Steward, Christine D.; Stocker, Sheila A.; Swenson, Jana M.; O’Hara, Caroline M.; Edwards, Jonathan R.; Gaynes, Robert P.; McGowan, John E.; Tenover, Fred C.
1999-01-01
Fluoroquinolone resistance appears to be increasing in many species of bacteria, particularly in those causing nosocomial infections. However, the accuracy of some antimicrobial susceptibility testing methods for detecting fluoroquinolone resistance remains uncertain. Therefore, we compared the accuracy of the results of agar dilution, disk diffusion, MicroScan Walk Away Neg Combo 15 conventional panels, and Vitek GNS-F7 cards to the accuracy of the results of the broth microdilution reference method for detection of ciprofloxacin and ofloxacin resistance in 195 clinical isolates of the family Enterobacteriaceae collected from six U.S. hospitals for a national surveillance project (Project ICARE [Intensive Care Antimicrobial Resistance Epidemiology]). For ciprofloxacin, very major error rates were 0% (disk diffusion and MicroScan), 0.9% (agar dilution), and 2.7% (Vitek), while major error rates ranged from 0% (agar dilution) to 3.7% (MicroScan and Vitek). Minor error rates ranged from 12.3% (agar dilution) to 20.5% (MicroScan). For ofloxacin, no very major errors were observed, and major errors were noted only with MicroScan (3.7% major error rate). Minor error rates ranged from 8.2% (agar dilution) to 18.5% (Vitek). Minor errors for all methods were substantially reduced when results with MICs within ±1 dilution of the broth microdilution reference MIC were excluded from analysis. However, the high number of minor errors by all test systems remains a concern. PMID:9986809
Genotoxicity of mercury used in chromosome aberration tests.
Akiyama, M; Oshima, H; Nakamura, M
2001-01-01
The purpose of this study was to investigate the genotoxic effects of Hg released from dental amalgams. The chromosome aberration test was conducted using original extracts and their diluted solutions of conventional type amalgam and high copper amalgam. The concentrations of Hg, Cu and Ag in the original extract of high copper amalgam were 17.64, 7.97 and 43.90 microM, respectively. Those in the original extract of conventional type amalgam were 20.63, 7.87 and 14.79 microM, respectively. 10 and 30 microM Hg(2+) were also used for comparison. The frequency of chromosome aberrations was below 5% with 0 microM Hg(2+) and with a triple dilution of high copper amalgam extract, containing 5.88 microM Hg, 14.63 microM Cu and 2.65 microM Ag. However, 9.5% of the cells showed chromosome aberrations with a quadruple dilution of conventional type amalgam, containing 5.15 microM Hg, 3.69 microM Cu and 1.96 microM Ag. The amount of Hg in the quadruple dilution of conventional type amalgam was less than that in the triple dilution of high copper amalgam extract and 10 microM Hg(2+). A concentration of 30 microM Hg(2+) caused 34.5% of the cells to show chromosome aberrations while with a two-thirds dilution of high copper amalgam extract, containing 11.76 microM Hg, 29.26 microM Cu and 5.31 microM Ag, 58.5% of the cells showed chromosome aberrations. A two-thirds dilution of high copper amalgam extract induced more chromosome aberrations than 30 microM Hg(2+), although the amount of Hg was less than 30 microM Hg(2+). A triple dilution of conventional type amalgam extract, original extracts of conventional type amalgam and high copper amalgam and 100 microM Hg(2+) were induced few metaphases. It was revealed that the conventional type amalgam induced chromosome aberrations with quadruple dilution where cell viability was about 80% and that the high copper amalgam induced a high level of chromosome aberrations with the two-thirds dilution. The effects of low level Hg on humans are not clear.
Thomas, Pious; Sekhar, Aparna C; Upreti, Reshmi; Mujawar, Mohammad M; Pasha, Sadiq S
2015-12-01
We propose a simple technique for bacterial and yeast cfu estimations from diverse samples with no prior idea of viable counts, designated as single plate-serial dilution spotting (SP-SDS) with the prime recommendation of sample anchoring (10 0 stocks). For pure cultures, serial dilutions were prepared from 0.1 OD (10 0 ) stock and 20 μl aliquots of six dilutions (10 1 -10 6 ) were applied as 10-15 micro-drops in six sectors over agar-gelled medium in 9-cm plates. For liquid samples 10 0 -10 5 dilutions, and for colloidal suspensions and solid samples (10% w/v), 10 1 -10 6 dilutions were used. Following incubation, at least one dilution level yielded 6-60 cfu per sector comparable to the standard method involving 100 μl samples. Tested on diverse bacteria, composite samples and Saccharomyces cerevisiae , SP-SDS offered wider applicability over alternative methods like drop-plating and track-dilution for cfu estimation, single colony isolation and culture purity testing, particularly suiting low resource settings.
Márta, Zoltán; Bobály, Balázs; Fekete, Jenő; Magda, Balázs; Imre, Tímea; Mészáros, Katalin Viola; Szabó, Pál Tamás
2016-09-10
Ultratrace analysis of sample components requires excellent analytical performance in terms of limits of quantitation (LoQ). Micro UHPLC coupling with sensitive tandem mass spectrometry provides state of the art solutions for such analytical problems. Decreased column volume in micro LC limits the injectable sample volume. However, if analyte concentration is extremely low, it might be necessary to inject high sample volumes. This is particularly critical for strong sample solvents and weakly retained analytes, which are often the case when preparing biological samples (protein precipitation, sample extraction, etc.). In that case, high injection volumes may cause band broadening, peak distortion or even elution in dead volume. In this study, we evaluated possibilities of high volume injection onto microbore RP-LC columns, when sample solvent is diluted. The presented micro RP-LC-MS/MS method was optimized for the analysis of steroid hormones from human plasma after protein precipitation with organic solvents. A proper sample dilution procedure helps to increase the injection volume without compromising peak shapes. Finally, due to increased injection volume, the limit of quantitation can be decreased by a factor of 2-5, depending on the analytes and the experimental conditions. Copyright © 2016 Elsevier B.V. All rights reserved.
High-throughput method to predict extrusion pressure of ceramic pastes.
Cao, Kevin; Liu, Yang; Tucker, Christopher; Baumann, Michael; Grit, Grote; Lakso, Steven
2014-04-14
A new method was developed to measure the rheology of extrudable ceramic pastes using a Hamilton MicroLab Star liquid handler. The Hamilton instrument, normally used for high throughput liquid processing, was expanded to function as a low pressure capillary rheometer. Diluted ceramic pastes were forced through the modified pipettes, which produced pressure drop data that was converted to standard rheology data. A known ceramic paste containing cellulose ether was made and diluted to various concentrations in water. The most dilute paste samples were tested in the Hamilton instrument and the more typical, highly concentrated, ceramic paste were tested with a hydraulic ram extruder fitted with a capillary die and pressure measurement system. The rheology data from this study indicates that the dilute high throughput method using the Hamilton instrument correlates to, and can predict, the rheology of concentrated ceramic pastes normally used in ceramic extrusion production processes.
Chen, Ben; Tian, Xiaofei; Yu, Lian; Wu, Zhenqiang
2016-12-01
Pigments in molasses wastewater (MWW) effluent, such as melanoidins, were considered as kinds of the most recalcitrant and hazardous colorant contaminants to the environment. In this study, de-coloring the MWW by a synergistic combination of micro-electrolysis with bio-treatment was performed. Aiming to a high de-colorization yield, levels of nutrition source supplies, MWW dilution ratio, and micro-electrolysis reaction time were optimized accordingly. For a diluted (50 %, v/v) MWW, an maximum overall de-colorization yield (97.1 ± 0.5 %, for absorbance at 475 nm) was achieved through the bio-electrolysis treatment. In electrolysis bio-treatment, the positive effect of micro-electrolysis was also revealed by a promoted growth of fungal biomass as well as activities of ligninolytic enzymes. Activities of lignin peroxidase, manganese peroxidase, and laccase were promoted by 111.2, 103.9, and 7.7 %, respectively. This study also implied that the bio-treatment and the micro-electrolysis had different efficiencies on removal of pigments with distinct polarities.
Park, Jong-Ho; Choi, Eun-Ju
2016-11-01
A method to determine the quantity and isotopic ratios of uranium in individual micro-particles simultaneously by isotope dilution thermal ionization mass spectrometry (ID-TIMS) has been developed. This method consists of sequential sample and spike loading, ID-TIMS for isotopic measurement, and application of a series of mathematical procedures to remove the contribution of uranium in the spike. The homogeneity of evaporation and ionization of uranium content was confirmed by the consistent ratio of n((233)U)/n((238)U) determined by TIMS measurements. Verification of the method was performed using U030 solution droplets and U030 particles. Good agreements of resulting uranium quantity, n((235)U)/n((238)U), and n((236)U)/n((238)U) with the estimated or certified values showed the validity of this newly developed method for particle analysis when simultaneous determination of the quantity and isotopic ratios of uranium is required. Copyright © 2016 Elsevier B.V. All rights reserved.
Finck, Rachel; Lui-Deguzman, Carrie; Teng, Shih-Mao; Davis, Rebecca; Yuan, Shan
2013-04-01
Titration is a semiquantitative method used to estimate red blood cell (RBC) alloantibody reactivity. The conventional tube test (CTT) technique is the traditional method for performing titration studies. The gel microcolumn assay (GMA) is also a sensitive method to detect RBC alloantibodies. The aim of this study was to compare a GMA with the CTT technique in the performance of Rh and K alloantibody titration. Patient serum samples that contained an RBC alloantibody with a singular specificity were identified by routine blood bank workflow. Parallel titration studies were performed on these samples by both the CTT method and a GMA (ID-Micro Typing System anti-IgG gel card, Micro Typing Systems, Inc., an Ortho-Clinical Diagnostics Company). Forty-eight samples were included, including 11 anti-D, five anti-c, 13 anti-E, one anti-C, three anti-e, and 15 anti-K. Overall, the two methods generated identical results in 21 of 48 samples. For 42 samples (87.5%) the two methods generated results that were within one serial dilution, and for the remaining six samples, results were within two dilutions. GMA systems may perform comparably to the CTT in titrating alloantibodies to Rh and Kell antigens. © 2012 American Association of Blood Banks.
[Predation of micro-protozoa on bacteria in Taihu Lake].
Chen, Mo; Gao, Guang; Zhu, Li-Ping; Feng, Sheng
2007-10-01
With dilution method, this paper studied the predation of different size micro-protozoa on bacteria in Taihu Lake, and approached the effects of the predation on bacterial growth and of the water temperature on the predation. The results showed that in the water body of Taihu Lake, the predation rate of micro-protozoa with its size less than 32 microm was 5.07 d(-1), and the nano-size (less than 16 microm) protozoa contributed about 90.7%. The predation of nano-protozoa reduced the abundance of bacteria significantly. With the increase of water temperature, the predation rate of nano-protozoa and the growth rate of bacteria increased obviously.
Dubascoux, Stéphane; Andrey, Daniel; Vigo, Mario; Kastenmayer, Peter; Poitevin, Eric
2018-09-01
Nutritional information about human milk is essential as early human growth and development have been closely linked to the status and requirements of several macro- and micro-elements. However, methods addressing whole mineral profiling in human milk have been scarce due in part to their technical complexities to accurately and simultaneously measure the concentration of micro- and macro-trace elements in low volume of human milk. In the present study, a single laboratory validation has been performed using a "dilute and shoot" approach for the quantification of sodium (Na), magnesium (Mg), phosphorus (P), potassium (K), calcium (Ca), manganese (Mn), iron (Fe), copper (Cu), zinc (Zn), selenium (Se), molybdenum (Mo) and iodine (I), in both human milk and milk preparations. Performances in terms of limits of detection and quantification, of repeatability, reproducibility and trueness have been assessed and verified using various reference or certified materials. For certified human milk sample (NIST 1953), recoveries obtained for reference or spiked values are ranged from 93% to 108% (except for Mn at 151%). This robust method using new technology ICP-MS/MS without high pressure digestion is adapted to both routinely and rapidly analyze human milk micro-sample (i.e. less than 250 μL) in the frame of clinical trials but also to be extended to the mineral profiling of milk preparations like infant formula and adult nutritionals. Copyright © 2018 Elsevier GmbH. All rights reserved.
Ambers, Angie; Wiley, Rachel; Novroski, Nicole; Budowle, Bruce
2018-01-01
Previous studies have shown that nylon flocked swabs outperform traditional fiber swabs in DNA recovery due to their innovative design and lack of internal absorbent core to entrap cellular materials. The microFLOQ ® Direct swab, a miniaturized version of the 4N6 FLOQSwab ® , has a small swab head that is treated with a lysing agent which allows for direct amplification and DNA profiling from sample collection to final result in less than two hours. Additionally, the microFLOQ ® system subsamples only a minute portion of a stain and preserves the vast majority of the sample for subsequent testing or re-analysis, if desired. The efficacy of direct amplification of DNA from dilute bloodstains, saliva stains, and touch samples was evaluated using microFLOQ ® Direct swabs and the GlobalFiler™ Express system. Comparisons were made to traditional methods to assess the robustness of this alternate workflow. Controlled studies with 1:19 and 1:99 dilutions of bloodstains and saliva stains consistently yielded higher STR peak heights than standard methods with 1ng input DNA from the same samples. Touch samples from common items yielded single source and mixed profiles that were consistent with primary users of the objects. With this novel methodology/workflow, no sample loss occurs and therefore more template DNA is available during amplification. This approach may have important implications for analysis of low quantity and/or degraded samples that plague forensic casework. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.
Heilmann, Jens; Boulyga, Sergei F; Heumann, Klaus G
2004-09-01
Inductively coupled plasma isotope-dilution mass spectrometry (ICP-IDMS) with direct injection of isotope-diluted samples into the plasma, using a direct injection high-efficiency nebulizer (DIHEN), was applied for accurate sulfur determinations in sulfur-free premium gasoline, gas oil, diesel fuel, and heating oil. For direct injection a micro-emulsion consisting of the corresponding organic sample and an aqueous 34S-enriched spike solution with additions of tetrahydronaphthalene and Triton X-100, was prepared. The ICP-MS parameters were optimized with respect to high sulfur ion intensities, low mass-bias values, and high precision of 32S/34S ratio measurements. For validation of the DIHEN-ICP-IDMS method two certified gas oil reference materials (BCR 107 and BCR 672) were analyzed. For comparison a wet-chemical ICP-IDMS method was applied with microwave-assisted digestion using decomposition of samples in a closed quartz vessel inserted into a normal microwave system. The results from both ICP-IDMS methods agree well with the certified values of the reference materials and also with each other for analyses of other samples. However, the standard deviation of DIHEN-ICP-IDMS was about a factor of two higher (5-6% RSD at concentration levels above 100 mircog g(-1)) compared with those of wet-chemical ICP-IDMS, mainly due to inhomogeneities of the micro-emulsion, which causes additional plasma instabilities. Detection limits of 4 and 18 microg g(-1) were obtained for ICP-IDMS in connection with microwave-assisted digestion and DIHEN-ICP-IDMS, respectively, with a sulfur background of the used Milli-Q water as the main limiting factor for both methods.
Mann, G E; Yudilevich, D L
1984-01-01
Capillary permeability and cellular uptake of noradrenaline by the isolated artificially perfused rabbit heart was measured using rapid (less than 30 s) single-circulation tracer-dilution techniques. In a single coronary circulation capillary extractions of L-[14C]noradrenaline and D-[3H]mannitol (extracellular reference) relative to an intravascular marker, 125I-labelled albumin, were similar and above 60%. The 'apparent' volume of distribution for tracer noradrenaline was 2.5-fold larger than that measured for D-mannitol (0.32 ml g-1) suggesting cellular uptake of the amine. Unidirectional noradrenaline uptake was estimated by directly comparing coronary sinus dilution profiles of L-[3H]noradrenaline and D-[14C]mannitol. Michaelis-Menten saturation kinetics based on a single-entry system were determined (Km = 2.8 +/- 1.5 microM, Vmax = 2.1 +/- 0.5 nmol min-1 g-1, n = 4) by perfusing hearts with varying concentrations of L-noradrenaline (1-10 microM). Various known inhibitors of noradrenaline uptake were investigated to determine whether uptake was mediated by neuronal (uptake1) and/or extraneuronal (uptake2) mechanisms. Desipramine (5 microM), imipramine (5 microM) and metaraminol (2 microM) resulted in a 66-94% inhibition of noradrenaline influx. In comparison, the steroids, 17 beta-oestradiol (1 microM) and corticosterone (10 microM), and the noradrenaline metabolite normetanephrine (5 microM) caused virtually no inhibitory effects. The beta-adrenergic antagonist propranolol (5 microM) was also relatively ineffective. These results together with the kinetic constants estimated suggest that the rapid noradrenaline uptake reflects transport into adrenergic neurones lying in the coronary interstitium. The high resolution of this paired-tracer dilution technique has permitted a 'non-invasive' study of neuronal uptake mechanisms and its application may be of clinical value. PMID:6425496
Seely, R J; Fahrney, D E
1984-01-01
Batch-grown Methanobacterium thermoautotrophicum cells grew nonexponentially in the absence of exogenous Pi until intracellular cyclic-2,3-diphosphoglycerate (cyclic DPG) had fallen below 2 mumol/g (dry weight), the limit of detection. Growth resumed immediately upon transfer to medium containing Pi Cyclic DPG levels were also below detection in Pi-limited chemostat cultures operating at a dilution rate of 0.173 h-1 (4-h doubling time), with reservoir Pi concentrations below 200 microM. At this dilution rate, the Pi concentration in the culture was 4 microM. An H2-limited steady state was achieved with 400 microM Pi in the inflowing medium (67 microM in the culture). The cyclic DPG content of these cells was 72 to 74 mumol/g, about one-third the amount in batch-grown cells. The specific growth rate accelerated immediately to 0.36 h-1 (1.9-h doubling time) under washout conditions at high dilution rate. The cellular content of cyclic DPG declined over a 2-h period, and then increased rapidly as the Pi level in the medium approached 200 microM. Expansion of the cyclic DPG pool coincided with a marked increase in Pi assimilation. These results indicated that M. thermoautotrophicum accumulated cyclic DPG only when Pi and H2 were readily available. PMID:6480564
Seely, R J; Fahrney, D E
1984-10-01
Batch-grown Methanobacterium thermoautotrophicum cells grew nonexponentially in the absence of exogenous Pi until intracellular cyclic-2,3-diphosphoglycerate (cyclic DPG) had fallen below 2 mumol/g (dry weight), the limit of detection. Growth resumed immediately upon transfer to medium containing Pi Cyclic DPG levels were also below detection in Pi-limited chemostat cultures operating at a dilution rate of 0.173 h-1 (4-h doubling time), with reservoir Pi concentrations below 200 microM. At this dilution rate, the Pi concentration in the culture was 4 microM. An H2-limited steady state was achieved with 400 microM Pi in the inflowing medium (67 microM in the culture). The cyclic DPG content of these cells was 72 to 74 mumol/g, about one-third the amount in batch-grown cells. The specific growth rate accelerated immediately to 0.36 h-1 (1.9-h doubling time) under washout conditions at high dilution rate. The cellular content of cyclic DPG declined over a 2-h period, and then increased rapidly as the Pi level in the medium approached 200 microM. Expansion of the cyclic DPG pool coincided with a marked increase in Pi assimilation. These results indicated that M. thermoautotrophicum accumulated cyclic DPG only when Pi and H2 were readily available.
A novel 96-well gel-based assay for determining antifungal activity against filamentous fungi.
Troskie, Anscha Mari; Vlok, Nicolas Maré; Rautenbach, Marina
2012-12-01
In recent years the global rise in antibiotic resistance and environmental consciousness lead to a renewed fervour to find and develop novel antibiotics, including antifungals. However, the influence of the environment on antifungal activity is often disregarded and many in vitro assays may cause the activity of certain antifungals to be overestimated or underestimated. The general antifungal test assays that are economically accessible to the majority of scientists primarily rely on visual examination or on spectrophotometric analysis. The effect of certain morphogenic antifungals, which may lead to hyperbranching of filamentous fungi, unfortunately renders these methods unreliable. To minimise the difficulties experienced as a result of hyperbranching, we developed a straightforward, economical 96-well gel-based method, independent of spectrophotometric analysis, for highly repeatable determination of antifungal activity. For the calculation of inhibition parameters, this method relies on the visualisation of assay results by digitisation. The antifungal activity results from our novel micro-gel dilution assay are comparable to that of the micro-broth dilution assay used as standard reference test of The Clinical and Laboratory Standard Institute. Furthermore, our economical assay is multifunctional as it permits microscopic analysis of the preserved assay results, as well as rendering highly reliable data. Copyright © 2012 Elsevier B.V. All rights reserved.
[Counting colonies of micro-organisms on solid media (author's transl)].
Stonebrink, B
1978-11-01
The base of the system consists in a stainless steel cup with a shallow recess into which about 3 ml. of fluid agar medium may be poured, which produces a flat rectangular surface of about 8.65 sq. cm. after solidification. In the majority of cases, inoculation was performed by flooding the medium with a diluted suspension of micro-organisms. The cups were then put upright and carried over into a centrifuge tube which was closed with a rubber stopper. After the required incubation period, the colonies were counted, if necessary, using a specially developed colony counter connected to an electromechanical counting relay. Dilutions were prepared in screw capped bottles of various sizes. Pipettes were used only with connected "Volac" pipette holders. Cleaning and sterilisation could be done in an efficient and reliable way. In addition to the above method, the cups containing media may also be used for: impression counts, examination of fluids by immersion, inoculation by swabs or wire loops, studying air pollution. the system requires a rather large investment, but the daily cost and quantities of material used are small. The underlying study of the literature and the discussion of statistical methods used are available to the interested reader.
Gu, Jianghong; Tifft, Cynthia J; Soldin, Steven J
2008-04-01
Gangliosides (GGs) are considered as diagnostic biomarkers and therapeutic targets and agents. The goal of this study was to develop a tandem mass spectrometry (MS/MS) method for the simultaneous measurement of both GM1 and GM2 gangliosides in human cerebrospinal fluid (CSF) samples in order to be able to determine their concentrations in patients with Tay-Sachs and Sandhoff disease and assess whether drugs or transplantation affect their concentrations. An API-4000 tandem mass spectrometer equipped with TurboIonSpray source and Shimadzu HPLC system was employed to perform the analysis using isotope dilution with deuterium labeled internal standards. To a 1.5 mL conical plastic Eppendorf centrifuge tube, 40 microL of human CSF sample was added and mixed with 400 microL of internal standard solution for deproteinization. After centrifugation, 100 microL of supernatant was injected onto a C-18 column. After a 2.5 min wash, the switching valve was activated and the analytes were eluted from the column with a water/methanol gradient into the MS/MS system. Quantification by multiple reaction-monitoring (MRM) analysis was performed in the negative mode. The within-day coefficients of variation were <3% for GM1 and <2% for GM2 and the between-day coefficients of variation were <5% for both GM1 and GM2 at all concentrations tested. Accuracy ranged between 98% and 102% for both analytes. Good linearity was also obtained within the concentration range of 10-200 ng/mL (6.5-129.3 nmol/L) for GM1 and 5-100 ng/mL (3.6-72.3 nmol/L) for GM2 (r> or =0.995). A new simple, accurate, and fast isotope dilution tandem mass spectrometry method was developed for the simultaneous quantification of GM1 and GM2 gangliosides in a small amount of human CSF. Concentrations were measured in "normal" CSF and in CSF from patients with Tay-Sachs disease.
Differential auger spectrometry
Strongin, Myron; Varma, Matesh Narayan; Anne, Joshi
1976-06-22
Differential Auger spectroscopy method for increasing the sensitivity of micro-Auger spectroanalysis of the surfaces of dilute alloys, by alternately periodically switching an electron beam back and forth between an impurity free reference sample and a test sample containing a trace impurity. The Auger electrons from the samples produce representative Auger spectrum signals which cancel to produce an Auger test sample signal corresponding to the amount of the impurity in the test samples.
Oxotremorine does not enhance acetylcholine release from rat diaphragm preparations.
Gundersen, C. B.; Jenden, D. J.
1980-01-01
We have reinvestigated the dramatic effect of oxotremorine on acetylcholine release from the rat diaphragm reported by Das, Ganguly & Vedasiromoni (1978), using a rigorous gas chromatographic mass spectrometric/isotope dilution method for identification and measurement of acetylcholine and choline. Oxotremorine (10 microM) causes no significant change in the spontaneous or evoked (1 or 10 Hz) release or in the tissue levels of acetylcholine or choline. PMID:7426831
Effect of micro-aeration on anaerobic digestion of primary sludge under septic tank conditions.
Diak, James; Örmeci, Banu; Kennedy, Kevin J
2013-04-01
Micro-aeration, which refers to the addition of very small amounts of air, is a simple technology that can potentially be incorporated in septic tanks to improve the digestion performance. The purpose of this study was to investigate and compare the effects of micro-aeration on anaerobic digestion of primary sludge under septic tank conditions. 1.6 L batch reactor experiments were carried out in duplicate using raw primary sludge, with 4.1 % total solids, and diluted primary sludge, with 2.1 % total solids. Reactors were operated for 5 weeks at room temperature to simulate septic tank conditions. Micro-aeration rate of 0.00156 vvm effectively solubilised chemical oxygen demand (COD) and improved the subsequent degradation of COD. Micro-aeration also increased the generation of ammonia and soluble proteins, but did not improve the reduction in total and volatile solids, or the reduction in carbohydrates. Experiments using diluted sludge samples showed similar trends as the experiments with raw sludge, which suggest that initial solids concentration did not have a significant effect on the degradation of primary sludge under septic tank conditions.
Moyle, Richard L.; Carvalhais, Lilia C.; Pretorius, Lara-Simone; Nowak, Ekaterina; Subramaniam, Gayathery; Dalton-Morgan, Jessica; Schenk, Peer M.
2017-01-01
Studies investigating the action of small RNAs on computationally predicted target genes require some form of experimental validation. Classical molecular methods of validating microRNA action on target genes are laborious, while approaches that tag predicted target sequences to qualitative reporter genes encounter technical limitations. The aim of this study was to address the challenge of experimentally validating large numbers of computationally predicted microRNA-target transcript interactions using an optimized, quantitative, cost-effective, and scalable approach. The presented method combines transient expression via agroinfiltration of Nicotiana benthamiana leaves with a quantitative dual luciferase reporter system, where firefly luciferase is used to report the microRNA-target sequence interaction and Renilla luciferase is used as an internal standard to normalize expression between replicates. We report the appropriate concentration of N. benthamiana leaf extracts and dilution factor to apply in order to avoid inhibition of firefly LUC activity. Furthermore, the optimal ratio of microRNA precursor expression construct to reporter construct and duration of the incubation period post-agroinfiltration were determined. The optimized dual luciferase assay provides an efficient, repeatable and scalable method to validate and quantify microRNA action on predicted target sequences. The optimized assay was used to validate five predicted targets of rice microRNA miR529b, with as few as six technical replicates. The assay can be extended to assess other small RNA-target sequence interactions, including assessing the functionality of an artificial miRNA or an RNAi construct on a targeted sequence. PMID:28979287
NASA Astrophysics Data System (ADS)
Li, Kai; Liu, Jun-kao; Chen, Wei-shan; Ye, Le; Zhang, Lu
2016-08-01
In order to solve the problem of lubrication failure in bearing systems, a novel lubricating device which can achieve drop-on-demand lubrication is proposed based on piezoelectric micro-jet technology. The injection performance of the novel piezoelectric micro-jet lubricating device are analyzed in this paper. The influences of the fluid-structure interaction to the working frequency are studied by comparing the results of tests with simulations. A method used to forecast the working frequency of the micro-jet is proved to be available. A velocity inlet boundary model at the nozzle is derived under the assumption that the lubricating oil cannot be pressed. Combined with this model, the influences of density, dynamic viscosity and surface tension of the lubricating oil on the injection performance are discussed according to the simulation results. An experiment on the injection performance of the micro-jet for ejecting lubricating oil with different dilution ratios is performed. The recommended excitations are given for ejecting lubricating oil with different properties by analyzing the results.
A MODIFIED PROTEIN ASSAY FROM MICROGRAM TO LOW NANOGRAM LEVELS IN DILUTE SAMPLES
Heda, Ghanshyam D.; Kunwar, Upasana; Heda, Rajiv P.
2013-01-01
In this paper we present a modified and improved protein assay that was previously described as ‘amidoschwarz assay’ by Schaffner and Weissmann (Anal. Biochem. 56, 1973, 502–514). Our improved protein assay is user-friendly and 30 to 40 times more sensitive than the earlier method. The assay was developed into 3 formats (maco, micro, and nanoassay) with TCA as protein precipitating agent; measuring up to 96 samples. The macro and micro formats of this assay require a single reagent staining with amido black of protein dots, bound to nitrocellulose membrane with lowest protein measurements to 1 μg and 0.1 μg respectively. The nanoassay on the other hand with combination staining of amido black followed by colloidal gold can extend the detection limit to 2.5 ng of protein. Protein concentrations were determined by densitometry and/or spectrophotometry. This assay is compatible with many ionic and non-ionic detergents. This improved protein assay provides an additional choice to researchers in measuring total protein concentration accurately in dilute biological samples as low as 0.125 μg/ml, prior to their biochemical analysis such as in comparative proteomics. PMID:24135655
Márta, Zoltán; Bobály, Balázs; Fekete, Jenő; Magda, Balázs; Imre, Tímea; Mészáros, Katalin Viola; Bálint, Mária; Szabó, Pál Tamás
2018-02-20
Ultratrace analysis of sample components requires excellent analytical performance in terms of limits of quantitation (LOQ). Micro UHPLC coupled to sensitive tandem mass spectrometry provides state of the art solution for such analytical problems. Using on-line SPE with column switching on a micro UHPLC-MS/MS system allowed to decrease LOQ without any complex sample preparation protocol. The presented method is capable of reaching satisfactory low LOQ values for analysis of thirteen different steroid molecules from human plasma without the most commonly used off-line SPE or compound derivatization. Steroids were determined by using two simple sample preparation methods, based on lower and higher plasma steroid concentrations. In the first method, higher analyte concentrations were directly determined after protein precipitation with methanol. The organic phase obtained from the precipitation was diluted with water and directly injected into the LC-MS system. In the second method, low steroid levels were determined by concentrating the organic phase after steroid extraction. In this case, analytes were extracted with ethyl acetate and reconstituted in 90/10 water/acetonitrile following evaporation to dryness. This step provided much lower LOQs, outperforming previously published values. The method has been validated and subsequently applied to clinical laboratory measurement. Copyright © 2017 Elsevier B.V. All rights reserved.
A miniaturized fibrinolytic assay for plasminogen activators
NASA Technical Reports Server (NTRS)
Lewis, M. L.; Nachtwey, D. S.; Damron, K. L.
1991-01-01
This report describes a micro-clot lysis assay (MCLA) for evaluating fibrinolytic activity of plasminogen activators (PA). Fibrin clots were formed in wells of microtiter plates. Lysis of the clots by PA, indicated by change in turbidity (optical density, OD), was monitored with a microplate reader at five minutes intervals. Log-log plots of PA dilution versus endpoint, the time at which the OD value was halfway between the maximum and minimum value for each well, were linear over a broad range of PA concentrations (2-200 International units/ml). The MCLA is a modification and miniaturization of well established fibrinolytic methods. The significant practical advantages of the MCLA are that it is a simple, relatively sensitive, non-radioactive, quantitative, kinetic, fibrinolytic micro-technique which can be automated.
Microbial biodegradation of organic wastes containing surfactants in a continuous-flow reactor.
Konopka, A; Zakharova, T; Oliver, L; Turco, R F
1997-04-01
In a continuous flow bioreactor seeded with microbes from municipal activated sludge, complete organic carbon oxidation of simulated graywater (wastewater produced in human residences, excluding toilet wastes) was achieved at dilution rates up to 0.36 h-1 in the presence of 64.1 microM linear alkylbenzenesulfonate (LAS) L-1. At LAS concentrations of 187 microM, the system functioned only at dilution rates up to 0.23 h-1, and the biomass yield was two-fold lower. There were physiological changes in the microbial communities under different operating conditions, as measured by specific contents of ATP and extracellular hydrolases as well as the respiratory potential of the biomass. LAS inhibited the activity of LAS-degrading microbes at >150 microM LAS, and the activity of other microbes at >75 microM LAS. Chemical analysis of graywater indicated that samples consisted primarily of biological polymers (proteins and polysaccharides) and lower concentrations of surfactants. Biological remediation of graywater is possible, although treatment efficiency is influenced by the operating conditions and wastestream composition.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Singer, Brett C.; Destaillat, Hugo; Hodgson, Alfred T.
2005-08-01
Experiments were conducted to quantify emissions and concentrations of glycol ethers and terpenoids from cleaning product and air freshener use in a 50-m{sup 3} room ventilated at {approx}0.5 h{sup -1}. Five cleaning products were applied full-strength (FS); three were additionally used in dilute solution. FS application of pine-oil cleaner (POC) yielded 1-h concentrations of 10-1300 {micro}g m{sup -3} for individual terpenoids, including {alpha}-terpinene (90-120), d-limonene (1000-1100), terpinolene (900-1300), and {alpha}-terpineol (260-700). One-hour concentrations of 2-butoxyethanol and/or dlimonene were 300-6000 {micro}g m{sup -3} after FS use of other products. During FS application including rinsing with sponge and wiping with towels, fractionalmore » emissions (mass volatilized/dispensed) of 2-butoxyethanol and d-limonene were 50-100% with towels retained, {approx}25-50% when towels were removed after cleaning. Lower fractions (2-11%) resulted from dilute use. Fractional emissions of terpenes from FS use of POC were {approx}35-70% with towels retained, 20-50% with towels removed. During floor cleaning with dilute solution of POC, 7-12% of dispensed terpenes were emitted. Terpene alcohols were emitted at lower fractions: 7-30% (FS, towels retained), 2-9% (FS, towels removed), and 2-5% (dilute). During air-freshener use, d-limonene, dihydromyrcenol, linalool, linalyl acetate, and {beta}-citronellol were emitted at 35-180 mg d{sup -1} over three days while air concentrations averaged 30-160 {micro}g m{sup -3}.« less
Fernandez-Alvarez, Maria; Llompart, Maria; Lamas, J Pablo; Lores, Marta; Garcia-Jares, Carmen; Cela, Rafael; Dagnac, Thierry
2008-06-09
A simple and rapid method based on solid-phase microextraction (SPME) technique followed by gas chromatography with microelectron-capture detection (GC-microECD) was developed for the simultaneous determination of more than 30 pesticides (pyrethroids and organochlorinated among others) in milk. To our knowledge, this is the first application of SPME for the determination of pyrethroid pesticides in milk. Negative matrix effects due to the complexity and lipophility of the studied matrix were reduced by diluting the sample with distilled water. A 2(5-1) fractional factorial design was performed to assess the influence of several factors (type of fiber coating, sampling mode, stirring, extraction temperature, and addition of sodium chloride) on the SPME procedure and to determine the optimal extraction conditions. After optimization of all the significant variables and interactions, the recommended procedure was established as follows: DSPME (using a polydimethylsiloxane (PDMS)/divinylbenzene (DVB) coating) of 1 mL of milk sample diluted with Milli-Q water (1:10 dilution ratio), at 100 degrees C, under stirring for 30 min. The proposed method showed good linearity and high sensitivity, with limits of detection (LOD) at the sub-ng mL(-1) level. Within a day and among days precisions were also evaluated (R.S.D.<15%). One of the most important attainments of this work was the use of external calibration with milk-matched standards to quantify the levels of the target analytes. The method was tested with liquid and powdered milk samples with different fat contents covering the whole commercial range. The efficiency of the extraction process was studied at several analyte concentration levels obtaining high recoveries (>80% in most cases) for different types of full-fat milks. The optimized procedure was validated with powdered milk certified reference material, which was quantified using external calibration and standard addition protocols. Finally, the DSPME-GC-microECD methodology was applied to the analysis of milk samples collected in farms of dairy cattle from NW Spain.
Rapid micro-scale proteolysis of proteins for MALDI-MS peptide mapping using immobilized trypsin
NASA Astrophysics Data System (ADS)
Gobom, Johan; Nordhoff, Eckhard; Ekman, Rolf; Roepstorff, Peter
1997-12-01
In this study we present a rapid method for tryptic digestion of proteins using micro-columns with enzyme immobilized on perfusion chromatography media. The performance of the method is exemplified with acyl-CoA-binding protein and reduced carbamidomethylated bovine serum albumin. The method proved to be significantly faster and yielded a better sequence coverage and an improved signal-to-noise ratio for the MALDI-MS peptide maps, compared to in-solution- and on-target digestion. Only a single sample transfer step is required, and therefore sample loss due to adsorption to surfaces is reduced, which is a critical issue when handling low picomole to femtomole amounts of proteins. An example is shown with on-column proteolytic digestion and subsequent elution of the digest into a reversed-phase micro-column. This is useful if the sample contains large amounts of salt or is too diluted for MALDI-MS analysis. Furthermore, by step-wise elution from the reversedphase column, a complex digest can be fractionated, which reduces signal suppression and facilitates data interpretation in the subsequent MS-analysis. The method also proved useful for consecutive digestions with enzymes of different cleavage specificity. This is exemplified with on-column tryptic digestion, followed by reversed-phase step-wise elution, and subsequent on-target V8 protease digestion.
Van, Linh M; Heydari, Amir; Yang, Jiansong; Hargreaves, Judith; Rowland-Yeo, Karen; Lennard, Martin S; Tucker, Geoffrey T; Rostami-Hodjegan, Amin
2006-11-01
MDMA (3-4-methylenedioxymethamphetamine, commonly known as Ecstasy) is a potent mechanism-based inhibitor (MBI) of cytochrome P450 2D6 (CYP2D6), causing quasi-irreversible inhibition of the enzyme in vitro. An evaluation of the in vivo implications of this phenomenon depends on the accuracy of the estimates of the parameters that define the inhibition in vitro, namely k(inact) (the maximal inhibition rate) and KI (the inactivation constant). These values are determined in two steps, pre-incubation of the enzyme with the inhibitor (enzyme inactivation), followed by dilution and further incubation to measure residual enzyme activity with a probe substrate. The aim of this study was to assess the impact of different dilutions and probe substrate concentrations on the estimates of k(inact) and KI using recombinantly expressed CYP2D6. Enzyme activity was measured by the conversion of dextromethorphan (DEX) to dextrorphan (DOR). Dilution factors of 1.25, 2, 5, 10, 25 and 50 (DEX at 30 microM) gave mean (+/-SE) values of k(inact) (min-1) of 0.20+/-0.06, 0.21+/-0.05, 0.31+/-0.06, 0.37+/-0.11, 0.51+/-0.10 and 0.58+/-0.08, respectively, and KI (microM) values (after correction for non-specific microsomal binding) of 2.22+/-1.90, 2.80+/-1.34, 5.78+/-2.07, 6.36+/-2.93, 3.99+/-1.57 and 4.86+/-1.37, respectively. Accordingly, high (e.g. 50 fold) and low (e.g. 1.25 fold) dilutions were associated with statistically significant differences in kinetic values (p <0.05). Varying DEX concentration (10-100 microM) was not associated with significant changes in k(inact) and KI values when a five-fold dilution was used (with the exception of a lower KI at 10 microM DEX). High dilution was also shown to reduce non-specific microsomal binding of MDMA. The changes in the two kinetic parameters were dependent on the experimental procedure and shown to be unlikely to have a material influence on the maximum inhibition of CYP2D6 expected in vivo after typical recreational doses of MDMA (50-100 mg), since the potency of inhibition was high. The different values of the kinetic parameters were predicted to have a marginal influence on the time for recovery of enzyme activity following re-synthesis of CYP2D6.
Zhang, Meng-Qi; Jia, Jing-Ying; Lu, Chuan; Liu, Gang-Yi; Yu, Cheng-Yin; Gui, Yu-Zhou; Liu, Yun; Liu, Yan-Mei; Wang, Wei; Li, Shui-Jun; Yu, Chen
2010-06-01
A simple, reliable and sensitive liquid chromatography-isotope dilution mass spectrometry (LC-ID/MS) was developed and validated for quantification of olanzapine in human plasma. Plasma samples (50 microL) were extracted with tert-butyl methyl ether and isotope-labeled internal standard (olanzapine-D3) was used. The chromatographic separation was performed on XBridge Shield RP 18 (100 mm x 2.1 mm, 3.5 microm, Waters). An isocratic program was used at a flow rate of 0.4 m x min(-1) with mobile phase consisting of acetonitrile and ammonium buffer (pH 8). The protonated ions of analytes were detected in positive ionization by multiple reactions monitoring (MRM) mode. The plasma method, with a lower limit of quantification (LLOQ) of 0.1 ng x mL(-1), demonstrated good linearity over a range of 0.1 - 30 ng x mL(-1) of olanzapine. Specificity, linearity, accuracy, precision, recovery, matrix effect and stability were evaluated during method validation. The validated method was successfully applied to analyzing human plasma samples in bioavailability study.
Generation of micro- and nano-droplets containing immiscible solutions in view of optical studies
NASA Astrophysics Data System (ADS)
Nastasa, V.; Karapantsios, T.; Samaras, K.; Dafnopatidou, E.; Pradines, V.; Miller, R.; Pascu, M. L.
2010-08-01
The multiple resistances to treatment, developed by bacteria and malignant tumors require finding alternatives to the existing medicines and treatment procedures. One of them is strengthening the effects of cytostatics by improving the delivery method. Such a method is represented by the use of medicines as micro/nano-droplets. This method can reduce the substance consumption by generating drug micro-droplets incorporated in substances that can favour a faster localization, than the classical mode of medicine administration, to the tumor tissues. This paper contains the results concerning the generation and study of micro/nano-droplets and the generation of micro-droplets with an inner core (medicine) and a thin layer covering it. We have measured the surface tension at water/air interface and water/oil interface for a medicine (Vancomycin) and we have generated and measured droplets of medicine containing a layer of Vitamin A by using a double capillary system. The micro/nano-droplets may be produced by mixing of two immiscible solutions in particular conditions (high rotating speed and/or high pressure difference). For this we have studied the generation of emulsions of vitamin A diluted in sunflower oil and a solution of a surfactant Tween 80 in distilled water. The concentration of surfactant in water was typically 4*10-5M. We have studied in a batch stirred tank system the dependence of the droplet dimensions in emulsion, function of the mixing rotation speed, agitation time and components ratio. The droplet diameters were measured using a Malvern light scattering instrument type Mastersizer Hydro 2000M. We have obtained droplets with diameters smaller than 100 nm; the diameters distribution exhibited a peak at 65 nm.
Ghotaslou, Reza; Bahrami, Nashmil
2012-01-01
Purpose: The aim of present study was to investigate the effect of chemical agents on the clinical isolates in Madani Heart Hospital, Tabriz, Iran. Methods: The minimum bactericide concentration (MBC) of disinfectants including chlorhexidine (Fort), peracetic acid (Micro) and an alcohol based compound (Deconex) on selected bacteria at various dilutions were determined by the standard suspension technique. Results: MBC of Micro, Fort and Deconex were 2-128 mg/L, 2-64 mg/L and 4 - 32 mg/L, respectively. The Gram negative bacteria were more resistance to disinfectant relation to Gram positive bacteria. Conclusion: The results showed that these agents are able to eradicate the bacteria and they can be used lonely. PMID:24312771
Murase, Tetsuma; Imaeda, Noriaki; Yamada, Hiroto; Takasu, Masaki; Taguchi, Kazuo; Katoh, Tsutomu
2010-06-01
The present study investigated whether substitution of HEPES for bicarbonate in BTS (BTS-H) used to dilute boar ejaculates immediately after ejaculation could reduce the increased inducibility of the acrosome reaction by calcium and calcium ionophore A23187. When an ejaculate was split, diluted 5-fold with regular BTS (BTS-B) and BTS-H and stored at 17 C for 12 h or 60 h, the extender or storage time had no significant influence on sperm motility or viability measured by the eosin-nigrosin method. When spermatozoa diluted serially with BTS-B and stored (36 h) were stimulated with Ca2+ (3 mM) and A23187 (0.3 microM), the proportion of spermatozoa that underwent the acrosome reaction (% acrosome reactions) significantly increased as the magnifications of dilution increased (bicarbonate content almost unchanged by dilution). By contrast, the % acrosome reactions in spermatozoa similarly diluted and stored with BTS-H decreased with the increasing magnifications of dilution (bicarbonate decreased). Sperm motility immediately after the end of incubation without A23178 tended to be lower for BTS-H than BTS-B, and the ejaculates for BTS-H had a tendency to have a lower total protein in seminal plasma than those for BTS-B. These results implied that the samples for BTS-H could be used as a model for ejaculates possibly collected during summer and showing subfertility. When an ejaculate was split, diluted serially with BTS-B and BTS-H and stored, viability measured by staining with propidium iodide was extremely similar between the 2 extenders and among the different dilution magnifications, regardless of whether spermatozoa were washed (stored for 36-66 h) or not (stored for 66-72 h). These results suggest that boar ejaculate can be stored with BTS-H at least according to the results for sperm motility and viability and that hypersensitivity of spermatozoa to Ca2+ and A23187 potentially associated with boar subfertility could be lessened by diluting ejaculates with BTS-H.
Gangidi, R R; Metzger, L E
2006-11-01
The purpose of this study was to determine if the ionic calcium content of skim milk could be determined using molecular probes and front-face fluorescence spectroscopy. Current methods for determining ionic calcium are not sensitive, overestimate ionic calcium, or require complex procedures. Molecular probes designed specifically for measuring ionic calcium could potentially be used to determine the ionic calcium content of skim milk. The goal of the current study was to develop foundation methods for future studies to determine ionic calcium directly in skim milk and other dairy products with molecular probes and fluorescence spectroscopy. In this study, the effect of pH on calcium-sensitive fluorescent probe (Rhod-5N and Fluo-5N) performance using various concentrations of skim milk was determined. The pH of diluted skim milk (1.9 to 8.9% skim milk), was adjusted to either 6.2 or 7.0, after which the samples were analyzed with fluorescent probes (1 microM) and front-face fluorescence spectroscopy. The ionic calcium content of each sample was also determined using a calcium ion-selective electrode. The results demonstrated that the ionic calcium content of each sample was highly correlated (R2 > 0.989) with the fluorescence intensities of the probe-calcium adduct using simple linear regression. Higher than suggested ionic calcium contents of 1,207 and 1,973 microM were determined with the probes (Fluo-5N and Rhod-5N) in diluted skim milk with pH 7.0 and 6.2, respectively. The fluorescence intensity of the probe-calcium adduct decreased with a decrease in pH for the same ionic calcium concentration. This study demonstrates that Fluo-5N and Rhod-5N can be used to determine the ionic-calcium content of diluted milk with front-face fluorescence spectroscopy. Furthermore, these probes may also have the potential to determine the ionic calcium content of undiluted skim milk.
He, Qingwen; Chen, Weiyuan; Huang, Liya; Lin, Qili; Zhang, Jingling; Liu, Rui; Li, Bin
2016-06-21
Carbapenem-resistant Enterobacteriaceae (CRE) is prevalent around the world. Rapid and accurate detection of CRE is urgently needed to provide effective treatment. Automated identification systems have been widely used in clinical microbiology laboratories for rapid and high-efficient identification of pathogenic bacteria. However, critical evaluation and comparison are needed to determine the specificity and accuracy of different systems. The aim of this study was to evaluate the performance of three commonly used automated identification systems on the detection of CRE. A total of 81 non-repetitive clinical CRE isolates were collected from August 2011 to August 2012 in a Chinese university hospital, and all the isolates were confirmed to be resistant to carbapenems by the agar dilution method. The potential presence of carbapenemase genotypes of the 81 isolates was detected by PCR and sequencing. Using 81 clinical CRE isolates, we evaluated and compared the performance of three automated identification systems, MicroScan WalkAway 96 Plus, Phoenix 100, and Vitek 2 Compact, which are commonly used in China. To identify CRE, the comparator methodology was agar dilution method, while the PCR and sequencing was the comparator one to identify CPE. PCR and sequencing analysis showed that 48 of the 81 CRE isolates carried carbapenemase genes, including 23 (28.4 %) IMP-4, 14 (17.3 %) IMP-8, 5 (6.2 %) NDM-1, and 8 (9.9 %) KPC-2. Notably, one Klebsiella pneumoniae isolate produced both IMP-4 and NDM-1. One Klebsiella oxytoca isolate produced both KPC-2 and IMP-8. Of the 81 clinical CRE isolates, 56 (69.1 %), 33 (40.7 %) and 77 (95.1 %) were identified as CRE by MicroScan WalkAway 96 Plus, Phoenix 100, and Vitek 2 Compact, respectively. The sensitivities/specificities of MicroScan WalkAway, Phoenix 100 and Vitek 2 were 93.8/42.4 %, 54.2/66.7 %, and 75.0/36.4 %, respectively. The MicroScan WalkAway and Viteck2 systems are more reliable in clinical identification of CRE, whereas additional tests are required for the Pheonix 100 system. Our study provides a useful guideline for using automated identification systems for CRE identification.
Mechanistic investigations in sono-hybrid techniques for rice straw pretreatment.
Suresh, Kelothu; Ranjan, Amrita; Singh, Shuchi; Moholkar, Vijayanand S
2014-01-01
This paper reports comparative study of two chemical techniques (viz. dilute acid/alkali treatment) and two physical techniques (viz. hot water bath and autoclaving) coupled with sonication, termed as sono-hybrid techniques, for hydrolysis of rice straw. The efficacy of each sono-hybrid technique was assessed on the basis of total sugar and reducing sugar release. The system of biomass pretreatment is revealed to be mass transfer controlled. Higher sugar release is obtained during dilute acid treatment than dilute alkali treatment. Autoclaving alone was found to increase sugar release marginally as compared to hot water bath. Sonication of the biomass solution after autoclaving and stirring resulted in significant rise of sugar release, which is attributed to strong convection generated during sonication that assists effective transport of sugar molecules. Discrimination between individual contributions of ultrasound and cavitation to mass transfer enhancement reveals that contribution of ultrasound (through micro-streaming) is higher. Micro-turbulence as well as acoustic waves generated by cavitation did not contribute much to enhancing of mass transfer in the system. Copyright © 2013 Elsevier B.V. All rights reserved.
Robinson, S; Follo, M; Haenel, D; Mauler, M; Stallmann, D; Tewari, M; Duerschmied, D; Peter, K; Bode, C; Ahrens, I; Hortmann, M
2018-04-15
micro-RNAs have shown promise as potential biomarkers for acute myocardial infarction and ischemia-reperfusion injury (I/R). Most recently droplet digital polymerase chain reaction (ddPCR) has been introduced as a more reliable and reproducible method for detecting micro-RNAs. We aimed to demonstrate the improved technical performance and diagnostic potential of ddPCR by measuring micro-RNAs in ST-elevation myocardial infarction (STEMI). A dilution series was performed in duplicate on synthetic Caenorrhabditis elegans-miR-39, comparing quantitative real-time PCR (qRT-PCR) and ddPCR. We used ddPCR and qRT-PCR to quantify the serum levels of miR-21, miR-208a and miR-499 between STEMI patients (n=24) and stable coronary artery disease (CAD) patients (n=20). In STEMI, I/R injury was assessed via measurement of ST-segment resolution. In the dilution series, ddPCR demonstrated superior coefficient of variation (12.1%vs.32.9%) and limit of detection (0.9325 vs.2.425copies/μl). In the patient cohort, ddPCR demonstrated greater differences in miR-21 levels (2190.5 vs. 484.7copies/μl; p=0.0004 for ddPCR and 136.4 vs. 122.8copies/μl; p=0.2273 for qRT-PCR) and in miR-208a (0 vs. 24.1copies/μl, p=0.0013 for ddPCR and 0 vs. 0copies/μl, p=0.0032 for qRT-PCR), with similar differences observed in miR-499 levels (9.4 vs. 81.5copies/μl, p<0.0001 for ddPCR and 0 vs. 19.41copies/μl, p<0.0001 for qRT-PCR). ddPCR also more accurately defined STEMI for all miRNAs (area under the curve (AUC) of 0.8021/0.7740/0.9063 for miR-21/208a/499 with ddPCR vs. AUC of 0.6083/0.6917/0.8417 with qRT-PCR). However, there was no association between miR-21/208a/499 levels and ischemia-reperfusion injury. ddPCR demonstrates superiority in both technical performance and diagnostic potential compared to qRT-PCR. Ultimately, this supports its use as a diagnostic method for quantifying micro-RNAs, particularly in large multi-center trials. Copyright © 2017 Elsevier B.V. All rights reserved.
Micro-organization of humic acids in aqueous solutions
NASA Astrophysics Data System (ADS)
Klučáková, Martina; Věžníková, Kateřina
2017-09-01
The methods of dynamic light scattering and micro-rheology were used to investigate the molecular organization of humic acids in solutions. The obtained results were supplemented by ultraviolet/visible spectrometry and measurement of the zeta potential. Particle tracking micro-rheology was used for the first time as a novel method in humic research. Solutions of humic acids were prepared in three different mediums: NaOH, NaCl, and NaOH neutralized by HCl after dissolution of the humic sample. The molecular organization of humic acids was studied over a wide concentration range (0.01-10 g dm-3). Two breaks were detected in the obtained concentration dependencies. The rearrangements were observed at concentrations around 0.02 g dm-3 and 1 g dm-3. Changes in the measured values observed at around 0.02 g dm-3 were less noticeable and were related to the formation of particles between 100 and 1000 nm in size and the strong bimodal character of humic systems diluted by NaCl. The ;switch-over point; at around 1 g dm-3 indicated changes in the secondary structure of humic acids connected with the increase in colloidal stability (decrease of zeta potential), the decrease in polydispersity, and minimal values of viscosity.
Low, N H; McLaughlin, M A; Page, S W; Canas, B J; Brause, A R; Low, N H
2001-01-01
A peer-verified, gas chromatographic (GC) method is presented for the identification of hydrolyzed inulin syrup (HIS) and high-fructose corn syrup (HFCS) in apple juice. The procedure involves determining the Brix value of the apple juice or apple juice concentrate and preparing a dilution of the test sample to 5.5 degrees Brix. A 100 microL aliquot of the 5.5 degrees Brix test solution is then freeze-dried in a GC autosampler vial. The sugars in the freeze-dried residue are converted to trimethylsilyl derivatives, by the addition of an appropriate silylation reagent, and the vial is heated at 75 degrees C for 30 min. After derivatization, the solution is introduced into a gas chromatograph where the analytes are separated on a 30 m, 0.25 mm id DB-5 column. The method can use hydrogen, helium, or nitrogen as the carrier gas. The analytes and marker compounds are measured by use of a flame ionization detecone of the 2 syrups at 2 levels. Dilution was ascertained by the presence of retrograde sugar markers found in the 2 sugar syrups. All 3 laboratories involved in the study were able to identify the correct diluent in the blind, randomly coded, apple juice test portions. The levels of dilution in the test portions were 0, 6.9% (HIS), 16.0% (HIS), 8.1% (HFCS), and 17.0% (HFCS). No false positive results were reported. Quantitative conclusions can be drawn when the same syrup is used for dilution and as a reference standard.
Pankuch, Glenn A; Kelly, Linda M; Lin, Gengrong; Bryskier, Andre; Couturier, Catherine; Jacobs, Michael R; Appelbaum, Peter C
2003-10-01
MIC methodology was used to test the antibacterial activity of XRP 2868, a new oral combination of two semisynthetic streptogramins, RPR 132552A and RPR 202868, compared to activities of other antibacterial agents against pneumococci, Haemophilus influenzae, and Haemophilus parainfluenzae. For 261 pneumococci, XRP 2868 and pristinamycin MICs were similar, irrespective of penicillin G and erythromycin A susceptibilities (MIC at which 50% of isolates were inhibited [MIC(50)], 0.25 micro g/ml; MIC(90), 0.5 micro g/ml), while quinupristin/dalfopristin had MICs which were 1 to 2 dilutions higher. Single components of both XRP 2868 and quinupristin/dalfopristin had higher MICs. Erythromycin A, azithromycin, clarithromycin, and clindamycin MICs were higher for penicillin G-intermediate and -resistant than -susceptible pneumococci. Against 150 H. influenzae strains, all compounds tested had unimodal MIC distributions. XRP 2868 had an overall MIC(50) of 0.25 micro g/ml and an MIC(90) of 1.0 micro g/ml, with no differences between beta-lactamase-positive, beta-lactamase-negative, and beta-lactamase-negative ampicillin-resistant strains. Of note was the similarly low activity of one of its components, RPR 132552A. Pristinamycin and quinupristin/dalfopristin had MICs of 0.125 to 8.0 micro g/ml; quinupristin alone had MICs of 8.0 to >64.0 micro g/ml, and dalfopristin had MICs of 1.0 to >64.0 micro g/ml. Erythromycin A, azithromycin, and clarithromycin had modal MICs of 4.0, 1.0, and 8.0 micro g/ml, respectively. MICs of all compounds against H. parainfluenzae were 1 to 2 dilutions higher than against H. influenzae. XRP 2868 showed potent activity against pneumococci and Haemophilus strains irrespective of their susceptibility to other agents.
Ramos, Inês I; Magalhães, Luís M; Barreiros, Luisa; Reis, Salette; Lima, José L F C; Segundo, Marcela A
2018-01-01
Immunoglobulin G (IgG) represents the major fraction of antibodies in healthy adult human serum, and deviations from physiological levels are a generic marker of disease corresponding to different pathologies. Therefore, screening methods for IgG evaluation are a valuable aid to diagnostics. The present work proposes a rapid, automatic, and miniaturized method based on UV-vis micro-bead injection spectroscopy (μ-BIS) for the real-time determination of human serum IgG with label-free detection. Relying on attachment of IgG in rec-protein G immobilized in Sepharose 4B, a bioaffinity column is automatically assembled, where IgG is selectively retained and determined by on-column optical density measurement. A "dilution-and-shoot" approach (50 to 200 times) was implemented without further sample treatment because interferences were flushed out of the column upon sample loading, with minimization of carryover and cross-contamination by automatically discarding the sorbent (0.2 mg) after each determination. No interference from human serum albumin at 60 mg mL -1 in undiluted sample was found. The method allowed IgG determination in the range 100-300 μg mL -1 (corresponding to 5.0-60 mg mL -1 in undiluted samples), with a detection limit of 33 μg mL -1 (1.7 mg mL -1 for samples, dilution factor of 50). RSD values were < 9.4 and < 11.7%, for intra and inter-assay precision, respectively, while recovery values for human serum spiked with IgG at high pathological levels were 97.8-101.4%. Comparison to commercial ELISA kit showed no significant difference for tested samples (n = 8). Moreover, time-to-result decreased from several hours to < 5 min and analysis cost decreased 10 times, showing the potential of the proposed approach as a point-of-care method. Graphical abstract Micro-Bead Injection Spectroscopy method for real time, automated and label-free determination of total serum human Immunoglobulin G (IgG). The method was designed for Lab-on-Valve (LOV) platforms using a miniaturised protein G bioaffinity separative approach. IgG are separated from serum matrix components upon quantification with low non-specific binding in less than 5 min.
Giri, Anupam; Zelinkova, Zuzana; Wenzl, Thomas
2017-12-01
For the implementation of Regulation (EC) No 2065/2003 related to smoke flavourings used or intended for use in or on foods a method based on solid-phase micro extraction (SPME) GC/MS was developed for the characterisation of liquid smoke products. A statistically based experimental design (DoE) was used for method optimisation. The best general conditions to quantitatively analyse the liquid smoke compounds were obtained with a polydimethylsiloxane/divinylbenzene (PDMS/DVB) fibre, 60°C extraction temperature, 30 min extraction time, 250°C desorption temperature, 180 s desorption time, 15 s agitation time, and 250 rpm agitation speed. Under the optimised conditions, 119 wood pyrolysis products including furan/pyran derivatives, phenols, guaiacol, syringol, benzenediol, and their derivatives, cyclic ketones, and several other heterocyclic compounds were identified. The proposed method was repeatable (RSD% <5) and the calibration functions were linear for all compounds under study. Nine isotopically labelled internal standards were used for improving quantification of analytes by compensating matrix effects that might affect headspace equilibrium and extractability of compounds. The optimised isotope dilution SPME-GC/MS based analytical method proved to be fit for purpose, allowing the rapid identification and quantification of volatile compounds in liquid smoke flavourings.
Ohta, Merime; Toba, Shinsuke; Ito, Akinobu; Nakamura, Rio; Tsuji, Masakatsu
2012-12-01
This study evaluated the in vitro activity of doripenem (DRPM) against 200 Streptococcus pneumoniae and 197 Haemophilus influenzae from children and adults in 2007, 50 H. influenzae type b in 2006, 20 Listeria monocytogenes in 1990-2005, 23 Neisseria meningitidis in 2007-2009 and 83 Bordetella pertussis in 1989-2003. All strains were isolated from Japanese clinical facilities. We also investigated in vitro activity of other carbapenems (meropenem, imipenem, panipenem, biapenem), cephems (ceftriaxone, cefotaxime), ampicillin and clarithromycin. The all MICs were determined by a broth micro dilution method or an agar dilution method according to CLSI. The MIC90(s) of DRPM against S. pneumoniae and H. influenzae from children were 0.25 microg/mL, 1 microg/mL, respectively, which were similar to strains from adults. These results suggested that antibacterial activity of DRPM is not variable by patient's age. DRPM also showed excellent activities against H. influenzae type b, L. monocytogenes and N. meningitidis, which cause purulent meningitis, and B. pertussis causing whooping cough more than the other carbapenems. DRPM showed superior activities against serious strains of pediatric infection diseases.
Pharmacological identification of a novel Ca2+ channel in chicken brain synaptosomes.
Lundy, P M; Hamilton, M G; Frew, R
1994-04-18
Ca2+ influx was measured in rat and chicken brain synaptosomes in the presence of a number of pharmacological tools which have recently been used to define voltage-sensitive Ca(2+)-channel (VSCC) types. In chicken brain synaptosomes. VSCCs which, because of their sensitivity to inhibition by omega-conotoxin (omega-CgTx), are thought to be exclusively N-type, the P-type VSCC polyamine inhibitor FTX (from Agelenopsis aperta venom; 1 microliters/ml), its synthetic analogue, sFTX (1-5 mM) and the polypeptides AgaIVA (IC50 0.29 microM) and omega-CgTx MVIIC (IC50 0.0022 microM) inhibited 70-100% of the measurable K+ stimulated Ca2+ influx. The prototypical N-channel VSCC inhibitor omega-CgTx GVIA (IC50 0.014 microM), Cd2+ (50 microM) and diluted venom from Hololena curta (1:2,500) also caused complete or almost complete, inhibition of Ca2+ influx. In comparable studies using rat brain synaptosomes, sFTX (1-10 mM) caused a dose-dependent reduction of Ca2+ influx, while FTX (1 microliters/ml) and AgaIVA (IC50 0.02 microM) completely inhibited Ca2+ influx. Similar to the findings in chicken synaptosomes, Cd2+ (50 microM) and H. curta (1:2,500 dilution) both inhibited K+ stimulated influx by > 80% whereas omega-CgTx (1 microM) only caused a maximum 25% inhibition. Both sFTX and its congener spermine, inhibited [125I]omega-CgTx binding to rat and chicken synaptosomal membranes. These results strongly implicate P-type channels as the major VSCC in rat brain. The results also clearly demonstrate a heretofore unrecognized, novel, FTX/AgaIVA/omega-CgTx GVIA/omega-CgTx MVIIC-sensitive VSCC in chicken brain.
NASA Astrophysics Data System (ADS)
Biagioli, Madeleine; Dinic, Jelena; Jimenez, Leidy Nallely; Sharma, Vivek
Free surface flows and drop formation processes present in printing, jetting, spraying, and coating involve the development of columnar necks that undergo spontaneous surface-tension driven instability, thinning, and pinch-off. Stream-wise velocity gradients that arise within the thinning neck create and extensional flow field, which induces micro-structural changes within complex fluids that contribute elastic stresses, changing the thinning and pinch-off dynamics. In this contribution, we use dripping-onto-substrate (DoS) extensional rheometry technique for visualization and analysis of the pinch-off dynamics of dilute and ultra-dilute aqueous polyethylene oxide (PEO) solutions. Using a range of molecular weights, we study the effect of both elasticity and finite extensibility. Both effective relaxation time and the transient extensional viscosity are found to be strongly concentration-dependent even for highly dilute solutions.
Shi, C; Gao, S; Gun, S
1997-06-01
The sample is digested with 6% NaOH solution and an amount of 50 microl is used for protein content analysis by the method of Comassie Brilliant Blue G250, the residual is diluted with equal 0.4% Lathanurm-EDTA solution. Its Calcium magensium and potassium content are determined by AAS. With quick-pulsed nebulization technique. When a self-made micro-sampling device is used, 20microl of sample volume is needed and it is only the 1/10 approximately 1/20 of the sample volume required for conventional determination. Sensitivity, precision and rate of recovery agree well with those using regular wet ashing method.
Rainville, Paul D; Simeone, Jennifer L; Root, Dan S; Mallet, Claude R; Wilson, Ian D; Plumb, Robert S
2015-03-21
The emergence of micro sampling techniques holds great potential to improve pharmacokinetic data quality, reduce animal usage, and save costs in safety assessment studies. The analysis of these samples presents new challenges for bioanalytical scientists, both in terms of sample processing and analytical sensitivity. The use of two dimensional LC/MS with, at-column-dilution for the direct analysis of highly organic extracts prepared from biological fluids such as dried blood spots and plasma is demonstrated. This technique negated the need to dry down and reconstitute, or dilute samples with water/aqueous buffer solutions, prior to injection onto a reversed-phase LC system. A mixture of model drugs, including bromhexine, triprolidine, enrofloxacin, and procaine were used to test the feasibility of the method. Finally an LC/MS assay for the probe pharmaceutical rosuvastatin was developed from dried blood spots and protein-precipitated plasma. The assays showed acceptable recovery, accuracy and precision according to US FDA guidelines. The resulting analytical method showed an increase in assay sensitivity of up to forty fold as compared to conventional methods by maximizing the amount loaded onto the system and the MS response for the probe pharmaceutical rosuvastatin from small volume samples.
Effective elastic moduli of triangular lattice material with defects
NASA Astrophysics Data System (ADS)
Liu, Xiaoyu; Liang, Naigang
2012-10-01
This paper presents an attempt to extend homogenization analysis for the effective elastic moduli of triangular lattice materials with microstructural defects. The proposed homogenization method adopts a process based on homogeneous strain boundary conditions, the micro-scale constitutive law and the micro-to-macro static operator to establish the relationship between the macroscopic properties of a given lattice material to its micro-discrete behaviors and structures. Further, the idea behind Eshelby's equivalent eigenstrain principle is introduced to replace a defect distribution by an imagining displacement field (eigendisplacement) with the equivalent mechanical effect, and the triangular lattice Green's function technique is developed to solve the eigendisplacement field. The proposed method therefore allows handling of different types of microstructural defects as well as its arbitrary spatial distribution within a general and compact framework. Analytical closed-form estimations are derived, in the case of the dilute limit, for all the effective elastic moduli of stretch-dominated triangular lattices containing fractured cell walls and missing cells, respectively. Comparison with numerical results, the Hashin-Shtrikman upper bounds and uniform strain upper bounds are also presented to illustrate the predictive capability of the proposed method for lattice materials. Based on this work, we propose that not only the effective Young's and shear moduli but also the effective Poisson's ratio of triangular lattice materials depend on the number density of fractured cell walls and their spatial arrangements.
Gu, Yongchuan; Wilson, William R
2009-10-01
PR-104 is a dinitrobenzamide mustard currently in clinical trial as a hypoxia-activated prodrug. It is converted systemically to the corresponding alcohol, PR-104A, which is activated by nitroreduction to the hydroxylamine (PR-104H) and amine (PR-104M). PR-104A is also metabolised to the O-glucuronide (PR-104G), and by oxidative debromoethylation to the semi-mustard PR-104S. We now report a validated ultra-high-pressure liquid chromatography and tandem mass spectrometry (UHPLC-MS/MS) method for the determination of these metabolites in human plasma. Plasma proteins were precipitated with acidified methanol and the supernatant diluted into water. Aliquots were analysed by UHPLC-MS/MS using a Zorbax Eclipse XDB-C18 Rapid Resolution HT (50mmx2.1mm, 1.8microm) column and gradient of acetonitrile and 0.01% formic acid with a 6min run time. The method had a linear range of 0.1-50microM for PR-104, PR-104A and PR-104G, 0.05-5microM for PR-104H, 0.025-2.5microM for PR-104M and 0.01-1microM for PR-104S. The intra-day and inter-day precision and accuracy were within 14%. The extraction recovery of all analytes was over 87%. The validated method was illustrated by using it to study the pharmacokinetics of PR-104 and its metabolites in a human patient.
Chariandy, C M; Seaforth, C E; Phelps, R H; Pollard, G V; Khambay, B P
1999-03-01
Antibacterial activity in 51 extracts from 29 plant species currently used in traditional medicine in Trinidad and the neighbouring Caribbean islands was tested for by the agar dilution streak method using six bacteria: Escherichia coli, Pseudomonas aeruginosa. Salmonella tophimurium, Staphylococcus aureus, Staphylococcus epidermidis and Enterococcus faecalis. The extracts from eight of the plants tested showed significant activity against one or more micro-organisms and the most susceptible bacterium was Staphylococcus aureus. In the bioassays for toxicity towards the Aedes aegypti mosquito the most effective plant extracts were from Justicia pectoralis, Manihot utilissima and Stachytarpheta jamaicensis.
Aqueous Ethanol Ignition and Engine Studies, Phase I
DOT National Transportation Integrated Search
2010-09-01
Our objectives were to design a micro-dilution tunnel for monitoring engine emissions, measure ignition temperature and heat release from ethanol-water-air mixtures on platinum, and initiate a computational fluid dynamics model of a catalytic igniter...
Genzel, Yvonne; König, Susanne; Reichl, Udo
2004-12-01
The direct separation detection of amino acids by anion exchange chromatography with integrated pulsed amperometric detection was optimized for the analysis of typical mammalian cell culture broth samples. Existing gradient elution conditions were adapted, considering the additions of peptone (2 g/L) and 10 vol% fetal calf serum to the medium as well as changing concentrations of glucose from 5.5 g/L up to complete consumption. Samples had to be analyzed in two dilutions with water (1:33.3 and 1:200) due to the strongly varying amino acid concentrations in the samples as a result of the medium composition and cell metabolism. The method was validated in a linear working range for the most common amino acids (2.5-7.5 and 1.25-3.75 microM for cystine/cysteine with 15 microl injection volume). The relative standard deviation of the method for all amino acids was less than 5%, with detection limits of less than 0.6 microM and quantitation limits of less than 1.6 microM. As an example, data for the amino acid composition of different media used for the production of inactivated influenza vaccines in cell culture are shown.
Diagnostic efficacy of cell block method for vitreoretinal lymphoma.
Kase, Satoru; Namba, Kenichi; Iwata, Daiju; Mizuuchi, Kazuomi; Kitaichi, Nobuyoshi; Tagawa, Yoshiaki; Okada-Kanno, Hiromi; Matsuno, Yoshihiro; Ishida, Susumu
2016-03-17
Vitreoretinal lymphoma (VRL) is a life- and sight-threatening disorder. The aim of this study was to analyze the usefulness of the cell block method for diagnosis of VRL. Sixteen eyes in 12 patients with VRL, and 4 eyes in 4 patients with idiopathic uveitis presenting with vitreous opacity were enrolled in this study. Both undiluted vitreous and diluted fluids were isolated during micro-incision vitrectomy. Cell block specimens were prepared in 19 eyes from diluted fluid containing shredding vitreous. These specimens were then submitted for HE staining as well as immunocytological analyses with antibodies against the B-cell marker CD20, the T-cell marker CD3, and cell proliferation marker Ki67. Conventional smear cytology was applied in 14 eyes with VRL using undiluted vitreous samples. The diagnosis of VRL was made based on the results of cytology, concentrations of interleukin (IL)-10 and IL-6 in undiluted vitreous, and immunoglobulin heavy chain gene rearrangement analysis. Atypical lymphoid cells were identified in 14 out of 15 cell block specimens of VRL (positive rate: 93.3 %), but in 5 out of 14 eyes in conventional smear cytology (positive rate: 35.7 %). Atypical lymphoid cells showed immunoreactivity for CD20 and Ki67. Seven cell block specimens were smear cytology-negative and cell block-positive. The cell block method showed no atypical lymphoid cells in any patient with idiopathic uveitis. Cell block specimens using diluted vitreous fluid demonstrated a high diagnostic sensitivity and a low pseudo-positive rate for the cytological diagnosis of VRL. The cell block method contributed to clear differentiation between VRL and idiopathic uveitis with vitreous opacity.
"Micro to macro (M2M)"--A novel approach for intravenous delivery of propofol.
Damitz, Robert; Chauhan, Anuj
2015-10-15
Propofol emulsions have limited shelf life and safety concerns for injection. Microemulsions of propofol are thermodynamically stable and simpler to manufacture, but cause additional pain on injection. We propose a novel micro to macro (M2M) approach of destabilizing a microemulsion immediately prior to injection. Microemulsions of propofol were prepared at two to three times the drug loadings of commercial formulations. We determined suitable microemulsion compositions which destabilize into macroemulsions after two or three fold dilutions with water. Droplet growth after dilution was measured with dynamic light scattering. Increasing solution turbidity after dilution was also measured optically with millisecond resolution. Experimental data was analyzed in the context of a coalescence model. Microemulsions rapidly coalesce into larger droplet size macroemulsions after dilution according to the phase diagram shift. The resulting macroemulsions are metastable retaining their droplet size for several hours. Droplet growth occurs on the order of seconds and a metastable size of about 1 micron is reached in minutes. Rates of droplet growth and metastable droplet sizes depend on the surfactant composition. The coalescence model predicts droplet growth with good agreement but only after accounting for the finite probability of coalescence from each collision. The M2M concept has been demonstrated for the anesthetic drug propofol which may improve stability and manufacturability in addition to reducing pain on injection. This approach could be adapted to other hydrophobic vesicant drugs as well. Copyright © 2015 Elsevier B.V. All rights reserved.
Diemer, J; Quétel, C R; Taylor, P D P
2002-09-01
The contribution of the Institute for Reference Materials and Measurements to the certification of the B, Cd, Cu, Mg, and Pb content of a synthetic water sample used in Comparison 12 of the International Measurement Evaluation Programme (IMEP-12) is described. The aim of the IMEP programme is to demonstrate objectively the degree of equivalence and quality of chemical measurements of individual laboratories on the international scene by comparing them with reference ranges traceable to the SI (Système International d'Unités). IMEP is organized in support of European Union policies and helps to improve the traceability of values produced by field chemical measurement laboratories. The analytical procedure used to establish the reference values for the B, Cd, Cu, Mg, and Pb content of the IMEP-12 sample is based on inductively coupled plasma-isotope-dilution mass spectrometry (ICP-IDMS) applied as a primary method of measurement. The measurements performed for the IMEP-12 study are described in detail. Focus is on the element boron, which is particularly difficult to analyze by ICP-MS because of potential problems of low sensitivity, high mass discrimination, memory effects, and abundance sensitivity. For each of the certified amount contents presented here a total uncertainty budget was calculated using the method of propagation of uncertainties according to ISO (International Organization for Standardization) and Eurachem guidelines. For all investigated elements with concentrations in the low micro g kg(-1) and mg kg(-1) range (corresponding to pmol kg(-1) to the high micro mol kg(-1) level), SI-traceable reference values with relative expanded uncertainties ( k=2) of less than 2 % were obtained.
Casas, Vanessa; Llompart, Maria; García-Jares, Carmen; Cela, Rafael; Dagnac, Thierry
2006-08-18
A method based on solid-phase microextraction (SPME) and gas chromatography with micro-electron capture detection (GC-microECD) has been optimized for the analysis of pyrethroids in water samples. The influence of parameters such as temperature, fibre coating, salting-out effect and sampling mode on the extraction efficiency has been studied by means of a mix-level factorial design, which allowed the study of main effects as well as two factor interactions. Finally, a method based on direct SPME at 50 degrees C, using polydimethylsiloxane fibre is proposed. The method showed good linearity (R2>0.995) and repeatability (RSD
The kinetics of the oxidation of cytochrome c by Paracoccus cytochrome c peroxidase.
Gilmour, R; Goodhew, C F; Pettigrew, G W; Prazeres, S; Moura, J J; Moura, I
1994-06-15
In work that is complementary to our investigation of the spectroscopic features of the cytochrome c peroxidase from Paracoccus denitrificans [Gilmour, Goodhew, Pettigrew, Prazeres, Moura and Moura (1993) Biochem. J. 294, 745-752], we have studied the kinetics of oxidation of cytochrome c by this enzyme. The enzyme, as isolated, is in the fully oxidized form and is relatively inactive. Reduction of the high-potential haem at pH 6 with ascorbate results in partial activation of the enzyme. Full activation is achieved by addition of 1 mM CaCl2. Enzyme activation is associated with formation of a high-spin state at the oxidized low-potential haem. EGTA treatment of the oxidized enzyme prevents activation after reduction with ascorbate, while treatment with EGTA of the reduced, partially activated, form abolishes the activity. We conclude that the active enzyme is a mixed-valence form with the low-potential haem in a high-spin state that is stabilized by Ca2+. Dilution of the enzyme results in a progressive loss of activity, the extent of which depends on the degree of dilution. Most of the activity lost upon dilution can be recovered after reconcentration. The M(r) of the enzyme on molecular-exclusion chromatography is concentration-dependent, with a shift to lower values at lower concentrations. Values of M(r) obtained are intermediate between those of a monomer (39,565) and a dimer. We propose that the active form of the enzyme is a dimer which dissociates at high dilution to give inactive monomers. From the activity of the enzyme at different dilutions, a KD of 0.8 microM can be calculated for the monomerdimer equilibrium. The cytochrome c peroxidase oxidizes horse ferrocytochrome c with first-order kinetics, even at high ferrocytochrome c concentrations. The maximal catalytic-centre activity ('turnover number') under the assay conditions used is 62,000 min-1, with a half-saturating ferrocytochrome c concentration of 3.3 microM. The corresponding values for the Paracoccus cytochrome c-550 (presumed to be the physiological substrate) are 85,000 min-1 and 13 microM. However, in this case, the kinetics deviate from first-order progress curves at all ferrocytochrome c concentrations. Consideration of the periplasmic environment in Paracoccus denitrificans leads us to propose that the enzyme will be present as the fully active dimer supplied with saturating ferrocytochrome c-550.
Keevil, B G; Owen, L; Thornton, S; Kavanagh, J
2005-09-01
Measurement of urine citrate is used to assess the risk of further urinary stone formation and to assess the benefit of treatment in affected individuals. We wanted to develop a simple and rapid liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the analysis of urinary citrate and to compare it with our current enzymatic assay. For the LC-MS/MS assay, samples were prepared in a deep-well block by adding 10 microL of urine and 20 microL of internal standard to 400 microL of water. After mixing, 3 microL of the diluted sample was injected into the LC-MS/MS system. An LC system was used to isocratically elute a C18 column (50 x 2.1 mm) with 0.4 mL/min water containing 2 mmol/L ammonium acetate and 0.1% (v/v) formic acid. A step gradient of 100% methanol containing 2 mmol/L ammonium acetate and 0.1% (v/v) formic acid was used to wash the column. The retention times were 1.4 min for citrate and 1.4 min for d4-citrate. Cycle time was 4.0 min, injection to injection. The analytes were monitored using a tandem mass spectrometer operated in multiple reaction monitoring mode using the following transitions, citrate m/z 191.0>111.0 and d4-citrate m/z 195.0>113.0. Within and between-batch coefficients of variation were <3% over the range 480-3800 micromol/L. The lower limit of quantification was 24.0 micromol/L. Regression analysis showed LC-MS/MS = 0.8781 (enzymatic assay) + 102.5, r = 0.964, n = 73. We have developed a simple LC-MS/MS method for urinary citrate measurement that shows acceptable performance.
NASA Astrophysics Data System (ADS)
Dey, Arka; Das, Mrinmay; Datta, Joydeep; Jana, Rajkumar; Dhar, Joydeep; Sil, Sayantan; Biswas, Debasish; Banerjee, Chandan; Ray, Partha Pratim
2016-07-01
Here we have presented the results of large area (30 × 30 cm2) silicon-hydrogen alloy material and solar cell by argon dilution method. As an alternative to hydrogen dilution, argon dilution method has been applied to develop single junction solar cell with appreciable stability. Optimization of deposition conditions revealed that 95% argon dilution gives a nanostructured material with improved transport property and less light induced degradation. The minority carrier diffusion length (L d ) and mobility-lifetime (μτ) product of the material with 95% argon dilution degrades least after light soaking. Also the density of states (DOS) below conduction level reveals that this material is less defective. Solar cell with this argon diluted material has been fabricated with all the layers deposited by argon dilution method. Finally we have compared the argon diluted solar cell results with the optimized hydrogen diluted solar cell. Light soaking study proves that it is possible to develop stable solar cell on large area by argon dilution method and that the degradation of argon diluted solar cell is less than that of hydrogen diluted one. [Figure not available: see fulltext.
Nischkauer, Winfried; Vanhaecke, Frank; Limbeck, Andreas
2016-08-01
We present a technique for the fast screening of the lead concentration in whole blood samples using laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS). The whole blood sample is deposited on a polymeric surface and wiped across a set of micro-grooves previously engraved into the surface. The engraving of the micro-grooves was accomplished with the same laser system used for LA-ICP-MS analysis. In each groove, a part of the liquid blood is trapped, and thus, the sample is divided into sub-aliquots. These aliquots dry quasi instantly and are then investigated by means of LA-ICP-MS. For quantification, external calibration against aqueous standard solutions was relied on, with iron as an internal standard to account for varying volumes of the sample aliquots. The (208)Pb/(57)Fe nuclide ratio used for quantification was obtained via a data treatment protocol so far only used in the context of isotope ratio determination involving transient signals. The method presented here was shown to provide reliable results for Recipe ClinChek® Whole Blood Control levels I-III (nos. 8840-8842), with a repeatability of typically 3 % relative standard deviation (n = 6, for Pb at 442 μg L(-1)). Spiked and non-spiked real whole blood was analysed as well, and the results were compared with those obtained via dilution and sectorfield ICP-MS. A good agreement between both methods was observed. The detection limit (3 s) for lead in whole blood was established to be 10 μg L(-1) for the laser ablation method presented here. Graphical Abstract Micro-grooves are filled with whole blood, dried, and analyzed by laser ablation ICP-mass spectrometry. Notice that the laser moves in perpendicular direction with regard to the micro-grooves.
Verifying mixing in dilution tunnels How to ensure cookstove emissions samples are unbiased
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wilson, Daniel L.; Rapp, Vi H.; Caubel, Julien J.
A well-mixed diluted sample is essential for unbiased measurement of cookstove emissions. Most cookstove testing labs employ a dilution tunnel, also referred to as a “duct,” to mix clean dilution air with cookstove emissions before sampling. It is important that the emissions be well-mixed and unbiased at the sampling port so that instruments can take representative samples of the emission plume. Some groups have employed mixing baffles to ensure the gaseous and aerosol emissions from cookstoves are well-mixed before reaching the sampling location [2, 4]. The goal of these baffles is to to dilute and mix the emissions stream withmore » the room air entering the fume hood by creating a local zone of high turbulence. However, potential drawbacks of mixing baffles include increased flow resistance (larger blowers needed for the same exhaust flow), nuisance cleaning of baffles as soot collects, and, importantly, the potential for loss of PM2.5 particles on the baffles themselves, thus biasing results. A cookstove emission monitoring system with baffles will collect particles faster than the duct’s walls alone. This is mostly driven by the available surface area for deposition by processes of Brownian diffusion (through the boundary layer) and turbophoresis (i.e. impaction). The greater the surface area available for diffusive and advection-driven deposition to occur, the greater the particle loss will be at the sampling port. As a layer of larger particle “fuzz” builds on the mixing baffles, even greater PM2.5 loss could occur. The micro structure of the deposited aerosol will lead to increased rates of particle loss by interception and a tendency for smaller particles to deposit due to impaction on small features of the micro structure. If the flow stream could be well-mixed without the need for baffles, these drawbacks could be avoided and the cookstove emissions sampling system would be more robust.« less
2008-03-01
slips was first coated with a detergent wash. Commercially available Ivory soap shavings were diluted with sterile Millipore® water in a...environments. This removed controllable variability between the Bacillus species and increased the confidence in continued use of such surrogacy
Novel method to detect microRNAs using chip-based QuantStudio 3D digital PCR.
Conte, Davide; Verri, Carla; Borzi, Cristina; Suatoni, Paola; Pastorino, Ugo; Sozzi, Gabriella; Fortunato, Orazio
2015-10-23
Research efforts for the management of cancer, in particular for lung cancer, are directed to identify new strategies for its early detection. MicroRNAs (miRNAs) are a new promising class of circulating biomarkers for cancer detection, but lack of consensus on data normalization methods has affected the diagnostic potential of circulating miRNAs. There is a growing interest in techniques that allow an absolute quantification of miRNAs which could be useful for early diagnosis. Recently, digital PCR, mainly based on droplets generation, emerged as an affordable technology for precise and absolute quantification of nucleic acids. In this work, we described a new interesting approach for profiling circulating miRNAs in plasma samples using a chip-based platform, the QuantStudio 3D digital PCR. The proposed method was validated using synthethic oligonucleotide at serial dilutions in plasma samples of lung cancer patients and in lung tissues and cell lines. Given its reproducibility and reliability, our approach could be potentially applied for the identification and quantification of miRNAs in other biological samples such as circulating exosomes or protein complexes. As chip-digital PCR becomes more established, it would be a robust tool for quantitative assessment of miRNA copy number for diagnosis of lung cancer and other diseases.
Plant Growth Biostimulants Based on Different Methods of Seaweed Extraction with Water.
Godlewska, Katarzyna; Michalak, Izabela; Tuhy, Łukasz; Chojnacka, Katarzyna
2016-01-01
We explored two methods for obtaining aqueous extracts: boiling and soaking of Baltic seaweeds (EB and ES, resp.). Algal extracts were characterized in terms of polyphenols, micro- and macroelements, lipids content, and antibacterial properties. The utilitarian properties were examined in the germination tests on Lepidium sativum for three extract dilutions (0.5, 2.5, and 10%). It was found that the extracts were similar in micro- and macroelement concentrations. Water was proved to be a good solvent to extract phenolic compounds. The algal extract produced by soaking biomass did not show inhibitory effect on Escherichia coli and Staphylococcus aureus. Only the boiled extract had an inhibitory activity against E. coli. Germination tests revealed a positive influence of the bioproducts on the cultivated plants. In the group treated with 10% EB, plants were 13% longer than in the control group; the content of elements B, Mo, Zn, and Na in the group treated with 10% ES was higher by 76%, 48%, 31%, and 59% than in the control group, respectively; the content of chlorophyll was 2.5 times higher in 0.5% ES than in the control group. Extracts showed the slight impact on the morphology of plants.
Plant Growth Biostimulants Based on Different Methods of Seaweed Extraction with Water
Godlewska, Katarzyna; Tuhy, Łukasz; Chojnacka, Katarzyna
2016-01-01
We explored two methods for obtaining aqueous extracts: boiling and soaking of Baltic seaweeds (EB and ES, resp.). Algal extracts were characterized in terms of polyphenols, micro- and macroelements, lipids content, and antibacterial properties. The utilitarian properties were examined in the germination tests on Lepidium sativum for three extract dilutions (0.5, 2.5, and 10%). It was found that the extracts were similar in micro- and macroelement concentrations. Water was proved to be a good solvent to extract phenolic compounds. The algal extract produced by soaking biomass did not show inhibitory effect on Escherichia coli and Staphylococcus aureus. Only the boiled extract had an inhibitory activity against E. coli. Germination tests revealed a positive influence of the bioproducts on the cultivated plants. In the group treated with 10% EB, plants were 13% longer than in the control group; the content of elements B, Mo, Zn, and Na in the group treated with 10% ES was higher by 76%, 48%, 31%, and 59% than in the control group, respectively; the content of chlorophyll was 2.5 times higher in 0.5% ES than in the control group. Extracts showed the slight impact on the morphology of plants. PMID:27366749
A simple HPLC method for simultaneous determination of lopinavir, ritonavir and efavirenz.
Usami, Yoshiko; Oki, Tsuyoshi; Nakai, Masahiko; Sagisaka, Masafumi; Kaneda, Tsuguhiro
2003-06-01
We developed a simple HPLC method for the simultaneous determination of lopinavir (LPV), ritonavir (RTV) and efavirenz (EFV) to evaluate the efficiency of co-administration of LPV/RTV and EFV in Japanese patients enrolled in a clinical study. The monitoring of LPV plasma concentration is important because co-administration of LPV/RTV with EFV sometimes decreases plasma concentrations of LPV caused by EFV activation of cytochrome P-450 3A. A solution of acetonitrile, methanol and tetramethylammonium perchlorate (TMAP) in dilute aqueous trifluoroacetic acid (TFA) has been used as the mobile phase in a HPLC method to elute LPV and RTV. We found that a solvent ratio of 45 : 5 : 50 (v/v/v) of acetonitrile/methanol/0.02 M TMAP in 0.2% TFA optimized separation of LPV, RTV and EFV. A column temperature of 30 degrees C was necessary for the reproducibility of the analyses. Standard curves were linear in the range 0.060 to 24.06 micro g/ml for LPV, 0.010 to 4.16 micro g/ml for RTV, and 0.047 to 37.44 micro g/ml for EFV. Coefficients of variation (CVs) of LPV, RTV and EFV in intraday and interday assays ranged from 1.5 to 4.0%, 2.5 to 16.8% and 1.0 to 7.7%, respectively. Accuracies ranged from 100 to 110%, 101 to 116% and 99 to 106% for LPV, RTV and EFV, respectively. The extraction recoveries were 77-87, 77-83 and 81-91% for LPV, RTV and EFV, respectively.
Backe, Will J; Day, Thomas C; Field, Jennifer A
2013-05-21
A new analytical method was developed to quantify 26 newly-identified and 21 legacy (e.g. perfluoroalkyl carboxylates, perfluoroalkyl sulfonates, and fluorotelomer sulfonates) per and polyfluorinated alkyl substances (PFAS) in groundwater and aqueous film forming foam (AFFF) formulations. Prior to analysis, AFFF formulations were diluted into methanol and PFAS in groundwater were micro liquid-liquid extracted. Methanolic dilutions of AFFF formulations and groundwater extracts were analyzed by large-volume injection (900 μL) high-performance liquid chromatography tandem mass spectrometry. Orthogonal chromatography was performed using cation exchange (silica) and anion exchange (propylamine) guard columns connected in series to a reverse-phase (C18) analytical column. Method detection limits for PFAS in groundwater ranged from 0.71 ng/L to 67 ng/L, and whole-method accuracy ranged from 96% to 106% for analytes for which matched authentic analytical standards were available. For analytes without authentic analytical standards, whole-method accuracy ranged from 78 % to 144 %, and whole-method precision was less than 15 % relative standard deviation for all analytes. A demonstration of the method on groundwater samples from five military bases revealed eight of the 26 newly-identified PFAS present at concentrations up to 6900 ng/L. The newly-identified PFAS represent a minor fraction of the fluorinated chemicals in groundwater relative to legacy PFAS. The profiles of PFAS in groundwater differ from those found in fluorotelomer- and electrofluorination-based AFFF formulations, which potentially indicates environmental transformation of PFAS.
Sienkiewicz, Monika; Łysakowska, Monika; Kowalczyk, Edward; Szymańska, Grażyna; Kochan, Ewa; Krukowska, Jolanta; Olszewski, Jurek; Zielińska-Bliźniewska, Hanna
2017-03-01
The aim of this work was to characterize the ability of essential oils to support antibiotics against pathogenic bacteria in wounds. Gram-positive and Gram-negative bacteria obtained from wound infections were identified according to standard microbiological methods. Essential oils were analysed by GC-FID-MS. The susceptibility of bacteria to antibiotics, essential oils and their combination was assessed using the disc-diffusion method. The Minimal Inhibitory Concentration and Minimum Bactericidal Concentration of the essential oils were established by the micro-dilution broth method. Although cinnamon, clove, thyme and lavender essential oils were found to have the greatest antibacterial activity when used alone, the greatest additive and synergistic effects against pathogenic wound bacteria in combination with recommended antibiotics were demonstrated by basil, clary sage and rosemary oils. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.
NASA Astrophysics Data System (ADS)
Jia, Kun; Mei, Deqing; Meng, Jianxin; Yang, Keji
2014-10-01
Ultrasonic manipulation has become an attractive method for surface-sensitive objects in micro-technology. Related phenomena, such as radiation force, multiple scattering, and acoustic streaming, have been widely studied. However, in current studies, the behavior of micro-particles in potential force fields is always analyzed in a quasi-static manner. We developed a dynamic model of a dilute micro-particle in the commonly used two-dimensional ultrasonic manipulation system to provide a systemic and quantitative analysis of the transient properties of particle movement. In this model, the acoustic streaming and hydrodynamic forces, omitted in previous work, were both considered. The trajectory of a spherical silica particle with different initial conditions was derived by numerically solving the established nonlinear differential integral equation system, which was then validated experimentally. The envelope of the experimental data on the x-axis showed good agreement with the theoretical calculation, and the greater influence on the y-axis of the deviation between the actual sound field and the ideal distribution employed in our dynamic model could account for the differences in displacement in that direction. Finally, the influence of particle size on its movement and the effect of acoustic streaming on calculating the hydrodynamic forces for an isolated particle with motion relative to the fluid were analyzed theoretically. It was found that the ultrasonic manipulation system will translate from an under-damped system to an over-damped system with a decrease in particle size and the micro-scale acoustic streaming velocity was negligible when calculating the hydrodynamic forces on the particle in the ultrasonic manipulation system.
False positives in Biolog EcoPlates™ and MT2 MicroPlates™ caused by calcium.
Pierce, Melissa L; Ward, J Evan; Dobbs, Fred C
2014-02-01
Biolog MicroPlates(TM) (e.g. EcoPlate(TM), MT2 MicroPlate(TM), GN MicroPlate(TM)) are useful tools for characterizing microbial communities, providing community-level physiological profiles to terrestrial and aquatic ecologists. The more recently designed Biolog EcoPlates have been used frequently in aquatic ecology with success. This study, however, reveals one major problem when using EcoPlates to evaluate samples within an estuarine or seawater matrix. At concentrations greater than 100 parts per million, the cation calcium begins to interfere with the microplate chemistry, causing false positive readings. Experiments, in which multiple treatments of natural and artificial seawater were tested, as well as calcium-addition experiments, demonstrate that calcium inhibits complete dissolution of the minimal growth medium in wells. Future studies involving Biolog EcoPlates and MicroPlates should take this effect into account, and the dilution of samples is strongly recommended to diminish the "calcium effect." Copyright © 2013 Elsevier B.V. All rights reserved.
Total body water and lean body mass estimated by ethanol dilution
NASA Technical Reports Server (NTRS)
Loeppky, J. A.; Myhre, L. G.; Venters, M. D.; Luft, U. C.
1977-01-01
A method for estimating total body water (TBW) using breath analyses of blood ethanol content is described. Regression analysis of ethanol concentration curves permits determination of a theoretical concentration that would have existed if complete equilibration had taken place immediately upon ingestion of the ethanol; the water fraction of normal blood may then be used to calculate TBW. The ethanol dilution method is applied to 35 subjects, and comparison with a tritium dilution method of determining TBW indicates that the correlation between the two procedures is highly significant. Lean body mass and fat fraction were determined by hydrostatic weighing, and these data also prove compatible with results obtained from the ethanol dilution method. In contrast to the radioactive tritium dilution method, the ethanol dilution method can be repeated daily with its applicability ranging from diseased individuals to individuals subjected to thermal stress, strenuous exercise, water immersion, or the weightless conditions of space flights.
Chan, Wan; Chen, Bingzi; Wang, Lianrong; Taghizadeh, Koli; Demott, Michael S; Dedon, Peter C
2010-05-05
The oxidation of 2-deoxyribose in DNA has emerged as a critical determinant of the cellular toxicity of oxidative damage to DNA, with oxidation of each carbon producing a unique spectrum of electrophilic products. We have developed and validated an isotope-dilution gas chromatography-coupled mass spectrometry (GC-MS) method for the rigorous quantification of two major 2-deoxyribose oxidation products: the 2-deoxyribonolactone abasic site of 1'-oxidation and the nucleoside 5'-aldehyde of 5'-oxidation chemistry. The method entails elimination of these products as 5-methylene-2(5H)-furanone (5MF) and furfural, respectively, followed by derivatization with pentafluorophenylhydrazine (PFPH), addition of isotopically labeled PFPH derivatives as internal standards, extraction of the derivatives, and quantification by GC-MS analysis. The precision and accuracy of the method were validated with oligodeoxynucleotides containing the 2-deoxyribonolactone and nucleoside 5'-aldehyde lesions. Further, the well-defined 2-deoxyribose oxidation chemistry of the enediyne antibiotics, neocarzinostatin and calicheamicin gamma(1)(I), was exploited in control studies, with neocarzinostatin producing 10 2-deoxyribonolactone and 300 nucleoside 5'-aldehyde per 10(6) nt per microM in accord with its established minor 1'- and major 5'-oxidation chemistry. Calicheamicin unexpectedly caused 1'-oxidation at a low level of 10 2-deoxyribonolactone per 10(6) nt per microM in addition to the expected predominance of 5'-oxidation at 560 nucleoside 5'-aldehyde per 10(6) nt per microM. The two hydroxyl radical-mediated DNA oxidants, gamma-radiation and Fe(2+)-EDTA, produced nucleoside 5'-aldehyde at a frequency of 57 per 10(6) nt per Gy (G-value 74 nmol/J) and 3.5 per 10(6) nt per microM, respectively, which amounted to 40% and 35%, respectively, of total 2-deoxyribose oxidation as measured by a plasmid nicking assay. However, gamma-radiation and Fe(2+)-EDTA produced different proportions of 2-deoxyribonolactone at 7% and 24% of total 2-deoxyribose oxidation, respectively, with frequencies of 10 lesions per 10(6) nt per Gy (G-value, 13 nmol/J) and 2.4 lesions per 10(6) nt per microM. Studies in TK6 human lymphoblastoid cells, in which the analytical data were corrected for losses sustained during DNA isolation, revealed background levels of 2-deoxyribonolactone and nucleoside 5'-aldehyde of 9.7 and 73 lesions per 10(6) nt, respectively. Gamma-irradiation of the cells caused increases of 0.045 and 0.22 lesions per 10(6) nt per Gy, respectively, which represents a approximately 250-fold quenching effect of the cellular environment similar to that observed in previous studies. The proportions of the various 2-deoxyribose oxidation products generated by gamma-radiation are similar for purified DNA and cells. These results are consistent with solvent exposure as a major determinant of hydroxyl radical reactivity with 2-deoxyribose in DNA, but the large differences between gamma-radiation and Fe(2+)-EDTA suggest that factors other than hydroxyl radical reactivity govern DNA oxidation chemistry.
NASA Astrophysics Data System (ADS)
Korb, H.; Hoeft, A.; Hellige, G.
1984-10-01
Previous studies have shown that intramyocardial blood volume does not vary to a major extent even during extreme variation of hemodynamics and coronary vascular tone. Based on a constant intramyocardial blood volume it is therefore possible to calculate tissue blood flow from the mean transit time of an intravascular tracer. The purpose of this study was to develop a clinically applicable method for measurement of coronary blood flow. The new method was based on indocyanine green, a dye which is bound to albumin and intravasally detectable by means of a fiberoptic catheter device. One fiberoptic catheter was placed in the aortic root and another in the coronary sinus. After central venous dye injection the resulting arterial and coronary venous dye dilution curves were processed on-line by a micro-computer. The mean transit time as well as myocardial blood flow were calculated from the step response function of the deconvoluted arterial and coronary venous signals. Reference flow was determined with an extracorporeal electromagnetic flowprobe within a coronary sinus bypass system. 38 steady states with coronary blood flow ranging from 49 - 333 ml/min*100g were analysed in 5 dogs. Mean transit times varied from 2.9 to 16.6 sec. An average intracoronary blood volume of 13.9 -7 1.8 m1/100g was calculated. The correlation between flow determined by the dye dilution technique and flow measured with the reference method was 0.98. According to these results determination of coronary blood flow with a double fiberoptic system and indocyanine green should be possible even under clinical conditions. Furthermore, the arterial and coronary venous oxygen saturation can be monitored continuously by the fiberoptic catheters. Therefore, additional information about the performance of the heart such as myocardial oxygen consumption and myocardial efficiency is available with the same equipment.
2010-01-01
Background Use of essential oils for controlling Candida albicans growth has gained significance due to the resistance acquired by pathogens towards a number of widely-used drugs. The aim of this study was to test the antifungal activity of selected essential oils against Candida albicans in liquid and vapour phase and to determine the chemical composition and mechanism of action of most potent essential oil. Methods Minimum Inhibitory concentration (MIC) of different essential oils in liquid phase, assayed through agar plate dilution, broth dilution & 96-well micro plate dilution method and vapour phase activity evaluated through disc volatilization method. Reduction of C. albicans cells with vapour exposure was estimated by kill time assay. Morphological alteration in treated/untreated C. albicans cells was observed by the Scanning electron microscopy (SEM)/Atomic force microscopy (AFM) and chemical analysis of the strongest antifungal agent/essential oil has been done by GC, GC-MS. Results Lemon grass (Cymbopogon citratus) essential oil exhibited the strongest antifungal effect followed by mentha (Mentha piperita) and eucalyptus (Eucalyptus globulus) essential oil. The MIC of lemon grass essential oil in liquid phase (288 mg/l) was significantly higher than that in the vapour phase (32.7 mg/l) and a 4 h exposure was sufficient to cause 100% loss in viability of C. albicans cells. SEM/AFM of C. albicans cells treated with lemon grass essential oil at MIC level in liquid and vapour phase showed prominent shrinkage and partial degradation, respectively, confirming higher efficacy of vapour phase. GC-MS analysis revealed that lemon grass essential oil was dominated by oxygenated monoterpenes (78.2%); α-citral or geranial (36.2%) and β-citral or neral (26.5%), monoterpene hydrocarbons (7.9%) and sesquiterpene hydrocarbons (3.8%). Conclusion Lemon grass essential oil is highly effective in vapour phase against C. albicans, leading to deleterious morphological changes in cellular structures and cell surface alterations. PMID:21067604
Pujol, I; Guarro, J; Llop, C; Soler, L; Fernández-Ballart, J
1996-09-01
An evaluation of broth dilution antifungal susceptibility tests was performed by determining both the micro- and macrodilution MICs of amphotericin B, fluconazole, ketoconazole, 5-fluorocytosine, miconazole, and itraconazole against representative species of opportunistic hyphomycetes (Fusarium spp. and Cladosporium [Cladophialophora] spp.) and ascomycetes (Chaetomium spp.). A total of 78 strains were tested, the majority of them twice and some three times on different days. Both methods were performed according to the recommendations of the National Committee for Clinical Laboratory Standards (Document M27-P), with the exception of the temperature of incubation, which was 25 degrees C in our case. A spectrophotometric method for inoculum preparation, RPMI 1640 medium buffered with morpholinepropanesulfonic acid (pH 7.0), and an additive drug dilution procedure were used. The MICs obtained by the two methods were read after 48, 72, and 96 h of incubation for Fusarium spp. and after 72, 96, and 120 h for the remaining isolates. The kappa test was used to calculate the degree of agreement. Considering the three fungal groups together, a good agreement between the results of both tests was observed with almost all the drugs at the different incubation times. There were no cases of poor agreement. The highest level (kappa index = 1) was observed with ketoconazole at the second-day reading. These results support the further evaluation of the broth microdilution test as an alternative to the reference broth macrodilution susceptibility test.
Pujol, I; Guarro, J; Llop, C; Soler, L; Fernández-Ballart, J
1996-01-01
An evaluation of broth dilution antifungal susceptibility tests was performed by determining both the micro- and macrodilution MICs of amphotericin B, fluconazole, ketoconazole, 5-fluorocytosine, miconazole, and itraconazole against representative species of opportunistic hyphomycetes (Fusarium spp. and Cladosporium [Cladophialophora] spp.) and ascomycetes (Chaetomium spp.). A total of 78 strains were tested, the majority of them twice and some three times on different days. Both methods were performed according to the recommendations of the National Committee for Clinical Laboratory Standards (Document M27-P), with the exception of the temperature of incubation, which was 25 degrees C in our case. A spectrophotometric method for inoculum preparation, RPMI 1640 medium buffered with morpholinepropanesulfonic acid (pH 7.0), and an additive drug dilution procedure were used. The MICs obtained by the two methods were read after 48, 72, and 96 h of incubation for Fusarium spp. and after 72, 96, and 120 h for the remaining isolates. The kappa test was used to calculate the degree of agreement. Considering the three fungal groups together, a good agreement between the results of both tests was observed with almost all the drugs at the different incubation times. There were no cases of poor agreement. The highest level (kappa index = 1) was observed with ketoconazole at the second-day reading. These results support the further evaluation of the broth microdilution test as an alternative to the reference broth macrodilution susceptibility test. PMID:8878589
ERIC Educational Resources Information Center
Kamin, Lawrence
1996-01-01
Presents problems appropriate for high school and college students that highlight dilution methods. Promotes an understanding of dilution methods in order to prevent the unnecessary waste of chemicals and glassware in biology laboratories. (JRH)
Assadian, Ojan; Wehse, Katrin; Hübner, Nils-Olaf; Koburger, Torsten; Bagel, Simone; Jethon, Frank; Kramer, Axel
2011-01-01
Background: An in-vitro study was conducted investigating the antimicrobial efficacy of polihexanide and triclosan against clinical isolates and reference laboratory strains of Staphylococcus aureus and Escherichia coli. Methods: The minimal inhibitory concentration (MIC) and the minimal microbicidal concentration (MMC) were determined following DIN 58940-81 using a micro-dilution assay and a quantitative suspension test following EN 1040. Polihexanide was tested in polyethylene glycol 4000, triclosan in aqueous solutions. Results: Against all tested strains the MIC of polihexanide ranged between 1–2 µg/mL. For triclosan the MICs varied depending on strains ranging between 0.5 µg/mL for the reference strains and 64 µg/mL for two clinical isolates. A logRF >5 without and logRF >3 with 0.2% albumin burden was achieved at 0.6 µg/mL triclosan. One exception was S. aureus strain H-5-24, where a triclosan concentration of 0.6 µg/mL required 1 minute without and 10 minutes with albumin burden to achieve the same logRFs. Polihexanide achieved a logRF >5 without and logRF >3 with albumin burden at a concentration of 0.6 µg/mL within 30 sec. The exception was the North-German epidemic MRSA strain, were an application time of 5 minutes was required. Conclusion: The clinical isolates of E. coli generally showed higher MICs against triclosan, both in the micro-dilution assay as well in the quantitative suspension test than comparable reference laboratory strains. For polihexanide and triclosan strain dependant susceptibility was shown. However, both antimicrobial compounds are effective when used in concentrations common in practice. PMID:22242087
2002-01-01
A total of 522 strains belonging to streptococci, enterococci and staphylococci isolated from sub-clinical and clinical cases of bovine mastitis from the west littoral region of Uruguay were analysed for their susceptibility to several antimicrobial agents. The susceptibility patterns were studied by agar disk diffusion methods (ADDM) and broth micro-dilution to determine the minimum inhibitory concentration (MIC). The concentration that inhibits 90% (MIC90) of the analysed strains reported in micrograms per millilitre, for Staphylococcus aureus were > 8, 8, ≤ 0.5, ≤ 4, ≤ 1, ≤ 0.5, > 64, ≤ 0.25, 0.5, ≤ 1 and ≤ 1 to penicillin, ampicillin, oxacillin, cephalotin, gentamicin, erythromycin, oxitetracycline, enrofloxacin, trimethoprim/sulfamethoxazole, neomycin, and clindamycin, respectively. Coagulase-negative staphylococci (CNS) had different values for penicillin (4) and ampicillin (2), while the other antimicrobial agents had the same MIC90 values as reported for S. aureus. The MIC90 values for streptococci were 0.12, 0.25, ≤ 4, 16, ≤ 0.25, 0.5, 0.25 for penicillin, ampicillin, cephalotin, gentamicin, erythromycin, oxytetracycline and trimethoprim-sulfamethoxazole, whereas MIC90 for enterococci were 4, 4, 4, ≤ 0.5, 2, > 8 for penicillin, ampicillin, gentamicin, erythromycin, oxytetracycline and trimethoprim-sulfamethoxazole, respectively. Of 336 strains of S. aureus, 160 (47.6%) were resistant to penicillin. For 41 CNS strains, 10 (27%) presented penicillin-resistance. All the streptococcal strains were susceptible to penicillin, while 3 (7%) of the 43 enteroccocal strains were resistant. Non significant statistical differences were found between the results obtained by ADDM and broth micro-dilution for classifying bacterial isolates as susceptible or resistant according to the National Committee of Clinical Laboratory Standards. PMID:12071114
Effect of γ-lactones and γ-lactams compounds on Streptococcus mutans biofilms
Sordi, Mariane Beatriz; Moreira, Thaís Altoé; Montero, Juan Felipe Dumes; Barbosa, Luis Cláudio; Benfatti, César Augusto Magalhães; Magini, Ricardo de Souza; Pimenta, Andréa de Lima
2018-01-01
Abstract Considering oral diseases, antibiofilm compounds can decrease the accumulation of pathogenic species such as Streptococcus mutans at micro-areas of teeth, dental restorations or implant-supported prostheses. Objective To assess the effect of thirteen different novel lactam-based compounds on the inhibition of S. mutans biofilm formation. Material and methods We synthesized compounds based on γ-lactones analogues from rubrolides by a mucochloric acid process and converted them into their corresponding γ-hydroxy-γ-lactams by a reaction with isobutylamine and propylamine. Compounds concentrations ranging from 0.17 up to 87.5 μg mL-1 were tested against S. mutans. We diluted the exponential cultures in TSB and incubated them (37°C) in the presence of different γ-lactones or γ-lactams dilutions. Afterwards, we measured the planktonic growth by optical density at 630 nm and therefore assessed the biofilm density by the crystal violet staining method. Results Twelve compounds were active against biofilm formation, showing no effect on bacterial viability. Only one compound was inactive against both planktonic and biofilm growth. The highest biofilm inhibition (inhibition rate above 60%) was obtained for two compounds while three other compounds revealed an inhibition rate above 40%. Conclusions Twelve of the thirteen compounds revealed effective inhibition of S. mutans biofilm formation, with eight of them showing a specific antibiofilm effect. PMID:29489934
Enhancement of bismuth antibacterial activity with lipophilic thiol chelators.
Domenico, P; Salo, R J; Novick, S G; Schoch, P E; Van Horn, K; Cunha, B A
1997-01-01
The antibacterial properties of bismuth are greatly enhanced when bismuth is combined with certain lipophilic thiol compounds. Antibacterial activity was enhanced from 25- to 300-fold by the following seven different thiols, in order of decreasing synergy: 1,3-propanedithiol, dimercaprol (BAL), dithiothreitol, 3-mercapto-2-butanol, beta-mercaptoethanol, 1-monothioglycerol, and mercaptoethylamine. The dithiols produced the greatest synergy with bismuth at optimum bismuth-thiol molar ratios of from 3:1 to 1:1. The monothiols were generally not as synergistic and required molar ratios of from 1:1 to 1:4 for optimum antibacterial activity. The most-active mono- or dithiols were also the most soluble in butanol. The intensity of the yellow formed by bismuth-thiol complexes reflected the degree of chelation and correlated with antibacterial potency at high molar ratios. The bismuth-BAL compound (BisBAL) was active against most bacteria, as assessed by broth dilution, agar diffusion, and agar dilution analyses. Staphylococci (MIC, 5 to 7 microM Bi3+) and Helicobacter pylori (MIC, 2.2 microM) were among the most sensitive bacteria. Gram-negative bacteria were sensitive (MIC, < 17 microM). Enterococci were relatively resistant (MIC, 63 microM Bi3+). The MIC range for anaerobes was 15 to 100 microM Bi3+, except for Clostridium difficile (MIC, 7.5 microM). Bactericidal activity averaged 29% above the MIC. Bactericidal activity increased with increasing pH and/or increasing temperature. Bismuth-thiol solubility, stability, and antibacterial activity depended on pH and the bismuth-thiol molar ratio. BisBAL was stable but ineffective against Escherichia coli at pH 4. Activity and instability (reactivity) increased with increasing alkalinity. BisBAL was acid soluble at a molar ratio of greater than 3:2 and alkaline soluble at a molar ratio of less than 2:3. In conclusion, certain lipophilic thiol compounds enhanced bismuth antibacterial activity against a broad spectrum of bacteria. The activity, solubility, and stability of BisBAL were strongly dependent on the pH, temperature, and molar ratio. Chelation of bismuth with certain thiol agents enhanced the solubility and lipophilicity of this cationic heavy metal, thereby significantly enhancing its potency and versatility as an antibacterial agent. PMID:9257744
Disentangling niche competition from grazing mortality in phytoplankton dilution experiments
Weitz, Joshua S.
2017-01-01
The dilution method is the principal tool used to infer in situ microzooplankton grazing rates. However, grazing is the only mortality process considered in the theoretical model underlying the interpretation of dilution method experiments. Here we evaluate the robustness of mortality estimates inferred from dilution experiments when there is concurrent niche competition amongst phytoplankton. Using a combination of mathematical analysis and numerical simulations, we find that grazing rates may be overestimated—the degree of overestimation is related to the importance of niche competition relative to microzooplankton grazing. In response, we propose a conceptual method to disentangle the effects of niche competition and grazing by diluting out microzooplankton, but not phytoplankton. Our theoretical results suggest this revised “Z-dilution” method can robustly infer grazing mortality, regardless of the dominant phytoplankton mortality driver in our system. Further, we show it is possible to independently estimate both grazing mortality and niche competition if the classical and Z-dilution methods can be used in tandem. We discuss the significance of these results for quantifying phytoplankton mortality rates; and the feasibility of implementing the Z-dilution method in practice, whether in model systems or in complex communities with overlap in the size distributions of phytoplankton and microzooplankton. PMID:28505212
NASA Astrophysics Data System (ADS)
Görmez, Arzu; Yanmiş, Derya; Bozari, Sedat; Gürkök, Sumeyra
2017-04-01
The antibiotic resistance of pathogenic microorganisms has become a worldwide concern to public health. To overcome the current resistance problem, new antimicrobial agents are extremely needed. The aim of the present study was to evaluate the antibacterial activity of Satureja hortensis essential oils against seven clinical pathogens. Chemical compositions of hydro distillated essential oils from S. hortensis were analyzed by GS-MS. The antibacterial activity was investigated against Corynebacterium diphtheria, Salmonella typhimurium, Serratia plymuthica Yersinia enterocolitica, Y. frederiksenii, Y. pseudotuberculosis and Vibrio cholerae by the use of disc diffusion method and broth micro dilution method. The minimum inhibitory concentration (MIC) values of essential oils were found as low as 7.81 µg/mL. Notably, essential oils of S. hortensis exhibited remarkable antimicrobial activities against the tested clinical pathogens. The results indicate that these essential oils can be used in treatment of different infectious diseases.
NASA Astrophysics Data System (ADS)
Ghasemian, Motaleb; Kakanejadifard, Ali; Karami, Tahereh
2016-11-01
The azo-azomethine dyes with a different substitution have been designed from the reaction of 4,4‧-diaminodiphenyl sulfone with 2-hydroxy-5-(aryldiazenyl)benzaldehyde. The compounds have been characterized by elemental analysis, Mass, IR, UV-Vis, TGA-DTA and NMR spectroscopy. The solvatochromism behaviors, effects of substitution and pH on the electronic absorption spectra of dyes were evaluated. The in vitro antimicrobial activities were also screened for their potential for antibiotic activities by broth micro dilution method. Also, the optimum molecular geometries, molecular electrostatic potential (MEP), nucleus-independent chemical shift (NICS) and frontier molecular orbitals (FMO), vibrational spectra (IR) and electronic absorption (UV-Vis) spectra of the title compounds have been investigated with the help of DFT and TDDFT methods with 6-311 ++G(d,p) basis sets and PCM calculations. The results of the calculations show excellent agreement with the experimental value.
Antimicrobial activity of bark extracts of Syzygium jambos (L.) alston (Myrtaceae).
Djipa, C D; Delmée, M; Quetin-Leclercq, J
2000-07-01
Syzygium jambos (L.) Alston (Myrtaceae) is a widespread medicinal plant traditionally used in sub-Saharan Africa to treat infectious diseases. Acetone and aqueous extracts from the bark of S. jambos were tested for antimicrobial activity in vitro by the agar dilution method in petri dishes. Both extracts showed some activity against the tested micro-organisms. They proved to be particularly effective on Staphylococcus aureus, Yersinia enterocolitica and coagulase negative staphylococci among which Staphylococcus hominis, Staphylococcus cohnii and Staphylococcus warneri. These properties seem to be related to the high tannin content of S. jambos extracts (77 and 83% for the aqueous and acetone extracts, respectively, determined according to the European Pharmacopoeia method) which were generally more active than Hamamelis virginiana, Krameria triandra, Alchemilla vulgaris and Rubus fruticosus extracts containing 48, 44, 46 and 28% tannins, respectively. Furthermore, elimination of tannins totally suppressed these antimicrobial activities.
Bharath, Nagaraj; Sowmya, Nagur Karibasappa; Mehta, Dhoom Singh
2015-01-01
The aim of this study was to evaluate the antibacterial activity of pure green coffee bean extract on periodonto pathogenic bacteria Porphyromonas gingivalis (Pg), Prevotella intermedia (Pi), Fusobacterium nucleatum (Fn) and Aggregatibacter actinomycetemcomitans (Aa). Minimum inhibitory concentrations (MICs) and minimum bactericidal concentrations (MBC) were used to assess the antibacterial effect of pure green coffee bean extract against periodonto pathogenic bacteria by micro dilution method and culture method, respectively. MIC values of Pg, Pi and Aa were 0.2 μg/ml whereas Fn showed sensitive at concentration of 3.125 μg/ml. MBC values mirrors the values same as that of MIC. Antimicrobial activity of pure green coffee bean extract against Pg, Pi, Fn and Aa suggests that it could be recommended as an adjunct to mechanical therapy in the management of periodontal disease.
Hu, Junpeng; Jia, Mengmeng; Zhu, Liang
2018-04-18
The essential oil obtained from Wedelia urticifolia growing in Hunan Province, China, was analyzed for the first time by capillary GC and GC-MS. A total of 67 constituents, representing 98.68% in essential oil were identified. The major constituents of the oil were: α-pinene (8.85%), limonene (6.38%), carvacrol (6.15%), caryophyllene (6.08%), spathulenol (5.49%), sabinene (5.36%), camphor (4.34%). Antimicrobial potential of oil against bacterial strains (Pseudomonas aeruginosa, Escherichia coli and Bacillus subtilis, and Staphylococcus aureus), yeast strains (Hansenula anomala and Saccharomy cescerevisiae) and molds (Aspergillus niger, Chaetomium globosum, Mucor racemosus, and Monascus anka) was determined by disc diffusion method and broth micro dilution method, respectively. The oil exhibited promising antimicrobial effect as a diameter of zones of inhibition (16.8-24.9 mm). Minimum inhibitory concentration values of oil were ranged 62.5-1000 μg/mL.
NASA Astrophysics Data System (ADS)
Rajagopalan, T.; Wang, X.; Lahlouh, B.; Ramkumar, C.; Dutta, Partha; Gangopadhyay, S.
2003-10-01
Nanocrystalline silicon carbide (SiC) thin films were deposited by plasma enhanced chemical vapor deposition technique at different deposition temperatures (Td) ranging from 80 to 575 °C and different gas flow ratios (GFRs). While diethylsilane was used as the source for the preparation of SiC films, hydrogen, argon and helium were used as dilution gases in different concentrations. The effects of Td, GFR and dilution gases on the structural and optical properties of these films were investigated using high resolution transmission electron microscope (HRTEM), micro-Raman, Fourier transform infrared (FTIR) and ultraviolet-visible optical absorption techniques. Detailed analysis of the FTIR spectra indicates the onset of formation of SiC nanocrystals embedded in the amorphous matrix of the films deposited at a temperature of 300 °C. The degree of crystallization increases with increasing Td and the crystalline fraction (fc) is 65%±2.2% at 575 °C. The fc is the highest for the films deposited with hydrogen dilution in comparison with the films deposited with argon and helium at the same Td. The Raman spectra also confirm the occurrence of crystallization in these films. The HRTEM measurements confirm the existence of nanocrystallites in the amorphous matrix with a wide variation in the crystallite size from 2 to 10 nm. These results are in reasonable agreement with the FTIR and the micro-Raman analysis. The variation of refractive index (n) with Td is found to be quite consistent with the structural evolution of these films. The films deposited with high dilution of H2 have large band gap (Eg) and these values vary from 2.6 to 4.47 eV as Td is increased from 80 to 575 °C. The size dependent shift in the Eg value has also been investigated using effective mass approximation. Thus, the observed large band gap is attributed to the presence of nanocrystallites in the films.
Tomasino, Stephen F; Fiumara, Rebecca M; Cottrill, Michele P
2006-01-01
The AOAC Use-Dilution methods do not provide procedures to enumerate the test microbe on stainless steel carriers (penicylinders) or guidance on the expected target populations of the test microbe (i.e., a performance standard). This report describes the procedures used by the U.S. Environmental Protection Agency to enumerate the test microbe (carrier counts) associated with conducting the Use-Dilution method with Staphylococcus aureus (Method 955.15) and Pseudomonas aeruginosa (Method 964.02) and the examination of historical data. The carrier count procedure involves the random selection of carriers, shearing bacterial cells from the carrier surface through sonication, and plating of serially diluted inoculum on trypticase soy agar. For each Use-Dilution test conducted, the official AOAC method was strictly followed for carrier preparation, culture initiation, test culture preparation, and carrier inoculation steps. Carrier count data from 78 Use-Dilution tests conducted over a 6-year period were compiled and analyzed. A mean carrier count of 6.6 logs (approximately 4.0 x 10(6) colony-forming units/carrier) was calculated for both S. aureus and P. aeruginosa. Of the mean values, 95% fell within +/- 2 repeatability standard deviations. The enumeration procedure and target carrier counts are desirable for standardizing the Use-Dilution methods, increasing their reproducibility, and ensuring the quality of the data.
Sensitive Spin Detection Using An On-Chip Squid-Waveguide Resonator
NASA Astrophysics Data System (ADS)
Yue, Guang
Quantum computing gives novel way of computing using quantum mechanics, which furthers human knowledge and has exciting applications. Quantum systems with diluted spins such as rare earth ions hosted in single crystal, molecule-based magnets etc. are promising qubits candidates to form the basis of a quantum computer. High sensitivity measurement and coherent control of these spin systems are crucial for their practical usage as qubits. The micro-SQUID (direct-current micrometer-sized Superconducting QUantum Interference Device) is capable to measure magnetization of spin system with high sensitivity. For example, the micro-SQUID technique can measure magnetic moments as small as several thousand muB as shown by the study of [W. Wernsdorfer, Supercond. Sci. Technol. 22, 064013 (2009)]. Here we develop a novel on-chip setup that combines the micro-SQUID sensitivity with microwave excitation. Such setup can be used for electron spin resonance measurements or coherent control of spins utilizing the high sensitivity of micro-SQUID for signal detection. To build the setup, we studied the fabrication process of the micro-SQUID, which is made of weak-linked Josephson junctions. The SQUID as a detector is integrated on the same chip with a shorted coplanar waveguide, so that the microwave pulses can be applied through the waveguide to excite the sample for resonance measurements. The whole device is plasma etched from a thin (˜ 20nm) niobium film, so that the SQUID can work at in large in-plane magnetic fields of several tesla. In addition, computer simulations are done to find the best design of the waveguide such that the microwave excitation field is sufficiently strong and uniformly applied to the sample. The magnetization curve of Mn12 molecule-based magnet sample is measured to prove the proper working of the micro-SQUID. Electron spin resonance measurement is done on the setup for gadolinium ions diluted in a CaWO4 single crystal. The measurement shows clear evidence of the resonance signal from the 1st transition of the gadolinium ions' energy levels, which shows the setup is successfully built. Due to the high sensitivity of micro-SQUID and the ability to concentrate microwave energy in small areas of the chip, this setup can detect signals from a small number of spins (107) in a small volume (several mum 3).
A new gas dilution method for measuring body volume.
Nagao, N; Tamaki, K; Kuchiki, T; Nagao, M
1995-01-01
This study was designed to examine the validity of a new gas dilution method (GD) for measuring human body volume and to compare its accuracy with the results obtained by the underwater weighing method (UW). We measured the volume of plastic bottles and 16 subjects (including two females), aged 18-42 years with each method. For the bottles, the volume measured by hydrostatic weighing was correlated highly (r = 1.000) with that measured by the new gas dilution method. For the subjects, the body volume determined by the two methods was significantly correlated (r = 0.998). However, the subject's volume measured by the gas dilution method was significantly larger than that by underwater weighing method. There was significant correlation (r = 0.806) between GD volume-UW volume and the body mass index (BMI), so that UW volume could be predicted from GD volume and BMI. It can be concluded that the new gas dilution method offers promising possibilities for future research in the population who cannot submerge underwater. PMID:7551760
Gentile, Francesco; Coluccio, Maria Laura; Zaccaria, Remo Proietti; Francardi, Marco; Cojoc, Gheorghe; Perozziello, Gerardo; Raimondo, Raffaella; Candeloro, Patrizio; Di Fabrizio, Enzo
2014-07-21
Super-hydrophobic surfaces are bio-inspired interfaces with a superficial texture that, in its most common evolution, is formed by a periodic lattice of silicon micro-pillars. Similar surfaces reveal superior properties compared to conventional flat surfaces, including very low friction coefficients. In this work, we modified meso-porous silicon micro-pillars to incorporate networks of metal nano-particles into the porous matrix. In doing so, we obtained a multifunctional-hierarchical system in which (i) at a larger micrometric scale, the super-hydrophobic pillars bring the molecules dissolved in an ultralow-concentration droplet to the active sites of the device, (ii) at an intermediate meso-scale, the meso-porous silicon film adsorbs the low molecular weight content of the solution and, (iii) at a smaller nanometric scale, the aggregates of silver nano-particles would measure the target molecules with unprecedented sensitivity. In the results, we demonstrated how this scheme can be utilized to isolate and detect small molecules in a diluted solution in very low abundance ranges. The presented platform, coupled to Raman or other spectroscopy techniques, is a realistic candidate for the protein expression profiling of biological fluids.
Sadgrove, Nicholas John; Hitchcock, Maria; Watson, Kenneth; Jones, Graham Lloyd
2013-10-01
Essential oils were extracted by hydrodistillation from the traditional Australian medicinal plant Eremophila bignoniiflora, characterized chemically and then screened for bioactivity. Characterization and quantification were completed using gas chromatography-mass spectrometry (GC-MS) and GC-flame ionization detection, respectively. Antimicrobial capacity was assessed using disc diffusion and micro-titre plate broth dilution and further characterized using thin layer chromatography followed by bioautography to assign activity to separated individual active components. Antifungal capacity was investigated using micro-titre plate broth dilution against pathogenic Trichophyton species. Free radical scavenging ability was assessed using the diphenylpicrylhydradyl reaction in methanol. The predominant components of the essential oil were fenchyl-acetate and bornyl-acetate. However, bioautography indicated antimicrobial ability to be largely linked to the less abundant, more polar constituents. Oils displayed only modest antifungal ability against pathogenic Trichophyton species associated with dermatophytosis, but moderate to high antimicrobial activity, particularly against the yeast Candida albicans and the bacteria Staphylococcus epidermidis. Essential oils exhibited relatively low free radical scavenging ability. Speculation over the role of essential oils in the traditional medicinal applications of E. bignoniiflora follows, exploring correlations between traditional use and investigated bioactivities. Copyright © 2012 John Wiley & Sons, Ltd.
Antibacterial, antifungal and cytotoxic evaluation of some new quinazolinone derivatives
Hassanzadeh, F.; Jafari, E.; Hakimelahi, G.H.; Khajouei, M. Rahmani; Jalali, M.; Khodarahmi, G.A.
2012-01-01
Quinazolinone ring system is renown because of its wide spectrum of pharmacological activities due to various substitutions on this ring system. In this study, the minimum inhibitory concentration of the synthesized compounds in our laboratory was determined by micro dilution Alamar Blue® Assay against six strains of bacteria (three Gram-positive and three Gram-negative) and three strains of fungi. Following a broth micro dilution minimum inhibitory concentration (MIC) test, Minimum Bactericidal Concentration (MBC) and Minimum Fungicidal Concentration (MFC) tests were performed. Cytotoxic effects of the compounds were measured using the MTT colorimetric assay on HeLa cell line. Results of antimicrobial screening showed that compounds had better bacteriostatic activity against Gram-negative bacteria. Results from MBC revealed that these compounds had more significant bacteriostatic than bactericidal activities. Nearly all screened compounds showed good activity against C. albicans and A. niger. Results from MFC indicated that these compounds had better fungistatic rather than fungicidal activities. The synthesized target molecules were found to exhibit different cytotoxicity in the range of 10 to 100 μM on HeLa cell line. Compounds 6 and 7 exhibited acceptable cytotoxicity approximately 50% at 10 μM concentration. PMID:23181085
Bharath, Nagaraj; Sowmya, Nagur Karibasappa; Mehta, Dhoom Singh
2015-01-01
Background: The aim of this study was to evaluate the antibacterial activity of pure green coffee bean extract on periodonto pathogenic bacteria Porphyromonas gingivalis (Pg), Prevotella intermedia (Pi), Fusobacterium nucleatum (Fn) and Aggregatibacter actinomycetemcomitans (Aa). Materials and Methods: Minimum inhibitory concentrations (MICs) and minimum bactericidal concentrations (MBC) were used to assess the antibacterial effect of pure green coffee bean extract against periodonto pathogenic bacteria by micro dilution method and culture method, respectively. Results: MIC values of Pg, Pi and Aa were 0.2 μg/ml whereas Fn showed sensitive at concentration of 3.125 μg/ml. MBC values mirrors the values same as that of MIC. Conclusion: Antimicrobial activity of pure green coffee bean extract against Pg, Pi, Fn and Aa suggests that it could be recommended as an adjunct to mechanical therapy in the management of periodontal disease. PMID:26097349
Petti, S; Renzini, G
1994-03-01
The percentage of anaerobic micro-organisms in the subgingival microflora represents a simple microbiological index which not only refers to the state but also the risks of periodontal health. The present study aimed to compare two different methods of calculating this index. The study was performed in 45 subjects with moderate gingivitis provoked by the previous application of dental fixtures anchored to both arches. A sample of subgingival microflora was collected from each patient at the level of the vestibular gingival sulcus of the first upper right molar. This was then vortexed, diluted and inoculated in three series of plates. It was chosen to use Walker's culture medium. The total bacterial count was evaluated by incubating the first series of plates in anaerobiosis; the anaerobic bacterial was calculated by subtracting from the total the of facultative aerobic-anaerobic micro-organisms, which in turn was obtained using two methods: the first (method AE) consisted of incubating another series of plates in aerobiosis; the second (method M) involved incubating the last series of plates in anaerobiosis, and adding metronidazole to the culture medium in a solution of 2.5 mg/l. The plates were then kept at 37 degrees C for seven days. The mean percentage of anaerobic microorganisms, given by the percentage ratio between anaerobic and total, relating to the 45 cases studied, was as follows: using method AE: 57.8 +/- 26.3%, and using method M: 40.2 +/- 27.2%. Both figures come close to that proposed and calculated using a much more sophisticated method by Slots, namely 41.5 +/- 19.2% in the event of gingivitis.(ABSTRACT TRUNCATED AT 250 WORDS)
Vieira, José Gilberto H; Nakamura, Odete H; Carvalho, Valdemir M
2005-04-01
Free urinary cortisol (UFF) measurement is one of the most useful screening tests for Cushing's syndrome. Immunoassays employed today by most clinical laboratories present limitations, specially concerning specificity. These limitations restrain a widespread application of the method, as well as the comparison of results obtained by the use of different methods. We present the development and characterization of a UFF and cortisone method based on liquid chromatography and tandem mass spectrometry (LC-MS/MS). A 200 microL aliquot from a 24 h urine sample is mixed with a solution containing a known quantity of deuterated cortisol and on-line extracted in solid phase (C18). The eluate is transferred to a second C18 column (Phenomenex Luna, 3 micro, 50 x 2 mm) and the isocratic mode elution profile is directly applied to a tandem mass spectrometer model Quattro Micro operating in positive mode atmospheric pressure chemical ionization (APCI). All process is automated and the quantification is performed by isotopic dilution, based on the analyte and the deuterated internal standard peak area ratios. The specificity study showed that all the steroids tested presented cross reactivity of <1% for cortisol and cortisone. Functional sensitivity is <1 microg/L for both steroids, and the interassay CV <8%. Recovery and linearity studies were satisfactory and comparison of results obtained using a RIA for UFF and the present method in 98 routine samples showed a correlation of r= 0.838, with the results obtained with LC-MS/MS significantly lower (medians of 22.0 vs. 49.4 microg/24 h for RIA) (P<0.0001). Reference values for cortisol were defined as values between 11 and 43 microg/24 h, compatible to those recently described for similar methods. The concomitant measurement of UF cortisone allows the study of the activity of the enzyme 11beta-HSD2 and the diagnosis of the apparent mineralocorticoid excess syndrome. The method represents the first steroid assay of a new generation, based on automated preparative methods and tandem mass spectrometry, described in our country.
Farthing, William Earl [Pinson, AL; Felix, Larry Gordon [Pelham, AL; Snyder, Todd Robert [Birmingham, AL
2008-02-12
An apparatus and method for diluting and cooling that is extracted from high temperature and/or high pressure industrial processes. Through a feedback process, a specialized, CFD-modeled dilution cooler is employed along with real-time estimations of the point at which condensation will occur within the dilution cooler to define a level of dilution and diluted gas temperature that results in a gas that can be conveyed to standard gas analyzers that contains no condensed hydrocarbon compounds or condensed moisture.
Farthing, William Earl; Felix, Larry Gordon; Snyder, Todd Robert
2009-12-15
An apparatus and method for diluting and cooling that is extracted from high temperature and/or high pressure industrial processes. Through a feedback process, a specialized, CFD-modeled dilution cooler is employed along with real-time estimations of the point at which condensation will occur within the dilution cooler to define a level of dilution and diluted gas temperature that results in a gas that can be conveyed to standard gas analyzers that contains no condensed hydrocarbon compounds or condensed moisture.
Mahboubi, M; Kazempour, N
2011-01-01
Background and Objectives The aim of this study was to evaluate the chemical composition and antimicrobial activity of Satureja hortensis and Trachyspermum copticum essential oils against different kinds of microorganisms in vitro. Material and Methods The antimicrobial activity was evaluated by micro broth dilution assay and the chemical composition of essential oils was analyzed by GC and GC/MS. Results Thymol, p-cymene, γ-terpinene and carvacrol were the main components of S. hortensis oil while thymol, γ-terpinene, and o-cymene were the major components of T. copticum oil. Two essential oils exhibited strong antimicrobial activity but the antimicrobial activity of T. copticum oil was higher than that of S. hortensis oil. Conclusion Thymol as a main component of oils plays an important role in antimicrobial activity. PMID:22530088
Golfakhrabadi, Fereshteh; Shams Ardekani, Mohammad Reza; Saeidnia, Soodabeh; Yousefbeyk, Fatemeh; Jamalifar, Hossein; Ramezani, Nasrin; Akbarzadeh, Tahmineh; Khanavi, Mahnaz
2016-03-01
Ferulago carduchorum (Apiaceae family) is an endemic plant of Iran. The crude extract and four fractions of aerial parts of F. carduchorum in two vegetative stages (flower and fruit) were studied for their total phenolic contents, antimicrobial and antioxidant activities using folin-ciocalteu assay, micro dilution method and DPPH assay, respectively. The results indicated that the best antioxidant activity was determined in flower crude extract (IC50=0.44 mg/mL). The flower ethyl acetate fraction (FLE) showed better antimicrobial and antifungal activities than other fractions. So, FLE was selected for phytochemical investigations, resulting in isolation of a flavonoid (hesperetin). Hesperetin showed antimicrobial activity. The results showed that the antimicrobial and antioxidant effects during the flowering are obviously more than the fruit season.
Salamon, S; Ritar, A J
1982-01-01
Five factorial experiments were conducted to examine the effects of concentration of tris(hydroxymethyl)aminomethane (Tris), type and concentration of sugar in the diluent, rate and method of dilution on the survival of goat spermatozoa after freezing by the pellet method. Spermatozoa tolerated a relatively wide range in concentration of Tris, but the cell survival depended on the type of sugar included in the Tris diluent. Glucose and fructose were more suitable components than lactose or raffinose. Survival of spermatozoa after thawing was better for three- to fivefold prefreezing dilution. There was interaction between method of semen dilution (one-step, two-step), holding time at 5 degrees C, and glycerol concentration. The best result was obtained after one-step dilution at 30 degrees C (Tris 375 mM-glucose 41.625 mM-citric acid 124 mM), 1.5 h holding at 5 degrees C, and with 4% (v/v) glycerol concentration in the diluted semen.
Determination of phosphorus in small amounts of protein samples by ICP-MS.
Becker, J Sabine; Boulyga, Sergei F; Pickhardt, Carola; Becker, J; Buddrus, Stefan; Przybylski, Michael
2003-02-01
Inductively coupled plasma mass spectrometry (ICP-MS) is used for phosphorus determination in protein samples. A small amount of solid protein sample (down to 1 micro g) or digest (1-10 micro L) protein solution was denatured in nitric acid and hydrogen peroxide by closed-microvessel microwave digestion. Phosphorus determination was performed with an optimized analytical method using a double-focusing sector field inductively coupled plasma mass spectrometer (ICP-SFMS) and quadrupole-based ICP-MS (ICP-QMS). For quality control of phosphorus determination a certified reference material (CRM), single cell proteins (BCR 273) with a high phosphorus content of 26.8+/-0.4 mg g(-1), was analyzed. For studies on phosphorus determination in proteins while reducing the sample amount as low as possible the homogeneity of CRM BCR 273 was investigated. Relative standard deviation and measurement accuracy in ICP-QMS was within 2%, 3.5%, 11% and 12% when using CRM BCR 273 sample weights of 40 mg, 5 mg, 1 mg and 0.3 mg, respectively. The lowest possible sample weight for an accurate phosphorus analysis in protein samples by ICP-MS is discussed. The analytical method developed was applied for the analysis of homogeneous protein samples in very low amounts [1-100 micro g of solid protein sample, e.g. beta-casein or down to 1 micro L of protein or digest in solution (e.g., tau protein)]. A further reduction of the diluted protein solution volume was achieved by the application of flow injection in ICP-SFMS, which is discussed with reference to real protein digests after protein separation using 2D gel electrophoresis.The detection limits for phosphorus in biological samples were determined by ICP-SFMS down to the ng g(-1) level. The present work discusses the figure of merit for the determination of phosphorus in a small amount of protein sample with ICP-SFMS in comparison to ICP-QMS.
Estimation method for serial dilution experiments.
Ben-David, Avishai; Davidson, Charles E
2014-12-01
Titration of microorganisms in infectious or environmental samples is a corner stone of quantitative microbiology. A simple method is presented to estimate the microbial counts obtained with the serial dilution technique for microorganisms that can grow on bacteriological media and develop into a colony. The number (concentration) of viable microbial organisms is estimated from a single dilution plate (assay) without a need for replicate plates. Our method selects the best agar plate with which to estimate the microbial counts, and takes into account the colony size and plate area that both contribute to the likelihood of miscounting the number of colonies on a plate. The estimate of the optimal count given by our method can be used to narrow the search for the best (optimal) dilution plate and saves time. The required inputs are the plate size, the microbial colony size, and the serial dilution factors. The proposed approach shows relative accuracy well within ±0.1log10 from data produced by computer simulations. The method maintains this accuracy even in the presence of dilution errors of up to 10% (for both the aliquot and diluent volumes), microbial counts between 10(4) and 10(12) colony-forming units, dilution ratios from 2 to 100, and plate size to colony size ratios between 6.25 to 200. Published by Elsevier B.V.
Chen, Fangfang; Gong, Zhiyuan; Kelly, Barry C
2015-02-27
A sensitive analytical method based on liquid-liquid extraction (LLE) and liquid chromatography tandem mass spectrometry (LC-MS/MS) was developed for rapid analysis of 11 pharmaceuticals and personal care products (PPCPs) in fish plasma micro-aliquots (∼20μL). Target PPCPs included, bisphenol A, carbamazepine, diclofenac, fluoxetine, gemfibrozil, ibuprofen, naproxen, risperidone, sertraline, simvastatin and triclosan. A relatively quicker and cheaper LLE procedure exhibited comparable analyte recoveries with solid-phase extraction. Rapid separation and analysis of target compounds in fish plasma extracts was achieved by employing a high efficiency C-18 HPLC column (Agilent Poroshell 120 SB-C18, 2.1mm×50mm, 2.7μm) and fast polarity switching, enabling effective monitoring of positive and negative ions in a single 9min run. With the exception of bisphenol A, which exhibited relatively high background contamination, method detection limits of individual PPCPs ranged between 0.15 and 0.69pg/μL, while method quantification limits were between 0.05 and 2.3pg/μL. Mean matrix effect (ME) values ranged between 65 and 156% for the various target analytes. Isotope dilution quantification using isotopically labelled internal surrogates was utilized to correct for signal suppression or enhancement and analyte losses during sample preparation. The method was evaluated by analysis of 20μL plasma micro-aliquots collected from zebrafish (Danio rerio) from a laboratory bioaccumulation study, which included control group fish (no exposure), as well as fish exposed to environmentally relevant concentrations of PPCPs. Using the developed LC-MS/MS based method, concentrations of the studied PPCPs were consistently detected in the low pg/μL (ppb) range. The method may be useful for investigations requiring fast, reliable concentration measurements of PPCPs in fish plasma. In particular, the method may be applicable for in situ contaminant biomonitoring, as well as bioaccumulation and toxicology studies employing small fishes with low blood compartment volumes. Copyright © 2015 Elsevier B.V. All rights reserved.
Videodensitometric Methods for Cardiac Output Measurements
NASA Astrophysics Data System (ADS)
Mischi, Massimo; Kalker, Ton; Korsten, Erik
2003-12-01
Cardiac output is often measured by indicator dilution techniques, usually based on dye or cold saline injections. Developments of more stable ultrasound contrast agents (UCA) are leading to new noninvasive indicator dilution methods. However, several problems concerning the interpretation of dilution curves as detected by ultrasound transducers have arisen. This paper presents a method for blood flow measurements based on UCA dilution. Dilution curves are determined by real-time densitometric analysis of the video output of an ultrasound scanner and are automatically fitted by the Local Density Random Walk model. A new fitting algorithm based on multiple linear regression is developed. Calibration, that is, the relation between videodensity and UCA concentration, is modelled by in vitro experimentation. The flow measurement system is validated by in vitro perfusion of SonoVue contrast agent. The results show an accurate dilution curve fit and flow estimation with determination coefficient larger than 0.95 and 0.99, respectively.
Actuated rheology of magnetic micro-swimmers suspensions: Emergence of motor and brake states
NASA Astrophysics Data System (ADS)
Vincenti, Benoit; Douarche, Carine; Clement, Eric
2018-03-01
We study the effect of magnetic field on the rheology of magnetic micro-swimmers suspensions. We use a model of a dilute suspension under simple shear and subjected to a constant magnetic field. Particle shear stress is obtained for both pusher and puller types of micro-swimmers. In the limit of low shear rate, the rheology exhibits a constant shear stress, called actuated stress, which only depends on the swimming activity of the particles. This stress is induced by the magnetic field and can be positive (brake state) or negative (motor state). In the limit of low magnetic fields, a scaling relation of the motor-brake effect is derived as a function of the dimensionless parameters of the model. In this case, the shear stress is an affine function of the shear rate. The possibilities offered by such an active system to control the rheological response of a fluid are finally discussed.
Biconcave micro-optofluidic lens with low-refractive-index liquids.
Song, Chaolong; Nguyen, Nam-Trung; Asundi, Anand Krishna; Low, Cassandra Lee-Ngo
2009-12-01
One of the current problems of micro-optofluidics is the choice of a suitable liquid with a high refractive index (RI). We report the use of a low-RI liquid in a biconcave liquid-core liquid-cladding lens for focusing light. For the characterization of the lens, a telescope system was constructed from polydimethylsiloxane lenses to collimate and expand a light beam emitted from an optical fiber. The tunable optofluidic biconcave lens focuses the parallel beam. Fluorescent dye diluted in an index-matching liquid was used for the visualization of the light rays in a beam-tracing chamber. The focused beam is tuned by adjusting the flow rate ratio between core and cladding streams.
Campbell, W M; Dombroski, G S; Sharma, I; Partridge, A C; Collett, M G
2010-06-01
To validate a spectrofluorometric method for measuring chlorophyll a metabolites, specifically phytoporphyrin (= phylloerythrin), as well as the chlorins, pheophorbide a and pyropheophorbide a, in the blood of photosensitive cattle and sheep. Standard methanolic solutions of pheophorbide a (25 microM), pyropheophorbide a (25 microM), and phytoporphyrin (<3.7 microM) were prepared. Serum and plasma samples were obtained from cattle (n=5), sheep (n=3), and one alpaca, with clinical facial eczema (i.e. photosensitive), as well as from clinically normal (n=2 of each) adult cows, recently weaned calves, and sheep (controls). Standard solutions of the three metabolites were characterised using high-performance liquid chromatography (HPLC), with mass spectrometry, in conjunction with absorption and emission spectral data, and were compared with sera from photosensitive animals. In the latter, phytoporphyrin was the only metabolite detected. Calibration curves were prepared by adding different ratios of methanol and standard solutions of phytoporphyrin in methanol to diluted serum from control animals. Peak areas of fluorescence spectra were determined in samples from photosensitive animals. Pheophorbide a and pyropheophorbide a produced typical chlorin spectra, and had excitation/emission maxima of 408/669 nm and 409/669 nm, respectively. Phytoporphyrin showed a typical porphyrin fluorescence spectrum, with excitation/ emission maxima of 425/644 nm. Pyropheophorbide a and phytoporphyrin had very similar chromatographic retention times, the same chemical formula and same mass, but were distinguishable by differences in their absorption spectra. In sera from photosensitive animals, the fluorescence emission at 644 nm was shown to arise solely from phytoporphyrin and not from any other chlorophyll a metabolites. Calibration curves using sera and plasma from control animals gave reliable measurements of phytoporphyrin in the range 0.4-6 microM. The sera of facial eczema-affected cattle and sheep had concentrations of phytoporphyrin ranging from 0.4 to 1.8 and 0.9 to 2.8 microM, respectively. Haemolysed serum samples were not suitable for determination of phytoporphyrin with this method. A spectrofluorometric method for the quantification of phytoporphyrin in the blood of photosensitive animals has been validated, and can be applied to the measurement of other chlorophyll a metabolites in blood. This will be a useful tool in the further investigation of the cause and pathogenesis of idiopathic photosensitivities of farm animals.
Montei, Carolyn; McDougal, Susan; Mozola, Mark; Rice, Jennifer
2014-01-01
The Soleris Non-fermenting Total Viable Count method was previously validated for a wide variety of food products, including cocoa powder. A matrix extension study was conducted to validate the method for use with cocoa butter and cocoa liquor. Test samples included naturally contaminated cocoa liquor and cocoa butter inoculated with natural microbial flora derived from cocoa liquor. A probability of detection statistical model was used to compare Soleris results at multiple test thresholds (dilutions) with aerobic plate counts determined using the AOAC Official Method 966.23 dilution plating method. Results of the two methods were not statistically different at any dilution level in any of the three trials conducted. The Soleris method offers the advantage of results within 24 h, compared to the 48 h required by standard dilution plating methods.
USDA-ARS?s Scientific Manuscript database
Body composition indicators provide a better guidance for growth and nutritional status of the infants. This study was designed to (1) measure the body composition of the Sri Lankan infants using a reference method, the 18*O dilution method; (2) calculate the body fat content of the infants using pu...
Methods for deoxygenating biomass-derived pyrolysis oil
Brandvold, Timothy A.
2015-07-14
Methods for deoxygenating a biomass-derived pyrolysis oil are provided. A method comprising the steps of diluting the biomass-derived pyrolysis oil with a phenolic-containing diluent to form a diluted pyoil-phenolic feed is provided. The diluted pyoil-phenolic feed is contacted with a deoxygenating catalyst in the presence of hydrogen at hydroprocessing conditions effective to form a low-oxygen biomass-derived pyrolysis oil effluent.
Unveiling massive numbers of cancer-related urinary-microRNA candidates via nanowires
Yasui, Takao; Yanagida, Takeshi; Ito, Satoru; Konakade, Yuki; Takeshita, Daiki; Naganawa, Tsuyoshi; Nagashima, Kazuki; Shimada, Taisuke; Kaji, Noritada; Nakamura, Yuta; Thiodorus, Ivan Adiyasa; He, Yong; Rahong, Sakon; Kanai, Masaki; Yukawa, Hiroshi; Ochiya, Takahiro; Kawai, Tomoji; Baba, Yoshinobu
2017-01-01
Analyzing microRNAs (miRNAs) within urine extracellular vesicles (EVs) is important for realizing miRNA-based, simple, and noninvasive early disease diagnoses and timely medical checkups. However, the inherent difficulty in collecting dilute concentrations of EVs (<0.01 volume %) from urine has hindered the development of these diagnoses and medical checkups. We propose a device composed of nanowires anchored into a microfluidic substrate. This device enables EV collections at high efficiency and in situ extractions of various miRNAs of different sequences (around 1000 types) that significantly exceed the number of species being extracted by the conventional ultracentrifugation method. The mechanical stability of nanowires anchored into substrates during buffer flow and the electrostatic collection of EVs onto the nanowires are the two key mechanisms that ensure the success of the proposed device. In addition, we use our methodology to identify urinary miRNAs that could potentially serve as biomarkers for cancer not only for urologic malignancies (bladder and prostate) but also for nonurologic ones (lung, pancreas, and liver). The present device concept will provide a foundation for work toward the long-term goal of urine-based early diagnoses and medical checkups for cancer. PMID:29291244
NASA Astrophysics Data System (ADS)
Deng, Mingge; Li, Zhen; Borodin, Oleg; Karniadakis, George Em
2016-10-01
We develop a "charged" dissipative particle dynamics (cDPD) model for simulating mesoscopic electrokinetic phenomena governed by the stochastic Poisson-Nernst-Planck and the Navier-Stokes equations. Specifically, the transport equations of ionic species are incorporated into the DPD framework by introducing extra degrees of freedom and corresponding evolution equations associated with each DPD particle. Diffusion of ionic species driven by the ionic concentration gradient, electrostatic potential gradient, and thermal fluctuations is captured accurately via pairwise fluxes between DPD particles. The electrostatic potential is obtained by solving the Poisson equation on the moving DPD particles iteratively at each time step. For charged surfaces in bounded systems, an effective boundary treatment methodology is developed for imposing both the correct hydrodynamic and electrokinetics boundary conditions in cDPD simulations. To validate the proposed cDPD model and the corresponding boundary conditions, we first study the electrostatic structure in the vicinity of a charged solid surface, i.e., we perform cDPD simulations of the electrostatic double layer and show that our results are in good agreement with the well-known mean-field theoretical solutions. We also simulate the electrostatic structure and capacity densities between charged parallel plates in salt solutions with different salt concentrations. Moreover, we employ the proposed methodology to study the electro-osmotic and electro-osmotic/pressure-driven flows in a micro-channel. In the latter case, we simulate the dilute poly-electrolyte solution drifting by electro-osmotic flow in a micro-channel, hence demonstrating the flexibility and capability of this method in studying complex fluids with electrostatic interactions at the micro- and nano-scales.
Implementation of bioassay methods to improve assessment of incorporated radionuclides.
Oeh, U; Andrasi, A; Bouvier-Capely, C; De Carlan, L; Fischer, H; Franck, D; Höllriegl, V; Li, W B; Ritt, J; Roth, P; Schmitzer, Ch; Wahl, W; Zombori, P
2007-01-01
The present work which was carried out in the framework of an EU project (IDEA: Internal Dosimetry-Enhancements in Application; Contract Number: FIKR CT2001 00164) shall provide commonly acceptable guidelines for optimum performance of ICP-MS measurements with focus on urinary measurements of uranium, thorium and actinides. From the results of this work it is recommended that, whenever feasible, 24 h urine sampling should be conducted to avoid large uncertainties in the quantitation of daily urinary excretion values. For storage, urine samples should be acidified and kept frozen before analysis. Measurement of total uranium in urine by ICP-MS at physiological levels (<10 ng.l(-1)) requires no sample preparation besides UV photolysis and/or dilution. For the measurement of thorium in urine by ICP-MS, it can be concluded, that salt removal from the urine samples is not recommended. For the measurement of actinides in urine it is shown that ICP-MS is well-suited and a good alternative to alpha-spectrometry for isotopes with T1/2>5x10(4) years. In general, ICP-MS measurements are an easy, fast and cost-saving methodology. New improved measuring techniques (HR-SF-ICP-MS) with detection limits in urine of 150 pg.l(-1) (1.9 microBq.l(-1)) for 238U, 30 pg.l(-1) (2.4 microBq.l(-1)) for 235U and 100 pg.l(-1) (0.4 microBq.l(-1)) for (232)Th, respectively, meet all necessary requirements. This method should therefore become the routine technique for incorporation monitoring of workers and of members of the general public, in particular for uranium contamination.
Jardak, Marwa; Elloumi-Mseddi, Jihene; Aifa, Sami; Mnif, Sami
2017-10-02
Rosmarinus officinalis L. from Tunisia, popularly known as rosemary, is of a considerable importance for its medicinal uses and aromatic value. The aim of this study was to examine the chemical composition of Rosmarinus officinalis essential oil (ROEO) and to evaluate its antibiofilm activity on biofilm-forming bacterium and its anticancer activity on cancer cell lines. The chemical composition of Rosmarinus officinalis essential oil (ROEO) was analyzed by GC-MS and its antibacterial activity was evaluated by micro-dilution method. The antibofilm activity of ROEO was evaluated using the crystal violet test and the cytotoxicity activity was determined by the MTT assay. In this research, thirty-six compounds were identified in ROEO using GC-MS analyses. The main components were 1,8-cineole (23.56%), camphene (12.78%), camphor (12.55%) and β-pinene (12.3%). The antibacterial activity of ROEO was evaluated by micro-dilution method. The oil exhibited inhibition and bactericidal effect against two strains: Staphylococcus aureus ATCC 9144 and Staphylococcus epidermidis S61. It was found that the minimum inhibitory concentration (MIC) obtained for S. aureus and S. epidermidis ranged from 1.25 to 2.5 and from 0.312 to 0.625 μl ml -1 , respectively and the minimum bactericidal concentration (MBC) were in the order of 5 and 2.5 μl ml -1 , respectively. Furthermore, this oil showed a S. epidermidis biofilm inhibition more than 57% at a concentration of 25 μl ml -1 . The eradication of 67% of the established biofilm was observed at a concentration of 50 μl ml -1 of ROEO, whereas the dose of 25 μl ml -1 removed only 38% of preformed biofilm. ROEO strongly inhibited the proliferation of Hela and MCF-7 cells with IC 50 values of 0.011 and 0.253 μl ml -1 , respectively. Our results demonstrate that ROEO could have a potential role in the treatment of diseases related to infection by microorganisms or proliferation of cancer cells.
Microgravity alters protein phosphorylation changes during initiation of sea urchin sperm motility
NASA Technical Reports Server (NTRS)
Tash, J. S.; Bracho, G. E.
1999-01-01
European Space Agency (ESA) studies demonstrated that bull sperm swim with higher velocity in microgravity (microG) than at 1 G. Coupling between protein phosphorylation and sperm motility during activation in microG and at 1 G was examined in the ESA Biorack on two space shuttle missions. Immotile sperm were activated to swim (86-90% motility) at launch +20 h by dilution into artificial seawater (ASW). Parallel ground controls were performed 2 h after the flight experiment. Activation after 0, 30, and 60 s was terminated with electrophoresis sample buffer and samples analyzed for phosphoamino acids by Western blotting. Phosphorylation of a 130-kDa phosphothreonine-containing protein (FP130) occurred three to four times faster in microG than at 1 G. A 32-kDa phosphoserine-containing protein was significantly stimulated at 30 s but returned to 1 G control levels at 60 s. The rate of FP130 phosphorylation in microG was attenuated by D2O, suggesting that changes in water properties participate in altering signal transduction. Changes in FP130 phosphorylation triggered by the egg peptide speract were delayed in microG. These results demonstrate that previously observed effects of microG on sperm motility are coupled to changes in phosphorylation of specific flagellar proteins and that early events of sperm activation and fertilization are altered in microG.
Rossi, P; Oldner, A; Wanecek, M; Leksell, L G; Rudehill, A; Konrad, D; Weitzberg, E
2003-03-01
To compare a molecular double-indicator dilution technique with the gravimetrical reference method for measurement of extra-vascular lung water in porcine endotoxin shock. Open comparative experimental study. Animal research laboratory. In fourteen anaesthetised, mechanically ventilated landrace pigs, central and pulmonary haemodynamics as well as pulmonary gas exchange were measured. Extra-vascular lung water was quantitated gravimetrically as well as with a molecular double indicator dilution technique. Eight of these animals were subjected to endotoxaemia, the rest serving as sham controls. No difference in extra-vascular lung water was observed between the two methods in sham animals. Furthermore, extra-vascular lung water assessed with the molecular double-indicator dilution technique at the initiation of endotoxin infusion did not differ significantly from the corresponding values for sham animals. Endotoxaemia induced a hypodynamic shock with concurrent pulmonary hypertension and a pronounced deterioration in gas exchange. No increase in extra-vascular lung water was detected with the molecular double-indicator dilution technique in response to endotoxin, whereas this parameter was significantly higher when assessed with the gravimetric method. The molecular double-indicator dilution technique showed similar results as the gravimetrical method for assessment of extra-vascular lung water in non-endotoxaemic conditions. However, during endotoxin-induced lung injury the molecular double indicator dilution technique failed to detect the significant increase in extra-vascular lung water as measured by the gravimetric method. These data suggest that the molecular double indicator dilution technique may be of limited value during sepsis-induced lung injury.
Estuarine microbial food web patterns in a Lake Erie coastal wetland.
Lavrentyev, P J; McCarthy, M J; Klarer, D M; Jochem, F; Gardner, W S
2004-11-01
Composition and distribution of planktonic protists were examined relative to microbial food web dynamics (growth, grazing, and nitrogen cycling rates) at the Old Woman Creek (OWC) National Estuarine Research Reserve during an episodic storm event in July 2003. More than 150 protistan taxa were identified based on morphology. Species richness and microbial biomass measured via microscopy and flow cytometry increased along a stream-lake (Lake Erie) transect and peaked at the confluence. Water column ammonium (NH4+) uptake (0.06 to 1.82 microM N h(-1)) and regeneration (0.04 to 0.55 microM N h(-1)) rates, measured using 15NH4+ isotope dilution, followed the same pattern. Large light/dark NH4+ uptake differences were observed in the hypereutrophic OWC interior, but not at the phosphorus-limited Lake Erie site, reflecting the microbial community structural shift from net autotrophic to net heterotrophic. Despite this shift, microbial grazers (mostly choreotrich ciliates, taxon-specific growth rates up to 2.9 d(-1)) controlled nanophytoplankton and bacteria at all sites by consuming 76 to 110% and 56 to 97% of their daily production, respectively, in dilution experiments. Overall, distribution patterns and dynamics of microbial communities in OWC resemble those in marine estuaries, where plankton productivity increases along the river-sea gradient and reaches its maximum at the confluence.
Comparison of Anaerobic Susceptibility Results Obtained by Different Methods
Rosenblatt, J. E.; Murray, P. R.; Sonnenwirth, A. C.; Joyce, J. L.
1979-01-01
Susceptibility tests using 7 antimicrobial agents (carbenicillin, chloramphenicol, clindamycin, penicillin, cephalothin, metronidazole, and tetracycline) were run against 35 anaerobes including Bacteroides fragilis (17), other gram-negative bacilli (7), clostridia (5), peptococci (4), and eubacteria (2). Results in triplicate obtained by the microbroth dilution method and the aerobic modification of the broth disk method were compared with those obtained with an agar dilution method using Wilkins-Chalgren agar. Media used in the microbroth dilution method included Wilkins-Chalgren broth, brain heart infusion broth, brucella broth, tryptic soy broth, thioglycolate broth, and Schaedler's broth. A result differing by more than one dilution from the Wilkins-Chalgren agar result was considered a discrepancy, and when there was a change in susceptibility status this was termed a significant discrepancy. The microbroth dilution method using Wilkins-Chalgren broth and thioglycolate broth produced the fewest total discrepancies (22 and 24, respectively), and Wilkins-Chalgren broth, thioglycolate, and Schaedler's broth had the fewest significant discrepancies (6, 5, and 5, respectively). With the broth disk method, there were 15 significant discrepancies, although half of these were with tetracycline, which was the antimicrobial agent associated with the highest number of significant discrepancies (33), considering all of the test methods and media. PMID:464560
Method And Apparatus For Reducing Sample Dispersion In Turns And Junctions Of Micro-Channel Systems
Griffiths, Stewart K. , Nilson, Robert H.
2004-05-11
What is disclosed pertains to improvement in the performance of microchannel devices by providing turns, wyes, tees, and other junctions that produce little dispersion of a sample as it traverses the turn or junction. The reduced dispersion results from contraction and expansion regions that reduce the cross-sectional area over some portion of the turn or junction. By carefully designing the geometries of these regions, sample dispersion in turns and junctions is reduced to levels comparable to the effects of ordinary diffusion. The low dispersion features are particularly suited for microfluidic devices and systems using either electromotive force, pressure, or combinations thereof as the principle of fluid transport. Such microfluidic devices and systems are useful for separation of components, sample transport, reaction, mixing, dilution or synthesis, or combinations thereof.
Salehzadeh, Ali; Asadpour, Leila; Naeemi, Akram Sadat; Houshmand, Elham
2014-01-01
Increase in the emergence of drug -resistant pathogens led to the development of natural antimicrobials. In this study the antimicrobial effect of methanolic extracts of Sambucus ebulus and Urtica dioica on 16 skin and wound infections isolates of methicillin resistant S. aureus have been studied. Solvent extraction procedure was done using soxhlet apparatus for extracting antimicrobial agents from freeze dried plants. Antibacterial activity was measured using agar well diffusion method. The MIC of Sambucus ebulus and Urtica dioica extracts against the standard strain of S. aureus ATCC 6538 were determined using the micro dilution method at 15 mg and 20 mg respectively. All the test bacteria were found sensitive to the Sambucus ebulus extract and only one isolate was resistant to Urtica dioica extract. Extracts of Sambucus ebulus and Urtica dioica possess antibacterial potency against MRSA isolates and may be used as a natural antiseptics and antimicrobial agents in medicine.
Detection of unburned fuel as contaminant in engine oil by a gas microsensor array
NASA Astrophysics Data System (ADS)
Capone, Simonetta; Zuppa, Marzia; Presicce, Dominique S.; Epifani, Mauro; Francioso, Luca; Siciliano, Pietro; Distante, C.
2007-05-01
We developed a novel method to detect the presence of unburned diesel fuel in used diesel fuel engine oil. The method is based on the use of an array of different gas microsensors based on metal oxide thin films deposited by sol-gel technique on Si substrates. The sensor array, exposed to the volatile chemical species of different diesel fuel engine oil samples contaminated in different percentages by diesel fuel, resulted to be appreciable sensitive to them. Principal Component Analysis (PCA) and Self-Organizing Map (SOM) applied to the sensor response data-set gave a first proof of the sensor array ability to discriminate among the different diesel fuel diluted lubricating oils. Moreover, in order to get information about the headspace composition of the diesel fuel-contaminated engine oils used for gas-sensing tests, we analyzed the engine oil samples by Static Headspace Solid Phase Micro Extraction/Gas Chromatograph/Mass Spectrometer (SHS-SPME/ GC/MS).
NASA Astrophysics Data System (ADS)
Veronesi, G.; Brun, E.; Fayard, B.; Cotte, M.; Carrière, M.
2012-05-01
Micro-beam x-ray absorption fine structure spectroscopy was used to investigate rutile TiO2 nanoparticles internalized into gastrointestinal cells during their crossing of a gut model barrier. Nanoparticles diluted in culture medium tend to accumulate in cells after 48 h exposure; however, no spectral differences arise between particles in cellular and in acellular environments, as corroborated by quantitative analysis. This finding establishes that no modification of the lattice properties of the nanoparticles occurs upon interaction with the barrier. These measurements demonstrate the possibility of interrogating nanoparticles in situ within cells, suggesting a way to investigate their fate when incorporated in biological hosts.
NASA Astrophysics Data System (ADS)
Yeh, Chia-Hsien; Hung, Chia-Wei; Wu, Chun-Han; Lin, Yu-Cheng
2014-09-01
This paper presents a cross-flow filtration chip for separating blood cells (white blood cells, red blood cells, and platelets) and obtaining blood plasma from human blood. Our strategy is to flow the sample solution in parallel to the membrane, which can generate a parallel shear stress to remove the clogging microparticles on the membrane, so the pure sample solution is obtained in the reservoir. The cross-flow filtration chip includes a cross-flow layer, a Ni-Pd alloy micro-porous membrane, and a reservoir layer. The three layers are packaged in a polymethylmethacrylate (PMMA) frame to create the cross-flow filtration chip. Various dilutions of the blood sample (original, 2 × , 3 × , 5 × , and 10×), pore sizes with different diameters (1 µm, 2 µm, 4 µm, 7 µm, and 10 µm), and different flow rates (1 mL/min, 3 mL/min, 5 mL/min, 7 mL/min, and 10 mL/min) are tested to determine their effects on filtration percentage. The best filtration percentage is 96.2% when the dilution of the blood sample is 10 × , the diameter of pore size of a Ni-Pd alloy micro-porous membrane is 2 µm, and the flow rate is 10 mL/min. Finally, for the clinical tests of the immunoglobulin E (IgE) concentration, the cross-flow filtration chip is used to filter the blood of the allergy patients to obtain the blood plasma. This filtered blood plasma is compared with that obtained using the conventional centrifugation based on the enzyme-linked immunosorbent assay. The results reveal that these two blood separation methods have similar detection trends. The proposed filtration chip has the advantages of low cost, short filtration time, and easy operation and thus can be applied to the separation of microparticles, cells, bacteria, and blood.
Doing More with Less? Toward Increasing the Resolution of Protistan Grazing-rate Measurements.
NASA Astrophysics Data System (ADS)
Morison, F.; Menden-Deuer, S.
2016-02-01
The dilution method is the standard protocol to quantify phytoplankton grazing-mortality rates and has been key in developing an understanding of protistan grazing impact on ocean primary production. Although the method's extensive use has facilitated the acquisition of a global dataset, its laborious application hinders the sampling resolution needed to fill knowledge gaps remaining at the geographical, seasonal, and vertical scales, and of the effects of climate-related factors influencing grazing magnitude. Here we present a rigorous assessment of an abbreviated method known as the 2-point. We analyzed unpublished results from 77 dilution experiments performed using a series of up to 5 dilutions under a wide range of chlorophyll concentrations and temperatures. We quantified the difference between estimates of both phytoplankton growth and grazing-mortality obtained based on the full dilution series and those obtained when the number of dilutions was reduced to 2. We considered the effect of non-linearity and chlorophyll concentration, and generated quantified estimates of trade-offs when choosing the fraction of seawater in the diluted treatment. Ultimately, we provide an assessment of the reliability of the 2-point method and recommendations on how to apply it.
Kumarasamy, Barani; Manipal, Sunayana; Duraisamy, Prabu; Ahmed, Adil; Mohanaganesh, SP; Jeevika, C
2014-01-01
Objectives: Use of alternative medicine to control oral streptococci is a new topic worthy of further investigation. This study aimed to elucidate the dose-dependent anti-bacterial activity of crude aqueous extract of ripe Morinda citrifolia L. (Family: Rubiaceae) fruits against oral streptococci i.e. Streptococcus mutans and Streptococcus mitis, that cause dental caries in humans. Methods: Fresh ripe M. citrifolia fruits (750g) were ground in an electronic blender with sterile water (500ml). The crude aqueous extract was lyophilized to yield a brown colored powder. Various concentrations (1000-100μg/ ml) of the extract were tested for its antibacterial activity (Kirby and Bauer method) against whole cells of S. mutans and S. mitis. Minimum Inhibitory Concentration (MIC) was determined by micro-dilution method, using serially diluted (2 folds) fruit extract, according to the National Committee for Clinical Laboratory Standards (NCCLS). Results: Crude aqueous extract (1000μg/ ml) of ripe M. citrifolia fruits effectively inhibited the growth of S. mutans (19±0.5 mm) and S. mitis (18.6±0.3 mm) compared to the streptomycin control (21.6±0.3 mm). The growth inhibition was clearly evident with “nil” bacteriostasis, even after 48 hours of incubation at 37°C. The MIC of the extract for S. mutans and S. mitis was 125 μg and 62.5 μg, respectively. Conclusion: Our results suggest that phytochemicals naturally synthesized by M. citrifolia have an inhibitory effect on oral streptococci. Furthermore, purification and molecular characterization of the “bioactive principle” would enable us to formulate a sustainable oral hygiene product. PMID:25628701
Methods and apparatuses for deoxygenating biomass-derived pyrolysis oil
Baird, Lance Awender; Brandvold, Timothy A.
2015-10-20
Embodiments of methods and apparatuses for deoxygenating a biomass-derived pyrolysis oil are provided. In one example, a method comprises the steps of separating a low-oxygen biomass-derived pyrolysis oil effluent into a low-oxygen-pyoil organic phase stream and an aqueous phase stream. Phenolic compounds are removed from the aqueous phase stream to form a phenolic-rich diluent recycle stream. A biomass-derived pyrolysis oil stream is diluted and heated with the phenolic-rich diluent recycle stream to form a heated diluted pyoil feed stream. The heated diluted pyoil feed stream is contacted with a deoxygenating catalyst in the presence of hydrogen to deoxygenate the heated diluted pyoil feed stream.
2014-01-01
Background Lignocellulosic biomass is a renewable, naturally mass-produced form of stored solar energy. Thermochemical pretreatment processes have been developed to address the challenge of biomass recalcitrance, however the optimization, cost reduction, and scalability of these processes remain as obstacles to the adoption of biofuel production processes at the industrial scale. In this study, we demonstrate that the type of reactor in which pretreatment is carried out can profoundly alter the micro- and nanostructure of the pretreated materials and dramatically affect the subsequent efficiency, and thus cost, of enzymatic conversion of cellulose. Results Multi-scale microscopy and quantitative image analysis was used to investigate the impact of different biomass pretreatment reactor configurations on plant cell wall structure. We identify correlations between enzymatic digestibility and geometric descriptors derived from the image data. Corn stover feedstock was pretreated under the same nominal conditions for dilute acid pretreatment (2.0 wt% H2SO4, 160°C, 5 min) using three representative types of reactors: ZipperClave® (ZC), steam gun (SG), and horizontal screw (HS) reactors. After 96 h of enzymatic digestion, biomass treated in the SG and HS reactors achieved much higher cellulose conversions, 88% and 95%, respectively, compared to the conversion obtained using the ZC reactor (68%). Imaging at the micro- and nanoscales revealed that the superior performance of the SG and HS reactors could be explained by reduced particle size, cellular dislocation, increased surface roughness, delamination, and nanofibrillation generated within the biomass particles during pretreatment. Conclusions Increased cellular dislocation, surface roughness, delamination, and nanofibrillation revealed by direct observation of the micro- and nanoscale change in accessibility explains the superior performance of reactors that augment pretreatment with physical energy. PMID:24690534
Roy, M; Lee, R W; Brange, J; Dunn, M F
1990-04-05
The effects of high dilution on the 1H Fourier transform NMR spectrum of native human insulin at pH* 8.0 and 9.3 have been examined at 500 MHz resolution. The dependence of the spectrum on concentration and comparison with the spectrum of a biologically highly potent monomeric insulin mutant (SerB9----Asp) establish that at 36 microM (pH* 9.3) or 18 microM (pH* 8) and no added buffer or salts, human insulin is monomeric. Under these conditions of dilution, ionic strength, and pH*, human insulin and the SerB9----Asp mutant exhibit nearly identical 1H NMR spectra. At higher concentrations (i.e. greater than 36 microM to 0.91 mM), native human insulin dimerizes, and this aggregation causes a change in insulin conformation. Although there are many changes in the spectrum, the TyrB26 ring H3,5 proton signals located at 6.63 ppm and the methyl signal located at 0.105 ppm (characteristics of monomeric insulin) are particularly distinct signatures of the conformation change that accompanies dimerization. Magnetization transfer experiments show that the 0.105 ppm methyl signal shifts downfield to a new position at 0.45 ppm. We conclude that the 0.105 ppm methyl signal is due to a conformation in which a Leu methyl group is centered over and in van der Waals contact with the ring of an aromatic side chain. Dimerization causes a conformation change that alters this interaction, thereby causing the downfield shift. Nuclear Overhauser studies indicate that the methyl group involved is located within a cluster of aromatic side chains and that the closest ring-methyl group interaction is with the ring of PheB24.
Smith, D W; Mount, R J; Callahan, J W
1989-10-01
The cholinotoxin ethylcholine mustard aziridinium ion (AF64A) was diluted in artificial perilymph to concentrations ranging from 10-100 microM, injected unilaterally into the bulla of chinchillas, and allowed to passively diffuse across the round window membrane. Following 21-day survival, the animals were sacrificed and ears removed and embedded in epoxy for histological evaluation under both light and transmission electron microscopy. At 10 microM concentration, selective degeneration of efferent fibers was observed in the efferent terminals on outer hair cells (OHC), tunnel radial fibers, tunnel spiral bundle, and the inner spiral bundle. Serial sections of the middle turn of an animal at 10 microM concentrations showed normal efferent terminals on approximately 50% of OHCs. At the higher concentrations non-specific damage was seen in OHCs, afferents, and some supporting cells. These data suggest that low doses AF64A produces selective damage to cochlear efferent terminals and fibers in the chinchilla.
The development of a practicable method for deepfreezing of boar spermatozoa.
Larsson, K; Einarsson, S; Swensson, T
1977-03-01
The present study was made in order to develop the freezing method of Crabo & Einarsson (1971) into a practicable deep-freezing method for boar spermatozoa. Semen was concentrated before dilution and a dosewise thawing procedure for the pellet-frozen semen was utilized. Two fertility tests on altogther 68 gilts were performed. In the first trial the insemination doses contained 6x10(9) spermatozoa and the dilution rate before cooling was 3:2 with a total dilution before freezing of 3:7. In the second trial the insemination doses contained 4.5x10(9) spermatozoa, primary dilution was 3:3 and final dilution 3:7. The pregnancy rate in trial 1 was 53% and in trial 2 72%. Mean litter size in pregnant gilts was 6.5 in trial 1 and 9.7 in trial 2. The difference in ratio of foetuses to c.l. in pregnant gilts between the trials was highly significant. The different dilution procedures are discussed and the lower fertility of semen frozen in trial 1 is suggested to be due to a shortened fertile life of spermatozoa so treated. The freezing method utilized in trial 2 is considered to be practically acceptable and the results are concluded to be satisfactory. A detailed description of the method and the equipment utilized can be requested from the authors.
Production and distribution of dilute species in semiconducting materials
James, Ralph B.; Camarda, Giuseppe; Bolotnikov, Aleksey E.; Hossain, Anwar; Yang, Ge; Kim, Kihyun
2016-09-06
Technologies are described effective to implement systems and methods of producing a material. The methods comprise receiving a tertiary semiconductor sample with a dilute species. The sample has two ends. The first end of the sample includes a first concentration of the dilute species lower than a second concentration of the dilute species in the second end of the sample. The method further comprises heating the sample in a chamber. The chamber has a first zone and a second zone. The first zone having a first temperature higher than a second temperature in the second zone. The sample is orientated such that the first end is in the first zone and the second end is in the second zone.
Bailey, Tom A.
1983-01-01
The reliability, reproducibility, and usefulness of three screening methods -- the cellophane transfer, the agar plug transfer, and the agar dilution -- to screen aquatic fungicides were evaluated. Achlya flagellata and Saprolegnia hypogyna were exposed to 1, 10, and 100 mg/L of malachite green to test each method. The cellophane transfer and agar plug transfer techniques had similar reliability and reproducibility in rating fungicidal activity, and were both superior to the agar dilution technique. The agar plug transfer and agar dilution techniques adequately projected in vivo activity of malachite green, but the cellophane transfer technique overestimated its activity. Overall, the agar plug transfer technique most accurately rated the activity of malachite green and was the easiest test to perform. It therefore appears to be the method of choice for testing aquatic fungicides.
Multi-laboratory survey of qPCR enterococci analysis method performance
Quantitative polymerase chain reaction (qPCR) has become a frequently used technique for quantifying enterococci in recreational surface waters, but there are several methodological options. Here we evaluated how three method permutations, type of mastermix, sample extract dilution and use of controls in results calculation, affect method reliability among multiple laboratories with respect to sample interference. Multiple samples from each of 22 sites representing an array of habitat types were analyzed using EPA Method 1611 and 1609 reagents with full strength and five-fold diluted extracts. The presence of interference was assessed three ways: using sample processing and PCR amplifications controls; consistency of results across extract dilutions; and relative recovery of target genes from spiked enterococci in water sample compared to control matrices with acceptable recovery defined as 50 to 200%. Method 1609, which is based on an environmental mastermix, was found to be superior to Method 1611, which is based on a universal mastermix. Method 1611 had over a 40% control assay failure rate with undiluted extracts and a 6% failure rate with diluted extracts. Method 1609 failed in only 11% and 3% of undiluted and diluted extracts analyses. Use of sample processing control assay results in the delta-delta Ct method for calculating relative target gene recoveries increased the number of acceptable recovery results. Delta-delta tended to bias recoveries fr
Novel method for on-road emission factor measurements using a plume capture trailer.
Morawska, L; Ristovski, Z D; Johnson, G R; Jayaratne, E R; Mengersen, K
2007-01-15
The method outlined provides for emission factor measurements to be made for unmodified vehicles driving under real world conditions at minimal cost. The method consists of a plume capture trailer towed behind a test vehicle. The trailer collects a sample of the naturally diluted plume in a 200 L conductive bag and this is delivered immediately to a mobile laboratory for subsequent analysis of particulate and gaseous emissions. The method offers low test turnaround times with the potential to complete much larger numbers of emission factor measurements than have been possible using dynamometer testing. Samples can be collected at distances up to 3 m from the exhaust pipe allowing investigation of early dilution processes. Particle size distribution measurements, as well as particle number and mass emission factor measurements, based on naturally diluted plumes are presented. A dilution profile relating the plume dilution ratio to distance from the vehicle tail pipe for a diesel passenger vehicle is also presented. Such profiles are an essential input for new mechanistic roadway air quality models.
NASA Astrophysics Data System (ADS)
Ploykrachang, K.; Hasegawa, J.; Kondo, K.; Fukuda, H.; Oguri, Y.
2014-07-01
We have developed a micro-XRF system based on a proton-induced quasimonochromatic X-ray (QMXR) microbeam for in vivo measurement of biological samples. A 2.5-MeV proton beam impinged normally on a Cu foil target that was slightly thicker than the proton range. The emitted QMXR behind the Cu target was focused with a polycapillary X-ray half lens. For application to analysis of wet or aquatic samples, we prepared a QMXR beam with an incident angle of 45° with respect to the horizontal plane by using a dipole magnet in order to bend the primary proton beam downward by 45°. The focal spot size of the QMXR microbeam on a horizontal sample surface was evaluated to be 250 × 350 μm by a wire scanning method. A microscope camera with a long working distance was installed perpendicular to the sample surface to identify the analyzed position on the sample. The fluorescent radiation from the sample was collected by a Si-PIN photodiode X-ray detector. Using the setup above, we were able to successfully measure the accumulation and distribution of Co in the leaves of a free-floating aquatic plant on a dilute Co solution surface.
1989-11-07
dialyzed against the appropriate medium prior to dilution into the bath. The buccal ganglion in Aplysia contain two large, identified cholinergic neurons...transmitters. Micro-injection of nanomolar final concentrations of BoNT A (Fig. 2A) or B (Fig. 2B) into pre-synaptic cholinergic neurons in the buccal ...already been made to use rat pituitary cells together with patch pipette techniques in this study; this system has facilitated intracellular
Improvement in Microstructure Performance of the NiCrBSi Reinforced Coating on TA15 Titanium Alloy
NASA Astrophysics Data System (ADS)
Peng, Li
2012-10-01
This work is based on the dry sliding wear of NiCrBSi reinforced coating deposited on TA15 titanium alloy using the laser cladding technique, the parameters of which were such as to provide almost crack-free coatings with minimum dilution and very low porosity. SEM results indicated that a laser clad coating with metallurgical joint to the substrate was formed. Compared with TA15 substrate, an improvement of the micro-hardness and wear resistance was observed for this composite coating. Rare earth oxide Y2O3 was beneficial in producing of the amorphous phases in laser clad coating. With addition of Y2O3, more amorphous alloys were produced, which increased the micro-hardness and wear resistance of the coating.
Salleh, Wan Mohd Nuzul Hakimi Wan; Ahmad, Farediah; Sirat, Hasnah Mohd; Yen, Khong Heng
2012-01-01
The essential oils obtained by hydrodistillation from the fresh leaf and stem of Piper porphyrophyllum N.E. Br. were analyzed by GC and GC/MS. Thirty four constituents were identified in the leaf oil, while thirty eight constituents were identified in the stems oil. The most abundant components in the leaf oil included bicyclogermacrene (14.7 %), α-copaene (13.2 %) and β-phellandrene (9.5 %) while sabinene (15.5 %), bicyclogermacrene (12.3 %) and α-copaene (8.1 %) were the main constituents in the stem oil. The evaluation of antibacterial activity by using micro-dilution method revealed that both oils were moderately active against all the Gram-positive bacteria (Staphylococcus aureus, Bacillus subtilis) and Gram-negative bacteria (Pseudomonas aeruginosa, Pseudomonas putida and Escherichia coli) with minimum inhibitory concentration (MIC) values in the range 125-1000 µg/ml. PMID:27418915
Chen, Zhifen; He, Daohang; Deng, Jingdan; Zhu, Jiaying; Mao, Qiuping
2015-01-01
The essential oil of fresh leaves from Agathis dammara (Lamb.) Rich was extracted using hydro-distillation, and GC-FID and GC-MS were used to analyse the essential oil. Nineteen compounds were identified, among which the major components were limonene (36.81%), β-bisabolene (33.43%) and β-myrcene (25.48%). In the antibacterial test, disc diffusion method and micro-well dilution assay proved that the essential oil had significant antibacterial activities. The inhibition zones against Staphylococcus aureus and Pseudomonas aeruginosa were 23.7 and 23 mm, respectively, which demonstrated that the inhibition effects were greater than positive control (10 μg/disc streptomycin). And the lowest MIC value of the essential oil was found against S. aureus (1.25 mg/mL) and Bacillus subtilis (1.25 mg/mL). This is the first report on the antibacterial activities of A. dammara essential oil.
Ait Said, L; Zahlane, K; Ghalbane, I; El Messoussi, S; Romane, A; Cavaleiro, C; Salgueiro, L
2015-01-01
The aim of this study was to analyse the composition of the essential oil (EO) of Lavandula coronopifolia from Morocco and to evaluate its in vitro antibacterial activity against antibiotic-resistant bacteria isolated from clinical infections. The antimicrobial activity was assessed by a broth micro-well dilution method using multiresistant clinical isolates of 11 pathogenic bacteria: Klebsiella pneumoniae subsp. pneumoniae, Klebsiella ornithinolytica, Escherichia coli, Enterobacter cloacae, Enterobacter aerogenes, Providencia rettgeri, Citrobacter freundii, Hafnia alvei, Salmonella spp., Acinetobacter baumannii and methicillin-resistant Staphylococcus aureus. The main compounds of the oil were carvacrol (48.9%), E-caryophyllene (10.8%) and caryophyllene oxide (7.7%). The oil showed activity against all tested strains with minimal inhibitory concentration (MIC) values ranging between 1% and 4%. For most of the strains, the MIC value was equivalent to the minimal bactericidal concentration value, indicating a clear bactericidal effect of L. coronopifolia EO.
Microvolume protein concentration determination using the NanoDrop 2000c spectrophotometer.
Desjardins, Philippe; Hansen, Joel B; Allen, Michael
2009-11-04
Traditional spectrophotometry requires placing samples into cuvettes or capillaries. This is often impractical due to the limited sample volumes often used for protein analysis. The Thermo Scientific NanoDrop 2000c Spectrophotometer solves this issue with an innovative sample retention system that holds microvolume samples between two measurement surfaces using the surface tension properties of liquids, enabling the quantification of samples in volumes as low as 0.5-2 microL. The elimination of cuvettes or capillaries allows real time changes in path length, which reduces the measurement time while greatly increasing the dynamic range of protein concentrations that can be measured. The need for dilutions is also eliminated, and preparations for sample quantification are relatively easy as the measurement surfaces can be simply wiped with laboratory wipe. This video article presents modifications to traditional protein concentration determination methods for quantification of microvolume amounts of protein using A280 absorbance readings or the BCA colorimetric assay.
Voukeng, Igor K; Beng, Veronique P; Kuete, Victor
2017-07-25
Multidrug resistant (MDR) bacteria are responsible for therapeutic failure and there is an urgent need for novels compounds efficient on them. Eleven methanol extracts from seven Cameroonian medicinal plants were tested for their antibacterial activity using broth micro-dilution method against 36 MDR bacterial strains including Escherichia coli, Enterobacter aerogenes, Enterobacter cloacae, Klebsiella pneumoniae, Providencia stuartii, Pseudomonas aeruginosa and Staphylococcus aureus. Euphorbia prostrata extract was found active against all the 36 tested bacteria including Gram-negative phenotypes over-expressing efflux pumps such as P. aeruginosa PA124, E. aerogenes CM64 and E. coli AG102. E. prostrata had minimal inhibitory concentrations values between 128 and 256 µg/mL on 55.55% of the studied microorganisms. Other plants extract displayed selective antibacterial activity. Results obtained in this study highlight the antibacterial potential of the tested plants and the possible use of E. prostrata to combat bacterial infections including MDR phenotypes.
Magnetofluidic concentration and separation of non-magnetic particles using two magnet arrays
Hejazian, Majid
2016-01-01
The present paper reports the use of diluted ferrofluid and two arrays of permanent magnets for the size-selective concentration of non-magnetic particles. The micro magnetofluidic device consists of a straight channels sandwiched between two arrays of permanent magnets. The permanent magnets create multiple capture zones with minimum magnetic field strength along the channel. The complex interaction between magnetic forces and hydrodynamic force allows the device to operate in different regimes suitable for concentration of non-magnetic particles with small difference in size. Our experimental results show that non-magnetic particles with diameters of 3.1 μm and 4.8 μm can be discriminated and separated with this method. The results from this study could be used as a guide for the design of size-sensitive separation devices for particle and cell based on negative magnetophoresis. PMID:27478527
NASA Astrophysics Data System (ADS)
Peng, Jiaoyu; Bian, Shaoju; Lin, Feng; Wang, Liping; Dong, Yaping; Li, Wu
2017-10-01
The synthesis of pinnoite (MgB2O(OH)6) in boron-containing brine was established with a novel dilution method. Effects of temperature, precipitation time, boron concentration and mass dilution ratio on the formation of pinnoite were investigated. The products obtained were characterized by X-ray diffraction (XRD), Raman, thermogravimetric and differential scanning calorimeter (TG-DSC), and scanning electron microscopy. The transformation mechanism of pinnoite with different dilution ratios was assumed by studying the crystal growth of pinnoite. The results showed that pinnoite was synthesized above 60 °C in the diluted brine. There were two reaction steps - precipitation of amorphous solid and the formation of pinnoite crystals - during the whole reaction process of pinnoite when the dilution ratio is more than 1.0 at 80 °C. While in the 0.5 diluted brine, only one reaction step of pinnoite crystal formation was observed and its transformation mechanism was discussed based on dissociation of polyborates in brine. Besides, the origin of pinnoite mineral deposited on salt lake bottom was proposed.
21 CFR 175.270 - Poly(vinyl fluoride) resins.
Code of Federal Regulations, 2014 CFR
2014-04-01
...(vinyl fluoride) basic resins have an intrinsic viscosity of not less than 0.75 deciliter per gram as determined by ASTM method D1243-79, “Standard Test Method for Dilute Solution Viscosity of Vinyl Chloride... (ASTM method D1243-79, “Standard Test Method for Dilute Solution Viscosity of Vinyl Chloride Polymers...
[A non-invasive portable blood-glucose monitoring system: sampling of suction effusion fluid].
Arai, T; Kayashima, S; Kikuchi, M; Kaneyoshi, A; Itoh, N
1995-04-01
We developed a new portable transcutaneous blood glucose monitoring system using non-invasive collection of suction effusion fluid (SEF) from human skin. A ion sensitive field effect transistor (ISFET) sensor was employed to measure glucose concentration in a very small quantity of the SEF. The system was composed of a couple of portions. One structure was a suction cell, and the other was a main frame. The suction cell included the ISFET glucose sensor, a dilution mechanism, and a sucking interface to human skin. The main frame contained a dilution solution reservoir, a liquid waste reservoir, a fluid pump, a vacuum pump, a micro processor, batteries, and a user interface. The system is self-contained for portable usage during up to 6 hrs monitoring. This system may be the first blood glucose monitoring equipment which does not use blood sampling.
Assessing the Accuracy of the Tracer Dilution Method with Atmospheric Dispersion Modeling
NASA Astrophysics Data System (ADS)
Taylor, D.; Delkash, M.; Chow, F. K.; Imhoff, P. T.
2015-12-01
Landfill methane emissions are difficult to estimate due to limited observations and data uncertainty. The mobile tracer dilution method is a widely used and cost-effective approach for predicting landfill methane emissions. The method uses a tracer gas released on the surface of the landfill and measures the concentrations of both methane and the tracer gas downwind. Mobile measurements are conducted with a gas analyzer mounted on a vehicle to capture transects of both gas plumes. The idea behind the method is that if the measurements are performed far enough downwind, the methane plume from the large area source of the landfill and the tracer plume from a small number of point sources will be sufficiently well-mixed to behave similarly, and the ratio between the concentrations will be a good estimate of the ratio between the two emissions rates. The mobile tracer dilution method is sensitive to different factors of the setup such as placement of the tracer release locations and distance from the landfill to the downwind measurements, which have not been thoroughly examined. In this study, numerical modeling is used as an alternative to field measurements to study the sensitivity of the tracer dilution method and provide estimates of measurement accuracy. Using topography and wind conditions for an actual landfill, a landfill emissions rate is prescribed in the model and compared against the emissions rate predicted by application of the tracer dilution method. Two different methane emissions scenarios are simulated: homogeneous emissions over the entire surface of the landfill, and heterogeneous emissions with a hot spot containing 80% of the total emissions where the daily cover area is located. Numerical modeling of the tracer dilution method is a useful tool for evaluating the method without having the expense and labor commitment of multiple field campaigns. Factors tested include number of tracers, distance between tracers, distance from landfill to transect path, and location of tracers with respect to the hot spot. Results show that location of the tracers relative to the hot spot of highest landfill emissions makes the largest difference in accuracy of the tracer dilution method.
Particles size distribution in diluted magnetic fluids
NASA Astrophysics Data System (ADS)
Yerin, Constantine V.
2017-06-01
Changes in particles and aggregates size distribution in diluted kerosene based magnetic fluids is studied by dynamic light scattering method. It has been found that immediately after dilution in magnetic fluids the system of aggregates with sizes ranging from 100 to 250-1000 nm is formed. In 50-100 h after dilution large aggregates are peptized and in the sample stationary particles and aggregates size distribution is fixed.
Ceçen, F; Yangin, C
2000-12-01
This study examined the determination of BOD in landfill leachates by dilution (D-method) and manometric methods (M-method). The differences in results were discussed based on statistical tests. The effects of sample dilution, seeding, chloride and total Kjeldahl nitrogen (TKN) level were examined. The M-method was found to be more sensitive to increases in chloride and TKN concentrations. However, in the M-method the positive interference of nitrogenous BOD (NBOD) to carbonaceous BOD (CBOD) was more successfully prevented. The BOD rate constant k and the ultimate BOD (BODu) were estimated by non-linear regression. With the M-method these parameters could be more reliably estimated than the D-method. Suggestions were made for BOD analyses in landfill leachates in future studies.
Polidori, David; Rowley, Clarence
2014-07-22
The indocyanine green dilution method is one of the methods available to estimate plasma volume, although some researchers have questioned the accuracy of this method. We developed a new, physiologically based mathematical model of indocyanine green kinetics that more accurately represents indocyanine green kinetics during the first few minutes postinjection than what is assumed when using the traditional mono-exponential back-extrapolation method. The mathematical model is used to develop an optimal back-extrapolation method for estimating plasma volume based on simulated indocyanine green kinetics obtained from the physiological model. Results from a clinical study using the indocyanine green dilution method in 36 subjects with type 2 diabetes indicate that the estimated plasma volumes are considerably lower when using the traditional back-extrapolation method than when using the proposed back-extrapolation method (mean (standard deviation) plasma volume = 26.8 (5.4) mL/kg for the traditional method vs 35.1 (7.0) mL/kg for the proposed method). The results obtained using the proposed method are more consistent with previously reported plasma volume values. Based on the more physiological representation of indocyanine green kinetics and greater consistency with previously reported plasma volume values, the new back-extrapolation method is proposed for use when estimating plasma volume using the indocyanine green dilution method.
Capesius, Joseph P.; Sullivan, Joseph R.; O'Neill, Gregory B.; Williams, Cory A.
2005-01-01
Accurate ice-affected streamflow records are difficult to obtain for several reasons, which makes the management of instream-flow water rights in the wintertime a challenging endeavor. This report documents a method to improve ice-affected streamflow records for two gaging stations in Colorado. In January and February 2002, the U.S. Geological Survey, in cooperation with the Colorado Water Conservation Board, conducted an experiment using a sodium chloride tracer to measure streamflow under ice cover by the tracer-dilution discharge method. The purpose of this study was to determine the feasibility of obtaining accurate ice-affected streamflow records by using a sodium chloride tracer that was injected into the stream. The tracer was injected at two gaging stations once per day for approximately 20 minutes for 25 days. Multiple-parameter water-quality sensors at the two gaging stations monitored background and peak chloride concentrations. These data were used to determine discharge at each site. A comparison of the current-meter streamflow record to the tracer-dilution streamflow record shows different levels of accuracy and precision of the tracer-dilution streamflow record at the two sites. At the lower elevation and warmer site, Brandon Ditch near Whitewater, the tracer-dilution method overestimated flow by an average of 14 percent, but this average is strongly biased by outliers. At the higher elevation and colder site, Keystone Gulch near Dillon, the tracer-dilution method experienced problems with the tracer solution partially freezing in the injection line. The partial freezing of the tracer contributed to the tracer-dilution method underestimating flow by 52 percent at Keystone Gulch. In addition, a tracer-pump-reliability test was conducted to test how accurately the tracer pumps can discharge the tracer solution in conditions similar to those used at the gaging stations. Although the pumps were reliable and consistent throughout the 25-day study period, the pumps underdischarged the tracer by 5.8-15.9 percent as compared to the initial pumping rate setting, which may explain some of the error in the tracer-dilution streamflow record as compared to current-meter streamflow record.
Deminice, R; Rosa, F T; Pfrimer, K; Ferrioli, E; Jordao, A A; Freitas, E
2016-02-01
This study aimed to evaluate changes in total body water (TBW) in soccer athletes using a deuterium oxide dilution method and bioelectrical impedance (BIA) formulas after 7 days of creatine supplementation. In a double-blind controlled manner, 13 healthy (under-20) soccer players were divided randomly in 2 supplementation groups: Placebo (Pla, n=6) and creatine supplementation (CR, n=7). Before and after the supplementation period (0.3 g/kg/d during 7 days), TBW was determined by deuterium oxide dilution and BIA methods. 7 days of creatine supplementation lead to a large increase in TBW (2.3±1.0 L) determined by deuterium oxide dilution, and a small but significant increase in total body weight (1.0±0.4 kg) in Cr group compared to Pla. The Pla group did not experience any significant changes in TBW or body weight. Although 5 of 6 BIA equations were sensitive to determine TBW changes induced by creatine supplementation, the Kushner et al. 16 method presented the best concordance levels when compared to deuterium dilution method. In conclusion, 7-days of creatine supplementation increased TBW determined by deuterium oxide dilution or BIA formulas. BIA can be useful to determine TBW changes promoted by creatine supplementation in soccer athletes, with special concern for formula choice. © Georg Thieme Verlag KG Stuttgart · New York.
Biodiesel Impact on Engine Lubricant Dilution During Active Regeneration of Aftertreatment Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
He, X.; Williams, A.; Christensen, E.
Experiments were conducted with ultra low sulfur diesel (ULSD) and 20% biodiesel blends (B20) to compare lube oil dilution levels and lubricant properties for systems using late in-cylinder fuel injection for aftertreatment regeneration. Lube oil dilution was measured by gas chromatography (GC) following ASTM method D3524 to measure diesel content, by Fourier transform infrared (FTIR) spectrometry following a modified ASTM method D7371 to measure biodiesel content, and by a newly developed back-flush GC method that simultaneously measures both diesel and biodiesel. Heavy-duty (HD) engine testing was conducted on a 2008 6.7L Cummins ISB equipped with a diesel oxidation catalyst (DOC)more » and diesel particle filter (DPF). Stage one of engine testing consisted of 10 consecutive repeats of a forced DPF regeneration event. This continuous operation with late in-cylinder fuel injection served as a method to accelerate lube-oil dilution. Stage two consisted of 16 hours of normal engine operation over a transient test cycle, which created an opportunity for any accumulated fuel in the oil sump to evaporate. Light duty (LD) vehicle testing was conducted on a 2010 VW Jetta equipped with DOC, DPF and a NOx storage catalyst (NSC). Vehicle testing comprised approximately 4,000 miles of operation on a mileage-accumulation dynamometer (MAD) using the U.S. Environmental Protection Agency's Highway Fuel Economy Cycle because of the relatively low engine oil and exhaust temperatures, and high DPF regeneration frequency of this cycle relative to other cycles examined. Comparison of the lube oil dilution analysis methods suggests that D3524 does not measure dilution by biodiesel. The new back-flush GC method provided analysis for both diesel and biodiesel, in a shorter time and with lower detection limit. Thus all lube oil dilution results in this paper are based on this method. Analysis of the HD lube-oil samples showed only 1.5% to 1.6% fuel dilution for both fuels during continuous operation under DPF regeneration events. During the second stage of HD testing, the ULSD lube-oil dilution levels fell from 1.5% to 0.8%, while for B20, lube-oil dilution levels fell from 1.6% to 1.0%, but the fuel in the oil was 36% biodiesel. For the LD vehicle tests, the frequency of DPF regeneration events was observed to be the same for both ULSD and B20. No significant difference between the two fuels' estimated soot loading was detected by the engine control unit (ECU), although a 23% slower rate of increase in differential pressure across DPF was observed with B20. It appears that the ECU estimated soot loading is based on the engine map, not taking advantage of the lower engine-out particulate matter from the use of biodiesel. After 4,000 miles of LD vehicle operation with ULSD, fuel dilution in the lube-oil samples showed total dilution levels of 4.1% diesel. After 4,000 miles of operation with B20, total fuel in oil dilution levels were 6.7% consisting of 3.6% diesel fuel and 3.1% biodiesel. Extrapolation to the 10,000-mile oil drain interval with B20 suggests that the total fuel content in the oil could reach 12%, compared to 5% for operation on ULSD. Analysis of the oil samples also included measurement of total acid number, total base number, viscosity, soot, metals and wear scar; however, little difference in these parameters was noted.« less
Taylor, Diane M; Chow, Fotini K; Delkash, Madjid; Imhoff, Paul T
2016-10-01
Landfills are a significant contributor to anthropogenic methane emissions, but measuring these emissions can be challenging. This work uses numerical simulations to assess the accuracy of the tracer dilution method, which is used to estimate landfill emissions. Atmospheric dispersion simulations with the Weather Research and Forecast model (WRF) are run over Sandtown Landfill in Delaware, USA, using observation data to validate the meteorological model output. A steady landfill methane emissions rate is used in the model, and methane and tracer gas concentrations are collected along various transects downwind from the landfill for use in the tracer dilution method. The calculated methane emissions are compared to the methane emissions rate used in the model to find the percent error of the tracer dilution method for each simulation. The roles of different factors are examined: measurement distance from the landfill, transect angle relative to the wind direction, speed of the transect vehicle, tracer placement relative to the hot spot of methane emissions, complexity of topography, and wind direction. Results show that percent error generally decreases with distance from the landfill, where the tracer and methane plumes become well mixed. Tracer placement has the largest effect on percent error, and topography and wind direction both have significant effects, with measurement errors ranging from -12% to 42% over all simulations. Transect angle and transect speed have small to negligible effects on the accuracy of the tracer dilution method. These tracer dilution method simulations provide insight into measurement errors that might occur in the field, enhance understanding of the method's limitations, and aid interpretation of field data. Copyright © 2016 Elsevier Ltd. All rights reserved.
Jin, Rong; Liu, Guorui; Zheng, Minghui; Fiedler, Heidelore; Jiang, Xiaoxu; Yang, Lili; Wu, Xiaolin; Xu, Yang
2017-08-04
Isotopic dilution gas chromatography combined with high resolution mass spectrometry (GC/HRMS) has overwhelming advantages with respect to the accuracy of congener-specific ultratrace analysis of complex persistent organic pollutants (POPs) in environmental matrices. However, an isotopic dilution GC/HRMS method for analysis of chlorinated and brominated polycyclic aromatic hydrocarbons (Cl-PAHs and Br-PAHs) using 13 C-labelled congeners as internal standards has not been established. In this study, a method for identification and quantification of 38 congeners of Cl-PAHs and Br-PAHs in atmosphere and stack gas samples from waste incinerators was developed using the isotopic dilution GC/HRMS technique. The instrumental detection limits of the GC/HRMS method ranged from 0.2pg to 1.8pg for Cl-PAH congeners, and 0.7pg to 2.7pg for Br-PAH congeners, which were about three orders of magnitude lower than those of the GC/quadrupole MS method. This new method developed was also the first to enable determination of Cl-PAH and Br-PAH homologs comprising congeners with the same molecular skeleton and chlorine or bromine substitution numbers. Among the detected congeners, seven Cl-PAH congeners and thirteen Br-PAH congeners that were abundant in the atmosphere and stack gases released from waste incinerators were firstly detected in real samples and reported using the established isotopic dilution GC/HRMS method. The developed isotopic dilution GC/HRMS is significant and needed for better studying the environmental behavior and health risk of Cl-PAHs and Br-PAHs. Copyright © 2017 Elsevier B.V. All rights reserved.
Rapid determination of fumigant and industrial chemical residues in food.
Daft, J L
1988-01-01
A gas chromatographic (GC) method is described for the determination of 22 fumigant and industrial chemical residues in a variety of foods. The fumigants and industrial chemicals determined are methyl bromide, methylene chloride, carbon disulfide, chloroform, 1,1-dichloroethane, ethylene dichloride, methyl chloroform, carbon tetrachloride, methylene bromide, propylene dichloride, 2,3-dichloropropene, trichloroethylene, 1,3-dichloropropylene, 1,1,2-trichloroethane, chloropicrin, ethylene dibromide, tetrachloroethylene, propylene dibromide, 1,1,2,2-tetrachloroethane, p-dichlorobenzene, o-dichlorobenzene, and 1,2-dibromo-3-chloropropane. Except for the latter three, the fumigants are determined at 90 degrees C on 3.6 m 20% loaded OV-101 columns with electron-capture and Hall-electroconductivity detectors. The other 3 compounds (o-dichlorobenzene, p-dichlorobenzene, and 1,2-dibromo-3-chloropropane), which elute beyond 30 min on the above columns, are determined at 90 degrees C on 1.8 m 5% loaded OV-101 columns with the same detectors. The ng/g-level fortifications have an overall mean analyte recovery of 70% and a coefficient of variation of 40%. The variety of foods examined includes both fatty and nonfatty food types (e.g., off-the-shelf cooked and uncooked grain-based items, dairy products, fresh and canned fruits and vegetables, and meats). Samples are extracted and cleaned up according to fat content and food type. Samples containing less than 71% fat are extracted by using an aqueous: nonaqueous shakeout (20% acetone solution under isooctane). Most extracts (isooctanes) are analyzed directly. Extracts from samples containing from 21 to 70% fat (e.g., ground beef, pecans, and corn chips) are cleaned up further on micro-Florisil columns to remove excess fat. A few other samples containing more than 71% fat or oil (e.g., butter, salad dressing, and vegetable oil) are diluted directly in isooctane and, depending on the degree of dilution, can be cleaned up further on micro-Florisil columns. Also, clear beverages (e.g., soda and tea) are extracted directly with isooctane. These extraction and cleanup techniques were tested on 231 different table-ready foods. Three-hundred incurred residues of 10 different fumigants were found in 138 items examined; 93 items had no detectable residues. The main advantage of the method is rapid semiquantitative determination of multiple fumigants from all food types.
Methods for deoxygenating biomass-derived pyrolysis oil
Baird, Lance Awender; Brandvold, Timothy A.
2015-06-30
Methods for deoxygenating a biomass-derived pyrolysis oil are provided. A method for deoxygenating a biomass-derived pyrolysis oil comprising the steps of combining a biomass-derived pyrolysis oil stream with a heated low-oxygen-pyoil diluent recycle stream to form a heated diluted pyoil feed stream is provided. The heated diluted pyoil feed stream has a feed temperature of about 150.degree. C. or greater. The heated diluted pyoil feed stream is contacted with a first deoxygenating catalyst in the presence of hydrogen at first hydroprocessing conditions effective to form a low-oxygen biomass-derived pyrolysis oil effluent.
Detection of Toxoplasma oocysts from soil by modified sucrose flotation and PCR methods.
Matsuo, Junji; Kimura, Daisuke; Rai, Shiba Kumar; Uga, Shoji
2004-06-01
A detection method of Toxoplasma gondii oocysts from soil was evaluated using the sucrose flotation technique with modification involving addition of 0.1% gelatin into washing and floating solutions. PCR was performed on untreated samples and after treatment with polyvinylpyrrolidone (PVP), heating and cooling, and NaCl. The addition of gelatin in the sucrose solution yielded a higher number of oocysts. A very thin band was observed when DNA extract was diluted to 1:1024, indicating the presence of PCR inhibitor in the soil. PCR performed on untreated DNA, on PVP-treated, and on PVP-treated with heating and cooling without added bovine serum albumin (BSA) showed a band only at higher dilutions (1:1024 and 1:512) but at a much lower dilution (1:8) with BSA. In contrast, DNA treated with all three agents showed a band at a much lower dilution (1:64), even without added BSA, and no dilution was required when BSA was added. The PCR inhibitors present in the soil were removed by employing various treatment procedures during DNA extraction, and BSA in PCR. Furthermore, the detection limit with the method was 1 oocyst/g of soil, indicating that this method is useful in epidemiological studies.
A method for predicting optimized processing parameters for surfacing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dupont, J.N.; Marder, A.R.
1994-12-31
Welding is used extensively for surfacing applications. To operate a surfacing process efficiently, the variables must be optimized to produce low levels of dilution with the substrate while maintaining high deposition rates. An equation for dilution in terms of the welding variables, thermal efficiency factors, and thermophysical properties of the overlay and substrate was developed by balancing energy and mass terms across the welding arc. To test the validity of the resultant dilution equation, the PAW, GTAW, GMAW, and SAW processes were used to deposit austenitic stainless steel onto carbon steel over a wide range of parameters. Arc efficiency measurementsmore » were conducted using a Seebeck arc welding calorimeter. Melting efficiency was determined based on knowledge of the arc efficiency. Dilution was determined for each set of processing parameters using a quantitative image analysis system. The pertinent equations indicate dilution is a function of arc power (corrected for arc efficiency), filler metal feed rate, melting efficiency, and thermophysical properties of the overlay and substrate. With the aid of the dilution equation, the effect of processing parameters on dilution is presented by a new processing diagram. A new method is proposed for determining dilution from welding variables. Dilution is shown to depend on the arc power, filler metal feed rate, arc and melting efficiency, and the thermophysical properties of the overlay and substrate. Calculated dilution levels were compared with measured values over a large range of processing parameters and good agreement was obtained. The results have been applied to generate a processing diagram which can be used to: (1) predict the maximum deposition rate for a given arc power while maintaining adequate fusion with the substrate, and (2) predict the resultant level of dilution with the substrate.« less
Single-molecule dilution and multiple displacement amplification for molecular haplotyping.
Paul, Philip; Apgar, Josh
2005-04-01
Separate haploid analysis is frequently required for heterozygous genotyping to resolve phase ambiguity or confirm allelic sequence. We demonstrate a technique of single-molecule dilution followed by multiple strand displacement amplification to haplotype polymorphic alleles. Dilution of DNA to haploid equivalency, or a single molecule, is a simple method for separating di-allelic DNA. Strand displacement amplification is a robust method for non-specific DNA expansion that employs random hexamers and phage polymerase Phi29 for double-stranded DNA displacement and primer extension, resulting in high processivity and exceptional product length. Single-molecule dilution was followed by strand displacement amplification to expand separated alleles to microgram quantities of DNA for more efficient haplotype analysis of heterozygous genes.
Feng, Yunzi; Cai, Yu; Sun-Waterhouse, Dongxiao; Cui, Chun; Su, Guowan; Lin, Lianzhu; Zhao, Mouming
2015-11-15
Aroma extract dilution analysis (AEDA) is widely used for the screening of aroma-active compounds in gas chromatography-olfactometry (GC-O). In this study, three aroma dilution methods, (I) using different test sample volumes, (II) diluting samples, and (III) adjusting the GC injector split ratio, were compared for the analysis of volatiles by using HS-SPME-AEDA. Results showed that adjusting the GC injector split ratio (III) was the most desirable approach, based on the linearity relationships between Ln (normalised peak area) and Ln (normalised flavour dilution factors). Thereafter this dilution method was applied in the analysis of aroma-active compounds in Japanese soy sauce and 36 key odorants were found in this study. The most intense aroma-active components in Japanese soy sauce were: ethyl 2-methylpropanoate, ethyl 2-methylbutanoate, ethyl 3-methylbutanoate, ethyl 4-methylpentanoate, 3-(methylthio)propanal, 1-octen-3-ol, 2-methoxyphenol, 4-ethyl-2-methoxyphenol, 2-methoxy-4-vinylphenol, 2-phenylethanol, and 4-hydroxy-5-ethyl-2-methyl-3(2H)-furanone. Copyright © 2015. Published by Elsevier Ltd.
Simplified Method for Groundwater Treatment Using Dilution and Ceramic Filter
NASA Astrophysics Data System (ADS)
Musa, S.; Ariff, N. A.; Kadir, M. N. Abdul; Denan, F.
2016-07-01
Groundwater is one of the natural resources that is not susceptible to pollutants. However, increasing activities of municipal, industrial, agricultural or extreme land use activities have resulted in groundwater contamination as occured at the Research Centre for Soft Soil Malaysia (RECESS), Universiti Tun Hussein Onn Malaysia (UTHM). Thus, aims of this study is to treat groundwater by using rainwater and simple ceramic filter as a treatment agent. The treatment uses rain water dilution, ceramic filters and combined method of dilute and filtering as an alternate treatment which are simple and more practical compared to modern or chemical methods. The water went through dilution treatment processes able to get rid of 57% reduction compared to initial condition. Meanwhile, the water that passes through the filtering process successfully get rid of as much as 86% groundwater parameters where only chloride does not pass the standard. Favorable results for the combination methods of dilution and filtration methods that can succesfully eliminate 100% parameters that donot pass the standards of the Ministry of Health and the Interim National Drinking Water Quality Standard such as those found in groundwater in RECESS, UTHM especially sulfate and chloride. As a result, it allows the raw water that will use clean drinking water and safe. It also proves that the method used in this study is very effective in improving the quality of groundwater.
Measurement of plasma unbound unconjugated bilirubin.
Ahlfors, C E
2000-03-15
A method is described for measuring the unconjugated fraction of the unbound bilirubin concentration in plasma by combining the peroxidase method for determining unbound bilirubin with a diazo method for measuring conjugated and unconjugated bilirubin. The accuracy of the unbound bilirubin determination is improved by decreasing sample dilution, eliminating interference by conjugated bilirubin, monitoring changes in bilirubin concentration using diazo derivatives, and correcting for rate-limiting dissociation of bilirubin from albumin. The unbound unconjugated bilirubin concentration by the combined method in plasma from 20 jaundiced newborns was significantly greater than and poorly correlated with the unbound bilirubin determined by the existing peroxidase method (r = 0.7), possibly due to differences in sample dilution between the methods. The unbound unconjugated bilirubin was an unpredictable fraction of the unbound bilirubin in plasma samples from patients with similar total bilirubin concentrations but varying levels of conjugated bilirubin. A bilirubin-binding competitor was readily detected at a sample dilution typically used for the combined test but not at the dilution used for the existing peroxidase method. The combined method is ideally suited to measuring unbound unconjugated bilirubin in jaundiced human newborns or animal models of kernicterus. Copyright 2000 Academic Press.
Evaluation of kinetic phosphorescence analysis for the determination of uranium
DOE Office of Scientific and Technical Information (OSTI.GOV)
Croatto, P.V.; Frank, I.W.; Johnson, K.D.
In the past, New Brunswick Laboratory (NBL) has used a fluorometric method for the determination of sub-microgram quantities of uranium. In its continuing effort to upgrade and improve measurement technology, NBL has evaluated the commercially-available KPA-11 kinetic phosphorescence analyzer (Chemchek, Richland, WA). The Chemchek KPA-11 is a bench-top instrument which performs single-measurement, quench-corrected analyses for trace uranium. It incorporates patented kinetic phosphorimetry techniques to measure and analyze sample phosphorescence as a function of time. With laser excitation and time-corrected photon counting, the KPA-11 has a lower detection limit than conventional fluorometric methods. Operated with a personal computer, the state-of-the-art KPA-11more » offers extensive time resolution and phosphorescence lifetime capabilities for additional specificity. Interferences are thereby avoided while obtaining precise measurements. Routine analyses can be easily and effectively accomplished, with the accuracy and precision equivalent to the pulsed-laser fluorometric method presently performed at NBL, without the need for internal standards. Applications of kinetic phosphorimetry at NBL include the measurement of trace level uranium in retention tank, waste samples, and low-level samples. It has also been used to support other experimental activities at NBL by the measuring of nanogram amounts of uranium contamination (in blanks) in isotopic sample preparations, and the determining of elution curves of different ion exchange resins used for uranium purification. In many cases, no pretreatment of samples was necessary except to fume them with nitric acid, and then to redissolve and dilute them to an appropriate concentration with 1 M HNO{sub 3} before measurement. Concentrations were determined on a mass basis ({micro}g U/g of solution), but no density corrections were needed since all the samples (including the samples used for calibration) were in the same density matrix (1 M HNO{sub 3}). A statistical evaluation of the determination of uranium using kinetic phosphorimetry is described in this report, along with a discussion of the method, and an evaluation of the use of plastic versus quartz cuvettes. Measurement with a precision of {+-} 3--4% relative standard deviation (RSD) and an accuracy of better than {+-} 2% relative difference (RD) are obtained in the 0.0006 to 5 {micro}g U/g-solution range. The instrument detection limit is 0.04 ppb (4 x 10{sup {minus}5} {micro}g U/g solution) using quartz cells, and 0.11 ppb (11 x 10{sup {minus}5} {micro}g U/g solution) using disposable methacrylate cuvettes.« less
New methods allowing the detection of protein aggregates
Demeule, Barthélemy; Palais, Caroline; Machaidze, Gia; Gurny, Robert
2009-01-01
Aggregation compromises the safety and efficacy of therapeutic proteins. According to the manufacturer, the therapeutic immunoglobulin trastuzumab (Herceptin®) should be diluted in 0.9% sodium chloride before administration. Dilution in 5% dextrose solutions is prohibited. The reason for the interdiction is not mentioned in the Food and Drug Administration (FDA) documentation, but the European Medicines Agency (EMEA) Summary of Product Characteristics states that dilution of trastuzumab in dextrose solutions results in protein aggregation. In this paper, asymmetrical flow field-flow fractionation (FFF), fluorescence spectroscopy, fluorescence microscopy and transmission electron microscopy (TEM) have been used to characterize trastuzumab samples diluted in 0.9% sodium chloride, a stable infusion solution, as well as in 5% dextrose (a solution prone to aggregation). When trastuzumab samples were injected in the FFF channel using a standard separation method, no difference could be seen between trastuzumab diluted in sodium chloride and trastuzumab diluted in dextrose. However, during FFF measurements made with appropriate protocols, aggregates were detected in 5% dextrose. The parameters enabling the detection of reversible trastuzumab aggregates are described. Aggregates could also be documented by fluorescence microscopy and TEM. Fluorescence spectroscopy data were indicative of conformational changes consistent with increased aggregation and adsorption to surfaces. The analytical methods presented in this study were able to detect and characterize trastuzumab aggregates. PMID:20061815
Zhao, Fei; Dai, Jiang-Kun; Liu, Dan; Wang, Shi-Jun; Wang, Jun-Ru
2016-03-21
As part of our continuing research on canthin-6-one antimicrobial agents, a new series of ester derivatives of 10-hydroxycanthin-6-one were synthesized using a simple and effective synthetic route. The structure of each compound was characterized by NMR, ESI-MS, FT-IR, UV, and elemental analysis. The antimicrobial activity of these compounds against three phytopathogenic fungi (Alternaria solani, Fusarium graminearum, and Fusarium solani) and four bacteria (Bacillus cereus, Bacillus subtilis, Ralstonia solanacearum, and Pseudomonas syringae) were evaluated using the mycelium linear growth rate method and micro-broth dilution method, respectively. The structure-activity relationship is discussed. Of the tested compounds, 4 and 7s displayed significant antifungal activity against F. graminearum, with inhibition rates of 100% at a concentration of 50 μg/mL. Compounds 5, 7s, and 7t showed the best inhibitory activity against all the tested bacteria, with minimum inhibitory concentrations (MICs) between 3.91 and 31.25 μg/mL. Thus, 7s emerged as a promising lead compound for the development of novel canthine-6-one antimicrobial agents.
Benbelaïd, Fethi; Khadir, Abdelmounaïm; Abdoune, Mohamed Amine; Bendahou, Mourad; Muselli, Alain; Costa, Jean
2014-01-01
Objective To evaluate some essential oils in treatment of intractable oral infections, principally caused by biofilm of multidrug-resistant Enterococcus faecalis (E. faecalis), such as persistent endodontic infections in which their treatment exhibits a real challenge for dentists. Methods Ten chemically analyzed essential oils by gas chromatography-mass spectrometry were evaluated for antimicrobial activity against sensitive and resistant clinical strains of E. faecalis in both planktonic and biofilm state using two methods, disk diffusion and broth micro-dilution. Results Studied essential oils showed a good antimicrobial activity and high ability in E. faecalis biofilm eradication, whether for sensitive or multidrug-resistant strains, especially those of Origanum glandulosum and Thymbra capitata with interesting minimum inhibitory concentration, biofilm inhibitory concentration, and biofilm eradication concentration values which doesn't exceed 0.063%, 0.75%, and 1.5%, respectively. Conclusions Findings of this study indicate that essential oils extracted from aromatic plants can be used in treatment of intractable oral infections, especially caused by biofilm of multidrug-resistant E. faecalis. PMID:25182948
Nayak, Mahadeva; Nagarajan, A; Majeed, Muhammed; Nagabhushanam, Kalyanam; Choudhury, Ambar K
2017-08-18
This study is aimed to isolate the phytoactives from the stem bark of Artocarpus hirsutus and evaluate their in vitro anti-acne activity. The ethanolic stem bark extract of A. hirsutus provided two major phytoactive constituents: (i) pyranocycloartobiloxanthone A, (1) and (ii) Artonine E, (2) whose structures were determined by NMR and MS spectroscopic analysis. The present study is the first to report compound 1 as a mixture of two anomers (α and β), approximately 70:30 ratio. Both compounds 1 and 2 were isolated for the first time from this plant. In vitro anti-acne activity of compounds 1 and 2 were evaluated by agar well diffusion method and the minimum inhibition was determined by broth micro dilution method. The result of anti-microbial activity (MIC = 2.0 μg/mL each) is comparable to antibiotic, Clindamycin (MIC = 0.03 μg/mL) and clearly demonstrate their potential as anti-acne agents.
Chang, Chia-Kai; Wu, Chih-Che; Wang, Yi-Sheng; Chang, Huan-Cheng
2008-05-15
Despite recent advances in phosphopeptide research, detection and characterization of multiply phosphorylated peptides have been a challenge. This work presents a new strategy that not only can effectively extract phosphorylated peptides from complex samples but also can selectively enrich multiphosphorylated peptides for direct matrix-assisted laser desorption/ionization time-of-flight mass spectrometric analysis. Polyarginine-coated diamond nanoparticles are the solid-phase extraction supports used for this purpose. The supports show an exceptionally high affinity for multiphosphorylated peptides due to multiple arginine-phosphate interactions. The efficacy of this method was demonstrated by analyzing a small volume (50 microL) of tryptic digests of proteins such as beta-casein, alpha-casein, and nonfat milk at a concentration as low as 1 x 10 (-9) M. The concentration is markedly lower than that can be achieved by using other currently available technologies. We quantified the enhanced selectivity and detection sensitivity of the method using mixtures composed of mono- and tetraphosphorylated peptide standards. This new affinity-based protocol is expected to find useful applications in characterizing multiple phosphorylation sites on proteins of interest in complex and dilute analytes.
The effect of clary sage oil on staphylococci responsible for wound infections
Głowacka, Anna; Poznańska-Kurowska, Katarzyna; Kaszuba, Andrzej; Urbaniak, Anna; Kowalczyk, Edward
2015-01-01
Introduction The spreading of bacterial antibiotic resistance among clinical strains of pathogenic bacteria has made investigators to search for other active antibacterial agents which could provide a valuable complement to the existing therapies. Aim To determine the antibacterial activity of clary sage oil (Salvia sclarea L.) against Staphylococcus clinical strains which were isolated from patients with wound infections. Material and methods A comprehensive evaluation of Staphylococcus clinical strain resistance to antibiotics was performed. The constituents of clary sage oil were assayed by GC-FID-MS analysis. The minimal inhibitory concentration (MIC) of the tested essential oil against staphylococci by the micro-dilution broth method was determined. Results The clary sage oil was active against Staphylococcus aureus, S. epidermidis and S. xylosus with MIC values ranging from 3.75 to 7.00 µl/ml. Conclusions The results of the in vitro tests encourage to use formulations containing sage oil as the active natural antimicrobial agent. Because of its antimicrobial properties clary sage oil may be applied to treat wounds and skin infections. PMID:25821423
Khani, Rouhollah; Rostami, Zeinab; Bagherzade, Ghodsieh; Khojeh, Vahid
2018-03-01
In this study, for the monitoring and quantification of p-coumaric acid (p-CA) in vinegar, carrot juice, and seed extract from the plant species Silybum marianum (L.) Gaertn, an efficient and low-cost analytical method has been applied. For this purpose, a dispersive liquid-liquid microextraction (DLLME) method, followed by UV-Vis spectrophotometric detection, was used. To form a cloudy solution, a binary mixture containing ethanol as a disperser solvent and chloroform as an extraction solvent was rapidly injected by syringe into a sample solution containing p-CA. After centrifugation, dilution of the obtained organic phase was done with the proper amount of ethanol, and the phase was transferred into a micro cell for subsequent measurement. Some effective parameters for the DLLME method, such as the volume of disperser solvent and extraction solvent, pH, and salt concentration were inspected by a 24 full factorial central composite design using design Export Software. Under the optimized conditions, linearity was between 10 and 150 ng/mL, and the LOD was 2.3 ng/mL. The results of the proposed method were similar to the obtained results using a GC with flame-ionization detection method.
2014-01-01
Background The indocyanine green dilution method is one of the methods available to estimate plasma volume, although some researchers have questioned the accuracy of this method. Methods We developed a new, physiologically based mathematical model of indocyanine green kinetics that more accurately represents indocyanine green kinetics during the first few minutes postinjection than what is assumed when using the traditional mono-exponential back-extrapolation method. The mathematical model is used to develop an optimal back-extrapolation method for estimating plasma volume based on simulated indocyanine green kinetics obtained from the physiological model. Results Results from a clinical study using the indocyanine green dilution method in 36 subjects with type 2 diabetes indicate that the estimated plasma volumes are considerably lower when using the traditional back-extrapolation method than when using the proposed back-extrapolation method (mean (standard deviation) plasma volume = 26.8 (5.4) mL/kg for the traditional method vs 35.1 (7.0) mL/kg for the proposed method). The results obtained using the proposed method are more consistent with previously reported plasma volume values. Conclusions Based on the more physiological representation of indocyanine green kinetics and greater consistency with previously reported plasma volume values, the new back-extrapolation method is proposed for use when estimating plasma volume using the indocyanine green dilution method. PMID:25052018
Kumarasamy, Barani; Manipal, Sunayana; Duraisamy, Prabu; Ahmed, Adil; Mohanaganesh, Sp; Jeevika, C
2014-11-01
Use of alternative medicine to control oral streptococci is a new topic worthy of further investigation. This study aimed to elucidate the dose-dependent anti-bacterial activity of crude aqueous extract of ripe Morinda citrifolia L. (Family: Rubiaceae) fruits against oral streptococci i.e. Streptococcus mutans and Streptococcus mitis, that cause dental caries in humans. Fresh ripe M. citrifolia fruits (750g) were ground in an electronic blender with sterile water (500ml). The crude aqueous extract was lyophilized to yield a brown colored powder. Various concentrations (1000-100μg/ ml) of the extract were tested for its antibacterial activity (Kirby and Bauer method) against whole cells of S. mutans and S. mitis. Minimum Inhibitory Concentration (MIC) was determined by micro-dilution method, using serially diluted (2 folds) fruit extract, according to the National Committee for Clinical Laboratory Standards (NCCLS). Crude aqueous extract (1000μg/ ml) of ripe M. citrifolia fruits effectively inhibited the growth of S. mutans (19±0.5 mm) and S. mitis (18.6±0.3 mm) compared to the streptomycin control (21.6±0.3 mm). The growth inhibition was clearly evident with "nil" bacteriostasis, even after 48 hours of incubation at 37°C. The MIC of the extract for S. mutans and S. mitis was 125 μg and 62.5 μg, respectively. Our results suggest that phytochemicals naturally synthesized by M. citrifolia have an inhibitory effect on oral streptococci. Furthermore, purification and molecular characterization of the "bioactive principle" would enable us to formulate a sustainable oral hygiene product.
Fiser, P S; Fairfull, R W
1989-02-01
Ram semen, collected by artificial vagina, was diluted and processed for long-term storage as described by P. S. Fiser, L. Ainsworth, and R. W. Fairfull (Canad. J. Anim. Sci. 62, 425-428, 1982). The concentration of the cryoprotectant, glycerol, was adjusted to 4% in the diluted semen prior to freezing by a one-step addition at 30 degrees C (Method 1), by cooling the semen to 5 degrees C and addition of the glycerol gradually over 30 min (Method 2), by one-step addition of glycerol prior to equilibration for 2 hr (Method 3), or by cooling to 5 degrees C, followed by a holding period of 2 hr at 5 degrees C, and the one-step addition of glycerol just prior to freezing (Method 4). After thawing, the glycerol concentration of the semen was reduced by stepwise dilution from 4 to 0.4% over 15 or 30 min or by a one-step ten-fold dilution. The average post-thaw percentage of motile spermatozoa was significantly lower after addition of glycerol by Method 1 (39.9%) than when the glycerol was added by the other three methods (range, 44.0-46.4% averaged over the glycerol dilution). The average post-thaw percentage of intact acrosomes (61.2%), highest in semen in which the glycerol was added by Method 2, was not significantly different from those in which glycerol was added to semen by Methods 3 and 4, but it was significantly higher than that found in semen in which the glycerol was added by Method 1 (54.4%). However, when averaged over the method of glycerolation, the post-thaw percentage of motile spermatozoa (range, 43.7-44.2%) and the percentage of intact acrosomes (range, 56.8-59.5%) did not differ significantly in semen subjected to gradual decrease in glycerol concentration and diluent osmolality (over 15 and 30 min) or by a one-step, 10-fold dilution. These data indicate that post-thaw survival of spermatozoa can be influenced by the way in which glycerol is added prior to freezing. However, post-thaw spermatozoa motility and acrosomal integrity can be maintained even after a rapid decrease in glycerol concentration such as that which accompanies insemination or dilution of semen for assessment of motility.
Evaluation of antimicrobial activity and bronchodialator effect of a polyherbal drug-Shrishadi.
Kajaria, Divya Kumari; Gangwar, Mayank; Kumar, Dharmendra; Kumar Sharma, Amit; Tilak, Ragini; Nath, Gopal; Tripathi, Yamini Bhusan; Tripathi, J S; Tiwari, S K
2012-11-01
To investigate antimicrobial and bronchodialator effect of hydroalcholic extract of polyherbal drug Shirishadi containing Shirisha (Albezzia lebbeck), Nagarmotha (Cyprus rotandus) & Kantakari (Solanum xanthocarpum). Antimicrobial activity was evaluated by disc diffusion method and MIC, MBC, MFC were calculated by micro dilution method. Hydroalcholic extract of this preparation was investigated for its phytochemical analysis, phenol and flavonoid were determined by spectrophotometric method and in vivo bronchodilator effect was analysed by convulsion time. The phytochemical tests revealed presence of alkaloids, anthraquinones, carbohydrates, flavonoids, saponins and tannins. The antimicrobial result showed the MIC of 6.25 mg/mL against Staphylococcus aureus and 12.5 mg/mL for Escherichia coli and 12.5 mg/mL against remaining bacteria tested, with strong antifungal activity. The maximum inhibition zone is found against Pseudomonas aeruginosa with MIC 16 mg/mL. Drug showed significant bronchodilator effect with 27.86% & 36.13% increase in preconvulsion time of guinea pigs pretreated with 100 & 200 mg/kg body weight of extract. The study reveals that the extracts possess antibacterial activity and antifungal activity in a dose dependent manner. This antimicrobial property may be due to presence of several saponins, further studies are highly needed for the drug development.
Kwok, Wai Him; Choi, Timmy L S; Kwok, Karen Y; Chan, George H M; Wong, Jenny K Y; Wan, Terence S M
2016-06-17
The high sensitivity of ultra high performance liquid chromatography coupled with high resolution mass spectrometry (UHPLC-HRMS) allows the identification of many prohibited substances without pre-concentration, leading to the development of simple and fast 'dilute-and-shoot' methods for doping control for human and equine sports. While the detection of polar drugs in plasma and urine is difficult using liquid-liquid or solid-phase extraction as these substances are poorly extracted, the 'dilute-and-shoot' approach is plausible. This paper describes a 'dilute-and-shoot' UHPLC-HRMS screening method to detect 46 polar drugs in equine urine and plasma, including some angiotensin-converting enzyme (ACE) inhibitors, sympathomimetics, anti-epileptics, hemostatics, the new doping agent 5-aminoimidazole-4-carboxamide-1-β-d-ribofuranoside (AICAR), as well as two threshold substances, namely dimethyl sulfoxide and theobromine. For plasma, the sample (200μL) was protein precipitated using trichloroacetic acid, and the resulting supernatant was diluted using Buffer A with an overall dilution factor of 3. For urine, the sample (20μL) was simply diluted 50-fold with Buffer A. The diluted plasma or urine sample was then analysed using a UHPLC-HRMS system in full-scan ESI mode. The assay was validated for qualitative identification purpose. This straightforward and reliable approach carried out in combination with other screening procedures has increased the efficiency of doping control analysis in the laboratory. Moreover, since the UHPLC-HRMS data were acquired in full-scan mode, the method could theoretically accommodate an unlimited number of existing and new doping agents, and would allow a retrospectively search for drugs that have not been targeted at the time of analysis. Copyright © 2016 Elsevier B.V. All rights reserved.
USDA-ARS?s Scientific Manuscript database
A method is demonstrated for analysis of vitamin D-fortified dietary supplements that eliminates virtually all chemical pretreatment prior to analysis, and is referred to as a ‘dilute and shoot’ method. Three mass spectrometers, in parallel, plus a UV detector, an evaporative light scattering detec...
Apparatuses and methods for deoxygenating biomass-derived pyrolysis oil
Kalnes, Tom N.
2015-12-29
Apparatuses and methods for deoxygenating a biomass-derived pyrolysis oil are provided herein. In one example, the method comprises of dividing a feedstock stream into first and second feedstock portions. The feedstock stream comprises the biomass-derived pyrolysis oil and has a temperature of about 60.degree. C. or less. The first feedstock portion is combined with a heated organic liquid stream to form a first heated diluted pyoil feed stream. The first heated diluted pyoil feed stream is contacted with a first deoxygenating catalyst in the presence of hydrogen to form an intermediate low-oxygen pyoil effluent. The second feedstock portion is combined with the intermediate low-oxygen pyoil effluent to form a second heated diluted pyoil feed stream. The second heated diluted pyoil feed stream is contacted with a second deoxygenating catalyst in the presence of hydrogen to form additional low-oxygen pyoil effluent.
Alagandula, Ravali; Zhou, Xiang; Guo, Baochuan
2017-01-15
Liquid chromatography/tandem mass spectrometry (LC/MS/MS) is the gold standard of urine drug testing. However, current LC-based methods are time consuming, limiting the throughput of MS-based testing and increasing the cost. This is particularly problematic for quantification of drugs such as phenobarbital, which is often analyzed in a separate run because they must be negatively ionized. This study examined the feasibility of using a dilute-and-shoot flow-injection method without LC separation to quantify drugs with phenobarbital as a model system. Briefly, a urine sample containing phenobarbital was first diluted by 10 times, followed by flow injection of the diluted sample to mass spectrometer. Quantification and detection of phenobarbital were achieved by an electrospray negative ionization MS/MS system operated in the multiple reaction monitoring (MRM) mode with the stable-isotope-labeled drug as internal standard. The dilute-and-shoot flow-injection method developed was linear with a dynamic range of 50-2000 ng/mL of phenobarbital and correlation coefficient > 0.9996. The coefficients of variation and relative errors for intra- and inter-assays at four quality control (QC) levels (50, 125, 445 and 1600 ng/mL) were 3.0% and 5.0%, respectively. The total run time to quantify one sample was 2 min, and the sensitivity and specificity of the method did not deteriorate even after 1200 consecutive injections. Our method can accurately and robustly quantify phenobarbital in urine without LC separation. Because of its 2 min run time, the method can process 720 samples per day. This feasibility study shows that the dilute-and-shoot flow-injection method can be a general way for fast analysis of drugs in urine. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Garbarino, John R.; Taylor, Howard E.
1987-01-01
Inductively coupled plasma mass spectrometry is employed in the determination of Ni, Cu, Sr, Cd, Ba, Ti, and Pb in nonsaline, natural water samples by stable isotope dilution analysis. Hydrologic samples were directly analyzed without any unusual pretreatment. Interference effects related to overlapping isobars, formation of metal oxide and multiply charged ions, and matrix composition were identified and suitable methods of correction evaluated. A comparability study snowed that single-element isotope dilution analysis was only marginally better than sequential multielement isotope dilution analysis. Accuracy and precision of the single-element method were determined on the basis of results obtained for standard reference materials. The instrumental technique was shown to be ideally suited for programs associated with certification of standard reference materials.
Methods for Measuring Lung Volumes: Is There a Better One?
Tantucci, Claudio; Bottone, Damiano; Borghesi, Andrea; Guerini, Michele; Quadri, Federico; Pini, Laura
2016-01-01
Accurate measurement of lung volumes is of paramount importance to establish the presence of ventilatory defects and give insights for diagnostic and/or therapeutic purposes. It was the aim of this study to measure lung volumes in subjects with respiratory disorders and in normal controls by 3 different techniques (plethysmographic, dilutional and radiographic methods), in an attempt to clarify the role of each of them in performing such a task, without any presumptive 'a priori' superiority of one method above others. Patients andMethods: In different groups of subjects with obstructive and restrictive ventilatory defects and in a normal control group, total lung capacity, functional residual capacity (FRC) and residual volume were measured by body plethysmography, multi-breath helium (He) dilution and radiographic CT scan method with spirometric gating. The 3 methods gave comparable results in normal subjects and in patients with a restrictive defect. In patients with an obstructive defect, CT scan and plethysmography showed similar lung volumes, while on average significantly lower lung volumes were obtained with the He dilution technique. Taking into account that the He dilution technique does primarily measure FRC during tidal breathing, our data suggest that in some patients with an obstructive defect, a number of small airways can be functionally closed at end-expiratory lung volume, preventing He to reach the lung regions subserved by these airways. In all circumstances, both CT scan with spirometric gating and plethysmographic methods provide similar values of lung volumes. In contrast, the He dilution method can measure lower lung volumes in some patients with chronic airflow obstruction. © 2016 S. Karger AG, Basel.
Quantitative and Qualitative Study of Intestinal Flora in Neonates
Sharma, Nidhi; Chaudhry, Rama; Panigrahi, Pinaki
2012-01-01
Background: In the neonatal period the developing intestinal barrier function provides a sub-optimal mucosal defense against infection. Establishment of the normal commensal micro-flora plays a vital role in this process. Aims: To determine aerobic and anaerobic bacteria by quantitative and qualitative methods from faecal samples of neonates. Settings and Design: A prospective study was carried out in two groups in a tertiary care hospital, Group A-comprised preterm infant and in group B-full term infants. Materials and Methods: Sixty two preterm infants with the weight < 1500 gm and gestation age < 34 weeks and twenty nine full term infants with 4 weeks of age were included. Quantitation of bacterial load was done by ten-fold serial dilutions on respective media. Statistical Analysis: The data were analyzed by using EPIINFO-Ver 6.04. Results and Conclusions: The predominant aerobic bacterium was Klebsiella pneumoniae. In pre term infants aerobic bacteria were colonized with an average of 2.1 and anaerobic bacteria 0.1. Quantitation showed faecal bacterial colony count ranging from 104-1013 CFU/gms. Gram negative and gram positive bacteria increased gradually over an interval of 2 to 3 weeks. Mean log CFU of gram negative bacteria and gram positive bacteria were statistically insignificant from day 3 to day 14 (P > 0.05). On day 21 there was a significant change in colonization of both bacterial sp (P < 0.05). Potential pathogenic aerobic bacteria dominate the intestinal flora of premature babies nursed in neonatal unit. There is a need to investigate interventions to offset this imbalance in gut micro-ecology of premature babies. PMID:23326075
Plianwong, Samarwadee; Sripattanaporn, Areerut; Waewsa-nga, Kwanrutai; Buacheen, Parin; Opanasopit, Praneet; Ngawhirunpat, Tanasait; Rojanarata, Theerasak
2012-08-30
A fast, facile, and economical assay for basic nitrogenous drugs has been developed based on the mini-scale extraction of the drug-dye ion pair complex combined with the use of safe-for-analyst and eco-friendlier organic extractant and drop-based micro-spectrophotometry. Instead of using large volume devices, the extraction was simply carried out in typical 1.5 mL microcentrifuge tubes along with the use of micropipettes for accurate transfer of liquids, vortex mixer for efficient partitioning of solutes and benchtop centrifuge for rapid phase separation. In the last step, back-extraction was performed by using the microvolume of acidic solution in order to concentrate the colored species into a confined aqueous microdrop and to keep the analyst away from unwanted contact and inhalation of organic solvents during the quantitation step which was achieved by using cuvetteless UV-vis micro-spectrophotometry without any prior dilutions. Using chlorpheniramine maleate as a representative analyte and n-butyl acetate as a less toxic and non-ozone depleting extractant, the miniaturized method was less laborious and much faster. It was accurate, precise and insensitive to the interferences from common excipients. Notably, it gave the assay results of drug in tablets and oral solution comparable to the large-scale pharmacopeial method while the consumption of organic solvents and the release of wastes were lowered by 200-400 folds. Copyright © 2012 Elsevier B.V. All rights reserved.
Jugnia, Louis-B; Sime-Ngando, Télesphore; Gilbert, Daniel
2006-10-01
The growth rate and losses of bacterioplankton in the epilimnion of an oligo-mesotrophic reservoir were simultaneously estimated using three different methods for each process. Bacterial production was determined by means of the tritiated thymidine incorporation method, the dialysis bag method and the dilution method, while bacterial mortality was assessed with the dilution method, the disappearance of thymidine-labeled natural cells and ingestion of fluorescent bacterial tracers by heterotrophic flagellates. The different methods used to estimate bacterial growth rates yielded similar results. On the other hand, the mortality rates obtained with the dilution method were significantly lower than those obtained with the use of thymidine-labeled natural cells. The bacterial ingestion rate by flagellates accounted on average for 39% of total bacterial mortality estimated by the dilution method, but this value fell to 5% when the total mortality was measured by the thymidine-labeling method. Bacterial abundance and production varied in opposite phase to flagellate abundance and the various bacterial mortality rates. All this points to the critical importance of methodological aspects in the elaboration of quantitative models of matter and energy flows over the time through microbial trophic networks in aquatic systems, and highlights the role of bacterioplankton as a source of carbon for higher trophic levels in the studied system.
Micro-scale extensional rheometry using hyperbolic converging/diverging channels and jet breakup
Keshavarz, Bavand
2016-01-01
Understanding the elongational rheology of dilute polymer solutions plays an important role in many biological and industrial applications ranging from microfluidic lab-on-a-chip diagnostics to phenomena such as fuel atomization and combustion. Making quantitative measurements of the extensional viscosity for dilute viscoelastic fluids is a long-standing challenge and it motivates developments in microfluidic fabrication techniques and high speed/strobe imaging of millifluidic capillary phenomena in order to develop new classes of instruments. In this paper, we study the elongational rheology of a family of dilute polymeric solutions in two devices: first, steady pressure-driven flow through a hyperbolic microfluidic contraction/expansion and, second, the capillary driven breakup of a thin filament formed from a small diameter jet (Dj∼O(100 μm)). The small length scale of the device allows very large deformation rates to be achieved. Our results show that in certain limits of low viscosity and elasticity, jet breakup studies offer significant advantages over the hyperbolic channel measurements despite the more complex implementation. Using our results, together with scaling estimates of the competing viscous, elastic, inertial and capillary timescales that control the dynamics, we construct a dimensionless map or nomogram summarizing the operating space for each instrument. PMID:27375824
Schulze, M; Ammon, C; Schaefer, J; Luther, A-M; Jung, M; Waberski, D
2017-07-01
The dilution of ejaculates is a fundamental step for the production of liquid-preserved boar semen. For a long time, it has been recommended to add the extender to the ejaculate. The aim of the present study was to first compare the effect of the position ('center' vs. 'wall') where the extender is added to the semen-mixing cylinder (height 32.5cm; diameter 12.7cm) using an automatic dispenser (n=11). In experiment 2 (n=30), we analyzed the two main dilution methods (extender to the semen ('control') vs. 'reverse'). Experiment 3 was carried out to study the dilution effect on kinematics. In Experiments 1 and 2, the sperm distribution 10min after the dilution and the sperm quality parameters during long-term storage (d1, d3, d5, and d7) were evaluated. In Experiment 3, sperm quality was assessed during short-term storage at 0, 10, 20, 30 and 60min after semen dilution ('control' vs. 'reverse'; n=6). There were no significant differences (P>0.05) between the treatments in the specific response to bicarbonate, mitochondrial activity, membrane status, thermo-resistance or sperm motility immediately after dilution or long-term storage. The sperm distribution was significantly (P=0.029) affected by the dilution method in Experiment 2. In summary, treatment with the extender first, which is used by only a few European boar studs, leads to comparable results in sperm quality during storage and better results in sperm distribution after dilution. This procedure is also less time consuming, less foam formation occurs during the semen dilution and the procedure is more hygienic. Copyright © 2017 Elsevier B.V. All rights reserved.
Morán-Marroquín, G A; Córdova, J; Valle-Rodríguez, J O; Estarrón-Espinosa, M; Díaz-Montaño, D M
2011-11-15
Knowledge of physiological behavior of indigenous tequila yeast used in fermentation process is still limited. Yeasts have significant impact on the productivity fermentation process as well as the sensorial characteristics of the alcoholic beverage. For these reasons a better knowledge of the physiological and metabolic features of these yeasts is required. The effects of dilution rate, nitrogen and phosphorus source addition and micro-aeration on growth, fermentation and synthesis of volatile compounds of two native Saccharomyces cerevisiae strains, cultured in continuous fed with Agave tequilana juice were studied. For S1 and S2 strains, maximal concentrations of biomass, ethanol, consumed sugars, alcohols and esters were obtained at 0.04 h⁻¹. Those concentrations quickly decreased as D increased. For S. cerevisiae S1 cultures (at D=0.08 h⁻¹) supplemented with ammonium phosphate (AP) from 1 to 4 g/L, concentrations of residual sugars decreased from 29.42 to 17.60 g/L and ethanol increased from 29.63 to 40.08 g/L, respectively. The S1 culture supplemented with AP was then micro-aerated from 0 to 0.02 vvm, improving all the kinetics parameters: biomass, ethanol and glycerol concentrations increased from 5.66, 40.08 and 3.11 g/L to 8.04, 45.91 and 4.88 g/L; residual sugars decreased from 17.67 g/L to 4.48 g/L; and rates of productions of biomass and ethanol, and consumption of sugars increased from 0.45, 3.21 and 7.33 g/L·h to 0.64, 3.67 and 8.38 g/L·h, respectively. Concentrations of volatile compounds were also influenced by the micro-aeration rate. Ester and alcohol concentrations were higher, in none aerated and in aerated cultures respectively. Copyright © 2011. Published by Elsevier B.V.
Determination of the concentration of a Bryonia Dioica tincture by Raman spectroscopy
NASA Astrophysics Data System (ADS)
Milea, Irimie; Culea, E.; Iliescu, T.; Milea, Janetta
1995-03-01
It was established a method based on Raman spectroscopy in order to control the content and concentration of homeopathic dilutions. Dilutions of a tincture of Bryonia Dioica in ethanol were prepared and investigated by Raman spectroscopy. The Raman line at 881 cm-1 was found to depend linearly versus the concentration of Bryonia Dioica. This permits to obtain a calibration curve that may be used to determine the concentration of Bryonia Dioica in ethanol. The method may be extended to determine the concentration of various homeopathic dilutions.
Stephens, J C; Rogers, J; Ruano, G
1990-01-01
In a recent paper we have shown that DNA haplotypes of multiply heterozygous individuals can be resolved directly by polymerase-chain-reaction (PCR) amplification of a single molecule of genomic template. Our method (the single-molecule-dilution [SMD] method) relies on the stochastic separation of maternal and paternal alleles at high dilution. The stochasticity of separation and the potential for DNA shearing (which could separate the loci of interest) are two factors that can compromise the results of the experiment. This paper explores the consequences of these two factors and shows that the SMD method can be expected to work very reliably even in the presence of a moderate amount of DNA shearing. PMID:2339707
Fabrication of super-hydrophobic duo-structures
NASA Astrophysics Data System (ADS)
Zhang, X. Y.; Zhang, F.; Jiang, Y. J.; Wang, Y. Y.; Shi, Z. W.; Peng, C. S.
2015-04-01
Recently, super-hydrophobicity has attracted increasing attention due to its huge potential in the practical applications. In this paper, we have presented a duo-structure of the combination of micro-dot-matrix and nano-candle-soot. Polydimethylsiloxane (PDMS) was used as a combination layer between the dot-matrix and the soot particles. Firstly, a period of 9-μm dot-matrix was easily fabricated on the K9 glass using the most simple and mature photolithography process. Secondly, the dot-matrix surface was coated by a thin film of PDMS (elastomer: hardener=10:1) which was diluted by methylbenzene at the volume ratio of 1:8. Thirdly, we held the PDMS modified surface over a candle flame to deposit a soot layer and followed by a gentle water-risen to remove the non-adhered particles. At last, the samples were baked at 85°C for 2 hours and then the duo-structure surface with both micro-size dot-matrix and nano-size soot particles was obtained. The SEM indicated this novel surface morphology was quite like a lotus leaf of the well-know micro-nano-binary structures. As a result, the contact angle meter demonstrated such surface exhibited a perfect super-hydrophobicity with water contact angle of 153° and sliding angle of 3°. Besides, just listed as above, the fabrication process for our structure was quite more easy, smart and low-cost compared with the other production technique for super-hydrophobic surfaces such as the phase separation method, electrochemical deposition and chemical vapor deposition etc. Hence, this super-hydrophobic duo-structure reported in this letter was a great promising candidate for a wide and rapid commercialization in the future.
Chemical Disposal for a High School Chemistry Laboratory
ERIC Educational Resources Information Center
Mento, Mary Ann
1973-01-01
A method of disposal is suggested that is superior to the dilution method. The proceudres are based on the conversion of the wastes to less toxic or harmless forms or neutralization, so that they won't be a shock to the sewage system, and then excess dilution. (Author/DF)
Sibar, Serhat; Findikcioglu, Kemal; Zinnuroglu, Murat; Cenetoglu, Seyhan
2017-04-01
Today, botulinum toxin is commonly used for cosmetic purposes throughout the world. Despite various agents reducing the efficiency of toxin are well defined, the studies related to increasing the bioavailability are limited. The purpose of our study is to assess the effect of the preparation of toxin by diluting with platelet-poor plasma (PPP) and/or albumin instead of standard dilution (saline) on bioavailability in cosmetic-purpose botulinum toxin applications.In the study, 24 New Zealand rabbits were used. Right anterior auricular muscle was preferred for toxin injections. Subjects were divided in 4 groups and in every group; botulinum A toxin (BTxA) that was prepared by different dilution methods was injected. 2.5 U saline-diluted BTxA was injected to the subjects in group 1, 2.5 U ready-to-use rabbit albumin-diluted BTxA was injected to group 2 and 2.5 U autologous PPP-diluted BTxA was injected to group 3 and pure saline was injected to group 4.Before the injection (0th week) and in the second, sixth, and 12th weeks after the injection, visual and electroneuromyographic evaluations of the ears of the subjects were performed.In the second week, median amplitude levels in group 2 were significantly found lower than other groups.In the sixth week, median amplitude levels in group 1 were significantly found lower than other groups.In 12th week, no significant difference was found among all the groups in terms of median amplitude levels.Visual findings were also correlated with electroneuromyographic findings.It was observed that the dilution of BTxA with albumin had caused a stronger paralysis when compared to dilution with saline or PPP at the beginning (second week); however, in the following weeks (sixth week), it was seen that dilution with saline had maintained paralysis better when compared with other dilution methods.In cosmetic BTxA applications, dilution of the toxin with albumin or PPP instead of standard dilution has no positive effect on bioavailability and such modifications regarding this kind of dilution are found unsuitable. Further studies are needed to directly relate the results with clinical applications.
Randomly diluted eg orbital-ordered systems.
Tanaka, T; Matsumoto, M; Ishihara, S
2005-12-31
Dilution effects on the long-range ordered state of the doubly degenerate e(g) orbital are investigated. Quenched impurities without the orbital degree of freedom are introduced in the orbital model where the long-range order is realized by the order-from-disorder mechanism. It is shown by Monte Carlo simulations and the cluster-expansion method that a decrease in the orbital-ordering temperature by dilution is substantially larger than that in the randomly diluted spin models. Tilting of orbital pseudospins around impurities is the essence of this dilution effect. The present theory provides a new viewpoint for the recent resonant x-ray scattering experiments in KCu(1-x)Zn(x)F(3).
Dilute acid/metal salt hydrolysis of lignocellulosics
Nguyen, Quang A.; Tucker, Melvin P.
2002-01-01
A modified dilute acid method of hydrolyzing the cellulose and hemicellulose in lignocellulosic material under conditions to obtain higher overall fermentable sugar yields than is obtainable using dilute acid alone, comprising: impregnating a lignocellulosic feedstock with a mixture of an amount of aqueous solution of a dilute acid catalyst and a metal salt catalyst sufficient to provide higher overall fermentable sugar yields than is obtainable when hydrolyzing with dilute acid alone; loading the impregnated lignocellulosic feedstock into a reactor and heating for a sufficient period of time to hydrolyze substantially all of the hemicellulose and greater than 45% of the cellulose to water soluble sugars; and recovering the water soluble sugars.
Evaluation of antimicrobial activity and bronchodialator effect of a polyherbal drug-Shrishadi
Kajaria, Divya Kumari; Gangwar, Mayank; Kumar, Dharmendra; Kumar Sharma, Amit; Tilak, Ragini; Nath, Gopal; Tripathi, Yamini Bhusan; Tripathi, JS; Tiwari, SK
2012-01-01
Objective To investigate antimicrobial and bronchodialator effect of hydroalcholic extract of polyherbal drug Shirishadi containing Shirisha (Albezzia lebbeck), Nagarmotha (Cyprus rotandus) & Kantakari (Solanum xanthocarpum). Methods Antimicrobial activity was evaluated by disc diffusion method and MIC, MBC, MFC were calculated by micro dilution method. Hydroalcholic extract of this preparation was investigated for its phytochemical analysis, phenol and flavonoid were determined by spectrophotometric method and in vivo bronchodilator effect was analysed by convulsion time. Results The phytochemical tests revealed presence of alkaloids, anthraquinones, carbohydrates, flavonoids, saponins and tannins. The antimicrobial result showed the MIC of 6.25 mg/mL against Staphylococcus aureus and 12.5 mg/mL for Escherichia coli and 12.5 mg/mL against remaining bacteria tested, with strong antifungal activity. The maximum inhibition zone is found against Pseudomonas aeruginosa with MIC 16 mg/mL. Drug showed significant bronchodilator effect with 27.86% & 36.13% increase in preconvulsion time of guinea pigs pretreated with 100 & 200 mg/kg body weight of extract. Conclusions The study reveals that the extracts possess antibacterial activity and antifungal activity in a dose dependent manner. This antimicrobial property may be due to presence of several saponins, further studies are highly needed for the drug development. PMID:23569869
Lucaire, Vincent; Schwartz, Jean-Jacques; Delhomme, Olivier; Ocampo-Torres, Ruben; Millet, Maurice
2018-03-01
Monitoring the levels of aliphatic and aromatic amines (AA) in indoor air is important to protect human health because of exposure to these compounds through diet and inhalation. A sampling and analytical method using XAD-2 cartridges and gas chromatography coupled to mass spectrometry used for assessing 25 AA in different smoking and non-smoking indoor environment was developed. After sampling and delivering 1 m 3 of air (6-8 h sampling), an adsorbent was ultrasonically extracted with acetonitrile, concentrated to 1 mL and diluted in 25 mL of water (pH = 9; 5% NaCl), and then extracted for 40 min at 80 °C using a divinylbenzene/carboxen/polydimethylsiloxane (DVB/CAR/PDMS) fiber and injected in a GC/MS system. With this method, 22 of the 25 AA can be analyzed with detection limits up to five times lower than that of classic liquid injection. Benzylamine, 3-aminophenol, and 4-aminophenol were not detected with the solid-phase micro-extraction (SPME) method. It can be assumed that aminophenols required a derivatization step for their analysis by GC as these molecules were not detected regardless of the injection mode used. Graphical abstract Analysis of aromatic amines in indoor air by SPME-GC/MS.
Boulyga, Sergei F; Heilmann, Jens; Prohaska, Thomas; Heumann, Klaus G
2007-10-01
A method for the direct multi-element determination of Cl, S, Hg, Pb, Cd, U, Br, Cr, Cu, Fe, and Zn in powdered coal samples has been developed by applying inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) with laser-assisted introduction into the plasma. A sector-field ICP-MS with a mass resolution of 4,000 and a high-ablation rate laser ablation system provided significantly better sensitivity, detection limits, and accuracy compared to a conventional laser ablation system coupled with a quadrupole ICP-MS. The sensitivity ranges from about 590 cps for (35)Cl+ to more than 6 x 10(5) cps for (238)U+ for 1 microg of trace element per gram of coal sample. Detection limits vary from 450 ng g(-1) for chlorine and 18 ng g(-1) for sulfur to 9.5 pg g(-1) for mercury and 0.3 pg g(-1) for uranium. Analyses of minor and trace elements in four certified reference materials (BCR-180 Gas Coal, BCR-331 Steam Coal, SRM 1632c Trace Elements in Coal, SRM 1635 Trace Elements in Coal) yielded good agreement of usually not more than 5% deviation from the certified values and precisions of less than 10% relative standard deviation for most elements. Higher relative standard deviations were found for particular elements such as Hg and Cd caused by inhomogeneities due to associations of these elements within micro-inclusions in coal which was demonstrated for Hg in SRM 1635, SRM 1632c, and another standard reference material (SRM 2682b, Sulfur and Mercury in Coal). The developed LA-ICP-IDMS method with its simple sample pretreatment opens the possibility for accurate, fast, and highly sensitive determinations of environmentally critical contaminants in coal as well as of trace impurities in similar sample materials like graphite powder and activated charcoal on a routine basis.
Entrainment vs. Dilution in Tropical Deep Convection
NASA Astrophysics Data System (ADS)
Hannah, W.
2017-12-01
The distinction between entrainment and dilution is investigated with cloud resolving simulations of deep convection in a tropical environment. A method for estimating the rate of dilution by entrainment and detrainment is calculated for a series of bubble simulations with a range of initial radii. Entrainment generally corresponds to dilution of convection, but the two quantities are not well correlated. Core dilution by entrainment is significantly reduced by the presence of a shell of moist air around the core. Entrainment contributes significantly to the total net dilution, but detrainment and the various source/sink terms play large roles depending on the variable in question. Detrainment has a concentrating effect on average that balances out the dilution by entrainment. The experiments are also used to examine whether entrainment or dilution scale with cloud radius. The results support a weak negative relationship for dilution, but not for entrainment. The sensitivity to resolution is briefly discussed. A toy Lagrangian thermal model is used to demonstrate the importance of the cloud shell as a thermodynamic buffer to reduce the dilution of the core by entrainment. The results suggest that explicit cloud heterogeneity may be a useful consideration for future convective parameterization development.
Alcántara-Durán, Jaime; Moreno-González, David; Beneito-Cambra, Miriam; García-Reyes, Juan F
2018-05-15
In this work, a sensitive nanoflow liquid chromatography high-resolution mass spectrometry screening method has been developed for the determination of multiclass drugs of abuse and sport drugs in human urine. 81 drugs belonging to different multiclass pharmaceuticals were targeted. The method is based on the use of a nanoLC column (75 µm × 150 mm, 3 µm particle size and 100 Å pore) with the nanospray emitter tip integrated so that dead volumes are significantly minimized. Data acquisition method included both full-scan and all ion fragmentation experiments using an Orbitrap analyser (Q-Exactive) operated in the positive ionization mode. To increase laboratory throughput, a dilute-and-shoot methodology has been tested and proposed, based solely on direct urine dilution without further sample workup. Matrix effects were evaluated, showing a negligible effect for all studied compounds when a dilution 1:50 was implemented. Despite this high-dilution factor, limits of quantification were still satisfactory, with values below 5 µg L -1 in most cases, being lower than their minimum required performance limits correspond established by the World Anti-Doping Agency. Therefore, the use of the dilute-and-shoot method with the enhanced sensitivity provided by nanoflow LC setup could be useful tool for the determination of studied compounds in drug testing, thus increasing laboratory performance, because a minimum sample treatment steps are required. Copyright © 2018 Elsevier B.V. All rights reserved.
Goblick, Gregory N; Ao, Yaping; Anbarchian, Julie M; Calci, Kevin R
2017-02-15
Since 1925, dilution analysis has been used to minimize pathogenic impacts to bivalve molluscan shellfish growing areas from treated wastewater effluent in the National Shellfish Sanitation Program (NSSP). For over twenty five years, the U.S. Food and Drug Administration (FDA) has recommended a minimum of 1000:1 dilution of effluent within prohibited closure zones established around wastewater treatment plant (WWTP) discharges. During May 2010, using recent technologies, a hydrographic dye study was conducted in conjunction with a pathogen bioaccumulation study in shellfish adjacent to a WWTP discharge in Yarmouth, ME. For the first time an improved method of the super-position principle was used to determine the buildup of dye tagged sewage effluent and steady state dilution in tidal waters. Results of the improved method of dilution analysis illustrate an economical, reliable and more accurate and manageable approach for estimating the buildup and steady state pollutant conditions in coastal and estuarine waters. Published by Elsevier Ltd.
Entrainment versus Dilution in Tropical Deep Convection
Hannah, Walter M.
2017-11-01
In this paper, the distinction between entrainment and dilution is investigated with cloud-resolving simulations of deep convection in a tropical environment. A method for estimating the rate of dilution by entrainment and detrainment is presented and calculated for a series of bubble simulations with a range of initial radii. Entrainment generally corresponds to dilution of convection, but the two quantities are not well correlated. Core dilution by entrainment is significantly reduced by the presence of a shell of moist air around the core. Dilution by entrainment also increases with increasing updraft velocity but only for sufficiently strong updrafts. Entrainment contributesmore » significantly to the total net dilution, but detrainment and the various source/sink terms play large roles depending on the variable in question. Detrainment has a concentrating effect on average that balances out the dilution by entrainment. The experiments are also used to examine whether entrainment or dilution scale with cloud radius. The results support a weak negative relationship for dilution but not for entrainment. The sensitivity to resolution is briefly discussed. A toy Lagrangian thermal model is used to demonstrate the importance of the cloud shell as a thermodynamic buffer to reduce the dilution of the core by entrainment. Finally, the results suggest that explicit cloud heterogeneity may be a useful consideration for future convective parameterization development.« less
A helium-3/helium-4 dilution cryocooler for operation in zero gravity
NASA Technical Reports Server (NTRS)
Hendricks, John B.
1988-01-01
This research effort covered the development of He-3/He-4 dilution cryocooler cycles for use in zero gravity. The dilution cryocooler is currently the method of choice for producing temperatures below 0.3 Kelvin in the laboratory. However, the current dilution cryocooler depends on gravity for their operation, so some modification is required for zero gravity operation. In this effort, we have demonstrated, by analysis, that the zero gravity dilution cryocooler is feasible. We have developed a cycle that uses He-3 circulation, and an alternate cycle that uses superfluid He-4 circulation. The key elements of both cycles were demonstrated experimentally. The development of a true 'zero-gravity' dilution cryocooler is now possible, and should be undertaken in a follow-on effort.
Antimicrobial activity of topical anaesthetic preparations.
Badenoch, P R; Coster, D J
1982-01-01
Eight commercial topical anaesthetic preparations were tested for their ability to inhibit microbial growth in vitro by incubating serial dilutions with each of 4 micro-organisms. In addition corneas of mice were infected with Staphylococcus aureus, and the effect of the anaesthetics on isolation rates of bacteria was investigated. The preparations were shown to have a wide range of antimicrobial activity, correlating both with the active agents and the preservatives. We suggest that some preparations are unsuitable for use prior to collection of specimens from human corneal ulcers. PMID:6805500
Staley, Christopher; Gordon, Katrina V.; Schoen, Mary E.
2012-01-01
Before new, rapid quantitative PCR (qPCR) methods for assessment of recreational water quality and microbial source tracking (MST) can be useful in a regulatory context, an understanding of the ability of the method to detect a DNA target (marker) when the contaminant source has been diluted in environmental waters is needed. This study determined the limits of detection and quantification of the human-associated Bacteroides sp. (HF183) and human polyomavirus (HPyV) qPCR methods for sewage diluted in buffer and in five ambient, Florida water types (estuarine, marine, tannic, lake, and river). HF183 was quantifiable in sewage diluted up to 10−6 in 500-ml ambient-water samples, but HPyVs were not quantifiable in dilutions of >10−4. Specificity, which was assessed using fecal composites from dogs, birds, and cattle, was 100% for HPyVs and 81% for HF183. Quantitative microbial risk assessment (QMRA) estimated the possible norovirus levels in sewage and the human health risk at various sewage dilutions. When juxtaposed with the MST marker detection limits, the QMRA analysis revealed that HF183 was detectable when the modeled risk of gastrointestinal (GI) illness was at or below the benchmark of 10 illnesses per 1,000 exposures, but the HPyV method was generally not sensitive enough to detect potential health risks at the 0.01 threshold for frequency of illness. The tradeoff between sensitivity and specificity in the MST methods indicates that HF183 data should be interpreted judiciously, preferably in conjunction with a more host-specific marker, and that better methods of concentrating HPyVs from environmental waters are needed if this method is to be useful in a watershed management or monitoring context. PMID:22885746
RM Methods for Multiple Fare Structure Environments
2008-06-01
110 9 LIST OF FIGURES 1 INTRODUCTION Figure 1-1: Revenue Losses due to Overprotection and Dilution... overprotection or dilution. If an airline’s objective is to focus on high-yield business travelers and charge only a single high fare for the...Lost Revenue from Customer Surplus Captured Revenue Rejected Passengers Overprotection Dilution Figure 1-1: Revenue Losses due to Overprotection
Quantifying the dilution effect for models in ecological epidemiology.
Roberts, M G; Heesterbeek, J A P
2018-03-01
The dilution effect , where an increase in biodiversity results in a reduction in the prevalence of an infectious disease, has been the subject of speculation and controversy. Conversely, an amplification effect occurs when increased biodiversity is related to an increase in prevalence. We explore the conditions under which these effects arise, using multi species compartmental models that integrate ecological and epidemiological interactions. We introduce three potential metrics for quantifying dilution and amplification, one based on infection prevalence in a focal host species, one based on the size of the infected subpopulation of that species and one based on the basic reproduction number. We introduce our approach in the simplest epidemiological setting with two species, and show that the existence and strength of a dilution effect is influenced strongly by the choices made to describe the system and the metric used to gauge the effect. We show that our method can be generalized to any number of species and to more complicated ecological and epidemiological dynamics. Our method allows a rigorous analysis of ecological systems where dilution effects have been postulated, and contributes to future progress in understanding the phenomenon of dilution in the context of infectious disease dynamics and infection risk. © 2018 The Author(s).
Lin, YuPo J.; Hestekin, Jamie; Arora, Michelle; St. Martin, Edward J.
2004-09-28
An electrodeionization method for continuously producing and or separating and/or concentrating ionizable organics present in dilute concentrations in an ionic solution while controlling the pH to within one to one-half pH unit method for continuously producing and or separating and/or concentrating ionizable organics present in dilute concentrations in an ionic solution while controlling the pH to within one to one-half pH unit.
In Situ Local Fracture Flow Measurement by the Double Packer Dilution Test
NASA Astrophysics Data System (ADS)
Englert, A.; Le Borgne, T.; Bour, O.; Klepikova, M.; Lavenant, N.
2011-12-01
For prediction of flow and transport in fractured media, prior estimation of the fracture network is essential, but challenging. Recent developments in hydraulic tomography have shown promising results for understanding connectivities between boreholes. However, as the hydraulic tomographic survey is typically based on the propagation of head only, it becomes a strongly non unique problem. To reduce the non uniqueness of tomographic surveys point conditioning has been found beneficial. Just as well, measurement of local flow in a fracture can serve as point conditioning for hydraulic and tracer tomographic surveys. Nevertheless, only few measurements of local fracture flow have been performed since this type of measurements implies several important technical issues. Dilution test in a packed off interval is a possible method for measuring fracture flow (e.g. Drost et al. 1968, Novakowski et al., 2005). However, a key issue for estimating flow with dilution tests is to ensure a full mixing of the tracer in the packed interval. This is typically done by including a mixing system within the packer. The design of such system can be challenging for deep wells and small diameters. Here, we propose a method where mixing is ensured by a recirculation loop including a surface tank. This method is adapted from the design proposed by Brouyere et al. (2008), who measured dilution in open wells. Dilution is quantified by measuring the concentration in the surface barrel as function of time. Together with the measurement of the circulating flow and the water filled volume in the surface barrel, the measured tracer dilution allows for calculation of the fracture flow. Since the method can be applied using a classical double packer system, it may provide a broader application of local flow measurements in heterogeneous media. We tested the approach on the Ploemeur fractured crystalline rock site. A one meter interval at depth 80 m with a single flowing fracture was isolated with a double packer dilution system. We performed a pumping test in the adjacent well. Different flow rates were estimated from the dilution curves for the different pumping rates in the adjacent well, showing a linear response. The obtained fracture flow rates provide important information on the flow geometry and connectivity between the two wells. Future joint interpretation of flow measurements, hydraulic head and tracer test data is expected to provide detailed insights in the flow and transport processes at the Ploemeur site. Drost, W., Klotz, D., Koch, A., Moser, H., Neumaier, F., Rauert, W.: Point dilution methods of investigating ground water flow by means of radioisotopes, Water. Resour. Res., 4(1), 1968. Novakowski, K., Bickerton, G., Lapcevic, P., Voralek, J., Ross, N.: Measurements of groundwater velocity in discrete rock fractures: Jour. Cont. Hydr., 82(1-2), 2006. Brouyere, S., Batlle-Aguilar, J., Goderniaux, P., Dassargues, A.: A new tracer technique for monitoring groundwater fluxes: The Finite Volume Point Dilution Method, Jour. Cont. Hydr., 95(3-4), 121-140, 2008.
Wali, Nadia; Mirza, Irfan Ali
2016-04-01
To compare the in vitro efficacy of doripenem and imipenem against multi-drug resistant (MDR) Pseudomonas aeruginosa from various clinical specimens. Descriptive cross-sectional study. Department of Microbiology, Armed Forces Institute of Pathology, Rawalpindi, from November 2012 to November 2013. MDR Pseudomonas aeruginosa isolates from various clinical samples were included in the study. Susceptibility of Pseudomonas aeruginosa against doripenem and imipenem was performed by E-test strip and agar dilution methods. The results were interpreted as recommended by Clinical Laboratory Standard Institute (CLSI) guidelines. The maximum number of Pseudomonas aeruginosa were isolated from pure pus and pus swabs. In vitro efficacy of doripenem was found to be more effective as compared to imipenem against MDR Pseudomonas aeruginosa with both E-test strip and agar dilution methods. Overall, p-values of 0.014 and 0.037 were observed when susceptibility patterns of doripenem and imipenem were evaluated with E-test strip and agar dilution methods. In vitro efficacy of doripenem was found to be better against MDR Pseudomonas aeruginosaas compared to imipenem when tested by both E-test and agar dilution methods.
NASA Astrophysics Data System (ADS)
Schroeder, Charles
Semi-dilute polymer solutions are encountered in a wide array of applications such as advanced 3D printing technologies. Semi-dilute solutions are characterized by large fluctuations in concentration, such that hydrodynamic interactions, excluded volume interactions, and transient chain entanglements may be important, which greatly complicates analytical modeling and theoretical treatment. Despite recent progress, we still lack a complete molecular-level understanding of polymer dynamics in these systems. In this talk, I will discuss three recent projects in my group to study semi-dilute solutions that focus on single molecule studies of linear and ring polymers and a new method to measure normal stresses in microfluidic devices based on the Stokes trap. In the first effort, we use single polymer techniques to investigate the dynamics of semi-dilute unentangled and semi-dilute entangled DNA solutions in extensional flow, including polymer relaxation from high stretch, transient stretching dynamics in step-strain experiments, and steady-state stretching in flow. In the semi-dilute unentangled regime, our results show a power-law scaling of the longest polymer relaxation time that is consistent with scaling arguments based on the double cross-over regime. Upon increasing concentration, we observe a transition region in dynamics to the entangled regime. We also studied the transient and steady-state stretching dynamics in extensional flow using the Stokes trap, and our results show a decrease in transient polymer stretch and a milder coil-to-stretch transition for semi-dilute polymer solutions compared to dilute solutions, which is interpreted in the context of a critical Weissenberg number Wi at the coil-to-stretch transition. Interestingly, we observe a unique set of polymer conformations in semi-dilute unentangled solutions that are highly suggestive of transient topological entanglements in solutions that are nominally unentangled at equilibrium. Taken together, these results suggest that the transient stretching pathways in semi-dilute solution extensional flows are qualitatively different than for both dilute solutions and for semi-dilute solutions in shear flow. In a second effort, we studied the dynamics of ring polymers in background solutions of semi-dilute linear polymers. Interestingly, we observe strikingly large fluctuations in steady-state polymer extension for ring polymers in flow, which occurs due to the interplay between polymer topology and concentration leading to chain `threading' in flow. In a third effort, we developed a new microfluidic method to measure normal stress and extensional viscosity that can be loosely described as passive yet non-linear microrheology. In particular, we incorporated 3-D particle imaging velocimetry (PIV) with the Stokes trap to study extensional flow-induced particle migration in semi-dilute polymer solutions. Experimental results are analyzed using the framework of a second-order-fluid model, which allows for measurement of normal stress and extensional viscosity in semi-dilute polymer solutions, all of which is a first-of-its-kind demonstration. Microfluidic measurements of extensional viscosity are directly compared to the dripping-onto-substrate or DOS method, and good agreement is generally observed. Overall, our work aims to provide a molecular-level understanding of the role of polymer topology and concentration on bulk rheological properties by using single polymer techniques.
Kikuchi, Tatsuya; Okamura, Toshimitsu; Arai, Takuya; Obata, Takayuki; Fukushi, Kiyoshi; Irie, Toshiaki; Shiraishi, Tetsuya
2010-01-01
Background and purpose: Cholinesterase inhibitors have been widely used for the treatment of patients with dementia. Monitoring of the cholinesterase activity in the blood is used as an indicator of the effect of the cholinesterase inhibitors in the brain. The selective measurement of cholinesterase with low tissue dilution is preferred for accurate monitoring; however, the methods have not been established. Here, we investigated the effect of tissue dilution on the action of cholinesterase inhibitors using a novel radiometric method with selective substrates, N-[14C]methylpiperidin-4-yl acetate ([14C]MP4A) and (R)-N-[14C]methylpiperidin-3-yl butyrate ([14C]MP3B_R), for AChE and butyrylcholinesterase (BChE) respectively. Experimental approach: We investigated the kinetics of hydrolysis of [14C]-MP4A and [14C]-MP3B_R by cholinesterases, and evaluated the selectivity of [14C]MP4A and [14C]MP3B_R for human AChE and BChE, respectively, compared with traditional substrates. Then, IC50 values of cholinesterase inhibitors in minimally diluted and highly diluted tissues were measured with [14C]MP4A and [14C]MP3B_R. Key results: AChE and BChE activities were selectively measured as the first-order hydrolysis rates of [14C]-MP4A and [14C]MP3B_R respectively. The AChE selectivity of [14C]MP4A was an order of magnitude higher than traditional substrates used for the AChE assay. The IC50 values of specific AChE and BChE inhibitors, donepezil and ethopropazine, in 1.2-fold diluted human whole blood were much higher than those in 120-fold diluted blood. In addition, the IC50 values of donepezil in monkey brain were dramatically decreased as the tissue was diluted. Conclusions and implications: This method would effectively monitor the activity of cholinesterase inhibitors used for therapeutics, pesticides and chemical warfare agents. PMID:20401964
Sonic wave separation of invertase from a dilute solution to generated droplets.
Tanner, R D; Ko, S; Loha, V; Prokop, A
2000-01-01
It has previously been shown that a droplet fractionation process, simulated by shaking a separatory funnel containing a dilute protein solution, can generate droplets richer in protein than present in the original dilute solution. In this article, we describe an alternative method that can increase the amount of protein transferred to the droplets. The new method uses ultrasonic waves, enhanced by a bubble gas stream to create the droplets. The amount of protein in these droplets increases by about 50%. In this method, the top layer of the dilute protein solution (of the solution-air interface) becomes enriched in protein when air is bubbled into the solution. This concentrating procedure is called bubble fractionation. Once the protein has passed through the initial buildup, this enriched protein layer is transferred into droplets with the aid of a vacuum above the solution at the same time that ultrasonic waves are introduced. The droplets are then carried over to a condenser and coalesced. We found that this new method provides an easier way to remove the protein-enriched top layer of the dilute solution and generates more droplets within a shorter period than the separatory funnel droplet generation method. The added air creates the bubbles and carries the droplets, and the vacuum helps remove the effluent airstream from the condenser. The maximum partition coefficient, the ratio of the protein concentration in the droplets to that in the residual solution (approx 8.5), occurred at pH 5.0.
Rapid surface colony counts determination with three new miniaturised techniques.
Malik, K A
1977-01-01
Three different miniaturised methods for the rapid surface viable counting are described. The methods were tried in parallel to seven different existing methods (Table 1) for viable counts and were found to be easier, quicker and insome cases more accurate. The techniques require about 10% of the material and time needed for conventional spread-plates method and the results were in no way inferior to that (Table 1 and 2). Mini agar discs were cut aseptically with an especially designed stainless steel agar disc cutter (25 mm internal and 28 mm external diameter, Fig. 1b) or with a test tube of similar diameter. The area of the resulted mini-agar-disc of 25 mm diameter was kept such (about 1/10th of the normal plate) that the ratio of the colony-bearing area to the inoculm remained the same as on big plates in spread-plate-method (Table 2). In normal Petri dishes (about 90 mm diameter) up to seven mini agar discs were possible to cut. Each small agar disc was seperated from the other mini-disc by a distance of at least 6 mm (Fig. 1a). The empty place around the disc was still enlarged during over drying of the plates and during incubation. This created complete isolation from the neighbouring disc. For micro-determination of surface viable counts 10 micronl from each dilution was delivered on a well-dired mini-disc with a piston micropipette. The inoculm was immediately spread on the whole mini-disc with a specially designed flame sterilizable platinum-Mini-spreader (Fig. 2a). No spinning of the plate was needed. Alternatively the dropping pipette and spreader was replaced by a calibrated platinum wire Loop-spreader (Fig. 2b). A loop of 3 mm internal diameter made from a platinum-iridium wire of 0.75 mm thickness proved most useful and carried a drop of 10 micronl. Differences especially in surface tension of various diluting fluids did not influence to drop of this size and no recalibration was needed for water and nutrient broth. The loop was further shaped to Loop-spreader form. From each bacterial suspension 10 micronl were carried and spread on each mini-disc. The method is useful for pathogenic organisms as the loop can readily be flame sterilized. For routine purposes where only approximate numbers of bacteria need to be known a still rapid semiquantitative method was deviced making use of a calibrated stainless steel Stamping-disc (Fig. 2c). A disc of 25mm diameter and 1 mm thickness delivered approximateyl 10 microlitres of supensions and was found to be most useful to stamp seven dilutions on a single plate. In collections and bacteriology laboratories where by conventional methods large number of plates are to be plated and counted the presented techniques could prove most convenient, rapid and economical.
ESTIMATION OF THE NUMBER OF INFECTIOUS BACTERIAL OR VIRAL PARTICLES BY THE DILUTION METHOD
Seligman, Stephen J.; Mickey, M. Ray
1964-01-01
Seligman, Stephen J. (University of California, Los Angeles), and M. Ray Mickey. Estimation of the number of infectious bacterial or viral particles by the dilution method. J. Bacteriol. 88:31–36. 1964.—For viral or bacterial systems in which discrete foci of infection are not obtainable, it is possible to obtain an estimate of the number of infectious particles by use of the quantal response if the assay system is such that one infectious particle can elicit the response. Unfortunately, the maximum likelihood estimate is difficult to calculate, but, by the use of a modification of Haldane's approximation, it is possible to construct a table which facilitates calculation of both the average number of infectious particles and its relative error. Additional advantages of the method are that the number of test units per dilution can be varied, the dilutions need not bear any fixed relation to each other, and the one-particle hypothesis can be readily tested. PMID:14197902
The effect of clary sage oil on staphylococci responsible for wound infections.
Sienkiewicz, Monika; Głowacka, Anna; Poznańska-Kurowska, Katarzyna; Kaszuba, Andrzej; Urbaniak, Anna; Kowalczyk, Edward
2015-02-01
The spreading of bacterial antibiotic resistance among clinical strains of pathogenic bacteria has made investigators to search for other active antibacterial agents which could provide a valuable complement to the existing therapies. To determine the antibacterial activity of clary sage oil (Salvia sclarea L.) against Staphylococcus clinical strains which were isolated from patients with wound infections. A comprehensive evaluation of Staphylococcus clinical strain resistance to antibiotics was performed. The constituents of clary sage oil were assayed by GC-FID-MS analysis. The minimal inhibitory concentration (MIC) of the tested essential oil against staphylococci by the micro-dilution broth method was determined. The clary sage oil was active against Staphylococcus aureus, S. epidermidis and S. xylosus with MIC values ranging from 3.75 to 7.00 µl/ml. The results of the in vitro tests encourage to use formulations containing sage oil as the active natural antimicrobial agent. Because of its antimicrobial properties clary sage oil may be applied to treat wounds and skin infections.
Molecular typing and antimicrobial susceptibility of Clostridium perfringens from broiler chickens.
Gharaibeh, Saad; Al Rifai, Rami; Al-Majali, Ahmad
2010-12-01
Clostridium perfringens (Cp) causes necrotic enteritis disease in commercial poultry. Antimicrobials are used to control and treat this disease and sometimes clinical outbreaks do not respond well to certain treatments. This study was designed to isolate Cp from clinical cases, type these isolates by multiplex PCR, and determine their antimicrobial susceptibility by micro-dilution method. A total of 67 Cp isolates were obtained from 155 broiler chicken flocks. All isolates were classified as type A and non-enterotoxin producers. Lincomycin, erythromycins, and tilmicosin showed very high minimal inhibitory concentration (MIC) 50 of ≥256 μg/ml. However, tylosin, amoxicillin, ampicillin, penicillin, florfenicol, danofloxacin, enrofloxacin, chlortetracycline, doxycycline, and oxytetracycline had variable MIC₅₀ of 64, 0.5, 1, 1, 8, 4, 8, 4, 8, 0.5 μg/ml, respectively. It is recommended that Cp infections in Jordan be treated with either penicillins or tetracyclines especially amoxicillin and oxytetracycline. Copyright © 2010 Elsevier Ltd. All rights reserved.
Mothana, Ramzi; Alsaid, Mansour; Khaled, Jamal M; Alharbi, Naiyf S; Alatar, Abdulrahman; Raish, Mohammad; Al-Yahya, Mohammed; Rafatullah, Syed; Parvez, Mohammad Khalid; Ahamad, Syed Rizwan
2016-03-01
This study was designed to investigate the possible antiniciceptive, antipyretic and antimicrobial activities of the essential oil obtained from the fruits of Piper Cubeba (L.). To assess the antinociceptive and antipyretic activities, three doses (150, 300 and 600 mg/kg, i.p.) were tested in acetic acid-induced abdominal writhing, tail flick reaction and hot-plate and Brewer's yeast-induced hyperpyrexia test models in animals. Moreover, the antimicrobial activity was examined using agar diffusion method and broth micro-dilution assay for minimum inhibitory concentrations (MIC). The Piper Cubeba essential oil (PCEO) showed a marked antinociception (17, 30 and 54%) and an increase in reaction time in mice in the flick tailed and hot-plate tests. The brewer's yeast induced hyperpyrexia was decreased in a dose dependent manner. PCEO also exhibited a strong antimicrobial potential. These findings confirm the traditional analgesic indications of P. cubeba oil and provide persuasive evidence and support its use in Arab traditional medicine.
Xian, Yanping; Wu, Yuluan; Dong, Hao; Guo, Xindong; Wang, Bin; Wang, Li
2017-09-29
The present work presents a novel and rapid analytical method for the simultaneous analysis of bisphenol A (BPA), bisphenol B (BPB), bisphenol F (BPF) and bisphenol S (BPS) in edible oil based on dispersive micro solid phase extraction (DMSPE) for the first time followed by isotope dilution-ultra high performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS). The edible oil sample was dispersed by n-hexane and extracted with ammoniated methanol-water solution. Then the target analytes were dispersedly absorbed using the polymer anion exchange (PAX) as the sorbent and eluted by acidic methanol. After that, four bisphenols were separated on a C18 column by gradient elution with methanol and 0.05% ammonium hydroxide in water as mobile phase, detected by MS/MS under multiple reactions monitoring (MRM) mode and quantified by internal standard method. The PAX amounts, adsorption time, concentrations of formic acid in the elution solvent and volume of elution solvent for the DMSPE technique were optimized. The limit of detection and quantitation (LOD and LOQ), matrix effect, recovery and precision of the developed method were investigated. Results indicated that BPS and the rest three bisphenols displayed excellent linearity in the concentration ranges of 0.1-50μg/L and 0.5-250μg/L, respectively, with correlation coefficients (R 2 ) all larger than 0.998. Achieved MLODs (S/N=3) varied between 0.1-0.4μg/kg for all bisphenols. The mean recoveries at three spiked levels in edible oil were in the range of 87.3-108%. Intra-day precision (n=6) and inter-day precision (n=5) were <9% and <11%, respectively. This method is of rapid-and-simple pretreatment, accurate and sensitive, and suitable for the simultaneous determination of bisphenols in edible oil. Copyright © 2017. Published by Elsevier B.V.
Boulyga, Sergei F; Heilmann, Jens; Heumann, Klaus G
2005-08-01
Inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) with direct laser-assisted introduction of isotope-diluted samples into the plasma, using a laser ablation system with high ablation rates, was developed for accurate sulfur determinations in different petroleum products such as 'sulfur-free' premium gasoline, diesel fuel, and heating oil. Two certified gas oil reference materials were analyzed for method validation. Two different 34S-enriched spike compounds, namely, elementary sulfur dissolved in xylene and dibenzothiophene in hexane, were synthesized and tested for their usefulness in this isotope dilution technique. The isotope-diluted sample was adsorbed on a filter-paper-like material, which was fixed in a special holder for irradiation by the laser beam. Under these conditions no time-dependent spike/analyte fractionation was only observed for the dibenzothiophene spike during the laser ablation process, which means that the measured 34S/32S isotope ratio of the isotope-diluted sample remained constant-a necessary precondition for accurate results with the isotope dilution technique. A comparison of LA-ICP-IDMS results with the certified values of the gas oil reference materials and with results obtained from ICP-IDMS analyses with wet sample digestion demonstrated the accuracy of the new LA-ICP-IDMS method in the concentration range of 9.2 microg g(-1) ('sulfur-free' premium gasoline) to 10.4 mg g(-1) (gas oil reference material BCR 107). The detection limit for sulfur by LA-ICP-IDMS is 0.04 microg g(-1) and the analysis time is only about 10 min, which therefore also qualifies this method for accurate determinations of low sulfur contents in petroleum products on a routine level.
Li, Rufeng; Wang, Yibei; Xu, Hong; Fei, Baowei; Qin, Binjie
2017-01-01
This paper developed and evaluated a quantitative image analysis method to measure the concentration of the nanoparticles on which alkaline phosphatase (AP) was immobilized. These AP-labeled nanoparticles are widely used as signal markers for tagging biomolecules at nanometer and sub-nanometer scales. The AP-labeled nanoparticle concentration measurement can then be directly used to quantitatively analyze the biomolecular concentration. Micro-droplets are mono-dispersed micro-reactors that can be used to encapsulate and detect AP-labeled nanoparticles. Micro-droplets include both empty micro-droplets and fluorescent micro-droplets, while fluorescent micro-droplets are generated from the fluorescence reaction between the APs adhering to a single nanoparticle and corresponding fluorogenic substrates within droplets. By detecting micro-droplets and calculating the proportion of fluorescent micro-droplets to the overall micro-droplets, we can calculate the AP-labeled nanoparticle concentration. The proposed micro-droplet detection method includes the following steps: (1) Gaussian filtering to remove the noise of overall fluorescent targets, (2) a contrast-limited, adaptive histogram equalization processing to enhance the contrast of weakly luminescent micro-droplets, (3) an red maximizing inter-class variance thresholding method (OTSU) to segment the enhanced image for getting the binary map of the overall micro-droplets, (4) a circular Hough transform (CHT) method to detect overall micro-droplets and (5) an intensity-mean-based thresholding segmentation method to extract the fluorescent micro-droplets. The experimental results of fluorescent micro-droplet images show that the average accuracy of our micro-droplet detection method is 0.9586; the average true positive rate is 0.9502; and the average false positive rate is 0.0073. The detection method can be successfully applied to measure AP-labeled nanoparticle concentration in fluorescence microscopy. PMID:29160812
Li, Rufeng; Wang, Yibei; Xu, Hong; Fei, Baowei; Qin, Binjie
2017-11-21
This paper developed and evaluated a quantitative image analysis method to measure the concentration of the nanoparticles on which alkaline phosphatase (AP) was immobilized. These AP-labeled nanoparticles are widely used as signal markers for tagging biomolecules at nanometer and sub-nanometer scales. The AP-labeled nanoparticle concentration measurement can then be directly used to quantitatively analyze the biomolecular concentration. Micro-droplets are mono-dispersed micro-reactors that can be used to encapsulate and detect AP-labeled nanoparticles. Micro-droplets include both empty micro-droplets and fluorescent micro-droplets, while fluorescent micro-droplets are generated from the fluorescence reaction between the APs adhering to a single nanoparticle and corresponding fluorogenic substrates within droplets. By detecting micro-droplets and calculating the proportion of fluorescent micro-droplets to the overall micro-droplets, we can calculate the AP-labeled nanoparticle concentration. The proposed micro-droplet detection method includes the following steps: (1) Gaussian filtering to remove the noise of overall fluorescent targets, (2) a contrast-limited, adaptive histogram equalization processing to enhance the contrast of weakly luminescent micro-droplets, (3) an red maximizing inter-class variance thresholding method (OTSU) to segment the enhanced image for getting the binary map of the overall micro-droplets, (4) a circular Hough transform (CHT) method to detect overall micro-droplets and (5) an intensity-mean-based thresholding segmentation method to extract the fluorescent micro-droplets. The experimental results of fluorescent micro-droplet images show that the average accuracy of our micro-droplet detection method is 0.9586; the average true positive rate is 0.9502; and the average false positive rate is 0.0073. The detection method can be successfully applied to measure AP-labeled nanoparticle concentration in fluorescence microscopy.
[Polymerase chain reaction (PCR) for the identification of toxigenic Vibrio cholerae O1 in oysters].
Rodríguez-Angeles, M G; Giono-Cerezo, S; Moreno-Escobar, A; Valdespino-Gómez, J L
1994-01-01
PCR was made with ctx2 (CGG GCA GAT TCT AGA CCT CCT G) y ctx3 (CGA TGA TCT TGG AGC ATT CCC AC) primers for subunit A of cholera toxin, 30 cycles of temperature on samples of 50 g of oysters added in 450 ml of peptone alcaline water that were inoculated with 15 x 10(6), 0.75 x 10(6) and 0.15 x 10(6) CFU/ml of toxigenic 6707 V. cholerae O1 reference strain. The samples were tested by three microbiological methods: INDRE's method uses 1 x 10(-1) dilution of sample, two fold pass to peptone alcaline water pH 9 incubated 18 h and 6 h at 37 degrees C, the Food and Drugs Administration (FDA) method uses 10(-1) to 10(-6) dilutions of sample, 6 h incubation and reincubation for 18 h at 37 and 42 degrees C and the Mexican laboratories (LMD) with 10(-4) to 10(-3) dilutions, the samples were incubated for 6 h and then reincubated for 18 h at two temperatures 37 and 42 degrees C. The PCR by INDRE's method was positive with 3 x 10(2) CFU/ml/g oyster. In the FDA's method the PCR detected DNA in 10(-4) dilution with 3 x 10(1) CFU/ml/g oyster and in LMD's method the PCR was positive in 10(-3) with 3 CFU/ml/g oyster. The results of the PCR were obtained between 5-6 h, and later V. cholerae O1 was isolated by three microbiological methods. The PCR reproducibility was better on DNA sample diluted 1:4 and 10 microliters of sample increased from 1:1000 to 1:10000 the sensitivity of PCR.
An accurate algorithm for the detection of DNA fragments from dilution pool sequencing experiments.
Bansal, Vikas
2018-01-01
The short read lengths of current high-throughput sequencing technologies limit the ability to recover long-range haplotype information. Dilution pool methods for preparing DNA sequencing libraries from high molecular weight DNA fragments enable the recovery of long DNA fragments from short sequence reads. These approaches require computational methods for identifying the DNA fragments using aligned sequence reads and assembling the fragments into long haplotypes. Although a number of computational methods have been developed for haplotype assembly, the problem of identifying DNA fragments from dilution pool sequence data has not received much attention. We formulate the problem of detecting DNA fragments from dilution pool sequencing experiments as a genome segmentation problem and develop an algorithm that uses dynamic programming to optimize a likelihood function derived from a generative model for the sequence reads. This algorithm uses an iterative approach to automatically infer the mean background read depth and the number of fragments in each pool. Using simulated data, we demonstrate that our method, FragmentCut, has 25-30% greater sensitivity compared with an HMM based method for fragment detection and can also detect overlapping fragments. On a whole-genome human fosmid pool dataset, the haplotypes assembled using the fragments identified by FragmentCut had greater N50 length, 16.2% lower switch error rate and 35.8% lower mismatch error rate compared with two existing methods. We further demonstrate the greater accuracy of our method using two additional dilution pool datasets. FragmentCut is available from https://bansal-lab.github.io/software/FragmentCut. vibansal@ucsd.edu. Supplementary data are available at Bioinformatics online. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com
Felix, Larry Gordon; Farthing, William Earl; Irvin, James Hodges; Snyder, Todd Robert
2010-05-11
A dilution apparatus for diluting a gas sample. The apparatus includes a sample gas conduit having a sample gas inlet end and a diluted sample gas outlet end, and a sample gas flow restricting orifice disposed proximate the sample gas inlet end connected with the sample gas conduit and providing fluid communication between the exterior and the interior of the sample gas conduit. A diluted sample gas conduit is provided within the sample gas conduit having a mixing end with a mixing space inlet opening disposed proximate the sample gas inlet end, thereby forming an annular space between the sample gas conduit and the diluted sample gas conduit. The mixing end of the diluted sample gas conduit is disposed at a distance from the sample gas flow restricting orifice. A dilution gas source connected with the sample gas inlet end of the sample gas conduit is provided for introducing a dilution gas into the annular space, and a filter is provided for filtering the sample gas. The apparatus is particularly suited for diluting heated sample gases containing one or more condensable components.
A comparative evaluation of six principal IgY antibody extraction methods.
Ren, Hao; Yang, Wenjing; Thirumalai, Diraviyam; Zhang, Xiaoying; Schade, Rüdiger
2016-03-01
Egg yolk has been considered a promising source of antibodies. Our study was designed to compare six principal IgY extraction methods (water dilution, polyethylene glycol [PEG] precipitation, caprylic acid extraction, chloroform extraction, phenol extraction, and carrageenan extraction), and to assess their relative extraction efficiencies and the purity of the resulting antibodies. The results showed that the organic solvents (chloroform or phenol) minimised the lipid ratio in the egg yolk. The water dilution, PEG precipitation and caprylic acid extraction methods resulted in high yields, and antibodies purified with PEG and carrageenan exhibited high purity. Our results indicate that phenol extraction would be more suitable for preparing high concentrations of IgY for non-therapeutic usage, while the water dilution and carrageenan extraction methods would be more appropriate for use in the preparation of IgY for oral administration. 2016 FRAME.
Watanabe, Evandro; Tanomaru, Juliane Maria Guerreiro; Nascimento, Andresa Piacezzi; Matoba, Fumio; Tanomaru, Mario; Ito, Izabel Yoko
2008-01-01
The aim of this in vitro study was to determine the maximum inhibitory dilution (MID) of four cetylpyridinium chloride (CPC)-based mouthwashes: CPC+Propolis, CPC+Malva, CPC+Eucaliptol+Juá+Romã+Propolis (Natural Honey®) and CPC (Cepacol®), against 28 Staphylococcus aureus field strains, using the agar dilution method. Decimal dilutions ranging from 1/10 to 1/ 655,360 were prepared and added to Mueller Hinton Agar. Strains were inoculated using Steers multipoint inoculator. The inocula were seeded onto the surface of the culture medium in Petri dishes containing different dilutions of the mouthwashes. The dishes were incubated at 37°C for 24 h. For readings, the MID was considered as the maximum dilution of mouthwash still capable of inhibiting microbial growth. The obtained data showed that CPC+Propolis had antimicrobial activity against 27 strains at 1/320 dilution and against all 28 strains at 1/160 dilution, CPC+Malva inhibited the growth of all 28 strains at 1/320 dilution, CPC+Eucaliptol+Juá+Romã+Propolis inhibited the growth of 2 strains at 1/640 dilution and all 28 strains at 1/320 dilution, and Cepacol® showed antimicrobial activity against 3 strains at 1/320 dilution and against all 28 strains at 1/160 dilution. Data were submitted to Kruskal-Wallis test, showing that the MID of Cepacol® was lower than that determined for the other products (p<0.05). In conclusion, CPC-mouthwashes showed antimicrobial activity against S. aureus and the addition of other substances to CPC improved its antimicrobial effect. PMID:19089260
Synthetic Biology in Aqueous Compartments at the Micro- and Nanoscale
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boreyko, Jonathan; Caveney, Patrick M.; Norred, Sarah L.
ABSTRACT Aqueous two-phase systems and related emulsion-based structures defined within micro- and nanoscale environments enable a bottom-up synthetic biological approach to mimicking the dynamic compartmentation of biomaterial that naturally occurs within cells. Model systems we have developed to aid in understanding these phenomena include on-demand generation and triggering of reversible phase transitions in ATPS confined in microscale droplets, morpho-logical changes in networks of femtoliter-volume aqueous droplet interface bilayers (DIBs) formulated in microfluidic channels, and temperature-driven phase transitions in interfacial lipid bilayer systems supported on micro and nanostructured substrates. For each of these cases, the dynamics were intimately linked to changesmore » in the chemical potential of water, which becomes increasingly susceptible to confinement and crowding. At these length scales, where interfacial and surface areas predominate over compartment volumes, both evaporation and osmotic forces become enhanced relative to ideal dilute solutions. Finally, consequences of confinement and crowding in cell-sized microcompartments for increasingly complex scenarios will be discussed, from single-molecule mobility measurements with fluorescence correlation spectroscopy to spatio-temporal modulation of resource sharing in cell-free gene expression bursting.« less
NASA Astrophysics Data System (ADS)
Liu, Mingliang; Lü, Zhe; Wei, Bo; Huang, Xiqiang; Zhang, Yaohui; Su, Wenhui
An annular micro-stack array consisting of four fuel cells has been fabricated and operated successfully in single-chamber conditions using a nitrogen-diluted oxygen-methane mixture as the operating gas. The single cells consist of a state-of-the-art porous NiO/Y 2O 3-stabilized ZrO 2 (YSZ) anode support, a YSZ electrolyte membrane and a modified La 0.7Sr 0.3MnO 3 (LSM) cathode. The annular configuration of the array is favorable for utilizing the heating effect. The maximum power output of the annular stack decreases with increasingCH 4/O 2 ratio. Its performance increases with increasing CH 4 flow rate and decreases with increasing N 2 flow rate. The power output of the stack is ∼380 mW at CH 4/O 2 = 1 and an N 2 flow rate of 100 sccm and the average maximum power density of each cell is ∼190 mW cm -2. The average performance of each cell in the annular micro-stack array is higher than that of an additional single cell placed next to the stack.
CAVITATION THRESHOLD OF MICROBUBBLES IN GEL TUNNELS BY FOCUSED ULTRASOUND
Sassaroli, E.; Hynynen, K.
2007-01-01
The investigation of inertial cavitation in micro-tunnels has significant implications for the development of therapeutic applications of ultrasound such as ultrasound-mediated drug and gene delivery. The threshold for inertial cavitation was investigated using a passive cavitation detector with a center frequency of 1 MHz. Micro-tunnels of various diameters (90 to 800 μm) embedded in gel were fabricated and injected with a solution of Optison™ contrast agent of concentrations 1.2% and 0.2% diluted in water. An ultrasound pulse of duration 500 ms and center frequency 1.736 MHz was used to insonate the microbubbles. The acoustic pressure was increased at one second intervals until broadband noise emission was detected. The pressure threshold at which broadband noise emission was observed was found to be dependent on the diameter of the micro-tunnels, with an average increase of 1.2 to 1.5 between the smallest and the largest tunnels, depending on the microbubble concentration. The evaluation of inertial cavitation in gel tunnels rather than tubes provides a novel opportunity to investigate microbubble collapse in a situation that simulates in vivo blood vessels better than tubes with solid walls do. PMID:17590501
Synthetic Biology in Aqueous Compartments at the Micro- and Nanoscale
Boreyko, Jonathan; Caveney, Patrick M.; Norred, Sarah L.; ...
2017-07-10
ABSTRACT Aqueous two-phase systems and related emulsion-based structures defined within micro- and nanoscale environments enable a bottom-up synthetic biological approach to mimicking the dynamic compartmentation of biomaterial that naturally occurs within cells. Model systems we have developed to aid in understanding these phenomena include on-demand generation and triggering of reversible phase transitions in ATPS confined in microscale droplets, morpho-logical changes in networks of femtoliter-volume aqueous droplet interface bilayers (DIBs) formulated in microfluidic channels, and temperature-driven phase transitions in interfacial lipid bilayer systems supported on micro and nanostructured substrates. For each of these cases, the dynamics were intimately linked to changesmore » in the chemical potential of water, which becomes increasingly susceptible to confinement and crowding. At these length scales, where interfacial and surface areas predominate over compartment volumes, both evaporation and osmotic forces become enhanced relative to ideal dilute solutions. Finally, consequences of confinement and crowding in cell-sized microcompartments for increasingly complex scenarios will be discussed, from single-molecule mobility measurements with fluorescence correlation spectroscopy to spatio-temporal modulation of resource sharing in cell-free gene expression bursting.« less
Hillis, L D; Winniford, M D; Jackson, J A; Firth, B G
1985-01-01
Of the various techniques that are available to assess the presence and magnitude of intracardiac shunting, oximetry and indicator dilution are used most frequently. This study was performed to compare these methods in adult patients with pure left-to-right intracardiac shunting. In 27 patients [12 men, 15 women, aged 32 +/- 12 (mean +/- SD) years], shunt magnitude was assessed in close temporal proximity by both techniques. The oximetric percentage left-to-right shunt averaged 55 +/- 16%, whereas the indocyanine green dye percentage shunt was significantly less (36 +/- 14%, p less than 0.001). The oximetric percentage shunt exceeded the indocyanine green dye percentage shunt in 26 and did so by greater than 20% in 23 patients. Thus, there is a substantial difference in shunt magnitude between the oximetric and the indicator dilution techniques. In infants, indicator dilution yields results that are larger than those obtained with the oximetric method. Conversely, in adults, the indicator dilution technique gives results that are consistently smaller than those obtained with oximetry. As a result, the decision regarding therapy of an intracardiac shunt should be made with this in mind.
Milton, Martin J T; Wang, Jian
2003-01-01
A new isotope dilution mass spectrometry (IDMS) method for high-accuracy quantitative analysis of gases has been developed and validated by the analysis of standard mixtures of carbon dioxide in nitrogen. The method does not require certified isotopic reference materials and does not require direct measurements of the highly enriched spike. The relative uncertainty of the method is shown to be 0.2%. Reproduced with the permission of Her Majesty's Stationery Office. Copyright Crown copyright 2003.
NASA Astrophysics Data System (ADS)
Felici, Marco; Birindelli, Simone; Trotta, Rinaldo; Francardi, Marco; Gerardino, Annamaria; Notargiacomo, Andrea; Rubini, Silvia; Martelli, Faustino; Capizzi, Mario; Polimeni, Antonio
2014-12-01
In dilute-nitride semiconductors, the possibility to selectively passivate N atoms by spatially controlled hydrogen irradiation allows for tailoring the effective N concentration of the host—and, therefore, its electronic and structural properties—with a precision of a few nanometers. In the present work, this technique is applied to the realization of ordered arrays of GaAs1 -xNx/GaAs1 -xNx∶H wires oriented at different angles with respect to the crystallographic axes of the material. The creation of a strongly anisotropic strain field in the plane of the sample, due to the lattice expansion of the fully hydrogenated regions surrounding the GaAs1 -xNx wires, is directly responsible for the peculiar polarization properties observed for the wire emission. Temperature-dependent polarization-resolved microphotoluminescence measurements, indeed, reveal a nontrivial dependence of the degree of linear polarization on the wire orientation, with maxima for wires parallel to the [110] and [1 1 ¯ 0 ] directions and a pronounced minimum for wires oriented along the [100] axis. In addition, the polarization direction is found to be precisely perpendicular to the wire when the latter is oriented along high-symmetry crystal directions, whereas significant deviations from a perfect orthogonality are measured for all other wire orientations. These findings, which are well reproduced by a theoretical model based on finite-element calculations of the strain profile of our GaAs1 -xNx/GaAs1 -xNx∶H heterostructures, demonstrate our ability to control the polarization properties of dilute-nitride micro- and nanostructures via H-assisted strain engineering. This additional degree of freedom may prove very useful in the design and optimization of innovative photonic structures relying on the integration of dilute-nitride-based light emitters with photonic crystal microcavities.
Determination of copper by isotopic dilution.
Faquim, E S; Munita, C S
1994-01-01
A rapid and selective method was used for the determination of copper by isotopic dilution employing substoichiometric extraction with dithizone in carbon tetrachloride. The appropriate pH range for the substoichiometric extraction was 2-7. In the analysis, even a large excess of elements forming extractable complexes with dithizone does not interfere. The accuracy and precision of the method were evaluated. The method has been applied to analysis of reference materials, wheat flour, wine, and beer.
García, M. T.; Pelaz, C.; Giménez, M. J.; Aguilar, L.
2000-01-01
The MICs at which 90% of isolates are inhibited for gemifloxacin, trovafloxacin, and grepafloxacin were low (≤0.01 μg/ml) for 271 Legionella isolates when they were determined by the broth microdilution method but increased (≥6 dilutions) when they were determined by the agar dilution method. This was due to the charcoal in the agar dilution medium, as shown by the progressive decrease in the MICs when the charcoal concentrations decreased. As free drug is the active fraction, charcoal binding should be considered. PMID:10898695
Bogavac, M; Karaman, M; Janjušević, Lj; Sudji, J; Radovanović, B; Novaković, Z; Simeunović, J; Božin, B
2015-09-01
The aims of study were to examine the antibacterial potential of two commercial essential oils (EOs) from coriander (Coriandrum sativum L.) and thyme (Thymus vulgaris L.) against vaginal clinical strains of bacteria and yeast and their chemical composition. Antimicrobial activities of commercial essential oils were determined using macro-diffusion (disc, well) and micro-dilution method in 96-well micro plates against twelve clinical strains of bacteria: Escherichia coli, Proteus mirabilis, Staphylococcus aureus and Enterococcus sp., Staph. aureus ATCC 25923, ATCC 6538 and E. coli 25922 and two clinical Candida albicans strains, including ATTC 10231. Spectrophotometric method was used for determination on C. albicans growth. An antimicrobial effect of EOs was strain specific. Bactericidal activity was higher for coriander EO (minimal inhibitory concentration (MICs) 0·4-45·4 μl ml(-1)) against almost all tested bacteria, except multiple resistant strains of Eneterococcus sp. and Proteus sp. Thyme EO showed slightly better fungicidal activity reaching MIC at 0·11 mg ml(-1) for all C. albicans strains. The effect of EOs on biofilm-forming ability was tested for two strains of Staph. aureus and E. coli, as well as on C. albicans filamentation ability. Brine shrimp lethality bioassay revealed thymus oil total toxicity and coriander oil intoxicity (LC50 = 2·25 mg ml(-1)). The chemical composition of oils was analysed by gas chromatography mass spectrometry showing oxygenated monoterepenes as dominant constituents. The results provide in-vitro scientific support for the safety possible use of Coriander EO against E. coli, Staph. aureus and C. albicans vaginal infections in alternative gynaecological treatment. To examine EOs as possible constituent of naturally based antimicrobial agents in vaginaletes for safety gynaecological application. © 2015 The Society for Applied Microbiology.
Fischer, H; Pusch, M
1999-10-01
Bacterial production is a key parameter for the understanding of carbon cycling in aquatic ecosystems, yet it remains difficult to measure in many aquatic habitats. We therefore tested the applicability of the [(14)C]leucine incorporation technique for the measurement of bulk bacterial production in various habitats of a lowland river ecosystem. To evaluate the method, we determined (i) extraction efficiencies of bacterial protein from the sediments, (ii) substrate saturation of leucine in sediments, the biofilms on aquatic plants (epiphyton), and the pelagic zone, (iii) bacterial activities at different leucine concentrations, (iv) specificity of leucine uptake by bacteria, and (v) the effect of the incubation technique (perfused-core incubation versus slurry incubation) on leucine incorporation into protein. Bacterial protein was best extracted from sediments and precipitated by hot trichloroacetic acid treatment following ultrasonication. For epiphyton, an alkaline-extraction procedure was most efficient. Leucine incorporation saturation occurred at 1 microM in epiphyton and 100 nM in the pelagic zone. Saturation curves in sediments were difficult to model but showed the first level of leucine saturation at 50 microM. Increased uptake at higher leucine concentrations could be partly attributed to eukaryotes. Addition of micromolar concentrations of leucine did not enhance bacterial electron transport activity or DNA replication activity. Similar rates of leucine incorporation into protein calculated for whole sediment cores were observed after slurry and perfused-core incubations, but the rates exhibited strong vertical gradients after the core incubation. We conclude that the leucine incorporation method can measure bacterial production in a wide range of aquatic habitats, including fluvial sediments, if substrate saturation and isotope dilution are determined.
Arndt, Stefan K; Irawan, Andi; Sanders, Gregor J
2015-12-01
Relative water content (RWC) and the osmotic potential (π) of plant leaves are important plant traits that can be used to assess drought tolerance or adaptation of plants. We estimated the magnitude of errors that are introduced by dilution of π from apoplastic water in osmometry methods and the errors that occur during rehydration of leaves for RWC and π in 14 different plant species from trees, grasses and herbs. Our data indicate that rehydration technique and length of rehydration can introduce significant errors in both RWC and π. Leaves from all species were fully turgid after 1-3 h of rehydration and increasing the rehydration time resulted in a significant underprediction of RWC. Standing rehydration via the petiole introduced the least errors while rehydration via floating disks and submerging leaves for rehydration led to a greater underprediction of RWC. The same effect was also observed for π. The π values following standing rehydration could be corrected by applying a dilution factor from apoplastic water dilution using an osmometric method but not by using apoplastic water fraction (AWF) from pressure volume (PV) curves. The apoplastic water dilution error was between 5 and 18%, while the two other rehydration methods introduced much greater errors. We recommend the use of the standing rehydration method because (1) the correct rehydration time can be evaluated by measuring water potential, (2) overhydration effects were smallest, and (3) π can be accurately corrected by using osmometric methods to estimate apoplastic water dilution. © 2015 Scandinavian Plant Physiology Society.
A method for measuring particle number emissions from vehicles driving on the road.
Shi, J P; Harrison, R M; Evans, D E; Alam, A; Barnes, C; Carter, G
2002-01-01
Earlier research has demonstrated that the conditions of dilution of engine exhaust gases profoundly influence the size distribution and total number of particles emitted. Since real world dilution conditions are variable and therefore difficult to simulate, this research has sought to develop and validate a method for measuring particle number emissions from vehicles driving past on a road. This has been achieved successfully using carbon dioxide as a tracer of exhaust gas dilution. By subsequent adjustment of data to a constant dilution factor, it is possible to compare emissions from different vehicles using different technologies and fuels based upon real world emission data. Whilst further optimisation of the technique, especially in terms of matching the instrument response times is desirable, the measurements offer useful insights into emissions from gasoline and diesel vehicles, and the substantial proportion of particles emitted in the 3-7 nanometre size range.
Moreno-González, David; Alcántara-Durán, Jaime; Gilbert-López, Bienvenida; Beneito-Cambra, Miriam; Cutillas, Víctor M; Rajski, Łukasz; Molina-Díaz, Antonio; García-Reyes, Juan F
2018-03-01
In this work, a new method based on nanoflow LC with high-resolution MS was developed for the determination of eight pesticides in pollen and nectar samples, including neonicotinoid insecticides and other selected pesticides commonly found in bees and beeswax. Detection was undertaken with a hybrid quadrupole-Orbitrap mass spectrometer (Q Exactive™) equipped with a commercial nanospray ion source. The extraction of pesticides from pollen samples was performed by a modified micro-QuEChERS method scaled down to Eppendorf tubes, whereas nectar samples were simply diluted with a water-methanol (95 + 5, v/v) solution. Good linearity (>0.999 in all cases) was obtained between 0.05 and 500 µg/kg and between 0.04 and 400 µg/kg for pollen and nectar, respectively. Recovery rates in pollen ranged from 85 to 97%, with RSDs <12%. Matrix effect was evaluated and showed negligible effects for all studied pesticides. The lowest concentration levels tested and validated were 0.5 and 0.4 µg/kg for pollen and nectar matrixes, respectively. In addition, selected incurred samples were studied, obtaining several positive findings in pollen and nectar samples, demonstrating the sensitivity and applicability of the proposed method.
Bjørn, Anders; Diamond, Miriam; Birkved, Morten; Hauschild, Michael Zwicky
2014-11-18
The ecological footprint method has been successful in communicating environmental impacts of anthropogenic activities in the context of ecological limits. We introduce a chemical footprint method that expresses ecotoxicity impacts from anthropogenic chemical emissions as the dilution needed to avoid freshwater ecosystem damage. The indicator is based on USEtox characterization factors with a modified toxicity reference point. Chemical footprint results can be compared to the actual dilution capacity within the geographic vicinity receiving the emissions to estimate whether its ecological limit has been exceeded and hence whether emissions can be expected to be environmentally sustainable. The footprint method was illustrated using two case studies. The first was all inventoried emissions from European countries and selected metropolitan areas in 2004, which indicated that the dilution capacity was likely exceeded for most European countries and all landlocked metropolitan areas. The second case study indicated that peak application of pesticides alone was likely to exceed Denmark's freshwater dilution capacity in 1999-2011. The uncertainty assessment showed that better spatially differentiated fate factors would be useful and pointed out other major sources of uncertainty and some opportunities to reduce these.
Comparative activity of several beta-lactam antibiotics against anaerobes determined by two methods.
Zabransky, R J; Birk, R J
1987-01-01
The susceptibility of 120 strains of several species of anaerobes to a number of second and third generation beta-lactam antibiotics was determined by the National Committee for Clinical Laboratory Standards reference agar dilution and microdilution methods. The antibiotics tested were cefoperazone, cefotaxime, cefotetan, ceftizoxime, cefoxitin, and imipenem. The MIC50s ranged from 0.125 to 16 micrograms/ml. The MIC90s were lowest with imipenem at 0.5 micrograms/ml, followed by cefoxitin at 32 micrograms/ml; they were highest with cefotetan at 128 micrograms/ml and were 64 micrograms/ml with the others. In vitro drug activity varied with the antibiotic, the organism, the method used, and the breakpoint selected. Rates of resistance varied considerably between the taxonomic groups of organisms tested and also among species within a group. Overall, reproducibility with the agar dilution method ranged from 44% to 85%; testing with ceftizoxime was the least reproducible. Microdilution results agreed within +/- 1 dilution of the agar dilution mode 79% to 95% of the time, with some variation between drugs and organisms tested. Because there were distinct differences in the activity of some drugs against certain species, no antibiotic can substitute for others in in vitro testing.
2014-01-01
Background Endophytes, which reside in plant tissues, have the potential to produce novel metabolites with immense benefits for health industry. Cytotoxic and antimicrobial activities of endophytic fungi isolated from Bacopa monnieri (L.) Pennell were investigated. Methods Endophytic fungi were isolated from the Bacopa monnieri. Extracts from liquid cultures were tested for cytotoxicity against a number of cancer cell lines using the MTT assay. Antimicrobial activity was determined using the micro dilution method. Results 22% of the examined extracts showed potent (IC50 of <20 μg/ml) cytotoxic activity against HCT-116 cell line. 5.5%, 11%, 11% of the extracts were found to be cytotoxic for MCF-7, PC-3, and A-549 cell lines respectively. 33% extracts displayed antimicrobial activity against at least one test organism with MIC value 10–100 μg/ml. The isolate B9_Pink showed the most potent cytotoxic activity for all the cell lines examined and maximum antimicrobial activity against the four pathogens examined which was followed by B19. Conclusions Results indicated the potential for production of bioactive agents from endophytes of Bacopa monnieri. PMID:24512530
Discharge rate measurements in a canal using radiotracer methods.
Pant, H J; Goswami, Sunil; Biswal, Jayashree; Samantray, J S; Sharma, V K
2016-06-01
Discharge rates of water were measured in a canal using radiotracer methods with an objective to validate the efficacy of Concrete Volute Pumps (CVPs) installed at various pumping stations along the canal. Pulse velocity and dilution methods were applied to measure the discharge rates using Iodine-131 as a radiotracer. The discharge rate measured in one of the sections of the canal using the pulse velocity method was found to be 22.5m(3)/s, whereas the discharge rates measured using the dilution method in four different sections of the canal varied from 20.27 to 20.62m(3)/s with single CVP in operation. The standard error in discharge rate measurements using dilution method ranged from ±1.1 to ±1.8%. The experimentally measured values of the discharge rate were in good agreement with the design value of the discharge rate (20m(3)/s) thus validating the performance of the CVPs used in the canal. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Negron, L. M.; Clague, J. W.; Gorski, D.; Amaya, M. A.; Pingitore, N. E.
2013-12-01
Millimeter- and micrometer-scale permeability of fine-grained igneous rocks has generated limited research interest. Nonetheless, the scale and distribution of such micro-permeability determines fluid penetration and pathways, parameters that define both the ability to heap leach a rock and the optimal grain size for such an operation. Texas Rare Earth Resources is evaluating the possibility of heap leaching of yttrium and heavy rare earth elements (YHREE) from the peraluminous rhyolite laccolith that forms one-mile-diameter Round Top Mountain. The YHREEs in this immense, surface-exposed deposit (minimum 1.6 billion tons, Texas Bureau Economic Geology) are dilute and diffuse, suggesting leaching as the best option for recovery. The REE grade is 0.05% and YHREEs comprise more than 70% of the total REE content. The YHREEs are hosted exclusively in micron-scale yttrofluorite grains, which proved soluble in dilute sulfuric acid. Laboratory experiments showed YHREE recoveries of up to 90%. Within limits, recoveries decrease with larger grain sizes, and increase with acid strength and exposure time. Our research question centers on dissolution effectiveness: Is YHREE recovery, relative to grain size, limited by (1) diffusion time of acid into, and dissolved solids, including YHREEs, out of the micro-permeability paths inherent in the rock particles; (2) the effective lengths of the natural micro-permeability paths in the rock; or (3) the putative role of the acid in dissolving new micro-paths into the grains? The maximum grain size should not exceed twice the typical path length (unless acid creates new paths), lest YHREEs in the core of a larger grain than that not be reached by acid. If instead diffusion time is limiting, longer leach time may prove effective. Rather than perform an extensive and expensive series of laboratory leaching experiments--some of which would be several months in duration--to determine optimal grain size, we developed a technique to efficiently determine the limits of penetration of water into the rhyolite. We cut parallel-sided slabs of Round Top rhyolite at staged thickness up to 10 mm. We then wet one side and view the opposite side over time under UV light to detect breakthrough of the fluorescein dye. Because of its extremely low visual detection limits, well below the ppm level, the dye has been widely used in biochemical research, as a tracer in surface and ground water studies, in delineating invisible cracks in such structural material as motor blocks, and in detecting corneal abrasions. We have been successful in detecting breakthrough at different rhyolite thicknesses. Continuing studies focus on mapping of the 2-dimensional distribution of the permeability via hand lens and low-power microscope; use of visible light dyes; and examination of specimens pre- and post-acid leaching to determine whether acid exposure produced significant new micro-permeability.
Shanks, Leslie; Siddiqui, M Ruby; Abebe, Almaz; Piriou, Erwan; Pearce, Neil; Ariti, Cono; Masiga, Johnson; Muluneh, Libsework; Wazome, Joseph; Ritmeijer, Koert; Klarkowski, Derryck
2015-05-14
Current WHO testing guidelines for resource limited settings diagnose HIV on the basis of screening tests without a confirmation test due to cost constraints. This leads to a potential risk of false positive HIV diagnosis. In this paper, we evaluate the dilution test, a novel method for confirmation testing, which is simple, rapid, and low cost. The principle of the dilution test is to alter the sensitivity of a rapid diagnostic test (RDT) by dilution of the sample, in order to screen out the cross reacting antibodies responsible for falsely positive RDT results. Participants were recruited from two testing centres in Ethiopia where a tiebreaker algorithm using 3 different RDTs in series is used to diagnose HIV. All samples positive on the initial screening RDT and every 10th negative sample underwent testing with the gold standard and dilution test. Dilution testing was performed using Determine™ rapid diagnostic test at 6 different dilutions. Results were compared to the gold standard of Western Blot; where Western Blot was indeterminate, PCR testing determined the final result. 2895 samples were recruited to the study. 247 were positive for a prevalence of 8.5 % (247/2895). A total of 495 samples underwent dilution testing. The RDT diagnostic algorithm misclassified 18 samples as positive. Dilution at the level of 1/160 was able to correctly identify all these 18 false positives, but at a cost of a single false negative result (sensitivity 99.6 %, 95 % CI 97.8-100; specificity 100 %, 95 % CI: 98.5-100). Concordance between the gold standard and the 1/160 dilution strength was 99.8 %. This study provides proof of concept for a new, low cost method of confirming HIV diagnosis in resource-limited settings. It has potential for use as a supplementary test in a confirmatory algorithm, whereby double positive RDT results undergo dilution testing, with positive results confirming HIV infection. Negative results require nucleic acid testing to rule out false negative results due to seroconversion or misclassification by the lower sensitivity dilution test. Further research is needed to determine if these results can be replicated in other settings. ClinicalTrials.gov, NCT01716299 .
Method for processing aqueous wastes
Pickett, John B.; Martin, Hollis L.; Langton, Christine A.; Harley, Willie W.
1993-01-01
A method for treating waste water such as that from an industrial processing facility comprising the separation of the waste water into a dilute waste stream and a concentrated waste stream. The concentrated waste stream is treated chemically to enhance precipitation and then allowed to separate into a sludge and a supernate. The supernate is skimmed or filtered from the sludge and blended with the dilute waste stream to form a second dilute waste stream. The sludge remaining is mixed with cementitious material, rinsed to dissolve soluble components, then pressed to remove excess water and dissolved solids before being allowed to cure. The dilute waste stream is also chemically treated to decompose carbonate complexes and metal ions and then mixed with cationic polymer to cause the precipitated solids to flocculate. Filtration of the flocculant removes sufficient solids to allow the waste water to be discharged to the surface of a stream. The filtered material is added to the sludge of the concentrated waste stream. The method is also applicable to the treatment and removal of soluble uranium from aqueous streams, such that the treated stream may be used as a potable water supply.
Methods and systems for micro transmissions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stalford, Harold L
2014-12-23
Methods and systems for micro transmissions for a micro machine may comprise an input shaft assembly coupled to a micro actuator, an output shaft assembly coupled to a micro shaft, and one or more power conversion elements operable to convert a first type of movement from the micro actuator into a second, disparate type of movement for the micro shaft.
Evaluation of the pulse-contour method of determining stroke volume in man.
NASA Technical Reports Server (NTRS)
Alderman, E. L.; Branzi, A.; Sanders, W.; Brown, B. W.; Harrison, D. C.
1972-01-01
The pulse-contour method for determining stroke volume has been employed as a continuous rapid method of monitoring the cardiovascular status of patients. Twenty-one patients with ischemic heart disease and 21 patients with mitral valve disease were subjected to a variety of hemodynamic interventions. The pulse-contour estimations, using three different formulas derived by Warner, Kouchoukos, and Herd, were compared with indicator-dilution outputs. A comparison of the results of the two methods for determining stroke volume yielded correlation coefficients ranging from 0.59 to 0.84. The better performing Warner formula yielded a coefficient of variation of about 20%. The type of hemodynamic interventions employed did not significantly affect the results using the pulse-contour method. Although the correlation of the pulse-contour and indicator-dilution stroke volumes is high, the coefficient of variation is such that small changes in stroke volume cannot be accurately assessed by the pulse-contour method. However, the simplicity and rapidity of this method compared to determination of cardiac output by Fick or indicator-dilution methods makes it a potentially useful adjunct for monitoring critically ill patients.
Vitamins D and A can be successfully measured by LC-MS/MS in cord blood diluted plasma.
Albarhani, Ali A; Collier, Fiona; Greaves, Ronda F; Ponsonby, Anne-Louise; Allen, Katrina J; Vuillermin, Peter J; Roche, Peter; Clarke, Michael W
2015-11-01
In widely used protocols for the collection and isolation of cord blood mononuclear cells, investigators are left with substantial volumes of diluted plasma which could be used for other measurements. The aim of this study was to ascertain the validity of umbilical cord blood (UCB) diluted plasma samples for vitamin D, A and E analysis compared to UCB serum samples. Twenty UCB matched samples of diluted plasma and serum were collected. The samples were analysed by two liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods on two separate occasions. The results of 25(OH)D3 obtained by the two laboratories demonstrated close agreement with a mean difference of 0.14nmol/L [95% confidence interval (95% CI), -6.8 to 7.1]. Both methods demonstrate close agreement for 25(OH)D3 in UCB serum versus diluted UCB plasma; mean difference 2.2nmol/L [95% CI, -9.5 to 13.9] and 4.1nmol/L [95% CI, -14.5 to 6.1] for the results from Lab A and Lab B, respectively. Vitamin A was quantified by Lab A in UCB serum and diluted UCB plasma; mean difference 0.07μmol/L [95% CI, -0.41 to 0.28]. Results of 25(OH)D3 epimer and vitamin E in the diluted UCB plasma were below the limit of quantification, and could not be compared with UCB serum. Diluted UCB plasma can be used for the quantification of retinol and 25(OH)D3 by LC-MS/MS. By contrast, quantification of 25(OH)D3 epimer and vitamin E in diluted UCB plasma is not supported by this study due to limitations in analytical sensitivity. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
An integrated miRNA functional screening and target validation method for organ morphogenesis.
Rebustini, Ivan T; Vlahos, Maryann; Packer, Trevor; Kukuruzinska, Maria A; Maas, Richard L
2016-03-16
The relative ease of identifying microRNAs and their increasing recognition as important regulators of organogenesis motivate the development of methods to efficiently assess microRNA function during organ morphogenesis. In this context, embryonic organ explants provide a reliable and reproducible system that recapitulates some of the important early morphogenetic processes during organ development. Here we present a method to target microRNA function in explanted mouse embryonic organs. Our method combines the use of peptide-based nanoparticles to transfect specific microRNA inhibitors or activators into embryonic organ explants, with a microRNA pulldown assay that allows direct identification of microRNA targets. This method provides effective assessment of microRNA function during organ morphogenesis, allows prioritization of multiple microRNAs in parallel for subsequent genetic approaches, and can be applied to a variety of embryonic organs.
Cao, Y; Griffith, J F; Dorevitch, S; Weisberg, S B
2012-07-01
Draft criteria for the optional use of qPCR for recreational water quality monitoring have been published in the United States. One concern is that inhibition of the qPCR assay can lead to false-negative results and potentially inadequate public health protection. We evaluate the effectiveness of strategies for minimizing the impact of inhibition. Five qPCR method permutations for measuring Enterococcus were challenged with 133 potentially inhibitory fresh and marine water samples. Serial dilutions were conducted to assess Enterococcus target assay inhibition, to which inhibition identified using four internal controls (IC) was compared. The frequency and magnitude of inhibition varied considerably among qPCR methods, with the permutation using an environmental master mix performing substantially better. Fivefold dilution was also effective at reducing inhibition in most samples (>78%). ICs were variable and somewhat ineffective, with 54-85% agreement between ICs and serial dilution. The current IC methods appear to not accurately predict Enterococcus inhibition and should be used with caution; fivefold dilution and the use of reagents designed for environmental sample analysis (i.e. more robust qPCR chemistry) may be preferable. Suitable approaches for defining, detecting and reducing inhibition will improve implementation of qPCR for water monitoring. © 2012 The Authors. Journal of Applied Microbiology © 2012 The Society for Applied Microbiology.
Aliahmadi, Atousa; Mirzajani, Fateme; Ghassempour, Alireza; Sonboli, Ali
2014-01-01
Background: Plants are considered as promising sources of new antibacterial agents as well as bioassay guided fractionation. Objectives: In the present work, the antibacterial properties, especially against methicillin-resistant Staphylococcus aureus (MRSA), of Bromus inermis inflorescence was studied, using the bioassay guided fractionation as well as the bio-autographic method. Materials and Methods: The plant organic extract was prepared via maceration in methanol, followed by the fractionation using n-hexane. The extracts were subjected for minimum inhibitory concentrations (MICs) against some human pathogenic bacteria via standard broth micro-dilution assay. Thereafter, a bio-autographical method was applied using the high performance thin layer chromatography (HPTLC) coupled with agar overlay assays for the primary characterization and identification of bioactive substance (s). Results: Through the bioassay guided fractionation method, the greatest antibacterial activities were related to the n-hexane extract. It was also revealed that the effective anti-MRSA agent of the assessed plant was a relatively polar substance with an MIC value of about 8 μg/mL against the tested MRSA strain (in comparison with the MIC value of 32 μg/mL for chloramphenicol). Conclusions: As a result of the full range UV-Vis scanning of the responsible band in the HPTLC experiments (200-700 nm), the flavonoid was the most imaginable natural compound. PMID:25741430
Siahi Shadbad, Mohammad Reza; Ghaderi, Faranak; Hatami, Leila; Monajjemzadeh, Farnaz
2016-12-01
In this study the stability of parenteral acyclovir (ACV) when diluted in dextrose (DEX) as large volume intravenous fluid preparation (LVIF) was evaluated and the possible Maillard reaction adducts were monitored in the recommended infusion time. Different physicochemical methods were used to evaluate the Maillard reaction of dextrose with ACV to track the reaction in real infusion condition. Other large volume intravenous fluids were checked regarding the diluted drug stability profile. Differential scanning calorimetry (DSC), Fourier transform infrared spectroscopy (FTIR), and mass data proved the reaction of glucose with dextrose. A Maillard-specific high performance liquid chromatography (HPLC) method was used to track the reaction in real infusion condition in vitro. The nucleophilic reaction occurred in diluted parenteral preparations of acyclovir in 5% dextrose solutions. The best diluent solution was also selected as sodium chloride and introduced based on drug stability and also its adsorption onto different infusion sets (PVC or non PVC) to provide an acceptable administration protocol in clinical practices. Although, the Maillard reaction was proved and successfully tracked in diluted solutions, and the level of drug loss when diluted in dextrose was reported to be between 0.27 up to 1.03% of the initial content. There was no drug adsorption to common infusion sets. The best diluent for parenteral acyclovir is sodium chloride large volume intravenous fluid.
Silvestro, Luigi; Tarcomnicu, Isabela; Dulea, Constanta; Attili, Nageswara Rao B N; Ciuca, Valentin; Peru, Dan; Rizea Savu, Simona
2013-10-01
Diosmin is a flavonoid often administered in the treatment of chronic venous insufficiency, hemorrhoids, and related affections. Diosmin is rapidly hydrolized in the intestine to its aglicone, diosmetin, which is further metabolized to conjugates. In this study, the development and validations of three new methods for the determination of diosmetin, free and after enzymatic deconjugation, and of its potential glucuronide metabolites, diosmetin-3-O-glucuronide, diosmetin-7-O-glucuronide, and diosmetin-3,7-O-glucuronide from human plasma and urine are presented. First, the quantification of diosmetin, free and after deconjugation, was carried out by high-performance liquid chromatography coupled with tandem mass spectrometry, on an Ascentis RP-Amide column (150 × 2.1 mm, 5 μm), in reversed-phase conditions, after enzymatic digestion. Then glucuronide metabolites from plasma were separated by micro-liquid chromatography coupled with tandem mass spectrometry on a HALO C18 (50 × 0.3 mm, 2.7 μm, 90 Å) column, after solid-phase extraction. Finally, glucuronides from urine were measured using a Discovery HSF5 (100 × 2.1 mm, 5 μm) column, after simple dilution with mobile phase. The methods were validated by assessing linearity, accuracy, precision, low limit of quantification, selectivity, extraction recovery, stability, and matrix effects; results in agreement with regulatory (Food and Drug Administration and European Medicines Agency) guidelines acceptance criteria were obtained in all cases. The methods were applied to a pharmacokinetic study with diosmin (450 mg orally administered tablets). The mean C max of diosmetin in plasma was 6,049.3 ± 5,548.6 pg/mL. A very good correlation between measured diosmetin and glucuronide metabolites concentrations was obtained. Diosmetin-3-O-glucuronide was identified as a major circulating metabolite of diosmetin in plasma and in urine, and this finding was confirmed by supplementary experiments with differential ion-mobility mass spectrometry.
Time effect and aliquot concentration in Streptococcus mutans elimination by plasma needle
NASA Astrophysics Data System (ADS)
García-Alcantara, E.; López-Callejas, R.; Peña-Eguiluz, R.; Lagunas-Bernabé, S.; Valencia-Alvarado, R.; Mercado-Cabrera, A.; Barocio, S. R.; Muñoz-Castro, A. E.; Rodríguez-Méndez, B. G.; de la Piedad-Beneitez, A.
2012-06-01
Atmospheric plasma needle systems are being intensively studied with a view to potential applications in medicine. The aim of this in vitro study is the improved elimination of Streptococcus Mutants (S. mutans) bacteria. A 5 ml volume of Luria-Bertani culture medium has been inoculated with a test bacterial population and incubated during 24 hours, followed by ten dilutions producing aliquots at 20, 50 and 100 micro l per dilution. Each aliquot is deposited on a paper filter and then exposed to a 2 W RF room pressure helium plasma needle discharge at a 1.5 l.p.m. rate for 1, 3, 5 or 7 minutes. Each sample paper is placed in a test tube, again containing Luria-Bertani fluid, in order to develop a new bacterium colony after a 24h incubation period. The plasma needle lethality has been evaluated from absorbance studies by means of a 6305 Jeway spectrophotometer at a 600 nm wavelength, indicating a clear correlation with exposure time. These studies validate the high disinfection efficacy of the plasma needle.
ERIC Educational Resources Information Center
Hill, Devon W.; And Others
1988-01-01
Describes a laboratory technique for quantitative analysis of caffeine by an isotopic dilution method for coupled gas chromatography-mass spectroscopy. Discusses caffeine analysis and experimental methodology. Lists sample caffeine concentrations found in common products. (MVL)
Dilute condition corrosion behavior of glass-ceramic waste form
Crum, Jarrod V.; Neeway, James J.; Riley, Brian J.; ...
2016-08-11
Borosilicate glass-ceramics are being developed to immobilize high-level waste generated by aqueous reprocessing into a stable waste form. The corrosion behavior of this multiphase waste form is expected to be complicated by multiple phases and crystal-glass interfaces. A modified single-pass flow-through test was performed on polished monolithic coupons at a neutral pH (25 °C) and 90 °C for 33 d. The measured glass corrosion rates by micro analysis in the samples ranged from 0.019 to 0.29 g m -2 d -1 at a flow rate per surface area = 1.73 × 10 -6 m s -1. The crystal phases (oxyapatitemore » and Ca-rich powellite) corroded below quantifiable rates, by micro analysis. While, Ba-rich powellite corroded considerably in O10 sample. The corrosion rates of C1 and its replicate C20 were elevated an order of magnitude by mechanical stresses at crystal-glass interface caused by thermal expansion mismatch during cooling and unique morphology (oxyapatite clustering).« less
Dilute condition corrosion behavior of glass-ceramic waste form
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crum, Jarrod V.; Neeway, James J.; Riley, Brian J.
Borosilicate glass-ceramics are being developed to immobilize high-level waste generated by aqueous reprocessing into a stable waste form. The corrosion behavior of this multiphase waste form is expected to be complicated by multiple phases and crystal-glass interfaces. A modified single-pass flow-through test was performed on polished monolithic coupons at a neutral pH (25 °C) and 90 °C for 33 d. The measured glass corrosion rates by micro analysis in the samples ranged from 0.019 to 0.29 g m -2 d -1 at a flow rate per surface area = 1.73 × 10 -6 m s -1. The crystal phases (oxyapatitemore » and Ca-rich powellite) corroded below quantifiable rates, by micro analysis. While, Ba-rich powellite corroded considerably in O10 sample. The corrosion rates of C1 and its replicate C20 were elevated an order of magnitude by mechanical stresses at crystal-glass interface caused by thermal expansion mismatch during cooling and unique morphology (oxyapatite clustering).« less
Microfluidic Serial Dilution Circuit
Paegel, Brian M.; Grover, William H.; Skelley, Alison M.; Mathies, Richard A.; Joyce, Gerald F.
2008-01-01
In vitro evolution of RNA molecules requires a method for executing many consecutive serial dilutions. To solve this problem, a microfluidic circuit has been fabricated in a three-layer glass-PDMS-glass device. The 400-nL serial dilution circuit contains five integrated membrane valves: three two-way valves arranged in a loop to drive cyclic mixing of the diluent and carryover, and two bus valves to control fluidic access to the circuit through input and output channels. By varying the valve placement in the circuit, carryover fractions from 0.04 to 0.2 were obtained. Each dilution process, which is comprised of a diluent flush cycle followed by a mixing cycle, is carried out with no pipeting, and a sample volume of 400 nL is sufficient for conducting an arbitrary number of serial dilutions. Mixing is precisely controlled by changing the cyclic pumping rate, with a minimum mixing time of 22 s. This microfluidic circuit is generally applicable for integrating automated serial dilution and sample preparation in almost any microfluidic architecture. PMID:17073422
Cremer, N E; Cossen, C K; Hanson, C V; Shell, G R
1982-01-01
Several methods for evaluating and reporting enzyme immunoassay (EIA) determinations of antibody to herpes simplex virus derived from one dilution of single serum samples were studied. An EIA ratio method for serological evidence of current infection from paired serum samples was also evaluated. Optical density (OD) of the reaction at a 1:100 serum dilution and estimated titers obtained by reference of the OD of the serum dilution to a standard curve were compared to the corresponding plotted EIA titer obtained by titration to endpoint. Neither the OD per se nor the estimated titer was completely predictive of the plotted titer (correlation coefficient [r] of 0.824 and 0.817, respectively), and they provided only a semiquantitative measurement of antibody concentration. For an antibody status report, however, OD would be sufficient if related to the cutoff value as an EIA index (OD of sample divided by cutoff OD for positive specimens). The OD of the EIA reaction at a single dilution (1:5) of cerebrospinal fluid, on the other hand, correlated quite well with the titer obtained by titration (r = 0.950). For serological diagnosis of current infection, the OD ratio of convalescence-phase/acute-phase sera was determined at several dilutions. A ratio of greater than or equal to 1.54 was calculated as a reliable index for a significant rise in antibody concentration and compatible with current infection. By determining the convalescent-phase/acute-phase serum ratio at two dilutions, 1:100 and 1:1,000, the EIA ratio method appeared to be a sensitive as or more sensitive than, complement fixation in diagnosing current infection. PMID:6284791
Effect of mixing method on the mixing degree during the preparation of triturations.
Nakamura, Hitoshi; Yanagihara, Yoshitsugu; Sekiguchi, Hiroko; Komada, Fusao; Kawabata, Haruno; Ohtani, Michiteru; Saitoh, Yukiya; Kariya, Satoru; Suzuki, Hiroshi; Uchino, Katsuyoshi; Iga, Tatsuji
2004-03-01
By using lactose colored with erythrocin, we investigated the effects of mixing methods on mixing degree during the preparation of trituration with a mortar and pestle. The extent of powder dilution was set to 4 to 64 fold in the experiments. We compared the results obtained by using two methods: (1) one-step mixing of powders after addition of diluents and (2) gradual mixing of powders after addition of diluents. As diluents, we used crystallized lactose and powdered lactose for the preparation of trituration. In the preparation of 64-fold trituration, an excellent degree of mixing was obtained, with CV values of less than 6.08%, for both preparation methods and for the two kinds of diluents. The mixing of two kinds of powders whose distributions of particle sizes were similar resulted in much better degree of mixing, with CV values of less than 3.0%. However, the concentration of principal agents in 64-fold trituration was reduced by 20% due to the adsorption of dye to the apparatus. Under conditions in which a much higher dilution rate and/or much better degree of dilution was required, it must be necessary to dilute powders with considering their physicality and to determine the concentrations of principal agents after the mixing.
A new serotyping method for Klebsiella species: development of the technique.
Riser, E; Noone, P; Poulton, T A
1976-01-01
A new serotyping method for Klebsiella species using indirect immunofluorescence is described. Nonspecific fluorescence has been minimized by carrying out the capsular antigen-antibody reaction at pH 9.0. Commercial antisera have been tested with the 72 antigenic types of Klebsiella, and appropriate dilutions of each pool and specific antisera have been proposed for use in routine typing. Dilutions were chosen to allow strong fluorescence with each type and its specific antiserum and minimal fluorescence with cross reacting antisera. Where the pool antisera gave a weak reaction for one or more of the component types, it is recommended that the specific antisera for these types be added to the pool dilution. The few remaining cross reactions, with the pool and specific antisera in test dilution, are listed in a table. The unique cross reacting patterns of particular types have been found to be useful in identification. Typing Klebsiella by the fluorescent antibody technique is easy to perform and interpret; the results are reproducible, and it is less expensive than the existing capsular swelling method as it is more sensitive and requires less concentrated antisera. This new method of typing should facilitate detailed epidemiological studies of the mode of transmission of Klebsiella species in hospitals and thus allow more effective infection control measures to be instituted. Images PMID:777042
Alhassan, Andy; Govind, Yadav; Tam, Nguyen Thanh; Thekisoe, Oriel M M; Yokoyama, Naoaki; Inoue, Noboru; Igarashi, Ikuo
2007-04-01
The sensitivity of LAMP, PCR and in vitro culture methods for the detection of Theileria equi and Babesia caballi was evaluated using tenfold serially diluted culture parasites. On day 1 post-culture, both T. equi and B. caballi parasites could only be observed at 1% parasite dilution from the in vitro culture method, whereas LAMP could detect up to 1 x 10(-3)% of both T. equi and B. caballi parasite dilutions, whilst PCR could detect 1 x 10(-3)% T. equi and 1 x 10(-1)% B. caballi parasite dilutions. On day 7 post-culture, the detection limit for T. equi and B. caballi in the in vitro culture increased up to 1 x 10(-6)%, whereas LAMP detection limit increased to 1 x 10(-10)% for both parasites, whilst the PCR detection limit increased to 1 x 10(-10)% and 1 x 10(-6)% for T. equi and B. caballi, respectively. Furthermore, LAMP and PCR amplified the T. equi DNA extracted from the organs of an experimentally infected horse. This study further validates LAMP as an alternative molecular diagnostic tool, which can be used in the diagnosis of early infections of equine piroplasmosis and together with PCR can also be used as supplementary methods during post-mortems.
Fast and accurate calculation of dilute quantum gas using Uehling–Uhlenbeck model equation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yano, Ryosuke, E-mail: ryosuke.yano@tokiorisk.co.jp
The Uehling–Uhlenbeck (U–U) model equation is studied for the fast and accurate calculation of a dilute quantum gas. In particular, the direct simulation Monte Carlo (DSMC) method is used to solve the U–U model equation. DSMC analysis based on the U–U model equation is expected to enable the thermalization to be accurately obtained using a small number of sample particles and the dilute quantum gas dynamics to be calculated in a practical time. Finally, the applicability of DSMC analysis based on the U–U model equation to the fast and accurate calculation of a dilute quantum gas is confirmed by calculatingmore » the viscosity coefficient of a Bose gas on the basis of the Green–Kubo expression and the shock layer of a dilute Bose gas around a cylinder.« less
de Jong, Jeroen; Schoemann, Véronique; Lannuzel, Delphine; Tison, Jean-Louis; Mattielli, Nadine
2008-08-15
In the present paper we describe a robust and simple method to measure dissolved iron (DFe) concentrations in seawater down to <0.1 nmol L(-1) level, by isotope dilution multiple collector inductively coupled plasma mass spectrometry (ID-MC-ICP-MS) using a (54)Fe spike and measuring the (57)Fe/(54)Fe ratio. The method provides for a pre-concentration step (100:1) by micro-columns filled with the resin NTA Superflow of 50 mL seawater samples acidified to pH 1.9. NTA Superflow is demonstrated to quantitatively extract Fe from acidified seawater samples at this pH. Blanks are kept low (grand mean 0.045+/-0.020 nmol L(-1), n=21, 3 x S.D. limit of detection per session 0.020-0.069 nmol L(-1) range), as no buffer is required to adjust the sample pH for optimal extraction, and no other reagents are needed than ultrapure nitric acid, 12 mM H(2)O(2), and acidified (pH 1.9) ultra-high purity (UHP) water. We measured SAFe (sampling and analysis of Fe) reference seawater samples Surface-1 (0.097+/-0.043 nmol L(-1)) and Deep-2 (0.91+/-0.17 nmol L(-1)) and obtained results that were in excellent agreement with their DFe consensus values: 0.118+/-0.028 nmol L(-1) (n=7) for Surface-1 and 0.932+/-0.059 nmol L(-1) (n=9) for Deep-2. We also present a vertical DFe profile from the western Weddell Sea collected during the Ice Station Polarstern (ISPOL) ice drift experiment (ANT XXII-2, RV Polarstern) in November 2004-January 2005. The profile shows near-surface DFe concentrations of approximately 0.6 nmol L(-1) and bottom water enrichment up to 23 nmol L(-1) DFe.
Cartagena, Andrés Felipe; Esmerino, Luís Antonio; Polak-Junior, Rogerio; Olivieri Parreiras, Sibelli; Domingos Michél, Milton; Farago, Paulo Vitor; Campanha, Nara Hellen
2017-02-01
The purpose of this study was to develop a new oral drug delivery system by incorporating polymeric miconazole nitrate (MN) microparticles on an experimental antifungal denture adhesive (DA). Spray drying Eudragit L-100 (E) and Gantrez MS-955 (G) MN-microparticles were incorporated in DA. DAE1, DAG1, DAEG1, DAE2, DAG2, DAEG2 groups were obtained from the combination of polymers used in MN-microparticles (E, G and EG) and concentration of MN into DA (1, for 1% and 2, for 2%). DA with 2% pure MN (DAM) and DA without microparticles or drug (DACT) were both control groups. All groups were evaluated to determine microbiological assay, adhesive force and toxicity. Minimum inhibitory concentration (MIC) against Candida albicans was performed by broth micro-dilution and agar dilution methods in extract of DAs and conventional gel form (Daktarin ® ). Adhesive load testing was made between acrylic resin samples on a universal testing machine after immersion in water. The toxicity of several dilutions of DAs was performed with Artemia salina bioassay after 24 and 48h. Data of adhesive force were evaluated with two-way ANOVA and Bonferroni tests (α=0.05). The concentration required to kill 50% (LC50) was determined using the Provit analysis. DA with polymeric microparticles and pure drug presented MIC between 1.25-5μg/mL similar to MIC values of DAM. DAEG2, DAEG1, DAG20 showed the most actives against C. albicans. The best adhesive properties were exhibited by DAEG2, consisting of high initial adhesive force which was maintained for up to 6h. The extracts of all DA presented low or not toxicity at 24 and 48h. DA containing 2% of MN loaded in microparticles made by Gantrez MS-955 alone or combined with Eudragit L-100 produce effective antifungal activity, good adhesive force, and no toxicity effect being a promising therapeutics for removable denture wearers affected by denture stomatitis. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Reusable chelating resins concentrate metal ions from highly dilute solutions
NASA Technical Reports Server (NTRS)
Bauman, A. J.; Weetal, H. H.; Weliky, N.
1966-01-01
Column chromatographic method uses new metal chelating resins for recovering heavy-metal ions from highly dilute solutions. The absorbed heavy-metal cations may be removed from the chelating resins by acid or base washes. The resins are reusable after the washes are completed.
Study the Effect of SiO2 Based Flux on Dilution in Submerged Arc Welding
NASA Astrophysics Data System (ADS)
kumar, Aditya; Maheshwari, Sachin
2017-08-01
This paper highlights the method for prediction of dilution in submerged arc welding (SAW). The most important factors of weld bead geometry are governed by the weld dilution which controls the chemical and mechanical properties. Submerged arc welding process is used generally due to its very easy control of process variables, good penetration, high weld quality, and smooth finish. Machining parameters, with suitable weld quality can be achieved with the different composition of the flux in the weld. In the present study Si02-Al2O3-CaO flux system was used. In SiO2 based flux NiO, MnO, MgO were mixed in various proportions. The paper investigates the relationship between the process parameters like voltage, % of flux constituents and dilution with the help of Taguchi’s method. The experiments were designed according to Taguchi L9 orthogonal array, while varying the voltage at two different levels in addition to alloying elements. Then the optimal results conditions were verified by confirmatory experiments.
Breakdown of cell wall nanostructure in dilute acid pretreated biomass.
Pingali, Sai Venkatesh; Urban, Volker S; Heller, William T; McGaughey, Joseph; O'Neill, Hugh; Foston, Marcus; Myles, Dean A; Ragauskas, Arthur; Evans, Barbara R
2010-09-13
The generation of bioethanol from lignocellulosic biomass holds great promise for renewable and clean energy production. A better understanding of the complex mechanisms of lignocellulose breakdown during various pretreatment methods is needed to realize this potential in a cost and energy efficient way. Here we use small-angle neutron scattering (SANS) to characterize morphological changes in switchgrass lignocellulose across molecular to submicrometer length scales resulting from the industrially relevant dilute acid pretreatment method. Our results demonstrate that dilute acid pretreatment increases the cross-sectional radius of the crystalline cellulose fibril. This change is accompanied by removal of hemicellulose and the formation of R(g) ∼ 135 A lignin aggregates. The structural signature of smooth cell wall surfaces is observed at length scales larger than 1000 A, and it remains remarkably invariable during pretreatment. This study elucidates the interplay of the different biomolecular components in the breakdown process of switchgrass by dilute acid pretreatment. The results are important for the development of efficient strategies of biomass to biofuel conversion.
Infinitely dilute partial molar properties of proteins from computer simulation.
Ploetz, Elizabeth A; Smith, Paul E
2014-11-13
A detailed understanding of temperature and pressure effects on an infinitely dilute protein's conformational equilibrium requires knowledge of the corresponding infinitely dilute partial molar properties. Established molecular dynamics methodologies generally have not provided a way to calculate these properties without either a loss of thermodynamic rigor, the introduction of nonunique parameters, or a loss of information about which solute conformations specifically contributed to the output values. Here we implement a simple method that is thermodynamically rigorous and possesses none of the above disadvantages, and we report on the method's feasibility and computational demands. We calculate infinitely dilute partial molar properties for two proteins and attempt to distinguish the thermodynamic differences between a native and a denatured conformation of a designed miniprotein. We conclude that simple ensemble average properties can be calculated with very reasonable amounts of computational power. In contrast, properties corresponding to fluctuating quantities are computationally demanding to calculate precisely, although they can be obtained more easily by following the temperature and/or pressure dependence of the corresponding ensemble averages.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harrahy, E.A.; Clements, W.H.
1997-02-01
This research investigated toxicity and bioaccumulation of a mixture of Cd, Cu, Pb, and Zn in Chironomus tentans in synthetic sediment, and compared predicted to measured steady-state bioaccumulation factors (BAFs). In a toxicity test, C. tentans were exposed to various dilutions of a base concentration (1.0 X) of a mixture of the four metals (5 {micro}g/g Cd. 10 {micro}g/g Cu. 70 {micro}g/g Pb, and 300 {micro}g/g Zn) in synthetic sediment. Mortality ranged from 17 to 100%. To measure bioaccumulation of the metals, C. tentans were exposed to 0.35 X the base concentration for a period of up to 14 dmore » in two uptake tests. Bioaccumulation of all four metals increased over the 14-d uptake phases. Concentrations of metals in chironomids were significantly correlated with exposure time in the uptake phases. Only concentrations of copper approached background levels after 7 d depuration. Uptake rate coefficients and elimination rate constants were determined for each metal. Bioaccumulation factors were highest for Cd and lowest for Pb. With the exception of Pb, steady-state BAFs were within a factor of about two of those calculated using the first-order kinetic model. The high BAFs calculated may indicate greater bioavailability in synthetic sediment. Studies comparing toxicity and bioaccumulation of natural and synthetic sediments are necessary before the use of synthetic sediments is widely adopted.« less
Method for processing aqueous wastes
Pickett, J.B.; Martin, H.L.; Langton, C.A.; Harley, W.W.
1993-12-28
A method is presented for treating waste water such as that from an industrial processing facility comprising the separation of the waste water into a dilute waste stream and a concentrated waste stream. The concentrated waste stream is treated chemically to enhance precipitation and then allowed to separate into a sludge and a supernate. The supernate is skimmed or filtered from the sludge and blended with the dilute waste stream to form a second dilute waste stream. The sludge remaining is mixed with cementitious material, rinsed to dissolve soluble components, then pressed to remove excess water and dissolved solids before being allowed to cure. The dilute waste stream is also chemically treated to decompose carbonate complexes and metal ions and then mixed with cationic polymer to cause the precipitated solids to flocculate. Filtration of the flocculant removes sufficient solids to allow the waste water to be discharged to the surface of a stream. The filtered material is added to the sludge of the concentrated waste stream. The method is also applicable to the treatment and removal of soluble uranium from aqueous streams, such that the treated stream may be used as a potable water supply. 4 figures.
In situ formation of phosphate barriers in soil
Moore, Robert C.
2002-01-01
Reactive barriers and methods for making reactive barriers in situ in soil for sequestering soil ontaminants including actinides and heavy metals. The barrier includes phosphate, and techniques are disclosed for forming specifically apatite barriers. The method includes injecting dilute reagents into soil in proximity to a contamination plume or source such as a waste drum to achieve complete or partial encapsulation of the waste. Controlled temperature and pH facilitates rapid formation of apatite, for example, where dilute aqueous calcium chloride and dilute aqueous sodium phosphate are the selected reagents. Mixing of reagents to form precipitate is mediated and enhanced through movement of reagents in soil as a result of phenomena including capillary action, movement of groundwater, soil washing and reagent injection pressure.
Micro-zooplankton grazing as a means of fecal bacteria removal in stormwater BMPs.
Burtchett, Jade M; Mallin, Michael A; Cahoon, Lawrence B
2017-06-01
A priority for environmental managers is control of stormwater runoff pollution, especially fecal microbial pollution. This research was designed to determine if fecal bacterial grazing by micro-zooplankton is a significant control on fecal bacteria in aquatic best management practices (BMPs); if grazing differs between a wet detention pond and a constructed wetland; and if environmental factors enhance grazing. Both 3-day grazing tests and 24-h dilution assays were used to determine grazing differences between the two types of BMP. Micro-zooplankton grazing was a stronger bacteria removal mechanism in stormwater wetlands rich in aquatic vegetation compared to a standard wet detention pond, although grazing was important in detention ponds as well. Our experiments indicated that the majority of grazers that fed on fecal bacteria were <20 μm in size. Grazing rates were positively correlated with fecal coliform abundance and increased water temperatures. Enumeration of grazers demonstrated that protozoans were significantly more abundant among wetland vegetation than in open water, and open wetland waters contained more flagellates and dinoflagellates than open wet detention pond waters. Grazing on fecal bacteria in BMPs is enhanced by aquatic vegetation, and grazing in aquatic BMPs in warmer climates should be greater than in cooler climates.
Voskoboev, Nikolay V; Cambern, Sarah J; Hanley, Matthew M; Giesen, Callen D; Schilling, Jason J; Jannetto, Paul J; Lieske, John C; Block, Darci R
2015-11-01
Validation of tests performed on body fluids other than blood or urine can be challenging due to the lack of a reference method to confirm accuracy. The aim of this study was to evaluate alternate assessments of accuracy that laboratories can rely on to validate body fluid tests in the absence of a reference method using the example of sodium (Na(+)), potassium (K(+)), and magnesium (Mg(2+)) testing in stool fluid. Validations of fecal Na(+), K(+), and Mg(2+) were performed on the Roche cobas 6000 c501 (Roche Diagnostics) using residual stool specimens submitted for clinical testing. Spiked recovery, mixing studies, and serial dilutions were performed and % recovery of each analyte was calculated to assess accuracy. Results were confirmed by comparison to a reference method (ICP-OES, PerkinElmer). Mean recoveries for fecal electrolytes were Na(+) upon spiking=92%, mixing=104%, and dilution=105%; K(+) upon spiking=94%, mixing=96%, and dilution=100%; and Mg(2+) upon spiking=93%, mixing=98%, and dilution=100%. When autoanalyzer results were compared to reference ICP-OES results, Na(+) had a slope=0.94, intercept=4.1, and R(2)=0.99; K(+) had a slope=0.99, intercept=0.7, and R(2)=0.99; and Mg(2+) had a slope=0.91, intercept=-4.6, and R(2)=0.91. Calculated osmotic gap using both methods were highly correlated with slope=0.95, intercept=4.5, and R(2)=0.97. Acid pretreatment increased magnesium recovery from a subset of clinical specimens. A combination of mixing, spiking, and dilution recovery experiments are an acceptable surrogate for assessing accuracy in body fluid validations in the absence of a reference method. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Fabresse, Nicolas; Allard, Julien; Sardaby, Marine; Thompson, Adrian; Clutton, R Eddie; Eddleston, Michael; Alvarez, Jean-Claude
2017-08-15
Clinical evaluation of a colchicine specific antigen-binding fragment (Fab) in order to treat colchicine poisoning required the development of an accurate method allowing quantification of free and Fab-bound colchicine in plasma and urine, and free colchicine in tissues, to measure colchicine redistribution after Fab administration. Three methods have been developed for this purpose, and validated in plasma, urine and liver: total colchicine was determined after denaturation of Fab by dilution in water and heating; free colchicine was separated from Fab-bound colchicine by filtration with 30KDa micro-filters; tissues were homogenized in a tissue mixer. Deuterated colchicine was used as internal standard. Samples were extracted by liquid-liquid extraction and analyzed with a LC-MS/MS. LOQ were 0.5ng/mL in plasma and urine for free and total colchicine and 5pg/mg in tissues. The methods were linear in the 0.5-100ng/mL range in plasma and urine, and 5-300pg/mg in tissues with determination coefficients>0.99. Precision and accuracy of QC samples presented a CV<9.4%. The methods require only 200μL of sample and allow a high throughput due to short analytical run (2min). These methods were successfully applied to a pig intoxicated with colchicine and treated with colchicine specific Fab fragments. Copyright © 2017 Elsevier B.V. All rights reserved.
Reverse isotope dilution method for determining benzene and metabolites in tissues
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bechtold, W.E.; Sabourin, P.J.; Henderson, R.F.
1988-07-01
A method utilizing reverse isotope dilution for the analysis of benzene and its organic soluble metabolites in tissues of rats and mice is presented. Tissues from rats and mice that had been exposed to radiolabeled benzene were extracted with ethyl acetate containing known, excess quantities of unlabeled benzene and metabolites. Butylated hydroxytoluene was added as an antioxidant. The ethyl acetate extracts were analyzed with semipreparative reversed-phase HPLC. Isolated peaks were collected and analyzed for radioactivity (by liquid scintillation spectrometry) and for mass (by UV absorption). The total amount of each compound present was calculated from the mass dilution of themore » radiolabeled isotope. This method has the advantages of high sensitivity, because of the high specific activity of benzene, and relative stability of the analyses, because of the addition of large amounts of unlabeled carrier analogue.« less
Raeisi, Javad; Saifi, Mahnaz; Pourshafie, Mohammad Reza; Asadi Karam, Mohammad Reza; Mohajerani, Hamid Reza
2015-01-01
Background: Methicillin-Resistant Staphylococcus aureus (MRSA) is a major pathogen in the hospital and community settings. Rapid methods to diagnose S. aureus infections are sought by many researchers worldwide. The current study aimed to utilize a phenotypic method of turanose fermentation to identify methicillin-susceptible and resistant S. aureus. Objectives: The current study aimed to assay the turanose metabolism at different dilutions as a rapid phenotypic method to identify MRSA isolates. Materials and Methods: A total of 150 Staphylococcus isolates were collected from Tehran health centers. Staphylococcus aureus isolates were identified based on cultural characteristics, biochemical reactions and positive tube coagulase test. Methicillin resistance was determined by the disk diffusion method. The Polymerase Chain Reaction amplification was used to detect the mecA gene in MRSA isolates. All the methicillin-resistant and susceptible isolates were evaluated for turanose metabolism with 1%, 0.7% and 0.5% dilutions using the microplate method. Results: Out of the 150 staphylococcal isolates, 80 were identified as S. aureus. Among which 40 (50%) of the isolates were MRSA. The mecA gene was present in all S. aureus isolates resistant to methicillin. A considerable difference was also observed between susceptible and resistant isolates of S. aureus at a 0.7% dilution of turanose. Conclusions: Since it is highly important to rapidly detect MRSA isolates, especially in nosocomial infections, phenotypic methods may certainly be useful for this purpose. Resistance to methicillin in S. aureus shows a substantially increased ability in turanose metabolism. It is concluded that fermentation of turanose at 0.7% dilution could be a rapid detection method for primary screening of MRSA isolates. PMID:26495105
NASA Astrophysics Data System (ADS)
Soriano, Allan N.; Adamos, Kristoni G.; Bonifacio, Pauline B.; Adornado, Adonis P.; Bungay, Vergel C.; Vairavan, Rajendaran
2017-11-01
The fate of antibiotics entering the environment raised concerns on the possible effect of antimicrobial resistance bacteria. Prediction of the fate and transport of these particles are needed to be determined, significantly the diffusion coefficient of antibiotic in water at infinite dilution. A systematic determination of diffusion coefficient of antibiotic in water at infinite dilution of five different kinds of livestock antibiotics namely: Amtyl, Ciprotyl, Doxylak Forte, Trisullak, and Vetracin Gold in the 293.15 to 313.15 K temperature range are reported through the use of the method involving the electrolytic conductivity measurements. A continuous stirred tank reactor is utilized to measure the electrolytic conductivities of the considered systems. These conductivities are correlated by using the Nernst-Haskell equation to determine the infinite dilution diffusion coefficient. Determined diffusion coefficients are based on the assumption that in dilute solution, these antibiotics behave as strong electrolyte from which H+ cation dissociate from the antibiotic's anion.
A micro-vibration generated method for testing the imaging quality on ground of space remote sensing
NASA Astrophysics Data System (ADS)
Gu, Yingying; Wang, Li; Wu, Qingwen
2018-03-01
In this paper, a novel method is proposed, which can simulate satellite platform micro-vibration and test the impact of satellite micro-vibration on imaging quality of space optical remote sensor on ground. The method can generate micro-vibration of satellite platform in orbit from vibrational degrees of freedom, spectrum, magnitude, and coupling path. Experiment results show that the relative error of acceleration control is within 7%, in frequencies from 7Hz to 40Hz. Utilizing this method, the system level test about the micro-vibration impact on imaging quality of space optical remote sensor can be realized. This method will have an important applications in testing micro-vibration tolerance margin of optical remote sensor, verifying vibration isolation and suppression performance of optical remote sensor, exploring the principle of micro-vibration impact on imaging quality of optical remote sensor.
NASA Technical Reports Server (NTRS)
Alexander, Donita; DePaola, Angelo; Young, Ronald B.
1998-01-01
The disease cholera, caused by Vibrio cholerae, has been associated with consumption of contaminated seafood, including raw oysters. Detection of V. cholerae in foods typically involves blending the oysters, diluting the homogenate in alkaline peptone water (APW), overnight enrichment, and isolation on selective agar. Unfortunately, the oyster homogenate must be diluted to large volumes because lower dilutions inhibit the growth of V. cholerae. The goals of this study were to develop an alternative to large dilutions and to evaluate the basis for the inhibition observed in lower dilutions of oyster homogenates. Centrifugation of oyster homogenates at 10,000 x g for 15 min, followed by enrichment of the resulting pellet in APW, was found to eliminate the inhibition of V. cholerae growth. Inhibition appears not to be due to competing microflora but to a component(s) released when V. cholerae grows in the presence of oyster homogenate. The inhibitory component(s) kills the V. cholerae after the cell concentration reaches > 10(exp 8) cells/mL, rather than initially preventing their growth. The pH also declines from 8.0 to 5.5 during this period; however, the pH decline by itself appears not to cause V. cholerae death. Seven strains of V. cholerae (01 and non-01) and two strains of V. vulnificus were susceptible to the inhibitory agent(s). However, other Vibrio and non-Vibrio species tested were not inhibited by the oyster homogenates. Based on digestion of oyster homogenates with pronase, trypsin and lipase, the inhibitory reaction involves a protein(s). In a preliminary trial with oyster homogenate seeded with 1 cfu/g of V. cholerae, the modified centrifugation technique detected a slightly higher percentage of samples at a 1:10 dilution than the standard FDA Bacteriological Analytical Method (BAM) detected in uncentrifuged oyster homogenate at a 1:100 dilution. V. cholerae in seeded samples could also be detected more frequently by the modified centrifugation method than by PCR at a 1:10 dilution.
NASA Astrophysics Data System (ADS)
Paillet, Frederick
2012-08-01
A simple mass-balance code allows effective modeling of conventional fluid column resistivity logs in dilution tests involving column replacement with either distilled water or dilute brine. Modeling a series of column profiles where the inflowing formation water introduces water quality interfaces propagating along the borehole gives effective estimates of the rate of borehole flow. Application of the dilution model yields estimates of borehole flow rates that agree with measurements made with the heat-pulse flowmeter under ambient and pumping conditions. Model dilution experiments are used to demonstrate how dilution logging can extend the range of borehole flow measurement at least an order of magnitude beyond that achieved with flowmeters. However, dilution logging has the same dynamic range limitation encountered with flowmeters because it is difficult to detect and characterize flow zones that contribute a small fraction of total flow when that contribution is superimposed on a larger flow. When the smaller contribution is located below the primary zone, ambient downflow may disguise the zone if pumping is not strong enough to reverse the outflow. This situation can be addressed by increased pumping. But this is likely to make the moveout of water quality interfaces too fast to measure in the upper part of the borehole, so that a combination of flowmeter and dilution method may be more appropriate. Numerical experiments show that the expected weak horizontal flow across the borehole at conductive zones would be almost impossible to recognize if any ambient vertical flow is present. In situations where natural water quality differences occur such as flowing boreholes or injection experiments, the simple mass-balance code can be used to quantitatively model the evolution of fluid column logs. Otherwise, dilution experiments can be combined with high-resolution flowmeter profiles to obtain results not attainable using either method alone.
Avijgan, M; Mahboubi, M; Moheb Nasab, M; Ahmadi Nia, E; Yousefi, H
2014-06-01
Candida albicans is one of the main causes of vaginitis, especially in women with recurrent episodes. The appearance of drug resistant C. albicans and adverse effects of chemical agents have raised interest in Echinophora platyloba as one of four native species in Traditional Persian-Iranian medicine. This study evaluates the antifungal activity of ethanolic extract from dried aerial parts of E. platyloba against 27 clinical isolates of C. albicans from women suffering chronic recurrent vaginitis by micro-broth dilution assay. The synergistic effect of azole drugs and E. platyloba ethanolic extract were also determined by disc diffusion method after determining the MIC90. The results of this study showed a potent synergistic effect of E. platyloba ethanolic extract and itraconazole (P<0.01) and fluconazole (P<0.001) but an antagonistic effect between E. platyloba ethanolic extract and clotrimazole and miconazole against clinical isolates of C. albicans. These results must be confirmed by clinical application and by further clinical studies. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Large-scale production of PMMA/SWCNT composites based on SWCNT modified with PMMA.
Fraser, Robin Anderson; Stoeffler, Karen; Ashrafi, Behnam; Zhang, Yunfa; Simard, Benoit
2012-04-01
In this work, a two-step method consisting of in situ polymerization of polymethyl methacrylate (PMMA) in the presence of single-walled carbon nanotubes (SWCNT), followed by the redispersion of the resulting compound in dimethylformamide (DMF), was used to fabricate SWCNT modified with PMMA (SWCNT-PMMA). Raman spectroscopy revealed that PMMA was merely wrapped around the SWCNT when raw SWCNT or purified SWCNT were used as the starting material. However, PMMA was covalently bonded to SWCNT when acid treated SWCNT (SWCNT-COOH) was used as the starting material. SWCNT-PMMA compounds were further diluted in pure PMMA by conventional melt compounding at large scale (several kilograms) to obtain transparent composites containing 0.09 wt % SWCNT. The micro- and nano-dispersion of the SWCNT in the composites were analyzed using scanning electron microscopy (SEM) and transmission electron microscopy (TEM). The thermal and mechanical properties of the composites were determined by thermal gravimetric analysis (TGA), differential scanning calorimetry (DSC), tensile testing, and Charpy impact testing. At the the low SWCNT loading studied, the tensile properties remain unchanged, whereas the impact strength improves by 20%.
NASA Astrophysics Data System (ADS)
Kang, Yura; Yoo, Chang-Hyoung; Nam, Deok-Hui; Lee, Myung-Hyun; Seo, Won-Seon; Hong, Suklyun; Jeong, Seong-Min
2018-03-01
In this study, we thermodynamically reviewed the suitable growth process conditions of α-SiC in the Si-C-H system using tetramethylsilane (TMS) and in the Si-C-H-Cl system using methyltrichlorosilane (MTS). In the Si-C-H-Cl system, pure solid SiC was obtained at high temperatures under a larger range of hydrogen dilution ratios than that tolerated in the Si-C-H system. X-ray diffraction and micro-Raman analysis of the products obtained at 1900, 2000, and 2100 °C showed that the α-SiC becomes more dominant with increasing temperature in the Si-C-H-Cl system. While TMS was unsuitable for high temperature processing due to its high C/Si ratio, MTS was found to be appropriate for growing α-SiC crystals at high temperatures under a range of conditions. These results indicate that a novel method to grow α-SiC single crystals through HTCVD using MTS as a precursor could be established.
Graphene sheets modified with polyindole for electro-chemical detection of dopamine.
Kumar, Ashish; Prakash, Rajiv
2014-03-01
Oxidized polyindole is coated over graphene surface by in-situ chemical oxidation method in dilute hydrochloric acid solution. Morphology of graphene modified with oxidized polyindole is investigated by scanning electron microscope. The interaction of graphene to polyindole is observed by Raman spectroscopy. The introduction of carboxylate functionality is observed in graphene due to pyrolysis. The association of this functionality with indole monomer and their interactive behaviour led to formation of uniform polyindole over graphene surface in presence of oxidizing agent. Our chemical synthesis results not only formation of uniform polymer thin layer over the graphene sheets but also enhances various properties and processibility of the graphene. Negative surface charge on the composite material is observed at acidic pH, which shows potential for accumulation of positively charged species in the solution. Further it is explored for electro-catalytic and sensing applications and shows cation permselective behavior of dopamine hydrochloride. It is demonstrated by differential pulse voltammetric technique in dopamine concentration range from 10 microM to 1 mM (in presence of 1 mM ascorbic acid).
Antifungal activity of multifunctional Fe 3O 4-Ag nanocolloids
NASA Astrophysics Data System (ADS)
Chudasama, Bhupendra; Vala, Anjana K.; Andhariya, Nidhi; Upadhyay, R. V.; Mehta, R. V.
2011-05-01
In recent years, rapid increase has been observed in the population of microbes that are resistant to conventionally used antibiotics. Antifungal drug therapy is no exception and now resistance to many of the antifungal agents in use has emerged. Therefore, there is an inevitable and urgent medical need for antibiotics with novel antimicrobial mechanisms. Aspergillus glaucus is the potential cause of fatal brain infections and hypersensitivity pneumonitis in immunocompromised patients and leads to death despite aggressive multidrug antifungal therapy. In the present article, we describe the antifungal activity of multifunctional core-shell Fe 3O 4-Ag nanocolloids against A. glaucus isolates. Controlled experiments are also carried out with Ag nanocolloids in order to understand the role of core (Fe 3O 4) in the antifungal action. The minimum inhibitory concentration (MIC) of nanocolloids is determined by the micro-dilution method. MIC of A. glaucus is 2000 μg/mL. The result is quite promising and requires further investigations in order to develop a treatment methodology against this death causing fungus in immunocompromised patients.
Katoch, Meenu; Singh, Gurpreet; Sharma, Sadhna; Gupta, Nidhi; Sangwan, Payare Lal; Saxena, Ajit Kumar
2014-02-11
Endophytes, which reside in plant tissues, have the potential to produce novel metabolites with immense benefits for health industry. Cytotoxic and antimicrobial activities of endophytic fungi isolated from Bacopa monnieri (L.) Pennell were investigated. Endophytic fungi were isolated from the Bacopa monnieri. Extracts from liquid cultures were tested for cytotoxicity against a number of cancer cell lines using the MTT assay. Antimicrobial activity was determined using the micro dilution method. 22% of the examined extracts showed potent (IC50 of <20 μg/ml) cytotoxic activity against HCT-116 cell line. 5.5%, 11%, 11% of the extracts were found to be cytotoxic for MCF-7, PC-3, and A-549 cell lines respectively. 33% extracts displayed antimicrobial activity against at least one test organism with MIC value 10-100 μg/ml. The isolate B9_Pink showed the most potent cytotoxic activity for all the cell lines examined and maximum antimicrobial activity against the four pathogens examined which was followed by B19. Results indicated the potential for production of bioactive agents from endophytes of Bacopa monnieri.
NASA Astrophysics Data System (ADS)
Nguyen, Minh-Hang; Chu, Thi-Xuan; Nguyen, Long; Nguyen, Hai-Binh; Lee, Chun-Wei; Tseng, Fan-Gang; Chen, Te-Chang; Lee, Ming-Chang
2016-11-01
Fabrication of three-dimensional (3D) SU-8 (an epoxy-based negative photoresist from MicroChem) prisms as low-loss couplers for interconnection between optical components, particularly optical fibers and silicon-on-isolator waveguides (SOI WGs), which have mismatched mode sizes, has been investigated. With an interfacial structure formed by a 3D SU-8 prism partly overlaying an SOI WG end with a portion of buried oxide (BOX) removed under the interface, low-loss coupling is ensured and the transmission efficiency can reach 70%. To fabricate these 3D SU-8 prisms, a simple method with two photolithography steps was used for SU-8 hinges and CYTOP (an amorphous fluoropolymer from AGC Chemicals) prism windows, with mild soft and hard bakes, to define the prism profiles with diluted SU-8 filled in the CYTOP prism windows. A buffered oxide etchant is used to remove BOX parts under the interfaces. Some of the fabricated structures were tested, demonstrating the contribution of overlaying SU-8 prisms to the transmission efficiency of optical interconnections between fibers and SOI WGs.
Westfall, Megan E; Demcovitz, Dina L; Plourdé, Daisy R; Rotstein, David S; Brown, Daniel R
2006-06-01
Mycoplasma iguanae proposed species nova was isolated from vertebral abscesses of two feral iguanas (Iguana iguana) from Florida. Three strains were evaluated for sensitivity to a variety of antibiotics. The minimum inhibitory concentrations for M. iguanae, assessed by broth dilution methods, of clindamycin, doxycycline, enrofloxacin, oxytetracycline, and tylosin (all <1 microg/ml) were lower than those of chloramphenicol (32 micro/ml) and erythromycin (64 microg/ml). The profile was identical to that of Mycoplasma alligatoris, previously isolated from American alligators (Alligator mississippiensis). M. iguanae strain 2327T was subcultured without antibiotics to assess mycoplasmacidal activity. Clindamycin, doxycycline, oxytetracycline, and tylosin were bacteriostatic from 0.1 to 0.5 microg/ml, whereas enrofloxacin was bactericidal at 20 ng/ml. An enrofloxacin dosage of 5-10 mg/kg achieves peak plasma concentrations >1 microg/ml, with an elimination half-life of 6-20 hr, in alligators. Although concentrations achieved in the vertebrae by i.m. or i.v. injection are probably lower than those in plasma, these data suggest that enrofloxacin may be useful to treat M. iguanae mycoplasmosis in iguanas.
Measurement of viscosity of gaseous mixtures at atmospheric pressure
NASA Technical Reports Server (NTRS)
Singh, J. J.; Mall, G. H.; Chegini, H.
1986-01-01
Coefficients of viscosity of various types of gas mixtures, including simulated natural-gas samples, have been measured at atmospheric pressure and room temperature using a modified capillary tube method. Pressure drops across the straight capillary tube section of a thermal mass flowmeter were measured for small, well-defined, volume flow rates for the test gases and for standard air. In this configuration, the flowmeter provides the volumetric flow rates as well as a well-characterized capillary section for differential pressure measurements across it. The coefficients of viscosity of the test gases were calculated using the reported value of 185.6 micro P for the viscosity of air. The coefficients of viscosity for the test mixtures were also calculated using Wilke's approximation of the Chapman-Enskog (C-E) theory. The experimental and calculated values for binary mixtures are in agreement within the reported accuracy of Wilke's approximation of the C-E theory. However, the agreement for multicomponent mixtures is less satisfactory, possible because of the limitations of Wilkes's approximation of the classical dilute-gas state model.
Bridging meso- and microscopic anisotropic unilateral damage formulations for microcracked solids
NASA Astrophysics Data System (ADS)
Zhu, Qi-Zhi; Yuan, Shuang-Shuang; Shao, Jian-fu
2017-04-01
A mathematically consistent and unified description of induced anisotropy and unilateral effects constitutes one of the central tasks in the continuum damage theories developed so far. This paper aims at bridging constitutive damage formulations on meso- and micro-scales with an emphasis on a complete mesoscopic determination of material effective properties for microcracked solids. The key is to introduce a new set of invariants in terms of strain tensor and fabric tensor by making use of the Walpole's tensorial base. This invariant set proves to be equivalent to the classical one, while the new one provides great conveniences to high-order orientation-dependent tensor manipulations. When limited to the case of parallel microcracks, potential relations between ten combination coefficients are established by applying continuity conditions. It is found that the dilute approximation with penny-shaped microcracks is a particular case of the present one. By originally introducing effective strain effect, interactions between microcracks are taken into account with comparison to the Mori-Tanaka method as well as the Ponte-Castaneda and Willis scheme. For completeness, discussions are also addressed on macroscopic formulations with high-order damage variables.
Agyare, Christian; Koffuor, George Asumeng; Boamah, Vivian Etsiapa; Adu, Francis; Mensah, Kwesi Boadu; Adu-Amoah, Louis
2012-01-01
Pterygota macrocarpa and Cola gigantea are African medicinal plants used in traditional medicine for the treatment of sores, skin infections, and other inflammatory conditions including pains. This study therefore aims at investigating the antimicrobial properties of ethanol leaf and stem bark extracts of P. macrocarpa and C. gigantea using the agar diffusion and the micro-dilution techniques and also determining the anti-inflammatory properties of the extracts of these plants in carrageenan-induced foot edema in seven-day old chicks. The minimum inhibitory concentration of both ethanol leaf and bark extracts of P. macrocarpa against the test organisms was from 0.125 to 2.55 mg/mL and that of C. gigantea extracts was 0.125 to 2.75 mg/mL. Extracts with concentration of 50 mg/mL were most active against the test organisms according to the agar diffusion method. All the extracts of P. macrocarpa and C. gigantea at 30, 100, and 300 mg/kg body weight except ethanol leaf extract of C. gigantea exhibited significant anti-inflammatory effects (P ≤ 0.001). PMID:22690251
Quantitation of immunoadsorbed flavoprotein oxidases by luminol-mediated chemiluminescence.
Hinkkanen, A; Maly, F E; Decker, K
1983-04-01
The detection of the flavoenzymes 6-hydroxy-L-nicotine oxidase and 6-hydroxy-D-nicotine oxidase at the sub-femtomol level was achieved by coupling the reaction of the immunoadsorbed proteins to the peroxidase-catalysed oxidation of luminol. The H2O2-producing oxidases retained their full activity when bound to the respective immobilized antibodies. This fact allowed the concentration of the enzymes from very dilute solutions and the quantitative assay of their activities in the microU range. Due to strict stereoselectivity and the absence of immunological cross-reactivity, the two flavoproteins could be determined in the same solution. This method was used to measure the 6-hydroxy-D-nicotine oxidase and 6-hydroxy-L-nicotine oxidase activities in Escherichia coli RR1 and different Arthrobacter strains cultured under non-inducing conditions. The same activity ratio of 6-hydroxy-L-nicotine oxidase/6-hydroxy-D-nicotine oxidase as in D L-nicotine-induced cells of A. oxidans was observed in non-induced wild type and in riboflavin-requiring (rf-) mutant cells of this aerob.
Roosta, Mostafa; Ghaedi, Mehrorang; Daneshfar, Ali
2014-10-15
A novel approach, ultrasound-assisted reverse micelles dispersive liquid-liquid microextraction (USA-RM-DLLME) followed by high performance liquid chromatography (HPLC) was developed for selective determination of acetoin in butter. The melted butter sample was diluted and homogenised by n-hexane and Triton X-100, respectively. Subsequently, 400μL of distilled water was added and the microextraction was accelerated by 4min sonication. After 8.5min of centrifugation, sedimented phase (surfactant-rich phase) was withdrawn by microsyringe and injected into the HPLC system for analysis. The influence of effective variables was optimised using Box-Behnken design (BBD) combined with desirability function (DF). Under optimised experimental conditions, the calibration graph was linear over the range of 0.6-200mgL(-1). The detection limit of method was 0.2mgL(-1) and coefficient of determination was 0.9992. The relative standard deviations (RSDs) were less than 5% (n=5) while the recoveries were in the range of 93.9-107.8%. Copyright © 2014. Published by Elsevier Ltd.
Button, Mark; Weber, Kela; Nivala, Jaime; Aubron, Thomas; Müller, Roland Arno
2016-03-01
Community-level physiological profiling (CLPP) using BIOLOG® EcoPlates™ has become a popular method for characterizing and comparing the functional diversity, functional potential, and metabolic activity of heterotrophic microbial communities. The method was originally developed for profiling soil communities; however, its usage has expanded into the fields of ecotoxicology, agronomy, and the monitoring and profiling of microbial communities in various wastewater treatment systems, including constructed wetlands for water pollution control. When performing CLPP on aqueous samples from constructed wetlands, a wide variety of sample characteristics can be encountered and challenges may arise due to excessive solids, color, or turbidity. The aim of this study was to investigate the impacts of different sample preparation methods on CLPP performed on a variety of aqueous samples covering a broad range of physical and chemical characteristics. The results show that using filter paper, centrifugation, or settling helped clarify samples for subsequent CLPP analysis, however did not do so as effectively as dilution for the darkest samples. Dilution was able to provide suitable clarity for the darkest samples; however, 100-fold dilution significantly affected the carbon source utilization patterns (CSUPs), particularly with samples that were already partially or fully clear. Ten-fold dilution also had some effect on the CSUPs of samples which were originally clear; however, the effect was minimal. Based on these findings, for this specific set of samples, a 10-fold dilution provided a good balance between ease of use, sufficient clarity (for dark samples), and limited effect on CSUPs. The process and findings outlined here can hopefully serve future studies looking to utilize CLPP for functional analysis of microbial communities and also assist in comparing data from studies where different sample preparation methods were utilized.
Peng, Wei; Lan, Wei; Zhong, Jiancheng; Wang, Jianxin; Pan, Yi
2017-07-15
MicroRNAs have been reported to have close relationship with diseases due to their deregulation of the expression of target mRNAs. Detecting disease-related microRNAs is helpful for disease therapies. With the development of high throughput experimental techniques, a large number of microRNAs have been sequenced. However, it is still a big challenge to identify which microRNAs are related to diseases. Recently, researchers are interesting in combining multiple-biological information to identify the associations between microRNAs and diseases. In this work, we have proposed a novel method to predict the microRNA-disease associations based on four biological properties. They are microRNA, disease, gene and environment factor. Compared with previous methods, our method makes predictions not only by using the prior knowledge of associations among microRNAs, disease, environment factors and genes, but also by using the internal relationship among these biological properties. We constructed four biological networks based on the similarity of microRNAs, diseases, environment factors and genes, respectively. Then random walking was implemented on the four networks unequally. In the walking course, the associations can be inferred from the neighbors in the same networks. Meanwhile the association information can be transferred from one network to another. The results of experiment showed that our method achieved better prediction performance than other existing state-of-the-art methods. Copyright © 2017 Elsevier Inc. All rights reserved.
An Isotopic Dilution Experiment Using Liquid Scintillation: A Simple Two-System, Two-Phase Analysis.
ERIC Educational Resources Information Center
Moehs, Peter J.; Levine, Samuel
1982-01-01
A simple isotonic, dilution analysis whose principles apply to methods of more complex radioanalyses is described. Suitable for clinical and instrumental analysis chemistry students, experimental manipulations are kept to a minimum involving only aqueous extraction before counting. Background information, procedures, and results are discussed.…
Method and apparatus for actively controlling a micro-scale flexural plate wave device
Dohner, Jeffrey L.
2001-01-01
An actively controlled flexural plate wave device provides a micro-scale pump. A method of actively controlling a flexural plate wave device produces traveling waves in the device by coordinating the interaction of a magnetic field with actively controlled currents. An actively-controlled flexural plate wave device can be placed in a fluid channel and adapted for use as a micro-scale fluid pump to cool or drive micro-scale systems, for example, micro-chips, micro-electrical-mechanical devices, micro-fluid circuits, or micro-scale chemical analysis devices.
Unusual Carrier Thermalization in a Dilute GaAs1-xNx Alloy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tan, P. H.; Xu, Z. Y.; Luo, X. D.
2007-01-01
Photoluminescence (PL) properties of the E{sub 0}, E{sub 0} + {Delta}{sub 0}, and E{sub +} bands in an x=0.62% GaAs{sub 1-x}N{sub x} alloy were investigated in detail, including their peak position, linewidth, and line shape dependences on the excitation energy, excitation power, and temperature, using micro-PL. The hot electrons within the E{sub +} band are found to exhibit highly unusual thermalization, which results in a large blueshift in its PL peak energy by >2k{sub B}T, suggesting peculiar density of states and carrier dynamics of the E{sub +} band.
Micro Machining of Injection Mold Inserts for Fluidic Channel of Polymeric Biochips
Jung, Woo-Chul; Heo, Young-Moo; Yoon, Gil-Sang; Shin, Kwang-Ho; Chang, Sung-Ho; Kim, Gun-Hee; Cho, Myeong-Woo
2007-01-01
Recently, the polymeric micro-fluidic biochip, often called LOC (lab-on-a-chip), has been focused as a cheap, rapid and simplified method to replace the existing biochemical laboratory works. It becomes possible to form miniaturized lab functionalities on a chip with the development of MEMS technologies. The micro-fluidic chips contain many micro-channels for the flow of sample and reagents, mixing, and detection tasks. Typical substrate materials for the chip are glass and polymers. Typical techniques for microfluidic chip fabrication are utilizing various micro pattern forming methods, such as wet-etching, micro-contact printing, and hot-embossing, micro injection molding, LIGA, and micro powder blasting processes, etc. In this study, to establish the basis of the micro pattern fabrication and mass production of polymeric micro-fluidic chips using injection molding process, micro machining method was applied to form micro-channels on the LOC molds. In the research, a series of machining experiments using micro end-mills were performed to determine optimum machining conditions to improve surface roughness and shape accuracy of designed simplified micro-channels. Obtained conditions were used to machine required mold inserts for micro-channels using micro end-mills. Test injection processes using machined molds and COC polymer were performed, and then the results were investigated.
Butterworth, Alice S; Robertson, Alan J; Ho, Mei-Fong; Gatton, Michelle L; McCarthy, James S; Trenholme, Katharine R
2011-04-18
Obtaining single parasite clones is required for many techniques in malaria research. Cloning by limiting dilution using microscopy-based assessment for parasite growth is an arduous and labor-intensive process. An alternative method for the detection of parasite growth in limiting dilution assays is using a commercial ELISA histidine-rich protein II (HRP2) detection kit. Detection of parasite growth was undertaken using HRP2 ELISA and compared to thick film microscopy. An HRP2 protein standard was used to determine the detection threshold of the HRP2 ELISA assay, and a HRP2 release model was used to extrapolate the amount of parasite growth required for a positive result. The HRP2 ELISA was more sensitive than microscopy for detecting parasite growth. The minimum level of HRP2 protein detection of the ELISA was 0.11 ng/ml. Modeling of HRP2 release determined that 2,116 parasites are required to complete a full erythrocytic cycle to produce sufficient HRP2 to be detected by the ELISA. Under standard culture conditions this number of parasites is likely to be reached between 8 to 14 days of culture. This method provides an accurate and simple way for the detection of parasite growth in limiting dilution assays, reducing time and resources required in traditional methods. Furthermore the method uses spent culture media instead of the parasite-infected red blood cells, enabling culture to continue. © 2011 Butterworth et al; licensee BioMed Central Ltd.
Methods of preventing vinorelbine-induced phlebitis: an experimental study in rabbits
Kohno, Emiko; Murase, Saori; Nishikata, Mayumi; Okamura, Noboru; Matzno, Sumio; Kuwahara, Takashi; Matsuyama, Kenji
2008-01-01
Purpose: In order to identify methods for preventing phlebitis caused by intravenous administration of vinorelbine (VNR), we established a procedure for estimating the severity of phlebitis in an animal model. Methods: Four different factors (administration rate, dilution, flushing, and infusion of fat emulsion) were evaluated for alleviation of phlebitis caused by VNR infusion. VNR was diluted with normal saline to prepare test solutions with concentrations of 0.6 mg/mL or 0.3 mg/mL for infusion into the auricular veins of rabbits. Two days after VNR infusion, the veins were subjected to histopathological examination. Results: VNR did not cause obvious loss of venous endothelial cells, the most sensitive and common feature of phlebitis, but VNR infusion led to inflammatory cell infiltration, edema, and epidermal degeneration. Tissue damage was significantly decreased by shortening the administration time and by diluting the VNR solution for infusion from 0.6 mg/mL to 0.3 mg/mL. However, there was no effect of flushing with normal saline after VNR infusion, while treatment with fat emulsion before and after VNR infusion only had a minimal effect. Conclusion: Rapid infusion and dilution are effective methods of reducing phlebitis caused by the infusion of VNR, but the efficacy of flushing with normal saline or infusion of fat emulsion was not confirmed. PMID:18695742
Methods and Devices for Micro-Isolation, Extraction, and/or Analysis of Microscale Components
NASA Technical Reports Server (NTRS)
Wade, Lawrence A. (Inventor); Kartalov, Emil P. (Inventor); Taylor, Clive (Inventor); Shibata, Darryl (Inventor)
2014-01-01
Provided herein are devices and methods for the micro-isolation of biological cellular material. A micro-isolation apparatus described can comprise a photomask that protects regions of interest against DNA-destroying illumination. The micro-isolation apparatus can further comprise photosensitive material defining access wells following illumination and subsequent developing of the photosensitive material. The micro-isolation apparatus can further comprise a chambered microfluidic device comprising channels providing access to wells defined in photosensitive material. The micro-isolation apparatus can comprise a chambered microfluidic device without access wells defined in photosensitive material where valves control the flow of gases or liquids through the channels of the microfluidic device. Also included are methods for selectively isolating cellular material using the apparatuses described herein, as are methods for biochemical analysis of individual regions of interest of cellular material using the devices described herein. Further included are methods of making masking arrays useful for the methods described herein.
Alevizos, Ilias; Alexander, Stefanie; Turner, R. James; Illei, Gabor G.
2013-01-01
Objective MicroRNA reflect physiologic and pathologic processes and may be used as biomarkers of concurrent pathophysiologic events in complex settings such as autoimmune diseases. We generated microRNA microarray profiles from the minor salivary glands of control subjects without Sjögren's syndrome (SS) and patients with SS who had low-grade or high-grade inflammation and impaired or normal saliva production, to identify microRNA patterns specific to salivary gland inflammation or dysfunction. Methods MicroRNA expression profiles were generated by Agilent microRNA arrays. We developed a novel method for data normalization by identifying housekeeping microRNA. MicroRNA profiles were compared by unsupervised mathematical methods to test how well they distinguish between control subjects and various subsets of patients with SS. Several bioinformatics methods were used to predict the messenger RNA targets of the differentially expressed microRNA. Results MicroRNA expression patterns accurately distinguished salivary glands from control subjects and patients with SS who had low-degree or high-degree inflammation. Using real-time quantitative polymerase chain reaction, we validated 2 microRNA as markers of inflammation in an independent cohort. Comparing microRNA from patients with preserved or low salivary flow identified a set of differentially expressed microRNA, most of which were up-regulated in the group with decreased salivary gland function, suggesting that the targets of microRNA may have a protective effect on epithelial cells. The predicted biologic targets of microRNA associated with inflammation or salivary gland dysfunction identified both overlapping and distinct biologic pathways and processes. Conclusion Distinct microRNA expression patterns are associated with salivary gland inflammation and dysfunction in patients with SS, and microRNA represent a novel group of potential biomarkers. PMID:21280008
Optimization of miRNA-seq data preprocessing.
Tam, Shirley; Tsao, Ming-Sound; McPherson, John D
2015-11-01
The past two decades of microRNA (miRNA) research has solidified the role of these small non-coding RNAs as key regulators of many biological processes and promising biomarkers for disease. The concurrent development in high-throughput profiling technology has further advanced our understanding of the impact of their dysregulation on a global scale. Currently, next-generation sequencing is the platform of choice for the discovery and quantification of miRNAs. Despite this, there is no clear consensus on how the data should be preprocessed before conducting downstream analyses. Often overlooked, data preprocessing is an essential step in data analysis: the presence of unreliable features and noise can affect the conclusions drawn from downstream analyses. Using a spike-in dilution study, we evaluated the effects of several general-purpose aligners (BWA, Bowtie, Bowtie 2 and Novoalign), and normalization methods (counts-per-million, total count scaling, upper quartile scaling, Trimmed Mean of M, DESeq, linear regression, cyclic loess and quantile) with respect to the final miRNA count data distribution, variance, bias and accuracy of differential expression analysis. We make practical recommendations on the optimal preprocessing methods for the extraction and interpretation of miRNA count data from small RNA-sequencing experiments. © The Author 2015. Published by Oxford University Press.
Intraperitoneal AAV9-shRNA inhibits target expression in neonatal skeletal and cardiac muscles.
Mayra, Azat; Tomimitsu, Hiroyuki; Kubodera, Takayuki; Kobayashi, Masaki; Piao, Wenying; Sunaga, Fumiko; Hirai, Yukihiko; Shimada, Takashi; Mizusawa, Hidehiro; Yokota, Takanori
2011-02-11
Systemic injections of AAV vectors generally transduce to the liver more effectively than to cardiac and skeletal muscles. The short hairpin RNA (shRNA)-expressing AAV9 (shRNA-AAV9) can also reduce target gene expression in the liver, but not enough in cardiac or skeletal muscles. Higher doses of shRNA-AAV9 required for inhibiting target genes in cardiac and skeletal muscles often results in shRNA-related toxicity including microRNA oversaturation that can induce fetal liver failure. In this study, we injected high-dose shRNA-AAV9 to neonates and efficiently silenced genes in cardiac and skeletal muscles without inducing liver toxicity. This is because AAV is most likely diluted or degraded in the liver than in cardiac or skeletal muscle during cell division after birth. We report that this systemically injected shRNA-AAV method does not induce any major side effects, such as liver dysfunction, and the dose of shRNA-AAV is sufficient for gene silencing in skeletal and cardiac muscle tissues. This novel method may be useful for generating gene knockdown in skeletal and cardiac mouse tissues, thus providing mouse models useful for analyzing diseases caused by loss-of-function of target genes. Copyright © 2011 Elsevier Inc. All rights reserved.
Making the invisible visible: a microfluidic chip using a low refractive index polymer.
Hanada, Yasutaka; Ogawa, Tatsuya; Koike, Kazuhiko; Sugioka, Koji
2016-07-07
Microfluidic frameworks known as micro-total-analysis-systems or lab-on-a-chip have become versatile tools in cell biology research, since functional biochips are able to streamline dynamic observations of various cells. Glass or polymers are generally used as the substrate due to their high transparency, chemical stability and cost-effectiveness. However, these materials are not well suited for the microscopic observation of cell migration at the fluid boundary due to the refractive index mismatch between the medium and the biochip material. For this reason, we have developed a new method of fabricating three-dimensional (3D) microfluidic chips made of the low refractive index fluoric polymer CYTOP. This novel fabrication procedure involves the use of a femtosecond laser for direct writing, followed by wet etching with a dilute fluorinated solvent and annealing, to create high-quality 3D microfluidic chips inside a polymer substrate. A microfluidic chip made in this manner enabled us to more clearly observe the flagellum motion of a Dinoflagellate moving in circles near the fluid surface compared to the observations possible using conventional microfluidic chips. We believe that CYTOP microfluidic chips made using this new method may allow more detailed analysis of various cell migrations near solid boundaries.
Maesaki, Shigefumi; Yamaguchi, Toshiyuki; Sasaki, Kazumasa; Hashikita, Giichi; Shibuya, Shunsuke; Watanabe, Masaharu; Takayama, Sadao; Kawakami, Sayoko; Nagasawa, Mitsuaki; Suzuki, Noriyasu; Uchida, Takashi; Okabe, Tadashi; Kobayashi, Sugako
2006-02-01
The effectiveness of antibacterial agents against 70 strains of clinically isolated multiple-drug resistant Pseudomonas aeruginosa (MDRP) was measured by the micro dilution method. Fifty of all strains (71%) produced metallo-beta-lactamase and the IMP-1 gene was detected by polymerase chain reaction (PCR). The MIC90 (the minimum inhibitory concentration of an antibiotic necessary to inhibit the growth of 90% of bacterial strains) values of biapenem (BIPM), meropenem (MEPM), tazobactam/piperacillin (TAZ/PIPC), sulbactam/ cefoperazone (SBT/CPZ), cefepime (CFPM), ciprofloxacin (CPFX), pazufloxacin (PZFX), amikacin (AMK) and aztreonam (AZT) were found to be 265, 512, 256, 512, 512, 64, 128, 128 and 128 microg/mL, respectively. The in vitro combination effects of antibacterial agents were examined against 62 strains of MDRP and the synergy or additive effects were evaluated by fractional inhibitory concentration (FIC) index calculated by the checkerboard method. The combination of AMK and AZT showed synergy effects on 15/59 (25.4%) strains of MDRP. The synergy and additive effects on the MDRP strains were also found by the other antibacterial agents combination such as TAZ/PIPC and AMK, CFPM and AMK, and SBT/CPZ and AZT. These results suggested the necessity of further investigation of clinical usefulness.
Optoacoustic detection of viral antigens using targeted gold nanorods
NASA Astrophysics Data System (ADS)
Maswadi, Saher; Woodward, Lee; Glickman, Randolph D.; Barsalou, Norman
2009-02-01
We are detecting antigens (Ag), isolated from infectious organisms, utilizing laser optoacoustic spectroscopy and antibody-coupled gold nanorod (NR) contrast agents specifically targeted to the antigen of interest. We have detected, in clinical ocular samples, both Herpes Simplex Virus Type 1 and 2 (HSV-1 and HSV-2) . A monoclonal antibody (Ab) specific to both HSV-1 and HSV-2 was conjugated to gold nanorods to produce a targeted contrast agent with a strong optoacoustic signal. Elutions obtained from patient corneal swabs were adsorbed in standard plastic micro-wells. An immunoaffinity reaction was then performed with the functionalized gold nanorods, and the results were probed with an OPO laser, emitting wavelengths at the peak absorptions of the nanorods. Positive optoacoustic responses were obtained from samples containing authentic (microbiologically confirmed) HSV-1 and HSV-2. To obtain an estimate of the sensitivity of the technique, serial dilutions from 1 mg/ml to 1 pg/ml of a C. trachomatis surface Ag were prepared, and were probed with a monoclonal Ab, specific to the C. trachomatis surface Ag, conjugated to gold nanorods. An optoacoustic response was obtained, proportional to the concentration of antigen, and with a limit of detection of about 5 pg/ml. The optoacoustic signals generated from micro-wells containing albumin or saline were similar to those from blank wells. The potential benefit of this method is identify viral agents more rapidly than with existing techniques. In addition, the sensitivity of the assay is comparable or superior to existing colorimetric- or fluorometric-linked immunoaffinity assays.
Alternative Fuels Research Laboratory
NASA Technical Reports Server (NTRS)
Surgenor, Angela D.; Klettlinger, Jennifer L.; Nakley, Leah M.; Yen, Chia H.
2012-01-01
NASA Glenn has invested over $1.5 million in engineering, and infrastructure upgrades to renovate an existing test facility at the NASA Glenn Research Center (GRC), which is now being used as an Alternative Fuels Laboratory. Facility systems have demonstrated reliability and consistency for continuous and safe operations in Fischer-Tropsch (F-T) synthesis and thermal stability testing. This effort is supported by the NASA Fundamental Aeronautics Subsonic Fixed Wing project. The purpose of this test facility is to conduct bench scale F-T catalyst screening experiments. These experiments require the use of a synthesis gas feedstock, which will enable the investigation of F-T reaction kinetics, product yields and hydrocarbon distributions. Currently the facility has the capability of performing three simultaneous reactor screening tests, along with a fourth fixed-bed reactor for catalyst activation studies. Product gas composition and performance data can be continuously obtained with an automated gas sampling system, which directly connects the reactors to a micro-gas chromatograph (micro GC). Liquid and molten product samples are collected intermittently and are analyzed by injecting as a diluted sample into designated gas chromatograph units. The test facility also has the capability of performing thermal stability experiments of alternative aviation fuels with the use of a Hot Liquid Process Simulator (HLPS) (Ref. 1) in accordance to ASTM D 3241 "Thermal Oxidation Stability of Aviation Fuels" (JFTOT method) (Ref. 2). An Ellipsometer will be used to study fuel fouling thicknesses on heated tubes from the HLPS experiments. A detailed overview of the test facility systems and capabilities are described in this paper.
Improvement of pre-treatment method for 36Cl/Cl measurement of Cl in natural groundwater by AMS
NASA Astrophysics Data System (ADS)
Nakata, Kotaro; Hasegawa, Takuma
2011-02-01
Estimation of 36Cl/Cl by accelerator mass spectrometry (AMS) is a useful method to trace hydrological processes in groundwater. For accurate estimation, separation of SO42- from Cl - in groundwater is required because 36S affects AMS measurement of 36Cl. Previous studies utilized the difference in solubility between BaSO 4 and BaCl 2 (BaSO 4 method) to chemically separate SO42- from Cl -. However, the accuracy of the BaSO 4 method largely depends on operator skill, and consequently Cl - recovery is typically incomplete (70-80%). In addition, the method is time consuming (>1 week), and cannot be applied directly to dilute solutions. In this study, a method based on ion-exchange column chromatography (column method) was developed for separation of Cl - and SO42-. Optimum conditions were determined for the diameter and height of column, type and amount of resin, type and concentration of eluent, and flow rate. The recovery of Cl - was almost 100%, which allowed complete separation from SO42-. The separation procedure was short (<6 h), and was successfully applied to dilute (1 mg/L Cl) solution. Extracted pore water and diluted seawater samples were processed by the column and BaSO 4 methods, and then analyzed by AMS to estimate 36S counts and 36Cl/Cl values. 36S counts in samples processed by the column method were stable and lower than those from the BaSO 4 method. The column method has the following advantages over the BaSO 4 method: (1) complete and stable separation of Cl - and SO42-, (2) less operator influence on results, (3) short processing time (<6 h), (4) high (almost 100%) recovery of Cl -, and (5) concentration of Cl - and separation from SO42- in the one system for dilute solutions.
Liu, Chung-Ming; Chen, Jui-Wen; Tsai, Jen-Hui; Lin, Wei-Shian; Yen, M-T; Chen, Ting-Hao
2012-01-01
This study determines whether environment-protecting pervious pavement can dilute pollutants immediately after emissions from vehicle. The turbulence-driven dry-deposition process is too slow to be considered in this aspect. The pavement used is the JW pavement (according to its inventors name), a high-load-bearing water-permeable pavement with patents in over 100 countries, which has already been used for more than 8 years in Taiwan and is well suited to replacing conventional road pavement, making the potential implementation of the study results feasible. The design of this study included two sets of experiments. Variation of the air pollutant concentrations within a fenced area over the JW pavement with one vehicle discharging emissions into was monitored and compared with results over a non-JW pavement. The ambient wind speed was low during the first experiment, and the results obtained were highly credible. It was found that the JW pavement diluted vehicle pollutant emissions near the ground surface by 40%-87% within 5 min of emission; whereas the data at 2 m height suggested that about 58%-97% of pollutants were trapped underneath the pavement 20 min after emission. Those quantitative estimations may be off by +/- 10%, if errors in emissions and measurements were considered. SO2 and CO2 underwent the most significant reduction. Very likely, pollutants were forced to move underneath due to the special design of the pavement. During the second experiment, ambient wind speeds were high and the results obtained had less credibility, but they did not disprove the pollutant dilution capacity of the JW pavement. In order to track the fate of pollutants, parts of the pavement were removed to reveal a micro version of wetland underneath, which could possibly hold the responsibility of absorbing and decomposing pollutants to forms harmless to the environment and human health.
Analysis of Membrane Lipids of Airborne Micro-Organisms
NASA Technical Reports Server (NTRS)
MacNaughton, Sarah
2006-01-01
A method of characterization of airborne micro-organisms in a given location involves (1) large-volume filtration of air onto glass-fiber filters; (2) accelerated extraction of membrane lipids of the collected micro-organisms by use of pressurized hot liquid; and (3) identification and quantitation of the lipids by use of gas chromatography and mass spectrometry. This method is suitable for use in both outdoor and indoor environments; for example, it can be used to measure airborne microbial contamination in buildings ("sick-building syndrome"). The classical approach to analysis of airborne micro-organisms is based on the growth of cultureable micro-organisms and does not provide an account of viable but noncultureable micro-organisms, which typically amount to more than 90 percent of the micro-organisms present. In contrast, the present method provides an account of all micro-organisms, including cultureable, noncultureable, aerobic, and anaerobic ones. The analysis of lipids according to this method makes it possible to estimate the number of viable airborne micro-organisms present in the sampled air and to obtain a quantitative profile of the general types of micro-organisms present along with some information about their physiological statuses.
Dual-energy micro-CT imaging of pulmonary airway obstruction: correlation with micro-SPECT
NASA Astrophysics Data System (ADS)
Badea, C. T.; Befera, N.; Clark, D.; Qi, Y.; Johnson, G. A.
2014-03-01
To match recent clinical dual energy (DE) CT studies focusing on the lung, similar developments for DE micro-CT of the rodent lung are required. Our group has been actively engaged in designing pulmonary gating techniques for micro- CT, and has also introduced the first DE micro-CT imaging method of the rodent lung. The aim of this study was to assess the feasibility of DE micro-CT imaging for the evaluation of airway obstruction in mice, and to compare the method with micro single photon emission computed tomography (micro-SPECT) using technetium-99m labeled macroaggregated albumin (99mTc-MAA). The results suggest that the induced pulmonary airway obstruction causes either atelectasis, or air-trapping similar to asthma or chronic bronchitis. Atelectasis could only be detected at early time points in DE micro-CT images, and is associated with a large increase in blood fraction and decrease in air fraction. Air trapping had an opposite effect with larger air fraction and decreased blood fraction shown by DE micro-CT. The decrease in perfusion to the hypoventilated lung (hypoxic vasoconstriction) is also seen in micro-SPECT. The proposed DE micro-CT technique for imaging localized airway obstruction performed well in our evaluation, and provides a higher resolution compared to micro-SPECT. Both DE micro-CT and micro-SPECT provide critical, quantitative lung biomarkers for image-based anatomical and functional information in the small animal. The methods are readily linked to clinical methods allowing direct comparison of preclinical and clinical results.
It has been fifty years since Kirkham and Bartholmew (1954) presented the conceptual framework and derived the mathematical equations that formed the basis of the now commonly employed method of 15N isotope dilution. Although many advances in methodology and analysis have been ma...
Methods of preventing vinorelbine-induced phlebitis: an experimental study in rabbits.
Kohno, Emiko; Murase, Saori; Nishikata, Mayumi; Okamura, Noboru; Matzno, Sumio; Kuwahara, Takashi; Matsuyama, Kenji
2008-07-22
In order to identify methods for preventing phlebitis caused by intravenous administration of vinorelbine (VNR), we established a procedure for estimating the severity of phlebitis in an animal model. Four different factors (administration rate, dilution, flushing, and infusion of fat emulsion) were evaluated for alleviation of phlebitis caused by VNR infusion. VNR was diluted with normal saline to prepare test solutions with concentrations of 0.6 mg/mL or 0.3 mg/mL for infusion into the auricular veins of rabbits. Two days after VNR infusion, the veins were subjected to histopathological examination. VNR did not cause obvious loss of venous endothelial cells, the most sensitive and common feature of phlebitis, but VNR infusion led to inflammatory cell infiltration, edema, and epidermal degeneration. Tissue damage was significantly decreased by shortening the administration time and by diluting the VNR solution for infusion from 0.6 mg/mL to 0.3 mg/mL. However, there was no effect of flushing with normal saline after VNR infusion, while treatment with fat emulsion before and after VNR infusion only had a minimal effect. Rapid infusion and dilution are effective methods of reducing phlebitis caused by the infusion of VNR, but the efficacy of flushing with normal saline or infusion of fat emulsion was not confirmed.
Palenzuela, D O; Benítez, J; Rivero, J; Serrano, R; Ganzó, O
1997-10-13
In the present work a concept proposed in 1992 by Dopotka and Giesendorf was applied to the quantitative analysis of antibodies to the p24 protein of HIV-1 in infected asymptomatic individuals and AIDS patients. Two approaches were analyzed, a linear model OD = b0 + b1.log(titer) and a nonlinear log(titer) = alpha.OD beta, similar to the Dopotka-Giesendorf's model. The above two proposed models adequately fit the dependence of the optical density values at a single point dilution, and titers achieved by the end point dilution method (EPDM). Nevertheless, the nonlinear model better fits the experimental data, according to residuals analysis. Classical EPDM was compared with the new single point dilution method (SPDM) using both models. The best correlation between titers calculated using both models and titers achieved by EPDM was obtained with the nonlinear model. The correlation coefficients for the nonlinear and linear models were r = 0.85 and r = 0.77, respectively. A new correction factor was introduced into the nonlinear model and this reduced the day-to-day variation of titer values. In general, SPDM saves time, reagents and is more precise and sensitive to changes in antibody levels, and therefore has a higher resolution than EPDM.
Microfabricated instruments and methods to treat recurrent corneal erosions
Britton, Jr., Charles L.; D'urso, Brian R.; Chaum, Edward; Simpson, John T.; Baba, Justin S.; Ericson, M. Nance; Warmack, Robert J.
2015-06-02
In one embodiment, the present invention provides a device and method for treating recurrent corneal erosion. In one embodiment, the method includes the steps of contacting an epithelium layer of a cornea with an array of glass micro-rods including a plurality of sharp features having a length that penetrates a Bowman's layer of the eye, wherein the plurality of sharp features of the array of glass micro-rods produces a plurality of punctures in the Bowman's layer of the eye that are of micro-scale or less. In another embodiment, the present invention provides a method and device for drug delivery. In one embodiment, the device includes an array of glass micro-rods, wherein at least one glass micro-rod of the array of glass micro-rods includes a sharp feature opposite a base of the array of glass micro-rods, wherein the sharp feature includes a treated surface for delivering a chemical compound to the eye.
Microfabricated instruments and methods to treat recurrent corneal erosion
Britton, Charles L; D& #x27; Urso, Brian R; Chaum, Edward; Simpson, John T; Baba, Justin S; Ericson, M. Nance; Warmack, Robert J
2013-11-26
In one embodiment, the present invention provides a device and method for treating recurrent corneal erosion. In one embodiment, the method includes the steps of contacting an epithelium layer of a cornea with an array of glass micro-rods including a plurality of sharp features having a length that penetrates a Bowman's layer of the eye, wherein the plurality of sharp features of the array of glass micro-rods produces a plurality of punctures in the Bowman's layer of the eye that are of micro-scale or less. In another embodiment, the present invention provides a method and device for drug delivery. In one embodiment, the device includes an array of glass micro-rods, wherein at least one glass micro-rod of the array of glass micro-rods includes a sharp feature opposite a base of the array of glass micro-rods, wherein the sharp feature includes a treated surface for delivering a chemical compound to the eye.
NASA Astrophysics Data System (ADS)
Lazarenko, A. A.; Berezovskaya, T. N.; Denisov, D. V.; Sobolev, M. S.; Pirogov, E. V.; Nikitina, E. V.
2017-11-01
This article discusses the process of preparation of a silicon surface for subsequent growth of dilute nitride alloys by molecular-beam epitaxy. The method of preparation of Si (100) and Si (111) substrates was developed. This method provides reproducible high-quality silicon surface for molecular-beam epitaxy of Si-GaP heterostructures. As a result, it managed to reduce the eviction oxide temperature below 800 °C, which is an important parameter for the MBE technology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Malik, Afshan N., E-mail: afshan.malik@kcl.ac.uk; Shahni, Rojeen; Rodriguez-de-Ledesma, Ana
2011-08-19
Highlights: {yields} Mitochondrial dysfunction is central to many diseases of oxidative stress. {yields} 95% of the mitochondrial genome is duplicated in the nuclear genome. {yields} Dilution of untreated genomic DNA leads to dilution bias. {yields} Unique primers and template pretreatment are needed to accurately measure mitochondrial DNA content. -- Abstract: Circulating mitochondrial DNA (MtDNA) is a potential non-invasive biomarker of cellular mitochondrial dysfunction, the latter known to be central to a wide range of human diseases. Changes in MtDNA are usually determined by quantification of MtDNA relative to nuclear DNA (Mt/N) using real time quantitative PCR. We propose that themore » methodology for measuring Mt/N needs to be improved and we have identified that current methods have at least one of the following three problems: (1) As much of the mitochondrial genome is duplicated in the nuclear genome, many commonly used MtDNA primers co-amplify homologous pseudogenes found in the nuclear genome; (2) use of regions from genes such as {beta}-actin and 18S rRNA which are repetitive and/or highly variable for qPCR of the nuclear genome leads to errors; and (3) the size difference of mitochondrial and nuclear genomes cause a 'dilution bias' when template DNA is diluted. We describe a PCR-based method using unique regions in the human mitochondrial genome not duplicated in the nuclear genome; unique single copy region in the nuclear genome and template treatment to remove dilution bias, to accurately quantify MtDNA from human samples.« less
Sharma, Amit Kumar; Gangwar, Mayank; Kumar, Dharmendra; Nath, Gopal; Kumar Sinha, Akhoury Sudhir; Tripathi, Yamini Bhushan
2016-01-01
Objective: This study aims to evaluate the antimicrobial activity, phytochemical studies and thin layer chromatography analysis of machine oil, hexane extract of seed oil and methanol extract of presscake & latex of Jatropha curcas Linn (family Euphorbiaceae). Materials and Methods: J. curcas extracts were subjected to preliminary qualitative phytochemical screening to detect the major phytochemicals followed by its reducing power and content of phenol and flavonoids in different fractions. Thin layer chromatography was also performed using different solvent systems for the analysis of a number of constituents in the plant extracts. Antimicrobial activity was evaluated by the disc diffusion method, while the minimum inhibitory concentration, minimum bactericidal concentration and minimum fungicidal concentration were calculated by micro dilution method. Results: The methanolic fraction of latex and cake exhibited marked antifungal and antibacterial activities against Gram-positive and Gram-negative bacteria. Phytochemical analysis revealed the presence of alkaloids, saponins, tannins, terpenoids, steroids, glycosides, phenols and flavonoids. Reducing power showed dose dependent increase in concentration compared to standard Quercetin. Furthermore, this study recommended the isolation and separation of bioactive compounds responsible for the antibacterial activity which would be done by using different chromatographic methods such as high-performance liquid chromatography (HPLC), GC-MS etc. Conclusion: The results of the above study suggest that all parts of the plants possess potent antibacterial activity. Hence, it is important to isolate the active principles for further testing of antimicrobial and other biological efficacy. PMID:27516977
A Performance Improvement Method for Low-Cost Land Vehicle GPS/MEMS-INS Attitude Determination
Cong, Li; Li, Ercui; Qin, Honglei; Ling, Keck Voon; Xue, Rui
2015-01-01
Global positioning system (GPS) technology is well suited for attitude determination. However, in land vehicle application, low-cost single frequency GPS receivers which have low measurement quality are often used, and external factors such as multipath and low satellite visibility in the densely built-up urban environment further degrade the quality of the GPS measurements. Due to the low-quality receivers used and the challenging urban environment, the success rate of the single epoch ambiguity resolution for dynamic attitude determination is usually quite low. In this paper, a micro-electro-mechanical system (MEMS)—inertial navigation system (INS)-aided ambiguity resolution method is proposed to improve the GPS attitude determination performance, which is particularly suitable for land vehicle attitude determination. First, the INS calculated baseline vector is augmented with the GPS carrier phase and code measurements. This improves the ambiguity dilution of precision (ADOP), resulting in better quality of the unconstrained float solution. Second, the undesirable float solutions caused by large measurement errors are further filtered and replaced using the INS-aided ambiguity function method (AFM). The fixed solutions are then obtained by the constrained least squares ambiguity decorrelation (CLAMBDA) algorithm. Finally, the GPS/MEMS-INS integration is realized by the use of a Kalman filter. Theoretical analysis of the ADOP is given and experimental results demonstrate that our proposed method can significantly improve the quality of the float ambiguity solution, leading to high success rate and better accuracy of attitude determination. PMID:25760057
NASA Astrophysics Data System (ADS)
Nguyen, Minh-Hang; Nguyen, Hai-Binh; Nguyen, Tuan-Hung; Vu, Xuan-Manh; Lai, Jain-Ren; Tseng, Fan-Gang; Chen, Te-Chang; Lee, Ming-Chang
2016-05-01
This paper presents two facile methods to fabricate off-plane lenses made of SU-8, an epoxy-based negative photoresist from MicroChem, on glass for optical interconnection. The methods allow the fabrication of lenses with flexible spot size and focal length depending on SU-8 well size and SU-8 drop volume and viscosity. In the first method, SU-8 drops were applied directly into patterned SU-8 wells with Teflon-coated micropipettes, and were baked to become (a)-spherical lenses. The lens shape and size were mainly determined by SU-8 viscosity, ratio of drop volume to well volume, and baking temperature and time. In the second method, a glass substrate with SU-8 patterned wells was emerged in diluted SU-8, then drawn up and baked to form lenses. The lens shapes and sizes were mainly determined by SU-8 viscosity and well volume. By the two methods, SU-8 lenses were successfully fabricated with spot sizes varying in range from micrometers to hundred micrometers, and focal lengths varying in range of several millimeters, depending on the lens rim diameters and aspheric sag height. Besides, on-plane SU-8 lenses were fabricated by photolithography to work in conjunction with the off-plane SU-8 lenses. The cascaded lenses produced light spots reduced to several micrometers, and they can be applied as a coupler for light coupling from fiber/Light-emitting diode (LED) to microstructures and nanostructures. The results open up the path for fabricating novel optical microsystems for optical communication and optical sensing applications.
Micro rotary machine and methods for using same
Stalford, Harold L [Norman, OK
2012-04-17
A micro rotary machine may include a micro actuator and a micro shaft coupled to the micro actuator. The micro shaft comprises a horizontal shaft and is operable to be rotated by the micro actuator. A micro tool is coupled to the micro shaft and is operable to perform work in response to motion of the micro shaft.
Micro rotary machine and methods for using same
Stalford, Harold
2015-01-13
A micro rotary machine may include a micro actuator and a micro shaft coupled to the micro actuator. The micro shaft comprises a horizontal shaft and is operable to be rotated by the micro actuator. A micro tool is coupled to the micro shaft and is operable to perform work in response to motion of the micro shaft.
Damage to cochlear efferents following AF64A intoxication.
Smith, D W; Mount, R J
1993-07-01
Damage to cochlear efferents in chinchillas was assessed using transmission electron microscopy following unilateral treatment with the cholinotoxin ethylcholine mustard aziridinium ion (AF64A). AF64A was diluted in artificial perilymph to concentrations ranging from 0.5 to 100 microM. Survival times ranged from 1 to 12 weeks. At concentrations above 10 microM, widespread damage was noted to efferent fibers within the inner spiral bundle (ISB), tunnel spiral bundle (TSB), tunnel radial fibers (TRF) and efferent terminals at the base of OHCs. This damage included degeneration of fibers and terminals, delamination of mitochondria, vacuolization, and loss of cell membrane. However, at high concentrations, non-specific damage was also noted as thinnings or discontinuities of the membrane of OHCs and afferent fibers. At concentrations between 3 and 10 microM, selective damage was observed to efferent fibers within the ISB, TSB, TRF, and to terminals at the base of the OHCs, with all other structures appearing normal. At concentrations of 0.5 and 1 microM, damage was limited to efferent fibers within the TSB and ISB below the inner hair cells. In general, insult was greatest to middle- and basal-turn efferents, and longer survival times did not produce greater damage to, or loss of, efferents. These data suggest that at low concentrations, AF64A produces a partial yet selective degeneration of cochlear efferents within both the medial and lateral tracts, and that at the lowest concentrations used in these studies, AF64A produces a preferential insult on lateral olivocochlear efferents.
NASA Astrophysics Data System (ADS)
Peng, Cong; Fan, Yahong; Huang, Ziyuan; Han, Bangcheng; Fang, Jiancheng
2017-01-01
This paper presents a novel synchronous micro-vibration suppression method on the basis of the small gain theorem to reduce the frequency-varying synchronous micro-vibration forces for a magnetically suspended flywheel (MSFW). The proposed synchronous micro-vibration suppression method not only eliminates the synchronous current fluctuations to force the rotor spinning around the inertia axis, but also considers the compensation caused by the displacement stiffness in the permanent-magnet (PM)-biased magnetic bearings. Moreover, the stability of the proposed control system is exactly analyzed by using small gain theorem. The effectiveness of the proposed micro-vibration suppression method is demonstrated via the direct measurement of the disturbance forces for a MSFW. The main merit of the proposed method is that it provides a simple and practical method in suppressing the frequency varying micro-vibration forces and preserving the nominal performance of the baseline control system.
Methods and systems for micro bearings
Stalford, Harold L.
2012-10-09
A micro drive assembly may comprise a substrate, a micro shall oriented in-plane with the substrate and at least one micro bearing to support rotation of the micro shaft. The micro shaft and micro bearing may be in or less than the micrometer domain.
Ter Laak, E A; Pijpers, A; Noordergraaf, J H; Schoevers, E C; Verheijden, J H
1991-02-01
The MICs of 18 antimicrobial agents used against strains of three porcine Mycoplasma species were determined by a serial broth dilution method. Twenty field strains of M. hyorhinis, ten field strains of M. hyopneumoniae, six field strains of M. flocculare, and the type strains of these species were tested. Twelve field strains and the type strain of M. hyorhinis were also tested by an agar dilution method. Tests were read at various time points. When the broth dilution method was used, the final MIC had to be read 2 days after color changes had stopped. MICs of tetracycline, oxytetracycline, doxycycline, and minocycline were low for the three Mycoplasma species tested. MICs of chlortetracycline were 8 to 16 times higher than MICs of the other tetracyclines. Spiramycin, tylosin, kitasamycin, spectinomycin, tiamulin, lincomycin, and clindamycin were effective against all strains of M. hyorhinis and M. hyopneumoniae. The quinolones were highly effective against M. hyopneumoniae but less effective against M. hyorhinis. The susceptibility patterns for M. hyopneumoniae and M. flocculare were similar.
Ter Laak, E A; Pijpers, A; Noordergraaf, J H; Schoevers, E C; Verheijden, J H
1991-01-01
The MICs of 18 antimicrobial agents used against strains of three porcine Mycoplasma species were determined by a serial broth dilution method. Twenty field strains of M. hyorhinis, ten field strains of M. hyopneumoniae, six field strains of M. flocculare, and the type strains of these species were tested. Twelve field strains and the type strain of M. hyorhinis were also tested by an agar dilution method. Tests were read at various time points. When the broth dilution method was used, the final MIC had to be read 2 days after color changes had stopped. MICs of tetracycline, oxytetracycline, doxycycline, and minocycline were low for the three Mycoplasma species tested. MICs of chlortetracycline were 8 to 16 times higher than MICs of the other tetracyclines. Spiramycin, tylosin, kitasamycin, spectinomycin, tiamulin, lincomycin, and clindamycin were effective against all strains of M. hyorhinis and M. hyopneumoniae. The quinolones were highly effective against M. hyopneumoniae but less effective against M. hyorhinis. The susceptibility patterns for M. hyopneumoniae and M. flocculare were similar. PMID:2024954
Baral, Nawa Raj; Shah, Ajay
2017-05-01
Pretreatment is required to destroy recalcitrant structure of lignocelluloses and then transform into fermentable sugars. This study assessed techno-economics of steam explosion, dilute sulfuric acid, ammonia fiber explosion and biological pretreatments, and identified bottlenecks and operational targets for process improvement. Techno-economic models of these pretreatment processes for a cellulosic biorefinery of 113.5 million liters butanol per year excluding fermentation and wastewater treatment sections were developed using a modelling software-SuperPro Designer. Experimental data of the selected pretreatment processes based on corn stover were gathered from recent publications, and used for this analysis. Estimated sugar production costs ($/kg) via steam explosion, dilute sulfuric acid, ammonia fiber explosion and biological methods were 0.43, 0.42, 0.65 and 1.41, respectively. The results suggest steam explosion and sulfuric acid pretreatment methods might be good alternatives at present state of technology and other pretreatment methods require research and development efforts to be competitive with these pretreatment methods. Copyright © 2017 Elsevier Ltd. All rights reserved.
Meyer, Michael T.; Loftin, Keith A.; Lee, Edward A.; Hinshaw, Gary H.; Dietze, Julie E.; Scribner, Elisabeth A.
2009-01-01
The U.S. Geological Survey method (0-2141-09) presented is approved for the determination of glyphosate, its degradation product aminomethylphosphonic acid (AMPA), and glufosinate in water. It was was validated to demonstrate the method detection levels (MDL), compare isotope dilution to standard addition, and evaluate method and compound stability. The original method USGS analytical method 0-2136-01 was developed using liquid chromatography/mass spectrometry and quantitation by standard addition. Lower method detection levels and increased specificity were achieved in the modified method, 0-2141-09, by using liquid chromatography/tandem mass spectrometry (LC/MS/MS). The use of isotope dilution for glyphosate and AMPA and pseudo isotope dilution of glufosinate in place of standard addition was evaluated. Stable-isotope labeled AMPA and glyphosate were used as the isotope dilution standards. In addition, the stability of glyphosate and AMPA was studied in raw filtered and derivatized water samples. The stable-isotope labeled glyphosate and AMPA standards were added to each water sample and the samples then derivatized with 9-fluorenylmethylchloroformate. After derivatization, samples were concentrated using automated online solid-phase extraction (SPE) followed by elution in-line with the LC mobile phase; the compounds separated and then were analyzed by LC/MS/MS using electrospray ionization in negative-ion mode with multiple-reaction monitoring. The deprotonated derivatized parent molecule and two daughter-ion transition pairs were identified and optimized for glyphosate, AMPA, glufosinate, and the glyphosate and AMPA stable-isotope labeled internal standards. Quantitative comparison between standard addition and isotope dilution was conducted using 473 samples analyzed between April 2004 and June 2006. The mean percent difference and relative standard deviation between the two quantitation methods was 7.6 plus or minus 6.30 (n = 179), AMPA 9.6 plus or minus 8.35 (n = 206), and glufosinate 9.3 plus or minus 9.16 (n = 16). The analytical variation of the method, comparison of quantitation by isotope dilution and multipoint linear regressed standard curves, and method detection levels were evaluated by analyzing six sets of distilled-water, groundwater, and surface-water samples spiked in duplicate at 0.0, 0.05, 0.10 and 0.50 microgram per liter and analyzed on 6 different days during 1 month. The grand means of the normalized concentration percentage recovery for glyphosate, AMPA, and glufosinate among all three matrices and spiked concentrations ranged from 99 to 114 plus or minus 2 to 7 percent of the expected spiked concentration. The grand mean of the percentage difference between concentrations calculated by standard addition and linear regressed multipoint standard curves ranged from 8 to 15 plus or minus 2 to 9 percent for the three compounds. The method reporting levels calculated from all the 0.05- microgram per liter spiked samples were 0.02 microgram per liter for all three compounds. Compound stability experiments were conducted on 10 samples derivatized four times for periods between 136 to 269 days. The glyphosate and AMPA concentrations remained relatively constant in samples held up to 136 days before derivatization. The half life of glyphosate varied from 169 to 223 days in the underivatized samples. Derivatized samples were analyzed the day after derivitization, and again 54 and 64 days after derivatization. The derivatized samples analyzed at days 52 and 64 were within 20 percent of the concentrations of the derivatized samples analyzed the day after derivatization.
Research of test fault diagnosis method for micro-satellite PSS
NASA Astrophysics Data System (ADS)
Wu, Haichao; Wang, Jinqi; Yang, Zhi; Yan, Meizhi
2017-11-01
Along with the increase in the number of micro-satellite and the shortening of the product's lifecycle, negative effects of satellite ground test failure become more and more serious. Real-time and efficient fault diagnosis becomes more and more necessary. PSS plays an important role in the satellite ground test's safety and reliability as one of the most important subsystems that guarantees the safety of micro-satellite energy. Take test fault diagnosis method of micro-satellite PSS as research object. On the basis of system features of PSS and classic fault diagnosis methods, propose a kind of fault diagnosis method based on the layered and loose coupling way. This article can provide certain reference for fault diagnosis methods research of other subsystems of micro-satellite.
Enhancements of Nucleate Boiling Under Microgravity Conditions
NASA Technical Reports Server (NTRS)
Zhang, Nengli; Chao, David F.; Yang, W. J.
2000-01-01
This paper presents two means for enhancing nucleate boiling and critical heat flux under microgravity conditions: using micro-configured metal-graphite composites as the boiling surface and dilute aqueous solutions of long-chain alcohols as the working fluid. In the former, thermocapillary force induced by temperature difference between the graphite-fiber tips and the metal matrix plays an important role in bubble detachment. Thus boiling-heat transfer performance does not deteriorate in a reduced-gravity environment. In the latter cases, the surface tension-temperature gradient of the long-chain alcohol solutions turns positive as the temperature exceeds a certain value. Consequently, the Marangoni effect does not impede, but rather aids in bubble departure from the heating surface. This feature is most favorable in microgravity. As a result, the bubble size of departure is substantially reduced at higher frequencies. Based on the existing experimental data, and a two-tier theoretical model, correlation formulas are derived for nucleate boiling on the copper-graphite and aluminum-graphite composite surfaces, in both the isolated and coalesced bubble regimes. In addition, performance equations for nucleate boiling and critical heat flux in dilute aqueous solutions of long-chain alcohols are obtained.
Narayanan, Amal; Chandel, Shubham; Ghosh, Nirmalya; De, Priyadarsi
2015-09-15
Probing volume phase transition behavior of superdiluted polymer solutions both micro- and macroscopically still persists as an outstanding challenge. In this regard, we have explored 4 × 4 spectral Mueller matrix measurement and its inverse analysis for excavating the microarchitectural facts about stimuli responsiveness of "smart" polymers. Phase separation behavior of thermoresponsive poly(N-isopropylacrylamide) (PNIPAM) and pH responsive poly(N,N-(dimethylamino)ethyl methacrylate) (PDMAEMA) and their copolymers were analyzed in terms of Mueller matrix derived polarization parameters, namely, depolarization (Δ), diattenuation (d), and linear retardance (δ). The Δ, d, and δ parameters provided useful information on both macro- and microstructural alterations during the phase separation. Additionally, the two step action ((i) breakage of polymer-water hydrogen bonding and (ii) polymer-polymer aggregation) at the molecular microenvironment during the cloud point generation was successfully probed via these parameters. It is demonstrated that, in comparison to the present techniques available for assessing the hydrophobic-hydrophilic switch over of simple stimuli-responsive polymers, Mueller matrix polarimetry offers an important advantage requiring a few hundred times dilute polymer solution (0.01 mg/mL, 1.1-1.4 μM) at a low-volume format.
Generation of diluted magnetic semiconductor nanostructures by pulsed laser ablation in liquid
NASA Astrophysics Data System (ADS)
Savchuk, Ol. A.; Savchuk, A. I.; Stolyarchuk, I. D.; Tkachuk, P. M.; Garasym, V. I.
2015-11-01
Results of study of two members of diluted magnetic semiconductor (DMS) family, namely Cd1-xMnxTe and Zn1-xMnxO, which are in form of micro- and nanoparticles generated by pulsed laser ablation in liquid medium (PLAL), have been presented. The structural analysis using X-ray diffraction (XRD) of nanocrystals indicated that Mn has entered the AIIBVI lattice without changing the crystal structure and systematically substituted the A2+ ions in the lattice. Atomic force microscopy (AFM) gives information about surface morphology of the formed nanostructures. The scanning electron microscopy (SEM) clearly illustrates flower-like particles of Zn1-xMnxO, which consist of nanosheets and nanoleaves with average thickness about (5-8) nm. Obviously, these nanoobjects are responsible for the observed blue shift of the absorption edge in DMS nanostructures. In magneto-optical Faraday rotation spectra of both Cd1-xMnxTe and Zn1-xMnxO nanostructures there were exhibited peculiarities associated with s,p-d spin exchange interactions and confinement effect. It was observed almost linear dependence of the Faraday rotation as function of magnetic field strength for nanoparticles in contrast to the dependence with saturation in bulk case.
Turick, C.E.; Apel, W.W.
1997-10-28
A method of reducing the concentration of Cr(VI) in a liquid aqueous residue comprises the steps of providing anaerobic Cr(VI) reducing bacteria, mixing the liquid aqueous residue with a nutrient medium to form a mixture, and contacting the mixture with the anaerobic Cr(VI) reducing bacteria such that Cr(VI) is reduced to Cr(III). The anaerobic Cr(VI) reducing bacteria appear to be ubiquitous in soil and can be selected by collecting a soil sample, diluting the soil sample with a sterile diluent to form a diluted sample, mixing the diluted sample with an effective amount of a nutrient medium and an effective amount of Cr(VI) to form a mixture, and incubating the mixture in the substantial absence of oxygen such that growth of Cr(VI) sensitive microorganisms is inhibited and growth of the anaerobic Cr(VI) reducing bacteria is stimulated. A method of in situ bioremediation of Cr(VI) contaminated soil and/or groundwater is also disclosed. 10 figs.
Turick, Charles E.; Apel, William W.
1997-10-28
A method of reducing the concentration of Cr(VI) in a liquid aqueous residue comprises the steps of providing anaerobic Cr(VI) reducing bacteria, mixing the liquid aqueous residue with a nutrient medium to form a mixture, and contacting the mixture with the anaerobic Cr(VI) reducing bacteria such that Cr(VI) is reduced to Cr(III). The anaerobic Cr(VI) reducing bacteria appear to be ubiquitous in soil and can be selected by collecting a soil sample, diluting the soil sample with a sterile diluent to form a diluted sample, mixing the diluted sample with an effective amount of a nutrient medium and an effective amount of Cr(VI) to form a mixture, and incubating the mixture in the substantial absence of oxygen such that growth of Cr(VI) sensitive microorganisms is inhibited and growth of the anaerobic Cr(VI) reducing bacteria is stimulated. A method of in situ bioremediation of Cr(VI) contaminated soil and/or groundwater is also disclosed.
NASA Astrophysics Data System (ADS)
Peña-Vázquez, E.; Barciela-Alonso, M. C.; Pita-Calvo, C.; Domínguez-González, R.; Bermejo-Barrera, P.
2015-09-01
The objective of this work is to develop a method for the determination of metals in saline matrices using high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS). Module SFS 6 for sample injection was used in the manual mode, and flame operating conditions were selected. The main absorption lines were used for all the elements, and the number of selected analytical pixels were 5 (CP±2) for Cd, Cu, Fe, Ni, Pb and Zn, and 3 pixels for Mn (CP±1). Samples were acidified (0.5% (v/v) nitric acid), and the standard addition method was used for the sequential determination of the analytes in diluted samples (1:2). The method showed good precision (RSD(%) < 4%, except for Pb (6.5%)) and good recoveries. Accuracy was checked after the analysis of an SPS-WW2 wastewater reference material diluted with synthetic seawater (dilution 1:2), showing a good agreement between certified and experimental results.
Pulsed Dilution Method for the Recovery of Aggregated Mouse TNF-α.
Mahmoodi, Merat; Ghodsi, Maryam; Moghadam, Malihe; Sankian, Mojtaba
2017-04-01
The expression of mouse tumor necrosis factor alpha (TNF-α) in Escherichia coli is a favorable way to get high yield of protein; however, the formation of cytoplasmic inclusion bodies, which is the consequence of insoluble accumulated proteins, is a major obstacle in this system. To overcome this obstacle, we used a pulsed dilution method to convert the product to its native conformation. Reducing agent and guanidine hydrochloride were used to solubilize inclusion bodies formed after TNF-(α) expression. Then, the refolding procedure was performed by pulsed dilution of the denatured protein into a refolding buffer. The properly-folded protein was purified by metal affinity chromatography. SDS-PAGE showed a 19.9 kDa band related to the mature TNF-(α) protein. The protein was recognized by anti-mouse TNF-(α) on western blots. The final concentration of the purified recombinant TNF-(α) was 62.5 µg/mL. Our study demonstrates the efficiency of this method to produce a high yield of folded mature TNF- (α).
Measurement of LNAPL flow using single-well tracer dilution techniques.
Sale, Tom; Taylor, Geoffrey Ryan; Iltis, Gabriel; Lyverse, Mark
2007-01-01
This paper describes the use of single-well tracer dilution techniques to resolve the rate of light nonaqueous phase liquid (LNAPL) flow through wells and the adjacent geologic formation. Laboratory studies are presented in which a fluorescing tracer is added to LNAPL in wells. An in-well mixer keeps the tracer well mixed in the LNAPL. Tracer concentrations in LNAPL are measured through time using a fiber optic cable and a spectrometer. Results indicate that the rate of tracer depletion is proportional to the rate of LNAPL flow through the well and the adjacent formation. Tracer dilution methods are demonstrated for vertically averaged LNAPL Darcy velocities of 0.00048 to 0.11 m/d and LNAPL thicknesses of 9 to 24 cm. Over the range of conditions studied, results agree closely with steady-state LNAPL flow rates imposed by pumping. A key parameter for estimating LNAPL flow rates in the formation is the flow convergence factor alpha. Measured convergence factors for 0.030-inch wire wrap, 0.030-inch-slotted polyvinyl chloride (PVC), and 0.010-inch-slotted PVC are 1.7, 0.91, and 0.79, respectively. In addition, methods for using tracer dilution data to determine formation transmissivity to LNAPL are presented. Results suggest that single-well tracer dilution techniques are a viable approach for measuring in situ LNAPL flow and formation transmissivity to LNAPL.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beavin, P. Jr.
A previously published method for determining zirconium in antiperspirant aerosols was collaboratively studied by 7 laboratories. The method consists of 2 procedures: a rapid dilution procedure for soluble zirconium compounds or a lengthier fusion procedure for total zirconium followed by colorimetric determination. The collaborators were asked to perform the following: Spiking materials representing 4 levels of soluble zirconium were added to weighed portions of a zirconium-free cream base concentrate and the portions were assayed by the dilution procedure. Spiking materials representing 4 levels of zirconium in either the soluble or the insoluble form (or as a mixture) were also addedmore » to portions of the same concentrate and these portions were assayed by the fusion procedure. They were also asked to concentrate and assay, by both procedures, 2 cans each of 2 commercial aerosol antiperspirants containing zirconyl hydroxychloride. The average percent recoveries and standard deviations for spiked samples were 99.8-100.2 and 1.69-2.71, respectively, for soluble compounds determined by the dilution procedure, and 93.8-97.4 and 3.09-4.78, respectively, for soluble and/or insoluble compounds determined by the fusion procedure. The average perent zirconium found by the dilution procedure in the 2 commercial aerosol products was 0.751 and 0.792. Insufficient collaborative results were received for the fusion procedure for statistical evaluation. The dilution procedure has been adopted as official first action.« less
Development of reproducible assays for polygalacturonase and pectinase.
Li, Qian; Coffman, Anthony M; Ju, Lu-Kwang
2015-05-01
Polygalacturonase and pectinase activities reported in the literature were measured by several different procedures. These procedures do not give comparable results, partly owing to the complexity of the substrates involved. This work was aimed at developing consistent and efficient assays for polygalacturonase and pectinase activities, using polygalacturonic acid and citrus pectin, respectively, as the substrate. Different enzyme mixtures produced by Aspergillus niger and Trichoderma reesei with different inducing carbon sources were used for the method development. A series of experiments were conducted to evaluate the incubation time, substrate concentration, and enzyme dilution. Accordingly, for both assays the recommended (optimal) hydrolysis time is 30min and substrate concentration is 5g/L. For polygalacturonase, the sample should be adjusted to have 0.3-0.8U/mL polygalacturonase activity, because in this range the assay outcomes were consistent (independent of dilution factors). Such a range did not exist for the pectinase assay. The recommended procedure is to assay the sample at multiple (at least 2) dilution factors and determine, by linear interpolation, the dilution factor that would release reducing sugar equivalent to 0.4g/L d-galacturonic acid, and then calculate the activity of the sample accordingly (dilution factor×0.687U/mL). Validation experiments showed consistent results using these assays. Effects of substrate preparation methods were also examined. Copyright © 2015 Elsevier Inc. All rights reserved.
Method of fabricating a micro machine
Stalford, Harold L
2014-11-11
A micro machine may be in or less than the micrometer domain. The micro machine may include a micro actuator and a micro shaft coupled to the micro actuator. The micro shaft is operable to be driven by the micro actuator. A tool is coupled to the micro shaft and is operable to perform work in response to at least motion of the micro shaft.
Methods and systems for micro machines
Stalford, Harold L.
2018-03-06
A micro machine may be in or less than the micrometer domain. The micro machine may include a micro actuator and a micro shaft coupled to the micro actuator. The micro shaft is operable to be driven by the micro actuator. A tool is coupled to the micro shaft and is operable to perform work in response to at least motion of the micro shaft.
Methods and systems for micro machines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stalford, Harold L.
2017-04-11
A micro machine may be in or less than the micrometer domain. The micro machine may include a micro actuator and a micro shaft coupled to the micro actuator. The micro shaft is operable to be driven by the micro actuator. A tool is coupled to the micro shaft and is operable to perform work in response to at least motion of the micro shaft.
Methods and systems for micro machines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stalford, Harold L.
A micro machine may be in or less than the micrometer domain. The micro machine may include a micro actuator and a micro shaft coupled to the micro actuator. The micro shaft is operable to be driven by the micro actuator. A tool is coupled to the micro shaft and is operable to perform work in response to at least motion of the micro shaft.
Method of determining the optimal dilution ratio for fluorescence fingerprint of food constituents.
Trivittayasil, Vipavee; Tsuta, Mizuki; Kokawa, Mito; Yoshimura, Masatoshi; Sugiyama, Junichi; Fujita, Kaori; Shibata, Mario
2015-01-01
Quantitative determination by fluorescence spectroscopy is possible because of the linear relationship between the intensity of emitted fluorescence and the fluorophore concentration. However, concentration quenching may cause the relationship to become nonlinear, and thus, the optimal dilution ratio has to be determined. In the case of fluorescence fingerprint (FF) measurement, fluorescence is measured under multiple wavelength conditions and a method of determining the optimal dilution ratio for multivariate data such as FFs has not been reported. In this study, the FFs of mixed solutions of tryptophan and epicatechin of different concentrations and composition ratios were measured. Principal component analysis was applied, and the resulting loading plots were found to contain useful information about each constituent. The optimal concentration ranges could be determined by identifying the linear region of the PC score plotted against total concentration.
Soleimanpour, Saman; Sedighinia, Fereshteh Sadat; Safipour Afshar, Akbar; Zarif, Reza; Ghazvini, Kiarash
2015-01-01
Objective: In this study, antimicrobial activities of an ethanol extract of Tribulus terrestris aloneand in combination with Capsella bursa-pastoris and Glycyrrhiza glabra were examined in vitro against six pathogens namely Streptococcus mutans, Streptococcus sanguis, Actinomyces viscosus, Enterococcus faecalis Staphylococcus aureus, and Escherichia coli. Materials and methods: Antibacterial activities of the extracts were examined using disc and well diffusion methods and the minimum inhibitory concentration (MIC) and minimum bactericidal concentration (MBC) of ethanol extracts were determined against these microorganisms using agar and broth dilution methods. Chlorhexidine was used as positive control. Results: Tribulus terrestris extract exhibited good antibacterial activity against all bacteria. Antibacterial activity of mixed extract was evaluated and exhibited that mixed extract was more effective against all bacteria than any of the cases alone which indicates the synergistic effect between these three extracts (p˂0.05). No strain showed resistance against these extracts. In agar dilution, Tribulus terrestris exhibited MIC values ranging from 35.0 to 20.0 mg/ml and mixed extract showed MIC values ranging from 12.5 to 5.0 mg/ml. The results of broth dilution method were consistent with the findings of the agar dilution method. Conclusion: This in-vitro study was a preliminary evaluation of antibacterial activity of the plants. It provided scientific evidence to support uses of T. terrestris and its mixture with C. bursa-pastoris and G. glabra for the treatment of oral infections. In-vivo studies are also required to better evaluate the effect of these extracts. PMID:26101754
Diluted magnetic semiconductor nanowires exhibiting magnetoresistance
Yang, Peidong [El Cerrito, CA; Choi, Heonjin [Seoul, KR; Lee, Sangkwon [Daejeon, KR; He, Rongrui [Albany, CA; Zhang, Yanfeng [El Cerrito, CA; Kuykendal, Tevye [Berkeley, CA; Pauzauskie, Peter [Berkeley, CA
2011-08-23
A method for is disclosed for fabricating diluted magnetic semiconductor (DMS) nanowires by providing a catalyst-coated substrate and subjecting at least a portion of the substrate to a semiconductor, and dopant via chloride-based vapor transport to synthesize the nanowires. Using this novel chloride-based chemical vapor transport process, single crystalline diluted magnetic semiconductor nanowires Ga.sub.1-xMn.sub.xN (x=0.07) were synthesized. The nanowires, which have diameters of .about.10 nm to 100 nm and lengths of up to tens of micrometers, show ferromagnetism with Curie temperature above room temperature, and magnetoresistance up to 250 Kelvin.
Micro Dot Patterning on the Light Guide Panel Using Powder Blasting
Jang, Ho Su; Cho, Myeong Woo; Park, Dong Sam
2008-01-01
This study is to develop a micromachining technology for a light guide panel(LGP) mold, whereby micro dot patterns are formed on a LGP surface by a single injection process instead of existing screen printing processes. The micro powder blasting technique is applied to form micro dot patterns on the LGP mold surface. The optimal conditions for masking, laminating, exposure, and developing processes to form the micro dot patterns are first experimentally investigated. A LGP mold with masked micro patterns is then machined using the micro powder blasting method and the machinability of the micro dot patterns is verified. A prototype LGP is test- injected using the developed LGP mold and a shape analysis of the patterns and performance testing of the injected LGP are carried out. As an additional approach, matte finishing, a special surface treatment method, is applied to the mold surface to improve the light diffusion characteristics, uniformity and brightness of the LGP. The results of this study show that the applied powder blasting method can be successfully used to manufacture LGPs with micro patterns by just single injection using the developed mold and thereby replace existing screen printing methods. PMID:27879740
Oxalate Content of Different Drinkable Dilutions of Tea Infusions after Different Brewing Times
Lotfi Yagin, Neda; Mahdavi, Reza; Nikniaz, Zeinab
2012-01-01
Background: The aims of this study were to determine the effect of different brewing times and diluting on oxalate content of loose-packed black teas consumed in Tabriz, Iran. Methods: The oxalate content of black teas after brewing for 5, 10, 15, 30, 60 minutes was measured in triplicate by enzymatic assay. In order to attain the most acceptable dilution of tea infusions, tea samples which were brewed for 15, 30 and 60 minutes were diluted two (120 ml), three (80 ml) and four (60 ml) times respectively. Results: There was a stepwise increase in oxalate concentrations associated with increased brewing times (P< 0.001) with oxalate contents ranging from 4.4 mg/240 ml for the 5 min to 6.3 mg/240 ml for 60 min brewing times, respectively. There were significant differences between the mean oxalate content of different dilutions after brewing for 15, 30 and 60 minutes (P< 0.001). Conclusion: The oxalate content of Iranian consumed black tea after different brewing times and different dilution was below the recommended levels. Therefore, it seems that consumption of black tea several times per day would not pose significant health risk in kidney stone patients and susceptible individuals. PMID:24688937
NASA Astrophysics Data System (ADS)
Chung, Hayoung; Choi, Joonmyung; Yun, Jung-Hoon; Cho, Maenghyo
2016-02-01
A liquid crystal network whose chromophores are functionalized by photochromic dye exhibits light-induced mechanical behaviour. As a result, the micro-scaled thermotropic traits of the network and the macroscopic phase behaviour are both influenced as light alternates the shape of the dyes. In this paper, we present an analysis of this photomechanical behaviour based on the proposed multiscale framework, which incorporates the molecular details of microstate evolution into a continuum-based understanding. The effects of trans-to-cis photoisomerization driven by actinic light irradiation are first examined using molecular dynamics simulations, and are compared against the predictions of the classical dilution model; this reveals certain characteristics of mesogenic interaction upon isomerization, followed by changes in the polymeric structure. We then upscale the thermotropic phase-related information with the aid of a nonlinear finite element analysis; macroscopic deflection with respect to the wide ranges of temperature and actinic light intensity are thereby examined, which reveals that the classical model underestimates the true deformation. This work therefore provides measures for analysing photomechanics in general by bridging the gap between the micro- and macro-scales.
Arsenic compounds as anticancer agents.
Wang, Z Y
2001-08-01
In this paper the use of arsenic compounds as anticancer agents in clinical trials and in in vitro investigations is reviewed, including the experience at our institute. Treatment of newly diagnosed and relapsed patients with acute promyelocytic leukemia (APL) with arsenic trioxide (As2O3) has been found to result in complete remission (CR) rates of 85-93% when given by intravenous infusion for 2-3 h at a dose of 10 mg/day diluted in 5% glucose saline solution. Patients exhibit a response in 28-42 days. CR rates after administration of Composite Indigo Naturalis tablets containing arsenic sulfide and of pure tetraarsenic tetrasulfide reached 98% and 84.9%, respectively. At higher concentrations (1-2 microM), arsenic induced apoptosis, while at lower concentrations (0.1-0.5 microM), it triggered cell differentiation in vitro. As2O3-induced apoptosis has been observed in many cancer cell lines, including esophageal carcinoma, gastric cancer, neuroblastoma, lymphoid malignancies, and multiple myeloma. Its effectiveness was confirmed in the treatment of multiple myeloma. Arsenic compounds are effective agents in the treatment of APL and their activity against other types of cancer requires further investigation.
Stability of parallel electroosmotic flow subject to an axial modulated electric field
NASA Astrophysics Data System (ADS)
Suresh, Vinod; Homsy, George
2001-11-01
The stability of parallel electroosmotic flow in a micro-channel subjected to an AC electric field is studied. A spatially uniform time harmonic electric field is applied along the length of a two-dimensional micro-channel containing a dilute electrolytic solution, resulting in a time periodic parallel flow. The top and bottom walls of the channel are maintained at constant potential. The base state ion concentrations and double layer potential are determined using the Poisson-Boltzmann equation in the Debye-Hückel approximation. Experiments by other workers (Santiago et. al., unpublished) have shown that such a system can exhibit instabilities that take the form of mixing motion occurring in the bulk flow outside the double layer. It is shown that such instabilities can potentially result from the coupling of disturbances in the ion concentrations or electric potential to the base state velocity or ion concentrations, respectively. The stability boundary of the system is determined using Floquet theory and its dependence on the modulation frequency and amplitude of the axial electric field is studied.
TEMORA 1: A new zircon standard for Phanerozoic U-Pb geochronology
Black, L.P.; Kamo, S.L.; Allen, C.M.; Aleinikoff, J.N.; Davis, D.W.; Korsch, R.J.; Foudoulis, C.
2003-01-01
The role of the standard is critical to the derivation of reliable U-Pb zircon ages by micro-beam analysis. For maximum reliability, it is critically important that the utilised standard be homogeneous at all scales of analysis. It is equally important that the standard has been precisely and accurately dated by an independent technique. This study reports the emergence of a new zircon standard that meets those criteria, as demonstrated by Sensitive High Resolution Ion MicroProbe (SHRIMP), isotope dilution thermal ionisation mass-spectrometry (IDTIMS) and excimer laser ablation- inductively coupled plasma-mass-spectrometry (ELA-ICP-MS) documentation. The TEMORA 1 zircon standard derives from the Middledale Gabbroic Diorite, a high-level mafic stock within the Palaeozoic Lachlan Orogen of eastern Australia. Its 206Pb/238U IDTIMS age has been determined to be 416.75??0.24 Ma (95% confidence limits), based on measurement errors alone. Spike-calibration uncertainty limits the accuracy to 416.8??1.1 Ma for U-Pb intercomparisons between different laboratories that do not use a common spike. ?? 2003 Published by Elsevier Science B.V. All rights reserved.
Wetherall, N T; Trivedi, T; Zeller, J; Hodges-Savola, C; McKimm-Breschkin, J L; Zambon, M; Hayden, F G
2003-02-01
The increasing use of influenza virus neuraminidase (NA) inhibitors (NIs) necessitates the development of reliable methods for assessing the NI susceptibility of clinical isolates. We evaluated three NA inhibition assays against a panel of five clinical isolates each of influenza virus A/H1N1, A/H3N2, and B strains and four viruses with a defined resistance genotype (R292K, H274Y, R152K, and E119V). For fluorometric enzyme assay (FA) 1 (FA-1), 2'-(4-methylumbelliferyl)-alpha-D-N-acetylneuraminic acid (MUNANA) at 100 microM was used as the substrate, with pretitration of the virus input. For FA-2, MUNANA at 200 microM was used as the substrate, with a fixed 1:10 dilution of input virus. For the chemiluminescence (CL) assay, the 1,2-dioxetane derivative of sialic acid at 100 microM was used as the substrate, with pretitration of the virus. Four different operators repeated the assays several times in a blinded fashion with both zanamivir and oseltamivir carboxylate (GS4071) to determine intra- and interassay variations. Mean 50% inhibitory concentration (IC(50)) values were lower and generally less variable with the CL assay. FA-1 displayed greater variation than the CL assay or FA-2 and the highest IC(50) values with zanamivir; FA-2 showed the highest values with oseltamivir, particularly for influenza virus B, and was more variable with zanamivir than was the CL assay. All three assays detected 40-fold or greater changes in IC(50) values for the resistant viruses with at least one drug. Mixing experiments, whereby increasing fractions (0, 20, 40, 60, 80, and 100%) of NA from a known NI-resistant virus were mixed with the corresponding NI-sensitive parental NA, indicated that the resolution of IC(50) values was clearer with the CL assay than with FA-2 for two of the resistant variants (R152K and E119V). The FA and CL methods were reliable for the detection of NI resistance, but all assays have certain limitations. Based on reproducibility, ease of automation, time required for the assay, and greater sensitivity, the CL assay was selected for future susceptibility testing of influenza virus isolates circulating globally.
Shen, Ju-fang; Qiu, Hai-bo; Yang, Yi; Liu, Song-qiao; Chen, Yong-ming; Li, Jia-qiong; Wu, Bin; Ding, Hui-min
2006-06-01
To compare the measurement of extra-vascular lung water (EVLW) by a single-indicator dilution technique and measurement obtained by gravimetry in different types of acute respiratory distress syndrome (ARDS). Thirty-three dogs were randomly assigned to three groups: control group, oleic acid group and hydrochloric acid group. ARDS was reproduced by either intravenous injection of oleic acid or intratracheal instillation of hydrochloric acid. EVLW was measured before ARDS, at the onset of ARDS and 10 hours after ARDS by a single indicator dilution technique. Ten hours after ARDS, dogs were sacrificed and then EVLW was quantitated by a gravimetric measurement (golden standard). Hemodynamics and pulmonary gas exchange were determined. There was a close positive correlation (r=0.8820, P<0.05) between single indicator dilution and gravimetric measurements. However, the measurement with the single indicator dilution was consistently higher than the gravimetric measurement. In the control group, there was a positive correlation (r=0.9870, P<0.05) between the values of EVLW as measured by single indicator dilution and by gravimetric measurements. In the oleic acid group, there was also a significant correlation (r=0.9360, P<0.05) between the values of EVLW as measured by single indicator dilution and by gravimetric measurements. In the hydrochloric acid group, correlation (r=0.7950, P<0.05) was also found between EVLW as measured by the two methods. However, the correlation found was lower in the hydrochloric acid group than those in other two groups. Hydrochloric acid instillation resulted in a significant increase in shunting and the partial pressure of carbon dioxide in artery (PaCO(2)) compared with oleic acid group at 10 hours after ARDS. The results of measuring EVLW using single indicator dilution measurement are closely related with those of gravimetric measurement in ARDS, however, the correlations varies with the methods of reproduction of ARDS.
Teoh, Wendy H L; Sia, Alex T H
2003-09-01
We investigated the effect of sequential administration of intrathecal (IT) hyperbaric bupivacaine (after the initial administration of IT hypobaric fentanyl) on the duration of spinal analgesia. Thirty-seven nulliparous parturients with a cervical dilation >/= 5 cm were randomized to receive either IT fentanyl 25 micro g and plain bupivacaine 2.5 mg (group P; n = 19) or IT fentanyl 25 micro g and hyperbaric (with 8% glucose) bupivacaine 2.5 mg (group H; n = 18). The two components of the IT injectate were administered sequentially (fentanyl 25 micro g diluted in 2 mL of normal saline, immediately followed by 0.5 mL of 0.5% bupivacaine). Patients were then positioned with their torso elevated at 30 degrees for 30 min. Pain scores using 0-100 visual analog scales were collected before combined spinal/epidural analgesia and at 5, 15, and 30 min after the block. Patients in Group H had a longer median duration of analgesia (122 min; range, 80-210 min) than Group P (95 min; range, 75-125 min) (P < 0.01). Group H also had a more limited dermatomal spread (median highest sensory level of T8 versus T4 in group P; P < 0.05). The side-effect profile was similar. Under these circumstances, hyperbaric bupivacaine conferred an increased duration of IT analgesia compared with plain bupivacaine.
NASA Astrophysics Data System (ADS)
Brousse, K.; Huang, P.; Pinaud, S.; Respaud, M.; Daffos, B.; Chaudret, B.; Lethien, C.; Taberna, P. L.; Simon, P.
2016-10-01
Carbide derived carbons (CDCs) are promising materials for preparing integrated micro-supercapacitors, as on-chip CDC films are prepared via a process fully compatible with current silicon-based device technology. These films show good adherence on the substrate and high capacitance thanks to their unique nanoporous structure which can be fine-tuned by adjusting the synthesis parameters during chlorination of the metallic carbide precursor. The carbon porosity is mostly related to the synthesis temperature whereas the thickness of the films depends on the chlorination duration. Increasing the pore size allows the adsorption of large solvated ions from organic electrolytes and leads to higher energy densities. Here, we investigated the electrochemical behavior and performance of on-chip TiC-CDC in ionic liquid solvent mixtures of 1-ethyl-3-methylimidazolium tetrafluoroborate (EMIBF4) diluted in either acetonitrile or propylene carbonate via cyclic voltammetry and electrochemical impedance spectroscopy. Thin CDC films exhibited typical capacitive signature and achieved 169 F cm-3 in both electrolytes; 65% of the capacitance was still delivered at 1 V s-1. While increasing the thickness of the films, EMI+ transport limitation was observed in more viscous PC-based electrolyte. Nevertheless, the energy density reached 90 μW h cm-2 in 2M EMIBF4/ACN, confirming the interest of these CDC films for micro-supercapacitors applications.
Dyal, Jonathan; Akampurira, Andrew; Rhein, Joshua; Morawski, Bozena M; Kiggundu, Reuben; Nabeta, Henry W; Musubire, Abdu K; Bahr, Nathan C; Williams, Darlisha A; Bicanic, Tihana; Larsen, Robert A; Meya, David B; Boulware, David R
2016-05-01
Quantitative cerebrospinal fluid (CSF) cultures provide a measure of disease severity in cryptococcal meningitis. The fungal clearance rate by quantitative cultures has become a primary endpoint for phase II clinical trials. This study determined the inter-assay accuracy of three different quantitative culture methodologies. Among 91 participants with meningitis symptoms in Kampala, Uganda, during August-November 2013, 305 CSF samples were prospectively collected from patients at multiple time points during treatment. Samples were simultaneously cultured by three methods: (1) St. George's 100 mcl input volume of CSF with five 1:10 serial dilutions, (2) AIDS Clinical Trials Group (ACTG) method using 1000, 100, 10 mcl input volumes, and two 1:100 dilutions with 100 and 10 mcl input volume per dilution on seven agar plates; and (3) 10 mcl calibrated loop of undiluted and 1:100 diluted CSF (loop). Quantitative culture values did not statistically differ between St. George-ACTG methods (P= .09) but did for St. George-10 mcl loop (P< .001). Repeated measures pairwise correlation between any of the methods was high (r≥0.88). For detecting sterility, the ACTG-method had the highest negative predictive value of 97% (91% St. George, 60% loop), but the ACTG-method had occasional (∼10%) difficulties in quantification due to colony clumping. For CSF clearance rate, St. George-ACTG methods did not differ overall (mean -0.05 ± 0.07 log10CFU/ml/day;P= .14) on a group level; however, individual-level clearance varied. The St. George and ACTG quantitative CSF culture methods produced comparable but not identical results. Quantitative cultures can inform treatment management strategies. © The Author 2016. Published by Oxford University Press on behalf of The International Society for Human and Animal Mycology. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spataru, Sergiu; Hacke, Peter; Sera, Dezso
A method for detecting micro-cracks in solar cells using two dimensional matched filters was developed, derived from the electroluminescence intensity profile of typical micro-cracks. We describe the image processing steps to obtain a binary map with the location of the micro-cracks. Finally, we show how to automatically estimate the total length of each micro-crack from these maps, and propose a method to identify severe types of micro-cracks, such as parallel, dendritic, and cracks with multiple orientations. With an optimized threshold parameter, the technique detects over 90 % of cracks larger than 3 cm in length. The method shows great potentialmore » for quantifying micro-crack damage after manufacturing or module transportation for the determination of a module quality criterion for cell cracking in photovoltaic modules.« less
The optional selection of micro-motion feature based on Support Vector Machine
NASA Astrophysics Data System (ADS)
Li, Bo; Ren, Hongmei; Xiao, Zhi-he; Sheng, Jing
2017-11-01
Micro-motion form of target is multiple, different micro-motion forms are apt to be modulated, which makes it difficult for feature extraction and recognition. Aiming at feature extraction of cone-shaped objects with different micro-motion forms, this paper proposes the best selection method of micro-motion feature based on support vector machine. After the time-frequency distribution of radar echoes, comparing the time-frequency spectrum of objects with different micro-motion forms, features are extracted based on the differences between the instantaneous frequency variations of different micro-motions. According to the methods based on SVM (Support Vector Machine) features are extracted, then the best features are acquired. Finally, the result shows the method proposed in this paper is feasible under the test condition of certain signal-to-noise ratio(SNR).
Noriega-Peláez, Eddy Kei; Mendoza-Muñoz, Néstor; Ganem-Quintanar, Adriana; Quintanar-Guerrero, David
2011-02-01
The essential aim of this article is to prepare solid lipid nanoparticles (SLNs) by emulsification and solvent displacement method and to determine the best process conditions to obtain submicron particles. The emulsification and solvent displacement method is a modification of the well-known emulsification-diffusion method, but without dilution of the system. The extraction of the partially water-miscible solvent from the emulsion globules is carried out under reduced pressure, which causes the diffusion of the solvent toward the external phase, with subsequent lipid aggregation in particles whose size will depend on the process conditions. The critical variables affecting the process, such as stirring rate, the proportion of phases in the emulsion, and the amount of stabilizer and lipid, were evaluated and optimized. By this method, it was possible to obtain a high yield of solids in the dispersion for the lipids evaluated (Compritol(®) ATO 888, Geleol(®), Gelucire(®) 44/14, and stearic acid). SLNs of up to ∼20 mg/mL were obtained for all lipids evaluated. A marked reduction in size, between 500 and 2500 rpm, was seen, and a transition from micro- to nanometric size was observed. The smaller particle sizes obtained were 113 nm for Compritol(®) ATO 888, 70 nm for Gelucire(®) 44/14, 210 nm for Geleol(®), and 527 nm for stearic acid, using a rotor-stator homogenizer (Ultra-Turrax(®)) at 16,000 rpm. The best phase ratio (organic/aqueous) was 1 : 2. The process proposed in this study is a new alternative to prepare SLNs with technological potential.
Ferrone, Vincenzo; Carlucci, Maura; Cotellese, Roberto; Raimondi, Paolo; Cichella, Annadomenica; Marco, Lorenzo Di; Carlucci, Giuseppe
2017-03-01
An ultra high-performance liquid chromatographic (UHPLC) method with PDA detection was developed and validated for the simultaneous quantification of linezolid and ciprofloxacin in human plasma and applied in hospital acquired pneumonia patients (HAP). The method uses a semi-automated microextraction by packed sorbent for sample preparation. All parameters in the extraction step (pH, sample volume, sample dilution and number of aspiration - ejection cycles) and in the desorption step (percentage of acetonitrile in the solvent of elution and number of aspirations of elution solvent through the device) were statistically significant when the recovery was used as response. The method showed good linearity with correlation coefficients, r 2 >0.9995 for the two drugs, as well as high precision (RSD%<9.77% in each case), accuracy ranged from -6.2% to +8.2. The limit of quantification of the two drugs was established at 0.01 and 0.02μg/mL for ciprofloxacin and linezolid, respectively. Linezolid, ciprofloxacin and internal standard were extracted from human plasma with a mean recovery ranging from 92.4% to 97.4%. During validation, the concentrations of linezolid and ciprofloxacin were found to be stable after 3 freeze-thaw cycles and for at least 24h after extraction. This method will subsequently be used to quantify the drugs dosage in patients with HAP to establish if the dosage regimen given is sufficient to eradicate the infection at the target site. Copyright © 2016 Elsevier B.V. All rights reserved.
Martin, B A; Branch, D W; Rodgers, G M
1996-01-01
Increasing dilutions of lupus anticoagulant (LA) plasmas from twelve patients were used to directly compare the sensitivity of four tests for LA. The tests evaluated were the modified Bell and Alton activated partial thromboplastin time (APTT), an APTT using a commercially prepared partial thromboplastin (Platelin LS APTT), a modified dilute Russell's viper venom time (DRVVT), and a modified kaolin clotting time (KCT). LAs were detected in all twelve plasmas by each of three tests and eleven of twelve plasmas in a fourth test when undiluted patient plasma was used. Repeating the tests after diluting the LA plasmas with normal platelet-free plasma (PFP) showed that the KCT was the most sensitive test for LA, detecting eleven of twelve LAs at a dilution of 10% patient plasma and ten of twelve LAs at a dilution of 5% patient plasma. The modified Bell and Alton APTT and the modified DRVVT had similar sensitivities at a patient plasma concentration of 10%, detecting seven of twelve and eight of twelve LAs, respectively. The Platelin LS APTT detected only four of twelve LAs at a patient plasma concentration of 10%. Our results indicate that the modified KCT is a sensitive method for the detection of LAs. The modified Bell and Alton APTT and the DRVVT were less sensitive.
Gluconeogenesis from labeled carbon: estimating isotope dilution
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kelleher, J.K.
1986-03-01
To estimate the rate of gluconeogenesis from steady-state incorporation of labeled 3-carbon precursors into glucose, isotope dilution must be considered so that the rate of labeling of glucose can be quantitatively converted to the rate of gluconeogenesis. An expression for the value of this isotope dilution can be derived using mathematical techniques and a model of the tricarboxylic acid (TCA) cycle. The present investigation employs a more complex model than that used in previous studies. This model includes the following pathways that may affect the correction for isotope dilution: 1) flux of 3-carbon precursor to the oxaloacetate pool via acetyl-CoAmore » and the TCA cycle; 2) flux of 4- or 5-carbon compounds into the TCA cycle; 3) reversible flux between oxaloacetate (OAA) and pyruvate and between OAA and fumarate; 4) incomplete equilibrium between OAA pools; and 5) isotope dilution of 3-carbon tracers between the experimentally measured pool and the precursor for the TCA-cycle OAA pool. Experimental tests are outlined which investigators can use to determine whether these pathways are significant in a specific steady-state system. The study indicated that flux through these five pathways can significantly affect the correction for isotope dilution. To correct for the effects of these pathways an alternative method for calculating isotope dilution is proposed using citrate to relate the specific activities of acetyl-CoA and OAA.« less
Structure of catalase determined by MicroED
Nannenga, Brent L; Shi, Dan; Hattne, Johan; Reyes, Francis E; Gonen, Tamir
2014-01-01
MicroED is a recently developed method that uses electron diffraction for structure determination from very small three-dimensional crystals of biological material. Previously we used a series of still diffraction patterns to determine the structure of lysozyme at 2.9 Å resolution with MicroED (Shi et al., 2013). Here we present the structure of bovine liver catalase determined from a single crystal at 3.2 Å resolution by MicroED. The data were collected by continuous rotation of the sample under constant exposure and were processed and refined using standard programs for X-ray crystallography. The ability of MicroED to determine the structure of bovine liver catalase, a protein that has long resisted atomic analysis by traditional electron crystallography, demonstrates the potential of this method for structure determination. DOI: http://dx.doi.org/10.7554/eLife.03600.001 PMID:25303172
Viveiros, A T; So, N; Komen, J
2000-12-01
Methods for cryopreserving spermatozoa and optimizing sperm:egg dilution ratio in African catfish Clarias gariepinus were developed. Five percent to 25% DMSO and methanol were tested as cryoprotectants, by diluting semen in Ginzburg fish ringer and freezing in 1-milliliter cryovials in a programmable freezer. To avoid an excess of spermatozoa per egg, post-thaw semen was diluted 1:20, 1:200 or 1:2,000 before fertilization. Highest hatching rates were obtained by spermatozoa frozen in 10% methanol and post-thaw diluted to 1:200. Then, slow freezing rates (-2, -5 or -10 degrees C/min) to various endpoint temperatures (range -25 to -70 degrees C) before fast freezing in liquid nitrogen (LN2) were evaluated. Hatching rates equal to control (P > 0.05) were obtained by spermatozoa frozen at -5 degrees C/min to -45 to -50 degrees C and at -10 degrees C/min to -55 degrees C. In 3-step freezing programs, at -5 degrees C/min, the effect of holding spermatozoa for 0, 2 or 5 min at -30, -35 or -40 degrees C before fast freezing in LN2 was analyzed. Hatching rates equal to control (P > 0.05) were produced by spermatozoa frozen to, and held at, -35 degrees C for 5 min and at -40 degrees C for 2 or 5 min. Finally, frozen spermatozoa (10% methanol, -5 degrees C/min, 5-min hold at -40 degrees C, LN2, post-thaw diluted to 1:200) were tested in on-farm fertilization conditions. Again, no difference (P > 0.05) in hatching rate was observed between frozen and fresh spermatozoa. Cryopreservation offers utility as a routine method of sperm storage and management for catfish.
Mielck, F; Bräuer, A; Radke, O; Hanekop, G; Loesch, S; Friedrich, M; Hilgers, R; Sonntag, H
2004-04-01
The transcerebral double-indicator dilution technique is a recently developed method to measure global cerebral blood flow at bedside. It is based on bolus injection of ice-cold indocyanine green dye and simultaneous recording of resulting thermo- and dye-dilution curves in the aorta and the jugular bulb. However, with this method 40 mL of ice-cold solution is administered as a bolus. Therefore, this prospective clinical study was performed to elucidate the effects of repeated administration of indicator on absolute blood temperature and on cerebral blood flow and metabolism. The investigation was performed in nine male patients scheduled for elective coronary artery bypass grafting. Absolute blood temperature was measured in the jugular bulb and in the aorta before and after repeated measurements using the transcerebral double-indicator dilution technique. During the investigated time course, the blood temperature in the jugular bulb, compared to the aorta, was significantly higher with a mean difference of 0.21 degrees C. The administration of an ice-cold bolus reduced the mean blood temperature by 0.06 degrees C in the jugular bulb as well as in the aorta. After the transcerebral double-indicator dilution measurements a temperature recovery to baseline conditions was not observed during the investigated time period. Cerebral blood flow and cerebral metabolism did not change during the investigated time period. Repeated measurements with the transcerebral double-indicator dilution technique do not affect absolute jugular bulb blood temperatures negatively. Global cerebral blood flow and metabolism measurements remain unaltered. However, accuracy and resolution of this technique is not high enough to detect the effect of minor changes of physiological variables.
Micro-Doppler Ambiguity Resolution for Wideband Terahertz Radar Using Intra-Pulse Interference
Yang, Qi; Qin, Yuliang; Deng, Bin; Wang, Hongqiang; You, Peng
2017-01-01
Micro-Doppler, induced by micro-motion of targets, is an important characteristic of target recognition once extracted via parameter estimation methods. However, micro-Doppler is usually too significant to result in ambiguity in the terahertz band because of its relatively high carrier frequency. Thus, a micro-Doppler ambiguity resolution method for wideband terahertz radar using intra-pulse interference is proposed in this paper. The micro-Doppler can be reduced several dozen times its true value to avoid ambiguity through intra-pulse interference processing. The effectiveness of this method is proved by experiments based on a 0.22 THz wideband radar system, and its high estimation precision and excellent noise immunity are verified by Monte Carlo simulation. PMID:28468257
Micro-Doppler Ambiguity Resolution for Wideband Terahertz Radar Using Intra-Pulse Interference.
Yang, Qi; Qin, Yuliang; Deng, Bin; Wang, Hongqiang; You, Peng
2017-04-29
Micro-Doppler, induced by micro-motion of targets, is an important characteristic of target recognition once extracted via parameter estimation methods. However, micro-Doppler is usually too significant to result in ambiguity in the terahertz band because of its relatively high carrier frequency. Thus, a micro-Doppler ambiguity resolution method for wideband terahertz radar using intra-pulse interference is proposed in this paper. The micro-Doppler can be reduced several dozen times its true value to avoid ambiguity through intra-pulse interference processing. The effectiveness of this method is proved by experiments based on a 0.22 THz wideband radar system, and its high estimation precision and excellent noise immunity are verified by Monte Carlo simulation.
Dugdale, A H A; Curtis, G C; Milne, E; Harris, P A; Argo, C Mc
2011-09-01
Excessive accumulations or depletions of body fat have been associated with increased morbidity and mortality in horses and ponies. An objective, minimally-invasive method to accurately quantify body fat in living animals is required to aid nutritional management and define welfare/performance limits. To compare deuterium oxide (D(2) O) dilution-derived estimates of total body water (TBW) and body fat with values obtained by 'gold standard' proximate analysis and cadaver dissection. D(2) O dilution offers a valid method for the determination of TBW and body fat in equids. Seven mature (mean ± s.e. 13 ± 3 years, 212 ± 14 kg, body condition scores 1.25-7/9), healthy, Welsh Mountain pony mares, destined for euthanasia (for nonresearch purposes) were used. Blood samples were collected before and 4 h after D(2) O (0.11-0.13 g/kg bwt, 99.8 atom percent excess) administration. Plasma was analysed by gas isotope ratio mass spectrometry following filtration and zinc reduction. After euthanasia, white adipose tissue (WAT) mass was recorded before all body tissues were analysed by proximate chemical analyses. D(2) O-derived estimates of TBW and body fat were strongly associated with proximate analysis- and dissection-derived values (all r(2) >0.97, P≤0.0001). Bland-Altman analyses demonstrated good agreements between methods. D(2) O dilution slightly overestimated TBW (0.79%, limits of agreement (LoA) -3.75-2.17%) and underestimated total body lipid (1.78%, LoA -0.59-4.15%) and dissected WAT (0.72%, LoA -2.77-4.21%). This study provides the first validation of the D(2) O dilution method for the minimally-invasive, accurate, repeatable and objective measurement of body water and fat in living equids. © 2011 EVJ Ltd.
Regression dilution bias: tools for correction methods and sample size calculation.
Berglund, Lars
2012-08-01
Random errors in measurement of a risk factor will introduce downward bias of an estimated association to a disease or a disease marker. This phenomenon is called regression dilution bias. A bias correction may be made with data from a validity study or a reliability study. In this article we give a non-technical description of designs of reliability studies with emphasis on selection of individuals for a repeated measurement, assumptions of measurement error models, and correction methods for the slope in a simple linear regression model where the dependent variable is a continuous variable. Also, we describe situations where correction for regression dilution bias is not appropriate. The methods are illustrated with the association between insulin sensitivity measured with the euglycaemic insulin clamp technique and fasting insulin, where measurement of the latter variable carries noticeable random error. We provide software tools for estimation of a corrected slope in a simple linear regression model assuming data for a continuous dependent variable and a continuous risk factor from a main study and an additional measurement of the risk factor in a reliability study. Also, we supply programs for estimation of the number of individuals needed in the reliability study and for choice of its design. Our conclusion is that correction for regression dilution bias is seldom applied in epidemiological studies. This may cause important effects of risk factors with large measurement errors to be neglected.
Riley, Paul W.; Gallea, Benoit; Valcour, Andre
2017-01-01
Background: Testing coagulation factor activities requires that multiple dilutions be assayed and analyzed to produce a single result. The slope of the line created by plotting measured factor concentration against sample dilution is evaluated to discern the presence of inhibitors giving rise to nonparallelism. Moreover, samples producing results on initial dilution falling outside the analytic measurement range of the assay must be tested at additional dilutions to produce reportable results. Methods: The complexity of this process has motivated a large clinical reference laboratory to develop advanced computer algorithms with automated reflex testing rules to complete coagulation factor analysis. A method was developed for autoverification of coagulation factor activity using expert rules developed with on an off the shelf commercially available data manager system integrated into an automated coagulation platform. Results: Here, we present an approach allowing for the autoverification and reporting of factor activity results with greatly diminished technologist effort. Conclusions: To the best of our knowledge, this is the first report of its kind providing a detailed procedure for implementation of autoverification expert rules as applied to coagulation factor activity testing. Advantages of this system include ease of training for new operators, minimization of technologist time spent, reduction of staff fatigue, minimization of unnecessary reflex tests, optimization of turnaround time, and assurance of the consistency of the testing and reporting process. PMID:28706751
Determination of (187)Os in molybdenite by ICP-MS with neutron-induced (186)Os and (188)Os spikes.
Qu, W; Du, A; Zhao, D
2001-10-31
The article describes a method for the determination of (187)Os in molybdenite by isotope dilution inductively coupled plasma-mass spectrometry (ID-ICP-MS) with neutron-induced (186)Os and (188)Os spike. The spike used in the present work was prepared in line with the principle by which artificial nuclides are produced in a nuclear reaction. The concentration and isotopic composition of osmium in the prepared spike were evaluated accurately with the isotope dilution method, using negative thermal ion mass spectrometry (N-TIMS). The advantage of this method is that using (186)Os and (188)Os double spikes can effectively compensate for the mass discrimination effects of ICP-MS. Thus, the common correction practice for mass bias in the isotope dilution method with a single spike is unnecessary. In addition, the method enables one to reduce the determined error arising from instrumental instability. The precision for the (187)Os/((186)Os+(188)Os) ratio was approximately 2% (2sigma, RSD), but in the case of (187)Os/(186)Os, (187)Os/(188)Os and (186)Os/(188)Os, precision ranged from 2.0 to 8% (2sigma, RSD). The results for (187)Os concentration in a molybdenite sample determined with this method showed good agreement with reference values.
Trace determination of zinc by substoichiometric isotope dilution analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandhya, D.; Priya, S.; Subramanian, M.O.S.
1996-09-01
A radiometric method based on substoichiometric isotope dilution analysis using 1,10-phenanthroline and a substoichiometric amount of eosin was developed for determining trace amounts of zinc. Evaluation of various metal ion interferences shows that as little as 0.2 {mu}g Zn could be determined in an aqueous-phase volume of 60 mL. The method has been successfully applied to the determination of Zn in city waste incineration ash, cadmium metal, Fourts-B tablets, Boro-plus ointment, and magnesium alloy samples. 12 refs., 3 figs., 3 tabs.
NASA Astrophysics Data System (ADS)
Choi, Jongchan; Lee, Kyeong-Hwan; Yang, Sung
2011-09-01
This note presents a simple fabrication process for patterning micro through-holes in a PDMS layer by a combination of the micromolding in capillaries (MIMIC) method and the surface treatment by atmospheric-pressure CH4/He RF plasma. The fabrication process is confirmed by forming micro through-holes with various shapes including circle, C-shape, open microfluidic channel and hemisphere. All micro through-holes of various shapes in a wide range of diameters and heights are well fabricated by the proposed method. Also, a 3D micromixer containing a PDMS micro through-hole layer formed by the proposed method is built and its performance is tested as another practical demonstration of the proposed fabrication method. Therefore, we believe that the proposed fabrication process will build a PDMS micro through-hole layer in a simple and easy way and will contribute to developing highly efficient multi-layered microfluidic systems, which may require PDMS micro through-hole layers.
NASA Astrophysics Data System (ADS)
Suzuki, Hirofumi; Kawamori, Ryota; Yamamoto, Yuji; Miyabara, Mitsuru; Okino, Tadashi; Hijikata, Yoshio; Moriwaki, Toshimichi
2005-05-01
Micro aspherical glass lenses are required for electronic devices, optical devices and advanced optical fiber transmission equipments. The glass lenses are manufactured by glass molding method by using micro ceramics dies such as tungsten carbide or silicon carbide (1). Therefore molding dies are most important and they were ground by ultra-precision grinding method with diamond wheel. Recently, the wavelength of used laser is becoming shorter and then the accuracies of the micro molding die are required to be much more precise (2). In this paper, ultrasonic assisted polishing methods/systems were developed in order to finish micro aspherical dies that were ground with micro diamond wheel. In the polishing experiments, the molding die of tungsten carbide was polished with diamond abrasives to test the basic polishing characteristics and the aspheric die was polished with proposed ultrasonic assisted polishing method.
40 CFR Appendix B to Part 80 - Test Methods for Lead in Gasoline
Code of Federal Regulations, 2014 CFR
2014-07-01
... one liter. 4.6 Iodine Solution—Dissolve and dilute 3.0 g iodine crystals with Toluene to 100 ml. 4.7...): Dissolve and dilute 3.0 g iodine crystals (American Chemical Society) with toluene (Burdick & Jackson Lab... and aligned according to Section 7 and the instrument has had substantial time for warm-up. 8.2Auto...
40 CFR Appendix B to Part 80 - Test Methods for Lead in Gasoline
Code of Federal Regulations, 2010 CFR
2010-07-01
... one liter. 4.6 Iodine Solution—Dissolve and dilute 3.0 g iodine crystals with Toluene to 100 ml. 4.7...): Dissolve and dilute 3.0 g iodine crystals (American Chemical Society) with toluene (Burdick & Jackson Lab... and aligned according to Section 7 and the instrument has had substantial time for warm-up. 8.2Auto...
40 CFR Appendix B to Part 80 - Test Methods for Lead in Gasoline
Code of Federal Regulations, 2013 CFR
2013-07-01
... one liter. 4.6 Iodine Solution—Dissolve and dilute 3.0 g iodine crystals with Toluene to 100 ml. 4.7...): Dissolve and dilute 3.0 g iodine crystals (American Chemical Society) with toluene (Burdick & Jackson Lab... and aligned according to Section 7 and the instrument has had substantial time for warm-up. 8.2Auto...
40 CFR Appendix B to Part 80 - Test Methods for Lead in Gasoline
Code of Federal Regulations, 2011 CFR
2011-07-01
... one liter. 4.6 Iodine Solution—Dissolve and dilute 3.0 g iodine crystals with Toluene to 100 ml. 4.7...): Dissolve and dilute 3.0 g iodine crystals (American Chemical Society) with toluene (Burdick & Jackson Lab... and aligned according to Section 7 and the instrument has had substantial time for warm-up. 8.2Auto...
40 CFR Appendix B to Part 80 - Test Methods for Lead in Gasoline
Code of Federal Regulations, 2012 CFR
2012-07-01
... one liter. 4.6 Iodine Solution—Dissolve and dilute 3.0 g iodine crystals with Toluene to 100 ml. 4.7...): Dissolve and dilute 3.0 g iodine crystals (American Chemical Society) with toluene (Burdick & Jackson Lab... and aligned according to Section 7 and the instrument has had substantial time for warm-up. 8.2Auto...
NASA Astrophysics Data System (ADS)
Fu, Yu-Hang; Bai, Lin; Luo, Kai-Hong; Jin, Yong; Cheng, Yi
2017-04-01
In this work, we propose a general approach for modeling mass transfer and reaction of dilute solute(s) in incompressible three-phase flows by introducing a collision operator in lattice Boltzmann (LB) method. An LB equation was used to simulate the solute dynamics among three different fluids, in which the newly expanded collision operator was used to depict the interface behavior of dilute solute(s). The multiscale analysis showed that the presented model can recover the macroscopic transport equations derived from the Maxwell-Stefan equation for dilute solutes in three-phase systems. Compared with the analytical equation of state of solute and dynamic behavior, these results are proven to constitute a generalized framework to simulate solute distributions in three-phase flows, including compound soluble in one phase, compound adsorbed on single-interface, compound in two phases, and solute soluble in three phases. Moreover, numerical simulations of benchmark cases, such as phase decomposition, multilayered planar interfaces, and liquid lens, were performed to test the stability and efficiency of the model. Finally, the multiphase mass transfer and reaction in Janus droplet transport in a straight microchannel were well reproduced.
Zhang, Yan; Liu, Jun W; Zheng, Wen J; Wang, Lei; Zhang, Hong Y; Fang, Guo Z; Wang, Shuo
2008-02-01
In this study, an enzyme-linked immunosorbent assay (ELISA) was optimized and applied to the determination of endosulfan residues in 20 different kinds of food commodities including vegetables, dry fruits, tea and meat. The limit of detection (IC(15)) was 0.8 microg kg(-1) and the sensitivity (IC(50)) was 5.3 microg kg(-1). Three simple extraction methods were developed, including shaking on the rotary shaker at 250 r min(-1) overnight, shaking on the rotary shaker for 1 h and thoroughly mixing for 2 min. Methanol was used as the extraction solvent in this study. The extracts were diluted in 0.5% fish skin gelatin (FG) in phosphate-buffered saline (PBS) at various dilutions in order to remove the matrix interference. For cabbage (purple and green), asparagus, Japanese green, Chinese cabbage, scallion, garland chrysanthemum, spinach and garlic, the extracts were diluted 10-fold; for carrots and tea, the extracts were diluted 15-fold and 900-fold, respectively. The extracts of celery, adzuki beans and chestnuts, were diluted 20-fold to avoid the matrix interference; ginger, vegetable soybean and peanut extracts were diluted 100-fold; mutton and chicken extracts were diluted 10-fold and for eel, the dilution was 40-fold. Average recoveries were 63.13-125.61%. Validation was conducted by gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS). The results of this study will be useful to the wide application of an ELISA for the rapid determination of pesticides in food samples.
Urbán, Edit; Terhes, Gabriella; Radnai, Márta; Gorzó, István; Nagy, Elisabeth
2010-06-01
To culture facultative and strict anaerobic bacteria is a well-established method for analyzing subgingival plaque samples. Micro-IDent and micro-IDent Plus (HAIN Lifescience GmbH, Nehren, Germany) tests are two commercially available rapid PCR-based methods for the identification and quantification of putative periodontopathogen bacteria. In this study, we compared these commercial PCR-based hybridization methods with conventional anaerobic culture technique. A total of 36 subgingival plaque samples were collected from periodontal pockets of pregnant women with chronic localized periodontitis. Aliquots of these samples were evaluated with species-specific probes provided by micro-IDent and micro-IDent Plus tests simultaneously, and from the same samples anaerobic and capnophylic bacteria were cultured on selective media. The overall agreement between both methods was excellent for Eubacterium nodatum, Tannerella forsythia and Porphyromonas gingivalis (97-92%), fair for Capnocytophaga sp, Eikenella corrodens, Actinobacillus actinomycetemcomitans, and Prevotella intermedia (91-89%) and poor for Fusobacterium nucleatum, Parvimonas micra (Micromonas micros), and Campylobacter rectus (86-78%). Discrepancies in the results may be explained by inability of culture method to distinguish between closely related taxa (e.i P. intermedia/Prevotella. nigrescens), and problems of keeping periodontopathogen bacteria viable, which is required for successful detection by standard culture method. Nucleic acid-based methods may replace cultivation method as frequently used methods in microbiological diagnosis of progressive periodontitis, thus micro-IDent and micro-IDent Plus tests can be recommended where culture of periodontopathogenic bacteria is not performed in routine microbiology laboratories to analyze subgingival plaque samples. 2010 Elsevier Ltd. All rights reserved.
Stability of florfenicol in drinking water.
Hayes, John M; Eichman, Jonathan; Katz, Terry; Gilewicz, Rosalia
2003-01-01
Florfenicol, a broad-spectrum antibiotic, is being developed for veterinary application as an oral concentrate intended for dilution with drinking water. When a drug product is dosed via drinking water in a farm setting, a number of variables, including pH, chlorine content, hardness of the water used for dilution, and container material, may affect its stability, leading to a decrease in drug potency. The stability of florfenicol after dilution of Florfenicol Drinking Water Concentrate Oral Solution, 23 mg/mL, with drinking water was studied. A stability-indicating, validated liquid chromatographic method was used to evaluate florfenicol stability at 25 degrees C at 5, 10, and 24 h after dilution. The results indicate that florfenicol is stable under a range of simulated field conditions, including various pipe materials and conditions of hard or soft and chlorinated or nonchlorinated water at low or high pH. Significant degradation (> 10%) was observed only for isolated combinations in galvanized pipes. Analysis indicated that the florfenicol concentration in 8 of the 12 water samples stored in galvanized pipes remained above 90% of the initial concentration (100 mg/L) for 24 h after dilution.
Methods and systems for positioning micro elements
Stalford, Harold L
2015-04-28
A micro device may comprise a substrate, a first micro structure coupled to the substrate, a second micro structure coupled to the substrate, and port configured to receive an input. The first micro structure is configured to move into engagement with the second micro structure in response to the input.
Frojmovic, M. M.; Mooney, R. F.; Wong, T.
1994-01-01
We have previously reported that maximal platelet activation with adenosine diphosphate (100 microM ADP) causes rapid expression of all GPIIb-IIIa receptors for fibrinogen (FgR) (< 1-3 s), measured with FITC-labeled PAC1 by flow cytometry. We have extended these studies to examine the effects of ADP concentration on the graded expression and Fg occupancy of GPIIb-IIIa receptors. Human citrated platelet-rich plasma, diluted 10-fold with Walsh-albumin-Mg+2 (2 mM), was treated with ADP (0.1-100 microM). The rates of GPIIb-IIIa receptor expression or Fg binding were measured in unstirred samples by flow cytometry, using FITC-labeled monoclonal antibodies (mAb) PAC1 and 9F9, respectively, from on-rates, using increasing times between mAb and ADP additions. Fibrinogen receptors were all expressed rapidly at low (1 microM) or high (100 microM) ADP (few seconds), whereas Fg occupancy was 50% of maximal by about 2 min. The maximal extent of GPIIb-IIIa receptor expression and Fg occupancy was determined from maximal binding (Flmax) at 30 min incubation with PAC1 or 9F9. On-rates and maximal extents of binding for either PAC1 or 9F9 probes showed identical [ADP]-response profiles ("KD" approximately 1.4 +/- 0.1 microM). However, Flmax studies showed bimodal histograms consisting of "resting" (Po) and maximally "activated" (P*) platelets for both PAC1 and 9F9 binding, with the fraction of "activated" platelets increasing with ADP concentration. The data best fit a model where platelet subpopulations are "quantally" transformed from Po to P*, expressing all GPIIb-IIIa receptors, rapidly filled by Fg, but "triggered" at critical ADP concentrations. Larger, but not the largest, platelets appear to be the most sensitive subpopulation. The implications for clinical studies are discussed, and the relationship to dynamics of aggregation are described in a companion paper. PMID:7858143
Soleimanpour, Saman; Sedighinia, Fereshteh Sadat; Safipour Afshar, Akbar; Zarif, Reza; Ghazvini, Kiarash
2015-01-01
In this study, antimicrobial activities of an ethanol extract of Tribulus terrestris aloneand in combination with Capsella bursa-pastoris and Glycyrrhiza glabra were examined in vitro against six pathogens namely Streptococcus mutans, Streptococcus sanguis, Actinomyces viscosus, Enterococcus faecalis Staphylococcus aureus, and Escherichia coli. Antibacterial activities of the extracts were examined using disc and well diffusion methods and the minimum inhibitory concentration (MIC) and minimum bactericidal concentration (MBC) of ethanol extracts were determined against these microorganisms using agar and broth dilution methods. Chlorhexidine was used as positive control. Tribulus terrestris extract exhibited good antibacterial activity against all bacteria. Antibacterial activity of mixed extract was evaluated and exhibited that mixed extract was more effective against all bacteria than any of the cases alone which indicates the synergistic effect between these three extracts (p˂0.05). No strain showed resistance against these extracts. In agar dilution, Tribulus terrestris exhibited MIC values ranging from 35.0 to 20.0 mg/ml and mixed extract showed MIC values ranging from 12.5 to 5.0 mg/ml. The results of broth dilution method were consistent with the findings of the agar dilution method. This in-vitro study was a preliminary evaluation of antibacterial activity of the plants. It provided scientific evidence to support uses of T. terrestris and its mixture with C. bursa-pastoris and G. glabra for the treatment of oral infections. In-vivo studies are also required to better evaluate the effect of these extracts.
Short-term landfill methane emissions dependency on wind.
Delkash, Madjid; Zhou, Bowen; Han, Byunghyun; Chow, Fotini K; Rella, Chris W; Imhoff, Paul T
2016-09-01
Short-term (2-10h) variations of whole-landfill methane emissions have been observed in recent field studies using the tracer dilution method for emissions measurement. To investigate the cause of these variations, the tracer dilution method is applied using 1-min emissions measurements at Sandtown Landfill (Delaware, USA) for a 2-h measurement period. An atmospheric dispersion model is developed for this field test site, which is the first application of such modeling to evaluate atmospheric effects on gas plume transport from landfills. The model is used to examine three possible causes of observed temporal emissions variability: temporal variability of surface wind speed affecting whole landfill emissions, spatial variability of emissions due to local wind speed variations, and misaligned tracer gas release and methane emissions locations. At this site, atmospheric modeling indicates that variation in tracer dilution method emissions measurements may be caused by whole-landfill emissions variation with wind speed. Field data collected over the time period of the atmospheric model simulations corroborate this result: methane emissions are correlated with wind speed on the landfill surface with R(2)=0.51 for data 2.5m above ground, or R(2)=0.55 using data 85m above ground, with emissions increasing by up to a factor of 2 for an approximately 30% increase in wind speed. Although the atmospheric modeling and field test are conducted at a single landfill, the results suggest that wind-induced emissions may affect tracer dilution method emissions measurements at other landfills. Copyright © 2016 Elsevier Ltd. All rights reserved.
Raeisi, Javad; Saifi, Mahnaz; Pourshafie, Mohammad Reza; Habibi, Mehri; Mohajerani, Hamid Reza; Akbari, Neda
2017-01-01
Introduction Vancomycin Resistant Enterococci (VRE) can be found all over the world. Thus, rapid detection of the isolates could be of high importance in the treatment or prevention of the associated disease. Aim To measure the turanose fermentation in Enterococcus faecalis clinical isolates for rapid differentiation of VRE and Vancomycin-Susceptible E. faecalis (VSE) isolates. Materials and Methods Forty E. faecalis samples were isolated from 200 clinical samples in Tehran Medical Center, Iran, from October 2012 to December 2012. These isolates were detected according to the standard microbial and biochemical tests. Detection of VRE isolates was originally performed by disk diffusion using 1 μg vancomycin disk, followed by Polymerase Chain Reaction (PCR) amplification of the vanA gene. Finally, the turanose consumption in 1%, 0.7% and 0.5% dilutions was detected by a phenotypic method. Results Among the 40 E. faecalis isolates, 20 vancomycin-susceptible and 20 vancomycin-resistant E. faecalis were isolated according to the disk diffusion and PCR of the vanA gene. There was a considerable difference between VRE and VSE isolates in 0.7% dilution of turanose. However, there was no significant difference between VRE and VSE in 1% and 0.5% dilutions of turanose. Conclusion Since detection of VRE isolates is of high importance, especially in nosocomial infections, phenotypic methods may be highly useful for this purpose. In conclusion, our data indicate that VRE isolated from clinical samples could be distinguished from VSE isolates by turanose fermentation at dilution 0.7%. PMID:28511382
Yang, Qi; Franco, Christopher M M; Zhang, Wei
2015-10-01
Experiments were designed to validate the two common DNA extraction protocols (CTAB-based method and DNeasy Blood & Tissue Kit) used to effectively recover actinobacterial DNA from sponge samples in order to study the sponge-associated actinobacterial diversity. This was done by artificially spiking sponge samples with actinobacteria (spores, mycelia and a combination of the two). Our results demonstrated that both DNA extraction methods were effective in obtaining DNA from the sponge samples as well as the sponge samples spiked with different amounts of actinobacteria. However, it was noted that in the presence of the sponge, the bacterial 16S rRNA gene could not be amplified unless the combined DNA template was diluted. To test the hypothesis that the extracted sponge DNA contained inhibitors, dilutions of the DNA extracts were tested for six sponge species representing five orders. The results suggested that the inhibitors were co-extracted with the sponge DNA, and a high dilution of this DNA was required for the successful PCR amplification for most of the samples. The optimized PCR conditions, including primer selection, PCR reaction system and program optimization, further improved the PCR performance. However, no single PCR condition was found to be suitable for the diverse sponge samples using various primer sets. These results highlight for the first time that the DNA extraction methods used are effective in obtaining actinobacterial DNA and that the presence of inhibitors in the sponge DNA requires high dilution coupled with fine tuning of the PCR conditions to achieve success in the study of sponge-associated actinobacterial diversity.
Zhang, Hongyan; Wang, Lei; Zhang, Yan; Fang, Guozhen; Zheng, Wenjie; Wang, Shuo
2007-03-21
Direct competitive enzyme-linked immunosorbent assays (ELISA) were developed to detect a broad range of sulfonamides in various matrices. Screening for this class of antibiotics in pig muscle, chicken muscle, fish, and egg extracts was accomplished by simple, rapid extraction methods carried out with only phosphate-buffered saline (PBS) buffer. Twenty milliliters of extract solution was added to 4 g of sample to extract the sulfonamide residues, and sample extracts diluted with assay buffer were directly analyzed by ELISA; matrix effects could be avoided with 1:5 dilution of pig muscle, chicken muscle, and egg extracts with PBS and 1:5 dilution of fish extract with 1% bovine serum albumin (BSA)-PBS. For liver sample, the extraction method was a little more complicated; 2 g of sample was added to 20 mL of ethanol, mixed, and then centrifuged. The solvent of 10 mL of the upper liquid was removed, and the residues were dissolved in 10 mL of PBS and then filtered; the filtrate was diluted two-fold with 0.5% BSA-PBS for ELISA. These common methods were able to detect seven sulfonamide residues such as sulfisozole, sulfathiazole, sufameter, sulfamethoxypyridazine, sulfapyridine, sulfamethizole, and sulfachlorpyridazine in pig muscle, liver, chicken muscle, egg, and fish. The assay's detection limits for these compounds were less than 100 microg kg-1. Various extraction methods were tested, and the average recovery (n=3) of 100 microg kg-1 for the matrices was found to range from 77.3 to 123.7%.
Mohd Nasir, Mohd Desa; Parasakthi, Navaratnam
2004-06-01
The increasing prevalence of penicillin-resistant Streptococuus pneumoniae urges for fast and accurate susceptibility testing methods. This study evaluated the comparability of three commonly used techniques; disk diffusion, E-test and agar dilution, to detect penicillin susceptibility in clinical isolates of S. pneumoniae. Fifty pneumococcal isolates, obtained from patients at the University of Malaya Medical Centre, were selected to include both penicillin-susceptible strains and those that had decreased susceptibility (resistant and intermediate) to penicillin. The minimum inhibitory concentration (MIC) values of penicillin to serve as the reference was determined by the agar dilution method in which, based on the MIC breakpoints recommended by the National Committee for Clinical Laboratory Standards (NCCLS), 27 strains had decreased susceptibility to penicillin with 17 strains resistant and 10 intermediate. Comparing to the agar dilution method, oxacillin disk diffusion test detected all strains with decreased penicillin susceptibility as such while E-test showed a close agreement of susceptibility (92%) of the isolates to penicillin. This confirmed that oxacillin is a good screening test for S. pneumoniae isolates with decreased susceptibility to penicillin while E-test is very reliable for rapid and accurate detection of penicillin susceptibility.
Domain Regeneration for Cross-Database Micro-Expression Recognition
NASA Astrophysics Data System (ADS)
Zong, Yuan; Zheng, Wenming; Huang, Xiaohua; Shi, Jingang; Cui, Zhen; Zhao, Guoying
2018-05-01
In this paper, we investigate the cross-database micro-expression recognition problem, where the training and testing samples are from two different micro-expression databases. Under this setting, the training and testing samples would have different feature distributions and hence the performance of most existing micro-expression recognition methods may decrease greatly. To solve this problem, we propose a simple yet effective method called Target Sample Re-Generator (TSRG) in this paper. By using TSRG, we are able to re-generate the samples from target micro-expression database and the re-generated target samples would share same or similar feature distributions with the original source samples. For this reason, we can then use the classifier learned based on the labeled source samples to accurately predict the micro-expression categories of the unlabeled target samples. To evaluate the performance of the proposed TSRG method, extensive cross-database micro-expression recognition experiments designed based on SMIC and CASME II databases are conducted. Compared with recent state-of-the-art cross-database emotion recognition methods, the proposed TSRG achieves more promising results.
Tang, Yongjiang; Zhang, Mingke; Feng, Yulin; Liang, Binmiao
2016-11-23
Chronic obstructive pulmonary disease (COPD) is a chronic airway disease characterized by persistent airflow limitation. Moreover, lung hyperinflation evaluated by lung volumes is also the key pathophysiologic process during COPD progression. Nevertheless, there is still no preferred method to evaluate lung volumes. For this study, we recruited 170 patients with stable COPD to assess lung volumes stratified by airflow limitation severity. Lung volumes including residual volume (RV) and total lung capacity (TLC) were determined by both body plethysmography and helium dilution methods. The discrepancies between these two methods were recorded as ΔRV%pred, ΔTLC%pred, and ΔRV/TLC. We found that ΔRV%pred, ΔTLC%pred, and ΔRV/TLC increased significantly with the severity of COPD. The differences of lung capacity between these two methods were negatively correlated with FEV 1 %pred, and diffusing capacity for carbon monoxide (D L CO%pred). Moreover, the receiver operating characteristic (ROC) for ΔTLC%pred to distinguish severe COPD from non-severe COPD had an area under curve (AUC) of 0.886. The differences of lung volume parameters measured by body plethysmography and helium dilution methods were associated with airflow limitation and can effectively differentiate COPD severity, which may be a supportive method to assess the lung function of stable COPD patients.
Basu, Sabita; Dhar, Supriya; Mishra, Deepak; Chandy, Mammen
2015-01-01
The ABO blood group system is of prime significance in red cell transfusion and organ transplantation. However, ABO compatibility is not critical in allogenic hemopoietic stem cell transplantation (HSCT) and approximately 40-50% of hemopoietic stem cell transplants are ABO incompatible. This incompatibility may be major, minor or bi-directional. Though there are descriptions of transfusion practice and protocols in ABO incompatible HSCT, there are considerable variations and transfusion support in these patients can be very challenging. The immunohematologic observations in two cases of bi-directional ABO incompatible HSCT have been described, and clinico-serologic correlation has been attempted. In both cases, peripheral blood stem cell harvests were obtained using the Cobe spectra cell separator. Immunohematologic assessments in the donor and recipient were done as a part of pre HSCT evaluation. Both the standard tube technique and column agglutination method (Ortho Biovue Micro Bead System) was used. Antibody screen was done by column agglutination method using three cell panel (Surgiscreen cells). Isoagglutinin titration was done by the master dilution method and standard validated techniques were used. The pattern of laboratory findings in the two cases was different and so were the clinical outcomes. Although there was early engraftment in the first case, the second case developed pure red cell aplasia and this was well-reflected in the immunohematologic assessments. Immunohematologic assessment correlated well with the clinical picture and could be used to predict clinical outcome and onset of complications in ABO incompatible HSCT.
Sharma, Amit Kumar; Gangwar, Mayank; Kumar, Dharmendra; Nath, Gopal; Kumar Sinha, Akhoury Sudhir; Tripathi, Yamini Bhushan
2016-01-01
This study aims to evaluate the antimicrobial activity, phytochemical studies and thin layer chromatography analysis of machine oil, hexane extract of seed oil and methanol extract of presscake & latex of Jatropha curcas Linn (family Euphorbiaceae). J. curcas extracts were subjected to preliminary qualitative phytochemical screening to detect the major phytochemicals followed by its reducing power and content of phenol and flavonoids in different fractions. Thin layer chromatography was also performed using different solvent systems for the analysis of a number of constituents in the plant extracts. Antimicrobial activity was evaluated by the disc diffusion method, while the minimum inhibitory concentration, minimum bactericidal concentration and minimum fungicidal concentration were calculated by micro dilution method. The methanolic fraction of latex and cake exhibited marked antifungal and antibacterial activities against Gram-positive and Gram-negative bacteria. Phytochemical analysis revealed the presence of alkaloids, saponins, tannins, terpenoids, steroids, glycosides, phenols and flavonoids. Reducing power showed dose dependent increase in concentration compared to standard Quercetin. Furthermore, this study recommended the isolation and separation of bioactive compounds responsible for the antibacterial activity which would be done by using different chromatographic methods such as high-performance liquid chromatography (HPLC), GC-MS etc. The results of the above study suggest that all parts of the plants possess potent antibacterial activity. Hence, it is important to isolate the active principles for further testing of antimicrobial and other biological efficacy.
Diagnostic microbiology in veterinary dermatology: present and future.
Guardabassi, Luca; Damborg, Peter; Stamm, Ivonne; Kopp, Peter A; Broens, Els M; Toutain, Pierre-Louis
2017-02-01
The microbiology laboratory can be perceived as a service provider rather than an integral part of the healthcare team. The aim of this review is to discuss the current challenges of providing a state-of-the-art diagnostic veterinary microbiology service including the identification (ID) and antimicrobial susceptibility testing (AST) of key pathogens in veterinary dermatology. The Study Group for Veterinary Microbiology (ESGVM) of the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) identified scientific, technological, educational and regulatory issues impacting the predictive value of AST and the quality of the service offered by microbiology laboratories. The advent of mass spectrometry has significantly reduced the time required for ID of key pathogens such as Staphylococcus pseudintermedius. However, the turnaround time for validated AST methods has remained unchanged for many years. Beyond scientific and technological constraints, AST methods are not harmonized and clinical breakpoints for some antimicrobial drugs are either missing or inadequate. Small laboratories, including in-clinic laboratories, are usually not adequately equipped to run up-to-date clinical microbiologic diagnostic tests. ESGVM recommends the use of laboratories employing mass spectrometry for ID and broth micro-dilution for AST, and offering assistance by expert microbiologists on pre- and post-analytical issues. Setting general standards for veterinary clinical microbiology, promoting antimicrobial stewardship, and the development of new, validated and rapid diagnostic methods, especially for AST, are among the missions of ESGVM. © 2017 The Authors. Veterinary Dermatology published by John Wiley & Sons Ltd on behalf of the ESVD and ACVD.
Wei, Lee Seong; Wee, Wendy
2013-01-01
Background & Objectives This paper describes chemical composition and antimicrobial activity of Cymbopogon nardus citronella essential oil against Edwardsiella spp. (n = 21), Vibrio spp. (n = 6), Aeromonas spp. (n = 2), Escherichia coli (n = 2), Salmonella spp. (n = 2), Flavobacterium spp. (n = 1), Pseudomonas spp. (n = 1) and Streptococcus spp. (n = 1) isolated from internal organs of aquatic animals. Due to the ban of antibiotics for aquaculture use, this study was carried out to evaluate the potential of citronella essential oil as alternative to commercial antibiotic use against systemic bacteria in cultured aquatic animals. Materials & Methods The essential oil of C. nardus was prepared by using the steam distillation method and the chemical composition of the essential oil was analyzed by gas chromatography–mass spectroscopy (GC–MS). Minimum inhibitory concentration (MIC) of the essential oil tested against bacterial isolates from various aquatic animals and ATCC type strains were determined using two-fold broth micro dilution method with kanamycin and eugenol as positive controls. Results A total of 22 chemical compounds were detected in C. nardus essential oil with 6-octenal, 3, 7-dimethyl- or citronellal representing the major compounds (29.6%). The MIC values of the citronella oil ranged from 0.244 µg/ml to 0.977 µg/ml when tested against the bacterial isolates. Conclusion The results of the present study revealed the potential of C. nardus essential oil as alternative to commercial antibiotics for aquaculture use. PMID:23825733
A curved surface micro-moiré method and its application in evaluating curved surface residual stress
NASA Astrophysics Data System (ADS)
Zhang, Hongye; Wu, Chenlong; Liu, Zhanwei; Xie, Huimin
2014-09-01
The moiré method is typically applied to the measurement of deformations of a flat surface while, for a curved surface, this method is rarely used other than for projection moiré or moiré interferometry. Here, a novel colour charge-coupled device (CCD) micro-moiré method has been developed, based on which a curved surface micro-moiré (CSMM) method is proposed with a colour CCD and optical microscope (OM). In the CSMM method, no additional reference grating is needed as a Bayer colour filter array (CFA) installed on the OM in front of the colour CCD image sensor performs this role. Micro-moiré fringes with high contrast are directly observed with the OM through the Bayer CFA under the special condition of observing a curved specimen grating. The principle of the CSMM method based on a colour CCD micro-moiré method and its application range and error analysis are all described in detail. In an experiment, the curved surface residual stress near a welded seam on a stainless steel tube was investigated using the CSMM method.
Assessment of formulas for calculating critical concentration by the agar diffusion method.
Drugeon, H B; Juvin, M E; Caillon, J; Courtieu, A L
1987-01-01
The critical concentration of antibiotic was calculated by using the agar diffusion method with disks containing different charges of antibiotic. It is currently possible to use different calculation formulas (based on Fick's law) devised by Cooper and Woodman (the best known) and by Vesterdal. The results obtained with the formulas were compared with the MIC results (obtained by the agar dilution method). A total of 91 strains and two cephalosporins (cefotaxime and ceftriaxone) were studied. The formula of Cooper and Woodman led to critical concentrations that were higher than the MIC, but concentrations obtained with the Vesterdal formula were closer to the MIC. The critical concentration was independent of method parameters (dilution, for example). PMID:3619419
Peeters, Kelly; Iskra, Jernej; Zuliani, Tea; Ščančar, Janez; Milačič, Radmila
2014-07-01
Organotin compounds (OTCs) are among the most toxic substances ever introduced to the environment by man. They are common pollutants in marine ecosystems, but are also present in the terrestrial environment, accumulated mainly in sewage sludge and landfill leachates. In investigations of the degradation and methylation processes of OTC in environmental samples, the use of enriched isotopic tracers represents a powerful analytical tool. Sn-enriched OTC are also necessary in application of the isotope dilution mass spectrometry technique for their accurate quantification. Since Sn-enriched monobutyltin (MBT), dibutyltin (DBT) and tributyltin (TBT) are not commercially available as single species, "in house" synthesis of individual butyltin-enriched species is necessary. In the present work, the preparation of the most toxic butyltin, namely TBT, was performed via a simple synthetic path, starting with bromination of metallic Sn, followed by butylation with butyl lithium. The tetrabutyltin (TeBT) formed was transformed to tributyltin chloride (TBTCl) using concentrated hydrochloric acid (HCl). The purity of the synthesized TBT was verified by speciation analysis using the techniques of gas chromatography coupled to inductively coupled plasma mass spectrometry (GC-ICP-MS) and nuclear magnetic resonance (NMR). The results showed that TBT had a purity of more than 97%. The remaining 3% corresponded to DBT. TBT was quantified by reverse isotope dilution GC-ICP-MS. The synthesis yield was around 60%. The advantage of this procedure over those previously reported lies in its possibility to be applied on a micro-scale (starting with 10mg of metallic Sn). This feature is of crucial importance, since enriched metallic Sn is extremely expensive. The procedure is simple and repeatable, and was successfully applied for the preparation of (117)Sn-enriched TBTCl from (117)Sn-enriched metal. Copyright © 2014 Elsevier Ltd. All rights reserved.
Henkel, Sebastian G; Ter Beek, Alexander; Steinsiek, Sonja; Stagge, Stefan; Bettenbrock, Katja; de Mattos, M Joost Teixeira; Sauter, Thomas; Sawodny, Oliver; Ederer, Michael
2014-01-01
For adaptation between anaerobic, micro-aerobic and aerobic conditions Escherichia coli's metabolism and in particular its electron transport chain (ETC) is highly regulated. Although it is known that the global transcriptional regulators FNR and ArcA are involved in oxygen response it is unclear how they interplay in the regulation of ETC enzymes under micro-aerobic chemostat conditions. Also, there are diverse results which and how quinones (oxidised/reduced, ubiquinone/other quinones) are controlling the ArcBA two-component system. In the following a mathematical model of the E. coli ETC linked to basic modules for substrate uptake, fermentation product excretion and biomass formation is introduced. The kinetic modelling focusses on regulatory principles of the ETC for varying oxygen conditions in glucose-limited continuous cultures. The model is based on the balance of electron donation (glucose) and acceptance (oxygen or other acceptors). Also, it is able to account for different chemostat conditions due to changed substrate concentrations and dilution rates. The parameter identification process is divided into an estimation and a validation step based on previously published and new experimental data. The model shows that experimentally observed, qualitatively different behaviour of the ubiquinone redox state and the ArcA activity profile in the micro-aerobic range for different experimental conditions can emerge from a single network structure. The network structure features a strong feed-forward effect from the FNR regulatory system to the ArcBA regulatory system via a common control of the dehydrogenases of the ETC. The model supports the hypothesis that ubiquinone but not ubiquinol plays a key role in determining the activity of ArcBA in a glucose-limited chemostat at micro-aerobic conditions.
Ravi, Bolleddu; Chakraborty, Snigdha; Bhattacharjee, Mitradip; Mitra, Shirsendu; Ghosh, Abir; Gooh Pattader, Partho Sarathi; Bandyopadhyay, Dipankar
2017-01-11
Chemical pattern directed spin-dewetting of a macroscopic droplet composed of a dilute organic solution of liquid crystal (LC) formed an ordered array of micro- and nanoscale LC droplets. Controlled evaporation of the spin-dewetted droplets through vacuum drying could further miniaturize the size to the level of ∼90 nm. The size, periodicity, and spacing of these mesoscale droplets could be tuned with the variations in the initial loading of LC in the organic solution, the strength of the centripetal force on the droplet, and the duration of the evaporation. A simple theoretical model was developed to predict the spacing between the spin-dewetted droplets. The patterned LC droplets showed a reversible phase transition from nematic to isotropic and vice versa with the periodic exposure of a solvent vapor and its removal. A similar phase transition behavior was also observed with the periodic increase or reduction of temperature, suggesting their usefulness as vapor or temperature sensors. Interestingly, when the spin-dewetted droplets were confined between a pair of electrodes and an external electric field was applied, the droplets situated at the hydrophobic patches showed light-reflecting properties under the polarization microscopy highlighting their importance in the development of micro- or nanoscale LC displays. The digitized LC droplets, which were stationary otherwise, showed dielectrophoretic locomotion under the guidance of the external electric field beyond a threshold intensity of the field. Remarkably, the motion of these droplets could be restricted to the hydrophilic zones, which were confined between the hydrophobic patches of the chemically patterned surface. The findings could significantly contribute in the development of futuristic vapor or temperature sensors, light reflectors, and self-propellers using the micro- or nanoscale digitized LC droplets.
Peng, Hui; Lan, Chaowang; Zheng, Yi; Hutvagner, Gyorgy; Tao, Dacheng; Li, Jinyan
2017-03-24
MicroRNAs always function cooperatively in their regulation of gene expression. Dysfunctions of these co-functional microRNAs can play significant roles in disease development. We are interested in those multi-disease associated co-functional microRNAs that regulate their common dysfunctional target genes cooperatively in the development of multiple diseases. The research is potentially useful for human disease studies at the transcriptional level and for the study of multi-purpose microRNA therapeutics. We designed a computational method to detect multi-disease associated co-functional microRNA pairs and conducted cross disease analysis on a reconstructed disease-gene-microRNA (DGR) tripartite network. The construction of the DGR tripartite network is by the integration of newly predicted disease-microRNA associations with those relationships of diseases, microRNAs and genes maintained by existing databases. The prediction method uses a set of reliable negative samples of disease-microRNA association and a pre-computed kernel matrix instead of kernel functions. From this reconstructed DGR tripartite network, multi-disease associated co-functional microRNA pairs are detected together with their common dysfunctional target genes and ranked by a novel scoring method. We also conducted proof-of-concept case studies on cancer-related co-functional microRNA pairs as well as on non-cancer disease-related microRNA pairs. With the prioritization of the co-functional microRNAs that relate to a series of diseases, we found that the co-function phenomenon is not unusual. We also confirmed that the regulation of the microRNAs for the development of cancers is more complex and have more unique properties than those of non-cancer diseases.
Formation of nanocrystalline diamond in polymer like carbon films deposited by plasma CVD.
Bhaduri, A; Chaudhuri, P
2009-09-01
Conventional plasma enhanced chemical vapour deposition (PECVD) method is generally not suitable for the growth of nanocrystalline diamond (NCD) films. However, our study shows that conditions favourable for powder formation help to grow large amount of nanocrystallites in conventional PECVD. With CH4 as the carbon source gas, dilution with Ar and moderate (50 W) rf power enhances formations of powders (nanoparticles) and C2 dimers within the plasma. On the other hand, with pure CH4 or with hydrogen diluted CH4, powder formation as also NCD growth is hindered. It is proposed that the nanoparticles formed in the plasma act as the "islands" while the C2 dimers are the "seeds" for the NCD growth. The structure of the films deposited on the grounded anode under different conditions of dilution has been studied. It is observed that with high Ar dilution the films contain NCD embedded in polymer like carbon (PLC) matrix.
Refractometry for quality control of anesthetic drug mixtures.
Stabenow, Jennifer M; Maske, Mindy L; Vogler, George A
2006-07-01
Injectable anesthetic drugs used in rodents are often mixed and further diluted to increase the convenience and accuracy of dosing. We evaluated clinical refractometry as a simple and rapid method of quality control and mixing error detection of rodent anesthetic or analgesic mixtures. Dilutions of ketamine, xylazine, acepromazine, and buprenorphine were prepared with reagent-grade water to produce at least 4 concentration levels. The refraction of each concentration then was measured with a clinical refractometer and plotted against the percentage of stock concentration. The resulting graphs were linear and could be used to determine the concentration of single-drug dilutions or to predict the refraction of drug mixtures. We conclude that refractometry can be used to assess the concentration of dilutions of single drugs and can verify the mixing accuracy of drug combinations when the components of the mixture are known and fall within the detection range of the instrument.
Moderate Dilution of Copper Slag by Natural Gas
NASA Astrophysics Data System (ADS)
Zhang, Bao-jing; Zhang, Ting-an; Niu, Li-ping; Liu, Nan-song; Dou, Zhi-he; Li, Zhi-qiang
2018-01-01
To enable use of copper slag and extract the maximum value from the contained copper, an innovative method of reducing moderately diluted slag to smelt copper-containing antibacterial stainless steel is proposed. This work focused on moderate dilution of copper slag using natural gas. The thermodynamics of copper slag dilution and ternary phase diagrams of the slag system were calculated. The effects of blowing time, temperature, matte settling time, and calcium oxide addition were investigated. The optimum reaction conditions were identified to be blowing time of 20 min, reaction temperature of 1250°C, settling time of 60 min, CaO addition of 4% of mass of slag, natural gas flow rate of 80 mL/min, and outlet pressure of 0.1 MPa. Under these conditions, the Fe3O4 and copper contents of the residue were 7.36% and 0.50%, respectively.
Akilandeswari, K; Ruckmani, K
2016-12-30
Methicillin-resistant Staphylococcus aureus (MRSA) infections are easily spread among infected patients, where resistance has dramatically increased resulted in serious health issues. Therefore, there is a need to develop alternative natural or combination drug therapies. Apigenin (AP) is a natural poly phenolic flavonoid has been found to possess many beneficial biological actions. The aim of this study was to investigate the anti-MRSA efficacy and synergistic effect of apigenin (AP) and in combination with ampicillin (AM) and ceftriaxone (CEF). The antibacterial activity of apigenin was assessed by the broth macro dilution, checkerboard micro dilution method and time-kill assay. The mode of action was studied by outer and inner membrane permeabilisation assays, scanning electron microscopy and transmission electron microscopy. The minimum inhibitory concentration (MIC) of apigenin against gram positive and gram negative strain ranged from 32.5 to 62.5µg/ml. In checkerboard method apigenin markedly reduced the MIC of the antibiotics ampicillin 800 µg/ml shifted to 107 µg/ml (AM+AP) and ceftriaxone 58 µg/ml shifted to 2.6 µg/ml (CEF+AP) against MRSA. The synergistic activity of ampicillin and ceftriaxone plus apigenin combinations with FIC indices (CI) between 0.18-0.47. The modulation of methicillin-resistance by apigenin significantly enhanced the activities of ampicillin and ceftriaxone. The result of time-kill assays of the two drug combinations AM +AP and CEF+AP against MRSA showed significant inhibitory effect and reduced the colony count by approximately 99% after 8 h The results for outer membrane (OM) and inner membrane (IM) permeabilization showed that ampicillin and ceftriaxone in combination with apigenin damaged MRSA cytoplasmic membrane and caused subsequent leakage of intracellular constituents. Electron microscopy clearly showed that the above said combination also caused marked morphological damage of cell wall, cell shape and plasma membrane of this strain. From these results, it can be concluded that apigenin has the synergistic effect with ampicillin and ceftriaxone to reverse bacterial resistance against MRSA.
Comparison of body composition assessment methods in pediatric intestinal failure.
Mehta, Nilesh M; Raphael, Bram; Guteirrez, Ivan M; Quinn, Nicolle; Mitchell, Paul D; Litman, Heather J; Jaksic, Tom; Duggan, Christopher P
2014-07-01
The aim of the study was to examine the agreement of multifrequency bioelectric impedance analysis (BIA) and anthropometry with reference methods for body composition assessment in children with intestinal failure (IF). We conducted a prospective pilot study in children 14 years or younger with IF resulting from either short bowel syndrome or motility disorders. Bland-Altman analysis was used to examine the agreement between BIA and deuterium dilution in measuring total body water (TBW) and lean body mass (LBM), and between BIA and dual-energy x-ray absorptiometry (DXA) techniques in measuring LBM and fat mass (FM). FM and percent body fat (%BF) measurements by BIA and anthropometry were also compared in relation to those measured by deuterium dilution. Fifteen children with IF, median (interquartile range) age 7.2 (5.0, 10.0) years, and 10 (67%) boys, were studied. BIA and deuterium dilution were in good agreement with a mean bias (limits of agreement) of 0.9 (-3.2 to 5.0) for TBW (L) and 0.1 (-5.4 to 5.6) for LBM (kg) measurements. The mean bias (limits) for FM (kg) and %BF measurements were 0.4 (-3.8 to 4.6) kg and 1.7 (-16.9 to 20.3)%, respectively. The limits of agreement were within 1 standard deviation of the mean bias in 12 of 14 (86%) subjects for TBW and LBM, and in 11 of 14 (79%) for FM and %BF measurements. Mean bias (limits) for LBM (kg) and FM (kg) between BIA and DXA were 1.6 (-3.0 to 6.3) kg and -0.1 (-3.2 to 3.1) kg, respectively. Mean bias (limits) for FM (kg) and %BF between anthropometry and deuterium dilution were 0.2 (-4.2 to 4.6) and -0.2 (-19.5 to 19.1), respectively. The limits of agreement were within 1 standard deviation of the mean bias in 10 of 14 (71%) subjects. In children with IF, TBW and LBM measurements by multifrequency BIA method were in agreement with isotope dilution and DXA methods, with small mean bias and clinically acceptable limits of agreement. In comparison with deuterium dilution, BIA was comparable to anthropometry for FM and %BF assessments with small mean bias, but the limits of agreement were large. BIA is a reliable method for TBW and LBM assessments in population studies; however, its reliability in individual patients, especially for FM assessments, cannot be guaranteed.
Comparative study of SPORL and dilute-acid pretreatments of spruce for cellulosic ethanol production
L. Shuai; Q. Yang; Junyong Zhu; F.C. Lu; P.J. Weimer; J. Ralph; X.L. Pan
2010-01-01
The performance of two pretreatment methods, sulfite pretreatment to overcome recalcitrance of lignocelluloses (SPORL) and dilute acid (DA), was compared in pretreating softwood (spruce) for fuel ethanol production at 180C for 30 min with a sulfuric acid loading of 5% on oven-dry wood and a 5:1 liquor to-wood ratio. SPORL was supplemented with 9% sodium...
A novel 3D deformation measurement method under optical microscope for micro-scale bulge-test
NASA Astrophysics Data System (ADS)
Wu, Dan; Xie, Huimin
2017-11-01
A micro-scale 3D deformation measurement method combined with optical microscope is proposed in this paper. The method is based on gratings and phase shifting algorithm. By recording the grating images before and after deformation from two symmetrical angles and calculating the phases of the grating patterns, the 3D deformation field of the specimen can be extracted from the phases of the grating patterns. The proposed method was applied to the micro-scale bulge test. A micro-scale thermal/mechanical coupling bulge-test apparatus matched with the super-depth microscope was exploited. With the gratings fabricated onto the film, the deformed morphology of the bulged film was measured reliably. The experimental results show that the proposed method and the exploited bulge-test apparatus can be used to characterize the thermal/mechanical properties of the films at micro-scale successfully.
NASA Astrophysics Data System (ADS)
Nisa, K.; Nurhayati, S.; Apriyana, W.; Indrianingsih, A. W.
2017-12-01
Baeckea frutescens L. is a medicinal plant endemic to the tropical area and it has been used by locals for topical and oral ailments. This study investigated total phenolic and flavonoid contents and also evaluated in vitro antimicrobial and antioxidant activities of of Baeckea frutescens crude extracts. These extracts were assessed for their antibacterial activities against strains of Escherichia coli, Staphylococcus aureus, Salmonella thypii, and Pseudomonas aureginosa by the broth micro-dilution methods using a modified tetrazolium-based colorimetric assay (3-(4, 5-dimethylthiazol)-2, 5-diphenyl tetrazolium bromide (MTT) assay). Baeckea frutescens crude extracts were also tested against the stable DPPH (2,2-diphenyl-1-picryl-hydrazyl-hydrate) free-radical. The results indicated that Baeckea frutescens water and ethanol extracts possesed remarkable antibacterial activity with the minimum inhibitory concentration less than 100 μg/ml against Escherichia coli and Salmonella thypi. On the evaluation of the antioxidant activity via DPPH assay, Baeckea frutescens ethanol extracts exhibited a good antioxidant activity with IC50 less than 50 μg/ml and Baeckea frutescens water extracts showed a moderate antioxidant activity with IC50 less than 100 μg/ml.
Deep Coupled Integration of CSAC and GNSS for Robust PNT.
Ma, Lin; You, Zheng; Li, Bin; Zhou, Bin; Han, Runqi
2015-09-11
Global navigation satellite systems (GNSS) are the most widely used positioning, navigation, and timing (PNT) technology. However, a GNSS cannot provide effective PNT services in physical blocks, such as in a natural canyon, canyon city, underground, underwater, and indoors. With the development of micro-electromechanical system (MEMS) technology, the chip scale atomic clock (CSAC) gradually matures, and performance is constantly improved. A deep coupled integration of CSAC and GNSS is explored in this thesis to enhance PNT robustness. "Clock coasting" of CSAC provides time synchronized with GNSS and optimizes navigation equations. However, errors of clock coasting increase over time and can be corrected by GNSS time, which is stable but noisy. In this paper, weighted linear optimal estimation algorithm is used for CSAC-aided GNSS, while Kalman filter is used for GNSS-corrected CSAC. Simulations of the model are conducted, and field tests are carried out. Dilution of precision can be improved by integration. Integration is more accurate than traditional GNSS. When only three satellites are visible, the integration still works, whereas the traditional method fails. The deep coupled integration of CSAC and GNSS can improve the accuracy, reliability, and availability of PNT.
Deep Coupled Integration of CSAC and GNSS for Robust PNT
Ma, Lin; You, Zheng; Li, Bin; Zhou, Bin; Han, Runqi
2015-01-01
Global navigation satellite systems (GNSS) are the most widely used positioning, navigation, and timing (PNT) technology. However, a GNSS cannot provide effective PNT services in physical blocks, such as in a natural canyon, canyon city, underground, underwater, and indoors. With the development of micro-electromechanical system (MEMS) technology, the chip scale atomic clock (CSAC) gradually matures, and performance is constantly improved. A deep coupled integration of CSAC and GNSS is explored in this thesis to enhance PNT robustness. “Clock coasting” of CSAC provides time synchronized with GNSS and optimizes navigation equations. However, errors of clock coasting increase over time and can be corrected by GNSS time, which is stable but noisy. In this paper, weighted linear optimal estimation algorithm is used for CSAC-aided GNSS, while Kalman filter is used for GNSS-corrected CSAC. Simulations of the model are conducted, and field tests are carried out. Dilution of precision can be improved by integration. Integration is more accurate than traditional GNSS. When only three satellites are visible, the integration still works, whereas the traditional method fails. The deep coupled integration of CSAC and GNSS can improve the accuracy, reliability, and availability of PNT. PMID:26378542
Real-time monitoring of human blood clotting using a lateral excited film bulk acoustic resonator
NASA Astrophysics Data System (ADS)
Chen, Da; Wang, Jingjng; Wang, Peng; Guo, Qiuquan; Zhang, Zhen; Ma, Jilong
2017-04-01
Frequent assay of hemostatic status is an essential issue for the millions of patients using anticoagulant drugs. In this paper, we presented a micro-fabricated film bulk acoustic sensor for the real-time monitoring of blood clotting and the measurement of hemostatic parameters. The device was made of an Au/ZnO/Si3N4 film stack and excited by a lateral electric field. It operated under a shear mode resonance with the frequency of 1.42 GHz and had a quality factor of 342 in human blood. During the clotting process of blood, the resonant frequency decreased along with the change of blood viscosity and showed an apparent step-ladder curve, revealing the sequential clotting stages. An important hemostatic parameter, prothrombin time, was quantitatively determined from the frequency response for different dilutions of the blood samples. The effect of a typical anticoagulant drug (heparin) on the prothrombin time was exemplarily shown. The proposed sensor displayed a good consistency and clinical comparability with the standard coagulometric methods. Thanks to the availability of direct digital signals, excellent potentials of miniaturization and integration, the proposed sensor has promising application for point-of-care coagulation technologies.
Viral microRNA effects on persistent infection of human lymphoid cells by polyomavirus SV40
McNees, Adrienne L.; Harrigal, Lindsay J.; Kelly, Aoife; Minard, Charles G.; Wong, Connie
2018-01-01
Background Polyomaviruses, including simian virus 40 (SV40), display evidence of lymphotropic properties. This study analyzed the nature of SV40–human lymphocyte interactions in established cell lines and in primary lymphocytes. The effects of viral microRNA and the structure of the viral regulatory region on SV40 persistence were examined. Results SV40 DNA was maintained in infected B cell and myeloid cell lines during cell growth for at least 28 days. Limiting dilution analysis showed that low amounts of SV40 DNA (~2 copies per cell) were retained over time. Infected B cells remained viable and able to proliferate. Genome copies of the SV40 microRNA-null mutant persisted at higher levels than the DNA of wild-type viruses. Complex viral regulatory regions produced modestly higher DNA levels than simple regulatory regions. Viral large T-antigen protein was detected at low frequency and at low levels in infected B cells. Following infection of primary lymphocytes, SV40 DNA was detected in CD19+ B cells and CD14+ monocytes, but not in CD3+ T cells. Rescue attempts using either lysates of SV40-infected B lymphocytes, coculture of live cells, or infectious center assays all showed that replication-competent SV40 could be recovered on rare occasions. SV40 infections altered the expression of several B cell surface markers, with more pronounced changes following infections with the microRNA-null mutant. Conclusion These findings indicate that SV40 can establish persistent infections in human B lymphocytes. The cells retain low copy numbers of viral DNA; the infections are nonproductive and noncytolytic but can occasionally produce infectious virus. SV40 microRNA negatively regulates the degree of viral effects on B cells. Significance Lymphocytes may serve as viral reservoirs and may function to disseminate polyomaviruses to different tissues in a host. To our knowledge, this report is the first extensive analysis of viral microRNA effects on SV40 infection of human lymphocytes. PMID:29432481
2011-01-01
Background Hypertonic saline hydroxyethyl starch (HH) has been recommended for first line treatment of hemorrhagic shock. Its effects on coagulation are unclear. We studied in vitro effects of HH dilution on whole blood coagulation and platelet function. Furthermore 7.2% hypertonic saline, 6% hydroxyethylstarch (as ingredients of HH), and 0.9% saline solution (as control) were tested in comparable dilutions to estimate specific component effects of HH on coagulation. Methods The study was designed as experimental non-randomized comparative in vitro study. Following institutional review board approval and informed consent blood samples were taken from 10 healthy volunteers and diluted in vitro with either HH (HyperHaes®, Fresenius Kabi, Germany), hypertonic saline (HT, 7.2% NaCl), hydroxyethylstarch (HS, HAES6%, Fresenius Kabi, Germany) or NaCl 0.9% (ISO) in a proportion of 5%, 10%, 20% and 40%. Coagulation was studied in whole blood by rotation thrombelastometry (ROTEM) after thromboplastin activation without (ExTEM) and with inhibition of thrombocyte function by cytochalasin D (FibTEM), the latter was performed to determine fibrin polymerisation alone. Values are expressed as maximal clot firmness (MCF, [mm]) and clotting time (CT, [s]). Platelet aggregation was determined by impedance aggregrometry (Multiplate) after activation with thrombin receptor-activating peptide 6 (TRAP) and quantified by the area under the aggregation curve (AUC [aggregation units (AU)/min]). Scanning electron microscopy was performed to evaluate HyperHaes induced cell shape changes of thrombocytes. Statistics: 2-way ANOVA for repeated measurements, Bonferroni post hoc test, p < 0.01. Results Dilution impaired whole blood coagulation and thrombocyte aggregation in all dilutions in a dose dependent fashion. In contrast to dilution with ISO and HS, respectively, dilution with HH as well as HT almost abolished coagulation (MCFExTEM from 57.3 ± 4.9 mm (native) to 1.7 ± 2.2 mm (HH 40% dilution; p < 0.0001) and to 6.6 ± 3.4 mm (HT 40% dilution; p < 0.0001) and thrombocyte aggregation (AUC from 1067 ± 234 AU/mm (native) to 14.5 ± 12.5 AU/mm (HH 40% dilution; p < 0.0001) and to 20.4 ± 10.4 AU/min (HT 40% dilution; p < 0.0001) without differences between HH and HT (MCF: p = 0.452; AUC: p = 0.449). Conclusions HH impairs platelet function during in vitro dilution already at 5% dilution. Impairment of whole blood coagulation is significant after 10% dilution or more. This effect can be pinpointed to the platelet function impairing hypertonic saline component and to a lesser extend to fibrin polymerization inhibition by the colloid component or dilution effects. Accordingly, repeated administration and overdosage should be avoided. PMID:21310047
Hu, Y J; He, Y Y; Wang, Y R; Liu, C; Wang, M M; Gan, X; Wang, W; Yan, S F; Bai, Y; Peng, Z X; Li, F Q; Xu, J
2018-04-06
Objective: To obtain the serotype diversity and antimicrobial resistance of Salmonella isolates recovered from retail chicken carcasses for sale in six regions of China. Methods: From August 2010 to March 2012, each month 20 retail chicken carcasses including freshly slaughtered, chilled and frozen samples were collected from supermarkets and farmer's markets in 7 monitoring sites in Beijing, Jilin province, Inner Mongolia Autonomous, Shanxi province, Jiangsu province and Guangdong province, respectively. Samples were routinely collected for 12 months for each site. 1 680 chicken carcasses were collected in total and 2 629 Salmonella strains were isolated by PCR and biochemical method. Luminex xMAP method and classical slide agglutination method were carried out to determine isolates' serotypes. Minimal inhibitory concentrations (MICs) of 10 classes of antimicrobials including 14 agents were determined using broth micro-dilution method. Mocular methods were used to determine antimicrobial resistance genes of CIP-CTX-CT co-resistant isolates. Results: In all, 2 629 Salmonella isolates, there were 17 seorgroups and 58 serotypes, B and D1 were the dominant serogroups with rates of 34.7% ( n= 913) and 31.0% ( n= 815), Enteritidis (30.8%, n= 810), Indiana (17.6%, n= 463), Infantis (10.6%, n= 278) were the top three serovars. We found 224 CIP-CTX co-resistant S . Indiana containing 3 colistin resistant strains, one of them carrying mcr -1 gene and being ESBLs positive, which demonstrated a nine multi drug resistance against 11 antimicrobials tested. Conclusion: These data began to describe the complicated serovar diversity and heavy antimicrobial resistance of Salmonella isolates recovered from retail chicken carcasses in six regions of China. The findings highlight the emergence of ciprofloxacin and cefotaxime co-resistant S . Indiana and also a mcr -1 positive S . Indiana with heavy multi drug resistance.
Local Luminosity Function at 15 micro m and Galaxy Evolution Seen by ISOCAM 15 micro m Surveys
NASA Technical Reports Server (NTRS)
Xu, C.
2000-01-01
A local luminosity function at 15 micro m is derived using the bivariate (15 micro m vs. 60 micro m luminosities) method, based on the newly published ISOCAM LW3-band (15 micro m) survey of the very deep IRAS 60 micro m sample in the north ecliptic pole region (NEPR).
Nedea, S V; van Steenhoven, A A; Markvoort, A J; Spijker, P; Giordano, D
2014-05-01
The influence of gas-surface interactions of a dilute gas confined between two parallel walls on the heat flux predictions is investigated using a combined Monte Carlo (MC) and molecular dynamics (MD) approach. The accommodation coefficients are computed from the temperature of incident and reflected molecules in molecular dynamics and used as effective coefficients in Maxwell-like boundary conditions in Monte Carlo simulations. Hydrophobic and hydrophilic wall interactions are studied, and the effect of the gas-surface interaction potential on the heat flux and other characteristic parameters like density and temperature is shown. The heat flux dependence on the accommodation coefficient is shown for different fluid-wall mass ratios. We find that the accommodation coefficient is increasing considerably when the mass ratio is decreased. An effective map of the heat flux depending on the accommodation coefficient is given and we show that MC heat flux predictions using Maxwell boundary conditions based on the accommodation coefficient give good results when compared to pure molecular dynamics heat predictions. The accommodation coefficients computed for a dilute gas for different gas-wall interaction parameters and mass ratios are transferred to compute the heat flux predictions for a dense gas. Comparison of the heat fluxes derived using explicit MD, MC with Maxwell-like boundary conditions based on the accommodation coefficients, and pure Maxwell boundary conditions are discussed. A map of the heat flux dependence on the accommodation coefficients for a dense gas, and the effective accommodation coefficients for different gas-wall interactions are given. In the end, this approach is applied to study the gas-surface interactions of argon and xenon molecules on a platinum surface. The derived accommodation coefficients are compared with values of experimental results.
Ostrich specific semen diluent and sperm motility characteristics during in vitro storage.
Smith, A M J; Bonato, M; Dzama, K; Malecki, I A; Cloete, S W P
2018-06-01
The dilution of semen is a very important initial process for semen processing and evaluation, storage and preservation in vitro and efficient artificial insemination. The aim of the study was to evaluate the effect of two synthetic diluents (OS1 and OS2) on ostrich sperm motility parameters during in vitro storage. Formulation of OS1 was based on macro minerals (Na, K, P, Ca, Mg) and OS2 on the further addition of micro minerals (Se and Zn), based on mineral concentration determined in the ostrich seminal plasma (SP). Sperm motility was evaluated at different processing stages (neat, after dilution, during storage and after storage) by measuring several sperm motility variables using the Sperm Class Analyzer® (SCA). Processing (dilution, cooling and storage) of semen for in vitro storage purposes decreased the values for all sperm motility variables measured. The percentage motile (MOT) and progressive motile (PMOT) sperm decreased 20% to 30% during 24 h of storage, independent of diluent type. Quality of sperm swim (LIN, STR and WOB), however, was sustained during the longer storage periods (48 h) with the OS2 diluent modified with Se and Zn additions. Quality of sperm swim with use of OS1 was 6% to 8% less for the LIN, STR, and WOB variables. Male fitted as a fixed effect accounted for >60% of the variation for certain sperm motility variables (PMOT, MOT, VCL, VSL, VAP and ALH) evaluated at different processing stages. Semen from specific males had sustained sperm motility characteristics to a greater extent than that of other males during the 24-h storage period. Copyright © 2018 Elsevier B.V. All rights reserved.
Titos-Padilla, Silvia; Ruiz, José; Herrera, Juan Manuel; Brechin, Euan K; Wersndorfer, Wolfgang; Lloret, Francesc; Colacio, Enrique
2013-08-19
The synthesis, structure, magnetic, and luminescence properties of the Zn2Dy2 tetranuclear complex of formula {(μ3-CO3)2[Zn(μ-L)Dy(NO3)]2}·4CH3OH (1), where H2L is the compartmental ligand N,N',N″-trimethyl-N,N″-bis(2-hydroxy-3-methoxy-5-methylbenzyl)diethylenetriamine, are reported. The carbonate anions that bridge two Zn(μ-L)Dy units come from the atmospheric CO2 fixation in a basic medium. Fast quantum tunneling relaxation of the magnetization (QTM) is very effective in this compound, so that single-molecule magnet (SMM) behavior is only observed in the presence of an applied dc field of 1000 Oe, which is able to partly suppress the QTM relaxation process. At variance, a 1:10 Dy:Y magnetic diluted sample, namely, 1', exhibits SMM behavior at zero applied direct-current (dc) field with about 3 times higher thermal energy barrier than that in 1 (U(eff) = 68 K), thus demonstrating the important role of intermolecular dipolar interactions in favoring the fast QTM relaxation process. When a dc field of 1000 Oe is applied to 1', the QTM is almost fully suppressed, the reversal of the magnetization slightly slows, and U(eff) increases to 78 K. The dilution results combined with micro-SQUID magnetization measurements clearly indicate that the SMM behavior comes from single-ion relaxation of the Dy(3+) ions. Analysis of the relaxation data points out that a Raman relaxation process could significantly affect the Orbach relaxation process, reducing the thermal energy barrier U(eff) for slow relaxation of the magnetization.
Kang, Sung-Won; Lee, Woo-Jin; Choi, Soon-Chul; Lee, Sam-Sun; Heo, Min-Suk; Huh, Kyung-Hoe; Kim, Tae-Il; Yi, Won-Jin
2015-03-01
We have developed a new method of segmenting the areas of absorbable implants and bone using region-based segmentation of micro-computed tomography (micro-CT) images, which allowed us to quantify volumetric bone-implant contact (VBIC) and volumetric absorption (VA). The simple threshold technique generally used in micro-CT analysis cannot be used to segment the areas of absorbable implants and bone. Instead, a region-based segmentation method, a region-labeling method, and subsequent morphological operations were successively applied to micro-CT images. The three-dimensional VBIC and VA of the absorbable implant were then calculated over the entire volume of the implant. Two-dimensional (2D) bone-implant contact (BIC) and bone area (BA) were also measured based on the conventional histomorphometric method. VA and VBIC increased significantly with as the healing period increased (p<0.05). VBIC values were significantly correlated with VA values (p<0.05) and with 2D BIC values (p<0.05). It is possible to quantify VBIC and VA for absorbable implants using micro-CT analysis using a region-based segmentation method.
Applying a foil queue micro-electrode in micro-EDM to fabricate a 3D micro-structure
NASA Astrophysics Data System (ADS)
Xu, Bin; Guo, Kang; Wu, Xiao-yu; Lei, Jian-guo; Liang, Xiong; Guo, Deng-ji; Ma, Jiang; Cheng, Rong
2018-05-01
Applying a 3D micro-electrode in a micro electrical discharge machining (micro-EDM) can fabricate a 3D micro-structure with an up and down reciprocating method. However, this processing method has some shortcomings, such as a low success rate and a complex process for fabrication of 3D micro-electrodes. By focusing on these shortcomings, this paper proposed a novel 3D micro-EDM process based on the foil queue micro-electrode. Firstly, a 3D micro-electrode was discretized into several foil micro-electrodes and these foil micro-electrodes constituted a foil queue micro-electrode. Then, based on the planned process path, foil micro-electrodes were applied in micro-EDM sequentially and the micro-EDM results of each foil micro-electrode were able to superimpose the 3D micro-structure. However, the step effect will occur on the 3D micro-structure surface, which has an adverse effect on the 3D micro-structure. To tackle this problem, this paper proposes to reduce this adverse effect by rounded corner wear at the end of the foil micro-electrode and studies the impact of machining parameters on rounded corner wear and the step effect on the micro-structure surface. Finally, using a wire cutting voltage of 80 V, a current of 0.5 A and a pulse width modulation ratio of 1:4, the foil queue micro-electrode was fabricated by wire electrical discharge machining. Also, using a pulse width of 100 ns, a pulse interval of 200 ns, a voltage of 100 V and workpiece material of 304# stainless steel, the foil queue micro-electrode was applied in micro-EDM for processing of a 3D micro-structure with hemispherical features, which verified the feasibility of this process.
Wei, Lee Seong; Wee, Wendy
2013-06-01
This paper describes chemical composition and antimicrobial activity of Cymbopogon nardus citronella essential oil against Edwardsiella spp. (n = 21), Vibrio spp. (n = 6), Aeromonas spp. (n = 2), Escherichia coli (n = 2), Salmonella spp. (n = 2), Flavobacterium spp. (n = 1), Pseudomonas spp. (n = 1) and Streptococcus spp. (n = 1) isolated from internal organs of aquatic animals. Due to the ban of antibiotics for aquaculture use, this study was carried out to evaluate the potential of citronella essential oil as alternative to commercial antibiotic use against systemic bacteria in cultured aquatic animals. The essential oil of C. nardus was prepared by using the steam distillation method and the chemical composition of the essential oil was analyzed by gas chromatography-mass spectroscopy (GC-MS). Minimum inhibitory concentration (MIC) of the essential oil tested against bacterial isolates from various aquatic animals and ATCC type strains were determined using two-fold broth micro dilution method with kanamycin and eugenol as positive controls. A total of 22 chemical compounds were detected in C. nardus essential oil with 6-octenal, 3, 7-dimethyl- or citronellal representing the major compounds (29.6%). The MIC values of the citronella oil ranged from 0.244 µg/ml to 0.977 µg/ml when tested against the bacterial isolates. The results of the present study revealed the potential of C. nardus essential oil as alternative to commercial antibiotics for aquaculture use.
Arifullah, Mohmmed; Namsa, Nima Dandu; Mandal, Manabendra; Chiruvella, Kishore Kumar; Vikrama, Paritala; Gopal, Ghanta Rama
2013-01-01
Objective To evaluate the anti-bacterial and anti-oxidant activity of andrographolide (AND) and echiodinin (ECH) of Andrographis paniculata. Methods In this study, an attempt has been made to demonstrate the anti-microbial and anti-oxidant activity of isolated AND and ECH by broth micro-dilution method and 2,2-diphenyl-2-picryl-hydrazyl (DPPH) assay, respectively. Structure elucidation was determined by electro-spray ionization-MSD, NMR (1H and 13C) and IR spectra. Results AND was effective against most of the strains tested including Mycobacterium smegmatis, showing broad spectrum of growth inhibition activity with Minimum inhibitory concentration values against Staphylococcus aureus (100 µg/mL), Streptococcus thermophilus (350 µg/mL) Bacillus subtilis (100 µg/mL), Escherichia coli (50 µg/mL), Mycobacterium smegmatis (200 µg/mL), Klebsiella pneumonia (100 µg/mL), and Pseudomonas aeruginosa (200 µg/mL). ECH showed specific anti-bacterial activity against Staphylococcus aureus, Escherichia coli, Bacillus subtilis and Pseudomonas aeruginosa at a concentration higher than 225 µg/mL. Both AND and ECH were not effective against the two yeast strains, Candida albicans and Saccharomyces cerevisiae tested in this study. Conclusion This preliminary study showed promising anti-bacterial activity and moderate free radical scavenging activity of AND and ECH, and it may provide the scientific rationale for its popular folklore medicines. PMID:23905016
Experimental and theoretical studies of nanofluid thermal conductivity enhancement: a review
2011-01-01
Nanofluids, i.e., well-dispersed (metallic) nanoparticles at low- volume fractions in liquids, may enhance the mixture's thermal conductivity, knf, over the base-fluid values. Thus, they are potentially useful for advanced cooling of micro-systems. Focusing mainly on dilute suspensions of well-dispersed spherical nanoparticles in water or ethylene glycol, recent experimental observations, associated measurement techniques, and new theories as well as useful correlations have been reviewed. It is evident that key questions still linger concerning the best nanoparticle-and-liquid pairing and conditioning, reliable measurements of achievable knf values, and easy-to-use, physically sound computer models which fully describe the particle dynamics and heat transfer of nanofluids. At present, experimental data and measurement methods are lacking consistency. In fact, debates on whether the anomalous enhancement is real or not endure, as well as discussions on what are repeatable correlations between knf and temperature, nanoparticle size/shape, and aggregation state. Clearly, benchmark experiments are needed, using the same nanofluids subject to different measurement methods. Such outcomes would validate new, minimally intrusive techniques and verify the reproducibility of experimental results. Dynamic knf models, assuming non-interacting metallic nano-spheres, postulate an enhancement above the classical Maxwell theory and thereby provide potentially additional physical insight. Clearly, it will be necessary to consider not only one possible mechanism but combine several mechanisms and compare predictive results to new benchmark experimental data sets. PMID:21711739
Effect of essential oils prepared from Thai culinary herbs on sessile Candida albicans cultures.
Hovijitra, Ray S; Choonharuangdej, Suwan; Srithavaj, Theerathavaj
2016-01-01
Although medicinal herbs with fungicidal effects have been ubiquitously employed in traditional medicine, such effects of culinary herbs and spices still have to be elucidated. Therefore, it is noteworthy to determine the antifungal efficacy of some edible herbs used in Thai cuisine against sessile Candida albicans cultures, and to inquire if they can be further utilized as naturally-derived antifungals. Fourteen essential oils extracted from Thai culinary herbs and spices were tested for their antifungal activity against C. albicans using the agar disk diffusion method followed by broth micro-dilution method for the determination of minimum inhibitory concentration (MIC) and minimum fungicidal concentration. The oils with potent antifungal effects against planktonic fungi were then assessed for their effect against sessile fungus (adherent organisms and established biofilm culture). MIC of the oils against sessile C. albicans was evaluated by 2,3-bis-(2-methoxy-4-nitro-5-sulfophenyl)-2H-tetrazolium-5-carboxanilide reduction assay. All selected culinary herbs and spices, except galangal, garlic, and turmeric, exhibited inhibitory effects on planktonic yeast cells. Cinnamon bark and sweet basil leaf essential oils exhibited potent fungicidal effect on planktonic and sessile fungus. Sessile MICs were 8-16 times higher than planktonic MICs. Consequently, both cinnamon bark and sweet basil leaf herbal oils seem to be highly effective anti-Candida choices. (J Oral Sci 58, 365-371, 2016).
Kostić, Nađa; Dotsikas, Yannis; Jović, Nebojša; Stevanović, Galina; Malenović, Anđelija; Medenica, Mirjana
2015-05-10
In this paper, novel LC-MS/MS methods for the determination of antiepileptic drug pregabalin in dried matrix spots (DMS) are presented. This attractive technique of sample collection in micro amount was utilized in the form of dried blood spots (DBS) and dried plasma spots (DPS). Following a pre-column derivatization procedure, using n-propyl chloroformate in the presence of n-propanol, and consecutive liquid-liquid extraction, derivatized pregabalin and its internal standard, 4-aminocyclohexanecarboxylic acid, were detected in positive ion mode by applying two SRM transitions per analyte. A YMC-Pack Octyl column (50mm×4.0mm, 3μm particle size) maintained at 30°C, was utilized with running mobile phase composed of acetonitrile: 0.15% formic acid (85:15, v/v). Flow rate was 550μL/min and total run time 2min. Established methods were fully validated over the concentration range of 0.200-20.0μg/mL for DBS and 0.400-40.0μg/mL for DPS, respectively, while specificity, accuracy, precision, recovery, matrix-effect, stability, dilution integrity and spot homogeneity were found within acceptance criteria. Validated methods were applied for the determination of pregabalin levels in dried blood and plasma samples obtained from patients with epilepsy, after per os administration of commercial capsules. Comparison of drug level in blood and plasma, as well as correction steps undertaken in order to overcome hematocrit issue, when analyzing DBS, are also given. Copyright © 2015 Elsevier B.V. All rights reserved.
Kang, Sung-Won; Lee, Woo-Jin; Choi, Soon-Chul; Lee, Sam-Sun; Heo, Min-Suk; Huh, Kyung-Hoe
2015-01-01
Purpose We have developed a new method of segmenting the areas of absorbable implants and bone using region-based segmentation of micro-computed tomography (micro-CT) images, which allowed us to quantify volumetric bone-implant contact (VBIC) and volumetric absorption (VA). Materials and Methods The simple threshold technique generally used in micro-CT analysis cannot be used to segment the areas of absorbable implants and bone. Instead, a region-based segmentation method, a region-labeling method, and subsequent morphological operations were successively applied to micro-CT images. The three-dimensional VBIC and VA of the absorbable implant were then calculated over the entire volume of the implant. Two-dimensional (2D) bone-implant contact (BIC) and bone area (BA) were also measured based on the conventional histomorphometric method. Results VA and VBIC increased significantly with as the healing period increased (p<0.05). VBIC values were significantly correlated with VA values (p<0.05) and with 2D BIC values (p<0.05). Conclusion It is possible to quantify VBIC and VA for absorbable implants using micro-CT analysis using a region-based segmentation method. PMID:25793178
Design method of LED rear fog lamp based on freeform micro-surface reflectors
NASA Astrophysics Data System (ADS)
Yu, Jindong; Wu, Heng
2017-11-01
We propose a practical method for the design of a light-emitting diode (LED) rear fog lamp based on freeform micro-surface reflectors. The lamp consists of nine LEDs and each of them has a freeform micro-surface reflector correspondingly. The micro-surface reflector design includes three steps. An initial freeform reflector is first built based on the light energy maps. The micro-surface reflector is then constructed on the bias of the initial one. Finally, a two-step method is designed to optimize the micro-surface reflector. With the proposed method, a module is designed and LCW DURIS E5 LED source whose emitting surface is 5.7 mm × 3.0 mm is adopted for simulation. A prototype is also assembled and fabricated to verify the real performance. Both the simulation and experimental results demonstrate that the luminous intensity distribution can well fulfill the requirements of ECE No.38 regulation. Furthermore, more than 79% energy can be saved when compared with the rear fog lamps using conventional sources.
Jiang, Liqun; Wu, Nannan; Zheng, Anqing; Zhao, Zengli; He, Fang; Li, Haibin
2016-01-01
Fermentable sugars are important intermediates in the biological conversion of biomass. Hemicellulose and amorphous cellulose are easily hydrolyzed to fermentable sugars in dilute acid, whereas crystalline cellulose is more difficult to be hydrolyzed. Cellulose fast pyrolysis is an alternative method to liberate valuable fermentable sugars from biomass. The amount of levoglucosan generated from lignocellulose by fast pyrolysis is usually lower than the theoretical yield based on the cellulose fraction. Pretreatment is a promising route to improve the yield of levoglucosan from lignocellulose. The integration of dilute sulfuric acid hydrolysis and fast pyrolysis to obtain fermentable sugars was evaluated in this study. Dilute sulfuric acid hydrolysis could remove more than 95.1 and 93.4 % of xylan (the main component of hemicellulose) from sugarcane bagasse and corncob with high yield of xylose. On the other hand, dilute sulfuric acid hydrolysis was also an effective pretreatment to enhance levoglucosan yield from lignocellulose. Dilute acid hydrolysis could accumulate glucan (the component of cellulose) and remove most of the alkali and alkaline earth metals which were powerful catalysts during fast pyrolysis. Further increase in dilute acid concentration (from 0 to 2 %) in pretreatment could promote the yield of levoglucosan in fast pyrolysis. The acid pretreated sugarcane bagasse and corncob gave levoglucosan yields of 43.8 and 35.2 % which were obvious higher than those of raw sugarcane bagasse (12.0 %) and corncob (7.0 %). Obtaining fermentable sugars by combination dilute acid hydrolysis of xylan and fast pyrolysis of glucan could make full utilization of biomass, and get fermentable sugars economically from biomass for bio-refinery.
Micro optical fiber light source and sensor and method of fabrication thereof
Kopelman, Raoul; Tan, Weihong; Shi, Zhong-You
1997-01-01
This invention relates generally to the development of and a method of fabricating a fiber optic micro-light source and sensor (50). An optical fiber micro-light source (50) is presented whose aperture is extremely small yet able to act as an intense light source. Light sources of this type have wide ranging applications, including use as micro-sensors (22) in NSOM. Micro-sensor light sources have excellent detection limits as well as photo stability, reversibility, and millisecond response times. Furthermore, a method for manufacturing a micro optical fiber light source is provided. It involves the photo-chemical attachment of an optically active material onto the end surface of an optical fiber cable which has been pulled to form an end with an extremely narrow aperture. More specifically, photopolymerization has been applied as a means to photo-chemically attach an optically active material (60). This process allows significant control of the size of the micro light source (50). Furthermore, photo-chemically attaching an optically active material (60) enables the implementation of the micro-light source in a variety of sensor applications.
Micro optical fiber light source and sensor and method of fabrication thereof
Kopelman, Raoul; Tan, Weihong; Shi, Zhong-You
1994-01-01
This invention relates generally to the development of and a method of fabricating a micro optical fiber light source. An optical fiber micro-light source is presented whose aperture is extremely small yet able to act as an intense light source. Light sources of this type have wide ranging applications, including use as micro-sensors in NSOM. Micro-sensor light sources have excellent detection limits as well as photo stability, reversibility, and millisecond response times. Furthermore, a method for manufacturing a micro optical fiber light source is provided. It involves the photo-chemical attachment of an optically active material onto the end surface of an optical fiber cable which has been pulled to form an end with an extremely narrow aperture. More specifically, photopolymerization has been applied as a means to photo-chemically attach an optically active material. This process allows significant control of the size of the micro light source. Furthermore, photo-chemically attaching an optically active material enables the implementation of the micro-light source in a variety of sensor applications.
Micro optical fiber light source and sensor and method of fabrication thereof
Kopelman, R.; Tan, W.; Shi, Z.Y.
1997-05-06
This invention relates generally to the development of and a method of fabricating a fiber optic micro-light source and sensor. An optical fiber micro-light source is presented whose aperture is extremely small yet able to act as an intense light source. Light sources of this type have wide ranging applications, including use as micro-sensors in NSOM. Micro-sensor light sources have excellent detection limits as well as photo stability, reversibility, and millisecond response times. Furthermore, a method for manufacturing a micro optical fiber light source is provided. It involves the photo-chemical attachment of an optically active material onto the end surface of an optical fiber cable which has been pulled to form an end with an extremely narrow aperture. More specifically, photopolymerization has been applied as a means to photo-chemically attach an optically active material. This process allows significant control of the size of the micro light source. Furthermore, photo-chemically attaching an optically active material enables the implementation of the micro-light source in a variety of sensor applications. 10 figs.
Micro optical fiber light source and sensor and method of fabrication thereof
Kopelman, R.; Tan, W.; Shi, Z.Y.
1994-11-01
This invention relates generally to the development of and a method of fabricating a micro optical fiber light source. An optical fiber micro-light source is presented whose aperture is extremely small yet able to act as an intense light source. Light sources of this type have wide ranging applications, including use as micro-sensors in NSOM. Micro-sensor light sources have excellent detection limits as well as photo stability, reversibility, and millisecond response times. Furthermore, a method for manufacturing a micro optical fiber light source is provided. It involves the photo-chemical attachment of an optically active material onto the end surface of an optical fiber cable which has been pulled to form an end with an extremely narrow aperture. More specifically, photopolymerization has been applied as a means to photo-chemically attach an optically active material. This process allows significant control of the size of the micro light source. Furthermore, photo-chemically attaching an optically active material enables the implementation of the micro-light source in a variety of sensor applications. 4 figs.
Optical assembly of bio-hybrid micro-robots.
Barroso, Álvaro; Landwerth, Shirin; Woerdemann, Mike; Alpmann, Christina; Buscher, Tim; Becker, Maike; Studer, Armido; Denz, Cornelia
2015-04-01
The combination of micro synthetic structures with bacterial flagella motors represents an actual trend for the construction of self-propelled micro-robots. The development of methods for fabrication of these bacteria-based robots is a first crucial step towards the realization of functional miniature and autonomous moving robots. We present a novel scheme based on optical trapping to fabricate living micro-robots. By using holographic optical tweezers that allow three-dimensional manipulation in real time, we are able to arrange the building blocks that constitute the micro-robot in a defined way. We demonstrate exemplarily that our method enables the controlled assembly of living micro-robots consisting of a rod-shaped prokaryotic bacterium and a single elongated zeolite L crystal, which are used as model of the biological and abiotic components, respectively. We present different proof-of-principle approaches for the site-selective attachment of the bacteria on the particle surface. The propulsion of the optically assembled micro-robot demonstrates the potential of the proposed method as a powerful strategy for the fabrication of bio-hybrid micro-robots.
Bougnoux, M.-E.; Accoceberry, I.; Angoulvant, A.; Bailly, E.; Botterel, F.; Chevrier, S.; Chouaki, T.; Dalle, F.; Datry, A.; Dupuis, A.; Fekkar, A.; Gangneux, J. P.; Guitard, J.; Hennequin, C.; Le Govic, Y.; Le Pape, P.; Maubon, D.; Sautour, M.; Sendid, B.; Chandenier, J.
2016-01-01
In vitro susceptibility of 933 Candida isolates, from 16 French hospitals, to micafungin was determined using the Etest in each center. All isolates were then sent to a single center for determination of MICs by the EUCAST reference method. Overall essential agreement between the two tests was 98.5% at ±2 log2 dilutions and 90.2% at ±1 log2 dilutions. Categorical agreement was 98.2%. The Etest is a valuable alternative to EUCAST for the routine determination of micafungin MICs in medical mycology laboratories. PMID:27297480
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rogers, S.E.
1988-10-01
This workshop was held in Research Triangle Park, NC in October of 1986. The objectives of the workshop were to review the current methods of determining atmospheric dilution for use in hazard identification, emergency-preparedness planning, and emergency response; to provide recommendations for choosing among these methods; and, finally, to define the role of the meteorologist in hazard identification, emergency planning, etc. Several invited papers were presented, and panel discussions were held to meet the objectives. The results are presented and discussed.
NASA Astrophysics Data System (ADS)
Wyss, Simon A.; Guillevic, Myriam; Vicar, Martin; Nieuwenkamp, Gerard; Vollmer, Martin K.; Pascale, Céline; Reimann, Stefan; Niederhauser, Bernhard; Emmenegger, Lukas
2017-04-01
We developed two SI-traceable methods, using both static and dynamic preparation steps, to produce reference gas mixtures for sulfur hexafluoride (SF6) in gas cylinders at pmol/mol level. This research activity is conducted under the framework of the European EMRP HIGHGAS project, in support of the high quality measurements of this important greenhouse gas in the earth's atmosphere. In the method used by the Czech Metrology Institute (CMI) a parent mixture of SF6 in synthetic air was produced in an aluminium cylinder at VSL as a first step. This mixture was produced gravimetrically according to ISO 6142 at an amount fraction of 1 μmol/mol. In the second step this primary standard was further diluted to near-ambient amount fraction, with the use of a three-step dilution system and directly pressurised into aluminium cylinders to a pressure of 10 bars. The second method used by the Federal Institute of Metrology (METAS) has already been applied to other fluorinated gases such as HFC-125 and HFC-1234yf. In this method a highly concentrated mixture is produced by spiking a purified synthetic air (matrix gas) with SF6 from a permeation device. The mass loss of SF6 in the permeation device is observed by a magnetic suspension balance. In a second step this mixture is diluted with matrix gas to the desired concentrations. All flows are controlled with mass flow controllers. The diluted gas was transferred into Silconert2000-coated stainless steel cylinders by cryo-filling. The final gas mixtures at near-ambient amount fraction were measured on a Medusa gas chromatography-mass spectrometry system (Medusa-GC/MS) against working standards calibrated on existing scales of the Scripps Institution of Oceanography (SIO) and compared to other scales [1]. The agreement of the assigned values by the CMI and METAS, with the measured values referenced on the SIO scale was excellent. This results show that with this methods we are able to produce accurate SI-traceable gas mixtures at near-ambient amount fraction for SF6, without extensive static dilutions. [1] Benjamin R. Miller, Ray F. Weiss, Peter K. Salameh, Toste Tanhua, Brian R. Greally, Jens Mühle, Peter G. Simmonds, Anal. Chem., 2008, 80, 1536.
Evaluation of normalization methods in mammalian microRNA-Seq data
Garmire, Lana Xia; Subramaniam, Shankar
2012-01-01
Simple total tag count normalization is inadequate for microRNA sequencing data generated from the next generation sequencing technology. However, so far systematic evaluation of normalization methods on microRNA sequencing data is lacking. We comprehensively evaluate seven commonly used normalization methods including global normalization, Lowess normalization, Trimmed Mean Method (TMM), quantile normalization, scaling normalization, variance stabilization, and invariant method. We assess these methods on two individual experimental data sets with the empirical statistical metrics of mean square error (MSE) and Kolmogorov-Smirnov (K-S) statistic. Additionally, we evaluate the methods with results from quantitative PCR validation. Our results consistently show that Lowess normalization and quantile normalization perform the best, whereas TMM, a method applied to the RNA-Sequencing normalization, performs the worst. The poor performance of TMM normalization is further evidenced by abnormal results from the test of differential expression (DE) of microRNA-Seq data. Comparing with the models used for DE, the choice of normalization method is the primary factor that affects the results of DE. In summary, Lowess normalization and quantile normalization are recommended for normalizing microRNA-Seq data, whereas the TMM method should be used with caution. PMID:22532701
Probing the micro-rheological properties of aerosol particles using optical tweezers
NASA Astrophysics Data System (ADS)
Power, Rory M.; Reid, Jonathan P.
2014-07-01
The use of optical trapping techniques to manipulate probe particles for performing micro-rheological measurements on a surrounding fluid is well-established. Here, we review recent advances made in the use of optical trapping to probe the rheological properties of trapped particles themselves. In particular, we review observations of the continuous transition from liquid to solid-like viscosity of sub-picolitre supersaturated solution aerosol droplets using optical trapping techniques. Direct measurements of the viscosity of the particle bulk are derived from the damped oscillations in shape following coalescence of two particles, a consequence of the interplay between viscous and surface forces and the capillary driven relaxation of the approximately spheroidal composite particle. Holographic optical tweezers provide a facile method for the manipulation of arrays of particles allowing coalescence to be controllably induced between two micron-sized aerosol particles. The optical forces, while sufficiently strong to confine the composite particle, are several orders of magnitude weaker than the capillary forces driving relaxation. Light, elastically back-scattered by the particle, is recorded with sub-100 ns resolution allowing measurements of fast relaxation (low viscosity) dynamics, while the brightfield image can be used to monitor the shape relaxation extending to times in excess of 1000 s. For the slowest relaxation dynamics studied (particles with the highest viscosity) the presence and line shape of whispering gallery modes in the cavity enhanced Raman spectrum can be used to infer the relaxation time while serving the dual purpose of allowing the droplet size and refractive index to be measured with accuracies of ±0.025% and ±0.1%, respectively. The time constant for the damped relaxation can be used to infer the bulk viscosity, spanning from the dilute solution limit to a value approaching that of a glass, typically considered to be >1012 Pa s, whilst the frequencies of the normal modes of the oscillations of the particle can be used to infer surface properties. We will review the use of optical tweezers for studying the viscosity of aerosol particles and discuss the potential use of this micro-rheological tool for probing the fundamental concepts of phase, thermodynamic equilibrium and metastability.
Lee, Seungwoo; Kang, Hong Suk; Park, Jung-Ki
2012-04-24
This review demonstrates directional photofluidization lithography (DPL), which makes it possible to fabricate a generic and sophisticated micro/nanoarchitecture that would be difficult or impossible to attain with other methods. In particular, DPL differs from many of the existing micro/nanofabrication methods in that the post-treatment (i.e., photofluidization), after the preliminary fabrication process of the original micro/nanostructures, plays a pivotal role in the various micro/nanostructural evolutions including the deterministic reshaping of architectures, the reduction of structural roughness, and the dramatic enhancement of pattern resolution. Also, DPL techniques are directly compatible with a parallel and scalable micro/nanofabrication. Thus, DPL with such extraordinary advantages in micro/nanofabrication could provide compelling opportunities for basic micro/nanoscale science as well as for general technology applications. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Biggar, Kyle K; Wu, Cheng-Wei; Storey, Kenneth B
2014-10-01
This study makes a significant advancement on a microRNA amplification technique previously used for expression analysis and sequencing in animal models without annotated mature microRNA sequences. As research progresses into the post-genomic era of microRNA prediction and analysis, the need for a rapid and cost-effective method for microRNA amplification is critical to facilitate wide-scale analysis of microRNA expression. To facilitate this requirement, we have reoptimized the design of amplification primers and introduced a polyadenylation step to allow amplification of all mature microRNAs from a single RNA sample. Importantly, this method retains the ability to sequence reverse transcription polymerase chain reaction (RT-PCR) products, validating microRNA-specific amplification. Copyright © 2014 Elsevier Inc. All rights reserved.
Shawar, R; Paetznick, V; Witte, Z; Ensign, L G; Anaissie, E; LaRocco, M
1992-01-01
A study was performed in two laboratories to evaluate the effect of growth medium and test methodology on inter- and intralaboratory variations in the MICs of amphotericin B (AMB), flucytosine (5FC), fluconazole (FLU), itraconazole (ITRA), and the triazole Sch 39304 (SCH) against 14 isolates of Candida albicans. Testing was performed by broth microdilution and semisolid agar dilution with the following media, buffered to pH 7.0 with morpholinepropanesulfonic acid (MOPS): buffered yeast nitrogen base (BYNB), Eagle's minimal essential medium (EMEM), RPMI 1640 medium (RPMI), and synthetic amino acid medium for fungi (SAAMF). Inocula were standardized spectrophotometrically, and endpoints were defined by the complete absence of growth for AMB and by no more than 25% of the growth in the drug-free control for all other agents. Comparative analyses of median MICs, as determined by each test method, were made for all drug-medium combinations. Both methods yielded similar (+/- 1 twofold dilution) median MICs for AMB in EMEM and RPMI, 5FC in all media, and FLU in EMEM, RPMI, and SAAMF. In contrast, substantial between-method variations in median MICs were seen for AMB in BYNB and SAAMF, FLU In BYNB, and ITRA and SCH in all media. Interlaboratory concordance of median MICs was good for AMB, 5FC, and FLU but poor for ITRA and SCH in all media. Endpoint determinations were analyzed by use of kappa statistical analyses for evaluating the strength of observer agreement. Moderate to almost perfect interlaboratory agreement occurred with AMB and 5FC in all media and with FLU in EMEM, RPMI, and SAAMF, irrespective of the test method. Slight to almost perfect interlaboratory agreement occurred with ITRA and SCH in EMEM, RPMI, and SAAMF when tested by semisolid agar dilution but not broth microdilution. Kappa values assessing intralaboratory agreement between methods were high for 5FC in all media, for AMB in BYNB, ENEM, and RPMI, and for FLU in EMEM, RPMI, and SAAMF. One laboratory, but not the other, reported substantial to almost perfect agreement between methods for ITRA, and SCH in EMEM, RPMI, and SAAMF. Both laboratories reported poor agreement between methods for the azoles in BYNB. Discrepancies noted in azole-BYNB combinations were largely due to the greater inhibitory effect of these agents in BYNB than in other media. These results indicate that the semisolid agar dilution and broth microdilution methods with EMEM or RPMI yield equivalent and reproducible MICs for AMB, 5FC, and FLU but not ITRA and SCH. PMID:1500502
Shawar, R; Paetznick, V; Witte, Z; Ensign, L G; Anaissie, E; LaRocco, M
1992-08-01
A study was performed in two laboratories to evaluate the effect of growth medium and test methodology on inter- and intralaboratory variations in the MICs of amphotericin B (AMB), flucytosine (5FC), fluconazole (FLU), itraconazole (ITRA), and the triazole Sch 39304 (SCH) against 14 isolates of Candida albicans. Testing was performed by broth microdilution and semisolid agar dilution with the following media, buffered to pH 7.0 with morpholinepropanesulfonic acid (MOPS): buffered yeast nitrogen base (BYNB), Eagle's minimal essential medium (EMEM), RPMI 1640 medium (RPMI), and synthetic amino acid medium for fungi (SAAMF). Inocula were standardized spectrophotometrically, and endpoints were defined by the complete absence of growth for AMB and by no more than 25% of the growth in the drug-free control for all other agents. Comparative analyses of median MICs, as determined by each test method, were made for all drug-medium combinations. Both methods yielded similar (+/- 1 twofold dilution) median MICs for AMB in EMEM and RPMI, 5FC in all media, and FLU in EMEM, RPMI, and SAAMF. In contrast, substantial between-method variations in median MICs were seen for AMB in BYNB and SAAMF, FLU In BYNB, and ITRA and SCH in all media. Interlaboratory concordance of median MICs was good for AMB, 5FC, and FLU but poor for ITRA and SCH in all media. Endpoint determinations were analyzed by use of kappa statistical analyses for evaluating the strength of observer agreement. Moderate to almost perfect interlaboratory agreement occurred with AMB and 5FC in all media and with FLU in EMEM, RPMI, and SAAMF, irrespective of the test method. Slight to almost perfect interlaboratory agreement occurred with ITRA and SCH in EMEM, RPMI, and SAAMF when tested by semisolid agar dilution but not broth microdilution. Kappa values assessing intralaboratory agreement between methods were high for 5FC in all media, for AMB in BYNB, ENEM, and RPMI, and for FLU in EMEM, RPMI, and SAAMF. One laboratory, but not the other, reported substantial to almost perfect agreement between methods for ITRA, and SCH in EMEM, RPMI, and SAAMF. Both laboratories reported poor agreement between methods for the azoles in BYNB. Discrepancies noted in azole-BYNB combinations were largely due to the greater inhibitory effect of these agents in BYNB than in other media. These results indicate that the semisolid agar dilution and broth microdilution methods with EMEM or RPMI yield equivalent and reproducible MICs for AMB, 5FC, and FLU but not ITRA and SCH.
Deeb, G M; Borovetz, H S; Griffith, B P; Hardesty, R L
1980-01-01
The dilution technique for determining cardiac output using indocyanine green dye is limited in patients weighing less than 20 kg because of the obligatory volume loss. Reproducible achieved using the green dye dilution method by the establishment of a low flow peripheral arteriovenous shunt. The shunt materials were treated with thromboresistant agents--TDMAC (7%) and albumin (1 g/dl)--to facilitate the use of this technique without heparin. For A-V shunt flow rates of 8-30 cc/min reproducible values of cardiac output were obtained for up to 38 hours which were in good agreement with determinations made using the conventional technique of dye dilution. PMID:6986120
Karch, Jakub; Bartl, Benjamin; Dudak, Jan; Zemlicka, Jan; Krejci, Frantisek
2016-12-01
Historical beeswax seals are unique cultural heritage objects. Unfortunately, a number of historical sealing waxes show a porous structure with a strong tendency to stratification and embrittlement, which makes these objects extremely prone to mechanical damage. The understanding of beeswax degradation processes therefore plays an important role in the preservation and consequent treatment of these objects. Conventional methods applied for the investigation of beeswax materials (e.g. gas chromatography) are of a destructive nature or bring only limited information about the sample surface (microscopic techniques). Considering practical limitations of conventional methods and ethical difficulties connected with the sampling of the historical material, radiation imaging methods such as X-ray micro-tomography presents a promising non-destructive tool for the onward scientific research in this field. In this contribution, we present the application of high-contrast X-ray micro-radiography and micro-tomography for the investigation of beeswax seal fragments. The method is based on the application of the large area photon-counting detector recently developed at our institute. The detector combines the advantages of single-photon counting technology with a large field of view. The method, consequently, enables imaging of relatively large objects with high geometrical magnification. In the reconstructed micro-tomographies of investigated historical beeswax seals, we are able to reveal morphological structures such as stratification, micro-cavities and micro-fractures with spatial resolution down to 5μm non-destructively and with high imaging quality. The presented work therefore demonstrates that a combination of state-of-the-art hybrid pixel semiconductor detectors and currently available micro-focus x-ray sources makes it possible to apply X-ray micro-radiography and micro-tomography as a valuable non-destructive tool for volumetric beeswax seal morphological studies. Copyright © 2016 Elsevier Ltd. All rights reserved.
Diluted thrombin time reliably measures low to intermediate plasma dabigatran concentrations.
Božič-Mijovski, Mojca; Malmström, Rickard E; Malovrh, Petra; Antovic, Jovan P; Vene, Nina; Šinigoj, Petra; Mavri, Alenka
2016-07-01
Direct oral anticoagulant dabigatran was first introduced as a fixed-dose drug without routine coagulation monitoring, but current recommendations suggest that diluted thrombin time can be used to estimate plasma drug level. The aim of this study was to assess a diluted thrombin time assay based on the same thrombin reagent already used for traditional thrombin time measurements that reliably measure low to intermediate plasma dabigatran levels. We included 44 patients with atrial fibrillation who started treatment with dabigatran 150 mg (23 patients) or 110 mg (21 patients) twice a day. Blood samples were collected at baseline (no dabigatran) and 2-4 weeks after the beginning of dabigatran therapy at trough and at peak. Plasma dabigatran levels were measured with diluted thrombin time and compared to liquid chromatography with tandem mass spectrometry as the reference method. The performance of the diluted thrombin time was compared to Hemoclot® Thrombin Inhibitor and Ecarin Chromogenic Assay. In ex vivo plasma samples, diluted thrombin time highly correlated with the liquid chromatography with tandem mass spectrometry (Pearson's R = 0.9799). In the low to intermediate range (dabigatran concentration ≤ 100 µg/L) diluted thrombin time correlated significantly more closely to the liquid chromatography with tandem mass spectrometry (R = 0.964) than Hemoclot® Thrombin Inhibitor (R = 0.935, p = 0.05) or Ecarin Chromogenic Assay (R = 0.915, p < 0.01). It was also the only functional assay without any significant bias in the low to intermediate range. Both trough and peak diluted thrombin time values were similar to liquid chromatography with tandem mass spectrometry. We conclude that the diluted thrombin time assay presented in this study reliably detects dabigatran and that it is superior to the Hemoclot® Thrombin Inhibitor assay in the low to intermediate range. © The Author(s) 2015.
Pecly, José Otavio Goulart
2018-01-01
The alternative use of effluent turbidity to determine the dilution field of a domestic marine outfall located off the city of Rio de Janeiro was evaluated through field work comprising fluorescent dye tracer injection and tracking with simultaneous monitoring of sea water turbidity. A preliminary laboratory assessment was carried out with a sample of the outfall effluent whose turbidity was measured by the nephelometric method before and during a serial dilution process. During the field campaign, the dye tracer was monitored with field fluorometers and the turbidity was observed with an optical backscattering sensor interfaced to an OEM data acquisition system. About 4,000 samples were gathered, covering an area of 3 km × 3 km near the outfall diffusers. At the far field - where a drift towards the coastline was observed - the effluent plume was adequately labeled by the dye tracer. The turbidity plume was biased due to the high and variable background turbidity of sea water. After processing the turbidity dataset with a baseline detrending method, the plume presented high correlation with the dye tracer plume drawn on the near dilution field. However, dye tracer remains more robust than effluent turbidity.
Godshaw, Joshua; Hopfer, Helene; Nelson, Jenny; Ebeler, Susan E
2017-09-25
Wine elemental composition varies by cultivar, geographic origin, viticultural and enological practices, and is often used for authenticity validation. Elemental analysis of wine by Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is challenging due to the potential for non-spectral interferences and plasma instability arising from organic matrix components. Sample preparation mitigates these interferences, however, conflicting recommendations of best practices in ICP-MS analysis of wine have been reported. This study compared direct dilution, microwave-assisted acid digestion, and two filtration sample pretreatments, acidification prior to filtration and filtration followed by acidification, in elemental profiling of one white and three red table wines by ICP-MS. Of 43 monitored isotopes, 37 varied by sample preparation method, with significantly higher results of 17 isotopes in the microwave-digested samples. Both filtration treatments resulted in lower results for 11 isotopes compared to the other methods. Finally, isotope dilution determination of copper based on natural abundances and the 63 Cu: 65 Cu instrument response ratio agreed with external calibration and confirmed a significant sample preparation effect. Overall, microwave digestion did not compare favorably, and direct dilution was found to provide the best compromise between ease of use and result accuracy and precision, although all preparation strategies were able to differentiate the wines.
Ekins, Sean; Olechno, Joe; Williams, Antony J.
2013-01-01
Dispensing and dilution processes may profoundly influence estimates of biological activity of compounds. Published data show Ephrin type-B receptor 4 IC50 values obtained via tip-based serial dilution and dispensing versus acoustic dispensing with direct dilution differ by orders of magnitude with no correlation or ranking of datasets. We generated computational 3D pharmacophores based on data derived by both acoustic and tip-based transfer. The computed pharmacophores differ significantly depending upon dispensing and dilution methods. The acoustic dispensing-derived pharmacophore correctly identified active compounds in a subsequent test set where the tip-based method failed. Data from acoustic dispensing generates a pharmacophore containing two hydrophobic features, one hydrogen bond donor and one hydrogen bond acceptor. This is consistent with X-ray crystallography studies of ligand-protein interactions and automatically generated pharmacophores derived from this structural data. In contrast, the tip-based data suggest a pharmacophore with two hydrogen bond acceptors, one hydrogen bond donor and no hydrophobic features. This pharmacophore is inconsistent with the X-ray crystallographic studies and automatically generated pharmacophores. In short, traditional dispensing processes are another important source of error in high-throughput screening that impacts computational and statistical analyses. These findings have far-reaching implications in biological research. PMID:23658723
NASA Astrophysics Data System (ADS)
Cho, Byoung-Kwan; Kim, Moon S.; Chen, Yud-Ren
2005-11-01
Emerging concerns about safety and security in current mass production of food products necessitate rapid and reliable inspection for contaminant-free products. Diluted fecal residues on poultry processing plant equipment surface, not easily discernable from water by human eye, are contamination sources for poultry carcasses. Development of sensitive detection methods for fecal residues is essential to ensure safe production of poultry carcasses. Hyperspectral imaging techniques have shown good potential for detecting of the presence of fecal and other biological substances on food and processing equipment surfaces. In this study, use of high spatial resolution hyperspectral reflectance and fluorescence imaging (with UV-A excitation) is presented as a tool for selecting a few multispectral bands to detect diluted fecal and ingesta residues on materials used for manufacturing processing equipment. Reflectance and fluorescence imaging methods were compared for potential detection of a range of diluted fecal residues on the surfaces of processing plant equipment. Results showed that low concentrations of poultry feces and ingesta, diluted up to 1:100 by weight with double distilled water, could be detected using hyperspectral fluorescence images with an accuracy of 97.2%. Spectral bands determined in this study could be used for developing a real-time multispectral inspection device for detection of harmful organic residues on processing plant equipment.
Hyperpolarization of “Neat” Liquids by NMR Signal Amplification by Reversible Exchange
2016-01-01
We report NMR Signal Amplification by Reversible Exchange (SABRE) hyperpolarization of the rare isotopes in “neat” liquids, each composed only of an otherwise pure target compound with isotopic natural abundance (n.a.) and millimolar concentrations of dissolved catalyst. Pyridine (Py) or Py derivatives are studied at 0.4% isotopic natural abundance 15N, deuterated, 15N enriched, and in various combinations using the SABRE-SHEATH variant (microTesla magnetic fields to permit direct 15N polarization from parahydrogen via reversible binding and exchange with an Ir catalyst). We find that the dilute n.a. 15N spin bath in Py still channels spin order from parahydrogen to dilute 15N spins, without polarization losses due to the presence of 14N or 2H. We demonstrate P15N ≈ 1% (a gain of 2900 fold relative to thermal polarization at 9.4 T) at high substrate concentrations. This fundamental finding has a significant practical benefit for screening potentially hyperpolarizable contrast agents without labeling. The capability of screening at n.a. level of 15N is demonstrated on examples of mono- and dimethyl-substituted Py (picolines and lutidines previously identified as promising pH sensors), showing that the presence of a methyl group in the ortho position significantly decreases SABRE hyperpolarization. PMID:26029349
The Evaluation of Micro Teaching Method Used in the Training of Primary School Teachers in Turkey
ERIC Educational Resources Information Center
Musa, Taskaya Serdarhan
2014-01-01
Micro teaching, one of the most frequently used methods in the pre-service education of teachers, is used in many lectures for the training of teachers in the faculties of education in Turkey. Micro teaching is a teaching method which is especially used in the pre-service training of teachers and it aims to train prospective teachers by making…
Evaporation-based Ge/.sup.68 Ga Separation
Mirzadeh, Saed; Whipple, Richard E.; Grant, Patrick M.; O'Brien, Jr., Harold A.
1981-01-01
Micro concentrations of .sup.68 Ga in secular equilibrium with .sup.68 Ge in strong aqueous HCl solution may readily be separated in ionic form from the .sup.68 Ge for biomedical use by evaporating the solution to dryness and then leaching the .sup.68 Ga from the container walls with dilute aqueous solutions of HCl or NaCl. The chloro-germanide produced during the evaporation may be quantitatively recovered to be used again as a source of .sup.68 Ga. If the solution is distilled to remove any oxidizing agents which may be present as impurities, the separation factor may easily exceed 10.sup.5. The separation is easily completed and the .sup.68 Ga made available in ionic form in 30 minutes or less.
Seely, R J; Krueger, R D; Fahrney, D E
1983-11-15
Methanobacterium thermoautotrophicum was grown in phosphate-limited chemostat cultures at a dilution rate corresponding to a doubling time of 13.2 h. The cyclic-2,3-diphospho-D-glycerate content of these cells was 8 to 10-fold lower than that of cells grown in batch cultures having a doubling time of 11.5 h. This metabolite accounted for 5% of cell dry weight during batch growth on 2 mM phosphate. In the chemostat the steady-state concentration of phosphate was 4 microM, showing that this methanogen is adapted to highly efficient growth at low phosphate concentrations. Since growth rates were similar in both cultures, the growth rate clearly does not depend on intracellular levels of cyclic-2,3-diphosphoglycerate.
Micro-Employees Employment, Enhanced Oil-Recovery Improvement
NASA Astrophysics Data System (ADS)
Allahtavakoli, M.; Allahtavakoli, Y.
2009-04-01
Employment of Micro-organisms, as profitable micro-employees in improvement of Enhanced Oil Recovery (EOR), leads us to a famous method named "MEOR". Applying micro-organisms in MEOR makes it more lucrative than other EOR ways because feeding these micro-employees is highly economical and their metabolic processes require some cheap food-resources such as molasses. In addition, utilizing the local micro-organism in reservoirs will reduce the costs effectively; Furthermore these micro-organisms are safety and innocuous to some extent. In MEOR, the micro-organisms are always employed for two purposes, "Restoring pressure to reservoir" and "Decreasing Oil-Viscosity". As often as more, the former is achievable by In-Situ Mechanism or by applying the micro-organisms producing Biopolymers and the latter is also reachable by applying the micro-organisms producing Bio-surfactants. This paper as a proposal which was propounded to National Iranian Oil Company (NIOC) is an argument for studying and reviewing "Interaction between Micro-organisms and Reservoir physiochemical properties", "Biopolymer producers and Bio-Surfactant Producers", "In-Situ Mechanism", "Proposed Methods in MEOR" and their limitations.
Rodriguez-Jorquera, Ignacio A.; Silva-Sanchez, Cecilia; Strynar, Mark; Denslow, Nancy D.; Toor, Gurpal S.
2016-01-01
Current approaches to protect biodiversity by establishing protected areas usually gloss over water pollution as a threat. Our objective was to determine the longitudinal and seasonal distribution of perfluoroalkyl acids (PFAAs) in water column and sediments from a wastewater dominated stream that enters preservation areas. Water samples were collected along the longitudinal section (six sites, 1000 m away from each other) of the stream during the dry and wet seasons. Sediments were collected from three sites along the stream from three depths. Water and sediments were analyzed for PFAAs using high performance liquid chromatography-tandem mass spectrometry. Eleven PFAAs with 5 to 14 carbon atoms were detected in the water column at all sampling points, with a minor reduction at the last point suggesting a dilution effect. The most detected PFAAs was PFOS, followed by perfluorooctanoic acid (PFOA), and perfluorohexanoic acid (PFHxA). Seasonal differences in PFAAs concentrations suggested contribution of stormwater runoff during the wet season. All analyzed PFAAs in sediments were under the limit of quantification, likely due to the high proportion of sand and low organic matter. However, high concentrations of PFAAs were detected in the water column inside the protected areas, which includes PFOS in concentrations considered not safe for avian wildlife. Water samples appear to be more relevant than sediments to determine PFAAs micro-pollution in water bodies with sandy sediments. Inclusion of a management plans on micro-pollution research, monitoring, and mitigation is recommended for protected areas. PMID:26909512
Thermal Decomposition of Methyl Acetate (CH_3COOCH_3) in a Flash-Pyrolysis Micro-Reactor
NASA Astrophysics Data System (ADS)
Porterfield, Jessica P.; Bross, David H.; Ruscic, Branko; Thorpe, James H.; Nguyen, Thanh Lam; Baraban, Joshua H.; Stanton, John F.; Daily, John W.; Ellison, Barney
2017-06-01
The thermal decomposition of methyl acetate (CH_3COOCH_3) has been studied in a set of flash pyrolysis micro-reactors. Samples were diluted to (0.06 - 0.13%) in carrier gases (He, Ar) and subjected to temperatures of 300 - 1600 K at roughly 20 Torr. After residence times of approximately 25 - 150 μseconds, the unimolecular pyrolysis products were detected by vacuum ultraviolet photoionization mass spectrometry at 10.487 eV (118.2 nm). Complementary product identification was provided by matrix isolation infrared spectroscopy. Decomposition began at 1000 K with the observation of (CH_2=C=O, CH_3OH), products of a four centered rearrangement with a Δ_{rxn}H_{298} = 39.1 ± 0.2 kcal mol^{-1}. As the micro-reactor was heated to 1300 K, a mixture of (CH_2=C=O, CH_3OH, CH_3, CH_2=O, H, CO, CO_2) appeared. A new novel pathway is calculated in which both methyl groups leave behind CO_2 simultaneously, Δ_{rxn}H_{298} = 74.5 ± 0.4 kcal mol^{-1}. This pathway is in contrast to step-wise loss of methyl radical, which can go in two ways: Δ_{rxn}H_{298} (CH_3COOCH_3 → CH_3 + COOCH_3) = 95.4 ± 0.4 kcal mol^{-1}, Δ_{rxn}H_{298} (CH_3COOCH_3 → CH_3COO + CH_3) = 88.0 ± 0.3 kcal mol^{-1}.
Huang, Wanfeng; Chang, Chun-Li; Brault, Norman D; Gur, Onur; Wang, Zhe; Jalal, Shadia I; Low, Philip S; Ratliff, Timothy L; Pili, Roberto; Savran, Cagri A
2017-01-31
Current efforts for the detection of prostate cancer using only prostate specific antigen are not ideal and indicate a need to develop new assays - using multiple targets - that can more accurately stratify disease states. We previously introduced a device capable of the concurrent detection of cellular and molecular markers from a single sample fluid. Here, an improved design, which achieves affinity as well as size-based separation of captured targets using antibody-conjugated magnetic beads and a silicon chip containing micro-apertures, is presented. Upon injection of the sample, the integration of magnetic attraction with the micro-aperture chip permits larger cell-bead complexes to be isolated in an upper chamber with the smaller protein-bead complexes and remaining beads passing through the micro-apertures into the lower chamber. This enhances captured cell purity for on chip quantification, allows the separate retrieval of captured cells and proteins for downstream analysis, and enables higher bead concentrations for improved multiplexed ligand targeting. Using LNCaP cells and prostate specific membrane antigen (PSMA) to model prostate cancer, the device was able to detect 34 pM of spiked PSMA and achieve a cell capture efficiency of 93% from culture media. LNCaP cells and PSMA were then spiked into diluted healthy human blood to mimic a cancer patient. The device enabled the detection of spiked PSMA (relative to endogenous PSMA) while recovering 85-90% of LNCaP cells which illustrated the potential of new assays for the diagnosis of prostate cancer.
Commutability of Cytomegalovirus WHO International Standard in Different Matrices
Jones, Sara; Webb, Erika M.; Barry, Catherine P.; Choi, Won S.; Abravaya, Klara B.; Schneider, George J.
2016-01-01
Commutability of quantitative standards allows patient results to be compared across molecular diagnostic methods and laboratories. This is critical to establishing quantitative thresholds for use in clinical decision-making. A matrix effect associated with the 1st cytomegalovirus (CMV) WHO international standard (IS) was identified using the Abbott RealTime CMV assay. A commutability study was performed to compare the CMV WHO IS and patient specimens diluted in plasma and whole blood. Patient specimens showed similar CMV DNA quantitation values regardless of the diluent or extraction procedure used. The CMV WHO IS, on the other hand, exhibited a matrix effect. The CMV concentration reported for the WHO IS diluted in plasma was within the 95% prediction interval established with patient samples. In contrast, the reported DNA concentration of the CMV WHO IS diluted in whole blood was reduced approximately 0.4 log copies/ml, and values fell outside the 95% prediction interval. Calibrating the assay by using the CMV WHO IS diluted in whole blood would introduce a bias for CMV whole-blood quantitation; samples would be reported as having higher measured concentrations, by approximately 0.4 log IU/ml. Based on the commutability study with patient samples, the RealTime CMV assay was standardized based on the CMV WHO IS diluted in plasma. A revision of the instructions for use of the CMV WHO IS should be considered to alert users of the potential impact from the diluent matrix. The identification of a matrix effect with the CMV WHO IS underscores the importance of assessing commutability of the IS in order to achieve consistent results across methods. PMID:27030491
Study on the engine oil's wear based on the flash point
NASA Astrophysics Data System (ADS)
Niculescu, R.; Iorga-Simăn, V.; Trică, A.; Clenci, A.
2016-08-01
Increasing energy performance of internal combustion engines is largely influenced by frictional forces that arise between moving parts. Thus, in this respect, the nature and quality of the engine oil used is an important factor. Equally important is the effect of various engine injection strategies upon the oil quality. In other words, it's of utmost importance to maintain the quality of engine oil during engine's operation. Oil dilution is one of the most common causes that lead to its wear, creating lubrication problems. Moreover, at low temperatures operating conditions, the oil dilution with diesel fuel produces wax. When starting the engine, this may lead to lubrication deficiencies and even oil starvation with negative consequences on the engine mechanism parts wear (piston, rings and cylinders) but also crankcase bearings wear.Engine oil dilution with diesel fuel have several causes: wear of rings and/or injectors, late post-injection strategy for the sake of particulate filter regeneration, etc.This paper presents a study on the degree of deterioration of engine oils as a result of dilution with diesel fuel. The analysed oils used for this study were taken from various models of engines equipped with diesel particulate filter. The assessment is based on the determination of oil flash point and dilution degree using the apparatus Eraflash produced by Eralytics, Austria. Eraflash measurement is directly under the latest and safest standards ASTM D6450 & D7094), which are in excellent correlation with ASTM D93 Pensky - Martens ASTM D56 TAG methods; it uses the Continuous Closed Cup method for finding the Flash Point (CCCFP).
Stark, Peter C.; Kuske, Cheryl R.; Mullen, Kenneth I.
2002-01-01
A method for quantitating dsDNA in an aqueous sample solution containing an unknown amount of dsDNA. A first aqueous test solution containing a known amount of a fluorescent dye-dsDNA complex and at least one fluorescence-attenutating contaminant is prepared. The fluorescence intensity of the test solution is measured. The first test solution is diluted by a known amount to provide a second test solution having a known concentration of dsDNA. The fluorescence intensity of the second test solution is measured. Additional diluted test solutions are similarly prepared until a sufficiently dilute test solution having a known amount of dsDNA is prepared that has a fluorescence intensity that is not attenuated upon further dilution. The value of the maximum absorbance of this solution between 200-900 nanometers (nm), referred to herein as the threshold absorbance, is measured. A sample solution having an unknown amount of dsDNA and an absorbance identical to that of the sufficiently dilute test solution at the same chosen wavelength is prepared. Dye is then added to the sample solution to form the fluorescent dye-dsDNA-complex, after which the fluorescence intensity of the sample solution is measured and the quantity of dsDNA in the sample solution is determined. Once the threshold absorbance of a sample solution obtained from a particular environment has been determined, any similarly prepared sample solution taken from a similar environment and having the same value for the threshold absorbance can be quantified for dsDNA by adding a large excess of dye to the sample solution and measuring its fluorescence intensity.
Dual Temporal Scale Convolutional Neural Network for Micro-Expression Recognition.
Peng, Min; Wang, Chongyang; Chen, Tong; Liu, Guangyuan; Fu, Xiaolan
2017-01-01
Facial micro-expression is a brief involuntary facial movement and can reveal the genuine emotion that people try to conceal. Traditional methods of spontaneous micro-expression recognition rely excessively on sophisticated hand-crafted feature design and the recognition rate is not high enough for its practical application. In this paper, we proposed a Dual Temporal Scale Convolutional Neural Network (DTSCNN) for spontaneous micro-expressions recognition. The DTSCNN is a two-stream network. Different of stream of DTSCNN is used to adapt to different frame rate of micro-expression video clips. Each stream of DSTCNN consists of independent shallow network for avoiding the overfitting problem. Meanwhile, we fed the networks with optical-flow sequences to ensure that the shallow networks can further acquire higher-level features. Experimental results on spontaneous micro-expression databases (CASME I/II) showed that our method can achieve a recognition rate almost 10% higher than what some state-of-the-art method can achieve.
NASA Technical Reports Server (NTRS)
Thomas, R. R.
1976-01-01
Two methods for eliminating luminol interference materials are described. One method eliminates interference from organic material by pre-reacting a sample with dilute hydrogen peroxide. The reaction rate resolution method for eliminating inorganic forms of interference is also described. The combination of the two methods makes the luminol system more specific for bacteria. Flow system designs for both the firefly luciferase and luminol bacteria detection systems are described. The firefly luciferase flow system incorporating nitric acid extraction and optimal dilutions has a functional sensitivity of 3 x 100,000 E. coli/ml. The luminol flow system incorporates the hydrogen peroxide pretreatment and the reaction rate resolution techniques for eliminating interference. The functional sensitivity of the luminol flow system is 1 x 10,000 E. coli/ml.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Amano, H.
1959-10-01
The determination of tantalum by the isotope dilution method in the presence of niobium was investigated by the use of the radioisotope Ta/sup 185/. Tantalum was separated from niobium as tantalum-tannin precipitate under the optimum conditions of a pH of 1.9 to 2.5 and a tantalum/niobium ratio of up to 1/ 50. If niobium was present in amounts 100 times or more that of tantalum, reprecipitation was needed. The reciprocal of the specific activity of tanthlum pentoxide precipitate was in a linear relation to the change in the amount of tantalum added. The recommended method gave an accurate result inmore » the determination of tantalum in steal. (auth)« less
Hutchinson, Donald P.; Richards, Roger K.
2003-07-22
A micro-laser is disclosed which includes a waveguide, a first and a second subwavelength resonant grating in the waveguide, and at least one photonic band gap resonant structure (PBG) in the waveguide and at least one amplifying medium in the waveguide. PBG features are positioned between the first and second subwavelength resonant gratings and allow introduction of amplifying mediums into the highly resonant guided micro-laser microcavity. The micro-laser may be positioned on a die of a bulk substrate material with one or more electronic and optical devices and may be communicably connected to the same. A method for fabricating a micro-laser is disclosed. A method for tuning the micro-laser is also disclosed. The micro-laser may be used as an optical regenerator, or a light source for data transfer or for optical computing.
Trapping of a micro-bubble by non-paraxial Gaussian beam: computation using the FDTD method.
Sung, Seung-Yong; Lee, Yong-Gu
2008-03-03
Optical forces on a micro-bubble were computed using the Finite Difference Time Domain method. Non-paraxial Gaussian beam equation was used to represent the incident laser with high numerical aperture, common in optical tweezers. The electromagnetic field distribution around a micro-bubble was computed using FDTD method and the electromagnetic stress tensor on the surface of a micro-bubble was used to compute the optical forces. By the analysis of the computational results, interesting relations between the radius of the circular trapping ring and the corresponding stability of the trap were found.
Light propagation in the micro-size capillary injected by high temperature liquid
NASA Astrophysics Data System (ADS)
Li, Yan-jun; Li, Edward; Xiao, Hai
2016-11-01
The high temperature liquid is injected into the micro-size capillary and its light propagation behavior is investigated. We focus on two different liquid pumping methods. The first method can pump the high temperature liquid tin into the micro-size capillary by using a high pressure difference system. After pumping, a single mode fiber (SMF) connected with the optical carrier based microwave interferometry (OCMI) system is used to measure different liquid tin levels in the micro-size capillary. The second method can pump the room temperature engine oil into the capillary by using a syringe pump. This method can avoid the air bubbles when the liquids are pumped into the capillary.
Chang, Chih-Chun; Su, Ming-Jang; Ho, Jung-Li; Tsai, Yu-Hui; Tsai, Wei-Ting; Lee, Shu-Jene; Yen, Tzung-Hai; Chu, Fang-Yeh
2016-01-01
Urine protein detection could be underestimated using the conventional dipstick method because of variations in urine aliquots. This study aimed to assess the efficacy of the semi-quantitative urine protein-to-creatinine (P/C) ratio compared with other laboratory methods. Random urine samples were requested from patients undergoing chronic kidney disease screening. Significant proteinuria was determined by the quantitative P/C ratio of at least 150 mg protein/g creatinine. The semi-quantitative P/C ratio, dipstick protein and quantitative protein concentrations were compared and analyzed. In the 2932 urine aliquots, 156 (5.3 %) urine samples were considered as diluted and 60 (39.2 %) were found as significant proteinuria. The semi-quantitative P/C ratio testing had the best sensitivity (70.0 %) and specificity (95.9 %) as well as the lowest underestimation rate (0.37 %) when compared to other laboratory methods in the study. In the semi-quantitative P/C ratio test, 19 (12.2 %) had positive, 52 (33.3 %) had diluted, and 85 (54.5 %) had negative results. Of those with positive results, 7 (36.8 %) were positive detected by traditional dipstick urine protein test, and 9 (47.4 %) were positive detected by quantitative urine protein test. Additionally, of those with diluted results, 25 (48.1 %) had significant proteinuria, and all were assigned as no significant proteinuria by both tests. The semi-quantitative urine P/C ratio is clinically applicable based on its better sensitivity and screening ability for significant proteinuria than other laboratory methods, particularly in diluted urine samples. To establish an effective strategy for CKD prevention, urine protein screening with semi-quantitative P/C ratio could be considered.
[Formation of oxalate in oxaliplatin injection diluted with infusion solutions].
Eto, Seiji; Yamamoto, Kie; Shimazu, Kounosuke; Sugiura, Toshimune; Baba, Kaori; Sato, Ayaka; Goromaru, Takeshi; Hagiwara, Yoshiaki; Hara, Keiko; Shinohara, Yoshitake; Takahashi, Kojiro
2014-01-01
Oxaliplatin use can cause acute peripheral neuropathy characterized by sensory paresthesias, which are markedly exacerbated by exposure to cold temperatures, and is a dose-limiting factor in the treatment of colorectal cancer.Oxalate is eliminated in a series of nonenzymatic conversions of oxaliplatin in infusion solutions or biological fluids.Elimination of oxalate from oxaliplatin has been suggested as one of the reasons for the development of acute neuropathy.In this study, we developed a high-performance liquid chromatography(HPLC)-based method to detect oxalate formation, and investigated the time dependent formation of oxalate in oxaliplatin diluted with infusion solutions.The results obtained showed that the amount of oxalate in the solution corresponded to 1.6% of oxaliplatin 8 h after oxaliplatin dilution with a 5% glucose solution. On the other hand, oxalate formation from oxaliplatin diluted with a saline solution was ten-fold higher than that from oxaliplatin diluted with the 5% glucose solution.Most patients who were intravenously injected with oxaliplatin experienced venous pain.As a preventive measure against venous pain, dexamethasone was added to the oxaliplatin injection.We measured the amount of oxalate formed in the dexamethasone-containing oxaliplatin injection diluted with a 5% glucose solution.The amount of oxalate formed when dexamethasone was added did not differ significantly from that formed when dexamethasone was not added.Thus, there are no clinical problems associated with the stability of oxaliplatin solutions.
A Study of the Vacancy-Impurity Interaction in Dilute Nickel Alloys by Core Electron Annihilation
NASA Astrophysics Data System (ADS)
Arbuzov, V. L.; Danilov, S. E.; Druzhkov, A. P.
1997-08-01
It is shown that the angular correlation of annihilation radiation can be used to identify vacancy-impurity complexes in dilute alloys. Annihilation of trapped positrons with core electrons bears information about the chemical environment of a vacancy defect. The method is especially effective for d-matrices doped with sp-impurities since annihilation parameters of positrons with d- and sp-shell electrons differ considerably. The potentialities of the method of core-electron annihilation of positrons are demonstrated taking electron-irradiated dilute Ni-P and Ni-Si alloys as an example. It is shown that the interaction between the vacancies, which migrate at the III stage of annealing, and P atoms in Ni-P causes a considerable change in the annihilation parameters of positrons with core electrons compared to pure Ni. In Ni-Si alloys the annihilation parameters of trapped positrons with core electrons do not differ from those in Ni. This fact is an evidence that Si atoms do not interact with vacancies in Ni.
Chan, George C. Y. [Bloomington, IN; Hieftje, Gary M [Bloomington, IN
2010-08-03
A method for detecting and correcting inaccurate results in inductively coupled plasma-atomic emission spectrometry (ICP-AES). ICP-AES analysis is performed across a plurality of selected locations in the plasma on an unknown sample, collecting the light intensity at one or more selected wavelengths of one or more sought-for analytes, creating a first dataset. The first dataset is then calibrated with a calibration dataset creating a calibrated first dataset curve. If the calibrated first dataset curve has a variability along the location within the plasma for a selected wavelength, errors are present. Plasma-related errors are then corrected by diluting the unknown sample and performing the same ICP-AES analysis on the diluted unknown sample creating a calibrated second dataset curve (accounting for the dilution) for the one or more sought-for analytes. The cross-over point of the calibrated dataset curves yields the corrected value (free from plasma related errors) for each sought-for analyte.
Plackett-Burman and Box-Behnken designs as chemometric tools for micro-determination of L-Ornithine
NASA Astrophysics Data System (ADS)
Elazazy, Marwa S.; El-Hamshary, Marwa; Sakr, Marwa; Al-Easa, Hala S.
2018-03-01
Plackett-Burman (PB) and Box-Behnken (BB) screening and response surface factorial designs were used to evaluate spectrophotometric and spectrofluorimetric approaches for the determination of L-Ornithine (ORN) as per se and in dietary supplements. Both approaches were based on the derivatization of the primary amino group of ORN via Hantzsch condensation reaction producing yellow coloured adducts (dihydrolutidine derivative). The reaction product was determined spectrophotometrically (method A) at λmax = 327 nm and spectrofluorimetrically (method B) at 480 nm (λem) after excitation at 325 nm (λex). A multivariate scheme was tailored to investigate the process numerical variables; reaction temperature, heating time, reagent volume, and pH implementing PB as a screening design followed by BB as an optimization strategy. Categorical factors including diluting solvent and sequence of addition were kept invariable. Responses of the reaction systems were the maximum absorbance (Y1) and maximum fluorescence intensity (Y2), correspondingly. Quality tools as well as ANOVA testing, before and after response transformation were used to decide upon the substantial variables. Following the optimization of reaction variables using desirability plots, calibration graphs were found to be rectilinear in the range of 6-14 μg/mL and 0.4-1.2 μg/mL for methods A and B, respectively. Both methods proved to be sensitive with detection limits (DL) of 337 and 85 ng/mL, and quantitation limits (QL) of 1086 and 283 ng/mL, for methods A and B, respectively. An interference study was performed using potential foreign species. No significant interference effect was observed on any of the proposed procedures. System performance was addressed following ICH guidelines and considering parameters such as linearity, detection and quantification limits, accuracy and precision, robustness and specificity.
Baltch, A L; Smith, R P; Ritz, W
1995-01-01
The susceptibilities of 56 Legionella pneumophila isolates (43 clinical and 15 environmental isolates) to levofloxacin, ofloxacin, erythromycin, and rifampin were studied with buffered charcoal yeast extract (BCYE) agar (inoculum, 10(4) CFU per spot), and the susceptibilities of five isolates were studied with buffered yeast extract (BYE) broth (inoculum, 10(5) CFU/ml). The MICs inhibiting 90% of strains tested on BCYE agar were 0.125, 0.25, 1.0, and < or = 0.004 micrograms/ml for levofloxacin, ofloxacin, erythromycin, and rifampin, respectively. The MICs by the BYE broth dilution method were 1 to 3, 2, 1 to 2, and 1 tube lower than those by the agar dilution method for levofloxacin, ofloxacin, erythromycin, and rifampin, respectively. The MBCs were 1 to 2 tubes higher than the broth dilution MICs for levofloxacin, 1 to 3 tubes higher than the broth dilution MICs for ofloxacin, 1 to 3 tubes higher than the broth dilution MICs for erythromycin, and the same as the broth dilution MICs for rifampin. In kinetic time-kill curve studies, at drug concentrations of 1.0 and 2.0 times the MIC, the most active drugs were levofloxacin and rifampin. At 72 h, concentrations of levofloxacin and rifampin of 2.0 times the MIC demonstrated a bactericidal effect against L. pneumophila. In contrast, at concentrations of 1.0 and 2.0 times the MICs regrowth was observed with ofloxacin and only a gradual decrease in the numbers of CFU per milliliter was observed with erythromycin. Only a minor inhibitory effect was observed with 0.25 or 0.5 time the MICs of all drugs at 24 to 48 h, with regrowth occurring at 72 h. In contrast to erythromycin or ofloxacin plus rifampin at 0.25 time the MICs, only levofloxacin plus rifampin demonstrated synergy. Thus, levofloxacin demonstrated the best inhibitory and bactericidal effects against L. pneumophila when it was studied alone or in a combination with rifampin. PMID:7486896
Fernández-Fernández, Mario; Rodríguez-González, Pablo; Añón Álvarez, M Elena; Rodríguez, Felix; Menéndez, Francisco V Álvarez; García Alonso, J Ignacio
2015-04-07
This work describes the first multiple spiking isotope dilution procedure for organic compounds using (13)C labeling. A double-spiking isotope dilution method capable of correcting and quantifying the creatine-creatinine interconversion occurring during the analytical determination of both compounds in human serum is presented. The determination of serum creatinine may be affected by the interconversion between creatine and creatinine during sample preparation or by inefficient chemical separation of those compounds by solid phase extraction (SPE). The methodology is based on the use differently labeled (13)C analogues ((13)C1-creatinine and (13)C2-creatine), the measurement of the isotopic distribution of creatine and creatinine by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and the application of multiple linear regression. Five different lyophilized serum-based controls and two certified human serum reference materials (ERM-DA252a and ERM-DA253a) were analyzed to evaluate the accuracy and precision of the proposed double-spike LC-MS/MS method. The methodology was applied to study the creatine-creatinine interconversion during LC-MS/MS and gas chromatography-mass spectrometry (GC-MS) analyses and the separation efficiency of the SPE step required in the traditional gas chromatography-isotope dilution mass spectrometry (GC-IDMS) reference methods employed for the determination of serum creatinine. The analysis of real serum samples by GC-MS showed that creatine-creatinine separation by SPE can be a nonquantitative step that may induce creatinine overestimations up to 28% in samples containing high amounts of creatine. Also, a detectable conversion of creatine into creatinine was observed during sample preparation for LC-MS/MS. The developed double-spike LC-MS/MS improves the current state of the art for the determination of creatinine in human serum by isotope dilution mass spectrometry (IDMS), because corrections are made for all the possible errors derived from the sample preparation step.
A simple method for the comparison of commercially available ATP hygiene-monitoring systems.
Colquhoun, K O; Timms, S; Fricker, C R
1998-04-01
The purpose of this study was to evaluate a methodology which could easily be used in any test laboratory in a uniform and consistent way for determining the sensitivity and reproducibility of results obtained with three ATP hygiene-monitoring systems. The test protocol discussed here allows such comparison to be made, thereby establishing a method of benchmarking both new systems and developments of existing systems. The sensitivity of the LUMINOMETER K, PocketSwab (Charm Sciences) was found to be between 0.4 and 4.0 nmol of ATP with poor reproducibility at the 40.0 nmol level (CV, 35%). The sensitivity of the IDEXX LIGHTING system and the Biotrace UNILITE Xcel were both between 0.04 and 0.4 nmol with coefficients of variation (CVs) of between 9% at 0.04 nmol and 10% at 0.4 nmol for the IDEXX system and 17% at 0.04 nmol and 21% at 0.4 nmol for the Biotrace system. The three systems were tested with a range of dilutions of different food residues: orange juice, raw milk, and ground beef slurry. All three test systems allowed detection of orange juice and raw milk at dilutions of 1:1,000, although the CV of results from the Charm system (54 and 74% respectively) was poor at this dilution for both residues. The sensitivity of the test systems was poorer for ground beef slurry than it was for orange juice and raw milk. Both the Biotrace and IDEXX systems were able to detect a 1:100 dilution of beef slurry (with CVs of 17 and 10% respectively), whilst at this dilution results from the Charm system had a CV of 55%. It was possible by using the method described in this paper to rank in order of sensitivity and reproducibility the three single-shot ATP hygiene-monitoring systems investigated, with the IDEXX LIGHTNING being the best, followed by the Biotrace UNILITE Xcel, and then the charm LUMINOMETER K, PocketSwab.
Arendrup, Maiken Cavling; Garcia-Effron, Guillermo; Lass-Flörl, Cornelia; Lopez, Alicia Gomez; Rodriguez-Tudela, Juan-Luis; Cuenca-Estrella, Manuel; Perlin, David S.
2010-01-01
This study compared nine susceptibility testing methods and 12 endpoints for anidulafungin, caspofungin, and micafungin with the same collection of blinded FKS hot spot mutant (n = 29) and wild-type isolates (n = 94). The susceptibility tests included EUCAST Edef 7.1, agar dilution, Etest, and disk diffusion with RPMI-1640 plus 2% glucose (2G) and IsoSensitest-2G media and CLSI M27A-3. Microdilution plates were read after 24 and 48 h. The following test parameters were evaluated: fks hot spot mutants overlapping the wild-type distribution, distance between the two populations, number of very major errors (VMEs; fks mutants misclassified as susceptible), and major errors (MEs; wild-type isolates classified as resistant) using a wild-type-upper-limit value (WT-UL) (two twofold-dilutions higher than the MIC50) as the susceptibility breakpoint. The methods with the lowest number of errors (given as VMEs/MEs) across the three echinocandins were CLSI (12%/1%), agar dilution with RPMI-2G medium (14%/0%), and Etest with RPMI-2G medium (8%/3%). The fewest errors overall were observed for anidulafungin (4%/1% for EUCAST, 4%/3% for CLSI, and 3%/9% for Etest with RPMI-2G). For micafungin, VME rates of 10 to 71% were observed. For caspofungin, agar dilution with either medium was superior (VMEs/MEs of 0%/1%), while CLSI, EUCAST with IsoSensitest-2G medium, and Etest were less optimal (VMEs of 7%, 10%, and 10%, respectively). Applying the CLSI breakpoint (S ≤ 2 μg/ml) for CLSI results, 89.2% fks hot spot mutants were classified as anidulafungin susceptible, 60.7% as caspofungin susceptible, and 92.9% as micafungin susceptible. In conclusion, no test was perfect, but anidulafungin susceptibility testing using the WT-UL to define susceptibility reliably identified fks hot spot mutants. PMID:19884370
Rosenbloom, Daniel I S; Elliott, Oliver; Hill, Alison L; Henrich, Timothy J; Siliciano, Janet M; Siliciano, Robert F
2015-12-01
Limiting dilution assays are widely used in infectious disease research. These assays are crucial for current human immunodeficiency virus (HIV)-1 cure research in particular. In this study, we offer new tools to help investigators design and analyze dilution assays based on their specific research needs. Limiting dilution assays are commonly used to measure the extent of infection, and in the context of HIV they represent an essential tool for studying latency and potential curative strategies. Yet standard assay designs may not discern whether an intervention reduces an already miniscule latent infection. This review addresses challenges arising in this setting and in the general use of dilution assays. We illustrate the major statistical method for estimating frequency of infectious units from assay results, and we offer an online tool for computing this estimate. We recommend a procedure for customizing assay design to achieve desired sensitivity and precision goals, subject to experimental constraints. We consider experiments in which no viral outgrowth is observed and explain how using alternatives to viral outgrowth may make measurement of HIV latency more efficient. Finally, we discuss how biological complications, such as probabilistic growth of small infections, alter interpretations of experimental results.
da Silva, Yvana Lopes Pinheiro; Costa, Rita Zanlorensi Visneck; Pinho, Kátia Elisa Prus; Ferreira, Ricardo Rabello; Schuindt, Sueliton Miyamoto
2015-01-01
Objective To investigate the effects of dilution of paramagnetic contrast agent with iodinated contrast and xylocaine on the signal intensity during magnetic resonance arthrography, and to improve the paramagnetic contrast agent concentration utilized in this imaging modality. Materials and Methods Samples specially prepared for the study with three different concentrations of paramagnetic contrast agent diluted in saline, iodinated contrast agent and xylocaine were imaged with fast spin echo T1-weighted sequences with fat saturation. The samples were placed into flasks and graphical analysis of the signal intensity was performed as a function of the paramagnetic contrast concentration. Results As compared with samples of equal concentrations diluted only with saline, the authors have observed an average signal intensity decrease of 20.67% for iodinated contrast agent, and of 28.34% for xylocaine. However, the increased gadolinium concentration in the samples caused decrease in signal intensity with all the dilutions. Conclusion Minimizing the use of iodinated contrast media and xylocaine and/or the use of a gadolinium concentration of 2.5 mmol/L diluted in saline will improve the sensitivity of magnetic resonance arthrography. PMID:25987746
Detection of viability of micro-algae cells by optofluidic hologram pattern.
Wang, Junsheng; Yu, Xiaomei; Wang, Yanjuan; Pan, Xinxiang; Li, Dongqing
2018-03-01
A rapid detection of micro-algae activity is critical for analysis of ship ballast water. A new method for detecting micro-algae activity based on lens-free optofluidic holographic imaging is presented in this paper. A compact lens-free optofluidic holographic imaging device was developed. This device is mainly composed of a light source, a small through-hole, a light propagation module, a microfluidic chip, and an image acquisition and processing module. The excited light from the light source passes through a small hole to reach the surface of the micro-algae cells in the microfluidic chip, and a holographic image is formed by the diffraction light of surface of micro-algae cells. The relation between the characteristics in the hologram pattern and the activity of micro-algae cells was investigated by using this device. The characteristics of the hologram pattern were extracted to represent the activity of micro-algae cells. To demonstrate the accuracy of the presented method and device, four species of micro-algae cells were employed as the test samples and the comparison experiments between the alive and dead cells of four species of micro-algae were conducted. The results show that the developed method and device can determine live/dead microalgae cells accurately.
Wang, Shuoliang; Liu, Pengcheng; Zhao, Hui; Zhang, Yuan
2017-11-29
Micro-tube experiment has been implemented to understand the mechanisms of governing microcosmic fluid percolation and is extensively used in both fields of micro electromechanical engineering and petroleum engineering. The measured pressure difference across the microtube is not equal to the actual pressure difference across the microtube. Taking into account the additional pressure losses between the outlet of the micro tube and the outlet of the entire setup, we propose a new method for predicting the dynamic capillary pressure using the Level-set method. We first demonstrate it is a reliable method for describing microscopic flow by comparing the micro-model flow-test results against the predicted results using the Level-set method. In the proposed approach, Level-set method is applied to predict the pressure distribution along the microtube when the fluids flow along the microtube at a given flow rate; the microtube used in the calculation has the same size as the one used in the experiment. From the simulation results, the pressure difference across a curved interface (i.e., dynamic capillary pressure) can be directly obtained. We also show that dynamic capillary force should be properly evaluated in the micro-tube experiment in order to obtain the actual pressure difference across the microtube.
NASA Astrophysics Data System (ADS)
Papadopoulou, D. N.; Zachariadis, G. A.; Anthemidis, A. N.; Tsirliganis, N. C.; Stratis, J. A.
2004-12-01
Two multielement instrumental methods of analysis, micro X-ray fluorescence spectrometry (micro-XRF) and inductively coupled plasma atomic emission spectrometry (ICP-AES) were applied for the analysis of 7th and 5th century B.C. ancient ceramic sherds in order to evaluate the above two methods and to assess the potential to use the current compact and portable micro-XRF instrument for the in situ analysis of ancient ceramics. The distinguishing factor of interest is that micro-XRF spectrometry offers the possibility of a nondestructive analysis, an aspect of primary importance in the compositional analysis of cultural objects. Micro-XRF measurements were performed firstly directly on the ceramic sherds with no special pretreatment apart from surface cleaning (micro-XRF on sherds) and secondly on pressed pellet disks which were prepared for each ceramic sherd (micro-XRF on pellet). For the ICP-AES determination of elements, test solutions were prepared by the application of a microwave-assisted decomposition procedure in closed high-pressure PFA vessels. Also, the standard reference material SARM 69 was used for the efficiency calibration of the micro-XRF instrument and was analysed by both methods. In order to verify the calibration, the standard reference materials NCS DC 73332 and SRM620 as well as the reference materials AWI-1 and PRI-1 were analysed by micro-XRF. Elemental concentrations determined by the three analytical procedures (ICP-AES, micro-XRF on sherds and micro-XRF on pellets) were statistically treated by correlation analysis and Student's t-test (at the 95% confidence level).
Interior micro-CT with an offset detector
Sharma, Kriti Sen; Gong, Hao; Ghasemalizadeh, Omid; Yu, Hengyong; Wang, Ge; Cao, Guohua
2014-01-01
Purpose: The size of field-of-view (FOV) of a microcomputed tomography (CT) system can be increased by offsetting the detector. The increased FOV is beneficial in many applications. All prior investigations, however, have been focused to the case in which the increased FOV after offset-detector acquisition can cover the transaxial extent of an object fully. Here, the authors studied a new problem where the FOV of a micro-CT system, although increased after offset-detector acquisition, still covers an interior region-of-interest (ROI) within the object. Methods: An interior-ROI-oriented micro-CT scan with an offset detector poses a difficult reconstruction problem, which is caused by both detector offset and projection truncation. Using the projection completion techniques, the authors first extended three previous reconstruction methods from offset-detector micro-CT to offset-detector interior micro-CT. The authors then proposed a novel method which combines two of the extended methods using a frequency split technique. The authors tested the four methods with phantom simulations at 9.4%, 18.8%, 28.2%, and 37.6% detector offset. The authors also applied these methods to physical phantom datasets acquired at the same amounts of detector offset from a customized micro-CT system. Results: When the detector offset was small, all reconstruction methods showed good image quality. At large detector offset, the three extended methods gave either visible shading artifacts or high deviation of pixel value, while the authors’ proposed method demonstrated no visible artifacts and minimal deviation of pixel value in both the numerical simulations and physical experiments. Conclusions: For an interior micro-CT with an offset detector, the three extended reconstruction methods can perform well at a small detector offset but show strong artifacts at a large detector offset. When the detector offset is large, the authors’ proposed reconstruction method can outperform the three extended reconstruction methods by suppressing artifacts and maintaining pixel values. PMID:24877826
CHRONOS: a time-varying method for microRNA-mediated subpathway enrichment analysis.
Vrahatis, Aristidis G; Dimitrakopoulou, Konstantina; Balomenos, Panos; Tsakalidis, Athanasios K; Bezerianos, Anastasios
2016-03-15
In the era of network medicine and the rapid growth of paired time series mRNA/microRNA expression experiments, there is an urgent need for pathway enrichment analysis methods able to capture the time- and condition-specific 'active parts' of the biological circuitry as well as the microRNA impact. Current methods ignore the multiple dynamical 'themes'-in the form of enriched biologically relevant microRNA-mediated subpathways-that determine the functionality of signaling networks across time. To address these challenges, we developed time-vaRying enriCHment integrOmics Subpathway aNalysis tOol (CHRONOS) by integrating time series mRNA/microRNA expression data with KEGG pathway maps and microRNA-target interactions. Specifically, microRNA-mediated subpathway topologies are extracted and evaluated based on the temporal transition and the fold change activity of the linked genes/microRNAs. Further, we provide measures that capture the structural and functional features of subpathways in relation to the complete organism pathway atlas. Our application to synthetic and real data shows that CHRONOS outperforms current subpathway-based methods into unraveling the inherent dynamic properties of pathways. CHRONOS is freely available at http://biosignal.med.upatras.gr/chronos/ tassos.bezerianos@nus.edu.sg Supplementary data are available at Bioinformatics online. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Wang, Yan; Ren, Wenxuan; Gao, Dong; Wang, Lili; Yang, Ying; Bai, Quan
2015-02-01
Protein refolding is a key step for the production of recombinant proteins, especially at large scales, and usually their yields are very low. Chromatographic-based protein refolding techniques have proven to be superior to conventional dilution refolding methods. High refolding yield can be achieved using these methods compared with dilution refolding of proteins. In this work, recombinant human tumor necrosis factor-α (rhTNF-α) from inclusion bodies expressed in Escherichia coli was renatured with simultaneous purification by ion exchange chromatography with a DEAE Sepharose FF column. Several chromatographic parameters influencing the refolding yield of the denatured/reduced rhTNF-α, such as the urea concentration, pH value and concentration ratio of glutathione/oxidized glutathione in the mobile phase, were investigated in detail. Under optimal conditions, rhTNF-α can be renatured and purified simultaneously within 30 min by one step. Specific bioactivity of 2.18 × 10(8) IU/mg, purity of 95.2% and mass recovery of 76.8% of refolded rhTNF-α were achieved. Compared with the usual dilution method, the ion exchange chromatography method developed here is simple and more effective for rhTNF-α refolding in terms of specific bioactivity and mass recovery. Copyright © 2014 John Wiley & Sons, Ltd.
Hohnadel, Marisa; Maumy, Myriam; Chollet, Renaud
2018-01-01
For nearly a century, conventional microbiological methods have been standard practice for detecting and identifying pathogens in food. Nevertheless, the microbiological safety of food has improved and various rapid methods have been developed to overcome the limitations of conventional methods. Alternative methods are expected to detect low cell numbers, since the presence in food of even a single cell of a pathogenic organism may be infectious. With respect to low population levels, the performance of a detection method is assessed by producing serial dilutions of a pure bacterial suspension to inoculate representative food matrices with highly diluted bacterial cells (fewer than 10 CFU/ml). The accuracy of data obtained by multiple dilution techniques is not certain and does not exclude some colonies arising from clumps of cells. Micromanipulation techniques to capture and isolate single cells from environmental samples were introduced more than 40 years ago. The main limitation of the current micromanipulation technique is still the low recovery rate for the growth of a single cell in culture medium. In this study, we describe a new single cell isolation method and demonstrate that it can be used successfully to grow various types of microorganism from picked individual cells. Tests with Gram-positive and Gram-negative organisms, including cocci, rods, aerobes, anaerobes, yeasts and molds showed growth recovery rates from 60% to 100% after micromanipulation. We also highlight the use of our method to evaluate and challenge the detection limits of standard detection methods in food samples contaminated by a single cell of Salmonella enterica.
Micro and nano liposome vesicles containing curcumin for a drug delivery system
NASA Astrophysics Data System (ADS)
Nguyen, Tuan Anh; Duoc Tang, Quan; Chanh Tin Doan, Duc; Chien Dang, Mau
2016-09-01
Micro and nano liposome vesicles were prepared using a lipid film hydration method and a sonication method. Phospholipid, cholesterol and curcumin were used to form micro and nano liposomes containing curcumin. The size, structure and properties of the liposomes were characterized by using optical microscopy, transmission electron microscopy, and UV-vis and Raman spectroscopy. It was found that the size of the liposomes was dependent on their composition and the preparation method. The hydration method created micro multilamellars, whereas nano unilamellars were formed using the sonication method. By adding cholesterol, the vesicles of the liposome could be stabilized and stored at 4 °C for up to 9 months. The liposome vesicles containing curcumin with good biocompatibility and biodegradability could be used for drug delivery applications.