, deltaE values did not exceed 2.85 units, indicating that color differences between methods and recorded under varying ambient conditions were well below the sensitivity of the naked eye.
Visschers, Naomi C A; Hulzebos, Erik H; van Brussel, Marco; Takken, Tim
2015-11-01
The ventilatory anaerobic threshold (VAT) is an important method to assess the aerobic fitness in patients with cardiopulmonary disease. Several methods exist to determine the VAT; however, there is no consensus which of these methods is the most accurate. To compare four different non-invasive methods for the determination of the VAT via respiratory gas exchange analysis during a cardiopulmonary exercise test (CPET). A secondary objective is to determine the interobserver reliability of the VAT. CPET data of 30 children diagnosed with either cystic fibrosis (CF; N = 15) or with a surgically corrected dextro-transposition of the great arteries (asoTGA; N = 15) were included. No significant differences were found between conditions or among testers. The RER = 1 method differed the most compared to the other methods, showing significant higher results in all six variables. The PET-O2 method differed significantly on five of six and four of six exercise variables with the V-slope method and the VentEq method, respectively. The V-slope and the VentEq method differed significantly on one of six exercise variables. Ten of thirteen ICCs that were >0.80 had a 95% CI > 0.70. The RER = 1 method and the V-slope method had the highest number of significant ICCs and 95% CIs. The V-slope method, the ventilatory equivalent method and the PET-O2 method are comparable and reliable methods to determine the VAT during CPET in children with CF or asoTGA. © 2014 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ji, Changyoon, E-mail: changyoon@yonsei.ac.kr; Hong, Taehoon, E-mail: hong7@yonsei.ac.kr
Previous studies have proposed several methods for integrating characterized environmental impacts as a single index in life cycle assessment. Each of them, however, may lead to different results. This study presents internal and external normalization methods, weighting factors proposed by panel methods, and a monetary valuation based on an endpoint life cycle impact assessment method as the integration methods. Furthermore, this study investigates the differences among the integration methods and identifies the causes of the differences through a case study in which five elementary school buildings were used. As a result, when using internal normalization with weighting factors, the weightingmore » factors had a significant influence on the total environmental impacts whereas the normalization had little influence on the total environmental impacts. When using external normalization with weighting factors, the normalization had more significant influence on the total environmental impacts than weighing factors. Due to such differences, the ranking of the five buildings varied depending on the integration methods. The ranking calculated by the monetary valuation method was significantly different from that calculated by the normalization and weighting process. The results aid decision makers in understanding the differences among these integration methods, and, finally, help them select the method most appropriate for the goal at hand.« less
Brooks, Christine; Vickers, Amy Manning; Aryal, Subhash
2013-04-01
The objective of this study was to compare the differences in lipid loss from 24 samples of banked donor human milk (DHM) among 3 feeding methods: DHM given by syringe pump over 1 hour, 2 hours, and by bolus/gravity gavage. Comparative, descriptive. There were no human subjects. Twenty-four samples of 8 oz of DHM were divided into four 60-mL aliquots. Timed feedings were given by Medfusion 2001 syringe pumps with syringes connected to narrow-lumened extension sets designed for enteral feedings and connected to standard silastic enteral feeding tubes. Gravity feedings were given using the identical syringes connected to the same silastic feeding tubes. All aliquots were analyzed with the York Dairy Analyzer. Univariate repeated-measures analyses of variance were used for the omnibus testing for overall differences between the feeding methods. Lipid content expressed as grams per deciliter at the end of each feeding method was compared with the prefed control samples using the Dunnett's test. The Tukey correction was used for other pairwise multiple comparisons. The univariate repeated-measures analysis of variance conducted to test for overall differences between feeding methods showed a significant difference between the methods (F = 58.57, df = 3, 69, P < .0001). Post hoc analysis using the Dunnett's approach revealed that there was a significant difference in fat content between the control sample and the 1-hour and 2-hours feeding methods (P < .0001), but we did not find any significant difference in fat content between the control and the gravity feeding methods (P = .3296). Pairwise comparison using the Tukey correction revealed a significant difference between both gravity and 1-hour feeding methods (P < .0001), and gravity and 2-hour feeding method (P < .0001). There was no significant difference in lipid content between the 1-hour and 2-hour feeding methods (P = .2729). Unlike gravity feedings, the timed feedings resulted in a statistically significant loss of fat as compared with their controls. These findings should raise questions about how those infants in the neonatal intensive care unit are routinely gavage fed.
Lu, Tzong-Shi; Yiao, Szu-Yu; Lim, Kenneth; Jensen, Roderick V; Hsiao, Li-Li
2010-07-01
The identification of differences in protein expression resulting from methodical variations is an essential component to the interpretation of true, biologically significant results. We used the Lowry and Bradford methods- two most commonly used methods for protein quantification, to assess whether differential protein expressions are a result of true biological or methodical variations. MATERIAL #ENTITYSTARTX00026; Differential protein expression patterns was assessed by western blot following protein quantification by the Lowry and Bradford methods. We have observed significant variations in protein concentrations following assessment with the Lowry versus Bradford methods, using identical samples. Greater variations in protein concentration readings were observed over time and in samples with higher concentrations, with the Bradford method. Identical samples quantified using both methods yielded significantly different expression patterns on Western blot. We show for the first time that methodical variations observed in these protein assay techniques, can potentially translate into differential protein expression patterns, that can be falsely taken to be biologically significant. Our study therefore highlights the pivotal need to carefully consider methodical approaches to protein quantification in techniques that report quantitative differences.
[The Misgav-Ladach method for cesarean section compared to the Pfannenstiel technique].
Studziński, Zbigniew
2002-08-01
The aim of the study was to evaluate the outcome of two different methods of cesarean section. To determine whether the Misgav-Ladach caesarean technique can offer benefits when compared with conventional Pfannenstiel caesarean section technique. This study describes operative details and the postoperative course of 110 patients who underwent caesarean section in May 2000 to December 2000 in Department of Gynecology and Obstetrics in Regional Hospital in Slupsk, Poland. One group (50 women) was operated with the Misgav-Ladach method for caesarean section and the other group (60 women) with Pfannenstiel method. Operating time was significantly different between the two methods, with an average of 20.2 minutes with the Misgav-Ladach method and 47.3 minutes with the Pfannenstiel method (p < 0.001). Time of child delivery was with average 1.1 minutes with the Misgav-Ladach method and 3.8 minutes with the Pfannenstiel method (p < 0.001). The amount of blood loss different significantly, with 336 ml and 483 ml respectively (p < 0.001). No significant difference was found in Apgar scores. No difference was found in overall postoperative complications, wound infection, febrile illness, febrile morbidity, wound dehiscence affected by the new technique. Significantly less suture material was used during Misgav-Ladach caesarean section compared to Pfannenstiel technique (p < 0.001). The Misgav-Ladach method of caesarean section has advantages over the Pfannenstiel technique by being significantly quicker to perform, with the reduced amounts of bleeding and suture material. The women were satisfied with the appearance of their scars. In this study no negative effects of the new operation technique were discovered.
Testing the Difference of Correlated Agreement Coefficients for Statistical Significance
ERIC Educational Resources Information Center
Gwet, Kilem L.
2016-01-01
This article addresses the problem of testing the difference between two correlated agreement coefficients for statistical significance. A number of authors have proposed methods for testing the difference between two correlated kappa coefficients, which require either the use of resampling methods or the use of advanced statistical modeling…
Khajouei, Reza; Zahiri Esfahani, Misagh; Jahani, Yunes
2017-04-01
There are several user-based and expert-based usability evaluation methods that may perform differently according to the context in which they are used. The objective of this study was to compare 2 expert-based methods, heuristic evaluation (HE) and cognitive walkthrough (CW), for evaluating usability of health care information systems. Five evaluators independently evaluated a medical office management system using HE and CW. We compared the 2 methods in terms of the number of identified usability problems, their severity, and the coverage of each method. In total, 156 problems were identified using the 2 methods. HE identified a significantly higher number of problems related to the "satisfaction" attribute ( P = .002). The number of problems identified using CW concerning the "learnability" attribute was significantly higher than those identified using HE ( P = .005). There was no significant difference between the number of problems identified by HE, based on different usability attributes ( P = .232). Results of CW showed a significant difference between the number of problems related to usability attributes ( P < .0001). The average severity of problems identified using CW was significantly higher than that of HE ( P < .0001). This study showed that HE and CW do not differ significantly in terms of the number of usability problems identified, but they differ based on the severity of problems and the coverage of some usability attributes. The results suggest that CW would be the preferred method for evaluating systems intended for novice users and HE for users who have experience with similar systems. However, more studies are needed to support this finding. © The Author 2016. Published by Oxford University Press on behalf of the American Medical Informatics Association. All rights reserved. For Permissions, please email: journals.permissions@oup.com
Virtual and stereoscopic anatomy: when virtual reality meets medical education.
de Faria, Jose Weber Vieira; Teixeira, Manoel Jacobsen; de Moura Sousa Júnior, Leonardo; Otoch, Jose Pinhata; Figueiredo, Eberval Gadelha
2016-11-01
OBJECTIVE The authors sought to construct, implement, and evaluate an interactive and stereoscopic resource for teaching neuroanatomy, accessible from personal computers. METHODS Forty fresh brains (80 hemispheres) were dissected. Images of areas of interest were captured using a manual turntable and processed and stored in a 5337-image database. Pedagogic evaluation was performed in 84 graduate medical students, divided into 3 groups: 1 (conventional method), 2 (interactive nonstereoscopic), and 3 (interactive and stereoscopic). The method was evaluated through a written theory test and a lab practicum. RESULTS Groups 2 and 3 showed the highest mean scores in pedagogic evaluations and differed significantly from Group 1 (p < 0.05). Group 2 did not differ statistically from Group 3 (p > 0.05). Size effects, measured as differences in scores before and after lectures, indicate the effectiveness of the method. ANOVA results showed significant difference (p < 0.05) between groups, and the Tukey test showed statistical differences between Group 1 and the other 2 groups (p < 0.05). No statistical differences between Groups 2 and 3 were found in the practicum. However, there were significant differences when Groups 2 and 3 were compared with Group 1 (p < 0.05). CONCLUSIONS The authors conclude that this method promoted further improvement in knowledge for students and fostered significantly higher learning when compared with traditional teaching resources.
Correlation among auto-refractor, wavefront aberration, and subjective manual refraction
NASA Astrophysics Data System (ADS)
Li, Qi; Ren, Qiushi
2005-01-01
Three optometry methods which include auto-refractor, wavefront aberrometer and subjective manual refraction were studied and compared in measuring low order aberrations of 60 people"s 117 normal eyes. Paired t-test and linear regression were used to study these three methods" relationship when measuring myopia with astigmatism. In order to make the analysis more clear, we divided the 117 normal eyes into different groups according to their subjective manual refraction and redid the statistical analysis. Correlations among three methods show significant in sphere, cylinder and axis in all groups, with sphere"s correlation coefficients largest(R>0.98, P<0.01) and cylinder"s smallest (0.90
Bessey, Cindy; Vanderklift, Mathew A
2014-02-15
Stable isotope analysis (SIA) is a powerful tool in many fields of research that enables quantitative comparisons among studies, if similar methods have been used. The goal of this study was to determine if three different drying methods commonly used to prepare samples for SIA yielded different δ(15)N and δ(13)C values. Muscle subsamples from 10 individuals each of three teleost species were dried using three methods: (i) oven, (ii) food dehydrator, and (iii) freeze-dryer. All subsamples were analysed for δ(15)N and δ(13)C values, and nitrogen and carbon content, using a continuous flow system consisting of a Delta V Plus mass spectrometer and a Flush 1112 elemental analyser via a Conflo IV universal interface. The δ(13)C values were normalized to constant lipid content using the equations proposed by McConnaughey and McRoy. Although statistically significant, the differences in δ(15)N values between the drying methods were small (mean differences ≤0.21‰). The differences in δ(13)C values between the drying methods were not statistically significant, and normalising the δ(13)C values to constant lipid content reduced the mean differences for all treatments to ≤0.65‰. A statistically significant difference of ~2% in C content existed between tissues dried in a food dehydrator and those dried in a freeze-dryer for two fish species. There was no significant effect of fish size on the differences between methods. No substantial effect of drying method was found on the δ(15)N or δ(13)C values of teleost muscle tissue. Copyright © 2013 John Wiley & Sons, Ltd.
Levecke, Bruno; Behnke, Jerzy M.; Ajjampur, Sitara S. R.; Albonico, Marco; Ame, Shaali M.; Charlier, Johannes; Geiger, Stefan M.; Hoa, Nguyen T. V.; Kamwa Ngassam, Romuald I.; Kotze, Andrew C.; McCarthy, James S.; Montresor, Antonio; Periago, Maria V.; Roy, Sheela; Tchuem Tchuenté, Louis-Albert; Thach, D. T. C.; Vercruysse, Jozef
2011-01-01
Background The Kato-Katz thick smear (Kato-Katz) is the diagnostic method recommended for monitoring large-scale treatment programs implemented for the control of soil-transmitted helminths (STH) in public health, yet it is difficult to standardize. A promising alternative is the McMaster egg counting method (McMaster), commonly used in veterinary parasitology, but rarely so for the detection of STH in human stool. Methodology/Principal Findings The Kato-Katz and McMaster methods were compared for the detection of STH in 1,543 subjects resident in five countries across Africa, Asia and South America. The consistency of the performance of both methods in different trials, the validity of the fixed multiplication factor employed in the Kato-Katz method and the accuracy of these methods for estimating ‘true’ drug efficacies were assessed. The Kato-Katz method detected significantly more Ascaris lumbricoides infections (88.1% vs. 75.6%, p<0.001), whereas the difference in sensitivity between the two methods was non-significant for hookworm (78.3% vs. 72.4%) and Trichuris trichiura (82.6% vs. 80.3%). The sensitivity of the methods varied significantly across trials and magnitude of fecal egg counts (FEC). Quantitative comparison revealed a significant correlation (Rs >0.32) in FEC between both methods, and indicated no significant difference in FEC, except for A. lumbricoides, where the Kato-Katz resulted in significantly higher FEC (14,197 eggs per gram of stool (EPG) vs. 5,982 EPG). For the Kato-Katz, the fixed multiplication factor resulted in significantly higher FEC than the multiplication factor adjusted for mass of feces examined for A. lumbricoides (16,538 EPG vs. 15,396 EPG) and T. trichiura (1,490 EPG vs. 1,363 EPG), but not for hookworm. The McMaster provided more accurate efficacy results (absolute difference to ‘true’ drug efficacy: 1.7% vs. 4.5%). Conclusions/Significance The McMaster is an alternative method for monitoring large-scale treatment programs. It is a robust (accurate multiplication factor) and accurate (reliable efficacy results) method, which can be easily standardized. PMID:21695104
Satou, Tsukasa; Ito, Misae; Shinomiya, Yuma; Takahashi, Yoshiaki; Hara, Naoto; Niida, Takahiro
2018-04-04
To investigate differences in the stimulus accommodative convergence/accommodation (AC/A) ratio using various techniques and accommodative stimuli, and to describe a method for determining the stimulus AC/A ratio. A total of 81 subjects with a mean age of 21 years (range, 20-23 years) were enrolled. The relationship between ocular deviation and accommodation was assessed using two methods. Ocular deviation was measured by varying the accommodative requirement using spherical plus/minus lenses to create an accommodative stimulus of 10.00 diopters (D) (in 1.00 D steps). Ocular deviation was assessed using the alternate prism cover test in method 1 at distance (5 m) and near (1/3 m), and the major amblyoscope in method 2. The stimulus AC/A ratios obtained using methods 1 and 2 were calculated and defined as the stimulus AC/A ratios with low and high accommodation, respectively, using the following analysis method. The former was calculated as the difference between the convergence response to an accommodative stimulus of 3 D and 0 D, divided by 3. The latter was calculated as the difference between the convergence response to a maximum (max) accommodative stimulus with distinct vision of the subject and an accommodative stimulus of max minus 3.00 D, divided by 3. The median stimulus AC/A ratio with low accommodation (1.0 Δ/D for method 1 at distance, 2.0 Δ/D for method 1 at near, and 2.7 Δ/D for method 2) differed significantly among the measurement methods (P < 0.01). Differences in the median stimulus AC/A ratio with high accommodation (4.0 Δ/D for method 1 at distance, 3.7 Δ/D for method 1 at near, and 4.7 Δ/D for method 2) between method 1 at distance and method 2 were statistically significant (P < 0.05), while method 1 at near was not significantly different compared with other methods. Differences in the stimulus AC/A ratio value were significant according to measurement technique and accommodative stimuli. However, differences caused by measurement technique may be reduced by using a high accommodative stimulus during measurements.
Dangerous gas detection based on infrared video
NASA Astrophysics Data System (ADS)
Ding, Kang; Hong, Hanyu; Huang, Likun
2018-03-01
As the gas leak infrared imaging detection technology has significant advantages of high efficiency and remote imaging detection, in order to enhance the detail perception of observers and equivalently improve the detection limit, we propose a new type of gas leak infrared image detection method, which combines background difference methods and multi-frame interval difference method. Compared to the traditional frame methods, the multi-frame interval difference method we proposed can extract a more complete target image. By fusing the background difference image and the multi-frame interval difference image, we can accumulate the information of infrared target image of the gas leak in many aspect. The experiment demonstrate that the completeness of the gas leakage trace information is enhanced significantly, and the real-time detection effect can be achieved.
The choice of statistical methods for comparisons of dosimetric data in radiotherapy.
Chaikh, Abdulhamid; Giraud, Jean-Yves; Perrin, Emmanuel; Bresciani, Jean-Pierre; Balosso, Jacques
2014-09-18
Novel irradiation techniques are continuously introduced in radiotherapy to optimize the accuracy, the security and the clinical outcome of treatments. These changes could raise the question of discontinuity in dosimetric presentation and the subsequent need for practice adjustments in case of significant modifications. This study proposes a comprehensive approach to compare different techniques and tests whether their respective dose calculation algorithms give rise to statistically significant differences in the treatment doses for the patient. Statistical investigation principles are presented in the framework of a clinical example based on 62 fields of radiotherapy for lung cancer. The delivered doses in monitor units were calculated using three different dose calculation methods: the reference method accounts the dose without tissues density corrections using Pencil Beam Convolution (PBC) algorithm, whereas new methods calculate the dose with tissues density correction for 1D and 3D using Modified Batho (MB) method and Equivalent Tissue air ratio (ETAR) method, respectively. The normality of the data and the homogeneity of variance between groups were tested using Shapiro-Wilks and Levene test, respectively, then non-parametric statistical tests were performed. Specifically, the dose means estimated by the different calculation methods were compared using Friedman's test and Wilcoxon signed-rank test. In addition, the correlation between the doses calculated by the three methods was assessed using Spearman's rank and Kendall's rank tests. The Friedman's test showed a significant effect on the calculation method for the delivered dose of lung cancer patients (p <0.001). The density correction methods yielded to lower doses as compared to PBC by on average (-5 ± 4.4 SD) for MB and (-4.7 ± 5 SD) for ETAR. Post-hoc Wilcoxon signed-rank test of paired comparisons indicated that the delivered dose was significantly reduced using density-corrected methods as compared to the reference method. Spearman's and Kendall's rank tests indicated a positive correlation between the doses calculated with the different methods. This paper illustrates and justifies the use of statistical tests and graphical representations for dosimetric comparisons in radiotherapy. The statistical analysis shows the significance of dose differences resulting from two or more techniques in radiotherapy.
The Misgav Ladach method for cesarean section compared to the Pfannenstiel method.
Darj, E; Nordström, M L
1999-01-01
The aim of the study was to evaluate the outcome of two different methods of cesarean section (CS). The study was designed as a prospective, randomized, controlled trial. All CS were performed at the University Hospital in Uppsala, Sweden. Fifty women admitted to hospital for a first elective CS were consecutively included in the study. They were randomly allocated to two groups. One group was operated on by the Misgav Ladach method for CS and the other group by the Pfannenstiel method. All operations were performed by the same surgeon. Duration of operation, amount of bleeding, analgesics required, scar appearance and length of hospitalization. Operating time was significantly different between the two methods, with an average of 12.5 minutes with the Misgav Ladach method and 26 minutes with the Pfannenstiel method (p<0.001). The amount of blood loss differed significantly, with 448 ml and 608 ml respectively (p=0.017). Significantly less analgesic injections and tablets (p=0.004) were needed after the Misgav Ladach method. The Misgav Ladach method of CS has advantages over the Pfannenstiel method by being significantly quicker to perform, with a reduced amount of bleeding and diminished postoperative pain. The women were satisfied with the appearance of their scars. In this study no negative effects of the new operation technique were discovered.
Statistical inference methods for sparse biological time series data.
Ndukum, Juliet; Fonseca, Luís L; Santos, Helena; Voit, Eberhard O; Datta, Susmita
2011-04-25
Comparing metabolic profiles under different biological perturbations has become a powerful approach to investigating the functioning of cells. The profiles can be taken as single snapshots of a system, but more information is gained if they are measured longitudinally over time. The results are short time series consisting of relatively sparse data that cannot be analyzed effectively with standard time series techniques, such as autocorrelation and frequency domain methods. In this work, we study longitudinal time series profiles of glucose consumption in the yeast Saccharomyces cerevisiae under different temperatures and preconditioning regimens, which we obtained with methods of in vivo nuclear magnetic resonance (NMR) spectroscopy. For the statistical analysis we first fit several nonlinear mixed effect regression models to the longitudinal profiles and then used an ANOVA likelihood ratio method in order to test for significant differences between the profiles. The proposed methods are capable of distinguishing metabolic time trends resulting from different treatments and associate significance levels to these differences. Among several nonlinear mixed-effects regression models tested, a three-parameter logistic function represents the data with highest accuracy. ANOVA and likelihood ratio tests suggest that there are significant differences between the glucose consumption rate profiles for cells that had been--or had not been--preconditioned by heat during growth. Furthermore, pair-wise t-tests reveal significant differences in the longitudinal profiles for glucose consumption rates between optimal conditions and heat stress, optimal and recovery conditions, and heat stress and recovery conditions (p-values <0.0001). We have developed a nonlinear mixed effects model that is appropriate for the analysis of sparse metabolic and physiological time profiles. The model permits sound statistical inference procedures, based on ANOVA likelihood ratio tests, for testing the significance of differences between short time course data under different biological perturbations.
NASA Technical Reports Server (NTRS)
Lundberg, J. B.; Feulner, M. R.; Abusali, P. A. M.; Ho, C. S.
1991-01-01
The method of modified back differences, a technique that significantly reduces the numerical integration errors associated with crossing shadow boundaries using a fixed-mesh multistep integrator without a significant increase in computer run time, is presented. While Hubbard's integral approach can produce significant improvements to the trajectory solution, the interpolation method provides the best overall results. It is demonstrated that iterating on the point mass term correction is also important for achieving the best overall results. It is also shown that the method of modified back differences can be implemented with only a small increase in execution time.
Repeatability in Color Measurements of a Spectrophotometer using Different Positioning Devices.
Hemming, Michael; Kwon, So Ran; Qian, Fang
2015-12-01
This study aimed to evaluate the repeatability of color measurements of an intraoral spectrophotometer with the use of three different methods by two operators. A total of 60 teeth were obtained, comprising 30 human maxillary teeth [central incisors (n = 10); canines (n = 10); molars (n = 10)] and 30 artificial teeth [lateral incisors (n = 10); premolar (n = 20)]. Multiple repeated color measurements were obtained from each tooth using three measuring methods by each of the two operators. Five typodonts with alternating artificial and human teeth were made. Measurements were taken by two operators with the Vita EasyShade spectrophotometer using the custom tray (CT), custom jig (CJ) and free hand (FH) method, twice, at an interval of 2 to 7 days. Friedman test was used to detect difference among the three color measuring methods. Post hoc Wilcoxon signed-rank test with Bonferroni correction applied was used for pair-wise comparison of color measurements among the three methods. Additionally, a paired-sample t-test was used to assess a significant difference between the two duplicated measurements made on the same tooth by the same operator for each color parameter and measuring method. For operator A, mean (SD) overall color change-ΔE* (SD) perceived for FH, CT and CJ were 2.21(2.00), 2.39 (1.58) and 2.86 (1.92), respectively. There was statistically significant difference in perceived ΔE* in FH vs CJ (p = 0.0107). However, there were no significant differences between FH and CT (p = 0.2829) or between CT and CJ (p = 0.1159). For operator B mean ΔE* (SD) for FH, CT and CJ were 3.24 (3.46), 1.95 (1.19) and 2.45 (1.56), respectively. There was a significant difference between FH and CT (p = 0.0031). However, there were no statistically significant differences in ΔE* in FH vs CJ (p = 0.3696) or CT vs CJ (p = 0.0809). The repeatability of color measurements was different among the three measuring methods by operators. Overall, the CT method worked well for both operators. The use of a custom tray with apertures can improve the repeatability of color measurements of an intraoral spectrophotometer.
Spiric, Aurelija; Trbovic, Dejana; Vranic, Danijela; Djinovic, Jasna; Petronijevic, Radivoj; Matekalo-Sverak, Vesna
2010-07-05
Studies performed on lipid extraction from animal and fish tissues do not provide information on its influence on fatty acid composition of the extracted lipids as well as on cholesterol content. Data presented in this paper indicate the impact of extraction procedures on fatty acid profile of fish lipids extracted by the modified Soxhlet and ASE (accelerated solvent extraction) procedure. Cholesterol was also determined by direct saponification method, too. Student's paired t-test used for comparison of the total fat content in carp fish population obtained by two extraction methods shows that differences between values of the total fat content determined by ASE and modified Soxhlet method are not statistically significant. Values obtained by three different methods (direct saponification, ASE and modified Soxhlet method), used for determination of cholesterol content in carp, were compared by one-way analysis of variance (ANOVA). The obtained results show that modified Soxhlet method gives results which differ significantly from the results obtained by direct saponification and ASE method. However the results obtained by direct saponification and ASE method do not differ significantly from each other. The highest quantities for cholesterol (37.65 to 65.44 mg/100 g) in the analyzed fish muscle were obtained by applying direct saponification method, as less destructive one, followed by ASE (34.16 to 52.60 mg/100 g) and modified Soxhlet extraction method (10.73 to 30.83 mg/100 g). Modified Soxhlet method for extraction of fish lipids gives higher values for n-6 fatty acids than ASE method (t(paired)=3.22 t(c)=2.36), while there is no statistically significant difference in the n-3 content levels between the methods (t(paired)=1.31). The UNSFA/SFA ratio obtained by using modified Soxhlet method is also higher than the ratio obtained using ASE method (t(paired)=4.88 t(c)=2.36). Results of Principal Component Analysis (PCA) showed that the highest positive impact to the second principal component (PC2) is recorded by C18:3 n-3, and C20:3 n-6, being present in a higher amount in the samples treated by the modified Soxhlet extraction, while C22:5 n-3, C20:3 n-3, C22:1 and C20:4, C16 and C18 negatively influence the score values of the PC2, showing significantly increased level in the samples treated by ASE method. Hotelling's paired T-square test used on the first three principal components for confirmation of differences in individual fatty acid content obtained by ASE and Soxhlet method in carp muscle showed statistically significant difference between these two data sets (T(2)=161.308, p<0.001). Copyright 2010 Elsevier B.V. All rights reserved.
The Effects of Process Oriented Guided Inquiry Learning on Secondary Student ACT Science Scores
NASA Astrophysics Data System (ADS)
Judd, William Lindsey
The purpose of this study was to examine any significant difference on secondary school chemistry students' ACT Science Test scores between students taught by the Process Oriented Guided Inquiry Learning (POGIL) method versus students taught by traditional, teacher-centered pedagogy. This study also examined any difference between students taught by the POGIL method versus students taught by traditional, teacher-centered pedagogy in regard to the three different types of questions on the ACT Science Test: data representation, research summaries, and conflicting viewpoints. The sample consisted of sophomore-level students at two private, suburban Christian schools. A pretest-posttest design was used to compare the mean difference in scores from ACT issued sample test booklets before and after each group had received instruction via the POGIL method or more traditional methods. This study found that there was no significant difference in the mean difference of test scores between the two groups. This study also found that there was not a significant difference in the mean difference of scores in regard to the three different types of questions on the ACT Science Test. Further implications of this study are discussed.
Stress responses to comparative handling procedures in sheep.
Yardimci, M; Sahin, E H; Cetingul, I S; Bayram, I; Aslan, R; Sengor, E
2013-01-01
The objective of this study was to compare some husbandry procedures on the base of physiological stress parameters and evaluate the welfare status in sheep. Forty ewes were used as the study material. Measurements were taken during several routine husbandry procedures such as milking, shearing, weighing, loading and hoof care. Data regarding time spent for each application, as well as heart and respiratory rates were recorded during the applications. Blood samples were taken 15 min before and after each application and malondialdehyde (MDA), glutathione-peroxidase (GSH-Px), cortisol T(3) and T(4) parameters were measured. In addition, changes in the same parameters between pre- and post-application periods were evaluated. According to the results, machine milking caused less stress than hand milking. No significant difference was seen between shearing methods for hand shearer or clipper; however, both applications caused stress in animals. The results for weighing methods of animals demonstrated significant differences in cortisol, T(3) and T(4) values in favor of traditional method. Cortisol, T(3) and T(4) levels were significantly higher in manual loading compared with loading by ramp. Regarding hoof care, all the examined parameters differed in favor of modern method. On the other hand, significant differences were determined between the stress parameters regarding pre- and post-applications. All values differed for hand milking while no significant difference was observed in MDA and T(3) values in machine milking group. Parameters in weighing groups changed significantly. For loading process, GSH, cortisol, T(3) and T(4) values differed in both treatment groups. With regard to hoof care, parameters except T(4) in laying group differed significantly. An increase occurred in minute-based measurements of heart and respiratory rates parallel to physiological data. The number of the respiratory rates during the applications differed except for the shearing process. All the parameters displayed significant differences between groups in terms of heart rates. Time spent for each application also differed between groups. Time saved for milking, shearing, weighing, loading and hoof care was 3.23 min, 4.37 min, 1.71 min, 7.85 s and 1.55 min, respectively. These results appear to provide a tangible advantage of using new husbandry methods to the breeders. It was concluded that using new methods in sheep husbandry procedures provided advantages in terms of saving time and reducing labor, as well as improved conditions for welfare of animals. In addition, it facilitated the routine works and flock husbandry.
Downscaling Global Emissions and Its Implications Derived from Climate Model Experiments
Abe, Manabu; Kinoshita, Tsuguki; Hasegawa, Tomoko; Kawase, Hiroaki; Kushida, Kazuhide; Masui, Toshihiko; Oka, Kazutaka; Shiogama, Hideo; Takahashi, Kiyoshi; Tatebe, Hiroaki; Yoshikawa, Minoru
2017-01-01
In climate change research, future scenarios of greenhouse gas and air pollutant emissions generated by integrated assessment models (IAMs) are used in climate models (CMs) and earth system models to analyze future interactions and feedback between human activities and climate. However, the spatial resolutions of IAMs and CMs differ. IAMs usually disaggregate the world into 10–30 aggregated regions, whereas CMs require a grid-based spatial resolution. Therefore, downscaling emissions data from IAMs into a finer scale is necessary to input the emissions into CMs. In this study, we examined whether differences in downscaling methods significantly affect climate variables such as temperature and precipitation. We tested two downscaling methods using the same regionally aggregated sulfur emissions scenario obtained from the Asian-Pacific Integrated Model/Computable General Equilibrium (AIM/CGE) model. The downscaled emissions were fed into the Model for Interdisciplinary Research on Climate (MIROC). One of the methods assumed a strong convergence of national emissions intensity (e.g., emissions per gross domestic product), while the other was based on inertia (i.e., the base-year remained unchanged). The emissions intensities in the downscaled spatial emissions generated from the two methods markedly differed, whereas the emissions densities (emissions per area) were similar. We investigated whether the climate change projections of temperature and precipitation would significantly differ between the two methods by applying a field significance test, and found little evidence of a significant difference between the two methods. Moreover, there was no clear evidence of a difference between the climate simulations based on these two downscaling methods. PMID:28076446
Comparison of macro-gravimetric and micro-colorimetric lipid determination methods.
Inouye, Laura S; Lotufo, Guiherme R
2006-10-15
In order to validate a method for lipid analysis of small tissue samples, the standard macro-gravimetric method of Bligh-Dyer (1959) [E.G. Bligh, W.J. Dyer, Can. J. Biochem. Physiol. 37 (1959) 911] and a modification of the micro-colorimetric assay developed by Van Handel (1985) [E. Van Handel, J. Am. Mosq. Control Assoc. 1 (1985) 302] were compared. No significant differences were observed for wet tissues of two species of fish. However, limited analysis of wet tissue of the amphipod, Leptocheirusplumulosus, indicated that the Bligh-Dyer gravimetric method generated higher lipid values, most likely due to the inclusion of non-lipid materials. Additionally, significant differences between the methods were observed with dry tissues, with the micro-colorimetric method consistently reporting calculated lipid values greater than as reported by the gravimetric method. This was most likely due to poor extraction of dry tissue in the standard Bligh-Dyer method, as no significant differences were found when analyzing a single composite extract. The data presented supports the conclusion that the micro-colorimetric method described in this paper is accurate, rapid, and minimizes time and solvent use.
Nunes, Sheila Elke Araujo; Minamisava, Ruth; Vieira, Maria Aparecida da Silva; Itria, Alexander; Pessoa, Vicente Porfirio; de Andrade, Ana Lúcia Sampaio Sgambatti; Toscano, Cristiana Maria
2017-01-01
ABSTRACT Objective To determine and compare hospitalization costs of bacterial community-acquired pneumonia cases via different costing methods under the Brazilian Public Unified Health System perspective. Methods Cost-of-illness study based on primary data collected from a sample of 59 children aged between 28 days and 35 months and hospitalized due to bacterial pneumonia. Direct medical and non-medical costs were considered and three costing methods employed: micro-costing based on medical record review, micro-costing based on therapeutic guidelines and gross-costing based on the Brazilian Public Unified Health System reimbursement rates. Costs estimates obtained via different methods were compared using the Friedman test. Results Cost estimates of inpatient cases of severe pneumonia amounted to R$ 780,70/$Int. 858.7 (medical record review), R$ 641,90/$Int. 706.90 (therapeutic guidelines) and R$ 594,80/$Int. 654.28 (Brazilian Public Unified Health System reimbursement rates). Costs estimated via micro-costing (medical record review or therapeutic guidelines) did not differ significantly (p=0.405), while estimates based on reimbursement rates were significantly lower compared to estimates based on therapeutic guidelines (p<0.001) or record review (p=0.006). Conclusion Brazilian Public Unified Health System costs estimated via different costing methods differ significantly, with gross-costing yielding lower cost estimates. Given costs estimated by different micro-costing methods are similar and costing methods based on therapeutic guidelines are easier to apply and less expensive, this method may be a valuable alternative for estimation of hospitalization costs of bacterial community-acquired pneumonia in children. PMID:28767921
Computationally efficient finite-difference modal method for the solution of Maxwell's equations.
Semenikhin, Igor; Zanuccoli, Mauro
2013-12-01
In this work, a new implementation of the finite-difference (FD) modal method (FDMM) based on an iterative approach to calculate the eigenvalues and corresponding eigenfunctions of the Helmholtz equation is presented. Two relevant enhancements that significantly increase the speed and accuracy of the method are introduced. First of all, the solution of the complete eigenvalue problem is avoided in favor of finding only the meaningful part of eigenmodes by using iterative methods. Second, a multigrid algorithm and Richardson extrapolation are implemented. Simultaneous use of these techniques leads to an enhancement in terms of accuracy, which allows a simple method such as the FDMM with a typical three-point difference scheme to be significantly competitive with an analytical modal method.
AlBarakati, SF; Kula, KS; Ghoneima, AA
2012-01-01
Objective The aim of this study was to assess the reliability and reproducibility of angular and linear measurements of conventional and digital cephalometric methods. Methods A total of 13 landmarks and 16 skeletal and dental parameters were defined and measured on pre-treatment cephalometric radiographs of 30 patients. The conventional and digital tracings and measurements were performed twice by the same examiner with a 6 week interval between measurements. The reliability within the method was determined using Pearson's correlation coefficient (r2). The reproducibility between methods was calculated by paired t-test. The level of statistical significance was set at p < 0.05. Results All measurements for each method were above 0.90 r2 (strong correlation) except maxillary length, which had a correlation of 0.82 for conventional tracing. Significant differences between the two methods were observed in most angular and linear measurements except for ANB angle (p = 0.5), angle of convexity (p = 0.09), anterior cranial base (p = 0.3) and the lower anterior facial height (p = 0.6). Conclusion In general, both methods of conventional and digital cephalometric analysis are highly reliable. Although the reproducibility of the two methods showed some statistically significant differences, most differences were not clinically significant. PMID:22184624
Oliveira, Fernanda Granja da Silva; de Lima-Saraiva, Sarah Raquel Gomes; Oliveira, Ana Paula; Rabêlo, Suzana Vieira; Rolim, Larissa Araújo; Almeida, Jackson Roberto Guedes da Silva
2016-01-01
Background: Popularly known as “jatobá,” Hymenaea martiana Hayne is a medicinal plant widely used in the Brazilian Northeast for the treatment of various diseases. Objective: The aim of this study was to evaluate the influence of different extractive methods in the production of phenolic compounds from different parts of H. martiana. Materials and Methods: The leaves, bark, fruits, and seeds were dried, pulverized, and submitted to maceration, ultrasound, and percolation extractive methods, which were evaluated for yield, visual aspects, qualitative phytochemical screening, phenolic compound content, and total flavonoids. Results: The highest results of yield were obtained from the maceration of the leaves, which may be related to the contact time between the plant drug and solvent. The visual aspects of the extracts presented some differences between the extractive methods. The phytochemical screening showed consistent data with other studies of the genus. Both the vegetal part as the different extractive methods influenced significantly the levels of phenolic compounds, and the highest content was found in the maceration of the barks, even more than the content found previously. No differences between the levels of total flavonoids were significant. The highest concentration of total flavonoids was found in the ultrasound of the barks, followed by maceration on this drug. According to the results, the barks of H. martiana presented the highest total flavonoid contents. Conclusion: The results demonstrate that both the vegetable and the different extractive methods influenced significantly various parameters obtained in the various extracts, demonstrating the importance of systematic comparative studies for the development of pharmaceuticals and cosmetics. SUMMARY The phytochemical screening showed consistent data with other studies of the genus HymenaeaBoth the vegetable part and the different extractive methods influenced significantly various parameters obtained in the various extracts, including the levels of phenolic compoundsThe barks of H. martiana presented the highest total phenolic and flavonoid contents. PMID:27695267
NASA Astrophysics Data System (ADS)
Wang, Dong
2016-03-01
Gears are the most commonly used components in mechanical transmission systems. Their failures may cause transmission system breakdown and result in economic loss. Identification of different gear crack levels is important to prevent any unexpected gear failure because gear cracks lead to gear tooth breakage. Signal processing based methods mainly require expertize to explain gear fault signatures which is usually not easy to be achieved by ordinary users. In order to automatically identify different gear crack levels, intelligent gear crack identification methods should be developed. The previous case studies experimentally proved that K-nearest neighbors based methods exhibit high prediction accuracies for identification of 3 different gear crack levels under different motor speeds and loads. In this short communication, to further enhance prediction accuracies of existing K-nearest neighbors based methods and extend identification of 3 different gear crack levels to identification of 5 different gear crack levels, redundant statistical features are constructed by using Daubechies 44 (db44) binary wavelet packet transform at different wavelet decomposition levels, prior to the use of a K-nearest neighbors method. The dimensionality of redundant statistical features is 620, which provides richer gear fault signatures. Since many of these statistical features are redundant and highly correlated with each other, dimensionality reduction of redundant statistical features is conducted to obtain new significant statistical features. At last, the K-nearest neighbors method is used to identify 5 different gear crack levels under different motor speeds and loads. A case study including 3 experiments is investigated to demonstrate that the developed method provides higher prediction accuracies than the existing K-nearest neighbors based methods for recognizing different gear crack levels under different motor speeds and loads. Based on the new significant statistical features, some other popular statistical models including linear discriminant analysis, quadratic discriminant analysis, classification and regression tree and naive Bayes classifier, are compared with the developed method. The results show that the developed method has the highest prediction accuracies among these statistical models. Additionally, selection of the number of new significant features and parameter selection of K-nearest neighbors are thoroughly investigated.
Smolek, Michael K.
2011-01-01
Purpose The significance of ocular or corneal aberrations may be subject to misinterpretation whenever eyes with different pupil sizes or the application of different Zernike expansion orders are compared. A method is shown that uses simple mathematical interpolation techniques based on normal data to rapidly determine the clinical significance of aberrations, without concern for pupil and expansion order. Methods Corneal topography (Tomey, Inc.; Nagoya, Japan) from 30 normal corneas was collected and the corneal wavefront error analyzed by Zernike polynomial decomposition into specific aberration types for pupil diameters of 3, 5, 7, and 10 mm and Zernike expansion orders of 6, 8, 10 and 12. Using this 4×4 matrix of pupil sizes and fitting orders, best-fitting 3-dimensional functions were determined for the mean and standard deviation of the RMS error for specific aberrations. The functions were encoded into software to determine the significance of data acquired from non-normal cases. Results The best-fitting functions for 6 types of aberrations were determined: defocus, astigmatism, prism, coma, spherical aberration, and all higher-order aberrations. A clinical screening method of color-coding the significance of aberrations in normal, postoperative LASIK, and keratoconus cases having different pupil sizes and different expansion orders is demonstrated. Conclusions A method to calibrate wavefront aberrometry devices by using a standard sample of normal cases was devised. This method could be potentially useful in clinical studies involving patients with uncontrolled pupil sizes or in studies that compare data from aberrometers that use different Zernike fitting-order algorithms. PMID:22157570
NASA Astrophysics Data System (ADS)
Beam, Margery Elizabeth
The combination of increasing enrollment and the importance of providing transfer students a solid foundation in science calls for science faculty to evaluate teaching methods in rural community colleges. The purpose of this study was to examine and compare the effectiveness of two teaching methods, inquiry teaching methods and didactic teaching methods, applied in a rural community college earth science course. Two groups of students were taught the same content via inquiry and didactic teaching methods. Analysis of quantitative data included a non-parametric ranking statistical testing method in which the difference between the rankings and the median of the post-test scores was analyzed for significance. Results indicated there was not a significant statistical difference between the teaching methods for the group of students participating in the research. The practical and educational significance of this study provides valuable perspectives on teaching methods and student learning styles in rural community colleges.
Oyugi, Boniface; Kioko, Urbanus; Kaboro, Stephen Mbugua; Gikonyo, Shadrack; Okumu, Clarice; Ogola-Munene, Sarah; Kalsi, Shaminder; Thiani, Simon; Korir, Julius; Odundo, Paul; Baltazaar, Billy; Ranji, Moses; Muraguri, Nicholas; Nzioka, Charles
2017-03-27
The study seeks to evaluate the difference in access of long-term family planning (LTFP) methods among the output based approach (OBA) and non-OBA clients within the OBA facility. The study utilises a quasi experimental design. A two tailed unpaired t-test with unequal variance is used to test for the significance variation in the mean access. The difference in difference (DiD) estimates of program effect on long term family planning methods is done to estimate the causal effect by exploiting the group level difference on two or more dimensions. The study also uses a linear regression model to evaluate the predictors of choice of long-term family planning methods. Data was analysed using SPSS version 17. All the methods (Bilateral tubal ligation-BTL, Vasectomy, intrauterine contraceptive device -IUCD, Implants, and Total or combined long-term family planning methods -LTFP) showed a statistical significant difference in the mean utilization between OBA versus non-OBA clients. The difference in difference estimates reveal that the difference in access between OBA and non OBA clients can significantly be attributed to the implementation of the OBA program for intrauterine contraceptive device (p = 0.002), Implants (p = 0.004), and total or combined long-term family planning methods (p = 0.001). The county of residence is a significant determinant of access to all long-term family planning methods except vasectomy and the year of registration is a significant determinant of access especially for implants and total or combined long-term family planning methods. The management level and facility type does not play a role in determining the type of long-term family planning method preferred; however, non-governmental organisations (NGOs) as management level influences the choice of all methods (Bilateral tubal ligation, intrauterine contraceptive device, Implants, and combined methods) except vasectomy. The adjusted R 2 value, representing the percentage of the variance explained by various models, is larger than 18% for implants and total or combined long-term family planning. The study showed that the voucher services in Kenya has been effective in providing long-term family planning services and improving access of care provided to women of reproductive age. Therefore, voucher scheme can be used as a tool for bridging the gap of unmet needs of family planning in Kenya and could potentially be more effective if rolled out to other counties.
Marginal and Internal Adaptation of Zirconia Crowns: A Comparative Study of Assessment Methods.
Cunali, Rafael Schlögel; Saab, Rafaella Caramori; Correr, Gisele Maria; Cunha, Leonardo Fernandes da; Ornaghi, Bárbara Pick; Ritter, André V; Gonzaga, Carla Castiglia
2017-01-01
Marginal and internal adaptation is critical for the success of indirect restorations. New imaging systems make it possible to evaluate these parameters with precision and non-destructively. This study evaluated the marginal and internal adaptation of zirconia copings fabricated with two different systems using both silicone replica and microcomputed tomography (micro-CT) assessment methods. A metal master model, representing a preparation for an all-ceramic full crown, was digitally scanned and polycrystalline zirconia copings were fabricated with either Ceramill Zi (Amann-Girrbach) or inCoris Zi (Dentslpy-Sirona), n=10. For each coping, marginal and internal gaps were evaluated by silicone replica and micro-CT assessment methods. Four assessment points of each replica cross-section and micro-CT image were evaluated using imaging software: marginal gap (MG), axial wall (AW), axio-occlusal angle (AO) and mid-occlusal wall (MO). Data were statistically analyzed by factorial ANOVA and Tukey test (a=0.05). There was no statistically significant difference between the methods for MG and AW. For AO, there were significant differences between methods for Amann copings, while for Dentsply-Sirona copings similar values were observed. For MO, both methods presented statistically significant differences. A positive correlation was observed determined by the two assessment methods for MG values. In conclusion, the assessment method influenced the evaluation of marginal and internal adaptation of zirconia copings. Micro-CT showed lower marginal and internal gap values when compared to the silicone replica technique, although the difference was not always statistically significant. Marginal gap and axial wall assessment points showed the lower gap values, regardless of ceramic system and assessment method used.
Khajouei, Reza; Hajesmaeel Gohari, Sadrieh; Mirzaee, Moghaddameh
2018-04-01
In addition to following the usual Heuristic Evaluation (HE) method, the usability of health information systems can also be evaluated using a checklist. The objective of this study is to compare the performance of these two methods in identifying usability problems of health information systems. Eight evaluators independently evaluated different parts of a Medical Records Information System using two methods of HE (usual and with a checklist). The two methods were compared in terms of the number of problems identified, problem type, and the severity of identified problems. In all, 192 usability problems were identified by two methods in the Medical Records Information System. This was significantly higher than the number of usability problems identified by the checklist and usual method (148 and 92, respectively) (p < 0.0001). After removing the duplicates, the difference between the number of unique usability problems identified by the checklist method (n = 100) and usual method (n = 44) was significant (p < 0.0001). Differences between the mean severity of the real usability problems (1.83) and those identified by only one of the methods (usual = 2.05, checklist = 1.74) were significant (p = 0.001). This study revealed the potential of the two HE methods for identifying usability problems of health information systems. The results demonstrated that the checklist method had significantly better performance in terms of the number of identified usability problems; however, the performance of the usual method for identifying problems of higher severity was significantly better. Although the checklist method can be more efficient for less experienced evaluators, wherever usability is critical, the checklist should be used with caution in usability evaluations. Copyright © 2018 Elsevier Inc. All rights reserved.
Ren, Yan; Qiu, Yi; Wan, De-Guang; Lu, Xian-Ming; Guo, Jin-Lin
2013-05-01
To analyze the content and type of soluble proteins in Cordyceps sinensis from different producing areas and processed with different methods with bradford method and 2-DE technology, in order to discover significant differences in soluble proteins in C. sinensis processed with different methods and from different producing areas. The preliminary study indicated that the content and diversity of soluble proteins were related to producing areas and processing methods to some extent.
Effect of Dietary Fiber Enrichment and Different Cooking Methods on Quality of Chicken Nuggets.
Pathera, Ashok K; Riar, C S; Yadav, Sanjay; Sharma, D P
2017-01-01
The effect of dietary fiber enrichment (wheat bran) and cooking methods (oven, steam and microwave) on functional and physico-chemical properties of raw nuggets formulation as well as nutritional, color and textural properties of chicken nuggets were analyzed in this study. Among different cooking methods used for nuggets preparation, steam cooked nuggets had significantly ( p <0.05) higher water holding capacity (56.65%), cooking yield (97.16%) and total dietary fiber content (4.32%) in comparison to oven and microwave cooked nuggets. The effect of cooking methods and wheat bran incorporation was also noticed on textural properties of the nuggets. Hardness, firmness and toughness values of oven and steam cooked nuggets were significantly ( p <0.05) higher than microwave cooked nuggets. Among nuggets prepared by different cooking methods, cohesiveness of microwave cooked nuggets was found to be significantly ( p <0.05) highest, whereas, oven cooked nuggets had significantly ( p <0.05) highest gumminess and chewiness values. Steam cooked nuggets were found to be better among all nuggets due to their higher cooking yield and dietary fiber content.
Effect of Dietary Fiber Enrichment and Different Cooking Methods on Quality of Chicken Nuggets
Yadav, Sanjay; Sharma, D. P.
2017-01-01
The effect of dietary fiber enrichment (wheat bran) and cooking methods (oven, steam and microwave) on functional and physico-chemical properties of raw nuggets formulation as well as nutritional, color and textural properties of chicken nuggets were analyzed in this study. Among different cooking methods used for nuggets preparation, steam cooked nuggets had significantly (p<0.05) higher water holding capacity (56.65%), cooking yield (97.16%) and total dietary fiber content (4.32%) in comparison to oven and microwave cooked nuggets. The effect of cooking methods and wheat bran incorporation was also noticed on textural properties of the nuggets. Hardness, firmness and toughness values of oven and steam cooked nuggets were significantly (p<0.05) higher than microwave cooked nuggets. Among nuggets prepared by different cooking methods, cohesiveness of microwave cooked nuggets was found to be significantly (p<0.05) highest, whereas, oven cooked nuggets had significantly (p<0.05) highest gumminess and chewiness values. Steam cooked nuggets were found to be better among all nuggets due to their higher cooking yield and dietary fiber content. PMID:28747827
Marshall, Leisa L; Nykamp, Diane L; Momary, Kathryn M
2014-12-15
To compare the impact of 2 different teaching and learning methods on student mastery of learning objectives in a pharmacotherapy module in the large classroom setting. Two teaching and learning methods were implemented and compared in a required pharmacotherapy module for 2 years. The first year, multiple interactive mini-cases with inclass individual assessment and an abbreviated lecture were used to teach osteoarthritis; a traditional lecture with 1 inclass case discussion was used to teach gout. In the second year, the same topics were used but the methods were flipped. Student performance on pre/post individual readiness assessment tests (iRATs), case questions, and subsequent examinations were compared each year by the teaching and learning method and then between years by topic for each method. Students also voluntarily completed a 20-item evaluation of the teaching and learning methods. Postpresentation iRATs were significantly higher than prepresentation iRATs for each topic each year with the interactive mini-cases; there was no significant difference in iRATs before and after traditional lecture. For osteoarthritis, postpresentation iRATs after interactive mini-cases in year 1 were significantly higher than postpresentation iRATs after traditional lecture in year 2; the difference in iRATs for gout per learning method was not significant. The difference between examination performance for osteoarthritis and gout was not significant when the teaching and learning methods were compared. On the student evaluations, 2 items were significant both years when answers were compared by teaching and learning method. Each year, students ranked their class participation higher with interactive cases than with traditional lecture, but both years they reported enjoying the traditional lecture format more. Multiple interactive mini-cases with an abbreviated lecture improved immediate mastery of learning objectives compared to a traditional lecture format, regardless of therapeutic topic, but did not improve student performance on subsequent examinations.
Gill, Christina; van de Wijgert, Janneke H H M; Blow, Frances; Darby, Alistair C
2016-01-01
Recent studies on the vaginal microbiota have employed molecular techniques such as 16S rRNA gene sequencing to describe the bacterial community as a whole. These techniques require the lysis of bacterial cells to release DNA before purification and PCR amplification of the 16S rRNA gene. Currently, methods for the lysis of bacterial cells are not standardised and there is potential for introducing bias into the results if some bacterial species are lysed less efficiently than others. This study aimed to compare the results of vaginal microbiota profiling using four different pretreatment methods for the lysis of bacterial samples (30 min of lysis with lysozyme, 16 hours of lysis with lysozyme, 60 min of lysis with a mixture of lysozyme, mutanolysin and lysostaphin and 30 min of lysis with lysozyme followed by bead beating) prior to chemical and enzyme-based DNA extraction with a commercial kit. After extraction, DNA yield did not significantly differ between methods with the exception of lysis with lysozyme combined with bead beating which produced significantly lower yields when compared to lysis with the enzyme cocktail or 30 min lysis with lysozyme only. However, this did not result in a statistically significant difference in the observed alpha diversity of samples. The beta diversity (Bray-Curtis dissimilarity) between different lysis methods was statistically significantly different, but this difference was small compared to differences between samples, and did not affect the grouping of samples with similar vaginal bacterial community structure by hierarchical clustering. An understanding of how laboratory methods affect the results of microbiota studies is vital in order to accurately interpret the results and make valid comparisons between studies. Our results indicate that the choice of lysis method does not prevent the detection of effects relating to the type of vaginal bacterial community one of the main outcome measures of epidemiological studies. However, we recommend that the same method is used on all samples within a particular study.
Zhuang, H; Savage, E M
2008-10-01
Quality assessment results of cooked meat can be significantly affected by sample preparation with different cooking techniques. A combi oven is a relatively new cooking technique in the U.S. market. However, there was a lack of published data about its effect on quality measurements of chicken meat. Broiler breast fillets deboned at 24-h postmortem were cooked with one of the 3 methods to the core temperature of 80 degrees C. Cooking methods were evaluated based on cooking operation requirements, sensory profiles, Warner-Bratzler (WB) shear and cooking loss. Our results show that the average cooking time for the combi oven was 17 min compared with 31 min for the commercial oven method and 16 min for the hot water method. The combi oven did not result in a significant difference in the WB shear force values, although the cooking loss of the combi oven samples was significantly lower than the commercial oven and hot water samples. Sensory profiles of the combi oven samples did not significantly differ from those of the commercial oven and hot water samples. These results demonstrate that combi oven cooking did not significantly affect sensory profiles and WB shear force measurements of chicken breast muscle compared to the other 2 cooking methods. The combi oven method appears to be an acceptable alternative for preparing chicken breast fillets in a quality assessment.
NASA Astrophysics Data System (ADS)
Cheema, Tabinda Shahid
This study of laboratory based instruction at higher secondary school level was an attempt to gain some insight into the effectiveness of three laboratory instruction methods: cooperative group instruction method, individualised instruction method and lecture demonstration method on biology achievement and retention. A Randomised subjects, Pre-test Post-test Comparative Methods Design was applied. Three groups of students from a year 11 class in Pakistan conducted experiments using the different laboratory instruction methods. Pre-tests, achievement tests after the experiments and retention tests one month later were administered. Results showed no significant difference between the groups on total achievement and retention, nor was there any significant difference on knowledge and comprehension test scores or skills performance. Future research investigating a similar problem is suggested.
Comparison of Histograms for Use in Cloud Observation and Modeling
NASA Technical Reports Server (NTRS)
Green, Lisa; Xu, Kuan-Man
2005-01-01
Cloud observation and cloud modeling data can be presented in histograms for each characteristic to be measured. Combining information from single-cloud histograms yields a summary histogram. Summary histograms can be compared to each other to reach conclusions about the behavior of an ensemble of clouds in different places at different times or about the accuracy of a particular cloud model. As in any scientific comparison, it is necessary to decide whether any apparent differences are statistically significant. The usual methods of deciding statistical significance when comparing histograms do not apply in this case because they assume independent data. Thus, a new method is necessary. The proposed method uses the Euclidean distance metric and bootstrapping to calculate the significance level.
NASA Astrophysics Data System (ADS)
Sugiyanto, Pribadi, Supriyanto, Bambang
2017-09-01
The purpose of this study was to investigate the effectiveness of Creative & Productive instructional method compared with conventional method. This research was a quasi-experimental study involving all Civil Engineering students at Universitas Negeri Malang who were taking a course of Steel Structure. The students were randomly assigned to two different treatment groups, 30 students in experimental group and 37 students in the control group. It was assumed that these groups were equal in all relevant aspects; they differed only in the treatment administered. We used the t-test to test the hypothesis. The results of this research suggest that: (l) the use of Creative & Productive instructional method can significantly improve students' learning achievement, (2) the use of Creative & Productive instructional method can significantly improve students' retention, (3) students' motivation has a significant effect on their learning achievement, and (4) students' motivation has a significant effect on their retention.
Comparison of histomorphometrical data obtained with two different image analysis methods.
Ballerini, Lucia; Franke-Stenport, Victoria; Borgefors, Gunilla; Johansson, Carina B
2007-08-01
A common way to determine tissue acceptance of biomaterials is to perform histomorphometrical analysis on histologically stained sections from retrieved samples with surrounding tissue, using various methods. The "time and money consuming" methods and techniques used are often "in house standards". We address light microscopic investigations of bone tissue reactions on un-decalcified cut and ground sections of threaded implants. In order to screen sections and generate results faster, the aim of this pilot project was to compare results generated with the in-house standard visual image analysis tool (i.e., quantifications and judgements done by the naked eye) with a custom made automatic image analysis program. The histomorphometrical bone area measurements revealed no significant differences between the methods but the results of the bony contacts varied significantly. The raw results were in relative agreement, i.e., the values from the two methods were proportional to each other: low bony contact values in the visual method corresponded to low values with the automatic method. With similar resolution images and further improvements of the automatic method this difference should become insignificant. A great advantage using the new automatic image analysis method is that it is time saving--analysis time can be significantly reduced.
Shabzendedar, Mahbobeh; Moosavi, Horieh; Talbi, Maryam; Sharifi, Marjan
2011-11-01
The goal of the study was to evaluate the effect of caries removal by three various methods on the permeability of class II composite resin restorations in primary molar teeth. Forty-five recently extracted primary molars were randomly assigned to three groups for three different methods of caries removal; group 1-mechanical, group 2-caries detector dye, and group 3-Carisolv (n = 15). After that, class II cavities in all groups were restored with the adhesive (Opti Bond Solo Plus) that was applied according to the manufacturer's instruction and a posterior composite (Herculite XRV), which was used incrementally. After 24 hours the samples were thermocycled in water for 500 cycles between 5 and 55°C with a dwell time of 30 sec. Permeability was assessed by the fluid filtration method. The data were analyzed using the ANOVA test while study groups were compared with Tukey test for statistically significant differences at a 5% significance level. The evaluation of tested groups indicated that the highest (0.80) and least (0.37) mean of permeability was observed in group 2 and 3 respectively. Significant difference was revealed among the tested groups (p = 0.045). The comparison of Carisolv and caries detector dye groups indicated a statistically significant difference (p = 0.037). There was not any significant difference between Carisolv or caries dye in the conventional group. Using the chemomechanical and staining methods for caries removal had no more detrimental effect on permeability than the conventional technique. However, caries detection dye for caries removal could be more harmful than chemomechanical method. None of the current caries-excavation techniques could eliminate permeability in class II composite resin restorations. Furthermore, staining methods do not have an adverse effect on sealing ability in comparison to the conventional technique.
Effect of thawing methods on frozen semen quality of yak (Poephagus grunniens L.) bulls
Borah, Binod Kumar Dutta; Deka, Bharat Chandra; Biswas, Ranjan Kumar; Chakravarty, Prithiviraj; Deori, Sourabh; Sinha, Sudip; Ahmed, Kutubuddin
2015-01-01
Aim: To evaluate different thawing temperatures and duration on the post-thaw semen quality of Indian yaks bulls. Materials and Methods: Semen ejaculates from four different yak bulls were collected using artificial vagina method and extended with tris extender containing 6.4% glycerol at 35°C, cooled gradually from 35°C to 5°C at 1°C/3 min and equilibrated at 4-5°C for 4 h and frozen in French mini straws using a programmable bio-freezer and finally stored in liquid nitrogen. Thawing of frozen semen straws was carried out using three methods i.e., 35°C for 60 s (thawing method I), 37°C for 30 s (thawing method II) and 75°C for 9 s (thawing method III). The post-thaw semen quality parameters assessed were sperm motility, percent live sperm, hypo-osmotic swelling test (HOST)-reacted sperm, acrosomal changes, and alanine aminotransferase (ALT) and aspartate aminotransferase (AST) activities in the extracellular media. Results: The percent sperm motility, total incidence of acrosomal changes, and extracellular release of AST varied significantly (p<0.01) between thawing methods but live sperm and HOST-reacted sperm did not vary significantly between thawing methods. The percent sperm motility of frozen yak semen for thawing method III was significantly (p<0.05) higher than that for thawing methods I and II, the difference between thawing methods I and II being non-significant. The critical difference test revealed that the total incidence of acrosomal changes and extracellular release of AST were significantly (p<0.05) lower when thawing was done using methods I and II than in method III. Conclusion: On the basis of the present experiment, we can conclude that barring the post-thaw sperm motility, thawing of frozen yak semen in water either at 35°C for 60 s or 37°C for 30 s gives better post-thaw semen quality than at 75°C for 09 s. PMID:27047161
Frank, Lawrence D; Fox, Eric H; Ulmer, Jared M; Chapman, James E; Kershaw, Suzanne E; Sallis, James F; Conway, Terry L; Cerin, Ester; Cain, Kelli L; Adams, Marc A; Smith, Graham R; Hinckson, Erica; Mavoa, Suzanne; Christiansen, Lars B; Hino, Adriano Akira F; Lopes, Adalberto A S; Schipperijn, Jasper
2017-01-23
Advancements in geographic information systems over the past two decades have increased the specificity by which an individual's neighborhood environment may be spatially defined for physical activity and health research. This study investigated how different types of street network buffering methods compared in measuring a set of commonly used built environment measures (BEMs) and tested their performance on associations with physical activity outcomes. An internationally-developed set of objective BEMs using three different spatial buffering techniques were used to evaluate the relative differences in resulting explanatory power on self-reported physical activity outcomes. BEMs were developed in five countries using 'sausage,' 'detailed-trimmed,' and 'detailed,' network buffers at a distance of 1 km around participant household addresses (n = 5883). BEM values were significantly different (p < 0.05) for 96% of sausage versus detailed-trimmed buffer comparisons and 89% of sausage versus detailed network buffer comparisons. Results showed that BEM coefficients in physical activity models did not differ significantly across buffering methods, and in most cases BEM associations with physical activity outcomes had the same level of statistical significance across buffer types. However, BEM coefficients differed in significance for 9% of the sausage versus detailed models, which may warrant further investigation. Results of this study inform the selection of spatial buffering methods to estimate physical activity outcomes using an internationally consistent set of BEMs. Using three different network-based buffering methods, the findings indicate significant variation among BEM values, however associations with physical activity outcomes were similar across each buffering technique. The study advances knowledge by presenting consistently assessed relationships between three different network buffer types and utilitarian travel, sedentary behavior, and leisure-oriented physical activity outcomes.
NASA Astrophysics Data System (ADS)
Ma, Zhen; Wan, Rong; Song, Xiefa; Gao, Lei
2013-09-01
Different culture methods may affect the intensive culture system of Pacific white shrimp ( Litopenaeus vannamei) regarding water quality and growth and economic performance. This study evaluated the potential effects of three culture methods through cultivation of juvenile shrimps under consistent tank management conditions for 84 d. The three methods involved shrimp cultivation in different tanks, i.e., outdoor tanks with cement bottom (mode-C), greenhouse tanks with cement bottom (mode-G) and outdoor tanks with mud-substrate (mode-M). Results showed that water temperature was significantly higher in mode-G than that in mode-C ( P < 0.05). In contrast to the other two treatments, mode-M had stable pH after 50 d cultivation of shrimps. In the mid-late period, the average concentrations of TAN, NO2-N, DIP and COD were significantly lower in mode-M and mode-G compared with those in mode-C ( P < 0.05). Despite lack of differences in the final shrimp weight among different treatments ( P > 0.05), mode-M had significantly higher shrimp yield, survival rate and feed conversion rate ( P < 0.05) than other modes. There were significant differences in revenue and net return among different treatments ( P < 0.05). These demonstrated that the treatments of mode-G and mode-M were conductive to the intensive culture system of L. vannamei.
Döring, Sophie; Arzi, Boaz; Barich, Catherine R; Hatcher, David C; Kass, Philip H; Verstraete, Frank J M
2018-01-01
OBJECTIVE To evaluate the diagnostic yield of dental radiography (Rad method) and 3 cone-beam CT (CBCT) methods for the identification of predefined anatomic landmarks in brachycephalic dogs. ANIMALS 19 client-owned brachycephalic dogs admitted for evaluation and treatment of dental disease. PROCEDURES 26 predefined anatomic landmarks were evaluated separately by use of the RAD method and 3 CBCT software modules (serial CBCT slices and custom cross sections, tridimensional rendering, and reconstructed panoramic views). A semiquantitative scoring system was used, and mean scores were calculated for each anatomic landmark and imaging method. The Friedman test was used to evaluate values for significant differences in diagnostic yield. For values that were significant, the Wilcoxon signed rank test was used with the Bonferroni-Holm multiple comparison adjustment to determine significant differences among each of the 6 possible pairs of diagnostic methods. RESULTS Differences of diagnostic yield among the Rad and 3 CBCT methods were significant for 19 of 26 anatomic landmarks. For these landmarks, Rad scores were significantly higher than scores for reconstructed panoramic views for 4 of 19 anatomic landmarks, but Rad scores were significantly lower than scores for reconstructed panoramic views for 8 anatomic landmarks, tridimensional rendering for 18 anatomic landmarks, and serial CBCT slices and custom cross sections for all 19 anatomic landmarks. CONCLUSIONS AND CLINICAL RELEVANCE CBCT methods were better suited than dental radiography for the identification of anatomic landmarks in brachycephalic dogs. Results of this study can serve as a basis for CBCT evaluation of dental disorders in brachycephalic dogs.
A comparison study of different facial soft tissue analysis methods.
Kook, Min-Suk; Jung, Seunggon; Park, Hong-Ju; Oh, Hee-Kyun; Ryu, Sun-Youl; Cho, Jin-Hyoung; Lee, Jae-Seo; Yoon, Suk-Ja; Kim, Min-Soo; Shin, Hyo-Keun
2014-07-01
The purpose of this study was to evaluate several different facial soft tissue measurement methods. After marking 15 landmarks in the facial area of 12 mannequin heads of different sizes and shapes, facial soft tissue measurements were performed by the following 5 methods: Direct anthropometry, Digitizer, 3D CT, 3D scanner, and DI3D system. With these measurement methods, 10 measurement values representing the facial width, height, and depth were determined twice with a one week interval by one examiner. These data were analyzed with the SPSS program. The position created based on multi-dimensional scaling showed that direct anthropometry, 3D CT, digitizer, 3D scanner demonstrated relatively similar values, while the DI3D system showed slightly different values. All 5 methods demonstrated good accuracy and had a high coefficient of reliability (>0.92) and a low technical error (<0.9 mm). The measured value of the distance between the right and left medial canthus obtained by using the DI3D system was statistically significantly different from that obtained by using the digital caliper, digitizer and laser scanner (p < 0.05), but the other measured values were not significantly different. On evaluating the reproducibility of measurement methods, two measurement values (Ls-Li, G-Pg) obtained by using direct anthropometry, one measurement value (N'-Prn) obtained by using the digitizer, and four measurement values (EnRt-EnLt, AlaRt-AlaLt, ChRt-ChLt, Sn-Pg) obtained by using the DI3D system, were statistically significantly different. However, the mean measurement error in every measurement method was low (<0.7 mm). All measurement values obtained by using the 3D CT and 3D scanner did not show any statistically significant difference. The results of this study show that all 3D facial soft tissue analysis methods demonstrate favorable accuracy and reproducibility, and hence they can be used in clinical practice and research studies. Copyright © 2013 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Cross, Alan; Collard, Mark; Nelson, Andrew
2008-01-01
The conventional method of estimating heat balance during locomotion in humans and other hominins treats the body as an undifferentiated mass. This is problematic because the segments of the body differ with respect to several variables that can affect thermoregulation. Here, we report a study that investigated the impact on heat balance during locomotion of inter-segment differences in three of these variables: surface area, skin temperature and rate of movement. The approach adopted in the study was to generate heat balance estimates with the conventional method and then compare them with heat balance estimates generated with a method that takes into account inter-segment differences in surface area, skin temperature and rate of movement. We reasoned that, if the hypothesis that inter-segment differences in surface area, skin temperature and rate of movement affect heat balance during locomotion is correct, the estimates yielded by the two methods should be statistically significantly different. Anthropometric data were collected on seven adult male volunteers. The volunteers then walked on a treadmill at 1.2 m/s while 3D motion capture cameras recorded their movements. Next, the conventional and segmented methods were used to estimate the volunteers' heat balance while walking in four ambient temperatures. Lastly, the estimates produced with the two methods were compared with the paired t-test. The estimates of heat balance during locomotion yielded by the two methods are significantly different. Those yielded by the segmented method are significantly lower than those produced by the conventional method. Accordingly, the study supports the hypothesis that inter-segment differences in surface area, skin temperature and rate of movement impact heat balance during locomotion. This has important implications not only for current understanding of heat balance during locomotion in hominins but also for how future research on this topic should be approached. PMID:18560580
Cross, Alan; Collard, Mark; Nelson, Andrew
2008-06-18
The conventional method of estimating heat balance during locomotion in humans and other hominins treats the body as an undifferentiated mass. This is problematic because the segments of the body differ with respect to several variables that can affect thermoregulation. Here, we report a study that investigated the impact on heat balance during locomotion of inter-segment differences in three of these variables: surface area, skin temperature and rate of movement. The approach adopted in the study was to generate heat balance estimates with the conventional method and then compare them with heat balance estimates generated with a method that takes into account inter-segment differences in surface area, skin temperature and rate of movement. We reasoned that, if the hypothesis that inter-segment differences in surface area, skin temperature and rate of movement affect heat balance during locomotion is correct, the estimates yielded by the two methods should be statistically significantly different. Anthropometric data were collected on seven adult male volunteers. The volunteers then walked on a treadmill at 1.2 m/s while 3D motion capture cameras recorded their movements. Next, the conventional and segmented methods were used to estimate the volunteers' heat balance while walking in four ambient temperatures. Lastly, the estimates produced with the two methods were compared with the paired t-test. The estimates of heat balance during locomotion yielded by the two methods are significantly different. Those yielded by the segmented method are significantly lower than those produced by the conventional method. Accordingly, the study supports the hypothesis that inter-segment differences in surface area, skin temperature and rate of movement impact heat balance during locomotion. This has important implications not only for current understanding of heat balance during locomotion in hominins but also for how future research on this topic should be approached.
The Activity of Antimicrobial Surfaces Varies by Testing Protocol Utilized
Campos, Matias D.; Zucchi, Paola C.; Phung, Ann; Leonard, Steven N.; Hirsch, Elizabeth B.
2016-01-01
Background Contaminated hospital surfaces are an important source of nosocomial infections. A major obstacle in marketing antimicrobial surfaces is a lack of efficacy data based on standardized testing protocols. Aim We compared the efficacy of multiple testing protocols against several “antimicrobial” film surfaces. Methods Four clinical isolates were used: one Escherichia coli, one Klebsiella pneumoniae, and two Staphylococcus aureus strains. Two industry methods (modified ISO 22196 and ASTM E2149), a “dried droplet”, and a “transfer” method were tested against two commercially available antimicrobial films, one film in development, an untreated control, and a positive (silver) control film. At 2 (only ISO) and 24 hours following inoculation, bacteria were collected from film surfaces and enumerated. Results Compared to untreated films in all protocols, there were no significant differences in recovery on either commercial brand at 2 or 24 hours after inoculation. The silver surface demonstrated significant microbicidal activity (mean loss 4.9 Log10 CFU/ml) in all methods and time points with the exception of 2 hours in the ISO protocol and the transfer method. Using our novel droplet method, no differences between placebo and active surfaces were detected. The surface in development demonstrated variable activity depending on method, organism, and time point. The ISO demonstrated minimal activity at 2 hours but significant activity at 24 hours (mean 4.5 Log10 CFU/ml difference versus placebo). The ASTEM protocol exhibited significant differences in recovery of staphylococci (mean 5 Log10 CFU/ml) but not Gram-negative isolates (10 fold decrease). Minimal activity was observed with this film in the transfer method. Conclusions Varying results between protocols suggested that efficacy of antimicrobial surfaces cannot be easily and reproducibly compared. Clinical use should be considered and further development of representative methods is needed. PMID:27494336
Comparison of cervical dysplasia treatment with leep-loop method and CO2 laser vaporization
NASA Astrophysics Data System (ADS)
Wozniak, Jakub; Rzymski, Pawel; Opala, Tomasz; Wilczak, Maciej; Sajdak, Stefan
2003-10-01
There are several methods of treating cervical dysplasia, including surgical and electric conisation, laservaporisation. The aim of our study was to evaluate leep-loop method and laservaporisation wtih CO2 laser. Material consisted of 49 women, 28 underwent leep-loop conisation and 21 lavervaporisation. The effectiveness of laser treatment was 90,4% and with leep-loop 96,4%, but the difference was not statistically significant. Mean time of wound healing and frequency of pain was shorter after laser treatment, but the differences were not statistically significant. Conclusions: Effect treatment with both methods is comparable.
Hemodialysis-associated neutropenia and hypoxemia: the effect of dialyzer membrane materials.
Hakim, R M; Lowrie, E G
1982-01-01
The fall in white blood cells (WBC) and arterial oxygen pressure that occurs during hemodialysis was investigated as a function of different dialysis membranes and different sterilization methods. 8 chronic hemodialysis patients were studied and each was dialyzed with three different membranes: cellulosic hollow fiber, polyacrylonitrile flat sheet and polymethylmethacrylate hollow fiber. Each dialyzer was studied with a dry sterilization method and after formalin treatment. Arterialized blood gas, bicarbonate and WBC were drawn at various intervals throughout dialysis. The effect of the sterilization method was minimal. Cellulosic membranes were shown to cause significantly more neutropenia (p less than 0.001) and hypoxemia (p less than 0.01) than the other two membranes. No significant differences was seen in pH, PCO2 and bicarbonate. The results indicate differences in biocompatibility between different membranes. Clinical implications are discussed.
Kim, Haroo; Kak, Hwang-Bo; Kim, Boin
2014-01-01
[Purpose] The purpose of this study was to compare the effect of childbirth delivery method on vaginal pressure and abdominal thickness during the Valsalva maneuver (VAL). [Subjects] Thirty healthy female volunteers (26–39 years of age) were selected for this research. Their delivery histories were: nulliparous 10, vaginal delivery 10, and Cesarean delivery 10. None of the participants had a history of incontinence. [Methods] In the crook-lying position, a perineometer probe was inserted into the vagina and the transducer was placed transversely on the right side of the body during the Valsalva maneuver. [Results] There were significant differences in the thickness of the transverses abdominis (TrA) between in all the groups rest and the Valsalva maneuver, and there were significant differences in the internus oblique (IO) in the nulliparous group. During the Valsalva maneuver, there were significant differences in the TrA between the nulliparous group and the vaginal delivery group, and there were significant differences in the IO between the nulliparous delivery group and the vaginal delivery group, and between the nulliparous group and the Cesarean section group. Delivery history changed vaginal pressure, and there were significant differences between the nulliparous group and the vaginal delivery group, and between the nulliparous group and the Cesarean delivery group. [Conclusion] Pregnancy and delivery method may affect pelvic floor and abdominal muscles during the Valsalva maneuver. PMID:24707104
Evaluation of methods to assess physical activity in free-living conditions.
Leenders, N Y; Sherman, W M; Nagaraja, H N; Kien, C L
2001-07-01
The purpose of this study was to compare different methods of measuring physical activity (PA) in women by the doubly labeled water method (DLW). Thirteen subjects participated in a 7-d protocol during which total daily energy expenditure (TDEE) was measured with DLW. Body composition, basal metabolic rate (BMR), and peak oxygen consumption were also measured. Physical activity-related energy expenditure (PAEE) was then calculated by subtracting measured BMR and the estimated thermic effect of food from TDEE. Simultaneously, over the 7 d, PA was assessed via a 7-d Physical Activity Recall questionnaire (PAR), and subjects wore secured at the waist, a Tritrac-R3D (Madison, WI), a Computer Science Application Inc. activity monitor (CSA; Shalimar, FL), and a Yamax Digi Walker-500 (Tokyo, Japan). Pearson-product moment correlations were calculated to determine the relationships among the different methods for estimating PAEE. Paired t-tests with appropriate adjustments were used to compare the different methods with DLW-PAEE. There was no significant difference between PAEE determined from PAR and DLW. The differences between the two methods ranged from -633 to 280 kcal.d(-1). Compared with DLW, PAEE determined from CSA, Tritrac, and Yamax was significantly underestimated by 59% (-495 kcal.d(-1)), 35% (-320 kcal.d(-1)) and 59% (-497 kcal.d(-1)), respectively. VO2peak explained 43% of the variation in DLW-PAEE. Although the group average for PAR-PAEE agreed with DLW-PAEE, there were differences in the methods among the subjects. PAEE determined by Tritrac, CSA, and Yamax significantly underestimate free-living PAEE in women.
2017-01-01
PURPOSE The purposes of this study were to evaluate the marginal and internal gaps, and the potential clinical applications of three different methods of dental prostheses fabrication, and to compare the prostheses prepared using the silicone replica technique (SRT) and those prepared using the three-dimensional superimposition analysis (3DSA). MATERIALS AND METHODS Five Pekkton, lithium disilicate, and zirconia crowns were each manufactured and tested using both the SRT and the two-dimensional section of the 3DSA. The data were analyzed with the nonparametric version of a two-way analysis of variance using rank-transformed values and the Tukey's post-hoc test (α = .05). RESULTS Significant differences were observed between the fabrication methods in the marginal gap (P < .010), deep chamfer (P < .001), axial wall (P < .001), and occlusal area (P < .001). A significant difference in the occlusal area was found between the two measurement methods (P < .030), whereas no significant differences were found in the marginal gap (P > .350), deep chamfer (P > .719), and axial wall (P > .150). As the 3DSA method is three-dimensional, it allows for the measurement of arbitrary points. CONCLUSION All of the three fabrication methods are valid for measuring clinical objectives because they produced prostheses within the clinically acceptable range. Furthermore, a three-dimensional superimposition analysis verification method such as the silicone replica technique is also applicable in clinical settings. PMID:28680546
STS-based education in non-majors college biology
NASA Astrophysics Data System (ADS)
Henderson, Phyllis Lee
The study explored the effect of the science-technology-society (STS) and traditional teaching methods in non-majors biology classes at a community college. It investigated the efficacy of the two methods in developing cognitive abilities at Bloom's first three levels of learning. It compared retention rates in classes taught in the two methods. Changes in student attitude relating to anxiety, fear, and interest in biology were explored. The effect of each method on grade attainment among men and women was investigated. The effect of each method on grade attainment among older and younger students was examined. Results of the study indicated that no significant differences, relating to retention or student attitude, existed in classes taught in the two methods. The study found no significant cognitive gains at Bloom's first three levels in classes taught in the traditional format. In the STS classes no significant gains were uncovered at Bloom's first level of cognition. Statistically significant gains were found in the STS classes at Bloom's second and third levels of cognition. In the classes taught in the traditional format no difference was identified in grade attainment between males and females. In the STS-based classes a small correlational difference between males and females was found with males receiving lower grades than expected. No difference in grade attainment was found between older and younger students taught in the traditional format. In the STS-based classes a small statistically significant difference in grade attainment was uncovered between older and younger students with older students receiving more A's and fewer C's than expected. This study found no difference in the grades of older, female students as compared to all other students in the traditionally taught classes. A weak statistically significant difference was discovered between grade attainment of older, female students and all other students in the STS classes with older, female students earning more A's and fewer C's than expected. It was concluded that among the students examined in this investigation STS teaching methods enhanced cognitive gains at Bloom's second and third levels of cognition. STS also strengthened grade attainment among older students and female students. Recommendations for further study included replication of the study to include a larger sample size, other types of institutions, and other academic disciplines in science. Expansion of the study to Bloom's fourth and fifth levels, use of a standardized testing instruments to determine attitude, analysis using qualitative methods of investigation, and refinement of the study to provide a true experimental design were also suggested.
[Cancer nursing care education programs: the effectiveness of different teaching methods].
Cheng, Yun-Ju; Kao, Yu-Hsiu
2012-10-01
In-service education affects the quality of cancer care directly. Using classroom teaching to deliver in-service education is often ineffective due to participants' large workload and shift requirements. This study evaluated the learning effectiveness of different teaching methods in the dimensions of knowledge, attitude, and learning satisfaction. This study used a quasi-experimental study design. Participants were cancer ward nurses working at one medical center in northern Taiwan. Participants were divided into an experimental group and control group. The experimental group took an e-learning course and the control group took a standard classroom course using the same basic course material. Researchers evaluated the learning efficacy of each group using a questionnaire based on the quality of cancer nursing care learning effectiveness scale. All participants answered the questionnaire once before and once after completing the course. (1) Post-test "knowledge" scores for both groups were significantly higher than pre-test scores for both groups. Post-test "attitude" scores were significantly higher for the control group, while the experimental group reported no significant change. (2) after a covariance analysis of the pre-test scores for both groups, the post-test score for the experimental group was significantly lower than the control group in the knowledge dimension. Post-test scores did not differ significantly from pre-test scores for either group in the attitude dimension. (3) Post-test satisfaction scores between the two groups did not differ significantly with regard to teaching methods. The e-learning method, however, was demonstrated as more flexible than the classroom teaching method. Study results demonstrate the importance of employing a variety of teaching methods to instruct clinical nursing staff. We suggest that both classroom teaching and e-learning instruction methods be used to enhance the quality of cancer nursing care education programs. We also encourage that interactivity between student and instructor be incorporated into e-learning course designs to enhance effectiveness.
Bastías, José M; Balladares, Pamela; Acuña, Sergio; Quevedo, Roberto; Muñoz, Ociel
2017-01-01
The effect of four cooking methods was evaluated for proximate composition, fatty acid, calcium, iron, and zinc content in salmon and Chilean jack mackerel. The moisture content of steamed salmon decreased (64.94%) compared to the control (68.05%); a significant decrease was observed in Chilean jack mackerel in all the treatments when compared to the control (75.37%). Protein content in both salmon and Chilean jack mackerel significantly increased under the different treatments while the most significant decrease in lipids was found in oven cooking and canning for salmon and microwaving for Chilean jack mackerel. Ash concentration in both salmon and Chilean jack mackerel did not reveal any significant differences. Iron and calcium content only had significant changes in steaming while zinc did not undergo any significant changes in the different treatments. Finally, no drastic changes were observed in the fatty acid profile in both salmon and Chilean jack mackerel.
Balladares, Pamela; Acuña, Sergio; Quevedo, Roberto; Muñoz, Ociel
2017-01-01
The effect of four cooking methods was evaluated for proximate composition, fatty acid, calcium, iron, and zinc content in salmon and Chilean jack mackerel. The moisture content of steamed salmon decreased (64.94%) compared to the control (68.05%); a significant decrease was observed in Chilean jack mackerel in all the treatments when compared to the control (75.37%). Protein content in both salmon and Chilean jack mackerel significantly increased under the different treatments while the most significant decrease in lipids was found in oven cooking and canning for salmon and microwaving for Chilean jack mackerel. Ash concentration in both salmon and Chilean jack mackerel did not reveal any significant differences. Iron and calcium content only had significant changes in steaming while zinc did not undergo any significant changes in the different treatments. Finally, no drastic changes were observed in the fatty acid profile in both salmon and Chilean jack mackerel. PMID:28686742
Gill, Christina; Blow, Frances; Darby, Alistair C.
2016-01-01
Background Recent studies on the vaginal microbiota have employed molecular techniques such as 16S rRNA gene sequencing to describe the bacterial community as a whole. These techniques require the lysis of bacterial cells to release DNA before purification and PCR amplification of the 16S rRNA gene. Currently, methods for the lysis of bacterial cells are not standardised and there is potential for introducing bias into the results if some bacterial species are lysed less efficiently than others. This study aimed to compare the results of vaginal microbiota profiling using four different pretreatment methods for the lysis of bacterial samples (30 min of lysis with lysozyme, 16 hours of lysis with lysozyme, 60 min of lysis with a mixture of lysozyme, mutanolysin and lysostaphin and 30 min of lysis with lysozyme followed by bead beating) prior to chemical and enzyme-based DNA extraction with a commercial kit. Results After extraction, DNA yield did not significantly differ between methods with the exception of lysis with lysozyme combined with bead beating which produced significantly lower yields when compared to lysis with the enzyme cocktail or 30 min lysis with lysozyme only. However, this did not result in a statistically significant difference in the observed alpha diversity of samples. The beta diversity (Bray-Curtis dissimilarity) between different lysis methods was statistically significantly different, but this difference was small compared to differences between samples, and did not affect the grouping of samples with similar vaginal bacterial community structure by hierarchical clustering. Conclusions An understanding of how laboratory methods affect the results of microbiota studies is vital in order to accurately interpret the results and make valid comparisons between studies. Our results indicate that the choice of lysis method does not prevent the detection of effects relating to the type of vaginal bacterial community one of the main outcome measures of epidemiological studies. However, we recommend that the same method is used on all samples within a particular study. PMID:27643503
Measuring the effectiveness of patient-chosen reminder methods in a private orthodontic practice.
Wegrzyniak, Lauren M; Hedderly, Deborah; Chaudry, Kishore; Bollu, Prashanti
2018-05-01
To evaluate the effectiveness of patient-chosen appointment reminder methods (phone call, e-mail, or SMS text) in reducing no-show rates. This was a retrospective case study that determined the correlation between patient-chosen appointment reminder methods and no-show rates in a private orthodontic practice. This study was conducted in a single office location of a multioffice private orthodontic practice using data gathered in 2015. The subjects were patients who self-selected the appointment reminder method (phone call, e-mail, or SMS text). Patient appointment data were collected over a 6-month period. Patient attendance was analyzed with descriptive statistics to determine any significant differences among patient-chosen reminder methods. There was a total of 1193 appointments with an average no-show rate of 2.43% across the three reminder methods. No statistically significant differences ( P = .569) were observed in the no-show rates between the three methods: phone call (3.49%), e-mail (2.68%), and SMS text (1.90%). The electronic appointment reminder methods (SMS text and e-mail) had lower no-show rates compared with the phone call method, with SMS text having the lowest no-show rate of 1.90%. However, since no significant differences were observed between the three patient-chosen reminder methods, providers may want to allow patients to choose their reminder method to decrease no-shows.
Comparison of Anaerobic Susceptibility Results Obtained by Different Methods
Rosenblatt, J. E.; Murray, P. R.; Sonnenwirth, A. C.; Joyce, J. L.
1979-01-01
Susceptibility tests using 7 antimicrobial agents (carbenicillin, chloramphenicol, clindamycin, penicillin, cephalothin, metronidazole, and tetracycline) were run against 35 anaerobes including Bacteroides fragilis (17), other gram-negative bacilli (7), clostridia (5), peptococci (4), and eubacteria (2). Results in triplicate obtained by the microbroth dilution method and the aerobic modification of the broth disk method were compared with those obtained with an agar dilution method using Wilkins-Chalgren agar. Media used in the microbroth dilution method included Wilkins-Chalgren broth, brain heart infusion broth, brucella broth, tryptic soy broth, thioglycolate broth, and Schaedler's broth. A result differing by more than one dilution from the Wilkins-Chalgren agar result was considered a discrepancy, and when there was a change in susceptibility status this was termed a significant discrepancy. The microbroth dilution method using Wilkins-Chalgren broth and thioglycolate broth produced the fewest total discrepancies (22 and 24, respectively), and Wilkins-Chalgren broth, thioglycolate, and Schaedler's broth had the fewest significant discrepancies (6, 5, and 5, respectively). With the broth disk method, there were 15 significant discrepancies, although half of these were with tetracycline, which was the antimicrobial agent associated with the highest number of significant discrepancies (33), considering all of the test methods and media. PMID:464560
Grady, Cynthia D; Dehlendorf, Christine; Cohen, Elan D; Schwarz, E Bimla; Borrero, Sonya
2015-07-01
To evaluate racial/ethnic differences in contraceptive use among women who do not desire future pregnancy. We used the 2006-2010 National Survey of Family Growth to examine the associations between race/ethnicity and 1) use of any contraceptive method at last heterosexual intercourse and 2) effectiveness of contraceptive method used among women who stated that they did not desire any (more) children. We conducted multivariable logistic regression to assess the independent effect of race/ethnicity on these outcomes, adjusting for socio-demographic factors, reproductive characteristics, and indicators of healthcare access and utilization. The study sample consisted of 2900 women, aged 15-44 years. The vast majority of women (91.2%) used contraception at last sex, although this varied significantly by race/ethnicity (p<.01). In the fully adjusted model controlling for demographic and reproductive characteristics as well as healthcare access, compared to whites, black women were significantly less likely to use any contraception at last sex (OR: 0.43; 95% CI: 0.27-0.73), while there was no significant difference for Hispanic women (OR: 0.95; 95% CI: 0.52-1.72). Among women who used a method at last sex, the type of contraceptive method varied significantly by race/ethnicity in bivariate analysis (p<.01), although most women (59%) used a highly effective method. In the fully adjusted model, racial/ethnic differences were no longer significant. In this nationally representative cohort of women who report that they do not desire (more) children, black women were significantly less likely than white women to use any contraception at last intercourse; this difference did not appear to be due to differential access to health care. Significant racial/ethnic differences exist in contraceptive use among women who have completed childbearing, which do not appear to be explained by differential socioeconomic status, reproductive characteristics or utilization of healthcare. Other factors, including social mobility and locus of reproductive control, that may contribute to these variations should be further explored. Published by Elsevier Inc.
40 CFR Appendix A to Part 63 - Test Methods
Code of Federal Regulations, 2010 CFR
2010-07-01
... components by a different analyst). 3.3Surrogate Reference Materials. The analyst may use surrogate compounds... the variance of the proposed method is significantly different from that of the validated method by... variables can be determined in eight experiments rather than 128 (W.J. Youden, Statistical Manual of the...
Plant selection for ethnobotanical uses on the Amalfi Coast (Southern Italy).
Savo, V; Joy, R; Caneva, G; McClatchey, W C
2015-07-15
Many ethnobotanical studies have investigated selection criteria for medicinal and non-medicinal plants. In this paper we test several statistical methods using different ethnobotanical datasets in order to 1) define to which extent the nature of the datasets can affect the interpretation of results; 2) determine if the selection for different plant uses is based on phylogeny, or other selection criteria. We considered three different ethnobotanical datasets: two datasets of medicinal plants and a dataset of non-medicinal plants (handicraft production, domestic and agro-pastoral practices) and two floras of the Amalfi Coast. We performed residual analysis from linear regression, the binomial test and the Bayesian approach for calculating under-used and over-used plant families within ethnobotanical datasets. Percentages of agreement were calculated to compare the results of the analyses. We also analyzed the relationship between plant selection and phylogeny, chorology, life form and habitat using the chi-square test. Pearson's residuals for each of the significant chi-square analyses were examined for investigating alternative hypotheses of plant selection criteria. The three statistical analysis methods differed within the same dataset, and between different datasets and floras, but with some similarities. In the two medicinal datasets, only Lamiaceae was identified in both floras as an over-used family by all three statistical methods. All statistical methods in one flora agreed that Malvaceae was over-used and Poaceae under-used, but this was not found to be consistent with results of the second flora in which one statistical result was non-significant. All other families had some discrepancy in significance across methods, or floras. Significant over- or under-use was observed in only a minority of cases. The chi-square analyses were significant for phylogeny, life form and habitat. Pearson's residuals indicated a non-random selection of woody species for non-medicinal uses and an under-use of plants of temperate forests for medicinal uses. Our study showed that selection criteria for plant uses (including medicinal) are not always based on phylogeny. The comparison of different statistical methods (regression, binomial and Bayesian) under different conditions led to the conclusion that the most conservative results are obtained using regression analysis.
Evaluation of saliva collection devices for the analysis of proteins.
Topkas, Eleni; Keith, Patricia; Dimeski, Goce; Cooper-White, Justin; Punyadeera, Chamindie
2012-07-11
Human saliva mirrors the body's health and can be collected non-invasively, does not require specialized skills and is suitable for large population based screening programs. The aims were twofold: to evaluate the suitability of commercially available saliva collection devices for quantifying proteins present in saliva and to provide levels for C-reactive protein (CRP), myoglobin, and immunoglobin E (IgE) in saliva of healthy individuals as a baseline for future studies. Saliva was collected from healthy volunteers (n=17, ages 18-33years). The following collection methods were evaluated: drool; Salimetrics® Oral Swab (SOS); Salivette® Cotton and Synthetic (Sarstedt) and Greiner Bio-One Saliva Collection System (GBO SCS®). We used AlphaLISA® assays to measure CRP, IgE and myoglobin levels in human saliva. Significant (p<0.05) differences in the salivary flow rates were observed based on the method of collection, i.e. salivary flow rates were significantly lower (p<0.05) in unstimulated saliva (i.e. drool and SOS), when compared with mechanically stimulated methods (p<0.05) (Salivette® Cotton and Synthetic) and acid stimulated method (p<0.05) (SCS®). Saliva collected using SOS yielded significantly (p<0.05) lower concentrations of myoglobin and CRP, whilst, saliva collected using the Salivette® Cotton and Synthetic swab yielded significantly (p<0.05) lower myoglobin and IgE concentrations respectively. The results demonstrated significantly relevant differences in analyte levels based on the collection method. Significant differences in the salivary flow rates were also observed depending on the saliva collection method. The data provide preliminary baseline values for salivary CRP, myoglobin, and IgE levels in healthy participants and based on the collection method. Copyright © 2012 Elsevier B.V. All rights reserved.
Rowe, Philip
2013-01-01
Residual limb shape capturing (Casting) consistency has a great influence on the quality of socket fit. Magnetic Resonance Imaging was used to establish a reliable reference grid for intercast and intracast shape and volume consistency of two common casting methods, Hands-off and Hands-on. Residual limbs were cast for twelve people with a unilateral below knee amputation and scanned twice for each casting concept. Subsequently, all four volume images of each amputee were semiautomatically segmented and registered to a common coordinate system using the tibia and then the shape and volume differences were calculated. The results show that both casting methods have intra cast volume consistency and there is no significant volume difference between the two methods. Inter- and intracast mean volume differences were not clinically significant based on the volume of one sock criteria. Neither the Hands-off nor the Hands-on method resulted in a consistent residual limb shape as the coefficient of variation of shape differences was high. The resultant shape of the residual limb in the Hands-off casting was variable but the differences were not clinically significant. For the Hands-on casting, shape differences were equal to the maximum acceptable limit for a poor socket fit. PMID:24348164
Takikawa, Satoshi; Bauer, Thomas W; Kambic, Helen; Togawa, Daisuke
2003-04-01
In the United States, demineralized bone matrix (DBM) is considered a transplantable tissue and therefore is regulated primarily by the American Association of Tissue Banks. Even though DBM is not subjected to the same regulations relative to performance claims as medical devices are, one would expect different processing methods might yield DBM preparations of different osteoinductive potential. The purpose of this study was to use an established athymic rat model to compare the osteoinductive properties of two commercially available human DBMs prepared using different methods but having essentially identical product claims. Sixteen female athymic rats were used to test equivalent volumes of two lots each of Grafton Putty (Osteotech, Inc., Eatontown, NJ), Osteofil (Regeneration Technologies, Inc., Alachua, FL), and rat DBM. At 28 days after implantation, qualitative and semiquantitative microscopy showed no significant differences in bone formation between the two lots from each source, but rat DBM produced significantly more bone than Grafton, which produced significantly more bone than Osteofil. Our results suggest that methods of graft processing may represent a greater source of variability than do differences among individual donors. Whether these differences relate to methods of demineralization, carrier, dose of DBM per volume, or to some other factor remains to be determined. Copyright 2003 Wiley Periodicals, Inc.
Safari, Mohammad Reza; Rowe, Philip; McFadyen, Angus; Buis, Arjan
2013-01-01
Residual limb shape capturing (Casting) consistency has a great influence on the quality of socket fit. Magnetic Resonance Imaging was used to establish a reliable reference grid for intercast and intracast shape and volume consistency of two common casting methods, Hands-off and Hands-on. Residual limbs were cast for twelve people with a unilateral below knee amputation and scanned twice for each casting concept. Subsequently, all four volume images of each amputee were semiautomatically segmented and registered to a common coordinate system using the tibia and then the shape and volume differences were calculated. The results show that both casting methods have intra cast volume consistency and there is no significant volume difference between the two methods. Inter- and intracast mean volume differences were not clinically significant based on the volume of one sock criteria. Neither the Hands-off nor the Hands-on method resulted in a consistent residual limb shape as the coefficient of variation of shape differences was high. The resultant shape of the residual limb in the Hands-off casting was variable but the differences were not clinically significant. For the Hands-on casting, shape differences were equal to the maximum acceptable limit for a poor socket fit.
The research progress of perforating gun inner wall blind hole machining method
NASA Astrophysics Data System (ADS)
Wang, Zhe; Shen, Hongbing
2018-04-01
Blind hole processing method has been a concerned technical problem in oil, electronics, aviation and other fields. This paper introduces different methods for blind hole machining, focus on machining method for perforating gun inner wall blind hole processing. Besides, the advantages and disadvantages of different methods are also discussed, and the development trend of blind hole processing were introduced significantly.
Ulloa, A; Rodríguez, M H; Rodríguez, A D; Roberts, D R
1997-09-01
The abundance and age structure of Anopheles albimanus populations were estimated by UV updraft light traps and human landing catches within villages and in nearby breeding sites of southern México. Four villages and 5 breeding sites were selected for the study. Light trap and human landing catches were simultaneously carried out in each breeding site and each village. Anopheles albimanus was the most abundant malaria vector caught in breeding sites and in villages. Significant differences in overall An. albimanus abundance among villages and among breeding sites were detected only by human landing catches. In both villages and breeding sites, more mosquitoes were captured by 1 human bait (34.3 +/- 6.3 and 14.6 +/- 2.9, respectively) than by one light trap (15.9 +/- 3.3 and 2.4 +/- 0.3 respectively) collection. After pooling, no significant differences were detected in the abundance estimated by each method in breeding sites and villages. A significant correlation of numbers of specimens between methods was detected. Age structure was different between samples from breeding sites and villages, with more gravid females collected in breeding sites, whereas more nulipars were collected in villages. By collection method, age structure was also different both in breeding sites and in villages. In breeding sites, the percentage of parous females was significantly higher in human landing catches, whereas the percentage of gravid females was significantly higher in light traps. In villages, only the percentage of gravid females was significantly higher in light traps. Our results suggests that UV light traps could be used to measure several entomological parameters of An. albimanus populations because both abundance variations and parity rates were similarly detected by both methods.
Harari, Gil
2014-01-01
Statistic significance, also known as p-value, and CI (Confidence Interval) are common statistics measures and are essential for the statistical analysis of studies in medicine and life sciences. These measures provide complementary information about the statistical probability and conclusions regarding the clinical significance of study findings. This article is intended to describe the methodologies, compare between the methods, assert their suitability for the different needs of study results analysis and to explain situations in which each method should be used.
Chuang, Chi-Cheng; Lin, Shinn-Yn; Pai, Ping-Ching; Yan, Jiun-Lin; Toh, Cheng-Hong; Lee, Shih-Tseng; Wei, Kuo-Chen; Liu, Zhuo-Hao; Chen, Chung-Ming; Wang, Yu-Chi; Lee, Cheng-Chi
2017-01-01
Confirming the status of residual tumors is crucial. In stationary or spontaneous regression cases, early treatments are inappropriate. The long-used geometric calculation formula is 1/2 (length × width × height). However, it yields only rough estimates and is particularly unreliable for irregularly shaped masses. In our study, we attempted to propose a more accurate method. Between 2004 and 2014, 94 patients with pituitary tumors were enrolled in this retrospective study. All patients underwent transsphenoidal surgery and received magnetic resonance imaging (MRI). The pre- and postoperative volumes calculated using the traditional formula were termed A1 and A2, and those calculated using the proposed method were termed O1 and O2, respectively. Wilcoxon signed rank test revealed no significant difference between the A1 and O1 groups (P = 0.1810) but a significant difference between the A2 and O2 groups (P < 0.0001). Significant differences were present in the extent of resection (P < 0.0001), high-grade cavernous sinus invasion (P = 0.0312), and irregular shape (P = 0.0116). Volume is crucial in evaluating tumor status and determining treatment. Therefore, a more scientific method is especially useful when lesions are irregularly shaped or when treatment is determined exclusively based on the tumor volume. PMID:28098212
Liu, Jin-Na; Xie, Xiao-Liang; Yang, Tai-Xin; Zhang, Cun-Li; Jia, Dong-Sheng; Liu, Ming; Wen, Chun-Xiu
2014-04-01
To study the different mature stages and the best processing methods on the quality of Trichosanthes kirilowii seeds. The content of 3,29-dibenzoyl rarounitriol in Trichosanthes kirilowii seeds was determined by HPLC. The sample of different mature stages such as immature, near mature and fully mature and processed by different methods were studied. Fully mature Trichosanthes kirilowii seeds were better than the immatured, and the best processing method was dried under 60degrees C, the content of 3,29-dibenzoyl rarounitriol reached up to 131.63microlg/mL. Different processing methods and different mature stages had a significant influence on the quality of Trichosanthes kirilowii seeds.
Comparison of four different methods for detection of biofilm formation by uropathogens.
Panda, Pragyan Swagatika; Chaudhary, Uma; Dube, Surya K
2016-01-01
Urinary tract infection (UTI) is one of the most common infectious diseases encountered in clinical practice. Emerging resistance of the uropathogens to the antimicrobial agents due to biofilm formation is a matter of concern while treating symptomatic UTI. However, studies comparing different methods for detection of biofilm by uropathogens are scarce. To compare four different methods for detection of biofilm formation by uropathogens. Prospective observational study conducted in a tertiary care hospital. Totally 300 isolates from urinary samples were analyzed for biofilm formation by four methods, that is, tissue culture plate (TCP) method, tube method (TM), Congo Red Agar (CRA) method and modified CRA (MCRA) method. Chi-square test was applied when two or more set of variables were compared. P < 0.05 considered as statistically significant. Considering TCP to be a gold standard method for our study we calculated other statistical parameters. The rate of biofilm detection was 45.6%, 39.3% and 11% each by TCP, TM, CRA and MCRA methods, respectively. The difference between TCP and only CRA/MCRA was significant, but not that between TCP and TM. There was no difference in the rate of biofilm detection between CRA and MCRA in other isolates, but MCRA is superior to CRA for detection of the staphylococcal biofilm formation. TCP method is the ideal method for detection of bacterial biofilm formation by uropathogens. MCRA method is superior only to CRA for detection of staphylococcal biofilm formation.
Twisk, J W R; Hoogendijk, E O; Zwijsen, S A; de Boer, M R
2016-04-01
Within epidemiology, a stepped wedge trial design (i.e., a one-way crossover trial in which several arms start the intervention at different time points) is increasingly popular as an alternative to a classical cluster randomized controlled trial. Despite this increasing popularity, there is a huge variation in the methods used to analyze data from a stepped wedge trial design. Four linear mixed models were used to analyze data from a stepped wedge trial design on two example data sets. The four methods were chosen because they have been (frequently) used in practice. Method 1 compares all the intervention measurements with the control measurements. Method 2 treats the intervention variable as a time-independent categorical variable comparing the different arms with each other. In method 3, the intervention variable is a time-dependent categorical variable comparing groups with different number of intervention measurements, whereas in method 4, the changes in the outcome variable between subsequent measurements are analyzed. Regarding the results in the first example data set, methods 1 and 3 showed a strong positive intervention effect, which disappeared after adjusting for time. Method 2 showed an inverse intervention effect, whereas method 4 did not show a significant effect at all. In the second example data set, the results were the opposite. Both methods 2 and 4 showed significant intervention effects, whereas the other two methods did not. For method 4, the intervention effect attenuated after adjustment for time. Different methods to analyze data from a stepped wedge trial design reveal different aspects of a possible intervention effect. The choice of a method partly depends on the type of the intervention and the possible time-dependent effect of the intervention. Furthermore, it is advised to combine the results of the different methods to obtain an interpretable overall result. Copyright © 2016 Elsevier Inc. All rights reserved.
Assessment of changing interdependencies between human electroencephalograms using nonlinear methods
NASA Astrophysics Data System (ADS)
Pereda, E.; Rial, R.; Gamundi, A.; González, J.
2001-01-01
We investigate the problems that might arise when two recently developed methods for detecting interdependencies between time series using state space embedding are applied to signals of different complexity. With this aim, these methods were used to assess the interdependencies between two electroencephalographic channels from 10 adult human subjects during different vigilance states. The significance and nature of the measured interdependencies were checked by comparing the results of the original data with those of different types of surrogates. We found that even with proper reconstructions of the dynamics of the time series, both methods may give wrong statistical evidence of decreasing interdependencies during deep sleep due to changes in the complexity of each individual channel. The main factor responsible for this result was the use of an insufficient number of neighbors in the calculations. Once this problem was surmounted, both methods showed the existence of a significant relationship between the channels which was mostly of linear type and increased from awake to slow wave sleep. We conclude that the significance of the qualitative results provided for both methods must be carefully tested before drawing any conclusion about the implications of such results.
Simulated families: A test for different methods of family identification
NASA Technical Reports Server (NTRS)
Bendjoya, Philippe; Cellino, Alberto; Froeschle, Claude; Zappala, Vincenzo
1992-01-01
A set of families generated in fictitious impact events (leading to a wide range of 'structure' in the orbital element space have been superimposed to various backgrounds of different densities in order to investigate the efficiency and the limitations of the methods used by Zappala et al. (1990) and by Bendjoya et al. (1990) for identifying asteroid families. In addition, an evaluation of the expected interlopers at different significance levels and the possibility of improving the definition of the level of maximum significant of a given family were analyzed.
Effect of different sulfadimidine addition methods on its degradation behaviour in swine manure.
Ren, Tian-Tian; Li, Xiao-Yang; Wang, Yan; Zou, Yong-De; Liao, Xin-Di; Liang, Juan-Boo; Wu, Yin-Bao
2017-03-01
Sulfadimidine (SM2) is commonly used in the swine industry and enters the environment via faeces. In recent years, advances in the ecotoxicology of SM2 have become a popular research interest with two common research methods including swine manure collection from swine fed with a diet containing SM2 and directly adding SM2. The purpose of this experiment was to compare SM2 degradation behaviour in pig manure with two different SM2 addition methods. The results showed that the degradation half-lives of SM2 in manure from SM2-fed swine treatment were 33.2 and 32.0 days at the initial addition level of SM2 at 32.1 and 64.3 mg/kg, respectively. This was significantly longer than that in manure directly adding SM2 treatment with the half-lives of 21.4 and 14.8 days. The metabolite of SM2 N 4 -acetyl-sulfamethazine occurred in manure from SM2-fed swine treatment but was not detected in directly adding SM2 treatment. The pH in manure from SM2-fed swine treatment was significantly lower than that in directly adding SM2 treatment, but the values of organic carbon, total nitrogen, and electrical conductivity in manure from SM2-fed swine treatment were significantly higher than those in manure directly adding SM2 treatment. Meanwhile, although the copy number of bacteria had no significant difference between two treatments, there was a significant difference in bacteria diversity. Results of the present study demonstrated that the presence of the metabolites, chemical property, and microbial diversity might be the reason for different SM2 degradation behaviours on different addition methods. Thus, the method using manure with SM2 collected from swine could obtain more accurate results for the ecotoxicological study of SM2.
Image scanning fluorescence emission difference microscopy based on a detector array.
Li, Y; Liu, S; Liu, D; Sun, S; Kuang, C; Ding, Z; Liu, X
2017-06-01
We propose a novel imaging method that enables the enhancement of three-dimensional resolution of confocal microscopy significantly and achieve experimentally a new fluorescence emission difference method for the first time, based on the parallel detection with a detector array. Following the principles of photon reassignment in image scanning microscopy, images captured by the detector array were arranged. And by selecting appropriate reassign patterns, the imaging result with enhanced resolution can be achieved with the method of fluorescence emission difference. Two specific methods are proposed in this paper, showing that the difference between an image scanning microscopy image and a confocal image will achieve an improvement of transverse resolution by approximately 43% compared with that in confocal microscopy, and the axial resolution can also be enhanced by at least 22% experimentally and 35% theoretically. Moreover, the methods presented in this paper can improve the lateral resolution by around 10% than fluorescence emission difference and 15% than Airyscan. The mechanism of our methods is verified by numerical simulations and experimental results, and it has significant potential in biomedical applications. © 2017 The Authors Journal of Microscopy © 2017 Royal Microscopical Society.
ERIC Educational Resources Information Center
Cameron, Leanne
2017-01-01
This paper reports on the learning designs, teaching methods and activities most commonly employed within the disciplines in six universities in Australia. The study sought to establish if there were significant differences between the disciplines in learning designs, teaching methods and teaching activities in the current Australian context, as…
Iglesias, Juan Eugenio; Van Leemput, Koen; Augustinack, Jean; Insausti, Ricardo; Fischl, Bruce; Reuter, Martin
2016-01-01
The hippocampal formation is a complex, heterogeneous structure that consists of a number of distinct, interacting subregions. Atrophy of these subregions is implied in a variety of neurodegenerative diseases, most prominently in Alzheimer’s disease (AD). Thanks to the increasing resolution of MR images and computational atlases, automatic segmentation of hippocampal subregions is becoming feasible in MRI scans. Here we introduce a generative model for dedicated longitudinal segmentation that relies on subject-specific atlases. The segmentations of the scans at the different time points are jointly computed using Bayesian inference. All time points are treated the same to avoid processing bias. We evaluate this approach using over 4,700 scans from two publicly available datasets (ADNI and MIRIAD). In test-retest reliability experiments, the proposed method yielded significantly lower volume differences and significantly higher Dice overlaps than the cross-sectional approach for nearly every subregion (average across subregions: 4.5% vs. 6.5%, Dice overlap: 81.8% vs. 75.4%). The longitudinal algorithm also demonstrated increased sensitivity to group differences: in MIRIAD (69 subjects: 46 with AD and 23 controls), it found differences in atrophy rates between AD and controls that the cross sectional method could not detect in a number of subregions: right parasubiculum, left and right presubiculum, right subiculum, left dentate gyrus, left CA4, left HATA and right tail. In ADNI (836 subjects: 369 with AD, 215 with early cognitive impairment – eMCI – and 252 controls), all methods found significant differences between AD and controls, but the proposed longitudinal algorithm detected differences between controls and eMCI and differences between eMCI and AD that the cross sectional method could not find: left presubiculum, right subiculum, left and right parasubiculum, left and right HATA. Moreover, many of the differences that the cross-sectional method already found were detected with higher significance. The presented algorithm will be made available as part of the open-source neuroimaging package FreeSurfer. PMID:27426838
Partitioning of monomethylmercury between freshwater algae and water.
Miles, C J; Moye, H A; Phlips, E J; Sargent, B
2001-11-01
Phytoplankton-water monomethylmercury (MeHg) partition constants (KpI) have been determined in the laboratory for two green algae Selenastrum capricornutum and Cosmarium botrytis, the blue-green algae Schizothrix calcicola, and the diatom Thallasiosira spp., algal species that are commonly found in natural surface waters. Two methods were used to determine KpI, the Freundlich isotherm method and the flow-through/dialysis bag method. Both methods yielded KpI values of about 10(6.6) for S. capricornutum and were not significantly different. The KpI for the four algae studied were similar except for Schizothrix, which was significantly lower than S. capricornutum. The KpI for MeHg and S. capricornutum (exponential growth) was not significantly different in systems with predominantly MeHgOH or MeHgCl species. This is consistent with other studies that show metal speciation controls uptake kinetics, but the reactivity with intracellular components controls steady-state concentrations. Partitioning constants determined with exponential and stationary phase S. capricornutum cells at the same conditions were not significantly different, while the partitioning constant for exponential phase, phosphorus-limited cells was significantly lower, suggesting that P-limitation alters the ecophysiology of S. capricornutum sufficiently to impact partitioning, which may then ultimately affect mercury levels in higher trophic species.
Jo, Ayami; Kanazawa, Manabu; Sato, Yusuke; Iwaki, Maiko; Akiba, Norihisa; Minakuchi, Shunsuke
2015-08-01
To compare the effect of conventional complete dentures (CD) fabricated using two different impression methods on patient-reported outcomes in a randomized controlled trial (RCT). A cross-over RCT was performed with edentulous patients, required maxillomandibular CDs. Mandibular CDs were fabricated using two different methods. The conventional method used a custom tray border moulded with impression compound and a silicone. The simplified used a stock tray and an alginate. Participants were randomly divided into two groups. The C-S group had the conventional method used first, followed by the simplified. The S-C group was in the reverse order. Adjustment was performed four times. A wash out period was set for 1 month. The primary outcome was general patient satisfaction, measured using visual analogue scales, and the secondary outcome was oral health-related quality of life, measured using the Japanese version of the Oral Health Impact Profile for edentulous (OHIP-EDENT-J) questionnaire scores. Twenty-four participants completed the trial. With regard to general patient satisfaction, the conventional method was significantly more acceptable than the simplified. No significant differences were observed between the two methods in the OHIP-EDENT-J scores. This study showed CDs fabricated with a conventional method were significantly more highly rated for general patient satisfaction than a simplified. CDs, fabricated with the conventional method that included a preliminary impression made using alginate in a stock tray and subsequently a final impression made using silicone in a border moulded custom tray resulted in higher general patient satisfaction. UMIN000009875. Copyright © 2015 Elsevier Ltd. All rights reserved.
Timp, Sheila; Karssemeijer, Nico
2004-05-01
Mass segmentation plays a crucial role in computer-aided diagnosis (CAD) systems for classification of suspicious regions as normal, benign, or malignant. In this article we present a robust and automated segmentation technique--based on dynamic programming--to segment mass lesions from surrounding tissue. In addition, we propose an efficient algorithm to guarantee resulting contours to be closed. The segmentation method based on dynamic programming was quantitatively compared with two other automated segmentation methods (region growing and the discrete contour model) on a dataset of 1210 masses. For each mass an overlap criterion was calculated to determine the similarity with manual segmentation. The mean overlap percentage for dynamic programming was 0.69, for the other two methods 0.60 and 0.59, respectively. The difference in overlap percentage was statistically significant. To study the influence of the segmentation method on the performance of a CAD system two additional experiments were carried out. The first experiment studied the detection performance of the CAD system for the different segmentation methods. Free-response receiver operating characteristics analysis showed that the detection performance was nearly identical for the three segmentation methods. In the second experiment the ability of the classifier to discriminate between malignant and benign lesions was studied. For region based evaluation the area Az under the receiver operating characteristics curve was 0.74 for dynamic programming, 0.72 for the discrete contour model, and 0.67 for region growing. The difference in Az values obtained by the dynamic programming method and region growing was statistically significant. The differences between other methods were not significant.
Open Tibial Inlay PCL Reconstruction: Surgical Technique and Clinical Outcomes.
Vellios, Evan E; Jones, Kristofer J; McAllister, David R
2018-06-01
To review the current literature on clinical outcomes following open tibial inlay posterior cruciate ligament (PCL) reconstruction and provide the reader with a detailed description of the author's preferred surgical technique. Despite earlier biomechanical studies which demonstrated superiority of the PCL inlay technique when compared to transtibial techniques, recent longitudinal cohort studies have shown no significant differences in clinical or functional outcomes at 10-year follow-up. Furthermore, no significant clinical differences have been shown between graft types used and/or single- versus double-bundle reconstruction methods. The optimal treatment for the PCL-deficient knee remains unclear. Open tibial inlay PCL reconstruction is safe, reproducible, and avoids the "killer turn" that may potentially lead to graft weakening and failure seen in transtibial reconstruction methods. No significant differences in subjective outcomes or clinical laxity have been shown between single-bundle versus double-bundle reconstruction methods.
Comparing data collected by computerized and written surveys for adolescence health research.
Wu, Ying; Newfield, Susan A
2007-01-01
This study assessed whether data-collection formats, computerized versus paper-and-pencil, affect response patterns and descriptive statistics for adolescent health assessment surveys. Youth were assessed as part of a health risk reduction program. Baseline data from 1131 youth were analyzed. Participants completed the questionnaire either by computer (n = 390) or by paper-and-pencil (n = 741). The rate of returned surveys meeting inclusion requirements was 90.6% and did not differ by methods. However, the computerized method resulted in significantly less incompleteness but more identical responses. Multiple regression indicated that the survey methods did not contribute to problematic responses. The two survey methods yielded similar scale internal reliability and descriptive statistics for behavioral and psychological outcomes, although the computerized method elicited higher reports of some risk items such as carrying a knife, beating up a person, selling drugs, and delivering drugs. Overall, the survey method did not produce a significant difference in outcomes. This provides support for program personnel selecting survey methods based on study goals with confidence that the method of administration will not have a significant impact on the outcome.
NASA Astrophysics Data System (ADS)
Hadi, S.; Artanti, A. N.; Rinanto, Y.; Wahyuni, D. S. C.
2018-04-01
Curcuminoid, consisting of curcumin, demethoxycurcumin and bis demethoxycurcumin, is the major compound in Curcuma longa L. and Curcuma xanthorrhiza rhizome. It has been known to have a potent antioxidants, anticancer, antibacteria activity. Those rhizomes needs to be dried beforehand which influenced the active compounds concentration. The present work was conducted to assess the curcuminoid content of C. longa L. and C. xanthorrhiza based on drying method with Nuclear Magnetic Resonance (NMR) and High Pressure Liquid Chromatography (HPLC)-UVD. Samples were collected and dried using freeze-drying and oven method. The latter is the common method applied in most drying method at herbal medicine preparation procedure. All samples were extracted using 96% ethanol and analyzed using NMR and HPLC-UVD. Curcuminoid as a bioactive compound in the sample exhibited no significant difference and weak significant difference in C. xanthorrhiza and C. longa L., respectively. HLPC-UVD as a reliable analytical method for the quantification is subsequently used to confirm of the data obtained by NMR. It resulted that curcuminoid content showed no significant difference in both samples. This replied that curcuminoids content in both samples were stable into heating process. These results are useful information for simplicia standardization method in pharmaceutical products regarding to preparation procedure.
Interlinking backscatter, grain size and benthic community structure
NASA Astrophysics Data System (ADS)
McGonigle, Chris; Collier, Jenny S.
2014-06-01
The relationship between acoustic backscatter, sediment grain size and benthic community structure is examined using three different quantitative methods, covering image- and angular response-based approaches. Multibeam time-series backscatter (300 kHz) data acquired in 2008 off the coast of East Anglia (UK) are compared with grain size properties, macrofaunal abundance and biomass from 130 Hamon and 16 Clamshell grab samples. Three predictive methods are used: 1) image-based (mean backscatter intensity); 2) angular response-based (predicted mean grain size), and 3) image-based (1st principal component and classification) from Quester Tangent Corporation Multiview software. Relationships between grain size and backscatter are explored using linear regression. Differences in grain size and benthic community structure between acoustically defined groups are examined using ANOVA and PERMANOVA+. Results for the Hamon grab stations indicate significant correlations between measured mean grain size and mean backscatter intensity, angular response predicted mean grain size, and 1st principal component of QTC analysis (all p < 0.001). Results for the Clamshell grab for two of the methods have stronger positive correlations; mean backscatter intensity (r2 = 0.619; p < 0.001) and angular response predicted mean grain size (r2 = 0.692; p < 0.001). ANOVA reveals significant differences in mean grain size (Hamon) within acoustic groups for all methods: mean backscatter (p < 0.001), angular response predicted grain size (p < 0.001), and QTC class (p = 0.009). Mean grain size (Clamshell) shows a significant difference between groups for mean backscatter (p = 0.001); other methods were not significant. PERMANOVA for the Hamon abundance shows benthic community structure was significantly different between acoustic groups for all methods (p ≤ 0.001). Overall these results show considerable promise in that more than 60% of the variance in the mean grain size of the Clamshell grab samples can be explained by mean backscatter or acoustically-predicted grain size. These results show that there is significant predictive capacity for sediment characteristics from multibeam backscatter and that these acoustic classifications can have ecological validity.
2017-01-01
Background The accuracy of radiographic methods for dental age estimation is important for biological growth research and forensic applications. Accuracy of the two most commonly used systems (Demirjian and Willems) has been evaluated with conflicting results. This study investigates the accuracies of these methods for dental age estimation in different populations. Methods A search of PubMed, Scopus, Ovid, Database of Open Access Journals and Google Scholar was undertaken. Eligible studies published before December 28, 2016 were reviewed and analyzed. Meta-analysis was performed on 28 published articles using the Demirjian and/or Willems methods to estimate chronological age in 14,109 children (6,581 males, 7,528 females) age 3–18 years in studies using Demirjian’s method and 10,832 children (5,176 males, 5,656 females) age 4–18 years in studies using Willems’ method. The weighted mean difference at 95% confidence interval was used to assess accuracies of the two methods in predicting the chronological age. Results The Demirjian method significantly overestimated chronological age (p<0.05) in males age 3–15 and females age 4–16 when studies were pooled by age cohorts and sex. The majority of studies using Willems’ method did not report significant overestimation of ages in either sex. Overall, Demirjian’s method significantly overestimated chronological age compared to the Willems method (p<0.05). The weighted mean difference for the Demirjian method was 0.62 for males and 0.72 for females, while that of the Willems method was 0.26 for males and 0.29 for females. Conclusion The Willems method provides more accurate estimation of chronological age in different populations, while Demirjian’s method has a broad application in terms of determining maturity scores. However, accuracy of Demirjian age estimations is confounded by population variation when converting maturity scores to dental ages. For highest accuracy of age estimation, population-specific standards, rather than a universal standard or methods developed on other populations, need to be employed. PMID:29117240
Comparison of three methods for determination of N-nitrosopyrrolidine in fried dry-cured bacon.
Gates, R A; Pensabene, J W; Fiddler, W
1984-01-01
The recently developed Eastern Regional Research Center ( ERRC ) dry column chromatographic procedure for determining N-nitrosopyrrolidine (NPYR) in fried cure-pumped bacon was evaluated for its applicability to fried dry-cured bacon. The method was then compared with 2 established procedures for volatile nitrosamine analysis in cured meat products: the multidetection thermal energy analyzer (MD) method and the mineral oil distillation (MOD) screening procedure. No significant difference (P less than 0.05) in NPYR values was found between the ERRC and MD procedures, but significant differences were found between the ERRC and MOD procedures and between the MOD and MD procedures. No artifactual nitrosamine formation was found in the ERRC procedure, but significant amounts were found in samples analyzed by the MOD procedure. The ERRC method was demonstrated to be rugged and very rapid. It is proposed that the ERRC method replace the MOD method as the official screening procedure for NPYR in fried bacon.
Evaluating fMRI methods for assessing hemispheric language dominance in healthy subjects.
Baciu, Monica; Juphard, Alexandra; Cousin, Emilie; Bas, Jean François Le
2005-08-01
We evaluated two methods for quantifying the hemispheric language dominance in healthy subjects, by using a rhyme detection (deciding whether couple of words rhyme) and a word fluency (generating words starting with a given letter) task. One of methods called "flip method" (FM) was based on the direct statistical comparison between hemispheres' activity. The second one, the classical lateralization indices method (LIM), was based on calculating lateralization indices by taking into account the number of activated pixels within hemispheres. The main difference between methods is the statistical assessment of the inter-hemispheric difference: while FM shows if the difference between hemispheres' activity is statistically significant, LIM shows only that if there is a difference between hemispheres. The robustness of LIM and FM was assessed by calculating correlation coefficients between LIs obtained with each of these methods and manual lateralization indices MLI obtained with Edinburgh inventory. Our results showed significant correlation between LIs provided by each method and the MIL, suggesting that both methods are robust for quantifying hemispheric dominance for language in healthy subjects. In the present study we also evaluated the effect of spatial normalization, smoothing and "clustering" (NSC) on the intra-hemispheric location of activated regions and inter-hemispheric asymmetry of the activation. Our results have shown that NSC did not affect the hemispheric specialization but increased the value of the inter-hemispheric difference.
Same Content, Different Methods: Comparing Lecture, Engaged Classroom, and Simulation.
Raleigh, Meghan F; Wilson, Garland Anthony; Moss, David Alan; Reineke-Piper, Kristen A; Walden, Jeffrey; Fisher, Daniel J; Williams, Tracy; Alexander, Christienne; Niceler, Brock; Viera, Anthony J; Zakrajsek, Todd
2018-02-01
There is a push to use classroom technology and active teaching methods to replace didactic lectures as the most prevalent format for resident education. This multisite collaborative cohort study involving nine residency programs across the United States compared a standard slide-based didactic lecture, a facilitated group discussion via an engaged classroom, and a high-fidelity, hands-on simulation scenario for teaching the topic of acute dyspnea. The primary outcome was knowledge retention at 2 to 4 weeks. Each teaching method was assigned to three different residency programs in the collaborative according to local resources. Learning objectives were determined by faculty. Pre- and posttest questions were validated and utilized as a measurement of knowledge retention. Each site administered the pretest, taught the topic of acute dyspnea utilizing their assigned method, and administered a posttest 2 to 4 weeks later. Differences between the groups were compared using paired t-tests. A total of 146 residents completed the posttest, and scores increased from baseline across all groups. The average score increased 6% in the standard lecture group (n=47), 11% in the engaged classroom (n=53), and 9% in the simulation group (n=56). The differences in improvement between engaged classroom and simulation were not statistically significant. Compared to standard lecture, both engaged classroom and high-fidelity simulation were associated with a statistically significant improvement in knowledge retention. Knowledge retention after engaged classroom and high-fidelity simulation did not significantly differ. More research is necessary to determine if different teaching methods result in different levels of comfort and skill with actual patient care.
Does the Classroom Delivery Method Make a Difference?
ERIC Educational Resources Information Center
Bunn, Esther; Fischer, Mary; Marsh, Treba
2014-01-01
This study seeks to determine if a difference exists in student performance and participation between an online and face-to-face Accounting Intermediate I class taught by the same professor. Even though students self-selected which course section to enroll, no significant difference was found to exist between the delivery method of the two courses…
The oxygen uptake slow component at submaximal intensities in breaststroke swimming
Oliveira, Diogo R.; Gonçalves, Lio F.; Reis, António M.; Fernandes, Ricardo J.; Garrido, Nuno D.
2016-01-01
Abstract The present work proposed to study the oxygen uptake slow component (VO2 SC) of breaststroke swimmers at four different intensities of submaximal exercise, via mathematical modeling of a multi-exponential function. The slow component (SC) was also assessed with two different fixed interval methods and the three methods were compared. Twelve male swimmers performed a test comprising four submaximal 300 m bouts at different intensities where all expired gases were collected breath by breath. Multi-exponential modeling showed values above 450 ml·min−1 of the SC in the two last bouts of exercise (those with intensities above the lactate threshold). A significant effect of the method that was used to calculate the VO2 SC was revealed. Higher mean values were observed when using mathematical modeling compared with the fixed interval 3rd min method (F=7.111; p=0.012; η2=0.587); furthermore, differences were detected among the two fixed interval methods. No significant relationship was found between the SC determined by any method and the blood lactate measured at each of the four exercise intensities. In addition, no significant association between the SC and peak oxygen uptake was found. It was concluded that in trained breaststroke swimmers, the presence of the VO2 SC may be observed at intensities above that corresponding to the 3.5 mM-1 threshold. Moreover, mathematical modeling of the oxygen uptake on-kinetics tended to show a higher slow component as compared to fixed interval methods. PMID:28149379
Agbangla, N F; Audiffren, M; Albinet, C T
2017-12-20
Using continuous-wave near-infrared spectroscopy (NIRS), this study compared three different methods, namely the slope method (SM), the amplitude method (AM), and the area under the curve (AUC) method to determine the variations of intramuscular oxygenation level as a function of workload. Ten right-handed subjects (22+/-4 years) performed one isometric contraction at each of three different workloads (30 %, 50 % and 90 % of maximal voluntary strength) during a period of twenty seconds. Changes in oxyhemoglobin (delta[HbO(2)]) and deoxyhemoglobin (delta[HHb]) concentrations in the superficial flexor of fingers were recorded using continuous-wave NIRS. The results showed a strong consistency between the three methods, with standardized Cronbach alphas of 0.87 for delta[HHb] and 0.95 for delta[HbO(2)]. No significant differences between the three methods were observed concerning delta[HHb] as a function of workload. However, only the SM showed sufficient sensitivity to detect a significant decrease in delta[HbO(2)] between 30 % and 50 % of workload (p<0.01). Among these three methods, the SM appeared to be the only method that was well adapted and sensitive enough to determine slight changes in delta[HbO(2)]. Theoretical and methodological implications of these results are discussed.
Jabari, Hamidreza; Sami, Ramin; Fakhri, Mohammad; Kiani, Arda
2012-01-01
Forceps biopsy is the standard procedure to obtain specimens in endobronchial lesions. New studies have proposed flexible cryoprobe as an accepted alternative method for this technique. Although diagnostic use of the cryobiopsy is confirmed in few studies, there is paucity of data with regard to an optimum protocol for this method since one of the main considerations in cryobiopsy is the freezing time. To evaluate diagnostic yield and safety of endobronchial biopsies using the flexible cryoprobe. Moreover, different freezing times were assessed to propose an optimized protocol for this diagnostic modality. For each patient with a confirmed intrabronchial lesion, diagnostic o value of forceps biopsy, cryobiopsy in three seconds, cryobiopsy in five seconds and combined results of cryobiopsy in both timings were recorded. A total of 60 patients (39 males and 21 females; Mean age 56.7 +/- 13.3) were included. Specimens that were obtained by cryobiopsy in five seconds were significantly larger than those of forceps biopsy and cryobiopsy in three seconds (p < 0.001). We showed that the achieved diagnostic yields for all three methods were not statistically different (p > 0.05). Simultaneous usage of samples produced in both cryobiopsies can significantly improve the diagnostic yield (p = 0.02). Statistical analysis showed that there were no significant differences in case of bleeding frequency among the three sampling methods. This study confirmed safety and feasibility of cryobiopsy. Additionally, combination of sampling with two different cold induction timings would significantly increase sensitivity of this emerging technique..
Comparison of the effect of three autogenous bone harvesting methods on cell viability in rabbits
Moradi Haghgoo, Janet; Arabi, Seyed Reza; Hosseinipanah, Seyyed Mohammad; Solgi, Ghasem; Rastegarfard, Neda; Farhadian, Maryam
2017-01-01
Background. This study was designed to compare the viability of autogenous bone grafts, harvested using different methods, in order to determine the best harvesting technique with respect to more viable cells. Methods. In this animal experimental study, three harvesting methods, including manual instrument (chisel), rotary device and piezosurgery, were used for harvesting bone grafts from the lateral body of the mandible on the left and right sides of 10 rabbits. In each group, 20 bone samples were collected and their viability was assessed using MTS kit. Statistical analyses, including ANOVA and post hoc Tukey tests, were used for evaluating significant differences between the groups. Results. One-way ANOVA showed significant differences between all the groups (P=0.000). Data analysis using post hoc Tukey tests indicated that manual instrument and piezosurgery had no significant differences with regard to cell viability (P=0.749) and the cell viability in both groups was higher than that with the use of a rotary instrument (P=0.000). Conclusion. Autogenous bone grafts harvested with a manual instrument and piezosurgery had more viable cells in comparison to the bone chips harvested with a rotary device. PMID:28748046
Qiu, Ling; Guo, Xiuzhi; Zhu, Yan; Shou, Weilin; Gong, Mengchun; Zhang, Lin; Han, Huijuan; Quan, Guoqiang; Xu, Tao; Li, Hang; Li, Xuewang
2013-01-01
To investigate the impact of serum creatinine measurement on the applicability of glomerular filtration rate (GFR) evaluation equations. 99mTc-DTPA plasma clearance rate was used as GFR reference (rGFR) in patients with chronic kidney disease (CKD). Serum creatinine was measureded using enzymatic or picric acid creatinine reagent. The GFR of the patients were estimated using the Cockcroft-Gault equation corrected for body surface area, simplified Modification of Diet in Renal Disease (MDRD) equation, simplified MDRD equation corrected to isotopes dilution mass spectrometry, the CKD epidemiology collaborative research equation, and two Chinese simplified MDRD equations. Significant differences in the eGFR results estimated through enzymatic and picric acid methods were observed for the same evaluation equation. The intraclass correlation coefficient (ICC) of eGFR when the creatinine was measured by the picric acid method was significantly lower than that of the enzymatic method. The assessment accuracy of every equation using the enzymatic method to measure creatinine was significantly higher than that measured by the picric acid method when rGFR was > or = 60 mL/min/1.73m2. A significant difference was demonstrated in the same GFR evaluation equation using the picric acid and enzymatic methods. The enzymatic creatinine method was better than the picric acid method.
Testing an automated method to estimate ground-water recharge from streamflow records
Rutledge, A.T.; Daniel, C.C.
1994-01-01
The computer program, RORA, allows automated analysis of streamflow hydrographs to estimate ground-water recharge. Output from the program, which is based on the recession-curve-displacement method (often referred to as the Rorabaugh method, for whom the program is named), was compared to estimates of recharge obtained from a manual analysis of 156 years of streamflow record from 15 streamflow-gaging stations in the eastern United States. Statistical tests showed that there was no significant difference between paired estimates of annual recharge by the two methods. Tests of results produced by the four workers who performed the manual method showed that results can differ significantly between workers. Twenty-two percent of the variation between manual and automated estimates could be attributed to having different workers perform the manual method. The program RORA will produce estimates of recharge equivalent to estimates produced manually, greatly increase the speed od analysis, and reduce the subjectivity inherent in manual analysis.
Wang, Junqiang; Wang, Yu; Zhu, Gang; Chen, Xiangqian; Zhao, Xiangrui; Qiao, Huiting; Fan, Yubo
2018-06-01
Spatial positioning accuracy is a key issue in a computer-assisted orthopaedic surgery (CAOS) system. Since intraoperative fluoroscopic images are one of the most important input data to the CAOS system, the quality of these images should have a significant influence on the accuracy of the CAOS system. But the regularities and mechanism of the influence of the quality of intraoperative images on the accuracy of a CAOS system have yet to be studied. Two typical spatial positioning methods - a C-arm calibration-based method and a bi-planar positioning method - are used to study the influence of different image quality parameters, such as resolution, distortion, contrast and signal-to-noise ratio, on positioning accuracy. The error propagation rules of image error in different spatial positioning methods are analyzed by the Monte Carlo method. Correlation analysis showed that resolution and distortion had a significant influence on spatial positioning accuracy. In addition the C-arm calibration-based method was more sensitive to image distortion, while the bi-planar positioning method was more susceptible to image resolution. The image contrast and signal-to-noise ratio have no significant influence on the spatial positioning accuracy. The result of Monte Carlo analysis proved that generally the bi-planar positioning method was more sensitive to image quality than the C-arm calibration-based method. The quality of intraoperative fluoroscopic images is a key issue in the spatial positioning accuracy of a CAOS system. Although the 2 typical positioning methods have very similar mathematical principles, they showed different sensitivities to different image quality parameters. The result of this research may help to create a realistic standard for intraoperative fluoroscopic images for CAOS systems. Copyright © 2018 John Wiley & Sons, Ltd.
Luebker, Stephen A; Wojtkiewicz, Melinda; Koepsell, Scott A
2015-11-01
Formalin-fixed paraffin-embedded (FFPE) tissue is a rich source of clinically relevant material that can yield important translational biomarker discovery using proteomic analysis. Protocols for analyzing FFPE tissue by LC-MS/MS exist, but standardization of procedures and critical analysis of data quality is limited. This study compared and characterized data obtained from FFPE tissue using two methods: a urea in-solution digestion method (UISD) versus a commercially available Qproteome FFPE Tissue Kit method (Qkit). Each method was performed independently three times on serial sections of homogenous FFPE tissue to minimize pre-analytical variations and analyzed with three technical replicates by LC-MS/MS. Data were evaluated for reproducibility and physiochemical distribution, which highlighted differences in the ability of each method to identify proteins of different molecular weights and isoelectric points. Each method replicate resulted in a significant number of new protein identifications, and both methods identified significantly more proteins using three technical replicates as compared to only two. UISD was cheaper, required less time, and introduced significant protein modifications as compared to the Qkit method, which provided more precise and higher protein yields. These data highlight significant variability among method replicates and type of method used, despite minimizing pre-analytical variability. Utilization of only one method or too few replicates (both method and technical) may limit the subset of proteomic information obtained. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Zhang, Anping; Luo, Wenxiu; Sun, Jianqiang; Xiao, Hang; Liu, Weiping
2015-02-01
The application of greenhouse vegetable cultivation has dramatically expanded worldwide during the last several decades. However, little information is available on the distribution and uptake of pesticides in greenhouse vegetables. To bridge this knowledge gap, the present study was initiated to investigate the distribution and uptake of organochlorine pesticides (OCPs) in vegetables from plastic greenhouse and conventional cultivation methods. The uptake pathways of OCPs were not significantly different between these two cultivation methods. The arithmetic means of OCP concentrations in greenhouse vegetables were higher than those in conventional vegetables, although there was no significant difference. This small difference raised the concern of whether the tiny difference could be magnified to a significant difference by bioaccumulation in the food chain. The issue should be addressed by a well-designed scheme in future studies. Copyright © 2014 Elsevier B.V. All rights reserved.
Shahgholian, Nahid; Jazi, Shahrzad Khojandi; Karimian, Jahangir; Valiani, Mahboubeh
2016-01-01
Background: Restless leg syndrome prevalence is high among the patients undergoing hemodialysis. Due to several side effects of medicational treatments, the patients prefer non-medicational methods. Therefore, the present study aimed to investigate the effects of two methods of reflexology and stretching exercises on the severity of restless leg syndrome among patients undergoing hemodialysis. Materials and Methods: This study is a randomized clinical trial that was done on 90 qualified patients undergoing hemodialysis in selected hospitals of Isfahan, who were diagnosed with restless leg syndrome through standard restless leg syndrome questionnaire. They were randomly assigned by random number table to three groups: Reflexology, stretching exercises, and control groups through random allocation. Foot reflexology and stretching exercises were conducted three times a week for 30–40 min within straight 4 weeks. Data analysis was performed by SPSS version 18 using descriptive and inferential statistical analyses [one-way analysis of variance (ANOVA), paired t-test, and least significant difference (LSD) post hoc test]. Results: There was a significant difference in the mean scores of restless leg syndrome severity between reflexology and stretching exercises groups, compared to control (P < 0.001), but there was no significant difference between the two study groups (P < 0.001). Changes in the mean score of restless leg syndrome severity were significantly higher in reflexology and stretching exercises groups compared to the control group (P < 0.001), but it showed no significant difference between reflexology massage and stretching exercises groups. Conclusions: Our obtained results showed that reflexology and stretching exercises can reduce the severity of restless leg syndrome. These two methods of treatment are recommended to the patients. PMID:27186197
Yaxley, Anna J; Yaxley, John W; Thangasamy, Isaac A; Ballard, Emma; Pokorny, Morgan R
2017-11-01
To compare the detection rates of prostate cancer (PCa) in men with Prostate Imaging-Reporting and Data System (PI-RADS) 3-5 abnormalities on 3-Tesla multiparametric (mp) magnetic resonance imaging (MRI) using in-bore MRI-guided biopsy compared with cognitively directed transperineal (cTP) biopsy and transrectal ultrasonography (cTRUS) biopsy. This was a retrospective single-centre study of consecutive men attending the private practice clinic of an experienced urologist performing MRI-guided biopsy and an experienced urologist performing cTP and cTRUS biopsy techniques for PI-RADS 3-5 lesions identified on 3-Tesla mpMRI. There were 595 target mpMRI lesions from 482 men with PI-RADS 3-5 regions of interest during 483 episodes of biopsy. The abnormal mpMRI target lesion was biopsied using the MRI-guided method for 298 biopsies, the cTP method for 248 biopsies and the cTRUS method for 49 biopsies. There were no significant differences in PCa detection among the three biopsy methods in PI-RADS 3 (48.9%, 40.0% and 44.4%, respectively), PI-RADS 4 (73.2%, 81.0% and 85.0%, respectively) or PI-RADS 5 (95.2, 92.0% and 95.0%, respectively) lesions, and there was no significant difference in detection of significant PCa among the biopsy methods in PI-RADS 3 (42.2%, 30.0% and 33.3%, respectively), PI-RADS 4 (66.8%, 66.0% and 80.0%, respectively) or PI-RADS 5 (90.5%, 89.8% and 90.0%, respectively) lesions. There were also no differences in PCa or significant PCa detection based on lesion location or size among the methods. We found no significant difference in the ability to detect PCa or significant PCa using targeted MRI-guided, cTP or cTRUS biopsy methods. Identification of an abnormal area on mpMRI appears to be more important in increasing the detection of PCa than the technique used to biopsy an MRI abnormality. © 2017 The Authors BJU International © 2017 BJU International Published by John Wiley & Sons Ltd.
Subjective evaluation of compressed image quality
NASA Astrophysics Data System (ADS)
Lee, Heesub; Rowberg, Alan H.; Frank, Mark S.; Choi, Hyung-Sik; Kim, Yongmin
1992-05-01
Lossy data compression generates distortion or error on the reconstructed image and the distortion becomes visible as the compression ratio increases. Even at the same compression ratio, the distortion appears differently depending on the compression method used. Because of the nonlinearity of the human visual system and lossy data compression methods, we have evaluated subjectively the quality of medical images compressed with two different methods, an intraframe and interframe coding algorithms. The evaluated raw data were analyzed statistically to measure interrater reliability and reliability of an individual reader. Also, the analysis of variance was used to identify which compression method is better statistically, and from what compression ratio the quality of a compressed image is evaluated as poorer than that of the original. Nine x-ray CT head images from three patients were used as test cases. Six radiologists participated in reading the 99 images (some were duplicates) compressed at four different compression ratios, original, 5:1, 10:1, and 15:1. The six readers agree more than by chance alone and their agreement was statistically significant, but there were large variations among readers as well as within a reader. The displacement estimated interframe coding algorithm is significantly better in quality than that of the 2-D block DCT at significance level 0.05. Also, 10:1 compressed images with the interframe coding algorithm do not show any significant differences from the original at level 0.05.
Effect of Resin-modified Glass Ionomer Cement Dispensing/Mixing Methods on Mechanical Properties.
Sulaiman, T A; Abdulmajeed, A A; Altitinchi, A; Ahmed, S N; Donovan, T E
2018-03-23
Resin-modified glass ionomer cements (RMGIs) are often used for luting indirect restorations. Hand-mixing traditional cements demands significant time and may be technique sensitive. Efforts have been made by manufacturers to introduce the same cement using different dispensing/mixing methods. It is not known what effects these changes may have on the mechanical properties of the dental cement. The purpose of this study was to evaluate the mechanical properties (diametral tensile strength [DTS], compressive strength [CS], and fracture toughness [FT]) of RMGIs with different dispensing/mixing systems. The RMGI specimens (n=14)-RelyX Luting (hand mix), RelyX Luting Plus (clicker-hand mix), RelyX Luting Plus (automix) (3M ESPE), GC Fuji PLUS (capsule-automix), and GC FujiCEM 2 (automix) (GC)-were prepared for each mechanical test and examined after thermocycling (n=7/subgroup) for 20,000 cycles to the following: DTS, CS (ISO 9917-1) and FT (ISO standard 6872; Single-edge V-notched beam method). Specimens were mounted and loaded with a universal testing machine until failure occurred. Two-/one-way analysis of variance followed by Tukey honestly significantly different post hoc test was used to analyze data for statistical significance ( p<0.05). The interaction effect of both dispensing/mixing method and thermocycling was significant only for the CS test of the GC group ( p<0.05). The different dispensing/mixing methods had no effect on the DTS of the tested cements. The CS of GC Fuji PLUS was significantly higher than that of the automix version ( p<0.05). The FT decreased significantly when switching from RelyX (hand mix) to RelyX Luting Plus (clicker-hand mix) and to RelyX Luting Plus (automix) ( p<0.05). Except in the case of the DTS of the GC group and the CS of GC Fuji PLUS, thermocycling had a significant effect reducing the mechanical properties of the RMGI cements ( p<0.05). Introducing alternative dispensing/mixing methods for mixing RMGIs to reduce time and technique sensitivity may affect mechanical properties and is brand dependent.
Mori, V; Oliveira, M A; Vargas, M H M; da Cunha, A A; de Souza, R G; Pitrez, P M; Moriya, H T
2017-06-01
Objective and approach: In this study, we estimated the constant phase model (CPM) parameters from the respiratory impedance of male BALB/c mice by performing the forced oscillation technique (FOT) in a control group (n = 8) and in a murine model of asthma (OVA) (n = 10). Then, we compared the results obtained by two different methods, using a commercial equipment (flexiVent-flexiWare 7.X; SCIREQ, Montreal, Canada) (FXV) and a wavetube method equipment (Sly et al 2003 J. Appl. Physiol. 94 1460-6) (WVT). We believe that the results from different methods may not be comparable. First, we compared the results performing a two-way analysis of variance (ANOVA) for the resistance, elastance and tissue damping. We found statistically significant differences in all CPM parameters, except for resistance, when comparing Control and OVA groups. When comparing devices, we found statistically significant differences in resistance, while differences in elastance were not observed. For tissue damping, the results from WVT were observed to be higher than those from FXV. Finally, when comparing the relative variation between the CPM parameters of the Control and OVA groups in both devices, no significant differences were observed for all parameters. We then conclude that this assessment can compensate the effect of using different cannulas. Furthermore, tissue damping differences between groups can be compensated, since bronchoconstrictors were not used. Therefore, we believe that relative variations in the results between groups can be a comparing parameter when using different equipment without bronchoconstrictor administration.
Evaluation of Eight Methods for Aligning Orientation of Two Coordinate Systems.
Mecheri, Hakim; Robert-Lachaine, Xavier; Larue, Christian; Plamondon, André
2016-08-01
The aim of this study was to evaluate eight methods for aligning the orientation of two different local coordinate systems. Alignment is very important when combining two different systems of motion analysis. Two of the methods were developed specifically for biomechanical studies, and because there have been at least three decades of algorithm development in robotics, it was decided to include six methods from this field. To compare these methods, an Xsens sensor and two Optotrak clusters were attached to a Plexiglas plate. The first optical marker cluster was fixed on the sensor and 20 trials were recorded. The error of alignment was calculated for each trial, and the mean, the standard deviation, and the maximum values of this error over all trials were reported. One-way repeated measures analysis of variance revealed that the alignment error differed significantly across the eight methods. Post-hoc tests showed that the alignment error from the methods based on angular velocities was significantly lower than for the other methods. The method using angular velocities performed the best, with an average error of 0.17 ± 0.08 deg. We therefore recommend this method, which is easy to perform and provides accurate alignment.
Tan, Fa-Bing; Wang, Lu; Fu, Gang; Wu, Shu-Hong; Jin, Ping
2010-02-01
To study the effect of different optical impression methods in Cerec 3D/Inlab MC XL system on marginal and internal fit of all-ceramic crowns. A right mandibular first molar in the standard model was used to prepare full crown and replicated into thirty-two plaster casts. Sixteen of them were selected randomly for bonding crown and the others were used for taking optical impression, in half of which the direct optical impression taking method were used and the others were used for the indirect method, and then eight Cerec Blocs all-ceramic crowns were manufactured respectively. The fit of all-ceramic crowns were evaluated by modified United States Public Health Service (USPHS) criteria and scanning electron microscope (SEM) imaging, and the data were statistically analyzed with SAS 9.1 software. The clinically acceptable rate for all marginal measurement sites was 87.5% according to USPHS criteria. There was no statistically significant difference in marginal fit between direct and indirect method group (P > 0.05). With SEM imaging, all marginal measurement sites were less than 120 microm and no statistically significant difference was found between direct and indirect method group in terms of marginal or internal fit (P > 0.05). But the direct method group showed better fit than indirect method group in terms of mesial surface, lingual surface, buccal surface and occlusal surface (P < 0.05). The distal surface's fit was worse and the obvious difference was observed between mesial surface and distal surface in direct method group (P < 0.01). Under the conditions of this study, the optical impression method had no significant effect on marginal fit of Cerec Blocs crowns, but it had certain effect on internal fit. Overall all-ceramic crowns appeared to have clinically acceptable marginal fit.
Evaluation of user input methods for manipulating a tablet personal computer in sterile techniques.
Yamada, Akira; Komatsu, Daisuke; Suzuki, Takeshi; Kurozumi, Masahiro; Fujinaga, Yasunari; Ueda, Kazuhiko; Kadoya, Masumi
2017-02-01
To determine a quick and accurate user input method for manipulating tablet personal computers (PCs) in sterile techniques. We evaluated three different manipulation methods, (1) Computer mouse and sterile system drape, (2) Fingers and sterile system drape, and (3) Digitizer stylus and sterile ultrasound probe cover with a pinhole, in terms of the central processing unit (CPU) performance, manipulation performance, and contactlessness. A significant decrease in CPU score ([Formula: see text]) and an increase in CPU temperature ([Formula: see text]) were observed when a system drape was used. The respective mean times taken to select a target image from an image series (ST) and the mean times for measuring points on an image (MT) were [Formula: see text] and [Formula: see text] s for the computer mouse method, [Formula: see text] and [Formula: see text] s for the finger method, and [Formula: see text] and [Formula: see text] s for the digitizer stylus method, respectively. The ST for the finger method was significantly longer than for the digitizer stylus method ([Formula: see text]). The MT for the computer mouse method was significantly longer than for the digitizer stylus method ([Formula: see text]). The mean success rate for measuring points on an image was significantly lower for the finger method when the diameter of the target was equal to or smaller than 8 mm than for the other methods. No significant difference in the adenosine triphosphate amount at the surface of the tablet PC was observed before, during, or after manipulation via the digitizer stylus method while wearing starch-powdered sterile gloves ([Formula: see text]). Quick and accurate manipulation of tablet PCs in sterile techniques without CPU load is feasible using a digitizer stylus and sterile ultrasound probe cover with a pinhole.
NASA Astrophysics Data System (ADS)
Ranaie, Mehrdad; Soffianian, Alireza; Pourmanafi, Saeid; Mirghaffari, Noorollah; Tarkesh, Mostafa
2018-03-01
In recent decade, analyzing the remotely sensed imagery is considered as one of the most common and widely used procedures in the environmental studies. In this case, supervised image classification techniques play a central role. Hence, taking a high resolution Worldview-3 over a mixed urbanized landscape in Iran, three less applied image classification methods including Bagged CART, Stochastic gradient boosting model and Neural network with feature extraction were tested and compared with two prevalent methods: random forest and support vector machine with linear kernel. To do so, each method was run ten time and three validation techniques was used to estimate the accuracy statistics consist of cross validation, independent validation and validation with total of train data. Moreover, using ANOVA and Tukey test, statistical difference significance between the classification methods was significantly surveyed. In general, the results showed that random forest with marginal difference compared to Bagged CART and stochastic gradient boosting model is the best performing method whilst based on independent validation there was no significant difference between the performances of classification methods. It should be finally noted that neural network with feature extraction and linear support vector machine had better processing speed than other.
NASA Astrophysics Data System (ADS)
Shi, Xiaoyu; Shang, Ming-Sheng; Luo, Xin; Khushnood, Abbas; Li, Jian
2017-02-01
As the explosion growth of Internet economy, recommender system has become an important technology to solve the problem of information overload. However, recommenders are not one-size-fits-all, different recommenders have different virtues, making them be suitable for different users. In this paper, we propose a novel personalized recommender based on user preferences, which allows multiple recommenders to exist in E-commerce system simultaneously. We find that output of a recommender to each user is quite different when using different recommenders, the recommendation accuracy can be significantly improved if each user is assigned with his/her optimal personalized recommender. Furthermore, different from previous works focusing on short-term effects on recommender, we also evaluate the long-term effect of the proposed method by modeling the evolution of mutual feedback between user and online system. Finally, compared with single recommender running on the online system, the proposed method can improve the accuracy of recommendation significantly and get better trade-offs between short- and long-term performances of recommendation.
Melching, C.S.; Coupe, R.H.
1995-01-01
During water years 1985-91, the U.S. Geological Survey (USGS) and the Illinois Environmental Protection Agency (IEPA) cooperated in the collection and analysis of concurrent and split stream-water samples from selected sites in Illinois. Concurrent samples were collected independently by field personnel from each agency at the same time and sent to the IEPA laboratory, whereas the split samples were collected by USGS field personnel and divided into aliquots that were sent to each agency's laboratory for analysis. The water-quality data from these programs were examined by means of the Wilcoxon signed ranks test to identify statistically significant differences between results of the USGS and IEPA analyses. The data sets for constituents and properties identified by the Wilcoxon test as having significant differences were further examined by use of the paired t-test, mean relative percentage difference, and scattergrams to determine if the differences were important. Of the 63 constituents and properties in the concurrent-sample analysis, differences in only 2 (pH and ammonia) were statistically significant and large enough to concern water-quality engineers and planners. Of the 27 constituents and properties in the split-sample analysis, differences in 9 (turbidity, dissolved potassium, ammonia, total phosphorus, dissolved aluminum, dissolved barium, dissolved iron, dissolved manganese, and dissolved nickel) were statistically significant and large enough to con- cern water-quality engineers and planners. The differences in concentration between pairs of the concurrent samples were compared to the precision of the laboratory or field method used. The differences in concentration between pairs of the concurrent samples were compared to the precision of the laboratory or field method used. The differences in concentration between paris of split samples were compared to the precision of the laboratory method used and the interlaboratory precision of measuring a given concentration or property. Consideration of method precision indicated that differences between concurrent samples were insignificant for all concentrations and properties except pH, and that differences between split samples were significant for all concentrations and properties. Consideration of interlaboratory precision indicated that the differences between the split samples were not unusually large. The results for the split samples illustrate the difficulty in obtaining comparable and accurate water-quality data.
Brandt, William Cunha; Silva-Concilio, Lais Regiane; Neves, Ana Christina Claro; de Souza-Junior, Eduardo Jose Carvalho; Sinhoreti, Mario Alexandre Coelho
2013-09-01
The aim of this study was to evaluate in vitro the Knoop hardness in the top and bottom of composite photo activated by different methods when different mold materials were used. Z250 (3M ESPE) and XL2500 halogen unit (3M ESPE) were used. For hardness test, conical restorations were made in extracted bovine incisors (tooth mold) and also metal mold (approximately 2 mm top diameter × 1.5 mm bottom diameter × 2 mm in height). Different photoactivation methods were tested: high-intensity continuous (HIC), low-intensity continuous (LIC), soft-start, or pulse-delay (PD), with constant radiant exposure. Knoop readings were performed on top and bottom restoration surfaces. Data were submitted to two-way ANOVA and Tukey's test (p = 0.05). On the top, regardless of the mold used, no significant difference in the Knoop hardness (Knoop hardness number, in kilograms-force per square millimeter) was observed between the photoactivation methods. On the bottom surface, the photoactivation method HIC shows higher means of hardness than LIC when tooth and metal were used. Significant differences of hardness on the top and in the bottom were detected between tooth and metal. The photoactivation method LIC and the material mold can interfere in the hardness values of composite restorations.
Physiological and subjective responses to standing showers, sitting showers, and sink baths.
Ohnaka, T; Tochihara, Y; Kubo, M; Yamaguchi, C
1995-09-01
The purpose of this study was to investigate physiological and subjective responses during and after bathing in three different bathing methods. Eight healthy males bathed for 10 minutes, and then rested for 30 minutes. Three kinds of bathing methods - standing shower, sitting shower and sink bath - were adopted in this experiment. Water temperature and flow volume of the showers were kept at 41 degrees C and 11 liter/min, while water temperature of the bath was kept at 40 degrees C. Rectal temperature, skin temperatures and heart rate of the subjects were measured continuously during bathing and the subsequent 30-minute rest. Blood pressure and votes for thermal sensations were recorded before bathing, after 5 and 10 minutes of bathing, and 5, 10, 20 and 30 minutes after bathing. The following results were obtained. 1) Although rectal temperature rose, on the average, by 0.15 degrees C in all bathing methods, there were no significant differences among the three bathing methods at any time in the experiment. 2) Mean skin temperature (Tsk) during the sink bath was significantly higher than that in the standing or sitting shower. After bathing, Tsk of sink bath was slightly higher than those of the remaining conditions, but did not significantly differ among the bathing methods. 3) Heart rate increased gradually during all the bathing methods, however, only HR in the standing shower exceeded 100 beats/min which was significantly higher than those of the two remaining bathing methods. 4) Blood pressure (BP) decreased rapidly during the sink bath in contrast to an increased BP in the sitting and standing showers.
Mohamadirizi, Soheila; Fahami, Fariba; Bahadoran, Parvin; Ehsanpour, Soheila
2015-01-01
Background: An active teaching method has been used widely in medical education. The aim of this study was to determine the effectiveness of the four-phase teaching method on midwifery students’ emotional intelligence (EQ) in managing the childbirth. Materials and Methods: This was an experimental study that performed in 2013 in Isfahan University of Medical Sciences. Thirty midwifery students were involved in this study and selected through a random sampling method. The EQ questionnaire (43Q) was completed by both the groups, before and after the education. The collected data were analyzed using SPSS 14, the independent t-test, and the paired t-test. The statistically significant level was considered to be <0.05. Results: The findings of the independent t-test did not show any significant difference between EQ scores of the experimental and the control group before the intervention, whereas a statistically significant difference was observed after the intervention between the scores of two groups (P = 0.009). The paired t-test showed a statistically significant difference in EQ scores in the two groups after the intervention in the four-phase and the control group, respectively, as P = 0.005 and P = 0.018. Furthermore, the rate of self-efficiency has increased in the experimental group and control group as 66% and 13% (P = 0.024), respectively. Conclusion: The four-phase teaching method can increase the EQ levels of midwifery students. Therefore, the conduction of this educational model is recommended as an effective learning method. PMID:26097861
Bier, Nathalie; Van Der Linden, Martial; Gagnon, Lise; Desrosiers, Johanne; Adam, Stephane; Louveaux, Stephanie; Saint-Mleux, Julie
2008-06-01
This study compared the efficacy of five learning methods in the acquisition of face-name associations in early dementia of Alzheimer type (AD). The contribution of error production and implicit memory to the efficacy of each method was also examined. Fifteen participants with early AD and 15 matched controls were exposed to five learning methods: spaced retrieval, vanishing cues, errorless, and two trial-and-error methods, one with explicit and one with implicit memory task instructions. Under each method, participants had to learn a list of five face-name associations, followed by free recall, cued recall and recognition. Delayed recall was also assessed. For AD, results showed that all methods were efficient but there were no significant differences between them. The number of errors produced during the learning phases varied between the five methods but did not influence learning. There were no significant differences between implicit and explicit memory task instructions on test performances. For the control group, there were no differences between the five methods. Finally, no significant correlations were found between the performance of the AD participants in free recall and their cognitive profile, but generally, the best performers had better remaining episodic memory. Also, case study analyses showed that spaced retrieval was the method for which the greatest number of participants (four) obtained results as good as the controls. This study suggests that the five methods are effective for new learning of face-name associations in AD. It appears that early AD patients can learn, even in the context of error production and explicit memory conditions.
Sajadi, Mahboobeh; Fayazi, Neda; Fournier, Andrew; Abedi, Ahmad Reza
2017-01-01
Background: The most important responsibilities of an education system are to create self-directed learning opportunities and develop the required skills for taking the responsibility for change. The present study aimed at determining the impact of a learning contract on self-directed learning and satisfaction of nursing students. Methods: A total of 59 nursing students participated in this experimental study. They were divided into six 10-member groups. To control the communications among the groups, the first 3 groups were trained using conventional learning methods and the second 3 groups using learning contract method. In the first session, a pretest was performed based on educational objectives. At the end of the training, the students in each group completed the questionnaires of self-directed learning and satisfaction. The results of descriptive and inferential statistical methods (dependent and independent t tests) were presented using SPSS. Results: There were no significant differences between the 2 groups in gender, grade point average of previous years, and interest toward nursing. However, the results revealed a significant difference between the 2 groups in the total score of self-directed learning (p= 0.019). Although the mean satisfaction score was higher in the intervention group, the difference was not statistically significant. Conclusion: This study suggested that the use of learning contract method in clinical settings enhances self-directed learning among nursing students. Because this model focuses on individual differences, the researcher highly recommends the application of this new method to educators.
Wu, Hai-miao; Zhao, Bin-jiao; Chen, Dong
2015-06-01
To compare the shear bond strength (SBS) of rebonded orthodontic metal brackets with different resin removal methods. Forty extracted premolars were chosen as samples and divided into 4 experimental groups. The teeth were bonded with brackets. The brackets from 3 groups were debonded while adhesive remnants were removed from bracket bases by methods of grinding, sandblasting, and direct flaming, respectively and then rebonded. The SBS values of all rebonded brackets were determined after pH cycling experiment for 30 days. Some rebonded bracket bases were selected and observed under scanning electron microscope (SEM). The data was analyzed by one-way ANOVA test using SPSS 13.0 software package. Statistical analysis revealed a significant difference of SBS values among the 4 experimental groups (P<0.05). The SBS values of the group by direct flaming was significantly lower compared to the other groups (P<0.05). There was no significant difference of SBS values among the other groups. The rebonded brackets after resin removal by grinding and sandblasting have a similar SBS compared to the initial brackets adhesive.
A Practical Method for Identifying Significant Change Scores
ERIC Educational Resources Information Center
Cascio, Wayne F.; Kurtines, William M.
1977-01-01
A test of significance for identifying individuals who are most influenced by an experimental treatment as measured by pre-post test change score is presented. The technique requires true difference scores, the reliability of obtained differences, and their standard error of measurement. (Author/JKS)
Mirsadraee, Majid; Shafahie, Ahmad; Reza Khakzad, Mohammad; Sankian, Mojtaba
2014-04-01
Anthracofibrosis is the black discoloration of the bronchial mucosa with deformity and obstruction. Association of this disease with tuberculosis (TB) was approved. The objective of this study was to find the additional benefit of assessment of TB by the polymerase chain reaction (PCR) method. Bronchoscopy was performed on 103 subjects (54 anthracofibrosis and 49 control subjects) who required bronchoscopy for their pulmonary problems. According to bronchoscopic findings, participants were classified to anthracofibrosis and nonanthracotic groups. They were examined for TB with traditional methods such as direct smear (Ziehl-Neelsen staining), Löwenstein-Jensen culture, and histopathology and the new method "PCR" for Mycobacterium tuberculosis genome (IS6110). Age, sex, smoking, and clinical findings were not significantly different in the TB and the non-TB groups. Acid-fast bacilli could be detected by a direct smear in 12 (25%) of the anthracofibrosis subjects, and adding the results of culture and histopathology traditional tests indicated TB in 27 (31%) of the cases. Mycobacterium tuberculosis was diagnosed by PCR in 18 (33%) patients, but the difference was not significant. Detection of acid-fast bacilli in control nonanthracosis subjects was significantly lower (3, 6%), but PCR (20, 40%) and accumulation of results from all traditional methods (22, 44%) showed a nonsignificant difference. The PCR method showed a result equal to traditional methods including accumulation of smear, culture, and histopathology.
Comparison of Manual Refraction Versus Autorefraction in 60 Diabetic Retinopathy Patients
Shirzadi, Keyvan; Shahraki, Kourosh; Yahaghi, Emad; Makateb, Ali; Khosravifard, Keivan
2016-01-01
Aim: The purpose of the study was to evaluate the comparison of manual refraction versus autorefraction in diabetic retinopathy patients. Material and Methods: The study was conducted at the Be’sat Army Hospital from 2013-2015. In the present study differences between two common refractometry methods (manual refractometry and Auto refractometry) in diagnosis and follow up of retinopathy in patients affected with diabetes is investigated. Results: Our results showed that there is a significant difference in visual acuity score of patients between manual and auto refractometry. Despite this fact, spherical equivalent scores of two methods of refractometry did not show a significant statistical difference in the patients. Conclusion: Although use of manual refraction is comparable with autorefraction in evaluating spherical equivalent scores in diabetic patients affected with retinopathy, but in the case of visual acuity results from these two methods are not comparable. PMID:27703289
Effect of different mixing methods on the bacterial microleakage of calcium-enriched mixture cement.
Shahi, Shahriar; Jeddi Khajeh, Soniya; Rahimi, Saeed; Yavari, Hamid R; Jafari, Farnaz; Samiei, Mohammad; Ghasemi, Negin; Milani, Amin S
2016-10-01
Calcium-enriched mixture (CEM) cement is used in the field of endodontics. It is similar to mineral trioxide aggregate in its main ingredients. The present study investigated the effect of different mixing methods on the bacterial microleakage of CEM cement. A total of 55 human single-rooted human permanent teeth were decoronated so that 14-mm-long samples were obtained and obturated with AH26 sealer and gutta-percha using lateral condensation technique. Three millimeters of the root end were cut off and randomly divided into 3 groups of 15 each (3 mixing methods of amalgamator, ultrasonic and conventional) and 2 negative and positive control groups (each containing 5 samples). BHI (brain-heart infusion agar) suspension containing Enterococcus faecalis was used for bacterial leakage assessment. Statistical analysis was carried out using descriptive statistics, Kaplan-Meier survival analysis with censored data and log rank test. Statistical significance was set at P<0.05. The survival means for conventional, amalgamator and ultrasonic methods were 62.13±12.44, 68.87±12.79 and 77.53±12.52 days, respectively. The log rank test showed no significant differences between the groups. Based on the results of the present study it can be concluded that different mixing methods had no significant effect on the bacterial microleakage of CEM cement.
Walicka-Cupryś, Katarzyna; Drzał-Grabiec, Justyna; Mrozkowiak, Mirosław
2013-10-31
BACKGROUND. The photogrammetric method and inclinometer-based measurements are commonly employed to assess the anteroposterior curvatures of the spine. These methods are used both in clinical trials and for screening purposes. The aim of the study was to compare the parameters used to characterise the anteroposterior spinal curvatures as measured by photogrammetry and inclinometry. MATERIAL AND METHODS. The study enrolled 341 subjects: 169 girls and 172 boys, aged 4 to 9 years, from kindergartens and primary schools in Rzeszów. The anteroposterior spinal curvatures were examined by photogrammetry and with a mechanical inclinometer. RESULTS. There were significant differences in the α angle between the inclinometric and photogrammetric assessment in the Student t test (p=0.017) and the Fisher Snedecor test (p=0.0001), with similar differences in the β angle (Student's t p=0.0001, Fisher Snedecor p=0.007). For the γ angle, significant differences were revealed with Student's t test (p=0.0001), but not with the Fisher Snedecor test (p = 0.22). CONCLUSIONS. 1. Measurements of inclination of particular segments of the spine obtained with the photogrammetric method and the inclinometric method in the same study group revealed statistically significant differences. 2. The results of measurements obtained by photogrammetry and inclinometry are not comparable. 3. Further research on agreement between measurements of the anteroposterior spinal curvatures obtained using the available measurement equipment is recommended.
Kim, Seung Hyup
2008-01-01
Objective To evaluate the correlations between prostate volumes estimated by transabdominal, transrectal, and three-dimensional US and the factors affecting the differences. Materials and Methods The prostate volumes of 94 consecutive patients were measured by both transabdominal and transrectal US. Next, the prostate volumes of 58 other patients was measured by both transrectal and three-dimensional US. We evaluated the degree of correlation and mean difference in each comparison. We also analyzed possible factors affecting the differences, such as the experiences of examiners in transrectal US, bladder volume, and prostate volume. Results In the comparison of transabdominal and transrectal US methods, the mean difference was 8.4 ± 10.5 mL and correlation coefficient (r) was 0.775 (p < 0.01). The experienced examiner for the transrectal US method had the highest correlation (r = 0.967) and the significantly smallest difference (5.4 ± 3.9 mL) compared to the other examiners (the beginner and the trained; p < 0.05). Prostate volume measured by transrectal US showed a weak correlation with the difference (r = 0.360, p < 0.05). Bladder volume did not show significant correlation with the difference (r = -0.043, p > 0.05). The comparison between the transrectal and three-dimensional US methods revealed a mean difference of 3.7 ± 3.4 mL and the correlation coefficient was 0.924 for the experienced examiner. Furthermore, no significant difference existed between examiners (p > 0.05). Prostate volume measured by transrectal US showed a positive correlation with the difference for the beginner only (r = 0.405, p < 0.05). Conclusion In the prostate volume estimation by US, experience in transrectal US is important in the correlation with transabdominal US, but not with three-dimensional US. Also, less experienced examiners' assessment of the prostate volume can be affected by prostate volume itself. PMID:18385560
ERIC Educational Resources Information Center
Blanchette, Judith
2012-01-01
The purpose of this empirical study was to determine the extent to which three different objective analytical methods--sequence analysis, surface cohesion analysis, and lexical cohesion analysis--can most accurately identify specific characteristics of online interaction. Statistically significant differences were found in all points of…
The Effects of Three Methods of Observation on Couples in Interactional Research.
ERIC Educational Resources Information Center
Carpenter, Linda J.; Merkel, William T.
1988-01-01
Assessed the effects of three different methods of observation of couples (one-way mirror, audio recording, and video recording) on 30 volunteer, nonclinical married couples. Results suggest that types of observation do not produce significantly different effects on nonclinical couples. (Author/ABL)
NASA Astrophysics Data System (ADS)
Osman, Essam Eldin A.
2018-01-01
This work represents a comparative study of different approaches of manipulating ratio spectra, applied on a binary mixture of ciprofloxacin HCl and dexamethasone sodium phosphate co-formulated as ear drops. The proposed new spectrophotometric methods are: ratio difference spectrophotometric method (RDSM), amplitude center method (ACM), first derivative of the ratio spectra (1DD) and mean centering of ratio spectra (MCR). The proposed methods were checked using laboratory-prepared mixtures and were successfully applied for the analysis of pharmaceutical formulation containing the cited drugs. The proposed methods were validated according to the ICH guidelines. A comparative study was conducted between those methods regarding simplicity, limitations and sensitivity. The obtained results were statistically compared with those obtained from the reported HPLC method, showing no significant difference with respect to accuracy and precision.
Cunningham, Gregory; Freebody, John; Smith, Margaret M; Taha, Mohy E; Young, Allan A; Cass, Benjamin; Giuffre, Bruno
2018-05-16
Most glenoid version measurement methods have been validated on 3-dimensionally corrected axial computed tomography (CT) slices at the mid glenoid. Variability of the vault according to slice height and angulation has not yet been studied and is crucial for proper surgical implant positioning. The aim of this study was to analyze the variation of the glenoid vault compared with the Friedman angle according to different CT slice heights and angulations. The hypothesis was that the Friedman angle would show less variability. Sixty shoulder CT scans were retrieved from a hospital imaging database and were reconstructed in the plane of the scapula. Seven axial slices of different heights and coronal angulations were selected, and measurements were carried out by 3 observers. Mid-glenoid mean version was -8.0° (±4.9°; range, -19.6° to +7.0°) and -2.1° (±4.7°; range, -13.0° to +10.3°) using the vault method and Friedman angle, respectively. For both methods, decreasing slice height or angulation did not significantly alter version. Increasing slice height or angulation significantly increased anteversion for the vault method (P < .001). Both interobserver reliability and intraobserver reliability were significantly higher using the Friedman angle. Version at the mid and lower glenoid is similar using either method. The vault method shows less reliability and more variability according to slice height or angulation. Yet, as it significantly differs from the Friedman angle, it should still be used in situations where maximum bone purchase is sought with glenoid implants. For any other situation, the Friedman angle remains the method of choice. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
RapidRIP quantifies the intracellular metabolome of 7 industrial strains of E. coli.
McCloskey, Douglas; Xu, Julia; Schrübbers, Lars; Christensen, Hanne B; Herrgård, Markus J
2018-04-25
Fast metabolite quantification methods are required for high throughput screening of microbial strains obtained by combinatorial or evolutionary engineering approaches. In this study, a rapid RIP-LC-MS/MS (RapidRIP) method for high-throughput quantitative metabolomics was developed and validated that was capable of quantifying 102 metabolites from central, amino acid, energy, nucleotide, and cofactor metabolism in less than 5 minutes. The method was shown to have comparable sensitivity and resolving capability as compared to a full length RIP-LC-MS/MS method (FullRIP). The RapidRIP method was used to quantify the metabolome of seven industrial strains of E. coli revealing significant differences in glycolytic, pentose phosphate, TCA cycle, amino acid, and energy and cofactor metabolites were found. These differences translated to statistically and biologically significant differences in thermodynamics of biochemical reactions between strains that could have implications when choosing a host for bioprocessing. Copyright © 2018. Published by Elsevier Inc.
Lettau, Michael; Kotter, Elmar; Bendszus, Martin; Hähnel, Stefan
2014-10-01
CT angiography (CTA) is an increasingly used method for evaluation of stented vessel segments. Our aim was to compare the appearance of different carotid artery stents in vitro on CTA using different CT scanners. Of particular interest was the measurement of artificial lumen narrowing (ALN) caused by the stent material within the stented vessel segment to determine whether CTA can be used to detect in-stent restenosis. CTA appearances of 16 carotid artery stents of different designs and sizes (4.0 to 11.0 mm) were investigated in vitro. CTA was performed using 16-, 64- and 320-row CT scanners. For each stent, artificial lumen narrowing (ALN) was calculated. ALN ranged from 18.77% to 59.86%. ALN in different stents differed significantly. In most stents, ALN decreased with increasing stent diameter. In all but one stents, ALN using sharp image kernels was significantly lower than ALN using medium image kernels. Considering all stents, ALN did not significantly differ using different CT scanners or imaging protocols. CTA evaluation of vessel patency after stent placement is possible, but is considerably impaired by ALN. Investigators should be informed about the method of choice for every stent and stent manufacturers should be aware of potential artifacts caused by their stents during noninvasive diagnostic methods such as CTA. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Bouchoucha, Mongia; Akrout, Mouna; Bellali, Hédia; Bouchoucha, Rim; Tarhouni, Fadwa; Mansour, Abderraouf Ben; Zouari, Béchir
2016-01-01
Background Estimation of food portion sizes has always been a challenge in dietary studies on free-living individuals. The aim of this work was to develop and validate a food photography manual to improve the accuracy of the estimated size of consumed food portions. Methods A manual was compiled from digital photos of foods commonly consumed by the Tunisian population. The food was cooked and weighed before taking digital photographs of three portion sizes. The manual was validated by comparing the method of 24-hour recall (using photos) to the reference method [food weighing (FW)]. In both the methods, the comparison focused on food intake amounts as well as nutritional issues. Validity was assessed by Bland–Altman limits of agreement. In total, 31 male and female volunteers aged 9–89 participated in the study. Results We focused on eight food categories and compared their estimated amounts (using the 24-hour recall method) to those actually consumed (using FW). Animal products and sweets were underestimated, whereas pasta, bread, vegetables, fruits, and dairy products were overestimated. However, the difference between the two methods is not statistically significant except for pasta (p<0.05) and dairy products (p<0.05). The coefficient of correlation between the two methods is highly significant, ranging from 0.876 for pasta to 0.989 for dairy products. Nutrient intake calculated for both methods showed insignificant differences except for fat (p<0.001) and dietary fiber (p<0.05). A highly significant correlation was observed between the two methods for all micronutrients. The test agreement highlights the lack of difference between the two methods. Conclusion The difference between the 24-hour recall method using digital photos and the weighing method is acceptable. Our findings indicate that the food photography manual can be a useful tool for quantifying food portion sizes in epidemiological dietary surveys. PMID:27585631
Bouchoucha, Mongia; Akrout, Mouna; Bellali, Hédia; Bouchoucha, Rim; Tarhouni, Fadwa; Mansour, Abderraouf Ben; Zouari, Béchir
2016-01-01
Background Estimation of food portion sizes has always been a challenge in dietary studies on free-living individuals. The aim of this work was to develop and validate a food photography manual to improve the accuracy of the estimated size of consumed food portions. Methods A manual was compiled from digital photos of foods commonly consumed by the Tunisian population. The food was cooked and weighed before taking digital photographs of three portion sizes. The manual was validated by comparing the method of 24-hour recall (using photos) to the reference method [food weighing (FW)]. In both the methods, the comparison focused on food intake amounts as well as nutritional issues. Validity was assessed by Bland-Altman limits of agreement. In total, 31 male and female volunteers aged 9-89 participated in the study. Results We focused on eight food categories and compared their estimated amounts (using the 24-hour recall method) to those actually consumed (using FW). Animal products and sweets were underestimated, whereas pasta, bread, vegetables, fruits, and dairy products were overestimated. However, the difference between the two methods is not statistically significant except for pasta (p<0.05) and dairy products (p<0.05). The coefficient of correlation between the two methods is highly significant, ranging from 0.876 for pasta to 0.989 for dairy products. Nutrient intake calculated for both methods showed insignificant differences except for fat (p<0.001) and dietary fiber (p<0.05). A highly significant correlation was observed between the two methods for all micronutrients. The test agreement highlights the lack of difference between the two methods. Conclusion The difference between the 24-hour recall method using digital photos and the weighing method is acceptable. Our findings indicate that the food photography manual can be a useful tool for quantifying food portion sizes in epidemiological dietary surveys.
NASA Astrophysics Data System (ADS)
Lamie, Nesrine T.
2015-10-01
Four, accurate, precise, and sensitive spectrophotometric methods are developed for simultaneous determination of a binary mixture of amlodipine besylate (AM) and atenolol (AT). AM is determined at its λmax 360 nm (0D), while atenolol can be determined by four different methods. Method (A) is absorption factor (AF). Method (B) is the new ratio difference method (RD) which measures the difference in amplitudes between 210 and 226 nm. Method (C) is novel constant center spectrophotometric method (CC). Method (D) is mean centering of the ratio spectra (MCR) at 284 nm. The methods are tested by analyzing synthetic mixtures of the cited drugs and they are applied to their commercial pharmaceutical preparation. The validity of results is assessed by applying standard addition technique. The results obtained are found to agree statistically with those obtained by official methods, showing no significant difference with respect to accuracy and precision.
Mielnik, M B; Dainty, R H; Lundby, F; Mielnik, J
1999-07-01
The effect of evaporative air chilling on quality of fresh chicken carcasses was compared with air chilling as reference method. Cooling efficiency and total heat loss were significantly higher for evaporative air chilling. The chilling method was of great importance for weight loss. Chicken chilled in cold air lost considerably more weight than chicken cooled by evaporative air chilling; the difference was 1.8%. The chilling method also affected the skin color and the amount of moisture on skin surface. After evaporative air chilling, the chicken carcasses had a lighter color and more water on the back and under the wings. The moisture content in skin and meat, cooking loss, and pH were not affected by chilling method. Odor attributes of raw chicken and odor and flavor attributes of cooked chicken did not show any significant differences between the two chilling methods. The shelf life of chicken stored at 4 and -1 C were not affected significantly by chilling method. Storage time and temperature appeared to be the decisive factors for sensory and microbiological quality of fresh chicken carcasses.
Mehrdad, Neda; Zolfaghari, Mitra; Bahrani, Naser; Eybpoosh, Sana
2011-01-01
Traditional teaching methods used in medical education couldn't meet the need for keeping pace with up to date information. Present study has conducted in order to compare the effect of lecture and e-learning methods on nursing students' learning outcomes in the context of Iran. A cross-over design was applied. Study sample was consisted of 32 students which were in third semester of nursing bachelor program and were passing Maternal Child nursing course. The first part of the course was taught using lecture method during first four weeks; an e-learning method was the technique used to educate the remained part of the course during the second four weeks. Students' learning outcomes in each method, opinion toward and participation with both educational methods was assessed. No significant difference was found between students exam scores in both methods. Considering students' opinion toward educational methods, no significant difference was found between two methods in general but students reported better "capability" and "independency" in e-learning method while lecture was obtained higher scores in "effectiveness on learning" and "motivation" characteristics. E-learning can be used in teaching some nursing courses. It is recommended to use e-learning method with appropriate interactive strategies and attractive virtual environments to motivate students.
Body Fat Measurements in Singaporean Adults Using Four Methods
Bi, Xinyan; Loo, Yi Ting
2018-01-01
Few studies have been conducted to measure body composition in Asian populations. In this study, we determined the percent body fat (PBF) by using dual-energy X-ray absorptiometry (DEXA), air-displacement plethysmography (ADP or BOD POD), bioelectrical impedance analysis (BIA) and skinfold (SKF) in 445 healthy Singaporean adults. We observed that the BOD POD, BIA and SKF estimates of PBF were highly correlated with that from DEXA (as a reference method) among Singaporean adults. However, they all underestimated PBF (differences of 3.9% for BOD POD, 5.6% for BIA and 12.5% for SKF). Our results filled a gap in the literature by testing the relationships between DEXA and BOD POD, BIA and SKF in a large sample with a wide range of body mass index (BMI) from 16.1 to 37.5 kg/m2 and age from 21 to 69.2 years. The differences of PBF measured by different methods were dependent on age, gender and ethnicity. No significant difference was observed between DEXA and BOD POD in men aged > 40 or in BMI tertile 3. However, the mean difference between DEXA and BOD POD was significant in women. Different measuring methods of estimating PBF therefore must be cautiously interpreted. PMID:29510545
Are LOD and LOQ Reliable Parameters for Sensitivity Evaluation of Spectroscopic Methods?
Ershadi, Saba; Shayanfar, Ali
2018-03-22
The limit of detection (LOD) and the limit of quantification (LOQ) are common parameters to assess the sensitivity of analytical methods. In this study, the LOD and LOQ of previously reported terbium sensitized analysis methods were calculated by different methods, and the results were compared with sensitivity parameters [lower limit of quantification (LLOQ)] of U.S. Food and Drug Administration guidelines. The details of the calibration curve and standard deviation of blank samples of three different terbium-sensitized luminescence methods for the quantification of mycophenolic acid, enrofloxacin, and silibinin were used for the calculation of LOD and LOQ. A comparison of LOD and LOQ values calculated by various methods and LLOQ shows a considerable difference. The significant difference of the calculated LOD and LOQ with various methods and LLOQ should be considered in the sensitivity evaluation of spectroscopic methods.
Mars, Mokhtar; Bouaziz, Mouna; Tbini, Zeineb; Ladeb, Fethi; Gharbi, Souha
2018-06-12
This study aims to determine how Magnetic Resonance Imaging (MRI) acquisition techniques and calculation methods affect T2 values of knee cartilage at 1.5 Tesla and to identify sequences that can be used for high-resolution T2 mapping in short scanning times. This study was performed on phantom and twenty-nine patients who underwent MRI of the knee joint at 1.5 Tesla. The protocol includes T2 mapping sequences based on Single Echo Spin Echo (SESE), Multi-Echo Spin Echo (MESE), Fast Spin Echo (FSE) and Turbo Gradient Spin Echo (TGSE). The T2 relaxation times were quantified and evaluated using three calculation methods (MapIt, Syngo Offline and monoexponential fit). Signal to Noise Ratios (SNR) were measured in all sequences. All statistical analyses were performed using the t-test. The average T2 values in phantom were 41.7 ± 13.8 ms for SESE, 43.2 ± 14.4 ms for MESE, 42.4 ± 14.1 ms for FSE and 44 ± 14.5 ms for TGSE. In the patient study, the mean differences were 6.5 ± 8.2 ms, 7.8 ± 7.6 ms and 8.4 ± 14.2 ms for MESE, FSE and TGSE compared to SESE respectively; these statistical results were not significantly different (p > 0.05). The comparison between the three calculation methods showed no significant difference (p > 0.05). t-Test showed no significant difference between SNR values for all sequences. T2 values depend not only on the sequence type but also on the calculation method. None of the sequences revealed significant differences compared to the SESE reference sequence. TGSE with its short scanning time can be used for high-resolution T2 mapping. ©2018The Author(s). Published by S. Karger AG, Basel.
Benetz, B A; Diaconu, E; Bowlin, S J; Oak, S S; Laing, R A; Lass, J H
1999-01-01
Compare corneal endothelial image analysis by Konan SP8000 and Bio-Optics Bambi image-analysis systems. Corneal endothelial images from 98 individuals (191 eyes), ranging in age from 4 to 87 years, with a normal slit-lamp examination and no history of ocular trauma, intraocular surgery, or intraocular inflammation were obtained by the Konan SP8000 noncontact specular microscope. One observer analyzed these images by using the Konan system and a second observer by using the Bio-Optics Bambi system. Three methods of analyses were used: a fixed-frame method to obtain cell density (for both Konan and Bio-Optics Bambi) and a "dot" (Konan) or "corners" (Bio-Optics Bambi) method to determine morphometric parameters. The cell density determined by the Konan fixed-frame method was significantly higher (157 cells/mm2) than the Bio-Optics Bambi fixed-frame method determination (p<0.0001). However, the difference in cell density, although still statistically significant, was smaller and reversed comparing the Konan fixed-frame method with both Konan dot and Bio-Optics Bambi comers method (-74 cells/mm2, p<0.0001; -55 cells/mm2, p<0.0001, respectively). Small but statistically significant morphometric analyses differences between Konan and Bio-Optics Bambi were seen: cell density, +19 cells/mm2 (p = 0.03); cell area, -3.0 microm2 (p = 0.008); and coefficient of variation, +1.0 (p = 0.003). There was no statistically significant difference between these two methods in the percentage of six-sided cells detected (p = 0.55). Cell densities measured by the Konan fixed-frame method were comparable with Konan and Bio-Optics Bambi's morphometric analysis, but not with the Bio-Optics Bambi fixed-frame method. The two morphometric analyses were comparable with minimal or no differences for the parameters that were studied. The Konan SP8000 endothelial image-analysis system may be useful for large-scale clinical trials determining cell loss; its noncontact system has many clinical benefits (including patient comfort, safety, ease of use, and short procedure time) and provides reliable cell-density calculations.
Validation of the Use of Dried Blood Spot (DBS) Method to Assess Vitamin A Status
Fallah, Elham; Peighambardoust, Seyed Hadi
2012-01-01
Background: Vitamin A deficiency is an important dietary deficiency in the world. Thus, the ne¬cessity of screening for deficient populations is obvious. This paper introduces a fast, cheap and relatively reliable method called “dried blood spot” (DBS) method in screening the deficient populations. The validity of this method for retinol measurement was investigated. Method: The “precision” and “agreement” criteria of the DBS method were assessed. The preci¬sion was calculated and compared with those of plasma using F-test. The agreement was eva¬luated using Bland-Altman plot. Results: The imprecision of retinol measurements in dried spots was not significantly different from those of the control (plasma). A good correlation coefficient (r2=0.78) was obtained for dried spots’ retinol measurements versus plasma’s retinol analysis (P < 0.01). Paired t-test showed no significant difference between the DBS and retinol methods on a group level. Imprecision of DBS measurement was acceptable, compared to that of the plasma method. The difference be¬tween these two methods was not statistically significant on a group level. Conclusion: Application of DBS standard samples, in which a part of the plasma was replaced with the artificial plasma, was shown to be a reliable calibration mean for retinol measurements in DBS samples. Retinol in dried spots was stable for 90 days. Overall, the DBS method provided a precise measurement of retinol, showing results that were comparable with the measurement of retinol in plasma. PMID:24688932
Miller, William R; Manuel, Jennifer Knapp
2008-09-01
Treatment research is sometimes criticised as lacking in clinical relevance, and one potential source of this friction is a disconnection between statistical significance and what clinicians regard to be a meaningful difference in outcomes. This report demonstrates a novel methodology for estimating what substance abuse practitioners regard to be clinically important differences. To illustrate the estimation method, we surveyed 50 substance abuse treatment providers participating in the National Institute on Drug Abuse (NIDA) Clinical Trials Network. Practitioners identified thresholds for clinically meaningful differences on nine common outcome variables, indicated the size of effect that would justify their learning a new treatment method and estimated current outcomes from their services. Clinicians judged a difference between two treatments to be meaningful if outcomes were improved by about 10 - 12 points on the percentage of patients totally abstaining, arrested for driving while intoxicated, employed or having abnormal liver enzymes. A 5 percentage-point reduction in patient mortality was regarded as clinically significant. On continuous outcome measures (such as percentage of days abstinent or drinks per drinking day), practitioners judged an outcome to be significant when it doubled or halved the base rate. When a new treatment meets such criteria, practitioners were interested in learning it. Effects that are statistically significant in clinical trials may be unimpressive to practitioners. Clinicians' judgements of meaningful differences can inform the powering of clinical trials.
A simple modification of the separation method reduces heterogeneity of adipose-derived stem cells.
Griesche, Nadine; Luttmann, Werner; Luttmann, Arlette; Stammermann, Thekla; Geiger, Helmut; Baer, Patrick C
2010-01-01
High hopes are put into the use of mesenchymal stem cells (MSCs) in various approaches for tissue engineering and regenerative medicine. MSCs are derived from different tissues with only small differences in their phenotype or their differentiation potential, but higher differences in the cell yield. Since fat is easily accessible and contains a high amount of MSCs to be isolated, adipose-derived stem cells (ASCs) are very promising for clinical approaches. ASCs are not a completely homogeneous cell population. Our study was initiated to explore an easy and convenient method to reduce heterogeneity. We tested different isolation methods: (1) the standard isolation method for ASCs based on plastic attachment, (2) the standard method with an initial washing step after 60 min of adherence and (3) immunomagnetic isolation by 4 typical markers (CD49a, CD90, CD105 and CD271). Cells isolated by these methods were evaluated using quantitative PCR and flow cytometry as well as by their differentiation potential. Washing led to a significantly lower expression of desmin, smA and six2, and a higher expression of the stem cell markers nestin, oct-4 and sall-1, compared to standard isolated cells, while the immunomagnetically isolated cells showed no significant changes. All cells independent of the isolation method could be induced to differentiate into adipocytes and osteoblasts. Our study demonstrates that a simple washing step reduces heterogeneity of cultured ASCs according to PCR analysis, whereas the immunomagnetic isolation only showed minor advantages compared to the standard method, but the disadvantage of significantly lower cell yields in the primary isolates. Copyright 2010 S. Karger AG, Basel.
Broom, Margaret; Ying, Lei; Wright, Audrey; Stewart, Alice; Abdel-Latif, Mohamed E; Shadbolt, Bruce; Todd, David A
2014-09-01
In our previous randomised controlled trial (RCT), we have shown in preterm babies (PBs) <30 weeks gestation that CeasIng Cpap At standarD criteriA (CICADA (method 1)) compared with cycling off continuous positive airway pressure (CPAP) gradually (method 2) or cycling off CPAP gradually with low flow air/oxygen during periods off CPAP (method 3) reduces CPAP cessation time in PBs <30 weeks gestation. This retrospective study reviewed weight gain, time to reach full feeds and time to cease caffeine in PBs previously enrolled in the RCT. Data were collected from 162 of the 177 PBs, and there was no significant difference in the projected weight gain between the three methods. Based on intention to treat, the time taken to reach full feeds for all three methods showed no significant difference. However, post hoc analysis showed the CICADA method compared with cycling off gradually just failed significance (30.3±1.6 vs 31.1±2.4 (weeks corrected gestational age (Wks CGA±SD)), p=0.077). Analysis of time to cease caffeine showed there was a significant difference between the methods with PBs randomised to the CICADA method compared with the cycling off method ceasing caffeine almost a week earlier (33.6±2.4 vs 34.5±2.8 (Wks CGA±SD), p=0.02). This retrospective study provides evidence to substantiate the optimum method of ceasing CPAP; the CICADA method, does not adversely affect weight gain, time to reach full feeds and may reduce time to cease caffeine in PBs <30 weeks gestation. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Wang, S W; Li, M; Yang, H F; Zhao, Y J; Wang, Y; Liu, Y
2016-04-18
To compare the accuracyof interactive closet point (ICP) algorithm, Procrustes analysis (PA) algorithm,and a landmark-independent method to construct the mid-sagittal plane (MSP) of the cone beam computed tomography.To provide theoretical basis for establishing coordinate systemof CBCT images and symmetric analysis. Ten patients were selected and scanned by CBCT before orthodontic treatment.The scan data was imported into Mimics 10.0 to reconstructthree dimensional skulls.And the MSP of each skull was generated by ICP algorithm, PA algorithm and landmark-independent method. MSP extracted by ICP algorithm or PA algorithm involvedthree steps. First, the 3D skull processing was performed by reverse engineering software geomagic studio 2012 to obtain the mirror skull. Then, the original and its mirror skull was registered separately by ICP algorithm in geomagic studio 2012 and PA algorithm in NX Imageware 11.0. Finally, the registered data were united into new data to calculate the MSP of the originaldata in geomagic studio 2012. The mid-sagittal plane was determined by SELLA (S), nasion (N), basion (Ba) as traditional landmark-dependent methodconducted in software InVivoDental 5.0. The distance from 9 pairs of symmetric anatomical marked points to three sagittal plane were measured and calculated to compare the differences of the absolute value. The one-way ANOVA test was used to analyze the variable differences among the 3 MSPs. The pairwise comparison was performed with LSD method. MSPs calculated by the three methods were available for clinic analysis, which could be concluded from the front view.However, there was significant differences among the distances from the 9 pairs of symmetric anatomical marked points to the MSPs (F=10.932,P=0.001).LSD test showed there was no significant difference between the ICP algorithm and landmark-independent method (P=0.11), while there was significant difference between the PA algorithm and landmark-independent methods (P=0.01) . Mid-sagittal plane of 3D skulls could be generated base on ICP algorithm or PA algorithm. There was no significant difference between the ICP algorithm and landmark-independent method. For the subjects with no evident asymmetry, ICP algorithm is feasible in clinical analysis.
Pharmacokinetics of orally administered DL-α-lipoic acid in dogs.
Zicker, Steven C; Avila, Albert; Joshi, Dinesh K; Gross, Kathy L
2010-11-01
To determine the pharmacokinetics of DL-α-lipoic acid in dogs when administered at 3 dosages via 3 methods of delivery. 27 clinically normal Beagles. In a 3 × 3 factorial Latin square design, 3 dosages (2.5, 12.5, and 25 mg/kg) of DL-α-lipoic acid were administered orally in a capsule form and provided without a meal, in a capsule form and provided with a meal, and as an ingredient included in an extruded dog food. Food was withheld for 12 hours prior to DL-α-lipoic acid administration. Blood samples were collected before (0 minutes) and at 15, 30, 45, 60, and 120 minutes after administration. Plasma concentrations of DL-α-lipoic acid were determined via high-performance liquid chromatography. A generalized linear models procedure was used to evaluate the effects of method of delivery and dosage. Noncompartmental analysis was used to determine pharmacokinetic parameters of DL-α-lipoic acid. Nonparametric tests were used to detect significant differences between pharmacokinetic parameters among treatment groups. A significant effect of dosage was observed regardless of delivery method. Method of delivery also significantly affected plasma concentrations of DL-α-lipoic acid, with extruded foods resulting in lowest concentration for each dosage administered. Maximum plasma concentration was significantly affected by method of delivery at each dosage administered. Other significant changes in pharmacokinetic parameters were variable and dependent on dosage and method of delivery. Values for pharmacokinetic parameters of orally administered DL-α-lipoic acid may differ significantly when there are changes in dosage, method of administration, and fed status.
Kundoor, Vipra; Dalby, Richard N
2010-01-01
To develop a simple and inexpensive method to visualize and quantify droplet deposition patterns. Deposition pattern was determined by uniformly coating the nose model with Sar-Gel (a paste that changes from white to purple on contact with water) and subsequently discharging sprays into the nose model. The color change was captured using a digital camera and analyzed using Adobe Photoshop. Several tests were conducted to validate the method. Deposition patterns of different nasal sprays (Ayr, Afrin, and Zicam) and different nasal drug delivery devices (Afrin nasal spray and PARI Sinustar nasal nebulizer) were compared. We also used the method to evaluate the effect of inhaled flow rate on nasal spray deposition. There was a significant difference in the deposition area for Ayr, Afrin, and Zicam. The deposition areas of Afrin nasal spray and PARI Sinustar nasal nebulizer (2 min and 5 min) were significantly different. Inhaled flow rate did not have a significant effect on the deposition pattern. Lower viscosity formulations (Ayr, Afrin) provided greater coverage than the higher viscosity formulation (Zicam). The nebulizer covered a greater surface area than the spray pump we evaluated. Aerosol deposition in the nose model was not affected by air flow conditions.
Iglesias, Juan Eugenio; Van Leemput, Koen; Augustinack, Jean; Insausti, Ricardo; Fischl, Bruce; Reuter, Martin
2016-11-01
The hippocampal formation is a complex, heterogeneous structure that consists of a number of distinct, interacting subregions. Atrophy of these subregions is implied in a variety of neurodegenerative diseases, most prominently in Alzheimer's disease (AD). Thanks to the increasing resolution of MR images and computational atlases, automatic segmentation of hippocampal subregions is becoming feasible in MRI scans. Here we introduce a generative model for dedicated longitudinal segmentation that relies on subject-specific atlases. The segmentations of the scans at the different time points are jointly computed using Bayesian inference. All time points are treated the same to avoid processing bias. We evaluate this approach using over 4700 scans from two publicly available datasets (ADNI and MIRIAD). In test-retest reliability experiments, the proposed method yielded significantly lower volume differences and significantly higher Dice overlaps than the cross-sectional approach for nearly every subregion (average across subregions: 4.5% vs. 6.5%, Dice overlap: 81.8% vs. 75.4%). The longitudinal algorithm also demonstrated increased sensitivity to group differences: in MIRIAD (69 subjects: 46 with AD and 23 controls), it found differences in atrophy rates between AD and controls that the cross sectional method could not detect in a number of subregions: right parasubiculum, left and right presubiculum, right subiculum, left dentate gyrus, left CA4, left HATA and right tail. In ADNI (836 subjects: 369 with AD, 215 with early cognitive impairment - eMCI - and 252 controls), all methods found significant differences between AD and controls, but the proposed longitudinal algorithm detected differences between controls and eMCI and differences between eMCI and AD that the cross sectional method could not find: left presubiculum, right subiculum, left and right parasubiculum, left and right HATA. Moreover, many of the differences that the cross-sectional method already found were detected with higher significance. The presented algorithm will be made available as part of the open-source neuroimaging package FreeSurfer. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
Henderson, Gemma; Cox, Faith; Kittelmann, Sandra; Miri, Vahideh Heidarian; Zethof, Michael; Noel, Samantha J.; Waghorn, Garry C.; Janssen, Peter H.
2013-01-01
Molecular microbial ecology techniques are widely used to study the composition of the rumen microbiota and to increase understanding of the roles they play. Therefore, sampling and DNA extraction methods that result in adequate yields of microbial DNA that also accurately represents the microbial community are crucial. Fifteen different methods were used to extract DNA from cow and sheep rumen samples. The DNA yield and quality, and its suitability for downstream PCR amplifications varied considerably, depending on the DNA extraction method used. DNA extracts from nine extraction methods that passed these first quality criteria were evaluated further by quantitative PCR enumeration of microbial marker loci. Absolute microbial numbers, determined on the same rumen samples, differed by more than 100-fold, depending on the DNA extraction method used. The apparent compositions of the archaeal, bacterial, ciliate protozoal, and fungal communities in identical rumen samples were assessed using 454 Titanium pyrosequencing. Significant differences in microbial community composition were observed between extraction methods, for example in the relative abundances of members of the phyla Bacteroidetes and Firmicutes. Microbial communities in parallel samples collected from cows by oral stomach-tubing or through a rumen fistula, and in liquid and solid rumen digesta fractions, were compared using one of the DNA extraction methods. Community representations were generally similar, regardless of the rumen sampling technique used, but significant differences in the abundances of some microbial taxa such as the Clostridiales and the Methanobrevibacter ruminantium clade were observed. The apparent microbial community composition differed between rumen sample fractions, and Prevotellaceae were most abundant in the liquid fraction. DNA extraction methods that involved phenol-chloroform extraction and mechanical lysis steps tended to be more comparable. However, comparison of data from studies in which different sampling techniques, different rumen sample fractions or different DNA extraction methods were used should be avoided. PMID:24040342
Henderson, Gemma; Cox, Faith; Kittelmann, Sandra; Miri, Vahideh Heidarian; Zethof, Michael; Noel, Samantha J; Waghorn, Garry C; Janssen, Peter H
2013-01-01
Molecular microbial ecology techniques are widely used to study the composition of the rumen microbiota and to increase understanding of the roles they play. Therefore, sampling and DNA extraction methods that result in adequate yields of microbial DNA that also accurately represents the microbial community are crucial. Fifteen different methods were used to extract DNA from cow and sheep rumen samples. The DNA yield and quality, and its suitability for downstream PCR amplifications varied considerably, depending on the DNA extraction method used. DNA extracts from nine extraction methods that passed these first quality criteria were evaluated further by quantitative PCR enumeration of microbial marker loci. Absolute microbial numbers, determined on the same rumen samples, differed by more than 100-fold, depending on the DNA extraction method used. The apparent compositions of the archaeal, bacterial, ciliate protozoal, and fungal communities in identical rumen samples were assessed using 454 Titanium pyrosequencing. Significant differences in microbial community composition were observed between extraction methods, for example in the relative abundances of members of the phyla Bacteroidetes and Firmicutes. Microbial communities in parallel samples collected from cows by oral stomach-tubing or through a rumen fistula, and in liquid and solid rumen digesta fractions, were compared using one of the DNA extraction methods. Community representations were generally similar, regardless of the rumen sampling technique used, but significant differences in the abundances of some microbial taxa such as the Clostridiales and the Methanobrevibacter ruminantium clade were observed. The apparent microbial community composition differed between rumen sample fractions, and Prevotellaceae were most abundant in the liquid fraction. DNA extraction methods that involved phenol-chloroform extraction and mechanical lysis steps tended to be more comparable. However, comparison of data from studies in which different sampling techniques, different rumen sample fractions or different DNA extraction methods were used should be avoided.
Awais, Muhammad; Nadeem, Naila; Husen, Yousuf; Rehman, Abdul; Beg, Madiha; Khattak, Yasir Jamil
2014-12-01
To compare Greulich-Pyle (GP) and Girdany-Golden (GG) methods for estimation of Skeletal Age (SA) in children referred to a tertiary care hospital in Karachi, Pakistan. Cross-sectional study. Department of Radiology, The Aga Khan University Hospital, Karachi, Pakistan, from July 2010 to June 2012. Children up to the age of 18 years, who had undergone X-ray for the evaluation of trauma were included. Each X-ray was interpreted using both methods by two consultant paediatric radiologists having at least 10 years experience, who were blinded to the actual Chronologic Age (CA) of children. A total of 283 children were included. No significant difference was noted in mean SA estimated by GP method and mean CA for female children (p=0.695). However, a significant difference was noted between mean CA and mean SA by GG method for females (p=0.011). For males, there was a significant difference between mean CA and mean SA estimated by both GP and GG methods. A stronger correlation was found between CA and SA estimated by GP method (r=0.943 for girls, r=0.915 for boys) as compared to GG method (r=0.909 for girls, r=0.865 for boys) respectively. Bland- Altman analysis also revealed that the two methods cannot be used interchangeably. Excellent correlation was seen between the two readers for both GP and GG methods. There was no additional benefit of using GP and GG methods simultaneously over using GP method alone. Moreover, although GP was reliable in estimating SA in girls, it was unable to accurately assess SA in boys. Therefore, it would be ideal to develop indigenous standards of bone age estimation based on a representative sample of healthy native children.
Inada, Satoshi; Masuda, Takanori; Maruyama, Naoya; Yamashita, Yukari; Sato, Tomoyasu; Imada, Naoyuki
2016-01-01
To evaluate the image quality and effect of radiation dose reduction by setting for computed tomography automatic exposure control system (CT-AEC) in computed tomographic angiography (CTA) of lower extremity artery. Two methods of setting were compared for CT-AEC [conventional and contrast-to-noise ratio (CNR) methods]. Conventional method was set noise index (NI): 14and tube current threshold: 10-750 mA. CNR method was set NI: 18, minimum tube current: (X+Y)/2 mA (X, Y: maximum X (Y)-axis tube current value of leg in NI: 14), and maximum tube current: 750 mA. The image quality was evaluated by CNR, and radiation dose reduction was evaluated by dose-length-product (DLP). In conventional method, mean CNRs for pelvis, femur, and leg were 19.9±4.8, 20.4±5.4, and 16.2±4.3, respectively. There was a significant difference between the CNRs of pelvis and leg (P<0.001), and between femur and leg (P<0.001). In CNR method, mean CNRs for pelvis, femur, and leg were 15.2±3.3, 15.3±3.2, and 15.3±3.1, respectively; no significant difference between pelvis, femur, and leg (P=0.973) in CNR method was observed. Mean DLPs were 1457±434 mGy⋅cm in conventional method, and 1049±434 mGy·cm in CNR method. There was a significant difference in the DLPs of conventional method and CNR method (P<0.001). CNR method gave equal CNRs for pelvis, femur, and leg, and was beneficial for radiation dose reduction in CTA of lower extremity artery.
[Optimized application of nested PCR method for detection of malaria].
Yao-Guang, Z; Li, J; Zhen-Yu, W; Li, C
2017-04-28
Objective To optimize the application of the nested PCR method for the detection of malaria according to the working practice, so as to improve the efficiency of malaria detection. Methods Premixing solution of PCR, internal primers for further amplification and new designed primers that aimed at two Plasmodium ovale subspecies were employed to optimize the reaction system, reaction condition and specific primers of P . ovale on basis of routine nested PCR. Then the specificity and the sensitivity of the optimized method were analyzed. The positive blood samples and examination samples of malaria were detected by the routine nested PCR and the optimized method simultaneously, and the detection results were compared and analyzed. Results The optimized method showed good specificity, and its sensitivity could reach the pg to fg level. The two methods were used to detect the same positive malarial blood samples simultaneously, the results indicated that the PCR products of the two methods had no significant difference, but the non-specific amplification reduced obviously and the detection rates of P . ovale subspecies improved, as well as the total specificity also increased through the use of the optimized method. The actual detection results of 111 cases of malarial blood samples showed that the sensitivity and specificity of the routine nested PCR were 94.57% and 86.96%, respectively, and those of the optimized method were both 93.48%, and there was no statistically significant difference between the two methods in the sensitivity ( P > 0.05), but there was a statistically significant difference between the two methods in the specificity ( P < 0.05). Conclusion The optimized PCR can improve the specificity without reducing the sensitivity on the basis of the routine nested PCR, it also can save the cost and increase the efficiency of malaria detection as less experiment links.
Comparison of guinea-pig serum lipoproteins after iodination by two different methods.
Weech, P K; McTaggart, F; Mills, G L
1978-01-01
1. Guinea-pig low-density lipoproteins were isolated by ultracentrifugation and iodinated either by the IC1 method or by the chloramine-T procedure. 2. The efficiency of labelling by both methods was essentially the same. 3. When the two products were compared by ultracentrifugation, gel chromatography and immunodiffusion analysis, no significant difference in their properties was detected. 4. When they were compared by gradient-gel electrophoresis, aggregates were found in the product of the IC1 method, but not in the lipoprotein iodinated by the chloramine-T process. 5. Both products were metabolized by the guinea pig with essentially the same fractional catabolic rate. 6. The fractional catabolic rate of lipoprotein iodinated by the chloramine-T method was not significantly different from that of lipoprotein biologically labelled in the protein moiety with [75Se]selenomethionine. 7. It is concluded that the products of both methods of iodination are almost equally acceptable, provided that the optimum conditions for the chloramine-T reaction are carefully established. Images Fig. 4. Fig. 5. PMID:206260
NASA Astrophysics Data System (ADS)
Field, S. N.; Glassom, D.; Bythell, J.
2007-06-01
The choice of substrata and the methods of deployment in analyses of settlement in benthic communities are often driven by the cost of materials and their local availability, and comparisons are often made between studies using different methodologies. The effects of varying artificial substratum, size of replicates and method of deployment were determined on a shallow reef in Eilat, Israel, while the effect of size of replicates was also investigated on a shallow reef in Sharm El Sheikh, Egypt. When statistical power was high enough, that is, when sufficient numbers of settlers were recorded, significant differences were found between materials used, tile size and methods of deployment. Significant differences were detected in total coral settlement rates and for the two dominant taxonomic groups, acroporids and pocilloporids. Standardisation of tile materials, dimensions, and method of deployment is needed for comparison between coral and other epibiont settlement studies. However, a greater understanding of the effects of these experimental variables on settlement processes may enable retrospective comparisons between studies utilising a range of materials and methods.
Modified gastroduodenostomy in laparoscopy-assisted distal gastrectomy: a 'tornado' anastomosis.
Kubota, Keisuke; Kuroda, Junko; Yoshida, Masashi; Okada, Akihiro; Nitori, Nobuhiro; Kitajima, Masaki
2013-01-01
This study was to examine the utility of a modified double-stapling end-to-end gastroduodenostomy method ('Tornado' anastomosis) compared to a method with an additional gastrotomy ('Anterior Incision' method) in laparoscopy-assisted distal gastrectomy. Forty-two patients with gastric cancer who underwent laparoscopy-assisted distal gastrectomy were analyzed retrospectively. Billroth-I using an additional gastrotomy was performed in 24 patients (AI group) and Billroth-I without an additional gastrotomy was performed in 18 (TOR group). Clinicopathological features, operative outcomes (lymph node dissection, operative time, operative blood loss) and postoperative outcomes (complications, postoperative hospital stay, and body weight loss at one year after surgery) were evaluated and compared between groups. Operative time was significantly shorter in the TOR group (251 min) than in the AI group (282 min) (p < 0.01). There were no statistically significant differences in operative blood loss, postoperative complications, and hospital stay between the 2 study groups. Body weight loss at one year after surgery was -5.8 kg in the TOR group and -6.5 kg in the AI group, without a statistically significant difference. Completion time for Billroth-I anastomosis was significantly shorter with Tornado anastomosis than with the Anterior Incision method, with safety equal between the two methods.
Accurate Simulation and Detection of Coevolution Signals in Multiple Sequence Alignments
Ackerman, Sharon H.; Tillier, Elisabeth R.; Gatti, Domenico L.
2012-01-01
Background While the conserved positions of a multiple sequence alignment (MSA) are clearly of interest, non-conserved positions can also be important because, for example, destabilizing effects at one position can be compensated by stabilizing effects at another position. Different methods have been developed to recognize the evolutionary relationship between amino acid sites, and to disentangle functional/structural dependencies from historical/phylogenetic ones. Methodology/Principal Findings We have used two complementary approaches to test the efficacy of these methods. In the first approach, we have used a new program, MSAvolve, for the in silico evolution of MSAs, which records a detailed history of all covarying positions, and builds a global coevolution matrix as the accumulated sum of individual matrices for the positions forced to co-vary, the recombinant coevolution, and the stochastic coevolution. We have simulated over 1600 MSAs for 8 protein families, which reflect sequences of different sizes and proteins with widely different functions. The calculated coevolution matrices were compared with the coevolution matrices obtained for the same evolved MSAs with different coevolution detection methods. In a second approach we have evaluated the capacity of the different methods to predict close contacts in the representative X-ray structures of an additional 150 protein families using only experimental MSAs. Conclusions/Significance Methods based on the identification of global correlations between pairs were found to be generally superior to methods based only on local correlations in their capacity to identify coevolving residues using either simulated or experimental MSAs. However, the significant variability in the performance of different methods with different proteins suggests that the simulation of MSAs that replicate the statistical properties of the experimental MSA can be a valuable tool to identify the coevolution detection method that is most effective in each case. PMID:23091608
Choi, Jung-Han; Lim, Young-Jun; Kim, Chang-Whe; Kim, Myung-Joo
2009-01-01
This study evaluated the effect of different screw-tightening sequences, forces, and methods on the stresses generated on a well-fitting internal-connection implant (Astra Tech) superstructure. A metal framework directly connected to four parallel implants was fabricated on a fully edentulous mandibular resin model. Six stone casts with four implant replicas were made from a pickup impression of the superstructure to represent a "well-fitting" situation. Stresses generated by four screw-tightening sequences (1-2-3-4, 4-3-2-1, 2-4-3-1, and 2-3-1-4), two forces (10 and 20 Ncm), and two methods (one-step and two-step) were evaluated. In the two-step method, screws were tightened to the initial torque (10 Ncm) in a predetermined screw-tightening sequence and then to the final torque (20 Ncm) in the same sequence. Stresses were recorded twice by three strain gauges attached to the framework (superior face midway between abutments). Deformation data were analyzed using multiple analysis of variance at a .05 level of statistical significance. In all stone casts, stresses were produced by the superstructure connection, regardless of screw-tightening sequence, force, and method. No statistically significant differences for superstructure preload stresses were found based on screw-tightening sequences (-180.0 to -181.6 microm/m) or forces (-163.4 and -169.2 microm/m) (P > .05). However, different screw-tightening methods induced different stresses on the superstructure. The two-step screw-tightening method (-180.1 microm/m) produced significantly higher stress than the one-step method (-169.2 microm/m) (P = .0457). Within the limitations of this in vitro study, screw-tightening sequence and force were not critical factors in the stress generated on a well-fitting internal-connection implant superstructure. The stress caused by the two-step method was greater than that produced using the one-step method. Further studies are needed to evaluate the effect of screw-tightening techniques on preload stress in various different clinical situations.
Bouchoucha, Mongia; Akrout, Mouna; Bellali, Hédia; Bouchoucha, Rim; Tarhouni, Fadwa; Mansour, Abderraouf Ben; Zouari, Béchir
2016-01-01
Estimation of food portion sizes has always been a challenge in dietary studies on free-living individuals. The aim of this work was to develop and validate a food photography manual to improve the accuracy of the estimated size of consumed food portions. A manual was compiled from digital photos of foods commonly consumed by the Tunisian population. The food was cooked and weighed before taking digital photographs of three portion sizes. The manual was validated by comparing the method of 24-hour recall (using photos) to the reference method [food weighing (FW)]. In both the methods, the comparison focused on food intake amounts as well as nutritional issues. Validity was assessed by Bland-Altman limits of agreement. In total, 31 male and female volunteers aged 9-89 participated in the study. We focused on eight food categories and compared their estimated amounts (using the 24-hour recall method) to those actually consumed (using FW). Animal products and sweets were underestimated, whereas pasta, bread, vegetables, fruits, and dairy products were overestimated. However, the difference between the two methods is not statistically significant except for pasta (p<0.05) and dairy products (p<0.05). The coefficient of correlation between the two methods is highly significant, ranging from 0.876 for pasta to 0.989 for dairy products. Nutrient intake calculated for both methods showed insignificant differences except for fat (p<0.001) and dietary fiber (p<0.05). A highly significant correlation was observed between the two methods for all micronutrients. The test agreement highlights the lack of difference between the two methods. The difference between the 24-hour recall method using digital photos and the weighing method is acceptable. Our findings indicate that the food photography manual can be a useful tool for quantifying food portion sizes in epidemiological dietary surveys.
Lederhuber, Hans; Stiede, Franziska; Axer, Stephan; Dahlstrand, Ursula
2017-11-01
The issue of mesh fixation in endoscopic inguinal hernia repair is frequently debated and still no conclusive data exist on differences between methods regarding long-term outcome and postoperative complications. The quantity of trials and the simultaneous lack of high-quality evidence raise the question how future trials should be planned. PubMed, EMBASE and the Cochrane Library were searched, using the filters "randomised clinical trials" and "humans". Trials that compared one method of mesh fixation with another fixation method or with non-fixation in endoscopic inguinal hernia repair were eligible. To be included, the trial was required to have assessed at least one of the following primary outcome parameters: recurrence; surgical site infection; chronic pain; or quality-of-life. Fourteen trials assessing 2161 patients and 2562 hernia repairs were included. Only two trials were rated as low risk for bias. Eight trials evaluated recurrence or surgical site infection; none of these could show significant differences between methods of fixation. Two of 11 trials assessing chronic pain described significant differences between methods of fixation. One of two trials evaluating quality-of-life showed significant differences between fixation methods in certain functions. High-quality evidence for differences between the assessed mesh fixation techniques is still lacking. From a socioeconomic and ethical point of view, it is necessary that future trials will be properly designed. As small- and medium-sized single-centre trials have proven unable to find answers, register studies or multi-centre studies with an evident focus on methodology and study design are needed in order to answer questions about mesh fixation in inguinal hernia repair.
A safe and effective method for treatment of chronic subdural haematoma.
Gurelik, Mustafa; Aslan, Adem; Gurelik, Bilge; Ozum, Unal; Karadag, Ozen; Kars, H Zafer
2007-02-01
Burr-hole irrigation and burr-hole drainage without irrigation are the most popular methods for treatment of chronic subdural haematoma. It is not well known if irrigation is necessary or which method has a higher recurrence rate. We compared the recurrence rates of those two methods. Forty-two patients were treated by burr-hole irrigation (irrigation group), whereas 38 patients were treated by burr-hole drainage (drainage group). Recurrence rate and its relation with sex, age, haematoma localization and aetiology were investigated in both groups. There was no significant difference between recurrence rates of the two groups. There was also no correlation between recurrence rate and age, sex, haematoma localization, or aetiology. There was no significant difference between recurrence rates of the two groups. Since the burr-hole drainage method is simpler to carry out, its use may be preferable.
Harland, S; Legge, G E; Luebker, A
1998-03-01
Most people with low vision need magnification to read. Page navigation is the process of moving a magnifier during reading. Modern electronic technology can provide many alternatives for navigating through text. This study compared reading speeds for four methods of displaying text. The four methods varied in their page-navigation demands. The closed-circuit television (CCTV) and MOUSE methods involved manual navigation. The DRIFT method (horizontally drifting text) involved no manual navigation, but did involve both smooth-pursuit and saccadic eye movements. The rapid serial visual presentation (RSVP) method involved no manual navigation, and relatively few eye movements. There were 7 normal subjects and 12 low-vision subjects (7 with central-field loss, CFL group, and 5 with central fields intact, CFI group). The subjects read 70-word passages at speeds that yielded good comprehension. Taking the CCTV reading speed as a benchmark, neither the normal nor low-vision subjects had significantly different speeds with the MOUSE method. As expected from the reduced navigational demands, normal subjects read faster with the DRIFT method (85% faster) and the RSVP method (169%). The CFI group read significantly faster with DRIFT (43%) and RSVP (38%). The CFL group showed no significant differences in reading speed for the four methods.
Gao, Huilin; Dong, Lihu; Li, Fengri; Zhang, Lianjun
2015-01-01
A total of 89 trees of Korean pine (Pinus koraiensis) were destructively sampled from the plantations in Heilongjiang Province, P.R. China. The sample trees were measured and calculated for the biomass and carbon stocks of tree components (i.e., stem, branch, foliage and root). Both compatible biomass and carbon stock models were developed with the total biomass and total carbon stocks as the constraints, respectively. Four methods were used to evaluate the carbon stocks of tree components. The first method predicted carbon stocks directly by the compatible carbon stocks models (Method 1). The other three methods indirectly predicted the carbon stocks in two steps: (1) estimating the biomass by the compatible biomass models, and (2) multiplying the estimated biomass by three different carbon conversion factors (i.e., carbon conversion factor 0.5 (Method 2), average carbon concentration of the sample trees (Method 3), and average carbon concentration of each tree component (Method 4)). The prediction errors of estimating the carbon stocks were compared and tested for the differences between the four methods. The results showed that the compatible biomass and carbon models with tree diameter (D) as the sole independent variable performed well so that Method 1 was the best method for predicting the carbon stocks of tree components and total. There were significant differences among the four methods for the carbon stock of stem. Method 2 produced the largest error, especially for stem and total. Methods 3 and Method 4 were slightly worse than Method 1, but the differences were not statistically significant. In practice, the indirect method using the mean carbon concentration of individual trees was sufficient to obtain accurate carbon stocks estimation if carbon stocks models are not available. PMID:26659257
Method for estimating the morphological significance of simple forms of crystals from X-ray data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Treivus, E. B., E-mail: sbobr1@bk.ru
2010-09-15
When developing V.I. Mikheev and I.I. Shafranovskii's method for estimating the morphological significance of faces of different simple forms from X-ray reflection intensities, a way to approximately evaluate the morphological significance of simple forms on crystals from the structure amplitudes of the corresponding atomic planes is proposed. The potential for this approach is demonstrated by the examples of marcasite and zircon.
Human Body 3D Posture Estimation Using Significant Points and Two Cameras
Juang, Chia-Feng; Chen, Teng-Chang; Du, Wei-Chin
2014-01-01
This paper proposes a three-dimensional (3D) human posture estimation system that locates 3D significant body points based on 2D body contours extracted from two cameras without using any depth sensors. The 3D significant body points that are located by this system include the head, the center of the body, the tips of the feet, the tips of the hands, the elbows, and the knees. First, a linear support vector machine- (SVM-) based segmentation method is proposed to distinguish the human body from the background in red, green, and blue (RGB) color space. The SVM-based segmentation method uses not only normalized color differences but also included angle between pixels in the current frame and the background in order to reduce shadow influence. After segmentation, 2D significant points in each of the two extracted images are located. A significant point volume matching (SPVM) method is then proposed to reconstruct the 3D significant body point locations by using 2D posture estimation results. Experimental results show that the proposed SVM-based segmentation method shows better performance than other gray level- and RGB-based segmentation approaches. This paper also shows the effectiveness of the 3D posture estimation results in different postures. PMID:24883422
Evaluation of pulse-oximetry oxygen saturation taken through skin protective covering
James, Jyotsna; Tiwari, Lokesh; Upadhyay, Pramod; Sreenivas, Vishnubhatla; Bhambhani, Vikas; Puliyel, Jacob M
2006-01-01
Background The hard edges of adult finger clip probes of the pulse oximetry oxygen saturation (POOS) monitor can cause skin damage if used for prolonged periods in a neonate. Covering the skin under the probe with Micropore surgical tape or a gauze piece might prevent such injury. The study was done to see if the protective covering would affect the accuracy of the readings. Methods POOS was studied in 50 full-term neonates in the first week of life. After obtaining consent from their parents the neonates had POOS readings taken directly (standard technique) and through the protective covering. Bland-Altman plots were used to compare the new method with the standard technique. A test of repeatability for each method was also performed. Results The Bland-Altman plots suggest that there is no significant loss of accuracy when readings are taken through the protective covering. The mean difference was 0.06 (SD of 1.39) and 0.04 (SD 1.3) with Micropore and gauze respectively compared to the standard method. The mean difference was 0.22 (SD 0.23) on testing repeatability with the standard method. Conclusion Interposing Micropore or gauze does not significantly affect the accuracy of the POOS reading. The difference between the standard method and the new method was less than the difference seen on testing repeatability of the standard method. PMID:16677394
Heinrich, Andreas; Teichgräber, Ulf K; Güttler, Felix V
2015-12-01
The standard ASTM F2119 describes a test method for measuring the size of a susceptibility artifact based on the example of a passive implant. A pixel in an image is considered to be a part of an image artifact if the intensity is changed by at least 30% in the presence of a test object, compared to a reference image in which the test object is absent (reference value). The aim of this paper is to simplify and accelerate the test method using a histogram-based reference value. Four test objects were scanned parallel and perpendicular to the main magnetic field, and the largest susceptibility artifacts were measured using two methods of reference value determination (reference image-based and histogram-based reference value). The results between both methods were compared using the Mann-Whitney U-test. The difference between both reference values was 42.35 ± 23.66. The difference of artifact size was 0.64 ± 0.69 mm. The artifact sizes of both methods did not show significant differences; the p-value of the Mann-Whitney U-test was between 0.710 and 0.521. A standard-conform method for a rapid, objective, and reproducible evaluation of susceptibility artifacts could be implemented. The result of the histogram-based method does not significantly differ from the ASTM-conform method.
Koponen, Jonna; Pyörälä, Eeva; Isotalus, Pekka
2012-01-01
Despite numerous studies exploring medical students' attitudes to communication skills learning (CSL), there are apparently no studies comparing different experiential learning methods and their influence on students' attitudes. We compared medical students' attitudes to learning communication skills before and after a communication course in the data as a whole, by gender and when divided into three groups using different methods. Second-year medical students (n = 129) were randomly assigned to three groups. In group A (n = 42) the theatre in education method, in group B (n = 44) simulated patients and in group C (n = 43) role-play were used. The data were gathered before and after the course using Communication Skills Attitude Scale. Students' positive attitudes to learning communication skills (PAS; positive attitude scale) increased significantly and their negative attitudes (NAS; negative attitude scale) decreased significantly between the beginning and end of the course. Female students had more positive attitudes than the male students. There were no significant differences in the three groups in the mean scores for PAS or NAS measured before or after the course. The use of experiential methods and integrating communication skills training with visits to health centres may help medical students to appreciate the importance of CSL.
Potteiger, J A; Jacobsen, D J; Donnelly, J E
2002-01-01
We examined three methods for calculating the area under the curve (AUC) following an oral glucose tolerance test (OGTT) in overweight adults prior to and after 9 months of exercise. Subjects (n=27) were randomly assigned to a control (CON, n=9) or intervention (INT, n=18) group. INT performed supervised exercise 5 days per week, 45 min per session, at 65% of heart rate reserve. OGTTs were administered pre- and post-training. Blood was collected during a 75 g OGTT and analyzed for glucose (GLU) and insulin (INS) concentrations. AUCs were calculated using the incremental, positive incremental, and total AUC methods and the difference scores for pre- and post-training were determined. No differences were observed among the methods for glucose AUC for either group. Significant differences were observed for INT insulin AUC with total AUC (1525+/-3291 microU/1/180 min) significantly greater than incremental AUC (1112+/-3229 microU/1/180 min) or positive incremental AUC (1085+/-3195 microU/I/180 min). Total insulin AUC was significantly reduced following training for INT, while incremental and positive incremental insulin AUCs showed no change. These data suggest that the method of used to calculate AUC may affect the interpretation of whether or not an intervention was effective.
Kohari, Daisuke; Takakura, Azusa
2017-12-01
We conducted a questionnaire investigation among breeding farmers to clarify the actual conditions of maternal rejection in Japanese Black cattle. We asked keeping experience of maternal rejective cows and compared occurrence patterns, rejective behavior manners, birth assistance methods, colostrum feeding method for calves, parity and rearing conditions of the cows. We found that 24% of the farms had kept rejective cows and 6% of the cows in these farms indicated maternal rejections. The most common occurrence pattern was 'Occurred from the first birth (65.6%)' and behavior manner was performing no maternal grooming with aggressive behavior (75%). Almost all the farmers assisted in each parturition (P < 0.05). There was not a significant difference among the colostrum feeding methods, but a significant difference in the rearing conditions of the cows, except for the cows with no data (P < 0.005). The parity of the rejective cows did not significantly differ in association with rejective behavior manners, birth assistance methods, colostrum feeding methods or rearing conditions. These results suggest that the occurrence rate of maternal rejection in Japanese Black cattle was approximately 6% and many of the rejective cows continuously performed no maternal grooming with aggressive behavior. © 2017 Japanese Society of Animal Science.
Park, Jeong Mee; Yong, Sang Yeol; Kim, Jong Heon; Kim, Hee; Park, Sang-Yoo
2014-01-01
Objective To compare the differences of diagnostic rates, of the two widely used test positions, in measuring vestibular evoked myogenic potentials (VEMP) and selecting the most appropriate analytical method for diagnostic criteria for the patients with vertigo. Methods Thirty-two patients with vertigo were tested in two comparative testing positions: turning the head to the opposite side of the evaluating side and bowing while in seated position, and bowing while in supine positions. Abnormalities were determined by prolonged latency of p13 or n23, shortening of the interpeak latency, and absence of VEMP formation. Results Using the three criteria above for determining abnormalities, both the seated and supine positions showed no significant differences in diagnostic rates, however, the concordance correlation of the two positions was low. When using only the prolonged latency of p13 or n23 in the two positions, diagnostic rates were not significantly different and their concordance correlation was high. On the other hand, using only the shortened interpeak latency in both positions showed no significant difference of diagnostic rates, and the degree of agreement between two positions was low. Conclusion Bowing while in seated position with the head turned in the opposite direction to the area being evaluated is found to be the best VEMP test position due to the consistent level of sternocleidomastoid muscle tension and the high level of compliance. Also, among other diagnostic analysis methods, using prolonged latency of p13 or n23 as the criterion is found to be the most appropriate method of analysis for the VEMP test. PMID:24855617
Houshmand, Behzad; Janbakhsh, Noushin; Khalilian, Fatemeh; Talebi Ardakani, Mohammad Reza
2017-01-01
Introduction: Diode laser irradiation has recently shown promising results for treatment of gingival pigmentation. This study sought to compare the efficacy of 2 diode laser irradiation protocols for treatment of gingival pigmentations, namely the conventional method and the sieve method. Methods: In this split-mouth clinical trial, 15 patients with gingival pigmentation were selected and their pigmentation intensity was determined using Dummett's oral pigmentation index (DOPI) in different dental regions. Diode laser (980 nm wavelength and 2 W power) was irradiated through a stipple pattern (sieve method) and conventionally in the other side of the mouth. Level of pain and satisfaction with the outcome (both patient and periodontist) were measured using a 0-10 visual analog scale (VAS) for both methods. Patients were followed up at 2 weeks, one month and 3 months. Pigmentation levels were compared using repeated measures of analysis of variance (ANOVA). The difference in level of pain and satisfaction between the 2 groups was analyzed by sample t test and general estimate equation model. Results: No significant differences were found regarding the reduction of pigmentation scores and pain and scores between the 2 groups. The difference in satisfaction with the results at the three time points was significant in both conventional and sieve methods in patients ( P = 0.001) and periodontists ( P = 0.015). Conclusion: Diode laser irradiation in both methods successfully eliminated gingival pigmentations. The sieve method was comparable to conventional technique, offering no additional advantage.
Mincewicz, Grzegorz; Rumiński, Jacek; Krzykowski, Grzegorz
2012-02-01
Recently, we described a model system which included corrections of high-resolution computed tomography (HRCT) bronchial measurements based on the adjusted subpixel method (ASM). To verify the clinical application of ASM by comparing bronchial measurements obtained by means of the traditional eye-driven method, subpixel method alone and ASM in a group comprised of bronchial asthma patients and healthy individuals. The study included 30 bronchial asthma patients and the control group comprised of 20 volunteers with no symptoms of asthma. The lowest internal and external diameters of the bronchial cross-sections (ID and ED) and their derivative parameters were determined in HRCT scans using: (1) traditional eye-driven method, (2) subpixel technique, and (3) ASM. In the case of the eye-driven method, lower ID values along with lower bronchial lumen area and its percentage ratio to total bronchial area were basic parameters that differed between asthma patients and healthy controls. In the case of the subpixel method and ASM, both groups were not significantly different in terms of ID. Significant differences were observed in values of ED and total bronchial area with both parameters being significantly higher in asthma patients. Compared to ASM, the eye-driven method overstated the values of ID and ED by about 30% and 10% respectively, while understating bronchial wall thickness by about 18%. Results obtained in this study suggest that the traditional eye-driven method of HRCT-based measurement of bronchial tree components probably overstates the degree of bronchial patency in asthma patients. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Using the MDCT thick slab MinIP method for the follow-up of pulmonary emphysema.
Lan, Hai; Nishitani, Hiromu; Nishihara, Sadamitsu; Ueno, Junji; Takao, Shoichiro; Iwamoto, Seiji; Kawanaka, Takashi; Mahmut, Mawlan; Qingge, Si
2011-08-01
The purpose of this study was to evaluate the usefulness of thick slab minimum intensity projection (MinIP) as a follow-up method in patients with pulmonary emphysema. This method was used to determine the presence or absence of changes over time in the lung field based on multi-detector-row CT (MDCT) data. Among patients diagnosed with pulmonary emphysema who underwent 16-MDCT (slice thickness, 1 mm) twice at an interval of 6 months or more, 12 patients without changes in the lung field and 14 with clear changes in the lung field were selected as subjects. An image interpretation experiment was performed by five image interpreters. Pulmonary emphysema was followed up using two types of thick slab MinIP (thick slab MinIP 1 and 2) and multi-planar reformation (MPR), and the results of image interpretation were evaluated by receiver operating characteristic (ROC) analysis. In addition, the time required for image interpretation was compared among the three follow-up methods. The area under the ROC curve (Az) was 0.794 for thick slab MinIP 1, 0.778 for the thick slab MinIP 2, and 0.759 for MPR, showing no significant differences among the three methods. Individual differences in each item were significantly more marked for MPR than for thick slab MinIP. The time required for image interpretation was around 18 seconds for thick slab MinIP 1, 11 seconds for thick slab MinIP 2, and approximately 127 seconds for MPR, showing significant differences among the three methods. There were no significant differences in the results of image interpretation regarding the presence or absence of changes in the lung fields between thick slab MinIP and MPR. However, thick slab MinIP showed a shorter image interpretation time and smaller individual differences in the results among image interpreters than MPR, suggesting the usefulness of this method for determining the presence or absence of changes with time in the lung fields of patients with pulmonary emphysema.
Differences in ocular parameters between diurnal and nocturnal raptors.
Beckwith-Cohen, Billie; Horowitz, Igal; Bdolah-Abram, Tali; Lublin, Avishai; Ofri, Ron
2015-01-01
To establish and compare normal ocular parameters between and within diurnal and nocturnal raptor groups. Eighty-eight ophthalmically normal raptors of six nocturnal and 11 diurnal species were studied. Tear production was measured using Schirmer tear test (STT) and phenol red thread test (PRTT), and applanation tonometry was conducted. Ultrasonographic measurements of axial length (AL), mediolateral axis (ML), vitreous body (VB), and pecten length (PL) were recorded, and conjunctival cultures were obtained. A weak correlation (R = 0.312, P = 0.006) was found between PRTT and STT. Tear production was significantly lower in nocturnal species (P < 0.001), but no difference was observed in intraocular pressure (IOP). VB and PL were significantly longer in diurnals (P < 0.001 and P = 0.021, respectively), and no significant difference was observed in AL and ML. When comparing results within these groups, there was a significant difference between most species for all parameters except IOP. Fifty-one percent of the examined raptors were positive for mycology or bacteriology, either on culture or PCR. The most common infectious agent isolated was Staphylococcus spp. Phenol red thread test and STT are both valid methods to measure tear production; however, a separate baseline must be determined for each species using these methods, as the results of one method cannot be extrapolated to the other. Due to significant differences observed within diurnal and nocturnal species, it appears that a more intricate division should be used when comparing these parameters for raptors, and the classification of diurnal or nocturnal holds little significance in the baseline of these data. © 2013 American College of Veterinary Ophthalmologists.
Methods for Synthesizing Findings on Moderation Effects Across Multiple Randomized Trials
Brown, C Hendricks; Sloboda, Zili; Faggiano, Fabrizio; Teasdale, Brent; Keller, Ferdinand; Burkhart, Gregor; Vigna-Taglianti, Federica; Howe, George; Masyn, Katherine; Wang, Wei; Muthén, Bengt; Stephens, Peggy; Grey, Scott; Perrino, Tatiana
2011-01-01
This paper presents new methods for synthesizing results from subgroup and moderation analyses across different randomized trials. We demonstrate that such a synthesis generally results in additional power to detect significant moderation findings above what one would find in a single trial. Three general methods for conducting synthesis analyses are discussed, with two methods, integrative data analysis, and parallel analyses, sharing a large advantage over traditional methods available in meta-analysis. We present a broad class of analytic models to examine moderation effects across trials that can be used to assess their overall effect and explain sources of heterogeneity, and present ways to disentangle differences across trials due to individual differences, contextual level differences, intervention, and trial design. PMID:21360061
Methods for synthesizing findings on moderation effects across multiple randomized trials.
Brown, C Hendricks; Sloboda, Zili; Faggiano, Fabrizio; Teasdale, Brent; Keller, Ferdinand; Burkhart, Gregor; Vigna-Taglianti, Federica; Howe, George; Masyn, Katherine; Wang, Wei; Muthén, Bengt; Stephens, Peggy; Grey, Scott; Perrino, Tatiana
2013-04-01
This paper presents new methods for synthesizing results from subgroup and moderation analyses across different randomized trials. We demonstrate that such a synthesis generally results in additional power to detect significant moderation findings above what one would find in a single trial. Three general methods for conducting synthesis analyses are discussed, with two methods, integrative data analysis and parallel analyses, sharing a large advantage over traditional methods available in meta-analysis. We present a broad class of analytic models to examine moderation effects across trials that can be used to assess their overall effect and explain sources of heterogeneity, and present ways to disentangle differences across trials due to individual differences, contextual level differences, intervention, and trial design.
Khobragade, Sujata; Abas, Adinegara Lutfi; Khobragade, Yadneshwar Sudam
2016-01-01
Learning outcomes after traditional teaching methods were compared with problem-based learning (PBL) among fifth year medical students. Six students participated each in traditional teaching and PBL methods, respectively. Traditional teaching method involved PowerPoint (PPT) presentation and PBL included study on case scenario and discussion. Both methods were effective in improving performance of students. Postteaching, we did not find significant differences in learning outcomes between these two teaching methods. (1) Study was conducted with an intention to find out which method of learning is more effective; traditional or PBL. (2) To assess the level of knowledge and understanding in anemia/zoonotic diseases as against diabetes/hypertension. All the students posted from February 3, 2014, to March 14, 2014, participated in this study. Six students were asked to prepare and present a lecture (PPT) and subsequent week other six students were asked to present PBL. Both groups presented different topics. Since it was a pre- and post-test, same students were taken as control. To maintain uniformity and to avoid bias due cultural diversity, language etc., same questions were administered. After taking verbal consent, all 34 students were given pretest on anemia and zoonotic diseases. Then lecture (PPT) by six students on the same topic was given it followed by posttest questionnaire. Subsequent week pretest was conducted on hypertension and diabetes. Then case scenario presentation and discussion (PBL) was done by different six students followed by posttest. Both the methods were compared. Analysis was done manually and standard error of means and students t -test was used to find out statistical significance. We found statistically significant improvement in performance of students after PPT presentation as well as PBL. Both methods are equally effective. However, Pretest results of students in anemia and zoonotic diseases (Group A) were poor compared to pretest results of students in hypertension and diabetes (Group B). The students who participated in presentation did not influence their performance as they were covering a small part of the topic and there were no differences in their marks compared to other students. We did not find significant differences in outcome after teaching between PBL and traditional methods. Performances of students were poor in anemia and zoonotic diseases which need remedial teaching. Assessment may influence retention ability and performance.
Evaluation of analytical performance of a new high-sensitivity immunoassay for cardiac troponin I.
Masotti, Silvia; Prontera, Concetta; Musetti, Veronica; Storti, Simona; Ndreu, Rudina; Zucchelli, Gian Carlo; Passino, Claudio; Clerico, Aldo
2018-02-23
The study aim was to evaluate and compare the analytical performance of the new chemiluminescent immunoassay for cardiac troponin I (cTnI), called Access hs-TnI using DxI platform, with those of Access AccuTnI+3 method, and high-sensitivity (hs) cTnI method for ARCHITECT platform. The limits of blank (LoB), detection (LoD) and quantitation (LoQ) at 10% and 20% CV were evaluated according to international standardized protocols. For the evaluation of analytical performance and comparison of cTnI results, both heparinized plasma samples, collected from healthy subjects and patients with cardiac diseases, and quality control samples distributed in external quality assessment programs were used. LoB, LoD and LoQ at 20% and 10% CV values of the Access hs-cTnI method were 0.6, 1.3, 2.1 and 5.3 ng/L, respectively. Access hs-cTnI method showed analytical performance significantly better than that of Access AccuTnI+3 method and similar results to those of hs ARCHITECT cTnI method. Moreover, the cTnI concentrations measured with Access hs-cTnI method showed close linear regressions with both Access AccuTnI+3 and ARCHITECT hs-cTnI methods, although there were systematic differences between these methods. There was no difference between cTnI values measured by Access hs-cTnI in heparinized plasma and serum samples, whereas there was a significant difference between cTnI values, respectively measured in EDTA and heparin plasma samples. Access hs-cTnI has analytical sensitivity parameters significantly improved compared to Access AccuTnI+3 method and is similar to those of the high-sensitivity method using ARCHITECT platform.
Comparing the NIOSH Method 5040 to a Diesel Particulate Matter Meter for Elemental Carbon
NASA Astrophysics Data System (ADS)
Ayers, David Matthew
Introduction: The sampling of elemental carbon has been associated with monitoring exposures in the trucking and mining industries. Recently, in the field of engineered nanomaterials, single wall and muti-wall carbon nanotubes (MWCNTs) are being produced in ever increasing quantities. The only approved atmospheric sampling for multi-wall carbon nanotubes in NIOSH Method 5040. These results are accurate but can take up to 30 days for sample results to be received. Objectives: Compare the results of elemental carbon sampling from the NIOSH Method 5040 to a Diesel Particulate Matter (DPM) Meter. Methods: MWCNTs were transferred and weighed between several trays placed on a scale. The NIOSH Method 5040 and DPM sampling train was hung 6 inches above the receiving tray. The transferring and weighing of the MWCNTs created an aerosol containing elemental carbon. Twenty-one total samples using both meters type were collected. Results: The assumptions for a Two-Way ANOVA were violated therefore, Mann-Whitney U Tests and a Kruskal-Wallis Test were performed. The hypotheses for both research questions were rejected. There was a significant difference in the EC concentrations obtained by the NIOSH Method 5040 and the DPM meter. There were also significant differences in elemental carbon level concentrations when sampled using a DPM meter versus a sampling pump based upon the three concentration levels (low, medium and high). Conclusions: The differences in the EC concentrations were statistically significant therefore, the two methods (NIOSH Method 5040 and DPM) are not the same. The NIOSH Method 5040 should continue to be the only authorized method of establishing an EC concentration for MWCNTs until a MWCNT specific method or an instantaneous meter is invented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chajon, Enrique; Dumas, Isabelle; Touleimat, Mahmoud B.Sc.
2007-11-01
Purpose: The purpose of this study was to evaluate the inverse planning simulated annealing (IPSA) software for the optimization of dose distribution in patients with cervix carcinoma treated with MRI-based pulsed-dose rate intracavitary brachytherapy. Methods and Materials: Thirty patients treated with a technique using a customized vaginal mold were selected. Dose-volume parameters obtained using the IPSA method were compared with the classic manual optimization method (MOM). Target volumes and organs at risk were delineated according to the Gynecological Brachytherapy Group/European Society for Therapeutic Radiology and Oncology recommendations. Because the pulsed dose rate program was based on clinical experience with lowmore » dose rate, dwell time values were required to be as homogeneous as possible. To achieve this goal, different modifications of the IPSA program were applied. Results: The first dose distribution calculated by the IPSA algorithm proposed a heterogeneous distribution of dwell time positions. The mean D90, D100, and V100 calculated with both methods did not differ significantly when the constraints were applied. For the bladder, doses calculated at the ICRU reference point derived from the MOM differed significantly from the doses calculated by the IPSA method (mean, 58.4 vs. 55 Gy respectively; p = 0.0001). For the rectum, the doses calculated at the ICRU reference point were also significantly lower with the IPSA method. Conclusions: The inverse planning method provided fast and automatic solutions for the optimization of dose distribution. However, the straightforward use of IPSA generated significant heterogeneity in dwell time values. Caution is therefore recommended in the use of inverse optimization tools with clinical relevance study of new dosimetric rules.« less
Yin, Chaomin; Fan, Xiuzhi; Fan, Zhe; Shi, Defang; Gao, Hong
2018-05-01
Enzymes-microwave-ultrasound assisted extraction (EMUE) method had been used to extract Lentinus edodes polysaccharides (LEPs). The enzymatic temperature, enzymatic pH, microwave power and microwave time were optimized by response surface methodology. The yields, properties and antioxidant activities of LEPs from EMUE and other extraction methods including hot-water extraction, enzymes-assisted extraction, microwave-assisted extraction and ultrasound-assisted extraction were evaluated. The results showed that the highest LEPs yield of 9.38% was achieved with enzymatic temperature of 48°C, enzymatic pH of 5.0, microwave power of 440W and microwave time of 10min, which correlated well with the predicted value of 9.79%. Additionally, LEPs from different extraction methods possessed typical absorption peak of polysaccharides, which meant different extraction methods had no significant effects on type of glycosidic bonds and sugar ring of LEPs. However, SEM images of LEPs from different extraction methods were significantly different. Moreover, the different LEPs all showed antioxidant activities, but LEPs from EMUE showed the highest reducing power when compared to other LEPs. The results indicated LEPs from EMUE can be used as natural antioxidant component in the pharmaceutical and functional food industries. Copyright © 2018 Elsevier B.V. All rights reserved.
Improved sampling and analysis of images in corneal confocal microscopy.
Schaldemose, E L; Fontain, F I; Karlsson, P; Nyengaard, J R
2017-10-01
Corneal confocal microscopy (CCM) is a noninvasive clinical method to analyse and quantify corneal nerve fibres in vivo. Although the CCM technique is in constant progress, there are methodological limitations in terms of sampling of images and objectivity of the nerve quantification. The aim of this study was to present a randomized sampling method of the CCM images and to develop an adjusted area-dependent image analysis. Furthermore, a manual nerve fibre analysis method was compared to a fully automated method. 23 idiopathic small-fibre neuropathy patients were investigated using CCM. Corneal nerve fibre length density (CNFL) and corneal nerve fibre branch density (CNBD) were determined in both a manual and automatic manner. Differences in CNFL and CNBD between (1) the randomized and the most common sampling method, (2) the adjusted and the unadjusted area and (3) the manual and automated quantification method were investigated. The CNFL values were significantly lower when using the randomized sampling method compared to the most common method (p = 0.01). There was not a statistical significant difference in the CNBD values between the randomized and the most common sampling method (p = 0.85). CNFL and CNBD values were increased when using the adjusted area compared to the standard area. Additionally, the study found a significant increase in the CNFL and CNBD values when using the manual method compared to the automatic method (p ≤ 0.001). The study demonstrated a significant difference in the CNFL values between the randomized and common sampling method indicating the importance of clear guidelines for the image sampling. The increase in CNFL and CNBD values when using the adjusted cornea area is not surprising. The observed increases in both CNFL and CNBD values when using the manual method of nerve quantification compared to the automatic method are consistent with earlier findings. This study underlines the importance of improving the analysis of the CCM images in order to obtain more objective corneal nerve fibre measurements. © 2017 The Authors Journal of Microscopy © 2017 Royal Microscopical Society.
Comparison of two preparatory techniques for urine cytology.
Dhundee, J; Rigby, H S
1990-01-01
Two methods of preparation of urine for cytology were compared retrospectively. In method 1 cells in the urine were fixed after the preparation of the smear; in method 2 the cells were fixed before smear preparation. Urine cytology reports were correlated with subsequent histological analysis. The specificities of urine cytology using both methods were high (99%). The sensitivity using method 1 was 87%; using method 2 it was 65%. This difference was significant. The cell preparation technique therefore significantly changes the sensitivity of urine cytology. Cellular fixation after smear preparation is preferable to smear preparation after fixation. PMID:2266176
Comparison of three different sterilization and disinfection methods on orthodontic markers
Omidkhoda, Maryam; Rashed, Roozbeh; Bagheri, Zahra; Ghazvini, Kiarash; Shafaee, Hooman
2016-01-01
Background: Marking pencils which are frequently used in orthodontics may cause microbial contamination. The purpose of this study was to evaluate and compare the effectiveness of three disinfection and sterilization methods (autoclave, glutaraldehyde solution, and Deconex spray) on orthodontic markers. Materials and Methods: One hundred and twenty orthodontic markers were divided into four groups each 30 pencils: One control group and three groups for three different disinfection/sterilization methods. To evaluate the effectiveness of these methods, pencils were initially contaminated by common pathogen by immersing the pencils in a suspension containing 1.5 × 108 CFU/ml organisms. Then, the pencils were subjected to corresponding disinfection/sterilization methods, and the number of remaining microorganisms was calculated and compared with control group. Results: In the control group, the mean number of Escherichia coli was significantly higher than the other two microorganisms (P = 0.01, P = 0.031). However, the mean numbers of Staphylococcus aureus and Candida albicans were not significantly different (P = 0.1). After sterilization with autoclave and glutaraldehyde, no microbial growth was observed, whereas after disinfection with Deconx spray some colonies of microorganisms still could be observed. Conclusion: Autoclaving and glutaraldehyde solution are the best methods for disinfecting orthodontic markers. PMID:26998472
Comparison between Bactec Peds Plus F Broth and Conventional Medium for Vitreous Culture.
Tabatabaei, Seyed Ali; Tabatabaei, Seyed Mehdi; Soleimani, Mohammad; Hejrati, Bahman; Mirshahi, Ahmad; Khadabandeh, Alireza; Ahmadraji, Aliasghar; Valipour, Niloofar
2018-05-10
To evaluate the yield of Bactec Peds Plus F broth for vitreous sample culture in cases with infectious endophthalmitis in comparison to conventional medium. Consecutive cases of clinically suspected endophthalmitis were prospectively enrolled in this study. Cultures of the vitreous sample were performed in both Bactec Peds Plus F broth and conventional mediums. Forty eyes of 40 patients who were clinically suspected of infectious endophthalmitis with different etiologies were enrolled in this study. The positive culture yield was 50% and 35% in Bactec Peds Plus F broth and conventional mediums, respectively (p = 0.07). The result of Bactec group was not significantly different among patients who had a history of intravitreal antibiotic injection (p > 0.05) (Table 2). However, results of the conventional method were significantly negative in the previous intravitreal antibiotic injection group (p = 0.02). There was no correlation between the methods of vitreous sampling in both culture methods. Although the difference between two culture methods was not statistically significant in this study, Bactec Peds Plus F broth showed higher positive culture yield in patients with a history of intravitreal antibiotic injection.
[Study on the effect of different impression methods on the marginal fit of all-ceramic crowns].
Zhan, Lilin; Zeng, Liwei; Chen, Ping; Liao, Lan; Li, Shiyue; Liu, Renying
2015-08-01
To investigate the effect of three different impression methods on the marginal fit of all-ceramic crowns. The three methods include scanning silicone rubber impression, cast models, and direct optical impression. The polymethyl methacrylate (PMMA) material of a mandibular first molar in standard model was prepared with 16 models duplicated. The all-ceramic crowns were prepared using three different impression methods. Accurate impressions were made using silicone rubber, and the cast models were obtained. The PMMA models, silicone rubber impressions, and cast models were scanned, and digital models of three groups were obtained to produce 48 zirconia all-ceramic crowns with computer aided design/computer aided manufacture. The marginal fit of these groups was measured by silicone rubber gap impression. Statistical analysis was performed with SPSS 17.0 software. The marginal fit of direct optical impression groups, silicone rubber impression groups, cast model groups was (69.18±9.47), (81.04±10.88), (84.42±9.96) µm. A significant difference was observed in the marginal fit of the direct optical impression groups and the other groups (P<0.05). No statistically significant difference was observed in the marginal fit of the silicone rubber impression groups and the cast model groups (P>0.05). All marginal measurement sites are clinically acceptable by the three different impression scanning methods. The silicone rubber impression scanning method can be used for all-ceramic restorations.
Effect of a novel sterilization method on biomechanical properties of soft tissue allografts.
Baldini, T; Caperton, K; Hawkins, M; McCarty, E
2016-12-01
Evaluate allograft tissue commonly used in soft tissue reconstruction to determine whether stiffness and strength were significantly altered after grafts were treated with different sterilization methods. Unprocessed, irradiated, and grafts treated with supercritical CO 2 were compared. Thirty-eight anterior or posterior tibialis tendons were obtained from a tissue bank (Allograft Innovations, Gainesville, FL). Group I was unprocessed, group II was sterilized with gamma irradiation (20-28 kGy), and group III was sterilized with supercritical CO 2 . The grafts were pretensioned to 89 N for 300 s. Specimens were then loaded from 50 to 300 N at 0.5 Hz for 250 cycles before being loaded to failure at 50 mm/min. Dependent variables were compared between sterilization groups with one-way ANOVA (P < 0.05) and equivalence trial. There was no significant difference in load to failure or failure stress among groups I, II, and III. Group III resulted in 27-36 % lower stiffness than group I and II. This difference was significant at 1, 10, 50, 100, and 250 cycles. There was no significant difference in stiffness between group I and group II. The two sterilization methods tested in this study do not affect allograft strength. The supercritical CO 2 sterilization method resulted in significantly lower stiffness than unprocessed and irradiated allografts. However, the stiffness and strength of all groups tested were greater than that of published values of the native intact anterior cruciate ligament (ACL). This study provides previously unpublished mechanical test data on a new sterilization technique that will assist surgeons to decide which allograft to use in ACL reconstruction surgery. III.
Shahgholian, Nahid; Jazi, Shahrzad Khojandi; Karimian, Jahangir; Valiani, Mahboubeh
2016-01-01
Restless leg syndrome prevalence is high among the patients undergoing hemodialysis. Due to several side effects of medicational treatments, the patients prefer non-medicational methods. Therefore, the present study aimed to investigate the effects of two methods of reflexology and stretching exercises on the severity of restless leg syndrome among patients undergoing hemodialysis. This study is a randomized clinical trial that was done on 90 qualified patients undergoing hemodialysis in selected hospitals of Isfahan, who were diagnosed with restless leg syndrome through standard restless leg syndrome questionnaire. They were randomly assigned by random number table to three groups: Reflexology, stretching exercises, and control groups through random allocation. Foot reflexology and stretching exercises were conducted three times a week for 30-40 min within straight 4 weeks. Data analysis was performed by SPSS version 18 using descriptive and inferential statistical analyses [one-way analysis of variance (ANOVA), paired t-test, and least significant difference (LSD) post hoc test]. There was a significant difference in the mean scores of restless leg syndrome severity between reflexology and stretching exercises groups, compared to control (P < 0.001), but there was no significant difference between the two study groups (P < 0.001). Changes in the mean score of restless leg syndrome severity were significantly higher in reflexology and stretching exercises groups compared to the control group (P < 0.001), but it showed no significant difference between reflexology massage and stretching exercises groups. Our obtained results showed that reflexology and stretching exercises can reduce the severity of restless leg syndrome. These two methods of treatment are recommended to the patients.
Construct and Compare Gene Coexpression Networks with DAPfinder and DAPview.
Skinner, Jeff; Kotliarov, Yuri; Varma, Sudhir; Mine, Karina L; Yambartsev, Anatoly; Simon, Richard; Huyen, Yentram; Morgun, Andrey
2011-07-14
DAPfinder and DAPview are novel BRB-ArrayTools plug-ins to construct gene coexpression networks and identify significant differences in pairwise gene-gene coexpression between two phenotypes. Each significant difference in gene-gene association represents a Differentially Associated Pair (DAP). Our tools include several choices of filtering methods, gene-gene association metrics, statistical testing methods and multiple comparison adjustments. Network results are easily displayed in Cytoscape. Analyses of glioma experiments and microarray simulations demonstrate the utility of these tools. DAPfinder is a new friendly-user tool for reconstruction and comparison of biological networks.
Westgard, Sten A
2016-06-01
To assess the analytical performance of instruments and methods through external quality assessment and proficiency testing data on the Sigma scale. A representative report from five different EQA/PT programs around the world (2 US, 1 Canadian, 1 UK, and 1 Australasian) was accessed. The instrument group standard deviations were used as surrogate estimates of instrument imprecision. Performance specifications from the US CLIA proficiency testing criteria were used to establish a common quality goal. Then Sigma-metrics were calculated to grade the analytical performance. Different methods have different Sigma-metrics for each analyte reviewed. Summary Sigma-metrics estimate the percentage of the chemistry analytes that are expected to perform above Five Sigma, which is where optimized QC design can be implemented. The range of performance varies from 37% to 88%, exhibiting significant differentiation between instruments and manufacturers. Median Sigmas for the different manufacturers in three analytes (albumin, glucose, sodium) showed significant differentiation. Chemistry tests are not commodities. Quality varies significantly from manufacturer to manufacturer, instrument to instrument, and method to method. The Sigma-assessments from multiple EQA/PT programs provide more insight into the performance of methods and instruments than any single program by itself. It is possible to produce a ranking of performance by manufacturer, instrument and individual method. Laboratories seeking optimal instrumentation would do well to consult this data as part of their decision-making process. To confirm that these assessments are stable and reliable, a longer term study should be conducted that examines more results over a longer time period. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Detection of circulating tumor cells using oHSV1-hTERT-GFP in lung cancer.
Gao, Hongjun; Liu, Wenjing; Yang, Shaoxing; Zhang, Wen; Li, Xiaoyan; Qin, Haifeng; Wang, Weixia; Zhao, Changyun
2018-01-01
This study was conducted to evaluate the clinical utility of the oHSV1-hTERT-GFP circulating tumor cell (CTC) detection method in the peripheral blood of patients with lung cancer by comparing its sensitivity to the CellSearch CTC detection method. The oHSV1-hTERT-GFP and CellSearch CTC detection methods were compared using peripheral blood samples of patients pathologically diagnosed with lung cancer. A total of 240 patients with lung cancer were recruited, including 89 patients who were newly diagnosed and 151 patients who had previously received treatment. Sixty-six newly diagnosed patients were evaluated using both methods. The CTC detection rates were 71.2% and 33.3% using the oHSV1-hTERT-GFP and CellSearch methods, respectively; this difference was statistically significant (P = 0.000). Among the entire cohort (n = 240), the CTC detection rate using the oHSV1-hTERT-GFP method was 76.3%, with a CTC count of 0-81. The CTC detection rates were 76.7%, 68.9%, and 76.3% in patients with squamous cell carcinoma, adenocarcinoma, and small cell lung cancer, respectively. There was no statistically significant difference in the CTC detection rates between these different pathological subtypes (P = 0.738). The CTC detection rates of 79.8% and 74.4% in patients with stage I-III and IV lung cancer, respectively, were not significantly different (P = 0.427). The oHSV1-hTERT-GFP method is highly effective for detecting CTCs in patients with lung cancer, independent of pathological type and disease stage, and is ideal for large-scale clinical applications. © 2017 The Authors. Thoracic Cancer published by China Lung Oncology Group and John Wiley & Sons Australia, Ltd.
Comparison of Manual Refraction Versus Autorefraction in 60 Diabetic Retinopathy Patients.
Shirzadi, Keyvan; Shahraki, Kourosh; Yahaghi, Emad; Makateb, Ali; Khosravifard, Keivan
2016-07-27
The purpose of the study was to evaluate the comparison of manual refraction versus autorefraction in diabetic retinopathy patients. The study was conducted at the Be'sat Army Hospital from 2013-2015. In the present study differences between two common refractometry methods (manual refractometry and Auto refractometry) in diagnosis and follow up of retinopathy in patients affected with diabetes is investigated. Our results showed that there is a significant difference in visual acuity score of patients between manual and auto refractometry. Despite this fact, spherical equivalent scores of two methods of refractometry did not show a significant statistical difference in the patients. Although use of manual refraction is comparable with autorefraction in evaluating spherical equivalent scores in diabetic patients affected with retinopathy, but in the case of visual acuity results from these two methods are not comparable.
Engagement Assessment Using EEG Signals
NASA Technical Reports Server (NTRS)
Li, Feng; Li, Jiang; McKenzie, Frederic; Zhang, Guangfan; Wang, Wei; Pepe, Aaron; Xu, Roger; Schnell, Thomas; Anderson, Nick; Heitkamp, Dean
2012-01-01
In this paper, we present methods to analyze and improve an EEG-based engagement assessment approach, consisting of data preprocessing, feature extraction and engagement state classification. During data preprocessing, spikes, baseline drift and saturation caused by recording devices in EEG signals are identified and eliminated, and a wavelet based method is utilized to remove ocular and muscular artifacts in the EEG recordings. In feature extraction, power spectrum densities with 1 Hz bin are calculated as features, and these features are analyzed using the Fisher score and the one way ANOVA method. In the classification step, a committee classifier is trained based on the extracted features to assess engagement status. Finally, experiment results showed that there exist significant differences in the extracted features among different subjects, and we have implemented a feature normalization procedure to mitigate the differences and significantly improved the engagement assessment performance.
Dental enamel defect diagnosis through different technology-based devices.
Kobayashi, Tatiana Yuriko; Vitor, Luciana Lourenço Ribeiro; Carrara, Cleide Felício Carvalho; Silva, Thiago Cruvinel; Rios, Daniela; Machado, Maria Aparecida Andrade Moreira; Oliveira, Thais Marchini
2018-06-01
Dental enamel defects (DEDs) are faulty or deficient enamel formations of primary and permanent teeth. Changes during tooth development result in hypoplasia (a quantitative defect) and/or hypomineralisation (a qualitative defect). To compare technology-based diagnostic methods for detecting DEDs. Two-hundred and nine dental surfaces of anterior permanent teeth were selected in patients, 6-11 years of age, with cleft lip with/without cleft palate. First, a conventional clinical examination was conducted according to the modified Developmental Defects of Enamel Index (DDE Index). Dental surfaces were evaluated using an operating microscope and a fluorescence-based device. Interexaminer reproducibility was determined using the kappa test. To compare groups, McNemar's test was used. Cramer's V test was used for comparing the distribution of index codes obtained after classification of all dental surfaces. Cramer's V test revealed statistically significant differences (P < .0001) in the distribution of index codes obtained using the different methods; the coefficients were 0.365 for conventional clinical examination versus fluorescence, 0.961 for conventional clinical examination versus operating microscope and 0.358 for operating microscope versus fluorescence. The sensitivity of the operating microscope and fluorescence method was statistically significant (P = .008 and P < .0001, respectively). Otherwise, the results did not show statistically significant differences in accuracy and specificity for either the operating microscope or the fluorescence methods. This study suggests that the operating microscope performed better than the fluorescence-based device and could be an auxiliary method for the detection of DEDs. © 2017 FDI World Dental Federation.
Lee, Wan-Sun; Kim, Woong-Chul
2015-01-01
PURPOSE To assess the marginal and internal gaps of the copings fabricated by computer-aided milling and direct metal laser sintering (DMLS) systems in comparison to casting method. MATERIALS AND METHODS Ten metal copings were fabricated by casting, computer-aided milling, and DMLS. Seven mesiodistal and labiolingual positions were then measured, and each of these were divided into the categories; marginal gap (MG), cervical gap (CG), axial wall at internal gap (AG), and incisal edge at internal gap (IG). Evaluation was performed by a silicone replica technique. A digital microscope was used for measurement of silicone layer. Statistical analyses included one-way and repeated measure ANOVA to test the difference between the fabrication methods and categories of measured points (α=.05), respectively. RESULTS The mean gap differed significantly with fabrication methods (P<.001). Casting produced the narrowest gap in each of the four measured positions, whereas CG, AG, and IG proved narrower in computer-aided milling than in DMLS. Thus, with the exception of MG, all positions exhibited a significant difference between computer-aided milling and DMLS (P<.05). CONCLUSION Although the gap was found to vary with fabrication methods, the marginal and internal gaps of the copings fabricated by computer-aided milling and DMLS fell within the range of clinical acceptance (<120 µm). However, the statistically significant difference to conventional casting indicates that the gaps in computer-aided milling and DMLS fabricated restorations still need to be further reduced. PMID:25932310
Uchiyama, Yuta; Mori, Koichiro
2017-08-15
The purpose of this paper is to analyze how different definitions and methods for delineating the spatial boundaries of cities have an impact on the values of city sustainability indicators. It is necessary to distinguish the inside of cities from the outside when calculating the values of sustainability indicators that assess the impacts of human activities within cities on areas beyond their boundaries. For this purpose, spatial boundaries of cities should be practically detected on the basis of a relevant definition of a city. Although no definition of a city is commonly shared among academic fields, three practical methods for identifying urban areas are available in remote sensing science. Those practical methods are based on population density, landcover, and night-time lights. These methods are correlated, but non-negligible differences exist in their determination of urban extents and urban population. Furthermore, critical and statistically significant differences in some urban environmental sustainability indicators result from the three different urban detection methods. For example, the average values of CO 2 emissions per capita and PM 10 concentration in cities with more than 1 million residents are significantly different among the definitions. When analyzing city sustainability indicators and disseminating the implication of the results, the values based on the different definitions should be simultaneously investigated. It is necessary to carefully choose a relevant definition to analyze sustainability indicators for policy making. Otherwise, ineffective and inefficient policies will be developed. Copyright © 2017 Elsevier B.V. All rights reserved.
2011-01-01
Background Accidental hypothermia increases mortality and morbidity in trauma patients. Various methods for insulating and wrapping hypothermic patients are used worldwide. The aim of this study was to compare the thermal insulating effects and comfort of bubble wrap, ambulance blankets / quilts, and Hibler's method, a low-cost method combining a plastic outer layer with an insulating layer. Methods Eight volunteers were dressed in moistened clothing, exposed to a cold and windy environment then wrapped using one of the three different insulation methods in random order on three different days. They were rested quietly on their back for 60 minutes in a cold climatic chamber. Skin temperature, rectal temperature, oxygen consumption were measured, and metabolic heat production was calculated. A questionnaire was used for a subjective evaluation of comfort, thermal sensation, and shivering. Results Skin temperature was significantly higher 15 minutes after wrapping using Hibler's method compared with wrapping with ambulance blankets / quilts or bubble wrap. There were no differences in core temperature between the three insulating methods. The subjects reported more shivering, they felt colder, were more uncomfortable, and had an increased heat production when using bubble wrap compared with the other two methods. Hibler's method was the volunteers preferred method for preventing hypothermia. Bubble wrap was the least effective insulating method, and seemed to require significantly higher heat production to compensate for increased heat loss. Conclusions This study demonstrated that a combination of vapour tight layer and an additional dry insulating layer (Hibler's method) is the most efficient wrapping method to prevent heat loss, as shown by increased skin temperatures, lower metabolic rate and better thermal comfort. This should then be the method of choice when wrapping a wet patient at risk of developing hypothermia in prehospital environments. PMID:21699720
Learning physics: A comparative analysis between instructional design methods
NASA Astrophysics Data System (ADS)
Mathew, Easow
The purpose of this research was to determine if there were differences in academic performance between students who participated in traditional versus collaborative problem-based learning (PBL) instructional design approaches to physics curricula. This study utilized a quantitative quasi-experimental design methodology to determine the significance of differences in pre- and posttest introductory physics exam performance between students who participated in traditional (i.e., control group) versus collaborative problem solving (PBL) instructional design (i.e., experimental group) approaches to physics curricula over a college semester in 2008. There were 42 student participants (N = 42) enrolled in an introductory physics course at the research site in the Spring 2008 semester who agreed to participate in this study after reading and signing informed consent documents. A total of 22 participants were assigned to the experimental group (n = 22) who participated in a PBL based teaching methodology along with traditional lecture methods. The other 20 students were assigned to the control group (n = 20) who participated in the traditional lecture teaching methodology. Both the courses were taught by experienced professors who have qualifications at the doctoral level. The results indicated statistically significant differences (p < .01) in academic performance between students who participated in traditional (i.e., lower physics posttest scores and lower differences between pre- and posttest scores) versus collaborative (i.e., higher physics posttest scores, and higher differences between pre- and posttest scores) instructional design approaches to physics curricula. Despite some slight differences in control group and experimental group demographic characteristics (gender, ethnicity, and age) there were statistically significant (p = .04) differences between female average academic improvement which was much higher than male average academic improvement (˜63%) in the control group which may indicate that traditional teaching methods are more effective in females, whereas there was no significant difference noted in the experimental group between male and female participants. There was a statistically significant and negative relationship (r = -.61, p = .01) between age and physics pretest scores in the control group. No statistical analyses yielded significantly different average academic performance values in either group as delineated by ethnicity.
Goo, Hyun Woo; Park, Sang-Hyub
2015-12-01
To assess agreement between two semi-automatic, three-dimensional (3D) computed tomography (CT) ventricular volumetry methods with different user interactions in patients with congenital heart disease. In 30 patients with congenital heart disease (median age 8 years, range 5 days-33 years; 20 men), dual-source, multi-section, electrocardiography-synchronized cardiac CT was obtained at the end-systolic (n = 22) and/or end-diastolic (n = 28) phase. Nineteen left ventricle end-systolic (LV ESV), 28 left ventricle end-diastolic (LV EDV), 22 right ventricle end-systolic (RV ESV), and 28 right ventricle end-diastolic volumes (RV EDV) were successfully calculated using two semi-automatic, 3D segmentation methods with different user interactions (high in method 1, low in method 2). The calculated ventricular volumes of the two methods were compared and correlated. A P value <0.05 was considered statistically significant. LV ESV (35.95 ± 23.49 ml), LV EDV (88.76 ± 61.83 ml), and RV ESV (46.87 ± 47.39 ml) measured by method 2 were slightly but significantly smaller than those measured by method 1 (41.25 ± 26.94 ml, 92.20 ± 62.69 ml, 53.61 ± 50.08 ml for LV ESV, LV EDV, and RV ESV, respectively; P ≤ 0.02). In contrast, no statistically significant difference in RV EDV (122.57 ± 88.57 ml in method 1, 123.83 ± 89.89 ml in method 2; P = 0.36) was found between the two methods. All ventricular volumes showed very high correlation (R = 0.978, 0.993, 0.985, 0.997 for LV ESV, LV EDV, RV ESV, and RV EDV, respectively; P < 0.001) between the two methods. In patients with congenital heart disease, 3D CT ventricular volumetry shows good agreement and high correlation between the two methods, but method 2 tends to slightly underestimate LV ESV, LV EDV, and RV ESV.
Measurement of temperature induced in bone during drilling in minimally invasive foot surgery.
Omar, Noor Azzizah; McKinley, John C
2018-02-19
There has been growing interest in minimally invasive foot surgery due to the benefits it delivers in post-operative outcomes in comparison to conventional open methods of surgery. One of the major factors determining the protocol in minimally invasive surgery is to prevent iatrogenic thermal osteonecrosis. The aim of the study is to look at various drilling parameters in a minimally invasive surgery setting that would reduce the risk of iatrogenic thermal osteonecrosis. Sixteen fresh-frozen tarsal bones and two metatarsal bones were retrieved from three individuals and drilled using various settings. The parameters considered were drilling speed, drill diameter, and inter-individual cortical variability. Temperature measurements of heat generated at the drilling site were collected using two methods; thermocouple probe and infrared thermography. The data obtained were quantitatively analysed. There was a significant difference in the temperatures generated with different drilling speeds (p<0.05). However, there was no significant difference in temperatures recorded between the bones of different individuals and in bones drilled using different drill diameters. Thermocouple showed significantly more sensitive tool in measuring temperature compared to infrared thermography. Drilling at an optimal speed significantly reduced the risk of iatrogenic thermal osteonecrosis by maintaining temperature below the threshold level. Although different drilling diameters did not produce significant differences in temperature generation, there is a need for further study on the mechanical impact of using different drill diameters. Copyright © 2018 Elsevier Ltd. All rights reserved.
Ramezani-Fard, Ehsan; Romano, Nicholas; Goh, Yong-Meng; Oskoueian, Ehsan; Ehteshami, Fariborz; Ebrahimi, Mahdi
2016-07-01
Tilapia farmers are increasingly relying on dietary fish oil alternatives which substantially reduces health beneficial n-3 polyunsaturated fatty acids (PUFA) in tilapia products.? This may be further exacerbated depending on the cooking method.? This study aimed to evaluate the effects of different cooking methods on the fatty acid composition and oxidative stability of tilapia minced meat after prior fish oil fortifications with or without clove essential oil. Results showed that frying tilapia in either sunflower or palm oil significantly increased the saturated fatty acid and linoleic acid content, respectively, of tilapia. However, fish oil fortifications significantly increased the n-3 PUFA content, but tended to decrease oxidative stability, particularly when microwaving. This was mitigated by clove essential oil, which significantly improved oxidative stability after cooking. Results indicate that n-3 PUFA and clove essential oil fortifications is an effective method to deliver and protect these beneficial fatty acids for human consumers. ?
Sá, Marcos A.; Neto, Gabriel R.; Costa, Pablo B.; Gomes, Thiago M.; Bentes, Cláudio M.; Brown, Amanda F.; Novaes, Jefferson S.
2015-01-01
This study aimed to investigate the acute effects of passive static and ballistic stretching on maximal repetition performance during a resistance training session (RTS). Nine male subjects underwent three experimental conditions: ballistic stretching (BS); passive static stretching (PSS); and a specific warm-up (SW). The RTS was composed of three sets of 12RM for the following exercises: leg press 45 (LP), leg extension (LE), leg curl (LC), and plantar flexors (PF). Performance of six sessions was assessed 48 hours apart. The first visit consisted of a familiarization session including stretching methods and exercises used in the RTS. On the second and third visit, a strength test and retest were performed. During the fourth to the sixth visit, the volunteers randomly performed the following protocols: BS+RTS; PSS+RTS; or SW+RTS. For the sum of the RM number of each three-set exercise, significant differences were found between PSS vs. SW for the LP (p = 0.001); LE (p = 0.005); MF (p = 0.001); and PF (p = 0.038). For the comparison between the methods of stretching PSS vs. BS, significant differences were found only for the FP (p = 0.019). When analyzing the method of stretching BS vs. SW, significant differences were found for the LP (p = 0.014) and MF (p = 0.002). For the total sum of the RM number of three sets of the four exercises that composed the RTS, significant differences were observed (p < 0.05) in the following comparisons: PPS vs. SW (p = 0.001), PPS vs. BS (p = 0.008), and BS vs. SW (p = 0.002). Accordingly, the methods of passive static and ballistic stretching should not be recommended before a RTS. PMID:25964821
Neck Muscle Moment Arms Obtained In-Vivo from MRI: Effect of Curved and Straight Modeled Paths.
Suderman, Bethany L; Vasavada, Anita N
2017-08-01
Musculoskeletal models of the cervical spine commonly represent neck muscles with straight paths. However, straight lines do not best represent the natural curvature of muscle paths in the neck, because the paths are constrained by bone and soft tissue. The purpose of this study was to estimate moment arms of curved and straight neck muscle paths using different moment arm calculation methods: tendon excursion, geometric, and effective torque. Curved and straight muscle paths were defined for two subject-specific cervical spine models derived from in vivo magnetic resonance images (MRI). Modeling neck muscle paths with curvature provides significantly different moment arm estimates than straight paths for 10 of 15 neck muscles (p < 0.05, repeated measures two-way ANOVA). Moment arm estimates were also found to be significantly different among moment arm calculation methods for 11 of 15 neck muscles (p < 0.05, repeated measures two-way ANOVA). In particular, using straight lines to model muscle paths can lead to overestimating neck extension moment. However, moment arm methods for curved paths should be investigated further, as different methods of calculating moment arm can provide different estimates.
A New Method for Obtaining Russell-Saunders Terms
ERIC Educational Resources Information Center
Liu, Ying; Liu, Yue; Liu, Bihui
2011-01-01
A new method for obtaining Russell-Saunders terms of atomic configurations is reported. This new method is significantly different from, while at the same time complementary to, previously published methods for obtaining atomic terms. This novel procedure is elicited by the method used to determine the splitting of S, P, D terms in weak ligand…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rowe, M.D.; Pierce, B.L.
This report presents results of tests of different final site selection methods used for siting large-scale facilities such as nuclear power plants. Test data are adapted from a nuclear power plant siting study conducted on Long Island, New York. The purpose of the tests is to determine whether or not different final site selection methods produce different results, and to obtain some understanding of the nature of any differences found. Decision rules and weighting methods are included. Decision rules tested are Weighting Summation, Power Law, Decision Analysis, Goal Programming, and Goal Attainment; weighting methods tested are Categorization, Ranking, Rating Ratiomore » Estimation, Metfessel Allocation, Indifferent Tradeoff, Decision Analysis lottery, and Global Evaluation. Results show that different methods can, indeed, produce different results, but that the probability that they will do so is controlled by the structure of differences among the sites being evaluated. Differences in weights and suitability scores attributable to methods have reduced significance if the alternatives include one or two sites that are superior to all others in many attributes. The more tradeoffs there are among good and bad levels of different attributes at different sites, the more important are the specifics of methods to the final decision. 5 refs., 14 figs., 19 tabs.« less
The impact of eating methods on eating rate and glycemic response in healthy adults.
Sun, Lijuan; Ranawana, Dinesh Viren; Tan, Wei Jie Kevin; Quek, Yu Chin Rina; Henry, Christiani Jeyakumar
2015-02-01
Singapore is an island state that is composed of three major ethnic groups, namely Chinese, Malay and Indian. Its inhabitants consume food either using chopsticks (Chinese), fingers (Malay and Indian) or spoon (Chinese, Malay and Indian). Previous work by our group showed that the degree of mastication significantly influenced the glycemic response. The degree of mastication in turn may depend on the eating method as the amount of food taken per mouthful and chewing time differs between eating methods. Eleven healthy volunteers came in on six non-consecutive days to the laboratory and evaluated three methods of eating white rice (spoon, chopsticks and fingers) once and the reference food (glucose solution) three times in a random order. Their glycemic response (GR) was measured for the subsequent 120 min. Mastication parameters were determined using surface electrode electromyography. The GR to white rice eating with chopsticks was significantly lower than spoon. The GI of eating rice with chopsticks was 68 which is significantly lower than eating with spoon (GI=81). However there were no differences between fingers and spoon, and between fingers and chopsticks either in GR 120 min or GI. The inter-individual number of mouthful, number of chews per mouthful, chewing time per mouthful and the total time taken to consume the whole portion of rice were significantly different between spoon and chopsticks groups. Significant correlations between the number of mouthful to take the entire portion of rice and amount of rice per mouthful during mastication and the GR were observed for eating rice with spoon and chopsticks, but not for fingers. The results suggest that individual differences in number of mouthful and amount of rice per mouthful may be two of the causes for inter-individual differences in the GR between spoon and chopsticks. The present study suggests that eating rice with different feeding tools has different chewing times and amount of food taken per mouthful and then alters the GI of the rice. Copyright © 2014 Elsevier Inc. All rights reserved.
Fernandes, Marcelo José; Ruta, Danny Adolph; Ogden, Graham Richard; Pitts, Nigel Berry; Ogston, Simon Alexander
2006-02-01
To validate the Oral Health Impact Profile (OHIP)-14 in a sample of patients attending general dental practice. Patients with pathology-free impacted wisdom teeth were recruited from six general dental practices in Tayside, Scotland, and followed for a year to assess the development of problems related to impaction. The OHIP-14 was completed at baseline and at 1-year follow-up, and analysed using three different scoring methods: a summary score, a weighted and standardized score and the total number of problems reported. Instrument reliability was measured by assessing internal consistency and test-retest reliability. Construct validity was assessed using a number of variables. Linear regression was then used to model the relationship between OHIP-14 and all significantly correlated variables. Responsiveness was measured using the standardized response mean (SRM). Adjusted R(2)s and SRMs were calculated for each of the three scoring methods. Estimates for the differences between adjusted R(2)s and the differences between SRMs were obtained with 95% confidence intervals. A total of 278 and 169 patients completed the questionnaire at baseline and follow-up, respectively. Reliability - Cronbach's alpha coefficients ranged from 0.30 to 0.75. Alpha coefficients for all 14 items were 0.88 and 0.87 for baseline and follow-up, respectively. Test-retest coefficients ranged from 0.72 to 0.78. Validity - OHIP-14 scores were significantly correlated with number of teeth, education, main activity, the use of mouthwash, frequency of seeing a dentist, the reason for the last dental appointment, smoking, alcohol intake, pain and symptoms. Adjusted R(2)s ranged from 0.123 to 0.202 and there were no statistically significant differences between those for the three different scoring methods. Responsiveness - The SRMs ranged from 0.37 to 0.56 and there was a statistically significant difference between the summary scores method and the total number of problems method for symptomatic patients. The OHIP-14 is a valid and reliable measure of oral health-related quality of life in general dental practice and is responsive to third molar clinical change. The summary score method demonstrated performance as good as, or better than, the other methods studied.
Kandel, Ramkrishna; Chen, Charles Y.; Grau, Craig R.; Dorrance, Ann E.; Liu, Jean Q.; Wang, Yang; Wang, Dechun
2018-01-01
Soybean (Glycine max L. Merr.) white mold (SWM), caused by Sclerotinia sclerotiorum (Lib) de Barry), is a devastating fungal disease in the Upper Midwest of the United States and southern Canada. Various methods exist to evaluate for SWM resistance and many quantitative trait loci (QTL) with minor effect governing SWM resistance have been identified in prior studies. This study aimed to predict field resistance to SWM using low-cost and efficient greenhouse inoculation methods and to confirm the QTL reported in previous studies. Three related but independent studies were conducted in the field, greenhouse, and laboratory to evaluate for SWM resistance. The first study evaluated 66 soybean plant introductions (PIs) with known field resistance to SWM using the greenhouse drop-mycelium inoculation method. These 66 PIs were significantly (P < 0.043) different for resistance to SWM. However, year was highly significant (P < 0.00001), while PI x year interaction was not significant (P < 0.623). The second study compared plant mortality (PM) of 35 soybean breeding lines or varieties in greenhouse inoculation methods with disease severity index (DSI) in field evaluations. Moderate correlation (r) between PM under drop-mycelium method and DSI in field trials (r = 0.65, p < 0.0001) was obtained. The PM under spray-mycelium was also correlated significantly with DSI from field trials (r = 0.51, p < 0.0018). Likewise, significant correlation (r = 0.62, p < 0.0001) was obtained between PM across greenhouse inoculation methods and DSI across field trials. These findings suggest that greenhouse inoculation methods could predict the field resistance to SWM. The third study attempted to validate 33 QTL reported in prior studies using seven populations that comprised a total of 392 F4 : 6 lines derived from crosses involving a partially resistant cultivar “Skylla,” five partially resistant PIs, and a known susceptible cultivar “E00290.” The estimates of broad-sense heritability (h2) ranged from 0.39 to 0.66 in the populations. Of the seven populations, four had h2 estimates that were significantly different from zero (p < 0.05). Single marker analysis across populations and inoculation methods identified 11 significant SSRs (p < 0.05) corresponding to 10 QTL identified by prior studies. Thus, these five new PIs could be used as new sources of resistant alleles to develop SWM resistant commercial cultivars. PMID:29731761
Wolever, Thomas M S
2004-02-01
To evaluate the suitability for glycaemic index (GI) calculations of using blood sampling schedules and methods of calculating area under the curve (AUC) different from those recommended, the GI values of five foods were determined by recommended methods (capillary blood glucose measured seven times over 2.0 h) in forty-seven normal subjects and different calculations performed on the same data set. The AUC was calculated in four ways: incremental AUC (iAUC; recommended method), iAUC above the minimum blood glucose value (AUCmin), net AUC (netAUC) and iAUC including area only before the glycaemic response curve cuts the baseline (AUCcut). In addition, iAUC was calculated using four different sets of less than seven blood samples. GI values were derived using each AUC calculation. The mean GI values of the foods varied significantly according to the method of calculating GI. The standard deviation of GI values calculating using iAUC (20.4), was lower than six of the seven other methods, and significantly less (P<0.05) than that using netAUC (24.0). To be a valid index of food glycaemic response independent of subject characteristics, GI values in subjects should not be related to their AUC after oral glucose. However, calculating GI using AUCmin or less than seven blood samples resulted in significant (P<0.05) relationships between GI and mean AUC. It is concluded that, in subjects without diabetes, the recommended blood sampling schedule and method of AUC calculation yields more valid and/or more precise GI values than the seven other methods tested here. The only method whose results agreed reasonably well with the recommended method (ie. within +/-5 %) was AUCcut.
Patrick, T E; Goodwin, T L; Collins, J A; Wyche, R C; Love, B E
1972-04-01
A comparison of two types of scalders was conducted to determine their effectiveness in reducing bacterial contamination of poultry carcasses. A conventional hot-water scalder and a prototype model of a steam scalder were tested under commercial conditions. Total plate counts from steam-scalded birds were significantly lower than the counts of water-scalded birds immediately after scalding and again after picking. No differences in the two methods could be found after chilling. Coliform counts from steam-scalded birds were significantly lower than the counts from water-scalded birds immediately after scalding. No significant differences in coliform counts were detected when the two scald methods were compared after defeathering and chilling.
The Adams formulas for numerical integration of differential equations from 1st to 20th order
NASA Technical Reports Server (NTRS)
Kirkpatrick, J. C.
1976-01-01
The Adams Bashforth predictor coefficients and the Adams Moulton corrector coefficients for the integration of differential equations are presented for methods of 1st to 20th order. The order of the method as presented refers to the highest order difference formula used in Newton's backward difference interpolation formula, on which the Adams method is based. The Adams method is a polynomial approximation method derived from Newton's backward difference interpolation formula. The Newton formula is derived and expanded to 20th order. The Adams predictor and corrector formulas are derived and expressed in terms of differences of the derivatives, as well as in terms of the derivatives themselves. All coefficients are given to 18 significant digits. For the difference formula only, the ratio coefficients are given to 10th order.
1984-03-01
difference calcula- tion, would result in erroneously lower productivity ratios. Only two topics are not adequately addressed with the method --the first...for determination of this term. 3. CAIDQS P.22li y §easuI~gZ._ Jelbo The next method differs significantly from the previous two in that it deals with...Chasen’s Method (as applied by Lonq Beach M.S.) . . . . . . . o . o . . . . . 31 2. Shah G Yans Method . . . . . . . . . . . 34 3. CARDOS Productivity
ERIC Educational Resources Information Center
Leenaars, Antoon A.; Lester, David
1989-01-01
Compared suicide notes of individuals using active and passive methods for suicide for presence of 50 classifications regarding psychodynamics of perturbation, lethality, relations, self-cognitions, etc. Two sets of notes resembled each other closely, only difference being that active group more often cited rejection by significant other as…
Wagner, David G; Russell, Donna K; Benson, Jenna M; Schneider, Ashley E; Hoda, Rana S; Bonfiglio, Thomas A
2011-10-01
Traditional cell block (TCB) sections serve as an important diagnostic adjunct to cytologic smears but are also used today as a reliable preparation for immunohistochemical (IHC) studies. There are many ways to prepare a cell block and the methods continue to be revised. In this study, we compare the TCB with the Cellient™ automated cell block system. Thirty-five cell blocks were obtained from 16 benign and 19 malignant nongynecologic cytology specimens at a large university teaching hospital and prepared according to TCB and Cellient protocols. Cell block sections from both methods were compared for possible differences in various morphologic features and immunohistochemical staining patterns. In the 16 benign cases, no significant morphologic differences were found between the TCB and Cellient cell block sections. For the 19 malignant cases, some noticeable differences in the nuclear chromatin and cellularity were identified, although statistical significance was not attained. Immunohistochemical or special stains were performed on 89% of the malignant cases (17/19). Inadequate cellularity precluded full evaluation in 23% of Cellient cell block IHC preparations (4/17). Of the malignant cases with adequate cellularity (13/17), the immunohistochemical staining patterns from the different methods were identical in 53% of cases. The traditional and Cellient cell block sections showed similar morphologic and immunohistochemical staining patterns. The only significant difference between the two methods concerned the lower overall cell block cellularity identified during immunohistochemical staining in the Cellient cell block sections. Copyright © 2010 Wiley-Liss, Inc.
Yamanel, Kivanc; Caglar, Alper; Özcan, Mutlu; Gulsah, Kamran; Bagis, Bora
2010-12-01
This study evaluated the color parameters of resin composite shade guides determined using a colorimeter and digital imaging method. Four composite shade guides, namely: two nanohybrid (Grandio [Voco GmbH, Cuxhaven, Germany]; Premise [KerrHawe SA, Bioggio, Switzerland]) and two hybrid (Charisma [Heraeus Kulzer, GmbH & Co. KG, Hanau, Germany]; Filtek Z250 [3M ESPE, Seefeld, Germany]) were evaluated. Ten shade tabs were selected (A1, A2, A3, A3,5, A4, B1, B2, B3, C2, C3) from each shade guide. CIE Lab values were obtained using digital imaging and a colorimeter (ShadeEye NCC Dental Chroma Meter, Shofu Inc., Kyoto, Japan). The data were analyzed using two-way analysis of variance and Bonferroni post hoc test. Overall, the mean ΔE values from different composite pairs demonstrated statistically significant differences when evaluated with the colorimeter (p < 0.001) but there was no significant difference with the digital imaging method (p = 0.099). With both measurement methods in total, 80% of the shade guide pairs from different composites (97/120) showed color differences greater than 3.7 (moderately perceptible mismatch), and 49% (59/120) had obvious mismatch (ΔE > 6.8). For all shade pairs evaluated, the most significant shade mismatches were obtained between Grandio-Filtek Z250 (p = 0.021) and Filtek Z250-Premise (p = 0.01) regarding ΔE mean values, whereas the best shade match was between Grandio-Charisma (p = 0.255) regardless of the measurement method. The best color match (mean ΔE values) was recorded for A1, A2, and A3 shade pairs in both methods. When proper object-camera distance, digital camera settings, and suitable illumination conditions are provided, digital imaging method could be used in the assessment of color parameters. Interchanging use of shade guides from different composite systems should be avoided during color selection. © 2010, COPYRIGHT THE AUTHORS. JOURNAL COMPILATION © 2010, WILEY PERIODICALS, INC.
Analysis of Cortical Shape in Children with Simplex Autism
Dierker, Donna L.; Feczko, Eric; Pruett, John R.; Petersen, Steven E.; Schlaggar, Bradley L.; Constantino, John N.; Harwell, John W.; Coalson, Timothy S.; Van Essen, David C.
2015-01-01
We used surface-based morphometry to test for differences in cortical shape between children with simplex autism (n = 34, mean age 11.4 years) and typical children (n = 32, mean age 11.3 years). This entailed testing for group differences in sulcal depth and in 3D coordinates after registering cortical midthickness surfaces to an atlas target using 2 independent registration methods. We identified bilateral differences in sulcal depth in restricted portions of the anterior-insula and frontal-operculum (aI/fO) and in the temporoparietal junction (TPJ). The aI/fO depth differences are associated with and likely to be caused by a shape difference in the inferior frontal gyrus in children with simplex autism. Comparisons of average midthickness surfaces of children with simplex autism and those of typical children suggest that the significant sulcal depth differences represent local peaks in a larger pattern of regional differences that are below statistical significance when using coordinate-based analysis methods. Cortical regions that are statistically significant before correction for multiple measures are peaks of more extended, albeit subtle regional differences that may guide hypothesis generation for studies using other imaging modalities. PMID:24165833
Zagatina, A; Guseva, O; Bartosh-Zelenaya, S Y; Zhuravskaya, N
2014-04-01
Ischemic segments cannot develop a sufficient amount of strength during systole, so theoretically they begin to contract later in comparison with non-ischemic zones. There is a lack of information about methods that can detect dyssynchrony during exercise in patients with QRS not longer 100 ms. The aim of the study was to compare different methods of detection regarding left ventricular moving dyssynchrony in patients with significant coronary stenosis artery lesions: pulsed-wave of PW-TDI, strain (S) and strain rate (SR). The study included 133 subjects: 106 consecutive patients who were scheduled for coronary angiography with previous stress-echocardiography and 27 healthy persons. All the patients underwent a supine bicycle exercise test. Seventy-six patients had stenoses and 30 subjects had no significant lesions by coronary angiography. There was a detectable difference between time parameters of left ventricle contraction for the two groups and controls before and during exercise using all Doppler methods. Subgroups of patients without previous myocardial infarction and without hypertrophy of left ventricle had the same results. Maximal difference was observed using strain method. There was a moderate correlation between time parameters and the existence of significant lesions of coronary arteries. Patients without prolongations of QRS with significant lesions of coronary arteries have detectable left ventricular dyssynchrony before and during exercise.
Sa-ngasoongsong, Paphon; Chanplakorn, Pongsthorn; Wongsak, Siwadol; Uthadorn, Krisorn; Panpikoon, Tanapong; Jittorntam, Paisan; Aryurachai, Katcharin; Angchaisukisiri, Pantap; Kawinwonggowit, Viroj
2015-01-01
Background. Recently, combined intra-articular tranexamic acid (IA-TXA) injection with clamping drain method showed efficacy for blood loss and transfusion reduction in total knee replacement (TKR). However, until now, none of previous studies revealed the effect of this technique on pharmacokinetics, coagulation, and fibrinolysis. Materials and Methods. An experimental study was conducted, during 2011-2012, in 30 patients undergoing unilateral TKR. Patients received IA-TXA application and then were allocated into six groups regarding clamping drain duration (2-, 4-, 6-, 8-, 10-, and 12-hours). Blood and drainage fluid were collected to measure tranexamic acid (TXA) level and related coagulation and fibrinolytic markers. Postoperative complication was followed for one year. Results. There was no significant difference of serum TXA level at 2 hour and 24 hour among groups (p < 0.05). Serum TXA level at time of clamp release was significantly different among groups with the highest level at 2 hour (p < 0.0001). There was no significant difference of TXA level in drainage fluid, postoperative blood loss, blood transfusion, and postoperative complications (p < 0.05). Conclusions. Low-dose IA-TXA application in TKR with prolonged clamping drain method is a safe and effective blood conservative technique with only minimal systemic absorption and without significant increase in systemic absorption over time. PMID:26583092
Ozkir, Serhat Emre; Yilmaz, Burak; Unal, Server Mutluay; Culhaoglu, Ahmet; Kurkcuoglu, Isin
2018-01-01
Objective: The objective of this study is the effect of different heat polymerization conditions on the strength of polymethyl methacrylate (PMMA) resin base is unknown. Distinguishing one method that provides improved mechanical properties may be beneficial to the clinical success of complete and partial dentures and overdentures. The purpose of this study was to evaluate the effect of different polymerization methods on the flexural strength of a dental PMMA resin. Materials and Methods: Forty PMMA specimens (64 mm × 10 mm × 4 mm) were prepared with 4 different polymerization methods (n = 10); heat polymerization at 74°C for 9 h, at 100°C for 40 min, and with 620 kPa pressure at 100°C for 20 min. The remaining group of specimens was microwave polymerized at 180 W for 6 min. All specimens were thermocycled at 5°C and 55°C for 5000 times. Three-point flexure test was used to measure the flexural strength of specimens. One-way ANOVA and Tukey Honestly Significant Difference were applied to analyze the differences in flexural strengths (α = 0.05). Results: The flexural strength of heat-polymerized groups was similar. The flexural strength of microwave polymerized group was significantly different and lower than the other groups (P < 0.05). Conclusion: Polymerizing conventional heat-polymerizing PMMA resin with microwave energy resulted in a significant decrease in flexural strength. The results of this study suggest that clinicians may benefit from using heat polymerization when processing PMMA denture bases instead of microvawe polymerization when tested brand is used. PMID:29657535
Khalighinejad, Pooyan; Rahimi, Mojtaba; Naghibi, Khosro; Niknam, Negar
2015-01-01
Surgeries may trigger the stress response which leads to changes in blood glucose level, and studies suggest that different sedation and anesthesia methods have different effects on blood glucose level. The aim of this study was to investigate changes of blood glucose levels in diabetic patients and compare them in two sedation methods of propofol + fentanyl and midazolam + fentanyl. Totally, 80 diabetic candidates for cataract surgery who had all the inclusion criteria, underwent cataract surgery using two methods of propofol (1 mg/kg/h) + fentanyl (2 μg/kg) (Group P) and midazolam (0.03 mg/kg) + fentanyl (2 μg/kg) (Group M) for light sedation. In the end, 70 patients (Group P n = 35 and Group M n = 35) remained in the study. Patients' blood glucose levels, vital signs, and hemodynamic data were assessed 30 min prior to the surgery, each 15 min during surgery and at the end of surgery. Hemodynamic parameters did not have a statistically significant difference between the two groups mean blood glucose level in Group M was 149.15 mg/dl and in Group P was 149.2 mg/dl, and based on repeated measures analysis of variance test, significant differences were not observed between the two groups (P = 0.99). T-test showed no significant differences in the blood glucose level at any time of the study between the two groups. Light sedation methods of propofol + fentanyl and midazolam + fentanyl did not have any differences in alteration of blood glucose level.
Comparison of prosthetic models produced by traditional and additive manufacturing methods.
Park, Jin-Young; Kim, Hae-Young; Kim, Ji-Hwan; Kim, Jae-Hong; Kim, Woong-Chul
2015-08-01
The purpose of this study was to verify the clinical-feasibility of additive manufacturing by comparing the accuracy of four different manufacturing methods for metal coping: the conventional lost wax technique (CLWT); subtractive methods with wax blank milling (WBM); and two additive methods, multi jet modeling (MJM), and micro-stereolithography (Micro-SLA). Thirty study models were created using an acrylic model with the maxillary upper right canine, first premolar, and first molar teeth. Based on the scan files from a non-contact blue light scanner (Identica; Medit Co. Ltd., Seoul, Korea), thirty cores were produced using the WBM, MJM, and Micro-SLA methods, respectively, and another thirty frameworks were produced using the CLWT method. To measure the marginal and internal gap, the silicone replica method was adopted, and the silicone images obtained were evaluated using a digital microscope (KH-7700; Hirox, Tokyo, Japan) at 140X magnification. Analyses were performed using two-way analysis of variance (ANOVA) and Tukey post hoc test (α=.05). The mean marginal gaps and internal gaps showed significant differences according to tooth type (P<.001 and P<.001, respectively) and manufacturing method (P<.037 and P<.001, respectively). Micro-SLA did not show any significant difference from CLWT regarding mean marginal gap compared to the WBM and MJM methods. The mean values of gaps resulting from the four different manufacturing methods were within a clinically allowable range, and, thus, the clinical use of additive manufacturing methods is acceptable as an alternative to the traditional lost wax-technique and subtractive manufacturing.
Provost, Karine; Leblond, Antoine; Gauthier-Lemire, Annie; Filion, Édith; Bahig, Houda; Lord, Martin
2017-09-01
Planar perfusion scintigraphy with 99m Tc-labeled macroaggregated albumin is often used for pretherapy quantification of regional lung perfusion in lung cancer patients, particularly those with poor respiratory function. However, subdividing lung parenchyma into rectangular regions of interest, as done on planar images, is a poor reflection of true lobar anatomy. New tridimensional methods using SPECT and SPECT/CT have been introduced, including semiautomatic lung segmentation software. The present study evaluated inter- and intraobserver agreement on quantification using SPECT/CT software and compared the results for regional lung contribution obtained with SPECT/CT and planar scintigraphy. Methods: Thirty lung cancer patients underwent ventilation-perfusion scintigraphy with 99m Tc-macroaggregated albumin and 99m Tc-Technegas. The regional lung contribution to perfusion and ventilation was measured on both planar scintigraphy and SPECT/CT using semiautomatic lung segmentation software by 2 observers. Interobserver and intraobserver agreement for the SPECT/CT software was assessed using the intraclass correlation coefficient, Bland-Altman plots, and absolute differences in measurements. Measurements from planar and tridimensional methods were compared using the paired-sample t test and mean absolute differences. Results: Intraclass correlation coefficients were in the excellent range (above 0.9) for both interobserver and intraobserver agreement using the SPECT/CT software. Bland-Altman analyses showed very narrow limits of agreement. Absolute differences were below 2.0% in 96% of both interobserver and intraobserver measurements. There was a statistically significant difference between planar and SPECT/CT methods ( P < 0.001) for quantification of perfusion and ventilation for all right lung lobes, with a maximal mean absolute difference of 20.7% for the right middle lobe. There was no statistically significant difference in quantification of perfusion and ventilation for the left lung lobes using either method; however, absolute differences reached 12.0%. The total right and left lung contributions were similar for the two methods, with a mean difference of 1.2% for perfusion and 2.0% for ventilation. Conclusion: Quantification of regional lung perfusion and ventilation using SPECT/CT-based lung segmentation software is highly reproducible. This tridimensional method yields statistically significant differences in measurements for right lung lobes when compared with planar scintigraphy. We recommend that SPECT/CT-based quantification be used for all lung cancer patients undergoing pretherapy evaluation of regional lung function. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chrisp, C.; Hobbs, C.; Clark, R.
1979-01-01
This experiment showed that mutagenicity of fly ash derived from different coal conversion technologies, as determined by the Ames plate incorporation test, was similar in all three laboratories. The differences in mutagenic activity of each fly ash between laboratories with different solvent extraction methods were no greater than one order of magnitude. In addition, there were much smaller, but still significant differences in mutagenic activity between laboratories when the same solvent extract of a particular fly ash was tested in each laboratory. There were also significant differences in mutagenicity of the positive control mutagen (maximum of fivefold) between laboratories. Becausemore » of this difference in Ames test sensitivity between laboratories, the influence of the solvent extraction methods on differences in mutagenicity was not clear. However, the data suggested that either there were significant differences in the degree of sensitivity of Ames tests for different complex mixtures within each laboratory, or else there were differences in mutagen extraction efficiency between different solvent extraction methods. Both Ames test sensitivity and solvent extraction may be important. Further work would be necessary to separate the contribution of these two factors. An important aspect of further work would be to separate the contribution of the innate sensitivity of substrains of Ames tester strains in each laboratory from the possible effects of differences in Ames testing methodology. This could be done by testing the same extracts of fly ash and positive control mutagens with substrains of tester strains exchanged between laboratories. This work also implies that caution should be exercised in assuming that the same solvent would have the same efficiency for extraction of mutagens from different fly ashes even within the same laboratory.« less
Moon, Jordan R; Stout, Jeffrey R; Walter, Ashley A; Smith, Abbie E; Stock, Matt S; Herda, Trent J; Sherk, Vanessa D; Young, Kaelin C; Lockwood, Christopher M; Kendall, Kristina L; Fukuda, David H; Graef, Jennifer L; Cramer, Joel T; Beck, Travis W; Esposito, Enrico N
2011-03-01
Both load cell and mechanical scale-based hydrostatic weighing (HW) systems are used for the measurement of underwater weight. However, there has been no direct comparison of the 2 methods. The purpose of the current investigation was to simultaneously compare a load cell and mechanical scale for use in HW. Twenty-seven men and women (mean ± SD, age: 22 ± 2 years) participated in the 2-day investigation. Each subject completed 2 HW assessments 24 hours apart. Single-day comparisons of all trials for both days revealed no significant difference between the mechanical scale and the load cell (mean difference < 0.016 kg, p > 0.05). True underwater weight values were not significantly different between methods for either days (mean difference < 0.014 kg, p > 0.05) and accounted for a mean difference in percent fat (%FAT) of <0.108%. The 95% limits of agreement indicated a maximum difference between methods of 0.53% FAT. Both methods produced similar reliability SEM values (mechanical SEM < 0.72%FAT, load cell SEM < 0.75%FAT). In conclusion, there was no difference between mechanical scale and load cell measurements of underwater weights and the added precision of the load cell only marginally (<0.16%FAT) improved day-to-day reliability. Either a mechanical scale or load cell can be used for HW with similar accuracy and reliability in young adults with a body mass index of 18.7-34.4 (5-25%FAT).
Slotved, H C; Roepstorff, A; Barnes, E H; Eriksen, L; Nansen, P
1996-08-01
Nine groups of 5 pigs were inoculated with Ascaris suum eggs on day 0. Groups 1, 2, and 3 were inoculated with 100 eggs, groups 4, 5, and 6 with 1,000 eggs, and groups 7, 8, and 9 with 10,000 eggs. On day 3, groups 1, 4, and 7 were slaughtered, on day 7 groups 2, 5, and 8, and on day 10 groups 3, 6, and 9. The liver (days 3 and 7) and lungs (days 3, 7, and 10) were removed and 2, 25% samples of both organs were collected. Larvae were recovered from 1 sample by the Baermann method and from the other by an agar-gel method. Overall there were no significant differences in the liver larval recovery between the 2 methods. The use of the agar-gel method resulted in a very clean suspension of larvae and thereby reduced the sample counting time by a factor of 5-10 compared to the Baermann method. With both methods larval recovery from the lungs resulted in a clean larval suspension that was easy to count, and there were overall no significant differences between the 2 methods, although there was a tendency toward the Baermann method recovering more larvae from the lungs than the agar-gel method. The tissue sample dry weight did not significantly influence larval recovery by the agar-gel method, and the time interval from slaughtering to start of incubation on day 3 (interval 51-92 min), day 7 (interval 37-114 min), and day 10 (interval 50-129 min) had no significant effect on recovery by either method.
Mika, Anna; Oleksy, Łukasz; Kielnar, Renata; Wodka-Natkaniec, Ewa; Twardowska, Magdalena; Kamiński, Kamil; Małek, Zbigniew
2016-01-01
Background The aim of this study is to assess if the application of different methods of active recovery (working the same or different muscle groups from those which were active during fatiguing exercise) results in significant differences in muscle performance and if the efficiency of the active recovery method is dependent upon the specific sport activity (training loads). Design A parallel group non-blinded trial with repeated measurements. Methods Thirteen mountain canoeists and twelve football players participated in this study. Measurements of the bioelectrical activity, torque, work and power of the vastus lateralis oblique, vastus medialis oblique, and rectus femoris muscles were performed during isokinetic tests at a velocity of 90°/s. Results Active legs recovery in both groups was effective in reducing fatigue from evaluated muscles, where a significant decrease in fatigue index was observed. The muscles peak torque, work and power parameters did not change significantly after both modes of active recovery, but in both groups significant decrease was seen after passive recovery. Conclusions We suggest that 20 minutes of post-exercise active recovery involving the same muscles that were active during the fatiguing exercise is more effective in fatigue recovery than active exercise using the muscles that were not involved in the exercise. Active arm exercises were less effective in both groups which indicates a lack of a relationship between the different training regimens and the part of the body which is principally used during training. PMID:27706260
Evaluation of pulse-oximetry oxygen saturation taken through skin protective covering.
James, Jyotsna; Tiwari, Lokesh; Upadhyay, Pramod; Sreenivas, Vishnubhatla; Bhambhani, Vikas; Puliyel, Jacob M
2006-05-06
The hard edges of adult finger clip probes of the pulse oximetry oxygen saturation (POOS) monitor can cause skin damage if used for prolonged periods in a neonate. Covering the skin under the probe with Micropore surgical tape or a gauze piece might prevent such injury. The study was done to see if the protective covering would affect the accuracy of the readings. POOS was studied in 50 full-term neonates in the first week of life. After obtaining consent from their parents the neonates had POOS readings taken directly (standard technique) and through the protective covering. Bland-Altman plots were used to compare the new method with the standard technique. A test of repeatability for each method was also performed. The Bland-Altman plots suggest that there is no significant loss of accuracy when readings are taken through the protective covering. The mean difference was 0.06 (SD of 1.39) and 0.04 (SD 1.3) with Micropore and gauze respectively compared to the standard method. The mean difference was 0.22 (SD 0.23) on testing repeatability with the standard method. Interposing Micropore or gauze does not significantly affect the accuracy of the POOS reading. The difference between the standard method and the new method was less than the difference seen on testing repeatability of the standard method.
Bellvert, Joaquim; Crombie, Kieran; Horgan, Finbarr G.
2008-01-01
The Fenwick can and Schuiling centrifuge are widely used to extract nematode cysts from soil samples. The comparative efficiencies of these two methods during cyst extraction have not been determined for different soil types under different cyst densities. Such information is vital for statutory laboratories that must choose a method for routine, high-throughput soil monitoring. In this study, samples of different soil types seeded with varying densities of potato cyst nematode (Globodera rostochiensis) cysts were processed using both methods. In one experiment, with 200 ml samples, recovery was similar between methods. In a second experiment with 500 ml samples, cyst recovery was higher using the Schuiling centrifuge. For each method and soil type, cyst extraction efficiency was similar across all densities tested. Extraction was efficient from pure sand (Fenwick 72%, Schuiling 84%) and naturally sandy soils (Fenwick 62%, Schuiling 73%), but was significantly less efficient from clay-soil (Fenwick 42%, Schuiling 44%) and peat-soil with high organic matter content (Fenwick 35%, Schuiling 33%). Residual moisture (<10% w/w) in samples prior to analyses reduced extraction efficiency, particularly for sand and sandy soils. For each soil type and method, there were significant linear relationships between the number of cysts extracted and the numbers of cysts in the samples. We discuss the advantages and disadvantages of each extraction method for cyst extraction in statutory soil laboratories. PMID:19259516
Marimuthu, K; Thilaga, M; Kathiresan, S; Xavier, R; Mas, R H M H
2012-06-01
The effects of different cooking methods (boiling, baking, frying and grilling) on proximate and mineral composition of snakehead fish were investigated. The mean content of moisture, protein, fat and ash of raw fish was found to be 77.2 ± 2.39, 13.9 ± 2.89, 5.9 ± 0.45 and 0.77 ± 0.12% respectively. The changes in the amount of protein and fat were found to be significantly higher in frying and grilling fish. The ash content increased significantly whereas that of the minerals (Na, K, Ca, Mg, Fe, Zn and Mn) was not affected in all cooking methods. Increased in Cu contents and decreased in P contents were observed in all cooking methods except grilling. In the present study, the grilling method of cooking is found to be the best for healthy eating.
Analysis of Sampling Methodologies for Noise Pollution Assessment and the Impact on the Population.
Rey Gozalo, Guillermo; Barrigón Morillas, Juan Miguel
2016-05-11
Today, noise pollution is an increasing environmental stressor. Noise maps are recognised as the main tool for assessing and managing environmental noise, but their accuracy largely depends on the sampling method used. The sampling methods most commonly used by different researchers (grid, legislative road types and categorisation methods) were analysed and compared using the city of Talca (Chile) as a test case. The results show that the stratification of sound values in road categories has a significantly lower prediction error and a higher capacity for discrimination and prediction than in the legislative road types used by the Ministry of Transport and Telecommunications in Chile. Also, the use of one or another method implies significant differences in the assessment of population exposure to noise pollution. Thus, the selection of a suitable method for performing noise maps through measurements is essential to achieve an accurate assessment of the impact of noise pollution on the population.
Accuracy of estimating wolf summer territories by daytime locations
Demma, D.J.; Mech, L.D.
2011-01-01
We used locations of 6 wolves (Canis lupus) in Minnesota from Global Positioning System (GPS) collars to compare day-versus-night locations to estimate territory size and location during summer. We employed both minimum convex polygon (MCP) and fixed kernel (FK) methods. We used two methods to partition GPS locations for day-versus-night home-range comparisons: (1) daytime = 0800-2000 Ah; nighttime = 2000-0800 Ah; and (2) sunup versus sundown. Regardless of location-partitioning method, mean area of daytime MCPs did not differ significantly from nighttime MCPs. Similarly, mean area of daytime FKs (95% probability contour) were not significantly different from nightime FKs. FK core use areas (50% probability contour) did not differ between daytime and nighttime nor between sunup and sundown locations. We conclude that in areas similar to our study area day-only locations are adequate for describing the location, extent and core use areas of summer wolf territories by both MCP and FK methods. ?? 2011 American Midland Naturalist.
Accuracy of estimating wolf summer territories by daytime locations
Demma, Dominic J.; Mech, L. David
2011-01-01
We used locations of 6 wolves (Canis lupus) in Minnesota from Global Positioning System (GPS) collars to compare day-versus-night locations to estimate territory size and location during summer. We employed both minimum convex polygon (MCP) and fixed kernel (FK) methods. We used two methods to partition GPS locations for day-versus-night home-range comparisons: (1) daytime = 0800–2000 h; nighttime = 2000–0800 h; and (2) sunup versus sundown. Regardless of location-partitioning method, mean area of daytime MCPs did not differ significantly from nighttime MCPs. Similarly, mean area of daytime FKs (95% probability contour) were not significantly different from nightime FKs. FK core use areas (50% probability contour) did not differ between daytime and nighttime nor between sunup and sundown locations. We conclude that in areas similar to our study area day-only locations are adequate for describing the location, extent and core use areas of summer wolf territories by both MCP and FK methods.
Shao, Li-na; Wang, Xue-mei; Qiu, Li-hong; Zhan, Fu-liang; Xue, Ming
2013-08-01
To apply problem-based learning (PBL) in pre-job training of postgraduate students in department of endodontics. Thirty master degree postgraduate students of China Medical University were randomly divided into 2 groups, there were 15 students in each group. One group were taught with PBL method while the other group with lecture-based learning (LBL) method. The teaching effect was measured with examination and questionnaire survey. The data were analyzed by student's t-test using SPSS 11.5 software package. There was no significant difference in basic knowledge, medical records writing, oral examination between the two groups (P>0.05). There were significant differences in case analysis, dental operation, theory examination, practical examination and total scores between the two groups (P<0.05). The PBL method was welcomed by master degree postgraduate students. The abilities of postgraduate students can be developed by PBL method in different aspects. PBL achieves satisfactory teaching effect, and can be applied in pre-job training of postgraduate students.
Statistical analysis of traversal behavior under different types of traffic lights
NASA Astrophysics Data System (ADS)
Wang, Boran; Wang, Ziyang; Li, Zhiyin
2017-12-01
According to the video observation, it is found that the traffic signal type signal has a significant effect on the illegal crossing behavior of pedestrians at the intersection. Through the method of statistical analysis and variance analysis, the difference between the violation rate and the waiting position of pedestrians at different intersecting lights is compared, and the influence of traffic signal type on pedestrian crossing behavior is evaluated. The results show that the violation rate of the intersection of the static pedestrian lights is significantly higher than that of the countdown signal lights. There are significant differences in the waiting position of the intersection of different signal lights.
Platelet-rich plasma differs according to preparation method and human variability.
Mazzocca, Augustus D; McCarthy, Mary Beth R; Chowaniec, David M; Cote, Mark P; Romeo, Anthony A; Bradley, James P; Arciero, Robert A; Beitzel, Knut
2012-02-15
Varying concentrations of blood components in platelet-rich plasma preparations may contribute to the variable results seen in recently published clinical studies. The purposes of this investigation were (1) to quantify the level of platelets, growth factors, red blood cells, and white blood cells in so-called one-step (clinically used commercial devices) and two-step separation systems and (2) to determine the influence of three separate blood draws on the resulting components of platelet-rich plasma. Three different platelet-rich plasma (PRP) separation methods (on blood samples from eight subjects with a mean age [and standard deviation] of 31.6 ± 10.9 years) were used: two single-spin processes (PRPLP and PRPHP) and a double-spin process (PRPDS) were evaluated for concentrations of platelets, red and white blood cells, and growth factors. Additionally, the effect of three repetitive blood draws on platelet-rich plasma components was evaluated. The content and concentrations of platelets, white blood cells, and growth factors for each method of separation differed significantly. All separation techniques resulted in a significant increase in platelet concentration compared with native blood. Platelet and white blood-cell concentrations of the PRPHP procedure were significantly higher than platelet and white blood-cell concentrations produced by the so-called single-step PRPLP and the so-called two-step PRPDS procedures, although significant differences between PRPLP and PRPDS were not observed. Comparing the results of the three blood draws with regard to the reliability of platelet number and cell counts, wide variations of intra-individual numbers were observed. Single-step procedures are capable of producing sufficient amounts of platelets for clinical usage. Within the evaluated procedures, platelet numbers and numbers of white blood cells differ significantly. The intra-individual results of platelet-rich plasma separations showed wide variations in platelet and cell numbers as well as levels of growth factors regardless of separation method.
Yang, Ziyi; Wang, Wen; Zhang, Shuyu; Ma, Zonghu; Anwar, Naveed; Liu, Guangqing; Zhang, Ruihong
2017-04-01
The methane production potential of kitchen waste (KW) obtained from different sources was compared through mesophilic and thermophilic anaerobic digestion. The methane yields (MYs) obtained with the same KW sample under different temperatures were similar, whereas the MYs obtained with different samples differed significantly. The highest MY obtained in S7 was 54%-60% higher than the lowest MY in S3. The modified Gompertz model was utilized to simulate the methane production process. The maximum production rate of methane under thermophilic conditions was 2%-86% higher than that under mesophilic conditions. The characteristics of different KW samples were studied. In the distribution of total chemical oxygen demand, the diversity of organic compounds of KW was the most dominant factor that affected the potential MYs of KW. The effect of the C/N and C/P ratios or the concentration of metal ions was insignificant. Two typical methods to calculate the theoretical MY (TMY) were compared, the organic composition method can simulate methane production more precisely than the elemental analysis method. Significant linear correlations were found between TMY org and MYs under mesophilic and thermophilic conditions. The organic composition method can thus be utilized as a fast technique to predict the methane production potential of KW.
Makkaew, P; Miller, M; Cromar, N J; Fallowfield, H J
2017-04-01
This study investigated the volume of wastewater retained on the surface of three different varieties of lettuce, Iceberg, Cos, and Oak leaf, following submersion in wastewater of different microbial qualities (10, 10 2 , 10 3 , and 10 4 E. coli MPN/100 mL) as a surrogate method for estimation of contamination of spray-irrigated lettuce. Uniquely, Escherichia coli was enumerated, after submersion, on both the outer and inner leaves and in a composite sample of lettuce. E. coli were enumerated using two techniques. Firstly, from samples of leaves - the direct method. Secondly, using an indirect method, where the E. coli concentrations were estimated from the volume of wastewater retained by the lettuce and the E. coli concentration of the wastewater. The results showed that different varieties of lettuce retained significantly different volumes of wastewater (p < 0.01). No statistical differences (p > 0.01) were detected between E. coli counts obtained from different parts of lettuce, nor between the direct and indirect enumeration methods. Statistically significant linear relationships were derived relating the E. coli concentration of the wastewater in which the lettuces were submerged to the subsequent E. coli count on each variety the lettuce.
Morphological study of the palatal rugae in western Indian population.
Gondivkar, Shailesh M; Patel, Swetal; Gadbail, Amol R; Gaikwad, Rahul N; Chole, Revant; Parikh, Rima V
2011-10-01
The aim of this study was to identify and compare the different morphological rugae patterns in males and females of western Indian population, which may be an additional method of identification in cases of crimes or aircraft accidents. A total of 108 plaster casts, equally distributed between the sexes and belonging to similar age-group, were examined for different biometric characteristics of the palatal rugae including number, shape, length, direction and unification and their incidence recorded. Association between these rugae biometric characteristics and sex were tested using chi-square analysis and statistical descriptors were identified for each of these parameters using the SPSS 15.0. The study revealed a statistically significant difference in the total number of rugae between the two sexes (P = 0.000). The different types of rugae between the males and females were statistically compared. The female showed a highly significant difference in the sinuous (P = 0.002) and primary type (P = 0.000) while the male had a significant difference in the unification (P = 0.005). The predominant direction of the rugae was found to be forward relative to backward. It may be concluded that the rugae pattern can be an additional method of differentiation between the male and female in conjunction with the other methods such as visual, fingerprints, and dental characteristics in forensic sciences. Copyright © 2011 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.
Saad, Ahmed S; Attia, Ali K; Alaraki, Manal S; Elzanfaly, Eman S
2015-11-05
Five different spectrophotometric methods were applied for simultaneous determination of fenbendazole and rafoxanide in their binary mixture; namely first derivative, derivative ratio, ratio difference, dual wavelength and H-point standard addition spectrophotometric methods. Different factors affecting each of the applied spectrophotometric methods were studied and the selectivity of the applied methods was compared. The applied methods were validated as per the ICH guidelines and good accuracy; specificity and precision were proven within the concentration range of 5-50 μg/mL for both drugs. Statistical analysis using one-way ANOVA proved no significant differences among the proposed methods for the determination of the two drugs. The proposed methods successfully determined both drugs in laboratory prepared and commercially available binary mixtures, and were found applicable for the routine analysis in quality control laboratories. Copyright © 2015 Elsevier B.V. All rights reserved.
1982-10-01
K-S A R A j 1 10 23 R 3 8 11 16 18 For the lognormal methods the test methods sometimes give different results. The K-S test and the chi-square...significant difference among the three test methods . A previous study has been done using 24 data sets of electronic systems and equipments, using only the W...are suitable descriptors for corrective maintenance repair times, and to estimate the difference caused in assuming an exponential distribution for
Shen, L; Robberecht, H; Van Dael, P; Deelstra, H
1995-01-01
The availability of zinc and calcium from human, cow's, goat, and sheep milk is evaluated by an in vitro method that involves a simulated human gastrointestinal digestion followed by measurement of dialyzability of zinc and calcium. Zinc availability of milk showed the highest value for human milk (15.0%) and the lowest for sheep milk (1.0%), in both whole and skim milk. Calcium availability of the different types of milk did not differ significantly and ranged between 18 and 23%. No significant differences in availability between whole and skim milk were found for both elements, except for zinc in cow's milk.
NASA Technical Reports Server (NTRS)
Xu, Kuan-Man
2006-01-01
A new method is proposed to compare statistical differences between summary histograms, which are the histograms summed over a large ensemble of individual histograms. It consists of choosing a distance statistic for measuring the difference between summary histograms and using a bootstrap procedure to calculate the statistical significance level. Bootstrapping is an approach to statistical inference that makes few assumptions about the underlying probability distribution that describes the data. Three distance statistics are compared in this study. They are the Euclidean distance, the Jeffries-Matusita distance and the Kuiper distance. The data used in testing the bootstrap method are satellite measurements of cloud systems called cloud objects. Each cloud object is defined as a contiguous region/patch composed of individual footprints or fields of view. A histogram of measured values over footprints is generated for each parameter of each cloud object and then summary histograms are accumulated over all individual histograms in a given cloud-object size category. The results of statistical hypothesis tests using all three distances as test statistics are generally similar, indicating the validity of the proposed method. The Euclidean distance is determined to be most suitable after comparing the statistical tests of several parameters with distinct probability distributions among three cloud-object size categories. Impacts on the statistical significance levels resulting from differences in the total lengths of satellite footprint data between two size categories are also discussed.
Wang, Wentao; Meng, Bingjun; Lu, Xiaoxia; Liu, Yu; Tao, Shu
2007-10-29
The methods of simultaneous extraction of polycyclic aromatic hydrocarbons (PAHs) and organochlorine pesticides (OCPs) from soils using Soxhlet extraction, microwave-assisted extraction (MAE) and accelerated solvent extraction (ASE) were established, and the extraction efficiencies using the three methods were systemically compared from procedural blank, limits of detection and quantification, method recovery and reproducibility, method chromatogram and other factors. In addition, soils with different total organic carbon contents were used to test the extraction efficiencies of the three methods. The results showed that the values obtained in this study were comparable with the values reported by other studies. In some respects such as method recovery and reproducibility, there were no significant differences among the three methods for the extraction of PAHs and OCPs. In some respects such as procedural blank and limits of detection and quantification, there were significant differences among the three methods. Overall, ASE had the best extraction efficiency compared to MAE and Soxhlet extraction, and the extraction efficiencies of MAE and Soxhlet extraction were comparable to each other depending on the property such as TOC content of the studied soil. Considering other factors such as solvent consumption and extraction time, ASE and MAE are preferable to Soxhlet extraction.
Atwood, Meredith A
2013-04-30
Stable isotope analysis is a critical tool for understanding ecological food webs; however, results can be sensitive to sample preparation methods. To limit the possibility of sample contamination, freezing is commonly used to euthanize invertebrates and preserve non-lethal samples from vertebrates. For destructive sampling of vertebrates, more humane euthanasia methods are preferred to freezing and it is essential to evaluate how these euthanasia methods affect stable isotope results. Stable isotope ratios and elemental composition of carbon and nitrogen were used to evaluate whether the euthanasia method compromised the integrity of the sample for analysis. Specifically, the stable isotope and C:N ratios were compared for larval wood frogs (Rana sylvatica = Lithobates sylvaticus), an ectothermic vertebrate, that had been euthanized by freezing with four different humane euthanasia methods: CO2, benzocaine, MS-222 (tricaine methanesulfonate), and 70% ethanol. The euthanasia method was not related to the δ(13)C or δ(15)N values and the comparisons revealed no differences between freezing and any of the other treatments. However, there were slight (non-significant) differences in the isotope ratios of benzocaine and CO2 when each was compared with freezing. The elemental composition was altered by the euthanasia method employed. The percentage nitrogen was higher in CO2 treatments than in freezing, and similar (non-significant) trends were seen for ethanol treatments relative to freezing. The resulting C:N ratios were higher for benzocaine treatments than for both CO2 and ethanol. Similar (non-significant) trends suggested that the C:N ratios were also higher for animals euthanized by freezing than for both CO2 and ethanol euthanasia methods. The euthanasia method had a larger effect on elemental composition than stable isotope ratios. The percentage nitrogen and the subsequent C:N ratios were most affected by the CO2 and ethanol euthanasia methods, whereas non-significant trends suggested that benzocaine and CO2 altered the stable isotope ratios. It appears that the use of MS-222 and freezing with dry ice are the most appropriate euthanasia methods for ectothermic vertebrates. Copyright © 2013 John Wiley & Sons, Ltd.
Ohno, Yoshiharu; Nishio, Mizuho; Koyama, Hisanobu; Fujisawa, Yasuko; Yoshikawa, Takeshi; Matsumoto, Sumiaki; Sugimura, Kazuro
2013-06-01
The objective of our study was to prospectively compare the capability of dynamic area-detector CT analyzed with different mathematic methods and PET/CT in the management of pulmonary nodules. Fifty-two consecutive patients with 96 pulmonary nodules underwent dynamic area-detector CT, PET/CT, and microbacterial or pathologic examinations. All nodules were classified into the following groups: malignant nodules (n = 57), benign nodules with low biologic activity (n = 15), and benign nodules with high biologic activity (n = 24). On dynamic area-detector CT, the total, pulmonary arterial, and systemic arterial perfusions were calculated using the dual-input maximum slope method; perfusion was calculated using the single-input maximum slope method; and extraction fraction and blood volume (BV) were calculated using the Patlak plot method. All indexes were statistically compared among the three nodule groups. Then, receiver operating characteristic analyses were used to compare the diagnostic capabilities of the maximum standardized uptake value (SUVmax) and each perfusion parameter having a significant difference between malignant and benign nodules. Finally, the diagnostic performances of the indexes were compared by means of the McNemar test. No adverse effects were observed in this study. All indexes except extraction fraction and BV, both of which were calculated using the Patlak plot method, showed significant differences among the three groups (p < 0.05). Areas under the curve of total perfusion calculated using the dual-input method, pulmonary arterial perfusion calculated using the dual-input method, and perfusion calculated using the single-input method were significantly larger than that of SUVmax (p < 0.05). The accuracy of total perfusion (83.3%) was significantly greater than the accuracy of the other indexes: pulmonary arterial perfusion (72.9%, p < 0.05), systemic arterial perfusion calculated using the dual-input method (69.8%, p < 0.05), perfusion (66.7%, p < 0.05), and SUVmax (60.4%, p < 0.05). Dynamic area-detector CT analyzed using the dual-input maximum slope method has better potential for the diagnosis of pulmonary nodules than dynamic area-detector CT analyzed using other methods and than PET/CT.
Comparisons of topological properties in autism for the brain network construction methods
NASA Astrophysics Data System (ADS)
Lee, Min-Hee; Kim, Dong Youn; Lee, Sang Hyeon; Kim, Jin Uk; Chung, Moo K.
2015-03-01
Structural brain networks can be constructed from the white matter fiber tractography of diffusion tensor imaging (DTI), and the structural characteristics of the brain can be analyzed from its networks. When brain networks are constructed by the parcellation method, their network structures change according to the parcellation scale selection and arbitrary thresholding. To overcome these issues, we modified the Ɛ -neighbor construction method proposed by Chung et al. (2011). The purpose of this study was to construct brain networks for 14 control subjects and 16 subjects with autism using both the parcellation and the Ɛ-neighbor construction method and to compare their topological properties between two methods. As the number of nodes increased, connectedness decreased in the parcellation method. However in the Ɛ-neighbor construction method, connectedness remained at a high level even with the rising number of nodes. In addition, statistical analysis for the parcellation method showed significant difference only in the path length. However, statistical analysis for the Ɛ-neighbor construction method showed significant difference with the path length, the degree and the density.
[A clinical study on different decompression methods in cervical spondylosis].
Ma, Xun; Zhao, Xiao-fei; Zhao, Yi-bo
2009-04-15
To analyze the different decompression methods to treat cervical spondylosis based on imageological evaluation. Two hundred and sixty three consecutive patients with cervical spondylosis between Nov. 2004 and Oct. 2007 were involved in this study. Patients were distributed to different operation groups based on the preoperative imageological evaluation, including anterior or posterior decompression methods. The Anterior method is to use the discectomy of one to three segments, autogenous iliac graft or titanium mesh or cage fusion and titanium plate fixation, or subtotal vertebrectomy of one to two segments autogenous iliac graft or titanium mesh fusion and titanium plate fixation, or discectomy plus subtotal vertebrectomy, The posterior expansive single open door laminoplasty and other operation types. All the patients were divided into different groups by the preoperative imageological evaluation, age, sex and course of diseases. Then we collected each group's preoperative and postoperative JOA scores and mean improvement rate to evaluate the postoperative effect by different decompression methods. Two hundred and thirty five patients were followed up with a mean period of 18 months (range, 4 to 36 months). JOA scores of all patients were improved by different degrees after operations. Anterior and posterior decompression methods both can achieve higher mean improvement rates. There were no significant differences in mean improvement rates between anterior groups, and so did male and female (P > 0.05). The effect will decrease as age increases or the course of disease prolongs. Statistical significance existed among the different age groups and between course groups (P < 0.05). Anterior and posterior decompression methods both can achieve good effect. The key point is to choose the surgical indication correctly, decompress thoroughly, and make the fusion reliable and fixation firm. In regard to the patients' imageological evaluation, the methods should be differentiated. The anterior operation type included discectomy of one to three segments, subtotal vertebrectomy of one to two segments and discectomy plus subtotal vertebra ectomy.
Comparison of six methods for isolating mycobacteria from swine lymph nodes.
Thoen, C O; Richards, W D; Jarnagin, J L
1974-03-01
Six laboratory methods were compared for isolating acid-fast bacteria. Tuberculous lymph nodes from each of 48 swine as identified by federal meat inspectors were processed by each of the methods. Treated tissue suspensions were inoculated onto each of eight media which were observed at 7-day intervals for 9 weeks. There were no statistically significant differences between the number of Mycobacterium avium complex bacteria isolated by each of the six methods. Rapid tissue preparation methods involving treatment with 2% sodium hydroxide or treatment with 0.2% zephiran required only one-third to one-fourth the processing time as a standard method. There were small differences in the amount of contamination among the six methods, but no detectable differences in the time of first appearance of M. avium complex colonies.
Covert, S. Alex
2001-01-01
The U.S. Geological Survey (USGS) and Ohio Environmental Protection Agency (OEPA) collected data on fish from 10 stream sites in 1996 and 3 stream sites in 1997 as part of a comparative study of fish community assessment methods. The sites sampled represent a wide range of basin sizes (ranging from 132?6,330 square kilometers) and surrounding land-use types (urban, agricultural, and mixed). Each agency used its own fish-sampling protocol. Using the Index of Biotic Integrity and Modified Index of Well-Being, differences between data sets were tested for significance by means of the Wilcoxon signed-ranks test (a = 0.05). Results showed that the median of Index of Biotic Integrity differences between data sets was not significantly different from zero (p = 0.2521); however, the same statistical test showed the median differences in the Modified Index of Well-Being scores to be significantly different from zero (p = 0.0158). The differences observed in the Index of Biotic Integrity scores are likely due to natural variability, increased variability at sites with degraded water quality, differences in sampling methods, and low-end adjustments in the Index of Biotic Integrity calculation when fewer than 50 fish were collected. The Modified Index of Well-Being scores calculated by OEPA were significantly higher than those calculated by the USGS. This finding was attributed to the comparatively large numbers and biomass of fish collected by the OEPA. By combining the two indices and viewing them in terms of the percentage attainment of Ohio Warmwater Habitat criteria, the two agencies? data seemed comparable, although the Index of Biotic Integrity scores were more similar than the Modified Index of Well-Being scores.
Gravimetric method for in vitro calibration of skin hydration measurements.
Martinsen, Ørjan G; Grimnes, Sverre; Nilsen, Jon K; Tronstad, Christian; Jang, Wooyoung; Kim, Hongsig; Shin, Kunsoo; Naderi, Majid; Thielmann, Frank
2008-02-01
A novel method for in vitro calibration of skin hydration measurements is presented. The method combines gravimetric and electrical measurements and reveals an exponential dependency of measured electrical susceptance to absolute water content in the epidermal stratum corneum. The results also show that absorption of water into the stratum corneum exhibits three different phases with significant differences in absorption time constant. These phases probably correspond to bound, loosely bound, and bulk water.
Heinrichs, Katherina; Székely, András; Tóth, Mónika Ditta; Coyne, James; Quintão, Sónia; Arensman, Ella; Coffey, Claire; Maxwell, Margaret; Värnik, Airi; van Audenhove, Chantal; McDaid, David; Sarchiapone, Marco; Schmidtke, Armin; Genz, Axel; Gusmão, Ricardo; Hegerl, Ulrich
2015-01-01
Background In Europe, men have lower rates of attempted suicide compared to women and at the same time a higher rate of completed suicides, indicating major gender differences in lethality of suicidal behaviour. The aim of this study was to analyse the extent to which these gender differences in lethality can be explained by factors such as choice of more lethal methods or lethality differences within the same suicide method or age. In addition, we explored gender differences in the intentionality of suicide attempts. Methods and Findings Methods. Design: Epidemiological study using a combination of self-report and official data. Setting: Mental health care services in four European countries: Germany, Hungary, Ireland, and Portugal. Data basis: Completed suicides derived from official statistics for each country (767 acts, 74.4% male) and assessed suicide attempts excluding habitual intentional self-harm (8,175 acts, 43.2% male). Main Outcome Measures and Data Analysis. We collected data on suicidal acts in eight regions of four European countries participating in the EU-funded “OSPI-Europe”-project (www.ospi-europe.com). We calculated method-specific lethality using the number of completed suicides per method * 100 / (number of completed suicides per method + number of attempted suicides per method). We tested gender differences in the distribution of suicidal acts for significance by using the χ2-test for two-by-two tables. We assessed the effect sizes with phi coefficients (φ). We identified predictors of lethality with a binary logistic regression analysis. Poisson regression analysis examined the contribution of choice of methods and method-specific lethality to gender differences in the lethality of suicidal acts. Findings Main Results Suicidal acts (fatal and non-fatal) were 3.4 times more lethal in men than in women (lethality 13.91% (regarding 4106 suicidal acts) versus 4.05% (regarding 4836 suicidal acts)), the difference being significant for the methods hanging, jumping, moving objects, sharp objects and poisoning by substances other than drugs. Median age at time of suicidal behaviour (35–44 years) did not differ between males and females. The overall gender difference in lethality of suicidal behaviour was explained by males choosing more lethal suicide methods (odds ratio (OR) = 2.03; 95% CI = 1.65 to 2.50; p < 0.000001) and additionally, but to a lesser degree, by a higher lethality of suicidal acts for males even within the same method (OR = 1.64; 95% CI = 1.32 to 2.02; p = 0.000005). Results of a regression analysis revealed neither age nor country differences were significant predictors for gender differences in the lethality of suicidal acts. The proportion of serious suicide attempts among all non-fatal suicidal acts with known intentionality (NFSAi) was significantly higher in men (57.1%; 1,207 of 2,115 NFSAi) than in women (48.6%; 1,508 of 3,100 NFSAi) (χ2 = 35.74; p < 0.000001). Main limitations of the study Due to restrictive data security regulations to ensure anonymity in Ireland, specific ages could not be provided because of the relatively low absolute numbers of suicide in the Irish intervention and control region. Therefore, analyses of the interaction between gender and age could only be conducted for three of the four countries. Attempted suicides were assessed for patients presenting to emergency departments or treated in hospitals. An unknown rate of attempted suicides remained undetected. This may have caused an overestimation of the lethality of certain methods. Moreover, the detection of attempted suicides and the registration of completed suicides might have differed across the four countries. Some suicides might be hidden and misclassified as undetermined deaths. Conclusions Men more often used highly lethal methods in suicidal behaviour, but there was also a higher method-specific lethality which together explained the large gender differences in the lethality of suicidal acts. Gender differences in the lethality of suicidal acts were fairly consistent across all four European countries examined. Males and females did not differ in age at time of suicidal behaviour. Suicide attempts by males were rated as being more serious independent of the method used, with the exceptions of attempted hanging, suggesting gender differences in intentionality associated with suicidal behaviour. These findings contribute to understanding of the spectrum of reasons for gender differences in the lethality of suicidal behaviour and should inform the development of gender specific strategies for suicide prevention. PMID:26147965
Pletzer, Belinda; M Ortner, Tuulia
2016-09-01
Personality assessment has been challenged by the fact that different assessment methods (implicit measures, behavioral measures and explicit rating scales) show little or no convergence in behavioral studies. In this neuroimaging study we address for the first time, whether different assessment methods rely on separate or overlapping neuronal systems. Fifty nine healthy adult participants completed two objective personality tests of risk propensity: the more implicit Balloon Analogue Risk Task (BART) and the more explicit Game of Dice Task (GDT). Significant differences in activation, as well as connectivity patterns between both tasks were observed. In both tasks, risky decisions yielded significantly stronger activations than safe decisions in the bilateral caudate, as well as the bilateral Insula. The finding of overlapping brain areas validates different assessment methods, despite their behavioral non-convergence. This suggests that neuroimaging can be an important tool of validation in the field of personality assessment. Copyright © 2016 Elsevier B.V. All rights reserved.
Robust gene selection methods using weighting schemes for microarray data analysis.
Kang, Suyeon; Song, Jongwoo
2017-09-02
A common task in microarray data analysis is to identify informative genes that are differentially expressed between two different states. Owing to the high-dimensional nature of microarray data, identification of significant genes has been essential in analyzing the data. However, the performances of many gene selection techniques are highly dependent on the experimental conditions, such as the presence of measurement error or a limited number of sample replicates. We have proposed new filter-based gene selection techniques, by applying a simple modification to significance analysis of microarrays (SAM). To prove the effectiveness of the proposed method, we considered a series of synthetic datasets with different noise levels and sample sizes along with two real datasets. The following findings were made. First, our proposed methods outperform conventional methods for all simulation set-ups. In particular, our methods are much better when the given data are noisy and sample size is small. They showed relatively robust performance regardless of noise level and sample size, whereas the performance of SAM became significantly worse as the noise level became high or sample size decreased. When sufficient sample replicates were available, SAM and our methods showed similar performance. Finally, our proposed methods are competitive with traditional methods in classification tasks for microarrays. The results of simulation study and real data analysis have demonstrated that our proposed methods are effective for detecting significant genes and classification tasks, especially when the given data are noisy or have few sample replicates. By employing weighting schemes, we can obtain robust and reliable results for microarray data analysis.
Zeng, Rui; Xiang, Lian-rui; Zeng, Jing; Zuo, Chuan
2017-01-01
Background We aimed to introduce team-based learning (TBL) as one of the teaching methods for diagnostics and to compare its teaching effectiveness with that of the traditional teaching methods. Methods We conducted a randomized controlled trial on diagnostics teaching involving 111 third-year medical undergraduates, using TBL as the experimental intervention, compared with lecture-based learning as the control, for teaching the two topics of symptomatology. Individual Readiness Assurance Test (IRAT)-baseline and Group Readiness Assurance Test (GRAT) were performed in members of each TBL subgroup. The scores in Individual Terminal Test 1 (ITT1) immediately after class and Individual Terminal Test 2 (ITT2) 1 week later were compared between the two groups. The questionnaire and interview were also implemented to survey the attitude of students and teachers toward TBL. Results There was no significant difference between the two groups in ITT1 (19.85±4.20 vs 19.70±4.61), while the score of the TBL group was significantly higher than that of the control group in ITT2 (19.15±3.93 vs 17.46±4.65). In the TBL group, the scores of the two terminal tests after the teaching intervention were significantly higher than the baseline test score of individuals. IRAT-baseline, ITT1, and ITT2 scores of students at different academic levels in the TBL teaching exhibited significant differences, but the ITT1-IRAT-baseline and ITT2-IRAT-baseline indicated no significant differences among the three subgroups. Conclusion Our TBL in symptomatology approach was highly accepted by students in the improvement of interest and self-directed learning and resulted in an increase in knowledge acquirements, which significantly improved short-term test scores compared with lecture-based learning. TBL is regarded as an effective teaching method worthy of promoting. PMID:28331383
Continuous measurement of tympanic temperature with a new infrared method using an optical fiber.
Shibasaki, M; Kondo, N; Tominaga, H; Aoki, K; Hasegawa, E; Idota, Y; Moriwaki, T
1998-09-01
The purpose of this study was to investigate the utility of an infrared tympanic thermometry by using an optical fiber for measuring tympanic temperature (Tty). In the head cooling and facial fanning tests during normothermia, right Tty measured by this method (infrared-Tty) and esophageal temperature (Tes) were not affected by decreased temple and forehead skin temperatures, suggesting that the infrared sensor in this system measured the infrared radiation from the tympanic membrane selectively. Eight male subjects took part in passive-heat-stress and progressive-exercise tests. No significant differences among infrared-Tty, the left Tty measured by thermistor (contact-Tty), and Tes were observed at rest or at the end of each experiment, and there was no significant difference in the increase in these core temperatures from rest to the end. Furthermore, there were no significant differences in the core temperature threshold at the onset of sweating and slope (the relationship of sweating rate vs. infrared-Tty and vs. contact-Tty). These results suggest that this method makes it possible to measure Tty accurately, continuously, and more safely.
2D versus 3D in the kinematic analysis of the horse at the trot.
Miró, F; Santos, R; Garrido-Castro, J L; Galisteo, A M; Medina-Carnicer, R
2009-08-01
The handled trot of three Lusitano Purebred stallions was analyzed by using 2D and 3D kinematical analysis methods. Using the same capture and analysis system, 2D and 3D data of some linear (stride length, maximal height of the hoof trajectories) and angular (angular range of motion, inclination of bone segments) variables were obtained. A paired Student T-test was performed in order to detect statistically significant differences between data resulting from the two methodologies With respect to the angular variables, there were significant differences in scapula inclination, shoulder angle, cannon inclination and protraction-retraction angle in the forelimb variables, but none of them were statistically different in the hind limb. Differences between the two methods were found in most of the linear variables analyzed.
Dhaliwal, J S; Malar, B; Quck, C K; Sukumaran, K D; Hassan, K
1991-06-01
Immunoperoxidase staining was compared with flowcytometry for the enumeration of lymphocyte subsets. The percentages obtained for peripheral blood lymphocytes using immunoperoxidase (CD3 = 76 CD4 = 27.9, B = 10.7 CD4/CD8 = 1.8) differed significantly from those obtained by flowcytometry (CD3 = 65.7 CD4 = 39.4, CD8 = 25.6, B = 16.7, HLA DR = 11.9 CD4/CD8 = 1.54) for certain subsets (CD3, CD4, B). There was no significant difference in lymphocyte subsets between children and adults using the same method. These differences are probably due to the different methods used to prepare lymphocytes for analysis. Other factors that should also be considered are the presence of CD4 antigen on monocytes and CD8 on natural killer cells.
Cardoso, F C; Sears, W; LeBlanc, S J; Drackley, J K
2011-12-01
The objective of the study was to compare 3 methods for calculating the area under the curve (AUC) for plasma glucose and nonesterified fatty acids (NEFA) after an intravenous epinephrine (EPI) challenge in dairy cows. Cows were assigned to 1 of 6 dietary niacin treatments in a completely randomized 6 × 6 Latin square with an extra period to measure carryover effects. Periods consisted of a 7-d (d 1 to 7) adaptation period followed by a 7-d (d 8 to 14) measurement period. On d 12, cows received an i.v. infusion of EPI (1.4 μg/kg of BW). Blood was sampled at -45, -30, -20, -10, and -5 min before EPI infusion and 2.5, 5, 10, 15, 20, 30, 45, 60, 90, and 120 min after. The AUC was calculated by incremental area, positive incremental area, and total area using the trapezoidal rule. The 3 methods resulted in different statistical inferences. When comparing the 3 methods for NEFA and glucose response, no significant differences among treatments and no interactions between treatment and AUC method were observed. For glucose and NEFA response, the method was statistically significant. Our results suggest that the positive incremental method and the total area method gave similar results and interpretation but differed from the incremental area method. Furthermore, the 3 methods evaluated can lead to different results and statistical inferences for glucose and NEFA AUC after an EPI challenge. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Tooth-size discrepancy: A comparison between manual and digital methods
Correia, Gabriele Dória Cabral; Habib, Fernando Antonio Lima; Vogel, Carlos Jorge
2014-01-01
Introduction Technological advances in Dentistry have emerged primarily in the area of diagnostic tools. One example is the 3D scanner, which can transform plaster models into three-dimensional digital models. Objective This study aimed to assess the reliability of tooth size-arch length discrepancy analysis measurements performed on three-dimensional digital models, and compare these measurements with those obtained from plaster models. Material and Methods To this end, plaster models of lower dental arches and their corresponding three-dimensional digital models acquired with a 3Shape R700T scanner were used. All of them had lower permanent dentition. Four different tooth size-arch length discrepancy calculations were performed on each model, two of which by manual methods using calipers and brass wire, and two by digital methods using linear measurements and parabolas. Results Data were statistically assessed using Friedman test and no statistically significant differences were found between the two methods (P > 0.05), except for values found by the linear digital method which revealed a slight, non-significant statistical difference. Conclusions Based on the results, it is reasonable to assert that any of these resources used by orthodontists to clinically assess tooth size-arch length discrepancy can be considered reliable. PMID:25279529
Tuğcu-Demiröz, Fatmanur; Gonzalez-Alvarez, Isabel; Gonzalez-Alvarez, Marta; Bermejo, Marival
2014-10-01
The aim of the present study was to develop a method for water flux reabsorption measurement in Doluisio's Perfusion Technique based on the use of phenol red as a non-absorbable marker and to validate it by comparison with gravimetric procedure. The compounds selected for the study were metoprolol, atenolol, cimetidine and cefadroxil in order to include low, intermediate and high permeability drugs absorbed by passive diffusion and by carrier mediated mechanism. The intestinal permeabilities (Peff) of the drugs were obtained in male and female Wistar rats and calculated using both methods of water flux correction. The absorption rate coefficients of all the assayed compounds did not show statistically significant differences between male and female rats consequently all the individual values were combined to compare between reabsorption methods. The absorption rate coefficients and permeability values did not show statistically significant differences between the two strategies of concentration correction. The apparent zero order water absorption coefficients were also similar in both correction procedures. In conclusion gravimetric and phenol red method for water reabsorption correction are accurate and interchangeable for permeability estimation in closed loop perfusion method. Copyright © 2014 Elsevier B.V. All rights reserved.
Teaching acute care nurses cognitive assessment using LOCFAS: what's the best method?
Flannery, J; Land, K
2001-02-01
The Levels of Cognitive Functioning Assessment Scale (LOCFAS) is a behavioral checklist used by nurses in the acute care setting to assess the level of cognitive functioning in severely brain-injured patients in the early post-trauma period. Previous research studies have supported the reliability and validity of LOCFAS. For LOCFAS to become a more firmly established method of cognitive assessment, nurses must become familiar with and proficient in the use of this instrument. The purpose of this study was to find the most effective method of instruction by comparing three methods: a self-directed manual, a teaching video, and a classroom presentation. Videotaped vignettes of actual brain-injured patients were presented at the end of each training session, and participants were required to categorize these videotaped patients by using LOCFAS. High levels of reliability were observed for both the self-directed manual group and the teaching video group, but an overall lower level of reliability was observed for the classroom presentation group. Examination of the accuracy of overall LOCFAS ratings revealed a significant difference for instructional groups; the accuracy of the classroom presentation group was significantly lower than that of either the self-directed manual group or the teaching video group. The three instructional groups also differed on the average accuracy of ratings of the individual behaviors; the accuracy of the classroom presentation group was significantly lower than that of the teaching video group, whereas the self-directed manual group fell in between. Nurses also rated the instructional methods across a number of evaluative dimensions on a 5-point Likert-type scale. Evaluative statements ranged from average to good, with no significant differences among instructional methods.
[Comparision of Different Methods of Area Measurement in Irregular Scar].
Ran, D; Li, W J; Sun, Q G; Li, J Q; Xia, Q
2016-10-01
To determine a measurement standard of irregular scar area by comparing the advantages and disadvantages of different measurement methods in measuring same irregular scar area. Irregular scar area was scanned by digital scanning and measured by coordinate reading method, AutoCAD pixel method, Photoshop lasso pixel method, Photoshop magic bar filled pixel method and Foxit PDF reading software, and some aspects of these methods such as measurement time, repeatability, whether could be recorded and whether could be traced were compared and analyzed. There was no significant difference in the scar areas by the measurement methods above. However, there was statistical difference in the measurement time and repeatability by one or multi performers and only Foxit PDF reading software could be traced back. The methods above can be used for measuring scar area, but each one has its advantages and disadvantages. It is necessary to develop new measurement software for forensic identification. Copyright© by the Editorial Department of Journal of Forensic Medicine
Shimizu, Hironori; Isoda, Hiroyoshi; Ohno, Tsuyoshi; Yamashita, Rikiya; Kawahara, Seiya; Furuta, Akihiro; Fujimoto, Koji; Kido, Aki; Kusahara, Hiroshi; Togashi, Kaori
2015-01-01
To compare and evaluate images of non-contrast enhanced magnetic resonance (MR) portography and hepatic venography acquired with two different fat suppression methods, the chemical shift selective (CHESS) method and short tau inversion recovery (STIR) method. Twenty-two healthy volunteers were examined using respiratory-triggered three-dimensional true steady-state free-precession with two time-spatial labeling inversion pulses. The CHESS or STIR methods were used for fat suppression. The relative signal-to-noise ratio and contrast-to-noise ratio (CNR) were quantified, and the quality of visualization was scored. Image acquisition was successfully conducted in all volunteers. The STIR method significantly improved the CNRs of MR portography and hepatic venography. The image quality scores of main portal vein and right portal vein were higher with the STIR method, but there were no significant differences. The image quality scores of right hepatic vein, middle hepatic vein, and left hepatic vein (LHV) were all higher, and the visualization of LHV was significantly better (p<0.05). The STIR method contributes to further suppression of the background signal and improves visualization of the portal and hepatic veins. The results support using non-contrast-enhanced MR portography and hepatic venography in clinical practice. Copyright © 2014 Elsevier Inc. All rights reserved.
Feng, Yong; Chen, Aiqing
2017-01-01
This study aimed to quantify blood pressure (BP) measurement accuracy and variability with different techniques. Thirty video clips of BP recordings from the BHS training database were converted to Korotkoff sound waveforms. Ten observers without receiving medical training were asked to determine BPs using (a) traditional manual auscultatory method and (b) visual auscultation method by visualizing the Korotkoff sound waveform, which was repeated three times on different days. The measurement error was calculated against the reference answers, and the measurement variability was calculated from the SD of the three repeats. Statistical analysis showed that, in comparison with the auscultatory method, visual method significantly reduced overall variability from 2.2 to 1.1 mmHg for SBP and from 1.9 to 0.9 mmHg for DBP (both p < 0.001). It also showed that BP measurement errors were significant for both techniques (all p < 0.01, except DBP from the traditional method). Although significant, the overall mean errors were small (−1.5 and −1.2 mmHg for SBP and −0.7 and 2.6 mmHg for DBP, resp., from the traditional auscultatory and visual auscultation methods). In conclusion, the visual auscultation method had the ability to achieve an acceptable degree of BP measurement accuracy, with smaller variability in comparison with the traditional auscultatory method. PMID:29423405
Moon, Sung Sil
2014-01-01
This study investigated the effects of cooking methods on the digestibility of lipids and formation of cholesterol oxidation products (COPs) in pork, during in vitro human digestion. Pork patties were cooked using four different methods (oven cooking, pan frying, boiling, and microwaving), to an internal temperature of approximately 85℃. The digestibility of pork patties were then evaluated, using the in vitro human digestion model that simulated the composition (pH, minerals, surfaceactive components, and enzymes) of digestive juices in the human mouth, stomach, and small intestine. The total lipid digestibility was higher after microwave cooking, whereas pan-frying resulted in lower in vitro digestibility, compared to the other cooking methods. The microwaving method followed by in vitro digestion also showed significantly higher content of free fatty acids and thiobarbituric acid reactive substances (TBARS), compared to the other cooking methods; whereas, the pan frying and boiling methods showed the lowest. Cholesterol content was not significantly different among the cooked samples before, and after in vitro human digestion. The formation of COPs was significantly higher in the microwave-treated pork samples, compared to those cooked by the other methods, which was consistent with the trend for lipid peroxidation (TBARS). We propose that from the point of view of COPs formation and lipid oxidation, the pan-frying or boiling methods would be useful. PMID:26761168
A standardised protocol for texture feature analysis of endoscopic images in gynaecological cancer.
Neofytou, Marios S; Tanos, Vasilis; Pattichis, Marios S; Pattichis, Constantinos S; Kyriacou, Efthyvoulos C; Koutsouris, Dimitris D
2007-11-29
In the development of tissue classification methods, classifiers rely on significant differences between texture features extracted from normal and abnormal regions. Yet, significant differences can arise due to variations in the image acquisition method. For endoscopic imaging of the endometrium, we propose a standardized image acquisition protocol to eliminate significant statistical differences due to variations in: (i) the distance from the tissue (panoramic vs close up), (ii) difference in viewing angles and (iii) color correction. We investigate texture feature variability for a variety of targets encountered in clinical endoscopy. All images were captured at clinically optimum illumination and focus using 720 x 576 pixels and 24 bits color for: (i) a variety of testing targets from a color palette with a known color distribution, (ii) different viewing angles, (iv) two different distances from a calf endometrial and from a chicken cavity. Also, human images from the endometrium were captured and analysed. For texture feature analysis, three different sets were considered: (i) Statistical Features (SF), (ii) Spatial Gray Level Dependence Matrices (SGLDM), and (iii) Gray Level Difference Statistics (GLDS). All images were gamma corrected and the extracted texture feature values were compared against the texture feature values extracted from the uncorrected images. Statistical tests were applied to compare images from different viewing conditions so as to determine any significant differences. For the proposed acquisition procedure, results indicate that there is no significant difference in texture features between the panoramic and close up views and between angles. For a calibrated target image, gamma correction provided an acquired image that was a significantly better approximation to the original target image. In turn, this implies that the texture features extracted from the corrected images provided for better approximations to the original images. Within the proposed protocol, for human ROIs, we have found that there is a large number of texture features that showed significant differences between normal and abnormal endometrium. This study provides a standardized protocol for avoiding any significant texture feature differences that may arise due to variability in the acquisition procedure or the lack of color correction. After applying the protocol, we have found that significant differences in texture features will only be due to the fact that the features were extracted from different types of tissue (normal vs abnormal).
SU-E-I-08: Investigation of Deconvolution Methods for Blocker-Based CBCT Scatter Estimation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhao, C; Jin, M; Ouyang, L
2015-06-15
Purpose: To investigate whether deconvolution methods can improve the scatter estimation under different blurring and noise conditions for blocker-based scatter correction methods for cone-beam X-ray computed tomography (CBCT). Methods: An “ideal” projection image with scatter was first simulated for blocker-based CBCT data acquisition by assuming no blurring effect and no noise. The ideal image was then convolved with long-tail point spread functions (PSF) with different widths to mimic the blurring effect from the finite focal spot and detector response. Different levels of noise were also added. Three deconvolution Methods: 1) inverse filtering; 2) Wiener; and 3) Richardson-Lucy, were used tomore » recover the scatter signal in the blocked region. The root mean square error (RMSE) of estimated scatter serves as a quantitative measure for the performance of different methods under different blurring and noise conditions. Results: Due to the blurring effect, the scatter signal in the blocked region is contaminated by the primary signal in the unblocked region. The direct use of the signal in the blocked region to estimate scatter (“direct method”) leads to large RMSE values, which increase with the increased width of PSF and increased noise. The inverse filtering is very sensitive to noise and practically useless. The Wiener and Richardson-Lucy deconvolution methods significantly improve scatter estimation compared to the direct method. For a typical medium PSF and medium noise condition, both methods (∼20 RMSE) can achieve 4-fold improvement over the direct method (∼80 RMSE). The Wiener method deals better with large noise and Richardson-Lucy works better on wide PSF. Conclusion: We investigated several deconvolution methods to recover the scatter signal in the blocked region for blocker-based scatter correction for CBCT. Our simulation results demonstrate that Wiener and Richardson-Lucy deconvolution can significantly improve the scatter estimation compared to the direct method.« less
Environmental justice assessment for transportation : risk analysis
DOT National Transportation Integrated Search
1999-04-01
This paper presents methods of comparing populations and their racial/ethnic compositions using tabulations, histograms, and Chi Squared tests for statistical significance of differences found. Two examples of these methods are presented: comparison ...
NASA Astrophysics Data System (ADS)
Hurst March, Robin Denise
This investigation compared student achievement and attitudes toward science from three different sequencing approaches used in teaching biology to nonscience students. The three sequencing approaches were the lecture course only, lecture/laboratory courses taken together, and laboratory with previously taken lecture approach. The purposes of this study were to determine if (1) a relationship exists between the Attitude Towards Science in School Assessment (ATSSA) scores (Germann, 1988) and biology achievement, (2) a difference exists among the ATSSA scores and sequencing, (3) a difference exists among the biology achievement scores and sequencing, and (4) the ATSSA is a reliable instrument of science attitude assessment for the undergraduate students in an introductory biology nonmajors laboratory and lecture courses at a research I institution during the fall semester 1996. Fifty-four students comprised the lecture only group, 90 students comprised the lecture and laboratory taken together approach, and 23 students comprised the laboratory only approach. Research questions addressed were (1) What are the differences in student biology achievement as a function of the three different methods of instruction? (2) What are the differences in student attitude towards science as a function of the three different methods of instruction? (3) What is the relationship between post-attitude (ATSSA) and biology achievement for each of the three methods of instruction? An analysis of variance utilized the mean posttest scores on the ATSSA and mean achievement scores as the dependent variables. The independent variables were the three different sequences of enrollment in introductory biology. At the.05 level of significance, it was found that no significant difference existed between the ATTS and laboratory/lecture sequence. At the.05 level of significance, it was found that no significant difference existed between achievement and laboratory/lecture sequence. A Pearson product moment correlation was used to see if a relationship existed between posttest ATSSA scores and achievement totals in each sequence. A significant relationship was noted between the ATSSA and achievement in each sequence that involved a laboratory component.
Gibby, Jacob T; Njeru, Dennis K; Cvetko, Steve T; Heiny, Eric L; Creer, Andrew R; Gibby, Wendell A
We correlate and evaluate the accuracy of accepted anthropometric methods of percent body fat (%BF) quantification, namely, hydrostatic weighing (HW) and air displacement plethysmography (ADP), to 2 automatic adipose tissue quantification methods using computed tomography (CT). Twenty volunteer subjects (14 men, 6 women) received head-to-toe CT scans. Hydrostatic weighing and ADP were obtained from 17 and 12 subjects, respectively. The CT data underwent conversion using 2 separate algorithms, namely, the Schneider method and the Beam method, to convert Hounsfield units to their respective tissue densities. The overall mass and %BF of both methods were compared with HW and ADP. When comparing ADP to CT data using the Schneider method and Beam method, correlations were r = 0.9806 and 0.9804, respectively. Paired t tests indicated there were no statistically significant biases. Additionally, observed average differences in %BF between ADP and the Schneider method and the Beam method were 0.38% and 0.77%, respectively. The %BF measured from ADP, the Schneider method, and the Beam method all had significantly higher mean differences when compared with HW (3.05%, 2.32%, and 1.94%, respectively). We have shown that total body mass correlates remarkably well with both the Schneider method and Beam method of mass quantification. Furthermore, %BF calculated with the Schneider method and Beam method CT algorithms correlates remarkably well with ADP. The application of these CT algorithms have utility in further research to accurately stratify risk factors with periorgan, visceral, and subcutaneous types of adipose tissue, and has the potential for significant clinical application.
NASA Astrophysics Data System (ADS)
Riad, Safaa M.; Salem, Hesham; Elbalkiny, Heba T.; Khattab, Fatma I.
2015-04-01
Five, accurate, precise, and sensitive univariate and multivariate spectrophotometric methods were developed for the simultaneous determination of a ternary mixture containing Trimethoprim (TMP), Sulphamethoxazole (SMZ) and Oxytetracycline (OTC) in waste water samples collected from different cites either production wastewater or livestock wastewater after their solid phase extraction using OASIS HLB cartridges. In univariate methods OTC was determined at its λmax 355.7 nm (0D), while (TMP) and (SMZ) were determined by three different univariate methods. Method (A) is based on successive spectrophotometric resolution technique (SSRT). The technique starts with the ratio subtraction method followed by ratio difference method for determination of TMP and SMZ. Method (B) is successive derivative ratio technique (SDR). Method (C) is mean centering of the ratio spectra (MCR). The developed multivariate methods are principle component regression (PCR) and partial least squares (PLS). The specificity of the developed methods is investigated by analyzing laboratory prepared mixtures containing different ratios of the three drugs. The obtained results are statistically compared with those obtained by the official methods, showing no significant difference with respect to accuracy and precision at p = 0.05.
Riad, Safaa M; Salem, Hesham; Elbalkiny, Heba T; Khattab, Fatma I
2015-04-05
Five, accurate, precise, and sensitive univariate and multivariate spectrophotometric methods were developed for the simultaneous determination of a ternary mixture containing Trimethoprim (TMP), Sulphamethoxazole (SMZ) and Oxytetracycline (OTC) in waste water samples collected from different cites either production wastewater or livestock wastewater after their solid phase extraction using OASIS HLB cartridges. In univariate methods OTC was determined at its λmax 355.7 nm (0D), while (TMP) and (SMZ) were determined by three different univariate methods. Method (A) is based on successive spectrophotometric resolution technique (SSRT). The technique starts with the ratio subtraction method followed by ratio difference method for determination of TMP and SMZ. Method (B) is successive derivative ratio technique (SDR). Method (C) is mean centering of the ratio spectra (MCR). The developed multivariate methods are principle component regression (PCR) and partial least squares (PLS). The specificity of the developed methods is investigated by analyzing laboratory prepared mixtures containing different ratios of the three drugs. The obtained results are statistically compared with those obtained by the official methods, showing no significant difference with respect to accuracy and precision at p=0.05. Copyright © 2015 Elsevier B.V. All rights reserved.
Lin, Hai-jun; Zhang, Hui-fang; Gao, Ya-qi; Li, Xia; Yang, Fan; Zhou, Yan-fei
2014-12-01
The hyperspectral reflectance of Populus euphratica, Tamarix hispida, Haloxylon ammodendron and Calligonum mongolicum in the lower reaches of Tarim River and Turpan Desert Botanical Garden was measured by using the HR-768 field-portable spectroradiometer. The method of continuum removal, first derivative reflectance and second derivative reflectance were used to deal with the original spectral data of four tree species. The method of Mahalanobis Distance was used to select the bands with significant differences in the original spectral data and transform spectral data to identify the different tree species. The progressive discrimination analyses were used to test the selective bands used to identify different tree species. The results showed that The Mahalanobis Distance method was an effective method in feature band extraction. The bands for identifying different tree species were most near-infrared bands. The recognition accuracy of four methods was 85%, 93.8%, 92.4% and 95.5% respectively. Spectrum transform could improve the recognition accuracy. The recognition accuracy of different research objects and different spectrum transform methods were different. The research provided evidence for desert tree species classification, monitoring biodiversity and the analysis of area in desert by using large scale remote sensing method.
Feng, Cheng; Chen, Lixin; Li, Jian; Wang, Jiangtao; Dong, Fajin; Xu, Jinfeng
2017-01-01
To compare a full-automated software to quantify 3D transthoracic echocardiography namely, 3DE-HM (three-dimensional echocardiography HeartModel, Philips Healthcare) with the traditional manual quantitative method (3DE-manual) for assessing volumes of left atrial and ventricular volumes, and left ventricular ejection fraction (LVEF). 3D full volume images acquired from 156 subjects were collected and divided into 3 groups, which include 70 normal control cases (Group A), 17 patients with left ventricular remodeling after acute myocardial infarction (AMI) (Group B), and 69 patients with left atrial remodeling secondary to hypertension (Group C). The 3DE-HM method was used to quantify left ventricular end-diastolic volume (LVEDV), left ventricular end-systolic volume (LVESV), left atrial end-systolic volume (LAESV), and left ventricular ejection fraction (LVEF), respectively. The results were compared with those obtained with the 3DE-manual method for correlation and consistency analyses. The reproducibility of the 3DE-HM method was also evaluated. There was a high correlation between LVEDV, LVESV, LAESV and LVEF values obtained with the 3DE-HM method and those obtained using the 3DE-manual method (r = 0.72 to 0.97). The correlation was strongest for Group B, patients with left ventricular remodeling post-AMI also demonstrated the greatest degree of morphologic changes. There was a significant difference in all parameters measured with the 3DE-HM method in different groups (P < 0.05). The difference in the measurements of LVEDV and LVESV between the two methods was greatest in patients in Group B compared with patients with hypertension-induced left ventricular remodeling (Group C) and in normal controls (Group A) (P < 0.05). Lastly, the difference in the measurement of LAESV between the two methods was greater in patients with hypertension-induced left ventricular remodeling (Group C) than that in the control group (Group A) (P < 0.05). The post-processing time of the 3DE-HM data was significantly shorter than that using the 3DE-manual method (P < 0.05). There was no significant variability in repeated measurements at different time points using the 3DE-HM method either between subjects in different groups or within the same subject. 3DE-HM is a quick and feasible method for left ventricular quantification and is clinically applicable for evaluating patients with left atrial and left ventricular remodeling.
Mueller, Sherry A; Anderson, James E; Kim, Byung R; Ball, James C
2009-04-01
Effective bacterial control in cooling-tower systems requires accurate and timely methods to count bacteria. Plate-count methods are difficult to implement on-site, because they are time- and labor-intensive and require sterile techniques. Several field-applicable methods (dipslides, Petrifilm, and adenosine triphosphate [ATP] bioluminescence) were compared with the plate count for two sample matrices--phosphate-buffered saline solution containing a pure culture of Pseudomonas fluorescens and cooling-tower water containing an undefined mixed bacterial culture. For the pure culture, (1) counts determined on nutrient agar and plate-count agar (PCA) media and expressed as colony-forming units (CFU) per milliliter were equivalent to those on R2A medium (p = 1.0 and p = 1.0, respectively); (2) Petrifilm counts were not significantly different from R2A plate counts (p = 0.99); (3) the dipslide counts were up to 2 log units higher than R2A plate counts, but this discrepancy was not statistically significant (p = 0.06); and (4) a discernable correlation (r2 = 0.67) existed between ATP readings and plate counts. For cooling-tower water samples (n = 62), (1) bacterial counts using R2A medium were higher (but not significant; p = 0.63) than nutrient agar and significantly higher than tryptone-glucose yeast extract (TGE; p = 0.03) and PCA (p < 0.001); (2) Petrifilm counts were significantly lower than nutrient agar or R2A (p = 0.02 and p < 0.001, respectively), but not statistically different from TGE, PCA, and dipslides (p = 0.55, p = 0.69, and p = 0.91, respectively); (3) the dipslide method yielded bacteria counts 1 to 3 log units lower than nutrient agar and R2A (p < 0.001), but was not significantly different from Petrifilm (p = 0.91), PCA (p = 1.00) or TGE (p = 0.07); (4) the differences between dipslides and the other methods became greater with a 6-day incubation time; and (5) the correlation between ATP readings and plate counts varied from system to system, was poor (r2 values ranged from < 0.01 to 0.47), and the ATP method was not sufficiently sensitive to measure counts below approximately 10(4) CFU/mL.
Evaluation of three miniature radio transmitter attachment methods for small passerines
Sykes, P.W.; Carpenter, J.W.; Holzman, S.; Geissler, P.H.
1990-01-01
Thirty-two immature common yellowthroats were used to evaluate three methods of attaching radio transmitters to the backs of small passerines: adhesive, velcro, and harness. There were no significant differences between the three methods; however, the adhesive method of transmitter attachment to small birds was found to be the preferred technique.
Salwe, Sukeshani; Kothari, Sweta; Chowdhary, Abhay; Deshmukh, Ranjana A.
2018-01-01
12–14 days of culturing of bone marrow (BM) cells containing various growth factors is widely used method for generating dendritic cells (DCs) from suspended cell population. Here we compared flask culture method and commercially available CD11c Positive Selection kit method. Immature BMDCs' purity of adherent as well as suspended cell population was generated in the decreasing concentration of recombinant-murine granulocyte-macrophage colony-stimulating factor (rmGM-CSF) in nontreated tissue culture flasks. The expression of CD11c, MHCII, CD40, and CD86 was measured by flow cytometry. We found significant difference (P < 0.05) between the two methods in the adherent cells population but no significant difference was observed between the suspended cell populations with respect to CD11c+ count. However, CD11c+ was significantly higher in both adhered and suspended cell population by culture method but kit method gave more CD11c+ from suspended cells population only. On the other hand, using both methods, immature DC expressed moderate level of MHC class II molecules as well as low levels of CD40 and CD86. Our findings suggest that widely used culture method gives the best results in terms of yield, viability, and purity of BMDCs from both adherent and suspended cell population whereas kit method works well for suspended cell population. PMID:29682352
Gosavi, Rahul Ashok; Salwe, Sukeshani; Mukherjee, Sandeepan; Dahake, Ritwik; Kothari, Sweta; Patel, Vainav; Chowdhary, Abhay; Deshmukh, Ranjana A
2018-01-01
12-14 days of culturing of bone marrow (BM) cells containing various growth factors is widely used method for generating dendritic cells (DCs) from suspended cell population. Here we compared flask culture method and commercially available CD11c Positive Selection kit method. Immature BMDCs' purity of adherent as well as suspended cell population was generated in the decreasing concentration of recombinant-murine granulocyte-macrophage colony-stimulating factor (rmGM-CSF) in nontreated tissue culture flasks. The expression of CD11c, MHCII, CD40, and CD86 was measured by flow cytometry. We found significant difference ( P < 0.05) between the two methods in the adherent cells population but no significant difference was observed between the suspended cell populations with respect to CD11c+ count. However, CD11c+ was significantly higher in both adhered and suspended cell population by culture method but kit method gave more CD11c+ from suspended cells population only. On the other hand, using both methods, immature DC expressed moderate level of MHC class II molecules as well as low levels of CD40 and CD86. Our findings suggest that widely used culture method gives the best results in terms of yield, viability, and purity of BMDCs from both adherent and suspended cell population whereas kit method works well for suspended cell population.
Walker, Jean T; Martin, Tina M; Haynie, Lisa; Norwood, Anne; White, Jill; Grant, LaVerne
2007-01-01
Accelerated baccalaureate nursing programs are in great demand in the United States. Currently there are 197 such programs, but little research has been conducted on student characteristics and program outcomes. This quantitative study explores preferences of second-degree students and traditional generic students with regard to teaching methods and relationships with faculty. The results indicate that statistically significant differences exist between the two groups of students. Three areas of significance are ability for self-directed learning, expectations of faculty and classroom structure, and obtaining a grade that really matters.
Validity of three clinical performance assessments of internal medicine clerks.
Hull, A L; Hodder, S; Berger, B; Ginsberg, D; Lindheim, N; Quan, J; Kleinhenz, M E
1995-06-01
To analyze the construct validity of three methods to assess the clinical performances of internal medicine clerks. A multitrait-multimethod (MTMM) study was conducted at the Case Western Reserve University School of Medicine to determine the convergent and divergent validity of a clinical evaluation form (CEF) completed by faculty and residents, an objective structured clinical examination (OSCE), and the medicine subject test of the National Board of Medical Examiners. Three traits were involved in the analysis: clinical skills, knowledge, and personal characteristics. A correlation matrix was computed for 410 third-year students who completed the clerkship between August 1988 and July 1991. There was a significant (p < .01) convergence of the four correlations that assessed the same traits by using different methods. However, the four convergent correlations were of moderate magnitude (ranging from .29 to .47). Divergent validity was assessed by comparing the magnitudes of the convergence correlations with the magnitudes of correlations among unrelated assessments (i.e., different traits by different methods). Seven of nine possible coefficients were smaller than the convergent coefficients, suggesting evidence of divergent validity. A significant CEF method effect was identified. There was convergent validity and some evidence of divergent validity with a significant method effect. The findings were similar for correlations corrected for attenuation. Four conclusions were reached: (1) the reliability of the OSCE must be improved, (2) the CEF ratings must be redesigned to further discriminate among the specific traits assessed, (3) additional methods to assess personal characteristics must be instituted, and (4) several assessment methods should be used to evaluate individual student performances.
Comparison of Instream and Laboratory Methods of Measuring Sediment Oxygen Demand
Hall, Dennis C.; Berkas, Wayne R.
1988-01-01
Sediment oxygen demand (SOD) was determined at three sites in a gravel-bottomed central Missouri stream by: (1) two variations of an instream method, and (2) a laboratory method. SOD generally was greatest by the instream methods, which are considered more accurate, and least by the laboratory method. Disturbing stream sediment did not significantly decrease SOD by the instream method. Temperature ranges of up to 12 degree Celsius had no significant effect on the SOD. In the gravel-bottomed stream, the placement of chambers was critical to obtain reliable measurements. SOD rates were dependent on the method; therefore, care should be taken in comparing SOD data obtained by different methods. There is a need for a carefully researched standardized method for SOD determinations.
Stability of vitamin D3 and vitamin D2 in oil, fish and mushrooms after household cooking.
Ložnjak, Petra; Jakobsen, Jette
2018-07-15
Information on the retention of vitamin D in food following household cooking is scarce. So far the retention of its metabolites vitamin D 3 , vitamin D 2 , and 25-hydroxyvitamin D 3 has shown that the type of food and the cooking method are the essential determinants, and there is no significant difference between the metabolites. We investigated the retention of vitamin D 3 and vitamin D 2 in sunflower oil, vitamin D 3 in rainbow trout, and vitamin D 2 in button mushrooms. The investigated cooking methods were boiling at different pH, steam cooking, microwave cooking, pan-frying, and oven baking. There was no difference between the retention of vitamin D 3 and vitamin D 2 added to sunflower oil, which ranged from 70 to 99%. In rainbow trout, the retention of vitamin D 3 at 85-114% was not significantly different from 100%, except for panfrying at 85%. However, the retention of vitamin D 2 in mushrooms at 62-88% was significantly different from 100% (p ≤ 0.05). Copyright © 2018 Elsevier Ltd. All rights reserved.
Khorrami, Mohammad Hatef; Izadpanahi, Mohammad Hossein; Mohammadi, Mehrdad; Alizadeh, Farshid; Zargham, Mahtab; Khorrami, Farbod; Isfahani, Felora Farahini
2017-01-01
Access dilation is the most important part of percutaneous nephrolithotripsy (PCNL) that is done by different methods, especially metal telescoping and one shot. In this study, two different methods of access dilation one shot and telescoping were compared. In observational cross-sectional study, 240 patients who were a candidate for PCNL were selected and randomly divided into two groups. The first group was undergone one-shot method and the second group was undergone telescoping method. The decrease in hemoglobin (Hb), duration of hospitalization and the time of radiation exposure during access dilation was compared in two groups by SPSS software version 21, (SPSS Inc., Chicago, IL, USA). The decrease of Hb level after intervention in one-shot group was 1.08 ± 1.23 g/dl and in telescoping, group was 1.51 ± 1.08 g/dl with no difference statistically ( P = 0.37). The mean duration of hospitalization in one shot and telescoping group were 2.36 ± 0.67 and 2.28 ± 0.61 days, respectively. According to t -test, there was no significant difference between the two groups ( P = 0.37). Average radiation exposure in one shot group was 7.13 s and in telescoping, group was 35.75 s, and there was a significant difference between the two groups ( P < 0.001). One-shot method is superior to telescoping method due to less time for radiation exposure and no more blood loss and other complications during PCNL.
Patrick, Thomas E.; Goodwin, T. L.; Collins, J. A.; Wyche, R. C.; Love, B. E.
1972-01-01
A comparison of two types of scalders was conducted to determine their effectiveness in reducing bacterial contamination of poultry carcasses. A conventional hot-water scalder and a prototype model of a steam scalder were tested under commercial conditions. Total plate counts from steam-scalded birds were significantly lower than the counts of water-scalded birds immediately after scalding and again after picking. No differences in the two methods could be found after chilling. Coliform counts from steam-scalded birds were significantly lower than the counts from water-scalded birds immediately after scalding. No significant differences in coliform counts were detected when the two scald methods were compared after defeathering and chilling. PMID:4553146
Farer, Leslie J; Hayes, John M
2005-01-01
A new method has been developed for the determination of emamectin benzoate in fish feed. The method uses a wet extraction, cleanup by solid-phase extraction, and quantitation and separation by liquid chromatography (LC). In this paper, we compare the performance of this method with that of a previously reported LC assay for the determination of emamectin benzoate in fish feed. Although similar to the previous method, the new procedure uses a different sample pretreatment, wet extraction, and quantitation method. The performance of the new method was compared with that of the previously reported method by analyses of 22 medicated feed samples from various commercial sources. A comparison of the results presented here reveals slightly lower assay values obtained with the new method. Although a paired sample t-test indicates the difference in results is significant, this difference is within the method precision of either procedure.
Guo, Xinyu; Dominick, Kelli C; Minai, Ali A; Li, Hailong; Erickson, Craig A; Lu, Long J
2017-01-01
The whole-brain functional connectivity (FC) pattern obtained from resting-state functional magnetic resonance imaging data are commonly applied to study neuropsychiatric conditions such as autism spectrum disorder (ASD) by using different machine learning models. Recent studies indicate that both hyper- and hypo- aberrant ASD-associated FCs were widely distributed throughout the entire brain rather than only in some specific brain regions. Deep neural networks (DNN) with multiple hidden layers have shown the ability to systematically extract lower-to-higher level information from high dimensional data across a series of neural hidden layers, significantly improving classification accuracy for such data. In this study, a DNN with a novel feature selection method (DNN-FS) is developed for the high dimensional whole-brain resting-state FC pattern classification of ASD patients vs. typical development (TD) controls. The feature selection method is able to help the DNN generate low dimensional high-quality representations of the whole-brain FC patterns by selecting features with high discriminating power from multiple trained sparse auto-encoders. For the comparison, a DNN without the feature selection method (DNN-woFS) is developed, and both of them are tested with different architectures (i.e., with different numbers of hidden layers/nodes). Results show that the best classification accuracy of 86.36% is generated by the DNN-FS approach with 3 hidden layers and 150 hidden nodes (3/150). Remarkably, DNN-FS outperforms DNN-woFS for all architectures studied. The most significant accuracy improvement was 9.09% with the 3/150 architecture. The method also outperforms other feature selection methods, e.g., two sample t -test and elastic net. In addition to improving the classification accuracy, a Fisher's score-based biomarker identification method based on the DNN is also developed, and used to identify 32 FCs related to ASD. These FCs come from or cross different pre-defined brain networks including the default-mode, cingulo-opercular, frontal-parietal, and cerebellum. Thirteen of them are statically significant between ASD and TD groups (two sample t -test p < 0.05) while 19 of them are not. The relationship between the statically significant FCs and the corresponding ASD behavior symptoms is discussed based on the literature and clinician's expert knowledge. Meanwhile, the potential reason of obtaining 19 FCs which are not statistically significant is also provided.
Chládek, J; Brázdil, M; Halámek, J; Plešinger, F; Jurák, P
2013-01-01
We present an off-line analysis procedure for exploring brain activity recorded from intra-cerebral electroencephalographic data (SEEG). The objective is to determine the statistical differences between different types of stimulations in the time-frequency domain. The procedure is based on computing relative signal power change and subsequent statistical analysis. An example of characteristic statistically significant event-related de/synchronization (ERD/ERS) detected across different frequency bands following different oddball stimuli is presented. The method is used for off-line functional classification of different brain areas.
Comparison of methods for estimating flood magnitudes on small streams in Georgia
Hess, Glen W.; Price, McGlone
1989-01-01
The U.S. Geological Survey has collected flood data for small, natural streams at many sites throughout Georgia during the past 20 years. Flood-frequency relations were developed for these data using four methods: (1) observed (log-Pearson Type III analysis) data, (2) rainfall-runoff model, (3) regional regression equations, and (4) map-model combination. The results of the latter three methods were compared to the analyses of the observed data in order to quantify the differences in the methods and determine if the differences are statistically significant.
Kawasaki, Yui; Akamatsu, Rie; Tamaura, Yuki; Sakai, Masashi; Fujiwara, Keiko; Tsutsuura, Satomi
2018-02-12
The aim of this study was to examine differences in the validity of a visual estimation method for determining patients' meal intake between various meal types and supplied food items in hospitals and to find factors influencing the validity of a visual estimation method. There are two procedures by which we obtained the information on dietary intake of the patients in these hospitals. These are both by visual assessment from the meal trays at the time of their clearing, by the attending nursing staff and by weighing conducted by researchers. The following criteria are set for the target trays: A) standard or therapeutic meals, which are monitored by a doctor, for energy and/or protein and/or sodium; B) regular, bite-sized, minced and pureed meal texture, and C) half-portion meals. Visual assessment results were tested for their validity by comparing with the corresponding results of weighing. Differences between these two methods indicated the estimated and absolute values of nutrient intake. A total of 255 (76.1%) trays were included in the analysis out of the 335 possible trays and the results indicated that the energy consumption estimates by visual or weighing procedures are not significantly different (412 ± 173 kcal, p = 0.15). However, the mean protein consumption was significantly different (16.3 ± 6.7 g/tray, p < 0.01) between the two procedures. Compared with standard meals (38 ± 45 kcal, 1.9 ± 2.5 g/tray), raters significantly misestimated the energy and protein intake of half-portion meals (78 ± 65 kcal, 2.8 ± 2.2 g/tray, p = 0.01) but accurately estimated the protein intake of protein controlled meals (0.5 ± 0.6 g/tray, p = 0.03). Trays adding supplied food items were significantly misestimated for energy intake (66 ± 58 kcal/tray) compared to trays with no additions (32 ± 39 kcal/tray, p < 0.01). Moreover, the results of multivariable analysis demonstrated that supplied food items were significantly associated with increased odds of a difference between the two methods (OR: 3.84; 95% confidence interval [CI]: 1.07-13.85). There were high correlations between the visual estimation method and the weighing method measuring patients' dietary intake for various meal types and textures, except for meals with added supplied food items. Nursing staff need to be attentive to supplied food items. Copyright © 2018 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
Yiin, Lih-Ming; Tian, Jia-Ni; Hung, Chien-Che
2015-05-01
Mutual enhancement of dermal absorption of N,N-diethyl-m-toluamide (DEET) and oxybenzone (OBZ) has been reported recently with DEET and OBZ being active ingredients of insect repellent and sunscreen, respectively. To assess the reported enhancing effect directly, we used human urinary metabolites as biomarkers; besides, we also sought to determine the best way for concurrent use of these two products without extra absorption of either. Four dermal application methods were used: DEET only (S1), OBZ only (S2), DEET on top of OBZ (S3), and OBZ on top of DEET (S4). Among the study methods, there was a significant difference (p = 0.013), which was attributed to the difference between S1 and S4, suggesting that applying OBZ over DEET on the skin lead to significantly higher absorption of DEET. Using both products in reverse order, (S3) did not result in extra DEET absorption significantly. As for OBZ permeation, no significant difference was observed among the methods. In summary, the enhancement of DEET absorption is confirmed for OBZ being applied over DEET on the skin; should concurrent use of both be necessary, applying sunscreen (OBZ) first and then insect repellent (DEET) with a 15-min interval is recommended.
Sa-ngasoongsong, Paphon; Chanplakorn, Pongsthorn; Wongsak, Siwadol; Uthadorn, Krisorn; Panpikoon, Tanapong; Jittorntam, Paisan; Aryurachai, Katcharin; Angchaisukisiri, Pantap; Kawinwonggowit, Viroj
2015-01-01
Recently, combined intra-articular tranexamic acid (IA-TXA) injection with clamping drain method showed efficacy for blood loss and transfusion reduction in total knee replacement (TKR). However, until now, none of previous studies revealed the effect of this technique on pharmacokinetics, coagulation, and fibrinolysis. An experimental study was conducted, during 2011-2012, in 30 patients undergoing unilateral TKR. Patients received IA-TXA application and then were allocated into six groups regarding clamping drain duration (2-, 4-, 6-, 8-, 10-, and 12-hours). Blood and drainage fluid were collected to measure tranexamic acid (TXA) level and related coagulation and fibrinolytic markers. Postoperative complication was followed for one year. There was no significant difference of serum TXA level at 2 hour and 24 hour among groups (p < 0.05). Serum TXA level at time of clamp release was significantly different among groups with the highest level at 2 hour (p < 0.0001). There was no significant difference of TXA level in drainage fluid, postoperative blood loss, blood transfusion, and postoperative complications (p < 0.05). Low-dose IA-TXA application in TKR with prolonged clamping drain method is a safe and effective blood conservative technique with only minimal systemic absorption and without significant increase in systemic absorption over time.
[Accuracy of three common optometry methods in examination of refraction in juveniles].
Su, Ting; Min, Xiaoshan; Liu, Shuangzhen; Li, Fengyun; Tan, Xingping; Zhong, Yanni; Deng, Shaoling
2016-02-01
To compare the results of the three methods of Suresight handheld autorefractor, table-mounted autorefractor and retinoscopy in examination of juveniles patients with or without cycloplegia. Firstly, 156 eyes of 78 juveniles (5 to 17 years old) were examined by using WelchAllyn Suresight handheld autorefractor and NIDEK ARK-510A table-mounted autorefractor with or without cycloplegia; secondly, retinoscopy was performed with cycloplegia. The spherical power measured by methods without cycloplegia were significantly greater than those measured with cycloplegia (P<0.05); without cycloplegia, there was no significant difference in spherical power, cylindrical power and cylindrical axis between Suresight handheld autorefractor and retinoscopy (P>0.05). These results were highly consistent, suggesting a tendency towards a short sight. However, the spherical power and cylindrical power measured by table-mounted autorefractor was significantly different (P<0.05); with cycloplegia, there was significant difference in spherical power between Suresight handheld autorefractor and retinoscopy (P<0.05). Cycloplegic retinoscopy is necessary for juvenile refraction examination. Under natural pupil situation, Suresight handheld autorefractor is better than table-mounted autorefractor, though both show a myopia tendency. Nevertheless, table-mounted autorefractor can be taken as a recommendation for the prescription of lens trial. As a strong reference for subjective optometry, retinoscopy should be the gold standard for measuring refractive errors.
Evaluation of nonrigid registration models for interfraction dose accumulation in radiotherapy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Janssens, Guillaume; Orban de Xivry, Jonathan; Fekkes, Stein
2009-09-15
Purpose: Interfraction dose accumulation is necessary to evaluate the dose distribution of an entire course of treatment by adding up multiple dose distributions of different treatment fractions. This accumulation of dose distributions is not straightforward as changes in the patient anatomy may occur during treatment. For this purpose, the accuracy of nonrigid registration methods is assessed for dose accumulation based on the calculated deformations fields. Methods: A phantom study using a deformable cubic silicon phantom with implanted markers and a cylindrical silicon phantom with MOSFET detectors has been performed. The phantoms were deformed and images were acquired using a cone-beammore » CT imager. Dose calculations were performed on these CT scans using the treatment planning system. Nonrigid CT-based registration was performed using two different methods, the Morphons and Demons. The resulting deformation field was applied on the dose distribution. For both phantoms, accuracy of the registered dose distribution was assessed. For the cylindrical phantom, also measured dose values in the deformed conditions were compared with the dose values of the registered dose distributions. Finally, interfraction dose accumulation for two treatment fractions of a patient with primary rectal cancer has been performed and evaluated using isodose lines and the dose volume histograms of the target volume and normal tissue. Results: A significant decrease in the difference in marker or MOSFET position was observed after nonrigid registration methods (p<0.001) for both phantoms and with both methods, as well as a significant decrease in the dose estimation error (p<0.01 for the cubic phantom and p<0.001 for the cylindrical) with both methods. Considering the whole data set at once, the difference between estimated and measured doses was also significantly decreased using registration (p<0.001 for both methods). The patient case showed a slightly underdosed planning target volume and an overdosed bladder volume due to anatomical deformations. Conclusions: Dose accumulation using nonrigid registration methods is possible using repeated CT imaging. This opens possibilities for interfraction dose accumulation and adaptive radiotherapy to incorporate possible differences in dose delivered to the target volume and organs at risk due to anatomical deformations.« less
Statistical Considerations of Data Processing in Giovanni Online Tool
NASA Technical Reports Server (NTRS)
Suhung, Shen; Leptoukh, G.; Acker, J.; Berrick, S.
2005-01-01
The GES DISC Interactive Online Visualization and Analysis Infrastructure (Giovanni) is a web-based interface for the rapid visualization and analysis of gridded data from a number of remote sensing instruments. The GES DISC currently employs several Giovanni instances to analyze various products, such as Ocean-Giovanni for ocean products from SeaWiFS and MODIS-Aqua; TOMS & OM1 Giovanni for atmospheric chemical trace gases from TOMS and OMI, and MOVAS for aerosols from MODIS, etc. (http://giovanni.gsfc.nasa.gov) Foremost among the Giovanni statistical functions is data averaging. Two aspects of this function are addressed here. The first deals with the accuracy of averaging gridded mapped products vs. averaging from the ungridded Level 2 data. Some mapped products contain mean values only; others contain additional statistics, such as number of pixels (NP) for each grid, standard deviation, etc. Since NP varies spatially and temporally, averaging with or without weighting by NP will be different. In this paper, we address differences of various weighting algorithms for some datasets utilized in Giovanni. The second aspect is related to different averaging methods affecting data quality and interpretation for data with non-normal distribution. The present study demonstrates results of different spatial averaging methods using gridded SeaWiFS Level 3 mapped monthly chlorophyll a data. Spatial averages were calculated using three different methods: arithmetic mean (AVG), geometric mean (GEO), and maximum likelihood estimator (MLE). Biogeochemical data, such as chlorophyll a, are usually considered to have a log-normal distribution. The study determined that differences between methods tend to increase with increasing size of a selected coastal area, with no significant differences in most open oceans. The GEO method consistently produces values lower than AVG and MLE. The AVG method produces values larger than MLE in some cases, but smaller in other cases. Further studies indicated that significant differences between AVG and MLE methods occurred in coastal areas where data have large spatial variations and a log-bimodal distribution instead of log-normal distribution.
Sales, A; Alvarez, A; Areal, M Rodriguez; Maldonado, L; Marchisio, P; Rodríguez, M; Bedascarrasbure, E
2006-10-11
Argentinean propolis is exported to different countries, specially Japan. The market demands propolis quality control according to international standards. The analytical determination of some metals, as lead in food, is very important for their high toxicity even in low concentrations and because of their harmful effects on health. Flavonoids, the main bioactive compounds of propolis, tend to chelate metals as lead, which becomes one of the main polluting agents of propolis. The lead found in propolis may come from the atmosphere or it may be incorporated in the harvest, extraction and processing methods. The aim of this work is to evaluate lead level on Argentinean propolis determined by electrothermal atomic absorption spectrometry (ET AAS) and UV-vis spectrophotometry (UV-visS) methods, as well as the effect of harvest methods on those contents. A randomized test with three different treatments of collection was made to evaluate the effect of harvest methods. These procedures were: separating wedges (traditional), netting plastic meshes and stamping out plastic meshes. By means of the analysis of variance technique for multiple comparisons (ANOVA) it was possible to conclude that there are significant differences between scraped and mesh methods (stamped out and mosquito netting meshes). The results obtained in the present test would allow us to conclude that mesh methods are more advisable than scraped ones in order to obtain innocuous and safe propolis with minor lead contents. A statistical comparison of lead determination by both, ET AAS and UV-visS methods, demonstrated that there is not a significant difference in the results achieved with the two analytical techniques employed.
Effects of Method of Instruction and Frequency of Response on Criterion Performance
ERIC Educational Resources Information Center
Troost, Cornelius J.; Morris, Stanley
1971-01-01
Grade six students were taught Newton's Second Law of Motion by a linear program, a lecture, or a video-taped lecture, with three different response modes: written responses to all questions, to one-third of the questions, or to no questions. There was no significant difference between teaching method, but the higher the overt response rate, the…
Quantifying the Thermal Fatigue of CPV Modules
NASA Astrophysics Data System (ADS)
Bosco, Nick; Kurtz, Sarah
2010-10-01
A method is presented to quantify thermal fatigue in the CPV die-attach from meteorological data. A comparative study between cities demonstrates a significant difference in the accumulated damage. These differences are most sensitive to the number of larger (ΔT) thermal cycles experienced for a location. High frequency data (<1/min) may be required to most accurately employ this method.
Douglas-fir seedlings planted by four methods...results after 10 years
R. O. Strothman
1976-01-01
Bare-root Douglas-fir seedlings were planted by four methods in late February and late March on a hot, south-facing slope in northwestern California. The four techniques were: standard planting, deep planting at two different depths, and shading of the lower stem. After 10 growing seasons, there were no significant differences in survival attributable to planting...
Sample entropy applied to the analysis of synthetic time series and tachograms
NASA Astrophysics Data System (ADS)
Muñoz-Diosdado, A.; Gálvez-Coyt, G. G.; Solís-Montufar, E.
2017-01-01
Entropy is a method of non-linear analysis that allows an estimate of the irregularity of a system, however, there are different types of computational entropy that were considered and tested in order to obtain one that would give an index of signals complexity taking into account the data number of the analysed time series, the computational resources demanded by the method, and the accuracy of the calculation. An algorithm for the generation of fractal time-series with a certain value of β was used for the characterization of the different entropy algorithms. We obtained a significant variation for most of the algorithms in terms of the series size, which could result counterproductive for the study of real signals of different lengths. The chosen method was sample entropy, which shows great independence of the series size. With this method, time series of heart interbeat intervals or tachograms of healthy subjects and patients with congestive heart failure were analysed. The calculation of sample entropy was carried out for 24-hour tachograms and time subseries of 6-hours for sleepiness and wakefulness. The comparison between the two populations shows a significant difference that is accentuated when the patient is sleeping.
Target volume and artifact evaluation of a new data-driven 4D CT.
Martin, Rachael; Pan, Tinsu
Four-dimensional computed tomography (4D CT) is often used to define the internal gross target volume (IGTV) for radiation therapy of lung cancer. Traditionally, this technique requires the use of an external motion surrogate; however, a new image, data-driven 4D CT, has become available. This study aims to describe this data-driven 4D CT and compare target contours created with it to those created using standard 4D CT. Cine CT data of 35 patients undergoing stereotactic body radiation therapy were collected and sorted into phases using standard and data-driven 4D CT. IGTV contours were drawn using a semiautomated method on maximum intensity projection images of both 4D CT methods. Errors resulting from reproducibility of the method were characterized. A comparison of phase image artifacts was made using a normalized cross-correlation method that assigned a score from +1 (data-driven "better") to -1 (standard "better"). The volume difference between the data-driven and standard IGTVs was not significant (data driven was 2.1 ± 1.0% smaller, P = .08). The Dice similarity coefficient showed good similarity between the contours (0.949 ± 0.006). The mean surface separation was 0.4 ± 0.1 mm and the Hausdorff distance was 3.1 ± 0.4 mm. An average artifact score of +0.37 indicated that the data-driven method had significantly fewer and/or less severe artifacts than the standard method (P = 1.5 × 10 -5 for difference from 0). On average, the difference between IGTVs derived from data-driven and standard 4D CT was not clinically relevant or statistically significant, suggesting data-driven 4D CT can be used in place of standard 4D CT without adjustments to IGTVs. The relatively large differences in some patients were usually attributed to limitations in automatic contouring or differences in artifacts. Artifact reduction and setup simplicity suggest a clinical advantage to data-driven 4D CT. Published by Elsevier Inc.
In vitro study of transverse strength of fiber reinforced composites.
Mosharraf, R; Hashemi, Z; Torkan, S
2011-01-01
Reinforcement with fiber is an effective method for considerable improvement in flexural properties of indirect composite resin restorations. The aim of this in-vitro study was to compare the transverse strength of composite resin bars reinforced with pre-impregnated and non-impregnated fibers. Thirty six bar type composite resin specimens (3×2×25 mm) were constructed in three groups. The first group was the control group (C) without any fiber reinforcement. The specimens in the second group (P) were reinforced with pre-impregnated fibers and the third group (N) with non-impregnated fibers. These specimens were tested by the three-point bending method to measure primary transverse strength. Data were statistically analyzed with one way ANOVA and Tukey's tests. There was a significant difference among the mean primary transverse strength in the three groups (P<0.001). The post-hoc (Tukey) test showed that there was a significant difference between the pre-impregnated and control groups in their primary transverse strength (P<0.001). Regarding deflection, there was also a significant difference among the three groups (P=0.001). There were significant differences among the mean deflection of the control group and two other groups (P(C&N)<.001 and P(C&P)=.004), but there was no significant difference between the non-and pre-impregnated groups (P(N&P)=.813). Within the limitations of this study, it was concluded that reinforcement with fiber considerably increased the transverse strength of composite resin specimens, but impregnation of the fiber used implemented no significant difference in the transverse strength of composite resin samples.
Paroxysmal atrial fibrillation prediction method with shorter HRV sequences.
Boon, K H; Khalil-Hani, M; Malarvili, M B; Sia, C W
2016-10-01
This paper proposes a method that predicts the onset of paroxysmal atrial fibrillation (PAF), using heart rate variability (HRV) segments that are shorter than those applied in existing methods, while maintaining good prediction accuracy. PAF is a common cardiac arrhythmia that increases the health risk of a patient, and the development of an accurate predictor of the onset of PAF is clinical important because it increases the possibility to stabilize (electrically) and prevent the onset of atrial arrhythmias with different pacing techniques. We investigate the effect of HRV features extracted from different lengths of HRV segments prior to PAF onset with the proposed PAF prediction method. The pre-processing stage of the predictor includes QRS detection, HRV quantification and ectopic beat correction. Time-domain, frequency-domain, non-linear and bispectrum features are then extracted from the quantified HRV. In the feature selection, the HRV feature set and classifier parameters are optimized simultaneously using an optimization procedure based on genetic algorithm (GA). Both full feature set and statistically significant feature subset are optimized by GA respectively. For the statistically significant feature subset, Mann-Whitney U test is used to filter non-statistical significance features that cannot pass the statistical test at 20% significant level. The final stage of our predictor is the classifier that is based on support vector machine (SVM). A 10-fold cross-validation is applied in performance evaluation, and the proposed method achieves 79.3% prediction accuracy using 15-minutes HRV segment. This accuracy is comparable to that achieved by existing methods that use 30-minutes HRV segments, most of which achieves accuracy of around 80%. More importantly, our method significantly outperforms those that applied segments shorter than 30 minutes. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Bock, Jens Johannes; Fraenzel, Wolfgang; Bailly, Jacqueline; Gernhardt, Christian Ralf; Fuhrmann, Robert Andreas Werner
2008-08-01
The aim of this study was to compare the mechanical strength and microhardness of joints made by conventional brazing and tungsten inert gas (TIG) and laser welding. A standardized end-to-end joint configuration of the orthodontic wire material in spring hard quality was used. The joints were made using five different methods: brazing (soldering > 450 degrees C) with universal silver solder, two TIG, and two laser welders. Laser parameters and welding conditions were used according to the manufacturers' guidance. The tensile strengths were measured with a universal testing machine (Zwick 005). The microhardness measurements were carried out with a hardness tester (Zwick 3202). Data were analysed using one-way analysis of variance and Bonferroni's post hoc correction (P < 0.05). In all cases, brazing joints ruptured at low levels of tensile strength (198 +/- 146 MPa). Significant differences (P < 0.001) between brazing and TIG or laser welding were found. The highest means were observed for TIG welding (699-754 MPa). Laser welding showed a significantly lower mean tensile strength (369-520 MPa) compared with TIG welding. Significant differences (P < 0.001) were found between the original orthodontic wire and the mean microhardness at the centre of the welded area. The mean microhardness differed significantly between brazing (1.99 GPa), TIG (2.22-2.39 GPa) and laser welding (2.21-2.68 GPa). For orthodontic purposes, laser and TIG welding are solder-free alternatives to joining metal. TIG welding with a lower investment cost is comparable with laser welding. However, while expensive, the laser technique is a sophisticated and simple method.
A psychophysical comparison of two methods for adaptive histogram equalization.
Zimmerman, J B; Cousins, S B; Hartzell, K M; Frisse, M E; Kahn, M G
1989-05-01
Adaptive histogram equalization (AHE) is a method for adaptive contrast enhancement of digital images. It is an automatic, reproducible method for the simultaneous viewing of contrast within a digital image with a large dynamic range. Recent experiments have shown that in specific cases, there is no significant difference in the ability of AHE and linear intensity windowing to display gray-scale contrast. More recently, a variant of AHE which limits the allowed contrast enhancement of the image has been proposed. This contrast-limited adaptive histogram equalization (CLAHE) produces images in which the noise content of an image is not excessively enhanced, but in which sufficient contrast is provided for the visualization of structures within the image. Images processed with CLAHE have a more natural appearance and facilitate the comparison of different areas of an image. However, the reduced contrast enhancement of CLAHE may hinder the ability of an observer to detect the presence of some significant gray-scale contrast. In this report, a psychophysical observer experiment was performed to determine if there is a significant difference in the ability of AHE and CLAHE to depict gray-scale contrast. Observers were presented with computed tomography (CT) images of the chest processed with AHE and CLAHE. Subtle artificial lesions were introduced into some images. The observers were asked to rate their confidence regarding the presence of the lesions; this rating-scale data was analyzed using receiver operating characteristic (ROC) curve techniques. These ROC curves were compared for significant differences in the observers' performances. In this report, no difference was found in the abilities of AHE and CLAHE to depict contrast information.
Gingival Biotype Assessment in a Healthy Periodontium: Transgingival Probing Method
Manjunath, R. G. Shiva; Sarkar, Arijit
2015-01-01
Background Gingival biotype is the thickness of the gingiva in the faciopalatal dimension. It has a significant impact on the outcome of the restorative, regenerative and implant therapy. It has been suggested that a direct co-relation exists with the susceptibility of gingival recession followed by any surgical procedure. So, the study was aimed to assess gingival biotype in different age groups of males and females using transgingival probing method. Materials and Methods Gingival thickness (GT) was evaluated in 336 patients including males and females of different age groups. The latter was based on the transparency of the periodontal probe through the gingival margin while probing the buccal sulcus. Final data collected was then used for statistical analysis. Results A significant difference was found between males and females with males showing thick biotype. Out of the total samples 76.9% of males showed thick biotype compared to 13.3 % of females which was statistically significant. Conclusion This was probably one of the few attempts to correlate gingival biotype with different age groups in males and females. A clear thick gingiva was found in more than two-third of the male subjects whereas majority of female subjects showed thin biotype. Also, it was seen that in females, the gingival biotype varies with age unlike in male. PMID:26155566
Statistical Methods for Identifying Sequence Motifs Affecting Point Mutations
Zhu, Yicheng; Neeman, Teresa; Yap, Von Bing; Huttley, Gavin A.
2017-01-01
Mutation processes differ between types of point mutation, genomic locations, cells, and biological species. For some point mutations, specific neighboring bases are known to be mechanistically influential. Beyond these cases, numerous questions remain unresolved, including: what are the sequence motifs that affect point mutations? How large are the motifs? Are they strand symmetric? And, do they vary between samples? We present new log-linear models that allow explicit examination of these questions, along with sequence logo style visualization to enable identifying specific motifs. We demonstrate the performance of these methods by analyzing mutation processes in human germline and malignant melanoma. We recapitulate the known CpG effect, and identify novel motifs, including a highly significant motif associated with A→G mutations. We show that major effects of neighbors on germline mutation lie within ±2 of the mutating base. Models are also presented for contrasting the entire mutation spectra (the distribution of the different point mutations). We show the spectra vary significantly between autosomes and X-chromosome, with a difference in T→C transition dominating. Analyses of malignant melanoma confirmed reported characteristic features of this cancer, including statistically significant strand asymmetry, and markedly different neighboring influences. The methods we present are made freely available as a Python library https://bitbucket.org/pycogent3/mutationmotif. PMID:27974498
Comparing the effects of reflexology and relaxation on fatigue in women with multiple sclerosis
Nazari, Fatemeh; Shahreza, Mozhgan Soheili; Shaygannejad, Vahid; Valiani, Mahboubeh
2015-01-01
Background: Fatigue is the most common and highly disabling symptom of multiple sclerosis (MS) that has negative effects on employment, the process of socialization, compliance with the disease, and other factors effective on activities of daily living. The usage of complementary and alternative medicine methods in MS patients is higher than in the general population. However, there is no scientific evidence to support their effectiveness. Therefore, this study aimed to compare the effects of reflexology and relaxation on fatigue in women with MS. Materials and Methods: This study is a single-blinded randomized clinical trial that was done on 75 patients with MS who referred to the MS Clinic of Ayatollah Kashani Hospital (Isfahan, Iran). After simple non-random sampling, participants were randomly assigned by minimization method to three groups: Reflexology, relaxation, and control groups (25 patients in each group). In the experimental groups, the interventions foot reflexology and relaxation (Jacobson and Benson) were performed for 4 weeks, twice a week for 40 min in each session, and the control group received care and routine medical treatment as directed by a physician. Data were collected through a questionnaire and the fatigue severity scale before, immediately after, and 2 months after interventions from all three groups. Data analysis was performed by SPSS version 18 using descriptive and inferential statistical methods. Results: Findings obtained from analysis of variance (ANOVA) showed that there was no significant difference in the mean fatigue severity scores in the pre-interventions between the three groups (P > 0.05), but there was significant difference immediately after and 2 months after interventions between the three groups (P < 0.05). Findings obtained from repeated measures (ANOVA) showed that there was significant difference in the mean fatigue severity scores during different times between the three groups (P < 0.05), while this difference was not significant in the control group (P > 0.05). Furthermore, least significant difference post-hoc test revealed that the mean scores of fatigue severity immediately after intervention was lower in the reflexology group than in the other two groups and were lower in the relaxation group than in the control group; 2 months after interventions, the mean scores of fatigue severity were lower in the reflexology group than in the other two groups, but there was no significant difference between the two groups of relaxation and control (P > 0.05). Conclusions: It seems that both interventions were effective in reducing fatigue, but the effects of reflexology on reducing fatigue were more than those of relaxation. Hence, as these two methods are effective and affordable techniques, they can be recommended. PMID:25878696
A generalised significance test for individual communities in networks.
Kojaku, Sadamori; Masuda, Naoki
2018-05-09
Many empirical networks have community structure, in which nodes are densely interconnected within each community (i.e., a group of nodes) and sparsely across different communities. Like other local and meso-scale structure of networks, communities are generally heterogeneous in various aspects such as the size, density of edges, connectivity to other communities and significance. In the present study, we propose a method to statistically test the significance of individual communities in a given network. Compared to the previous methods, the present algorithm is unique in that it accepts different community-detection algorithms and the corresponding quality function for single communities. The present method requires that a quality of each community can be quantified and that community detection is performed as optimisation of such a quality function summed over the communities. Various community detection algorithms including modularity maximisation and graph partitioning meet this criterion. Our method estimates a distribution of the quality function for randomised networks to calculate a likelihood of each community in the given network. We illustrate our algorithm by synthetic and empirical networks.
Han, Bing; Yu, Hao; Friedberg, Mark W
2017-04-01
To evaluate the effects of the parent-reported medical home status on health care utilization, expenditures, and quality for children. Medical Expenditure Panel Survey (MEPS) during 2004-2012, including a total of 9,153 children who were followed up for 2 years in the survey. We took a causal difference-in-differences approach using inverse probability weighting and doubly robust estimators to study how changes in medical home status over a 2-year period affected children's health care outcomes. Our analysis adjusted for children's sociodemographic, health, and insurance statuses. We conducted sensitivity analyses using alternative statistical methods, different approaches to outliers and missing data, and accounting for possible common-method biases. Compared with children whose parents reported having medical homes in both years 1 and 2, those who had medical homes in year 1 but lost them in year 2 had significantly lower parent-reported ratings of health care quality and higher utilization of emergency care. Compared with children whose parents reported having no medical homes in both years, those who did not have medical homes in year 1 but gained them in year 2 had significantly higher ratings of health care quality, but no significant differences in health care expenditures and utilization. Having a medical home may help improve health care quality for children; losing a medical home may lead to higher utilization of emergency care. © Health Research and Educational Trust.
Mateos-Pérez, José María; Soto-Montenegro, María Luisa; Peña-Zalbidea, Santiago; Desco, Manuel; Vaquero, Juan José
2016-02-01
We present a novel segmentation algorithm for dynamic PET studies that groups pixels according to the similarity of their time-activity curves. Sixteen mice bearing a human tumor cell line xenograft (CH-157MN) were imaged with three different (68)Ga-DOTA-peptides (DOTANOC, DOTATATE, DOTATOC) using a small animal PET-CT scanner. Regional activities (input function and tumor) were obtained after manual delineation of regions of interest over the image. The algorithm was implemented under the jClustering framework and used to extract the same regional activities as in the manual approach. The volume of distribution in the tumor was computed using the Logan linear method. A Kruskal-Wallis test was used to investigate significant differences between the manually and automatically obtained volumes of distribution. The algorithm successfully segmented all the studies. No significant differences were found for the same tracer across different segmentation methods. Manual delineation revealed significant differences between DOTANOC and the other two tracers (DOTANOC - DOTATATE, p=0.020; DOTANOC - DOTATOC, p=0.033). Similar differences were found using the leader-follower algorithm. An open implementation of a novel segmentation method for dynamic PET studies is presented and validated in rodent studies. It successfully replicated the manual results obtained in small-animal studies, thus making it a reliable substitute for this task and, potentially, for other dynamic segmentation procedures. Copyright © 2016 Elsevier Ltd. All rights reserved.
Comparison of three explicit multigrid methods for the Euler and Navier-Stokes equations
NASA Technical Reports Server (NTRS)
Chima, Rodrick V.; Turkel, Eli; Schaffer, Steve
1987-01-01
Three explicit multigrid methods, Ni's method, Jameson's finite-volume method, and a finite-difference method based on Brandt's work, are described and compared for two model problems. All three methods use an explicit multistage Runge-Kutta scheme on the fine grid, and this scheme is also described. Convergence histories for inviscid flow over a bump in a channel for the fine-grid scheme alone show that convergence rate is proportional to Courant number and that implicit residual smoothing can significantly accelerate the scheme. Ni's method was slightly slower than the implicitly-smoothed scheme alone. Brandt's and Jameson's methods are shown to be equivalent in form but differ in their node versus cell-centered implementations. They are about 8.5 times faster than Ni's method in terms of CPU time. Results for an oblique shock/boundary layer interaction problem verify the accuracy of the finite-difference code. All methods slowed considerably on the stretched viscous grid but Brandt's method was still 2.1 times faster than Ni's method.
Use of cervical vertebral dimensions for assessment of children growth.
Caldas, Maria de Paula; Ambrosano, Gláucia Maria Bovi; Haiter-Neto, Francisco
2007-04-01
The purpose of this study was to investigate whether skeletal maturation using cephalometric radiographs could be used in a Brazilian population. The study population was selected from the files of the Oral Radiological Clinic of the Dental School of Piracicaba, Brazil and consisted of 128 girls and 110 boys (7.0 to 15.9 years old) who had cephalometric and hand-wrist radiographs taken on the same day. Cervical vertebral bone age was evaluated using the method described by Mito and colleagues in 2002. Bone age was assessed by the Tanner-Whitehouse (TW3) method and was used as a gold standard to determine the reliability of cervical vertebral bone age. An analysis of variance and Tukey's post-hoc test were used to compare cervical vertebral bone age, bone age and chronological age at 5% significance level. The analysis of the Brazilian female children data showed that there was a statistically significant difference (p<0.05) between cervical vertebral bone age and chronological age and between bone age and chronological age. However no statistically significant difference (p>0.05) was found between cervical vertebral bone age and bone age. Differently, the analysis of the male children data revealed a statistically significant difference (p<0.05) between cervical vertebral bone age and bone age and between cervical vertebral bone age and chronological age (p<0.05). The findings of the present study suggest that the method for objectively evaluating skeletal maturation on cephalometric radiographs by determination of vertebral bone age can be applied to Brazilian females only. The development of a new method to objectively evaluate cervical vertebral bone age in males is needed.
Pope, Misty L.; Bussen, Michelle; Feige, Mary Ann; Shadix, Lois; Gonder, Sharon; Rodgers, Crystal; Chambers, Yildiz; Pulz, Jessica; Miller, Ken; Connell, Kevin; Standridge, Jon
2003-01-01
Escherichia coli is a routinely used microbiological indicator of water quality. To determine whether holding time and storage conditions had an effect on E. coli densities in surface water, studies were conducted in three phases, encompassing 24 sites across the United States and four commonly used monitoring methods. During all three phases of the study, E. coli samples were analyzed at time 0 and at 8, 24, 30, and 48 h after sample collection. During phase 1, when 4°C samples were evaluated by Colilert or by placing a membrane onto mFC medium followed by transfer to nutrient agar containing 4-methylumbelliferyl-β-d-glucuronide (mFC/NA-MUG), three of four sites showed no significant differences throughout the 48-h study. During phase 2, five of seven sites showed no significant difference between time 0 and 24 h by membrane filtration (mFC/NA-MUG). When evaluated by the Colilert method, five of seven sites showed no significant difference in E. coli density between time 0 and 48 h. During phase 3, 8 of 13 sites showed no significant differences in E. coli densities between time 0 and the 48-h holding time, regardless of method. Based on the results of these studies, it appears that if samples are held below 10°C and are not allowed to freeze, most surface water E. coli samples analyzed by commonly used methods beyond 8 h after sample collection can generate E. coli data comparable to those generated within 8 h of sample collection. Notwithstanding this conclusion, E. coli samples collected from surface waters should always be analyzed as soon as possible. PMID:14532081
Merk, Susanne; Wagner, Christina; Stock, Veronika; Eichberger, Marlis; Schmidlin, Patrick R; Roos, Malgorzata; Stawarczyk, Bogna
2016-11-08
This study investigates the retention load (RL) between ZrO₂ primary crowns and secondary polyetheretherketone (PEEK) crowns made by different fabrication methods with three different tapers. Standardized primary ZrO₂ crowns were fabricated with three different tapers: 0°, 1°, and 2° ( n = 10/group). Ten secondary crowns were fabricated (i) milled from breCam BioHPP blanks (PM); (ii) pressed from industrially fabricated PEEK pellets (PP) (BioHPP Pellet); or (iii) pressed from granular PEEK (PG) (BioHPP Granulat). One calibrated operator adjusted all crowns. In total, the RL of 90 secondary crowns were measured in pull-off tests at 50 mm/min, and each specimen was tested 20 times. Two- and one-way ANOVAs followed by a Scheffé's post-hoc test were used for data analysis ( p < 0.05). Within crowns with a 0° taper, the PP group showed significantly higher retention load values compared with the other groups. Among the 1° taper, the PM group presented significantly lower retention loads than the PP group. However, the pressing type had no impact on the results. Within the 2° taper, the fabrication method had no influence on the RL. Within the PM group, the 2° taper showed significantly higher retention load compared with the 1° taper. The taper with 0° was in the same range value as the 1° and 2° tapers. No impact of the taper on the retention value was observed between the PP groups. Within the PG groups, the 0° taper presented significantly lower RL than the 1° taper, whereas the 2° taper showed no differences. The fabrication method of the secondary PEEK crowns and taper angles showed no consistent effect within all tested groups.
Samak, M. Mosleh E. Abu; Bakar, A. Ashrif A.; Kashif, Muhammad; Zan, Mohd Saiful Dzulkifly
2016-01-01
This paper discusses numerical analysis methods for different geometrical features that have limited interval values for typically used sensor wavelengths. Compared with existing Finite Difference Time Domain (FDTD) methods, the alternating direction implicit (ADI)-FDTD method reduces the number of sub-steps by a factor of two to three, which represents a 33% time savings in each single run. The local one-dimensional (LOD)-FDTD method has similar numerical equation properties, which should be calculated as in the previous method. Generally, a small number of arithmetic processes, which result in a shorter simulation time, are desired. The alternating direction implicit technique can be considered a significant step forward for improving the efficiency of unconditionally stable FDTD schemes. This comparative study shows that the local one-dimensional method had minimum relative error ranges of less than 40% for analytical frequencies above 42.85 GHz, and the same accuracy was generated by both methods.
Comparing K-mer based methods for improved classification of 16S sequences.
Vinje, Hilde; Liland, Kristian Hovde; Almøy, Trygve; Snipen, Lars
2015-07-01
The need for precise and stable taxonomic classification is highly relevant in modern microbiology. Parallel to the explosion in the amount of sequence data accessible, there has also been a shift in focus for classification methods. Previously, alignment-based methods were the most applicable tools. Now, methods based on counting K-mers by sliding windows are the most interesting classification approach with respect to both speed and accuracy. Here, we present a systematic comparison on five different K-mer based classification methods for the 16S rRNA gene. The methods differ from each other both in data usage and modelling strategies. We have based our study on the commonly known and well-used naïve Bayes classifier from the RDP project, and four other methods were implemented and tested on two different data sets, on full-length sequences as well as fragments of typical read-length. The difference in classification error obtained by the methods seemed to be small, but they were stable and for both data sets tested. The Preprocessed nearest-neighbour (PLSNN) method performed best for full-length 16S rRNA sequences, significantly better than the naïve Bayes RDP method. On fragmented sequences the naïve Bayes Multinomial method performed best, significantly better than all other methods. For both data sets explored, and on both full-length and fragmented sequences, all the five methods reached an error-plateau. We conclude that no K-mer based method is universally best for classifying both full-length sequences and fragments (reads). All methods approach an error plateau indicating improved training data is needed to improve classification from here. Classification errors occur most frequent for genera with few sequences present. For improving the taxonomy and testing new classification methods, the need for a better and more universal and robust training data set is crucial.
Jithesh, C.; Venkataramana, V.; Penumatsa, Narendravarma; Reddy, S. N.; Poornima, K. Y.; Rajasigamani, K.
2015-01-01
Objectives: To determine and compare the potential difference of nickel release from three different orthodontic brackets, in different artificial pH, in different time intervals. Materials and Methods: Twenty-seven samples of three different orthodontic brackets were selected and grouped as 1, 2, and 3. Each group was divided into three subgroups depending on the type of orthodontic brackets, salivary pH and the time interval. The Nickel release from each subgroup were analyzed by using inductively coupled plasma-Atomic Emission Spectrophotometer (Perkin Elmer, Optima 2100 DV, USA) model. Quantitative analysis of nickel was performed three times, and the mean value was used as result. ANOVA (F-test) was used to test the significant difference among the groups at 0.05 level of significance (P < 0.05). The descriptive method of statistics was used to calculate the mean, standard deviation, minimum and maximum. SPSS 18 software ((SPSS.Ltd, Quarry bay, Hong Kong, PASW-statistics 18) was used to analyze the study. Result: The analysis shows a significant difference between three groups. The study shows that the nickel releases from the recycled stainless steel brackets have the highest at all 4.2 pH except in 120 h. Conclusion: The study result shows that the nickel release from the recycled stainless steel brackets is highest. Metal slot ceramic bracket release significantly less nickel. So, recycled stainless steel brackets should not be used for nickel allergic patients. Metal slot ceramic brackets are advisable. PMID:26538924
Sandage, Mary J; Rahn, Keith A; Smith, Audrey G
2017-02-01
The purpose of this study was to examine the influence of the heating, ventilation, and air-conditioning method on voice function following a voicing task using ecologically valid offices, one with radiant HVAC and one with forced air. A total of 12 consented participants (6 women, 6 men) narrated a video in each of 4 environmental conditions in a within-between repeated-measures design. Acoustic data were collected with an ambulatory phonation monitor and perceived phonatory effort was determined following the voicing task. Data were analyzed using a within-between repeated-measures analysis of variance with significance set at α < .05. Perceived phonatory effort did not differ between environments; however, a significant difference in vocal amplitude between 2 trials was identified for the male participants and physiologically significant differences in vocal amplitude were identified for male and female participants. The findings suggest that perceived phonatory effort may not be a sensitive measure of vocal function differences following a voicing task in ecologically valid office spaces despite significant acoustic findings. Future research should address longer exposure to environmental differences combined with a longer voicing task within ecologically valid work spaces as well as the recruitment of participants who have particular vulnerability to environmental perturbations.
Lee, Tzu-Cheng; Alessio, Adam M.; Wollenweber, Scott D.; Stearns, Charles W.; Bowen, Stephen R.; Kinahan, Paul E.
2015-01-01
Purpose: Respiratory-correlated positron emission tomography (PET/CT) 4D PET/CT is used to mitigate errors from respiratory motion; however, the optimal CT attenuation correction (CTAC) method for 4D PET/CT is unknown. The authors performed a phantom study to evaluate the quantitative performance of CTAC methods for 4D PET/CT in the ground truth setting. Methods: A programmable respiratory motion phantom with a custom movable insert designed to emulate a lung lesion and lung tissue was used for this study. The insert was driven by one of five waveforms: two sinusoidal waveforms or three patient-specific respiratory waveforms. 3DPET and 4DPET images of the phantom under motion were acquired and reconstructed with six CTAC methods: helical breath-hold (3DHEL), helical free-breathing (3DMOT), 4D phase-averaged (4DAVG), 4D maximum intensity projection (4DMIP), 4D phase-matched (4DMATCH), and 4D end-exhale (4DEXH) CTAC. Recovery of SUVmax, SUVmean, SUVpeak, and segmented tumor volume was evaluated as RCmax, RCmean, RCpeak, and RCvol, representing percent difference relative to the static ground truth case. Paired Wilcoxon tests and Kruskal–Wallis ANOVA were used to test for significant differences. Results: For 4DPET imaging, the maximum intensity projection CTAC produced significantly more accurate recovery coefficients than all other CTAC methods (p < 0.0001 over all metrics). Over all motion waveforms, ratios of 4DMIP CTAC recovery were 0.2 ± 5.4, −1.8 ± 6.5, −3.2 ± 5.0, and 3.0 ± 5.9 for RCmax, RCpeak, RCmean, and RCvol. In comparison, recovery coefficients for phase-matched CTAC were −8.4 ± 5.3, −10.5 ± 6.2, −7.6 ± 5.0, and −13.0 ± 7.7 for RCmax, RCpeak, RCmean, and RCvol. When testing differences between phases over all CTAC methods and waveforms, end-exhale phases were significantly more accurate (p = 0.005). However, these differences were driven by the patient-specific respiratory waveforms; when testing patient and sinusoidal waveforms separately, patient waveforms were significantly different between phases (p < 0.0001) while the sinusoidal waveforms were not significantly different (p = 0.98). When considering only the subset of 4DMATCH images that corresponded to the end-exhale image phase, 4DEXH, mean and interquartile range were similar to 4DMATCH but variability was considerably reduced. Conclusions: Comparative advantages in accuracy and precision of SUV metrics and segmented volumes were demonstrated with the use of the maximum intensity projection and end-exhale CT attenuation correction. While respiratory phase-matched CTAC should in theory provide optimal corrections, image artifacts and differences in implementation of 4DCT and 4DPET sorting can degrade the benefit of this approach. These results may be useful to guide the implementation, analysis, and development of respiratory-correlated thoracic PET/CT in the radiation oncology and diagnostic settings. PMID:25563252
Park, Jong-Kyoung; Lee, Wan-Sun; Kim, Hae-Young; Kim, Woong-Chul; Kim, Ji-Hwan
2015-04-01
To assess the marginal and internal gaps of the copings fabricated by computer-aided milling and direct metal laser sintering (DMLS) systems in comparison to casting method. Ten metal copings were fabricated by casting, computer-aided milling, and DMLS. Seven mesiodistal and labiolingual positions were then measured, and each of these were divided into the categories; marginal gap (MG), cervical gap (CG), axial wall at internal gap (AG), and incisal edge at internal gap (IG). Evaluation was performed by a silicone replica technique. A digital microscope was used for measurement of silicone layer. Statistical analyses included one-way and repeated measure ANOVA to test the difference between the fabrication methods and categories of measured points (α=.05), respectively. The mean gap differed significantly with fabrication methods (P<.001). Casting produced the narrowest gap in each of the four measured positions, whereas CG, AG, and IG proved narrower in computer-aided milling than in DMLS. Thus, with the exception of MG, all positions exhibited a significant difference between computer-aided milling and DMLS (P<.05). Although the gap was found to vary with fabrication methods, the marginal and internal gaps of the copings fabricated by computer-aided milling and DMLS fell within the range of clinical acceptance (<120 µm). However, the statistically significant difference to conventional casting indicates that the gaps in computer-aided milling and DMLS fabricated restorations still need to be further reduced.
Nissim, Nir; Shahar, Yuval; Boland, Mary Regina; Tatonetti, Nicholas P; Elovici, Yuval; Hripcsak, George; Moskovitch, Robert
2018-01-01
Background and Objectives Labeling instances by domain experts for classification is often time consuming and expensive. To reduce such labeling efforts, we had proposed the application of active learning (AL) methods, introduced our CAESAR-ALE framework for classifying the severity of clinical conditions, and shown its significant reduction of labeling efforts. The use of any of three AL methods (one well known [SVM-Margin], and two that we introduced [Exploitation and Combination_XA]) significantly reduced (by 48% to 64%) condition labeling efforts, compared to standard passive (random instance-selection) SVM learning. Furthermore, our new AL methods achieved maximal accuracy using 12% fewer labeled cases than the SVM-Margin AL method. However, because labelers have varying levels of expertise, a major issue associated with learning methods, and AL methods in particular, is how to best to use the labeling provided by a committee of labelers. First, we wanted to know, based on the labelers’ learning curves, whether using AL methods (versus standard passive learning methods) has an effect on the Intra-labeler variability (within the learning curve of each labeler) and inter-labeler variability (among the learning curves of different labelers). Then, we wanted to examine the effect of learning (either passively or actively) from the labels created by the majority consensus of a group of labelers. Methods We used our CAESAR-ALE framework for classifying the severity of clinical conditions, the three AL methods and the passive learning method, as mentioned above, to induce the classifications models. We used a dataset of 516 clinical conditions and their severity labeling, represented by features aggregated from the medical records of 1.9 million patients treated at Columbia University Medical Center. We analyzed the variance of the classification performance within (intra-labeler), and especially among (inter-labeler) the classification models that were induced by using the labels provided by seven labelers. We also compared the performance of the passive and active learning models when using the consensus label. Results The AL methods produced, for the models induced from each labeler, smoother Intra-labeler learning curves during the training phase, compared to the models produced when using the passive learning method. The mean standard deviation of the learning curves of the three AL methods over all labelers (mean: 0.0379; range: [0.0182 to 0.0496]), was significantly lower (p = 0.049) than the Intra-labeler standard deviation when using the passive learning method (mean: 0.0484; range: [0.0275 to 0.0724). Using the AL methods resulted in a lower mean Inter-labeler AUC standard deviation among the AUC values of the labelers’ different models during the training phase, compared to the variance of the induced models’ AUC values when using passive learning. The Inter-labeler AUC standard deviation, using the passive learning method (0.039), was almost twice as high as the Inter-labeler standard deviation using our two new AL methods (0.02 and 0.019, respectively). The SVM-Margin AL method resulted in an Inter-labeler standard deviation (0.029) that was higher by almost 50% than that of our two AL methods. The difference in the inter-labeler standard deviation between the passive learning method and the SVM-Margin learning method was significant (p = 0.042). The difference between the SVM-Margin and Exploitation method was insignificant (p = 0.29), as was the difference between the Combination_XA and Exploitation methods (p = 0.67). Finally, using the consensus label led to a learning curve that had a higher mean intra-labeler variance, but resulted eventually in an AUC that was at least as high as the AUC achieved using the gold standard label and that was always higher than the expected mean AUC of a randomly selected labeler, regardless of the choice of learning method (including a passive learning method). Using a paired t-test, the difference between the intra-labeler AUC standard deviation when using the consensus label, versus that value when using the other two labeling strategies, was significant only when using the passive learning method (p = 0.014), but not when using any of the three AL methods. Conclusions The use of AL methods, (a) reduces intra-labeler variability in the performance of the induced models during the training phase, and thus reduces the risk of halting the process at a local minimum that is significantly different in performance from the rest of the learned models; and (b) reduces Inter-labeler performance variance, and thus reduces the dependence on the use of a particular labeler. In addition, the use of a consensus label, agreed upon by a rather uneven group of labelers, might be at least as good as using the gold standard labeler, who might not be available, and certainly better than randomly selecting one of the group’s individual labelers. Finally, using the AL methods when provided by the consensus label reduced the intra-labeler AUC variance during the learning phase, compared to using passive learning. PMID:28456512
Using Elderly Educators to Increase Colorectal Cancer Screening.
ERIC Educational Resources Information Center
Weinrich, Sally P.; And Others
1993-01-01
Used elderly educator method for increasing rate of return of fecal occult blood sampling in colorectal screening among 171 socioeconomically disadvantaged older persons. Two methods using elderly educators had overall response rate of more than 60%. Found statistically significant difference between two methods that used elderly educators and two…
40 CFR 53.59 - Aerosol transport test for Class I equivalent method samplers.
Code of Federal Regulations, 2011 CFR
2011-07-01
... sample collection filter) differs significantly from that specified for reference method samplers as... transport is the percentage of a laboratory challenge aerosol which penetrates to the active sample filter of the candidate equivalent method sampler. (2) The active sample filter is the exclusive filter...
40 CFR 53.59 - Aerosol transport test for Class I equivalent method samplers.
Code of Federal Regulations, 2010 CFR
2010-07-01
... sample collection filter) differs significantly from that specified for reference method samplers as... transport is the percentage of a laboratory challenge aerosol which penetrates to the active sample filter of the candidate equivalent method sampler. (2) The active sample filter is the exclusive filter...
40 CFR 53.59 - Aerosol transport test for Class I equivalent method samplers.
Code of Federal Regulations, 2013 CFR
2013-07-01
... sample collection filter) differs significantly from that specified for reference method samplers as... transport is the percentage of a laboratory challenge aerosol which penetrates to the active sample filter of the candidate equivalent method sampler. (2) The active sample filter is the exclusive filter...
40 CFR 53.59 - Aerosol transport test for Class I equivalent method samplers.
Code of Federal Regulations, 2014 CFR
2014-07-01
... sample collection filter) differs significantly from that specified for reference method samplers as... transport is the percentage of a laboratory challenge aerosol which penetrates to the active sample filter of the candidate equivalent method sampler. (2) The active sample filter is the exclusive filter...
40 CFR 53.59 - Aerosol transport test for Class I equivalent method samplers.
Code of Federal Regulations, 2012 CFR
2012-07-01
... sample collection filter) differs significantly from that specified for reference method samplers as... transport is the percentage of a laboratory challenge aerosol which penetrates to the active sample filter of the candidate equivalent method sampler. (2) The active sample filter is the exclusive filter...
Perception of fore-and-aft whole-body vibration intensity measured by two methods.
Forta, Nazım Gizem; Schust, Marianne
2015-01-01
This experimental study investigated the perception of fore-and-aft whole-body vibration intensity using cross-modality matching (CM) and magnitude estimation (ME) methods. Thirteen subjects were seated on a rigid seat without a backrest and exposed to sinusoidal stimuli from 0.8 to 12.5 Hz and 0.4 to 1.6 ms(-2) r.m.s. The Stevens exponents did not significantly depend on vibration frequency or the measurement method. The ME frequency weightings depended significantly on vibration frequency, but the CM weightings did not. Using the CM and ME weightings would result in higher weighted exposures than those calculated using the ISO (2631-1, 1997) Wd. Compared with ISO Wk, the CM and ME-weighted exposures would be greater at 1.6 Hz and lesser above that frequency. The CM and ME frequency weightings based on the median ratings for the reference vibration condition did not differ significantly. The lack of a method effect for weightings and for Stevens exponents suggests that the findings from the two methods are comparable. Frequency weighting curves for seated subjects for x-axis whole-body vibration were derived from an experiment using two different measurement methods and were compared with the Wd and Wk weighting curves in ISO 2631-1 (1997).
Spindler, Patrice; Paretti, Nick V.
2007-01-01
The Arizona Department of Environmental Quality (ADEQ) and the U.S. Environmental Protection Agency (USEPA) Ecological Monitoring and Assessment Program (EMAP), use different field methods for collecting macroinvertebrate samples and habitat data for bioassessment purposes. Arizona’s Biocriteria index was developed using a riffle habitat sampling methodology, whereas the EMAP method employs a multi-habitat sampling protocol. There was a need to demonstrate comparability of these different bioassessment methodologies to allow use of the EMAP multi-habitat protocol for both statewide probabilistic assessments for integration of the EMAP data into the national (305b) assessment and for targeted in-state bioassessments for 303d determinations of standards violations and impaired aquatic life conditions. The purpose of this study was to evaluate whether the two methods yield similar bioassessment results, such that the data could be used interchangeably in water quality assessments. In this Regional EMAP grant funded project, a probabilistic survey of 30 sites in the Little Colorado River basin was conducted in the spring of 2007. Macroinvertebrate and habitat data were collected using both ADEQ and EMAP sampling methods, from adjacent reaches within these stream channels.
All analyses indicated that the two macroinvertebrate sampling methods were significantly correlated. ADEQ and EMAP samples were classified into the same scoring categories (meeting, inconclusive, violating the biocriteria standard) 82% of the time. When the ADEQ-IBI was applied to both the ADEQ and EMAP taxa lists, the resulting IBI scores were significantly correlated (r=0.91), even though only 4 of the 7 metrics in the IBI were significantly correlated. The IBI scores from both methods were significantly correlated to the percent of riffle habitat, even though the average percent riffle habitat was only 30% of the stream reach. Multivariate analyses found that the percent riffle was an important attribute for both datasets in classifying IBI scores into assessment categories.
Habitat measurements generated from EMAP and ADEQ methods were also significantly correlated; 13 of 16 habitat measures were significantly correlated (p<0.01). The visual-based percentage estimates of percent riffle and pool habitats, vegetative cover and percent canopy cover, and substrate measurements of percent fine substrate and embeddedness were all remarkably similar, given the different field methods used. A multivariate analysis identified substrate and flow conditions, as well as canopy cover as important combinations of habitat attributes affecting both IBI scores. These results indicate that similar habitat measures can be obtained using two different field sampling protocols. In addition, similar combinations of these habitat parameters were important to macroinvertebrate community condition in multivariate analyses of both ADEQ and EMAP datasets.
These results indicate the two sampling methods for macroinvertebrates and habitat data were very similar in terms of bioassessment results and stressors. While the bioassessment category was not identical for all sites, overall the assessments were significantly correlated, providing similar bioassessment results for the cold water streams used in this study. The findings of this study indicate that ADEQ can utilize either a riffle-based sampling methodology or a multi-habitat sampling approach in cold water streams as both yield similar results relative to the macroinvertebrate assemblage. These results will allow for use of either macroinvertebrate dataset to determine water quality standards compliance with the ADEQ Indexes of Biological Integrity, for which threshold values were just recently placed into the Arizona Surface Water Quality Standards. While this survey did not include warm water desert streams of Arizona, we would predict that EMAP and ADEQ sampling methodologies would provide similar bioassessment results and would not be significantly different, as we have found that the percent riffle habitat in cold and warm water perennial, wadeable streams is not significantly different. However, a comparison study of sampling methodologies in warm water streams should be conducted to confirm the predicted similarity of bioassessment results. ADEQ will continue to implement a monitoring strategy that includes probabilistic monitoring for a statewide ecological assessment of stream conditions. Conclusions from this study will guide decisions regarding the most appropriate sampling methods for future probabilistic monitoring sample plans.
The Relative Effectiveness of Expository Methods of Teaching Science
ERIC Educational Resources Information Center
Babikian, Elijah
1973-01-01
Two methods of instruction (question-answer and question-incomplete-answer) are utilized in teaching a unit on thermal energy. Effectiveness, as measured by a posttest, confirmed significant differences in the two modes of instruction. (DF)
Roth, Johannes; Müller, Nicolle; Lehmann, Thomas; Böer, Klas; Löbel, Sven; Pum, Joachim; Müller, Ulrich Alfons
2018-01-01
HbA 1c is the most important surrogate parameter to assess the quality of diabetes care and is also used for the diagnosis of diabetes mellitus (DM) since 2010. We investigated the comparability of 3 HbA 1c methods in the city of Jena (Germany). The HbA 1c determination was carried out in 50 healthy subjects and 24 people with DM (age 51.2±16.3 years, HbA 1c 6.8±2.2%) with 3 different hemoglobin A 1c testing methods at 4 locations in one city. Our laboratory (HPLC method) served as a reference for comparing the results. All methods are IFCC standardized and all devices are certified by the interlaboratory test. The mean HbA 1c of people without diabetes was: laboratory A (TOSOH G8, HPLC) 5.7±0.3%; laboratory B (TOSOH G8, HPLC) 5.5±0.3%, laboratory C (VARIANT II) 5.2±0.3%; laboratory D (COBAS INT.) 5.6±0.3%. All differences are significant (p=0.001).The mean HbA 1c of patients with mild to moderate elevated HbA 1c was: Laboratory A 7.5±0.9%; B 7.3±1.0%; C 7.0±0.9%; D 7.5±1.1%. Differences are significant (p=0.001) except between laboratory A and D (p=0.8).The mean HbA 1c of patients with massively increased HbA 1c was: laboratory A 11.5±1.8%; laboratory B 11.4±1.8%; laboratory C 10.8±1.6%; laboratory D 11.5±1.5%. Differences between laboratory A and C, as well as between C and D were significant (p=0.001). The mean IFCC standardized HbA 1c from 75 people differs by up to 0.5% absolute between 4 laboratories. This difference is clinically significant and may lead to misdiagnosis and wrong treatment decisions, while HbA 1c value from one patient were analyzed in different laboratories within a short time. © Georg Thieme Verlag KG Stuttgart · New York.
Portillo, M C; Gonzalez, J M
2008-08-01
Molecular fingerprints of microbial communities are a common method for the analysis and comparison of environmental samples. The significance of differences between microbial community fingerprints was analyzed considering the presence of different phylotypes and their relative abundance. A method is proposed by simulating coverage of the analyzed communities as a function of sampling size applying a Cramér-von Mises statistic. Comparisons were performed by a Monte Carlo testing procedure. As an example, this procedure was used to compare several sediment samples from freshwater ponds using a relative quantitative PCR-DGGE profiling technique. The method was able to discriminate among different samples based on their molecular fingerprints, and confirmed the lack of differences between aliquots from a single sample.
Comparison of fecal egg counting methods in four livestock species.
Paras, Kelsey L; George, Melissa M; Vidyashankar, Anand N; Kaplan, Ray M
2018-06-15
Gastrointestinal nematode parasites are important pathogens of all domesticated livestock species. Fecal egg counts (FEC) are routinely used for evaluating anthelmintic efficacy and for making targeted anthelmintic treatment decisions. Numerous FEC techniques exist and vary in precision and accuracy. These performance characteristics are especially important when performing fecal egg count reduction tests (FECRT). The objective of this study was to compare the accuracy and precision of three commonly used FEC methods and determine if differences existed among livestock species. In this study, we evaluated the modified-Wisconsin, 3-chamber (high-sensitivity) McMaster, and Mini-FLOTAC methods in cattle, sheep, horses, and llamas in three phases. In the first phase, we performed an egg-spiking study to assess the egg recovery rate and accuracy of the different FEC methods. In the second phase, we examined clinical samples from four different livestock species and completed multiple replicate FEC using each method. In the last phase, we assessed the cheesecloth straining step as a potential source of egg loss. In the egg-spiking study, the Mini-FLOTAC recovered 70.9% of the eggs, which was significantly higher than either the McMaster (P = 0.002) or Wisconsin (P = 0.002). In the clinical samples from ruminants, Mini-FLOTAC consistently yielded the highest EPG, revealing a significantly higher level of egg recovery (P < 0.0001). For horses and llamas, both McMaster and Mini-FLOTAC yielded significantly higher EPG than Wisconsin (P < 0.0001, P < 0.0001, P < 0.001, and P = 0.024). Mini-FLOTAC was the most accurate method and was the most precise test for both species of ruminants. The Wisconsin method was the most precise for horses and McMaster was more precise for llama samples. We compared the Wisconsin and Mini-FLOTAC methods using a modified technique where both methods were performed using either the Mini-FLOTAC sieve or cheesecloth. The differences in the estimated mean EPG on log scale between the Wisconsin and mini-FLOTAC methods when cheesecloth was used (P < 0.0001) and when cheesecloth was excluded (P < 0.0001) were significant, providing strong evidence that the straining step is an important source of error. The high accuracy and precision demonstrated in this study for the Mini-FLOTAC, suggest that this method can be recommended for routine use in all host species. The benefits of Mini-FLOTAC will be especially relevant when high accuracy is important, such as when performing FECRT. Copyright © 2018 Elsevier B.V. All rights reserved.
Optical flow estimation on image sequences with differently exposed frames
NASA Astrophysics Data System (ADS)
Bengtsson, Tomas; McKelvey, Tomas; Lindström, Konstantin
2015-09-01
Optical flow (OF) methods are used to estimate dense motion information between consecutive frames in image sequences. In addition to the specific OF estimation method itself, the quality of the input image sequence is of crucial importance to the quality of the resulting flow estimates. For instance, lack of texture in image frames caused by saturation of the camera sensor during exposure can significantly deteriorate the performance. An approach to avoid this negative effect is to use different camera settings when capturing the individual frames. We provide a framework for OF estimation on such sequences that contain differently exposed frames. Information from multiple frames are combined into a total cost functional such that the lack of an active data term for saturated image areas is avoided. Experimental results demonstrate that using alternate camera settings to capture the full dynamic range of an underlying scene can clearly improve the quality of flow estimates. When saturation of image data is significant, the proposed methods show superior performance in terms of lower endpoint errors of the flow vectors compared to a set of baseline methods. Furthermore, we provide some qualitative examples of how and when our method should be used.
Detection of LSB+/-1 steganography based on co-occurrence matrix and bit plane clipping
NASA Astrophysics Data System (ADS)
Abolghasemi, Mojtaba; Aghaeinia, Hassan; Faez, Karim; Mehrabi, Mohammad Ali
2010-01-01
Spatial LSB+/-1 steganography changes smooth characteristics between adjoining pixels of the raw image. We present a novel steganalysis method for LSB+/-1 steganography based on feature vectors derived from the co-occurrence matrix in the spatial domain. We investigate how LSB+/-1 steganography affects the bit planes of an image and show that it changes more least significant bit (LSB) planes of it. The co-occurrence matrix is derived from an image in which some of its most significant bit planes are clipped. By this preprocessing, in addition to reducing the dimensions of the feature vector, the effects of embedding were also preserved. We compute the co-occurrence matrix in different directions and with different dependency and use the elements of the resulting co-occurrence matrix as features. This method is sensitive to the data embedding process. We use a Fisher linear discrimination (FLD) classifier and test our algorithm on different databases and embedding rates. We compare our scheme with the current LSB+/-1 steganalysis methods. It is shown that the proposed scheme outperforms the state-of-the-art methods in detecting the LSB+/-1 steganographic method for grayscale images.
Nissim, Nir; Shahar, Yuval; Elovici, Yuval; Hripcsak, George; Moskovitch, Robert
2017-09-01
Labeling instances by domain experts for classification is often time consuming and expensive. To reduce such labeling efforts, we had proposed the application of active learning (AL) methods, introduced our CAESAR-ALE framework for classifying the severity of clinical conditions, and shown its significant reduction of labeling efforts. The use of any of three AL methods (one well known [SVM-Margin], and two that we introduced [Exploitation and Combination_XA]) significantly reduced (by 48% to 64%) condition labeling efforts, compared to standard passive (random instance-selection) SVM learning. Furthermore, our new AL methods achieved maximal accuracy using 12% fewer labeled cases than the SVM-Margin AL method. However, because labelers have varying levels of expertise, a major issue associated with learning methods, and AL methods in particular, is how to best to use the labeling provided by a committee of labelers. First, we wanted to know, based on the labelers' learning curves, whether using AL methods (versus standard passive learning methods) has an effect on the Intra-labeler variability (within the learning curve of each labeler) and inter-labeler variability (among the learning curves of different labelers). Then, we wanted to examine the effect of learning (either passively or actively) from the labels created by the majority consensus of a group of labelers. We used our CAESAR-ALE framework for classifying the severity of clinical conditions, the three AL methods and the passive learning method, as mentioned above, to induce the classifications models. We used a dataset of 516 clinical conditions and their severity labeling, represented by features aggregated from the medical records of 1.9 million patients treated at Columbia University Medical Center. We analyzed the variance of the classification performance within (intra-labeler), and especially among (inter-labeler) the classification models that were induced by using the labels provided by seven labelers. We also compared the performance of the passive and active learning models when using the consensus label. The AL methods: produced, for the models induced from each labeler, smoother Intra-labeler learning curves during the training phase, compared to the models produced when using the passive learning method. The mean standard deviation of the learning curves of the three AL methods over all labelers (mean: 0.0379; range: [0.0182 to 0.0496]), was significantly lower (p=0.049) than the Intra-labeler standard deviation when using the passive learning method (mean: 0.0484; range: [0.0275-0.0724). Using the AL methods resulted in a lower mean Inter-labeler AUC standard deviation among the AUC values of the labelers' different models during the training phase, compared to the variance of the induced models' AUC values when using passive learning. The Inter-labeler AUC standard deviation, using the passive learning method (0.039), was almost twice as high as the Inter-labeler standard deviation using our two new AL methods (0.02 and 0.019, respectively). The SVM-Margin AL method resulted in an Inter-labeler standard deviation (0.029) that was higher by almost 50% than that of our two AL methods The difference in the inter-labeler standard deviation between the passive learning method and the SVM-Margin learning method was significant (p=0.042). The difference between the SVM-Margin and Exploitation method was insignificant (p=0.29), as was the difference between the Combination_XA and Exploitation methods (p=0.67). Finally, using the consensus label led to a learning curve that had a higher mean intra-labeler variance, but resulted eventually in an AUC that was at least as high as the AUC achieved using the gold standard label and that was always higher than the expected mean AUC of a randomly selected labeler, regardless of the choice of learning method (including a passive learning method). Using a paired t-test, the difference between the intra-labeler AUC standard deviation when using the consensus label, versus that value when using the other two labeling strategies, was significant only when using the passive learning method (p=0.014), but not when using any of the three AL methods. The use of AL methods, (a) reduces intra-labeler variability in the performance of the induced models during the training phase, and thus reduces the risk of halting the process at a local minimum that is significantly different in performance from the rest of the learned models; and (b) reduces Inter-labeler performance variance, and thus reduces the dependence on the use of a particular labeler. In addition, the use of a consensus label, agreed upon by a rather uneven group of labelers, might be at least as good as using the gold standard labeler, who might not be available, and certainly better than randomly selecting one of the group's individual labelers. Finally, using the AL methods: when provided by the consensus label reduced the intra-labeler AUC variance during the learning phase, compared to using passive learning. Copyright © 2017 Elsevier B.V. All rights reserved.
Pasion, Editha; Good, Levell; Tizon, Jisebelle; Krieger, Staci; O'Kier, Catherine; Taylor, Nicole; Johnson, Jennifer; Horton, Carrie M; Peterson, Mary
2010-11-01
To determine if the monitor cursor-line feature on bedside monitors is accurate for measuring central venous and pulmonary artery pressures in cardiac surgery patients. Central venous and pulmonary artery pressures were measured via 3 methods (end-expiratory graphic recording, monitor cursor-line display, and monitor digital display) in a convenience sample of postoperative cardiac surgery patients. Pressures were measured twice during both mechanical ventilation and spontaneous breathing. Analysis of variance was used to determine differences between measurement methods and the percentage of monitor pressures that differed by 4 mm Hg or more from the measurement obtained from the graphic recording. Significance level was set at P less than .05. Twenty-five patients were studied during mechanical ventilation (50 measurements) and 21 patients during spontaneous breathing (42 measurements). Measurements obtained via the 3 methods did not differ significantly for either type of pressure (P > .05). Graphically recorded pressures and measurements obtained via the monitor cursor-line or digital display methods differed by 4 mm Hg or more in 4% and 6% of measurements, respectively, during mechanical ventilation and 4% and 11%, respectively, during spontaneous breathing. The monitor cursor-line method for measuring central venous and pulmonary artery pressures may be a reasonable alternative to the end-expiratory graphic recording method in hemodynamically stable, postoperative cardiac surgery patients. Use of the digital display on the bedside monitor may result in larger discrepancies from the graphically recorded pressures than when the cursor-line method is used, particularly in spontaneously breathing patients.
Gu, Hai Ting; Xie, Ping; Sang, Yan Fang; Wu, Zi Yi
2018-04-01
Abrupt change is an important manifestation of hydrological process with dramatic variation in the context of global climate change, the accurate recognition of which has great significance to understand hydrological process changes and carry out the actual hydrological and water resources works. The traditional method is not reliable at both ends of the samples. The results of the methods are often inconsistent. In order to solve the problem, we proposed a comprehensive weighted recognition method for hydrological abrupt change based on weighting by comparing of 12 commonly used methods for testing change points. The reliability of the method was verified by Monte Carlo statistical test. The results showed that the efficiency of the 12 methods was influenced by the factors including coefficient of variation (Cv), deviation coefficient (Cs) before the change point, mean value difference coefficient, Cv difference coefficient and Cs difference coefficient, but with no significant relationship with the mean value of the sequence. Based on the performance of each method, the weight of each test method was given following the results from statistical test. The sliding rank sum test method and the sliding run test method had the highest weight, whereas the RS test method had the lowest weight. By this means, the change points with the largest comprehensive weight could be selected as the final result when the results of the different methods were inconsistent. This method was used to analyze the daily maximum sequence of Jiajiu station in the lower reaches of the Lancang River (1-day, 3-day, 5-day, 7-day and 1-month). The results showed that each sequence had obvious jump variation in 2004, which was in agreement with the physical causes of hydrological process change and water conservancy construction. The rationality and reliability of the proposed method was verified.
Rodríguez, Francisco I; Procura, Francisco; Bueno, Dante J
2018-06-26
The present work compared 7 different culture methods and 3 selective-differential plating media for Salmonella ser. Enteritidis (SE) and S. ser. Typhimurium (ST) isolation using artificially contaminated poultry feces. The sensitivity (Se) and accuracy (AC) values increased when Modified Semisolid Rappaport Vassiliadis (MSRV) methods were used in place of the Tetrathionate (TT) or Tetrathionate Hajna broth (TTH) method in the enrichment step. However, there was no significant difference between the pre-enrichment incubation at 4 to 6 and 18 to 24 h for MSRV5 and MSRV24 methods, respectively. All Salmonella strains were recovered in the lowest dilutions tested for MSRV24 and 3 out of 4 for MSRV5 methods (2 to 10 cfu/25 g). The TT and TTH methods showed a detection limit between 2.2 × 101 and 1.0 × 106 cfu/25 g of fecal sample. The agreement was variable between the methods. However, there was a very good agreement between the MSRV5 and MSRV24 methods, and between tetrathionate direct (TTD, no pre-enrichment media used) and buffered peptone water 18 to 24 h Tetrathionate broth combination (TT24 method) for Salmonella strains. The 3 selective-differential plating media showed an agreement between fair and excellent. They performed a high Se and AC in the MSRV methods for Salmonella strains. There was a significant difference between center and periphery for MSRV methods, and there was a fair agreement between them for all strains. The MSRV methods are better than TT/TTH methods for the isolation of different strains of SE and ST in poultry fecal samples. The MSRV5 method can be used to reduce the time for the detection of SE and ST in these samples. Furthermore, a loopful of the periphery of the growth should be streaked onto differential-selective plating media, even in the absence of halo, to decrease the number of false negative results.
Boiano, J M; Wallace, M E; Sieber, W K; Groff, J H; Wang, J; Ashley, K
2000-08-01
A field study was conducted with the goal of comparing the performance of three recently developed or modified sampling and analytical methods for the determination of airborne hexavalent chromium (Cr(VI)). The study was carried out in a hard chrome electroplating facility and in a jet engine manufacturing facility where airborne Cr(VI) was expected to be present. The analytical methods evaluated included two laboratory-based procedures (OSHA Method ID-215 and NIOSH Method 7605) and a field-portable method (NIOSH Method 7703). These three methods employ an identical sampling methodology: collection of Cr(VI)-containing aerosol on a polyvinyl chloride (PVC) filter housed in a sampling cassette, which is connected to a personal sampling pump calibrated at an appropriate flow rate. The basis of the analytical methods for all three methods involves extraction of the PVC filter in alkaline buffer solution, chemical isolation of the Cr(VI) ion, complexation of the Cr(VI) ion with 1,5-diphenylcarbazide, and spectrometric measurement of the violet chromium diphenylcarbazone complex at 540 nm. However, there are notable specific differences within the sample preparation procedures used in three methods. To assess the comparability of the three measurement protocols, a total of 20 side-by-side air samples were collected, equally divided between a chromic acid electroplating operation and a spray paint operation where water soluble forms of Cr(VI) were used. A range of Cr(VI) concentrations from 0.6 to 960 microg m(-3), with Cr(VI) mass loadings ranging from 0.4 to 32 microg, was measured at the two operations. The equivalence of the means of the log-transformed Cr(VI) concentrations obtained from the different analytical methods was compared. Based on analysis of variance (ANOVA) results, no statistically significant differences were observed between mean values measured using each of the three methods. Small but statistically significant differences were observed between results obtained from performance evaluation samples for the NIOSH field method and the OSHA laboratory method.
Ichikawa, Tamaki; Kitanosono, Takashi; Koizumi, Jun; Ogushi, Yoichi; Tanaka, Osamu; Endo, Jun; Hashimoto, Takeshi; Kawada, Shuichi; Saito, Midori; Kobayashi, Makiko; Imai, Yutaka
2007-12-20
We evaluated the usefulness of radiological reporting that combines continuous speech recognition (CSR) and error correction by transcriptionists. Four transcriptionists (two with more than 10 years' and two with less than 3 months' transcription experience) listened to the same 100 dictation files and created radiological reports using conventional transcription and a method that combined CSR with manual error correction by the transcriptionists. We compared the 2 groups using the 2 methods for accuracy and report creation time and evaluated the transcriptionists' inter-personal dependence on accuracy rate and report creation time. We used a CSR system that did not require the training of the system to recognize the user's voice. We observed no significant difference in accuracy between the 2 groups and 2 methods that we tested, though transcriptionists with greater experience transcribed faster than those with less experience using conventional transcription. Using the combined method, error correction speed was not significantly different between two groups of transcriptionists with different levels of experience. Combining CSR and manual error correction by transcriptionists enabled convenient and accurate radiological reporting.
Alkahtani, Shaea A
2017-03-21
The aim of this study was to determine reference values for sarcopenia indices using different methods in healthy Saudi young men. Participants included 232 Saudi men aged between 20 and 35 years. The study measured anthropometric indices, blood pressure, hand grip strength, and lean muscle mass using dual-energy X-ray absorptiometry (DXA), and bioelectrical impedance analysis (BIA) was performed using Inbody 770 and Tanita 980 devices. Using DXA, the mean value of appendicular lean mass divided by the height squared (ALM/ht 2 ) was found to be 8.97 ± 1.23 kg/m 2 ; hand grip strength measured 42.8 ± 7.6 kg. While the differences between DXA and BIA (Tanita) were significant for all parameters, the differences between DXA and Inbody values were significant only for ALM parameters. Inbody sensitivity and specificity values were 73% and 95.9%, respectively. The kappa (P = 0.80) and p values (P < 0.001) showed good agreement between Inbody and DXA, whereas Tanita sensitivity and specificity values were 54.2% and 98.3%, respectively. Bland-Altman plots for differences in lean mass values between Tanita, Inbody, and DXA methods showed very high bias for Tanita and DXA, with significant differences (P < 0.001). The cut-off values for sarcopenia indices for Saudi young men are different from those of other ethnicities. The use of tailored cut-off reference values instead of a general cut-off for BIA devices is recommended.
Riley, Joseph L.; Gordan, Valeria V.; Rouisse, Kathleen M.; McClelland, Jocelyn; Gilbert, Gregg H.
2011-01-01
Objectives A number of articles have addressed gender differences in the productivity of dentists, but little is known about differences in practice patterns for caries management. This study compared the use of a comprehensive range of specific diagnostic methods, preventive agents, and restorative decision making for caries management between male and female dentists who were members of The Dental Practice-Based Research Network(DPBRN). Methods This study surveyed general dentists who were members of DPBRN and who practiced within the United States. The survey asked about dentist, practice, and patient characteristics, as well as prevention, assessment, and treatment of dental caries. Differences in years since dental school graduation, practice model, full/part-time status, and practice owner/employee were adjusted in the statistical models, before making conclusions about gender differences. Results Three hundred ninety-three male (84%) and seventy-three female (16%) dentists participated. Female dentists recommended at-home fluoride to a significantly larger proportion of their patients, whereas males had a preference for using in-office fluoride treatments with pediatric patients. Female dentists also choose to restore interproximal lesions at a significantly later stage of development, preferring to use preventive therapy more often at earlier stages of dental caries. There were few differences in diagnostic methods, time spent on or charges for restorative dentistry, and busyness of their practices. Conclusion DPBRN female dentists differ from their male counterparts in some aspects of the prevention, assessment, and treatment of dental caries, even with significant covariates taken into account. Practice patterns of female dentists suggest a greater caries preventive treatment philosophy. PMID:21454850
Wu, T-W; Cheng, F-P; Chen, I-H; Yang, C-H; Tsai, M-Y; Chang, M-H; Wang, J-H; Wu, J-T
2013-02-01
This study was to evaluate the combinatorial effect (14 treatments, A-N) of different Equex STM paste concentrations, cryoprotectants and the straw-freezing method on the post-thaw boar semen quality. Two ejaculates were collected from each of nine boars (three boars from each of three breeds). Semen was diluted in extenders with different concentrations of Equex STM paste and different cryoprotectants [glycerol or dimethylacetamide (DMA)] before cryopreserving via liquid nitrogen or dry ice. Motility, viability, percentage of spermatozoa with intense acrosomal staining and with normal morphology of post-thaw sperm were evaluated. The qualities of thawed semen were best preserved in treatment H (extender with 0.5% Equex STM paste and 5% glycerol and freezing by dry ice) and were worst in treatment B (extender with 0% Equex STM paste and 5% DMA and freezing by dry ice). Significant difference (p < 0.05) was present in post-thawed sperm motility (63% vs 27%), sperm viability (70% vs 33%) and sperm acrosomal integrity rate (68% vs 29%) between treatments H and B. However, sperm proportion with normal morphology showed no significant difference among treatments (66% vs 66%; p > 0.05). Moreover, statistical analysis suggests that no significant difference was present in semen quality among breed or individual donors (p > 0.05). These findings suggest that Equex STM paste improved the cryosurvival efficiency of boar sperm, and the favourable straw-freezing method changes between glycerol and DMA. © 2012 Blackwell Verlag GmbH.
Ozseven, Ayşe Gül; Sesli Çetin, Emel; Ozseven, Levent
2012-07-01
In recent years, owing to the presence of multi-drug resistant nosocomial bacteria, combination therapies are more frequently applied. Thus there is more need to investigate the in vitro activity of drug combinations against multi-drug resistant bacteria. Checkerboard synergy testing is among the most widely used standard technique to determine the activity of antibiotic combinations. It is based on microdilution susceptibility testing of antibiotic combinations. Although this test has a standardised procedure, there are many different methods for interpreting the results. In many previous studies carried out with multi-drug resistant bacteria, different rates of synergy have been reported with various antibiotic combinations using checkerboard technique. These differences might be attributed to the different features of the strains. However, different synergy rates detected by checkerboard method have also been reported in other studies using the same drug combinations and same types of bacteria. It was thought that these differences in synergy rates might be due to the different methods of interpretation of synergy test results. In recent years, multi-drug resistant Acinetobacter baumannii has been the most commonly encountered nosocomial pathogen especially in intensive-care units. For this reason, multidrug resistant A.baumannii has been the subject of a considerable amount of research about antimicrobial combinations. In the present study, the in vitro activities of frequently preferred combinations in A.baumannii infections like imipenem plus ampicillin/sulbactam, and meropenem plus ampicillin/sulbactam were tested by checkerboard synergy method against 34 multi-drug resistant A.baumannii isolates. Minimum inhibitory concentration (MIC) values for imipenem, meropenem and ampicillin/sulbactam were determined by the broth microdilution method. Subsequently the activity of two different combinations were tested in the dilution range of 4 x MIC and 0.03 x MIC in 96-well checkerboard plates. The results were obtained separately using the four different interpretation methods frequently preferred by researchers. Thus, it was aimed to detect to what extent the rates of synergistic, indifferent and antagonistic interactions were affected by different interpretation methods. The differences between the interpretation methods were tested by chi-square analysis for each combination used. Statistically significant differences were detected between the four different interpretation methods for the determination of synergistic and indifferent interactions (p< 0.0001). Highest rates of synergy were observed with both combinations by the method that used the lowest fractional inhibitory concentration index of all the non-turbid wells along the turbidity/non-turbidity interface. There was no statistically significant difference between the four methods for the detection of antagonism (p> 0.05). In conclusion although there is a standard procedure for checkerboard synergy testing it fails to exhibit standard results owing to different methods of interpretation of the results. Thus, there is a need to standardise the interpretation method for checkerboard synergy testing. To determine the most appropriate method of interpretation further studies investigating the clinical benefits of synergic combinations and additionally comparing the consistency of the results obtained from the other standard combination tests like time-kill studies, are required.
Imai, Arisa; Takamizawa, Toshiki; Sai, Keiichi; Tsujimoto, Akimasa; Nojiri, Kie; Endo, Hajime; Barkmeier, Wayne W; Latta, Mark A; Miyazaki, Masashi
2017-10-01
The aim of the present study was to determine the influence of different adhesive application methods and etching modes on enamel bond effectiveness of universal adhesives using shear bond strength (SBS) testing and surface free-energy (SFE) measurements. The adhesives Scotchbond Universal, All-Bond Universal, Adhese Universal, and G-Premio Bond were used. Prepared bovine enamel specimens were divided into four groups, based on type of adhesive, and subjected to the following surface treatments: (i) total-etch mode with active application; (ii) total-etch mode with inactive application; (iii) self-etch mode with active application; and (iv) self-etch mode with inactive application. Bonded specimens were subjected to SBS testing. The SFE of the enamel surfaces with adhesive was measured after rinsing with acetone and water. The SBS values in total-etch mode were significantly higher than those in self-etch mode. In total-etch mode, significantly lower SBS values were observed with active application compared with inactive application; in contrast, in self-etch mode there were no significant differences in SBS between active and inactive applications. A reduction in total SFE was observed for active application compared with inactive application. The interaction between etching mode and application method was statistically significant, and the application method significantly affected enamel bond strength in total-etch mode. © 2017 Eur J Oral Sci.
Boar taint detection: A comparison of three sensory protocols.
Trautmann, Johanna; Meier-Dinkel, Lisa; Gertheiss, Jan; Mörlein, Daniel
2016-01-01
While recent studies state an important role of human sensory methods for daily routine control of so-called boar taint, the evaluation of different heating methods is still incomplete. This study investigated three common heating methods (microwave (MW), hot-water (HW), hot-iron (HI)) for boar fat evaluation. The comparison was carried out on 72 samples with a 10-person sensory panel. The heating method significantly affected the probability of a deviant rating. Compared to an assumed 'gold standard' (chemical analysis), the performance was best for HI when both sensitivity and specificity were considered. The results show the superiority of the panel result compared to individual assessors. However, the consistency of the individual sensory ratings was not significantly different between MW, HW, and HI. The three protocols showed only fair to moderate agreement. Concluding from the present results, the hot-iron method appears to be advantageous for boar taint evaluation as compared to microwave and hot-water. Copyright © 2015. Published by Elsevier Ltd.
Multiple Comparisons of Observation Means--Are the Means Significantly Different?
ERIC Educational Resources Information Center
Fahidy, T. Z.
2009-01-01
Several currently popular methods of ascertaining which treatment (population) means are different, via random samples obtained under each treatment, are briefly described and illustrated by evaluating catalyst performance in a chemical reactor.
Wrestlers' minimal weight: anthropometry, bioimpedance, and hydrostatic weighing compared.
Oppliger, R A; Nielsen, D H; Vance, C G
1991-02-01
The need for accurate assessment of minimal wrestling weight among interscholastic wrestlers has been well documented. Previous research has demonstrated the validity of anthropometric methods for this purpose, but little research has examined the validity of bioelectrical impedance (BIA) measurements. Comparisons between BIA systems has received limited attention. With these two objectives, we compared the prediction of minimal weight (MW) among 57 interscholastic wrestlers using three anthropometric methods (skinfolds (SF) and two skeletal dimensions equations) and three BIA systems (Berkeley Medical Research (BMR), RJL, and Valhalla (VAL]. All methods showed high correlations (r values greater than 0.92) with hydrostatic weighting (HW) and between methods (r values greater than 0.90). The standard errors of estimate (SEE) were relatively small for all methods, especially for SF and the three BIA systems (SEE less than 0.70 kg). The total errors of prediction (E) for RJL and VAL (E = 4.4 and 3.9 kg) were significantly larger than observed nonsignificant BMR and SF values (E = 2.3 and 1.8 kg, respectively). Significant mean differences were observed between HW, RJL, VAL, and the two skeletal dimensions equations, but nonsignificant differences were observed between HW, BMR, and SF. BMR differed significantly from the RJL and VAL systems. The results suggest that RJL and VAL have potential application for this subpopulation. Prediction equation refinement with the addition of selected anthropometric measurement or moderating variables may enhance their utility. However, within the scope of our study, SF and BMR BIA appear to be the most valid methods for determining MW in interscholastic wrestlers.
Fatušić, Zlatan; Hudić, Igor; Sinanović, Osman; Kapidžić, Mirela; Hotić, Nešad; Musić, Asim
2011-09-01
To examine whether short-term postnatal health-related quality of life differed among women after different methods of cesarean sections. One hundred forty-five women were evaluated with previous CS (85 by Misgav Ladach and 60 by Pfannenstiel-Dörffler). Short-time quality of life was measured using the Croatian version of Short Form Health Survey (SF - 36). Short-term postoperative recovery was assessed using two criteria: febrile morbidity and degree of pain. Incidence of peritoneal adhesions was assigned using Bristow scoring system. Four weeks after delivery women with previous Misgav Ladach cesarean section significantly scored higher on the bodily pain (72.4 vs. 56.7, p < 0.05), social functioning (71.5 vs. 60.4, p < 0.05), and the vitality (61.7 vs. 50.3, p < 0.05) subscales. These differences disappeared in the second assessment (12-weeks postpartum) except in the bodily pain (74.7 vs. 61.2, p < 0.05) subscale. There was a significant trend toward a higher requirement for postoperative analgesics in the Pfannenstiel-Dörfler group (doses: 5.4 vs. 8.7, p < 0.05; hours: 17.9 vs. 23.3, p < 0.05), and they had a significantly higher rate of febrile morbidity than the Misgav Ladach group (5.7 vs. 9.4%, p < 0.05). Hospitalization time was reduced in the Misgav Ladach group (4.2 vs. 7.3, p <\\ 0.05). The incidence of adhesions was significantly lower in patients who had undergone a previous operation using the original Misgav Ladach method (0.47 vs. 0.77, p < 0.05). Misgav Ladach cesarean section method might lead to better short-time quality of life resulting in reducing postoperative complications compared to Pfannenstiel-Dörfler cesarean section method.
Norcross, J; Van Loan, M D
2004-01-01
Background: Pencil beam dual energy x ray absorptiometry (DXA) has been shown to provide valid estimates of body fat (%BF), but DXA fan beam technology has not been adequately tested to determine its validity. Objective: To compare %BF estimated from fan beam DXA with %BF determined using two and three compartment (2C, 3C) models. Methods: Men (n = 25) and women (n = 31), aged 18–41 years, participated in the study. Body density, from hydrostatic weighing, was used in the 2C estimate of %BF; DXA was used to determine bone mineral content (BMC) for the 3C estimate of %BF calculated using body density and BMC (3CBMC). DXA was also used to determine %BF. Analysis of variance was used to test for significant differences in %BF between sexes and among methods. Results: Women were significantly shorter, weighed less, had less fat free mass, and a higher %BF than men. No significant differences were found among methods (2C, 3CBMC, DXA) for determination of %BF in either sex. Although not significant, Bland-Altman plots showed that DXA gave higher values for %BF than the 2C and 3CBMC methods. Conclusion: DXA determination of %BF was not different from that of the 2C and 3CBMC models in this group of young adults. However, to validate fan beam DXA fully as a method for body composition assessment in a wide range of individuals and populations, comparisons are needed that use a 4C model with a measure of total body water and BMC. PMID:15273189
Tuna, Süleyman Hakan; Özçiçek Pekmez, Nuran; Kürkçüoğlu, Işin
2015-11-01
The effects of fabrication methods on the corrosion resistance of frameworks produced with Co-Cr alloys are not clear. The purpose of this in vitro study was to evaluate the electrochemical corrosion resistance of Co-Cr alloy specimens that were fabricated by conventional casting, milling, and laser sintering. The specimens fabricated with 3 different methods were investigated by potentiodynamic tests and electrochemical impedance spectroscopy in an artificial saliva. Ions released into the artificial saliva were estimated with inductively coupled plasma-mass spectrometry, and the results were statistically analyzed. The specimen surfaces were investigated with scanning electron microscopy before and after the tests. In terms of corrosion current and Rct properties, statistically significant differences were found both among the means of the methods and among the means of the material groups (P<.05). With regard to ions released, a statistically significant difference was found among the material groups (P<.05); however, no difference was found among the methods. Scanning electron microscopic imaging revealed that the specimens produced by conventional casting were affected to a greater extent by etching and electrochemical corrosion than those produced by milling and laser sintering. The corrosion resistance of a Co-Cr alloy specimens fabricated by milling or laser sintering was greater than that of the conventionally cast alloy specimens. The Co-Cr specimens produced by the same method also differed from one another in terms of corrosion resistance. These differences may be related to the variations in the alloy compositions. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Comparing the effects of reflexology and relaxation on fatigue in women with multiple sclerosis.
Nazari, Fatemeh; Shahreza, Mozhgan Soheili; Shaygannejad, Vahid; Valiani, Mahboubeh
2015-01-01
Fatigue is the most common and highly disabling symptom of multiple sclerosis (MS) that has negative effects on employment, the process of socialization, compliance with the disease, and other factors effective on activities of daily living. The usage of complementary and alternative medicine methods in MS patients is higher than in the general population. However, there is no scientific evidence to support their effectiveness. Therefore, this study aimed to compare the effects of reflexology and relaxation on fatigue in women with MS. This study is a single-blinded randomized clinical trial that was done on 75 patients with MS who referred to the MS Clinic of Ayatollah Kashani Hospital (Isfahan, Iran). After simple non-random sampling, participants were randomly assigned by minimization method to three groups: Reflexology, relaxation, and control groups (25 patients in each group). In the experimental groups, the interventions foot reflexology and relaxation (Jacobson and Benson) were performed for 4 weeks, twice a week for 40 min in each session, and the control group received care and routine medical treatment as directed by a physician. Data were collected through a questionnaire and the fatigue severity scale before, immediately after, and 2 months after interventions from all three groups. Data analysis was performed by SPSS version 18 using descriptive and inferential statistical methods. Findings obtained from analysis of variance (ANOVA) showed that there was no significant difference in the mean fatigue severity scores in the pre-interventions between the three groups (P > 0.05), but there was significant difference immediately after and 2 months after interventions between the three groups (P < 0.05). Findings obtained from repeated measures (ANOVA) showed that there was significant difference in the mean fatigue severity scores during different times between the three groups (P < 0.05), while this difference was not significant in the control group (P > 0.05). Furthermore, least significant difference post-hoc test revealed that the mean scores of fatigue severity immediately after intervention was lower in the reflexology group than in the other two groups and were lower in the relaxation group than in the control group; 2 months after interventions, the mean scores of fatigue severity were lower in the reflexology group than in the other two groups, but there was no significant difference between the two groups of relaxation and control (P > 0.05). It seems that both interventions were effective in reducing fatigue, but the effects of reflexology on reducing fatigue were more than those of relaxation. Hence, as these two methods are effective and affordable techniques, they can be recommended.
Kainz, Hans; Hajek, Martin; Modenese, Luca; Saxby, David J; Lloyd, David G; Carty, Christopher P
2017-03-01
In human motion analysis predictive or functional methods are used to estimate the location of the hip joint centre (HJC). It has been shown that the Harrington regression equations (HRE) and geometric sphere fit (GSF) method are the most accurate predictive and functional methods, respectively. To date, the comparative reliability of both approaches has not been assessed. The aims of this study were to (1) compare the reliability of the HRE and the GSF methods, (2) analyse the impact of the number of thigh markers used in the GSF method on the reliability, (3) evaluate how alterations to the movements that comprise the functional trials impact HJC estimations using the GSF method, and (4) assess the influence of the initial guess in the GSF method on the HJC estimation. Fourteen healthy adults were tested on two occasions using a three-dimensional motion capturing system. Skin surface marker positions were acquired while participants performed quite stance, perturbed and non-perturbed functional trials, and walking trials. Results showed that the HRE were more reliable in locating the HJC than the GSF method. However, comparison of inter-session hip kinematics during gait did not show any significant difference between the approaches. Different initial guesses in the GSF method did not result in significant differences in the final HJC location. The GSF method was sensitive to the functional trial performance and therefore it is important to standardize the functional trial performance to ensure a repeatable estimate of the HJC when using the GSF method. Copyright © 2017 Elsevier B.V. All rights reserved.
Improved method for selection of the NOAEL.
Calabrese, E J; Baldwin, L A
1994-02-01
The paper proposes that the NOAEL be defined as the highest dosage tested that is statistically significantly different from the control group while also being statistically significantly different from the LOAEL. This new definition requires that the NOAEL be defined from two points of reference rather than the current approach (i.e., single point of reference) in which the NOAEL represents only the highest dosage not statistically significantly different from the control group. This proposal is necessary in order to differentiate NOAELs which are statistically distinguishable from the LOAEL. Under the new regime only those satisfying both criteria would be designated a true NOAEL while those satisfying only one criteria (i.e., not statistically significant different from the control group) would be designated a "quasi" NOAEL and handled differently (i.e., via an uncertainty factor) for risk assessment purposes.
Statistical Significance vs. Practical Significance: An Exploration through Health Education
ERIC Educational Resources Information Center
Rosen, Brittany L.; DeMaria, Andrea L.
2012-01-01
The purpose of this paper is to examine the differences between statistical and practical significance, including strengths and criticisms of both methods, as well as provide information surrounding the application of various effect sizes and confidence intervals within health education research. Provided are recommendations, explanations and…
Yoon, Hyung-In; Bae, Ji-Won; Park, Ji-Man; Chun, Youn-Sic; Kim, Mi-Ae; Kim, Minji
2016-11-07
To assess if color measurement with intraoral scanner correlates with digital colorimeter and to evaluate the possibility of application of a digital scanner for shade selection. The L*a*b* values of the five shade tabs (A1, A2, A3, A3.5, and A4) were obtained with an intraoral scanner (TRIOS Pod) and a colorimeter (ShadeEye). Both devices were calibrated according to the manufacturer's instructions before measurements. Color measurement values were compared with paired t-test, and a Pearson's correlation analysis was performed to evaluate the relationship of two methods. The L*a*b* values of the colorimeter were significantly different from those of the digital scanner (p < 0.001). The L* and b* values of both methods were strongly correlated with each other (both p < 0.05). The device repeatability in both methods were reported to be excellent (p < 0.05). Within the limitations of this study, color measurements with digital intraoral scanners and computer-assisted image analysis were in accordance with those of the colorimeter with respect to L* and b* values; however, all the coordinates of shade tabs were significantly different between two methods. The digital intraoral scanner may not be used as the primary method of color selection in clinical practices, considering significant differences in color parameters with colorimeter. The scanner's capability in shade selection should be further evaluated. © 2016 by the American College of Prosthodontists.
Khare, Anshul Kumar; Abraham, Robinson J. J.; Appa Rao, V.; Babu, R. Narendra
2016-01-01
Aim: The present study was conducted to determine efficacy of edible coating of carrageenan and cinnamon oil to enhance the shelf life of chicken meat stored under refrigeration conditions. Materials and Methods: Chicken breast was coated with carrageenan and cinnamon oil by three methods of application viz., spraying brushing and dipping. The coated meat was evaluated for drip loss, pH, thiobarbituric acid number (TBA), tyrosine value (TV), extract release volume (ERV), Warner-Bratzler shear force value (WBSFV), instrumental color, microbiological, and sensory qualities as per standard procedures. Results: There was a significant difference observed for physicochemical parameters (pH, TBA, TV, ERV, drip loss and WBSFV) and microbiological analysis between storage periods in all the samples and between the control and treatments throughout the storage period but samples did not differed significantly for hunter color scores. However, there was no significant difference among three methods of application throughout the storage period though dipping had a lower rate of increase. A progressive decline in mean sensory scores was recorded along with the increase in storage time. Conclusion: The carrageenan and cinnamon edible coating was found to be a good alternative to enhance the shelf life of chicken meat under refrigeration conditions. It was also observed from study that dipping method of the application had comparatively higher shelf life than other methods of application. PMID:27051203
A comparison of two closely-related approaches to aerodynamic design optimization
NASA Technical Reports Server (NTRS)
Shubin, G. R.; Frank, P. D.
1991-01-01
Two related methods for aerodynamic design optimization are compared. The methods, called the implicit gradient approach and the variational (or optimal control) approach, both attempt to obtain gradients necessary for numerical optimization at a cost significantly less than that of the usual black-box approach that employs finite difference gradients. While the two methods are seemingly quite different, they are shown to differ (essentially) in that the order of discretizing the continuous problem, and of applying calculus, is interchanged. Under certain circumstances, the two methods turn out to be identical. We explore the relationship between these methods by applying them to a model problem for duct flow that has many features in common with transonic flow over an airfoil. We find that the gradients computed by the variational method can sometimes be sufficiently inaccurate to cause the optimization to fail.
NASA Astrophysics Data System (ADS)
Jinghai, Zhou; Tianbei, Kang; Fengchi, Wang; Xindong, Wang
2017-11-01
Eight less stirrups in the core area frame joints are simulated by ABAQUS finite element numerical software. The composite reinforcement method is strengthened with carbon fiber and increasing column section, the axial compression ratio of reinforced specimens is 0.3, 0.45 and 0.6 respectively. The results of the load-displacement curve, ductility and stiffness are analyzed, and it is found that the different axial compression ratio has great influence on the bearing capacity of increasing column section strengthening method, and has little influence on carbon fiber reinforcement method. The different strengthening schemes improve the ultimate bearing capacity and ductility of frame joints in a certain extent, composite reinforcement joints strengthening method to improve the most significant, followed by increasing column section, reinforcement method of carbon fiber reinforced joints to increase the minimum.
Defects in ZnO nanorods prepared by a hydrothermal method.
Tam, K H; Cheung, C K; Leung, Y H; Djurisić, A B; Ling, C C; Beling, C D; Fung, S; Kwok, W M; Chan, W K; Phillips, D L; Ding, L; Ge, W K
2006-10-26
ZnO nanorod arrays were fabricated using a hydrothermal method. The nanorods were studied by scanning electron microscopy, photoluminescence (PL), time-resolved PL, X-ray photoelectron spectroscopy, and positron annihilation spectroscopy before and after annealing in different environments and at different temperatures. Annealing atmosphere and temperature had significant effects on the PL spectrum, while in all cases the positron diffusion length and PL decay times were increased. We found that, while the defect emission can be significantly reduced by annealing at 200 degrees C, the rods still have large defect concentrations as confirmed by their low positron diffusion length and short PL decay time constants.
Localized Energy-Based Normalization of Medical Images: Application to Chest Radiography.
Philipsen, R H H M; Maduskar, P; Hogeweg, L; Melendez, J; Sánchez, C I; van Ginneken, B
2015-09-01
Automated quantitative analysis systems for medical images often lack the capability to successfully process images from multiple sources. Normalization of such images prior to further analysis is a possible solution to this limitation. This work presents a general method to normalize medical images and thoroughly investigates its effectiveness for chest radiography (CXR). The method starts with an energy decomposition of the image in different bands. Next, each band's localized energy is scaled to a reference value and the image is reconstructed. We investigate iterative and local application of this technique. The normalization is applied iteratively to the lung fields on six datasets from different sources, each comprising 50 normal CXRs and 50 abnormal CXRs. The method is evaluated in three supervised computer-aided detection tasks related to CXR analysis and compared to two reference normalization methods. In the first task, automatic lung segmentation, the average Jaccard overlap significantly increased from 0.72±0.30 and 0.87±0.11 for both reference methods to with normalization. The second experiment was aimed at segmentation of the clavicles. The reference methods had an average Jaccard index of 0.57±0.26 and 0.53±0.26; with normalization this significantly increased to . The third experiment was detection of tuberculosis related abnormalities in the lung fields. The average area under the Receiver Operating Curve increased significantly from 0.72±0.14 and 0.79±0.06 using the reference methods to with normalization. We conclude that the normalization can be successfully applied in chest radiography and makes supervised systems more generally applicable to data from different sources.
NASA Astrophysics Data System (ADS)
Dobbs, Vicki
Significant numbers of students fail high school chemistry, preventing them from graduating. Starting in the 2013-2014 school year, 100% of the students must pass a science assessment for schools to meet Adequate Yearly Progress (AYP) in accordance to No Child Left Behind (NCLB). Failure to meet AYP results in sanctions, such as state management or closure of a school or replacing a school staff. The purpose of this study was to determine whether the teaching strategy, Problem Based Learning (PBL), will improve student achievement in high school chemistry to a greater degree than traditional teaching methods. PBL is a student-centered, inquiry-based teaching method based on the constructivist learning theory. The research question looked at whether there was a difference in student achievement between students a high school chemistry classroom using PBL and students in a classroom using traditional teaching methods as measured by scores on a 20-question quiz. The research study used a quasi-experimental pretest/posttest control group design. An independent samples t-test compared gains scores between the pretest and posttest. Analysis of quiz scores indicated that there was not a significant difference (t(171) = 1.001, p = .318) in student achievement between the teaching methods. Because there was not a significant difference, each teacher can decide which teaching method best suites the subject matter and the learning styles of the students. This study adds research based data to help teachers and schools choose one teaching method over another so that students may gain knowledge, develop problem-solving skills, and life-long learning skills that will bring about social change in the form of a higher quality of life for the students and community as a whole.
Tanner, Hannah; Evans, Jason T; Gossain, Savita; Hussain, Abid
2017-01-18
Patient mortality is significantly reduced by rapid identification of bacteria from sterile sites. MALDI-TOF can identify bacteria directly from positive blood cultures and multiple sample preparation methods are available. We evaluated three sample preparation methods and two MALDI-TOF score cut-off values. Positive blood culture bottles with organisms present in Gram stains were prospectively analysed by MALDI-TOF. Three lysis reagents (Saponin, SDS, and SepsiTyper lysis bufer) were applied to each positive culture followed by centrifugation, washing and protein extraction steps. Methods were compared using the McNemar test and 16S rDNA sequencing was used to assess discordant results. In 144 monomicrobial cultures, using ≥2.000 as the cut-off value, species level identifications were obtained from 69/144 (48%) samples using Saponin, 86/144 (60%) using SDS, and 91/144 (63%) using SepsiTyper. The difference between SDS and SepsiTyper was not statistically significant (P = 0.228). Differences between Saponin and the other two reagents were significant (P < 0.01). Using ≥1.700 plus top three results matching as the cut-off value, species level identifications were obtained from 100/144 (69%) samples using Saponin, 103/144 (72%) using SDS, and 106/144 (74%) using SepsiTyper and there was no statistical difference between the methods. No true discordances between culture and direct MALDI-TOF identification were observed in monomicrobial cultures. In 32 polymicrobial cultures, MALDI-TOF identified one organism in 34-75% of samples depending on the method. This study demonstrates two inexpensive in-house detergent lysis methods are non-inferior to a commercial kit for analysis of positive blood cultures by direct MALDI-TOF in a clinical diagnostic microbiology laboratory.
Wang, Guangzhou; Wang, Jiefei; Huang, Nannan; Yu, Fengqin
2016-01-01
In this paper, the clinical value of the detection about serum and unconjugated bilirubin (UCB) in neonatal jaundice was studied to found an effective and rapid method for diagnose of neonatal jaundice. ALB (Serum Albumin), total serum bilirubin (TSB) and UCB were detected by ELISA method among the 100 cases with neonatal jaundice selected for the study. The values of ALB, UCB and TSB in moderate jaundice patients were (42.83±3.87) g/L, (287.35±44.38) μm/L, (304.16±43.40) μm/L, respectively; as for the severe jaundice patients, the values were (38.41±4.82) g/L, (354.38±48.75) μm/L, (375.20±47.51) μm/L. The results showed significant differences with the p< 0.05 between moderate and severe jaundice patients. The level of ALB, UCB, TSB in hemolytic jaundice, obstructive jaundice and jaundice caused by other infections also had significant differences, and the difference was statistically significant (p<0.05). The detection of ALB and UCB provides a useful method for the diagnosis and assessment of neonatal jaundice.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Weili; Department of Radiation Oncology, the Fourth Affiliated Hospital, China Medical University, Shenyang; Xu, Yaping
2013-08-01
Purpose: This study aimed to compare lung dose–volume histogram (DVH) parameters such as mean lung dose (MLD) and the lung volume receiving ≥20 Gy (V20) of commonly used definitions of normal lung in terms of tumor/target subtraction and to determine to what extent they differ in predicting radiation pneumonitis (RP). Methods and Materials: One hundred lung cancer patients treated with definitive radiation therapy were assessed. The gross tumor volume (GTV) and clinical planning target volume (PTV{sub c}) were defined by the treating physician and dosimetrist. For this study, the clinical target volume (CTV) was defined as GTV with 8-mm uniformmore » expansion, and the PTV was defined as CTV with an 8-mm uniform expansion. Lung DVHs were generated with exclusion of targets: (1) GTV (DVH{sub G}); (2) CTV (DVH{sub C}); (3) PTV (DVH{sub P}); and (4) PTV{sub c} (DVH{sub Pc}). The lung DVHs, V20s, and MLDs from each of the 4 methods were compared, as was their significance in predicting radiation pneumonitis of grade 2 or greater (RP2). Results: There are significant differences in dosimetric parameters among the various definition methods (all Ps<.05). The mean and maximum differences in V20 are 4.4% and 12.6% (95% confidence interval 3.6%-5.1%), respectively. The mean and maximum differences in MLD are 3.3 Gy and 7.5 Gy (95% confidence interval, 1.7-4.8 Gy), respectively. MLDs of all methods are highly correlated with each other and significantly correlated with clinical RP2, although V20s are not. For RP2 prediction, on the receiver operating characteristic curve, MLD from DVH{sub G} (MLD{sub G}) has a greater area under curve of than MLD from DVH{sub C} (MLD{sub C}) or DVH{sub P} (MLD{sub P}). Limiting RP2 to 30%, the threshold is 22.4, 20.6, and 18.8 Gy, for MLD{sub G}, MLD{sub C}, and MLD{sub P}, respectively. Conclusions: The differences in MLD and V20 from various lung definitions are significant. MLD from the GTV exclusion method may be more accurate in predicting clinical significant radiation pneumonitis.« less
Lee, Sang Hun; Yoo, Myung Hoon; Park, Jun Woo; Kang, Byung Chul; Yang, Chan Joo; Kang, Woo Suk; Ahn, Joong Ho; Chung, Jong Woo; Park, Hong Ju
2018-06-01
To evaluate whether video head impulse test (vHIT) gains are dependent on the measuring device and method of analysis. Prospective study. vHIT was performed in 25 healthy subjects using two devices simultaneously. vHIT gains were compared between these instruments and using five different methods of comparing position and velocity gains during head movement intervals. The two devices produced different vHIT gain results with the same method of analysis. There were also significant differences in the vHIT gains measured using different analytical methods. The gain analytic method that compares the areas under the velocity curve (AUC) of the head and eye movements during head movements showed lower vHIT gains than a method that compared the peak velocities of the head and eye movements. The former method produced the vHIT gain with the smallest standard deviation among the five procedures tested in this study. vHIT gains differ in normal subjects depending on the device and method of analysis used, suggesting that it is advisable for each device to have its own normal values. Gain calculations that compare the AUC of the head and eye movements during the head movements show the smallest variance.
Tang, Minmin; Xia, Qiuyu; Holland, Brendan J; Wang, Hui; Zhang, Yufeng; Li, Rui; Cao, Hongxing
2017-12-01
This study selected 5 methods, including boiling, hot air drying, high-pressurized steam, freezing, and microwave radiation to pretreat fresh oil palm fruit before solvent extraction of the oil. Using fresh fruit as a control, the pretreatment methods were compared for the effects on the activity of the 2 main enzymes in the fruit and some physicochemical properties of the crude palm oil. The results indicated, although all the 5 pretreatments could inactivate lipase and peroxidase in the treated flesh significantly (P < 0.05), the high-pressurized steam was the most effective. There were also differences in the unsaturated fatty acid contents of the 6 oils. The crude oil from frozen fruit contained significantly more vitamin E (37829.33 ppm) than previously reported. Microwave radiation was shown to significantly decrease the free fatty acid content and the peroxide value, while increasing the oxidative stability index. Thermal behaviors of the oils were significantly different to each other with the exception a few parameters (P < 0.05). © 2017 Institute of Food Technologists®.
Comparison of preprocessing methods and storage times for touch DNA samples
Dong, Hui; Wang, Jing; Zhang, Tao; Ge, Jian-ye; Dong, Ying-qiang; Sun, Qi-fan; Liu, Chao; Li, Cai-xia
2017-01-01
Aim To select appropriate preprocessing methods for different substrates by comparing the effects of four different preprocessing methods on touch DNA samples and to determine the effect of various storage times on the results of touch DNA sample analysis. Method Hand touch DNA samples were used to investigate the detection and inspection results of DNA on different substrates. Four preprocessing methods, including the direct cutting method, stubbing procedure, double swab technique, and vacuum cleaner method, were used in this study. DNA was extracted from mock samples with four different preprocessing methods. The best preprocess protocol determined from the study was further used to compare performance after various storage times. DNA extracted from all samples was quantified and amplified using standard procedures. Results The amounts of DNA and the number of alleles detected on the porous substrates were greater than those on the non-porous substrates. The performances of the four preprocessing methods varied with different substrates. The direct cutting method displayed advantages for porous substrates, and the vacuum cleaner method was advantageous for non-porous substrates. No significant degradation trend was observed as the storage times increased. Conclusion Different substrates require the use of different preprocessing method in order to obtain the highest DNA amount and allele number from touch DNA samples. This study provides a theoretical basis for explorations of touch DNA samples and may be used as a reference when dealing with touch DNA samples in case work. PMID:28252870
Redlich, A; Köppe, I
2001-11-01
A new technical variant of caesarean section was described a few years ago, which is characterised by blunt surgical preparation and simplified seam technique. A prospective investigation compared the differences in the surgery and postoperative process as well as the rate of complications between this Misgav Ladach method and the conventional technique of Sectio. The individual postoperative well-being of the women was recorded by visual analog scales. - Women, whom realize the including criterias (first caesarean section, >/= 32. week of pregnancy, one baby), were examined in this study over one year: 105 patients operated with the Misgav Ladach method and 67 conventionally operated patients. The patients were randomized in a function of the first letter of the surname (A-K: Misgav-Ladach method; L-Z: classical technique). - The surgical time from the cut to the seam was significantly shorter (29.8 vs. 49.3 min; p < 0,001) in the Misgav Ladach group. There were no differences between the two methods in the rate of postoperative complications. The febrile morbidity was equivalent in both groups (7.6 % vs. 9 %), likewise the frequency of postoperative hematomas (3.8 % vs. 3 %). The postoperative period with consumption of analgetics was significantly longer in the group of conventionally operated patients (1.9 d vs. 2.4 d; p < 0.01). The postoperative presentness was estimated significantly better (p < 0,.01) by the patients of the Misgav ladach group - probably caused by the significantly earlier mobilization (p < 0.05). - The surgical technique described by Misgav and Ladach allows a safe execution of the caesarean section and represents an alternative to the conventional method. The duration of operation (cut-seam-time) was significantly shorter. The technique of less traumatising of tissue caused a significantly earlier mobilisation and a significantly shorter requirement of analgetics. The women estimated her postoperative physical condition as better.
MAVTgsa: An R Package for Gene Set (Enrichment) Analysis
Chien, Chih-Yi; Chang, Ching-Wei; Tsai, Chen-An; ...
2014-01-01
Gene semore » t analysis methods aim to determine whether an a priori defined set of genes shows statistically significant difference in expression on either categorical or continuous outcomes. Although many methods for gene set analysis have been proposed, a systematic analysis tool for identification of different types of gene set significance modules has not been developed previously. This work presents an R package, called MAVTgsa, which includes three different methods for integrated gene set enrichment analysis. (1) The one-sided OLS (ordinary least squares) test detects coordinated changes of genes in gene set in one direction, either up- or downregulation. (2) The two-sided MANOVA (multivariate analysis variance) detects changes both up- and downregulation for studying two or more experimental conditions. (3) A random forests-based procedure is to identify gene sets that can accurately predict samples from different experimental conditions or are associated with the continuous phenotypes. MAVTgsa computes the P values and FDR (false discovery rate) q -value for all gene sets in the study. Furthermore, MAVTgsa provides several visualization outputs to support and interpret the enrichment results. This package is available online.« less
Comparing deflection measurements of a magnetically steerable catheter using optical imaging and MRI
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lillaney, Prasheel, E-mail: Prasheel.Lillaney@ucsf.edu; Caton, Curtis; Martin, Alastair J.
2014-02-15
Purpose: Magnetic resonance imaging (MRI) is an emerging modality for interventional radiology, giving clinicians another tool for minimally invasive image-guided interventional procedures. Difficulties associated with endovascular catheter navigation using MRI guidance led to the development of a magnetically steerable catheter. The focus of this study was to mechanically characterize deflections of two different prototypes of the magnetically steerable catheterin vitro to better understand their efficacy. Methods: A mathematical model for deflection of the magnetically steerable catheter is formulated based on the principle that at equilibrium the mechanical and magnetic torques are equal to each other. Furthermore, two different image basedmore » methods for empirically measuring the catheter deflection angle are presented. The first, referred to as the absolute tip method, measures the angle of the line that is tangential to the catheter tip. The second, referred to the base to tip method, is an approximation that is used when it is not possible to measure the angle of the tangent line. Optical images of the catheter deflection are analyzed using the absolute tip method to quantitatively validate the predicted deflections from the mathematical model. Optical images of the catheter deflection are also analyzed using the base to tip method to quantitatively determine the differences between the absolute tip and base to tip methods. Finally, the optical images are compared to MR images using the base to tip method to determine the accuracy of measuring the catheter deflection using MR. Results: The optical catheter deflection angles measured for both catheter prototypes using the absolute tip method fit very well to the mathematical model (R{sup 2} = 0.91 and 0.86 for each prototype, respectively). It was found that the angles measured using the base to tip method were consistently smaller than those measured using the absolute tip method. The deflection angles measured using optical data did not demonstrate a significant difference from the angles measured using MR image data when compared using the base to tip method. Conclusions: This study validates the theoretical description of the magnetically steerable catheter, while also giving insight into different methods and modalities for measuring the deflection angles of the prototype catheters. These results can be used to mechanically model future iterations of the design. Quantifying the difference between the different methods for measuring catheter deflection will be important when making deflection measurements in future studies. Finally, MR images can be used to reliably measure deflection angles since there is no significant difference between the MR and optical measurements.« less
Hemispheric preference and progressive-part or whole practice in beginning typewriting.
Johns, L B
1989-04-01
This investigation explored the interaction of progressive-part versus whole methods of practice with hemispheric preference for processing information and the impact of each upon high school students' speed and accuracy in beginning typewriting. Zenhausern's Differential Hemispheric Activation Test was scored in such a way that it was possible to plot the scores along a continuum. Analysis of variance gave significant F ratios on 3 of the 4 testing days. The continuous scores were divided into five categories: middle, left moderates, right moderates, extreme rights, and extreme lefts. The moderate-left group speed was consistently the fastest group, and the extreme rights were consistently the slowest group. This difference was significant for all four testing days with the moderate-left mean speed varying between 4 to 6 words per minute faster each testing day. The extreme rights were consistently the most accurate, even though not statistically significantly so. There was no significant difference between method of practice and typewriting speed or between method of practice and typewriting accuracy; however, on all four testing days the mean gross speed of the whole practice learning group was 0.73 to 0.99 words per minute faster than the progressive-part group. A two-way analysis of variance indicated no interaction between method or practice and hemispheric preference.
Advances in analytical methodologies to guide bioprocess engineering for bio-therapeutics.
Saldova, Radka; Kilcoyne, Michelle; Stöckmann, Henning; Millán Martín, Silvia; Lewis, Amanda M; Tuite, Catherine M E; Gerlach, Jared Q; Le Berre, Marie; Borys, Michael C; Li, Zheng Jian; Abu-Absi, Nicholas R; Leister, Kirk; Joshi, Lokesh; Rudd, Pauline M
2017-03-01
This study was performed to monitor the glycoform distribution of a recombinant antibody fusion protein expressed in CHO cells over the course of fed-batch bioreactor runs using high-throughput methods to accurately determine the glycosylation status of the cell culture and its product. Three different bioreactors running similar conditions were analysed at the same five time-points using the advanced methods described here. N-glycans from cell and secreted glycoproteins from CHO cells were analysed by HILIC-UPLC and MS, and the total glycosylation (both N- and O-linked glycans) secreted from the CHO cells were analysed by lectin microarrays. Cell glycoproteins contained mostly high mannose type N-linked glycans with some complex glycans; sialic acid was α-(2,3)-linked, galactose β-(1,4)-linked, with core fucose. Glycans attached to secreted glycoproteins were mostly complex with sialic acid α-(2,3)-linked, galactose β-(1,4)-linked, with mostly core fucose. There were no significant differences noted among the bioreactors in either the cell pellets or supernatants using the HILIC-UPLC method and only minor differences at the early time-points of days 1 and 3 by the lectin microarray method. In comparing different time-points, significant decreases in sialylation and branching with time were observed for glycans attached to both cell and secreted glycoproteins. Additionally, there was a significant decrease over time in high mannose type N-glycans from the cell glycoproteins. A combination of the complementary methods HILIC-UPLC and lectin microarrays could provide a powerful and rapid HTP profiling tool capable of yielding qualitative and quantitative data for a defined biopharmaceutical process, which would allow valuable near 'real-time' monitoring of the biopharmaceutical product. Copyright © 2016 Elsevier Inc. All rights reserved.
A Comparison of Two Balance Calibration Model Building Methods
NASA Technical Reports Server (NTRS)
DeLoach, Richard; Ulbrich, Norbert
2007-01-01
Simulated strain-gage balance calibration data is used to compare the accuracy of two balance calibration model building methods for different noise environments and calibration experiment designs. The first building method obtains a math model for the analysis of balance calibration data after applying a candidate math model search algorithm to the calibration data set. The second building method uses stepwise regression analysis in order to construct a model for the analysis. Four balance calibration data sets were simulated in order to compare the accuracy of the two math model building methods. The simulated data sets were prepared using the traditional One Factor At a Time (OFAT) technique and the Modern Design of Experiments (MDOE) approach. Random and systematic errors were introduced in the simulated calibration data sets in order to study their influence on the math model building methods. Residuals of the fitted calibration responses and other statistical metrics were compared in order to evaluate the calibration models developed with different combinations of noise environment, experiment design, and model building method. Overall, predicted math models and residuals of both math model building methods show very good agreement. Significant differences in model quality were attributable to noise environment, experiment design, and their interaction. Generally, the addition of systematic error significantly degraded the quality of calibration models developed from OFAT data by either method, but MDOE experiment designs were more robust with respect to the introduction of a systematic component of the unexplained variance.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feng, Y; Huang, Z; Lo, S
2015-06-15
Purpose: To improve Gamma Knife SRS treatment efficiency for brain metastases and compare the differences of treatment time and radiobiological effects between two different planning methods of automatic filling and manual placement of shots with inverse planning. Methods: T1-weighted MRI images with gadolinium contrast from five patients with a single brain metastatic-lesion were used in this retrospective study. Among them, two were from primary breast cancer, two from primary melanoma cancer and one from primary prostate cancer. For each patient, two plans were generated in Leksell GammaPlan10.1.1 for radiosurgical treatment with a Leksell GammaKnife Perfexion machine: one with automatic filling,more » automatic sector configuration and inverse optimization (Method1); and the other with manual placement of shots, manual setup of collimator sizes, manual setup of sector blocking and inverse optimization (Method2). Dosimetric quality of the plans was evaluated with parameters of Coverage, Selectivity, Gradient-Index and DVH. Beam-on Time, Number-of-Shots and Tumor Control Probability(TCP) were compared for the two plans while keeping their dosimetric quality very similar. Relative reduction of Beam-on Time and Number-of-Shots were calculated as the ratios among the two plans and used for quantitative analysis. Results: With very similar dosimetric and radiobiological plan quality, plans created with Method 2 had significantly reduced treatment time. Relative reduction of Beam-on Time ranged from 20% to 51 % (median:29%,p=0.001), and reduction of Number-of-Shots ranged from 5% to 67% (median:40%,p=0.0002), respectively. Time of plan creation for Method1 and Method2 was similar, approximately 20 minutes, excluding the time for tumor delineation. TCP calculated for the tumors from differential DVHs did not show significant difference between the two plans (p=0.35). Conclusion: The method of manual setup combined with inverse optimization in LGP for treatment of brain metastatic lesions with the Perfexion can achieve significantly higher time efficiency without degrading treatment quality.« less
Montero, Manuela M Haro; Vicente, Ascensión; Alfonso-Hernández, Noelia; Jiménez-López, Manuel; Bravo-González, Luis-Alberto
2015-05-01
To evaluate in vitro the shear bond strength of brackets recycled by sandblasting with aluminum oxide particles of different sizes or reconditioned industrially after successive rebonding. Eighty brackets were bonded and debonded sequentially three times. After the first debonding, brackets were divided into four groups: (group 1) sandblasting with aluminum oxide particles of 25 μ, (group 2) 50 μ, and (group 3) 110 μ, and (group 4) industrial recycling. Bond strength and adhesive material remaining on debonded bracket bases were evaluated for each successive debond. No significant differences were detected between the four groups following the first recycle (P > .05). After the second recycle, bond strength was significantly greater for the industrially recycled group than the other groups (P < .016). When shear bond strength was compared within each recycling method, the bond strength of sandblasted brackets decreased with the increase of particle size and with each recycle; for the industrially recycled group, no significant differences were detected between the three sequences (P > .016). In the evaluation of bond material remnant, the industrially recycled group left significantly less bond material after successive recycling than the other groups did (P < .016). Within each recycling method, the adhesive remnant decreased significantly after successive debond (P < .016). Industrial recycling obtained better results than sandblasting after three successive debondings. The brackets' shear bond strength decreased as the size of the aluminum oxide particle used for sandblasting increased and as recycling was repeated.
Teich, Sorin; Al-Rawi, Wisam; Heima, Masahiro; Faddoul, Fady F; Goldzweig, Gil; Gutmacher, Zvi; Aizenbud, Dror
2016-10-01
To evaluate the image quality generated by eight commercially available intraoral sensors. Eighteen clinicians ranked the quality of a bitewing acquired from one subject using eight different intraoral sensors. Analytical methods used to evaluate clinical image quality included the Visual Grading Characteristics method, which helps to quantify subjective opinions to make them suitable for analysis. The Dexis sensor was ranked significantly better than Sirona and Carestream-Kodak sensors; and the image captured using the Carestream-Kodak sensor was ranked significantly worse than those captured using Dexis, Schick and Cyber Medical Imaging sensors. The Image Works sensor image was rated the lowest by all clinicians. Other comparisons resulted in non-significant results. None of the sensors was considered to generate images of significantly better quality than the other sensors tested. Further research should be directed towards determining the clinical significance of the differences in image quality reported in this study. © 2016 FDI World Dental Federation.
Arginase distribution in tissues of domestic animals.
Aminlari, M; Vaseghi, T
1992-10-01
1. A new colorimetric method was used for determination of arginase in different tissues of some domestic animals. 2. In all species studied liver was the richest source of arginase. 3. Significant differences were observed in the specific activity of arginase in livers from different species. 4. In all species, besides liver, kidney and brain also contained significant levels of arginase. 5. In the dog, in addition to the three organs mentioned above, lung, heart, spleen and skeletal muscle showed some arginase activity. 6. In sheep and cattle significant arginase activity was observed in the rumen. No differences were observed between epithelial and muscular layers of different parts of digestive system in all species studied. 7. These results are discussed in terms of the possible role of arginase in different tissues of animals.
Wu, Yazhou; He, Qinghua; Huang, Hua; Zhang, Ling; Zhuo, Yu; Xie, Qi; Wu, Baoming
2008-10-01
This is a research carried out to explore a pragmatic way of BCI based imaging movement, i. e. to extract the feature of EEG for reflecting different thinking by searching suitable methods of signal extraction and recognition algorithm processing, to boost the recognition rate of communication for BCI system, and finally to establish a substantial theory and experimental support for BCI application. In this paper, different mental tasks for imaging left-right hands movement from 6 subjects were studied in three different time sections (hint keying at 2s, 1s and 0s after appearance of arrow). Then we used wavelet analysis and Feed-forward Back-propagation Neural Network (BP-NN) method for processing and analyzing the experimental data of off-line. Delay time delta t2, delta t1 and delta t0 for all subjects in the three different time sections were analyzed. There was significant difference between delta to and delta t2 or delta t1 (P<0.05), but no significant difference was noted between delta t2 and delta t1 (P>0.05). The average results of recognition rate were 65%, 86.67% and 72%, respectively. There were obviously different features for imaging left-right hands movement about 0.5-1s before actual movement; these features displayed significant difference. We got higher recognition rate of communication under the hint keying at about 1s after the appearance of arrow. These showed the feasibility of using the feature signals extracted from the project as the external control signals for BCI system, and demon strated that the project provided new ideas and methods for feature extraction and classification of mental tasks for BCI.
Karn, Pankaj Ranjan; Cho, Wonkyung; Park, Hee-Jun; Park, Jeong-Sook; Hwang, Sung-Joo
2013-01-01
A novel method to prepare cyclosporin A encapsulated liposomes was introduced using supercritical fluid of carbon dioxide (SCF-CO2) as an antisolvent. To investigate the strength of the newly developed SCF-CO2 method compared with the modified conventional Bangham method, particle size, zeta potential, and polydispersity index (PDI) of both liposomal formulations were characterized and compared. In addition, entrapment efficiency (EE) and drug loading (DL) characteristics were analyzed by reversed-phase high-performance liquid chromatography. Significantly larger particle size and PDI were revealed from the conventional method, while EE (%) and DL (%) did not exhibit any significant differences. The SCF-CO2 liposomes were found to be relatively smaller, multilamellar, and spherical with a smoother surface as determined by transmission electron microscopy. SCF-CO2 liposomes showed no significant differences in their particle size and PDI after more than 3 months, whereas conventional liposomes exhibited significant changes in their particle size. The initial yield (%), EE (%), and DL (%) of SCF-CO2 liposomes and conventional liposomes were 90.98 ± 2.94, 92.20 ± 1.36, 20.99 ± 0.84 and 90.72 ± 2.83, 90.24 ± 1.37, 20.47 ± 0.94, respectively, which changed after 14 weeks to 86.65 ± 0.30, 87.63 ± 0.72, 18.98 ± 0.22 and 75.04 ± 8.80, 84.59 ± 5.13, 15.94 ± 2.80, respectively. Therefore, the newly developed SCF-CO2 method could be a better alternative compared with the conventional method and may provide a promising approach for large-scale production of liposomes. PMID:23378759
[Interlaboratory Study on Evaporation Residue Test for Food Contact Products (Report 2)].
Ohno, Hiroyuki; Mutsuga, Motoh; Abe, Tomoyuki; Abe, Yutaka; Amano, Homare; Ishihara, Kinuyo; Ohsaka, Ikue; Ohno, Haruka; Ohno, Yuichiro; Ozaki, Asako; Kakihara, Yoshiteru; Kobayashi, Hisashi; Sakuragi, Hiroshi; Shibata, Hiroshi; Shirono, Katsuhiro; Sekido, Haruko; Takasaka, Noriko; Takenaka, Yu; Tajima, Yoshiyasu; Tanaka, Aoi; Tanaka, Hideyuki; Nakanishi, Toru; Nomura, Chie; Haneishi, Nahoko; Hayakawa, Masato; Miura, Toshihiko; Yamaguchi, Miku; Yamada, Kyohei; Watanabe, Kazunari; Sato, Kyoko
2018-01-01
An interlaboratory study was performed to evaluate the equivalence between an official method and a modified method of evaporation residue test using heptane as a food-simulating solvent for oily or fatty foods, based on the Japanese Food Sanitation Law for food contact products. Twenty-three laboratories participated, and tested the evaporation residues of nine test solutions as blind duplicates. In the official method, heating for evaporation was done with a water bath. In the modified method, a hot plate was used for evaporation, and/or a vacuum concentration procedure was skipped. In most laboratories, the test solutions were heated until just prior to dryness, and then allowed to dry under residual heat. Statistical analysis revealed that there was no significant difference between the two methods. Accordingly, the modified method provides performance equal to the official method, and is available as an alternative method. Furthermore, an interlaboratory study was performed to evaluate and compare two leaching solutions (95% ethanol and isooctane) used as food-simulating solvents for oily or fatty foods in the EU. The results demonstrated that there was no significant difference between heptane and these two leaching solutions.
Exposure of the surgeon's hands to radiation during hand surgery procedures.
Żyluk, Andrzej; Puchalski, Piotr; Szlosser, Zbigniew; Dec, Paweł; Chrąchol, Joanna
2014-01-01
The objective of the study was to assess the time of exposure of the surgeon's hands to radiation and calculate of the equivalent dose absorbed during surgery of hand and wrist fractures with C-arm fluoroscope guidance. The necessary data specified by the objective of the study were acquired from operations of 287 patients with fractures of fingers, metacarpals, wrist bones and distal radius. 218 operations (78%) were percutaneous procedures and 60 (22%) were performed by open method. Data on the time of exposure and dose of radiation were acquired from the display of the fluoroscope, where they were automatically generated. These data were assigned to the individual patient, type of fracture, method of surgery and the operating surgeon. Fixations of distal radial fractures required longer times of radiation exposure (mean 61 sec.) than fractures of the wrist/metacarpals and fingers (38 and 32 sec., respectively), which was associated with absorption of significantly higher equivalent doses. Fixations of distal radial fractures by open method were associated with statistically significantly higher equivalent doses (0.41 mSv) than percutaneous procedures (0.3 mSv). Fixations of wrist and metacarpal bone fractures by open method were associated with lower equivalent doses (0.34 mSv) than percutaneous procedures (0.37 mSv),but the difference was not significant. Fixations of finger fractures by open method were associated with lower equivalent doses (0.13 mSv) than percutaneous procedures (0.24 mSv), the difference being statistically non-significant. Statistically significant differences in exposure time and equivalent doses were noted between 4 surgeons participating in the study, but no definitive relationship was found between these parameters and surgeons' employment time. 1. Hand surgery procedures under fluoroscopic guidance are associated with mild exposure of the surgeons' hands to radiation. 2. The equivalent dose was related to the type of fracture, operative technique and - to some degree - to the time of employment of the surgeon.
A comparative study of additive and subtractive manufacturing for dental restorations.
Bae, Eun-Jeong; Jeong, Il-Do; Kim, Woong-Chul; Kim, Ji-Hwan
2017-08-01
Digital systems have recently found widespread application in the fabrication of dental restorations. For the clinical assessment of dental restorations fabricated digitally, it is necessary to evaluate their accuracy. However, studies of the accuracy of inlay restorations fabricated with additive manufacturing are lacking. The purpose of this in vitro study was to evaluate and compare the accuracy of inlay restorations fabricated by using recently introduced additive manufacturing with the accuracy of subtractive methods. The inlay (distal occlusal cavity) shape was fabricated using 3-dimensional image (reference data) software. Specimens were fabricated using 4 different methods (each n=10, total N=40), including 2 additive manufacturing methods, stereolithography apparatus and selective laser sintering; and 2 subtractive methods, wax and zirconia milling. Fabricated specimens were scanned using a dental scanner and then compared by overlapping reference data. The results were statistically analyzed using a 1-way analysis of variance (α=.05). Additionally, the surface morphology of 1 randomly (the first of each specimen) selected specimen from each group was evaluated using a digital microscope. The results of the overlap analysis of the dental restorations indicated that the root mean square (RMS) deviation observed in the restorations fabricated using the additive manufacturing methods were significantly different from those fabricated using the subtractive methods (P<.05). However, no significant differences were found between restorations fabricated using stereolithography apparatus and selective laser sintering, the additive manufacturing methods (P=.466). Similarly, no significant differences were found between wax and zirconia, the subtractive methods (P=.986). The observed RMS values were 106 μm for stereolithography apparatus, 113 μm for selective laser sintering, 116 μm for wax, and 119 μm for zirconia. Microscopic evaluation of the surface revealed a fine linear gap between the layers of restorations fabricated using stereolithography apparatus and a grooved hole with inconsistent weak scratches when fabricated using selective laser sintering. In the wax and zirconia restorations, possible traces of milling bur passes were observed. The results indicate that the accuracy of dental restorations fabricated using the additive manufacturing methods is higher than that of subtractive methods. Therefore, additive manufacturing methods are a viable alternative to subtractive methods. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Effect of various infection-control methods for light-cure units on the cure of composite resins.
Chong, S L; Lam, Y K; Lee, F K; Ramalingam, L; Yeo, A C; Lim, C C
1998-01-01
This study (1) compared the curing-light intensity with various barrier infection-control methods used to prevent cross contamination, (2) compared the Knoop hardness value of cured composite resin when various barrier control methods were used, and (3) correlated the hardness of the composite resin with the light-intensity output when different infection-control methods were used. The light-cure unit tips were covered with barriers, such as cellophane wrap, plastic gloves, Steri-shields, and finger cots. The control group had no barrier. Composite resins were then cured for each of the five groups, and their Knoop hardness values recorded. The results showed that there was significant statistical difference in the light-intensity output among the five groups. However, there was no significant statistical difference in the Knoop hardness values among any of the groups. There was also no correlation between the Knoop hardness value of the composite resin with the light-intensity output and the different infection-control methods. Therefore, any of the five infection-control methods could be used as barriers for preventing cross-contamination of the light-cure unit tip, for the light-intensity output for all five groups exceeded the recommended value of 300 W/m2. However, to allow a greater margin of error in clinical situations, the authors recommend that the plastic glove or the cellophane wrap be used to wrap the light-cure tip, since these barriers allowed the highest light-intensity output.
Adult Learners' Preferred Methods of Learning Preventative Heart Disease Care
ERIC Educational Resources Information Center
Alavi, Nasim
2016-01-01
The purpose of this study was to investigate the preferred method of learning about heart disease by adult learners. This research study also investigated if there was a statistically significant difference between race/ethnicity, age, and gender of adult learners and their preferred method of learning preventative heart disease care. This…
Tobin, R S; Lomax, P; Kushner, D J
1980-01-01
Nine different brands of membrane filter were compared in the membrane filtration (MF) method, and those with the highest yields were compared against the most-probable-number (MPN) multiple-tube method for total coliform enumeration in simulated sewage-contaminated tap water. The water was chlorinated for 30 min to subject the organisms to stresses similar to those encountered during treatment and distribution of drinking water. Significant differences were observed among membranes in four of the six experiments, with two- to four-times-higher recoveries between the membranes at each extreme of recovery. When results from the membranes with the highest total coliform recovery rate were compared with the MPN results, the MF results were found significantly higher in one experiment and equivalent to the MPN results in the other five experiments. A comparison was made of the species enumerated by these methods; in general the two methods enumerated a similar spectrum of organisms, with some indication that the MF method was subject to greater interference by Aeromonas. PMID:7469407
Sex differences in mechanical allodynia: how can it be preclinically quantified and analyzed?
Nicotra, Lauren; Tuke, Jonathan; Grace, Peter M.; Rolan, Paul E.; Hutchinson, Mark R.
2014-01-01
Translating promising preclinical drug discoveries to successful clinical trials remains a significant hurdle in pain research. Although animal models have significantly contributed to understanding chronic pain pathophysiology, the majority of research has focused on male rodents using testing procedures that produce sex difference data that do not align well with comparable clinical experiences. Additionally, the use of animal pain models presents ongoing ethical challenges demanding continuing refinement of preclinical methods. To this end, this study sought to test a quantitative allodynia assessment technique and associated statistical analysis in a modified graded nerve injury pain model with the aim to further examine sex differences in allodynia. Graded allodynia was established in male and female Sprague Dawley rats by altering the number of sutures placed around the sciatic nerve and quantified by the von Frey test. Linear mixed effects modeling regressed response on each fixed effect (sex, oestrus cycle, pain treatment). On comparison with other common von Frey assessment techniques, utilizing lower threshold filaments than those ordinarily tested, at 1 s intervals, appropriately and successfully investigated female mechanical allodynia, revealing significant sex and oestrus cycle difference across the graded allodynia that other common behavioral methods were unable to detect. Utilizing this different von Frey approach and graded allodynia model, a single suture inflicting less allodynia was sufficient to demonstrate exaggerated female mechanical allodynia throughout the phases of dioestrus and pro-oestrus. Refining the von Frey testing method, statistical analysis technique and the use of a graded model of chronic pain, allowed for examination of the influences on female mechanical nociception that other von Frey methods cannot provide. PMID:24592221
Gondim Teixeira, Pedro Augusto; Leplat, Christophe; Chen, Bailiang; De Verbizier, Jacques; Beaumont, Marine; Badr, Sammy; Cotten, Anne; Blum, Alain
2017-12-01
To evaluate intra-tumour and striated muscle T1 value heterogeneity and the influence of different methods of T1 estimation on the variability of quantitative perfusion parameters. Eighty-two patients with a histologically confirmed musculoskeletal tumour were prospectively included in this study and, with ethics committee approval, underwent contrast-enhanced MR perfusion and T1 mapping. T1 value variations in viable tumour areas and in normal-appearing striated muscle were assessed. In 20 cases, normal muscle perfusion parameters were calculated using three different methods: signal based and gadolinium concentration based on fixed and variable T1 values. Tumour and normal muscle T1 values were significantly different (p = 0.0008). T1 value heterogeneity was higher in tumours than in normal muscle (variation of 19.8% versus 13%). The T1 estimation method had a considerable influence on the variability of perfusion parameters. Fixed T1 values yielded higher coefficients of variation than variable T1 values (mean 109.6 ± 41.8% and 58.3 ± 14.1% respectively). Area under the curve was the least variable parameter (36%). T1 values in musculoskeletal tumours are significantly different and more heterogeneous than normal muscle. Patient-specific T1 estimation is needed for direct inter-patient comparison of perfusion parameters. • T1 value variation in musculoskeletal tumours is considerable. • T1 values in muscle and tumours are significantly different. • Patient-specific T1 estimation is needed for comparison of inter-patient perfusion parameters. • Technical variation is higher in permeability than semiquantitative perfusion parameters.
Park, Jun-Beom; Yang, Seung-Min; Ko, Youngkyung
2015-12-01
The purpose of this study was to evaluate the surface characteristics of various implant abutment materials, such as of titanium alloy (Ti6Al4V; Ma), machined cobalt-chrome-molybdenum alloy (CCM), titanium nitride coating on a titanium alloy disc (TiN), anodic oxidized titanium alloy disc (AO), composite resin coating on a titanium alloy disc (Res), and zirconia disc (Zr), using confocal microscopy and white light interferometry. Measurements from the 2 methods were evaluated to see if these methods would give equivalent results. The precision of measurements were evaluated by the coefficient of variation. Five discs each of Ma, CCM, TiN, AO, Res, and Zr were used. The surface roughness was evaluated by confocal laser microscopy and white light interferometry. Confocal microscopy showed that the Res group showed significantly greater Ra, Rq, Rz, Sa, Sq, and Sz values compared with those of the Ma group (P < 0.05). The white light interferometry results showed that the Res group had significantly higher Ra, Rq, Rz, Rt, Sa, Sq, Sz, and Sdr values compared with the Ma group (P < 0.05). All the roughness parameters obtained from the 2 methods differed, and the Sa values of the Zr group from confocal microscopy were greater by 0.163 μm than those obtained by white light interferometry. Least difference was seen in the TiN group where the difference was 0.058 μm. Roughness parameters of different abutment materials varied significantly. Precision of measurement differed according to the characteristics of the material used. White light interferometry could be recommended for measurement of TiN and AO. Confocal microscopy gave more precise measurements for Ma and CCM groups. The optical characteristics of the surface should be considered before choosing the examination method.
Yan-hua, Chen; Fang, Lian; Shi, Na
2011-12-01
To study the clinical effects of Shen-nourishing and menstruation-regulating method (SNMRM) combined with Triptorelin Acetate Injection (TAI) on patients with luteinized unruptured follicle syndrome (LUFS). Sixty-two LUFS patients were randomly assigned to the treatment group and the control group. TAI was given to patients in the control group while SNMRM + TAI was given to those in the treatment group. The ovulation rate and the pregnancy rate were observed in the two groups. The ovulation rate in the treatment group was higher than that in the control group, but without significant difference (85.53% versus 79.07%, P > 0.05). The pregnancy rate was significantly higher in the treatment group than in the control group (56.25% vs 30.00%, P < 0.05). Treatment of LUFS by SNMRM + TAI could improve the ovulation rate and the pregnancy rate, indicating that LUFS patients' ovary functions could be improved by using different menstruation regulating methods during different follicular development phases.
Eras, Jordi; Oró, Robert; Torres, Mercè; Canela, Ramon
2008-07-09
The stability of the cyclopropane ring and the fatty acid composition of microbial cells were determined using chlorotrimethylsilane as reagent with three different conditions 80 degrees C for 1 h, 60 degrees C for 1 h, and 60 degrees C for 2 h. Chlorotrimethylsilane permits a simultaneous extraction and derivatization of fatty acids. A basic method was used as reference. The bacteria, Escherichia coli, Burkholderia cepacia, and Lactobacillus brevis, and fungi Aspergillus niger and Gibberella fujikuroi were used. The stability of the cyclopropane ring on acidic conditions was tested using the cyclopropanecarboxylic acid and a commercial mixture of bacteria fatty acid methyl esters (BAME). Fisher's least significant difference test showed significant differences among the methods. The method using chlorotrimethylsilane and 1-pentanol for 1 h at 80 degrees C gave the best results in cyclopropane, hydroxyl, and total fatty acid recoveries. This procedure allows the fast and easy one-step direct extraction derivatization.
Prinz, I; Nubel, K; Gross, M
2002-09-01
Until now, the assumed benefits of digital hearing aids are reflected only in subjective descriptions by patients with hearing aids, but cannot be documented adequately by routine diagnostic methods. Seventeen schoolchildren with moderate severe bilateral symmetrical sensorineural hearing loss were examined in a double-blinded crossover study. Differences in performance between a fully digital hearing aid (DigiFocus compact/Oticon) and an analogous digitally programmable two-channel hearing aid were evaluated. Of the 17 children, 13 choose the digital and 4 the analogous hearing aid. In contrast to the clear subjective preferences for the fully digital hearing aid, we could not obtain any significant results with routine diagnostic methods. Using the "virtual hearing aid," a subjective comparison and speech recognition performance task yielded significant differences. The virtual hearing aid proved to be suitable for a direct comparison of different hearing aids and can be used for double-blind testing in a pediatric population.
Appraisal of different ultrasonography indices in patients with carotid artery atherosclerosis
Rafati, Mehravar; Havaee, Elham; Moladoust, Hassan; Sehhati, Mohammadreza
2017-01-01
In this study a semi-automated image-processing based method was designed in which the parameters such as intima-media thickness (IMT), resistive index (RI), pulsatility index (PI), dicrotic notch index (DNI), and mean wavelet entropy (MWE) were evaluated in B-mode and Doppler ultrasound in patients presenting with carotid artery atherosclerosis. In a cross-sectional design, 144 men were divided into four groups of control, mild, moderate and severe stenosis subjects. In all individuals, far wall IMT, RI, PI, DNI, and MWE of the left common carotid artery (CCA) were extracted using the proposed method. Our findings showed that the maximum far wall IMT, RI, PI, DNI in the CCA were significantly different in the patients with mild, moderate, and severe stenosis compared to control group (p-value < 0.05), however, there were no significant differences in MWE among the four groups (p-value > 0.05). The proposed method can help physicians to better identify patients at risk of cardiovascular diseases. PMID:28827988
Noh, Ji-Woong; Kim, Mee-Young; Lee, Lim-Kyu; Park, Byoung-Sun; Yang, Seung-Min; Jeon, Hye-Joo; Lee, Won-Deok; Kim, Ju-Hyun; Lee, Jeong-Uk; Kwak, Taek-Yong; Lee, Tae-Hyun; Kim, Ju-Young; Kim, Junghwan
2015-01-01
[Purpose] The purpose of this study was to investigate the somatotype and physical characteristic differences among elite youth soccer players. [Subjects and Methods] In the present study, we evaluated twenty-two Korean youth soccer players in different playing positions. The playing positions were divided into forward (FW), midfielder (MF), defender (DF), and goalkeeper (GK). The participants’ lean body mass (LBM), fat free mass (FFM), fat mass (FM), and basal metabolic rate (BMR) were measured and their somatotype determined according to the Heath-Carter method. [Results] The youth soccer players had twelve ectomorphic, eight mesomorphic, and two central predominant types. The DFs were taller than, but otherwise similar in physical characteristics to the FWs and MFs. The GKs were taller and heavier than the other players; however, their somatotype components were not significantly different. LBM, FFM, and BMR were significantly higher in GKs than in FWs and MFs. Although LBM, FFM, and BMR values between GKs and DFs showed large differences, they were not statistically significant. [Conclusion] The present study may contribute to our understanding of the differences in somatotype and body composition of Korean youth soccer players involved in sports physiotherapy research. PMID:25995545
Noh, Ji-Woong; Kim, Mee-Young; Lee, Lim-Kyu; Park, Byoung-Sun; Yang, Seung-Min; Jeon, Hye-Joo; Lee, Won-Deok; Kim, Ju-Hyun; Lee, Jeong-Uk; Kwak, Taek-Yong; Lee, Tae-Hyun; Kim, Ju-Young; Kim, Junghwan
2015-04-01
[Purpose] The purpose of this study was to investigate the somatotype and physical characteristic differences among elite youth soccer players. [Subjects and Methods] In the present study, we evaluated twenty-two Korean youth soccer players in different playing positions. The playing positions were divided into forward (FW), midfielder (MF), defender (DF), and goalkeeper (GK). The participants' lean body mass (LBM), fat free mass (FFM), fat mass (FM), and basal metabolic rate (BMR) were measured and their somatotype determined according to the Heath-Carter method. [Results] The youth soccer players had twelve ectomorphic, eight mesomorphic, and two central predominant types. The DFs were taller than, but otherwise similar in physical characteristics to the FWs and MFs. The GKs were taller and heavier than the other players; however, their somatotype components were not significantly different. LBM, FFM, and BMR were significantly higher in GKs than in FWs and MFs. Although LBM, FFM, and BMR values between GKs and DFs showed large differences, they were not statistically significant. [Conclusion] The present study may contribute to our understanding of the differences in somatotype and body composition of Korean youth soccer players involved in sports physiotherapy research.
[Arginase Level in Suspended Red Blood Cells Storaged for Different Time].
Fan, Li-Ping; Huang, Hao-Bo; Wei, Shi-Jin; Fu, Dan-Hui; Zeng, Feng; Huang, Qing-Hua; Hong, Jin-Quan
2015-10-01
To explore the effect of storage time on arginase level, and the possible source of arginase in suspended red blood cells (RBC). The arginase and myeloperoxidase (MPO) levels in suspended RBC and control plasma were detected by ELISA. The free hemoglobin level in suspended RBC and control plasma were detected by colorimetric method. The relationship between arginase level, MPO level and free hemoglobin level in suspended RBC was analyzed by the related methods. The arginase and free hemoglobin levels in suspended RBC were higher than those in control plasma. Otherwise, MPO level was not significantly different between suspended RBC and control plasma. All of them did not increase along with prolonging of storage time. There was not a significant correlation between arginase level and free hemoglobin level in suspended RBC of different storage time (r = 0.03), but arginase level positively correlated with MPO level in the suspended RBC of different storage time (r = 0.76). The arginase level in suspended RBC storaged for different time increases significantly, but not along with prolonging of storage time. The main possible source of arginase in the suspended RBC is the residual white blood cell, especially neutrophils.
Elgohary, Hany M; Tantawy, Sayed A
2017-01-01
[Purpose] To investigate the effect of pulsed electromagnetic field with or without exercise therapy in the treatment of benign prostatic hyperplasia. [Subjects and Methods] Sixty male patients aged 55–65 years with benign prostatic hyperplasia were invited to participate in this study. Patients were randomly assigned to Group A (n=20; patients who received pulsed electromagnetic field in addition to pelvic floor and aerobic exercises), Group B (n=20; patients who received pulsed electromagnetic field), and Group C (n=20; patients who received placebo electromagnetic field). The assessments included post-void residual urine, urine flow rate, prostate specific antigen, white blood cells count, and International Prostate Symptom Score were weighed, before and after a 4-week intervention. [Results] There were significant differences in Group A and B in all parameters. Group C showed non-significant differences in all measured variables except for International Prostate Symptom Score. Among groups, all parameters showed highly significant differences in favor of Group A. There were non-significant differences between Group A and B and significant difference between Groups A and C and between Groups B and C. [Conclusion] The present study demonstrated that electromagnetic field had a significant impact on the treatment of benign prostatic hyperplasia. Accordingly, electromagnetic field can be utilized alone or in combination with other physiotherapy modalities. Moreover, clinicians should have the capacity to perceive the advantages accomplished using extra treatment alternatives. Electromagnetic field is a safe, noninvasive method and can be used for the treatment of benign prostatic hyperplasia. PMID:28878453
Improved image alignment method in application to X-ray images and biological images.
Wang, Ching-Wei; Chen, Hsiang-Chou
2013-08-01
Alignment of medical images is a vital component of a large number of applications throughout the clinical track of events; not only within clinical diagnostic settings, but prominently so in the area of planning, consummation and evaluation of surgical and radiotherapeutical procedures. However, image registration of medical images is challenging because of variations on data appearance, imaging artifacts and complex data deformation problems. Hence, the aim of this study is to develop a robust image alignment method for medical images. An improved image registration method is proposed, and the method is evaluated with two types of medical data, including biological microscopic tissue images and dental X-ray images and compared with five state-of-the-art image registration techniques. The experimental results show that the presented method consistently performs well on both types of medical images, achieving 88.44 and 88.93% averaged registration accuracies for biological tissue images and X-ray images, respectively, and outperforms the benchmark methods. Based on the Tukey's honestly significant difference test and Fisher's least square difference test tests, the presented method performs significantly better than all existing methods (P ≤ 0.001) for tissue image alignment, and for the X-ray image registration, the proposed method performs significantly better than the two benchmark b-spline approaches (P < 0.001). The software implementation of the presented method and the data used in this study are made publicly available for scientific communities to use (http://www-o.ntust.edu.tw/∼cweiwang/ImprovedImageRegistration/). cweiwang@mail.ntust.edu.tw.
Jannink, I; Bennen, J N; Blaauw, J; van Diest, P J; Baak, J P
1995-01-01
This study compares the influence of two different nuclear sampling methods on the prognostic value of assessments of mean and standard deviation of nuclear area (MNA, SDNA) in 191 consecutive invasive breast cancer patients with long term follow up. The first sampling method used was 'at convenience' sampling (ACS); the second, systematic random sampling (SRS). Both sampling methods were tested with a sample size of 50 nuclei (ACS-50 and SRS-50). To determine whether, besides the sampling methods, sample size had impact on prognostic value as well, the SRS method was also tested using a sample size of 100 nuclei (SRS-100). SDNA values were systematically lower for ACS, obviously due to (unconsciously) not including small and large nuclei. Testing prognostic value of a series of cut off points, MNA and SDNA values assessed by the SRS method were prognostically significantly stronger than the values obtained by the ACS method. This was confirmed in Cox regression analysis. For the MNA, the Mantel-Cox p-values from SRS-50 and SRS-100 measurements were not significantly different. However, for the SDNA, SRS-100 yielded significantly lower p-values than SRS-50. In conclusion, compared with the 'at convenience' nuclear sampling method, systematic random sampling of nuclei is not only superior with respect to reproducibility of results, but also provides a better prognostic value in patients with invasive breast cancer.
Khare, Anshul Kumar; Abraham, Robinson J J; Appa Rao, V; Babu, R Narendra
2016-02-01
The present study was conducted to determine efficacy of edible coating of carrageenan and cinnamon oil to enhance the shelf life of chicken meat stored under refrigeration conditions. Chicken breast was coated with carrageenan and cinnamon oil by three methods of application viz., spraying brushing and dipping. The coated meat was evaluated for drip loss, pH, thiobarbituric acid number (TBA), tyrosine value (TV), extract release volume (ERV), Warner-Bratzler shear force value (WBSFV), instrumental color, microbiological, and sensory qualities as per standard procedures. There was a significant difference observed for physicochemical parameters (pH, TBA, TV, ERV, drip loss and WBSFV) and microbiological analysis between storage periods in all the samples and between the control and treatments throughout the storage period but samples did not differed significantly for hunter color scores. However, there was no significant difference among three methods of application throughout the storage period though dipping had a lower rate of increase. A progressive decline in mean sensory scores was recorded along with the increase in storage time. The carrageenan and cinnamon edible coating was found to be a good alternative to enhance the shelf life of chicken meat under refrigeration conditions. It was also observed from study that dipping method of the application had comparatively higher shelf life than other methods of application.
Unger, Stefan; Stefan, Unger; Blauth, Michael; Michael, Blauth; Schmoelz, Werner; Werner, Schmoelz
2010-12-01
In the development of new strategies for fracture fixation, new methods have to be tested biomechanically under in vitro conditions before clinical trials can be performed. The gold standard for laboratory evaluations is fresh-frozen specimen. As the availability of fresh-frozen specimens is limited and since their use bears infectious risks, specimens treated with various chemical embalming fluids are also used. These preservation methods may alter the mechanical properties of the specimens used. Therefore, the aims of the present study were to determine the effects of three different preservation methods (formalin fixation (FO), Thiel-fixation (TH), and alcohol-glycerine fixation (AG)) on the elastic and postyield mechanical properties of cortical bone and to compare these properties to those of fresh-frozen (FF) specimens. Cylindrical cortical specimens (diameter 3mm, length 60 mm) were obtained from human femurs (n=48) and bovine tibiae (n=40). Before specimen immersion in different fixation fluids, bone mineral density (BMD) as well as the initial Young's modulus was determined. The Young's modulus was determined in a nondestructive bending test, and measurements were repeated after 6 months of immersion in fixative solution. Subsequent to the nondestructive test, a destructive 3-point bending test was conducted to assess the postyield and fracture properties. The BMD as well as the initial Young's modulus showed no significant differences between the four test groups. After 6 months in fixative solution, the Young's modulus was significantly lowered in human Thiel specimens and only showed minor changes in formalin- and alcohol-glycerine-treated specimens. The plastic energy absorption of human and bovine specimens was altered significantly. Formalin as well as alcohol-glycerine fixation yielded a significant decrease in plastic energy absorption, whereas Thiel fixation significantly increased the plastic energy absorption. Because of the significantly altered plastic mechanical properties of cortical bone, the use fresh-frozen bone specimens is recommended in biomechanical studies investigating failure loads of orthopaedic implants. The use of embalmed specimens should be restricted to pilot tests. Copyright © 2010 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Gogu, C.; Haftka, R.; LeRiche, R.; Molimard, J.; Vautrin, A.; Sankar, B.
2008-11-01
The basic formulation of the least squares method, based on the L2 norm of the misfit, is still widely used today for identifying elastic material properties from experimental data. An alternative statistical approach is the Bayesian method. We seek here situations with significant difference between the material properties found by the two methods. For a simple three bar truss example we illustrate three such situations in which the Bayesian approach leads to more accurate results: different magnitude of the measurements, different uncertainty in the measurements and correlation among measurements. When all three effects add up, the Bayesian approach can have a large advantage. We then compared the two methods for identification of elastic constants from plate vibration natural frequencies.
Neuner-Jehle, S; Wegwarth, O; Steurer, J
2008-06-11
Communication about risk, e.g. cardiovascular risk, is a central task of physicians in their daily practice. In this paper we summarize the different methods of risk communication published in the literature. The different methods and their particular advantages and shortcomings are described and some recommendations are formulated. The most significant of them are: verbal qualifiers like, your risk for a cardiovascular event is moderate, is imprecise and difficult to interpret. Information about risk in numerical form is more comprehensible when delivered in natural frequencies compared to percentages, pictorial representations contribute to a better understanding. Probably not one single mode of representation is the most effective way to convey information about risk, but a combination of methods.
Effect of E-learning on primigravida women's satisfaction and awareness concerning prenatal care
Mohamadirizi, Soheila; Bahadoran, Parvin; Fahami, Fariba
2014-01-01
Background: E-learning, in addition to promotion of patients’ level of awareness, causes a more efficient way to increase patient-personnel interaction and provision of patients’ educational content. Materials and Methods: In a quasi-experimental study, 100 primigravida women, referring to Navab Safavi health care center affiliated to Isfahan University of Medical Sciences, were selected through convenient sampling. The subjects received education via E-learning or booklet education methods for four weeks. Questionnaire of satisfaction with the awareness of prenatal care was completed by both groups before and 4-6 weeks after education. Data were analyzed by student t-test and paired t-test through SPSS with a significance level of P < 0.05. Results: No significant difference was noted between scores of satisfaction and awareness in both groups before education, while a significant difference was observed four weeks after intervention (P = 0.004). There was a significant difference between scores of satisfaction and awareness after intervention in both groups (P = 0.001, P = 0.034). Satisfaction and awareness scores increased by 169% and 123%, and 61% and 37% in the E-learning and control groups, respectively (P = 0.034). Conclusions: E-learning can cause an increase in the level of primigravida women's satisfaction and awareness. Therefore, conducting such education, as an efficient learning method, is recommended as it needs less time, has lower costs, and does not need any special equipment. PMID:24741653
Tian, Yu; Guan, Bo; Zhou, Daowei; Yu, Junbao; Li, Guangdi; Lou, Yujie
2014-01-01
A series of seed priming experiments were conducted to test the effects of different pretreatment methods to seed germination, seedling growth, and seed yield traits in maize (Zea mays L.). Results indicated that the seeds primed by gibberellins (GA), NaCl, and polyethylene glycol (PEG) reagents showed a higher imbibitions rate compared to those primed with water. The final germination percentage and germination rate varied with different reagents significantly (P < 0.05). The recommended prime reagents were GA at 10 mg/L, NaCl at 50 mM, and PEG at 15% on account of germination experiment. 15% PEG priming reagent increased shoot and root biomass of maize seedling. The shoot biomass of seedlings after presoaking the seeds with NaCl reagent was significantly higher than the seedlings without priming treatment. No significant differences of plant height, leaf number, and hundred-grain weight were observed between control group and priming treatments. Presoaking with water, NaCl (50 mM), or PEG (15%) significantly increased the hundred-grain weight of maize. Therefore, seed pretreatment is proved to be an effective technique to improve the germination performance, seedling growth, and seed yield of maize. However, when compared with the two methods, if immediate sowing is possible, presoaking is recommended to harvest better benefits compared to priming method.
Biaggi, R R; Vollman, M W; Nies, M A; Brener, C E; Flakoll, P J; Levenhagen, D K; Sun, M; Karabulut, Z; Chen, K Y
1999-05-01
Over the past decade, considerable attention has been paid to accurately measuring body composition in diverse populations. Recently, the use of air-displacement plethysmography (AP) was proposed as an accurate, comfortable, and accessible method of body-composition analysis. The purpose of this study was to compare measurements of percentage body fat (%BF) by AP and 2 other established techniques, hydrostatic weighing (HW) and bioelectrical impedance analysis (BIA), in adults. The sample consisted of healthy men (n = 23) and women (n = 24). %BF was measured by AP, HW, and BIA. In the total group, %BF(AP) (25.0+/-8.9%) was not significantly different from %BF(HW) (25.1+/-7.7%) or %BF(BIA) (23.9+/-7.7%), and %BF(AP) was significantly correlated with %BF(HW) (r = 0.944, P < 0.001) and with %BF(BIA) (r = 0.859, P < 0.01). Compared with HW, AP underestimated %BF in men (by -1.24+/-3.12%) but overestimated %BF in women (by 1.02+/-2.48%), indicating a significant sex effect (P < 0.05). The differences in estimation between AP and BIA and between BIA and HW were not significantly different between the sexes. AP is an accurate method for assessing body composition in healthy adults. Future studies should assess further the cause of the individual variations with this new method.
Best practices for learning physiology: combining classroom and online methods.
Anderson, Lisa C; Krichbaum, Kathleen E
2017-09-01
Physiology is a requisite course for many professional allied health programs and is a foundational science for learning pathophysiology, health assessment, and pharmacology. Given the demand for online learning in the health sciences, it is important to evaluate the efficacy of online and in-class teaching methods, especially as they are combined to form hybrid courses. The purpose of this study was to compare two hybrid physiology sections in which one section was offered mostly in-class (85% in-class), and the other section was offered mostly online (85% online). The two sections in 2 yr ( year 1 and year 2 ) were compared in terms of knowledge of physiology measured in exam scores and pretest-posttest improvement, and in measures of student satisfaction with teaching. In year 1 , there were some differences on individual exam scores between the two sections, but no significant differences in mean exam scores or in pretest-posttest improvements. However, in terms of student satisfaction, the mostly in-class students in year 1 rated the instructor significantly higher than did the mostly online students. Comparisons between in-class and online students in the year 2 cohort yielded data that showed that mean exam scores were not statistically different, but pre-post changes were significantly greater in the mostly online section; student satisfaction among mostly online students also improved significantly. Education researchers must investigate effective combinations of in-class and online methods for student learning outcomes, while maintaining the flexibility and convenience that online methods provide. Copyright © 2017 the American Physiological Society.
Evaluation of ultrasound in assessing body composition of high school wrestlers.
Utter, Alan C; Hager, Marion E
2008-05-01
To evaluate the accuracy of ultrasound (ULTRA) in assessing fat-free mass (FFM) in comparison with hydrostatic weighing (HW) and skinfolds (SK) in high school wrestlers in a hydrated state. Body composition was determined by ULTRA, HW, and three-site SK in 70 high school wrestlers (mean +/- SD: age, 15.5 +/- 1.5; height, 1.60 +/- 0.08 m; body mass, 65.8 +/- 12.7 kg). For all methods, body density (Db) was converted to percent body fat (%BF) using the Brozek equation. Hydration state was quantified by evaluating urine specific gravity. There were no significant differences for estimated FFM between ULTRA (57.2 +/- 9.7 kg) and HW (57.0 +/- 9.9 kg); however, SK (54.9 +/- 8.8 kg) were significantly different from HW. The standard errors of estimate for FFM with HW as the reference method were 2.40 kg for ULTRA and 2.74 kg for SK. Significant correlations were found for FFM between HW and ULTRA (r = 0.97, P < 0.001) and between HW and SK (r = 0.96, P < 0.001). A systematic bias was found for SK, as the difference between SK and HW significantly correlated with the FFM average of the two methods (r = -0.38, P < 0.001). This systematic bias was not found for ULTRA (r = - 0.07). This study demonstrates that ULTRA provides similar estimates of FFM when compared with HW in a heterogeneous high school wrestling population during a hydrated state. ULTRA should be considered as an alternative field-based method of estimating the FFM of high school wrestlers.
Seasonality and synchrony of reproduction in three species of nectarivorous Philippines bats.
Heideman, Paul D; Utzurrum, Ruth C B
2003-11-21
Differences among species and among years in reproductive seasonality (the tendency for clusters of events to fall at approximately the same point in each year) and synchrony (amount of clustering of events within a year) have been intensively studied in bats, but are difficult to assess. Here, we use randomization methods with circular statistics to test for synchrony and seasonality of reproduction in three species of nectarivorous megachiropteran bats on Negros Island in the central Philippines. In Rousettus amplexicaudatus, estimated dates of birth were both highly synchronous and highly seasonal. In Macroglossus minimus, estimated births were seasonal and significantly clustered within years, but within each year births occurred over a broad period, indicating a low level of synchrony. In Eonycteris spelaea, estimated births were also seasonal and had statistically significant synchrony, with birth periods within years intermediate in synchrony between R. amplexicaudatus and M. minimus. All three species had a similar seasonal pattern, with two birth periods in each year, centered on March or April and August or September. In one species, R. amplexicaudatus, primigravid females (in their first pregnancy) produced their young in June and July, a birth period significantly different in timing from the two birth periods of older adult females. This more conservative pattern of young females may allow higher survival of parents and offspring at cost of a lost reproductive opportunity. There was weak evidence that in some years primigravid females of M. minimus might differ in timing from older adults. There were few significant differences in reproductive timing among different years, and those differences were generally less than two weeks, even during a severe drought in the severe el Niño of 1983. The results suggest that these species follow an obligately seasonal pattern of reproductive timing with very little phenotypic plasticity. The resampling methods were sensitive to differences in timing of under two weeks, in some cases, suggesting that these are useful methods for analyses of seasonality in wild populations of bats.
SAVAS, Selcuk; KAVRÌK, Fevzi; KUCUKYÌLMAZ, Ebru
2016-01-01
ABSTRACT Objective The aim of this study was to evaluate the efficacy of CPP-ACP containing fluoride varnish for remineralizing white spot lesions (WSLs) with four different quantitative methods. Material and Methods Four windows (3x3 mm) were created on the enamel surfaces of bovine incisor teeth. A control window was covered with nail varnish, and WSLs were created on the other windows (after demineralization, first week and fourth week) in acidified gel system. The test material (MI Varnish) was applied on the demineralized areas, and the treated enamel samples were stored in artificial saliva. At the fourth week, the enamel surfaces were tested by surface microhardness (SMH), quantitative light-induced fluorescence-digital (QLF-D), energy-dispersive spectroscopy (EDS) and laser fluorescence (LF pen). The data were statistically analyzed (α=0.05). Results While the LF pen measurements showed significant differences at baseline, after demineralization, and after the one-week remineralization period (p<0.05), the difference between the 1- and 4-week was not significant (p>0.05). With regards to the SMH and QLF-D analyses, statistically significant differences were found among all the phases (p<0.05). After the 1- and 4-week treatment periods, the calcium (Ca) and phosphate (P) concentrations and Ca/P ratio were higher compared to those of the demineralization surfaces (p<0.05). Conclusion CPP-ACP containing fluoride varnish provides remineralization of WSLs after a single application and seems suitable for clinical use. PMID:27383699
Perforated peptic ulcer in southeastern Taiwan.
Li, Chin-Hsien; Chang, Wen-Hsiung; Shih, Shou-Chuan; Lin, Shee-Chan; Bair, Ming-Jong
2010-09-01
No studies focus on the population with perforated peptic ulcer in southeastern Taiwan. The present study aimed to assess the differences between the different races and the risk factors related to mortality and morbidity in postoperative patients in southeastern Taiwan. The medical records of 237 patients were reviewed retrospectively. The following factors were analyzed: patient profiles, coexisting illnesses, diagnostic method, fever, preoperative shock, clinical data at emergency room, delay operation, site of perforation, operative method, positive ascites culture, species of microbes in ascites culture, postoperative complications, death and the length of hospital stay. Aborigines were significantly different from non-aborigines in the ratio of female cases and in the habits of alcohol drinking and betel nut chewing. There were also four significantly different variables between them: fever, hemoglobin value, site of perforation and operative method. Total postoperative complication rate was 41.3% and 39 patients (16.6%) died. In multivariate analysis, age > or = 65 years, lipase > upper normal limit and preoperative shock were independent predictors of mortality. Significant risk factors associated with morbidity were NSAIDs use, creatinine > 1.5 mg/dL and preoperative shock. Aborigines were different from non-aborigines in several categories. In southeastern Taiwan, NSAIDs use, creatinine > 1.5 mg/dL and preoperative shock were independent risk factors of morbidity, and age > or = 65 years, lipase > upper normal limit and preoperative shock were independent risk factors of mortality in postoperative perforated peptic ulcer. Lipase > upper normal limit is needed for further research on the influence on mortality.
Demirel, Gamze; Uras, Nurdan; Celik, Istemi H; Aksoy, Hatice T; Oguz, Serife S; Erdeve, Omer; Erel, Ozcan; Dilmen, Ugur
2010-10-01
We evaluated and compared the oxidant and antioxidant status of hyperbilirubinemic infants before and after the two forms of phototherapy: conventional and LED phototherapy, in order to identify the optimal treatment method. Thirty newborns exposed to conventional (Group I) phototherapy and 30 infants exposed to LED phototherapy (Group II) were studied. The serum total antioxidant capacity (TAC) and the total oxidant status (TOS) were assessed by EREL's method. There were no statistically significant differences in TAC or TOS levels between Group I and Group II prior to phototherapy, and no statistically significant difference in TAC levels between the two groups after phototherapy; however, TOS levels were significantly lower in Group II compared to Group I after phototherapy. Oxidative stress index (OSI) increased after conventional phototherapy (p < 0.05) The increase in TOS following conventional phototherapy was not not observed following LED phototherapy. This difference should be considered when using phototherapy.
2010-01-01
Introduction Sterilization and re-usage of tumour bone for reconstruction after tumour resection is now gaining popularity in the East. This recycle tumour bone needs to be sterilized in order to eradicate the tumour cells before re-implantation for limb salvage procedures. The effect of some of these treatments on the integrity and sterility of the bone after treatment has been published but there has yet been a direct comparison between the various methods of sterilization to determine the one method that gives the best tumour kill without compromising the bone's structural integrity. Method This study was performed to evaluate the effect of several sterilization methods on the mechanical behavior of human cortical bone graft and histopathology evaluation of tumour bone samples after being processed with 4 different methods of sterilization. Fresh human cortical tumour bone is harvested from the diaphyseal region of the tumour bone were sterilized by autoclave (n =10); boiling (n =10); pasteurization (n =10); and irradiation (n =10). There were also 10 control specimens that did not receive any form of sterilization treatment. The biomechanical test conducted were stress to failure, modulus and strain to failure, which were determined from axial compression testing. Statistical analysis (ANOVA) was performed on these results. Significance level (α) and power (β) were set to 0.05 and 0.90, respectively. Results ANOVA analysis of 'failure stress', 'modulus' and 'strain to failure' demonstrated significant differences (p < 0.05) between treated cortical bone and untreated specimens under mechanical loading. 'Stress to failure' was significantly reduced in boiled, autoclaved and irradiated cortical bone samples (p < 0.05). 'Modulus' detected significant differences in the boiled, autoclaved and pasteurization specimens compared to controls (p < 0.05). 'Strain to failure' was reduced by irradiation (p < 0.05) but not by the other three methods of treatments. Histopathology study revealed no viable tumour cell in any of four types of treatment group compared to the untreated control group. Conclusions Sterilization of cortical bone sample by pasteurization and to a lesser extent, irradiation does not significantly alter the mechanical properties when compared with untreated samples. Mechanical properties degrade with the use of high temperature for sterilization (boiling). All methods of sterilization gave rise to 100 percent tumour kill. PMID:20831801
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhen, X; Chen, H; Liao, Y
Purpose: To study the feasibility of employing deformable registration methods for accurate rectum dose volume parameters calculation and their potentials in revealing rectum dose-toxicity between complication and non-complication cervical cancer patients with brachytherapy treatment. Method and Materials: Data from 60 patients treated with BT including planning images, treatment plans, and follow-up clinical exam were retrospectively collected. Among them, 12 patients complained about hematochezia were further examined with colonoscopy and scored as Grade 1–3 complication (CP). Meanwhile, another 12 non-complication (NCP) patients were selected as a reference group. To seek for potential gains in rectum toxicity prediction when fractional anatomical deformationsmore » are account for, the rectum dose volume parameters D0.1/1/2cc of the selected patients were retrospectively computed by three different approaches: the simple “worstcase scenario” (WS) addition method, an intensity-based deformable image registration (DIR) algorithm-Demons, and a more accurate, recent developed local topology preserved non-rigid point matching algorithm (TOP). Statistical significance of the differences between rectum doses of the CP group and the NCP group were tested by a two-tailed t-test and results were considered to be statistically significant if p < 0.05. Results: For the D0.1cc, no statistical differences are found between the CP and NCP group in all three methods. For the D1cc, dose difference is not detected by the WS method, however, statistical differences between the two groups are observed by both Demons and TOP, and more evident in TOP. For the D2cc, the CP and NCP cases are statistically significance of the difference for all three methods but more pronounced with TOP. Conclusion: In this study, we calculated the rectum D0.1/1/2cc by simple WS addition and two DIR methods and seek for gains in rectum toxicity prediction. The results favor the claim that accurate dose deformation and summation tend to be more sensitive in unveiling the dose-toxicity relationship. This work is supported in part by grant from VARIAN MEDICAL SYSTEMS INC, the National Natural Science Foundation of China (no 81428019 and no 81301940), the Guangdong Natural Science Foundation (2015A030313302)and the 2015 Pearl River S&T Nova Program of Guangzhou (201506010096).« less
2014-01-01
Background Currently, the metatarsophalangeal angle (hallux valgus angle) is measured based on radiographic images. However, using X-ray examinations for epidemiological or screening purposes would be unethical, especially in children. For this reason it is discussed to measure the hallux valgus angle of the margo medialis pedis (medial border of the foot) documented on foot outline drawings or foot scans. As a first step on the way to prove the validity of those approaches this study assesses the hallux valgus angle measured on the margo medialis pedis based on the same x-ray pictures as the metatarsophalangeal hallux valgus. Methods Radiographic images of the foot were obtained from patients with symptomatic hallux valgus malformation. Twelve sets of contact copies of the 63 originals were made, and were marked and measured according to three different methods, each one performed by two observers and with two repeated measurements. Thus, data sets from 756 individual assessments were entered into the multifactorial statistical analysis. Comparisons were made between the angle of the margo medialis pedis and the metatarsophalangeal angle, which was determined by two different methods. To determine the inter- and intraobserver reliability of the different methods, each assessment was conducted by two independent experts and repeated after a period of several weeks. Results The correlations between the hallux valgus angles determined by the three different methods were all above r = 0.89 (p < 0.001) and thus highly significant. The values obtained by measuring the margo medialis pedis angle, however, were on average 4.8 degrees smaller than the metatarsophalangeal angles. No significant differences were found between the observers. No systematic deviations for any observer between repeated measurements were detected. Conclusions Measurements of the radiographic hallux angle of the margo medialis pedis are reliable and show high correlation with the metatarsophalangeal angle. Because the hallux valgus angles based on margo medialis pedis measurements were slightly but statistically significantly smaller, these measurements should be considered conservative estimates of the metatarsophalangeal angle. Significant differences between hallux valgus angles based on radiographic and non-radiographic material are unlikely. However this question has to be treated in a second stage in detail. PMID:24751201
A three phase optimization method for precopy based VM live migration.
Sharma, Sangeeta; Chawla, Meenu
2016-01-01
Virtual machine live migration is a method of moving virtual machine across hosts within a virtualized datacenter. It provides significant benefits for administrator to manage datacenter efficiently. It reduces service interruption by transferring the virtual machine without stopping at source. Transfer of large number of virtual machine memory pages results in long migration time as well as downtime, which also affects the overall system performance. This situation becomes unbearable when migration takes place over slower network or a long distance migration within a cloud. In this paper, precopy based virtual machine live migration method is thoroughly analyzed to trace out the issues responsible for its performance drops. In order to address these issues, this paper proposes three phase optimization (TPO) method. It works in three phases as follows: (i) reduce the transfer of memory pages in first phase, (ii) reduce the transfer of duplicate pages by classifying frequently and non-frequently updated pages, and (iii) reduce the data sent in last iteration of migration by applying the simple RLE compression technique. As a result, each phase significantly reduces total pages transferred, total migration time and downtime respectively. The proposed TPO method is evaluated using different representative workloads on a Xen virtualized environment. Experimental results show that TPO method reduces total pages transferred by 71 %, total migration time by 70 %, downtime by 3 % for higher workload, and it does not impose significant overhead as compared to traditional precopy method. Comparison of TPO method with other methods is also done for supporting and showing its effectiveness. TPO method and precopy methods are also tested at different number of iterations. The TPO method gives better performance even with less number of iterations.
Surface modification for bonding between amalgam and orthodontic brackets.
Wongsamut, Wittawat; Satrawaha, Sirichom; Wayakanon, Kornchanok
2017-01-01
Testing of methods to enhance the shear bond strength (SBS) between orthodontic metal brackets and amalgam by sandblasting and different primers. Three hundred samples of amalgam restorations (KerrAlloy ® ) were prepared in self-cured acrylic blocks, polished, and divided into two groups: nonsandblasted and sandblasted. Each group was divided into five subgroups with different primers used in surface treatment methods, with a control group of bonded brackets on human mandibular incisors. Following the surface treatments, mandibular incisor brackets (Unitek ® ) were bonded on the amalgam with adhesive resin (Transbond XT ® ). The SBS of the samples was tested. The adhesive remnant index (ARI) and failure modes were then determined under a stereo-microscope. Two-way analysis of variance, Chi-square, and Kruskal-Wallis tests were performed to calculate the correlations between and among the SBS and ARI values, the failure modes, and surface roughness results. There were statistically significant differences of SBS among the different adhesive primers and sandblasting methods ( P < 0.05). The sandblasted amalgam with Assure Plus ® showed the highest SBS ( P < 0.001). Samples mainly showed an ARI score = 1 and mix-mode failure. There was a statistically significant difference of surface roughness between nonsandblasted amalgam and sandblasted amalgam ( P < 0.05), but no significant differences among priming agents ( P > 0.05). Using adhesive primers with sandblasting together effectively enhances the SBS between orthodontic metal brackets and amalgam. The two primers with the ingredient methacryloxydecyl dihydrogen phosphate (MDP) monomer, Alloy Primer ® and Assure Plus ® , were the most effective. Including sandblasting in the treatment is essential to achieve the bonding strength required.
Sohn, Hoon-Sang; Shon, Min Soo; Lee, Kyung-Hag; Song, Si-Jung
2015-11-01
The aim of this study was to compare the clinical and radiographic outcomes between two different plating methods (superior vs. anteroinferior) in minimally invasive plate osteosynthesis (MIPO) for acute displaced clavicular shaft fractures. A prospective, randomized controlled trial was performed in a single centre. Nineteen patients were treated with superior plating and 18 with anteroinferior plating using the MIPO technique. A 3.5-mm locking reconstruction plate was bent preoperatively and applied to either the anteroinferior or superior aspect of the clavicle through two separate incisions. The operating time, time to union, the proportional length difference, complications, and functional outcome of the shoulder joint were evaluated using the Constant score and the University of California Los Angeles (UCLA) score. There was no statistically significant difference in the Constant score and UCLA score. The mean time to union was 16.8 weeks for superior plating and 17.1 weeks for anteroinferior plating (p=0.866). The average operation time was 77.2min in superior plating and 79.4min in anteroinferior plating (p=0.491). One patient in the superior plating group showed plate failure. Despite no significant difference, one patient had nonunion in the superior plating group (p>0.999). From a clinical perspective, although MIPO with anteroinferior plating provides better outcomes especially in complications without statistically significant difference, both plating methods provided satisfactory clinical and radiographic outcomes. Level I, a single-centre, prospective, randomized controlled trial. Copyright © 2015 Elsevier Ltd. All rights reserved.
Pulmonary capillary pressure in pulmonary hypertension.
Souza, Rogerio; Amato, Marcelo Britto Passos; Demarzo, Sergio Eduardo; Deheinzelin, Daniel; Barbas, Carmen Silvia Valente; Schettino, Guilherme Paula Pinto; Carvalho, Carlos Roberto Ribeiro
2005-04-01
Pulmonary capillary pressure (PCP), together with the time constants of the various vascular compartments, define the dynamics of the pulmonary vascular system. Our objective in the present study was to estimate PCPs and time constants of the vascular system in patients with idiopathic pulmonary arterial hypertension (IPAH), and compare them with these measures in patients with acute respiratory distress syndrome (ARDS). We conducted the study in two groups of patients with pulmonary hypertension: 12 patients with IPAH and 11 with ARDS. Four methods were used to estimate the PCP based on monoexponential and biexponential fitting of pulmonary artery pressure decay curves. PCPs in the IPAH group were considerably greater than those in the ARDS group. The PCPs measured using the four methods also differed significantly, suggesting that each method measures the pressure at a different site in the pulmonary circulation. The time constant for the slow component of the biexponential fit in the IPAH group was significantly longer than that in the ARDS group. The PCP in IPAH patients is greater than normal but methodological limitations related to the occlusion technique may limit interpretation of these data in isolation. Different disease processes may result in different times for arterial emptying, with resulting implications for the methods available for estimating PCP.
Ambardekar, Shubha; Shochet, Tara; Bracken, Hillary; Coyaji, Kurus; Winikoff, Beverly
2014-08-15
Trials of interventions for PPH prevention and treatment rely on different measurement methods for the quantification of blood loss and identification of PPH. This study's objective was to compare measures of blood loss obtained from two different measurement protocols frequently used in studies. Nine hundred women presenting for vaginal delivery were randomized to a direct method (a calibrated delivery drape) or an indirect method (a shallow bedpan placed below the buttocks and weighing the collected blood and blood-soaked gauze/pads). Blood loss was measured from immediately after delivery for at least one hour or until active bleeding stopped. Significantly greater mean blood loss was recorded by the direct than by the indirect measurement technique (253.9 mL and 195.3 mL, respectively; difference = 58.6 mL (95% CI: 31-86); p < 0.001). Almost twice as many women in the direct than in the indirect group measured blood loss > 500 mL (8.7% vs. 4.7%, p = 0.02). The study suggests a real and significant difference in blood loss measurement between these methods. Research using blood loss measurement as an endpoint needs to be interpreted taking measurement technique into consideration. This study has been registered at clinicaltrials.gov as NCT01885845.
McGrory, Ellen R; Brown, Colin; Bargary, Norma; Williams, Natalya Hunter; Mannix, Anthony; Zhang, Chaosheng; Henry, Tiernan; Daly, Eve; Nicholas, Sarah; Petrunic, Barbara M; Lee, Monica; Morrison, Liam
2017-02-01
The presence of arsenic in groundwater has become a global concern due to the health risks from drinking water with elevated concentrations. The Water Framework Directive (WFD) of the European Union calls for drinking water risk assessment for member states. The present study amalgamates readily available national and sub-national scale datasets on arsenic in groundwater in the Republic of Ireland. However, due to the presence of high levels of left censoring (i.e. arsenic values below an analytical detection limit) and changes in detection limits over time, the application of conventional statistical methods would inhibit the generation of meaningful results. In order to handle these issues several arsenic databases were integrated and the data modelled using statistical methods appropriate for non-detect data. In addition, geostatistical methods were used to assess principal risk components of elevated arsenic related to lithology, aquifer type and groundwater vulnerability. Geographic statistical methods were used to overcome some of the geographical limitations of the Irish Environmental Protection Agency (EPA) sample database. Nearest-neighbour inverse distance weighting (IDW) and local indicator of spatial association (LISA) methods were used to estimate risk in non-sampled areas. Significant differences were also noted between different aquifer lithologies, indicating that Rhyolite, Sandstone and Shale (Greywackes), and Impure Limestone potentially presented a greater risk of elevated arsenic in groundwaters. Significant differences also occurred among aquifer types with poorly productive aquifers, locally important fractured bedrock aquifers and regionally important fissured bedrock aquifers presenting the highest potential risk of elevated arsenic. No significant differences were detected among different groundwater vulnerability groups as defined by the Geological Survey of Ireland. This research will assist management and future policy directions of groundwater resources at EU level and guide future research focused on understanding arsenic mobilisation processes to facilitate in guiding future development, testing and treatment requirements of groundwater resources. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Gu, Junhua; Xu, Haiguang; Wang, Jingying; An, Tao; Chen, Wen
2013-08-01
We propose a continuous wavelet transform based non-parametric foreground subtraction method for the detection of redshifted 21 cm signal from the epoch of reionization. This method works based on the assumption that the foreground spectra are smooth in frequency domain, while the 21 cm signal spectrum is full of saw-tooth-like structures, thus their characteristic scales are significantly different. We can distinguish them in the wavelet coefficient space easily and perform the foreground subtraction. Compared with the traditional spectral fitting based method, our method is more tolerant to complex foregrounds. Furthermore, we also find that when the instrument has uncorrected response error, our method can also work significantly better than the spectral fitting based method. Our method can obtain similar results with the Wp smoothing method, which is also a non-parametric method, but our method consumes much less computing time.
Dai, F F; Liu, Y; Xu, T M; Chen, G
2018-04-18
To explore a cone beam computed tomography (CBCT)-independent method for mandibular digital dental cast superimposition to evaluate three-dimensional (3D) mandibular tooth movement after orthodontic treatment in adults, and to evaluate the accuracy of this method. Fifteen post-extraction orthodontic treatment adults from the Department of Orthodontics, Peking University School and Hospital of Stomatology were included. All the patients had four first premolars extracted, and were treated with straight wire appliance. The pre- and post-treatment plaster dental casts and craniofacial CBCT scans were obtained. The plaster dental casts were transferred to digital dental casts by 3D laser scanning, and lateral cephalograms were created from the craniofacial CBCT scans by orthogonal projection. The lateral cephalogram-based mandibular digital dental cast superimposition was achieved by sequential maxillary dental cast superimposition registered on the palatal stable region, occlusal transfer, and adjustment of mandibular rotation and translation obtained from lateral cephalogram superimposition. The accuracy of the lateral cephalogram-based mandibular digital dental cast superimposition method was evaluated with the CBCT-based mandibular digital dental cast superimposition method as the standard reference. After mandibular digital dental cast superimposition using both methods, 3D coordinate system was established, and 3D displacements of the lower bilateral first molars, canines and central incisors were measured. Differences between the two superimposition methods in tooth displacement measurements were assessed using the paired t-test with the level of statistical significance set at P<0.05. No significant differences were found between the lateral cephalogram-based and CBCT-based mandibular digital dental cast superimposition methods in 3D displacements of the lower first molars, and sagittal and vertical displacements of the canines and central incisors; transverse displacements of the canines and central incisors differed by (0.3±0.5) mm with statistical significance. The lateral cephalogram-based mandibular digital dental cast superimposition method has the similar accuracy as the CBCT-based mandibular digital dental cast superimposition method in 3D evaluation of mandibular orthodontic tooth displacement, except for minor differences for the transverse displacements of anterior teeth. This method is applicable to adult patients with conventional orthodontic treatment records, especially the previous precious orthodontic data in the absence of CBCT scans.
Gonzalo, Esther; Suárez, María J; Serrano, Benjamin; Lozano, José F L
2009-01-01
The purpose of this study was to compare two measurement methods for the external marginal fit of zirconia posterior fixed partial dentures (FPDs) fabricated using computer-aided design/manufacturing technology and metal-ceramic posterior FPDs fabricated using the conventional lost-wax technique. The null hypothesis was that there would be no differences between the measurement methods. Forty standardized steel specimens were prepared to receive posterior three-unit FPDs. Specimens were divided into four groups (n = 10): (1) metal-ceramic, (2) Procera Bridge Zirconia, (3) Lava AllCeramic System, and (4) Vita In-Ceram YZ 2000. All FPDs were luted with glass-ionomer cement (Ketac Cem EasyMix, 3M ESPE). Two measurement methods were used to analyze marginal fit: an image analysis (IA) program and a scanning electron microscope (SEM) (JEOL JSM-6400) with magnifications of 340 and 31,000, respectively. Marginal fit was measured at the same point on each abutment. Significant interaction was observed between measurement method and material (P = .0019). Therefore, the measurement method is not independent of the restoration material. Differences among groups were observed for IA (P = .0001) and SEM (P = .0013). Significant differences were observed for the Procera (P = .0050) and metal-ceramic (P = .0039) specimen groups when both measurement methods were evaluated separately. Accuracy of fit achieved by the four groups analyzed was within the range of clinical acceptance, yielding Procera Bridge Zirconia to have the best marginal fit using both measurement methods.
Guo, Xinyu; Dominick, Kelli C.; Minai, Ali A.; Li, Hailong; Erickson, Craig A.; Lu, Long J.
2017-01-01
The whole-brain functional connectivity (FC) pattern obtained from resting-state functional magnetic resonance imaging data are commonly applied to study neuropsychiatric conditions such as autism spectrum disorder (ASD) by using different machine learning models. Recent studies indicate that both hyper- and hypo- aberrant ASD-associated FCs were widely distributed throughout the entire brain rather than only in some specific brain regions. Deep neural networks (DNN) with multiple hidden layers have shown the ability to systematically extract lower-to-higher level information from high dimensional data across a series of neural hidden layers, significantly improving classification accuracy for such data. In this study, a DNN with a novel feature selection method (DNN-FS) is developed for the high dimensional whole-brain resting-state FC pattern classification of ASD patients vs. typical development (TD) controls. The feature selection method is able to help the DNN generate low dimensional high-quality representations of the whole-brain FC patterns by selecting features with high discriminating power from multiple trained sparse auto-encoders. For the comparison, a DNN without the feature selection method (DNN-woFS) is developed, and both of them are tested with different architectures (i.e., with different numbers of hidden layers/nodes). Results show that the best classification accuracy of 86.36% is generated by the DNN-FS approach with 3 hidden layers and 150 hidden nodes (3/150). Remarkably, DNN-FS outperforms DNN-woFS for all architectures studied. The most significant accuracy improvement was 9.09% with the 3/150 architecture. The method also outperforms other feature selection methods, e.g., two sample t-test and elastic net. In addition to improving the classification accuracy, a Fisher's score-based biomarker identification method based on the DNN is also developed, and used to identify 32 FCs related to ASD. These FCs come from or cross different pre-defined brain networks including the default-mode, cingulo-opercular, frontal-parietal, and cerebellum. Thirteen of them are statically significant between ASD and TD groups (two sample t-test p < 0.05) while 19 of them are not. The relationship between the statically significant FCs and the corresponding ASD behavior symptoms is discussed based on the literature and clinician's expert knowledge. Meanwhile, the potential reason of obtaining 19 FCs which are not statistically significant is also provided. PMID:28871217
Klein, Christian; Kinz, Wieland; Zembsch, Alexander; Groll-Knapp, Elisabeth; Kundi, Michael
2014-04-21
Currently, the metatarsophalangeal angle (hallux valgus angle) is measured based on radiographic images. However, using X-ray examinations for epidemiological or screening purposes would be unethical, especially in children. For this reason it is discussed to measure the hallux valgus angle of the margo medialis pedis (medial border of the foot) documented on foot outline drawings or foot scans. As a first step on the way to prove the validity of those approaches this study assesses the hallux valgus angle measured on the margo medialis pedis based on the same x-ray pictures as the metatarsophalangeal hallux valgus. Radiographic images of the foot were obtained from patients with symptomatic hallux valgus malformation. Twelve sets of contact copies of the 63 originals were made, and were marked and measured according to three different methods, each one performed by two observers and with two repeated measurements. Thus, data sets from 756 individual assessments were entered into the multifactorial statistical analysis.Comparisons were made between the angle of the margo medialis pedis and the metatarsophalangeal angle, which was determined by two different methods. To determine the inter- and intraobserver reliability of the different methods, each assessment was conducted by two independent experts and repeated after a period of several weeks. The correlations between the hallux valgus angles determined by the three different methods were all above r=0.89 (p<0.001) and thus highly significant. The values obtained by measuring the margo medialis pedis angle, however, were on average 4.8 degrees smaller than the metatarsophalangeal angles. No significant differences were found between the observers. No systematic deviations for any observer between repeated measurements were detected. Measurements of the radiographic hallux angle of the margo medialis pedis are reliable and show high correlation with the metatarsophalangeal angle. Because the hallux valgus angles based on margo medialis pedis measurements were slightly but statistically significantly smaller, these measurements should be considered conservative estimates of the metatarsophalangeal angle. Significant differences between hallux valgus angles based on radiographic and non-radiographic material are unlikely. However this question has to be treated in a second stage in detail.
The Role of Attention in Somatosensory Processing: A Multi-trait, Multi-method Analysis
Puts, Nicolaas A. J.; Mahone, E. Mark; Edden, Richard A. E.; Tommerdahl, Mark; Mostofsky, Stewart H.
2016-01-01
Sensory processing abnormalities in autism have largely been described by parent report. This study used a multi-method (parent-report and measurement), multi-trait (tactile sensitivity and attention) design to evaluate somatosensory processing in ASD. Results showed multiple significant within-method (e.g., parent report of different traits)/cross-trait (e.g., attention and tactile sensitivity) correlations, suggesting that parent-reported tactile sensory dysfunction and performance-based tactile sensitivity describe different behavioral phenomena. Additionally, both parent-reported tactile functioning and performance-based tactile sensitivity measures were significantly associated with measures of attention. Findings suggest that sensory (tactile) processing abnormalities in ASD are multifaceted, and may partially reflect a more global deficit in behavioral regulation (including attention). Challenges of relying solely on parent-report to describe sensory difficulties faced by children/families with ASD are also highlighted. PMID:27448580
Clasey, Jody L; Gater, David R
2005-11-01
To compare (1) total body volume (V(b)) and density (D(b)) measurements obtained by hydrostatic weighing (HW) and air displacement plethysmography (ADP) in adults with spinal cord injury (SCI); (2) measured and predicted thoracic gas volume (V(TG)); and (3) differences in percentage of fat measurements using ADP-obtained D(b) and HW-obtained D(b) measures that were interchanged in a 4-compartment body composition model (4-comp %fat). Twenty adults with SCI underwent ADP and V(TG), and HW testing. In a subgroup (n=13) of subjects, 4-comp %fat procedures were computed. Research laboratories in a university setting. Twenty adults with SCI below the T3 vertebrae and motor complete paraplegia. Not applicable. Statistical analyses, including determination of group mean differences, shared variance, total error, and 95% confidence intervals. The 2 methods yielded small yet significantly different V(b) and D(b). The groups' mean V(TG) did not differ significantly, but the large relative differences indicated an unacceptable amount of individual error. When the 4-comp %fat measurements were compared, there was a trend toward significant differences (P=.08). ADP is a valid alternative method of determining the V(b) and D(b) in adults with SCI; however, the predicted V(TG) should be used with caution.
Acker, Jason P; Hansen, Adele L; Kurach, Jayme D R; Turner, Tracey R; Croteau, Ioana; Jenkins, Craig
2014-10-01
Canadian Blood Services has been conducting quality monitoring of red blood cell (RBC) components since 2005, a period spanning the implementation of semiautomated component production. The aim was to compare the quality of RBC components produced before and after this production method change. Data from 572 RBC units were analyzed, categorized by production method: Method 1, RBC units produced by manual production methods; Method 2, RBC units produced by semiautomated production and the buffy coat method; and Method 3, RBC units produced by semiautomated production and the whole blood filtration method. RBC units were assessed using an extensive panel of in vitro tests, encompassing regulated quality control criteria such as hematocrit (Hct), hemolysis, and hemoglobin (Hb) levels, as well as adenosine triphosphate, 2,3-diphosphoglycerate, extracellular K(+) and Na(+) levels, methemoglobin, p50, RBC indices, and morphology. Throughout the study, all RBC units met mandated Canadian Standards Association guidelines for Hb and Hct, and most (>99%) met hemolysis requirements. However, there were significant differences among RBC units produced using different methods. Hb content was significantly lower in RBC units produced by Method 2 (51.5 ± 5.6 g/unit; p < 0.001). At expiry, hemolysis was lowest in Method 2-produced RBC units (p < 0.05) and extracellular K(+) levels were lowest in units produced by Method 1 (p < 0.001). While overall quality was similar before and after the production method change, the observed differences, although small, indicate a lack of equivalency across RBC products manufactured by different methods. © 2014 AABB.
NASA Astrophysics Data System (ADS)
Fathurrohman, Maman; Porter, Anne; Worthy, Annette L.
2014-07-01
In this paper, the use of guided hyperlearning, unguided hyperlearning, and conventional learning methods in mathematics are compared. The design of the research involved a quasi-experiment with a modified single-factor multiple treatment design comparing the three learning methods, guided hyperlearning, unguided hyperlearning, and conventional learning. The participants were from three first-year university classes, numbering 115 students in total. Each group received guided, unguided, or conventional learning methods in one of the three different topics, namely number systems, functions, and graphing. The students' academic performance differed according to the type of learning. Evaluation of the three methods revealed that only guided hyperlearning and conventional learning were appropriate methods for the psychomotor aspects of drawing in the graphing topic. There was no significant difference between the methods when learning the cognitive aspects involved in the number systems topic and the functions topic.
Bayesian analysis of multimethod ego-depletion studies favours the null hypothesis.
Etherton, Joseph L; Osborne, Randall; Stephenson, Katelyn; Grace, Morgan; Jones, Chas; De Nadai, Alessandro S
2018-04-01
Ego-depletion refers to the purported decrease in performance on a task requiring self-control after engaging in a previous task involving self-control, with self-control proposed to be a limited resource. Despite many published studies consistent with this hypothesis, recurrent null findings within our laboratory and indications of publication bias have called into question the validity of the depletion effect. This project used three depletion protocols involved three different depleting initial tasks followed by three different self-control tasks as dependent measures (total n = 840). For each method, effect sizes were not significantly different from zero When data were aggregated across the three different methods and examined meta-analytically, the pooled effect size was not significantly different from zero (for all priors evaluated, Hedges' g = 0.10 with 95% credibility interval of [-0.05, 0.24]) and Bayes factors reflected strong support for the null hypothesis (Bayes factor > 25 for all priors evaluated). © 2018 The British Psychological Society.
NASA Astrophysics Data System (ADS)
Chauhan, Lalita; Bokolia, Renuka; Sreenivas, K.
2016-05-01
Structural properties of Nickel ferrite (NiFe2O4) ceramics prepared from powders derived from sol gel auto-combustion method using different fuels (citric acid, glycine and Dl-alanine) are compared. Changes in the structural properties at different sintering temperatures are investigated. X-ray diffraction (XRD) confirms the formation of single phase material with cubic structure. Ceramics prepared using the different powders obtained from different fuels show that that there are no significant changes in lattice parameters. However increasing sintering temperatures show significant improvement in density and grain size. The DL-alanine fuel is found to be the most effective fuel for producing NIFe2O4 powders by the sol-gel auto combustion method and yields highly crystalline powders in the as-burnt stage itself at a low temperature (80 °C). Subsequent use of the powders in ceramic manufacturing produces dense NiFe2O4 ceramics with a uniform microstructure and a large grain size.
Obadina, Adewale O; Oyewole, Olusola B; Williams, Oluwasolabomi E
2013-07-01
This study was carried out to investigate and improve the traditional processing method and nutritional quality of the traditional cassava snack (Ajogun). Cassava root (Manihot esculenta Crantz L.) of TME 419 variety was processed into mash (40% moisture content). The cassava mash was mixed into different blends to produce fried traditional "Ajogun", fried and baked extrudates (modified Ajogun) as snacks. These products were analyzed to determine the proximate composition including carbohydrate, fat, protein, fiber, ash, and moisture contents and functional properties such as bulk density. The results obtained for the moisture, fat, protein, and ash contents showed significant difference (P < 0.05) between the control sample and the extrudates. However, there was no significant difference (P > 0.05) in the carbohydrate and fiber contents between the three samples. There was no significant difference (P > 0.05) in the bulk density of the snacks. Also, sensory evaluation was carried out on the cassava-based snacks using the 9-point hedonic scale to determine the degree of acceptability. Results obtained showed significant difference (P < 0.05) between the extrudates and control sample in terms of appearance, taste, flavor, color, aroma, texture, and overall acceptability. The highest acceptability level of the product was at 8.04 for the control sample (traditional Ajogun). This study has shown that "Ajogun", which is a lesser known cassava product, is rich in protein and fat.
Vijayapushpam, T; Subba Rao, G M; Antony, Grace Maria; Rao, D Raghunatha
2008-06-01
Nutrition education for student volunteers can enhance their skills, and they can act as change agents in the community. There is a dearth of data from India on the effectiveness of different communication tools in providing nutrition education to student volunteers. This study aims to examine the comparative effectiveness of two different methods of communication--lectures in the classroom aided by print material, and a televised version of a local folk-dance form--for providing nutrition education to student community volunteers in a South Indian state. Interventions were conducted during two mega-camps of student volunteers (camps 1 and 2) with 70 and 137 participants, respectively. Their knowledge levels were tested at baseline. Camp 1 received the lecture intervention and camp 2 the televised folk-dance intervention. Knowledge scores were measured before and after the intervention in each camp, and the two camps were compared for significant improvements in knowledge. At baseline, the knowledge levels of students in both camps were comparable. Significant improvement in knowledge was observed in both camps after intervention (p < .05). Although there was no significant difference between the camps in improvement in knowledge, a significant difference was observed when only the positive increments (improvement over baseline) were compared. The televised version of the folk-dance form was better in bringing about positive increment.
Antioxidant activities of different colored sweet bell peppers (Capsicum annuum L.).
Sun, T; Xu, Z; Wu, C-T; Janes, M; Prinyawiwatkul, W; No, H K
2007-03-01
Antioxidant compounds and their antioxidant activity in 4 different colored (green, yellow, orange, and red) sweet bell peppers (Capsicum annuum L.) were investigated. The total phenolics content of green, yellow, orange, and red peppers determined by the Folin-Ciocalteau method were 2.4, 3.3, 3.4, and 4.2 micromol catechin equivalent/g fresh weight, respectively. The red pepper had significantly higher total phenolics content than the green pepper. Among the 4 different colored peppers, red pepper contained a higher level of beta-carotene (5.4 microg/g), capsanthin (8.0 microg/g), quercetin (34.0 microg/g), and luteolin (11.0 microg/g). The yellow pepper had the lowest beta-carotene content (0.2 microg/g), while the green one had undetectable capsanthin and the lowest content of luteolin (2.0 microg/g). The free radical scavenging abilities of peppers determined by the 2,2'-diphenyl-1-picrylhydrazyl (DPPH) method were lowest for the green pepper (2.1 micromol Trolox equivalent/g) but not significantly different from the other 3 peppers. All 4 colored peppers exhibited significant abilities in preventing the oxidation of cholesterol or docosahexaenoic acid (DHA) (C22:6) during heating. However, these 4 peppers did not show significant differences in their abilities in preventing cholesterol oxidation. The green pepper showed slightly higher capability in preventing the oxidation of DHA compared to the other 3 peppers.
Roh, Hyun Cheol; Baek, Sehyun; Lee, Hwa; Chang, Minwook
2016-06-01
To evaluate differences in the surgical outcomes of endoscopic dacryocystorhinostomy (DCR) according to four different surgical methods. This retrospective study included 222 patients who underwent endoscopic DCR from 2011 to 2013. All patients were assigned to one of four groups according to instruments for incision of nasal mucosa and the formation of mucosal flap: group 1, a sickle knife with mucosal flap; group 2, a sickle knife without mucosal flap; group 3, electrocautery with mucosal flap; and group 4, electrocautery without mucosal flap. The follow up period was at least 6 months. There were 33 eyes in group 1, 44 eyes in group 2, 49 eyes in group 3, and 97 eyes in group 4. There were no significant differences in success rate between groups (P = 0.878). Wound healing time was significantly different between groups (P < 0.001). In post hoc analysis, wound healing time was significantly shorter in group 1 and group 2 than in group 3 and group 4. The vertical ostium size and postsurgical complication were not significantly different between groups. The use of cold instruments such as sickle knife may be more helpful and effective for shortening wound healing time rather than making mucosal flaps in endoscopic DCR. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.
Measurement of biochemical oxygen demand of the leachates.
Fulazzaky, Mohamad Ali
2013-06-01
Biochemical oxygen demand (BOD) of the leachates originally from the different types of landfill sites was studied based on the data measured using the two manometric methods. The measurements of BOD using the dilution method were carried out to assess the typical physicochemical and biological characteristics of the leachates together with some other parameters. The linear regression analysis was used to predict rate constants for biochemical reactions and ultimate BOD values of the different leachates. The rate of a biochemical reaction implicated in microbial biodegradation of pollutants depends on the leachate characteristics, mass of contaminant in the leachate, and nature of the leachate. Character of leachate samples for BOD analysis of using the different methods may differ significantly during the experimental period, resulting in different BOD values. This work intends to verify effect of the different dilutions for the manometric method tests on the BOD concentrations of the leachate samples to contribute to the assessment of reaction rate and microbial consumption of oxygen.
McNulty, Breige; Kehoe, Laura; Evans, Katie; Walton, Janette; Flynn, Albert
2017-01-01
Background The application of technology in the area of dietary assessment has resulted in the development of an array of tools, which are often specifically designed for a particular country or region. Objective The aim of this study was to describe the development, validation, and user evaluation of a Web-based dietary assessment tool “Foodbook24.” Methods Foodbook24 is a Web-based, dietary assessment tool consisting of a 24-hour dietary recall (24HDR) and food frequency questionnaire (FFQ) alongside supplementary questionnaires. Validity of the 24HDR component was assessed by 40 participants, who completed 3 nonconsecutive, self-administered 24HDR using Foodbook24 and a 4-day semi-weighed food diary at separate time points. Participants also provided fasted blood samples and 24-hour urine collections for the identification of biomarkers of nutrient and food group intake during each recording period. Statistical analyses on the nutrient and food group intake data derived from each method were performed in SPSS version 20.0 (SPSS Inc). Mean nutrient intakes (and standard deviations) recorded using each method of dietary assessment were calculated. Spearman and Pearson correlations, Wilcoxon Signed Rank and Paired t test were used to investigate the agreement and differences between the nutritional output from Foodbook24 (test method) and the 4-day semi-weighed food diary (reference method). Urinary and plasma biomarkers of nutrient intake were used as an objective validation of Foodbook24. To investigate the user acceptability of Foodbook24, participants from different studies involved with Foodbook24 were asked to complete an evaluation questionnaire. Results For nutrient intake, correlations between the dietary assessment methods were acceptable to very good in strength and statistically significant (range r=.32 to .75). There were some significant differences between reported mean intakes of micronutrients recorded by both methods; however, with the exception of protein (P=.03), there were no significant differences in the reporting of energy or macronutrient intake. Of the 19 food groups investigated in this analysis, there were significant differences between 6 food groups reported by both methods. Spearman correlations for biomarkers of nutrient and food group intake and reported intake were similar for both methods. A total of 118 participants evaluated the acceptability of Foodbook24. The tool was well-received and the majority, 67.8% (80/118), opted for Foodbook24 as the preferred method for future dietary intake assessment when compared against a traditional interviewer led recall and semi-weighed food diary. Conclusions The results of this study demonstrate the validity and user acceptability of Foodbook24. The results also highlight the potential of Foodbook24, a Web-based dietary assessment method, and present a viable alternative to nutritional surveillance in Ireland. PMID:28495662
Khoshkholgh, Roghaie; Keshavarz, Tahereh; Moshfeghy, Zeinab; Akbarzadeh, Marzieh; Asadi, Nasrin; Zare, Najaf
2016-01-01
Objective: To compare the effects of two auditory methods by mother and fetus on the results of NST in 2011-2012. Materials and methods: In this single-blind clinical trial, 213 pregnant women with gestational age of 37-41 weeks who had no pregnancy complications were randomly divided into 3 groups (auditory intervention for mother, auditory intervention for fetus, and control) each containing 71 subjects. In the intervention groups, music was played through the second 10 minutes of NST. The three groups were compared regarding baseline fetal heart rate and number of accelerations in the first and second 10 minutes of NST. The data were analyzed using one-way ANOVA, Kruskal-Wallis, and paired T-test. Results: The results showed no significant difference among the three groups regarding baseline fetal heart rate in the first (p = 0.945) and second (p = 0.763) 10 minutes. However, a significant difference was found among the three groups concerning the number of accelerations in the second 10 minutes. Also, a significant difference was observed in the number of accelerations in the auditory intervention for mother (p = 0.013) and auditory intervention for fetus groups (p < 0.001). The difference between the number of accelerations in the first and second 10 minutes was also statistically significant (p = 0.002). Conclusion: Music intervention was effective in the number of accelerations which is the indicator of fetal health. Yet, further studies are required to be conducted on the issue. PMID:27385971
Jivănescu, Anca; Bratu, Dana Cristina; Tomescu, Lucian; Măroiu, Alexandra Cristina; Popa, George; Bratu, Emanuel Adrian
2015-01-01
Using two measurement methods (a three-dimensional laser scanning system and a digital caliper), this study compares the lower face morphology of complete edentulous patients, before and after prosthodontic rehabilitation with bimaxillary complete dentures. Fourteen edentulous patients were randomly selected from the Department of Prosthodontics, at the Faculty of Dental Medicine, "Victor Babes" University of Medicine and Pharmacy, Timisoara, Romania. The changes that occurred in the lower third of the face after prosthodontic treatment were assessed quantitatively by measuring the vertical projection of the distances between two sets of anthropometric landmarks: Subnasale - cutaneous Pogonion (D1) and Labiale superius - Labiale inferius (D2). A two-way repeated measures ANOVA model design was carried out to test for significant interactions, main effects and differences between the two types of measuring devices and between the initial and final rehabilitation time points. The main effect of the type of measuring device showed no statistically significant differences in the measured distances (p=0.24 for D1 and p=0.39 for D2), between the initial and the final rehabilitation time points. Regarding the main effect of time, there were statistically significant differences in both the measured distances D1 and D2 (p=0.001), between the initial and the final rehabilitation time points. The two methods of measurement were equally reliable in the assessment of lower face morphology changes in edentulous patients after prosthodontic rehabilitation with bimaxillary complete dentures. The differences between the measurements taken before and after prosthodontic rehabilitation proved to be statistically significant.
ERIC Educational Resources Information Center
Taylor, Mark; Callahan, Jamie L.
2005-01-01
We compare different epistemological frameworks for the effective collection of creativity data. We suggest that researchers' epistemological approaches can significantly influence collection methods and subsequent outcomes. Classic sociological epistemological approaches--functionalism, interpretivism, radical humanism, and radical structuralism…
Digholkar, Shruti; Madhav, V. N. V.; Palaskar, Jayant
2016-01-01
Purpose: The purpose of this study was to evaluate and compare the flexural strength and microhardness of provisional restorative materials fabricated utilizing rapid prototyping (RP), Computer Assisted Designing and Computer Assisted Milling (CAD-CAM) and conventional method. Materials and Methods: Twenty specimens of dimensions 25 mm × 2 mm × 2 mm (ADA-ANSI specification #27) were fabricated each using: (1) Three dimensional (3D) printed light-cured micro-hybrid filled composite by RP resin group, (2) a milled polymethyl methacrylate (CH) using CAD-CAM (CC resin group), and (3) a conventionally fabricated heat activated polymerized CH resin group. Flexural strength and microhardness were measured and values obtained were evaluated. Results: The measured mean flexural strength values (MegaPascals) were 79.54 (RP resin group), 104.20 (CC resin group), and 95.58 (CH resin group). The measured mean microhardness values (Knoop hardness number) were 32.77 (RP resin group), 25.33 (CC resin group), and 27.36 (CH resin group). The analysis of variance (ANOVA) test shows that there is statistically significant difference in the flexural strength values of the three groups (P < 0.05). According to the pairwise comparison of Tukey's honest significant difference (HSD) test, flexural strength values of CC resin group and CH resin group were higher and statistically significant than those of the RP resin group (P < 0.05). However, there was no significant difference between flexural strength values of CC resin and CH resin group (P = 0.64). The difference in microhardness values of the three groups was statistically significant according to ANOVA as well as the intergroup comparison done using the Tukey's HSD (post hoc) test (P < 0.05). Conclusions: CC-based CH had the highest flexural strength whereas RP-based 3D printed and light cured micro-hybrid filled composite had the highest microhardness. PMID:27746595
Saraç, Y Şinasi; Külünk, Tolga; Elekdağ-Türk, Selma; Saraç, Duygu; Türk, Tamer
2011-12-01
The aims of this study were to investigate the effects of two surface-conditioning methods on the shear bond strength (SBS) of metal brackets bonded to three different all-ceramic materials, and to evaluate the mode of failure after debonding. Twenty feldspathic, 20 fluoro-apatite, and 20 leucite-reinforced ceramic specimens were examined following two surface-conditioning methods: air-particle abrasion (APA) with 25 μm Al(2)O(3) and silica coating with 30 μm Al(2)O(3) particles modified by silica. After silane application, metal brackets were bonded with light cure composite and then stored in distilled water for 1 week and thermocycled (×1000 at 5-55°C for 30 seconds). The SBS of the brackets was measured on a universal testing machine. The ceramic surfaces were examined with a stereomicroscope to determine the amount of composite resin remaining using the adhesive remnant index. Two-way analysis of variance, Tukey's multiple comparison test, and Weibull analysis were used for evaluation of SBS. The lowest SBS was with APA for the fluoro-apatite ceramic (11.82 MPa), which was not significantly different from APA for the feldspathic ceramic (13.58 MPa). The SBS for the fluoro-apatite ceramic was significantly lower than that of leucite-reinforced ceramic with APA (14.82 MPa). The highest SBS value was obtained with silica coating of the leucite-reinforced ceramic (24.17 MPa), but this was not significantly different from the SBS for feldspathic and fluoro-apatite ceramic (23.51 and 22.18 MPa, respectively). The SBS values with silica coating showed significant differences from those of APA. For all samples, the adhesive failures were between the ceramic and composite resin. No ceramic fractures or cracks were observed. Chairside tribochemical silica coating significantly increased the mean bond strength values.
Bergman, Lars G; Fors, Uno GH
2008-01-01
Background Correct diagnosis in psychiatry may be improved by novel diagnostic procedures. Computerized Decision Support Systems (CDSS) are suggested to be able to improve diagnostic procedures, but some studies indicate possible problems. Therefore, it could be important to investigate CDSS systems with regard to their feasibility to improve diagnostic procedures as well as to save time. Methods This study was undertaken to compare the traditional 'paper and pencil' diagnostic method SCID1 with the computer-aided diagnostic system CB-SCID1 to ascertain processing time and accuracy of diagnoses suggested. 63 clinicians volunteered to participate in the study and to solve two paper-based cases using either a CDSS or manually. Results No major difference between paper and pencil and computer-supported diagnosis was found. Where a difference was found it was in favour of paper and pencil. For example, a significantly shorter time was found for paper and pencil for the difficult case, as compared to computer support. A significantly higher number of correct diagnoses were found in the diffilt case for the diagnosis 'Depression' using the paper and pencil method. Although a majority of the clinicians found the computer method supportive and easy to use, it took a longer time and yielded fewer correct diagnoses than with paper and pencil. Conclusion This study could not detect any major difference in diagnostic outcome between traditional paper and pencil methods and computer support for psychiatric diagnosis. Where there were significant differences, traditional paper and pencil methods were better than the tested CDSS and thus we conclude that CDSS for diagnostic procedures may interfere with diagnosis accuracy. A limitation was that most clinicians had not previously used the CDSS system under study. The results of this study, however, confirm that CDSS development for diagnostic purposes in psychiatry has much to deal with before it can be used for routine clinical purposes. PMID:18261222
Wang, Ling-jia; Kissler, Hermann J; Wang, Xiaojun; Cochet, Olivia; Krzystyniak, Adam; Misawa, Ryosuke; Golab, Karolina; Tibudan, Martin; Grzanka, Jakub; Savari, Omid; Grose, Randall; Kaufman, Dixon B; Millis, Michael; Witkowski, Piotr
2015-01-01
Pancreatic islet mass, represented by islet equivalent (IEQ), is the most important parameter in decision making for clinical islet transplantation. To obtain IEQ, the sample of islets is routinely counted manually under a microscope and discarded thereafter. Islet purity, another parameter in islet processing, is routinely acquired by estimation only. In this study, we validated our digital image analysis (DIA) system developed using the software of Image Pro Plus for islet mass and purity assessment. Application of the DIA allows to better comply with current good manufacturing practice (cGMP) standards. Human islet samples were captured as calibrated digital images for the permanent record. Five trained technicians participated in determination of IEQ and purity by manual counting method and DIA. IEQ count showed statistically significant correlations between the manual method and DIA in all sample comparisons (r >0.819 and p < 0.0001). Statistically significant difference in IEQ between both methods was found only in High purity 100μL sample group (p = 0.029). As far as purity determination, statistically significant differences between manual assessment and DIA measurement was found in High and Low purity 100μL samples (p<0.005), In addition, islet particle number (IPN) and the IEQ/IPN ratio did not differ statistically between manual counting method and DIA. In conclusion, the DIA used in this study is a reliable technique in determination of IEQ and purity. Islet sample preserved as a digital image and results produced by DIA can be permanently stored for verification, technical training and islet information exchange between different islet centers. Therefore, DIA complies better with cGMP requirements than the manual counting method. We propose DIA as a quality control tool to supplement the established standard manual method for islets counting and purity estimation. PMID:24806436
Differences in sampling techniques on total post-mortem tryptase.
Tse, R; Garland, J; Kesha, K; Elstub, H; Cala, A D; Ahn, Y; Stables, S; Palmiere, C
2018-05-01
The measurement of mast cell tryptase is commonly used to support the diagnosis of anaphylaxis. In the post-mortem setting, the literature recommends sampling from peripheral blood sources (femoral blood) but does not specify the exact sampling technique. Sampling techniques vary between pathologists, and it is unclear whether different sampling techniques have any impact on post-mortem tryptase levels. The aim of this study is to compare the difference in femoral total post-mortem tryptase levels between two sampling techniques. A 6-month retrospective study comparing femoral total post-mortem tryptase levels between (1) aspirating femoral vessels with a needle and syringe prior to evisceration and (2) femoral vein cut down during evisceration. Twenty cases were identified, with three cases excluded from analysis. There was a statistically significant difference (paired t test, p < 0.05) between mean post-mortem tryptase by aspiration (10.87 ug/L) and by cut down (14.15 ug/L). The mean difference between the two methods was 3.28 ug/L (median, 1.4 ug/L; min, - 6.1 ug/L; max, 16.5 ug/L; 95% CI, 0.001-6.564 ug/L). Femoral total post-mortem tryptase is significantly different, albeit by a small amount, between the two sampling methods. The clinical significance of this finding and what factors may contribute to it are unclear. When requesting post-mortem tryptase, the pathologist should consider documenting the exact blood collection site and method used for collection. In addition, blood samples acquired by different techniques should not be mixed together and should be analyzed separately if possible.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nyflot, Matthew J., E-mail: nyflot@uw.edu; Lee, Tzu-Cheng; Alessio, Adam M.
Purpose: Respiratory-correlated positron emission tomography (PET/CT) 4D PET/CT is used to mitigate errors from respiratory motion; however, the optimal CT attenuation correction (CTAC) method for 4D PET/CT is unknown. The authors performed a phantom study to evaluate the quantitative performance of CTAC methods for 4D PET/CT in the ground truth setting. Methods: A programmable respiratory motion phantom with a custom movable insert designed to emulate a lung lesion and lung tissue was used for this study. The insert was driven by one of five waveforms: two sinusoidal waveforms or three patient-specific respiratory waveforms. 3DPET and 4DPET images of the phantommore » under motion were acquired and reconstructed with six CTAC methods: helical breath-hold (3DHEL), helical free-breathing (3DMOT), 4D phase-averaged (4DAVG), 4D maximum intensity projection (4DMIP), 4D phase-matched (4DMATCH), and 4D end-exhale (4DEXH) CTAC. Recovery of SUV{sub max}, SUV{sub mean}, SUV{sub peak}, and segmented tumor volume was evaluated as RC{sub max}, RC{sub mean}, RC{sub peak}, and RC{sub vol}, representing percent difference relative to the static ground truth case. Paired Wilcoxon tests and Kruskal–Wallis ANOVA were used to test for significant differences. Results: For 4DPET imaging, the maximum intensity projection CTAC produced significantly more accurate recovery coefficients than all other CTAC methods (p < 0.0001 over all metrics). Over all motion waveforms, ratios of 4DMIP CTAC recovery were 0.2 ± 5.4, −1.8 ± 6.5, −3.2 ± 5.0, and 3.0 ± 5.9 for RC{sub max}, RC{sub peak}, RC{sub mean}, and RC{sub vol}. In comparison, recovery coefficients for phase-matched CTAC were −8.4 ± 5.3, −10.5 ± 6.2, −7.6 ± 5.0, and −13.0 ± 7.7 for RC{sub max}, RC{sub peak}, RC{sub mean}, and RC{sub vol}. When testing differences between phases over all CTAC methods and waveforms, end-exhale phases were significantly more accurate (p = 0.005). However, these differences were driven by the patient-specific respiratory waveforms; when testing patient and sinusoidal waveforms separately, patient waveforms were significantly different between phases (p < 0.0001) while the sinusoidal waveforms were not significantly different (p = 0.98). When considering only the subset of 4DMATCH images that corresponded to the end-exhale image phase, 4DEXH, mean and interquartile range were similar to 4DMATCH but variability was considerably reduced. Conclusions: Comparative advantages in accuracy and precision of SUV metrics and segmented volumes were demonstrated with the use of the maximum intensity projection and end-exhale CT attenuation correction. While respiratory phase-matched CTAC should in theory provide optimal corrections, image artifacts and differences in implementation of 4DCT and 4DPET sorting can degrade the benefit of this approach. These results may be useful to guide the implementation, analysis, and development of respiratory-correlated thoracic PET/CT in the radiation oncology and diagnostic settings.« less
Faramarzi, Salar; Moradi, Mohammadreza; Abedi, Ahmad
2018-06-01
The present study aimed to develop the thinking maps training package and compare its training effect with the thinking maps method on the reading performance of second and fifth grade of elementary school male dyslexic students. For this mixed method exploratory study, from among the above mentioned grades' students in Isfahan, 90 students who met the inclusion criteria were selected by multistage sampling and randomly assigned into six experimental and control groups. The data were collected by reading and dyslexia test and Wechsler Intelligence Scale for Children-fourth edition. The results of covariance analysis indicated a significant difference between the reading performance of the experimental (thinking maps training package and thinking maps method groups) and control groups ([Formula: see text]). Moreover, there were significant differences between the thinking maps training package group and thinking maps method group in some of the subtests ([Formula: see text]). It can be concluded that thinking maps training package and the thinking maps method exert a positive influence on the reading performance of dyslexic students; therefore, thinking maps can be used as an effective training and treatment method.
Stuberg, W A; Colerick, V L; Blanke, D J; Bruce, W
1988-08-01
The purpose of this study was to compare a clinical gait analysis method using videography and temporal-distance measures with 16-mm cinematography in a gait analysis laboratory. Ten children with a diagnosis of cerebral palsy (means age = 8.8 +/- 2.7 years) and 9 healthy children (means age = 8.9 +/- 2.4 years) participated in the study. Stride length, walking velocity, and goniometric measurements of the hip, knee, and ankle were recorded using the two gait analysis methods. A multivariate analysis of variance was used to determine significant differences between the data collected using the two methods. Pearson product-moment correlation coefficients were determined to examine the relationship between the measurements recorded by the two methods. The consistency of performance of the subjects during walking was examined by intraclass correlation coefficients. No significant differences were found between the methods for the variables studied. Pearson product-moment correlation coefficients ranged from .79 to .95, and intraclass coefficients ranged from .89 to .97. The clinical gait analysis method was found to be a valid tool in comparison with 16-mm cinematography for the variables that were studied.
1972-01-01
The membrane methods described in Report 71 on the bacteriological examination of water supplies (Report, 1969) for the enumeration of coliform organisms and Escherichia coli in waters, together with a glutamate membrane method, were compared with the glutamate multiple tube method recommended in Report 71 and an incubation procedure similar to that used for membranes with the first 4 hr. at 30° C., and with MacConkey broth in multiple tubes. Although there were some differences between individual laboratories, the combined results from all participating laboratories showed that standard and extended membrane methods gave significantly higher results than the glutamate tube method for coliform organisms in both chlorinated and unchlorinated waters, but significantly lower results for Esch. coli with chlorinated waters and equivocal results with unchlorinated waters. Extended membranes gave higher results than glutamate tubes in larger proportions of samples than did standard membranes. Although transport membranes did not do so well as standard membrane methods, the results were usually in agreement with glutamate tubes except for Esch. coli in chlorinated waters. The glutamate membranes were unsatisfactory. Preliminary incubation of glutamate at 30° C. made little difference to the results. PMID:4567313
Comparison of two methods of MMPI-2 profile classification.
Munley, P H; Germain, J M
2000-10-01
The present study investigated the extent of agreement of the highest scale method and the best-fit method in matching MMPI-2 profiles to database code-type profiles and considered profile characteristics that may relate to agreement or disagreement of code-type matches by these two methods. A sample of 519 MMPI-2 profiles that had been classified into database profile code types by these two methods was studied. Resulting code-type matches were classified into three groups: identical (30%), similar (39%), and different (31%), and the profile characteristics of profile elevation, dispersion, and profile code-type definition were studied. Profile code-type definition was significantly different across the three groups with identical and similar match profile groups showing greater profile code-type definition and the different group consisting of profiles that were less well-defined.
Puzo, Quirino; Qin, Ping; Mehlum, Lars
2016-03-11
Suicide mortality and the rates by specific methods in a population may change over time in response to concurrent changes in relevant factors in society. This study aimed to identify significant changing points in method-specific suicide mortality from 1969 to 2012 in Norway. Data on suicide mortality by specific methods and by sex and age were retrieved from the Norwegian Cause-of-Death Register. Long-term trends in age-standardized rates of suicide mortality were analyzed by using joinpoint regression analysis. The most frequently used suicide method in the total population was hanging, followed by poisoning and firearms. Men chose suicide by firearms more often than women, whereas poisoning and drowning were more frequently used by women. The joinpoint analysis revealed that the overall trend of suicide mortality significantly changed twice along the period of 1969 to 2012 for both sexes. The male age-standardized suicide rate increased by 3.1% per year until 1989, and decreased by 1.2% per year between 1994 and 2012. Among females the long-term suicide rate increased by 4.0% per year until 1988, decreased by 5.5% through 1995, and then stabilized. Both sexes experienced an upward trend for suicide by hanging during the 44-year observation period, with a particularly significant increase in 15-24 year old males. The most distinct change among men was seen for firearms after 1988 with a significant decrease through 2012 of around 5% per year. For women, significant reductions since 1985-88 were observed for suicide by drowning and poisoning. The present study demonstrates different time trends for different suicide methods with significant reductions in suicide by firearms, drowning and poisoning after the peak in the suicide rate in the late 1980s. Suicide by means of hanging continuously increased, but did not fully compensate for the reduced use of other methods. This lends some support for the effectiveness of method-specific suicide preventive measures, such as restrictions to the access to firearms, which had been implemented in Norway during the relevant time period.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kost, S; Yu, N; Lin, S
2016-06-15
Purpose: To compare mean lung dose (MLD) estimates from 99mTc macroaggregated albumin (MAA) SPECT/CT using two published methodologies for patients treated with {sup 90}Y radioembolization for liver cancer. Methods: MLD was estimated retrospectively using two methodologies for 40 patients from SPECT/CT images of 99mTc-MAA administered prior to radioembolization. In these two methods, lung shunt fractions (LSFs) were calculated as the ratio of scanned lung activity to the activity in the entire scan volume or to the sum of activity in the lung and liver respectively. Misregistration of liver activity into the lungs during SPECT acquisition was overcome by excluding lungmore » counts within either 2 or 1.5 cm of the diaphragm apex respectively. Patient lung density was assumed to be 0.3 g/cm{sup 3} or derived from CT densitovolumetry respectively. Results from both approaches were compared to MLD determined by planar scintigraphy (PS). The effect of patient size on the difference between MLD from PS and SPECT/CT was also investigated. Results: Lung density from CT densitovolumetry is not different from the reference density (p = 0.68). The second method resulted in lung dose of an average 1.5 times larger lung dose compared to the first method; however the difference between the means of the two estimates was not significant (p = 0.07). Lung dose from both methods were statistically different from those estimated from 2D PS (p < 0.001). There was no correlation between patient size and the difference between MLD from PS and both SPECT/CT methods (r < 0.22, p > 0.17). Conclusion: There is no statistically significant difference between MLD estimated from the two techniques. Both methods are statistically different from conventional PS, with PS overestimating dose by a factor of three or larger. The difference between lung doses estimated from 2D planar or 3D SPECT/CT is not dependent on patient size.« less
Flow Cytometry of Human Primary Epidermal and Follicular Keratinocytes
Gragnani, Alfredo; Ipolito, Michelle Zampieri; Sobral, Christiane S; Brunialti, Milena Karina Coló; Salomão, Reinaldo; Ferreira, Lydia Masako
2008-01-01
Objective: The aim of this study was to characterize using flow cytometry cultured human primary keratinocytes isolated from the epidermis and hair follicles by different methods. Methods: Human keratinocytes derived from discarded fragments of total skin and scalp hair follicles from patients who underwent plastic surgery in the Plastic Surgery Division at UNIFESP were used. The epidermal keratinocytes were isolated by using 3 different methods: the standard method, upon exposure to trypsin for 30 minutes; the second, by treatment with dispase for 18 hours and with trypsin for 10 minutes; and the third, by treatment with dispase for 18 hours and with trypsin for 30 minutes. Follicular keratinocytes were isolated using the standard method. Results: On comparing the group treated with dispase for 18 hours and with trypsin for 10 minutes with the group treated with dispase for 18 hours and with trypsin for 30 minutes, it was observed that the first group presented the largest number of viable cells, the smallest number of cells in late apoptosis and necrosis with statistical significance, and no difference in apoptosis. When we compared the group treated with dispase for 18 hours and with trypsin for 10 minutes with the group treated with trypsin, the first group presented the largest number of viable cells, the smallest number of cells in apoptosis with statistical significance, and no difference in late apoptosis and necrosis. When we compared the results of the group treated with dispase for 18 hours and with trypsin for 10 minutes with the results for follical isolation, there was a statistical difference in apoptosis and viable cells. Conclusion: The isolation method of treatment with dispase for 18 hours and with trypsin for 10 minutes produced the largest number of viable cells and the smallest number of cells in apoptosis/necrosis. PMID:18350110
Evaluating the Impact of Library Instruction Methods on the Quality of Student Research.
ERIC Educational Resources Information Center
Ackerson, Linda G.; Young, Virgina E.
1994-01-01
A three-year study at the University of Alabama compared a traditional lecture method for teaching library research skills with a course-integrated, computer-enhanced approach by assessing each method's impact on the quality of bibliographies from engineering students' term papers. In four of the five semesters, no significant differences were…
A Comparison of Students' Performances Using Audio Only and Video Media Methods
ERIC Educational Resources Information Center
Sulaiman, Norazean; Muhammad, Ahmad Mazli; Ganapathy, Nurul Nadiah Dewi Faizul; Khairuddin, Zulaikha; Othman, Salwa
2017-01-01
Listening is a very crucial skill to be learnt in second language classroom because it is essential for the development of spoken language proficiency (Hamouda, 2013). The aim of this study is to investigate the significant differences in terms of students' performance when using traditional (audio-only) method and video media method. The data of…
Saad, Ahmed S; Abo-Talib, Nisreen F; El-Ghobashy, Mohamed R
2016-01-05
Different methods have been introduced to enhance selectivity of UV-spectrophotometry thus enabling accurate determination of co-formulated components, however mixtures whose components exhibit wide variation in absorptivities has been an obstacle against application of UV-spectrophotometry. The developed ratio difference at coabsorptive point method (RDC) represents a simple effective solution for the mentioned problem, where the additive property of light absorbance enabled the consideration of the two components as multiples of the lower absorptivity component at certain wavelength (coabsorptive point), at which their total concentration multiples could be determined, whereas the other component was selectively determined by applying the ratio difference method in a single step. Mixture of perindopril arginine (PA) and amlodipine besylate (AM) figures that problem, where the low absorptivity of PA relative to AM hinders selective spectrophotometric determination of PA. The developed method successfully determined both components in the overlapped region of their spectra with accuracy 99.39±1.60 and 100.51±1.21, for PA and AM, respectively. The method was validated as per the USP guidelines and showed no significant difference upon statistical comparison with reported chromatographic method. Copyright © 2015 Elsevier B.V. All rights reserved.
Olbrich, Marcus; Rieger, Melanie; Reinert, Siegmar; Alexander, Dorothea
2012-01-01
Human jaw periosteum tissue contains osteoprogenitors that have potential for tissue engineering applications in oral and maxillofacial surgeries. To isolate osteoprogenitor cells from heterogeneous cell populations, we used the specific mesenchymal stem cell antigen-1 (MSCA-1) antibody and compared two magnetic separation methods. We analyzed the obtained MSCA-1(+) and MSCA-1(-) fractions in terms of purity, yield of positive/negative cells and proliferative and mineralization potentials. The analysis of cell viability after separation revealed that the EasySep method yielded higher viability rates, whereas the flow cytometry results showed a higher purity for the MACS-separated cell fractions. The mineralization capacity of the osteogenic induced MSCA-1(+) cells compared with the MSCA-1(-) controls using MACS was 5-fold higher, whereas the same comparison after EasySep showed no significant differences between both fractions. By analyzing cell proliferation, we detected a significant difference between the proliferative potential of the osteogenic cells versus untreated cells after the MACS and EasySep separations. The differentiated cells after MACS separation adjusted their proliferative capacity, whereas the EasySep-separated cells failed to do so. The protein expression analysis showed small differences between the two separation methods. Our findings suggest that MACS is a more suitable separation method to isolate osteoprogenitors from the entire jaw periosteal cell population.
NASA Astrophysics Data System (ADS)
Salem, Hesham; Lotfy, Hayam M.; Hassan, Nagiba Y.; El-Zeiny, Mohamed B.; Saleh, Sarah S.
2015-01-01
This work represents a comparative study of different aspects of manipulating ratio spectra, which are: double divisor ratio spectra derivative (DR-DD), area under curve of derivative ratio (DR-AUC) and its novel approach, namely area under the curve correction method (AUCCM) applied for overlapped spectra; successive derivative of ratio spectra (SDR) and continuous wavelet transform (CWT) methods. The proposed methods represent different aspects of manipulating ratio spectra of the ternary mixture of Ofloxacin (OFX), Prednisolone acetate (PA) and Tetryzoline HCl (TZH) combined in eye drops in the presence of benzalkonium chloride as a preservative. The proposed methods were checked using laboratory-prepared mixtures and were successfully applied for the analysis of pharmaceutical formulation containing the cited drugs. The proposed methods were validated according to the ICH guidelines. A comparative study was conducted between those methods regarding simplicity, limitation and sensitivity. The obtained results were statistically compared with those obtained from the reported HPLC method, showing no significant difference with respect to accuracy and precision.
Salem, Hesham; Lotfy, Hayam M; Hassan, Nagiba Y; El-Zeiny, Mohamed B; Saleh, Sarah S
2015-01-25
This work represents a comparative study of different aspects of manipulating ratio spectra, which are: double divisor ratio spectra derivative (DR-DD), area under curve of derivative ratio (DR-AUC) and its novel approach, namely area under the curve correction method (AUCCM) applied for overlapped spectra; successive derivative of ratio spectra (SDR) and continuous wavelet transform (CWT) methods. The proposed methods represent different aspects of manipulating ratio spectra of the ternary mixture of Ofloxacin (OFX), Prednisolone acetate (PA) and Tetryzoline HCl (TZH) combined in eye drops in the presence of benzalkonium chloride as a preservative. The proposed methods were checked using laboratory-prepared mixtures and were successfully applied for the analysis of pharmaceutical formulation containing the cited drugs. The proposed methods were validated according to the ICH guidelines. A comparative study was conducted between those methods regarding simplicity, limitation and sensitivity. The obtained results were statistically compared with those obtained from the reported HPLC method, showing no significant difference with respect to accuracy and precision. Copyright © 2014 Elsevier B.V. All rights reserved.
P-Value Club: Teaching Significance Level on the Dance Floor
ERIC Educational Resources Information Center
Gray, Jennifer
2010-01-01
Courses: Beginning research methods and statistics courses, as well as advanced communication courses that require reading research articles and completing research projects involving statistics. Objective: Students will understand the difference between significant and nonsignificant statistical results based on p-value.
Joy, Stacey R; Bartelt-Hunt, Shannon L; Snow, Daniel D; Gilley, John E; Woodbury, Bryan L; Parker, David B; Marx, David B; Li, Xu
2013-01-01
Due to the use of antimicrobials in livestock production, residual antimicrobials and antimicrobial resistance genes (ARGs) could enter the environment following the land application of animal wastes and could further contaminate surface and groundwater. The objective of this study was to determine the effect of various manure land application methods on the fate and transport of antimicrobials and ARGs in soil and runoff following land application of swine manure slurry. Swine manure slurries were obtained from facilities housing pigs that were fed chlortetracyline, tylosin or bacitracin and were land applied via broadcast, incorporation, and injection methods. Three rainfall simulation tests were then performed on amended and control plots. Results show that land application methods had no statistically significant effect on the aqueous concentrations of antimicrobials in runoff. However, among the three application methods tested broadcast resulted in the highest total mass loading of antimicrobials in runoff from the three rainfall simulation tests. The aqueous concentrations of chlortetracyline and tylosin in runoff decreased in consecutive rainfall events, although the trend was only statistically significant for tylosin. For ARGs, broadcast resulted in significantly higher erm genes in runoff than did incorporation and injection methods. In soil, the effects of land application methods on the fate of antimicrobials in top soil were compound specific. No clear trend was observed in the ARG levels in soil, likely because different host cells may respond differently to the soil environments created by various land application methods.
Timing and technique impact the effectiveness of road-based, mobile acoustic surveys of bats.
D'Acunto, Laura E; Pauli, Benjamin P; Moy, Mikko; Johnson, Kiara; Abu-Omar, Jasmine; Zollner, Patrick A
2018-03-01
Mobile acoustic surveys are a common method of surveying bat communities. However, there is a paucity of empirical studies exploring different methods for conducting mobile road surveys of bats. During 2013, we conducted acoustic mobile surveys on three routes in north-central Indiana, U.S.A., using (1) a standard road survey, (2) a road survey where the vehicle stopped for 1 min at every half mile of the survey route (called a "start-stop method"), and (3) a road survey with an individual using a bicycle. Linear mixed models with multiple comparison procedures revealed that when all bat passes were analyzed, using a bike to conduct mobile surveys detected significantly more bat passes per unit time compared to other methods. However, incorporating genus-level comparisons revealed no advantage to using a bike over vehicle-based methods. We also found that survey method had a significant effect when analyses were limited to those bat passes that could be identified to genus, with the start-stop method generally detecting more identifiable passes than the standard protocol or bike survey. Additionally, we found that significantly more identifiable bat passes (particularly those of the Eptesicus and Lasiurus genera) were detected in surveys conducted immediately following sunset. As governing agencies, particularly in North America, implement vehicle-based bat monitoring programs, it is important for researchers to understand how variations on protocols influence the inference that can be gained from different monitoring schemes.
Zeng, Rui; Xiang, Lian-Rui; Zeng, Jing; Zuo, Chuan
2017-01-01
We aimed to introduce team-based learning (TBL) as one of the teaching methods for diagnostics and to compare its teaching effectiveness with that of the traditional teaching methods. We conducted a randomized controlled trial on diagnostics teaching involving 111 third-year medical undergraduates, using TBL as the experimental intervention, compared with lecture-based learning as the control, for teaching the two topics of symptomatology. Individual Readiness Assurance Test (IRAT)-baseline and Group Readiness Assurance Test (GRAT) were performed in members of each TBL subgroup. The scores in Individual Terminal Test 1 (ITT1) immediately after class and Individual Terminal Test 2 (ITT2) 1 week later were compared between the two groups. The questionnaire and interview were also implemented to survey the attitude of students and teachers toward TBL. There was no significant difference between the two groups in ITT1 (19.85±4.20 vs 19.70±4.61), while the score of the TBL group was significantly higher than that of the control group in ITT2 (19.15±3.93 vs 17.46±4.65). In the TBL group, the scores of the two terminal tests after the teaching intervention were significantly higher than the baseline test score of individuals. IRAT-baseline, ITT1, and ITT2 scores of students at different academic levels in the TBL teaching exhibited significant differences, but the ITT1-IRAT-baseline and ITT2-IRAT-baseline indicated no significant differences among the three subgroups. Our TBL in symptomatology approach was highly accepted by students in the improvement of interest and self-directed learning and resulted in an increase in knowledge acquirements, which significantly improved short-term test scores compared with lecture-based learning. TBL is regarded as an effective teaching method worthy of promoting.
Comparing 3D foot scanning with conventional measurement methods.
Lee, Yu-Chi; Lin, Gloria; Wang, Mao-Jiun J
2014-01-01
Foot dimension information on different user groups is important for footwear design and clinical applications. Foot dimension data collected using different measurement methods presents accuracy problems. This study compared the precision and accuracy of the 3D foot scanning method with conventional foot dimension measurement methods including the digital caliper, ink footprint and digital footprint. Six commonly used foot dimensions, i.e. foot length, ball of foot length, outside ball of foot length, foot breadth diagonal, foot breadth horizontal and heel breadth were measured from 130 males and females using four foot measurement methods. Two-way ANOVA was performed to evaluate the sex and method effect on the measured foot dimensions. In addition, the mean absolute difference values and intra-class correlation coefficients (ICCs) were used for precision and accuracy evaluation. The results were also compared with the ISO 20685 criteria. The participant's sex and the measurement method were found (p < 0.05) to exert significant effects on the measured six foot dimensions. The precision of the 3D scanning measurement method with mean absolute difference values between 0.73 to 1.50 mm showed the best performance among the four measurement methods. The 3D scanning measurements showed better measurement accuracy performance than the other methods (mean absolute difference was 0.6 to 4.3 mm), except for measuring outside ball of foot length and foot breadth horizontal. The ICCs for all six foot dimension measurements among the four measurement methods were within the 0.61 to 0.98 range. Overall, the 3D foot scanner is recommended for collecting foot anthropometric data because it has relatively higher precision, accuracy and robustness. This finding suggests that when comparing foot anthropometric data among different references, it is important to consider the differences caused by the different measurement methods.
Protein detection through different platforms of immuno-loop-mediated isothermal amplification
NASA Astrophysics Data System (ADS)
Pourhassan-Moghaddam, Mohammad; Rahmati-Yamchi, Mohammad; Akbarzadeh, Abolfazl; Daraee, Hadis; Nejati-Koshki, Kazem; Hanifehpour, Younes; Joo, Sang Woo
2013-11-01
Different immunoassay-based methods have been devised to detect protein targets. These methods have some challenges that make them inefficient for assaying ultra-low-amounted proteins. ELISA, iPCR, iRCA, and iNASBA are the common immunoassay-based methods of protein detection, each of which has specific and common technical challenges making it necessary to introduce a novel method in order to avoid their problems for detection of target proteins. Here we propose a new method nominated as `immuno-loop-mediated isothermal amplification' or `iLAMP'. This new method is free from the problems of the previous methods and has significant advantages over them. In this paper we also offer various configurations in order to improve the applicability of this method in real-world sample analyses. Important potential applications of this method are stated as well.
Joe, Paula S; Ito, Yasushi; Shih, Alan M; Oestenstad, Riedar K; Lungu, Claudiu T
2012-01-01
This study was designed to determine if three-dimensional (3D) laser scanning techniques could be used to collect accurate anthropometric measurements, compared with traditional methods. The use of an alternative 3D method would allow for quick collection of data that could be used to change the parameters used for facepiece design, improving fit and protection for a wider variety of faces. In our study, 10 facial dimensions were collected using both the traditional calipers and tape method and a Konica-Minolta Vivid9i laser scanner. Scans were combined using RapidForm XOR software to create a single complete facial geometry of the subject as a triangulated surface with an associated texture image from which to obtain measurements. A paired t-test was performed on subject means in each measurement by method. Nine subjects were used in this study: five males (one African-American and four Caucasian females) and four females displaying a range of facial dimensions. Five measurements showed significant differences (p<0.05), with most accounted for by subject movements or amended by scanning technique modifications. Laser scanning measurements showed high precision and accuracy when compared with traditional methods. Significant differences found can be very small changes in measurements and are unlikely to present a practical difference. The laser scanning technique demonstrated reliable and quick anthropometric data collection for use in future projects in redesigning respirators.
Amano, Shiro; Honda, Norihiko; Amano, Yuki; Yamagami, Satoru; Miyai, Takashi; Samejima, Tomokazu; Ogata, Miyuki; Miyata, Kazunori
2006-06-01
To compare central corneal thickness measurements and their reproducibility when taken by a rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit corneal topography/pachymetry. Experimental study. Seventy-four eyes of 64 subjects without ocular abnormalities other than cataract. Corneal thickness measurements were compared among the 3 methods in 54 eyes of 54 subjects. Two sets of measurements were repeated by a single examiner for each pachymetry in another 10 eyes of 5 subjects, and the intraexaminer repeatability was assessed as the absolute difference of the first and second measurements. Two experienced examiners took one measurement for each pachymetry in another 10 eyes of 5 subjects, and the interexaminer reproducibility was assessed as the absolute difference of the 2 measurements of the first and second examiners. Central corneal thickness measurements by the 3 methods, absolute difference of the first and second measurements by a single examiner, absolute difference of the 2 measurements by 2 examiners, and relative amount of variation. The average measurements of central corneal thickness by a rotating Scheimpflug camera, scanning-slit topography, and ultrasonic pachymetry were 538+/-31.3 microm, 541+/-40.7 microm, and 545+/-31.3 microm, respectively. There were no statistically significant differences in the measurement results among the 3 methods (P = 0.569, repeated-measures analysis of variance). There was a significant linear correlation between the rotating Scheimpflug camera and ultrasonic pachymetry (r = 0.908, P<0.0001), rotating Scheimpflug camera and scanning-slit topography (r = 0.930, P<0.0001), and ultrasonic pachymetry and scanning-slit topography (r = 0.887, P<0.0001). Ultrasonic pachymetry had the smallest intraexaminer variability, and scanning-slit topography had the largest intraexaminer variability among the 3 methods. There were similar variations in interexaminer reproducibility among the 3 methods. Mean corneal thicknesses were comparable among rotating Scheimpflug camera, ultrasonic pachymetry, and scanning-slit topography with the acoustic equivalent correction factor. The measurements of the 3 instruments had significant linear correlations with one another, and all methods had highly satisfactory measurement repeatability.
A comparison of VRML and animation of rotation for teaching 3-dimensional crystal lattice structures
NASA Astrophysics Data System (ADS)
Sauls, Barbara Lynn
Chemistry students often have difficulty visualizing abstract concepts of molecules and atoms, which may lead to misconceptions. The three-dimensionality of these structures presents a challenge to educators. Typical methods of teaching include text with two-dimensional graphics and structural models. Improved methods to allow visualization of 3D structures may improve learning of these concepts. This research compared the use of Virtual Reality Modeling Language (VRML) and animation of rotation for teaching three-dimensional structures. VRML allows full control of objects by altering angle, size, rotation, and provides the ability to zoom into and through objects. Animations may only be stopped, restarted and replayed. A web-based lesson teaching basic concepts of crystals, which requires comprehension of their three-dimensional structure was given to 100 freshmen chemistry students. Students were stratified by gender then randomly to one of two lessons, which were identical except for the multimedia method used to show the lattices and unit cells. One method required exploration of the structures using VRML, the other provided animations of the same structures rotating. The students worked through an examination as the lesson progressed. A Welch t' test was used to compare differences between groups. No significant difference in mean achievement was found between the two methods, between genders, or within gender. There was no significant difference in mean total SAT in the animation and VRML group. Total time on task had no significant difference nor did enjoyment of the lesson. Students, however, spent 14% less time maneuvering VRML structures than viewing the animations of rotation. Neither method proved superior for presenting three-dimensional information. The students spent less time maneuvering the VRML structures with no difference in mean score so the use of VRML may be more efficient. The investigator noted some manipulation difficulties using VRML to rotate structures. Some students had difficulty obtaining the correct angle required to properly interpret spatial relationships. This led to frustration and caused some students to quit trying before they could answer questions fully. Even though there were some difficulties, outcomes were not affected. Higher scores, however, may have been achieved had the students been proficient in VRML maneuvering.
NASA Astrophysics Data System (ADS)
Moustafa, Azza A.; Hegazy, Maha A.; Mohamed, Dalia; Ali, Omnia
2016-02-01
A novel approach for the resolution and quantitation of severely overlapped quaternary mixture of carbinoxamine maleate (CAR), pholcodine (PHL), ephedrine hydrochloride (EPH) and sunset yellow (SUN) in syrup was demonstrated utilizing different spectrophotometric assisted multivariate calibration methods. The applied methods have used different processing and pre-processing algorithms. The proposed methods were partial least squares (PLS), concentration residuals augmented classical least squares (CRACLS), and a novel method; continuous wavelet transforms coupled with partial least squares (CWT-PLS). These methods were applied to a training set in the concentration ranges of 40-100 μg/mL, 40-160 μg/mL, 100-500 μg/mL and 8-24 μg/mL for the four components, respectively. The utilized methods have not required any preliminary separation step or chemical pretreatment. The validity of the methods was evaluated by an external validation set. The selectivity of the developed methods was demonstrated by analyzing the drugs in their combined pharmaceutical formulation without any interference from additives. The obtained results were statistically compared with the official and reported methods where no significant difference was observed regarding both accuracy and precision.
A COMPARISON OF TEACHING METHODS BUILDING CULTURAL COMPETENCY INFORMED BY CONTACT THEORY.
Stough-Hunter, Anjel; Guinan, Jill; Hart, Julie P
2016-01-01
This study examines students' levels of cultural competency before and after taking three different semester-long courses dealing with diversity and cultural competence with each course representing a different teaching methodology. A new 20-item survey, designed for students across disciplines, was used to measure cultural competency among 226 students from the fall of2012 to the spring of2 015. Differences were examined between scores before and after taking each class, as well as differences between classes. There were significant improvements in all three groups, and a significant difference between two of the three classes in the improvement of scores.
A meta-analysis of in vitro antibiotic synergy against Acinetobacter baumannii.
March, Gabriel A; Bratos, Miguel A
2015-12-01
The aim of the work was to describe the different in vitro models for testing synergism of antibiotics and gather the results of antibiotic synergy against multidrug-resistant Acinetobacter baumannii (MDR-Ab). The different original articles were obtained from different web sites. In order to compare the results obtained by the different methods for synergy testing, the Pearson chi-square and the Fischer tests were used. Moreover, non-parametric chi-square test was used in order to compare the frequency distribution in each analysed manuscript. In the current meta-analysis 24 manuscripts, which encompassed 2016 tests of in vitro synergism of different antimicrobials against MDR-Ab, were revised. Checkerboard synergy testing was used in 11 studies, which encompasses 1086 tests (53.9%); time-kill assays were applied in 12 studies, which encompass 359 tests (17.8%); gradient diffusion methods were used in seven studies, encompassing 293 tests (14.5%). And, finally, time-kill plus checkerboard were applied in two studies, encompassing 278 tests (13.8%). By comparing these data, checkerboard and time-kill methods were significantly more used than gradient diffusion methods (p<0.005). Regarding synergy rates obtained on the basis of the applied method, checkerboard provided 227 tests (20.9%) with a synergistic effect; time-kill assays yielded 222 tests (61.8%) with a synergistic effect; gradient diffusion methods only provided 29 tests (9.9%) with a synergistic effect; and, finally, time-kill plus checkerboard yielded just 15 tests (5.4%) with a synergistic effect. When comparing these percentages, synergy rates reported by time-kill methods were significantly higher than that obtained by checkerboard and gradient diffusion methods (p<0.005). On the basis of the revised data, the combinations of a bactericidal antibiotic plus Tigecycline, Vancomycin or Teicoplanin are not recommended. The best combinations of antibiotics are those which include bactericidal antibiotics such as Carbapenems, Fosfomycin, Amikacin, Polymyxins, Rifampicin and Ampicillin/Sulbactam. Copyright © 2015. Published by Elsevier B.V.
Kanashiro, Lylian K; Robles-Ruíz, Julissa J; Ciamponi, Ana L; Medeiros, Igor S; Tortamano, André; Paiva, João B
2014-09-01
To determine the influence on shear bond strength and bond failure location of four cleaning methods for orthodontic bracket custom bases. In vitro laboratory study. Eighty bovine teeth were divided at random into four groups. The bracket custom bases were cleaned with different methods: group 1 with methyl methacrylate monomer, group 2 with acetone, group 3 with 50 μm aluminium oxide particles and group 4 with detergent. The brackets were indirectly bonded onto the teeth with the Sondhi Rapid-Set self-curing adhesive. The maximum required shear bond strength to debond the brackets was recorded. The bond failure location was evaluated using the Adhesive Remnant Index (ARI). One-way analysis of variance (ANOVA) analysis (P<0·05) was used to detect significant differences in the bond strength. Kaplan-Meier survival plots and log-rank test were done to compare the survival distribution between the groups. The Kruskal-Wallis test (P<0·05) was used to evaluate the differences in the ARI scores. The mean bond strengths in groups 1, 2, 3 and 4 were 23·7±5·0, 25·3±5·1, 25·6±3·7 and 25·7±4·2 MPa, respectively. There were no significant statistically differences in either the bond strength or the ARI score between the groups. The four custom base-cleaning methods presented the same efficiencies on indirect bond of the brackets; thus, practitioners can choose the method that works best for them. © 2014 British Orthodontic Society.
2012-01-01
Background From the viewpoint of human physiological adaptability, we previously investigated seasonal variation in the amount of unabsorbed dietary carbohydrates from the intestine after breakfast in Japanese, Polish and Thai participants. In this investigation we found that there were significant seasonal variations in the amount of unabsorbed dietary carbohydrates in Japanese and Polish participants, while we could not find significant seasonal variation in Thai participants. These facts prompted us to examine seasonal variations in the respiratory quotient after an overnight fast (an indicator of the ratio of carbohydrate and fat oxidized after the last meal) with female university students living in Osaka (Japan), Poznan (Poland) and Chiang Mai (Thailand). Methods We enrolled 30, 33 and 32 paid participants in Japan, Poland and Thailand, respectively, and measurements were taken over the course of one full year. Fasting respiratory quotient was measured with the participants in their postabsorptive state (after 12 hours or more fasting before respiratory quotient measurement). Respiratory quotient measurements were carried out by means of indirect calorimetry using the mixing chamber method. The percent body fat was measured using an electric bioelectrical impedance analysis scale. Food intake of the participants in Osaka and Poznan were carried out by the Food Frequency Questionnaire method. Results There were different seasonal variations in the fasting respiratory quotient values in the three different populations; with a significant seasonal variation in the fasting respiratory quotient values in Japanese participants, while those in Polish and Thai participants were non-significant. We found that there were significant seasonal changes in the percent body fat in the three populations but we could not find any significant correlation between the fasting respiratory quotient values and the percent body fat. Conclusions There were different seasonal variations in the fasting respiratory quotient values in the three different populations. There were significant seasonal changes in the percent body fat in the three populations but no significant correlation between the fasting respiratory quotient values and the percent body fat. PMID:22738323
Gritzfeld, Jenna F; Roberts, Paul; Roche, Lorna; El Batrawy, Sherouk; Gordon, Stephen B
2011-04-13
Nasopharyngeal carriage of potential pathogens is important as it is both the major source of transmission and the prerequisite of invasive disease. New methods for detecting carriage could improve comfort, accuracy and laboratory utility. The aims of this study were to compare the sensitivities of a nasopharyngeal swab (NPS) and a nasal wash (NW) in detecting potential respiratory pathogens in healthy adults using microbiological culture and PCR. Healthy volunteers attended for nasal washing and brushing of the posterior nasopharynx. Conventional and real-time PCR were used to detect pneumococcus and meningococcus. Statistical differences between the two nasal sampling methods were determined using a nonparametric Mann-Whitney U test; differences between culture and PCR methods were determined using the McNemar test.Nasal washing was more comfortable for volunteers than swabbing (n = 24). In detection by culture, the NW was significantly more likely to detect pathogens than the NPS (p < 0.00001). Overall, there was a low carriage rate of pathogens in this sample; no significant difference was seen in the detection of bacteria between culture and PCR methods. Nasal washing and PCR may provide effective alternatives to nasopharyngeal swabbing and classical microbiology, respectively.
NASA Astrophysics Data System (ADS)
Borrazzo, Cristian; Galea, Nicola; Pacilio, Massimiliano; Altabella, Luisa; Preziosi, Enrico; Carnì, Marco; Ciolina, Federica; Vullo, Francesco; Francone, Marco; Catalano, Carlo; Carbone, Iacopo
2018-02-01
Dynamic contrast-enhanced cardiovascular magnetic resonance imaging can be used to quantitatively assess the myocardial blood flow (MBF), recovering the tissue impulse response function for the transit of a gadolinium bolus through the myocardium. Several deconvolution techniques are available, using various models for the impulse response. The method of choice may influence the results, producing differences that have not been deeply investigated yet. Three methods for quantifying myocardial perfusion have been compared: Fermi function modelling (FFM), the Tofts model (TM) and the gamma function model (GF), with the latter traditionally used in brain perfusion MRI. Thirty human subjects were studied at rest as well as under cold pressor test stress (submerging hands in ice-cold water), and a single bolus of gadolinium weighing 0.1 ± 0.05 mmol kg-1 was injected. Perfusion estimate differences between the methods were analysed by paired comparisons with Student’s t-test, linear regression analysis, and Bland-Altman plots, as well as also using the two-way ANOVA, considering the MBF values of all patients grouped according to two categories: calculation method and rest/stress conditions. Perfusion estimates obtained by various methods in both rest and stress conditions were not significantly different, and were in good agreement with the literature. The results obtained during the first-pass transit time (20 s) yielded p-values in the range 0.20-0.28 for Student’s t-test, linear regression analysis slopes between 0.98-1.03, and R values between 0.92-1.01. From the Bland-Altman plots, the paired comparisons yielded a bias (and a 95% CI)—expressed as ml/min/g—for FFM versus TM, -0.01 (-0.20, 0.17) or 0.02 (-0.49, 0.52) at rest or under stress respectively, for FFM versus GF, -0.05 (-0.29, 0.20) or -0.07 (-0.55, 0.41) at rest or under stress, and for TM versus GF, -0.03 (-0.30, 0.24) or -0.09 (-0.43, 0.26) at rest or under stress. With the two-way ANOVA, the results were p = 0.20 for the method effect (not significant), p < 0.0001 for the rest/stress condition effect (highly significant, as expected), whereas no interaction resulted between the rest/stress condition and method (p = 0.70, not significant). Considering a wider time-frame (60 s), the estimates for both rest and stress conditions were 25%-30% higher (p in the range 0.016-0.025) than those obtained in the 20 s time-frame. MBF estimates obtained by various methods under rest/stress conditions were not significantly different in the first-pass transit time, encouraging quantitative perfusion estimates in DCE-CMRI with the used methods.
Comparative study of two commercially pure titanium casting methods
RODRIGUES, Renata Cristina Silveira; FARIA, Adriana Claudia Lapria; ORSI, Iara Augusta; de MATTOS, Maria da Gloria Chiarello; MACEDO, Ana Paula; RIBEIRO, Ricardo Faria
2010-01-01
The interest in using titanium to fabricate removable partial denture (RPD) frameworks has increased, but there are few studies evaluating the effects of casting methods on clasp behavior. Objective This study compared the occurrence of porosities and the retentive force of commercially pure titanium (CP Ti) and cobalt-chromium (Co-Cr) removable partial denture circumferential clasps cast by induction/centrifugation and plasma/vacuum-pressure. Material and Methods 72 frameworks were cast from CP Ti (n=36) and Co-Cr alloy (n=36; control group). For each material, 18 frameworks were casted by electromagnetic induction and injected by centrifugation, whereas the other 18 were casted by plasma and injected by vacuum-pressure. For each casting method, three subgroups (n=6) were formed: 0.25 mm, 0.50 mm, and 0.75 mm undercuts. The specimens were radiographed and subjected to an insertion/removal test simulating 5 years of framework use. Data were analyzed by ANOVA and Tukey's to compare materials and cast methods (α=0.05). Results Three of 18 specimens of the induction/centrifugation group and 9 of 18 specimens of plasma/vacuum-pressure cast presented porosities, but only 1 and 7 specimens, respectively, were rejected for simulation test. For Co-Cr alloy, no defects were found. Comparing the casting methods, statistically significant differences (p<0.05) were observed only for the Co-Cr alloy with 0.25 mm and 0.50 mm undercuts. Significant differences were found for the 0.25 mm and 0.75 mm undercuts dependent on the material used. For the 0.50 mm undercut, significant differences were found when the materials were induction casted. Conclusion Although both casting methods produced satisfactory CP Ti RPD frameworks, the occurrence of porosities was greater in the plasma/vacuum-pressure than in the induction/centrifugation method, the latter resulting in higher clasp rigidity, generating higher retention force values. PMID:21085805
Comparison of evaporation computation methods, Pretty Lake, Lagrange County, northeastern Indiana
Ficke, John F.
1972-01-01
The different methods, although poor, agree that evaporation when there is ice cover is generally small (less than 0.1 cm day" 1 ), but the evaporation rates during the few days just before freezeup or just after ice breakup are significant
Linking Neuroscience and Psychoanalysis.
ERIC Educational Resources Information Center
Habicht, Manuela H.
This review discusses the relationship between neuroscience and psychoanalysis and introduces a new scientific method called neuro-psychoanalysis, a combination of the two phenomena. A significant difference between the two is that psychoanalysis has not evolved scientifically since it has not developed objective methods for testing ideas that it…
McNamara, P J; Sharief, N
2001-09-01
Near-patient blood glucose monitoring is an essential component of neonatal intensive care but the analysers currently used are unreliable and inaccurate. The aim of this study was to compare a new glucose electrode-based analyser (EML 105) and a non-wipe reflectance photometry method (Advantage) as opposed to a recognized laboratory reference method (Hexokinase). We also investigated the effect of sample route and haematocrit on the accuracy of the glucose readings obtained by each method of analysis. Whole blood glucose concentrations ranging from 0 to 3.5 mmol/l were carefully prepared in a laboratory setting and blood samples from each respective solution were then measured by EML 105 and Advantage analysers. The results obtained were then compared with the corresponding plasma glucose reading obtained by the Hexokinase method, using linear regression analysis. An in vivo study was subsequently performed on 103 neonates, over a 1-y period, using capillary and venous whole blood samples. Whole blood glucose concentration was estimated from each sample using both analysers and compared with the corresponding plasma glucose concentration estimated by the Hexokinase method. Venous blood was centrifuged and haematocrit was estimated using standardized curves. The effect of haematocrit on the agreement between whole blood and plasma glucose was investigated, estimating the degree of correlation on a scatterplot of the results and linear regression analysis. Both the EML 105 and Hexokinase methods were highly accurate, in vitro, with small proportional biases of 2% and 5%, respectively. However, in vivo, both study analysers overestimated neonatal plasma glucose, ranging from at best 0.45 mmol/l (EML 105 venous) to 0.69 mmol/l (EML capillary). There was no significant difference in the agreement of capillary (GD = 0.12, 95% CI, [-0.32,0.08], p = 0.2) or venous samples (GD = 0.05, 95% CI. [0.09, 0.19], p = 0.49) with plasma glucose when analysed by either study method (GD = glucose difference between study analyser and reference method) However, the venous samples analysed by EML 105 estimated plasma glucose significantly better than capillary samples using the same method of analysis (GD = 0.24, 95% CI. [0.09,0.38], p < 0.01). The relationship between haematocrit and the resultant glucose differences was non-linear with correlation coefficients of r = -0.057 (EML 105 capillary), r = 0.145 (EML 105 venous), r = -0.127 (Advantage capillary) and r = -0.275 (Advantage venous). There was no significant difference in the effect of haematocrit on the performance of EML 105 versus Advantage, regardless of the sample route. Both EML 105 and Advantage overestimated plasma glucose, with no significant difference in the performance of either analyser, regardless of the route of analysis. Agreement with plasma glucose was better for venous samples but this was only statistically significant when EML 105 capillary and venous results were compared. Haematocrit is not a significant confounding factor towards the performance of either EML 105 or Advantage in neonates, regardless of the route of sampling. The margin of overestimation of blood glucose prohibits the recommendation of both EML 105 and Advantage for routine neonatal glucose screening. The consequences include failure accurately to diagnose hypoglycaemia and delays in the instigation of therapeutic measures, both of which may potentially result in an adverse, long-term, neurodevelopmental outcome.
Digital versus conventional techniques for pattern fabrication of implant-supported frameworks
Alikhasi, Marzieh; Rohanian, Ahmad; Ghodsi, Safoura; Kolde, Amin Mohammadpour
2018-01-01
Objective: The aim of this experimental study was to compare retention of frameworks cast from wax patterns fabricated by three different methods. Materials and Methods: Thirty-six implant analogs connected to one-piece abutments were divided randomly into three groups according to the wax pattern fabrication method (n = 12). Computer-aided design/computer-aided manufacturing (CAD/CAM) milling machine, three-dimensional printer, and conventional technique were used for fabrication of waxing patterns. All laboratory procedures were performed by an expert-reliable technician to eliminate intra-operator bias. The wax patterns were cast, finished, and seated on related abutment analogs. The number of adjustment times was recorded and analyzed by Kruskal–Wallis test. Frameworks were cemented on the corresponding analogs with zinc phosphate cement and tensile resistance test was used to measure retention value. Statistical Analysis Used: One-way analysis of variance (ANOVA) and post hoc Tukey tests were used for statistical analysis. Level of significance was set at P < 0.05. Results: The mean retentive values of 680.36 ± 21.93 N, 440.48 ± 85.98 N, and 407.23 ± 67.48 N were recorded for CAD/CAM, rapid prototyping, and conventional group, respectively. One-way ANOVA test revealed significant differences among the three groups (P < 0.001). The post hoc Tukey test showed significantly higher retention for CAD/CAM group (P < 0.001), while there was no significant difference between the two other groups (P = 0.54). CAD/CAM group required significantly more adjustments (P < 0.001). Conclusions: CAD/CAM-fabricated wax patterns showed significantly higher retention for implant-supported cement-retained frameworks; this could be a valuable help when there are limitations in the retention of single-unit implant restorations. PMID:29657528
A comparison of two central difference schemes for solving the Navier-Stokes equations
NASA Technical Reports Server (NTRS)
Maksymiuk, C. M.; Swanson, R. C.; Pulliam, T. H.
1990-01-01
Five viscous transonic airfoil cases were computed by two significantly different computational fluid dynamics codes: An explicit finite-volume algorithm with multigrid, and an implicit finite-difference approximate-factorization method with Eigenvector diagonalization. Both methods are described in detail, and their performance on the test cases is compared. The codes utilized the same grids, turbulence model, and computer to provide the truest test of the algorithms. The two approaches produce very similar results, which, for attached flows, also agree well with experimental results; however, the explicit code is considerably faster.
Baldwin, Margaret
2006-07-01
Tympanometry using 226 Hz, 678 Hz, and 1000 Hz probe tones was undertaken on two groups of babies, age 2 to 21 weeks. A group of 104 babies with normal ABR thresholds or TEOAEs were compared with a second group of 107 babies who had evidence of temporary conductive hearing loss based on the findings of a test battery, which included air and bone conduction ABR. The tympanograms were classified by Method 1, a simple visual classification system, and Method 2, adapted from a system described by Marchant et al (1986). The majority of tympanograms recorded in both groups using the 226 Hz probe tone were 'normal' Type A, with no significant difference in middle ear pressure or static admittance. However, both classification methods demonstrated significant differences between the two groups using the higher frequency probe tones, with Method 2 being the preferred system of classification. Tympanometry using 226 Hz is invalid below 21 weeks and 1000 Hz is the frequency of choice.
Coordinate alignment of combined measurement systems using a modified common points method
NASA Astrophysics Data System (ADS)
Zhao, G.; Zhang, P.; Xiao, W.
2018-03-01
The co-ordinate metrology has been extensively researched for its outstanding advantages in measurement range and accuracy. The alignment of different measurement systems is usually achieved by integrating local coordinates via common points before measurement. The alignment errors would accumulate and significantly reduce the global accuracy, thus need to be minimized. In this thesis, a modified common points method (MCPM) is proposed to combine different traceable system errors of the cooperating machines, and optimize the global accuracy by introducing mutual geometric constraints. The geometric constraints, obtained by measuring the common points in individual local coordinate systems, provide the possibility to reduce the local measuring uncertainty whereby enhance the global measuring certainty. A simulation system is developed in Matlab to analyze the feature of MCPM using the Monto-Carlo method. An exemplary setup is constructed to verify the feasibility and efficiency of the proposed method associated with laser tracker and indoor iGPS systems. Experimental results show that MCPM could significantly improve the alignment accuracy.
Effect of Temperature on Ultrasonic Signal Propagation for Extra Virgin Olive Oil Adulteration
NASA Astrophysics Data System (ADS)
Alias, N. A.; Hamid, S. B. Abdul; Sophian, A.
2017-11-01
Fraud cases involving adulteration of extra virgin olive oil has become significant nowadays due to increasing in cost of supply and highlight given the benefit of extra virgin olive oil for human consumption. This paper presents the effects of temperature variation on spectral formed utilising pulse-echo technique of ultrasound signal. Several methods had been introduced to characterize the adulteration of extra virgin olive oil with other fluid sample such as mass chromatography, standard method by ASTM (density test, distillation test and evaporation test) and mass spectrometer. Pulse-echo method of ultrasound being a non-destructive method to be used to analyse the sound wave signal captured by oscilloscope. In this paper, a non-destructive technique utilizing ultrasound to characterize extra virgin olive oil adulteration level will be presented. It can be observed that frequency spectrum of sample with different ratio and variation temperature shows significant percentages different from 30% up to 70% according to temperature variation thus possible to be used for sample characterization.
Effect of freezing method and frozen storage duration on lamb sensory quality.
Muela, E; Sañudo, C; Campo, M M; Medel, I; Beltrán, J A
2012-01-01
This study assessed the effect of three freezing methods with three frozen storage durations (1, 3, and 6 months) on the sensory quality of lamb. Methods were: air blast freezer, freezing tunnel+air blast freezer, and nitrogen chamber+air blast freezer. Meat was frozen after 48 h of ageing (0-4°C). Fresh meat (72 h ageing at 2-4°C) was used as control. Sensory analyses (trained panel and consumer tests) were performed on loin chops (Longissimus lumborum) after 24 h of thawing. Results from the trained panel test showed that freezing (method and/or storage duration) had no significant effect. Consumers found that freezing affected sensory quality. Cluster analysis for overall acceptability divided the population into four classes with different preference patterns, and none of them showed a significant preference for fresh meat. The small differences between fresh and thawed meat shown in this study should not give consumers concerns about buying frozen meat or consuming thawed meat. Copyright © 2011. Published by Elsevier Ltd.
Anand, Shruti; Tripathi, Siddhi; Chopra, Anubhav; Khaneja, Karan; Agarwal, Swatantra
2015-01-01
The purpose was to examine the existence of divine proportions among the Indian faces in Moradabad population. Totally, 100 patients (50 males; 50 females) aged 25-45 years were selected for the study. All facial photographs were analyzed based on the method of Ricketts assessing the divine proportions in vertical and transverse facial planes. Six horizontal and seven vertical ratios were determined, which were then compared with the phi ratio. The horizontal ratio results showed that three male and female ratios were not significantly different from each other (P > 0.05), and interchilion/nose width ratio was highly significant (P < 0.001). The horizontal mean ratios for females as well as males were highly significant from the phi ratio (P < 0.001) except for interchilion/interdacryon ratio, which was significant (P < 0.05) for females and not significant (P > 0.05) for males. The vertical ratio results showed that there was a highly significant difference (P < 0.001) for forehead height/stomion-soft menton ratio and no significant difference for two ratios between the mean ratios of males and females. All the vertical mean ratios for both the groups were highly significant (P < 0.001), except for the intereye-soft menton/intereye-stomion ratio, which was significant (P < 0.05) for female group and not significant (P > 0.05) for the male group. Although, the golden proportion is a prominent and recurring theme in esthetics, it should not be embraced as the only method by which human beauty is measured to the exclusion of others factors.
Hozo, Iztok; Tsalatsanis, Athanasios
2016-01-01
Abstract Rationale, aims, and objectives Decision curve analysis (DCA) is a widely used method for evaluating diagnostic tests and predictive models. It was developed based on expected utility theory (EUT) and has been reformulated using expected regret theory (ERG). Under certain circumstances, these 2 formulations yield different results. Here we describe these situations and explain the variation. Methods We compare the derivations of the EUT‐ and ERG‐based formulations of DCA for a typical medical decision problem: “treat none,” “treat all,” or “use model” to guide treatment. We illustrate the differences between the 2 formulations when applied to the following clinical question: at which probability of death we should refer a terminally ill patient to hospice? Results Both DCA formulations yielded identical but mirrored results when treatment effects are ignored; they generated significantly different results otherwise. Treatment effect has a significant effect on the results derived by EUT DCA and less so on ERG DCA. The elicitation of specific values for disutilities affected the results even more significantly in the context of EUT DCA, whereas no such elicitation was required within the ERG framework. Conclusion EUT and ERG DCA generate different results when treatment effects are taken into account. The magnitude of the difference depends on the effect of treatment and the disutilities associated with disease and treatment effects. This is important to realize as the current practice guidelines are uniformly based on EUT; the same recommendations can significantly differ if they are derived based on ERG framework. PMID:27981695
Hageman, W J; Arrindell, W A
1999-12-01
Based on a secondary analysis of the Jacobson and Truax [Jacobson, N.S. & Truax, P. (1991). a statistical approach to defining meaningful change in psychotherapy research. Journal of Consulting and Clinical Psychology, 59, 12-19.] data using both their own traditional approach and the refined method advanced by Hageman and Arrindell [Hageman, W.J.J.M., & Arrindell, W.A. (1999). Establishing clinically significant change: increment of precision and the distinction between individual and group level of analysis. Behaviour Research and Therapy, 37, 1169-1193], McGlinchey and Jacobson [McGlinchey, J. B., & Jacobson, N. S. (1999). Clinically significant but impractical? A response to Hageman and Arrindell. Behaviour Research and Therapy, 37, 1211-1217.] reported practically identical findings on reliable and clinically significant change across the two approaches. This led McGlinchey and Jacobson to conclude that there is little practical gain in utilizing the refined method over the traditional approach. Close inspection of the data used by McGlinchey and Jacobson however revealed a serious mistake with respect to the value of the standard error of measurement that was employed in their calculations. When the proper index value was utilised, further re-analysis by the present authors disclosed clear differences (i.e. different classifications of S's) across the two approaches. Importantly, these differences followed exactly the same pattern as depicted in Table 2 in Hageman and Arrindell (1999). The theoretical advantages of the refined method, i.e. enhanced precision, appropriate distinction between analysis at the individual and group levels, and maximal comparability of findings across studies, exceed those of the traditional method. Application of the refined method may be carried out within approximately half an hour, which not only supports its practical manageability, but also challenges the suggestion of McGlinchey and Jacobson (1999) that the relevant method would be too complex (impractical) for the average scientist. The reader is offered the opportunity of obtaining an SPSS setup in the form of an ASCII text file by means of which the relevant calculations can be carried out. The ways in which the valuable commentaries by Hsu [Hsu, L. M. (1999). A comparison of three methods of identifying reliable and clinically significant client changes: commentary on Hageman and Arrindell. Behaviour Research and Therapy, 37, 1195-1202.] and Speer [Speer, D. C. (1999). What is the role of two-wave designs in clinical research? Comment on Hageman and Arrindell. Behaviour Research and Therapy, 37, 1203-1210.) contribute to a better understanding of the technical/statistical backgrounds of the traditional and refined methods were also discussed.