Roles of three amino acids of capsid proteins in mink enteritis parvovirus replication.
Mao, Yaping; Su, Jun; Wang, Jigui; Zhang, Xiaomei; Hou, Qiang; Bian, Dawei; Liu, Weiquan
2016-08-15
Virulent mink enteritis parvovirus (MEV) strain MEV-LHV replicated to higher titers in feline F81 cells than attenuated strain MEV-L. Phylogenetic and sequence analyses of the VP2 gene of MEV-LHV, MEV-L and other strains in GenBank revealed two evolutionary branches separating virulent and attenuated strains. Three residues, 101, 232 and 411, differed between virulent and attenuated strains but were conserved within the two branches. Site-directed mutagenesis of the VP2 gene of infectious plasmids of attenuated strain MEV-L respectively replacing residues 101 Ile and 411 Ala with Thr and Glu of virulent strains (MEV-L I101T and MEV-L A411E) increased replication efficiency but still to lower levels than MEV-LHV. However, viruses with mutation of residue 232 (MEV-L I232V and MEV-L I101T/I232V/A411E) decreased viral transcription and replication levels. The three VP2 residues 101, 232 and 411, located on or near the capsid surface, played different roles in the infection processes of MEV. Copyright © 2016 Elsevier B.V. All rights reserved.
Drug and tobacco detection using neutron transmission/attenuation
NASA Astrophysics Data System (ADS)
Miller, Thomas G.
1994-10-01
A neutron transmission/attenuation spectrometer has been used to obtain the neutron attenuation signature of cocaine, heroin, hashish, methamphetamine, pipe tobacco and chewing tobacco. A pulsed `white neutron' source was created by bombarding a thick beryllium target with a 5 MeV pulsed deuteron beam. The neutron intensity was measured from about 0.75 MeV to about 4 MeV with the suitcase in and out of the neutron beam to determine the neutron attenuation. Experiments were performed for drugs and tobacco alone and when imbedded in an `average suitcase'. The experimentally determined neutron attenuation curves were used to determine the atomic ratios C/O, N/O, and H/C through the samples using measured neutron cross sections.
Mao, Yaping; Wang, Jigui; Hou, Qiang; Xi, Ji; Zhang, Xiaomei; Bian, Dawei; Yu, Yongle; Wang, Xi; Liu, Weiquan
2016-06-01
A virus isolated from mink showing clinical signs of enteritis was identified as a high virulent mink enteritis parvovirus (MEV) based on its biological characteristics in vivo and in vitro. Mink, challenged with this strain named MEV-LHV, exhibited severe pathological lesions as compared to those challenged with attenuated strain MEV-L. MEV-LHV also showed higher infection and replication efficiencies in vitro than MEV-L. Sequence of the complete genome of MEV-LHV was determined and analyzed in comparison with those in GenBank, which revealed that MEV-LHV shared high homology with virulent strain MEV SD12/01, whereas MEV-L was closely related to Abashiri and vaccine strain MEVB, and belonged to a different branch of the phylogenetic tree. The genomes of the two strains differed by insertions and deletions in their palindromic termini and specific unique mutations (especially VP2 300) in coding sequences which may be involved in viral replication and pathogenicity. The results of this study provide a better understanding of the biological and genomic characteristics of MEV and identify certain regions and sites that may be involved in viral replication and pathogenicity.
NASA Astrophysics Data System (ADS)
Zhang, L.; Jia, M. C.; Gong, J. J.; Xia, W. M.
2017-12-01
The mass attenuation coefficient of various Lead-Boron Polyethylene samples which can be used as the photon shielding materials in marine reactor, have been simulated using the MCNP-5 code, and compared with the theoretical values at the photon energy range 0.001MeV—20MeV. A good agreement has been observed. The variations of mass attenuation coefficient, linear attenuation coefficient and mean free path with photon energy between 0.001MeV to 100MeV have been plotted. The result shows that all the coefficients strongly depends on the photon energy, material atomic composition and density. The dose transmission factors for source Cesium-137 and Cobalt-60 have been worked out and their variations with the thickness of various sample materials have also been plotted. The variations show that with the increase of materials thickness the dose transmission factors decrease continuously. The results of this paper can provide some reference for the use of the high effective shielding material Lead-Boron Polyethyene.
Lifetime Measurement in the Yrast Band of 119I
NASA Astrophysics Data System (ADS)
Lobach, Yu. N.; Pasternak, A. A.; Srebrny, J.; Droste, Ch.; Hagemann, G. B.; Juutinen, S.; Morek, T.; Piiparinen, M.; Podsvirova, E. O.; Toermaenen, S.; Starosta, K.; Virtanen, A.; Wasilewski, A. A.
1999-05-01
The lifetime of levels in the yrast band of 119I were measured by DSAM and RDM using the 109Ag (13C,3n) reaction at E=54 MeV. The detailed description of data analysis including the stopping power determination and estimation of side feeding time is given. A modified method of RDM data analysis --- Recoil Distance Doppler Shape Attenuation (RDDSA) is used.
Effect of antimony-oxide on the shielding properties of some sodium-boro-silicate glasses.
Zoulfakar, A M; Abdel-Ghany, A M; Abou-Elnasr, T Z; Mostafa, A G; Salem, S M; El-Bahnaswy, H H
2017-09-01
Some sodium-silicate-boro-antimonate glasses having the molecular composition [(20) Na 2 O - (20) SiO 2 - (60-x) B 2 O 3 - (x) Sb 2 O 3 (where x takes the values 0, 5 … or 20)] have been prepared by the melt quenching method. The melting and annealing temperatures were 1500 and 650K respectively. The amorphous nature of the prepared samples was confirmed by using X-ray diffraction analysis. Both the experimental and empirical density and molar volume values showed gradual increase with increasing Sb 2 O 3 content. The empirical densities showed higher values than those obtained experimentally, while the empirical molar volume values appeared lower than those obtained experimentally, which confirm the amorphous nature and randomness character of the studied samples. The experimentally obtained shielding parameters were approximately coincident with those obtained theoretically by applying WinXCom program. At low gamma-ray energies (0.356 and 0.662MeV) Sb 2 O 3 has approximately no effect on the total Mass Attenuation Coefficient, while at high energies it acts to increase the total Mass Attenuation Coefficient gradually. The obtained Half Value Layer and Mean Free Path values showed gradual decrease as Sb 2 O 3 was gradually increased. Also, the Total Mass Attenuation Coefficient values obtained between about 0.8 and 3.0MeV gamma-ray energy showed a slight decrease, as gamma-ray photon energy increased. This may be due to the differences between the Attenuation Coefficients of both antimony and boron oxides at various gamma-ray photon energies. However, it can be stated that the addition of Sb 2 O 3 into sodium-boro-silicate glasses increases the gamma-ray Attenuation Coefficient and the best sample is that contains 20 mol% of Sb 2 O 3 , which is operating well at 0.356 and 0.662MeV gamma-ray. Copyright © 2017 Elsevier Ltd. All rights reserved.
X-Ray Attenuation Coefficients from 10 Kev to 100 Mev,
1957-04-30
is u&Ung"w APR n 4 1994 94-10025 0 Z1UNITED STATES DEPARTMENT OF COMMERCE NATIONAL BUREAU OF STANDARDS 94 .4 1 096 Data on Radiation Physics Graphs...OF COMMERCE • Sinclair Weeks, Secretary NATIONAL BUREAU OF STANDARDS , A. V. Astin, Dirvcew X-ray Attenuation Coefficients From 10 key to 100 Mev...Dit. ibtion I Availabiilty Codes Avai# and/or Dist Special National Bureau of Standards Circular 583 Issuw1 April 30, 1957 Fo e teSpr dt
EGRET observations of bursts at MeV energies
NASA Astrophysics Data System (ADS)
Catelli, J. R.; Dingus, B. L.; Schneid, E. J.
1998-05-01
We present preliminary results from the analysis of 16 bright bursts that have been observed by the EGRET NaI calorimeter, or TASC. Seven bursts have been imaged in the EGRET spark chamber above 30 MeV, but in most cases the TASC data gives the highest energy spectra available for these bursts. The TASC can obtain spectral and rate information for bursts well outside the field of view of the EGRET spark chambers, and is sensitive in the energy range from 1 to 200 MeV. The spectra for these bursts are mostly consistent with a simple power law with spectral index in the range from 1.7 to 3.7, with several of the brighter bursts showing emission past 100 MeV. No high energy cutoff has been observed. These high energy photons offer important clues to the physical processes involved at the origin of burst emission. For bursts at cosmological distances extremely high bulk Lorentz factors are implied by the presence of MeV and GeV photons which have not been attenuated by pair production with the lower energy photons from the source.
NASA Astrophysics Data System (ADS)
Langeveld, Willem G. J.
The most widely used technology for the non-intrusive active inspection of cargo containers and trucks is x-ray radiography at high energies (4-9 MeV). Technologies such as dual-energy imaging, spectroscopy, and statistical waveform analysis can be used to estimate the effective atomic number (Zeff) of the cargo from the x-ray transmission data, because the mass attenuation coefficient depends on energy as well as atomic number Z. The estimated effective atomic number, Zeff, of the cargo then leads to improved detection capability of contraband and threats, including special nuclear materials (SNM) and shielding. In this context, the exact meaning of effective atomic number (for mixtures and compounds) is generally not well-defined. Physics-based parameterizations of the mass attenuation coefficient have been given in the past, but usually for a limited low-energy range. Definitions of Zeff have been based, in part, on such parameterizations. Here, we give an improved parameterization at low energies (20-1000 keV) which leads to a well-defined Zeff. We then extend this parameterization up to energies relevant for cargo inspection (10 MeV), and examine what happens to the Zeff definition at these higher energies.
Mineral exploration and soil analysis using in situ neutron activation
Senftle, F.E.; Hoyte, A.F.
1966-01-01
A feasibility study has been made to operate by remote control an unshielded portable positive-ion accelerator type neutron source to induce activities in the ground or rock by "in situ" neutron irradiation. Selective activation techniques make it possible to detect some thirty or more elements by irradiating the ground for periods of a few minutes with either 3-MeV or 14-MeV neutrons. The depth of penetration of neutrons, the effect of water content of the soil on neutron moderation, gamma ray attenuation in the soil and other problems are considered. The analysis shows that, when exploring for most elements of economic interest, the reaction 2H(d,n)3He yielding ??? 3-MeV neutrons is most practical to produce a relatively uniform flux of neutrons of less than 1 keV to a depth of 19???-20???. Irradiation with high energy neutrons (??? 14 MeV) can also be used and may be better suited for certain problems. However, due to higher background and lower sensitivity for the heavy minerals, it is not a recommended neutron source for general exploration use. Preliminary experiments have been made which indicate that neutron activation in situ is feasible for a mineral exploration or qualititative soil analysis. ?? 1976.
Method for detecting moisture in soils using secondary cosmic radiation
Condreva, Kenneth
2003-12-16
Water content in a soil is determined by measuring the attenuation of secondary background cosmic radiation as this radiation propagates through a layer of soil and water. By measuring the attenuation of secondary cosmic radiation in the range of 5 MeV-15 MeV it is possible to obtain a relative measure of the water content in a soil layer above a suitable radiation detector and thus establish when and how much irrigation is needed. The electronic circuitry is designed so that a battery pack can be used to supply power.
NASA Astrophysics Data System (ADS)
Yusof, Mohd Fahmi Mohd; Hamid, Puteri Nor Khatijah Abd; Tajuddin, Abd Aziz; Abdullah, Reduan; Hashim, Rokiah; Bauk, Sabar; Isa, Norriza Mohd; Isa, Muhammad Jamal Md
2017-01-01
The effective atomic number of tannin-added Rhizophora spp. particleboards was determined based on elemental composition using Energy Dispersive X-ray Analysis (EDXA). The value of mass attenuation coefficients were measured using 137Cs and 60Co gamma energies. The attenuation properties of PDD curves and beam profile of tannin-added Rhizophora spp. particleboards were investigated using Gafchromic EBT2 film at 6 MV photon and 6 MeV electrons and compared to the value in water and solid water phantoms. The results showed that tannin-added Rhizophora spp. particleboards having effective atomic number close to the value of water. The mass attenuation coefficients were near to the value of water with χ2 values of 0.018 and 0.357 to 137Cs and 60Co gamma energies respectively. The PDD of tannin-added Rhizophora spp. particleboards at 6 MV photons showed good agreement within 3.21 and 5.91% to that in solid water phantoms and water respectively. The PDD at 6 MeV electrons showed a good agreement within 3.32 and 3.12% to that in solid water phantoms and water respectively. The depth of R50 and R90 in tannin-added Rhizophora spp. also showed a good agreement to that in water and solid water pahtoms. Lower surface dose was observed in tannin-added Rhizophora spp. particleboards at electron beams in comparison to solid water phantoms and water.
Attenuation and Refraction of an Electromagnetic Wave in an Electron Beam Generated Plasma
2001-02-01
100 keV and 1 MeV respectively. Plasma chemistry plays a critical role in determining the electron plasma density and dictates the beam format required to achieve a desired level of EM wave attenuation.
Absolute determination of copper and silver in ancient coins using 14 MeV neutrons
NASA Astrophysics Data System (ADS)
Chalouhi, Ch.; Hourani, E.; Loos, R.; Melki, S.
1982-09-01
A method for absolute determination of copper and silver in ancient coins is described. Activation analysis by 14 MeV neutrons is performed. In the experimental procedure emphasis is placed on corrections for neutrons and gamma attenuation. In the analytical procedure, a multi linear-regression calculation is used to separate different contributions to the 511 keV gamma peak. The precision in the absolute determination of Cu and Ag is better than 2% in recent coins of definite shapes, whereas it is a somewhat lower in ancient coins of irregular shapes. The method was applied to ancient coins provided by the Museum of the American University of Beirut. Overall consistency and suitability of the method were obtained.
Griffin, Diane E
2018-03-01
Measles remains an important cause of child morbidity and mortality worldwide despite the availability of a safe and efficacious vaccine. The current measles virus (MeV) vaccine was developed empirically by attenuation of wild-type (WT) MeV by in vitro passage in human and chicken cells and licensed in 1963. Additional passages led to further attenuation and the successful vaccine strains in widespread use today. Attenuation is associated with decreased replication in lymphoid tissue, but the molecular basis for this restriction has not been identified. The immune response is age dependent, inhibited by maternal antibody (Ab) and involves induction of both Ab and T cell responses that resemble the responses to WT MeV infection, but are lower in magnitude. Protective immunity is correlated with levels of neutralizing Ab, but the actual immunologic determinants of protection are not known. Because measles is highly transmissible, control requires high levels of population immunity. Delivery of the two doses of vaccine needed to achieve >90% immunity is accomplished by routine immunization of infants at 9-15 months of age followed by a second dose delivered before school entry or by periodic mass vaccination campaigns. Because delivery by injection creates hurdles to sustained high coverage, there are efforts to deliver MeV vaccine by inhalation. In addition, the safety record for the vaccine combined with advances in reverse genetics for negative strand viruses has expanded proposed uses for recombinant versions of measles vaccine as vectors for immunization against other infections and as oncolytic agents for a variety of tumors.
Method for detecting water equivalent of snow using secondary cosmic gamma radiation
Condreva, K.J.
1997-01-14
Water equivalent of accumulated snow determination by measurement of secondary background cosmic radiation attenuation by the snowpack. By measuring the attenuation of 3-10 MeV secondary gamma radiation it is possible to determine the water equivalent of snowpack. The apparatus is designed to operate remotely to determine the water equivalent of snow in areas which are difficult or hazardous to access during winter, accumulate the data as a function of time and transmit, by means of an associated telemetry system, the accumulated data back to a central data collection point for analysis. The electronic circuitry is designed so that a battery pack can be used to supply power. 4 figs.
A Compton scatter attenuation gamma ray spectrometer
NASA Technical Reports Server (NTRS)
Austin, W. E.
1972-01-01
A Compton scatter attenuation gamma ray spectrometer conceptual design is discussed for performing gamma spectral measurements in monodirectional gamma fields from 100 R per hour to 1,000,000 R per hour. Selectable Compton targets are used to scatter gamma photons onto an otherwise heavily shielded detector with changeable scattering efficiencies such that the count rate is maintained between 500 and 10,000 per second. Use of two sum-Compton coincident detectors, one for energies up to 1.5 MeV and the other for 600 keV to 10 MeV, will allow good peak to tail pulse height ratios to be obtained over the entire spectrum and reduces the neutron recoil background rate.
Lifetime and relative g factor measurements in 104 , 106 , 108Pd isotopes
NASA Astrophysics Data System (ADS)
Ilie, G.; Werner, V.; Radeck, D.; Ahn, T.; Beausang, C. W.; Bettermann, L.; Casperson, R. J.; Chevrier, R.; Cooper, N.; Bonniwell, T. C.; Heinz, A.; Holland, E.; McCarthy, D.; Pauerstein, B.; Smith, M. K.; Terry, J. R.; Williams, E.
2011-10-01
The purpose of this research was the proof-of-principle for the new g-plunger technique to measure the deorientation and the lifetime of a state after an inverse kinematics reaction. The deorientation effect is due to the hyperfine interaction between the nuclear spin and the surrounding electron configurations. The attenuation of γ-ray angular distributions has been measured for the 21+ and 41+ states of 104Pd, 106Pd and 108Pd. The beams with energies of 324 MeV, 330 MeV and 336 MeV, respectively, were Coulomb excited into their 21+ state on a 24Mg target. Forward scattered Mg was detected after passing a Cu foil, which served as a stopper for the beam. We measured the time-dependence of the attenuation as a function of distance, in parallel to measuring the lifetimes of the 21+ and 41+ states. This attenuation is used to measure the g factor of the decaying states relative to each other. In this work, hyperfine parameters have been calibrated for the Pd isotopes. The results of this work and a discussion of the parameterization used to fit the data in this work will be presented. Research was supported by the U.S. Department of Energy under Grant No. DE-FG02-91ER-40609.
[Characterization of a diode system for in vivo dosimetry with electron beams].
Ragona, R; Rossetti, V; Lucio, F; Anglesio, S; Giglioli, F R
2001-10-01
Current quality assurance regulation stresses the basic role of in vivo dosimetry. Our study evaluates the usefulness and reliability of semiconductor diodes in determining the electron absorbed dose. P-type EDE semiconductor detectors were irradiated with electron beams of different energies produced by a CGR Saturn Therac 20. The diode and ionization chamber response were compared, and effect of energy value, collimator opening, source skin distance and gantry angle on diode response was studied. Measurements show a maximum increment of about 20% in diode response increasing the beam energy (6-20 MeV). The response also increases with: collimator opening, reaching 5% with field sizes larger than 10x10 cm2 (with the exception of 20 MeV energy); SSD increase (with a maximum of 8% for 20 MeV); transversal gantry incidence, compared with the diode longitudinal axis; it does not affect the response in the interval of +/- 45 degrees. Absorbed dose attenuation at dmax, due to the presence of diode on the axis of the beam as a function of electron energy was also determined : the maximum attenuation value is 15% in 6 MeV electron beams. A dose calculation algorithm, taking into account diode response dependence was outlined. In vivo dosimetry was performed in 92 fields for 80 patients, with an agreement of +/-4 % (1 SD) between prescribed and measured dose. It is possible to use the EDE semiconductor detectors on a quality control program of dose delivery for electron beam therapy, but particular attention should be paid to the beam incidence angle and diode dose attenuation.
X-Ray Attenuation and Absorption for Materials of Dosimetric Interest
National Institute of Standards and Technology Data Gateway
SRD 126 X-Ray Attenuation and Absorption for Materials of Dosimetric Interest (Web, free access) Tables and graphs of the photon mass attenuation coefficient and the mass energy-absorption coefficient are presented for all of the elements Z = 1 to 92, and for 48 compounds and mixtures of radiological interest. The tables cover energies of the photon (x-ray, gamma ray, bremsstrahlung) from 1 keV to 20 MeV.
Azeez, Ali Basheer; Mohammed, Kahtan S; Abdullah, Mohd Mustafa Al Bakri; Hussin, Kamarudin; Sandu, Andrei Victor; Razak, Rafiza Abdul
2013-10-23
Samples of concrete contain various waste materials, such as iron particulates, steel balls of used ball bearings and slags from steel industry were assessed for their anti-radiation attenuation coefficient properties. The attenuation measurements were performed using gamma spectrometer of NaI (Tl) detector. The utilized radiation sources comprised 137 Cs and ⁶⁰Co radioactive elements with photon energies of 0.662 MeV for 137 Cs and two energy levels of 1.17 and 1.33 MeV for the ⁶⁰Co. Likewise the mean free paths for the tested samples were obtained. The aim of this work is to investigate the effect of the waste loading rates and the particulate dispersive manner within the concrete matrix on the attenuation coefficients. The maximum linear attenuation coefficient (μ) was attained for concrete incorporates iron filling wastes of 30 wt %. They were of 1.12 ± 1.31×10 -3 for 137 Cs and 0.92 ± 1.57 × 10 -3 for ⁶⁰Co. Substantial improvement in attenuation performance by 20%-25% was achieved for concrete samples incorporate iron fillings as opposed to that of steel ball samples at different (5%-30%) loading rates. The steel balls and the steel slags gave much inferior values. The microstructure, concrete-metal composite density, the homogeneity and particulate dispersion were examined and evaluated using different metallographic, microscopic and measurement facilities.
NASA Astrophysics Data System (ADS)
More, Chaitali V.; Lokhande, Rajkumar M.; Pawar, Pravina P.
2016-08-01
Photon attenuation coefficient calculation methods have been widely used to accurately study the properties of amino acids such as n-acetyl-L-tryptophan, n-acetyl-L-tyrosine, D-tryptophan, n-acetyl-L-glutamic acid, D-phenylalanine, and D-threonine. In this study, mass attenuation coefficients (μm) of these amino acids for 0.122-, 0.356-, 0.511-, 0.662-, 0.884-, 1.170, 1.275-, 1.330-MeV photons are determined using the radio-nuclides Co57, Ba133, Cs137, Na22, Mn54, and Co60. NaI (Tl) scintillation detection system was used to detect gamma rays with a resolution of 8.2% at 0.662 MeV. The calculated attenuation coefficient values were then used to determine total atomic cross sections (σt), molar extinction coefficients (ε), electronic cross sections (σe), effective atomic numbers (Zeff), and effective electron densities (Neff) of the amino acids. Theoretical values were calculated based on the XCOM data. Theoretical and experimental values are found to be in a good agreement (error<5%). The variations of μm, σt, ε, σe, Zeff, and Neff with energy are shown graphically. The values of μm, σt, ε, σe are higher at lower energies, and they decrease sharply as energy increases; by contrast, Zeff and Neff were found to be almost constant.
Azeez, Ali Basheer; Mohammed, Kahtan S.; Abdullah, Mohd Mustafa Al Bakri; Hussin, Kamarudin; Sandu, Andrei Victor; Razak, Rafiza Abdul
2013-01-01
Samples of concrete contain various waste materials, such as iron particulates, steel balls of used ball bearings and slags from steel industry were assessed for their anti-radiation attenuation coefficient properties. The attenuation measurements were performed using gamma spectrometer of NaI (Tl) detector. The utilized radiation sources comprised 137Cs and 60Co radioactive elements with photon energies of 0.662 MeV for 137Cs and two energy levels of 1.17 and 1.33 MeV for the 60Co. Likewise the mean free paths for the tested samples were obtained. The aim of this work is to investigate the effect of the waste loading rates and the particulate dispersive manner within the concrete matrix on the attenuation coefficients. The maximum linear attenuation coefficient (μ) was attained for concrete incorporates iron filling wastes of 30 wt %. They were of 1.12 ± 1.31×10−3 for 137Cs and 0.92 ± 1.57 × 10−3 for 60Co. Substantial improvement in attenuation performance by 20%–25% was achieved for concrete samples incorporate iron fillings as opposed to that of steel ball samples at different (5%–30%) loading rates. The steel balls and the steel slags gave much inferior values. The microstructure, concrete-metal composite density, the homogeneity and particulate dispersion were examined and evaluated using different metallographic, microscopic and measurement facilities. PMID:28788363
Lindskoug, B; Hultborn, A
1976-04-01
The density (g cm-3) and electron density (cm-3) of material from the anterior chest wall was determined. On the average, the difference in density between rib bone and intercostal soft tissue amounted to 17 per cent, while the difference in electron density was 7 per cent. The attenuation of high-energy electrons in specimens of rib bone, costal cartilage and sternum was determined by an experimental technique, using dosimeters of TLD material. The results of determinations of attenuation of 10 and 13 MeV electrons in fresh specimens are presented. It is concluded that electron radiation in the energy range of 10 to 13 MeV can be utilized for irradiation of lymph glands along the internal thoracic vessels without risk of underdosage.
Relative magnetic moments in ^106,108Pd from the new g-plunger technique
NASA Astrophysics Data System (ADS)
Ilie, G.; Werner, V.; Terry, J. R.; Radeck, D.; Ahn, T.; Bettermann, L.; Casperson, R. J.; Chevrier, R.; Cooper, N.; Heinz, A.; Holland, E.; McCarthy, D.; Smith, M. K.; Williams, E.; Beausang, C.; Bonniwell, T. C.; Pauerstein, B.
2010-11-01
The aim of the present work was the proof-of-principle for the new g-plunger technique to measure the deorientation and the lifetime of a state after an inverse kinematics reaction. The deorientation effect, observed in nuclei recoiling from thin targets into vacuum, is due to the hyperfine interactions between the nuclear spin and the surrounding electron configurations. The attenuation of γ-ray angular distributions has been measured for the 2^+1 states in ^106Pd and ^108Pd. ^106,108Pd beams with energies of 330 MeV and 336 MeV, respectively, were Coulomb excited into their 2^+1 state on a ^24Mg target. Forward scattered Mg was detected, passing a Cu foil which served as a stopper for the beam. We measured the time-dependence of the attenuation as a function of distance, in parallel to measuring the lifetimes of the 2^+1 states via RDDS method. This the attenuation is used to measure the g factor of the decaying states relative to each other. The results of this work will be presented.
Attenuation of thermal neutrons by an imperfect single crystal
NASA Astrophysics Data System (ADS)
Naguib, K.; Adib, M.
1996-06-01
A semi-empirical formula is given which allows one to calculate the total thermal cross section of an imperfect single crystal as a function of crystal constants, temperature and neutron energy E, in the energy range between 3 meV and 10 eV. The formula also includes the contribution of the parasitic Bragg scattering to the total cross section that takes into account the crystal mosaic spread value and its orientation with respect to the neutron beam direction. A computer program (ISCANF) was developed to calculate the total attenuation of neutrons using the proposed formula. The ISCANF program was applied to investigate the neutron attenuation through a copper single crystal. The calculated values of the neutron transmission through the imperfect copper single crystal were fitted to the measured ones in the energy range 3 - 40 meV at different crystal orientations. The result of fitting shows that use of the computer program ISCANF allows one to predict the behaviour of the total cross section of an imperfect copper single crystal for the whole energy range.
Shielding calculations for industrial 5/7.5MeV electron accelerators using the MCNP Monte Carlo Code
NASA Astrophysics Data System (ADS)
Peri, Eyal; Orion, Itzhak
2017-09-01
High energy X-rays from accelerators are used to irradiate food ingredients to prevent growth and development of unwanted biological organisms in food, and by that extend the shelf life of the products. The production of X-rays is done by accelerating 5 MeV electrons and bombarding them into a heavy target (high Z). Since 2004, the FDA has approved using 7.5 MeV energy, providing higher production rates with lower treatments costs. In this study we calculated all the essential data needed for a straightforward concrete shielding design of typical food accelerator rooms. The following evaluation is done using the MCNP Monte Carlo code system: (1) Angular dependence (0-180°) of photon dose rate for 5 MeV and 7.5 MeV electron beams bombarding iron, aluminum, gold, tantalum, and tungsten targets. (2) Angular dependence (0-180°) spectral distribution simulations of bremsstrahlung for gold, tantalum, and tungsten bombarded by 5 MeV and 7.5 MeV electron beams. (3) Concrete attenuation calculations in several photon emission angles for the 5 MeV and 7.5 MeV electron beams bombarding a tantalum target. Based on the simulation, we calculated the expected increase in dose rate for facilities intending to increase the energy from 5 MeV to 7.5 MeV, and the concrete width needed to be added in order to keep the existing dose rate unchanged.
Noise Reduction and Correction in the IPNS Linac ESEM
NASA Astrophysics Data System (ADS)
Dooling, J. C.; Brumwell, F. R.; Donley, L.; McMichael, G. E.; Stipp, V. F.
2004-11-01
The Energy Spread and Energy Monitor (ESEM) is an on-line, non-intrusive diagnostic used to characterize the output beam from the 200-MHz, 50-MeV IPNS linac. The energy spread is determined from a 3-size, longitudinal emittance measurement; whereas the energy is derived from time of flight (TOF) analysis. Signals are detected on 50-ohm, stripline beam position monitors (BPMs) terminated in their characteristic impedance. Each BPM is constructed with four striplines: top, bottom, left and right. The ESEM signals are taken from the bottom stripline in four separate BPM locations in the 50-MeV transport line between the linac and the synchrotron. Deterministic linac noise is sampled before and after the 70-microsecond macropulse. The noise phasor is vectorially subtracted from the beam signal. Noise subtraction is required at several frequencies, especially the fundamental and fifth harmonics (200 MHz and 1 GHz). It is also necessary to correct for attenuation and dispersion in the co-axial signal cables. Presently, the analysis assumes a single particle distribution to determine energy and energy spread. Work is on-going to allow for more realistic longitudinal distributions to be included in the analysis.
Added aluminum shielding to attenuate back scatter electrons from intra-oral lead shields.
Weidlich, G A; Nuesch, C E; Fuery, J J
1996-01-01
An intra-oral lead shield was developed that consists of a lead base with an aluminum layer that is placed upstream of the lead base. Several such shields with various thicknesses of Al layers were manufactured and quantitatively evaluated in 6 MeV and 12 MeV electron radiation by Thermoluminescent dosimetry (TLD) measurements. The clinical relevance was established by using a 5 cm backscatter block down-stream of the lead shield to simulate anatomical structures of the head and a 0.5 cm superflab bolus upstream of the Al layers of the shield to simulate the patient's lip or cheek. The TLDs were placed between the Al layers of the shield and the superflab to determine the intra-oral skin dose. TLD exposure results revealed that 59.8% of the skin dose at 6 MeV and 45.1% of the skin dose at 12 MeV is due to backscattered electrons. Introduction of a 3.0 mm thick Al layer reduces the backscatter contribution to 13.5% of the back scatter dose at 6 MeV and 56.3% of the back scatter dose at 12 MeV electron radiation.
CD147/EMMPRIN acts as a functional entry receptor for measles virus on epithelial cells.
Watanabe, Akira; Yoneda, Misako; Ikeda, Fusako; Terao-Muto, Yuri; Sato, Hiroki; Kai, Chieko
2010-05-01
Measles is a highly contagious human disease caused by measles virus (MeV) and remains the leading cause of death in children, particularly in developing countries. Wild-type MeV preferentially infects lymphocytes by using signaling lymphocytic activation molecule (SLAM), whose expression is restricted to hematopoietic cells, as a receptor. MeV also infects other epithelial and neuronal cells that do not express SLAM and causes pneumonia and diarrhea and, sometimes, serious symptoms such as measles encephalitis and subacute sclerosing panencephalitis. The discrepancy between the tissue tropism of MeV and the distribution of SLAM-positive cells suggests that there are unknown receptors other than SLAM for MeV. Here we identified CD147/EMMPRIN (extracellular matrix metalloproteinase inducer), a transmembrane glycoprotein, which acts as a receptor for MeV on epithelial cells. Furthermore, we found the incorporation of cyclophilin B (CypB), a cellular ligand for CD147, in MeV virions, and showed that inhibition of CypB incorporation significantly attenuated SLAM-independent infection on epithelial cells, while it had no effect on SLAM-dependent infection. To date, MeV infection was considered to be triggered by binding of its hemagglutinin (H) protein and cellular receptors. Our present study, however, indicates that MeV infection also occurs via CD147 and virion-associated CypB, independently of MeV H. Since CD147 is expressed in a variety of cells, including epithelial and neuronal cells, this molecule possibly functions as an entry receptor for MeV in SLAM-negative cells. This is the first report among members of the Mononegavirales that CD147 is used as a virus entry receptor via incorporated CypB in the virions.
CD147/EMMPRIN Acts as a Functional Entry Receptor for Measles Virus on Epithelial Cells▿
Watanabe, Akira; Yoneda, Misako; Ikeda, Fusako; Terao-Muto, Yuri; Sato, Hiroki; Kai, Chieko
2010-01-01
Measles is a highly contagious human disease caused by measles virus (MeV) and remains the leading cause of death in children, particularly in developing countries. Wild-type MeV preferentially infects lymphocytes by using signaling lymphocytic activation molecule (SLAM), whose expression is restricted to hematopoietic cells, as a receptor. MeV also infects other epithelial and neuronal cells that do not express SLAM and causes pneumonia and diarrhea and, sometimes, serious symptoms such as measles encephalitis and subacute sclerosing panencephalitis. The discrepancy between the tissue tropism of MeV and the distribution of SLAM-positive cells suggests that there are unknown receptors other than SLAM for MeV. Here we identified CD147/EMMPRIN (extracellular matrix metalloproteinase inducer), a transmembrane glycoprotein, which acts as a receptor for MeV on epithelial cells. Furthermore, we found the incorporation of cyclophilin B (CypB), a cellular ligand for CD147, in MeV virions, and showed that inhibition of CypB incorporation significantly attenuated SLAM-independent infection on epithelial cells, while it had no effect on SLAM-dependent infection. To date, MeV infection was considered to be triggered by binding of its hemagglutinin (H) protein and cellular receptors. Our present study, however, indicates that MeV infection also occurs via CD147 and virion-associated CypB, independently of MeV H. Since CD147 is expressed in a variety of cells, including epithelial and neuronal cells, this molecule possibly functions as an entry receptor for MeV in SLAM-negative cells. This is the first report among members of the Mononegavirales that CD147 is used as a virus entry receptor via incorporated CypB in the virions. PMID:20147391
Gamma ray detection with long NaI/Tl/ scintillator bars
NASA Technical Reports Server (NTRS)
Zych, A. D.; Tumer, O. T.; Dayton, B.
1983-01-01
Test measurements with a prototype NaI(Tl) scintillator for energy, position, and timing measurements in gamma ray astronomy are reported. The scintillator bar is 100 x 5 x 5 cu cm in size, and allows detection of the arrival times and pulse heights of signals from two photomultiplier tubes, one at each end of the bar. Data is gathered on the energy loss, linear position, and time-of-flight of gamma ray interactions within the bar over an energy range of 0.5-20 MeV. A mean attenuation coefficient of 0.015/cm has been determined, as have a FWHM resolution of 5 cm, 9.4%, and 10 nsec at an energy of 0.662 MeV. At 1.25 MeV the timing resolution was 6 nsec, and at 6.13 MeV the spatial resolution was 2.2 cm. The instrument is a prototype of a Compton scatter telescope being constructed for two balloon flights, one each in the Northern and Southern Hemispheres, in 1984.
A Green's function method for high charge and energy ion transport.
Chun, S Y; Khandelwal, G S; Wilson, J W
1996-02-01
A heavy-ion transport code using Green's function methods is developed. The low-order perturbation terms exhibiting the greatest energy variation are used as dominant energy-dependent terms, and the higher order collision terms are evaluated using nonperturbative methods. The recently revised NUCFRG database is used to evaluate the solution for comparison with experimental data for 625A MeV 20Ne and 517A MeV 40Ar ion beams. Improved agreements with the attenuation characteristics for neon ions are found, and reasonable agreement is obtained for the transport of argon ions in water.
Strong coupling between surface plasmon polariton and laser dye rhodamine 800
NASA Astrophysics Data System (ADS)
Valmorra, Federico; Bröll, Markus; Schwaiger, Stephan; Welzel, Nadine; Heitmann, Detlef; Mendach, Stefan
2011-08-01
We report on strong coupling between surface plasmon polaritons on a thin silver film and laser dye Rhodamine 800. Attenuated total reflection measurements reveal that the pure surface plasmon polaritons interact with the Rhodamine 800 absorption lines exhibiting pronounced anticrossings in the dispersion relation. We show that the corresponding energy gap can be tailored by the concentration of dye molecules in the dielectric matrix between 50 meV and 70 meV. We can well model our data by a classical transfer matrix approach as well as by a quantum mechanical coupled oscillator ansatz.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ramos-Mendez, J; Faddegon, B; Paganetti, H
2015-06-15
Purpose: We used TOPAS (TOPAS wraps and extends Geant4 for medical physicists) to compare Geant4 physics models with published data for neutron shielding calculations. Subsequently, we calculated the source terms and attenuation lengths (shielding data) of the total ambient dose equivalent (TADE) in concrete for neutrons produced by protons in brass. Methods: Stage1: The Bertini and Binary nuclear models available in Geant4 were compared with published attenuation at depth of the TADE in concrete and iron. Stage2: Shielding data of the TADE in concrete was calculated for 50– 200 MeV proton beams on brass. Stage3: Shielding data from Stage2 wasmore » extrapolated for 235 MeV proton beams. This data was used in a point-line-source analytical model to calculate the ambient dose per unit therapeutic dose at two locations inside one treatment room at the Francis H Burr Proton Therapy Center. Finally, we compared these results with experimental data and full TOPAS simulations. Results: At larger angles (∼130o) the TADE in concrete calculated with the Bertini model was about 9 times larger than that calculated with the Binary model. The attenuation length in concrete calculated with the Binary model agreed with published data within 7%±0.4% (statistical uncertainty) for the deepest regions and 5%±0.1% for shallower regions. For iron the agreement was within 3%±0.1%. The ambient dose per therapeutic dose calculated with the Binary model, relative to the experimental data, was a ratio of 0.93±0.16 and 1.23±0.24 for two locations. The analytical model overestimated the dose by four orders of magnitude. These differences are attributed to the complexity of the geometry. Conclusion: The Binary and Bertini models gave comparable results, with the Binary model giving the best agreement with published data at large angle. Shielding data we calculated using the Binary model is useful for fast shielding calculations with other analytical models. This work was supported by National Cancer Institute Grant R01CA140735.« less
ETFE polymer bombarded with 1 MeV proton
NASA Astrophysics Data System (ADS)
Parada, M. A.; de Almeida, A.; Muntele, I.; Muntele, C.; Delalez, N.; Ila, D.
2005-12-01
The ethylenetetrafluoroethylene (ETFE) is a polymer formed by alternating ethylene and tetrafluoroethylene segments. It has high impact resistance and useful mechanical properties. ETFE can be used as components of pumps, valves, tie wraps, and electrical components. It can also be applied in the field of medical physics as intra venous catheters and as radiation dosimeter. When a material is exposed to the ionizing radiation, it suffers damage that depends on the type, energy and intensity of the radiation. In order to determine the radiation damage mechanism, ETFE films were bombarded with 1 MeV protons to the fluence between 1 × 1011 and 1 × 1016 protons/cm2 and the chemical species emitted during the bombardment were measured with residual gas analysis (RGA) and show that HF gas is the entity preferentially emitted. Optical absorption photospectrometry (OAP) and attenuated total reflectometry fourier transform infrared (ATR-FTIR) shows quantitative chemical evidence of the damage. Our results show that damage is detectable at low proton fluence, but damage that can compromise the application in dosimetry occurs only for fluence greater than 1014 protons/cm2.
Development of test specimens to obtain the transmission factors to attenuate photons of 0.511 MeV
NASA Astrophysics Data System (ADS)
Costa, J. J. S.; Cardoso, D. D.; Gavazza, S.; Oliveira, C. L.; Morales, R. K.; Amorim, A. S.; Balthar, M. C. V.; Oliveira, L. S. R.
2018-03-01
For designing a shielding, it is necessary, mainly, to determine or have access to the following parameters: transmission factors of the material used and type of radiation to be shielded. Cylindrical test specimens with different thicknesses were developed for experimentally obtaining the material transmission factor for shielding calculation. The cylindrical test specimens were made considering the geometric characteristics of the detector, the ease of production and the energy of 0.511 MeV from the 18F-FDG decay. A type of concrete widely used in Brazil was used in the preparation of the cylindrical test specimens.
Determination of Neutron Spectra in a Graphite Sphere for Fusion Reactor Studies
NASA Astrophysics Data System (ADS)
Bashter, I. B.; Cooper, P. N.
Calculated and experimental results for the neutron spectra at different radii in a graphite sphere irradiated with 14.1 MeV neutrons were shown to be in satisfactory agreement over the energy range 14.1 to 1.8 MeV neutrons. A group of curves were constructed which gives the radius of a graphite sphere shield required to attenuate the neutron intensity to a certain value. The data set used in the present work, with carbon-12 cross section, is shown to be useful for spherical calculations.Translated AbstractDie Bestimmung der Neutronenspektren in einer GraphitkugelDie Übereinstimmung experimentell bestimmter und berechneter Neutronenspektren in Abhängigkeit vom Ort in einer Graphitkugel wird in einem Energiebereich von 14,1 bis 1,8 MeV (bei einer Ausgangsenergie von 14,1 MeV je Neutron) gezeigt. Eine Gruppe von Kurven wird konstruiert, die den für eine bestimmte Dämpfung der Neutronenintensität notwendigen Radius einer Graphitkugel angeben. Es wird nachgewiesen, daß die in der Arbeit benutzte Datenbank für den 12C-Wirkungsquerschnitt in sphärischen Geometrien anwendbar ist.
Method for detecting water equivalent of snow using secondary cosmic gamma radiation
Condreva, Kenneth J.
1997-01-01
Water equivalent of accumulated snow determination by measurement of secondary background cosmic radiation attenuation by the snowpack. By measuring the attentuation of 3-10 MeV secondary gamma radiation it is possible to determine the water equivalent of snowpack. The apparatus is designed to operate remotely to determine the water equivalent of snow in areas which are difficult or hazardous to access during winter, accumulate the data as a function of time and transmit, by means of an associated telemetry system, the accumulated data back to a central data collection point for analysis. The electronic circuitry is designed so that a battery pack can be used to supply power.
Saito, Masatoshi
2015-07-01
For accurate tissue inhomogeneity correction in radiotherapy treatment planning, the author previously proposed a simple conversion of the energy-subtracted computed tomography (CT) number to an electron density (ΔHU-ρe conversion), which provides a single linear relationship between ΔHU and ρe over a wide ρe range. The purpose of the present study was to reveal the relation between the ΔHU image for ρe calibration and a virtually monochromatic CT image by performing numerical analyses based on the basis material decomposition in dual-energy CT. The author determined the weighting factor, α0, of the ΔHU-ρe conversion through numerical analyses of the International Commission on Radiation Units and Measurements Report-46 human body tissues using their attenuation coefficients and given ρe values. Another weighting factor, α(E), for synthesizing a virtual monochromatic CT image from high- and low-kV CT images, was also calculated in the energy range of 0.03 < E < 5 MeV, assuming that cortical bone and water were the basis materials. The mass attenuation coefficients for these materials were obtained using the xcom photon cross sections database. The effective x-ray energies used to calculate the attenuation were chosen to imitate a dual-source CT scanner operated at 80-140 and 100-140 kV/Sn. The determined α0 values were 0.455 for 80-140 kV/Sn and 0.743 for 100-140 kV/Sn. These values coincided almost perfectly with the respective maximal points of the calculated α(E) curves located at approximately 1 MeV, in which the photon-matter interaction in human body tissues is exclusively the incoherent (Compton) scattering. The ΔHU image could be regarded substantially as a CT image acquired with monoenergetic 1-MeV photons, which provides a linear relationship between CT numbers and electron densities.
NASA Astrophysics Data System (ADS)
Wang, Chao; Xiao, Jun; Luo, Xiaobing
2016-10-01
The neutron inelastic scattering cross section of 115In has been measured by the activation technique at neutron energies of 2.95, 3.94, and 5.24 MeV with the neutron capture cross sections of 197Au as an internal standard. The effects of multiple scattering and flux attenuation were corrected using the Monte Carlo code GEANT4. Based on the experimental values, the 115In neutron inelastic scattering cross sections data were theoretically calculated between the 1 and 15 MeV with the TALYS software code, the theoretical results of this study are in reasonable agreement with the available experimental results.
Lifetimes in Te 124 : Examining critical-point symmetry in the Te nuclei
Hicks, S. F.; Vanhoy, J. R.; Burkett, P. G.; ...
2017-03-27
The Doppler-shift attenuation method following inelastic neutron scattering was used to determine the lifetimes of nuclear levels to 3.3-MeV excitation in 124Te. Level energies and spins, γ -ray energies and branching ratios, and multipole-mixing ratios were deduced from measured γ-ray angular distributions at incident neutron energies of 2.40 and 3.30 MeV, γ-ray excitation functions, and γγ coincidence measurements. The newly obtained reduced transition probabilities and level energies for 124Te were compared to critical-point symmetry model predictions. The E(5) and β 4 potential critical-point symmetries were also investigated in 122Te and 126Te.
X-ray radiography for container inspection
Katz, Jonathan I [Clayton, MO; Morris, Christopher L [Los Alamos, NM
2011-06-07
Arrangements of X-ray inspection systems are described for inspecting high-z materials in voluminous objects such as containers. Inspection methods may involve generating a radiographic image based on detected attenuation corresponding to a pulsed beams of radiation transmitted through a voluminous object. The pulsed beams of radiation are generated by a high-energy source and transmitted substantially downward along an incident angle, of approximately 1.degree. to 30.degree., to a vertical axis extending through the voluminous object. The generated radiographic image may be analyzed to detect on localized high attenuation representative of high-z materials and to discriminate high-z materials from lower and intermediate-z materials on the basis of the high density and greater attenuation of high-z material for higher energy (3-10 MeV) X-rays, and the compact nature of threatening masses of fissionable materials.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bazalova, M; Ahmad, M; Fahrig, R
Purpose: To evaluate x-ray fluorescence computed tomography induced with proton beams (pXFCT) for imaging of gold contrast agent. Methods: Proton-induced x-ray fluorescence was studied by means of Monte Carlo (MC) simulations using TOPAS, a MC code based on GEANT4. First, proton-induced K-shell and L-shell fluorescence was studied as a function of proton beam energy and 1) depth in water and 2) size of contrast object. Second, pXFCT images of a 2-cm diameter cylindrical phantom with four 5- mm diameter contrast vials and of a 20-cm diameter phantom with 1-cm diameter vials were simulated. Contrast vials were filled with water andmore » water solutions with 1-5% gold per weight. Proton beam energies were varied from 70-250MeV. pXFCT sinograms were generated based on the net number of gold K-shell or L-shell x-rays determined by interpolations from the neighboring 0.5keV energy bins of spectra collected with an idealized 4π detector. pXFCT images were reconstructed with filtered-back projection, and no attenuation correction was applied. Results: Proton induced x-ray fluorescence spectra showed very low background compared to x-ray induced fluorescence. Proton induced L-shell fluorescence had a higher cross-section compared to K-shell fluorescence. Excitation of L-shell fluorescence was most efficient for low-energy protons, i.e. at the Bragg peak. K-shell fluorescence increased with increasing proton beam energy and object size. The 2% and 5% gold contrast vials were accurately reconstructed in K-shell pXFCT images of both the 2-cm and 20-cm diameter phantoms. Small phantom L-shell pXFCT image required attenuation correction and had a higher sensitivity for 70MeV protons compared to 250MeV protons. With attenuation correction, L-shell pXFCT might be a feasible option for imaging of small size (∼2cm) objects. Imaging doses for all simulations were 5-30cGy. Conclusion: Proton induced x-ray fluorescence CT promises to be an alternative quantitative imaging technique to the commonly considered XFCT imaging with x-ray beams.« less
Rota, Paul A; Moss, William J; Takeda, Makoto; de Swart, Rik L; Thompson, Kimberly M; Goodson, James L
2016-07-14
Measles is an infectious disease in humans caused by the measles virus (MeV). Before the introduction of an effective measles vaccine, virtually everyone experienced measles during childhood. Symptoms of measles include fever and maculopapular skin rash accompanied by cough, coryza and/or conjunctivitis. MeV causes immunosuppression, and severe sequelae of measles include pneumonia, gastroenteritis, blindness, measles inclusion body encephalitis and subacute sclerosing panencephalitis. Case confirmation depends on clinical presentation and results of laboratory tests, including the detection of anti-MeV IgM antibodies and/or viral RNA. All current measles vaccines contain a live attenuated strain of MeV, and great progress has been made to increase global vaccination coverage to drive down the incidence of measles. However, endemic transmission continues in many parts of the world. Measles remains a considerable cause of childhood mortality worldwide, with estimates that >100,000 fatal cases occur each year. Case fatality ratio estimates vary from <0.01% in industrialized countries to >5% in developing countries. All six WHO regions have set goals to eliminate endemic transmission of MeV by achieving and maintaining high levels of vaccination coverage accompanied by a sensitive surveillance system. Because of the availability of a highly effective and relatively inexpensive vaccine, the monotypic nature of the virus and the lack of an animal reservoir, measles is considered a candidate for eradication.
Chlorine signal attenuation in concrete.
Naqvi, A A; Maslehuddin, M; Ur-Rehman, Khateeb; Al-Amoudi, O S B
2015-11-01
The intensity of prompt gamma-ray was measured at various depths from chlorine-contaminated silica fume (SF) concrete slab concrete specimens using portable neutron generator-based prompt gamma-ray setup. The intensity of 6.11MeV chloride gamma-rays was measured from the chloride contaminated slab at distance of 15.25, 20.25, 25.25, 30.25 and 35.25cm from neutron target in a SF cement concrete slab specimens. Due to attenuation of thermal neutron flux and emitted gamma-ray intensity in SF cement concrete at various depths, the measured intensity of chlorine gamma-rays decreases non-linearly with increasing depth in concrete. A good agreement was noted between the experimental results and the results of Monte Carlo simulation. This study has provided useful experimental data for evaluating the chloride contamination in the SF concrete utilizing gamma-ray attenuation method. Copyright © 2015 Elsevier Ltd. All rights reserved.
Analysis of the vp2 gene sequence of a new mutated mink enteritis parvovirus strain in PR China
2010-01-01
Background Mink enteritis virus (MEV) causes a highly contagious viral disease of mink with a worldwide distribution. MEV has a linear, single-stranded, negative-sense DNA with a genome length of approximately 5,000 bp. The VP2 protein is the major structural protein of the parvovirus encoded by the vp2 gene. VP2 is highly antigenic and plays important roles in determining viral host ranges and tissue tropisms. This study describes the bionomics and vp2 gene analysis of a mutated strain, MEV-DL, which was isolated recently in China and outlines its homologous relationships with other selected strains registered in Genbank. Results The MEV-DL strain can infect F81 cells with cytopathic effects. Pig erythrocytes were agglutinated by the MEV-DL strain. The generation of MEV-DL in F81 cells could infect mink within three months and cause a disease that was similar to that caused by wild-type MEV. A comparative analysis of the vp2 gene nucleotide (nt) sequence of MEV-DL showed that this was more than 99% homologous with other mink enteritis parvoviruses in Genbank. However, the nucleotide residues at positions 1,065 and 1,238 in the MEV-DL strain of the vp2 gene differed from those of all the other MEV strains described previously. It is noteworthy that the mutation at the nucleotide residues position 1,238 led to Asp/Gly replacement. This may lead to structural changes. A phylogenetic tree and sequence distance table were obtained, which showed that the MEV-DL and ZYL-1 strains had the closest inheritance distance. Conclusions A new variation of the vp2 gene exists in the MEV-DL strain, which may lead to structural changes of the VP2 protein. Phylogenetic analysis showed that MEV-DL may originate from the ZYL-1 strain in DaLian. PMID:20540765
Prompt radiation, shielding and induced radioactivity in a high-power 160 MeV proton linac
NASA Astrophysics Data System (ADS)
Magistris, Matteo; Silari, Marco
2006-06-01
CERN is designing a 160 MeV proton linear accelerator, both for a future intensity upgrade of the LHC and as a possible first stage of a 2.2 GeV superconducting proton linac. A first estimate of the required shielding was obtained by means of a simple analytical model. The source terms and the attenuation lengths used in the present study were calculated with the Monte Carlo cascade code FLUKA. Detailed FLUKA simulations were performed to investigate the contribution of neutron skyshine and backscattering to the expected dose rate in the areas around the linac tunnel. An estimate of the induced radioactivity in the magnets, vacuum chamber, the cooling system and the concrete shield was performed. A preliminary thermal study of the beam dump is also discussed.
Energy determination in industrial X-ray processing facilities
NASA Astrophysics Data System (ADS)
Cleland, M. R.; Gregoire, O.; Stichelbaut, F.; Gomola, I.; Galloway, R. A.; Schlecht, J.
2005-12-01
In industrial irradiation facilities, the determination of maximum photon or electron energy is important for regulated processes, such as food irradiation, and for assurance of treatment reproducibility. With electron beam irradiators, this has been done by measuring the depth-dose distribution in a homogeneous material. For X-ray irradiators, an analogous method has not yet been recommended. This paper describes a procedure suitable for typical industrial irradiation processes, which is based on common practice in the field of therapeutic X-ray treatment. It utilizes a measurement of the slope of the exponential attenuation curve of X-rays in a thick stack of polyethylene plates. Monte Carlo simulations and experimental tests have been performed to verify the suitability and accuracy of the method between 3 MeV and 8 MeV.
NASA Astrophysics Data System (ADS)
Verdipoor, Khatibeh; Alemi, Abdolali; Mesbahi, Asghar
2018-06-01
Novel shielding materials for photons based on silicon resin and WO3, PbO, and Bi2O3 Micro and Nano-particles were designed and their mass attenuation coefficients were calculated using Monte Carlo (MC) method. Using lattice cards in MCNPX code, micro and nanoparticles with sizes of 100 nm and 1 μm was designed inside a silicon resin matrix. Narrow beam geometry was simulated to calculate the attenuation coefficients of samples against mono-energetic beams of Co60 (1.17 and 1.33 MeV), Cs137 (663.8 KeV), and Ba133 (355.9 KeV). The shielding samples made of nanoparticles had higher mass attenuation coefficients, up to 17% relative to those made of microparticles. The superiority of nano-shields relative to micro-shields was dependent on the filler concentration and the energy of photons. PbO, and Bi2O3 nanoparticles showed higher attenuation compared to WO3 nanoparticles in studied energies. Fabrication of novel shielding materials using PbO, and Bi2O3 nanoparticles is recommended for application in radiation protection against photon beams.
Investigations of some building materials for γ-rays shielding effectiveness
NASA Astrophysics Data System (ADS)
Mann, Kulwinder Singh; Kaur, Baljit; Sidhu, Gurdeep Singh; Kumar, Ajay
2013-06-01
For construction of residential and non-residential buildings bricks are used as building blocks. Bricks are made from mixtures of sand, clay, cement, fly ash, gypsum, red mud and lime. Shielding effectiveness of five soil samples and two fly ash samples have been investigated using some energy absorption parameters (Mass attenuation coefficients, mass energy absorption coefficients, KERMA (kinetic energy released per unit mass), HVL, equivalent atomic number and electron densities) firstly at 14 different energies from 81-1332 keV then extended to wide energy range 0.015-15 MeV. The soil sample with maximum shielding effectiveness has been used for making eight fly ash bricks [(Lime)0.15 (Gypsum)0.05 (Fly Ash)x (Soil)0.8-x, where values of x are from 0.4-0.7]. High Purity Germanium (HPGe) detector has been used for gamma-ray spectroscopy. The elemental compositions of samples were analysed using an energy dispersive X-ray fluorescence (EDXRF) spectrometer. The agreements of theoretical and experimental values of mass attenuation coefficient have been found to be quite satisfactory. It has been verified that common brick possess the maximum shielding effectiveness for wide energy range 0.015-15 MeV. The results have been shown graphically with some useful conclusions for making radiation safe buildings.
Elastic scattering of ^4He by ^6Li at E(^4He) = 24, 25, and 26 MeV
NASA Astrophysics Data System (ADS)
Bartosz, E. E.; Cathers, P. D.; Kemper, K. W.; Maréchal, F.; Rusek, K.
1998-11-01
A previous optical model analysis of the elastic scattering of ^4He by ^6Li at E(^4He) = 18.5 MeV (P. V. Green, K. W. Kemper, P. L. Kerr, K. Mohajeri, E. G. Myers, D. Robson, K. Rusek and I. J. Thompson, Phys. Rev. C 53) 2862 (1996)., as well as a cluster-folded continuum- discretized coupled channels analysis (K. Rusek, P. V. Green, P. L. Kerr, and K. W. Kemper, Phys. Rev. C 56) 1895 (1997)., resulted in a good description of the data set, but the optical model analysis yielded a poor description of the 25 MeV elastic scattering data measured at the same time. New elastic and inelastic scattering angular distribution cross sections are reported for ^4He + ^6Li at E(^4He) = 24, 25 and 26 MeV. Three energies were used to rule out anomalous scattering at 25 MeV. The results of a cluster-folded continuum- discretized coupled channels analysis similar to that used with the 18.5 MeV data are presented for the three new data sets at 24, 25, and 26 MeV.
Time evolution of the spectral break in the high-energy extra component of GRB 090926A
NASA Astrophysics Data System (ADS)
Yassine, M.; Piron, F.; Mochkovitch, R.; Daigne, F.
2017-10-01
Aims: The prompt light curve of the long GRB 090926A reveals a short pulse 10 s after the beginning of the burst emission, which has been observed by the Fermi observatory from the keV to the GeV energy domain. During this bright spike, the high-energy emission from GRB 090926A underwent a sudden hardening above 10 MeV in the form of an additional power-law component exhibiting a spectral attenuation at a few hundreds of MeV. This high-energy break has been previously interpreted in terms of gamma-ray opacity to pair creation and has been used to estimate the bulk Lorentz factor of the outflow. In this article, we report on a new time-resolved analysis of the GRB 090926A broadband spectrum during its prompt phase and on its interpretation in the framework of prompt emission models. Methods: We characterized the emission from GRB 090926A at the highest energies with Pass 8 data from the Fermi Large Area Telescope (LAT), which offer a greater sensitivity than any data set used in previous studies of this burst, particularly in the 30-100 MeV energy band. Then, we combined the LAT data with the Fermi Gamma-ray Burst Monitor (GBM) in joint spectral fits to characterize the time evolution of the broadband spectrum from keV to GeV energies. We paid careful attention to the systematic effects that arise from the uncertainties on the LAT response. Finally, we performed a temporal analysis of the light curves and we computed the variability timescales from keV to GeV energies during and after the bright spike. Results: Our analysis confirms and better constrains the spectral break, which has been previously reported during the bright spike. Furthermore, it reveals that the spectral attenuation persists at later times with an increase of the break characteristic energy up to the GeV domain until the end of the prompt phase. We discuss these results in terms of keV-MeV synchroton radiation of electrons accelerated during the dissipation of the jet energy and inverse Compton emission at higher energies. We interpret the high-energy spectral break as caused by photon opacity to pair creation. Requiring that all emissions are produced above the photosphere of GRB 090926A, we compute the bulk Lorentz factor of the outflow, Γ. The latter decreases from 230 during the spike to 100 at the end of the prompt emission. Assuming, instead, that the spectral break reflects the natural curvature of the inverse Compton spectrum, lower limits corresponding to larger values of Γ are also derived. Combined with the extreme temporal variability of GRB 090926A, these Lorentz factors lead to emission radii R 1014 cm, which are consistent with an internal origin of both the keV-MeV and GeV prompt emissions.
Nuclear Resonance Fluorescence of U-235 above 3 MeV
DOE Office of Scientific and Technical Information (OSTI.GOV)
Warren, Glen A.; Caggiano, Joseph A.; Miller, Erin A.
Pacific Northwest National Laboratory and Passport Systems have collaborated to conduct measurements to search for a nuclear resonance fluorescence response of U-235 from 3 to 5 MeV using an 8 g sample of highly enriched uranium. These new measurements complement previously reported measurements below 3 MeV. Preliminary analysis indicates that no strong resonances exist for U-235 in this energy range. A second set of measurements focused on a signature search in the 5 to 10 MeV range is still under analysis.
Dong, Mengge; Xue, Xiangxin; Kumar, Ashok; Yang, He; Sayyed, M I; Liu, Shan; Bu, Erjun
2018-02-15
A novel, unconventional, low cost, eco-friendly and effective shielding materials have been made utilizing the hot dip galvanizing slag using the heat waste from itself, thereby saving the natural resources and preventing the environmental pollution. SEM-EDS of shielding materials indicates that the other elements are distributed in Zn element. The mass attenuation properties of shielding materials were measured using a narrow beam geometrical setup at 0.662MeV, 1.17MeV and 1.33MeV. The half value thickness layer, effective atomic number, and electron density were used to analyze the shielding performance of the materials. The EBFs and EABFs for the prepared shielding materials were also studied with incident photon energy for penetration depths upto 40mfp. The shielding effectiveness has been compared with lead, iron, zinc, some standard shielding concretes, different glasses and some alloys. The shielding effectiveness of the prepared samples is almost found comparable to iron, zinc, selected alloys and glasses while better than some standard shielding concretes. In addition, it is also found that the bending strength of all shielding materials is more than 110MPa. Copyright © 2017 Elsevier B.V. All rights reserved.
Using a fast-neutron spectrometer system to candle luggage for hidden explosives
NASA Astrophysics Data System (ADS)
Lefevre, Harlan W.; Rasmussen, R. J.; Chmelik, Michael S.; Schofield, R. M. S.; Sieger, G. E.; Overley, Jack C.
1997-02-01
A continuous spectrum of neutron switch energies up to 8.2 MeV is produced by a 4.2-MeV nanosecond-pulsed deuteron beam slowing down in a thick beryllium target. The spectrum form the locally shielded target is collimated to a horizontal fan-beam and delivered to a row of 16, 6-cm square plastic scintillators located 4 m from the neutron source. The scintillators are coupled to 12-stage photomultiplier tubes, constant-fraction discriminators, time-to-amplitude converters, analog-to-digital converters, and digital memories. Unattenuated neutron-source spectra and background spectra ar recorded. Luggage is stepped through the fan beam by an automated lift located 2 m from the neutron source. Transmission spectra are measured, and are transferred to a computer while the location is advanced one pixel width. As the next set of spectra is being measured, the computer calculates neutron attenuations for the previous set, deconvolutes attenuations into projected elemental number densities, and determines the explosive likelihood for each pixel. With a time-averaged deuteron beam current o 1(mu) A, a suitcase 60-cm long can be automatically imaged in 1600s. We will suggest that time can be reduced to 8s or less with straight-forward improvements. The following paper describes the explosives recognition algorithm and presents the results of teste with explosives.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hasegawa, Shuichi; Takashima, Ryuta; Todoriki, Masaru
2011-03-15
We evaluate the simplified method using the Lambert-Beer law to measure the temperature of bremsstrahlung photon generated by an ultraintense laser. Analytical values are compared to the results of the Monte Carlo calculation of GEANT4 and they agreed very well on the condition of the appropriate distance between the attenuator and the detector. We performed the experiment to measure the temperature of bremsstrahlung x-ray emitted from a metal target irradiated by a Ti:sapphire laser with 76 mJ, 72 fs, 2.2 x 10{sup 18} W/cm{sup 2}. For a Cu target of 30 {mu}m thick, the photon temperature was reasonably determined tomore » be 0.18 MeV, which is in good agreement with previous studies.« less
NASA Astrophysics Data System (ADS)
Matsuda, Norihiro; Izumi, Yuichi; Yamanaka, Yoshiyuki; Gandou, Toshiyuki; Yamada, Masaaki; Oishi, Koji
2017-09-01
Measurements of reaction rates by secondary neutrons produced from beam losses by 17-MeV protons are conducted at a compact cyclotron facility with the foil activation method. The experimentally obtained distribution of the reaction rates of 197Au (n, γ) 198Au on the concrete walls suggests that a target and an electrostatic deflector as machine components for beam extraction of the compact cyclotron are principal beam loss points. The measurements are compared with calculations by the Monte Carlo code: PHITS. The calculated results based on the beam losses are good agreements with the measured ones within 21%. In this compact cyclotron facility, exponential attenuations with the distance from the electrostatic deflector in the distributions of the measured reaction rates were observed, which was looser than that by the inverse square of distance.
Lifetime measurements in N=Z 72Kr
NASA Astrophysics Data System (ADS)
Andreoiu, C.; Svensson, C. E.; Austin, R. A. E.; Carpenter, M. P.; Dashdorj, D.; Finlay, P.; Freeman, S. J.; Garrett, P. E.; Görgen, A.; Greene, J.; Grinyer, G. F.; Hyland, B.; Jenkins, D.; Johnston-Theasby, F.; Joshi, P.; Machiavelli, A. O.; Moore, F.; Mukherjee, G.; Phillips, A. A.; Reviol, W.; Sarantites, D. G.; Schumaker, M. A.; Seweryniak, D.; Smith, M. B.; Valiente-Dobón, J. J.; Wadsworth, R.
2006-07-01
High-spin states in the N=Z nucleus 72Kr have been populated in the 40Ca(40Ca, 2α)72Kr fusion-evaporation reaction at a beam energy of 165 MeV and using a thin isotopically enriched 40Ca target. The experiment, performed at Argonne National Laboratory close to Chicago, USA, employed the Gammasphere array for γ-ray detection coupled to the Microball array for charged particle detection. The previously observed bands in 72Kr were extended to a higher excitation energy of ~24 MeV and higher angular momentum of 30planck. Using the Doppler-shift attenuation method, the lifetimes of high-spin states were measured for the first time in order to investigate deformation changes associated with the g9/2 proton and neutron alignments in this N=Z nucleus. An excellent agreement with theoretical calculations including only standard t=1 np pairing was observed.
High-spin lifetime measurements in the N=Z nucleus Kr72
NASA Astrophysics Data System (ADS)
Andreoiu, C.; Svensson, C. E.; Afanasjev, A. V.; Austin, R. A. E.; Carpenter, M. P.; Dashdorj, D.; Finlay, P.; Freeman, S. J.; Garrett, P. E.; Greene, J.; Grinyer, G. F.; Görgen, A.; Hyland, B.; Jenkins, D.; Johnston-Theasby, F.; Joshi, P.; Machiavelli, A. O.; Moore, F.; Mukherjee, G.; Phillips, A. A.; Reviol, W.; Sarantites, D. G.; Schumaker, M. A.; Seweryniak, D.; Smith, M. B.; Valiente-Dobón, J. J.; Wadsworth, R.
2007-04-01
High-spin states in the N=Z nucleus Kr72 have been populated in the Ca40(Ca40, 2α)Kr72 fusion-evaporation reaction at a beam energy of 165 MeV using the Gammasphere array for γ-ray detection coupled to the Microball array for charged particle detection. The previously observed bands in Kr72 were extended to an excitation energy of ˜24 MeV and angular momentum of 30ℏ. Using the Doppler shift attenuation method the lifetimes of high-spin states were measured for the first time. Excellent agreement between the results of calculations within the isovector mean field theory and experiment is observed both for rotational and deformation properties. No enhancement of quadrupole deformation expected in the presence of isoscalar t=0 np pairing is observed. Current data do not show any evidence for the existence of the isoscalar np pairing.
Genetic characterization of measles virus in the Philippines, 2008-2011.
Centeno, Rex; Fuji, Naoko; Okamoto, Michiko; Dapat, Clyde; Saito, Mariko; Tandoc, Amado; Lupisan, Socorro; Oshitani, Hitoshi
2015-06-03
Large outbreaks of measles occurred in the Philippines in 2010 and 2011. Genetic analysis was performed to identify the genotype of measles virus (MeV) that was responsible for the large outbreaks. A total of 114 representative MeVs that were detected in the Philippines from 2008 to 2011 were analyzed by sequencing the C-terminal region of nucleocapsid (N) gene and partial hemagglutinin (H) gene and by inferring the phylogenetic trees. Genetic analysis showed that genotype D9 was the predominant circulating strain during the 4-year study period. Genotype D9 was detected in 23 samples (92%) by N gene sequencing and 93 samples (94%) by H gene analysis. Sporadic cases of genotype G3 MeV were identified in 2 samples (8%) by N gene sequencing and 6 samples (6%) by H gene analysis. Genotype G3 MeV was detected mainly in Panay Island in 2009 and 2010. Molecular clock analysis of N gene showed that the recent genotype D9 viruses that caused the big outbreaks in 2010 and 2011 diverged from a common ancestor in 2005 in one of the neighboring Southeast Asian countries, where D9 was endemic. These big outbreaks of measles resulted in a spillover and were associated with genotype D9 MeV importation to Japan and the USA. Genotype D9 MeV became endemic and caused two big outbreaks in the Philippines in 2010 and 2011. Genotype G3 MeV was detected sporadically with limited geographic distribution. This study highlights the importance of genetic analysis not only in helping with the assessment of measles elimination program in the country but also in elucidating the transmission dynamics of measles virus.
NASA Astrophysics Data System (ADS)
Lakshminarayana, G.; Sayyed, M. I.; Baki, S. O.; Lira, A.; Dong, M. G.; Kaky, Kawa M.; Kityk, I. V.; Mahdi, M. A.
2018-05-01
Different concentrations (0.1‒2.0 mol%) of Tm3+-doped multicomponent borosilicate glasses with 10 mol% Li2O (alkali) or MgO (alkaline) have been synthesized and their optical absorption and radiation shielding features were studied. For both Li2O and MgO series 0.5 mol% Tm3+-doped glass samples, the evaluated Ωλ ( λ = 2, 4, and 6) Judd-Ofelt (JO) intensity parameters from experimental oscillator strengths were used in estimating the radiative transition probabilities ( A R), branching ratios ( β R), and radiative lifetimes ( τ R) for several emission transitions. Using the XCOM software, the mass attenuation coefficients ( µ/ ρ) for all the fabricated glasses were evaluated within the 0.015‒10 MeV energy range. Also, the ( µ/ ρ) values were calculated at 0.356, 0.662, 1.173, and 1.33 MeV photon energies by MCNP5 simulation code and the results were compared with those obtained by XCOM. The ( µ/ ρ) values for Li2O, as well as MgO series glasses, increase with the addition of Tm2O3 and these values for MgO series glasses are slightly higher with respect to Li2O series glasses. From the ( µ/ ρ) values, effective atomic number ( Z eff), half-value layer (HVL), and mean free path (MFP) were calculated and the HVL and MFP results revealed that high-energy photons have more penetration into a glass sample compared to low-energy photons. Further, geometric progression (GP) fitting method was utilized to calculate the exposure buildup factor (EBF) within the 0.015‒15 MeV energy range. The 2.0 mol% Tm2O3-doped glasses show a better ability to attenuate gamma-rays in comparison to other glass samples, so the addition of Tm2O3 content leads to improvement of the shielding efficiency of the prepared glasses.
MeV ion-beam analysis of optical data storage films
NASA Technical Reports Server (NTRS)
Leavitt, J. A.; Mcintyre, L. C., Jr.; Lin, Z.
1993-01-01
Our objectives are threefold: (1) to accurately characterize optical data storage films by MeV ion-beam analysis (IBA) for ODSC collaborators; (2) to develop new and/or improved analysis techniques; and (3) to expand the capabilities of the IBA facility itself. Using H-1(+), He-4(+), and N-15(++) ion beams in the 1.5 MeV to 10 MeV energy range from a 5.5 MV Van de Graaff accelerator, film thickness (in atoms/sq cm), stoichiometry, impurity concentration profiles, and crystalline structure were determined by Rutherford backscattering (RBS), high-energy backscattering, channeling, nuclear reaction analysis (NRA) and proton induced X-ray emission (PIXE). Most of these techniques are discussed in detail in the ODSC Annual Report (February 17, 1987), p. 74. The PIXE technique is briefly discussed in the ODSC Annual Report (March 15, 1991), p. 23.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vladimirsky, V. V.; Grigor'ev, V. K.; Erofeev, I. A.
2006-03-15
On the basis of experimental data from the 6-m spectrometer of the Institute of Theoretical and Experimental Physics (ITEP, Moscow), an amplitude analysis of 40 553 events of the reaction {pi}{sup -}p {sup {yields}} K{sub S}K{sub S}n induced by a negatively charged pion of energy 40 GeV is performed over a broad momentum transfer range by using a new procedure. The results for vertical bar t vertical bar > 0.1 GeV{sup 2} are obtained for the first time. In particular, resonances of mass 1700 and 1900 MeV and width 120 MeV are discovered in the D{sub +} wave (there weremore » no such resonances for vertical bar t vertical bar < 0.1 GeV{sup 2}). In the region of low momentum transfers, the S wave exhibits a structure that lies in the mass region around 1370 MeV and which requires three resonances for its explanation. Two of these (that of mass 1234 {+-} 6 MeV and width 47 {+-} 33 MeV and that of mass 1478 {+-} 6 MeV and width 119 {+-} 10 MeV) were found in the studies of A. Etkin et al. [Phys. Rev. D 25, 2446 (1982)] and O.N. Baloshin et al. {l_brace}Yad. Fiz. 43, 1487 (1986) [Phys. At. Nucl. 43, 959 (1986)]{r_brace}. The third has a mass of 1389 {+-} 9 MeV and a width of 30 {+-} 24 MeV. At high momentum transfers, the S wave is found to feature resonances that have the following parameters: M = 1328 {+-} 8 MeV and {gamma} = 237 {+-} 20 MeV, M = 1440 {+-} 6 MeV and {gamma} = 121 {+-} 15 MeV, and M = 1776 {+-} 15 MeV and {gamma} 250 {+-} 30 MeV. For the D{sub 0} wave, it is found that, in addition to the well-known resonances f{sub 2}, a{sub 2}, and f'{sub 2}, there appear the following resonances in this wave: a resonance of mass 2005 {+-} 12 MeV and width 209 {+-} 32 MeV and a resonance of mass 2270 {+-} 12 MeV and width 90 {+-} 29 MeV at low vertical bar t vertical bar and a resonance of mass 1659 {+-} 6 and width 152 {+-} 18 and a resonance of mass 2200 {+-} 13 MeV and width 91 {+-} 62 MeV at high vertical bar t vertical bar.« less
An analysis of MCNP cross-sections and tally methods for low-energy photon emitters.
Demarco, John J; Wallace, Robert E; Boedeker, Kirsten
2002-04-21
Monte Carlo calculations are frequently used to analyse a variety of radiological science applications using low-energy (10-1000 keV) photon sources. This study seeks to create a low-energy benchmark for the MCNP Monte Carlo code by simulating the absolute dose rate in water and the air-kerma rate for monoenergetic point sources with energies between 10 keV and 1 MeV. The analysis compares four cross-section datasets as well as the tally method for collision kerma versus absorbed dose. The total photon attenuation coefficient cross-section for low atomic number elements has changed significantly as cross-section data have changed between 1967 and 1989. Differences of up to 10% are observed in the photoelectric cross-section for water at 30 keV between the standard MCNP cross-section dataset (DLC-200) and the most recent XCOM/NIST tabulation. At 30 keV, the absolute dose rate in water at 1.0 cm from the source increases by 7.8% after replacing the DLC-200 photoelectric cross-sections for water with those from the XCOM/NIST tabulation. The differences in the absolute dose rate are analysed when calculated with either the MCNP absorbed dose tally or the collision kerma tally. Significant differences between the collision kerma tally and the absorbed dose tally can occur when using the DLC-200 attenuation coefficients in conjunction with a modern tabulation of mass energy-absorption coefficients.
New analysis of ηπ tensor resonances measured at the COMPASS experiment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jackura, A.; Fernández-Ramírez, C.; Mikhasenko, M.
We presenmore » t a new amplitude analysis of the ηπ D-wave in the reaction π - p → η π - p measured by COMPASS. Employing an analytical model based on the principles of the relativistic S-matrix, we find two resonances that can be identified with the a 2 ( 1320 ) and the excited a 2 ' ( 1700 ) , and perform a comprehensive analysis of their pole positions. For the mass and width of the a 2 we find M = ( 1307 ± 1 ± 6 ) MeV and Γ = ( 112 ± 1 ± 8 ) MeV, and for the excited state a 2 ' we obtain M = ( 1720 ± 10 ± 60 ) MeV and Γ = ( 280 ± 10 ± 70 ) MeV, respectively.« less
New analysis of ηπ tensor resonances measured at the COMPASS experiment
Jackura, A.; Fernández-Ramírez, C.; Mikhasenko, M.; ...
2018-02-27
We presenmore » t a new amplitude analysis of the ηπ D-wave in the reaction π - p → η π - p measured by COMPASS. Employing an analytical model based on the principles of the relativistic S-matrix, we find two resonances that can be identified with the a 2 ( 1320 ) and the excited a 2 ' ( 1700 ) , and perform a comprehensive analysis of their pole positions. For the mass and width of the a 2 we find M = ( 1307 ± 1 ± 6 ) MeV and Γ = ( 112 ± 1 ± 8 ) MeV, and for the excited state a 2 ' we obtain M = ( 1720 ± 10 ± 60 ) MeV and Γ = ( 280 ± 10 ± 70 ) MeV, respectively.« less
Measurement Over Large Solid Angle of Low Energy Cosmic Ray Muon Flux
NASA Astrophysics Data System (ADS)
Schreiner, H. F., III; Schwitters, R. F.
2015-12-01
Recent advancements in portable muon detectors have made cosmic ray imaging practical for many diverse applications. Working muon attenuation detectors have been built at the University of Texas and are already successfully being used to image tunnels, structures, and Mayan pyramids. Most previous studies have focused on energy measurements of the cosmic ray spectrum from of 1 GeV or higher. We have performed an accurate measurement of the ultra-low energy (<2 GeV in E cos θ) muon spectrum down to the acceptance level of our detector, around one hundred MeV. Measurements include angular dependence, with acceptance approaching horizontal. Measurements were made underwater using a custom enclosure in Lake Travis, Austin, TX. This measurement will allow more accurate predictions and simulations of attenuation for small (<5 m) targets for muon tomography.
NASA Astrophysics Data System (ADS)
Dooraghi, Alex A.; Tringe, Joseph W.
2018-04-01
To evaluate conventional munition, we simulated an x-ray computed tomography (CT) system for generating radiographs from nominal x-ray energies of 6 or 9 megaelectron volts (MeV). CT simulations, informed by measured data, allow for optimization of both system design and acquisition techniques necessary to enhance image quality. MCNP6 radiographic simulation tools were used to model ideal detector responses (DR) that assume either (1) a detector response proportional to photon flux (N) or (2) a detector response proportional to energy flux (E). As scatter may become significant with MeV x-ray systems, simulations were performed with and without the inclusion of object scatter. Simulations were compared against measurements of a cylindrical munition component principally composed of HMX, tungsten and aluminum encased in carbon fiber. Simulations and measurements used a 6 MeV peak energy x-ray spectrum filtered with 3.175 mm of tantalum. A detector response proportional to energy which includes object scatter agrees to within 0.6 % of the measured line integral of the linear attenuation coefficient. Exclusion of scatter increases the difference between measurement and simulation to 5 %. A detector response proportional to photon flux agrees to within 20 % when object scatter is included in the simulation and 27 % when object scatter is excluded.
NASA Technical Reports Server (NTRS)
Hammond, E. C., Jr.; Peters, Kevin; Stober, AL
1984-01-01
The 2aO film, pre-exposed to a series of neutral density filters which on development under standard conditions will produce the standard H-D curve for that film, were then exposed to Alpha paricles with a dose range of 3/10ths rads to 8 rads while varying the energy of the particles using 153 MeV, 70 MeV, and 47 MeV, respectively. An analysis of the film shows that the 3/10th rad dose produces the lowest optical density changes at 70 MeV and 47 MeV. While the optical density readings for the darker patterns seem to oscillate and decrease when exposed to radiation dosages of 3/10th rads to 8 rads.
NASA Astrophysics Data System (ADS)
Sharaf, J. M.; Saleh, H.
2015-05-01
The shielding properties of three different construction styles, and building materials, commonly used in Jordan, were evaluated using parameters such as attenuation coefficients, equivalent atomic number, penetration depth and energy buildup factor. Geometric progression (GP) method was used to calculate gamma-ray energy buildup factors of limestone, concrete, bricks, cement plaster and air for the energy range 0.05-3 MeV, and penetration depths up to 40 mfp. It has been observed that among the examined building materials, limestone offers highest value for equivalent atomic number and linear attenuation coefficient and the lowest values for penetration depth and energy buildup factor. The obtained buildup factors were used as basic data to establish the total equivalent energy buildup factors for three different multilayer construction styles using an iterative method. The three styles were then compared in terms of fractional transmission of photons at different incident photon energies. It is concluded that, in case of any nuclear accident, large multistory buildings with five layers exterior walls, style A, could effectively attenuate radiation more than small dwellings of any construction style.
The host galaxy and Fermi -LAT counterpart of HESS J1943+213
Peter, D.; Domainko, W.; Sanchez, D. A.; ...
2014-11-06
The very-high energy (VHE, E> 100 GeV) gamma-ray sky shows diverse Galactic and extragalactic source populations. For some sources the astrophysical object class could not be identified so far. The nature (Galactic or extragalactic) of the VHE gamma-ray source HESS J1943+213 is explored. We specifically investigate the proposed near-infrared counterpart 2MASS J19435624+2118233 of HESS J1943+213 and investigate the implications of a physical association. We present K-band imaging from the 3.5 m CAHA telescope of 2MASS J19435624+2118233. Furthermore, 5 years of Fermi-LAT data were analyzed to search for a high-energy (HE, 100 MeV stat ± 0.6 sys) × 10 -15 cmmore » -2 s -1 MeV -1 at the decorrelation energy Edec = 15.1 GeV and a spectral index of Γ = 1.59 ± 0.19stat ± 0.13sys. This gamma-ray spectrum shows a rather sharp break between the HE and VHE regimes of ΔΓ = 1.47 ± 0.36. In conclusion, the infrared and HE data strongly favor an extragalactic origin of HESS J1943+213, where the infrared counterpart traces the host galaxy of an extreme blazar and where the rather sharp spectral break between the HE and VHE regime indicates attenuation on extragalactic background light. The source is most likely located at a redshift between 0.03 and 0.45 according to extension and EBL attenuation arguments.« less
Energy dependence of SEP electron and proton onset times
NASA Astrophysics Data System (ADS)
Xie, H.; Mäkelä, P.; Gopalswamy, N.; St. Cyr, O. C.
2016-07-01
We study the large solar energetic particle (SEP) events that were detected by GOES in the >10 MeV energy channel during December 2006 to March 2014. We derive and compare solar particle release (SPR) times for the 0.25-10.4 MeV electrons and 10-100 MeV protons for the 28 SEP events. In the study, the electron SPR times are derived with the time-shifting analysis (TSA) and the proton SPR times are derived using both the TSA and the velocity dispersion analysis (VDA). Electron anisotropies are computed to evaluate the amount of scattering for the events under study. Our main results include (1) near-relativistic electrons and high-energy protons are released at the same time within 8 min for most (16 of 23) SEP events. (2)There exists a good correlation between electron and proton acceleration, peak intensity, and intensity time profiles. (3) The TSA SPR times for 90.5 MeV and 57.4 MeV protons have maximum errors of 6 min and 10 min compared to the proton VDA release times, respectively, while the maximum error for 15.4 MeV protons can reach to 32 min. (4) For 7 low-intensity events of the 23, large delays occurred for 6.5 MeV electrons and 90.5 MeV protons relative to 0.5 MeV electrons. Whether these delays are due to times needed for the evolving shock to be strengthened or due to particle transport effects remains unsolved.
NASA Technical Reports Server (NTRS)
Krause, L. Habsh; Gilchrist, B. E.; Nishikawa, Ken-Ichi
2013-01-01
Relativisitic electron precipitation (REP) events occur when beams or bunches of relativistic electrons of magnetospheric origin enter the Earth's atmosphere, typically at auroral latitudes. REP events are associated with a variety of space weather effects, including production of transitional and bremsstrahlung radiation, catalytic depletion of stratospheric ozone, and scintillation of transionospheric radio waves. This study examines the intensities of x-rays produced at airliner, manned balloon, and space reuseable launch vehicles (sRLVs). The monoenergetic beam is modeled in cylindrical symetry using the paraxial ray equation. Bremsstrahlung photon production is calculated using the traditional Sauter-Elwert cross-section, providing x-ray emission spectra differential in energy and angle. Attenuation is computed for a plane-stratified standard atmosphere, and the loss processes include photoionization, Rayleigh and Compton scattering, electron-positron pair production, and photonuclear interaction. Peak altitudes of electron energy deposition and bremsstrahlung x-ray production were calculated for beams of energies from 1 MeV through 100 MeV. The altitude peak of bremsstrahlung deposition was consistently and significantly lower that that of the electron deposition due to the longer mean free paths of x-rays compared to electrons within the atmosphere. For example, for a nadir-directed monoenergetic 5 MeV beam, the peak deposition altitude was calculated to be 42 km, but the resulting bremsstrahlung deposition peaked at 25 km. This has implications for crew and passenger safety, especially with the growth of the space tourism industry. A survey of results covering the 1-100 MeV spectrum for the three altitude ranges of interest will be presented.
Zeinali-Rafsanjani, B; Faghihi, R; Mosleh-Shirazi, M A; Saeedi-Moghadam, M; Jalli, R; Sina, S
2018-01-01
MRI-only treatment planning (TP) can be advantageous in paediatric radiotherapy. However, electron density extraction is necessary for dose calculation. Normally, after bone segmentation, a bulk density is assigned. However, the variation of bone bulk density in patients makes the creation of pseudo CTs challenging. This study aims to assess the effects of bone density variations in children on radiation attenuation and dose calculation for MRI-only TP. Bone contents of <15-year-old children were calculated, and substituted in the Oak Ridge National Laboratory paediatric phantoms. The percentage depth dose and beam profile of 150 kVp and 6 MV photon and 6 MeV electron beams were then calculated using Xcom, MCNPX (Monte Carlo N-particle version X) and ORLN phantoms. Using 150 kVp X-rays, the difference in attenuation coefficient was almost 5% between an 11-year-old child and a newborn, and ~8% between an adult and a newborn. With megavoltage radiation, the differences were smaller but still important. For an 18 MV photon beam, the difference of radiation attenuation between an 11-year-old child and a newborn was 4% and ~7.4% between an adult and a newborn. For 6 MeV electrons, dose differences were observed up to the 2 cm depth. The percentage depth dose difference between 1 and 10-year-olds was 18.5%, and between 10 and 15-year-olds was 24%. The results suggest that for MRI-only TP of photon- or electron-beam radiotherapy, the bone densities of each age group should be defined separately for accurate dose calculation. Advances in knowledge: This study highlights the need for more age-specific determination of bone electron density for accurate dose calculations in paediatric MRI-only radiotherapy TP.
Experimental check of bremsstrahlung dosimetry predictions for 0.75 MeV electrons
NASA Astrophysics Data System (ADS)
Sanford, T. W. L.; Halbleib, J. A.; Beezhold, W.
Bremsstrahlung dose in CaF2 TLDs from the radiation produced by 0.75 MeV electrons incident on Ta/C targets is measured and compared with that calculated via the CYLTRAN Monte Carlo code. The comparison was made to validate the code, which is used to predict and analyze radiation environments of flash X-ray simulators measured by TLDs. Over a wide range of Ta target thicknesses and radiation angles the code is found to agree with the 5% measurements. For Ta thickness near those that optimize the radiation output, however, the code overestimates the radiation dose at small angles. Maximum overprediction is about 14 + or - 5%. The general agreement, nonetheless, gives confidence in using the code at this energy and in the TLD calibration procedure. For the bulk of the measurements, a standard TLD employing a 2.2 mm thick Al equilibrator was used. In this paper we also show that this thickness can significantly attenuate the free-field dose and introduces significant photon buildup in the equalibrator.
Zhang, Hai-Bo; Zhang, Xiang-Liang; Wang, Yong; Takaoka, Akio
2007-01-01
The possibility of utilizing high-energy electron tomography to characterize the micron-scale three dimensional (3D) structures of integrated circuits has been demonstrated experimentally. First, electron transmission through a tilted SiO(2) film was measured with an ultrahigh-voltage electron microscope (ultra-HVEM) and analyzed from the point of view of elastic scattering of electrons, showing that linear attenuation of the logarithmic electron transmission still holds valid for effective specimen thicknesses up to 5 microm under 2 MV accelerating voltages. Electron tomography of a micron-order thick integrated circuit specimen including the Cu/via interconnect was then tried with 3 MeV electrons in the ultra-HVEM. Serial projection images of the specimen tilted at different angles over the range of +/-90 degrees were acquired, and 3D reconstruction was performed with the images by means of the IMOD software package. Consequently, the 3D structures of the Cu lines, via and void, were revealed by cross sections and surface rendering.
Beta reduction factors for protective clothing at the Oak Ridge National Laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Franklin, G.L.; Gonzalez, P.L.
1998-12-31
Beta reduction factors (f{sub {beta}}) for protective clothing (PC) at the Oak Ridge National Laboratory (ORNL) have been determined for a variety of protective clothing combinations. Data was collected to determine the experimental f{sub {beta}} for several combinations of PCs under laboratory conditions. Radiation dose rates were measured with an open window Bicron{reg_sign} RSO-5 ion chamber for two distinct beta energy groups (E{sub max} = 1.218 {times} 10{sup {minus}13} J(0.860 MeV) and 3.653 {times} 10{sup {minus}13} J (2.280 MeV)). Data points determined, as the ratio of unattenuated (no PCs) to attenuated (PCs), were used to derive a set of equationsmore » using the Microsoft{reg_sign} Excel Linet function. Field comparison tests were then conducted to determine the validity of these beta reduction factors. The f{sub {beta}} from the field tests were significantly less than the experimental f{sub {beta}}, indicating that these factors will yield conservative results.« less
NASA Astrophysics Data System (ADS)
Lokhande, Rajkumar M.; More, Chaitali V.; Surung, Bharat S.; Pawar, Pravina P.
2017-12-01
We have computed radiological parameters of some C- H- N- O based amine group bio material in the energy range 122-1330 keV with the gamma ray count by narrow beam geometry. The NaI(Tl) detector with 8 K multichannel analyser was used having resolution 6.8% at 663 keV. The energy absorption buildup factor (EABF) was determined by using Geometric Progression (G-P) fitting method up to penetration depth of 40 mfp at energy 0.015-15 MeV. The NIST XCOM data were compared with the experimental value and we observed (3-5%) difference. The comparative study of effective atomic number and effective electron density in the energy range 122-1330 keV using Gaussian fit for accuracy were performed. The amino acid has the highest EABF value at 0.1 MeV and the variation in EABF with penetration depth up to 1-40 mean free path (mfp). The calculated radiological data of biological material are applicable in medical physics and dosimetry.
SPECTRAL ANALYSIS OF FERMI -LAT BLAZARS ABOVE 50 GEV
Domínguez, Alberto; Ajello, Marco
2015-11-04
We present an analysis of the intrinsic (unattenuated by the extragalactic background light, EBL) power-law spectral indices of 128 extragalactic sources detected up to z ~ 2 with the Fermi-Large Area Telescope (LAT) at very high energies (VHEs, E ≥50 GeV). The median of the intrinsic index distribution is 2.20 (versus 2.54 for the observed distribution). We also analyze the observed spectral breaks (i.e., the difference between the VHE and high energy, HE, 100 MeV ≤ E ≤ 300 GeV, spectral indices). The Fermi-LAT has now provided a large sample of sources detected both at VHE and HE with comparablemore » exposure that allows us to test models of extragalactic γ-ray photon propagation. We find that our data are compatible with simulations that include intrinsic blazar curvature and EBL attenuation. There is also no evidence of evolution with redshift of the physics that drives the photon emission in high-frequency synchrotron peak (HSP) blazars. This makes HSP blazars excellent probes of the EBL.« less
NASA Astrophysics Data System (ADS)
Murata, Isao; Ohta, Masayuki; Miyamaru, Hiroyuki; Kondo, Keitaro; Yoshida, Shigeo; Iida, Toshiyuki; Ochiai, Kentaro; Konno, Chikara
2011-10-01
Nuclear data are indispensable for development of fusion reactor candidate materials. However, benchmarking of the nuclear data in MeV energy region is not yet adequate. In the present study, benchmark performance in the MeV energy region was investigated theoretically for experiments by using a 14 MeV neutron source. We carried out a systematical analysis for light to heavy materials. As a result, the benchmark performance for the neutron spectrum was confirmed to be acceptable, while for gamma-rays it was not sufficiently accurate. Consequently, a spectrum shifter has to be applied. Beryllium had the best performance as a shifter. Moreover, a preliminary examination of whether it is really acceptable that only the spectrum before the last collision is considered in the benchmark performance analysis. It was pointed out that not only the last collision but also earlier collisions should be considered equally in the benchmark performance analysis.
Analysis of Proton Radiation Effects on Gallium Nitride High Electron Mobility Transistors
2017-03-01
energy levels on a GaN-on-silicon high electron mobility transistor was created. Based on physical results of 2.0-MeV protons irradiation to fluence...and the physical device at 2.0-MeV proton irradiation , predictions were made for 5.0, 10.0, 20.0 and 40.0-MeV proton irradiation . The model generally...nitride, high electron mobility transistor, electronics, 2 MeV proton irradiation , radiation effects 15. NUMBER OF PAGES 87 16. PRICE CODE 17. SECURITY
Compositional, structural, and optical changes of polyimide implanted by 1.0 MeV Ni+ ions
NASA Astrophysics Data System (ADS)
Mikšová, R.; Macková, A.; Pupikova, H.; Malinský, P.; Slepička, P.; Švorčík, V.
2017-09-01
The ion irradiation leads to deep structural and compositional changes in the irradiated polymers. Ni+ ions implanted polymers were investigated from the structural and compositional changes point of view and their optical properties were investigated. Polyimide (PI) foils were implanted with 1.0 MeV Ni+ ions at room temperature with fluencies of 1.0 × 1013-1.0 × 1015 cm-2 and two different ion implantation currents densities (3.5 and 7.2 nA/cm2). Rutherford Back-Scattering (RBS) and Elastic Recoil Detection Analysis (ERDA) were used for determination of oxygen and hydrogen escape in implanted PI. Atomic Force Microscopy (AFM) was used to follow surface roughness modification after the ion implantation and UV-Vis spectroscopy was employed to check the optical properties of the implanted PI. The implanted PI structural changes were analysed using Attenuated Total Reflection Fourier Transform Infrared Spectroscopy (ATR-FTIR). High energy Ni-ion implantation causes only a minor release of hydrogen and oxygen close to the polymer sub-surface region in about 60 nm thick layer penetrated by the ion beam; especially at ion fluencies below 1.0 × 1014 cm-2. The mostly pronounced structural changes of the Ni implanted PI were found for the samples implanted above ion fluence 1.0 × 1015 cm-2 and at the ion current density 7.2 nA/cm2, where the optical band gap significantly decreases and the reduction of more complex structural unit of PI monomer was observed.
NASA Astrophysics Data System (ADS)
Elbashir, B. O.; Dong, M. G.; Sayyed, M. I.; Issa, Shams A. M.; Matori, K. A.; Zaid, M. H. M.
2018-06-01
The mass attenuation coefficients (μ/ρ), effective atomic numbers (Zeff) and electron densities (Ne) of some amino acids obtained experimentally by the other researchers have been calculated using MCNP5 simulations in the energy range 0.122-1.330 MeV. The simulated values of μ/ρ, Zeff, and Ne were compared with the previous experimental work for the amino acids samples and a good agreement was noticed. Moreover, the values of mean free path (MFP) for the samples were calculated using MCNP5 program and compared with the theoretical results obtained by XCOM. The investigation of μ/ρ, Zeff, Ne and MFP values of amino acids using MCNP5 simulations at various photon energies when compared with the XCOM values and previous experimental data for the amino acids samples revealed that MCNP5 code provides accurate photon interaction parameters for amino acids.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Depuydt, H.
1958-02-25
The beta spectra of Au/sup 198/, In/sup 114/ P/sup 32/, Y/sup 90/, and Cs/sup 137/ were determined with a scintillation counter (anthracene crystal) and an amplitude selector. The conversion electron peak of Cs/sup 137/ was used for the determination of the pulse-height energy calibration line. The maximum beta energy was determined by means of a Fermi-Curie analysis of the spectra, and the results were 0.928 plus or minus 0.05 Mev for Au/sup 198/, 2.10 plus or minus 0.02 Mev for In/sup 114/, 1/703 plus or minus 0.018 Mev for P/sup 32/, 2.42 plus or minus 0.02 Mev for Y/sup 90/,more » and 0.522 plus or minus 0.010 and 1.28 plus or minus 0.31 Mev for Cs/sup 137/. The maximum beta energy determination was made by means of the absorption curve to which the Feather analysis was applied (the absorption curve of P/sup 32/ serving as a standard). The results were 0.947 Mev for Au/sup 198/ and 2.02 Mev for In/sup 114/ . (tr-auth)« less
NASA Astrophysics Data System (ADS)
Iwamoto, C.; Utsunomiya, H.; Tamii, A.; Akimune, H.; Nakada, H.; Shima, T.; Yamagata, T.; Kawabata, T.; Fujita, Y.; Matsubara, H.; Shimbara, Y.; Nagashima, M.; Suzuki, T.; Fujita, H.; Sakuda, M.; Mori, T.; Izumi, T.; Okamoto, A.; Kondo, T.; Bilgier, B.; Kozer, H. C.; Lui, Y.-W.; Hatanaka, K.
2012-06-01
A high-resolution measurement of inelastic proton scattering off Zr90 near 0° was performed at 295 MeV with a focus on a pronounced strength previously reported in the low-energy tail of giant dipole resonance. A forest of fine structure was observed in the excitation energy region 7-12 MeV. A multipole decomposition analysis of the angular distribution for the forest was carried out using the ECIS95 distorted-wave Born approximation code with the Hartree-Fock plus random-phase approximation model of E1 and M1 transition densities and inclusion of E1 Coulomb excitation. The analysis separated pygmy dipole and M1 resonances in the forest at EPDR=9.15±0.18MeV with ΓPDR=2.91±0.64MeV and at EM1=9.53±0.06MeV with ΓM1=2.70±0.17MeV in the Lorentzian function, respectively. The B(E1)↑ value for pygmy dipole resonance over 7-11 MeV is 0.75±0.08e2fm2, which corresponds to 2.1±0.2% of the Thomas-Reiche-Kuhn sum rule.
Paudel, M; MacKenzie, M; Fallone, B; Rathee, S
2012-06-01
To evaluate the performance of a model based image reconstruction in reducing metal artifacts in MVCT systems, and to compare with filtered-back projection (FBP) technique. Iterative maximum likelihood polychromatic algorithm for CT (IMPACT) is used with pair/triplet production process and the energy dependent response of detectors. The beam spectra for in-house bench-top and TomotherapyTM MVCT are modelled for use in IMPACT. The energy dependent gain of detectors is calculated using a constrained optimization technique and measured attenuation produced by 0 - 24 cm thick solid water slabs. A cylindrical (19 cm diameter) plexiglass phantom containing various central cylindrical inserts (relative electron density of 0.28-1.69) between two steel rods (2 cm diameter) is scanned in the bench-top [the bremsstrahlung radiation from 6 MeV electron beam passed through 4 cm solid water on the Varian Clinac 2300C] and TomotherapyTM MVCTs. The FBP reconstructs images from raw signal normalised to air scan and corrected for beam hardening using a uniform plexi-glass cylinder (20 cm diameter). IMPACT starts with FBP reconstructed seed image and reconstructs final image at 1.25 MeV in 150 iterations. FBP produces a visible dark shading in the image between two steel rods that becomes darker with higher density central insert causing 5-8 % underestimation of electron density compared to the case without the steel rods. In the IMPACT image the dark shading connecting the steel rods is nearly removed and the uniform background restored. The average attenuation coefficients of the inserts and the background are very close to the corresponding theoretical values at 1.25 MeV. The dark shading metal artifact due to beam hardening can be removed in MVCT using the iterative reconstruction algorithm such as IMPACT. However, the accurate modelling of detectors' energy dependent response and physical processes are crucial for successful implementation. Funding support for the research is obtained from "Vanier Canada Graduate Scholarship" and "Canadian Institute of Health Research". © 2012 American Association of Physicists in Medicine.
Neutron elastic and inelastic cross section measurements for 28Si
NASA Astrophysics Data System (ADS)
Derdeyn, E. C.; Lyons, E. M.; Morin, T.; Hicks, S. F.; Vanhoy, J. R.; Peters, E. E.; Ramirez, A. P. D.; McEllistrem, M. T.; Mukhopadhyay, S.; Yates, S. W.
2017-09-01
Neutron elastic and inelastic cross sections are critical for design and implementation of nuclear reactors and reactor equipment. Silicon, an element used abundantly in fuel pellets as well as building materials, has little to no experimental cross sections in the fast neutron region to support current theoretical evaluations, and thus would benefit from any contribution. Measurements of neutron elastic and inelastic differential scattering cross sections for 28Si were performed at the University of Kentucky Accelerator Laboratory for incident neutron energies of 6.1 MeV and 7.0 MeV. Neutrons were produced by accelerated deuterons incident on a deuterium gas cell. These nearly mono-energetic neutrons then scattered off a natural Si sample and were detected using liquid deuterated benzene scintillation detectors. Scattered neutron energy was deduced using time-of-flight techniques in tandem with kinematic calculations for an angular distribution. The relative detector efficiency was experimentally determined over a neutron energy range from approximately 0.5 to 7.75 MeV prior to the experiment. Yields were corrected for multiple scattering and neutron attenuation in the sample using the forced-collision Monte Carlo correction code MULCAT. Resulting cross sections will be presented along with comparisons to various data evaluations. Research is supported by USDOE-NNSA-SSAP: NA0002931, NSF: PHY-1606890, and the Donald A. Cowan Physics Institute at the University of Dallas.
NASA Astrophysics Data System (ADS)
Habash Krause, L.; Gilchrist, B. E.; Nishikawa, K.; Williams, A.
2013-12-01
Relativistic electron precipitation (REP) events occur when beams or bunches of relativistic electrons of magnetospheric origin enter the Earth's atmosphere, typically at auroral latitudes. REP events are associated with a variety of space weather effects, including production of transitional and bremsstrahlung radiation, catalytic depletion of stratospheric ozone, and scintillation of transionospheric radio waves. This study examines the intensities of x-rays produced at airliner, manned balloon, and suborbital Reusable Launch Vehicle (sRLV) altitudes. The monoenergetic beam is modeled in cylindrical symmetry using the paraxial ray equation. Bremsstrahlung photon production is calculated using the traditional Sauter-Elwert cross-section, providing x-ray emission spectra differential in energy and angle. Attenuation is computed for a plane-stratified standard atmosphere, and the loss processes include photoionization, Rayleigh and Compton scattering, electron-positron pair production, and photonuclear interaction. Peak altitudes of electron energy deposition and bremsstrahlung x-ray production were calculated for beams of energies from 1 MeV through 100 MeV. The altitude peak of bremsstrahlung deposition was consistently and significantly lower that that of the electron deposition due to the longer mean free paths of x-rays compared to electrons within the atmosphere. For example, for a nadir-directed monoenergetic 5 MeV beam, the peak deposition altitude was calculated to be 42 km, but the resulting bremmstrahlung deposition peaked at 25 km. This has implications for crew and passenger safety, especially with the growth of the space tourism industry that relies on sRLVs with a nominal apogee of 100 km. A survey of results covering the 1-100 MeV spectrum for the three altitude ranges of interest will be presented.
Analysis and verification of a prediction model of solar energetic proton events
NASA Astrophysics Data System (ADS)
Wang, J.; Zhong, Q.
2017-12-01
The solar energetic particle event can cause severe radiation damages near Earth. The alerts and summary products of the solar energetic proton events were provided by the Space Environment Prediction Center (SEPC) according to the flux of the greater than 10 MeV protons taken by GOES satellite in geosynchronous orbit. The start of a solar energetic proton event is defined as the time when the flux of the greater than 10 MeV protons equals or exceeds 10 proton flux units (pfu). In this study, a model was developed to predict the solar energetic proton events, provide the warning for the solar energetic proton events at least minutes in advance, based on both the soft X-ray flux and integral proton flux taken by GOES. The quality of the forecast model was measured against verifications of accuracy, reliability, discrimination capability, and forecast skills. The peak flux and rise time of the solar energetic proton events in the six channels, >1MeV, >5 MeV, >10 MeV, >30 MeV, >50 MeV, >100 MeV, were also simulated and analyzed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fontainha, C.C.P.; Nolasco, A.V.; Santos, A.P.
Radiation dosimetry is commonly used to prevent deterministic radiation effects in high dose medical procedures. Radiochromic films find nowadays widely application in radiotherapy, interventional procedures and CT exams for isodose and maximum skin dose measurements. Moreover the size of the irradiated area and its distribution can be performed through the reading of the individual components in the RGB-spectrum. Particularly, radiochromic film has multiple advantages over alternative dosimeters for low-kV X-rays dosimetry. Concerned to spatial resolution it is far superior to that of ionization chambers and thermoluminescent dosimeters. For high energy photon fields (keV to MeV) the most used radiochromic filmmore » commercially available belongs to the EBT Gafchromic{sup R} series. On the other hand, for low energy photon fields in the x-ray range (20 kVp to 200 kVp) the best choice belongs to the XR-QA Gafchromic{sup R} film series. In this work we demonstrate the possibility of generating 2D images of thin polymeric composites films using EBT3 and XR-QA2 Gafchromic{sup R} films exposed to 6 MeV and 40 keV x-ray photons, respectively, using the digital filtering tools of the ImageJ{sup R} free software. In this context, EBT3 films were placed on the surface of a rigid anthropomorphic phantom. Then, they were covered with a thermoplastic mask made of PCL polymer. This setup was then exposed to 2.0 Gy absorbed dose in the Linear Accelerator beam. The EBT3 films were then scanned in the high resolution mode in a commercial scanner and the images subsequently treated with digital filters. It is somehow possible to see the image of the thermoplastic mask in the scanned image. However, in the treated image it is easy to observe the mask arrangement. The unexpected phenomenon here is the EB3 film ability to detect the attenuation of high energy photons by a plastic material, which in turn has a very low mass-energy attenuation coefficient, producing a very clear 2D image. This result is discussed in terms of the high Z halides added to the sensitive layer of EB3 film, once the main components are C (42.3%), H (39.7%) and O (16.0%)1-2. Based on the above results, we have speculated about the abilities of XR-AQ films in the detection of the distribution of nano-sized particles that has high mass-energy attenuation coefficients for low energy x-rays, in polymer composites. In another investigation we tested the ability of XR-QA2 Gafchromic{sup R} films to evaluate the dispersion of ZrO{sub 2} nano-sized grain clusters in protective composites. The P(VDFTrFE)/ ZrO{sub 2} film was sandwiched between two XR-QA2 radiochromic films. In this setup, one radiochromic film is directly exposed to 100 mGy of the x-rays beam and another one measures the attenuated beam. After storage for 24 hours at room temperature under no light conditions, the irradiated radiochromic films were scanned under the same conditions in order to obtain a more reliable result. All films were scanned using the same size ROI in high resolution mode and saved as tagged image file format (TIFF). The untreated scanned image of the XR-AQ2 film directed exposed to the X-ray beam and the correspondent treated image with digital filters are shown. The untreated and treated image of the XR-AQ2 film that was exposed to the attenuated x-ray beam is shown. The image treated with digital filters seems to reproduce the dispersion of ZrO{sub 2} nano-sized grain clusters in the P(VDF-TrFE) copolymer matrix. This result is also discussed in terms of the high Z halides added to the sensitive layer of XR-AQ2 film and compared to the MEV images obtained from the P(VDF-TrFE)/ZrO{sub 2} composites. The results indicate a clear correlation between the 2D radiochromic image and the MEV photography.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tamura, K; Araki, F; Ohno, T
Purpose: To investigate the difference of dose distributions with/without the effect of inter-seed attenuation and tissue compositions in prostate {sup 125}I brachytherapy dose calculations, using Monte Carlo simulations of Particle and Heavy Ion Transport code System (PHITS). Methods: The dose distributions in {sup 125}I prostate brachytherapy were calculated using PHITS for non-simultaneous and simultaneous alignments of STM1251 sources in water or prostate phantom for six patients. The PHITS input file was created from DICOM-RT file which includes source coordinates and structures for clinical target volume (CTV) and organs at risk (OARs) of urethra and rectum, using in-house Matlab software. Photonmore » and electron cutoff energies were set to 1 keV and 100 MeV, respectively. The dose distributions were calculated with the kerma approximation and the voxel size of 1 × 1 × 1 mm{sup 3}. The number of incident photon was set to be the statistical uncertainty (1σ) of less than 1%. The effect of inter-seed attenuation and prostate tissue compositions was evaluated from dose volume histograms (DVHs) for each structure, by comparing to results of the AAPM TG-43 dose calculation (without the effect of inter-seed attenuation and prostate tissue compositions). Results: The dose reduction due to the inter-seed attenuation by source capsules was approximately 2% for CTV and OARs compared to those of TG-43. In additions, by considering prostate tissue composition, the D{sub 90} and V{sub 100} of CTV reduced by 6% and 1%, respectively. Conclusion: It needs to consider the dose reduction due to the inter-seed attenuation and tissue composition in prostate {sup 125}I brachytherapy dose calculations.« less
NASA Astrophysics Data System (ADS)
Yang, Yigang; Zhang, Zhi; Chen, Huaibi; Li, Yulan; Li, Yuanjing
2017-07-01
Contraband-detection systems can use X-rays and photoneutrons delivered from the same 7-MeV electron linear accelerator (e-LINAC) to stimulate and extract information from inspected materials. The X-ray attenuation information is used to measure the mass thickness, which is combined with the photoneutron attenuation information to categorize inspected materials as common organic materials, metals, and heavy metals. Once a heavy metal is found, the beta-delayed neutrons stimulated by the (γ,fission) reaction are measured by a polyethylene-moderated 3He counter to clarify if the material is fissile. The presence of neutron events 2000 μs after the X-ray pulse confirms the existence of the fissile material. The isotopes in the material are then identified using the time-of-flight method to analyze the resonant attenuation of the fissile material to the 10-1-102 eV photoneutrons emitted from and thermalized by the D2O photonto-neutron convertor, which converts X-rays to photoneutrons. Eight high-Z simulants are tested to confirm the feasibility of identifying the isotopes from the photoneutron resonance. The underlying principles and experimental results are discussed.
X-ray attenuation properties of stainless steel (u)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Lily L; Berry, Phillip C
2009-01-01
Stainless steel vessels are used to enclose solid materials for studying x-ray radiolysis that involves gas release from the materials. Commercially available stainless steel components are easily adapted to form a static or a dynamic condition to monitor the gas evolved from the solid materials during and after the x-ray irradiation. Experimental data published on the x-ray attenuation properties of stainless steel, however, are very scarce, especially over a wide range of x-ray energies. The objective of this work was to obtain experimental data that will be used to determine how a poly-energetic x-ray beam is attenuated by the stainlessmore » steel container wall. The data will also be used in conjunction with MCNP (Monte Carlos Nuclear Particle) modeling to develop an accurate method for determining energy absorbed in known solid samples contained in stainless steel vessels. In this study, experiments to measure the attenuation properties of stainless steel were performed for a range of bremsstrahlung x-ray beams with a maximum energy ranging from 150 keV to 10 MeV. Bremsstrahlung x-ray beams of these energies are commonly used in radiography of engineering and weapon components. The weapon surveillance community has a great interest in understanding how the x-rays in radiography affect short-term and long-term properties of weapon materials.« less
Elastic and inelastic scattering of neutrons from 56Fe
NASA Astrophysics Data System (ADS)
Ramirez, Anthony Paul; McEllistrem, M. T.; Liu, S. H.; Mukhopadhyay, S.; Peters, E. E.; Yates, S. W.; Vanhoy, J. R.; Harrison, T. D.; Rice, B. G.; Thompson, B. K.; Hicks, S. F.; Howard, T. J.; Jackson, D. T.; Lenzen, P. D.; Nguyen, T. D.; Pecha, R. L.
2015-10-01
The differential cross sections for elastic and inelastic scattered neutrons from 56Fe have been measured at the University of Kentucky Accelerator Laboratory (www.pa.uky.edu/accelerator) for incident neutron energies between 2.0 and 8.0 MeV and for the angular range 30° to 150°. Time-of-flight techniques and pulse-shape discrimination were employed for enhancing the neutron energy spectra and for reducing background. An overview of the experimental procedures and data analysis for the conversion of neutron yields to differential cross sections will be presented. These include the determination of the energy-dependent detection efficiencies, the normalization of the measured differential cross sections, and the attenuation and multiple scattering corrections. Our results will also be compared to evaluated cross section databases and reaction model calculations using the TALYS code. This work is supported by grants from the U.S. Department of Energy-Nuclear Energy Universities Program: NU-12-KY-UK-0201-05, and the Donald A. Cowan Physics Institute at the University of Dallas.
Flavor-singlet meson decay constants from Nf=2 +1 +1 twisted mass lattice QCD
NASA Astrophysics Data System (ADS)
Ottnad, Konstantin; Urbach, Carsten; ETM Collaboration
2018-03-01
We present an improved analysis of our lattice data for the η - η' system, including a correction of the relevant correlation functions for residual topological finite size effects and employing consistent chiral and continuum fits. From this analysis we update our physical results for the masses Mη=557 (11 )stat(03 )χ PT MeV and Mη'=911 (64 )stat(03 )χ PT MeV , as well as the mixing angle in the quark flavor basis ϕ =38.8 (2.2 )stat(2.4 )χPT ∘ in excellent agreement with other results from phenomenology. Similarly, we include an analysis for the decay constant parameters, leading to fl=125 (5 )stat(6 )χ PT MeV and fs=178 (4 )stat(1 )χ PT MeV . The second error reflects the uncertainty related to the chiral extrapolation. The data used for this study has been generated on gauge ensembles provided by the European Twisted Mass Collaboration with Nf=2 +1 +1 dynamical flavors of Wilson twisted mass fermions. These ensembles cover a range of pion masses from 220 MeV to 500 MeV and three values of the lattice spacing. Combining our data with a prediction from chiral perturbation theory, we give an estimate for the physical η , η'→γ γ decay widths and the singly-virtual η , η'→γ γ* transition form factors in the limit of large momentum transfer.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kawashima, K.; Takaku, Y.; Inada, T.
1961-01-01
A tissue-equivalent material was constructed from the following components: polyethylene (CH/sub 2/)/sub n/, 71.4% (by weight), NaNO/sub 3/ 21.3%, Al/sub 2/O/sub 3/ 5.5%, and TiC/sub 2/ 1.8%. The attenuation coefficients of this solid compound, Mix. p in x or gamma rays (40kev --1.25 Mev), were shown to be equal to those of a section of pork loin (m. longissimus dorsi). Thus, Mix. p is concluded to be good phantom material for depth dose measuremeat and suitable material for walls of ionizatlon chambers. (Abstr. Japan Med., 2: No. 3, March 1962)
García-Tello, A; Angulo, J C; Rodriguez-Ubreva, J; Andrés, G; López, J I; Sánchez-Chapado, M; López-Ruiz, P; Colás, B
2014-09-01
To study prostate and seminal vesicle anatomy in viable motheaten (mev) with mutations in PTPN6 gene leading to a severe reduction in the activity of protein tyrosine phosphatase SHP-1. Homozygous mev mice exhibit multiple anomalies that include immunodeficiencies, increased proliferation of macrophage, neutrophil, and erythrocyte progenitors, decreased bone density and sterility. We analyzed macro- and microscopic anatomy of the seminal vesicle and prostate macro- and microscopic anatomy of 5 mev/mev and 8 wt/wt adult 7 week old mice. Computerized morphometric analysis was performed to measure the relative changes appearing in the epithelial volume of the different prostatic lobes. All mice studied revealed normal genital organs (penis, testis, epididymis, vas deferens) and bladder. The seminal vesicle was absent in all mev/mev individuals analyzed, being normal and very noticeable in wt/wt mice. The different glands that compose the prostatic complex (anterior, ventral and dorso-lateral prostate) were atrophied in mev/mev mice: anterior prostate 0.4 times, ventral 0.19 times, dorsal 0.35 times and lateral 0.28 times those of the respective regions in wt/wt mice. Microscopically, mev/mev mice revealed scarce and large prostatic ducts, acini severely atrophic with empty lumen and scarce loose epithelial component forming tufts and infoldings, and hyperplastic changes in fibromuscular stroma. The prostate of mev/mev mice exhibits signs of aberrant differentiation and the resulting phenotype may be related to the loss of function of SHP-1. Prostatic anomalies in these mice affect, together with defects in sperm maduration, for their sterility. These data suggest SHP-1 plays an important role in prostate epithelial morphogenesis. Copyright © 2014 AEU. Published by Elsevier Espana. All rights reserved.
Nicolucci, P; Schuch, F
2012-06-01
To use the Monte Carlo code PENELOPE to study attenuation and tissue equivalence properties of a-Al2O3:C for OSL dosimetry. Mass attenuation coefficients of α-Al2O3 and α-Al2O3:C with carbon percent weight concentrations from 1% to 150% were simulated with PENELOPE Monte Carlo code and compared to mass attenuation coefficients from soft tissue for photon beams ranging from 50kV to 10MV. Also, the attenuation of primary photon beams of 6MV and 10MV and the generation of secondary electrons by α-Al2O3 :C dosimeters positioned on the entrance surface of a water phantom were studied. A difference of up to 90% was found in the mass attenuation coefficient between the pure \\agr;-A12O3 and the material with 150% weight concentration of dopant at 1.5 keV, corresponding to the K-edge photoelectric absorption of aluminum. However for energies above 80 keV the concentration of carbon does not affect the mass attenuation coefficient and the material presents tissue equivalence for the beams studied. The ratio between the mass attenuation coefficients for \\agr-A12O3:C and for soft tissue are less than unit due to the higher density of the \\agr-A12O3 (2.12 g/cm s ) and its tissue equivalence diminishes to lower concentrations of carbon and for lower energies due to the relation of the radiation interaction effects with atomic number. The larger attenuation of the primary photon beams by the dosimeter was 16% at 250 keV and the maximum increase in secondary electrons fluence to the entrance surface of the phantom was found as 91% at 2MeV. The use of the OSL dosimeters in radiation therapy can be optimized by use of PENELOPE Monte Carlo simulation to provide a study of the attenuation and response characteristics of the material. © 2012 American Association of Physicists in Medicine.
IBA analysis of some precolumbian gilded-copper samples
NASA Astrophysics Data System (ADS)
Andrade, E.; Murillo, G.; Policroniades, R.; Acosta, L.; Zavala, E. P.; Rocha, M. F.; Centeno, S. A.
2005-10-01
The elemental composition and depth profiles obtained by IBA techniques on some gilded-copper fragments from the Moche site of Loma Negra, in the Piura Valley, on the Northern Coast of Perú are presented in this article. A previous radiocarbon dating of a wooden fragment indicated that Loma Negra was occupied around 295 AD. A PIXE analysis using a 2.6 MeV external proton beam, was used to obtain the concentration of trace elements in the samples. RBS analyses using 2.72 MeV 4He+ and 12.0 MeV 12C3+ were used to obtain the Au, Ag, Cu atomic profiles. NRA with a 1.02 MeV deuteron beam was used to measure the oxygen and carbon concentrations through the 16O(d,p) 17O, 16O(d,α) 14N and 12C(d,p0) 13C reactions.
An efficient approach to integrated MeV ion imaging.
Nikbakht, T; Kakuee, O; Solé, V A; Vosuoghi, Y; Lamehi-Rachti, M
2018-03-01
An ionoluminescence (IL) spectral imaging system, besides the common MeV ion imaging facilities such as µ-PIXE and µ-RBS, is implemented at the Van de Graaff laboratory of Tehran. A versatile processing software is required to handle the large amount of data concurrently collected in µ-IL and common MeV ion imaging measurements through the respective methodologies. The open-source freeware PyMca, with image processing and multivariate analysis capabilities, is employed to simultaneously process common MeV ion imaging and µ-IL data. Herein, the program was adapted to support the OM_DAQ listmode data format. The appropriate performance of the µ-IL data acquisition system is confirmed through a case study. Moreover, the capabilities of the software for simultaneous analysis of µ-PIXE and µ-RBS experimental data are presented. Copyright © 2017 Elsevier B.V. All rights reserved.
Coupled channel analysis of overlinepp annihilation into π0π0π0, π0ηη and π0π0η
NASA Astrophysics Data System (ADS)
Amsler, C.; Armstrong, D. S.; Baker, C. A.; Barnett, B. M.; Batty, C. J.; Benayoun, M.; Beuchert, K.; Birien, P.; Blüm, P.; Bossingham, R.; Braune, K.; Brose, J.; Bugg, D. V.; Case, T.; Chung, S. U.; Cooper, A. R.; Cramer, O.; Crowe, K. M.; Degener, T.; Dietz, H. P.; Djaoshvili, N.; Dombroski, S. v.; Doser, M.; Dünnweber, W.; Engelhardt, D.; Englert, M.; Faessler, M. A.; Felix, C.; Giarritta, P.; Hackmann, R.; Haddock, R. P.; Heinsius, F. H.; Herz, M.; Hessey, N. P.; Hidas, P.; Holzhaussen, C.; Illinger, P.; Jamnik, D.; Kalinowsky, H.; Kalteyer, B.; Kämmle, B.; Kiel, T.; Kisiel, J.; Klempt, E.; Koch, H.; Kobel, M.; Kolo, C.; Kunze, M.; Lakata, M.; Landua, R.; Lüdemann, J.; Matthäy, H.; McCrady, R.; Merlo, J. P.; Meyer, C. A.; Montanet, L.; Noble, A.; Ouared, R.; Ould-Saada, F.; Peters, K.; Pinder, C. N.; Pinter, G.; Ravndal, S.; Regenfus, C.; Schäfer, E.; Schmidt, P.; Schütrumpf, M.; Seibert, R.; Spanier, S.; Stöck, H.; Straßburger, C.; Strohbusch, U.; Suffert, M.; Thoma, U.; Tischhäuser, M.; Urner, D.; Völcker, C.; Walter, F.; Walther, D.; Wiedner, U.; Winter, N.; Zoll, J.; Zou, B. S.; Zupančič, Č.; Crystal Barrel Collaboration
1995-02-01
We confirm the existence of the two IG( JPC) = 0 +(0 ++) resonances f0(1370) and f0(1500) reported by us in earlier analyses. The analysis presented here couples the final states π0π0π0, π0π0η and π0ηη of overlinepp annihilation at rest. It is based on a 3 × 3 K-matrix. We find masses and widths of M = (1390±30) MeV, Γ = (380±80) MeV; and M = (1500±10) MeV, Γ = (154 ± 30) MeV, respectively. The product branching ratios for the production and decay into π0π0 and ηη of the f 0(1500) are (1.27 ± 0.33) · 10 -3 and (0.60 ± 0.17) · 10 -3, respectively.
Theoretical detection limit of PIXE analysis using 20 MeV proton beams
NASA Astrophysics Data System (ADS)
Ishii, Keizo; Hitomi, Keitaro
2018-02-01
Particle-induced X-ray emission (PIXE) analysis is usually performed using proton beams with energies in the range 2∼3 MeV because at these energies, the detection limit is low. The detection limit of PIXE analysis depends on the X-ray production cross-section, the continuous background of the PIXE spectrum and the experimental parameters such as the beam currents and the solid angle and detector efficiency of X-ray detector. Though the continuous background increases as the projectile energy increases, the cross-section of the X-ray increases as well. Therefore, the detection limit of high energy proton PIXE is not expected to increase significantly. We calculated the cross sections of continuous X-rays produced in several bremsstrahlung processes and estimated the detection limit of a 20 MeV proton PIXE analysis by modelling the Compton tail of the γ-rays produced in the nuclear reactions, and the escape effect on the secondary electron bremsstrahlung. We found that the Compton tail does not affect the detection limit when a thin X-ray detector is used, but the secondary electron bremsstrahlung escape effect does have an impact. We also confirmed that the detection limit of the PIXE analysis, when used with 4 μm polyethylene backing film and an integrated beam current of 1 μC, is 0.4∼2.0 ppm for proton energies in the range 10∼30 MeV and elements with Z = 16-90. This result demonstrates the usefulness of several 10 MeV cyclotrons for performing PIXE analysis. Cyclotrons with these properties are currently installed in positron emission tomography (PET) centers.
NASA Astrophysics Data System (ADS)
Asratyan, A. E.; Dolgolenko, A. G.; Kubantsev, M. A.
2005-05-01
Three baryon resonances with masses of 1532.2±1.3, 1577.7±1.9, and 1658.6±4.4MeV are observed in invariant mass of the KS0p system formed in neutrino and antineutrino collisions with deuterons and neon nuclei. Observed widths of the 1532-MeV and 1578-MeV resonances are consistent with being entirely due to apparatus smearing, and their intrinsic widths are restricted to Γ<12 and 23 MeV, respectively. For the 1659-MeV resonance, the data suggest a nonvanishing intrinsic width of Γ˜20MeV. Significance levels of the three signals are near 7.1 σ, 5.0 σ, and 4.5 σ, respectively. The Σ hypothesis for either of these three resonances is disfavored by the data on associated Λ hyperons and on formation of the Λ π system. These resonant states are tentatively interpreted as the recently discovered pentaquark baryon Θ(1530) and its spin/isospin partners. The analysis is based on neutrino data collected by past bubble-chamber experiments.
NASA Astrophysics Data System (ADS)
Carasco, C.; Perot, B.; Viesti, G.; Valkovic, V.; Sudac, D.; Bernard, S.; Mariani, A.; Szabo, J.-L.; Sannie, G.; Lunardon, M.; Bottosso, C.; Moretto, S.; Pesente, S.; Peerani, P.; Sequeira, V.; Salvato, M.
2007-11-01
The EURopean Illicit TRAfficking Countermeasures Kit (EURITRACK) inspection system uses 14 MeV neutrons produced by the D(T,n α) reaction to detect explosives in cargo containers. Fast-neutron-induced reactions inside the container produce gamma rays, which are detected in coincidence with the associated alpha particle. The definition of the neutron path and the time-of-flight measurement allow positioning the source of the gamma ray inside the container, while the chemical composition of the target material is correlated with the energy spectrum of the coincident gamma rays. However, in case of dense cargo, neutron moderation and photon attenuation inside the container make difficult the reconstruction of the material composition from the measured gamma-ray energy spectrum. An analytical method has been developed and validated against experimental data, which allows obtaining the chemical carbon-to-oxygen and carbon-to-nitrogen ratios of the inspected items from the gamma-ray energy spectra. The principle of the method is presented along with validation tests.
Lin, Wen-Hsuan; Griffin, Diane E.; Rota, Paul A.; Papania, Mark; Cape, Stephen P.; Bennett, David; Quinn, Brian; Sievers, Robert E.; Shermer, Charles; Powell, Kenneth; Adams, Robert J.; Godin, Steven; Winston, Scott
2011-01-01
Measles remains an important cause of childhood mortality worldwide. Sustained high vaccination coverage is the key to preventing measles deaths. Because measles vaccine is delivered by injection, hurdles to high coverage include the need for trained medical personnel and a cold chain, waste of vaccine in multidose vials and risks associated with needle use and disposal. Respiratory vaccine delivery could lower these barriers and facilitate sustained high coverage. We developed a novel single unit dose, dry powder live-attenuated measles vaccine (MVDP) for respiratory delivery without reconstitution. We tested the immunogenicity and protective efficacy in rhesus macaques of one dose of MVDP delivered either with a mask or directly intranasal with two dry powder inhalers, PuffHaler and BD Solovent. MVDP induced robust measles virus (MeV)-specific humoral and T-cell responses, without adverse effects, which completely protected the macaques from infection with wild-type MeV more than one year later. Respiratory delivery of MVDP was safe and effective and could aid in measles control. PMID:21282608
Lin, Wen-Hsuan; Griffin, Diane E; Rota, Paul A; Papania, Mark; Cape, Stephen P; Bennett, David; Quinn, Brian; Sievers, Robert E; Shermer, Charles; Powell, Kenneth; Adams, Robert J; Godin, Steven; Winston, Scott
2011-02-15
Measles remains an important cause of childhood mortality worldwide. Sustained high vaccination coverage is the key to preventing measles deaths. Because measles vaccine is delivered by injection, hurdles to high coverage include the need for trained medical personnel and a cold chain, waste of vaccine in multidose vials and risks associated with needle use and disposal. Respiratory vaccine delivery could lower these barriers and facilitate sustained high coverage. We developed a novel single unit dose, dry powder live-attenuated measles vaccine (MVDP) for respiratory delivery without reconstitution. We tested the immunogenicity and protective efficacy in rhesus macaques of one dose of MVDP delivered either with a mask or directly intranasal with two dry powder inhalers, PuffHaler and BD Solovent. MVDP induced robust measles virus (MeV)-specific humoral and T-cell responses, without adverse effects, which completely protected the macaques from infection with wild-type MeV more than one year later. Respiratory delivery of MVDP was safe and effective and could aid in measles control.
Experimental evidence of the 6He level at E*=18.3 MeV via the 4He + 3H three-body reaction
NASA Astrophysics Data System (ADS)
Povoroznyk, O. M.; Gorpinich, O. K.; Jachmenjov, O. O.; Mokhnach, H. V.; Ponkratenko, O.; Mandaglio, G.; Curciarello, F.; De Leo, V.; Fazio, G.; Giardina, G.
2012-06-01
Measurements of the t-t and p-t coincidence events in the 3H (α,tt)1H reaction have been obtained at incident energy Eα=67.2 MeV. Various appropriate angular configurations of detectors were chosen in order to observe the population of the 6He* state at around 18 MeV. Its contribution appears at the relative energy of Ett=6.0 MeV as found from an analysis of the bidimensional spectra. We found the formation of the 6He excited state at E*=18.3±0.2 MeV (with a Γ width of 1.1 ± 0.3 MeV) by using the decay into the t+t binary channel, since the threshold energy of the t+t channel is 12.31 MeV. In each analyzed bidimensional energy spectrum of (Et, Et) and (Ep, Et) coincidence events, resonance structures are present due to the formation of both 6He* and 4He* excited states. Our results on the E* and Γ values regarding the 6He* level of about 18 MeV are compared with the results obtained using other reactions. Moreover, we also found new Γ width values of 0.7 ± 0.3 and 0.8 ± 0.4 MeV for the 14.0 ± 0.4 and 16.1 ± 0.4 MeV 6He levels, respectively.
Extensions to the integral line-beam method for gamma-ray skyshine analyses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shultis, J.K.; Faw, R.E.
1995-08-01
A computationally simple method for estimating gamma-ray skyshine dose rates has been developed on the basis of the line-beam response function. Both Monte Carlo and pointkernel calculations that account for both annihilation and bremsstrahlung were used in the generation of line beam response functions (LBRF) for gamma-ray energies between 10 and 100 MeV. The LBRF is approximated by a three-parameter formula. By combining results with those obtained in an earlier study for gamma energies below 10 MeV, LBRF values are readily and accurately evaluated for source energies between 0.02 and 100 MeV, for source-to-detector distances between 1 and 3000 m,more » and beam angles as great as 180 degrees. Tables of the parameters for the approximate LBRF are presented. The new response functions are then applied to three simple skyshine geometries, an open silo geometry, an infinite wall, and a rectangular four-wall building. Results are compared to those of previous calculations and to benchmark measurements. A new approach is introduced to account for overhead shielding of the skyshine source and compared to the simplistic exponential-attenuation method used in earlier studies. The effect of the air-ground interface, usually neglected in gamma skyshine studies, is also examined and an empirical correction factor is introduced. Finally, a revised code based on the improved LBRF approximations and the treatment of the overhead shielding is presented, and results shown for several benchmark problems.« less
Fei-Fei, Diao; Yong-Feng, Zhao; Jian-Li, Wang; Xue-Hua, Wei; Kai, Cui; Chuan-Yi, Liu; Shou-Yu, Guo; Jiang, Shijin; Zhi-Jing, Xie
2017-06-01
Six feline panleukopenia viruses (FPV) were detected in the intestinal samples from the 176 mink collected in China during 2015 to 2016, named MEV-SD1, MEV-SD2, MEV-SD3, MEV-SD4, MEV-SD5 and MEV-SD6. The VP2 genes of the isolates shared 98.9%-100% identity with the reference sequences. The substitution of residue V300A in VP2 protein differentiates the isolates from the reference MEVs, and A300 is a characteristic of FPV. Furthermore, phylogenetic analysis of VP2 genes indicated that the six isolates were clustered into the same branch of all the reference FPVs. The NS1 genes of the isolates shared 98.2%-100% identity with the reference sequences. The NS1 genes of the six isolates and the three reference FPVs formed one unique evolutionary branch. To clarify the pathogenicity of the isolates, animal experiments were performed on healthy mink, using MEV-SD1. As a result, the morbidity of the inoculated animals was 100% and the mortality was as high as 38.9%. It was implied that the FPV infection caused a high morbidity and mortality in mink and the inoculation dose had an effect on pathogenicity of MEV-SD1 in mink. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Peng, Bo-dong; Hei, Dong-wei; Song, Yan; Liu, Jun; Zhao, Jun
2018-04-01
To measure the temporal width and the intensity evolution versus time of a MeV gamma pulse generated by a Compton Scatter Source, a time-space conversion method is proposed. This design is based on the consideration that the temporal length of the MeV pulse is proportional to the spatial length of the pulse in a certain semiconductor. The spatial length and the intensity evolution versus time of the MeV pulse can be obtained by recording the region of the refractive index change that is induced by the MeV pulse. The simulation suggests that the equivalent temporal spread of a mono-energy MeV δ pulse in a bulk semiconductor is on the order of picoseconds and does not vary significantly with photon energy and material type. According to our analysis, the excess carrier generation time, excess carrier diffusion and recombination do not significantly influence the temporal resolution of this method. The temporal response of the refractive index change to a MeV pulse is also fast enough to meet the measurement requirements. The signal generation process for measuring a 10-ps MeV pulse with a 200-fs probe beam is analyzed, revealing that the transverse size of the MeV pulse does not influence the temporal resolution of this method.
Measurement and analysis of gamma-rays emitted from spent nuclear fuel above 3 MeV.
Rodriguez, Douglas C; Anderson, Elaina; Anderson, Kevin K; Campbell, Luke W; Fast, James E; Jarman, Kenneth; Kulisek, Jonathan; Orton, Christopher R; Runkle, Robert C; Stave, Sean
2013-12-01
The gamma-ray spectrum of spent nuclear fuel in the 3-6 MeV energy range is important for active interrogation since gamma rays emitted from nuclear decay are not expected to interfere with measurements in this energy region. There is, unfortunately, a dearth of empirical measurements from spent nuclear fuel in this region. This work is an initial attempt to partially fill this gap by presenting an analysis of gamma-ray spectra collected from a set of spent nuclear fuel sources using a high-purity germanium detector array. This multi-crystal array possesses a large collection volume, providing high energy resolution up to 16 MeV. The results of these measurements establish the continuum count-rate in the energy region between 3 and 6 MeV. Also assessed is the potential for peaks from passive emissions to interfere with peak measurements resulting from active interrogation delayed emissions. As one of the first documented empirical measurements of passive emissions from spent fuel for energies above 3 MeV, this work provides a foundation for active interrogation model validation and detector development. © 2013 Elsevier Ltd. All rights reserved.
Determination of neutron spectra within the energy of 1 keV to 1 MeV by means of reactor dosimetry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sergeyeva, Victoria; Destouches, Christophe; Lyoussi, Abdallah
2015-07-01
The standard procedure for neutron reactor dosimetry is based on neutron irradiation of a target and its post-irradiation analysis by Gamma and/or X-ray spectrometry. Nowadays, the neutron spectra can be easily characterized for thermal and fast energies (respectively 0.025 eV and >1 MeV). In this work we propose a new target and an innovating post-irradiation technique of analysis in order to detect the neutron spectra within the energy of 1 keV to 1 MeV. This article will present the calculations performed for the selection of a suitable nuclear reaction and isotope, the results predicted by simulations, the irradiation campaign thatmore » is proposed and the post-irradiation technique of analysis. (authors)« less
High-Lying 6Li Levels at Excitation Energy of around 21 MeV
NASA Astrophysics Data System (ADS)
Povoroznyk, Orest; Gorpinich, Olga K.; Jachmenjov, Olexiy O.; Mokhnach, Hanna V.; Ponkratenko, Oleg; Mandaglio, Giuseppe; Curciarello, Francesca; De Leo, Veronica; Fazio, Giovanni; Giardina, Giorgio
2011-09-01
The 3 cluster structure in 6Li was investigated by the 3H(α,3H 3He)n kinematically complete experiment at the incident energy Eα = 67.2 MeV. We have observed two resonances at Ex* = 21.30 and 21.90 MeV, which are consistent with the results of 3He(3H, γ)6Li analysis in the Ajzenberg-Selove compilation. Our data are compared with the previous experimental data and the RGM and CSRGM calculations.
A new model for the calculation and prediction of solar proton fluences
NASA Technical Reports Server (NTRS)
Feynman, Joan; Gabriel, Stephen B.
1990-01-01
A new predictive engineering model for the energy greater than 10 MeV and greater than 30 MeV solar proton environment at earth is reviewed. The data used are from observations made from 1956 through 1985. In this data set, the distinction between 'ordinary events' and 'anomalously large events' that was required in earlier models disappeared. This permitted the use of statistical analysis methods developed for ordinary events on the entire data set. The greater than 10-MeV fluences with the new model are about twice those expected on the basis of earlier models. At energies greater than 30 MeV, the old and new models agree.
Check for chirality in {sup 102}Rh
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tonev, D.; Goutev, N.; Yavahchova, M. S.
2012-10-20
Excited states in {sup 102}Rh, populated by the fusion-evaporation reaction {sup 94}Zr({sup 11}B,3n){sup 102}Rh at a beam energy of 36 MeV, were studied using the INGA spectrometer at IUAC, New Delhi. The angular correlations and the electromagnetic character of some of the gamma-ray transitions observed were investigated in details. A new chiral candidate sister band was found in the level-scheme of {sup 102}Rh. Lifetimes of exited states in {sup 102}Rh were measured by means of the Doppler-shift attenuation technique. The experimental results do not support the presence of static chirality in {sup 102}Rh.
WebMeV | Informatics Technology for Cancer Research (ITCR)
Web MeV (Multiple-experiment Viewer) is a web/cloud-based tool for genomic data analysis. Web MeV is being built to meet the challenge of exploring large public genomic data set with intuitive graphical interface providing access to state-of-the-art analytical tools.
Borexino's search for low-energy neutrino and antineutrino signals correlated with gamma-ray bursts
NASA Astrophysics Data System (ADS)
Agostini, M.; Altenmüller, K.; Appel, S.; Atroshchenko, V.; Bellini, G.; Benziger, J.; Bick, D.; Bonfini, G.; Bravo, D.; Caccianiga, B.; Calaprice, F.; Caminata, A.; Carlini, M.; Cavalcante, P.; Chepurnov, A.; Choi, K.; D'Angelo, D.; Davini, S.; de Kerret, H.; Derbin, A.; Di Noto, L.; Drachnev, I.; Etenko, A.; Fomenko, K.; Franco, D.; Gabriele, F.; Galbiati, C.; Ghiano, C.; Giammarchi, M.; Goeger-Neff, M.; Goretti, A.; Gromov, M.; Hagner, C.; Hungerford, E.; Ianni, Aldo; Ianni, Andrea; Jany, A.; Jedrzejczak, K.; Jeschke, D.; Kobychev, V.; Korablev, D.; Korga, G.; Kryn, D.; Laubenstein, M.; Lehnert, B.; Litvinovich, E.; Lombardi, F.; Lombardi, P.; Ludhova, L.; Lukyanchenko, G.; Machulin, I.; Manecki, S.; Maneschg, W.; Manuzio, G.; Marcocci, S.; Meroni, E.; Meyer, M.; Miramonti, L.; Misiaszek, M.; Montuschi, M.; Mosteiro, P.; Muratova, V.; Neumair, B.; Oberauer, L.; Obolensky, M.; Ortica, F.; Pallavicini, M.; Papp, L.; Pocar, A.; Ranucci, G.; Razeto, A.; Re, A.; Romani, A.; Roncin, R.; Rossi, N.; Schönert, S.; Semenov, D.; Skorokhvatov, M.; Smirnov, O.; Sotnikov, A.; Sukhotin, S.; Suvorov, Y.; Tartaglia, R.; Testera, G.; Thurn, J.; Toropova, M.; Unzhakov, E.; Vishneva, A.; Vogelaar, R. B.; von Feilitzsch, F.; Wang, H.; Weinz, S.; Winter, J.; Wojcik, M.; Wurm, M.; Yokley, Z.; Zaimidoroga, O.; Zavatarelli, S.; Zuber, K.; Zuzel, G.; Borexino Collaboration
2017-01-01
A search for neutrino and antineutrino events correlated with 2350 gamma-ray bursts (GRBs) is performed with Borexino data collected between December 2007 and November 2015. No statistically significant excess over background is observed. We look for electron antineutrinos (νbare) that inverse beta decay on protons with energies from 1.8 MeV to 15 MeV and set the best limit on the neutrino fluence from GRBs below 8 MeV. The signals from neutrinos and antineutrinos from GRBs that scatter on electrons are also searched for, a detection channel made possible by the particularly radio-pure scintillator of Borexino. We obtain currently the best limits on the neutrino fluence of all flavors and species below 7 MeV. Finally, time correlations between GRBs and bursts of events are investigated. Our analysis combines two semi-independent data acquisition systems for the first time: the primary Borexino readout optimized for solar neutrino physics up to a few MeV, and a fast waveform digitizer system tuned for events above 1 MeV.
Proton Irradiation-Induced Metal Voids in Gallium Nitride High Electron Mobility Transistors
2015-09-01
13. ABSTRACT (maximum 200 words) Gallium nitride/aluminum gallium nitride high electron mobility transistors with nickel/ gold (Ni/Au) and...platinum/ gold (Pt/Au) gating are irradiated with 2 MeV protons. Destructive physical analysis revealed material voids underneath the gate finger of the...nickel/ gold (Ni/Au) and platinum/ gold (Pt/Au) gating are irradiated with 2 MeV protons. Destructive physical analysis revealed material voids underneath
Calibration of the JET neutron activation system for DT operation
NASA Astrophysics Data System (ADS)
Bertalot, L.; Roquemore, A. L.; Loughlin, M.; Esposito, B.
1999-01-01
The neutron activation system at JET is a pneumatic transfer system capable of positioning activation samples close to the plasma. Its primary purpose is to provide a calibration for the time-dependent neutron yield monitors (fission chambers and solid state detectors). Various activation reactions with different high energy thresholds were used including 56Fe(n,p) 56Mn, 27Al(n,α) 24Na, 93Nb(n,2n) 92mNb, and 28Si(n,p) 28Al reactions. The silicon reaction, with its short half life (2.25 min), provides a prompt determination of the 14 MeV DT yield. The neutron induced γ-ray activity of the Si samples was measured using three sodium iodide scintillators, while two high purity germanium detectors were used for other foils. It was necessary to use a range of sample masses and different counting geometries in order to cover the wide range of neutron yields (1015-1019 neutrons) while avoiding excessive count rates in the detectors. The absolute full energy peak efficiency calibration of the detectors was measured taking into account the source-detector geometry, the self-attenuation of the samples and cross-talk effects. An error analysis of the neutron yield measurement was performed including uncertainties in efficiency calibration, neutron transport calculations, cross sections, and counting statistics. Cross calibrations between the different irradiation ends were carried out in DD and DT (with 1% and 10% tritium content) discharges. The effect of the plasma vertical displacement was also experimentally studied. An agreement within 10% was found between the 14 MeV neutron yields measured from Si, Fe, Al, Nb samples in DT discharges.
The total kinetic energy release in the fast neutron-induced fission of 232Th
DOE Office of Scientific and Technical Information (OSTI.GOV)
King, Jonathan; Yanez, Ricardo; Loveland, Walter
Here, the post-emission total kinetic energy release (TKE) in the neutron-induced fission of 232Th was measured (using white spectrum neutrons from LANSCE) for neutron energies from E n=3 to 91MeV. In this energy range the average post-neutron total kinetic energy release decreases from 162.3±0.3 at E n=3 MeV to 154.9±0.3 MeV at E n=91 MeV. Analysis of the fission mass distributions indicates that the decrease in TKE with increasing neutron energy is a combination of increasing yields of symmetric fission (which has a lower associated TKE) and a decrease in the TKE release in asymmetric fission.
The total kinetic energy release in the fast neutron-induced fission of 232Th
King, Jonathan; Yanez, Ricardo; Loveland, Walter; ...
2017-12-15
Here, the post-emission total kinetic energy release (TKE) in the neutron-induced fission of 232Th was measured (using white spectrum neutrons from LANSCE) for neutron energies from E n=3 to 91MeV. In this energy range the average post-neutron total kinetic energy release decreases from 162.3±0.3 at E n=3 MeV to 154.9±0.3 MeV at E n=91 MeV. Analysis of the fission mass distributions indicates that the decrease in TKE with increasing neutron energy is a combination of increasing yields of symmetric fission (which has a lower associated TKE) and a decrease in the TKE release in asymmetric fission.
A new gamma ray imaging diagnostic for runaway electron studies at DIII-D
NASA Astrophysics Data System (ADS)
Cooper, C. M.; Pace, D. C.; Eidietis, N. W.; Paz-Soldan, C.; Commaux, N.; Shiraki, D.; Hollmann, E. M.; Moyer, R. A.; Risov, V.
2015-11-01
A new Gamma Ray Imager (GRI) is developed to probe the electron distribution function with 2D spatial resolution during runaway electron (RE) experiments at DIII-D. The diagnostic is sensitive to 0.5 - 50 MeV gamma rays, allowing characterization of the RE distribution function evolution during RE dissipation from pellet injection. The GRI consists of a lead ``pinhole camera'' mounted on the midplane with 11x11 counter-current tangential chords 20 cm wide that span the vessel. Up to 30 bismuth germanate (BGO) scintillation detectors capture RE Bremsstrahlung radiation. Detectors operate in current saturation mode at 10 MHz, or the flux is attenuated for Pulse Height Analysis (PHA) capable of discriminating up to ~10k pulses per second. Digital signal processing routines combining shaping filters are performed during PHA to reject noise and record gamma ray energy. The GRI setup and PHA algorithms will be described and initial data from experiments will be presented. Work supported by the US DOE under DE-AC05-00OR22725, DE-FG02-07ER54917 & DE-FC02-04ER54698.
NASA Astrophysics Data System (ADS)
Devito, R. P.; Khoa, Dao T.; Austin, Sam M.; Berg, U. E. P.; Loc, Bui Minh
2012-02-01
Background: Analysis of data involving nuclei far from stability often requires the optical potential (OP) for neutron scattering. Because neutron data are seldom available, whereas proton scattering data are more abundant, it is useful to have estimates of the difference of the neutron and proton optical potentials. This information is contained in the isospin dependence of the nucleon OP. Here we attempt to provide it for the nucleon-208Pb system.Purpose: The goal of this paper is to obtain accurate n+208Pb scattering data and use it, together with existing p+208Pb and 208Pb(p,n)208BiIAS* data, to obtain an accurate estimate of the isospin dependence of the nucleon OP at energies in the 30-60-MeV range.Method: Cross sections for n+208Pb scattering were measured at 30.4 and 40.0 MeV, with a typical relative (normalization) accuracy of 2-4% (3%). An angular range of 15∘ to 130∘ was covered using the beam-swinger time-of-flight system at Michigan State University. These data were analyzed by a consistent optical-model study of the neutron data and of elastic p+208Pb scattering at 45 and 54 MeV. These results were combined with a coupled-channel analysis of the 208Pb(p,n) reaction at 45 MeV, exciting the 0+ isobaric analog state (IAS) in 208Bi.Results: The new data and analysis give an accurate estimate of the isospin impurity of the nucleon-208Pb OP at 30.4 MeV caused by the Coulomb correction to the proton OP. The corrections to the real proton OP given by the CH89 global systematics were found to be only a few percent, whereas for the imaginary potential it was greater than 20% at the nuclear surface. On the basis of the analysis of the measured elastic n+208Pb data at 40 MeV, a Coulomb correction of similar strength and shape was also predicted for the p+208Pb OP at energies around 54 MeV.Conclusions: Accurate neutron scattering data can be used in combination with proton scattering data and (p,n) charge exchange data leading to the IAS to obtain reliable estimates of the isospin impurity of the nucleon OP.
NASA Astrophysics Data System (ADS)
Hill, M. E.; Mitchell, D. G.; McNutt, R. L., Jr.; Cooper, S.; Crew, A. B.; Dupont, A.; Hayes, J.; Hoffer, E.; Nelson, K.; Parker, C.; Schlemm, C., II; Seifert, H.; Stokes, M.; Angold, N. G.; McComas, D. J.; Weidner, S.; Wiedenbeck, M. E.
2016-12-01
The Solar Probe Plus (SPP) Mission's Integrated Science Investigation of the Sun (ISIS) is a suite of two energetic particle instruments, EPI-Lo and EPI-Hi, covering lower ( 10 keV-100 MeV) and higher ( 1-100 MeV/nuc) energies, respectively. The ISIS team will investigate the origins, acceleration, and transport of energetic particles in the corona and inner heliosphere during the planned 7-year, 24-orbit mission, with a perihelion initially of 0.16 AU (36 Solar radii; RS), the three final orbits reaching 0.044 AU (9.9 RS). EPI-Lo has a novel approach to obtaining large angular coverage, well-suited to 3-axis stabilized spacecraft such as SPP, by densely sampling its 2π steradian field of view with 80 apertures organized in eight matching, 10-aperture wedges. Each wedge relies primarily on time-of-flight (TOF) mass spectrometer techniques, employing thin secondary-electron-emitting foils, microchannel plates, and solid state detectors (SSDs), to measure ions from 50 keV - 15 MeV and electrons from 50-500 keV. Signal attenuation, absorbers, TOF-only measurements, and SSD-only techniques are used to extend this energy range higher and lower. In 2015 and 2016 we made measurements with engineering units and flight-spare EPI-Lo wedges at accelerators and with radioactive sources; in addition to presenting the instrument design, we will report the results from these tests to characterize the instrument's measurement performance.
Determining photon energy absorption parameters for different soil samples
Kucuk, Nil; Tumsavas, Zeynal; Cakir, Merve
2013-01-01
The mass attenuation coefficients (μs) for five different soil samples were measured at 661.6, 1173.2 and 1332.5 keV photon energies. The soil samples were separately irradiated with 137Cs and 60Co (370 kBq) radioactive point gamma sources. The measurements were made by performing transmission experiments with a 2″ × 2″ NaI(Tl) scintillation detector, which had an energy resolution of 7% at 0.662 MeV for the gamma-rays from the decay of 137Cs. The effective atomic numbers (Zeff) and the effective electron densities (Neff) were determined experimentally and theoretically using the obtained μs values for the soil samples. Furthermore, the Zeff and Neff values of the soil samples were computed for the total photon interaction cross-sections using theoretical data over a wide energy region ranging from 1 keV to 15 MeV. The experimental values of the soils were found to be in good agreement with the theoretical values. Sandy loam and sandy clay loam soils demonstrated poor photon energy absorption characteristics. However, clay loam and clay soils had good photon energy absorption characteristics. PMID:23179375
Reduced Noise UV Enhancement of Etch Rates for Nuclear Tracks in CR-39
NASA Astrophysics Data System (ADS)
Sheets, Rebecca; Clarkson, David; Ume, Rubab; Regan, Sean; Sangster, Craig; Padalino, Stephen; McLean, James
2016-10-01
The use of CR-39 plastic as a Solid State Nuclear Track Detector is an effective technique for obtaining data in high-energy particle experiments including inertial confinement fusion. To reveal particle tracks after irradiation, CR-39 is chemically etched in NaOH at 80°C for 6 hours, producing micron-scale signal pits at the nuclear track sites. Using CR-39 irradiated with 5.4 MeV alpha particles and 1.0 MeV protons, we show that exposing the CR-39 to high intensity UV light before etching, with wavelengths between 240 nm and 350 nm, speeds the etch process. Elevated temperatures during UV exposure amplifies this effect, with etch rates up to 50% greater than unprocessed conditions. CR-39 pieces exposed to UV light and heat can also exhibit heightened levels of etch-induced noise (surface features not caused by nuclear particles). By illuminating the CR-39 from the side opposite to the tracks, a similar level of etch enhancement was obtained with little to no noise. The effective wavelength range is reduced, due to strong attenuation of shorter wavelengths. Funded in part by a LLE contract through the DOE.
Structure of positive parity bands and observation of magnetic rotation in 108Ag
NASA Astrophysics Data System (ADS)
Sethi, Jasmine; Palit, R.
2015-10-01
The interplay of nuclear forces among the neutron particles (holes) and proton holes (particles) in the odd-odd nuclei gives rise to a variety of shapes and hence novel modes of excitations. The odd-odd nuclei in the A ~ 110 region have proton holes in the g9/2 orbital and the neutron particles in the h11/2 orbitals. A systematic study of shears mechanism in A ~ 110 region indicates the presence of magnetic rotation (MR) phenomenon in Ag and In isotopes. Therefore, the structure of doubly odd 108Ag nucleus was probed in two different reactions, i.e, 100Mo(11B, 4n)108Ag at 39 MeV and 94Zr(18O, p3n)108Ag at 72 MeV beam energies. The emitted γ-rays were detected using the Indian National Gamma Array (INGA) at TIFR, Mumbai. A significant number of new transitions and energy levels were identified. Lifetime measurements, using the Doppler shift attenuation method, have been carried out for a positive parity dipole band. Tilted Axis Cranking (TAC) calculations have been performed for two positive parity dipole bands.
NASA Astrophysics Data System (ADS)
Sayyed, M. I.; Çelikbilek Ersundu, M.; Ersundu, A. E.; Lakshminarayana, G.; Kostka, P.
2018-03-01
In this work, glasses in the MeO-PbCl2-TeO2 (MeO = Bi2O3, MoO3, Sb2O3, WO3, ZnO) system, which show a great potential for optoelectronic applications, were used to evaluate their resistance under high energy ionizing radiations. The basic shielding quantities for determining the penetration of radiation in glass, such as mass attenuation coefficient (μ/ρ), half value layer (HVL), mean free path (MFP) and exposure buildup factor (EBF) values were investigated within the energy range 0.015 MeV ‒ 15 MeV using XCOM program and variation of shielding parameters were compared with different glass systems and ordinary concrete. From the derived results, it was determined that MeO-PbCl2-TeO2 (MeO = Bi2O3, MoO3, Sb2O3, WO3, ZnO) glasses show great potentiality to be used under high energy radiations. Among the studied glass compositions, Bi2O3 and WO3 containing glasses were found to possess superior gamma-ray shielding effectiveness.
SU-F-P-49: Comparison of Mapcheck 2 Commission for Photon and Electron Beams
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lu, J; Yang, C; Morris, B
2016-06-15
Purpose: We will investigate the performance variation of the MapCheck2 detector array with different array calibration and dose calibration pairs from different radiation therapy machine. Methods: A MapCheck2 detector array was calibrated on 3 Elekta accelerators with different energy of photon (6 MV, 10 MV, 15 MV and 18 MV) and electron (6 MeV, 9 MeV, 12 MeV, 15 MeV, 18 MeV and 20 MeV) beams. Dose calibration was conducted by referring a water phantom measurement following TG-51 protocol and commission data for each accelerator. A 10 cm × 10 cm beam was measured. This measured map was morphed bymore » applying different calibration pairs. Then the difference was quantified by comparing the doses and similarity using gamma analysis of criteria (0.5 %, 0 mm). Profile variation was evaluated on a same dataset with different calibration pairs. The passing rate of an IMRT QA planar dose was calculated by using 3 mm and 3% criteria and compared with respect to each calibration pairs. Results: In this study, a dose variation up to 0.67% for matched photons and 1.0% for electron beams is observed. Differences of flatness and symmetry can be as high as 1% and 0.7% respectively. Gamma analysis shows a passing rate ranging from 34% to 85% for the standard 10 × 10 cm field. Conclusion: Our work demonstrated that a customized array calibration and dose calibration for each machine is preferred to fulfill a high standard patient QA task.« less
TANGRA - an experimental setup for basic and applied nuclear research by means of 14.1 MeV neutrons
NASA Astrophysics Data System (ADS)
Ruskov, Ivan; Kopatch, Yury; Bystritsky, Vyacheslav; Skoy, Vadim; Shvetsov, Valery; Hambsch, Franz-Josef; Oberstedt, Stephan; Noy, Roberto Capote; Grozdanov, Dimitar; Zontikov, Artem; Rogov, Yury; Zamyatin, Nikolay; Sapozhnikov, Mikhail; Slepnev, Vyacheslav; Bogolyubov, Evgeny; Sadovsky, Andrey; Barmakov, Yury; Ryzhkov, Valentin; Yurkov, Dimitry; Valković, Vladivoj; Obhođaš, Jasmina; Aliyev, Fuad
2017-09-01
For investigation of the basic characteristics of 14.1 MeV neutron induced nuclear reactions on a number of important isotopes for nuclear science and engineering, a new experimental setup TANGRA has been constructed at the Frank Laboratory of Neutron Physics of the Joint Institute for Nuclear Research in Dubna. For testing its performance, the angular distribution of γ-rays (and neutrons) from the inelastic scattering of 14.1 MeV neutrons on high-purity carbon was measured and the angular anisotropy of γ-rays from the reaction 12C(n, n'γ)12C was determined. This reaction is important from fundamental (differential cross-sections) and practical (non-destructive elemental analysis of materials containing carbon) point of view. The preliminary results for the anisotropy of the γ-ray emission from the inelastic scattering of 14.1- MeV neutrons on carbon are compared with already published literature data. A detailed data analysis for determining the correlations between inelastic scattered neutron and γ-ray emission will be published elsewhere.
Effect of compound nuclear reaction mechanism in 12C(6Li,d) reaction at sub-Coulomb energy
NASA Astrophysics Data System (ADS)
Mondal, Ashok; Adhikari, S.; Basu, C.
2017-09-01
The angular distribution of the 12C(6Li,d) reaction populating the 6.92 and 7.12 MeV states of 16O at sub-Coulomb energy (Ecm=3 MeV) are analysed in the framework of the Distorted Wave Born Approximation (DWBA). Recent results on excitation function measurements and backward angle angular distributions derive ANC for both the states on the basis of an alpha transfer mechanism. In the present work, we show that considering both forward and backward angle data in the analysis, the 7.12 MeV state at sub-Coulomb energy is populated from Compound nuclear process rather than transfer process. The 6.92 MeV state is however produced from direct reaction mechanism.
Shielding small-field high-energy electron beams in cancer treatment
NASA Astrophysics Data System (ADS)
Farahani, M.; Eichmiller, F. C.; McLaughlin, W. L.
1994-04-01
The purpose of this study was to find an effective material that can be prepared quickly and easily prior to small-field electron-beam treatments so that lesions of the head and neck can be treated with minimal irradiation of the surrounding healthy tissue. Conventional preparation of custom anatomical prosthetic radiation shields, which are usually metal alloy masks, has been time-consuming and uncomfortable for the patients. New materials, made from light-body Reprosil TM (L. L. Caulk) filled with fine metal powder consisting of 70% Ag-30% Cu alloy, can be made by blending 90% (w/w) metal powder with 10% polysiloxane base and adding the polymerization catalyst separately. These combinations were mixed to form comfortably fitted shielding composites of different thicknesses. The electron-beam attenuation properties of slabs of this material were studied by irradiating calibrated radiochromic film (GafChromic TM) dosimeters behind different thicknesses of composite samples with small-field 13-, 15- and 18-MeV electron beams from a therapeutic linear accelerator. The results showed that this material can suitably attenuate high-energy electron beams when used in reasonable thicknesses.
Midgley, S M
2004-01-21
A novel parameterization of x-ray interaction cross-sections is developed, and employed to describe the x-ray linear attenuation coefficient and mass energy absorption coefficient for both elements and mixtures. The new parameterization scheme addresses the Z-dependence of elemental cross-sections (per electron) using a simple function of atomic number, Z. This obviates the need for a complicated mathematical formalism. Energy dependent coefficients describe the Z-direction curvature of the cross-sections. The composition dependent quantities are the electron density and statistical moments describing the elemental distribution. We show that it is possible to describe elemental cross-sections for the entire periodic table and at energies above the K-edge (from 6 keV to 125 MeV), with an accuracy of better than 2% using a parameterization containing not more than five coefficients. For the biologically important elements 1 < or = Z < or = 20, and the energy range 30-150 keV, the parameterization utilizes four coefficients. At higher energies, the parameterization uses fewer coefficients with only two coefficients needed at megavoltage energies.
A large area detector for neutrons between 2 and 100 MeV
NASA Technical Reports Server (NTRS)
Grannan, R. T.; Koga, R.; Millard, W. A.; Preszler, A. M.; Simnett, G. M.; White, R. S.
1972-01-01
A neutron detector sensitive from 2 to 100 MeV is described. The detector is designed for high altitude balloon flight to measure the flux, energy and direction of albedo neutrons from the earth and to search for solar neutrons. A neutron scatter from a proton is required in each of two liquid scintillator tanks spaced 1 meter apart. The energy of the recoil proton in the first tank is obtained from pulse height analysis of the scintillator output. The energy of the recoil neutron is obtained from its time of flight between the tanks. The detector has been calibrated with 15.3 MeV neutrons and mu mesons. The minimum detectable flux is 10(-4) neutron/sq cm/sec at a counting rate of one per minute; the energy resolution is 12% at 15 MeV and 30% at 100 MeV. The angle between the incoming neutron and the recoil neutron is measured to + or - 10 deg.
Characteristics of proton beams and secondary neutrons arising from two different beam nozzles
NASA Astrophysics Data System (ADS)
Choi, Yeon-Gyeong; Kim, Yu-Seok
2015-10-01
A tandem or a Van de Graaff accelerator with an energy of 3 MeV is typically used for Proton Induced X-ray Emission (PIXE) analysis. In this study, the beam line design used in the PIXE analysis, instead of the typical low-energy accelerator, was used to increase the production of isotopes from a 13-MeV cyclotron. For the PIXE analysis, the proton beam should be focused at the target through a nozzle after degrading the proton beams energy from 13 MeV to 3 MeV by using an energy degrader. Previous studies have been conducted to determine the most appropriate material for and the thickness of the energy degrader. From the energy distribution of the degraded proton beam and the neutron occurrence rate at the degrader, an aluminum nozzle of X thickness was determined to be the most appropriate nozzle construction. Neutrons are created by the collision of 3-MeV protons in the nozzle after passage through the energy degrader. In addition, a proton beam of sufficient intensity is required for a non-destructive PIXE analysis. Therefore, if nozzle design is to be optimized, the number of neutrons that arise from the collision of protons inside the nozzle, as well as the track direction of the generated secondary neutrons, must be considered, with the primary aim of ensuring that a sufficient number of protons pass through the nozzle as a direct beam. A number of laboratories are currently conducting research related to the design of nozzles used in accelerator fields, mostly medical fields. This paper presents a comparative analysis of two typical nozzle shapes in order to minimize the loss of protons and the generation of secondary neutrons. The neutron occurrence rate and the number of protons that pass through the nozzle were analyzed by using a Particle and Heavy Ion Transport code System (PHITS) program in order to identify the nozzle that generated the strongest proton beam.
Constraints on the bulk Lorentz factor of gamma-ray bursts with the detection rate by Fermi LAT
NASA Astrophysics Data System (ADS)
Chen, Ye; Liu, Ruo-Yu; Wang, Xiang-Yu
2018-05-01
The bulk Lorentz factor(Γ) of the outflow is an essential parameter to understanding the physics of gamma-ray burst (GRB). Informations about the Lorentz factors of some individual GRBs have been obtained from the spectral features of the high-energy gamma-ray emissions (>100 MeV), assuming that the spectral breaks or cutoffs are due to the pair-production attenuation (i.e., γγ → e+e-). In this paper, we attempt to interpret the dependence of the LAT detection rate of GRBs on the number of high-energy gamma-rays, taking into account the attenuation effect. We first simulate a long-GRB sample with Monte Carlo method using the luminosity function, rate distribution with redshift and properties of the GRB spectrum. To characterize the distribution of the Lorentz factors, we assume that the Lorentz factors follow the relation Γ =Γ _0E_iso,52k, where Eiso, 52 is the isotropic photon energy in unit of 1052erg. After taking into account the attenuation effect related with the above Lorentz factor distribution, we are able to reproduce the LAT-detected rate of GRBs as the function of the number of gamma-rays for suitable choice of the values of Γ0 and k. The result suggests that the distribution of the bulk Lorentz factor for the majority of GRBs is in the range of 50 - 250.
Constraints onthe bulk Lorentz factor of gamma-ray burstswith the detection rate by Fermi LAT
NASA Astrophysics Data System (ADS)
Chen, Ye; Liu, Ruo-Yu; Wang, Xiang-Yu
2018-07-01
The bulk Lorentz factor (Γ) of the outflow is an essential parameter for understanding the physics of gamma-ray burst (GRB). Informations about the Lorentz factors of some individual GRBs have been obtained from the spectral features of the high-energy gamma-ray emissions (>100 MeV), assuming that the spectral breaks or cutoffs are due to the pair-production attenuation (i.e. γγ → e+e-). In this paper, we attempt to interpret the dependence of the Large Area Telescope (LAT) detection rate of GRBs on the number of high-energy gamma-rays, taking into account the attenuation effect. We first simulate a long-GRB sample with Monte Carlo method using the luminosity function, rate distribution with redshift, and properties of the GRB spectrum. To characterize the distribution of the Lorentz factors, we assume that the Lorentz factors follow the relation Γ =Γ _0E_{iso, 52}k, where Eiso,52 is the isotropic photon energy in unit of 1052 erg. After taking into account the attenuation effect related with the above Lorentz factor distribution, we are able to reproduce the LAT-detected rate of GRBs as the function of the number of gamma-rays for suitable choice of the values of Γ0 and k. The result suggests that the distribution of the bulk Lorentz factor for the majority of GRBs is in the range of 50-250.
Evidence of nontermination of collective rotation near the maximum angular momentum in Rb75
NASA Astrophysics Data System (ADS)
Davies, P. J.; Afanasjev, A. V.; Wadsworth, R.; Andreoiu, C.; Austin, R. A. E.; Carpenter, M. P.; Dashdorj, D.; Finlay, P.; Freeman, S. J.; Garrett, P. E.; Görgen, A.; Greene, J.; Grinyer, G. F.; Hyland, B.; Jenkins, D. G.; Johnston-Theasby, F. L.; Joshi, P.; Macchiavelli, A. O.; Moore, F.; Mukherjee, G.; Phillips, A. A.; Reviol, W.; Sarantites, D.; Schumaker, M. A.; Seweryniak, D.; Smith, M. B.; Svensson, C. E.; Valiente-Dobon, J. J.; Ward, D.
2010-12-01
Two of the four known rotational bands in Rb75 were studied via the Ca40(Ca40,αp)Rb75 reaction at a beam energy of 165 MeV. Transitions were observed up to the maximum spin Imax of the assigned configuration in one case and one-transition short of Imax in the other. Lifetimes were determined using the residual Doppler shift attenuation method. The deduced transition quadrupole moments show a small decrease with increasing spin, but remain large at the highest spins. The results obtained are in good agreement with cranked Nilsson-Strutinsky calculations, which indicate that these rotational bands do not terminate, but remain collective at Imax.
Radiation effects on ALICE V0 detector components
NASA Astrophysics Data System (ADS)
Cheynis, B.; Ducroux, L.; Grossiord, J.-Y.; Guichard, A.; Pillot, P.; Rapp, B.; Tieulent, R.; Tromeur, W.; Zoccarato, Y.
2006-12-01
The 60 MeV proton beam delivered by the RADEF facility of the University of Jyväskylä (Finland) was used to measure the radiation effects on the counter components of the V0 detector of ALICE. There are the scintillator BC404, the wavelength shifting fibres BCF9929A and the optical fibres BCF98 from Bicron (Saint-Gobain). The light yield and the time resolution given by a counter of the inner ring of the V0C array, mounted within a dedicated device, were measured as a function of the radiation dose up to about 300 krad. A global light attenuation of the order of 30% can be anticipated during 10 years of ALICE running.
NASA Astrophysics Data System (ADS)
Zirour, H.; Izerrouken, M.; Sari, A.
2016-06-01
The present investigation reports the effect of 90 MeV Xe ion irradiation on neutron irradiated Al2O3 single crystals. Three irradiation experiments were performed, with neutrons only, 90 MeV Xe ions only and with neutrons followed by 90 MeV Xe ions. Neutron and 90 MeV Xe ion irradiations were performed at NUR research reactor, Algiers, Algeria and at GANIL accelerator, Caen, France respectively. After irradiation, the radiation damage was investigated by Raman spectroscopy, Fourier Transform Infrared Spectroscopy (FTIR), optical absorption measurements, and X-ray diffraction (XRD) techniques. Raman technique revealed that the concentration of the defects formed in Al2O3 samples subsequently irradiated with neutrons and 90 MeV Xe ions is lower than that formed in Al2O3 samples which were irradiated only with neutrons. This reveals the occurrence of ionization-induced recovery of the neutron damage. Furthermore, as revealed by XRD analysis, a new peak is appeared at about 2θ = 38.03° after irradiation at high fluence (>3 × 1013 Xe/cm2). It can be assigned to the formation of new lattice plane.
NASA Astrophysics Data System (ADS)
Djaloeis, A.; Alderliesten, C.; Bojowald, J.; Mayer-Böricke, C.; Oelert, W.; Turek, P.
1983-04-01
Angular distributions of 58Ni(3He, d)59Cu transitions leading to the (0.0 MeV, 32-), (0.91 MeV, 52-), and (3.04 MeV, 92+) states in 59Cu have been measured at an incident energy of 130 MeV. The experimental data have been used to study mainly the role of the 3He optical model potential ambiguity in the distorted-wave Born approximation description of the reaction. Satisfactory fits to the data are obtained using a deep helion potential in standard local zero-range calculations. For a shallow 3He potential a comparable description can be achieved if the depth of the real part of the deuteron optical potential is reduced considerably, and nonlocality as well as finite-range corrections are taken into account. Under these conditions, the use of a 3He potential constructed according to the Johnson-Soper prescription yields similar results. NUCLEAR REACTIONS 58Ni (3He, d)59Cu, E=130 MeV; measured dσ(θ)dΩ. Enriched target; DWBA analysis; discussed reaction mechanism.
LS 5039 - the counterpart of the unidentified MeV source GRO J1823-12
NASA Astrophysics Data System (ADS)
Collmar, W.; Zhang, S.
2014-05-01
Context. The COMPTEL experiment on CGRO observed the γ-ray sky at energies from 0.75 MeV to 30 MeV between April 1991 and June 2000. COMPTEL detected many γ-ray sources, among them an unidentified one labeled GRO J1823-12. It is located near l/b = 17.5°/-0.5° and positionally consistent with the prominent γ-ray binary LS 5039. Aims: LS 5039 was established as a γ-ray source at TeV energies by HESS and at GeV energies by Fermi/LAT during recent years, whose γ-ray radiation is modulated along its binary orbit. Given this new information we reanalyzed the COMPTEL data of GRO J1823-12 including an orbital-resolved analysis. Methods: We applied the standard methods, proper event selections and data binning with subsequent maximum-likelihood deconvolution, to analyze the COMPTEL data. In addition we developed a tool for selecting and binning the COMPTEL data in a phase-resolved manner. We present the orbit-averaged, as well as orbit-resolved MeV analyses, light curves, and spectra, and put them into a multifrequency context. Results: The COMPTEL data show a significant MeV source, which is positionally consistent with LS 5039, but also with other closeby Fermi/LAT sources. The orbit-resolved analysis provides strong evidence, at about the 3σ level, that the MeV flux of GRO J1823-12 is modulated along the binary orbit of about 3.9 days of LS 5039. We show that at MeV energies, the source is brighter at the orbital part around the inferior conjunction than at the part of the superior conjunction, so it is in phase with X-rays and TeV γ-rays, but in anti-phase with GeV γ-rays. The high-energy spectral energy distribution (X-rays to TeV γ-rays) shows the high-energy emission maximum of LS 5039 at MeV energies. Conclusions: We conclude that the COMPTEL source GRO J1823-12 is the counterpart of the microquasar LS 5039, at least for the majority of its MeV emission. The COMPTEL fluxes, put into multifrequency perspective, provide new constraints on the modeling of the high-energy emission pattern of the γ-ray binary LS 5039. Table 1 is available in electronic form at http://www.aanda.org
Li, W.; Thorne, R. M.; Bortnik, J.; ...
2015-09-07
In this study by determining preferential solar wind conditions leading to efficient radiation belt electron acceleration is crucial for predicting radiation belt electron dynamics. Using Van Allen Probes electron observations (>1 MeV) from 2012 to 2015, we identify a number of efficient and inefficient acceleration events separately to perform a superposed epoch analysis of the corresponding solar wind parameters and geomagnetic indices. By directly comparing efficient and inefficient acceleration events, we clearly show that prolonged southward Bz, high solar wind speed, and low dynamic pressure are critical for electron acceleration to >1 MeV energies in the heart of the outermore » radiation belt. We also evaluate chorus wave evolution using the superposed epoch analysis for the identified efficient and inefficient acceleration events and find that chorus wave intensity is much stronger and lasts longer during efficient electron acceleration events, supporting the scenario that chorus waves play a key role in MeV electron acceleration.« less
Design of a transportable high efficiency fast neutron spectrometer
Roecker, C.; Bernstein, A.; Bowden, N. S.; ...
2016-04-12
A transportable fast neutron detection system has been designed and constructed for measuring neutron energy spectra and flux ranging from tens to hundreds of MeV. The transportability of the spectrometer reduces the detector-related systematic bias between different neutron spectra and flux measurements, which allows for the comparison of measurements above or below ground. The spectrometer will measure neutron fluxes that are of prohibitively low intensity compared to the site-specific background rates targeted by other transportable fast neutron detection systems. To measure low intensity high-energy neutron fluxes, a conventional capture-gating technique is used for measuring neutron energies above 20 MeV andmore » a novel multiplicity technique is used for measuring neutron energies above 100 MeV. The spectrometer is composed of two Gd containing plastic scintillator detectors arranged around a lead spallation target. To calibrate and characterize the position dependent response of the spectrometer, a Monte Carlo model was developed and used in conjunction with experimental data from gamma ray sources. Multiplicity event identification algorithms were developed and used with a Cf-252 neutron multiplicity source to validate the Monte Carlo model Gd concentration and secondary neutron capture efficiency. The validated Monte Carlo model was used to predict an effective area for the multiplicity and capture gating analyses. For incident neutron energies between 100 MeV and 1000 MeV with an isotropic angular distribution, the multiplicity analysis predicted an effective area of 500 cm 2 rising to 5000 cm 2. For neutron energies above 20 MeV, the capture-gating analysis predicted an effective area between 1800 cm 2 and 2500 cm 2. As a result, the multiplicity mode was found to be sensitive to the incident neutron angular distribution.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roecker, C.; Bernstein, A.; Bowden, N. S.
A transportable fast neutron detection system has been designed and constructed for measuring neutron energy spectra and flux ranging from tens to hundreds of MeV. The transportability of the spectrometer reduces the detector-related systematic bias between different neutron spectra and flux measurements, which allows for the comparison of measurements above or below ground. The spectrometer will measure neutron fluxes that are of prohibitively low intensity compared to the site-specific background rates targeted by other transportable fast neutron detection systems. To measure low intensity high-energy neutron fluxes, a conventional capture-gating technique is used for measuring neutron energies above 20 MeV andmore » a novel multiplicity technique is used for measuring neutron energies above 100 MeV. The spectrometer is composed of two Gd containing plastic scintillator detectors arranged around a lead spallation target. To calibrate and characterize the position dependent response of the spectrometer, a Monte Carlo model was developed and used in conjunction with experimental data from gamma ray sources. Multiplicity event identification algorithms were developed and used with a Cf-252 neutron multiplicity source to validate the Monte Carlo model Gd concentration and secondary neutron capture efficiency. The validated Monte Carlo model was used to predict an effective area for the multiplicity and capture gating analyses. For incident neutron energies between 100 MeV and 1000 MeV with an isotropic angular distribution, the multiplicity analysis predicted an effective area of 500 cm 2 rising to 5000 cm 2. For neutron energies above 20 MeV, the capture-gating analysis predicted an effective area between 1800 cm 2 and 2500 cm 2. As a result, the multiplicity mode was found to be sensitive to the incident neutron angular distribution.« less
Sci—Thur AM: YIS - 08: Constructing an Attenuation map for a PET/MR Breast coil
DOE Office of Scientific and Technical Information (OSTI.GOV)
Patrick, John C.; Imaging, Lawson Health Research Institute, Knoxville, TN; London Regional Cancer Program, Knoxville, TN
2014-08-15
In 2013, around 23000 Canadian women and 200 Canadian men were diagnosed with breast cancer. An estimated 5100 women and 55 men died from the disease. Using the sensitivity of MRI with the selectivity of PET, PET/MRI combines anatomical and functional information within the same scan and could help with early detection in high-risk patients. MRI requires radiofrequency coils for transmitting energy and receiving signal but the breast coil attenuates PET signal. To correct for this PET attenuation, a 3-dimensional map of linear attenuation coefficients (μ-map) of the breast coil must be created and incorporated into the PET reconstruction process.more » Several approaches have been proposed for building hardware μ-maps, some of which include the use of conventional kVCT and Dual energy CT. These methods can produce high resolution images based on the electron densities of materials that can be converted into μ-maps. However, imaging hardware containing metal components with photons in the kV range is susceptible to metal artifacts. These artifacts can compromise the accuracy of the resulting μ-map and PET reconstruction; therefore high-Z components should be removed. We propose a method for calculating μ-maps without removing coil components, based on megavoltage (MV) imaging with a linear accelerator that has been detuned for imaging at 1.0MeV. Containers of known geometry with F18 were placed in the breast coil for imaging. A comparison between reconstructions based on the different μ-map construction methods was made. PET reconstructions with our method show a maximum of 6% difference over the existing kVCT-based reconstructions.« less
Radiation-assisted grafting of vinylidene chloride onto high-density polyethylene
NASA Astrophysics Data System (ADS)
Nagesh, N.; Dokhale, P. A.; Bhoraskar, V. N.
1999-06-01
6 MeV electrons and Co-60 icons/Journals/Common/gamma" ALT="gamma" ALIGN="TOP"/>-rays were used for grafting vinylidene chloride (VDC) onto high-density polyethylene (HDPE) samples. The HDPE samples were immersed in vinylidene chloride and irradiated either with Co-60 icons/Journals/Common/gamma" ALT="gamma" ALIGN="TOP"/>-rays or with 6 MeV electrons. In both cases, the radiation dose was varied in the range 1.25-7.5 kGy. The grafted samples were characterized by IR spectroscopy to obtain information about the chemical bonds and with the 14 MeV neutron activation analysis technique for estimating the number of chlorine atoms. The formation of stable bonds between the VDC molecules and the polymer chains could be achieved either with 6 MeV electrons or with Co-60 icons/Journals/Common/gamma" ALT="gamma" ALIGN="TOP"/>-rays. Both the number of chlorine atoms and the sample-surface conductivity increased with the radiation dose but the increases achieved with 6 MeV electrons were greater than those achieved with Co-60 icons/Journals/Common/gamma" ALT="gamma" ALIGN="TOP"/>-rays.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mynbaev, K. D., E-mail: mynkad@mail.ioffe.ru; Zablotsky, S. V.; Shilyaev, A. V.
Defects in mercury-cadmium-telluride heteroepitaxial structures (with 0.3 to 0.4 molar fraction of cadmium telluride) grown by molecular-beam epitaxy on silicon substrates are studied. The low-temperature photoluminescence method reveals that there are comparatively deep levels with energies of 50 to 60 meV and shallower levels with energies of 20 to 30 meV in the band gap. Analysis of the temperature dependence of the minority carrier lifetime demonstrates that this lifetime is controlled by energy levels with an energy of ∼30 meV. The possible relationship between energy states and crystal-structure defects is discussed.
Inelastic scattering of 61 MeV protons by pb-207
NASA Technical Reports Server (NTRS)
Owais, M.
1976-01-01
Differential cross sections for the excitation of the first four neutron-hole states and the doublet at 2.61 MeV by 61.2 MeV protons were measured. The data are analyzed in terms of both a purely collective model description and a microscopic model supplemented by macroscopic core polarization. A realistic two-body interaction is used and knock-on amplitudes are included. Core polarization is found to be important but represents a relatively smaller contribution than in most nuclei previously studied. A parallel analysis of similar data at lower proton bombarding energies reveals a surprisingly strong energy dependence of the reaction mechanisms.
Structural analysis and evaluation of actual PC bridge using 950 keV/3.95 MeV X-band linacs
NASA Astrophysics Data System (ADS)
Takeuchi, H.; Yano, R.; Ozawa, I.; Mitsuya, Y.; Dobashi, K.; Uesaka, M.; Kusano, J.; Oshima, Y.; Ishida, M.
2017-07-01
In Japan, bridges constructed during the strong economic growth era are facing an aging problem and advanced maintenance methods have become strongly required recently. To meet this demand, we develop the on-site inspection system using 950 keV/3.95 MeV X-band (9.3 GHz) linac X-ray sources. These systems can visualize in seconds the inner states of bridges, including cracks of concrete, location and state of tendons (wires) and other imperfections. At the on-site inspections, 950 keV linac exhibited sufficient performance. But, for thicker concrete, it is difficult to visualize the internal state by 950 keV linac. Therefore, we proceeded the installation of 3.95 MeV linac for on-site bridge inspection. In addition, for accurate evaluation, verification on the parallel motion CT technique and FEM analysis are in progress.
NASA Technical Reports Server (NTRS)
Baron, N.; Leonard, R. F.; Stewart, W. M.; Fink, C. L.; Christensen, P. R.; Nickles, J.; Thorsteinsen, T. F.
1972-01-01
Deuterons of 13-MeV incident energy were scattered from Zr-92(d,p)Zr-93. The Zr-92(d,p)Zr-93 data analysis resulted in the location of 47 levels up to an excitation energy of 4.84 MeV, and the spins of 43 of these levels were identified. Essentially all the strength of the 2d5/2, 3s1/2, 2d3/2, and 1g7/2 shells was observed; and the excitation energy of their centroids was computed to be 0.00, 1.21, 2.23, and 2.37 MeV, respectively. Also, 43 percent of the 1h11/2 strength, 21 percent of the 2f7/2 strength, and 3 percent of the 3p3/2 strength were observed. In addition, the Zr-92(d,t)Zr-91 data analysis resulted in the location of 26 levels up to an excitation energy of 4.01 MeV, and the spins of 21 of these levels were identified. Most of the expected strength of the 2d5/2 and 1g9/2 shells was obtained, and the excitation energy of their centroids was computed to be 0.31 and 3.19 MeV, respectively. In addition, six l=1 states are populated belonging to either the 2p1/2 or 2p3/2 shells.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yochmowitz, M.G.; Wood, D.H.; Salmon, Y.L.
1983-01-01
A radiation primate colony of 57 controls and 301 (217 proton) exposed subjects has been followed since 1964. Lifespan of both the exposed and, more specifically, the proton-exposed subjects in the chronic colony was shortened. Energies of 55 MeV and greater decreased life span as did doses in excess of 360 rads. Females were more sensitive to lower doses than males. They died earlier in doses as low as 25-113 rads and in all energies tested except 55 MeV. Survival curve analysis found no difference among the onset of death in the 3 highest energies (138, 400, and 2300 Mev);more » however, its onset was earlier in the 32-MeV exposure and later in the 55-MeV exposure and later in the 55-MeV exposure than the total penetrating energies (greater than or equal to 138 MeV). Dose ordering effects were evident. In contrast to the controls, mortality rates began to accelerate at approx. 8 years in the 360-400-rad group; at approx. 2 years in the 500-650-rad group and approx. 1 year in the 800-rad group. The leading causes of death among the proton-exposed animals were primary infections (approx. 30%), endometriosis (25%), and organ degeneration (approx. 17%). Malignant tumors accounted for 18% of the deaths. If endometriosis is included in this group, the mortality from all forms of neoplastic conditions is 43% in the proton-exposed animals.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yochmowitz, M.G.; Wood, D.H.; Salmon, Y.L.
1983-01-01
A radiation primate colony of 57 controls and 301 (217 proton) exposed subjects has been followed since 1964. Lifespan of both the exposed and, more specifically, the proton-exposed subjects in the chronic colony was shortened. Energies of 55 MeV and greater decreased life span as did doses in excess of 360 rads. Females were more sensitive to lower doses than males. They died earlier in doses as low as 25-113 rads and in all energies tested except 55 MeV. Survival curve analysis found no difference among the onset of death in the 3 highest energies (138, 400, and 2300 Mev);more » however, its onset was earlier in the 32-MeV exposure and later in the 55-MeV exposure and later in the 55-MeV exposure than the total penetrating energies (greater than or equal to 138 MeV). Dose ordering effects were evident. In contrast to the controls, mortality rates began to accelerate at approx. 8 years in the 360-400-rad group; at approx. 2 years in the 500-650-rad group and approx. 1 year in the 800-rad group. The leading causes of death among the proton-exposed animals were primary infections (approx. 30%), endometriosis (25%), and organ degeneration (approx. 17%). Malignant tumors accounted for 18% of the deaths. If endometriosis is included in this group, the mortality from all forms of neoplastic conditions is 43% in the proton-exposed animals.« less
Study of η (1475 ) and X (1835 ) in radiative J /ψ decays to γ ϕ
NASA Astrophysics Data System (ADS)
Ablikim, M.; Achasov, M. N.; Ahmed, S.; Albayrak, O.; Albrecht, M.; Alekseev, M.; Ambrose, D. J.; Amoroso, A.; An, F. F.; An, Q.; Bai, J. Z.; Bakina, O.; Baldini Ferroli, R.; Ban, Y.; Bennett, D. W.; Bennett, J. V.; Berger, N.; Bertani, M.; Bettoni, D.; Bian, J. M.; Bianchi, F.; Boger, E.; Boyko, I.; Briere, R. A.; Cai, H.; Cai, X.; Cakir, O.; Calcaterra, A.; Cao, G. F.; Cetin, S. A.; Chai, J.; Chang, J. F.; Chelkov, G.; Chen, G.; Chen, H. S.; Chen, J. C.; Chen, M. L.; Chen, P. L.; Chen, S. J.; Chen, X. R.; Chen, Y. B.; Chu, X. K.; Cibinetto, G.; Dai, H. L.; Dai, J. P.; Dbeyssi, A.; Dedovich, D.; Deng, Z. Y.; Denig, A.; Denysenko, I.; Destefanis, M.; de Mori, F.; Ding, Y.; Dong, C.; Dong, J.; Dong, L. Y.; Dong, M. Y.; Dorjkhaidav, O.; Dou, Z. L.; Du, S. X.; Duan, P. F.; Fang, J.; Fang, S. S.; Fang, X.; Fang, Y.; Farinelli, R.; Fava, L.; Fegan, S.; Feldbauer, F.; Felici, G.; Feng, C. Q.; Fioravanti, E.; Fritsch, M.; Fu, C. D.; Gao, Y. G.; Gao, Q.; Gao, X. L.; Gao, Y.; Gao, Z.; Garzia, I.; Goetzen, K.; Gong, L.; Gong, W. X.; Gradl, W.; Greco, M.; Gu, M. H.; Gu, S.; Gu, Y. T.; Guo, A. Q.; Guo, L. B.; Guo, R. P.; Guo, Y. P.; Haddadi, Z.; Hafner, A.; Han, S.; Hao, X. Q.; Harris, F. A.; He, K. L.; He, X. Q.; Heinsius, F. H.; Held, T.; Heng, Y. K.; Holtmann, T.; Hou, Z. L.; Hu, C.; Hu, H. M.; Hu, T.; Hu, Y.; Huang, G. S.; Huang, J. S.; Huang, X. T.; Huang, X. Z.; Huang, Z. L.; Hussain, T.; Ikegami Andersson, W.; Ji, Q.; Ji, Q. P.; Ji, X. B.; Ji, X. L.; Jiang, X. S.; Jiang, X. Y.; Jiao, J. B.; Jiao, Z.; Jin, D. P.; Jin, S.; Johansson, T.; Julin, A.; Kalantar-Nayestanaki, N.; Kang, X. L.; Kang, X. S.; Kavatsyuk, M.; Ke, B. C.; Khan, Tabassum; Kiese, P.; Kliemt, R.; Kloss, B.; Kolcu, O. B.; Kopf, B.; Kornicer, M.; Kupsc, A.; Kühn, W.; Lange, J. S.; Lara, M.; Larin, P.; Lavezzi, L.; Leithoff, H.; Leng, C.; Li, C.; Li, Cheng; Li, D. M.; Li, F.; Li, F. Y.; Li, G.; Li, H. B.; Li, H. J.; Li, J. C.; Li, Jin; Li, K.; Li, K.; Li, Lei; Li, P. L.; Li, P. R.; Li, Q. Y.; Li, T.; Li, W. D.; Li, W. G.; Li, X. L.; Li, X. N.; Li, X. Q.; Li, Z. B.; Liang, H.; Liang, Y. F.; Liang, Y. T.; Liao, G. R.; Lin, D. X.; Liu, B.; Liu, B. J.; Liu, C. X.; Liu, D.; Liu, F. H.; Liu, Fang; Liu, Feng; Liu, H. B.; Liu, H. H.; Liu, H. H.; Liu, H. M.; Liu, J. B.; Liu, J. P.; Liu, J. Y.; Liu, K.; Liu, K. Y.; Liu, Ke; Liu, L. D.; Liu, P. L.; Liu, Q.; Liu, S. B.; Liu, X.; Liu, Y. B.; Liu, Y. Y.; Liu, Z. A.; Liu, Zhiqing; Loehner, H.; Long, Y. F.; Lou, X. C.; Lu, H. J.; Lu, J. G.; Lu, Y.; Lu, Y. P.; Luo, C. L.; Luo, M. X.; Luo, T.; Luo, X. L.; Lyu, X. R.; Ma, F. C.; Ma, H. L.; Ma, L. L.; Ma, M. M.; Ma, Q. M.; Ma, T.; Ma, X. N.; Ma, X. Y.; Ma, Y. M.; Maas, F. E.; Maggiora, M.; Malik, Q. A.; Mao, Y. J.; Mao, Z. P.; Marcello, S.; Messchendorp, J. G.; Mezzadri, G.; Min, J.; Min, T. J.; Mitchell, R. E.; Mo, X. H.; Mo, Y. J.; Morales Morales, C.; Morello, G.; Muchnoi, N. Yu.; Muramatsu, H.; Musiol, P.; Nefedov, Y.; Nerling, F.; Nikolaev, I. B.; Ning, Z.; Nisar, S.; Niu, S. L.; Niu, X. Y.; Olsen, S. L.; Ouyang, Q.; Pacetti, S.; Pan, Y.; Patteri, P.; Pelizaeus, M.; Pellegrino, J.; Peng, H. P.; Peters, K.; Pettersson, J.; Ping, J. L.; Ping, R. G.; Poling, R.; Prasad, V.; Qi, H. R.; Qi, M.; Qian, S.; Qiao, C. F.; Qin, J. J.; Qin, N.; Qin, X. S.; Qin, Z. H.; Qiu, J. F.; Rashid, K. H.; Redmer, C. F.; Ripka, M.; Rong, G.; Rosner, Ch.; Ruan, X. D.; Sarantsev, A.; Savrié, M.; Schnier, C.; Schoenning, K.; Shan, W.; Shao, M.; Shen, C. P.; Shen, P. X.; Shen, X. Y.; Sheng, H. Y.; Song, J. J.; Song, X. Y.; Sosio, S.; Spataro, S.; Sun, G. X.; Sun, J. F.; Sun, S. S.; Sun, X. H.; Sun, Y. J.; Sun, Y. K.; Sun, Y. Z.; Sun, Z. J.; Sun, Z. T.; Tang, C. J.; Tang, X.; Tapan, I.; Thorndike, E. H.; Tiemens, M.; Tsednee, Ts; Uman, I.; Varner, G. S.; Wang, B.; Wang, B. L.; Wang, D.; Wang, D. Y.; Wang, Dan; Wang, K.; Wang, L. L.; Wang, L. S.; Wang, M.; Wang, P.; Wang, P. L.; Wang, W. P.; Wang, X. F.; Wang, Y. D.; Wang, Y. F.; Wang, Y. Q.; Wang, Z.; Wang, Z. G.; Wang, Z. H.; Wang, Z. Y.; Wang, Z. Y.; Weber, T.; Wei, D. H.; Weidenkaff, P.; Wen, S. P.; Wiedner, U.; Wolke, M.; Wu, L. H.; Wu, L. J.; Wu, Z.; Xia, L.; Xia, Y.; Xiao, D.; Xiao, Y. J.; Xiao, Z. J.; Xie, Y. G.; Xie, Yuehong; Xiong, X. A.; Xiu, Q. L.; Xu, G. F.; Xu, J. J.; Xu, L.; Xu, Q. J.; Xu, Q. N.; Xu, X. P.; Yan, L.; Yan, W. B.; Yan, W. C.; Yan, Y. H.; Yang, H. J.; Yang, H. X.; Yang, L.; Yang, Y. H.; Yang, Y. X.; Ye, M.; Ye, M. H.; Yin, J. H.; You, Z. Y.; Yu, B. X.; Yu, C. X.; Yu, J. S.; Yuan, C. Z.; Yuan, Y.; Yuncu, A.; Zafar, A. A.; Zeng, Y.; Zeng, Z.; Zhang, B. X.; Zhang, B. Y.; Zhang, C. C.; Zhang, D. H.; Zhang, H. H.; Zhang, H. Y.; Zhang, J.; Zhang, J. L.; Zhang, J. Q.; Zhang, J. W.; Zhang, J. Y.; Zhang, J. Z.; Zhang, K.; Zhang, L.; Zhang, S. Q.; Zhang, X. Y.; Zhang, Y.; Zhang, Y.; Zhang, Y. H.; Zhang, Y. T.; Zhang, Yu; Zhang, Z. H.; Zhang, Z. P.; Zhang, Z. Y.; Zhao, G.; Zhao, J. W.; Zhao, J. Y.; Zhao, J. Z.; Zhao, Lei; Zhao, Ling; Zhao, M. G.; Zhao, Q.; Zhao, S. J.; Zhao, T. C.; Zhao, Y. B.; Zhao, Z. G.; Zhemchugov, A.; Zheng, B.; Zheng, J. P.; Zheng, W. J.; Zheng, Y. H.; Zhong, B.; Zhou, L.; Zhou, X.; Zhou, X. K.; Zhou, X. R.; Zhou, X. Y.; Zhou, Y. X.; Zhu, K.; Zhu, K. J.; Zhu, S.; Zhu, S. H.; Zhu, X. L.; Zhu, Y. C.; Zhu, Y. S.; Zhu, Z. A.; Zhuang, J.; Zotti, L.; Zou, B. S.; Zou, J. H.; Besiii Collaboration
2018-03-01
The decay J /ψ →γ γ ϕ is studied using a sample of 1.31 ×109 J /ψ events collected with the BESIII detector. Two structures around 1475 MeV /c2 and 1835 MeV /c2 are observed in the γ ϕ invariant mass spectrum for the first time. With a fit on the γ ϕ invariant mass, which takes into account the interference between the two structures, and a simple analysis of the angular distribution, the structure around 1475 MeV /c2 is found to favor an assignment as the η (1475 ) and the mass and width for the structure around 1835 MeV /c2 are consistent with the X (1835 ). The statistical significances of the two structures are 13.5 σ and 6.3 σ , respectively. The results indicate that both η (1475 ) and X (1835 ) contain a sizeable s s ¯ component.
A direct electron detector for time-resolved MeV electron microscopy
Vecchione, T.; Denes, P.; Jobe, R. K.; ...
2017-03-15
The introduction of direct electron detectors enabled the structural biology revolution of cryogenic electron microscopy. Direct electron detectors are now expected to have a similarly dramatic impact on time-resolved MeV electron microscopy, particularly by enabling both spatial and temporal jitter correction. Here in this paper, we report on the commissioning of a direct electron detector for time-resolved MeV electron microscopy. The direct electron detector demonstrated MeV single electron sensitivity and is capable of recording megapixel images at 180 Hz. The detector has a 15-bit dynamic range, better than 30-μm spatial resolution and less than 20 analogue-to-digital converter count RMS pixelmore » noise. The unique capabilities of the direct electron detector and the data analysis required to take advantage of these capabilities are presented. The technical challenges associated with generating and processing large amounts of data are also discussed.« less
Constraints on the Genetic and Antigenic Variability of Measles Virus.
Beaty, Shannon M; Lee, Benhur
2016-04-21
Antigenic drift and genetic variation are significantly constrained in measles virus (MeV). Genetic stability of MeV is exceptionally high, both in the lab and in the field, and few regions of the genome allow for rapid genetic change. The regions of the genome that are more tolerant of mutations (i.e., the untranslated regions and certain domains within the N, C, V, P, and M proteins) indicate genetic plasticity or structural flexibility in the encoded proteins. Our analysis reveals that strong constraints in the envelope proteins (F and H) allow for a single serotype despite known antigenic differences among its 24 genotypes. This review describes some of the many variables that limit the evolutionary rate of MeV. The high genomic stability of MeV appears to be a shared property of the Paramyxovirinae, suggesting a common mechanism that biologically restricts the rate of mutation.
Constraints on the Genetic and Antigenic Variability of Measles Virus
Beaty, Shannon M.; Lee, Benhur
2016-01-01
Antigenic drift and genetic variation are significantly constrained in measles virus (MeV). Genetic stability of MeV is exceptionally high, both in the lab and in the field, and few regions of the genome allow for rapid genetic change. The regions of the genome that are more tolerant of mutations (i.e., the untranslated regions and certain domains within the N, C, V, P, and M proteins) indicate genetic plasticity or structural flexibility in the encoded proteins. Our analysis reveals that strong constraints in the envelope proteins (F and H) allow for a single serotype despite known antigenic differences among its 24 genotypes. This review describes some of the many variables that limit the evolutionary rate of MeV. The high genomic stability of MeV appears to be a shared property of the Paramyxovirinae, suggesting a common mechanism that biologically restricts the rate of mutation. PMID:27110809
A direct electron detector for time-resolved MeV electron microscopy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vecchione, T.; Denes, P.; Jobe, R. K.
The introduction of direct electron detectors enabled the structural biology revolution of cryogenic electron microscopy. Direct electron detectors are now expected to have a similarly dramatic impact on time-resolved MeV electron microscopy, particularly by enabling both spatial and temporal jitter correction. Here we report on the commissioning of a direct electron detector for time-resolved MeV electron microscopy. The direct electron detector demonstrated MeV single electron sensitivity and is capable of recording megapixel images at 180 Hz. The detector has a 15-bit dynamic range, better than 30-μmμm spatial resolution and less than 20 analogue-to-digital converter count RMS pixel noise. The uniquemore » capabilities of the direct electron detector and the data analysis required to take advantage of these capabilities are presented. The technical challenges associated with generating and processing large amounts of data are also discussed.« less
A direct electron detector for time-resolved MeV electron microscopy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vecchione, T.; Denes, P.; Jobe, R. K.
The introduction of direct electron detectors enabled the structural biology revolution of cryogenic electron microscopy. Direct electron detectors are now expected to have a similarly dramatic impact on time-resolved MeV electron microscopy, particularly by enabling both spatial and temporal jitter correction. Here in this paper, we report on the commissioning of a direct electron detector for time-resolved MeV electron microscopy. The direct electron detector demonstrated MeV single electron sensitivity and is capable of recording megapixel images at 180 Hz. The detector has a 15-bit dynamic range, better than 30-μm spatial resolution and less than 20 analogue-to-digital converter count RMS pixelmore » noise. The unique capabilities of the direct electron detector and the data analysis required to take advantage of these capabilities are presented. The technical challenges associated with generating and processing large amounts of data are also discussed.« less
AGILE OBSERVATIONS OF THE 'SOFT' GAMMA-RAY PULSAR PSR B1509 - 58
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pilia, M.; Pellizzoni, A.; Esposito, P.
2010-11-01
We present the results of new AGILE observations of PSR B1509 - 58 performed over a period of {approx}2.5 years following the detection obtained with a subset of the present data. The modulation significance of the light curve above 30 MeV is at a 5{sigma} confidence level and the light curve is similar to those found earlier by COMPTEL up to 30 MeV: a broad asymmetric first peak reaching its maximum 0.39 {+-} 0.02 cycles after the radio peak plus a second peak at 0.94 {+-} 0.03. The gamma-ray spectral energy distribution of the pulsed flux detected by COMPTEL andmore » AGILE is well described by a power law (photon index {alpha} = 1.87 {+-} 0.09) with a remarkable cutoff at E{sub c} = 81 {+-} 20 MeV, representing the softest spectrum observed among gamma-ray pulsars so far. The pulsar luminosity at E > 1 MeV is L{sub {gamma}} = 4.2{sup +0.5}{sub -0.2} x 10{sup 35} erg s{sup -1}, assuming a distance of 5.2 kpc, which implies a spin-down conversion efficiency to gamma rays of {approx}0.03. The unusual soft break in the spectrum of PSR B1509 - 58 has been interpreted in the framework of polar cap models as a signature of the exotic photon-splitting process in the strong magnetic field of this pulsar. In this interpretation, our spectrum constrains the magnetic altitude of the emission point(s) at 3 km above the neutron star surface, implying that the attenuation may not be as strong as formerly suggested because pair production can substitute photon splitting into regions of the magnetosphere where the magnetic field becomes too low to sustain photon splitting. In the case of an outer-gap scenario or the two-pole caustic model, better constraints on the geometry of the emission would be needed from the radio band in order to establish whether the conditions required by the models to reproduce AGILE light curves and spectra match the polarization measurements.« less
Upper limit on the inner radiation belt MeV electron intensity.
Li, X; Selesnick, R S; Baker, D N; Jaynes, A N; Kanekal, S G; Schiller, Q; Blum, L; Fennell, J; Blake, J B
2015-02-01
No instruments in the inner radiation belt are immune from the unforgiving penetration of the highly energetic protons (tens of MeV to GeV). The inner belt proton flux level, however, is relatively stable; thus, for any given instrument, the proton contamination often leads to a certain background noise. Measurements from the Relativistic Electron and Proton Telescope integrated little experiment on board Colorado Student Space Weather Experiment CubeSat, in a low Earth orbit, clearly demonstrate that there exist sub-MeV electrons in the inner belt because their flux level is orders of magnitude higher than the background, while higher-energy electron (>1.6 MeV) measurements cannot be distinguished from the background. Detailed analysis of high-quality measurements from the Relativistic Electron and Proton Telescope on board Van Allen Probes, in a geo-transfer-like orbit, provides, for the first time, quantified upper limits on MeV electron fluxes in various energy ranges in the inner belt. These upper limits are rather different from flux levels in the AE8 and AE9 models, which were developed based on older data sources. For 1.7, 2.5, and 3.3 MeV electrons, the upper limits are about 1 order of magnitude lower than predicted model fluxes. The implication of this difference is profound in that unless there are extreme solar wind conditions, which have not happened yet since the launch of Van Allen Probes, significant enhancements of MeV electrons do not occur in the inner belt even though such enhancements are commonly seen in the outer belt. Quantified upper limit of MeV electrons in the inner beltActual MeV electron intensity likely much lower than the upper limitMore detailed understanding of relativistic electrons in the magnetosphere.
Upper limit on the inner radiation belt MeV electron intensity
Li, X; Selesnick, RS; Baker, DN; Jaynes, AN; Kanekal, SG; Schiller, Q; Blum, L; Fennell, J; Blake, JB
2015-01-01
No instruments in the inner radiation belt are immune from the unforgiving penetration of the highly energetic protons (tens of MeV to GeV). The inner belt proton flux level, however, is relatively stable; thus, for any given instrument, the proton contamination often leads to a certain background noise. Measurements from the Relativistic Electron and Proton Telescope integrated little experiment on board Colorado Student Space Weather Experiment CubeSat, in a low Earth orbit, clearly demonstrate that there exist sub-MeV electrons in the inner belt because their flux level is orders of magnitude higher than the background, while higher-energy electron (>1.6 MeV) measurements cannot be distinguished from the background. Detailed analysis of high-quality measurements from the Relativistic Electron and Proton Telescope on board Van Allen Probes, in a geo-transfer-like orbit, provides, for the first time, quantified upper limits on MeV electron fluxes in various energy ranges in the inner belt. These upper limits are rather different from flux levels in the AE8 and AE9 models, which were developed based on older data sources. For 1.7, 2.5, and 3.3 MeV electrons, the upper limits are about 1 order of magnitude lower than predicted model fluxes. The implication of this difference is profound in that unless there are extreme solar wind conditions, which have not happened yet since the launch of Van Allen Probes, significant enhancements of MeV electrons do not occur in the inner belt even though such enhancements are commonly seen in the outer belt. Key Points Quantified upper limit of MeV electrons in the inner belt Actual MeV electron intensity likely much lower than the upper limit More detailed understanding of relativistic electrons in the magnetosphere PMID:26167446
Harvala, Heli; Wiman, Åsa; Wallensten, Anders; Zakikhany, Katherina; Englund, Hélène; Brytting, Maria
2016-02-15
It is increasingly difficult to differentiate measles viruses (MeVs) relating to certain outbreaks on the basis of the nucleoprotein (N) gene sequence only, as the diversity of circulating MeV strains has decreased. We studied genomic regions that could provide better molecular discrimination between epidemiologically linked and unlinked MeV variants identified in Sweden during 2013-2014. The hemagglutinin (H) gene and hypervariable region between the fusion and matrix genes (MF-HVR) from 53 MeV-positive samples were amplified and sequenced. Data on phylogenetic clustering of MeVs on the basis of N, H, and MF-HVR sequences were compared to epidemiological data. MeVs were genotyped: 27 were B3, and 26 were D8. One genotype B3 cluster based on the N gene sequence contained epidemiologically unrelated viruses from 4 outbreaks, whereas analysis of H and MF-HVR sequences separated them into phylogenetic clusters consistent with the epidemiological data. Similarly, the single cluster of viruses with a genotype D8 N gene could be divided into the 5 outbreak groups on the basis of the phylogeny of MF-HVR sequences. A detailed picture of MeV circulation with more-defined links between outbreaks was obtained by sequencing the H gene and MF-HVR. Further identification and better genetic characterization of MeVs internationally is essential in identifying sources and routes of MeV spread within and beyond Europe in the elimination end game. © The Author 2015. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.
Detection of fissionable material in cargo containers using active neutron interrogation
NASA Astrophysics Data System (ADS)
Church, Jennifer
2006-10-01
Roughly 6 million cargo containers will be shipped to U.S. seaports in a single year, each container carrying up to 30 tons of freight in varied configurations. Highly enriched uranium and other fissionable material concealed inside these containers is a challenge for existing portal monitors, due in part to the attenuation of signals in the cargo. A system is currently being developed to overcome these challenges without slowing the flow of commerce through the port, keeping the likelihood of false-negative and false- positive detections to a minimum. The technique utilizes a neutron beam to induce fission, and a wall of plastic scintillators to detect subsequent delayed high-energy γ- rays after β-decay of the fission products Decay curves utilizing these delayed γ-rays with energies above 3 MeV are an efficient diagnostic. New experimental work using a 3-7 MeV broad spectrum neutron source will be presented and compared to simulations and past experimental results. This work is performed under the auspices of the U.S. Department of Energy by the University of California, Lawrence Livermore National Laboratory contract No. W-7405-Eng-4, UCRL-ABS-219231. E.B.,orman et al., Nucl. Instr. Methods Phys. Res. A, 521, 608 (2004).
Experimental study of ΔI=1 bands in In111
NASA Astrophysics Data System (ADS)
Banerjee, P.; Ganguly, S.; Pradhan, M. K.; Sharma, H. P.; Muralithar, S.; Singh, R. P.; Bhowmik, R. K.
2011-02-01
The two ΔI=1 bands in In111, built upon the 3461.0 and 4931.8 keV states, have been studied. The bands were populated in the reaction Mo100(F19,α4nγ) at a beam energy of 105 MeV. Mean lifetimes of nine states, four in the first and five in the second band, have been determined for the first time from Doppler shift attenuation data. The deduced B(M1) rates and their behavior as a function of level spin support the interpretation of these bands within the framework of the shears mechanism. The geometrical model of Machiavelli has been used to derive the effective gyromagnetic ratios for the two bands.
McCune, D.A.
1964-03-17
A method and device for measurement of integrated fast neutron flux in the presence of a large thermal neutron field are described. The device comprises a thorium wire surrounded by a thermal neutron attenuator that is, in turn, enclosed by heat-resistant material. The method consists of irradiating the device in a neutron field whereby neutrons with energies in excess of 1.1 Mev cause fast fissions in the thorium, then removing the thorium wire, separating the cesium-137 fission product by chemical means from the thorium, and finally counting the radioactivity of the cesium to determine the number of fissions which have occurred so that the integrated fast flux may be obtained. (AEC)
Development of a 3D-Printed Collimated 90Sr Beta Source
NASA Astrophysics Data System (ADS)
Daniel, Byron; NuDot Collaboration
2017-09-01
Collimated beta particle sources based on 90Sr are common calibration sources for atomic decay detector research and development. Due to the short attenuation length of beta particles in matter, the exact geometry of a collimator can drastically change the rate and energy of beta particles exiting the source. 3D printing allows for the quick and easy prototyping of collimators with custom geometries. I will describe the development of a collimator that interfaces directly to a quartz cuvette for the characterization of liquid scintillator cocktails. Future work will include developing a source for the NuDot detector which aims to reconstruct MeV electrons using the separation of Cherenkov and scintillation light. MIT Summer Research Program.
NASA Astrophysics Data System (ADS)
Obaid, Shamsan S.; Sayyed, M. I.; Gaikwad, D. K.; Pawar, Pravina. P.
2018-07-01
In the present work, the mass attenuation coefficient μ/ρ is investigated experimentally and theoretically for seven rocks (olivine basalt, green marble, jet black granite, telphone black granite, cuddapah limestone, white marble and pink marble). The rock samples were collected from different places of India. The mass attenuation coefficients of the samples were measured experimentally at photon energies of radioisotopes Co57 (122 keV), Ba133 (356 keV), 22Na (511 and 1275 keV), Cs137 (662 keV), Mn54 (840 keV), and Co60 (1330 keV). Theoretically, the simulation results of μ/ρ using both XCOM and MCNP5 codes were compared with experimental results and a satisfactory agreement was observed. Total atomic cross sections (σt,a) electronic cross sections (σt,e), effective atomic number (Zeff), electron density (Ne) and half value layer (HVL) were evaluated using the obtained μ/ρ values for investigated rocks. The HVL values for the selected rocks were compared with some common shielding concretes. Moreover, by Geometric Progression method (G-P) exposure buildup factor (EBF) and energy absorption buildup factor (EABF) values were calculated for incident photon energy 0.015-15 MeV up to penetration depths of 40 mean free paths. The results show that among the studied rocks pink marble possesses superior shielding properties for γ-ray. This work was carried out to explore the advantage of utilizing the selected rocks in engineering structures and building construction to shield gamma-rays.
NASA Astrophysics Data System (ADS)
Qin, Huaili; Yang, Guang; Kuang, Shan; Wang, Qiang; Liu, Jingjing; Zhang, Xiaomin; Li, Cancan; Han, Zhiwei; Li, Yuanjing
2018-02-01
The present project will adopt the principle and technology of X-ray imaging to quickly measure the mass thickness (wherein the mass thickness of the item =density of the item × thickness of the item) of the irradiated items and thus to determine whether the packaging size and inside location of the item will meet the requirements for treating thickness upon electron beam irradiation processing. The development of algorithm of X-ray mass thickness detector as well as the prediction of dose distribution have been completed. The development of the algorithm was based on the X-ray attenuation. 4 standard modules, Al sheet, Al ladders, PMMA sheet and PMMA ladders, were selected for the algorithm development. The algorithm was optimized until the error between tested mass thickness and standard mass thickness was less than 5%. Dose distribution of all energy (1-10 MeV) for each mass thickness was obtained using Monte-carlo method and used for the analysis of dose distribution, which provides the information of whether the item will be penetrated or not, as well as the Max. dose, Min. dose and DUR of the whole item.
Design upgrades to the DIII-D gamma ray imager
NASA Astrophysics Data System (ADS)
Lvovskiy, A.; Cooper, C. M.; Eidietis, N. W.; Pace, D.; Paz-Soldan, C.
2016-10-01
Generation of runaway electrons (RE) in tokamak disruptions can cause damage of plasma facing components. RE studies are necessary in order to provide a reliable mechanism of RE mitigation. For that task a gamma ray imager (GRI) has been developed for DIII-D. It measures the bremsstrahlung emission by RE providing information on RE energy spectrum and RE distribution across a poloidal cross-section. The GRI consists of a lead pinhole camera illuminating a 2D array of 30 BGO detectors placed in the DIII-D mid-plane. First results showed the successful measurements of RE energy spectra in the range 1 - 60 MeV with time resolution 100 μs. They have been obtained in the low-flux quiescent RE regime via pulse-high analysis. The measurements in the high gamma flux post-disruption RE regime showed strong signal saturation. Here we present GRI design upgrades towards signal attenuation and better detector shielding including Monte-Carlo Neutral Particle modeling of GRI irradiation, as well as improved calibration techniques and options to improve electronic noise rejection. Work supported by US DOE under DE-AC05-06OR23100 and DE-FC02-04ER54698.
Cross-shell excitations from the f p shell: Lifetime measurements in 61Zn
NASA Astrophysics Data System (ADS)
Queiser, M.; Vogt, A.; Seidlitz, M.; Reiter, P.; Togashi, T.; Shimizu, N.; Utsuno, Y.; Otsuka, T.; Honma, M.; Petkov, P.; Arnswald, K.; Altenkirch, R.; Birkenbach, B.; Blazhev, A.; Braunroth, T.; Dewald, A.; Eberth, J.; Fransen, C.; Fu, B.; Hess, H.; Hetzenegger, R.; Hirsch, R.; Jolie, J.; Karayonchev, V.; Kaya, L.; Lewandowski, L.; Müller-Gatermann, C.; Régis, J.-M.; Rosiak, D.; Schneiders, D.; Siebeck, B.; Steinbach, T.; Wolf, K.; Zell, K.-O.
2017-10-01
Lifetimes of excited states in the neutron-deficient nucleus 61Zn were measured employing the recoil-distance Doppler-shift (RDDS) and the electronic fast-timing methods at the University of Cologne. The nucleus of interest was populated as an evaporation residue in 40Ca(24Mg,n 2 p )61Zn and 58Ni(α ,n )61Zn reactions at 67 and 19 MeV, respectively. Five lifetimes were measured for the first time, including the lifetime of the 5 /21- isomer at 124 keV. Short lifetimes from the RDDS analysis are corrected for Doppler-shift attenuation (DSA) in the target and stopper foils. Ambiguous observations in previous measurements were resolved. The obtained lifetimes are compared to predictions from different sets of shell-model calculations in the f p , f5 /2p g9 /2 , and multishell f p -g9 /2d5 /2 model spaces. The band built on the 9 /21+ state exhibits a prolate deformation with β ≈0.24 . Especially, the inclusion of cross-shell excitation into the 1 d5 /2 orbital is found to be decisive for the description of collectivity in the first excited positive-parity band.
Preliminary Monte Carlo calculations for the UNCOSS neutron-based explosive detector
NASA Astrophysics Data System (ADS)
Eleon, C.; Perot, B.; Carasco, C.
2010-07-01
The goal of the FP7 UNCOSS project (Underwater Coastal Sea Surveyor) is to develop a non destructive explosive detection system based on the associated particle technique, in view to improve the security of coastal area and naval infrastructures where violent conflicts took place. The end product of the project will be a prototype of a complete coastal survey system, including a neutron-based sensor capable of confirming the presence of explosives on the sea bottom. A 3D analysis of prompt gamma rays induced by 14 MeV neutrons will be performed to identify elements constituting common military explosives, such as C, N and O. This paper presents calculations performed with the MCNPX computer code to support the ongoing design studies performed by the UNCOSS collaboration. Detection efficiencies, time and energy resolutions of the possible gamma-ray detectors are compared, which show NaI(Tl) or LaBr 3(Ce) scintillators will be suitable for this application. The effect of neutron attenuation and scattering in the seawater, influencing the counting statistics and signal-to-noise ratio, are also studied with calculated neutron time-of-flight and gamma-ray spectra for an underwater TNT target.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shubin, Yu.N.
1996-06-01
The calculation and analysis of the nuclei concentrations and long-lived residual radioactivity accumulated in Pb, Pb-Bi and Hg targets irradiated by 800 MeV, 30 mA proton beam have been performed. The dominating components to the total radioactivity of radionuclides resulting from fission and spallation reactions and radiative capture by both target nuclei and accumulated radioactive nuclei for various irradiation and cooling times were analyzed. The estimations of spectral component contributions of neutron and proton fluxes to the accumulated activity were carried out. The contributions of fission products to the targets activity and partial activities of main long-lived fission products tomore » the targets activity and partial activities of main long-lived fission products were evaluated. The accumulation of Po isotopes due to reactions induced by secondary alpha-particles were found to be important for the Pb target as compared with two-step radiative capture. The production of Tritium in the targets and its contribution to the total targets activity was considered in detail. It is found that total activities of both targets are close to one another.« less
Experimental study of relativistic effects in the dp breakup reaction using the WASA detector
NASA Astrophysics Data System (ADS)
Kłos, B.; Ciepał, I.; Jamróz, B.; Khatri, G.; Kistryn, S.; Kozela, A.; Magiera, A.; Parol, W.; Skwira-Chalot, I.; Stephan, E.
2014-03-01
An experiment to investigate the 1H(overrightarrow d , pp)n breakup reaction at 340 MeV, 360 MeV and 400 MeV deuteron beam energy has been performed at the Cooler Synchrotron COSY-Jülich with the WASA detector. The main goal was to study of various aspects of few-nucleon dynamics in the medium energy region, with a particular emphasis on relativistic effects and their interplay with three nucelon forces. The almost 4π geometry of the WASA detector gives an unique possibility to study the different aspects of nucleon-nucleon dynamics in the three nucleon system. The preliminary analysis of the collected data is presented.
Probing the EBL Evolution at High Redshift Using GRBs Detected with the Fermi-LAT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Desai, A.; Ajello, M.; Omodei, N.
The extragalactic background light (EBL), from ultraviolet to infrared wavelengths, is predominantly due to emission from stars, accreting black holes and reprocessed light due to Galactic dust. The EBL can be studied through the imprint it leaves, via γ–γ absorption of high-energy photons, in the spectra of distant γ-ray sources. The EBL has been probed through the search for the attenuation it produces in the spectra of BL Lacertae (BL Lac) objects and individual γ-ray bursts (GRBs). GRBs have significant advantages over blazars for the study of the EBL especially at high redshifts. Here we analyze a combined sample ofmore » 22 GRBs, detected by the Fermi Large Area Telescope between 65 MeV and 500 GeV. We report a marginal detection (at the ~2.8σ level) of the EBL attenuation in the stacked spectra of the source sample. This measurement represents a first constraint of the EBL at an effective redshift of ~1.8. Here, we combine our results with prior EBL constraints and conclude that Fermi-LAT is instrumental to constrain the UV component of the EBL. We discuss the implications on existing empirical models of EBL evolution.« less
Measurement of radiation damage of water-based liquid scintillator and liquid scintillator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bignell, L. J.; Diwan, M. V.; Hans, S.
2015-10-19
Liquid scintillating phantoms have been proposed as a means to perform real-time 3D dosimetry for proton therapy treatment plan verification. We have studied what effect radiation damage to the scintillator will have upon this application. We have performed measurements of the degradation of the light yield and optical attenuation length of liquid scintillator and water-based liquid scintillator after irradiation by 201 MeV proton beams that deposited doses of approximately 52 Gy, 300 Gy, and 800 Gy in the scintillator. Liquid scintillator and water-based liquid scintillator (composed of 5% scintillating phase) exhibit light yield reductions of 1.74 ± 0.55 % andmore » 1.31 ± 0.59 % after ≈ 800 Gy of proton dose, respectively. Some increased optical attenuation was observed in the irradiated samples, the measured reduction to the light yield is also due to damage to the scintillation light production. Based on our results and conservative estimates of the expected dose in a clinical context, a scintillating phantom used for proton therapy treatment plan verification would exhibit a systematic light yield reduction of approximately 0.1% after a year of operation.« less
Pilarczyk, Götz; Nesnidal, Ines; Gunkel, Manuel; Bach, Margund; Bestvater, Felix; Hausmann, Michael
2017-01-01
In cancer, vulnerable breast epithelium malignance tendency correlates with number and activation of ErbB receptor tyrosine kinases. In the presented work, we observe ErbB receptors activated by irradiation-induced DNA injury or neuregulin-1β application, or alternatively, attenuated by a therapeutic antibody using high resolution fluorescence localization microscopy. The gap junction turnover coinciding with ErbB receptor activation and co-transport is simultaneously recorded. DNA injury caused by 4 Gray of 6 MeV photon γ-irradiation or alternatively neuregulin-1β application mobilized ErbB receptors in a nucleograde fashion—a process attenuated by trastuzumab antibody application. This was accompanied by increased receptor density, indicating packing into transport units. Factors mobilizing ErbB receptors also mobilized plasma membrane resident gap junction channels. The time course of ErbB receptor activation and gap junction mobilization recapitulates the time course of non-homologous end-joining DNA repair. We explain our findings under terms of DNA injury-induced membrane receptor tyrosine kinase activation and retrograde trafficking. In addition, we interpret the phenomenon of retrograde co-trafficking of gap junction connexons stimulated by ErbB receptor activation. PMID:28208769
Probing the EBL Evolution at High Redshift Using GRBs Detected with the Fermi-LAT
Desai, A.; Ajello, M.; Omodei, N.; ...
2017-11-17
The extragalactic background light (EBL), from ultraviolet to infrared wavelengths, is predominantly due to emission from stars, accreting black holes and reprocessed light due to Galactic dust. The EBL can be studied through the imprint it leaves, via γ–γ absorption of high-energy photons, in the spectra of distant γ-ray sources. The EBL has been probed through the search for the attenuation it produces in the spectra of BL Lacertae (BL Lac) objects and individual γ-ray bursts (GRBs). GRBs have significant advantages over blazars for the study of the EBL especially at high redshifts. Here we analyze a combined sample ofmore » 22 GRBs, detected by the Fermi Large Area Telescope between 65 MeV and 500 GeV. We report a marginal detection (at the ~2.8σ level) of the EBL attenuation in the stacked spectra of the source sample. This measurement represents a first constraint of the EBL at an effective redshift of ~1.8. Here, we combine our results with prior EBL constraints and conclude that Fermi-LAT is instrumental to constrain the UV component of the EBL. We discuss the implications on existing empirical models of EBL evolution.« less
Kim, Jungho; Casa, D.; Said, Ayman; ...
2018-01-31
Continued improvement of the energy resolution of resonant inelastic x-ray scattering (RIXS) spectrometers is crucial for fulfilling the potential of this technique in the study of electron dynamics in materials of fundamental and technological importance. In particular, RIXS is the only alternative tool to inelastic neutron scattering capable of providing fully momentum resolved information on dynamic spin structures of magnetic materials, but is limited to systems whose magnetic excitation energy scales are comparable to the energy resolution. The state-of-the-art spherical diced crystal analyzer optics provides energy resolution as good as 25 meV but has already reached its theoretical limit. Formore » this study, we demonstrate a novel sub-10 meV RIXS spectrometer based on flat-crystal optics at the Ir-L3 absorption edge (11.215 keV) that achieves an analyzer energy resolution of 3.9 meV, very close to the theoretical value of 3.7 meV. In addition, the new spectrometer allows efficient polarization analysis without loss of energy resolution. The performance of the instrument is emonstrated using longitudinal acoustical and optical phonons in diamond, and magnon in Sr 3Ir 2O 7. The novel sub-10 meV RIXS spectrometer thus provides a window into magnetic materials with small energy scales.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Jungho; Casa, D.; Said, Ayman
Continued improvement of the energy resolution of resonant inelastic x-ray scattering (RIXS) spectrometers is crucial for fulfilling the potential of this technique in the study of electron dynamics in materials of fundamental and technological importance. In particular, RIXS is the only alternative tool to inelastic neutron scattering capable of providing fully momentum resolved information on dynamic spin structures of magnetic materials, but is limited to systems whose magnetic excitation energy scales are comparable to the energy resolution. The state-of-the-art spherical diced crystal analyzer optics provides energy resolution as good as 25 meV but has already reached its theoretical limit. Formore » this study, we demonstrate a novel sub-10 meV RIXS spectrometer based on flat-crystal optics at the Ir-L3 absorption edge (11.215 keV) that achieves an analyzer energy resolution of 3.9 meV, very close to the theoretical value of 3.7 meV. In addition, the new spectrometer allows efficient polarization analysis without loss of energy resolution. The performance of the instrument is emonstrated using longitudinal acoustical and optical phonons in diamond, and magnon in Sr 3Ir 2O 7. The novel sub-10 meV RIXS spectrometer thus provides a window into magnetic materials with small energy scales.« less
A combined analysis of the hadronic and leptonic decays of the Z 0
NASA Astrophysics Data System (ADS)
Akrawy, M. Z.; Alexander, G.; Allison, J.; Allport, P. P.; Anderson, K. J.; Armitage, J. C.; Arnison, G. T. J.; Ashton, P.; Azuelos, G.; Baines, J. T. M.; Ball, A. H.; Banks, J.; Barker, G. J.; Barlow, R. J.; Batley, J. R.; Becker, J.; Behnke, T.; Bell, K. W.; Bella, G.; Bethke, S.; Biebel, O.; Binder, U.; Bloodworth, I. J.; Bock, P.; Breuker, H.; Brown, R. M.; Brun, R.; Buijs, A.; Burckhart, H. J.; Capiluppi, P.; Carnegie, R. K.; Carter, A. A.; Carter, J. R.; Chang, C. Y.; Charlton, D. G.; Chrin, J. T. M.; Cohen, I.; Collins, W. J.; Conboy, J. E.; Couch, M.; Coupland, M.; Cuffiani, M.; Dado, S.; Dallavalle, G. M.; Deninno, M. M.; Dieckmann, A.; Dittmar, M.; Dixit, M. S.; Duchovni, E.; Duerdoth, I. P.; Dumas, D.; El Mamouni, H.; Elcombe, P. A.; Estabrooks, P. G.; Etzion, E.; Fabbri, F.; Farthouat, P.; Fischer, H. M.; Fong, D. G.; French, M. T.; Fukunaga, C.; Gandois, B.; Ganel, O.; Gary, J. W.; Gascon, J.; Geddes, N. I.; Gee, C. N. P.; Geich-Gimbel, C.; Gensler, S. W.; Gentit, F. X.; Giacomelli, G.; Gibson, V.; Gibson, W. R.; Gillies, J. D.; Goldberg, J.; Goodrick, M. J.; Gorn, W.; Granite, D.; Gross, E.; Grosse-Wiesmann, P.; Grunhaus, J.; Hagedorn, H.; Hagemann, J.; Hansroul, M.; Hargrove, C. K.; Hart, J.; Hattersley, P. M.; Hauschild, M.; Hawkes, C. M.; Heflin, E.; Hemingway, R. J.; Heuer, R. D.; Hill, J. C.; Hillier, S. J.; Ho, C.; Hobbs, J. D.; Hobson, P. R.; Hochman, D.; Holl, B.; Homer, R. J.; Hou, S. R.; Howarth, C. P.; Hughes-Jones, R. E.; Igo-Kemenes, P.; Ihssen, H.; Imrie, D. C.; Jawahery, A.; Jeffreys, P. W.; Jeremie, H.; Jimack, M.; Jobes, M.; Jones, R. W. L.; Jovanovic, P.; Karlen, D.; Kawagoe, K.; Kawamoto, T.; Kellogg, R. G.; Kennedy, B. W.; Kleinwort, C.; Klem, D. E.; Knop, G.; Kobayashi, T.; Kokott, T. P.; Köpke, L.; Kowalewski, R.; Kreutzmann, H.; Von Krogh, J.; Kroll, J.; Kuwano, M.; Kyberd, P.; Lafferty, G. D.; Lamarche, F.; Larson, W. J.; Lasota, M. M. B.; Layter, J. G.; Le Du, P.; Leblanc, P.; Lee, A. M.; Lellouch, D.; Lennert, P.; Lessard, L.; Levinson, L.; Lloyd, S. L.; Loebinger, F. K.; Lorah, J. M.; Lorazo, B.; Losty, M. J.; Ludwig, J.; Lupu, N.; Ma, J.; Macbeth, A. A.; Mannelli, M.; Marcellini, S.; Maringer, G.; Martin, A. J.; Martin, J. P.; Mashimo, T.; Mättig, P.; Maur, U.; McMahon, T. J.; McPherson, A. C.; Meijers, F.; Menszner, D.; Merritt, F. S.; Mes, H.; Michelini, A.; Middleton, R. P.; Mikenberg, G.; Miller, D. J.; Milstene, C.; Minowa, M.; Mohr, W.; Montanari, A.; Mori, T.; Moss, M. W.; Muller, A.; Murphy, P. G.; Murray, W. J.; Nellen, B.; Nguyen, H. H.; Nozaki, M.; O'Dowd, A. J. P.; O'Neale, S. W.; O'Neill, B. P.; Oakham, F. G.; Odorici, F.; Ogg, M.; Oh, H.; Oreglia, M. J.; Orito, S.; Patrick, G. N.; Pawley, S. J.; Pfister, P.; Pilcher, J. E.; Pinfold, J. L.; Plane, D. E.; Poli, B.; Pouladdej, A.; Pritchard, T. W.; Quast, G.; Raab, J.; Redmond, M. W.; Rees, D. L.; Regimbald, M.; Riles, K.; Roach, C. M.; Robins, S. A.; Rollnik, A.; Roney, J. M.; Rossberg, S.; Rossi, A. M.; Routenburg, P.; Runge, K.; Runolfsson, O.; Sanghera, S.; Sansum, R. A.; Sasaki, M.; Saunders, B. J.; Schaile, A. D.; Schaile, O.; Schappert, W.; Scharff-Hansen, P.; Von der Schmitt, H.; Schreiber, S.; Schwarz, J.; Shapira, A.; Shen, B. C.; Sherwood, P.; Simon, A.; Siroli, G. P.; Skuja, A.; Smith, A. M.; Smith, T. J.; Snow, G. A.; Spreadbury, E. J.; Springer, R. W.; Sproston, M.; Stephens, K.; Stier, H. E.; Ströhmer, R.; Strom, D.; Takeda, H.; Takeshita, T.; Tsukamoto, T.; Turner, M. F.; Tysarczyk-Niemeyer, G.; Van den Plas, D.; Vandalen, G. J.; Virtue, C. J.; Wagner, A.; Wahl, C.; Ward, C. P.; Ward, D. R.; Waterhouse, J.; Watkins, P. M.; Watson, A. T.; Watson, N. K.; Weber, M.; Weisz, S.; Wermes, N.; Weymann, M.; Wilson, G. W.; Wilson, J. A.; Wingerter, I.; Winterer, V.-H.; Wood, N. C.; Wotton, S.; Wuensch, B.; Wyatt, T. R.; Yaari, R.; Yang, Y.; Yekutieli, G.; Yoshida, T.; Zeuner, W.; Zorn, G. T.; Zylberajch, S.; OPAL Collaboration
1990-04-01
We report on a measurement of the mass of the Z 0 boson, its total width, and its partial decay widths into hadrons and leptons. On the basis of 25 801 hadronic decays and 1999 decays into electrons, muons or taus, selected over eleven energy points between 88.28 GeV and 95.04 GeV, we obtain from a combined fit to hadrons and leptons a mass of Mz=91.154±0.021 (exp)±0.030 (LEP) GeV, and a total width of Γz=2.536±0.045 GeV. The errors on Mz have been separated into the experimental error and the uncertainty due to the LEP beam energy. The measured leptonic partial widths are Γee=81.2±2.6 MeV, Γμμ=82.6± 5.8 MeV, and Γττ=85.7±7.1 MeV, consistent with lepton universality. From a fit assuming lepton universality we obtain Γℓ + ℓ - = 81.9±2.0 MeV. The hadronic partial width is Γhad=1838±46 MeV. From the measured total and partial widths a model independent value for the invisible width is calculated to be Γinv=453±44 MeV. The errors quoted include both the statistical and the systematic uncertainties.
24Na at Ex=4.7 -5.9 MeV from 22Ne(3He,p )
NASA Astrophysics Data System (ADS)
Fortune, H. T.
2018-04-01
Abstract. Analysis of data from the 22Ne(3He,p ) 24Na reaction has been extended to include 18 angular distributions for states between 4.7 and 5.9 MeV. A distorted-wave Born-approximation analysis allows the determination of ℓ value(s) for most of them. Results for Jπ are compared with previous information. In general, agreement is good. Some apparent disagreements between current and past results are indicative of population of a different state in this reaction than the nearby one listed in the compilation.
AGILE detection of gamma-ray emission from the FSRQ Ton 0599
NASA Astrophysics Data System (ADS)
Bulgarelli, A.; Parmiggiani, N.; Lucarelli, F.; Verrecchia, F.; Pittori, C.; Tavani, M.; Vercellone, S.; Colafrancesco, S.; Cardillo, M.; Piano, G.; Ursi, A.; Fioretti, V.; Pilia, M.; Donnarumma, I.; Gianotti, F.; Trifoglio, M.; Giuliani, A.; Mereghetti, S.; Caraveo, P.; Perotti, F.; Chen, A.; Argan, A.; Costa, E.; Del Monte, E.; Evangelista, Y.; Feroci, M.; Lazzarotto, F.; Lapshov, I.; Pacciani, L.; Soffitta, P.; Sabatini, S.; Vittorini, V.; Pucella, G.; Rapisarda, M.; Di Cocco, G.; Fuschino, F.; Galli, M.; Labanti, C.; Marisaldi, M.; Pellizzoni, A.; Trois, A.; Barbiellini, G.; Vallazza, E.; Longo, F.; Morselli, A.; Picozza, P.; Prest, M.; Lipari, P.; Zanello, D.; Cattaneo, P. W.; Rappoldi, A.; Ferrari, A.; Paoletti, F.; Antonelli, A.; Giommi, P.; Salotti, L.; Valentini, G.; D'Amico, F.
2017-12-01
AGILE is detecting increasing gamma-ray emission above 100 MeV from a source positionally consistent with the FSRQ Ton 0599. Integrating from 2017-12-16 05:45 to 2017-12-18 05:45 UT, a preliminary maximum likelihood analysis yields a detection above 5 sigma and a flux F(E > 100 MeV)=(2.0 +/- 0.6) x 10^-6 ph cm^-2 s^-1.
AGILE detection of increasing gamma-ray activity from CTA 102
NASA Astrophysics Data System (ADS)
Lucarelli, F.; Verrecchia, F.; Pittori, C.; Tavani, M.; Vercellone, S.; Colafrancesco, S.; Bulgarelli, A.; Cardillo, M.; Piano, G.; Fioretti, V.; Parmiggiani, N.; Pilia, M.; Donnarumma, I.; Gianotti, F.; Trifoglio, M.; Giuliani, A.; Mereghetti, S.; Caraveo, P.; Perotti, F.; Chen, A.; Argan, A.; Costa, E.; Del Monte, E.; Evangelista, Y.; Feroci, M.; Lazzarotto, F.; Lapshov, I.; Pacciani, L.; Soffitta, P.; Sabatini, S.; Vittorini, V.; Pucella, G.; Rapisarda, M.; Di Cocco, G.; Fuschino, F.; Galli, M.; Labanti, C.; Marisaldi, M.; Pellizzoni, A.; Trois, A.; Barbiellini, G.; Vallazza, E.; Longo, F.; Morselli, A.; Picozza, P.; Prest, M.; Lipari, P.; Zanello, D.; Cattaneo, P. W.; Rappoldi, A.; Ferrari, A.; Paoletti, F.; Antonelli, A.; Giommi, P.; Salotti, L.; Valentini, G.; D'Amico, F.
2017-12-01
AGILE is detecting increasing gamma-ray emission above 100 MeV from a source positionally consistent with the FSRQ CTA 102. Integrating from 2017-12-07 06:00 UT to 2017-12-09 06:00 UT, a preliminary maximum likelihood analysis yields a detection above 6 sigma and a flux F(E > 100 MeV)=(3.6 +/- 0.9) x 10^-6 ph cm^-2 s^-1.
Nuclear reaction analysis for H, Li, Be, B, C, N, O and F with an RBS check
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lanford, W. A.; Parenti, M.; Nordell, B. J.
2015-11-12
In this paper, 15N nuclear reaction analysis (NRA) for H is combined with 1.2 MeV deuteron (D) NRA which provides a simultaneous analysis for Li, Be, B, C, N, O and F. The energy dependence of the D NRA has been measured and used to correct for the D energy loss in film being analyzed. A 2 MeV He RBS measurement is made. Film composition is determined by a self-consistent analysis of the light element NRA data combined with an RBS analysis for heavy elements. This composition is used to simulate, with no adjustable parameters, the complete RBS spectrum. Finally,more » comparison of this simulated RBS spectrum with the measured spectrum provides a powerful check of the analysis.« less
NASA Technical Reports Server (NTRS)
Fichtel, C. E.; Hartman, R. C.; Kniffen, D. A.; Thompson, D. J.; Ogelman, H. B.; Ozel, M. E.; Tumer, T.
1977-01-01
An analysis of all the second Small Astronomy Satellite (SAS-2) gamma-ray data for galactic latitudes higher than 10 deg in both hemispheres has shown that the intensity varies with galactic latitude, being larger near 10 deg than 90 deg. For energies above 100 MeV the gamma-ray data are consistent with a latitude distribution of the form I(b) = C1 + C2/sin b, with the second term being dominant. This result suggests that the radiation above 100 MeV is coming largely from local regions of the galactic disk. Between 35 and 100 MeV, a similar equation is also a good representation of the data, but here the two terms are comparable. These results indicate that the diffuse radiation above 35 MeV consists of two parts, one with a relatively hard galactic component and the other an isotropic steep spectral component which extrapolates back well to the low-energy (less than 10 MeV) diffuse radiation. The steepness of the diffuse isotropic component places significant constraints on possible theoretical models of this radiation.
Optimisation of 12 MeV electron beam simulation using variance reduction technique
NASA Astrophysics Data System (ADS)
Jayamani, J.; Termizi, N. A. S. Mohd; Kamarulzaman, F. N. Mohd; Aziz, M. Z. Abdul
2017-05-01
Monte Carlo (MC) simulation for electron beam radiotherapy consumes a long computation time. An algorithm called variance reduction technique (VRT) in MC was implemented to speed up this duration. This work focused on optimisation of VRT parameter which refers to electron range rejection and particle history. EGSnrc MC source code was used to simulate (BEAMnrc code) and validate (DOSXYZnrc code) the Siemens Primus linear accelerator model with the non-VRT parameter. The validated MC model simulation was repeated by applying VRT parameter (electron range rejection) that controlled by global electron cut-off energy 1,2 and 5 MeV using 20 × 107 particle history. 5 MeV range rejection generated the fastest MC simulation with 50% reduction in computation time compared to non-VRT simulation. Thus, 5 MeV electron range rejection utilized in particle history analysis ranged from 7.5 × 107 to 20 × 107. In this study, 5 MeV electron cut-off with 10 × 107 particle history, the simulation was four times faster than non-VRT calculation with 1% deviation. Proper understanding and use of VRT can significantly reduce MC electron beam calculation duration at the same time preserving its accuracy.
Testa, Antonella; Ballarini, Francesca; Giesen, Ulrich; Gil, Octávia Monteiro; Carante, Mario P; Tello, John; Langner, Frank; Rabus, Hans; Palma, Valentina; Pinto, Massimo; Patrono, Clarice
2018-06-01
There is a continued need for further clarification of various aspects of radiation-induced chromosomal aberration, including its correlation with radiation track structure. As part of the EMRP joint research project, Biologically Weighted Quantities in Radiotherapy (BioQuaRT), we performed experimental and theoretical analyses on chromosomal aberrations in Chinese hamster ovary cells (CHO-K1) exposed to α particles with final energies of 5.5 and 17.8 MeV (absorbed doses: ∼2.3 Gy and ∼1.9 Gy, respectively), which were generated by the microbeam at the Physikalisch-Technische Bundesanstalt (PTB) in Braunschweig, Germany. In line with the differences in linear energy transfer (approximately 85 keV/μm for 5.5 MeV and 36 keV/μm for 17.8 MeV α particles), the 5.5 MeV α particles were more effective than the 17.8 MeV α particles, both in terms of the percentage of aberrant cells (57% vs. 33%) and aberration frequency. The yield of total aberrations increased by a factor of ∼2, although the increase in dicentrics plus centric rings was less pronounced than in acentric fragments. The experimental data were compared with Monte Carlo simulations based on the BIophysical ANalysis of Cell death and chromosomal Aberrations model (BIANCA). This comparison allowed interpretation of the results in terms of critical DNA damage [cluster lesions (CLs)]. More specifically, the higher aberration yields observed for the 5.5 MeV α particles were explained by taking into account that, although the nucleus was traversed by fewer particles (nominally, 11 vs. 25), each particle was much more effective (by a factor of ∼3) at inducing CLs. This led to an increased yield of CLs per cell (by a factor of ∼1.4), consistent with the increased yield of total aberrations observed in the experiments.
NASA Astrophysics Data System (ADS)
Huerta, L.; Contreras-Valadez, R.; Palacios-Mayorga, S.; Miranda, J.; Calva-Vasquez, G.
2002-04-01
The purpose of this work was to obtain the total elemental composition of agricultural soils irrigated with well water and wastewater. The studied area is located in the Valle del Mezquital in Hidalgo State, Mexico. The studied soils were collected, every two months during one year. Particle induced X-ray emission (PIXE), Rutherford backscattering spectrometry (RBS) and nuclear reaction analysis (NRA) were applied for elemental analysis. PIXE analyses gave elemental contents of major and trace elements (Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Br, Rb, Sr, Y, Zr, and Pb). Total concentrations of Na, Mg, C, N and O were obtained by RBS and NRA. PIXE analyses were carried out with 2 MeV proton beams, RBS with 2 MeV helium ions, while NRA was applied with a 1.2 MeV deuterium beam. Results indicated that heavy metal total concentrations exceed the critical soil total concentrations according to environmental regulations.
Semimicroscopic analysis of 6Li+28Si elastic scattering at 76 to 318 MeV
NASA Astrophysics Data System (ADS)
Hassanain, M. A.; Anwar, M.; Behairy, Kassem O.
2018-04-01
Using the α-cluster structure of colliding nuclei, the elastic scattering of 6Li+28Si at energies from 76 to 318 MeV has been investigated by the use of the real folding cluster approach. The results of the cluster analysis are compared with those obtained by the CDM3Y6 effective density- and energy-dependent nucleon-nucleon (NN) interaction based upon G -matrix elements of the M3Y-Paris potential. A Woods-Saxon (WS) form was used for the imaginary potential. For all energies and derived potentials, the diffraction region was well reproduced, except at Elab=135 and 154 MeV at large angle. These results suggest that the addition of the surface (DWS) imaginary potential term to the volume imaginary potential is essential for a correct description of the refractive structure of the 6Li elastic scattering distribution at these energies. The energy dependence of the total reaction cross sections and that of the real and imaginary volume integrals is also discussed.
Nuclear physics for materials technology
NASA Astrophysics Data System (ADS)
Conlon, T. W.
1987-04-01
Although particle accelerators have traditionally been used to further our knowledge of nuclear physics, the last decade or so has seen a rapid growth of their involvement in materials technology — both to modify materials and to provide analytical information at the atomic level that cannot be obtained in other ways. The deployment of ion beams in these areas has occurred in three phases: first the exploitation of keV ion beams (in ion implantation and SIMS) then MeV light ion beams (using RBS, NRA, PIXE analysis and TLA) and currently MeV heavy ion beams, together with the associated fast recoil atoms and nuclei that they produce in interactions with materials. This trend has been accompanied by the gradual assimilation of methods such as energy analysis, microbeam focussing, particle identification, time of flight and coincidence techniques, etc., which were first developed for experimental nuclear physics use. Current examples of developments in the MeV range relevant to phases 2 and 3 are given.
NASA Technical Reports Server (NTRS)
Vanhollebeke, M. A.; Wang, J. R.; Mcdonald, F. B.
1974-01-01
This catalogue of solar cosmic ray events has been prepared for the use of solar physicists and other interested scientists. It contains some 185 solar particle events detected by the Goddard Space Flight Center Cosmic Ray Experiments on IMP's IV and V (Explorer 34 and 41) for the period May 1967 - December 1972. The data is presented in the form of hourly averages for three proton energy intervals - 0.9 - 1.6 MeV; 6 - 20 MeV and 20 - 80 MeV. In addition the time histories of .5 - 1.1 MeV electrons are shown on a separate scale. To assist in the identification of related solar events, the onset time of the electron event is indicated. The details of the instrumentation and detector techniques are described. Further descriptions of data reduction procedure and on the time-history plots are given.
Radius anomaly in the diffraction model for heavy-ion elastic scattering
NASA Astrophysics Data System (ADS)
Pandey, L. N.; Mukherjee, S. N.
1984-04-01
The elastic scattering of heavy ions, 20Ne on 208Pb, 20Ne on 235U, 84Kr on 208Pb, and 84Kr on 232Th, is examined within the framework of Frahn's diffraction model. An analysis of the experiment using the "quarter point recipe" of the expected Fresnel cross sections yields a larger radius for 208Pb than the radii for 235U and 232Th. It is shown that inclusion of the nuclear deformation in the model removes the above anomaly in the radii, and the assumption of smooth cutoff of the angular momentum simultaneously leads to a better fit to elastic scattering data, compared to those obtained by the earlier workers on the assumption of sharp cutoff. [NUCLEAR REACTIONS Elastic scattering, 20Ne+208Pb (161.2 MeV), 20Ne+235U (175 MeV), 84Kr+208Pb (500 MeV), 84Kr+232Th (500 MeV), diffraction model, nuclear deformation.
AGILE detection of enhanced gamma-ray emission from the blazar 3C 279
NASA Astrophysics Data System (ADS)
Cardillo, M.; Verrecchia, F.; Pittori, C.; Lucarelli, F.; Ursi, A.; Piano, G.; Minervini, G.; Bulgarelli, A.; Fioretti, V.; Parmiggiani, N.; Tavani, M.; Munar-Adrover, P.; Donnarumma, I.; Vercellone, S.; Striani, E.; Cardillo, M.; Gianotti, F.; Trifoglio, M.; Giuliani, A.; Mereghetti, S.; Caraveo, P.; Perotti, F.; Chen, A.; Argan, A.; Costa, E.; Del Monte, E.; Evangelista, Y.; Feroci, M.; Lazzarotto, F.; Lapshov, I.; Pacciani, L.; Soffitta, P.; Sabatini, S.; Vittorini, V.; Pucella, G.; Rapisarda, M.; Di Cocco, G.; Fuschino, F.; Galli, M.; Labanti, C.; Marisaldi, M.; Pellizzoni, A.; Pilia, M.; Trois, A.; Barbiellini, G.; Vallazza, E.; Longo, F.; Morselli, A.; Picozza, P.; Prest, M.; Lipari, P.; Zanello, D.; Cattaneo, P. W.; Rappoldi, A.; Colafrancesco, S.; Ferrari, A.; Paoletti, F.; Antonelli, A.; Giommi, P.; Salotti, L.; Valentini, G.; D'Amico, F.
2018-06-01
AGILE is detecting enhanced gamma-ray emission above 100 MeV from the blazar 3C 279. Integrating from 2018-06-03 07:56:19 UT to 2018-06-05 07:56:19 UT, a preliminary maximum likelihood analysis yields a detection at a flux F(E > 100 MeV)=(7.0 +/- 1.5) x 10^-6 ph cm^-2 s^-1 and a significance greater than 7 sigma.
A serach for moderate- and high-energy neturino emission correlated with gamma-ray bursts
NASA Technical Reports Server (NTRS)
Becker-Szendy, R.; Bratton, C. B.; Breault, J.; Casper, D.; Dye, S. T.; Gajewski, W.; Goldhaber, M.; Haines, T. J.; Halverson, P. G.; Kielczewska, D.
1995-01-01
A temporal correlation analysis between moderate- (60 Mev less than or equal to E(sub nu)greater than or equal to 2500 MeV) and high-energy (E(sub nu) greater than or equal to 2000 MeV) neutrino interactions consist of two types: the moderate-energy interactions that are contained within the volume of IMB-3 and the upward-going muons produced by high-energy nu(sub mu) interactions in the rock around the detector. No evidence is found for moderate- or high-energy neutrino emission from GRBs nor for any neutrino/neutrino correlation. The nonobservation of nu/GRB correlations allows upper limits to be placed on the neutrino flux associated with GRBs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Albertus, C.; Nieves, J.; Hernandez, E.
We present results for the strong widths corresponding to the {sigma}{sub c}{yields}{lambda}{sub c}{pi}, {sigma}{sub c}*{yields}{lambda}{sub c}{pi} and {xi}{sub c}*{yields}{xi}{sub c}{pi} decays. The calculations have been done in a nonrelativistic constituent quark model with wave functions that take advantage of the constraints imposed by heavy quark symmetry. Partial conservation of axial current hypothesis allows us to determine the strong vertices from an analysis of the axial current matrix elements. Our results {gamma}({sigma}{sub c}{sup ++}{yields}{lambda}{sub c}{sup +}{pi}{sup +})=2.41{+-}0.07{+-}0.02 MeV, {gamma}({sigma}{sub c}{sup +}{yields}{lambda}{sub c}{sup +}{pi}{sup 0})=2.79{+-}0.08{+-}0.02 MeV, {gamma}({sigma}{sub c}{sup 0}{yields}{lambda}{sub c}{sup +}{pi}{sup -})=2.37{+-}0.07{+-}0.02 MeV, {gamma}({sigma}{sub c}*{sup ++}{yields}{lambda}{sub c}{sup +}{pi}{sup +})=17.52{+-}0.74{+-}0.12 MeV, {gamma}({sigma}{sub c}*{supmore » +}{yields}{lambda}{sub c}{sup +}{pi}{sup 0})=17.31{+-}0.73{+-}0.12 MeV, {gamma}({sigma}{sub c}*{sup 0}{yields}{lambda}{sub c}{sup +}{pi}{sup -})=16.90{+-}0.71{+-}0.12 MeV, {gamma}({xi}{sub c}*{sup +}{yields}{xi}{sub c}{sup 0}{pi}{sup +}+{xi}{sub c}{sup +}{pi}{sup 0})=3.18{+-}0.10{+-}0.01 MeV, and {gamma}({xi}{sub c}*{sup 0}{yields}{xi}{sub c}{sup +}{pi}{sup -}+{xi}{sub c}{sup 0}{pi}{sup 0})=3.03{+-}0.10{+-}0.01 MeV are in good agreement with experimental determinations.« less
FLARE VERSUS SHOCK ACCELERATION OF HIGH-ENERGY PROTONS IN SOLAR ENERGETIC PARTICLE EVENTS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cliver, E. W.
2016-12-01
Recent studies have presented evidence for a significant to dominant role for a flare-resident acceleration process for high-energy protons in large (“gradual”) solar energetic particle (SEP) events, contrary to the more generally held view that such protons are primarily accelerated at shock waves driven by coronal mass ejections (CMEs). The new support for this flare-centric view is provided by correlations between the sizes of X-ray and/or microwave bursts and associated SEP events. For one such study that considered >100 MeV proton events, we present evidence based on CME speeds and widths, shock associations, and electron-to-proton ratios that indicates that eventsmore » omitted from that investigation’s analysis should have been included. Inclusion of these outlying events reverses the study’s qualitative result and supports shock acceleration of >100 MeV protons. Examination of the ratios of 0.5 MeV electron intensities to >100 MeV proton intensities for the Grechnev et al. event sample provides additional support for shock acceleration of high-energy protons. Simply scaling up a classic “impulsive” SEP event to produce a large >100 MeV proton event implies the existence of prompt 0.5 MeV electron events that are approximately two orders of magnitude larger than are observed. While classic “impulsive” SEP events attributed to flares have high electron-to-proton ratios (≳5 × 10{sup 5}) due to a near absence of >100 MeV protons, large poorly connected (≥W120) gradual SEP events, attributed to widespread shock acceleration, have electron-to-proton ratios of ∼2 × 10{sup 3}, similar to those of comparably sized well-connected (W20–W90) SEP events.« less
Flare vs. Shock Acceleration of High-energy Protons in Solar Energetic Particle Events
NASA Astrophysics Data System (ADS)
Cliver, E. W.
2016-12-01
Recent studies have presented evidence for a significant to dominant role for a flare-resident acceleration process for high-energy protons in large (“gradual”) solar energetic particle (SEP) events, contrary to the more generally held view that such protons are primarily accelerated at shock waves driven by coronal mass ejections (CMEs). The new support for this flare-centric view is provided by correlations between the sizes of X-ray and/or microwave bursts and associated SEP events. For one such study that considered >100 MeV proton events, we present evidence based on CME speeds and widths, shock associations, and electron-to-proton ratios that indicates that events omitted from that investigation’s analysis should have been included. Inclusion of these outlying events reverses the study’s qualitative result and supports shock acceleration of >100 MeV protons. Examination of the ratios of 0.5 MeV electron intensities to >100 MeV proton intensities for the Grechnev et al. event sample provides additional support for shock acceleration of high-energy protons. Simply scaling up a classic “impulsive” SEP event to produce a large >100 MeV proton event implies the existence of prompt 0.5 MeV electron events that are approximately two orders of magnitude larger than are observed. While classic “impulsive” SEP events attributed to flares have high electron-to-proton ratios (≳5 × 105) due to a near absence of >100 MeV protons, large poorly connected (≥W120) gradual SEP events, attributed to widespread shock acceleration, have electron-to-proton ratios of ˜2 × 103, similar to those of comparably sized well-connected (W20-W90) SEP events.
2012-03-01
EMPIRICAL ANALYSIS OF OPTICAL ATTENUATOR PERFORMANCE IN QUANTUM KEY DISTRIBUTION SYSTEMS USING A...DISTRIBUTION IS UNLIMITED AFIT/GCS/ENG/12-01 EMPIRICAL ANALYSIS OF OPTICAL ATTENUATOR PERFORMANCE IN QUANTUM KEY DISTRIBUTION SYSTEMS USING ...challenging as the complexity of actual implementation specifics are considered. Two components common to most quantum key distribution
Radiological properties of plastics and TLD materials its application in radiation dosimetry
NASA Astrophysics Data System (ADS)
Jabaseelan Samuel, E. James; Srinivasan, K.; Poopathi, V.
2017-05-01
In the current study, we evaluated the tissue equivalency of nine different commonly used thermoluminescence compounds and six plastic materials over the photon energy range of 15 KeV to 20 MeV. Our result confirmed that the ratio of number of electrons per gram, electron density of the entire TLD compounds and plastic materials to ICRU-44 soft tissue was lesser than unity, except in the case of polypropylene plastics. The effective atomic number ratio of all the plastic materials was also <1 excluding Poly-vinyl-chloride, and for TLD lithium borate material, it was <1 others which showed the deviation with respect to photon energy. Mass attenuation coefficient (µ/ϼ), mass absorption coefficient (µen/ρ) was calculated and the results are discussed in this paper.
Surface damage studies of ETFE polymer bombarded with low energy Si ions (⩽100 keV)
NASA Astrophysics Data System (ADS)
Minamisawa, Renato Amaral; Almeida, Adelaide De; Budak, Satilmis; Abidzina, Volha; Ila, Daryush
2007-08-01
Surface studies of ethylenetetrafluoroethylene (ETFE), bombarded with Si in a high-energy tandem Pelletron accelerator, have recently been reported. Si ion bombardment with a few MeV to a few hundred keV energies was shown to be sufficient to produce damage on ETFE film. We report here the use of a low energy implanter with Si ion energies lower than 100 keV, to induce changes on ETFE films. In order to determine the radiation damage, ETFE bombarded films were simulated with SRIM software and analyzed with optical absorption photometry (OAP), Raman and Fourier transform infrared-attenuated total reflectance (FTIR-ATR) spectroscopy to show quantitatively the physical and chemical property changes. Carbonization occurs following higher dose implantation, and hydroperoxides were formed following dehydroflorination of the polymer.
Radiation fields from neutron generators shielded with different materials
NASA Astrophysics Data System (ADS)
Chichester, D. L.; Blackburn, B. W.
2007-08-01
As a general guide for assessing radiological conditions around a DT neutron generator numerical modeling has been performed to assess neutron and photon dose profiles for a variety of shield materials ranging from 1 to 100 cm thick. In agreement with accepted radiation safety practices high-Z materials such as bismuth and lead have been found to be ineffective biological shield materials, owing in part to the existence of (n,2n) reaction channels available with 14.1 MeV DT neutrons, while low-Z materials serve as effective shields for these sources. Composite materials such as a mixture of polyethylene and bismuth, or regular concrete, are ideal shield materials for neutron generator radiation because of their ability to attenuate internally generated photon radiation resulting from neutron scattering and capture within the shields themselves.
Measurement of differential cross section of D(3He,p)4He from 0.8 MeV to 3.6 MeV
NASA Astrophysics Data System (ADS)
Zhu, J. P.; Xiao, X.; Yan, S.; Gao, Y.; Xue, J. M.; Wang, Y. G.
2017-12-01
Precise knowledge of the nuclear reaction cross-section is crucial for nuclear reaction analysis methods and its applications. In order to apply nuclear reaction analysis methods to Plasma Facing Materials studies on 4.5 MV electrostatic accelerator at Peking University, differential cross-section for d(3He,p) α at several backward angles was measured with a relative error about ± 6.2 % , gives detailed information at the laboratory angle of 135° from 800 keV to 3600 keV, as well as a rough angular distribution from 130° to 160°.
Extreme relativistic electron fluxes at geosynchronous orbit: Analysis of GOES E > 2 MeV electrons
NASA Astrophysics Data System (ADS)
Meredith, Nigel P.; Horne, Richard B.; Isles, John D.; Rodriguez, Juan V.
2015-03-01
Relativistic electrons (E > 1 MeV) cause internal charging on satellites and are an important space weather hazard. A key requirement in space weather research concerns extreme events and knowledge of the largest flux expected to be encountered over the lifetime of a satellite mission. This is interesting both from scientific and practical points of view since satellite operators, engineers, and the insurance industry need this information to better evaluate the effects of extreme events on their spacecraft. Here we conduct an extreme value analysis of daily averaged E > 2 MeV electron fluxes from the Geostationary Operational Environmental Satellites (GOES) during the 19.5 year period from 1 January 1995 to 30 June 2014. We find that the daily averaged flux measured at GOES West is typically a factor of about 2.5 higher than that measured at GOES East, and we conduct independent analyses for these two locations. The 1 in 10, 1 in 50, and 1 in 100 year daily averaged E > 2 MeV electron fluxes at GOES West are 1.84 ×105, 5.00 ×105, and 7.68 ×105 cm-2 s-1 sr-1, respectively. The corresponding fluxes at GOES East are 6.53 ×104, 1.98 ×105, and 3.25 ×105 cm-2 s-1 sr-1, respectively. The largest fluxes seen during the 19.5 year period on 29 July 2004 were particularly extreme and were seen by satellites at GOES West and GOES East. The extreme value analysis suggests that this event was a 1 in 50 year event.
NASA Astrophysics Data System (ADS)
Febbraro, M.; Becchetti, F. D.; Torres-Isea, R. O.; Riggins, J.; Lawrence, C. C.; Kolata, J. J.; Howard, A. M.
2017-08-01
The (d ,n ) reaction has been studied with targets of 9Be, 11B, 13C, N,1514, and 19F at Ed=16 MeV using a deuterated liquid-scintillator array. Advanced spectral unfolding techniques with accurately measured scintillator response functions were employed to extract neutron energy spectra without the need for long-path neutron time-of-flight. An analysis of the proton-transfer data at forward angles to the ground states of the final nuclei, using finite-range distorted-wave Born approximation analysis with common bound-state, global, and local optical-model parameter sets, yields a set of self-consistent spectroscopic factors. These are compared with the results of several previous time-of-flight measurements, most done many years ago for individual nuclei at lower energy and often analyzed using zero-range transfer codes. In contrast to some of the earlier published data, our data generally compare well with simple shell-model predictions, with little evidence for uniform quenching (reduction from shell-model values) that has previously been reported from analysis of nucleon knock-out reactions. Data for low-lying excited states in 14N from 13C(d ,n ) also is analyzed and spectroscopic information relevant to nuclear astrophysics obtained. A preliminary study of the radioactive ion beam induced reaction 7Be(d ,n ) , E (7Be)=30 MeV was carried out and indicates further improvements are needed for such measurements, which require detection of neutrons with En<2 MeV .
DOE Office of Scientific and Technical Information (OSTI.GOV)
Budzanowski, A.; Dabrowski, H.; Freindl, L.
1978-03-01
The differential cross sections for ..cap alpha.. particles elastically and inelastically scattered from /sup 5/8Ni (at 29, 34, 38, and 58 MeV) and elastically scattered from /sup 6/0Ni (at 29 and 34 MeV), are measured together with excitation functions in the 25--38 MeV region at 178.5/sup 0/ lab. These data together with the data of 26.5, 32.3, 104, and 139 MEV for /sup 5/8Ni and 32.3 and 104 MeV for /sup 6/0Ni from other sources were analyzed using an optical model with volume and surface absorptions and the Saxon-Woods square form factors. The analysis yielded energy dependent depths of bothmore » real and imaginary parts of the potential and constant geometric parameters. The analytical expressions for depths of the real and both absorption potentials are obtained. The coupled channel calculations using the above optical potential were performed for the first excited state of /sup 5/8Ni. Both elastic scattering data and coupling with the first excited state of /sup 5/8Ni are well reproduced using the above potential in the wide scattering energy range.« less
NASA Astrophysics Data System (ADS)
Abdulhay, Ibrahim Shakib
1995-01-01
The thermoluminescent dosimeter (TLD) response (integrated light output per unit exposure) of a high Z material increases more rapidly with decreasing photon energy and with energy above the pair production threshold than that of lower Z materials. The ratio of the responses obtained when two thermoluminescent dosimeter (TLD) materials are simultaneously exposed to gamma or x-rays could be used to obtain information about the incident photon energies. In addition, the responses are affected by the presence of the material surrounding the dosimeters. Two TLD's, LiF and CaSO_4, with respective effective atomic number of 8.2 and 15.3, have been chosen to be sandwiched between different absorber materials (Al, Cu, and Pb) and irradiated at selected distances from gamma radiation sources. The photon energies used in this investigation were 60 keV, 142 keV, 662 keV, 1.25 MeV, and 6.129 MeV. Fit equations of the responses of the dosimeters to different energies have been obtained and used to evaluate the energy distributions of unknown ionizing radiation fields. In addition, the electron mass attenuation coefficient beta used in Burlin and Burlin-Horowitz Cavity Theory has been modified to produce better agreement with experimental data at low photon energies and at high energies.
NASA Astrophysics Data System (ADS)
Jones, J. L.; Sterbentz, J. W.; Yoon, W. Y.; Norman, D. R.
2009-12-01
Energetic photon sources with energies greater than 6 MeV continue to be recognized as viable source for various types of inspection applications, especially those related to nuclear and/or explosive material detection. These energetic photons can be produced as a continuum of energies (i.e., bremsstrahlung) or as a set of one or more discrete photon energies (i.e., monoenergetic). This paper will provide a follow-on extension of the photon dose comparison presented at the 9th International Conference on Applications of Nuclear Techniques (June 2008). Our previous paper showed the comparative advantages and disadvantages of the photon doses provided by these two energetic interrogation sources and highlighted the higher energy advantage of the bremsstrahlung source, especially at long standoff distances (i.e., distance from source to the inspected object). This paper will pursue higher energy photon inspection advantage (up to 100 MeV) by providing dose and stimulated photonuclear interaction predictions in air and for an infinitely dilute interrogated material (used for comparative interaction rate assessments since it excludes material self-shielding) as the interrogation object positioned forward on the inspection beam axis at increasing standoff distances. In addition to the direct energetic photon-induced stimulation, the predictions will identify the importance of secondary downscattered/attenuated source-term effects arising from the photon transport in the intervening air environment.
NASA Astrophysics Data System (ADS)
Gros, P.; Amano, S.; Attié, D.; Baron, P.; Baudin, D.; Bernard, D.; Bruel, P.; Calvet, D.; Colas, P.; Daté, S.; Delbart, A.; Frotin, M.; Geerebaert, Y.; Giebels, B.; Götz, D.; Hashimoto, S.; Horan, D.; Kotaka, T.; Louzir, M.; Magniette, F.; Minamiyama, Y.; Miyamoto, S.; Ohkuma, H.; Poilleux, P.; Semeniouk, I.; Sizun, P.; Takemoto, A.; Yamaguchi, M.; Yonamine, R.; Wang, S.
2018-05-01
We presented in 2014 the very first data from a polarised gamma-ray beam between 1.7 and 74MeV. We now show the results of their analysis, and in particular the polarimetry measurements. With these results, we are establishing a new, high-performance way to do gamma-ray astronomy and, for the first time, polarimetry, in the e+e- pair regime.
NASA Astrophysics Data System (ADS)
Dankowych, John Alexander
1980-06-01
We have performed an isobar model partial wave analysis (PWA) of a high statistics sample of the reaction (pi)('-)p (,(--->)) (pi)('+)(pi)('-)(pi)('0)n at 8.45 GeV/c. We present strong evidence for the existence of the unnatural parity, isoscalar (H) and isovector (A(,1)) axial-vector mesons. The intensity distributions show significant structure while the forward phase motion relative to the isospin-2 axial-vector partial wave is consistent with that expected for Breit-Wigner resonances. The A(,1) production is mainly via M = 1, natural parity exchange while the H is produced mainly in M = 0, natural parity exchange. From a Deck model fit we obtain for the A(,1) a mass of 1241 (+OR-) 80 MeV and a width of 380 (+OR-) 100 MeV; for the H we obtain a mass of 1194 (+OR-) 55 MeV and a width of 320 (+OR-) 50 MeV. In nucleon spin flip we have evidence for an isovector, pseudoscalar resonance ((pi)') under the A(,2). The natural parity states : the (omega)(IJP = 01-), the A(,2) (IJP = 12+) and the (omega)(,g )(IJP = 03-) are strong features of the data. In the IJP = 01- partial wave thre is more cross-section than that expected for just the (omega)(783) tail.
Evaluation of Radiation Shielding Properties of the Polyvinyl Alcohol/Iron Oxide Polymer Composite
Srinivasan, K.; Samuel, E. James Jabaseelan
2017-01-01
Context: Lead is the conventional shielding material against gamma/X-rays. It has some limitations such as toxic, high density, nonflexibility, and also bremsstrahlung production during electron interaction. It may affect the accuracy of radiotherapy outcome. Aims: To theoretically analyze the radiation shielding properties of flexible polyvinyl alcohol/iron oxide polymer composite with five different concentrations of magnetite over the energy range of 15 KeV–20 MeV. Subjects and Methods: Radiological properties were calculated based on the published literature. Attenuation coefficients of pure elements are generated with the help of WinXCOM database. Results: Effective atomic numbers and electron density are increased with the concentration of magnetite. On the other hand, the number of electrons per gram decreased. Mass attenuation coefficient (μ/ϼ) and linear attenuation coefficients (μ) are higher in the lower energy <100 KeV, and their values decreased when the energy increased. Computed tomography numbers (CT) show the significant variation between the concentrations in <60 KeV. Half-value layer and tenth-value layers are directly proportional to the energy and indirectly proportional to the concentration of magnetite. Transmission curve, relaxation length (ƛ), kinetic energy released in the matter, and elemental weight fraction are also calculated and the results are discussed. Conclusions: 0.5% of the magnetite gives superior shielding properties compared with other concentrations. It may be due to the presence of 0.3617% of Fe. Elemental weight fraction, atomic number, photon energy, and mass densities are the important parameters to understand the shielding behavior of any material. PMID:29296043
Park, Eun-Ah; Goo, Jin Mo; Park, Sang Joon; Lee, Hyun Ju; Lee, Chang Hyun; Park, Chang Min; Yoo, Chul-Gyu; Kim, Jong Hyo
2010-09-01
To evaluate the potential of xenon ventilation computed tomography (CT) in the quantitative and visual analysis of chronic obstructive pulmonary disease (COPD). This study was approved by the institutional review board. After informed consent was obtained, 32 patients with COPD underwent CT performed before the administration of xenon, two-phase xenon ventilation CT with wash-in (WI) and wash-out (WO) periods, and pulmonary function testing (PFT). For quantitative analysis, results of PFT were compared with attenuation parameters from prexenon images and xenon parameters from xenon-enhanced images in the following three areas at each phase: whole lung, lung with normal attenuation, and low-attenuating lung (LAL). For visual analysis, ventilation patterns were categorized according to the pattern of xenon attenuation in the area of structural abnormalities compared with that in the normal-looking background on a per-lobe basis: pattern A consisted of isoattenuation or high attenuation in the WI period and isoattenuation in the WO period; pattern B, isoattenuation or high attenuation in the WI period and high attenuation in the WO period; pattern C, low attenuation in both the WI and WO periods; and pattern D, low attenuation in the WI period and isoattenuation or high attenuation in the WO period. Among various attenuation and xenon parameters, xenon parameters of the LAL in the WO period showed the best inverse correlation with results of PFT (P < .0001). At visual analysis, while emphysema (which affected 99 lobes) commonly showed pattern A or B, airway diseases such as obstructive bronchiolitis (n = 5) and bronchiectasis (n = 2) and areas with a mucus plug (n = 1) or centrilobular nodules (n = 5) showed pattern D or C. WI and WO xenon ventilation CT is feasible for the simultaneous regional evaluation of structural and ventilation abnormalities both quantitatively and qualitatively in patients with COPD. (c) RSNA, 2010.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fallahpoor, M; Abbasi, M; Sen, A
Purpose: Patient-specific 3-dimensional (3D) internal dosimetry in targeted radionuclide therapy is essential for efficient treatment. Two major steps to achieve reliable results are: 1) generating quantitative 3D images of radionuclide distribution and attenuation coefficients and 2) using a reliable method for dose calculation based on activity and attenuation map. In this research, internal dosimetry for 153-Samarium (153-Sm) was done by SPECT-CT images coupled GATE Monte Carlo package for internal dosimetry. Methods: A 50 years old woman with bone metastases from breast cancer was prescribed 153-Sm treatment (Gamma: 103keV and beta: 0.81MeV). A SPECT/CT scan was performed with the Siemens Simbia-Tmore » scanner. SPECT and CT images were registered using default registration software. SPECT quantification was achieved by compensating for all image degrading factors including body attenuation, Compton scattering and collimator-detector response (CDR). Triple energy window method was used to estimate and eliminate the scattered photons. Iterative ordered-subsets expectation maximization (OSEM) with correction for attenuation and distance-dependent CDR was used for image reconstruction. Bilinear energy mapping is used to convert Hounsfield units in CT image to attenuation map. Organ borders were defined by the itk-SNAP toolkit segmentation on CT image. GATE was then used for internal dose calculation. The Specific Absorbed Fractions (SAFs) and S-values were reported as MIRD schema. Results: The results showed that the largest SAFs and S-values are in osseous organs as expected. S-value for lung is the highest after spine that can be important in 153-Sm therapy. Conclusion: We presented the utility of SPECT-CT images and Monte Carlo for patient-specific dosimetry as a reliable and accurate method. It has several advantages over template-based methods or simplified dose estimation methods. With advent of high speed computers, Monte Carlo can be used for treatment planning on a day to day basis.« less
NASA Astrophysics Data System (ADS)
Kotov, Yu. D.; Arkhangelskaja, I. V.; Arkhangelsky, A. I.; Kuznetsov, S. N.; Glyanenko, A. S.; Kalmykov, P. A.; Amandzholova, D. B.; Samoylenko, V. T.; Yurov, V. N.; Pavlov, A. V.; Chervyakova, O. I.; Afonina, I. V.
The AVS-F apparatus (Russian abbreviation for Amplitude-Time Spectrometry of the Sun) is intended for the solar flares' hard X-ray and gamma-ray emission characteristic studies and for the search and detection of the gamma-ray bursts (GRB). At present over 1,100 events with duration more than 2 s without any coordinate relations to Earth Radiation Belts and South Atlantic Anomaly were separated on the results of preliminary analysis of AVS-F experiment database.About 68 % of the identified events were associated with quasistationary equatorial precipitations-15-30 % count rate increases in the low-energy gamma-band of the AVS-F apparatus over its average value obtained by approximation of these parts with polynomials discovered on some equatorial segments in the ranges of geographic latitude of 25∘ up to +30∘. Several short events with duration of 1-16 ms associated with terrestrial gamma-ray flashes were registered during the experiment. These events were detected above the powerful thunderstorm formations.Solar flares with classes stronger than M1.0 according to the GOES classification were about 7 % of the detected events. Solar flares' hard X-rays and γ-emission were mainly observed during the rise or maximum phases of the emission in the soft X-rays band according to the detectors on board the GOES series satellites data and duration of their registration is less than of the soft X-ray bands. According to the preliminary data analysis gamma-emission with energy over 10 MeV was registered during 12 % of the observed flares. The emission in the energy band E ¿ 100 keV was registered during over 60 faint solar flares (of B and C classes according to the GOES and from several ones γ-quanta with energy up to several tens of MeV were observed.Several spectral line complexes were observed in the spectra of some solar flares stronger than M1.0 in the low-energy gamma-range. Registered spectral features were corresponded to α α-lines, annihilation line, nuclear lines, and neutron capture line on1H (2.223 MeV). In the spectrum of the January 20, 2005 solar flare the feature in the range of 15-21 MeV was detected for the first time. It can be associated with lines of 15.11 MeV (12C +16O) or 20.58 MeV (from neutron radiative capture on3He), or with their combination. Also several e-dominant flares without any gamma-lines in energy spectra were identified. All detected faint solar flares were e-dominant according to the preliminary data analysis.Thin structure with characteristic timescale of 30-160 s was observed at 99 % significance level on some solar flares stronger than M1.0 temporal profiles in the low-energy gamma-band in the energy ranges corresponding to the identified spectral features or whole gamma-band energy boundaries. According to the results of the preliminary analysis during the flare of January 20, 2005, thin structure with timescale from 7 ms to 35 ms was detected at 99 % confidence level in the energy range of 0.1-20 MeV. Some thin structure with characteristic timescale 50-110 s was observed on temporal profiles of several faint events.About 3 % of the identified events were gamma-ray bursts. During some bursts high-energy gamma-emission was observed, for example Emax = 147 ± 3 MeV for GRB050525.
Mechanisms of 200 MeV electron radiation in diamond crystal in the axial orientation
NASA Astrophysics Data System (ADS)
Ganenko, V. B.; Burdeinyi, D. D.; Truten', V. I.; Shul'ga, N. F.; Fissum, K.; Brudvik, J.; Hansen, K.; Isaksson, L.; Livingston, K.; Lundin, M.; Nilsson, B.; Schroder, B.
2018-06-01
The γ -radiation by electrons with the energy of ∼ 200 MeV in a 100 μ m-thick diamond crystal has been measured at the MAX-lab experimental facility, when the electrons are incident on the crystal along the < 100 > axis. In this case, the intensity of the -radiation with the energy ∼ 1-2 MeV is approximately 16 times higher than that in amorphous matter of the same thickness. Theoretical calculations based on the quasi-classical QED approximation are in good agreement with the experimental data. The analysis of the radiation mechanisms has shown that the main contribution to the radiation intensity resulted from electrons, moving in the above-barrier regime and at small angles to the crystal axis.
Nuclear Resonance Fluorescence Measurements of High Explosives
DOE Office of Scientific and Technical Information (OSTI.GOV)
Caggiano, Joseph A.; Warren, Glen A.; Korbly, Steve
Pacific Northwest National Laboratory and Passport Systems have collaborated to perform Nuclear Resonance Fluorescence experiments using several high quality high-explosive simulant samples. These measurements were conducted to determine the feasibility of finding and characterizing high explosive material by NRF interrogation. Electron beams of 5.1, 5.3, 8, and 10 MeV were used to produce bremsstrahlung photon beams, which irradiated the samples. The gamma-ray spectra were collected using high-purity germanium detectors. Nitrogen-to-carbon ratios of the high-explosive simulants were extracted from the 5.1 and 5.3 MeV data and compare favorably with accepted values. Analysis of the 8 and 10 MeV data is inmore » progress; preliminary isotopic comparisons within the samples are consistent with the expected results.« less
Rocco, Noemi; Lovato, Alessandro; Benhar, Omar
2016-12-23
Here, the electromagnetic responses of carbon obtained from the Green's function Monte Carlo and spectral function approaches using the same dynamical input are compared in the kinematical region corresponding to momentum transfer in the range 300–570 MeV. The results of our analysis, aimed at pinning down the limits of applicability of the approximations involved in the two schemes, indicate that the factorization ansatz underlying the spectral function formalism provides remarkably accurate results down to momentum transfer as low as 300 MeV. On the other hand, it appears that at 570 MeV relativistic corrections to the electromagnetic current not included inmore » the Monte Carlo calculations may play a significant role in the transverse channel.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rocco, Noemi; Lovato, Alessandro; Benhar, Omar
Here, the electromagnetic responses of carbon obtained from the Green's function Monte Carlo and spectral function approaches using the same dynamical input are compared in the kinematical region corresponding to momentum transfer in the range 300–570 MeV. The results of our analysis, aimed at pinning down the limits of applicability of the approximations involved in the two schemes, indicate that the factorization ansatz underlying the spectral function formalism provides remarkably accurate results down to momentum transfer as low as 300 MeV. On the other hand, it appears that at 570 MeV relativistic corrections to the electromagnetic current not included inmore » the Monte Carlo calculations may play a significant role in the transverse channel.« less
Measurement of the Stopping Power of Water for Carbon Ions Using Inverted Doppler Shift Attenuation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rahm, J.M.; II. Physikalisches Institut, Universitaet Goettingen; Baek, W.Y.
2015-07-01
Carbon ion therapy has gained importance in cancer treatment due to its locally well confined dose distribution, but there is a significant lack of experimental data which is needed for dose calculations and estimation of biological damage. Since tissue is mainly comprised of water, the energy-dependent stopping power of water is the critical measure. Importantly, previous data gathered from experiments with light ions has been limited to water vapour and ice and neglected water in its liquid phase. Additionally, theoretical models regarding the stopping power cannot yet describe the complex charge transfer interactions of the projectile at velocities in themore » range of the mean velocity of the valence electrons of the traversed medium. There are also discrepancies in the amount of phase effects concerning water and water vapour cross sections. Despite its importance there exists no experimental data for the stopping power of water for carbon ions in the energy region between 1 MeV and 5 MeV. This may be due to the short track length of carbon ions which makes traditional transmission experiments unfeasible. Therefore a project was launched to measure the stopping power of liquid water for carbon ions in the vicinity of the Bragg peak which corresponds to the energy regime of the maximum stopping power. For this measurement the inverted Doppler shift attenuation method was used. This uses the gamma quanta emitted from excited carbon nuclei which are produced by means of the {sup 12}C(α,α'){sup 12}C* reaction. The recorded γ-spectra contain the information of the projectiles velocity at the time they decay to their ground state and an internal clock provided by the exponential decay law. The deceleration of the projectile is directly connected to the stopping power which can be determined with this method as a function of the projectiles kinetic energy. Further measurements have been carried out to improve the experimental method. The setup and the preliminary results of this study will be presented. (authors)« less
1987-11-15
well as oxygen and nitrogen ). Summaries of the results for these 1: materials follow. 7 0 @U Metal Oxides - Alumina and Titania0 Bombardment of alumina...the common gas employed for IAD, due to its moderate man d low price it is possible to bombard the film with other noble gasse and nitrogen to permit...profiling with "N analysis beams requires production of substantial beams of doubly ionized 1N++ in order to cover the desired 6 MeV - 10 MeV energy
Enhanced gamma-ray emission from the microquasar Cygnus X-3 detected by AGILE
NASA Astrophysics Data System (ADS)
Piano, G.; Pittori, C.; Verrecchia, F.; Tavani, M.; Bulgarelli, A.; Fioretti, V.; Zoli, A.; Munar-Adrover, P.; Lucarelli, F.; Donnarumma, I.; Vercellone, S.; Striani, E.; Cardillo, M.; Gianotti, F.; Trifoglio, M.; Giuliani, A.; Mereghetti, S.; Caraveo, P.; Perotti, F.; Chen, A.; Argan, A.; Costa, E.; Del Monte, E.; Evangelista, Y.; Feroci, M.; Lazzarotto, F.; Lapshov, I.; Pacciani, L.; Soffitta, P.; Sabatini, S.; Vittorini, V.; Pucella, G.; Rapisarda, M.; Di Cocco, G.; Fuschino, F.; Galli, M.; Labanti, C.; Marisaldi, M.; Pellizzoni, A.; Pilia, M.; Trois, A.; Barbiellini, G.; Vallazza, E.; Longo, F.; Morselli, A.; Picozza, P.; Prest, M.; Lipari, P.; Zanello, D.; Cattaneo, P. W.; Rappoldi, A.; Colafrancesco, S.; Parmiggiani, N.; Ferrari, A.; Antonelli, A.; Giommi, P.; Salotti, L.; Valentini, G.; D'Amico, F.
2016-04-01
Integrating from 2016-04-16 00:00 UT to 2016-04-19 00:00 UT, the AGILE-GRID detector is revealing gamma-ray emission above 100 MeV from a source positionally consistent with Cygnus X-3 at Galactic coordinates (l, b) = (79.4, 0.2) +/- 0.6 (stat.) +/- 0.1 (syst.) deg, with flux F( > 100 MeV) = (2.0 +/- 0.8) x 10^-6 photons/cm^2/s, as determined by a multi-source likelihood analysis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Babzien, M.; Kusche, K.; Yakimenko, V.
2011-08-09
Two compressed electron beam bunches from a single 60-MeV bunch have been generated in a reproducible manner during compression in the magnetic chicane - 'dog leg' arrangement at ATF. Measurements indicate they have comparable bunch lengths ({approx}100-200 fs) and are separated in energy by {approx}1.8 MeV with the higher-energy bunch preceding the lower-energy bunch by 0.5-1 ps. Some simulation results for analyzing the double-bunch formation process are also presented.
New interplanetary proton fluence model
NASA Technical Reports Server (NTRS)
Feynman, Joan; Armstrong, T. P.; Dao-Gibner, L.; Silverman, S.
1990-01-01
A new predictive engineering model for the interplanetary fluence of protons with above 10 MeV and above 30 MeV is described. The data set used is a combination of observations made from the earth's surface and from above the atmosphere between 1956 and 1963 and observations made from spacecraft in the vicinity of earth between 1963 and 1985. The data cover a time period three times as long as the period used in earlier models. With the use of this data set the distinction between 'ordinary proton events' and 'anomalously large events' made in earlier work disappears. This permitted the use of statistical analysis methods developed for 'ordinary events' on the entire data set. The greater than 10 MeV fluences at 1 AU calculated with the new model are about twice those expected on the basis of models now in use. At energies above 30 MeV, the old and new models agree. In contrast to earlier models, the results do not depend critically on the fluence from any one event and are independent of sunspot number. Mission probability curves derived from the fluence distribution are presented.
NASA Technical Reports Server (NTRS)
Fichtel, C. E.; Hartman, R. C.; Kniffen, D. A.; Thompson, D. J.; Oegelman, H. B.; Oezel, M. E.; Tuemer, T.
1977-01-01
An analysis of all of the second small astronomy satellite gamma-ray data for galactic latitudes with the absolute value of b 10 deg has shown that the intensity varies with galactic latitude, being larger near 10 deg than 90 deg. For energies above 100 MeV the gamma-ray data are consistent with a latitude distribution of the form I(b) = C sub 1 + C sub 2/sin b, with the second term being dominant. This result suggests that the radiation above 100 MeV is coming largely from local regions of the galactic disk. Between 35 and 100 MeV, a similar equation is also a good representation of the data, but here the two terms are comparable. These results indicate that the diffuse radiation above 35 MeV consists of two parts, one with a relatively hard galactic component and the other an isotropic, steep spectral component which extrapolates back well to the low energy diffuse radiation. The steepness of the diffuse isotropic component places significant constraints on possible theoretical models of this radiation.
Experimental study of the isovector giant dipole resonance in 80Zr and 81Rb
NASA Astrophysics Data System (ADS)
Ceruti, S.; Camera, F.; Bracco, A.; Mentana, A.; Avigo, R.; Benzoni, G.; Blasi, N.; Bocchi, G.; Bottoni, S.; Brambilla, S.; Crespi, F. C. L.; Giaz, A.; Leoni, S.; Million, B.; Morales, A. I.; Nicolini, R.; Pellegri, L.; Riboldi, S.; Wieland, O.; Bazzacco, D.; Ciemala, M.; Farnea, E.; Gottardo, A.; Kmiecik, M.; Maj, A.; Mengoni, D.; Michelagnoli, C.; Modamio, V.; Montanari, D.; Napoli, D.; Recchia, F.; Sahin, E.; Ur, C.; Valiente-Dobón, J. J.; Wasilewska, B.; Zieblinski, M.
2017-01-01
The isovector giant dipole resonance (IVGDR) γ decay was measured in the compound nuclei 80Zr and 81Rb at an excitation energy of E*=54 MeV. The fusion reaction 40Ca+40Ca at Ebeam=136 MeV was used to form the compound nucleus 80Zr, while the reaction 37Cl+44Ca at Ebeam=95 MeV was used to form the compound nucleus 81Rb at the same excitation energy. The IVGDR parameters extracted from the analysis were compared with the ones found at higher excitation energy (E*=83 MeV). The comparison allows one to observe two different nuclear mechanisms: (i) the IVGDR intrinsic width remains constant with the excitation energy in the nucleus 81Rb; (ii) the isospin-violating spreading width (i.e., Coulomb spreading width) remains constant with the excitation energy in the nucleus 80Zr. The experimental setup used for the γ -ray detection was composed by the AGATA demonstrator array coupled to the large-volume LaBr3:Ce detectors of the HECTOR+ array.
The Hidden Dynamics of Relativistic Electrons (0.7-1.5 MeV) in the Inner Zone and Slot Region
NASA Astrophysics Data System (ADS)
Claudepierre, S. G.; O'Brien, T. P., III; Blake, J. B.; Fennell, J. F.; Looper, M. D.; Roeder, J. L.; Clemmons, J. H.; Mazur, J. E.; Turner, D. L.; Reeves, G. D.; Spence, H. E.
2016-12-01
We present Van Allen Probes ECT/MagEIS observations of relativistic electrons (0.7-1.5 MeV) in the inner zone and slot region. We describe several approaches that are used to remove background contamination from the measurements, which in these regions is primarily due to very energetic inner zone protons. This careful analysis reveals that electrons with energies in excess of 1 MeV penetrated the slot region and into the inner zone following both the March and June 2015 geomagnetic storms. We also present evidence that electrons of these energies were present in the inner radiation belt region during earlier times in the Van Allen Probes era (e.g., in 2013). For both the March and June 2015 events, we examine pitch-angle distributions that shed light on the relevant physical processes responsible for the growth and decay of such relativistic electron enhancements in the inner zone and slot. We briefly discuss initial attempts to place an upper limit on the MeV electron flux intensity in the inner zone.
NASA Astrophysics Data System (ADS)
Sobolev, Yu. G.; Penionzhkevich, Yu. E.; Aznabaev, D.; Zemlyanaya, E. V.; Ivanov, M. P.; Kabdrakhimova, G. D.; Kabyshev, A. M.; Knyazev, A. G.; Kugler, A.; Lashmanov, N. A.; Lukyanov, K. V.; Maj, A.; Maslov, V. A.; Mendibayev, K.; Skobelev, N. K.; Slepnev, R. S.; Smirnov, V. V.; Testov, D.
2017-11-01
New experimental measurements of the total reaction cross sections for the 6He + natSi and 9Li + natSi processes in the energy range of 5 to 40 A MeV are presented. A modified transmission method based on high-efficiency detection of prompt n-γ radiation has been used in the experiment. A bump is observed for the first time in the energy dependence σR( E) at E ˜ 10-30 A MeV for the 9Li + natSi reaction, and existence of the bump in σR( E) at E ˜ 10-20 A MeV first observed in the standard transmission experiments is experimentally confirmed for the 6He + natSi reaction. Theoretical analysis of the measured 6He + natSi and 9Li + natSi reaction cross sections is performed within the microscopic double folding model. Disagreement is observed between the experimental and theoretical cross sections in the region of the bump at the energies of 10 to 20 A MeV, which requires further study.
The 13C(n,α0)10Be cross section at 14.3 MeV and 17 MeV neutron energy
NASA Astrophysics Data System (ADS)
Kavrigin, P.; Belloni, F.; Frais-Koelbl, H.; Griesmayer, E.; Plompen, A. J. M.; Schillebeeckx, P.; Weiss, C.
2017-09-01
At nuclear fusion reactors, CVD diamond detectors are considered an advantageous solution for neutron flux monitoring. For such applications the knowledge of the cross section of neutron-induced nuclear reactions on natural carbon are of high importance. Especially the (n,α0) reactions, yielding the highest energy reaction products, are of relevance as they can be clearly distinguished in the spectrum. The 13C(n,α0)10Be cross section was measured relative to 12C(n,α0)9Be at the Van de Graaff facility of EC-JRC Geel, Belgium, at 14.3 MeV and 17.0 MeV neutron energies. The measurement was performed with an sCVD (single-crystal Chemical Vapor Deposition) diamond detector, where the detector material acted simultaneously as sample and as sensor. A novel data analysis technique, based on pulse-shape discrimination, allowed an efficient reduction of background events. The results of the measurement are presented and compared to previously published values for this cross-section.
NASA Astrophysics Data System (ADS)
Khachatryan, V.; Sirunyan, A. M.; Tumasyan, A.; Adam, W.; Bergauer, T.; Dragicevic, M.; Erö, J.; Friedl, M.; Frühwirth, R.; Ghete, V. M.; Hartl, C.; Hörmann, N.; Hrubec, J.; Jeitler, M.; Kiesenhofer, W.; Knünz, V.; Krammer, M.; Krätschmer, I.; Liko, D.; Mikulec, I.; Rabady, D.; Rahbaran, B.; Rohringer, H.; Schöfbeck, R.; Strauss, J.; Treberer-Treberspurg, W.; Waltenberger, W.; Wulz, C.-E.; Mossolov, V.; Shumeiko, N.; Suarez Gonzalez, J.; Alderweireldt, S.; Bansal, S.; Cornelis, T.; De Wolf, E. A.; Janssen, X.; Knutsson, A.; Lauwers, J.; Luyckx, S.; Ochesanu, S.; Rougny, R.; Van De Klundert, M.; Van Haevermaet, H.; Van Mechelen, P.; Van Remortel, N.; Van Spilbeeck, A.; Blekman, F.; Blyweert, S.; D'Hondt, J.; Daci, N.; Heracleous, N.; Keaveney, J.; Lowette, S.; Maes, M.; Olbrechts, A.; Python, Q.; Strom, D.; Tavernier, S.; Van Doninck, W.; Van Mulders, P.; Van Onsem, G. P.; Villella, I.; Caillol, C.; Clerbaux, B.; De Lentdecker, G.; Dobur, D.; Favart, L.; Gay, A. P. R.; Grebenyuk, A.; Léonard, A.; Mohammadi, A.; Perniè, L.; Randle-conde, A.; Reis, T.; Seva, T.; Thomas, L.; Vander Velde, C.; Vanlaer, P.; Wang, J.; Zenoni, F.; Adler, V.; Beernaert, K.; Benucci, L.; Cimmino, A.; Costantini, S.; Crucy, S.; Fagot, A.; Garcia, G.; Mccartin, J.; Ocampo Rios, A. A.; Poyraz, D.; Ryckbosch, D.; Salva Diblen, S.; Sigamani, M.; Strobbe, N.; Thyssen, F.; Tytgat, M.; Yazgan, E.; Zaganidis, N.; Basegmez, S.; Beluffi, C.; Bruno, G.; Castello, R.; Caudron, A.; Ceard, L.; Da Silveira, G. G.; Delaere, C.; du Pree, T.; Favart, D.; Forthomme, L.; Giammanco, A.; Hollar, J.; Jafari, A.; Jez, P.; Komm, M.; Lemaitre, V.; Nuttens, C.; Pagano, D.; Perrini, L.; Pin, A.; Piotrzkowski, K.; Popov, A.; Quertenmont, L.; Selvaggi, M.; Vidal Marono, M.; Vizan Garcia, J. M.; Beliy, N.; Caebergs, T.; Daubie, E.; Hammad, G. H.; Aldá Júnior, W. L.; Alves, G. A.; Brito, L.; Correa Martins Junior, M.; Dos Reis Martins, T.; Molina, J.; Mora Herrera, C.; Pol, M. E.; Rebello Teles, P.; Carvalho, W.; Chinellato, J.; Custódio, A.; Da Costa, E. M.; De Jesus Damiao, D.; De Oliveira Martins, C.; Fonseca De Souza, S.; Malbouisson, H.; Matos Figueiredo, D.; Mundim, L.; Nogima, H.; Prado Da Silva, W. L.; Santaolalla, J.; Santoro, A.; Sznajder, A.; Tonelli Manganote, E. J.; Vilela Pereira, A.; Bernardes, C. A.; Dogra, S.; Fernandez Perez Tomei, T. R.; Gregores, E. M.; Mercadante, P. G.; Novaes, S. F.; Padula, Sandra S.; Aleksandrov, A.; Genchev, V.; Hadjiiska, R.; Iaydjiev, P.; Marinov, A.; Piperov, S.; Rodozov, M.; Stoykova, S.; Sultanov, G.; Vutova, M.; Dimitrov, A.; Glushkov, I.; Litov, L.; Pavlov, B.; Petkov, P.; Bian, J. G.; Chen, G. M.; Chen, H. S.; Chen, M.; Cheng, T.; Du, R.; Jiang, C. H.; Plestina, R.; Romeo, F.; Tao, J.; Wang, Z.; Asawatangtrakuldee, C.; Ban, Y.; Liu, S.; Mao, Y.; Qian, S. J.; Wang, D.; Xu, Z.; Zhang, L.; Zou, W.; Avila, C.; Cabrera, A.; Chaparro Sierra, L. F.; Florez, C.; Gomez, J. P.; Gomez Moreno, B.; Sanabria, J. C.; Godinovic, N.; Lelas, D.; Polic, D.; Puljak, I.; Antunovic, Z.; Kovac, M.; Brigljevic, V.; Kadija, K.; Luetic, J.; Mekterovic, D.; Sudic, L.; Attikis, A.; Mavromanolakis, G.; Mousa, J.; Nicolaou, C.; Ptochos, F.; Razis, P. A.; Rykaczewski, H.; Bodlak, M.; Finger, M.; Finger, M.; Assran, Y.; Ellithi Kamel, A.; Mahmoud, M. A.; Radi, A.; Kadastik, M.; Murumaa, M.; Raidal, M.; Tiko, A.; Eerola, P.; Voutilainen, M.; Härkönen, J.; Karimäki, V.; Kinnunen, R.; Kortelainen, M. J.; Lampén, T.; Lassila-Perini, K.; Lehti, S.; Lindén, T.; Luukka, P.; Mäenpää, T.; Peltola, T.; Tuominen, E.; Tuominiemi, J.; Tuovinen, E.; Wendland, L.; Talvitie, J.; Tuuva, T.; Besancon, M.; Couderc, F.; Dejardin, M.; Denegri, D.; Fabbro, B.; Faure, J. L.; Favaro, C.; Ferri, F.; Ganjour, S.; Givernaud, A.; Gras, P.; Hamel de Monchenault, G.; Jarry, P.; Locci, E.; Malcles, J.; Rander, J.; Rosowsky, A.; Titov, M.; Baffioni, S.; Beaudette, F.; Busson, P.; Chapon, E.; Charlot, C.; Dahms, T.; Dalchenko, M.; Dobrzynski, L.; Filipovic, N.; Florent, A.; Granier de Cassagnac, R.; Mastrolorenzo, L.; Miné, P.; Naranjo, I. N.; Nguyen, M.; Ochando, C.; Ortona, G.; Paganini, P.; Regnard, S.; Salerno, R.; Sauvan, J. B.; Sirois, Y.; Veelken, C.; Yilmaz, Y.; Zabi, A.; Agram, J.-L.; Andrea, J.; Aubin, A.; Bloch, D.; Brom, J.-M.; Chabert, E. C.; Collard, C.; Conte, E.; Fontaine, J.-C.; Gelé, D.; Goerlach, U.; Goetzmann, C.; Le Bihan, A.-C.; Skovpen, K.; Van Hove, P.; Gadrat, S.; Beauceron, S.; Beaupere, N.; Bernet, C.; Boudoul, G.; Bouvier, E.; Brochet, S.; Carrillo Montoya, C. A.; Chasserat, J.; Chierici, R.; Contardo, D.; Courbon, B.; Depasse, P.; El Mamouni, H.; Fan, J.; Fay, J.; Gascon, S.; Gouzevitch, M.; Ille, B.; Kurca, T.; Lethuillier, M.; Mirabito, L.; Pequegnot, A. L.; Perries, S.; Ruiz Alvarez, J. D.; Sabes, D.; Sgandurra, L.; Sordini, V.; Vander Donckt, M.; Verdier, P.; Viret, S.; Xiao, H.; Tsamalaidze, Z.; Autermann, C.; Beranek, S.; Bontenackels, M.; Edelhoff, M.; Feld, L.; Heister, A.; Klein, K.; Lipinski, M.; Ostapchuk, A.; Preuten, M.; Raupach, F.; Sammet, J.; Schael, S.; Schulte, J. F.; Weber, H.; Wittmer, B.; Zhukov, V.; Ata, M.; Brodski, M.; Dietz-Laursonn, E.; Duchardt, D.; Erdmann, M.; Fischer, R.; Güth, A.; Hebbeker, T.; Heidemann, C.; Hoepfner, K.; Klingebiel, D.; Knutzen, S.; Kreuzer, P.; Merschmeyer, M.; Meyer, A.; Millet, P.; Olschewski, M.; Padeken, K.; Papacz, P.; Reithler, H.; Schmitz, S. A.; Sonnenschein, L.; Teyssier, D.; Thüer, S.; Cherepanov, V.; Erdogan, Y.; Flügge, G.; Geenen, H.; Geisler, M.; Haj Ahmad, W.; Hoehle, F.; Kargoll, B.; Kress, T.; Kuessel, Y.; Künsken, A.; Lingemann, J.; Nowack, A.; Nugent, I. M.; Pistone, C.; Pooth, O.; Stahl, A.; Aldaya Martin, M.; Asin, I.; Bartosik, N.; Behr, J.; Behrens, U.; Bell, A. J.; Bethani, A.; Borras, K.; Burgmeier, A.; Cakir, A.; Calligaris, L.; Campbell, A.; Choudhury, S.; Costanza, F.; Diez Pardos, C.; Dolinska, G.; Dooling, S.; Dorland, T.; Eckerlin, G.; Eckstein, D.; Eichhorn, T.; Flucke, G.; Garay Garcia, J.; Geiser, A.; Gizhko, A.; Gunnellini, P.; Hauk, J.; Hempel, M.; Jung, H.; Kalogeropoulos, A.; Karacheban, O.; Kasemann, M.; Katsas, P.; Kieseler, J.; Kleinwort, C.; Korol, I.; Krücker, D.; Lange, W.; Leonard, J.; Lipka, K.; Lobanov, A.; Lohmann, W.; Lutz, B.; Mankel, R.; Marfin, I.; Melzer-Pellmann, I.-A.; Meyer, A. B.; Mittag, G.; Mnich, J.; Mussgiller, A.; Naumann-Emme, S.; Nayak, A.; Ntomari, E.; Perrey, H.; Pitzl, D.; Placakyte, R.; Raspereza, A.; Ribeiro Cipriano, P. M.; Roland, B.; Ron, E.; Sahin, M. Ö.; Salfeld-Nebgen, J.; Saxena, P.; Schoerner-Sadenius, T.; Schröder, M.; Seitz, C.; Spannagel, S.; Vargas Trevino, A. D. R.; Walsh, R.; Wissing, C.; Blobel, V.; Centis Vignali, M.; Draeger, A. R.; Erfle, J.; Garutti, E.; Goebel, K.; Görner, M.; Haller, J.; Hoffmann, M.; Höing, R. S.; Junkes, A.; Kirschenmann, H.; Klanner, R.; Kogler, R.; Lapsien, T.; Lenz, T.; Marchesini, I.; Marconi, D.; Ott, J.; Peiffer, T.; Perieanu, A.; Pietsch, N.; Poehlsen, J.; Poehlsen, T.; Rathjens, D.; Sander, C.; Schettler, H.; Schleper, P.; Schlieckau, E.; Schmidt, A.; Seidel, M.; Sola, V.; Stadie, H.; Steinbrück, G.; Troendle, D.; Usai, E.; Vanelderen, L.; Vanhoefer, A.; Barth, C.; Baus, C.; Berger, J.; Böser, C.; Butz, E.; Chwalek, T.; De Boer, W.; Descroix, A.; Dierlamm, A.; Feindt, M.; Frensch, F.; Giffels, M.; Gilbert, A.; Hartmann, F.; Hauth, T.; Husemann, U.; Katkov, I.; Kornmayer, A.; Lobelle Pardo, P.; Mozer, M. U.; Müller, T.; Müller, Th.; Nürnberg, A.; Quast, G.; Rabbertz, K.; Röcker, S.; Simonis, H. J.; Stober, F. M.; Ulrich, R.; Wagner-Kuhr, J.; Wayand, S.; Weiler, T.; Wolf, R.; Anagnostou, G.; Daskalakis, G.; Geralis, T.; Giakoumopoulou, V. A.; Kyriakis, A.; Loukas, D.; Markou, A.; Markou, C.; Psallidas, A.; Topsis-Giotis, I.; Agapitos, A.; Kesisoglou, S.; Panagiotou, A.; Saoulidou, N.; Stiliaris, E.; Tziaferi, E.; Aslanoglou, X.; Evangelou, I.; Flouris, G.; Foudas, C.; Kokkas, P.; Manthos, N.; Papadopoulos, I.; Paradas, E.; Strologas, J.; Bencze, G.; Hajdu, C.; Hidas, P.; Horvath, D.; Sikler, F.; Veszpremi, V.; Vesztergombi, G.; Zsigmond, A. J.; Beni, N.; Czellar, S.; Karancsi, J.; Molnar, J.; Palinkas, J.; Szillasi, Z.; Makovec, A.; Raics, P.; Trocsanyi, Z. L.; Ujvari, B.; Swain, S. K.; Beri, S. B.; Bhatnagar, V.; Gupta, R.; Bhawandeep, U.; Kalsi, A. K.; Kaur, M.; Kumar, R.; Mittal, M.; Nishu, N.; Singh, J. B.; Kumar, Ashok; Kumar, Arun; Ahuja, S.; Bhardwaj, A.; Choudhary, B. C.; Kumar, A.; Malhotra, S.; Naimuddin, M.; Ranjan, K.; Sharma, V.; Banerjee, S.; Bhattacharya, S.; Chatterjee, K.; Dutta, S.; Gomber, B.; Jain, Sa.; Jain, Sh.; Khurana, R.; Modak, A.; Mukherjee, S.; Roy, D.; Sarkar, S.; Sharan, M.; Abdulsalam, A.; Dutta, D.; Kumar, V.; Mohanty, A. K.; Pant, L. M.; Shukla, P.; Topkar, A.; Aziz, T.; Banerjee, S.; Bhowmik, S.; Chatterjee, R. M.; Dewanjee, R. K.; Dugad, S.; Ganguly, S.; Ghosh, S.; Guchait, M.; Gurtu, A.; Kole, G.; Kumar, S.; Maity, M.; Majumder, G.; Mazumdar, K.; Mohanty, G. B.; Parida, B.; Sudhakar, K.; Wickramage, N.; Sharma, S.; Bakhshiansohi, H.; Behnamian, H.; Etesami, S. M.; Fahim, A.; Goldouzian, R.; Khakzad, M.; Mohammadi Najafabadi, M.; Naseri, M.; Paktinat Mehdiabadi, S.; Rezaei Hosseinabadi, F.; Safarzadeh, B.; Zeinali, M.; Felcini, M.; Grunewald, M.; Abbrescia, M.; Calabria, C.; Chhibra, S. S.; Colaleo, A.; Creanza, D.; Cristella, L.; De Filippis, N.; De Palma, M.; Fiore, L.; Iaselli, G.; Maggi, G.; Maggi, M.; My, S.; Nuzzo, S.; Pompili, A.; Pugliese, G.; Radogna, R.; Selvaggi, G.; Sharma, A.; Silvestris, L.; Venditti, R.; Verwilligen, P.; Abbiendi, G.; Benvenuti, A. C.; Bonacorsi, D.; Braibant-Giacomelli, S.; Brigliadori, L.; Campanini, R.; Capiluppi, P.; Castro, A.; Cavallo, F. R.; Codispoti, G.; Cuffiani, M.; Dallavalle, G. M.; Fabbri, F.; Fanfani, A.; Fasanella, D.; Giacomelli, P.; Grandi, C.; Guiducci, L.; Marcellini, S.; Masetti, G.; Montanari, A.; Navarria, F. L.; Perrotta, A.; Rossi, A. M.; Rovelli, T.; Siroli, G. P.; Tosi, N.; Travaglini, R.; Albergo, S.; Cappello, G.; Chiorboli, M.; Costa, S.; Giordano, F.; Potenza, R.; Tricomi, A.; Tuve, C.; Barbagli, G.; Ciulli, V.; Civinini, C.; D'Alessandro, R.; Focardi, E.; Gallo, E.; Gonzi, S.; Gori, V.; Lenzi, P.; Meschini, M.; Paoletti, S.; Sguazzoni, G.; Tropiano, A.; Benussi, L.; Bianco, S.; Fabbri, F.; Piccolo, D.; Ferretti, R.; Ferro, F.; Lo Vetere, M.; Robutti, E.; Tosi, S.; Dinardo, M. E.; Fiorendi, S.; Gennai, S.; Gerosa, R.; Ghezzi, A.; Govoni, P.; Lucchini, M. T.; Malvezzi, S.; Manzoni, R. A.; Martelli, A.; Marzocchi, B.; Menasce, D.; Moroni, L.; Paganoni, M.; Pedrini, D.; Ragazzi, S.; Redaelli, N.; Tabarelli de Fatis, T.; Buontempo, S.; Cavallo, N.; Di Guida, S.; Fabozzi, F.; Iorio, A. O. M.; Lista, L.; Meola, S.; Merola, M.; Paolucci, P.; Azzi, P.; Bacchetta, N.; Bisello, D.; Carlin, R.; Checchia, P.; Dall'Osso, M.; Dorigo, T.; Gasparini, F.; Gasparini, U.; Gozzelino, A.; Gulmini, M.; Kanishchev, K.; Lacaprara, S.; Margoni, M.; Meneguzzo, A. T.; Passaseo, M.; Pazzini, J.; Pozzobon, N.; Ronchese, P.; Simonetto, F.; Torassa, E.; Tosi, M.; Zotto, P.; Zucchetta, A.; Zumerle, G.; Gabusi, M.; Ratti, S. P.; Re, V.; Riccardi, C.; Salvini, P.; Vitulo, P.; Biasini, M.; Bilei, G. M.; Ciangottini, D.; Fanò, L.; Lariccia, P.; Mantovani, G.; Menichelli, M.; Saha, A.; Santocchia, A.; Spiezia, A.; Androsov, K.; Azzurri, P.; Bagliesi, G.; Bernardini, J.; Boccali, T.; Broccolo, G.; Castaldi, R.; Ciocci, M. A.; Dell'Orso, R.; Donato, S.; Fedi, G.; Fiori, F.; Foà, L.; Giassi, A.; Grippo, M. T.; Ligabue, F.; Lomtadze, T.; Martini, L.; Messineo, A.; Moon, C. S.; Palla, F.; Rizzi, A.; Savoy-Navarro, A.; Serban, A. T.; Spagnolo, P.; Squillacioti, P.; Tenchini, R.; Tonelli, G.; Venturi, A.; Verdini, P. G.; Vernieri, C.; Barone, L.; Cavallari, F.; D'imperio, G.; Del Re, D.; Diemoz, M.; Jorda, C.; Longo, E.; Margaroli, F.; Meridiani, P.; Micheli, F.; Organtini, G.; Paramatti, R.; Rahatlou, S.; Rovelli, C.; Santanastasio, F.; Soffi, L.; Traczyk, P.; Amapane, N.; Arcidiacono, R.; Argiro, S.; Arneodo, M.; Bellan, R.; Biino, C.; Cartiglia, N.; Casasso, S.; Costa, M.; Covarelli, R.; Degano, A.; Demaria, N.; Finco, L.; Mariotti, C.; Maselli, S.; Migliore, E.; Monaco, V.; Musich, M.; Obertino, M. M.; Pacher, L.; Pastrone, N.; Pelliccioni, M.; Pinna Angioni, G. L.; Potenza, A.; Romero, A.; Ruspa, M.; Sacchi, R.; Solano, A.; Staiano, A.; Tamponi, U.; Belforte, S.; Candelise, V.; Casarsa, M.; Cossutti, F.; Della Ricca, G.; Gobbo, B.; La Licata, C.; Marone, M.; Schizzi, A.; Umer, T.; Zanetti, A.; Chang, S.; Kropivnitskaya, A.; Nam, S. K.; Kim, D. H.; Kim, G. N.; Kim, M. S.; Kong, D. J.; Lee, S.; Oh, Y. D.; Park, H.; Sakharov, A.; Son, D. C.; Kim, T. J.; Ryu, M. S.; Kim, J. Y.; Moon, D. H.; Song, S.; Choi, S.; Gyun, D.; Hong, B.; Jo, M.; Kim, H.; Kim, Y.; Lee, B.; Lee, K. S.; Park, S. K.; Roh, Y.; Yoo, H. D.; Choi, M.; Kim, J. H.; Park, I. C.; Ryu, G.; Choi, Y.; Choi, Y. K.; Goh, J.; Kim, D.; Kwon, E.; Lee, J.; Yu, I.; Juodagalvis, A.; Komaragiri, J. R.; Md Ali, M. A. B.; Wan Abdullah, W. A. T.; Casimiro Linares, E.; Castilla-Valdez, H.; De La Cruz-Burelo, E.; Heredia-de La Cruz, I.; Hernandez-Almada, A.; Lopez-Fernandez, R.; Sanchez-Hernandez, A.; Carrillo Moreno, S.; Vazquez Valencia, F.; Pedraza, I.; Salazar Ibarguen, H. A.; Morelos Pineda, A.; Krofcheck, D.; Butler, P. H.; Reucroft, S.; Ahmad, A.; Ahmad, M.; Hassan, Q.; Hoorani, H. R.; Khan, W. A.; Khurshid, T.; Shoaib, M.; Bialkowska, H.; Bluj, M.; Boimska, B.; Frueboes, T.; Górski, M.; Kazana, M.; Nawrocki, K.; Romanowska-Rybinska, K.; Szleper, M.; Zalewski, P.; Brona, G.; Bunkowski, K.; Cwiok, M.; Dominik, W.; Doroba, K.; Kalinowski, A.; Konecki, M.; Krolikowski, J.; Misiura, M.; Olszewski, M.; Bargassa, P.; Beirão Da Cruz E Silva, C.; Faccioli, P.; Ferreira Parracho, P. G.; Gallinaro, M.; Lloret Iglesias, L.; Nguyen, F.; Rodrigues Antunes, J.; Seixas, J.; Varela, J.; Vischia, P.; Gavrilenko, M.; Golutvin, I.; Kamenev, A.; Karjavin, V.; Konoplyanikov, V.; Korenkov, V.; Kozlov, G.; Lanev, A.; Malakhov, A.; Matveev, V.; Mitsyn, V. V.; Moisenz, P.; Palichik, V.; Perelygin, V.; Shmatov, S.; Smirnov, V.; Tikhonenko, E.; Zarubin, A.; Golovtsov, V.; Ivanov, Y.; Kim, V.; Kuznetsova, E.; Levchenko, P.; Murzin, V.; Oreshkin, V.; Smirnov, I.; Sulimov, V.; Uvarov, L.; Vavilov, S.; Vorobyev, A.; Vorobyev, An.; Andreev, Yu.; Dermenev, A.; Gninenko, S.; Golubev, N.; Kirsanov, M.; Krasnikov, N.; Pashenkov, A.; Tlisov, D.; Toropin, A.; Epshteyn, V.; Gavrilov, V.; Lychkovskaya, N.; Popov, V.; Pozdnyakov, I.; Safronov, G.; Semenov, S.; Spiridonov, A.; Stolin, V.; Vlasov, E.; Zhokin, A.; Andreev, V.; Azarkin, M.; Dremin, I.; Kirakosyan, M.; Leonidov, A.; Mesyats, G.; Rusakov, S. V.; Vinogradov, A.; Belyaev, A.; Boos, E.; Dubinin, M.; Dudko, L.; Ershov, A.; Gribushin, A.; Klyukhin, V.; Kodolova, O.; Lokhtin, I.; Obraztsov, S.; Petrushanko, S.; Savrin, V.; Snigirev, A.; Azhgirey, I.; Bayshev, I.; Bitioukov, S.; Kachanov, V.; Kalinin, A.; Konstantinov, D.; Krychkine, V.; Petrov, V.; Ryutin, R.; Sobol, A.; Tourtchanovitch, L.; Troshin, S.; Tyurin, N.; Uzunian, A.; Volkov, A.; Adzic, P.; Ekmedzic, M.; Milosevic, J.; Rekovic, V.; Alcaraz Maestre, J.; Battilana, C.; Calvo, E.; Cerrada, M.; Chamizo Llatas, M.; Colino, N.; De La Cruz, B.; Delgado Peris, A.; Domínguez Vázquez, D.; Escalante Del Valle, A.; Fernandez Bedoya, C.; Fernández Ramos, J. P.; Flix, J.; Fouz, M. C.; Garcia-Abia, P.; Gonzalez Lopez, O.; Goy Lopez, S.; Hernandez, J. M.; Josa, M. I.; Navarro De Martino, E.; Pérez-Calero Yzquierdo, A.; Puerta Pelayo, J.; Quintario Olmeda, A.; Redondo, I.; Romero, L.; Soares, M. S.; Albajar, C.; de Trocóniz, J. F.; Missiroli, M.; Moran, D.; Brun, H.; Cuevas, J.; Fernandez Menendez, J.; Folgueras, S.; Gonzalez Caballero, I.; Brochero Cifuentes, J. A.; Cabrillo, I. J.; Calderon, A.; Duarte Campderros, J.; Fernandez, M.; Gomez, G.; Graziano, A.; Lopez Virto, A.; Marco, J.; Marco, R.; Martinez Rivero, C.; Matorras, F.; Munoz Sanchez, F. J.; Piedra Gomez, J.; Rodrigo, T.; Rodríguez-Marrero, A. Y.; Ruiz-Jimeno, A.; Scodellaro, L.; Vila, I.; Vilar Cortabitarte, R.; Abbaneo, D.; Auffray, E.; Auzinger, G.; Bachtis, M.; Baillon, P.; Ball, A. H.; Barney, D.; Benaglia, A.; Bendavid, J.; Benhabib, L.; Benitez, J. F.; Bloch, P.; Bocci, A.; Bonato, A.; Bondu, O.; Botta, C.; Breuker, H.; Camporesi, T.; Cerminara, G.; Colafranceschi, S.; D'Alfonso, M.; d'Enterria, D.; Dabrowski, A.; David, A.; De Guio, F.; De Roeck, A.; De Visscher, S.; Di Marco, E.; Dobson, M.; Dordevic, M.; Dorney, B.; Dupont-Sagorin, N.; Elliott-Peisert, A.; Franzoni, G.; Funk, W.; Gigi, D.; Gill, K.; Giordano, D.; Girone, M.; Glege, F.; Guida, R.; Gundacker, S.; Guthoff, M.; Hammer, J.; Hansen, M.; Harris, P.; Hegeman, J.; Innocente, V.; Janot, P.; Kousouris, K.; Krajczar, K.; Lecoq, P.; Lourenço, C.; Magini, N.; Malgeri, L.; Mannelli, M.; Marrouche, J.; Masetti, L.; Meijers, F.; Mersi, S.; Meschi, E.; Moortgat, F.; Morovic, S.; Mulders, M.; Orsini, L.; Pape, L.; Perez, E.; Petrilli, A.; Petrucciani, G.; Pfeiffer, A.; Pimiä, M.; Piparo, D.; Plagge, M.; Racz, A.; Rolandi, G.; Rovere, M.; Sakulin, H.; Schäfer, C.; Schwick, C.; Sharma, A.; Siegrist, P.; Silva, P.; Simon, M.; Sphicas, P.; Spiga, D.; Steggemann, J.; Stieger, B.; Stoye, M.; Takahashi, Y.; Treille, D.; Tsirou, A.; Veres, G. I.; Wardle, N.; Wöhri, H. K.; Wollny, H.; Zeuner, W. D.; Bertl, W.; Deiters, K.; Erdmann, W.; Horisberger, R.; Ingram, Q.; Kaestli, H. C.; Kotlinski, D.; Langenegger, U.; Renker, D.; Rohe, T.; Bachmair, F.; Bäni, L.; Bianchini, L.; Buchmann, M. A.; Casal, B.; Chanon, N.; Dissertori, G.; Dittmar, M.; Donegà, M.; Dünser, M.; Eller, P.; Grab, C.; Hits, D.; Hoss, J.; Kasieczka, G.; Lustermann, W.; Mangano, B.; Marini, A. C.; Marionneau, M.; Martinez Ruiz del Arbol, P.; Masciovecchio, M.; Meister, D.; Mohr, N.; Musella, P.; Nägeli, C.; Nessi-Tedaldi, F.; Pandolfi, F.; Pauss, F.; Perrozzi, L.; Peruzzi, M.; Quittnat, M.; Rebane, L.; Rossini, M.; Starodumov, A.; Takahashi, M.; Theofilatos, K.; Wallny, R.; Weber, H. A.; Amsler, C.; Canelli, M. F.; Chiochia, V.; De Cosa, A.; Hinzmann, A.; Hreus, T.; Kilminster, B.; Lange, C.; Ngadiuba, J.; Pinna, D.; Robmann, P.; Ronga, F. J.; Taroni, S.; Yang, Y.; Cardaci, M.; Chen, K. H.; Ferro, C.; Kuo, C. M.; Lin, W.; Lu, Y. J.; Volpe, R.; Yu, S. S.; Chang, P.; Chang, Y. H.; Chao, Y.; Chen, K. F.; Chen, P. H.; Dietz, C.; Grundler, U.; Hou, W.-S.; Liu, Y. F.; Lu, R.-S.; Miñano Moya, M.; Petrakou, E.; Tzeng, Y. M.; Wilken, R.; Asavapibhop, B.; Singh, G.; Srimanobhas, N.; Suwonjandee, N.; Adiguzel, A.; Bakirci, M. N.; Cerci, S.; Dozen, C.; Dumanoglu, I.; Eskut, E.; Girgis, S.; Gokbulut, G.; Guler, Y.; Gurpinar, E.; Hos, I.; Kangal, E. E.; Kayis Topaksu, A.; Onengut, G.; Ozdemir, K.; Ozturk, S.; Polatoz, A.; Sunar Cerci, D.; Tali, B.; Topakli, H.; Vergili, M.; Zorbilmez, C.; Akin, I. V.; Bilin, B.; Bilmis, S.; Gamsizkan, H.; Isildak, B.; Karapinar, G.; Ocalan, K.; Sekmen, S.; Surat, U. E.; Yalvac, M.; Zeyrek, M.; Albayrak, E. A.; Gülmez, E.; Kaya, M.; Kaya, O.; Yetkin, T.; Cankocak, K.; Vardarlı, F. I.; Levchuk, L.; Sorokin, P.; Brooke, J. J.; Clement, E.; Cussans, D.; Flacher, H.; Goldstein, J.; Grimes, M.; Heath, G. P.; Heath, H. F.; Jacob, J.; Kreczko, L.; Lucas, C.; Meng, Z.; Newbold, D. M.; Paramesvaran, S.; Poll, A.; Sakuma, T.; Seif El Nasr-storey, S.; Senkin, S.; Smith, V. J.; Bell, K. W.; Belyaev, A.; Brew, C.; Brown, R. M.; Cockerill, D. J. A.; Coughlan, J. A.; Harder, K.; Harper, S.; Olaiya, E.; Petyt, D.; Shepherd-Themistocleous, C. H.; Thea, A.; Tomalin, I. R.; Williams, T.; Womersley, W. J.; Worm, S. D.; Baber, M.; Bainbridge, R.; Buchmuller, O.; Burton, D.; Colling, D.; Cripps, N.; Dauncey, P.; Davies, G.; Della Negra, M.; Dunne, P.; Elwood, A.; Ferguson, W.; Fulcher, J.; Futyan, D.; Hall, G.; Iles, G.; Jarvis, M.; Karapostoli, G.; Kenzie, M.; Lane, R.; Lucas, R.; Lyons, L.; Magnan, A.-M.; Malik, S.; Mathias, B.; Nash, J.; Nikitenko, A.; Pela, J.; Pesaresi, M.; Petridis, K.; Raymond, D. M.; Rogerson, S.; Rose, A.; Seez, C.; Sharp, P.; Tapper, A.; Vazquez Acosta, M.; Virdee, T.; Zenz, S. C.; Cole, J. E.; Hobson, P. R.; Khan, A.; Kyberd, P.; Leggat, D.; Leslie, D.; Reid, I. D.; Symonds, P.; Teodorescu, L.; Turner, M.; Dittmann, J.; Hatakeyama, K.; Kasmi, A.; Liu, H.; Pastika, N.; Scarborough, T.; Wu, Z.; Charaf, O.; Cooper, S. I.; Henderson, C.; Rumerio, P.; Avetisyan, A.; Bose, T.; Fantasia, C.; Lawson, P.; Richardson, C.; Rohlf, J.; St. John, J.; Sulak, L.; Alimena, J.; Berry, E.; Bhattacharya, S.; Christopher, G.; Cutts, D.; Demiragli, Z.; Dhingra, N.; Ferapontov, A.; Garabedian, A.; Heintz, U.; Laird, E.; Landsberg, G.; Mao, Z.; Narain, M.; Sagir, S.; Sinthuprasith, T.; Speer, T.; Swanson, J.; Breedon, R.; Breto, G.; Calderon De La Barca Sanchez, M.; Chauhan, S.; Chertok, M.; Conway, J.; Conway, R.; Cox, P. T.; Erbacher, R.; Gardner, M.; Ko, W.; Lander, R.; Mulhearn, M.; Pellett, D.; Pilot, J.; Ricci-Tam, F.; Shalhout, S.; Smith, J.; Squires, M.; Stolp, D.; Tripathi, M.; Wilbur, S.; Yohay, R.; Cousins, R.; Everaerts, P.; Farrell, C.; Hauser, J.; Ignatenko, M.; Rakness, G.; Takasugi, E.; Valuev, V.; Weber, M.; Burt, K.; Clare, R.; Ellison, J.; Gary, J. W.; Hanson, G.; Heilman, J.; Ivova Rikova, M.; Jandir, P.; Kennedy, E.; Lacroix, F.; Long, O. R.; Luthra, A.; Malberti, M.; Olmedo Negrete, M.; Shrinivas, A.; Sumowidagdo, S.; Wimpenny, S.; Branson, J. G.; Cerati, G. B.; Cittolin, S.; D'Agnolo, R. T.; Holzner, A.; Kelley, R.; Klein, D.; Letts, J.; Macneill, I.; Olivito, D.; Padhi, S.; Palmer, C.; Pieri, M.; Sani, M.; Sharma, V.; Simon, S.; Tadel, M.; Tu, Y.; Vartak, A.; Welke, C.; Würthwein, F.; Yagil, A.; Zevi Della Porta, G.; Barge, D.; Bradmiller-Feld, J.; Campagnari, C.; Danielson, T.; Dishaw, A.; Dutta, V.; Flowers, K.; Franco Sevilla, M.; Geffert, P.; George, C.; Golf, F.; Gouskos, L.; Incandela, J.; Justus, C.; Mccoll, N.; Mullin, S. D.; Richman, J.; Stuart, D.; To, W.; West, C.; Yoo, J.; Apresyan, A.; Bornheim, A.; Bunn, J.; Chen, Y.; Duarte, J.; Mott, A.; Newman, H. B.; Pena, C.; Pierini, M.; Spiropulu, M.; Vlimant, J. R.; Wilkinson, R.; Xie, S.; Zhu, R. Y.; Azzolini, V.; Calamba, A.; Carlson, B.; Ferguson, T.; Iiyama, Y.; Paulini, M.; Russ, J.; Vogel, H.; Vorobiev, I.; Cumalat, J. P.; Ford, W. T.; Gaz, A.; Krohn, M.; Luiggi Lopez, E.; Nauenberg, U.; Smith, J. G.; Stenson, K.; Wagner, S. R.; Alexander, J.; Chatterjee, A.; Chaves, J.; Chu, J.; Dittmer, S.; Eggert, N.; Mirman, N.; Nicolas Kaufman, G.; Patterson, J. R.; Ryd, A.; Salvati, E.; Skinnari, L.; Sun, W.; Teo, W. D.; Thom, J.; Thompson, J.; Tucker, J.; Weng, Y.; Winstrom, L.; Wittich, P.; Winn, D.; Abdullin, S.; Albrow, M.; Anderson, J.; Apollinari, G.; Bauerdick, L. A. T.; Beretvas, A.; Berryhill, J.; Bhat, P. C.; Bolla, G.; Burkett, K.; Butler, J. N.; Cheung, H. W. K.; Chlebana, F.; Cihangir, S.; Elvira, V. D.; Fisk, I.; Freeman, J.; Gottschalk, E.; Gray, L.; Green, D.; Grünendahl, S.; Gutsche, O.; Hanlon, J.; Hare, D.; Harris, R. M.; Hirschauer, J.; Hooberman, B.; Jindariani, S.; Johnson, M.; Joshi, U.; Klima, B.; Kreis, B.; Kwan, S.; Linacre, J.; Lincoln, D.; Lipton, R.; Liu, T.; Lopes De Sá, R.; Lykken, J.; Maeshima, K.; Marraffino, J. M.; Martinez Outschoorn, V. I.; Maruyama, S.; Mason, D.; McBride, P.; Merkel, P.; Mishra, K.; Mrenna, S.; Nahn, S.; Newman-Holmes, C.; O'Dell, V.; Prokofyev, O.; Sexton-Kennedy, E.; Soha, A.; Spalding, W. J.; Spiegel, L.; Taylor, L.; Tkaczyk, S.; Tran, N. V.; Uplegger, L.; Vaandering, E. W.; Vidal, R.; Whitbeck, A.; Whitmore, J.; Yang, F.; Acosta, D.; Avery, P.; Bortignon, P.; Bourilkov, D.; Carver, M.; Curry, D.; Das, S.; De Gruttola, M.; Di Giovanni, G. P.; Field, R. D.; Fisher, M.; Furic, I. K.; Hugon, J.; Konigsberg, J.; Korytov, A.; Kypreos, T.; Low, J. F.; Matchev, K.; Mei, H.; Milenovic, P.; Mitselmakher, G.; Muniz, L.; Rinkevicius, A.; Shchutska, L.; Snowball, M.; Sperka, D.; Yelton, J.; Zakaria, M.; Hewamanage, S.; Linn, S.; Markowitz, P.; Martinez, G.; Rodriguez, J. L.; Adams, J. R.; Adams, T.; Askew, A.; Bochenek, J.; Diamond, B.; Haas, J.; Hagopian, S.; Hagopian, V.; Johnson, K. F.; Prosper, H.; Veeraraghavan, V.; Weinberg, M.; Baarmand, M. M.; Hohlmann, M.; Kalakhety, H.; Yumiceva, F.; Adams, M. R.; Apanasevich, L.; Berry, D.; Betts, R. R.; Bucinskaite, I.; Cavanaugh, R.; Evdokimov, O.; Gauthier, L.; Gerber, C. E.; Hofman, D. J.; Kurt, P.; O'Brien, C.; Sandoval Gonzalez, I. D.; Silkworth, C.; Turner, P.; Varelas, N.; Bilki, B.; Clarida, W.; Dilsiz, K.; Haytmyradov, M.; Merlo, J.-P.; Mermerkaya, H.; Mestvirishvili, A.; Moeller, A.; Nachtman, J.; Ogul, H.; Onel, Y.; Ozok, F.; Penzo, A.; Rahmat, R.; Sen, S.; Tan, P.; Tiras, E.; Wetzel, J.; Yi, K.; Anderson, I.; Barnett, B. A.; Blumenfeld, B.; Bolognesi, S.; Fehling, D.; Gritsan, A. V.; Maksimovic, P.; Martin, C.; Swartz, M.; Xiao, M.; Baringer, P.; Bean, A.; Benelli, G.; Bruner, C.; Gray, J.; Kenny, R. P., III; Majumder, D.; Malek, M.; Murray, M.; Noonan, D.; Sanders, S.; Sekaric, J.; Stringer, R.; Wang, Q.; Wood, J. S.; Chakaberia, I.; Ivanov, A.; Kaadze, K.; Khalil, S.; Makouski, M.; Maravin, Y.; Saini, L. K.; Skhirtladze, N.; Svintradze, I.; Gronberg, J.; Lange, D.; Rebassoo, F.; Wright, D.; Baden, A.; Belloni, A.; Calvert, B.; Eno, S. C.; Gomez, J. A.; Hadley, N. J.; Jabeen, S.; Kellogg, R. G.; Kolberg, T.; Lu, Y.; Mignerey, A. C.; Pedro, K.; Skuja, A.; Tonjes, M. B.; Tonwar, S. C.; Apyan, A.; Barbieri, R.; Bierwagen, K.; Busza, W.; Cali, I. A.; Di Matteo, L.; Gomez Ceballos, G.; Goncharov, M.; Gulhan, D.; Klute, M.; Lai, Y. S.; Lee, Y.-J.; Levin, A.; Luckey, P. D.; Paus, C.; Ralph, D.; Roland, C.; Roland, G.; Stephans, G. S. F.; Sumorok, K.; Velicanu, D.; Veverka, J.; Wyslouch, B.; Yang, M.; Zanetti, M.; Zhukova, V.; Dahmes, B.; Gude, A.; Kao, S. C.; Klapoetke, K.; Kubota, Y.; Mans, J.; Nourbakhsh, S.; Rusack, R.; Singovsky, A.; Tambe, N.; Turkewitz, J.; Acosta, J. G.; Oliveros, S.; Avdeeva, E.; Bloom, K.; Bose, S.; Claes, D. R.; Dominguez, A.; Gonzalez Suarez, R.; Keller, J.; Knowlton, D.; Kravchenko, I.; Lazo-Flores, J.; Meier, F.; Ratnikov, F.; Snow, G. R.; Zvada, M.; Dolen, J.; Godshalk, A.; Iashvili, I.; Kharchilava, A.; Kumar, A.; Rappoccio, S.; Alverson, G.; Barberis, E.; Baumgartel, D.; Chasco, M.; Massironi, A.; Morse, D. M.; Nash, D.; Orimoto, T.; Trocino, D.; Wang, R.-J.; Wood, D.; Zhang, J.; Hahn, K. A.; Kubik, A.; Mucia, N.; Odell, N.; Pollack, B.; Pozdnyakov, A.; Schmitt, M.; Stoynev, S.; Sung, K.; Velasco, M.; Won, S.; Brinkerhoff, A.; Chan, K. M.; Drozdetskiy, A.; Hildreth, M.; Jessop, C.; Karmgard, D. J.; Kellams, N.; Lannon, K.; Lynch, S.; Marinelli, N.; Musienko, Y.; Pearson, T.; Planer, M.; Ruchti, R.; Smith, G.; Valls, N.; Wayne, M.; Wolf, M.; Woodard, A.; Antonelli, L.; Brinson, J.; Bylsma, B.; Durkin, L. S.; Flowers, S.; Hart, A.; Hill, C.; Hughes, R.; Kotov, K.; Ling, T. Y.; Luo, W.; Puigh, D.; Rodenburg, M.; Winer, B. L.; Wolfe, H.; Wulsin, H. W.; Driga, O.; Elmer, P.; Hardenbrook, J.; Hebda, P.; Koay, S. A.; Lujan, P.; Marlow, D.; Medvedeva, T.; Mooney, M.; Olsen, J.; Piroué, P.; Quan, X.; Saka, H.; Stickland, D.; Tully, C.; Werner, J. S.; Zuranski, A.; Brownson, E.; Malik, S.; Mendez, H.; Ramirez Vargas, J. E.; Barnes, V. E.; Benedetti, D.; Bortoletto, D.; De Mattia, M.; Gutay, L.; Hu, Z.; Jha, M. K.; Jones, M.; Jung, K.; Kress, M.; Leonardo, N.; Miller, D. H.; Neumeister, N.; Primavera, F.; Radburn-Smith, B. C.; Shi, X.; Shipsey, I.; Silvers, D.; Svyatkovskiy, A.; Wang, F.; Xie, W.; Xu, L.; Zablocki, J.; Parashar, N.; Stupak, J.; Adair, A.; Akgun, B.; Ecklund, K. M.; Geurts, F. J. M.; Li, W.; Michlin, B.; Padley, B. P.; Redjimi, R.; Roberts, J.; Zabel, J.; Betchart, B.; Bodek, A.; de Barbaro, P.; Demina, R.; Eshaq, Y.; Ferbel, T.; Galanti, M.; Garcia-Bellido, A.; Goldenzweig, P.; Han, J.; Harel, A.; Hindrichs, O.; Khukhunaishvili, A.; Korjenevski, S.; Petrillo, G.; Verzetti, M.; Vishnevskiy, D.; Ciesielski, R.; Demortier, L.; Goulianos, K.; Mesropian, C.; Arora, S.; Barker, A.; Chou, J. P.; Contreras-Campana, C.; Contreras-Campana, E.; Duggan, D.; Ferencek, D.; Gershtein, Y.; Gray, R.; Halkiadakis, E.; Hidas, D.; Kaplan, S.; Lath, A.; Panwalkar, S.; Park, M.; Salur, S.; Schnetzer, S.; Sheffield, D.; Somalwar, S.; Stone, R.; Thomas, S.; Thomassen, P.; Walker, M.; Rose, K.; Spanier, S.; York, A.; Bouhali, O.; Castaneda Hernandez, A.; Dildick, S.; Eusebi, R.; Flanagan, W.; Gilmore, J.; Kamon, T.; Khotilovich, V.; Krutelyov, V.; Montalvo, R.; Osipenkov, I.; Pakhotin, Y.; Patel, R.; Perloff, A.; Roe, J.; Rose, A.; Safonov, A.; Suarez, I.; Tatarinov, A.; Ulmer, K. A.; Akchurin, N.; Cowden, C.; Damgov, J.; Dragoiu, C.; Dudero, P. R.; Faulkner, J.; Kovitanggoon, K.; Kunori, S.; Lee, S. W.; Libeiro, T.; Volobouev, I.; Appelt, E.; Delannoy, A. G.; Greene, S.; Gurrola, A.; Johns, W.; Maguire, C.; Mao, Y.; Melo, A.; Sharma, M.; Sheldon, P.; Snook, B.; Tuo, S.; Velkovska, J.; Arenton, M. W.; Boutle, S.; Cox, B.; Francis, B.; Goodell, J.; Hirosky, R.; Ledovskoy, A.; Li, H.; Lin, C.; Neu, C.; Wolfe, E.; Wood, J.; Clarke, C.; Harr, R.; Karchin, P. E.; Kottachchi Kankanamge Don, C.; Lamichhane, P.; Sturdy, J.; Belknap, D. A.; Carlsmith, D.; Cepeda, M.; Dasu, S.; Dodd, L.; Duric, S.; Friis, E.; Hall-Wilton, R.; Herndon, M.; Hervé, A.; Klabbers, P.; Lanaro, A.; Lazaridis, C.; Levine, A.; Loveless, R.; Mohapatra, A.; Ojalvo, I.; Perry, T.; Pierro, G. A.; Polese, G.; Ross, I.; Sarangi, T.; Savin, A.; Smith, W. H.; Taylor, D.; Vuosalo, C.; Woods, N.; CMS Collaboration
2016-05-01
A measurement of the ratio of the branching fractions of the Bs0 meson to J / ψf0 (980) and to J / ψϕ (1020) is presented. The J / ψ, f0 (980), and ϕ (1020) are observed through their decays to μ+μ-, π+π-, and K+K-, respectively. The f0 and the ϕ are identified by requiring |Mπ+π- - 974 MeV | < 50 MeV and |MK+K- - 1020 MeV | < 10 MeV. The analysis is based on a data sample of pp collisions at a centre-of-mass energy of 7 TeV, collected by the CMS experiment at the LHC, corresponding to an integrated luminosity of 5.3 fb-1. The measured ratio is B(Bs0 → J / ψf0) B (f0 →π+π-)/ B (Bs0 → J / ψϕ) B (ϕ →K+K-) = 0.140 ± 0.008 (stat) ± 0.023 (syst), where the first uncertainty is statistical and the second is systematic.
Measurement of 0.511-MeV gamma rays with a balloon-borne Ge/Li/ spectrometer
NASA Technical Reports Server (NTRS)
Ling, J. C.; Mahoney, W. A.; Willett, J. B.; Jacobson, A. S.
1977-01-01
A collimated high-resolution gamma ray spectrometer was flown on a balloon over Palestine, Texas, on June 10, 1974, to obtain measurements of the terrestrial and extraterrestrial 0.511-MeV gamma rays. The spectrometer consists of four 40-cu-cm Ge(Li) crystals operating in the energy range 0.06-10 MeV; this cluster of detectors is surrounded by a CsI(Na) anticoincidence shield. This system is used primarily to allow measurements of the two escape peaks associated with high-energy gamma ray lines. It also allows a measurement of the background component of the 0.511-MeV flux produced by beta(+) decays in materials inside the CsI(Na) shield. It is shown that the measurements of the atmospheric fluxes are consistent with earlier results after allowance is made for an additional component of the background due to beta(+) decays produced by neutron- and proton-initiated interactions with materials in and near the detector. Results of the extraterrestrial flux require an extensive detailed analysis of the time-varying background because of activation buildup and balloon spatial drifts.
Astrophysical SE2 factor of the 12C(α, γ)16O reaction through the 12C(11B, 7Li)16O transfer reaction
NASA Astrophysics Data System (ADS)
Guo, B.; Du, X. C.; Li, Z. H.; Li, Y. J.; Pang, D. Y.; Su, J.; Yan, S. Q.; Fan, Q. W.; Gan, L.; Han, Z. Y.; Li, E. T.; Li, X. Y.; Lian, G.; Liu, J. C.; Pei, C. J.; Qiao, L. H.; Shen, Y. P.; Su, Y.; Wang, Y. B.; Zeng, S.; Zhou, Y.; Liu, W. P.
2016-02-01
The 12C(α, γ)16O reaction plays a key role in the evolution of stars with masses of M > 0.55 M⊙. At the Gamow peak (Ec.m. = 300 ke V, T9 = 0.2), the cross section of the 12C(α, γ)16O reaction is so small (about 10-17 barn) that the direct measurement in ground laboratory is not feasible with the existing technology. Up to now, the cross sections at lower energies can only be extrapolated from the data at higher energies. However, two subthreshold resonances, locating at Ex = 7.117 MeV and Ex = 6.917 MeV, make this extrapolation more complicated. In this work the 6.917 MeV subthreshold resonance in the 12C(α, γ)16O reaction was investigated via the 12C(11B, 7Li)16O reaction. The experiment was performed using the Q3D magnetic spectrograph at HI-13 tandem accelerator. We measured the angular distribution of the 12C(11B, 7Li)16O transfer reaction leading to the 6.917 MeV state. Based on DWBA analysis, we derived the square of ANC of the 6.917 MeV level in 16O to be (2.45± 0.28) ×1010 fm-1, with which the reduced-α width can be computed. Finally, we calculated the astrophysical SE2 factor of the 6.917 MeV resonance to be 67.6 ± 7.7 ke V b.
Upper limit on the inner radiation belt MeV electron intensity
NASA Astrophysics Data System (ADS)
Li, X.; Selesnick, R. S.; Baker, D. N.; Jaynes, A. N.; Kanekal, S. G.; Schiller, Q.; Blum, L.; Fennell, J.; Blake, J. B.
2015-02-01
No instruments in the inner radiation belt are immune from the unforgiving penetration of the highly energetic protons (tens of MeV to GeV). The inner belt proton flux level, however, is relatively stable; thus, for any given instrument, the proton contamination often leads to a certain background noise. Measurements from the Relativistic Electron and Proton Telescope integrated little experiment on board Colorado Student Space Weather Experiment CubeSat, in a low Earth orbit, clearly demonstrate that there exist sub-MeV electrons in the inner belt because their flux level is orders of magnitude higher than the background, while higher-energy electron (>1.6 MeV) measurements cannot be distinguished from the background. Detailed analysis of high-quality measurements from the Relativistic Electron and Proton Telescope on board Van Allen Probes, in a geo-transfer-like orbit, provides, for the first time, quantified upper limits on MeV electron fluxes in various energy ranges in the inner belt. These upper limits are rather different from flux levels in the AE8 and AE9 models, which were developed based on older data sources. For 1.7, 2.5, and 3.3 MeV electrons, the upper limits are about 1 order of magnitude lower than predicted model fluxes. The implication of this difference is profound in that unless there are extreme solar wind conditions, which have not happened yet since the launch of Van Allen Probes, significant enhancements of MeV electrons do not occur in the inner belt even though such enhancements are commonly seen in the outer belt.
The contribution of light Majorana neutrinos to neutrinoless double beta decay and cosmology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dell'Oro, S.; Marcocci, S.; Viel, M.
Cosmology is making impressive progress and it is producing stringent bounds on the sum of the neutrino masses Σ, a parameter of great importance for the current laboratory experiments. In this letter, we exploit the potential relevance of the analysis of Palanque-Delabrouille et al. [JCAP 02 (2015) 045] to the neutrinoless double beta decay (0ν β β) search. This analysis indicates small values for the lightest neutrino mass, since the authors find Σ < 84 meV at 1σ C.L., and provides a 1σ preference for the normal hierarchy. The allowed values for the Majorana effective mass, probed by 0ν β β, turn out to be < 75more » meV at 3σ C.L. and lower down to less than 02 meV at 1σ C.L. . If this indication is confirmed, the impact on the 0ν β β experiments will be tremendous since the possibility of detecting a signal will be out of the reach of the next generation of experiments.« less
The contribution of light Majorana neutrinos to neutrinoless double beta decay and cosmology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dell’Oro, S.; Marcocci, S.; Viel, M.
Cosmology is making impressive progress and it is producing stringent bounds on the sum of the neutrino masses Σ, a parameter of great importance for the current laboratory experiments. In this letter, we exploit the potential relevance of the analysis of Palanque-Delabrouille et al. to the neutrinoless double beta decay (0νββ) search. This analysis indicates small values for the lightest neutrino mass, since the authors find Σ<84 meV at 1σ C.L., and provides a 1σ preference for the normal hierarchy. The allowed values for the Majorana effective mass, probed by 0νββ, turn out to be <75 meV at 3σ C.L.more » and lower down to less than 20 meV at 1σ C.L. . If this indication is confirmed, the impact on the 0νββ experiments will be tremendous since the possibility of detecting a signal will be out of the reach of the next generation of experiments.« less
Experimental study of some shielding parameters for composite shields
NASA Astrophysics Data System (ADS)
Mkhaiber, Ahmed F.; Dheyaa, Abdulraheem
2018-05-01
In this study radiation protection shields have been prepared consist of composite materials have epoxy as a basis material and different reinforcing materials C Ni PbO and Bi with various reinforcing ratios 10 20 30 40 50 % and dimensions 1 × 10 × 10 cm. For examination the suitability of using this shields to protect from gamma ray some shielding parameters were calculated like: Linear attenuation coefficient μ, effective atomic number Zeffe, heaviness and half value thickness X1/2 for energy rang 1218 – 1480 KeV. These parameters have been measured by using sodium iodide system NaITI with deferent radiation sources 152Eu 60Co and 137Cs. The results show that these parameters are effected by the reinforcing ratio and gamma ray energy, it is found that the linear attenuation coefficient and atomic effective number increases with reinforcing ratio increases and decreased with energy increasing especially with high concentrations 40 50 % and at low energies Eγ < 0662 MeV with certain energy while the values of X1/2 decrease with reinforcing ratio increases. Heaviness was calculated too for all shields, with respect to lead from its values we found that this shields lighter than lead, which make it preferable to traditional material such as lead and concrete.
NASA Astrophysics Data System (ADS)
Anan'ev, A. A.; Belichenko, S. G.; Bogolyubov, E. P.; Bochkarev, O. V.; Petrov, E. V.; Polishchuk, A. M.; Udaltsov, A. Yu.
2009-12-01
Nowadays in Russia and abroad there are several groups of scientists, engaged in development of systems based on "tagged" neutron method (API method) and intended for detection of dangerous materials, including high explosives (HE). Particular attention is paid to possibility of detection of dangerous objects inside a sea cargo container. Energy gamma-spectrum, registered from object under inspection is used for determination of oxygen/carbon and nitrogen/carbon chemical ratios, according to which dangerous object is distinguished from not dangerous one. Material of filled container, however, gives rise to additional effects of rescattering and moderation of 14 MeV primary neutrons of generator, attenuation of secondary gamma-radiation from reactions of inelastic neutron scattering on objects under inspection. These effects lead to distortion of energy gamma-response from examined object and therefore prevent correct recognition of chemical ratios. These difficulties are taken into account in analytical method, presented in the paper. Method has been validated against experimental data, obtained by the system for HE detection in sea cargo, based on API method and developed in VNIIA. Influence of shielding materials on results of HE detection and identification is considered. Wood and iron were used as shielding materials. Results of method application for analysis of experimental data on HE simulator measurement (tetryl, trotyl, hexogen) are presented.
Conversion factors from counts to chemical ratios for the EURITRACK tagged neutron inspection system
NASA Astrophysics Data System (ADS)
El Kanawati, W.; Perot, B.; Carasco, C.; Eleon, C.; Valkovic, V.; Sudac, D.; Obhodas, J.
2011-10-01
The EURopean Illicit TRAfficking Countermeasures Kit (EURITRACK) uses 14 MeV neutrons produced by the 3H(d,n) 4H fusion reaction to detect explosives and narcotics in cargo containers. Reactions induced by fast neutrons produce gamma rays, which are detected in coincidence with the associated alpha particle to determine the neutron direction. In addition, the neutron path length is obtained from a time-of-flight measurement, thus allowing the origin of the gamma rays inside the container to be determined. Information concerning the chemical composition of the target material is obtained from the analysis of the energy spectrum. The carbon, oxygen, and nitrogen relative count contributions must be converted to chemical proportions to distinguish illicit and benign organic materials. An extensive set of conversion factors based on Monte Carlo numerical simulations has been calculated, taking into account neutron slowing down and photon attenuation in the cargo materials. An experimental validation of the method is presented by comparing the measured chemical fractions of known materials, in the form of bare samples or hidden in a cargo container, to their real chemical composition. Examples of application to real cargo containers are also reported, as well as simulated data with explosives and illicit drugs.
A study of neutron leakage through an Fe shield at an accelerator.
Elwyn, A J; Cossairt, J D
1986-12-01
The spectrum of neutrons, produced in the interactions of hadrons with energies up to several hundred GeV, that are emitted through a large Fe electro magnet has been determined by use of a multisphere spectrometer both before and after the shielding was augmented with concrete. The existence of leakage neutrons at energies of approximately 0.005-1.0 MeV was verified in the initial configuration, and found to be completely eliminated in the spectrum obtained after the concrete was added. The quality factor of the radiation field was measured; the values are reduced from about six to three with the extra shielding. Additional fluence measurements in the environs of the magnet can be interpreted in terms of a skyshine mechanism with source and attenuation parameters consistent with the energies and intensity of the leakage neutrons.
Triton burnup in plasma focus plasmas
NASA Astrophysics Data System (ADS)
Brzosko, Jan S.; Brzosko, Jan R., Jr.; Robouch, Benjamin V.; Ingrosso, Luigi
1995-04-01
Pure deuterium plasma discharge from plasma focus breeds 1.01 MeV tritons via the D(d,p)T fusion branch, which has the same cross section as the D(d,n)3He (En=2.45 MeV) fusion branch. Tritons are trapped in and collide with the background deuterium plasma, producing 14.1 MeV neutrons via the D(t,n)4He reaction. The paper presents published in preliminary form as well as unpublished experimental data and theoretical studies of the neutron yield ratio R=Yn(14.1 MeV)/Yn(2.45 MeV). The experimental data were obtained from 1 MJ Frascati plasma focus operated at W=490 kJ with pure deuterium plasma (in the early 1980s). Neutrons were monitored using the nuclear activation method and nuclear emulsions. The present theoretical analysis of the experimental data is based on an exact adaptation of the binary encounter theory developed by Gryzinski. It is found that the experimentally defined value 1ṡ10-3
NASA Astrophysics Data System (ADS)
Yin, Zhongli; Zhang, Shunun; Jiang, Xinzhou; Ma, Changjun; Li, Zhenkun; Hao, Jifang; Zheng, Zhihao; Liu, Zhaoyuan; Liu, Zhengmin; Ma, Shuxun; Yang, Kunshan
1989-04-01
This paper describes briefly the optimization of a PIXE setup. Three proton energies 1.5, 2.0 and 2.5 MeV and four kinds of absorbers BE (132 μm), Be (460 μm), Al (28 μm) and Be plus Mylar (460 μm+600 μm) were used. The minimum detection limits (MDL) of PIXE for these various combinations were computed and compared. PIXE analysis of Shaji was performed as an application. The result shows that the stack absorber of 460 μm Be and 600 μm Mylar films and a 2.0 MeV proton energy are most suitable for PIXE analysis of Shaji. Results of the Shaji analysis are presented. Shaji is one of the common seabuckthoms. The Shaji referred to here belongs to Hippophae rhamnoides L. Subsp. Sinensis Rousi.
NASA Astrophysics Data System (ADS)
Khan, E.; Suomijärvi, T.; Blumenfeld, Y.; Van Giai, Nguyen; Alamanos, N.; Auger, F.; Bauge, E.; Beaumel, D.; Delaroche, J. P.; Delbourgo-Salvador, P.; Drouart, A.; Fortier, S.; Frascaria, N.; Gillibert, A.; Girod, M.; Jouanne, C.; Kemper, K. W.; Lagoyannis, A.; Lapoux, V.; Lépine-Szily, A.; Lhenry, I.; Libert, J.; Maréchal, F.; Maison, J. M.; Musumarra, A.; Ottini-Hustache, S.; Piattelli, P.; Pita, S.; Pollacco, E. C.; Roussel-Chomaz, P.; Santonocito, D.; Sauvestre, J. E.; Scarpaci, J. A.; Zerguerras, T.
2001-11-01
Proton elastic and inelastic scattering angular distributions to the 2 1+ and 3 1- collective states of the proton-rich nuclei 30S and 34Ar were measured at 53 MeV/ A and 47 MeV/ A, respectively, using secondary beams from the GANIL facility and the MUST silicon strip detector array. Data for the stable 32S nucleus were also obtained at 53 MeV/ A for comparison. A phenomenological analysis was used to deduce the deformation parameters βp,p' for the low-lying collective excitations. A microscopic analysis was performed by generating matter and transition densities from self-consistent QRPA calculations. Configuration mixing calculations based on a collective Bohr Hamiltonian were also performed. DWBA and coupled-channel calculations using microscopic optical potentials built from these densities and the JLM interaction are compared to the data. There is no indication for the presence of proton skins in these nuclei. The microscopic calculations are extended to the even-even sulfur and argon isotopes from A=30 to A=40, and A=34 to A=44, respectively, and compared to available experimental results. On the basis of this analysis predictions are made for the 42,44S and 46Ar nuclei concerning ground state and transition densities.
Search for Electron Antineutrino Appearance at the Δm2˜1eV2 Scale
NASA Astrophysics Data System (ADS)
Aguilar-Arevalo, A. A.; Anderson, C. E.; Brice, S. J.; Brown, B. C.; Bugel, L.; Conrad, J. M.; Djurcic, Z.; Fleming, B. T.; Ford, R.; Garcia, F. G.; Garvey, G. T.; Gonzales, J.; Grange, J.; Green, C.; Green, J. A.; Imlay, R.; Johnson, R. A.; Karagiorgi, G.; Katori, T.; Kobilarcik, T.; Linden, S. K.; Louis, W. C.; Mahn, K. B. M.; Marsh, W.; Mauger, C.; McGary, V. T.; Metcalf, W.; Mills, G. B.; Moore, C. D.; Mousseau, J.; Nelson, R. H.; Nienaber, P.; Nowak, J. A.; Osmanov, B.; Pavlovic, Z.; Perevalov, D.; Polly, C. C.; Ray, H.; Roe, B. P.; Russell, A. D.; Shaevitz, M. H.; Sorel, M.; Spitz, J.; Stancu, I.; Stefanski, R. J.; Tayloe, R.; Tzanov, M.; van de Water, R. G.; Wascko, M. O.; White, D. H.; Wilking, M. J.; Zeller, G. P.; Zimmerman, E. D.
2009-09-01
The MiniBooNE Collaboration reports initial results from a search for ν¯μ→ν¯e oscillations. A signal-blind analysis was performed using a data sample corresponding to 3.39×1020 protons on target. The data are consistent with background prediction across the full range of neutrino energy reconstructed assuming quasielastic scattering, 200
NASA Astrophysics Data System (ADS)
Rebai, M.; Giacomelli, L.; Milocco, A.; Nocente, M.; Rigamonti, D.; Tardocchi, M.; Camera, F.; Cazzaniga, C.; Chen, Z. J.; Du, T. F.; Fan, T. S.; Giaz, A.; Hu, Z. M.; Marchi, T.; Peng, X. Y.; Gorini, G.
2016-11-01
A Single-crystal Diamond (SD) detector prototype was installed at Joint European Torus (JET) in 2013 and the achieved results have shown its spectroscopic capability of measuring 2.5 MeV neutrons from deuterium plasmas. This paper presents measurements of the SD response function to monoenergetic neutrons, which is a key point for the development of a neutron spectrometer based on SDs and compares them with Monte Carlo simulations. The analysis procedure allows for a good reconstruction of the experimental results. The good pulse height energy resolution (equivalent FWHM of 80 keV at 2.5 MeV), gain stability, insensitivity to magnetic field, and compact size make SDs attractive as compact neutron spectrometers of high flux deuterium plasmas, such as for instance those needed for the ITER neutron camera.
Analysis of nuclear resonance fluorescence excitation measured with LaBr3(Ce) detectors near 2 MeV
NASA Astrophysics Data System (ADS)
Omer, Mohamed; Negm, Hani; Ohgaki, Hideaki; Daito, Izuru; Hayakawa, Takehito; Bakr, Mahmoud; Zen, Heishun; Hori, Toshitada; Kii, Toshiteru; Masuda, Kai; Hajima, Ryoichi; Shizuma, Toshiyuki; Toyokawa, Hiroyuki; Kikuzawa, Nobuhiro
2013-11-01
The performance of LaBr3(Ce) to measure nuclear resonance fluorescence (NRF) excitations is discussed in terms of limits of detection and in comparison with high-purity germanium (HPGe) detectors near the 2 MeV region where many NRF excitation levels from special nuclear materials are located. The NRF experiment was performed at the High Intensity γ-ray Source (HIγS) facility. The incident γ-rays, of 2.12 MeV energy, hit a B4C target to excite the 11B nuclei to the first excitation level. The statistical-sensitive non-linear peak clipping (SNIP) algorithm was implemented to eliminate the background and enhance the limits of detection for the spectra measured with LaBr3(Ce). Both detection and determination limits were deduced from the experimental data.
NASA Astrophysics Data System (ADS)
Sanetullaev, A.; Kanungo, R.; Tanaka, J.; Alcorta, M.; Andreoiu, C.; Bender, P.; Chen, A. A.; Christian, G.; Davids, B.; Fallis, J.; Fortin, J. P.; Galinski, N.; Gallant, A. T.; Garrett, P. E.; Hackman, G.; Hadinia, B.; Ishimoto, S.; Keefe, M.; Krücken, R.; Lighthall, J.; McNeice, E.; Miller, D.; Purcell, J.; Randhawa, J. S.; Roger, T.; Rojas, A.; Savajols, H.; Shotter, A.; Tanihata, I.; Thompson, I. J.; Unsworth, C.; Voss, P.; Wang, Z.
2016-04-01
The first measurement of the one-neutron transfer reaction 11Li(p,d)10Li performed using the IRIS facility at TRIUMF with a 5.7 A MeV11Li beam interacting with a solid H2 target is reported. The 10Li residue was populated strongly as a resonance peak with energy Er = 0.62 ± 0.04 MeV having a total width Γ = 0.33 ± 0.07 MeV. The angular distribution of this resonance is characterized by neutron occupying the 1p1/2 orbital. A DWBA analysis yields a spectroscopic factor of 0.67 ± 0.12 for p1/2 removal strength from the ground state of 11Li to the region of the peak.
The structure of {sup 117}Te and {sup 118}Te and collectivity in {sup 118}Te
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duyar, C.; Draper, J.E.; Rubel, E.C.
1993-10-01
The reactions {sup 82}Se({sup 40}Ar,5n) and {sup 76}Ge({sup 48}Ca, 6 n) (beam energies 180MeV and 190MeV, respectively) were used to populate high spins states of {sup 117}Te and {sup 118}Te, respectively. {gamma} - {gamma} coincidences, E{sub gamma}, and coincidence I{sub gamma} have been measured. Angular correlation/distribution analysis has been made. {sup 117}Te has been extended to spin {approximately} 51/2. Our results do not support the two isolated bands found by Sharma et al. {sup 118}Te has been also extended to spin {approximately}22. A rotational band was found in {sup 118}Te with an average J {approximately}42h{sup 2}/MeV, corresponding to a {Beta}more » {approximately} 0.2.« less
Gavade, Chaitali; Singh, N L; Khanna, P K; Shah, Sunil
2015-12-01
In order to study structural, thermal, optical and dielectric behaviors of composites, the films of Cu/polystyrene nanocomposites were synthesized at different concentrations of Cu-nanoparticles. These polymer nanocomposites were irradiated with carbon (85 MeV) and silicon (120 MeV) ions at different fluences. The samples were characterized using different techniques viz: X-ray diffraction, UV-visible spectroscopy, differential scanning calorimetry, and impedance gain phase analyzer. A noticeable increase in the intensity of X-ray diffraction peaks was observed after irradiation with 120 MeV Si-ions, which may be attributed to radiation-induced cross-linking in polymer. Optical properties like band gap was estimated for pure polymer and nanocomposite films from their optical absorption spectra in the wavelength region 200-800 nm. It was found that the band gap value shifted to lower energy (from 4.38 eV to 3.40 eV) on doping with silver nanoparticles and also upon irradiation. Differential scanning calorimetry analysis revealed an increase in the glass transition temperature upon irradiation, which may be attributed to cross linking of polymer chain due to ion beam irradiation which is also corroborated with XRD analysis. Dependence of dielectric properties on frequency, ions and filler concentration was studied. The results revealed the enhancement in dielectric properties after doping nanoparticles and also upon irradiation. It was observed that the effect of Si-beam is more effectual than the C-beam because of large electronic energy loss of heavy ion.
Systematic analysis of inelastic α scattering off self-conjugate A =4 n nuclei
NASA Astrophysics Data System (ADS)
Adachi, S.; Kawabata, T.; Minomo, K.; Kadoya, T.; Yokota, N.; Akimune, H.; Baba, T.; Fujimura, H.; Fujiwara, M.; Funaki, Y.; Furuno, T.; Hashimoto, T.; Hatanaka, K.; Inaba, K.; Ishii, Y.; Itoh, M.; Iwamoto, C.; Kawase, K.; Maeda, Y.; Matsubara, H.; Matsuda, Y.; Matsuno, H.; Morimoto, T.; Morita, H.; Murata, M.; Nanamura, T.; Ou, I.; Sakaguchi, S.; Sasamoto, Y.; Sawada, R.; Shimizu, Y.; Suda, K.; Tamii, A.; Tameshige, Y.; Tsumura, M.; Uchida, M.; Uesaka, T.; Yoshida, H. P.; Yoshida, S.
2018-01-01
We systematically measured the differential cross sections of inelastic α scattering off self-conjugate A =4 n nuclei at two incident energies Eα=130 MeV and 386 MeV at Research Center for Nuclear Physics, Osaka University. The measured cross sections were analyzed by the distorted-wave Born-approximation (DWBA) calculation using the single-folding potentials, which are obtained by folding macroscopic transition densities with the phenomenological α N interaction. The DWBA calculation with the density-dependent α N interaction systematically overestimates the cross sections for the Δ L =0 transitions. However, the DWBA calculation using the density-independent α N interaction reasonably well describes all the transitions with Δ L =0 -4. We examined uncertainties in the present DWBA calculation stemming from the macroscopic transition densities, distorting potentials, phenomenological α N interaction, and coupled channel effects in 12C. It was found that the DWBA calculation is not sensitive to details of the transition densities nor the distorting potentials, and the phenomenological density-independent α N interaction gives reasonable results. The coupled-channel effects are negligibly small for the 21+ and 31- states in 12C, but not for the 02+ state. However, the DWBA calculation using the density-independent interaction at Eα=386 MeV is still reasonable even for the 02+ state. We concluded that the macroscopic DWBA calculations using the density-independent interaction are reliably applicable to the analysis of inelastic α scattering at Eα˜100 MeV /u .
R-matrix analysis of reactions in the 9B compound system applied to the 7Li problem in BBN
NASA Astrophysics Data System (ADS)
Paris, M.; Hale, G.; Hayes-Sterbenz, A.; Jungman, G.
2016-01-01
Recent activity in solving the ‘lithium problem’ in big bang nucleosynthesis has focused on the role that putative resonances may play in resonance-enhanced destruction of 7Li. Particular attention has been paid to the reactions involving the 9B compound nuclear system, d+7Be → 9B. These reactions are analyzed via the multichannel, two-body unitary R-matrix method using the code EDA developed by Hale and collaborators. We employ much of the known elastic and reaction data, in a four-channel treatment. The data include elastic 3He +6Li differential cross sections from 0.7 to 2.0 MeV, integrated reaction cross sections for energies from 0.7 to 5.0 MeV for 6Li(3He,p)8Be* and from 0.4 to 5.0 MeV for the 6Li(3He,d)7Be reaction. Capture data have been added to an earlier analysis with integrated cross section measurements from 0.7 to 0.825 MeV for 6Li(3He,γ)9B. The resulting resonance parameters are compared with tabulated values, and previously unidentified resonances are noted. Our results show that there are no near d+7Be threshold resonances with widths that are 10’s of keV and reduce the likelihood that a resonance-enhanced mass-7 destruction mechanism, as suggested in recently published work, can explain the 7Li problem.
Ion Beam Irradiation Studies Of Ultrananocrystalline Diamond (UNCD)
NASA Astrophysics Data System (ADS)
Kayani, A.; Garratt, E.; AlFaify, S.; Dissanayake, A.; Tecos, G.; Mancini, D. C.; Syed, M.
2011-06-01
Investigations into the effects of high-energy ion bombardment of ultrananocrystalline diamond (UNCD) thin films was performed using 3 and 6 MeV protons and 24 MeV F4+, with the fluence of 2.1×1017 ions/cm2, 2.9×1017 ions/cm2, and 6.7×1015 ions/cm2 respectively. Objective of the research is to investigate the effect of structural damage on the physical properties of the material and compare it with the structure of unirradiated and N doped UNCD. Pre- and post-irradiated samples were analyzed by ion beam analysis (IBA) measurements, Raman spectroscopy, atomic force microscopy (AFM) and scanning electron microscopy (SEM). IBA measurements including Rutherford backscattering spectrometry (RBS), non-Rutherford backscattering spectrometry (NRBS) and elastic recoil detection analysis (ERDA) were used to determine elemental concentration of pre- and post-irradiated samples. Visible Raman spectra corresponding to samples irradiated at 3 and 6 MeV protons did not show much variation. For 24 MeV F4+ irradiated sample, significant changes were observed, particularly the loss of a shoulder at 1179 cm-1 and sharpening of the G peak at around 1532 cm-1, indicating possible significant changes at the grain boundary and increase in sp2 phase. AFM measurements show a reduction in RMS roughness after bombardment possibly due to the graphitization of the UNCD surface. The results of IBA measurements did not show any change in the elemental concentration or interface region between film and substrate.
Absolute prompt-gamma yield measurements for ion beam therapy monitoring
NASA Astrophysics Data System (ADS)
Pinto, M.; Bajard, M.; Brons, S.; Chevallier, M.; Dauvergne, D.; Dedes, G.; De Rydt, M.; Freud, N.; Krimmer, J.; La Tessa, C.; Létang, J. M.; Parodi, K.; Pleskač, R.; Prieels, D.; Ray, C.; Rinaldi, I.; Roellinghoff, F.; Schardt, D.; Testa, E.; Testa, M.
2015-01-01
Prompt-gamma emission detection is a promising technique for hadrontherapy monitoring purposes. In this regard, obtaining prompt-gamma yields that can be used to develop monitoring systems based on this principle is of utmost importance since any camera design must cope with the available signal. Herein, a comprehensive study of the data from ten single-slit experiments is presented, five consisting in the irradiation of either PMMA or water targets with lower and higher energy carbon ions, and another five experiments using PMMA targets and proton beams. Analysis techniques such as background subtraction methods, geometrical normalization, and systematic uncertainty estimation were applied to the data in order to obtain absolute prompt-gamma yields in units of prompt-gamma counts per incident ion, unit of field of view, and unit of solid angle. At the entrance of a PMMA target, where the contribution of secondary nuclear reactions is negligible, prompt-gamma counts per incident ion, per millimetre and per steradian equal to (124 ± 0.7stat ± 30sys) × 10-6 for 95 MeV u-1 carbon ions, (79 ± 2stat ± 23sys) × 10-6 for 310 MeV u-1 carbon ions, and (16 ± 0.07stat ± 1sys) × 10-6 for 160 MeV protons were found for prompt gammas with energies higher than 1 MeV. This shows a factor 5 between the yields of two different ions species with the same range in water (160 MeV protons and 310 MeV u-1 carbon ions). The target composition was also found to influence the prompt-gamma yield since, for 300/310 MeV u-1 carbon ions, a 42% greater yield ((112 ± 1stat ± 22sys) × 10-6 counts ion-1 mm-1 sr-1) was obtained with a water target compared to a PMMA one.
Optimization of {sup 6}LiF:ZnS(Ag) Scintillator Light Yield Using Geant4
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yehuda-Zada, Y.; Ben-Gurion University; Pritchard, K.
2015-07-01
Neutrons provide an effective tool to probe materials structure. Neutron diffraction is a method to determine the atomic and magnetic structure of a material based on neutron scattering. By this method a collimated incident beam of thermal neutrons heat the examined sample and based on the obtained diffraction pattern information on the structure of the material is provided. Research for developing a novel cold neutron detector for Chromatic Analysis Neutron Diffractometer Or Reflectometer (CANDOR) is underway at the NIST center for neutron research. The system unique design is aimed to provide over ten times fold faster analysis of materials thanmore » conventional system. In order to achieve the fast analysis a large number of neutron detectors is required. A key design constraint for this detector is the thickness of the neutron sensitive element. This is met using {sup 6}LiF:ZnS(Ag) scintillation material with embedded wavelength shifting (WLS) fibers conducting scintillation light to silicon photomultiplier photo-sensors. The detector sensitivity is determined by both the neutron capture probability ({sup 6}Li density) and the detectable light output produced by the ZnS(Ag) ionization, the latter of which is hindered by the fluorescence absorption of the scintillation light by the ZnS. Tradeoffs between the neutron capture probability, stimulated light production and light attenuation for determining the optimal stoichiometry of the {sup 6}LiF and ZnS(Ag) as well as the volume ratio of scintillator and fiber. Simulations performed using the GEANT4 Monte Carlo package were made in order to optimize the detector design. GEANT4 enables the investigation of the neutron interaction with the detector, the ionization process and the light transfer process following the nuclear process. The series of conversions required for this detector were modelled: - A cold neutron enters the sensor and is captured by {sup 6}Li in the scintillator mixture ({sup 6}Li (n,α) {sup 3}H reaction). The study of investigating the capture process probability for neutron energy of 5.1 meV to 2.27 meV (4 - 6 A) is presented. - Alpha particles and tritons travel for a few microns in the scintillation material (α ∼0.007 mm, T ∼0.04 mm) losing energy and ionizing the ZnS. The mean free path of the two particles in each of the component materials and the complete compound was investigated. - The ionization of the ZnS(Ag) scintillation material produces blue light photons with luminescence wavelength of 450 nm. The amount of light output produced for different grain sizes of ZnS is discussed. - A large portion of the scintillation photons are reabsorbed during their passage through the scintillation material. - The blue photons that reach the WLS fibers are absorbed by fluorescent dye and are re-emitted as green photons, conducted by the fiber to the SiPM photo-sensor. This work presents the CANDOR unique design and its design constrains, the results measured by the ultra-thin {sup 6}LiF:ZnS(Ag)-based neutron detector versus the simulation results for several binder concentrations. The light measurement attenuation results along with the measured stopping power were utilized to predict the sensitivity results of configuration with different ZnS grain size, weight ratios and fibers geometry (number and location). The simulations enable to optimize the final sensor design. This design successfully achieved both the high gamma rejection with a sensitive and accurate neutron event detection of 80 percent. (authors)« less
A Statictical Study of 3He Enhancement in the High-Energy Solar Particles
NASA Astrophysics Data System (ADS)
Laivola, Jarno; Torsti, J.; Kocharov, L.
2003-07-01
Energetic particle observations of the ERNE instrument (the Energetic and Relativistic Nuclei and Electron experiment) onboard the Solar and Heliospheric Observatory enable the measurements of the 3 He flux beyond 15 MeV nucleon-1 with a good statistical resolution. An overview of the ERNE observations for the period from 8 February 1999 to 7 December 2000 is reported and a comprehensive statistical study is performed to learn regularities of 3 He enhancements in the high-energy range of 15-30 MeV nucleon -1 . Significant intensities of 3 He are detected in all event days with 4 He intensity exceeding ≈ 0.5 ion per (m2 s sr MeV nucleon-1 ). The abundance ratio 3 He/4 He is measured to vary within the range ˜ 0.003-2, which is well above the corresponding solar wind value. A histogram of the daily 3 He/4 He ratio reveals a sharp maximum at 3 He/4 He ≈ 0.01. Observations and analysis The early studies of the 3 He-rich solar energetic particle (SEP) events are mostly made in low energies, ˜ 1 MeV nucleon-1 , (Ko charov & Ko charov 1984, Reames, Meyer, & von Rosenvinge 1994, and references therein) but some measurements beyond 10 MeV nucleon-1 has been also carried out (Clayton, Guzik, & Wefel 2000, Bakaldin et al. 2003, Torsti et al. 2002, 2003, and references therein). This survey of SEP events is based on the particle flux measurements by ERNE/HED particle telescope (Torsti et al. 1995) from 8 February 1999 till 7 December 2000. Both helium isotop es, 3 He and 4 He, were detected in the energy channel 15-30 MeV nucleon-1 and the average geometric factor for the studied isotop es in this channel is 30.5 cm2 sr. During the selected period there were some data gaps lasting from few hours to couple of days when either the spacecraft, or more often, the instrument was not in the observation mode. There were also a couple of strong solar events, like the events in 14 July 2000 and 9 November 2000, producing the extreme particle fluxes exceeding the analysis capacity of ERNE. In those o ccasions, the data have been excluded from the analysis. Figure 1 plots time profiles of 3 He and 4 He daily count rates during 19992000. The slowly-changing line in the uppermost panel shows a lower limit for
NEOS Data and the Origin of the 5 MeV Bump in the Reactor Antineutrino Spectrum
NASA Astrophysics Data System (ADS)
Huber, Patrick
2017-01-01
We perform a combined analysis of recent NEOS and Daya Bay data on the reactor antineutrino spectrum. This analysis includes approximately 1.5 million antineutrino events, which is the largest neutrino event sample analyzed to date. We use a double ratio which cancels flux model dependence and related uncertainties as well as the effects of the detector response model. We find at 3-4 standard deviation significance level, that plutonium-239 and plutonium-241 are disfavored as the single source for the so-called 5 MeV bump. This analysis method has general applicability and, in particular, with higher statistics data sets, will be able to shed significant light on the issue of the bump. With some caveats, this should also allow us to improve the sensitivity for sterile neutrino searches in NEOS.
Coupled attenuation and multiscale damage model for composite structures
NASA Astrophysics Data System (ADS)
Moncada, Albert M.; Chattopadhyay, Aditi; Bednarcyk, Brett; Arnold, Steven M.
2011-04-01
Composite materials are widely used in many applications for their high strength, low weight, and tailorability for specific applications. However, the development of robust and reliable methodologies to detect micro level damage in composite structures has been challenging. For composite materials, attenuation of ultrasonic waves propagating through the media can be used to determine damage within the material. Currently available numerical solutions for attenuation induce arbitrary damage, such as fiber-matrix debonding or inclusions, to show variations between healthy and damaged states. This paper addresses this issue by integrating a micromechanics analysis to simulate damage in the form of a fiber-matrix crack and an analytical model for calculating the attenuation of the waves when they pass through the damaged region. The hybrid analysis is validated by comparison with experimental stress-strain curves and piezoelectric sensing results for attenuation measurement. The results showed good agreement between the experimental stress-strain curves and the results from the micromechanics analysis. Wave propagation analysis also showed good correlation between simulation and experiment for the tested frequency range.
An Investigation of New Snow Water Equivalence Sensing Modalities
NASA Astrophysics Data System (ADS)
Frolik, J.; Skalka, C.; Wemple, B.
2008-12-01
It is well known that snowpack is highly variable and influenced by a range of factors, including topography and vegetation cover. As such, single point measurements may be viewed as being inadequate to characterize snowpack in a given area. Thus motivated by the desire for distributed sensing, this work presents results of a proof-of-concept investigation for new, low-cost, snow water equivalence (SWE) sensors based on the attenuation of microwave and gamma radiation. First, our work considers the attenuation of microwave signals at 2.4 GHz and 5 GHz due to an accumulating snowpack. These frequencies coincide with those used for common wireless networks and thus our proposed sensor can leverage existing hardware designs which are low-cost and power efficient. Second, we present attenuation data for radiation energy occurring between 500 keV and 1 MeV. These results were obtained utilizing a radiation detector based on Cadmium Zinc Telluride (CZT) technology. The proposed sensor will leverage recent investments such CZT based designs for homeland security applications. We contend that sensors based on these modalities will be low-cost and low-energy and thus readily integrated with wireless sensor network hardware for distributed monitoring. In addition, these sensors will be compact and thus can be placed in locations not feasible for current SWE sensor designs (e.g., snow pillows) or in locations too dangerous for snow course measurements (e.g., areas prone to avalanche). Since neither sensing methods requires contact with the snowpack, these modalities are also immune to snow bridging effects which plague existing designs. We also present preliminary findings of work conducted in a mountainous forested setting in northern New England which examines the influence of forest vegetation on snowpack.
Dose Analysis of the Model 112A Pulserad Pulsed X-Ray Generator by Its Cyltran
1989-12-01
field was performed by R. B. Pietruszka [Ref. 1] using the dosimetry system which consists of Thermoluminescent Dosimeter ( TLD ) and associated TLD ...has the same pattern at a specific angle of the dominant electron flow. For a Marx charge of 75 kV, Figure 18 shows the absorbed dose in TLD normalized... Electron energy (1.66 MeV to 0.05 MeV) 3 materials 56 minutes 45 minutes (Ta, Al, TLD ) 68 APPENDIX F. MEASURED EXPOSURE VARIATION Marx Charge 75 kV
Observation of an alternative χc 0(2 P ) candidate in e+e-→J /ψ D D ¯
NASA Astrophysics Data System (ADS)
Chilikin, K.; Adachi, I.; Aihara, H.; Al Said, S.; Asner, D. M.; Aulchenko, V.; Ayad, R.; Babu, V.; Badhrees, I.; Bakich, A. M.; Bansal, V.; Barberio, E.; Besson, D.; Bhardwaj, V.; Bhuyan, B.; Biswal, J.; Bobrov, A.; Bondar, A.; Bozek, A.; Bračko, M.; Browder, T. E.; Červenkov, D.; Chekelian, V.; Chen, A.; Cheon, B. G.; Cho, K.; Choi, Y.; Cinabro, D.; Dash, N.; Di Carlo, S.; Doležal, Z.; Drásal, Z.; Dutta, D.; Eidelman, S.; Farhat, H.; Fast, J. E.; Ferber, T.; Fulsom, B. G.; Gaur, V.; Gabyshev, N.; Garmash, A.; Gillard, R.; Goldenzweig, P.; Haba, J.; Hara, T.; Hayasaka, K.; Hou, W.-S.; Inami, K.; Ishikawa, A.; Itoh, R.; Iwasaki, Y.; Jacobs, W. W.; Jaegle, I.; Jeon, H. B.; Jin, Y.; Joffe, D.; Joo, K. K.; Julius, T.; Kang, K. H.; Karyan, G.; Katrenko, P.; Kim, D. Y.; Kim, H. J.; Kim, J. B.; Kim, K. T.; Kim, M. J.; Kim, S. H.; Kim, Y. J.; Kinoshita, K.; Kodyš, P.; Korpar, S.; Kotchetkov, D.; Križan, P.; Krokovny, P.; Kuhr, T.; Kulasiri, R.; Kuzmin, A.; Kwon, Y.-J.; Lange, J. S.; Li, L.; Li Gioi, L.; Libby, J.; Liventsev, D.; Lubej, M.; Luo, T.; Masuda, M.; Matsuda, T.; Matvienko, D.; Miyabayashi, K.; Miyata, H.; Mizuk, R.; Mohanty, G. B.; Moon, H. K.; Mori, T.; Mussa, R.; Nakano, E.; Nakao, M.; Nanut, T.; Nath, K. J.; Natkaniec, Z.; Nayak, M.; Niiyama, M.; Nisar, N. K.; Nishida, S.; Ogawa, S.; Okuno, S.; Olsen, S. L.; Ono, H.; Pakhlov, P.; Pakhlova, G.; Pal, B.; Pardi, S.; Park, H.; Paul, S.; Pestotnik, R.; Piilonen, L. E.; Pulvermacher, C.; Ritter, M.; Sahoo, H.; Sakai, Y.; Salehi, M.; Sandilya, S.; Santelj, L.; Sanuki, T.; Schneider, O.; Schnell, G.; Schwanda, C.; Seino, Y.; Senyo, K.; Seon, O.; Sevior, M. E.; Shebalin, V.; Shen, C. P.; Shibata, T.-A.; Shiu, J.-G.; Sokolov, A.; Solovieva, E.; Starič, M.; Sumiyoshi, T.; Takizawa, M.; Tamponi, U.; Tanida, K.; Tenchini, F.; Trabelsi, K.; Uchida, M.; Uehara, S.; Uglov, T.; Uno, S.; Usov, Y.; Van Hulse, C.; Varner, G.; Vinokurova, A.; Vossen, A.; Wang, C. H.; Wang, M.-Z.; Wang, P.; Watanabe, M.; Watanabe, Y.; Widmann, E.; Won, E.; Yamamoto, H.; Yamashita, Y.; Ye, H.; Yuan, C. Z.; Yusa, Y.; Zhang, Z. P.; Zhilich, V.; Zhulanov, V.; Zupanc, A.; Belle Collaboration
2017-06-01
We perform a full amplitude analysis of the process e+e-→J /ψ D D ¯ , where D refers to either D0 or D+. A new charmoniumlike state X*(3860 ) that decays to D D ¯ is observed with a significance of 6.5 σ . Its mass is (3862-32+26-13+40) MeV /c2 , and its width is (201-67+154-82+88) MeV . The JP C=0++ hypothesis is favored over the 2++ hypothesis at the level of 2.5 σ . The analysis is based on the 980 fb-1 data sample collected by the Belle detector at the asymmetric-energy e+e- collider KEKB.
Nuclear rainbow in elastic scattering of {sup 9}Be nuclei
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glukhov, Yu. A., E-mail: gloukhov@inbox.ru; Ogloblin, A. A.; Artemov, K. P.
2010-01-15
A systematic investigation of the elastic scattering of the {sup 9}Be nucleus, which is among themost loosely bound stable nuclei was performed.Differential cross sections for elastic {sup 9}Be + {sup 16}O scattering were measured at a c.m. energy of 47.5 MeV (beam of 132-MeV {sup 16}O nuclei). Available data at different energy values and data for neighboring nuclei were included in our analysis. As a result, the very fact of rainbow scattering was reliably established for the first time in systems involving {sup 9}Be. In addition, the analysis in question made it possible to identify Airy minima and to determinemore » unambiguously the nucleus-nucleus potential with a high probability.« less
A I-V analysis of irradiated Gallium Arsenide solar cells
NASA Technical Reports Server (NTRS)
Heulenberg, A.; Maurer, R. H.; Kinnison, J. D.
1991-01-01
A computer program was used to analyze the illuminated I-V characteristics of four sets of gallium arsenide (GaAs) solar cells irradiated with 1-MeV electrons and 10-MeV protons. It was concluded that junction regions (J sub r) dominate nearly all GaAs cells tested, except for irradiated Mitsubishi cells, which appear to have a different doping profile. Irradiation maintains or increases the dominance by J sub r. Proton irradiation increases J sub r more than does electron irradiation. The U.S. cells were optimized for beginning of life (BOL) and the Japanese for end of life (EOL). I-V analysis indicates ways of improving both the BOL and EOL performance of GaAs solar cells.
50-500 MeV observations of LMC supernova 1987A
NASA Astrophysics Data System (ADS)
Summer, T. J.; Rochester, G. K.; Sood, R. K.; Thomas, J.; Waldron, L.; Manchanda, R. K.; Frye, G.; Jenkins, T.; Koga, R.; Staubert, R.; Kendziorra, E.; Ubertini, P.; Bazzano, A.; La Padula, C.
Since the discovery of the supernova outburst in the LMC in 1987, two attempts (on day 55 and day 407) have been made to measure the high energy gamma-ray flux in the range 50-500 MeV, by using a balloon-borne spark chamber telescope. On day 55, no positive signal was seen from the source. A 3 sigma upper limit of 2.9 x 10 to the -5th ph/sq cm s was obtained after the analysis of the spark chamber data. Preliminary analysis of the quick look data obtained in the second flight shows that the gamma-ray flux even on day 407 was less than 9 x 10 to the -4th ph/sq cm s (3 sigma).
A systematic investigation of the (α, 2nγ) reaction on medium-heavy nuclei
NASA Astrophysics Data System (ADS)
Fields, C. A.; De Boer, F. W. N.; Ristinen, R. A.; Smith, P. A.; Sugarbaker, E.
1982-03-01
Exclusive neutron spectra and angular distributions have been measured for 28-35 MeV (α, 2nγ) reactions on various nuclei in the 80 ≦ A ≦ 210 region. Pre-equilibrium processes dominate the 35 MeV (α, 2nγ) reaction mechanism in much of this region. Analysis of systematic variation in the neutron spectrum parameters shows that the reaction mechanism is strongly correlated with the target neutron excess parameter ( N- Z/ A. Analysis of the γ-decay of the entry states shows that well-defined incident angular momentum windows exist for the pre-etjuilibrium (α, 2nγ) reaction. These features are discussed in terms of various models for the reaction mechanism.
Koo, Hyun Jung; Kim, Mi Young; Koo, Ja Hwan; Sung, Yu Sub; Jung, Jiwon; Kim, Sung-Han; Choi, Chang-Min; Kim, Hwa Jung
2017-01-01
Radiologists have used margin characteristics based on routine visual analysis; however, the attenuation changes at the margin of the lesion on CT images have not been quantitatively assessed. We established a CT-based margin analysis method by comparing a target lesion with normal lung attenuation, drawing a slope to represent the attenuation changes. This approach was applied to patients with invasive mucinous adenocarcinoma (n = 40) or bacterial pneumonia (n = 30). Correlations among multiple regions of interest (ROIs) were obtained using intraclass correlation coefficient (ICC) values. CT visual assessment, margin and texture parameters were compared for differentiating the two disease entities. The attenuation and margin parameters in multiple ROIs showed excellent ICC values. Attenuation slopes obtained at the margins revealed a difference between invasive mucinous adenocarcinoma and pneumonia (P<0.001), and mucinous adenocarcinoma produced a sharply declining attenuation slope. On multivariable logistic regression analysis, pneumonia had an ill-defined margin (odds ratio (OR), 4.84; 95% confidence interval (CI), 1.26-18.52; P = 0.02), ground-glass opacity (OR, 8.55; 95% CI, 2.09-34.95; P = 0.003), and gradually declining attenuation at the margin (OR, 12.63; 95% CI, 2.77-57.51, P = 0.001). CT-based margin analysis method has a potential to act as an imaging parameter for differentiating invasive mucinous adenocarcinoma and bacterial pneumonia.
Takada, Masashi; Kosako, Kazuaki; Oishi, Koji; Nakamura, Takashi; Sato, Kouichi; Kamiyama, Takashi; Kiyanagi, Yoshiaki
2013-03-01
Angular distributions of absorbed dose of Bremsstrahlung photons and secondary electrons at a wide range of emission angles from 0 to 135°, were experimentally obtained using an ion chamber with a 0.6 cm(3) air volume covered with or without a build-up cap. The Bremsstrahlung photons and electrons were produced by 18-, 28- and 38-MeV electron beams bombarding tungsten, copper, aluminium and carbon targets. The absorbed doses were also calculated from simulated photon and electron energy spectra by multiplying simulated response functions of the ion chambers, simulated with the MCNPX code. Calculated-to-experimental (C/E) dose ratios obtained are from 0.70 to 1.57 for high-Z targets of W and Cu, from 15 to 135° and the C/E range from 0.6 to 1.4 at 0°; however, the values of C/E for low-Z targets of Al and C are from 0.5 to 1.8 from 0 to 135°. Angular distributions at the forward angles decrease with increasing angles; on the other hand, the angular distributions at the backward angles depend on the target species. The dependences of absorbed doses on electron energy and target thickness were compared between the measured and simulated results. The attenuation profiles of absorbed doses of Bremsstrahlung beams at 0, 30 and 135° were also measured.
NASA Astrophysics Data System (ADS)
Lagomarsino, Stefano; Sciortino, Silvio; Gelli, Nicla; Flatae, Assegid M.; Gorelli, Federico; Santoro, Mario; Chiari, Massimo; Czelusniac, Caroline; Massi, Mirko; Taccetti, Francesco; Agio, Mario; Giuntini, Lorenzo
2018-05-01
The line for the pulsed beam of the 3 MeV Tandetron accelerator at LABEC (Florence) has been upgraded for ion implantation experiments aiming at the fabrication of single-photon emitters in a solid-state matrix. A system based on Al attenuators has been calibrated in order to extend the energy range of the implanted ions from MeV down to the tens of keV. A new motorized XY stage has been installed in the implantation chamber for achieving ultra-fine control on the position of each implanted ion, allowing to reach the scale imposed by lateral straggling. A set-up for the activation of the implanted ions has been developed, based on an annealing furnace operating under controlled high-vacuum conditions. The first experiments have been performed with silicon ions implanted in diamond and the luminescent signal of the silicon-vacancy (SiV) center, peaked at 738 nm, has been observed for a wide range of implantation fluences (108 ÷ 1015 cm-2) and implantation depths (from a few nm to 2.4 μm). Studies on the efficiency of the annealing process have been performed and the activation yield has been measured to range from 1% to 3%. The implantation and annealing facility has thus been tuned for the production of SiV centers in diamond, but is in principle suitable for other ion species and solid-state matrices.
Resonant Inverse Compton Scattering Spectra from Highly Magnetized Neutron Stars
NASA Astrophysics Data System (ADS)
Wadiasingh, Zorawar; Baring, Matthew G.; Gonthier, Peter L.; Harding, Alice K.
2018-02-01
Hard, nonthermal, persistent pulsed X-ray emission extending between 10 and ∼150 keV has been observed in nearly 10 magnetars. For inner-magnetospheric models of such emission, resonant inverse Compton scattering of soft thermal photons by ultrarelativistic charges is the most efficient production mechanism. We present angle-dependent upscattering spectra and pulsed intensity maps for uncooled, relativistic electrons injected in inner regions of magnetar magnetospheres, calculated using collisional integrals over field loops. Our computations employ a new formulation of the QED Compton scattering cross section in strong magnetic fields that is physically correct for treating important spin-dependent effects in the cyclotron resonance, thereby producing correct photon spectra. The spectral cutoff energies are sensitive to the choices of observer viewing geometry, electron Lorentz factor, and scattering kinematics. We find that electrons with energies ≲15 MeV will emit most of their radiation below 250 keV, consistent with inferred turnovers for magnetar hard X-ray tails. More energetic electrons still emit mostly below 1 MeV, except for viewing perspectives sampling field-line tangents. Pulse profiles may be singly or doubly peaked dependent on viewing geometry, emission locale, and observed energy band. Magnetic pair production and photon splitting will attenuate spectra to hard X-ray energies, suppressing signals in the Fermi-LAT band. The resonant Compton spectra are strongly polarized, suggesting that hard X-ray polarimetry instruments such as X-Calibur, or a future Compton telescope, can prove central to constraining model geometry and physics.
Magnetic dipole excitations of 50Cr
NASA Astrophysics Data System (ADS)
Pai, H.; Beck, T.; Beller, J.; Beyer, R.; Bhike, M.; Derya, V.; Gayer, U.; Isaak, J.; Krishichayan, Kvasil, J.; Löher, B.; Nesterenko, V. O.; Pietralla, N.; Martínez-Pinedo, G.; Mertes, L.; Ponomarev, V. Yu.; Reinhard, P.-G.; Repko, A.; Ries, P. C.; Romig, C.; Savran, D.; Schwengner, R.; Tornow, W.; Werner, V.; Wilhelmy, J.; Zilges, A.; Zweidinger, M.
2016-01-01
The low-lying M 1 strength of the open-shell nucleus 50Cr has been studied with the method of nuclear resonance fluorescence up to 9.7 MeV using bremsstrahlung at the superconducting Darmstadt linear electron accelerator S-DALINAC and Compton backscattered photons at the High Intensity γ -ray Source (HI γ S ) facility between 6 and 9.7 MeV of the initial photon energy. Fifteen 1+ states have been observed between 3.6 and 9.7 MeV. Following our analysis the lowest 1+ state at 3.6 MeV can be considered as an isovector orbital mode with some spin admixture. The obtained results generally match the estimations and trends typical for the scissors-like mode. Detailed calculations within the Skyrme quasiparticle random-phase-approximation method and the large-scale shell model justify our conclusions. The calculated distributions of the orbital current for the lowest 1+-state suggest the schematic view of Lipparini and Stringari (isovector rotation-like oscillations inside the rigid surface) rather than the scissors-like picture of Lo Iudice and Palumbo. The spin M 1 resonance is shown to be mainly generated by spin-flip transitions between the orbitals of the f p shell.
Properties of nuclear matter from macroscopic-microscopic mass formulas
NASA Astrophysics Data System (ADS)
Wang, Ning; Liu, Min; Ou, Li; Zhang, Yingxun
2015-12-01
Based on the standard Skyrme energy density functionals together with the extended Thomas-Fermi approach, the properties of symmetric and asymmetric nuclear matter represented in two macroscopic-microscopic mass formulas: Lublin-Strasbourg nuclear drop energy (LSD) formula and Weizsäcker-Skyrme (WS*) formula, are extracted through matching the energy per particle of finite nuclei. For LSD and WS*, the obtained incompressibility coefficients of symmetric nuclear matter are K∞ = 230 ± 11 MeV and 235 ± 11 MeV, respectively. The slope parameter of symmetry energy at saturation density is L = 41.6 ± 7.6 MeV for LSD and 51.5 ± 9.6 MeV for WS*, respectively, which is compatible with the liquid-drop analysis of Lattimer and Lim [4]. The density dependence of the mean-field isoscalar and isovector effective mass, and the neutron-proton effective masses splitting for neutron matter are simultaneously investigated. The results are generally consistent with those from the Skyrme Hartree-Fock-Bogoliubov calculations and nucleon optical potentials, and the standard deviations are large and increase rapidly with density. A better constraint for the effective mass is helpful to reduce uncertainties of the depth of the mean-field potential.
Observation of J/ψp Resonances Consistent with Pentaquark States in Λ_{b}^{0}→J/ψK^{-}p Decays.
Aaij, R; Adeva, B; Adinolfi, M; Affolder, A; Ajaltouni, Z; Akar, S; Albrecht, J; Alessio, F; Alexander, M; Ali, S; Alkhazov, G; Alvarez Cartelle, P; Alves, A A; Amato, S; Amerio, S; Amhis, Y; An, L; Anderlini, L; Anderson, J; Andreassi, G; Andreotti, M; Andrews, J E; Appleby, R B; Aquines Gutierrez, O; Archilli, F; d'Argent, P; Artamonov, A; Artuso, M; Aslanides, E; Auriemma, G; Baalouch, M; Bachmann, S; Back, J J; Badalov, A; Baesso, C; Baldini, W; Barlow, R J; Barschel, C; Barsuk, S; Barter, W; Batozskaya, V; Battista, V; Bay, A; Beaucourt, L; Beddow, J; Bedeschi, F; Bediaga, I; Bel, L J; Bellee, V; Belloli, N; Belyaev, I; Ben-Haim, E; Bencivenni, G; Benson, S; Benton, J; Berezhnoy, A; Bernet, R; Bertolin, A; Bettler, M-O; van Beuzekom, M; Bien, A; Bifani, S; Billoir, P; Bird, T; Birnkraut, A; Bizzeti, A; Blake, T; Blanc, F; Blouw, J; Blusk, S; Bocci, V; Bondar, A; Bondar, N; Bonivento, W; Borghi, S; Borsato, M; Bowcock, T J V; Bowen, E; Bozzi, C; Braun, S; Britsch, M; Britton, T; Brodzicka, J; Brook, N H; Bursche, A; Buytaert, J; Cadeddu, S; Calabrese, R; Calvi, M; Calvo Gomez, M; Campana, P; Campora Perez, D; Capriotti, L; Carbone, A; Carboni, G; Cardinale, R; Cardini, A; Carniti, P; Carson, L; Carvalho Akiba, K; Casse, G; Cassina, L; Castillo Garcia, L; Cattaneo, M; Cauet, Ch; Cavallero, G; Cenci, R; Charles, M; Charpentier, Ph; Chefdeville, M; Chen, S; Cheung, S-F; Chiapolini, N; Chrzaszcz, M; Cid Vidal, X; Ciezarek, G; Clarke, P E L; Clemencic, M; Cliff, H V; Closier, J; Coco, V; Cogan, J; Cogneras, E; Cogoni, V; Cojocariu, L; Collazuol, G; Collins, P; Comerma-Montells, A; Contu, A; Cook, A; Coombes, M; Coquereau, S; Corti, G; Corvo, M; Couturier, B; Cowan, G A; Craik, D C; Crocombe, A; Cruz Torres, M; Cunliffe, S; Currie, R; D'Ambrosio, C; Dall'Occo, E; Dalseno, J; David, P N Y; Davis, A; De Bruyn, K; De Capua, S; De Cian, M; De Miranda, J M; De Paula, L; De Simone, P; Dean, C-T; Decamp, D; Deckenhoff, M; Del Buono, L; Déléage, N; Demmer, M; Derkach, D; Deschamps, O; Dettori, F; Dey, B; Di Canto, A; Di Ruscio, F; Dijkstra, H; Donleavy, S; Dordei, F; Dorigo, M; Dosil Suárez, A; Dossett, D; Dovbnya, A; Dreimanis, K; Dufour, L; Dujany, G; Dupertuis, F; Durante, P; Dzhelyadin, R; Dziurda, A; Dzyuba, A; Easo, S; Egede, U; Egorychev, V; Eidelman, S; Eisenhardt, S; Eitschberger, U; Ekelhof, R; Eklund, L; El Rifai, I; Elsasser, Ch; Ely, S; Esen, S; Evans, H M; Evans, T; Falabella, A; Färber, C; Farley, N; Farry, S; Fay, R; Ferguson, D; Fernandez Albor, V; Ferrari, F; Ferreira Rodrigues, F; Ferro-Luzzi, M; Filippov, S; Fiore, M; Fiorini, M; Firlej, M; Fitzpatrick, C; Fiutowski, T; Fohl, K; Fol, P; Fontana, M; Fontanelli, F; Forty, R; Francisco, O; Frank, M; Frei, C; Frosini, M; Fu, J; Furfaro, E; Gallas Torreira, A; Galli, D; Gallorini, S; Gambetta, S; Gandelman, M; Gandini, P; Gao, Y; García Pardiñas, J; Garra Tico, J; Garrido, L; Gascon, D; Gaspar, C; Gauld, R; Gavardi, L; Gazzoni, G; Geraci, A; Gerick, D; Gersabeck, E; Gersabeck, M; Gershon, T; Ghez, Ph; Gianelle, A; Gianì, S; Gibson, V; Girard, O G; Giubega, L; Gligorov, V V; Göbel, C; Golubkov, D; Golutvin, A; Gomes, A; Gotti, C; Grabalosa Gándara, M; Graciani Diaz, R; Granado Cardoso, L A; Graugés, E; Graverini, E; Graziani, G; Grecu, A; Greening, E; Gregson, S; Griffith, P; Grillo, L; Grünberg, O; Gui, B; Gushchin, E; Guz, Yu; Gys, T; Hadavizadeh, T; Hadjivasiliou, C; Haefeli, G; Haen, C; Haines, S C; Hall, S; Hamilton, B; Han, X; Hansmann-Menzemer, S; Harnew, N; Harnew, S T; Harrison, J; He, J; Head, T; Heijne, V; Hennessy, K; Henrard, P; Henry, L; Hernando Morata, J A; van Herwijnen, E; Heß, M; Hicheur, A; Hill, D; Hoballah, M; Hombach, C; Hulsbergen, W; Humair, T; Hussain, N; Hutchcroft, D; Hynds, D; Idzik, M; Ilten, P; Jacobsson, R; Jaeger, A; Jalocha, J; Jans, E; Jawahery, A; Jing, F; John, M; Johnson, D; Jones, C R; Joram, C; Jost, B; Jurik, N; Kandybei, S; Kanso, W; Karacson, M; Karbach, T M; Karodia, S; Kecke, M; Kelsey, M; Kenyon, I R; Kenzie, M; Ketel, T; Khanji, B; Khurewathanakul, C; Klaver, S; Klimaszewski, K; Kochebina, O; Kolpin, M; Komarov, I; Koopman, R F; Koppenburg, P; Kozeiha, M; Kravchuk, L; Kreplin, K; Kreps, M; Krocker, G; Krokovny, P; Kruse, F; Krzemien, W; Kucewicz, W; Kucharczyk, M; Kudryavtsev, V; Kuonen, A K; Kurek, K; Kvaratskheliya, T; Lacarrere, D; Lafferty, G; Lai, A; Lambert, D; Lanfranchi, G; Langenbruch, C; Langhans, B; Latham, T; Lazzeroni, C; Le Gac, R; van Leerdam, J; Lees, J-P; Lefèvre, R; Leflat, A; Lefrançois, J; Leroy, O; Lesiak, T; Leverington, B; Li, Y; Likhomanenko, T; Liles, M; Lindner, R; Linn, C; Lionetto, F; Liu, B; Liu, X; Loh, D; Longstaff, I; Lopes, J H; Lucchesi, D; Lucio Martinez, M; Luo, H; Lupato, A; Luppi, E; Lupton, O; Lusardi, N; Lusiani, A; Machefert, F; Maciuc, F; Maev, O; Maguire, K; Malde, S; Malinin, A; Manca, G; Mancinelli, G; Manning, P; Mapelli, A; Maratas, J; Marchand, J F; Marconi, U; Marin Benito, C; Marino, P; Marks, J; Martellotti, G; Martin, M; Martinelli, M; Martinez Santos, D; Martinez Vidal, F; Martins Tostes, D; Massafferri, A; Matev, R; Mathad, A; Mathe, Z; Matteuzzi, C; Mauri, A; Maurin, B; Mazurov, A; McCann, M; McCarthy, J; McNab, A; McNulty, R; Meadows, B; Meier, F; Meissner, M; Melnychuk, D; Merk, M; Milanes, D A; Minard, M-N; Mitzel, D S; Molina Rodriguez, J; Monroy, I A; Monteil, S; Morandin, M; Morawski, P; Mordà, A; Morello, M J; Moron, J; Morris, A B; Mountain, R; Muheim, F; Müller, J; Müller, K; Müller, V; Mussini, M; Muster, B; Naik, P; Nakada, T; Nandakumar, R; Nandi, A; Nasteva, I; Needham, M; Neri, N; Neubert, S; Neufeld, N; Neuner, M; Nguyen, A D; Nguyen, T D; Nguyen-Mau, C; Niess, V; Niet, R; Nikitin, N; Nikodem, T; Ninci, D; Novoselov, A; O'Hanlon, D P; Oblakowska-Mucha, A; Obraztsov, V; Ogilvy, S; Okhrimenko, O; Oldeman, R; Onderwater, C J G; Osorio Rodrigues, B; Otalora Goicochea, J M; Otto, A; Owen, P; Oyanguren, A; Palano, A; Palombo, F; Palutan, M; Panman, J; Papanestis, A; Pappagallo, M; Pappalardo, L L; Pappenheimer, C; Parkes, C; Passaleva, G; Patel, G D; Patel, M; Patrignani, C; Pearce, A; Pellegrino, A; Penso, G; Pepe Altarelli, M; Perazzini, S; Perret, P; Pescatore, L; Petridis, K; Petrolini, A; Petruzzo, M; Picatoste Olloqui, E; Pietrzyk, B; Pilař, T; Pinci, D; Pistone, A; Piucci, A; Playfer, S; Plo Casasus, M; Poikela, T; Polci, F; Poluektov, A; Polyakov, I; Polycarpo, E; Popov, A; Popov, D; Popovici, B; Potterat, C; Price, E; Price, J D; Prisciandaro, J; Pritchard, A; Prouve, C; Pugatch, V; Puig Navarro, A; Punzi, G; Qian, W; Quagliani, R; Rachwal, B; Rademacker, J H; Rama, M; Rangel, M S; Raniuk, I; Rauschmayr, N; Raven, G; Redi, F; Reichert, S; Reid, M M; Dos Reis, A C; Ricciardi, S; Richards, S; Rihl, M; Rinnert, K; Rives Molina, V; Robbe, P; Rodrigues, A B; Rodrigues, E; Rodriguez Lopez, J A; Rodriguez Perez, P; Roiser, S; Romanovsky, V; Romero Vidal, A; Ronayne, J W; Rotondo, M; Rouvinet, J; Ruf, T; Ruiz Valls, P; Saborido Silva, J J; Sagidova, N; Sail, P; Saitta, B; Salustino Guimaraes, V; Sanchez Mayordomo, C; Sanmartin Sedes, B; Santacesaria, R; Santamarina Rios, C; Santimaria, M; Santovetti, E; Sarti, A; Satriano, C; Satta, A; Saunders, D M; Savrina, D; Schiller, M; Schindler, H; Schlupp, M; Schmelling, M; Schmelzer, T; Schmidt, B; Schneider, O; Schopper, A; Schubiger, M; Schune, M-H; Schwemmer, R; Sciascia, B; Sciubba, A; Semennikov, A; Serra, N; Serrano, J; Sestini, L; Seyfert, P; Shapkin, M; Shapoval, I; Shcheglov, Y; Shears, T; Shekhtman, L; Shevchenko, V; Shires, A; Siddi, B G; Silva Coutinho, R; Simi, G; Sirendi, M; Skidmore, N; Skillicorn, I; Skwarnicki, T; Smith, E; Smith, E; Smith, I T; Smith, J; Smith, M; Snoek, H; Sokoloff, M D; Soler, F J P; Soomro, F; Souza, D; Souza De Paula, B; Spaan, B; Spradlin, P; Sridharan, S; Stagni, F; Stahl, M; Stahl, S; Stefkova, S; Steinkamp, O; Stenyakin, O; Stevenson, S; Stoica, S; Stone, S; Storaci, B; Stracka, S; Straticiuc, M; Straumann, U; Sun, L; Sutcliffe, W; Swientek, K; Swientek, S; Syropoulos, V; Szczekowski, M; Szczypka, P; Szumlak, T; T'Jampens, S; Tayduganov, A; Tekampe, T; Teklishyn, M; Tellarini, G; Teubert, F; Thomas, C; Thomas, E; van Tilburg, J; Tisserand, V; Tobin, M; Todd, J; Tolk, S; Tomassetti, L; Tonelli, D; Topp-Joergensen, S; Torr, N; Tournefier, E; Tourneur, S; Trabelsi, K; Tran, M T; Tresch, M; Trisovic, A; Tsaregorodtsev, A; Tsopelas, P; Tuning, N; Ukleja, A; Ustyuzhanin, A; Uwer, U; Vacca, C; Vagnoni, V; Valenti, G; Vallier, A; Vazquez Gomez, R; Vazquez Regueiro, P; Vázquez Sierra, C; Vecchi, S; Velthuis, J J; Veltri, M; Veneziano, G; Vesterinen, M; Viaud, B; Vieira, D; Vieites Diaz, M; Vilasis-Cardona, X; Vollhardt, A; Volyanskyy, D; Voong, D; Vorobyev, A; Vorobyev, V; Voß, C; de Vries, J A; Waldi, R; Wallace, C; Wallace, R; Walsh, J; Wandernoth, S; Wang, J; Ward, D R; Watson, N K; Websdale, D; Weiden, A; Whitehead, M; Wilkinson, G; Wilkinson, M; Williams, M; Williams, M P; Williams, M; Williams, T; Wilson, F F; Wimberley, J; Wishahi, J; Wislicki, W; Witek, M; Wormser, G; Wotton, S A; Wright, S; Wyllie, K; Xie, Y; Xu, Z; Yang, Z; Yu, J; Yuan, X; Yushchenko, O; Zangoli, M; Zavertyaev, M; Zhang, L; Zhang, Y; Zhelezov, A; Zhokhov, A; Zhong, L; Zucchelli, S
2015-08-14
Observations of exotic structures in the J/ψp channel, which we refer to as charmonium-pentaquark states, in Λ_{b}^{0}→J/ψK^{-}p decays are presented. The data sample corresponds to an integrated luminosity of 3 fb^{-1} acquired with the LHCb detector from 7 and 8 TeV pp collisions. An amplitude analysis of the three-body final state reproduces the two-body mass and angular distributions. To obtain a satisfactory fit of the structures seen in the J/ψp mass spectrum, it is necessary to include two Breit-Wigner amplitudes that each describe a resonant state. The significance of each of these resonances is more than 9 standard deviations. One has a mass of 4380±8±29 MeV and a width of 205±18±86 MeV, while the second is narrower, with a mass of 4449.8±1.7±2.5 MeV and a width of 39±5±19 MeV. The preferred J^{P} assignments are of opposite parity, with one state having spin 3/2 and the other 5/2.
Specific heat of FeSe: Two gaps with different anisotropy in superconducting state
NASA Astrophysics Data System (ADS)
Muratov, A. V.; Sadakov, A. V.; Gavrilkin, S. Yu.; Prishchepa, A. R.; Epifanova, G. S.; Chareev, D. A.; Pudalov, V. M.
2018-05-01
We present detailed study of specific heat of FeSe single crystals with critical temperature Tc = 8.45 K at 0.4 - 200 K in magnetic fields 0 - 9 T. Analysis of the electronic specific heat at low temperatures shows the coexistence of isotropic s-wave gap and strongly anisotropic extended s-wave gap without nodes. It was found two possibilities of superconducting gap parameters which give equally description of experimental data: (i) two gaps with approximately equal amplitudes and weight contribution to specific heat: isotropic Δ1 = 1.7 meV (2Δ1 /kBTc =4.7) and anisotropic gap with the amplitude Δ2max = 1.8 meV (2 Δ2max /kBTc =4.9 and anisotropy parameter m = 0.85); (ii) two gaps with substantially different values: isotropic large gap Δ1 = 1.65 meV (2Δ1 /kBTc = 4.52) and anisotropic small gap Δ2max = 0.75 meV (2Δ2max /kBTc = 2) with anisotropy parameter m = 0.71 . These results are confirmed by the field behavior of the residual electronic specific heat γr.
Effect of temperature on the spectral properties of InP/ZnS nanocrystals
NASA Astrophysics Data System (ADS)
Savchenko, S. S.; Vokhmintsev, A. S.; Weinstein, I. A.
2018-01-01
Optical absorption (OA) and photoluminescence (PL) spectra of InP/ZnS core/shell nanocrystals with 2.3 nm average size were investigated in the temperature range of 6.5-296 K. Using second derivative spectrophotometry technique energies of the OA transitions at 296 K in quantum dot (QD) solutions and films are evaluated to be E 1 = 2.37, E 2 = 4.10 and E 3 = 4.68 eV. Temperature shifts of the E 1 and E 2 levels are found to result from interaction with effective phonons of 59 and 37 meV energies, respectively. Herewith the 370 meV half-width of the first exciton absorption peak remains constant due to the dominance of inhomogeneous broadening effects caused by QD parameters distribution. Measured PL spectra have a complex structure and can be described in 6.5-296 K range by two independent Gaussian components associated with exciton and defect-related states. In addition, Stokes shift of 320 meV is observed to decrease at T > 200 K. PL thermal quenching analysis in frame of Mott mechanism points to presence of non-radiative relaxation channel with an activation energy of 74 meV.
Gamma rays of 0.3 to 30 MeV from PSR 0531+21
NASA Technical Reports Server (NTRS)
White, R. S.; Sweeney, W.; Tuemer, T.; Zych, A. D.
1985-01-01
Pulsed gamma rays from the Crab Pulsar PSR 0531+21 are reported for energies of 0.3 to 30 MeV. The observations were carried out with the UCR gamma ray double Compton scatter telescope launched on a balloon from Palestine, Texas at 4.5 GV, at 2200 LT, September 29, 1978. Two 8 hr observations of the pulsar were made, the first starting at 0700 UT (0200 LT) September 30 just after reaching float altitude of 4.5 g/sq cm. Analysis of the total gamma ray flux from the Crab Nebula plus pulsar using telescope vertical cell pairs was published previously. The results presented supersede the preliminary ones. The double scatter mode of the UCR telescope measures the energy of each incident gamma ray from 1 to 30 MeV and its incident angle to a ring on the sky. The time of arrival is measured to 0.05 ms. The direction of the source is obtained from overlapping rings on the sky. The count rate of the first scatter above a threshold of 0.3 MeV is recorded every 5.12 ms. The Crab Pulsar parameters were determined from six topocentric arrival times of optical pulses.
Hall mobility and photoconductivity in TlGaSeS crystals
NASA Astrophysics Data System (ADS)
Qasrawi, A. F.; Gasanly, N. M.
2013-01-01
In this work, the fundamental properties of the TlGaSeS single crystals are investigated by means of temperature dependent electrical resistivity and Hall mobility. The crystal photo-responsibility as function of illumination intensity and temperature is also tested in the temperature range of 350-160 K. The study allowed the determination of acceptor centers as 230 and 450 meV below and above 260 K, and recombination centers as 181, 363, and 10 meV at low, moderate, and high temperatures, respectively. While the temperature-dependent Hall mobility behaved abnormally, the photoconductivity analysis reflected an illumination intensity dependent recombination center. Namely, the recombination center increased from 10 to 90 meV as the light intensity increased from 27.9 to 76.7 mW cm-2, respectively. That strange behavior was attributed to the temporary shift in Fermi level caused by photoexcitation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sanetullaev, A.; Kanungo, R.; Tanaka, J.
2016-03-02
Here, the first measurement of the one-neutron transfer reaction 11Li(p,d) 10Li performed using the IRIS facility at TRIUMF with a 5.7A MeV 11Li beam interacting with a solid H 2 target is reported. The 10Li residue was populated strongly as a resonance peak with energy E r = 0.62 ± 0.04 MeV having a total width Γ = 0.33 ± 0.07 MeV. The angular distribution of this resonance is characterized by neutron occupying the 1p 1/2 orbital. A DWBA analysis yields a spectroscopic factor of 0.67 ± 0.12 for p 1/2 removal strength from the ground state of 11Li tomore » the region of the peak.« less
Geomagnetically trapped light isotopes observed with the detector NINA
NASA Astrophysics Data System (ADS)
Bakaldin, A.; Galper, A.; Koldashov, S.; Korotkov, M.; Leonov, A.; Mikhailov, V.; Murashov, A.; Voronov, S.; Bidoli, V.; Casolino, M.; De Pascale, M.; Furano, G.; Iannucci, A.; Morselli, A.; Picozza, P.; Sparvoli, R.; Boezio, M.; Bonvicini, V.; Cirami, R.; Vacchi, A.; Zampa, N.; Ambriola, M.; Bellotti, R.; Cafagna, F.; Ciacio, F.; Circella, M.; De Marzo, C.; Adriani, O.; Papini, P.; Spillantini, P.; Straulino, S.; Vannuccini, E.; Ricci, M.; Castellini, G.
2002-08-01
The detector New Instrument for Nuclear Analysis (NINA) aboard the satellite Resurs-01-N4 detected hydrogen and helium isotopes geomagnetically trapped, while crossing the South Atlantic Anomaly. Deuterium and tritium at L shell < 1.2 were unambiguously recognized. The 3He and 4He power law spectra, reconstructed at L shell = 1.2 and B < 0.22 G, have indices equal to 2.30 +/- 0.08 in the energy range 12-50 MeV nucleon-1 and 3.4 +/- 0.2 in 10-30 MeV nucleon-1, respectively. The measured 3He/4He ratio and the reconstructed deuterium profile as a function of L shell bring one to the conclusion that the main source of radiation belt light isotopes at Resurs altitudes (~800 km) and for energy greater than 10 MeV nucleon-1 is the interaction of trapped protons with residual atmospheric helium.
Tooth enamel dosimetric response to 2.8 MeV neutrons
NASA Astrophysics Data System (ADS)
Fattibene, P.; Angelone, M.; Pillon, M.; De Coste, V.
2003-03-01
Tooth enamel dosimetry, based on electron paramagnetic resonance (EPR) spectroscopy, is recognized as a powerful method for individual retrospective dose assessment. The method is mainly used for individual dose reconstruction in the epidemiological studies aimed at the radiation risk analysis. The study of the sensitivity of tooth enamel as a function of radiation quality is one of the main goals of the research in this field. In the present work, tooth enamel dose response in a monoenergetic neutron flux of 2.8 MeV, generated by the D-D reaction, was studied for in air and in phantom irradiations of enamel samples and of whole teeth. EPR measurements were complemented by Monte Carlo calculation and by gamma dose discrimination obtained with thermoluminescent and Geiger-Muller tube measurements. The 2.8 MeV neutrons to 60Co relative sensitivity was 0.33±0.08.
Magnifying lens for 800 MeV proton radiography.
Merrill, F E; Campos, E; Espinoza, C; Hogan, G; Hollander, B; Lopez, J; Mariam, F G; Morley, D; Morris, C L; Murray, M; Saunders, A; Schwartz, C; Thompson, T N
2011-10-01
This article describes the design and performance of a magnifying magnetic-lens system designed, built, and commissioned at the Los Alamos National Laboratory (LANL) for 800 MeV flash proton radiography. The technique of flash proton radiography has been developed at LANL to study material properties under dynamic loading conditions through the analysis of time sequences of proton radiographs. The requirements of this growing experimental program have resulted in the need for improvements in spatial radiographic resolution. To meet these needs, a new magnetic lens system, consisting of four permanent magnet quadrupoles, has been developed. This new lens system was designed to reduce the second order chromatic aberrations, the dominant source of image blur in 800 MeV proton radiography, as well as magnifying the image to reduce the blur contribution from the detector and camera systems. The recently commissioned lens system performed as designed, providing nearly a factor of three improvement in radiographic resolution.
Magnifying lens for 800 MeV proton radiography
NASA Astrophysics Data System (ADS)
Merrill, F. E.; Campos, E.; Espinoza, C.; Hogan, G.; Hollander, B.; Lopez, J.; Mariam, F. G.; Morley, D.; Morris, C. L.; Murray, M.; Saunders, A.; Schwartz, C.; Thompson, T. N.
2011-10-01
This article describes the design and performance of a magnifying magnetic-lens system designed, built, and commissioned at the Los Alamos National Laboratory (LANL) for 800 MeV flash proton radiography. The technique of flash proton radiography has been developed at LANL to study material properties under dynamic loading conditions through the analysis of time sequences of proton radiographs. The requirements of this growing experimental program have resulted in the need for improvements in spatial radiographic resolution. To meet these needs, a new magnetic lens system, consisting of four permanent magnet quadrupoles, has been developed. This new lens system was designed to reduce the second order chromatic aberrations, the dominant source of image blur in 800 MeV proton radiography, as well as magnifying the image to reduce the blur contribution from the detector and camera systems. The recently commissioned lens system performed as designed, providing nearly a factor of three improvement in radiographic resolution.
First direct detection limits on sub-GeV dark matter from XENON10.
Essig, Rouven; Manalaysay, Aaron; Mardon, Jeremy; Sorensen, Peter; Volansky, Tomer
2012-07-13
The first direct detection limits on dark matter in the MeV to GeV mass range are presented, using XENON10 data. Such light dark matter can scatter with electrons, causing ionization of atoms in a detector target material and leading to single- or few-electron events. We use 15 kg day of data acquired in 2006 to set limits on the dark-matter-electron scattering cross section. The strongest bound is obtained at 100 MeV where σ(e)<3×10(-38) cm2 at 90% C.L., while dark-matter masses between 20 MeV and 1 GeV are bounded by σ(e)<10(-37) cm2 at 90% C.L. This analysis provides a first proof of principle that direct detection experiments can be sensitive to dark-matter candidates with masses well below the GeV scale.
Fast neutron detection with a segmented spectrometer
NASA Astrophysics Data System (ADS)
Langford, T. J.; Bass, C. D.; Beise, E. J.; Breuer, H.; Erwin, D. K.; Heimbach, C. R.; Nico, J. S.
2015-01-01
A fast neutron spectrometer consisting of segmented plastic scintillator and 3He proportional counters was constructed for the measurement of neutrons in the energy range 1-200 MeV. We discuss its design, principles of operation, and the method of analysis. The detector is capable of observing very low neutron fluxes in the presence of ambient gamma background and does not require scintillator pulse-shape discrimination. The spectrometer was characterized for its energy response in fast neutron fields of 2.5 MeV and 14 MeV, and the results are compared with Monte Carlo simulations. Measurements of the fast neutron flux and energy response at 120 m above sea-level (39.130°N, 77.218°W) and at a depth of 560 m in a limestone mine are presented. Finally, the design of a spectrometer with improved sensitivity and energy resolution is discussed.
Low Energy 8 B Solar Neutrinos with the Wideband Intelligent Trigger at Super-Kamiokande
NASA Astrophysics Data System (ADS)
Elnimr, Muhammad;
2017-09-01
The water Cherenkov experiment Super-Kamiokande (SK) has accumulated a sample of ˜ 90k solar neutrino data in the past two decades. Currently, the detector measures recoil electrons from solar 8 B neutrino-electron scattering above a kinetic energy of ˜ 3.5 MeV, limited by the capacity of the software trigger, although electrons as low as 2.5 MeV can be reconstructed. The next frontier for the low energy program at Super-K is the current operation of the Wideband Intelligent Trigger (WIT) to push the trigger threshold to the event reconstruction limit of 2.5 MeV. This opens up the possibility to explore the lower energy edge of the Mikheyev-Smirnov-Wolfenstein (MSW) effect in the sun. In this work we will present the prelimiary analysis of the accumlated WIT data taken so far as well as future prospects.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rebai, M., E-mail: marica.rebai@mib.infn.it; Nocente, M.; Rigamonti, D.
2016-11-15
A Single-crystal Diamond (SD) detector prototype was installed at Joint European Torus (JET) in 2013 and the achieved results have shown its spectroscopic capability of measuring 2.5 MeV neutrons from deuterium plasmas. This paper presents measurements of the SD response function to monoenergetic neutrons, which is a key point for the development of a neutron spectrometer based on SDs and compares them with Monte Carlo simulations. The analysis procedure allows for a good reconstruction of the experimental results. The good pulse height energy resolution (equivalent FWHM of 80 keV at 2.5 MeV), gain stability, insensitivity to magnetic field, and compactmore » size make SDs attractive as compact neutron spectrometers of high flux deuterium plasmas, such as for instance those needed for the ITER neutron camera.« less
The First FERMI-LAT Gamma-Ray Burst Catalog
NASA Technical Reports Server (NTRS)
Ackermann, M.; Ajello, M.; Asano, K.; Axelsson, M.; Baldini, L.; Ballet, J.; Barbiellini, G.; Bastieri, D.; Bechtol, K.; Bellazzini, R.;
2013-01-01
In three years of observations since the beginning of nominal science operations in 2008 August, the Large Area Telescope (LAT) on board the Fermi Gamma-Ray Space Telescope has observed high-energy great than (20 MeV) gamma-ray emission from 35 gamma-ray bursts (GRBs). Among these, 28 GRBs have been detected above 100 MeV and 7 GRBs above approximately 20 MeV. The first Fermi-LAT catalog of GRBs is a compilation of these detections and provides a systematic study of high-energy emission from GRBs for the first time. To generate the catalog, we examined 733 GRBs detected by the Gamma-Ray Burst Monitor (GBM) on Fermi and processed each of them using the same analysis sequence. Details of the methodology followed by the LAT collaboration for the GRB analysis are provided. We summarize the temporal and spectral properties of the LAT-detected GRBs. We also discuss characteristics of LAT-detected emission such as its delayed onset and longer duration compared with emission detected by the GBM, its power-law temporal decay at late times, and the fact that it is dominated by a power-law spectral component that appears in addition to the usual Band model.
The first Fermi-LAT Gamma-Ray burst catalog
Ackermann, M.; Ajello, M.; Asano, K.; ...
2013-10-23
In three years of observations since the beginning of nominal science operations in 2008 August, the Large Area Telescope (LAT) on board the Fermi Gamma-Ray Space Telescope has observed high-energy (gsim 20 MeV) γ-ray emission from 35 gamma-ray bursts (GRBs). Among these, 28 GRBs have been detected above 100 MeV and 7 GRBs above ~20 MeV. The first Fermi-LAT catalog of GRBs is a compilation of these detections and provides a systematic study of high-energy emission from GRBs for the first time. To generate the catalog, we examined 733 GRBs detected by the Gamma-Ray Burst Monitor (GBM) on Fermi andmore » processed each of them using the same analysis sequence. Details of the methodology followed by the LAT collaboration for the GRB analysis are provided. Here, we summarize the temporal and spectral properties of the LAT-detected GRBs. We also discuss characteristics of LAT-detected emission such as its delayed onset and longer duration compared with emission detected by the GBM, its power-law temporal decay at late times, and the fact that it is dominated by a power-law spectral component that appears in addition to the usual Band model.« less
METHODS AND ANALYSES FOR IMPLEMENTING NATURAL ATTENUATION PROTOCOLS
Technical protocols for evaluating natural attenuation at petroleum hydrocarbon and chlorinated solvent contaminated sites specify the analysis of electron acceptors and metabolic by-products for identifying and quantifying natural attenuation processes. However, these protocols ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Petrov, M.P.; Bell, R.; Budny, R.V.
1998-07-01
This paper presents studies of ICRF-driven H+ minority ions in TFTR (Tokamak Fusion Test Reator) deuterium plasmas using primarily passive Ho flux detection in the energy range of 0.2-1.0 MeV with some corroborating active (lithium pellet charge exchange) measurements. It is shown that in the passive mode the main donors for the neutralization of H+ ions in this energy range are C5+ ions. The measured effective H+ tail temperatures range from 0.15 MeV at an ICRF power of 2 MW to 0.35 MeV at 6 MW. Analysis of the ICRF-driven H+ ion energy balance has been performed on the basismore » of the dependence of effective H+ temperatures on the plasma parameters. The analysis showed that H+ confinement times are comparable with their slowing-down times and tended to decrease with increasing ICRF power. Radial redistribution of ICRF-driven H+ ions was detected when giant sawtooth crashes occurred during the ICRF heating. The redistribution affected ions with energy below 0.7-0.8 MeV. The sawtooth crashes displace H+ ions outward along the plasma major radius into the stochastic ripple diffusion domain were those ions are lost in about 10 milliseconds. These observations are consistent with the model of the redistribution of energetic particles developed previously to explain the results of deuterium-tritium alpha-particle redistribution due to sawteeth observed in TFTR. The experimental data are also consistent with ORBIT code simulations of H+ stochastic ripple diffusion losses.« less
A study of beryllium and beryllium-lithium complexes in single crystal silicon
NASA Technical Reports Server (NTRS)
Crouch, R. K.; Robertson, J. B.; Gilmer, T. E., Jr.
1972-01-01
When beryllium is thermally diffused into silicon, it gives rise to acceptor levels 191 MeV and 145 meV above the valence band. Quenching and annealing studies indicate that the 145-MeV level is due to a more complex beryllium configuration than the 191-MeV level. When lithium is thermally diffused into a beryllium-doped silicon sample, it produces two acceptor levels at 106 MeV and 81 MeV. Quenching and annealing studies indicate that these levels are due to lithium forming a complex with the defects responsible for the 191-MeV and 145-MeV beryllium levels, respectively. Electrical measurements imply that the lithium impurity ions are physically close to the beryllium impurity atoms. The ground state of the 106-MeV beryllium level is split into two levels, presumably by internal strains. Tentative models are proposed.
NASA Astrophysics Data System (ADS)
Pastuovic, Z.; Siegele, R.; Cohen, D. D.; Mann, M.; Ionescu, M.; Button, D.; Long, S.
2017-08-01
The Centre for Accelerator Science facility at ANSTO has been expanded with the new NEC 6 MV ;SIRIUS; accelerator system in 2015. In this paper we present a detailed description of the new nuclear microprobe-Confocal Heavy Ion Micro-Probe (CHIMP) together with results of the microprobe resolution testing and the elemental analysis performed on typical samples of mineral ore deposits and hyper-accumulating plants regularly measured at ANSTO. The CHIMP focusing and scanning systems are based on the OM-150 Oxford quadrupole triplet and the OM-26 separated scan-coil doublet configurations. A maximum ion rigidity of 38.9 amu-MeV was determined for the following nuclear microprobe configuration: the distance from object aperture to collimating slits of 5890 mm, the working distance of 165 mm and the lens bore diameter of 11 mm. The overall distance from the object to the image plane is 7138 mm. The CHIMP beamline has been tested with the 3 MeV H+ and 6 MeV He2+ ion beams. The settings of the object and collimating apertures have been optimized using the WinTRAX simulation code for calculation of the optimum acceptance settings in order to obtain the highest possible ion current for beam spot sizes of 1 μm and 5 μm. For optimized aperture settings of the CHIMP the beam brightness was measured to be ∼0.9 pA μm-2 mrad-2 for 3 MeV H+ ions, while the brightness of ∼0.4 pA μm-2 mrad-2 was measured for 6 MeV He2+ ions. The smallest beam sizes were achieved using a microbeam with reduced particle rate of 1000 Hz passing through the object slit apertures several micrometers wide. Under these conditions a spatial resolution of ∼0.6 μm × 1.5 μm for 3 MeV H+ and ∼1.8 μm × 1.8 μm for 6 MeV He2+ microbeams in horizontal (and vertical) dimension has been achieved. The beam sizes were verified using STIM imaging on 2000 and 1000 mesh Cu electron microscope grids.
NASA Technical Reports Server (NTRS)
Singleterry, Robert C., Jr.; Walker, Steven A.; Clowdsley, Martha S.
2016-01-01
The mathematical models for Solar Particle Event (SPE) high energy tails are constructed with several di erent algorithms. Since limited measured data exist above energies around 400 MeV, this paper arbitrarily de nes the high energy tail as any proton with an energy above 400 MeV. In order to better understand the importance of accurately modeling the high energy tail for SPE spectra, the contribution to astronaut whole body e ective dose equivalent of the high energy portions of three di erent SPE models has been evaluated. To ensure completeness of this analysis, simple and complex geometries were used. This analysis showed that the high energy tail of certain SPEs can be relevant to astronaut exposure and hence safety. Therefore, models of high energy tails for SPEs should be well analyzed and based on data if possible.
Delpeut, Sebastien; Sisson, Gary; Black, Karen M.
2017-01-01
ABSTRACT Measles virus (MeV) is a member of the family Paramixoviridae that causes a highly contagious respiratory disease but has emerged as a promising oncolytic platform. Previous studies of MeV entry focused on the identification of cellular receptors. However, the endocytic and trafficking pathways utilized during MeV entry remain poorly described. The contribution of each endocytic pathway has been examined in cells that express the MeV receptors SLAM (signaling lymphocyte-activating molecule) and PVRL4 (poliovirus receptor-like 4) (nectin-4). Recombinant MeVs expressing either firefly luciferase or green fluorescent protein together with a variety of inhibitors were used. The results showed that MeV uptake was dynamin independent in the Vero.hPVRL4, Vero.hSLAM, and PVRL4-positive MCF7 breast cancer cell lines. However, MeV infection was blocked by 5-(N-ethyl-N-propyl)amiloride (EIPA), the hallmark inhibitor of macropinocytosis, as well as inhibitors of actin polymerization. By using phalloidin staining, MeV entry was shown to induce actin rearrangements and the formation of membrane ruffles accompanied by transient elevated fluid uptake. Small interfering RNA (siRNA) knockdown of p21-activated kinase 1 (PAK1) demonstrated that MeV enters both Vero.hPVRL4 and Vero.hSLAM cells in a PAK1-independent manner using a macropinocytosis-like pathway. In contrast, MeV entry into MCF7 human breast cancer cells relied upon Rac1 and its effector PAK1 through a PVRL4-mediated macropinocytosis pathway. MeV entry into DLD-1 colon and HTB-20 breast cancer cells also appeared to use the same pathway. Overall, these findings provide new insight into the life cycle of MeV, which could lead to therapies that block virus entry or methods that improve the uptake of MeV by cancer cells during oncolytic therapy. IMPORTANCE In the past decades, measles virus (MeV) has emerged as a promising oncolytic platform. Previous studies concerning MeV entry focused mainly on the identification of putative receptors for MeV. Nectin-4 (PVRL4) was recently identified as the epithelial cell receptor for MeV. However, the specific endocytic and trafficking pathways utilized during MeV infections are poorly documented. In this study, we demonstrated that MeV enters host cells via a dynamin-independent and actin-dependent endocytic pathway. Moreover, we show that MeV gains entry into MCF7, DLD-1, and HTB-20 cancer cells through a PVRL4-mediated macropinocytosis pathway and identified the typical cellular GTPase and kinase involved. Our findings provide new insight into the life cycle of MeV, which may lead to the development of therapies that block the entry of the virus into the host cell or alternatively promote the uptake of oncolytic MeV into cancer cells. PMID:28250131
Determining attenuation properties of interfering fast and slow ultrasonic waves in cancellous bone.
Nelson, Amber M; Hoffman, Joseph J; Anderson, Christian C; Holland, Mark R; Nagatani, Yoshiki; Mizuno, Katsunori; Matsukawa, Mami; Miller, James G
2011-10-01
Previous studies have shown that interference between fast waves and slow waves can lead to observed negative dispersion in cancellous bone. In this study, the effects of overlapping fast and slow waves on measurements of the apparent attenuation as a function of propagation distance are investigated along with methods of analysis used to determine the attenuation properties. Two methods are applied to simulated data that were generated based on experimentally acquired signals taken from a bovine specimen. The first method uses a time-domain approach that was dictated by constraints imposed by the partial overlap of fast and slow waves. The second method uses a frequency-domain log-spectral subtraction technique on the separated fast and slow waves. Applying the time-domain analysis to the broadband data yields apparent attenuation behavior that is larger in the early stages of propagation and decreases as the wave travels deeper. In contrast, performing frequency-domain analysis on the separated fast waves and slow waves results in attenuation coefficients that are independent of propagation distance. Results suggest that features arising from the analysis of overlapping two-mode data may represent an alternate explanation for the previously reported apparent dependence on propagation distance of the attenuation coefficient of cancellous bone. © 2011 Acoustical Society of America
Determining attenuation properties of interfering fast and slow ultrasonic waves in cancellous bone
Nelson, Amber M.; Hoffman, Joseph J.; Anderson, Christian C.; Holland, Mark R.; Nagatani, Yoshiki; Mizuno, Katsunori; Matsukawa, Mami; Miller, James G.
2011-01-01
Previous studies have shown that interference between fast waves and slow waves can lead to observed negative dispersion in cancellous bone. In this study, the effects of overlapping fast and slow waves on measurements of the apparent attenuation as a function of propagation distance are investigated along with methods of analysis used to determine the attenuation properties. Two methods are applied to simulated data that were generated based on experimentally acquired signals taken from a bovine specimen. The first method uses a time-domain approach that was dictated by constraints imposed by the partial overlap of fast and slow waves. The second method uses a frequency-domain log-spectral subtraction technique on the separated fast and slow waves. Applying the time-domain analysis to the broadband data yields apparent attenuation behavior that is larger in the early stages of propagation and decreases as the wave travels deeper. In contrast, performing frequency-domain analysis on the separated fast waves and slow waves results in attenuation coefficients that are independent of propagation distance. Results suggest that features arising from the analysis of overlapping two-mode data may represent an alternate explanation for the previously reported apparent dependence on propagation distance of the attenuation coefficient of cancellous bone. PMID:21973378
Single crystal to polycrystal neutron transmission simulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dessieux, Luc Lucius; Stoica, Alexandru Dan; Bingham, Philip R.
A collection of routines for calculation of the total cross section that determines the attenuation of neutrons by crystalline solids is presented. The total cross section is calculated semi-empirically as a function of crystal structure, neutron energy, temperature, and crystal orientation. The semi-empirical formula includes the contribution of parasitic Bragg scattering to the total cross section using both the crystal’s mosaic spread value and its orientation with respect to the neutron beam direction as parameters. These routines allow users to enter a distribution of crystal orientations for calculation of total cross sections of user defined powder or pseudo powder distributions,more » which enables simulation of non-uniformities such as texture and strain. In conclusion, the spectra for neutron transmission simulations in the neutron thermal energy range (2 meV–100 meV) are presented for single crystal and polycrystal samples and compared to measurements.« less
Generation of first hard X-ray pulse at Tsinghua Thomson Scattering X-ray Source.
Du, Yingchao; Yan, Lixin; Hua, Jianfei; Du, Qiang; Zhang, Zhen; Li, Renkai; Qian, Houjun; Huang, Wenhui; Chen, Huaibi; Tang, Chuanxiang
2013-05-01
Tsinghua Thomson Scattering X-ray Source (TTX) is the first-of-its-kind dedicated hard X-ray source in China based on the Thomson scattering between a terawatt ultrashort laser and relativistic electron beams. In this paper, we report the experimental generation and characterization of the first hard X-ray pulses (51.7 keV) via head-on collision of an 800 nm laser and 46.7 MeV electron beams. The measured yield is 1.0 × 10(6) per pulse with an electron bunch charge of 200 pC and laser pulse energy of 300 mJ. The angular intensity distribution and energy spectra of the X-ray pulse are measured with an electron-multiplying charge-coupled device using a CsI scintillator and silicon attenuators. These measurements agree well with theoretical and simulation predictions. An imaging test using the X-ray pulse at the TTX is also presented.
Single crystal to polycrystal neutron transmission simulation
Dessieux, Luc Lucius; Stoica, Alexandru Dan; Bingham, Philip R.
2018-02-02
A collection of routines for calculation of the total cross section that determines the attenuation of neutrons by crystalline solids is presented. The total cross section is calculated semi-empirically as a function of crystal structure, neutron energy, temperature, and crystal orientation. The semi-empirical formula includes the contribution of parasitic Bragg scattering to the total cross section using both the crystal’s mosaic spread value and its orientation with respect to the neutron beam direction as parameters. These routines allow users to enter a distribution of crystal orientations for calculation of total cross sections of user defined powder or pseudo powder distributions,more » which enables simulation of non-uniformities such as texture and strain. In conclusion, the spectra for neutron transmission simulations in the neutron thermal energy range (2 meV–100 meV) are presented for single crystal and polycrystal samples and compared to measurements.« less
High spin structure and intruder configurations in 31P
NASA Astrophysics Data System (ADS)
Ionescu-Bujor, M.; Iordachescu, A.; Napoli, D. R.; Lenzi, S. M.; Mărginean, N.; Otsuka, T.; Utsuno, Y.; Ribas, R. V.; Axiotis, M.; Bazzacco, D.; Bizzeti-Sona, A. M.; Bizzeti, P. G.; Brandolini, F.; Bucurescu, D.; Cardona, M. A.; De Angelis, G.; De Poli, M.; Della Vedova, F.; Farnea, E.; Gadea, A.; Hojman, D.; Kalfas, C. A.; Kröll, Th.; Lunardi, S.; Martínez, T.; Mason, P.; Pavan, P.; Quintana, B.; Alvarez, C. Rossi; Ur, C. A.; Vlastou, R.; Zilio, S.
2006-02-01
The nucleus 31P has been studied in the 24Mg(16O,2αp) reaction with a 70-MeV 16O beam. A complex level scheme extended up to spins 17/2+ and 15/2-, on positive and negative parity, respectively, has been established. Lifetimes for the new states have been investigated by the Doppler shift attenuation method. Two shell-model calculations have been performed to describe the experimental data, one by using the code ANTOINE in a valence space restricted to the sd shell, and the other by applying the Monte Carlo shell model in a valence space including the sd-fp shells. The latter calculation indicates that intruder excitations, involving the promotion of a T=0 proton-neutron pair to the fp shell, play a dominant role in the structure of the positive-parity high-spin states of 31P.
Systematic R -matrix analysis of the 13C(p ,γ )14N capture reaction
NASA Astrophysics Data System (ADS)
Chakraborty, Suprita; deBoer, Richard; Mukherjee, Avijit; Roy, Subinit
2015-04-01
Background: The proton capture reaction 13C(p ,γ )14N is an important reaction in the CNO cycle during hydrogen burning in stars with mass greater than the mass of the Sun. It also occurs in astrophysical sites such as red giant stars: the asymptotic giant branch (AGB) stars. The low energy astrophysical S factor of this reaction is dominated by a resonance state at an excitation energy of around 8.06 MeV (Jπ=1-,T =1 ) in 14N. The other significant contributions come from the low energy tail of the broad resonance with Jπ=0-,T =1 at an excitation of 8.78 MeV and the direct capture process. Purpose: Measurements of the low energy astrophysical S factor of the radiative capture reaction 13C(p ,γ )14N reported extrapolated values of S (0 ) that differ by about 30 % . Subsequent R -matrix analysis and potential model calculations also yielded significantly different values for S (0 ) . The present work intends to look into the discrepancy through a detailed R -matrix analysis with emphasis on the associated uncertainties. Method: A systematic reanalysis of the available decay data following the capture to the Jπ=1-,T =1 resonance state of 14N around 8.06 MeV excitation had been performed within the framework of the R -matrix method. A simultaneous analysis of the 13C(p ,p0 ) data, measured over a similar energy range, was carried out with the capture data. The data for the ground state decay of the broad resonance state (Jπ=0-,T =1 ) around 8.78 MeV excitations was included as well. The external capture model along with the background poles to simulate the internal capture contribution were used to estimate the direct capture contribution. The asymptotic normalization constants (ANCs) for all states were extracted from the capture data. The multichannel, multilevel R -matrix code azure2 was used for the calculation. Results: The values of the astrophysical S factor at zero relative energy, resulting from the present analysis, are found to be consistent within the error bars for the two sets of capture data used. However, it is found from the fits to the elastic scattering data that the position of the Jπ=1-,T =1 resonance state is uncertain by about 0.6 keV, preferring an excitation energy value of 8.062 MeV. Also the extracted ANC values for the states of 14N corroborate the values from the transfer reaction studies. The reaction rates from the present calculation are about 10 -15 % lower than the values of the NACRE II compilation but compare well with those from NACRE I. Conclusion: The precise energy of the Jπ=1-,T =1 resonance level around 8.06 MeV in 14N must be determined. Further measurements around and below 100 keV with precision are necessary to reduce the uncertainty in the S -factor value at zero relative energy.
NASA Astrophysics Data System (ADS)
Weatherill, Graeme; Burton, Paul W.
2010-09-01
The Aegean is the most seismically active and tectonically complex region in Europe. Damaging earthquakes have occurred here throughout recorded history, often resulting in considerable loss of life. The Monte Carlo method of probabilistic seismic hazard analysis (PSHA) is used to determine the level of ground motion likely to be exceeded in a given time period. Multiple random simulations of seismicity are generated to calculate, directly, the ground motion for a given site. Within the seismic hazard analysis we explore the impact of different seismic source models, incorporating both uniform zones and distributed seismicity. A new, simplified, seismic source model, derived from seismotectonic interpretation, is presented for the Aegean region. This is combined into the epistemic uncertainty analysis alongside existing source models for the region, and models derived by a K-means cluster analysis approach. Seismic source models derived using the K-means approach offer a degree of objectivity and reproducibility into the otherwise subjective approach of delineating seismic sources using expert judgment. Similar review and analysis is undertaken for the selection of peak ground acceleration (PGA) attenuation models, incorporating into the epistemic analysis Greek-specific models, European models and a Next Generation Attenuation model. Hazard maps for PGA on a "rock" site with a 10% probability of being exceeded in 50 years are produced and different source and attenuation models are compared. These indicate that Greek-specific attenuation models, with their smaller aleatory variability terms, produce lower PGA hazard, whilst recent European models and Next Generation Attenuation (NGA) model produce similar results. The Monte Carlo method is extended further to assimilate epistemic uncertainty into the hazard calculation, thus integrating across several appropriate source and PGA attenuation models. Site condition and fault-type are also integrated into the hazard mapping calculations. These hazard maps are in general agreement with previous maps for the Aegean, recognising the highest hazard in the Ionian Islands, Gulf of Corinth and Hellenic Arc. Peak Ground Accelerations for some sites in these regions reach as high as 500-600 cm s -2 using European/NGA attenuation models, and 400-500 cm s -2 using Greek attenuation models.
Govindan, R B; Kota, Srinivas; Al-Shargabi, Tareq; Massaro, An N; Chang, Taeun; du Plessis, Adre
2016-09-01
Electroencephalogram (EEG) signals are often contaminated by the electrocardiogram (ECG) interference, which affects quantitative characterization of EEG. We propose null-coherence, a frequency-based approach, to attenuate the ECG interference in EEG using simultaneously recorded ECG as a reference signal. After validating the proposed approach using numerically simulated data, we apply this approach to EEG recorded from six newborns receiving therapeutic hypothermia for neonatal encephalopathy. We compare our approach with an independent component analysis (ICA), a previously proposed approach to attenuate ECG artifacts in the EEG signal. The power spectrum and the cortico-cortical connectivity of the ECG attenuated EEG was compared against the power spectrum and the cortico-cortical connectivity of the raw EEG. The null-coherence approach attenuated the ECG contamination without leaving any residual of the ECG in the EEG. We show that the null-coherence approach performs better than ICA in attenuating the ECG contamination without enhancing cortico-cortical connectivity. Our analysis suggests that using ICA to remove ECG contamination from the EEG suffers from redistribution problems, whereas the null-coherence approach does not. We show that both the null-coherence and ICA approaches attenuate the ECG contamination. However, the EEG obtained after ICA cleaning displayed higher cortico-cortical connectivity compared with that obtained using the null-coherence approach. This suggests that null-coherence is superior to ICA in attenuating the ECG interference in EEG for cortico-cortical connectivity analysis. Copyright © 2016 Elsevier B.V. All rights reserved.
Dietzel, Erik; Anderson, Danielle E; Castan, Alexandre; von Messling, Veronika; Maisner, Andrea
2011-07-01
In paramyxoviruses, the matrix (M) protein mediates the interaction between the envelope and internal proteins during particle assembly and egress. In measles virus (MeV), M mutations, such as those found in subacute sclerosing panencephalitis (SSPE) strains, and differences in vaccine and wild-type M proteins can affect the strength of interaction with the envelope glycoproteins, assembly efficiency, and spread. However, the contribution of the M protein to the replication and pathogenesis of the closely related canine distemper virus (CDV) has not been characterized. To this end this, we generated a recombinant wild-type CDV carrying a vaccine strain M protein. The recombinant virus retained the parental growth phenotype in VerodogSLAMtag cells, but displayed an increased particle-to-infectivity ratio very similar to that of the vaccine strain, likely due to inefficient H protein incorporation. Even though infectious virus was released only from the apical surface, consistent with the release polarity of the wild-type CDV strain, envelope protein distribution in polarized epithelial cells reproduced the bipolar pattern seen in vaccine strain-infected cells. Most notably, the chimeric virus was completely attenuated in ferrets and caused only a mild and transient leukopenia, indicating that the differences in particle infectivity and envelope protein sorting mediated by the vaccine M protein contribute importantly to vaccine strain attenuation.
Origin of the Strain Sensitivity for an Organic Heptazole Thin-Film and Its Strain Gauge Application
NASA Astrophysics Data System (ADS)
Bae, Heesun; Jeon, Pyo Jin; Park, Ji Hoon; Lee, Kimoon
2018-04-01
The authors report on the origin of the strain sensitivity for an organic C26H16N2 (heptazole) thinfilm and its application for the detection of tensile strain. From the electrical characterization on the thin-film transistor adopting a heptazole channel, heptazole film exhibits p-channel conduction with a relatively low value of field-effect mobility (0.05 cm2/Vs), suggesting a hopping conduction behavior via hole carriers. By analyzing the strain and temperature dependences of the electrical conductivity, we reveal that the electrical conduction for a heptazole thin-film is dominated by the variable range hopping process with quite a large energy separation (224.9 meV) between the localized states under a relatively long attenuation length (10.46 Å). This indicates that a change in the inter-grain spacing that is much larger than the attenuation length is responsible for the reversible modification of electrical conductivity depending on strain for the heptazole film. By utilizing our heptazole thin-film both as a strain sensitive passive resistor and an active semiconducting channel layer, we can achieve a strain gauge device exhibiting reversible endurance for tensile strains up to 2.12%. Consequently, this study advances the understanding of the fundamental strain sensing mechanism in a heptazole thin-film toward finding a promise material with a strain gauge for applications as potential flexible devices and/or wearable electronics.
Analysis of the 0.511 MeV radiation at the OSO-7 satellite. Ph.D. Thesis
NASA Technical Reports Server (NTRS)
Dunphy, P. P.
1974-01-01
Observations of the 0.511 MeV positron annihilation, gamma ray on the OSO-7 satellite are presented. Variables which affect the counting rate are discussed. An upper limit flux of .0076 photons/sq cm/sec is obtained for the quiet sun and a positive solar flux of .063(+ or - .0002) photons/sq cm/sec is obtained for the 3B flare of 4 August 1972. The width of this annihilation line gives an upper limit temperature for the annihilation region of approximately 6 million K. An analysis of the line width and position also shows that the contribution to the line from positronium annihilation is less than 100% at the 99% confidence level. An upper limit is also found for an isotropic cosmic flux.
Up-, down-, strange-, charm-, and bottom-quark masses from four-flavor lattice QCD
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bazavov, A.; Bernard, C.; Brambilla, N.
We calculate the up-, down-, strange-, charm-, and bottom-quark masses using the MILC highly improved staggered-quark ensembles with four flavors of dynamical quarks. We use ensembles at six lattice spacings ranging frommore » $$a\\approx0.15~$$fm to $0.03~$fm and with both physical and unphysical values of the two light and the strange sea-quark masses. We use a new method based on heavy-quark effective theory (HQET) to extract quark masses from heavy-light pseudoscalar meson masses. Combining our analysis with our separate determination of ratios of light-quark masses we present masses of the up, down, strange, charm, and bottom quarks. Our results for the $$\\overline{\\text{MS}}$$-renormalized masses are $$m_u(2~\\text{GeV}) = 2.118(38)~$$MeV, $$m_d(2~\\text{GeV}) = 4.690(54)~$$MeV, $$m_s(2~\\text{GeV}) = 92.52(69)~$$MeV, $$m_c(3~\\text{GeV}) = 984.3(5.6)~$$MeV, and $$m_c(m_c) = 1273(10)~$$MeV, with four active flavors; and $$m_b(m_b) = 4197(14)~$$MeV with five active flavors. We also obtain ratios of quark masses $$m_c/m_s = 11.784(22)$$, $$m_b/m_s = 53.93(12)$$, and $$m_b/m_c = 4.577(8)$$. The result for $$m_c$$ matches the precision of the most precise calculation to date, and the other masses and all quoted ratios are the most precise to date. Moreover, these results are the first with a perturbative accuracy of $$\\alpha_s^4$$. As byproducts of our method, we obtain the matrix elements of HQET operators with dimension 4 and 5: $$\\overline{\\Lambda}_\\text{MRS}=552(30)~$$MeV in the minimal renormalon-subtracted (MRS) scheme, $$\\mu_\\pi^2 = 0.06(22)~\\text{GeV}^2$$, and $$\\mu_G^2(m_b)=0.38(2)~\\text{GeV}^2$$. The MRS scheme [Phys. Rev. D97, 034503 (2018), arXiv:1712.04983 [hep-ph
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhai, Y. John
2016-06-15
Purpose: To obtain an improved precise gamma efficiency calibration curve of HPGe (High Purity Germanium) detector with a new comprehensive approach. Methods: Both of radioactive sources and Monte Carlo simulation (CYLTRAN) are used to determine HPGe gamma efficiency for energy range of 0–8 MeV. The HPGe is a GMX coaxial 280 cm{sup 3} N-type 70% gamma detector. Using Momentum Achromat Recoil Spectrometer (MARS) at the K500 superconducting cyclotron of Texas A&M University, the radioactive nucleus {sup 24} Al was produced and separated. This nucleus has positron decays followed by gamma transitions up to 8 MeV from {sup 24} Mg excitedmore » states which is used to do HPGe efficiency calibration. Results: With {sup 24} Al gamma energy spectrum up to 8MeV, the efficiency for γ ray 7.07 MeV at 4.9 cm distance away from the radioactive source {sup 24} Al was obtained at a value of 0.194(4)%, by carefully considering various factors such as positron annihilation, peak summing effect, beta detector efficiency and internal conversion effect. The Monte Carlo simulation (CYLTRAN) gave a value of 0.189%, which was in agreement with the experimental measurements. Applying to different energy points, then a precise efficiency calibration curve of HPGe detector up to 7.07 MeV at 4.9 cm distance away from the source {sup 24} Al was obtained. Using the same data analysis procedure, the efficiency for the 7.07 MeV gamma ray at 15.1 cm from the source {sup 24} Al was obtained at a value of 0.0387(6)%. MC simulation got a similar value of 0.0395%. This discrepancy led us to assign an uncertainty of 3% to the efficiency at 15.1 cm up to 7.07 MeV. The MC calculations also reproduced the intensity of observed single-and double-escape peaks, providing that the effects of positron annihilation-in-flight were incorporated. Conclusion: The precision improved gamma efficiency calibration curve provides more accurate radiation detection and dose calculation for cancer radiotherapy treatment.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Budzanowski, A.; Grotowski, K.
1962-10-15
Recentiy optical model analysis has been applied to fit the experimental angular distribution data of the elastic scattering of deuterons by nuclei. In view of a considerable dependence of sigma /sub R/ on the shape of the real and imaginary part of the potential at the nuclear surface, it was thought worthwhile to measure both sigma /sub el/ ( theta ) and sigma /sub R/ for 12.8 Mev deuterons on targets of separated Ni/sup 58/ and Ni/sup 60/ isotopes. (W.D.M.)
Elastic alpha-particle resonances as evidence of clustering at high excitation in 40Ca
NASA Astrophysics Data System (ADS)
Norrby, M.; Lönnroth, T.; Goldberg, V. Z.; Rogachev, G. V.; Golovkov, M. S.; Källman, K.-M.; Lattuada, M.; Perov, S. V.; Romano, S.; Skorodumov, B. B.; Tiourin, G. P.; Trzaska, W. H.; Tumino, A.; Vorontsov, A. N.
2011-08-01
The elastic-scattering reaction 36Ar + α was studied using the Thick Target Inverse Kinematics technique. Data were taken at a beam energy of 150 MeV in a reaction chamber filled with 4He gas, corresponding to the excitation region of 12-20 MeV in 40Ca. Using a simplified R -matrix method of analysis energies, widths and spin assignments were obtained for 137 resonances. The structure is discussed within the concept of α-cluster structure in the quasi-continuum of 40Ca and is compared to other nuclei in the same mass region.
Minimum effective volume of mepivacaine for ultrasound-guided supraclavicular block
Song, Jae Gyok; Kang, Bong Jin; Park, Kee Keun
2013-01-01
Background The aim of this study was to estimate the minimum effective volume (MEV) of 1.5% mepivacaine for ultrasound-guided supraclavicular block by placing the needle near the lower trunk of brachial plexus and multiple injections. Methods Thirty patients undergoing forearm and hand surgery received ultrasound-guided supraclavicular block with 1.5% mepivacaine. The initial volume of local anesthetic injected was 24 ml, and local anesthetic volume for the next patient was determined by the response of the previous patient. The next patient received a 3 ml higher volume in the case of the failure of the previous case. If the previous block was successful, the next volume was 3 ml lower. MEV was estimated by the Dixon and Massey up and down method. MEV in 95, 90, and 50% of patients (MEV95, MEV90, and MEV50) were calculated using probit transformation and logistic regression. Results MEV95 of 1.5% mepivacaine was 17 ml (95% confidence interval [CI], 13-42 ml), MEV90 was 15 ml (95% CI, 12-34 ml), and MEV50 was 9 ml (95% CI, 4-12 ml). Twelve patients had a failed block. Three patients received general anesthesia. Nine patients could undergo surgery with sedation only. Only one patient showed hemi-diaphragmatic paresis. Conclusions MEV95 was 17 ml, MEV90 was 15 ml, and MEV50 was 9 ml. However, needle location near the lower trunk of brachial plexus and multiple injections should be performed. PMID:23904937
SU-E-T-146: Beam Energy Spread Estimate Based On Bragg Peak Measurement
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anferov, V; Derenchuk, V; Moore, R
2015-06-15
Purpose: ProNova is installing and commissioning a two room proton therapy system in Knoxville, TN. Beam energy out of the 230MeV cyclotron was measured on Jan 24, 2015. Cyclotron beam was delivered into a Zebra multi layered IC detector calibrated in terms of penetration range in water. The analysis of the measured Bragg peak determines penetration range in water which can be subsequently converted into proton beam energy. We extended this analysis to obtain an estimate of the beam energy spread out of the cyclotron. Methods: Using Monte Carlo simulations we established the correlation between Bragg peak shape parameters (widthmore » at 50% and 80% dose levels, distal falloff) and penetration range for a monoenergetic proton beam. For large uniform field impinging on a small area detector, we observed linear dependence of each Bragg peak parameter on beam penetration range as shown in Figure A. Then we studied how this correlation changes when the shape of Bragg peak is distorted by the beam focusing conditions. As shown in Figure B, small field size or diverging beam cause Bragg peak deformation predominantly in the proximal region. The distal shape of the renormalized Bragg peaks stays nearly constant. This excludes usage of Bragg peak width parameters for energy spread estimates. Results: The measured Bragg peaks had an average distal falloff of 4.86mm, which corresponds to an effective range of 35.5cm for a monoenergetic beam. The 32.7cm measured penetration range is 2.8cm less. Passage of a 230MeV proton beam through a 2.8cm thick slab of water results in a ±0.56MeV energy spread. As a final check, we confirmed agreement between shapes of the measured Bragg peak and one generated by Monte-Carlo code for proton beam with 0.56 MeV energy spread. Conclusion: Proton beam energy spread can be estimated using Bragg peak analysis.« less
The host galaxy and Fermi-LAT counterpart of HESS J1943+213
NASA Astrophysics Data System (ADS)
Peter, D.; Domainko, W.; Sanchez, D. A.; van der Wel, A.; Gässler, W.
2014-11-01
Context. The very-high energy (VHE, E> 100 GeV) gamma-ray sky shows diverse Galactic and extragalactic source populations. For some sources the astrophysical object class could not be identified so far. Aims: The nature (Galactic or extragalactic) of the VHE gamma-ray source HESS J1943+213 is explored. We specifically investigate the proposed near-infrared counterpart 2MASS J19435624+2118233 of HESS J1943+213 and investigate the implications of a physical association. Methods: We present K-band imaging from the 3.5 m CAHA telescope of 2MASS J19435624+2118233. Furthermore, 5 years of Fermi-LAT data were analyzed to search for a high-energy (HE, 100 MeV
BACKWARD ANGLE STRUCTURE IN THE 20Ne+28Si QUASIELASTIC SCATTERING
NASA Astrophysics Data System (ADS)
Sgouros, O.; Soukeras, V.; Pakou, A.; Patronis, N.; Zerva, K.; Keeley, N.; Strojek, I.; Trzcińska, A.; Piasecki, E.; Rusek, K.; Stiliaris, E.; Mazzocco, M.
2013-10-01
New data for the quasielastic scattering of 20Ne from a 28Si target at incident energies of 42.5 MeV and 52.3 MeV and for the 28Si(20Ne, 24Mg)24Mg, 28Si(20Ne, 16O)32S and 28Si(20Ne, 12C)36Ar transfer reactions at 52.3 MeV are reported. Oscillations are observed in the backward angle quasielastic scattering data at 52.3 MeV and the 28Si(20Ne, 12C)36Ar transfer cross-sections are of the same magnitude as those for single-α stripping. Coupled reaction channels (CRC) calculations are unable to describe either the quasielastic or the 28Si(20Ne, 12C)36Ar transfer data assuming a sequential α transfer process with α-particle form factors from the literature. The addition of direct 8Be cluster transfer can provide a reasonable description of both data sets, but only with much larger spectroscopic factors than suggested by simple structure calculations or the large 8Be emission thresholds of 20Ne, 28Si and 36Ar, suggesting that the observed structure is of resonance-like origin. An optical model analysis of the quasielastic scattering data is also reported.
Roecker, Caleb; Bernstein, Adam; Marleau, Peter; ...
2016-11-14
Cosmogenic high-energy neutrons are a ubiquitous, difficult to shield, poorly measured background. Above ground the high-energy neutron energy-dependent flux has been measured, with significantly varying results. Below ground, high-energy neutron fluxes are largely unmeasured. Here we present a reconstruction algorithm to unfold the incident neutron energy-dependent flux measured using the Multiplicity and Recoil Spectrometer (MARS), simulated test cases to verify the algorithm, and provide a new measurement of the above ground high-energy neutron energy-dependent flux with a detailed systematic uncertainty analysis. Uncertainty estimates are provided based upon the measurement statistics, the incident angular distribution, the surrounding environment of the Montemore » Carlo model, and the MARS triggering efficiency. Quantified systematic uncertainty is dominated by the assumed incident neutron angular distribution and surrounding environment of the Monte Carlo model. The energy-dependent neutron flux between 90 MeV and 400 MeV is reported. Between 90 MeV and 250 MeV the MARS results are comparable to previous Bonner sphere measurements. Over the total energy regime measured, the MARS result are located within the span of previous measurements. Lastly, these results demonstrate the feasibility of future below ground measurements with MARS.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roecker, Caleb; Bernstein, Adam; Marleau, Peter
Cosmogenic high-energy neutrons are a ubiquitous, difficult to shield, poorly measured background. Above ground the high-energy neutron energy-dependent flux has been measured, with significantly varying results. Below ground, high-energy neutron fluxes are largely unmeasured. Here we present a reconstruction algorithm to unfold the incident neutron energy-dependent flux measured using the Multiplicity and Recoil Spectrometer (MARS), simulated test cases to verify the algorithm, and provide a new measurement of the above ground high-energy neutron energy-dependent flux with a detailed systematic uncertainty analysis. Uncertainty estimates are provided based upon the measurement statistics, the incident angular distribution, the surrounding environment of the Montemore » Carlo model, and the MARS triggering efficiency. Quantified systematic uncertainty is dominated by the assumed incident neutron angular distribution and surrounding environment of the Monte Carlo model. The energy-dependent neutron flux between 90 MeV and 400 MeV is reported. Between 90 MeV and 250 MeV the MARS results are comparable to previous Bonner sphere measurements. Over the total energy regime measured, the MARS result are located within the span of previous measurements. Lastly, these results demonstrate the feasibility of future below ground measurements with MARS.« less
The 2-MEV model: Constancy of adolescent environmental values within an 8-year time frame
NASA Astrophysics Data System (ADS)
Bogner, F. X.; Johnson, B.; Buxner, S.; Felix, L.
2015-08-01
The 2-MEV model is a widely used tool to monitor children's environmental perception by scoring individual values. Although the scale's validity has been confirmed repeatedly and independently as well as the scale is in usage within more than two dozen language units all over the world, longitudinal properties still need clarification. The purpose of the present study therefore was to validate the 2-MEV scale based on a large data basis of 10,676 children collected over an eight-year period. Cohorts of three different US states contributed to the sample by responding to a paper-and-pencil questionnaire within their pre-test initiatives in the context of field center programs. Since we used only the pre-program 2-MEV scale results (which is before participation in education programs), the data were clearly unspoiled by any follow-up interventions. The purpose of analysis was fourfold: First, to test and confirm the hypothesized factorized structure for the large data set and for the subsample of each of the three states. Second, to analyze the scoring pattern across the eight years' time range for both preservation and utilitarian preferences. Third, to investigate any age effects in the extracted factors. Finally, to extract suitable recommendations for educational implementation efforts.
NASA Astrophysics Data System (ADS)
Hubert, G.; Pazianotto, M. T.; Federico, C. A.
2016-12-01
This paper investigates seasonal cosmic ray-induced neutron variations measured over a long-term period (from 2011 to 2016) in both the high-altitude stations located in medium geomagnetic latitude and Antarctica (Pic-du-Midi and Concordia, respectively). To reinforce analysis, modeling based on ground albedo neutrons simulations of extensive air showers and the solar modulation potential was performed. Because the local environment is well known and stable over time in Antarctica, data were used to validate the modeling approach. A modeled scene representative to the Pic-du-Midi was simulated with GEANT4 for various hydrogen properties (composition, density, and wet level) and snow thickness. The orders of magnitudes of calculated thermal fluence rates are consistent with measurements obtained during summers and winters. These variations are dominant in the thermal domain (i.e., En < 0.5 eV) and lesser degree in epithermal and evaporation domains (i.e., 0.5 eV < En < 0.1 MeV and 0.1 MeV < En < 20 MeV, respectively). Cascade neutron (En > 20 MeV) is weakly impacted. The role of hydrogen content on ground albedo neutron generation was investigated with GEANT4 simulations. These investigations focused to mountain environment; nevertheless, they demonstrate the complexity of the local influences on neutron fluence rates.
Medvedev, Dmitri G; Mausner, Leonard F; Pile, Philip
2015-07-01
This paper reports results of experiments at Brookhaven Linac Isotope Producer (BLIP) aiming to investigate effective production of positron emitting radioisotope (86)Y by the low energy (86)Sr(p,n) reaction. BLIP is a facility at Brookhaven National Laboratory designed for the proton irradiation of the targets for isotope production at high and intermediate proton energies. The proton beam is delivered by the Linear Accelerator (LINAC) whose incident energy is tunable from 200 to 66 MeV in approximately 21 MeV increments. The array was designed to ensure energy degradation from 66 MeV down to less than 20 MeV. Aluminum slabs were used to degrade the proton energy down to the required range. The production yield of (86)Y (1.2+/-0.1 mCi (44.4+/-3.7) MBq/μAh) and ratio of radioisotopic impurities was determined by assaying an aliquot of the irradiated (86)SrCl2 solution by gamma spectroscopy. The analysis of energy dependence of the (86)Y production yield and the ratios of radioisotopic impurities has been used to adjust degrader thickness. Experimental data showed substantial discrepancies in actual energy propagation compared to energy loss calculations. Copyright © 2015 Elsevier Ltd. All rights reserved.
Evaluation of the radiation hazard for ion-beam analysis with MeV external proton beams (X-IBA)
NASA Astrophysics Data System (ADS)
Hofsäss, Hans
2018-07-01
MeV ion beams which are extracted into air or He atmosphere are used in many labs for proton-induced X-ray emission (PIXE), proton induced gamma ray emission (PIGE) or Rutherford backscattering (RBS) to analyze samples which are difficult or impossible to handle in vacuum. When MeV proton beams are extracted into air through thin Kapton foils or nowadays thin silicon nitride membranes, the protons will interact with air, as well as elements present in the analyzed samples. Typically the range of MeV protons in air is several cm, in Helium atmosphere several 10 cm and in human skin around 100 μm. Besides the severe radiation hazard in case of a direct exposure of skin with protons, there are a manifold of nuclear reactions or inelastic proton scattering processes which may cause activation of air and target materials but also prompt radiation. The radiation hazard associated with the direct and scattered beam, nuclear reaction products and radionuclide production in air have been discussed in a publication by Doyle et al. in 1991 which was used as a reference in several later publications. I have reevaluated the radiation hazards for external proton beams with up to 4.5 MeV using proton reaction cross sections taken from the JANIS book of proton induced cross sections. The radionuclide production in air is about 3 orders of magnitude lower compared to values given in the 1991 publication. Radionuclide production as well as generation of prompt alpha, gamma and neutron radiation in target materials for elements up to molybdenum is also evaluated.
Comparison of x-ray cross sections for diagnostic and therapeutic medical physics.
Boone, J M; Chavez, A E
1996-12-01
The purpose of this technical report is to make available an up-to-date source of attenuation coefficient data to the medical physics community, and to compare these data with other more familiar sources. Data files from Lawrence Livermore National Laboratory (in Livermore, CA) were truncated to match the needs of the medical physics community, and an interpolation routine was written to calculate a continuous set of cross sections spanning energies from 1 keV to 50 MeV. Coefficient data are available for elements Z = 1 through Z = 100. Values for mass attenuation coefficients, mass-energy-transfer coefficients, and mass-energy absorption coefficients are produced by a single computer subroutine. In addition to total interaction cross sections, the cross sections for photoelectric, Rayleigh, Compton, pair, and some triplet interactions are also produced by this single program. The coefficients were compared to the 1970 data of Storm and Israel over the energy interval from 1 to 1000 keV; for elements 10, 20, 30, 40, 50, 60, 70, and 80, the average positive difference between the Storm and Israel coefficients and the coefficients reported here are 1.4%, 2.7%, and 2.6%, for the mass attenuation, mass energy-transfer, and mass-energy absorption coefficients, respectively. The 1969 data compilation of mass attenuation coefficients from McMaster et al. were also compared with the newer LLNL data. Over the energy region from 10 keV to 1000 keV, and from elements Z = 1 to Z = 82 (inclusive), the overall average difference was 1.53% (sigma = 0.85%). While the overall average difference was small, there was larger variation (> 5%) between cross sections for some elements. In addition to coefficient data, other useful data such as the density, atomic weight, K, L1, L2, L3, M, and N edges, and numerous characteristic emission energies are output by the program, depending on a single input variable. The computer source code, written in C, can be accessed and downloaded from the World Wide Web at: http:@www.aip.org/epaps/epaps.html [E-MPHSA-23-1977].
Neutron dosimetric measurements in shuttle and MIR.
Reitz, G
2001-06-01
Detector packages consisting of thermoluminescence detectors (TLD), nuclear emulsions and plastic track detectors were exposed at identical positions inside MIR space station and on shuttle flights inside Spacelab and Spacehab during different phases of the solar cycle. The objectives of the investigations are to provide data on charge and energy spectra of heavy ions, and the contribution of events with low-energy deposit (protons, electrons, gamma, etc.) to the dose, as well as the contribution of secondaries, such as nuclear disintegration stars and neutrons. For neutron dosimetry 6LiF (TLD600) and 7LiF (TLD700) chips were used both of which have almost the same response to gamma rays but different response to neutrons. Neutrons in space are produced mainly in evaporation and knock-on processes with energies mainly of 1-10 MeV and up to several 100 MeV, respectively. The energy spectrum undergoes continuous changes toward greater depth in the attenuating material until an equilibrium is reached. In equilibrium, the spectrum is a wide continuum extending down to thermal energies to which the 6LiF is sensitive. Based on the difference of absorbed doses in the 6LiF and 7LiF chips, thermal neutron fluxes from 1 to 2.3 cm-2 s-1 are calculated using the assumption that the maximum induced dose in TLD600 for 1 neutron cm-2 is 1.6 x 10(-10) Gy (Horowitz and Freeman, Nucl. Instr. and Meth. 157 (1978) 393). It is assumed that the flux of high-energy neutrons is at least of that quantity. Tissue doses were calculated taking as a mean ambient absorbed dose per neutron 6 x10(-12) Gy cm2 (for a10 MeV neutron). The neutron equivalent doses for the above-mentioned fluxes are 52 micro Gy d-1 and 120 micro Gy d-1. In recent experiments, a personal neutron dosimeter was integrated into the dosimeter packages. First results of this dosimeter which is based on nuclear track detectors with converter foils are reported. For future measurements, a scintillator counter with anticoincidence logic is under development. c2001 Elsevier Science Ltd. All rights reserved.
The radiation fields around a proton therapy facility: A comparison of Monte Carlo simulations
NASA Astrophysics Data System (ADS)
Ottaviano, G.; Picardi, L.; Pillon, M.; Ronsivalle, C.; Sandri, S.
2014-02-01
A proton therapy test facility with a beam current lower than 10 nA in average, and an energy up to 150 MeV, is planned to be sited at the Frascati ENEA Research Center, in Italy. The accelerator is composed of a sequence of linear sections. The first one is a commercial 7 MeV proton linac, from which the beam is injected in a SCDTL (Side Coupled Drift Tube Linac) structure reaching the energy of 52 MeV. Then a conventional CCL (coupled Cavity Linac) with side coupling cavities completes the accelerator. The linear structure has the important advantage that the main radiation losses during the acceleration process occur to protons with energy below 20 MeV, with a consequent low production of neutrons and secondary radiation. From the radiation protection point of view the source of radiation for this facility is then almost completely located at the final target. Physical and geometrical models of the device have been developed and implemented into radiation transport computer codes based on the Monte Carlo method. The scope is the assessment of the radiation field around the main source for supporting the safety analysis. For the assessment independent researchers used two different Monte Carlo computer codes named FLUKA (FLUktuierende KAskade) and MCNPX (Monte Carlo N-Particle eXtended) respectively. Both are general purpose tools for calculations of particle transport and interactions with matter, covering an extended range of applications including proton beam analysis. Nevertheless each one utilizes its own nuclear cross section libraries and uses specific physics models for particle types and energies. The models implemented into the codes are described and the results are presented. The differences between the two calculations are reported and discussed pointing out disadvantages and advantages of each code in the specific application.
Molecular characterization of measles viruses that circulated in Cameroon between 2010 and 2011.
Demanou, Maurice; Ratsitoharana, Rajhonson; Yonga, Martial; Dosseh, Annick; Anya, Blanche; Kobela, Marie; Njouom, Richard
2013-03-04
Measles virus (MeV) is monotypic, but genetic variation in the hemagglutinin H and nucleoprotein N genes can be analyzed by molecular epidemiologic techniques and used to study virus transmission patterns. The World Health Organization currently recognizes 8 clades (A-H) within which are 24 genotypes of MeV and one provisional genotype, d11. Genotype B3 is clearly the endemic genotype in most of African continent where it is widely distributed. We provide an update on the molecular characterization of wild-type MeVs that circulated in Cameroon between 2010 and 2011. Viral RNA was extracted directly from samples obtained from clinically diagnosed measles patients using QIAamp viral RNA Mini Kit. Reverse transcription and PCR amplification of 634 nucleotides of the N gene was performed using the SuperScript™ III One-Step. Sequence analysis of 450 of the 634 nucleotides using Clustal X 2.0 program for multiple alignments and Mega version 5 for phylogenic analysis indicated that all the viruses belonged to genotype B3 with two distinct clusters. Twenty three (77%) belonged to subgroup B3.1 and the other 7 (23%) belonged to B3.3 a recently described subtype. Circulation of cluster 3 was detected in the Far-North Region (5/7) particularly along the Chad-Cameroon border in 2010 and later in Yaounde (2/7 in Biyem-assi Health District) the capital city of Cameroon in 2011. This study highlights the endemic circulation in Cameroon of MeV B3 subtype 1, which probably has its source in the neighboring Nigeria, and the presence of the new subtype B3.3, suggesting a possible importation from Northern Africa where it was first described between 2008 and 2009.
An efficient 14-MeV neutron detector for use in mixed 2. 5- and 14-MeV neutron beams
DOE Office of Scientific and Technical Information (OSTI.GOV)
Croft, S.; Bond, D.S.; Hawkes, N.P.
1993-06-01
A neutron detector capable of measuring the time-dependent yield of 14-MeV neutrons from a D--D plasma producing predominantly 2.5-MeV neutrons has been developed. The detector consists of a thick polythene recoil proton radiator backed by a graphite foil attached to a large area totally depleted ion-implanted diode. Protons scattered in the forward direction by 14-MeV neutrons pass through the graphite foil and are registered in the diode. Recoil protons from 2.5-MeV neutrons, however, are prevented from reaching the diode by the foil. When operated with a 1.5-MeV energy bias, the measured neutron detection efficiency for 15-MeV neutrons is 3.2[times]10[sup [minus]3]more » per neutron. The corresponding figure for 3.1-MeV neutrons is a factor of 540 lower. The neutron detector and its laboratory calibration are described, as is its deployment at the Joint European Torus where it serves as a triton burn-up monitor.« less
The stopping power and energy straggling of light ions in graphene oxide foils
NASA Astrophysics Data System (ADS)
Mikšová, R.; Macková, A.; Malinský, P.; Sofer, Z.
2017-09-01
Energy-loss and straggling experiments were performed using 2-4 MeV 1H+ and 7.4-9.0 MeV 4He2+ ions in graphene oxide foils by the transmission technique. The thickness of the graphene oxide foils was determined using a detailed image analysis of a graphene oxide cut, which was used to refine the graphene oxide density. The density was determined by the standard technique of micro-balance weighing. The stoichiometry of the graphene oxide foils before the irradiation was determined by Rutherford backscattering spectrometry (RBS) and elastic recoil detection analysis (ERDA) using 2 and 2.5 MeV 4He+. The measured energy stopping powers for hydrogen and helium ions in graphene oxide were compared with the predictions obtained from the SRIM-2013 code. The energy straggling was compared with that calculated using Bohr's, Bethe-Livingston and Yang predictions. The results show that the stopping power of graphene oxide foils irradiated by both ion species decreases with increasing energies, the differences between the measured and predicted values being below 3.8%. The energy straggling determined in our experiment is higher than Bohr's and Bethe-Livingston predicted values; the predictions by Yang are in better agreement with our experiment.
W Boson Mass Measurement at CDF
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kotwal, Ashutosh V.
2017-03-27
This is the closeout report for the grant for experimental research at the energy frontier in high energy physics. The report describes the precise measurement of the W boson mass at the CDF experiment at Fermilab, with an uncertainty of ≈ 12 MeV, using the full dataset of ≈ 9 fb -1 collected by the experiment up to the shutdown of the Tevatron in 2011. In this analysis, the statistical and most of the experimental systematic uncertainties have been reduced by a factor of two compared to the previous measurement with 2.2 fb -1 of CDF data. This research hasmore » been the culmination of the PI's track record of producing world-leading measurements of the W boson mass from the Tevatron. The PI performed the first and only measurement to date of the W boson mass using high-rapidity leptons using the D0 endcap calorimeters in Run 1. He has led this measurement in Run 2 at CDF, publishing two world-leading measurements in 2007 and 2012 with total uncertainties of 48 MeV and 19 MeV respectively. The analysis of the final dataset is currently under internal review in CDF. Upon approval of the internal review, the result will be available for public release.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
White, R.M.; Browne, J.C.
1982-08-27
The neutron-induced fission cross sections of /sup 242m/Am and /sup 245/Cm have been measured over an energy range of 10/sup -4/ eV to approx. 20 MeV in a series of experiments at three facilities during the past several years. The combined results of these measurements, in which only sub-milligram quantities of enriched isotopes were used, yield cross sections with uncertainties of approximately 5% below 10 MeV relative to the /sup 235/U standard cross section used to normalize the data. We summarize the resonance analysis of the /sup 242m/Am(n,f) cross section in the eV region. Hauser-Feshbach statistical calculations of the detailedmore » fission cross sections of /sup 235/U and /sup 245/Cm have been carried out over the energy region from 0.1 to 5 MeV and these results are compared with our experimental data.« less
Materials for Low-Energy Neutron Radiation Shielding
NASA Technical Reports Server (NTRS)
Singleterry, Robert C., Jr.; Thibeault, Sheila A.
2000-01-01
Various candidate aircraft and spacecraft materials were analyzed and compared in a low-energy neutron environment using the Monte Carlo N-Particle (MCNP) transport code with an energy range up to 20 MeV. Some candidate materials have been tested in particle beams, and others seemed reasonable to analyze in this manner before deciding to test them. The two metal alloys analyzed are actual materials being designed into or used in aircraft and spacecraft today. This analysis shows that hydrogen-bearing materials have the best shielding characteristics over the metal alloys. It also shows that neutrons above 1 MeV are reflected out of the face of the slab better by larger quantities of carbon in the material. If a low-energy absorber is added to the material, fewer neutrons are transmitted through the material. Future analyses should focus on combinations of scatterers and absorbers to optimize these reaction channels and on the higher energy neutron component (above 50 MeV).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Musabaeva, L. I., E-mail: musabaevaLI@oncology.tomsk.ru; Lisin, V. A., E-mail: Lisin@oncology.tomsk.ru; Startseva, Zh. A., E-mail: zhanna.alex@rambler.ru
The analysis of clinical use of neutron therapy with 6 MeV fast neutrons compared to conventional radiation therapy was carried out. The experience of using neutron and mixed neutron and photon therapy in patients with different radio-resistant malignant tumors shows the necessity of further studies and development of the novel approaches to densely-ionizing radiation. The results of dosimetry and radiobiological studies have been the basis for planning clinical programs for neutron therapy. Clinical trials over the past 30 years have shown that neutron therapy successfully destroys radio-resistant cancers, including salivary gland tumors, adenoidcystic carcinoma, inoperable sarcomas, locally advanced head andmore » neck tumors, and locally advanced prostate cancer. Radiation therapy with 6.3 MeV fast neutrons used alone and in combination with photon therapy resulted in improved long-term treatment outcomes in patients with radio-resistant malignant tumors.« less
Detailed characterization of the LLNL imaging proton spectrometer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rasmus, A. M., E-mail: rasmus@lanl.gov, E-mail: arasmus@umich.edu; University of Michigan, Ann Arbor, Michigan 48109; Hazi, A. U.
2016-11-15
Ultra-intense short pulse lasers incident on solid targets (e.g., thin Au foils) produce well collimated, broad-spectrum proton beams. These proton beams can be used to characterize magnetic fields, electric fields, and density gradients in high energy-density systems. The LLNL-Imaging Proton Spectrometer (L-IPS) was designed and built [H. Chen et al., Rev. Sci. Instrum. 81, 10D314 (2010)] for use with such laser produced proton beams. The L-IPS has an energy range of 50 keV-40 MeV with a resolving power (E/dE) of about 275 at 1 MeV and 21 at 20 MeV, as well as a single spatial imaging axis. In ordermore » to better characterize the dispersion and imaging capability of this diagnostic, a 3D finite element analysis solver is used to calculate the magnetic field of the L-IPS. Particle trajectories are then obtained via numerical integration to determine the dispersion relation of the L-IPS in both energy and angular space.« less
A New Approach for Quantitative Evaluation of Ultrasonic Wave Attenuation in Composites
NASA Astrophysics Data System (ADS)
Ni, Qing-Qing; Li, Ran; Xia, Hong
2017-02-01
When ultrasonic waves propagate in composite materials, the propagation behaviors result from the combination effects of various factors, such as material anisotropy and viscoelastic property, internal microstructure and defects, incident wave characteristics and interface condition between composite components. It is essential to make it clear how these factors affect the ultrasonic wave propagation and attenuation characteristics, and how they mutually interact on each other. In the present paper, based on a newly developed time-domain finite element analysis code, PZflex, a unique approach for clarifying the detailed influence mechanism of aforementioned factors is proposed, in which each attenuation component can be extracted from the overall attenuation and analyzed respectively. By taking into consideration the interrelation between each individual attenuation component, the variation behaviors of each component and internal dynamic stress distribution against material anisotropy and matrix viscosity are separately and quantitatively evaluated. From the detailed analysis results of each attenuation component, the energy dissipation at interface is a major component in ultrasonic wave attenuation characteristics, which can provide a maximum contribution rate of 68.2 % to the overall attenuation, and each attenuation component is closely related to the material anisotropy and viscoelasticity. The results clarify the correlation between ultrasonic wave propagation characteristics and material viscoelastic properties, which will be useful in the further development of ultrasonic technology in defect detection.
First measurement of the K-n →Λπ- non-resonant transition amplitude below threshold
NASA Astrophysics Data System (ADS)
Piscicchia, K.; Wycech, S.; Fabbietti, L.; Cargnelli, M.; Curceanu, C.; Del Grande, R.; Marton, J.; Moskal, P.; Scordo, A.; Silarski, M.; Sirghi, D.; Skurzok, M.; Tucakovic, I.; Vázquez Doce, O.; Zmeskal, J.; Branchini, P.; Czerwinski, E.; De Leo, V.; De Lucia, E.; Di Cicco, A.; Fermani, P.; Fiore, S.; Krzemien, W.; Mandaglio, G.; Martini, M.; Perez del Rio, E.; Selce, A.
2018-07-01
We present the analysis of K- absorption processes on 4He leading to Λπ- final states, measured with the KLOE spectrometer at the DAΦNE e+e- collider and extract, for the first time, the modulus of the non-resonant K-n → Λπ- direct production amplitude about 33 MeV below the K ‾N threshold. This analysis also allows to disentangle the K- nuclear absorption at-rest from the in-flight capture, for K- momenta of about 120 MeV. The data are interpreted with the help of a phenomenological model, and the modulus of the non-resonant K-n → Λπ- amplitude for K- absorption at-rest is found to be |A K- n → Λπ- | = (0.334 ± 0.018 stat-0.058+0.034 syst)fm.
Friction wear and auger analysis of iron implanted with 1.5-MeV nitrogen ions
NASA Technical Reports Server (NTRS)
Ferrante, J.; Jones, W. R., Jr.
1982-01-01
The effect of implantation of 1.5-MeV nitrogen ions on the friction and wear characteristics of pure iron sliding against steel was studied in a pin-on disk apparatus. An implantation dose of 5 x 10 to the 17th power ions/sq cm was used. Small reductions in initial and steady-state wear rates were observed for nitrogen-implanted iron riders as compared with unimplanted controls. Auger electron spectroscopy revealed a subsurface Gaussian nitrogen distribution with a maximum concentration of 15 at. % at a depth of 8 x 10 to the -7th m. A similar analysis within the wear scar of an implanted rider after 20 microns of wear yielded only background nitrogen concentration, thus giving no evidence for diffusion of nitrogen beyond the implanted range.
Acquisition and Initial Analysis of H+- and H--Beam Centroid Jitter at LANSCE
NASA Astrophysics Data System (ADS)
Gilpatrick, J. D.; Bitteker, L.; Gulley, M. S.; Kerstiens, D.; Oothoudt, M.; Pillai, C.; Power, J.; Shelley, F.
2006-11-01
During the 2005 Los Alamos Neutron Science Center (LANSCE) beam runs, beam current and centroid-jitter data were observed, acquired, analyzed, and documented for both the LANSCE H+ and H- beams. These data were acquired using three beam position monitors (BPMs) from the 100-MeV Isotope Production Facility (IPF) beam line and three BPMs from the Switchyard transport line at the end of the LANSCE 800-MeV linac. The two types of data acquired, intermacropulse and intramacropulse, were analyzed for statistical and frequency characteristics as well as various other correlations including comparing their phase-space like characteristics in a coordinate system of transverse angle versus transverse position. This paper will briefly describe the measurements required to acquire these data, the initial analysis of these jitter data, and some interesting dilemmas these data presented.
Production of .sup.64 Cu and other radionuclides using a charged-particle accelerator
Welch, Michael J.; McCarthy, Deborah W.; Shefer, Ruth E.; Klinkowstein, Robert E.
2000-01-01
Radionuclides are produced according to the present invention at commercially significant yields and at specific activities which are suitable for use in radiodiagnostic agents such as PET imaging agents and radiotherapeutic agents and/or compositions. In the method and system of the present invention, a solid target having an isotopically enriched target layer electroplated on an inert substrate is positioned in a specially designed target holder and irradiated with a charged-particle beam. The beam is preferably generated using an accelerator such as a biomedical cyclotron at energies ranging from about 5 MeV to about 25 MeV. The target is preferably directly irradiated, without an intervening attenuating foil, and with the charged particle beam impinging an area which substantially matches the target area. The irradiated target is remotely and automatically transferred from the target holder, preferably without transferring any target holder subassemblies, to a conveyance system which is preferably a pneumatic or hydraulic conveyance system, and then further transferred to an automated separation system. The system is effective for processing a single target or a plurality of targets. After separation, the unreacted target material can be recycled for preparation of other targets. In a preferred application of the invention, a biomedical cyclotron has been used to produce over 500 mCi of .sup.64 Cu having a specific activity of over 300 mCi/.mu.g Cu according to the reaction .sup.64 Ni(p,n).sup.64 Cu. These results indicate that accelerator-produced .sup.64 Cu is suitable for radiopharmaceutical diagnostic and therapeutic applications.
Nodal weighting factor method for ex-core fast neutron fluence evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chiang, R. T.
The nodal weighting factor method is developed for evaluating ex-core fast neutron flux in a nuclear reactor by utilizing adjoint neutron flux, a fictitious unit detector cross section for neutron energy above 1 or 0.1 MeV, the unit fission source, and relative assembly nodal powers. The method determines each nodal weighting factor for ex-core neutron fast flux evaluation by solving the steady-state adjoint neutron transport equation with a fictitious unit detector cross section for neutron energy above 1 or 0.1 MeV as the adjoint source, by integrating the unit fission source with a typical fission spectrum to the solved adjointmore » flux over all energies, all angles and given nodal volume, and by dividing it with the sum of all nodal weighting factors, which is a normalization factor. Then, the fast neutron flux can be obtained by summing the various relative nodal powers times the corresponding nodal weighting factors of the adjacent significantly contributed peripheral assembly nodes and times a proper fast neutron attenuation coefficient over an operating period. A generic set of nodal weighting factors can be used to evaluate neutron fluence at the same location for similar core design and fuel cycles, but the set of nodal weighting factors needs to be re-calibrated for a transition-fuel-cycle. This newly developed nodal weighting factor method should be a useful and simplified tool for evaluating fast neutron fluence at selected locations of interest in ex-core components of contemporary nuclear power reactors. (authors)« less
Gridelli, C; Perrone, F; Palmeri, S; D'Aprile, M; Cognetti, F; Rossi, A; Gebbia, V; Pepe, R; Veltri, E; Airoma, G; Russo, A; Incoronato, P; Scinto, A F; Palazzolo, G; Natali, M; Leonardi, V; Gallo, C; De Placido, S; Bianco, A R
1996-10-01
To compare mitomycin C plus vindesine plus etoposide (MEV) vs. mitomycin C plus vindesine plus cisplatin (MVP) in the treatment of stage IV non-small-cell lung cancer. 204 patients were entered in a phase III multicentre randomised trial from June 1990 to December 1994 and stratified according to the ECOG performance status (0-1 vs. 2). MVP was given in the following dosages: mitomycin C 8 mg/m2+vindesine 3 mg/m2+cisplatin 100 mg/m2 i.v. day 1 and vindesine 3 mg/m2 i.v. day 8 with cycles repeated every 4 weeks. MEV was given in the following dosages: mitomycin C 8 mg/m2+vindesine 3 mg/ m2 i.v. day 1 and etoposide 100 mg/m2 i.v. days 1 to 3 with cycles repeated every 3 weeks. For both treatments a maximum of 6 cycles was planned. Response and toxicity were evaluated according to WHO. Subjective responses were assessed by numerical scales. Analyses were made on the basis of intent to treat. The objective response rate was 21.4% (1 CR + 21 PR among 103 patients) in the MEV and 28.7% (1 CR + 28 PR among 101 patients) in the MVP arm (P = 0.48). Symptoms were similar in the two arms. 196 patients progressed and 182 died. The median times to progression were 10 weeks (95% CI 9-12) and 12 weeks (95% CI 10-15) and median survivals were 29 weeks (95% CI 25-36) and 28 weeks (95% CI 25-35) in the MEV and MVP arms, respectively. The relative risks of progressing and of dying were 0.89 (95% CL 0.66-1.20) and 0.96 (95% CL 0.71-1.30), respectively, for patients receiving MVP as compared with those receiving MEV at multivariate analysis adjusted by sex, age, histologic type, number of metastatic sites, performance status at entry, and centre. In the present study, no significant differences were observed in response rate, survival or palliation of symptoms between the MEV and MVP regimens, while toxicity was significantly more frequent and severe with MVP. Thus, MEV should be considered a reasonable alternative to the MVP regimen in the treatment of stage IV NSCLC.
The Physics Analysis of a Gas Attenuator with Argon as a Working Gas
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ryutov,, D.D.
2010-12-07
A gas attenuator is an important element of the LCLS facility. The attenuator must operate in a broad range of x-ray energies, provide attenuation coefficient between 1 and 10{sup 4} with the accuracy of 1% and, at the same time, be reliable and allow for many months of un-interrupted operation. S. Shen has recently carried out a detailed design study of the attenuator based on the use of nitrogen as a working gas. In this note we assess the features of the attenuator based on the use of argon. We concentrate on the physics issues, not the design features.
QPM Analysis of 205Tl Nuclear Excitations below the Giant Dipole Resonance
NASA Astrophysics Data System (ADS)
Benouaret, N.; Beller, J.; Isaak, J.; Kelley, J. H.; Pai, H.; Pietralla, N.; Ponomarev, V. Yu.; Raut, R.; Romig, C.; Rusev, G.; Savran, D.; Scheck, M.; Schnorrenberger, L.; Sonnabend, K.; Tonchev, A. P.; Tornow, W.; Weller, H. R.; Zweidinger, M.
2015-05-01
We analysed our experimental recent findings of the dipole response of the odd-mass stable nucleus 205Tl within the quasi-particle phonon model. Using the phonon basis constructed for the neighbouring 204Hg and wave function configurations for 205Tl consisting of a mixture of quasiparticle ⊗ N-phonon configurations (N=0,1,2), only one group of fragmented dipole excited states has been reproduced at 5.5 MeV in comparison to the experimental distribution which shows a second group at about 5 MeV. The computed dipole transition strengths are mainly of E1 character which could be associated to the pygmy dipole resonance.
VizieR Online Data Catalog: Fermi-LAT flaring gamma-ray sources from FAVA (Ackermann+, 2013)
NASA Astrophysics Data System (ADS)
Ackermann, M.; Ajello, M.; Albert, A.; Allafort, A.; Antolini, E.; Baldini, L.; Ballet, J.; Barbiellini, G.; Bastieri, D.; Bechtol, K.; Bellazzini, R.; Blandford, R. D.; Bloom, E. D.; Bonamente, E.; Bottacini, E.; Bouvier, A.; Brandt, T. J.; Bregeon, J.; Brigida, M.; Bruel, P.; Buehler, R.; Buson, S.; Caliandro, G. A.; Cameron, R. A.; Caraveo, P. A.; Cavazzuti, E.; Cecchi, C.; Charles, E.; Chekhtman, A.; Cheung, C. C.; Chiang, J.; Chiaro, G.; Ciprini, S.; Claus, R.; Cohen-Tanugi, J.; Conrad, J.; Cutini, S.; Dalton, M.; D'Ammando, F.; de Angelis, A.; de Palma, F.; Dermer, C. D.; di Venere, L.; Drell, P. S.; Drlica-Wagner, A.; Favuzzi, C.; Fegan, S. J.; Ferrara, E. C.; Focke, W. B.; Franckowiak, A.; Fukazawa, Y.; Funk, S.; Fusco, P.; Gargano, F.; Gasparrini, D.; Germani, S.; Giglietto, N.; Giordano, F.; Giroletti, M.; Glanzman, T.; Godfrey, G.; Grenier, I. A.; Grondin, M.-H.; Grove, J. E.; Guiriec, S.; Hadasch, D.; Hanabata, Y.; Harding, A. K.; Hayashida, M.; Hays, E.; Hewitt, J.; Hill, A. B.; Horan, D.; Hou, X.; Hughes, R. E.; Inoue, Y.; Jackson, M. S.; Jogler, T.; Johannesson, G.; Johnson, W. N.; Kamae, T.; Kataoka, J.; Kawano, T.; Knodlseder, J.; Kuss, M.; Lande, J.; Larsson, S.; Latronico, L.; Lemoine-Goumard, M.; Longo, F.; Loparco, F.; Lott, B.; Lovellette, M. N.; Lubrano, P.; Mayer, M.; Mazziotta, M. N.; McEnery, J. E.; Michelson, P. F.; Mitthumsiri, W.; Mizuno, T.; Monte, C.; Monzani, M. E.; Morselli, A.; Moskalenko, I. V.; Murgia, S.; Nemmen, R.; Nuss, E.; Ohsugi, T.; Okumura, A.; Omodei, N.; Orienti, M.; Orlando, E.; Ormes, J. F.; Paneque, D.; Panetta, J. H.; Perkins, J. S.; Pesce-Rollins, M.; Piron, F.; Pivato, G.; Porter, T. A.; Raino, S.; Rando, R.; Razzano, M.; Reimer, A.; Reimer, O.; Romoli, C.; Roth, M.; Sanchez-Conde, M.; Scargle, J. D.; Schulz, A.; Sgro, C.; Siskind, E. J.; Spandre, G.; Spinelli, P.; Suson, D. J.; Takahashi, H.; Takeuchi, Y.; Thayer, J. G.; Thayer, J. B.; Thompson, D. J.; Tibaldo, L.; Tinivella, M.; Torres, D. F.; Tosti, G.; Troja, E.; Tronconi, V.; Usher, T. L.; Vandenbroucke, J.; Vasileiou, V.; Vianello, G.; Vitale, V.; Winer, B. L.; Wood, K. S.; Wood, M.; Yang, Z.
2015-01-01
We applied FAVA (Fermi All-sky Variability Analysis) to the first 47 months of Fermi/LAT observations (2008 August 4 to 2012 July 16 UTC), in weekly time intervals. The total number of weeks is 206. We considered two ranges of gamma-ray energy, E>100MeV and E>800MeV, to increase the sensitivity for spectrally soft and hard flares, respectively. We generate measured and expected count maps with a resolution of 0.25deg2 per pixel. We found LAT counterparts for 192 of the 215 FAVA sources. Most of the associated sources, 177, are AGNs. (2 data files).
Constraints from primordial nucleosynthesis on the mass of the tau neutrino
NASA Technical Reports Server (NTRS)
Kolb, Edward W.; Turner, Michael S.; Chakravorty, A.; Schramm, David N.
1991-01-01
It is shown that primordial nucleosynthesis excludes a tau-neutrino mass from 0.3 to 25 MeV (Dirac) and 0.5 to 25 MeV (Majorana) provided that its lifetime is not less than about 1 sec, and from 0.3 to 30 MeV (Dirac) and 0.5 to 32 MeV (Majorana) for a lifetime of not less than about 1000 sec. A modest improvement in the laboratory mass limit - from 35 to 25 MeV - would imply that the tau-neutrino mass must be less than 0.5 MeV (provided the lifetime is not less than about 1 sec).
Moisture effect in prompt gamma measurements from soil samples.
Naqvi, A A; Khiari, F Z; Liadi, F A; Khateeb-Ur-Rehman; Raashid, M A; Isab, A H
2016-09-01
The variation in intensity of 1.78MeV silicon, 6.13MeV oxygen, and 2.22MeV hydrogen prompt gamma rays from soil samples due to the addition of 5.1, 7.4, 9.7, 11.9 and 14.0wt% water was studied for 14MeV incident neutron beams utilizing a LaBr3:Ce gamma ray detector. The intensities of 1.78MeV and 6.13MeV gamma rays from silicon and oxygen, respectively, decreased with increasing sample moisture. The intensity of 2.22MeV hydrogen gamma rays increases with moisture. The decrease in intensity of silicon and oxygen gamma rays with moisture concentration indicates a loss of 14MeV neutron flux, while the increase in intensity of 2.22MeV gamma rays with moisture indicates an increase in thermal neutron flux due to increasing concentration of moisture. The experimental intensities of silicon, oxygen and hydrogen prompt gamma rays, measured as a function of moisture concentration in the soil samples, are in good agreement with the theoretical results obtained through Monte Carlo calculations. Copyright © 2016 Elsevier Ltd. All rights reserved.
Comparative proteomic analysis of virulent and rifampicin attenuated Flavobacterium psychrophilum
USDA-ARS?s Scientific Manuscript database
Flavobacterium psychrophilum is the etiologic agent of bacterial coldwater disease and rainbow trout fry syndrome. In this study we compared a wild-type strain (CSF 259.93) with a rifampicin resistant and virulence attenuated strain of F. psychrophilum (CSF 259.93B.17). The attenuated strain harbour...
Lascola, Kara M; O'Brien, Robert T; Wilkins, Pamela A; Clark-Price, Stuart C; Hartman, Susan K; Mitchell, Mark A
2013-09-01
To qualitatively describe lung CT images obtained from sedated healthy equine neonates (≤ 14 days of age), use quantitative analysis of CT images to characterize attenuation and distribution of gas and tissue volumes within the lungs, and identify differences between lung characteristics of foals ≤ 7 days of age and foals > 7 days of age. 10 Standardbred foals between 2.5 and 13 days of age. Foals were sedated with butorphanol, midazolam, and propofol and positioned in sternal recumbency for thoracic CT. Image analysis software was used to exclude lung from nonlung structures. Lung attenuation was measured in Hounsfield units (HU) for analysis of whole lung and regional changes in attenuation and lung gas and tissue components. Degree of lung attenuation was classified as follows: hyperinflated or emphysema, -1,000 to -901 HU; well aerated, -900 to -501 HU; poorly aerated, -500 to -101 HU; and nonaerated, > -100 HU. Qualitative evidence of an increase in lung attenuation and patchy alveolar patterns in the ventral lung region were more pronounced in foals ≤ 7 days of age than in older foals. Quantitative analysis revealed that mean ± SD lung attenuation was greater in foals ≤ 7 days of age (-442 ± 28 HU) than in foals > 7 days of age (-521 ± 24 HU). Lung aeration and gas volumes were lower than in other regions ventrally and in the mid lung region caudal to the heart. CONCLUSIONS AND CLINICAL RELEVANCE-Identified radiographic patterns and changes in attenuation were most consistent with atelectasis and appeared more severe in foals ≤ 7 days of age than in older neonatal foals. Recognition of these changes may have implications for accurate CT interpretation in sedated neonatal foals with pulmonary disease.
Refractive effects and Airy structure in inelastic 16O+12C rainbow scattering
NASA Astrophysics Data System (ADS)
Ohkubo, S.; Hirabayashi, Y.; Ogloblin, A. A.; Gloukhov, Yu. A.; Dem'yanova, A. S.; Trzaska, W. H.
2014-12-01
Inelastic 16O+12C rainbow scattering to the 2+ (4.44 MeV) state of 12C was measured at the incident energies, EL = 170, 181, 200, 260, and 281 MeV. A systematic analysis of the experimental angular distributions was performed using the coupled-channels method with an extended double folding potential derived from realistic wave functions for 12C and 16O calculated with a microscopic α cluster model and a finite-range density-dependent nucleon-nucleon force. The coupled-channels analysis of the measured inelastic-scattering data shows consistently some Airy-like structure in the inelastic-scattering cross sections for the first 2+ state of 12C, which is somewhat obscured and still not clearly visible in the measured data. The Airy minimum was identified from the analysis and the systematic energy evolution of the Airy structure was studied. The Airy minimum in inelastic scattering is found to be shifted backward compared with that in elastic scattering.
NASA Astrophysics Data System (ADS)
Patel, Gnansagar B.; Bhavsar, Shilpa; Singh, N. L.; Singh, F.; Kulriya, P. K.
2016-07-01
Poly ethylene oxide (PEO) films were synthesized by solution cast method. These self-standing films were exposed with 60 MeV C+5 ion and 100 MeV Ni+7 ion at different fluences. SHI induced effect was investigated by employing various techniques. The crystalline size decreased upon irradiation as observed from XRD analysis. FTIR analysis reveals the decrement in the peak intensity upon irradiation. Tauc's method was used to determine the optical band gap (Eg), which shows decreasing trends with increase of fluence. The dielectric properties were investigated in the frequency range 10 Hz to 10 MHz for unirradiated and irradiated films. The dielectric constant remains same for the broad-spectrum of frequency and increases at lower frequency. The dielectric loss also moderately influence as a function of frequency due to irradiation. DSC analysis validated the results of XRD. Scanning electron microscopy (SEM) reveals that there is significant change in the surface morphology due to irradiation.
Seismic Attenuation, Event Discrimination, Magnitude and Yield Estimation, and Capability Analysis
2011-09-01
waves are subject to path-dependent variations in amplitudes. We see geographic similarities between the crustal shear-wave attenuation and the...either Sn or Lg depending on tectonic region, distance, and frequency. Over the past year, we have made great progress on the calibration of surface...between the crustal shear-wave attenuation and the results from the coda attenuation. Calibration of coda in the Middle East and other areas is
Markerless attenuation correction for carotid MRI surface receiver coils in combined PET/MR imaging
NASA Astrophysics Data System (ADS)
Eldib, Mootaz; Bini, Jason; Robson, Philip M.; Calcagno, Claudia; Faul, David D.; Tsoumpas, Charalampos; Fayad, Zahi A.
2015-06-01
The purpose of the study was to evaluate the effect of attenuation of MR coils on quantitative carotid PET/MR exams. Additionally, an automated attenuation correction method for flexible carotid MR coils was developed and evaluated. The attenuation of the carotid coil was measured by imaging a uniform water phantom injected with 37 MBq of 18F-FDG in a combined PET/MR scanner for 24 min with and without the coil. In the same session, an ultra-short echo time (UTE) image of the coil on top of the phantom was acquired. Using a combination of rigid and non-rigid registration, a CT-based attenuation map was registered to the UTE image of the coil for attenuation and scatter correction. After phantom validation, the effect of the carotid coil attenuation and the attenuation correction method were evaluated in five subjects. Phantom studies indicated that the overall loss of PET counts due to the coil was 6.3% with local region-of-interest (ROI) errors reaching up to 18.8%. Our registration method to correct for attenuation from the coil decreased the global error and local error (ROI) to 0.8% and 3.8%, respectively. The proposed registration method accurately captured the location and shape of the coil with a maximum spatial error of 2.6 mm. Quantitative analysis in human studies correlated with the phantom findings, but was dependent on the size of the ROI used in the analysis. MR coils result in significant error in PET quantification and thus attenuation correction is needed. The proposed strategy provides an operator-free method for attenuation and scatter correction for a flexible MRI carotid surface coil for routine clinical use.
NASA Astrophysics Data System (ADS)
Lucente, F. P.; Piccinini, D.; Dibona, M.; Levin, V.; Park, J.
2007-12-01
We present preliminary results for seismic attenuation in the mantle beneath the Italian region. We estimate P- and S-wave spectral ratios from teleseisms recorded at the temporary broadband seismic network deployed during the RETREAT (Retreating-TRrench, Extension, and Accretion Tectonics) project. We examine body-wave attenuation variation across the northern part of the Apennines mountain belt, which represents the accretionary wedge exposed during recent episodes of the subduction process in Italy. The data recorded during the three-year seismic campaign were analyzed using an ad hoc semi-automated procedure based on the cross-correlation analysis of a single phase across all the stations for each event. The seismic phases analyzed (P, S, SKS) display different patterns of seismic attenuation. Furthermore, we observe systematic variations in the distribution of the attenuation values as function of both the azimuth and the incidence angle of the seismic rays. Relatively high attenuation values are found on the Tyrrhenian side by seismic rays coming from the SW for both P- and S-phases. For NE-approaching rays the pattern of high attenuation values varies considerably, depending on the seismic phases: for P-waves it grossly corresponds to the mountain belt, while for S-waves it extends over almost the whole study area. By correlating attenuation estimates and the velocity structure from the existing tomographic models, we can make some inferences on the thermal state of the sublithospheric mantle, and on the physical properties of the tectonic elements which constitute the subduction system in the region. From the analysis of the P-phases we can clearly distinguish three main areas with different attenuation values, corresponding to the back-arc mantle (high attenuation), to the slab (low attenuation) and to the retro-slab mantle (high attenuation). The correspondence between the identified elements of the subduction system and the S- waves attenuation is not straightforward, and need to be further investigated.
Exploration of nucleoprotein α-MoRE and XD interactions of Nipah and Hendra viruses.
Shang, Xu; Chu, Wenting; Chu, Xiakun; Xu, Liufang; Longhi, Sonia; Wang, Jin
2018-04-24
Henipavirus, including Hendra virus (HeV) and Nipah virus (NiV), is a newly discovered human pathogen genus. The nucleoprotein of Henipavirus contains an α-helical molecular recognition element (α-MoRE) that folds upon binding to the X domain (XD) of the phosphoprotein (P). In order to explore the conformational dynamics of free α-MoREs and the underlying binding-folding mechanism with XD, atomic force field-based and hybrid structure-based MD simulations were carried out. In our empirical force field-based simulations, characteristic structures and helicities of α-MoREs reveal the co-existence of partially structured and disordered conformations, as in the case of the well characterized cognate measles virus (MeV) α-MoRE. In spite of their overall similarity, the two α-MoREs display subtle helicity differences in their C-terminal region, but much different from that of MeV. For the α-MoRE/XD complexes, the results of our hybrid structure-based simulations provide the coupled binding-folding landscapes, and unveil a wide conformational selection mechanism at early binding stages, followed by a final induce-fit mechanism selection process. However, the HeV and NiV complexes have a lower binding barrier compared to that of MeV. Moreover, the HeV α-MoRE/XD complex shows much less coupling effects between binding and folding compared to that from both NiV and MeV. Our analysis revealed that contrary to NiV and MeV, the N- and C-terminal regions of the HeV α-MoRE maintains a low helicity also in the bound form.
Independent Structural Domains in Paramyxovirus Polymerase Protein*
Dochow, Melanie; Krumm, Stefanie A.; Crowe, James E.; Moore, Martin L.; Plemper, Richard K.
2012-01-01
All enzymatic activities required for genomic replication and transcription of nonsegmented negative strand RNA viruses (or Mononegavirales) are believed to be concentrated in the viral polymerase (L) protein. However, our insight into the organization of these different enzymatic activities into a bioactive tertiary structure remains rudimentary. Fragments of Mononegavirales polymerases analyzed to date cannot restore bioactivity through trans-complementation, unlike the related L proteins of segmented NSVs. We investigated the domain organization of phylogenetically diverse Paramyxovirus L proteins derived from measles virus (MeV), Nipah virus (NiV), and respiratory syncytial virus (RSV). Through a comprehensive in silico and experimental analysis of domain intersections, we defined MeV L position 615 as an interdomain candidate in addition to the previously reported residue 1708. Only position 1708 of MeV and the homologous positions in NiV and RSV L also tolerated the insertion of epitope tags. Splitting of MeV L at residue 1708 created fragments that were unable to physically interact and trans-complement, but strikingly, these activities were reconstituted by the addition of dimerization tags to the fragments. Equivalently split fragments of NiV, RSV, and MeV L oligomerized with comparable efficiency in all homo- and heterotypic combinations, but only the homotypic pairs were able to trans-complement. These results demonstrate that synthesis as a single polypeptide is not required for the Mononegavirales polymerases to adopt a proper tertiary conformation. Paramyxovirus polymerases are composed of at least two truly independent folding domains that lack a traditional interface but require molecular compatibility for bioactivity. The functional probing of the L domain architecture through trans-complementation is anticipated to be applicable to all Mononegavirales polymerases. PMID:22215662
Study of the Most Harmful Solar Energetic Particle for Shielding next Human Space Flights
NASA Astrophysics Data System (ADS)
Komei Yamashiro, Bryan
2015-04-01
Solar energetic particles (SEPs) accelerated by solar events such as flares and coronal mass ejections are radiation risks for humans in space on board the International Space Station (ISS), and will be significant obstacles for future long-duration manned space flight missions. This research supported efforts to improve predictions of large solar storms and aimed for a better understanding of Heliophysics. The main objective was to generate a dated catalog of the highest energy range SEPs measured by the Alpha Magnetic Spectrometer (AMS-02). Using online graphical user interfaces from the satellites, Solar and Heliospeheric Observatory (SOHO) and Geostationary Operational Environmental Satellite (GOES-13, 15), the generated data files from the mounted particle detectors were plotted along a specified energy range. The resulting histograms illustrated the low energy range data from SOHO (4 MeV to 53 MeV) and the low-mid energy range from GOES (0.8 MeV to 500 MeV), which collectively provided a low- to mid-energy range spectrum of the specific event energy ranges versus the SEP proton flux. The high energy range results of the AMS-02 (125 MeV to a few TeV) will eventually be incorporated with the two alternative space satellites of lower energy ranges for a complete analysis across a full SEP energy range. X-ray flux from GOES-15 were then obtained and plotted with the corresponding time to portray initial phenomena of the solar events. This procedure was reproduced for 5 different events determined energetic enough to be measured by AMS-02. The generated plots showed correlation between the different satellite detectors.
High-energy photon interrogation for nonproliferation applications
NASA Astrophysics Data System (ADS)
Jones, J. L.; Blackburn, B. W.; Watson, S. M.; Norman, D. R.; Hunt, A. W.
2007-08-01
There is an immediate need for technologies that can successfully address homeland security challenges related to the inspection of commercial rail, air and maritime-cargo container inspections for nuclear and radiological devices. The pulsed photonuclear assessment (PPA) technology, developed through collaboration between Idaho National Laboratory (INL), Los Alamos National Laboratory (LANL) and the Idaho Accelerator Center (IAC) has demonstrated the ability to detect shielded/unshielded nuclear material primarily through the analysis of delayed neutrons and gamma-rays produced via photonuclear reactions. Because of current food irradiation limitations, however, most active photon (i.e. bremsstrahlung) interrogation studies have been performed with electron beam energies at or below 10 MeV. While this energy limit currently applies to cargo inspections, the World Health Organization has indicated that higher energy electron beam operations could be considered for future operations. Clinical applications using photon energies well in excess of 10 MeV are already well established. Notwithstanding the current limitation of 10 MeV, there is a definite advantage in using higher photon energies for cargo inspections. At higher energies, several phenomena contribute to increased sensitivity in regards to detecting shielded nuclear material. Two of the most important are: (1) increased ability for source photons to penetrate shielding; and (2) enhanced signature production via increased (γ,n) and (γ,f) cross-sections in materials such as 235U and 239Pu directly leading to faster inspection throughput. Experimental assessments have been conducted for various electron beam energies from 8 to 25 MeV. Increases of up to three orders of magnitude in delayed signatures have been measured over these energy ranges. Through the continued investigation into PPA-based inspection applications using photon energies greater than 10 MeV, higher detection sensitivities with potentially lower delivered dose to cargo and increased throughput may be realized.
2015-09-01
used to simulate 50- 150MeV VHEE beam dose deposition and its effects on steel and titanium (Ti) heterogeneities in a water phantom. Heterogeneities of...and water with segmented prostheses ( steel and Ti) geometries with 100MeV and 150MeV beams. Results: 100MeV PDD 5cm behind steel /Ti heterogeneity...in steel and 18% in Ti heterogeneities. The dose immediately behind steel heterogeneity decreased by an average of 6%, although for 150MeV, the
Phase Aberration and Attenuation Effects on Acoustic Radiation Force-Based Shear Wave Generation.
Carrascal, Carolina Amador; Aristizabal, Sara; Greenleaf, James F; Urban, Matthew W
2016-02-01
Elasticity is measured by shear wave elasticity imaging (SWEI) methods using acoustic radiation force to create the shear waves. Phase aberration and tissue attenuation can hamper the generation of shear waves for in vivo applications. In this study, the effects of phase aberration and attenuation in ultrasound focusing for creating shear waves were explored. This includes the effects of phase shifts and amplitude attenuation on shear wave characteristics such as shear wave amplitude, shear wave speed, shear wave center frequency, and bandwidth. Two samples of swine belly tissue were used to create phase aberration and attenuation experimentally. To explore the phase aberration and attenuation effects individually, tissue experiments were complemented with ultrasound beam simulations using fast object-oriented C++ ultrasound simulator (FOCUS) and shear wave simulations using finite-element-model (FEM) analysis. The ultrasound frequency used to generate shear waves was varied from 3.0 to 4.5 MHz. Results: The measured acoustic pressure and resulting shear wave amplitude decreased approximately 40%-90% with the introduction of the tissue samples. Acoustic intensity and shear wave displacement were correlated for both tissue samples, and the resulting Pearson's correlation coefficients were 0.99 and 0.97. Analysis of shear wave generation with tissue samples (phase aberration and attenuation case), measured phase screen, (only phase aberration case), and FOCUS/FEM model (only attenuation case) showed that tissue attenuation affected the shear wave generation more than tissue aberration. Decreasing the ultrasound frequency helped maintain a focused beam for creation of shear waves in the presence of both phase aberration and attenuation.
NASA Astrophysics Data System (ADS)
Zhu, Tieyuan; Ajo-Franklin, Jonathan B.; Daley, Thomas M.
2017-09-01
A continuous active source seismic monitoring data set was collected with crosswell geometry during CO2 injection at the Frio-II brine pilot, near Liberty, TX. Previous studies have shown that spatiotemporal changes in the P wave first arrival time reveal the movement of the injected CO2 plume in the storage zone. To further constrain the CO2 saturation, particularly at higher saturation levels, we investigate spatial-temporal changes in the seismic attenuation of the first arrivals. The attenuation changes over the injection period are estimated by the amount of the centroid frequency shift computed by local time-frequency analysis. We observe that (1) at receivers above the injection zone seismic attenuation does not change in a physical trend; (2) at receivers in the injection zone attenuation sharply increases following injection and peaks at specific points varying with distributed receivers, which is consistent with observations from time delays of first arrivals; then, (3) attenuation decreases over the injection time. The attenuation change exhibits a bell-shaped pattern during CO2 injection. Under Frio-II field reservoir conditions, White's patchy saturation model can quantitatively explain both the P wave velocity and attenuation response observed. We have combined the velocity and attenuation change data in a crossplot format that is useful for model-data comparison and determining patch size. Our analysis suggests that spatial-temporal attenuation change is not only an indicator of the movement and saturation of CO2 plumes, even at large saturations, but also can quantitatively constrain CO2 plume saturation when used jointly with seismic velocity.
In-situ soil carbon analysis using inelastic neutron scattering
USDA-ARS?s Scientific Manuscript database
In situ soil carbon analysis using inelastic neutron scattering (INS) is based on the emission of 4.43 MeV gamma rays from carbon nuclei excited by fast neutrons. This in-situ method has excellent potential for easily measuring soil carbon since it does not require soil core sampling and processing ...
Continuous versus pulse neutron induced gamma spectroscopy for soil carbon analysis
USDA-ARS?s Scientific Manuscript database
Neutron induced gamma spectra analysis (NGA) provides a means of measuring carbon in large soil volumes without destructive sampling. Calibration of the NGA system must account for system background and the interference of other nuclei on the carbon peak at 4.43 MeV. Accounting for these factors pro...
NASA Astrophysics Data System (ADS)
Ghias, Asghar
1999-11-01
Neutron activation methods and bore-hole gamma-ray spectrometry have been versatile techniques for real time field evaluation in mineral exploration. The most common neutron generators producing 14 MeV and 2.5 MeV neutrons accelerate deuterium ions into a tritium or deuterium target via the 3H( 2H,n)4He or the 2H(2H,n) 3H reactions. The development and design of bore-hole 2.5 MeV high flux neutron generator coupled with an efficient gamma-ray detector is the primary focus of this work, which is needed by the coal and petroleum industries. A 2.5 MeV neutron generator, which used the D(D,n)T reaction, was constructed similar to a conventional Zetatron 14 MeV generator. The performance of the low energy neutron generator was studied under various operating conditions. In order to enhance the neutron flux of the generator, an r.f. field was applied to the ion source which increased the neutron yield per pulse by about thirty percent. A theoretical study of the r.f enhancement has been made to explain the operation of the r.f. added Zetatron tube. An alternative, method of neutron flux enhancement by use of laser-excitation is discussed and explained theoretically. The laser technique although not experimentally verified, is based on the recent development of vibronic lasers, the neutron flux can be enhanced several orders of magnitude by precise tuning of the wavelength within vibronic band. Activation experiments using a large coal sample (about I ton) were conducted, and studies were made on inter and intrapulse counting, detector gated spectra, and comparison of the spectra using different neutron sources. Preliminary results on coal analysis reveal that lower energy (2.5 MeV) is superior to high energy (14 MeV) neutrons. During the course of this work it became necessary to measure fast neutrons, efficiently and in real time. A new type of detector was consequently developed using SnO2 as sheath material around a BGO detector to measure the capture gamma-rays of oxygen. Using neutron activation studies of coal, the feasibility of applying the technique to aid medical diagnostics is also discussed in this dissertation.
COMPTEL solar flare observations
NASA Technical Reports Server (NTRS)
Ryan, J. M.; Aarts, H.; Bennett, K.; Debrunner, H.; Devries, C.; Denherder, J. W.; Eymann, G.; Forrest, D. J.; Diehl, R.; Hermsen, W.
1992-01-01
COMPTEL as part of a solar target of opportunity campaign observed the sun during the period of high solar activity from 7-15 Jun. 1991. Major flares were observed on 9 and 11 Jun. Although both flares were large GOES events (greater than or = X10), they were not extraordinary in terms of gamma-ray emission. Only the decay phase of the 15 Jun. flare was observed by COMPTEL. We report the preliminary analysis of data from these flares, including the first spectroscopic measurement of solar flare neutrons. The deuterium formation line at 2.223 MeV was present in both events and for at least the 9 Jun. event, was comparable to the flux in the nuclear line region of 4-8 MeV, consistent with Solar-Maximum Mission (SSM) Observations. A clear neutron signal was present in the flare of 9 Jun. with the spectrum extending up to 80 MeV and consistent in time with the emission of gamma-rays, confirming the utility of COMPTEL in measuring the solar neutron flux at low energies. The neutron flux below 100 MeV appears to be lower than that of the 3 Jun. 1982 flare by more than an order of magnitude. The neutron signal of the 11 Jun. event is under study. Severe dead time effects resulting from the intense thermal x-rays require significant corrections to the measured flux which increase the magnitude of the associated systematic uncertainties.
Detection of fissionable materials in cargoes using monochromatic photon radiography
NASA Astrophysics Data System (ADS)
Danagoulian, Areg; Lanza, Richard; O'Day, Buckley; LNSP Team
2015-04-01
The detection of Special Nuclear Materials (e.g. Pu and U) and nuclear devices in the commercial cargo traffic is one of the challenges posed by the threat of nuclear terrorism. Radiography and active interrogation of heavily loaded cargoes require ~ 1 - 10MeV photons for penetration. In a proof-of-concept system under development at MIT, the interrogating monochromatic photon beam is produced via a 11B(d , nγ) 12C reaction. To achieve this, a boron target is used along with the 3 MeV d+ RFQ accelerator at MIT-Bates. The reactions results in the emission of very narrow 4.4 MeV and 15.1 MeV gammas lines. The photons, after traversing the cargo, are detected by an array of NaI(Tl) detectors. A spectral analysis of the transmitted gammas allows to independently determine the areal density and the atomic number (Z) of the cargo. The proposed approach could revolutionize cargo inspection, which, in its current fielded form has to rely on simple but high dose bremsstrahlung sources. Use of monochromatic sources would significantly reduce the necessary dose and allow for better determination of the cargo's atomic number. The general methodology will be described and the preliminary results from the proof-of-concept system will be presented and discussed. Supported by NSF/DNDO Collaborative Research ARI-LA Award ECCS-1348328.
Jeong, Tae Won; Singh, P K; Scullion, C; Ahmed, H; Kakolee, K F; Hadjisolomou, P; Alejo, A; Kar, S; Borghesi, M; Ter-Avetisyan, S
2016-08-01
The absolute calibration of a microchannel plate (MCP) assembly using a Thomson spectrometer for laser-driven ion beams is described. In order to obtain the response of the whole detection system to the particles' impact, a slotted solid state nuclear track detector (CR-39) was installed in front of the MCP to record the ions simultaneously on both detectors. The response of the MCP (counts/particles) was measured for 5-58 MeV carbon ions and for protons in the energy range 2-17.3 MeV. The response of the MCP detector is non-trivial when the stopping range of particles becomes larger than the thickness of the detector. Protons with energies E ≳ 10 MeV are energetic enough that they can pass through the MCP detector. Quantitative analysis of the pits formed in CR-39 and the signal generated in the MCP allowed to determine the MCP response to particles in this energy range. Moreover, a theoretical model allows to predict the response of MCP at even higher proton energies. This suggests that in this regime the MCP response is a slowly decreasing function of energy, consistently with the decrease of the deposited energy. These calibration data will enable particle spectra to be obtained in absolute terms over a broad energy range.
NASA Astrophysics Data System (ADS)
Jeong, Tae Won; Singh, P. K.; Scullion, C.; Ahmed, H.; Kakolee, K. F.; Hadjisolomou, P.; Alejo, A.; Kar, S.; Borghesi, M.; Ter-Avetisyan, S.
2016-08-01
The absolute calibration of a microchannel plate (MCP) assembly using a Thomson spectrometer for laser-driven ion beams is described. In order to obtain the response of the whole detection system to the particles' impact, a slotted solid state nuclear track detector (CR-39) was installed in front of the MCP to record the ions simultaneously on both detectors. The response of the MCP (counts/particles) was measured for 5-58 MeV carbon ions and for protons in the energy range 2-17.3 MeV. The response of the MCP detector is non-trivial when the stopping range of particles becomes larger than the thickness of the detector. Protons with energies E ≳ 10 MeV are energetic enough that they can pass through the MCP detector. Quantitative analysis of the pits formed in CR-39 and the signal generated in the MCP allowed to determine the MCP response to particles in this energy range. Moreover, a theoretical model allows to predict the response of MCP at even higher proton energies. This suggests that in this regime the MCP response is a slowly decreasing function of energy, consistently with the decrease of the deposited energy. These calibration data will enable particle spectra to be obtained in absolute terms over a broad energy range.
Two nucleon systems at m π ~ 450 MeV from lattice QCD
Orginos, Kostas; Parreño, Assumpta; Savage, Martin J.; ...
2015-12-23
Nucleon-nucleon systems are studied with lattice quantum chromodynamics at a pion mass ofmore » $$m_\\pi\\sim 450~{\\rm MeV}$$ in three spatial volumes using $$n_f=2+1$$ flavors of light quarks. At the quark masses employed in this work, the deuteron binding energy is calculated to be $$B_d = 14.4^{+3.2}_{-2.6} ~{\\rm MeV}$$, while the dineutron is bound by $$B_{nn} = 12.5^{+3.0}_{-5.0}~{\\rm MeV}$$. Over the range of energies that are studied, the S-wave scattering phase shifts calculated in the 1S0 and 3S1-3D1 channels are found to be similar to those in nature, and indicate repulsive short-range components of the interactions, consistent with phenomenological nucleon-nucleon interactions. In both channels, the phase shifts are determined at three energies that lie within the radius of convergence of the effective range expansion, allowing for constraints to be placed on the inverse scattering lengths and effective ranges. Thus, the extracted phase shifts allow for matching to nuclear effective field theories, from which low energy counterterms are extracted and issues of convergence are investigated. As part of the analysis, a detailed investigation of the single hadron sector is performed, enabling a precise determination of the violation of the Gell-Mann–Okubo mass relation.« less
Dai, Lei; Wang, Chi; Duan, Suping; ...
2015-08-10
Substorms generally inject tens to hundreds of keV electrons, but intense substorm electric fields have been shown to inject MeV electrons as well. An intriguing question is whether such MeVelectron injections can populate the outer radiation belt. Here we present observations of a substorm injection of MeV electrons into the inner magnetosphere. In the premidnight sector at L ~ 5.5, Van Allen Probes (Radiation Belt Storm Probes)-A observed a large dipolarization electric field (50 mV/m) over ~40 s and a dispersionless injection of electrons up to ~3 MeV. Pitch angle observations indicated betatron acceleration of MeV electrons at the dipolarizationmore » front. Corresponding signals of MeV electron injection were observed at LANL-GEO, THEMIS-D, and GOES at geosynchronous altitude. Through a series of dipolarizations, the injections increased the MeV electron phase space density by 1 order of magnitude in less than 3 h in the outer radiation belt (L > 4.8). Our observations provide evidence that deep injections can supply significant MeV electrons.« less
Effect of environmental temperature on shock absorption properties of running shoes.
Dib, Mansour Y; Smith, Jay; Bernhardt, Kathie A; Kaufman, Kenton R; Miles, Kevin A
2005-05-01
To determine the effect of temperature changes on the shock attenuation of 4 running shoe shock absorption systems. Prospective. Motion analysis laboratory. The shock attenuation of 4 different running shoes representing common shock absorption systems (Nike Air Triax, Asics Gel Nimbus IV, Adidas a3 cushioning, Adidas Supernova cushion) was measured at ambient temperatures of -20 degrees C, -10 degrees C, 0 degrees C, +10 degrees C, +20 degrees C, +30 degrees C, +40 degrees C, and +50 degrees C. Repeated-measures analysis of variance was used to determine differences between shoes. Shock attenuation as indicated by peak deceleration (g) measured by a mechanical impactor following ASTM Standard F1614-99. Shock attenuation decreased significantly with reduced temperature for each shoe tested. The Adidas a3 shoe exhibited significantly higher peak decelerations (lower shock attenuation) at cold temperatures compared with the other shoes. Cold ambient temperatures significantly reduce the shock attenuation of commonly used running shoes. These findings have important clinical implications for individuals training in extreme weather environments, particularly those with a history of lower limb overuse injuries.
Ndombo, P K; Ndze, V N; Mbarga, F D; Anderson, R; Acho, A; Ebua Chia, J; Njamnshi, A K; Rota, P A; Waku-Kouomou, D
2018-02-01
Measles is a highly infectious human viral disease caused by measles virus (MeV). An estimated 114 900 measles deaths occurred worldwide in 2014. There are currently eight clades (A-H) comprised 24 MeV genotypes. We sought to characterise MeVs among Central African Republic (CAR) refugees during the 2014 measles epidemic in Cameroon. Samples were collected from children <15 years with suspected measles infections in two refugee camps in the east region of Cameroon. Viral RNA was extracted directly from urine samples. RNA detection of MeV RNA was performed with real-time reverse transcription polymerase chain reaction (PCR) to amplify a 634 bp nucleotide fragment of the N gene. The sequence of the PCR product was obtained to determine the genotype. MeV RNA was detected in 25 out of 30 samples from suspected cases, and among the 25 positive samples, MeV sequences were obtained from 20. The MeV strains characterised were all genotype B3. The MeV strains from genotype B3 found in this outbreak were more similar to those circulating in Northern Cameroon in 2010-2011 than to MeV strains circulating in the CAR in 2011. Surveillance system should be improved to focus on refugees for early detection of and response to outbreaks.
Radiation damage study of thin YAG:Ce scintillator using low-energy protons
NASA Astrophysics Data System (ADS)
Novotný, P.; Linhart, V.
2017-07-01
Radiation hardness of a 50 μ m thin YAG:Ce scintillator in a form of dependence of a signal efficiency on 3.1 MeV proton fluence was measured and analysed using X-ray beam. The signal efficiency is a ratio of signals given by a CCD chip after and before radiation damage. The CCD chip was placed outside the primary beam because of its protection from damage which could be caused by radiation. Using simplified assumptions, the 3.1 MeV proton fluences were recalculated to: ṡ 150 MeV proton fluences with intention to estimate radiation damage of this sample under conditions at proton therapy centres during medical treatment, ṡ 150 MeV proton doses with intention to give a chance to compare radiation hardness of the studied sample with radiation hardness of other detectors used in medical physics, ṡ 1 MeV neutron equivalent fluences with intention to compare radiation hardness of the studied sample with properties of position sensitive silicon and diamond detectors used in nuclear and particle physics. The following results of our research were obtained. The signal efficiency of the studied sample varies slightly (± 3%) up to 3.1 MeV proton fluence of c. (4 - 8) × 1014 cm-2. This limit is equivalent to 150 MeV proton fluence of (5 - 9) × 1016 cm-2, 150 MeV proton dose of (350 - 600) kGy and 1 MeV neutron fluence of (1 - 2) × 1016 cm-2. Beyond the limit, the signal efficiency goes gradually down. Fifty percent decrease in the signal efficiency is reached around 3.1 MeV fluence of (1 - 2) × 1016 cm-2 which is equivalent to 150 MeV proton fluence of around 2 × 1018 cm-2, 150 MeV proton dose of around 15 MGy and 1 MeV neutron equivalent fluence of (4 - 8) × 1017 cm-2. In contrast with position sensitive silicon and diamond radiation detectors, the studied sample has at least two order of magnitude greater radiation resistance. Therefore, YAG:Ce scintillator is a suitable material for monitoring of primary beams of particles of ionizing radiation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tan, Lun C.; Shao, Xi; Malandraki, Olga E., E-mail: ltan@umd.edu
We have examined 29 large solar energetic particle (SEP) events with the peak proton intensity J {sub pp}(>60 MeV) > 1 pfu during solar cycle 23. The emphasis of our examination is put on a joint analysis of Ne/O and Fe/O data in the energy range (3–40 MeV nucleon{sup −1}) covered by Wind /Low-Energy Matrix Telescope and ACE /Solar Isotope Spectrometer sensors in order to differentiate between the Fe-poor and Fe-rich events that emerged from the coronal mass ejection driven shock acceleration process. An improved ion ratio calculation is carried out by rebinning ion intensity data into the form ofmore » equal bin widths in the logarithmic energy scale. Through the analysis we find that the variability of Ne/O and Fe/O ratios can be used to investigate the accelerating shock properties. In particular, the high-energy Ne/O ratio is well correlated with the source plasma temperature of SEPs.« less
NASA Astrophysics Data System (ADS)
Gadioli, E.; Cavinato, M.; Fabrici, E.; Gadioli Erba, E.; Birattari, C.; Mica, I.; Solia, S.; Steyn, G. F.; Förtsch, S. V.; Lawrie, J. J.; Nortier, F. M.; Stevens, T. G.; Connell, S. H.; Sellschop, J. P. F.; Cowley, A. A.
1999-08-01
The results of measured inclusive double differential cross section of α particles emitted in the interaction of 12C ions with 59Co and 93Nb at incident energies of 300 and 400 MeV are presented. The analysis of these data allows us to isolate the contributions of the different reaction mechanisms, thereby confirming previous conclusions of a comprehensive analysis of a large number of excitation function, forward recoil ranges and angular distributions of residues produced in the interaction of 12C with a target nucleus in the same mass range. In particular, the probabilities associated with α-particle reemission following incomplete fussion processes have been reaffirmed. Several refinements to the theoretical model proposed in earlier studies of the interaction of 12C with nuclei are presented.
Strong Evidence for Nucleon Resonances near 1900 MeV
NASA Astrophysics Data System (ADS)
Anisovich, A. V.; Burkert, V.; Hadžimehmedović, M.; Ireland, D. G.; Klempt, E.; Nikonov, V. A.; Omerović, R.; Osmanović, H.; Sarantsev, A. V.; Stahov, J.; Švarc, A.; Thoma, U.
2017-08-01
Data on the reaction γ p →K+Λ from the CLAS experiments are used to derive the leading multipoles, E0 +, M1 -, E1 +, and M1 +, from the production threshold to 2180 MeV in 24 slices of the invariant mass. The four multipoles are determined without any constraints. The multipoles are fitted using a multichannel L +P model that allows us to search for singularities and to extract the positions of poles on the complex energy plane in an almost model-independent method. The multipoles are also used as additional constraints in an energy-dependent analysis of a large body of pion and photoinduced reactions within the Bonn-Gatchina partial wave analysis. The study confirms the existence of poles due to nucleon resonances with spin parity JP=1 /2- , 1 /2+ , and 3 /2+ in the region at about 1.9 GeV.
Nuclear Resonance Fluorescence of U-235
DOE Office of Scientific and Technical Information (OSTI.GOV)
Warren, Glen A.; Caggiano, Joseph A.; Hensley, Walter K.
Nuclear resonance fluorescence is a physical process that provides an isotopic-specific signature that could be used for the identification and characterization of materials. The technique involves the detection of prompt discrete-energy photons emitted from a sample which is exposed to photons in the MeV energy range. Potential applications of the technique range from detection of high explosives to characterization of special nuclear materials. One isotope of significant interest is 235U. Pacific Northwest National Laboratory and Passport Systems have collaborated to conduct measurements to search for a nuclear resonance fluorescence response of 235U below 3 MeV using a 200 g samplemore » of highly enriched uranium. Nine 235U resonances between 1650 and 2010 keV were identified in the preliminary analysis. Analysis of the measurement data to determine the integrated cross sections of the resonances is in progress.« less
Statistical properties of the radiation belt seed population
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boyd, A. J.; Spence, H. E.; Huang, C. -L.
Here, we present a statistical analysis of phase space density data from the first 26 months of the Van Allen Probes mission. In particular, we investigate the relationship between the tens and hundreds of keV seed electrons and >1 MeV core radiation belt electron population. Using a cross-correlation analysis, we find that the seed and core populations are well correlated with a coefficient of ≈0.73 with a time lag of 10–15 h. We present evidence of a seed population threshold that is necessary for subsequent acceleration. The depth of penetration of the seed population determines the inner boundary of themore » acceleration process. However, we show that an enhanced seed population alone is not enough to produce acceleration in the higher energies, implying that the seed population of hundreds of keV electrons is only one of several conditions required for MeV electron radiation belt acceleration.« less
In-beam γ -ray spectroscopy studies of medium-spin states in the odd-odd nucleus Re 186
DOE Office of Scientific and Technical Information (OSTI.GOV)
Matters, D. A.; Kondev, F. G.; Aoi, N.
2017-07-01
Excited states in 186Re with spins up to J = 12~ were investigated in two separate experiments using 186W(d, 2n) reactions at beam energies of 12.5 MeV and 14.5 MeV. Two- and three-fold γ-ray coincidence data were collected using the CAESAR and CAGRA spectrometers, respectively, each composed of Compton-suppressed HpGe detectors. Analysis of the data revealed rotational bands built on several two-quasiparticle intrinsic states, including a long-lived Kπ = (8+) isomer. Configuration assignments were supported by an analysis of in-band properties, such as |gK - gR| values. The excitation energies of the observed intrinsic states were compared with results frommore » multiquasiparticle blocking calculations, based on the Lipkin-Nogami pairing approach, that included contributions from the residual proton-neutron interactions.« less
Statistical properties of the radiation belt seed population
Boyd, A. J.; Spence, H. E.; Huang, C. -L.; ...
2016-07-25
Here, we present a statistical analysis of phase space density data from the first 26 months of the Van Allen Probes mission. In particular, we investigate the relationship between the tens and hundreds of keV seed electrons and >1 MeV core radiation belt electron population. Using a cross-correlation analysis, we find that the seed and core populations are well correlated with a coefficient of ≈0.73 with a time lag of 10–15 h. We present evidence of a seed population threshold that is necessary for subsequent acceleration. The depth of penetration of the seed population determines the inner boundary of themore » acceleration process. However, we show that an enhanced seed population alone is not enough to produce acceleration in the higher energies, implying that the seed population of hundreds of keV electrons is only one of several conditions required for MeV electron radiation belt acceleration.« less
NASA Astrophysics Data System (ADS)
Dell'Aquila, D.; Acosta, L.; Auditore, L.; Cardella, G.; De Filippo, E.; De Luca, S.; Francalanza, L.; Gnoffo, B.; Lanzalone, G.; Lombardo, I.; Martorana, N. S.; Pagano, A.; Pagano, E. V.; Papa, M.; Pirrone, S.; Politi, G.; Quattrocchi, L.; Rizzo, F.; Rosato, E.; Russotto, P.; Trifirò, A.; Trimarchi, M.; Verde, G.; Vigilante, M.
2017-06-01
We describe the results of a new experiment aimed to investigate the possible existence of cluster structures in10Be and16C isotopes. They have been investigated at the FRIBs facility of INFN-LNS by means of an invariant mass analysis on correlated projectile breakup fragments carried out with the CHIMERA 4π detector. From the analysis of the6He+4He channel we found evidence of a new state in10Be at 13.5MeV excitation energy. Concerning16C, we investigated6He+10Be correlated fragments and we found a non-vanishing yield at about 20.5MeV in the corresponding excitation energy spectrum. Finally, we describe few details of a new experiment performed at the FRIBs facility where the CHIMERA detector was coupled to the FARCOS hodoscope, with the aim to improve the presently obtained results.
NASA Technical Reports Server (NTRS)
Swimm, Randall; Garrett, Henry B.; Jun, Insoo; Evans, Robin W.
2004-01-01
In this study we examine ten-minute omni-directional averages of energetic electron data measured by the Galileo spacecraft Energetic Particle Detector (EPD). Count rates from electron channels B1, DC2, and DC3 are evaluated using a power law model to yield estimates of the differential electron fluxes from 1 MeV to 11 MeV at distances between 8 and 51 Jupiter radii. Whereas the orbit of the Galileo spacecraft remained close to the rotational equatorial plane of Jupiter, the approximately 11 degree tilt of the magnetic axis of Jupiter relative to its rotational axis allowed the EPD instrument to sample high energy electrons at limited distances normal to the magnetic equatorial plane. We present a Fourier analysis of the semi-diurnal variation of electron fluxes with longitude.
Naville, Magali; Gautheret, Daniel
2010-01-01
Bacterial transcription attenuation occurs through a variety of cis-regulatory elements that control gene expression in response to a wide range of signals. The signal-sensing structures in attenuators are so diverse and rapidly evolving that only a small fraction have been properly annotated and characterized to date. Here we apply a broad-spectrum detection tool in order to achieve a more complete view of the transcriptional attenuation complement of key bacterial species. Our protocol seeks gene families with an unusual frequency of 5' terminators found across multiple species. Many of the detected attenuators are part of annotated elements, such as riboswitches or T-boxes, which often operate through transcriptional attenuation. However, a significant fraction of candidates were not previously characterized in spite of their unmistakable footprint. We further characterized some of these new elements using sequence and secondary structure analysis. We also present elements that may control the expression of several non-homologous genes, suggesting co-transcription and response to common signals. An important class of such elements, which we called mobile attenuators, is provided by 3' terminators of insertion sequences or prophages that may be exapted as 5' regulators when inserted directly upstream of a cellular gene. We show here that attenuators involve a complex landscape of signal-detection structures spanning the entire bacterial domain. We discuss possible scenarios through which these diverse 5' regulatory structures may arise or evolve.
The nuclear spin response to intermediate energy protons
NASA Astrophysics Data System (ADS)
Baker, F. T.; Bimbot, L.; Castel, B.; Fergerson, R. W.; Glashausser, C.; Green, A.; Hausser, O.; Hicks, K.; Jones, K.; Miller, C. A.; Nanda, S. K.; Smith, R. D.; Vetterli, M.; Wambach, J.; Abegg, R.; Beatty, D.; Cupps, V.; Djalali, C.; Henderson, R.; Jackson, K. P.; Jeppeson, R.; Lisantti, J.; Morlet, M.; Sawafta, R.; Unkelbach, W.; Willis, A.; Yen, S.
1990-03-01
Measurements of the spin-flip probability Snn for inclusive inelastic proton scattering around 300 MeV from nuclei between 12C and 90Zr show that an enhanced spin response near 40 MeV excitation at q ∼ 100 MeV/ c is a general feature of nuclear structure. Data for 40Ca at 800 MeV confirm that the enhancement is not a peculiarity of 300 MeV scattering. In addition, measurements in 44Ca up to 75 MeV show that the enhancement cannot be attributed solely to a relatively narrow resonance. Continuum RPA calculations suggest that the enhancement is due to the exhaustion of most S = 0 strength at lower energy and a shift of S = 1 strength to higher energy.
Spins of complex fragments in binary reactions within a dinuclear system model
NASA Astrophysics Data System (ADS)
Paşca, H.; Kalandarov, Sh. A.; Adamian, G. G.; Antonenko, N. V.
2017-10-01
The average angular momenta and widths of the spin distributions of reaction products are calculated within the dinuclear system model. The thermal excitation of rotational bearing modes is considered in the dinuclear system. The calculated fragment spins (γ multiplicities) and their variances in the reactions 20Ne (166 MeV) + 63Cu, 40Ar (280 MeV) + 58Ni, 20Ne (175 MeV) + natAg, 40Ar (237 MeV) + 89Y, 40Ar (288 and 340 MeV) + Ag,109107, and 16O (100 MeV) + 58Ni are compared with the available experimental data. The influence of the entrance channel charge (mass) asymmetry and bombarding energy on the characteristics of spin distribution is studied.
Thakkar, Vidhi D; Cox, Robert M; Sawatsky, Bevan; da Fontoura Budaszewski, Renata; Sourimant, Julien; Wabbel, Katrin; Makhsous, Negar; Greninger, Alexander L; von Messling, Veronika; Plemper, Richard K
2018-04-15
The paramyxovirus replication machinery comprises the viral large (L) protein and phosphoprotein (P-protein) in addition to the nucleocapsid (N) protein, which encapsidates the single-stranded RNA genome. Common to paramyxovirus N proteins is a C-terminal tail (Ntail). The mechanistic role and relevance for virus replication of the structurally disordered central Ntail section are unknown. Focusing initially on members of the Morbillivirus genus, a series of measles virus (MeV) and canine distemper virus (CDV) N proteins were generated with internal deletions in the unstructured tail section. N proteins with large tail truncations remained bioactive in mono- and polycistronic minireplicon assays and supported efficient replication of recombinant viruses. Bioactivity of Ntail mutants extended to N proteins derived from highly pathogenic Nipah virus. To probe an effect of Ntail truncations on viral pathogenesis, recombinant CDVs were analyzed in a lethal CDV/ferret model of morbillivirus disease. The recombinant viruses displayed different stages of attenuation ranging from ameliorated clinical symptoms to complete survival of infected animals, depending on the molecular nature of the Ntail truncation. Reinfection of surviving animals with pathogenic CDV revealed robust protection against a lethal challenge. The highly attenuated virus was genetically stable after ex vivo passaging and recovery from infected animals. Mechanistically, gradual viral attenuation coincided with stepwise altered viral transcriptase activity in infected cells. These results identify the central Ntail section as a determinant for viral pathogenesis and establish a novel platform to engineer gradual virus attenuation for next-generation paramyxovirus vaccine design. IMPORTANCE Investigating the role of the paramyxovirus N protein tail domain (Ntail) in virus replication, we demonstrated in this study that the structurally disordered central Ntail region is a determinant for viral pathogenesis. We show that internal deletions in this Ntail region of up to 55 amino acids in length are compatible with efficient replication of recombinant viruses in cell culture but result in gradual viral attenuation in a lethal canine distemper virus (CDV)/ferret model. Mechanistically, we demonstrate a role of the intact Ntail region in the regulation of viral transcriptase activity. Recombinant viruses with Ntail truncations induce protective immunity against lethal challenge of ferrets with pathogenic CDV. This identification of the unstructured central Ntail domain as a nonessential paramyxovirus pathogenesis factor establishes a foundation for harnessing Ntail truncations for vaccine engineering against emerging and reemerging members of the paramyxovirus family. Copyright © 2018 American Society for Microbiology.
NASA Astrophysics Data System (ADS)
Harayama, I.; Nagashima, K.; Hirose, Y.; Matsuzaki, H.; Sekiba, D.
2016-10-01
We have developed a compact ΔE-E telescope elastic recoil detection analysis (ERDA) system, for the first time at Micro Analysis Laboratory, Tandem Accelerator (MALT) in the University of Tokyo, which consists of a gas ionization chamber and solid state detector (SSD) for the quantitative analysis of light elements. The gas ionization chamber is designed to identify the recoils of O and N from metal oxynitrides thin films irradiated with 40 MeV 35Cl7+. The length of the electrodes along the beam direction is 50 mm optimized to sufficiently separate energy loss of O and N recoils in P10 gas at 6.0 × 103 Pa. The performance of the gas ionization chamber was examined by comparing the ERDA results on the SrTaO2N thin films with semi-empirical simulation and the chemical compositions previously determined by nuclear reaction analysis (NRA) and Rutherford backscattering spectrometry (RBS). We also confirmed availability of the gas ionization chamber for identifying not only the recoils of O and N but also those of lithium, carbon and fluorine.
Materials science education: ion beam modification and analysis of materials
NASA Astrophysics Data System (ADS)
Zimmerman, Robert; Muntele, Claudiu; Ila, Daryush
2012-08-01
The Center for Irradiation of Materials (CIM) at Alabama A&M University (http://cim.aamu.edu) was established in 1990 to serve the University in its research, education and services to the need of the local community and industry. CIM irradiation capabilities are oriented around two tandem-type ion accelerators with seven beam lines providing high-resolution Rutherford backscattering spectrometry, MeV focus ion beam, high-energy ion implantation and irradiation damage studies, particle-induced X-ray emission, particle-induced gamma emission and ion-induced nuclear reaction analysis in addition to fully automated ion channeling. One of the two tandem ion accelerators is designed to produce high-flux ion beam for MeV ion implantation and ion irradiation damage studies. The facility is well equipped with a variety of surface analysis systems, such as SEM, ESCA, as well as scanning micro-Raman analysis, UV-VIS Spectrometry, luminescence spectroscopy, thermal conductivity, electrical conductivity, IV/CV systems, mechanical test systems, AFM, FTIR, voltammetry analysis as well as low-energy implanters, ion beam-assisted deposition and MBE systems. In this presentation, we will demonstrate how the facility is used in material science education, as well as providing services to university, government and industry researches.
NASA Astrophysics Data System (ADS)
Rout, Bibhudutta; Dhoubhadel, Mangal S.; Poudel, Prakash R.; Kummari, Venkata C.; Lakshantha, Wickramaarachchige J.; Manuel, Jack E.; Bohara, Gyanendra; Szilasi, Szabolcs Z.; Glass, Gary A.; McDaniel, Floyd D.
2014-02-01
The University of North Texas (UNT) Ion Beam Modification and Analysis Laboratory (IBMAL) has four particle accelerators including a National Electrostatics Corporation (NEC) 9SDH-2 3 MV tandem Pelletron, a NEC 9SH 3 MV single-ended Pelletron, and a 200 kV Cockcroft-Walton. A fourth HVEC AK 2.5 MV Van de Graaff accelerator is presently being refurbished as an educational training facility. These accelerators can produce and accelerate almost any ion in the periodic table at energies from a few keV to tens of MeV. They are used to modify materials by ion implantation and to analyze materials by numerous atomic and nuclear physics techniques. The NEC 9SH accelerator was recently installed in the IBMAL and subsequently upgraded with the addition of a capacitive-liner and terminal potential stabilization system to reduce ion energy spread and therefore improve spatial resolution of the probing ion beam to hundreds of nanometers. Research involves materials modification and synthesis by ion implantation for photonic, electronic, and magnetic applications, micro-fabrication by high energy (MeV) ion beam lithography, microanalysis of biomedical and semiconductor materials, development of highenergy ion nanoprobe focusing systems, and educational and outreach activities. An overview of the IBMAL facilities and some of the current research projects are discussed.
Number distribution of emitted electrons by MeV H+ impact on carbon
NASA Astrophysics Data System (ADS)
Ogawa, H.; Koyanagi, Y.; Hongo, N.; Ishii, K.; Kaneko, T.
2017-09-01
The statistical distributions of the number of the forward- and backward-emitted secondary electrons (SE's) from a thin carbon foil have been measured in coincidence with foil-transmitted H+ ions of 0.5-3.0 MeV in every 0.5 MeV step. The measured SE energy spectra were fitted by assuming a Pólya distribution for the simultaneous n-SE emission probabilities. For our previous data with a couple of the carbon foils with different thicknesses, a similar analysis has been carried out. As a result, it was found that the measured spectra could be reproduced as well as by an analysis without placing any restriction on the emission probabilities both for the forward and backward SE emission. The obtained b-parameter of the Pólya distribution, which is a measure of the deviation from a Poisson distribution due to the cascade multiplication by high energy internal SE's, increases monotonically with the incident energy of proton beams. On the other hand, a clear foil-thickness dependence is not observed for the b-parameter. A theoretical model which could reproduced the magnitude of the b-parameter for the SE energy spectra obtained with thick Au, Cu and Al targets is found to overestimates our values for thin carbon foils significantly. Another model calculation is found to reproduce our b-values very well.
Conceptual study of a heavy-ion-ERDA spectrometer for energies below 6 MeV
NASA Astrophysics Data System (ADS)
Julin, Jaakko; Sajavaara, Timo
2017-09-01
Elastic recoil detection analysis (ERDA) is a well established technique and it offers unique capabilities in thin film analysis. Simultaneous detection and depth profiling of all elements, including hydrogen, is possible only with time-of-flight ERDA. Bragg ionization chambers or ΔE - E detectors can also be used to identify the recoiling element if sufficiently high energies are used. The chief limitations of time-of-flight ERDA are the beam induced sample damage and the requirement of a relatively large accelerator. In this paper we propose a detector setup, which could be used with 3 MeV to 6 MeV medium heavy beams from either a single ended accelerator (40Ar) or from a tandem accelerator (39K). The detector setup consists of two timing detectors and a gas ionization chamber energy detector. Compared to use of very heavy low energy ions the hydrogen recoils with this beam have sufficient energy to be detected with current gas ionization chamber energy detector. To reduce the beam induced damage the proposed detector setup covers a solid angle larger than 1 msr, roughly an order of magnitude improvement over most time-of-flight ERDA setups. The setup could be used together with a small accelerator to be used for light element analysis of approximately 50 nm films. The concept is tested with 39K beam from a 1.7 MV Pelletron tandem accelerator with the Jyväskylä ToF-ERDA setup. In addition to the measurements effects related to low energies and increase in the solid angle are simulated with Monte Carlo methods.
Taussky, P; Kallmes, D F; Cloft, H
2012-05-01
Higher packing attenuation of coils in cerebral aneurysms is associated with a decreased recurrence rate. However, geometric relationships suggest that an additional coil may have very little effect on packing attenuation as aneurysm size increases. We mathematically evaluated the relationship between aneurysm size and incremental packing attenuation for coils currently available.
NASA Technical Reports Server (NTRS)
Kuzin, Alexander V.; Holmes, Michael L.; Behrouzjou, Roxana; Trumper, David L.
1994-01-01
The results of the analysis of the achievable disturbance attenuation to get an Angstrom motion control resolution and macroscopic travel in a precision magnetically-suspended motion control system are presented in this paper. Noise sources in the transducers, electronics, and mechanical vibrations are used to develop the control design.
High-dose MeV electron irradiation of Si-SiO2 structures implanted with high doses Si+
NASA Astrophysics Data System (ADS)
Kaschieva, S.; Angelov, Ch; Dmitriev, S. N.
2018-03-01
The influence was studied of 22-MeV electron irradiation on Si-SiO2 structures implanted with high-fluence Si+ ions. Our earlier works demonstrated that Si redistribution is observed in Si+-ion-implanted Si-SiO2 structures (after MeV electron irradiation) only in the case when ion implantation is carried out with a higher fluence (1016 cm-2). We focused our attention on the interaction of high-dose MeV electron irradiation (6.0×1016 cm-2) with n-Si-SiO2 structures implanted with Si+ ions (fluence 5.4×1016 cm-2 of the same order magnitude). The redistribution of both oxygen and silicon atoms in the implanted Si-SiO2 samples after MeV electron irradiation was studied by Rutherford back-scattering (RBS) spectroscopy in combination with a channeling technique (RBS/C). Our results demonstrated that the redistribution of oxygen and silicon atoms in the implanted samples reaches saturation after these high doses of MeV electron irradiation. The transformation of amorphous SiO2 surface into crystalline Si nanostructures (after MeV electron irradiation) was evidenced by atomic force microscopy (AFM). Silicon nanocrystals are formed on the SiO2 surface after MeV electron irradiation. The shape and number of the Si nanocrystals on the SiO2 surface depend on the MeV electron irradiation, while their size increases with the dose. The mean Si nanocrystals height is 16-20 nm after irradiation with MeV electrons at the dose of 6.0×1016 cm-2.
Isospin symmetry in nucleon scattering from 6Li and 12C at 280 MeV
NASA Astrophysics Data System (ADS)
Mildenberger, J.; Häusser, O.; Jeppesen, R. G.; Larson, B.; Pointon, B.; Trudel, A.; Henderson, R.; Hicks, K.; Jackson, K. P.; Miller, A.; Vetterli, M.; Yen, S.; Alford, W. P.; Ćeller, A.; Helmer, R.
1990-08-01
Tests of isospin symmetry in (n,p), (p,p'), and (p,n) reactions at 280 MeV populating the T=1 isospin triads in A=6 and A=12 nuclei have been performed. Distorted-wave impulse approximation (DWIA) calculations for the A=12 triad where the known ft asymmetry is included in the analysis show good agreement with experimental (n,p) and (p,p') data. Angular distributions for 6Li(n,p) and 6Li(p,p') cross sections differ significantly at finite values of momentum transfer (q) and do not agree with DWIA calculations. However, this discrepancy may become negligible upon extrapolation to q=0.
NASA Astrophysics Data System (ADS)
Watanabe, Y.; Abe, S.
2014-06-01
Terrestrial neutron-induced soft errors in MOSFETs from a 65 nm down to a 25 nm design rule are analyzed by means of multi-scale Monte Carlo simulation using the PHITS-HyENEXSS code system. Nuclear reaction models implemented in PHITS code are validated by comparisons with experimental data. From the analysis of calculated soft error rates, it is clarified that secondary He and H ions provide a major impact on soft errors with decreasing critical charge. It is also found that the high energy component from 10 MeV up to several hundreds of MeV in secondary cosmic-ray neutrons has the most significant source of soft errors regardless of design rule.
Analysis of 4He+40Ca and 4He+44Ti scattering using different optical model potentials
NASA Astrophysics Data System (ADS)
Ibraheem, Awad A.
2016-09-01
Elastic scattering of 4He+40Ca and 4He+44Ti reactions at backward angles has been analyzed using two differentmodels, microscopic and semimicroscopic folding potentials. The derived real potentials supplemented with phenomenological Woods-Saxon imaginary potentials, provide good agreement with the experimental data at energy E c.m. = 21.8 MeV without need to renormalize the potentials. Coupledchannels calculations are used to extract the inelastic scattering cross section to the low-lying state 2+ (1.083 MeV) of 44Ti. The deformation length is obtained and compared with the electromagnetic measurement values as well as those obtained from previous studies.
NASA Astrophysics Data System (ADS)
Gurbich, A. F.; Bokhovko, M. V.
2018-04-01
The alpha elastic scattering cross-sections for Ni, Cu, and Y were measured at the energies above the onset of the non-Rutherford scattering. The obtained experimental data along with data from literature were incorporated into the theoretical analysis in the framework of the optical model. The optimization of the model parameters provided a basis for the calculations of the differential cross-sections for Z = 28-38 elements in the energy range up to 10 MeV. The obtained cross sections were made available for common use through the SigmaCalc web site at http://sigmacalc.iate.obninsk.ru/.
Observation of interlayer excitons in MoSe2 single crystals
NASA Astrophysics Data System (ADS)
Horng, Jason; Stroucken, Tineke; Zhang, Long; Paik, Eunice Y.; Deng, Hui; Koch, Stephan W.
2018-06-01
Interlayer excitons with direct optical transitions are observed coexisting with intralayer excitons in the same K valleys in bilayer, few-layer, and bulk MoSe2 single crystals by confocal reflection contrast spectroscopy. Quantitative analysis using the Dirac-Bloch equations provides unambiguous state assignment of all the measured resonances. The interlayer excitons in bilayer MoSe2 have a large binding energy of 153 meV and a narrow linewidth of 20 meV. Their spectral weight is comparable to the commonly studied higher-order intralayer excitons. At the same time, the interlayer excitons are characterized by distinct transition energies and permanent dipole moments, providing a promising high temperature and optically accessible platform for dipolar exciton physics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Terashima, S.; Sakaguchi, H.; Takeda, H.
Cross sections and analyzing powers for proton elastic scattering from {sup 116,118,120,122,124}Sn at 295 MeV have been measured for a momentum transfer of up to about 3.5 fm{sup -1} to deduce systematic changes of the neutron density distribution. We tuned the relativistic Love-Franey interaction to explain the proton elastic scattering of a nucleus whose density distribution is well known. Then, we applied this interaction to deduce the neutron density distributions of tin isotopes. The result of our analysis shows the clear systematic behavior of a gradual increase in the neutron skin thickness of tin isotopes with mass number.
Ion beam promoted lithium absorption in glassy polymeric carbon
NASA Astrophysics Data System (ADS)
Ila, D.; Zimmerman, R. L.; Jenkins, G. M.; Maleki, H.; Poker, D. B.
1995-12-01
Glassy Polymeric Carbon (GPC) samples prepared from a precursor possess accessible pore volume that depends on the heat treatment temperature. We have shown that lithium percolates without diffusion into the accessible pores of GPC samples immersed in a molten lithium salt bath at 700°C. Ion bombardment with 10 MeV Au atoms increases the total pore volume available for lithium occupation even for samples normally impermeable to lithium. The lithium concentration depth profile is measured using Li7(p,2α) nuclear reaction analysis. We will report on lithium percolation into GPC prepared at temperatures between 500°C and 1000°C and activated by a 10 MeV gold ion bombardment.
High-energy γ rays resulting from low-energy nuclear reactions in light nuclei
NASA Astrophysics Data System (ADS)
Rose, Paul B.; Erickson, Anna S.
2018-06-01
Products resulting from 3.02 MeV deuterons incident on a natural boron target have been investigated by way of γ -ray spectroscopy and activation analysis. This study uses observed γ rays and cascades to deduce the populated states from the reaction products. Die-away measurements are included to investigate the built-up activation from the target and compared with tabulated half-lives to further understand the plethora of reactions taking place. Many of the observed γ rays, such as 15.1 MeV, result from the formation of excited states of 12C, while others are secondary and tertiary processes from α breakup resulting in 8Be.
NASA Astrophysics Data System (ADS)
Sood, R. K.; Waldron, L.; Rochester, G. K.; Sumner, T. J.; Frye, G.; Jenkins, T.; Staubert, R.; Kendziorra, E.; Ubertini, P.; Bazzano, A.
1992-08-01
Analysis of the data obtained from two flights of a balloonborne gamma-ray detector to observe SN 1987A was completed. The detector, which included a spark chamber to determine the arrival directions of the photons, was sensitive in the energy range 50-500 MeV. The 95 percent confidence upper limit to the flux on day 55 after the explosion has been established to be 1.1 x 10 exp -5 photons/sq cm/s and on day 407 to be 3.4 x 10 exp -5 photons/sq cm/s. These limits are compared with various theoretical predictions.
Photoacoustic signal attenuation analysis for the assessment of thin layers thickness in paintings
NASA Astrophysics Data System (ADS)
Tserevelakis, George J.; Dal Fovo, Alice; Melessanaki, Krystalia; Fontana, Raffaella; Zacharakis, Giannis
2018-03-01
This study introduces a novel method for the thickness estimation of thin paint layers in works of art, based on photoacoustic signal attenuation analysis (PAcSAA). Ad hoc designed samples with acrylic paint layers (Primary Red Magenta, Cadmium Yellow, Ultramarine Blue) of various thicknesses on glass substrates were realized for the specific application. After characterization by Optical Coherence Tomography imaging, samples were irradiated at the back side using low energy nanosecond laser pulses of 532 nm wavelength. Photoacoustic waves undergo a frequency-dependent exponential attenuation through the paint layer, before being detected by a broadband ultrasonic transducer. Frequency analysis of the recorded time-domain signals allows for the estimation of the average transmitted frequency function, which shows an exponential decay with the layer thickness. Ultrasonic attenuation models were obtained for each pigment and used to fit the data acquired on an inhomogeneous painted mock-up simulating a real canvas painting. Thickness evaluation through PAcSAA resulted in excellent agreement with cross-section analysis with a conventional brightfield microscope. The results of the current study demonstrate the potential of the proposed PAcSAA method for the non-destructive stratigraphic analysis of painted artworks.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Salvadori, P.
1962-10-31
The proton (p ) and gamma energy and angular distributions from the elastic (Compton) interaction p + gamma -- p + gamma are calculated. The results are tabulated for 25-Mev gamma increments, from 300 to 1500 Mev. (T.F.H.)
USDA-ARS?s Scientific Manuscript database
Prompt-gamma neutron activation (PGNA) analysis is used for the non-invasive measurement of human body composition. Advancements in portable, compact neutron generator design have made those devices attractive as neutron sources. Two distinct generators are available: D-D with 2.5 MeV and D-T with...
2017-06-15
the GaSb valance band edge, in agreement with values deduced recently from lifetime measurements and analysis [Aytac et al . Phys. Rev. Appl., 5...meV below the GaSb valance band edge, in agreement with values deduced recently from lifetime mea- surements and analysis [Aytac et al . Phys. Rev
Lundgren, Anna; Jertborn, Marianne; Svennerholm, Ann-Mari
2016-06-08
We have evaluated the capacity of an oral multivalent enterotoxigenic Escherichia coli (ETEC) vaccine (MEV) to induce mucosal immunological memory. MEV consists of four inactivated E. coli strains over-expressing the major colonization factors (CFs) CFA/I, CS3, CS5 and CS6 and the LTB-related toxoid LCTBA. Memory responses were analyzed by comparing the magnitudes and kinetics of intestine-derived antibody-secreting cell responses to a single dose of MEV in three groups of adult Swedish volunteers (n=16-19 subjects per group) in a Phase I trial: non-immunized controls (I) and subjects who in a previous Phase I trial 13-23 months earlier had received two biweekly doses of MEV (II) or MEV+double mutant LT (dmLT) adjuvant (III). Responses against CFs and LTB were analyzed in antibodies in lymphocyte secretions (ALS) of blood mononuclear cells collected before (day 0) and 4/5 and 7 days after immunization. Specific circulating memory B cells present at the time of the single dose vaccination were also studied to determine if such cells may reflect mucosal memory. Considerably higher and significantly more frequent IgA ALS responses against all CFs and LTB were induced by the single vaccine dose in the previously immunized than in non-immunized volunteers. Furthermore, peak IgA ALS responses against all antigens were observed on days 4/5 in most of the previously immunized subjects whereas only a few previously non-vaccinated individuals responded before day 7. Priming with adjuvant did not influence memory responses. Circulating vaccine specific IgA memory B cells were not detected, whereas anti-toxin IgG memory B cells were identified 13-23 months after priming vaccination. We conclude that MEV induces functional mucosal immunological memory which remains at least 1-2 years. Furthermore, our results support that analysis of antibody-secreting cell responses after booster vaccination may be a useful approach to evaluate longstanding mucosal immunological memory in humans. ISRCTN27096290. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
NASA Astrophysics Data System (ADS)
Adlarson, P.; Augustyniak, W.; Bardan, W.; Bashkanov, M.; Bergmann, F. S.; Berłowski, M.; Bondar, A.; Büscher, M.; Calén, H.; Ciepał, I.; Clement, H.; Czerwiński, E.; Demmich, K.; Engels, R.; Erven, A.; Erven, W.; Eyrich, W.; Fedorets, P.; Föhl, K.; Fransson, K.; Goldenbaum, F.; Goswami, A.; Grigoryev, K.; Gullström, C.-O.; Heijkenskjöld, L.; Hejny, V.; Hüsken, N.; Jarczyk, L.; Johansson, T.; Kamys, B.; Kemmerling, G.; Khatri, G.; Khoukaz, A.; Khreptak, A.; Kirillov, D. A.; Kistryn, S.; Kleines, H.; Kłos, B.; Krzemień, W.; Kulessa, P.; Kupść, A.; Kuzmin, A.; Lalwani, K.; Lersch, D.; Lorentz, B.; Magiera, A.; Maier, R.; Marciniewski, P.; Mariański, B.; Morsch, H.-P.; Moskal, P.; Ohm, H.; Parol, W.; Perez del Rio, E.; Piskunov, N. M.; Prasuhn, D.; Pszczel, D.; Pysz, K.; Pyszniak, A.; Ritman, J.; Roy, A.; Rudy, Z.; Rundel, O.; Sawant, S.; Schadmand, S.; Schätti-Ozerianska, I.; Sefzick, T.; Serdyuk, V.; Shwartz, B.; Sitterberg, K.; Skorodko, T.; Skurzok, M.; Smyrski, J.; Sopov, V.; Stassen, R.; Stepaniak, J.; Stephan, E.; Sterzenbach, G.; Stockhorst, H.; Ströher, H.; Szczurek, A.; Trzciński, A.; Wolke, M.; Wrońska, A.; Wüstner, P.; Yamamoto, A.; Zabierowski, J.; Zieliński, M. J.; Złomańczuk, J.; Żuprański, P.; Żurek, M.; Wilkin, C.; WASA-at-COSY Collaboration
2018-07-01
New data on both total and differential cross sections of the production of η mesons in proton-deuteron fusion to 3He η in the excess energy region 13.6MeV ≤Qη ≤ 80.9MeV are presented. These data have been obtained with the WASA-at-COSY detector setup located at the Forschungszentrum Jülich, using a proton beam at 15 different beam momenta between pp = 1.60GeV / c and pp = 1.74GeV / c. While significant structure of the total cross section is observed in the energy region 20MeV ≲Qη ≲ 60MeV, a previously reported sharp variation around Qη ≈ 50MeV cannot be confirmed. Angular distributions show the typical forward-peaking that was noted earlier. For the first time, it is possible to study the development of these angular distributions with rising excess energy over a wide interval.
NASA Astrophysics Data System (ADS)
Paneta, V.; Kokkoris, M.; Lagoyannis, A.; Preketes-Sigalas, K.
2017-09-01
The present work aims at contributing to the field of Ion Beam Analysis by providing a set of standard, high-accuracy nuclear resonance reaction data points to be used for accelerator energy calibration up to 4.6 MeV, more specifically with the use of the 27Al(p,γ), 13C(p,γ), 12C(p,p0) and 32S(p,p‧γ) resonant reactions, as a result of a comprehensive investigation in two different laboratories. The use of resonances at higher energies, namely up to 6 MeV, is also discussed. The measurements have been performed at two different electrostatic accelerators, namely at the 5.5 MV HV TN-11 of NCSR "Demokritos", Greece, and at the 5 MV 15SDH-2 Pelletron Tandem accelerator at Uppsala University in Uppsala, Sweden. Common points were used to normalize and validate the data. The possible use of the 16O(p,p0) resonance at 3.47 MeV is also discussed and analyzed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Delbar, T.; Gregoire, G.; Paic, G.
1978-09-01
Angular distributions for ..cap alpha.. particle elastic scattering by /sup 40,44/Ca and excitation of the 3.73 MeV 3/sup -/ collective state of /sup 40/Ca were measured for incident energies ranging from 40 to 62 MeV. An extensive optical model analysis of these elastic scattering cross sections and other available data, using squared Woods-Saxon form factors, results in potentials with fixed geometry for both real and imaginary parts and depths with smooth energy behavior over a broad incident energy range. These results are discussed in the frame of the semi-classical approximation developed by Brink and Takigawa. The sensitiveness of the calculatedmore » elastic scattering cross sections to the real part of the potentials as a function of the projectile-target distance has been investigated by means of a notch test. Distorted-wave Born-approximtion calculations for the excitation of the 3.73 MeV 3/sup -/ state of /sup 40/Ca are presented.« less
Identification and imaging of modern paints using Secondary Ion Mass Spectrometry with MeV ions
NASA Astrophysics Data System (ADS)
Bogdanović Radović, Iva; Siketić, Zdravko; Jembrih-Simbürger, Dubravka; Marković, Nikola; Anghelone, Marta; Stoytschew, Valentin; Jakšić, Milko
2017-09-01
Secondary Ion Mass Spectrometry using MeV ion excitation was applied to analyse modern paint materials containing synthetic organic pigments and binders. It was demonstrated that synthetic organic pigments and binder components with molecular masses in the m/z range from 1 to 1200 could be identified in different paint samples with a high efficiency and in a single measurement. Different ways of mounting of mostly insulating paint samples were tested prior to the analysis in order to achieve the highest possible yield of pigment main molecular ions. As Time-of-Flight mass spectrometer for MeV Secondary Ion Mass Spectrometry is attached to the heavy ion microprobe, molecular imaging on cross-sections of small paint fragments was performed using focused ions. Due to the fact that molecules are extracted from the uppermost layer of the sample and to avoid surface contamination, the paint samples were not embedded in the resin as is usually done when imaging of paint samples using different techniques in the field of cultural heritage.
Yasui, Yoshihiro; Mori, Yoshio; Adachi, Hirokazu; Kobayashi, Shinichi; Yamashita, Teruo; Minagawa, Hiroko
2014-01-01
Between July 2012 and March 2013, a total of 133 clinical specimens from 47 patients suspected of having measles were collected for virological surveillance in Aichi Prefecture, Japan. Facing the rubella epidemic, the reverse transcription (RT)-PCR protocol for measles virus (MeV) was modified to simultaneously detect rubella virus (RUBV) in these clinical specimens. As a result, 30 specimens from 15 patients were positive for RUBV and 8 specimens from 3 patients were positive for MeV. The RUBV genotype analysis for the samples from 13 patients revealed 12 samples as 2B and 1 sample as 1E. The results provided additional evidence for the difficulty in the diagnosis of exanthematous diseases based on clinical manifestations alone and the necessity of virological diagnosis to maintain the accuracy of case-based surveillance. Furthermore, the results indicated that the modified RT-PCR protocol could be useful as a routine procedure to simultaneously detect MeV and RUBV in clinical specimens of patients suspected of having exanthematous disease caused by these viruses.
Ion beam modification of zinc white pigment characterized by ex situ and in situ μ-Raman and XPS
NASA Astrophysics Data System (ADS)
Beck, L.; Gutiérrez, P. C.; Miro, S.; Miserque, F.
2017-10-01
Zinc oxide, known as zinc white, is one of the principal white pigments developed in the 18th century and was used by the Impressionist painters. ZnO as artists' pigment has occasionally been characterized by X-ray and ion beam techniques, but these studies are limited by the potential for visible radiation effect. Ion beam modifications of zinc oxide have extensively been investigated, but mainly for electronic and industrial applications. In this paper, we focus our investigation on ion beam modification of ZnO used as pigment. Two irradiation conditions have been used: an external 3 MeV proton micro-beam representative of PIXE analysis and 2 MeV H+ and 1.2 MeV Au + beams in vacuum to investigate irradiation modifications in electronic and nuclear energy loss regimes. Ion beam modification was characterized by ex situ and in situ micro-Raman spectrometry and XPS. The results shows that IBA of zinc white can be carried out safely in historical paintings with low current and dose.
NASA Astrophysics Data System (ADS)
Tanaka, J.; Kanungo, R.; Alcorta, M.; Aoi, N.; Bidaman, H.; Burbadge, C.; Christian, G.; Cruz, S.; Davids, B.; Diaz Varela, A.; Even, J.; Hackman, G.; Harakeh, M. N.; Henderson, J.; Ishimoto, S.; Kaur, S.; Keefe, M.; Krücken, R.; Leach, K. G.; Lighthall, J.; Padilla Rodal, E.; Randhawa, J. S.; Ruotsalainen, P.; Sanetullaev, A.; Smith, J. K.; Workman, O.; Tanihata, I.
2017-11-01
Proton inelastic scattering off a neutron halo nucleus, 11Li, has been studied in inverse kinematics at the IRIS facility at TRIUMF. The aim was to establish a soft dipole resonance and to obtain its dipole strength. Using a high quality 66 MeV 11Li beam, a strongly populated excited state in 11Li was observed at Ex = 0.80 ± 0.02 MeV with a width of Γ = 1.15 ± 0.06 MeV. A DWBA (distorted-wave Born approximation) analysis of the measured differential cross section with isoscalar macroscopic form factors leads us to conclude that this observed state is excited in an electric dipole (E1) transition. Under the assumption of isoscalar E1 transitions, the strength is evaluated to be extremely large amounting to 30 ∼ 296 Weisskopf units, exhausting 2.2% ∼ 21% of the isoscalar E1 energy-weighted sum rule (EWSR) value. The large observed strength originates from the halo and is consistent with the simple di-neutron model of 11Li halo.
Proton upsets in LSI memories in space
NASA Technical Reports Server (NTRS)
Mcnulty, P. J.; Wyatt, R. C.; Filz, R. C.; Rothwell, P. L.; Farrell, G. E.
1980-01-01
Two types of large scale integrated dynamic random access memory devices were tested and found to be subject to soft errors when exposed to protons incident at energies between 18 and 130 MeV. These errors are shown to differ significantly from those induced in the same devices by alphas from an Am-241 source. There is considerable variation among devices in their sensitivity to proton-induced soft errors, even among devices of the same type. For protons incident at 130 MeV, the soft error cross sections measured in these experiments varied from 10 to the -8th to 10 to the -6th sq cm/proton. For individual devices, however, the soft error cross section consistently increased with beam energy from 18-130 MeV. Analysis indicates that the soft errors induced by energetic protons result from spallation interactions between the incident protons and the nuclei of the atoms comprising the device. Because energetic protons are the most numerous of both the galactic and solar cosmic rays and form the inner radiation belt, proton-induced soft errors have potentially serious implications for many electronic systems flown in space.
LYSO crystal testing for an EDM polarimeter
NASA Astrophysics Data System (ADS)
Müller, F.; Keshelashvili, I.; Mchedlishvili, D.;
2017-11-01
Four detector modules, built from three different LYSO crystals and two different types of light sensors (PMTs and SiPM arrays), have been tested with a deuteron beam from 100 MeV - 270 MeV at the COSY accelerator facility for the srEDM project at the Forschungszentrum Jülich in Germany. The detector modules were arranged in a cluster hand mounted on a positioning table. The deuteron beam was targeted at the center of each individual crystal for data analysis. The signals were digitized using a 14 bit, 250 MS/s flash ADC. Further, the energy spectra were calibrated using the known beam energies from the accelerator. From the calibrated spectra, the energy resolution was calculated. A resolution of 3% for the low energies and down to 1% for the high energy of 270 MeV was achieved. A deuteron reconstruction efficiency of almost 100% for low energies and around 70% for high energies was achieved. The SiPM light sensor showed a very good performance and will be used for the next generation of detector modules.
Compact NE213 neutron spectrometer with high energy resolution for fusion applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zimbal, A.; Reginatto, M.; Schuhmacher, H.
Neutron spectrometry is a tool for obtaining important information on the fuel ion composition, velocity distribution and temperature of fusion plasmas. A compact NE213 liquid scintillator, fully characterized at Physikalisch-Technische Bundesanstalt, was installed and operated at the Joint European Torus (JET) during two experimental campaigns (C8-2002 and trace tritium experiment-TTE 2003). The results show that this system can operate in a real fusion experiment as a neutron (1.5 MeV
Molecular Characterization of Wild Type Measles Virus from Adult Patients in Northern China, 2014.
Xu, Wen; Zhang, Ming-Xiang; Qin, En-Qiang; Yan, Ying-Chun; Li, Feng-Yi; Xu, Zhe; Tian, Xia; Fan, Rong; Tu, Bo; Chen, Wei-Wei; Zhao, Min
2016-04-01
In this study, we studied the N and H genes from wild type measles viruses (MeVs) isolated during the 2013-2014 outbreak. Clinical samples were collected, and the genotyping, phylogenetic analysis were performed. The vaccination rate of the study population was 4%. Genotype H1a was the predominant genotype. Wild type viruses were classified into clusters A and B, C and may have different origins. N-450 sequences from wild type viruses were highly homologous with, and likely evolved from MeVs circulating in Tianjing and Henan in 2012. MVs/Shenyang.CHN/18.14/3 could have evolved from MeVs from Liaoning, Beijing, Hebei, Heilongjiang, Henan, Jilin, and Tianjin. Our data suggested that one or more of the same viruses circulated between Beijing, Shenyang, Hong Kong, Taiwan and Berlin. Important factors contributing to outbreaks could include weak vaccination coverage, poor vaccination strategies, and migration of adult workers between cities, countries, and from rural areas to urban areas. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Precision Measurement of the p ( e , e ' p ) π 0 Reaction at Threshold
Chirapatpimol, K.; Shabestari, M. H.; Lindgren, R. A.; ...
2015-05-13
New results are reported from a measurement ofmore » $$\\pi^0$$ electroproduction near threshold using the p(e, e´p) π⁰ reaction. The experiment was designed to determine precisely the energy dependence of $s-$ and $p-$wave electromagnetic multipoles as a stringent test of the predictions of Chiral Perturbation Theory (ChPT). The data were taken with an electron beam energy of 1192 MeV using a two-spectrometer setup in Hall A at Jefferson Lab. For the first time, complete coverage of the $$\\phi^*_{\\pi}$$ and $$\\theta^*_{\\pi}$$ angles in the $$p \\pi^0$$ center-of-mass was obtained for invariant energies above threshold from 0.5 MeV up to 15 MeV. The 4-momentum transfer $Q^2$ coverage ranges from 0.05 to 0.155 (GeV/c)$^2$ in fine steps. A simple phenomenological analysis of our data shows strong disagreement with $p-$wave predictions from ChPT for $Q^2>0.07$ (GeV/c)$^2$, while the $s-$wave predictions are in reasonable agreement.« less
Finite volume effects in the chiral extrapolation of baryon masses
NASA Astrophysics Data System (ADS)
Lutz, M. F. M.; Bavontaweepanya, R.; Kobdaj, C.; Schwarz, K.
2014-09-01
We perform an analysis of the QCD lattice data on the baryon octet and decuplet masses based on the relativistic chiral Lagrangian. The baryon self-energies are computed in a finite volume at next-to-next-to-next-to-leading order (N3LO), where the dependence on the physical meson and baryon masses is kept. The number of free parameters is reduced significantly down to 12 by relying on large-Nc sum rules. Altogether we describe accurately more than 220 data points from six different lattice groups, BMW, PACS-CS, HSC, LHPC, QCDSF-UKQCD and NPLQCD. Values for all counterterms relevant at N3LO are predicted. In particular we extract a pion-nucleon sigma term of 39-1+2 MeV and a strangeness sigma term of the nucleon of σsN=84-4+28 MeV. The flavor SU(3) chiral limit of the baryon octet and decuplet masses is determined with (802±4) and (1103±6) MeV. Detailed predictions for the baryon masses as currently evaluated by the ETM lattice QCD group are made.
NASA Astrophysics Data System (ADS)
Zhu, T.; Ajo Franklin, J. B.; Daley, T. M.
2015-12-01
Continuous active source seismic measurements (CASSM) were collected in the crosswell geometry during scCO2 injection at the Frio-II brine pilot (Liberty, TX). Previous studies (Daley et.al. 2007, 2011) have demonstrated that spatial-temporal changes in the picked first arrival time after CO2 injection constrain the movement of the CO2 plume in the storage interval. To improve the quantitative constraints on plume saturation using this dataset, we investigate spatial-temporal changes in the seismic attenuation of the first arrivals. The attenuation changes over the injection period (~60 h) are estimated by the amount of the centroid frequency shift computed by the local time-frequency analysis. Our observations include: at receivers above the packer seismic attenuation does not change in a physical trend; at receivers below the packer attenuation sharply increases as the amount of CO2 plume increase at the first few hours and peaks at specific points varying with distributed receivers, which are consistent with observations from time delays of first arrivals. Then, attenuation decreases over the injection time with increased amount of CO2 plume. This bell-shaped attenuation response as a function of time in the experiment is consistent with White's patchy saturation model which predicts an attenuation peak at intermediate CO2 saturations. Our analysis suggests that spatial-temporal attenuation change is an indicator of the movement/saturation of CO2 plume at high saturations, a system state for which seismic measurements are typically only weakly sensitive to.
Quasifree analyzing powers using the (p-->,n) reaction
NASA Astrophysics Data System (ADS)
Hicks, K. H.; Vetterli, M. C.; Celler, A.; Helmer, R. L.; Henderson, R. S.; Jackson, K. P.; Jeppesen, R. G.; Trudel, A.; Yen, S.
1989-12-01
The (p-->,n) reaction has been measured for 12C and 54Fe targets at 290 MeV for a lab angle of 20.4° and at 420 MeV for a lab angle of 24.0°. An additional angle of 27.0° was measured for 12C at 290 MeV. Both cross sections and analyzing powers were obtained up to excitation energies close to the quasifree peak. The (p-->,n) analyzing powers are suppressed relative to the free nucleon-nucleon values for the 12C data at 290 and 420 MeV, and for the 54Fe data at 290 MeV. An enhanced analyzing power is observed for the 54Fe data at 420 MeV. The data are compared with both relativistic and nonrelativistic model calculations.
New measurement of the lifetime of the 2 + 1 state of 12Be
Morse, C.; McCutchan, E. A.; Iwasaki, H.; ...
2017-05-03
The lifetime of themore » $$2_1^+$$ state at 2.1 MeV in $$^{12}$$Be has been measured using inelastic scattering of a $$^{12}$$Be beam at 43 MeV/nucleon with a gold target. Through the Doppler shift attenuation method, the mean-life of the $$2_1^+$$ state has been determined as 2.5±0.7(stat)±0.3 (syst) ps, which gives a B(E2; $$2_1^+$$ → $$0_{g.s.}^+$$)) value of 4.9±1.3±0.5 in Weisskopf units. The result shows a large quadrupole strength in the ground state transition, providing further evidence on the disappearance of the N=8 magic number. The B(E2; $$2_1^+$$ → $$0_{g.s.}^+$$) value together with the deformation length measured by proton inelastic scattering yields a neutron quadrupole matrix element two times larger than those for $$^{14}$$C and $${16}$$O.« less
Effective atomic numbers and electron densities of bioactive glasses for photon interaction
NASA Astrophysics Data System (ADS)
Shantappa, Anil; Hanagodimath, S. M.
2015-08-01
This work was carried out to study the nature of mass attenuation coefficient of bioactive glasses for gamma rays. Bioactive glasses are a group of synthetic silica-based bioactive materials with unique bone bonding properties. In the present study, we have calculated the effective atomic number, electron density for photon interaction of some selected bioactive glasses viz., SiO2-Na2O, SiO2-Na2O-CaO and SiO2-Na2O-P2O5 in the energy range 1 keV to 100 MeV. We have also computed the single valued effective atomic number by using XMuDat program. It is observed that variation in effective atomic number (ZPI, eff) depends also upon the weight fractions of selected bioactive glasses and range of atomic numbers of the elements. The results shown here on effective atomic number, electron density will be more useful in the medical dosimetry for the calculation of absorbed dose and dose rate.
The Study of Rain Specific Attenuation for the Prediction of Satellite Propagation in Malaysia
NASA Astrophysics Data System (ADS)
Mandeep, J. S.; Ng, Y. Y.; Abdullah, H.; Abdullah, M.
2010-06-01
Specific attenuation is the fundamental quantity in the calculation of rain attenuation for terrestrial path and slant paths representing as rain attenuation per unit distance (dB/km). Specific attenuation is an important element in developing the predicted rain attenuation model. This paper deals with the empirical determination of the power law coefficients which allow calculating the specific attenuation in dB/km from the knowledge of the rain rate in mm/h. The main purpose of the paper is to obtain the coefficients of k and α of power law relationship between specific attenuation. Three years (from 1st January 2006 until 31st December 2008) rain gauge and beacon data taken from USM, Nibong Tebal have been used to do the empirical procedure analysis of rain specific attenuation. The data presented are semi-empirical in nature. A year-to-year variation of the coefficients has been indicated and the empirical measured data was compared with ITU-R provided regression coefficient. The result indicated that the USM empirical measured data was significantly vary from ITU-R predicted value. Hence, ITU-R recommendation for regression coefficients of rain specific attenuation is not suitable for predicting rain attenuation at Malaysia.
Sowers, Daniel; Liu, Yingzi; Mostafaei, Farshad; Blake, Scott; Nie, Linda H
2015-12-01
A neutron irradiation cavity for in vivo neutron activation analysis (IVNAA) to detect manganese, aluminum, and other potentially toxic elements in human hand bone has been designed and its dosimetric specifications measured. The neutron source is a customized deuterium-deuterium neutron generator that produces neutrons at 2.45 MeV by the fusion reaction 2H(d, n)3He at a calculated flux of 7 × 10(8) ± 30% s(-1). A moderator/reflector/shielding [5 cm high density polyethylene (HDPE), 5.3 cm graphite and 5.7 cm borated (HDPE)] assembly has been designed and built to maximize the thermal neutron flux inside the hand irradiation cavity and to reduce the extremity dose and effective dose to the human subject. Lead sheets are used to attenuate bremsstrahlung x rays and activation gammas. A Monte Carlo simulation (MCNP6) was used to model the system and calculate extremity dose. The extremity dose was measured with neutron and photon sensitive film badges and Fuji electronic pocket dosimeters (EPD). The neutron ambient dose outside the shielding was measured by Fuji NSN3, and the photon dose was measured by a Bicron MicroREM scintillator. Neutron extremity dose was calculated to be 32.3 mSv using MCNP6 simulations given a 10-min IVNAA measurement of manganese. Measurements by EPD and film badge indicate hand dose to be 31.7 ± 0.8 mSv for neutrons and 4.2 ± 0.2 mSv for photons for 10 min; whole body effective dose was calculated conservatively to be 0.052 mSv. Experimental values closely match values obtained from MCNP6 simulations. These are acceptable doses to apply the technology for a manganese toxicity study in a human population.
High energy neutrons at balloon altitudes
NASA Technical Reports Server (NTRS)
Klumpar, D. M.; Lockwood, J. A.
1974-01-01
The flux and energy spectrum of fast neutrons (3 to 20 MeV) has been measured near the top of the atmosphere with an organic liquid scintillator. The omnidirectional neutron energy spectrum from 3 to 20 MeV at 3.5 g/sq cm over Palestine, Texas can be described by a power law with an energy dependent spectral index which varies from 1.8 (plus or minus .2) between 1 and 10 MeV to 0.3 (plus or minus .3) between 15 and 20 MeV. From 20 to 50 MeV, a neutron spectrum independence of E is consistent with our data.
A Mobile Automated Tomographic Gamma Scanning System - 13231
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kirkpatrick, J.M.; LeBlanc, P.J.; Nakazawa, D.
2013-07-01
Canberra Industries have recently designed and built a new automated Tomographic Gamma Scanning (TGS) system for mobile deployment. The TGS technique combines high-resolution gamma spectroscopy with low spatial resolution 3-dimensional image reconstruction to provide increased accuracy over traditional approaches for the assay of non-uniform source distributions in low-to medium-density, non-heterogeneous matrices. Originally pioneered by R. Estep at Los Alamos National Laboratory (LANL), the TGS method has been further developed and commercialized by Canberra Industries in recent years. The present system advances the state of the art on several fronts: it is designed to be housed in a standard cargo transportmore » container for ease of transport, allowing waste characterization at multiple facilities under the purview of a single operator. Conveyor feed, drum rotator, and detector and collimator positioning mechanisms operated by programmable logic control (PLC) allow automated batch mode operation. The variable geometry settings can accommodate a wide range of waste packaging, including but not limited to standard 220 liter drums, 380 liter overpack drums, and smaller 20 liter cans. A 20 mCi Eu-152 transmission source provides attenuation corrections for drum matrices up to 1 g/cm{sup 3} in TGS mode; the system can be operated in Segmented Gamma Scanning (SGS) mode to measure higher density drums. To support TGS assays at higher densities, the source shield is sufficient to house an alternate Co-60 transmission source of higher activity, up to 250 mCi. An automated shutter and attenuator assembly is provided for operating the system with a dual intensity transmission source. The system's 1500 kg capacity rotator turntable can handle heavy containers such as concrete lined 380 liter overpack drums. Finally, data acquisition utilizes Canberra's Broad Energy Germanium (BEGE) detector and Lynx MCA, with 32 k channels, providing better than 0.1 keV/channel resolution to support both isotopic analysis with the MGA/MGAU software and a wide 3 MeV dynamic range. The calibration and verification of the system is discussed, and quantitative results are presented for a variety of drum types and matrices. (authors)« less
SU-E-T-470: Beam Performance of the Radiance 330 Proton Therapy System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nazaryan, H; Nazaryan, V; Wang, F
2014-06-01
Purpose: The ProTom Radiance 330 proton radiotherapy system is a fully functional, compact proton radiotherapy system that provides advanced proton delivery capabilities. It supports three-dimensional beam scanning with energy and intensity modulation. A series of measurements have been conducted to characterize the beam performance of the first installation of the system at the McLaren Proton Therapy Center in Flint, Michigan. These measurements were part of the technical commissioning of the system. Select measurements and results are presented. Methods: The Radiance 330 proton beam energy range is 70–250 MeV for treatment, and up to 330 MeV for proton tomography and radiography.more » Its 3-D scanning capability, together with a small beam emittance and momentum spread, provides a highly efficient beam delivery. During the technical commissioning, treatment plans were created to deliver uniform maps at various energies to perform Gamma Index analysis. EBT3 Gafchromic films were irradiated using the Planned irradiation maps. Bragg Peak chamber was used to test the dynamic range during a scan in one layer for high (250 MeV) and Low (70 MeV) energies. The maximum and minimum range, range adjustment and modulation, distal dose falloff (80%–20%), pencil beam spot size, spot placement accuracy were also measured. The accuracy testing included acquiring images, image registration, receiving correction vectors and applying the corrections to the robotic patient positioner. Results: Gamma Index analysis of the Treatment Planning System (TPS) data vs. Measured data showed more than 90% of points within (3%, 3mm) for the maps created by the TPS. At Isocenter Beam Size (One sigma) < 3mm at highest energy (250 MeV) in air. Beam delivery was within 0.6 mm of the intended target at the entrance and the exit of the beam, through the phantom. Conclusion: The Radiance 330 Beam Performance Measurements have confirmed that the system operates as designed with excellent clinical performance specifications. Hovakim Nazaryan, Vahagn Nazaryan and Fuhua Wang are employees of ProTom International, Inc. who contributed to the development and completed the technical commissioning of the Radiance 330 proton therapy delivery system manufactured by ProTom International.« less
Resonant Compton Upscattering Models of Magnetar Hard X-ray Emission and Polarization
NASA Astrophysics Data System (ADS)
Baring, Matthew G.; Wadiasingh, Zorawar; Gonthier, Peter L.; Kust Harding, Alice
2017-08-01
Non-thermal quiescent X-ray emission extending between 10 keV and around 150 keV has been seen in about 10 magnetars by RXTE, INTEGRAL, Suzaku and Fermi-GBM. For inner magnetospheric models of such hard X-ray signals, resonant Compton upscattering is anticipated to be the most efficient process for generating the continuum radiation. This is because the scattering becomes resonant at the cyclotron frequency, and the effective cross section exceeds the classical Thomson value by over two orders of magnitude. We present angle-dependent hard X-ray upscattering model spectra for uncooled monoenergetic relativistic electrons injected in inner regions of pulsar magnetospheres. These spectra are integrated over closed field lines and obtained for different observing perspectives. The spectral cut-off energies are critically dependent on the observer viewing angles and electron Lorentz factor. We find that electrons with energies less than around 15 MeV will emit most of their radiation below 250 keV, consistent with the observed turnovers in magnetar hard X-ray tails. Moreover, electrons of higher energy still emit most of the radiation below around 1 MeV, except for quasi-equatorial emission locales for select pulses phases. In such cases, attenuation mechanisms such as pair creation will be prolific, thereby making it difficult to observe signals extending into the Fermi-LAT band. Our spectral computations use new state-of-the-art, spin-dependent formalism for the QED Compton scattering cross section in strong magnetic fields. The emission exhibits strong polarization above around 30 keV that is anticipated to be dependent on pulse phase, thereby defining science agendas for future hard X-ray polarimeters.
High and low energy proton radiation damage in p/n InP MOCVD solar cells
NASA Technical Reports Server (NTRS)
Rybicki, George; Weinberg, Irving; Scheiman, Dave; Vargas-Aburto, Carlos
1995-01-01
InP p(+)nn(+) MOCVD solar cells were irradiated with 0.2 MeV and 10 MeV protons to a fluence of 10(exp 13)/sq cm. The degradation of power output, IV behavior, carrier concentration and defect concentration were observed at intermediate points throughout the irradiations. The 0.2 MeV proton irradiated solar cells suffered much greater and more rapid degradation in power output than those irradiated with 10 meV protons. The efficiency losses were accompanied by larger increases in the recombination currents in the 0.2 MeV proton irradiated solar cells. The low energy proton irradiations also had a larger impact on the series resistance of the solar cells. Despite the radiation induced damage, the carrier concentration in the base of the solar cells showed no reduction after 10 MeV or 0.2 MeV proton irradiations and even increased during irradiation with 0.2 MeV protons. In a DLTS study of the irradiated samples, the minority carrier defects H4 and H5 at E(v) + 0.33 and E(v) + 0.52 eV and the majority carrier defects E7 and E10 at E(c)- 0.39 and E(c)-0.74 eV, were observed. The defect introduction rates for the 0.2 MeV proton irradiations were about 20 times higher than for the 10 MeV proton irradiations. The defect E10, observed here after irradiation, has been shown to act as a donor in irradiated n-type InP and may be responsible for obscuring carrier removal. The results of this study are consistent with the much greater damage produced by low energy protons whose limited range causes them to stop in the active region of the solar cell.
NASA Astrophysics Data System (ADS)
Majstorović, Josipa; Belinić, Tena; Namjesnik, Dalija; Dasović, Iva; Herak, Davorka; Herak, Marijan
2017-09-01
The central part of the External Dinarides (CED) is a geologically and tectonically complex region formed in the collision between the Adriatic microplate and the European plate. In this study, the contributions of intrinsic and scattering attenuation (
NASA Astrophysics Data System (ADS)
Liu, Wen; Zhang, Yuying; Yang, Si; Han, Donghai
2018-05-01
A new technique to identify the floral resources of honeys is demanded. Terahertz time-domain attenuated total reflection spectroscopy combined with chemometrics methods was applied to discriminate different categorizes (Medlar honey, Vitex honey, and Acacia honey). Principal component analysis (PCA), cluster analysis (CA) and partial least squares-discriminant analysis (PLS-DA) have been used to find information of the botanical origins of honeys. Spectral range also was discussed to increase the precision of PLS-DA model. The accuracy of 88.46% for validation set was obtained, using PLS-DA model in 0.5-1.5 THz. This work indicated terahertz time-domain attenuated total reflection spectroscopy was an available approach to evaluate the quality of honey rapidly.
The Physics Analysis of a Gas Attenuator with Argon as a Working Gas (Rev. 1)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ryutov, D D; Bionta, R M; McKernan, M A
2006-01-03
A gas attenuator is an important element of the LCLS facility. The attenuator has to operate in a broad range of x-ray energies, provide attenuation coefficient between 1 and 10{sup 4} with the accuracy of 1% and, at the same time, be reliable and allow for many months of un-interrupted operation. A detailed design study of the attenuator based on the use of nitrogen as a working gas has been recently carried out by S. Shen [1]. In this note we assess the features of the attenuator based on the use of argon. We concentrate on the physics issues; themore » design features will probably be not that different from the aforementioned nitrogen attenuator. Although specific results obtained in our note pertain to argon, the general framework (and many equations obtained) are applicable also to the nitrogen attenuator. In the past, an analysis of the attenuator based on the use of a noble gas has already been carried out [2]. This analysis was performed for an extremely stringent set of specifications. In particular, a very large diameter for the unobstructed x-ray beam was set (1 cm) to accommodate the spontaneous radiation; the attenuator was supposed to cover the whole range of energies of the coherent radiation, from 800 eV to 8000 eV; the maximum attenuation was set at the level of 10{sup 4}; the use of solid attenuators was not allowed, as well as the use of rotating shutters. The need to reach a sufficient absorption at the high-energy end of the spectrum predetermined the choice of Xe as the working gas (in order to have a reasonable absorption at a not-too-high pressure). A sophisticated differential pumping system that included a Penning-type ion pump was suggested in order to minimize the gas leak into the undulator/accelerator part of the facility. A high cost of xenon meant also that an efficient (and expensive) gas-recovery system would have to be installed. The main parameter that determined the high cost and the complexity of the system was a large radius of the orifice. The present viewpoint allows for much smaller size of the orifice, a = 1.5 mm. The use of solid attenuators is also allowed for a higher-energy end of the spectrum. It is, therefore, worthwhile to reconsider various parameters of the gas attenuator for these much less stringent conditions. As a working gas we consider now the argon, which, on the one hand, provides reasonable absorption lengths and, on the other hand, is inexpensive enough to be exhausted into the atmosphere (no need for recovery). We concentrate on the processes in the main attenuation cell and just outside it, not touching upon a performance of the differential pumping system. The graphs presented in this report can serve for a general orientation only, not for getting exact numerical values of various parameters.« less
Precision Measurement of the Beryllium-7 Solar Neutrino Interaction Rate in Borexino
NASA Astrophysics Data System (ADS)
Saldanha, Richard Nigel
Solar neutrinos, since their first detection nearly forty years ago, have revealed valuable information regarding the source of energy production in the Sun, and have demonstrated that neutrino oscillations are well described by the Large Mixing Angle (LMA) oscillation parameters with matter interactions due to the Mikheyev-Smirnov-Wolfenstein (MSW) effect. This thesis presents a precision measurement of the 7Be solar neutrino interaction rate within Borexino, an underground liquid scintillator detector that is designed to measure solar neutrino interactions through neutrino-electron elastic scattering. The thesis includes a detailed description of the analysis techniques developed and used for this measurement as well as an evaluation of the relevant systematic uncertainties that affect the precision of the result. The rate of neutrino-electron elastic scattering from 0.862 MeV 7Be neutrinos is determined to be 45.4 +/- 1.6 (stat) +/- 1.5 (sys) counts/day/100 ton. Due to extensive detector calibrations and improved analysis methods, the systematic uncertainty in the interaction rate has been reduced by more than a factor of two from the previous evaluation. In the no-oscillation hypothesis, the interaction rate corresponds to a 0.862 MeV 7Be electron neutrino flux of (2.75 +/- 0.13) x 10 9 cm-2 sec-1. Including the predicted neutrino flux from the Standard Solar Model yields an electron neutrino survival probability of Pee 0.51 +/- 0.07 and rules out the no-oscillation hypothesis at 5.1sigma The LMA-MSW neutrino oscillation model predicts a transition in the solar Pee value between low (< 1 MeV) and high (> 10 MeV) energies which has not yet been experimentally confirmed. This result, in conjunction with the Standard Solar Model, represents the most precise measurement of the electron neutrino survival probability for solar neutrinos at sub-MeV energies.
Deuteron-induced reactions on Ni isotopes up to 60 MeV
NASA Astrophysics Data System (ADS)
Avrigeanu, M.; Šimečková, E.; Fischer, U.; Mrázek, J.; Novak, J.; Štefánik, M.; Costache, C.; Avrigeanu, V.
2016-07-01
Background: The high complexity of the deuteron-nucleus interaction from the deuteron weak binding energy of 2.224 MeV is also related to a variety of reactions induced by the deuteron-breakup (BU) nucleons. Thus, specific noncompound processes as BU and direct reactions (DR) make the deuteron-induced reactions so different from reactions with other incident particles. The scarce consideration of only pre-equilibrium emission (PE) and compound-nucleus (CN) mechanisms led to significant discrepancies with experimental results so that recommended reaction cross sections of high-priority elements as, e.g., Ni have mainly been obtained by fit of the data. Purpose: The unitary and consistent BU and DR account in deuteron-induced reactions on natural nickel may take advantage of an extended database for this element, including new accurate measurements of particular reaction cross sections. Method: The activation cross sections of 64,61,60Cu, Ni,5765, and 55,56,57,58,59m,60Co nuclei for deuterons incident on natural Ni at energies up to 20 MeV, were measured by the stacked-foil technique and high-resolution gamma spectrometry using U-120M cyclotron of CANAM, NPI CAS. Then, within an extended analysis of deuteron interactions with Ni isotopes up to 60 MeV, all processes from elastic scattering until the evaporation from fully equilibrated compound system have been taken into account while an increased attention is paid especially to the BU and DR mechanisms. Results: The deuteron activation cross-section analysis, completed by consideration of the PE and CN contributions corrected for decrease of the total-reaction cross section from the leakage of the initial deuteron flux towards BU and DR processes, is proved satisfactory for the first time to all available data. Conclusions: The overall agreement of the measured data and model calculations validates the description of nuclear mechanisms taken into account for deuteron-induced reactions on Ni, particularly the BU and DR that should be considered explicitly.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moskvin, V; Pirlepesov, F; Farr, J
2016-06-15
Purpose: Dose-weighted linear energy transfer (dLET) has been shown to be useful for the analysis of late effects in proton therapy. This study presents the results of the testing of the dLET concept for intensity modulated proton therapy (IMPT) with a discrete spot scanning beam system without use of an aperture or compensator (AC). Methods: IMPT (no AC) and broad beams (BB) with (AC) were simulated in the TOPAS and FLUKA code systems. Information from the independently tested Monte Carlo Damage Simulation (MCDS) was integrated into the FLUKA code systems to account for spatial variations in the RBE for protonsmore » and other light ions using an endpoint of DNA double strand break (DSB) induction. Results: The proton spectra for IMPT beams at the depths beyond the distal edge contain a tail of high energy protons up to 100 MeV. The integral from the tail is compatible with the number of 5–8 MeV protons at the tip of the Bragg peak (BP). The dose averaged energy (dEav) decreases to 7 MeV at the tip of (BP) and then increases to about 15 MeV beyond the distal edge. Neutrons produced in the nozzle are two orders of magnitude higher for BB with AC than for IMPT in low energy part of the spectra. The dLET values beyond of the distal edge of the BP are 5 times larger for the IMPT than for BB with the AC. Contrarily, negligible differences are seen in the RBE estimates for IMPT and BB with AC beyond the distal edge of the BP. Conclusion: The analysis of late effects in IMPT with a spot scanning and double scattering or scanning techniques with AC may requires both dLET and RBE as quantitative parameters to characterize effects beyond the distal edge of the BP.« less
Energy spectrum and flux of 3- to 20-Mev neutrons and 1- to 10-Mev gamma rays in the atmosphere
NASA Technical Reports Server (NTRS)
Klumpar, D. M.; Lockwood, J. A.; Saint Onge, R. N.; Friling, L. A.
1973-01-01
An experiment is described which was designed to measure the neutron and gamma ray energy spectrums and fluxes in the energy intervals 3 to 20 MeV and 1 to 10 MeV, respectively. In addition, from the 3 to 20-MeV proton recoil spectrums it is possible to infer the shape of the neutron energy spectrum from 20 to 50 MeV. The detecting system utilized a separate charged particle rejection scheme and a two-parameter display system for the output from the pulse shape discrimination which separated gamma rays from neutrons (n). Two long-duration flights were made with this detector in 1970 at Palestine, Tex. (P sub c = 4.6 Gv) and at Ft. Churchill, Canada (P sub c = 0.3 Gv).
Total cross section for the γd-->π-pp reaction between 380 and 840 MeV
NASA Astrophysics Data System (ADS)
Asai, M.; Endo, I.; Harada, M.; Kasai, S.; Niki, K.; Sumi, Y.; Kato, S.; Maruyama, K.; Murata, Y.; Muto, M.; Yoshida, K.; Iwatani, K.; Hasai, H.; Ito, H.; Maki, T.; Rangacharyulu, C.; Shimizu, H.; Wada, Y.
1990-09-01
The total cross section for the γd-->π-pp reaction has been measured for incident photon energies from 380 to 840 MeV in steps of 10 MeV, with the best energy resolution attained so far. A large-acceptance detector was used to observe the reaction products. Overall uncertainties in the deduced cross sections are less than 9% (~4% statistical and ~8% systematic). The results are in excellent agreement with previous bubble chamber measurements and do not show any statistically significant structure which can be interpreted as evidence for the formation of dibaryon resonances. An upper limit at 95% confidence level of σpeakΓ<230 μb MeV is obtained for a resonance in the vicinity of photon energy 700 MeV (mass~2490 MeV).
Z =50 core stability in 110Sn from magnetic-moment and lifetime measurements
NASA Astrophysics Data System (ADS)
Kumbartzki, G. J.; Benczer-Koller, N.; Speidel, K.-H.; Torres, D. A.; Allmond, J. M.; Fallon, P.; Abramovic, I.; Bernstein, L. A.; Bevins, J. E.; Crawford, H. L.; Guevara, Z. E.; Gürdal, G.; Hurst, A. M.; Kirsch, L.; Laplace, T. A.; Lo, A.; Matthews, E. F.; Mayers, I.; Phair, L. W.; Ramirez, F.; Robinson, S. J. Q.; Sharon, Y. Y.; Wiens, A.
2016-04-01
Background: The structure of the semimagic 50Sn isotopes were previously studied via measurements of B (E 2 ;21+→01+ ) and g factors of 21+ states. The values of the B (E 2 ;21+ ) in the isotopes below midshell at N = 66 show an enhancement in collectivity, contrary to predictions from shell-model calculations. Purpose: This work presents the first measurement of the 2 1+ and 4 1+ states' magnetic moments in the unstable neutron-deficient 110Sn. The g factors provide complementary structure information to the interpretation of the observed B (E 2 ) values. Methods: The 110Sn nuclei have been produced in inverse kinematics in an α -particle transfer reaction from 12C to 106Cd projectiles at 390, 400, and 410 MeV. The g factors have been measured with the transient field technique. Lifetimes have been determined from line shapes using the Doppler-shift attenuation method. Results: The g factors of the 21+ and 41+ states in 110Sn are g (21+) = +0.29(11) and g (41+) = +0.05(14), respectively. In addition, the g (41+) = +0.27(6) in 106Cd has been measured for the first time. A line-shape analysis yielded τ (110Sn ; 21+) = 0.81(10) ps and a lifetime of τ (110Sn ; 31-) = 0.25(5) ps was calculated from the fully Doppler-shifted γ line. Conclusions: No evidence has been found in 110Sn that would require excitation of protons from the closed Z =50 core.
Relationship between the start times of flares and CMEs to the time of potential radiation hazards
NASA Astrophysics Data System (ADS)
Kang, G.; Zheng, Y.; Kuznetsova, M. M.
2013-12-01
Solar flares, short-term outbursts of energy of the Sun, and coronal mass ejections (CME), massive bursts of solar matter, are two solar phenomena that are known to increase solar energetic particles in space. Increased solar energetic particles cause immense radiation that poses a serious threat to astronauts in space, radio communication signals, and passengers on high-latitude flights on the Earth. The relationship between the start times of flares and CMEs to the time of potential radiation hazards was investigated to determine how much warning time is available. Additionally, this project compared the difference between these relationships for four energy levels of solar energetic particles: proton flux exceeding 10 MeV, 30 MeV, 50 MeV and 100 MeV. This project gathered data of 22 recent SEP events between 2010 and 2012 and the parameters of associated CMEs and flares. Through the use of IDL (Interactive Data Language) programming, thorough analysis was conducted, including 2-sample t-tests and Kruskal-Wallis tests for 2 or more samples. The average lead time to warn humans of possible radiation hazard from the detection of a flare and a CME occurrence was found to be around 12 to 20 hours. The lead time was the greatest for the lowest energy level, though the differences in energy levels and that between the lead times for CME and flares were found to be statistically insignificant with p-values exceeding the alpha value of 0.20.
Monte Carlo Analysis of Pion Contribution to Absorbed Dose from Galactic Cosmic Rays
NASA Technical Reports Server (NTRS)
Aghara, S.K.; Battnig, S.R.; Norbury, J.W.; Singleterry, R.C.
2009-01-01
Accurate knowledge of the physics of interaction, particle production and transport is necessary to estimate the radiation damage to equipment used on spacecraft and the biological effects of space radiation. For long duration astronaut missions, both on the International Space Station and the planned manned missions to Moon and Mars, the shielding strategy must include a comprehensive knowledge of the secondary radiation environment. The distribution of absorbed dose and dose equivalent is a function of the type, energy and population of these secondary products. Galactic cosmic rays (GCR) comprised of protons and heavier nuclei have energies from a few MeV per nucleon to the ZeV region, with the spectra reaching flux maxima in the hundreds of MeV range. Therefore, the MeV - GeV region is most important for space radiation. Coincidentally, the pion production energy threshold is about 280 MeV. The question naturally arises as to how important these particles are with respect to space radiation problems. The space radiation transport code, HZETRN (High charge (Z) and Energy TRaNsport), currently used by NASA, performs neutron, proton and heavy ion transport explicitly, but it does not take into account the production and transport of mesons, photons and leptons. In this paper, we present results from the Monte Carlo code MCNPX (Monte Carlo N-Particle eXtended), showing the effect of leptons and mesons when they are produced and transported in a GCR environment.
Elastic neutron scattering studies at 96 MeV for transmutation.
Osterlund, M; Blomgren, J; Hayashi, M; Mermod, P; Nilsson, L; Pomp, S; Ohrn, A; Prokofiev, A V; Tippawan, U
2007-01-01
Elastic neutron scattering from (12)C, (14)N, (16)O, (28)Si, (40)Ca, (56)Fe, (89)Y and (208)Pb has been studied at 96 MeV in the10-70 degrees interval, using the SCANDAL (SCAttered Nucleon Detection AssembLy) facility. The results for (12)C and (208)Pb have recently been published, while the data on the other nuclei are under analysis. The achieved energy resolution, 3.7 MeV, is about an order of magnitude better than for any previous experiment above 65 MeV incident energy. A novel method for normalisation of the absolute scale of the cross section has been used. The estimated normalisation uncertainty, 3%, is unprecedented for a neutron-induced differential cross section measurement on a nuclear target. Elastic neutron scattering is of utmost importance for a vast number of applications. Besides its fundamental importance as a laboratory for tests of isospin dependence in the nucleon-nucleon, and nucleon-nucleus, interaction, knowledge of the optical potentials derived from elastic scattering come into play in virtually every application where a detailed understanding of nuclear processes is important. Applications for these measurements are dose effects due to fast neutrons, including fast neutron therapy, as well as nuclear waste incineration and single event upsets in electronics. The results at light nuclei of medical relevance ((12)C, (14)N and (16)O) are presented separately. In the present contribution, results on the heavier nuclei are presented, among which several are of relevance to shielding of fast neutrons.
NASA Astrophysics Data System (ADS)
Bali, Gunnar S.; Collins, Sara; Cox, Antonio; Schäfer, Andreas; RQCD Collaboration
2017-10-01
We perform a high statistics study of the JP=0+ and 1+ charmed-strange mesons, Ds0 *(2317 ) and Ds 1(2460 ), respectively. The effects of the nearby D K and D*K thresholds are taken into account by employing the corresponding four-quark operators. Six ensembles with Nf=2 nonperturbatively O (a ) improved clover Wilson sea quarks at a =0.07 fm are employed, covering different spatial volumes and pion masses: linear lattice extents L /a =24 , 32, 40, 64, equivalent to 1.7 fm to 4.5 fm, are realized for mπ=290 MeV and L /a =48 , 64 or 3.4 fm and 4.5 fm for an almost physical pion mass of 150 MeV. Through a phase shift analysis and the effective range approximation we determine the scattering lengths, couplings to the thresholds and the infinite-volume masses. Differences relative to the experimental values are observed for these masses, however, this is likely to be due to discretization effects as spin-averaged quantities and splittings are reasonably compatible with experiment. We also compute the weak decay constants of the scalar and axialvector and find fV0+=114 (2 )(0 )(+5 )(10 ) MeV and fA1+=194 (3 )(4 )(+5 )(10 ) MeV , where the errors are due to statistics, renormalization, finite-volume and lattice spacing effects.
Injection of electrons and protons with energies of tens of MeV into L less than 3 on 24 March 1991
NASA Technical Reports Server (NTRS)
Blake, J. B.; Kolasinski, W. A.; Fillius, R. W.; Mullen, E. G.
1992-01-01
On 24 March 1991 instrumentation aboard CRRES observed the almost instantaneous injection of electrons and protons with energies above 15 MeV into the L-region in the range 2-3. The energy spectrum of the injected electrons, a power law (E exp -6) peaked at 15 MeV and continued to at least 50 MeV.
El-Merhi, Fadi; Mohamad, May; Haydar, Ali; Naffaa, Lena; Nasr, Rami; Deeb, Ibrahim Al-Sheikh; Hamieh, Nadine; Tayara, Ziad; Saade, Charbel
2018-04-01
To evaluate the performance of non-contrast computed tomography (CT) by reporting the difference in attenuation between normal and inflamed renal parenchyma in patients clinically diagnosed with acute pyelonephritis (APN). This is a retrospective study concerned with non-contrast CT evaluation of 74 patients, admitted with a clinical diagnosis of APN and failed to respond to 48h antibiotics treatment. Mean attenuation values in Hounsfield units (HU) were measured in the upper, middle and lower segments of the inflamed and the normal kidney of the same patient. Independent t-test was performed for statistical analysis. Image evaluation included receiver operating characteristic (ROC), visual grading characteristic (VGC) and kappa analyses. The mean attenuation in the upper, middle and lower segments of the inflamed renal cortex was 32%, 25%, and 29% lower than the mean attenuation of the corresponding cortical segments of the contralateral normal kidney, respectively (p<0.01). The mean attenuation in the upper, middle, and lower segments of the inflamed renal medulla was 48%, 21%, and 30%, lower than the mean attenuation of the corresponding medullary segments of the contralateral normal kidney (p<0.02). The mean attenuation between the inflamed and non-inflamed renal cortex and medulla was 29% and 30% lower respectively (p<0.001). The AUCROC (p<0.001) analysis demonstrated significantly higher scores for pathology detection, irrespective of image quality, compared to clinical and laboratory results with an increased inter-reader agreement from poor to substantial. Non-contrast CT showed a significant decrease in the parenchymal density of the kidney affected with APN in comparison to the contralateral normal kidney of the same patient. This can be incorporated in the diagnostic criteria of APN in NCCT in the emergency setting. Copyright © 2017 Elsevier Inc. All rights reserved.
Neutron scattering measurements in {sup 197}Au from 850 keV to 2.0 MeV
DOE Office of Scientific and Technical Information (OSTI.GOV)
O`Connor, M.; Chen, J.; Egan, J.J.
1995-10-01
Differential elastic and inelastic neutron scattering cross-sections for low lying levels in {sup 197}Au have been measured for incident neutron energies of 1.0 MeV, 1.5 MeV and 2.0 MeV. In addition, the total neutron cross sections in {sup 197}Au was measured from 850 keV to 1.5 MeV. For both experiments the UML 5.5 MV Van-de-Graaff accelerator with a Mobley post acceleration compression system, produced subnanosecond proton pulses which generated neutrons via the {sup 7}Li(p,n) {sup 7}Be reaction.
Anomaly in the quiet-time helium spectrum at 1 MeV per nucleon
NASA Technical Reports Server (NTRS)
Gloeckler, G.; Hovestadt, D.; Klecker, B.; Vollmer, O.; Fan, C. Y.
1975-01-01
An unusual spectral feature and anomalously large abundance of helium between 0.6 and approximately 2 MeV per nucleon observed during the most quiet time periods in 1974 and 1975 indicate the presence of low energy helium of an unknown origin. Alphas below 0.6 MeV per nucleon and protons below 1.5 MeV have an E to the minus 1.8 power spectrum and the proton to alpha ratio is about 30. These less than or equal 1 MeV particles are found to be emitted continuously by the sun even during its most inactive periods.
Giant quadrupole and monopole resonances in /sup 28/Si
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lui, Y.; Bronson, J.D.; Youngblood, D.H.
1985-05-01
Inelastic alpha scattering measurements have been performed for /sup 28/Si at small angles including zero degrees. A total of 66% of the E0 energy-weighted sum rule was identified (using a Satchler version 2 form factor) centered at E/sub x/ = 17.9 MeV having a width of 4.8 MeV and 34% of the E2 energy-weighted sum rule was identified above E/sub x/ = 15.3 MeV centered at 19.0 MeV with a width of 4.4 MeV. The dependence of the extracted E0 strength on form factor and optical potential was explored.
Strange baryons with two heavy quarks
NASA Astrophysics Data System (ADS)
Karliner, Marek; Rosner, Jonathan L.
2018-05-01
The LHCb Experiment at CERN has observed a doubly-charmed baryon Ξcc ++=c c u with a mass of 3621.40 ±0.78 MeV , consistent with many predictions. We use the same methods that led us to predict M (Ξc c,JP=1 /2+)=3627 ±12 MeV and M (Ξcc *,JP=3 /2+)=3690 ±12 MeV to predict M (Ωcc +,JP=1 /2+)=3692 ±16 MeV and M (Ωcc *,JP=3 /2+)=3756 ±16 MeV . Production and decay are discussed briefly, and predictions for M (Ωb c) and M (Ωb b) are included.
Variable optical attenuator and dynamic mode group equalizer for few mode fibers.
Blau, Miri; Weiss, Israel; Gerufi, Jonathan; Sinefeld, David; Bin-Nun, Moran; Lingle, Robert; Grüner-Nielsen, Lars; Marom, Dan M
2014-12-15
Variable optical attenuation (VOA) for three-mode fiber is experimentally presented, utilizing an amplitude spatial light modulator (SLM), achieving up to -28dB uniform attenuation for all modes. Using the ability to spatially vary the attenuation distribution with the SLM, we also achieve up to 10dB differential attenuation between the fiber's two supported mode group (LP₀₁ and LP₁₁). The spatially selective attenuation serves as the basis of a dynamic mode-group equalizer (DME), potentially gain-balancing mode dependent optical amplification. We extend the experimental three mode DME functionality with a performance analysis of a fiber supporting 6 spatial modes in four mode groups. The spatial modes' distribution and overlap limit the available dynamic range and performance of the DME in the higher mode count case.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jabran Zahid, H.; Kudritzki, Rolf-Peter; Ho, I-Ting
We analyze the optical continuum of star-forming galaxies in the Sloan Digital Sky Survey by fitting stacked spectra with stellar population synthesis models to investigate the relation between stellar mass, stellar metallicity, dust attenuation, and star formation rate. We fit models calculated with star formation and chemical evolution histories that are derived empirically from multi-epoch observations of the stellar mass–star formation rate and the stellar mass–gas-phase metallicity relations, respectively. We also fit linear combinations of single-burst models with a range of metallicities and ages. Star formation and chemical evolution histories are unconstrained for these models. The stellar mass–stellar metallicity relationsmore » obtained from the two methods agree with the relation measured from individual supergiant stars in nearby galaxies. These relations are also consistent with the relation obtained from emission-line analysis of gas-phase metallicity after accounting for systematic offsets in the gas-phase metallicity. We measure dust attenuation of the stellar continuum and show that its dependence on stellar mass and star formation rate is consistent with previously reported results derived from nebular emission lines. However, stellar continuum attenuation is smaller than nebular emission line attenuation. The continuum-to-nebular attenuation ratio depends on stellar mass and is smaller in more massive galaxies. Our consistent analysis of stellar continuum and nebular emission lines paves the way for a comprehensive investigation of stellar metallicities of star-forming and quiescent galaxies.« less
NASA Astrophysics Data System (ADS)
Nandasiri, M. I.; Moore, A.; Garratt, E.; Wickey, K. J.; AlFaify, S.; Gao, X.; Kayani, A.; Ingram, D.
2009-03-01
Unbalanced magnetron sputtering deposition of C-H films has been performed with various levels of negative substrate bias and with a fixed flow rate of hydrogen. Argon was used as a sputtering gas and formed the majority of the gas in the plasma. The effect of hydrogenation on the final concentration of trapped elements and their thermal stability with respect to hydrogen content is studied using ion beam analysis (IBA) techniques. The elemental concentrations of the films were measured in the films deposited on silicon substrates with a 2.5 MeV of H+ beam, which is used to perform Rutherford Backscattering Spectrometry (RBS) and Non-Rutherford Backscattering spectrometry (NRBS) and with 16 MeV of O5+ beam, used to perform Elastic Recoil Detection Analysis (ERDA). Effect of bias on the thermal stability of trapped hydrogen in the films has been studied. As the films were heated in-situ in vacuum using a non-gassy button heater, hydrogen was found to be decreasing around 400° C.
Measurements of galactic plane gamma ray emission in the energy range from 10 - 80 MeV
NASA Technical Reports Server (NTRS)
Bertsch, D. L.; Kniffen, D. A.
1982-01-01
A spark chamber gamma ray telescope was developed and flown to observe diffuse gamma ray emission from the central region of the galaxy. The extension of observations down to 10 MeV provides important new data indicating that the galactic diffuse gamma ray spectrum continues as a power law down to about 10 MeV, an observation in good agreement with recent theoretical predictions. Data from other experiments in the range from 100 keV to 10 MeV show a significant departure from the extension of the power-law fit to the medium energy observations reported here, possibly indicating that a different mechanism may be responsible for the emissions below and above a few MeV. The intensity of the spectrum above 10 MeV implies a galactic electron spectrum which is also very intense down to about 10 MeV. Electrons in this energy range cannot be observed in the solar cavity because of solar modulation effects. The galactic gamma ray data are compared with recent theoretical predictions.
Search for a massive short-lived axion in nuclear transitions
NASA Astrophysics Data System (ADS)
Hatzikoutelis, Athanasios
Recent reports of the possible existence of an Axion with mass = 9.5 MeV and lifetime less than 10-14 sec do not contradict any negative results of the 20-year long search. The present work aims at confirming or disproving these reports. An Axion may compete with M1 nuclear transitions and decay into a e+-e- pair, producing events with high angle separation, thus being detectable in the presence of internal pair conversion which favors small separation angles. In the present experiment the M1 transitions from two discrete states in 12C were produced using a (d,n) reaction. A hermetic array of plastic scintillator detectors for e+-e- pairs from nuclear transitions was upgraded to 65 elements covering 50% of 4pi. A target chamber made of carbon fiber/epoxy resin, with wall thickness 0.8 mm, was introduced which absorbs only 172. 2 keV of the kinetic energy of minimum ionizing e+/e-. A neutron detector with total efficiency of 3% was constructed to measure the time of flight of neutrons. The detectors and chamber were installed on the beam line of the Stony Brook heavy ion LINAC. A test run was conducted using the reaction 11B(p,e+e-)12C (Ep = 7.2 MeV) to populate the Giant Dipole Resonance of 12C. The observation of the IPC from the 22.6-MeV E1 transition to the ground state of 12C established the pair-energy line-shape and produced an absolute pairenergy calibration. The angular correlation distribution of the pairs was found to be in agreement with the Born and point nucleus approximation of E1 angular correlations. A data run with the stripping reaction 11B(d,n)12C* (Ed = 7.2 MeV) populated the (Ipi,T) = (1+,1) 15.11-MeV and the (1 +,0) 12.7-MeV states of 12C. Detected pair events without neutron coincidence required showed a clear and strong peak of the 15.11 MeV to ground state transition. Analysis of these data agreed with angular correlations of M1 internal pair conversion. These did not support the earlier work and showed no evidence of an Axion emitted in the transition. A second test with neutron coincidence required, demonstrated that the full experiment is working as designed. However, for the kinematically complete experiment including neutron coincidence the rate of good events was found to be only 4--6 events/hr. A statistically decisive test will take data runs of about six months.
NASA Technical Reports Server (NTRS)
1991-01-01
Topics addressed are: (1) an artificial gravity assessment study; (2) Mars mission transport vehicle (MTV)/Mars excursion vehicle (MEV) mission scenarios; (3) aerobrake issues; (4) equipment life and self-check; (5) earth-to-orbit (ETO) heavy lift launch vehicle (HLLV) definition trades; and (6) risk analysis.
Boatwright, John
2018-06-21
We analyze the Fourier spectra of S+Lg+surface wave groups from the horizontal and vertical components of broadband and accelerogram recordings of 120 small and moderate (2< Mw <6) earthquakes recorded by Canadian and American stations sited on rock at distances from 3 to 600 kilometers. There are seven Mw 4.0–4.5, six Mw 4.5–5.0, and three Mw ≥5 earthquakes in this event set. We test the regional spectral analysis by comparing the moment magnitudes with the moment magnitudes from the earthquake moment tensors determined by Bob Herrmann (St. Louis University) for 27 events, obtaining dMw=0.004±0.074. We determine the Lg attenuation in seven regions within northeastern North America: Charlevoix, lower St. Lawrence, Maine, Northern New York, lower Great Lakes, Ontario, and Nunavut. These attenuation estimates yield an average attenuation Q= (368±13)f (0.54±0.02) for the Appalachian region, a stronger attenuation Q= (317±16)f (0.54±0.03) for the Appalachian lowlands, and a weaker attenuation Q=(455±20)f (0.51±0.02) for Ontario and western Quebec. For events in Nunavut and northernmost Quebec, we estimate a similar attenuation for r <450 km, but a weaker attenuation Q= (773±70)f (0.27±0.06) for Lg propagation for 450< r <1700 kilometers. This far-regional attenuation allows us to analyze recordings of the 1989 Ungava and Payne Bay earthquakes obtained in Ontario and southern Quebec. We use these regional attenuations to determine the corner frequencies, stress drops, and radiated energies of the 120 earthquakes.
Measurements of the 169Tm(n,2n)168Tm cross section between 9.0 and 17.5 MeV
NASA Astrophysics Data System (ADS)
Soter, J.; Bhike, Megha; Krishichayan, Fnu; Finch, S. W.; Tornow, W.
2016-09-01
Measurements of the 169Tm(n,2n)168Tm cross section have been performed in 0.5 MeV intervals for neutron energies ranging from 9.0 MeV to 17.5 MeV in order to resolve discrepancies in the current literature data. The neutron activation technique was used with 90Zr and 197Au as monitor foils. After irradiation, de-excitation gamma rays were recorded off-line with High-Purity Germanium (HPGE) detectors in TUNL's Low-Background Counting Facility. In addition, data for the 169Tm(n,3n)167Tm reaction have also been obtained from 15.5 MeV to 17.5 MeV. The results of these measurements provide the basis for investigating properties of the interial confinement fusion plasma in deuterium-tritium (DT) capsules at the National Ignition Facility located at Lawrence Livermore National Laboratory.
NASA Astrophysics Data System (ADS)
Alford, W. P.; Helmer, R. L.; Abegg, R.; Celler, A.; Frekers, D.; Green, P.; Häusser, O.; Henderson, R.; Hicks, K.; Jackson, K. P.; Jeppesen, R.; Miller, C. A.; Trudel, A.; Vetterli, M.; Yen, S.; Pourang, R.; Watson, J.; Brown, B. A.; Engel, J.
1990-07-01
Cross sections for the 48Ti(n, p) reaction have been measured at angles of 0°, 6°, and 12° at an energy of 200 MeV. The measurements are compared with results of DWIA calculations to obtain estimates of transition strengths for L = 0, 1, and ⩾2 up to an excitation energy of 25 MeV. Gamow-Teller strength ( L = 0) is peaked between 3 and 4 MeV excitation energy, with a significant distribution extending to about 12 MeV. The L = 1 strength is found mainly between 6 and 20 MeV while the cross section for transitions with L ⩾2 increases from 10 MeV to the upper limit of the measurements. The distribution of Gamow-Teller strength is in poor agreement with theoretical distributions used to calculate the lifetime for double beta decay of 48Ca.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Iwamoto, Yosuke; /JAERI, Kyoto; Taniguchi, Shingo
Neutron energy spectra at 0{sup o} produced from stopping-length graphite, aluminum, iron and lead targets bombarded with 140, 250 and 350 MeV protons were measured at the neutron TOF course in RCNP of Osaka University. The neutron energy spectra were obtained by using the time-of-flight technique in the energy range from 10 MeV to incident proton energy. To compare the experimental results, Monte Carlo calculations with the PHITS and MCNPX codes were performed using the JENDL-HE and the LA150 evaluated nuclear data files, the ISOBAR model implemented in PHITS, and the LAHET code in MCNPX. It was found that thesemore » calculated results at 0{sup o} generally agreed with the experimental results in the energy range above 20 MeV except for graphite at 250 and 350 MeV.« less
Previous design restraints and radiation damage effects of low energy particles
NASA Technical Reports Server (NTRS)
Trainor, J. H.
1972-01-01
Spacecraft design fluences and damage by low energy electrons and protons are summarized. For electron energies 5 MeV, the design fluence is 10 to the 11th power electrons/sq cm; for energies 5 MeV, the integral spectrum is assumed to go as 1/E sq. The design fluences for proton energies 30 MeV is 1.5 x 10 to the 9th power protons/sq cm; for energies 100 MeV, it is 5 x 10 to the 14th power protons/sq cm. The radioisotope thermoelectric generator gamma and neutron radiation constraints are listed. Damage due to electron energies 0.5 MeV and proton energies 10 MeV are summarized for effects on spacecraft thermal surfaces, reflective surfaces, and refractive materials. The high frequency noise figure for field effect transistors may increase markedly, and another effect is the buildup of charge on insulating surfaces, resulting in large electric fields.
Abdelhamid, Mahmoud; Mosharafa, Ashraf A; Ibrahim, Hamdy; Selim, Hany M; Hamed, Mohamed; Elghoneimy, Mohamed N; Salem, Hosny K; Abdelazim, Mohamed S; Badawy, Hesham
2016-11-01
To evaluate the ability of noncontrast CT parameters (stone size, stone attenuation, and skin-to-stone distance [SSD]) to predict the outcome of extracorporeal shockwave lithotripsy (SWL) in a prospective cohort of patients with renal and upper ureteric stones. Patients with stones 5 to 20 mm were prospectively enrolled from 2011 to 2014. Patients had NCCT with recording of stone size, stone mean attenuation, and SSD, as well as various stone and patient parameters. The numbers of needed sessions as well as the final outcome were determined, with SWL failure defined as residual fragments >3 mm. Predictors of SWL failure were assessed by multiple regression analysis. Two hundred twenty patients (mean ± standard deviation [SD] age 41.5 ± 12.4 years) underwent SWL. Mean ± SD stone size was 11.3 ± 4.1 mm, while mean ± SD stone attenuation was 795.1 ± 340.4 HU. Mean ± SD SSD was 9.4 ± 2.1 cm. The average number of sessions was 1.64. SWL was effective in 186 (84.5%) patients (group A), while 34 (15.5%) patients had significant residual fragments (>3 mm). On univariate analysis, predictors of SWL failure included stone attenuation >1000 HU, older age, higher body mass index, higher attenuation value, larger stone size, and longer SSD. Increased SSD and higher stone attenuation retained their significance as independent predictors of SWL failure (p < 0.05) on multiple regression analysis both after first session and as final SWL outcome. A positive correlation was found between number of SWL sessions and mean stone attenuation (r = 0.6, p < 0.001) and SSD (r = 4, p < 0.001). Stone mean attenuation and SSD on noncontrast CT are significant independent predictors of SWL outcome in patients with renal and ureteric stones. These parameters should be included in clinical decision algorithms for patients with urolithiasis. For patients with stones having mean attenuation of >1000 HU and/or large SSDs, alternatives to SWL should be considered.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Belley, Matthew D.; Segars, William Paul; Kapadia, Anuj J., E-mail: anuj.kapadia@duke.edu
2014-06-15
Purpose: Understanding the radiation dose to a patient is essential when considering the use of an ionizing diagnostic imaging test for clinical diagnosis and screening. Using Monte Carlo simulations, the authors estimated the three-dimensional organ-dose distribution from neutron and gamma irradiation of the male liver, female liver, and female breasts for neutron- and gamma-stimulated spectroscopic imaging. Methods: Monte Carlo simulations were developed using the Geant4 GATE application and a voxelized XCAT human phantom. A male and a female whole body XCAT phantom was voxelized into 256 × 256 × 600 voxels (3.125 × 3.125 × 3.125 mm{sup 3}). A monoenergeticmore » rectangular beam of 5.0 MeV neutrons or 7.0 MeV photons was made incident on a 2 cm thick slice of the phantom. The beam was rotated at eight different angles around the phantom ranging from 0° to 180°. Absorbed dose was calculated for each individual organ in the body and dose volume histograms were computed to analyze the absolute and relative doses in each organ. Results: The neutron irradiations of the liver showed the highest organ dose absorption in the liver, with appreciably lower doses in other proximal organs. The dose distribution within the irradiated slice exhibited substantial attenuation with increasing depth along the beam path, attenuating to ∼15% of the maximum value at the beam exit side. The gamma irradiation of the liver imparted the highest organ dose to the stomach wall. The dose distribution from the gammas showed a region of dose buildup at the beam entrance, followed by a relatively uniform dose distribution to all of the deep tissue structures, attenuating to ∼75% of the maximum value at the beam exit side. For the breast scans, both the neutron and gamma irradiation registered maximum organ doses in the breasts, with all other organs receiving less than 1% of the breast dose. Effective doses ranged from 0.22 to 0.37 mSv for the neutron scans and 41 to 66 mSv for the gamma scans. Conclusions: Neutron and gamma irradiation of a primary target organ was found to impart the majority of the total dose to the primary target organ (and other large organs) within the beam plane and considerably lower dose to proximal organs outside of the beam. These results also indicate that despite the use of a highly scattering particle such as a neutron, the dose from neutron stimulated emission computed tomography scans is on par with other clinical imaging techniques such as x-ray computed tomography (x-ray CT). Given the high nonuniformity in the dose across an organ during the neutron scan, care must be taken when computing average doses from neutron irradiations. The effective doses from neutron scanning were found to be comparable to x-ray CT. Further technique modifications are needed to reduce the effective dose levels from the gamma scans.« less
Monte Carlo simulation of MOSFET dosimeter for electron backscatter using the GEANT4 code.
Chow, James C L; Leung, Michael K K
2008-06-01
The aim of this study is to investigate the influence of the body of the metal-oxide-semiconductor field effect transistor (MOSFET) dosimeter in measuring the electron backscatter from lead. The electron backscatter factor (EBF), which is defined as the ratio of dose at the tissue-lead interface to the dose at the same point without the presence of backscatter, was calculated by the Monte Carlo simulation using the GEANT4 code. Electron beams with energies of 4, 6, 9, and 12 MeV were used in the simulation. It was found that in the presence of the MOSFET body, the EBFs were underestimated by about 2%-0.9% for electron beam energies of 4-12 MeV, respectively. The trend of the decrease of EBF with an increase of electron energy can be explained by the small MOSFET dosimeter, mainly made of epoxy and silicon, not only attenuated the electron fluence of the electron beam from upstream, but also the electron backscatter generated by the lead underneath the dosimeter. However, this variation of the EBF underestimation is within the same order of the statistical uncertainties as the Monte Carlo simulations, which ranged from 1.3% to 0.8% for the electron energies of 4-12 MeV, due to the small dosimetric volume. Such small EBF deviation is therefore insignificant when the uncertainty of the Monte Carlo simulation is taken into account. Corresponding measurements were carried out and uncertainties compared to Monte Carlo results were within +/- 2%. Spectra of energy deposited by the backscattered electrons in dosimetric volumes with and without the lead and MOSFET were determined by Monte Carlo simulations. It was found that in both cases, when the MOSFET body is either present or absent in the simulation, deviations of electron energy spectra with and without the lead decrease with an increase of the electron beam energy. Moreover, the softer spectrum of the backscattered electron when lead is present can result in a reduction of the MOSFET response due to stronger recombination in the SiO2 gate. It is concluded that the MOSFET dosimeter performed well for measuring the electron backscatter from lead using electron beams. The uncertainty of EBF determined by comparing the results of Monte Carlo simulations and measurements is well within the accuracy of the MOSFET dosimeter (< +/- 4.2%) provided by the manufacturer.
Skeletal dosimetry in a voxel-based rat phantom for internal exposures to photons and electrons
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xie Tianwu; Han Dao; Liu Yang
2010-05-15
Purpose: The skeleton makes a significant contribution to the whole body absorbed dose evaluation of rats, since the bone marrow and bone surface in the skeleton express high radiosensitivity and are considered to be important dose-limiting tissues. The bone marrow can be categorized as red bone marrow (RBM) and yellow bone marrow (YBM). It is important to investigate the bone marrow in skeletal dosimetry. Methods: Cryosectional color images of the skeleton of a 156 g rat were segmented into mineral bone (including cortical bone and trabecular bone), RBM, and YBM. These three tissue types were identified at 40 different bonemore » sites and integrated into a previously developed voxel-based rat computational phantom. Photon and electron skeletal absorbed fractions were then calculated using the MCNPX Monte Carlo code. Results: Absorbed fraction (AF) and specific absorbed fraction (SAF) for mineral bone, RBM, and YBM at the 40 different bone sites were established for monoenergetic photon and electron sources placed in 18 organs and seven bone sites. Discrete photon energy was varied from 0.01 to 5.0 MeV in 21 discrete steps, while 21 discrete electron energies were studied, from 0.1 to 10.0 MeV. The trends and values found were consistent with the results of other researchers [M. G. Stabin, T. E. Peterson, G. E. Holburn, and M. A. Emmons, ''Voxel-based mouse and rat models for internal dose calculations,'' J. Nucl. Med. 47, 655-659 (2006)]. S-factors for the radionuclides {sup 169}Er, {sup 143}Pr, {sup 89}Sr, {sup 32}P, and {sup 90}Y, located in 18 organs and seven bone sites for the skeleton, were calculated and are provided in detail. Conclusions: For internal dose calculations, the AF data reveal that the mineral bone in the rat skeletal system is responsible for significant attenuation of gamma rays, especially at low energies. The photon SAF curves of RBM show that, for photon energies greater than 0.6 MeV, there is an increase in secondary photons emitted from the mineral bone as photon energy increases. The SAF values calculated in this study can also be used to determine the absorbed dose to the skeletal system of rats. The S-factors generated here will be useful in preclinical targeted radiotherapy experiments.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Watanabe, Y., E-mail: watanabe@aees.kyushu-u.ac.jp; Abe, S.
Terrestrial neutron-induced soft errors in MOSFETs from a 65 nm down to a 25 nm design rule are analyzed by means of multi-scale Monte Carlo simulation using the PHITS-HyENEXSS code system. Nuclear reaction models implemented in PHITS code are validated by comparisons with experimental data. From the analysis of calculated soft error rates, it is clarified that secondary He and H ions provide a major impact on soft errors with decreasing critical charge. It is also found that the high energy component from 10 MeV up to several hundreds of MeV in secondary cosmic-ray neutrons has the most significant sourcemore » of soft errors regardless of design rule.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ibraheem, Awad A., E-mail: awad-ah-eb@hotmail.com
Elastic scattering of {sup 4}He+{sup 40}Ca and {sup 4}He+{sup 44}Ti reactions at backward angles has been analyzed using two different models, microscopic and semimicroscopic folding potentials. The derived real potentials supplemented with phenomenological Woods–Saxon imaginary potentials, provide good agreement with the experimental data at energy E{sub c.m.} = 21.8 MeV without need to renormalize the potentials. Coupled channels calculations are used to extract the inelastic scattering cross section to the low-lying state 2+ (1.083 MeV) of {sup 44}Ti. The deformation length is obtained and compared with the electromagnetic measurement values as well as those obtained from previous studies.
The Voyager Cosmic Ray Experiment
NASA Technical Reports Server (NTRS)
Stilwell, D. E.; Davis, W. D.; Joyce, R. M.; Mcdonald, F. B.; Trainor, J. H.; Althouse, W. E.; Cummings, A. C.; Garrard, T. L.; Stone, E. C.; Vogt, R. E.
1979-01-01
The Voyager Cosmic Ray Experiment includes seven dE/dx-E telescopes to measure the energy and charge of particles with atomic numbers from 1 to 26 in the energy range 1-500 MeV/nucleon and to measure electron energy in the range from 3 to 110 MeV. Isotopic composition of hydrogen through sulfur in the range up to 75 Mev/nucleon can also be resolved. The electronic systems include a dual-gain, charge sensitive preamplifier, 4096-channel pulse height analyzers for three parameter analysis of selected events, and an event type readout polling scheme to maximize the use of available telemetry space and to enhance the occurrence of rare events in the data. Details of the detector, electronic and mechanical design are presented.
Magnetic properties of a stainless steel irradiated with 6 MeV Xe ions
NASA Astrophysics Data System (ADS)
Xu, Chaoliang; Liu, Xiangbing; Qian, Wangjie; Li, Yuanfei
2017-11-01
Specimens of austenitic stainless steel were irradiated with 6 MeV Xe ions at room temperature to 2, 7, 15 and 25 dpa. The vibrating sample magnetometer (VSM), grazing incidence X-ray diffraction (GIXRD) and positron annihilation lifetime spectroscopy (PLS) were carried out to analysis the magnetic properties and microstructural variations. The magnetic hysteresis loops indicated that higher irradiation damage causes more significant magnetization phenomenon. The equivalent saturated magnetization Mes and coercive force Hc were obtained from magnetic hysteresis loops. It is indicated that the Mes increases with irradiation damage. While Hc increases first to 2 dpa and then decreases continuously with irradiation damage. The different contributions of irradiation defects and ferrite precipitates on Mes and Hc can explain these phenomena.
NASA Astrophysics Data System (ADS)
Iwamoto, Yosuke; Hagiwara, Masayuki; Matsumoto, Tetsuro; Masuda, Akihiko; Iwase, Hiroshi; Yashima, Hiroshi; Shima, Tatsushi; Tamii, Atsushi; Nakamura, Takashi
2012-10-01
Secondary neutron-production double-differential cross-sections (DDXs) have been measured from interactions of 137 MeV and 200 MeV protons in a natural carbon target. The data were measured between 0° and 25° in the laboratory. DDXs were obtained with high energy resolution in the energy region from 3 MeV up to the maximum energy. The experimental data of 137 MeV protons at 10° and 25° were in good agreement with that of 113 MeV protons at 7.5° and 30° at LANSCE/WNR in the energy region below 80 MeV. Benchmark calculations were carried out with the PHITS code using the evaluated nuclear data files of JENDL/HE-2007 and ENDF/B-VII, and the theoretical models of Bertini-GEM and ISOBAR-GEM. For the 137 MeV proton incidence, calculations using JENDL/HE-2007 generally reproduced the shape and the intensity of experimental spectra well including the ground state of the 12N state produced by the 12C(p,n)12N reaction. For the 200 MeV proton incidence, all calculated results underestimated the experimental data by the factor of two except for the calculated result using ISOBAR model. ISOBAR predicts the nucleon emission to the forward angles qualitatively better than the Bertini model. These experimental data will be useful to evaluate the carbon data and as benchmark data for investigating the validity of the Monte Carlo simulation for the shielding design of accelerator facilities.
Photoproduction of $$ \\pi^{0}$$-pairs off protons and off neutrons
Dieterle, M.; Oberle, M.; Ahrens, J.; ...
2015-11-04
Total cross sections, angular distributions, and invariant-mass distributions have been measured for the photoproduction of π 0π 0 pairs off free protons and off nucleons bound in the deuteron. The experiments were performed at the MAMI accelerator facility in Mainz using the Glasgow photon tagging spectrometer and the Crystal Ball/TAPS detector. The accelerator delivered electron beams of 1508 and 1557MeV, which produced bremsstrahlung in thin radiator foils. The tagged photon beam covered energies up to 1400MeV. The data from the free proton target are in good agreement with previous measurements and were only used to test the analysis procedures. Themore » results for differential cross sections (angular distributions and invariant-mass distributions) for free and quasi-free protons are almost identical in shape, but differ in absolute magnitude up to 15%. Thus, moderate final-state interaction effects are present. The data for quasi-free neutrons are similar to the proton data in the second resonance region (final-state invariant masses up to ≈1550 MeV), where both reactions are dominated by the N(1520)3/2 –→Δ(1232)3/2 +π decay. At higher energies, angular and invariant-mass distributions are different. A simple analysis of the shapes of the invariant-mass distributions in the third resonance region is consistent with strong contributions of an N*→Nσ decay for the proton, while the reaction is dominated by a sequential decay via a Δπ intermediate state for the neutron. Here, the data are compared to predictions from the Two-Pion-MAID model and the Bonn-Gatchina coupled-channel analysis.« less
NASA Astrophysics Data System (ADS)
Kehayias, Joseph J.; Ma, Ruimei; Zhuang, Hong; Moore, Robert; Dowling, Lisa
1995-03-01
Non-invasive in vivo elemental analysis is a technique used to assess human body composition which is indicative of nutritional status and health condition. The in vivo measurement of the body's major elements is used for a variety of medical studies requiring the determination of the body's compartments (protein, fat, water, bone). Whole body gamma-ray counters, consisting of Nal(Tl) crystal detectors in a shielded room, are used for measuring in vivo the body's Ca, Cl, Na and P by delayed neutron activation analysis. Thermal neutrons from a moderated 238Pu-Be source are used for the measurement of total body nitrogen (and thus protein) and chlorine at low radiation exposure (0.80 mSv). The resulting high energy prompt gamma-rays from nitrogen (10.83 MeV) and chlorine (6.11 MeV) are detected simultaneously with the irradiation. Body fat (the main energy store) and fat distribution (which relates to risk for cardiovascular disease) are measured by detecting C and O in vivo through fast neutron inelastic scattering. A small sealed D-T neutron generator is used for the pulsed (4 - 8 KHz) production of fast neutrons. Carbon and oxygen are detected by counting the 4.44 and 6.13 MeV gamma-rays resulting from the inelastic scattering of the fast neutrons from the 12C and 16O nuclei, respectively. One use of this method is the systematic study of the mechanisms driving the age-associated depletion of the metabolizing, oxygen-consuming cellular compartment of the body. The understanding of this catabolism may suggest ways to maintain lean tissue and thus to preserve quality of life for the very old.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mayo, S.; Rosenblatt, J.
1961-01-01
Elastic and inelastic differential cross sections in Ni(d,d)Ni with 27.6 Mev deuterons were measured with the aid of scintillation technique. Charged particle spectra from the reaction were observed at laboratory angles of 15 up to 150 degrees, showing the presence of Q-positive stripping protons and elastic and inelastic deuteron groups. Due to isotopic mixture in natural Ni and the rather high level density above 2 Mev of excitation in most of those isotopes, only inelastic deuteron groups going to the first excited states in Ni/sup 58/ and Ni/ sup 60/ could be identified. Elastic angular distribution exhibits similarities to thatmore » obtained by Yntema at 21.6 Mev, showing the typical diffraction patterns. At backward angles, a slight growing in the crosssection was observed which was not observed at 21.6 Mev. By regarding the elastic scattering like a classical light diffraction by a black disk, an interaction radius of 6.8 plus or minus 0.8 f was derived. Inelastic angular distributions were fitted by semiclassical Butler et al. theory and Huby-Newns theory. Due to above-mentioned limitations level mixtures could not be avoided; however, a group of deuterons going to Ni/ sup 58/ 1.45 Mev, probably mixed with Ni/sup 60/ 1.33 Mev, could be identified as proceeding via direct interaction with l = 2 and interaction radius 6.7 f and 6.9 f, respectively. Another inelastic group identified as Ni/sup 58/ 2.46 Mev mixed with Ni/sup 60/ 2.50 Mev is well fitted by l = 2 plus l = 4 and interaction radius 8.9 f and 8.7 f respectively, showing direct interaction behavor. Contributions to the above processes from compound nucleus formation are small as can be seen from absolute cross sections above 50 degrees. Total cross section for the formation of compound nucleus is about 860 mbarn. According to selection rules for deuteron scattering, 2/sup +/ is assigned to levels 1.45 Mev and 2.46 Mev in Ni/sup 58/; however this assignment is not definitive due to background from levels in Ni/sup 58/ and Ni/sup 60/ present at those excitation energies. (auth)« less
Observations by Juno's Radiation Monitoring Investigation During the First Year at Jupiter
NASA Astrophysics Data System (ADS)
Becker, H. N.; Adumitroaie, V.; Alexander, J. W.; Daubar, I.; Joergensen, J. L.; Denver, T.; Benn, M.; Adriani, A.; Mura, A.; Cicchetti, A.; Noschese, R.; Connerney, J. E. P.; Gladstone, R.; Hue, V.; Versteeg, M.; Santos-Costa, D.; Bolton, S. J.; Levin, S.; Thorne, R. M.
2017-12-01
Juno's Radiation Monitoring (RM) Investigation measures MeV electron fluxes at Jupiter by utilizing the noise signatures of penetrating high-energy particles which are visible in images collected by Juno's heavily shielded star cameras and science instruments. Image processing is used to identify and extract the characteristic signatures of penetrating high-energy electrons and ions and derive count rates which are used to infer external integral electron flux levels [Becker, H.N., et al. (2017), Space Sci Rev, doi: 10.1007/s11214-017-0345-9; Becker H.N. et al. (2017), Geophys. Res. Lett., 44, doi:10.1002/2017GL073091]. The count rate data from each RM instrument represents detection of electrons from within a broad energy channel (e.g. > 5 MeV or > 10 MeV electron sensitivity, determined using Geant4 shielding analysis). Simultaneous observations by the instruments therefore allow study of the external spectra where coordinated measurements are achieved. The spacecraft Stellar Reference Unit (SRU), the Magnetic Field Investigation's Advanced Stellar Compass (ASC) camera head D, and the Jovian Infrared Auroral Mapper (JIRAM) infrared imager are the primary instruments used in RM's collaborative observation campaigns. Penetrating particle signatures and trends across a broader range of Juno instruments and spacecraft housekeeping data also contribute to the analysis. This paper presents an overview of RM measurements of the Jovian high energy particle environment observed during the first eight science orbits of Juno's prime mission.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Delbar, T.; Gregoire, G.; Lega, J.
1976-10-01
The spectra from the reaction /sup 9/Be(p, ..cap alpha..)/sup 6/Li induced by 75 and 30 MeV protons were recorded at theta/sub ..cap alpha../ = 20 and 30/sup 0/ in the laboratory frame. The region from 6 to 18 MeV excitation energy of the residual nucleus was carefully studied for possible levels. Evidence for a T = 1 level at E/sub x/ = 8.2 +- 0.2 MeV with a width GAMMA = 2.2 +- 0.2 MeV is reported. No other levels were observed in the present spectra. (AIP)
The JPL Uranian Radiation Model (UMOD)
NASA Technical Reports Server (NTRS)
Garrett, Henry; Martinez-Sierra, Luz Maria; Evans, Robin
2015-01-01
The objective of this study is the development of a comprehensive radiation model (UMOD) of the Uranian environment for JPL mission planning. The ultimate goal is to provide a description of the high energy electron and proton environments and the magnetic field at Uranus that can be used for engineering design. Currently no model exists at JPL. A preliminary electron radiation model employing Voyager 2 data was developed by Selesnick and Stone in 1991. The JPL Uranian Radiation Model extends that analysis, which modeled electrons between 0.7 MeV and 2.5 MeV based on the Voyager Cosmic Ray Subsystem electron telescope, down to an energy of 0.022 MeV for electrons and from 0.028 MeV to 3.5 MeV for protons. These latter energy ranges are based on measurements by the Applied Physics Laboratory Low Energy Charged Particle Detector on Voyager 2. As in previous JPL radiation models, the form of the Uranian model is based on magnetic field coordinates and requires a conversion from spacecraft coordinates to Uranian-centered magnetic "B-L" coordinates. Two magnetic field models have been developed for Uranus: 1) a simple "offset, tilted dipole" (OTD), and 2) a complex, multi-pole expansion model ("Q3"). A review of the existing data on Uranus and a search of the NASA Planetary Data System (PDS) were completed to obtain the latest, up to date descriptions of the Uranian high energy particle environment. These data were fit in terms of the Q3 B-L coordinates to extend and update the original Selesnick and Stone electron model in energy and to develop the companion proton flux model. The flux predictions of the new model were used to estimate the total ionizing dose for the Voyager 2 flyby, and a movie illustrating the complex radiation belt variations was produced to document the uses of the model for planning purposes.
2014-06-01
BEAMnrc Monte Carlo (MC) codes were used to simulate 50- 150MeV VHEE beam dose deposition and its effects on steel and titanium (Ti) heterogeneities in a...performed on water-only geometry and water with segmented prostheses ( steel and Ti) geometries with 100MeV and 150MeV beams...8 Results: 100MeV PDD 5cm behind steel /Ti heterogeneity was 51% less than in the
Neutron production from 200-500 MeV proton interaction with spacecraft materials.
Maurer, Richard H; Kinnison, James D; Roth, David R
2005-01-01
We report on detailed energy spectra of neutron production > 14 MeV from collisions of 200-500 MeV protons with combinations of aluminium, graphite and polyethylene. Comparisons of normalised neutron spectra are made with respect to incident proton energy, angle of neutron production and material. In general, carbon (graphite) or polyethylene (by itself or in combination with aluminium) reduce secondary neutron production > 14 MeV relative to the production from interactions in aluminium.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bakar, Khomsaton Abu; Zulkafli,; Hashim, Siti A'aisah
2014-09-03
In this study, electron beam accelerator (EB) was used to treat textiles wastewater from Rawang Industrial Park, Selangor. The objectives were to determine effective energy, beam current and absorbed dose required for decoloration and degradation of the textiles effluent. The textiles effluent was irradiated in a batch with various energy of 1MeV to 3MeV at constant beam current of 30mA. It was observed that removal of color and COD increases with higher beam energy. The EB energy of 1MeV effectively to removed 58% color and 19% COD. For textile effluent sample irradiated at fix energy of 1MeV and 3Mev butmore » at different beam current 10mA, 20mA and 30mA. It was observed that removal of color and COD increases with the increased of beam current at each energy. However removal of color was significantly better at 1Mev as compared to 3Mev. In the case of textiles effluent, irradiated at doses of 17, 20,25,30, 35, 100 and 200kGy using 30 kW power of EB (1Mev, 30mA), results shows removal of BOD{sub 5}, COD and color were in the range 9%-33%, 14%-38% and 43%-78% respectively.« less
A finite element simulation of sound attenuation in a finite duct with a peripherally variable liner
NASA Technical Reports Server (NTRS)
Watson, W. R.
1977-01-01
Using multimodal analysis, a variational finite element method is presented for analyzing sound attenuation in a three-dimensional finite duct with a peripherally variable liner in the absence of flow. A rectangular element, with cubic shaped functions, is employed. Once a small portion of a peripheral liner is removed, the attenuation rate near the frequency where maximum attenuation occurs drops significantly. The positioning of the liner segments affects the attenuation characteristics of the liner. Effects of the duct termination are important in the low frequency ranges. The main effect of peripheral variation of the liner is a broadening of the attenuation characteristics in the midfrequency range. Because of matrix size limitations of the presently available computer program, the eigenvalue equations should be solved out of core in order to handle realistic sources.
The evaluation of experimental data in fast range for n + 56Fe(n,inl)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Qian, Jing; Herman, M.; Ge, Zhigang
Iron is one of the five materials selected for evaluation within the pilot international evaluation project CIELO. Analysis of experimental data for n+ 56Fe reaction is the basis for constraining theoretical calculations and eventual creation of the evaluated file. The detail analysis was performed for inelastic cross sections of neutron induced reactions with 56Fe in the fast range up to 20 MeV where there are significant differences among the main evaluated libraries, mainly caused by the different inelastic scattering cross section measurements. Gamma-ray production cross sections provide a way to gain experimental information about the inelastic cross section. Large discrepanciesmore » between experimental data for the 847-keV gamma ray produced in the 56Fe(n,n 1'γ) reaction were analyzed. In addition, experimental data for elastic scattering cross section between 9.41~11 MeV were used to deduce the inelastic cross section from the unitarity constrain.« less
The evaluation of experimental data in fast range for n + 56Fe(n,inl)
Qian, Jing; Herman, M.; Ge, Zhigang; ...
2017-09-13
Iron is one of the five materials selected for evaluation within the pilot international evaluation project CIELO. Analysis of experimental data for n+ 56Fe reaction is the basis for constraining theoretical calculations and eventual creation of the evaluated file. The detail analysis was performed for inelastic cross sections of neutron induced reactions with 56Fe in the fast range up to 20 MeV where there are significant differences among the main evaluated libraries, mainly caused by the different inelastic scattering cross section measurements. Gamma-ray production cross sections provide a way to gain experimental information about the inelastic cross section. Large discrepanciesmore » between experimental data for the 847-keV gamma ray produced in the 56Fe(n,n 1'γ) reaction were analyzed. In addition, experimental data for elastic scattering cross section between 9.41~11 MeV were used to deduce the inelastic cross section from the unitarity constrain.« less
PIGE-PIXE analysis of human milk
NASA Astrophysics Data System (ADS)
Olabanji, S. O.; Buoso, M. C.; Ceccato, D.; Haque, A. M. I.; Cherubini, R.; Moschini, G.
1996-04-01
PIGE-PIXE nuclear techniques were employed for the determination of the elemental composition of human breast milk which is the main source of nutrients to babies in Nigeria. Samples were collected from 32 healthy lactating mothers from Obafemi Awolowo Teaching University Hospital, Ile-Ife, Nigeria. The samples were homogenized and immediately frozen, and then freeze-dried. Pellets were made using a Perkin Elmer instrument and its accessory the 13 mm die. PIGE measurements of light elements were performed using 3.5 MeV collimated protons from the 7 MV CN Van de Graaff accelerator of INFN, LNL, Legnaro (Padova) Italy while PIXE analysis was carried out using 1.8 MeV collimated proton beam from the 2.5 MV AN 2000 Van de Graaff accelerator of the same Institute. The results show the presence of important elements that are essential for growth and development of babies. We searched for certain toxic elements which include As, Cd, Hg, Pb, etc. because of their negative roles in enhancing infant mortality rates, but none of them was detected except Pb.
Infrared attenuation of thallium bromo-iodide fibers
NASA Technical Reports Server (NTRS)
Magilavy, B.; Goebel, J.
1986-01-01
Analysis of attenuation measurements in the near infrared of an unclad fiber of Thallium Bromo-Iodide (Th(Br,I)), a polycrystalline thallium halide, is presented. A general overview is given of the properties of fiber optics. Two groups of attenuation measurements, for the region 1.2 to 3.4 and for 3 to 11 microns, respectively, are presented, analyzed, and compared with those of two other groups of researchers.
Electron Effective-Attenuation-Length Database
National Institute of Standards and Technology Data Gateway
SRD 82 NIST Electron Effective-Attenuation-Length Database (PC database, no charge) This database provides values of electron effective attenuation lengths (EALs) in solid elements and compounds at selected electron energies between 50 eV and 2,000 eV. The database was designed mainly to provide EALs (to account for effects of elastic-eletron scattering) for applications in surface analysis by Auger-electron spectroscopy (AES) and X-ray photoelectron spectroscopy (XPS).
High and Low Energy Proton Radiation Damage in p/n InP MOCVD Solar Cells
NASA Technical Reports Server (NTRS)
Rybicki, George; Weinberg, Irv; Scheiman, Dave; Vargas-Aburto, Carlos; Uribe, Roberto
1995-01-01
InP p(+)/n/n(+) solar cells, fabricated by metal organic chemical vapor deposition, (MOCVD) were irradiated with 0.2 MeV and 10 MeV protons to a fluence of 10(exp 13)/sq cm. The power output degradation, IV behavior, carrier concentration and defect concentration were observed at intermediate points throughout the irradiations. The 0.2 MeV proton-irradiated solar cells suffered much greater and more rapid degradation in power output than those irradiated with 10 MeV protons. The efficiency losses were accompanied by larger increases in the recombination currents in the 0.2 MeV proton-irradiated solar cells. The low energy proton irradiations also had a larger impact on the series resistance of the solar cells. Despite the radiation induced damage, the carrier concentration in the base of the solar cells showed no reduction after 10 MeV or 0.2 MeV proton irradiations and even increased during irradiation with 0.2 MeV protons. In a deep level transient spectroscopy (DLTS) study of the irradiated samples, the minority carrier defects H4 and H5 at E(sub v) + 0.33 and E(sub v) + 0.52 eV and the majority carrier defects E7 and El0 at E(sub c) - 0.39 and E(sub c) - 0.74 eV, were observed. The defect introduction rates for the 0.2 MeV proton irradiations were about 20 times higher than for the 10 MeV proton irradiations. The defect El0, observed here after irradiation, has been shown to act as a donor in irradiated n-type InP and may be responsible for obscuring carrier removal. The results of this study are consistent with the much greater damage produced by low energy protons whose limited range causes them to stop in the active region of the solar cell.
Radiological properties of normoxic polymer gel dosimeters
DOE Office of Scientific and Technical Information (OSTI.GOV)
Venning, A.J.; Nitschke, K.N.; Keall, P.J.
2005-04-01
The radiological properties of the normoxic polymer gel dosimeters MAGIC, MAGAS, and MAGAT [methacrylic and ascorbic acid in gelatin initiated by copper; methacrylic acid gelatine gel with ascorbic acid; and methacrylic acid gelatine and tetrakis (hydroxymethyl) phosphonium chloride, respectively] have been investigated. The radiological water equivalence was determined by comparing the polymer gel macroscopic photon and electron interaction cross sections over the energy range from 10 keV to 20 MeV and by Monte Carlo modeling of depth doses. Normoxic polymer gel dosimeters have a high gelatine and monomer concentration and therefore mass density (kg m{sup -3}) up to 3.8% highermore » than water. This results in differences between the cross-section ratios of the normoxic polymer gels and water of up to 3% for the attenuation, energy absorption, and collision stopping power coefficient ratios through the Compton dominant energy range. The mass cross-section ratios were within 2% of water except for the mass attenuation and energy absorption coefficients ratios, which showed differences with water of up to 6% for energies less than 100 keV. Monte Carlo modeling was undertaken for the polymer gel dosimeters to model the electron and photon transport resulting from a 6 MV photon beam. The absolute percentage differences between gel and water were within 1% and the relative percentage differences were within 3.5%. The results show that the MAGAT gel formulation is the most radiological water equivalent of the normoxic polymer gel dosimeters investigated due to its lower mass density measurement compared with MAGAS and MAGIC gels.« less
Khezerloo, Davood; Nedaie, Hassan Ali; Takavar, Abbas; Zirak, Alireza; Farhood, Bagher; Banaee, Nooshin; Alidokht, Eisa
2018-01-01
Tin-base catalyst is one of the widely used organometallic catalysts in polyurethane technology. The purpose of this study was to evaluate the effect of tin organometallic catalyst in the radiation response and radiological properties of a new formula of PRESAGE ® . In the study, two types of PRESAGE were fabricated. A very little amount of dibutyltindillaurate (DBTDL) (0.07% weight) was used as a catalyst in the fabrication of new PRESAGE (i.e., PRESAGE with catalyst), which components were: 93.93% weight polyurethane, 5% weight tetrachloride, and 1% weight leucomalachite green (LMG). For PRESAGE without catalyst, 94% weight polyurethane, 4% weight tetrachloride, and 2% weight LMG were used. Radiochromic response and postirradiation stability of PRESAGEs were determined. Also, radiological characteristics of PRESAGEs, such as mass density, electron density, mass attenuation coefficient, and mass stopping power in different photon energies were assessed and compared with water. The absorption peak of new PRESAGE compared to PRESAGE without catalyst was observed without change. Sensitivity of new PRESAGE was higher than PRESAGE without catalyst and its stability after the first 1 h was relatively constant. Also, Mass attenuation coefficient of new PRESAGE in energy ranges <0.1 MeV was 10% more than water, whereas the maximum difference of mass stopping power was only 3%. Tin organometallic catalyst in very low concentration can be used in fabrication of radiochromic polymer gel to achieve high sensitivity and stability as well as good radiological properties in the megavoltage photon beam.
GALACTIC COSMIC RAYS IN THE LOCAL INTERSTELLAR MEDIUM: VOYAGER 1 OBSERVATIONS AND MODEL RESULTS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cummings, A. C.; Stone, E. C.; Heikkila, B. C.
Since 2012 August Voyager 1 has been observing the local interstellar energy spectra of Galactic cosmic-ray nuclei down to 3 MeV nuc{sup -1} and electrons down to 2.7 MeV. The H and He spectra have the same energy dependence between 3 and 346 MeV nuc{sup -1}, with a broad maximum in the 10–50 MeV nuc{sup -1} range and a H/He ratio of 12.2 ± 0.9. The peak H intensity is ∼15 times that observed at 1 AU, and the observed local interstellar gradient of 3–346 MeV H is -0.009 ± 0.055% AU{sup -1}, consistent with models having no local interstellarmore » gradient. The energy spectrum of electrons ( e {sup -} + e {sup +}) with 2.7–74 MeV is consistent with E {sup -1.30±0.05} and exceeds the H intensity at energies below ∼50 MeV. Propagation model fits to the observed spectra indicate that the energy density of cosmic-ray nuclei with >3 MeV nuc{sup -1} and electrons with >3 MeV is 0.83–1.02 eV cm{sup -3} and the ionization rate of atomic H is in the range of 1.51–1.64 × 10{sup -17} s{sup -1}. This rate is a factor >10 lower than the ionization rate in diffuse interstellar clouds, suggesting significant spatial inhomogeneity in low-energy cosmic rays or the presence of a suprathermal tail on the energy spectrum at much lower energies. The propagation model fits also provide improved estimates of the elemental abundances in the source of Galactic cosmic rays.« less
Three-fold increase of M1 strength in 40Ar at 10 MeV excitation energy
NASA Astrophysics Data System (ADS)
Tornow, Werner; Finch, Sean; Krishichayan, Fnu; Tonchev, Anton
2017-09-01
We reexamined the excitation energy region of 40Ar around 9.8 MeV with the goal of determining the known M1 strength located at 9.76 MeV more accurately. The physics motivation was based on the fact that i) the neutrino-nucleus interaction cross section is proportional to the M1 strength of a nucleus, ii) DUNE, the Deep Underground Neutrino Experiment at SURF will be using liquid argon as detector medium, iii) the energy spectrum of supernova neutrinos is peaked at approximately 10 MeV. Mono-energetic and linearly polarized photons of 9.88 MeV were produced via Compton backscattering of 548 nm FEL photons from 543 MeV electrons at the High-Intensity γ-ray Source (HI γS) facility at TUNL. The 1.25 cm diameter photon beam with energy spread of 300 keV (FWHM) interacted with argon gas contained in a high-pressure cell. The cell was viewed with HPGe detectors placed at 90o relative to the incident photon beam in the horizontal and vertical planes to distinguish between E1 and M1 de-excitation γ-rays. Our re-measurement provided an increase in M1 strength by a factor of approximately 3, mostly due to the discovery that the known level in 40Ar at 9.84 MeV is of M1 character and not of E1 character, as previously thought. In addition to the already known M1 state at 9.76 MeV, we observed weaker M1 states at 9.70, 9.81, 9.87, and 9.89 MeV.
NASA Astrophysics Data System (ADS)
Troitskaia, E.; Arkhangelskaja, I.; Arkhangelsky, A.; Gan, W.
2013-02-01
Basing on the data of AVS-F apparatus from SONG-D detector onboard CORONAS-F satellite, we have studied the extreme solar event of January 20, 2005 used the 2.223 MeV, 4.44 MeV and 6.13 MeV γ-lines temporal profiles. By the statistical modeling method we calculated the temporal profile of 2.223 MeV line too. Calculations have been performed in assumption of Bessel type of accelerated particles energy spectrum, different 3He content in the region of nuclear reactions and several density models of the solar atmosphere. Comparisons of the results of modeling with observational 2.223 MeV AVS-F/SONG-D data reveal the increasing of the ratio of 3He concentration to 1H one during the flare from 2× 10-5 at the rise phase of the gamma-ray flux up to 2× 10--4 at the decay one. During the same period the spectrum became harder and the density of solar atmosphere increased too. Averaged over full time of 2.223 MeV γ-emission concentration ratio of 3He/1H is equal to (1.40±0.15)×10--4, also the density model with enlarged density up to 2×1017 cm-3 in the lower chromosphere and through the whole photosphere is realized. Besides, we have estimated the spectral index αT that is close to 0.1 for accelerated protons in the range of 1-100 MeV. Using the AVS-F gamma-rays spectral data in the wide range up to 140 MeV, we have obtained the spectral index of s=2.5±0.1 in the case of power law spectrum for energies more than 300 MeV.
Photo-fission Product Yield Measurements at Eγ=13 MeV on 235U, 238U, and 239Pu
NASA Astrophysics Data System (ADS)
Tornow, W.; Bhike, M.; Finch, S. W.; Krishichayan, Fnu; Tonchev, A. P.
2016-09-01
We have measured Fission Product Yields (FPYs) in photo-fission of 235U, 238U, and 239Pu at TUNL's High-Intensity Gamma-ray Source (HI γS) using mono-energetic photons of Eγ = 13 MeV. Details of the experimental setup and analysis procedures will be discussed. Yields for approximately 20 fission products were determined. They are compared to neutron-induced FPYs of the same actinides at the equivalent excitation energies of the compound nuclear systems. In the future photo-fission data will be taken at Eγ = 8 . 0 and 10.5 MeV to find out whether photo-fission exhibits the same so far unexplained dependence of certain FPYs on the energy of the incident probe, as recently observed in neutron-induced fission, for example, for the important fission product 147Nd. Work supported by the U. S. Dept. of Energy, under Grant No. DE-FG02-97ER41033, and by the NNSA, Stewardship Science Academic Alliances Program, Grant No. DE-NA0001838 and the Lawrence Livermore, National Security, LLC under Contract No. DE-AC52-07NA27344.
NASA Astrophysics Data System (ADS)
Losekamm, M. J.; Milde, M.; Pöschl, T.; Greenwald, D.; Paul, S.
2017-02-01
Traditional radiation detectors can either measure the total radiation dose omnidirectionally (dosimeters), or determine the incoming particles characteristics within a narrow field of view (spectrometers). Instantaneous measurements of anisotropic fluxes thus require several detectors, resulting in bulky setups. The Multi-purpose Active-target Particle Telescope (MAPT), employing a new detection principle, is designed to measure particle fluxes omnidirectionally and be simultaneously a dosimeter and spectrometer. It consists of an active core of scintillating fibers whose light output is measured by silicon photomultipliers, and fits into a cube with an edge length of 10 cm. It identifies particles using extended Bragg curve spectroscopy, with sensitivity to charged particles with kinetic energies above 25 MeV. MAPT's unique layout results in a geometrical acceptance of approximately 800 cm2 sr and an angular resolution of less than 6°, which can be improved by track-fitting procedures. In a beam test of a simplified prototype, the energy resolution was found to be less than 1 MeV for protons with energies between 30 and 70 MeV. Possible applications of MAPT include the monitoring of radiation environments in spacecraft and beam monitoring in medical facilities.
NASA Technical Reports Server (NTRS)
Kim, Myung-Hee; Atwell, William; Tylka, Allan J.; Dietrich, William F.; Cucinotta, Francis A.
2010-01-01
For radiation dose assessments of major solar particle events (SPEs), spectral functional forms of SPEs have been made by fitting available satellite measurements up to approx.100 MeV. However, very high-energy protons (above 500 MeV) have been observed with neutron monitors (NMs) in ground level enhancements (GLEs), which generally present the most severe radiation hazards to astronauts. Due to technical difficulties in converting NM data into absolutely normalized fluence measurements, those functional forms were made with little or no use of NM data. A new analysis of NM data has found that a double power law in rigidity (the so-called Band function) generally provides a satisfactory representation of the combined satellite and NM data from approx.10 MeV to approx.10 GeV in major SPEs (Tylka & Dietrich 2009). We use the Band function fits to re-assess human exposures from large SPEs. Using different spectral representations of large SPEs, variations of exposure levels were compared. The results can be applied to the development of approaches of improved radiation protection for astronauts, as well as the optimization of mission planning and shielding for future space missions.
The solar gamma ray and neutron capabilities of COMPTEL on the Gamma Ray Observatory
NASA Technical Reports Server (NTRS)
Ryan, James M.; Lockwood, John A.
1989-01-01
The imaging Compton telescope COMPTEL on the Gamma Ray Observatory (GRO) has unusual spectroscopic capabilities for measuring solar gamma-ray and neutron emission. The launch of the GRO is scheduled for June 1990 near the peak of the sunspot cycle. With a 30 to 40 percent probability for the Sun being in the COMPTEL field-of-view during the sunlit part of an orbit, a large number of flares will be observed above the 800 keV gamma-ray threshold of the telescope. The telescope energy range extends to 30 MeV with high time resolution burst spectra available from 0.1 to 10 MeV. Strong Compton tail suppression of instrumental gamma-ray interactions will facilitate improved spectral analysis of solar flare emissions. In addition, the high signal to noise ratio for neutron detection and measurement will provide new neutron spectroscopic capabilities. Specifically, a flare similar to that of 3 June 1982 will provide spectroscopic data on greater than 1500 individual neutrons, enough to construct an unambiguous spectrum in the energy range of 20 to 200 MeV. Details of the instrument and its response to solar gamma-rays and neutrons will be presented.
NASA Astrophysics Data System (ADS)
Jamieson, D. S.; Garrett, P. E.; Ball, G. C.; Demand, G. A.; Faestermann, T.; Finlay, P.; Green, K. L.; Hertenberger, R.; Krücken, R.; Leach, K. G.; Phillips, A. A.; Sumithrarachchi, C. S.; Triambak, S.; Wirth, H.-F.
2014-03-01
Cadmium isotopes have been presented for decades as excellent examples of vibrational nuclei, with low-lying levels interpreted as multi-phonon quadrupole, octupole, and mixed-symmetry states. A large amount of spectroscopic data has been obtained through various experimental studies of cadmiumisotopes. In the present work, the 111Cd(overrightarrow {{d}} ,p)112Cd reaction was used to investigate the single-particle structure of the 112Cd nucleus. A 22 MeV beam of polarized deuterons was obtained at the Maier-Leibnitz laboratory in Garching, Germany. The reaction ejectiles were momentum analyzed using a Q3D spectrograph, and 130 levels have been identified up to 4.2 MeV of excitation energy. Using DWBA analysis with optical model calculations, spin-parity assignments have been made for observed levels, and spectroscopic factors have been extracted from the experimental angular distributions of differential cross section and analyzing power. In this high energy resolution investigation, many additional levels have been observed compared with the previous (d,p) study using 8 MeV deuterons [1]. There were a total of 44 new levels observed, and the parity assignments of 34 levels were improved.
Fusion product losses due to fishbone instabilities in deuterium JET plasmas
NASA Astrophysics Data System (ADS)
Kiptily, V. G.; Fitzgerald, M.; Goloborodko, V.; Sharapov, S. E.; Challis, C. D.; Frigione, D.; Graves, J.; Mantsinen, M. J.; Beaumont, P.; Garcia-Munoz, M.; Perez von Thun, C.; Rodriguez, J. F. R.; Darrow, D.; Keeling, D.; King, D.; McClements, K. G.; Solano, E. R.; Schmuck, S.; Sips, G.; Szepesi, G.; Contributors, JET
2018-01-01
During development of a high-performance hybrid scenario for future deuterium-tritium experiments on the Joint European Torus, an increased level of fast ion losses in the MeV energy range was observed during the instability of high-frequency n = 1 fishbones. The fishbones are excited during deuterium neutral beam injection combined with ion cyclotron heating. The frequency range of the fishbones, 10-25 kHz, indicates that they are driven by a resonant interaction with the NBI-produced deuterium beam ions in the energy range ⩽120 keV. The fast particle losses in a much higher energy range are measured with a fast ion loss detector, and the data show an expulsion of deuterium plasma fusion products, 1 MeV tritons and 3 MeV protons, during the fishbone bursts. An MHD mode analysis with the MISHKA code combined with the nonlinear wave-particle interaction code HAGIS shows that the loss of toroidal symmetry caused by the n = 1 fishbones affects strongly the confinement of non-resonant high energy fusion-born tritons and protons by perturbing their orbits and expelling them. This modelling is in a good agreement with the experimental data.
Reaction πN → ππN near threshold
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frlez, Emil
1993-11-01
The LAMPF E1179 experiment used the π 0 spectrometer and an array of charged particle range counters to detect and record π +π 0, π 0p, and π +π 0p coincidences following the reaction π +p → π 0π +p near threshold. The total cross sections for single pion production were measured at the incident pion kinetic energies 190, 200, 220, 240, and 260 MeV. Absolute normalizations were fixed by measuring π +p elastic scattering at 260 MeV. A detailed analysis of the π 0 detection efficiency was performed using cosmic ray calibrations and pion single charge exchange measurements with a 30 MeV π - beam. All published data on πN → ππN, including our results, are simultaneously fitted to yield a common chiral symmetry breaking parameter ξ =-0.25±0.10. The threshold matrix element |α 0(π 0π +p)| determined by linear extrapolation yields the value of the s-wave isospin-2 ππ scattering length αmore » $$2\\atop{0}$$(ππ) = -0.041±0.003 m$$-1\\atop{π}$$ -1, within the framework of soft-pion theory.« less
Computational comparison of quantum-mechanical models for multistep direct reactions
NASA Astrophysics Data System (ADS)
Koning, A. J.; Akkermans, J. M.
1993-02-01
We have carried out a computational comparison of all existing quantum-mechanical models for multistep direct (MSD) reactions. The various MSD models, including the so-called Feshbach-Kerman-Koonin, Tamura-Udagawa-Lenske and Nishioka-Yoshida-Weidenmüller models, have been implemented in a single computer system. All model calculations thus use the same set of parameters and the same numerical techniques; only one adjustable parameter is employed. The computational results have been compared with experimental energy spectra and angular distributions for several nuclear reactions, namely, 90Zr(p,p') at 80 MeV, 209Bi(p,p') at 62 MeV, and 93Nb(n,n') at 25.7 MeV. In addition, the results have been compared with the Kalbach systematics and with semiclassical exciton model calculations. All quantum MSD models provide a good fit to the experimental data. In addition, they reproduce the systematics very well and are clearly better than semiclassical model calculations. We furthermore show that the calculated predictions do not differ very strongly between the various quantum MSD models, leading to the conclusion that the simplest MSD model (the Feshbach-Kerman-Koonin model) is adequate for the analysis of experimental data.
A search for gamma rays of 1.5-20.0 MeV from Centaurus A
NASA Technical Reports Server (NTRS)
O'Neill, Terrence; Tumer, O. Tumay; Zych, Allen; White, R. Stephen
1989-01-01
A search for a gamma-ray continuum and lines from Centaurus A is reported. No measurable gamma rays are found in the 1.5-20.0 MeV and 3 sigma upper limits are reported for various energies which are about a factor of two lower than the results reported by von Ballmoos et al. (1987). These upper limits, along with those of SAS 2 and COS B, suggest that the energy distribution turns over in the energy range of 500 keV to a few MeV. A high source temperature of 5 MeV or synchrotron self-Compton models for producing an excess of gamma rays of a few MeV do not appear necessary.
The Proposed 2 MeV Electron Cooler for COSY
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dietrich, Juergen; Parkhomchuk, Vasily V.; Reva, Vladimir B.
2006-03-20
The design, construction and installation of a 2 MeV electron cooling system for COSY is proposed to further boost the luminosity even with strong heating effects of high-density internal targets. In addition the design of the 2 MeV electron cooler for COSY is intended to test some new features of the high energy electron cooler for HESR at GSI. The design of the 2 MeV electron cooler will be accomplished in cooperation with the Budker Institute of Nuclear Physics in Novosibirsk, Russia. Starting with the boundary conditions of the existing electron cooler at COSY the requirements and a first generalmore » scheme of the 2 MeV electron cooler are described.« less
Measurements of the decay of the Z 0 into lepton pairs
NASA Astrophysics Data System (ADS)
Akrawy, M. Z.; Alexander, G.; Allison, J.; Allport, P. P.; Anderson, K. J.; Armitage, J. C.; Arnison, G. T. J.; Ashton, P.; Azuelos, G.; Baines, J. T. M.; Ball, A. H.; Banks, J.; Barker, G. J.; Barlow, R. J.; Batley, J. R.; Bavaria, G.; Beard, C.; Beck, F.; Bell, K. W.; Bella, G.; Bethke, S.; Biebel, O.; Bloodworth, I. J.; Bock, P.; Boerner, H.; Breuker, H.; Brown, R. M.; Brun, R.; Buijs, A.; Burckhart, H. J.; Capiluppi, P.; Carnegie, R. K.; Carter, A. A.; Carter, J. R.; Chang, C. Y.; Charlton, D. G.; Chrin, J. T. M.; Cohen, I.; Conboy, J. E.; Couch, M.; Coupland, M.; Cuffiani, M.; Dado, S.; Dallavalle, G. M.; Davies, O. W.; Deninno, M. M.; Dieckmann, A.; Dittmar, M.; Dixit, M. S.; Duchesneau, D.; Duchovni, E.; Duerdoth, I. P.; Dumas, D.; El Mamouni, H.; Elcombe, P. A.; Estabrooks, P. G.; Fabbri, F.; Farthouat, P.; Fischer, H. M.; Fong, D. G.; French, M. T.; Fukunaga, C.; Gandois, B.; Ganel, O.; Gary, J. W.; Geddes, N. I.; Gee, C. N. P.; Geich-Gimbel, C.; Gensler, S. W.; Gentit, F. X.; Giacomelli, G.; Gibson, W. R.; Gillies, J. D.; Goldberg, J.; Goodrick, M. J.; Gorn, W.; Granite, D.; Gross, E.; Grosse-Wiesmann, P.; Grunhaus, J.; Hagedorn, H.; Hagemann, J.; Hansroul, M.; Hargrove, C. K.; Hart, J.; Hattersley, P. M.; Hatzifotiadou, D.; Hauschild, M.; Hawkes, C. M.; Heflin, E.; Heintze, J.; Hemingway, R. J.; Heuer, R. D.; Hill, J. C.; Hillier, S. J.; Hinde, P. S.; Ho, C.; Hobbs, J. D.; Hobson, P. R.; Hochman, D.; Holl, B.; Homer, R. J.; Hou, S. R.; Howarth, C. P.; Hughes-Jones, R. E.; Igo-Kemenes, P.; Imori, M.; Imrie, D. C.; Jawahery, A.; Jeffreys, P. W.; Jeremie, H.; Jimack, M.; Jin, E.; Jobes, M.; Jones, R. W. L.; Jovanovic, P.; Karlen, D.; Kawagoe, K.; Kawamoto, T.; Kellogg, R. G.; Kennedy, B. W.; Kleinwort, C.; Klem, D. E.; Knop, G.; Kobayashi, T.; Köpke, L.; Kokott, T. P.; Koshiba, M.; Kowalewski, R.; Kreutzmann, H.; von Krogh, J.; Kroll, J.; Kyberd, P.; Lafferty, G. D.; Lamarche, F.; Larson, W. J.; Lasota, M. M. B.; Layter, J. G.; Le Du, P.; Leblanc, P.; Lellouch, D.; Lennert, P.; Lessard, L.; Levinson, L.; Lloyd, S. L.; Loebinger, F. K.; Lorah, J. M.; Lorazo, B.; Losty, M. J.; Ludwig, J.; Lupu, N.; Ma, J.; Macbeth, A. A.; Mannelli, M.; Marcellini, S.; Maringer, G.; Martin, J. P.; Mashimo, T.; Mättig, P.; Maur, U.; McMahon, T. J.; McPherson, A. C.; Meijers, F.; Menszner, D.; Merritt, F. S.; Mes, H.; Michelini, A.; Middleton, R. P.; Mikenberg, G.; Miller, D. J.; Milstene, C.; Minowa, M.; Mohr, W.; Montanari, A.; Mori, T.; Moss, M. W.; Muller, A.; Murphy, P. G.; Murray, W. J.; Nellen, B.; Nguyen, H. H.; Nozaki, M.; O'Dowd, A. J. P.; O'Neale, S. W.; O'Neill, B.; Oakham, F. G.; Odorici, F.; Ogg, M.; Oh, H.; Oreglia, M. J.; Orito, S.; Patrick, G. N.; Pawley, S. J.; Perez, A.; Pilcher, J. E.; Pinfold, J. L.; Plane, D. E.; Poli, B.; Possoz, A.; Pouladdej, A.; Pritchard, T. W.; Quast, G.; Raab, J.; Redmond, M. W.; Rees, D. L.; Regimbald, M.; Riles, K.; Roach, C. M.; Roehner, F.; Rollnik, A.; Roney, J. M.; Rossi, A. M.; Routenburg, P.; Runge, K.; Runolfsson, O.; Sanghera, S.; Sansum, R. A.; Sasaki, M.; Saunders, B. J.; Schaile, A. D.; Schaile, O.; Schappert, W.; Scharff-Hansen, P.; von der Schmitt, H.; Schreiber, S.; Schwarz, J.; Shapira, A.; Shen, B. C.; Sherwood, P.; Simon, A.; Siroli, G. P.; Skuja, A.; Smith, A. M.; Smith, T. J.; Snow, G. A.; Spreadbury, E. J.; Springer, R. W.; Sproston, M.; Stephens, K.; Stier, H. E.; Ströhmer, R.; Strom, D.; Takeda, H.; Takeshita, T.; Tsukamoto, T.; Turner, M. F.; Tysarczyk, G.; van den Plas, D.; Vandalen, G. J.; Virtue, C. J.; Wagner, A.; Wahl, C.; Wang, H.; Ward, C. P.; Ward, D. R.; Waterhouse, J.; Watkins, P. M.; Watson, A. T.; Watson, N. K.; Weber, M.; Weisz, S.; Wermes, N.; Weymann, M.; Wilson, G. W.; Wilson, J. A.; Wingerter, I.; Winterer, V.-H.; Wood, N. C.; Wotton, S.; Wuensch, B.; Wyatt, T. R.; Yaari, R.; Yamashita, H.; Yang, Y.; Yekutieli, G.; Zeuner, W.; Zorn, G. T.; Zylberajch, S.; OPAL Collaboration
1990-02-01
We report on a measurement of the processes e +e -→e +e -, e +e -→ μ+μ-, and e +e -→ τ+τ- near the Z 0 pole. On the basis of 163 e +e -, 101 μ+μ- and 87 τ+τ- events we obtain Γee=89±4±4 MeV, Γμμ=85±9±6 MeV and Γττ=87±10±8 MeV, compatible with the standard model. Combining these with our previous results on hadronic Z 0 decays, we find a hadronic width Γhad=1787±81±90 MeV and an invisible width Γinv=552±85±71 MeV.
NASA Astrophysics Data System (ADS)
Andrews, P. R.; Shute, G. G.; Spicer, B. M.; Collins, S. F.; Officer, V. C.; Wastell, J. M.; Nann, H.; Devins, D. W.; LI, Qingli; Jones, W. P.; Olmer, C.; Bacher, A. D.; Emery, G. T.
1986-11-01
Differential cross sections were measured for the 13C(α, p) 16N reaction at Eα = 118 MeV for an excitation energy range up to 14.5 MeV. Zero-range distorted wave Born approximation (DWBA) calculations were performed using microscopic form factors. Spin-parity assignments are suggested for states at 11.21 MeV (6 -) and 11.81 MeV (7 -) on the basis of Bansal-French-Zamick weak coupling calculations and DWBA calculations. Arguments from 16O(e, e'), 16O(p, p') and the present experiment are given relating to the location of Jπ = 4 -, T = 1 strength in 16N.
Son, Ho Anh; Zhang, LiFeng; Cuong, Bui Khac; Van Tong, Hoang; Cuong, Le Duy; Hang, Ngo Thu; Nhung, Hoang Thi My; Yamamoto, Naoki; Toan, Nguyen Linh
2018-02-07
Oncolytic measles and mumps viruses (MeV, MuV) have a potential for anti-cancer treatment. We examined the anti-tumor activity of MeV, MuV, and MeV-MuV combination (MM) against human solid malignancies (HSM). MeV, MuV, and MM targeted and significantly killed various cancer cell lines of HSM but not normal cells. MM demonstrated a greater anti-tumor effect and prolonged survival in a human prostate cancer xenograft tumor model compared to MeV and MuV. MeV, MuV, and MM significantly induced the expression of immunogenic cell death markers and enhanced spleen-infiltrating immune cells. In conclusion, MM combination significantly improves the treatment of human solid malignancies.
Site Characterization for MNA of Radionuclides in Ground Water
Monitored natural attenuation is often evaluated as a component of the remedy for ground water contaminated with radionuclides. When properly employed, monitored natural attenuation (MNA) may provide an effective knowledge-based remedy where a thorough engineering analysis inform...
NASA Technical Reports Server (NTRS)
Crannell, C. J.; Crannell, H.; Ramaty, R.
1978-01-01
Processes which lead to the production of gamma rays with energy greater than 8 MeV in solar flares are reviewed and evaluated. Excited states produced by inelastic scattering, charge exchange, and spallation reactions in the abundant nuclear species are considered in order to identify nuclear lines which may contribute to the Gamma ray spectrum of solar flares. The flux of 15.11 MeV Gamma rays relative to the flux of 4.44 MeV Gamma rays from the de-excitation of the corresponding states in C12 is calculated for a number of assumed distributions of exciting particles. This flux ratio is a sensitive diagnostic of accelerated particle spectra. Other high energy nuclear levels are not so isolated as the 15.11 MeV state and are not expected to be so strong. The spectrum of Gamma rays from the decay of Pi dey is sensitive to the energy distribution of particles accelerated to energies greater than 100 MeV.