Science.gov

Sample records for micro amp beam currents

  1. LANSCE beam current limiter

    SciTech Connect

    Gallegos, F.R.

    1996-06-01

    The Radiation Security System (RSS) at the Los Alamos Neutron Science Center (LANSCE) provides personnel protection from prompt radiation due to accelerated beam. Active instrumentation, such as the Beam Current Limiter, is a component of the RSS. The current limiter is designed to limit the average current in a beam line below a specific level, thus minimizing the maximum current available for a beam spill accident. The beam current limiter is a self-contained, electrically isolated toroidal beam transformer which continuously monitors beam current. It is designed as fail-safe instrumentation. The design philosophy, hardware design, operation, and limitations of the device are described.

  2. LANSCE beam current limiter

    SciTech Connect

    Gallegos, F.R.

    1997-01-01

    The Radiation Security System (RSS) at the Los Alamos Neutron Science Center (LANSCE) provides personnel protection from prompt radiation due to accelerated beam. Active instrumentation, such as the beam current limiter, is a component of the RSS. The current limiter is designed to limit the average current in a beamline below a specific level, thus minimizing the maximum current available for a beam spill accident. The beam current limiter is a self-contained, electrically isolated toroidal beam transformer which continuously monitors beam current. It is designed as fail-safe instrumentation. The design philosophy, hardware design, operation, and limitations of the device are described. {copyright} {ital 1997 American Institute of Physics.}

  3. cAMP analogs and their metabolites enhance TREK-1 mRNA and K+ current expression in adrenocortical cells.

    PubMed

    Enyeart, Judith A; Liu, Haiyan; Enyeart, John J

    2010-03-01

    bTREK-1 K(+) channels set the resting membrane potential of bovine adrenal zona fasciculata (AZF) cells and function pivotally in the physiology of cortisol secretion. Adrenocorticotropic hormone controls the function and expression of bTREK-1 channels through signaling mechanisms that may involve cAMP and downstream effectors including protein kinase A (PKA) and exchange protein 2 directly activated by cAMP (Epac2). Using patch-clamp and Northern blot analysis, we explored the regulation of bTREK-1 mRNA and K(+) current expression by cAMP analogs and several of their putative metabolites in bovine AZF cells. At concentrations sufficient to activate both PKA and Epac2, 8-bromoadenosine-cAMP enhanced the expression of both bTREK-1 mRNA and K(+) current. N(6)-Benzoyladenosine-cAMP, which activates PKA but not Epac, also enhanced the expression of bTREK-1 mRNA and K(+) current measured at times from 24 to 96 h. An Epac-selective cAMP analog, 8-(4-chlorophenylthio)-2'-O-methyl-cAMP (8CPT-2'-OMe-cAMP), potently stimulated bTREK-1 mRNA and K(+) current expression, whereas the nonhydrolyzable Epac activator 8-(4-chlorophenylthio)-2'-O-methyl-cAMP, Sp-isomer was ineffective. Metabolites of 8CPT-2'-OMe-cAMP, including 8-(4-chlorophenylthio)-2'-O-methyladenosine-5'-O-monophosphate and 8CPT-2'-OMe-adenosine, promoted the expression of bTREK-1 transcripts and ion current with a temporal pattern, potency, and effectiveness resembling that of the parent compound. Likewise, at low concentrations, 8-(4-chlorophenylthio)-cAMP (8CPT-cAMP; 30 microM) but not its nonhydrolyzable analog 8-(4-chlorophenylthio)-cAMP, Sp-isomer, enhanced the expression of bTREK-1 mRNA and current. 8CPT-cAMP metabolites, including 8CPT-adenosine and 8CPT-adenine, also increased bTREK-1 expression. These results indicate that cAMP increases the expression of bTREK-1 mRNA and K(+) current through a cAMP-dependent but Epac2-independent mechanism. They further demonstrate that one or more metabolites of 8

  4. Beam current sensor

    DOEpatents

    Kuchnir, M.; Mills, F.E.

    1984-09-28

    A current sensor for measuring the dc component of a beam of charged particles employs a superconducting pick-up loop probe, with twisted superconducting leads in combination with a Superconducting Quantum Interference Device (SQUID) detector. The pick-up probe is in the form of a single-turn loop, or a cylindrical toroid, through which the beam is directed and within which a first magnetic flux is excluded by the Meisner effect. The SQUID detector acts as a flux-to-voltage converter in providing a current to the pick-up loop so as to establish a second magnetic flux within the electrode which nulls out the first magnetic flux. A feedback voltage within the SQUID detector represents the beam current of the particles which transit the pick-up loop. Meisner effect currents prevent changes in the magnetic field within the toroidal pick-up loop and produce a current signal independent of the beam's cross-section and its position within the toroid, while the combination of superconducting elements provides current measurement sensitivities in the nano-ampere range.

  5. Beam current sensor

    DOEpatents

    Kuchnir, Moyses; Mills, Frederick E.

    1987-01-01

    A current sensor for measuring the DC component of a beam of charged particles employs a superconducting pick-up loop probe, with twisted superconducting leads in combination with a Superconducting Quantum Interference Device (SQUID) detector. The pick-up probe is in the form of a single-turn loop, or a cylindrical toroid, through which the beam is directed and within which a first magnetic flux is excluded by the Meisner effect. The SQUID detector acts as a flux-to-voltage converter in providing a current to the pick-up loop so as to establish a second magnetic flux within the electrode which nulls out the first magnetic flux. A feedback voltage within the SQUID detector represents the beam current of the particles which transit the pick-up loop. Meisner effect currents prevent changes in the magnetic field within the toroidal pick-up loop and produce a current signal independent of the beam's cross-section and its position within the toroid, while the combination of superconducting elements provides current measurement sensitivites in the nano-ampere range.

  6. LANSCE Beam Current Limiter (XL)

    SciTech Connect

    Gallegos, F.R.; Hall, M.J.

    1997-01-01

    The Radiation Security System (RSS) at the Los Alamos Neutron Science Center (LANSCE) is an engineered safety system that provides personnel protection from prompt radiation due to accelerated proton beams. The Beam Current Limiter (XL), as an active component of the RSS, limits the maximum average current in a beamline, thus the current available for a beam spill accident. Exceeding the pre-set limit initiates action by the RSS to mitigate the hazard (insertion of beam stoppers in the low energy beam transport). The beam limiter is an electrically isolated, toroidal transformer and associated electronics. The device was designed to continuously monitor beamline currents independent of any external timing. Fail-safe operation was a prime consideration in its development. Fail-safe operation is defined as functioning as intended (due to redundant circuitry), functioning with a more sensitive fault threshold, or generating a fault condition. This report describes the design philosophy, hardware, implementation, operation, and limitations of the device.

  7. Tractor beam in micro-scale

    NASA Astrophysics Data System (ADS)

    Brzobohatý, O.; Karásek, V.; Šiler, M.; Chvátal, L.; Čižmár, T.; Zemánek, P.

    2014-12-01

    Following the Keplerian idea of radiative forces one would intuitively expect that an object illuminated by sunlight radiation or a laser beam is accelerated along the direction of the photon flow. Such radiation pressure forms the basis for the concept of solar sail, or laser acceleration of micro-particles. In contrast, a hypothetical optical field known from the realm of science-fiction as the "tractor" beam attracts the matter from large distances against the beam propagation. We present a geometry of such"tractor" beam in micro-scale and experimentally demonstrate how it acts upon spherical micro-particles of various sizes or optically self-arranged structures of micro-particles.

  8. LEDA beam diagnostics instrumentation: Beam current measurement

    NASA Astrophysics Data System (ADS)

    Barr, D.; Day, L.; Gilpatrick, J. D.; Kasemir, K.-U.; Martinez, D.; Power, J. F.; Shurter, R.; Stettler, M.

    2000-11-01

    The Low Energy Demonstration Accelerator (LEDA) facility located at Los Alamos National Laboratory (LANL) accelerates protons to an energy of 6.7 MeV and current of 100 mA operating in either a pulsed or cw mode. Two types of current measurements are used. The first is an AC or pulsed-current measurement which uses three LANL built toroids. They are placed in the beamline in such a way as to measure important transmission parameters and act as a differential current-loss machine protection system. The second system is a DC current measurement used to measure cw beam characteristics and uses toroids from Bergoz Inc. There are two of these systems, so they can also be used for transmission measurements. The AC system uses custom processing electronics whereas the DC system uses a modified Bergoz® electronics system. Both systems feature data acquisition via a series of custom TMS320C40 Digital Signal Processing (DSP) boards. Of special interest to this paper is the operation of these systems, the calibration technique, the differential current loss measurements and fast-protection processing, current droop characteristics for the AC system, and existing system noise levels. This paper will also cover the DSP system operations and their interaction with the main accelerator control system.

  9. Outward currents in Drosophila larval neurons: dunce lacks a maintained outward current component downregulated by cAMP.

    PubMed

    Delgado, R; Davis, R; Bono, M R; Latorre, R; Labarca, P

    1998-02-15

    Outward current modulation by cAMP was investigated in wild type (wt) and dunce (dnc) Drosophila larval neurons. dnc is deficient in a cAMP phosphodiesterase and has altered memory. Outward current modulation by cAMP was investigated by acute or chronic exposure to cAMP analogs. The analysis included a scrutiny of outward current modulation by cAMP in neurons from the mushroom bodies (mrb). In Drosophila, the mrb are the centers of olfactory acquisition and retention. Based on outward current patterns, neurons were classified into four types. Downmodulation of outward currents induced by acute application of cAMP analogs was reversible and found only in type I and type IV neurons. In the general wt neuron population, approximately half of neurons exhibited cAMP-modulated, 4-aminopyridine (4-AP)-sensitive currents. On the other hand, a significantly larger fraction of mrb neurons in wt (70%) was endowed with cAMP-modulated, 4-AP-sensitive currents. Only 30% of the dnc neurons displayed outward currents modulated by cAMP. The deficit of cAMP-modulated outward currents was most severe in neurons derived from the mrb of dnc individuals. Only 4% of the mrb neurons of dnc were cAMP-modulated. The dnc defect can be induced by chronic exposure of wt neurons to cAMP analogs. These results document for the first time a well defined electrophysiological neuron phenotype in correlation with the dnc defect. Moreover, this study demonstrates that in dnc mutants such a deficiency affects most severely neurons in brain centers of acquisition and retention.

  10. Nondestructive synchronous beam current monitor

    SciTech Connect

    Covo, Michel Kireeff

    2014-12-15

    A fast current transformer is mounted after the deflectors of the Berkeley 88-Inch Cyclotron. The measured signal is amplified and connected to the input of a lock-in amplifier. The lock-in amplifier performs a synchronous detection of the signal at the cyclotron second harmonic frequency. The magnitude of the signal detected is calibrated against a Faraday cup and corresponds to the beam intensity. It has exceptional resolution, long term stability, and can measure the beam current leaving the cyclotron as low as 1 nA.

  11. Diagnostic system for profiling micro-beams

    DOEpatents

    Elmer, John W.; Palmer, Todd A.; Teruya, Alan T.; Walton, Chris C.

    2007-10-30

    An apparatus for characterization of a micro beam comprising a micro modified Faraday cup assembly including a first layer of material, a second layer of material operatively connected to the first layer of material, a third layer of material operatively connected to the second layer of material, and a fourth layer of material operatively connected to the third layer of material. The first layer of material comprises an electrical conducting material and has at least one first layer radial slit extending through the first layer. An electrical ground is connected to the first layer. The second layer of material comprises an insulating material and has at least one second layer radial slit corresponding to the first layer radial slit in the first layer of material. The second layer radial slit extends through the second layer. The third layer of material comprises a conducting material and has at least one third layer radial slit corresponding to the second layer radial slit in the second layer of material. The third layer radial slit extends through the third layer. The fourth layer of material comprises an electrical conducting material but does not have slits. An electrical measuring device is connected to the fourth layer. The micro modified Faraday cup assembly is positioned to be swept by the micro beam.

  12. Micro-strip metal detector for the beam profile monitoring

    NASA Astrophysics Data System (ADS)

    Pugatch, V.; Borysova, M.; Mykhailenko, A.; Fedorovitch, O.; Pylypchenko, Y.; Perevertaylo, V.; Franz, H.; Wittenburg, K.; Schmelling, M.; Bauer, C.

    2007-10-01

    The Micro-strip Metal Detector (MMD) design and production technology, readout electronics as well as areas of applications are described. The MMD was designed for beam profile monitoring of charged particle and synchrotron radiation beams. Using photolithography and plasma-chemistry etching technologies we succeeded in creating detectors with a metal strip's thickness of less than 2 μm and without any other materials in the working area. The principle of operation is based on the Secondary Electron Emission (SEE). The results obtained with the MMD at the monochromatic synchrotron radiation beam at HASYLAB (DESY) are also presented. The current version of the MMD allows measuring a beam profile and position with an accuracy of 20 μm.

  13. Knudsen torque on heated micro beams

    SciTech Connect

    Li, Qi; Liang, Tengfei; Ye, Wenjing

    2014-12-09

    Thermally induced mechanical loading has been shown to have significant effects on micro/nano objects immersed in a gas with a non-uniform temperature field. While the majority of existing studies and related applications focus on forces, we investigate the torque, and thus the rotational motion, produced by such a mechanism. Using the asymptotic analysis in the near continuum regime, the Knudsen torque acting on an asymmetrically located uniformly heated microbeam in a cold enclosure is investigated. The existence of a non-zero net torque is demonstrated. In addition, it has been found that by manipulating the system configuration, the rotational direction of the torque can be changed. Two types of rotational motion of the microbeam have been identified: the pendulum motion of a rectangular beam, and the unidirectional rotation of a cylindrical beam. A rotational frequency of 4 rpm can be achieved for the cylindrical beam with a diameter of 3μm at Kn = 0.005. Illustrated by the simulations using the direct simulation of Monte Carlo, the Knudsen torque can be much increased in the transition regime, demonstrating the potential of Knudsen torque serving as a rotation engine for micro/nano objects.

  14. Forskolin's effect on transient K current in nudibranch neurons is not reproduced by cAMP.

    PubMed

    Coombs, J; Thompson, S

    1987-02-01

    Forskolin, a diterpene extracted from Coleus forskolii, stimulates the production of cAMP in a variety of cells and is potentially an important tool for studying the role of cAMP in the modulation of neuronal excitability. We studied the effects of forskolin on neurons of nudibranch molluscs and found that it caused characteristic, reversible changes in the amplitude and waveform of the transient K current, IA, and also activated an inward current similar to the cAMP-dependent inward current previously described in molluscan neurons. Forskolin altered the time course of IA activation and inactivation but did not affect the voltage dependence or the reversal potential of the current. IA normally inactivates exponentially, but in forskolin the time course of inactivation can be fit by the sum of 2 exponentials with an initial rate that is faster than the control and a final rate that is much slower. On depolarization in forskolin, IA begins to activate at the normal rate, but a slower component of activation is also seen. The changes in IA in the nudibranch cells were qualitatively different than the changes caused by forskolin in Aplysia bag cell neurons (Strong, 1984). Experiments were performed to determine whether these effects of forskolin require cAMP. Intracellular injection of cAMP, application of membrane-permeable analogs of cAMP, application of phosphodiesterase inhibitors, and intracellular injection of the active catalytic subunit of cAMP-dependent protein kinase did not affect the amplitude or waveform of IA. Also, the changes in IA that are caused by forskolin were not prevented or reversed by intracellular injection of an inhibitor of cAMP-dependent protein kinase. Cyclic AMP did, however, activate inward current at voltages near the resting potential. We conclude that the changes in IA and the activation of inward current represent separate affects of forskolin. The inward current appears to depend on an increase in intracellular cAMP, while the

  15. High current beam transport with multiple beam arrays

    SciTech Connect

    Kim, C.H.

    1985-05-01

    Highlights of recent experimental and theoretical research progress on the high current beam transport of single and multiple beams by the Heavy Ion Fusion Accelerator Research (HIFAR) group at the Lawrence Berkeley Laboratory (LBL) are presented. In the single beam transport experiment (SBTE), stability boundaries and the emittance growth of a space charge dominated beam in a long quadrupole transport channel were measured and compared with theory and computer simulations. Also, a multiple beam ion induction linac (MBE-4) is being constructed at LBL which will permit study of multiple beam transport arrays, and acceleration and bunch length compression of individually focused beamlets. Various design considerations of MBE-4 regarding scaling laws, nonlinear effects, misalignments, and transverse and longitudinal space charge effects are summarized. Some aspects of longitudinal beam dynamics including schemes to generate the accelerating voltage waveforms and to amplify beam current are also discussed.

  16. Double freeform surfaces design for laser beam shaping with Monge-Ampère equation method

    NASA Astrophysics Data System (ADS)

    Zhang, Yaqin; Wu, Rengmao; Liu, Peng; Zheng, Zhenrong; Li, Haifeng; Liu, Xu

    2014-11-01

    This paper presents a method for designing double freeform surfaces to simultaneously control the intensity distribution and phase profile of the laser beam. Based on Snell’s law, the conservation law of energy and the constraint imposed on the optical path length between the input and output wavefronts, the double surfaces design is converted into an elliptic Monge-Ampère (MA) equation with a nonlinear boundary problem. A generalized approach is introduced to find the numerical solution of the design model. Two different layouts of the beam shaping system are introduced and detailed comparisons are also made between the two layouts. Design examples are given and the results indicate that good matching is achieved by the MA method with more than 98% of the energy efficiency. The MA method proposed in this paper provides a reasonably good means for laser beam shaping.

  17. Precision Absolute Beam Current Measurement of Low Power Electron Beam

    SciTech Connect

    Ali, M. M.; Bevins, M. E.; Degtiarenko, P.; Freyberger, A.; Krafft, G. A.

    2012-11-01

    Precise measurements of low power CW electron beam current for the Jefferson Lab Nuclear Physics program have been performed using a Tungsten calorimeter. This paper describes the rationale for the choice of the calorimeter technique, as well as the design and calibration of the device. The calorimeter is in use presently to provide a 1% absolute current measurement of CW electron beam with 50 to 500 nA of average beam current and 1-3 GeV beam energy. Results from these recent measurements will also be presented.

  18. cAMP-activated chloride currents in amphibian retinal pigment epithelial cells.

    PubMed Central

    Hughes, B A; Segawa, Y

    1993-01-01

    1. The effect of cAMP on whole-cell currents in isolated retinal pigment epithelial (RPE) cells of the bullfrog and marine toad was investigated by means of the perforated patch clamp technique. 2. Superfusing cells with either cAMP or forskolin led to the development of a time-independent current that had a linear current-voltage (I-V) relationship. The reversal potential of (Vrev) of the cAMP-activated current was unaffected by the removal of either Na+ or HCO3- from the external and internal solutions or by the addition of extracellular barium, but it was near the Cl- equilibrium potential (ECl) over a wide range of extracellular Cl- concentrations, suggesting the presence of a Cl(-)-selective channel. 3. The anion permeability sequence of the cAMP-activated conductance calculated from biionic reversal potentials was NO3- = I- > Br- > Cl- >> HCO3- > methanesulphonate. 4. The conductance was blocked by a variety of Cl- transport inhibitors, including 4,4'-diisothiocyanatostilbene-2,2'-disulphonic acid (DIDS), 4,4'-dinitro-2,2'- stilbene disulphonic acid (DNDS), frusemide, N-phenylanthranilic acid (DPC) and niflumic acid. 5. The present study demonstrates that cAMP activates a Cl(-)-selective channel that most probably resides in the basolateral membrane. PMID:8410715

  19. In-line beam current monitor

    DOEpatents

    Ekdahl, Jr., Carl A.; Frost, Charles A.

    1986-01-01

    An intense relativistic electron beam current monitor for a gas neutralized beam transport line includes a first foil for conducting plasma current to the wall where it is measured as it traverses an inductive loop formed by a cavity in the wall. An insulator foil separates the first foil from a second conducting foil which returns the current to the plasma environment.

  20. In-line beam current monitor

    DOEpatents

    Ekdahl, C.A. Jr.; Frost, C.A.

    1984-11-13

    An intense relativistic electron beam current monitor for a gas neutralized beam transport line includes a first foil for conducting plasma current to the wall where it is measured as it traverses an inductive loop formed by a cavity in the wall. An insulator foil separates the first foil from a second conducting foil which returns the current to the plasma environment.

  1. Cyclic AMP enhances calcium-dependent potassium current in Aplysia neurons.

    PubMed

    Ewald, D; Eckert, R

    1983-12-01

    The effect on the Ca-dependent potassium current, IK(Ca), of procedures that increase intracellular cAMP levels was studied in Aplysia neurons using three different pharmacological approaches. Exposure to cAMP analogues which were either resistant to or protected from phosphodiesterase hydrolysis caused an increase in IK(Ca) from 30 to 50% in 10 min. The degree of reversibility of this effect varied from complete with db cAMP to very little with pcpt cAMP. Exposure to cholera toxin, which stimulates the synthesis of endogenous cAMP, increased IK(Ca) 25% in 10 min and the effect was not reversible. Both approaches were effective in all seven neuron types studied. Application of serotonin plus phosphodiesterase inhibitor caused an increase in IK(Ca) in neuron R15 but not in the other neuron types. Application of pentylene tetrazole (PTZ) led to a decrease in IK(Ca). It is proposed that elevation of cyclic AMP mediates an increased sensitivity of the IK(Ca) channel to Ca ions.

  2. Neutral-beam current drive in tokamaks

    SciTech Connect

    Devoto, R.S.

    1986-01-01

    The theory of neutral-beam current drive in tokamaks is reviewed. Experiments are discussed where neutral beams have been used to drive current directly and also indirectly through neoclassical effects. Application of the theory to an experimental test reactor is described. It is shown that neutral beams formed from negative ions accelerated to 500 to 700 keV are needed for this device.

  3. Large bandwidth op-amp based white noise current source

    NASA Astrophysics Data System (ADS)

    Giusi, Gino; Scandurra, Graziella; Ciofi, Carmine

    2014-02-01

    Electrical noise sources are basic building blocks in many measurement and instrumentation applications and in communication systems. In this paper, we propose a quite simple topology for the realization of a programmable, wide bandwidth, white noise current source that requires only two resistors and one operational amplifier. We validate the proposed approach by means of SPICE simulations and demonstrate, by means of proper measurements, the capability of generating a flat current noise spectrum in a frequency range up to four decades from a few Hz up to 100 kHz.

  4. Simultaneous control on the intensity and phase profile of laser beam with Monge-Ampère equation method

    NASA Astrophysics Data System (ADS)

    Zhang, Yaqin; Wu, Rengmao; Zheng, Zhenrong; Li, Haifeng; Liu, Xu

    2014-12-01

    Laser beam shaping requires controlling the intensity and phase profile of the input laser beam simultaneously. In this paper, a method for designing double freeform surfaces is presented to solve the laser beam shaping problem. Based on Snell's law and conservation law of energy, a mathematical model is established to convert the double surfaces design problem into an elliptic Monge-Ampère equation with a nonlinear boundary problem by imposing a constraint on the optical path length between the input and output wavefronts. Two different configurations of the beam shaping system are discussed and the good results show clearly the Monge-Ampère equation method provides an effective tool in solving the challenging problem of laser beam shaping.

  5. Fabrication of micro DOE using micro tools shaped with focused ion beam.

    PubMed

    Xu, Z W; Fang, F Z; Zhang, S J; Zhang, X D; Hu, X T; Fu, Y Q; Li, L

    2010-04-12

    A novel method is proposed to fabricate micro Diffractive Optical Elements (DOE) using micro cutting tools shaped with focused ion beam (FIB) milling. Micro tools with nanometric cutting edges and complicated shapes are fabricated by controlling the tool facet's orientation relative to the FIB. The tool edge radius of less than 30 nm is achieved for the nano removal of the work materials. Semi-circular micro tools and DOE-shaped micro tools are developed to fabricate micro-DOE and sinusoidal modulation templates. Experiments show that the proposed method can be a high efficient way in fabricating micro-DOE with nanoscale surface finishes.

  6. Micro-beam friction liner and method of transferring energy

    DOEpatents

    Mentesana, Charles

    2007-07-17

    A micro-beam friction liner adapted to increase performance and efficiency and reduce wear in a piezoelectric motor or actuator or other device using a traveling or standing wave to transfer energy in the form of torque and momentum. The micro-beam friction liner comprises a dense array of micro-beam projections having first ends fixed relative to a rotor and second ends projecting substantially toward a plurality of teeth of a stator, wherein the micro-beam projections are compressed and bent during piezoelectric movement of the stator teeth, thereby storing the energy, and then react against the stator teeth to convert the stored energy stored to rotational energy in the rotor.

  7. INNOVATIVE EDDY CURRENT PROBE FOR MICRO DEFECTS

    SciTech Connect

    Santos, Telmo G.; Vilaca, Pedro; Quintino, Luisa; Santos, Jorge dos; Rosado, Luis

    2010-02-22

    This paper reports the development of an innovative eddy current (EC) probe, and its application to micro-defects on the root of the Friction Stir Welding (FSW). The new EC probe presents innovative concept issues, allowing 3D induced current in the material, and a lift-off independence. Validation experiments were performed on aluminium alloys processed by FSW. The results clearly show that the new EC probe is able to detect and sizing surface defects about 60 microns depth.

  8. Laser Beam MicroMachining (LBMM) - A review

    NASA Astrophysics Data System (ADS)

    Mishra, Sanjay; Yadava, Vinod

    2015-10-01

    The use of short and ultrashort laser pulses for micromachining application is an emerging technology. Laser Beam MicroMachining (LBMM) has revolutionized many industries by providing innovative solutions in numerous industrial micro-engineering applications. High-intensity short or ultrashort laser pulses are powerful thermal energy source for creating micro-features in wide range of materials. These lasers can precisely ablate various types of materials with little or no collateral damage. An overview of LBMM is given so that we can obtain a current view of capabilities and tradeoffs associated with LBMM of sub-micron size. The fundamental understanding of ultrafast laser ablation process has been elucidated and the various research activities performed with nanosecond, picosecond and femtosecond, lasers have been discussed to understand the physical mechanisms and the critical experimental parameters involved in the LBMM. The critical analysis of various theoretical and experimental models used to describe the performance analysis of LBMM has been elaborated so that we can identify the relevant principles underlying the process.

  9. Polarized electron beams at milliampere average current

    SciTech Connect

    Poelker, Matthew

    2013-11-01

    This contribution describes some of the challenges associated with developing a polarized electron source capable of uninterrupted days-long operation at milliAmpere average beam current with polarization greater than 80%. Challenges will be presented in the context of assessing the required level of extrapolation beyond the performance of today's CEBAF polarized source operating at ~ 200 uA average current. Estimates of performance at higher current will be based on hours-long demonstrations at 1 and 4 mA. Particular attention will be paid to beam-related lifetime-limiting mechanisms, and strategies to construct a photogun that operate reliably at bias voltage > 350kV.

  10. Miniature modified Faraday cup for micro electron beams

    DOEpatents

    Teruya, Alan T.; Elmer, John W.; Palmer, Todd A.; Walton, Chris C.

    2008-05-27

    A micro beam Faraday cup assembly includes a refractory metal layer with an odd number of thin, radially positioned traces in this refractory metal layer. Some of the radially positioned traces are located at the edge of the micro modified Faraday cup body and some of the radially positioned traces are located in the central portion of the micro modified Faraday cup body. Each set of traces is connected to a separate data acquisition channel to form multiple independent diagnostic networks. The data obtained from the two diagnostic networks are combined and inputted into a computed tomography algorithm to reconstruct the beam shape, size, and power density distribution.

  11. Fabrication of phosphor micro-grids using proton beam lithography

    NASA Astrophysics Data System (ADS)

    Auzelyte, V.; Elfman, M.; Kristiansson, P.; Pallon, J.; Wegdén, M.; Nilsson, C.; Malmqvist, K.; Doyle, B. L.; Rossi, P.; Hearne, S. J.; Provencio, P. P.; Antolak, A. J.

    2006-01-01

    A new nuclear microscopy technique called ion photon emission microscopy or IPEM was recently invented. IPEM allows analysis involving single ions, such as ion beam induced charge (IBIC) or single event upset (SEU) imaging using a slightly modified optical microscope. The spatial resolution of IPEM is currently limited to more than 10 μm by the scattering and reflection of ion-induced photons, i.e. light blooming or spreading, in the ionoluminescent phosphor layer. We are developing a "Microscopic Gridded Phosphor" (also called Black Matrix) where the phosphor nanocrystals are confined within the gaps of a micrometer scale opaque grid, which limits the amount of detrimental light blooming. MeV-energy proton beam lithography is ideally suited to lithographically form masks for the grid because of high aspect ratio, pattern density and sub-micron resolution of this technique. In brief, the fabrication of the grids was made in the following manner: (1) a MeV proton beam focused to 1.5-2 μm directly fabricated a matrix of pillars in a 15 μm thick SU-8 lithographic resist; (2) 7:1 aspect ratio pillars were then formed by developing the proton exposed area; (3) Ni (Au) was electrochemically deposited onto Cu-coated Si from a sulfamate bath (or buffered CN bath); (4) the SU-8 pillars were removed by chemical etching; finally (5) the metal micro-grid was freed from its substrate by etching the underlying Cu layer. Our proposed metal micro-grids promise an order-of-magnitude improvement in the resolution of IPEM.

  12. Neutron micro-beam design simulation by Monte Carlo

    NASA Astrophysics Data System (ADS)

    Pazirandeh, Ali; Taheri, Ali

    2007-09-01

    Over the last two decades neutron micro-beam has increasingly been developing in view of various applications in molecular activation analysis, micro-radiography in space and aviation and in radiation induced bystander effects in bio-cells. In this paper the structure and simulation of a neutron micro-beam is presented. The collimator for micro-beam is made of a polyethylene cylinder with a small hole along the centerline of the cylinder. The hole is filled with very thin needles in triangular or rectangular arrangement. The neutron source was reactor neutrons or a spontaneous Cf-252 neutron source falling on the top side of the collimator. The outgoing thermal and epithermal neutron fluxes were calculated.

  13. Achromatic beam transport of High Current Injector

    NASA Astrophysics Data System (ADS)

    Kumar, Sarvesh; Mandal, A.

    2016-02-01

    The high current injector (HCI) provides intense ion beams of high charge state using a high temperature superconducting ECR ion source. The ion beam is accelerated upto a final energy of 1.8 MeV/u due to an electrostatic potential, a radio frequency quadrupole (RFQ) and a drift tube linac (DTL). The ion beam has to be transported to superconducting LINAC which is around 50 m away from DTL. This section is termed as high energy beam transport section (HEBT) and is used to match the beam both in transverse and longitudinal phase space to the entrance of LINAC. The HEBT section is made up of four 90 deg. achromatic bends and interconnecting magnetic quadrupole triplets. Two RF bunchers have been used for longitudinal phase matching to the LINAC. The ion optical design of HEBT section has been simulated using different beam dynamics codes like TRACEWIN, GICOSY and TRACE 3D. The field computation code OPERA 3D has been utilized for hardware design of all the magnets. All the dipole and quadrupole magnets have been field mapped and their test results such as edge angles measurements, homogeneity and harmonic analysis etc. are reported. The whole design of HEBT section has been performed such that the most of the beam optical components share same hardware design and there is ample space for beam diagnostics as per geometry of the building. Many combination of achromatic bends have been simulated to transport the beam in HEBT section but finally the four 90 deg. achromatic bend configuration is found to be the best satisfying all the geometrical constraints with simplified beam tuning process in real time.

  14. Power threshold for neutral beam current drive

    SciTech Connect

    Politzer, P.A. ); Porter, G.D. )

    1989-10-02

    For fully noninductive current drive in tokamaks using neutral beams, there is a power and density threshold condition, setting a minimum value for P{sup 3/2}/n{sup 2}. If this condition is not met, stationary state cannot occur, and a tokamak discharge will collapse. This is a consequence of the coupling between current and electron temperature, or between current drive efficiency and energy confinement time. 4 figs.

  15. Regulation of the beta-stimulation of the Na(+)-K+ pump current in guinea-pig ventricular myocytes by a cAMP-dependent PKA pathway.

    PubMed Central

    Gao, J; Cohen, I S; Mathias, R T; Baldo, G J

    1994-01-01

    1. The whole-cell patch-clamp technique was employed with the free intracellular [Ca2+] fixed at 1.4 microM in order to study the isoprenaline (Iso)-induced increase in the Na(+)-K+ pump current (Ip) in acutely isolated guinea-pig ventricular myocytes. 2. The non-specific protein kinase inhibitor, H-7, eliminated the stimulatory effect of Iso, suggesting a phosphorylation step is involved in the beta-agonist stimulation of Ip. 3. H-7 or the phosphatase inhibitor calyculin A individually had no effect on basal Ip; however, when Ip was first increased by Iso, H-7 inhibited and calyculin A further increased Ip. This suggests phosphorylation is not important to the basal regulation of Ip, but does have an effect during beta-stimulation. 4. The Iso-induced increase in Ip could be mimicked by adding the membrane-permanent cAMP analogue chlorophenylthio-cAMP, blocking cAMP degradation with IBMX or stimulating cAMP production with forskolin. Alternatively the protein kinase A inhibitor PKI blocked the stimulatory effect of Iso. This suggests the Iso-induced phosphorylation responsible for increasing Ip is mediated by cAMP, which then activates protein kinase A (PKA). 5. We conclude that the beta-agonist-induced increase in Ip in the presence of high intracellular [Ca2+] is mediated by a phosphorylation step via the cAMP-dependent PKA pathway. During beta-stimulation, this increase in active Na(+)-K+ transport can serve to offset the effects of increases in passive membrane conductances. PMID:7932227

  16. Indirectly sensing accelerator beam currents for limiting maximum beam current magnitude

    DOEpatents

    Bogaty, J.M.; Clifft, B.E.; Bollinger, L.M.

    1995-08-08

    A beam current limiter is disclosed for sensing and limiting the beam current in a particle accelerator, such as a cyclotron or linear accelerator, used in scientific research and medical treatment. A pair of independently operable capacitive electrodes sense the passage of charged particle bunches to develop an RF signal indicative of the beam current magnitude produced at the output of a bunched beam accelerator. The RF signal produced by each sensing electrode is converted to a variable DC voltage indicative of the beam current magnitude. The variable DC voltages thus developed are compared to each other to verify proper system function and are further compared to known references to detect beam currents in excess of pre-established limits. In the event of a system malfunction, or if the detected beam current exceeds pre-established limits, the beam current limiter automatically inhibits further accelerator operation. A high Q tank circuit associated with each sensing electrode provides a narrow system bandwidth to reduce noise and enhance dynamic range. System linearity is provided by injecting, into each sensing electrode, an RF signal that is offset from the bunching frequency by a pre-determined beat frequency to ensure that subsequent rectifying diodes operate in a linear response region. The system thus provides a large dynamic range in combination with good linearity. 6 figs.

  17. Indirectly sensing accelerator beam currents for limiting maximum beam current magnitude

    DOEpatents

    Bogaty, John M.; Clifft, Benny E.; Bollinger, Lowell M.

    1995-01-01

    A beam current limiter for sensing and limiting the beam current in a particle accelerator, such as a cyclotron or linear accelerator, used in scientific research and medical treatment. A pair of independently operable capacitive electrodes sense the passage of charged particle bunches to develop an RF signal indicative of the beam current magnitude produced at the output of a bunched beam accelerator. The RF signal produced by each sensing electrode is converted to a variable DC voltage indicative of the beam current magnitude. The variable DC voltages thus developed are compared to each other to verify proper system function and are further compared to known references to detect beam currents in excess of pre-established limits. In the event of a system malfunction, or if the detected beam current exceeds pre-established limits, the beam current limiter automatically inhibits further accelerator operation. A high Q tank circuit associated with each sensing electrode provides a narrow system bandwidth to reduce noise and enhance dynamic range. System linearity is provided by injecting, into each sensing electrode, an RF signal that is offset from the bunching frequency by a pre-determined beat frequency to ensure that subsequent rectifying diodes operate in a linear response region. The system thus provides a large dynamic range in combination with good linearity.

  18. Beam-current monitor for FMIT

    SciTech Connect

    Chamberlin, D.D.; Brousseau, A.T.

    1981-03-01

    The application of a single toroidal core, coupled with very simple circuitry, that results in the production of a simple instrument, and eliminates the problems inherent in the Faraday cup technique for the current measurements of the FMIT injector beam is described. (GHT)

  19. Charged particle beam current monitoring tutorial

    SciTech Connect

    Webber, R.C.

    1994-10-01

    A tutorial presentation is made on topics related to the measurement of charged particle beam currents. The fundamental physics of electricity and magnetism pertinent to the problem is reviewed. The physics is presented with a stress on its interpretation from an electrical circuit theory point of view. The operation of devices including video pulse current transformers, direct current transformers, and gigahertz bandwidth wall current style transformers is described. Design examples are given for each of these types of devices. Sensitivity, frequency response, and physical environment are typical parameters which influence the design of these instruments in any particular application. Practical engineering considerations, potential pitfalls, and performance limitations are discussed.

  20. Polarized electron beams at milliampere average current

    SciTech Connect

    Poelker, M.

    2013-11-07

    This contribution describes some of the challenges associated with developing a polarized electron source capable of uninterrupted days-long operation at milliAmpere average beam current with polarization greater than 80%. Challenges will be presented in the context of assessing the required level of extrapolation beyond the performance of today’s CEBAF polarized source operating at ∼ 200 uA average current. Estimates of performance at higher current will be based on hours-long demonstrations at 1 and 4 mA. Particular attention will be paid to beam-related lifetime-limiting mechanisms, and strategies to construct a photogun that operate reliably at bias voltage > 350kV.

  1. Note: A real-time beam current density meter

    SciTech Connect

    Liu Junliang; Yu Deyang; Ruan Fangfang; Xue Yingli; Wang Wei

    2013-03-15

    We have developed a real-time beam current density meter for charged particle beams. It measures the mean current density by collimating a uniform and large diameter primary beam. The suppression of the secondary electrons and the deflection of the beam were simulated, and it was tested with a 105 keV Ar{sup 7+} ion beam.

  2. Maskless micro-ion-beam reduction lithography system

    DOEpatents

    Leung, Ka-Ngo; Barletta, William A.; Patterson, David O.; Gough, Richard A.

    2005-05-03

    A maskless micro-ion-beam reduction lithography system is a system for projecting patterns onto a resist layer on a wafer with feature size down to below 100 nm. The MMRL system operates without a stencil mask. The patterns are generated by switching beamlets on and off from a two electrode blanking system or pattern generator. The pattern generator controllably extracts the beamlet pattern from an ion source and is followed by a beam reduction and acceleration column.

  3. Micro/nanofabrication of poly(L-lactic acid) using focused ion beam direct etching

    NASA Astrophysics Data System (ADS)

    Oyama, Tomoko Gowa; Hinata, Toru; Nagasawa, Naotsugu; Oshima, Akihiro; Washio, Masakazu; Tagawa, Seiichi; Taguchi, Mitsumasa

    2013-10-01

    Micro/nanofabrication of biocompatible and biodegradable poly(L-lactic acid) (PLLA) using focused Ga ion beam direct etching was evaluated for future bio-device applications. The fabrication performance was determined with different ion fluences and fluxes (beam currents), and it was found that the etching speed and fabrication accuracy were affected by irradiation-induced heat. Focused ion beam (FIB)-irradiated surfaces were analyzed using micro-area X-ray photoelectron spectroscopy. Owing to reactions such as the physical sputtering of atoms and radiation-induced decomposition, PLLA was gradually carbonized with increasing C=C bonds. Controlled micro/nanostructures of PLLA were fabricated with C=C bond-rich surfaces expected to have good cell attachment properties.

  4. Ion Micro Beam, promising methods for interdisciplinary research

    NASA Astrophysics Data System (ADS)

    Cutroneo, M.; Havranek, V.; Torrisi, L.; Svecova, B.

    2016-05-01

    An increasing attractiveness of top-down nanotechnology using nuclear microprobe techniques have been gathered to the micro and nano patterning process for polymers. This paper presents the research activity on innovative promising techniques able to produce three- dimensional (3D) micro-structures in polymeric resists as well as to obtain images of fabricated nanostructures at Tandetron Laboratory (LT) of the Nuclear Physics Institute in Rez (Czech Republic). The Proton Beam Writing (PBW) technique was used to irradiate PMMA resist with energy of MeVs protons. The fabricated patterns were developed in chemical bath using different etching rates. An overview of micro-scale structures have been fabricated selecting the beam, the energy, the fluence and the exposition time. The produced structures were investigated by different analysis techniques among which Scanning Transmission Ion Microscopy (STIM). The characterizations of the fabricated microtunnels are presented and discussed.

  5. NRSF causes cAMP-sensitive suppression of sodium current in cultured hippocampal neurons

    NASA Technical Reports Server (NTRS)

    Nadeau, H.; Lester, H. A.

    2002-01-01

    The neuron restrictive silencer factor (NRSF/REST) has been shown to bind to the promoters of many neuron-specific genes and is able to suppress transcription of Na(+) channels in PC12 cells, although its functional effect in terminally differentiated neurons is unknown. We constructed lentiviral vectors to express NRSF as a bicistronic message with green fluorescent protein (GFP) and followed infected hippocampal neurons in culture over a period of 1-2 wk. NRSF-expressing neurons showed a time-dependent suppression of Na(+) channel function as measured by whole cell electrophysiology. Suppression was reversed or prevented by the addition of membrane-permeable cAMP analogues and enhanced by cAMP antagonists but not affected by increasing protein expression with a viral enhancer. Secondary effects, including altered sensitivity to glutamate and GABA and reduced outward K(+) currents, were duplicated by culturing GFP-infected control neurons in TTX. The striking similarity of the phenotypes makes NRSF potentially useful as a genetic "silencer" and also suggests avenues of further exploration that may elucidate the transcription factor's in vivo role in neuronal plasticity.

  6. Ion Beam Sputter Fabrication of Micro-Grooving and Micro-Threading Tools

    SciTech Connect

    ADAMS,DAVID P.; VASILE,M.J.; KRISHNAN,A.S.M.

    1999-11-05

    This paper presents techniques for fabricating microscopic, nonplanar features in a variety of materials. Micro-grooving and micro-threading tools having cutting dimensions of 10-30{micro}m are made by focused ion beam sputtering and used in ultra-precision machining. Tool fabrication involves directing a 20 keV gallium beam at polished cylindrical punches made of cobalt M42 high-speed steel or C2 tungsten carbide. This creates cutting edges having radii of curvature less than 0.4 {micro}m, and rake features similar to conventional lathe tools. Clearance for minimizing frictional drag of a tool results from the sputter yield dependence on ion herd target incidence angle. Numerically controlled, ultra-precision machining with micro-grooving tools results in a close matching between tool width and feature size. Microtools controllably machine 13 {micro}m wide, 4 {micro}m deep, helical grooves in polymethyl methacrylate and 6061-T6 Al cylindrical substrates. Micro-grooving tools also fabricate sinusoidal waveform features in polished metal substrates.

  7. Diagnostic Tools For Low Intensity Ion Micro-Beams

    SciTech Connect

    Finocchiaro, P.; Cosentino, L.; Pappalardo, A.; Vervaeke, M.; Volckaerts, B.; Vynck, P.; Hermanne, A.; Thienpont, H.

    2003-08-26

    We have developed two techniques for microscopic ion beam imaging and profiling, both based on scintillators, particularly suitable for applications in Deep Lithography with Protons (DLP) or with heavier ions. The first one employs a scintillating fiberoptic plate and a CCD camera with suitable lenses, the second makes use of a small scintillator optically coupled to a compact photomultiplier. We have proved the possibility of spanning from single beam particles counting up to several nA currents. Both devices are successfully being exploited for on-line control of low and very low intensity proton beams, down to a beam size of less than 50{mu}m.

  8. Nanosecond laser micro machining using an external beam attenuator

    NASA Astrophysics Data System (ADS)

    Bosman, Johan; Kettelarij, Henk; de Kok, Corne J. G. M.

    2003-11-01

    The pulse width -- pulse energy relationship of a solid-state laser can reduce the accuracy of micro machined features. Our goal is to control a depth of a laser mark with an accuracy of 0.1 μm and reduce the line width below the spot diameter. Reaching this depth and width in a stable and industrial viable laser process would not have been possible without the additional control generated by the beam attenuator.

  9. Optical transition radiation used in the diagnostic of low energy and low current electron beams in particle accelerators

    NASA Astrophysics Data System (ADS)

    Silva, T. F.; Bonini, A. L.; Lima, R. R.; Maidana, N. L.; Malafronte, A. A.; Pascholati, P. R.; Vanin, V. R.; Martins, M. N.

    2012-09-01

    Optical transition radiation (OTR) plays an important role in beam diagnostics for high energy particle accelerators. Its linear intensity with beam current is a great advantage as compared to fluorescent screens, which are subject to saturation. Moreover, the measurement of the angular distribution of the emitted radiation enables the determination of many beam parameters in a single observation point. However, few works deals with the application of OTR to monitor low energy beams. In this work we describe the design of an OTR based beam monitor used to measure the transverse beam charge distribution of the 1.9-MeV electron beam of the linac injector of the IFUSP microtron using a standard vision machine camera. The average beam current in pulsed operation mode is of the order of tens of nano-Amps. Low energy and low beam current make OTR observation difficult. To improve sensitivity, the beam incidence angle on the target was chosen to maximize the photon flux in the camera field-of-view. Measurements that assess OTR observation (linearity with beam current, polarization, and spectrum shape) are presented, as well as a typical 1.9-MeV electron beam charge distribution obtained from OTR. Some aspects of emittance measurement using this device are also discussed.

  10. Optical transition radiation used in the diagnostic of low energy and low current electron beams in particle accelerators.

    PubMed

    Silva, T F; Bonini, A L; Lima, R R; Maidana, N L; Malafronte, A A; Pascholati, P R; Vanin, V R; Martins, M N

    2012-09-01

    Optical transition radiation (OTR) plays an important role in beam diagnostics for high energy particle accelerators. Its linear intensity with beam current is a great advantage as compared to fluorescent screens, which are subject to saturation. Moreover, the measurement of the angular distribution of the emitted radiation enables the determination of many beam parameters in a single observation point. However, few works deals with the application of OTR to monitor low energy beams. In this work we describe the design of an OTR based beam monitor used to measure the transverse beam charge distribution of the 1.9-MeV electron beam of the linac injector of the IFUSP microtron using a standard vision machine camera. The average beam current in pulsed operation mode is of the order of tens of nano-Amps. Low energy and low beam current make OTR observation difficult. To improve sensitivity, the beam incidence angle on the target was chosen to maximize the photon flux in the camera field-of-view. Measurements that assess OTR observation (linearity with beam current, polarization, and spectrum shape) are presented, as well as a typical 1.9-MeV electron beam charge distribution obtained from OTR. Some aspects of emittance measurement using this device are also discussed.

  11. Differential control of the hyperpolarization-activated current (i(f)) by cAMP gating and phosphatase inhibition in rabbit sino-atrial node myocytes.

    PubMed Central

    Accili, E A; Redaelli, G; DiFrancesco, D

    1997-01-01

    1. The actions of the phosphatase inhibitor calyculin A on the hyperpolarization-activated cardiac 'pacemaker' current (i(f)) were determined in single cells isolated from the sino-atrial (SA) node of the rabbit. 2. Cells were incubated for 8 min in Tyrode solution containing calyculin A (0.5 microM) and then superfused with normal Tyrode solution. The mean normalized i(f) measured in eight cells at mid-activation voltages during and after exposure to calyculin A increased maximally by 47% with a time constant of 466 s, a time much longer than that required for cAMP-mediated i(f) stimulation (about 8 s). 3. In two-pulse protocols, calyculin A treatment increased i(f) at full as well as at mid-activation voltages, indicating a higher i(f) conductance. 4. Measurement of the conductance-voltage (gf(V)) relation by voltage ramp protocols confirmed a conductance increase by calyculin A, with no significant change in the position of the activation curve on the voltage axis. Data pooled together from ramp and two-pulse protocols yielded a calyculin A-induced increase in fully activated i(f) conductance of 39.6 +/- 6.4% (n = 16 cells). 5. The positive and negative shift of i(f) voltage dependence in response to beta-adrenergic (1 microM isoprenaline) and muscarinic stimulation (1 microM acetylcholine), respectively, was preserved after the calyculin A-induced increase in conductance. The shift of the i(f) activation curve induced by 1 microM isoprenaline was significantly larger in calyculin A-treated cells (8.8 vs. 5.8 mV). 6. These data indicate that phosphatase inhibition increases i(f) in a manner distinct from the direct cAMP pathway and potentiates the beta-adrenergic-mediated i(f) modulation. PMID:9161982

  12. Modulation by stimulation rate of basal and cAMP-elevated Ca2+ channel current in guinea pig ventricular cardiomyocytes

    PubMed Central

    1995-01-01

    The modulation of L-type Ca2+ current (ICa) by changes in stimulation frequency was investigated in single ventricular cardiomyocytes isolated from guinea pig hearts. Electrical recordings were carried out at 21-25 degrees C and at 33-37 degrees C with the whole-cell patch clamp method, under K(+)-free conditions. A comparison is made between the response to frequency changes for ICa in the basal state and after the application of drugs which elevate the level of adenosine-3',5'- cyclic monophosphate (cAMP) within the cells. Peak basal ICa was reduced with an increase in stimulation rate from 0.5 Hz to 1, 2, 3, 4, or 5 Hz. This frequency-induced reduction of ICa was enhanced by reduced temperature, was unchanged when Na+ or Ba2+ carried the basal Ca2+ channel current, and was greatly enhanced after elevating cAMP levels with forskolin, isoprenaline, or 8-(4-chlorophenylthio)-cyclic AMP. We examined the mechanism of the enhancement of the frequency- induced reduction of ICa by cAMP, and found two conditions which abolished it: (a) application of isoprenaline when Na+ carried the Ca2+ channel current in Ca(2+)-free solution, or (b) application of 3- isobutyl-1-methylxanthine, a broad-spectrum phosphodiesterase inhibitor. It was further shown that an elevation of both ICa and cAMP (induced by isoprenaline), and not an increase of ICa alone (induced by Bay K 8644), is required to produce the extra component of reduction by frequency. It is concluded that Ca2+ entry results in feedback regulation of ICa, through the activation of Ca(2+)-dependent phosphodiesterase(s). This is important in the context of sympathetic stimulation, which produces the companion conditions of an elevated heart rate and increases in cAMP levels and Ca2+ entry. PMID:8537815

  13. Triggered beam pulser and current integrator for PIXE analysis

    NASA Astrophysics Data System (ADS)

    Birch, D. T.; Skofronick, G.; Nelson, J. W.

    1987-03-01

    Two auxiliary circuits to facilitate PIXE analyses are described: a triggerable beam pulser tor pile-up reduction and dead time correction; and a versatile voltage to frequency converter for use with a beam current integrator.

  14. LogAmp electronics and optical transmission for the new SPS beam position measurement system

    NASA Astrophysics Data System (ADS)

    Bogey, T.; Deplano, C.; Gonzalez, J. L.; Savioz, J. J.

    2013-12-01

    A new front-end board is under development for the CERN SPS Multi ORbit Position System (MOPOS). Based on logarithmic amplifiers, it measures the beam position over a large dynamic range of beam intensities and resolves the multi-batch structure of the SPS beams. Analogue data are digitized at 10 MS/s, packed in frames by an FPGA and on every turn sent to the readout board, via a 2.4 Gb/s optical transmission link. A first prototype has been successfully tested with several SPS beams. This paper presents an overall description of the system and its capabilities highlighted by the first beam measurements.

  15. Solar wind double ions beams and the heliospheric current sheet

    NASA Technical Reports Server (NTRS)

    Hammond, C. M.; Feldman, W. C.; Phillips, J. L.; Goldstein, B. E.; Balogh, A.

    1995-01-01

    Double ion beams are often observed in the solar wind, but little work has been done in relating these beams to structures within the solar wind. Double ion beams are observed as beams of a given ion species and charge state occurring at two different energies. We use the three-dimensional ion plasma instrument on board the Ulysses spacecraft to look for evidence of such beams associated with the heliospheric current sheet. In a subset chosen independently of plasma parameters consisting of 8 of cover 47 crossings of the current sheet made during the inecliptic phase of the Ulysses mission we find that these double ion beams are always present on either side of the current sheet. The double beams are present in both the proton and helium species. The secondary beam typically has a higher helium abundance, which suggests that these beams are formed in the helium-rich corona rather than in interplanetary space. The double beams are not present in the interior of the current sheet. Neither collisions nor effects of plasma beta can account for the disappearance of the double beams inside the current sheet in all eight cases. We postulate that these beams are formed by reconnection occurring near the Sun in the boundary region between the open field lines of the coronal holes and the closed field line region of the heliospheric current sheet. Such a scenario would be consistent with previous X ray measurements which suggect that reconnection is occurring in this region.

  16. Micro/nanofabrication of poly({sub L}-lactic acid) using focused ion beam direct etching

    SciTech Connect

    Oyama, Tomoko Gowa; Nagasawa, Naotsugu; Taguchi, Mitsumasa; Hinata, Toru; Washio, Masakazu; Oshima, Akihiro; Tagawa, Seiichi

    2013-10-14

    Micro/nanofabrication of biocompatible and biodegradable poly({sub L}-lactic acid) (PLLA) using focused Ga ion beam direct etching was evaluated for future bio-device applications. The fabrication performance was determined with different ion fluences and fluxes (beam currents), and it was found that the etching speed and fabrication accuracy were affected by irradiation-induced heat. Focused ion beam (FIB)-irradiated surfaces were analyzed using micro-area X-ray photoelectron spectroscopy. Owing to reactions such as the physical sputtering of atoms and radiation-induced decomposition, PLLA was gradually carbonized with increasing C=C bonds. Controlled micro/nanostructures of PLLA were fabricated with C=C bond-rich surfaces expected to have good cell attachment properties.

  17. MicroRNA-181b targets cAMP responsive element binding protein 1 in gastric adenocarcinomas.

    PubMed

    Chen, Lin; Yang, Qian; Kong, Wei-Qing; Liu, Tao; Liu, Min; Li, Xin; Tang, Hua

    2012-07-01

    MicroRNAs are a class of small endogenous non-coding RNAs that function as post-transcriptional regulators. In our previous study, we found that miR-181b was significantly downregulated in human gastric adenocarcinoma tissue samples compared to the adjacent normal gastric tissues. In this study, we confirm the down-regulation of miR-181b in human gastric cancer cell lines versus the gastric epithelial cells. Overexpression of miR-181b suppressed the proliferation and colony formation rate of gastric cancer cells. miR-181b downregulated the expression of cAMP responsive element binding protein 1 (CREB1) by binding its 3' untranslated region. Overexpression of CREB1 counteracted the suppression of growth in gastric cancer cells caused by ectopic expression of miR-181b. These results indicate that miR-181b may function as a tumor suppressor in gastric adenocarcinoma cells through negative regulation of CREB1.

  18. Modafinil inhibits K(Ca)3.1 currents and muscle contraction via a cAMP-dependent mechanism.

    PubMed

    Choi, Shinkyu; Kim, Moon Young; Joo, Ka Young; Park, Seonghee; Kim, Ji Aee; Jung, Jae-Chul; Oh, Seikwan; Suh, Suk Hyo

    2012-07-01

    Modafinil has been used as a psychostimulant for the treatment of narcolepsy. However, its primary mechanism of action remains elusive. Therefore, we examined the effects of modafinil on K(Ca)3.1 channels and vascular smooth muscle contraction. K(Ca)3.1 currents and channel activity were measured using a voltage-clamp technique and inside-out patches in mouse embryonic fibroblast cell line, NIH-3T3 fibroblasts. Intracellular adenosine 3',5'-cyclic monophosphate (cAMP) concentration was measured, and the phosphorylation of K(Ca)3.1 channel protein was examined using western blotting in NIH-3T3 fibroblasts and/or primary cultured mouse aortic smooth muscle cells (SMCs). Muscle contractions were recorded from mouse aorta and rat pulmonary artery by using a myograph developed in-house. Modafinil was found to inhibit K(Ca)3.1 currents in a concentration-dependent manner, and the half-maximal inhibition (IC(50)) of modafinil for the current inhibition was 6.8 ± 0.7 nM. The protein kinase A (PKA) activator forskolin also inhibited K(Ca)3.1 currents. The inhibitory effects of modafinil and forskolin on K(Ca)3.1 currents were blocked by the PKA inhibitors PKI(14-22) or H-89. In addition, modafinil relaxed blood vessels (mouse aorta and rat pulmonary artery) in a concentration-dependent manner. Modafinil increased cAMP concentrations in NIH-3T3 fibroblasts or primary cultured mouse aortic SMCs and phosphorylated K(Ca)3.1 channel protein in NIH-3T3 fibroblasts. However, open probability and single-channel current amplitudes of K(Ca)3.1 channels were not changed by modafinil. From these results, we conclude that modafinil inhibits K(Ca)3.1 channels and vascular smooth muscle contraction by cAMP-dependent phosphorylation, suggesting that modafinil can be used as a cAMP-dependent K(Ca)3.1 channel blocker and vasodilator.

  19. Limiting current of intense electron beams in a decelerating gap

    NASA Astrophysics Data System (ADS)

    Nusinovich, G. S.; Beaudoin, B. L.; Thompson, C.; Karakkad, J. A.; Antonsen, T. M.

    2016-02-01

    For numerous applications, it is desirable to develop electron beam driven efficient sources of electromagnetic radiation that are capable of producing the required power at beam voltages as low as possible. This trend is limited by space charge effects that cause the reduction of electron kinetic energy and can lead to electron reflection. So far, this effect was analyzed for intense beams propagating in uniform metallic pipes. In the present study, the limiting currents of intense electron beams are analyzed for the case of beam propagation in the tubes with gaps. A general treatment is illustrated by an example evaluating the limiting current in a high-power, tunable 1-10 MHz inductive output tube (IOT), which is currently under development for ionospheric modification. Results of the analytical theory are compared to results of numerical simulations. The results obtained allow one to estimate the interaction efficiency of IOTs.

  20. Drift distance survey in DPIS for high current beam production

    SciTech Connect

    Kanesue,T.; Okamura, M.; Kondo, K.; Tamura, J.; Kashiwagi, H.; Zhang, Z.

    2009-09-20

    In a laser ion source, plasma drift distance is one of the most important design parameters. Ion current density and beam pulse width are defined by plasma drift distance between laser target and beam extraction position. In direct plasma injection scheme (DPIS), which uses a laser ion source and Radio Frequency Quadrupole (RFQ) linac, we can apply relatively higher electric field at the beam extraction due to the unique shape of a positively biased electrode. However, when we aim at very high current acceleration like several tens of mA, we observed mismatched beam extraction conditions. We tested three different ion current at ion extraction region by changing plasma drift distance to study better extraction condition. In this experiment, C{sup 6+} beam was accelerated. We confirmed that the matching condition can be improved by controlling plasma drift distance.

  1. Measurement and Evaluation of the Gas Density and Viscosity of Pure Gases and Mixtures Using a Micro-Cantilever Beam.

    PubMed

    Badarlis, Anastasios; Pfau, Axel; Kalfas, Anestis

    2015-09-22

    Measurement of gas density and viscosity was conducted using a micro-cantilever beam. In parallel, the validity of the proposed modeling approach was evaluated. This study also aimed to widen the database of the gases on which the model development of the micro-cantilever beams is based. The density and viscosity of gases are orders of magnitude lower than liquids. For this reason, the use of a very sensitive sensor is essential. In this study, a micro-cantilever beam from the field of atomic force microscopy was used. Although the current cantilever was designed to work with thermal activation, in the current investigation, it was activated with an electromagnetic force. The deflection of the cantilever beam was detected by an integrated piezo-resistive sensor. Six pure gases and sixteen mixtures of them in ambient conditions were investigated. The outcome of the investigation showed that the current cantilever beam had a sensitivity of 240 Hz/(kg/m³), while the accuracy of the determined gas density and viscosity in ambient conditions reached ±1.5% and ±2.0%, respectively.

  2. Measurement and Evaluation of the Gas Density and Viscosity of Pure Gases and Mixtures Using a Micro-Cantilever Beam

    PubMed Central

    Badarlis, Anastasios; Pfau, Axel; Kalfas, Anestis

    2015-01-01

    Measurement of gas density and viscosity was conducted using a micro-cantilever beam. In parallel, the validity of the proposed modeling approach was evaluated. This study also aimed to widen the database of the gases on which the model development of the micro-cantilever beams is based. The density and viscosity of gases are orders of magnitude lower than liquids. For this reason, the use of a very sensitive sensor is essential. In this study, a micro-cantilever beam from the field of atomic force microscopy was used. Although the current cantilever was designed to work with thermal activation, in the current investigation, it was activated with an electromagnetic force. The deflection of the cantilever beam was detected by an integrated piezo-resistive sensor. Six pure gases and sixteen mixtures of them in ambient conditions were investigated. The outcome of the investigation showed that the current cantilever beam had a sensitivity of 240 Hz/(kg/m3), while the accuracy of the determined gas density and viscosity in ambient conditions reached ±1.5% and ±2.0%, respectively. PMID:26402682

  3. Experimental Investigation of Micro Counter-Current Flow Using High-Speed Micro PIV

    NASA Astrophysics Data System (ADS)

    Shinohara, Kyosuke; Sugii, Yasuhiko; Aota, Arata; Hibara, Akihide; Kitamori, Takehiko; Okamoto, Koji

    2004-11-01

    Microfluidic devices have been developed for chemical analysis as micro total analysis systems (u-TAS). To utilize scale merits, continuous-flow chemical processing and micro unit operations had been proposed as microfluidic device including mixing, phase confluence, solvent extraction, and so on. Recently, as one of these integrated chemical processes, micro counter-current flow system had been developed for highly efficient solvent extraction. The system consisted of oil flow and water flow in inverse direction. Using the system, more efficient extraction of Co (II) complex than theoretical prediction was confirmed. In this paper, in order to investigate the fundamental characteristics of the micro counter-current flow, velocity fields of the micro counter-current flow were measured using high-speed micro PIV system. The system consisted of a high-speed CMOS camera with an image intensifier, an epi-fluorescent microscope with an objective lens and a color filter, and a CW laser. The velocity fields of water were visualized for a time resolution of 500 us and a spatial resolution of 2.2 x 2.2 um. Transient micro vortices at the water-butyl acetate interface were captured clearly.

  4. Low Impedance Bellows for High-current Beam Operations

    SciTech Connect

    Wu, G; Nassiri, A; Waldschmidt, G J; Yang, Y; Feingold, J J; Mammosser, J D; Rimmer, R A; Wang, H; Jang, J; Kim, S H

    2012-07-01

    In particle accelerators, bellows are commonly used to connect beamline components. Such bellows are traditionally shielded to lower the beam impedance. Excessive beam impedance can cause overheating in the bellows, especially in high beam current operation. For an SRF-based accelerator, the bellows must also be particulate free. Many designs of shielded bellows incorporate rf slides or fingers that prevent convolutions from being exposed to wakefields. Unfortunately these mechanical structures tend to generate particulates that, if left in the SRF accelerator, can migrate into superconducting cavities, the accelerator's critical components. In this paper, we describe a prototype unshielded bellows that has low beam impedance and no risk of particulate generation.

  5. Dynamics of a high-current relativistic electron beam

    SciTech Connect

    Strelkov, P. S.; Tarakanov, V. P.; Ivanov, I. E. Shumeiko, D. V.

    2015-06-15

    The dynamics of a high-current relativistic electron beam is studied experimentally and by numerical simulation. The beam is formed in a magnetically insulated diode with a transverse-blade explosive-emission cathode. It is found experimentally that the radius of a 500-keV beam with a current of 2 kA and duration of 500 ns decreases with time during the beam current pulse. The same effect was observed in numerical simulations. This effect is explained by a change in the shape of the cathode plasma during the current pulse, which, according to calculations, leads to a change in the beam parameters, such as the electron pitch angle and the spread over the longitudinal electron momentum. These parameters are hard to measure experimentally; however, the time evolution of the radial profile of the beam current density, which can be measured reliably, coincides with the simulation results. This allows one to expect that the behavior of the other beam parameters also agrees with numerical simulations.

  6. Amending the uniformity of ion beam current density profile

    NASA Astrophysics Data System (ADS)

    Zhou, Xiaowei; Xu, Dequan; Liu, Ying; Xu, Xiangdong; Fu, Shaojun

    2008-03-01

    The uniformity of ion beam current density profile has been amended by changing the flow of the gas and making a new beam channel. The platform scanned in the horizontal orientation in this experiment, so the horizontal ion beam current distribution had hardly any effect on the etching uniformity and amending the ion beam current density profile in the vertical orientation was sufficient for the purpose of plat etching profile. The ratio of the ion source's working gas inputs has some effect for the uniformity and a ratio of 6.50sccm: 8.00sccm: 9.60sccm of the three gas inputs flow1: flow2: flow3 will lead to a more uniform profile. According to the horizontal distribution and the original vertical ion beam current density distribution measured by Faraday Cup, a new beam channel was made. The uniformity of ion beam current density profile is enhanced from +/-4.31%to +/-1.96% in this experiment.

  7. Physics Impact of Improvements to the Beam Timing Resolution at MicroBooNE

    NASA Astrophysics Data System (ADS)

    Miceli, Tia; MicroBooNE Collaboration

    2017-01-01

    The MicroBooNE detector is a liquid argon time-projection chamber (89 tons active mass) at Fermilab designed to measure interactions of neutrinos from the Booster Neutrino Beamline (BNB) and the Neutrinos at the Main Injector (NuMI) beamline. During the first year of data-taking, the arrival time of the neutrinos was only understood with an accuracy of 100 ns for the BNB, and was unverified for NuMI. A set of upgrades has been implemented that will reduce the uncertainty in beam delivery time by two orders of magnitude, significantly improving our ability to observe neutral-current elastic interactions in the BNB, and kaon decays at rest using NuMI. This talk explains the improvements in neutrino arrival timing, their impact on these two analyses, and the overall benefit to all other MicroBooNE measurements. DOE Office of Science.

  8. Polymorphic beams and Nature inspired circuits for optical current

    PubMed Central

    Rodrigo, José A.; Alieva, Tatiana

    2016-01-01

    Laser radiation pressure is a basis of numerous applications in science and technology such as atom cooling, particle manipulation, material processing, etc. This light force for the case of scalar beams is proportional to the intensity-weighted wavevector known as optical current. The ability to design the optical current according to the considered application brings new promising perspectives to exploit the radiation pressure. However, this is a challenging problem because it often requires confinement of the optical current within tight light curves (circuits) and adapting its local value for a particular task. Here, we present a formalism to handle this problem including its experimental demonstration. It consists of a Nature-inspired circuit shaping with independent control of the optical current provided by a new kind of beam referred to as polymorphic beam. This finding is highly relevant to diverse optical technologies and can be easily extended to electron and x-ray coherent beams. PMID:27734940

  9. Polymorphic beams and Nature inspired circuits for optical current

    NASA Astrophysics Data System (ADS)

    Rodrigo, José A.; Alieva, Tatiana

    2016-10-01

    Laser radiation pressure is a basis of numerous applications in science and technology such as atom cooling, particle manipulation, material processing, etc. This light force for the case of scalar beams is proportional to the intensity-weighted wavevector known as optical current. The ability to design the optical current according to the considered application brings new promising perspectives to exploit the radiation pressure. However, this is a challenging problem because it often requires confinement of the optical current within tight light curves (circuits) and adapting its local value for a particular task. Here, we present a formalism to handle this problem including its experimental demonstration. It consists of a Nature-inspired circuit shaping with independent control of the optical current provided by a new kind of beam referred to as polymorphic beam. This finding is highly relevant to diverse optical technologies and can be easily extended to electron and x-ray coherent beams.

  10. Polymorphic beams and Nature inspired circuits for optical current.

    PubMed

    Rodrigo, José A; Alieva, Tatiana

    2016-10-13

    Laser radiation pressure is a basis of numerous applications in science and technology such as atom cooling, particle manipulation, material processing, etc. This light force for the case of scalar beams is proportional to the intensity-weighted wavevector known as optical current. The ability to design the optical current according to the considered application brings new promising perspectives to exploit the radiation pressure. However, this is a challenging problem because it often requires confinement of the optical current within tight light curves (circuits) and adapting its local value for a particular task. Here, we present a formalism to handle this problem including its experimental demonstration. It consists of a Nature-inspired circuit shaping with independent control of the optical current provided by a new kind of beam referred to as polymorphic beam. This finding is highly relevant to diverse optical technologies and can be easily extended to electron and x-ray coherent beams.

  11. Laser beam micro-milling of nickel alloy: dimensional variations and RSM optimization of laser parameters

    NASA Astrophysics Data System (ADS)

    Ahmed, Naveed; Alahmari, Abdulrahman M.; Darwish, Saied; Naveed, Madiha

    2016-12-01

    Micro-channels are considered as the integral part of several engineering devices such as micro-channel heat exchangers, micro-coolers, micro-pulsating heat pipes and micro-channels used in gas turbine blades for aerospace applications. In such applications, a fluid flow is required to pass through certain micro-passages such as micro-grooves and micro-channels. The fluid flow characteristics (flow rate, turbulence, pressure drop and fluid dynamics) are mainly established based on the size and accuracy of micro-passages. Variations (oversizing and undersizing) in micro-passage's geometry directly affect the fluid flow characteristics. In this study, the micro-channels of several sizes are fabricated in well-known aerospace nickel alloy (Inconel 718) through laser beam micro-milling. The variations in geometrical characteristics of different-sized micro-channels are studied under the influences of different parameters of Nd:YAG laser. In order to have a minimum variation in the machined geometries of each size of micro-channel, the multi-objective optimization of laser parameters has been carried out utilizing the response surface methodology approach. The objective was set to achieve the targeted top widths and depths of micro-channels with minimum degree of taperness associated with the micro-channel's sidewalls. The optimized sets of laser parameters proposed for each size of micro-channel can be used to fabricate the micro-channels in Inconel 718 with minimum amount of geometrical variations.

  12. Heat extraction from targets in high current electron beams

    NASA Astrophysics Data System (ADS)

    Bubb, Ernest; Altemus, Rosemary; McCarthy, James; Biron, Don

    1982-12-01

    Various aspects of heat extraction from targets in high current electron beams are examined, among which are the dependences on boundary temperature, beam current density, and convective effects from an ambient gaseous environment. The design of a cooling system which extracts heat by forcing hydrogen (or helium) gas at a pressure of several Torr at near sonic velocities across a target surface is described. Boundary layer theory calculations and empirical measurements of the average heat transfer coefficient for the system are presented.

  13. Electron beam dynamics in the long-pulse, high-current DARHT-II linear induction accelerator

    SciTech Connect

    Ekdahl, Carl A; Abeyta, Epifanio O; Aragon, Paul; Archuleta, Rita; Cook, Gerald; Dalmas, Dale; Esquibel, Kevin; Gallegos, Robert A; Garnett, Robert; Harrison, James F; Johnson, Jeffrey B; Jacquez, Edward B; Mccuistian, Brian T; Montoya, Nicholas A; Nath, Subrato; Nielsen, Kurt; Oro, David; Prichard, Benjamin; Rowton, Lawrence; Sanchez, Manolito; Scarpetti, Raymond; Schauer, Martin M; Seitz, Gerald; Schulze, Martin; Bender, Howard A; Broste, William B; Carlson, Carl A; Frayer, Daniel K; Johnson, Douglas E; Tom, C Y; Williams, John; Hughes, Thomas; Anaya, Richard; Caporaso, George; Chambers, Frank; Chen, Yu - Jiuan; Falabella, Steve; Guethlein, Gary; Raymond, Brett; Richardson, Roger; Trainham, C; Weir, John; Genoni, Thomas; Toma, Carsten

    2009-01-01

    The DARHT-II linear induction accelerator (LIA) now accelerates 2-kA electron beams to more than 17 MeV. This LIA is unique in that the accelerated current pulse width is greater than 2 microseconds. This pulse has a flat-top region where the final electron kinetic energy varies by less than 1% for more than 1.5 microseconds. The long risetime of the 6-cell injector current pulse is 0.5 {micro}s, which can be scraped off in a beam-head cleanup zone before entering the 68-cell main accelerator. We discuss our experience with tuning this novel accelerator; and present data for the resulting beam transport and dynamics. We also present beam stability data, and relate these to previous stability experiments at lower current and energy.

  14. Neutral beam current drive scaling in DIII-D

    SciTech Connect

    Porter, G.D.; Bhadra, D.K.; Burrell, K.H.; Callis, R.W.; Colleraine, A.P.; Ferron, J.R.; James, R.A.; Kellman, A.G.; Kim, J.; Matsuoka, M.

    1989-03-01

    Neutral beam current drive scaling experiments have been carried out on the DIII-D tokamak at General Atomics. These experiments were performed using up to 10 MW of 80 keV hydrogen beams. Previous current drive experiments on DIII-D have demonstrated beam driven currents up to 340 kA. In the experiments reported here we achieved beam driven currents of at least 500 kA, and have obtained operation with record values of poloidal beta (epsilon..beta../sub p/ = 1.4). The beam driven current reported here is obtained from the total plasma current by subtracting an estimate of the residual Ohmic current determined from the measured loop voltage. In this report we discuss the scaling of the current drive efficiency with plasma conditions. Using hydrogen neutral beams, we find the current drive efficiency is similar in Deuterium and Helium target plasmas. Experiments have been performed with plasma electron temperatures up to T/sub e/ = 3 keV, and densities in the range 2 /times/ 10/sup 19/m/sup /minus/3/ < n/sub e/ < 4 /times/ 10/sup 19/m/sup /minus/3/. The current drive efficiency (nIR/P) is observed to scale linearly with the energy confinement time on DIII-D to a maximum of 0.05 /times/ 10/sup 20/m/sup /minus/2/ A/W. The measured efficiency is consistent with a 0-D theoretical model. In addition to comparison with this simple model, detailed analysis of several shots using the time dependent transport code ONETWO is discussed. This analysis indicates that bootstrap current contributes approximately 10--20% of the the total current. Our estimates of this effect are somewhat uncertain due to limited measurements of the radial profile of the density and temperatures. 4 refs., 1 fig., 1 tab.

  15. Multi-strip silicon sensors for beam array monitoring in micro-beam radiation therapy.

    PubMed

    Alagoz, E; Brauer-Krisch, E; Bravin, A; Cornelius, I; Fournier, P; Hansen, T E; Kok, A; Lerch, M; Monakhov, E; Morse, J; Pacifico, N; Petasecca, M; Povoli, M; Requard, H; Rozenfeld, A D; Salome, M; Sandaker, H; Stugu, B

    2016-12-01

    We present here the latest results from tests performed at the ESRF ID17 and ID21 beamlines for the characterization of novel beam monitors for Microbeam Radiation Therapy (MRT), which is currently being implemented at ID17. MRT aims at treating solid tumors by exploiting an array of evenly spaced microbeams, having an energy spectrum distributed between 27 and 600keV and peaking at 100keV. Given the high instantaneous dose delivered (up to 20kGy/s), the position and the intensity of the microbeams has to be precisely and instantly monitored. For this purpose, we developed dedicated silicon microstrip beam monitors. We have successfully characterized them, both with a microbeam array at ID17, and a submicron scanning beam at ID21. We present here the latest results obtained in recent tests along with an outlook on future developments.

  16. System level simulation of a micro resonant accelerometer with geometric nonlinear beams

    NASA Astrophysics Data System (ADS)

    Wenlong, Jiao; Weizheng, Yuan; Honglong, Chang

    2015-10-01

    Geometric nonlinear behaviors of micro resonators have attracted extensive attention of MEMS (micro-electro-mechanical systems) researchers, and MEMS transducers utilizing these behaviors have been widely researched and used due to the advantages of essentially digital output. Currently, the design of transducers with nonlinear behaviors is mainly performed by numerical method and rarely by system level design method. In this paper, the geometric nonlinear beam structure was modeled and established as a reusable library component by system level modeling and simulation method MuPEN (multi port element network). A resonant accelerometer was constructed and simulated using this model together with MuPEN reusable library. The AC (alternating current) analysis results of MuPEN model agreed well with the results of architect model and the experiment results shown in the existing reference. Therefore, we are convinced that the beam component based on MuPEN method is valid, and MEMS system level design method and related libraries can effectively model and simulate transducers with geometric nonlinear behaviors if appropriate system level components are available.

  17. Current correlations in a Majorana beam splitter

    NASA Astrophysics Data System (ADS)

    Haim, Arbel; Berg, Erez; von Oppen, Felix; Oreg, Yuval

    2015-12-01

    We study current correlations in a T junction composed of a grounded topological superconductor and of two normal-metal leads which are biased at a voltage V . We show that the existence of an isolated Majorana zero mode in the junction dictates a universal behavior for the cross correlation of the currents through the two normal-metal leads of the junction. The cross correlation is negative and approaches zero at high bias voltages as -1 /V . This behavior is robust in the presence of disorder and multiple transverse channels, and persists at finite temperatures. In contrast, an accidental low-energy Andreev bound state gives rise to nonuniversal behavior of the cross correlation. We employ numerical transport simulations to corroborate our conclusions.

  18. Space charge templates for high-current beam modeling

    SciTech Connect

    Vorobiev, Leonid G.; /Fermilab

    2008-07-01

    A computational method to evaluate space charge potential and gradients of charged particle beam in the presence of conducting boundaries, has been introduced. The three-dimensional (3D) field of the beam can be derived as a convolution of macro Green's functions (template fields), satisfying the same boundary conditions, as the original beam. Numerical experiments gave a confidence that space charge effects can be modeled by templates with enough accuracy and generality within dramatically faster computational times than standard combination: a grid density + Poisson solvers, realized in the most of Particle in Cell codes. The achieved rapidity may significantly broaden the high-current beam design space, making the optimization in automatic mode possible, which so far was only feasible for simplest self-field formulations such as rms envelope equations. The template technique may be used as a standalone program, or as an optional field solver in existing beam dynamics codes both in one-passage structures and in rings.

  19. Plasma Charge Current for Controlling and Monitoring Electron Beam Welding with Beam Oscillation

    PubMed Central

    Trushnikov, Dmitriy; Belenkiy, Vladimir; Shchavlev, Valeriy; Piskunov, Anatoliy; Abdullin, Aleksandr; Mladenov, Georgy

    2012-01-01

    Electron beam welding (EBW) shows certain problems with the control of focus regime. The electron beam focus can be controlled in electron-beam welding based on the parameters of a secondary signal. In this case, the parameters like secondary emissions and focus coil current have extreme relationships. There are two values of focus coil current which provide equal value signal parameters. Therefore, adaptive systems of electron beam focus control use low-frequency scanning of focus, which substantially limits the operation speed of these systems and has a negative effect on weld joint quality. The purpose of this study is to develop a method for operational control of the electron beam focus during welding in the deep penetration mode. The method uses the plasma charge current signal as an additional informational parameter. This parameter allows identification of the electron beam focus regime in electron-beam welding without application of additional low-frequency scanning of focus. It can be used for working out operational electron beam control methods focusing exactly on the welding. In addition, use of this parameter allows one to observe the shape of the keyhole during the welding process. PMID:23242276

  20. Plasma charge current for controlling and monitoring electron beam welding with beam oscillation.

    PubMed

    Trushnikov, Dmitriy; Belenkiy, Vladimir; Shchavlev, Valeriy; Piskunov, Anatoliy; Abdullin, Aleksandr; Mladenov, Georgy

    2012-12-14

    Electron beam welding (EBW) shows certain problems with the control of focus regime. The electron beam focus can be controlled in electron-beam welding based on the parameters of a secondary signal. In this case, the parameters like secondary emissions and focus coil current have extreme relationships. There are two values of focus coil current which provide equal value signal parameters. Therefore, adaptive systems of electron beam focus control use low-frequency scanning of focus, which substantially limits the operation speed of these systems and has a negative effect on weld joint quality. The purpose of this study is to develop a method for operational control of the electron beam focus during welding in the deep penetration mode. The method uses the plasma charge current signal as an additional informational parameter. This parameter allows identification of the electron beam focus regime in electron-beam welding without application of additional low-frequency scanning of focus. It can be used for working out operational electron beam control methods focusing exactly on the welding. In addition, use of this parameter allows one to observe the shape of the keyhole during the welding process.

  1. Flow sensing by buckling monitoring of electrothermally actuated double-clamped micro beams

    NASA Astrophysics Data System (ADS)

    Kessler, Y.; Krylov, S.; Liberzon, A.

    2016-08-01

    We report on a flow sensing approach based on deflection monitoring of a micro beam buckled by the compressive thermal stress due to electrothermal Joule's heating. The air stream, convectively cooling the device, affects both the critical buckling values of the electric current and the postbuckling deflections of the structure. After calibration, the flow velocity can be obtained from the deflection measurements. The quasi-static responses of 1000 μm and 2000 μm long, 10 μm wide, and 30 μm high single crystal silicon beams were consistent with the prediction of the model, which couples thermoelectric, thermofluidic, and structural domains. The deflection sensitivity of up to 1.5 μm/(m/s) and the critical current sensitivity of up to 0.43 mA/(m/s) were registered in the experiments. Our model and experimental results demonstrate the feasibility of the sensing approach and further suggest that simple, robust, and potentially downscalable beam-type devices may have use in flow velocity and wall shear stress sensors.

  2. Versatile atomic force microscopy setup combined with micro-focused X-ray beam

    NASA Astrophysics Data System (ADS)

    Slobodskyy, T.; Zozulya, A. V.; Tholapi, R.; Liefeith, L.; Fester, M.; Sprung, M.; Hansen, W.

    2015-06-01

    Micro-focused X-ray beams produced by third generation synchrotron sources offer new perspective of studying strains and processes at nanoscale. Atomic force microscope setup combined with a micro-focused synchrotron beam allows precise positioning and nanomanipulation of nanostructures under illumination. In this paper, we report on integration of a portable commercial atomic force microscope setup into a hard X-ray synchrotron beamline. Details of design, sample alignment procedure, and performance of the setup are presented.

  3. Versatile atomic force microscopy setup combined with micro-focused X-ray beam

    SciTech Connect

    Slobodskyy, T. Tholapi, R.; Liefeith, L.; Hansen, W.; Zozulya, A. V. Fester, M.; Sprung, M.

    2015-06-15

    Micro-focused X-ray beams produced by third generation synchrotron sources offer new perspective of studying strains and processes at nanoscale. Atomic force microscope setup combined with a micro-focused synchrotron beam allows precise positioning and nanomanipulation of nanostructures under illumination. In this paper, we report on integration of a portable commercial atomic force microscope setup into a hard X-ray synchrotron beamline. Details of design, sample alignment procedure, and performance of the setup are presented.

  4. Current limiting mechanisms in electron and ion beam experiments

    NASA Technical Reports Server (NTRS)

    Olsen, R. C.

    1990-01-01

    The emission and collection of current from satellites or rockets in the ionosphere is a process which, at equilibrium, requires a balance between inward and outward currents. In most active experiments in the ionosphere and magnetosphere, the emitted current exceeds the integrated thermal current by one or more orders of magnitude. The system response is typically for the emitted current to be limited by processes such as differential charging of insulating surfaces, interactions between an emitted beam and the local plasma, and interactions between the beam and local neutral gas. These current limiting mechanisms have been illustrated for 20 years in sounding rocket and satellite experiments, which are reviewed here. Detailed presentations of the Spacecraft Charging at High Altitude (SCATHA) electron and ion gun experiments are used to demonstrate the general range of observed phenomena.

  5. Si micro-turbine by proton beam writing and porous silicon micromachining

    NASA Astrophysics Data System (ADS)

    Rajta, I.; Szilasi, S. Z.; Fürjes, P.; Fekete, Z.; Dücső, Cs.

    2009-06-01

    A 3D Si micro-turbine characterized by high aspect ratio vertical walls was formed by the combination of proton beam writing (PBW) and subsequent selective porous Si (PS) etching. Crystal damages generated by the implanted protons result in increased resistivity, thereby limit or even prevent the current to flow through the implanted area during electrochemical etching. Characteristic feature of the proposed process is that the shape of the micro electro-mechanical (MEMS) components is defined by two implantation energies. A higher energy is applied for defining the housing of the device while the lower energy is used to write the moving components. The implantation energies were selected such as to result appropriate difference between the two projected ranges, thereby providing structures with different height after development. The thickness of the walls of the moving component and the isotropic etching profile of the electrochemical PS formation was also taken into consideration. The electrochemical etching is driven until the sacrificial PS layer completely underetches the moving components, but the etch-front does not reach the bottom of the housing. Therefore, the dissolution of PS results in a ready-to-operate device with a released moving component embedded in the cavity of the housing. This work is the first demonstration of a silicon device containing a moving part made by proton beam writing.

  6. A neutron diagnostic for high current deuterium beams

    SciTech Connect

    Rebai, M.; Perelli Cippo, E.; Cavenago, M.; Dalla Palma, M.; Pasqualotto, R.; Tollin, M.; Croci, G.; Gervasini, G.; Ghezzi, F.; Grosso, G.; Tardocchi, M.; Murtas, F.; Gorini, G.

    2012-02-15

    A neutron diagnostic for high current deuterium beams is proposed for installation on the spectral shear interferometry for direct electric field reconstruction (SPIDER, Source for Production of Ion of Deuterium Extracted from RF plasma) test beam facility. The proposed detection system is called Close-contact Neutron Emission Surface Mapping (CNESM). The diagnostic aims at providing the map of the neutron emission on the beam dump surface by placing a detector in close contact, right behind the dump. CNESM uses gas electron multiplier detectors equipped with a cathode that also serves as neutron-proton converter foil. The cathode is made of a thin polythene film and an aluminium film; it is designed for detection of neutrons of energy >2.2 MeV with an incidence angle < 45 deg. CNESM was designed on the basis of simulations of the different steps from the deuteron beam interaction with the beam dump to the neutron detection in the nGEM. Neutron scattering was simulated with the MCNPX code. CNESM on SPIDER is a first step towards the application of this diagnostic technique to the MITICA beam test facility, where it will be used to resolve the horizontal profile of the beam intensity.

  7. microRNA-208a in an early stage myocardial infarction rat model and the effect on cAMP-PKA signaling pathway.

    PubMed

    Feng, Gao; Yan, Zhang; Li, Chuanchuan; Hou, Yuemei

    2016-08-01

    The expression level of microRNA-208a (miR-208a) in a rat model with myocardial infarction and the effect of cAMP-PKA signaling pathway in early stage of myocardial infarction in rats were investigated. The early myocardial infarction model was established in 12 male Sprague-Dawley rats by ligation of the anterior descending coronary artery, and 12 rats were selected as the control group (sham operation group). Reverse-transcription quantitative PCR was conducted to detect the expression levels of miR-208a in the myocardium of and the expression levels of miR‑208a in the serum of rats in the two groups. Western blot analysis was used to evaluate the expression levels of cAMP-PKA protein in the rat tissues in the two groups. After stimulating high levels of miR‑208a expression in human myocardial cells (HCM), western blot analysis was used to detect the cAMP-PKA protein levels. The expression levels of miR‑208a in myocardial tissues in rats with myocardial infarction were significantly higher than those in the control group, and the difference was statistically significant (P<0.05). The expression levels of miR‑208a in the early stage of myocardial infarction rats were also significantly higher than those in the control group, and the difference was statistically significant (P<0.05). The level of cAMP-PKA protein in myocardial tissue in rats with chronic myocardial infarction was also significantly higher. Transfection of human myocardial cells with miR‑208a analogue significantly increased the cAMP-PKA protein levels in human myocardial cells. In conclusion, the over-expression of miR-208a in myocardial infarction tissue and the high levels of this miRNA in the serum, may be involved in the process of myocardial infarction by influencing the cAMP-PKA signaling pathway in myocardial cells.

  8. Low Starting Electron Beam Current in Degenerate Band Edge Oscillators

    NASA Astrophysics Data System (ADS)

    Othman, Mohamed A. K.; Veysi, Mehdi; Figotin, Alexander; Capolino, Filippo

    2016-06-01

    We propose a new principle of operation in vacuum electron-beam-based oscillators that leads to a low beam current for starting oscillations. The principle is based on super synchronous operation of an electron beam interacting with four degenerate electromagnetic modes in a slow-wave structure (SWS). The four mode super synchronous regime is associated with a very special degeneracy condition in the dispersion diagram of a cold periodic SWS called degenerate band edge (DBE). This regime features a giant group delay in the finitelength SWS and low starting-oscillation beam current. The starting beam current is at least an order of magnitude smaller compared to a conventional backward wave oscillator (BWO) of the same length. As a representative example we consider a SWS conceived by a periodically-loaded metallic waveguide supporting a DBE, and investigate starting-oscillation conditions using Pierce theory generalized to coupled transmission lines (CTL). The proposed super synchronism regime can be straightforwardly adapted to waveguide geometries others than the periodically-loaded waveguide considered here since DBE is a general property that can be realized in a variety of structures.

  9. Multistable wireless micro-actuator based on antagonistic pre-shaped double beams

    NASA Astrophysics Data System (ADS)

    Liu, X.; Lamarque, F.; Doré, E.; Pouille, P.

    2015-07-01

    This paper presents a monolithic multistable micro-actuator based on antagonistic pre-shaped double beams. The designed micro-actuator is formed by two rows of bistable micro-actuators providing four stable positions. The bistable mechanism for each row is a pair of antagonistic pre-shaped beams. This bistable mechanism has an easier pre-load operation compared to the pre-compressed bistable beams method. Furthermore, it solves the asymmetrical force output problem of parallel pre-shaped bistable double beams. At the same time, the geometrical limit is lower than parallel pre-shaped bistable double beams, which ensures a smaller stroke of the micro-actuator with the same dimensions. The designed micro-actuator is fabricated using laser cutting machine on medium density fiberboard (MDF). The bistability and merits of antagonistic pre-shaped double beams are experimentally validated. Finally, a contactless actuation test is performed using 660 nm wavelength laser heating shape memory alloy (SMA) active elements.

  10. Return Current Electron Beams and Their Generation of "Raman" Scattering

    NASA Astrophysics Data System (ADS)

    Simon, A.

    1998-11-01

    For some years, we(A. Simon and R. W. Short, Phys. Rev. Lett. 53), 1912 (1984). have proposed that the only reasonable explanation for many of the observations of "Raman" scattering is the presence of an electron beam in the plasma. (The beam creates a bump-on-tail instability.) Two major objections to this picture have been observation of Raman when no n_c/4 surface was present, with no likely source for the electron beam, and the necessity for the initially outward directed beam to bounce once to create the proper waves. Now new observations on LLE's OMEGA(R. Petrasso et al), this conference. and at LULI(C. Labaune et al)., Phys. Plasma 5, 234 (1998). have suggested a new origin for the electron beam. This new scenario answers the previous objections, maintains electron beams as the explanation of the older experiments, and may clear up puzzling observations that have remained unexplained. The new scenario is based on two assumptions: (1) High positive potentials develop in target plasmas during their creation. (2) A high-intensity laser beam initiates spark discharges from nearby surfaces to the target plasma. The resulting return current of electrons should be much more delta-like, is initially inwardly directed, and no longer requires the continued presence of a n_c/4 surface. Scattering of the interaction beam from the BOT waves yields the observed Raman signal. Experimental observations that support this picture will be cited. ``Pulsation'' of the scattering and broadband ``flashes'' are a natural part of this scenario. This work was supported by the U.S. Department of Energy Office of Inertial Confinement Fusion under Cooperative Agreement No. DE-FC03-92SF19460.

  11. Broad-beam, high current, metal ion implantation facility

    SciTech Connect

    Brown, I.G.; Dickinson, M.R.; Galvin, J.E.; Godechot, X.; MacGill, R.A.

    1990-07-01

    We have developed a high current metal ion implantation facility with which high current beams of virtually all the solid metals of the Periodic Table can be produced. The facility makes use of a metal vapor vacuum arc ion source which is operated in a pulsed mode, with pulse width 0.25 ms and repetition rate up to 100 pps. Beam extraction voltage is up to 100 kV, corresponding to an ion energy of up to several hundred keV because of the ion charge state multiplicity; beam current is up to several Amperes peak and around 10 mA time averaged delivered onto target. Implantation is done in a broad-beam mode, with a direct line-of-sight from ion source to target. Here we describe the facility and some of the implants that have been carried out using it, including the seeding' of silicon wafers prior to CVD with titanium, palladium or tungsten, the formation of buried iridium silicide layers, and actinide (uranium and thorium) doping of III-V compounds. 16 refs., 6 figs.

  12. determination of current density distribution in an electron beam

    NASA Astrophysics Data System (ADS)

    Kandel, Yudhishthir Prasad

    Electron beams are useful in many applications because they can be focused down to a spot far exceeding the physical limit of focusing visible light or x-rays. Additionally, electron beams are useful in transferring concentrated amounts of energy to a very small well defined region of a target for a fixed duration. This has led to the development of both scanning electron microscopes (SEMs) and electron beam lithography. The goal of this work was to develop a general method that accurately and easily yields the best estimate of the electron current density distribution of a focused electron beam, known as point spread function (PSF). The method developed is fast, easy to use and accurate. Two specific areas of research have been addressed for PSF determination. The first is concerned with the monotonic response of EUV photoresist as a function of electron beam dose. An external metrology is used for mapping the change in thickness that is smaller than the beam spot size. The method developed in this study simultaneously gives the photo-resist thickness change as a function of electron dose and electron beam PSF. A second thrust of this research has been to develop set of PSF characterization approaches that apply to the SEM. Here a knowledge of the PSF offers many benefits including the ability to monitor and optimize SEM performance such as astigmatism control. Perhaps, even more importantly, a knowledge of the PSF combined with a series of well-defined experimental steps has led to the development of new methods for improving the resolution of SEM images through computational means rather than very costly and complex equipment modification.

  13. Vibration attenuation of conductive beams by inducing eddy currents

    NASA Astrophysics Data System (ADS)

    Irazu, L.; Elejabarrieta, M. J.

    2016-09-01

    The increasing requirements for structural vibration control in many industries, require innovative attenuation techniques. In this work, the phenomenon of eddy currents is proposed to reduce the vibration of conductive and non-magnetic beam-like structures without modifying the system, neither the weight nor the stiffness. The motion of a conductive material in a stationary magnetic field induces eddy currents, which in turn generate a repulsive force and attenuate the vibration. In this study, the vibrational response of a thin aluminium beam under a partial and stationary magnetic field is analysed. The influence of the eddy currents is experimentally studied in the bandwidth from 0 to 1 kHz and a preliminary numerical model is proposed. The results show the vibration of all the length of the beam can be attenuated by inducing eddy currents, whereas the natural frequencies of the system remain unmodified. The attenuation of the vibration is more remarkable at low frequencies and when the position of the magnetic field coincides with a maximum vibration of a mode.

  14. Binary micro optics: An application to beam steering

    SciTech Connect

    Goltsos, W.; Holz, M.

    1989-01-01

    Agile steering of a helium-neon laser beam (lambda = 632.8nm) was demonstrated using a complementary pair of 5-cm-aperture diffractive microlens arrays in the Galilean telescopic geometry. Having as many as 60,000 F/5 microlenses, each with parabolic phase profile and 200 micrometers diameter, results in nearly aberration-free beam steering over 11 deg. field of view for top + or - 100 micrometers lateral displacements of one array relative to the other. Wavefront quality and steering efficiency of the deflected beam has been measured as a function of steering angle and is compared to a simple theoretical model.

  15. Beam position and total current monitor for heavy ion fusion beams

    SciTech Connect

    Berners, D.; Reginato, L.L.

    1992-10-01

    Heavy Ion Fusion requires moderate currents, 1-10A, for a duration of about 1 {mu}s. For accurate beam transport, the center of charge must be located to within {plus_minus} 100 {mu}m. Beam position and intensity may be excited at frequencies approaching 10 MHz, and the monitoring system must have adequate bandwidth to respond at these frequencies. We have modified the Rogowski technique by using distributed reactance multiturn magnetic loops so that it is suitable for measuring current position as well as amplitude. Four identical stripline coils are wound one per quadrant around a non magnetic core. The sensitivity is similar to that of a lumped coil system, with the added advantage of increased bandwidth. The voltages induced on the four separate coils are compared and suitable signal conditioning is performed to recover beam position and intensity information.

  16. Beam position and total current monitor for heavy ion fusion beams

    SciTech Connect

    Berners, D.; Reginato, L.L.

    1992-10-01

    Heavy Ion Fusion requires moderate currents, 1-10A, for a duration of about 1 [mu]s. For accurate beam transport, the center of charge must be located to within [plus minus] 100 [mu]m. Beam position and intensity may be excited at frequencies approaching 10 MHz, and the monitoring system must have adequate bandwidth to respond at these frequencies. We have modified the Rogowski technique by using distributed reactance multiturn magnetic loops so that it is suitable for measuring current position as well as amplitude. Four identical stripline coils are wound one per quadrant around a non magnetic core. The sensitivity is similar to that of a lumped coil system, with the added advantage of increased bandwidth. The voltages induced on the four separate coils are compared and suitable signal conditioning is performed to recover beam position and intensity information.

  17. The role of a microDiamond detector in the dosimetry of proton pencil beams.

    PubMed

    Gomà, Carles; Marinelli, Marco; Safai, Sairos; Verona-Rinati, Gianluca; Würfel, Jan

    2016-03-01

    In this work, the performance of a microDiamond detector in a scanned proton beam is studied and its potential role in the dosimetric characterization of proton pencil beams is assessed. The linearity of the detector response with the absorbed dose and the dependence on the dose-rate were tested. The depth-dose curve and the lateral dose profiles of a proton pencil beam were measured and compared to reference data. The feasibility of calibrating the beam monitor chamber with a microDiamond detector was also studied. It was found the detector reading is linear with the absorbed dose to water (down to few cGy) and the detector response is independent of both the dose-rate (up to few Gy/s) and the proton beam energy (within the whole clinically-relevant energy range). The detector showed a good performance in depth-dose curve and lateral dose profile measurements; and it might even be used to calibrate the beam monitor chambers-provided it is cross-calibrated against a reference ionization chamber. In conclusion, the microDiamond detector was proved capable of performing an accurate dosimetric characterization of proton pencil beams.

  18. Beam shaping for micro via drilling, dicing, and microtrimming

    NASA Astrophysics Data System (ADS)

    Lizotte, Todd E.

    2003-11-01

    The design of beam shaping optics for laser micromachining applications must be optimized for maximum beam efficiency and quality across a given image plane. The need for faster UV and IR laser processes for drilling microvias, dicing and trimming wafers led to our utilization of hybrid optics and shaping methods, where standard refractive and computer generated holographic and diffractive optics could be meshed together to construct a system that would out perform optical beam delivery technology occupying the marketplace today. This paper covers the beam shaping technology developed, the computer modeled beam shaping and propagation plots over the length of an industry standard system as well as a comparison of the computer model images to the actual results from testing, using profilometer techniques. The later portions of the paper cover the final image formed at the target plane, including uniformity, various shapes, optical efficiency and an example of image stability while using a step and scan technique through a standard galvanometer system over a 25 mm x 25 mm field size. Specific performance details will be shared with regards to total system performance as well. A further section covers a brief overview of materials processing attributes including several specific material cross sections and scanning electron images as well as various errors created by misalignment of specific elements of the shaper with respect to the beam delivery system.

  19. Hybrid monitor for both beam position and tilt of pulsed high-current beams

    SciTech Connect

    Pang, J. He, X.; Ma, C.; Zhao, L.; Li, Q.; Dai, Z.

    2014-09-15

    A Hybrid beam monitor, integrated with both azimuthal and axial B-dot probes, was designed for simultaneous measurement of both beam position and beam angle for pulsed high-current beams at the same location in beam pipe. The output signals of axial B-dot probes were found to be mixed with signals caused by transverse position deviation. In order to eliminate the unwanted signals, an elimination method was developed and its feasibility tested on a 50-Ω coaxial line test stand. By this method, a waveform, shape-like to that of input current and proportional to the tilt angle, was simulated and processed by following integration step to achieve the tilt angle. The tests showed that the measurement error of displacement and tilt angle less than 0.3 mm and 1.5 mrad, respectively. The latter error could be reduced with improved probes by reducing the inductance of the axial B-dot probe, but the improvement reached a limit due to some unknown systemic mechanism.

  20. PIXE/PIGE characterisation of emeralds using an external micro-beam

    NASA Astrophysics Data System (ADS)

    Calligaro, T.; Dran, J.-C.; Poirot, J.-P.; Querré, G.; Salomon, J.; Zwaan, J. C.

    2000-03-01

    A large collection of emeralds of various occurrences has been analysed by PIXE/PIGE in view to establish a compositional database. Major elements (Be, Si, Al) and trace elements (Li, F, Na, Mg, Ca, Rb, Cs and transition metals) are determined using an external 3 MeV proton micro-beam. Elemental micro-mapping permits to select the useful provenance tracers. This database was applied to infer the origin of several ancient emeralds set on historical jewels.

  1. Mathieu beams as versatile light moulds for 3D micro particle assemblies.

    PubMed

    Alpmann, C; Bowman, R; Woerdemann, M; Padgett, M; Denz, C

    2010-12-06

    We present tailoring of three dimensional light fields which act as light moulds for elaborate particle micro structures of variable shapes. Stereo microscopy is used for visualization of the 3D particle assemblies. The powerful method is demonstrated for the class of propagation invariant beams, where we introduce the use of Mathieu beams as light moulds with non-rotationally-symmetric structure. They offer multifarious field distributions and facilitate the creation of versatile particle structures. This general technique may find its application in micro fluidics, chemistry, biology, and medicine, to create highly efficient mixing tools, for hierarchical supramolecular organization or in 3D tissue engineering.

  2. IR image properties measurement of new micro-mirror array structure beam combiner

    NASA Astrophysics Data System (ADS)

    Li, Yanhong; Zhang, Li; Li, Zhuo

    2014-11-01

    Microwave (MW)/Infrared(IR) dual-mode compound guidance technology has greatly developed recent years for enhancing guidance precision effectively. Here a new micro-mirror array structure is introduced as upright display for MW/IR beam combiner in HWIL simulation. The beam combiner is used in the IR/MW compound HWIL system for transmitting the MW signal while reflecting the IR signal. The spatial resolution and spatial uniformity are two important performance indicators for beam combiner in the application of HWIL simulation system. In this paper, the definitions, measurement methods, and results of spatial resolution and spatial uniformity are given. Through the measurement by multiple groups of black and white stripes, the spatial resolution and the spatial uniformity can be got. It shows the micro-mirror array beam combiner can be applied for MW/IR dual-mode common-aperture HWIL simulation system.

  3. Activation of f-channels by cAMP analogues in macropatches from rabbit sino-atrial node myocytes.

    PubMed Central

    Bois, P; Renaudon, B; Baruscotti, M; Lenfant, J; DiFrancesco, D

    1997-01-01

    1. The action of the two diastereometric phosphorothioate derivatives of cAMP, Rp-cAMPs and Sp-cAMPs, was investigated on hyperpolarization-activated 'pacemaker' current (i(f)) recorded in inside-out macropatches from rabbit sino-atrial (SA) node myocytes. 2. When superfused on the intracellular side of f-channels at the concentration of 10 microM, both cAMP derivatives accelerated i(f) activation; their action was moderately less pronounced than that due to the same concentration of cAMP. 3. The measurement of the i(f) conductance-voltage relation by voltage ramp protocols indicated that both cAMP analogues shift the activation curve of i(f) to more positive voltages with no change in maximal (fully activated) conductance. 4. Dose-response relationships of the shift of the i(f) activation curve showed that both Rp-cAMPs and Sp-cAMPs act as agonists in the cAMP-dependent direct f-channel activation. Fitting data to the Hill equation resulted in maximal shifts of 9.6 and 9.5 mV, apparent dissociation constants of 0.82 and 5.4 microM, and Hill coefficients of 0.82 and 1.12 for Sp-cAMPs and Rp-cAMPs, respectively. 5. The activating action of Rp-cAMPs, a known antagonist of cAMP in the activation of cAMP-dependent protein kinase, confirms previously established evidence that f-channel activation does not involve phosphorylation. These results also suggest that the cAMP binding site of f-channels may be structurally similar to the cyclic nucleotide binding site of olfactory receptor channels. PMID:9218217

  4. First test of BNL electron beam ion source with high current density electron beam

    SciTech Connect

    Pikin, Alexander Alessi, James G. Beebe, Edward N.; Shornikov, Andrey; Mertzig, Robert; Wenander, Fredrik; Scrivens, Richard

    2015-01-09

    A new electron gun with electrostatic compression has been installed at the Electron Beam Ion Source (EBIS) Test Stand at BNL. This is a collaborative effort by BNL and CERN teams with a common goal to study an EBIS with electron beam current up to 10 A, current density up to 10,000 A/cm{sup 2} and energy more than 50 keV. Intensive and pure beams of heavy highly charged ions with mass-to-charge ratio < 4.5 are requested by many heavy ion research facilities including NASA Space Radiation Laboratory (NSRL) at BNL and HIE-ISOLDE at CERN. With a multiampere electron gun, the EBIS should be capable of delivering highly charged ions for both RHIC facility applications at BNL and for ISOLDE experiments at CERN. Details of the electron gun simulations and design, and the Test EBIS electrostatic and magnetostatic structures with the new electron gun are presented. The experimental results of the electron beam transmission are given.

  5. First test of BNL electron beam ion source with high current density electron beam

    NASA Astrophysics Data System (ADS)

    Pikin, Alexander; Alessi, James G.; Beebe, Edward N.; Shornikov, Andrey; Mertzig, Robert; Wenander, Fredrik; Scrivens, Richard

    2015-01-01

    A new electron gun with electrostatic compression has been installed at the Electron Beam Ion Source (EBIS) Test Stand at BNL. This is a collaborative effort by BNL and CERN teams with a common goal to study an EBIS with electron beam current up to 10 A, current density up to 10,000 A/cm2 and energy more than 50 keV. Intensive and pure beams of heavy highly charged ions with mass-to-charge ratio < 4.5 are requested by many heavy ion research facilities including NASA Space Radiation Laboratory (NSRL) at BNL and HIE-ISOLDE at CERN. With a multiampere electron gun, the EBIS should be capable of delivering highly charged ions for both RHIC facility applications at BNL and for ISOLDE experiments at CERN. Details of the electron gun simulations and design, and the Test EBIS electrostatic and magnetostatic structures with the new electron gun are presented. The experimental results of the electron beam transmission are given.

  6. Bunched-beam measurements of very smaller currents at ASTRID

    SciTech Connect

    Abildskov, F.; Mo/ller, S.P.

    1997-01-01

    Stored currents in low-energy ion storage rings, like ASTRID, are often very small. Absolute current measurements are nevertheless important for absolute measurements of cross sections and also for machine operation purposes. Experimental results, using a beam charge monitor (BCM) from Bergoz, are shown for both light ions (H{sup {minus}}) and heavy ions (N{sub 2}{sup +}). The velocities are low, {beta}{approximately}0.001 to 0.05, and the detected currents are in the 0.1- to 2-{mu}A range. The storage ring ASTRID, where the measurements are made, will be described. The principle of the BCM will be briefly mentioned, and the obtained performance (resolution, stability, noise, etc.) will be given. {copyright} {ital 1997 American Institute of Physics.}

  7. Cone beam CT: a current overview of devices.

    PubMed

    Nemtoi, A; Czink, C; Haba, D; Gahleitner, A

    2013-01-01

    The purpose of this study was to review and compare the properties of all the available cone beam CT (CBCT) devices offered on the market, while focusing especially on Europe. In this study, we included all the different commonly used CBCT devices currently available on the European market. Information about the properties of each device was obtained from the manufacturers' official available data, which was later confirmed by their representatives in cases where it was necessary. The main features of a total of 47 CBCT devices that are currently marketed by 20 companies were presented, compared and discussed in this study. All these CBCT devices differ in specific properties according to the companies that produce them. The summarized technical data from a large number of CBCT devices currently on the market offer a wide range of imaging possibilities in the oral and maxillofacial region.

  8. Cone beam CT: a current overview of devices

    PubMed Central

    Nemtoi, A; Czink, C; Haba, D; Gahleitner, A

    2013-01-01

    The purpose of this study was to review and compare the properties of all the available cone beam CT (CBCT) devices offered on the market, while focusing especially on Europe. In this study, we included all the different commonly used CBCT devices currently available on the European market. Information about the properties of each device was obtained from the manufacturers’ official available data, which was later confirmed by their representatives in cases where it was necessary. The main features of a total of 47 CBCT devices that are currently marketed by 20 companies were presented, compared and discussed in this study. All these CBCT devices differ in specific properties according to the companies that produce them. The summarized technical data from a large number of CBCT devices currently on the market offer a wide range of imaging possibilities in the oral and maxillofacial region. PMID:23818529

  9. Rectangular-apertured micro-Fresnel lens arrays fabricated by electron-beam lithography.

    PubMed

    Shiono, T; Setsune, K; Yamazaki, O; Wasa, K

    1987-02-01

    Rectangular-apertured micro-Fresnel lens arrays are proposed. These lens arrays have been fabricated by an electron-beam writing system specially developed for the fabrication of microoptical devices. It is experimentally demonstrated that the lens arrays showed uniform focusing characteristics, and that each lens exhibited a diffraction-limited focusing characteristic with efficiency of 74%.

  10. Sparing of tissue by using micro-slit-beam radiation therapy reduces neurotoxicity compared with broad-beam radiation therapy

    PubMed Central

    Mukumoto, Naritoshi; Nakayama, Masao; Akasaka, Hiroaki; Shimizu, Yasuyuki; Osuga, Saki; Miyawaki, Daisuke; Yoshida, Kenji; Ejima, Yasuo; Miura, Yasushi; Umetani, Keiji; Kondoh, Takeshi; Sasaki, Ryohei

    2017-01-01

    Micro-slit-beam radiation therapy (MRT) using synchrotron-generated X-ray beams allows for extremely high-dose irradiation. However, the toxicity of MRT in central nervous system (CNS) use is still unknown. To gather baseline toxicological data, we evaluated mortality in normal mice following CNS-targeted MRT. Male C57BL/6 J mice were head-fixed in a stereotaxic frame. Synchrotron X-ray-beam radiation was provided by the SPring-8 BL28B2 beam-line. For MRT, radiation was delivered to groups of mice in a 10 × 12 mm unidirectional array consisting of 25-μm-wide beams spaced 100, 200 or 300 μm apart; another group of mice received the equivalent broad-beam radiation therapy (BRT) for comparison. Peak and valley dose rates of the MRT were 120 and 0.7 Gy/s, respectively. Delivered doses were 96–960 Gy for MRT, and 24–120 Gy for BRT. Mortality was monitored for 90 days post-irradiation. Brain tissue was stained using hematoxylin and eosin to evaluate neural structure. Demyelination was evaluated by Klüver–Barrera staining. The LD50 and LD100 when using MRT were 600 Gy and 720 Gy, respectively, and when using BRT they were 80 Gy and 96 Gy, respectively. In MRT, mortality decreased as the center-to-center beam spacing increased from 100 μm to 300 μm. Cortical architecture was well preserved in MRT, whereas BRT induced various degrees of cerebral hemorrhage and demyelination. MRT was able to deliver extremely high doses of radiation, while still minimizing neuronal death. The valley doses, influenced by beam spacing and irradiated dose, could represent important survival factors for MRT. PMID:27422939

  11. Dosimetric characterization of a microDiamond detector in clinical scanned carbon ion beams

    SciTech Connect

    Marinelli, Marco; Prestopino, G. Verona, C.; Verona-Rinati, G.; Ciocca, M.; Mirandola, A.; Mairani, A.; Raffaele, L.; Magro, G.

    2015-04-15

    Purpose: To investigate for the first time the dosimetric properties of a new commercial synthetic diamond detector (PTW microDiamond) in high-energy scanned clinical carbon ion beams generated by a synchrotron at the CNAO facility. Methods: The detector response was evaluated in a water phantom with actively scanned carbon ion beams ranging from 115 to 380 MeV/u (30–250 mm Bragg peak depth in water). Homogeneous square fields of 3 × 3 and 6 × 6 cm{sup 2} were used. Short- and medium-term (2 months) detector response stability, dependence on beam energy as well as ion type (carbon ions and protons), linearity with dose, and directional and dose-rate dependence were investigated. The depth dose curve of a 280 MeV/u carbon ion beam, scanned over a 3 × 3 cm{sup 2} area, was measured with the microDiamond detector and compared to that measured using a PTW Advanced Markus ionization chamber, and also simulated using FLUKA Monte Carlo code. The detector response in two spread-out-Bragg-peaks (SOBPs), respectively, centered at 9 and 21 cm depths in water and calculated using the treatment planning system (TPS) used at CNAO, was measured. Results: A negligible drift of detector sensitivity within the experimental session was seen, indicating that no detector preirradiation was needed. Short-term response reproducibility around 1% (1 standard deviation) was found. Only 2% maximum variation of microDiamond sensitivity was observed among all the evaluated proton and carbon ion beam energies. The detector response showed a good linear behavior. Detector sensitivity was found to be dose-rate independent, with a variation below 1.3% in the evaluated dose-rate range. A very good agreement between measured and simulated Bragg curves with both microDiamond and Advanced Markus chamber was found, showing a negligible LET dependence of the tested detector. A depth dose curve was also measured by positioning the microDiamond with its main axis oriented orthogonally to the beam

  12. Design beam shapers with double freeform surfaces to form a desired wavefront with prescribed illumination pattern by solving a Monge-Ampère type equation

    NASA Astrophysics Data System (ADS)

    Chang, Shengqian; Wu, Rengmao; An, Li; Zheng, Zhenrong

    2016-12-01

    Beam shaping, in other words, the control of both intensity distribution and phase profile, has a wide range of applications. In this paper, double freeform surfaces are utilized to shape collimated beams, realizing an arbitrary output wavefront with desired illumination pattern. Freeform surfaces are designed by solving a second order partial differential equation (PDE) of the Monge-Ampère (MA) type, without the limitation of symmetry or paraxial approximation. The mathematical derivation of the PDE is based on the Snell’s law, the energy conservation law along infinitesimal tubes of rays and the constancy of the OPL. The PDE is discretized with a finite difference scheme into a system of nonlinear equations, which can be numerically solved by Newton’s method. Since Newton’s method requires a good initialization for the iteration, a simultaneously point-by-point method, based on ray mapping, is employed to find the initial iterate. Different design examples are given to demonstrate the effectiveness and wide application of our method, transforming a collimated Gaussian beam into a spherical wavefront with uniform illumination patterns. Variable-sized uniform illumination pattern can be obtained by moving the observation plane due to a potential benefit of the spherical output wavefront.

  13. Resolution improvement and pattern generator development for the maskless micro-ion-beam reduction lithography system

    NASA Astrophysics Data System (ADS)

    Jiang, Ximan

    have been studied. The dependence of the throughput with the exposure field size and the speed of the mechanical stage has been investigated. In order to perform maskless lithography, different micro-fabricated pattern generators have been developed for the MMRL system. Ion beamlet switching has been successfully demonstrated on the MMRL system. A positive bias voltage around 10 volts is sufficient to switch off the ion current on the micro-fabricated pattern generators. Some unexpected problems, such as the high-energy secondary electron radiations, have been discovered during the experimental investigation. Thermal and structural analysis indicates that the aperture displacement error induced by thermal expansion can satisfy the 3delta CD requirement for lithography nodes down to 25 nm. The cross-talking effect near the surface and inside the apertures of the pattern generator has been simulated in a 3-D ray-tracing code. New pattern generator design has been proposed to reduce the cross-talking effect. In order to eliminate the surface charging effect caused by the secondary electrons, a new beam-switching scheme in which the switching electrodes are immersed in the plasma has been demonstrated on a mechanically fabricated pattern generator.

  14. Depletion region surface effects in electron beam induced current measurements

    PubMed Central

    Haney, Paul M.; Yoon, Heayoung P.; Gaury, Benoit; Zhitenev, Nikolai B.

    2016-01-01

    Electron beam induced current (EBIC) is a powerful characterization technique which offers the high spatial resolution needed to study polycrystalline solar cells. Current models of EBIC assume that excitations in the p-n junction depletion region result in perfect charge collection efficiency. However we find that in CdTe and Si samples prepared by focused ion beam (FIB) milling, there is a reduced and nonuniform EBIC lineshape for excitations in the depletion region. Motivated by this, we present a model of the EBIC response for excitations in the depletion region which includes the effects of surface recombination from both charge-neutral and charged surfaces. For neutral surfaces we present a simple analytical formula which describes the numerical data well, while the charged surface response depends qualitatively on the location of the surface Fermi level relative to the bulk Fermi level. We find the experimental data on FIB-prepared Si solar cells is most consistent with a charged surface, and discuss the implications for EBIC experiments on polycrystalline materials. PMID:27881882

  15. High-energy tritium beams as current drivers in tokamak reactors

    SciTech Connect

    Mikkelsen, D.R.; Grisham, L.R.

    1983-04-01

    The effect on neutral-beam design and reactor performance of using high-energy (approx. 3-10 MeV) tritium neutral beams to drive steady-state tokamak reactors is considered. The lower current of such beams leads to several advantages over lower-energy neutral beams. The major disadvantage is the reduction of the reactor output caused by the lower current-drive efficiency of the high-energy beams.

  16. Symmetry Breaking Criteria in Electrostatically Loaded Bistable Curved/Prebuckled Micro Beams

    NASA Astrophysics Data System (ADS)

    Medina, Lior; Gilat, Rivka; Krylov, Slava

    The symmetric and asymmetric buckling of micro beams subjected to distributed electrostatic force is studied. The analysis is carried out for two separate cases: a case of a stress-free beam, which is initially curved by fabrication and a case of a pre-stressed beam buckled due to an axial force. The analysis is based on a reduced order (RO) model resulting from the Galerkin decomposition with vibrational or buckling modes of a straight beam used as the base functions. The criteria of symmetric, limit point, buckling and of non-symmetric bifurcation are derived in terms of the geometric parameters of the beams. While the necessary symmetry breaking criterion establishes the conditions for the appearance of bifurcation points on the unstable branch of the symmetric limit point buckling curve, the sufficient criterion assures a realistic asymmetric buckling bifurcating from the stable branches of the symmetric equilibrium path. It is shown that while the symmetry breaking conditions are affected by the nonlinearity of the electrostatic force, its influence is less pronounced than in the case of the symmetric snap-through. A comparison between the results provided by the reduced order model, and those obtained by other numerical analyses confirms the accuracy of the symmetry breaking criteria and their applicability for the analysis and design of micro beams.

  17. Ion Beam Etching: Replication of Micro Nano-structured 3D Stencil Masks

    SciTech Connect

    Weber, Patrick; Guibert, Edouard; Mikhailov, Serguei; Bruegger, Juergen; Villanueva, Guillermo

    2009-03-10

    Ion beam LIGA allows the etching of 3D nano-structures by direct writing with a nano-sized beam. However, this is a relatively time consuming process. We propose here another approach for etching structures on large surfaces and faster, compared to the direct writing process. This approach consists of replicating 3D structured masks, by scanning an unfocused ion beam. A polymer substrate is placed behind the mask, as in UV photolithography. But the main advantage is that the 3D structure of the mask can be replicated into the polymer. For that purpose, the masks (developped at LMIS1, EPFL) are made of a silicon nitride membrane 100 nm thick, on which 3D gold structures up to 200 nm thick, are deposited. The 3D Au structures are made with the nanostencil method, based on successive gold deposition. The IMA institute, from HE-Arc, owns a High Voltage Engineering 1.7 MV Tandetron with both solid and gaseous negative ion sources, able to generate ions from almost every chemical element in a broad range of energies comprised between 400 keV and 6.8 MeV. The beam composition and energy are chosen in such a way, that ions lose a significant fraction of their energy when passing through the thickest regions of the mask. Ions passing through thinner regions of the mask loose a smaller fraction of their energy and etch the polymer with larger thicknesses, allowing a replication of the mask into the polymer. For our trials, we have used a carbon beam with an energy of 500 keV. The beam was focussed to a diameter of 5 mm with solid slits, in order to avoid border effects and thus ensure a homogeneous dose distribution on the beam diameter. The feasibility of this technique has been demonstrated, allowing industrial applications for micro-mould fabrication, micro-fluidics and micro-optics.

  18. Experimental dynamic trapping of electrostatically actuated bistable micro-beams.

    PubMed

    Medina, Lior; Gilat, Rivka; Ilic, B Robert; Krylov, Slava

    2016-02-15

    We demonstrate dynamic snap-through from a primary to a secondary statically inaccessible stable configuration in single crystal silicon, curved, doubly clamped micromechanical beam structures. Nanoscale motion of the fabricated bistable micromechanical devices was transduced using a high speed camera. Our experimental and theoretical results collectively show, that the transition between the two stable states was solely achieved by a tailored time dependent electrostatic actuation. Fast imaging of micromechanical motion allowed for direct visualization of dynamic trapping at the statically inaccessible state. These results further suggest that our direct dynamic actuation transcends prevalent limitations in controlling geometrically non-linear microstructures, and may have applications extending to multi-stable, topologically optimized micromechanical logic and non-volatile memory architectures.

  19. Effects of MHD instabilities on neutral beam current drive

    SciTech Connect

    Podestà, M.; Gorelenkova, M.; Darrow, D. S.; Fredrickson, E. D.; Gerhardt, S. P.; White, R. B.

    2015-04-17

    One of the primary tools foreseen for heating, current drive (CD) and q-profile control in future fusion reactors such as ITER and a Fusion Nuclear Science Facility is the neutral beam injection (NBI). However, fast ions from NBI may also provide the drive for energetic particle-driven instabilities (e.g. Alfvénic modes (AEs)), which in turn redistribute fast ions in both space and energy, thus hampering the control capabilities and overall efficiency of NB-driven current. Based on experiments on the NSTX tokamak (M. Ono et al 2000 Nucl. Fusion 40 557), the effects of AEs and other low-frequency magneto-hydrodynamic instabilities on NB-CD efficiency are investigated. When looking at the new fast ion transport model, which accounts for particle transport in phase space as required for resonant AE perturbations, is utilized to obtain consistent simulations of NB-CD through the tokamak transport code TRANSP. It is found that instabilities do indeed reduce the NB-driven current density over most of the plasma radius by up to ~50%. Moreover, the details of the current profile evolution are sensitive to the specific model used to mimic the interaction between NB ions and instabilities. Finally, implications for fast ion transport modeling in integrated tokamak simulations are briefly discussed.

  20. Effects of MHD instabilities on neutral beam current drive

    DOE PAGES

    Podestà, M.; Gorelenkova, M.; Darrow, D. S.; ...

    2015-04-17

    One of the primary tools foreseen for heating, current drive (CD) and q-profile control in future fusion reactors such as ITER and a Fusion Nuclear Science Facility is the neutral beam injection (NBI). However, fast ions from NBI may also provide the drive for energetic particle-driven instabilities (e.g. Alfvénic modes (AEs)), which in turn redistribute fast ions in both space and energy, thus hampering the control capabilities and overall efficiency of NB-driven current. Based on experiments on the NSTX tokamak (M. Ono et al 2000 Nucl. Fusion 40 557), the effects of AEs and other low-frequency magneto-hydrodynamic instabilities on NB-CDmore » efficiency are investigated. When looking at the new fast ion transport model, which accounts for particle transport in phase space as required for resonant AE perturbations, is utilized to obtain consistent simulations of NB-CD through the tokamak transport code TRANSP. It is found that instabilities do indeed reduce the NB-driven current density over most of the plasma radius by up to ~50%. Moreover, the details of the current profile evolution are sensitive to the specific model used to mimic the interaction between NB ions and instabilities. Finally, implications for fast ion transport modeling in integrated tokamak simulations are briefly discussed.« less

  1. Demonstration of a refractometric sensor based on an optical micro-fiber three-beam interferometer

    NASA Astrophysics Data System (ADS)

    Han, Chunyang; Ding, Hui; Lv, Fangxing

    2014-12-01

    With diameter close to the wavelength of the guided light and high index contrast between the fiber and the surrounding, an optical micro-fiber shows a variety of interesting waveguiding properties, including widely tailorable optical confinement, strong evanescent fields and waveguide dispersion. Among various micro-fiber applications, optical sensing has been attracting increasing research interest due to its possibilities of realizing miniaturized fiber optic sensors with small footprint, high sensitivity, and low optical power consumption. Typical micro-fiber based sensing structures, including Michelson interferometer, Mach-Zenhder interferometer, Fabry-Perot interferometer, micro-fiber ring resonator, have been proposed. The sensitivity of these structures heavily related to the fraction of evanescent field outside micro-fiber. In this paper, we report the first theoretical and experimental study of a new type of refractometric sensor based on micro-fiber three-beam interferometer. Theoretical and experimental analysis reveals that the sensitivity is not only determined by the fraction of evanescent field outside the micro-fiber but also related to the values of interferometric arms. The sensitivity can be enhanced significantly when the effective lengths of the interferometric arms tends to be equal. We argue that this has great potential for increasing the sensitivity of refractive index detection.

  2. Demonstration of a refractometric sensor based on an optical micro-fiber three-beam interferometer.

    PubMed

    Han, Chunyang; Ding, Hui; Lv, Fangxing

    2014-12-16

    With diameter close to the wavelength of the guided light and high index contrast between the fiber and the surrounding, an optical micro-fiber shows a variety of interesting waveguiding properties, including widely tailorable optical confinement, strong evanescent fields and waveguide dispersion. Among various micro-fiber applications, optical sensing has been attracting increasing research interest due to its possibilities of realizing miniaturized fiber optic sensors with small footprint, high sensitivity, and low optical power consumption. Typical micro-fiber based sensing structures, including Michelson interferometer, Mach-Zenhder interferometer, Fabry-Perot interferometer, micro-fiber ring resonator, have been proposed. The sensitivity of these structures heavily related to the fraction of evanescent field outside micro-fiber. In this paper, we report the first theoretical and experimental study of a new type of refractometric sensor based on micro-fiber three-beam interferometer. Theoretical and experimental analysis reveals that the sensitivity is not only determined by the fraction of evanescent field outside the micro-fiber but also related to the values of interferometric arms. The sensitivity can be enhanced significantly when the effective lengths of the interferometric arms tends to be equal. We argue that this has great potential for increasing the sensitivity of refractive index detection.

  3. Electron-beam lithography for micro and nano-optical applications

    NASA Technical Reports Server (NTRS)

    Wilson, Daniel W.; Muller, Richard E.; Echternach, Pierre M.

    2005-01-01

    Direct-write electron-beam lithography has proven to be a powerful technique for fabricating a variety of micro- and nano-optical devices. Binary E-beam lithography is the workhorse technique for fabricating optical devices that require complicated precision nano-scale features. We describe a bi-layer resist system and virtual-mark height measurement for improving the reliability of fabricating binary patterns. Analog E-beam lithography is a newer technique that has found significant application in the fabrication of diffractive optical elements. We describe our techniques for fabricating analog surface-relief profiles in E-beam resist, including some discussion regarding overcoming the problems of resist heating and charging. We also describe a multiple-field-size exposure scheme for suppression of field-stitch induced ghost diffraction orders produced by blazed diffraction gratings on non-flat substrates.

  4. Current correlations in an interacting Cooper-pair beam splitter

    NASA Astrophysics Data System (ADS)

    Rech, J.; Chevallier, D.; Jonckheere, T.; Martin, T.

    2012-01-01

    We propose an approach allowing the computation of currents and their correlations in interacting multiterminal mesoscopic systems involving quantum dots coupled to normal and/or superconducting leads. The formalism relies on the expression of branching currents and noise crossed correlations in terms of one- and two-particle Green's functions for the dots electrons, which are then evaluated self-consistently within a conserving approximation. We then apply this to the Cooper-pair beam-splitter setup recently proposed [L. Hofstetter , Nature (London)NATUAS0028-083610.1038/nature08432 461, 960 (2009); Phys. Rev. Lett.PRLTAO0031-900710.1103/PhysRevLett.107.136801 107, 136801 (2011); L. G. Herrmann , Phys. Rev. Lett.PRLTAO0031-900710.1103/PhysRevLett.104.026801 104, 026801 (2010)], which we model as a double quantum dot with weak interactions, connected to a superconducting lead and two normal ones. Our method not only enables us to take into account a local repulsive interaction on the dots, but also to study its competition with the direct tunneling between dots. Our results suggest that even a weak Coulomb repulsion tends to favor positive current cross correlations in the antisymmetric regime (where the dots have opposite energies with respect to the superconducting chemical potential).

  5. Current understanding and issues on electron beam injection in space

    NASA Technical Reports Server (NTRS)

    Papadopoulos, K.; Szuszczewicz, E. P.

    1988-01-01

    The status of the physics understanding involved in electron beam injection in space is reviewed. The paper examines our understanding of beam plasma interactions and their associated wave and energized particle spectra of the processes involved in the beam plasma discharge, and of the vehicle charge neutralization. 'Strawman' models are presented for comparison with experimental observations.

  6. Using an energized oxygen micro-jet for improved graphene etching by focused electron beam

    DOE PAGES

    Kim, Songkil; Henry, Mathias; Fedorov, Andrei G.

    2015-12-07

    We report on an improved Focused Electron Beam Induced Etching (FEBIE) process, which exploits heated oxygen delivery via a continuous supersonic micro-jet resulting in faster graphene patterning and better etch feature definition. Positioning a micro-jet in close proximity to a graphene surface with minimal jet spreading due to a continuous regime of gas flow at the exit of the 10 micrometer inner diameter capillary allows for focused exposure of the surface to reactive oxygen at high mass flux and impingement energy of a supersonic gas stream localized to a small etching area exposed to electron beam. These unique benefits ofmore » focused supersonic oxygen delivery to the surface enable a dramatic increase in the etch rate of graphene with no parasitic carbon ‘halo’ deposition due to secondary electrons (SE) from backscattered electrons (BSE) in the area surrounding the etched regions. Increase of jet temperature via local nozzle heating provides means for enhancing kinetic energy of impinging oxygen molecules, which further speed up the etch, thus minimizing the beam exposure time and required electron dose, before parasitic carbon film deposition due to BSE mediated decomposition of adsorbed hydrocarbon contaminants has a measurable impact on quality of graphene etched features. Interplay of different physical mechanisms underlying an oxygen micro-jet assisted FEBIE process is discussed with support from experimental observations.« less

  7. Using an energized oxygen micro-jet for improved graphene etching by focused electron beam

    SciTech Connect

    Kim, Songkil; Henry, Mathias; Fedorov, Andrei G.

    2015-12-07

    We report on an improved Focused Electron Beam Induced Etching (FEBIE) process, which exploits heated oxygen delivery via a continuous supersonic micro-jet resulting in faster graphene patterning and better etch feature definition. Positioning a micro-jet in close proximity to a graphene surface with minimal jet spreading due to a continuous regime of gas flow at the exit of the 10 micrometer inner diameter capillary allows for focused exposure of the surface to reactive oxygen at high mass flux and impingement energy of a supersonic gas stream localized to a small etching area exposed to electron beam. These unique benefits of focused supersonic oxygen delivery to the surface enable a dramatic increase in the etch rate of graphene with no parasitic carbon ‘halo’ deposition due to secondary electrons (SE) from backscattered electrons (BSE) in the area surrounding the etched regions. Increase of jet temperature via local nozzle heating provides means for enhancing kinetic energy of impinging oxygen molecules, which further speed up the etch, thus minimizing the beam exposure time and required electron dose, before parasitic carbon film deposition due to BSE mediated decomposition of adsorbed hydrocarbon contaminants has a measurable impact on quality of graphene etched features. Interplay of different physical mechanisms underlying an oxygen micro-jet assisted FEBIE process is discussed with support from experimental observations.

  8. Using an energized oxygen micro-jet for improved graphene etching by focused electron beam

    SciTech Connect

    Kim, Songkil; Henry, Mathias; Fedorov, Andrei G.

    2015-12-07

    We report on an improved Focused Electron Beam Induced Etching (FEBIE) process, which exploits heated oxygen delivery via a continuous supersonic micro-jet resulting in faster graphene patterning and better etch feature definition. Positioning a micro-jet in close proximity to a graphene surface with minimal jet spreading due to a continuous regime of gas flow at the exit of the 10 μm inner diameter capillary allows for focused exposure of the surface to reactive oxygen at high mass flux and impingement energy of a supersonic gas stream localized to a small etching area exposed to electron beam. These unique benefits of focused supersonic oxygen delivery to the surface enable a dramatic increase in the etch rate of graphene with no parasitic carbon “halo” deposition due to secondary electrons from backscattered electrons (BSE) in the area surrounding the etched regions. Increase of jet temperature via local nozzle heating provides means for enhancing kinetic energy of impinging oxygen molecules, which further speed up the etch, thus minimizing the beam exposure time and required electron dose, before parasitic carbon film deposition due to BSE mediated decomposition of adsorbed hydrocarbon contaminants has a measurable impact on quality of graphene etched features. Interplay of different physical mechanisms underlying an oxygen micro-jet assisted FEBIE process is discussed with support from experimental observations.

  9. Region-of-interest image reconstruction in circular cone-beam microCT

    SciTech Connect

    Cho, Seungryong; Bian, Junguo; Pelizzari, Charles A.; Chen, C.-T.; He, T.-C.; Pan Xiaochuan

    2007-12-15

    Cone-beam microcomputed tomography (microCT) is one of the most popular choices for small animal imaging which is becoming an important tool for studying animal models with transplanted diseases. Region-of-interest (ROI) imaging techniques in CT, which can reconstruct an ROI image from the projection data set of the ROI, can be used not only for reducing imaging-radiation exposure to the subject and scatters to the detector but also for potentially increasing spatial resolution of the reconstructed images. Increasing spatial resolution in microCT images can facilitate improved accuracy in many assessment tasks. A method proposed previously for increasing CT image spatial resolution entails the exploitation of the geometric magnification in cone-beam CT. Due to finite detector size, however, this method can lead to data truncation for a large geometric magnification. The Feldkamp-Davis-Kress (FDK) algorithm yields images with artifacts when truncated data are used, whereas the recently developed backprojection filtration (BPF) algorithm is capable of reconstructing ROI images without truncation artifacts from truncated cone-beam data. We apply the BPF algorithm to reconstructing ROI images from truncated data of three different objects acquired by our circular cone-beam microCT system. Reconstructed images by use of the FDK and BPF algorithms from both truncated and nontruncated cone-beam data are compared. The results of the experimental studies demonstrate that, from certain truncated data, the BPF algorithm can reconstruct ROI images with quality comparable to that reconstructed from nontruncated data. In contrast, the FDK algorithm yields ROI images with truncation artifacts. Therefore, an implication of the studies is that, when truncated data are acquired with a configuration of a large geometric magnification, the BPF algorithm can be used for effective enhancement of the spatial resolution of a ROI image.

  10. cAMP/PKA Pathways and S56 Phosphorylation Are Involved in AA/PGE2-Induced Increases in rNaV1.4 Current

    PubMed Central

    Gu, Hua; Fang, Yan-Jia; Liu, Dong-Dong; Chen, Ping; Mei, Yan-Ai

    2015-01-01

    Arachidonic acid (AA) and its metabolites are important second messengers for ion channel modulation. The effects of extracellular application of AA and its non-metabolized analogue on muscle rNaV1.4 Na+ current has been studied, but little is known about the effects of intracellular application of AA on this channel isoform. Here, we report that intracellular application of AA significantly augmented the rNaV1.4 current peak without modulating the steady-state activation and inactivation properties of the rNaV1.4 channel. These results differed from the effects of extracellular application of AA on rNaV1.4 current. The effects of intracellular AA were mimicked by prostaglandin E2 but not eicosatetraynoic acid (ETYA), the non-metabolized analogue of AA, and were eliminated by treatment with cyclooxygenase inhibitors, flufenamic acid, or indomethacin. AA/PGE2-induced activation of rNaV1.4 channels was mimicked by a cAMP analogue (db-cAMP) and eliminated by a PKA inhibitor, PKAi. Furthermore, inhibition of EP2 and EP4 (PGE2 receptors) with AH6809 and AH23848 reduced the intracellular AA/PGE2-induced increase of rNaV1.4 current. Two mutated channels, rNaV1.4S56A and rNaV1.4T21A, were designed to investigate the role of predicted phosphorylation sites in the AA/PGE2–mediated regulation of rNaV1.4 currents. In rNaV1.4S56A, the effects of intracellular db-cAMP, AA, and PGE2 were significantly reduced. The results of the present study suggest that intracellular AA augments rNaV1.4 current by PGE2/EP receptor-mediated activation of the cAMP/PKA pathway, and that the S56 residue on the channel protein is important for this process. PMID:26485043

  11. Design of a bullet beam pattern of a micro ultrasound transducer (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Roh, Yongrae; Lee, Seongmin

    2016-04-01

    Ultrasonic imaging transducer is often required to compose a beam pattern of a low sidelobe level and a small beam width over a long focal region to achieve good image resolution. Normal ultrasound transducers have many channels along its azimuth, which allows easy formation of the sound beam into a desired shape. However, micro-array transducers have no control of the beam pattern along their elevation. In this work, a new method is proposed to manipulate the beam pattern by using an acoustic multifocal lens and a shaded electrode on top of the piezoelectric layer. The shading technique split an initial uniform electrode into several segments and combined those segments to compose a desired beam pattern. For a given elevation width and frequency, the optimal pattern of the split electrodes was determined by means of the OptQuest-Nonlinear Program (OQ-NLP) algorithm to achieve the lowest sidelobe level. The requirement to achieve a small beam width with a long focal region was satisfied by employing an acoustic lens of three multiple focuses. Optimal geometry of the multifocal lens such as the radius of curvature and aperture diameter for each focal point was also determined by the OQ-NLP algorithm. For the optimization, a new index was devised to evaluate the on-axis response: focal region ratio = focal region / minimum beam width. The larger was the focal region ratio, the better was the beam pattern. Validity of the design has been verified through fabricating and characterizing an experimental prototype of the transducer.

  12. Activation of μ-opioid receptors inhibits calcium-currents in the vestibular afferent neurons of the rat through a cAMP dependent mechanism

    PubMed Central

    Seseña, Emmanuel; Vega, Rosario; Soto, Enrique

    2014-01-01

    Opioid receptors are expressed in the vestibular endorgans (afferent neurons and hair cells) and are activated by the efferent system, which modulates the discharge of action potentials in vestibular afferent neurons (VANs). In mammals, VANs mainly express the μ opioid-receptor, but the function of this receptors activation and the cellular mechanisms by which they exert their actions in these neurons are poorly studied. To determine the actions of μ opioid receptor (MOR) and cell signaling mechanisms in VANs, we made perforated patch-clamp recordings of VANs that were obtained from postnatal days 7 to 10 (P7–10) rats and then maintained in primary culture. The MOR agonist [D-Ala2, N-Me-Phe4, Gly5-ol]-enkephalin (DAMGO) inhibited the total voltage-gated outward current; this effect was prevented by the perfusion of a Ca2+-free extracellular solution. We then studied the voltage-gated calcium current (Ica) and found that DAMGO Met-enkephalin or endomorphin-1 inhibited the ICa in a dose-response fashion. The effects of DAMGO were prevented by the MOR antagonist (CTAP) or by pertussis toxin (PTX). The use of specific calcium channel blockers showed that MOR activation inhibited T-, L- and N-type ICa. The use of various enzyme activators and inhibitors and of cAMP analogs allowed us to demonstrate that the MOR acts through a cAMP dependent signaling mechanism. In current clamp experiments, MOR activation increased the duration and decreased the amplitude of the action potentials and modulated the discharge produced by current injection. Pre-incubation with PTX occluded MOR activation effect. We conclude that MOR activation inhibits the T-, L- and N-type ICa through activation of a Gαi/o protein that involves a decrease in AC-cAMP-PKA activity. The modulation of ICa may have an impact on the synaptic integration, excitability, and neurotransmitter release from VANs. PMID:24734002

  13. Micro drilling using deformable mirror for beam shaping of ultra-short laser pulses

    NASA Astrophysics Data System (ADS)

    Smarra, Marco; Strube, Anja; Dickmann, Klaus

    2016-03-01

    Using ultra-short laser pulses for micro structuring or drilling applications reduces the thermal influence to the surrounding material. The best achievable beam profile equals a Gaussian beam. Drilling with this beam profile results in cylindrical holes. To vary the shape of the holes, the beam can either be scanned or - for single pulse and percussion drilling - manipulated by masks or lenses. A high flexible method for beam shaping can be realized by using a deformable mirror. This mirror contains a piezo-electric ceramic, which can be deformed by an electric potential. By separating the ceramic into independent controllable segments, the shape of the surface can be varied individually. Due to the closed surface of the mirror, there is no loss of intensity due to diffraction. The mirror deformation is controlled by Zernike polynomials and results e.g. in a lens behavior. In this study a deformable mirror was used to generate e.g. slits in thin steel foils by percussion drilling using ultra-short laser pulses. The influence of the cylindrical deformation to the laser beam and the resulting geometry of the generated holes was studied. It was demonstrated that due to the high update rate up to 150 Hz the mirror surface can be varied in each scan cycle, which results in a high flexible drilling process.

  14. Nano and micro structured targets to modulate the spatial profile of laser driven proton beams

    NASA Astrophysics Data System (ADS)

    Giuffrida, L.; Svensson, K.; Psikal, J.; Margarone, D.; Lutoslawski, P.; Scuderi, V.; Milluzzo, G.; Kaufman, J.; Wiste, T.; Dalui, M.; Ekerfelt, H.; Gallardo Gonzalez, I.; Lundh, O.; Persson, A.; Picciotto, A.; Crivellari, M.; Bagolini, A.; Bellutti, P.; Magnusson, J.; Gonoskov, A.; Klimsa, L.; Kopecek, J.; Lastovicka, T.; Cirrone, G. A. P.; Wahlström, C.-G.; Korn, G.

    2017-03-01

    Nano and micro structured thin (μ m-scale) foils were designed, fabricated and irradiated with the high intensity laser system operating at LLC (Lund Laser Centre, Sweden) in order to systematically study and improve the main proton beam parameters. Nano-spheres deposited on the front (laser irradiated) surface of a flat Mylar foil enabled a small enhancement of the maximum energy and number of the accelerated protons. Nano-spheres on the rear side allowed to modify the proton beam spatial profile. In particular, with nanospheres deposited on the rear of the target, the proton beam spatial homogeneity was clearly enhanced. Silicon nitride thin foils having micro grating structures (with different step dimensions) on the rear surface were also used as targets to influence the divergence of the proton beam and drastically change its shape through a sort of stretching effect. The target fabrication process used for the different target types is described, and representative experimental results are shown and discussed along with supporting 3D particle-in-cell simulations.

  15. Beam steering and deflecting device using step-based micro-blazed grating

    NASA Astrophysics Data System (ADS)

    Yang, Junbo; Su, Xianyu; Xu, Ping; Gu, Zheng

    2008-08-01

    The rapidly evolving demands of optical communications and optical switching systems have created a new market for high capacity all-optical beam steering and deflecting techniques. One technology potentially capable of realizing such systems uses the multistep micro-blazed grating optical beam deflectors based on binary and multiple-phase modulation methods. The micro-optical element has been fabricated by introducing very large scale integration (VLSI), stepping photolithography and reactive ion etching (RIE), which can realize beam steering, deflecting, splitting, and switching in free space, and its diffraction properties are determined by the blazed-grating parameters, such as the number of steps, grating depth, grating period, as well as blazed profile. The theoretical analysis and primarily experimental result show that this phase-type element has the advantages of high diffractive efficiency, low cross talk, small feature size, and high reliability due to nonmechanical beam steering without any moving parts. Hence it is ideally suited to applications in optical communication and optical interconnection network.

  16. MICRO-BUNCHING OF THE AGS SLOW EXTRACTED BEAM FOR A RARE KAON DECAY SEARCH.

    SciTech Connect

    GLENN,J.; SIVERTZ,M.; CHIANG,I.; LAZARUS,D.; KOSCIELNIAK,S.

    2001-06-18

    The AGS Slow Extracted Beam (SEB) must be chopped with 250 ps bursts every 40 ns to permit time-of-flight (ToF) measurement of the secondary K{sup 0} beam. Standard techniques to produce this level of bunching would require excessive rf voltage, thus we have developed a ''Micro-Bunching'' technique of extracting the beam as it is forced between empty rf buckets. A specification of the required rf system will be given. Four-dimensional model simulations of particle dynamics for the planned rf and extraction systems will be shown. Simulations of previous tests along with the test measurements are also presented. Measurement of tight bunching requires dedicated instrumentation. The design of a detector system to measure bunch widths and the extinction factor between bunches will be given; considerations include the various particles produced and transported, timing precision and background.

  17. Study on controllable LC-micro blazed grating beam deflector in free space

    NASA Astrophysics Data System (ADS)

    Yang, Junbo; Xu, Suzhi; Zhang, Jingjing; Chang, Shengli

    2015-02-01

    A liquid crystal (LC) beam deflector with a microblazed grating produced by stepping photolithography and reactive ion etching (RIE) was reported. A homogeneously aligned nematic liquid crystal (NLC) materials are filled inside the microcavity of blazed grating, and sandwiched between two glass plates. An indium tin oxide (ITO) transparent electrode is deposited on it to provide the beam steering capability. Our LC-micro blazed grating device gives a high diffractive efficiency (about 95%) and a controllable large steering angle over 7.2° (for ne) and 1.7° (for no), respectively. It was found that this type of non-mechanical beam steering without any moving parts is ideally suited for applications in optical communication and optical interconnection network.

  18. Temperature calculations of heat loads in rotating target wheels exposed to high beam currents

    NASA Astrophysics Data System (ADS)

    Greene, John P.; Gabor, Rachel; Neubauer, Janelle

    2001-07-01

    In heavy-ion physics, high beam currents can eventually melt or destroy the target. Tightly focused beams on stationary targets of modest melting point will exhibit short lifetimes. Defocused or "wobbled" beams are employed to enhance target survival. Rotating targets using large diameter wheels can help overcome target melting and allow for higher beam currents to be used in experiments. The purpose of the calculations in this work is to try and predict the safe maximum beam currents which produce heat loads below the melting point of the target material.

  19. Resistive wall heating due to image current on the beam chamber for a superconducting undulator.

    SciTech Connect

    Kim, S. H. )

    2012-03-27

    The image-current heating on the resistive beam chamber of a superconducting undulator (SCU) was calculated based on the normal and anomalous skin effects. Using the bulk resistivity of copper for the beam chamber, the heat loads were calculated for the residual resistivity ratios (RRRs) of unity at room temperature to 100 K at a cryogenic temperature as the reference. Then, using the resistivity of the specific aluminum alloy 6053-T5, which will be used for the SCU beam chamber, the heat loads were calculated. An electron beam stored in a storage ring induces an image current on the inner conducting wall, mainly within a skin depth, of the beam chamber. The image current, with opposite charge to the electron beam, travels along the chamber wall in the same direction as the electron beam. The average current in the storage ring consists of a number of bunches. When the pattern of the bunched beam is repeated according to the rf frequency, the beam current may be expressed in terms of a Fourier series. The time structure of the image current is assumed to be the same as that of the beam current. For a given resistivity of the chamber inner wall, the application ofthe normal or anomalous skin effect will depend on the harmonic numbers of the Fourier series of the beam current and the temperature of the chamber. For a round beam chamber with a ratius r, much larger than the beam size, one can assume that the image current density as well as the density square, may be uniform around the perimeter 2{pi}r. For the SCU beam chamber, which has a relatively narrow vertical gap compared to the width, the effective perimeter was estimated since the heat load should be proportional to the inverse of the perimeter.

  20. Controlling hollow relativistic electron beam orbits with an inductive current divider

    SciTech Connect

    Swanekamp, S. B.; Richardson, A. S.; Angus, J. R.; Cooperstein, G.; Hinshelwood, D. D.; Ottinger, P. F.; Rittersdorf, I. M.; Schumer, J. W.; Weber, B. V.; Zier, J. C.

    2015-02-06

    A passive method for controlling the trajectory of an intense, hollow electron beam is proposed using a vacuum structure that inductively splits the beam's return current. A central post carries a portion of the return current (I1), while the outer conductor carries the remainder (I2). An envelope equation appropriate for a hollow electron beam is derived and applied to the current divider. The force on the beam trajectory is shown to be proportional to (I2-I1), while the average force on the envelope (the beam width) is proportional to the beam current Ib = (I2 + I1). The values of I1 and I2 depend on the inductances in the return-current path geometries. Proper choice of the return-current geometries determines these inductances and offers control over the beam trajectory. As a result, solutions using realistic beam parameters show that, for appropriate choices of the return-current-path geometry, the inductive current divider can produce a beam that is both pinched and straightened so that it approaches a target at near-normal incidence with a beam diameter that is on the order of a few mm.

  1. Controlling hollow relativistic electron beam orbits with an inductive current divider

    DOE PAGES

    Swanekamp, S. B.; Richardson, A. S.; Angus, J. R.; ...

    2015-02-06

    A passive method for controlling the trajectory of an intense, hollow electron beam is proposed using a vacuum structure that inductively splits the beam's return current. A central post carries a portion of the return current (I1), while the outer conductor carries the remainder (I2). An envelope equation appropriate for a hollow electron beam is derived and applied to the current divider. The force on the beam trajectory is shown to be proportional to (I2-I1), while the average force on the envelope (the beam width) is proportional to the beam current Ib = (I2 + I1). The values of I1more » and I2 depend on the inductances in the return-current path geometries. Proper choice of the return-current geometries determines these inductances and offers control over the beam trajectory. As a result, solutions using realistic beam parameters show that, for appropriate choices of the return-current-path geometry, the inductive current divider can produce a beam that is both pinched and straightened so that it approaches a target at near-normal incidence with a beam diameter that is on the order of a few mm.« less

  2. Controlling hollow relativistic electron beam orbits with an inductive current divider

    SciTech Connect

    Swanekamp, S. B.; Richardson, A. S.; Angus, J. R.; Cooperstein, G.; Hinshelwood, D. D.; Ottinger, P. F.; Rittersdorf, I. M.; Schumer, J. W.; Weber, B. V.; Zier, J. C.

    2015-02-15

    A passive method for controlling the trajectory of an intense, hollow electron beam is proposed using a vacuum structure that inductively splits the beam's return current. A central post carries a portion of the return current (I{sub 1}), while the outer conductor carries the remainder (I{sub 2}). An envelope equation appropriate for a hollow electron beam is derived and applied to the current divider. The force on the beam trajectory is shown to be proportional to (I{sub 2}-I{sub 1}), while the average force on the envelope (the beam width) is proportional to the beam current I{sub b} = (I{sub 2} + I{sub 1}). The values of I{sub 1} and I{sub 2} depend on the inductances in the return-current path geometries. Proper choice of the return-current geometries determines these inductances and offers control over the beam trajectory. Solutions using realistic beam parameters show that, for appropriate choices of the return-current-path geometry, the inductive current divider can produce a beam that is both pinched and straightened so that it approaches a target at near-normal incidence with a beam diameter that is on the order of a few mm.

  3. microRNAs of parasites: current status and future perspectives

    Technology Transfer Automated Retrieval System (TEKTRAN)

    MicroRNAs (miRNAs) are a class of endogenous non-coding small RNAs regulating gene expression in eukaryotes at the post-transcriptional level. The complex life cycles of parasites may require the ability to respond to environmental and developmental signals through miRNA-mediated gene expression. Ov...

  4. Proton beam therapy in Japan: current and future status.

    PubMed

    Sakurai, Hideyuki; Ishikawa, Hitoshi; Okumura, Toshiyuki

    2016-10-01

    The number of patients treated by proton beam therapy in Japan since 2000 has increased; in 2016, 11 proton facilities were available to treat patients. Notably, proton beam therapy is very useful for pediatric cancer; since the pediatric radiation dose to normal tissues should be reduced as much as possible because of the effect of radiation on growth, intellectual development, endocrine organ function and secondary cancer development. Hepatocellular carcinoma is common in Asia, and most of the studies of proton beam therapy for liver cancer have been reported by Japanese investigators. Proton beam therapy is also a standard treatment for nasal and paranasal lesions and lesions at the base of the skull, because the radiation dose to critical organs such as the eyes, optic nerves and central nervous system can be reduced with proton beam therapy. For prostate cancer, comparative studies that address adverse effects, safety, patient quality of life and socioeconomic issues should be performed to determine the appropriate use of proton beam therapy for prostate cancer. Regarding new proton beam therapy applications, experience with proton beam therapy combined with chemotherapy is limited, although favorable outcomes have been recently reported for locally advanced lung cancer, esophageal cancer and pancreatic cancer. Therefore, 'chemoproton' therapy appears to be a very attractive field for further clinical investigations. In conclusion, there are cost issues and considerations regarding national insurance for the use of proton beam therapy in Japan. Further studies and discussions are needed to address the use of proton beam therapy for several types of cancers, and for maintaining the quality of life of patients while retaining a high cure rate.

  5. MicroRNA Detection: Current Technology and Research Strategies

    NASA Astrophysics Data System (ADS)

    Hunt, Eric A.; Broyles, David; Head, Trajen; Deo, Sapna K.

    2015-07-01

    The relatively new field of microRNA (miR) has experienced rapid growth in methodology associated with its detection and bioanalysis as well as with its role in -omics research, clinical diagnostics, and new therapeutic strategies. The breadth of this area of research and the seemingly exponential increase in number of publications on the subject can present scientists new to the field with a daunting amount of information to evaluate. This review aims to provide a collective overview of miR detection methods by relating conventional, established techniques [such as quantitative reverse transcription polymerase chain reaction (RT-qPCR), microarray, and Northern blotting (NB)] and relatively recent advancements [such as next-generation sequencing (NGS), highly sensitive biosensors, and computational prediction of microRNA/targets] to common miR research strategies. This should guide interested readers toward a more focused study of miR research and the surrounding technology.

  6. Particle-in-cell simulations of electron beam control using an inductive current divider

    SciTech Connect

    Swanekamp, S. B.; Angus, J. R.; Cooperstein, G.; Ottinger, P. F.; Richardson, A. S.; Schumer, J. W.; Weber, B. V.

    2015-11-18

    Kinetic, time-dependent, electromagnetic, particle-in-cell simulations of the inductive current divider are presented. The inductive current divider is a passive method for controlling the trajectory of an intense, hollow electron beam using a vacuum structure that inductively splits the beam’s return current. The current divider concept was proposed and studied theoretically in a previous publication [Phys. Plasmas 22, 023107 (2015)] A central post carries a portion of the return current (I1) while the outer conductor carries the remainder (I2) with the injected beam current given by Ib=I1+I2. The simulations are in agreement with the theory which predicts that the total force on the beam trajectory is proportional to (I2-I1) and the force on the beam envelope is proportional to Ib. For a fixed central post, the beam trajectory is controlled by varying the outer conductor radius which changes the inductance in the return-current path. The simulations show that the beam emittance is approximately constant as the beam propagates through the current divider to the target. As a result, independent control over both the current density and the beam angle at the target is possible by choosing the appropriate return-current geometry.

  7. Particle-in-cell simulations of electron beam control using an inductive current divider

    DOE PAGES

    Swanekamp, S. B.; Angus, J. R.; Cooperstein, G.; ...

    2015-11-18

    Kinetic, time-dependent, electromagnetic, particle-in-cell simulations of the inductive current divider are presented. The inductive current divider is a passive method for controlling the trajectory of an intense, hollow electron beam using a vacuum structure that inductively splits the beam’s return current. The current divider concept was proposed and studied theoretically in a previous publication [Phys. Plasmas 22, 023107 (2015)] A central post carries a portion of the return current (I1) while the outer conductor carries the remainder (I2) with the injected beam current given by Ib=I1+I2. The simulations are in agreement with the theory which predicts that the total forcemore » on the beam trajectory is proportional to (I2-I1) and the force on the beam envelope is proportional to Ib. For a fixed central post, the beam trajectory is controlled by varying the outer conductor radius which changes the inductance in the return-current path. The simulations show that the beam emittance is approximately constant as the beam propagates through the current divider to the target. As a result, independent control over both the current density and the beam angle at the target is possible by choosing the appropriate return-current geometry.« less

  8. Micro-particle manipulation by single beam acoustic tweezers based on hydrothermal PZT thick film

    PubMed Central

    Zhu, Benpeng; Xu, Jiong; Li, Ying; Wang, Tian; Xiong, Ke; Lee, Changyang; Yang, Xiaofei; Shiiba, Michihisa; Takeuchi, Shinichi; Zhou, Qifa; Shung, K. Kirk

    2016-01-01

    Single-beam acoustic tweezers (SBAT), used in laboratory-on-a-chip (LOC) device has promising implications for an individual micro-particle contactless manipulation. In this study, a freestanding hydrothermal PZT thick film with excellent piezoelectric property (d33 = 270pC/N and kt = 0.51) was employed for SBAT applications and a press-focusing technology was introduced. The obtained SBAT, acting at an operational frequency of 50MHz, a low f-number (∼0.9), demonstrated the capability to trap and manipulate a micro-particle sized 10μm in the distilled water. These results suggest that such a device has great potential as a manipulator for a wide range of biomedical and chemical science applications. PMID:27014504

  9. Micro-cone targets for producing high energy and low divergence particle beams

    DOEpatents

    Le Galloudec, Nathalie

    2013-09-10

    The present invention relates to micro-cone targets for producing high energy and low divergence particle beams. In one embodiment, the micro-cone target includes a substantially cone-shaped body including an outer surface, an inner surface, a generally flat and round, open-ended base, and a tip defining an apex. The cone-shaped body tapers along its length from the generally flat and round, open-ended base to the tip defining the apex. In addition, the outer surface and the inner surface connect the base to the tip, and the tip curves inwardly to define an outer surface that is concave, which is bounded by a rim formed at a juncture where the outer surface meets the tip.

  10. Design and initial tests of beam current monitoring systems for the APS transport lines

    SciTech Connect

    Wang, Xucheng

    1992-12-01

    The non-intercepting beam current monitoring systems suitable for a wide, range of beam parameters have been developed for the Advanced Photon Source (APS) low energy transport lines and high energy transport line. The positron or electron beam pulse in the transport lines wig have peak beam currents ranging from 8 mA to 29 A with pulse widths varying from 120 ps to 30 ns and pulse repetition rates from 2 Hz to 60 Hz. The peak beam current or total beam charge is measured with the fast or integrating current transformer, respectively, manufactured by Bergoz. In-house high speed beam signal processing electronics provide a DC level output proportional to the peak current or total charge for the digitizer input. The prototype systems were tested on the linacs which have beam pulse structures similar to that of the APS transport lines. This paper describes the design of beam signal processing electronics and grounding and shielding methods for current transformers. The results of the initial operations are presented. A short introduction on the preliminary design of current monitoring systems for the APS rings is also included.

  11. Design and initial tests of beam current monitoring systems for the APS transport lines

    SciTech Connect

    Wang, Xucheng.

    1992-01-01

    The non-intercepting beam current monitoring systems suitable for a wide, range of beam parameters have been developed for the Advanced Photon Source (APS) low energy transport lines and high energy transport line. The positron or electron beam pulse in the transport lines wig have peak beam currents ranging from 8 mA to 29 A with pulse widths varying from 120 ps to 30 ns and pulse repetition rates from 2 Hz to 60 Hz. The peak beam current or total beam charge is measured with the fast or integrating current transformer, respectively, manufactured by Bergoz. In-house high speed beam signal processing electronics provide a DC level output proportional to the peak current or total charge for the digitizer input. The prototype systems were tested on the linacs which have beam pulse structures similar to that of the APS transport lines. This paper describes the design of beam signal processing electronics and grounding and shielding methods for current transformers. The results of the initial operations are presented. A short introduction on the preliminary design of current monitoring systems for the APS rings is also included.

  12. High-pressure generation using double stage micro-paired diamond anvils shaped by focused ion beam

    SciTech Connect

    Sakai, Takeshi Ohfuji, Hiroaki; Yagi, Takehiko; Irifune, Tetsuo; Ohishi, Yasuo; Hirao, Naohisa; Suzuki, Yuya; Kuroda, Yasushi; Asakawa, Takayuki; Kanemura, Takashi

    2015-03-15

    Micron-sized diamond anvils with a 3 μm culet were successfully processed using a focused ion beam (FIB) system and the generation of high pressures was confirmed using the double stage diamond anvil cell technique. The difficulty of aligning two second-stage micro-anvils was solved via the paired micro-anvil method. Micro-manufacturing using a FIB system enables us to control anvil shape, process any materials, including nano-polycrystalline diamond and single crystal diamond, and assemble the sample exactly in a very small space between the second-stage anvils. This method is highly reproducible. High pressures over 300 GPa were achieved, and the pressure distribution around the micro-anvil culet was evaluated by using a well-focused synchrotron micro-X-ray beam.

  13. Direct Measurement of Electron Beam Induced Currents in p-type Silicon

    SciTech Connect

    Han, M.G.; Zhu, Y.; Sasaki, K.; Kato, T.; Fisher, C.A.J.; Hirayama, T.

    2010-08-01

    A new method for measuring electron beam induced currents (EBICs) in p-type silicon using a transmission electron microscope (TEM) with a high-precision tungsten probe is presented. Current-voltage (I-V) curves obtained under various electron-beam illumination conditions are found to depend strongly on the current density of the incoming electron beam and the relative distance of the beam from the point of probe contact, consistent with a buildup of excess electrons around the contact. This setup provides a new experimental approach for studying minority carrier transport in semiconductors on the nanometer scale.

  14. Vibrations of micro-beams actuated by an electric field via Parameter Expansion Method

    NASA Astrophysics Data System (ADS)

    Sedighi, Hamid M.; Shirazi, Kourosh H.

    2013-04-01

    This paper presents a new asymptotic procedure to predict the nonlinear vibrational behavior of micro-beams pre-deformed by an electric field. The nonlinear equation of motion includes both even and odd nonlinearities. A powerful analytical method called Parameter Expansion Method (PEM) is employed to obtain the approximated solution and frequency-amplitude relationship. It is demonstrated that the first two terms in series expansions are sufficient to produce an acceptable solution of mentioned system. The obtained results from numerical methods verify the soundness of the analytical procedure. Finally, the influences of basic parameters on pull-in instability and natural frequency are investigated.

  15. Intense, brilliant micro γ-beams in nuclear physics and applications

    NASA Astrophysics Data System (ADS)

    Habs, D.; Gasilov, S.; Lang, C.; Thirolf, P. G.; Jentschel, M.; Diehl, R.; Schroer, C.; Barty, C. P. J.; Zamfir, N. V.

    2011-06-01

    900, we can obtain small spots for each of the beamlets. While focusing the beamlets to a much smaller spot size, we can bend them effectively with micro wedges to e.g. parallel beamlets. We can monochromatize these γ beamlets within the rocking curve of a common Laue crystal, using an additional angle selection by a collimator to reach a strongly reduced band width of 10-4 - 10-6. We propose the use of a further lens/wedge arrays or Bragg reflection to superimpose the beamlets to a very small total γ beam spot. Many experiments gain much from the high beam resolution and the smaller focal spot. This new γ optics requires high resolution diagnostics, where we want to optimize the focusing, using very thin target wires of a specific nuclear resonance fluorescence (NRF) isotope to monitor the focusing for the resonance energy. With such beams we can explore new nuclear physics of higher excited states with larger level densities. New phenomena, like the transition from chaotic to regular nuclear motion, weakly-bound halo states or states decaying by tunneling can be studied. The higher level density also allows to probe parity violating nuclear forces more sensitively. This γ optics improves many applications, like a more brilliant positron source, a more brilliant neutron source, higher specific activity of medical radioisotopes or NRF micro-imaging.

  16. Adaptive laser beam forming for laser shock micro-forming for 3D MEMS devices fabrication

    NASA Astrophysics Data System (ADS)

    Zou, Ran; Wang, Shuliang; Wang, Mohan; Li, Shuo; Huang, Sheng; Lin, Yankun; Chen, Kevin P.

    2016-07-01

    Laser shock micro-forming is a non-thermal laser forming method that use laser-induced shockwave to modify surface properties and to adjust shapes and geometry of work pieces. In this paper, we present an adaptive optical technique to engineer spatial profiles of the laser beam to exert precision control on the laser shock forming process for free-standing MEMS structures. Using a spatial light modulator, on-target laser energy profiles are engineered to control shape, size, and deformation magnitude, which has led to significant improvement of the laser shock processing outcome at micrometer scales. The results presented in this paper show that the adaptive-optics laser beam forming is an effective method to improve both quality and throughput of the laser forming process at micrometer scales.

  17. Limitations to laser machining of silicon using femtosecond micro-Bessel beams in the infrared

    SciTech Connect

    Grojo, David Mouskeftaras, Alexandros; Delaporte, Philippe; Lei, Shuting

    2015-04-21

    We produce and characterize high-angle femtosecond Bessel beams at 1300-nm wavelength leading to nonlinearly ionized plasma micro-channels in both glass and silicon. With microjoule pulse energy, we demonstrate controlled through-modifications in 150-μm glass substrates. In silicon, strong two-photon absorption leads to larger damages at the front surface but also a clamping of the intensity inside the bulk at a level of ≈4 × 10{sup 11 }W cm{sup −2} which is below the threshold for volume and rear surface modification. We show that the intensity clamping is associated with a strong degradation of the Bessel-like profile. The observations highlight that the inherent limitation to ultrafast energy deposition inside semiconductors with Gaussian focusing [Mouskeftaras et al., Appl. Phys. Lett. 105, 191103 (2014)] applies also for high-angle Bessel beams.

  18. Measurement of back-scattered radiation from micro multileaf collimator into the beam monitor chamber from a dual energy linear accelerator

    PubMed Central

    Muralidhar, K. R.; Murthy, P. Narayana; Sresty, N. V. N. M.; Dixit, Pramod Kumar; Kumar, Rajneesh; Raju, A. K.

    2007-01-01

    Measurements designed to find the collimator backscatter into the beam monitor chamber from Micro Multileaf collimator of 6 MV photon beams of the Siemens Primus linear accelerator were made with the help of dose rate feedback control. The photons and electrons backscattered from the upper and lower secondary collimator jaws give rise to a significant increase in the ion charge measured by monitor chamber. This increase varies between the different accelerators. The output measurements were carried out in air at the isocenter. The effect of collimator backscatter was investigated by measuring the pulse width, number of beam pulses per monitor unit, monitor unit rate and dose for different mMLC openings. These measurements were made with and without dose rate feedback control, i.e., with constant electron beam current in the accelerator. Monitor unit rate (MU/min) was almost constant for all field sizes. The maximum variation between the open and the closed feedback control circuits was 2.5%. There was no difference in pulse width and negligible difference in pulse frequency. Maximum value of backscattered radiation from the micro Multileaf collimator into the beam monitor chamber was found to be 0.5%. PMID:21157537

  19. A NEW DIFFERENTIAL AND ERRANT BEAM CURRENT MONITOR FOR THE SNS* ACCELERATOR

    SciTech Connect

    Blokland, Willem; Peters, Charles C

    2013-01-01

    A new Differential and errant Beam Current Monitor (DBCM) is being implemented for both the Spallation Neutron Source's Medium Energy Beam Transport (MEBT) and the Super Conducting Linac (SCL) accelerator sections. These new current monitors will abort the beam when the difference between two toroidal pickups exceeds a threshold. The MEBT DBCM will protect the MEBT chopper target, while the SCL DBCM will abort beam to minimize fast beam losses in the SCL cavities. The new DBCM will also record instances of errant beam, such as beam dropouts, to assist in further optimization of the SNS Accelerator. A software Errant Beam Monitor was implemented on the regular BCM hardware to study errant beam pulses. The new system will take over this functionality and will also be able to abort beam on pulse-to-pulse variations. Because the system is based on the FlexRIO hardware and programmed in LabVIEW FPGA, it will be able to abort beam in about 5 us. This paper describes the development, implementation, and initial test results of the DBCM, as well as errant beam examples.

  20. Increasing Extracted Beam Current Density in Ion Thrusters through Plasma Potential Modification

    NASA Astrophysics Data System (ADS)

    Arthur, Neil; Foster, John

    2015-09-01

    A gridded ion thruster's maximum extractable beam current is determined by the space charge limit. The classical formulation does not take into account finite ion drift into the acceleration gap. It can be shown that extractable beam current can be increased beyond the conventional Child-Langmuir law if the ions enter the gap at a finite drift speed. In this work, ion drift in a 10 cm thruster is varied by adjusting the plasma potential relative to the potential at the extraction plane. Internal plasma potential variations are achieved using a novel approach involving biasing the magnetic cusps. Ion flow variations are assessed using simulated beam extraction in conjunction with a retarding potential analyzer. Ion beam current density changes at a given total beam voltage in full beam extraction tests are characterized as a function of induced ion drift velocity as well.

  1. Generation of Ramped Current Profiles in Relativistic Electron Beams Using Wakefields in Dielectric Structures.

    PubMed

    Andonian, G; Barber, S; O'Shea, F H; Fedurin, M; Kusche, K; Swinson, C; Rosenzweig, J B

    2017-02-03

    Temporal pulse tailoring of charged-particle beams is essential to optimize efficiency in collinear wakefield acceleration schemes. In this Letter, we demonstrate a novel phase space manipulation method that employs a beam wakefield interaction in a dielectric structure, followed by bunch compression in a permanent magnet chicane, to longitudinally tailor the pulse shape of an electron beam. This compact, passive, approach was used to generate a nearly linearly ramped current profile in a relativistic electron beam experiment carried out at the Brookhaven National Laboratory Accelerator Test Facility. Here, we report on these experimental results including beam and wakefield diagnostics and pulse profile reconstruction techniques.

  2. Generation of Ramped Current Profiles in Relativistic Electron Beams Using Wakefields in Dielectric Structures

    NASA Astrophysics Data System (ADS)

    Andonian, G.; Barber, S.; O'Shea, F. H.; Fedurin, M.; Kusche, K.; Swinson, C.; Rosenzweig, J. B.

    2017-02-01

    Temporal pulse tailoring of charged-particle beams is essential to optimize efficiency in collinear wakefield acceleration schemes. In this Letter, we demonstrate a novel phase space manipulation method that employs a beam wakefield interaction in a dielectric structure, followed by bunch compression in a permanent magnet chicane, to longitudinally tailor the pulse shape of an electron beam. This compact, passive, approach was used to generate a nearly linearly ramped current profile in a relativistic electron beam experiment carried out at the Brookhaven National Laboratory Accelerator Test Facility. Here, we report on these experimental results including beam and wakefield diagnostics and pulse profile reconstruction techniques.

  3. Acceleration and stability of a high-current ion beam in induction fields

    NASA Astrophysics Data System (ADS)

    Karas', V. I.; Manuilenko, O. V.; Tarakanov, V. P.; Federovskaya, O. V.

    2013-03-01

    A one-dimensional nonlinear analytic theory of the filamentation instability of a high-current ion beam is formulated. The results of 2.5-dimensional numerical particle-in-cell simulations of acceleration and stability of an annular compensated ion beam (CIB) in a linear induction particle accelerator are presented. It is shown that additional transverse injection of electron beams in magnetically insulated gaps (cusps) improves the quality of the ion-beam distribution function and provides uniform beam acceleration along the accelerator. The CIB filamentation instability in both the presence and the absence of an external magnetic field is considered.

  4. Acceleration and stability of a high-current ion beam in induction fields

    SciTech Connect

    Karas', V. I.; Manuilenko, O. V.; Tarakanov, V. P.; Federovskaya, O. V.

    2013-03-15

    A one-dimensional nonlinear analytic theory of the filamentation instability of a high-current ion beam is formulated. The results of 2.5-dimensional numerical particle-in-cell simulations of acceleration and stability of an annular compensated ion beam (CIB) in a linear induction particle accelerator are presented. It is shown that additional transverse injection of electron beams in magnetically insulated gaps (cusps) improves the quality of the ion-beam distribution function and provides uniform beam acceleration along the accelerator. The CIB filamentation instability in both the presence and the absence of an external magnetic field is considered.

  5. A new method of rapid power measurement for MW-scale high-current particle beams

    NASA Astrophysics Data System (ADS)

    Xu, Yongjian; Hu, Chundong; Xie, Yuanlai; Liu, Zhimin; Xie, Yahong; Liu, Sheng; Liang, Lizheng; Jiang, Caichao; Sheng, Peng; Yu, Ling

    2015-09-01

    MW-scale high current particle beams are widely applied for plasma heating in the magnetic confinement fusion devices, in which beam power is an important indicator for efficient heating. Generally, power measurement of MW-scale high current particle beam adopts water flow calorimetry (WFC). Limited by the principles of WFC, the beam power given by WFC is an averaged value. In this article a new method of beam power for MW-scale high-current particle beams is introduced: (1) the temperature data of thermocouples embedded in the beam stopping elements were obtained using high data acquire system, (2) the surface heat flux of the beam stopping elements are calculated using heat transfer, (3) the relationships between positions and heat flux were acquired using numerical simulation, (4) the real-time power deposited on the beam stopping elements can be calculated using surface integral. The principle of measurement was described in detail and applied to the EAST neutral beam injector for demonstration. The result is compared with that measured by WFC. Comparison of the results shows good accuracy and applicability of this measuring method.

  6. Nonlinear Charge and Current Neutralization of an Ion Beam Pulse in a Pre-formed Plasma

    SciTech Connect

    Igor D. Kaganovich; Gennady Shvets; Edward Startsev; Ronald C. Davidson

    2001-01-30

    The propagation of a high-current finite-length ion beam in a cold pre-formed plasma is investigated. The outcome of the calculation is the quantitative prediction of the degree of charge and current neutralization of the ion beam pulse by the background plasma. The electric magnetic fields generated by the ion beam are studied analytically for the nonlinear case where the plasma density is comparable in size with the beam density. Particle-in-cell simulations and fluid calculations of current and charge neutralization have been performed for parameters relevant to heavy ion fusion assuming long, dense beams with el >> V(subscript b)/omega(subscript b), where V(subscript b) is the beam velocity and omega subscript b is the electron plasma frequency evaluated with the ion beam density. An important conclusion is that for long, nonrelativistic ion beams, charge neutralization is, for all practical purposes, complete even for very tenuous background plasmas. As a result, the self-magnetic force dominates the electric force and the beam ions are always pinched during beam propagation in a background plasma.

  7. Twin-beam real-time position estimation of micro-objects in 3D

    NASA Astrophysics Data System (ADS)

    Gurtner, Martin; Zemánek, Jiří

    2016-12-01

    Various optical methods for measuring positions of micro-objects in 3D have been reported in the literature. Nevertheless, the majority of them are not suitable for real-time operation, which is needed, for example, for feedback position control. In this paper, we present a method for real-time estimation of the position of micro-objects in 3D1; the method is based on twin-beam illumination and requires only a very simple hardware setup whose essential part is a standard image sensor without any lens. The performance of the proposed method is tested during a micro-manipulation task in which the estimated position served as feedback for the controller. The experiments show that the estimate is accurate to within  ∼3 μm in the lateral position and  ∼7 μm in the axial distance with the refresh rate of 10 Hz. Although the experiments are done using spherical objects, the presented method could be modified to handle non-spherical objects as well.

  8. Modeling and control of piezoelectric cantilever beam micro-mirror and micro-laser arrays to reduce image banding in electrophotographic processes

    NASA Astrophysics Data System (ADS)

    Cheng, Hung-Ming; Ewe, Michael T. S.; T-C Chiu, George; Bashir, Rashid

    2001-09-01

    This paper present a theoretical evaluation of the application of microelectromechanical technology to reduce banding artifacts in electrophotographic printing systems. The proposed system would consist of arrays of micro-mirrors and micro-lasers replacing conventional laser printing mechanisms. Several advantages of the new system include faster printing speeds, elimination of synchronization problems, improved image quality and lower production costs. Each micro-mirror can be a surface micro-machined piezoelectric cantilever beam with a reflective surface. An analytical model for the cantilever beam describing the dynamic relationship between scan line deflection and the applied voltage is derived. Using a closed-loop feedback control strategy, the effectiveness of the micro-mirror arrays in reducing banding was theoretically evaluated. Calculations show that each micro-mirror should be capable of deflecting the scan line a distance of 50 µm or approximately one 600 dots per inch (dpi) pixel by only using a 2 V voltage potential. Using an actual measured line spacing sequence, the operation of the system was simulated. The results demonstrated good tracking and significant reduction of the low-frequency banding components. Emulated images showed significant reduction in banding for a typical 600 dpi print resolution.

  9. Performance of Current-Mode Ion Chambers as Beam Monitors in a Pulsed Cold Neutron Beam for the NPDGamma experiment

    NASA Astrophysics Data System (ADS)

    Gillis, R. Chad

    2006-10-01

    The NPDGamma collaboration has built and commissioned an apparatus to measure the parity-violating gamma asymmetry A in the low energy np capture process n+p->d+ γ. The asymmetry in question is a 10-8 correlation between the spin of the incident (polarized) neutron and the outgoing 2.2 MeV gamma ray. A set of purpose-built, 3He-filled ionization chambers read out in current mode is used to monitor the incident neutron flux, the beam polarization, and the transmission of the liquid para-hydrogen target during the NPDGamma measurements. As will be described in the talk, these beam monitors are simple, reliable, low-noise detectors that have performed excellently for NPDGamma. We have verified that the beam monitor signals can be interpreted to reproduce the known time-of-flight dependence of beam flux from the LANSCE pulsed cold neutron source, and that the neutron beam polarization can be measured at the 2% level from direct measurements of the transmission of the beam through the beam polarizer.

  10. Diagnostics and electron-optics of a high current electron beam in the TANDEM free electron laser - status report

    SciTech Connect

    Arensburg, A.; Avramovich, A.; Chairman, D.

    1995-12-31

    In the construction of the Israeli TANDEM FEL the major task is to develop a high quality electron optic system. The goal is to focus the e-beam to a minimal radius (1 mm) in the interaction region (the wiggler). Furthermore, good focusing throughout the accelerator is essential in order to achieve high transport efficiency avoiding discharge and voltage drop of the high voltage terminal. We have completed the electron optical design and component procurement, including 8 quadrupole lenses 4 steering coils and an electrostatic control system. All are being assembled into the high voltage terminal and controlled by a fiber optic link. Diagnostic means based on fluorescent screens and compact CCD camera cards placed at the HV terminal and at the end of the e-gun injector have been developed. We report first measurements of the beam emittance at the entrance to the Tandem accelerator tube using the {open_quote}pepper pot{close_quote} technique. The experiment consists of passing the 0.5 Amp beam through a thin plate which is perforated with an army of 0.5 mm holes. The spots produced on a fluorescent screen placed 90 cm from the pepper pot were recorded with a CCD camera and a frame grabber. The measured normalized emittance is lower than 10{pi} mm mR which is quite close to the technical limit of dispenser cathode e-guns of the kind we have. Recent results of the measured transport efficiency and the diagnostics of the high current (1A, 1.5MV) electron-optical system will be reported.

  11. The INFN Micro-Si experiment: A silicon microdosimeter for assessing radiation quality of hadrontherapy beams

    NASA Astrophysics Data System (ADS)

    Agosteo, S.; Dal Corso, F.; Fazzi, A.; Gonella, F.; Introini, M. V.; Lippi, I.; Lorenzoli, M.; Pegoraro, M.; Pola, A.; Varoli, V.; Zotto, P.

    2013-07-01

    The MICRO-SI experiment, funded by INFN from 2008 up to 2010, aimed at developing a silicon microdosimeter capable of responding to neutrons and to hadron-therapy beams down to a few keV μm-1. The main goals which were achieved in the framework of this experiment are described in details. The detector, designed and fabricated by exploiting the monolithic telescope technology, demonstrated to provide charge confinement inside the micrometric sensitive volume, thus minimizing the field-funnelling effect. An innovative segmented telescope device was developed in order to have a silicon detector offering sensitive volume dimensions similar to those which can be simulated by a tissue-equivalent proportional counter (TEPC). The response of the segmented device to hadron beams was characterized with clinical protons and with 62 AMeV carbon ions at the INFN-Laboratori Nazionali del Sud (Catania, Italy). Irradiations with mono-energetic neutrons at the INFN-Laboratori Nazionali di Legnaro (Legnaro, Italy) were also performed. The agreement with the spectra measured with a TEPC is very satisfactory and gives confidence on the application of such a silicon device to assess the quality of hadrontherapy beams.

  12. The MICRO-BOSS scheduling system: Current status and future efforts

    NASA Technical Reports Server (NTRS)

    Sadeh, Norman M.

    1993-01-01

    In this paper, a micro-opportunistic approach to factory scheduling was described that closely monitors the evolution of bottlenecks during the construction of the schedule, and continuously redirects search towards the bottleneck that appears to be most critical. This approach differs from earlier opportunistic approaches, as it does not require scheduling large resource subproblems or large job subproblems before revising the current scheduling strategy. This micro-opportunistic approach was implemented in the context of the MICRO-BOSS factory scheduling system. A study comparing MICRO-BOSS against a macro-opportunistic scheduler suggests that the additional flexibility of the micro-opportunistic approach to scheduling generally yields important reductions in both tardiness and inventory.

  13. Cone beam CT in orthodontics: the current picture.

    PubMed

    Makdissi, Jimmy

    2013-03-01

    The introduction of cone beam computed tomography (CBCT) technology to dentistry and orthodontics revolutionized the diagnosis, treatment and monitoring of orthodontic patients. This review article discusses the use of CBCT in diagnosis and treatment planning in orthodontics. The steps required to install and operate a CBCT facility within the orthodontic practice as well as the challenges are highlighted. The available guidelines in relation to the clinical applications of CBCT in orthodontics are explored.

  14. Studies in High Current Beam Propagation at Reduced Pressures.

    DTIC Science & Technology

    1985-01-31

    43 3.2.2 Beam-Driven Chemistry in the Low-Density Regime..... 44 3.2.3 Non-Local, Non-Ohmic Conductivity Model ............. 45... chemistry processes (especially recombina- tion), and the role of radiative cooling in determining the onset of Spitzer conduction. Progress in...represent the cynamics of the two lower-energy groups, and a detailed air- chemistry reaction scheme also modifies the population of the low-energy group

  15. Deflection by the image current and charges of a beam scraper

    SciTech Connect

    Bane, K.L.F.; Morton, P.L.

    1986-05-01

    Scrapers are often used in storage rings and accelerators to clean the transverse profile of the beam. When the beam is not exactly midway between the jaws of the scraper the transverse electric and magnetic fields produced by the image charges and currents are asymmetric. For a relativistic beam traveling through a longitudinally uniform tube with infinitely conducting walls the transverse force from the electric field is canceled by the transverse force from the magnetic field. When an off-center particle bunch passes by a longitudinal discontinuity in the beam tube the transverse force from the electric field are no longer cancelled by the transverse force from the magnetic field and particles in the bunch experience a transverse momentum kick which is independent of energy. It is shown that scrapers that pass close by high peak current beams can significantly degrade the beam emittance. A circular scraper was chosen for computer simulation. (LEW)

  16. Transport and Measurements of High-Current Electron Beams from X pinches

    SciTech Connect

    Agafonov, Alexey V.; Mingaleev, Albert R.; Romanova, Vera M.; Tarakanov, Vladimir P.; Shelkovenko, Tatiana A.; Pikuz, Sergey A.; Blesener, Isaac C.; Kusse, Bruce R.; Hammer, David A.

    2009-01-21

    Generation of electron beams is an unavoidable property of X-pinches and other pulsed-power-driven pinches of different geometry. Some issues concerning high-current electron beam transport from the X pinch to the diagnostic system and measurements of the beam current by Faraday cups with different geometry's are discussed. Of particular interest is the partially neutralized nature of the beam propagating from the X-pinch to a diagnostic system. Two scenarios of electron beam propagation from X-pinch to Faraday cup are analyzed by means of computer simulation using the PIC-code KARAT. The first is longitudinal neutralization by ions extracted from plasma at an output window of the X-pinch diode; the second is the beam transport through a plasma background between the diode and a diagnostic system.

  17. Micro-gravity: current distributions creating a uniform force field

    NASA Astrophysics Data System (ADS)

    Vincent-Viry, O.; Mailfert, A.; Colteu, A.; Dael, A.; Gourdin, C.; Quettier, L.

    2001-02-01

    This paper presents two structures of superconducting coils able to give satisfactory solutions to the problem of generation of uniform field of high magnetic forces. The first structure is modeled by the use of purely surface current densities, whereas the second one can be described with volume current densities. Both of these structures proceed from the study of a particular expression of the complex magnetic potential introduced for structures with two-dimensional geometry. This work is carried out in a research collaboration between the GREEN and the DSM-DAPNIA department of the CEA Saclay.

  18. Surface modification of structural materials by low-energy high-current pulsed electron beam treatment

    SciTech Connect

    Panin, A. V. E-mail: kms@ms.tsc.ru; Kazachenok, M. S. E-mail: kms@ms.tsc.ru; Sinyakova, E. A.; Borodovitsina, O. M.; Ivanov, Yu. F.; Leontieva-Smirnova, M. V.

    2014-11-14

    Microstructure formation in surface layers of pure titanium and ferritic-martensitic steel subjected to electron beam treatment is studied. It is shown that low energy high-current pulsed electron beam irradiation leads to the martensite structure within the surface layer of pure titanium. Contrary, the columnar ferrite grains grow during solidification of ferritic-martensitic steel. The effect of electron beam energy density on the surface morphology and microstructure of the irradiated metals is demonstrated.

  19. The MICRO-BOSS scheduling system: Current status and future efforts

    NASA Technical Reports Server (NTRS)

    Sadeh, Norman M.

    1992-01-01

    In this paper, a micro-opportunistic approach to factory scheduling was described that closely monitors the evolution of bottlenecks during the construction of the schedule and continuously redirects search towards the bottleneck that appears to be most critical. This approach differs from earlier opportunistic approaches, as it does not require scheduling large resource subproblems or large job subproblems before revising the current scheduling strategy. This micro-opportunistic approach was implemented in the context of the MICRO-BOSS factory scheduling system. A study comparing MICRO-BOSS against a macro-opportunistic scheduler suggests that the additional flexibility of the micro-opportunistic approach to scheduling generally yields important reductions in both tardiness and inventory. Current research efforts include: adaptation of MICRO-BOSS to deal with sequence-dependent setups and development of micro-opportunistic reactive scheduling techniques that will enable the system to patch the schedule in the presence of contingencies such as machine breakdowns, raw materials arriving late, job cancellations, etc.

  20. A 128-channel picoammeter system and its application on charged particle beam current distribution measurements

    SciTech Connect

    Yu, Deyang Liu, Junliang; Xue, Yingli; Zhang, Mingwu; Cai, Xiaohong; Hu, Jianjun; Dong, Jinmei; Li, Xin

    2015-11-15

    A 128-channel picoammeter system is constructed based on instrumentation amplifiers. Taking advantage of a high electric potential and narrow bandwidth in DC energetic charged beam measurements, a current resolution better than 5 fA can be achieved. Two sets of 128-channel strip electrodes are implemented on printed circuit boards and are employed for ion and electron beam current distribution measurements. Tests with 60 keV O{sup 3+} ions and 2 keV electrons show that it can provide exact boundaries when a positive charged particle beam current distribution is measured.

  1. Effects of beam-driven poloidal rotation on the neoclassical bootstrap current

    SciTech Connect

    Lin-Liu, Y.R.; Hinton, F.L.

    1996-12-31

    Unbalanced neutral beam injection drives toroidal and poloidal rotations in a tokamak plasma. The beam toroidal momentum input drives the toroidal rotation, and the parallel friction between the thermal ions and fast ions induces the poloidal rotation. A theory of the beam-driven poloidal rotation and its effects on energy transport was given recently by Hinton and Kim. In this work, we extend their considerations to the effects on the neoclassical bootstrap current. For parameters of interest in present neutral beam heated tokamaks, the magnitude of the beam-driven poloidal rotation can be significantly larger than that of the standard neoclassical value due to the ion temperature gradient. The presence of this driven poloidal rotation will manifest itself in modification of the neoclassical bootstrap current. In the case of coinjection, the driven poloidal rotation is in the opposite direction to the rotation driven by the temperature gradient, therefore it enhances the bootstrap current. In comparison with the standard theoretical predictions of the neutral beam-driven current, that enhancement in the bootstrap current varies with the beam and plasma parameters. A calculation of the parallel transport coefficients associated with the driven poloidal flow in finite-aspect ratio tokamaks will be presented. Experimental conditions for observing the enhancement in bootstrap current will be discussed.

  2. Surface-Charge-Based Micro-Models--A Solid Foundation for Learning about Direct Current Circuits

    ERIC Educational Resources Information Center

    Hirvonen, P. E.

    2007-01-01

    This study explores how the use of a surface-charge-based instructional approach affects introductory university level students' understanding of direct current (dc) circuits. The introduced teaching intervention includes electrostatics, surface-charge-based micro-models that explain the existence of an electric field inside the current-carrying…

  3. Physiologically gated micro-beam radiation therapy using electronically controlled field emission x-ray source array

    NASA Astrophysics Data System (ADS)

    Chtcheprov, Pavel; Hadsell, Michael; Burk, Laurel; Ger, Rachel; Zhang, Lei; Yuan, Hong; Lee, Yueh Z.; Chang, Sha; Lu, Jianping; Zhou, Otto

    2013-03-01

    Micro-beam radiation therapy (MRT) uses parallel planes of high dose narrow (10-100 um in width) radiation beams separated by a fraction of a millimeter to treat cancerous tumors. This experimental therapy method based on synchrotron radiation has been shown to spare normal tissue at up to 1000Gy of entrance dose while still being effective in tumor eradication and extending the lifetime of tumor-bearing small animal models. Motion during the treatment can result in significant movement of micro beam positions resulting in broader beam width and lower peak to valley dose ratio (PVDR), and thus can reduce the effectiveness of the MRT. Recently we have developed the first bench-top image guided MRT system for small animal treatment using a high powered carbon nanotube (CNT) x-ray source array. The CNT field emission x-ray source can be electronically synchronized to an external triggering signal to enable physiologically gated firing of x-ray radiation to minimize motion blurring. Here we report the results of phantom study of respiratory gated MRT. A simulation of mouse breathing was performed using a servo motor. Preliminary results show that without gating the micro beam full width at tenth maximum (FWTM) can increase by 70% and PVDR can decrease up to 50%. But with proper gating, both the beam width and PVDR changes can be negligible. Future experiments will involve irradiation of mouse models and comparing histology stains between the controls and the gated irradiation.

  4. Anodal current intensities above 40 microA interfere with current-induced axon-reflex vasodilatation in human skin.

    PubMed

    Tartas, M; Durand, S; Koïtka, A; Bouyé, P; Saumet, J L; Abraham, P

    2004-01-01

    When using iontophoresis, the 'non-specific' vasodilatation (NSV) that is observed as a result of C-fibre excitation is generally attributed to the local accumulation of protons under the anode. NSV following prolonged 100-microA anodal current application only appears after the current is stopped. Break excitation alone does not explain the delayed onset of this vasodilatation. We hypothesised that this delay could result from an anodal block and thus, that a minimal intensity would be required to achieve hyperpolarisation of primary afferent fibres (mainly C-fibres). Using laser Doppler flowmetry, cutaneous blood flow was recorded in the forearms of 8 healthy volunteers 2 min before current application, during the application and 20 min after stopping the monopolar anodal current. In protocol 1, after 2.5 min of current application at an intensity of 100 microA, the intensity was abruptly decreased to 0-80 microA for a second 2.5-min period. The onset of vasodilatation was only delayed at intensities >30 microA during this second period. In protocol 2, re-application of the current after a 50-second interruption (expected to allow for the occurrence of an axon reflex) did not interfere with the onset of vasodilatation. Thus: (1) the minimal intensity interfering with the axon reflex is far lower than that reported for C-fibre blockade in isolated nerves; (2) the results suggest that current application does not directly interfere with the vasodilator mechanisms induced by the axon reflex at the level of smooth muscle cells.

  5. High-current fast electron beam propagation in a dielectric target.

    PubMed

    Klimo, Ondrej; Tikhonchuk, V T; Debayle, A

    2007-01-01

    Recent experiments demonstrate an efficient transformation of high intensity laser pulse into a relativistic electron beam with a very high current density exceeding 10(12) A cm(-2). The propagation of such a beam inside the target is possible if its current is neutralized. This phenomenon is not well understood, especially in dielectric targets. In this paper, we study the propagation of high current density electron beam in a plastic target using a particle-in-cell simulation code. The code includes both ionization of the plastic and collisions of newborn electrons. The numerical results are compared with a relatively simple analytical model and a reasonable agreement is found. The temporal evolution of the beam velocity distribution, the spatial density profile, and the propagation velocity of the ionization front are analyzed and their dependencies on the beam density and energy are discussed. The beam energy losses are mainly due to the target ionization induced by the self-generated electric field and the return current. For the highest beam density, a two-stream instability is observed to develop in the plasma behind the ionization front and it contributes to the beam energy losses.

  6. Accurate Coregistration between Ultra-High-Resolution Micro-SPECT and Circular Cone-Beam Micro-CT Scanners.

    PubMed

    Ji, Changguo; van der Have, Frans; Gratama van Andel, Hugo; Ramakers, Ruud; Beekman, Freek

    2010-01-01

    Introduction. Spatially registering SPECT with CT makes it possible to anatomically localize SPECT tracers. In this study, an accurate method for the coregistration of ultra-high-resolution SPECT volumes and multiple cone-beam CT volumes is developed and validated, which does not require markers during animal scanning. Methods. Transferable animal beds were developed with an accurate mounting interface. Simple calibration phantoms make it possible to obtain both the spatial transformation matrix for stitching multiple CT scans of different parts of the animal and to register SPECT and CT. The spatial transformation for image coregistration is calculated once using Horn's matching algorithm. Animal images can then be coregistered without using markers. Results. For mouse-sized objects, average coregistration errors between SPECT and CT in X, Y, and Z directions are within 0.04 mm, 0.10 mm, and 0.19 mm, respectively. For rat-sized objects, these numbers are 0.22 mm, 0.14 mm, and 0.28 mm. Average 3D coregistration errors were within 0.24 mm and 0.42 mm for mouse and rat imaging, respectively. Conclusion. Extending the field-of-view of cone-beam CT by stitching is improved by prior registration of the CT volumes. The accuracy of registration between SPECT and CT is typically better than the image resolution of current ultra-high-resolution SPECT.

  7. Trapping of a micro-bubble by non-paraxial Gaussian beam: computation using the FDTD method.

    PubMed

    Sung, Seung-Yong; Lee, Yong-Gu

    2008-03-03

    Optical forces on a micro-bubble were computed using the Finite Difference Time Domain method. Non-paraxial Gaussian beam equation was used to represent the incident laser with high numerical aperture, common in optical tweezers. The electromagnetic field distribution around a micro-bubble was computed using FDTD method and the electromagnetic stress tensor on the surface of a micro-bubble was used to compute the optical forces. By the analysis of the computational results, interesting relations between the radius of the circular trapping ring and the corresponding stability of the trap were found.

  8. Fabrication of micro-array of Fresnel rings on Si by electron beam lithography and reactive ion etching

    NASA Astrophysics Data System (ADS)

    Chiromawa, Nura Liman; Ibrahim, Kamarulazizi

    2016-02-01

    Recently, micro-lenses have attracted more attention among optoelectronics device application developers. This paper presents the micro-array of Si-Fresnel rings fabricated by the electron beam lithography and reactive ion etching. Fresnel rings units containing 11 concentric rings were created on the PMMA layer with the outermost Fresnel ring, having an external diameter of 45.24 μm, and are located ≈200 μm away from each other. These structures can be copied as the micro-array of Fresnel lenses for optoelectronics device applications.

  9. Operating experience with high beam currents and transient beam loading in the SLC damping rings

    SciTech Connect

    Minty, M.G.; Akre, R.; Krejcik, P.; Siemann, R.H.

    1995-06-01

    During the 1994 SLC run the nominal operating intensity in the damping rings was raised from 3.5 {times} 10{sup 10} to greater than 4 {times} 10{sup 10} particles per bunch (ppb). Stricter regulation of rf system parameters was required to maintain stability of the rf system and particle beam. Improvements were made in the feedback loops which control the cavity amplitude and loading angles. Compensation for beam loading was also required to prevent klystron saturation during repetition rate changes. To minimize the effects of transient loading on the rf system, the gain of the direct rf feedback loop and the loading angles were optimized.

  10. Sparking limits, cavity loading, and beam breakup instability associated with high-current rf linacs

    SciTech Connect

    Faehl, R.J.; Lemons, D.S.; Thode, L.E.

    1982-01-01

    The limitations on high-current rf linacs due to gap sparking, cavity loading, and the beam breakup instability are studied. It appears possible to achieve cavity accelerating gradients as high as 35 MV/m without sparking. Furthermore, a linear analysis, as well as self-consistent particle simulations of a multipulsed 10 kA beam, indicated that only a negligible small fraction of energy is radiated into nonfundamental cavity modes. Finally, the beam breakup instability is analyzed and found to be able to magnify initial radial perturbations by a factor of no more than about 20 during the beam transit time through a 1 GeV accelerator.

  11. Laser Deposition of Polymer Micro- and Nanoassembly from Solution Using Focused Near-Infrared Laser Beam

    NASA Astrophysics Data System (ADS)

    Nabetani, Yu; Yoshikawa, Hiroyuki; Grimsdale, Andrew C.; Müllen, Klaus; Masuhara, Hiroshi

    2007-01-01

    We have demonstrated the laser deposition of polymer micro- and nanoassemblies from a solution onto a glass substrate. The size and shape of the deposited dot-like assembly can be controlled by the laser power (P) and the concentration of the solution (C). For an example, a nanoassembly of a π-conjugated polymer, whose width and height are 280 and 23 nm, respectively, is deposited at the conditions of C=1.0× 10-5 mg/ml and P=700 mW. This laser deposition can be attributed to the optical trapping and the surface deformation of the solution layer using a focused laser beam. It is also demonstrated that the molecular orientation in the assembly can be aligned in the direction of the laser polarization. The present laser deposition is applicable to the micropatterning of various polymers dissolved in an organic solvent.

  12. Modulation transfer function determination using the edge technique for cone-beam micro-CT

    NASA Astrophysics Data System (ADS)

    Rong, Junyan; Liu, Wenlei; Gao, Peng; Liao, Qimei; Lu, Hongbing

    2016-03-01

    Evaluating spatial resolution is an essential work for cone-beam computed tomography (CBCT) manufacturers, prototype designers or equipment users. To investigate the cross-sectional spatial resolution for different transaxial slices with CBCT, the slanted edge technique with a 3D slanted edge phantom are proposed and implemented on a prototype cone-beam micro-CT. Three transaxial slices with different cone angles are under investigation. An over-sampled edge response function (ERF) is firstly generated from the intensity of the slightly tiled air to plastic edge in each row of the transaxial reconstruction image. Then the oversampled ESF is binned and smoothed. The derivative of the binned and smoothed ERF gives the line spread function (LSF). At last the presampled modulation transfer function (MTF) is calculated by taking the modulus of the Fourier transform of the LSF. The spatial resolution is quantified with the spatial frequencies at 10% MTF level and full-width-half-maximum (FWHM) value. The spatial frequencies at 10% of MTFs are 3.1+/-0.08mm-1, 3.0+/-0.05mm-1, and 3.2+/-0.04mm-1 for the three transaxial slices at cone angles of 3.8°, 0°, and -3.8° respectively. The corresponding FWHMs are 252.8μm, 261.7μm and 253.6μm. Results indicate that cross-sectional spatial resolution has no much differences when transaxial slices being 3.8° away from z=0 plane for the prototype conebeam micro-CT.

  13. MicroRNA-181a-mediated downregulation of AC9 protein decreases intracellular cAMP level and inhibits ATRA-induced APL cell differentiation.

    PubMed

    Zhuang, L K; Xu, G P; Pan, X R; Lou, Y J; Zou, Q P; Xia, D; Yan, W W; Zhang, Y T; Jia, P M; Tong, J H

    2014-04-10

    AC9 is one of the adenylate cyclase (AC) isoforms, which catalyze the conversion of ATP to cAMP, an important second messenger. We previously found that the integration of cAMP/PKA pathway with nuclear receptor-mediated signaling was required during all-trans retinoic acid (ATRA)-induced maturation of acute promyelocytic leukemia (APL) cells. Here we showed that AC9 could affect intracellular cAMP level and enhance the trans-activity of retinoic acid receptor. Knockdown of AC9 in APL cell line NB4 could obviously inhibit ATRA-induced differentiation. We also demonstrated that miR-181a could decrease AC9 expression by targeting 3'UTR of AC9 mRNA, finally controlling the production of intracellular cAMP. The expression of miR-181a itself could be inhibited by CEBPα, probably accounting for the differential expression of miR-181a in NB4 and ATRA-resistant NB4-R1 cells. Moreover, we found that AC9 expression was relatively lower in newly diagnosed or relapsed APL patients than in both complete remission and non-leukemia cases, closely correlating with the leukemogenesis of APL. Taken together, our studies revealed for the first time the importance of miR-181a-mediated AC9 downregulation in APL. We also suggested the potential value of AC9 as a biomarker in the clinical diagnosis and treatment of leukemia.

  14. DEVELOPMENT OF ACCELERATOR DATA REPORTING SYSTEM AND ITS APPLICATION TO TREND ANALYSIS OF BEAM CURRENT DATA

    SciTech Connect

    Padilla, M.J.; Blokland, W.

    2009-01-01

    Detailed ongoing information about the ion beam quality is crucial to the successful operation of the Spallation Neutron Source at Oak Ridge National Laboratory. In order to provide the highest possible neutron production time, ion beam quality is monitored to isolate possible problems or performance-related issues throughout the accelerator and accumulator ring. For example, beam current monitor (BCM) data is used to determine the quality of the beam transport through the accelerator. In this study, a reporting system infrastructure was implemented and used to generate a trend analysis report of the BCM data. The BCM data was analyzed to facilitate the identifi cation of monitor calibration issues, beam trends, beam abnormalities, beam deviations and overall beam quality. A comparison between transformed BCM report data and accelerator log entries shows promising results which represent correlations between the data and changes made within the accelerator. The BCM analysis report is one of many reports within a system that assist in providing overall beam quality information to facilitate successful beam operation. In future reports, additional data manipulation functions and analysis can be implemented and applied. Built-in and user-defi ned analytic functions are available throughout the reporting system and can be reused with new data.

  15. Limiting electron beam current for cyclic induction acceleration in a constant guide field

    SciTech Connect

    Kanunnikov, V.N.

    1982-09-01

    Theoretical relations are derived for the limiting beam current in a cyclic induction accelerator (CIA) with a constant guide field. The calculations are in agreement with the available experimental data. It is shown that the limiting average beam current in a CIA is of the order of 100 microamperes, i.e., the level attained in microtrons and linear accelerators. The CIA may find industrial applications.

  16. Instrument for spatially resolved simultaneous measurements of forces and currents in particle beams

    SciTech Connect

    Spethmann, A. Trottenberg, T. Kersten, H.

    2015-01-15

    The article presents a device for spatially resolved and simultaneous measurements of forces and currents in particle beams, especially in beams composed of ions and neutral atoms. The forces are exerted by the impinging beam particles on a plane circular conductive target plate of 20 mm diameter mounted on a pendulum with electromagnetic force compensation. The force measurement in the micronewton range is achieved by electromagnetic compensation by means of static Helmholtz coils and permanent magnets attached to the pendulum. Exemplary measurements are performed in the 1.2 keV beam of a broad beam ion source. The simultaneous measurements of forces and currents onto the same target are compared with each other and with Faraday cup measurements.

  17. Synchrotron X-ray micro-beam studies of ancient Egyptian make-up

    NASA Astrophysics Data System (ADS)

    Martinetto, P.; Anne, M.; Dooryhée, E.; Drakopoulos, M.; Dubus, M.; Salomon, J.; Simionovici, A.; Walter, Ph.

    2001-07-01

    Vases full of make-up are most often present in the burial furniture of Egyptian tombs dated from the pharaonic period. The powdered cosmetics made of isolated grains are analysed to identify their trace element signature. From this signature we identify the provenance of the mineral ingredients in the make-up and we observe different impurities in products, which have been demonstrated as synthetic substances by previous works. Focused X-ray micro-beam ( 2×5 μm2) is successively tuned at 11 keV, below the L III absorption edge of Pb, and 31.8 keV for global characterisation of the metal impurities. The fluorescence signal integrated over each single grain is detected against the X-ray micro-diffraction pattern collected in transmission with a bi-dimensional detector. Furthermore, for galena grains rich in Zn, the XANES signal at the K-absorption edge of Zn shows its immediate nearest-neighbour environment.

  18. LabVIEW control software for scanning micro-beam X-ray fluorescence spectrometer.

    PubMed

    Wrobel, Pawel; Czyzycki, Mateusz; Furman, Leszek; Kolasinski, Krzysztof; Lankosz, Marek; Mrenca, Alina; Samek, Lucyna; Wegrzynek, Dariusz

    2012-05-15

    Confocal micro-beam X-ray fluorescence microscope was constructed. The system was assembled from commercially available components - a low power X-ray tube source, polycapillary X-ray optics and silicon drift detector - controlled by an in-house developed LabVIEW software. A video camera coupled to optical microscope was utilized to display the area excited by X-ray beam. The camera image calibration and scan area definition software were also based entirely on LabVIEW code. Presently, the main area of application of the newly constructed spectrometer is 2-dimensional mapping of element distribution in environmental, biological and geological samples with micrometer spatial resolution. The hardware and the developed software can already handle volumetric 3-D confocal scans. In this work, a front panel graphical user interface as well as communication protocols between hardware components were described. Two applications of the spectrometer, to homogeneity testing of titanium layers and to imaging of various types of grains in air particulate matter collected on membrane filters, were presented.

  19. Development of a Beam Hardening Correction Method for a microCT Scanner Prototype

    SciTech Connect

    Kikushima, J.; Rodriguez-Villafuerte, M.; Martinez-Davalos, A.

    2010-12-07

    The radiographic projections acquired with a microCT were simulated and then corrected for beam hardening effects using the linearized signal to equivalent thickness (LSET) method. This procedure requires a calibration signal for each pixel obtained from a set of images with filters of increasing thickness. The projections are corrected by converting the signal to an equivalent thickness using interpolation over the calibration images. The method was validated using simulated projections of different phantoms. Two calibration sets were simulated using aluminum and water filters of thicknesses ranging from 0 to 5 mm and from 0 to 50 mm, respectively. A simulation of the phantoms' projections using a monoenergetic beam was also obtained to establish the relative intensity on the tomographic images when no cupping artifacts are present. Comparison between corrected and uncorrected tomographic images shows that the LSET method effectively corrects the cupping artifact. Streaking artifacts correction with the LSET method shows better results than with the traditional water correction method. Results are independent of the two calibration materials used.

  20. A micro-force sensor with slotted-quad-beam structure for measuring the friction in MEMS bearings.

    PubMed

    Liu, Huan; Yang, Shuming; Zhao, Yulong; Jiang, Zhuangde; Liu, Yan; Tian, Bian

    2013-09-30

    Presented here is a slotted-quad-beam structure sensor for the measurement of friction in micro bearings. Stress concentration slots are incorporated into a conventional quad-beam structure to improve the sensitivity of force measurements. The performance comparison between the quad-beam structure sensor and the slotted-quad-beam structure sensor are performed by theoretical modeling and finite element (FE) analysis. A hollow stainless steel probe is attached to the mesa of the sensor chip by a tailor-made organic glass fixture. Concerning the overload protection of the fragile beams, a glass wafer is bonded onto the bottom of sensor chip to limit the displacement of the mesa. The calibration of the packaged device is experimentally performed by a tri-dimensional positioning stage, a precision piezoelectric ceramic and an electronic analytical balance, which indicates its favorable sensitivity and overload protection. To verify the potential of the proposed sensor being applied in micro friction measurement, a measurement platform is established. The output of the sensor reflects the friction of bearing resulting from dry friction and solid lubrication. The results accord with the theoretical modeling and demonstrate that the sensor has the potential application in measuring the micro friction force under stable stage in MEMS machines.

  1. A frequency independent approximation and a sliding mode control scheme for a system of a micro-cantilever beam.

    PubMed

    Vagia, Marialena

    2012-03-01

    In the present article, a sliding mode controller is proposed for a micro-cantilever beam (μCB) with fringing and squeezed film damping effects. The narrow micro-cantilever beam can move via the application of an external electrically induced force. The introduction of the squeezed film parameters results in a frequency-dependent nonlinear system. Particular attention, has been paid, in order to approximate the frequency dependent μCB model, with a valid, frequency independent one, that would be incorporated in the design of a robust sliding mode controller. The suggested control technique enables compact realization of a robust controller tolerant in device characteristics' variations, nonlinearities and types of inherent instabilities. Robustness of the proposed control scheme against disturbances is proved by Lyapunov's second method. In addition, bifurcation analysis is carried on the beam's nonlinear model, and numerous simulation test cases are presented in order to test the suggested modeling and control techniques.

  2. Nano-structuring of polymer surfaces by multi-beam laser interference for application in micro-fluidics

    NASA Astrophysics Data System (ADS)

    Klotzbuecher, T.; Radke, A.; Tunayar, A.; Haverbeck, O.; Weinbender, E.; Wuesten, J.; Toufali, A.; Claussen, J.; Detemple, P.

    2008-02-01

    The interference of three coherent laser beams of a HeCd-laser with a wavelength of 325 nm was used to create a periodic intensity distribution into the photo-resist AZ4562. The beam configuration for the laser beam interference was carefully chosen, so that well defined patterns of two-dimensional periodicity were generated in the photo-resist. Moulding tools were fabricated from the generated nano-structures via electroforming processes, allowing for a fast replication of the nano-structured surfaces via hot embossing. Hot embossed polymers were used to increase the effective surface of micro-fluidic devices like e.g. Polymerase-Chain-Reaction(PCR)-chips. The Nano-structured surfaces were characterized concerning their contact angles when wetted with de-ionized water. It was found that the nano-structures influenced the wetting behaviour of micro-fluidic chip surfaces clearly, especially Polypropylene (PP) surfaces showed a superhydrophobic behaviour.

  3. Resolution Improvement and Pattern Generator Development for theMaskless Micro-Ion-Beam Reduction Lithography System

    SciTech Connect

    Jiang, Ximan

    2006-05-18

    have been studied. The dependence of the throughput with the exposure field size and the speed of the mechanical stage has been investigated. In order to perform maskless lithography, different micro-fabricated pattern generators have been developed for the MMRL system. Ion beamlet switching has been successfully demonstrated on the MMRL system. A positive bias voltage around 10 volts is sufficient to switch off the ion current on the micro-fabricated pattern generators. Some unexpected problems, such as the high-energy secondary electron radiations, have been discovered during the experimental investigation. Thermal and structural analysis indicates that the aperture displacement error induced by thermal expansion can satisfy the 3δ CD requirement for lithography nodes down to 25 nm. The cross-talking effect near the surface and inside the apertures of the pattern generator has been simulated in a 3-D ray-tracing code. New pattern generator design has been proposed to reduce the cross-talking effect. In order to eliminate the surface charging effect caused by the secondary electrons, a new beam-switching scheme in which the switching electrodes are immersed in the plasma has been demonstrated on a mechanically fabricated pattern generator.

  4. Influence of total beam current on HRTEM image resolution in differentially pumped ETEM with nitrogen gas.

    PubMed

    Bright, A N; Yoshida, K; Tanaka, N

    2013-01-01

    Environmental transmission electron microscopy (ETEM) enables the study of catalytic and other reaction processes as they occur with Angstrom-level resolution. The microscope used is a dedicated ETEM (Titan ETEM, FEI Company) with a differential pumping vacuum system and apertures, allowing aberration corrected high-resolution transmission electron microscopy (HRTEM) imaging to be performed with gas pressures up to 20 mbar in the sample area and with significant advantages over membrane-type E-cell holders. The effect on image resolution of varying the nitrogen gas pressure, electron beam current density and total beam current were measured using information limit (Young's fringes) on a standard cross grating sample and from silicon crystal lattice imaging. As expected, increasing gas pressure causes a decrease in HRTEM image resolution. However, the total electron beam current also causes big changes in the image resolution (lower beam current giving better resolution), whereas varying the beam current density has almost no effect on resolution, a result that has not been reported previously. This behavior is seen even with zero-loss filtered imaging, which we believe shows that the drop in resolution is caused by elastic scattering at gas ions created by the incident electron beam. Suitable conditions for acquiring high resolution images in a gas environment are discussed. Lattice images at nitrogen pressures up to 16 mbar are shown, with 0.12 nm information transfer at 4 mbar.

  5. High beam current shut-off systems in the APS linac and low energy transfer line

    SciTech Connect

    Wang, X.; Knott, M.; Lumpkin, A.

    1994-11-01

    Two independent high beam current shut-off current monitoring systems (BESOCM) have been installed in the APS linac and the low energy transport line to provide personnel safety protection in the event of acceleration of excessive beam currents. Beam current is monitored by a fast current transformer (FCT) and fully redundant supervisory circuits connected to the Access Control Interlock System (ACIS) for beam intensity related shutdowns of the linac. One FCT is located at the end of the positron linac and the other in the low energy transport line, which directs beam to the positron accumulator ring (PAR). To ensure a high degree of reliability, both systems employ a continuous self-checking function, which injects a test pulse to a single-turn test winding after each ``real`` beam pulse to verify that the system is fully functional. The system is designed to be fail-safe for all possible system faults, such as loss of power, open or shorted signal or test cables, loss of external trigger, malfunction of gated integrator, etc. The system has been successfully commissioned and is now a reliable part of the total ACIS.

  6. High beam current shut-off systems in the APS linac and low energy transfer line

    SciTech Connect

    Wang, X.; Knott, M.; Lumpkin, A.

    1995-05-05

    Two independent high beam current shut-off current monitoring systems (BESOCM) have been installed in the APS linac and the low energy transport line to provide personnel safety protection in the event of acceleration of excessive beam currents. Beam current is monitored by a fast current transformer (FCT) and fully redundant supervisory circuits connected to the Access Control Interlock System (ACIS) for beam intensity related shutdowns of the linac. One FCT is located at the end of the positron linac and the other in the low energy transport line, which directs beam to the positron accumulator ring (PAR). To ensure a high degree of reliability, both systems employ a continuous self-checking function, which injects a test pulse to a single-turn test winding after each ``real`` beam pulse to verify that the system is fully functional. The system is designed to be fail-safe for all possible system faults, such as loss of power, open or shorted signal or test cables, loss of external trigger, malfunction of gated integrator, etc. The system has been successfully commissioned and is now a reliable part of the total ACIS. {copyright} {ital 1995} {ital American} {ital Institute} {ital of} {ital Physics}.

  7. Current Limiting Mechanisms in Electron and Ion Beams Experiments

    DTIC Science & Technology

    1989-08-07

    comparable to the emitted current. The thermal electron flux in the ionosphere is J = e n VkT -iii- - 2 x 10- 4 A/m 2. For a collecting area of 10 m 2...arcjet fires; upper curves follow in time as the shuttle orbiter charges. Figure 3. SPACELAB-1/SEPAC electron distribution functions calculated from the

  8. Effect of conductive screens on the stabilization of plasma channels with currents of hundreds kAmps

    NASA Astrophysics Data System (ADS)

    Bochkov, V. D.; Bochkov, D. V.; Krivosheev, S. I.; Adamian, Yu. E.

    2016-12-01

    Based on experimental data, we analyzed the results of the influence of external conductive shield on stabilization of plasma channels in high-power pseudospark switches—thyratrons TDI-type. Both no-ferrous and ferrous shields are tested. The research is a part of a work on improvement of switching capabilities of thyratrons capable of transferring currents up to hundreds kA with switching energy more than 50 kJ.

  9. Determination of the beam quality correction factor k_{Q,Q_0 } for the microLion chamber in a clinical photon beam

    NASA Astrophysics Data System (ADS)

    Choi, Sang Hyoun; Kim, Chan Hyeong; Huh, Hyun Do; Kim, Kum-Bae; Kim, SeongHoon

    2013-01-01

    The mcroLion chamber, which has a small volume (0.0017cc) and a high sensitivity suitable for small field dosimetry, is an ionization chamber with liquid (isooctane) filling the cavity volume. In the present work, we used two alternative ways to estimate the beam quality correction factor k_{Q,Q_0 }^{micL} of the microLion chamber in the 6 MV photon beam from a Clinac iX accelerator (Varian, USA); Monte Carlo simulations and experimental methods. The Monte Carlo calculation (1.0183 ± 0.58%) agreed to within 0.56% with the experimental determination (1.024 ± 0.58%). The results from the two methods were in good agreement within acceptable uncertainties. We think that the averaged factor, 1.0212, could be used for the microLion chamber in reference dosimetry.

  10. Return current effects in passive plasma lenses for relativistic electron beams

    NASA Astrophysics Data System (ADS)

    Govil, Richa

    This thesis presents results of an experimental study of return currents effects on beam focusing in plasma lenses conducted at the Beam Test Facility (BTF) at Lawrence Berkeley National Laboratory (LBNL). Relativistic electron beams can be focused in field-free plasmas due to magnetic self-pinching. However, plasma return currents induced by the changing magnetic flux of a propagating bunch can reduce the total magnetic field and focusing force (Ampere's law). The experiment covered a parameter regime not observed previously, namely, the return current regime, where the collisionless plasma skindepth is small compared to the electron beam size and the focusing strength of the plasma lens is reduced due to return currents. A relativistic electron beam from the BTF, which utilizes the Advanced Light Source (ALS) injector, was used to study the properties of return currents in plasmas. The beam-transport line and experimental chamber were designed to allow measurement of electron beam size continuously along its path, before and after it passed through plasma lenses. For this purpose, an optical transition radiation (OTR) based diagnostic was developed. To ensure plasmas free of external fields, laser- ionization was chosen as the plasma production method. The dependence of plasma density on fill pressure and laser intensity was studied with an in-quadrature Mach- Zehnder radio frequency interferometer. A novel interferometry technique based on evanescent wave detection was developed to measure plasma densities above the cutoff density, for plasmas with a thickness less than the collisionless skin depth. Plasma density was controlled by changing the fill-pressure in the chamber, while the plasma profile was adjusted through the laser intensity. For typical experimental parameters, the electron beam size was observed to reduce in the presence of plasma. Plasma lenses were produced in the return current regime with the ratio of beam size to collisionless plasma

  11. RESULTS OF BEAM TESTS ON A HIGH CURRENT EBIS TEST STAND.

    SciTech Connect

    BEEBE,E.; ALESSI,J.; BELLAVIA,S.; HERSHCOVITCH,A.; KPONOU,A.; LOCKEY,R.; PIKIN,A.; PRELEC,K.; KUZNETSOV,G.; TIUNOV,M.

    1999-03-29

    At Brookhaven National Laboratory there is an R&D program to design an Electron Beam Ion Source (EBIS) for use in a compact ion injector to be developed for the relativistic heavy ion collider (RHIC). The BNL effort is directed at developing an EBIS with intensities of 3 x 10{sup 9} particles/pulse of ions such as Au{sup 35+} and U{sup 45+}, and requires an electron beam on the order of 10A. The construction of a test stand (EBTS) with the full electron beam power and 1/3 the length of the EBIS for RHIC is nearing completion. Initial commissioning of the EBTS was made with pulsed electron beams of duration < 1ms and current up to 13 A. Details of the EBTS construction, results of the pulse tests, and preparations for DC electron beam tests are presented.

  12. Mapping of ion beam induced current changes in FinFETs

    SciTech Connect

    Weis, C. D.; Schuh, A.; Batra, A.; Persaud, A.; Rangelow, I. W.; Bokor, J.; Lo, C. C.; Cabrini, S.; Olynick, D.; Duhey, S.; Schenkel, T.

    2008-09-30

    We report on progress in ion placement into silicon devices with scanning probealignment. The device is imaged with a scanning force microscope (SFM) and an aligned argon beam (20 keV, 36 keV) is scanned over the transistor surface. Holes in the lever of the SFM tip collimate the argon beam to sizes of 1.6 mu m and 100 nm in diameter. Ion impacts upset the channel current due to formation of positive charges in the oxide areas. The induced changes in the source-drain current are recorded in dependence of the ion beam position in respect to the FinFET. Maps of local areas responding to the ion beam are obtained.

  13. The effect of beam-driven return current instability on solar hard X-ray bursts

    NASA Technical Reports Server (NTRS)

    Cromwell, D.; Mcquillan, P.; Brown, J. C.

    1986-01-01

    The problem of electrostatic wave generation by a return current driven by a small area electron beam during solar hard X-ray bursts is discussed. The marginal stability method is used to solve numerically the electron and ion heating equations for a prescribed beam current evolution. When ion-acoustic waves are considered, the method appears satisfactory and, following an initial phase of Coulomb resistivity in which T sub e/T sub i rise, predicts a rapid heating of substantial plasma volumes by anomalous ohmic dissipation. This hot plasma emits so much thermal bremsstrahlung that, contrary to previous expectations, the unstable beam-plasma system actually emits more hard X-rays than does the beam in the purely collisional thick target regime relevant to larger injection areas. Inclusion of ion-cyclotron waves results in ion-acoustic wave onset at lower T sub e/T sub i and a marginal stability treatment yields unphysical results.

  14. Current Control in ITER Steady State Plasmas With Neutral Beam Steering

    SciTech Connect

    R.V. Budny

    2009-09-10

    Predictions of quasi steady state DT plasmas in ITER are generated using the PTRANSP code. The plasma temperatures, densities, boundary shape, and total current (9 - 10 MA) anticipated for ITER steady state plasmas are specified. Current drive by negative ion neutral beam injection, lower-hybrid, and electron cyclotron resonance are calculated. Four modes of operation with different combinations of current drive are studied. For each mode, scans with the NNBI aimed at differing heights in the plasma are performed to study effects of current control on the q profile. The timeevolution of the currents and q are calculated to evaluate long duration transients. Quasi steady state, strongly reversed q profiles are predicted for some beam injection angles if the current drive and bootstrap currents are sufficiently large.

  15. Numerical study of the two-species Vlasov-Ampère system: Energy-conserving schemes and the current-driven ion-acoustic instability

    NASA Astrophysics Data System (ADS)

    Cheng, Yingda; Christlieb, Andrew J.; Zhong, Xinghui

    2015-05-01

    In this paper, we propose energy-conserving Eulerian solvers for the two-species Vlasov-Ampère (VA) system and apply the methods to simulate current-driven ion-acoustic instability. The two-species VA systems are of practical importance in applications, and they conserve many physical quantities including the particle number of each species and the total energy that is comprised of kinetic energy for both species and the electric energy. The main goal of this paper is to generalize our previous work for the single-species VA system [9] and Vlasov-Maxwell (VM) system [8] to the two-species case. The methodologies proposed involve careful design of temporal discretization and the use of the discontinuous Galerkin (DG) spatial discretizations. We show that the energy-conserving time discretizations for single-species equations [9,8] can also work for the two-species case if extended properly. Compared to other high order schemes, we emphasize that our schemes can preserve the total particle number and total energy on the fully discrete level regardless of mesh size, making them very attractive for long time simulations. We benchmark our algorithms on a test example to check the one-species limit, and the current-driven ion-acoustic instability. To simulate the current-driven ion-acoustic instability, a slight modification for the implicit method is necessary to fully decouple the split equations. This is achieved by a Gauss-Seidel type iteration technique. Numerical results verified the conservation and performance of our methods. Finally, we remark that the schemes in this paper can be readily extended to applications when the models take more general form, such as the multi-species VM equations.

  16. Design of the beam shut-off current monitor upgrade for the Advanced Photon Source

    SciTech Connect

    Pietryla, A.; Decker, G.

    2000-05-05

    Plans to eliminate the positron accumulator ring (PAR) from the Advanced Photon Source (APS) injector complex have created the need for a device to limit the allowable beam charge injected into the APS injector synchrotrons. The beam shut-off current monitor (BESOCM) was chosen to provide this function. This new application of the BESOCM provided the opportunity to explore new design philosophies. Two design goals were to de-emphasize reliance on external signals and to become insensitive to timing variations. Both of these goals were accomplished by deriving the trigger directly from the beam. This paper will discuss the features of the new BESOCM design and present data demonstrating its function.

  17. Micro-contacting of single and periodically arrayed columnar silicon structures by focused ion beam techniques

    SciTech Connect

    Friedrich, F. Herfurth, N.; Teodoreanu, A.-M.; Boit, C.

    2014-06-16

    Micron-sized, periodic crystalline Silicon columns on glass substrate were electrically contacted with a transparent conductive oxide front contact and a focused ion beam processed local back contact. Individual column contacts as well as arrays of >100 contacted columns were processed. Current-voltage characteristics of the devices were determined. By comparison with characteristics obtained from adapted device simulation, the absorber defect density was reconstructed. The contacting scheme allows the fabrication of testing devices in order to evaluate the electronic potential of promising semiconductor microstructures.

  18. ERDA with an external helium ion micro-beam: Advantages and potential applications

    NASA Astrophysics Data System (ADS)

    Calligaro, T.; Castaing, J.; Dran, J.-C.; Moignard, B.; Pivin, J.-C.; Prasad, G. V. R.; Salomon, J.; Walter, P.

    2001-07-01

    Preliminary ERDA experiments at atmospheric pressure have been performed with our external microprobe set-up currently used for the analysis of museum objects by PIXE, RBS and NRA. The objective was to check the feasibility of hydrogen (and deuterium) profiling with an external beam of 3-MeV helium ions. The standard scattering geometry (incident beam at 15° with respect to sample surface and emerging protons or deuterons at 15° in the forward direction) was kept, but the thin foil absorber was replaced by helium gas filling the space between the beam spot and the detector over a distance of about 84 mm. Several standards prepared by ion implantation, with well known H or D depth profiles, were first analysed, which indicated that the analytical capability was as good as under vacuum. A striking feature is the much lower surface peak than under vacuum, a fact that enhances the sensitivity for H analysis near the surface. The same type of measurement was then performed on different materials to show the usefulness of the technique. As a first example, we have checked that the incorporation of H or D into sapphire crystals during mechanical polishing is below the detection limit. Another example is the measurement of the H content in emeralds which can be used as an additional compositional criterion for determining the provenance of emeralds set in museum jewels. The advantages and limitations of our set-up are discussed and several possible applications in the field of cultural heritage are described.

  19. Generation of high-current electron beam in a wide-aperture open discharge

    NASA Astrophysics Data System (ADS)

    Bokhan, P. A.; Zakrevsky, Dm. E.; Gugin, P. P.

    2011-10-01

    In the present study, it was examined generation of nanosecond-duration electron-beam (EB) pulses by a wide-aperture open discharge burning in helium or in a mixture of helium with nitrogen and water vapor. In the experiments, a discharge cell with coaxial electrode geometry, permitting radial injection of the electron beam into operating lasing medium, was used, with the cathode having radius 2.5 cm and length 12 cm. It was shown possible to achieve an efficient generation of a high-intensity electron beam (EB pulse power ˜250 MW and EB pulse energy up to 4 J) in the kiloampere range of discharge currents (up to 26 kA at ˜12 kV discharge voltage). The current-voltage characteristics of the discharge proved to be independent of the working-gas pressure. The existence of an unstable dynamic state of EB, conditioned by the presence of an uncompensated space charge accumulated in the discharge cell due to the exponential growth of the current in time during discharge initiation and the hyperbolic growth of current density in the direction towards the tube axis, was revealed. The obtained pulsed electron beam was used to excite the self-terminated laser on He 21P10-21S0 transition. The oscillations developing in the discharge cell at high discharge currents put limit to the pumping energy and emissive power of the laser excited with the radially converging electron beam.

  20. Spontaneous decoration of Au nanoparticles on micro-patterned reduced graphene oxide shaped by focused laser beam

    SciTech Connect

    Wan, Y. C.; Tok, E. S.; Teoh, H. F.; Sow, C. H.

    2015-02-07

    We report a facile, two-step method for the micro-landscaping of Au nanoparticles(NPs) on reduced graphene oxide (rGO) film en route to micro-patterned Au(NPs)-rGO hybrid functional materials. This method employs a focused laser beam to first locally convert GO to rGO before immersing the micro-patterned GO-rGO film into HAuCl{sub 4} solution. The rGO micro-pattern, shaped by the focused laser beam, serves as nucleation sites for the reduction of Au ions. The reduction mechanism that governs the decoration of Au NPs on rGO films is akin to electroless deposition process. In this instance, surface charges that are formed during laser reduction of GO to rGO provide active nucleation sites for Au{sup 3+} ions to form Au NPs when HAuCl{sub 4} solution is introduced. The number density, the size, and size distribution of the Au NPs can thus be directly tuned and preferentially anchored onto the rGO micro-pattern by varying the incident laser power, the scanning speed of the laser, or the concentration of HAuCl{sub 4}. The resulting hybrid materials can be used as a substrate for Surface Enhanced Raman Spectroscopy (SERS). Using Rhodamine 6G as the test subject, we found an improvement of SERS enhancement over bare rGO of up to four times, depending on the size of the Au NPs.

  1. Amps particle accelerator definition study

    NASA Technical Reports Server (NTRS)

    Sellen, J. M., Jr.

    1975-01-01

    The Particle Accelerator System of the AMPS (Atmospheric, Magnetospheric, and Plasmas in Space) payload is a series of charged particle accelerators to be flown with the Space Transportation System Shuttle on Spacelab missions. In the configuration presented, the total particle accelerator system consists of an energetic electron beam, an energetic ion accelerator, and both low voltage and high voltage plasma acceleration devices. The Orbiter is illustrated with such a particle accelerator system.

  2. Femtosecond laser fabrication of micro and nano-disks in single layer graphene using vortex Bessel beams

    SciTech Connect

    Wetzel, Benjamin Xie, Chen; Lacourt, Pierre-Ambroise; Dudley, John M.; Courvoisier, Francois

    2013-12-09

    We report the fabrication of micro and nano-disks in single layer chemical vapor deposition graphene on glass substrate using femtosecond laser ablation with vortex Bessel beams. The fabricated graphene disks with diameters ranging from 650 nm to 4 μm were characterized by spatially resolved micro-Raman spectroscopy. The variation of ablation threshold was investigated as a function of the number of pulses showing an incubation effect. A very high degree of size control of the fabricated graphene disks is enabled using a sequence of femtosecond pulses with different vortex orders.

  3. Enhanced current and power density of micro-scale microbial fuel cells with ultramicroelectrode anodes

    NASA Astrophysics Data System (ADS)

    Ren, Hao; Rangaswami, Sriram; Lee, Hyung-Sool; Chae, Junseok

    2016-09-01

    We present a micro-scale microbial fuel cell (MFC) with an ultramicroelectrode (UME) anode, with the aim of creating a miniaturized high-current/power-density converter using carbon-neutral and renewable energy sources. Micro-scale MFCs have been studied for more than a decade, yet their current and power densities are still an order of magnitude lower than those of their macro-scale counterparts. In order to enhance the current/power densities, we engineer a concentric ring-shaped UME, with a width of 20 μm, to facilitate the diffusion of ions in the vicinity of the micro-organisms that form biofilm on the UME. The biofilm extends approximately 15 μm from the edge of the UME, suggesting the effective biofilm area increases. Measured current/power densities per the effective area and the original anode area are 7.08  ±  0.01 A m-2 & 3.09  ±  0.04 W m-2 and 17.7  ±  0.03 A m-2 & 7.72  ±  0.09 W m-2, respectively. This is substantially higher than any prior work in micro-scale MFCs, and very close, or even higher, to that of macro-scale MFCs. A Coulombic efficiency, a measure of how efficiently an MFC harvests electrons from donor substrate, of 70%, and an energy conversion efficiency of 17% are marked, highlighting the micro-scale MFC as an attractive alternative within the existing energy conversion portfolio.

  4. Effects of micro- and nanoplastics on aquatic ecosystems: Current research trends and perspectives.

    PubMed

    Chae, Yooeun; An, Youn-Joo

    2017-02-17

    Contamination by bulk plastics and plastic debris is currently the one of the most serious environmental problems in aquatic ecosystems. In particular, small-scale plastic debris such as microplastics and nanoplastics has become leading contributors to the pollution of marine and freshwater ecosystems. Studies are investigating the impacts of micro-and nanoplastics on aquatic organisms and ecosystems worldwide. This review covers 83 studies that investigated the distribution of microplastics and the ecotoxicity of micro- and nanoplastics in marine and freshwater ecosystems. The studies indicated that micro-sized plastics and plastic debris were distributed at various concentrations in aquatic ecosystems around the world. They had various effects on the growth, development, behavior, reproduction, and mortality of aquatic animals. We discuss these studies in detail and suggest directions for future research.

  5. Effects of a dielectric material in an ion source on the ion beam current density and ion beam energy

    SciTech Connect

    Fujiwara, Y. Sakakita, H.; Nakamiya, A.; Hirano, Y.; Kiyama, S.

    2016-02-15

    To understand a strong focusing phenomenon that occurs in a low-energy hydrogen ion beam, the electron temperature, the electron density, and the space potential in an ion source with cusped magnetic fields are measured before and after the transition to the focusing state using an electrostatic probe. The experimental results show that no significant changes are observed before or after the transition. However, we found unique phenomena that are characterized by the position of the electrostatic probe in the ion source chamber. Specifically, the extracted ion beam current density and energy are obviously enhanced in the case where the electrostatic probe, which is covered by a dielectric material, is placed close to an acceleration electrode.

  6. 3D Medipix2 detector characterization with a micro-focused X-ray beam

    NASA Astrophysics Data System (ADS)

    Gimenez, E. N.; Maneuski, D.; Mac Raighne, A.; Parkes, C.; Bates, R.; O'Shea, V.; Fleta, C.; Pellegrini, G.; Lozano, M.; Alianelli, L.; Sawhney, K. J. S.; Marchal, J.; Tartoni, N.

    2011-05-01

    Three-dimensional (3D) photodiode detectors offer advantages over standard planar photodiodes in a wide range of applications. The main advantage of these sensors for X-ray imaging is their reduced charge sharing between adjacent pixels, which could improve spatial and spectral resolution. However, a drawback of 3D sensors structures is the loss of detection efficiency due to the presence in the pixel structure of heavily doped electrode columns which are insensitive to X-ray. In this work two types of 3D silicon detectors: n-type wafer with hole collecting readout-columns (N-TYPE) and p-type wafer with electron collecting readout-columns (P-TYPE), bump-bounded to a Medipix2 read-out chip were characterized with a 14.5 keV micro-focused X-ray beam from a synchrotron. Measurements of the detection efficiency and the charge sharing were performed at different bias voltages and Medipix2 energy thresholds and compared with those of a standard planar silicon sensor.

  7. Iterative reconstruction optimisations for high angle cone-beam micro-CT

    NASA Astrophysics Data System (ADS)

    Recur, B.; Fauconneau, M.; Kingston, A.; Myers, G.; Sheppard, A.

    2014-09-01

    We address several acquisition questions that have arisen for the high cone-angle helical-scanning micro-CT facility developed at the Australian National University. These challenges are generally known in medical and industrial cone-beam scanners but can be neglected in these systems. For our large datasets, with more than 20483 voxels, minimising the number of operations (or iterations) is crucial. Large cone-angles enable high signal-to-noise ratio imaging and a large helical pitch to be used. This introduces two challenges: (i) non-uniform resolution throughout the reconstruction, (ii) over-scan beyond the region-of-interest significantly increases re- quired reconstructed volume size. Challenge (i) can be addressed by using a double-helix or lower pitch helix but both solutions slow down iterations. Challenge (ii) can also be improved by using a lower pitch helix but results in more projections slowing down iterations. This may be overcome using less projections per revolution but leads to more iterations required. Here we assume a given total time for acquisition and a given reconstruction technique (SART) and seek to identify the optimal trajectory and number of projections per revolution in order to produce the best tomogram, minimise reconstruction time required, and minimise memory requirements.

  8. Trapped electron correction to beam driven current in general tokamak equilibria

    SciTech Connect

    Lin-Liu, Y.R.; Hinton, F.L.

    1997-11-01

    In the limit that the electron thermal velocity greatly exceeds the fast ion velocity for electrical currents driven by neutral beams, the trapped electron correction to the Ohkawa current and the electron density gradient contribution to bootstrap current are shown to share the same transport coefficient in the banana regime. Therefore, existing analytic expressions for the bootstrap coefficient valid for arbitrary aspect ratio tokamaks can also be used to calculate the trapped electron effect. {copyright} {ital 1997 American Institute of Physics.}

  9. Start-to-end beam dynamics simulation of double triangular current profile generation in Argonne Wakefield Accelerator

    SciTech Connect

    Ha, G.; Power, J.; Kim, S. H.; Gai, W.; Kim, K.-J.; Cho, M. H.; Namkung, W.

    2012-12-21

    Double triangular current profile (DT) gives a high transformer ratio which is the determining factor of the performance of collinear wakefield accelerator. This current profile can be generated using the emittance exchange (EEX) beam line. Argonne Wakefield Accelerator (AWA) facility plans to generate DT using the EEX beam line. We conducted start-to-end simulation for the AWA beam line using PARMELA code. Also, we discuss requirements of beam parameters for the generation of DT.

  10. A new method to calculate the beam charge for an integrating current transformer

    SciTech Connect

    Wu Yuchi; Han Dan; Zhu Bin; Dong Kegong; Tan Fang; Gu Yuqiu

    2012-09-15

    The integrating current transformer (ICT) is a magnetic sensor widely used to precisely measure the charge of an ultra-short-pulse charged particle beam generated by traditional accelerators and new laser-plasma particle accelerators. In this paper, we present a new method to calculate the beam charge in an ICT based on circuit analysis. The output transfer function shows an invariable signal profile for an ultra-short electron bunch, so the function can be used to evaluate the signal quality and calculate the beam charge through signal fitting. We obtain a set of parameters in the output function from a standard signal generated by an ultra-short electron bunch (about 1 ps in duration) at a radio frequency linear electron accelerator at Tsinghua University. These parameters can be used to obtain the beam charge by signal fitting with excellent accuracy.

  11. Modulation of auroral electrojet currents using dual HF beams with ELF phase offset

    NASA Astrophysics Data System (ADS)

    Golkowski, M.; Cohen, M.; Moore, R. C.

    2012-12-01

    The modulation of naturally occuring ionospheric currents with high power radio waves in the high frequency (HF, 3-10 MHz) band is a well known technique for generation of extremely low frequency (ELF, 3-3000 Hz) and very low frequency (VLF, 3-30 kHz) waves. We use the heating facility of the High Frequency Active Auroral Research Program (HAARP) to investigate the effect of using dual HF beams with an ELF/VLF phase offset between the modulation waveforms. Experiments with offset HF beams confirm the model of independent ELF/VLF sources. Experiments with co-located HF beams exhibit interaction between the first and second harmonics of the modulated tones when square and sine wave modulation waveforms are employed. Using ELF/VLF phase offsets for co-loacted beams is also shown to be a potential diagnostic for the D-region ionospheric profile.

  12. Cyclic AMP in prokaryotes.

    PubMed Central

    Botsford, J L; Harman, J G

    1992-01-01

    Cyclic AMP (cAMP) is found in a variety of prokaryotes including both eubacteria and archaebacteria. cAMP plays a role in regulating gene expression, not only for the classic inducible catabolic operons, but also for other categories. In the enteric coliforms, the effects of cAMP on gene expression are mediated through its interaction with and allosteric modification of a cAMP-binding protein (CRP). The CRP-cAMP complex subsequently binds specific DNA sequences and either activates or inhibits transcription depending upon the positioning of the complex relative to the promoter. Enteric coliforms have provided a model to explore the mechanisms involved in controlling adenylate cyclase activity, in regulating adenylate cyclase synthesis, and in performing detailed examinations of CRP-cAMP complex-regulated gene expression. This review summarizes recent work focused on elucidating the molecular mechanisms of CRP-cAMP complex-mediated processes. For other bacteria, less detail is known. cAMP has been implicated in regulating antibiotic production, phototrophic growth, and pathogenesis. A role for cAMP has been suggested in nitrogen fixation. Often the only data that support cAMP involvement in these processes includes cAMP measurement, detection of the enzymes involved in cAMP metabolism, or observed effects of high concentrations of the nucleotide on cell growth. PMID:1315922

  13. Evolution of relativistic electron current beam in a cold plasma with fixed background of ions

    NASA Astrophysics Data System (ADS)

    Rajawat, Roopendra Singh; Sengupta, Sudip; Kaw, Predhiman K.

    2016-10-01

    A numerical study of evolution of relativistic electron current beam in a cold homogeneous plasma with immobile ions has been carried out using one dimensional electrostatic relativistic particle-in-cell code. It is found that the beam current when longitudinally perturbed by imposing a relativistically intense wave, diminishes with time due to phase mixing effects, arising because of spatial variation of relativistic mass. Studies have been conducted for various flow velocities (v0 / c) and relativistic intensities (eE0/mωpe c ) of the perturbed wave. Rate of decay of current decreases with increasing flow velocity for a fixed (eE0/mωpe c ); and for a given initial current the final magnitude of current decreases with increasing relativistic intensity of the perturbed wave.

  14. A Four Channel Beam Current Monitor Data Acquisition System Using Embedded Processors

    SciTech Connect

    Wheat, Jr., Robert Mitchell; Dalmas, Dale A.; Dale, Gregory E.

    2015-08-11

    Data acquisition from multiple beam current monitors is required for electron accelerator production of Mo-99. A two channel system capable of recording data from two beam current monitors has been developed, is currently in use, and is discussed below. The development of a cost-effective method of extending this system to more than two channels and integrating of these measurements into an accelerator control system is the main focus of this report. Data from these current monitors is digitized, processed, and stored by a digital data acquisition system. Limitations and drawbacks with the currently deployed digital data acquisition system have been identified as have been potential solutions, or at least improvements, to these problems. This report will discuss and document the efforts we've made in improving the flexibility and lowering the cost of the data acquisition system while maintaining the minimum requirements.

  15. Demonstration of electronic pattern switching and 10x pattern demagnification in a maskless micro-ion beam reduction lithography system

    NASA Astrophysics Data System (ADS)

    Ngo, V. V.; Akker, B.; Leung, K. N.; Noh, I.; Scott, K. L.

    2002-05-01

    A proof-of-principle ion projection lithography (IPL) system called Maskless Micro-ion beam Reduction Lithography (MMRL) has been developed and tested at the Lawrence Berkeley National Laboratory (LBNL) for future integrated circuits (ICs) manufacturing and thin film media patterning. This MMRL system is aimed at completely eliminating the first stage of the conventional IPL system that contains the complicated beam optics design in front of the stencil mask and the mask itself. It consists of a multicusp RF plasma generator, a multi-beamlet pattern generator, and an all-electrostatic ion optical column. Results from ion beam exposures on PMMA and Shipley UVII-HS resists using 75 keV H+ are presented in this paper. Proof-of-principle electronic pattern switching together with 10x reduction ion optics (using a pattern generator made of nine 50-(micro)m switchable apertures) has been performed and is reported in this paper. In addition, the fabrication of a micro-fabricated pattern generator on an SOI membrane is also presented.

  16. Application of lateral photovoltage towards contactless light beam induced current measurements and its dependence on the finite beam size

    SciTech Connect

    Abhale, Atul Prakash; Rao, K. S. R. Koteswara

    2014-07-15

    The nature of the signal due to light beam induced current (LBIC) at the remote contacts is verified as a lateral photovoltage for non-uniformly illuminated planar p-n junction devices; simulation and experimental results are presented. The limitations imposed by the ohmic contacts are successfully overcome by the introduction of capacitively coupled remote contacts, which yield similar results without any significant loss in the estimated material and device parameters. It is observed that the LBIC measurements introduce artefacts such as shift in peak position with increasing laser power. Simulation of LBIC signal as a function of characteristic length L{sub c} of photo-generated carriers and for different beam diameters has resulted in the observed peak shifts, thus attributed to the finite size of the beam. Further, the idea of capacitively coupled contacts has been extended to contactless measurements using pressure contacts with an oxidized aluminium electrodes. This technique avoids the contagious sample processing steps, which may introduce unintentional defects and contaminants into the material and devices under observation. Thus, we present here, the remote contact LBIC as a practically non-destructive tool in the evaluation of device parameters and welcome its use during fabrication steps.

  17. Methods of optical diagnostics of electron-positron beams and interaction between plasma and high-current electron beam

    NASA Astrophysics Data System (ADS)

    Vyacheslavov, L. N.; Ivantsivskii, M. V.; Meshkov, O. I.; Popov, S. S.; Smaluk, V. V.

    2012-03-01

    Optical diagnostics is widely used, both in plasma-physics experiments and in measuring parameters of electron and positron beams in accelerators. In doing so, the approaches with the same methodological base are often applied, which is explained by similarity of certain properties of objects under study despite the fact that these fields of physics are absolutely specific and require using the specialized techniques. The possibility of close contacts and cooperation among scientists concerned with similar problems in different fields of physics contributes to the fruitful exchange of ideas and helps to overcome these problems. It is especially characteristic of the Budker Institute of Nuclear Physics, Siberian Branch of Russian Academy of Sciences, which is famous for pioneering works in the field of electron-positron colliders and controlled thermonuclear fusion. The first part of this paper presents a review of optical diagnostics of the stationary beam parameters in cyclic accelerators of electrons and positrons. The only techniques considered are those that became the recognized tools at colliders and storage rings of the latest generation, without which the routine operation of the facility is difficult to imagine. The second part of the paper describes optical diagnostics used in experiments of heating the plasma by a high-current electron beam.

  18. Self-deformation in a direct current driven helium jet micro discharge

    SciTech Connect

    Xu, S. F.; Zhong, X. X.

    2016-01-15

    We report on the experimental observation of three dimensional self-deformation in an atmospheric micro discharge of the helium microjet through a tube into the ambient air upon a water electrode. The geometry of the discharge system is axial symmetric. While decreasing the discharge current, three dimensional collective motion of plasma filaments is directly observed. The three dimensional configuration of the discharge self changed from an axial symmetrical horn to a rectangular horn when the water acts as a cathode.

  19. MicroRNAs as Biomarkers for Psychiatric Conditions: A Review of Current Research

    PubMed Central

    Hussain, Mariyah; Sreeram, Venkatesh

    2017-01-01

    Neural-derived exosomes can be used as diagnostic markers to screen for various psychiatric conditions. These intravenously injected exosomes carry the potential to cross the blood brain barrier and deliver miRNA molecules specifically to neurons, microglia, and oligodendrocytes in the brain, resulting in specific gene knockdown. Here the authors review and discuss the current research on microRNA molecules and the therapeutic roles they may potentially play in treating depression, bipolar disorder, and schizophrenia. PMID:28386521

  20. Correlative micro-diffraction and differential phase contrast study of mean inner potential and subtle beam-specimen interaction.

    PubMed

    Wu, Mingjian; Spiecker, Erdmann

    2017-02-02

    We present a correlative micro-diffraction and differential phase contrast (DPC) study within scanning transmission electron microscopy (STEM) on the determination of mean inner potential (MIP) and explain the origin of subtle beam-specimen interactions at the edge of wedge-shaped crystals using both experiment and simulation. Our measurement of MIP of Si and GaAs resulted in 12.48 ± 0.22 V and 14.15 ± 0.22 V, respectively, from directly evaluating beam refraction in micro-diffraction mode. DPC-STEM measurements gave very similar values. Fresnel fringes within the diffraction disk resulting from interaction of the highly coherent electron beam with the aperture are observed and a numerical simulation scheme is implemented to reproduce the effect of the specimen on the fringe pattern. Perfect agreement between experiment and simulation has been achieved in terms of subtle displacements of the fringes upon approaching the sample edge with the electron probe. The existence of the fringes has minor effect on the DPC-STEM signal, which is well below the noise level of our setup at practically reasonable acquisition times. We suggest the possibility to perform pseudo-contactless probing of weak potential differences in beam sensitive samples by evaluating the subtle displacements of Fresnel fringes quantitatively.

  1. Upward electron beams measured by DE-1: A primary source of dayside region-1 Birkeland currents

    SciTech Connect

    Burch, J.L.; Reiff, P.H.; Sugiura, M.

    1983-08-01

    Measurements made by the High Altitude Plasma Instrument on DE-1 have shown that intense upward electron beams with energies from roughly-equal20 eV to roughly-equal200 eV are a common feature of the region just equatorward of the morning-side polar cusp. Computations of the currents carried by these beams and by the precipitating cusp electrons show excellent agreement with the simultaneous DE-1 magnetometer measurements for both upward and downward Birkeland currents. The data indicate that cold ionospheric electrons, which carry the downward region-1 Birkeland currents on the morning side, are accelerated upward by potential drops of a few tens of eV at altitudes of several thousand kilometers. This acceleration process allows spacecraft above those altitudes to measure routinely the charge carriers of both downward and upward current systems.

  2. Upward electron beams measured by DE-1 - A primary source of dayside region-1 Birkeland currents

    NASA Astrophysics Data System (ADS)

    Burch, J. L.; Reiff, P. H.; Sugiura, M.

    1983-08-01

    Measurements made by the High Altitude Plasma Instrument on DE-1 have shown that intense upward electron beams with energies from about 20 eV to about 200 eV are a common feature of the region just equatorward of the morning-side polar cusp. Computations of the currents carried by these beams and by the precipitating cusp electrons show excellent agreement with the simultaneous DE-1 magnetometer measurements for both upward and downward Birkeland currents. The data indicate that cold ionospheric electrons, which carry the downward region-1 Birkeland currents on the morning side, are accelerated upward by potential drops of a few tens of eV at altitudes of several thousand kilometers. This acceleration process allows spacecraft above those altitudes to measure routinely the charge carriers of both downward and upward current systems.

  3. Upward electron beams measured by DE-1 - A primary source of dayside region-1 Birkeland currents

    NASA Technical Reports Server (NTRS)

    Burch, J. L.; Reiff, P. H.; Sugiura, M.

    1983-01-01

    Measurements made by the High Altitude Plasma Instrument on DE-1 have shown that intense upward electron beams with energies from about 20 eV to about 200 eV are a common feature of the region just equatorward of the morning-side polar cusp. Computations of the currents carried by these beams and by the precipitating cusp electrons show excellent agreement with the simultaneous DE-1 magnetometer measurements for both upward and downward Birkeland currents. The data indicate that cold ionospheric electrons, which carry the downward region-1 Birkeland currents on the morning side, are accelerated upward by potential drops of a few tens of eV at altitudes of several thousand kilometers. This acceleration process allows spacecraft above those altitudes to measure routinely the charge carriers of both downward and upward current systems.

  4. Study of transients in the formation of heavy-current nanosecond electron beams

    NASA Astrophysics Data System (ADS)

    Pegel', I. V.

    1996-12-01

    Results are presented from experimental and numerical studies of the spatial and temporal microstructure of a relativistic heavy-current electron beam of nanosecond duration. The beam is formed in a magnetically insulated coaxial diode with an edge-emitting cathode. Microcurrent oscillations and azimuthal nonuniformity of the beam are seen, the scale of the latter depending on the maximum cyclotron radius of the electrons. Two- and three-dimensional numerical calculations performed by the macroparticle method show that space-charge oscillations near the cathode produce these phenomena even in the case of a uniform emission surface. It is shown that the increase in the full current of the beam that occurs during the pulse in a weak magnetic field is connected with the gradual propagation of emission to the cylindrical outside surface of the cathode. A study is made of the effect of the discreteness of the emission surface on the impedance and current of the vacuum diode. The linear increase seen in current during the pulse with a small number of emission centers is attributed to an increase in their size as a result of expansion of the cathode plasma.

  5. Severe Self-induced Beam Distortion in Laboratory Simulated Laser Propagation at 10.6 micro.

    PubMed

    Buser, R G; Rohde, R S

    1973-02-01

    Precision irradiance profiles have been determined for horizontally slewing high power laser beams through stationary absorbing gaseous media for the case of strong beam-medium interaction coupled with strong heating. Results are compared with the predictions of existing theoretical models concerning thermally induced lens effects in the presence of cross winds. Bending of the beam into the wind by beam slewing and intensification is found in reasonable agreement with the theory; for the observed overall beam spread, induced flow, turbulent tail, and concomitant beam breakup, no satisfactory theoretical treatment is available.

  6. Performance evaluation of high-temperature superconducting current leads for micro-SMES systems

    NASA Astrophysics Data System (ADS)

    Niemann, R. C.; Cha, Y. S.; Hull, J. R.; Buckles, W. E.; Weber, B. R.; Yang, S. T.

    As part of the US Department of Energy's Superconductivity Technology Program, Argonne National Laboratory and Superconductivity, Inc., are developing high-temperature superconductor (HTS) current leads for application to micro-superconducting magnetic energy storage systems. Two 1500-A HTS leads have been designed and constructed. The performance of the current lead assemblies is being evaluated in a zero-magnetic-field test program that includes assembly procedures, tooling, and quality assurance; thermal and electrical performance; and flow and mechanical characteristics. Results of evaluations performed to data are presented.

  7. Current neutralization and focusing of intense ion beams with a plasma-filled solenoidal lens. I

    SciTech Connect

    Oliver, B.V.; Sudan, R.N.

    1996-12-01

    The response of the magnetized plasma in an axisymmetric, plasma-filled, solenoidal magnetic lens, to intense light ion beam injection is studied. The lens plasma fill is modeled as an inertialess, resistive, electron magnetohydrodynamic (EMHD) fluid since characteristic beam times {tau} satisfy 2{pi}/{omega}{sub {ital pe}},2{pi}/{Omega}{sub {ital e}}{lt}{tau}{le}2{pi}/{Omega}{sub {ital i}} ({omega}{sub {ital pe}} is the electron plasma frequency and {Omega}{sub {ital e},{ital i}} are the electron, ion gyrofrequencies). When the electron collisionality satisfies {nu}{sub {ital e}}{lt}{Omega}{sub {ital e}}, the linear plasma response is determined by whistler wave dynamics. In this case, current neutralization of the beam is reduced on the time scale for whistler wave transit across the beam. The transit time is inversely proportional to the electron density and proportional to the angle of incidence of the beam with respect to the applied solenoidal field. In the collisional regime ({nu}{sub {ital e}}{gt}{Omega}{sub {ital e}}) the plasma return currents decay on the normal diffusive time scale determined by the conductivity. The analysis is supported by two-and-one-half dimensional hybrid particle-in-cell simulations. {copyright} {ital 1996 American Institute of Physics.}

  8. Spatially-Resolved Beam Current and Charge-State Distributions for the NEXT Ion Engine

    NASA Technical Reports Server (NTRS)

    Pollard, James E.; Diamant, Kevin D.; Crofton, Mark W.; Patterson, Michael J.; Soulas, George C.

    2010-01-01

    Plume characterization tests with the 36-cm NEXT ion engine are being performed at The Aerospace Corporation using engineering-model and prototype-model thrusters. We have examined the beam current density and xenon charge-state distribution as functions of position on the accel grid. To measure the current density ratio j++/j+, a collimated Eprobe was rotated through the plume with the probe oriented normal to the accel electrode surface at a distance of 82 cm. The beam current density jb versus radial position was measured with a miniature planar probe at 3 cm from the accel. Combining the j++/j+ and jb data yielded the ratio of total Xe+2 current to total Xe+1 current (J++/J+) at forty operating points in the standard throttle table. The production of Xe+2 and Xe+3 was measured as a function of propellant utilization to support performance and lifetime predictions for an extended throttle table. The angular dependence of jb was measured at intermediate and far-field distances to assist with plume modeling and to evaluate the thrust loss due to beam divergence. Thrust correction factors were derived from the total doubles-to-singles current ratio and from the far-field divergence data

  9. Beam extraction and high stability operation of high current electron cyclotron resonance proton ion source

    SciTech Connect

    Roychowdhury, P. Mishra, L.; Kewlani, H.; Mittal, K. C.; Patil, D. S.

    2014-03-15

    A high current electron cyclotron resonance proton ion source is designed and developed for the low energy high intensity proton accelerator at Bhabha Atomic Research Centre. The plasma discharge in the ion source is stabilized by minimizing the reflected microwave power using four stub auto tuner and magnetic field. The optimization of extraction geometry is performed using PBGUNS code by varying the aperture, shape, accelerating gap, and the potential on the electrodes. While operating the source, it was found that the two layered microwave window (6 mm quartz plate and 2 mm boron nitride plate) was damaged (a fine hole was drilled) by the back-streaming electrons after continuous operation of the source for 3 h at beam current of 20–40 mA. The microwave window was then shifted from the line of sight of the back-streaming electrons and located after the water-cooled H-plane bend. In this configuration the stable operation of the high current ion source for several hours is achieved. The ion beam is extracted from the source by biasing plasma electrode, puller electrode, and ground electrode to +10 to +50 kV, −2 to −4 kV, and 0 kV, respectively. The total ion beam current of 30–40 mA is recorded on Faraday cup at 40 keV of beam energy at 600–1000 W of microwave power, 800–1000 G axial magnetic field and (1.2–3.9) × 10{sup −3} mbar of neutral hydrogen gas pressure in the plasma chamber. The dependence of beam current on extraction voltage, microwave power, and gas pressure is investigated in the range of operation of the ion source.

  10. Beam extraction and high stability operation of high current electron cyclotron resonance proton ion source.

    PubMed

    Roychowdhury, P; Mishra, L; Kewlani, H; Patil, D S; Mittal, K C

    2014-03-01

    A high current electron cyclotron resonance proton ion source is designed and developed for the low energy high intensity proton accelerator at Bhabha Atomic Research Centre. The plasma discharge in the ion source is stabilized by minimizing the reflected microwave power using four stub auto tuner and magnetic field. The optimization of extraction geometry is performed using PBGUNS code by varying the aperture, shape, accelerating gap, and the potential on the electrodes. While operating the source, it was found that the two layered microwave window (6 mm quartz plate and 2 mm boron nitride plate) was damaged (a fine hole was drilled) by the back-streaming electrons after continuous operation of the source for 3 h at beam current of 20-40 mA. The microwave window was then shifted from the line of sight of the back-streaming electrons and located after the water-cooled H-plane bend. In this configuration the stable operation of the high current ion source for several hours is achieved. The ion beam is extracted from the source by biasing plasma electrode, puller electrode, and ground electrode to +10 to +50 kV, -2 to -4 kV, and 0 kV, respectively. The total ion beam current of 30-40 mA is recorded on Faraday cup at 40 keV of beam energy at 600-1000 W of microwave power, 800-1000 G axial magnetic field and (1.2-3.9) × 10(-3) mbar of neutral hydrogen gas pressure in the plasma chamber. The dependence of beam current on extraction voltage, microwave power, and gas pressure is investigated in the range of operation of the ion source.

  11. Beam Filamentation Instability of Interacting Current Sheets in Striped Relativistic Winds: The Origin of Low Sigma?

    NASA Astrophysics Data System (ADS)

    Arons, Jonathan

    Several lines of evidence suggest that relativistic winds from pulsars have flow energy dominated by kinetic energy at their termination, even though they emerge from the light cylinder as Poynting flux dominated flows. The wind sources are oblique rotators, thus the winds are "striped" - composed of interleaved sectors of oppositely directed B in a wide sector of latitude around the rotational equator. The electric current in the sheets separating the oppositely directed magnetic fields of the stripes, which provide the star's electric return current, is composed of a high energy particle beam, propagating across the magnetic field in an almost unmagnetized channel of thickness comparable to the particles' formal Larmor radius. The beams in neighboring sheets have opposite propagation directions, and interact across the stripes through the long range electromagnetic field. Thus the beams are subject to an electromagnetic shear instability which has strong kinship to Weibel beam filamentation instabilities in unmagnetized plasmas. I outline the physics of this instability, apply it to the pair dominated winds from pulsars, both in the case when the return current is composed of ions or high energy positrons (angle between the angular velocity and the magnetic moment less than 90 degrees, an "acute" pulsar) and also in the electron beam return current case (angle between the angular velocity and the magnetic moment greater than 90 degrees, an "obtuse" pulsar). I argue that the instability saturates through magnetic trapping, which leads to the appearance of an anomalous resistance in the pulsar circuit, and show that this resistance can account for the reduction of the striped component of the winds' magnetic fields, through broadening of the current layers until they merge and the stripes disappear. I discuss some possible observational consequences of this magnetic dissipation in the apparently dark region between the light cylinder and the winds' termination

  12. Proton beam therapy: clinical utility and current status in prostate cancer.

    PubMed

    Yamoah, Kosj; Johnstone, Peter As

    2016-01-01

    Proton beam therapy has recently become available to a broader population base. There remains much controversy about its routine use in prostate cancer. We provide an analysis of the existing literature regarding efficacy and toxicity of the technique. Currently, the use of proton beam therapy for prostate cancer is largely dependent on continued reimbursement for the practice. While there are potential benefits supporting the use of protons in prostate cancer, the low risk of toxicity using existing techniques and the high cost of protons contribute to lower the value of the technique.

  13. Simulation of 10 A electron beam formation and collection for a high current EBIS

    SciTech Connect

    Kponou, A.; Beebe, E.; Pikin, A.; Kuznetsov, G.; Batazova, M.; Tiunov, M.

    1997-11-01

    Development of an Electron Beam Ion Source (EBIS) for the Relativistic Heavy Ion Collider (RHIC) at BNL requires operating with a 10 A electron beam, which is approximately an order of magnitude higher current than in any existing EBIS device. A test stand is presently being designed and constructed where EBIS components will be twisted. It will be reported in a separate paper at this Conference. The design of the 10 A electron gun, drift tubes and electron collector requires extensive computer simulations. Calculations have been performed at Novosibirsk and BNL using two different programs, SAM and EGUN. Results of these simulations will be presented.

  14. Proton beam therapy: clinical utility and current status in prostate cancer

    PubMed Central

    Yamoah, Kosj; Johnstone, Peter AS

    2016-01-01

    Proton beam therapy has recently become available to a broader population base. There remains much controversy about its routine use in prostate cancer. We provide an analysis of the existing literature regarding efficacy and toxicity of the technique. Currently, the use of proton beam therapy for prostate cancer is largely dependent on continued reimbursement for the practice. While there are potential benefits supporting the use of protons in prostate cancer, the low risk of toxicity using existing techniques and the high cost of protons contribute to lower the value of the technique. PMID:27695349

  15. The inhibitory action of cyclic AMP on responses to carbachol dependent on calcium stores in rat gastric smooth muscle.

    PubMed Central

    Ohta, T; Ito, S; Noto, T; Tachibana, R; Nakazato, Y; Ohga, A

    1992-01-01

    1. The effects of cyclic AMP on contraction and Ca(2+)-activated K+ currents induced by carbachol (CCh), caffeine and inositol 1,4,5-trisphosphate (InsP3) were examined in intact and skinned smooth muscle fibres and in whole-cell voltage-clamped smooth muscle cells of the rat stomach. Intracellular Ca2+ level, [Ca2+]i, was monitored in intact muscle fibres loaded with Fura-2. 2. In intact muscle fibres, dibutyryl cyclic AMP, 8-bromo-cyclic AMP and forskolin inhibited a phasic contraction induced by CCh (100 microM) much more extensively than that induced by caffeine (30 mM) in Ca(2+)-free solution containing 2 mM-EGTA. A rise in [Ca2+]i evoked by CCh was also reduced by dibutyryl cyclic AMP. 3. In skinned muscle fibres, InsP3 (40 microM) produced a contraction of amplitude similar to that evoked by caffeine (30 mM) in Ca(2+)-free solution containing 0.05 mM-EGTA. Cyclic AMP suppressed the InsP3-induced contraction to a much greater extent than that induced by caffeine. 4. In cells voltage-clamped at 0 mV, CCh (100 microM) evoked a transient Ca(2+)-activated outward K+ current in 61% of cells tested. After wash-out of CCh, caffeine (10 mM) evoked a similar K+ current in all cells. In cells loaded with cyclic AMP (100 microM), the percentage of cells responding to CCh was reduced to 26% and the magnitude of current response tended to decrease. Cyclic AMP caused a small increase in the caffeine-induced K+ current. 5. An outward current was elicited immediately after the patch membrane was ruptured at a holding potential of 0 mV, using a patch pipette containing InsP3 (40 microM), in 76% of cells tested. In cells treated with dibutyryl cyclic AMP, the percentage of cells responding to InsP3 was reduced to 50% and the magnitude of current response tended to decrease. 6. In intact muscle fibres loaded with Fura-2, the relationship between [Ca2+]i and tension development shifted to the right in the presence of dibutyryl cyclic AMP. In skinned muscle fibres, cyclic AMP

  16. Issues concerning high current lower energy electron beams required for ion cooling between EBIS LINAC and booster

    SciTech Connect

    Hershcovitch,A.

    2009-03-01

    Some issues, regarding a low energy high current electron beam that will be needed for electron beam cooling to reduce momentum of gold ions exiting the EBIS LINAC before injection into the booster, are examined. Options for propagating such an electron beam, as well as the effect of neutralizing background plasma on electron and ion beam parameters are calculated. Computations and some experimental data indicate that none of these issues is a show stopper.

  17. Removing Beam Current Artifacts in Helium Ion Microscopy: A Comparison of Image Processing Techniques.

    PubMed

    Barlow, Anders J; Portoles, Jose F; Sano, Naoko; Cumpson, Peter J

    2016-10-01

    The development of the helium ion microscope (HIM) enables the imaging of both hard, inorganic materials and soft, organic or biological materials. Advantages include outstanding topographical contrast, superior resolution down to <0.5 nm at high magnification, high depth of field, and no need for conductive coatings. The instrument relies on helium atom adsorption and ionization at a cryogenically cooled tip that is atomically sharp. Under ideal conditions this arrangement provides a beam of ions that is stable for days to weeks, with beam currents in the order of picoamperes. Over time, however, this stability is lost as gaseous contamination builds up in the source region, leading to adsorbed atoms of species other than helium, which ultimately results in beam current fluctuations. This manifests itself as horizontal stripe artifacts in HIM images. We investigate post-processing methods to remove these artifacts from HIM images, such as median filtering, Gaussian blurring, fast Fourier transforms, and principal component analysis. We arrive at a simple method for completely removing beam current fluctuation effects from HIM images while maintaining the full integrity of the information within the image.

  18. Detection of cyclic di-AMP using a competitive ELISA with a unique pneumococcal cyclic di-AMP binding protein

    PubMed Central

    Underwood, Adam J.; Zhang, Yang; Metzger, Dennis W.; Bai, Guangchun

    2014-01-01

    Cyclic di-AMP (c-di-AMP) is a signaling molecule that has been shown to play important roles in bacterial physiology and infections. Currently, c-di-AMP detection and quantification relies mostly on the use of high-performance liquid chromatography (HPLC) or liquid chromatography-mass spectrometry (LC-MS). In this study, a competitive enzyme-linked immunosorbent assay (ELISA) for the quantification of c-di-AMP was developed, which utilizes a novel pneumococcal c-di-AMP binding protein (CabP) and a newly commercialized c-di-AMP derivative. With this new method, c-di-AMP concentrations in biological samples can be quickly and accurately quantified. Furthermore, this assay is much more efficient than current methods as it requires less overall cost and training while processing many samples at once. Therefore, this assay can be extensively used in research into c-di-AMP signaling. PMID:25239824

  19. Transdifferentiation via transcription factors or microRNAs: Current status and perspective.

    PubMed

    Wang, Huan; Li, Xiao; Gao, Shutao; Sun, Xuying; Fang, Huang

    2015-01-01

    Transdifferentiation as a new approach for obtaining the ideal cells for transplantation has gradually become a hot research topic. Compared with the induced pluripotent stem cells technique, transdifferentiation may have better efficiency and safety. Although the mechanism of transdifferentiation is still unknown, many studies have achieved transformation of one cell type to another through transcription factors or microRNA. The current major strategy for transdifferentiation is via transcription factors; however, there are some safety issues with the use of transcription factors. In contrast, microRNA as a novel tool for inducing transdifferentiation through post-transcriptional regulation may be more safe and efficient. In addition, the present transdifferentiation strategies involve obtaining the terminal cell directly, so the amount of cells produced may not be sufficient and they may have low capacity for cell immigration and integration. Therefore, an indirect transdifferentiation strategy for producing unipotent cells is ideal as it can preserve the proliferation capacity and differentiation pathway.

  20. High energy micro electron beam generation using chirped laser pulse in the presence of an axial magnetic field

    SciTech Connect

    Akou, H. Hamedi, M.

    2015-10-15

    In this paper, the generation of high-quality and high-energy micro electron beam in vacuum by a chirped Gaussian laser pulse in the presence of an axial magnetic field is numerically investigated. The features of energy and angular spectra, emittances, and position distribution of electron beam are compared in two cases, i.e., in the presence and absence of an external magnetic field. The electron beam is accelerated with higher energy and qualified in spatial distribution in the presence of the magnetic field. The presence of an axial magnetic field improves electron beam spatial quality as well as its gained energy through keeping the electron motion parallel to the direction of propagation for longer distances. It has been found that a 64 μm electron bunch with about MeV initial energy becomes a 20 μm electron beam with high energy of the order of GeV, after interacting with a laser pulse in the presence of an external magnetic field.

  1. AFM nano-plough planar YBCO micro-bridges: critical currents and magnetic field effects.

    PubMed

    Elkaseh, A A O; Perold, W J; Srinivasu, V V

    2010-10-01

    The critical current (Ic) of YBa2Cu3O7-x (YBCO) AFM plough micro-constrictions is measured as a function of temperature, width and the magnetic flux density (B), which was applied perpendicular to the YBCO ab-plane and surface of the bridges. C-axis oriented thin films of YBa2Cu3O7-x were deposited on MgO substrates using an inverted cylindrical magnetron (ICM) sputtering technique. The films were then patterned into 8-10 micron size strips, using standard photolithography and dry etching processes. Micro-bridges with widths between 1.9 microm to 4.1 microm were fabricated by using atomic force microscope (AFM) nanolithography techniques. Critical current versus temperature data shows a straight-line behavior, which is typical of constriction type Josephson junctions. The Ic versus B characteristics exhibited a modulation, and a suppression of the critical current of up to 84%. It was also found that the critical current increases with increasing constriction width.

  2. Absolute Current Calibration of 1$\\mu$A CW Electron Beam

    SciTech Connect

    Arne Freyberger; Mike Bevins; Anthony Day; Arunava Saha; Stephanie Slachtouski; Ronald Gilman; Pavel Degtiarenko

    2005-06-01

    The future experimental program at Jefferson Lab requires an absolute current calibration of a 1 {mu}A CW electron beam to better than 1% accuracy. This paper presents the mechanical and electrical design of a Tungsten calorimeter that is being constructed to provide an accurate measurement of the deposited energy. The energy is determined by measuring the change in temperature after beam exposure. Knowledge of the beam energy then yields number of electrons stopped by the calorimeter during the exposure. Simulations show that the energy lost due to electromagnetic and hadronic particle losses are the dominant uncertainty. Details of the precision thermometry and calibration, mechanical design, thermal simulations and simulations will be presented.

  3. Absolute Current Calibrations of 1muA CW Electron Beam

    SciTech Connect

    A. Freyberger, M.E. Bevins, A.R. Day, P. Degtiarenko, A. Saha, S. Slachtouski, R. Gilman

    2005-06-06

    The future experimental program at Jefferson Lab requires an absolute current calibration of a 1{mu}A CW electron beam to better than 1% accuracy. This paper presents the mechanical and electrical design of a Tungsten calorimeter that is being constructed to provide an accurate measurement of the deposited energy. The energy is determined by measuring the change in temperature after beam exposure. Knowledge of the beam energy then yields number of electrons stopped by the calorimeter during the exposure. Simulations show that the energy losses due to electromagnetic and hadronic losses are the dominant uncertainty. Details of the precision thermometry and calibration, mechanical design, thermal simulations and GEANT simulations will be presented.

  4. A high-current microwave ion source with permanent magnet and its beam emittance measurement

    SciTech Connect

    Yao Zeen; Tan Xinjian; Du Hongxin; Luo Ben; Liu Zhanwen

    2008-07-15

    The progress of a 2.45 GHz high-current microwave ion source with permanent magnet for T(d,n){sup 4}He reaction neutron generator is reported in this paper. At 600 W microwave power and 22 kV extraction voltage, 90 mA peak hydrogen ion beam is extracted from a single aperture of 6 mm diameter. The beam emittance is measured using a simplified pepper-pot method. The (x,x{sup '}) emittance and the (y,y{sup '}) emittance for 14 keV hydrogen ion beam are 55.3{pi} and 58.2{pi} mm mrad, respectively. The normalized emittances are 0.302{pi} and 0.317{pi} mm mrad, respectively.

  5. Clinical Trials Involving Biphasic Pulsed Current, MicroCurrent, and/or Low-Intensity Direct Current.

    PubMed

    Houghton, Pamela E

    2014-02-01

    Significance: This invited critical review will summarize an expansive body of literature regarding electrical stimulation (ES) and wound healing. Several clinical reports have been published in which ES has been evaluated as a therapy to speed the closure of chronic wounds. Different forms of ES have been applied in varying ways and described using inconsistent terminology by researchers and clinicians around the world. It is important to compile this research and to critically appraise the findings so that clinicians who are not familiar with this field can interpret the research. Recent Advances: More recently, ES has been delivered at subsensory levels (termed microcurrent in this review) using very small electrical devices contained within wound dressing. While these newer technologies have obvious technical advances, what research has been published to date about these new devices has not produced findings that suggest this form of ES can accelerate wound closure. Critical Issues: Reviewing a collection of published reports on this subject reveals that not all forms of ES produce beneficial results. Rather, only certain ES protocols such as monophasic pulsed current applied to the wound and biphasic pulsed current current that is applied for 2 h daily to periulcer skin at intensities which produce motor responses have consistently demonstrated positive results. Future Directions: Optimal stimulus parameters and treatment schedule for ES used to treat chronic wounds need to be determined. Researchers publishing in this field should provide detailed information about their ES treatment protocol and use a similar terminology to describe the ES waveform and stimulus parameters.

  6. Bolt beam propagation analysis

    NASA Astrophysics Data System (ADS)

    Shokair, I. R.

    BOLT (Beam on Laser Technology) is a rocket experiment to demonstrate electron beam propagation on a laser ionized plasma channel across the geomagnetic field in the ion focused regime (IFR). The beam parameters for BOLT are: beam current I(sub b) = 100 Amps, beam energy of 1--1.5 MeV (gamma =3-4), and a Gaussian beam and channel of radii r(sub b) = r(sub c) = 1.5 cm. The N+1 ionization scheme is used to ionize atomic oxygen in the upper atmosphere. This scheme utilizes 130 nm light plus three IR lasers to excite and then ionize atomic oxygen. The limiting factor for the channel strength is the energy of the 130 nm laser, which is assumed to be 1.6 mJ for BOLT. At a fixed laser energy and altitude (fixing the density of atomic oxygen), the range can be varied by adjusting the laser tuning, resulting in a neutralization fraction axial profile of the form: f(z) = f(sub 0) e(exp minus z)/R, where R is the range. In this paper we consider the propagation of the BOLT beam and calculate the range of the electron beam taking into account the fact that the erosion rates (magnetic and inductive) vary with beam length as the beam and channel dynamically respond to sausage and hose instabilities.

  7. Off-axis Neutral Beam Current Drive for Advanced Scenario Development in DIII-D

    SciTech Connect

    Murakami, M; Park, J; Petty, C; Luce, T; Heidbrink, W; Osborne, T; Wade, M; Austin, M; Brooks, N; Budny, R; Challis, C; DeBoo, J; deGrassie, J; Ferron, J; Gohil, P; Hobirk, J; Holcomb, C; Hollmann, E; Hong, R; Hyatt, A; Lohr, J; Lanctot, M; Makowski, M; McCune, D; Politzer, P; Prater, R; John, H S; Suzuki, T; West, W; Unterberg, E; Van Zeeland, M; Yu, J

    2008-10-13

    Modification of the two existing DIII-D neutral beam lines is proposed to allow vertical steering to provide off-axis neutral beam current drive (NBCD) as far off-axis as half the plasma radius. New calculations indicate very good current drive with good localization off-axis as long as the toroidal magnetic field, B{sub T}, and the plasma current, I{sub p}, are in the same direction (for a beam steered downward). The effects of helicity can be large: e.g., ITER off-axis NBCD can be increased by more than 20% if the B{sub T} direction is reversed. This prediction has been tested by an off-axis NBCD experiment using reduced size plasmas that are vertically shifted with the existing NBI on DIII-D. The existence of off-axis NBCD is evident in sawtooth and internal inductance behavior. By shifting the plasma upward or downward, or by changing the sign of the toroidal field, measured off-axis NBCD profiles, determined from MSE data, are consistent with predicted differences (40%-45%) arising from the NBI orientation with respect to the magnetic field lines. Modification of the DIII-D NB system will strongly support scenario development for ITER and future tokamaks as well as providing flexible scientific tools for understanding transport, energetic particles and heating and current drive.

  8. Performance evaluation of high-temperature superconducting current leads for micro-SMES systems

    NASA Astrophysics Data System (ADS)

    Niemann, R. C.; Cha, Y. S.; Hull, J. R.; Buckles, W. E.; Weber, B. R.; Yang, S. T.

    As part of the U.S. Department of Energy's Superconductivity Technology Program, Argonne National Laboratory and Superconductivity, Inc., are developing high-temperature superconductor (HTS) current leads for application to micro-SMES systems. Two 1500-A HTS leads have been designed and constructed. A component performance evaluation program was conducted to confirm performance predictions and/or to qualify the design features for construction. The evaluations included HTS characteristics, demountable electrical connections, and heat intercept effectiveness. The performance of current lead assemblies is being evaluated in a zero-magnetic-field test program that included assembly procedures, tooling, and quality assurance; thermal and electrical performance; and flow and mechanical characteristics. The leads were installed in a liquid helium test cryostat and connected at their cold ends by a current jumper. The leads were heat intercepted with a cryocooler.

  9. Study of charge-sharing in MEDIPIX3 using a micro-focused synchrotron beam

    NASA Astrophysics Data System (ADS)

    Gimenez, E. N.; Ballabriga, R.; Campbell, M.; Horswell, I.; Llopart, X.; Marchal, J.; Sawhney, K. J. S.; Tartoni, N.; Turecek, D.

    2011-01-01

    X-ray photon-counting detectors consisting of a silicon pixel array sensor bump-bonded to a CMOS electronic readout chip offer several advantages over traditional X-ray detection technologies used for synchrotron applications. They offer high frame rate, dynamic range, count rate capability and signal-to-noise ratio. A survey of the requirements for future synchrotron detectors carried out at the Diamond Light Source synchrotron highlighted the needs for detectors with a pixel size of the order of 50μm. Reducing the pixel size leads to an increase of charge-sharing events between adjacent pixels and, therefore, to a degradation of the energy resolution and image quality of the detector. This effect was observed with MEDIPIX2, a photon-counting readout chip with a pixel size of 55μm. The lastest generation of the MEDIPIX family, MEDIPIX3, is designed to overcome this charge-sharing effect in an implemented readout operating mode referred to as Charge Summing Mode. MEDIPIX3 has the same pixel size as MEDIPIX2, but it is implemented in an 8-metal 0.13μm CMOS technology which enables increased functionality per pixel. The present work focuses on the study of the charge-sharing effect when the MEDIPIX3 is operated in Charge Summing Mode compared to the conventional readout mode, referred to as Single Pixel Mode. Tests of a standard silicon photodiode array bump-bonded to MEDIPIX3 were performed in beamline B16 at the Diamond Light Source synchrotron. A monochromatic micro-focused beam of 2.9μm x 2.2μm size at 15keV was used to scan a cluster of nine pixels in order to study the charge collection and X-ray count allocation process for each readout mode, Single Pixel Mode and Charge Summing Mode. The study showed that charge-shared events were eliminated when Medipix3 was operated in Charge Summing Mode.

  10. X-ray diagnostic for current density profiling relativistic electron beams in vacuum and gas

    SciTech Connect

    Slaughter, D.; Koppel, L.; Smith, J.

    1986-02-15

    An x-ray imaging technique has been studied for the purpose of observing the current density profile in a high-current relativistic electron beam (50 MeV, 10 kA). Calculations and measurements of energy spectra and intensities are in good agreement. Results indicate sufficient photon yield for pinhole imaging when the beam deposits a small part of its energy in high-Z gas or a thin high-Z foil. Characteristic L and K x-ray emission is not found not be a reliable technique due to strong L and K shell fluorescence in the presence of intense bremsstrahlung radiation. It is also found that at pressures on the order of one atmosphere, the density of energy deposition in a gas cell is too small to generate sufficient photon yield for time-resolved measurements.

  11. Reduction of beam current noise in the FNAL magnetron ion source

    SciTech Connect

    Bollinger, D. S. Karns, P. R. Tan, C. Y.

    2015-04-08

    The new FNAL Injector Line with a circular dimple magnetron ion source has been operational since December of 2012. Since the new injector came on line there have been variations in the H- beam current flattop observed near the downstream end of the Linac. Several different cathode geometries including a hollow cathode suggested by Dudnikov [1] were tried. Previous studies also showed that different mixtures of hydrogen and nitrogen had an effect on beam current noise [2]. We expanded on those studies by trying mixtures ranging from (0.25% nitrogen, 99.75% hydrogen) to (3% nitrogen, 97% hydrogen). The results of these studies in our test stand will be presented in this paper.

  12. Charged current disappearance measurements in the NuMI off-axis beam

    SciTech Connect

    R. H. Bernstein

    2003-09-25

    This article studies the potential of combining charged-current disappearance measurements of {nu}{sub {mu}} {yields} {nu}{sub {tau}} from MINOS and an off-axis beam. The author finds that the error on {Delta}m{sup 2} from a 100 kt-yr off-axis measurement is a few percent of itself. Further, the author found little improvement to an off-axis measurement by combining it with MINOS.

  13. Optimizing field patching in passively scattered proton therapy with the use of beam current modulation.

    PubMed

    Hill, Patrick M; Klein, Eric E; Bloch, Charles

    2013-08-21

    Treatment plans for patched-field proton therapy may not be clinically acceptable due to the dose heterogeneity introduced in the target when combining the dose distributions from two separate fields. MCNPX simulations were performed for various configurations of the Mevion S250 beamline to determine spread-out Bragg peak dose distributions and patched-field treatment plans delivered using a rotating modulator wheel to depths in the clinically relevant range between 5.0 and 30.0 cm. The dose non-uniformity (DNU) metric was defined as the difference between the maximum and minimum dose relative to the prescription observed in a patched dose distribution. The DNU was first evaluated for dose distributions from a standard delivery using constant beam current and combining through-field lateral dose profiles and with patch-field distal dose profiles. Patch-field distal dose profiles were then optimized using beam current modulation in an attempt to better complement the through-field lateral dose profiles when combined into a patched dose distribution. Using standard deliveries, DNU was 10% or less only when patching lateral profiles 12.5-17.5 cm deep. Significantly greater DNU was observed for patches outside of this range, at times exceeding 35%. Using optimized distal profiles, DNU was reduced to 10% or less for all lateral profiles deeper than 15.0 cm. Optimizing beam current modulation was found to create distal profiles with more gradual dose falloff than found in a standard delivery, allowing optimized distal dose distributions to sum more homogeneously with lateral dose distributions. The hot or cold spots that often appear in patched dose distributions from standard deliveries may therefore be mitigated by optimizing beam current. This method may also be applied to systems other than the Mevion system to further improve patched-field dose homogeneity.

  14. Experiments on current-driven three-dimensional ion sound turbulence. I - Return-current limited electron beam injection. II - Wave dynamics

    NASA Technical Reports Server (NTRS)

    Stenzel, R. L.

    1978-01-01

    Pulsed electron beam injection into a weakly collisional magnetized background plasma is investigated experimentally; properties of the electron beam and background plasma, as well as the low-frequency instabilities and wave dynamics, are discussed. The current of the injected beam closes via a field-aligned return current of background electrons. Through study of the frequency and wavenumber distribution, together with the electron distribution function, the low-frequency instabilities associated with the pulsed injection are identified as ion acoustic waves driven unstable by the return current. The frequency cut-off of the instabilities predicted from renormalized plasma turbulence theory, has been verified experimentally.

  15. Open-loop correction for an eddy current dominated beam-switching magnet

    SciTech Connect

    Koseki, K. Nakayama, H.; Tawada, M.

    2014-04-15

    A beam-switching magnet and the pulsed power supply it requires have been developed for the Japan Proton Accelerator Research Complex. To switch bunched proton beams, the dipole magnetic field must reach its maximum value within 40 ms. In addition, the field flatness should be less than 5 × 10{sup −4} to guide each bunched beam to the designed orbit. From a magnetic field measurement by using a long search coil, it was found that an eddy current in the thick endplates and laminated core disturbs the rise of the magnetic field. The eddy current also deteriorates the field flatness over the required flat-top period. The measured field flatness was 5 × 10{sup −3}. By using a double-exponential equation to approximate the measured magnetic field, a compensation pattern for the eddy current was calculated. The integrated magnetic field was measured while using the newly developed open-loop compensation system. A field flatness of less than 5 × 10{sup −4}, which is an acceptable value, was achieved.

  16. High-power Čerenkov microwave oscillators utilizing High-Current nanosecond Electron beams

    NASA Astrophysics Data System (ADS)

    Korovin, S. D.; Polevin, S. D.; Rostov, V. V.

    1996-12-01

    A short review is given of results obtained at the Institute of High-Current Electronics of the Siberian Branch of the Russian Academy of Sciences on generating high-power microwave radiation. Most of the research was devoted to a study of stimulated Čerenkov radiation from relativistic electron beams. It is shown that the efficiency of a relativistic 3-cm backward wave tube with a nonuniform coupling resistance can reach 35%. High-frequency radiation was discovered in the emission spectrum of the Čerenkov oscillators and it was shown that the nature of the radiation was associated with the stimulated scattering of low-frequency radiation by the relativistic electrons. Radiation with a power of 500 MW was obtained in the 8-mm wavelength range using a two-beam Čerenkov oscillator. High-current pulse-periodic nanosecond accelerators with a charging device utilizing a Tesla transformer were used in the experiments. The possibility was demonstrated of generating high-power microwave radiation with a pulse-repetition frequency of up to 100 Hz. An average power of ˜500 W was achieved from the relativistic oscillators. A relativistic backward wave tube with a high-current electron beam was used to make a prototype nanosecond radar device. Some of the results presented were obtained jointly with the Russian Academy of Sciences Institute of Applied Physics. Questions concerning multiwave Čerenkov interaction are not considered in this paper.

  17. Coherent Effects of High Current Beam in Project-X Linac

    SciTech Connect

    Sukhanov, A.; Lunin, A.; Yakovlev, V.; Gonin, I.; Khabiboulline, T.; Saini, A.; Solyak, N.; Yostrikov, A.

    2012-09-01

    Resonance excitation of longitudinal high order modes in superconducting RF structures of Project-X continuous wave linac is studied. We analyze regimes of operation of the linac with high beam current, which can be used to provide an intense muon source for the future Neutrino Factory or Muon Collider, and also important for the Accelerator-Driven Subcritical systems. We calculate power loss and associated heat load to the cryogenic system. Longitudinal emittance growth is estimated. We consider an alternative design of the elliptical cavity for the high energy part of the linac, which is more suitable for high current operation.

  18. Coherent Effects of High Current Beam in Project-X Linac

    SciTech Connect

    Sukhanov, Alexander; Yakovlev, Vyacheslav; Gonin, Ivan; Khabiboulline, Timergali; Lunin, Andrei; Saini, Arun; Solyak, Nikolay; Vostrikov, Alexander

    2013-04-01

    Resonance excitation of longitudinal high order modes in superconducting RF structures of Project-X continuous wave linac is studied. We analyze regimes of operation of the linac with high beam current, which can be used to provide an intense muon source for the future Neutrino Factory or Muon Collider, and also important for the Accelerator-Driven Subcritical systems. We calculate power loss and associated heat load to the cryogenic system. Longitudinal emittance growth is estimated. We consider an alternative design of the elliptical cavity for the high energy part of the linac, which is more suitable for high current operation.

  19. The use of Targeted MicroCurrent Therapy in postoperative pain management.

    PubMed

    Gabriel, Allen; Sobota, Rachel; Gialich, Shelby; Maxwell, G Patrick

    2013-01-01

    Effective postoperative analgesia is a prerequisite to enhance the recovery process and reduce morbidity. The use of local anesthetic techniques is well documented to be effective, but single-dose techniques (infiltration, peripheral blocks, neuraxial blocks) have been of limited value in major operations because of their short duration of analgesia. Recent advances in technology have led to the development of a noninvasive device, targeted MicroCurrent Therapy, which enhances postsurgical recovery by stimulating the body's natural healing process. This therapy transmits gentle, short bursts of electrical current targeted to the tissue cells at the surgical site. This article reviews recent clinical experience and evidence of this device in plastic and reconstructive surgery.

  20. High-temperature superconducting current leads for micro-SMES application

    NASA Astrophysics Data System (ADS)

    Niemann, R. C.; Cha, Y. S.; Hull, J. R.; Buckles, W. E.; Daugherty, M. A.; Weber, B. R.

    1994-07-01

    SMES is being applied on a microscale (1-10 MJ stored energy) to improve electrical power quality. A major portion of the SMES refrigeration load is for cooling the conventional (copper, vapor-cooled) current leads that transfer energy between the magnet and the power-conditioning equipment. The lead refrigeration load can be reduced significantly by the use of high-temperature superconductors (HTSs). An HTS current lead suitable for micro-SMES application has been designed. The lower stage of the lead employs HTSs. A transition between the lower stage and the conventional upper-stage lead is heat-intercepted by a cryocooler. Details of the design are presented. Construction and operating experiences are discussed.

  1. Amplification of current density modulation in a FEL with an infinite electron beam

    SciTech Connect

    Wang, G.; Litvinenko, V.N.; Webb, S.D.

    2011-03-28

    We show that the paraxial field equation for a free electron laser (FEL) in an infinitely wide electron beam with {kappa}-2 energy distribution can be reduced to a fourth ordinary differential equation (ODE). Its solution for arbitrary initial phase space density modulation has been derived in the wave-vector domain. For initial current modulation with Gaussian profile, close form solutions are obtained in space-time domain. In developing an analytical model for a FEL-based coherent electron cooling system, an infinite electron beam has been assumed for the modulation and correction processes. While the assumption has its limitation, it allows for an analytical close form solution to be obtained, which is essential for investigating the underlying scaling law, benchmarking the simulation codes and understanding the fundamental physics. 1D theory was previously applied to model a CeC FEL amplifier. However, the theory ignores diffraction effects and does not provide the transverse profile of the amplified electron density modulation. On the other hand, 3D theories developed for a finite electron beam usually have solutions expanded over infinite number of modes determined by the specific transverse boundary conditions. Unless the mode with the largest growth rate substantially dominates other modes, both evaluation and extracting scaling laws can be complicated. Furthermore, it is also preferable to have an analytical FEL model with assumptions consistent with the other two sections of a CeC system. Recently, we developed the FEL theory in an infinitely wide electron beam with {kappa}-1 (Lorentzian) energy distribution. Close form solutions have been obtained for the amplified current modulation initiated by an external electric field with various spatial-profiles. In this work, we extend the theory into {kappa}-2 energy distribution and study the evolution of current density induced by an initial density modulation.

  2. Current profile redistribution driven by neutral beam injection in a reversed-field pinch

    NASA Astrophysics Data System (ADS)

    Parke, E.; Anderson, J. K.; Brower, D. L.; Den Hartog, D. J.; Ding, W. X.; Johnson, C. A.; Lin, L.

    2016-05-01

    Neutral beam injection in reversed-field pinch (RFP) plasmas on the Madison Symmetric Torus [Dexter et al., Fusion Sci. Technol. 19, 131 (1991)] drives current redistribution with increased on-axis current density but negligible net current drive. Internal fluctuations correlated with tearing modes are observed on multiple diagnostics; the behavior of tearing mode correlated structures is consistent with flattening of the safety factor profile. The first application of a parametrized model for island flattening to temperature fluctuations in an RFP allows inferrence of rational surface locations for multiple tearing modes. The m = 1, n = 6 mode is observed to shift inward by 1.1 ± 0.6 cm with neutral beam injection. Tearing mode rational surface measurements provide a strong constraint for equilibrium reconstruction, with an estimated reduction of q0 by 5% and an increase in on-axis current density of 8% ± 5%. The inferred on-axis current drive is consistent with estimates of fast ion density using TRANSP [Goldston et al., J. Comput. Phys. 43, 61 (1981)].

  3. Determination of the ReA Electron Beam Ion Trap electron beam radius and current density with an X-ray pinhole camera.

    PubMed

    Baumann, Thomas M; Lapierre, Alain; Kittimanapun, Kritsada; Schwarz, Stefan; Leitner, Daniela; Bollen, Georg

    2014-07-01

    The Electron Beam Ion Trap (EBIT) of the National Superconducting Cyclotron Laboratory at Michigan State University is used as a charge booster and injector for the currently commissioned rare isotope re-accelerator facility ReA. This EBIT charge breeder is equipped with a unique superconducting magnet configuration, a combination of a solenoid and a pair of Helmholtz coils, allowing for a direct observation of the ion cloud while maintaining the advantages of a long ion trapping region. The current density of its electron beam is a key factor for efficient capture and fast charge breeding of continuously injected, short-lived isotope beams. It depends on the radius of the magnetically compressed electron beam. This radius is measured by imaging the highly charged ion cloud trapped within the electron beam with a pinhole camera, which is sensitive to X-rays emitted by the ions with photon energies between 2 keV and 10 keV. The 80%-radius of a cylindrical 800 mA electron beam with an energy of 15 keV is determined to be r(80%) = (212 ± 19)μm in a 4 T magnetic field. From this, a current density of j = (454 ± 83)A/cm(2) is derived. These results are in good agreement with electron beam trajectory simulations performed with TriComp and serve as a test for future electron gun design developments.

  4. Determination of the ReA Electron Beam Ion Trap electron beam radius and current density with an X-ray pinhole camera

    SciTech Connect

    Baumann, Thomas M. Lapierre, Alain Kittimanapun, Kritsada; Schwarz, Stefan; Leitner, Daniela; Bollen, Georg

    2014-07-15

    The Electron Beam Ion Trap (EBIT) of the National Superconducting Cyclotron Laboratory at Michigan State University is used as a charge booster and injector for the currently commissioned rare isotope re-accelerator facility ReA. This EBIT charge breeder is equipped with a unique superconducting magnet configuration, a combination of a solenoid and a pair of Helmholtz coils, allowing for a direct observation of the ion cloud while maintaining the advantages of a long ion trapping region. The current density of its electron beam is a key factor for efficient capture and fast charge breeding of continuously injected, short-lived isotope beams. It depends on the radius of the magnetically compressed electron beam. This radius is measured by imaging the highly charged ion cloud trapped within the electron beam with a pinhole camera, which is sensitive to X-rays emitted by the ions with photon energies between 2 keV and 10 keV. The 80%-radius of a cylindrical 800 mA electron beam with an energy of 15 keV is determined to be r{sub 80%}=(212±19)μm in a 4 T magnetic field. From this, a current density of j = (454 ± 83)A/cm{sup 2} is derived. These results are in good agreement with electron beam trajectory simulations performed with TriComp and serve as a test for future electron gun design developments.

  5. Measurement of inclusive charged current interactions on carbon in a few-GeV neutrino beam

    SciTech Connect

    Nakajima, Y.; Kubo, H.; Matsuoka, K.; Nakaya, T.; Orme, D.; Otani, M.; Yokoyama, M.; Alcaraz-Aunion, J. L.; Jover-Manas, G.; Sanchez, F.; Brice, S. J.; Finley, D. A.; Kobilarcik, T.; Moore, C. D.; Russell, A. D.; Stefanski, R. J.; Tesarek, R. J.; White, H. B.; Zeller, G. P.; Bugel, L.

    2011-01-01

    We report a measurement of inclusive charged current interactions of muon neutrinos on carbon with an average energy of 0.8 GeV using the Fermilab Booster Neutrino Beam. We compare our measurement with two neutrino interaction simulations: NEUT and NUANCE. The charged current interaction rates (product of flux and cross section) are extracted by fitting the muon kinematics, with a precision of 6%-15% for the energy dependent and 3% for the energy integrated analyses. We also extract charged current inclusive interaction cross sections from the observed rates, with a precision of 10%-30% for the energy dependent and 8% for the energy integrated analyses. This is the first measurement of the charged current inclusive cross section on carbon around 1 GeV. These results can be used to convert previous SciBooNE cross-section ratio measurements to absolute cross-section values.

  6. Suppression of the 1 MHz beam current modulation in the LEDA/CRITS proton source

    SciTech Connect

    Balleyguier, P.; Sherman, J.; Zaugg, T.

    1998-12-01

    Earlier operation of a microwave proton source exhibited an approximate 1-MHz modulation in the beam current. This oscillation could cause instabilities at higher energies in the linac, as the low-level RF control for linac operation rolls off at 200 kHz. Tests on a dummy load show the modulation is created by the magnetron itself: at a typical power level required for the source operation (680W), the 1-MHz sideband level was as high as {minus}4 dB from carrier. Since the magnetron exhibited better behavior at higher levels, a RF power attenuator is inserted to force the magnetron to run at a 50% higher power level for the same final power in the load. This attenuator is made of two antennas plunged in the waveguide and connected to dummy loads by a coaxial line. As the antenna are separated by a quarter of the guided wavelength, mismatching effects approximately cancel each other. The antenna length is experimentally adjusted to obtain the {minus}1.8 dB attenuation required. Magnetron operation at the higher power level gives a beam current spectrum free of the 1-MHz modulation, showing the coherent beam noise is not generated by plasma chamber phenomena.

  7. Development of a universal serial bus interface circuit for ion beam current integrators.

    PubMed

    Suresh, K; Panigrahi, B K; Nair, K G M

    2007-08-01

    A universal serial bus (USB) interface circuit has been developed to enable easy interfacing of commercial as well as custom-built ion beam current integrators to personal computer (PC) based automated experimental setups. Built using the popular PIC16F877A reduced instruction set computer and a USB-universal asynchronous receiver-transmitter/first in, first out controller, DLP2232, this USB interface circuit virtually emulates the ion beam current integrators on a host PC and uses USB 2.0 protocol to implement high speed bidirectional data transfer. Using this interface, many tedious and labor intensive ion beam irradiation and characterization experiments can be redesigned into PC based automated ones with advantages of improved accuracy, rapidity, and ease of use and control. This interface circuit was successfully used in carrying out online in situ resistivity measurement of 70 keV O(+) ion irradiated tin thin films using four probe method. In situ electrical resistance measurement showed the formation of SnO(2) phase during ion implantation.

  8. Suppression of a 1 MHz Beam Current Modulation in a Microwave Proton Source

    NASA Astrophysics Data System (ADS)

    Balleyguier, Pascal; Sherman, Joseph; Zaugg, Thomas

    1998-04-01

    Earlier operation of a microwave proton source exhibited an approximate 1-MHz modulation in the beam current. This oscillation could cause instabilities at higher energies in the linac, as the low-level RF control for linac operation rolls off at 200 kHz. Tests on a dummy load show the modulation is created by the magnetron itself: at a typical power level required for the source operation (680W), the 1-MHz sideband level was as high as -4 dB from carrier. Since the magnetron exhibited better behavior at higher levels, a RF power attenuator is inserted to force the magnetron to run at a 50 per cent higher power level for the same final power in the load. This attenuator is made of two antennas plunged in the waveguide and connected to dummy loads by a coaxial line. As the antenna are separated by a quarter of the guided wavelength, mismatching effects approximately cancel each other. The antenna length is experimentally adjusted to obtain the -1.8 dB attenuation required. Magnetron operation at the higher power level gives a beam current spectrum free of the 1-MHz modulation, showing the coherent beam noise is not generated by plasma chamber phenomena.

  9. Dark Currents and Their Effect on the Primary Beam in an X-band Linac

    SciTech Connect

    Bane, K.L.F.; Dolgashev, V.A.; Raubenheimer, T.; Stupakov, G.V.; Wu, J.H.; /SLAC

    2005-05-27

    We numerically study properties of primary dark currents in an X-band accelerating structure. For the H60VG3 structure considered for the Next Linear Collider (NLC) we first perform a fairly complete (with some approximations) calculation of dark current trajectories. These results are used to study properties of the dark current leaving the structure. For example, at accelerating gradient of 65 MV/m, considering two very different assumptions about dark current emission around the irises, we find that the fraction of emitted current leaving the structure to be a consistent {approx} 1%. Considering that {approx} 1 mA outgoing dark current is seen in measurement, this implies that {approx} 100 mA (or 10 pC per period) is emitted within the structure itself. Using the formalism of the Lienard-Wiechert potentials, we then perform a systematic calculation of the transverse kick of dark currents on a primary linac bunch. The result is {approx} 1 V kick per mA (or per 0.1 pC per period) dark current emitted from an iris. For an entire structure we estimate the total kick on a primary bunch to be {approx} 15 V. For the NLC linac this translates to a ratio of (final) vertical beam offset to beam size of about 0.2. However, with the assumptions that needed to be made--particularly the number of emitters and their distribution within a structure--the accuracy of this result may be limited to the order of magnitude.

  10. Dose rate dependence of the PTW 60019 microDiamond detector in high dose-per-pulse pulsed beams

    NASA Astrophysics Data System (ADS)

    Brualla-González, Luis; Gómez, Faustino; Pombar, Miguel; Pardo-Montero, Juan

    2016-01-01

    Recombination effects can affect the detectors used for the dosimetry of radiotherapy fields. They are important when using ionization chambers, especially in liquid-filled ionization chambers, and should be corrected for. The introduction of flattening-filter-free accelerators increases the typical dose-per-pulse used in radiotherapy beams, which leads to more important recombination effects. Diamond detectors provide a good solution for the dosimetry and quality assurance of small radiotherapy fields, due to their low energy dependence and small volume. The group of Università di Roma Tor Vergata has developed a synthetic diamond detector, which is commercialized by PTW as microDiamond detector type 60019. In this work we present an experimental characterization of the collection efficiency of the microDiamond detector, focusing on high dose-per-pulse FFF beams. The collection efficiency decreases with dose-per-pulse, down to 0.978 at 2.2 mGy/pulse, following a Fowler-Attix-like curve. On the other hand, we have found no significant dependence of the collection efficiency on the pulse repetition frequency (or pulse period).

  11. A comparative study of new and current methods for dental micro-CT image denoising

    PubMed Central

    Lashgari, Mojtaba; Qin, Jie; Swain, Michael

    2016-01-01

    Objectives: The aim of the current study was to evaluate the application of two advanced noise-reduction algorithms for dental micro-CT images and to implement a comparative analysis of the performance of new and current denoising algorithms. Methods: Denoising was performed using gaussian and median filters as the current filtering approaches and the block-matching and three-dimensional (BM3D) method and total variation method as the proposed new filtering techniques. The performance of the denoising methods was evaluated quantitatively using contrast-to-noise ratio (CNR), edge preserving index (EPI) and blurring indexes, as well as qualitatively using the double-stimulus continuous quality scale procedure. Results: The BM3D method had the best performance with regard to preservation of fine textural features (CNREdge), non-blurring of the whole image (blurring index), the clinical visual score in images with very fine features and the overall visual score for all types of images. On the other hand, the total variation method provided the best results with regard to smoothing of images in texture-free areas (CNRTex-free) and in preserving the edges and borders of image features (EPI). Conclusions: The BM3D method is the most reliable technique for denoising dental micro-CT images with very fine textural details, such as shallow enamel lesions, in which the preservation of the texture and fine features is of the greatest importance. On the other hand, the total variation method is the technique of choice for denoising images without very fine textural details in which the clinician or researcher is interested mainly in anatomical features and structural measurements. PMID:26764583

  12. SU-E-T-232: Micro Diamonds - Determination of Their Lateral Response Function Via Gap-Beam Dose Profiles

    SciTech Connect

    Poppinga, D; Looe, H; Chofor, N; Schoenfeld, A; Fischer, J; Meyners, J; Delfs, B; Stelljes, T; Poppe, B; Verona, C; Verona-Rinati, G; Marinelli, M; Harder, D

    2014-06-01

    Purpose: The aim of this study is the measurement of the lateral response function of microDiamonds by comparison with radiochromic film dose measurement. In this study a TM60019 microDiamond (PTW Freiburg, Germany) and a prototype synthetic diamond detector with smaller sensitive volume were investigated. Methods: Two lead blocks were positioned below the gantry head of an Elekta Synergy accelerator using a gantry mount. Between the blocks two sheets of paper were fixed. The water phantom was positioned below the gantry mount, so that the block to water distance was 20 cm. The gap beam profile was measured at 5 cm water depth by radiochromic EBT3 film and diamond detectors. The film was fixed on a RW3 plate, moved by the step motor system of the phantom and digitized by an Epson 10000XL scanner using the red color channel. Results: The lateral response of the prototype diamond detector is comparable to that of film measurements, i.e. has negligible width. This corresponds to the small detector volume of the prototype detector. In contrast to this the FWHM values of the gap-beam dose profiles measured with the TM60019 detector are somewhat larger, which corresponds to the larger sensitive detector volume. Conclusion: This study has illustrated the high spatial resolution of the diamond detectors. In comparison with filmmeasured narrow-beam dose profiles, the TM60019 has a spatial resolution function of about 2 mm FWHM, whereas the FWHM for the prototype is practically negligible. However due to the low signal caused by the small sensitive volume, measurements with the prototype in clinical routine are a challenge. On the other hand the TM60019 is a good compromise between detector volume and signal output and thus a well suited detector for most clinically relevant small field situations.

  13. Enhancing ablation efficiency in micro structuring using a deformable mirror for beam shaping of ultra-short laser pulses

    NASA Astrophysics Data System (ADS)

    Smarra, M.; Dickmann, K.

    2016-03-01

    Using ultra-short laser pulses for the generation of microstructures results in a high flexible tool for free form geometries in the micro range. Increasing laser power and repetition rates increase as well the demand of high flexible and efficient process strategies. To increase the ablation efficiency the optimal fluency can be determined, which is a material specific value. By varying the beam shape, the ablation efficiency can be enhanced. In this study a deformable mirror was used to vary the beam shape. This mirror is built by combining a piezo-electric ceramic and a mirror substrate. The ceramic is divided into several segments, which can be controlled independently. This results in a high flexible deformable mirror which influences the beam shape and can be used to vary the spot size or generate line geometries. The ablation efficiency and roughness of small generated cavities were analyzed in this study as well as the dimensions of the cavity. This can be used to optimize process strategies to combine high volume ablation and fine detail generation.

  14. Electron beam induced current profiling of the p-ZnO:N/n-GaN heterojunction

    SciTech Connect

    Przeździecka, E. Stachowicz, M.; Chusnutdinow, S.; Jakieła, R.; Kozanecki, A.

    2015-02-09

    The high quality p-n structures studied consist of nitrogen doped ZnO:N films grown by plasma assisted molecular beam epitaxy on n-type GaN templates. The nitrogen concentration, determined by secondary ion mass spectroscopy, is about 1 × 10{sup 20} cm{sup −3}. Temperature dependent photoluminescence studies confirm the presence of acceptor centers with an energy level lying approximately 130 meV above the valence band. The maximum forward-to-reverse current ratio I{sub F}/I{sub R} in the obtained p-n diodes is about 10{sup 7} at ±5 V, which is 2–5 orders of magnitude higher than previously reported for this type of heterojunctions. Electron-beam-induced current measurements confirm the presence of a p–n junction, located at the p-ZnO/n-GaN interface. The calculated diffusion length and activation energy of minority carriers are presented. The heterostructures exhibit strong absorption in the UV range with a four orders of magnitude high bright-to-dark current ratio.

  15. Proton beam writing of long, arbitrary structures for micro/nano photonics and fluidics applications

    NASA Astrophysics Data System (ADS)

    Udalagama, Chammika; Teo, E. J.; Chan, S. F.; Kumar, V. S.; Bettiol, A. A.; Watt, F.

    2011-10-01

    The last decade has seen proton beam writing maturing into a versatile lithographic technique able to produce sub-100 nm, high aspect ratio structures with smooth side walls. However, many applications in the fields of photonics and fluidics require the fabrication of structures with high spatial resolution that extends over several centimetres. This cannot be achieved by purely magnetic or electrostatic beam scanning due to the large off-axis beam aberrations in high demagnification systems. As a result, this has limited us to producing long straight structures using a combination of beam and stage scanning. In this work we have: (1) developed an algorithm to include any arbitrary pattern into the writing process by using a more versatile combination of beam and stage scanning while (2) incorporating the use of the ubiquitous AutoCAD DXF (drawing exchange format) into the design process. We demonstrate the capability of this approach in fabricating structures such as Y-splitters, Mach-Zehnder modulators and microfluidic channels that are over several centimetres in length, in polymer. We also present optimisation of such parameters as scanning speed and scanning loops to improve on the surface roughness of the structures. This work opens up new possibilities of using CAD software in PBW for microphotonics and fluidics device fabrication.

  16. Reduction of Beam Current Noise in the FNAL Magnetron Ion Source

    SciTech Connect

    Bollinger, D. S.; Karns, P. R.; Tan, C. Y.

    2014-01-01

    The new FNAL Injector Line with a circular dimple magnetron ion source has been operational since December of 2013. Since the new injector came on line there have been variations in the H- beam current flattop observed near the downstream end of the linac. Several different cathode geometries including a hollow cathode suggested by Dudnikov [1] were tried. We expanded on those studies by trying mixtures ranging from 0.25%N, 99.75%H to 3%N, 97%H. The results of these studies in our test stand will be presented in this paper.

  17. Impurity mapping in sulphide minerals using Time-resolved Ion Beam Induced Current imaging

    NASA Astrophysics Data System (ADS)

    Laird, Jamie S.; Johnson, Brett C.; Ganesan, Kumaravelu; Kandasamy, Sasikaran; Davidson, Garry; Borg, Stacey; Ryan, Chris G.

    2010-06-01

    The semiconducting properties and charge transport within natural minerals like pyrite are postulated to drive certain geochemical processes which can lead to precious metal ore genesis. In this paper we outline electrical measurements on mineral samples and present spatio-temporally resolved Ion Beam Induced Charge or Current studies on a Schottky pyrite junction. Au-Schottky contacts were fabricated in regions selected by thermoelectric and 4-point probe resistivity measurements. The complexity in charge transport due to impurity variations results in imaging contrast which is deemed important for fluid electrochemistry. The relevance of understanding charge collection in pyrite in the context of complex geochemical processes is briefly discussed.

  18. Low-threshold exocytosis induced by cAMP-recruited CaV3.2 (alpha1H) channels in rat chromaffin cells.

    PubMed

    Giancippoli, A; Novara, M; de Luca, A; Baldelli, P; Marcantoni, A; Carbone, E; Carabelli, V

    2006-03-01

    We have studied the functional role of CaV3 channels in triggering fast exocytosis in rat chromaffin cells (RCCs). CaV3 T-type channels were selectively recruited by chronic exposures to cAMP (3 days) via an exchange protein directly activated by cAMP (Epac)-mediated pathway. Here we show that cAMP-treated cells had increased secretory responses, which could be evoked even at very low depolarizations (-50, -40 mV). Potentiation of exocytosis in cAMP-treated cells did not occur in the presence of 50 microM Ni2+, which selectively blocks T-type currents in RCCs. This suggests that the "low-threshold exocytosis" induced by cAMP is due to increased Ca2+ influx through cAMP-recruited T-type channels, rather than to an enhanced secretion downstream of Ca2+ entry, as previously reported for short-term cAMP treatments (20 min). Newly recruited T-type channels increase the fast secretory response at low voltages without altering the size of the immediately releasable pool. They also preserve the Ca2+ dependence of exocytosis, the initial speed of vesicle depletion, and the mean quantal size of single secretory events. All this indicates that cAMP-recruited CaV3 channels enhance the secretory activity of RCCs at low voltages by coupling to the secretory apparatus with a Ca2+ efficacy similar to that of already existing high-threshold Ca2+ channels. Finally, using RT-PCRs we found that the fast inactivating low-threshold Ca2+ current component recruited by cAMP is selectively associated to the alpha1H (CaV3.2) channel isoform.

  19. SU-E-T-08: A Beam Source Model for Monte Carlo Simulations of a Double-Scattering Proton Beam Delivery System Using Beam Current Modulation

    SciTech Connect

    Shin, J; Merchant, T E; Lee, S; Li, Z; Shin, D; Farr, J B

    2015-06-15

    Purpose: To reconstruct phase-space information upstream of patient specific collimators for Monte Carlo simulations using only radiotherapy planning system data. Methods: The proton energies are calculated based on residual ranges, e.g., sum of prescribed ranges in a patient and SSD. The Kapchinskij and Vladimirskij (KV) distribution was applied to sample proton’s x-y positions and momentum direction and the beam shape was assumed to be a circle. Free parameters, e.g., the initial energy spread and the emittance of KV distribution were estimated from the benchmarking with commissioning data in a commercial treatment planning system for an operational proton therapy center. The number of histories, which defines the height of individual pristine Bragg peaks (BP) of Spread-out Bragg peak (SOBP), are weighted based on beam current modulation and a correction factor is applied to take into account the fluence reduction as the residual range decreases due to the rotation of the range modulator wheel. The timedependent behaviors, e.g., the changes of the residual range and histories per a pristine BP, are realized by utilizing TOPAS (Tool for Particle Simulation). Results: Benchmarking simulations for selected SOBPs ranging 7.5 cm to 15.5 cm matched within 2 mm in range and up to 5 mm in SOBP width against measurement data in water phantom. We found this model tends to underestimate entrance dose by about 5 % in comparison to measurement. This was attributed to the situation that the energy distribution used in the model was limited in its granularity at the limit of single energy spectrum for the narrow angle modulator steps used in the proximal pull back region of the SOBPs. Conclusion: Within these limitations the source modeling method proved itself an acceptable alternative of a full treatment head simulation when the machine geometry and materials information are not available.

  20. High-resolution velocimetry in energetic tidal currents using a convergent-beam acoustic Doppler profiler

    SciTech Connect

    Sellar, Brian; Harding, Samuel F.; Richmond, Marshall C.

    2015-07-16

    An array of convergent acoustic Doppler velocimeters has been developed and tested for the high resolution measurement of three-dimensional tidal flow velocities in an energetic tidal site. This configuration has been developed to increase spatial resolution of velocity measurements in comparison to conventional acoustic Doppler profilers (ADPs) which characteristically use diverging acoustic beams emanating from a single instrument. This is achieved using converging acoustic beams with a sample volume at the focal point of 0.03 m3. The array is also able to simultaneously measure three-dimensional velocity components in a profile throughout the water column, and as such is referred to herein as a converging-beam acoustic Doppler profiler (CADP). Mid-depth profiling is achieved through integration of the sensor platform with the operational Alstom 1MW DeepGen-IV Tidal Turbine. This proof-of-concept paper outlines system configuration and comparison to measurements provided by co-installed reference instrumentation. Comparison of CADP to standard ADP velocity measurements reveals a mean difference of 8 mm/s, standard deviation of 18 mm/s, and order-of-magnitude reduction in realizable length-scale. CADP focal point measurements compared to a proximal single-beam reference show peak cross-correlation coefficient of 0.96 over 4.0 s averaging period and a 47% reduction in Doppler noise. The dual functionality of the CADP as a profiling instrument with a high resolution focal point make this configuration a unique and valuable advancement in underwater velocimetry enabling improved turbulence, resource and structural loading quantification and validation of numerical simulations. Alternative modes of operation have been implemented including noise-reducing bi-static sampling. Since waves are simultaneously measured it is expected that derivatives of this system will be a powerful tool in wave-current interaction studies.

  1. High current density ion beam obtained by a transition to a highly focused state in extremely low-energy region

    SciTech Connect

    Hirano, Y. E-mail: hirano.yoichi@phys.cst.nihon-u.ac.jp; Kiyama, S.; Koguchi, H.; Fujiwara, Y.; Sakakita, H.

    2015-11-15

    A high current density (≈3 mA/cm{sup 2}) hydrogen ion beam source operating in an extremely low-energy region (E{sub ib} ≈ 150–200 eV) has been realized by using a transition to a highly focused state, where the beam is extracted from the ion source chamber through three concave electrodes with nominal focal lengths of ≈350 mm. The transition occurs when the beam energy exceeds a threshold value between 145 and 170 eV. Low-level hysteresis is observed in the transition when E{sub ib} is being reduced. The radial profiles of the ion beam current density and the low temperature ion current density can be obtained separately using a Faraday cup with a grid in front. The measured profiles confirm that more than a half of the extracted beam ions reaches the target plate with a good focusing profile with a full width at half maximum of ≈3 cm. Estimation of the particle balances in beam ions, the slow ions, and the electrons indicates the possibility that the secondary electron emission from the target plate and electron impact ionization of hydrogen may play roles as particle sources in this extremely low-energy beam after the compensation of beam ion space charge.

  2. High current density ion beam obtained by a transition to a highly focused state in extremely low-energy region.

    PubMed

    Hirano, Y; Kiyama, S; Fujiwara, Y; Koguchi, H; Sakakita, H

    2015-11-01

    A high current density (≈3 mA/cm(2)) hydrogen ion beam source operating in an extremely low-energy region (E(ib) ≈ 150-200 eV) has been realized by using a transition to a highly focused state, where the beam is extracted from the ion source chamber through three concave electrodes with nominal focal lengths of ≈350 mm. The transition occurs when the beam energy exceeds a threshold value between 145 and 170 eV. Low-level hysteresis is observed in the transition when E(ib) is being reduced. The radial profiles of the ion beam current density and the low temperature ion current density can be obtained separately using a Faraday cup with a grid in front. The measured profiles confirm that more than a half of the extracted beam ions reaches the target plate with a good focusing profile with a full width at half maximum of ≈3 cm. Estimation of the particle balances in beam ions, the slow ions, and the electrons indicates the possibility that the secondary electron emission from the target plate and electron impact ionization of hydrogen may play roles as particle sources in this extremely low-energy beam after the compensation of beam ion space charge.

  3. Sensitivities in the production of spread-out Bragg peak dose distributions by passive scattering with beam current modulation

    SciTech Connect

    Lu, H.-M.; Brett, Robert; Engelsman, Martijn; Slopsema, Roelf; Kooy, Hanne; Flanz, Jay

    2007-10-15

    A spread-out Bragg peak (SOBP) is used in proton beam therapy to create a longitudinal conformality of the required dose to the target. In order to create this effect in a passive beam scattering system, a variety of components must operate in conjunction to produce the desired beam parameters. We will describe how the SOBP is generated and will explore the tolerances of the various components and their subsequent effect on the dose distribution. A specific aspect of this investigation includes a case study involving the use of a beam current modulated system. In such a system, the intensity of the beam current can be varied in synchronization with the revolution of the range-modulator wheel. As a result, the weights of the pulled-back Bragg peaks can be individually controlled to produce uniform dose plateaus for a large range of treatment depths using only a small number of modulator wheels.

  4. AMPED Program Overview

    ScienceCinema

    Gur, Ilan

    2016-07-12

    An overview presentation about ARPA-E's AMPED program. AMPED projects seek to develop advanced sensing, control, and power management technologies that redefine the way we think about battery management. Energy storage can significantly improve U.S. energy independence, efficiency, and security by enabling a new generation of electric vehicles. While rapid progress is being made in new battery materials and storage technologies, few innovations have emerged in the management of advanced battery systems. AMPED aims to unlock enormous untapped potential in the performance, safety, and lifetime of today's commercial battery systems exclusively through system-level innovations, and is thus distinct from existing efforts to enhance underlying battery materials and architectures.

  5. AMPED Program Overview

    SciTech Connect

    Gur, Ilan

    2014-03-04

    An overview presentation about ARPA-E's AMPED program. AMPED projects seek to develop advanced sensing, control, and power management technologies that redefine the way we think about battery management. Energy storage can significantly improve U.S. energy independence, efficiency, and security by enabling a new generation of electric vehicles. While rapid progress is being made in new battery materials and storage technologies, few innovations have emerged in the management of advanced battery systems. AMPED aims to unlock enormous untapped potential in the performance, safety, and lifetime of today's commercial battery systems exclusively through system-level innovations, and is thus distinct from existing efforts to enhance underlying battery materials and architectures.

  6. Displacement sensing based on resonant frequency monitoring of electrostatically actuated curved micro beams

    NASA Astrophysics Data System (ADS)

    Krakover, Naftaly; Ilic, B. Robert; Krylov, Slava

    2016-11-01

    The ability to control nonlinear interactions of suspended mechanical structures offers a unique opportunity to engineer rich dynamical behavior that extends the dynamic range and ultimate device sensitivity. We demonstrate a displacement sensing technique based on resonant frequency monitoring of curved, doubly clamped, bistable micromechanical beams interacting with a movable electrode. In this configuration, the electrode displacement influences the nonlinear electrostatic interactions, effective stiffness and frequency of the curved beam. Increased sensitivity is made possible by dynamically operating the beam near the snap-through bistability onset. Various in-plane device architectures were fabricated from single crystal silicon and measured under ambient conditions using laser Doppler vibrometry. In agreement with the reduced order Galerkin-based model predictions, our experimental results show a significant resonant frequency reduction near critical snap-through, followed by a frequency increase within the post-buckling configuration. Interactions with a stationary electrode yield a voltage sensitivity up to  ≈560 Hz V-1 and results with a movable electrode allow motion sensitivity up to  ≈1.5 Hz nm-1. Our theoretical and experimental results collectively reveal the potential of displacement sensing using nonlinear interactions of geometrically curved beams near instabilities, with possible applications ranging from highly sensitive resonant inertial detectors to complex optomechanical platforms providing an interface between the classical and quantum domains.

  7. New methods for high current fast ion beam production by laser-driven acceleration.

    PubMed

    Margarone, D; Krasa, J; Prokupek, J; Velyhan, A; Torrisi, L; Picciotto, A; Giuffrida, L; Gammino, S; Cirrone, P; Cutroneo, M; Romano, F; Serra, E; Mangione, A; Rosinski, M; Parys, P; Ryc, L; Limpouch, J; Laska, L; Jungwirth, K; Ullschmied, J; Mocek, T; Korn, G; Rus, B

    2012-02-01

    An overview of the last experimental campaigns on laser-driven ion acceleration performed at the PALS facility in Prague is given. Both the 2 TW, sub-nanosecond iodine laser system and the 20 TW, femtosecond Ti:sapphire laser, recently installed at PALS, are used along our experiments performed in the intensity range 10(16)-10(19) W∕cm(2). The main goal of our studies was to generate high energy, high current ion streams at relatively low laser intensities. The discussed experimental investigations show promising results in terms of maximum ion energy and current density, which make the laser-accelerated ion beams a candidate for new-generation ion sources to be employed in medicine, nuclear physics, matter physics, and industry.

  8. Measurement of inclusive charged current interactions on carbon in a few-GeV neutrino beam

    SciTech Connect

    Nakajima, Y.; jima, Y.Naka; Alcaraz-Aunion, J.L.; Brice, S.J.; Bugel, L.; Catala-Perez, J.; Cheng, G.; Conrad, J.M.; Djurcic, Z.; Dore, U.; Finley, D.A.; /Kyoto U. /Barcelona, IFAE /Fermilab /MIT /Valencia U. /Columbia U. /MIT /Columbia U. /INFN, Rome /Rome U. /Fermilab /Columbia U. /INFN, Rome /Rome U.

    2010-11-01

    The SciBooNE Collaboration reports a measurement of inclusive charged current interactions of muon neutrinos on carbon with an average energy of 0.8 GeV using the Fermilab Booster Neutrino Beam. We compare our measurement with two neutrino interaction simulations: NEUT and NUANCE. The charged current interaction rates (product of flux and cross section) are extracted by fitting the muon kinematics, with a precision of 6-15% for the energy dependent and 3% for the energy integrated analyses. We also extract CC inclusive interaction cross sections from the observed rates, with a precision of 10-30% for the energy dependent and 8% for the energy integrated analyses. This is the first measurement of the CC inclusive cross section on carbon around 1 GeV. These results can be used to convert previous SciBooNE cross section ratio measurements to absolute cross section values.

  9. Investigation of degradation mechanisms of perovskite-based photovoltaic devices using laser beam induced current mapping

    NASA Astrophysics Data System (ADS)

    Song, Zhaoning; Watthage, Suneth C.; Phillips, Adam B.; Liyanage, Geethika K.; Khanal, Rajendra R.; Tompkins, Brandon L.; Ellingson, Randy J.; Heben, Michael J.

    2015-09-01

    Solution processed thin film photovoltaic devices incorporating organohalide perovskites have progressed rapidly in recent years and achieved energy conversion efficiencies greater than 20%. However, an important issue limiting their commercialization is that device efficiencies often drop within the first few hundred hours of operation. To explore the origin of the device degradation and failure in perovskite solar cells, we investigated the spatial uniformity of current collection at different stages of aging using two-dimensional laser beam induced current (LBIC) mapping. We validated that the local decomposition of the perovskite material is likely due to interactions with moisture in the air by comparing photocurrent collection in perovskite devices that were maintained in different controlled environments. We show that the addition of a poly(methyl methacrylate)/single-wall carbon nanotube (PMMA/SWCNT) encapsulation layer prevents degradation of the device in moist air. This suggests a route toward perovskite solar cells with improved operational stability and moisture resistance.

  10. Current-induced spin polarization on metal surfaces probed by spin-polarized positron beam.

    PubMed

    Zhang, H J; Yamamoto, S; Fukaya, Y; Maekawa, M; Li, H; Kawasuso, A; Seki, T; Saitoh, E; Takanashi, K

    2014-04-29

    Current-induced spin polarization (CISP) on the outermost surfaces of Au, Cu, Pt, Pd, Ta, and W nanoscaled films were studied using a spin-polarized positron beam. The Au and Cu surfaces showed no significant CISP. In contrast, the Pt, Pd, Ta, and W films exhibited large CISP (3~15% per input charge current of 10(5) A/cm(2)) and the CISP of Ta and W were opposite to those of Pt and Pd. The sign of the CISP obeys the same rule in spin Hall effect suggesting that the spin-orbit coupling is mainly responsible for the CISP. The magnitude of the CISP is explained by the Rashba-Edelstein mechanism rather than the diffusive spin Hall effect. This settles a controversy, that which of these two mechanisms dominates the large CISP on metal surfaces.

  11. Calibration of eddy current carburization measurements in ethylene production tubes using ion beam analysis

    NASA Astrophysics Data System (ADS)

    Stevens, K. J.; Trompetter, W. J.

    2004-02-01

    Nuclear reaction analysis using a 12C(d, p0)13C reaction and a 16O(d, p1)17O reaction, with 1.02 MeV deuterons in an accelerator microprobe, has been used to produce quantitative linescans of the carbon and oxygen levels in ex-service ethylene pyrolysis tubes of HPM, HK40 and Manaurite XM alloy. Particle induced x-ray emission in the ion beam microprobe and energy dispersive analysis of x-rays in a scanning electron microscope were used for linescans of the heavier elements (Cr, Ni, Fe, Si and Ti). The composition linescans were used to calibrate the response and accuracy of an eddy current probe system for measuring carburization near the inner surface of the tubes. The influence of the ferromagnetic outer oxide surface layers has been clarified. A two-dimensional ANSYS finite element model (FEM) was used for interpretation of the eddy current scans. Good correlation was obtained between the ion beam analysis results, the impedance scans and the FEM.

  12. Progress and future developments of high current ion source for neutral beam injector in the ASIPP

    NASA Astrophysics Data System (ADS)

    Hu, Chundong; Xie, Yahong; Xie, Yuanlai; Liu, Sheng; Liu, Zhimin; Xu, Yongjian; Liang, Lizhen; Sheng, Peng; Jiang, Caichao

    2015-04-01

    A high current hot cathode bucket ion source, which based on the US long pulse ion source is developed in Institute of Plasma Physics, Chinese Academy of Sciences. The ion source consists of a bucket plasma generator with multi-pole cusp fields and a set of tetrode accelerator with slit apertures. So far, four ion sources are developed and conditioned on the ion source test bed. 4 MW hydrogen beam with beam energy of 80 keV is extracted. In Aug. 2013, EAST NBI 1 with two ion source installed on the EAST, and achieved H-mode plasma with NBI injection for the first time. In order to achieve stable long pulse operation of high current ion source and negative ion source research, the RF ion source with 200 mm diameter and 120 mm depth driver is designed and developed. The first RF plasma generated with 2 kW power of 1 MHz frequency. More of the RF plasma tests and negative source relative research need to do in the future.

  13. Progress and future developments of high current ion source for neutral beam injector in the ASIPP

    SciTech Connect

    Hu, Chundong; Xie, Yahong Xie, Yuanlai; Liu, Sheng; Liu, Zhimin; Xu, Yongjian; Liang, Lizhen; Sheng, Peng; Jiang, Caichao

    2015-04-08

    A high current hot cathode bucket ion source, which based on the US long pulse ion source is developed in Institute of Plasma Physics, Chinese Academy of Sciences. The ion source consists of a bucket plasma generator with multi-pole cusp fields and a set of tetrode accelerator with slit apertures. So far, four ion sources are developed and conditioned on the ion source test bed. 4 MW hydrogen beam with beam energy of 80 keV is extracted. In Aug. 2013, EAST NBI 1 with two ion source installed on the EAST, and achieved H-mode plasma with NBI injection for the first time. In order to achieve stable long pulse operation of high current ion source and negative ion source research, the RF ion source with 200 mm diameter and 120 mm depth driver is designed and developed. The first RF plasma generated with 2 kW power of 1 MHz frequency. More of the RF plasma tests and negative source relative research need to do in the future.

  14. Up-regulation of low-threshold tetrodotoxin-resistant Na+ current via activation of a cyclic AMP/protein kinase A pathway in nociceptor-like rat dorsal root ganglion cells.

    PubMed

    Scroggs, R S

    2011-07-14

    The effects of forskolin on low-threshold tetrodotoxin-resistant (TTX-r) Na(+) currents was studied in small diameter (average ≈ 25 μm) dorsal root ganglion (DRG) cells. All DRG cells included in the study were categorized as type-2 or non-type-2 based on the expression of a low-threshold A-current. In all type-2 and some non-type-2 DRG cells held at -80 mV, the adenylyl cyclase (AC) activator forskolin (10 μM) up-regulated TTX-r Na(+) currents evoked with steps to -55 mV through -35 mV (low-threshold current). Up-regulation of low-threshold current by forskolin was mimicked by the protein kinase A (PKA) agonist Sp-cAMPs and the inflammatory mediator serotonin, and blocked by the PKA antagonist Rp-cAMPs. Forskolin-induced up-regulation of low-threshold current evoked from a holding potential of -60 mV was blocked by 40 ms steps to 0 mV, which presumably induced a long lasting inactivation of the low-threshold channels. Reducing to 3 ms the duration of steps to 0 mV, significantly increased the number of DRG cells where low-threshold current was up-regulated by forskolin, presumably by reducing the long-lasting inactivation of the low-threshold channels. In the same cells, high-threshold current, evoked by 40 ms or 3 ms steps to 0 mV, was consistently up-regulated by forskolin. The selective Na(V)1.8 channel blocker A-803467 markedly blocked high-threshold current but not low-threshold current. The different voltage protocols observed to activate and inactivate the low- and high-threshold currents, and the observation that A-803467 blocked high- but not low-threshold current suggests that the two currents were mediated by different channels, possibly Na(V)1.8 and Na(V)1.9, respectively. Inflammatory mediators may simultaneously up-regulate Na(V)1.8 and Na(V)1.9 channels in the same nociceptor via a AC/PKA signaling pathway, increasing nociceptor signaling strength, and lowering nociceptor threshold, respectively.

  15. Micro-nanopores fabricated by high-energy electron beam irradiation: suitable structure for controlling pesticide loss.

    PubMed

    Xiang, Yubin; Wang, Ning; Song, Jimei; Cai, Dongqing; Wu, Zhengyan

    2013-06-05

    Pesticide sprayed onto crop leaves tends to be washed off by rainwater and discharge into the environment through leaching and runoff, resulting in severe pollution to both soil and water. Here, to control pesticide loss, we developed a loss-control pesticide (LCP) by adding modified natural nanoclay (diatomite) through high-energy electron beam (HEEB) to traditional pesticide. After HEEB treatment, the originally clogged pores in diatomite opened, resulting in plenty of micro-nanopores in diatomite, which are beneficial for the pesticide molecules to access and be adsorbed. This pesticide-diatomite complex tended to be retained by the rough surface of crop leaves, displaying a high adhesion performance onto the leaves, so that the pesticide loss reduced, sufficient pesticide for crops was supplied, and the pollution risk of the pesticide could be substantially lowered.

  16. Structural transitions in electron beam deposited Co-carbonyl suspended nanowires at high electrical current densities.

    PubMed

    Gazzadi, Gian Carlo; Frabboni, Stefano

    2015-01-01

    Suspended nanowires (SNWs) have been deposited from Co-carbonyl precursor (Co2(CO)8) by focused electron beam induced deposition (FEBID). The SNWs dimensions are about 30-50 nm in diameter and 600-850 nm in length. The as-deposited material has a nanogranular structure of mixed face-centered cubic (FCC) and hexagonal close-packed (HCP) Co phases, and a composition of 80 atom % Co, 15 atom % O and 5 atom % C, as revealed by transmission electron microscopy (TEM) analysis and by energy-dispersive X-ray (EDX) spectroscopy, respectively. Current (I)-voltage (V) measurements with current densities up to 10(7) A/cm(2) determine different structural transitions in the SNWs, depending on the I-V history. A single measurement with a sudden current burst leads to a polycrystalline FCC Co structure extended over the whole wire. Repeated measurements at increasing currents produce wires with a split structure: one half is polycrystalline FCC Co and the other half is graphitized C. The breakdown current density is found at 2.1 × 10(7) A/cm(2). The role played by resistive heating and electromigration in these transitions is discussed.

  17. High-resolution velocimetry in energetic tidal currents using a convergent-beam acoustic Doppler profiler

    NASA Astrophysics Data System (ADS)

    Sellar, Brian; Harding, Samuel; Richmond, Marshall

    2015-08-01

    An array of single-beam acoustic Doppler profilers has been developed for the high resolution measurement of three-dimensional tidal flow velocities and subsequently tested in an energetic tidal site. This configuration has been developed to increase spatial resolution of velocity measurements in comparison to conventional acoustic Doppler profilers (ADPs) which characteristically use divergent acoustic beams emanating from a single instrument. This is achieved using geometrically convergent acoustic beams creating a sample volume at the focal point of 0.03 m3. Away from the focal point, the array is also able to simultaneously reconstruct three-dimensional velocity components in a profile throughout the water column, and is referred to herein as a convergent-beam acoustic Doppler profiler (C-ADP). Mid-depth profiling is achieved through integration of the sensor platform with the operational commercial-scale Alstom 1 MW DeepGen-IV Tidal Turbine deployed at the European Marine Energy Center, Orkney Isles, UK. This proof-of-concept paper outlines the C-ADP system configuration and comparison to measurements provided by co-installed reference instrumentation. Comparison of C-ADP to standard divergent ADP (D-ADP) velocity measurements reveals a mean difference of 8 mm s-1, standard deviation of 18 mm s-1, and an order of magnitude reduction in realisable length scale. C-ADP focal point measurements compared to a proximal single-beam reference show peak cross-correlation coefficient of 0.96 over 4.0 s averaging period and a 47% reduction in Doppler noise. The dual functionality of the C-ADP as a profiling instrument with a high resolution focal point make this configuration a unique and valuable advancement in underwater velocimetry enabling improved quantification of flow turbulence. Since waves are simultaneously measured via profiled velocities, pressure measurements and surface detection, it is expected that derivatives of this system will be a powerful tool in

  18. Raster-scanning serial protein crystallography using micro- and nano-focused synchrotron beams.

    PubMed

    Coquelle, Nicolas; Brewster, Aaron S; Kapp, Ulrike; Shilova, Anastasya; Weinhausen, Britta; Burghammer, Manfred; Colletier, Jacques Philippe

    2015-05-01

    High-resolution structural information was obtained from lysozyme microcrystals (20 µm in the largest dimension) using raster-scanning serial protein crystallography on micro- and nano-focused beamlines at the ESRF. Data were collected at room temperature (RT) from crystals sandwiched between two silicon nitride wafers, thereby preventing their drying, while limiting background scattering and sample consumption. In order to identify crystal hits, new multi-processing and GUI-driven Python-based pre-analysis software was developed, named NanoPeakCell, that was able to read data from a variety of crystallographic image formats. Further data processing was carried out using CrystFEL, and the resultant structures were refined to 1.7 Å resolution. The data demonstrate the feasibility of RT raster-scanning serial micro- and nano-protein crystallography at synchrotrons and validate it as an alternative approach for the collection of high-resolution structural data from micro-sized crystals. Advantages of the proposed approach are its thriftiness, its handling-free nature, the reduced amount of sample required, the adjustable hit rate, the high indexing rate and the minimization of background scattering.

  19. Raster-scanning serial protein crystallography using micro- and nano-focused synchrotron beams

    SciTech Connect

    Coquelle, Nicolas; Brewster, Aaron S.; Kapp, Ulrike; Shilova, Anastasya; Weinhausen, Britta; Burghammer, Manfred; Colletier, Jacques-Philippe

    2015-05-01

    A raster scanning serial protein crystallography approach is presented, that consumes as low ∼200–700 nl of sedimented crystals. New serial data pre-analysis software, NanoPeakCell, is introduced. High-resolution structural information was obtained from lysozyme microcrystals (20 µm in the largest dimension) using raster-scanning serial protein crystallography on micro- and nano-focused beamlines at the ESRF. Data were collected at room temperature (RT) from crystals sandwiched between two silicon nitride wafers, thereby preventing their drying, while limiting background scattering and sample consumption. In order to identify crystal hits, new multi-processing and GUI-driven Python-based pre-analysis software was developed, named NanoPeakCell, that was able to read data from a variety of crystallographic image formats. Further data processing was carried out using CrystFEL, and the resultant structures were refined to 1.7 Å resolution. The data demonstrate the feasibility of RT raster-scanning serial micro- and nano-protein crystallography at synchrotrons and validate it as an alternative approach for the collection of high-resolution structural data from micro-sized crystals. Advantages of the proposed approach are its thriftiness, its handling-free nature, the reduced amount of sample required, the adjustable hit rate, the high indexing rate and the minimization of background scattering.

  20. Raster-scanning serial protein crystallography using micro- and nano-focused synchrotron beams

    DOE PAGES

    Coquelle, Nicolas; Brewster, Aaron S.; Kapp, Ulrike; ...

    2015-04-25

    High-resolution structural information was obtained from lysozyme microcrystals (20 µm in the largest dimension) using raster-scanning serial protein crystallography on micro- and nano-focused beamlines at the ESRF. Data were collected at room temperature (RT) from crystals sandwiched between two silicon nitride wafers, thereby preventing their drying, while limiting background scattering and sample consumption. In order to identify crystal hits, new multi-processing and GUI-driven Python-based pre-analysis software was developed, named NanoPeakCell, that was able to read data from a variety of crystallographic image formats. Further data processing was carried out using CrystFEL, and the resultant structures were refined to 1.7 Åmore » resolution. The data demonstrate the feasibility of RT raster-scanning serial micro- and nano-protein crystallography at synchrotrons and validate it as an alternative approach for the collection of high-resolution structural data from micro-sized crystals. Advantages of the proposed approach are its thriftiness, its handling-free nature, the reduced amount of sample required, the adjustable hit rate, the high indexing rate and the minimization of background scattering.« less

  1. Raster-scanning serial protein crystallography using micro- and nano-focused synchrotron beams

    SciTech Connect

    Coquelle, Nicolas; Brewster, Aaron S.; Kapp, Ulrike; Shilova, Anastasya; Weinhausen, Britta; Burghammer, Manfred; Colletier, Jacques -Philippe

    2015-04-25

    High-resolution structural information was obtained from lysozyme microcrystals (20 µm in the largest dimension) using raster-scanning serial protein crystallography on micro- and nano-focused beamlines at the ESRF. Data were collected at room temperature (RT) from crystals sandwiched between two silicon nitride wafers, thereby preventing their drying, while limiting background scattering and sample consumption. In order to identify crystal hits, new multi-processing and GUI-driven Python-based pre-analysis software was developed, named NanoPeakCell, that was able to read data from a variety of crystallographic image formats. Further data processing was carried out using CrystFEL, and the resultant structures were refined to 1.7 Å resolution. The data demonstrate the feasibility of RT raster-scanning serial micro- and nano-protein crystallography at synchrotrons and validate it as an alternative approach for the collection of high-resolution structural data from micro-sized crystals. Advantages of the proposed approach are its thriftiness, its handling-free nature, the reduced amount of sample required, the adjustable hit rate, the high indexing rate and the minimization of background scattering.

  2. Raster-scanning serial protein crystallography using micro- and nano-focused synchrotron beams

    PubMed Central

    Coquelle, Nicolas; Brewster, Aaron S.; Kapp, Ulrike; Shilova, Anastasya; Weinhausen, Britta; Burghammer, Manfred; Colletier, Jacques-Philippe

    2015-01-01

    High-resolution structural information was obtained from lysozyme microcrystals (20 µm in the largest dimension) using raster-scanning serial protein crystallography on micro- and nano-focused beamlines at the ESRF. Data were collected at room temperature (RT) from crystals sandwiched between two silicon nitride wafers, thereby preventing their drying, while limiting background scattering and sample consumption. In order to identify crystal hits, new multi-processing and GUI-driven Python-based pre-analysis software was developed, named NanoPeakCell, that was able to read data from a variety of crystallographic image formats. Further data processing was carried out using CrystFEL, and the resultant structures were refined to 1.7 Å resolution. The data demonstrate the feasibility of RT raster-scanning serial micro- and nano-protein crystallography at synchrotrons and validate it as an alternative approach for the collection of high-resolution structural data from micro-sized crystals. Advantages of the proposed approach are its thriftiness, its handling-free nature, the reduced amount of sample required, the adjustable hit rate, the high indexing rate and the minimization of background scattering. PMID:25945583

  3. Cathode performance during two beam operation of the high current high polarization electron gun for eRHIC

    SciTech Connect

    Rahman, O.; Ben-Zvi, I.; Degen, C.; Gassner, D. M.; Lambiase, R.; Meng, W.; Pikin, A.; Rao, T.; Sheehy, B.; Skaritka, J.; Wang, E.; Pietz, J.; Ackeret, M.; Yeckel, C.; Miller, R.; Dobrin, E.; Thompson, K.

    2015-05-03

    Two electron beams from two activated bulk GaAs photocathodes were successfully combined during the recent beam test of the High Current High Polarization Electron gun for eRHIC. The beam test took place in Stangenes Industries in Palo Alto, CA, where the cathodes were placed in diagonally opposite locations inside the high voltage shroud. No significant cross talking between the cathodes was found for the pertinent vacuum and low average current operation, which is very promising towards combining multiple beams for higher average current. This paper describes the cathode preparation, transport and cathode performance in the gun for the combining test, including the QE and lifetimes of the photocathodes at various steps of the experiment.

  4. Two-stream stability properties of the return-current layer for intense ion beam propagation through background plasma

    SciTech Connect

    Startsev, Edward A.; Davidson, Ronald C.; Dorf, Mikhail

    2009-09-15

    When an ion beam with sharp edge propagates through a background plasma, its current is neutralized by the plasma return current everywhere except at the beam edge over a characteristic transverse distance {delta}x{sub perpendicular}{approx}{delta}{sub pe}, where {delta}{sub pe}=c/{omega}{sub pe} is the collisionless skin depth and {omega}{sub pe} is the electron plasma frequency. Because the background plasma electrons neutralizing the ion beam current inside the beam are streaming relative to the background plasma electrons outside the beam, the background plasma can support a two-stream surface-mode excitation. Such surface modes have been studied previously assuming complete charge and current neutralization, and have been shown to be strongly unstable. In this paper we study the detailed stability properties of this two-stream surface mode for an electron flow velocity profile self-consistently driven by the ion beam. In particular, it is shown that the self-magnetic field generated inside the unneutralized current layer, which has not been taken into account previously, completely eliminates the instability.

  5. High-intensity laser-accelerated ion beam produced from cryogenic micro-jet target.

    PubMed

    Gauthier, M; Kim, J B; Curry, C B; Aurand, B; Gamboa, E J; Göde, S; Goyon, C; Hazi, A; Kerr, S; Pak, A; Propp, A; Ramakrishna, B; Ruby, J; Willi, O; Williams, G J; Rödel, C; Glenzer, S H

    2016-11-01

    We report on the successful operation of a newly developed cryogenic jet target at high intensity laser-irradiation. Using the frequency-doubled Titan short pulse laser system at Jupiter Laser Facility, Lawrence Livermore National Laboratory, we demonstrate the generation of a pure proton beam a with maximum energy of 2 MeV. Furthermore, we record a quasi-monoenergetic peak at 1.1 MeV in the proton spectrum emitted in the laser forward direction suggesting an alternative acceleration mechanism. Using a solid-density mixed hydrogen-deuterium target, we are also able to produce pure proton-deuteron ion beams. With its high purity, limited size, near-critical density, and high-repetition rate capability, this target is promising for future applications.

  6. High-intensity laser-accelerated ion beam produced from cryogenic micro-jet target

    NASA Astrophysics Data System (ADS)

    Gauthier, M.; Kim, J. B.; Curry, C. B.; Aurand, B.; Gamboa, E. J.; Göde, S.; Goyon, C.; Hazi, A.; Kerr, S.; Pak, A.; Propp, A.; Ramakrishna, B.; Ruby, J.; Willi, O.; Williams, G. J.; Rödel, C.; Glenzer, S. H.

    2016-11-01

    We report on the successful operation of a newly developed cryogenic jet target at high intensity laser-irradiation. Using the frequency-doubled Titan short pulse laser system at Jupiter Laser Facility, Lawrence Livermore National Laboratory, we demonstrate the generation of a pure proton beam a with maximum energy of 2 MeV. Furthermore, we record a quasi-monoenergetic peak at 1.1 MeV in the proton spectrum emitted in the laser forward direction suggesting an alternative acceleration mechanism. Using a solid-density mixed hydrogen-deuterium target, we are also able to produce pure proton-deuteron ion beams. With its high purity, limited size, near-critical density, and high-repetition rate capability, this target is promising for future applications.

  7. High-intensity laser-accelerated ion beam produced from cryogenic micro-jet target

    DOE PAGES

    Gauthier, M.; Kim, J. B.; Curry, C. B.; ...

    2016-08-24

    Here, we report on the successful operation of a newly developed cryogenic jet target at high intensity laser-irradiation. Using the frequency-doubled Titan short pulse laser system at Jupiter Laser Facility, Lawrence Livermore National Laboratory, we demonstrate the generation of a pure proton beam a with maximum energy of 2 MeV. Furthermore, we record a quasi-monoenergetic peak at 1.1 MeV in the proton spectrum emitted in the laser forward direction suggesting an alternative acceleration mechanism. Using a solid-density mixed hydrogen-deuterium target, we are also able to produce pure proton-deuteron ion beams. With its high purity, limited size, near-critical density, and high-repetitionmore » rate capability, this target is promising for future applications.« less

  8. High-intensity laser-accelerated ion beam produced from cryogenic micro-jet target

    SciTech Connect

    Gauthier, M.; Kim, J. B.; Curry, C. B.; Aurand, B.; Gamboa, E. J.; Göde, S.; Goyon, C.; Hazi, A.; Kerr, S.; Pak, A.; Propp, A.; Ramakrishna, B.; Ruby, J.; Willi, O.; Williams, G. J.; Rödel, C.; Glenzer, S. H.

    2016-08-24

    Here, we report on the successful operation of a newly developed cryogenic jet target at high intensity laser-irradiation. Using the frequency-doubled Titan short pulse laser system at Jupiter Laser Facility, Lawrence Livermore National Laboratory, we demonstrate the generation of a pure proton beam a with maximum energy of 2 MeV. Furthermore, we record a quasi-monoenergetic peak at 1.1 MeV in the proton spectrum emitted in the laser forward direction suggesting an alternative acceleration mechanism. Using a solid-density mixed hydrogen-deuterium target, we are also able to produce pure proton-deuteron ion beams. With its high purity, limited size, near-critical density, and high-repetition rate capability, this target is promising for future applications.

  9. Agile manufacturing prototyping system (AMPS)

    SciTech Connect

    Garcia, P.

    1998-05-09

    The Agile Manufacturing Prototyping System (AMPS) is being integrated at Sandia National Laboratories. AMPS consists of state of the industry flexible manufacturing hardware and software enhanced with Sandia advancements in sensor and model based control; automated programming, assembly and task planning; flexible fixturing; and automated reconfiguration technology. AMPS is focused on the agile production of complex electromechanical parts. It currently includes 7 robots (4 Adept One, 2 Adept 505, 1 Staubli RX90), conveyance equipment, and a collection of process equipment to form a flexible production line capable of assembling a wide range of electromechanical products. This system became operational in September 1995. Additional smart manufacturing processes will be integrated in the future. An automated spray cleaning workcell capable of handling alcohol and similar solvents was added in 1996 as well as parts cleaning and encapsulation equipment, automated deburring, and automated vision inspection stations. Plans for 1997 and out years include adding manufacturing processes for the rapid prototyping of electronic components such as soldering, paste dispensing and pick-and-place hardware.

  10. Optimizing the electron beam parameters for head-on beam-beam compensation in RHIC

    SciTech Connect

    Luo, Y.; Fischer, W.; Pikin, A.; Gu, X.

    2011-03-28

    Head-on beam-beam compensation is adopted to compensate the large beam-beam tune spread from the protonproton interactions at IP6 and IP8 in the Relativistic Heavy Ion Collider (RHIC). Two e-lenses are being built and to be in stalled near IP10 in the end of 2011. In this article we perform numeric simulation to investigate the effect of the electron beam parameters on the proton dynamics. The electron beam parameters include its transverse profile, size, current, offset and random errors in them. In this article we studied the effect of the electron beam parameters on the proton dynamics. The electron beam parameters include its transverse shape, size, current, offset and their random errors. From the study, we require that the electron beam size can not be smaller than the proton beam's. And the random noise in the electron current should be better than 0.1%. The offset of electron beam w.r.t. the proton beam center is crucial to head-on beam-beam compensation. Its random errors should be below {+-}8{micro}m.

  11. [INVITED] Ultrafast laser micro- and nano-processing with nondiffracting and curved beams. Invited paper for the section : Hot topics in Ultrafast Lasers

    NASA Astrophysics Data System (ADS)

    Courvoisier, F.; Stoian, R.; Couairon, A.

    2016-06-01

    Ultrafast laser materials processing has undergone an important change with the development of non-diffracting beams. These beams enable overcoming many of the difficulties usually encountered with standard Gaussian-beam focusing in materials. We review the techniques of non-diffracting and accelerating beam shaping that generates lines, tubes or curved segments of focused light on distances that exceed the Gaussian Rayleigh range by several orders of magnitude. We review the benefits and applications of nondiffracting beams for laser micro- and nano-processing in the general context of materials processing with ultrashort pulses in the filamentation regime. We highlight applications on ultra-high aspect ratio nano-drilling and direct laser processing along curves.

  12. Modeling and simulation of high-current vacuum arc considering the micro process of anode vapor

    NASA Astrophysics Data System (ADS)

    Wang, Lijun; Huang, Xiaolong; Zhang, Xiao; Jia, Shenli

    2017-03-01

    In vacuum arc (VA), when the arc current is very high (usually in the tens of kilo-ampere), the heat flux density injecting into an anode is larger and leads to a higher anode temperature with the increasing of current. The strong anode evaporation drives the evaporated atoms from the anode surface to the arc column. Simultaneously, the anode evaporated atoms impact with the cathode plasma, and then the micro processes as ionization and recombination between anode atoms and plasma will happen. In this paper, the two fluid three-dimensional (3D) magneto-hydro-dynamic (MHD) model of VA considering ionization and recombination processes is built, and the influence of the anode vapor and its micro processes on the arc column is obtained by solving the two fluid MHD equations, which control anode neutral atoms and cathode plasma, respectively. In the model, the ionization of neutral atoms and the recombination of ions are both considered, the mass, momentum and energy exchange caused by the ionization and recombination processes are also considered. Moreover, the influence of ionization and recombination processes on the electromagnetic process of VA is also considered in the model. By numerical simulation, the anode vapor distribution, cathode plasma distribution and VA distribution, such as density, temperature, pressure, etc, are all obtained, and the parameters related to ionization and recombination processes are also obtained. When the anode temperature is high enough, the anode neutral vapor will enter into the arc column, and strong ionization happens at the interface between anode vapor and cathode plasma. Then, the anode vapor will be quickly ionized (usually smaller than a few microseconds) and generate a lot of ions (usually higher than 1021 m‑3 orders of magnitude). The anode neutral vapor has the same temperature with the anode surface, which is much lower than the temperature of the arc column, so the anode neutral vapor obviously has a cooling effect

  13. Laboratory-based micro-X-ray fluorescence setup using a von Hamos crystal spectrometer and a focused beam X-ray tube.

    PubMed

    Kayser, Y; Błachucki, W; Dousse, J-Cl; Hoszowska, J; Neff, M; Romano, V

    2014-04-01

    The high-resolution von Hamos bent crystal spectrometer of the University of Fribourg was upgraded with a focused X-ray beam source with the aim of performing micro-sized X-ray fluorescence (XRF) measurements in the laboratory. The focused X-ray beam source integrates a collimating optics mounted on a low-power micro-spot X-ray tube and a focusing polycapillary half-lens placed in front of the sample. The performances of the setup were probed in terms of spatial and energy resolution. In particular, the fluorescence intensity and energy resolution of the von Hamos spectrometer equipped with the novel micro-focused X-ray source and a standard high-power water-cooled X-ray tube were compared. The XRF analysis capability of the new setup was assessed by measuring the dopant distribution within the core of Er-doped SiO2 optical fibers.

  14. Beam hardening artifacts in micro-computed tomography scanning can be reduced by X-ray beam filtration and the resulting images can be used to accurately measure BMD.

    PubMed

    Meganck, Jeffrey A; Kozloff, Kenneth M; Thornton, Michael M; Broski, Stephen M; Goldstein, Steven A

    2009-12-01

    Bone mineral density (BMD) measurements are critical in many research studies investigating skeletal integrity. For pre-clinical research, micro-computed tomography (microCT) has become an essential tool in these studies. However, the ability to measure the BMD directly from microCT images can be biased by artifacts, such as beam hardening, in the image. This three-part study was designed to understand how the image acquisition process can affect the resulting BMD measurements and to verify that the BMD measurements are accurate. In the first part of this study, the effect of beam hardening-induced cupping artifacts on BMD measurements was examined. In the second part of this study, the number of bones in the X-ray path and the sampling process during scanning was examined. In the third part of this study, microCT-based BMD measurements were compared with ash weights to verify the accuracy of the measurements. The results indicate that beam hardening artifacts of up to 32.6% can occur in sample sizes of interest in studies investigating mineralized tissue and affect mineral density measurements. Beam filtration can be used to minimize these artifacts. The results also indicate that, for murine femora, the scan setup can impact densitometry measurements for both cortical and trabecular bone and morphologic measurements of trabecular bone. Last, when a scan setup that minimized all of these artifacts was used, the microCT-based measurements correlated well with ash weight measurements (R(2)=0.983 when air was excluded), indicating that microCT can be an accurate tool for murine bone densitometry.

  15. Model of convection mass transfer in titanium alloy at low energy high current electron beam action

    NASA Astrophysics Data System (ADS)

    Sarychev, V. D.; Granovskii, A. Yu; Nevskii, S. A.; Konovalov, S. V.; Gromov, V. E.

    2017-01-01

    The convection mixing model is proposed for low-energy high-current electron beam treatment of titanium alloys, pre-processed by heterogeneous plasma flows generated via explosion of carbon tape and powder TiB2. The model is based on the assumption vortices in the molten layer are formed due to the treatment by concentrated energy flows. These vortices evolve as the result of thermocapillary convection, arising because of the temperature gradient. The calculation of temperature gradient and penetration depth required solution of the heat problem with taking into account the surface evaporation. However, instead of the direct heat source the boundary conditions in phase transitions were changed in the thermal conductivity equation, assuming the evaporated material takes part in the heat exchange. The data on the penetration depth and temperature distribution are used for the thermocapillary model. The thermocapillary model embraces Navier-Stocks and convection heat transfer equations, as well as the boundary conditions with the outflow of evaporated material included. The solution of these equations by finite elements methods pointed at formation of a multi-vortices structure when electron-beam treatment and its expansion over new zones of material. As the result, strengthening particles are found at the depth exceeding manifold their penetration depth in terms of the diffusion mechanism.

  16. High current pulsed electron beam treatment of AZ31 Mg alloy

    SciTech Connect

    Gao Bo; Hao Shengzhi; Zou Jianxin; Grosdidier, Thierry; Jiang Limin; Zhou Jiyang; Dong Chuang

    2005-11-15

    This paper reports, for the first time, an analysis of the effect of High Current Pulsed Electron Beam (HCPEB) on a Mg alloy. The AZ31 alloy was HCPEB treated in order to see the potential of this fairly recent technique in modifying its wear resistance. For the 2.5 J/cm{sup 2} beam energy density used in the present work, the evaporation mode was operative and led to the formation of a ''wavy'' surface and the absence of eruptive microcraters. The selective evaporation of Mg over Al led to an Al-rich melted surface layer and precipitation hardening from the over saturated solid solution. Due to the increase in hardness of the top surface layer, the friction coefficient values were lowered by more than 20% after the HCPEB treatments, and the wear resistance was drastically (by a factor of 6) improved. The microhardness of the HCPEB samples was also increased significantly down to a depth of about 500 {mu}m, far exceeding the heat-affected zone (about 40 {mu}m). This is due to the effect of the propagation of the shockwave associated with this HCPEB treatment.

  17. Wide Dynamic Range Front-end Electronics for Beam Current and Position Measurement

    SciTech Connect

    Rawnsley, W. R.; Potter, R. J.; Verzilov, V. A.; Root, L.

    2006-11-20

    An Analog Devices log detector, AD8306, and a Digital Signal Processor (DSP), ADSP-21992, have been found useful for building wide dynamic range, accurate and inexpensive front-end electronics to measure and process the RF signals from TRIUMF's beam monitors. The high-precision log detector has a useful dynamic range of over 100 dB. The 160 MHz mixed-signal DSP is used to digitize the log detector output, linearize it via a lookup table, perform temperature compensation, and remove the variable duty cycle 1 kHz pulse structure of the beam. This approach has been applied to two types of devices in a 500 MeV proton beamline. The 0.1% DC to CW total current monitor is based on a capacitive pickup resonant at 46.11 MHz, the second harmonic of the bunch frequency. The DSP software provides low pass filtering, calculates the antilog of the data and passes the output to a CAMAC input register. The BPM electronics process data from inductive pickup loops. The DSP controls a GaAs switch which multiplexes signals from four adjacent pickups to a single log detector. The DSP performs difference-over-sum or log-ratio data analysis along with averaging over an arbitrary number of samples.

  18. A high-current electron gun for the electron beam ion trap at the National Superconducting Cyclotron Laboratory

    SciTech Connect

    Schwarz, S. Baumann, T. M.; Kittimanapun, K.; Lapierre, A.; Snyder, A.

    2014-02-15

    The Electron Beam Ion Trap (EBIT) in NSCL’s reaccelerator ReA uses continuous ion injection and accumulation. In order to maximize capture efficiency and minimize breeding time into high charge states, the EBIT requires a high-current/high current-density electron beam. A new electron gun insert based on a concave Ba-dispenser cathode has been designed and built to increase the current transmitted through the EBIT’s superconducting magnet. With the new insert, stable EBIT operating conditions with 0.8 A of electron beam have been established. The design of the electron gun is presented together with calculated and measured perveance data. In order to assess the experimental compression of the electron beam, a pinhole CCD camera has been set up to measure the electron beam radius. The camera observes X-rays emitted from highly charged ions, excited by the electron beam. Initial tests with this camera setup will be presented. They indicate that a current density of 640 A/cm{sup 2} has been reached when the EBIT magnet was operated at 4 T.

  19. Degradation and decoloration of textiles wastewater by electron beam irradiation: Effect of energy, current and absorbed dose

    SciTech Connect

    Bakar, Khomsaton Abu; Zulkafli,; Hashim, Siti A'aisah; Ahmad, Pauzi

    2014-09-03

    In this study, electron beam accelerator (EB) was used to treat textiles wastewater from Rawang Industrial Park, Selangor. The objectives were to determine effective energy, beam current and absorbed dose required for decoloration and degradation of the textiles effluent. The textiles effluent was irradiated in a batch with various energy of 1MeV to 3MeV at constant beam current of 30mA. It was observed that removal of color and COD increases with higher beam energy. The EB energy of 1MeV effectively to removed 58% color and 19% COD. For textile effluent sample irradiated at fix energy of 1MeV and 3Mev but at different beam current 10mA, 20mA and 30mA. It was observed that removal of color and COD increases with the increased of beam current at each energy. However removal of color was significantly better at 1Mev as compared to 3Mev. In the case of textiles effluent, irradiated at doses of 17, 20,25,30, 35, 100 and 200kGy using 30 kW power of EB (1Mev, 30mA), results shows removal of BOD{sub 5}, COD and color were in the range 9%-33%, 14%-38% and 43%-78% respectively.

  20. Degradation and decoloration of textiles wastewater by electron beam irradiation: Effect of energy, current and absorbed dose

    NASA Astrophysics Data System (ADS)

    Bakar, Khomsaton Abu; Ahmad, Pauzi; Zulkafli, Hashim, Siti A'aisah

    2014-09-01

    In this study, electron beam accelerator (EB) was used to treat textiles wastewater from Rawang Industrial Park, Selangor. The objectives were to determine effective energy, beam current and absorbed dose required for decoloration and degradation of the textiles effluent. The textiles effluent was irradiated in a batch with various energy of 1MeV to 3MeV at constant beam current of 30mA. It was observed that removal of color and COD increases with higher beam energy. The EB energy of 1MeV effectively to removed 58% color and 19% COD. For textile effluent sample irradiated at fix energy of 1MeV and 3Mev but at different beam current 10mA, 20mA and 30mA. It was observed that removal of color and COD increases with the increased of beam current at each energy. However removal of color was significantly better at 1Mev as compared to 3Mev. In the case of textiles effluent, irradiated at doses of 17, 20,25,30, 35, 100 and 200kGy using 30 kW power of EB (1Mev, 30mA), results shows removal of BOD5, COD and color were in the range 9%-33%, 14%-38% and 43%-78% respectively.

  1. CONTROL SYSTEM FOR THE LITHIUM BEAM EDGE PLASMA CURRENT DENSITY DIAGNOSTIC ON THE DIII-D TOKAMAK

    SciTech Connect

    PEAVY,J.J; CARY,W.P; THOMAS,D.M; KELLMAN,D.H; HOYT,D.M; DELAWARE,S.W; PRONKO,S.G.E; HARRIS,T.E

    2003-10-01

    OAK-B135 An edge plasma current density diagnostic employing a neutralized lithium ion beam system has been installed on the DIII-D tokamak. The lithium beam control system is designed around a GE Fanuc 90-30 series PLC and Cimplicity{reg_sign} HMI (Human Machine Interface) software. The control system operates and supervises a collection of commercial and in-house designed high voltage power supplies for beam acceleration and focusing, filament and bias power supplies for ion creation, neutralization, vacuum, triggering, and safety interlocks. This paper provides an overview of the control system, while highlighting innovative aspects including its remote operation, pulsed source heating and pulsed neutralizer heating, optimizing beam regulation, and beam ramping, ending with a discussion of its performance.

  2. A modified beam-to-earth transformation to measure short-wavelength internal waves with an acoustic Doppler current profiler

    USGS Publications Warehouse

    Scotti, A.; Butman, B.; Beardsley, R.C.; Alexander, P.S.; Anderson, S.

    2005-01-01

    The algorithm used to transform velocity signals from beam coordinates to earth coordinates in an acoustic Doppler current profiler (ADCP) relies on the assumption that the currents are uniform over the horizontal distance separating the beams. This condition may be violated by (nonlinear) internal waves, which can have wavelengths as small as 100-200 m. In this case, the standard algorithm combines velocities measured at different phases of a wave and produces horizontal velocities that increasingly differ from true velocities with distance from the ADCP. Observations made in Massachusetts Bay show that currents measured with a bottom-mounted upward-looking ADCP during periods when short-wavelength internal waves are present differ significantly from currents measured by point current meters, except very close to the instrument. These periods are flagged with high error velocities by the standard ADCP algorithm. In this paper measurements from the four spatially diverging beams and the backscatter intensity signal are used to calculate the propagation direction and celerity of the internal waves. Once this information is known, a modified beam-to-earth transformation that combines appropriately lagged beam measurements can be used to obtain current estimates in earth coordinates that compare well with pointwise measurements. ?? 2005 American Meteorological Society.

  3. X-ray micro-beam techniques and phase contrast tomography applied to biomaterials

    NASA Astrophysics Data System (ADS)

    Fratini, Michela; Campi, Gaetano; Bukreeva, Inna; Pelliccia, Daniele; Burghammer, Manfred; Tromba, Giuliana; Cancedda, Ranieri; Mastrogiacomo, Maddalena; Cedola, Alessia

    2015-12-01

    A deeper comprehension of the biomineralization (BM) process is at the basis of tissue engineering and regenerative medicine developments. Several in-vivo and in-vitro studies were dedicated to this purpose via the application of 2D and 3D diagnostic techniques. Here, we develop a new methodology, based on different complementary experimental techniques (X-ray phase contrast tomography, micro-X-ray diffraction and micro-X-ray fluorescence scanning technique) coupled to new analytical tools. A qualitative and quantitative structural investigation, from the atomic to the micrometric length scale, is obtained for engineered bone tissues. The high spatial resolution achieved by X-ray scanning techniques allows us to monitor the bone formation at the first-formed mineral deposit at the organic-mineral interface within a porous scaffold. This work aims at providing a full comprehension of the morphology and functionality of the biomineralization process, which is of key importance for developing new drugs for preventing and healing bone diseases and for the development of bio-inspired materials.

  4. 2D beam hardening correction for micro-CT of immersed hard tissue

    NASA Astrophysics Data System (ADS)

    Davis, Graham; Mills, David

    2016-10-01

    Beam hardening artefacts arise in tomography and microtomography with polychromatic sources. Typically, specimens appear to be less dense in the center of reconstructions because as the path length through the specimen increases, so the X-ray spectrum is shifted towards higher energies due to the preferential absorption of low energy photons. Various approaches have been taken to reduce or correct for these artefacts. Pre-filtering the X-ray beam with a thin metal sheet will reduce soft energy X-rays and thus narrow the spectrum. Correction curves can be applied to the projections prior to reconstruction which transform measured attenuation with polychromatic radiation to predicted attenuation with monochromatic radiation. These correction curves can be manually selected, iteratively derived from reconstructions (this generally works where density is assumed to be constant) or derived from a priori information about the X-ray spectrum and specimen composition. For hard tissue specimens, the latter approach works well if the composition is reasonably homogeneous. In the case of an immersed or embedded specimen (e.g., tooth or bone) the relative proportions of mineral and "organic" (including medium and plastic container) species varies considerably for different ray paths and simple beam hardening correction does not give accurate results. By performing an initial reconstruction, the total path length through the container can be determined. By modelling the X-ray properties of the specimen, a 2D correction transform can then be created such that the predicted monochromatic attenuation can be derived as a function of both the measured polychromatic attenuation and the container path length.

  5. BOILING AUGMENTATION WITH MICRO/NANOSTRUCTURED SURFACES: CURRENT STATUS AND RESEARCH OUTLOOK

    SciTech Connect

    Bhavnani, S; Narayanan, V; Qu, WL; Jensen, M; Kandlikar, S; Kim, J; Thome, J

    2014-07-23

    Advances in the development of micro- and nanostructured surfaces have enabled tremendous progress in delineation of mechanisms in boiling heat transfer and have propelled the rapid enhancement of heat transfer rates. This area of research is poised to make great strides toward tailoring surface features to produce dramatically improved thermal performance. A workshop was held in April 2013 to provide a review of the current state-of-the-art and to develop near-term and long-term goals for the boiling augmentation community. A brief historical perspective and primary findings are presented in this article. Though impressive gains have been made in enhancement of boiling heat transport, there still remain several unknowns such as the mechanisms that affect critical heat flux and optimization of surfaces for boiling heat transport. The promise of improved spatial resolution of optical techniques should improve knowledge of near-surface mechanisms. Standardization of experimental test sections and procedures has emerged as a critical issue that needs to be addressed immediately.

  6. WE-A-207-02: Electron Beam Therapy - Current Status and Future Directions

    SciTech Connect

    Wu, Q.

    2015-06-15

    In memory of the significant contribution of Dr. Jacques Ovadia to electron beam techniques, this session will review recent, advanced techniques which are reinvigorating the science of electron beam radiation therapy. Recent research efforts in improving both the applicability and quality of the electron beam therapy will be discussed, including modulated electron beam radiotherapy (MERT) and dynamic electron arc radiotherapy (DEAR). Learning Objectives: To learn about recent advances in electron beam therapy, including modulated electron beam therapy and dynamic electron arc therapy (DEAR). Put recent advances in the context of work that Dr. Ovadia pursued during his career in medical physics.

  7. Reducing adhesion energy of micro-relay electrodes by ion beam synthesized oxide nanolayers

    NASA Astrophysics Data System (ADS)

    Saha, Bivas; Peschot, Alexis; Osoba, Benjamin; Ko, Changhyun; Rubin, Leonard; Liu, Tsu-JaeKing; Wu, Junqiao

    2017-03-01

    Reduction in the adhesion energy of contacting metal electrode surfaces in nano-electro-mechanical switches is crucial for operation with low hysteresis voltage. We demonstrate that by forming thin layers of metal-oxides on metals such as Ru and W, the adhesion energy can be reduced by up to a factor of ten. We employ a low-energy ion-beam synthesis technique and subsequent thermal annealing to form very thin layers (˜2 nm) of metal-oxides (such as RuO2 and WOx) on Ru and W metal surfaces and quantify the adhesion energy using an atomic force microscope with microspherical tips.

  8. Current status of dental caries diagnosis using cone beam computed tomography

    PubMed Central

    Park, Young-Seok; Ahn, Jin-Soo; Kwon, Ho-Beom

    2011-01-01

    Purpose The purpose of this article is to review the current status of dental caries diagnosis using cone beam computed tomography (CBCT). Materials and Methods An online PubMed search was performed to identify studies on caries research using CBCT. Results Despite its usefulness, there were inherent limitations in the detection of caries lesions through conventional radiograph mainly due to the two-dimensional (2D) representation of caries lesions. Several efforts were made to investigate the three-dimensional (3D) image of lesion, only to gain little popularity. Recently, CBCT was introduced and has been used for diagnosis of caries in several reports. Some of them maintained the superiority of CBCT systems, however it is still under controversies. Conclusion The CBCT systems are promising, however they should not be considered as a primary choice of caries diagnosis in everyday practice yet. Further studies under more standardized condition should be performed in the near future. PMID:21977474

  9. Microstructure Analysis of HPb59-1 Brass Induced by High Current Pulsed Electron Beam

    NASA Astrophysics Data System (ADS)

    Lyu, Jike; Gao, Bo; Hu, Liang; Lu, Shuaidan; Tu, Ganfeng

    2016-08-01

    In this paper, the effects of high current pulsed electron beam (HCPEB) on the microstructure evolution of casting HPb59-1 (Cu 57.1 mass%, Pb 1.7 mass% and Zn balance) alloy were investigated. The results showed a "wavy" surface which was formed with Pb element existing in the forms of stacking block and microparticles on the top surface layer after treatment. Nanocrystalline structures including Pb grains and two phases (α and β) were formed on the top remelted layer and their sizes were all less than 100 nm. The disordered β phase was generated in the surface layer after HCPEB treatment, which is beneficial for the improvement of surface properties. Meanwhile, there was a large residual stress on the alloy surface, along with the appearance of microcracks, and the preferred orientations of grains also changed.

  10. Quantitative description of the properties of extended defects in silicon by means of electron- and laser-beam-induced currents

    SciTech Connect

    Shabelnikova, Ya. L. Yakimov, E. B.; Nikolaev, D. P.; Chukalina, M. V.

    2015-06-15

    A solar cell on a wafer of multicrystalline silicon containing grain boundaries was studied by the induced-current method. The sample was scanned by an electron beam and by a laser beam at two wavelengths (980 and 635 nm). The recorded induced-current maps were aligned by means of a specially developed code, that enabled to analyze the same part of the grain boundary for three types of measurements. Optimization of the residual between simulated induced-current profiles and those obtained experimentally yielded quantitative estimates of the characteristics of a sample and its defects: the diffusion length of minority carriers and recombination velocity at the grain boundary.

  11. Simulative research on the expansion of cathode plasma in high-current electron beam diode

    SciTech Connect

    Xu Qifu; Liu Lie

    2012-09-15

    The expansion of cathode plasma has long been recognized as a limiting factor in the impedance lifetime of high-current electron beam diode. Realistic modeling of such plasma is of great necessity in order to discuss the dynamics of cathode plasma. Using the method of particle-in-cell, the expansion of cathode plasma is simulated in this paper by a scaled-down diode model. It is found that the formation of cathode plasma increases the current density in the diode. This consequently leads to the decrease of the potential at plasma front. Once the current density has been increased to a certain value, the potential at plasma front would then be equal to or lower than the plasma potential. Then the ions would move towards the anode, and the expansion of cathode plasma is thereby formed. Different factors affecting the plasma expansion velocity are discussed in this paper. It is shown that the decrease of proton genatation rate has the benefit of reducing the plasma expansion velocity.

  12. The current status of cone beam computed tomography imaging in orthodontics

    PubMed Central

    Kapila, S; Conley, R S; Harrell, W E

    2011-01-01

    Cone beam CT (CBCT) has become an increasingly important source of three dimensional (3D) volumetric data in clinical orthodontics since its introduction into dentistry in 1998. The purpose of this manuscript is to highlight the current understanding of, and evidence for, the clinical use of CBCT in orthodontics, and to review the findings to answer clinically relevant questions. Currently available information from studies using CBCT can be organized into five broad categories: 1, the assessment of CBCT technology; 2, its use in craniofacial morphometric analyses; 3, incidental and missed findings; 4, analysis of treatment outcomes; and 5, efficacy of CBCT in diagnosis and treatment planning. The findings in these topical areas are summarized, followed by current indications and protocols for the use of CBCT in specific cases. Despite the increasing popularity of CBCT in orthodontics, and its advantages over routine radiography in specific cases, the effects of information derived from these images in altering diagnosis and treatment decisions has not been demonstrated in several types of cases. It has therefore been recommended that CBCT be used in select cases in which conventional radiography cannot supply satisfactory diagnostic information; these include cleft palate patients, assessment of unerupted tooth position, supernumerary teeth, identification of root resorption and for planning orthognathic surgery. The need to image other types of cases should be made on a case-by-case basis following an assessment of benefits vs risks of scanning in these situations. PMID:21159912

  13. The current status of cone beam computed tomography imaging in orthodontics.

    PubMed

    Kapila, S; Conley, R S; Harrell, W E

    2011-01-01

    Cone beam CT (CBCT) has become an increasingly important source of three dimensional (3D) volumetric data in clinical orthodontics since its introduction into dentistry in 1998. The purpose of this manuscript is to highlight the current understanding of, and evidence for, the clinical use of CBCT in orthodontics, and to review the findings to answer clinically relevant questions. Currently available information from studies using CBCT can be organized into five broad categories: 1, the assessment of CBCT technology; 2, its use in craniofacial morphometric analyses; 3, incidental and missed findings; 4, analysis of treatment outcomes; and 5, efficacy of CBCT in diagnosis and treatment planning. The findings in these topical areas are summarized, followed by current indications and protocols for the use of CBCT in specific cases. Despite the increasing popularity of CBCT in orthodontics, and its advantages over routine radiography in specific cases, the effects of information derived from these images in altering diagnosis and treatment decisions has not been demonstrated in several types of cases. It has therefore been recommended that CBCT be used in select cases in which conventional radiography cannot supply satisfactory diagnostic information; these include cleft palate patients, assessment of unerupted tooth position, supernumerary teeth, identification of root resorption and for planning orthognathic surgery. The need to image other types of cases should be made on a case-by-case basis following an assessment of benefits vs risks of scanning in these situations.

  14. Electron Beam Return-Current Losses in Solar Flares: Initial Comparison of Analytical and Numerical Results

    NASA Technical Reports Server (NTRS)

    Holman, Gordon

    2010-01-01

    Accelerated electrons play an important role in the energetics of solar flares. Understanding the process or processes that accelerate these electrons to high, nonthermal energies also depends on understanding the evolution of these electrons between the acceleration region and the region where they are observed through their hard X-ray or radio emission. Energy losses in the co-spatial electric field that drives the current-neutralizing return current can flatten the electron distribution toward low energies. This in turn flattens the corresponding bremsstrahlung hard X-ray spectrum toward low energies. The lost electron beam energy also enhances heating in the coronal part of the flare loop. Extending earlier work by Knight & Sturrock (1977), Emslie (1980), Diakonov & Somov (1988), and Litvinenko & Somov (1991), I have derived analytical and semi-analytical results for the nonthermal electron distribution function and the self-consistent electric field strength in the presence of a steady-state return-current. I review these results, presented previously at the 2009 SPD Meeting in Boulder, CO, and compare them and computed X-ray spectra with numerical results obtained by Zharkova & Gordovskii (2005, 2006). The phYSical significance of similarities and differences in the results will be emphasized. This work is supported by NASA's Heliophysics Guest Investigator Program and the RHESSI Project.

  15. Design and characterization of the annular cathode high current pulsed electron beam source for circular components

    NASA Astrophysics Data System (ADS)

    Jiang, Wei; Wang, Langping; Wang, Xiaofeng

    2016-08-01

    In order to irradiate circular components with high current pulsed electron beam (HCPEB), an annular cathode based on carbon fiber bunches was designed and fabricated. Using an acceleration voltage of 25 kV, the maximum pulsed irradiation current and energy of this annular cathode can reach 7.9 kA and 300 J, respectively. The irradiation current density distribution of the annular cathode HCPEB source measured along the circumferential direction shows that the annular cathode has good emission uniformity. In addition, four 9310 steel substrates fixed uniformly along the circumferential direction of a metal ring substrate were irradiated by this annular cathode HCPEB source. The surface and cross-section morphologies of the irradiated samples were characterized by scanning electron microscopy (SEM). SEM images of the surface reveal that crater and surface undulation have been formed, which hints that the irradiation energy of the HCPEB process is large enough for surface modification of 9310 steel. Meanwhile, SEM cross-section images exhibit that remelted layers with a thickness of about 5.4 μm have been obtained in all samples, which proves that a good practical irradiation uniformity can be achieved by this annular cathode HCPEB source.

  16. A superconducting quadrupole array for transport of multiple high current beams

    SciTech Connect

    Faltens, A.; Shuman, D.

    1999-11-01

    We present a conceptual design of a superconducting quadrupole magnet array for the side-by-side transport of multiple high current particle beams in induction linear accelerators. The magnetic design uses a modified cosine 20 current distribution inside a square cell boundary. Each interior magnet's neighbors serve as the return flux paths and the poles are placed as close as possible to each other to facilitate this. No iron is present in the basic 2-D magnetic design; it will work at any current level without correction windings. Special 1/8th quadrupoles are used along the transverse periphery of the array to contain and channel flux back into the array, making every channel look as part of an infinite array. This design provides a fixed dimension array boundary equal to the quadrupole radius that can be used for arrays of any number of quadrupole channels, at any field level. More importantly, the design provides magnetic field separation between the array and the induction cores which may be surrounding it. Flux linkage between these two components can seriously affect the operation of both of them.

  17. High aspect ratio micro-explosions in the bulk of sapphire generated by femtosecond Bessel beams

    PubMed Central

    Rapp, L.; Meyer, R.; Giust, R.; Furfaro, L.; Jacquot, M.; Lacourt, P. A.; Dudley, J. M.; Courvoisier, F.

    2016-01-01

    Femtosecond pulses provide an extreme degree of confinement of light matter-interactions in high-bandgap materials because of the nonlinear nature of ionization. It was recognized very early on that a highly focused single pulse of only nanojoule energy could generate spherical voids in fused silica and sapphire crystal as the nanometric scale plasma generated has energy sufficient to compress the material around it and to generate new material phases. But the volumes of the nanometric void and of the compressed material are extremely small. Here we use single femtosecond pulses shaped into high-angle Bessel beams at microjoule energy, allowing for the creation of very high 100:1 aspect ratio voids in sapphire crystal, which is one of the hardest materials, twice as dense as glass. The void volume is 2 orders of magnitude higher than those created with Gaussian beams. Femtosecond and picosecond illumination regimes yield qualitatively different damage morphologies. These results open novel perspectives for laser processing and new materials synthesis by laser-induced compression. PMID:27669676

  18. Rocket propulsion by thermonuclear micro-bombs ignited with intense relativistic electron beams.

    NASA Technical Reports Server (NTRS)

    Winterberg, F.

    1971-01-01

    Discussion of a method for the ignition of a thermonuclear microbomb by means of an intense relativistic electron beam with regard to its potential application to rocket propulsion. With such a system, exhaust velocities up to 1000 km/sec, corresponding to a specific impulse of 100,000 sec, seem to be within the realm of possibility. The rocket is propelled by a chain of thermonuclear microbombs exploded in a concave magnetic mirror produced by superconducting field coils. The magnetic pressure of the field reflects the fireball generated by the explosion. For the large capacitor bank required to generate the intense relativistic electron beam, a desirable lightweight design may be possible through use of ferroelectric materials. Because of the high cost of the T-D and He 3-D thermonuclear material, the system has to be optimized by minimizing the T-D and He 3-D consumption by a proper TD and He 3-D fuel to hydrogen propellant mass ratio, leading to a larger total system mass than would be absolutely necessary.

  19. Dynamic Characteristics of Micro-Beams Considering the Effect of Flexible Supports

    PubMed Central

    Zhong, Zuo-Yang; Zhang, Wen-Ming; Meng, Guang

    2013-01-01

    Normally, the boundaries are assumed to allow small deflections and moments for MEMS beams with flexible supports. The non-ideal boundary conditions have a significant effect on the qualitative dynamical behavior. In this paper, by employing the principle of energy equivalence, rigorous theoretical solutions of the tangential and rotational equivalent stiffness are derived based on the Boussinesq's and Cerruti's displacement equations. The non-dimensional differential partial equation of the motion, as well as coupled boundary conditions, are solved analytically using the method of multiple time scales. The closed-form solution provides a direct insight into the relationship between the boundary conditions and vibration characteristics of the dynamic system, in which resonance frequencies increase with the nonlinear mechanical spring effect but decrease with the effect of flexible supports. The obtained results of frequencies and mode shapes are compared with the cases of ideal boundary conditions, and the differences between them are contrasted on frequency response curves. The influences of the support material property on the equivalent stiffness and resonance frequency shift are also discussed. It is demonstrated that the proposed model with the flexible supports boundary conditions has significant effect on the rigorous quantitative dynamical analysis of the MEMS beams. Moreover, the proposed analytical solutions are in good agreement with those obtained from finite element analyses.

  20. Note: Measurement of extreme-short current pulse duration of runaway electron beam in atmospheric pressure air

    SciTech Connect

    Tarasenko, V. F.; Rybka, D. V.; Burachenko, A. G.; Lomaev, M. I.; Balzovsky, E. V.

    2012-08-15

    This note reports the time-amplitude characteristic of the supershort avalanche electron beam with up to 20 ps time resolution. For the first time it is shown that the electron beam downstream of small-diameter diaphragms in atmospheric pressure air has a complex structure which depends on the interelectrode gap width and cathode design. With a spherical cathode and collimator the minimum duration at half maximum of the supershort avalanche electron beam current pulse was shown to be {approx}25 ps. The minimum duration at half maximum of one peak in the pulses with two peaks can reach {approx}25 ps too.

  1. Note: measurement of extreme-short current pulse duration of runaway electron beam in atmospheric pressure air.

    PubMed

    Tarasenko, V F; Rybka, D V; Burachenko, A G; Lomaev, M I; Balzovsky, E V

    2012-08-01

    This note reports the time-amplitude characteristic of the supershort avalanche electron beam with up to 20 ps time resolution. For the first time it is shown that the electron beam downstream of small-diameter diaphragms in atmospheric pressure air has a complex structure which depends on the interelectrode gap width and cathode design. With a spherical cathode and collimator the minimum duration at half maximum of the supershort avalanche electron beam current pulse was shown to be ~25 ps. The minimum duration at half maximum of one peak in the pulses with two peaks can reach ~25 ps too.

  2. Optimization of Drive-Bunch Current Profile for Enhanced Transformer Ratio in Beam-Driven Acceleration Techniques

    SciTech Connect

    Lemery, F.; Mihalcea, D.; Prokop, C.R.; Piot, P.; /Northern Illinois U. /Fermilab

    2012-07-08

    In recent years, wakefield acceleration has gained attention due to its high acceleration gradients and cost effectiveness. In beam-driven wakefield acceleration, a critical parameter to optimize is the transformer ratio. It has been shown that current shaping of electron beams allows for enhanced (> 2) transformer ratios. In this paper we present the optimization of the pulse shape of the drive bunch for dielectric-wakefield acceleration.

  3. Current role of hybrid CT/angiography system compared with C-arm cone beam CT for interventional oncology

    PubMed Central

    Arai, Y; Inaba, Y; Inoue, M; Nishiofuku, H; Anai, H; Hori, S; Sakaguchi, H; Kichikawa, K

    2014-01-01

    Hybrid CT/angiography (angiography) system and C-arm cone beam CT provide cross-sectional imaging as an adjunct to angiography. Current interventional oncological procedures can be conducted precisely using these two technologies. In this article, several cases using a hybrid CT/angiography system are shown first, and then the advantages and disadvantages of the hybrid CT/angiography and C-arm cone beam CT are discussed with literature reviews. PMID:24968749

  4. Current role of hybrid CT/angiography system compared with C-arm cone beam CT for interventional oncology.

    PubMed

    Tanaka, T; Arai, Y; Inaba, Y; Inoue, M; Nishiofuku, H; Anai, H; Hori, S; Sakaguchi, H; Kichikawa, K

    2014-09-01

    Hybrid CT/angiography (angiography) system and C-arm cone beam CT provide cross-sectional imaging as an adjunct to angiography. Current interventional oncological procedures can be conducted precisely using these two technologies. In this article, several cases using a hybrid CT/angiography system are shown first, and then the advantages and disadvantages of the hybrid CT/angiography and C-arm cone beam CT are discussed with literature reviews.

  5. Protein kinase A-dependent and -independent stimulation of exocytosis by cAMP in mouse pancreatic B-cells.

    PubMed Central

    Renström, E; Eliasson, L; Rorsman, P

    1997-01-01

    1. The mechanisms by which cAMP stimulates Ca(2+)-dependent insulin secretion were investigated by combining measurements of whole-cell Ca2+ currents, the cytoplasmic free Ca2+ concentration ([Ca2+]i) and membrane capacitance in single mouse B-cells maintained in tissue culture. 2. Cyclic AMP stimulated exocytosis > 4-fold in whole-cell experiments in which secretion was evoked by intracellular dialysis with a Ca(2+)-EGTA buffer with a [Ca2+]i of 1.5 microM. This effect was antagonized by inhibitors of protein kinase A (PKA). 3. Photorelease of cAMP from a caged precursor potentiated exocytosis at Ca2+ concentrations which were themselves stimulatory (> or = 60 nM), but was without effect in the complete absence of Ca2+. 4. Elevation of intracellular cAMP (by exposure to forskolin) evoked a 6-fold PKA-dependent enhancement of the maximal exocytotic response (determined as the maximum increase in cell capacitance that could be elicited by a train of depolarizations) in perforated-patch whole-cell recordings. 5. Exocytosis triggered by single depolarizations in standard whole-cell recordings was strongly potentiated by cAMP, but in this case the effect was unaffected by PKA inhibition. 6. When exocytosis was triggered by Ca2+ released from Ca(2+)-NP-EGTA ('caged Ca2+'), cAMP exerted a dual stimulatory effect on secretion: a rapid (initiated within 80 ms) PKA-independent phase and a late PKA-dependent component. 7. We conclude that cAMP stimulates insulin secretion both by increasing the release probability of secretory granules already in the readily releasable pool and by accelerating the refilling of this pool. Images Figure 1 Figure 6 Figure 7 PMID:9234200

  6. Modulation of single hyperpolarization-activated channels (i(f)) by cAMP in the rabbit sino-atrial node.

    PubMed Central

    DiFrancesco, D; Mangoni, M

    1994-01-01

    1. The hyperpolarization-activated 'pacemaker' current (i(f)) was recorded in inside-out patches excised from rabbit sino-atrial (SA) node cell membranes. 2. Single-channel activity could be resolved in patches containing only a few channels; the voltage dependence of single-channel size and single-channel conductance (0.97 pS) were similar to those measured previously in cell-attached conditions. 3. Perfusion of the intracellular side of the patch membrane with 10 microM cAMP facilitated the opening of single i(f) channels on hyperpolarization. The cAMP-induced i(f) current activation occurred without modification of the single-channel conductance. 4. Modification by cAMP of the probability of channel opening was investigated with respect to the latency to first opening during hyperpolarization and in patches containing a large number of channels (macro-patches). First-latency histograms showed that cAMP shifts the probability curve of first openings to shorter times, in agreement with a cAMP-induced facilitation of channel opening. In macro-patches, measurement of the voltage dependence of the open probability by a slow voltage ramp protocol showed that cAMP shifts the probability curve to more positive voltages without modifying its shape. 5. In cell-free macro-patches the normalized open probability curve in control solutions was centred around -121.9 mV, a voltage some 30 mV more negative than in cell-attached macro-patches. Negative shifting of the curve after patch excision could only partly be explained by the removal of intracellular cAMP, and progressed with time during the ramp protocol, suggesting the presence of a run-down process independent from cAMP. PMID:7516974

  7. X-ray micro-beam characterization of a small pixel spectroscopic CdTe detector

    NASA Astrophysics Data System (ADS)

    Veale, M. C.; Bell, S. J.; Seller, P.; Wilson, M. D.; Kachkanov, V.

    2012-07-01

    A small pixel, spectroscopic, CdTe detector has been developed at the Rutherford Appleton Laboratory (RAL) for X-ray imaging applications. The detector consists of 80 × 80 pixels on a 250 μm pitch with 50 μm inter-pixel spacing. Measurements with an 241Am γ-source demonstrated that 96% of all pixels have a FWHM of better than 1 keV while the majority of the remaining pixels have FWHM of less than 4 keV. Using the Diamond Light Source synchrotron, a 10 μm collimated beam of monochromatic 20 keV X-rays has been used to map the spatial variation in the detector response and the effects of charge sharing corrections on detector efficiency and resolution. The mapping measurements revealed the presence of inclusions in the detector and quantified their effect on the spectroscopic resolution of pixels.

  8. Micro-/nanosized cantilever beams and mass sensors under applied axial tensile/compressive force vibrating in vacuum and viscous fluid

    SciTech Connect

    Stachiv, Ivo; Fang, Te-Hua; Chen, Tao-Hsing

    2015-11-15

    Vibrating micro-/nanosized cantilever beams under an applied axial force are the key components of various devices used in nanotechnology. In this study, we perform a complete theoretical investigation of the cantilever beams under an arbitrary value of the axial force vibrating in a specific environment such as vacuum, air or viscous fluid. Based on the results easy accessible expressions enabling one the fast and highly accurate estimations of changes in the Q-factor and resonant frequencies of beam oscillating in viscous fluid caused by the applied axial force are derived and analyzed. It has been also shown that for beam-to-string and string vibrational regimes the mode shape starts to significantly deviate from the one known for a beam without axial force. Moreover, a linear dependency of the vibrational amplitude in resonance on the dimensionless tension parameter has been found. We revealed that only a large axial force, i.e. the string vibrational regime, significantly improves the Q-factor of beams submerged in fluid, while an increase of the axial force in beam and beam-to-string transition regimes has a negligibly small impact on the Q-factor enhancement. Experiments carried out on the carbon nanotubes and nanowires are in a good agreement with present theoretical predictions.

  9. Demonstration of Current Profile Shaping using Double Dog-Leg Emittance Exchange Beam Line at Argonne Wakefield Accelerator

    SciTech Connect

    Ha, Gwanghui; Cho, Moo-Hyun; Conde, Manoel; Doran, Darrell; Gai, Wei; Jing, Chunguang; Kim, Kwang-Je; Liu, Wanming; Namkung, Won; Piot, Philippe; Power, John; Sun, Yin-E; Whiteford, Charles; Wisniewski, Eric; Zholents, Alexander

    2016-06-01

    Emittance exchange (EEX) based longitudinal current profile shaping is the one of the promising current profile shaping technique. This method can generate high quality arbitrary current profiles under the ideal conditions. The double dog-leg EEX beam line was recently installed at the Argonne Wakefield Accelerator (AWA) to explore the shaping capability and confirm the quality of this method. To demonstrate the arbitrary current profile generation, several different transverse masks are applied to generate different final current profiles. The phase space slopes and the charge of incoming beam are varied to observe and suppress the aberrations on the ideal profile. We present current profile shaping results, aberrations on the shaped profile, and its suppression.

  10. Production of high current proton beams using complex H-rich molecules at GSI

    SciTech Connect

    Adonin, A. Barth, W.; Heymach, F.; Hollinger, R.; Vormann, H.; Yakushev, A.

    2016-02-15

    In this contribution, the concept of production of intense proton beams using molecular heavy ion beams from an ion source is described, as well as the indisputable advantages of this technique for operation of the GSI linear accelerator. The results of experimental investigations, including mass-spectra analysis and beam emittance measurements, with different ion beams (CH{sub 3}{sup +},C{sub 2}H{sub 4}{sup +},C{sub 3}H{sub 7}{sup +}) using various gaseous and liquid substances (methane, ethane, propane, isobutane, and iodoethane) at the ion source are summarized. Further steps to improve the ion source and injector performance with molecular beams are depicted.

  11. A study of low-current-density microsecond electron beam diodes

    NASA Astrophysics Data System (ADS)

    Ramirez, J. J.; Cook, D. L.

    1980-09-01

    The performances of various field emitters and plasma-injected diodes for the generation of low-current-density microsecond electron beams to be used in gas laser excitation are investigated and compared. The output from a microsecond high-voltage pulse-forming network was fed to a large-area vacuum diode containing metal-oxide matrix and carbon fiber field emitters and to diodes filled with plasma and containing preformed plasma on the cathode surface. Of the field emitters, a brush cathode made with 10-micron carbon filaments is found to give the best performance, with emission at fields as low as 10 kV/cm, space charge-limited flow established in 60 nsec and apparent gap closure velocities of 1.5 cm/sec. Although substantial control of the diode impedance was obtained when the plasma was allowed to fill the anode-cathode volume, the constraining of the plasma to the cathode surface is found to improve the uniformity and reproducibility of anode current density, with apparent gap closure velocities as low as 2 cm/sec.

  12. Experimental research of different plasma cathodes for generation of high-current electron beams

    SciTech Connect

    Shafir, G.; Kreif, M.; Gleizer, J. Z.; Gleizer, S.; Krasik, Ya. E.; Gunin, A. V.; Kutenkov, O. P.; Rostov, V. V.; Pegel, I. V.

    2015-11-21

    The results of experimental studies of different types of cathodes—carbon-epoxy rods, carbon-epoxy capillary, edged graphite, and metal-dielectric—under the application of high-voltage pulses with an amplitude of several hundreds of kV and pulse duration of several nanoseconds are presented. The best diode performance was achieved with the edged graphite and carbon-epoxy-based cathodes characterized by uniform and fast (<1 ns) formation of explosive emission plasma spots and quasi-constant diode impedance. This result was achieved for both annular cathodes in a strong magnetic field and planar cathodes of a similar diameter (∼2 cm) with no external magnetic field. The cathodes based on carbon-epoxy rods and carbon-epoxy capillaries operating with an average current density up to 1 kA/cm{sup 2} showed insignificant erosion along 10{sup 6} pulses of the generator and the generated electron beam current showed excellent reproducibility in terms of the amplitude and waveform.

  13. Prospects for Edge Current Density Determination Using Li beam on DIII-D

    SciTech Connect

    D.M. Thomas; A.S. Bozek; T.N. Carlstrom; D.K. Finkenthal; R. Jayakumar; M.A. Makowski; D.G. Nilson; T.H. Osborne; B.W. Rice; R.T. Snider

    2000-08-01

    The specific size and structure of the edge current profile has important effects on the MHD stability and ultimate performance of many advanced tokamak (AT) operating modes. This is true for both bootstrap and externally driven currents that may be used to tailor the edge shear. Absent a direct local measurement of j(r), the best alternative is a determination of the poloidal field. Measurements of the precision (0.1-0.01{sup o} in magnetic pitch angle and 1-10 ms) necessary to address issues of stability and control and provide constraints for EFIT are difficult to do in the region of interest ({rho} = 0.9-1.1). Using Zeeman polarization spectroscopy of the 2S-2P lithium resonance line emission from the DIII-D LIBEAM, measurements of the various field components may be made to the necessary precision in exactly the region of interest to these studies. Because of the negligible Stark mixing of the relevant atomic levels, this method of determining j(r) is insensitive to the large local electric fields typically found in enhanced confinement (H-mode) edges, and thus avoids an ambiguity common to Motional Stark Effect (MSE) measurements of B. Key issues for utilizing this technique include good beam quality, an optimum viewing geometry, and a suitable optical pre-filter to isolate the polarized emission line. A prospective diagnostic system for the DIII-D AT program will be described.

  14. Surface composite nanostructures of AZ91 magnesium alloy induced by high current pulsed electron beam treatment

    NASA Astrophysics Data System (ADS)

    Li, M. C.; Hao, S. Z.; Wen, H.; Huang, R. F.

    2014-06-01

    High current pulsed electron beam (HCPEB) treatment was conducted on an AZ91 cast magnesium alloy with accelerating voltage 27 kV, energy density 3 J/cm2 and pulse duration 2.5 μs. The surface microstructure was characterized by optical microscope (OM), X-ray diffraction (XRD), scanning electron microscope (SEM) equipped with energy dispersive spectrometer (EDS), and transmission electron microscope (TEM). The surface corrosion property was tested with electrochemical method in 3.5 wt.% NaCl solution. It is found that after 1 pulse of HCPEB treatment, the initial eutectic α phase and Mg17Al12 particles started to dissolve in the surface modified layer of depth ∼15 μm. When using 15 HCPEB pulses, the Al content in surface layer increased noticeably, and the phase structure was modified as composite nanostructures consisted of nano-grained Mg3.1Al0.9 domains surrounded by network of Mg17Al12 phase. The HCPEB treated samples showed an improved corrosion resistance with cathodic current density decreased by two orders of magnitude as compared to the initial AZ91 alloy.

  15. NASA's Current Directions in the CETDP Micro-Technology Thrust Area

    NASA Technical Reports Server (NTRS)

    Stocky, J.

    2000-01-01

    NASA's program in micro-technologies seeks to develop the advanced technologies needed to reduce the mass of Earth-orbiting and deep-space spacecraft by several orders of magnitude over the next decade.

  16. Simulation of electrostatic turbulence in the plasma sheet boundary layer with electron currents and bean-shaped ion beams

    NASA Technical Reports Server (NTRS)

    Nishikawa, K.-I.; Frank, L. A.; Huang, C. Y.

    1988-01-01

    Plasma data from ISEE-1 show the presence of electron currents as well as energetic ion beams in the plasma sheet boundary layer. Broadband electrostatic noise and low-frequency electromagnetic bursts are detected in the plasma sheet boundary layer, especially in the presence of strong ion flows, currents, and steep spacial gradients in the fluxes of few-keV electrons and ions. Particle simulations have been performed to investigate electrostatic turbulence driven by a cold electron beam and/or ion beams with a bean-shaped velocity distribution. The simulation results show that the counterstreaming ion beams as well as the counterstreaming of the cold electron beam and the ion beam excite ion acoustic waves with a given Doppler-shifted real frequency. However, the effect of the bean-shaped ion velocity distributions reduces the growth rates of ion acoustic instability. The simulation results also show that the slowing down of the ion bean is larger at the larger perpendicular velocity. The wave spectra of the electric fields at some points of the simulations show turbulence generated by growing waves.

  17. Use of cone beam computed tomography in implant dentistry: current concepts, indications and limitations for clinical practice and research.

    PubMed

    Bornstein, Michael M; Horner, Keith; Jacobs, Reinhilde

    2017-02-01

    Diagnostic radiology is an essential component of treatment planning in the field of implant dentistry. This narrative review will present current concepts for the use of cone beam computed tomography imaging, before and after implant placement, in daily clinical practice and research. Guidelines for the selection of three-dimensional imaging will be discussed, and limitations will be highlighted. Current concepts of radiation dose optimization, including novel imaging modalities using low-dose protocols, will be presented. For preoperative cross-sectional imaging, data are still not available which demonstrate that cone beam computed tomography results in fewer intraoperative complications such as nerve damage or bleeding incidents, or that implants inserted using preoperative cone beam computed tomography data sets for planning purposes will exhibit higher survival or success rates. The use of cone beam computed tomography following the insertion of dental implants should be restricted to specific postoperative complications, such as damage of neurovascular structures or postoperative infections in relation to the maxillary sinus. Regarding peri-implantitis, the diagnosis and severity of the disease should be evaluated primarily based on clinical parameters and on radiological findings based on periapical radiographs (two dimensional). The use of cone beam computed tomography scans in clinical research might not yield any evident beneficial effect for the patient included. As many of the cone beam computed tomography scans performed for research have no direct therapeutic consequence, dose optimization measures should be implemented by using appropriate exposure parameters and by reducing the field of view to the actual region of interest.

  18. Nano-Ampere Stimulation Window for Cultured Neurons on Micro-Electrode Arrays

    DTIC Science & Technology

    2001-10-25

    the electrical potential and σ the conductivity of the NANO -AMPÈRE STIMULATION WINDOW FOR CULTURED NEURONS ON MICRO -ELECTRODE ARRAYS J.R. Buitenweg1... Nano -Ampere Stimulatin Window for Cultured Neurons on Micro -Electrode Arrays Contract Number Grant Number Program Element Number Author(s) Project...membrane, using a nano -ampère current through the extracellular electrode. Also, a stimulation window is observed. These findings can be explained by a

  19. Beam Diagnostics for FACET

    SciTech Connect

    Li, S.Z.; Hogan, M.J.; /SLAC

    2011-08-19

    FACET, the Facility for Advanced Accelerator and Experimental Tests, is a new facility being constructed in sector 20 of the SLAC linac primarily to study beam driven plasma wakefield acceleration beginning in summer 2011. The nominal FACET parameters are 23GeV, 3nC electron bunches compressed to about 20 {micro}m long and focussed to about 10 {micro}m wide. Characterization of the beam-plasma interaction requires complete knowledge of the incoming beam parameters on a pulse-to-pulse basis. FACET diagnostics include Beam Position Monitors, Toroidal current monitors, X-ray and Cerenkov based energy spectrometers, optical transition radiation (OTR) profile monitors and coherent transition radiation (CTR) bunch length measurement systems. The compliment of beam diagnostics and their expected performance are reviewed. Beam diagnostic measurements not only provide valuable insights to the running and tuning of the accelerator but also are crucial for the PWFA experiments in particular. Beam diagnostic devices are being set up at FACET and will be ready for beam commissioning in summer 2011.

  20. Design and characterization of a multi-beam micro-CT scanner based on carbon nanotube field emission x-ray technology

    NASA Astrophysics Data System (ADS)

    Peng, Rui

    In this dissertation, I will present the results for my Ph.D. research for the past five years. My project mainly focuses on advanced imaging applications with a multi-beam x-ray source array based on carbon nanotube field emission technology. In the past few years, research in carbon nanotubes gradually changed from the raw material science to its application. Field emission x-ray application is one of the hottest research areas for carbon nanotube. Compared to traditional thermionic x-ray sources, the carbon nanotube field emission x-ray source has some natural advantages over traditional thermionic x-ray sources such as instantaneous x-ray generation, programmability and miniaturization. For the past few years, the research and development of carbon nanotube field emission x-ray has shifted from single x-ray beam applications to spatially distributed multi-beam x-ray sources. Previously in Zhou group, we have already built a gated micro-CT system with single beam micro-focus x-ray tube for higher spatial and temporal resolution as required in live animal imaging and a multi-beam tomosynthesis system targeting for faster and more stable breast imaging. Now my project mainly focused on the design, characterization and optimization of a multi-beam micro-CT imaging system. With the increase of gantry rotation speed approaching the mechanical limit, it is getting more and more difficult to further speed up the CT scanning. My new system promises a potential solution for the problem, and it serves as a great test platform for truly stationary micro-CT geometry. The potential capabilities it showed during the characterization and imaging measurements was promising. The dissertation is composed of five chapters. In Chapter 1, I will generally review the physics principles of x-ray generation and interaction with matter. Then the discovery of carbon nanotube and its great potential to serve as an excellent field emission electron source will be introduced in the second

  1. Aging characteristics of blue InGaN micro-light emitting diodes at an extremely high current density of 3.5 kA cm-2

    NASA Astrophysics Data System (ADS)

    Tian, Pengfei; Althumali, Ahmad; Gu, Erdan; Watson, Ian M.; Dawson, Martin D.; Liu, Ran

    2016-04-01

    The aging characteristics of blue InGaN micro-light emitting diodes (micro-LEDs) with different sizes have been studied at an extremely high current density 3.5 kA cm-2 for emerging micro-LED applications including visible light communication (VLC), micro-LED pumped organic lasers and optogenetics. The light output power of micro-LEDs first increases and then decreases due to the competition of Mg activation in p-GaN layer and defect generation in the active region. The smaller micro-LEDs show less light output power degradation compared with larger micro-LEDs, which is attributed to the lower junction temperature of smaller micro-LEDs. It is found that the high current density without additional junction temperature cannot induce significant micro-LED degradation at room temperature but the combination of the high current density and high junction temperature leads to strong degradation. Furthermore, the cluster LEDs, composed of a micro-LED array, have been developed with both high light output power and less light output degradation for micro-LED applications in solid state lighting and VLC.

  2. Three-dimensional focus of attention for iterative cone-beam micro-CT reconstruction

    NASA Astrophysics Data System (ADS)

    Benson, T. M.; Gregor, J.

    2006-09-01

    Three-dimensional iterative reconstruction of high-resolution, circular orbit cone-beam x-ray CT data is often considered impractical due to the demand for vast amounts of computer cycles and associated memory. In this paper, we show that the computational burden can be reduced by limiting the reconstruction to a small, well-defined portion of the image volume. We first discuss using the support region defined by the set of voxels covered by all of the projection views. We then present a data-driven preprocessing technique called focus of attention that heuristically separates both image and projection data into object and background before reconstruction, thereby further reducing the reconstruction region of interest. We present experimental results for both methods based on mouse data and a parallelized implementation of the SIRT algorithm. The computational savings associated with the support region are substantial. However, the results for focus of attention are even more impressive in that only about one quarter of the computer cycles and memory are needed compared with reconstruction of the entire image volume. The image quality is not compromised by either method.

  3. Micro-metric electronic patterning of a topological band structure using a photon beam

    NASA Astrophysics Data System (ADS)

    Golden, Mark; Frantzeskakis, Emmanouil; de Jong, Nick; Huang, Yingkai; Wu, Dong; Pan, Yu; de Visser, Anne; van Heumen, Erik; van Bay, Tran; Zwartsenberg, Berend; Pronk, Pieter; Varier Ramankutty, Shyama; Tytarenko, Alona; Xu, Nan; Plumb, Nick; Shi, Ming; Radovic, Milan; Varkhalov, Andrei

    2015-03-01

    The only states crossing EF in ideal, 3D TIs are topological surface states. Single crystals of Bi2Se3andBi2Te3 are too defective to exhibit bulk-insulating behaviour, and ARPES shows topologically trivial 2DEGs at EF in the surface region due to downward band bending. Ternary & quaternary alloys of Bi /Te /Se /Sb hold promise for obtaining bulk-insulating crystals. Here we report ARPES data from quaternary, bulk-insulating, Bi-based TIs. Shortly after cleavage in UHV, downward band bending pulls the bulk conduction band below EF, once again frustrating the ``topological only'' ambition for the Fermi surface. However, there is light at the end of the tunnel: we show that a super-band-gap photon beam generates a surface photovoltage sufficient to flatten the bands, thereby recovering the ideal, ``topological only'' situation. In our bulk-insulating quaternary TIs, this effect is local in nature, and permits the writing of arbitrary, micron-sized patterns in the topological energy landscape at the surface. Support from FOM, NWO and the EU is gratefully acknowledged.

  4. Cone-beam micro-CT system based on LabVIEW software.

    PubMed

    Ionita, Ciprian N; Hoffmann, Keneth R; Bednarek, Daniel R; Chityala, Ravishankar; Rudin, Stephen

    2008-09-01

    Construction of a cone-beam computed tomography (CBCT) system for laboratory research usually requires integration of different software and hardware components. As a result, building and operating such a complex system require the expertise of researchers with significantly different backgrounds. Additionally, writing flexible code to control the hardware components of a CBCT system combined with designing a friendly graphical user interface (GUI) can be cumbersome and time consuming. An intuitive and flexible program structure, as well as the program GUI for CBCT acquisition, is presented in this note. The program was developed in National Instrument's Laboratory Virtual Instrumentation Engineering Workbench (LabVIEW) graphical language and is designed to control a custom-built CBCT system but has been also used in a standard angiographic suite. The hardware components are commercially available to researchers and are in general provided with software drivers which are LabVIEW compatible. The program structure was designed as a sequential chain. Each step in the chain takes care of one or two hardware commands at a time; the execution of the sequence can be modified according to the CBCT system design. We have scanned and reconstructed over 200 specimens using this interface and present three examples which cover different areas of interest encountered in laboratory research. The resulting 3D data are rendered using a commercial workstation. The program described in this paper is available for use or improvement by other researchers.

  5. Effects of non-ideal boundary conditions on the vibrations of a slightly curved micro beam

    NASA Astrophysics Data System (ADS)

    Sarı, Gözde; Pakdemirli, Mehmet

    2012-11-01

    Response of a slightly curved resonant microbeam having non-ideal boundary conditions is investigated. Non-ideal boundary conditions are formulated using perturbation theory. These non-ideal conditions allow for small deflection at the right end of the microbeam. The curvature is taken as a sinusoidal function of the spatial variable. The initial displacement is due to the geometry of the microbeam itself. They are produced intentionally to be curved or made curved by buckling straight beams through compressive axial loads. The model accounts for mid-plane stretching, an applied axial load and an AC harmonic force. The ends of the curved microbeam are on immovable simple supports. Immovable end conditions introduce integral type nonlinearity. The integro-differential equations of motion are solved analytically by means of direct application of the method of multiple scales (a perturbation method). The amplitude and phase modulation equations are derived for the case of primary resonances. The effect of curvature on the vibrations of the microbeam is examined. It is found that the effect of curvature is of softening type. The frequencies and mode shapes obtained are compared with the ideal boundary conditions case and the differences between them are contrasted on frequency response curves.

  6. Micro-metric electronic patterning of a topological band structure using a photon beam

    PubMed Central

    Frantzeskakis, E.; De Jong, N.; Zwartsenberg, B.; Huang, Y. K.; Bay, T. V.; Pronk, P.; Van Heumen, E.; Wu, D.; Pan, Y.; Radovic, M.; Plumb, N. C.; Xu, N.; Shi, M.; De Visser, A.; Golden, M. S.

    2015-01-01

    In an ideal 3D topological insulator (TI), the bulk is insulating and the surface conducting due to the existence of metallic states that are localized on the surface; these are the topological surface states. Quaternary Bi-based compounds of Bi2−xSbxTe3−ySey with finely-tuned bulk stoichiometries are good candidates for realizing ideal 3D TI behavior due to their bulk insulating character. However, despite its insulating bulk in transport experiments, the surface region of Bi2−xSbxTe3−ySey crystals cleaved in ultrahigh vacuum also exhibits occupied states originating from the bulk conduction band. This is due to adsorbate-induced downward band-bending, a phenomenon known from other Bi-based 3D TIs. Here we show, using angle-resolved photoemission, how an EUV light beam of moderate flux can be used to exclude these topologically trivial states from the Fermi level of Bi1.46Sb0.54Te1.7Se1.3 single crystals, thereby re-establishing the purely topological character of the low lying electronic states of the system. We furthermore prove that this process is highly local in nature in this bulk-insulating TI, and are thus able to imprint structures in the spatial energy landscape at the surface. We illustrate this by ‘writing’ micron-sized letters in the Dirac point energy of the system. PMID:26543011

  7. Revisiting cAMP signaling in the carotid body

    PubMed Central

    Nunes, Ana R.; Holmes, Andrew P.; Conde, Sílvia V.; Gauda, Estelle B.; Monteiro, Emília C.

    2014-01-01

    Chronic carotid body (CB) activation is now recognized as being essential in the development of hypertension and promoting insulin resistance; thus, it is imperative to characterize the chemotransduction mechanisms of this organ in order to modulate its activity and improve patient outcomes. For several years, and although controversial, cyclic adenosine monophosphate (cAMP) was considered an important player in initiating the activation of the CB. However, its relevance was partially displaced in the 90s by the emerging role of the mitochondria and molecules such as AMP-activated protein kinase and O2-sensitive K+ channels. Neurotransmitters/neuromodulators binding to metabotropic receptors are essential to chemotransmission in the CB, and cAMP is central to this process. cAMP also contributes to raise intracellular Ca2+ levels, and is intimately related to the cellular energetic status (AMP/ATP ratio). Furthermore, cAMP signaling is a target of multiple current pharmacological agents used in clinical practice. This review (1) provides an outline on the classical view of the cAMP-signaling pathway in the CB that originally supported its role in the O2/CO2 sensing mechanism, (2) presents recent evidence on CB cAMP neuromodulation and (3) discusses how CB activity is affected by current clinical therapies that modify cAMP-signaling, namely dopaminergic drugs, caffeine (modulation of A2A/A2B receptors) and roflumilast (PDE4 inhibitors). cAMP is key to any process that involves metabotropic receptors and the intracellular pathways involved in CB disease states are likely to involve this classical second messenger. Research examining the potential modification of cAMP levels and/or interactions with molecules associated with CB hyperactivity is currently in its beginning and this review will open doors for future explorations. PMID:25389406

  8. Dislocation-based plasticity model and micro-beam Laue diffraction analysis of polycrystalline Ni foil: A forward prediction

    NASA Astrophysics Data System (ADS)

    Song, Xu; Hofmann, Felix; Korsunsky, Alexander M.

    2010-10-01

    A physically-based, rate and length-scale dependent strain gradient crystal plasticity framework was employed to simulate the polycrystalline plastic deformation at the microscopic level in a large-grained, commercially pure Ni sample. The latter was characterised in terms of the grain morphology and orientation (in the bulk) by micro-beam Laue diffraction experiments carried out on beamline B16 at Diamond Light Source. The corresponding finite element model was developed using a grain-based mesh with the specific grain orientation assignment appropriate for the sample considered. Sample stretching to 2% plastic strain was simulated, and a post-processor was developed to extract the information about the local lattice misorientation (curvature), enabling forward-prediction of the Laue diffraction patterns. The 'streaking' phenomenon of the Laue spots (anisotropic broadening of two-dimensional (2D) diffraction peaks observed on the 2D detector) was correctly captured by the simulation, as constructed by direct superposition of reflections from different integration points within the diffraction gauge volume. Good agreement was found between the images collected from experiments and simulation patterns at various positions in the sample.

  9. Characterisation of edgeless technologies for pixellated and strip silicon detectors with a micro-focused X-ray beam

    NASA Astrophysics Data System (ADS)

    Bates, R.; Blue, A.; Christophersen, M.; Eklund, L.; Ely, S.; Fadeyev, V.; Gimenez, E.; Kachkanov, V.; Kalliopuska, J.; Macchiolo, A.; Maneuski, D.; Phlips, B. F.; Sadrozinski, H. F.-W.; Stewart, G.; Tartoni, N.; Zain, R. M.

    2013-01-01

    Reduced edge or ``edgeless'' detector design offers seamless tileability of sensors for a wide range of applications from particle physics to synchrotron and free election laser (FEL) facilities and medical imaging. Combined with through-silicon-via (TSV) technology, this would allow reduced material trackers for particle physics and an increase in the active area for synchrotron and FEL pixel detector systems. In order to quantify the performance of different edgeless fabrication methods, 2 edgeless detectors were characterized at the Diamond Light Source using an 11 μm FWHM 15 keV micro-focused X-ray beam. The devices under test were: a 150 μm thick silicon active edge pixel sensor fabricated at VTT and bump-bonded to a Medipix2 ROIC; and a 300 μm thick silicon strip sensor fabricated at CIS with edge reduction performed by SCIPP and the NRL and wire bonded to an ALiBaVa readout system. Sub-pixel resolution of the 55 μm active edge pixels was achieved. Further scans showed no drop in charge collection recorded between the centre and edge pixels, with a maximum deviation of 5% in charge collection between scanned edge pixels. Scans across the cleaved and standard guard ring edges of the strip detector also show no reduction in charge collection. These results indicate techniques such as the scribe, cleave and passivate (SCP) and active edge processes offer real potential for reduced edge, tiled sensors for imaging detection applications.

  10. Analysis of A.W glass-ceramic surface by micro-beam x-ray diffraction.

    PubMed

    Kitsugi, T; Yamamuro, T; Kokubo, T

    1990-02-01

    The purpose of this study is to examine the formation of hydroxyapatite on the surface of glass-ceramics (chemical composition: SiO2, 34.2; P2O5, 16.3; CaO, 44.9; MgO, 4.6; CaF2, 0.5 in weight ratio). Two experiments were performed. In the first experiment, plates (2 x 25 x 25 mm) of glass-ceramics containing apatite-wollastonite (designated A.W-GC) were used. In the second experiment, plates (15 x 10 x 2 mm) of A.W-GC and its parent glass (designated G) were used. In each experiment, two paired specimens of identical material, one tied with silk thread, the other not tied, were implanted subcutaneously into rats. In both experiments, bonding to each other of both tied and untied specimens was observed one month after implantation. A pattern resembling hydroxyapatite was identified on the detached surface of the bonded A.W-GC by micro-beam x-ray diffraction. The weak crystalline pattern was also observed on the detached surface of bonded G samples. Analysis of the interface by SEM-EPMA showed that a calcium-phosphorus rich layer formed between the two bonded surfaces in both experiments. It is suggested that the bonding between the two materials was formed by the calcium-phosphorus rich layer, and that the calcium-phosphorus rich layer is virtually identical to hydroxyapatite.

  11. The CMS fast beams condition monitor back-end electronics based on MicroTCA technology: status and development

    NASA Astrophysics Data System (ADS)

    Zagozdzinska, Agnieszka A.; Dabrowski, Anne E.; Pozniak, Krzysztof T.

    2015-09-01

    The Fast Beams Condition Monitor (BCM1F), upgraded for LHC Run II, is used to measure the online luminosity and machine induced background for the CMS experiment. The detector consists of 24 single-crystal CVD diamond sensors that are read out with a custom fast front-end chip fabricated in 130 nm CMOS technology. Since the signals from the sensors are used for real time monitoring of the LHC conditions they are processed by dedicated back-end electronics to measure separately rates corresponding to LHC collision products, machine induced background and residual activation exploiting different arrival times. The system is built in MicroTCA technology and uses high speed analog-to-digital converters. In operational modes of high rates, consecutive events, spaced in time by less than 12.5 ns, may cause partially overlapping events. Hence, novel signal processing techniques are deployed to resolve overlapping peaks. The high accuracy qualification of the signals is crucial to determine the luminosity and the machine induced background rates for the CMS experiment and the LHC.

  12. Detection of sub-ppm traces of aqueous heavy-metal ions using micro-electro-mechanical beam resonators

    NASA Astrophysics Data System (ADS)

    Rahafrooz, Amir; Pourkamali, Siavash

    2009-11-01

    Capacitive silicon micro-mechanical resonators have been utilized in this work as ultra-sensitive mass sensors for the detection of trace amounts of copper ions in water samples. The approach is based on the reduction of aqueous metal ions by the silicon in a resonant structure and consequently deposition of a very thin metal layer on the resonator surface changing its resonant frequency. Measurements demonstrate successful detection of sub-ppm concentrations of copper(II) ions in water. Relatively large frequency shifts (hundreds of ppm) have been measured for resonators exposed to copper concentrations as low as 4 µM (0.26 ppm). An analytical model for the resonant frequency of the resulting complex beams has been derived and used to calculate the thickness of the deposited copper layer based on the measured frequency shifts. The model shows that the measured frequency shifts correspond to only a few atomic layers of copper (as thin as ~7 Å) deposited on the resonator surfaces. This corresponds to a mass sensitivity of more than 4000 Hz µg-1 cm-2 which is much larger than the highest mass sensitivities measured for quartz crystal microbalances.

  13. Nano- and Micro-Structured UHMWPE Composites Filled With Hydroxyapatite Irradiated by Nitrogen Ion Beams for Bio-Medical Applications

    NASA Astrophysics Data System (ADS)

    Panin, S. V.; Kornienko, L. A.; Chaikina, M. V.; Sergeev, V. P.; Ivanova, L. R.; Shilko, S. V.

    2014-02-01

    The effect of filling the ultra-high-molecular-weight polyethylene (UHMWPE) with nano- and microparticles of hydroxyapatite (HA) on its structure and tribotechnical properties is investigated, aiming at application of the modified UHMWPE in endoprosthetics. An introduction of 0.1-0.5 wt% HA nanoparticles into UHMWPE is shown to result in a threefold increase in its wear resistance. A similar effect is observed in the case where 20 wt% of HA microparticles is used. Treatment of the surface of nano- and microcomposites with a nitrogen ion beam increases the wear resistance by an additional 10-30%. A combined treatment of UHMWPE powder and fillers in a planetary ball mill leads to a uniform distribution of the latter in the polymer matrix and, consequently, to the formation of a more ordered permolecular structure. In the irradiated UHMWPE micro- and nanocomposites reinforced with HA, the tribotechnical properties are shown to improve due to the formation of new chemical bonds (primarily via cross-linking) and ordered permolecular structure.

  14. cAMP and Mitochondria

    PubMed Central

    Valsecchi, Federica; Ramos-Espiritu, Lavoisier S.; Buck, Jochen; Levin, Lonny R.

    2013-01-01

    Phosphorylation of mitochondrial proteins has emerged as a major regulatory mechanism for metabolic adaptation. cAMP signaling and PKA phosphorylation of mitochondrial proteins have just started to be investigated, and the presence of cAMP-generating enzymes and PKA inside mitochondria is still controversial. Here, we discuss the role of cAMP in regulating mitochondrial bioenergetics through protein phosphorylation and the evidence for soluble adenylyl cyclase as the source of cAMP inside mitochondria. PMID:23636265

  15. Optimization of a ribbon diode with magnetic insulation for increasing the current density in a high-current relativistic electron beam

    NASA Astrophysics Data System (ADS)

    Astrelin, V. T.; Arzhannikov, A. V.; Burdakov, A. V.; Sinitskii, S. L.; Stepanov, V. D.

    2009-05-01

    The geometry of the ribbon diode of the U-2 accelerator is optimized to increase both the current density and the total current of the relativistic electron beam for its subsequent injection into the plasma of a multimirror GOL-3 trap. Beam simulation in the diode was performed using the POISSON-2 applied software modified on the basis of the results obtained using the theory of a planar diode in an inclined magnetic field. As a result of the optimization, the diode geometry and the magnetic field configuration were found that should provide a factor of 1.5-2 increase in the current density in experiments with a small angular divergence of electron velocities.

  16. Pressure and current balance conditions during electron beam injections from spacecraft

    NASA Technical Reports Server (NTRS)

    Hwang, K. S.; Singh, Nagendra

    1990-01-01

    Electrostatic charging level of a conducting surface in response to injections of electron beams into space plasma is investigated by means of one-dimensional Vlasov code. Injections of Maxwellian beams into a vacuum shows that the surface can charge up to an electric potential phi sub s greater than W sub b, where W sub b is the average electron beam energy. Since Maxwellian beams have extended trails with electrons having energies greater than W sub b, it is difficult to quantify the charging level in terms of the energies of the injected electrons. In order to quantitatively understand the charging in excess of W sub b, simulations were carried out for water-bag types of beam with velocity distribution functions described by f(V) = A for V sub min approx. less than V approx. less than V sub max and f(V) = O otherwise, where A is a constant making the normalized beam density unity. It is found that V sub max does not directly determine the charging level. The pressure distribution in the electron sheath determines the electric field distribution near the surface. The electric field in turn determines the electrostatic potential of the vehicle. The pressure distribution is determined by the beam parameters such as the average beam velocity and the velocity spread of the beam.

  17. Box 13: Silicon Micro/Nano-Fabrication Using Proton Beam Writing and Electrochemical Etching

    NASA Astrophysics Data System (ADS)

    Blackwood, Daniel J.; Teo, Ee Jin

    The fabrication of 3D structures in silicon is at the heart of many state-of-the-art technologies. Conventional etching technologies require multiple processing steps to fabricate free-standing multilevel structures [1, 2]. The two main wet chemistry procedures are chemical etching in KOH, which is unfortunately isotropic with very slow etching of <111> planes, and electrochemical etching in HF [3]. The electrochemical etching rate is proportional to the flux of holes to the silicon/electrolyte interface, i.e., the applied current density, so it is easy to control and anisotropic. Etching Si in HF at low current densities produces porous silicon, which can be selectively removed by KOH. The low cost and easy implementation of electrochemical etching has made it an attractive alternative to dry etching.

  18. Overview of the current spectroscopy effort on the Livermore electron beam ion traps

    SciTech Connect

    Beiersdorfer, P.; Lopez-Urrutia, J.C.; Brown, G.

    1995-06-29

    An overview is given of the current spectroscopic effort on the Livermore electron beam ion trap facilities. The effort focuses on four aspects: spectral line position, line intensity, temporal evolution, and line shape. Examples of line position measurements include studies of the K-shell transitions in heliumlike Kr{sup 34+} and the 2s-2p intrashell transitions in lithiumlike Th{sup 87+} and U{sup 89+}, which provide benchmark values for testing the theory of relativistic and quantum electrodynamical contributions in high-Z ions. Examples of line intensity measurements are provided by measurements of the electron-impact excitation and dielectronic recombination cross sections of heliumlike transition-metal ions Ti{sup 20+} through CO{sup 25+}. A discussion of radiative lifetime measurements of metastable levels in heliumlike ions is given to illustrate the time-resolved spectroscopy techniques in the microsecond range. The authors also present a measurement of the spectral lineshape that illustrates the very low ion temperatures that can be achieved in an EBIT.

  19. Experimental Estimating Deflection of a Simple Beam Bridge Model Using Grating Eddy Current Sensors

    PubMed Central

    Lü, Chunfeng; Liu, Weiwen; Zhang, Yongjie; Zhao, Hui

    2012-01-01

    A novel three-point method using a grating eddy current absolute position sensor (GECS) for bridge deflection estimation is proposed in this paper. Real spatial positions of the measuring points along the span axis are directly used as relative reference points of each other rather than using any other auxiliary static reference points for measuring devices in a conventional method. Every three adjacent measuring points are defined as a measuring unit and a straight connecting bar with a GECS fixed on the center section of it links the two endpoints. In each measuring unit, the displacement of the mid-measuring point relative to the connecting bar measured by the GECS is defined as the relative deflection. Absolute deflections of each measuring point can be calculated from the relative deflections of all the measuring units directly without any correcting approaches. Principles of the three-point method and displacement measurement of the GECS are introduced in detail. Both static and dynamic experiments have been carried out on a simple beam bridge model, which demonstrate that the three-point deflection estimation method using the GECS is effective and offers a reliable way for bridge deflection estimation, especially for long-term monitoring. PMID:23112583

  20. Radiation response of multi-quantum well solar cells: Electron-beam-induced current analysis

    SciTech Connect

    Maximenko, S. I. Scheiman, D. A.; Jenkins, P. P.; Walters, R. J.; Lumb, M. P.; Hoheisel, R.; Gonzalez, M.; Messenger, S. R.; Tibbits, T. N. D.; Imaizumi, M.; Ohshima, T.; Sato, S. I.

    2015-12-28

    Solar cells utilizing multi-quantum well (MQW) structures are considered promising candidate materials for space applications. An open question is how well these structures can resist the impact of particle irradiation. The aim of this work is to provide feedback about the radiation response of In{sub 0.01}Ga{sub 0.99}As solar cells grown on Ge with MQWs incorporated within the i-region of the device. In particular, the local electronic transport properties of the MQW i-regions of solar cells subjected to electron and proton irradiation were evaluated experimentally using the electron beam induced current (EBIC) technique. The change in carrier collection distribution across the MQW i-region was analyzed using a 2D EBIC diffusion model in conjunction with numerical modeling of the electrical field distribution. Both experimental and simulated findings show carrier removal and type conversion from n- to p-type in MQW i-region at a displacement damage dose as low as ∼6.06–9.88 × 10{sup 9} MeV/g. This leads to a redistribution of the electric field and significant degradation in charge carrier collection.

  1. Radiation response of multi-quantum well solar cells: Electron-beam-induced current analysis

    NASA Astrophysics Data System (ADS)

    Maximenko, S. I.; Lumb, M. P.; Hoheisel, R.; Gonzalez, M.; Scheiman, D. A.; Messenger, S. R.; Tibbits, T. N. D.; Imaizumi, M.; Ohshima, T.; Sato, S. I.; Jenkins, P. P.; Walters, R. J.

    2015-12-01

    Solar cells utilizing multi-quantum well (MQW) structures are considered promising candidate materials for space applications. An open question is how well these structures can resist the impact of particle irradiation. The aim of this work is to provide feedback about the radiation response of In0.01Ga0.99As solar cells grown on Ge with MQWs incorporated within the i-region of the device. In particular, the local electronic transport properties of the MQW i-regions of solar cells subjected to electron and proton irradiation were evaluated experimentally using the electron beam induced current (EBIC) technique. The change in carrier collection distribution across the MQW i-region was analyzed using a 2D EBIC diffusion model in conjunction with numerical modeling of the electrical field distribution. Both experimental and simulated findings show carrier removal and type conversion from n- to p-type in MQW i-region at a displacement damage dose as low as ˜6.06-9.88 × 109 MeV/g. This leads to a redistribution of the electric field and significant degradation in charge carrier collection.

  2. Transportation of high-current ion and electron beams in the accelerator drift gap in the presence of an additional electron background

    SciTech Connect

    Karas’, V. I. Kornilov, E. A.; Manuilenko, O. V.; Tarakanov, V. P.; Fedorovskaya, O. V.

    2015-12-15

    The dynamics of a high-current ion beam propagating in the drift gap of a linear induction accelerator with collective focusing is studied using 3D numerical simulations in the framework of the full system of the Vlasov–Maxwell equations (code KARAT). The ion beam is neutralized by a comoving electron beam in the current density and, partially, in space charge, since the velocities of electrons and ions differ substantially. The dynamics of the high-current ion beam is investigated for different versions of additional neutralization of its space charge. It is established that, for a given configuration of the magnetic field and in the presence of a specially programmed injection of additional electrons from the boundary opposite to the ion injection boundary, the angular divergence of the ion beam almost vanishes, whereas the current of the ion beam at the exit from the accelerator drift gap changes insignificantly and the beam remains almost monoenergetic.

  3. Transportation of high-current ion and electron beams in the accelerator drift gap in the presence of an additional electron background

    NASA Astrophysics Data System (ADS)

    Karas', V. I.; Kornilov, E. A.; Manuilenko, O. V.; Tarakanov, V. P.; Fedorovskaya, O. V.

    2015-12-01

    The dynamics of a high-current ion beam propagating in the drift gap of a linear induction accelerator with collective focusing is studied using 3D numerical simulations in the framework of the full system of the Vlasov-Maxwell equations (code KARAT). The ion beam is neutralized by a comoving electron beam in the current density and, partially, in space charge, since the velocities of electrons and ions differ substantially. The dynamics of the high-current ion beam is investigated for different versions of additional neutralization of its space charge. It is established that, for a given configuration of the magnetic field and in the presence of a specially programmed injection of additional electrons from the boundary opposite to the ion injection boundary, the angular divergence of the ion beam almost vanishes, whereas the current of the ion beam at the exit from the accelerator drift gap changes insignificantly and the beam remains almost monoenergetic.

  4. SU-E-T-198: Comparison Between a PTW MicroDiamond Dosimeter and a Markus Chamber in a 62 MeV/n Carbon Ion Beam

    SciTech Connect

    Rossomme, S; Hopfgartner, J; Delor, A; Vynckier, S; Palmans, H

    2015-06-15

    Purpose: To investigate the linear energy transfer (LET) dependence of a PTW Freiburg microDiamond dosimeter, we compared its response to the response of a plane-parallel Markus chamber in a 62 MeV/n mono-energetic carbon ion beam. Methods: The response of both detectors has been studied as a function of depth in graphite by adding or removing graphite plates in front of the detectors. To account for fluctuations of the beam, we used two setups with different monitor chambers. The depth of the effective point of measurement of both detectors has been converted into a graphite equivalent depth using ICRU Report 73 data. As recommended by IAEA TRS-398, the response of the Markus chamber has been corrected for temperature, pressure, polarity effects and ion recombination. The latter required an additional experiment; to quantify the effect of volume recombination and initial recombination, measurements have been performed at different voltages and different dose rates. Results: As expected, the dominant process leading to ion recombination for carbon ion beam is the initial recombination. At the entrance, the ion recombination correction equals 1.1% and the value is approximately constant in the plateau region. Due to the increase of the LET in the Bragg peak region, we observe a strong increase of the ion recombination correction, up to 6.1% at the distal edge. Comparison between the microDiamond response and the Markus chamber response shows good agreement in the plateau region. However, we observe a 13.6% under response of the microDiamond in the Bragg peak. Conclusion: Increasing between 1% and 6%, the depth dependent ion recombination correction has to be applied to the Markus response. The comparison between the microDiamond and the Markus chamber indicates that there is an under-response of the microDiamond in the vicinity of the Bragg peak due to the increased LET.

  5. Clinical utility of dental cone-beam computed tomography: current perspectives

    PubMed Central

    Jaju, Prashant P; Jaju, Sushma P

    2014-01-01

    Panoramic radiography and computed tomography were the pillars of maxillofacial diagnosis. With the advent of cone-beam computed tomography, dental practice has seen a paradigm shift. This review article highlights the potential applications of cone-beam computed tomography in the fields of dental implantology and forensic dentistry, and its limitations in maxillofacial diagnosis. PMID:24729729

  6. Beam charge and current neutralization of high-charge-state heavy ions

    SciTech Connect

    Logan, B.G.; Callahan, D.A.

    1997-10-29

    High-charge-state heavy-ions may reduce the accelerator voltage and cost of heavy-ion inertial fusion drivers, if ways can be found to neutralize the space charge of the highly charged beam ions as they are focused to a target in a fusion chamber. Using 2-D Particle-In- Cell simulations, we have evaluated the effectiveness of two different methods of beam neutralization: (1) by redistribution of beam charge in a larger diameter, preformed plasma in the chamber, and (2), by introducing a cold-electron-emitting source within the beam channel at the beam entrance into the chamber. We find the latter method to be much more effective for high-charge-state ions.

  7. The 100,000 amp dc power supply for a staged hadron collider superferric magnet

    SciTech Connect

    Hays, Steven L.; Claypool, Bradley; Foster, G.William; /Fermilab

    2005-09-01

    A 1.5 volt 100,000 amp DC switcher power supply was developed for testing a superferric magnet string at FNAL. This supply was used during testing as both the ramping supply and holding supply powering a single magnet load with a total load resistance of 0.7{micro} Ohms. The supply consists of ten paralleled switcher cells, powered by a 400 volt/600 Amp DC power supply. Each cell consists of an IGBT H-bridge driving a step-down transformer at a switching frequency of 2 kHz. The transformer has an effective turns ratio of 224:1. The secondary consists of 32 parallel single-turn full wave rectifier windings. The rectification is done with 64 Shottky diodes. Each cell is rated at 1.5 volts/10,000 amps. During this test each cell was operated as a constant power source without load current or field feedback. This paper will describe the design of the switcher cell and control system used during testing. We will also describe the next level of improvements to the current feedback system to improve the ramp control.

  8. An improved pulse-line accelerator-driven, intense current-density, and high-brightness pseudospark electron beam

    SciTech Connect

    Zhu, J.; Wang, Z.; Zhang, L.; Wang, M.

    1996-02-01

    A high-voltage (200 kV), high current-density, low-emittance (23 {pi}{center_dot}mm mrd), high-brightness (8 {times} 10{sup 10} A/(mrd){sup 2}) electron beam was generated in a pseudospark chamber filled with 15 Pa nitrogen and driven by a modified pulse line accelerator. The beam ejected with {le}1-mm diameter, 2.2-kA beam current, 400-ns pulse length, and about 20 cm propagation distance. Exposure of 10 shots on the same film produced a hole of 1.6-mm diameter at 7 cm downstream of the anode, and showed its good reproducibility. After 60 shots, it was observed that almost no destructive damage traces were left on the surfaces of the various electrodes and insulators of the pseudospark discharge chamber. It was experimentally found that the quality of the pseudospark electron beam remains very high, even at high voltages (of several hundred kilovolts), similar to low voltages, and is much better than the quality of the cold-cathode electron beams.

  9. Generation of dual pulses of the runaway electron beam current during the subnanosecond breakdown of atomic and molecular gases

    NASA Astrophysics Data System (ADS)

    Tarasenko, V. F.; Sorokin, D. A.; Lomaev, M. I.

    2016-10-01

    With a diaphragm placed behind the anode foil, dual runaway electron beams have been provided in helium, hydrogen, nitrogen, and air under a pressure of several torrs to several dozen torrs and a high-voltage pulse amplitude of about 250 kV. These beams consist of two pulses with commensurable amplitudes with a time interval between them of several dozen picoseconds to several hundred picoseconds. It has been shown that the breakdown of the interelectrode gap at pressures from several torrs to several dozen torrs may occur in different regimes and dual pulses of the electron beam current are registered when the initial current through the gap is below 1 kA. It has been found that a supershort avalanche electron beam that consists of one pulse is generated when the delay of breakdown equals several hundred picoseconds. It has been shown that, when the gas pressure reaches several hundred Torr, including atmospheric pressure, the runaway electrons are detected behind the foil after the termination of the supershort avalanche electron beam pulse.

  10. Simultaneous measurement of temperature and refractive index using focused ion beam milled Fabry-Perot cavities in optical fiber micro-tips.

    PubMed

    André, Ricardo M; Warren-Smith, Stephen C; Becker, Martin; Dellith, Jan; Rothhardt, Manfred; Zibaii, M I; Latifi, H; Marques, Manuel B; Bartelt, Hartmut; Frazão, Orlando

    2016-06-27

    Optical fiber micro-tips are promising devices for sensing applications in small volume and difficult to access locations, such as biological and biomedical settings. The tapered fiber tips are prepared by dynamic chemical etching, reducing the size from 125 μm to just a few μm. Focused ion beam milling is then used to create cavity structures on the tapered fiber tips. Two different Fabry-Perot micro-cavities have been prepared and characterized: a solid silica cavity created by milling two thin slots and a gap cavity. A third multi-cavity structure is fabricated by combining the concepts of solid silica cavity and gap cavity. This micro-tip structure is analyzed using a fast Fourier transform method to demultiplex the signals of each cavity. Simultaneous measurement of temperature and external refractive index is then demonstrated, presenting sensitivities of - 15.8 pm/K and -1316 nm/RIU, respectively.

  11. Investigations of Beam Dynamics Issues at Current and Future Hadron Accelerators

    SciTech Connect

    Ellison, James; Lau, Stephen; Heinemann, Klaus; Bizzozero, David

    2015-03-12

    Final Report Abstract for DE-FG02-99ER4110, May 15, 2011- October 15, 2014 There is a synergy between the fields of Beam Dynamics (BD) in modern particle accelerators and Applied Mathematics (AMa). We have formulated significant problems in BD and have developed and applied tools within the contexts of dynamical systems, topological methods, numerical analysis and scientific computing, probability and stochastic processes, and mathematical statistics. We summarize the three main areas of our AMa work since 2011. First, we continued our study of Vlasov-Maxwell systems. Previously, we developed a state of the art algorithm and code (VM3@A) to calculate coherent synchrotron radiation in single pass systems. In this cycle we carefully analyzed the major expense, namely the integral-over-history (IOH), and developed two approaches to speed up integration. The first strategy uses a representation of the Bessel function J0 in terms of exponentials. The second relies on “local sequences” developed recently for radiation boundary conditions, which are used to reduce computational domains. Although motivated by practicality, both strategies involve interesting and rather deep analysis and approximation theory. As an alternative to VM3@A, we are integrating Maxwell’s equations by a time-stepping method, bypass- ing the IOH, using a Discontinuous Galerkin (DG) method. DG is a generalization of Finite Element and Finite Volume methods. It is spectrally convergent, unlike the commonly used Finite Difference methods, and can handle complicated vacuum chamber geometries. We have applied this in several contexts and have obtained very nice results including an explanation of an experiment at the Canadian Light Source, where the geometry is quite complex. Second, we continued our study of spin dynamics in storage rings. There is much current and proposed activity where spin polarized beams are being used in testing the Standard Model and its modifications. Our work has focused

  12. Method of active charge and current neutralization of intense ion beams for ICF

    SciTech Connect

    Guiragossian, Z.G.T.; Orthel, J.L.; Lemons, D.S.; Thode, L.E.

    1981-01-01

    Methods of generating the beam neutralization electrons with required properties are given in the context of a Light Ion Fusion Experiment (LIFE) designed accelerator. Recently derived envelope equations for neutralized and ballistically focused intense ion beams are applied to the LIFE geometry in which 10 MeV He/sup +/ multiple beamlets coalesce and undergo 45:1 radial compression while beam pulses experience a 20:1 axial compression in the propagation range of 10 m. Both active and auto-neutralization methods are examined and found to produce initial electron temperatures consistent with the requirement of the envelope equation for both radial and axial adiabatic beam pulse compressions. The stability of neutralized beam propagation is also examined concerning the Pierce type electrostatic instability and for the case of LIFE beams it is found to have insignificant effect. A scaled experimental setup is presented which can serve to perform near term tests on the ballistically focused propagation of neutralized light ion beams.

  13. Formyl peptides and ATP stimulate Ca2+ and Na+ inward currents through non-selective cation channels via G-proteins in dibutyryl cyclic AMP-differentiated HL-60 cells. Involvement of Ca2+ and Na+ in the activation of beta-glucuronidase release and superoxide production.

    PubMed

    Krautwurst, D; Seifert, R; Hescheler, J; Schultz, G

    1992-12-15

    In human neutrophils, the chemotactic peptide N-formyl-L-methionyl-L-leucyl-L-phenylalanine (fMLP) induces increases in the intracellular free Ca2+ concentration ([Ca2+]i) with subsequent activation of beta-glucuronidase release and superoxide (O2-) production. Results from several laboratories suggest that the increase in [Ca2+]i is due to activation of non-selective cation (NSC) channels. We studied the biophysical characteristics, pharmacological modulation and functional role of NSC channels in dibutyryl cyclic AMP (Bt2cAMP)-differentiated HL-60 cells. fMLP increased [Ca2+]i by release of Ca2+ from intracellular stores and influx of Ca2+ from the extracellular space. fMLP also induced Mn2+ influx. Ca2+ and Mn2+ influxes were inhibited by 1-(beta-[3-(4-methoxyphenyl)propoxy]-4-methoxyphenethyl)-1H-imidazole hydrochloride (SK&F 96365). Under whole-cell voltage-clamp conditions, fMLP and ATP (a purinoceptor agonist) activated inward currents characterized by a linear current-voltage relationship and a reversal potential near 0 mV. NSC channels were substantially more permeable to Na+ than to Ca2+. SK&F 96365 inhibited fMLP- and ATP-stimulated currents with a half-maximal effect at about 3 microM. Pertussis toxin prevented stimulation by fMLP of NSC currents and reduced ATP-stimulated currents by about 80%. Intracellular application of the stable GDP analogue, guanosine 5'-O-[2-thio]diphosphate, completely blocked stimulation by agonists of NSC currents. In excised inside-out patches, single channel openings with an amplitude of 0.24 pA were observed in the presence of fMLP and the GTP analogue, guanosine 5'-O-[3-thio]triphosphate. The bath solution contained neither Ca2+ nor ATP. The current/voltage relationship was linear with a conductance of 4-5 pS and reversed at about 0 mV. fMLP-induced beta-glucuronidase release and O2- production were substantially reduced by replacement of extracellular CaCl2 or NaCl by ethylenebis(oxyethylenenitrilo)tetra-acetic acid and

  14. Radiation damage in single crystal CVD diamond material investigated with a high current relativistic 197Au beam

    NASA Astrophysics Data System (ADS)

    Pietraszko, J.; Galatyuk, T.; Grilj, V.; Koenig, W.; Spataro, S.; Träger, M.

    2014-11-01

    Single-crystal Chemical Vapor Deposition (ScCVD) diamond based prototype detectors have been constructed for the high intensity heavy ion experiments HADES and CBM at the future FAIR facility at GSI Darmstadt. Their properties have been studied with a high current density beam (about 2-3×106/s/mm2) of 1.25A GeV Au69+197 ions. Details of the design, the intrinsic properties of the detectors and their performance after irradiation with such a beam are reported.

  15. Preliminary results concerning the simulation of beam profiles from extracted ion current distributions for mini-STRIKE

    SciTech Connect

    Agostinetti, P. Serianni, G.; Veltri, P.; Giacomin, M.; Bonomo, F.; Schiesko, L.

    2016-02-15

    The Radio Frequency (RF) negative hydrogen ion source prototype has been chosen for the ITER neutral beam injectors due to its optimal performances and easier maintenance demonstrated at Max-Planck-Institut für Plasmaphysik, Garching in hydrogen and deuterium. One of the key information to better understand the operating behavior of the RF ion sources is the extracted negative ion current density distribution. This distribution—influenced by several factors like source geometry, particle drifts inside the source, cesium distribution, and layout of cesium ovens—is not straightforward to be evaluated. The main outcome of the present contribution is the development of a minimization method to estimate the extracted current distribution using the footprint of the beam recorded with mini-STRIKE (Short-Time Retractable Instrumented Kalorimeter). To accomplish this, a series of four computational models have been set up, where the output of a model is the input of the following one. These models compute the optics of the ion beam, evaluate the distribution of the heat deposited on the mini-STRIKE diagnostic calorimeter, and finally give an estimate of the temperature distribution on the back of mini-STRIKE. Several iterations with different extracted current profiles are necessary to give an estimate of the profile most compatible with the experimental data. A first test of the application of the method to the BAvarian Test Machine for Negative ions beam is given.

  16. Robust, easily shaped, and epoxy-free carbon-fiber-aluminum cathodes for generating high-current electron beams.

    PubMed

    Liu, Lie; Li, Limin; Wen, Jianchun; Wan, Hong

    2009-02-01

    This paper presents the construction of carbon-fiber-aluminum (CFA) cathode by squeezing casting and its applications for generating high-current electron beams to drive high-power microwave sources. The fabrication process avoided using epoxy, a volatile deteriorating the vacuum system. These cathodes had a higher hardness than conventional aluminum, facilitating machining. After surface treatment, carbon fibers became the dominator determining emission property. A multineedle CFA cathode was utilized in a triode virtual cathode oscillator (vircator), powered by a approximately 450 kV, approximately 400 ns pulse. It was found that 300-400 MW, approximately 250 ns microwave was radiated at a dominant frequency of 2.6 GHz. Further, this cathode can endure high-current-density emission without detectable degradation in performance as the pulse shot proceeded, showing the robust nature of carbon fibers as explosive emitters. Overall, this new class of cold cathodes offers a potential prospect of developing high-current electron beam sources.

  17. Comparative Dosimetric Estimates of a 25 keV Electron Micro-beam with three Monte Carlo Codes

    SciTech Connect

    Mainardi, Enrico; Donahue, Richard J.; Blakely, Eleanor A.

    2002-09-11

    The calculations presented compare the different performances of the three Monte Carlo codes PENELOPE-1999, MCNP-4C and PITS, for the evaluation of Dose profiles from a 25 keV electron micro-beam traversing individual cells. The overall model of a cell is a water cylinder equivalent for the three codes but with a different internal scoring geometry: hollow cylinders for PENELOPE and MCNP, whereas spheres are used for the PITS code. A cylindrical cell geometry with scoring volumes with the shape of hollow cylinders was initially selected for PENELOPE and MCNP because of its superior simulation of the actual shape and dimensions of a cell and for its improved computer-time efficiency if compared to spherical internal volumes. Some of the transfer points and energy transfer that constitute a radiation track may actually fall in the space between spheres, that would be outside the spherical scoring volume. This internal geometry, along with the PENELOPE algorithm, drastically reduced the computer time when using this code if comparing with event-by-event Monte Carlo codes like PITS. This preliminary work has been important to address dosimetric estimates at low electron energies. It demonstrates that codes like PENELOPE can be used for Dose evaluation, even with such small geometries and energies involved, which are far below the normal use for which the code was created. Further work (initiated in Summer 2002) is still needed however, to create a user-code for PENELOPE that allows uniform comparison of exact cell geometries, integral volumes and also microdosimetric scoring quantities, a field where track-structure codes like PITS, written for this purpose, are believed to be superior.

  18. Feasibility study of fusion plasma heating by relativistic high-current electron beams

    NASA Astrophysics Data System (ADS)

    Yakimenko, V.

    2017-03-01

    The goal of this research will be to study the feasibility of fusion plasma heating using ultra-short high intensity electron beam by dissipating the energy of excited wakes either in linear or nonlinear regimes.

  19. The edge transient-current technique (E-TCT) with high energy hadron beam

    NASA Astrophysics Data System (ADS)

    Gorišek, Andrej; Cindro, Vladimir; Kramberger, Gregor; Mandić, Igor; Mikuž, Marko; Muškinja, Miha; Zavrtanik, Marko

    2016-09-01

    We propose a novel way to investigate the properties of silicon and CVD diamond detectors for High Energy Physics experiments complementary to the already well-established E-TCT technique using laser beam. In the proposed setup the beam of high energy hadrons (MIPs) is used instead of laser beam. MIPs incident on the detector in the direction parallel to the readout electrode plane and perpendicular to the edge of the detector. Such experiment could prove very useful to study CVD diamond detectors that are almost inaccessible for the E-TCT measurements with laser due to large band-gap as well as to verify and complement the E-TCT measurements of silicon. The method proposed is being tested at CERN in a beam of 120 GeV hadrons using a reference telescope with track resolution at the DUT of few μm. The preliminary results of the measurements are presented.

  20. Influence of grid control on beam quality in laser ion source generating high-current low-charged copper ions

    SciTech Connect

    Hasegawa, J.; Yoshida, M.; Ogawa, M.; Oguri, Y.; Nakajima, M.; Horioka, K.; Kwan, J.

    2003-08-01

    We examined grid-controlled extraction for a laser ion source using a KrF laser. By using grid-controlled extraction in the over-dense regime, we found that the ion beam current waveforms were stabilized more significantly as the grid bias raised from -90 V to -280 V. The normalized emittance of 0.08 {pi}mm-mrad measured without the grid control was improved to 0.06 {pi}mm-mrad with the grid control. In contrast to this observation, the grid bias disturbed the pattern of the beam extracted in the source-limited regime. Fast extraction was carried out using a high-voltage pulse with a rise time of {approx} 100 ns. The grid control suppressed successfully the beam pedestal originating from the plasma pre-filled in the extraction gap.

  1. TSH-induced cyclic AMP production in an ovine thyroid cell line: OVNIS 5H.

    PubMed

    Fayet, G; Aouani, A; Hovsépian, S

    1986-01-06

    The TSH-induced cyclic AMP response was studied using a 3-year-old ovine thyroid cell line TSH-independent for growth: OVNIS 5H. The kinetics of cyclic AMP production was followed both in cell layers and in cell culture media, with or without phosphodiesterase inhibitor. It is noteworthy that following the first wave in cyclic AMP obtained within minutes, we observed later a sustained exponential increase in cyclic AMP during the 5 days following TSH stimulation. A bioassay of TSH was derived allowing measurement of 1 microU/ml TSH from a crude bTSH preparation.

  2. Improved measurement of neutral current coherent $\\pi^0$ production on carbon in a few-GeV neutrino beam

    SciTech Connect

    Kurimoto, Y.; Alcaraz-Aunion, J.L.; Brice, S.J.; Bugel, L.; Catala-Perez, J.; Cheng, G.; Conrad, J.M.; Djurcic, Z.; Dore, U.; Finley, D.A.; Franke, A.J.; /Columbia U. /INFN, Rome

    2010-05-01

    The SciBooNE Collaboration reports a measurement of neutral current coherent neutral pion production on carbon by a muon neutrino beam with average energy 0.8 GeV. The separation of coherent from inclusive neutral pion production has been improved by detecting recoil protons from resonant neutral pion production. We measure the ratio of the neutral current coherent neutral pion production to total charged current cross sections to be (1.16 +/- 0.24) x 10-2. The ratio of charged current coherent pion to neutral current coherent pion production is calculated to be 0.14+0.30 -0.28, using our published charged current coherent pion measurement.

  3. Modeling of neutral beam injection heating and current drive during the ramp-up phase in KSTAR

    NASA Astrophysics Data System (ADS)

    Terzolo, L.

    2014-06-01

    For flexible control of the plasma pressure and the current profiles, which are essential for a high performance plasma with long pulse operation, KSTAR is going to implement several heating and current systems, which include Neutral Beam Injection (NBI), Ion Cyclotron Resonant Heting (ICRH)/Fast Wave Current Drive (FWCD), Lower Hybrid Current Drive (LHCD), and Eclectron Cyclotron Heating (ECH)/Electron Cyclotron Current Drive (ECCD). Here, the NBI system is typically used for the central heating and current drive. For the time being, only one NBI device (composed of 3 sources) is available in KSTAR. The first two sources were successfully commissioned in 2010 and 2013. The last source will be installed in 2014. In this work, we present a simulation study of the heating and current drive of the first NBI system (3 sources) during the ramp-up phase. We consider two different NBI configurations (low and high beam energy). The simulation is performed with NUBEAM, a well-recognized Monte-Carlo code. Several different types of KSTAR target equilibria (scan from lower to higher plasma density) are used for the calculation of the current drive, the heating and the different NB losses (shinethrough, charge exchange and bad orbit). The study shows the dependency of those quantities on the plasma density, the position of the NB source and the beam energy. It also shows that because of the shinethrough loss is too high, each NB source cannot be used when the plasma density is under a certain threshold. This study can be used to determine the starting time of the different NB sources during the KSTAR ramp-up phase.

  4. Electron-Cloud Simulation and Theory for High-Current Heavy-Ion Beams

    SciTech Connect

    Cohen, R; Friedman, A; Lund, S; Molvik, A; Lee, E; Azevedo, T; Vay, J; Stoltz, P; Veitzer, S

    2004-07-26

    Stray electrons can arise in positive-ion accelerators for heavy ion fusion or other applications as a result of ionization of ambient gas or gas released from walls due to halo-ion impact, or as a result of secondary- electron emission. We summarize the distinguishing features of electron cloud issues in heavy-ion-fusion accelerators and a plan for developing a self-consistent simulation capability for heavy-ion beams and electron clouds. We also present results from several ingredients in this capability: (1) We calculate the electron cloud produced by electron desorption from computed beam-ion loss, which illustrates the importance of retaining ion reflection at the walls. (2) We simulate of the effect of specified electron cloud distributions on ion beam dynamics. We consider here electron distributions with axially varying density, centroid location, or radial shape, and examine both random and sinusoidally varying perturbations. We find that amplitude variations are most effective in spoiling ion beam quality, though for sinusoidal variations which match the natural ion beam centroid oscillation or breathing mode frequencies, the centroid and shape perturbations can also have significant impact. We identify an instability associated with a resonance between the beam-envelope ''breathing'' mode and the electron perturbation. We estimate its growth rate, which is moderate (compared to the reciprocal of a typical pulse duration). One conclusion from this study is that heavy-ion beams are surprisingly robust to electron clouds, compared to a priori expectations. (3) We report first results from a long-timestep algorithm for electron dynamics, which holds promise for efficient simultaneous solution of electron and ion dynamics.

  5. THE n-DISTRIBUTION OF ELECTRONS AND DOUBLE LAYERS IN THE ELECTRON-BEAM-RETURN-CURRENT SYSTEM OF SOLAR FLARES

    SciTech Connect

    Karlicky, Marian

    2012-05-01

    We investigate processes in the electron-beam-return-current system in the impulsive phase of solar flares to answer a question about the formation of the n-electron distribution detected in this phase of solar flares. An evolution of the electron-beam-return-current system with an initial local density depression is studied using a three-dimensional electromagnetic particle-in-cell model. In the system the strong double layer is formed. Its electric field potential increases with the electron beam flux. In this electric field potential, the electrons of background plasma are strongly accelerated and propagate in the return-current direction. The high-energy part of their distribution at the high-potential side of the strong double layer resembles that of the n-distribution. Thus, the detection of the n-distributions, where a form of the high-energy part of the distribution is the most important, can indicate the presence of strong double layers in solar flares. The similarity between processes in solar flare loops and those in the downward current region of the terrestrial aurora, where the double layers were observed by FAST satellite, supports this idea.

  6. The structure and properties of boron carbide ceramics modified by high-current pulsed electron-beam

    SciTech Connect

    Ivanov, Yuri; Tolkachev, Oleg Petyukevich, Maria Polisadova, Valentina; Teresov, Anton; Ivanova, Olga Ikonnikova, Irina

    2016-01-15

    The present work is devoted to numerical simulation of temperature fields and the analysis of structural and strength properties of the samples surface layer of boron carbide ceramics treated by the high-current pulsed electron-beam of the submillisecond duration. The samples made of sintered boron carbide ceramics are used in these investigations. The problem of calculating the temperature field is reduced to solving the thermal conductivity equation. The electron beam density ranges between 8…30 J/cm{sup 2}, while the pulse durations are 100…200 μs in numerical modelling. The results of modelling the temperature field allowed ascertaining the threshold parameters of the electron beam, such as energy density and pulse duration. The electron beam irradiation is accompanied by the structural modification of the surface layer of boron carbide ceramics either in the single-phase (liquid or solid) or two-phase (solid-liquid) states. The sample surface of boron carbide ceramics is treated under the two-phase state (solid-liquid) conditions of the structural modification. The surface layer is modified by the high-current pulsed electron-beam produced by SOLO installation at the Institute of High Current Electronics of the Siberian Branch of the Russian Academy of Sciences, Tomsk, Russia. The elemental composition and the defect structure of the modified surface layer are analyzed by the optical instrument, scanning electron and transmission electron microscopes. Mechanical properties of the modified layer are determined measuring its hardness and crack resistance. Research results show that the melting and subsequent rapid solidification of the surface layer lead to such phenomena as fragmentation due to a crack network, grain size reduction, formation of the sub-grained structure due to mechanical twinning, and increase of hardness and crack resistance.

  7. The structure and properties of boron carbide ceramics modified by high-current pulsed electron-beam

    NASA Astrophysics Data System (ADS)

    Ivanov, Yuri; Tolkachev, Oleg; Petyukevich, Maria; Teresov, Anton; Ivanova, Olga; Ikonnikova, Irina; Polisadova, Valentina

    2016-01-01

    The present work is devoted to numerical simulation of temperature fields and the analysis of structural and strength properties of the samples surface layer of boron carbide ceramics treated by the high-current pulsed electron-beam of the submillisecond duration. The samples made of sintered boron carbide ceramics are used in these investigations. The problem of calculating the temperature field is reduced to solving the thermal conductivity equation. The electron beam density ranges between 8…30 J/cm2, while the pulse durations are 100…200 μs in numerical modelling. The results of modelling the temperature field allowed ascertaining the threshold parameters of the electron beam, such as energy density and pulse duration. The electron beam irradiation is accompanied by the structural modification of the surface layer of boron carbide ceramics either in the single-phase (liquid or solid) or two-phase (solid-liquid) states. The sample surface of boron carbide ceramics is treated under the two-phase state (solid-liquid) conditions of the structural modification. The surface layer is modified by the high-current pulsed electron-beam produced by SOLO installation at the Institute of High Current Electronics of the Siberian Branch of the Russian Academy of Sciences, Tomsk, Russia. The elemental composition and the defect structure of the modified surface layer are analyzed by the optical instrument, scanning electron and transmission electron microscopes. Mechanical properties of the modified layer are determined measuring its hardness and crack resistance. Research results show that the melting and subsequent rapid solidification of the surface layer lead to such phenomena as fragmentation due to a crack network, grain size reduction, formation of the sub-grained structure due to mechanical twinning, and increase of hardness and crack resistance.

  8. Characterisation of strip silicon detectors for the ATLAS Phase-II Upgrade with a micro-focused X-ray beam

    NASA Astrophysics Data System (ADS)

    Poley, L.; Blue, A.; Bates, R.; Bloch, I.; Díez, S.; Fernandez-Tejero, J.; Fleta, C.; Gallop, B.; Greenall, A.; Gregor, I.-M.; Hara, K.; Ikegami, Y.; Lacasta, C.; Lohwasser, K.; Maneuski, D.; Nagorski, S.; Pape, I.; Phillips, P. W.; Sperlich, D.; Sawhney, K.; Soldevila, U.; Ullan, M.; Unno, Y.; Warren, M.

    2016-07-01

    The planned HL-LHC (High Luminosity LHC) in 2025 is being designed to maximise the physics potential through a sizable increase in the luminosity up to 6·1034 cm-2s-1. A consequence of this increased luminosity is the expected radiation damage at 3000 fb-1 after ten years of operation, requiring the tracking detectors to withstand fluences to over 1·1016 1 MeV neq/cm2. In order to cope with the consequent increased readout rates, a complete re-design of the current ATLAS Inner Detector (ID) is being developed as the Inner Tracker (ITk). Two proposed detectors for the ATLAS strip tracker region of the ITk were characterized at the Diamond Light Source with a 3 μm FWHM 15 keV micro focused X-ray beam. The devices under test were a 320 μm thick silicon stereo (Barrel) ATLAS12 strip mini sensor wire bonded to a 130 nm CMOS binary readout chip (ABC130) and a 320 μm thick full size radial (end-cap) strip sensor - utilizing bi-metal readout layers - wire bonded to 250 nm CMOS binary readout chips (ABCN-25). A resolution better than the inter strip pitch of the 74.5 μm strips was achieved for both detectors. The effect of the p-stop diffusion layers between strips was investigated in detail for the wire bond pad regions. Inter strip charge collection measurements indicate that the effective width of the strip on the silicon sensors is determined by p-stop regions between the strips rather than the strip pitch.

  9. Three-dimensional simulations of high-current beams in induction accelerators with WARP3d

    SciTech Connect

    Grote, D.P.; Friedman, A.; Haber, I.

    1995-09-01

    For many issues relevant to acceleration and propagation of heavy-ion beams for inertial confinement fusion, understanding the behavior of the beam requires the self-consistent inclusion of the self-fields of the beams in multiple dimensions. For these reasons, the three-dimensional simulation code WARP3d A.Friedman was developed. The code combines the particle-in-cell plasma simulation technique with a realistic description of the elements which make up an accelerator. In this paper, the general structure of the code is reviewed and details of two ongoing applications are presented along with a discussion of simulation techniques used. The most important results of this work are presented.

  10. High-efficiency, nickel-ceramic composite anode current collector for micro-tubular solid oxide fuel cells

    NASA Astrophysics Data System (ADS)

    Li, Tao; Wu, Zhentao; Li, K.

    2015-04-01

    High manufacturing cost and low-efficient current collection have been the two major bottlenecks that prevent micro-tubular SOFCs from large-scale application. In this work, a new nickel-based composite anode current collector has been developed for anode-supported MT-SOFC, addressing reduced cost, manufacturability and current collection efficiencies. Triple-layer hollow fibers have been successfully fabricated via a phase inversion-assisted co-extrusion process, during which a thin nickel-based inner layer was uniformly coated throughout the interior anode surface for improved adhesion with superior process economy. 10 wt.% CGO was added into the inner layer to prevent the excessive shrinkage of pure NiO, thus helping to achieve the co-sintering process. The electrochemical performance tests illustrate that samples with the thinnest anodic current collector (15% of the anode thickness) displayed the highest power density (1.07 W cm-2). The impedance analysis and theoretical calculations suggest that inserting the anodic current collector could dramatically reduce the percentage of contact loss down to 6-10 % of the total ohmic loss (compared to 70% as reported in literatures), which proves the high efficiencies of new current collector design. Moreover, the superior manufacturability and process economy suggest this composite current collector suitable for mass-scale production.

  11. Measurement of inclusive neutral current {pi}{sup 0} production on carbon in a few-GeV neutrino beam

    SciTech Connect

    Kurimoto, Y.; Hiraide, K.; Kubo, H.; Matsuoka, K.; Nakajima, Y.; Nakaya, T.; Orme, D.; Otani, M.; Yokoyama, M.; Alcaraz-Aunion, J. L.; Jover-Manas, G.; Sanchez, F.; Brice, S. J.; Finley, D. A.; Kobilarcik, T.; Moore, C. D.; Russell, A. D.; Stefanski, R. J.; Tesarek, R. J.; White, H. B.

    2010-02-01

    The SciBooNE Collaboration reports inclusive neutral current neutral pion production by a muon neutrino beam on a polystyrene target (C{sub 8}H{sub 8}). We obtain (7.7{+-}0.5(stat){+-}0.5(sys))x10{sup -2} as the ratio of the neutral current neutral pion production to total charged current cross section; the mean energy of neutrinos producing detected neutral pions is 1.1 GeV. The result agrees with the Rein-Sehgal model implemented in our neutrino interaction simulation program with nuclear effects. The spectrum shape of the {pi}{sup 0} momentum and angle agree with the model. We also measure the ratio of the neutral current coherent pion production to total charged current cross section to be (0.7{+-}0.4)x10{sup -2}.

  12. Direct activation of cardiac pacemaker channels by intracellular cyclic AMP.

    PubMed

    DiFrancesco, D; Tortora, P

    1991-05-09

    Cyclic AMP acts as a second messenger in the modulation of several ion channels that are typically controlled by a phosphorylation process. In cardiac pacemaker cells, adrenaline and acetylcholine regulate the hyperpolarization-activated current (if), but in opposite ways; this current is involved in the generation and modulation of pacemaker activity. These actions are mediated by cAMP and underlie control of spontaneous rate by neurotransmitters. Whether the cAMP modulation of if is mediated by channel phosphorylation is, however, still unknown. Here we investigate the action of cAMP on if in excised patches of cardiac pacemaker cells and find that cAMP activates if by a mechanism independent of phosphorylation, involving a direct interaction with the channels at their cytoplasmic side. Cyclic AMP activates if by shifting its activation curve to more positive voltages, in agreement with whole-cell results. This is the first evidence of an ion channel whose gating is dually regulated by voltage and direct cAMP binding.

  13. Current Status and Strategy of microRNA Research for Cartilage Development and Osteoarthritis Pathogenesis

    PubMed Central

    2016-01-01

    MicroRNAs (miRNAs), which are small (~21 nucleotides) non-coding RNAs, are important players in endochondral ossification, articular cartilage homeostasis, and arthritis pathogenesis. Comprehensive and genetic analyses of cartilage-specific or cartilage-related miRNAs have provided new information on cartilage development, homeostasis, and related diseases. State-of-the-art combinatorial approaches, including transcription-activator like effector nuclease (TALEN)/clustered regularly interspaced short palindromic repeats (CRISPR) technique for targeting miRNAs and high-throughput sequencing of RNA isolated by cross-linking immunoprecipitation for identifying target messenger RNAs, should be used to determine complex miRNA networks and miRNA-dependent cartilage regulation. Use of advanced drug delivery systems involving cartilage-specific miRNAs will accelerate the application of these new findings in arthritis therapy. PMID:27622175

  14. Comparison of micro-computerized tomography and cone-beam computerized tomography in the detection of accessory canals in primary molars

    PubMed Central

    Kamburoğlu, Kıvanç; Tatar, İlkan; Arıkan, Volkan; Çelik, Hakan Hamdi; Yüksel, Selcen; Özen, Tuncer

    2015-01-01

    Purpose This study was performed to compare the accuracy of micro-computed tomography (CT) and cone-beam computed tomography (CBCT) in detecting accessory canals in primary molars. Materials and Methods Forty-one extracted human primary first and second molars were embedded in wax blocks and scanned using micro-CT and CBCT. After the images were taken, the samples were processed using a clearing technique and examined under a stereomicroscope in order to establish the gold standard for this study. The specimens were classified into three groups: maxillary molars, mandibular molars with three canals, and mandibular molars with four canals. Differences between the gold standard and the observations made using the imaging methods were calculated using Spearman's rho correlation coefficient test. Results The presence of accessory canals in micro-CT images of maxillary and mandibular root canals showed a statistically significant correlation with the stereomicroscopic images used as a gold standard. No statistically significant correlation was found between the CBCT findings and the stereomicroscopic images. Conclusion Although micro-CT is not suitable for clinical use, it provides more detailed information about minor anatomical structures. However, CBCT is convenient for clinical use but may not be capable of adequately analyzing the internal anatomy of primary teeth. PMID:26730367

  15. Effect of high current electron beam in a 30 MeV radio frequency linac for neutron-time-of-flight applications

    SciTech Connect

    Nayak, B. Acharya, S.; Rajawat, R. K.; DasGupta, K.

    2016-01-15

    A high power pulsed radio frequency electron linac is designed by BARC, India to accelerate 30 MeV, 10 A, 10 ns beam for neutron-time-of-flight applications. It will be used as a neutron generator and will produce ∼10{sup 12}–10{sup 13} n/s. It is essential to reduce the beam instability caused by space charge effect and the beam cavity interaction. In this paper, the wakefield losses in the accelerating section due to bunch of RMS (Root mean square) length 2 mm (at the gun exit) is analysed. Loss and kick factors are numerically calculated using CST wakefield solver. Both the longitudinal and transverse wake potentials are incorporated in beam dynamics code ELEGANT to find the transverse emittance growth of the beam propagating through the linac. Beam loading effect is examined by means of numerical computation carried out in ASTRA code. Beam break up start current has been estimated at the end of the linac which arises due to deflecting modes excited by the high current beam. At the end, transverse beam dynamics of such high current beam has been analysed.

  16. Effect of high current electron beam in a 30 MeV radio frequency linac for neutron-time-of-flight applications

    NASA Astrophysics Data System (ADS)

    Nayak, B.; Acharya, S.; Rajawat, R. K.; DasGupta, K.

    2016-01-01

    A high power pulsed radio frequency electron linac is designed by BARC, India to accelerate 30 MeV, 10 A, 10 ns beam for neutron-time-of-flight applications. It will be used as a neutron generator and will produce ˜1012-1013 n/s. It is essential to reduce the beam instability caused by space charge effect and the beam cavity interaction. In this paper, the wakefield losses in the accelerating section due to bunch of RMS (Root mean square) length 2 mm (at the gun exit) is analysed. Loss and kick factors are numerically calculated using CST wakefield solver. Both the longitudinal and transverse wake potentials are incorporated in beam dynamics code ELEGANT to find the transverse emittance growth of the beam propagating through the linac. Beam loading effect is examined by means of numerical computation carried out in ASTRA code. Beam break up start current has been estimated at the end of the linac which arises due to deflecting modes excited by the high current beam. At the end, transverse beam dynamics of such high current beam has been analysed.

  17. Hard alpha-keratin degradation inside a tissue under high flux X-ray synchrotron micro-beam: a multi-scale time-resolved study.

    PubMed

    Leccia, Emilie; Gourrier, Aurélien; Doucet, Jean; Briki, Fatma

    2010-04-01

    X-rays interact strongly with biological organisms. Synchrotron radiation sources deliver very intense X-ray photon fluxes within micro- or submicro cross-section beams, resulting in doses larger than the MGy. The relevance of synchrotron radiation analyses of biological materials is therefore questionable since such doses, million times higher than the ones used in radiotherapy, can cause huge damages in tissues, with regard to not only DNA, but also proteic and lipid organizations. Very few data concerning the effect of very high X-ray doses in tissues are available in the literature. We present here an analysis of the structural phenomena which occur when the model tissue of human hair is irradiated by a synchrotron X-ray micro-beam. The choice of hair is supported by its hierarchical and partially ordered keratin structure which can be analysed inside the tissue by X-ray diffraction. To assess the damages caused by hard X-ray micro-beams (1 microm(2) cross-section), short exposure time scattering SAXS/WAXS patterns have been recorded at beamline ID13 (ESRF) after various irradiation times. Various modifications of the scattering patterns are observed, they provide fine insight of the radiation damages at various hierarchical levels and also unexpectedly provide information about the stability of the various hierarchical structural levels. It appears that the molecular level, i.e. the alpha helices which are stabilized by hydrogen bonds and the alpha-helical coiled coils which are stabilized by hydrophobic interactions, is more sensitive to radiation than the supramolecular architecture of the keratin filament and the filament packing within the keratin associated proteins matrix, which is stabilized by disulphide bonds.

  18. High current density pulsed cathode experiments at SLAC

    SciTech Connect

    Koontz, R.; Fant, K.; Vlieks, A.

    1990-06-01

    A 1.9 microperveance beam diode has been constructed to test high current density cathodes for use in klystrons. Several standard and specially coated dispenser cathodes are being tested. Results of tests to date show average cathode current densities in excess of 25 amps/cm, and maximum electric field gradients of more than 450 kV/cm for pulses of the order of 1{mu}sec. 3 refs., 11 figs.

  19. Beam Interaction Measurements with a Retarding Field Analyzer in a High-Current High-Vacuum Positively-Charged Particle Accelerator

    SciTech Connect

    Covo, M K; Molvik, A W; Friedman, A; Barnard, J J; Seidl, P A; Logan, B G; Baca, D; Vujic, J L

    2006-07-11

    A Retarding Field Analyzer (RFA) was inserted in a drift region of a magnetic transport section of the high-current experiment (HCX) that is at high-vacuum to measure ions and electrons resulting from beam interaction with background gas and walls. The ions are expelled during the beam by the space-charge potential and the electrons are expelled mainly at the end of the beam, when the beam potential decays. The ion energy distribution shows the beam potential of {approx} 2100 V and the beam-background gas total cross-section of 1.6x10{sup -20} m{sup 2}. The electron energy distribution reveals that the expelled electrons are mainly desorbed from the walls and gain {approx} 22 eV from the beam potential decaying with time before entering the RFA. Details of the RFA design and of the measured energy distributions are presented and discussed.

  20. Sediment resuspension by wind, waves, and currents during meteorological frontal passages in a micro-tidal lagoon

    NASA Astrophysics Data System (ADS)

    Carlin, Joseph A.; Lee, Guan-hong; Dellapenna, Timothy M.; Laverty, Paul

    2016-04-01

    Meteorological frontal passages are recognized as important mechanisms for remobilizing sediment in estuaries along the northern Gulf of Mexico, but few studies have addressed factors beyond wind speed as a predictor for resuspension. To better understand resuspension mechanisms during these events, this study investigated the effects of wind, waves, and currents on suspended sediment concentration near the seabed during frontal passages in the shallow, micro-tidal West Galveston Bay located along the Texas coast. In late January and early February 2013, two multi-day deployments of instrumented pods (an acoustic Doppler velocimeter, and an acoustic wave and current profiler) were conducted to capture two separate frontal passages. The results indicate that the bed shear stress under the combined effect of waves and currents showed a much stronger relationship to sediment resuspension (R2 = 0.90) than wind stress alone (R2 = 0.55), or currents alone (R2 = 0.72). Increases in the bed shear stress due to the combined effects of waves and currents resulted from increased wave height, which is strongly related to fetch within the bay. Therefore, understanding fetch-limited wave heights as a function of wind speed and direction, in conjunction with basin geometry, may be a better way to predict sediment resuspension during meteorological frontal passages in the shallow bays of the northern Gulf of Mexico.

  1. Theory of current-drive in plasmas

    SciTech Connect

    Fisch, N.J.

    1986-12-01

    The continuous operation of a tokamak fusion reactor requires, among other things, a means of providing continuous toroidal current. Such operation is preferred to the conventional pulsed operation, where the plasma current is induced by a time-varying magnetic field. A variety of methods has been proposed to provide continuous current, including methods which utilize particle beams or radio frequency waves in any of several frequency regimes. Currents as large as half a mega-amp have now been produced in the laboratory by such means, and experimentation in these techniques has now involved major tokamak facilities worldwide.

  2. Low-cost system for micrometer-resolution solar cell characterization by light beam-induced current mapping

    NASA Astrophysics Data System (ADS)

    Cossutta, H.; Taretto, K.; Troviano, M.

    2014-10-01

    Light-beam induced current (LBIC) mapping is an increasingly utilized characterization technique for laboratory-scale as well as industrial-scale solar cells, which measures the local solar cell photocurrent by point illumination. This contribution demonstrates the design and testing of an LBIC mapping device capable of measuring LBIC maps of solar cells using inexpensive materials. With a spatial resolution of 4 µm and an auto-focused beam spot size of about 2 µm, obtained from a standard CD/DVD pickup, high-resolution LBIC maps of thin-film solar cells are obtained. The system was demonstrated by measuring LBIC maps on thin-film solar cells, revealing significant, micrometer-sized photocurrent heterogeneities that are otherwise unseen when using typical commercial LBIC systems with lower resolution.

  3. Controlling precise magnetic field configuration around electron cyclotron resonance zone for enhancing plasma parameters and beam current.

    PubMed

    Yano, Keisuke; Kurisu, Yosuke; Nozaki, Dai; Kimura, Daiju; Imai, Youta; Kumakura, Sho; Sato, Fuminobu; Kato, Yushi; Iida, Toshiyuki

    2014-02-01

    Multi-charged ion source which has wide operating conditions is required in various application fields. We have constructed tandem type ECR ion source (ECRIS); one of the features of its main stage is an additional coil for controlling magnetic field distribution around the mirror bottom precisely. Here the effect of magnetic field variation caused by the additional coil is experimentally considered in terms of plasma parameters and beam current as the first investigation of the main stage plasma. Furthermore, behavior of magnetic lines of force flowing from the ECR zone is calculated, and is compared with measurement results aiming for better understanding of interrelationship between plasma production and ion beam generation on the ECRIS.

  4. Why Ampère did not discover electromagnetic induction

    NASA Astrophysics Data System (ADS)

    Williams, L. Pearce

    1986-04-01

    In 1832, after Michael Faraday had announced his discovery of electromagnetic induction, Andre-Marie Ampère claimed that he had actually discovered the induction of one current by another in 1822. In fact, he had, but did not really publish the fact at that time. This article explores the reasons for Ampère's failure to lay claim to a discovery that would have guaranteed him scientific immortality.

  5. Defect characterization of Cd0.9Zn0.1Te crystals using electron beam induced current (EBIC) imaging and thermally stimulated current (TSC) measurements

    NASA Astrophysics Data System (ADS)

    Pak, Rahmi O.; Nguyen, Khai V.; Oner, Cihan; Mannan, Mohammad A.; Mandal, Krishna C.

    2015-09-01

    Semi-insulating Cd0.9Zn0.1Te nuclear detector grade crystals were grown by a low temperature solution method from in-house zone refined (~7N) precursor materials. The processed crystals from the grown ingot were thoroughly characterized by using a non-destructive electron beam induced current (EBIC) contrast imaging method. The EBIC results were correlated with the infrared (IR) transmittance mapping, which confirms the variation of contrasts in EBIC is due to non-uniform distribution of tellurium inclusions in the grown CZT crystal. Electrical characteristics of defect regions in the fabricated detectors were further investigated by I-V measurements, and thermally stimulated current (TSC) measurements. Finally, to demonstrate the high quality of the grown CZT crystals, pulse height spectra (PHS) measurements were carried out using gamma radiation sources of 241Am (59.6 keV) and 137Cs (662 keV).

  6. Design of a high-current low-energy beam transport line for an intense D-T/D-D neutron generator

    NASA Astrophysics Data System (ADS)

    Lu, Xiaolong; Wang, Junrun; Zhang, Yu; Li, Jianyi; Xia, Li; Zhang, Jie; Ding, Yanyan; Jiang, Bing; Huang, Zhiwu; Ma, Zhanwen; Wei, Zheng; Qian, Xiangping; Xu, Dapeng; Lan, Changlin; Yao, Zeen

    2016-03-01

    An intense D-T/D-D neutron generator is currently being developed at the Lanzhou University. The Cockcroft-Walton accelerator, as a part of the neutron generator, will be used to accelerate and transport the high-current low-energy beam from the duoplasmatron ion source to the rotating target. The design of a high-current low-energy beam transport (LEBT) line and the dynamics simulations of the mixed beam were carried out using the TRACK code. The results illustrate that the designed beam line facilitates smooth transportation of a deuteron beam of 40 mA, and the number of undesired ions can be reduced effectively using two apertures.

  7. Effects of protein kinase inhibitors on canine Purkinje fibre pacemaker depolarization and the pacemaker current i(f).

    PubMed

    Chang, F; Cohen, I S; DiFrancesco, D; Rosen, M R; Tromba, C

    1991-01-01

    1. The effects of the protein kinase inhibitors H-7 and H-8 were investigated on diastolic depolarization of the action potential with microelectrodes and on the pacemaker current if with the two-microelectrode voltage clamp in canine cardiac Purkinje fibres. 2. Both 200 microM-H-7 and 100 microM-H-8 had no significant effect on the slope of diastolic depolarization but eliminated the actions of isoprenaline (1 microM). 3. We examined the actions of H-7 and H-8 on if in the presence and absence of isoprenaline. H-7 (200 microM) shifted the pacemaker current if in the negative direction on the voltage axis, whereas 100 microM-H-8 had no significant effect by itself. Both 200 microM-H-7 and 100 microM-H-8 can reverse or prevent the actions of isoprenaline (1-5 microM) on if. 4. We applied activators of the cyclic AMP cascade down-stream to the beta-receptor, to further evaluate where H-7 and H-8 might be exerting their effects. When exposing Purkinje fibres to an adenylyl cyclase activator (forskolin, 10-50 microM), a phosphodiesterase inhibitor (IBMX, 100 microM) and a permeable cyclic AMP analogue (8-chlorophenylthio-cyclic AMP, 200 microM-1 mM), the amplitude of if was increased. H-7 and H-8 at 100-200 microM eliminated each of these actions. 5. These results suggest that a phosphorylation process is involved in the modulation of the pacemaker current, if, in Purkinje fibres. The different actions of H-7 and H-8 on basal if suggest the hypothesis that other protein kinases, possibly protein kinase C, might also be involved in regulating basal phosphorylation of if in Purkinje fibres.

  8. Effects of protein kinase inhibitors on canine Purkinje fibre pacemaker depolarization and the pacemaker current i(f).

    PubMed Central

    Chang, F; Cohen, I S; DiFrancesco, D; Rosen, M R; Tromba, C

    1991-01-01

    1. The effects of the protein kinase inhibitors H-7 and H-8 were investigated on diastolic depolarization of the action potential with microelectrodes and on the pacemaker current if with the two-microelectrode voltage clamp in canine cardiac Purkinje fibres. 2. Both 200 microM-H-7 and 100 microM-H-8 had no significant effect on the slope of diastolic depolarization but eliminated the actions of isoprenaline (1 microM). 3. We examined the actions of H-7 and H-8 on if in the presence and absence of isoprenaline. H-7 (200 microM) shifted the pacemaker current if in the negative direction on the voltage axis, whereas 100 microM-H-8 had no significant effect by itself. Both 200 microM-H-7 and 100 microM-H-8 can reverse or prevent the actions of isoprenaline (1-5 microM) on if. 4. We applied activators of the cyclic AMP cascade down-stream to the beta-receptor, to further evaluate where H-7 and H-8 might be exerting their effects. When exposing Purkinje fibres to an adenylyl cyclase activator (forskolin, 10-50 microM), a phosphodiesterase inhibitor (IBMX, 100 microM) and a permeable cyclic AMP analogue (8-chlorophenylthio-cyclic AMP, 200 microM-1 mM), the amplitude of if was increased. H-7 and H-8 at 100-200 microM eliminated each of these actions. 5. These results suggest that a phosphorylation process is involved in the modulation of the pacemaker current, if, in Purkinje fibres. The different actions of H-7 and H-8 on basal if suggest the hypothesis that other protein kinases, possibly protein kinase C, might also be involved in regulating basal phosphorylation of if in Purkinje fibres. PMID:1804968

  9. Change in Ion Beam Induced Current from Si Metal-Oxide-Semiconductor Capacitors after Gamma-Ray Irradiation

    SciTech Connect

    Ohshima, T.; Onoda, S.; Hirao, T.; Takahashi, Y.; Vizkelethy, G.; Doyle, B. L.

    2009-03-10

    To investigate the effects of gamma-ray irradiation on transient current induced in MOS capacitors by heavy ion incidence, Si MOS capacitors were irradiated with gamma-rays up to 60.9 kGy(SiO2). The change in Transient Ion Beam Induced Current (TIBIC) signals due to gamma-ray irradiation was investigated using 15 MeV-oxygen ion microbeams. After gamma-ray irradiation, the peak current of the TIBIC signal vs. bias voltage curve shifted toward negative voltages. This shift can be interpreted in terms of the charge trapped in the oxide. In this dose range, no significant effects of the interface traps induced by gamma-ray irradiation on the TIBIC signals were observed.

  10. Overview of Alternative Bunching and Current-shaping Techniques for Low-Energy Electron Beams

    SciTech Connect

    Piot, Philippe

    2015-12-01

    Techniques to bunch or shape an electron beam at low energies (E <15 MeV) have important implications toward the realization of table-top radiation sources [1] or to the design of compact multi-user free-electron lasers[2]. This paper provides an overview of alternative methods recently developed including techniques such as wakefield-based bunching, space-charge-driven microbunching via wave-breaking [3], ab-initio shaping of the electron-emission process [4], and phase space exchangers. Practical applications of some of these methods to foreseen free-electron-laser configurations are also briefly discussed [5].

  11. Multiocular image sensor with on-chip beam-splitter and inner meta-micro-lens for single-main-lens stereo camera.

    PubMed

    Koyama, Shinzo; Onozawa, Kazutoshi; Tanaka, Keisuke; Saito, Shigeru; Kourkouss, Sahim Mohamed; Kato, Yoshihisa

    2016-08-08

    We developed multiocular 1/3-inch 2.75-μm-pixel-size 2.1M- pixel image sensors by co-design of both on-chip beam-splitter and 100-nm-width 800-nm-depth patterned inner meta-micro-lens for single-main-lens stereo camera systems. A camera with the multiocular image sensor can capture horizontally one-dimensional light filed by both the on-chip beam-splitter horizontally dividing ray according to incident angle, and the inner meta-micro-lens collecting the divided ray into pixel with small optical loss. Cross-talks between adjacent light field images of a fabricated binocular image sensor and of a quad-ocular image sensor are as low as 6% and 7% respectively. With the selection of two images from one-dimensional light filed images, a selective baseline for stereo vision is realized to view close objects with single-main-lens. In addition, by adding multiple light field images with different ratios, baseline distance can be tuned within an aperture of a main lens. We suggest the electrically selective or tunable baseline stereo vision to reduce 3D fatigue of viewers.

  12. High-energy transmission Laue micro-beam X-ray diffraction: a probe for intra-granular lattice orientation and elastic strain in thicker samples.

    PubMed

    Hofmann, Felix; Song, Xu; Abbey, Brian; Jun, Tea-Sung; Korsunsky, Alexander M

    2012-05-01

    An understanding of the mechanical response of modern engineering alloys to complex loading conditions is essential for the design of load-bearing components in high-performance safety-critical aerospace applications. A detailed knowledge of how material behaviour is modified by fatigue and the ability to predict failure reliably are vital for enhanced component performance. Unlike macroscopic bulk properties (e.g. stiffness, yield stress, etc.) that depend on the average behaviour of many grains, material failure is governed by `weakest link'-type mechanisms. It is strongly dependent on the anisotropic single-crystal elastic-plastic behaviour, local morphology and microstructure, and grain-to-grain interactions. For the development and validation of models that capture these complex phenomena, the ability to probe deformation behaviour at the micro-scale is key. The diffraction of highly penetrating synchrotron X-rays is well suited to this purpose and micro-beam Laue diffraction is a particularly powerful tool that has emerged in recent years. Typically it uses photon energies of 5-25 keV, limiting penetration into the material, so that only thin samples or near-surface regions can be studied. In this paper the development of high-energy transmission Laue (HETL) micro-beam X-ray diffraction is described, extending the micro-beam Laue technique to significantly higher photon energies (50-150 keV). It allows the probing of thicker sample sections, with the potential for grain-level characterization of real engineering components. The new HETL technique is used to study the deformation behaviour of individual grains in a large-grained polycrystalline nickel sample during in situ tensile loading. Refinement of the Laue diffraction patterns yields lattice orientations and qualitative information about elastic strains. After deformation, bands of high lattice misorientation can be identified in the sample. Orientation spread within individual scattering volumes is

  13. An annular high-current electron beam with an energy spread in a coaxial magnetically insulated diode

    SciTech Connect

    Grishkov, A. A. Pegel, I. V.

    2013-11-15

    An elementary theory of an annular high-current electron beam in a uniform transport channel and a coaxial magnetically insulated diode is generalized to the case of counterpropagating electron beams with a spread over kinetic energies. Expressions for the sum of the absolute values of the forward and backward currents in a uniform transport channel and for the flux of the longitudinal component of the generalized momentum in a coaxial magnetically insulated diode as functions of the maximum electron kinetic energy are derived for different values of the relative width of the energy distribution function. It is shown that, in a diode with an expanding transport channel and a virtual cathode limiting the extracted current, counterpropagating particle flows are established between the cathode and the virtual cathode within a certain time interval after the beginning of electron emission. The accumulation of electrons in these flows is accompanied by an increase in their spread over kinetic energies and the simultaneous decrease in the maximum kinetic energy. The developed model agrees with the results of particle-in-cell simulations performed using the KARAT and OOPIC-Pro codes.

  14. High speed, intermediate resolution, large area laser beam induced current imaging and laser scribing system for photovoltaic devices and modules.

    PubMed

    Phillips, Adam B; Song, Zhaoning; DeWitt, Jonathan L; Stone, Jon M; Krantz, Patrick W; Royston, John M; Zeller, Ryan M; Mapes, Meghan R; Roland, Paul J; Dorogi, Mark D; Zafar, Syed; Faykosh, Gary T; Ellingson, Randy J; Heben, Michael J

    2016-09-01

    We have developed a laser beam induced current imaging tool for photovoltaic devices and modules that utilizes diode pumped Q-switched lasers. Power densities on the order of one sun (100 mW/cm(2)) can be produced in a ∼40 μm spot size by operating the lasers at low diode current and high repetition rate. Using galvanostatically controlled mirrors in an overhead configuration and high speed data acquisition, large areas can be scanned in short times. As the beam is rastered, focus is maintained on a flat plane with an electronically controlled lens that is positioned in a coordinated fashion with the movements of the mirrors. The system can also be used in a scribing mode by increasing the diode current and decreasing the repetition rate. In either mode, the instrument can accommodate samples ranging in size from laboratory scale (few cm(2)) to full modules (1 m(2)). Customized LabVIEW programs were developed to control the components and acquire, display, and manipulate the data in imaging mode.

  15. High speed, intermediate resolution, large area laser beam induced current imaging and laser scribing system for photovoltaic devices and modules

    NASA Astrophysics Data System (ADS)

    Phillips, Adam B.; Song, Zhaoning; DeWitt, Jonathan L.; Stone, Jon M.; Krantz, Patrick W.; Royston, John M.; Zeller, Ryan M.; Mapes, Meghan R.; Roland, Paul J.; Dorogi, Mark D.; Zafar, Syed; Faykosh, Gary T.; Ellingson, Randy J.; Heben, Michael J.

    2016-09-01

    We have developed a laser beam induced current imaging tool for photovoltaic devices and modules that utilizes diode pumped Q-switched lasers. Power densities on the order of one sun (100 mW/cm2) can be produced in a ˜40 μm spot size by operating the lasers at low diode current and high repetition rate. Using galvanostatically controlled mirrors in an overhead configuration and high speed data acquisition, large areas can be scanned in short times. As the beam is rastered, focus is maintained on a flat plane with an electronically controlled lens that is positioned in a coordinated fashion with the movements of the mirrors. The system can also be used in a scribing mode by increasing the diode current and decreasing the repetition rate. In either mode, the instrument can accommodate samples ranging in size from laboratory scale (few cm2) to full modules (1 m2). Customized LabVIEW programs were developed to control the components and acquire, display, and manipulate the data in imaging mode.

  16. A reassessment of the modulatory role of cyclic AMP in catecholamine secretion by chromaffin cells.

    PubMed Central

    Parramón, M; González, M P; Oset-Gasque, M J

    1995-01-01

    1. The role of adenosine 3':5'-cyclic monophosphate (cyclic AMP) in the regulation of catecholamine (CA) secretion in chromaffin cells remains equivocal from previous studies. 2. In the present study the effect of this cyclic nucleotide on basal CA secretion, as well as on intracellular calcium and membrane potential has been examined. 3. Forskolin and the permeable cyclic AMP analogue, 8-(4-chlorphenylthio)-adenosine-3'-5' monophosphate cyclic (pClpcAMP), increased basal CA secretion in a dose-dependent manner. The EC50s were 0.43 +/- 0.10 microM for forskolin and 39 +/- 9 microM for pClpcAMP. Other agonists with adenylate cyclase activity such as stimulants of adenosine receptors, beta-adrenoceptors, GABAB receptors and intestinal vasoactive peptide (VIP), also increased basal CA secretion in a highly significant manner. However, when they were added together with forskolin, CA secretion was not affected although an additive increase in cyclic AMP levels was produced. 4. Statistical analysis of the correlation between cyclic AMP levels and CA secretion evoked by these cyclic AMP increasing compounds showed that a significant direct correlation between both parameters existed only when low levels of cyclic AMP were produced by secretagogue stimulation. When the increase in intracellular cyclic AMP concentrations exceeded approximately 8 times the basal cyclic AMP levels the correlation was not significant. These results indicate a dual dose-dependent effect of cyclic AMP on basal CA secretion.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:7881750

  17. Collective acceleration of electrons and ions in a high current relativistic electron beam. Final report

    SciTech Connect

    Nation, J.A.

    1992-12-31

    This report describes work carried out on DOE contract number DE-AC02-80ER10569 during the period December 15, 1979 to May 31, 1992. The original purpose of this research was to investigate the use of slow space charge waves on weakly relativistic electron beams for ion acceleration. The work had three major objectives: development of a suitable ion injector, growth and study of the properties of slow space charge waves on an electron beam, and a combination of the two components into a suitable proof-of-principle demonstration of the wave accelerator. Work focused on the first two of these objectives. Control of the space charge waves` phase velocity was not obtained to the degree required for a working accelerator, so the project was duly terminated in favor of a program which focused on generating ultra high power microwave signals suitable for use in the next linear collider. Work done to develop suitable efficient, inexpensive, phase-stable microwave sources, with peak powers of up to 1 GW in the X band in pulses shorter than 1 ns, is described. Included are lists of the journal and conference papers resulting from this work, as well as a list of graduate students who completed their Ph.D. studies on the projects described in this report.

  18. Investigating Effects of Nano- to Micro-Ampere Alternating Current Stimulation on Trichophyton rubrum Growth

    PubMed Central

    Kwon, Dong Rak; Kwon, Hyunjung; Lee, Woo Ram

    2016-01-01

    Background Fungi are eukaryotic microorganisms including yeast and molds. Many studies have focused on modifying bacterial growth, but few on fungal growth. Microcurrent electricity may stimulate fungal growth. Objective This study aims to investigate effects of microcurrent electric stimulation on Trichophyton rubrum growth. Methods Standard-sized inoculums of T. rubrum derived from a spore suspension were applied to potato dextrose cornmeal agar (PDACC) plates, gently withdrawn with a sterile pipette, and were applied to twelve PDACC plates with a sterile spreader. Twelve Petri dishes were divided into four groups. The given amperage of electric current was 500 nA, 2 µA, and 4 µA in groups A, B, and C, respectively. No electric current was given in group D. Results In the first 48 hours, colonies only appeared in groups A and B (500 nA and 2 µA exposure). Colonies in group A (500 nA) were denser. Group C (4 µA) plates showed a barely visible film of fungus after 96 hours of incubation. Fungal growth became visible after 144 hours in the control group. Conclusion Lower intensities of electric current caused faster fungal growth within the amperage range used in this study. Based on these results, further studies with a larger sample size, various fungal species, and various intensities of electric stimulation should be conducted. PMID:27746636

  19. High-Resolution X-Ray and Light Beam Induced Current (LBIC) Measurements of Multcrystalline Silicon Solar Cells

    SciTech Connect

    Jellison Jr, Gerald Earle; Budai, John D; Bennett, Charlee J C; Tischler, Jonathan Zachary; Duty, Chad E; Yelundur, V.; Rohatgi, A.

    2010-01-01

    High-resolution, spatially-resolved x-ray Laue patterns and high-resolution light beam induced current (LBIC) measurements are combined to study two multicrystalline solar cells made from the Heat Exchanger Method (HEM) and the Sting Ribbon Growth technique. The LBIC measurements were made at 4 different wavelengths (488, 633, 780, and 980 nm), resulting in penetration depths ranging from <1 {mu}m to >100 {mu}m. There is a strong correlation between the x-ray and LBIC measurements, showing that some twins and grain boundaries are effective in the reduction of local quantum efficiency, while others are benign.

  20. High-current long-duration uniform electron beam generation in a diode with multicapillary carbon-epoxy cathode

    SciTech Connect

    Queller, T.; Gleizer, J. Z.; Krasik, Ya. E.

    2013-09-28

    The results of reproducibly generating an electron beam with a current density of up to 5 kA/cm{sup 2}, without the cathode-anode gap being shorted by the plasma formed inside the cathode carbon-epoxy capillaries, in a ∼350 kV, ∼600 ns diode, with and without an external guiding magnetic field, are presented. The cathode sustained hundreds of pulses without degradation of its emission properties. Time- and space-resolved emissions of the plasma and spectroscopy analyses were used to determine the cathode plasma's density, temperature, and expansion velocity.

  1. The influence of guiding magnetic field on beam current and plasma expansion in foil-less diode

    SciTech Connect

    Wu, Ping; Ye, Hu; Sun, Jun

    2015-06-15

    The impedance collapse phenomenon in planar diodes has been widely investigated and is believed to be induced by the axial plasma expansion. However, there are few studies about the impedance collapse phenomenon in foil-less diodes, which may occur under a low guiding magnetic field and cannot be explained by the axial plasma expansion. This paper tries to explain this phenomenon by constructing a physical model with consideration of the radial expansion of cathode plasmas. Our physical model can quantitatively describe the formation process of beam current in experiments with reasonable parameters, and it demonstrates that a lower guiding magnetic field will lead to a faster radial plasma expansion speed.

  2. Microstructural, textural and hardness evolution of commercially pure Zr surface-treated by high current pulsed electron beam

    NASA Astrophysics Data System (ADS)

    Chai, Linjiang; Chen, Baofeng; Wang, Shuyan; Zhang, Zhuo; Murty, Korukonda L.

    2016-12-01

    High current pulsed electron beam (HCPEB) treatments were performed for a commercially pure Zr sheet, with remarkable surface modifications demonstrated. After the HCPEB treatments, the prior equiaxed grains with a bimodal basal texture are replaced by ultra fine plates with dense nanotwins and an unusual fiber texture of < 11 2 bar 0 > normal to the sheet surface. Increased number of pulses leads to further refined microstructures and intensified textures, jointly resulting in continuous increase of hardness. Reasons for such modifications could mainly be attributed to ultra fast heating/cooling and strong variant selection due to presence of complex thermal and stress fields.

  3. On-line measurements of proton beam current from a PET cyclotron using a thin aluminum foil

    NASA Astrophysics Data System (ADS)

    Ghithan, S.; do Carmo, S. J. C.; Ferreira Marques, R.; Fraga, F. A. F.; Simões, H.; Alves, F.; Crespo, P.

    2013-07-01

    The number of cyclotrons capable of accelerating protons to about 20 MeV is increasing throughout the world. Originally aiming at the production of positron emission tomography (PET) radionuclides, some of these facilities are equipped with several beam lines suitable for scientific research. Radiobiology, radiophysiology, and other dosimetric studies can be performed using these beam lines. In this work, we measured the Bragg peak of the protons from a PET cyclotron using a stacked target consisting of several aluminum foils interleaved with polyethylene sheets, readout by in-house made transimpedance electronics. The measured Bragg peak is consistent with simulations performed using the SRIM/TRIM simulation toolkit. Furthermore, we report on experimental results aiming at measuring proton beam currents down to 10 pA using a thin aluminum foil (20-μm-thick). The aluminum was chosen for this task because it is radiation hard, it has low density and low radiation activity, and finally because it is easily available at negligible cost. This method allows for calculating the dose delivered to a target during an irradiation with high efficiency, and with minimal proton energy loss and scattering.

  4. Safeguards Technology Factsheet - Unattended Dual Current Monitor (UDCM)

    SciTech Connect

    Newell, Matthew R.

    2016-04-13

    The UDCM is a low-current measurement device designed to record sub-nano-amp to micro-amp currents from radiation detectors. The UDCM is a two-channel device that incorporates a Commercial-Off-The-Shelf (COTS) processor enabling both serial over USB as well as Ethernet communications. The instrument includes microSD and USB flash memory for data storage as well as a programmable High Voltage (HV) power supply for detector bias. The UDCM is packaged in the same enclosure, employs the same processor and has a similar user interface as the UMSR. A serial over USB communication line to the UDCM allows the use of existing versions of MIC software, while the Ethernet port is compatible with the new IAEA RAINSTORM communication protocol.

  5. Synchrotron X-ray Studies of the Keel of the Short-Spined Sea Urchin Lytechinus variegatus: Absorption Microtomography (microCT) and Small Beam Diffraction Mapping

    SciTech Connect

    Stock, S. R.; Barss, J.; Dahl, T.; Veis, A.; Almer, J. D.; De Carlo, F.

    2003-05-01

    In sea urchin teeth, the keel plays an important structural role, and this paper reports results of microstructural characterization of the keel of Lytechinus variegatus using two noninvasive synchrotron x-ray techniques: x-ray absorption microtomography (microCT) and x-ray diffraction mapping. MicroCT with 14 keV x-rays mapped the spatial distribution of mineral at the 1.3 microm level in a millimeter-sized fragment of a mature portion of the keel. Two rows of low absorption channels (i.e., primary channels) slightly less than 10 microm in diameter were found running linearly from the flange to the base of the keel and parallel to its sides. The primary channels paralleled the oral edge of the keel, and the microCT slices revealed a planar secondary channel leading from each primary channel to the side of the keel. The primary and secondary channels were more or less coplanar and may correspond to the soft tissue between plates of the carinar process. Transmission x-ray diffraction with 80.8 keV x-rays and a 0.1 mm beam mapped the distribution of calcite crystal orientations and the composition Ca(1-x)Mg(x)CO(3) of the calcite. Unlike the variable Mg concentration and highly curved prisms found in the keel of Paracentrotus lividus, a constant Mg content (x = 0.13) and relatively little prism curvature was found in the keel of Lytechinus variegatus.

  6. Current-driven ion-acoustic and potential-relaxation instabilities excited in plasma plume during electron beam welding

    SciTech Connect

    Trushnikov, D. N.; Mladenov, G. M. Koleva, E. G.; Belenkiy, V. Ya. Varushkin, S. V.

    2014-04-15

    Many papers have sought correlations between the parameters of secondary particles generated above the beam/work piece interaction zone, dynamics of processes in the keyhole, and technological processes. Low- and high-frequency oscillations of the current, collected by plasma have been observed above the welding zone during electron beam welding. Low-frequency oscillations of secondary signals are related to capillary instabilities of the keyhole, however; the physical mechanisms responsible for the high-frequency oscillations (>10 kHz) of the collected current are not fully understood. This paper shows that peak frequencies in the spectra of the collected high-frequency signal are dependent on the reciprocal distance between the welding zone and collector electrode. From the relationship between current harmonics frequency and distance of the collector/welding zone, it can be estimated that the draft velocity of electrons or phase velocity of excited waves is about 1600 m/s. The dispersion relation with the properties of ion-acoustic waves is related to electron temperature 10 000 K, ion temperature 2 400 K and plasma density 10{sup 16} m{sup −3}, which is analogues to the parameters of potential-relaxation instabilities, observed in similar conditions. The estimated critical density of the transported current for creating the anomalous resistance state of plasma is of the order of 3 A·m{sup −2}, i.e. 8 mA for a 3–10 cm{sup 2} collector electrode. Thus, it is assumed that the observed high-frequency oscillations of the current collected by the positive collector electrode are caused by relaxation processes in the plasma plume above the welding zone, and not a direct demonstration of oscillations in the keyhole.

  7. Electron density profile measurements at a self-focusing ion beam with high current density and low energy extracted through concave electrodes

    SciTech Connect

    Fujiwara, Y. Nakamiya, A.; Sakakita, H.; Hirano, Y.; Kiyama, S.; Koguchi, H.

    2014-02-15

    The self-focusing phenomenon has been observed in a high current density and low energy ion beam. In order to study the mechanism of this phenomenon, a special designed double probe to measure the electron density and temperature is installed into the chamber where the high current density ion beam is injected. Electron density profile is successfully measured without the influence of the ion beam components. Estimated electron temperature and density are ∼0.9 eV and ∼8 × 10{sup 8} cm{sup −3} at the center of ion beam cross section, respectively. It was found that a large amount of electrons are spontaneously accumulated in the ion beam line in the case of self-forcing state.

  8. Ultra-low current beams in UMER to model space-charge effects in high-energy proton and ion machines

    NASA Astrophysics Data System (ADS)

    Bernal, S.; Beaudoin, B.; Baumgartner, H.; Ehrenstein, S.; Haber, I.; Koeth, T.; Montgomery, E.; Ruisard, K.; Sutter, D.; Yun, D.; Kishek, R. A.

    2017-03-01

    The University of Maryland Electron Ring (UMER) has operated traditionally in the regime of strong space-charge dominated beam transport, but small-current beams are desirable to significantly reduce the direct (incoherent) space-charge tune shift as well as the tune depression. This regime is of interest to model space-charge effects in large proton and ion rings similar to those used in nuclear physics and spallation neutron sources, and also for nonlinear dynamics studies of lattices inspired on the Integrable Optics Test Accelerator (IOTA). We review the definitions of beam vs. space-charge intensities and discuss three methods for producing very small beam currents in UMER. We aim at generating 60µA - 1.0mA, 100 ns, 10 keV beams with normalized rms emittances of the order of 0.1 - 1.0µm.

  9. Probing droplets with biological colloidal suspensions on smart surfaces by synchrotron radiation micro- and nano-beams

    NASA Astrophysics Data System (ADS)

    Marinaro, G.; Accardo, A.; Benseny-Cases, N.; Burghammer, M.; Castillo-Michel, H.; Cotte, M.; Dante, S.; De Angelis, F.; Di Cola, E.; Di Fabrizio, E.; Hauser, C.; Riekel, C.

    2016-01-01

    Droplets with colloidal biological suspensions evaporating on substrates with defined wetting properties generate confined environments for initiating aggregation and self-assembly processes. We describe smart micro- and nanostructured surfaces, optimized for probing single droplets and residues by synchrotron radiation micro- and nanobeam diffraction techniques. Applications are presented for Ac-IVD and β-amyloid (1-42) peptides capable of forming cross-β sheet structures. Complementary synchrotron radiation FTIR microspectroscopy addresses secondary structure formation. The high synchrotron radiation source brilliance enables fast raster-scan experiments.

  10. History and modern applications of nano-composite materials carrying GA/cm2 current density due to a Bose-Einstein Condensate at room temperature produced by Focused Electron Beam Induced Processing for many extraordinary novel technical applications

    NASA Astrophysics Data System (ADS)

    Koops, Hans W. P.

    2015-12-01

    The discovery of Focused Electron Beam Induced Processing and early applications of this technology led to the possible use of a novel nanogranular material “Koops-GranMat®” using Pt/C and Au/C material. which carries at room temperature a current density > 50 times the current density which high TC superconductors can carry. The explanation for the characteristics of this novel material is given. This fact allows producing novel products for many applications using Dual Beam system having a gas supply and X.Y.T stream data programming and not using GDSII layout pattern control software. Novel products are possible for energy transportation. -distribution.-switching, photon-detection above 65 meV energy for very efficient energy harvesting, for bright field emission electron sources used for vacuum electronic devices like amplifiers for HF electronics, micro-tubes, 30 GHz to 6 THz switching amplifiers with signal to noise ratio >10(!), THz power sources up to 1 Watt, in combination with miniaturized vacuum pumps, vacuum gauges, IR to THz detectors, EUV- and X-Ray sources. Since focusing electron beam induced deposition works also at low energy, selfcloning multibeam-production machines for field emitter lamps, displays, multi-beam - lithography, - imaging, and - inspection, energy harvesting, and power distribution with switches controlling field-emitter arrays for KA of currents but with < 100 V switching voltage are possible. Finally the replacement of HTC superconductors and its applications by the Koops-GranMat® having Koops-Pairs at room temperature will allow the investigation devices similar to Josephson Junctions and its applications now called QUIDART (Quantum interference devices at Room Temperature). All these possibilities will support a revolution in the optical, electric, power, and electronic technology.

  11. High-Current-Density Thermionic Cathodes and the Generation of High-Voltage Electron Beams

    DTIC Science & Technology

    1989-04-30

    pulsing results, up to 140 kV was applied across this length of boron nitride without surface flashover . The anode face plate is made of stainless steel...current distribution over the cathode surface and correlation with thermionic-emission theory , 3. sign and testing of an electron-gun diode with an...aperture across the cathode surface by moving the anode transversely. The arrangement is shown in Figure 5. The sampled cathode current (0.16 percent of

  12. Development of a low-energy and high-current pulsed neutral beam injector with a washer-gun plasma source for high-beta plasma experiments.

    PubMed

    Ii, Toru; Gi, Keii; Umezawa, Toshiyuki; Asai, Tomohiko; Inomoto, Michiaki; Ono, Yasushi

    2012-08-01

    We have developed a novel and economical neutral-beam injection system by employing a washer-gun plasma source. It provides a low-cost and maintenance-free ion beam, thus eliminating the need for the filaments and water-cooling systems employed conventionally. In our primary experiments, the washer gun produced a source plasma with an electron temperature of approximately 5 eV and an electron density of 5 × 10(17) m(-3), i.e., conditions suitable for ion-beam extraction. The dependence of the extracted beam current on the acceleration voltage is consistent with space-charge current limitation, because the observed current density is almost proportional to the 3/2 power of the acceleration voltage below approximately 8 kV. By optimizing plasma formation, we successfully achieved beam extraction of up to 40 A at 15 kV and a pulse length in excess of 0.25 ms. Its low-voltage and high-current pulsed-beam properties enable us to apply this high-power neutral beam injection into a high-beta compact torus plasma characterized by a low magnetic field.

  13. Collective microdynamics and noise suppression in dispersive electron beam transport

    SciTech Connect

    Gover, Avraham; Dyunin, Egor; Duchovni, Tamir; Nause, Ariel

    2011-12-15

    A general formulation is presented for deep collective interaction micro-dynamics in dispersive e-beam transport. In the regime of transversely coherent interaction, the formulation is applicable to both coherent and random temporal modulation of the electron beam. We demonstrate its use for determining the conditions for suppressing beam current noise below the classical shot-noise level by means of transport through a dispersive section with a small momentum compaction parameter.

  14. Experiment definition studies for AMPS Spacelab

    NASA Technical Reports Server (NTRS)

    Liemohn, H.

    1975-01-01

    The electrical charging of the space shuttle orbiter is discussed in relation to the AMPS Spacelab payload along with an operations research technique for the selection of AMPS Spacelab experiments. Experiments proposed for AMPS include: hydromagnetic wave experiments; bistatic sounder of AMPS wake; and an artificial meteor gun. Experiment objectives and instrument functions are given for all experiments.

  15. Non-inductive current built-up by local electron cyclotron heating and current drive with a 28 GHz focused beam on QUEST

    NASA Astrophysics Data System (ADS)

    Onchi, Takumi; Idei, Hiroshi; Hasegawa, Makoto; Ohwada, Hiroaki; Zushi, Hideki; Hanada, Kazuaki; Kariya, Tsuyoshi; Mishra, Kishore; Shikama, Taichi; Quest Team

    2016-10-01

    The plasma current can be driven solely by injecting electron cyclotron waves (ECWs) in spherical tokamak (ST) configuration. A system of 28 GHz gyrotron (maximum power: 270 kW) is renewed and reinstalled on QUEST. A focused ECW beam, whose diameter is about 5 cm at the second harmonic resonance, is injected for local ECW heating and current drive. The local power density at resonance exceeds 75 MW/m2 at an injection power of 150 kW. The incident ECW polarization can be adjusted employing the phase shifter consisting of two corrugated plates. During 1.25 second pulse of ECH, plasma current is built up to Ip = 70 kA fully non-inductively with a core electron density of ne > 1018 m-3. The closed flux in such ST plasma is determined at the inboard limiter on the center stack. Energetic electrons are also responsible for the pressure and equilibrium. This work is supported by JSPS KAKENHI (15H04231, 15K17800), NIFS Collaboration Research program (NIFS13KUTR085, NIFS11KUTR069, NIFS16KUTR114).

  16. Studies and optimization of Pohang Light Source-II superconducting radio frequency system at stable top-up operation with beam current of 400 mA

    SciTech Connect

    Joo, Youngdo Yu, Inha; Park, Insoo; Chun, Myunghwan; Lee, Byung-Joon; Hwang, Ilmoon; Ha, Taekyun; Shin, Seunghwan; Sohn, Younguk

    2014-12-21

    After three years of upgrading work, the Pohang Light Source-II (PLS-II) is now successfully operating. The final quantitative goal of PLS-II is a top-up user-service operation with beam current of 400 mA to be completed by the end of 2014. During the beam store test up to 400 mA in the storage ring (SR), it was observed that the vacuum pressure around the radio frequency (RF) window of the superconducting cavity rapidly increases over the interlock level limiting the availability of the maximum beam current storing. Although available beam current is enhanced by setting a higher RF accelerating voltage, it is better to keep the RF accelerating voltage as low as possible in the long time top-up operation. We investigated the cause of the window vacuum pressure increment by studying the changes in the electric field distribution at the superconducting cavity and waveguide according to the beam current. In our simulation, an equivalent physical modeling was developed using a finite-difference time-domain code. The simulation revealed that the electric field amplitude at the RF window is exponentially increased as the beam current increases, thus this high electric field amplitude causes a RF breakdown at the RF window, which comes with the rapid increase of window vacuum pressure. The RF accelerating voltage of PLS-II RF system was set to 4.95 MV, which was estimated using the maximum available beam current that works as a function of RF voltage, and the top-up operation test with the beam current of 400 mA was successfully carried out.

  17. Electron-beam-deposited thin polymer films - Electrical properties vs bombarding current.

    NASA Technical Reports Server (NTRS)

    Babcock, L. E.; Christy, R. W.

    1972-01-01

    Polymer films about 150 A thick, deposited on glass substrates by electron bombardment of tetramethyltetraphenyltrisiloxane, were studied, after being sandwiched between evaporated aluminum electrodes, the top one semitransparent. The capacitance, conductance, and photoconductance of the sandwiches were measured at room temperature as a function of the electron bombarding current which formed the polymer. The polymer thickness was obtained independently from Christy's (1960) empirical formula for the rate of formation. The obtained results indicate that, with increasing bombarding current, the polymer undergoes an increase in both crosslinking bonds and dangling bonds. Exposure to air drastically reduces the density of dangling bonds, but does not affect the crosslinking.

  18. Controlling Charge and Current Neutralization of an Ion Beam Pulse in a Background Plasma by Application of a Solenoidal Magnetic Field I: Weak Magnetic Field Limit

    SciTech Connect

    Kaganovich, I. D., Startsev, E. A., Sefkow, A. B., Davidson, R. C.

    2008-10-10

    Propagation of an intense charged particle beam pulse through a background plasma is a common problem in astrophysics and plasma applications. The plasma can effectively neutralize the charge and current of the beam pulse, and thus provides a convenient medium for beam transport. The application of a small solenoidal magnetic field can drastically change the self-magnetic and self- electric fields of the beam pulse, thus allowing effective control of the beam transport through the background plasma. An analytic model is developed to describe the self-magnetic field of a finite- length ion beam pulse propagating in a cold background plasma in a solenoidal magnetic field. The analytic studies show that the solenoidal magnetic field starts to infuence the self-electric and self-magnetic fields when ωce > ωpeβb, where ωce = eβ/mec is the electron gyrofrequency, ωpe is the electron plasma frequency, and βb = Vb/c is the ion beam velocity relative to the speed of light. This condition typically holds for relatively small magnetic fields (about 100G). Analytical formulas are derived for the effective radial force acting on the beam ions, which can be used to minimize beam pinching. The results of analytic theory have been verified by comparison with the simulation results obtained from two particle-in-cell codes, which show good agreement.

  19. Fiber-optic detector for real time dosimetry of a micro-planar x-ray beam

    PubMed Central

    Belley, Matthew D.; Stanton, Ian N.; Hadsell, Mike; Ger, Rachel; Langloss, Brian W.; Lu, Jianping; Zhou, Otto; Chang, Sha X.; Therien, Michael J.; Yoshizumi, Terry T.

    2015-01-01

    Purpose: Here, the authors describe a dosimetry measurement technique for microbeam radiation therapy using a nanoparticle-terminated fiber-optic dosimeter (nano-FOD). Methods: The nano-FOD was placed in the center of a 2 cm diameter mouse phantom to measure the deep tissue dose and lateral beam profile of a planar x-ray microbeam. Results: The continuous dose rate at the x-ray microbeam peak measured with the nano-FOD was 1.91 ± 0.06 cGy s−1, a value 2.7% higher than that determined via radiochromic film measurements (1.86 ± 0.15 cGy s−1). The nano-FOD-determined lateral beam full-width half max value of 420 μm exceeded that measured using radiochromic film (320 μm). Due to the 8° angle of the collimated microbeam and resulting volumetric effects within the scintillator, the profile measurements reported here are estimated to achieve a resolution of ∼0.1 mm; however, for a beam angle of 0°, the theoretical resolution would approach the thickness of the scintillator (∼0.01 mm). Conclusions: This work provides proof-of-concept data and demonstrates that the novel nano-FOD device can be used to perform real-time dosimetry in microbeam radiation therapy to measure the continuous dose rate at the x-ray microbeam peak as well as the lateral beam shape. PMID:25832087

  20. Palm-top size X-ray microanalyzer using a pyroelectric focused electron beam with 100-micro-meter diameter

    NASA Astrophysics Data System (ADS)

    Kawai, Jun; Ohtani, Issei; Imanishi, Akira; Imashuku, Susumu

    2014-04-01

    We have developed a palm-top size EPMA (electron probe X-ray microanalyzer), operated by 3 V electric battery except for a rotary vacuum pump. The electron beam was generated by a pyroelectric single crystal, LiTaO3. A needle was used to make a focused electron beam. The smallest beam size was 100 μm on the sample surface. The X-ray spectra were measured through a Kapton window by a Si-PIN detector for a model specimen containing TiO2 and MnO2 particles, which was an aerosol model specimen, where TiO2 and MnO2 particles of size about 100-200 μm were separated by a few hundreds micrometers. By moving the sample stage manually, the X-ray spectra were measured for 300 s each by 300 μm e-beam, and the measured X-ray intensities were strong enough for identification of the major element in individual 100-200 μm size aerosol particles.

  1. The Influence of Neutral Beam Injection on the Heating and Current Drive with Electron Cyclotron Wave on EAST

    NASA Astrophysics Data System (ADS)

    Chang, Pengxiang; Wu, Bin; Wang, Jinfang; Li, Yingying; Wang, Xiaoguang; Xu, Handong; Wang, Xiaojie; Liu, Yong; Zhao, Hailin; Hao, Baolong; Yang, Zhen; Zheng, Ting; Hu, Chundong

    2016-11-01

    Both neutral beam injection (NBI) and electron cyclotron resonance heating (ECRH) have been applied on the Experimental Advanced Superconducting Tokamak (EAST) in the 2015 campaign. In order to achieve more effective heating and current drive, the effects of NBI on the heating and current drive with electron cyclotron wave (ECW) are analyzed utilizing the code TORAY and experimental data in the shot #54411 and #54417. According to the experimental and simulated results, for the heating with ECW, NBI can improve the heating efficiency and move the power deposition place towards the inside of the plasma. On the other hand, for the electron cyclotron current drive (ECCD), NBI can also improve the efficiency of ECCD and move the place of ECCD inward. These results will be valuable for the center heating, the achievement of fully non-inductive current drive operation and the suppression of magnetohydrodynamic (MHD) instabilities with ECW on EAST or ITER with many auxiliary heating methods. supported by the National Magnetic Confinement Fusion Science Program of China (Nos. 2013GB101001 and 2014DFG61950) and National Natural Science Foundation of China (Nos. 11405212 and 11175211)

  2. Characterization of plasma ion source utilizing anode spot with positively biased electrode for stable and high-current ion beam extraction

    SciTech Connect

    Park, Yeong-Shin; Lee, Yuna; Chung, Kyoung-Jae; Hwang, Y. S.

    2011-12-15

    The operating conditions of a rf plasma ion source utilizing a positively biased electrode have been investigated to develop a stably operating, high-current ion source. Ion beam characteristics such as currents and energies are measured and compared with bias currents by varying the bias voltages on the electrode immersed in the ambient rf plasma. Current-voltage curves of the bias electrode and photographs confirm that a small and dense plasma, so-called anode spot, is formed near an extraction aperture and plays a key role to enhance the performance of the plasma ion source. The ion beam currents from the anode spot are observed to be maximized at the optimum bias voltage near the knee of the characteristic current-voltage curve of the anode spot. Increased potential barrier to obstruct beam extraction is the reason for the reduction of the ion beam current in spite of the increased bias current indicating the density of the anode spot. The optimum bias voltage is measured to be lower at higher operating pressure, which is favorable for stable operation without severe sputtering damage on the electrode. The ion beam current can be further enhanced by increasing the power for the ambient plasma without increasing the bias voltage. In the same manner, noble gases with higher atomic number as a feedstock gas are preferable for extracting higher beam current more stably. Therefore, performance of the plasma ion source with a positively biased electrode can be enhanced by controlling the operating conditions of the anode spot in various manners.

  3. Electron beam induced current study of minority carrier diffusion length in homoepitaxial GaN (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Talin, A. Alec; Collins, Kimberlee C.; Armstrong, Andrew M.; Allerman, Andrew A.; Léonard, François

    2016-09-01

    GaN is a promising material for a range of high power, high frequency, and high temperature device applications. The wide bandgap of GaN leads to high breakdown voltages and low switching losses. Recently, large HVPE grown GaN substrates have become available for homoepitaxial growth leading to 103 reduction in dislocation density compared to similarly grown heteroepitaxial films. Device performance, however, is ultimately limited by the transport properties of minority carriers. Measured values for minority carrier diffusion lengths and lifetimes in GaN vary widely1-3, and a recent report suggests flaws in the commonly adopted electron beam induced current (EBIC) method in the planar-collection geometry.1 Here we report on EBIC measurements performed on 8 micrometer thick GaN grown by MOCVD on 2 inch GaN substrates with a n-type dopant density of 5×1016 cm-3. We determine the carrier diffusion length using both the conventional EBIC method by varying the electron beam-to-contact lateral distance as well as by varying the electron beam penetration depth and find the extracted values differ by 10×, with the latter technique yielding the lower diffusion length. We rationalize these results in light of other materials characteristics including Raman and photoluminescence. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000.

  4. Micro-unmanned aerodynamic vehicle

    SciTech Connect

    Reuel, Nigel; Lionberger, Troy A.; Galambos, Paul C.; Okandan, Murat; Baker, Michael S.

    2008-03-11

    A MEMS-based micro-unmanned vehicle includes at least a pair of wings having leading wing beams and trailing wing beams, at least two actuators, a leading actuator beam coupled to the leading wing beams, a trailing actuator beam coupled to the trailing wing beams, a vehicle body having a plurality of fulcrums pivotally securing the leading wing beams, the trailing wing beams, the leading actuator beam and the trailing actuator beam and having at least one anisotropically etched recess to accommodate a lever-fulcrum motion of the coupled beams, and a power source.

  5. Simulation of ion beam induced current in radiation detectors and microelectronic devices.

    SciTech Connect

    Vizkelethy, Gyorgy

    2009-10-01

    Ionizing radiation is known to cause Single Event Effects (SEE) in a variety of electronic devices. The mechanism that leads to these SEEs is current induced by the radiation in these devices. While this phenomenon is detrimental in ICs, this is the basic mechanism behind the operation of semiconductor radiation detectors. To be able to predict SEEs in ICs and detector responses we need to be able to simulate the radiation induced current as the function of time. There are analytical models, which work for very simple detector configurations, but fail for anything more complex. On the other end, TCAD programs can simulate this process in microelectronic devices, but these TCAD codes costs hundreds of thousands of dollars and they require huge computing resources. In addition, in certain cases they fail to predict the correct behavior. A simulation model based on the Gunn theorem was developed and used with the COMSOL Multiphysics framework.

  6. Simulation of ion beam induced current in radiation detectors and microelectronic devices.

    SciTech Connect

    Vizkelethy, Gyorgy

    2010-07-01

    Ionizing radiation is known to cause Single Event Effects (SEE) in a variety of electronic devices. The mechanism that leads to these SEEs is current induced by the radiation in these devices. While this phenomenon is detrimental in ICs, this is the basic mechanism behind the operation of semiconductor radiation detectors. To be able to predict SEEs in ICs and detector responses we need to be able to simulate the radiation induced current as the function of time. There are analytical models, which work for very simple detector configurations, but fail for anything more complex. On the other end, TCAD programs can simulate this process in microelectronic devices, but these TCAD codes costs hundreds of thousands of dollars and they require huge computing resources. In addition, in certain cases they fail to predict the correct behavior. A simulation model based on the Gunn theorem was developed and used with the COMSOL Multiphysics framework.

  7. 5-HT induces cAMP production in crypt colonocytes at a 5-HT4 receptor.

    PubMed

    Albuquerque, F C; Smith, E H; Kellum, J M

    1998-07-01

    Previous studies demonstrate that both 5-hydroxytryptamine (5-HT) and cyclic AMP (cAMP) induce chloride efflux from crypt colonocytes in the rat distal colon; antagonist studies suggest that the 5-HT response is mediated primarily by the 5-HT4 receptor. Since this receptor is known to be positively coupled to adenylate cyclase, we postulated that 5-HT should induce generation of cAMP, which should be inhibited by 5-HT4 antagonists. Method. Mucosal cells from rat distal colon were taken by a sequential calcium chelation technique for enrichment of crypt cells. Cytokeratin stains demonstrated that >99% of cells were colonocytes. [3H]Thymidine uptake studies demonstrate a fivefold increased incorporation in this cell preparation compared to earlier fractions. 3-Isobutyl-l-methylxanthine (IBMX, 100 microM) was added to all cell suspensions in order to prevent cAMP metabolism. Cell suspensions were incubated for 2 min at 37 degreesC with different concentrations of 5-HT (n = 7). cAMP was measured by enzyme immunoassay. In another series of experiments, 5-HT (0.3 microM) stimulation of cAMP was similarly measured in the presence and absence of 5-HT receptor antagonists: 10 microM 5-HTP-DP (5-HT1P; n = 4), 0.1 microM ketanserin (5-HT2A; n = 4), 0.3 microM ondansetron (5-HT3; n = 4), 3 microM tropisetron (5-HT3 and 5-HT4; n = 4), and 10 nM GR-113808 (5-HT4; n = 5). Results. 5-HT produced a dose-dependent increase in cAMP. The increase was significant at concentrations >/=0.3 microM when compared to cells incubated with IBMX alone. In the second series of experiment, 5-HT-induced generation of cAMP at a dose of 0.3 microM was significantly inhibited in the presence of GR-113808 and tropisetron. Conclusion. 5-HT acts at a 5-HT4 receptor to induce production of cAMP in rat distal crypt colonocytes.

  8. Influence of 700 °C vacuum annealing on fracture behavior of micro/nanoscale focused ion beam fabricated silicon structures

    NASA Astrophysics Data System (ADS)

    Goshima, Yoshiharu; Fujii, Tatsuya; Inoue, Shozo; Namazu, Takahiro

    2016-06-01

    In this paper, we describe the influence of 700 °C vacuum annealing on strength and fracture behavior of micro- and nano-scale Si structures fabricated by focused ion beam (FIB). Si nanowires (NWs) made from silicon-on-nothing (SON) membrane are fabricated using FIB. Microscale Si specimens are fabricated by conventional micromachining technologies and FIB. These specimens are tensioned to failure using specially developed microelectromechanical systems (MEMS) device and thin-film tensile tester, respectively. The mean fracture strengths of the nano- and microscale specimens are 5.6 and 1.6 GPa, respectively, which decrease to 2.9 and 0.9 GPa after vacuum annealing at 700 °C for only 10 s. These strength values do not vary with increasing annealing time. Fracture origin and its behavior are discussed in the light of fracture surface and FIB damage layer observations.

  9. [Stimulation of longitudinal growth of long bones through electrical current. Scintigraphic examinations on ribbit tibiae].

    PubMed

    Klems, H; Venohr, H; Weigert, M

    1975-01-01

    Report on szintigraphical examinations using 87-mSr in young rabbits treated by direct current of different intensity varying from 2.5 to 40 micro-Ampère. The current was applicated to one tibia using the other as comparison. Corresponding to the realised growth-increase by electric stimulation there was found an increased uptake of 87m-Sr in the electro-stimulated tibia in all 16 rabbits.

  10. The Protein Micro-Crystallography Beamlines for Targeted Protein Research Program

    NASA Astrophysics Data System (ADS)

    Hirata, Kunio; Yamamoto, Masaki; Matsugaki, Naohiro; Wakatsuki, Soichi

    In order to collect proper diffraction data from outstanding micro-crystals, a brand-new data collection system should be designed to provide high signal-to noise ratio in diffraction images. SPring-8 and KEK-PF are currently developing two micro-beam beamlines for Targeted Proteins Research Program by MEXT of Japan. The program aims to reveal the structure and function of proteins that are difficult to solve but have great importance in both academic research and industrial application. At SPring-8, a new 1-micron beam beamline for protein micro-crystallography, RIKEN Targeted Proteins Beamline (BL32XU), is developed. At KEK-PF a new low energy micro-beam beamline, BL-1A, is dedicated for SAD micro-crystallography. The two beamlines will start operation in the end of 2010. The present status of the research and development for protein micro-crystallography will be presented.

  11. Beam and spin dynamics in the fast ramping storage ring ELSA: Concepts and measures to increase beam energy, current and polarization

    NASA Astrophysics Data System (ADS)

    Hillert, Wolfgang; Balling, Andreas; Boldt, Oliver; Dieckmann, Andreas; Eberhardt, Maren; Frommberger, Frank; Heiliger, Dominik; Heurich, Nikolas; Koop, Rebecca; Klarner, Fabian; Preisner, Oliver; Proft, Dennis; Pusch, Thorsten; Roth, André; Sauerland, Dennis; Schedler, Manuel; Schmidt, Jan Felix; Switka, Michael; Thiry, Jens-Peter; Wittschen, Jürgen; Zander, Sven

    2017-01-01

    The electron accelerator facility ELSA has been operated for almost 30 years serving nuclear physics experiments investigating the sub-nuclear structure of matter. Within the 12 years funding period of the collaborative research center SFB/TR 16, linearly and circularly polarized photon beams with energies up to more than 3 GeV were successfully delivered to photoproduction experiments. In order to fulfill the increasing demands on beam polarization and intensity, a comprehensive research and upgrade program has been carried out. Beam and spin dynamics have been studied theoretically and experimentally, and sophisticated new devices have been developed and installed. The improvements led to a significant increase of the available beam polarization and intensity. A further increase of beam energy seems feasible with the implementation of superconducting cavities.

  12. Optical beam induced current measurements based on two-photon absorption process in 4H-SiC bipolar diodes

    SciTech Connect

    Hamad, H.; Raynaud, C.; Bevilacqua, P.; Tournier, D.; Planson, D.; Vergne, B.

    2014-02-24

    Using a pulsed green laser with a wavelength of 532 nm, a duration pulse of ∼1 ns, and a mean power varying between 1 and 100 mW, induced photocurrents have been measured in 4H-SiC bipolar diodes. Considering the photon energy (2.33 eV) and the bandgap of 4H-SiC (3.2 eV), the generation of electron-hole pair by the conventional single photon absorption process should be negligible. The intensity of the measured photocurrents depends quadratically on the power beam intensity. This clearly shows that they are generated using two-photon absorption process. As in conventional OBIC (Optical Beam Induced Current), the measurements give an image of the electric field distribution in the structure under test, and the minority carrier lifetime can be extracted from the decrease of the photocurrent at the edge of the structure. The extracted minority carrier lifetime of 210 ns is consistent with results obtained in case of single photon absorption.

  13. Current instabilities in dynamic random access memory storage capacitor formed with electron beam deposited Y2O3 dielectric

    NASA Astrophysics Data System (ADS)

    Rastogi, A. C.; Sharma, R. N.

    Metal-oxide-semiconductor (MOS) storage capacitors based on electron beam deposited Y2O3 extrinsic dielectric on Si show changes in capacitance density depending on the amorphous and crystalline phases. Bias stress cycle-dependent changes in capacitance density occur due to the non-equilibrium nature of defect states at the Y2O3/Si interface after O2 annealing as a result of the emergence of a 4-8 nm thick SiO2 film at the interface. Leakage currents show instability under repeated dc bias stress, the nature and extent of which depend upon the structure of the Y2O3 gate dielectric and the polarity of dc bias. With amorphous Y2O3, leakage currents drift to lower values under gate injection due to electron trapping, and to higher values under Si-injection due to the generation of holes. Though leakage current drift is minimal for crystalline Y2O3, its magnitude increases as the energy of injected electrons from mid-gap states is low and the local field due to asperity is high. The emergence of interfacial SiO2 reduces the magnitude of Si-injection leakage current substantially, but causes transient changes resulting in switching to higher values at a threshold dc bias. Thermal detrapping of holes and reverse bias stress studies confirm that the instability of current is caused by an increase in the cathodic field from hole trapping at interface states. Leakage current instability limits the application of extrinsic high dielectric constant dielectrics in a high density DRAM storage capacitor, unless a new interface layer scheme other than SiO2 and a method to form a defect-free dielectric layer can be implemented.

  14. Imaging interfacial electrical transport in graphene–MoS{sub 2} heterostructures with electron-beam-induced-currents

    SciTech Connect

    White, E. R. Kerelsky, Alexander; Hubbard, William A.; Regan, B. C.; Dhall, Rohan; Cronin, Stephen B.; Mecklenburg, Matthew

    2015-11-30

    Heterostructure devices with specific and extraordinary properties can be fabricated by stacking two-dimensional crystals. Cleanliness at the inter-crystal interfaces within a heterostructure is crucial for maximizing device performance. However, because these interfaces are buried, characterizing their impact on device function is challenging. Here, we show that electron-beam induced current (EBIC) mapping can be used to image interfacial contamination and to characterize the quality of buried heterostructure interfaces with nanometer-scale spatial resolution. We applied EBIC and photocurrent imaging to map photo-sensitive graphene-MoS{sub 2} heterostructures. The EBIC maps, together with concurrently acquired scanning transmission electron microscopy images, reveal how a device's photocurrent collection efficiency is adversely affected by nanoscale debris invisible to optical-resolution photocurrent mapping.

  15. Dose and Chemical Modification Considerations for Continuous Cyclic AMP Analog Delivery to the Injured CNS

    PubMed Central

    Fouad, Karim; Ghosh, Mousumi; Vavrek, Romana; Tse, Arthur D.

    2009-01-01

    Abstract In this investigation, two cell-permeable synthetic analogs of cAMP, dibutyryl-cAMP (db-cAMP) and 8-bromo-cAMP, which are widely used to elevate intracellular cAMP levels under experimental conditions, were investigated for their ability to dose-dependently improve histological and functional outcomes following continuous delivery in two models of incomplete spinal cord injury (SCI). The cAMP analogs were delivered via osmotic minipumps at 1–250 mM through an indwelling cortical cannula or by intrathecal infusion for up to 4 weeks after either a T8 unilateral over-hemisection or a C2-3 dorsolateral quadrant lesion, respectively. In both SCI models, continuous db-cAMP delivery was associated with histopathological changes that included sporadic micro-hemorrhage formation and cavitation, enhanced macrophage infiltration and tissue damage at regions beyond the immediate application site; no deleterious or beneficial effect of agent delivery was observed at the spinal injury site. Furthermore, these changes were accompanied by pronounced behavioral deficits that included an absence of progressive locomotor recovery, increased extensor tone, paralysis, and sensory abnormalities. These deleterious effects were not observed in saline-treated animals, in animals in which the db-cAMP dose did not exceed 1 mM, or in those animals that received a high dose (250 mM) of the alternative cAMP analog, 8-bromo-cAMP. These results demonstrate that, for continuous intraparenchymal or intrathecal administration of cAMP analogs for the study of biological or therapeutic effects within the central nervous system (CNS), consideration of the effective concentration applied as well as the potential toxicity of chemical moieties on the parent molecule and/or their activity needs to be taken into account. PMID:19397425

  16. Fiber-optic detector for real time dosimetry of a micro-planar x-ray beam

    SciTech Connect

    Belley, Matthew D.; Stanton, Ian N.; Langloss, Brian W.; Therien, Michael J.; Hadsell, Mike; Ger, Rachel; Lu, Jianping; Zhou, Otto; Chang, Sha X.; Yoshizumi, Terry T.

    2015-04-15

    Purpose: Here, the authors describe a dosimetry measurement technique for microbeam radiation therapy using a nanoparticle-terminated fiber-optic dosimeter (nano-FOD). Methods: The nano-FOD was placed in the center of a 2 cm diameter mouse phantom to measure the deep tissue dose and lateral beam profile of a planar x-ray microbeam. Results: The continuous dose rate at the x-ray microbeam peak measured with the nano-FOD was 1.91 ± 0.06 cGy s{sup −1}, a value 2.7% higher than that determined via radiochromic film measurements (1.86 ± 0.15 cGy s{sup −1}). The nano-FOD-determined lateral beam full-width half max value of 420 μm exceeded that measured using radiochromic film (320 μm). Due to the 8° angle of the collimated microbeam and resulting volumetric effects within the scintillator, the profile measurements reported here are estimated to achieve a resolution of ∼0.1 mm; however, for a beam angle of 0°, the theoretical resolution would approach the thickness of the scintillator (∼0.01 mm). Conclusions: This work provides proof-of-concept data and demonstrates that the novel nano-FOD device can be used to perform real-time dosimetry in microbeam radiation therapy to measure the continuous dose rate at the x-ray microbeam peak as well as the lateral beam shape.

  17. AKAP-mediated feedback control of cAMP gradients in developing hippocampal neurons.

    PubMed

    Gorshkov, Kirill; Mehta, Sohum; Ramamurthy, Santosh; Ronnett, Gabriele V; Zhou, Feng-Quan; Zhang, Jin

    2017-04-01

    Cyclic AMP (cAMP) and protein kinase A (PKA), classical examples of spatially compartmentalized signaling molecules, are critical axon determinants that regulate neuronal polarity and axon formation, yet little is known about micro-compartmentalization of cAMP and PKA signaling and its role in developing neurons. Here, we revealed that cAMP forms a gradient in developing hippocampal neurons, with higher cAMP levels in more distal regions of the axon compared to other regions of the cell. Interestingly, this cAMP gradient changed according to the developmental stage and depended on proper anchoring of PKA by A-kinase anchoring proteins (AKAPs). Disrupting PKA anchoring to AKAPs increased the cAMP gradient in early-stage neurons and led to enhanced axon elongation. Our results provide new evidence for a local negative-feedback loop, assembled by AKAPs, for the precise control of a growth-stage-dependent cAMP gradient to ensure proper axon growth.

  18. LEDA BEAM DIAGNOSTICS INSTRUMENTATION: BEAM POSITION MONITORS

    SciTech Connect

    D. BARR; ET AL

    2000-05-01

    The Low Energy Demonstration Accelerator (LEDA) facility located at Los Alamos National Laboratory (LANL) accelerates protons to an energy of 6.7-MeV and current of 100-mA operating in either a pulsed or cw mode. Of key importance to the commissioning and operations effort is the Beam Position Monitor system (BPM). The LEDA BPM system uses five micro-stripline beam position monitors processed by log ratio processing electronics with data acquisition via a series of custom TMS32OC40 Digital Signal Processing (DSP) boards. Of special interest to this paper is the operation of the system, the log ratio processing, and the system calibration technique. This paper will also cover the DSP system operations and their interaction with the main accelerator control system.

  19. Influence of electron-beam lithography exposure current level on the transport characteristics of graphene field effect transistors

    NASA Astrophysics Data System (ADS)

    Kang, Sangwoo; Movva, Hema C. P.; Sanne, Atresh; Rai, Amritesh; Banerjee, Sanjay K.

    2016-03-01

    Many factors have been identified to influence the electrical transport characteristics of graphene field-effect transistors. In this report, we examine the influence of the exposure current level used during electron beam lithography (EBL) for active region patterning. In the presence of a self-assembled hydrophobic residual layer generated by oxygen plasma etching covering the top surface of the graphene channel, we show that the use of low EBL current level results in higher mobility, lower residual carrier density, and charge neutrality point closer to 0 V, with reduced device-to-device variations. We show that this correlation originates from the resist heating dependent release of radicals from the resist material, near its interface with graphene, and its subsequent trapping by the hydrophobic polymer layer. Using a general model for resist heating, we calculate the difference in resist heating for different EBL current levels. We further corroborate our argument through control experiments, where radicals are either intentionally added or removed by other processes. We also utilize this finding to obtain mobilities in excess of 18 000 cm2/V s on silicon dioxide substrates. We believe these results are applicable to other 2D materials such as transition metal dichalcogenides and nanoscale devices in general.

  20. Hierarchical micro-lamella-structured 3D porous copper current collector coated with tin for advanced lithium-ion batteries

    NASA Astrophysics Data System (ADS)

    Park, Hyeji; Um, Ji Hyun; Choi, Hyelim; Yoon, Won-Sub; Sung, Yung-Eun; Choe, Heeman

    2017-03-01

    A Novel 3D porous Sn-Cu architecture is prepared as an anode material for use in an advanced lithium-ion battery. Micro-lamellar-structured 3D porous Cu foam, which is electroless-plated with Sn as an active material, is used as anode current collector. Compared to Sn-coated Cu foil, the 3D Sn-Cu foam exhibits superior Li-ion capacity and stable capacity retention, demonstrating the advantage of 3D porous architecture by preserving its structural integrity. In addition, the effect of heat-treatment after Sn plating is investigated. Sn/Sn6Cu5 and SnO2/Cu10Sn3 were formed on and in the 3D Sn-Cu foam under the heat-treatment at 150 °C and 500 °C, respectively. The development of Cu10Sn3 in the 3D Sn-Cu foam heat-treated at 500 °C can be a key factor for the enhanced cyclic stability because the Cu10Sn3 inactively reacts with Li-ion and alleviates the volume expansion of SnO2 as an inactive matrix.