NASA Astrophysics Data System (ADS)
Devès, Guillaume; Cohen-Bouhacina, Touria; Ortega, Richard
2004-10-01
We used the nuclear microprobe techniques, micro-PIXE (particle-induced X-ray emission), micro-RBS (Rutherford backscattering spectrometry) and scanning transmission ion microscopy (STIM) in order to perform the characterization of trace element content and spatial distribution within biological samples (dehydrated cultured cells, tissues). The normalization of PIXE results was usually expressed in terms of sample dry mass as determined by micro-RBS recorded simultaneously to micro-PIXE. However, the main limit of RBS mass measurement is the sample mass loss occurring during irradiation and which could be up to 30% of the initial sample mass. We present here a new methodology for PIXE normalization and quantitative analysis of trace element within biological samples based on dry mass measurement performed by mean of STIM. The validation of STIM cell mass measurements was obtained in comparison with AFM sample thickness measurements. Results indicated the reliability of STIM mass measurement performed on biological samples and suggested that STIM should be performed for PIXE normalization. Further information deriving from direct confrontation of AFM and STIM analysis could as well be obtained, like in situ measurements of cell specific gravity within cells compartment (nucleolus and cytoplasm).
Quantitative analysis of major elements in silicate minerals and glasses by micro-PIXE
Campbell, J.L.; Czamanske, G.K.; MacDonald, L.; Teesdale, W.J.
1997-01-01
The Guelph micro-PIXE facility has been modified to accommodate a second Si(Li) X-ray detector which records the spectrum due to light major elements (11 ??? Z ??? 20) with no deleterious effects from scattered 3 MeV protons. Spectra have been recorded from 30 well-characterized materials, including a broad range of silicate minerals and both natural and synthetic glasses. Sodium is mobile in some of the glasses, but not in the studied mineral lattices. The mean value of the instrumental constant H for each of the elements Mg, Al, and Si in these materials is systematically 6-8% lower than the H-value measured for the pure metals. Normalization factors are derived which permit the matrix corrections requisite for trace-element measurements in silicates to be based upon pure metal standards for Mg, Al and Si, supplemented by well-established, silicate mineral standards for the elements Na, K and Ca. Rigorous comparisons of electron microprobe and micro-PIXE analyses for the entire, 30-sample suite demonstrate the ability of micro-PIXE to produce accurate analysis for the light major elements in silicates. ?? 1997 Elsevier Science B.V.
Enhanced identification of trace element fingerprint of prehistoric pigments by PIXE mapping
NASA Astrophysics Data System (ADS)
Lebon, M.; Pichon, L.; Beck, L.
2018-02-01
The elemental composition of Fe rich rocks used as pigment during prehistoric periods can provide valuable information about the type of material used and their geological origin. However, these materials present several analytical constraints since their patrimonial value involve using non-invasive techniques maintaining a high sensitivity of the detection and the quantification of trace elements. Micro-beam techniques also require to take into account the heterogeneity of these geomaterials from the macroscopic to microscopic scales. Several previous studies have demonstrated that PIXE analysis satisfies these analytical conditions. However, application of micro-PIXE analysis is still complex when thin and discontinuous layer of pigment is deposed on the surface of other materials such as rocks or bones. In such case, PIXE imaging could improve the ability to take into account the high heterogeneity of such archaeological objects. In study, we used PIXE imaging system developed at the NewAGLAE facility in order to visualize distribution of elements associated with iron-rich pigment phase. The results obtained show that PIXE maps can improve the identification of the main trace elements specific to the iron mineral phase. By grouping pixels of iron-rich areas and performing quantitative treatment, it was possible to reveal additional trace elements associated to pigment. This study highlights the contribution of PIXE imaging to the identification of elements associated with mineral phases of interest and to use them as proxies to discriminate different geological materials used in archaeological context.
Long term fine aerosol analysis by XRF and PIXE techniques in the city of Rijeka, Croatia
NASA Astrophysics Data System (ADS)
Ivošević, Tatjana; Orlić, Ivica; Radović, Iva Bogdanović
2015-11-01
The results of a long term, multi elemental XRF and PIXE analysis of fine aerosol pollution in the city of Rijeka, Croatia, are reported for the first time. The samples were collected during a seven months period (6th Aug 2013-28th Feb 2014) on thin stretched Teflon filters and analyzed by energy dispersive X-ray fluorescence (EDXRF) at the Laboratory for Elemental Micro-Analysis (LEMA), University of Rijeka and by Particle Induced X-ray Emission (PIXE) using 1.6 MeV protons at the Laboratory for Ion Beam Interactions (LIBI), Ruđer Bošković Institute, Zagreb. The newly developed micro-XRF system at LEMA provided results for 19 elements in the range from Si to Pb. The PIXE at the LIBI provided information for the same elements as well for the light elements such as Na, Mg and Al. Black carbon was determined with the Laser Integrated Plate Method (LIPM). The results were statistically evaluated by means of the positive matrix factorization (PMF). The seven major pollution sources were identified together with their relative contributions, these are: secondary sulfates, road traffic, smoke, road dust, sea spray, ship emissions and soil dust.
NASA Astrophysics Data System (ADS)
Tkalec, Živa Pipan; Drobne, Damjana; Vogel-Mikuš, Katarina; Pongrac, Paula; Regvar, Marjana; Štrus, Jasna; Pelicon, Primož; Vavpetič, Primož; Grlj, Nataša; Remškar, Maja
2011-10-01
Micro-proton induced X-ray emission (micro-PIXE) method was applied to study the micro-localization of silver (Ag) in digestive glands of a terrestrial arthropod (Porcellio scaber) after feeding on silver nanoparticles (nano-Ag) dosed food. The aim of our work was to assess whether feeding on nano-Ag results in the assimilation of silver (Ag) in digestive gland cells. To study micro-localization and elemental distribution of Ag, the animals were fed on food dosed with nanoparticles for 14 days under controlled laboratory conditions. At the end of the feeding exposure, the animals were dissected and digestive glands prepared for micro-PIXE analyses and TEM investigation. The results obtained by micro-PIXE documented high amounts of Ag inside S-cells of the digestive gland epithelium; however, TEM investigation did not show particle aggregates inside digestive gland cells. Also no adverse effect on feeding behavior was recorded what is a measure of toxic effects. We explain the presence of Ag inside the cells as a result of the assimilation of dissoluted Ag ions from ingested nano-Ag particles. Assimilation of excessive amounts of ingested metal ions in S-cells is a well known metal detoxification mechanism in isopods. We discuss the advantages of using micro-PIXE for the micro-localization of elements in biological tissue in studies of interactions between nanoparticles and biological systems.
Usewear studies of flint tools with microPIXE and microRBS
NASA Astrophysics Data System (ADS)
Christensen, Marianne; Grime, Geoff; Menu, Michel; Walter, Philippe
1993-05-01
The use of ancient stone tools leaves a polish (usewear) on the cutting edge which can be studied to determine the material the tool had worked during its use. The film is formed by high pressure intrusion of the worked material into the microcavities of the chipped flint surface and so the film can also be analysed directly to determine the nature of the worked material. This paper describes the analysis of experimental flint tools which had worked bone and ivory using microbeam PIXE and RBS. It is found that PIXE used simultaneously with RBS allows the thickness and composition of the film to be determined and ivory distinguished from bone while RBS mapping allows the three-dimensional structure of the film to be determined.
NASA Astrophysics Data System (ADS)
Ndimba, R.; Cloete, K.; Mehlo, L.; Kossmann, J.; Mtshali, C.; Pineda-Vargas, C.
2017-08-01
In the present study, possible differences in the mineral composition of transgenic versus non-transgenic sorghum grains were investigated using inductively coupled atomic emission spectroscopy (ICP-AES); and, in-tissue elemental mapping by micro Proton-Induced X-ray Emission (micro-PIXE) analysis. ICP AES was used to analyse the bulk mineral content of the wholegrain flour derived from each genotype; whilst micro-PIXE was used to interrogate localised differences in mineral composition specific to certain areas of the grain, such as the bran layer and the central endosperm tissue. According to the results obtained, no significant difference in the average Fe, Zn or Ca content was found to differentiate the transgenic from the wild-type grain using ICP-AES. However, using micro-PIXE, a significant reduction in zinc could be detected in the bran layer of the transgenic grains relative to wild-type. Although it is difficult to draw firm conclusions, as a result of the small sample size used in this study, micro-PIXE has nonetheless proven itself as a useful technique for highlighting the possibility that there may be reduced levels of zinc accumulation in the bran layer of the transgenic grains. Given that the genetic modification targets proteins that are highly concentrated in certain parts of the bran tissue, it seems plausible that the reduced levels of zinc may be an unintended consequence of the silencing of kafirin proteins. Although no immediate health or nutritional concerns emerge from this preliminary finding, it is noted that zinc plays an important biological role within this part of the grain as a structural stabiliser and antioxidant factor. Further study is therefore needed to assess more definitively the extent of the apparent localised reduction in zinc in the transgenic grains and how this may affect other important grain quality characteristics.
NASA Astrophysics Data System (ADS)
Nxumalo, V.; Kramers, J.; Mongwaketsi, N.; Przybyłowicz, W. J.
2017-08-01
Uranium occurrence and characterisation in the coal samples of the upper coal zones of the Vryheid Formation and mudstones of the Volksrust Formation was investigated using micro-PIXE (Proton-Induced X-ray Emission) and proton backscattering spectrometry (BS) in conjunction with the nuclear microprobe. Two styles of uranium mineralisation in the Springbok Flats Basin were found: syngenetic mineralisation in which uranium occurs organically bound with coal matrix, with no discrete uranium minerals formed, and epigenetic mineralisation in which uranium occurs in veins that are filled with coffinite with botryoidal texture in the mudstones of the Volksrust Formation, overlying the coal zones. Micro-PIXE analysis made it possible to map out trace elements (including uranium) associated with the coals at low levels of detection, which other techniques such as SEM-EDS and ore microscopy failed. This information will help in better understanding of the best extraction methods to be employed to recover uranium from the coals of the Springbok Flats Basin.
He, Xiaodong; Shen, Hao; Chen, Zidan; Rong, Caicai; Ren, Minqin; Hou, Likun; Wu, Chunyan; Mao, Ling; Lu, Quan; Su, Bo
2017-12-01
Pneumoconiosis is an occupational disease accompanied by long-term lung impairment, for which prediction of prognosis is poorly understood because of the complexity of the inhaled particles. Micro-proton-induced X-ray emission (micro-PIXE) analysis, which is advantageous for high-sensitivity, two-dimensional element mapping of lung tissues, was used to investigate element-based predictive factors of prognosis in Chinese patients with welder's and coal miner's pneumoconiosis. Chest radiographs and lung function tests showed that most of the coal miners deteriorated, whereas symptoms in some welders were alleviated after 5 yr, as determined by comparing percent vital capacity (%VC) and forced expiratory volume in the 1st second over forced vital capacity (FEV1.0/FVC) to values taken at the initial diagnosis. Micro-PIXE analysis suggested that the most abundant particulates in welder's pneumoconiosis were Fe, Mn, and Ti (metallic oxide),which were accompanied by particulates containing Si, Al, and Ca (aluminum silicate) or only Si (SiO 2 ); the most abundant particulates in coal miner's pneumoconiosis were composed of C, Si, Al, K, and Ti, which were accompanied by particulates containing Ca or Fe. Particulates containing Al, Si, S, K, Ca, and Ti (orthoclase and anorthite) were correlated with severity of fibrosis. Multivariable linear regression suggested that long-term FEV1.0/FVC decrease was independently associated with Si and smoking index, whereas %VC decrease was associated with Si and Ti. A risk index comprised of these factors was developed to predict the prognosis of pneumoconiosis. Micro-PIXE analysis is feasible for the evaluation of elemental composition and dust exposure, especially for patients whose exposure is mixed or uncertain. Copyright © 2017 the American Physiological Society.
Micro-PIXE evaluation of radioactive cesium transfer in contaminated soil samples
NASA Astrophysics Data System (ADS)
Fujishiro, F.; Ishii, K.; Matsuyama, S.; Arai, H.; Ishizaki, A.; Osada, N.; Sugai, H.; Kusano, K.; Nozawa, Y.; Yamauchi, S.; Karahashi, M.; Oshikawa, S.; Kikuchi, K.; Koshio, S.; Watanabe, K.; Suzuki, Y.
2014-01-01
Micro-PIXE analysis has been performed on two soil samples with high cesium activity concentrations. These soil samples were contaminated by fallout from the accident at Fukushima Daiichi Nuclear Power Plant. One exhibits a radioactive cesium transfer of ˜0.01, and the other shows a radioactive cesium transfer of less than 0.001, even though both samples have high cesium activity concentrations exceeding 10,000 Bq/kg. X-ray spectra and elemental images of the soil samples revealed the presence of chlorine, which can react with cesium to produce an inorganic soluble compound, and phosphorus-containing cesium-capturable organic compounds.
Pineda-Vargas, C A; Eisa, M E M; Rodgers, A L
2009-03-01
The micro-PIXE and RBS techniques are used to investigate the matrix as well as the trace elemental composition of calcium-rich human tissues on a microscopic scale. This paper deals with the spatial distribution of trace metals in hard human tissues such as kidney stone concretions, undertaken at the nuclear microprobe (NMP) facility. Relevant information about ion beam techniques used for material characterization will be discussed. Mapping correlation between different trace metals to extract information related to micro-regions composition will be illustrated with an application using proton energies of 1.5 and 3.0 MeV and applied to a comparative study for human kidney stone concretions nucleation region analysis from two different population groups (Sudan and South Africa).
Ahmad, Muthanna; Grime, Geoffrey W
2013-04-01
Porous silicon (PS) has been prepared using a microwave-assisted hydrofluoric acid (HF) etching method from a silicon wafer pre-implanted with 5 MeV Cu ions. The use of microbeam proton-induced X-ray emission (micro-PIXE) and microbeam Rutherford backscattering techniques reveals for the first time the capability of these techniques for studying the formation of micropores. The porous structures observed from micro-PIXE imaging results are compared to scanning electron microscope images. It was observed that the implanted copper accumulates in the same location as the pores and that at high implanted dose the pores form large-scale patterns of lines and concentric circles. This is the first work demonstrating the use of microwave-assisted HF etching in the formation of PS.
NASA Astrophysics Data System (ADS)
Kachenko, Anthony G.; Siegele, Rainer; Bhatia, Naveen P.; Singh, Balwant; Ionescu, Mihail
2008-04-01
Hybanthus floribundus subsp. floribundus, a rare Australian Ni-hyperaccumulating shrub and Pityrogramma calomelanos var. austroamericana, an Australian naturalized As-hyperaccumulating fern are promising species for use in phytoremediation of contaminated sites. Micro-proton-induced X-ray emission (μ-PIXE) spectroscopy was used to map the elemental distribution of the accumulated metal(loid)s, Ca and K in leaf or pinnule tissues of the two plant species. Samples were prepared by two contrasting specimen preparation techniques: freeze-substitution in tetrahydrofuran (THF) and freeze-drying. The specimens were analysed to compare the suitability of each technique in preserving (i) the spatial elemental distribution and (ii) the tissue structure of the specimens. Further, the μ-PIXE results were compared with concentration of elements in the bulk tissue obtained by ICP-AES analysis. In H. floribundus subsp. floribundus, μ-PIXE analysis revealed Ni, Ca and K concentrations in freeze-dried leaf tissues were at par with bulk tissue concentrations. Elemental distribution maps illustrated that Ni was preferentially localised in the adaxial epidermal tissues (1% DW) and least concentration was found in spongy mesophyll tissues (0.53% DW). Conversely, elemental distribution maps of THF freeze-substituted tissues indicated significantly lower Ni, Ca and K concentrations than freeze-dried specimens and bulk tissue concentrations. Moreover, Ni concentrations were uniform across the whole specimen and no localisation was observed. In P. calomelanos var. austroamericana freeze-dried pinnule tissues, μ-PIXE revealed statistically similar As, Ca and K concentrations as compared to bulk tissue concentrations. Elemental distribution maps showed that As localisation was relatively uniform across the whole specimen. Once again, THF freeze-substituted tissues revealed a significant loss of As compared to freeze-dried specimens and the concentrations obtained by bulk tissue analysis. The results demonstrate that freeze-drying is a suitable sample preparation technique to study elemental distribution of ions in H. floribundus and P. calomelanos plant tissues using μ-PIXE spectroscopy. Furthermore, cellular structure was preserved in samples prepared using this technique.
Micro-PIXE mapping of mineral distribution in mature grain of two pearl millet cultivars
NASA Astrophysics Data System (ADS)
Minnis-Ndimba, R.; Kruger, J.; Taylor, J. R. N.; Mtshali, C.; Pineda-Vargas, C. A.
2015-11-01
Micro-proton-induced X-ray emission (micro-PIXE) was used to map the distribution of several nutritionally important minerals found in the grain tissue of two cultivars of pearl millet (Pennisetum glaucum (L.) R. Br.). The distribution maps revealed that the predominant localisation of minerals was within the germ (consisting of the scutellum and embryo) and the outer grain layers (specifically the pericarp and aleurone); whilst the bulk of the endosperm tissue featured relatively low concentrations of the surveyed minerals. Within the germ, the scutellum was revealed as a major storage tissue for P and K, whilst Ca, Mn and Zn were more prominent within the embryo. Fe was revealed to have a distinctive distribution pattern, confined to the dorsal end of the scutellum; but was also highly concentrated in the outer grain layers. Interestingly, the hilar region was also revealed as a site of high accumulation of minerals, particularly for S, Ca, Mn, Fe and Zn, which may be part of a defensive strategy against infection or damage. Differences between the two cultivars, in terms of the bulk Fe and P content obtained via inductively coupled plasma optical emission spectrometry (ICP-OES), concurred with the average concentration data determined from the analysis of micro-PIXE spectra specifically extracted from the endosperm tissue.
Lomonte, Cristina; Wang, Yaodong; Doronila, Augustine; Gregory, David; Baker, Alan J M; Siegele, Rainer; Kolev, Spas D
2014-01-01
Localization of Hg in root tissues of vetivergrass (Chrysopogon zizanioides) was investigated by micro-Proton Induced X-ray Emission (PIXE) spectrometry to gain a better understanding of Hg uptake and its translocation to the aerial plant parts. Tillers of C. zizanioides were grown in a hydroponic culture for 3 weeks under controlled conditions and then exposed to Hg for 10 days with or without the addition of the chelators (NH(4))(2)S(2)O(3) or KI. These treatments were used to study the effects of these chelators on localization of Hg in the root tissues to allow better understanding of Hg uptake during its assisted-phytoextraction. Qualitative elemental micro-PIXE analysis revealed that Hg was mainly localized in the root epidermis and exodermis, tissues containing suberin in all Hg treatments. Hg at trace levels was localized in the vascular bundle when plants were treated with a mercury solution only. However, higher Hg concentrations were found when the solution also contained (NH(4))(2)S(2)O(3) or KI. This finding is consistent with the observed increase in Hg translocation to the aerial parts of the plants in the case of chemically induced Hg phytoextraction.
NASA Astrophysics Data System (ADS)
Sanchez, J. L.; Osipowicz, T.; Tang, S. M.; Tay, T. S.; Win, T. T.
1997-07-01
The trace element concentrations found in geological samples can shed light on the formation process. In the case of gemstones, which might be of artificial or natural origin, there is also considerable interest in the development of methods that provide identification of the origin of a sample. For rubies, trace element concentrations present in natural samples were shown previously to be significant indicators of the region of origin [S.M. Tang et al., Appl. Spectr. 42 (1988) 44, and 43 (1989) 219]. Here we report the results of micro-PIXE analyses of trace element (Ti, V, Cr, Fe, Cu and Ga) concentrations of a large set ( n = 130) of natural rough rubies from nine locations in Myanmar (Burma). The resulting concentrations are subjected to statistical analysis. Six of the nine groups form clusters when the data base is evaluated using tree clustering and principal component analysis.
Micro-PIXE investigation of bean seeds to assist micronutrient biofortification
NASA Astrophysics Data System (ADS)
Cvitanich, Cristina; Przybyłowicz, Wojciech J.; Mesjasz-Przybyłowicz, Jolanta; Blair, Matthew W.; Astudillo, Carolina; Orłowska, Elżbieta; Jurkiewicz, Anna M.; Jensen, Erik Ø.; Stougaard, Jens
2011-10-01
This study compares the distribution and concentrations of micro- and macronutrients in different bean cultivars with the aim of optimizing the biofortification, a sustainable approach towards improving dietary quality. Micro-PIXE was used to reveal the distribution of Fe, Zn, Mn, Ca, P, S in seeds of common beans (Phaseolus vulgaris) and runner beans (Phaseolus coccineus). Average concentrations of elements in different tissues were obtained using ICP-AES. The highest concentrations of Zn in the studied beans were found in the embryonic axis, but an increased concentration of this element was also detected in the provascular bundles of the cotyledons. The first layer of cells surrounding provascular bundles accumulated high concentrations of Fe, while the next cell layer had an increased concentration of Mn. The analysis showed that the provascular bundles and the first cell layers surrounding them could have a significant role in the storage of important seed micronutrients - Zn, Fe, and Mn. This information has important implications for molecular biology studies aimed at seed biofortification.
PIXE analysis of Italian ink drawings of the XVI century
NASA Astrophysics Data System (ADS)
Zucchiatti, A.; Climent-Font, A.; Enguita, O.; Fernandez-Jimenez, M. T.; Finaldi, G.; Garrido, C.; Matillas, J. M.
2005-10-01
The composition of inks in a group of 24 drawings of ten XVI century Italian painters, has been determined by PIXE at the external micro-beam line of the Centro de Micro Análisis de Materiales of the Universidad Autónoma de Madrid. Ink elemental thicknesses have been determined by comparison with a set of certified thin standards. A comprehensive comparison of inks has also been performed by renormalisation of spectra and definition of an ink-to-ink distance. The elemental compositions and the ink-to-ink distances give consistent results that are generally in line with the appearance of the drawings and add relevant instrumental information to the stylistic observation, revealing for example the presence of retouches and additions in different parts of a drawing. Cluster analysis performed on a subgroup of 13 artefacts from the Genoese painter Luca Cambiaso and his school has revealed a partition that separates neatly the work of the master from that of his followers.
NASA Astrophysics Data System (ADS)
Habermann, D.; Götte, T.; Meijer, J.; Stephan, A.; Richter, D. K.; Niklas, J. R.
2000-03-01
The rare-earth element (REE) distribution in natural apatite is analysed by micro-PIXE, cathodoluminescence (CL) microscopy and spectroscopy and electron spin resonance (ESR) spectroscopy. The micro-PIXE analyses of an apatite crystal from Cerro de Mercado (Mexico) and the summary of 20 analyses of six francolite (conodonts of Triassic age) samples indicate that most of the REEs are enriched in apatite and francolite comparative to average shale standard (NASC). The analyses of fossil francolite revealing the REE-distribution not to be in balance with the REE-distribution of seawater and fish bone debris. Strong inhomogenous lateral REE-distribution in fossil conodont material is shown by CL-mapping and most probably not being a vital effect. Therefore, the resulting REE-signal from fossil francolite is the sum of vital and post-mortem incorporation. The necessary charge compensation for the substitution of divalent Ca by trivalent REE being done by different kind of electron defects and defect ions.
NASA Astrophysics Data System (ADS)
Rombouts, P. M. M.; Gomez-Morilla, I.; Grime, G. W.; Webb, R. P.; Cuenca, L.; Rodriguez, R.; Browton, M.; Wardell, N.; Underwood, B.; Kirkby, N. F.; Kirkby, K. J.
2007-07-01
Schizosaccharomyces pombe ( S. pombe) is a eucaryotic cell type similar to mammalian cells but much more simple. As it also executes its cell cycle rapidly it is very useful for investigating basic processes in cells. In this paper we report a feasibility study of the applicability of microPIXE to investigate the interaction between S. pombe cells and the surrounding culture medium. Cells were cultured in various growth medium prior to preparation for analysis. 1 μl drops of medium and cells were spotted onto polypropylene foils held in contact with a polished copper block previously cooled in liquid nitrogen. The samples were dehydrated by freeze-drying. Micro PIXE analysis was carried out with the IBC microbeam facility using a beam of 2.5 MeV protons focused to 1-2 μm diameter. Initially no elemental contrast was observed between the cells and the medium, but by modifying the dilution of the cell suspension, the cells could be distinguished from the surrounding medium through an increased concentration of P and reduced concentration of Cl. The distribution of Na in the medium around the cells showed evidence of the action of the Na pump. Sporulation appears to be induced in the cells by adding Cu to the growth medium and the uptake of Cu by the cells could be clearly observed. This study shows that it is possible to analyse the mass transport of elements in and out of cells In the future this will enable concentration gradients to be analysed and allow the rate of production or consumption of individual cells to be calculated. By observing these patterns for individual cells (not populations) at various known points in the cell cycle, fundamental data can be derived.
NASA Astrophysics Data System (ADS)
Mouton, M.; Botha, A.; Thornton, M.; Mesjasz-Przybyłowicz, J.; Przybyłowicz, W. J.
2015-11-01
Several studies revealed that anthropogenic activities often cause toxic concentrations of some elements, such as mercury, which bio-accumulate through the marine food chain, impacting negatively on the health of animals in the top trophic levels, such as a variety of marine mammals. Moreover, analysis of cetacean skin has been reported to be a reliable, long-term and mostly non-invasive method to monitor bio-accumulation of chemicals in cetacean populations. Several elements, including trace elements, occur naturally in cetacean skin, although nothing is known about their distribution patterns and little about safe base line concentrations. In May 2009, 42 false killer whales (FKWs) beached and died at Kommetjie in the Western Cape of South Africa. Skin samples of these FKWs were collected and analysed to determine elemental distribution patterns. The concentrations and distribution patterns of the major, as well as detectable trace elements were determined in skin samples from ten randomly selected FKW individuals, using micro-PIXE (particle-induced X-ray emission) analysis. Results revealed differences between the distribution patterns of elements in the skin sections. Fe, for example, was found to be concentrated in the dermal papillae, whereas the highest Zn concentrations occurred in the epidermis and particularly in the epidermal papillae. Since these essential elements mediate factors such as host immunity, from skin integrity to humoral immunity, knowledge of their typical distribution patterns can be of great value in studies of bio-accumulation. This is the first report of micro-PIXE being employed to study elemental distribution in cetacean skin and the resulting elemental distribution maps can serve as reference in future environmental pollution studies.
Scanning-PIXE analysis of gold lace embroideries in a relic of St. Francis
NASA Astrophysics Data System (ADS)
Migliori, A.; Grassi, N.; Mandò, P. A.
2008-05-01
In this work, we describe the compositional analysis performed by scanning-mode PIXE on the metal threads of a XIII century embroidery. The precious work analysed is the pillow-case used to cover the pillow, on which - according to tradition - St. Francis of Assisi was resting his head when he died. Measurements were performed in order to characterise the embroideries of the two sides and the passementerie in the lateral hems. Several areas, each of the order of two square millimetres, were scanned with a 3 MeV proton external beam of 20 μm size on target, using the external micro-beam facility of our laboratory, with list-mode acquisition. Analysis of elemental maps and spectra from selected homogeneous sub-areas allowed us to extract the quantitative composition of the gilded tape and estimates of its thickness.
Ortega, Richard; Devès, Guillaume; Carmona, Asunción
2009-01-01
The direct detection of biologically relevant metals in single cells and of their speciation is a challenging task that requires sophisticated analytical developments. The aim of this article is to present the recent achievements in the field of cellular chemical element imaging, and direct speciation analysis, using proton and synchrotron radiation X-ray micro- and nano-analysis. The recent improvements in focusing optics for MeV-accelerated particles and keV X-rays allow application to chemical element analysis in subcellular compartments. The imaging and quantification of trace elements in single cells can be obtained using particle-induced X-ray emission (PIXE). The combination of PIXE with backscattering spectrometry and scanning transmission ion microscopy provides a high accuracy in elemental quantification of cellular organelles. On the other hand, synchrotron radiation X-ray fluorescence provides chemical element imaging with less than 100 nm spatial resolution. Moreover, synchrotron radiation offers the unique capability of spatially resolved chemical speciation using micro-X-ray absorption spectroscopy. The potential of these methods in biomedical investigations will be illustrated with examples of application in the fields of cellular toxicology, and pharmacology, bio-metals and metal-based nano-particles. PMID:19605403
NASA Astrophysics Data System (ADS)
Yamamoto, H.; Iwami, Y.; Yagi, K.; Hayashi, M.; Komatsu, H.; Okuyama, K.; Matsuda, Y.; Yasuda, K.
2015-04-01
It is well-known that fluorine (F) is involved in the progression of caries. The evaluation of caries progression has conventionally been based on the change in mineral content using transverse microradiography (TMR). The purpose of this study was to evaluate the progression of dentinal caries by the change in calcium (Ca) content using Particle-Induced Gamma-ray Emission/Particle-Induced X-ray Emission (PIGE/PIXE) techniques at the Wakasa Wan Energy Research Center. We also assessed the relationship between caries progression rate and the concentration of F penetration into dentin from dental fluoride-containing materials (FCMs). Dentin sections of six extracted human teeth were prepared to obtain various amounts of F uptake using three types of FCMs. F and Ca distribution of specimens were obtained using PIGE/PIXE techniques. After evaluation, the specimens were immersed in 10 ml of demineralizing solution (pH 4.5) to simulate caries attack. To estimate caries progression rates, the same portions of the specimens were evaluated after caries attack treatment using PIGE/PIXE. A negative correlation between the F uptake in dentin and the rate of caries progression was observed. Therefore, caries progression in dentin was reduced by increasing the amount of F uptake from FCMs. This demonstrates that PIGE/PIXE techniques are valuable for estimating caries progression rates.
Study of Italian Renaissance sculptures using an external beam nuclear microprobe
NASA Astrophysics Data System (ADS)
Zucchiatti, A.; Bouquillon, A.; Moignard, B.; Salomon, J.; Gaborit, J. R.
2000-03-01
The use of an extracted proton micro-beam for the PIXE analysis of glazes is discussed in the context of the growing interest in the creation of an analytical database on Italian Renaissance glazed terracotta sculptures. Some results concerning the frieze of an altarpiece of the Louvre museum, featuring white angels and cherubs heads, are presented.
NASA Astrophysics Data System (ADS)
Colombo, E.; Calusi, S.; Cossio, R.; Giuntini, L.; Giudice, A. Lo; Mandò, P. A.; Manfredotti, C.; Massi, M.; Mirto, F. A.; Vittone, E.
2008-04-01
A new ionoluminescence (IL) apparatus has been successfully installed at the external scanning microbeam facility of the 3 MV Tandetron accelerator of the INFN LABEC in Firenze; the apparatus for photon detection has been fully integrated in the existing ion beam analysis (IBA) set-up, for the simultaneous acquisition of IL and PIXE/PIGE/BS spectra and maps. The potential of the new set-up is illustrated in this paper by some results extracted by the analysis of art objects and advanced semiconductor materials. In particular, the adequacy of the new IBA set-up in the field of cultural heritage is pointed out by the coupled PIXE/IL micro-analysis of a lapis lazuli stone; concerning applications in material science, IL spectra from a N doped diamond sample were acquired and compared with CL analyses to evaluate the relevant sensitivities and the effect of ion damage.
Cadmium localization and quantification in the plant Arabidopsis thaliana using micro-PIXE
NASA Astrophysics Data System (ADS)
Ager, F. J.; Ynsa, M. D.; Domínguez-Solís, J. R.; Gotor, C.; Respaldiza, M. A.; Romero, L. C.
2002-04-01
Remediation of metal-contaminated soils and waters poses a challenging problem due to its implications in the environment and the human health. The use of metal-accumulating plants to remove toxic metals, including Cd, from soil and aqueous streams has been proposed as a possible solution to this problem. The process of using plants for environmental restoration is termed phytoremediation. Cd is a particularly favourable target metal for this technology because it is readily transported and accumulated in the shoots of several plant species. This paper investigates the sites of metal localization within Arabidopsis thaliana leaves, when plants are grown in a cadmium-rich environment, by making use of nuclear microscopy techniques. Micro-PIXE, RBS and SEM analyses were performed on the scanning proton microprobe at the CNA in Seville (Spain), showing that cadmium is sequestered within the trichomes on the leaf surface. Additionally, regular PIXE analyses were performed on samples prepared by an acid digestion method in order to assess the metal accumulation of such plants.
Development of a new in-air micro-PIXE set-up with in-vacuum charge measurements in Atomki
NASA Astrophysics Data System (ADS)
Török, Zs.; Huszánk, R.; Csedreki, L.; Dani, J.; Szoboszlai, Z.; Kertész, Zs.
2015-11-01
A new external microbeam set-up has recently been installed as the extension of the existing microprobe system at the Laboratory of Ion Beam Applications of Atomki, Debrecen, Hungary. The external beam set-up, based on the system of Oxford Microbeams (OM), is equipped with two X-ray detectors for PIXE analysis, a digital microscope, two alignment lasers and a precision XYZ stage for easy and reproducible positioning of the sample. Exit windows with different thicknesses and of different materials can be used according to the actual demands, currently silicon-nitride (Si3N4) film with 200 nm thickness is employed in our laboratory. The first application was demonstrated in the field of archaeometry, on Bronze Age hoards from Hungary.
Calvo del Castillo, H; Deprez, N; Dupuis, T; Mathis, F; Deneckere, A; Vandenabeele, P; Calderón, T; Strivay, D
2009-06-01
Differentiation of treated and non-treated gemstones is a chief concern for major jewellery import companies. Low-quality corundum specimens coming from Asia appear to be often treated with heat, BeO or flux in order to enhance their properties as precious minerals. A set of corundum samples, rubies and sapphires from different origins, both treated and non-treated has been analysed at the Centre Européen d'Archéométrie, with ion-beam-induced luminescence (IBIL) and other complementary techniques such as Raman, proton-induced X-ray emission (PIXE), and proton-induced gamma-ray emission (PIGE). IBIL, also known as ionoluminescence, has been used before to detect impurities or defects inside synthetic materials and natural minerals; its use for the discrimination of gemstone simulants or synthetic analogues has been elsewhere discussed (Cavenago-Bignami Moneta, Gemología, Tomo I Piedras preciosas, perlas, corales, marfil. Ediciones Omega, Barcelona, 1991). PIXE has been frequently applied in the archaeometric field for material characterisation and provenance studies of minerals (Hughes, Ruby & sapphire. RWH Publishing, Fallbrook, 1997; Calvo del Castillo et al., Anal Bioanal Chem 387:869-878, 2007; Calligaro et al., NIM-B 189:320-327, 2002) and PIGE complements the elemental analysis by detecting light elements in these materials such as-and lighter than-sodium that cannot be identified with the PIXE technique (Sanchez et al., NIM-B 130:682-686, 1997; Emmett et al., Gems Gemology 39:84-135, 2003). The micro-Raman technique has also been used complementarily to ion beam analysis techniques for mineral characterisation (Novak et al., Appl Surf Sci 231-232:917-920, 2004). The aim of this study is to provide new means for systematic analysis of corundum gemstone-quality mineral, alternative to the traditional gemmologic methods; for this purpose, a Spanish jewellery import company supplied us with a number of natural corundum samples coming from different places (part of them treated as explained above). The PIXE elemental concentrations of the samples showed large quantities of calcium and lead in some cases that can be linked to treatment with fluxes or lead oxide. The plot of the chromium and iron concentration grouped the samples in various aggregates that corresponded to the different types of corundum analysed. Micro-Raman complemented the PIXE analysis corroborating the presence of lead oxides but the use of the PIGE technique was not successful for the detection of beryllium due to the low cross section of the nuclear reaction chosen for its identification. IBIL was capable of distinguishing between treated and non-treated samples of the same type based on the luminescent features of the materials.
NASA Astrophysics Data System (ADS)
Verma, Shivcharan; Mohanty, Biraja P.; Singh, Karn P.; Kumar, Ashok
2018-02-01
The proton beam facility at variable energy cyclotron (VEC) Panjab University, Chandigarh, India is being used for Particle Induced X-ray Emission (PIXE) analysis of different environmental, biological and industrial samples. The PIXE method, however, does not provide any information of low Z elements like carbon, nitrogen, oxygen and fluorine. As a result of the increased need for rapid and multi-elemental analysis of biological and environmental samples, the PIXE facility was upgraded and standardized to facilitate simultaneous measurements using PIXE and Proton Elastic Scattering Analysis (PESA). Both PIXE and PESA techniques were calibrated and standardized individually. Finally, the set up was tested by carrying out simultaneous PIXE and PESA measurements using a 2 mm diameter proton beam of 2.7 MeV on few multilayered thin samples. The results obtained show excellent agreement between PIXE and PESA measurements and confirm adequate sensitivity and precision of the experimental set up.
Sun, Dequan; Hussain, Hashmath I; Yi, Zhifeng; Siegele, Rainer; Cresswell, Tom; Kong, Lingxue; Cahill, David M
2014-08-01
We report the uptake of MSNs into the roots and their movement to the aerial parts of four plant species and their quantification using fluorescence, TEM and proton-induced x - ray emission (micro - PIXE) elemental analysis. Monodispersed mesoporous silica nanoparticles (MSNs) of optimal size and configuration were synthesized for uptake by plant organs, tissues and cells. These monodispersed nanoparticles have a size of 20 nm with interconnected pores with an approximate diameter of 2.58 nm. There were no negative effects of MSNs on seed germination or when transported to different organs of the four plant species tested in this study. Most importantly, for the first time, a combination of confocal laser scanning microscopy, transmission electron microscopy and proton-induced X-ray emission (micro-PIXE) elemental analysis allowed the location and quantification MSNs in tissues and in cellular and sub-cellular locations. Our results show that MSNs penetrated into the roots via symplastic and apoplastic pathways and then via the conducting tissues of the xylem to the aerial parts of the plants including the stems and leaves. The translocation and widescale distribution of MSNs in plants will enable them to be used as a new delivery means for the transport of different sized biomolecules into plants.
Micro-PIXE analysis of silicate reference standards
Czamanske, G.K.; Sisson, T.W.; Campbell, J.L.; Teesdale, W.J.
1993-01-01
The accuracy and precision of the University of Guelph proton microprobe have been evaluated through trace-element analysis of well-characterized silicate glasses and minerals, including BHVO-1 glass, Kakanui augite and hornblende, and ten other natural samples of volcanic glass, amphibole, pyroxene, and garnet. Using the 2.39 wt% Mo in a NIST steel as the standard, excellent precision and agreement between reported and analyzed abundances were obtained for Fe, Ni, Cu, Zn, Ga, Rb, Sr, Y, Zr, and Nb. -from Authors
Carmona, Asuncion; Roudeau, Stéphane; L'Homel, Baptiste; Pouzoulet, Frédéric; Bonnet-Boissinot, Sarah; Prezado, Yolanda; Ortega, Richard
2017-04-15
Metallic nanoparticles have great potential in cancer radiotherapy as theranostic drugs since, they serve simultaneously as contrast agents for medical imaging and as radio-therapy sensitizers. As with other anticancer drugs, intratumoral diffusion is one of the main limiting factors for therapeutic efficiency. To date, a few reports have investigated the intratumoral distribution of metallic nanoparticles. The aim of this study was to determine the quantitative distribution of gadolinium (Gd) nanoparticles after direct intratumoral injection within U87 human glioblastoma tumors grafted in mice, using micro-PIXE (Particle Induced X-ray Emission) imaging. AGuIX (Activation and Guiding of Irradiation by X-ray) 3 nm particles composed of a polysiloxane network surrounded by gadolinium chelates were used. PIXE results indicate that the direct injection of Gd nanoparticles in tumors results in their heterogeneous diffusion, probably related to variations in tumor density. All tumor regions contain Gd, but with markedly different concentrations, with a more than 250-fold difference. Also Gd can diffuse to the healthy adjacent tissue. This study highlights the usefulness of mapping the distribution of metallic nanoparticles at the intratumoral level, and proposes PIXE as an imaging modality to probe the quantitative distribution of metallic nanoparticles in tumors from experimental animal models with micrometer resolution. Copyright © 2017 Elsevier Inc. All rights reserved.
Optimization of PIXE-sensitivity for detection of Ti in thin human skin sections
NASA Astrophysics Data System (ADS)
Pallon, Jan; Garmer, Mats; Auzelyte, Vaida; Elfman, Mikael; Kristiansson, Per; Malmqvist, Klas; Nilsson, Christer; Shariff, Asad; Wegdén, Marie
2005-04-01
Modern sunscreens contain particles like TiO2 having sizes of 25-70 nm and acting as a reflecting substance. For cosmetic reasons the particle size is minimized. Questions have been raised to what degree these nano particles penetrate the skin barrier, and how they do affect the human. The EU funded project "Quality of skin as a barrier to ultra-fine particles" - NANODERM has started with the purpose to evaluate the possible risks of TiO2 penetration into vital skin layers. The purpose of the work presented here was to find the optimal conditions for micro-PIXE analysis of Ti in thin skin sections. In the skin region where Ti is expected to be found, the naturally occurring major elements phosphorus, chlorine, sulphur and potassium have steep gradients and thus influence the X-ray background in a non-predictable manner. Based on experimental studies of Ti-exposed human skin sections using proton energies ranging from 1.8-2.55 MeV, the corresponding PIXE detection limits for Ti were calculated. The energy that was found to be the most favourable, 1.9 MeV, was then selected for future studies.
NASA Astrophysics Data System (ADS)
Okuyama, Katsushi; Komatsu, Hisanori; Yamamoto, Hiroko; Pereira, Patricia N. R.; Bedran-Russo, Ana K.; Nomachi, Masaharu; Sato, Takahiro; Sano, Hidehiko
2011-10-01
The use of fluoride for the prevention of caries is based on the transformation of hydroxylapatite to fluoroapatite in the presence of fluoride ions, thereby strengthening tooth structure. Adhesion of dentin and resin composite (tooth-colored restoration material) requires a dentin bonding system, since resin composite is not able to adhere to dentin directly. Demineralization of dentin by acid etching is an important step in the dentin bonding system, however, demineralization also introduces weaknesses in tooth structure. If the demineralized dentin could be strengthened by the application of fluoride, then the dentin-resin composite bond strength might also improve. To test this hypothesis, the present study evaluated the influence of fluoride applications on the strength of the dentin-resin composite bond by (1) tensile strength testing analyses, (2) SEM analyses of tooth structure, and (3) detection of calcium (Ca) and fluorine (F) distribution patterns by micro proton-induced X-ray emission (μ-PIXE) and micro proton-induced gamma-ray emission (μ-PIGE) analyses conducted at the Takasaki Ion Accelerators for Advanced Radiation Application (TIARA) at the Takasaki Advanced Radiation Research Institute (TARRI). In this study, the dentin in extracted human molars was exposed by grinding and the dentin was etched with 35% phosphoric acid. Fluoride was applied at two concentrations, 0.022% (100 ppm F) and 2.21% (10,000 ppm F) NaF solution, for two time periods, 30 and 60 s, prior to bonding the resin composite with the treated dentin. Controls were prepared in the same manner, but without the fluoride application. Bond strength was measured with a micro-tensile testing unit, and the fluorine and calcium distributions at the interface between dentin and resin composite were detected by μ-PIGE and μ-PIXE analysis, respectively. Results indicate that the 10,000 ppm F applications resulted in higher bond strengths than observed in either the 100 ppm F applications or the control group. In addition, PIGE analyses showed high concentrations of fluorine in the hybrid bonding layer of the 10,000 ppm F samples, suggesting that the fluorine contributes to the strength of the dentin-resin composite bond. Detection of fluoroapatite within the hybrid bonding layer suggests that bond strength involves remineralization processes.
Albéric, Marie; Müller, Katharina; Pichon, Laurent; Lemasson, Quentin; Moignard, Brice; Pacheco, Claire; Fontan, Elisabeth; Reiche, Ina
2015-05-01
Antique objects are known to have been brightly colored. However, the appearance of these objects has changed over time and paint traces are rarely preserved. The surface of ivory objects (8th century B.C., Syria) from the Louvre museum collection (Paris) have been non-invasively studied by simultaneous particle-induced X-ray emission (PIXE) and Rutherford and elastic backscattering spectrometry (RBS/EBS) micro-imaging at the AGLAE facility (C2RMF, Paris). Qualitative 2D chemical images of elements ranging from Na to Pb on the surface of the ancient ivory carvings provide evidence of lost polychromy and gilding. Quantitative PIXE data of specific areas allow discrimination between traces of sediments and former polychromy. Different shades of blue can be differentiated from particular Pb/Cu ratios. The characterization of gilding based on RBS data demonstrates the exceptional technological skills of the Phoenician craftsmen supposed to have carved the Arslan Tash ivories. More precise reconstructions of the original polychromy compared to previous studies and a criterion for the authentication of ancient gilded ivory object are proposed. Copyright © 2015 Elsevier B.V. All rights reserved.
Spatial investigation of some uranium minerals using nuclear microprobe
NASA Astrophysics Data System (ADS)
Valter, Anton A.; Knight, Kim B.; Eremenko, Gelij K.; Magilin, Dmitry V.; Ponomarov, Artem A.; Pisansky, Anatoly I.; Romanenko, Alexander V.; Ponomarev, Alexander G.
2018-01-01
In this work, several individual grains of uranium minerals—uraninite with high content of Ca, Ca-rich boltwoodite, growths of uranophane with β-uranophane, and weeksite—from different uranium deposits were studied by a scanning nuclear microprobe. Particle-induced X-ray emission technique provided by the microprobe (µ-PIXE) was carried out to obtain a concentration and 2D distribution of elements in these minerals. In addition, energy dispersive X-ray spectrometry (SEM-EDS) provided by a scanning electron microscope was used. The types of minerals were determined by X-ray diffraction methods. Results of this study improved the understanding of trace elemental composition of the uranium minerals depending on their origin. Obtained signatures could be linked then to the sample provenance. Such data are important for nuclear forensics to identify the ore types and even specific ore bodies, when only small samples may be available for analysis. In this study, the µ-PIXE technique was used for obtaining the 2D distribution of trace elements that are not commonly measured by SEM-EDS at the relevant concentrations. The detected levels and precisions of elements determination by µ-PIXE were also defined. Using µ-PIXE, several micro mineral inclusions such as phosphate with high level of V and Si were identified. The age of the uranium minerals was estimated due to a significant content of radiogenic Pb that provides an additional parameter for determination of the main attributive characteristics of the minerals. This work also showed that due to its high elemental sensitivity the nuclear microprobe can be a new analytical tool for creating a nuclear forensic database from the known uranium deposits and a subsequent analysis of the intercepted illicit materials.
Spatial investigation of some uranium minerals using nuclear microprobe
NASA Astrophysics Data System (ADS)
Valter, Anton A.; Knight, Kim B.; Eremenko, Gelij K.; Magilin, Dmitry V.; Ponomarov, Artem A.; Pisansky, Anatoly I.; Romanenko, Alexander V.; Ponomarev, Alexander G.
2018-06-01
In this work, several individual grains of uranium minerals—uraninite with high content of Ca, Ca-rich boltwoodite, growths of uranophane with β-uranophane, and weeksite—from different uranium deposits were studied by a scanning nuclear microprobe. Particle-induced X-ray emission technique provided by the microprobe (µ-PIXE) was carried out to obtain a concentration and 2D distribution of elements in these minerals. In addition, energy dispersive X-ray spectrometry (SEM-EDS) provided by a scanning electron microscope was used. The types of minerals were determined by X-ray diffraction methods. Results of this study improved the understanding of trace elemental composition of the uranium minerals depending on their origin. Obtained signatures could be linked then to the sample provenance. Such data are important for nuclear forensics to identify the ore types and even specific ore bodies, when only small samples may be available for analysis. In this study, the µ-PIXE technique was used for obtaining the 2D distribution of trace elements that are not commonly measured by SEM-EDS at the relevant concentrations. The detected levels and precisions of elements determination by µ-PIXE were also defined. Using µ-PIXE, several micro mineral inclusions such as phosphate with high level of V and Si were identified. The age of the uranium minerals was estimated due to a significant content of radiogenic Pb that provides an additional parameter for determination of the main attributive characteristics of the minerals. This work also showed that due to its high elemental sensitivity the nuclear microprobe can be a new analytical tool for creating a nuclear forensic database from the known uranium deposits and a subsequent analysis of the intercepted illicit materials.
NASA Astrophysics Data System (ADS)
Re, A.; Angelici, D.; Lo Giudice, A.; Maupas, E.; Giuntini, L.; Calusi, S.; Gelli, N.; Massi, M.; Borghi, A.; Gallo, L. M.; Pratesi, G.; Mandò, P. A.
2013-04-01
Lapis lazuli has been used for glyptics and carving since the fifth millennium BC to produce jewels, amulets, seals, inlays, etc; the identification of the origin of the stone used for carving artworks may be valuable for reconstructing old trade routes. Since ancient lapis lazuli art objects are precious, only non-destructive techniques can be used to identify their provenance, and ion beam analysis (IBA) techniques allow us to characterise this stone in a fully non-invasive way. In addition, by using an ion microprobe, we have been able to focus the analysis on single crystals, as their typical dimensions may range from a few microns to hundreds of microns. Provenance markers, identified in previous IBA studies and already presented elsewhere, were based on the presence/absence of mineral phases, on the presence/quantity of trace elements inside a phase and on characteristic features of the luminescence spectra. In this work, a systematic study on pyrite crystals, a common accessory mineral in lapis lazuli, was carried out, following a multi-technique approach: optical microscopy and SEM-EDX to select crystals for successive trace element micro-PIXE measurements at two Italian facilities, the INFN Laboratori Nazionali di Legnaro and the INFN LABEC laboratory in Firenze. The results of this work allowed us to obtain new markers for lapis lazuli provenance identification.
Yuan, Hua; Dragnea, Vladimira; Wu, Qiong; Gardner, Kevin H.; Bauer, Carl E.
2011-01-01
PixD (Slr1694) is a BLUF (blue-light using FAD) photoreceptor used by the cyanobacterium Synechocystis sp. PCC6803 to control phototaxis toward blue light. In this study we probe the involvement of a conserved Tyr8-Gln50-Met93 triad in promoting an output signal upon blue light excitation of the bound flavin. Analysis of acrylamide quenching of Trp91 fluorescence shows that the side chain of this residue remains partially solvent exposed in both the lit and dark states. Mutational analysis demonstrates that substitution mutations at Tyr8 and Gln50 result in the loss of the photocycle while a mutation of Met93 does not appreciably disturb the formation of the light excited state and only minimally accelerates its decay from 5.7 s to 4.5 s. However, mutations in Tyr8, Gln50 and Met93 disrupt the ability of PixD dimers to interact with PixE to form a higher ordered PixD10-PixE5 complex, which is indicative of a lit conformational state. Solution NMR spectroscopy and X-ray crystallographic analyses confirm that a Tyr8 to Phe mutation is locked in a pseudo light excited state revealing flexible areas in PixD that likely constitute part of an output signal upon light excitation of wild type PixD. PMID:21688827
Checking collagen preservation in archaeological bone by non-destructive studies (Micro-CT and IBA)
NASA Astrophysics Data System (ADS)
Beck, L.; Cuif, J.-P.; Pichon, L.; Vaubaillon, S.; Dambricourt Malassé, A.; Abel, R. L.
2012-02-01
The material to be studied is a piece of human skull discovered (1999) in Pleistocene sediments from the Orsang river (Gujarat state, India). From anatomical view point, this skull is highly composite: modern Homo sapiens characters are associated to undoubtedly more ancient features. Absolute dating by 14C is critical to understand this discovery. Prior to dating measurements, non-destructive studies have been carried out. Micro-CT reconstruction (X-ray microtomography) and Ion Beam Analysis (IBA) have been undertaken to check the structural preservation of the fossil and the collagen preservation. PIXE elemental map was used to select well-preserved bone area. RBS/EBS and NRA were used for light element quantification, in particular C, N and O contents. We also demonstrate that the PIXE-RBS/EBS combination is a effective tool for the whole characterization of archaeological and recent bones by analysing in one experiment both mineral and organic fractions. We have shown that the archaeological bone, a fragment of the potentially oldest modern Indian, is enough preserved for radiocarbon dating. We propose that Elastic Backscattering Spectrometry (EBS) using 3 MeV protons could be a good non destructive alternative to conventional CHN method using Carbon-Hydrogen-Nitrogen analyzer for measuring C and N before 14C dating.
NASA Astrophysics Data System (ADS)
Ishii, Keizo; Hatakeyama, Taisuke; Itoh, Shin; Sata, Daichi; Ohnuma, Tohru; Yamaguchi, Toshiro; Arai, Hiromu; Arai, Hirotsugu; Matsuyama, Shigeo; Terakawa, Atsuki; Kim, Seong-Yun
2016-03-01
We used X-ray computed tomography (CT) using characteristic X-rays produced in micro-particle-induced X-ray emission (PIXE) to investigate the internal structure of silt particles and develop new methods to decontaminate soil containing radioactive cesium. We obtained 3D attenuation coefficient images of silt particles with a diameter of approximately 100 μm for V K and Cr K X-rays. Owing to the absorption edges of the Cs L-shell, the differences between the V K and Cr K X-ray images revealed the spatial distribution of Cs atoms in the silt particles. Cs atoms were distributed over the surfaces of the silt particles to a thickness of approximately 10 μm. This information is useful for the decontamination of silt contaminated by radiation from the Fukushima Daiichi nuclear disaster.
Studies on bronze pre-monetary signs found in Dobroudja using XRF and micro-PIXE
NASA Astrophysics Data System (ADS)
Constantinescu, B.; Cristea-Stan, D.; Talmatchi, G.; Ceccato, D.
2016-03-01
We performed compositional analyses on 180 Scythian-type arrowheads and pre-monetary signs using XRF method and on 60 small fragments of such items (approx. 100 microns diameter), sampling being performed on previously corrosion-cleaned areas on their surface, using micro-PIXE. The items are found in Dobroudja, Istros-Histria region. The most relevant for numismatists result is that for each finding place the same type of alloy was used both for fighting arrowheads and for pre-monetary signs. Our analyses revealed three types of alloys: Cu-Sn-Pb ("normal" bronze), Cu-Sn-Mn-Pb and Cu-Sn-Sb-Pb. The presence of antimony suggests the use of fahlore-type poly-metals deposits, most probably from Caucasus Mountains. The problem of ancient bronze containing manganese is more complicated; an explanation could be the use of manganese oxides as flux necessary to smelt oxidized ores.
Investigation of strontium accumulation on ovariectomized Sprague-Dawley rat tibia by micro-PIXE
NASA Astrophysics Data System (ADS)
Li, X.; Li, Y.; Jin, W.; Zheng, Y.; Rong, C.; Lyu, H.; Shen, H.
2014-08-01
Strontium ranelate is a newly developed drug effective in osteoporosis treatment by depressing bone resorption and maintaining bone formation. Strontium accumulation and distribution are determined in bones of rat after strontium ranelate administration by using micro-PIXE. The investigated rats are divided into four groups: (A) control, (B) ovariectomized, (C) ovariectomized followed with strontium chloride, (D) ovariectomized followed with strontium ranelate. It was found that strontium ranelate would result in increasing trabecular volume and decreasing bone resorption to treat osteoporosis. There are similar contours of calcium and strontium in two-dimensional images, while the strontium is not evenly distributed in the bone. It supports the conclusion that strontium has an affinity for bone and it is capable of replacing calcium atoms as a part of the strontium mechanism in the osteoporosis treatment. The results related to biochemistry are also discussed.
NASA Astrophysics Data System (ADS)
Natyanun, S.; Unai, S.; Yu, L. D.; Tippawan, U.; Pussadee, N.
2017-09-01
This study was aimed at understanding elemental concentration distribution in local longan leaf for how the plant was affected by the environment or agricultural operation. The analysis applied the MeV-microbeam particle induced X-ray emission (PIXE) mapping technique using a home-developed tapered glass capillary microbeam system at Chiang Mai University. The microbeam was 2-MeV proton beam in 130 µm in diameter. The studying interest was in the difference in the elemental concentrations distributed between the leaf midrib and lamina areas. The micro proton beam analyzed the leaf sample across the leaf midrib edge to the leaf lamina area for total 9 data requisition spots. The resulting data were colored to form a 1D-map of the elemental concentration distribution. Seven dominant elements, Al, S, Cl, K, Ca, Sc and Fe, were identified, the first six of which were found having higher concentrations in the midrib area than in the lamina area, while the Fe concentration was in an opposite trend to that of the others.
NASA Astrophysics Data System (ADS)
Gomez-Morilla, Inmaculada; Thoree, Vinay; Powell, Jonathan J.; Kirkby, Karen J.; Grime, Geoffrey W.
2006-08-01
Microscopic particles (0.5-2 μm diameter), rich in calcium and phosphorus, are found in the lumen of the mid-distal gut of all mammals investigated, including humans, and these may play a role in immuno-surveillance and immune regulation of antigens from food and symbiotic bacteria that are contained in the gut. Whether these particles can cross in to tissue of the intestinal mucosa is unclear. If so, characterising their morphology and chemical composition is an important task in elucidating their function. The analysis of calcium phosphate in biological tissues has been approached in several ways including optical microscopy, scanning electron microscopy and, most recently in this work, with nuclear microscopy. In this paper, we describe the use of microPIXE and microRBS to locate these particles and to determine, accurately, the ratio of phosphorus to calcium using the information on sample thickness obtained from RBS to allow the PIXE ratios to be corrected. A commercial sample of hydroxy apatite was used to demonstrate accuracy and precision of the technique. Then, in a pilot study on intestinal tissue of mice, we demonstrated the presence of calcium phosphate microparticles, consistent with confocal microscopy observations, and we identified the average molar P:Ca molar ratio as 1.0. Further work will confirm the exact chemical speciation of these particles and will examine the influence of differing calcium containing diets on the formation of these microparticles.
PIXE and /μ-PIXE analysis of glazes from terracotta sculptures of the della Robbia workshop
NASA Astrophysics Data System (ADS)
Zucchiatti, Alessandro; Bouquillon, Anne; Giancarlo Lanterna; Lucarelli, Franco; Mandò, Pier Andrea; Prati, Paolo; Salomon, Joseph; Vaccari, Maria Grazia
2002-04-01
A series of PIXE analyses has been performed on glazes from terracotta sculptures of the Italian Renaissance and on reference standards. The problems related to the investigation of such heterogeneous materials are discussed and the experimental uncertainties are evaluated, for each element, from the PIXE analysis of standard glasses. Some examples from artefacts coming from Italian collections are given. This research has been conducted in the framework of the COST-G1 European action.
Combined PIXE and XPS analysis on republican and imperial Roman coins
NASA Astrophysics Data System (ADS)
Daccà, A.; Prati, P.; Zucchiatti, A.; Lucarelli, F.; Mandò, P. A.; Gemme, G.; Parodi, R.; Pera, R.
2000-03-01
A combined PIXE and XPS analysis has been performed on a few Roman coins of the republican and imperial age. The purpose was to investigate via XPS the nature and extent of patina in order to be capable of extracting PIXE data relative to the coins bulk. The inclusion of elements from the surface layer, altered by oxidation and inclusion, is a known source of uncertainty in PIXE analyses of coins, performed to assess the composition and the provenance.
NASA Astrophysics Data System (ADS)
Yin, Zhongli; Zhang, Shunun; Jiang, Xinzhou; Ma, Changjun; Li, Zhenkun; Hao, Jifang; Zheng, Zhihao; Liu, Zhaoyuan; Liu, Zhengmin; Ma, Shuxun; Yang, Kunshan
1989-04-01
This paper describes briefly the optimization of a PIXE setup. Three proton energies 1.5, 2.0 and 2.5 MeV and four kinds of absorbers BE (132 μm), Be (460 μm), Al (28 μm) and Be plus Mylar (460 μm+600 μm) were used. The minimum detection limits (MDL) of PIXE for these various combinations were computed and compared. PIXE analysis of Shaji was performed as an application. The result shows that the stack absorber of 460 μm Be and 600 μm Mylar films and a 2.0 MeV proton energy are most suitable for PIXE analysis of Shaji. Results of the Shaji analysis are presented. Shaji is one of the common seabuckthoms. The Shaji referred to here belongs to Hippophae rhamnoides L. Subsp. Sinensis Rousi.
Theoretical detection limit of PIXE analysis using 20 MeV proton beams
NASA Astrophysics Data System (ADS)
Ishii, Keizo; Hitomi, Keitaro
2018-02-01
Particle-induced X-ray emission (PIXE) analysis is usually performed using proton beams with energies in the range 2∼3 MeV because at these energies, the detection limit is low. The detection limit of PIXE analysis depends on the X-ray production cross-section, the continuous background of the PIXE spectrum and the experimental parameters such as the beam currents and the solid angle and detector efficiency of X-ray detector. Though the continuous background increases as the projectile energy increases, the cross-section of the X-ray increases as well. Therefore, the detection limit of high energy proton PIXE is not expected to increase significantly. We calculated the cross sections of continuous X-rays produced in several bremsstrahlung processes and estimated the detection limit of a 20 MeV proton PIXE analysis by modelling the Compton tail of the γ-rays produced in the nuclear reactions, and the escape effect on the secondary electron bremsstrahlung. We found that the Compton tail does not affect the detection limit when a thin X-ray detector is used, but the secondary electron bremsstrahlung escape effect does have an impact. We also confirmed that the detection limit of the PIXE analysis, when used with 4 μm polyethylene backing film and an integrated beam current of 1 μC, is 0.4∼2.0 ppm for proton energies in the range 10∼30 MeV and elements with Z = 16-90. This result demonstrates the usefulness of several 10 MeV cyclotrons for performing PIXE analysis. Cyclotrons with these properties are currently installed in positron emission tomography (PET) centers.
Micro-PIXE studies of elemental distribution in Cd-accumulating Brassica juncea L.
NASA Astrophysics Data System (ADS)
Schneider, Thorsten; Haag-Kerwer, Angela; Maetz, Mischa; Niecke, Manfred; Povh, Bogdan; Rausch, Thomas; Schüßler, Arthur
1999-10-01
Brassica juncea L. is a high biomass producing crop plant, being able to accumulate Cd and other heavy metals in their roots and shoots. It is a good candidate for efficient phytoextraction of heavy metals - such as Cd - from polluted soils. PIXE and STIM analyses were applied to investigate Cd-uptake in roots and the resulting effects on the elemental distribution of Cd stressed plants. The axial distribution of trace elements as a function of distance from the root tip as well as the radial distribution within cross-sections were analysed. The results are compared with the elemental distribution in control plants.
Microbeam complex at TIARA: Technologies to meet a wide range of applications
NASA Astrophysics Data System (ADS)
Kamiya, T.; Takano, K.; Satoh, T.; Ishii, Y.; Nishikawa, H.; Seki, S.; Sugimoto, M.; Okumura, S.; Fukuda, M.
2011-10-01
Since 1990 R&Ds of microbeam technology has been progressed at the TIARA facility of JAEA Takasaki. In order to meet a wide variety of ion beam applications, analysis, radiation effect studies, or fabrication in regions of micro- or nano-structures, three different types of ion microbeam systems were developed. In these systems, high-spatial resolutions have been achieved and techniques of micro-PIXE, single ion hit and particle beam writing (PBW) were also developed for these applications. Microbeams, on the other hand, require the highest quality of beams from the accelerators, the cyclotron in particular, which was an important part of the microbeam technology of TIARA. In this paper, the latest progress of the ion microbeam technology and applications are summarized and a future prospect of them is discussed.
Fixation and chemical analysis of single fog and rain droplets
NASA Astrophysics Data System (ADS)
Kasahara, M.; Akashi, S.; Ma, C.-J.; Tohno, S.
Last decade, the importance of global environmental problems has been recognized worldwide. Acid rain is one of the most important global environmental problems as well as the global warming. The grasp of physical and chemical properties of fog and rain droplets is essential to make clear the physical and chemical processes of acid rain and also their effects on forests, materials and ecosystems. We examined the physical and chemical properties of single fog and raindrops by applying fixation technique. The sampling method and treatment procedure to fix the liquid droplets as a solid particle were investigated. Small liquid particles like fog droplet could be easily fixed within few minutes by exposure to cyanoacrylate vapor. The large liquid particles like raindrops were also fixed successively, but some of them were not perfect. Freezing method was applied to fix the large raindrops. Frozen liquid particles existed stably by exposure to cyanoacrylate vapor after freezing. The particle size measurement and the elemental analysis of the fixed particle were performed in individual base using microscope, and SEX-EDX, particle-induced X-ray emission (PIXE) and micro-PIXE analyses, respectively. The concentration in raindrops was dependent upon the droplet size and the elapsed time from the beginning of rainfall.
NASA Astrophysics Data System (ADS)
Nilsson, E. J. C.; Pallon, J.; Przybylowicz, W. J.; Wang, Y. D.; Jönsson, K. I.
2014-08-01
Although heavy on labor and equipment, thus not often applied, cryoanalysis of frozen hydrated biological specimens can provide information that better reflects the living state of the organism, compared with analysis in the freeze-dried state. In this paper we report a study where the cryoanalysis facility with cryosectioning capabilities at Materials Research Department, iThemba LABS, South Africa was employed to evaluate the usefulness of combining three ion beam analytical methods (μPIXE, RBS and STIM) to analyze a biological target where a better elemental compositional description is needed - the tardigrade. Imaging as well as quantification results are of interest. In a previous study, the element composition and redistribution of elements in the desiccated and active states of two tardigrade species was investigated. This study included analysis of both whole and sectioned tardigrades, and the aim was to analyze each specimen twice; first frozen hydrated and later freeze-dried. The combination of the three analytical techniques proved useful: elements from C to Rb in the tardigrades could be determined and certain differences in distribution of elements between the frozen hydrated and the freeze-dried states were observed. RBS on frozen hydrated specimens provided knowledge of matrix elements.
Chemical speciation using high energy resolution PIXE spectroscopy in the tender X-ray range
NASA Astrophysics Data System (ADS)
Kavčič, Matjaž; Petric, Marko; Vogel-Mikuš, Katarina
2018-02-01
High energy resolution X-ray emission spectroscopy employing wavelength dispersive (WDS) crystal spectrometers can provide energy resolution on the level of core-hole lifetime broadening of the characteristic emission lines. While crystal spectrometers have been traditionally used in combination with electron excitation for major and minor element analysis, they have been rarely considered in proton induced X-ray emission (PIXE) trace element analysis mainly due to low detection efficiency. Compared to the simplest flat crystal WDS spectrometer the efficiency can be improved by employing cylindrically or even spherically curved crystals in combination with position sensitive X-ray detectors. When such spectrometer is coupled to MeV proton excitation, chemical bonding effects are revealed in the high energy resolution spectra yielding opportunity to extend the analytical capabilities of PIXE technique also towards chemical state analysis. In this contribution we will focus on the high energy resolution PIXE (HR-PIXE) spectroscopy in the tender X-ray range performed in our laboratory with our home-built tender X-ray emission spectrometer. Some general properties of high energy resolution PIXE spectroscopy in the tender X-ray range are presented followed by an example of sulfur speciation in biological tissue illustrating the capabilities as well as limitations of HR-PIXE method used for chemical speciation in the tender X-ray range.
Forensic practice in the field of protection of cultural heritage
NASA Astrophysics Data System (ADS)
Kotrlý, Marek; Turková, Ivana
2012-06-01
Microscopic methods play a key role in issues covering analyses of objects of art that are used on the one hand as screening ones, on the other hand they can lead to obtaining data relevant for completion of expertise. Analyses of artworks, gemmological objects and other highly valuable commodities usually do not rank among routine ones, but every analysis is specific, be it e.g. material investigation of artworks, historical textile materials and other antiques (coins, etc.), identification of fragments (from transporters, storage places, etc.), period statues, sculptures compared to originals, analyses of gems and jewellery, etc. A number of analytical techniques may be employed: optical microscopy in transmitted and reflected light, polarization and fluorescence in visible, UV and IR radiation; image analysis, quantitative microspectrophotometry; SEM/EDS/WDS; FTIR and Raman spectroscopy; XRF and microXRF, including mobile one; XRD and microXRD; x-ray backlight or LA-ICP-MS, SIMS, PIXE; further methods of organic analysis are also utilised - GS-MS, MALDI-TOF, etc.
NASA Astrophysics Data System (ADS)
Massi, M.; Calusi, S.; Giuntini, L.; Ruggieri, G.; Dini, A.
2008-05-01
Fluid inclusions are small portions, usually smaller than 100 μm, of fluid trapped within minerals during or after growth. Their characteristics provide therefore fundamental information on nature and evolution of fluids present in the past in different geological environments. At the LABEC laboratory in Firenze, high-salinity fluid inclusions in quartz crystals, coming from the Apuan Alps metamorphic complex, were analysed at the external scanning microbeam. Results, although still preliminary, have already provided us with hints on fluid-rock interaction processes during the metamorphism of the Apuan Alps.
PIXE analysis of caries related trace elements in tooth enamel
NASA Astrophysics Data System (ADS)
Annegarn, H. J.; Jodaikin, A.; Cleaton-Jones, P. E.; Sellschop, J. P. F.; Madiba, C. C. P.; Bibby, D.
1981-03-01
PIXE analysis has been applied to a set of twenty human teeth to determine trace element concentration in enamel from areas susceptible to dental caries (mesial and distal contact points) and in areas less susceptible to the disease (buccal surfaces), with the aim of determining the possible roles of trace elements in the curious process. The samples were caries-free anterior incisors extracted for periodontal reasons from subjects 10-30 years of age. Prior to extraction of the sample teeth, a detailed dental history and examination was carried out in each individual. PIXE analysis, using a 3 MeV proton beam of 1 mm diameter, allowed the determination of Ca, Mn, Fe, Cu, Zn, Sr and Pb above detection limits. As demonstrated in this work, the enhanced sensitivity of PIXE analysis over electron microprobe analysis, and the capability of localised surface analysis compared with the pooled samples required for neutron activation analysis, makes it a powerful and useful technique in dental analysis.
Ghorbanzadeh Mashkani, Saeid; Tajer Mohammad Ghazvini, Parisa
2009-03-01
The presence of Cs and Sr in culture medium of Azolla filiculoides caused about 27.4% and 46.3% inhibition of biomass growth, respectively, in comparison to A. filiculoides control weight which had not metals. Biosorption batch experiments were conducted to determine the Cs and Sr binding ability of native biomass and chemically modified biosorbents derived from Azolla namely ferrocyanide Azolla sorbents type 1 and type 2 (FAS1 and FAS2) and hydrogen peroxide Azolla sorbent (HAS). The best Cs and Sr removal results were obtained when A. filiculoides was treated by 2M MgCl(2) and 30ml H(2)O(2) 8mM at pH 7 for 12h and it was then washed by NaOH solution at pH 10.5 for 6h. Pretreatment of Azolla have been suggested to modify the surface characteristics which could improve biosorption process. The binding of Cs and Sr on the cell wall of Azolla was studied with micro-PIXE and FT-IR.
On the Applications of IBA Techniques to Biological Samples Analysis: PIXE and RBS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Falcon-Gonzalez, J. M.; Bernal-Alvarado, J.; Sosa, M.
2008-08-11
The analytical techniques based on ion beams or IBA techniques give quantitative information on elemental concentration in samples of a wide variety of nature. In this work, we focus on PIXE technique, analyzing thick target biological specimens (TTPIXE), using 3 MeV protons produced by an electrostatic accelerator. A nuclear microprobe was used performing PIXE and RBS simultaneously, in order to solve the uncertainties produced in the absolute PIXE quantifying. The advantages of using both techniques and a nuclear microprobe are discussed. Quantitative results are shown to illustrate the multielemental resolution of the PIXE technique; for this, a blood standard wasmore » used.« less
A new ion beam facility based on a 3 MV Tandetron™ at IFIN-HH, Romania
NASA Astrophysics Data System (ADS)
Burducea, I.; Straticiuc, M.; Ghiță, D. G.; Moșu, D. V.; Călinescu, C. I.; Podaru, N. C.; Mous, D. J. W.; Ursu, I.; Zamfir, N. V.
2015-09-01
A 3 MV Tandetron™ accelerator system has been installed and commissioned at the "Horia Hulubei" National Institute for Physics and Nuclear Engineering - IFIN-HH, Măgurele, Romania. The main purpose of this machine is to strengthen applied nuclear physics research ongoing in our institute for more than four decades. The accelerator system was developed by High Voltage Engineering Europa B.V. (HVE) and comprises three high energy beam lines. The first beam line is dedicated to ion beam analysis (IBA) techniques: Rutherford Backscattering Spectrometry - RBS, Nuclear Reaction Analysis - NRA, Particle Induced X-ray and γ-ray Emission - PIXE and PIGE and micro-beam experiments - μ-PIXE. The second beam line is dedicated to high energy ion implantation experiments and the third beam line was designed mainly for nuclear cross-sections measurements used in nuclear astrophysics. A unique feature, the first time in operation at an accelerator facility is the Na charge exchange canal (CEC), which is used to obtain high intensity beams of He- of at least 3 μA. The results of the acceptance tests demonstrate the huge potential of this new facility in various fields, from IBA to radiation hardness studies and from medical or environmental applications to astrophysics. The main features of the accelerator are presented in this paper.
PIXE study on the provenance of Chinese ancient porcelain
NASA Astrophysics Data System (ADS)
Zhu, D.; Cheng, H. S.; Lin, J. W.; Yang, F. J.
2006-08-01
This paper reports the PIXE study on the provenance of Chinese ancient porcelain made in 7-10th century. The chemical compositions of Jun celadon samples made at Juntai, Linru and Hunyuan kilns, the white-glazed porcelain samples made at Ding, Huangye and Dangyangyu kilns, and the Ru celadon samples made at Qiangliang Temple were measured by external-beam PIXE, and the factor analysis was applied for identifying their provenances. Experimental results show that the porcelain products made at different kilns can be distinguished according to the compositional differences measured by PIXE.
NASA Astrophysics Data System (ADS)
Randle, K.; Al-Jundi, J.; Mamas, C. J. V.; Sokhi, R. S.; Earwaker, L. G.
1993-06-01
Our work on heavy metals in the estuarine environment has involved the use of two multielement techniques: neutron activation analysis (NAA) and proton-induced X-ray emission (PIXE) analysis. As PIXE is essentially a surface analytical technique problems may arise due to sample inhomogeneity and surface roughness. In order to assess the contribution of these effects we have compared the results from PIXE analysis with those from a technique which analyzes a larger bulk sample rather than just the surface. An obvious method was NAA. A series of sediment samples containing particles of variable diameter were compared. Pellets containing a few mg of sediment were prepared from each sample and analyzed by the PIXE technique using both an absolute and a comparitive method. For INAA the rest of the sample was then irradiated with thermal neutrons and element concentrations determined from analyses of the subsequent gamma-ray spectrum. Results from the two methods are discussed.
PIXE analysis of elements in gastric cancer and adjacent mucosa
NASA Astrophysics Data System (ADS)
Liu, Qixin; Zhong, Ming; Zhang, Xiaofeng; Yan, Lingnuo; Xu, Yongling; Ye, Simao
1990-04-01
The elemental regional distributions in 20 resected human stomach tissues were obtained using PIXE analysis. The samples were pathologically divided into four types: normal, adjacent mucosa A, adjacent mucosa B and cancer. The targets for PIXE analysis were prepared by wet digestion with a pressure bomb system. P, K, Fe, Cu, Zn and Se were measured and statistically analysed. We found significantly higher concentrations of P, K, Cu, Zn and a higher ratio of Cu compared to Zn in cancer tissue as compared with normal tissue, but statistically no significant difference between adjacent mucosa and cancer tissue was found.
Pix proteins and the evolution of centrioles.
Woodland, Hugh R; Fry, Andrew M
2008-01-01
We have made a wide phylogenetic survey of Pix proteins, which are constituents of vertebrate centrioles in most eukaryotes. We have also surveyed the presence and structure of flagella or cilia and centrioles in these organisms, as far as is possible from published information. We find that Pix proteins are present in a vast range of eukaryotes, but not all. Where centrioles are absent so are Pix proteins. If one considers the maintenance of Pix proteins over evolutionary time scales, our analysis would suggest that their key function is to make cilia and flagella, and the same is true of centrioles. Moreover, this survey raises the possibility that Pix proteins are only maintained to make cilia and flagella that undulate, and even then only when they are constructed by transporting ciliary constituents up the cilium using the intraflagellar transport (IFT) system. We also find that Pix proteins have become generally divergent within Ecdysozoa and between this group and other taxa. This correlates with a simplification of centrioles within Ecdysozoa and a loss or divergence of cilia/flagella. Thus Pix proteins act as a weathervane to indicate changes in centriole function, whose core activity is to make cilia and flagella.
PIXE as a complement to ICP-OES trace metal analysis in Sudanese medicinal plants.
Mubark Ebrahim, Ammar; Etayeb, M A; Khalid, H; Noun, Manale; Roumie, M; Michalke, B
2014-08-01
This paper compares trace element concentrations (Ca, K, Sr, Fe, Mn, Zn, Ni, Cu, Co and Cr) in 27 Sudanese medical plants determined in parallel by PIXE and ICP-OES to get information on which technique is preferable at different matrices and element concentrations. PIXE correlates well to ICP-OES for Sr, Mn, Ca, K, Zn and Fe determinations. ICP-OES seems to be the superior technique over PIXE when measuring low concentrated elements (chromium, cobalt, nickel and copper) in the medicinal plants. Copyright © 2014 Elsevier Ltd. All rights reserved.
Large scale intercomparison of aerosol trace element analysis by different analytical methods
NASA Astrophysics Data System (ADS)
Bombelka, E.; Richter, F.-W.; Ries, H.; Wätjen, U.
1984-04-01
The general agreement of PIXE analysis with other methods (INAA, XRF, AAS, OES-ICP, and PhAA) is very good based on the analysis of filter pieces taken from 250 aerosol samples. It is better than 5% for Pb and Zn, better than 10% for V, Cr, and Mn, indicating that the accuracy of PIXE analysis can be within 10%. For elements such as Cd and Sb, difficult to analyze by PIXE because of their low mass content in the sample, the agreement is given mainly by the reproducibility of the method (20% to 30%). Similar agreement is found for sulfur, after taking account of the depth distribution of the aerosol in the filter.
PIXE analysis of cystic fibrosis sweat samples with an external proton beam
NASA Astrophysics Data System (ADS)
Sommer, F.; Massonnet, B.
1987-03-01
PIXE analysis with an external proton beam is used to study, in four control and five cystic fibrosis children, the elemental composition of sweat samples collected from different parts of the body during entire body hyperthermia. We observe no significant difference of sweat rates and of temperature variations between the two groups during sweat test. The statistical study of results obtained by PIXE analysis allows us to pick out amongst 8 elements studied, 6 elements (Na, Cl, Ca, Mn, Cu, Br) significatively different between the two groups of subjects. Using regression analysis, Na, Cl and Br concentrations could be used in a predictive equation of the state of health.
NASA Astrophysics Data System (ADS)
Weiersbye-Witkowski, I. M.; Przybylowicz, W. J.; Straker, C. J.; Mesjasz-Przybylowicz, J.
1997-07-01
Genotypes of the Southern African cucurbit, Lagenaria sphaerica, that are resistant to powdery-mildew ( Sphaerotheca fuliginea) exhibit foliar hypersensitive (HS) lesions on inoculation with this fungal pathogen. Elemental distributions across radially symmetrical HS lesions, surrounding unlesioned leaf tissue and uninoculated leaf tissue, were obtained using the true elemental imaging system (Dynamic Analysis) of the NAC Van de Graaff nuclear microprobe. Raster scans of 3 MeV protons were complemented by simultaneous PIXE and BS point analyses. The composition of cellulose (C 6H 10O 5) was used as constant matrix composition for scans, and the sample thickness was found from BS spectra. Si and elements heavier than Ca contributed to matrix composition within HS lesions and the locally elevated Ca raised the limits of detection for some trace metals of interest. In comparison to uninoculated tissue, inoculated tissue was characterised by higher overall concentrations of all measured elements except Cu. Fully developed, 6 day-old HS lesions and the surrounding tissue could be divided into five zones, centred on the fungal infection site. Each zone was characterized by distinct local elemental distributions (either depletion, or accumulation to potentially phytotoxic levels).
The hoard of Beçin—non-destructive analysis of the silver coins
NASA Astrophysics Data System (ADS)
Rodrigues, M.; Schreiner, M.; Mäder, M.; Melcher, M.; Guerra, M.; Salomon, J.; Radtke, M.; Alram, M.; Schindel, N.
2010-05-01
We report the results of an analytical investigation on 416 silver-copper coins stemming from the Ottoman Empire (end of 16th and beginning of 17th centuries), using synchrotron micro X-ray fluorescence analysis (SRXRF). In the past, analyses had already been conducted with energy dispersive X-ray fluorescence analysis (EDXRF), scanning electron microscopy with energy dispersive X-ray spectrometry (SEM/EDX) and proton induced X-ray emission spectroscopy (PIXE). With this combination of techniques it was possible to confirm the fineness of the coinage as well as to study the provenance of the alloy used for the coins. For the interpretation of the data statistical analysis (principal component analysis—PCA) has been performed. A definite local assignment was explored and significant clustering was obtained regarding the minor and trace elements composing the coin alloys.
THE MULTIELEMENTAL ANALYSIS OF DRINKING WATER USING PROTON-INDUCED X-RAY EMISSION (PIXE)
A new, rapid, and economical method for the multielemental analysis of drinking water samples is described. The concentrations of 76 elements heavier than aluminum are determined using proton-induced x-ray emission (PIXE) technology. The concentration of sodium is evaluated using...
NASA Astrophysics Data System (ADS)
Koosaletse-Mswela, Pulane; Przybyłowicz, Wojciech J.; Cloete, Karen J.; Barnabas, Alban D.; Torto, Nelson; Mesjasz-Przybyłowicz, Jolanta
2015-11-01
Multi-element profiling is essential in understanding the metal-tolerant behavior of metallophytes. Although previous reports using multi-elemental analyses show that the metallophytes Blepharis aspera, Blepharis diversispina (Acanthaceae) and Helichrysum candolleanum (Asteraceae) take up metals, no information exists on elemental spatial distribution and concentrations in specific tissues of these plants. The aim of this study therefore was to assess the spatial distribution and concentration of copper, nickel and other elements in leaf tissues of these plants using micro-PIXE. Whole plants were collected with soil in pots from an operational copper and nickel mine (i.e., a copper and nickel mineralized area), Selkirk, about 40 km north-east of Francistown, Botswana. On the same day the samples were transported by air to iThemba LABS in South Africa. Leaf specimens were cryofixed in liquid propane cooled by LN2. Parallel samples were embedded in resin for anatomical studies to facilitate interpretation of elemental maps. The distribution and concentration of copper, nickel, and other elements in leaf tissues were determined using micro-PIXE and proton backscattering spectrometry. Data evaluation was performed using GeoPIXE II software. Micro-PIXE showed that H. candolleanum had the highest whole leaf content of copper (70 ± 3 μg g-1 DW) and nickel (168 ± 5 μg g-1 DW), followed by B. aspera (Cu: 25 ± 1 μg g-1 DW; Ni: 166 ± 4 μg g-1 DW) and B. diversispina (Cu: 3 ± 1 μg g-1 DW; Ni, below detection limit). For specific leaf tissues, the highest levels of copper were found in the vascular bundle for H. candolleanum (167 ± 7 μg g-1 DW) and the lower epidermis for B. aspera (70 ± 9 μg g-1 DW). The highest levels of nickel were present in the vascular bundle of B. aspera (479 ± 10 μg g-1 DW) and H. candolleanum (90 ± 5 μg g-1 DW). Elemental maps showed a similar distribution pattern for copper and nickel in B. aspera and B diversispina, with these elements concentrated in the upper and lower epidermal regions. However, for H. candolleanum, both copper and nickel were concentrated in the mesophyll. The difference in concentration and accumulation patterns between B. aspera, B. diversispina and H. candolleanum suggests that the metal-tolerant adaptation of these metallophytes may differ.
Nuclear micro-probe analysis of Arabidopsis thaliana leaves
NASA Astrophysics Data System (ADS)
Ager, F. J.; Ynsa, M. D.; Domínguez-Solís, J. R.; López-Martín, M. C.; Gotor, C.; Romero, L. C.
2003-09-01
Phytoremediation is a cost-effective plant-based approach for remediation of soils and waters which takes advantage of the remarkable ability of some plants to concentrate elements and compounds from the environment and to metabolize various molecules in their tissues, such as toxic heavy metals and organic pollutants. Nowadays, phytoremediation technology is becoming of paramount importance when environmental decontamination is concerned, due to the emerging knowledge of its physiological and molecular mechanisms and the new biological and engineering strategies designed to optimize and improve it. In addition, the feasibility of using plants for environmental cleanup has been confirmed by many different trials around the world. Arabidopsis thaliana plants can be used for basic studies to improve the technology on phytoremediation. Making use of nuclear microscopy techniques, in this paper we study leaves of wild type and transgenic A. thaliana plants grown in a cadmium-rich environment under different conditions. Micro-PIXE, RBS and SEM analyses, performed on the scanning proton micro-probe at the CNA in Seville (Spain), prove that cadmium is preferentially sequestered in the central region of epidermal trichome and allow comparing the effects of genetic modifications.
PIXE analysis of historical paintings: Is the gain worth the risk?
NASA Astrophysics Data System (ADS)
Calligaro, T.; Gonzalez, V.; Pichon, L.
2015-11-01
The PIXE analysis of easel paintings constitutes a challenging task. Despite recognized merits and a few emblematic applications, PIXE has never been routinely applied to these fragile, complex and precious targets. The present work discusses the place of PIXE in the study of easel paintings and opens up perspectives for a more systematic usage of this analytical technique. Progress achieved since decades in the implementation of PIXE to study such fragile cultural heritage artefacts is reviewed, notably at the LABEC laboratory in Italy and at the AGLAE facility of the C2RMF in France. Two specific techniques developed for paintings are detailed and exemplified on Renaissance painting masterpieces: differential PIXE for paint layers depth profiling and multi-scale elemental mapping for the imaging of pigment distribution. Beam-induced damage, a major concern, notably depends on the employed beam fluence in particle/cm2 or μC/cm2. After recalling previous works on damage induced in chemical products comparable to pigments, we present the behaviour under different fluences of protons of a few MeV (1-300 μC/cm2) of targets having high resemblance to historical easel paintings: pellets of specially synthesized lead white pigments, layers of lead white mixed with linseed oil and areas containing lead white of two 19th century paintworks. The results shed new lights on the behaviour of paintworks under the beam and pave the way to strategies for damage mitigation. In particular, the lowering of PIXE performance induced by the decrease of the beam fluence sets a trade-off between risk of damage and gained information which also impacts the PIXE scanning protocol for paintings. As an illustration of an adequate adjustment of this balance, we report the exploratory application of PIXE mapping to a large area of a 19th century easel painting without damage. The recorded elemental maps are compared to elemental maps collected on the same area using laboratory-based scanning XRF.
Detection of halogenated flame retardants in polyurethane foam by particle induced X-ray emission
NASA Astrophysics Data System (ADS)
Maley, Adam M.; Falk, Kyle A.; Hoover, Luke; Earlywine, Elly B.; Seymour, Michael D.; DeYoung, Paul A.; Blum, Arlene; Stapleton, Heather M.; Peaslee, Graham F.
2015-09-01
A novel application of particle-induced X-ray emission (PIXE) has been developed to detect the presence of chlorinated and brominated flame retardant chemicals in polyurethane foams. Traditional Gas Chromatography-Mass Spectrometry (GC-MS) methods for the detection and identification of halogenated flame retardants in foams require extensive sample preparation and data acquisition time. The elemental analysis of the halogens in polyurethane foam performed by PIXE offers the opportunity to identify the presence of halogenated flame retardants in a fraction of the time and sample preparation cost. Through comparative GC-MS and PIXE analysis of 215 foam samples, excellent agreement between the two methods was obtained. These results suggest that PIXE could be an ideal rapid screening method for the presence of chlorinated and brominated flame retardants in polyurethane foams.
NASA Astrophysics Data System (ADS)
Stedman, J. D.; Spyrou, N. M.
1994-12-01
The trace element concentrations in porcine brain samples as determined by particle-induced X-ray emission (PIXE) analysis, instrumental neutron activation analysis (INAA) and particle-induced gamma-ray emission (PIGE) analysis are compared. The matrix composition was determined by Rutherford backscattering (RBS). Al, Si, P, S, Cl, K, Ca, Mn, Fe and Cd were determined by PIXE analysis Na, K, Sc, Fe, Co, Zn, As, Br, Rb, and Cs by INAA and Na, Mg and Fe by PIGE analysis. The bulk elements C, N, O, Na Cl and S were found by RBS analysis. Elemental concentrations are obtained using the comparator method of analysis rather than an absolute method, the validity which is examined by comparing the elemental concentrations obtained in porcine brain using two separate certified reference materials.
Non-destructive analysis and appraisal of ancient Chinese porcelain by PIXE
NASA Astrophysics Data System (ADS)
Cheng, H. S.; Zhang, Z. Q.; Xia, H. N.; Jiang, J. C.; Yang, F. J.
2002-05-01
This paper reports the results of the PIXE analysis on ancient Chinese blue and white porcelain fired at Kuan Kiln (Jingdezhen, Jiangxi province) during 13-19th century. The major, minor and trace element of porcelain body, white glaze and blue glaze were determined by PIXE. In this paper the chemical compositions of porcelain body, white glaze and blue glaze measured from Yuan (AD 1206-1368), Ming (AD 1368-1644) and Qing (AD 1616-1911) blue and white porcelain are present. The cobalt blue pigment used in Yuan, Ming and Qing are also discussed.
Nickel toxicity in the hepatopancreas of an isopod Porcellio scaber ( Oniscidea)
NASA Astrophysics Data System (ADS)
Tarnawska, M.; Migula, P.; Przybyłowicz, W.; Mesjasz-Przybyłowicz, J.; Augustyniak, M.
2007-07-01
This study is focused on recognizing how the functional role of hepatopancreas, the main metal storage organ in woodlice, is affected by the excess of nickel, a toxic element to soil invertebrates. Chronic Ni toxicity (24 weeks) was studied on four groups of woodlice kept on dry shredded maple leaves contaminated with Ni at average concentrations of 0.1 μg g -1 (control), 8.0 μg g -1 (Ni1), 75 μg g -1 (Ni2) and 270 μg g -1(Ni3) dry weight. Micro-PIXE mapping of elemental distribution in the hepatopancreas of the Porcellio scaber woodlice was used to study relations between nickel and other elements in individuals exposed to different metal concentrations in the diet. Data were processed using GeoPIXE II software. Transmission electron microscopy (TEM) was used to check the relations between ultrastructural changes in hepatopancreatic cells and nickel tissue burden. Elemental mapping showed a dose-related nickel bioaccumulation in the hepatopancreas at concentrations from 3 μg g -1 (uncontaminated control animals) to nearly 840 μg g -1 (Ni3). Generally, nickel was distributed uniformly in small aggregations. A combined evaluation of elemental maps and electronograms showed that aggregations of nickel in arbitrarily selected micro-areas in PIXE maps could be the granular structures observed in TEM electronograms. The mechanism of Ni sequestration in the hepatopancreas could be similar to this used for cadmium or lead. The sequences of ultrastructural changes, which follow the increased burdens of Ni in the hepatopancreatic cells, were: the increase of intracellular electron-dense granules, increase in the number of myelin-like structures, intensified mitochondrial swelling and appearance of concentrically arranged, rough endoplasmic reticulum.
NASA Astrophysics Data System (ADS)
Reis, M. A.; Chaves, P. C.
2018-02-01
Particle induced X-ray emission (PIXE) is a powerful technique for quantitative analysis because it is non-destructive, multi-elemental (from Na to U), highly sensitive and requires no special sample preparation. Heavy Ions PIXE (HI-PIXE), may represent a further step in versatility but it comes with added complexity of the physical processes involved in X-ray production, which require among other things new software capabilities. In this work, the specific capacities of the DT2 code are used to simulate and fit Ta L- and M-shell spectra obtained during the irradiation of a Ta2O5 thin film deposited upon a polished vitreous graphite substrate, produced in the frame of the Heavy Ions PIXE workpakage of the IAEA Coordinated Research Project F11019 on analytical uses of MeV focused ion beams. Proton and oxygen beams from a duoplasmatron ion source were used, and spectra were collected using both the CdTe and the X-ray Microcalorimeter Spectrometer detectors of the High Resolution High X-ray Energy PIXE (HRHE-PIXE) facility of C2TN. Results obtained from the simulation and the fitting of these spectra are presented and discussed.
Elemental analysis with external-beam PIXE
NASA Astrophysics Data System (ADS)
Lin, E. K.; Wang, C. W.; Teng, P. K.; Huang, Y. M.; Chen, C. Y.
1992-05-01
A beamline system and experimental setup has been established for elemental analysis using PIXE with an external beam. Experiments for the study of the elemental composition of ancient Chinese potsherds (the Min and Ching ages) were performed. Continuum X-ray spectra from the samples bombarded by 3 MeV protons have been measured with a Si(Li) detector. From the analysis of PIXE data, the concentration of the main elements (Al, Si, K, and Ca) and of more than ten trace elements in the matrices and glazed surfaces were determined. Results for two different potsherds are presented, and those obtained from the glaze colorants are compared with the results of measurements on a Ching blue-and-white porcelain vase.
Combined Non-invasive PIXE/PIGE Analyses of Mammoth Ivory from Aurignacian Archaeological Sites.
Reiche, Ina; Heckel, Claire; Müller, Katharina; Jöris, Olaf; Matthies, Tim; Conard, Nicholas J; Floss, Harald; White, Randall
2018-06-18
Among the earliest Homo sapiens societies in Eurasia, the Aurignacian phase of the Early Upper Paleolithic, approximately 40 000-30 000 years ago, mammoth ivory assumed great social and economic significance, and was used to create hundreds of personal ornaments as well as the earliest known works of three-dimensional figurative art in the world. This paper reports on the results of micro-PIXE/PIGE analyses of mammoth-ivory artifacts and debris from five major sites of Aurignacian ivory use. Patterns of variable fluorine content indicate regionally distinctive strategies of ivory procurement that correspond to apparent differences in human-mammoth interactions. Preserved trace elements (Br, Sr, Zn) indicate that differences at the regional level are applicable to sourcing Paleolithic ivory at the regional scale. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
PIXE Analysis of Atmospheric Aerosol Samples Collected in the Adirondack Mountains
NASA Astrophysics Data System (ADS)
Yoskowitz, Josh; Ali, Salina; Nadareski, Benjamin; Safiq, Alexandrea; Smith, Jeremy; Labrake, Scott; Vineyard, Michael
2013-10-01
We have performed an elemental analysis of atmospheric aerosol samples collected at Piseco Lake in Upstate New York using proton induced x-ray emission spectroscopy (PIXE). This work is part of a systematic study of airborne pollution in the Adirondack Mountains. Of particular interest is the sulfur content that can contribute to acid rain, a well-documented problem in the Adirondacks. We used a nine-stage cascade impactor to collect the samples and distribute the particulate matter onto Kapton foils by particle size. The PIXE experiments were performed with 2.2-MeV proton beams from the 1.1-MV pelletron accelerator in the Union College Ion-Beam Analysis Laboratory. X-Ray energy spectra were measured with a silicon drift detector and analyzed with GUPIX software to determine the elemental concentrations of the aerosols. A broad range of elements from silicon to zinc were detected with significant sulfur concentrations measured for particulate matter between 0.25 and 0.5 μm in size. The PIXE analysis will be described and preliminary results will be presented.
Elemental composition and sources of fine and ultrafine ambient particles in Erfurt, Germany.
Cyrys, J; Stölzel, M; Heinrich, J; Kreyling, W G; Menzel, N; Wittmaack, K; Tuch, T; Wichmann, H-Erich
2003-04-15
We present the first results of a source apportionment for the urban aerosol in Erfurt, Germany, for the period 1995-1998. The analysis is based on data of particle number concentrations (0.01-2.5 microm; mean 1.8 x 10(4) cm(-3), continuous), the concentration of the ambient gases SO(2), NO, NO(2) and CO (continuous), particle mass less than 2.5 microm (PM(2.5)) and less than 10 microm (PM(10)) (Harvard Impactor sampling, mean PM(2.5) 26.3 micro/m(3), mean PM(10) 38.2 microg/m(3)) and the size fractionated concentrations of 19 elements (impactor sampling 0.05-1.62 microm, PIXE analysis). We determined: (a) the correlations between (i) the 1- and 24-h average concentrations of the gaseous pollutants and the particle number as well as the particle mass concentration and (ii) between the 24-h elemental concentrations; (b) Crustal Enrichment Factors for the PIXE elements using Si as reference element; and (c) the diurnal pattern of the measured pollutants on weekdays and on weekends. The highly correlated PIXE elements Si, Al, Ti and Ca having low enrichment factors were identified as soil elements. The strong correlation of particle number concentrations with NO, which is considered to be typically emitted by traffic, and the striking similarity of their diurnal variation suggest that a sizable fraction of the particle number concentration is associated with emission from vehicles. Besides NO and particle number concentrations other pollutants such as NO(2), CO as well as the elements Zn and Cu were strongly correlated and appear to reflect motor vehicle traffic. Sulfur could be a tracer for coal combustion, however, it was not correlated with any of the quoted elements. Highly correlated elements V and Ni have similar enrichment factors and are considered as tracers for oil combustion.
Artificial neural networks applied to quantitative elemental analysis of organic material using PIXE
NASA Astrophysics Data System (ADS)
Correa, R.; Chesta, M. A.; Morales, J. R.; Dinator, M. I.; Requena, I.; Vila, I.
2006-08-01
An artificial neural network (ANN) has been trained with real-sample PIXE (particle X-ray induced emission) spectra of organic substances. Following the training stage ANN was applied to a subset of similar samples thus obtaining the elemental concentrations in muscle, liver and gills of Cyprinus carpio. Concentrations obtained with the ANN method are in full agreement with results from one standard analytical procedure, showing the high potentiality of ANN in PIXE quantitative analyses.
Silicon Drift Detector response function for PIXE spectra fitting
NASA Astrophysics Data System (ADS)
Calzolai, G.; Tapinassi, S.; Chiari, M.; Giannoni, M.; Nava, S.; Pazzi, G.; Lucarelli, F.
2018-02-01
The correct determination of the X-ray peak areas in PIXE spectra by fitting with a computer program depends crucially on accurate parameterization of the detector peak response function. In the Guelph PIXE software package, GUPIXWin, one of the most used PIXE spectra analysis code, the response of a semiconductor detector to monochromatic X-ray radiation is described by a linear combination of several analytical functions: a Gaussian profile for the X-ray line itself, and additional tail contributions (exponential tails and step functions) on the low-energy side of the X-ray line to describe incomplete charge collection effects. The literature on the spectral response of silicon X-ray detectors for PIXE applications is rather scarce, in particular data for Silicon Drift Detectors (SDD) and for a large range of X-ray energies are missing. Using a set of analytical functions, the SDD response functions were satisfactorily reproduced for the X-ray energy range 1-15 keV. The behaviour of the parameters involved in the SDD tailing functions with X-ray energy is described by simple polynomial functions, which permit an easy implementation in PIXE spectra fitting codes.
Measuring mercury and other elemental components in tree rings
Gillan, C.; Hollerman, W.A.; Doyle, T.W.; Lewis, T.E.
2004-01-01
There has been considerable interest in measuring heavy metal pollution, such as mercury, using tree ring analysis. Since 1970, this method has provided a historical snapshot of pollutant concentrations near hazardous waste sites. Traditional methods of analysis have long been used with heavy metal pollutants such as mercury. These methods, such as atomic fluorescence and laser ablation, are sometimes time consuming and expensive to implement. In recent years, ion beam techniques, such as Particle Induced X-Ray Emission (PIXE), have been used to measure large numbers of elements. Most of the existing research in this area has been completed for low to medium atomic number pollutants, such as titanium, cobalt, nickel, and copper. Due to the reduction of sensitivity, it is often difficult or impossible to use traditional low energy (few MeV) PIXE analysis for pollutants with large atomic numbers. For example, the PIXE detection limit for mercury was recently measured to be about 1 ppm for a spiked Southern Magnolia wood sample [ref. 1]. This presentation will compare PIXE and standard chemical concentration results for a variety of wood samples.
Measuring mercury and other elemental components in tree rings
Gillan, C.; Hollerman, W.A.; Doyle, T.W.; Lewis, T.E.
2004-01-01
There has been considerable interest in measuring heavy metal pollution, such as mercury, using tree ring analysis. Since 1970, this method has provided a historical snapshot of pollutant concentrations near hazardous waste sites. Traditional methods of analysis have long been used with heavy metal pollutants such as mercury. These methods, such as atomic fluorescence and laser ablation, are sometimes time consuming and expensive to implement. In recent years, ion beam techniques, such as Particle Induced X-Ray Emission (PIXE), have been used to measure large numbers of elements. Most of the existing research in this area has been completed for low to medium atomic number pollutants, such as titanium, cobalt, nickel, and copper. Due to the reduction of sensitivity, it is often difficult or impossible to use traditional low energy (few MeV) PIXE analysis for pollutants with large atomic numbers. For example, the PIXE detection limit for mercury was recently measured to be about 1 ppm for a spiked Southern Magnolia wood sample [ref. 1]. This presentation will compare PIXE and standard chemical concentration results for a variety of wood samples. Copyright 2004 by ISA.
NASA Astrophysics Data System (ADS)
Weiersbye, I. M.; Straker, C. J.; Przybylowicz, W. J.
1999-10-01
A combination of PIXE, proton back-scattering (BS) spectrometry and confocal laser scanning microscopy (CLSM) was used to determine in situ elemental concentrations in arbuscular mycorrhizal (AM) grass roots and AM fungal spores from gold and uranium mine tailings in South Africa. AM regions of roots were characterised by locally elevated P and vesicles were defined by distinctive transition metal and radionuclide distributions. Vesicles (AM structures responsible for nutrient storage), accumulated Mn, Cu, Ni and U, whereas Fe and Zn were present at lower levels than in host tissue. AM spores from mine tailings accumulated Ca, Cr, Fe, Ni, Cu, Br, Y, Th and U, but were deficient in P and K. The sequestration of excess metals and radionuclides in vesicles may limit metal availability, and thus toxicity, to the host.
External-PIXE analysis for the study of pigments from a painting from the Museum of Contemporary Art
NASA Astrophysics Data System (ADS)
Rizzutto, M. A.; Moro, M. V.; Silva, T. F.; Trindade, G. F.; Added, N.; Tabacniks, M. H.; Kajiya, E. M.; Campos, P. H. V.; Magalhães, A. G.; Barbosa, M.
2014-08-01
External Ion Beam Analysis is a useful tool for the characterization of cultural heritage objects. During the last decade, several significant collaborations have been established between Ion Beam Analysis (IBA) scientists and art or archeology professionals, demanding in-air IBA for a variety of different cultural heritage objects. In-air Particle Induced X-ray Emission (PIXE) analyses of an oil painting by the Italian painter, Mario Sironi, from the Museum of Contemporary Art of the University of São Paulo (MAC-USP), were examined. This painting is particularly interesting due to paintings on both sides (oil on canvas on the front and oil on wood on the back side). PIXE analysis helped the identification of the pigment similarities on both sides of the painting, suggesting the same authorship.
betaPIX controls cell motility and neurite extension by regulating the distribution of GIT1.
Za, Lorena; Albertinazzi, Chiara; Paris, Simona; Gagliani, Mariacristina; Tacchetti, Carlo; de Curtis, Ivan
2006-07-01
Cell motility entails the reorganization of the cytoskeleton and membrane trafficking for effective protrusion. GIT1/p95-APP1 is a member of a family of GTPase-activating proteins for ARF GTPases that affect endocytosis, adhesion and migration. GIT1 associates with paxillin and a complex including the Rac/Cdc42 exchanging factors PIX/Cool and the kinase PAK. In this study, we show that overexpression of betaPIX induces the accumulation of endogenous and overexpressed GIT1 at large structures similar to those induced by an ArfGAP-defective mutant of GIT1 (p95-C2). Immunohistochemical analysis and immunoelectron microscopy reveal that these structures include the endogenous transferrin receptor. Time-lapse analysis during motogenic stimuli shows that the formation and perinuclear accumulation of the p95-C2-positive structures is paralleled by inhibition of lamellipodium formation and cell retraction. Both dimerization and a functional SH3 domain of betaPIX are required for the accumulation of GIT1 in fibroblasts, which is prevented by the monomeric PIX-PG-DeltaLZ. This mutant also prevents the formation of endocytic aggregates and inhibition of neurite outgrowth in retinal neurons expressing p95-C2. Our results indicate that betaPIX is an important regulator of the subcellular distribution of GIT1, and suggest that alteration in the level of expression of the complex affects the endocytic compartment and cell motility.
In-air PIXE analysis by means of glass capillary optics
NASA Astrophysics Data System (ADS)
Nebiki, Takuya; Kabir, M. Hasnat; Narusawa, Tadashi
2006-08-01
A novel technique to introduce high energy ion beams to atmospheric environment is presented, which enables in-air PIXE measurements. Slightly tapered glass capillary optics is applied to work as a differential pumping orifice as well as a focusing lens. The flux intensity is enhanced by at least one order of magnitude due to the focusing effect. Using capillaries of 10-20 μm outlet diameters, we obtain several hundreds pA of 4 MeV He2+ ion beam and apply it to PIXE analysis of the seabed sludge without any sample treatments. A comparison of spectra between wet and dry sludge samples suggests the usefulness of our new technique.
An efficient ionoluminescence analysis of turquoise gemstone as a weakly luminescent mineral.
Nikbakht, T; Kakuee, O; Lamehi-Rachti, M
2017-05-15
The unique ionization pattern of MeV-energy ion beam is applied for efficient luminescence analysis of a collection of natural turquoise samples. The considerable penetration depth of tens of micrometer and enhancement of energy deposition with depth, suggests ionoluminescence as an appropriate technique for studying weakly luminescent minerals. Herein, the luminescence induced in deeper parts of turquoise samples is extracted through their relatively transparent adjacent host stones. The resulting intense spectra reveal the vibrational structure of the broad green luminescence band of turquoise which probably originates from O 2 - centers. Moreover, owing to the applied ionoluminescence approach, red and blue luminescence bands of turquoise were observed which can be ascribed to Fe 3+ ions and UO 2 2+ centers respectively. The elemental information of the samples is provided using micro-PIXE analysis technique. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Moretto, P.; Ortega, R.; Llabador, Y.; Simonoff, M.; Bénard, J.; Moretto, Ph.
1995-09-01
Macro-and Micro-PIXE analysis were applied to study the mechanisms of cellular resistance to cisplatin, a chemotherapeutic agent, widely used nowadays for the treatment of ovarian cancer. Two cultured cell lines, a cisplatin-sensitive and a resistant one, were compared for their trace elements content and platinum accumulation following in vitro exposure to the drug. Bulk analysis revealed significant differences in copper and iron content between the two lines. Subsequent individual cell microanalysis permitted us to characterize the response of the different morphological cell types of the resistant line. This study showed that the metabolism of some trace metals in cisplatin-resistant cells could be affected but the exact relationship with the resistant phenotype remains to be determined. From a technical point of view, this experiment demonstrated that an accurate measurement of trace elements could be derived from nuclear microprobe analysis of individual cell.
PIXE Analysis of Aerosol and Soil Samples Collected in the Adirondack Mountains
NASA Astrophysics Data System (ADS)
Yoskowitz, Joshua; Ali, Salina; Nadareski, Benjamin; Labrake, Scott; Vineyard, Michael
2014-09-01
We have performed an elemental analysis of aerosol and soil samples collected at Piseco Lake in Upstate New York using proton induced X-ray emission spectroscopy (PIXE). This work is part of a systematic study of airborne pollution in the Adirondack Mountains. Of particular interest is the sulfur content that can contribute to acid rain, a well-documented problem in the Adirondacks. We used a nine-stage cascade impactor to collect the aerosol samples near Piseco Lake and distribute the particulate matter onto Kapton foils by particle size. The soil samples were also collected at Piseco Lake and pressed into cylindrical pellets for experimentation. PIXE analysis of the aerosol and soil samples were performed with 2.2-MeV proton beams from the 1.1-MV Pelletron accelerator in the Union College Ion-Beam Analysis Laboratory. There are higher concentrations of sulfur at smaller particle sizes (0.25-1 μm), suggesting that it could be suspended in the air for days and originate from sources very far away. Other elements with significant concentrations peak at larger particle sizes (1-4 μm) and are found in the soil samples, suggesting that these elements could originate in the soil. The PIXE analysis will be described and the resulting data will be presented.
NASA Astrophysics Data System (ADS)
Campbell, John L.; Ganly, Brianna; Heirwegh, Christopher M.; Maxwell, John A.
2018-01-01
Multiple ionization satellites are prominent features in X-ray spectra induced by MeV energy alpha particles. It follows that the accuracy of PIXE analysis using alpha particles can be improved if these features are explicitly incorporated in the peak model description when fitting the spectra with GUPIX or other codes for least-squares fitting PIXE spectra and extracting element concentrations. A method for this incorporation is described and is tested using spectra recorded on Mars by the Curiosity rover's alpha particle X-ray spectrometer. These spectra are induced by both PIXE and X-ray fluorescence, resulting in a spectral energy range from ∼1 to ∼25 keV. This range is valuable in determining the energy-channel calibration, which departs from linearity at low X-ray energies. It makes it possible to separate the effects of the satellites from an instrumental non-linearity component. The quality of least-squares spectrum fits is significantly improved, raising the level of confidence in analytical results from alpha-induced PIXE.
Pixe analysis of trace elements in tissues of rats treated with anticonvulsants
NASA Astrophysics Data System (ADS)
Hurd, R. W.; Van Rinsvelt, H. A.; Kinyua, A. M.; O'Neill, M. P.; Wilder, B. J.; Houdayer, A.; Hinrichsen, P. F.
1987-04-01
Several lines of evidence implicate metals in epilepsy. Anticonvulsant drugs are noted to alter levels of metals in humans and animals. PIXE analysis was used to investigate effects of three anticonvulsant drugs on tissue and brain cortex trace elements. The content of zinc and copper was increased in liver and spleen of rats treated with anticonvulsants while selenium was decreased in cortex.
PIXE Analysis of Indoor Aerosols
NASA Astrophysics Data System (ADS)
Johnson, Christopher; Turley, Colin; Moore, Robert; Battaglia, Maria; Labrake, Scott; Vineyard, Michael
2011-10-01
We have performed a proton-induced X-ray emission (PIXE) analysis of aerosol samples collected in academic buildings at Union College to investigate the air quality in these buildings and the effectiveness of their air filtration systems. This is also the commissioning experiment for a new scattering chamber in the Union College Ion-Beam Analysis Laboratory. The aerosol samples were collected on Kapton foils using a nine-stage cascade impactor that separates particles according to their aerodynamic size. The foils were bombarded with beams of 2.2-MeV protons from the Union College 1.1-MV Pelletron Accelerator and the X-ray products were detected with an Amptek silicon drift detector. After subtracting the contribution from the Kapton foils, the X-ray energy spectra of the aerosol samples were analyzed using GUPIX software to determine the elemental concentrations of the samples. We will describe the collection of the aerosol samples, discuss the PIXE analysis, and present the results.
NASA Astrophysics Data System (ADS)
Chiari, M.; Yubero, E.; Calzolai, G.; Lucarelli, F.; Crespo, J.; Galindo, N.; Nicolás, J. F.; Giannoni, M.; Nava, S.
2018-02-01
Within the framework of research projects focusing on the sampling and analysis of airborne particulate matter, Particle Induced X-ray Emission (PIXE) and Energy Dispersive X-ray Fluorescence (ED-XRF) techniques are routinely used in many laboratories throughout the world to determine the elemental concentration of the particulate matter samples. In this work an inter-laboratory comparison of the results obtained from analysing several samples (collected on both Teflon and quartz fibre filters) using both techniques is presented. The samples were analysed by PIXE (in Florence, at the 3 MV Tandetron accelerator of INFN-LABEC laboratory) and by XRF (in Elche, using the ARL Quant'X EDXRF spectrometer with specific conditions optimized for specific groups of elements). The results from the two sets of measurements are in good agreement for all the analysed samples, thus validating the use of the ARL Quant'X EDXRF spectrometer and the selected measurement protocol for the analysis of aerosol samples. Moreover, thanks to the comparison of PIXE and XRF results on Teflon and quartz fibre filters, possible self-absorption effects due to the penetration of the aerosol particles inside the quartz fibre-filters were quantified.
PIXE and XRF Analysis of Roman Denarii
NASA Astrophysics Data System (ADS)
Fasano, Cecilia; Raddell, Mark; Manukyan, Khachatur; Stech, Edward; Wiescher, Michael
2017-09-01
A set of Roman Denarii from the republican to the imperial period (140BC-240AD) has been studied using X-ray fluorescent (XRF) scanning and proton induced x-ray emission (PIXE) techniques. XRF and PIXE are commonly used in the study of cultural heritage objects because they are nondestructive. The combination of these two methods is also unique because of the ability to penetrate the sample with a broader spectrum of depths and energies than either could achieve on its own. The coins are from a large span of Roman history and their analysis serves to follow the economic and political change of the era using the relative silver and copper contents in each sample. In addition to analyzing the samples, the study sought to compare these two common analysis techniques and to explore the use of a standard to examine any shortcomings in either of the methods. Data sets were compared and then adjusted to a calibration curve which was created from the analysis of a number of standard solutions. The concentrations of the standard solutions were confirmed using inductively coupled plasma spectroscopy. Through this we were able to assemble results which will progress the basis of understanding of PIXE and XRF techniques as well as increase the wealth of knowledge of Ancient Roman currency.
PIXE analysis of ancient Chinese Qing dynasty porcelain
NASA Astrophysics Data System (ADS)
Cheng, Huansheng; He, Wenquan; Tang, Jiayong; Yang, Fujia; Wang, Jianhua
1996-09-01
The major and minor chemical compositions and trace element content of white glaze made in Qing dynasty at kuan kiln have been determined by PIXE. Experimental results show that trace element contents RbSrZr are useful to distinguish the place of production of ancient porcelain. In the porcelain from different kilns situated in a same province, the trace element contents can be different from each other. Determining and comparing the major and minor compositions and trace elemental concentrations in white glaze by PIXE technique, we can distinguish a precious Qing dynasty porcelain made at kuan kiln from a fake.
Trace element fingerprinting of jewellery rubies by external beam PIXE
NASA Astrophysics Data System (ADS)
Calligaro, T.; Poirot, J.-P.; Querré, G.
1999-04-01
External beam PIXE analysis allows the non-destructive in situ characterisation of gemstones mounted on jewellery pieces. This technique was used for the determination of the geographical origin of 64 rubies set on a high-valued necklace. The trace element content of these gemstones was measured and compared to that of a set of rubies of known sources. Multivariate statistical processing of the results allowed us to infer the provenance of rubies : one comes from Thailand/Cambodia deposit while the remaining are attributed to Burma. This highlights the complementary capabilities of PIXE and conventional gemological observations.
Sugimoto, Yuki; Nakamura, Hiroshi; Ren, Shukun; Hori, Koichi; Masuda, Shinji
2017-03-01
The Synechocystis sp. PCC6803 can move on a solid surface in response to light, a phenomenon called phototaxis. Although many of the photoreceptors involved in phototaxis have been identified, the mechanisms that regulate directional motility of Synechocystis are not well understood. Previous studies showed that a mutant lacking the blue light-using flavin (BLUF) photoreceptor PixD exhibits negative phototaxis under conditions where the wild type responds positively. PixD interacts with the pseudo-response regulator-like protein PixE in a light-dependent manner, suggesting that this intermolecular interaction is important for phototaxis regulation, although genetic evidence has been lacking. To gain further insight into phototaxis regulation by PixD-PixE signaling, we constructed the deletion mutants ΔPixE and ΔPixD-ΔPixE, and characterized their phenotypes, which matched those of the wild type (positive phototaxis). Because ΔPixD exhibited negative phototaxis, PixE must function downstream of PixD. Under intense blue light (>100 μmol m-2 s-1; 470 nm) the wild type exhibited negative phototaxis, but ΔPixD-PixE exhibited positive phototaxis toward low-intensity blue light (∼0.8 μmol m-2 s-1; 470 nm). These results suggest that an unknown light-sensing system(s), that is necessary for directional cell movement, can be activated by low-intensity blue light; on the other hand, PixD needs high-intensity blue light to be activated. We also isolated spontaneous mutants that compensated for the pixE deletion. Genome-wide sequencing of the mutants revealed that the uncharacterized gene sll2003 regulates positive and negative phototaxis in response to light intensity. © The Author 2016. Published by Oxford University Press on behalf of Japanese Society of Plant Physiologists. All rights reserved. For permissions, please email: journals.permissions@oup.com.
Fish gelatin thin film standards for biological application of PIXE
NASA Astrophysics Data System (ADS)
Manuel, Jack E.; Rout, Bibhudutta; Szilasi, Szabolcs Z.; Bohara, Gyanendra; Deaton, James; Luyombya, Henry; Briski, Karen P.; Glass, Gary A.
2014-08-01
There exists a critical need to understand the flow and accumulation of metallic ions, both naturally occurring and those introduced to biological systems. In this paper the results of fabricating thin film elemental biological standards containing nearly any combination of trace elements in a protein matrix are presented. Because it is capable of high elemental sensitivity, particle induced X-ray emission spectrometry (PIXE) is an excellent candidate for in situ analysis of biological tissues. Additionally, the utilization of microbeam PIXE allows the determination of elemental concentrations in and around biological cells. However, obtaining elemental reference standards with the same matrix constituents as brain tissue is difficult. An excellent choice for simulating brain-like tissue is Norland® photoengraving glue which is derived from fish skin. Fish glue is water soluble, liquid at room temperature, and resistant to dilute acid. It can also be formed into a thin membrane which dries into a durable, self-supporting film. Elements of interest are introduced to the fish glue in precise volumetric additions of well quantified atomic absorption standard solutions. In this study GeoPIXE analysis package is used to quantify elements intrinsic to the fish glue as well as trace amounts of manganese added to the sample. Elastic (non-Rutherford) backscattered spectroscopy (EBS) and the 1.734 MeV proton-on-carbon 12C(p,p)12C resonance is used for a normalization scheme of the PIXE spectra to account for any discrepancies in X-ray production arising from thickness variation of the prepared standards. It is demonstrated that greater additions of the atomic absorption standard cause a viscosity reduction of the liquid fish glue resulting in thinner films but the film thickness can be monitored by using simultaneous PIXE and EBS proton data acquisition.
Determination of Hg concentration in gases by PIXE
NASA Astrophysics Data System (ADS)
Dutkiewicz, E.; van Kuijen, W. J. P.; Munnik, F.; Mutsaers, P. H. A.; Rokita, E.; de Voigt, M. J. A.
1992-05-01
A method for determination of the concentration of mercury in the gaseous phase is described. In the first step of the method a stable sulphur-mercury complex is formed. For this purpose sulphur is deposited on a filter and the investigated gas flows through the filter. Millipore filters and the deposition of sulphur from Na2S2O3 * 5H2O solution were found to be most suitable. The amount of Hg absorbed on the filter was determined by PIXE or by NAA in the second step of the method. An optimization of proton energy was performed in the PIXE analysis to obtain the maximal signal-to-background ratio. The detection limit of the method, expressed as the minimal amount of Hg which has to flow through the filter equals to 30 and 2 ng for PIXE and NAA techniques, respectively. Applications of the method are also described.
Heaven and Earth - `Madonne col Bambino' and `Rustiques figulines'
NASA Astrophysics Data System (ADS)
Bouquillon, A.
Analyses of the productions of della Robbia and Palissy, two masters of Renaissance ceramics in France and in Italy, have enlightened their contributions to the improvement of the glazed terracotta technique. Della Robbia used very homogeneous materials: marly clay for the bodies, and tin-opacified coloured glazes. The technique is here very robust and very mastered. Palissy used different types of clay with different colours and physical properties, associated with specific productions. So far, we have identified seven pastes. Concerning the glazes, he played with transparency and opacity, with lead glazes and with tin-opacified lead glazes. He added traditional colouring oxides as well as specific pigments (lead-tin yellow, haematite, etc.). The mixed-earth technique is specific to his palette. So, the materials used by both artists are completely different and illustrate their different philosophical approaches. To perform the different analyses, new methodologies have been developed: ICP/AES-MS, petrography and X-ray diffractometry for the bodies, PIXE and micro-PIXE, SEM coupled with EDS and Raman spectrometry for the glazes.
Ion beam modification of zinc white pigment characterized by ex situ and in situ μ-Raman and XPS
NASA Astrophysics Data System (ADS)
Beck, L.; Gutiérrez, P. C.; Miro, S.; Miserque, F.
2017-10-01
Zinc oxide, known as zinc white, is one of the principal white pigments developed in the 18th century and was used by the Impressionist painters. ZnO as artists' pigment has occasionally been characterized by X-ray and ion beam techniques, but these studies are limited by the potential for visible radiation effect. Ion beam modifications of zinc oxide have extensively been investigated, but mainly for electronic and industrial applications. In this paper, we focus our investigation on ion beam modification of ZnO used as pigment. Two irradiation conditions have been used: an external 3 MeV proton micro-beam representative of PIXE analysis and 2 MeV H+ and 1.2 MeV Au + beams in vacuum to investigate irradiation modifications in electronic and nuclear energy loss regimes. Ion beam modification was characterized by ex situ and in situ micro-Raman spectrometry and XPS. The results shows that IBA of zinc white can be carried out safely in historical paintings with low current and dose.
PIXE Analysis of Ceramic Artifacts
NASA Astrophysics Data System (ADS)
High, Elizabeth; Lamm, Larry; Schurr, Mark; Stech, Edward; Wiescher, Michael
2009-10-01
Particle Induced X-ray Emissions, or PIXE, is a nuclear physics technique used as a non-destructive material analysis method which gives a detailed and comprehensive profile of the elemental composition of a target. Using the University of Notre Dame KN and FN accelerators in the ISNAP laboratory a beam of particles, here protons, is accelerated and used to knock out electrons from lower orbitals within the target resulting in characteristic X-rays. Under optimum operating conditions data from PIXE can not only give information about which elements are present in a sample but also their relative abundances in parts per million. In a previous run done in collaboration with the Anthropology Department at the University of Notre Dame pottery shards from the Collier Lodge, located in northwest Indiana, were analyzed and only relative abundances were able to be compared between samples. We are now implementing a new setup into the beam-line which will incorporate the ability to take Rutherford Back Scattering, or RBS, measurements of the beam during the PIXE runs, which will allow for a standard normalization for the runs and give the facility the ability to acquire a more absolute and quantitative analysis of the data. Initial results using the same pottery shards as a comparative data set will be presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vilarigues, M., E-mail: mgv@fct.unl.pt; Redol, P.; Monastery of Batalha, P-2440
2011-02-15
This paper reports the study of corrosion in two stained glass panels from the south aisle of Sta. Maria da Vitoria monastery, at Batalha (Portugal), one depicting the Last Supper (dated from 1508), and the other one showing a saint (c. 1450). These panels exhibit extensive corrosion with darkening phenomena that are an impediment to their correct visualization, a source of major concern both to conservators and curators. By using external micro-beam Particle Induced X-ray Emission (PIXE) and Particle Induced Gamma Emission (PIGE) spectrometry, the elemental compositions of large fragments were obtained, enabling the selection of representative corroded areas, frommore » which elemental distribution maps were produced by scanning. Calcium and potassium rich structures were found - at the surface and inside cavities in the glass - that were identified as oxalates and carbonates, by Raman microscopy and micro-FTIR. The dark spots present in the glass surfaces were found to be Zn and Pb rich. These findings indicate that the corrosion observed was due not only to reactions with atmospheric water and CO{sub 2} but also with the oxalic acid secreted by micro-organisms. Furthermore, it did not result from reactions with atmospheric SO{sub 2} or acid rain. The information obtained is relevant for a better understanding of the corrosion processes and products formed on the surface of these panels and therefore for the proper planning of much needed adequate conservation-restoration actions and appropriate display conditions. - Research Highlights: {yields} Corrosion and darkening of stained glasses is of concern to conservators and curators. {yields} A multi-technique approach is of relevance to study stained glass corrosion. {yields} External beam PIXE-PIGE provide valuable insight on stained glass corrosion.« less
An attempt to diagnose cancer by PIXE
NASA Astrophysics Data System (ADS)
Uda, M.; Maeda, K.; Sasa, Y.; Kusuyama, H.; Yokode, Y.
1987-03-01
PIXE is suitable especially for trace elemental analysis for atoms with high atomic numbers, which are contained in matrices composed mainly of light elements such as biological materials. An attempt has been made to distinguish elemental concentrations of cancer tissues from those of normal ones. Kidney, testis and urinary bladder cancer tissues were examined by PIXE. Key elements to diagnose these cancers were Ca, Ti, Cr, Fe and Zn. Enrichment of Fe and Ti, and deficiency of Zn could be seen in the kidney cancer. An opposite tendency was observed in the testicular cancer. Imbalance of these elemental concentrations in characteristic organs might give us a possibility for cancer diagnosis.
PIXE analysis of Chinese ancient greenish white porcelain
NASA Astrophysics Data System (ADS)
Cheng, Lin; Ding, Xun-liang; Feng, Song-lin; Cheng, Huang-sheng; Zhang, Wen-Jiang; Fan, Chang-Sheng
2006-03-01
This paper reports the results about the PIXE analysis of major, minor and trace elements of Chinese ancient greenish white porcelain and blue-and-white porcelain produced in Hutian Kiln (Jingdezhen district, Jiangxi province) during 10th-14th centuries. The porcelain body and greenish white glaze from northern Song (AD 960), southern Song (AD 1037-1276), early Yuan (AD 1279-1320), later Yuan (AD 1320-1368) were investigated together with white-and-blue glaze from Ming dynasty (AD 1368-1644). The obtained data were further analyzed by factor analysis.
NASA Astrophysics Data System (ADS)
Afarideh, H.; Amirabadi, A.; Hadji-Saeid, S. M.; Mansourian, N.; Kaviani, K.; Zibafar, E.
1996-04-01
In the present biomedical research, PIXE a powerful technique for elemental analysis was employed to illustrate the importance of multi-elemental determination of serum trace elements in two cases of great medical interest. Those are evaluation of the desferroxamine drug (DPO), a widely used therapy for patient with β-thalassemia-Major (β-thal-M), and investigation of elemental variations in blood-serum in hyperbilirubinamia new-borns before and after blood transfusion (BT). The purpose of the work is to demonstrate the various aspects of PIXE analysis by some practical examples as well as to draw some general conclusions regarding the cure of those patients with the above mentioned disorders or diseases. To present in details each case, we divide the paper in two parts: part 1 and part 2 to consider the experimental procedure as well as the results individually.
Trace elemental analysis of Indian natural moonstone gems by PIXE and XRD techniques.
Venkateswara Rao, R; Venkateswarulu, P; Kasipathi, C; Sivajyothi, S
2013-12-01
A selected number of Indian Eastern Ghats natural moonstone gems were studied with a powerful nuclear analytical and non-destructive Proton Induced X-ray Emission (PIXE) technique. Thirteen elements, including V, Co, Ni, Zn, Ga, Ba and Pb, were identified in these moonstones and may be useful in interpreting the various geochemical conditions and the probable cause of their inceptions in the moonstone gemstone matrix. Furthermore, preliminary XRD studies of different moonstone patterns were performed. The PIXE technique is a powerful method for quickly determining the elemental concentration of a substance. A 3MeV proton beam was employed to excite the samples. The chemical constituents of moonstones from parts of the Eastern Ghats geological formations of Andhra Pradesh, India were determined, and gemological studies were performed on those gems. The crystal structure and the lattice parameters of the moonstones were estimated using X-Ray Diffraction studies, trace and minor elements were determined using the PIXE technique, and major compositional elements were confirmed by XRD. In the present work, the usefulness and versatility of the PIXE technique for research in geo-scientific methodology is established. © 2013 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Constantinescu, Bogdan; Cristea-Stan, Daniela; Szőkefalvi-Nagy, Zoltán; Kovács, Imre; Harsányi, Ildikó; Kasztovszky, Zsolt
2018-02-01
Combined external milli-beam Particle Induced X-ray Emission (PIXE) and Prompt Gamma Activation Analysis (PGAA) analysis was applied to characterize the composition of paste and colorants from some fragments of Byzantine bracelets (10th-12th Centuries AD), late medieval (17th-18th Centuries AD) and modern Murano glass pieces. As fluxes, PGAA revealed the samples are soda-lime glass, except four samples - two medieval vessel white shards and two dark Byzantine fragments of bracelets - which have potash flux. Aluminium was detected in various proportions in all samples indicating different sources for the added sand. The presence of Magnesium is relevant only in one bracelet fragment suggesting the use of plant (wood?) ash and confirming that the Byzantine bracelet is manufactured from the mixture of both types of glass (natron and plant ash based). PGAA also indicated the presence of low quantities of Cadmium, high level of Arsenic and Lead (possibly lead arsenate) in one medieval sample and of ZnO in Murano glass, and of CoO traces (maximum 0.1%) in all blue-colored Byzantine, late medieval to modern Murano glass artefacts. PIXE confirmed the use of small quantities of CoO for blue color, indicated Manganese combined with Iron for dark glass, Copper for green, Lead, Tin and an Arsenic compound (orpiment?) for yellow and in the case of modern Murano glass Selenium and Cadmium to obtain a reddish color. Despite PIXE - PIGE combination is probably the best one for glass analysis, our external milli-PIXE - PGAA methods proved to be adequate complementary tools to determine many chemical elements from glass composition - Si, Na, K, Ca, Al, Mg, various metallic oxides.
Dale, M P; Hackney, D D
1987-12-15
A method for analysis of positional isotope exchange (PIX) during ATP in equilibrium with HOH oxygen exchange is presented that uses a two-step degradation of ATP resulting in cleavage of the beta P-O gamma P bond. This cleavage yields Pi derived from the gamma-phosphoryl of ATP that contains all four of the gamma oxygens. Both PIX between the beta,gamma-bridge and beta-nonbridge positions and washout of the gamma-nonbridge oxygens can be simultaneously followed by using ATP labeled with 17O at the beta-nonbridge positions and 18O at the beta,gamma-bridge and gamma-nonbridge positions. Application of this method to ATP in equilibrium with HOH exchange during single turnovers of myosin indicates that the bulk of the ATP undergoes rapid washout of gamma-nonbridge oxygens in the virtual absence of PIX. At 25 degrees C with subfragment 1 the scrambling rate is at the limit of detectability of approximately 0.001 s-1, which is 50-fold slower than the steady-state rate. This corresponds to a probability of scrambling for the beta-oxygens of bound ADP of 1 in 10,000 for each cycle of reversible hydrolysis of bound ATP. A fraction of the ATP, however, does not undergo rapid washout. With myosin and stoichiometric ATP at 0 degrees C, this fraction corresponds to 10% of the ATP remaining at 36 s, or 2% of the initial ATP, and an equivalent level of ATP is found that does not bind irreversibly to myosin in a cold chase experiment. A significant level of apparent PIX is observed with subfragment 1 in the fraction that resists washout, and this apparent PIX is shown to be due to contaminant adenylate kinase activity. This apparent PIX due to adenylate kinase provides a possible explanation for the PIX observed by Geeves et al. [Geeves, M. A., Webb, M. R., Midelfort, C. F., & Trentham, D. R. (1980) Biochemistry 19, 4748-4754] with subfragment 1.
Kortüm, Fanny; Harms, Frederike Leonie; Hennighausen, Natascha; Rosenberger, Georg
2015-01-01
Endosomal sorting is an essential control mechanism for signaling through the epidermal growth factor receptor (EGFR). We report here that the guanine nucleotide exchange factor αPIX, which modulates the activity of Rho-GTPases, is a potent bimodal regulator of EGFR trafficking. αPIX interacts with the E3 ubiquitin ligase c-Cbl, an enzyme that attaches ubiquitin to EGFR, thereby labelling this tyrosine kinase receptor for lysosomal degradation. We show that EGF stimulation induces αPIX::c-Cbl complex formation. Simultaneously, αPIX and c-Cbl protein levels decrease, which depends on both αPIX binding to c-Cbl and c-Cbl ubiquitin ligase activity. Through interaction αPIX sequesters c-Cbl from EGFR and this results in reduced EGFR ubiquitination and decreased EGFR degradation upon EGF treatment. However, quantitatively more decisive for cellular EGFR distribution than impaired EGFR degradation is a strong stimulating effect of αPIX on EGFR recycling to the cell surface. This function depends on the GIT binding domain of αPIX but not on interaction with c-Cbl or αPIX exchange activity. In summary, our data demonstrate a previously unappreciated function of αPIX as a strong promoter of EGFR recycling. We suggest that the novel recycling regulator αPIX and the degradation factor c-Cbl closely cooperate in the regulation of EGFR trafficking: uncomplexed αPIX and c-Cbl mediate a positive and a negative feedback on EGFR signaling, respectively; αPIX::c-Cbl complex formation, however, results in mutual inhibition, which may reflect a stable condition in the homeostasis of EGF-induced signal flow. PMID:26177020
PIXE analysis of Nigerian flour and bread samples
NASA Astrophysics Data System (ADS)
Olise, Felix S.; Fernandes, Adriana M.; Cristina Chaves, P.; Taborda, Ana; Reis, Miguel A.
2014-01-01
The alleged use of potassium bromate (KBrO3) in bread baking led a few authors to report on the chemical methods for the determination of KBrO3 levels in bread. In order to examine the potentials of a non chemical particle induced X-ray emission (PIXE) method for this purpose, six sets of samples, each composed of flour, dough and bread from a production batch were analysed. The samples were obtained from six different bakers of bread at Ile-Ife, Nigeria. The flour samples were air-dried while others were freeze dried at about -16 °C. The samples were homogenised in an agate mortar and then pelletised. Samples were analysed at the CTN standard PIXE setup and standard procedures for thick target samples analysis were followed. In some samples significant concentrations of bromine were found. In the present work we present possible explanations for the presence of this potentially dangerous contaminant in the samples.
NASA Astrophysics Data System (ADS)
Naga Raju, G. J.; Sarita, P.; Murthy, K. S. R.
2017-08-01
Particle Induced X-ray Emission (PIXE), an accelerator based analytical technique has been employed in this work for the analysis of trace elements in the cancerous and non-cancerous tissues of rectal cancer patients. A beam of 3 MeV protons generated from 3 MV Pelletron accelerator at the Ion Beam Laboratory of Institute of Physics, Bhubaneswar, India was used as projectile to excite the atoms present in the tissues samples. PIXE technique, with its capability to detect simultaneously several elements present at very low concentrations, offers an excellent tool for trace element analysis. The characteristic X-rays emitted by the samples were recorded by a high resolution Si (Li) detector. On the basis of the PIXE spectrum obtained for each sample, the elements Cl, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, and Br were identified and their relative concentrations were estimated in the cancerous and non-cancerous tissues of rectum. The levels of Mn, Fe, Co, Cu, Zn, and As were higher (p < 0.005) while the levels of Ca, Cr and Ni were lower (p < 0.005) in the cancer tissues relative to the normal tissues. The alterations in the levels of the trace elements observed in the present work are discussed in this paper with respect to their potential role in the initiation, promotion and inhibition of cancer of the rectum.
NASA Astrophysics Data System (ADS)
Rihawy, M. S.; Alwazzeh, M.; Abbas, K.
2018-01-01
Ion beam analysis (IBA) techniques (Particle Induced X-ray Emission, PIXE and Elastic Backscattering Spectrometry, EBS), were applied to investigate chloride and sulfate ions diffusion into laboratory prepared mortar samples. Development and characterization of an automated in-vacuum macro PIXE/EBS system is thoroughly discussed. Depth profile information of both chloride and sulfate ions in laboratory prepared mortar samples, after immersion in sea water for nine months, was rapidly and easily obtained at fairly low cost and with standardless analysis, demonstrating the value of the application of IBA to elemental depth profiling in cementitious materials. Chloride and sulfate depth profiles were obtained for two sets of mortar samples, one prepared with different water/cement (W/C) ratios and the other with different sand/cement (S/C) ratios. Results showed higher diffusion rates of both chloride and sulfate ions when both ratios are increased. Additionally, the W/C ratio has a stronger influence in both sulfate and chloride penetration than the S/C ratio, and chloride ions penetrate faster than sulfates. Advantages and limitations of applying IBA techniques in this investigation are discussed. The comparison between PIXE and other X-ray based analytical techniques, namely X-ray fluorescence (XRF) and energy and wavelength dispersive X-rays (EDX/WDX), as well as other traditional wet chemical methods is reviewed, and industrial applications are discussed.
NASA Astrophysics Data System (ADS)
Orlić, Ivica; Mekterović, Darko; Mekterović, Igor; Ivošević, Tatjana
2015-11-01
VIBA-Lab is a computer program originally developed by the author and co-workers at the National University of Singapore (NUS) as an interactive software package for simulation of Particle Induced X-ray Emission and Rutherford Backscattering Spectra. The original program is redeveloped to a VIBA-Lab 3.0 in which the user can perform semi-quantitative analysis by comparing simulated and measured spectra as well as simulate 2D elemental maps for a given 3D sample composition. The latest version has a new and more versatile user interface. It also has the latest data set of fundamental parameters such as Coster-Kronig transition rates, fluorescence yields, mass absorption coefficients and ionization cross sections for K and L lines in a wider energy range than the original program. Our short-term plan is to introduce routine for quantitative analysis for multiple PIXE and XRF excitations. VIBA-Lab is an excellent teaching tool for students and researchers in using PIXE and RBS techniques. At the same time the program helps when planning an experiment and when optimizing experimental parameters such as incident ions, their energy, detector specifications, filters, geometry, etc. By "running" a virtual experiment the user can test various scenarios until the optimal PIXE and BS spectra are obtained and in this way save a lot of expensive machine time.
Status of ion sources at National Institute of Radiological Sciences.
Kitagawa, A; Fujita, T; Goto, A; Hattori, T; Hamano, T; Hojo, S; Honma, T; Imaseki, H; Katagiri, K; Muramatsu, M; Sakamoto, Y; Sekiguchi, M; Suda, M; Sugiura, A; Suya, N
2012-02-01
The National Institute of Radiological Sciences (NIRS) maintains various ion accelerators in order to study the effects of radiation of the human body and medical uses of radiation. Two electrostatic tandem accelerators and three cyclotrons delivered by commercial companies have offered various life science tools; these include proton-induced x-ray emission analysis (PIXE), micro beam irradiation, neutron exposure, and radioisotope tracers and probes. A duoplasmatron, a multicusp ion source, a penning ion source (PIG), and an electron cyclotron resonance ion source (ECRIS) are in operation for these purposes. The Heavy-Ion Medical Accelerator in Chiba (HIMAC) is an accelerator complex for heavy-ion radiotherapy, fully developed by NIRS. HIMAC is utilized not only for daily treatment with the carbon beam but also for fundamental experiments. Several ECRISs and a PIG at HIMAC satisfy various research and clinical requirements.
NASA Astrophysics Data System (ADS)
Pineda-Vargas, C. A.; Eisa, M. E.; Chikte, U. M. E.; Conradie, J. L.
2004-10-01
The process of demineralisation in tooth erosion due to exposure to acidic media was investigated in a group of test and control healthy human molar teeth. Analysis by micro-PIXE and proton-backscattering showed that the levels of trace elements were enriched and/or depleted according to experimental treatment. The atomic ratios of major constituents in the matrix were characteristic of test or controls with typical ratios: O 5P 1Ca 3F 1 for tests and O 6P 0.5Ca 3F 0.5 for controls. The correlation between maps of Ca and Zn in and around the interface between dentine and enamel in control samples showed two kinds of correlation strengths (for enamel and dentine). The strongest correlation was related to the enamel area.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kitagawa, A.; Fujita, T.; Goto, A.
The National Institute of Radiological Sciences (NIRS) maintains various ion accelerators in order to study the effects of radiation of the human body and medical uses of radiation. Two electrostatic tandem accelerators and three cyclotrons delivered by commercial companies have offered various life science tools; these include proton-induced x-ray emission analysis (PIXE), micro beam irradiation, neutron exposure, and radioisotope tracers and probes. A duoplasmatron, a multicusp ion source, a penning ion source (PIG), and an electron cyclotron resonance ion source (ECRIS) are in operation for these purposes. The Heavy-Ion Medical Accelerator in Chiba (HIMAC) is an accelerator complex for heavy-ionmore » radiotherapy, fully developed by NIRS. HIMAC is utilized not only for daily treatment with the carbon beam but also for fundamental experiments. Several ECRISs and a PIG at HIMAC satisfy various research and clinical requirements.« less
Status of ion sources at National Institute of Radiological Sciencesa)
NASA Astrophysics Data System (ADS)
Kitagawa, A.; Fujita, T.; Goto, A.; Hattori, T.; Hamano, T.; Hojo, S.; Honma, T.; Imaseki, H.; Katagiri, K.; Muramatsu, M.; Sakamoto, Y.; Sekiguchi, M.; Suda, M.; Sugiura, A.; Suya, N.
2012-02-01
The National Institute of Radiological Sciences (NIRS) maintains various ion accelerators in order to study the effects of radiation of the human body and medical uses of radiation. Two electrostatic tandem accelerators and three cyclotrons delivered by commercial companies have offered various life science tools; these include proton-induced x-ray emission analysis (PIXE), micro beam irradiation, neutron exposure, and radioisotope tracers and probes. A duoplasmatron, a multicusp ion source, a penning ion source (PIG), and an electron cyclotron resonance ion source (ECRIS) are in operation for these purposes. The Heavy-Ion Medical Accelerator in Chiba (HIMAC) is an accelerator complex for heavy-ion radiotherapy, fully developed by NIRS. HIMAC is utilized not only for daily treatment with the carbon beam but also for fundamental experiments. Several ECRISs and a PIG at HIMAC satisfy various research and clinical requirements.
NASA Astrophysics Data System (ADS)
Ishii, K.; Fujita, A.; Toyama, S.; Terakawa, A.; Matsuyama, S.; Arai, H.; Osada, N.; Takyu, S.; Matsuyama, T.; Koshio, S.; Watanabe, K.; Ito, S.; Kasahara, K.
Edible wild plants growing in the area around the Fukushima Daiichi nuclear power plant remain contaminated. It is important to identify plants with low levels of contamination for the restoration of agriculture in the area. We collected specimens of 10 wild plant species growing in Iitate village which is one of the most highly contaminated areas and also sampled the soil beneath each plant. We measured the specific activity of 137Cs and the concentrations of Na, Mg, Al, Si, P, S, K, Ca, Fe, Zn, Rb and Sr in these samples using a germanium detector and PIXE analysis, respectively. We compared the soil-plant transfer coefficient of 137Cs with those of each element and determined their correlation with 137Cs. It was found that a low Sr transfer coefficient could be used to determine the plants with a low 137Cs transfer coefficient. We suggest that PIXE analysis is a useful analysis technique for agricultural remediation projects in highly contaminated areas around the Fukushima Daiichi nuclear power plant.
Cadmium concentrations in the brains of Alzheimer cases
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spyrou, N.M.; Stedman, J.D.
1996-12-31
There is ongoing research in relating the concentration of elements in the brain with Alzheimer`s disease. The presence of particular elements, such as aluminum and vanadium, has been considered as a possible environmental factor, creating significant interest and controversy in the field. We have been analyzing brain tissue from the MRC Alzheimer`s Disease Brain Bank, Institute of Psychiatry, from a number of cortical regions of the brain, namely, the frontal, occipital, parietal, and temporal lobes, as well as from the left and right hemispheres of the same brain whenever possible. The techniques employed have been proton-induced X-ray emission (PIXE) analysis,more » proton-induced gamma-ray emission (PIGE) analysis, Rutherford backscattering (RBS), and instrumental neutron activation analysis. Neutron irradiations were carried out at the Imperial College Consort II reactor, whereas for PIXE, PIGE, and RBS, the University of Surrey Accelerator Laboratories were used employing a Van de Graaff accelerator. In this paper, we present the cadmium results from the frontal lobe of Alzheimer cases and controls determined by PIXE analysis.« less
The Elemental Analysis of Biological and Environmental Materials Using a 2MEV Proton Beam
NASA Astrophysics Data System (ADS)
Arshed, Waheed
Available from UMI in association with The British Library. A programme has been developed to simulate the proton induced x-ray emission (PIXE) spectra and its uses have been described. The PIXE technique has been applied to the analysis of new biological reference materials which consist of IAEA human diet samples and NIST leaf samples. Homogeneity of these and two existing reference materials, IAEA soil -7 and Bowen's kale, has also been determined at the mug scale. A subsample representative of a material is ascertained by determination of sampling factors for the elements detected in the material. Proton induced gamma-ray emission (PIGE) analysis in conjunction with PIXE has been employed to investigate F and other elemental concentrations found in human teeth samples. The mean F concentration in enamel and dentine parts of teeth followed an age dependent model. Concentrations of Ca and P were found to be higher in the enamel than in the dentine. Analysis of blood and its components in the study of elemental models in sickle cell disease in Nigerians has been carried out. Comparisons revealed that Cl, Ca and Cu were at higher levels whereas K, Fe, Zn and Rb were at lower levels in the whole blood of the sicklers compared to controls. Similar results were obtained for the erythrocytes except that Br was found at higher concentration in erythrocytes of the sicklers. Higher concentrations of Cl, K, Fe and Cu were also observed in plasma of the sicklers compared to controls. PIXE and scanning electron microscopy (SEM) were used in the characterization of the Harmattan dust particulates collected at Kano and Ife. Most of the elements were found to be at higher concentrations as compared to those found in Recife (Brazil) and Toronto (Canada). The value of total suspended particulate was above the relevant national air quality standards. PIXE in conjunction with Rutherford backscattering spectrometry and instrumental neutron activation analysis was employed in the analysis of soil samples detecting 31 elements. The results have been discussed with reference to elemental concentrations and Ca/Si ratio. The latter was a valid indicator of soil pollution by the cement dust. (Abstract shortened by UMI.).
New approaches for investigating paintings by ion beam techniques
NASA Astrophysics Data System (ADS)
Beck, L.; de Viguerie, L.; Walter, Ph.; Pichon, L.; Gutiérrez, P. C.; Salomon, J.; Menu, M.; Sorieul, S.
2010-06-01
Up to now, among the IBA techniques, only PIXE has been used for analyzing paintings. However, quantitative PIXE analysis is sometimes difficult to interpret due to the layered structure, the presence of varnish and organic binder and, in some cases, discoloration of the pigments has been observed due to the interaction of the ion beam with the compounds. In order to improve the characterization of paintings, we propose some alternative experimental procedures. First of all, backscattering spectrometry (BS) and PIXE are simultaneously combined in order to collect complementary information such as layer thickness and organic compound quantification. The simultaneous PIXE and BS experiments also have the advantage of being able to analyze the same area in one experiment. This combination, implemented with an external beam, was directly applied on paintings and on painting cross-sections for the study of Italian Renaissance masterpieces. We have obtained valuable results not only on the pigment itself but also, for the first time, on the binder to pigment proportion which is not well documented in the ancient recipes. Moreover, in order to restrain beam damages due to the ion stopping power, we propose to analyze very thin painting cross-sections by a combination of PIXE-RBS and Scanning Transmission Ion Microscopy (STIM).
High energy PIXE: A tool to characterize multi-layer thick samples
NASA Astrophysics Data System (ADS)
Subercaze, A.; Koumeir, C.; Métivier, V.; Servagent, N.; Guertin, A.; Haddad, F.
2018-02-01
High energy PIXE is a useful and non-destructive tool to characterize multi-layer thick samples such as cultural heritage objects. In a previous work, we demonstrated the possibility to perform quantitative analysis of simple multi-layer samples using high energy PIXE, without any assumption on their composition. In this work an in-depth study of the parameters involved in the method previously published is proposed. Its extension to more complex samples with a repeated layer is also presented. Experiments have been performed at the ARRONAX cyclotron using 68 MeV protons. The thicknesses and sequences of a multi-layer sample including two different layers of the same element have been determined. Performances and limits of this method are presented and discussed.
c-Cbl regulates αPix-mediated cell migration and invasion
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seong, Min Woo; Park, Ji Ho; Yoo, Hee Min
2014-12-12
Highlights: • c-Cbl ubiquitinates αPix for proteasome-mediated degradation. • C6 and A172 glioma cells lack c-Cbl, which leads to stabilization of αPix. • The accumulated αPix promotes migration and invasion of the cancer cells. • The lack of c-Cbl in the cells appears responsible for their malignant behavior. - Abstract: c-Cbl, a RING-type ubiquitin E3 ligase, down-regulates receptor tyrosine kinases, including EGF receptor, and inhibits cell proliferation. Moreover, c-Cbl mutations are frequently found in patients with myeloid neoplasm. Therefore, c-Cbl is known as a tumor suppressor. αPix is expressed only in highly proliferative and mobile cells, including immune cells, andmore » up-regulated in certain invasive tumors, such as glioblastoma multiforme. Here, we showed that c-Cbl serves as an ubiquitin E3 ligase for proteasome-mediated degradation of αPix, but not βPix. Remarkably, the rat C6 and human A172 glioma cells were unable to express c-Cbl, which leads to a dramatic accumulation of αPix. Depletion of αPix by shRNA markedly reduced the ability of the glioma cells to migrate and invade, whereas complementation of shRNA-insensitive αPix promoted it. These results indicate that c-Cbl negatively regulates αPix-mediated cell migration and invasion and the lack of c-Cbl in the C6 and A172 glioma cells is responsible for their malignant behavior.« less
Future of ePix detectors for high repetition rate FELs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Blaj, G., E-mail: blaj@slac.stanford.edu; Caragiulo, P.; Carini, G.
2016-07-27
Free-electron lasers (FELs) made the imaging of atoms and molecules in motion possible, opening new science opportunities with high brilliance, ultra-short x-ray laser pulses at up to 120 Hz. Some new or upgraded FEL facilities will operate at greatly increased pulse rates (kHz to MHz), presenting additional requirements on detection. We will present the ePix platform for x-ray detectors and the current status of the ePix detectors: ePix100 for low noise applications, ePix10k for high dynamic range applications, and ePixS for spectroscopic applications. Then we will introduce the plans to match the ePix detectors with the requirements of currently plannedmore » high repetition rate FELs (mainly readout speed and energy range).« less
Endothelin-1 Inhibits the Epithelial Na+ Channel through βPix/14-3-3/Nedd4-2
Pavlov, Tengis S.; Chahdi, Ahmed; Ilatovskaya, Daria V.; Levchenko, Vladislav; Vandewalle, Alain; Pochynyuk, Oleh
2010-01-01
Epithelial Na+ channels (ENaCs) mediate sodium reabsorption in the cortical collecting duct (CCD), but the regulatory pathways that modulate the activity of these channels are incompletely understood. Here, we observed that endothelin-1 (ET-1) attenuates ENaC activity acutely by reducing the channel's open probability and chronically by decreasing the number of channels in the plasma membrane. To investigate whether β1Pix, a signaling protein activated by ET-1, mediates ENaC activity, we reconstituted ENaC in CHO cells with or without coexpressed β1Pix and found that β1Pix negatively regulates ENaC. Knockdown of βPix in native principal cells abolished the ET-1-induced decrease in ENaC channel number. Furthermore, we found that βPix does not decrease ENaC activity through its guanine nucleotide exchange factor (GEF) activity for Rac1 and Cdc42. Instead, coexpression of β1Pix mutant constructs revealed that β1Pix affects ENaC activity through binding 14-3-3 proteins. Coimmunoprecipitation experiments supported a physical interaction between β1Pix and 14-3-3β in cultured principal cells. Coexpression of 14-3-3β increased ENaC activity in CHO cells, but concomitant expression of β1Pix attenuated this increase. Recruitment of 14-3-3β by β1Pix impaired the interaction of 14-3-3β with the ubiquitin ligase Nedd4-2, thereby promoting ubiquitination and degradation of ENaC. Taken together, these results suggest that the inhibitory effects of chronic ET-1 on ENaC result from βPix interacting with the 14-3-3/Nedd4-2 pathway. PMID:20338996
PIXE analysis on Maya blue in Prehispanic and colonial mural paintings
NASA Astrophysics Data System (ADS)
Sánchez del Río, M.; Martinetto, P.; Solís, C.; Reyes-Valerio, C.
2006-08-01
Particle induced X-ray emission (PIXE) experiments have been carried out at the AGLAE facility (Paris) on several mural samples containing Maya blue from different Prehispanic archaeological sites (Cacaxtla, El Tajín, Tamuin, Santa Cecilia Acatitlán) and from several colonial convents in the Mexican plateau (Jiutepec, Totimehuacán, Tezontepec and Cuauhtinchán). The analysis of the concentration of several elements permitted to extract some information on the technique used for painting the mural, usually fresco. Principal component analysis permitted to classify the samples into groups. This grouping is discussed in relation to geographic and historic data.
PIXE analysis of mineral matter in thin sections of human lung
NASA Astrophysics Data System (ADS)
Annegarn, H. J.; Pillay, A. E.; Da Vies, J. C. A.; Faure, D.; Sellschop, J. P. F.
1988-12-01
It is postulated that insoluble mineral residues in the lungs of deceased miners may provide a quantitative measure of the integrated lifetime dust exposure. For epidemiological surveys rapid instrumental techniques are required to analyse representative samples of lung tissue. Particle-induced X-ray emission (PIXE) has been evaluated for analysis of microtomed slices of wax-embedded lung and lymph node (Hilar gland) tissue from deceased miners. The 50 μm slices, mounted on Mylar backings and placed in a He atmosphere, were irradiated using 3.2 MeV protons. PIXE analysis provided adequate sensitivity for key mineral elements including Si, Cr and Ti. The porous, nonuniform nature of lung tissue made it impossible to measure the tissue mass in the irradiated area, preventing the calculation of mass concentrations. Instead, biological sulphur was used as an internal standard, assuming that the fraction of S in soft, fat-free tissue is constant. Results are presented for lung and lymph node tissue from gold, chrome, copper, platinum and asbestos miners. Si mineral residues in lymph node tissue were found to be concentrated by a factor 50 relative to lung. Cr residues were clearly observed in the chrome miner's lung, but no excess of Cu was present in the copper miner's lung. There is evidence of preferential Si removal relative to Ti. Results warrant further development of PIXE for scanning of large numbers of lung samples prepared in the above manner.
Trace-Element Analysis by Use of PIXE Technique on Agricultural Products
NASA Astrophysics Data System (ADS)
Takagi, A.; Yokoyama, R.; Makisaka, K.; Kisamori, K.; Kuwada, Y.; Nishimura, D.; Matsumiya, R.; Fujita, Y.; Mihara, M.; Matsuta, K.; Fukuda, M.
2009-10-01
In order to examine whether a trace-element analysis by PIXE (Particle Induced X-ray Emission) gives a clue to identify production area of agricultural products, we carried out a study on soy beans as an example. In the present study, a proton beam at the energy of 2.3MeV was provided by Van de Graaff accelerator at Osaka University. We used a Ge detector with Be window to measure X-ray spectra. We prepared sample soy beans from China, Thailand, Taiwan, and 7 different areas in Japan. As a result of PIXE analysis, 5 elements, potassium, iron, zinc, arsenic and rubidium, have been identified. There are clear differences in relative amount of trace-elements between samples from different international regions. Chinese beans contain much more Rb than the others, while there are significant differences in Fe and Zn between beans of Thailand and Taiwan. There are relatively smaller differences among Japanese beans. This result shows that trace-elements bring us some practical information of the region where the product grown.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hichwa, B.P.; Pun, D.D.; Wang, D.
A multielemental analysis to determine the trace metal content of generic and name-brand aspirins and name-brand lipsticks was done via proton induced x-ray (PIXE) measurements. The Hope College PIXE system is described as well as the target preparation methods. The trace metal content of twelve brands of aspirin and aspirin substitutes and fourteen brands of lipstick are reported. Detection limits for most elements are in the range of 100 parts per billion (ppb) to 10 parts per million (ppm).
DeltaPhage—a novel helper phage for high-valence pIX phagemid display
Nilssen, Nicolay R.; Frigstad, Terje; Pollmann, Sylvie; Roos, Norbert; Bogen, Bjarne; Sandlie, Inger; Løset, Geir Å.
2012-01-01
Phage display has been instrumental in discovery of novel binding peptides and folded domains for the past two decades. We recently reported a novel pIX phagemid display system that is characterized by a strong preference for phagemid packaging combined with low display levels, two key features that support highly efficient affinity selection. However, high diversity in selected repertoires are intimately coupled to high display levels during initial selection rounds. To incorporate this additional feature into the pIX display system, we have developed a novel helper phage termed DeltaPhage that allows for high-valence display on pIX. This was obtained by inserting two amber mutations close to the pIX start codon, but after the pVII translational stop, conditionally inactivating the helper phage encoded pIX. Until now, the general notion has been that display on pIX is dependent on wild-type complementation, making high-valence display unachievable. However, we found that DeltaPhage does facilitate high-valence pIX display when used with a non-suppressor host. Here, we report a side-by-side comparison with pIII display, and we find that this novel helper phage complements existing pIX phagemid display systems to allow both low and high-valence display, making pIX display a complete and efficient alternative to existing pIII phagemid display systems. PMID:22539265
DeltaPhage--a novel helper phage for high-valence pIX phagemid display.
Nilssen, Nicolay R; Frigstad, Terje; Pollmann, Sylvie; Roos, Norbert; Bogen, Bjarne; Sandlie, Inger; Løset, Geir Å
2012-09-01
Phage display has been instrumental in discovery of novel binding peptides and folded domains for the past two decades. We recently reported a novel pIX phagemid display system that is characterized by a strong preference for phagemid packaging combined with low display levels, two key features that support highly efficient affinity selection. However, high diversity in selected repertoires are intimately coupled to high display levels during initial selection rounds. To incorporate this additional feature into the pIX display system, we have developed a novel helper phage termed DeltaPhage that allows for high-valence display on pIX. This was obtained by inserting two amber mutations close to the pIX start codon, but after the pVII translational stop, conditionally inactivating the helper phage encoded pIX. Until now, the general notion has been that display on pIX is dependent on wild-type complementation, making high-valence display unachievable. However, we found that DeltaPhage does facilitate high-valence pIX display when used with a non-suppressor host. Here, we report a side-by-side comparison with pIII display, and we find that this novel helper phage complements existing pIX phagemid display systems to allow both low and high-valence display, making pIX display a complete and efficient alternative to existing pIII phagemid display systems.
Elemental investigation of Syrian medicinal plants using PIXE analysis
NASA Astrophysics Data System (ADS)
Rihawy, M. S.; Bakraji, E. H.; Aref, S.; Shaban, R.
2010-09-01
Particle induced X-ray emission (PIXE) technique has been employed to perform elemental analysis of K, Ca, Mn, Fe, Cu, Zn, Br and Sr for Syrian medicinal plants used traditionally to enhance the body immunity. Plant samples were prepared in a simple dried base. The results were verified by comparing with those obtained from both IAEA-359 and IAEA-V10 reference materials. Relative standard deviations are mostly within ±5-10% suggest good precision. A correlation between the elemental content in each medicinal plant with its traditional remedial usage has been proposed. Both K and Ca are found to be the major elements in the samples. Fe, Mn and Zn have been detected in good levels in most of these plants clarifying their possible contribution to keep the body immune system in good condition. The contribution of the elements in these plants to the dietary recommended intakes (DRI) has been evaluated. Advantages and limitations of PIXE analytical technique in this investigation have been reviewed.
NASA Astrophysics Data System (ADS)
Huerta, L.; Contreras-Valadez, R.; Palacios-Mayorga, S.; Miranda, J.; Calva-Vasquez, G.
2002-04-01
The purpose of this work was to obtain the total elemental composition of agricultural soils irrigated with well water and wastewater. The studied area is located in the Valle del Mezquital in Hidalgo State, Mexico. The studied soils were collected, every two months during one year. Particle induced X-ray emission (PIXE), Rutherford backscattering spectrometry (RBS) and nuclear reaction analysis (NRA) were applied for elemental analysis. PIXE analyses gave elemental contents of major and trace elements (Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Br, Rb, Sr, Y, Zr, and Pb). Total concentrations of Na, Mg, C, N and O were obtained by RBS and NRA. PIXE analyses were carried out with 2 MeV proton beams, RBS with 2 MeV helium ions, while NRA was applied with a 1.2 MeV deuterium beam. Results indicated that heavy metal total concentrations exceed the critical soil total concentrations according to environmental regulations.
PIGE-PIXE analysis of human milk
NASA Astrophysics Data System (ADS)
Olabanji, S. O.; Buoso, M. C.; Ceccato, D.; Haque, A. M. I.; Cherubini, R.; Moschini, G.
1996-04-01
PIGE-PIXE nuclear techniques were employed for the determination of the elemental composition of human breast milk which is the main source of nutrients to babies in Nigeria. Samples were collected from 32 healthy lactating mothers from Obafemi Awolowo Teaching University Hospital, Ile-Ife, Nigeria. The samples were homogenized and immediately frozen, and then freeze-dried. Pellets were made using a Perkin Elmer instrument and its accessory the 13 mm die. PIGE measurements of light elements were performed using 3.5 MeV collimated protons from the 7 MV CN Van de Graaff accelerator of INFN, LNL, Legnaro (Padova) Italy while PIXE analysis was carried out using 1.8 MeV collimated proton beam from the 2.5 MV AN 2000 Van de Graaff accelerator of the same Institute. The results show the presence of important elements that are essential for growth and development of babies. We searched for certain toxic elements which include As, Cd, Hg, Pb, etc. because of their negative roles in enhancing infant mortality rates, but none of them was detected except Pb.
PIXE analysis of ancient Chinese Changsha porcelain
NASA Astrophysics Data System (ADS)
Lin, E. K.; Yu, Y. C.; Wang, C. W.; Liu, T. Y.; Wu, C. M.; Chen, K. M.; Lin, S. S.
1999-04-01
In this work, proton induced X-ray emission (PIXE) method was applied for the analysis of ancient Chinese Changsha porcelain produced in the Tang dynasty (AD 618-907). A collection of glazed potsherds was obtained in the complex of the famous kiln site at Tongguan, Changsha city, Hunan province. Studies of elemental composition were carried out on ten selected Changsha potsherds. Minor and trace elements such as Ti, Mn, Fe, Co, Cu, Rb, Sr, and Zr in the material of the porcelain glaze were determined. Variation of these elements from sample to sample was investigated. Details of results are presented and discussed.
RBS and PIXE analysis of chlorine contamination in ALD-Grown TiN films on silicon
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meersschaut, J.; Witters, T.; Kaeyhkoe, M.
2013-04-19
The performance, strengths and limitations of RBS and PIXE for the characterization of trace amounts of Cl in TiN thin films are critically compared. The chlorine atomic concentration in ALD grown TiN thin films on Si is determined for samples grown at temperatures ranging from 350 Degree-Sign C to 550 Degree-Sign C. We show that routine Rutherford backscattering spectrometry measurements (1.5 MeV He{sup +}) and PIXE measurements (1.5 MeV H{sup +}) on 20 nm thick TiN films allow one to determine the Cl content down to 0.3 at% with an absolute statistical accuracy reaching 0.03 at%. Possible improvements to pushmore » the sensitivity limit for both approaches are proposed.« less
NASA Astrophysics Data System (ADS)
Bradley, D. A.; Farquharson, M. J.; Gundogdu, O.; Al-Ebraheem, Alia; Che Ismail, Elna; Kaabar, W.; Bunk, O.; Pfeiffer, F.; Falkenberg, G.; Bailey, M.
2010-02-01
The investigations reported herein link tissue structure and elemental presence with issues of environmental health and disease, exemplified by uptake and storage of potentially toxic elements in the body, the osteoarthritic condition and malignancy in the breast and other soft tissues. Focus is placed on application of state-of-the-art ionizing radiation techniques, including, micro-synchrotron X-ray fluorescence (μ-SXRF) and particle-induced X-ray emission/Rutherford backscattering mapping (μ-PIXE/RBS), coherent small-angle X-ray scattering (cSAXS) and X-ray phase-contrast imaging, providing information on elemental make-up, the large-scale organisation of collagen and anatomical features of moderate and low atomic number media. For the particular situations under investigation, use of such facilities is allowing information to be obtained at an unprecedented level of detail, yielding new understanding of the affected tissues and the progression of disease.
de Viguerie, L; Beck, L; Salomon, J; Pichon, L; Walter, Ph
2009-10-01
Particle induced X-ray emission spectroscopy (PIXE) is now routinely used in the field of cultural heritage. Various setups have been developed to investigate the elemental composition of wood/canvas paintings or of cross-section samples. However, it is not possible to obtain information concerning the quantity of organic binder. Backscattering spectrometry (BS) can be a useful complementary method to overcome this limitation. In the case of paint layers, PIXE brings the elemental composition (major elements to traces) and the BS spectrum can give access to the proportion of pigment and binder. With the use of 3 MeV protons for PIXE and BS simultaneously, it was possible to perform quantitative analysis including C and O for which the non-Rutherford cross sections are intense. Furthermore, with the use of the same conditions for PIXE and BS, the experiment time and the potential damage by the ion beam were reduced. The results obtained with the external beam of the Accélérateur Grand Louvre pour l'Analyse Elementaire (AGLAE) facility on various test painting samples and on cross sections from Italian Renaissance masterpieces are shown. Simultaneous combination of PIXE and BS leads to a complete characterization of the paint layers: elemental composition and proportion of the organic binder have been determined and thus provide useful information about ancient oil painting recipes.
PIXE analysis of Thaumatococcus danielli in Osun State of Nigeria
NASA Astrophysics Data System (ADS)
Olabanji, S. O.; Osinkolu, G. A.; Pelemo, D. A.; Obiajunwa, E. I.; Oladele, A. T.
2014-01-01
Particle-induced X-ray emission (PIXE) technique was employed for the determination of elemental compositions of Thaumatococcus danielli (T. danielli) {Marantaceae} (Benn.) Benth [miraculous berry] in Osun State of Nigeria. The objective is to show the usefulness of T. danielli and especially the beneficial effects of the mineral concentrations from the leaves and fruits of T. danielli. The results show the detection of seventeen elements at different concentrations, and their beneficial effects to humans were discussed.
NASA Astrophysics Data System (ADS)
Vadrucci, M.; Bazzano, G.; Borgognoni, F.; Chiari, M.; Mazzinghi, A.; Picardi, L.; Ronsivalle, C.; Ruberto, C.; Taccetti, F.
2017-09-01
In the framework of the COBRA project, elemental analyses of cultural heritage objects based on the particle induced X-ray emission (PIXE) are planned in a collaboration between the APAM laboratory of ENEA-Frascati and the LABEC laboratory of INFN in Florence. With this aim a 3-7 MeV pulsed proton beam, driven by the injector of the protontherapy accelerator under construction for the TOP-IMPLART project, will be used to demonstrate the feasibility of the technique with a small-footprint pulsed accelerator to Italian small and medium enterprises interested in the composition analysis of ancient artifacts. The experimental set-up for PIXE analysis on the TOP-IMPLART machine consists of a modified assembly of the vertical beam line usually dedicated to radiobiology experiments: the beam produced by the injector (RFQ + DTL, a PL7 ACCSYSHITACHI model) is bent to 90° by a magnet, is collimated by a 300 μm aperture inserted in the end nozzle and extracted into ambient pressure by an exit window consisting of a Upilex foil 7.5 μm thick. The beam is pulsed with a variable pulse duration of 20-100 μs and a repetition rate variable from 10 to 100 Hz. The X-ray detection system is based on a Ketek Silicon Drift Detector (SDD) with 7 mm2 active area and 450 μm thickness, with a thin Beryllium entrance window (8 μm). The results of the calibration of this new PIXE set-up using thick target standards and of the analysis of the preliminary measurements on pigments are presented.
Elemental Levels Analyzed by PIXE in Florida Alligators
NASA Astrophysics Data System (ADS)
Kuharik, J. C.; Kravchenko, I. I.; Dunnam, F. E.; Van Rinsvelt, H. A.; Ross, J. P.
2003-08-01
Unusual and alarming mortality of alligators (Alligator mississippiensis) has been reported from Lake Griffin, Florida, where almost 400 dead alligators have been observed since 1997. In addition, the hatch rate for alligator eggs around Lake Griffin fell below 10% and remains low (30-45%) while the normal hatch rate is typically 80%. Standard diagnostic methods have been ineffective in determining the cause of the phenomenon. Many possibilities have been considered including pollutants, nutrition, and toxic algae. Particle Induced X-ray Emission (PIXE) analysis is highly suitable for investigating concentrations of a wide range of elements in animal tissue. Liver, kidney and spinal cord tissues from healthy and sick alligators have been analyzed by PIXE for elemental content. Initial results showed positive correlation between certain elements and neural impairment and morbidity of alligators in Lake Griffin, but have failed to prove significant.
PIXE study of Cuban quaternary paleoclimate geological samples and speleothems.
Montero, M E; Aspiazu, J; Pajón, J; Miranda, S; Moreno, E
2000-02-01
PIXE elemental analysis of sediments, speleothems, and other geological formations related to the karst of the Sierra de San Carlos is presented. The similarity of the elemental composition of the sediments studied, as well as the alluvial regime which created them, indicate their common origin at each location. The Sr/Ca concentration ratio of a stalactite indicates that the average atmospheric temperature 12,000 and 18,000 years B.P. was colder than that of 6000 years B.P.
NASA Astrophysics Data System (ADS)
Andres, J. M.; Hurd, R. W.; Van Rinsvelt, H. A.; Small, P. A.; Maenhaut, W.; Vandenhaute, J.
1987-03-01
Reye's syndrome is an acute illness in children manifested by encephalopathy, fatty infiltration of liver, and thymic hypoplasia. The syndrome usually occurs in a susceptible individual with a viral illness who has ingested salicylate. We previously investigated the metal status of children with this syndrome; serum Se and Cu levels were noted to be decreased. Chronic aspirin treatment of rats also produced alterations of serum Se, and liver Se and Cu. We now report our observations for an experimental model of Reye's syndrome. Analysis by PIXE of various metals in Se- and Cu-deficient mice exposed to virus and salicylate are discussed.
NASA Astrophysics Data System (ADS)
Beck, L.; Pichon, L.; Moignard, B.; Guillou, T.; Walter, P.
2011-12-01
For many years, ion beam analysis techniques have successfully been used to the study of cultural heritage objects. The chemical composition of work art is usually determined by PIXE, but in many cases, RBS and/or PIGE can provide useful complementary information. RBS gives information about the depth distribution and concentration in light elements, such as carbon and oxygen. In the past years, the experimental facilities at the AGLAE (Accélérateur Grand Louvre d'Analyse Élémentaire) accelerator has been progressively developed in order to apply simultaneously PIXE, PIGE and RBS under optimal conditions using an external beam. This combination is now routinely used for point analyses or mappings. In this contribution, we present several examples of applications: manufacturing technology of lustre-decorated ceramics and silver plating, control of altered or restored surfaces, and quantification of organic phase in painting and bone. The final conclusion is that the association of PIXE with RBS is very attractive for the investigation of cultural heritage objects, in particular of materials containing both mineral and organic components or possessing a multilayered structure. The first results of the production of monochromatic X-rays for radiography purposes by PIXE are also presented.
A Horizontal Multi-Purpose Microbeam System.
Xu, Y; Randers-Pehrson, G; Marino, S A; Garty, G; Harken, A; Brenner, D J
2018-04-21
A horizontal multi-purpose microbeam system with a single electrostatic quadruplet focusing lens has been developed at the Columbia University Radiological Research Accelerator Facility (RARAF). It is coupled with the RARAF 5.5 MV Singleton accelerator (High Voltage Engineering Europa, the Netherlands) and provides micrometer-size beam for single cell irradiation experiments. It is also used as the primary beam for a neutron microbeam and microPIXE (particle induced x-ray emission) experiment because of its high particle fluence. The optimization of this microbeam has been investigated with ray tracing simulations and the beam spot size has been verified by different measurements.
Micro-PIXE studies of Lupinus angustifolius L. after treatment of seeds with molybdenum
NASA Astrophysics Data System (ADS)
Przybylowicz, W. J.; Mesjasz-Przybylowicz, J.; Wouters, K.; Vlassak, K.; Combrink, N. J. J.
1997-02-01
An example of nuclear microprobe application in agriculture is presented. The NAC nuclear microprobe was used to determine quantitative elemental distribution of major, minor and trace elements in Lupinus angustifolius L. (Leguminosae) after treatment of seeds with molybdenum. Experiments were performed in order to establish safe concentration levels and sources of Mo in seed treatments. Elemental distributions in Mo-treated plants and in the non-treated control plants were studied in order to explain how Mo causes toxicity. Some specific regions of Mo and other main and trace elements enrichment were identified.
A horizontal multi-purpose microbeam system
NASA Astrophysics Data System (ADS)
Xu, Y.; Randers-Pehrson, G.; Marino, S. A.; Garty, G.; Harken, A.; Brenner, D. J.
2018-04-01
A horizontal multi-purpose microbeam system with a single electrostatic quadruplet focusing lens has been developed at the Columbia University Radiological Research Accelerator Facility (RARAF). It is coupled with the RARAF 5.5 MV Singleton accelerator (High Voltage Engineering Europa, the Netherlands) and provides micrometer-size beam for single cell irradiation experiments. It is also used as the primary beam for a neutron microbeam and microPIXE (particle induced x-ray emission) experiment because of its high particle fluence. The optimization of this microbeam has been investigated with ray tracing simulations and the beam spot size has been verified by different measurements.
Combined PIXE and X-ray SEM studies on time-resolved deposits of welding shop aerosols
NASA Astrophysics Data System (ADS)
Barfoot, K. M.; Mitchell, I. V.; Verheyen, F.; Babeliowsky, T.
1981-03-01
Time-resolved deposits of welding shop air particulates have been obtained using a streak sampling system. PIXE analysis of these deposits, using 2 MeV protons, typically revealed the presence of a large number of elements, with many in the range Z = 11-30. Strong variations, up to three orders of magnitude, in the concentrations of several elements such as Al, Si and Fe as well as Zn, Na, K and Ca were found. The 2 h sampling resolution normally used was found to be insufficient to follow the short pollution episodes that regularly occur in a welding shop environment and so sampling with a 20 min resolution was used. The variation of elemental concentrations for different sampling times together with information on the physical nature of these air particulates, determined with a scanning electron microscope (SEM) and Si(Li) X-ray detector attachment, are presented. This type of information together with that obtained from the PIXE analysis is of importance in industrial hygiene studies. The need to make corrections for partial filter clogging, based on air-flow rate monitoring, is discussed.
NASA Astrophysics Data System (ADS)
Biswas, S. K.; Khaliquzzaman, M.; Islam, M. M.; Khan, A. H.
1984-04-01
The validity of the use of a single multielement standard for mass calibration in thick-target external beam PIXE analysis of biological materials has been investigated. In this study, the NBS orchard leaf, SRM 1571, was used as the basic standard for trace element analysis in other biological materials. Using the present procedure, the concentrations of K, Ca, Mn, Fe, Ni, Cu, Zn, Br, Rb and Sr were determined in several NBS reference materials such as bovine liver, spinach, rice flour, etc., generally in 20 μC irradiations with 2.0 MeV protons. The analytical results are compared with certified values of the NBS as well as with other measurements and the sources of errors are discussed.
Characteristics of proton beams and secondary neutrons arising from two different beam nozzles
NASA Astrophysics Data System (ADS)
Choi, Yeon-Gyeong; Kim, Yu-Seok
2015-10-01
A tandem or a Van de Graaff accelerator with an energy of 3 MeV is typically used for Proton Induced X-ray Emission (PIXE) analysis. In this study, the beam line design used in the PIXE analysis, instead of the typical low-energy accelerator, was used to increase the production of isotopes from a 13-MeV cyclotron. For the PIXE analysis, the proton beam should be focused at the target through a nozzle after degrading the proton beams energy from 13 MeV to 3 MeV by using an energy degrader. Previous studies have been conducted to determine the most appropriate material for and the thickness of the energy degrader. From the energy distribution of the degraded proton beam and the neutron occurrence rate at the degrader, an aluminum nozzle of X thickness was determined to be the most appropriate nozzle construction. Neutrons are created by the collision of 3-MeV protons in the nozzle after passage through the energy degrader. In addition, a proton beam of sufficient intensity is required for a non-destructive PIXE analysis. Therefore, if nozzle design is to be optimized, the number of neutrons that arise from the collision of protons inside the nozzle, as well as the track direction of the generated secondary neutrons, must be considered, with the primary aim of ensuring that a sufficient number of protons pass through the nozzle as a direct beam. A number of laboratories are currently conducting research related to the design of nozzles used in accelerator fields, mostly medical fields. This paper presents a comparative analysis of two typical nozzle shapes in order to minimize the loss of protons and the generation of secondary neutrons. The neutron occurrence rate and the number of protons that pass through the nozzle were analyzed by using a Particle and Heavy Ion Transport code System (PHITS) program in order to identify the nozzle that generated the strongest proton beam.
Trace elements in lake sediments measured by the PIXE technique
NASA Astrophysics Data System (ADS)
Gatti, Luciana V.; Mozeto, Antônio A.; Artaxo, Paulo
1999-04-01
Lakes are ecosystems where there is a great potential of metal accumulation in sediments due to their depositional characteristics. Total concentration of trace elements was measured on a 50 cm long sediment core from the Infernão Lake, that is an oxbow lake of the Moji-Guaçu River basin, in the state of São Paulo, Brazil. Dating of the core shows up to 180 yrs old sediment layers. The use of the PIXE technique for elemental analysis avoids the traditional acid digestion procedure common in other techniques. The multielemental characteristic of PIXE allows a simultaneous determination of about 20 elements in the sediment samples, such as, Al, Si, P, S, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, Rb, Sr, Zr, Ba, and Pb. Average values for the elemental composition were found to be similar to the bulk crustal composition. The lake flooding pattern strongly influences the time series of the elemental profiles. Factor analysis of the elemental variability shows five factors. Two of the factors represent the mineralogical matrix, and others represent the organic component, a factor with lead, and another loaded with chromium. The mineralogical component consists of elements such as, Fe, Al, V, Ti, Mn, Ni, K, Zr, Sr, Cu and Zn. The variability of Si is explained by two distinct factors, because it is influenced by two different sources, aluminum-silicates and quartz, and the effect of inundation are different for each other. The organic matter is strongly associated with calcium, and also bounded with S, Zn, Cu and P. Lead and chromium appears as separated factors, although it is not clear the evidences for their anthropogenic origin. The techniques developed for sample preparation and PIXE analysis was proven as advantageous and provided very good reproducibility and accuracy.
XRF and micro-PIXE studies of inhomogeneity of ancient bronze and silver alloys
NASA Astrophysics Data System (ADS)
Vasilescu, A.; Constantinescu, B.; Stan, D.; Talmatchi, G.; Ceccato, D.
2017-09-01
New results regarding alloy composition and microstructure for a series of ancient bronze and silver items by X-ray Fluorescence and micro-Particle Induced X-ray Emission spectrometry were obtained in the framework of an extensive numismatic project (Scythian-type arrowheads, arrowhead-shaped monetary signs and wheel coins produced by Histria, 7th-4th century of BCE, and Dacian Radulesti-Hunedoara-type silver tetradrachms, 2nd-1st century of BCE). In Histria, warfare arrowheads were used for trade with Barbarian neighbors at first, then mechanically modified, next melted and cast as dedicated monetary signs, being, in the end, replaced by wheel coins. Three different types of alloys have been identified, and Cu-Mn and Cu-Pb segregation shown. In a blank for Radulesti-Hunedoara-type coins, Ag-(Cu+Pb) segregation has been demonstrated, suggesting an imperfectly alloyed silver-leaded bronze.
Micro-PIXE and micro-SR-XRF studies for Romanian archaeological gold identification
NASA Astrophysics Data System (ADS)
Constantinescu, B.
2009-04-01
For gold, trace elements are more significant for provenancing archaeological artifacts than the main components: Platinum Group Elements (PGE), Sn, Te, Sb, Hg, Pb, but also high melting point elements, such as Ta and Nb. Several small fragments of native Carpathian gold were studied using micro-PIXE technique at the AGLAE accelerator, Louvre Museum and at the Legnaro AN2000 microbeam facility, and using SR-XRF at BESSY synchrotron. The goal of the study was to identify the trace elements, especially Sn, Sb and Te. At BESSY, the SR-XRF measurements were performed in air by using a 34 keV beam to excite the characteristic X-lines in Sn-Sb-Te region. We found Sn to be present in placers from Valea Arieşului and Valea Pianului, Sb in primary gold from Zlatna, Ruda-Brad, Valea Morii, Runculeţ-Straja and Pb in primary gold from Brǎdişor-Brad, Zlatna, Runculeţ-Straja, Valea Morii, Muşariu-Brad. Ten native gold nuggets and several fragments of objects coming from Visigothic Pietroasa "The Golden Brood Hen with Its Chickens" hoard were analyzed using micro-PIXE technique at the AGLAE accelerator, Louvre Museum, Paris and at the Legnaro AN2000 microbeam facility. We found Te in primary gold from Brǎdişor-Brad, Muşariu-Brad (different samples from BESSY analyzed ones), and Roşia Montanǎ, Sb in primary gold at Bucium-Izbiţa. For Pietroasa hoard, we found Sn in the Oenochoe cup and small fibula, indicating that alluvial gold - probably from Anatolia (Pactolus river) - was used. We also detected Ta inclusions in the large fibula, indicating that Ural Mountains (the only region where Ta and Au minerals are together) gold was (at least partially) used. A spectacular application to nine Dacian gold bracelets (belonging to National History Museum of Romania) authentication is presented. These bracelets look like spirals and are based on the same artistic idea, are centred around the same theme. The number of spiral varies from 6 to 8. When uncoiled, some bracelets measure 2.30 m and others even 2.80 m. 4 of them weigh 1 kg each. At each end, the bracelets are decorated with 7 palm-leaf like ornaments. There are no two identical bracelets. The plate is continued with a so-called "protoma", a decorative element which looks like the head of an animal (a wolf, a snake or a dog). The Dacian bracelets were measured using XRF technique (Am-241 and Pu-238 sources and a portable Mo X-Ray tube used to control the homogeneity of the alloy for each bracelet). Compositions (Au-Ag-Cu) very similar to Brad region native gold (primary and placers), but different form bracelet to bracelet, were obtained. Differences in homogeneity, especially Cu content, for each bracelet were observed. Traces of Sn and Sb were also detected. Our conclusion: native gold (mainly alluvial - placers) from Brad region, primitive metallurgy (no refined gold).
Naturally occurring levels of elements in fishes as determined by PIXE and XRF methods
NASA Astrophysics Data System (ADS)
Tallandini, L.; Giacobini, F.; Turchetto, M.; Galassini, S.; Liu, Q. X.; Shao, H. R.; Moschini, G.; Moro, R.; Gialanella, G.; Ghermandi, G.; Cecchi, R.; Injuk, J.; Valković, V.
1989-04-01
Naturally occurring levels of S, Cl, K, Ca, Cr, Mn, Fe, Ni, Cu, Zn, As, Se, Br, Sb, Sr and Pb were measured in the gills, liver and muscles of fishes ( Zosterisessor ophiocephalus Pall) in the northwestern region of the Adriatic Sea. The overall performance of PIXE and XRF methods was tested by the analysis of standard reference materials. The mean concentration values for elements were calculated from the distribution of experimentally determined concentration values. The obtained data are discussed in the framework of metal metabolism and toxicology.
A high brightness proton injector for the Tandetron accelerator at Jožef Stefan Institute
NASA Astrophysics Data System (ADS)
Pelicon, Primož; Podaru, Nicolae C.; Vavpetič, Primož; Jeromel, Luka; Ogrinc Potocnik, Nina; Ondračka, Simon; Gottdang, Andreas; Mous, Dirk J. M.
2014-08-01
Jožef Stefan Institute recently commissioned a high brightness H- ion beam injection system for its existing tandem accelerator facility. Custom developed by High Voltage Engineering Europa, the multicusp ion source has been tuned to deliver at the entrance of the Tandetron™ accelerator H- ion beams with a measured brightness of 17.1 A m-2 rad-2 eV-1 at 170 μA, equivalent to an energy normalized beam emittance of 0.767 π mm mrad MeV1/2. Upgrading the accelerator facility with the new injection system provides two main advantages. First, the high brightness of the new ion source enables the reduction of object slit aperture and the reduction of acceptance angle at the nuclear microprobe, resulting in a reduced beam size at selected beam intensity, which significantly improves the probe resolution for micro-PIXE applications. Secondly, the upgrade strongly enhances the accelerator up-time since H and He beams are produced by independent ion sources, introducing a constant availability of 3He beam for fusion-related research with NRA. The ion beam particle losses and ion beam emittance growth imply that the aforementioned beam brightness is reduced by transport through the ion optical system. To obtain quantitative information on the available brightness at the high-energy side of the accelerator, the proton beam brightness is determined in the nuclear microprobe beamline. Based on the experience obtained during the first months of operation for micro-PIXE applications, further necessary steps are indicated to obtain optimal coupling of the new ion source with the accelerator to increase the normalized high-energy proton beam brightness at the JSI microprobe, currently at 14 A m-2 rad-2 eV-1, with the output current at 18% of its available maximum.
PIXE analysis of pottery from the recovery of a renaissance wreck
NASA Astrophysics Data System (ADS)
Zucchiatti, A.; Cardoni, F.; Prati, P.; Lucarelli, F.; Mandò, P. A.; Martino, G. P.
1998-03-01
Pottery recovered in a recent marine archaeology campaign in the sea of Liguria (Italy), from the so-called leudo di Varazze wreck, has been analysed by PIXE. By measuring the ratio of each observed element to iron, we have characterised the composition of the clay with particular attention to possible contamination due to the long immersion in the sea. The present results have been associated, in a discriminant analysis, to those obtained during a previous campaign on a set of furnace rejects coming from the towns of Savona and Albissola, to investigate the provenance of the crockery. Both are located a few miles west of the wreck and were important pottery centres.
Singh, Sudhir P; Vogel-Mikuš, Katarina; Vavpetič, Primož; Jeromel, Luka; Pelicon, Primož; Kumar, Jitendra; Tuli, Rakesh
2014-08-01
Wheat and its related genotypes show distinct distribution patterns for mineral nutrients in maternal and filial tissues in grains. X-ray-based imaging techniques are very informative to identify genotypes with contrasting tissue-specific localization of different elements. This can help in the selection of suitable genotypes for nutritional improvement of food grain crops. Understanding mineral localization in cereal grains is important for their nutritional improvement. Spatial distribution of mineral nutrients (Mg, P, S, K, Ca, Fe, Zn, Mn and Cu) was investigated between and within the maternal and filial tissues in grains of two wheat cultivars (Triticum aestivum Cv. WH291 and WL711), a landrace (T. aestivum L. IITR26) and a related wild species Aegilops kotschyi, using micro-proton-induced X-ray emission (µ-PIXE) and micro-X-ray fluorescence (µ-XRF). Aleurone and scutellum were major storage tissues for macro (P, K, Ca and Mg) as well as micro (Fe, Zn, Cu and Mn) nutrients. Distinct elemental distribution patterns were observed in each of the four genotypes. A. kotschyi, the wild relative of wheat and the landrace, T. aestivum L. IITR26, accumulated more Zn and Fe in scutellum and aleurone than the cultivated wheat varieties, WH291 and WL711. The landrace IITR26, accumulated far more S in grains, Mn in scutellum, aleurone and embryo region, Ca and Cu in aleurone and scutellum, and Mg, K and P in scutellum than the other genotypes. Unlike wheat, lower Mn and higher Fe, Cu and Zn concentrations were noticed in the pigment strand of A. kotschyi. Multivariate statistical analysis, performed on mineral distribution in major grain tissues (aleurone, scutellum, endosperm and embryo region) resolved the four genotypes into distinct clusters.
GIT1/βPIX signaling proteins and PAK1 kinase regulate microtubule nucleation.
Černohorská, Markéta; Sulimenko, Vadym; Hájková, Zuzana; Sulimenko, Tetyana; Sládková, Vladimíra; Vinopal, Stanislav; Dráberová, Eduarda; Dráber, Pavel
2016-06-01
Microtubule nucleation from γ-tubulin complexes, located at the centrosome, is an essential step in the formation of the microtubule cytoskeleton. However, the signaling mechanisms that regulate microtubule nucleation in interphase cells are largely unknown. In this study, we report that γ-tubulin is in complexes containing G protein-coupled receptor kinase-interacting protein 1 (GIT1), p21-activated kinase interacting exchange factor (βPIX), and p21 protein (Cdc42/Rac)-activated kinase 1 (PAK1) in various cell lines. Immunofluorescence microscopy revealed association of GIT1, βPIX and activated PAK1 with centrosomes. Microtubule regrowth experiments showed that depletion of βPIX stimulated microtubule nucleation, while depletion of GIT1 or PAK1 resulted in decreased nucleation in the interphase cells. These data were confirmed for GIT1 and βPIX by phenotypic rescue experiments, and counting of new microtubules emanating from centrosomes during the microtubule regrowth. The importance of PAK1 for microtubule nucleation was corroborated by the inhibition of its kinase activity with IPA-3 inhibitor. GIT1 with PAK1 thus represent positive regulators, and βPIX is a negative regulator of microtubule nucleation from the interphase centrosomes. The regulatory roles of GIT1, βPIX and PAK1 in microtubule nucleation correlated with recruitment of γ-tubulin to the centrosome. Furthermore, in vitro kinase assays showed that GIT1 and βPIX, but not γ-tubulin, serve as substrates for PAK1. Finally, direct interaction of γ-tubulin with the C-terminal domain of βPIX and the N-terminal domain of GIT1, which targets this protein to the centrosome, was determined by pull-down experiments. We propose that GIT1/βPIX signaling proteins with PAK1 kinase represent a novel regulatory mechanism of microtubule nucleation in interphase cells. Copyright © 2016 Elsevier B.V. All rights reserved.
MeV ion-beam analysis of optical data storage films
NASA Technical Reports Server (NTRS)
Leavitt, J. A.; Mcintyre, L. C., Jr.; Lin, Z.
1993-01-01
Our objectives are threefold: (1) to accurately characterize optical data storage films by MeV ion-beam analysis (IBA) for ODSC collaborators; (2) to develop new and/or improved analysis techniques; and (3) to expand the capabilities of the IBA facility itself. Using H-1(+), He-4(+), and N-15(++) ion beams in the 1.5 MeV to 10 MeV energy range from a 5.5 MV Van de Graaff accelerator, film thickness (in atoms/sq cm), stoichiometry, impurity concentration profiles, and crystalline structure were determined by Rutherford backscattering (RBS), high-energy backscattering, channeling, nuclear reaction analysis (NRA) and proton induced X-ray emission (PIXE). Most of these techniques are discussed in detail in the ODSC Annual Report (February 17, 1987), p. 74. The PIXE technique is briefly discussed in the ODSC Annual Report (March 15, 1991), p. 23.
Zhang, Xingwang; Wu, Danni; Lai, Jie; Lu, Yi; Yin, Zongning; Wu, Wei
2009-02-01
This work was aimed at investigating the feasibility of fluid-bed coating as a new method to prepare cyclodextrin inclusion complex. The inclusion complex of the model drug piroxicam (PIX) and 2-hydroxypropyl-beta-cyclodextrin (HPCD) in aqueous ethanol solution was sprayed and deposited onto the surface of the pellet substrate upon removal of the solvent. The coating process was fluent with high coating efficiency. Scanning electron microscopy revealed a coarse pellet surface, and a loosely packed coating structure. Significantly enhanced dissolution, over 90% at 5 min, was observed at stoichiometric PIX/HPCD molar ratio (1/1) and at a ratio with excessive HPCD (1/2). Differential scanning calorimetry and powder X-ray diffractometry confirmed absence of crystallinity of PIX at PIX/HPCD molar ratio of 1/1 and 1/2. Fourier transform-infrared spectrometry and Raman spectrometry revealed interaction between PIX and HPCD adding evidence on inclusion of PIX moieties into HPCD cavities. Solid-state (13)C NMR spectrometry indicated possible inclusion of PIX through the pyridine ring. It is concluded that fluid-bed coating has potential to be used as a new technique to prepare cyclodextrin inclusion complex.
Løset, Geir Åge; Roos, Norbert; Bogen, Bjarne; Sandlie, Inger
2011-02-24
Phage display is a leading technology for selection of binders with affinity for specific target molecules. Polypeptides are normally displayed as fusions to the major coat protein VIII (pVIII) or the minor coat protein III (pIII). Whereas pVIII display suffers from drawbacks such as heterogeneity in display levels and polypeptide fusion size limitations, toxicity and infection interference effects have been described for pIII display. Thus, display on other coat proteins such as pVII or pIX might be more attractive. Neither pVII nor pIX display have gained widespread use or been characterized in detail like pIII and pVIII display. Here we present a side-by-side comparison of display on pIII with display on pVII and pIX. Polypeptides of interest (POIs) are fused to pVII or pIX. The N-terminal periplasmic signal sequence, which is required for phage integration of pIII and pVIII and that has been added to pVII and pIX in earlier studies, is omitted altogether. Although the POI display level on pIII is higher than on pVII and pIX, affinity selection with pVII and pIX display libraries is shown to be particularly efficient. Display through pVII and/or pIX represent platforms with characteristics that differ from those of the pIII platform. We have explored this to increase the performance and expand the use of phage display. In the paper, we describe effective affinity selection of folded domains displayed on pVII or pIX. This makes both platforms more attractive alternatives to conventional pIII and pVIII display than they were before.
NASA Astrophysics Data System (ADS)
Bugoi, R.; Oanţă-Marghitu, R.; Calligaro, T.
2016-03-01
This paper reports the archaeometric investigations of 418 loose garnets from Pietroasa and Cluj-Someşeni treasures and Apahida II and III princely grave inventories (5th century AD). The chemical composition of the gems was determined by external beam micro-PIXE technique at the AGLAE accelerator of C2RMF, Paris, France. Complementary observations made by Optical Microscopy revealed details on the gemstones cutting and polishing and permitted to identify certain mineral inclusions. The compositional results evidenced several types of garnets from the pyralspite series, suggesting distinct provenances for these Early Medieval gems.
External-RBS, PIXE and NRA analysis for ancient swords
NASA Astrophysics Data System (ADS)
Santos, Hellen C.; Added, Nemitala; Silva, Tiago F.; Rodrigues, C. L.
2015-02-01
Elemental composition of the steel of two ancient swords (Japanese and Damascus from a private collection) was characterized using in air IBA techniques. Our results contribute for the understanding the processes of manufacturing (hammering and quenching) and surface treatments applied in these swords. The Particle Induced X-ray Emission (PIXE) measurements along the Damascus blade allowed to identify and to trace a superficial concentration profile for the elements such Cr, Mn, Fe, Ni, Cu, Zn and As, while results for the Japanese blade showed only the presence of iron. The carbon content on the surface was also investigated using a resonant region in the Elastic Backscattering Spectrometry (EBS) measurements and the results have shown a slightly difference between the surfaces under investigation. In order to investigate the nitrogen content on surface, that could explain the hardening process, we used Nuclear Reaction Analysis (NRA) and the results shown that nitrogen content was under our detection limit for the technique (0.3% in mass). The measurements of PIXE, NRA and EBS were taken using the external beam setup installed at Lamfi - São Paulo/Brazil, the latter being successfully implemented for the first time in this facility.
PIGE-PIXE analysis of chewing sticks of pharmacological importance
NASA Astrophysics Data System (ADS)
Olabanji, S. O.; Makanju, O. V.; Haque, A. M. I.; Buoso, M. C.; Ceccato, D.; Cherubini, R.; Moschini, G.
1996-06-01
PIGE and PIXE techniques were employed for the determination of the major, minor and trace elemental concentrations in chewing sticks of pharmacological importance namely: Butyrospermum paradoxum, Garcinia kola, Distemonanthus benthamianus, Bridelia ferruginea, Anogeissus leiocarpus, Terminalia glaucescens and Fagara rubescens, respectively. The concentration of fluorine which is very important for human dental enamel was specially determined using the 19F(p, p'γ) 19F reaction. For decades these chewing sticks when used alone without toothpastes have proven to be very efficient, effective and reliable in cleaning the teeth of many people particularly in Nigeria and some other countries in Africa. The teeth of users are usually very strong, clean, fresh and devoid of germs and caries. Even with the advent of modern toothpastes with special additions of fluorine, the use of these popular and efficient chewing sticks is still unabated. Many people including the elite use them solely, a few others combine their use with modern toothpastes and brush. Proton beams produced by the 7 MV CN and 2.5 MV AN 2000 Van de Graaff accelerators at INFN, Laboratori Nazionali di Legnaro (LNL), Padova, Italy were used for the PIGE and PIXE analysis, respectively. Results of this novel study are presented and discussed.
Topographic PIXE analysis of platinum levels in kidney slices from CIS-platin treated patients
NASA Astrophysics Data System (ADS)
Dikhoff, T. G. M. H.; Van Der Heide, J. A.; McVie, J. G.
1985-05-01
Concentrations of platinum and several other trace elements have been measured exploiting a 50 × 50 μ proton beam for PIXE analysis. The thickness of a selective germanium absorber for the spectral resolution of platinum L β and selenium K α peaks optimized, taking into account the fluorescent X-rays excited in the absorber material. The measurements have been performed in the framework of a project on the assessment of the toxicity of cytostatic platinum compounds. The lateral distributions of platinum in human kidneys and in dog tissues were measured. The highest concentrations of platinum were seen in arterial walls, followed by glomeruli and tubules. Chronic kidney damage may be correlated to this pattern of retention.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kelly, R.F.; Kravchenko, I.I.; Kuharik, J.C.
Widespread use of chromated copper arsenate (CCA) as a wood preservative has led to increasing public concern regarding possible toxic contamination of areas surrounding CCA-treated structures, e.g., decks, playground equipment, etc. Appreciable leaching of arsenic, chromium, and copper into soils adjacent to such structures has been demonstrated via standard techniques of analytical chemistry. The advantages of PIXE [rapid analysis, quick sample turnover, possible lower cost] suggest its application to this area of interest. PIXE studies in our laboratory of CCA-contaminated soil samples show good agreement with previous analyses of As, Cu, Cr, and other heavy-elemental content, with some variability inmore » diffusion rates.« less
NASA Astrophysics Data System (ADS)
Bugoi, Roxana; Talmaţchi, Cristina; Haitǎ, Constantin; Ceccato, Daniele
2018-02-01
An assemblage of 58 ceramic shards discovered in archaeological excavations at Oltina, Romania, dated to the 10th-11th century CE, was subjected to archaeometric investigations in order to reveal the raw materials and manufacturing techniques employed by the potters from the Lower Danube zone during the Byzantine ruling. The initial grouping of the shards according to stylistic criteria was refined by the subsequent petrographic study. Optical Microscopy (OM) detailed the general mineralogy and the pottery fabric, i.e. the textural characteristics, porosity and microstructure, surface treatments and firing. The PIXE analyses of potteries performed at AN2000 accelerator of LNL, INFN, Italy led to the identification of the chemical composition of the ceramic shards. The Hierarchical Cluster Analysis of the PIXE data evidenced several categories of shards with distinct compositional signatures, the main division being the one separating the ceramic fragments made of kaolinitic clays from the rest of the Oltina potteries.
Løset, Geir Åge; Roos, Norbert; Bogen, Bjarne; Sandlie, Inger
2011-01-01
Background Phage display is a leading technology for selection of binders with affinity for specific target molecules. Polypeptides are normally displayed as fusions to the major coat protein VIII (pVIII) or the minor coat protein III (pIII). Whereas pVIII display suffers from drawbacks such as heterogeneity in display levels and polypeptide fusion size limitations, toxicity and infection interference effects have been described for pIII display. Thus, display on other coat proteins such as pVII or pIX might be more attractive. Neither pVII nor pIX display have gained widespread use or been characterized in detail like pIII and pVIII display. Methodology/Principal Findings Here we present a side-by-side comparison of display on pIII with display on pVII and pIX. Polypeptides of interest (POIs) are fused to pVII or pIX. The N-terminal periplasmic signal sequence, which is required for phage integration of pIII and pVIII and that has been added to pVII and pIX in earlier studies, is omitted altogether. Although the POI display level on pIII is higher than on pVII and pIX, affinity selection with pVII and pIX display libraries is shown to be particularly efficient. Conclusions/Significance Display through pVII and/or pIX represent platforms with characteristics that differ from those of the pIII platform. We have explored this to increase the performance and expand the use of phage display. In the paper, we describe effective affinity selection of folded domains displayed on pVII or pIX. This makes both platforms more attractive alternatives to conventional pIII and pVIII display than they were before. PMID:21390283
The GIT–PIX complexes regulate the chemotactic response of rat basophilic leukaemia cells
Gavina, Manuela; Za, Lorena; Molteni, Raffaella; Pardi, Ruggero; Curtis, Ivan de
2009-01-01
Background information. Cell motility entails the reorganization of the cytoskeleton and membrane trafficking for effective protrusion. The GIT–PIX protein complexes are involved in the regulation of cell motility and adhesion and in the endocytic traffic of members of the family of G-protein-coupled receptors. We have investigated the function of the endogenous GIT complexes in the regulation of cell motility stimulated by fMLP (formyl-Met-Leu-Phe) peptide, in a rat basophilic leukaemia RBL-2H3 cell line stably expressing an HA (haemagglutinin)-tagged receptor for the fMLP peptide. Results. Our analysis shows that RBL cells stably transfected with the chemoattractant receptor expressed both GIT1–PIX and GIT2–PIX endogenous complexes. We have used silencing of the different members of the complex by small interfering RNAs to study the effects on a number of events linked to agonist-induced cell migration. We found that cell adhesion was not affected by depletion of any of the proteins of the GIT complex, whereas agonist-enhanced cell spreading was inhibited. Analysis of agonist-stimulated haptotactic cell migration indicated a specific positive effect of GIT1 depletion on trans-well migration. The internalization of the formyl-peptide receptor was also inhibited by depletion of GIT1 and GIT2. The effects of the GIT complexes on trafficking of the receptors was confirmed by an antibody-enhanced agonist-induced internalization assay, showing that depletion of PIX, GIT1 or GIT2 protein caused decreased perinuclear accumulation of internalized receptors. Conclusions. Our results show that endogenous GIT complexes are involved in the regulation of chemoattractant-induced cell motility and receptor trafficking, and support previous findings indicating an important function of the GIT complexes in the regulation of different G-protein-coupled receptors. Our results also indicate that endogenous GIT1 and GIT2 regulate distinct subsets of agonist-induced responses and suggest a possible functional link between the control of receptor trafficking and the regulation of cell motility by GIT proteins. PMID:19912111
Shibata, Akihiro C E; Chen, Limin H; Nagai, Rie; Ishidate, Fumiyoshi; Chadda, Rahul; Miwa, Yoshihiro; Naruse, Keiji; Shirai, Yuki M; Fujiwara, Takahiro K; Kusumi, Akihiro
2013-01-01
The focal adhesion (FA) is an integrin-based structure built in/on the plasma membrane (PM), linking the extracellular matrix to the actin stress-fibers, working as cell migration scaffolds. Previously, we proposed the archipelago architecture of the FA, in which FA largely consists of fluid membrane, dotted with small islands accumulating FA proteins: membrane molecules enter the inter-island channels in the FA zone rather freely, and the integrins in the FA-protein islands rapidly exchanges with those in the bulk membrane. Here, we examined how Rac1, a small G-protein regulating FA formation, and its activators αPIX and βPIX, are recruited to the FA zones. PIX molecules are recruited from the cytoplasm to the FA zones directly. In contrast, majorities of Rac1 molecules first arrive from the cytoplasm on the general inner PM surface, and then enter the FA zones via lateral diffusion on the PM, which is possible due to rapid Rac1 diffusion even within the FA zones, slowed only by a factor of two to four compared with that outside. The constitutively-active Rac1 mutant exhibited temporary and all-time immobilizations in the FA zone, suggesting that upon PIX-induced Rac1 activation at the FA-protein islands, Rac1 tends to be immobilized at the FA-protein islands. © 2013 Wiley Periodicals, Inc PMID:23341328
NASA Astrophysics Data System (ADS)
Li, Ke; Chen, Jianping; Sofia, Giulia; Tarolli, Paolo
2014-05-01
Moon surface features have great significance in understanding and reconstructing the lunar geological evolution. Linear structures like rilles and ridges are closely related to the internal forced tectonic movement. The craters widely distributed on the moon are also the key research targets for external forced geological evolution. The extremely rare availability of samples and the difficulty for field works make remote sensing the most important approach for planetary studies. New and advanced lunar probes launched by China, U.S., Japan and India provide nowadays a lot of high-quality data, especially in the form of high-resolution Digital Terrain Models (DTMs), bringing new opportunities and challenges for feature extraction on the moon. The aim of this study is to recognize and extract lunar features using geomorphometric analysis based on multi-scale parameters and multi-resolution DTMs. The considered digital datasets include CE1-LAM (Chang'E One, Laser AltiMeter) data with resolution of 500m/pix, LRO-WAC (Lunar Reconnaissance Orbiter, Wide Angle Camera) data with resolution of 100m/pix, LRO-LOLA (Lunar Reconnaissance Orbiter, Lunar Orbiter Laser Altimeter) data with resolution of 60m/pix, and LRO-NAC (Lunar Reconnaissance Orbiter, Narrow Angle Camera) data with resolution of 2-5m/pix. We considered surface derivatives to recognize the linear structures including Rilles and Ridges. Different window scales and thresholds for are considered for feature extraction. We also calculated the roughness index to identify the erosion/deposits area within craters. The results underline the suitability of the adopted methods for feature recognition on the moon surface. The roughness index is found to be a useful tool to distinguish new craters, with higher roughness, from the old craters, which present a smooth and less rough surface.
NASA Astrophysics Data System (ADS)
Chalise, Sajju; Conlan, Skye; Porat, Zachary; Labrake, Scott; Vineyard, Michael
2017-09-01
The Union College Ion-Beam Analysis Lab's 1.1 MV tandem Pelletron accelerator is used to determine the presence of heavy trace metals in Queens, NY between Astoria Park and 3.5 miles south to Gantry State Park. A PIXE analysis was performed on 0.5 g pelletized soil samples with a 2.2 MeV proton beam. The results show the presence of elements ranging from Ti to Pb with the concentration of Pb in Astoria Park (2200 +/-200 ppm) approximately ten times that of the Gantry State Park. We hypothesize that the high lead concentration at Astoria Park is due to the nearby Hell Gate Bridge, painted in 1916 with lead based paint, then sandblasted and repainted in the '90s. If the lead is from the repair of the bridge, then we should see the concentration decrease as we go further from the bridge. To test this, soil samples were collected and analyzed from seven different locations north and south of the bridge. The concentrations of lead decreased drastically within a 500 m radius and were approximately constant at greater distances. More soil samples need to be collected within the 500 m radius from bridge to identify the potential source of Pb. We will describe the experimental procedure, the PIXE analysis of soil samples, and present preliminary results on the distribution of heavy trace metals.
NASA Astrophysics Data System (ADS)
van der Graaf, Harry
2009-07-01
The Gossip detector, being a GridPix TPC equipped with a thin layer of gas, is a promising alternative for Si tracking detectors. In addition, GridPix would be an interesting way to read out the gaseous phase volume of bi-phase Liquid Xe cryostats of v-less double beta decay and rare event (i.e. WIMP) search experiments.
Further results from PIXE analysis of inks in Galileo's notes on motion
NASA Astrophysics Data System (ADS)
Del Carmine, P.; Giuntini, L.; Hooper, W.; Lucarelli, F.; Mandò, P. A.
1996-06-01
We have recently analysed the inks in some of the folios of Vol. 72 of Manoscritti galileiani, kept at the Biblioteca Nazionale Centrale di Firenze, which contains a collection of loose handwritten sheets containing undated notes, data from experiments and propositions on the problems of motion from different periods of Galileo's life. This paper reports specific results obtained from the analysis of some of these propositions, which allowed to make a contribution to their chronological attribution and therefore to the solution of some historical controversies. Even in the case where the "absolute" chronological attributions could not be made on the basis of comparison with dated documents, the PIXE results provided useful information to deny or confirm the hypothesis that different propositions were written in the same or in different periods.
Ion beam analyses of radionuclide migration in heterogeneous rocks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alonso, Ursula; Missana, Tiziana; Garcia-Gutierrez, Miguel
2013-07-18
The migration of radionuclides (RN) in the environment is a topic of general interest, for its implications on public health, and it is an issue for the long-term safety studies of deep geological repositories (DGR) for high-level radioactive waste. The role played by colloids on RN migration is also of great concern. Diffusion and sorption are fundamental mechanisms controlling RN migration in rocks and many experimental approaches are applied to determine transport parameters for low sorbing RN in homogeneous rocks. However, it is difficult to obtain relevant data for high sorbing RN or colloids, for which diffusion lengths are extremelymore » short, or within heterogeneous rocks, where transport might be different in different minerals. The ion beam techniques Rutherford Backscattering Spectrometry (RBS) and micro-Particle Induced X-Ray Emission ({mu}PIXE), rarely applied in the field, were selected for their micro-analytical potential to study RN diffusion and surface retention within heterogeneous rocks. Main achievements obtained during last 12 years are highlighted.« less
A method to visualize transdermal nickel permeation in mouse skin using a nickel allergy patch
Sugiyama, Tomoko; Uo, Motohiro; Wada, Takahiro; Hongo, Toshio; Omagari, Daisuke; Komiyama, Kazuo; Oikawa, Masakazu; Kusama, Mikio; Mori, Yoshiyuki
2015-01-01
Metal patch test is often used in clinical settings when metal-induced contact dermatitis is suspected. However, the transdermal permeation behavior of metal ions from the patch test remains unclear. Current patch tests using high concentrations of metal salt solutions have some side effects, e.g. acute skin reactions to high concentrations of metal salt. To resolve these, estimating metal ion transdermal permeation is wished. In this study, synchrotron radiation X-ray fluorescence (SR-XRF) and micro-focused particle-induced X-ray emission (micro-PIXE) were used to visualize the time-dependent Ni permeation in mouse skin. The cross-sectional diffusion of Ni was visualized in a time-dependent manner. Our results indicate that maximum Ni permeation occurs after 24 h of patch treatment, and the permeated Ni content was high in the epidermis and spread into the dermis beyond the basal layer. This method may be useful to determine the appropriate solution concentration and duration of administration for the patch test. PMID:26484550
Proton-Induced X-Ray Emission Analysis of Crematorium Emissions
NASA Astrophysics Data System (ADS)
Ali, Salina; Nadareski, Benjamin; Safiq, Alexandrea; Smith, Jeremy; Yoskowitz, Josh; Labrake, Scott; Vineyard, Michael
2013-10-01
There has been considerable concern in recent years about possible mercury emissions from crematoria. We have performed a particle-induced X-ray emission (PIXE) analysis of atmospheric aerosol samples collected on the roof of the crematorium at Vale Cemetery in Schenectady, NY, to address this concern. The samples were collected with a nine-stage cascade impactor that separates the particulate matter according to particle size. The aerosol samples were bombarded with 2.2-MeV protons from the Union College 1.1-MV Pelletron Accelerator. The emitted X-rays were detected with a silicon drift detector and the X-ray energy spectra were analyzed using GUPIX software to determine the elemental concentrations. We measured significant concentrations of sulfur, phosphorus, potassium, calcium, and iron, but essentially no mercury. The lower limit of detection for mercury in this experiment was approximately 0.2 ng/m3. We will describe the experimental procedure, discuss the PIXE analysis, and present preliminary results.
NASA Astrophysics Data System (ADS)
Swann, C. P.; Caspi, Sara; Carlson, Janice
1999-04-01
Much has been said recently concerning the Moche culture of Peru (100 B.C. to 700 A.D. ) which preceded the more widely known Inca society. Since there was no written language, what is known about the Moche people has been through the artifacts produced, their design and craftsmanship. This study concerns the PIXE analysis of the matrix and the red and white surface patterns of six stirrup handled earthenware vessels. The results suggest different techniques were applied for producing the coloring and surface designs and that a common source of clays was not used in the construction.
Large Area Coverage of a TPC Endcap with GridPix Detectors
NASA Astrophysics Data System (ADS)
Kaminski, Jochen
2018-02-01
The Large Prototype TPC at DESY, Hamburg, was built by the LCTPC collaboration as a testbed for new readout technologies of Time Projection Chambers. Up to seven modules of about 400 cm2 each can be placed in the endcap. Three of these modules were equipped with a total of 160 GridPix detectors. This is a combination of a highly pixelated readout ASIC and a Micromegas built on top. GridPix detectors have a very high efficiency of detecting primary electrons, which leads to excellent spatial and energy resolutions. For the first time a large number of GridPix detectors has been operated and long segments of tracks have been recorded with excellent precision.
The PIX-2 experiment: An overview
NASA Astrophysics Data System (ADS)
Purvis, C. K.
1985-03-01
The second Plasma Interactions Experiment (PIX-2) was launched in January 1983 as a piggyback on the second stage of the Delta launch vehicle that carried IRAS into orbit. Placed in a 870 km circular polar orbit, it returned 18 hrs of data on the plasma current collection and arcing behavior of solar arrays biased to +/-1000 V in steps. The four 500 sq cm solar array segments were biased singly and in combinations. In addition to the array segments PIX-2 carried a Sun sensor, a Langmuir probe to measure electron currents, and a hot-wire filament electron emitter to control vehicle potential during positive array bias sequences. The PIX-2 experiment is reviewed from program and operational perspectives.
CdTe detector based PIXE mapping of geological samples
NASA Astrophysics Data System (ADS)
Chaves, P. C.; Taborda, A.; de Oliveira, D. P. S.; Reis, M. A.
2014-01-01
A sample collected from a borehole drilled approximately 10 km ESE of Bragança, Trás-os-Montes, was analysed by standard and high energy PIXE at both CTN (previous ITN) PIXE setups. The sample is a fine-grained metapyroxenite grading to coarse-grained in the base with disseminated sulphides and fine veinlets of pyrrhotite and pyrite. Matrix composition was obtained at the standard PIXE setup using a 1.25 MeV H+ beam at three different spots. Medium and high Z elemental concentrations were then determined using the DT2fit and DT2simul codes (Reis et al., 2008, 2013 [1,2]), on the spectra obtained in the High Resolution and High Energy (HRHE)-PIXE setup (Chaves et al., 2013 [3]) by irradiation of the sample with a 3.8 MeV proton beam provided by the CTN 3 MV Tandetron accelerator. In this paper we present results, discuss detection limits of the method and the added value of the use of the CdTe detector in this context.
NASA Astrophysics Data System (ADS)
Caragiulo, P.; Dragone, A.; Markovic, B.; Herbst, R.; Nishimura, K.; Reese, B.; Herrmann, S.; Hart, P.; Blaj, G.; Segal, J.; Tomada, A.; Hasi, J.; Carini, G.; Kenney, C.; Haller, G.
2014-09-01
ePix100 is the first variant of a novel class of integrating pixel ASICs architectures optimized for the processing of signals in second generation LINAC Coherent Light Source (LCLS) X-Ray cameras. ePix100 is optimized for ultra-low noise application requiring high spatial resolution. ePix ASICs are based on a common platform composed of a random access analog matrix of pixel with global shutter, fast parallel column readout, and dedicated sigma-delta analog to digital converters per column. The ePix100 variant has 50μmx50μm pixels arranged in a 352x384 matrix, a resolution of 50e- r.m.s. and a signal range of 35fC (100 photons at 8keV). In its final version it will be able to sustain a frame rate of 1kHz. A first prototype has been fabricated and characterized and the measurement results are reported here.
ePix: a class of architectures for second generation LCLS cameras
Dragone, A.; Caragiulo, P.; Markovic, B.; ...
2014-03-31
ePix is a novel class of ASIC architectures, based on a common platform, optimized to build modular scalable detectors for LCLS. The platform architecture is composed of a random access analog matrix of pixel with global shutter, fast parallel column readout, and dedicated sigma-delta analog-to-digital converters per column. It also implements a dedicated control interface and all the required support electronics to perform configuration, calibration and readout of the matrix. Based on this platform a class of front-end ASICs and several camera modules, meeting different requirements, can be developed by designing specific pixel architectures. This approach reduces development time andmore » expands the possibility of integration of detector modules with different size, shape or functionality in the same camera. The ePix platform is currently under development together with the first two integrating pixel architectures: ePix100 dedicated to ultra low noise applications and ePix10k for high dynamic range applications.« less
Background considerations in the analysis of PIXE spectra by Artificial Neural Systems.
NASA Astrophysics Data System (ADS)
Correa, R.; Morales, J. R.; Requena, I.; Miranda, J.; Barrera, V. A.
2016-05-01
In order to study the importance of background in PIXE spectra to determine elemental concentrations in atmospheric aerosols using artificial neural systems ANS, two independently trained ANS were constructed, one which considered as input the net number of counts in the peak, and another which included the background. In the training and validation phases thirty eight spectra of aerosols collected in Santiago, Chile, were used. In both cases the elemental concentration values were similar. This fact was due to the intrinsic characteristic of ANS operating with normalized values of the net and total number of counts under the peaks, something that was verified in the analysis of 172 spectra obtained from aerosols collected in Mexico city. Therefore, networks operating under the mode which include background can reduce time and cost when dealing with large number of samples.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ryan, C.G.; De Geronimo, G.; Kirkham, R.
2009-11-13
The fundamental parameter method for quantitative SXRF and PIXE analysis and imaging using the dynamic analysis method is extended to model the changing X-ray yields and detector sensitivity with angle across large detector arrays. The method is implemented in the GeoPIXE software and applied to cope with the large solid-angle of the new Maia 384 detector array and its 96 detector prototype developed by CSIRO and BNL for SXRF imaging applications at the Australian and NSLS synchrotrons. Peak-to-background is controlled by mitigating charge-sharing between detectors through careful optimization of a patterned molybdenum absorber mask. A geological application demonstrates the capabilitymore » of the method to produce high definition elemental images up to {approx}100 M pixels in size.« less
NASA Astrophysics Data System (ADS)
Olabanji, S. O.; Ige, O. A.; Mazzoli, C.; Ceccato, D.; Akintunde, J. A.; De Poli, M.; Moschini, G.
2005-10-01
For the first time, the complementary accelerator-based analytical technique of PIXE and electron microprobe analysis (EMPA) were employed for the characterization of some Nigeria's natural minerals namely fluorite, tourmaline and topaz. These minerals occur in different areas in Nigeria. The minerals are mainly used as gemstones and for other scientific and technological applications and therefore are very important. There is need to characterize them to know the quality of these gemstones and update the geochemical data on them geared towards useful applications. PIXE analysis was carried out using the 1.8 MeV collimated proton beam from the 2.5 MV AN 2000 Van de Graaff accelerator at INFN, LNL, Legnaro, Padova, Italy. The novel results which show many elements at different concentrations in these minerals are presented and discussed.
Mesibov, Robert
2014-01-01
Abstract Dicranogonus pix Jeekel, 1982 occurs in Victoria and Tasmania, Australia, including the islands in eastern Bass Strait between the two States. There is only slight gonopod variation across this range, but Dicranogonus pix populations with and without paranota are separated in Bass Strait by the ca 50 km-wide gap between the Kent and Furneaux Groups of islands. PMID:25493065
Jones, Neil P; Katan, Matilda
2007-08-01
The significance of multiprotein signaling complexes in cell motility is becoming increasingly important. We have previously shown that phospholipase Cgamma1 (PLCgamma1) is critical for integrin-mediated cell spreading and motility (N. Jones et al., J. Cell Sci. 118:2695-2706, 2005). In the current study we show that, on a basement membrane-type matrix, PLCgamma1 associates with the adaptor protein GIT1 and the Rac1/Cdc42 guanine exchange factor beta-Pix; GIT1 and beta-Pix form tight complexes independently of PLCgamma1. The association of PLCgamma1 with the complex requires both GIT1 and beta-Pix and the specific array region (gammaSA) of PLCgamma1. Mutations of PLCgamma1 within the gammaSA region reveal that association with this complex is essential for the phosphorylation of PLCgamma1 and the progression to an elongated morphology after integrin engagement. Short interfering RNA (siRNA) depletion of either beta-Pix or GIT1 inhibited cell spreading in a fashion similar to that seen with siRNA against PLCgamma1. Furthermore, siRNA depletion of PLCgamma1, beta-Pix, or GIT1 inhibited Cdc42 and Rac1 activation, while constitutively active forms of Cdc42 or Rac1, but not RhoA, were able to rescue the elongation of these cells. Signaling of the PLCgamma1/GIT1/beta-Pix complex to Cdc42/Rac1 was found to involve the activation of calpains, calcium-dependent proteases. Therefore, we propose that the association of PLCgamma1 with complexes containing GIT1 and beta-Pix is essential for its role in integrin-mediated cell spreading and motility. As a component of this complex, PLCgamma1 is also involved in the activation of Cdc42 and Rac1.
NASA Astrophysics Data System (ADS)
Ontalba Salamanca, M. Á.; Gómez-Tubío, B.; Ortega-Feliu, I.; Respaldiza, M. Á.; Luisa de la Bandera, M.; Ovejero Zappino, G.; Bouzas, A.; Gómez-Morón, A.
2006-08-01
This paper presents the study of a set of Punic gold items (400 B.C.), from the Museum of Cádiz (Spain). An external beam set-up has been employed for the absolutely non-destructive analysis of the objects. PIXE spectrometry has been performed in order to characterize the metallic alloys and the manufacturing techniques. Compositional differences have been found and soldering procedures have been identified. By comparison with the rings and other coetaneous jewellery, the presence of palladium in the bulk alloy of the earrings can be pointed out. The geographical provenance of the palladium-bearing gold is discussed based on geological and archaeological considerations.
NASA Astrophysics Data System (ADS)
2001-01-01
Last year saw very good progress at ESO's Paranal Observatory , the site of the Very Large Telescope (VLT). The third and fourth 8.2-m Unit Telescopes, MELIPAL and YEPUN had "First Light" (cf. PR 01/00 and PR 18/00 ), while the first two, ANTU and KUEYEN , were busy collecting first-class data for hundreds of astronomers. Meanwhile, work continued towards the next phase of the VLT project, the combination of the telescopes into the VLT Interferometer. The test instrument, VINCI (cf. PR 22/00 ) is now being installed in the VLTI Laboratory at the centre of the observing platform on the top of Paranal. Below is a new collection of video sequences and photos that illustrate the latest developments at the Paranal Observatory. The were obtained by the EPR Video Team in December 2000. The photos are available in different formats, including "high-resolution" that is suitable for reproduction purposes. A related ESO Video News Reel for professional broadcasters will soon become available and will be announced via the usual channels. Overview Paranal Observatory (Dec. 2000) Video Clip 02a/01 [MPEG - 4.5Mb] ESO PR Video Clip 02a/01 "Paranal Observatory (December 2000)" (4875 frames/3:15 min) [MPEG Video+Audio; 160x120 pix; 4.5Mb] [MPEG Video+Audio; 320x240 pix; 13.5 Mb] [RealMedia; streaming; 34kps] [RealMedia; streaming; 200kps] ESO Video Clip 02a/01 shows some of the construction activities at the Paranal Observatory in December 2000, beginning with a general view of the site. Then follow views of the Residencia , a building that has been designed by Architects Auer and Weber in Munich - it integrates very well into the desert, creating a welcome recreational site for staff and visitors in this harsh environment. The next scenes focus on the "stations" for the auxiliary telescopes for the VLTI and the installation of two delay lines in the 140-m long underground tunnel. The following part of the video clip shows the start-up of the excavation work for the 2.6-m VLT Survey Telescope (VST) as well as the location known as the "NTT Peak", now under consideration for the installation of the 4-m VISTA telescope. The last images are from to the second 8.2-m Unit Telescope, KUEYEN, that has been in full use by the astronomers with the UVES and FORS2 instruments since April 2000. ESO PR Photo 04a/01 ESO PR Photo 04a/01 [Preview - JPEG: 466 x 400 pix - 58k] [Normal - JPEG: 931 x 800 pix - 688k] [Hires - JPEG: 3000 x 2577 pix - 7.6M] Caption : PR Photo 04a/01 shows an afternoon view from the Paranal summit towards East, with the Base Camp and the new Residencia on the slope to the right, above the valley in the shadow of the mountain. ESO PR Photo 04b/01 ESO PR Photo 04b/01 [Preview - JPEG: 791 x 400 pix - 89k] [Normal - JPEG: 1582 x 800 pix - 1.1Mk] [Hires - JPEG: 3000 x 1517 pix - 3.6M] PR Photo 04b/01 shows the ramp leading to the main entrance to the partly subterranean Residencia , with the steel skeleton for the dome over the central area in place. ESO PR Photo 04c/01 ESO PR Photo 04c/01 [Preview - JPEG: 498 x 400 pix - 65k] [Normal - JPEG: 995 x 800 pix - 640k] [Hires - JPEG: 3000 x 2411 pix - 6.6M] PR Photo 04c/01 is an indoor view of the reception hall under the dome, looking towards the main entrance. ESO PR Photo 04d/01 ESO PR Photo 04d/01 [Preview - JPEG: 472 x 400 pix - 61k] [Normal - JPEG: 944 x 800 pix - 632k] [Hires - JPEG: 3000 x 2543 pix - 5.8M] PR Photo 04d/01 shows the ramps from the reception area towards the rooms. The VLT Interferometer The Delay Lines consitute a most important element of the VLT Interferometer , cf. PR Photos 26a-e/00. At this moment, two Delay Lines are operational on site. A third system will be integrated early this year. The VLTI Delay Line is located in an underground tunnel that is 168 metres long and 8 metres wide. This configuration has been designed to accommodate up to eight Delay Lines, including their transfer optics in an ideal environment: stable temperature, high degree of cleanliness, low levels of straylight, low air turbulence. The positions of the Delay Line carriages are computed to adjust the Optical Path Lengths requested for the fringe pattern observation. The positions are controlled in real time by a laser metrology system, specially developed for this purpose. The position precision is about 20 nm (1 nm = 10 -9 m, or 1 millionth of a millimetre) over a distance of 120 metres. The maximum velocity is 0.50 m/s in position mode and maximum 0.05 m/s in operation. The system is designed for 25 year of operation and to survive earthquake up to 8.6 magnitude on the Richter scale. The VLTI Delay Line is a three-year project, carried out by ESO in collaboration with Dutch Space Holdings (formerly Fokker Space) and TPD-TNO . VLTI Delay Lines (December 2000) - ESO PR Video Clip 02b/01 [MPEG - 3.6Mb] ESO PR Video Clip 02b/01 "VLTI Delay Lines (December 2000)" (2000 frames/1:20 min) [MPEG Video+Audio; 160x120 pix; 3.6Mb] [MPEG Video+Audio; 320x240 pix; 13.7 Mb] [RealMedia; streaming; 34kps] [RealMedia; streaming; 200kps] ESO Video Clip 02b/00 shows the Delay Lines of the VLT Interferometer facility at Paranal during tests. One of the carriages is moving on 66-metre long rectified rails, driven by a linear motor. The carriage is equipped with three wheels in order to preserve high guidance accuracy. Another important element is the Cat's Eye that reflects the light from the telescope to the VLT instrumentation. This optical system is made of aluminium (including the mirrors) to avoid thermo-mechanical problems. ESO PR Photo 04e/01 ESO PR Photo 04e/01 [Preview - JPEG: 400 x 402 pix - 62k] [Normal - JPEG: 800 x 804 pix - 544k] [Hires - JPEG: 3000 x 3016 pix - 6.2M] Caption : PR Photo 04e/01 shows one of the 30 "stations" for the movable 1.8-m Auxiliary Telescopes. When one of these telescopes is positioned ("parked") on top of it, The light will be guided through the hole towards the Interferometric Tunnel and the Delay Lines. ESO PR Photo 04f/01 ESO PR Photo 04f/01 [Preview - JPEG: 568 x 400 pix - 96k] [Normal - JPEG: 1136 x 800 pix - 840k] [Hires - JPEG: 3000 x 2112 pix - 4.6M] PR Photo 04f/01 shows a general view of the Interferometric Tunnel and the Delay Lines. ESO PR Photo 04g/01 ESO PR Photo 04g/01 [Preview - JPEG: 406 x 400 pix - 62k] [Normal - JPEG: 812 x 800 pix - 448k] [Hires - JPEG: 3000 x 2956 pix - 5.5M] PR Photo 04g/01 shows one of the Delay Line carriages in parking position. The "NTT Peak" The "NTT Peak" is a mountain top located about 2 km to the north of Paranal. It received this name when ESO considered to move the 3.58-m New Technology Telescope from La Silla to this peak. The possibility of installing the 4-m VISTA telescope (cf. PR 03/00 ) on this peak is now being discussed. ESO PR Photo 04h/01 ESO PR Photo 04h/01 [Preview - JPEG: 630 x 400 pix - 89k] [Normal - JPEG: 1259 x 800 pix - 1.1M] [Hires - JPEG: 3000 x 1907 pix - 5.2M] PR Photo 04h/01 shows the view from the "NTT Peak" towards south, vith the Paranal mountain and the VLT enclosures in the background. ESO PR Photo 04i/01 ESO PR Photo 04i/01 [Preview - JPEG: 516 x 400 pix - 50k] [Normal - JPEG: 1031 x 800 pix - 664k] [Hires - JPEG: 3000 x 2328 pix - 6.0M] PR Photo 04i/01 is a view towards the "NTT Peak" from the top of the Paranal mountain. The access road and the concrete pillar that was used to support a site testing telescope at the top of this peak are seen This is the caption to ESO PR Photos 04a-1/01 and PR Video Clips 02a-b/01 . They may be reproduced, if credit is given to the European Southern Observatory. The ESO PR Video Clips service to visitors to the ESO website provides "animated" illustrations of the ongoing work and events at the European Southern Observatory. The most recent clip was: ESO PR Video Clip 01/01 about the Physics On Stage Festival (11 January 2001) . Information is also available on the web about other ESO videos.
NASA Astrophysics Data System (ADS)
Cruvinel, Paulo E.; Crestana, Sílvio; Artaxo, Paulo; Martins, JoséV.; Armelin, Maria JoséA.
1996-04-01
In the field of soil physics, a technique which permits a non-destructive, accurate and fast elemental analysis with a minimum of sample preparation effort is often desired. Although trace elements are minor components of the solid phase, they play an important role in soil fertility. Cr is of nutritional importance because it is a required element in human and animal nutrition. The immobility of Cr may be responsible for an inadequate Cr supply to plants. This work not only demonstrates the suitability of PIXE as a fast and non-destructive technique, useful to measure Cr content in soil samples, but also outlines a study of spatial variability of that element in agricultural field. To demonstrate the capability of the method soil samples were collected in a 5000 m 2 agricultural field. The soil samples were analyzed using both PIXE and INAA techniques. Besides, a Fourier interpolation technique was used to verify the distribution of Cr along of the sampled field. INAA was carried out by means of the γ-ray emitted by 51Cr(320 keV). Results show that there is a good linear relationship between the elemental concentration of Cr obtained using those techniques, i.e. a correlation coefficient of r2 = 0.82 was achieved.
PIXE analysis of medieval silver coins
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abdelouahed, H. Ben, E-mail: habdelou@cern.ch; Gharbi, F.; Roumie, M.
2010-01-15
We applied the proton-induced X-ray emission (PIXE) analytical technique to twenty-eight medieval silver coins, selected from the Tunisian treasury. The purpose is to study the fineness evolution from the beginning of the 7th to the 15th centuries AD. Each silver coin was cleaned with a diluted acid solution and then exposed to a 3 MeV proton beam from a 1.7 MV tandem accelerator. To allow the simultaneous detection of light and heavy elements, a funny aluminum filter was positioned in front of the Si(Li) detector entrance which is placed at 135{sup o} to the beam direction. The elements Cu, Pb,more » and Au were observed in the studied coins along with the major component silver. The concentration of Ag, presumably the main constituent of the coins, varies from 55% to 99%. This significant variation in the concentration of the major constituent reveals the economical difficulties encountered by each dynasty. It could be also attributed to differences in the composition of the silver mines used to strike the coins in different locations. That fineness evolution also reflects the poor quality of the control practices during this medieval period. In order to verify the ability of PIXE analytical method to distinguish between apparently similar coins, we applied hierarchical cluster analysis to our results to classify them into different subgroups of similar elemental composition.« less
Electrochemical vs X-ray Spectroscopic Measurements of NiFe(CN)6 Crystals
NASA Astrophysics Data System (ADS)
Peecher, Benjamin; Hampton, Jennifer
Pseudocapacitive materials like hexacyanoferrate have greater energy storage capabilities than standard capacitors while maintaining an ability to charge and discharge quickly. We modify the surface of an electrodeposited Ni thin film with a layer of hexacyanoferrate. Charging and discharging these modified films using cyclic voltammetry (CV) allows us to measure the electrochemically active Fe in the film. To determine how closely this resembles the full amount of Fe in the film, we measure the films' composition using particle-induced x-ray emission (PIXE). We also vary the amount of Ni deposited, both to compare the electrolysis value of charge deposited to the PIXE measurement of Ni in the film, and also to measure how varying the thickness of the Ni surface affects the presence of Fe in the film. Comparisons of the CV and PIXE measurements show agreement in Ni levels but disagreement in Fe levels. PIXE measurements of Fe in the film have positive correlation with Ni in the film. This correlation between PIXE measurements of Ni and Fe suggests that PIXE provides a reliable measure of Fe in the film. This implies that a variable proportion of total Fe in a given film is electrochemically active. This research was made possible by the Hope College Department of Physics Frissel Research Fund and the National Science Foundation under Grants RUI-DMR-1104725, MRI-CHE-0959282, and MRI/RUI-PHY-0319523.
Proton-Induced X-Ray Emission Analysis of Crematorium Emissions
NASA Astrophysics Data System (ADS)
Ali, Salina; Nadareski, Benjamin; Yoskowitz, Joshua; Labrake, Scott; Vineyard, Michael
2014-09-01
There has been considerable debate in recent years about possible mercury emissions from crematoria due to amalgam tooth restorations. We have performed a proton-induced X-ray emission (PIXE) analysis of aerosol and soil samples taken near the Vale Cemetery Crematorium in Schenectady, NY, to address this concern. The aerosol samples were collected on the roof of the crematorium using a nine-stage, cascade impactor that separates the particulate matter by aerodynamic diameter and deposits it onto thin Kapton foils. The soil samples were collected at several different distances from the crematorium and compressed into pellets with a hydraulic press. The Kapton foils containing the aerosol samples and the soil pellets were bombarded with 2.2-MeV protons from the 1.1-MV tandem Pelletron accelerator in the Union College Ion-Beam Analysis Laboratory. We measured significant concentrations of sulfur, phosphorus, potassium, calcium, and iron, but essentially no mercury in the aerosol samples. The lower limit of detection for airborne mercury in this experiment was approximately 0.2 ng / m3. The PIXE analysis of the soil samples showed the presence of elements commonly found in soil (Si, K, Ca, Ti, Mn, Fe), but no trace of mercury. There has been considerable debate in recent years about possible mercury emissions from crematoria due to amalgam tooth restorations. We have performed a proton-induced X-ray emission (PIXE) analysis of aerosol and soil samples taken near the Vale Cemetery Crematorium in Schenectady, NY, to address this concern. The aerosol samples were collected on the roof of the crematorium using a nine-stage, cascade impactor that separates the particulate matter by aerodynamic diameter and deposits it onto thin Kapton foils. The soil samples were collected at several different distances from the crematorium and compressed into pellets with a hydraulic press. The Kapton foils containing the aerosol samples and the soil pellets were bombarded with 2.2-MeV protons from the 1.1-MV tandem Pelletron accelerator in the Union College Ion-Beam Analysis Laboratory. We measured significant concentrations of sulfur, phosphorus, potassium, calcium, and iron, but essentially no mercury in the aerosol samples. The lower limit of detection for airborne mercury in this experiment was approximately 0.2 ng / m3. The PIXE analysis of the soil samples showed the presence of elements commonly found in soil (Si, K, Ca, Ti, Mn, Fe), but no trace of mercury. Union College Department of Physics and Astronomy.
NASA Astrophysics Data System (ADS)
La Rosa, Vanessa; Kacperek, Andrzej; Royle, Gary; Gibson, Adam
2014-06-01
Metal fiducial markers are often implanted on the back of the eye before proton therapy to improve target localization and reduce patient setup errors. We aim to detect characteristic x-ray emissions from metal targets during proton therapy to verify the treatment range accuracy. Initially gold was chosen for its biocompatibility properties. Proton-induced x-ray emissions (PIXE) from a 15 mm diameter gold marker were detected at different penetration depths of a 59 MeV proton beam at the CATANA proton facility at INFN-LNS (Italy). The Monte Carlo code Geant4 was used to reproduce the experiment and to investigate the effect of different size markers, materials, and the response to both mono-energetic and fully modulated beams. The intensity of the emitted x-rays decreases with decreasing proton energy and thus decreases with depth. If we assume the range to be the depth at which the dose is reduced to 10% of its maximum value and we define the residual range as the distance between the marker and the range of the beam, then the minimum residual range which can be detected with 95% confidence level is the depth at which the PIXE peak is equal to 1.96 σbkg, which is the standard variation of the background noise. With our system and experimental setup this value is 3 mm, when 20 GyE are delivered to a gold marker of 15 mm diameter. Results from silver are more promising. Even when a 5 mm diameter silver marker is placed at a depth equal to the range, the PIXE peak is 2.1 σbkg. Although these quantitative results are dependent on the experimental setup used in this research study, they demonstrate that the real-time analysis of the PIXE emitted by fiducial metal markers can be used to derive beam range. Further analysis are needed to demonstrate the feasibility of the technique in a clinical setup.
Ion beam analysis of rubies and their simulants
NASA Astrophysics Data System (ADS)
Juncomma, U.; Intarasiri, S.; Bootkul, D.; Tippawan, U.
2014-07-01
Ion beam analysis (IBA) is a set of well known powerful analytical techniques which use energetic particle beam as a probe. Among them, two techniques are suitable for gemological analysis, i.e., Particle Induced X-rays Emission (PIXE) and Ionoluminescence (IL). We combine these two techniques for the investigations of rubies and their simulants. The main objective is to find a reference fingerprint of these gemstones. The data are collected from several natural rubies, synthetic rubies, red spinels, almandine garnets and rubellite which very much resemble and are difficult to distinguish with the gemologist loupe. From our measurements, due to their different crystal structures and compositions, can be clearly distinguished by the IL and PIXE techniques. The results show that the PIXE spectra consist of a few dominant lines of the host matrix elements of each gemstone and some weaker lines due to trace elements of transition metals. PIXE can easily differentiate rubies from other stones by evaluating their chemical compositions. It is noticed that synthetic rubies generally contain fewer impurities, lower iron and higher chromium than the natural ones. Moreover, the IL spectrum of ruby is unique and different from those of others stones. The typical spectrum of ruby is centered at 694 nm, with small sidebands that can be ascribed to a Cr3+ emission spectrum which is dominated by an R-line at the extreme red end of the visible part of the electromagnetic spectrum. Although the spectrum of synthetic ruby is centered at the same wavelength, the peak is stronger due to higher concentration of Cr and lower concentration of Fe than for natural rubies. For spinel, the IL spectrum shows strong deformation where the R-line is split due to the presence of MgO. For rubellite, the peak center is shifted to 692 nm which might be caused by the replacement of Mn3+ at the Al3+ site of the host structure. It is noticed that almandine garnet is not luminescent due to the idiochromatic nature of the stone.
Report about the Solar Eclipse on August 11, 1999
NASA Astrophysics Data System (ADS)
1999-08-01
This webpage provides information about the total eclipse on Wednesday, August 11, 1999, as it was seen by ESO staff, mostly at or near the ESO Headquarters in Garching (Bavaria, Germany). The zone of totality was about 108 km wide and the ESO HQ were located only 8 km south of the line of maximum totality. The duration of the phase of totality was about 2 min 17 sec. The weather was quite troublesome in this geographical area. Heavy clouds moved across the sky during the entire event, but there were also some holes in between. Consequently, sites that were only a few kilometres from each other had very different viewing conditions. Some photos and spectra of the eclipsed Sun are displayed below, with short texts about the circumstances under which they were made. Please note that reproduction of pictures on this webpage is only permitted, if the author is mentioned as source. Information made available before the eclipse is available here. Eclipse Impressions at the ESO HQ Photo by Eddy Pomaroli Preparing for the Eclipse Photo: Eddy Pomaroli [JEG: 400 x 239 pix - 116k] [JPEG: 800 x 477 pix - 481k] [JPEG: 3000 x 1789 pix - 3.9M] Photo by Eddy Pomaroli During the 1st Partial Phase Photo: Eddy Pomaroli [JPEG: 400 x 275 pix - 135k] [JPEG: 800 x 549 pix - 434k] [JPEG: 2908 x 1997 pix - 5.9M] Photo by Hamid Mehrgan Heavy Clouds Above Digital Photo: Hamid Mehrgan [JPEG: 400 x 320 pix - 140k] [JPEG: 800 x 640 pix - 540k] [JPEG: 1280 x 1024 pix - 631k] Photo by Olaf Iwert Totality Approaching Digital Photo: Olaf Iwert [JPEG: 400 x 320 pix - 149k] [JPEG: 800 x 640 pix - 380k] [JPEG: 1280 x 1024 pix - 536k] Photo by Olaf Iwert Beginning of Totality Digital Photo: Olaf Iwert [JPEG: 400 x 236 pix - 86k] [JPEG: 800 x 471 pix - 184k] [JPEG: 1280 x 753 pix - 217k] Photo by Olaf Iwert A Happy Eclipse Watcher Digital Photo: Olaf Iwert [JPEG: 400 x 311 pix - 144k] [JPEG: 800 x 622 pix - 333k] [JPEG: 1280 x 995 pix - 644k] ESO HQ Eclipse Video Clip [MPEG-version] ESO HQ Eclipse Video Clip (2425 frames/01:37 min) [MPEG Video; 160x120 pix; 2.2M] [MPEG Video; 320x240 pix; 4.4Mb] [RealMedia; streaming; 33kps] [RealMedia; streaming; 200kps] This Video Clip was prepared from a "reportage" of the event at the ESO HQ that was transmitted in real-time to ESO-Chile via ESO's satellite link. It begins with some sequences of the first partial phase and the eclipse watchers. Clouds move over and the landscape darkens as the phase of totality approaches. The Sun is again visible at the very moment this phase ends. Some further sequences from the second partial phase follow. Produced by Herbert Zodet. Dire Forecasts The weather predictions in the days before the eclipse were not good for Munich and surroundings. A heavy front with rain and thick clouds that completely covered the sky moved across Bavaria the day before and the meteorologists predicted a 20% chance of seeing anything at all. On August 10, it seemed that the chances were best in France and in the western parts of Germany, and much less close to the Alps. This changed to the opposite during the night before the eclipse. Now the main concern in Munich was a weather front approaching from the west - would it reach this area before the eclipse? The better chances were then further east, nearer the Austrian border. Many people travelled back and forth along the German highways, many of which quickly became heavily congested. Preparations About 500 persons, mostly ESO staff with their families and friends, were present at the ESO HQ in the morning of August 11. Prior to the eclipse, they received information about the various aspects of solar eclipses and about the specific conditions of this one in the auditorium. Protective glasses were handed out and it was the idea that they would then follow the eclipse from outside. In view of the pessimistic weather forecasts, TV sets had been set up in two large rooms, but in the end most chose to watch the eclipse from the terasse in front of the cafeteria and from the area south of the building. Several telescopes were set up among the trees and on the adjoining field (just harvested). Clouds and Holes It was an unusual solar eclipse experience. Heavy clouds were passing by with sudden rainshowers, but fortunately there were also some holes with blue sky in between. While much of the first partial phase was visible through these, some really heavy clouds moved in a few minutes before the total phase, when the light had begun to fade. They drifted slowly - too slowly! - towards the east and the corona was never seen from the ESO HQ site. From here, the view towards the eclipsed Sun only cleared at the very instant of the second "diamond ring" phenomenon. This was beautiful, however, and evidently took most of the photographers by surprise, so very few, if any, photos were made of this memorable moment. Temperature Curve by Benoit Pirenne Temperature Curve on August 11 [JPEG: 646 x 395 pix - 35k] Measured by Benoit Pirenne - see also his meteorological webpage Nevertheless, the entire experience was fantastic - there were all the expected effects, the darkness, the cool air, the wind and the silence. It was very impressive indeed! And it was certainly a unique day in ESO history! Carolyn Collins Petersen from "Sky & Telescope" participated in the conference at ESO in the days before and watched the eclipse from the "Bürgerplatz" in Garching, about 1.5 km south of the ESO HQ. She managed to see part of the totality phase and filed some dramatic reports at the S&T Eclipse Expedition website. They describe very well the feelings of those in this area! Eclipse Photos Several members of the ESO staff went elsewhere and had more luck with the weather, especially at the moment of totality. Below are some of their impressive pictures. Eclipse Photo by Philippe Duhoux First "Diamond Ring" [JPEG: 400 x 292 pix - 34k] [JPEG: 800 x 583 pix - 144k] [JPEG: 2531 x 1846 pix - 1.3M] Eclipse Photo by Philippe Duhoux Totality [JPEG: 400 x 306 pix - 49k] [JPEG: 800 x 612 pix - 262k] [JPEG: 3039 x 1846 pix - 3.6M] Eclipse Photo by Philippe Duhoux Second "Diamond Ring" [JPEG: 400 x 301 pix - 34k] [JPEG: 800 x 601 pix - 163k] [JPEG: 2905 x 2181 pix - 2.0M] The Corona (Philippe Duhoux) "For the observation of the eclipse, I chose a field on a hill offering a wide view towards the western horizon and located about 10 kilometers north west of Garching." "While the partial phase was mostly cloudy, the sky went clear 3 minutes before the totality and remained so for about 15 minutes. Enough to enjoy the event!" "The images were taken on Agfa CT100 colour slide film with an Olympus OM-20 at the focus of a Maksutov telescope (f = 1000 mm, f/D = 10). The exposure times were automatically set by the camera. During the partial phase, I used an off-axis mask of 40 mm diameter with a mylar filter ND = 3.6, which I removed for the diamond rings and the corona." Note in particular the strong, detached protuberances to the right of the rim, particularly noticeable in the last photo. Eclipse Photo by Cyril Cavadore Totality [JPEG: 400 x 360 pix - 45k] [JPEG: 800 x 719 pix - 144k] [JPEG: 908 x 816 pix - 207k] The Corona (Cyril Cavadore) "We (C.Cavadore from ESO and L. Bernasconi and B. Gaillard from Obs. de la Cote d'Azur) took this photo in France at Vouzier (Champagne-Ardennes), between Reims and Nancy. A large blue opening developed in the sky at 10 o'clock and we decided to set up the telescope and the camera at that time. During the partial phase, a lot of clouds passed over, making it hard to focus properly. Nevertheless, 5 min before totality, a deep blue sky opened above us, allowing us to watch it and to take this picture. 5-10 Minutes after the totality, the sky was almost overcast up to the 4th contact". "The image was taken with a 2x2K (14 µm pixels) Thomson "homemade" CCD camera mounted on a CN212 Takahashi (200 mm diameter telescope) with a 1/10.000 neutral filter. The acquisition software set exposure time (2 sec) and took images in a complete automated way, allowing us to observe the eclipse by naked eye or with binoculars. To get as many images as possible during totality, we use binning 2x2 to reduce the readout time to 19 sec. Afterward, one of the best image was flat-fielded and processed with a special algorithm that modelled a fit the continuous component of the corona and then subtracted from the original image. The remaining details were enhanced by unsharp masking and added to the original image. Finally, gaussian histogram equalization was applied". Eclipse Photo by Eddy Pomaroli Second "Diamond Ring" [JPEG: 400 x 438 pix - 129k] [JPEG: 731 x 800 pix - 277k] [JPEG: 1940 x 2123 pix - 2.3M] Diamond Ring at ESO HQ (Eddy Pomaroli) "Despite the clouds, we saw the second "diamond ring" from the ESO HQ. In a sense, we were quite lucky, since the clouds were very heavy during the total phase and we might easily have missed it all!". "I used an old Minolta SRT-101 camera and a teleobjective (450 mm; f/8). The exposure was 1/125 sec on Kodak Elite 100 (pushed to 200 ASA). I had the feeling that the Sun would become visible and had the camera pointed, by good luck in the correct direction, as soon as the cloud moved away". Eclipse Photo by Roland Reiss First Partial Phase [JPEG: 400 x 330 pix - 94k] [JPEG: 800 x 660 pix - 492k] [JPEG: 3000 x 2475 pix - 4.5M] End of First Partial Phase (Roland Reiss) "I observed the eclipse from my home in Garching. The clouds kept moving and this was the last photo I was able to obtain during the first partial phase, before they blocked everything". "The photo is interesting, because it shows two more images of the eclipsed Sun, below the overexposed central part. In one of them, the remaining, narrow crescent is particularly well visible. They are caused by reflections in the camera. I used a Minolta camera and a Fuji colour slide film". Eclipse Spectra Some ESO people went a step further and obtained spectra of the Sun at the time of the eclipse. Eclipse Spectrum by Roland Reiss Coronal Spectrum [JPEG: 400 x 273 pix - 94k] [JPEG: 800 x 546 pix - 492k] [JPEG: 3000 x 2046 pix - 4.5M] Coronal Spectrum (CAOS Group) The Club of Amateurs in Optical Spectroscopy (with Carlos Guirao Sanchez, Gerardo Avila and Jesus Rodriguez) obtained a spectrum of the solar corona from a site in Garching, about 2 km south of the ESO HQ. "This is a plot of the spectrum and the corresponding CCD image that we took during the total eclipse. The main coronal lines are well visible and have been identified in the figure. Note in particular one at 6374 Angstrom that was first ascribed to the mysterious substance "Coronium". We now know that it is emitted by iron atoms that have lost nine electrons (Fe X)". The equipment was: * Telescope: Schmidt Cassegrain F/6.3; Diameter: 250 mm * FIASCO Spectrograph: Fibre: 135 micron core diameter F = 100 mm collimator, f = 80 mm camera; Grating: 1300 gr/mm blazed at 500 nm; SBIG ST8E CCD camera; Exposure time was 20 sec. Eclipse Spectrum by Bob Fosbury Chromospheric Spectrum [JPEG: 120 x 549 pix - 20k] Chromospheric and Coronal Spectra (Bob Fosbury) "The 11 August 1999 total solar eclipse was seen from a small farm complex called Wolfersberg in open fields some 20km ESE of the centre of Munich. It was chosen to be within the 2min band of totality but likely to be relatively unpopulated". "There were intermittent views of the Sun between first and second contact with quite a heavy rainshower which stopped 9min before totality. A large clear patch of sky revealed a perfect view of the Sun just 2min before second contact and it remained clear for at least half an hour after third contact". "The principal project was to photograph the spectrum of the chromosphere during totality using a transmission grating in front of a moderate telephoto lens. The desire to do this was stimulated by a view of the 1976 eclipse in Australia when I held the same grating up to the eclipsed Sun and was thrilled by the view of the emission line spectrum. The trick now was to get the exposure right!". "A sequence of 13 H-alpha images was combined into a looping movie. The exposure times were different, but some attempt has been made to equalise the intensities. The last two frames show the low chromosphere and then the photosphere emerging at 3rd contact. The [FeX] coronal line can be seen on the left in the middle of the sequence. I used a Hasselblad camera and Agfa slide film (RSX II 100)".
Trace element analysis by PIXE in several biomedical fields
NASA Astrophysics Data System (ADS)
Weber, G.; Robaye, G.; Bartsch, P.; Collignon, A.; Beguin, Y.; Roelandts, I.; Delbrouck, J. M.
1984-04-01
Since 1980 in the University of Liége trace element analysis by PIXE has been developed in several directions, among these: the elemental composition of lung parenchyma, hilar lymph nodes, blood content in hematological disorders and renal insufficiency. The content in trace elements of lung tumor and surrounding tissue is measured and compared to similar content previously obtained on unselected patients of comparable ages. The normalization of the bromine deficiency observed in hemodialized patients is achieved by using a dialyzing bath doped with NaBr in order to obtain a normal bromine level of 5.7 μg/ml. The content of Cu, Zn, Br and Se in blood serum from more than 100 patients suffering from malignant hemopathy has been measured. The results are compared with a reference group. These oligoelements have also been measured sequentially for patients under intensive chemotherapy in acute myeloid leukemia.
Trends and sources for heavy metals in urban atmosphere
NASA Astrophysics Data System (ADS)
Kemp, Kåre
2002-04-01
The concentrations of a number of heavy metals in the air in three Danish cities have been measured by means of PIXE for more than two decades. The well-known capability of PIXE for fast and efficient analysis of aerosol samples has been employed for analysis of daily samples from several sites during the whole period. The main sources are traffic, domestic heating and long-range transport. Source apportionment and trends for single metals are assessed by means of simple statistical methods. The most striking change has occurred for the Pb concentration, which is reduced by almost a factor of 100 following the reduction of the Pb content in petrol. The main source of Cu, Cr and Zn is the traffic. The concentrations of these elements have been slightly increasing. The concentrations for most of the other heavy metals, which originate mainly from sources outside the cities, have been decreasing.
An efficient approach to integrated MeV ion imaging.
Nikbakht, T; Kakuee, O; Solé, V A; Vosuoghi, Y; Lamehi-Rachti, M
2018-03-01
An ionoluminescence (IL) spectral imaging system, besides the common MeV ion imaging facilities such as µ-PIXE and µ-RBS, is implemented at the Van de Graaff laboratory of Tehran. A versatile processing software is required to handle the large amount of data concurrently collected in µ-IL and common MeV ion imaging measurements through the respective methodologies. The open-source freeware PyMca, with image processing and multivariate analysis capabilities, is employed to simultaneously process common MeV ion imaging and µ-IL data. Herein, the program was adapted to support the OM_DAQ listmode data format. The appropriate performance of the µ-IL data acquisition system is confirmed through a case study. Moreover, the capabilities of the software for simultaneous analysis of µ-PIXE and µ-RBS experimental data are presented. Copyright © 2017 Elsevier B.V. All rights reserved.
Study of new sheep bone and Zn/Ca ratio around TiAlV screw: PIXE RBS analysis
NASA Astrophysics Data System (ADS)
Guibert, G.; Munnik, F.; Langhoff, J. D.; Von Rechenberg, B.; Buffat, Ph. A.; Laub, D.; Faber, L.; Ducret, F.; Gerber, I.; Mikhailov, S.
2008-03-01
This study reports on in vivo particle induced X-ray emission (PIXE) measurements combined with Rutherford backscattering spectroscopy (RBS) analyses of new remodeled sheep bone formed around TiAlV screws. The implants (screws) were anodized by a modified TiMax™ process. The interface between the implant and the bone was carefully investigated. [Zn]/[Ca] in-depth composition profiles as well as Ca, Fe elemental maps were recorded. The thickness of new bone formed around the screw reached 300-400 μm. Osteon and Osteoid phases were identified in the new bone. A higher [Zn]/[Ca] ratio was observed in the new bone as compared to the mature bone. Blood vessels were observed in the bone in close contact with the screw. This study shows the potential of ion beam analysis for biological and biomedical characterization.
Analysis of memory consolidation and evocation in rats by proton induced X-ray emission
NASA Astrophysics Data System (ADS)
Jobim, P. F. C.; dos Santos, C. E. I.; Maurmann, N.; Reolon, G. K.; Debastiani, R.; Pedroso, T. R.; Carvalho, L. M.; Dias, J. F.
2014-08-01
It is well known that trace elements such as Mg, Ca, Fe, Cu and Zn have a key role in synapse plasticity and learning. Learning process is conventionally divided in three distinct and complementary stages: memory acquisition, consolidation and evocation. Consolidation is the stabilization of the synaptic trace formed by acquisition, while evocation is the recall of this trace. Ion-based techniques capable of providing information concerning the elemental composition of organic tissues may be helpful to improve our understanding on memory consolidation and evocation processes. In particular, the Particle-Induced X-ray Emission (PIXE) technique can be used to analyze different biological tissues with good accuracy. In this work we explore the versatility of PIXE to measure the elemental concentrations in rat brain tissues in order to establish any possible correlation between them and the memory consolidation and evocation processes. To this end, six groups of middle-age male Wistar rats were trained and tested in a step-down Inhibitory Avoidance conditioning. After the behavior tests, the animals were decapitated in accordance with the legal procedures and their brains were removed and dissected for the PIXE analyses. The results demonstrated that there are differences in the elemental concentration among the groups and such variations may be associated with their availability to the learning processes (by memory consolidation and evocation). Moreover, the control groups circumvent the possibility that a non-specific event involved in learning tasks cause such variations. Our results suggest that PIXE may be a useful tool to investigate memory consolidation and evocation in animal models.
NASA Astrophysics Data System (ADS)
Jimenez-Ramos, M. C.; Eriksson, M.; García-López, J.; Ranebo, Y.; García-Tenorio, R.; Betti, M.; Holm, E.
2010-09-01
In order to validate and to gain confidence in two micro-beam techniques: particle induced X-ray emission with nuclear microprobe technique (μ-PIXE) and synchrotron radiation induced X-ray fluorescence in a confocal alignment (confocal SR μ-XRF) for characterization of microscopic particles containing actinide elements (mixed plutonium and uranium) a comparative study has been performed. Inter-comparison of the two techniques is essential as the X-ray production cross-sections for U and Pu are different for protons and photons and not well defined in the open literature, especially for Pu. The particles studied consisted of nuclear weapons material, and originate either in the so called Palomares accident in Spain, 1966 or in the Thule accident in Greenland, 1968. In the determination of the average Pu/U mass ratios (not corrected by self-absorption) in the analysed microscopic particles the results from both techniques show a very good agreement. In addition, the suitability of both techniques for the analysis with good resolution (down to a few μm) of the Pu/U distribution within the particles has been proved. The set of results obtained through both techniques has allowed gaining important information concerning the characterization of the remaining fissile material in the areas affected by the aircraft accidents. This type of information is essential for long-term impact assessments of contaminated sites.
NASA Astrophysics Data System (ADS)
Tros, G. H. J.; Lyaruu, D. M.; Vis, R. D.
1993-10-01
A procedure was developed for analysing the effect of fluoride on mineralization in the enamel of neonatal hamster molars during amelogenesis by means of the quantitative determination of the mineral content. In this procedure the distribution of calcium and mineral concentration was determined in sections containing developing tooth enamel mineral embedded in an organic epoxy resin matrix by means of the micro-PIXE technique. This allowed the determination of the calcium content along preselected tracks with a spatial resolution of 2 μm using a microprobe PIXE setup with a 3 MeV proton beam of 10 to 50 pA with a spot size of 2 μm in the track direction. In this procedure the X-ray yield is used as a measure for the calcium content. The thickness of each sample section is determined independently by measuring the energy loss of α-particles from a calibration source upon passing through the sample. The sample is considered as consisting of two bulk materials, allowing the correction for X-ray self-absorption and the calculation of the calcium concentration. The procedure was applied for measuring the distribution of mineral concentration in 2 μm thick sections taken from tooth germs of hamsters administered with NaF. The measurements indicated that a single intraperitoneal administration of 20 mg NaF/kg body weight to 4-to-5-day-old hamsters leads within 24 h to hypermineralization of certain focal enamel surface areas containing cystic lesions under transitional and early secretory ameloblasts. The mineral concentration there is substantially increased due to the fluoride treatment (35%, instead of 5 to 10% as in the controls), indicating that the normal mineralization process has been seriously disturbed. Furthermore it is found that using this technique the mineral concentration peaks at about 70% at the dentine-enamel junction, which is comparable to that reported for human dentine using other techniques.
Yoshii, Shigeto; Tanaka, Masamitsu; Otsuki, Yoshiro; Fujiyama, Toshiharu; Kataoka, Hideki; Arai, Hajime; Hanai, Hiroyuki; Sugimura, Haruhiko
2001-01-01
Benzo[a]pyrene [B(a)P], a potent procarcinogen found in combustion products such as diesel exhaust and cigarette smoke, has been recently shown to activate the c-Jun NH2-terminal kinase 1 (JNK1) and induce caspase-3-mediated apoptosis in Hepa1c1c7 cells. However, the molecules of the signaling pathway that control the mitogen-activated protein kinase cascades induced by B(a)P and the interaction between those and apoptosis by B(a)P have not been well defined. We report here that B(a)P promoted Cdc42/Rac1, p21-activated kinase 1 (PAK1), and JNK1 activities in 293T and HeLa cells. Moreover, alpha-PAK-interacting exchange factor (α PIX) mRNA and its protein expression were upregulated by B(a)P. While overexpression of an active mutant of α PIX (ΔCH) facilitated B(a)P-induced activation of Cdc42/Rac1, PAK1, and JNK1, overexpression of mutated αPIX (L383R, L384S), which lacks guanine nucleotide exchange factor activity, SH3 domain-deleted αPIX (Δ SH3), which lacks the ability to bind PAK, kinase-negative PAK1 (K299R), and kinase-negative SEK1 (K220A, K224L) inhibited B(a)P-triggered JNK1 activation. Interestingly, overexpression of αPIX (Δ CH) and a catalytically active mutant PAK1 (T423E) accelerated B(a)P-induced apoptosis in HeLa cells, whereas αPIX (Δ SH3), PAK1 (K299R), and SEK 1 (K220A, K224L) inhibited B(a)P-initiated apoptosis. Finally, a preferential caspase inhibitor, Z-Asp-CH2-DCB, strongly blocked the αPIX (Δ CH)-enhanced apoptosis in cells treated with B(a)P but did not block PAK1/JNK1 activation. Taken together, these results indicate that αPIX plays a crucial role in B(a)P-induced apoptosis through activation of the JNK1 pathway kinases. PMID:11564864
Surface analysis of space telescope material specimens
NASA Technical Reports Server (NTRS)
Fromhold, A. T.; Daneshvar, K.
1985-01-01
Qualitative and quantitative data on Space Telescope materials which were exposed to low Earth orbital atomic oxygen in a controlled experiment during the 41-G (STS-17) mission were obtained utilizing the experimental techniques of Rutherford backscattering (RBS), particle induced X-ray emission (PIXE), and ellipsometry (ELL). The techniques employed were chosen with a view towards appropriateness for the sample in question, after consultation with NASA scientific personnel who provided the material specimens. A group of eight samples and their controls selected by NASA scientists were measured before and after flight. Information reported herein include specimen surface characterization by ellipsometry techniques, a determination of the thickness of the evaporated metal specimens by RBS, and a determination of trace impurity species present on and within the surface by PIXE.
Environmental impact of fertilizer industries evaluated by PIXE
NASA Astrophysics Data System (ADS)
Martín, J. E.; Bolívar, J. P.; Respaldiza, M. A.; García-Tenorio, R.; da Silva, M. F.
1995-12-01
In this paper the environmental impact of several phosphogypsum piles sited in the southwest of Spain is studied using multielemental analysis by PIXE of 12 salt marsh and soil samples collected in their surroundings. The piles are used to store the main by-product formed in the production of phosphoric acid and phosphate fertilizers. The samples collected were bombarded with 2.5 MeV protons from the 3 MV Van de Graaff accelerator in the ITN at Sacavèm (Portugal), and 20 elements from Al to Pb were detected. The results obtained reinforce previous radioanalytical determinations concerning the significant radioactive contamination pathways (leaching or/and dissolution of elements by water from the piles) and the negligible pathways (atmospheric and direct aquatic transport).
Overview of the Micro Vertex Detector for the P bar ANDA experiment
NASA Astrophysics Data System (ADS)
Calvo, Daniela; P¯ANDA MVD Group
2017-02-01
The P bar ANDA experiment is devoted to study interactions between cooled antiproton beams and a fixed target (the interaction rate is of about 107 events/s), hydrogen or heavier nuclei. The innermost tracker of P bar ANDA is the Micro Vertex Detector (MVD), specially designed to ensure the secondary vertex resolution for the discrimination of short-lived charmonium states. Hybrid epitaxial silicon pixels and double-sided silicon microstrips will equip four barrels, arranged around the interaction point, and six forward disks. The experiment features a triggerless architecture with a master clock of 160 MHz, therefore the MVD has to run with a continuous data transmission where the hits need precise timestamps. The energy loss of the particles in the sensor will be measured as well. The challenging request of a triggerless readout suggested to develop custom readout chips for both pixel (ToPix) and microstrip (PASTA) devices. To validate components and the triggerless readout architecture, prototypes have been built and tested. After an overview of the MVD, the technological aspects and performances of some prototypes will be reported.
Singh, Sudhir P; Vogel-Mikuš, Katarina; Arčon, Iztok; Vavpetič, Primož; Jeromel, Luka; Pelicon, Primož; Kumar, Jitendra; Tuli, Rakesh
2013-08-01
Iron insufficiency is a worldwide problem in human diets. In cereals like wheat, the bran layer of the grains is an important source of iron. However, the dietary availability of iron in wheat flour is limited due to the loss of the iron-rich bran during milling and processing and the presence of anti-nutrients like phytic acid that keep iron strongly chelated in the grain. The present study investigated the localization of iron and phosphorus in grain tissues of wheat genotypes with contrasting grain iron content using synchrotron-based micro-X-ray fluorescence (micro-XRF) and micro-proton-induced X-ray emission (micro-PIXE). X-ray absorption near-edge spectroscopy (XANES) was employed to determine the proportion of divalent and trivalent forms of Fe in the grains. It revealed the abundance of oxygen, phosphorus, and sulphur in the local chemical environment of Fe in grains, as Fe-O-P-R and Fe-O-S-R coordination. Contrasting differences were noticed in tissue-specific relative localization of Fe, P, and S among the different genotypes, suggesting a possible effect of localization pattern on iron bioavailability. The current study reports the shift in iron distribution from maternal to filial tissues of grains during the evolution of wheat from its wild relatives to the present-day cultivated varieties, and thus suggests the value of detailed physical localization studies in varietal improvement programmes for food crops.
Design and Development of a Virtual Facility Tour Using iPIX(TM) Technology
NASA Technical Reports Server (NTRS)
Farley, Douglas L.
2002-01-01
The capabilities of the iPIX virtual tour software, in conjunction with a web-based interface create a unique and valuable system that provides users with an efficient virtual capability to tour facilities while being able to acquire the necessary technical content is demonstrated. A users guide to the Mechanics and Durability Branch's virtual tour is presented. The guide provides the user with instruction on operating both scripted and unscripted tours as well as a discussion of the tours for Buildings 1148, 1205 and 1256 and NASA Langley Research Center. Furthermore, an indepth discussion has been presented on how to develop a virtual tour using the iPIX software interface with conventional html and JavaScript. The main aspects for discussion are on network and computing issues associated with using this capability. A discussion of how to take the iPIX pictures, manipulate them and bond them together to form hemispherical images is also presented. Linking of images with additional multimedia content is discussed. Finally, a method to integrate the iPIX software with conventional HTML and JavaScript to facilitate linking with multi-media is presented.
PIXE analysis of sand and soil from Ulaanbaatar and Karakurum, Mongolia
NASA Astrophysics Data System (ADS)
Markwitz, A.; Barry, B.; Shagjjamba, D.
2008-09-01
Twenty-one sand and soil samples were collected at the surface from 22 to 25 June 2007 at sampling sites from Ulaanbaatar to Karakurum, Mongolia. The sand samples were collected from constantly changing sand dunes which may still contain salt from prehistoric oceans. The dry sand and soil samples were processed for PIXE and PIGE analyses. A clear division between soils and sand become apparent in the silicon results. Concentrations of all bulk elements in human habitation samples and of Si, Al, K and Fe in dry lake/flood plain samples are similar to those in the soils and sands. Among elements which could be regarded as being at trace concentrations the average S concentration in the soils is 0.9 g kg-1 whereas it is not detected in the sand samples. Zinc and Cu concentrations are both higher in the soils than the sands and are strongly correlated. A surprising presence of uranium at a concentration of 350 mg kg-1 was detected in the PIXE measurement on one of the dry lake samples. Gamma spectrometry confirmed the presence of U in this sample and also at a lower level in a sample from the lake shore, but in none of the other samples. Further, the gamma spectrometry showed that 238U decay products were present only at a level corresponding to about 3 mg kg-1 U for a system in radioactive equilibrium, a figure which is typical for U in the earth's crust. Disequilibria between 238U and its decay products occur naturally but such a high degree of separation at high concentration would be unique if confirmed. PIXE and PIGE measurements of these samples highlight the difficulty in correlating trace element measurements with occurrence of indicators of sea salt in air particulate samples.
NASA Astrophysics Data System (ADS)
Lei, Qiantao; Liu, Ke; Gao, Jie; Li, Xiaolin; Shen, Hao; Li, Yan
2017-08-01
Nickel-based alloys as candidate materials for Thorium Molten Salt Reactor (TMSR), need to be used under high temperature in molten salt environment. In order to ensure the safety of the reactor running, it is necessary to study the elemental move characteristic of nickel-based alloys in the high temperature molten salts. In this work, the scanning nuclear microprobe at Fudan University was applied to study the elemental move. The Nickel-based alloy samples were corroded by molten salt at different temperatures. The element concentrations in the Nickel-based alloys samples were determined by the scanning nuclear microprobe. Micro-PIXE results showed that the element concentrations changed from the interior to the exterior of the alloy samples after the corrosion.
Leaf elemental analysis in mycorrhizal post oak seedlings
NASA Astrophysics Data System (ADS)
Boling, B. C.; Naab, F. U.; Smith, D.; Duggan, J. L.; McDaniel, F. D.
2006-09-01
Growth and element assimilation was investigated in the leaves of post oak seedlings exposed to four different treatment combinations of fertilization and ectomycorrhizal inoculation. Element concentration was analyzed via particle-induced X-ray emission spectrometry (PIXE). PIXE detected 10 of the 13 essential macro and micronutrients: P, S, Mg, Ca, K, Cu, Zn, Mn, Fe and Cl. Mean growth and dry weight was significantly different across the treatment groups as well as the mean concentration of Mg, Al, S, K, Ca, Fe, Cu and Zn. The data suggest that fertilization rather than mycorrhizal inoculation had a stronger influence on nutrient uptake. This study is the first to analyze element concentration in post oak and to investigate the potential benefits of mycorrhizal symbiosis in post oak seedlings in terms of nutrient uptake.
Analysis of elemental composition of porcelains unearthed from Waguantan kiln site by PIXE-RBS
NASA Astrophysics Data System (ADS)
Zhou, Z.; Zhang, K.; Xia, C. D.; Liu, M. T.; Zhu, J. J.; An, Z.; Bai, B.
2015-03-01
A method combining proton-induced X-ray emission spectrometry (PIXE) and Rutherford backscattering spectrometry (RBS) was used to determine the composition of 61 porcelain shards from the Yuan Dynasty (1271-1368 A.D.) unearthed from the Waguantan kiln site at Tianzhu County in Guizhou Province, China. Based on our previous experimental setup, an electron gun device with a LaB6 crystal cathode was installed to solve the problem created when the incident proton beams generated electric charge accumulations on the surfaces of the insulating porcelain samples, which induced a large bremsstrahlung background. The use of the electron gun has largely eliminated the large bremsstrahlung background and has therefore improved the detection limits for elements, especially for trace elements, and made it possible to determine the origin of the porcelains based on the trace elements. Major and trace elemental compositions of the porcelain bodies and glazes measured by PIXE and RBS were analyzed by the factor analysis method. The factor analysis showed that a few pieces of porcelain with a style similar to the porcelain of the Longquan kiln among the unearthed porcelains from the Waguantan kiln site did not have obvious differences in elemental compositions from other remaining porcelains unearthed from the Waguantan kiln site, indicating that the pieces of unearthed porcelain with the Longquan kiln style did in fact belong to the product fired locally by imitating the model of the Longquan celadon with local raw materials. This result therefore indicated that the Longquan kiln technology that originated from the Five Dynasties (907-960 A.D.) had been propagated to the Waguantan kiln site of Guizhou Province in the Yuan Dynasty.
Differential PIXE for investigating the layer structure of paintings
NASA Astrophysics Data System (ADS)
Mandò, P. A.; Fedi, M. E.; Grassi, N.; Migliori, A.
2005-09-01
This paper reports an example of how the differential PIXE technique can be successfully applied to the investigation of wood or canvas paintings. The work analysed is a famous wood painting by Leonardo da Vinci, the "Madonna dei fusi" (ex-Reford version, 1501), chosen for a pilot study in a wide international project aimed at analysing Leonardo's works of art by means of non-destructive techniques. While illustrating the results obtained concerning the identification of pigments and the discrimination of the stratigraphy of layers, the merits and limits of differential PIXE in general are pointed out.
Kutys, Matthew L; Yamada, Kenneth M
2014-09-01
Rho-family GTPases govern distinct types of cell migration on different extracellular matrix proteins in tissue culture or three-dimensional (3D) matrices. We searched for mechanisms selectively regulating 3D cell migration in different matrix environments and discovered a form of Cdc42-RhoA crosstalk governing cell migration through a specific pair of GTPase activator and inhibitor molecules. We first identified βPix, a guanine nucleotide exchange factor (GEF), as a specific regulator of migration in 3D collagen using an affinity-precipitation-based GEF screen. Knockdown of βPix specifically blocks cell migration in fibrillar collagen microenvironments, leading to hyperactive cellular protrusion accompanied by increased collagen matrix contraction. Live FRET imaging and RNAi knockdown linked this βPix knockdown phenotype to loss of polarized Cdc42 but not Rac1 activity, accompanied by enhanced, de-localized RhoA activity. Mechanistically, collagen phospho-regulates βPix, leading to its association with srGAP1, a GTPase-activating protein (GAP), needed to suppress RhoA activity. Our results reveal a matrix-specific pathway controlling migration involving a GEF-GAP interaction of βPix with srGAP1 that is critical for maintaining suppressive crosstalk between Cdc42 and RhoA during 3D collagen migration.
Expert Images for All Audiences: The AstroPix Archive
NASA Astrophysics Data System (ADS)
Hurt, Robert; Llamas, Jacob; Wyatt, Ryan Jason; Christensen, Lars
2018-01-01
The AstroPix project provides one-stop-shopping for an extensive collection of the finest astronomical imagery, sourced from some of the world’s most prominent observatories. The archive is made possible by a grassroots effort to tag publicly-released imagery using the Astronomical Visualization Metadata (AVM) standard, which captures rich contextual information for each image. While the site has been in development for many years, it is now supported under NASA’s Universe of Learning collaboration, and AstroPix has been updated and deployed to cloud services. The AVM tags provide many unique features including spectral color assignments, sky context (using AAS WorldWide Telescope APIs), and direct links to the original source material on the web. The 7,000+ assets currently include imagery provided by Chandra, ESO, GALEX, Herschel, Hubble, NuSTAR, Spitzer, and WISE. The assets are also provided for use in the planetarium community by supporting the Data2Dome (D2D) initiative. AstroPix imagery is designed to be used in a variety of unique ways that benefit formal and informal education as well as astronomers and the general public. Observatories can add their own image archives to AstroPix by tagging their assets and providing a simple XML feed, increasing the value of their data to the community at large.
Ascertaining serum levels of trace elements in melanoma patients using PIXE and HR-ICPMS
NASA Astrophysics Data System (ADS)
Bernardes, S.; Tabacniks, M. H.; Santos, I. D. A. O.; Oliveira, A. F.; Shie, J. N.; Sarkis, J. E. S.; Oliveira, T.
2014-01-01
Melanoma is a serious and deadly form of skin cancer. However, patients' chances of survival and recovery are considerably increased when it is diagnosed and treated in its early stages. In this study, trace element concentrations in serum samples from patients with melanoma were measured using PIXE (Proton Induced X-ray Emission) and HR-ICPMS (High-Resolution Inductively Coupled Plasma Mass Spectrometry), with the purpose of correlating these concentrations with the disease. Blood samples from 30 melanoma patients and 116 healthy donors were collected at São Paulo Hospital (protocol CEP 1036/08 UNIFESP). Relevant clinical information on the patients has also been included in the statistical analysis. Analysis of the control group showed different P and Mg concentrations in individuals above and below 40 years of age. P, S, Ca, Cu and Zn concentrations in healthy individuals differed according to gender, highlighting the necessity to include age and gender variables in the case-control analysis. There were also differences in K, S, Ca and Se concentrations between the control and melanoma groups.
Detection of trace metallic elements in oral lichenoid contact lesions using SR-XRF, PIXE, and XAFS
Sugiyama, Tomoko; Uo, Motohiro; Wada, Takahiro; Omagari, Daisuke; Komiyama, Kazuo; Miyazaki, Serika; Numako, Chiya; Noguchi, Tadahide; Jinbu, Yoshinori; Kusama, Mikio; Mori, Yoshiyuki
2015-01-01
Oral lichen planus (OLP) and oral lichenoid contact lesions (OLCL) are chronic inflammatory mucocutaneous reactions with a risk of malignant transformation that alter the epithelium. OLP and OLCL have similar clinical and histopathological features and it is difficult to distinguish one from the other. Metallic restorations are suspected to generate OLCLs. Trace metal analysis of OLCL specimens may facilitate the discrimination of symptoms and identification of causative metallic restorations. The purpose of this study was to assess OLCL tissue samples for the prevalence of metallic elements derived from dental restorations, and to discriminate OLCL from OLP by using synchrotron radiation-excited X-ray fluorescence analysis (SR-XRF), particle-induced X-ray emission (PIXE), and X-ray absorption fine structure (XAFS). Typical elements of dental materials were detected in the OLCL, whereas no obvious element accumulation was detected in OLP and negative control specimens. The origin of the detected metallic elements was presumed to be dental alloys through erosion. Therefore, our findings support the feasibility of providing supporting information to distinguish OLCL from OLP by using elemental analysis. PMID:26085368
H+, O2+, O3+ and high resolution PIXE spectra of Yb2O3
NASA Astrophysics Data System (ADS)
Chaves, P. C.; Reis, M. A.
2017-11-01
The number of X-ray spectrometry systems having energy resolution of the order of 10 eV, or less, has increasing recently, included already energy dispersive systems (EDS). Access to previous unseen spectra details and enhanced information including speciation, becomes more common and available. Analysis of high resolution EDS PIXE spectra is, nevertheless a complex task due to the need to carefully account for contributions from minor and satellite transitions. In this work, a pure Yb2O3 sample was irradiated at the HRHE-PIXE setup of C2TN, and simultaneous CdTe and X-ray Microcalorimeter Spectrometer (XMS) spectra were collected. The L-shell spectrum of Yb emitted during irradiations using H+ , O2+ and O3+ ions in the energy range from 1.0 to 6.5 MeV was studied. Measured L X-ray spectra were analysed taking into account the effects of the multiple ionization in the L and M shells. All spectra were analysed using the DT2 code, which allows to include in the fitting model diagram lines as well as multi-ionization satellites and any other contributions. In this communication we present the results and discuss details and problems related to the transition energies, intensity, line width data, and multiple ionization satellites.
NASA Astrophysics Data System (ADS)
Corregidor, V.; Oliveira, A. R.; Rodrigues, P. A.; Alves, L. C.
2015-04-01
Resorting to an external proton microbeam, PIXE analyses of three oil paintings on copper support dated from the XVII century and attributed to the Flemish artist Frans Francken II, were undertaken. The present work aims to contribute to the compositional study of the painting materials employed by XVII century artists that exploited copper as a support for oil painting, and specifically the materials used by Francken's workshop, particularly copper plates. Because of the low thickness of the pictorial layers of this type of paintings and its non-destructive character, PIXE is the ideal technique to study the elemental composition of the paintings. Several spots in each painting were chosen for analysis in order to cover almost all the pigments used in the colour palette. Lead and calcium were detected in practically every analysed regions, probably related to the presence of lead white and chalk, usually used as ground layer on copper paintings. Small quantities of gold were also detected, which is present in many of this artist's works to embellish some details of the representations. Also this work reports the first application of the external proton microbeam set-up available at CTN/IST in Portugal for the characterization of oil paintings.
Trace element mapping in Parkinsonian brain by quantitative ion beam microscopy
NASA Astrophysics Data System (ADS)
Barapatre, Nirav; Morawski, Markus; Butz, Tilman; Reinert, Tilo
2010-06-01
The role of iron in the pathogenesis of the Parkinson's disease (PD) is a current subject of research in Neurochemistry, since an abnormal increase in iron is reported in the substantia nigra (SN) of Parkinsonian patients. A severe loss of the cells containing dopamine in the SN in the PD has also drawn attention towards the function of a browny-black pigment called neuromelanin, which accumulates predominantly in these dopaminergic neurons. The neuromelanin has an ability to chelate metal ions, which, in free state, may cause considerable damage to cells by reacting with their lipid-rich membranes. However, it could also potentiate free radical production if it releases the bound metal ions. The highly sensitive and non-destructive micro-PIXE method suits best to quantify and map the trace elements in the SN. The accuracy in charge measurement for such microanalysis studies is of utmost importance for quantitative analysis. Since a Faraday cup is usually placed behind the thin biological sample to measure the charge, the primary and the secondary electrons, knocked out from the sample by traversing ion beam, hamper an exact charge determination. Hence, a new non-interceptive technique was developed for precise charge measurement and for continuous monitoring of beam current.
Performance and Applications of the first HVE 5MV Tandetron{sup TM} at the University of Madrid
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mous, D.J.W.; Gottdang, A.; Haitsma, R.G.
2003-08-26
The first HVE Tandetron{sup TM} with a nominal terminal voltage of 5 MV has been put into operation at the Universidad Autonoma de Madrid (Spain) as part of their new IBA facility. The accelerator features a coaxial structure in which the all-solid-state power supply is constructed around the high-energy acceleration tube, thereby avoiding the T-shaped tank that has characterized the HVE Tandetrons{sup TM} so far. The new IBA facility covers a number of different ion beam analysis techniques including ERD using heavy-element time-of-flight, RBS, as well as an external micro-beam for PIXE. During installation, tests have shown a stable terminalmore » voltage of 5.5 MV. The terminal voltage ripple was deduced to be below 6 x 10-6 (RMS) for terminal voltages above 800 kV. Terminal voltage undershoot was measured to be 1.4 x 10-3 for a {approx}1 kW beam at 3 MV and recovered to 1 x 10-4 within 800 ms. IBA experiments that require low energy hydrogen beams are supported by a stable terminal voltage down to 100 kV.« less
Single cell elemental analysis using nuclear microscopy
NASA Astrophysics Data System (ADS)
Ren, M. Q.; Thong, P. S. P.; Kara, U.; Watt, F.
1999-04-01
The use of Particle Induced X-ray Emission (PIXE), Rutherford Backscattering Spectrometry (RBS) and Scanning Transmission Ion Microscopy (STIM) to provide quantitative elemental analysis of single cells is an area which has high potential, particularly when the trace elements such as Ca, Fe, Zn and Cu can be monitored. We describe the methodology of sample preparation for two cell types, the procedures of cell imaging using STIM, and the quantitative elemental analysis of single cells using RBS and PIXE. Recent work on single cells at the Nuclear Microscopy Research Centre,National University of Singapore has centred around two research areas: (a) Apoptosis (programmed cell death), which has been recently implicated in a wide range of pathological conditions such as cancer, Parkinson's disease etc, and (b) Malaria (infection of red blood cells by the malaria parasite). Firstly we present results on the elemental analysis of human Chang liver cells (ATTCC CCL 13) where vanadium ions were used to trigger apoptosis, and demonstrate that nuclear microscopy has the capability of monitoring vanadium loading within individual cells. Secondly we present the results of elemental changes taking place in individual mouse red blood cells which have been infected with the malaria parasite and treated with the anti-malaria drug Qinghaosu (QHS).
GridPix detectors: Production and beam test results
NASA Astrophysics Data System (ADS)
Koppert, W. J. C.; van Bakel, N.; Bilevych, Y.; Colas, P.; Desch, K.; Fransen, M.; van der Graaf, H.; Hartjes, F.; Hessey, N. P.; Kaminski, J.; Schmitz, J.; Schön, R.; Zappon, F.
2013-12-01
The innovative GridPix detector is a Time Projection Chamber (TPC) that is read out with a Timepix-1 pixel chip. By using wafer post-processing techniques an aluminium grid is placed on top of the chip. When operated, the electric field between the grid and the chip is sufficient to create electron induced avalanches which are detected by the pixels. The time-to-digital converter (TDC) records the drift time enabling the reconstruction of high precision 3D track segments. Recently GridPixes were produced on full wafer scale, to meet the demand for more reliable and cheaper devices in large quantities. In a recent beam test the contribution of both diffusion and time walk to the spatial and angular resolutions of a GridPix detector with a 1.2 mm drift gap are studied in detail. In addition long term tests show that in a significant fraction of the chips the protection layer successfully quenches discharges, preventing harm to the chip.
BetaPIX and GIT1 regulate HGF-induced lamellipodia formation and WAVE2 transport.
Morimura, Shigeru; Suzuki, Katsuo; Takahashi, Kazuhide
2009-05-08
Formation of lamellipodia is the first step during cell migration, and involves actin reassembly at the leading edge of migrating cells through the membrane transport of WAVE2. However, the factors that regulate WAVE2 transport to the cell periphery for initiating lamellipodia formation have not been elucidated. We report here that in human breast cancer MDA-MB-231 cells, the hepatocyte growth factor (HGF) induced the association between the constitutive complex of betaPIX and GIT1 with WAVE2, which was concomitant with the induction of lamellipodia formation and WAVE2 transport. Although depletion of betaPIX by RNA interference abrogated the HGF-induced WAVE2 transport and lamellipodia formation, GIT1 depletion caused HGF-independent WAVE2 transport and lamellipodia formation. Collectively, we suggest that betaPIX releases cells from the GIT1-mediated suppression of HGF-independent responses and recruits GIT1 to WAVE2, thereby facilitating HGF-induced WAVE2 transport and lamellipodia formation.
Analysis of elements in lake sediment samples by PIXE spectrometry
NASA Astrophysics Data System (ADS)
Chelarescu, E. D.; Radulescu, C.; Stihi, C.; Bretcan, P.; Tanislav, D.; Dulama, I. D.; Stirbescu, R. M.; Teodorescu, S.; Bucurica, I. A.; Andrei, R.; Morarescu, C.
2017-09-01
This work aims to determine the concentrations of several elements (e.g. Pb, Ni, Zn, Mn, Cr, and Fe) from lake sediments, in order to characterize their origin and evolution. Particle Induced X-ray Emission (PIXE) technique using the 3 MV Tandetron™ particle accelerator from National Institute for R&D in Physics and Nuclear Engineering "Horia Hulubei" (IFIN-HH), Magurele-Bucharest, Romania, was applied. Sediment cores from different salt lakes from Romania (i.e. Amara Lake, Caineni Lake, and Movila Miresii Lake) were collected, in August 2015. The content of Pb, Cr, Mn, Fe, and Ni from sediment samples show similarities with other data presented in literature and international regulation. The Zn was the only element with a higher content in all samples (e.g. maximum 401.7-517.3 mg/kg d.w.).
Antibody Fab display and selection through fusion to the pIX coat protein of filamentous phage.
Tornetta, Mark; Baker, Scott; Whitaker, Brian; Lu, Jin; Chen, Qiang; Pisors, Eileen; Shi, Lei; Luo, Jinquan; Sweet, Raymond; Tsui, Ping
2010-08-31
Fab antibody display on filamentous phage is widely applied to de novo antibody discovery and engineering. Here we describe a phagemid system for the efficient display and affinity selection of Fabs through linkage to the minor coat protein pIX. Display was successful by fusion of either Fd or Lc through a short linker to the amino terminus of pIX and co-expression of the counter Lc or Fd as a secreted, soluble fragment. Assembly of functional Fab was confirmed by demonstration of antigen-specific binding using antibodies of known specificity. Phage displaying a Fab specific for RSV-F protein with Fd linked to pIX showed efficient, antigen-specific enrichment when mixed with phage displaying a different specificity. The functionality of this system for antibody engineering was evaluated in an optimization study. A RSV-F protein specific antibody with an affinity of about 2nM was randomized at 4 positions in light chain CDR1. Three rounds of selection with decreasing antigen concentration yielded Fabs with an affinity improvement up to 70-fold and showed a general correlation between enrichment frequency and affinity. We conclude that the pIX coat protein complements other display systems in filamentous phage as an efficient vehicle for low copy display and selection of Fab proteins. 2010 Elsevier B.V. All rights reserved.
14th International Conference on Particle Induced X-ray Emission ("PIXE 2015")
NASA Astrophysics Data System (ADS)
Przybyłowicz, Wojciech Józef; Pineda-Vargas, Carlos
2015-11-01
This special issue of Nuclear Instruments and Methods in Physics Research B contains the proceedings of the 14th International Conference on Particle Induced X-ray Emission ("PIXE 2015") that was held in Somerset West (South Africa) from 25th February to 3rd March 2015.
Computer Graphics: KidPix, the MacIntosh, and Students with Cognitive Disorders.
ERIC Educational Resources Information Center
Olson, Cindy
This teacher's guide provides an overview of KidPix software and contains adaptive applications of the software for Cognitively Disabled-Borderline (CDB) students. Ten lesson plans are given, including: (1) "USing Rubber Stamps/Rubber Stamp Editor"; (2) "Portrait"; (3) "Create a Pattern"; (4) "Garden Mural";…
Presentation Software and the Single Computer.
ERIC Educational Resources Information Center
Brown, Cindy A.
1998-01-01
Shows how the "Kid Pix" software and a single multimedia computer can aid classroom instruction for kindergarten through second grade. Topics include using the computer as a learning center for small groups of students; making a "Kid Pix" slide show; using it as an electronic chalkboard; and creating curriculum-related…
Micro-PIXE study of metal loss from dental amalgam
NASA Astrophysics Data System (ADS)
Meesat, Ridthee; Sudprasert, Wanwisa; Guibert, Edouard; Wang, Liping; Chappuis, Thibault; Whitlow, Harry J.
2017-08-01
Mercury amalgams have been a topic of controversy ever since their introduction over 150 years ago as a dental material. An interesting question is if metals are released from the amalgam into the enamel and dentine tissue. To elucidate this PIXE mapping was used to investigate metal redistribution in an extracted molar tooth with a ∼30 year old high-Cu content amalgam filling. The tooth was sectioned and polished, and elemental mapping carried out on the amalgam/enamel, bulk amalgam and the wear surface of the amalgam. As expected, the amalgam was multiphase amalgam comprising of Cu-rich and Ag-rich grains with non-uniform distribution of Hg. The amalgam/dentine interface was clearly defined with amalgam elements on one side and C and P from hydroxyapatite on the other side with evidence of only slight interface corrosion. The peaks for Cu Hg and Zn were isolated from interfering signals with concentrations in the enamel tissue, observed to be at, or below the method detection limit. The proximity in energy of the Sn L α and Ca K α , peaks and the background on the Hg M α gave signal overlap which increased the MDL for these elements. Remarkably, a course grain texture in the amalgam was observed just below the biting surface of the amalgam which might be associated with tribochemical processes from mastication. This coupled with the clear absence of the amalgam metals from tooth tissue, even in close proximity to the interface, suggests that for this sample, release of Hg occurred via erosion or dissolution in saliva.
NASA Astrophysics Data System (ADS)
Morales, J. R.; Chesta, M. A.; Cancino, S. A.; Miranda, P. A.; Dinator, M. I.; Avila, M. J.
2005-01-01
Proton induced X-ray emission (PIXE) has been applied to the measurement of the production cross section of a radionuclide decaying by electron capture. By performing a PIXE type experiment on the daughter nuclide important advantages are obtained. The determination of some factors with usually large uncertainties, like solid angle and detector efficiency were avoided. The method was applied to the determination of cross section of the reaction 63Cu(d, p)64Cu at 2.4 MeV for 64Cu production. This result is in full agreement with that obtained through the decay of the 1346 keV gamma ray of 64Cu.
Study on the occurrence of platinum in Xinjie CuNi sulfide deposits by a combination of SPM and NAA
NASA Astrophysics Data System (ADS)
Li, Xiaolin; Zhu, Jieqing; Lu, Rongrong; Gu, Yingmei; Wu, Xiankang; Chen, Youhong
1997-07-01
A combination of neutron-activation analysis (NAA) and scanning proton microprobe (SPM) was used to study the distribution of platinum-group elements (PGEs) in rocks and ores from Xinjie CuNi deposit. The minimum detection limits of PGEs by NAA had been much improved by means of a nickel-sulfide fire-assay technique for pre-concentration of PGEs in the ore samples. A simple and effective method was developed for true element mapping in SPM experiments. A pair of moveable absorption filters was set up in the target chamber for high sensitivities of both major and trace elements. The bulk analysis results by NNA indicated that the PGE mineralization occurred at the base of Xinjie layered intrusion in clinopyroxenite rocks and the CuNi sulfide minerals disseminated within the rocks had high abundance level of PGEs. However, the micro-PIXE analysis of the CuNi sulfide mineral grains did not find PGEs above the MDL of 6-9 ppm for Rh, Ru and Pd, and 60 ppm for Pt. The search for platinum occurrence in sulfide minerals was followed by scanning analysis of SPM when some smaller platinum enriched grains were found in the sulfide minerals. The microscopic analysis results suggested that platinum occurred in the CuNi sulfide matrix as independent arsenide mineral grains. The chemical formula of the arsenide sperrylite was PtAs 2. The information of the platinum occurrence was helpful to future mineralogical research and mineral processing and beneficiation of the CuNi deposit.
NASA Astrophysics Data System (ADS)
Pacheco, Adriano M. G.; Freitas, Maria do Carmo; Reis, Miguel A.
2003-06-01
As part of an ongoing evaluation of its suitability for atmospheric biomonitoring, bark from olive trees ( Olea europaea Linn.) has been collected and searched for trace elements by means of two nuclear-analytical techniques—instrumental neutron activation analysis (INAA) and proton-induced X-ray emission (PIXE). The sampling for the present study was carried out across two separate sections of an established grid for air-quality surveys in mainland Portugal. The dual location comprises 58 collection sites—littoral-north (29 sites) and littoral-centre (29 sites). Both techniques are intrinsically accurate and may be seen to complement each other in the way that, as a whole, they yield 46 elements, with an overlap of 16 elements. Among the latter, this paper focuses on four of them and looks into their joint determination. Descriptive statistics for soil-related Al and Ti, and for sea-related Cl and Br, show results for each element to be fairly comparable. The degree of association between elemental patterns by either technique, as seen through nonparametric tests (Kendall's RK), is outstanding. No statistical evidence (Wilcoxon's T) for relative bias in correlated samples—consistently higher or lower results by one technique—could be found as well. As far as this study goes, INAA and PIXE may be used interchangeably for determining the present elements in olive-tree bark.
Comparative analysis of textile metal threads from liturgical vestments and folk costumes in Croatia
NASA Astrophysics Data System (ADS)
Šimić, Kristina; Zamboni, Ivana; Fazinić, Stjepko; Mudronja, Domagoj; Sović, Lea; Gouasmia, Sabrina; Soljačić, Ivo
2018-02-01
Textile is essential for everyday life in all societies. It is used in clothes for protection and warmth but also to indicate class and position, show wealth and social status. Threads from precious metals have also been used in combination with fibres for decoration in order to create luxury fabrics for secular and religious elites. We performed elemental analysis of 17th to 20th century metal threads from various textile articles of liturgical vestments and festive folk costumes collected in the museums of northern, southern and central Croatian regions. In order to determine elemental concentrations in threads we performed comparative X-ray Spectroscopy measurements using: (i) Scanning Electron Microscopy with Energy Dispersive X-ray Spectroscopy (SEM-EDX) at the Faculty of Textile Technology, (ii) X-ray Fluorescence Spectroscopy (XRF) at the Croatian Conservation Institute and (iii) Particle Induced X-ray Spectroscopy (PIXE) at the Ruđer Bošković Institute Tandem Accelerator Facility using ion micro beam. Rutherford Backscattering Spectroscopy (RBS) was performed as well on selected samples. SEM-EDX investigations of cross-sections along with the surfaces were also performed. In this work we report and discuss the results obtained by the three X-ray methods and RBS for major (gold, silver, copper) and minor elements on different threads like stripes, wires and "srma" (metal thread wrapped around textile yarn).
The non-destructive identification of early Chinese porcelain by PIXE
NASA Astrophysics Data System (ADS)
Cheng, H. S.; Zhang, Z. Q.; Zhang, B.; Yang, F. J.
2004-06-01
PIXE is used for the non-destructive differentiation of early precious Chinese blue and white porcelain made in Yuan (AD 1206-1368), Ming (AD 1368-1644) Dynasty in Jingdezhen from imitations. Also, ancient celadon made in Song Dynasty (AD 960-1279) is identified by measuring the trace elements contained in the glazes.
Effects of 1,1-Dimethylpiperidinium Chloride on the Pests and Allelochemicals of Cotton and Pecan.
P. A. Hedin; J. N. Jenkins; J. C. McCarty; J. E. Mulrooney; W. L. Parrott; A. Borazjani; C. H. Graves; T. H. Filer
1984-01-01
The growth regulator, PIX (mepiquat chloride - 1,1-dimethyl-piperdinium chloride), when applied to cotton (Gossypium hirsutum L.) and pecan (Carya illinoensis Koch), caused internode shortening. PIX did not elicit an increase in resistance in cotton to the tobacco budworm (Heliothis virescens (Fab.)], or in pecan...
NASA Astrophysics Data System (ADS)
Caragiulo, P.; Dragone, A.; Markovic, B.; Herbst, R.; Nishimura, K.; Reese, B.; Herrmann, S.; Hart, P.; Blaj, G.; Segal, J.; Tomada, A.; Hasi, J.; Carini, G.; Kenney, C.; Haller, G.
2015-05-01
ePix10k is a variant of a novel class of integrating pixel ASICs architectures optimized for the processing of signals in second generation LINAC Coherent Light Source (LCLS) X-Ray cameras. The ASIC is optimized for high dynamic range application requiring high spatial resolution and fast frame rates. ePix ASICs are based on a common platform composed of a random access analog matrix of pixel with global shutter, fast parallel column readout, and dedicated sigma-delta analog to digital converters per column. The ePix10k variant has 100um×100um pixels arranged in a 176×192 matrix, a resolution of 140e- r.m.s. and a signal range of 3.5pC (10k photons at 8keV). In its final version it will be able to sustain a frame rate of 2kHz. A first prototype has been fabricated and characterized. Performance in terms of noise, linearity, uniformity, cross-talk, together with preliminary measurements with bump bonded sensors are reported here.
Multielemental analyses of isomorphous Indian garnet gemstones by XRD and external pixe techniques.
Venkateswarulu, P; Srinivasa Rao, K; Kasipathi, C; Ramakrishna, Y
2012-12-01
Garnet gemstones were collected from parts of Eastern Ghats geological formations of Andhra Pradesh, India and their gemological studies were carried out. Their study of chemistry is not possible as they represent mixtures of isomorphism nature, and none of the individual specimens indicate independent chemistry. Hence, non-destructive instrumental methodology of external PIXE technique was employed to understand their chemistry and identity. A 3 MeV proton beam was employed to excite the samples. In the present study geochemical characteristics of garnet gemstones were studied by proton induced X-ray emission. Almandine variety of garnet is found to be abundant in the present study by means of their chemical contents. The crystal structure and the lattice parameters were estimated using X-Ray Diffraction studies. The trace and minor elements are estimated using PIXE technique and major compositional elements are confirmed by XRD studies. The technique is found very useful in characterizing the garnet gemstones. The present work, thus establishes usefulness and versatility of the PIXE technique with external beam for research in Geo-scientific methodology. Copyright © 2012 Elsevier Ltd. All rights reserved.
A dual-PIXE tomography setup for reconstruction of Germanium in ICF target
NASA Astrophysics Data System (ADS)
Guo, N.; Lu, H. Y.; Wang, Q.; Meng, J.; Gao, D. Z.; Zhang, Y. J.; Liang, X. X.; Zhang, W.; Li, J.; Ma, X. J.; Shen, H.
2017-08-01
Inertial Confinement Fusion (ICF) is one type of fusion energy research which could initiate nuclear fusion reactions through heating and compressing thermonuclear fuel. Compared to a pure plastic target, Germanium doping into the CH ablator layer by Glow Discharge Polymer (GDP) technique can increase the ablation velocity and the standoff distance between the ablation front and laser-deposition region. During target fabrication process, quantitative doping of Ge should be accurately controlled. Particle Induced X-ray Emission Tomography (PIXE-T) can make not only quantification of the concentration, but also reconstruction of the spatial distribution of doped element. The Si (Li) detector for PIXE tomography technique had a disadvantage of low counting rate. To make up this deficiency, another detector of Si (Li) with the same configuration positioned at the opposite side with the same detective angle 135° have been implemented. Simultaneously acquired elemental maps of Ge obtained using two detectors may be different because of the X-ray absorption along the X-ray exit route in the target. In this paper, the X-ray detection efficiency is drastically improved by this dual-PIXE tomography system.
NASA Astrophysics Data System (ADS)
Pogrebnjak, A. D.; Beresnev, V. M.; Bondar', A. V.; Kaverin, M. V.; Ponomarev, A. G.
2013-10-01
(Ti-Zr-Hf-V-Nb)N multicomponent nanostructured coatings with thickness of 1.0-1.4 μm synthesized by the method of cathode arc-vapor deposition at temperatures of 250-300°С are investigated by various mutually complementary methods of elemental structural analysis using slow positron beams (SPB), proton microbeam based particle-induced x-ray emission (μ-PIXE), energy-dispersive x-ray spectroscopy (EDS) and scanning electron microscopy (SEM) analyses based on electron micro- and nanobeams, x-ray diffraction (XRD) method of phase structural analysis, and the "a-sin2φ" method of measuring a stressed-strained state (x-ray tensometry). The elemental composition, microstructure, residual stress in nanograins, profiles of defect and atom distributions with depth and over the coating surface in 3D-representation are studied for these coatings, and their phase composition, severely strained state, and composition of coatings before and after annealing at Tann = 600°С for annealing time τ = 30 min are investigated. It is demonstrated that the oxidation resistance of the examined coatings can be significantly increased by high-temperature annealing that leads to the formation of elastic severely strained compression state of the coating. Redistribution of elements and defects, their segregation near the interface boundaries and around grains and subgrains in the process of thermostimulated diffusion, and termination of spinodal segregation without considerable change of the average nanograin size are revealed.
PIXE Analysis of Artificial Turf
NASA Astrophysics Data System (ADS)
Conlan, Skye; Chalise, Sajju; Porat, Zachary; Labrake, Scott; Vineyard, Michael
2017-09-01
In recent years, there has been debate regarding the use of the crumb rubber infill in artificial turf on high school and college campuses due to the potential presence of heavy metals and carcinogenic chemicals. We performed Proton-Induced X-Ray Emission (PIXE) analysis of artificial turf infill and blade samples collected from high school and college campuses around the Capital District of NYS to search for potentially toxic substances. Crumb rubber pellets were made by mixing 1g of rubber infill and 1g of epoxy. The pellets and the turf blades were bombarded with 2.2 MeV proton beams from a 1.1-MV tandem Pelletron accelerator in the Union College Ion-Beam Analysis Laboratory and x-ray energy spectra were collected with an Amptek silicon drift detector. We analyzed the spectra using GUPIX software to determine the elemental concentrations of the samples. The turf infill showed significant levels of Ti, Fe, Co, Ni, Cu, Zn, Br, and Pb. The highest concentration of Br in the crumb rubber was 1500 +/-100 ppm while the highest detectable amount of Pb concentration was 110 +/-20 ppm. The artificial turf blades showed significant levels of Ti, Fe, and Zn with only the yellow blade showing concentrations of V and Bi.
Phosphorylation of tyrosine 285 of PAK1 facilitates βPIX/GIT1 binding and adhesion turnover
Hammer, Alan; Oladimeji, Peter; De Las Casas, Luis E.; Diakonova, Maria
2015-01-01
The p21-activated serine-threonine kinase (PAK1) regulates cell motility and adhesion. We have previously shown that the prolactin (PRL)-activated tyrosine kinase JAK2 phosphorylates PAK1 in vivo and in vitro and identified tyrosines 153, 201, and 285 in PAK1 as sites of JAK2 tyrosyl phosphorylation. Here, we further investigate the role of the tyrosyl phosphorylated PAK1 (pTyr-PAK1) in regulation of cell adhesion. We use human breast cancer T47D cell lines that stably overexpress PAK1 wild type or PAK1 Y3F mutant in which these 3 JAK2 phosphorylation sites were mutated to phenylalanine. We demonstrate that PRL/JAK2-dependent phosphorylation of these tyrosines promotes a motile phenotype in the cells upon adhesion, participates in regulation of cell adhesion on collagen IV, and is required for maximal PAK1 kinase activity. Down-regulation of PAK1 abolishes the effect of PAK1 on cell adhesion. We show that the tyrosyl phosphorylation of PAK1 promotes PAK1 binding to β-PAK1-interacting guanine-nucleotide exchange factor (βPIX) and G protein-coupled receptor kinase-interacting target 1 (GIT1), phosphorylation of paxillin on Ser273, and formation and distribution of adhesion complexes. Using phosphospecific antibodies (Abs) directed to single phosphorylated tyrosines on PAK1, we identified Tyr285 as a site of PRL-dependent phosphorylation of PAK1 by JAK2. Furthermore, using PAK1 Y285F mutant, we provide evidence for a role of pTyr285 in cell adhesion, enhanced βPIX/GIT1 binding, and adhesion turnover. Our immunohistochemistry analysis demonstrates that pTyr285- PAK1 may modulate PAK1 signaling during tumor progression.—Hammer, A., Oladimeji, P., De La Casas, L. E., Diakonova, M. Phosphorylation of tyrosine 285 of PAK1 facilitates bPIX/GIT1 binding and adhesion turnover. PMID:25466889
NASA Astrophysics Data System (ADS)
Adler, J.; Harrison, T. N.; Bell, J. F., III; Mayer, D. P.
2017-12-01
The layered fan-shaped sedimentary deposit at the terminus of Hypanis Valles has been classified by some as an ancient delta marking the presence of a sea in Chryse Planitia, Mars. The deposit's age is estimated to be 3.6 Ga based on crater counts in the upstream catchment. We further our research on the Hypanis deposit and its relative age by analyzing digital terrain models and high-resolution orbital images of two key study areas: Lederberg crater rim and the distal island deposits. We constructed a 2 m/pix digital terrain model from our requested HiRISE stereo images (0.5 m/pix) of the Lederberg rim northwest of Hypanis, as well as a 24 m/pix digital terrain model from CTX stereo images (6 m/pix) of the island structures northeast of Hypanis. Both terrain models were controlled to MOLA shot data. We added these elevation models to a regional elevation mosaic in order to assess stratigraphy. We found that the Lederberg crater rim has polygonally fractured units, consistent with those in the plains near Hypanis, as well as an example of a distinct mildly sinuous ridge with smooth cones along its profile. We hypothesize that the formation of rounded cones in this region of Xanthe Terra near Hypanis is related to the presence of wrinkle ridges and degraded crater rims. Furthermore, we investigate whether these cones are the youngest geologic formations in the region, postdating the aqueous periods in which the delta and hydrovolcanic cones were formed. We also analyzed the elevation profiles of potential deltaic distal island deposits, and found that some islands are likely part of the main lobe of Hypanis, while others more closely match the chaos units to the east. From our analysis, it is unlikely that the large northern island was once part of the Hypanis deposit. Rather, a larger laterally continuous unit likely once draped the region post-Hypanis formation and has subsequently been eroded.
Standardization of proton-induced x-ray emission technique for analysis of thick samples
NASA Astrophysics Data System (ADS)
Ali, Shad; Zeb, Johar; Ahad, Abdul; Ahmad, Ishfaq; Haneef, M.; Akbar, Jehan
2015-09-01
This paper describes the standardization of the proton-induced x-ray emission (PIXE) technique for finding the elemental composition of thick samples. For the standardization, three different samples of standard reference materials (SRMs) were analyzed using this technique and the data were compared with the already known data of these certified SRMs. These samples were selected in order to cover the maximum range of elements in the periodic table. Each sample was irradiated for three different values of collected beam charges at three different times. A proton beam of 2.57 MeV obtained using 5UDH-II Pelletron accelerator was used for excitation of x-rays from the sample. The acquired experimental data were analyzed using the GUPIXWIN software. The results show that the SRM data and the data obtained using the PIXE technique are in good agreement.
Minkin, J.A.; Chao, E.C.T.; Blank, Herma; Dulong, F.T.
1987-01-01
The PIXE (proton-induced X-ray emission) microprobe can be used for nondestructive, in-situ analyses of areas as small as those analyzed by the electron microprobe, and has a sensitivity of detection as much as two orders of magnitude better than the electron microprobe. Preliminary studies demonstrated that PIXE provides a capability for quantitative determination of elemental concentrations in individual coal maceral grains with a detection limit of 1-10 ppm for most elements analyzed. Encouraged by the earlier results, we carried out the analyses reported below to examine trace element variations laterally (over a km range) as well as vertically (cm to m) in the I and J coal beds in the Upper Cretaceous Ferron Sandstone Member of the Mancos Shale in central Utah, and to compare the data with the data from two samples of eastern coals of Pennsylvanian age.
PIXE analysis of tumors and localization behavior of a lanthanide in nude mice
NASA Astrophysics Data System (ADS)
Chang, Pei-Jiun; Yang, Czau-Siung; Chou, Ming-Ji; Wei, Chau-Chin; Hsu, Chu-Chung; Wang, Chia-Yu
1984-04-01
We have used particle induced X-ray emission (PIXE) to analyze the elemental compositions and uptakes of a lanthanide, yttrium in this report, in tumors and normal tissues of nude mice. A small amount of yttrium nitrate was injected into nude mice with tumors. Samples of normal and malignant tissues taken from these mice were bombarded by the 2 MeV proton beam from a 3 MeV Van de Graaff accelerator with a Ge detector system to determine the relative elemental compositions of tissues and the relative concentrations of yttrium taken up by these tissues. We found that the uptakes of yttrium by tumors were at least five times more than those by normal tissues. Substantial differences were often observed between the trace element weight (or concentration) pattern of the cancerous and normal tissues. The present result is compared with human tissues.
PIXE and ICP-MS Analysis of Andrographis Paniculata Medicinal Plant
NASA Astrophysics Data System (ADS)
Chandrasekhar Rao, J.; Naidu, B. G.; Sarita, P.; Srikanth, S.; Naga Raju, G. J.
2017-08-01
The concentrations of elements Li, Be, Al, Cl, K, Ca, Ti, V, Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Br, Rb, Sr, Ag, Cd, Ba, Pb and U in Andrographis Paniculata medicinal plant used in the treatment of Diabetes Mellitus were determined by using Particle Induced X-ray Emission (PIXE) and Inductively Coupled Plasma Mass Spectroscopy (ICP-MS) techniques. This plant was collected from four different geographical locations in Andhra Pradesh, India in order to assess the regional variation of elemental concentrations. Appreciable levels of K, Ca, Cr, Mn, Cu and Zn determined in this plant can be correlated to the antidiabetic property of Andrographis Paniculata since these elements are known to regulate and potentiate insulin action. Presence of toxic elements As, Cd and Pb necessitates the adoption of precautionary measures while prescribing dosage of the herbal medicine prepared from this plant for the treatment diabetes mellitus.
NASA Astrophysics Data System (ADS)
Olabanji, S. O.; Ige, A. O.; Mazzoli, C.; Ceccato, D.; Ajayi, E. O. B.; De Poli, M.; Moschini, G.
2005-10-01
Accelerator-based technique of PIXE was employed for the determination of the elemental concentration of an industrial mineral, talc. Talc is a very versatile mineral in industries with several applications. Due to this, there is a need to know its constituents to ensure that the workers are not exposed to health risks. Besides, microscopic tests on some talc samples in Nigeria confirm that they fall within the BP British Pharmacopoeia standard for tablet formation. However, for these samples to become a local source of raw material for pharmaceutical grade talc, the precise elemental compositions should be established which is the focus of this work. Proton beam produced by the 2.5 MV AN 2000 Van de Graaff accelerator at INFN, LNL, Legnaro, Padova, Italy was used for the PIXE measurements. The results which show the concentration of different elements in the talc samples, their health implications and metabolic roles are presented and discussed.
Volatility in the lunar crust: Trace element analyses of lunar minerals by PIXE proton microprobe
NASA Technical Reports Server (NTRS)
Norman, M. D.; Griffin, W. L.; Ryan, C. G.
1993-01-01
In situ determination of mineral compositions using microbeam techniques can characterize magma compositions through mineral-melt partitioning, and be used to investigate fine-grained or rare phases which cannot be extracted for analysis. Abundances of Fe, Mn, Sr, Ga, Zr, Y, Nb, Zn, Cu, Ni, Se, and Sb were determined for various mineral phases in a small number of lunar highlands rocks using the PIXE proton microprobe. Sr/Ga ratios of plagioclase and Mn/Zn ratios of mafic silicates show that the ferroan anorthosites and Mg-suite cumulates are depleted in volatile lithophile elements to about the same degree compared with chondrites and the Earth. This links the entire lunar crust to common processes or source compositions. In contrast, secondary sulfides in Descartes breccia clasts are enriched in chalcophile elements such as Cu, Zn, Ni, Se, and Sb, and represent a potential resource in the lunar highlands.
NASA Astrophysics Data System (ADS)
Fleming, S. J.; Swann, C. P.
1992-02-01
The early 9th century A.D. trade links between China's Tang dynasty and the Western world, by land along the caravan routes of the Silk Road and by sea via India and the Gulf, encouraged a taste for many kinds of Chinese ceramics among the affluent societies of the Islamic empire. Using PIXE analysis to determine the primary composition and minor element patterns of the clay fabrics of a wide range of pottery recovered from the Islamic city of Siraf (in southern Iran), we have established clear differences between Chinese wares imported to that region and a variety of imitative wares of local origin. Parallels and contrasts are drawn between our data and those obtained by Chinese scholars in recent years for the products of various Tang kiln sites, particularly for a series of distinctive stonewares from Tongguan (Hunan province).
PIXE-PIGE analysis of teeth from children with and without cystic fibrosis
NASA Astrophysics Data System (ADS)
Cua, Florence T.
1990-04-01
Proton-induced X-ray emission (PIXE) and proton-induced gamma emission (PIGE) were used to analyze Ca, Sr, Fe, Zn, Cu and F, Na, P, Mg respectively in teeth of children with and without cystic fibrosis. The accelerators used were the 3 MeV proton Van de Graaff accelerator at the Brookhaven National Laboratory, NY, USA for the first run and the 8 MV FN-tandem Van de Graaff accelerator at the Nuclear Physics Laboratory, Rutgers University, NJ, USA producing a 4 MeV proton beam for the second and third run. Description of the experimental setup, and the data acquisition system are described in the text. A summary of the results on element concentration as a function of types of teeth and correlation studies are in the text and in F.T. Cua, Ph.D. Thesis, Rutgers Univ. (1989).
Pettengell, Ruth; Coiffier, Bertrand; Egorov, Anton; Singer, Jack; Sivcheva, Lilia
2018-06-01
Pixantrone is recommended in relapsed and refractory non-Hodgkin lymphoma (NHL) or heavily pretreated NHL patients. Its conditional approval in Europe was based on results from the open-label, randomized, phase 3 PIX301 study, comparing pixantrone monotherapy with physician's choice of treatment in 140 patients with relapsed or refractory aggressive NHL. This post-hoc analysis of the PIX301 study investigated possible correlations between patient characteristics and clinical response in 17 patients (24%) treated with pixantrone who achieved a complete response (CR) or an unconfirmed complete response (CRu) at study end. These patients (10 male and 7 female) had a median age of 61 (range 41-75) years, and the most common diagnoses were diffuse large B-cell lymphoma (n = 10) and transformed indolent lymphoma (n = 4). Most had received two prior lines of therapy (n = 12). There was wide variation in the time from diagnosis to study entry (219-4777 days). Among the 17 patients who achieved a CR/CRu with pixantrone, 6 had stable or progressive disease as a response to their last regimen, 7 had a partial response, and 4 had a CR/CRu. Four patients from the pixantrone group survived without progression for more than 400 days. Prior response to previous therapies did not appear to affect long-term response to pixantrone. These observations suggest that pixantrone monotherapy in patients with multiply relapsed or refractory aggressive NHL who had received at least two prior therapies can be associated with durable responses and long-term remission, and this may be unrelated to the clinical response to the last therapy.
NASA Astrophysics Data System (ADS)
Zucchiatti, Alessandro; Alonso, Ursula; Lemasson, Quentin; Missana, Tiziana; Moignard, Brice; Pacheco, Claire; Pichon, Laurent; Camarena de la Mora, Sandra
2014-08-01
A series of granite samples (Grimsel and Äspö) enriched by sorption with natU (10-3 M, 10-4 M, 10-5 M in solution) and La (10-3 M, 10-4 M in solution) has been scanned by PIXE over a surface of 1920 × 1920 mm2 together with non-enriched Grimsel and Äspö granites and a glass standard. An assessment of minimum detection limits, MDL's, for several elements has been performed with the use of standard materials. Due to mapping and the high sensitivity of the new AGLAE detection system, U levels around 30 ppm can be detected from the whole PIXE spectrum (one low energy detector and four summed filtered detectors) while U reach grains, inhomogeneously distributed over the surface can be clearly identified through the multi elemental maps and analyzed separately. Even the nominally enriched samples have La levels below the MDL, probably because precipitation of the element (and not adsorption) mostly took place, and precipitates were eliminated after surface cleaning carried out before PIXE analyses. A multi detector system that implies a PIXE detection solid angle much wider than in any other similar set-up (a factor of 2-5); a higher events selectivity, given by the possibility of filtering individually up to 4 PIXE detectors; a double RBS detector, the new Ion Beam Induced Luminescence (IBIL) spectrometry and gamma spectrometry. Full mapping capability in air, assisted by a powerful event by event reconstruction software. These features allow lower Minimum Detection Limits (MDL) which are highly beneficial to the analysis of cultural heritage objects, meaning generally a reduction of irradiation time. Paintings will then be studied without any damage to the pigments that have color change tendencies which is a major drawback of the previous system. Alternatively they could allow an increase in information collected at equal time, particularly considering the detector's fast response and therefore the potential for high beam currents when sample damage can be tolerated.This kind of set-up should be advantageous for the detection of elements that are present in a geological, archaeological or artistic samples to the level of a few tens ppm. This is true in particular for the rare earths which are relevant to the provenance attribution of various classes of cultural heritage objects (clays, glasses, …) and the actinides which are relevant in very specific and highly impacting dating problems and, more generally, critical environmental elements with special reference to the radionuclide mobility in deep geological formations hosting radioactive waste [2]. Geological materials are highly heterogeneous and consequently their retention of contaminants is heterogeneous as well. In this frame, the capabilities of the AGLAE set-up would allow an improved characterization of natural heterogeneous rock, detecting the presence of the elements of interest (actinides and rare earth) at concentration levels of tens of ppm. This provides a better definition of the initial system, avoiding biased interpretation of the retention properties of the material for the analysis of possible contamination. Additionally, if lower detection limits were achieved, new perspectives to evaluate retention of low solubility contaminants in a wider range of geochemical conditions would be opened.A glass standard and a series of reference granite samples (Grimsel and Äspö), either enriched by sorption with natU and La or kept natural, have been scanned by PIXE at the New-AGLAE detection system, to test measurement protocols and assess the MDL's allowed by the five detectors system.
NASA Technical Reports Server (NTRS)
Blake, D. F.; Sarrazin, P.; Thompson, Kathleen
2017-01-01
The MapX imaging X-ray spectrometer is described and Monte Carlo modeling is used to show the efficacy of 244-Cm radioisotope sources in detecting and quantifying the biogenic elements in ices on Ocean Worlds such as Europa.
Chemistry of Airborne Particulate Matter in the Western Plains of Texas Using PIXE Analysis
USDA-ARS?s Scientific Manuscript database
Aerosol samples on polycarbonate filters were collected daily (for 24 hour periods) over several years in Lubbock, Reese Center, and Big Spring in the Southern High Plains region of western Texas, a region known for frequent dust storms. Twenty-seven filter samples representing a variety of particle...
Heavy metals in the atmosphere coming from a copper smelter in Chile
NASA Astrophysics Data System (ADS)
Romo-Kröger, C. M.; Morales, J. R.; Dinator, M. I.; Llona, F.; Eaton, L. C.
The Chilean mine El Teniente is the world's largest underground copper mine. It operates a giant smelter at Caletones (34° 7' S, 70° 27' W) and we have found it is the major source of air contamination in the region. In August 1991 a special circumstance occurred due to a labor strike, with total cessation of activities. A time series analysis of airborne particles collected at a site about 13 km from the smelter was performed in a period including the strike. The PIXE method and other techniques were used to analyse fine (<2.5 μm) and coarse (2.5-15 μm) particles on Nuclepore filters. S, Cu, Zn and As were quite enriched in normal working periods relative to the strike period. Elemental characterization of soil samples by radioactive source analysis demonstrated that this group of elements did not come from airborne soil dust. Cluster analyses of the interelement correlation matrices, resulting from PIXE data, showed one group (Si, K, Ca, Fe) with main origin in soil and another group (S, Cu, Zn, As) coming from the copper smelter.
Proton Induced X-Ray Emission (PIXE): Determining the Concentration of Samples
NASA Astrophysics Data System (ADS)
McCarthy, Mallory; Rodriguez Manso, Alis; Pajouhafsar, Yasmin; J Yennello, Sherry
2017-09-01
We used Proton Induced X-ray Emission (PIXE) as an analysis technique to determine the composition of samples, in particular, the elemental constituents and the concentrations. Each of the samples are bombarded with protons, which in result displaces a lower level electron and causes a higher level electron to fall into its place. This displacement produces characteristic x-rays that are `fingerprints' for each element. The protons supplied for the bombardment are produced and accelerated by the K150 proton beam in the Cyclotron Institute at Texas A&M University. The products are detected by three x-ray detectors: XR-100CR Si-PIN, XR-100SDD, and XR-100T CdTe. The peaks of the spectrum are analyzed using a software analysis tool, GUPIXWIN, to determine the concentration of the known elements of each particular sample. The goals of this work are to test run the Proton Induced X-Ray Emission experimental set up at Texas A&M University (TAMU) and to determine the concentration of thin films containing KBr given by the TAMU Chemical Engineering Department.
Analysis of Venetian-type glass fragments from the ancient city of Lezha (Albania)
NASA Astrophysics Data System (ADS)
Šmit, Ž.; Stamati, F.; Civici, N.; Vevecka-Priftaj, A.; Kos, M.; Jezeršek, D.
2009-08-01
A series of glasses excavated in the Albanian city of Lezha (ancient Lissos) were analyzed by the combined PIXE-PIGE method in air and by source-excited XRF. The analysis revealed two types of glass that can be identified as façon de Venise glass and its subsequent younger phase, produced by chemically purer components and using As 2O 3 as decolorant.
Ion Beam Facility at the University of Chile; Applications and Basic Research
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miranda, P. A.; Morales, J. R.; Cancino, S.
2010-08-04
The main characteristics of the ion beam facility based on a 3.75 MeV Van de Graaff accelerator at the University of Chile are described at this work. Current activities are mainly focused on the application of the Ion Beam Analysis techniques for environmental, archaeological, and material science analysis. For instance, Rutherford Backscattering Spectrometry (RBS) is applied to measure thin gold film thickness which are used to determine their resistivity and other electrical properties. At this laboratory the Proton Induced X-Ray Emission (PIXE) and Proton Elastic Scattering Analysis (PESA) methodologies are extensively used for trace element analysis of urban aerosols (Santiago,more » Ciudad de Mexico). A similar study is being carried out at the Antarctica Peninsula. Characterization studies on obsidian and vitreous dacite samples using PIXE has been also perform allowing to match some of these artifacts with geological source sites in Chile.Basic physics research is being carried out by measuring low-energy cross section values for the reactions {sup 63}Cu(d,p){sup 64}Cu and {sup Nat}Zn(p,x){sup 67}Ga. Both radionuclide {sup 64}Cu and {sup 67}Ga are required for applications in medicine. Ongoing stopping power cross section measurements of proton and alphas on Pd, Cu, Bi and Mylar are briefly discussed.« less
Ion Beam Facility at the University of Chile; Applications and Basic Research
NASA Astrophysics Data System (ADS)
Miranda, P. A.; Morales, J. R.; Cancino, S.; Dinator, M. I.; Donoso, N.; Sepúlveda, A.; Ortiz, P.; Rojas, S.
2010-08-01
The main characteristics of the ion beam facility based on a 3.75 MeV Van de Graaff accelerator at the University of Chile are described at this work. Current activities are mainly focused on the application of the Ion Beam Analysis techniques for environmental, archaeological, and material science analysis. For instance, Rutherford Backscattering Spectrometry (RBS) is applied to measure thin gold film thickness which are used to determine their resistivity and other electrical properties. At this laboratory the Proton Induced X-Ray Emission (PIXE) and Proton Elastic Scattering Analysis (PESA) methodologies are extensively used for trace element analysis of urban aerosols (Santiago, Ciudad de Mexico). A similar study is being carried out at the Antarctica Peninsula. Characterization studies on obsidian and vitreous dacite samples using PIXE has been also perform allowing to match some of these artifacts with geological source sites in Chile. Basic physics research is being carried out by measuring low-energy cross section values for the reactions 63Cu(d,p)64Cu and NatZn(p,x)67Ga. Both radionuclide 64Cu and 67Ga are required for applications in medicine. Ongoing stopping power cross section measurements of proton and alphas on Pd, Cu, Bi and Mylar are briefly discussed.
Synchrotron and ion beam studies of the bone-cartilage interface
NASA Astrophysics Data System (ADS)
Bradley, D. A.; Kaabar, W.; Gundogdu, O.; Farquharson, M. J.; Janousch, M.; Bailey, M.; Jeynes, C.
2010-07-01
The divalent cations Ca, P and Zn have been reported to play an important role in the normal growth and remodelling of articular cartilage and subchondral bone and in the degenerative and inflammatory processes associated with osteoarthritis (OA). In particular, they act as co-factors of a class of enzymes known as metalloproteinases, believed to be active during the initiation, progress and remodelling processes associated with the disease. The relative presence of cations and anions, in particular the ions Na 2+ and Cl -, is also intimately associated with the fixed charge density (FCD) of cartilage, neutralizing the highly charged structure associated with for instance chondroitin sulphate. Finally, structural components of bone can be expected to result from dietary intake, yielding for instance strontium apatite and fluorapatite that form inclusions in the calcium hydroxyapatite of bone. In the present investigation, thin sections of articular cartilage affected by OA have been examined using a combination of physical techniques: low energy synchrotron micro X-ray fluorescence (μ-SXRF), micro proton induced X-ray emission (μ-PIXE) and micro proton-induced gamma emission (μ-PIGE), primarily to investigate the distribution of essential cations and anions. The combination of these physical techniques offers the ability to make comprehensive assessment of the elemental content of such tissues, simultaneous mappings of a range of relatively low atomic number ions being obtained over quite large areas (˜few mm 2). Such capability has only become a realistic prospect in recent times.
Use of different spectroscopic techniques in the analysis of Roman age wall paintings.
Agnoli, Francesca; Calliari, Irene; Mazzocchin, Gian-Antonio
2007-01-01
In this paper the analysis of samples of Roman age wall paintings coming from: Pordenone, Vicenza and Verona is carried out by using three different techniques: energy dispersive x-rays spectroscopy (EDS), x-rays fluorescence (XRF) and proton induced x-rays emission (PIXE). The features of the three spectroscopic techniques in the analysis of samples of archaeological interest are discussed. The studied pigments were: cinnabar, yellow ochre, green earth, Egyptian blue and carbon black.
A comprehensive experimental characterization of the iPIX gamma imager
NASA Astrophysics Data System (ADS)
Amgarou, K.; Paradiso, V.; Patoz, A.; Bonnet, F.; Handley, J.; Couturier, P.; Becker, F.; Menaa, N.
2016-08-01
The results of more than 280 different experiments aimed at exploring the main features and performances of a newly developed gamma imager, called iPIX, are summarized in this paper. iPIX is designed to quickly localize radioactive sources while estimating the ambient dose equivalent rate at the measurement point. It integrates a 1 mm thick CdTe detector directly bump-bonded to a Timepix chip, a tungsten coded-aperture mask, and a mini RGB camera. It also represents a major technological breakthrough in terms of lightness, compactness, usability, response sensitivity, and angular resolution. As an example of its key strengths, an 241Am source with a dose rate of only few nSv/h can be localized in less than one minute.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dolan, Cheryl E.
The research described in this dissertation consists of four major areas: (1) sequence analysis of protamine 2 from Muroid rodents to identify potential zinc-binding domain(s) of protamine 2; (2) structural studies of the protamine 2-zinc complex from Syrian Gold hamster sperm and spermatids to elucidate the role of zinc during spermiogenesis; (3) structural studies of an unique protamine 2-zinc complex from chinchilla sperm; and (4) Nuclear Magnetic Resonance (NMR) studies of soluble complexes of hairpin oligonucleotides with synthetic arginine-rich peptides or protamine 1 isolated from bull sperm. First, zinc was quantitated in spermatids and sperm by Proton-Induced X-ray Emission (PIXE)more » to determine whether zinc is present in the early stages of spermiogenesis. The PIXE results revealed the zinc content varies proportionately with the amount of protamine 2 in both spermatid and sperm nuclei. An exception was chinchilla sperm containing twice the amount of protamine 2 than zinc. Further analyses by PIXE and X-ray Absorption Spectroscopy (XAS) of zinc bound to protamines isolated from hamster sperm confirmed the majority of the zinc is bound to protamine and identified the zinc ligands of protamine 2 in hamster spermatids and sperm in vivo. These studies established that zinc is bound to the protamine 2 precursor in hamster spermatids and the coordination of zinc by protamine 2 changes during spermiogenesis. Finally, the sequence analysis combined with the XAS results suggest that the zinc-binding domain in protamine 2 resides in the amino-terminus. Similar analyses of chinchilla sperm by XAS were performed to clarify the unusual PIXE results and revealed that chinchilla has an atypical protamine 2-zinc structure. Two protamine 2 molecules coordinate one zinc atom, forming homodimers that facilitate the binding of protamine 2 to DNA and provide an organizational scheme that would accommodate the observed species-specific protamine stoichiometry in mammalian sperm. Based on these results, we propose the binding of zinc to protamine 2 molecules stabilizes a dimerization domain in other mammalian sperm. Future experiments will use the knowledge we gained of the interactions between protamine 1 and DNA from the NMR studies to obtain structural data for the DNA-protamine 2-zinc complex.« less
Detecting changes in the nutritional value and elemental composition of transgenic sorghum grain
NASA Astrophysics Data System (ADS)
Ndimba, R.; Grootboom, A. W.; Mehlo, L.; Mkhonza, N. L.; Kossmann, J.; Barnabas, A. D.; Mtshali, C.; Pineda-Vargas, C.
2015-11-01
We have previously demonstrated that poor digestibility in sorghum can be addressed by using RNA interference (RNAi) to suppress kafirin synthesis. The approach resulted in a twofold improvement in overall protein digestibility levels. In the present study, the effect of this targeted kafirin suppression on other grain quality parameters was investigated. Several significant changes in the proximate composition, amino acid profile and the bulk mineral content were detected. Importantly, the most limiting amino acid, lysine, was significantly increased in the transgenic grains by up to 39%; whilst mineral elements in the bulk, such as sulphur (S) and zinc (Zn) were reduced by up to 15.8% and 21% respectively. Elemental mapping of the grain tissue, using micro-PIXE, demonstrated a significant decrease in Zn (>75%), which was localised to the outer endosperm region, whilst TEM revealed important changes to the protein body morphology of the transgenic grains.
One Click to the Cosmos: The AstroPix Image Archive
NASA Astrophysics Data System (ADS)
Hurt, Robert L.; Llamas, J.; Squires, G. K.; Brinkworth, C.; X-ray Center, Chandra; ESO/ESA; Science Center, Spitzer; STScI
2013-01-01
Imagine a single website that acts as a portal to the entire wealth of public imagery spanning the world's observatories. This is the goal of the AstroPix project (astropix.ipac.caltech.edu), and you can use it today! Although still in a beta development state, this past year has seen the inclusion of thousands of images spanning some of the most prominent observatories in the world, including Chandra, ESO, Galex, Herschel, Hubble, Spitzer, and WISE, with more on the way. The archive is unique as it is built around the Astronomical Visualization Metadata (AVM) standard, which captures the rich contextual information for each image. This ranges from titles and descriptions, to color representations and observation details, to sky coordinates. AVM enables AstroPix imagery to be used in a variety of unique ways that benefit formal and informal education as well as astronomers and the general public. Visitors to Astropix can search the database using simple free-text queries, or use a structured search (similar to "Smart Playlists" found in iTunes, for example). We are also developing public application programming interfaces (APIs) to allow third party software and websites to access the growing content for a variety of uses (planetarium software, museum kiosks, mobile apps, and creative web interfaces, to name a few). Contributing image assets to AstroPix is as easy as tagging the images with the relevant metadata and including the web links to the images in a simple RSS feed. We will cover some of the latest information about tools to contribute images to AstroPix and ways to use the site.
Sizes of particles formed during municipal wastewater treatment.
Lech, Smoczynski; Marta, Kosobucka; Michal, Smoczynski; Harsha, Ratnaweera; Krystyna, Pieczulis-Smoczynska
2017-02-01
Volumetric diameters Dv and specific surface area SpS of sludge particles formed during chemical coagulation and electrocoagulation of sewage were determined. The obtained aggregate-flocs differed substantially in both Dv and SpS values. The differences in Dv and SpS values of the analyzed particles were interpreted based on theoretical models for expanding aggregates. The most uniform particles were formed under exposure to: (a) optimal and maximal doses of PIX, (b) optimal doses of PAX, (c) maximal doses of the Al electro-coagulant. The lowest PIX dose produced the least uniform particles. Sludge aggregates-particles produced under exposure to minimal doses of PIX and the Al electro-coagulant were characterized by the lowest SpS values. Sludge particles coagulated by PAX and the particles formed at higher doses of PIX and the Al electro-coagulant had higher SpS values. The particles formed at all doses of the applied coagulants and electro-coagulants were generally classified into two size ranges: the main range and the secondary range. Most particles belonged to the main size range. An increase in the percentage of colloidal hydroxide particles in sewage sludge increased SpS.
Quantification of indium in steel using PIXE
NASA Astrophysics Data System (ADS)
Oliver, A.; Miranda, J.; Rickards, J.; Cheang, J. C.
1989-04-01
The quantitative analysis of steel for endodontics tools was carried out using low-energy protons (≤ 700 keV). A computer program for a thick-target analysis which includes enhancement due to secondary fluorescence was used. In this experiment the L-lines of indium are enhanced due to the proximity of other elements' K-lines to the indium absorption edge. The results show that the ionization cross section expression employed to evaluate this magnitude is important.
Scanning proton microprobe applied to analysis of individual aerosol particles from Amazon Basin
NASA Astrophysics Data System (ADS)
Gerab, Fábio; Artaxo, Paulo; Swietlicki, Erik; Pallon, Jan
1998-03-01
The development of the Scanning Proton Microprobe (SPM) offers a new possibility for individual aerosol particle studies. The SPM joins Particle Induced X-ray Emission (PIXE) elemental analysis qualities with micrometric spatial resolution. In this work the Lund University SPM facility was used for elemental characterization of individual aerosol particles emitted to the atmosphere in the Brazilian Amazon Basin, during gold mining activities by the so-called "gold shops".
Werner Brandt legacy to PIXE: Past and present perspectives
NASA Astrophysics Data System (ADS)
Lapicki, Gregory
2014-01-01
Inner-shell ionization cross sections used in Particle-Induced X-ray Elemental (PIXE) analyses are routinely calculated in the ECPSSR [W. Brandt, G. Lapicki, Phys. Rev. A 23 (1981) 1717-1729] theory and/or semiempirical formulas scaled to that theory. Thirty years after the passing of Werner Brandt, with recognition of his seminal contributions to other research on positron physics and stopping power problems, the work and articles that progressed into the ECPSSR theory for inner-shell ionization by protons and heavier ions are recalled as Brandt's past legacy to the PIXE community. Applications of the ECPSSR and its evolution into the ECUSAR [G. Lapicki, Nucl. Instr. Meth. B 189 (2002) 8-20] theory over the last three decades are reviewed with perspectives on Brandt's present legacy.
The status of the AMS system at MALT in its 20th year
NASA Astrophysics Data System (ADS)
Matsuzaki, Hiroyuki; Nakano, Chuichiro; Tsuchiya, Yoko S.; Ito, Seiji; Morita, Akira; Kusuno, Haruka; Miyake, Yasuto; Honda, Maki; Bautista VII, Angel T.; Kawamoto, Marina; Tokuyama, Hironori
2015-10-01
MALT (Micro Analysis Laboratory, Tandem accelerator, The University of Tokyo) was designed for a 'highly sensitive and precise elemental and isotopic microanalysis system' using an ion-beam generated by a Pelletron™ 5UD tandem accelerator. Currently, a multi-nuclide AMS (10Be, 14C, 26Al, 36Cl, 129I) system is available and shows good performance in both precision and sensitivity, and the accelerator serves for PIXE, NRA, ERDA/RBS measurements as well. The total operation time of the accelerator has been over 95,000 hours since the start of MALT, 20 years ago. After the Fukushima Daiichi Nuclear Power Plant (FDNPP) accident, many projects related to 129I have been conducted. The retrospective reconstruction of the 131I distribution at the accident from 129I is one of the most important missions for dose evaluation of the residents. The accident-derived 129I is also quite useful as a tracer for the general iodine dynamics in the environment. As a new tool for environmental assessment related to nuclear activity, including the global fallout from past atmospheric nuclear bomb testing, effects from the spent fuel reprocessing plant, and nuclear accidents such as Chernobyl and FDNPP, a 236U-AMS system is now under development.
Lyubenova, Lyudmila; Pongrac, Paula; Vogel-Mikuš, Katarina; Mezek, Gašper Kukec; Vavpetič, Primož; Grlj, Nataša; Regvar, Marjana; Pelicon, Primož; Schröder, Peter
2013-03-15
Understanding the uptake, accumulation and distribution of toxic elements in plants is crucial to the design of effective phytoremediation strategies, especially in the case of complex multi-element pollution. Using micro-proton induced X-ray emission, the spatial distribution of Na, Mg, Al, Si, P, S, Cl, K, Ca, Mn, Fe, Zn, As, Br, Rb, Sr, Cd and Pb have been quantitatively resolved in roots and rhizomes of an obligate wetland plant species, Typha latifolia, treated with a mixture of 100 μM each of As, Cd and Pb, together. The highest concentrations of As, Cd and Pb were found in the roots of the T. latifolia, with tissue-specific distributions. The As was detected in the root rhizodermis, and in the rhizome the majority of the As was within the vascular tissues, which indicates the high mobility of As within T. latifolia. The Cd was detected in the root exodermis, and in the vascular bundle and epidermis of the rhizome. The highest Pb concentrations were detected in the root rhizodermis and exodermis, and in the epidermis of the rhizome. These data represent an essential step in the resolution of fundamental questions in plant ionomics. Copyright © 2013 Elsevier B.V. All rights reserved.
Technology: Computer Applications for Young Users--BumperCar and KidPix
ERIC Educational Resources Information Center
Van Horn, Royal
2004-01-01
There is a lot of software available for young children, but there are not many applications designed especially for them. This situation may be about to change with the release of BumperCar and a new version of KidPix, both of which recently earned awards from MacWorld magazine. In this article, the author describes this new software and how it…
Bioaccumulation characterization of uranium by a novel Streptomyces sporoverrucosus dwc-3.
Li, Xiaolong; Ding, Congcong; Liao, Jiali; Du, Liang; Sun, Qun; Yang, Jijun; Yang, Yuanyou; Zhang, Dong; Tang, Jun; Liu, Ning
2016-03-01
The biosorption mechanisms of uranium on an aerobic bacterial strain Streptomyces sporoverrucosus dwc-3, isolated from a potential disposal site for (ultra-)low uraniferous radioactive waste in Southwest China, were evaluated by using transmission electron microscopy (TEM), energy dispersive X-ray (EDX) analysis, Fourier transform infrared spectroscopy (FT-IR), X-ray photoelectron spectroscopy (XPS), proton induced X-ray emission (PIXE) and enhanced proton backscattering spectrometry (EPBS). Approximately 60% of total uranium at an initial concentration of 10mg/L uranium nitrate solution could be absorbed on 100mg S. sporoverrucosus dwc-3 with an adsorption capacity of more than 3.0mg/g (wet weight) after 12hr at room temperature at pH3.0. The dynamic biosorption process of S. sporoverrucosus dwc-3 for uranyl ions was well described by a pseudo second-order model. S. sporoverrucosus dwc-3 could accumulate uranium on cell walls and within the cell, as revealed by SEM and TEM analysis as well as EDX spectra. XPS and FT-IR analysis further suggested that the absorbed uranium was bound to amino, phosphate and carboxyl groups of the cells. Additionally, PIXE and EPBS results confirmed that ion exchange also contributed to the adsorption process of uranium. Copyright © 2015. Published by Elsevier B.V.
Characterization of the air pollution in the urban area of Madrid
NASA Astrophysics Data System (ADS)
Climent-Font, Aurelio; Swietlicki, Erik; Revuelta, Antonio
1994-03-01
An attempt is made to characterize for the first time the urban pollution of Madrid using the combination of conventional gas measurements and an ion beam analytical technique (PIXE) for aerosol monitoring. Different sets of samples were collected selecting different seasons of the year; winter and summer 1992, and also different sampling times; 3 h and 24 h. A group of 18 elements in the mass range from Si to Pb could be analyzed. Concentration of gases in the air was recorded for the following: CO, NO x, NO 2, SO 2 and C xH y. Four sources contributing to the air pollution were obtained by means of absolute principal component analysis where automotive transport emerges as the dominating one. The combination of aerosol (PIXE) and gas data as input to a receptor model proved to be fruitful for the understanding of the underlying chemical and physical processes governing the observed pollution levels. This is a preliminary study whose results will supply the trends and strategies for a more thorough characterization.
Spectral structure of a polycapillary lens shaped X-ray beam
NASA Astrophysics Data System (ADS)
Gogolev, A. S.; Filatov, N. A.; Uglov, S. R.; Hampai, D.; Dabagov, S. B.
2018-04-01
Polycapillary X-ray optics is widely used in X-ray analysis techniques to create a small secondary source, for instance, or to deliver X-rays to the point of interest with minimum intensity losses [1]. The main characteristics of the analytical devices on its base are the size and divergence of the focused or translated beam. In this work, we used the photon-counting pixel detector ModuPIX to study the parameters for polycapillary focused X-ray tube radiation as well as the energy and spatial dependences of radiation at the focus. We have characterized the high-speed spectral camera ModuPIX, which is a single Timepix device with a fast parallel readout allowing up to 850 frames per second with 256 × 256 pixels and a 55 μm pitch defined by the frame frequency. By means of the silicon monochromator the energy response function is measured in clustering mode by the energy scan over total X-ray tube spectrum.
Total elemental composition analysis of soil samples using the PIXE technique
NASA Astrophysics Data System (ADS)
Bolormaa, Oyuntsetseg; Baasansuren, Jamsranjav; Kawasaki, Katsunori; Watanabe, Makiko; Hattroi, Toshiyuki
2007-09-01
The determination of major and trace element contents in soils was developed by acid digestion method combined with particle-induced X-ray emission spectrometry (PIXE). The digestion of soils was achieved by using nitric acid (HNO3), hydrochloric acid HCl and hydrogen peroxide (H2O2) with repeated additions. A 20 μL aliquot from the digested samples was evaporated on the Nuclepore Track-Etch Membrane and irradiated by the 2.5 MeV proton beam from the single-end type Van de Graaff accelerator. The accuracy of this methodology was estimated based on series of measurements done for a reference material of soil CRM 023-050. The proposed experimental procedure was shown to have good reproducibility of the experimental results. The corresponding limits of detection (LODs) for Na, Mg, Al, P, S, Cl, K, Cr, Mn, Fe, Ni, Cu, Zn, As, Sr, Mo and Cd were estimated. Other soil characteristics such as total carbon (TC) and nitrogen (TN) content, pH and electrical conductivity (EC) were also measured.
NASA Astrophysics Data System (ADS)
Pappalardo, L.; Bracchitta, D.; Palio, O.; Pappalardo, G.; Rizzo, F.
2012-04-01
About 1300 obsidian artefacts coming from various archaeological sites of Sicily were analyzed by using the BSC-XRF (Beam Stability Controlled - X-ray Fluorescence) and PIXE-alpha (Particle Induced X-ray Emission, using low energy alpha particles) portable spectrometers developed at the Landis laboratory at the LNS-INF and IBAM-CNR in Catania (Italy). The portable BSC-XRF system allows the non-destructive analysis of the Rb, Sr, Y, Zr and Nb trace concentrations, which are considered to be characteristic of the obsidian samples and consequently are indicative of the provenance quarries. Quantitative data on Rb, Sr, Y, Zr, Nb trace element concentrations where deduced through the use of a method that makes use of a multi parameter linear regression, previously The portable PIXE-alpha spectrometer allows the quantitative determination of the matrix major elements, from Na to Zn. In the present work the two instrumental devices are presented. The data are from: Milena (Cl), Ustica (Pa), Rocchicella (Ct), Poggio dell'Acquila (Ct), San Marco (Ct), Villaggio del Petraro* (Sr) and Licodia Eubea* (Ct). Results on compositional data for trace elements and major elements allowed to identify Lipari and Pantelleria islands as the only two sources of the analysed samples. Analyses carried out on vitreous artefact found in Rocchicella, showed for the first time that the Palagonite was used as row material. *Preliminary data. Topic of conference: Application of XRS in archaeometry Kind of presentation: oral
External beam pixe programs at the University of California, Davis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eldred, R.A.
A PIXE system in which large or delicate samples are excited by a low-current external proton beam is described. This system has been used to analyze historical printed books and manuscripts, as well as a large variety of archeological artifacts. The steps used to protect the sample from unnecessary beam current are examined. A recent thorough study of the first volume of the Gutenberg 42-line Bible is described in some detail.
The Plasma Interaction Experiment (PIX) description and test program. [electrometers
NASA Technical Reports Server (NTRS)
Ignaczak, L. R.; Haley, F. A.; Domino, E. J.; Culp, D. H.; Shaker, F. J.
1978-01-01
The plasma interaction experiment (PIX) is a battery powered preprogrammed auxiliary payload on the LANDSAT-C launch. This experiment is part of a larger program to investigate space plasma interactions with spacecraft surfaces and components. The varying plasma densities encountered during available telemetry coverage periods are deemed sufficient to determine first order interactions between the space plasma environment and the biased experimental surfaces. The specific objectives of the PIX flight experiment are to measure the plasma coupling current and the negative voltage breakdown characteristics of a solar array segment and a gold plated steel disk. Measurements will be made over a range of surface voltages up to plus or minus kilovolt. The orbital environment will provide a range of plasma densities. The experimental surfaces will be voltage biased in a preprogrammed step sequence to optimize the data returned for each plasma region and for the available telemetry coverage.
Integrated bio-photonics to revolutionize health care enabled through PIX4life and PIXAPP
NASA Astrophysics Data System (ADS)
Jans, Hilde; O'Brien, Peter; Artundo, Iñigo; Porcel, Marco A. G.; Hoofman, Romano; Geuzebroek, Douwe; Dumon, Pieter; van der Vliet, Marcel; Witzens, Jeremy; Bourguignon, Eric; Van Dorpe, Pol; Lagae, Liesbet
2018-02-01
Photonics has become critical to life sciences. However, the field is far from benefiting fully from photonics' capabilities. Today, bulky and expensive optical systems dominate biomedical photonics, even though robust optical functionality can be realized cost-effectively on single photonic integrated circuits (PICs). Such chips are commercially available mostly for telecom applications, and at infrared wavelengths. Although proof-of-concept demonstrations for PICs in life sciences, using visible wavelengths are abundant, the gating factor for wider adoption is limited in resource capacity. Two European pilot lines, PIX4life and PIXAPP, were established to facilitate European R and D in biophotonics, by helping European companies and universities bridge the gap between research and industrial development. Through creation of an open-access model, PIX4life aims to lower barriers to entry for prototyping and validating biophotonics concepts for larger scale production. In addition, PIXAPP enables the assembly and packaging of photonic integrated circuits.
Some new results of PIXE study on Chinese ancient porcelain
NASA Astrophysics Data System (ADS)
Cheng, H. S.; Zhang, B.; Zhu, D.; Yang, F. J.; Sun, X. M.; Guo, M. S.
2005-10-01
This paper reports some new results obtained by PIXE on Chinese ancient porcelain. The first results concern the provenance of blue and white porcelain made during the Tang Dynasty (AD618-907), which are the earliest products found in China. The PIXE experimental results show that they were fired in Huangye Kiln, Gongyi, Henan Province. The chemical composition of the body, white glaze and of the cobalt pigment will be reported. This paper also reports the results for early Chinese blue and white porcelain made under the Yuan dynasty (AD1206-1368) in Jingdezhen, Jiangxi Province. Experimental results show that the chemical composition of the cobalt pigment used by officers and popular are similar. These materials were imported from another country. The local asbolite was used as cobalt pigment material since the early Ming Dynasty (AD1368-1644) in Jingdezhen at folk kiln, and it was used at official kiln until the 16th century.
Use of PIXE-PIGE under variable incident angle for ancient glass corrosion measurements
NASA Astrophysics Data System (ADS)
Weber, G.; Strivay, D.; Martinot, L.; Garnir, H. P.
2002-04-01
Although glass is usually considered as a very stable archaeological material, it can undergo severe degradation. Soda-lime glass, the most common glass throughout ancient times, is particularly sensitive to this problem. The glass surface absorbs moisture from its environment and the contact with CO 2 causes Na 2O and NaOH to convert to Na 2CO 3, which is extremely hygroscopic. The subsequent unstable glass layer can be leached out and causes decomposition of the glass. The non-destructive PIGE-PIXE method of investigation allows detection of this phenomenon even if no visible effect appears. The variable incident angle method is able to discern the depth of the degradation. One aim of such studies is the possible dating or at least fake detecting of archaeological materials. Furthermore, even objects of large size can be investigated with the atmospheric PIGE-PIXE set-up. Some examples of measurements on ancient glass are given.
Developments towards the LHCb VELO upgrade
NASA Astrophysics Data System (ADS)
Cid Vidal, Xabier
2016-09-01
The Vertex Locator (VELO) is a silicon strip detector surrounding the interaction region of the LHCb experiment. The upgrade of the VELO is planned to be installed in 2019-2020, and the current detector will be replaced by a hybrid pixel system equipped with electronics capable of reading out at a rate of 40 MHz. The new detector is designed to withstand the radiation dose expected at an integrated luminosity of 50 fb-1. The detector will be composed of silicon pixel sensors, read out by the VeloPix ASIC that is being developed based on the TimePix/MediPix family. The prototype sensors for the VELO upgrade are being irradiated in five different facilities and the post-irradiation performance is being measured with testbeams, and in the lab. These proceedings present the VELO upgrade and briefly discuss the results of the sensor testing campaign.
NASA Astrophysics Data System (ADS)
Yasuhiro, Matsuda; Katsushi, Okuyama; Hiroko, Yamamoto; Hisanori, Komatsu; Masashi, Koka; Takahiro, Sato; Naoki, Hashimoto; Saiko, Oki; Chiharu, Kawamoto; Hidehiko, Sano
2015-04-01
To prevent the formation of caries and reduce dentin hypersensitivity, sealing materials, either with or without fluoride, are generally applied on the tooth in clinical practice. Application of fluoride-free sealing materials results in the formation of an acid-resistant layer on the tooth surface. On the other hand, fluoride-containing sealing materials might not only form an acid-resistant layer but could possibly further provide fluoride to enhance remineralization and reduce demineralization. In this study, the demineralization prevention ability and fluorine uptake rate in human enamel of fluoride-containing sealing materials ["MS coats F" (MSF)] and fluoride-free sealing materials ("hybrid coats 2" [HI]) were evaluated using an automatic pH cycling system. Each material was applied to the original tooth surface, the cut surfaces were covered with sticky wax, and the automatic pH-cycling system simulated daily acid changes (pH 6.8-4.5) occurring in the oral cavity for 4 weeks. Caries progression was analyzed using transverse microradiography (TMR) taken pre and post the 4 weeks of pH cycling. The fluorine and calcium distributions in the carious lesion in each specimen were evaluated using the proton-induced gamma emission (PIGE) and proton-induced X-ray (PIXE) techniques, respectively. TMR analysis showed that both MSF and HI had a caries-preventing effect after 4 weeks of pH cycling. PIGE/PIXE analysis demonstrated that only MSF resulted in fluoride uptake in the enamel surface. Therefore, MSF can help to form an acid-resistant layer and provide fluoride to the enamel surface. The presence of fluoride on the enamel surface suggested that MSF could prevent demineralization, even if the acid-resistant layer was removed, in clinical settings. The data obtained using the PIGE and PIXE techniques are useful for understanding the benefits of the use of a fluoride-containing sealing material for preventing caries.
A Detailed Analysis of Aerosols Containing Zn, Pb, and Cl from an Industrial Region of Mexico City
NASA Astrophysics Data System (ADS)
Moffet, R. C.; Desyaterik, Y.; Hopkins, R. J.; Tivanski, A. V.; Gilles, M. K.; Shutthanandan, V.; Molina, L. T.; Gonzalez-Abraham, R.; Johnson, K. S.; Mugica, V.; Molina, M. J.; Laskin, A.; Prather, K. A.
2008-12-01
Measurements in the Northern Mexico City Metropolitan Area during the March, 2006 MILAGRO campaign revealed the frequent appearance of particles with a characteristically high content of internally mixed Zn, Pb, Cl, and P. A detailed analysis of the chemical and physical properties of these particles was performed using a complementary combination of aerosol measurement techniques. Single particles were analyzed using Aerosol Time-of-Flight Mass Spectrometry (ATOFMS) and Computer Controlled Scanning Electron Microscopy/Energy Dispersive X-Ray spectroscopy (CCSEM/EDX). Proton Induced X-Ray Emission (PIXE) analysis of bulk aerosol samples provided time-resolved mass concentrations of individual elements. The PIXE measurements indicated that Zn is more strongly correlated with Cl than with any other element and that Zn concentrations are higher than other non-ferrous transition metals. The Zn- and Pb - containing particles have both spherical and non-spherical morphologies. Many metal rich particles had needle-like structures and were found to be composed of ZnO and/or Zn(NO3)2-6H2O as indicated by scanning transmission x-ray microscopy/near edge X-ray absorption spectroscopy (STXM/NEXAFS). The Zn and Pb rich particles were primarily in the submicron size range and internally mixed with elemental carbon. The unique chemical associations most closely match signatures acquired for garbage incineration.
Investigation of titanium dioxide nanoparticles toxicity and uptake by plants
NASA Astrophysics Data System (ADS)
Larue, C.; Khodja, H.; Herlin-Boime, N.; Brisset, F.; Flank, A. M.; Fayard, B.; Chaillou, S.; Carrière, M.
2011-07-01
Nanoparticles (NP) are introduced in a growing number of commercial products and their production may lead to their release in the environment. Plants may be a potential entry point for NP in the food chain. Up to now, results describing NP phytotoxical effects and plant accumulation are scarce and contradictory. To increase knowledge on titanium dioxide NP (TiO2-NPs) accumulation and impact on plants, we designed a study on three plant species, namely wheat (Triticum aestivum), oilseed rape (Brassica napus) and Arabidopsis thaliana. These plants were exposed in hydroponics to a panel of well-characterized TiO2-NPs, with diameters ranging from 12 to 140 nm, either anatase or rutile. Their accumulation in plant tissues is currently being assessed by complementary imaging techniques: scanning electron microscopy (SEM), transmission electron microscopy (TEM), micro-X-ray fluorescence (SR-μ-XRF) imaging and micro-particle induced X-ray emission (μ-PIXE) imaging. Moreover, the impact of TiO2-NP exposure on germination rate, root elongation, dry biomass and evapotranspiration is evaluated. Preliminary results are presented here, with data collected on wheat plants exposed to 12 nm and 25 nm anatase TiO2-NPs. These results show that TiO2-NPs are taken up by plants, and do not significantly alter their germination and root elongation. These results underline the necessity of deeper evaluation of nanoparticle ecotoxicity, and particularly on their interaction with plants.
Possible Overlaps Between Blobs, Grism Apertures, and Dithers
NASA Astrophysics Data System (ADS)
Ryan, R. E.; McCullough, P. R.
2017-06-01
We present a investigation into possible overlaps between the known IR blobs with the grism aperture reference positions and the IR dither patterns. Each aperture was designed to place the science target (e.g. a specific star) on a cosmetically clean area of the IR detector. Similarly, the dither patterns were designed to mitigate cosmetic defects by rarely (or ideally never) placing such targets on known defects. Because blobs accumulate with time, the originally defined apertures and dither patterns may no longer accomplish their goals, it is important to reverify these combinations. We find two potential overlaps between the blob, aperture, and dither combinations, but do not recommend any changes to the current suite of aperture references positions and/or dither patterns for two reasons. First, one of the overlaps occurs with a dither/aperture combination that is seldom used for high-value science operations, but rather more common for wide-field surveys/mosaics. Second, the other overlap is 8.7 pix from a blob that has a fiducial radius of 10 pix, which already represents a very conservative distance. We conclude that a similar analysis should be repeated as new blobs occur, to continue to ensure ideal operations for high-value science targets. The purpose of this report is to document the analysis in order to facilitate its repetition in the future.
μPIXE for a μBrain: The vinegar fly's brain, antenna, sensilla hairs and eye ion concentrations
NASA Astrophysics Data System (ADS)
Reinert, Anja; Barapatre, Nirav; Sachse, Silke; Reinert, Tilo
2011-10-01
The vinegar fly Drosophila melanogaster is used as model organism to study a variety of different scientific purposes. Thus, our laboratory studies the olfactory system by neurobiological experiments. These techniques are often disruptive and need to compensate or exchange the body fluid, the lymph, with an artificial Ringer's solution in defined compartments of the fly. The solution mainly contains Na, Cl, K and Ca and is to keep physiological conditions. Therefore, the knowledge about the ion concentrations in the respective Drosophila lymph is required for a correct mixture of the ions. This paper presents the spatially resolved concentrations of P, S, Cl, K, Ca, Fe, Cu and Zn in lyophilised head cryosections of Drosophila by using quantitative μPIXE at the ion beam facility LIPSION in Leipzig. The PIXE maps enable a detailed analysis of particular regions of interest down to a spatial resolution of 0.5 μm. We quantified the ion concentrations especially in the brain, the antenna and its sensilla hairs acting as the olfactory organ of the fly, in the compound eye and in the mouthparts. The averaged element concentrations of these main compartments are (in descending order): P: 90 mM, K: 81 mM, S: 38 mM, Cl: 18 mM, Ca: 4.9 mM, Fe: 1.4 mM, Zn: 1.2 mM, Cu: 0.06 mM. Certain structures or cavities possess a remarkably high concentration of particular elements and might reflect the different functions of the compartments. An example presented in more detail is the composition of the compound eye. Conclusively, our findings on the ion concentrations might be useful for the mixture of the Drosophila Ringer's solution to ensure physiological conditions in experiments.
The use of nuclear muprobe techniques to study the chemistry of lacustrine sediments and particles
NASA Astrophysics Data System (ADS)
Grime, G. W.; Davison, W.
1993-05-01
The Oxford SPM has been used in two novel studies of lake chemistry: (a) The distribution of dissolved iron in sediment pore waters close to the sediment/water interface has been measured using the novel technique of diffusive equilibration in a thin film (DET). In this technique, which has a spatial resolution of < 1 mm, much less than that of competing techniques (1 cm), a thin layer of polyacrylamide gel is inserted into the sediment and after the rapid equilibration with the pore water, the gel is dried and fixed. The distribution of trace elements can then be measured using mubeam PIXE. Preliminary results have shown for the first time a subsurface maximum of Fe consistent with current theories of Fe dynamics. This paper presents some results obtained using the technique and discusses the limits on resolution and sensitivity, (b) Individual suspended lake particles (predominantly iron oxides and sulphides) have been analysed using point mubeam RBS and PIXE. Of particular interest in this study is the oxidation state of iron rich particles, so RBS with a 1 μm beam was used to determine the Fe: O stoichiometry of single particles. The particles were filtered from a depth of 14 m in Esthwaite Water in the English Lake District and handled in anoxic conditions until evacuation in the SPM sample chamber. Two distinct compositions of iron oxide were determined in clusters of about 5 μm diameter. Analysis by PIXE revealed that FeS was uniformly distributed in the particulate material and that it also contained elevated levels of Cu and Zn. This study was the first to demonstrate directly that discrete clusters of iron oxides are present in black particulate material which is commonly considered to comprise iron sulphides.
NASA Astrophysics Data System (ADS)
Vieira Ferreira, L. F.; Casimiro, T. M.; Colomban, Ph.
2013-03-01
Two sherds representative of the Portuguese faience production of the first and second halves of the 17th century were studied carefully with the use of non-invasive spectroscopies, namely: Ground State Diffuse Reflectance Absorption (GSDR), micro-Raman, Fourier-Transform Infrared (FT-IR), Laser Induced Luminescence (LIL) and Proton Induced X-ray (PIXE). These results were compared with the ones obtained for a Chinese Ming porcelain, Wanli period (16th/beginning of the 17th centuries), which served as an influence for the initial Lisbon's faience production. By combining information of the different non-destructive spectroscopic techniques used in this work, it was possible to conclude that: Co3O4 (Co II and Co III) can be found in the silicate matrix and is the blue pigment in the "Especieiro" sample (1st half of the 17th C.). Cobalt olivine silicate (Co2SiO4, Co II only) was clearly identified as the blue pigment in "Aranhões" sample (2nd half of the17th C.) - 824 cm-1 band in the micro-Raman-spectrum. Cobalt aluminate (CoAl2O4, Co II only) is the blue pigment in the Wanli plate - 203 and 512 cm-1 bands in the micro-Raman spectrum. The blue pigment in the 1st half 17th century of Lisbon's production was obtained by addition of a cobalt ore in low concentrations, which gives no specific Raman signature, because of complete dissolution in the glass. However, in most cases of the 2nd half 17th century, the Raman signature was quite evident, from a cobalt silicate. These findings point to the use of higher temperature kilns in the second case.
NASA Astrophysics Data System (ADS)
Ortega-Feliu, I.; Ager, F. J.; Roldán, C.; Ferretti, M.; Juanes, D.; Scrivano, S.; Respaldiza, M. A.; Ferrazza, L.; Traver, I.; Grilli, M. L.
2017-09-01
This work presents a detailed study of a series of silver plates gilded via electroplating techniques in which the characteristics of the coating gold layers are investigated as a function of the electroplating variables (voltage, time, anode surface and temperature). Some reference samples were coated by radio frequency sputtering in order to compare gold layer homogeneity and effective density. Surface analysis was performed by means of atomic and nuclear techniques (SEM-EDX, EDXRF, PIXE and RBS) to obtain information about thickness, homogeneity, effective density, profile concentration of the gold layers and Au-Ag diffusion profiles. The gold layer thickness obtained by PIXE and EDXRF is consistent with the thickness obtained by means of RBS depth profiling. Electroplated gold mass thickness increases with electroplating time, anode area and voltage. However, electrodeposited samples present rough interfaces and gold layer effective densities lower than the nominal density of Au (19.3 g/cm3), whereas sputtering produces uniform layers with nominal density. These analyses provide valuable information to historians and curators and can help the restoration process of gold-plated silver objects.
NASA Astrophysics Data System (ADS)
Leffa, Daniela Dimer; dos Santos, Carla Eliete Iochims; Debastiani, Rafaela; Amaral, Livio; Yoneama, Maria Lucia; Dias, Johnny Ferraz; Andrade, Vanessa Moraes
2014-01-01
The importance of trace elements in human health is well known and their main source is daily diet. Nowadays, one of the biggest issues is the presence of these micronutrients in levels much higher than required, leading to potential toxic effects. The aim of this work was to investigate the elemental content in organs of mice fed with cafeteria or standard diet using PIXE. Twelve male Swiss mice were divided into two groups: control group (standard chow) and cafeteria group (high-caloric diet). After 17 weeks, samples of different organs (kidney and liver) were collected and prepared for PIXE analysis. The Fe concentration in kidney and liver was statistically higher in animals that received the cafeteria diet (p < 0.001). The Al and Si kidney contents were significantly higher for cafeteria diet in relation to standard diet (p < 0.05). Moreover, the standard diet showed significant differences for Cl and K (p < 0.05) in comparison to cafeteria diet in kidney, and for P, S and Zn (p < 0.005) in liver.
PIXE analysis of airborne particulate matter from Monterrey, Mexico. A first survey
NASA Astrophysics Data System (ADS)
Aldape, F.; Flores M, J.; Díaz, R. V.; Hernández-Méndez, B.; Montoya Z, J. M.; Blanco, E. E.; Fuentes, A. F.; Torres-Martínez, L. M.
1999-04-01
A first survey of elemental contents in airborne particulate matter from Monterrey, Nuevo León, Mexico, was performed using PIXE. This second largest industrial city is located 715 km north of Mexico City, and counts with a population of nearly three million inhabitants in its conurbation. Air pollution in the place comes from a great variety of industries ranging from iron smelters to furniture manufacturing, as well as from fuel combustion in vehicles and industries. This study presents results of elemental contents in airborne particulate matter in two particle size fractions: PM 2.5 and PM 15. The samples were collected during five weeks on working days, Monday-Friday, from 9 December 1996 to 14 January 1997. Two samples a day were collected, 12 h each, night-time and day-time. These first results show local pollution as typical from a large urban area in conjunction with an active industry. Thirteen elements were consistently detected in most of the samples and some episodes due to both industrial and human activities were identified. A general discussion about the results obtained is presented.
Analysis of metals with luster: Roman brass and silver
NASA Astrophysics Data System (ADS)
Fajfar, H.; Rupnik, Z.; Šmit, Ž.
2015-11-01
Non-destructive PIXE analysis using in-air proton beam was used for the studies of earliest brass coins issued during the 1st century BC by Greek cities in Asia Minor, Romans and Celts, and for the studies of plated low grade silver coins of the 3rd century AD. The analysis determined the levels of zinc and important trace elements, notably selenium, which confirms spread of selenium-marked copper from the east. For plating, combined tinning and silvering was identified by the mapping technique for the mid 3rd century AD, which evolved into mere plating by 270 AD.
De Leo, Gianluca; Gonzales, Carol H; Battagiri, Padmaja; Leroy, Gondy
2011-08-01
Autism is a complex neurobiological disorder that is part of a group of disorders known as autism spectrum disorders (ASD). Today, one in 150 individuals is diagnosed with autism. Lack of social interaction and problems with communication are the main characteristics displayed by children with ASD. The Picture Exchange Communication System (PECS) is a communication system where children exchange visual symbols as a form of communication. The visual symbols are laminated pictures stored in a binder. We have designed, developed and are currently testing a software application, called PixTalk which works on any Windows Mobile Smart-phone. Teachers and caregivers can access a web site and select from an online library the images to be downloaded on to the Smart-phone. Children can browse and select images to express their intentions, desires, and emotions using PixTalk. Case study results indicate that PixTalk can be used as part of ongoing therapy.
NASA Astrophysics Data System (ADS)
Bao, Liang-Man; Zhang, Gui-Lin; Zhang, Yuan-Xim; Li, Yan; Lin, Jun; Liu, Wei; Cao, Qing-Chen; Zhao, Yi-Dong; Ma, Chen-Yan; Han, Yong
2009-11-01
The impact of coal-burning emission on sulfur in camphor leaves was investigated using Proton Induced X-ray Emission (PIXE) and synchrotron radiation technique X-ray Absorption Near-Edge Structure (XANES) spectroscopy. The PIXE results show that the sulfur concentrations in the leaves collected at the polluted site are significantly higher than those in controls. The Sulfur XANES spectra show the presence of organic (disulfides, thiols, thioethers, sulfonates and sulfoxides) and inorganic sulfur (sulfates) in the leaves. The inorganic sulfur in the leaves of camphor tree polluted by coal combustion is 15% more than that of the control site. The results suggest that the long-term coal-burning pollution resulted in an enhanced content of the total sulfur and sulfate in the leaves, and the uptake of sulfur by leaves had exceeded the metabolic requirement of plants and the excess of sulfur was stored as SO2-4. It can monitor the sulfur pollution in atmosphere.
Analysis of Greek small coinage from the classic period
NASA Astrophysics Data System (ADS)
Šmit, Ž.; Šemrov, A.
2018-02-01
A series of 25 Greek coins from the 6th to 4th centuries BC was studied by PIXE for their trace element composition, with an aim to discover the origin of their silver ore. The procedure revealed a counterfeited coin, and then concentrated on distinguishing the coins minted from the ore of Laurion on the Attica peninsula and the coins minted from other sources. Linear discriminant analysis based on the impurities and alloying elements of copper, gold, lead and bismuth revealed that discrimination is indeed possible according to a single canonical variable.
Thomas L Eberhardt; Hui Pan
2013-01-01
Gasification of biomass ultimately generates at least one solid byproduct in which the inorganic constituents of the biomass are concentrated. Given the potential for utilization, or issues with disposal, facile methods are needed for determining the compositions of the fly ashes from recently-available gasifier-based bioenergy systems. Proton induced x-ray emission...
NASA Astrophysics Data System (ADS)
Rizzo, G.; Batignani, G.; Benkechkache, M. A.; Bettarini, S.; Casarosa, G.; Comotti, D.; Dalla Betta, G.-F.; Fabris, L.; Forti, F.; Grassi, M.; Lodola, L.; Malcovati, P.; Manghisoni, M.; Mendicino, R.; Morsani, F.; Paladino, A.; Pancheri, L.; Paoloni, E.; Ratti, L.; Re, V.; Traversi, G.; Vacchi, C.; Verzellesi, G.; Xu, H.
2016-07-01
The INFN PixFEL project is developing the fundamental building blocks for a large area X-ray imaging camera to be deployed at next generation free electron laser (FEL) facilities with unprecedented intensity. Improvement in performance beyond the state of art in imaging instrumentation will be explored adopting advanced technologies like active edge sensors, a 65 nm node CMOS process and vertical integration. These are the key ingredients of the PixFEL project to realize a seamless large area focal plane instrument composed by a matrix of multilayer four-side buttable tiles. In order to minimize the dead area and reduce ambiguities in image reconstruction, a fine pitch active edge thick sensor is being optimized to cope with very high intensity photon flux, up to 104 photons per pixel, in the range from 1 to 10 keV. A low noise analog front-end channel with this wide dynamic range and a novel dynamic compression feature, together with a low power 10 bit analog to digital conversion up to 5 MHz, has been realized in a 110 μm pitch with a 65 nm CMOS process. Vertical interconnection of two CMOS tiers will be also explored in the future to build a four-side buttable readout chip with high density memories. In the long run the objective of the PixFEL project is to build a flexible X-ray imaging camera for operation both in burst mode, like at the European X-FEL, or in continuous mode with the high frame rates anticipated for future FEL facilities.
PIEX and neurological diseases
NASA Astrophysics Data System (ADS)
Van Rinsvelt, H. A.; Hurd, R. W.; Kondoro, J. W. A.; Andres, J. M.; Mickle, J. P.; Wilder, B. J.; Maenhaut, W.; De Reu, L.
1984-04-01
Preliminary studies in our laboratories indicated alterations of specific trace metals in humans and animals treated with valproic acid (VPA), an anticonvulsant, and in animals treated with 4-pentenoic acid (4-PA), a fatty acid which produces a Reyes Syndrome-like condition. In this study, we report the results of PIXE analysis of plasma, liver, and brain of rats treated with VPA and 4-PA. Tissue specific changes in selenium, zinc and calcium may underly the pathophysiological changes produced by these chemicals.
Fast simulation of Proton Induced X-Ray Emission Tomography using CUDA
NASA Astrophysics Data System (ADS)
Beasley, D. G.; Marques, A. C.; Alves, L. C.; da Silva, R. C.
2013-07-01
A new 3D Proton Induced X-Ray Emission Tomography (PIXE-T) and Scanning Transmission Ion Microscopy Tomography (STIM-T) simulation software has been developed in Java and uses NVIDIA™ Common Unified Device Architecture (CUDA) to calculate the X-ray attenuation for large detector areas. A challenge with PIXE-T is to get sufficient counts while retaining a small beam spot size. Therefore a high geometric efficiency is required. However, as the detector solid angle increases the calculations required for accurate reconstruction of the data increase substantially. To overcome this limitation, the CUDA parallel computing platform was used which enables general purpose programming of NVIDIA graphics processing units (GPUs) to perform computations traditionally handled by the central processing unit (CPU). For simulation performance evaluation, the results of a CPU- and a CUDA-based simulation of a phantom are presented. Furthermore, a comparison with the simulation code in the PIXE-Tomography reconstruction software DISRA (A. Sakellariou, D.N. Jamieson, G.J.F. Legge, 2001) is also shown. Compared to a CPU implementation, the CUDA based simulation is approximately 30× faster.
The international fine aerosol networks
NASA Astrophysics Data System (ADS)
Cahill, Thomas A.
1993-04-01
The adoption by the United States of a PIXE-based protocol for its fine aerosol network, after open competitions involving numerous laboratories and methods, has encouraged cooperation with other countries possessing similar capabilities and similar needs. These informal cooperative programs, involving about a dozen countries at the end of 1991, almost all use PIXE as a major component of the analytical protocols. The University of California, Davis, Air Quality Group assisted such programs through indefinite loans of a quality assurance sampler, the IMPROVE Channel A, and analyses at no cost of a small fraction of the samples taken in a side-by-side configuration. In December 1991, the World Meteorological Organization chose a protocol essentially identical to IMPROVE for the Global Atmospheric Watch (GAW) network and began deploying units, the IMPROVE Channel A, to sites around the world. Preferred analyses include fine (less than about 2.5 μm) mass, ions by ion chromatography and elements by PIXE + PESA (or, lacking that, XRF). This paper will describe progress in both programs, giving examples of the utility of the data and projecting the future expansion of the network to about 20 GAW sites by 1994.
NASCAP simulation of PIX 2 experiments
NASA Technical Reports Server (NTRS)
Roche, J. C.; Mandell, M. J.
1985-01-01
The latest version of the NASCAP/LEO digital computer code used to simulate the PIX 2 experiment is discussed. NASCAP is a finite-element code and previous versions were restricted to a single fixed mesh size. As a consequence the resolution was dictated by the largest physical dimension to be modeled. The latest version of NASCAP/LEO can subdivide selected regions. This permitted the modeling of the overall Delta launch vehicle in the primary computational grid at a coarse resolution, with subdivided regions at finer resolution being used to pick up the details of the experiment module configuration. Langmuir probe data from the flight were used to estimate the space plasma density and temperature and the Delta ground potential relative to the space plasma. This information is needed for input to NASCAP. Because of the uncertainty or variability in the values of these parameters, it was necessary to explore a range around the nominal value in order to determine the variation in current collection. The flight data from PIX 2 were also compared with the results of the NASCAP simulation.
NASA Astrophysics Data System (ADS)
Manousakas, M.; Diapouli, E.; Papaefthymiou, H.; Migliori, A.; Karydas, A. G.; Padilla-Alvarez, R.; Bogovac, M.; Kaiser, R. B.; Jaksic, M.; Bogdanovic-Radovic, I.; Eleftheriadis, K.
2015-04-01
Particulate matter (PM) is an important constituent of atmospheric pollution especially in areas under the influence of industrial emissions. Megalopolis is a small city of 10,000 inhabitants located in central Peloponnese in close proximity to three coal opencast mines and two lignite fired power plants. 50 PM10 samples were collected in Megalopolis during the years 2009-11 for elemental and multivariate analysis. For the elemental analysis PIXE was used as one of the most effective techniques in APM analytical characterization. Altogether, the concentrations of 22 elements (Z = 11-33), whereas Black Carbon was also determined for each sample using a reflectometer. Factorization software was used (EPA PMF 3.0) for source apportionment analysis. The analysis revealed that major emission sources were soil dust 33% (7.94 ± 0.27 μg/m3), biomass burning 19% (4.43 ± 0.27 μg/m3), road dust 15% (3.63 ± 0.37 μg/m3), power plant emissions 13% (3.01 ± 0.44 μg/m3), traffic 12% (2.82 ± 0.37 μg/m3), and sea spray 8% (1.99 ± 0.41 μg/m3). Wind trajectories have suggested that metals associated with emission from the power plants came mainly from west and were connected with the locations of the lignite mines located in this area. Soil resuspension, road dust and power plant emissions increased during the warm season of the year, while traffic/secondary, sea spray and biomass burning become dominant during the cold season.
Elemental Analysis of Beryllium Samples Using a Microzond-EGP-10 Unit
NASA Astrophysics Data System (ADS)
Buzoverya, M. E.; Karpov, I. A.; Gorodnov, A. A.; Shishpor, I. V.; Kireycheva, V. I.
2017-12-01
Results concerning the structural and elemental analysis of beryllium samples obtained via different technologies using a Microzond-EGP-10 unit with the help of the PIXE and RBS methods are presented. As a result, the overall chemical composition and the nature of inclusions were determined. The mapping method made it possible to reveal the structural features of beryllium samples: to select the grains of the main substance having different size and chemical composition, to visualize the interfaces between the regions of different composition, and to describe the features of the distribution of impurities in the samples.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lemasson, Quentin; Kotula, Paul; Pichon, Laurent
2015-09-01
In the field of archaeometry, it is not uncommon to be presented with art objects that contain inscriptions, signatures and other writings that are nearly impossible to read. Scanned microbeam PIXE offers an attractive approach to attack this problem, but even then the distribution of characteristic X-rays of the element(s) used in these writings can remain illegible. We show in this paper that two methods were used to reveal the inscription: first the use of a GUPIXWin, TRAUPIXE and AGLAEMap software suite enables to make quantitative analysis of each pixel, to visualize the results and to select X-ray peaks thatmore » could enable to distinguish letters. Then, the Automated eXpert Spectral Image Analysis (AXSIA) program developed at Sandia, which analyzes the x-ray intensity vs. Energy and (X, Y) position “datacubes”, was used to factor the datacube into 1) principle component spectral shapes and 2) the weighting images of these components. The specimen selected for this study was a silver plaque representing a scroll from the so-called “MerkelscheTafelaufsatz,” a centrepiece made by the Nuremberg goldsmith Wenzel Jamnitzer in 1549. X-ray radiography of the plaque shows lines of different silver thicknesses, meaning that a text has been removed. The PIXE analysis used a 3-MeV proton beam focused to 50μm and scanned across the sample on different areas of interest of several cm². This analysis showed major elements of Cu and Ag, and minor elements such as Pb, Au, Hg. X-ray intensity maps were then made by setting windows on the various x-ray peaks but the writing on the centrepiece was not revealed even if the map of Cu after data treatment at AGLAE enabled to distinguish some letters. The AXSIA program enabled to factor two main spectral shapes from the datacube that were quite similar and involved virtually all of the X-rays being generated. Nevertheless, small differences between these factors were observed for the Cu K X-rays, Pb, Bi and Au L X-rays. The plot of the factor with the highest Au signal gave also information on the shape of some letters. The comparison of the results obtained by the two methods shows that they both drastically improve the resolution and contrast of such writings and that each of the method can also bring different information on the composition and thus the techniques used for the writing.« less
Energy dependent features of X-ray signals in a GridPix detector
NASA Astrophysics Data System (ADS)
Krieger, C.; Kaminski, J.; Vafeiadis, T.; Desch, K.
2018-06-01
We report on the calibration of an argon/isobutane (97.7%/2.3%)-filled GridPix detector with soft X-rays (277 eV to 8 keV) using the variable energy X-ray source of the CAST Detector Lab at CERN. We study the linearity and energy resolution of the detector using both the number of pixels hit and the total measured charge as energy measures. For the latter, the energy resolution σE / E is better than 10% (20%) for energies above 2 keV (0.5 keV). Several characteristics of the recorded events are studied.
PIXE in experimental archaeometry
NASA Astrophysics Data System (ADS)
Demortier, Guy; Van Oystaeyen, Bruno; Boullar, Annick
1984-04-01
A new step in the understanding of the degree of expertise in soldering in antiquity is discussed. It takes into account results from analyses of noncommercial alloys manufactured with techniques known in early times. The procedure involves only rudimentary means: mixture in a charcoal furnace of gold (or natural gold alloys such as electrum) with a natural cadmium mineral whose colour is close to that of gold and to that of gold solders described in the oldest metallurgical handbooks. PIXE both in nonvacuum and in microprobe arrangements is used to analyse ancient artifacts and soldering alloys of commercial origin and those manufactured by this "ancient procedure."
A GridPix-based X-ray detector for the CAST experiment
NASA Astrophysics Data System (ADS)
Krieger, C.; Kaminski, J.; Lupberger, M.; Desch, K.
2017-09-01
The CAST experiment has been searching for axions and axion-like particles for more than 10 years. The continuous improvements in the detector designs have increased the physics reach of the experiment far beyond what was originally conceived. As part of this development, a new detector based on a GridPix readout had been developed in 2014 and was mounted on the CAST experiment during the end of the data taking period of 2014 and the complete period in 2015. We report on the detector design, its advantages and the performance during both periods.
NASA Astrophysics Data System (ADS)
Smith, Jeremy; Ali, Salina; Nadareski, Benjamin; Safiq, Alexandrea; Yoskowitz, Joshua; Labrake, Scott; Vineyard, Michael
2013-10-01
We examined atmospheric aerosol samples collected in Schenectady NY for evidence of pollution. We collected aerosol samples using a nine stage cascade impactor which distributes the particulate matter by aerodynamic size onto 7.5 μm Kapton foils. We then used a 1MV electrostatic Pelletron accelerator to produce a 2.2 MeV proton beam to hit the impacted foils. X-ray intensity versus energy spectra were collected using an Amptek x-ray detector where the x-rays are produced from the proton beam interacting with the sample. This is called PIXE. The elemental composition and concentrations of the elements present in the aerosol samples were determined using a software package called GUPIX. We have found elements ranging from Al to Pb and in particular have found significant amounts of Pb and Br on some of our impacted foils, with a Br/Pb ratio of 0.6 +/- 0.2 which agrees with previous studies. This result suggests the presence of leaded aviation fuel perhaps due to the proximity of the collection site to a small airport with a significant amount of general aviation traffic. Union College.
PIXE Analysis of Metal Hull Bolts From HMB DeBraak
NASA Astrophysics Data System (ADS)
Correll, Francis D.; Cole, Lord K.; Slater, Charles J.; Vanhoy, Jeffrey R.; Fithian, Charles H.
2009-03-01
HMB DeBraak was a 16-gun British brig-sloop that sank in a squall on May 25, 1798 off Cape Henlopen, Delaware. Silt covered the wooden hull shortly after it sank, preserving it until DeBraak was raised in 1986. The items recovered from the ship include metal bolts that held the hull together. We used PIXE to measure the compositions of 45 of the bolts and found that they are nearly pure copper (98.3% on average), with most also containing small amounts of iron (0.87%), nickel (0.039%), arsenic (0.43%), silver (0.089%), lead (0.18%), and bismuth (0.12%). A few contain a little indium, tin, or antimony, but none contain zinc above the quantization level. The compositions are similar to those reported for 18th-century English copper, but different from several copper alloys also used to make hull bolts. We conclude that, when DeBraak was last fitted out in 1795-1797, the Royal Navy was still using bolts similar to William Forbes's mechanically hardened pure copper bolts. Forbes's process represents the successful innovation and application of new technology in Royal Navy ships during the wars of the late 18th century.
Measurement of trace elements in tree rings using the PIXE method
NASA Astrophysics Data System (ADS)
Aoki, Toru; Katayama, Yukio; Kagawa, Akira; Koh, Susumu; Yoshida, Kohji
1998-03-01
Standard materials were prepared in order to calculate element concentrations in tree samples using the particle induced X-ray emission (PIXE) method. Five standard solutions (1) Ti, Fe, Cu, As, Rb, Sr; (2) Ca, V, Co, Zn, As, Rb; (3) Ti, Mn, Ni, As, Sr; (4) K, Mn, Co, As, Rb, Sr; and (5) Ca, Mn, Cu, As, Rb, Sr, were added to filter papers. The dried filter papers were used as standard samples. Pellets of Pepperbush leaves (National Institute for Environmental Studies (NIES)) and Peach leaves (National Institute of Standards and Technology (NIST)) were used as references. The peak counts of Ca, Mn, Cu, Zn, Rb, and Sr in samples taken from a kaki ( Diospros kaki Thunb.) were measured and the concentrations (ppm) of the elements were calculated using the yield curve obtained from the standard filter papers. The concentrations of Mn, Zn, Rb, and Ca were compared with the data obtained from a separate INAA analysis. Concentrations of Mn, Zn, and Ca obtained by both methods were almost the same, but the concentrations of Rb differed slightly. The amounts of trace elements in samples taken from a sugi ( Cryptomeria japonica D. Don) were also measured.
Characterisation of traffic-generated particulate matter in Copenhagen
NASA Astrophysics Data System (ADS)
Wåhlin, Peter; Berkowicz, Ruwim; Palmgren, Finn
Fine and coarse fraction PM was simultaneously sampled with Dichotomous Stacked Filter Units at a road site and at an urban background site during both summer and winter periods. The collected mass was determined gravimetrically, and the contents of 26 elements were measured by Proton-Induced X-ray Emission (PIXE). NO x was monitored continuously at both sites. The road increments (road concentrations minus urban background concentrations) of PIXE elements, PM and NO x were analysed using the Constrained Physical Receptor Model (COPREM). Good agreement between the measured data and the model was achieved in both size fractions using four well-separated source profiles representing the emissions from exhaust, road/tyres, brakes and road salt. The analysis showed that the particles created by brake abrasion have aerodynamic diameters in the inhalable size range around 2.8 μm. This particle diameter is common mass median for a long list of heavy metals that are apportioned to the brakes source: Cr, Fe, Cu, Zn, Zr, Mo, Sn, Sb, Ba and Pb. Other significant contributions of Al, Si, K, Ca, Ti, Mn, Fe, Zn and Sr, mostly in the coarse particle fraction, are apportioned to the road/tyres source.
Trace elemental analysis in cancer-afflicted tissues of penis and testis by PIXE technique
NASA Astrophysics Data System (ADS)
Naga Raju, G. J.; John Charles, M.; Bhuloka Reddy, S.; Sarita, P.; Seetharami Reddy, B.; Rama Lakshmi, P. V. B.; Vijayan, V.
2005-04-01
PIXE technique was employed to estimate the trace elemental concentrations in the biological samples of cancerous penis and testis. A 3 MeV proton beam was employed to excite the samples. From the present results it can be seen that the concentrations of Cl, Fe and Co are lower in the cancerous tissue of the penis when compared with those in normal tissue while the concentrations of Cu, Zn and As are relatively higher. The concentrations of K, Ca, Ti, Cr, Mn, Br, Sr and Pb are in agreement within standard deviations in both cancerous and normal tissues. In the cancerous tissue of testis, the concentrations of K, Cr and Cu are higher while the concentrations of Fe, Co and Zn are lower when compared to those in normal tissue of testis. The concentrations of Cl, Ca, Ti and Mn are in agreement in both cancerous and normal tissues of testis. The higher levels of Cu lead to the development of tumor. Our results also support the underlying hypothesis of an anticopper, antiangiogenic approach to cancer therapy. The Cu/Zn ratios of both penis and testis were higher in cancer tissues compared to that of normal.
Trace elemental analysis of bituminuos coals using the Heidelberg proton microprobe
Chen, J.R.; Kneis, H.; Martin, B.; Nobiling, R.; Traxel, K.; Chao, E.C.T.; Minkin, J.A.
1981-01-01
Trace elements in coal can occur as components of either the organic constituents (macerals) or the inorganic constituents (minerals). Studies of the concentrations and distribution of the trace elements are vital to understanding the geochemical millieu in which the coal was formed and in evaluating the attempts to recover rare but technologically valuable metals. In addition, information on the trace element concentrations is important in predicting the environmental impact of burning particular coals, as many countries move toward greater utilization of coal reserves for energy production. Traditionally, the optical and the electron microscopes and more recently the electron microprobe have been used in studying the components of coal. The proton-induced X-ray emission (PIXE) microprobe offers a new complementary approach with an order of magnitude or more better minimum detection limit. We present the first measurements with a PIXE microprobe of the trace element concentrations of bituminous coal samples. Elemental analyses of the coal macerals-vitrinite, exinite, and inertinite-are discussed for three coal samples from the Eastern U.S.A., three samples from the Western U.S.A., and one sample from the Peoples Republic of China. ?? 1981.
NASA Astrophysics Data System (ADS)
Michelet-Habchi, C.; Barberet, Ph.; Dutta, R. K.; Guiet-Bara, A.; Bara, M.; Moretto, Ph.
2003-09-01
Regulation of vascular tone in the fetal extracorporeal circulation most likely depends on circulating hormones, local paracrine mechanisms and changes in membrane potential of vascular smooth muscle cells (VSMCs) and of vascular endothelial cells (VECs). The membrane potential is a function of the physiological activities of ionic channels (particularly, K + and Ca 2+ channels in these cells). These channels regulate the ionic distribution into these cells. Micro-particle induced X-ray emission (PIXE) analysis was applied to determine the ionic composition of VSMC and of VEC in the placental human allantochorial vessels in a physiological survival medium (Hanks' solution) modified by the addition of acetylcholine (ACh: which opens the calcium-sensitive K + channels, K Ca) and of high concentration of K + (which blocks the voltage-sensitive K + channels, K df). In VSMC (media layer), the addition of ACh induced no modification of the Na, K, Cl, P, S, Mg and Ca concentrations and high K + medium increased significantly the Cl and K concentrations, the other ion concentrations remaining constant. In endothelium (VEC), ACh addition implicated a significant increase of Na and K concentration, and high K + medium, a significant increase in Cl and K concentration. These results indicated the importance of K df, K Ca and K ATP channels in the regulation of K + intracellular distribution in VSMC and VEC and the possible intervention of a Na-K-2Cl cotransport and corroborated the previous electrophysiological data.
Two VLT 8.2-m Unit Telescopes in Action
NASA Astrophysics Data System (ADS)
1999-04-01
Visitors at ANTU - Astronomical Images from KUEYEN The VLT Control Room at the Paranal Observatory is becoming a busy place indeed. From here, two specialist teams of ESO astronomers and engineers now operate two VLT 8.2-m Unit Telescopes in parallel, ANTU and KUEYEN (formerly UT1 and UT2, for more information about the naming and the pronunciation, see ESO Press Release 06/99 ). Regular science observations have just started with the first of these giant telescopes, while impressive astronomical images are being obtained with the second. The work is hard, but the mood in the control room is good. Insiders claim that there have even been occasions on which the groups have had a friendly "competition" about which telescope makes the "best" images! The ANTU-team has worked with the FORS multi-mode instrument , their colleagues at KUEYEN use the VLT Test Camera for the ongoing tests of this new telescope. While the first is a highly developed astronomical instrument with a large-field CCD imager (6.8 x 6.8 arcmin 2 in the normal mode; 3.4 x 3.4 arcmin 2 in the high-resolution mode), the other is a less complex CCD camera with a smaller field (1.5 x 1.5 arcmin 2 ), suited to verify the optical performance of the telescope. As these images demonstrate, the performance of the second VLT Unit Telescope is steadily improving and it may not be too long before its optical quality will approach that of the first. First KUEYEN photos of stars and galaxies We present here some of the first astronomical images, taken with the second telescope, KUEYEN, in late March and early April 1999. They reflect the current status of the optical, electronic and mechanical systems, still in the process of being tuned. As expected, the experience gained from ANTU last year has turned out to be invaluable and has allowed good progress during this extremely delicate process. ESO PR Photo 19a/99 ESO PR Photo 19a/99 [Preview - JPEG: 400 x 433 pix - 160k] [Normal - JPEG: 800 x 866 pix - 457k] [High-Res - JPEG: 1985 x 2148 pix - 2.0M] ESO PR Photo 19b/99 ESO PR Photo 19b/99 [Preview - JPEG: 400 x 478 pix - 165k] [Normal - JPEG: 800 x 956 pix - 594k] [High-Res - JPEG: 3000 x 3583 pix - 7.1M] Caption to PR Photo 19a/99 : This photo was obtained with VLT KUEYEN on April 4, 1999. It is reproduced from an excellent 60-second R(ed)-band exposure of the innermost region of a globular cluster, Messier 68 (NGC 4590) , in the southern constellation Hydra (The Water-Snake). The distance to this 8-mag cluster is about 35,000 light years, and the diameter is about 140 light-years. The excellent image quality is 0.38 arcsec , demonstrating a good optical and mechanical state of the telescope, already at this early stage of the commissioning phase. The field measures about 90 x 90 arcsec 2. The original scale is 0.0455 pix/arcsec and there are 2048x2048 pixels in one frame. North is up and East is left. Caption to PR Photo 19b/99 : This photo shows the central region of spiral galaxy ESO 269-57 , located in the southern constellation Centaurus at a distance of about 150 million light-years. Many galaxies are seen in this direction at about the same distance, forming a loose cluster; there are also some fainter, more distant ones in the background. The designation refers to the ESO/Uppsala Survey of the Southern Sky in the 1970's during which over 15,000 southern galaxies were catalogued. ESO 269-57 is a tightly bound object of type Sar , the "r" referring to the "ring" that surrounds the bright centre, that is overexposed here. The photo is a composite, based on three exposures (Blue - 600 sec; Yellow-Green - 300 sec; Red - 300 sec) obtained with KUEYEN on March 28, 1999. The image quality is 0.7 arcsec and the field is 90 x 90 arcsec 2. North is up and East is left. ESO PR Photo 19c/99 ESO PR Photo 19c/99 [Preview - JPEG: 400 x 478 pix - 132k] [Normal - JPEG: 800 x 956 pix - 446k] [High-Res - JPEG: 3000 x 3583 pix - 4.6M] ESO PR Photo 19d/99 ESO PR Photo 19d/99 [Preview - JPEG: 400 x 454 pix - 86k] [Normal - JPEG: 800 x 907 pix - 301k] [High-Res - JPEG: 978 x 1109 pix - 282k] Caption to PR Photo 19c/99 : Somewhat further out in space, and right on the border between the southern constellations Hydra and Centaurus lies this knotty spiral galaxy, IC 4248 ; the distance is about 210 million light-years. It was imaged with KUEYEN on March 28, 1999, with the same filters and exposure times as used for Photo 19b/99. The image quality is 0.75 arcsec and the field is 90 x 90 arcsec 2. North is up and East is left. Caption to PR Photo 19d/99 : This is a close-up view of the double galaxy NGC 5090 (right) and NGC 5091 (left), in the southern constellation Centaurus. The first is a typical S0 galaxy with a bright diffuse centre, surrounded by a fainter envelope of stars (not resolved in this picture). However, some of the starlike objects seen in this region may be globular clusters (or dwarf galaxies) in orbit around NGC 5090. The other galaxy is of type Sa (the spiral structure is more developed) and is seen at a steep angle. The three-colour composite is based on frames obtained with KUEYEN on March 29, 1999, with the same filters and exposure times as used for Photo 19b/99. The image quality is 0.7 arcsec and the field is 90 x 90 arcsec 2. North is up and East is left. ( Note inserted on April 26: The original caption text identified the second galaxy as NGC 5090B - this error has now been corrected. ESO PR Photo 19e/99 ESO PR Photo 19e/99 [Preview - JPEG: 400 x 441 pix - 282k] [Normal - JPEG: 800 x 882 pix - 966k] [High-Res - JPEG: 3000 x 3307 pix - 6,4M] Caption to PR Photo 19e/99 : Wide-angle photo of the second 8.2-m VLT Unit Telescope, KUEYEN , obtained on March 10, 1999, with the main mirror and its cell in place at the bottom of the telescope structure. The Test Camera with which the astronomical images above were made, is positioned at the Cassegrain focus, inside this mirror cell. The Paranal Inauguration on March 5, 1999, took place under this telescope that was tilted towards the horizon to accommodate nearly 300 persons on the observing floor. Astronomical observations with ANTU have started On April 1, 1999, the first 8.2-m VLT Unit Telescope, ANTU , was "handed over" to the astronomers. Last year, about 270 observing proposals competed about the first, precious observing time at Europe's largest optical telescope and more than 100 of these were accommodated within the six-month period until the end of September 1999. The complete observing schedule is available on the web. These observations will be carried out in two different modes. During the Visitor Mode , the astronomers will be present at the telescope, while in the Service Mode , ESO observers perform the observations. The latter procedure allows a greater degree of flexibility and the possibility to assign periods of particularly good observing conditions to programmes whose success is critically dependent on this. The first ten nights at ANTU were allocated to service mode observations. After some initial technical problems with the instruments, these have now started. Already in the first night, programmes at ISAAC requiring 0.4 arcsec conditions could be satisfied, and some images better than 0.3 arcsec were obtained in the near-infrared . The first astronomers to use the telescope in visitors mode will be Professors Immo Appenzeller (Heidelberg, Germany; "Photo-polarimetry of pulsars") and George Miley (Leiden, The Netherlands; "Distant radio galaxies") with their respective team colleagues. How to obtain ESO Press Information ESO Press Information is made available on the World-Wide Web (URL: http://www.eso.org../ ). ESO Press Photos may be reproduced, if credit is given to the European Southern Observatory. Note also the dedicated webarea with VLT Information.
The Use of Ion Implantation for Materials Processing.
1983-09-28
SPUTTERING ANALYSIS WITH PIXE.......................... 31 J.M. Lambert, P.A. Treado, D . Trbojevic ,2 R.G. Alias, A.R. Knudson, G.W. Reynolds and F.R...Lambert and P. . Treado I D . Trbojevic R. G. Allas and A. R. Knudson 3 G. W. Reynolds and F. R. Vozzo 4 IGeorgetown University Washington, D . C. and...D.C. 20057 and 20375 D . Trbojevic Georgetown University, Washington, D.C. 20057 R.G. Alias and A.R. Knudson Naval Research Laboratory, Washington, D.C
New type of capillary for use as ion beam collimator and air-vacuum interface
NASA Astrophysics Data System (ADS)
Stoytschew, V.; Schulte-Borchers, M.; Božičević Mihalića, Iva; Perez, R. D.
2016-08-01
Glass capillaries offer a unique way to combine small diameter ion beam collimation with an air-vacuum interface for ambient pressure ion beam applications. Usually they have an opening diameter of a few microns, limiting the air inflow sufficiently to maintain stable conditions on the vacuum side. As the glass capillaries generally are quite thin and fragile, handling of the capillary in the experiment becomes difficult. They also introduce an X-ray background produced by the capillary wall material, which has to be shielded or subtracted from the data for Particle Induced X-ray Emission (PIXE) applications. To overcome both drawbacks, a new type of conical glass capillary has been developed. It has a higher wall thickness eliminating the low energy X-ray background produced by common capillaries and leading to a more robust lens. The results obtained in first tests show, that this new capillary is suitable for ion beam collimation and encourage further work on the capillary production process to provide thick wall capillaries with an outlet diameter in the single digit micro- or even nanometre range.
Petri, Setembrino; Becker-Kerber, Bruno; Romero, Guilherme Raffaeli; Rizzutto, Marcia de Almeida; Rodrigues, Fabio; Galante, Douglas; da Silva, Tiago Fiorini; Curado, Jessica F.; Rangel, Elidiane Cipriano; Ribeiro, Rafael Parra; Pacheco, Mírian Liza Alves Forancelli
2016-01-01
Exceptionally well-preserved three-dimensional insects with fine details and even labile tissues are ubiquitous in the Crato Member Konservat Lagerstätte (northeastern Brazil). Here we investigate the preservational pathways which yielded such specimens. We employed high resolution techniques (EDXRF, SR-SXS, SEM, EDS, micro Raman, and PIXE) to understand their fossilisation on mineralogical and geochemical grounds. Pseudomorphs of framboidal pyrite, the dominant fossil microfabric, display size variation when comparing cuticle with inner areas or soft tissues, which we interpret as the result of the balance between ion diffusion rates and nucleation rates of pyrite through the originally decaying carcasses. Furthermore, the mineral fabrics are associated with structures that can be the remains of extracellular polymeric substances (EPS). Geochemical data also point to a concentration of Fe, Zn, and Cu in the fossils in comparison to the embedding rock. Therefore, we consider that biofilms of sulphate reducing bacteria (SRB) had a central role in insect decay and mineralisation. Therefore, we shed light on exceptional preservation of fossils by pyritisation in a Cretaceous limestone lacustrine palaeoenvironment. PMID:28028459
Molecular imaging of cannabis leaf tissue with MeV-SIMS method
NASA Astrophysics Data System (ADS)
Jenčič, Boštjan; Jeromel, Luka; Ogrinc Potočnik, Nina; Vogel-Mikuš, Katarina; Kovačec, Eva; Regvar, Marjana; Siketić, Zdravko; Vavpetič, Primož; Rupnik, Zdravko; Bučar, Klemen; Kelemen, Mitja; Kovač, Janez; Pelicon, Primož
2016-03-01
To broaden our analytical capabilities with molecular imaging in addition to the existing elemental imaging with micro-PIXE, a linear Time-Of-Flight mass spectrometer for MeV Secondary Ion Mass Spectrometry (MeV-SIMS) was constructed and added to the existing nuclear microprobe at the Jožef Stefan Institute. We measured absolute molecular yields and damage cross-section of reference materials, without significant alteration of the fragile biological samples during the duration of measurements in the mapping mode. We explored the analytical capability of the MeV-SIMS technique for chemical mapping of the plant tissue of medicinal cannabis leaves. A series of hand-cut plant tissue slices were prepared by standard shock-freezing and freeze-drying protocol and deposited on the Si wafer. We show the measured MeV-SIMS spectra showing a series of peaks in the mass area of cannabinoids, as well as their corresponding maps. The indicated molecular distributions at masses of 345.5 u and 359.4 u may be attributed to the protonated THCA and THCA-C4 acids, and show enhancement in the areas with opened trichome morphology.
Detection and Dynamic Analysis of Space Debris in the Geo Ring
NASA Astrophysics Data System (ADS)
Lacruz, E.; Abad, C.; Downes, J. J.; Casanova, D.; Tresaco, E.
2018-01-01
There are different populations of space debris (SD) in the geostationary (GEO) region. It is of great interest to know their dynamics, in order to contribute to aspects such as alerts against possible collisions, repositioning of GEO satellites or placing those satellites that come into service. In this contribution we present a study about the detection and dynamic analysis of SD located in the GEO ring. Using the telescopes of the Venezuelan Obseratory National (VON), a large amount of astrometric observations have been acquired. A preliminary dynamic analysis of them has been carried out, which evidences the average relative motion of these orbiters with a mean absolute error for coordinates of ≍ 0.09 pix.
Elemental and structural studies at the bone-cartilage interface
NASA Astrophysics Data System (ADS)
Bradley, D. A.; Kaabar, W.; Gundogdu, O.
2012-02-01
The techniques μProton-Induced X-and γ-ray Emission, μ-PIXE and μ-PIGE, were used to investigate trace and essential element distributions in sections of normal and osteoarthritic (OA) human femoral head. μ-PIGE yielded 2-D mappings of Na and F while Ca, Z, P and S were mapped by μ-PIXE. The concentration of chondroitin sulphate supporting functionality in healthy cartilage is significantly reduced in OA samples. Localised Zn points to osteoblastic/osteoclastic activity at the bone-cartilage interface. Small-angle X-ray scattering applied to decalcified OA-affected tissue showed spatial alterations of collagen fibres of decreased axial periodicity compared to normal collagen type I.
VizieR Online Data Catalog: Variables in Centaurus field F170 (Pietrukowicz+, 2012)
NASA Astrophysics Data System (ADS)
Pietrukowicz, P.; Minniti, D.; Alonso-Garcia; J.; Hempel, M.
2011-10-01
VJHKs photometry of stars in two VIMOS disc fields: F167 and F170. Data table with 333 variables detected in the field F170 in Centaurus. The optical observations were taken with the 8.2-m Unit Telescope 3 + VIMOS imager with a scale of 0.205"/pix at ESO Very Large Telescope at Paranal Observatory. Date of the observations: Apr 11-12, 2005. The infrared observations were obtained with the 4.1-m VISTA telescope + VIRCAM with a scale of 0.34"/pix also at Paranal Observatory. Date of the observations: Mar-Apr 2010. (4 data files).
NASA Astrophysics Data System (ADS)
Bejjani, A.; Roumié, M.; Akkad, S.; El-Yazbi, F.; Nsouli, B.
2016-03-01
We have demonstrated, in previous studies that Particle Induced X-ray Emission (PIXE) is one of the most rapid and accurate choices for quantification of an active ingredient, in a solid drug, from the reactions induced on its specific heteroatom using pellets made from original tablets. In this work, PIXE is used, for the first time, for simultaneous quantification of two active ingredients, amoxicillin trihydrate and potassium clavulanate, in six different commercial antibiotic type of drugs. Since the quality control process of a drug covers a large number of samples, the scope of this study was also to found the most rapid and low cost sample preparation needed to analyze these drugs with a good precision. The chosen drugs were analyzed in their tablets' "as received" form, in pellets made from the powder of the tablets and also in pellets made from the powder of the tablets after being heated up to 70 °C to avoid any molecular destruction until constant weight and removal of humidity. The quantification validity related to the aspects of each sample preparation (homogeneity of the drug components and humidity) are presented and discussed.
Next generation phage display by use of pVII and pIX as display scaffolds.
Løset, Geir Åge; Sandlie, Inger
2012-09-01
Phage display technology has evolved to become an extremely versatile and powerful platform for protein engineering. The robustness of the phage particle, its ease of handling and its ability to tolerate a range of different capsid fusions are key features that explain the dominance of phage display in combinatorial engineering. Implementation of new technology is likely to ensure the continuation of its success, but has also revealed important short comings inherent to current phage display systems. This is in particular related to the biology of the two most popular display capsids, namely pIII and pVIII. Recent findings using two alternative capsids, pVII and pIX, located to the phage tip opposite that of pIII, suggest how they may be exploited to alleviate or circumvent many of these short comings. This review addresses important aspects of the current phage display standard and then discusses the use of pVII and pIX. These may both complement current systems and be used as alternative scaffolds for display and selection to further improve phage display as the ultimate combinatorial engineering platform. Copyright © 2012 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Isaure, M. P.; Laboudigue, A.; Manceau, A.; Sarret, G.; Tiffreau, C.; Trocellier, P.
2001-07-01
Depositing dredged sediments on soils is usual but it is a hazardous practice for the local environment when these sediments are polluted by heavy metals. This chemical hazard can be assessed by determining the speciation of metals. In this study, slags highly polluted with Zn and originated from a contaminated dredged sediment were investigated. Zn speciation was studied by laterally resolved techniques such as μ-particle induced X-ray emission (μ-PIXE), μ-Rutherford backscattering spectrometry (μ-RBS), μ-extended X-ray absorption fine structure (μ-EXAFS), and bulk analyses such as powder EXAFS spectroscopy. μ-PIXE and μ-RBS results showed that high concentrations of Zn were associated with S in localised areas at the surface of the slags while moderate amounts of Zn were mainly associated with Fe in the matrix. EXAFS results allowed to identify ZnS and Zn sorbed on ferrihydrite (5Fe 2O 3·9H 2O), proxy for iron oxy-hydroxides, as the main Zn-bearing phases. The occurrence of this Zn-iron oxy-hydroxide is interpreted as a mobilisation of Zn released from ZnS oxidation.
NASA Astrophysics Data System (ADS)
Pajouhafsar, Yasmin; Alis Manso Rodriguez Team; Sherry Yennello Team
2017-09-01
Particle Induced X-Ray Emission (PIXE) is a non-destructive analytical technique that is used for various tasks, such as elemental composition. The x-rays are emitted when electrons transition from higher to lower energy levels, causing vacancies in the atom's electron configuration. The overall goals of this research are to successfully set up a PIXE experiment and to obtain elemental concentrations for various samples, using the K150 proton beam in the Cyclotron Institute at Texas A&M University. The x-rays produced are unique to each element and analyzed with reference to their known energies. The setup consists of 3 different detectors, providing a wide range of energies: XR-100T CdTe γ/X-Ray, XR-100T/CR Si and XR-100SDD. Accelerating 3.6 MeV protons from the K150 and using PIXE, we determine concentrations from the NaCl samples provided by the Chemical Engineering Department. The concentrations for each element found in the NaCl thin films are obtained and analyzed through the software, GUPIXWIN. DOE Grant (DE-FG02-93ER40773) and Welch Foundation (A-1266).
In-air RBS measurements at the LAMFI external beam setup
DOE Office of Scientific and Technical Information (OSTI.GOV)
Silva, T. F.; Added, N.; Moro, M. V.
2014-11-11
This work describes new developments in the external beam setup of the Laboratory of Material Analysis with Ion Beams of the University of São Paulo (LAMFI-USP). This setup was designed to be a versatile analytical station to analyze a broad range of samples. In recent developments, we seek the external beam Rutherford Backscattering Spectroscopy (RBS) analysis to complement the Particle Induced X-ray Emission (PIXE) measurements. This work presents the initial results of the external beam RBS analysis as well as recent developments to improve the energy resolution RBS measurements, in particular tests to seek for sources of resolution degradation. Thesemore » aspects are discussed and preliminary results of in-air RBS analysis of some test samples are presented.« less
Time resolved aerosol monitoring in the urban centre of Soweto
NASA Astrophysics Data System (ADS)
Formenti, P.; Annegarn, H. J.; Piketh, S. J.
1998-03-01
A programme of aerosol sampling was conducted from 1982 to 1984 in the urban area of Soweto, Johannesburg, South Africa. The particulate matter (aerodynamic diameter <15 μm) was collected using a two hours time resolution single stage streaker sampler and elemental concentrations were resolved via Particle Induced X-ray Emission (PIXE) analysis. Samples have been selected for analysis from an aerosol sample archive to establish base-line atmospheric conditions that existed in Soweto prior to large scale electrification, and to establish source apportionment of crustal elements between coal smoke and traffic induced road dust, based on chemical elemental measurements. A novel technique is demonstrated for processing PIXE-derived time sequence elemental concentration vectors. Slowly varying background components have been extracted from sulphur and crustal aerosol components, using alternatively two digital filters: a moving minimum, and a moving average. The residuals of the crustal elements, assigned to locally generated aerosol components, were modelled using surrogate tracers: sulphur as a surrogate for coal smoke; and Pb as a surrogate for traffic activity. Results from this source apportionment revealed coal emissions contributed between 40% and 50% of the aerosol mineral matter, while 18-22% originated from road dust. Background aerosol, characteristic of the regional winter aerosol burden over the South African Highveld, was between 12% and 21%. Minor contributors identified included a manganese smelter, located 30 km from the sampling site, and informal trash burning, as the source of intermittent heavy metals (Cu, Zn). Elemental source profiles derived for these various sources are presented.
Ion Microbeam Analyses of Dust Particles and Codeposits from JET with the ITER-Like Wall.
Fazinić, Stjepko; Tadić, Tonči; Vukšić, Marin; Rubel, Marek; Petersson, Per; Fortuna-Zaleśna, Elżbieta; Widdowson, Anna
2018-05-01
Generation of metal dust in the JET tokamak with the ITER-like wall (ILW) is a topic of vital interest to next-step fusion devices because of safety issues with plasma operation. Simultaneous Nuclear Reaction Analysis (NRA) and Particle-Induced X-ray Emission (PIXE) with a focused four MeV 3 He microbeam was used to determine the composition of dust particles related to the JET operation with the ILW. The focus was on "Be-rich particles" collected from the deposition zone on the inner divertor tile. The particles found are composed of a mix of codeposited species up to 120 μm in size with a thickness of 30-40 μm. The main constituents are D from the fusion fuel, Be and W from the main plasma-facing components, and Ni and Cr from the Inconel grills of the antennas for auxiliary plasma heating. Elemental concentrations were estimated by iterative NRA-PIXE analysis. Two types of dust particles were found: (i) larger Be-rich particles with Be concentrations above 90 at% with a deuterium presence of up to 3.4 at% and containing Ni (1-3 at%), Cr (0.4-0.8 at%), W (0.2-0.9 at%), Fe (0.3-0.6 at%), and Cu and Ti in lower concentrations and (ii) small particles rich in Al and/or Si that were in some cases accompanied by other elements, such as Fe, Cu, or Ti or W and Mo.
Characterization of inertial confinement fusion (ICF) targets using PIXE, RBS, and STIM analysis.
Li, Yongqiang; Liu, Xue; Li, Xinyi; Liu, Yiyang; Zheng, Yi; Wang, Min; Shen, Hao
2013-08-01
Quality control of the inertial confinement fusion (ICF) target in the laser fusion program is vital to ensure that energy deposition from the lasers results in uniform compression and minimization of Rayleigh-Taylor instabilities. The technique of nuclear microscopy with ion beam analysis is a powerful method to provide characterization of ICF targets. Distribution of elements, depth profile, and density image of ICF targets can be identified by particle-induced X-ray emission, Rutherford backscattering spectrometry, and scanning transmission ion microscopy. We present examples of ICF target characterization by nuclear microscopy at Fudan University in order to demonstrate their potential impact in assessing target fabrication processes.
NASA Astrophysics Data System (ADS)
Isaure, Marie-Pierre; Laboudigue, Agnès; Manceau, Alain; Sarret, Géraldine; Tiffreau, Christophe; Trocellier, Patrick; Lamble, Géraldine; Hazemann, Jean-Louis; Chateigner, Daniel
2002-05-01
Dredging and disposal of sediments onto agricultural soils is a common practice in industrial and urban areas that can be hazardous to the environment when the sediments contain heavy metals. This chemical hazard can be assessed by evaluating the mobility and speciation of metals after sediment deposition. In this study, the speciation of Zn in the coarse (500 to 2000 μm) and fine (<2 μm) fractions of a contaminated sediment dredged from a ship canal in northern France and deposited on an agricultural soil was determined by physical analytical techniques on raw and chemically treated samples. Zn partitioning between coexisting mineral phases and its chemical associations were first determined by micro-particle-induced X-ray emission and micro-synchrotron-based X-ray radiation fluorescence. Zn-containing mineral species were then identified by X-ray diffraction and powder and polarized extended X-ray absorption fine structure spectroscopy (EXAFS). The number, nature, and proportion of Zn species were obtained by a coupled principal component analysis (PCA) and least squares fitting (LSF) procedure, applied herein for the first time to qualitatively (number and nature of species) and quantitatively (relative proportion of species) speciate a metal in a natural system. The coarse fraction consists of slag grains originating from nearby Zn smelters. In this fraction, Zn is primarily present as sphalerite (ZnS) and to a lesser extent as willemite (Zn 2SiO 4), Zn-containing ferric (oxyhydr)oxides, and zincite (ZnO). In the fine fraction, ZnS and Zn-containing Fe (oxyhydr)oxides are the major forms, and Zn-containing phyllosilicate is the minor species. Weathering of ZnS, Zn 2SiO 4, and ZnO under oxidizing conditions after the sediment disposal accounts for the uptake of Zn by Fe (oxyhydr)oxides and phyllosilicates. Two geochemical processes can explain the retention of Zn by secondary minerals: uptake on preexisting minerals and precipitation with dissolved Fe and Si. The second process likely occurs because dissolved Zn and Si are supersaturated with respect to Zn phyllosilicate. EXAFS spectroscopy, in combination with PCA and LSF, is shown to be a meaningful approach to quantitatively determining the speciation of trace elements in sediments and soils.
NASA Astrophysics Data System (ADS)
Roumie, M.; Chiari, M.; Srour, A.; Sa'adeh, H.; Reslan, A.; Sultan, M.; Ahmad, M.; Calzolai, G.; Nava, S.; Zubaidi, Th.; Rihawy, M. S.; Hussein, T.; Arafah, D.-E.; Karydas, A. G.; Simon, A.; Nsouli, B.
2016-03-01
The present work is a part of a scientific study conducted among several Arab countries in west Asia, under an International Atomic Energy Agency (IAEA) regional technical cooperation project for Arasia region. The project aims at producing for the first time a database of particulate matter (PM) elemental concentrations in the region that will help in future air quality studies in order to identify commonalities and differences in the presence and contribution of fingerprint pollution sources among the Arasia Member States. The first regional campaign was launched simultaneously in Lebanon, Iraq, Jordan, Syria and United Arab Emirates, using a harmonized sampling and analysis protocol of PM10 and PM2.5 samples. Different samples, collected between October 2014 and February 2015, from the participating countries, were analyzed by PIXE technique and gravimetric measurements were also carried out. The first results of the study will be discussed in a regional perspective. Our study shows that concentrations of fine aerosol fractions are often exceeding the WHO standard values as well as showing some disparities in the obtained values between the different sampling sites. However, some trend similarities of variations with time could also be observed, suggesting a common influence by trans-boundary or external sources of air pollution.
PIXE Analysis of Metal Hull Bolts From HMB DeBraak
DOE Office of Scientific and Technical Information (OSTI.GOV)
Correll, Francis D.; Cole, Lord K.; Slater, Charles J.
2009-03-10
HMB DeBraak was a 16-gun British brig-sloop that sank in a squall on May 25, 1798 off Cape Henlopen, Delaware. Silt covered the wooden hull shortly after it sank, preserving it until DeBraak was raised in 1986. The items recovered from the ship include metal bolts that held the hull together. We used PIXE to measure the compositions of 45 of the bolts and found that they are nearly pure copper (98.3% on average), with most also containing small amounts of iron (0.87%), nickel (0.039%), arsenic (0.43%), silver (0.089%), lead (0.18%), and bismuth (0.12%). A few contain a little indium,more » tin, or antimony, but none contain zinc above the quantization level. The compositions are similar to those reported for 18th-century English copper, but different from several copper alloys also used to make hull bolts. We conclude that, when DeBraak was last fitted out in 1795-1797, the Royal Navy was still using bolts similar to William Forbes's mechanically hardened pure copper bolts. Forbes's process represents the successful innovation and application of new technology in Royal Navy ships during the wars of the late 18th century.« less
In-pixel conversion with a 10 bit SAR ADC for next generation X-ray FELs
NASA Astrophysics Data System (ADS)
Lodola, L.; Batignani, G.; Benkechkache, M. A.; Bettarini, S.; Casarosa, G.; Comotti, D.; Dalla Betta, G. F.; Fabris, L.; Forti, F.; Grassi, M.; Latreche, S.; Malcovati, P.; Manghisoni, M.; Mendicino, R.; Morsani, F.; Paladino, A.; Pancheri, L.; Paoloni, E.; Ratti, L.; Re, V.; Rizzo, G.; Traversi, G.; Vacchi, C.; Verzellesi, G.; Xu, H.
2016-07-01
This work presents the design of an interleaved Successive Approximation Register (SAR) ADC, part of the readout channel for the PixFEL detector. The PixFEL project aims at substantially advancing the state-of-the-art in the field of 2D X-ray imaging for applications at the next generation Free Electron Laser (FEL) facilities. For this purpose, the collaboration is developing the fundamental microelectronic building blocks for the readout channel. This work focuses on the design of the ADC carried out in a 65 nm CMOS technology. To obtain a good tradeoff between power consumption, conversion speed and area occupation, an interleaved SAR ADC architecture was adopted.
VizieR Online Data Catalog: New companions to nearby low-mass stars (Jodar+, 2013)
NASA Astrophysics Data System (ADS)
Jodar, E.; Perez-Garrido, A.; Diaz-Sanchez, A.; Villo, I.; Rebolo, R.; Perez-Prieto, J. A.
2016-04-01
we present the results of a high-resolution imaging survey of 451 late K and M dwarfs selected from the Gliese catalogue (Gliese 1969; Gliese & Jahreiss 1979, 1991, Cat. V/70). The observations were carried out during 2008 using Astralux at the 2.2m telescope at the Centro Astronomico Hispano Aleman (CAHA, Almeria, Spain) and FastCam at the 1.5m Carlos Sanchez Telescope at Teide Observatory (OT, Tenerife, Spain). The observations were done in the Sloan Digital Sky Survey (SDSS) i band at CAHA with pixel scales of ~47mas/pix and the Johnson-Cousin I band at OT with ~43mas/pix. (3 data files).
NASA Astrophysics Data System (ADS)
Indriati Arifin, Yayu; Sakakibara, Masayuki; Sera, Koichiro
2017-06-01
We performed the Particle Induced X-ray Emission (PIXE) analysis on scalp hair samples of 115 ASGM miners and inhabitants of Gorontalo Utara regency. Along with mercury (Hg), we presented other trace elements such as Copper (Cu) and Manganese (Mn). Concentrations of Cu, Mn and Hg in the scalp hairs of ASGM miners are higher non miners. Significant and positive correlations coefficients between Cu and Hg concentration with Mn concentration may indicate that there are still unknown metabolism process related with ASGM activities.
Nsouli, Bilal; Bejjani, Alice; Negra, Serge Della; Gardon, Alain; Thomas, Jean-Paul
2010-09-01
In order to evaluate the potential of accelerator based analytical techniques ((particle induced X-ray emission (PIXE), particle induced gamma-ray emission (PIGE), and particle desorption mass spectrometry (PD-MS)) for the analysis of commercial pharmaceutical products in their solid dosage form, the fluphenazine drug has been taken as a representative example. It is demonstrated that PIXE and PIGE are by far the best choice for quantification of the active ingredient (AI) (certification with 7% precision) from the reactions induced on its specific heteroatoms fluorine and sulfur using pellets made from original tablets. Since heteroatoms cannot be present in all types of drugs, the PD-MS technique, which makes easily the distinction between AI(s) and excipients, has been evaluated for the same material. It is shown that the quantification of AI is obtained via the detection of its protonated molecule. However, calibration curves have to be made from the secondary ion yield variations since matrix effects of various nature are characteristics of such mixtures of heterogeneous materials (including deposits from soluble components). From the analysis of solid tablets, (either transformed into pellets and even as received), it is strongly suggested that the physical state of the grains in the mixture is a crucial parameter in the ion emission and accordingly for the calibration curves. As a result of our specific (but not optimized) conditions the resulting precision is <17% with an almost linear range extending from 0.04 to 7.87 mg of AI in a tablet made under the manufacturer conditions (the commercial drug product is labeled at 5 mg).
Depth profile by Total IBA in perovskite active layers for solar cells
NASA Astrophysics Data System (ADS)
Barreiros, M. A.; Alves, L. C.; Brites, M. J.; Corregidor, V.
2017-08-01
In recent years the record efficiency of perovskite solar cells (PSCs) has been updated exceeding now 20%. However, it is difficult to make PSCs consistently. Definite correlation has been established between the PSC performance and the perovskite film quality which involves mainly morphology, crystallinity and composition. The manufacturing development of these devices is dependent on the characterisation methodologies, on the availability of suitable and reliable analytical techniques to assess the materials composition and quality and on the relationship of these results with the cell performance. Ion beam analytical (IBA) techniques jointly with a micro-ion beam are powerful tools for materials characterisation and can provide a valuable input for the knowledge of perovskite films. Perovskite films based on CH3NH3PbI3 were prepared (from CH3NH3I and PbI2 precursors) in a planar architecture and in a mesoporous TiO2 scaffold. Proton and helium micro-beams at different energies were used in the analysis of PSC active layers, previously characterised by SEM-FEG (Scanning Electron Microscopy with a field emission gun) and XRD (X-ray diffraction). Self-consistent fit of all the obtained PIXE (Particle Induced X-ray Emission) and RBS (Rutherford Backscattering Spectrometry) spectra through Total IBA approach provided depth profiling of perovskite, its precursors and TiO2 and assess their distribution in the films. PbI2 presence and location on the active layer may hinder the charge transport and highly affect the cell performance. IBA techniques allowed to identify regions of non-uniform surface coverage and homogeneous areas and it was possible to establish the undesired presence of PbI2 and its quantitative depth profile in the planar architecture film. In the mesostructured perovskite film it was verified a non-homogeneous distribution with a decreasing of perovskite concentration down to the thin blocking layer. The good agreement between the best fits obtained in a Total IBA approach and the experimental data granted reliability to depth profile results for the studied perovskite films.
Study of atmospheric aerosols by IBA techniques: The LABEC experience
NASA Astrophysics Data System (ADS)
Lucarelli, F.; Calzolai, G.; Chiari, M.; Nava, S.; Carraresi, L.
2018-02-01
At the 3 MV Tandetron accelerator of the LABEC laboratory of INFN (Florence, Italy) an external beam facility is fully dedicated to PIXE-PIGE measurements of the elemental composition of atmospheric aerosols. All the elements with Z > 10 are simultaneously detected by PIXE typically in one minute. This setup allows us an easy automatic positioning, changing and scanning of samples collected by different kinds of devices: long series of daily PM (Particulate Matter) samples can be analysed in short times, as well as size-segregated and high time-resolution aerosol samples. Thanks to the capability of detecting all the crustal elements, PIXE-PIGE analyses are unrivalled in the study of mineral dust: consequently, they are very effective in the study of natural aerosols, like, for example, Saharan dust intrusions. Among the detectable elements there are also important markers of anthropogenic sources, which allow effective source apportionment studies in polluted urban environments using a multivariate method like Positive Matrix Factorization (PMF). Examples regarding recent monitoring campaigns, performed in urban and remote areas, both daily and with high time resolution (hourly samples), as well as with size selection, are presented. The importance of the combined use of the Particle Induced Gamma Ray emission technique (PIGE) and of other complementary (non-nuclear) techniques is highlighted.
Pre-Hispanic ceramics analyzed using PIXE and radiographic techniques
NASA Astrophysics Data System (ADS)
Lima, S. C.; Rizzutto, M. A.; Added, N.; Barbosa, M. D. L.; Trindade, G. F.; Fleming, M. I. D. A.
2011-12-01
Ceramics objects are the most common artifacts found during excavation of archaeological sites and often depicts cultural habits and manufacturing technologies of the culture. The determination of macroscopic and microscopic characteristics of the ceramic objects such as the ceramic porosity, addition of tempers in the clay, main chemical components and the trace elements present in the ceramic can reveal many aspects about the manufacturing processes used by the culture, its degree of development, the provenance of the raw materials and the exchange networks. Also the radiography can help to investigate the manufactured processes, the size of the tempers used and the conservation status of the artifacts. In this present work two non-destructive techniques, radiography and PIXE (Particle Induced X-ray Emission) were used to characterize one set of thirty-six pre-Hispanic ceramic pieces from the Chimu Culture conserved in the Museu de Arqueologia e Etnologia (MAE/USP). The PIXE analyses performed in the external beam setup at LAMFI (Laboratório de Análise de Materiais por Feixes Iônicos) allowed measure the principal chemical elements such as Al, Si, K, Ti, Fe and Ca, present in this group of pieces. X-ray imagings allowed identify the manufacture processes, the granularity of the tempers used, as well as the similarity and the differences between the pieces studied.
NASA Astrophysics Data System (ADS)
Schofield, Robert; Lefevre, Harlan; Shaffer, Michael
1989-04-01
Energy-loss scanning transmission ion microscopy (ELSTIM or just STIM), PIXE and electron microprobe techniques are used to investigate certain minor element accumulations in a few spiders and scorpions. STIM and PIXE are used to survey the unsectioned specimens, while electron microprobe techniques are used for higher resolution investigations of several sections of the specimens. Concentration values measured using STIM and PIXE are found to be in satisfactory agreement with those measured using electron probe microanalysis. A garden spider Araneus diadematus is found to contain high concentrations of zinc in a thin layer near the surface of its fangs (reaching 23% of dry weight), and manganese in its marginal teeth (about 5% of dry weight). A wolf spider Alopecosa kochi is found to have similar concentrations of zinc in a layer near the surface of it's fang, and concentrations of manganese reaching 1.5% in a layer beneath the zinc containing layer. A scorpion Centruroides sp. is found to contain high concentrations of iron (reaching 8%) and zinc (reaching 24%) in the tips of teeth on the cheliceral fingers, and manganese (about 5%) in the stinger. The hypothesis that these elements simply harden the cuticle does not appear to explain their segregation patterns.
PFM2: a 32 × 32 processor for X-ray diffraction imaging at FELs
NASA Astrophysics Data System (ADS)
Manghisoni, M.; Fabris, L.; Re, V.; Traversi, G.; Ratti, L.; Grassi, M.; Lodola, L.; Malcovati, P.; Vacchi, C.; Pancheri, L.; Benkechcache, M. E. A.; Dalla Betta, G.-F.; Xu, H.; Verzellesi, G.; Ronchin, S.; Boscardin, M.; Batignani, G.; Bettarini, S.; Casarosa, G.; Forti, F.; Giorgi, M.; Paladino, A.; Paoloni, E.; Rizzo, G.; Morsani, F.
2016-11-01
This work is concerned with the design of a readout chip for application to experiments at the next generation X-ray Free Electron Lasers (FEL). The ASIC, named PixFEL Matrix (PFM2), has been designed in a 65 nm CMOS technology and consists of 32 × 32 pixels. Each cell covers an area of 110 × 110 μm2 and includes a low-noise charge sensitive amplifier (CSA) with dynamic signal compression, a time-variant shaper used to process the preamplifier output signal, a 10-bit successive approximation register (SAR) analog-to-digital converter (ADC) and digital circuitry for channel control and data readout. Two different solutions for the readout channel, based on different versions of the time-variant filter, have been integrated in the chip. Both solutions can be operated in such a way to cope with the high frame rate (exceeding 1 MHz) foreseen for future X-ray FEL machines. The ASIC will be bump bonded to a slim/active edge pixel sensor to form the first demonstrator for the PixFEL X-ray imager. This work has been carried out in the frame of the PixFEL project funded by Istituto Nazionale di Fisica Nucleare (INFN), Italy.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jakubek, J.; Cejnarova, A.; Platkevic, M.
Single quantum counting pixel detectors of Medipix type are starting to be used in various radiographic applications. Compared to standard devices for digital imaging (such as CCDs or CMOS sensors) they present significant advantages: direct conversion of radiation to electric signal, energy sensitivity, noiseless image integration, unlimited dynamic range, absolute linearity. In this article we describe usage of the pixel device TimePix for image accumulation gated by late trigger signal. Demonstration of the technique is given on imaging coincidence instrumental neutron activation analysis (Imaging CINAA). This method allows one to determine concentration and distribution of certain preselected element in anmore » inspected sample.« less
Mulware, Stephen Juma
2015-01-01
The properties of many biological materials often depend on the spatial distribution and concentration of the trace elements present in a matrix. Scientists have over the years tried various techniques including classical physical and chemical analyzing techniques each with relative level of accuracy. However, with the development of spatially sensitive submicron beams, the nuclear microprobe techniques using focused proton beams for the elemental analysis of biological materials have yielded significant success. In this paper, the basic principles of the commonly used microprobe techniques of STIM, RBS, and PIXE for trace elemental analysis are discussed. The details for sample preparation, the detection, and data collection and analysis are discussed. Finally, an application of the techniques to analysis of corn roots for elemental distribution and concentration is presented.
Begley, Carolyn; Simpson, Trefford; Liu, Haixia; Salvo, Eliza; Wu, Ziwei; Bradley, Arthur; Situ, Ping
2013-04-12
The purpose of this study was to test the association between tear film fluorescence changes during tear break-up (TBU) or thinning and the concurrent ocular sensory response. Sixteen subjects kept one eye open as long as possible (MBI), indicated their discomfort level continuously, and rated ocular sensations of irritation, stinging, burning, pricking, and cooling using visual analog scales (VAS). Fluorescence of the tear film was quantified by a pixel-based analysis of the median pixel intensity (PI), TBU, and percentage of dark pixels (DarkPix) over time. A cutoff of 5% TBU was used to divide subjects into either break-up (BU) or minimal break-up (BUmin) groups. Tear film fluorescence decreased (median PI) and the percentage of TBU and DarkPix increased in all trials, with the rate significantly greater in the BU than the BUmin group (Mann-Whitney U test, P < 0.05). The rate of increasing discomfort during trials was highly correlated with the rate of decrease in median PI and developing TBU (Spearman's, r ≥ 0.70). Significant correlations were found between corneal fluorescence, MBI, and sensory measures. Concentration quenching of fluorescein dye with tear film thinning best explains decreasing tear film fluorescence during trials. This was highly correlated with increasing ocular discomfort, suggesting that both tear film thinning and TBU stimulate underlying corneal nerves, although TBU produced more rapid stimulation. Slow increases in tear film hyperosmolarity may cause the gradual increase in discomfort during slow tear film thinning, whereas the sharp increases in discomfort during TBU suggest a more complex stimulus.
Collins, Richard N; Bakkaus, Estelle; Carrière, Marie; Khodja, Hicham; Proux, Olivier; Morel, Jean-Louis; Gouget, Barbara
2010-04-15
The root-to-shoot transfer, localization, and chemical speciation of Co were investigated in a monocotyledon (Triticum aestivum L., wheat) and a dicotyledon (Lycopersicon esculentum M., tomato) plant species grown in nutrient solution at low (5 muM) and high (20 muM) Co(II) concentrations. Cobalt was measured in the roots and shoots by inductively coupled plasma-mass spectrometry. X-ray absorption spectroscopy measurements were used to identify the chemical structure of Co within the plants and Co distribution in the leaves was determined by micro-PIXE (particle induced X-ray emission). Although the root-to-shoot transport was higher for tomato plants exposed to excess Co, both plants appeared as excluders. The oxidation state of Co(II) was not transformed by either plant in the roots or shoots and Co appeared to be present as Co(II) in a complex with carboxylate containing organic acids. Cobalt was also essentially located in the vascular system of both plant species indicating that neither responded to Co toxicity via sequestration in epidermal or trichome tissues as has been observed for other metals in metal hyperaccumulating plants.
USB 3.0 readout and time-walk correction method for Timepix3 detector
NASA Astrophysics Data System (ADS)
Turecek, D.; Jakubek, J.; Soukup, P.
2016-12-01
The hybrid particle counting pixel detectors of Medipix family are well known. In this contribution we present new USB 3.0 based interface AdvaDAQ for Timepix3 detector. The AdvaDAQ interface is designed with a maximal emphasis to the flexibility. It is successor of FitPIX interface developed in IEAP CTU in Prague. Its modular architecture supports all Medipix/Timepix chips and all their different readout modes: Medipix2, Timepix (serial and parallel), Medipix3 and Timepix3. The high bandwidth of USB 3.0 permits readout of 1700 full frames per second with Timepix or 8 channel data acquisition from Timepix3 at frequency of 320 MHz. The control and data acquisition is integrated in a multiplatform PiXet software (MS Windows, Mac OS, Linux). In the second part of the publication a new method for correction of the time-walk effect in Timepix3 is described. Moreover, a fully spectroscopic X-ray imaging with Timepix3 detector operated in the ToT mode (Time-over-Threshold) is presented. It is shown that the AdvaDAQ's readout speed is sufficient to perform spectroscopic measurement at full intensity of radiographic setups equipped with nano- or micro-focus X-ray tubes.
Alwadani, Fahad; Morsi, Mohammed Saad
2012-01-01
To compare the surgical proficiency of medical students who underwent traditional training or virtual reality training for argon laser trabeculoplasty with the PixEye simulator. The cohort comprised of 47 fifth year male medical students from the College of Medicine, King Faisal University, Saudi Arabia. The cohort was divided into two groups: students (n = 24), who received virtual reality training (VR Group) and students (n = 23), who underwent traditional training (Control Group). After training, the students performed the trabeculoplasty procedure. All trainings were included concurrent power point presentations describing the details of the procedure. Evaluation of surgical performance was based on the following variables: missing the exact location with the laser, overtreatment, undertreatment and inadvertent laser shots to iris and cornea. The target was missed by 8% of the VR Group compared to 55% in the Control Group. Overtreatment and undertreatment was observed in 7% of the VR Group compared to 46% of the Control Group. Inadvertent laser application to the cornea or iris was performed by 4.5% of the VR Group compared to 34% of the Control Group. Virtual reality training on PixEye simulator may enhance the proficiency of medical students and limit possible surgical errors during laser trabeculoplasty. The authors have no financial interest in the material mentioned in this study.
NASA Astrophysics Data System (ADS)
Dosil Suárez, Álvaro; LHCb VELO Upgrade Group
2016-07-01
The upgrade of the LHCb experiment, planned for 2019, will transform the experiment to a trigger-less system reading out the full detector at 40 MHz event rate. All data reduction algorithms will be executed in a high-level software farm. The upgraded detector will run at luminosities of 2×1033 cm-2 s-1 and probe physics beyond the Standard Model in the heavy flavour sector with unprecedented precision. The Vertex Locator (VELO) is the silicon vertex detector surrounding the interaction region. The current detector will be replaced with a hybrid pixel system equipped with electronics capable of reading out at 40 MHz. The detector comprises silicon pixel sensors with 55×55 μm2 pitch, read out by the VeloPix ASIC, based on the TimePix/MediPix family. The hottest region will have pixel hit rates of 900 Mhits/s yielding a total data rate more than 3 Tbit/s for the upgraded VELO. The detector modules are located in a separate vacuum, separated from the beam vacuum by a thin custom made foil. The detector halves are retracted when the beams are injected and closed at stable beams, positioning the first sensitive pixel at 5.1 mm from the beams. The material budget will be minimised by the use of evaporative CO2 coolant circulating in microchannels within 400 μm thick silicon substrates.
Analysis of dinosaur samples by nuclear microscopy
NASA Astrophysics Data System (ADS)
Wu, Xiankang; Orlić, I.; Tang, S. M.; Wang, Yiming; Wang, Xiaohong; Zhu, Jieqing
1997-07-01
Several dinosaur bone and eggshell fossil samples unearthed at different sites in China were analyzed by means of nuclear microscopy. Concentrations and distributions of elements such as Na, Mg, Al, P, S, Ca, Cr, Mn, Fe, Cu, Zn, As, Br, Sr, Y, Ce, Pb and U, etc. were obtained for each sample. The results of quantitative PIXE and RBS analyses show unusually high concentrations of U and Ce in several samples obtained from a period near the K-T boundary (between Cretaceous and Tertiary periods, 65 million years ago), suggesting that some form of environmental pollution could be the cause of dinosaur extinction.
Ion beam analysis of ancient Mexican colored teeth from archaeological sites in Mexico City
NASA Astrophysics Data System (ADS)
Rodríguez-Fernández, L.; Ruvalcaba-Sil, J. L.; Ontalba-Salamanca, M. A.; Román-Berrelleza, J. A.; Gallardo, M. L.; Grimaldi, D. M.; de Lucio, O. G.; Miranda, J.
1999-04-01
Infant teeth with extremely rare colored enamel regions white, blue-gray and brown, have been analyzed by Particle Induced X-ray Emission (PIXE) and Rutherford Backscattering Spectrometry (RBS). The teeth were part of human being sacrifices to deities of the Mexica culture, Mexico, corresponding to the Late Post-classic period (1325-1521 A.D.). Comparisons to normal teeth from the same historical period indicate that the colored ones present larger mean amounts of Mn and Fe, while Zn and Sr do not differ too much. Possible inorganic compounds responsible for the different colorations are indicated.
Kumar, Ashok; Sidhu, Pardeep; Nautiyal, Jyoti; Rautray, T R; Sudarshan, M; Kumar, R; Singh, N; Garg, M L; Dhawan, D K
2007-01-01
Chemical composition of the aerosols is an important aspect of aerosol monitoring. The adverse effects on human heath due to different elements in aerosols depend on their concentrations. A comparative study of aerosol concentration and composition from an industrial town Mandi-Gobindgarh and a nearby (25 km away) non-industrial and comparatively less polluted town Morinda, in state Punjab (India) was carried out. Aerosol samples were analyzed by Particle Induced X-ray Emission (PIXE) technique at the Institute of Physics, Bhubaneshwar. Elemental concentrations were found to be much higher in Mandi-Gobindgarh as compared to Morinda. However, the large deviations from the mean concentrations, particularly in Mandi-Gobindgarh is suggestive of highly varying day to day industrial activity and changing weather conditions. Elements such as S, Br and Pb were found higher in the PM2.5 (particulate matter with = 2.5 microm aerodynamic diameter), which are related to burning of coal and oil in furnaces in Mandi-Gobindgarh. The elements related to natural dust such as K, Ca, Ti, Mn, and Fe are mainly distributed in PMcf (particulate matter with aerodynamic diameter between 2.5 and 10 microm) fraction in both the towns. High concentrations of Ti, Cr, Mn, Fe and Zn in the PMcf fraction from Mandi-Gobindgarh are likely due to the industrial activity of Steel rolling mills.
The external scanning proton microprobe of Firenze: A comprehensive description
NASA Astrophysics Data System (ADS)
Giuntini, L.; Massi, M.; Calusi, S.
2007-06-01
An external proton scanning microbeam setup is installed on the -30° line of the new 3 MV tandem accelerator in Firenze; the most relevant features of the line, such as detection setup for IBA measurements, target viewing system, beam diagnostic and transport are described here. With our facility we can work with a beam spot on sample better than 10 μm full-width half-maximum (FWHM) and an intensity of some nanoamperes. Standard beam exit windows are silicon nitride (Si 3N 4) TEM membranes, 100 nm thick and 0.5×0.5 mm 2 wide; we also successfully performed measurements using membranes 1×1 mm 2 wide, 100 nm thick, and 2×2 mm 2 wide, 200 and 500 nm thick. Exploiting the yield of Si X-rays produced by the beam in the exit window as an indirect measurement of the charge, a beam charge monitor system was implemented. The analytical capabilities of the microbeam have been extended by integrating a two-detector PIXE setup with BS and PIGE detectors; the external scanning proton microprobe in Firenze is thus a powerful instrument to fully characterize samples by ion beam analysis, through the simultaneous collection of PIXE, PIGE and BS elemental maps. Its characteristics can make it often competitive with traditional in vacuum microbeam for measurements of thick targets.
NASA Astrophysics Data System (ADS)
Gautret, P.; Ramboz, C.; de Wit, R.; Delarue, F.; Orange, F.; Sorieul, S.; Westall, F.
2012-04-01
Physico-chemical and biological micro-scale environmental parameters within microbial mats formed in hypersaline conditions favour the precipitation of minerals, such as carbonates. We used optical microscopy and the technique "Fluorescence Induction Relaxation » (FIRe) to differentiate the photosynthetic activity of oxygenic photosynthesisers (cyanobacteria) from anoxygenic photosynthesisers (Chloroflexus-like bacteria, CFB) in samples obtained in 2011. After this preliminary investigation, we characterised the elemental composition of the different species of microorganisms, their extracellular substances (EPS), and the minerals precipitated on their surface. This study was made in-situ by µ-PIXE using the nuclear microprobe of the AIFIRA platform (CEN Bordeaux-Gradignan ; protons of 1.5 or 3MeV). With this microprobe it is possible to map the distribution of elements occurring in quantities down to several ppm, a resolution that is particularly favourable for studying microorganisms. SEM observation of the same zones allowed us to localise exactly the microbial structures (cells, EPS) and minerals analysed by nuclear probe. We were thus able to document the differential S and P concentrations in the different microbial species, the CLB being richer in P. Note that the CLB filaments are < 1 µm in diameter. We were also able to demonstrate the anti-correlation of Ca and Mg in the minerals precipitated directly on the microorganisms and on their EPS. Thus we have shown the utility of these in situ, nano-scale methods in studying microbial structures consisting of different species with different metabolic activitie, and different functional groups on their cell walls and EPS implicated in the bioprecipitation of different kinds of minerals. Such features in ancient microbial mats could aid their interpretation and possibly the distinction between ancient oxygenic and anoxygenic mats.
Tests of commercial colour CMOS cameras for astronomical applications
NASA Astrophysics Data System (ADS)
Pokhvala, S. M.; Reshetnyk, V. M.; Zhilyaev, B. E.
2013-12-01
We present some results of testing commercial colour CMOS cameras for astronomical applications. Colour CMOS sensors allow to perform photometry in three filters simultaneously that gives a great advantage compared with monochrome CCD detectors. The Bayer BGR colour system realized in colour CMOS sensors is close to the astronomical Johnson BVR system. The basic camera characteristics: read noise (e^{-}/pix), thermal noise (e^{-}/pix/sec) and electronic gain (e^{-}/ADU) for the commercial digital camera Canon 5D MarkIII are presented. We give the same characteristics for the scientific high performance cooled CCD camera system ALTA E47. Comparing results for tests of Canon 5D MarkIII and CCD ALTA E47 show that present-day commercial colour CMOS cameras can seriously compete with the scientific CCD cameras in deep astronomical imaging.
Steimle, Timothy C; Wang, Hailing; Gengler, Jamie J; Stoll, Michael; Meijer, Gerard
2008-10-28
The Zeeman tuning of the P(1)(0) line (nu=17 568.35 cm(-1)) of the A (7)Pi-X (7)Sigma(+) (0,0) band of manganese monohydride, MnH, has been investigated. The laser induced fluorescence spectrum of a supersonic molecular beam sample was recorded at a resolution of approximately 40 MHz and with field strengths of up to 362.0 mT. The observed spectrum was successfully fitted using a traditional effective Zeeman Hamiltonian to determine an effective magnetic g-factor for the J=2 level of the F(1)-spin component of the A (7)Pi(v=0) state. Spectral predictions of the P(1)(0) line at field strengths used in magnetic trapping experiments are presented.
ALMA On the Move - ESO Awards Important Contract for the ALMA Project
NASA Astrophysics Data System (ADS)
2005-12-01
Only two weeks after awarding its largest-ever contract for the procurement of antennas for the Atacama Large Millimeter Array project (ALMA), ESO has signed a contract with Scheuerle Fahrzeugfabrik GmbH, a world-leader in the design and production of custom-built heavy-duty transporters, for the provision of two antenna transporting vehicles. These vehicles are of crucial importance for ALMA. ESO PR Photo 41a/05 ESO PR Photo 41a/05 The ALMA Transporter (Artist's Impression) [Preview - JPEG: 400 x 756 pix - 234k] [Normal - JPEG: 800 x 1512 pix - 700k] [Full Res - JPEG: 1768 x 3265 pix - 2.3M] Caption: Each of the ALMA transporters will be 10 m wide, 4.5 m high and 16 m long. "The timely awarding of this contract is most important to ensure that science operations can commence as planned," said ESO Director General Catherine Cesarsky. "This contract thus marks a further step towards the realization of the ALMA project." "These vehicles will operate in a most unusual environment and must live up to very strict demands regarding performance, reliability and safety. Meeting these requirements is a challenge for us, and we are proud to have been selected by ESO for this task," commented Hans-Jörg Habernegg, President of Scheuerle GmbH. ESO PR Photo 41b/05 ESO PR Photo 41b/05 Signing the Contract [Preview - JPEG: 400 x 572 pix - 234k] [Normal - JPEG: 800 x 1143 pix - 700k] [HiRes - JPEG: 4368 x 3056 pix - 2.3M] Caption: (left to right) Mr Thomas Riek, Vice-President of Scheuerle GmbH, Dr Catherine Cesarsky, ESO Director General and Mr Hans-Jörg Habernegg, President of Scheuerle GmbH. When completed on the high-altitude Chajnantor site in Chile, ALMA is expected to comprise more than 60 antennas, which can be placed in different locations on the plateau but which work together as one giant telescope. Changing the relative positions of the antennas and thus also the configuration of the array allows for different observing modes, comparable to using a zoom lens, offering different degrees of resolution and sky coverage as needed by the astronomers. The ALMA Antenna Transporters allow for moving the antennas between the different pre-defined antenna positions. They will also be used for transporting antennas between the maintenance area at 2900 m elevation and the "high site" at 5000 m above sea level, where the observations are carried out. Given their important functions, both for the scientific work and in transporting high-tech antennas with the required care, the vehicles must live up to very demanding operational requirements. Each transporter has a mass of 150 tonnes and is able to lift and transport antennas of 110 tonnes. They must be able to place the antennas on the docking pads with millimetric precision. At the same time, they must be powerful enough to climb 2000 m reliably and safely with their heavy and valuable load, putting extraordinary demands on the 500 kW diesel engines. This means negotiating a 28 km long high-altitude road with an average slope of 7 %. Finally, as they will be operated at an altitude with significantly reduced oxygen levels, a range of redundant safety devices protect both personnel and equipment from possible mishaps or accidents. The first transporter is scheduled to be delivered in the summer of 2007 to match the delivery of the first antennas to Chajnantor. The ESO contract has a value of approx. 5.5 m Euros.
Onizuka, Miho; Hoang, Huu; Kawato, Mitsuo; Tokuda, Isao T; Schweighofer, Nicolas; Katori, Yuichi; Aihara, Kazuyuki; Lang, Eric J; Toyama, Keisuke
2013-11-01
The inferior olive (IO) possesses synaptic glomeruli, which contain dendritic spines from neighboring neurons and presynaptic terminals, many of which are inhibitory and GABAergic. Gap junctions between the spines electrically couple neighboring neurons whereas the GABAergic synaptic terminals are thought to act to decrease the effectiveness of this coupling. Thus, the glomeruli are thought to be important for determining the oscillatory and synchronized activity displayed by IO neurons. Indeed, the tendency to display such activity patterns is enhanced or reduced by the local administration of the GABA-A receptor blocker picrotoxin (PIX) or the gap junction blocker carbenoxolone (CBX), respectively. We studied the functional roles of the glomeruli by solving the inverse problem of estimating the inhibitory (gi) and gap-junctional conductance (gc) using an IO network model. This model was built upon a prior IO network model, in which the individual neurons consisted of soma and dendritic compartments, by adding a glomerular compartment comprising electrically coupled spines that received inhibitory synapses. The model was used in the forward mode to simulate spike data under PIX and CBX conditions for comparison with experimental data consisting of multi-electrode recordings of complex spikes from arrays of Purkinje cells (complex spikes are generated in a one-to-one manner by IO spikes and thus can substitute for directly measuring IO spike activity). The spatiotemporal firing dynamics of the experimental and simulation spike data were evaluated as feature vectors, including firing rates, local variation, auto-correlogram, cross-correlogram, and minimal distance, and were contracted onto two-dimensional principal component analysis (PCA) space. gc and gi were determined as the solution to the inverse problem such that the simulation and experimental spike data were closely matched in the PCA space. The goodness of the match was confirmed by an analysis of variance (ANOVA) of the PCA scores between the experimental and simulation spike data. In the PIX condition, gi was found to decrease to approximately half its control value. CBX caused an approximately 30% decrease in gc from control levels. These results support the hypothesis that the glomeruli are control points for determining the spatiotemporal characteristics of olivocerebellar activity and thus may shape its ability to convey signals to the cerebellum that may be used for motor learning or motor control purposes. Copyright © 2013 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
2005-09-01
Large Population of Galaxies Found in the Young Universe with ESO's VLT The Universe was a more fertile place soon after it was formed than has previously been suspected. A team of French and Italian astronomers [1] made indeed the surprising discovery of a large and unknown population of distant galaxies observed when the Universe was only 10 to 30% its present age. ESO PR Photo 29a/05 ESO PR Photo 29a/05 New Population of Distant Galaxies [Preview - JPEG: 400 x 424 pix - 191k] [Normal - JPEG: 800 x 847 pix - 449k] [HiRes - JPEG: 2269 x 2402 pix - 2.0M] ESO PR Photo 29b/05 ESO PR Photo 29b/05 Average Spectra of Distant Galaxies [Preview - JPEG: 400 x 506 pix - 141k] [Normal - JPEG: 800 x 1012 pix - 320k] This breakthrough is based on observations made with the Visible Multi-Object Spectrograph (VIMOS) as part of the VIMOS VLT Deep Survey (VVDS). The VVDS started early 2002 on Melipal, one of the 8.2-m telescopes of ESO's Very Large Telescope Array [2]. In a total sample of about 8,000 galaxies selected only on the basis of their observed brightness in red light, almost 1,000 bright and vigorously star forming galaxies were discovered that were formed between 9 and 12 billion years ago (i.e. about 1,500 to 4,500 million years after the Big Bang). "To our surprise, says Olivier Le Fèvre, from the Laboratoire d'Astrophysique de Marseille (France) and co-leader of the VVDS project, "this is two to six times higher than had been found previously. These galaxies had been missed because previous surveys had selected objects in a much more restrictive manner than we did. And they did so to accommodate the much lower efficiency of the previous generation of instruments." While observations and models have consistently indicated that the Universe had not yet formed many stars in the first billion years of cosmic time, the discovery announced today by scientists calls for a significant change in this picture. The astronomers indeed find that stars formed two to three times faster than previously estimated. "These observations will demand a profound reassessment of our theories of the formation and evolution of galaxies in a changing Universe", says Gianpaolo Vettolani, the other co-leader of the VVDS project, working at INAF-IRA in Bologna (Italy). These results are reported in the September 22 issue of the journal Nature (Le Fèvre et al., "A large population of galaxies 9 to 12 billion years back in the life of the Universe").
DOE Office of Scientific and Technical Information (OSTI.GOV)
Key, Hanna M.; Dydio, Paweł; Liu, Zhennan
Enzymes catalyze organic transformations with exquisite levels of selectivity, including chemoselectivity, stereoselectivity, and substrate selectivity, but the types of reactions catalyzed by enzymes are more limited than those of chemical catalysts. Thus, the convergence of chemical catalysis and biocatalysis can enable enzymatic systems to catalyze abiological reactions with high selectivity. Recently, we disclosed artificial enzymes constructed from the apo form of heme proteins and iridium porphyrins that catalyze the insertion of carbenes into a C-H bond. Here, we postulated that the same type of Ir(Me)-PIX enzymes could catalyze the cyclopropanation of a broad range of alkenes with control of multiplemore » modes of selectivity. Here, we report the evolution of artificial enzymes that are highly active and highly stereoselective for the addition of carbenes to a wide range of alkenes. These enzymes catalyze the cyclopropanation of terminal and internal, activated and unactivated, electron-rich and electron-deficient, conjugated and nonconjugated alkenes. In particular, Ir(Me)-PIX enzymes derived from CYP119 catalyze highly enantio- and diastereoselective cyclopropanations of styrene with ±98% ee, > 70:1 dr, > 75% yield, and ~10,000 turnovers (TON), as well as 1,2-disubstituted styrenes with up to 99% ee, 35:1 dr, and 54% yield. Moreover, Ir(Me)-PIX enzymes catalyze cyclopropanation of internal, unactivated alkenes with up to 99% stereoselectivity, 76% yield, and 1300 TON. They also catalyze cyclopropanation of natural products with diastereoselectivities that are complementary to those attained with standard transition metal catalysts. Finally, Ir(Me)-PIX P450 variants react with substrate selectivity that is reminiscent of natural enzymes; they react preferentially with less reactive internal alkenes in the presence of more reactive terminal alkenes. Altogether, the studies reveal the suitability of Ir-containing P450s to combine the broad reactivity and substrate scope of transition metal catalysts with the exquisite selectivity of enzymes, generating catalysts that enable reactions to occur with levels and modes of activity and selectivity previously unattainable with natural enzymes or transition metal complexes alone.« less
Key, Hanna M.; Dydio, Paweł; Liu, Zhennan; ...
2017-04-01
Enzymes catalyze organic transformations with exquisite levels of selectivity, including chemoselectivity, stereoselectivity, and substrate selectivity, but the types of reactions catalyzed by enzymes are more limited than those of chemical catalysts. Thus, the convergence of chemical catalysis and biocatalysis can enable enzymatic systems to catalyze abiological reactions with high selectivity. Recently, we disclosed artificial enzymes constructed from the apo form of heme proteins and iridium porphyrins that catalyze the insertion of carbenes into a C-H bond. Here, we postulated that the same type of Ir(Me)-PIX enzymes could catalyze the cyclopropanation of a broad range of alkenes with control of multiplemore » modes of selectivity. Here, we report the evolution of artificial enzymes that are highly active and highly stereoselective for the addition of carbenes to a wide range of alkenes. These enzymes catalyze the cyclopropanation of terminal and internal, activated and unactivated, electron-rich and electron-deficient, conjugated and nonconjugated alkenes. In particular, Ir(Me)-PIX enzymes derived from CYP119 catalyze highly enantio- and diastereoselective cyclopropanations of styrene with ±98% ee, > 70:1 dr, > 75% yield, and ~10,000 turnovers (TON), as well as 1,2-disubstituted styrenes with up to 99% ee, 35:1 dr, and 54% yield. Moreover, Ir(Me)-PIX enzymes catalyze cyclopropanation of internal, unactivated alkenes with up to 99% stereoselectivity, 76% yield, and 1300 TON. They also catalyze cyclopropanation of natural products with diastereoselectivities that are complementary to those attained with standard transition metal catalysts. Finally, Ir(Me)-PIX P450 variants react with substrate selectivity that is reminiscent of natural enzymes; they react preferentially with less reactive internal alkenes in the presence of more reactive terminal alkenes. Altogether, the studies reveal the suitability of Ir-containing P450s to combine the broad reactivity and substrate scope of transition metal catalysts with the exquisite selectivity of enzymes, generating catalysts that enable reactions to occur with levels and modes of activity and selectivity previously unattainable with natural enzymes or transition metal complexes alone.« less
Busse, B; Niecke, M; Püschel, K; Delling, G; Katzer, A; Hahn, M
2007-01-01
Periprosthetic tissue was analysed by the combination of different investigation techniques without destruction. The localisation and geometry of polyethylene abrasion particles were determined quantitatively to differentiate between abrasion due to function and abrasion due to implant loosening. Non-polyethylene particles from implant components which contaminate the tissue were micro-analytically measured. The results will help us to understand loosening mechanisms and thus lead to implant optimisations. A non-destructive particle analysis using highly sensitive proton-induced X-ray emission (PIXE) was developed to achieve a better histological allocation. Five autopsy cases with firmly fitting hip endoprosthesis (2 x Endo-Modell Mark III, 1 x St. Georg Mark II, LINK, Germany; 2 x Spongiosa Metal II, ESKA, Germany) were prepared as ground tissue specimens. Wear investigations were accomplished with a combined application of different microscopic techniques and microanalysis. The abrasion due to implant loosening was histologically evaluated on 293 loosened cup implants (St. Georg Mark II, LINK, Germany). Wear particles are heterogeneously distributed in the soft tissue. In cases of cemented prostheses, cement particles are dominating whereas metal particles could rarely be detected. The concentration of the alloy constituent cobalt (Co) is increased in the mineralised bone tissue. The measured co-depositions depend on the localisation and/or lifetime of an implant. Functional polyethylene (PE) abrasion needs to be differentiated from PE abrasion of another genesis (loosening, impingement) morphologically and by different tissue reactions. In the past a reduction of abrasion was targeted primarily by the optimisation of the bearing surfaces and tribology. The interpretation of our findings indicates that different mechanisms of origin in terms of tissue contamination with wear debris and the alloy should be included in the improvement of implants or implantation techniques.
NASA Astrophysics Data System (ADS)
Usov, I. O.; Arendt, P. N.; Foltyn, S. R.; Stan, L.; DePaula, R. F.; Holesinger, T. G.
2010-06-01
One of the crucial steps in the second generation high temperature superconducting wire program was development of the buffer-layer architecture. The architecture designed at the Superconductivity Technology Center at Los Alamos National Laboratory consists of several oxide layers wherein each layer plays a specific role, namely: nucleation layer, diffusion barrier, biaxially textured template, and intermediate layer providing a suitable lattice match to the superconducting Y 1Ba 2Cu 3O 7 (YBCO) compound. This report demonstrates how a wide range of ion beam analysis techniques (SIMS, RBS, channeling, PIXE, PIGE, NRA and ERD) was employed for analysis of each buffer layer and the YBCO film. These results assisted in understanding of a variety of physical processes occurring during the buffer layer fabrication and helped to optimize the buffer-layer architecture as a whole.
Quantification of lithium at ppm level in geological samples using nuclear reaction analysis.
De La Rosa, Nathaly; Kristiansson, Per; Nilsson, E J Charlotta; Ros, Linus; Pallon, Jan; Skogby, Henrik
2018-01-01
Proton-induced reaction (p,α) is one type of nuclear reaction analysis (NRA) suitable especially for light element quantification. In the case of lithium quantification presented in this work, accelerated protons with an energy about of 850 keV were used to induce the 7 Li(p,α) 4 He reaction in standard reference and geological samples such as tourmaline and other Li-minerals. It is shown that this technique for lithium quantification allowed for measurement of concentrations down below one ppm. The possibility to relate the lithium content with the boron content in a single analysis was also demonstrated using tourmaline samples, both in absolute concentration and in lateral distribution. In addition, Particle induced X-ray emission (PIXE) was utilized as a complementary IBA technique for simultaneous mapping of elements heavier than sodium.
Quantitative mapping of intracellular cations in the human amniotic membrane
NASA Astrophysics Data System (ADS)
Moretto, Ph.; Llabador, Y.; Simonoff, M.; Razafindrabe, L.; Bara, M.; Guiet-Bara, A.
1993-05-01
The effect of magnesium and taurine on the permeability of cell membranes to monovalent cations has been investigated using the Bordeaux nuclear microprobe. PIXE and RBS techniques have been used to provide quantitative measurements and ion distributions in the isolated amniotic membrane. This physiological model for cellular exchanges allowed us to reveal the distribution of most elements involved in cellular pathways and the modifications under different experimental conditions of incubation in physiological fluids. The PIXE microanalysis provided an original viewpoint on these mechanisms. Following this first study, the amnion compact lamina was found to play a role which was not, up to now, taken into account in the interpretation of electrophysiological experimentations. The release of some ionic species, such as K +, from the epithelial cells, during immersion in isotonic fluids, could have been hitherto underestimated.
Roman onyx glass: A study of production recipes and colorants, using PIXE spectrometry
NASA Astrophysics Data System (ADS)
Fleming, S. J.; Swann, C. P.
1994-03-01
The most attractive Roman glass produced during the latter half of the 1st century B.C. was mosaic ware — vessels and dishes molded from arrays of composite, multi-colored canes which create abstract floral and geometric designs. We have studied a range of such vessels, all of them colored amber and white in a way which was intended to imitate elite vessels that were carved from onyx stone. We have differentiated three ways in which onyx patterns were achieved in this glass. Taking advantage of the spatial resolution and detection sensitivity of PIXE spectrometry, we have studied the "recipes" for colorants used in these onyx patterns, thus raising the notion that each one may have been fashionable in just certain regions of the Roman World, and/or in vogue only during a certain time period.
Tang dynasty (618-907) bowl measured with PIXE
NASA Astrophysics Data System (ADS)
Laitinen, M.; Käyhkö, M.; Hahn, G.; von Uexküll-Güldenband, N.; Sajavaara, T.
2017-09-01
Brownish bowl originating from an underwater shipwreck located near Belitung island in the Java Sea, some 600 km south-east from Singapore, has been measured with particle induced X-ray emission. This study was a pilot project for the - now a spin-off company - Recenart research team where one target was to evaluate the authenticity of the different type of art objects. PIXE measurements were done from three different material positions from a single bowl received from a customer. These locations were categorized as a bluish/greenish pigment (under glaze), thick glaze and the body clay. When the obtained data was compared to the other references from different dynasties and kiln sites, the closest match was indeed the Tang dynasty, Tongguan/Ghangsha kiln-site potsherds - from where the bowl in question was also suspected to originate.
An Apparatus For Student Projects Using External-Beam PIXE And PIGE
NASA Astrophysics Data System (ADS)
Correll, Francis D.; Edsall, Douglas W.; DePooter, Katherine A.; Maskell, Nicholas D.; Vanhoy, Jeffrey R.
2011-06-01
We recently installed a simple endstation at the Naval Academy Tandem Accelerator Laboratory to support student projects using external-beam PIXE and PIGE. It consists of a short, graphite-lined beamline extension with a thin window, an interlocked box that surrounds the target, detectors for x- and gamma rays, provision for flooding the target with helium gas, easily changed x-ray absorbers, and a compact video camera for monitoring the position of the beam spot. We used this system to measure the elemental composition of colonial-era architectural materials, principally bricks and mortar, from James Madison's Montpelier, the reconstructed Virginia estate of the fourth President of the United States. We describe the design and construction of the system, relate some of our experiences using it, and present some preliminary data from our investigations.
SymPix: A Spherical Grid for Efficient Sampling of Rotationally Invariant Operators
NASA Astrophysics Data System (ADS)
Seljebotn, D. S.; Eriksen, H. K.
2016-02-01
We present SymPix, a special-purpose spherical grid optimized for efficiently sampling rotationally invariant linear operators. This grid is conceptually similar to the Gauss-Legendre (GL) grid, aligning sample points with iso-latitude rings located on Legendre polynomial zeros. Unlike the GL grid, however, the number of grid points per ring varies as a function of latitude, avoiding expensive oversampling near the poles and ensuring nearly equal sky area per grid point. The ratio between the number of grid points in two neighboring rings is required to be a low-order rational number (3, 2, 1, 4/3, 5/4, or 6/5) to maintain a high degree of symmetries. Our main motivation for this grid is to solve linear systems using multi-grid methods, and to construct efficient preconditioners through pixel-space sampling of the linear operator in question. As a benchmark and representative example, we compute a preconditioner for a linear system that involves the operator \\widehat{{\\boldsymbol{D}}}+{\\widehat{{\\boldsymbol{B}}}}T{{\\boldsymbol{N}}}-1\\widehat{{\\boldsymbol{B}}}, where \\widehat{{\\boldsymbol{B}}} and \\widehat{{\\boldsymbol{D}}} may be described as both local and rotationally invariant operators, and {\\boldsymbol{N}} is diagonal in the pixel domain. For a bandwidth limit of {{\\ell }}{max} = 3000, we find that our new SymPix implementation yields average speed-ups of 360 and 23 for {\\widehat{{\\boldsymbol{B}}}}T{{\\boldsymbol{N}}}-1\\widehat{{\\boldsymbol{B}}} and \\widehat{{\\boldsymbol{D}}}, respectively, compared with the previous state-of-the-art implementation.
Poulin, Kathy L; Lanthier, Robert M; Smith, Adam C; Christou, Carin; Risco Quiroz, Milagros; Powell, Karen L; O'Meara, Ryan W; Kothary, Rashmi; Lorimer, Ian A; Parks, Robin J
2010-10-01
Adenovirus (Ad) vectors are the most commonly used system for gene therapy applications, due in part to their ability to infect a wide array of cell types and tissues. However, many therapies would benefit from the ability to target the Ad vector only to specific cells, such as tumor cells for cancer gene therapy. In this study, we investigated the utility of capsid protein IX (pIX) as a platform for the presentation of single-chain variable-fragment antibodies (scFv) and single-domain antibodies (sdAb) for virus retargeting. We show that scFv can be displayed on the capsid through genetic fusion to native pIX but that these molecules fail to retarget the virus, due to improper folding of the scFv. Redirecting expression of the fusion protein to the endoplasmic reticulum (ER) results in correct folding of the scFv and allows it to recognize its epitope; however, ER-targeted pIX-scFv was incorporated into the Ad capsid at a very low level which was not sufficient to retarget virus infection. In contrast, a pIX-sdAb construct was efficiently incorporated into the Ad capsid and enhanced virus infection of cells expressing the targeted receptor. Taken together, our data indicate that pIX is an effective platform for presentation of large targeting polypeptides on the surface of the virus capsid, but the nature of the ligand can significantly affect its association with virions.
NASA Astrophysics Data System (ADS)
2001-04-01
A Window towards the Distant Universe Summary The Osservatorio Astronomico Capodimonte Deep Field (OACDF) is a multi-colour imaging survey project that is opening a new window towards the distant universe. It is conducted with the ESO Wide Field Imager (WFI) , a 67-million pixel advanced camera attached to the MPG/ESO 2.2-m telescope at the La Silla Observatory (Chile). As a pilot project at the Osservatorio Astronomico di Capodimonte (OAC) [1], the OACDF aims at providing a large photometric database for deep extragalactic studies, with important by-products for galactic and planetary research. Moreover, it also serves to gather experience in the proper and efficient handling of very large data sets, preparing for the arrival of the VLT Survey Telescope (VST) with the 1 x 1 degree 2 OmegaCam facility. PR Photo 15a/01 : Colour composite of the OACDF2 field . PR Photo 15b/01 : Interacting galaxies in the OACDF2 field. PR Photo 15c/01 : Spiral galaxy and nebulous object in the OACDF2 field. PR Photo 15d/01 : A galaxy cluster in the OACDF2 field. PR Photo 15e/01 : Another galaxy cluster in the OACDF2 field. PR Photo 15f/01 : An elliptical galaxy in the OACDF2 field. The Capodimonte Deep Field ESO PR Photo 15a/01 ESO PR Photo 15a/01 [Preview - JPEG: 400 x 426 pix - 73k] [Normal - JPEG: 800 x 851 pix - 736k] [Hi-Res - JPEG: 3000 x 3190 pix - 7.3M] Caption : This three-colour image of about 1/4 of the Capodimonte Deep Field (OACDF) was obtained with the Wide-Field Imager (WFI) on the MPG/ESO 2.2-m telescope at the la Silla Observatory. It covers "OACDF Subfield no. 2 (OACDF2)" with an area of about 35 x 32 arcmin 2 (about the size of the full moon), and it is one of the "deepest" wide-field images ever obtained. Technical information about this photo is available below. With the comparatively few large telescopes available in the world, it is not possible to study the Universe to its outmost limits in all directions. Instead, astronomers try to obtain the most detailed information possible in selected viewing directions, assuming that what they find there is representative for the Universe as a whole. This is the philosophy behind the so-called "deep-field" projects that subject small areas of the sky to intensive observations with different telescopes and methods. The astronomers determine the properties of the objects seen, as well as their distances and are then able to obtain a map of the space within the corresponding cone-of-view (the "pencil beam"). Recent, successful examples of this technique are the "Hubble Deep Field" (cf. ESO PR Photo 26/98 ) and the "Chandra Deep Field" ( ESO PR 05/01 ). In this context, the Capodimonte Deep Field (OACDF) is a pilot research project, now underway at the Osservatorio Astronomico di Capodimonte (OAC) in Napoli (Italy). It is a multi-colour imaging survey performed with the Wide Field Imager (WFI) , a 67-million pixel (8k x 8k) digital camera that is installed at the 2.2-m MPG/ESO Telescope at ESO's La Silla Observatory in Chile. The scientific goal of the OACDF is to provide an important database for subsequent extragalactic, galactic and planetary studies. It will allow the astronomers at OAC - who are involved in the VLT Survey Telescope (VST) project - to gain insight into the processing (and use) of the large data flow from a camera similar to, but four times smaller than the OmegaCam wide-field camera that will be installed at the VST. The field selection for the OACDF was based on the following criteria: * There must be no stars brighter than about 9th magnitude in the field, in order to avoid saturation of the CCD detector and effects from straylight in the telescope and camera. No Solar System planets should be near the field during the observations; * It must be located far from the Milky Way plane (at high galactic latitude) in order to reduce the number of galactic stars seen in this direction; * It must be located in the southern sky in order to optimize observing conditions (in particular, the altitude of the field above the horizon), as seen from the La Silla and Paranal sites; * There should be little interstellar material in this direction that may obscure the view towards the distant Universe; * Observations in this field should have been made with the Hubble Space Telescope (HST) that may serve for comparison and calibration purposes. Based on these criteria, the astronomers selected a field measuring about 1 x 1 deg 2 in the southern constellation of Corvus (The Raven). This is now known as the Capodimonte Deep Field (OACDF) . The above photo ( PR Photo 15a/01 ) covers one-quarter of the full field (Subfield No. 2 - OACDF2) - some of the objects seen in this area are shown below in more detail. More than 35,000 objects have been found in this area; the faintest are nearly 100 million fainter than what can be perceived with the unaided eye in the dark sky. Selected objects in the Capodimonte Deep Field ESO PR Photo 15b/01 ESO PR Photo 15b/01 [Preview - JPEG: 400 x 435 pix - 60k] [Normal - JPEG: 800 x 870 pix - 738k] [Hi-Res - JPEG: 3000 x 3261 pix - 5.1M] Caption : Enlargement of the interacting galaxies that are seen in the upper left corner of the OACDF2 field shown in PR Photo 15a/01 . The enlargement covers 1250 x 1130 WFI pixels (1 pixel = 0.24 arcsec), or about 5.0 x 4.5 arcmin 2 in the sky. The lower spiral is itself an interactive double. ESO PR Photo 15c/01 ESO PR Photo 15c/01 [Preview - JPEG: 557 x 400 pix - 93k] [Normal - JPEG: 1113 x 800 pix - 937k] [Hi-Res - JPEG: 3000 x 2156 pix - 4.0M] Caption : Enlargement of a spiral galaxy and a nebulous object in this area. The field shown covers 1250 x 750 pixels, or about 5 x 3 arcmin 2 in the sky. Note the very red objects next to the two bright stars in the lower-right corner. The colours of these objects are consistent with those of spheroidal galaxies at intermediate distances (redshifts). ESO PR Photo 15d/01 ESO PR Photo 15d/01 [Preview - JPEG: 400 x 530 pix - 68k] [Normal - JPEG: 800 x 1060 pix - 870k] [Hi-Res - JPEG: 2768 x 3668 pix - 6.2M] Caption : A further enlargement of a galaxy cluster of which most members are located in the north-east quadrant (upper left) and have a reddish colour. The nebulous object to the upper left is a dwarf galaxy of spheroidal shape. The red object, located near the centre of the field and resembling a double star, is very likely a gravitational lens [2]. Some of the very red, point-like objects in the field may be distant quasars, very-low mass stars or, possibly, relatively nearby brown dwarf stars. The field shown covers 1380 x 1630 pixels, or 5.5 x 6.5 arcmin 2. ESO PR Photo 15e/01 ESO PR Photo 15e/01 [Preview - JPEG: 400 x 418 pix - 56k] [Normal - JPEG: 800 x 835 pix - 700k] [Hi-Res - JPEG: 3000 x 3131 pix - 5.0M] Caption : Enlargement of a moderately distant galaxy cluster in the south-east quadrant (lower left) of the OACDF2 field. The field measures 1380 x 1260 pixels, or about 5.5 x 5.0 arcmin 2 in the sky. ESO PR Photo 15f/01 ESO PR Photo 15f/01 [Preview - JPEG: 449 x 400 pix - 68k] [Normal - JPEG: 897 x 800 pix - 799k] [Hi-Res - JPEG: 3000 x 2675 pix - 5.6M] Caption : Enlargement of the elliptical galaxy that is located to the west (right) in the OACDF2 field. The numerous tiny objects surrounding the galaxy may be globular clusters. The fuzzy object on the right edge of the field may be a dwarf spheroidal galaxy. The size of the field is about 6 x 5 arcmin 2. Technical Information about the OACDF Survey The observations for the OACDF project were performed in three different ESO periods (18-22 April 1999, 7-12 March 2000 and 26-30 April 2000). Some 100 Gbyte of raw data were collected during each of the three observing runs. The first OACDF run was done just after the commissioning of the ESO-WFI. The observational strategy was to perform a 1 x 1 deg 2 short-exposure ("shallow") survey and then a 0.5 x 1 deg 2 "deep" survey. The shallow survey was performed in the B, V, R and I broad-band filters. Four adjacent 30 x 30 arcmin 2 fields, together covering a 1 x 1 deg 2 field in the sky, were observed for the shallow survey. Two of these fields were chosen for the 0.5 x 1 deg 2 deep survey; OACDF2 shown above is one of these. The deep survey was performed in the B, V, R broad-bands and in other intermediate-band filters. The OACDF data are fully reduced and the catalogue extraction has started. A two-processor (500 Mhz each) DS20 machine with 100 Gbyte of hard disk, specifically acquired at the OAC for WFI data reduction, was used. The detailed guidelines of the data reduction, as well as the catalogue extraction, are reported in a research paper that will appear in the European research journal Astronomy & Astrophysics . Notes [1]: The team members are: Massimo Capaccioli, Juan M. Alcala', Roberto Silvotti, Magda Arnaboldi, Vincenzo Ripepi, Emanuella Puddu, Massimo Dall'Ora, Giuseppe Longo and Roberto Scaramella . [2]: This is a preliminary result by Juan Alcala', Massimo Capaccioli, Giuseppe Longo, Mikhail Sazhin, Roberto Silvotti and Vincenzo Testa , based on recent observations with the Telescopio Nazionale Galileo (TNG) which show that the spectra of the two objects are identical. Technical information about the photos PR Photo 15a/01 has been obtained by the combination of the B, V, and R stacked images of the OACDF2 field. The total exposure times in the three bands are 2 hours in B and V (12 ditherings of 10 min each were stacked to produce the B and V images) and 3 hours in R (13 ditherings of 15 min each). The mosaic images in the B and V bands were aligned relative to the R-band image and adjusted to a logarithmic intensity scale prior to the combination. The typical seeing was of the order of 1 arcsec in each of the three bands. Preliminary estimates of the three-sigma limiting magnitudes in B, V and R indicate 25.5, 25.0 and 25.0, respectively. More than 35,000 objects are detected above the three-sigma level. PR Photos 15b-f/01 display selected areas of the field shown in PR Photo 15a/01 at the original WFI scale, hereby also demonstrating the enormous amount of information contained in these wide-field images. In all photos, North is up and East is left.
NASA Astrophysics Data System (ADS)
Russell, John L.; Campbell, John L.; Boyd, Nicholas I.; Dias, Johnny F.
2018-02-01
The newly developed GUMAP software creates element maps from OMDAQ list mode files, displays these maps individually or collectively, and facilitates on-screen definitions of specified regions from which a PIXE spectrum can be built. These include a free-hand region defined by moving the cursor. The regional charge is entered automatically into the spectrum file in a new GUPIXWIN-compatible format, enabling a GUPIXWIN analysis of the spectrum. The code defaults to the OMDAQ dead time treatment but also facilitates two other methods for dead time correction in sample regions with count rates different from the average.
Analysis of garnets from the archaeological sites in Slovenia
NASA Astrophysics Data System (ADS)
Šmit, Ž.; Fajfar, H.; Jeršek, M.; Knific, T.; Lux, J.
2014-06-01
Garnets (62 individual stones) originating from the Migration Period cemeteries and hilltop settlements in Slovenia were analyzed by the combined PIXE/PIGE method for their chemical composition. Typologically, the analyzed stones may be classified as almandines originating from the sites in India, belonging to types I and II according to Calligaro. A smaller group of pyraldines intermediate between almandines and pyropes was also determined; identified as type III, their source is most likely in Sri Lanka. No garnets from Bohemia (Czech Republic) have been discovered, which may be related to important political changes in the 7th c. AD, induced by Slavic and Avaric migrations.
Iba Techniques to Study Renaissance Pottery Techniques
NASA Astrophysics Data System (ADS)
Bouquillon, A.; Castaing, J.; Salomon, J.; Zucchiatti, A.; Lucarelli, F.; Mando, P. A.; Prati, P.; Lanterna, G.; Vaccari, M. G.
2001-09-01
The application of Ion Beam Analysis, associated to Scanning Electron Microscopy is examined in connection with an extensive program on structural and chemical analyses of glazed terracotta's from the Italian Renaissance, launched by a French-Italian collaboration in the framework of the European COST-G1 scientific action. The objectives of the collaboration are reviewed. The compatibility of data from different specimen and various laboratories are discussed. Examples of the PIXE and statistical analyses on some artefacts of the "Robbiesche" type, supplied by the Louvre Museum of Paris and the Opificio delle Pietre Dure of Florence, are given to illustrate the performances of IBA in this particular field.
NASA Astrophysics Data System (ADS)
Balzan, S.; Buoso, M. C.; Ceccato, D.; De Poli, M.; Giaccone, V.; Moschini, G.; Novelli, E.; Olabanji, S. O.; Passi, P.; Tepedino, V.
2004-06-01
Nowadays, the food safety and the related health risks for humans are a major issue. It has become a priority to ensure the health and well-being of the population through the better scientific understanding of the food intake influence. A frequently found harmful feature of human diet is the simultaneous presence in food stuff of both essential and toxic elements. A significant example of this situation is represented by horse meat. The aim of this survey is to evaluate the elemental content of muscular, hepatic and renal tissues of horses bred in different countries of the East of Europe and slaughtered in Italy. The studied population consisted of about 100 individuals; the sampling period, coinciding with the highest market request, was extended from November to March. Freeze dried tissues were pelletized and carbon coated prior to analysis. The samples were analyzed using Particle Induced X-ray Emission (PIXE) technique at the AN2000 van de Graaff accelerator of the INFN-National Laboratories of Legnaro. The accuracy of the results was verified using certified standard reference materials prepared and measured in the same experimental conditions. Results have highlighted the noble nutritional values of horse muscular tissue in terms of iron, zinc and calcium content. Cadmium was staidly identified in horse kidneys, with an average concentration of 257 μg/g on dried matter, while in liver it was sporadically present.
Computer simulation of the CSPAD, ePix10k, and RayonixMX170HS X-ray detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tina, Adrienne
2015-08-21
The invention of free-electron lasers (FELs) has opened a door to an entirely new level of scientific research. The Linac Coherent Light Source (LCLS) at SLAC National Accelerator Laboratory is an X-ray FEL that houses several instruments, each with its own unique X-ray applications. This light source is revolutionary in that while its properties allow for a whole new range of scientific opportunities, it also poses numerous challenges. For example, the intensity of a focused X-ray beam is enough to damage a sample in one mere pulse; however, the pulse speed and extreme brightness of the source together are enoughmore » to obtain enough information about that sample, so that no further measurements are necessary. An important device in the radiation detection process, particularly for X-ray imaging, is the detector. The power of the LCLS X-rays has instigated a need for better performing detectors. The research conducted for this project consisted of the study of X-ray detectors to imitate their behaviors in a computer program. The analysis of the Rayonix MX170-HS, CSPAD, and ePix10k in particular helped to understand their properties. This program simulated the interaction of X-ray photons with these detectors to discern the patterns of their responses. A scientist’s selection process of a detector for a specific experiment is simplified from the characterization of the detectors in the program.« less
Dependence of precipitation of trace elements on pH in standard water
NASA Astrophysics Data System (ADS)
Verma, Shivcharan; Mohanty, Biraja P.; Singh, K. P.; Behera, B. R.; Kumar, Ashok
2018-04-01
The present work aimed to study the dependence of precipitation of trace elements on the pH of solution. A standard solution was prepared by using ultrapure deionized water (18.2 MΩ/cm) as the solvent and 11 water-soluble salts having different elements as solutes. Five samples of different pH values (2 acidic, 2 basic, and 1 neutral) were prepared from this standard solution. Sodium-diethyldithiocarbamate was used as the chelating agent to precipitate the metal ions present in these samples of different pH values. The targets were prepared by collecting these precipitates on mixed cellulose esters filter of 0.4 μm pore size by vacuum filtration. Elemental analysis of these targets was performed by particle-induced X-ray emission (PIXE) using 2.7 MeV protons from the single Dee variable energy cyclotron at Panjab University, Chandigarh, India. PIXE data were analyzed using GUPIXWIN software. For most of the elements, except Hg with oxidation state +2, such as Co, Ni, Zn, Ba, and Cd, a general trend of enhancement in precipitation was observed with the increase in pH. However, for other elements such as V, As, Mo, Ag, and Bi, which have oxidation state other than +2, no definite pattern was observed. Precipitation of Ba and As using this method was negligible at all five pH values. From these results, it can be concluded that the precipitation and recovery of elements depend strongly on the pH of the water sample.
Monitoring Ion Track Formation Using In Situ RBS/c, ToF-ERDA, and HR-PIXE
NASA Astrophysics Data System (ADS)
Karlušić, Marko; Fazinić, Stjepko; Siketić, Zdravko; Tadić, Tonči; Cosic, Donny; Božičević-Mihalić, Iva; Zamboni, Ivana; Jakšić, Milko; Schleberger, Marika
2017-09-01
The aim of this work is to investigate feasibility of the ion beam analysis techniques for monitoring swift heavy ion track formation. First, use of the in situ Rutherford backscattering spectroscopy in channeling mode to observe damage build-up in quartz SiO2 after MeV heavy ion irradiation is demonstrated. Second, new results of the in situ grazing incidence time-of-flight elastic recoil detection analysis used for monitoring the surface elemental composition during ion tracks formation in various materials are presented. Ion tracks were found on SrTiO3, quartz SiO2, a-SiO2 and muscovite mica surfaces by atomic force microscopy, but in contrast to our previous studies on GaN and TiO2, surface stoichiometry remained unchanged.
Speciation and distribution of arsenic and localization of nutrients in rice grains
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lombi, E.; Scheckel, K.G.; Pallon, J.
2012-09-05
Arsenic (As) contamination of rice grains and the generally low concentration of micronutrients in rice have been recognized as a major concern for human health. Here, we investigated the speciation and localization of As and the distribution of (micro)nutrients in rice grains because these are key factors controlling bioavailability of nutrients and contaminants. Bulk total and speciation analyses using high-pressure liquid chromatography (HPLC)-inductively coupled plasma mass spectrometry (ICP-MS) and X-ray absorption near-edge spectroscopy (XANES) was complemented by spatially resolved microspectroscopic techniques ({mu}-XANES, {mu}-X-ray fluorescence ({mu}-XRF) and particle induced X-ray emission (PIXE)) to investigate both speciation and distribution of As andmore » localization of nutrients in situ. The distribution of As and micronutrients varied between the various parts of the grains (husk, bran and endosperm) and was characterized by element-specific distribution patterns. The speciation of As in bran and endosperm was dominated by As(III)-thiol complexes. The results indicate that the translocation from the maternal to filial tissues may be a bottleneck for As accumulation in the grain. Strong similarities between the distribution of iron (Fe), manganese (Mn) and phosphorus (P) and between zinc (Zn) and sulphur (S) may be indicative of complexation mechanisms in rice grains.« less
On the incorporation of trace elements into human hair measured with micro-PIXE
NASA Astrophysics Data System (ADS)
Bos, A. J. J.; Van Der Stap, C. C. A. H.; Valković, V.; Vis, R. D.; Verheul, H.
1984-04-01
A study has been made on the incorporation of trace elements into human hair by measuring concentration distributions across hair diameters of selected samples using the Amsterdam proton microbeam. Because hair is considered as a recording filament, reflecting metabolic changes over a period of time, a hair of a young mother was plucked 4 months after delivery of her first child. No change in the Zn and Cu concentrations correlated with the period of gestation was observed. A strong increase of Ca in the distal end must be attributed to outside contamination. From a study of a hair root, including the root sheaths, it is found that the method of incorporation of sulfur (minor element) differs strikingly from the behaviour of the trace elements Zn, Cu, Fe and Ca. The Zn and Cu distributions provide evidence of a, not yet reported, transversal transcellular input route, in which the root sheaths play an important role. From the results it is deduced that Zn and Cu seem to be distributed homogeneously by nature, while Fe, present at a high level in the root sheaths, seems to be peaked by nature on the periphery. The results are discussed against the background of the range of values of concentrations of certain elements found in the literature.
Fungal-Induced Deterioration of Mural Paintings: In Situ and Mock-Model Microscopy Analyses.
Unković, Nikola; Grbić, Milica Ljaljević; Stupar, Miloš; Savković, Željko; Jelikić, Aleksa; Stanojević, Dragan; Vukojević, Jelena
2016-04-01
Fungal deterioration of frescoes was studied in situ on a selected Serbian church, and on a laboratory model, utilizing standard and newly implemented microscopy techniques. Scanning electron microscopy (SEM) with energy-dispersive X-ray confirmed the limestone components of the plaster. Pigments used were identified as carbon black, green earth, iron oxide, ocher, and an ocher/cinnabar mixture. In situ microscopy, applied via a portable microscope ShuttlePix P-400R, proved very useful for detection of invisible micro-impairments and hidden, symptomless, microbial growth. SEM and optical microscopy established that observed deterioration symptoms, predominantly discoloration and pulverization of painted layers, were due to bacterial filaments and fungal hyphal penetration, and formation of a wide range of fungal structures (i.e., melanized hyphae, chlamydospores, microcolonial clusters, Cladosporium-like conidia, and Chaetomium perithecia and ascospores). The all year-round monitoring of spontaneous and induced fungal colonization of a "mock painting" in controlled laboratory conditions confirmed the decisive role of humidity level (70.18±6.91% RH) in efficient colonization of painted surfaces, as well as demonstrated increased bioreceptivity of painted surfaces to fungal colonization when plant-based adhesives (ilinocopie, murdent), compared with organic adhesives of animal origin (bone glue, egg white), are used for pigment sizing.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sun, Z. J.; Wells, D.; Green, J.
Photon Activation Analysis (PAA) of environmental, archaeological and industrial samples requires extensive data analysis that is susceptible to error. For the purpose of saving time, manpower and minimizing error, a computer program was designed, built and implemented using SQL, Access 2007 and asp.net technology to automate this process. Based on the peak information of the spectrum and assisted by its PAA library, the program automatically identifies elements in the samples and calculates their concentrations and respective uncertainties. The software also could be operated in browser/server mode, which gives the possibility to use it anywhere the internet is accessible. By switchingmore » the nuclide library and the related formula behind, the new software can be easily expanded to neutron activation analysis (NAA), charged particle activation analysis (CPAA) or proton-induced X-ray emission (PIXE). Implementation of this would standardize the analysis of nuclear activation data. Results from this software were compared to standard PAA analysis with excellent agreement. With minimum input from the user, the software has proven to be fast, user-friendly and reliable.« less
mESAdb: microRNA Expression and Sequence Analysis Database
Kaya, Koray D.; Karakülah, Gökhan; Yakıcıer, Cengiz M.; Acar, Aybar C.; Konu, Özlen
2011-01-01
microRNA expression and sequence analysis database (http://konulab.fen.bilkent.edu.tr/mirna/) (mESAdb) is a regularly updated database for the multivariate analysis of sequences and expression of microRNAs from multiple taxa. mESAdb is modular and has a user interface implemented in PHP and JavaScript and coupled with statistical analysis and visualization packages written for the R language. The database primarily comprises mature microRNA sequences and their target data, along with selected human, mouse and zebrafish expression data sets. mESAdb analysis modules allow (i) mining of microRNA expression data sets for subsets of microRNAs selected manually or by motif; (ii) pair-wise multivariate analysis of expression data sets within and between taxa; and (iii) association of microRNA subsets with annotation databases, HUGE Navigator, KEGG and GO. The use of existing and customized R packages facilitates future addition of data sets and analysis tools. Furthermore, the ability to upload and analyze user-specified data sets makes mESAdb an interactive and expandable analysis tool for microRNA sequence and expression data. PMID:21177657
mESAdb: microRNA expression and sequence analysis database.
Kaya, Koray D; Karakülah, Gökhan; Yakicier, Cengiz M; Acar, Aybar C; Konu, Ozlen
2011-01-01
microRNA expression and sequence analysis database (http://konulab.fen.bilkent.edu.tr/mirna/) (mESAdb) is a regularly updated database for the multivariate analysis of sequences and expression of microRNAs from multiple taxa. mESAdb is modular and has a user interface implemented in PHP and JavaScript and coupled with statistical analysis and visualization packages written for the R language. The database primarily comprises mature microRNA sequences and their target data, along with selected human, mouse and zebrafish expression data sets. mESAdb analysis modules allow (i) mining of microRNA expression data sets for subsets of microRNAs selected manually or by motif; (ii) pair-wise multivariate analysis of expression data sets within and between taxa; and (iii) association of microRNA subsets with annotation databases, HUGE Navigator, KEGG and GO. The use of existing and customized R packages facilitates future addition of data sets and analysis tools. Furthermore, the ability to upload and analyze user-specified data sets makes mESAdb an interactive and expandable analysis tool for microRNA sequence and expression data.
NASA Astrophysics Data System (ADS)
Rout, Bibhudutta; Dhoubhadel, Mangal S.; Poudel, Prakash R.; Kummari, Venkata C.; Pandey, Bimal; Deoli, Naresh T.; Lakshantha, Wickramaarachchige J.; Mulware, Stephen J.; Baxley, Jacob; Manuel, Jack E.; Pacheco, Jose L.; Szilasi, Szabolcs; Weathers, Duncan L.; Reinert, Tilo; Glass, Gary A.; Duggan, Jerry L.; McDaniel, Floyd D.
2013-07-01
The Ion Beam Modification and Analysis Laboratory (IBMAL) at the University of North Texas includes several accelerator facilities with capabilities of producing a variety of ion beams from tens of keV to several MeV in energy. The four accelerators are used for research, graduate and undergraduate education, and industrial applications. The NEC 3MV Pelletron tandem accelerator has three ion sources for negative ions: He Alphatross and two different SNICS-type sputter ion sources. Presently, the tandem accelerator has four high-energy beam transport lines and one low-energy beam transport line directly taken from the negative ion sources for different research experiments. For the low-energy beam line, the ion energy can be varied from ˜20 to 80 keV for ion implantation/modification of materials. The four post-acceleration beam lines include a heavy-ion nuclear microprobe; multi-purpose PIXE, RBS, ERD, NRA, and broad-beam single-event upset; high-energy ion implantation line; and trace-element accelerator mass spectrometry. The NEC 3MV single-ended Pelletron accelerator has an RF ion source mainly for hydrogen, helium and heavier inert gases. We recently installed a capacitive liner to the terminal potential stabilization system for high terminal voltage stability and high-resolution microprobe analysis. The accelerator serves a beam line for standard RBS and RBS/C. Another beamline for high energy focused ion beam application using a magnetic quadrupole lens system is currently under construction. This beam line will also serve for developmental work on an electrostatic lens system. The third accelerator is a 200 kV Cockcroft-Walton accelerator with an RF ion source. The fourth accelerator is a 2.5 MV Van de Graaff accelerator, which was in operation for last several decades is currently planned to be used mainly for educational purpose. Research projects that will be briefly discussed include materials synthesis/modification for photonic, electronic, and magnetic applications, surface sputtering and micro-fabrication of materials, development of high-energy ion microprobe systems, and educational and outreach activities.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rout, Bibhudutta; Dhoubhadel, Mangal S.; Poudel, Prakash R.
2013-07-03
The Ion Beam Modification and Analysis Laboratory (IBMAL) at the University of North Texas includes several accelerator facilities with capabilities of producing a variety of ion beams from tens of keV to several MeV in energy. The four accelerators are used for research, graduate and undergraduate education, and industrial applications. The NEC 3MV Pelletron tandem accelerator has three ion sources for negative ions: He Alphatross and two different SNICS-type sputter ion sources. Presently, the tandem accelerator has four high-energy beam transport lines and one low-energy beam transport line directly taken from the negative ion sources for different research experiments. Formore » the low-energy beam line, the ion energy can be varied from {approx}20 to 80 keV for ion implantation/modification of materials. The four post-acceleration beam lines include a heavy-ion nuclear microprobe; multi-purpose PIXE, RBS, ERD, NRA, and broad-beam single-event upset; high-energy ion implantation line; and trace-element accelerator mass spectrometry. The NEC 3MV single-ended Pelletron accelerator has an RF ion source mainly for hydrogen, helium and heavier inert gases. We recently installed a capacitive liner to the terminal potential stabilization system for high terminal voltage stability and high-resolution microprobe analysis. The accelerator serves a beam line for standard RBS and RBS/C. Another beamline for high energy focused ion beam application using a magnetic quadrupole lens system is currently under construction. This beam line will also serve for developmental work on an electrostatic lens system. The third accelerator is a 200 kV Cockcroft-Walton accelerator with an RF ion source. The fourth accelerator is a 2.5 MV Van de Graaff accelerator, which was in operation for last several decades is currently planned to be used mainly for educational purpose. Research projects that will be briefly discussed include materials synthesis/modification for photonic, electronic, and magnetic applications, surface sputtering and micro-fabrication of materials, development of high-energy ion microprobe systems, and educational and outreach activities.« less
Study of the atmospheric aerosol composition in equatorial Africa using PIXE as analytical technique
NASA Astrophysics Data System (ADS)
Maenhaut, W.; Akilimali, K.
1987-03-01
Small Nuclepore total filter holders and a single orifice 8-stage cascade impactor were used to collect atmospheric aerosol samples in Kinshasa, Zaire, and Butare, Rwanda. The samples were analyzed for about 20 elements by means of the PIXE technique. The results obtained for parallel samples, taken with two total filter holders and one cascade impactor, were generally in excellent agreement, suggesting that the different samplers collected very similar aerosol particle populations. Most elements were associated with a crustal dust dispersion source, which may include road dust dispersal. The Butare samples, particularly those collected during the night, were significantly influenced by biomass burning, as was deduced from enhanced filter blackness and noncrustal K levels. The pyrogenic component also contained P, S, Mn and Rb. Br and Pb were highly enriched at both locations, indicating that automotive sources had a strong influence on the aerosol composition.
An ion accelerator for undergraduate research and teaching
NASA Astrophysics Data System (ADS)
Monce, Michael
1997-04-01
We have recently upgraded our 400kV, single beam line ion accelerator to a 1MV, multiple beam line machine. This upgrade has greatly expanded the opportunities for student involvement in the laboratory. We will describe four areas of work in which students now participate. The first is the continuing research being conducted in excitations produced in ion-molecule collisions, which recently involved the use of digital imaging. The second area of research now opened up by the new accelerator involves PIXE. We are currently beginning a cross disciplinary study of archaeological specimens using PIXE and involving students from both anthropology and physics. Finally, two beam lines from the accelerator will be used for basic work in nuclear physics: Rutherford scattering and nuclear resonances. These two nuclear physics experiments will be integrated into our sophomore-junior level, year-long course in experimental physics.
Application of PIXE to the study of Renaissance style enamelled gold jewelry
NASA Astrophysics Data System (ADS)
Weldon, M.; Carlson, J.; Reedy, S.; Swann, C. P.
1996-04-01
This study examines and compares three pieces of Renaissance style gold and enamelled jewelry owned by the Walters Art Gallery, Baltimore, MD, USA. These are a 16th century Hat Badge of Adam and Eve, a 19th century Fortitude Pendant and a Diana Pendant presumed to be of the 16th century (The Walters Art Gallery, Jewelry, Ancient to Modern (Viking, New York, 1979)), Ref. [1]. PIXE spectroscopy was applied to examine the elemental composition of the gold and of the enamels. Compositional differences, including the use of post-Renaissance colorants, were found between the enamels in separate regions of each of the three pieces. The modern colorant, chromium, was, in fact, found in all of the pieces and uranium was found in only the Diana Pendant. There are some differences in the gold purity of the three objects; there are significant differences in the solders used even within one object, the Fortitude Pendant.
VIMOS - a Cosmology Machine for the VLT
NASA Astrophysics Data System (ADS)
2002-03-01
Successful Test Observations With Powerful New Instrument at Paranal [1] Summary One of the most fundamental tasks of modern astrophysics is the study of the evolution of the Universe . This is a daunting undertaking that requires extensive observations of large samples of objects in order to produce reasonably detailed maps of the distribution of galaxies in the Universe and to perform statistical analysis. Much effort is now being put into mapping the relatively nearby space and thereby to learn how the Universe looks today . But to study its evolution, we must compare this with how it looked when it still was young . This is possible, because astronomers can "look back in time" by studying remote objects - the larger their distance, the longer the light we now observe has been underway to us, and the longer is thus the corresponding "look-back time". This may sound easy, but it is not. Very distant objects are very dim and can only be observed with large telescopes. Looking at one object at a time would make such a study extremely time-consuming and, in practical terms, impossible. To do it anyhow, we need the largest possible telescope with a highly specialised, exceedingly sensitive instrument that is able to observe a very large number of (faint) objects in the remote universe simultaneously . The VLT VIsible Multi-Object Spectrograph (VIMOS) is such an instrument. It can obtain many hundreds of spectra of individual galaxies in the shortest possible time; in fact, in one special observing mode, up to 6400 spectra of the galaxies in a remote cluster during a single exposure, augmenting the data gathering power of the telescope by the same proportion. This marvellous science machine has just been installed at the 8.2-m MELIPAL telescope, the third unit of the Very Large Telescope (VLT) at the ESO Paranal Observatory. A main task will be to carry out 3-dimensional mapping of the distant Universe from which we can learn its large-scale structure . "First light" was achieved on February 26, 2002, and a first series of test observations has successfully demonstrated the huge potential of this amazing facility. Much work on VIMOS is still ahead during the coming months in order to put into full operation and fine-tune the most efficient "galaxy cruncher" in the world. VIMOS is the outcome of a fruitful collaboration between ESO and several research institutes in France and Italy, under the responsibility of the Laboratoire d'Astrophysique de Marseille (CNRS, France). The other partners in the "VIRMOS Consortium" are the Laboratoire d'Astrophysique de Toulouse, Observatoire Midi-Pyrénées, and Observatoire de Haute-Provence in France, and Istituto di Radioastronomia (Bologna), Istituto di Fisica Cosmica e Tecnologie Relative (Milano), Osservatorio Astronomico di Bologna, Osservatorio Astronomico di Brera (Milano) and Osservatorio Astronomico di Capodimonte (Naples) in Italy. PR Photo 09a/02 : VIMOS image of the Antennae Galaxies (centre). PR Photo 09b/02 : First VIMOS Multi-Object Spectrum (full field) PR Photo 09c/02 : The VIMOS instrument on VLT MELIPAL PR Photo 09d/02 : The VIMOS team at "First Light". PR Photo 09e/02 : "First Light" image of NGC 5364 PR Photo 09f/02 : Image of the Crab Nebula PR Photo 09g/02 : Image of spiral galaxy NGC 2613 PR Photo 09h/02 : Image of spiral galaxy Messier 100 PR Photo 09i/02 : Image of cluster of galaxies ACO 3341 PR Photo 09j/02 : Image of cluster of galaxies MS 1008.1-1224 PR Photo 09k/02 : Mask design for MOS exposure PR Photo 09l/02 : First VIMOS Multi-Object Spectrum (detail) PR Photo 09m/02 : Integrated Field Spectroscopy of central area of the "Antennae Galaxies" PR Photo 09n/02 : Integrated Field Spectroscopy of central area of the "Antennae Galaxies" (detail) Science with VIMOS ESO PR Photo 09a/02 ESO PR Photo 09a/02 [Preview - JPEG: 400 x 469 pix - 152k] [Normal - JPEG: 800 x 938 pix - 408k] ESO PR Photo 09b/02 ESO PR Photo 09b/02 [Preview - JPEG: 400 x 511 pix - 304k] [Normal - JPEG: 800 x 1022 pix - 728k] Caption : PR Photo 09a/02 : One of the first images from the new VIMOS facility, obtained right after the moment of "first light" on Ferbruary 26, 2002. It shows the famous "Antennae Galaxies" (NGC 4038/39), the result of a recent collision between two galaxies. As an immediate outcome of this dramatic event, stars are born within massive complexes that appear blue in this composite photo, based on exposures through green, orange and red optical filtres. PR Photo 09b/02 : Some of the first spectra of distant galaxies obtained with VIMOS in Multi-Object-Spectroscopy (MOS) mode. More than 220 galaxies were observed simultaneously, an unprecedented efficiency for such a "deep" exposure, reaching so far out in space. These spectra allow to obtain the redshift, a measure of distance, as well as to assess the physical status of the gas and stars in each of these galaxies. A part of this photo is enlarged as PR Photo 09l/02. Technical information about these photos is available below. Other "First Light" images from VIMOS are shown in the photo gallery below. The next in the long series of front-line instruments to be installed on the ESO Very Large Telescope (VLT), VIMOS (and its complementary, infrared-sensitive counterpart NIRMOS, now in the design stage) will allow mapping of the distribution of galaxies, clusters, and quasars during a time interval spanning more than 90% of the age of the universe. It will let us look back in time to a moment only ~1.5 billion years after the Big Bang (corresponding to a redshift of about 5). Like archaeologists, astronomers can then dig deep into those early ages when the first building blocks of galaxies were still in the process of formation. They will be able to determine when most of the star formation occurred in the universe and how it evolved with time. They will analyse how the galaxies cluster in space, and how this distribution varies with time. Such observations will put important constraints on evolution models, in particular on the average density of matter in the Universe. Mapping the distant universe requires to determine the distances of the enormous numbers of remote galaxies seen in deep pictures of the sky, adding depth - the third, indispensible dimension - to the photo. VIMOS offers this capability, and very efficiently. Multi-object spectroscopy is a technique by which many objects are observed simultaneously. VIMOS can observe the spectra of about 1000 galaxies in one exposure, from which redshifts, hence distances, can be measured [2]. The possibility to observe two galaxies at once would be equivalent to having a telescope twice the size of a VLT Unit Telescope. VIMOS thus effectively "increases" the size of the VLT hundreds of times. From these spectra, the stellar and gaseous content and internal velocities of galaxies can be infered, forming the base for detailed physical studies. At present the distances of only a few thousand galaxies and quasars have been measured in the distant universe. VIMOS aims at observing 100 times more, over one hundred thousand of those remote objects. This will form a solid base for unprecedented and detailed statistical studies of the population of galaxies and quasars in the very early universe. The international VIRMOS Consortium VIMOS is one of two major astronomical instruments to be delivered by the VIRMOS Consortium of French and Italian institutes under a contract signed in the summer of 1997 between the European Southern Observatory (ESO) and the French Centre National de la Recherche Scientifique (CNRS). The participating institutes are: in France: * Laboratoire d'Astrophysique de Marseille (LAM), Observatoire Marseille-Provence (project responsible) * Laboratoire d'Astrophysique de Toulouse, Observatoire Midi-Pyrénées * Observatoire de Haute-Provence (OHP) in Italy: * Istituto di Radioastronomia (IRA-CNR) (Bologna) * Istituto di Fisica Cosmica e Tecnologie Relative (IFCTR) (Milano) * Osservatorio Astronomico di Capodimonte (OAC) (Naples) * Osservatorio Astronomico di Bologna (OABo) * Osservatorio Astronomico di Brera (OABr) (Milano) VIMOS at the VLT: a unique and powerful combination ESO PR Photo 09c/02 ESO PR Photo 09c/02 [Preview - JPEG: 501 x 400 pix - 312k] [Normal - JPEG: 1002 x 800 pix - 840k] Caption : PR Photo 09c/02 shows the new VIMOS instrument on one of the Nasmyth platforms of the 8.2-m VLT MELIPAL telescope at Paranal. VIMOS is installed on the Nasmyth "Focus B" platform of the 8.2-m VLT MELIPAL telescope, cf. PR Photo 09c/02 . It may be compared to four multi-mode instruments of the FORS-type (cf. ESO PR 14/98 ), joined in one stiff structure. The construction of VIMOS has involved the production of large and complex optical elements and their integration in more than 30 remotely controlled, finely moving functions in the instrument. In the configuration employed for the "first light", VIMOS made use of two of its four channels. The two others will be put into operation in the next commissioning period during the coming months. However, VIMOS is already now the most efficient multi-object spectrograph in the world , with an equivalent (accumulated) slit length of up to 70 arcmin on the sky. VIMOS has a field-of-view as large as half of the full moon (14 x 16 arcmin 2 for the four quadrants), the largest sky field to be imaged so far by the VLT. It has excellent sensitivity in the blue region of the spectrum (about 60% more efficient than any other similar instruments in the ultraviolet band), and it is also very sensitive in all other visible spectral regions, all the way to the red limit. But the absolutely unique feature of VIMOS is its capability to take large numbers of spectra simultaneously , leading to exceedingly efficient use of the observing time. Up to about 1000 objects can be observed in a single exposure in multi-slit mode. And no less than 6400 spectra can be recorded with the Integral Field Unit , in which a closely packed fibre optics bundle can simultaneously observe a continuous sky area measuring no less than 56 x 56 arcsec 2. A dedicated machine, the Mask Manufacturing Unit (MMU) , cuts the slits for the entrance apertures of the spectrograph. The laser is capable of cutting 200 slits in less than 15 minutes. This facility was put into operation at Paranal by the VIRMOS Consortium already in August 2000 and has since been extensively used for observations with the FORS2 instrument; more details are available in ESO PR 19/99. Fast start-up of VIMOS at Paranal ESO PR Photo 09d/02 ESO PR Photo 09d/02 [Preview - JPEG: 473 x 400 pix - 280k] [Normal - JPEG: 946 x 1209 pix - 728k] ESO PR Photo 09e/02 ESO PR Photo 09e/02 [Preview - JPEG: 400 x 438 pix - 176k] [Normal - JPEG: 800 x 876 pix - 664k] Caption : PR Photo 09d/02 : The VIRMOS team in the MELIPAL control room, moments after "First Light" on February 26, 2002. From left to right: Oreste Caputi, Marco Scodeggio, Giovanni Sciarretta , Olivier Le Fevre, Sylvie Brau-Nogue, Christian Lucuix, Bianca Garilli, Markus Kissler-Patig (in front), Xavier Reyes, Michel Saisse, Luc Arnold and Guido Mancini . PR Photo 09e/02 : The spiral galaxy NGC 5364 was the first object to be observed by VIMOS. This false-colour near-infrared, raw "First Light" photo shows the extensive spiral arms. Technical information about this photo is available below. VIMOS was shipped from Observatoire de Haute-Provence (France) at the end of 2001, and reassembled at Paranal during a first period in January 2002. From mid-February, the instrument was made ready for installation on the VLT MELIPAL telescope; this happened on February 24, 2002. VIMOS saw "First Light" just two days later, on February 26, 2000, cf. PR Photo 09e/02 . During the same night, a number of excellent images were obtained of various objects, demonstrating the fine capabilities of the instrument in the "direct imaging"-mode. The first spectra were successfully taken during the night of March 2 - 3, 2002 . The slit masks that were used on this occasion were prepared with dedicated software that also optimizes the object selection, cf. PR Photo 09k/02 , and were then cut with the laser machine. From the first try on, the masks have been well aligned on the sky objects. The first observations with large numbers of spectra were obtained shortly thereafter. First accomplishments Images of nearby galaxies, clusters of galaxies, and distant galaxy fields were among the first to be obtained, using the VIMOS imaging mode and demonstrating the excellent efficiency of the instrument, various examples are shown below. The first observations of multi-spectra were performed in a selected sky field in which many faint galaxies are present; it is known as the "VIRMOS-VLT Deep Survey Field at 1000+02". Thanks to the excellent sensitivity of VIMOS, the spectra of galaxies as faint as (red) magnitude R = 23 (i.e. over 6 million times fainter than what can be perceived with the unaided eye) are visible on exposures lasting only 15 minutes. Some of the first observations with the Integral Field Unit were made of the core of the famous Antennae Galaxies (NGC 4038/39) . They will form the basis for a detailed map of the strong emission produced by the current, dramatic collision of the two galaxies. First Images and Spectra from VIMOS - a Gallery The following photos are from a collection of the first images and spectra obtained with VIMOS . See also PR Photos 09a/02 , 09b/02 and 09e/02 , reproduced above. Technical information about all of them is available below. ESO PR Photo 09f/02 ESO PR Photo 09f/02 [Preview - JPEG: 400 x 469 pix - 224k] [Normal - JPEG: 800 x 937 pix - 544k] [HiRes - JPEG: 2001 x 2343 pix - 3.6M] Caption : PR Photo 09f/02 : The Crab Nebula (Messier 1) , as observed by VIMOS. This well-known object is the remnant of a stellar explosion in the year 1054. ESO PR Photo 09g/02 ESO PR Photo 09g/02 [Preview - JPEG: 478 x 400 pix - 184k] [Normal - JPEG: 956 x 1209 pix - 416k] [HiRes - JPEG: 1801 x 1507 pix - 1.4M] Caption : PR Photo 09g/02 : VIMOS photo of NGC 2613 , a spiral galaxy that ressembles our own Milky Way. ESO PR Photo 09h/02 ESO PR Photo 09h/02 [Preview - JPEG: 400 x 469 pix - 152k] [Normal - JPEG: 800 x 938 pix - 440k] [HiRes - JPEG: 1800 x 2100 pix - 2.0M] Caption : PR Photo 09h/02 : Messier 100 is one of the largest and brightest spiral galaxies in the sky. ESO PR Photo 09i/02 ESO PR Photo 09i/02 [Preview - JPEG: 400 x 405 pix - 144k] [Normal - JPEG: 800 x 810 pix - 312k] Caption : PR Photo 09i/02 : The cluster of galaxies ACO 3341 is located at a distance of about 300 million light-years (redshift z = 0.037), i.e., comparatively nearby in cosmological terms. It contains a large number of galaxies of different size and brightness that are bound together by gravity. ESO PR Photo 09j/02 ESO PR Photo 09j/02 [Preview - JPEG: 447 x 400 pix - 200k] [Normal - JPEG: 893 x 800 pix - 472k] [HiRes - JPEG: 1562 x 1399 pix - 1.1M] Caption : PR Photo 09j/02 : The distant cluster of galaxies MS 1008.1-1224 is some 3 billion light-years distant (redshift z = 0.301). The galaxies in this cluster - that we observe as they were 3 billion years ago - are different from galaxies in our neighborhood; their stellar populations, on the average, are younger. ESO PR Photo 09k/02 ESO PR Photo 09k/02 [Preview - JPEG: 400 x 455 pix - 280k] [Normal - JPEG: 800 x 909 pix - 696k] Caption : PR Photo 09k/02 : Design of a Mask for Multi-Object Spectroscopy (MOS) observations with VIMOS. The mask serves to block, as far as possible, unwanted background light from the "night sky" (radiation from atoms and molecules in the Earth's upper atmosphere). During the set-up process for multi-object observations, the VIMOS software optimizes the position of the individual slits in the mask (one for each object for which a spectrum will be obtained) before these are cut. The photo shows an example of this fitting process, with the slit contours superposed on a short pre-exposure of the sky field to be observed. ESO PR Photo 09l/02 ESO PR Photo 09l/02 [Preview - JPEG: 470 x 400 pix - 200k] [Normal - JPEG: 939 x 800 pix - 464k] Caption : PR Photo 09l/02 : First Multi-Object Spectroscopy (MOS) observations with VIMOS; enlargement of a small part of the field shown in PR Photo 09b/02. The light from each galaxy passes through the dedicated slit in the mask (see PR Photo 09k/02 ) and produces a spectrum on the detector. Each vertical rectangle contains the spectrum of one galaxy that is located several billion light-years away. The horizontal lines are the strong emission from the "night sky" (radiation from atoms and molecules in the Earth's upper atmosphere), while the vertical traces are the spectral signatures of the galaxies. The full field contains the spectra of over 220 galaxies that were observed simultaneously, illustrating the great efficiency of this technique. Later, about 1000 spectra will be obtained in one exposure. ESO PR Photo 09m/02 ESO PR Photo 09m/02 [Preview - JPEG: 470 x 400 pix - 264k] [Normal - JPEG: 939 x 800 pix - 720k] Caption : PR Photo 09m/02 : was obtained with the Integral Field Spectroscopy mode of VIMOS. In one single exposure, more than 3000 spectra were taken of the central area of the Antennae Galaxies ( PR Photo 09a/02 ). ESO PR Photo 09n/02 ESO PR Photo 09n/02 [Preview - JPEG: 532 x 400 pix - 320k] [Normal - JPEG: 1063 x 800 pix - 864k] Caption : PR Photo 09n/02 : An enlargement of a small area in PR Photo 09m/02. This observation allows mapping of the distribution of elements like hydrogen (H) and sulphur (S II), for which the signatures are clearly identified in these spectra. The wavelength increases towards the top (arrow). Notes [1]: This is a joint Press Release of ESO , Centre National de la Recherche Scientifique (CNRS) in France, and Consiglio Nazionale delle Ricerche (CNR) and Istituto Nazionale di Astrofisica (INAF) in Italy. [2]: In astronomy, the redshift denotes the fraction by which the lines in the spectrum of an object are shifted towards longer wavelengths. The observed redshift of a distant galaxy gives a direct estimate of the apparent recession velocity as caused by the universal expansion. Since the expansion rate increases with distance, the velocity is itself a function (the Hubble relation) of the distance to the object. Technical information about the photos PR Photo 09a/01 : Composite VRI image of NGC 4038/39, obtained on 26 February 2002, in a bright sky (full moon). Individual exposures of 60 sec each; image quality 0.6 arcsec FWHM; the field measures 3.5 x 3.5 arcmin 2. North is up and East is left. PR Photo 09b/02 : MOS-spectra obtained with two quadrants totalling 221 slits + 6 reference objects (stars placed in square holes to ensure a correct alignment). Exposure time 15 min; LR(red) grism. This is the raw (unprocessed) image of the spectra. PR Photo 09e/02 : A 60 sec i exposure of NGC 5364 on February 26, 2002; image quality 0.6 arcsec FWHM; full moon; 3.5 x 3.5 arcmin 2 ; North is up and East is left. PR Photo 09f/02 : Composite VRI image of Messier 1, obtained on March 4, 2002. The individual exposures lasted 180 sec; image quality 0.7 arcsec FWHM; field 7 x 7 arcmin 2 ; North is up and East is left. PR Photo 09g/02 : Composite VRI image of NGC 2613, obtained on February 28, 2002. The individual exposures lasted 180 sec; image quality 0.7 arcsec FWHM; field 7 x 7 arcmin 2 ; North is up and East is left. PR Photo 09h/02 : Composite VRI image of Messier 100, obtained on March 3, 2002. The individual exposures lasted 180 sec, image quality 0.7 arcsec FWHM; field 7 x 7 arcmin 2 ; North is up and East is left. PR Photo 09i/02 : R-band image of galaxy cluster ACO 3341, obtained on March 4, 2002. Exposure 300 sec, image quality 0.5 arcsec FWHM;. field 7 x 7 arcmin 2 ; North is up and East is left. PR Photo 09j/02 : Composite VRI image of the distant cluster of galaxies MS 1008.1-1224. The individual exposures lasted 300 sec; image quality 0.8 arcsec FWHM; field 5 x 3 arcmin 2 ; North is to the right and East is up. PR Photo 09k/02 : Mask design made with the VMMPS tool, overlaying a pre-image. The selected objects are seen at the centre of the yellow squares, where a 1 arcsec slit is cut along the spatial X-axis. The rectangles in white represent the dispersion in wavelength of the spectra along the Y-axis. Masks are cut with the Mask Manufacturing Unit (MMU) built by the Virmos Consortium. PR Photo 09l/02 : Enlargement of a small area of PR Photo 09b/02. PR Photo 09m/02 : Spectra of the central area of NGC 4038/39, obtained with the Integral Field Unit on February 26, 2002. The exposure lasted 5 min and was made with the low resolution red grating. PR Photo 09m/02 : Zoom-in on small area of PR Photo 09m/02. The strong emission lines of hydrogen (H-alpha) and ionized sulphur (S II) are seen.
Nuclear analytical techniques in medicine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cesareo, R.
1988-01-01
This book acquaints one with the fundamental principles and the instrumentation relevant to analytical technique based on atomic and nuclear physics, as well as present and future biomedical applications. Besides providing a theoretical description of the physical phenomena, a large part of the book is devoted to applications in the medical and biological field, particularly in hematology, forensic medicine and environmental science. This volume reviews methods such as the possibility of carrying out rapid multi-element analysis of trace elements on biomedical samples, in vitro and in vivo, by XRF-analysis; the ability of the PIXE-microprobe to analyze in detail and tomore » map trace elements in fragments of biomedical samples or inside the cells; the potentiality of in vivo nuclear activation analysis for diagnostic purposes. Finally, techniques are described such as radiation scattering (elastic and inelastic scattering) and attenuation measurements which will undoubtedly see great development in the immediate future.« less
NASA Astrophysics Data System (ADS)
Papadopoulou, D. N.; Zachariadis, G. A.; Anthemidis, A. N.; Tsirliganis, N. C.; Stratis, J. A.
2004-12-01
Two multielement instrumental methods of analysis, micro X-ray fluorescence spectrometry (micro-XRF) and inductively coupled plasma atomic emission spectrometry (ICP-AES) were applied for the analysis of 7th and 5th century B.C. ancient ceramic sherds in order to evaluate the above two methods and to assess the potential to use the current compact and portable micro-XRF instrument for the in situ analysis of ancient ceramics. The distinguishing factor of interest is that micro-XRF spectrometry offers the possibility of a nondestructive analysis, an aspect of primary importance in the compositional analysis of cultural objects. Micro-XRF measurements were performed firstly directly on the ceramic sherds with no special pretreatment apart from surface cleaning (micro-XRF on sherds) and secondly on pressed pellet disks which were prepared for each ceramic sherd (micro-XRF on pellet). For the ICP-AES determination of elements, test solutions were prepared by the application of a microwave-assisted decomposition procedure in closed high-pressure PFA vessels. Also, the standard reference material SARM 69 was used for the efficiency calibration of the micro-XRF instrument and was analysed by both methods. In order to verify the calibration, the standard reference materials NCS DC 73332 and SRM620 as well as the reference materials AWI-1 and PRI-1 were analysed by micro-XRF. Elemental concentrations determined by the three analytical procedures (ICP-AES, micro-XRF on sherds and micro-XRF on pellets) were statistically treated by correlation analysis and Student's t-test (at the 95% confidence level).
The Case of Carpathian (Transylvanian) Gold and its Use for Archaeological Items
NASA Astrophysics Data System (ADS)
Stan, D.; Constantinescu, B.; Vasilescu, A.; Radtke, M.; Reinholz, U.; Pop, D.; Ionescu, C.
2009-04-01
Romania was one of Europe's main gold-producing areas since the antiquity, especially through the ore deposits in the "Golden Quadrilateral" of the Western Carpathians. The Babeş-Bolyai University in Cluj-Napoca hosts a gold collection consisting of about 500 samples, most of them from Roşia Montană. The geochemical investigation of Romanian gold by using SR-XRF and micro-PIXE is currently in progress; some preliminary results point to interesting features. The goal of the study is to verify if Transylvanian gold was used to manufacture Romanian archaeological objects. This is realized by using information related to trace elements: Sb, Te, Pb - recognized fingerprints for Carpathian Mountains mines and Sn characteristic for the panned river-bed (alluvional) gold. To solve these issues, samples (grains, nuggets, fine gold "sand") from various Transylvanian mines and rivers and some very small (few milligrams) fragments of archaeological objects are measured. Another outcome of this SR-XRF experiment is to obtain the elemental characterization (Au, Ag and Cu) of representative gold mines, subject of interest for the assignement of any other archaeological artifacts to one of the Central European gold sources. During the experiment, point spectra for 22 natural gold samples and 18 "micronic" samples from archaeological objects were acquired at 34 keV excitation SR energy, using a spatially resolved SR-XRF set-up mounted for analyses at the hard X-ray beam line - BAMline at BESSY, Berlin. A summary for the characterization of Transylvanian native gold is the following: high (8 - 30%) Ag amounts and low (0.2 - 1%) Cu amounts; placer deposits contain as fingerprint Sn (150-300 ppm) - most probably from river bed cassiterite; primary deposits present as fingerprints Te (200-2000 ppm), Sb (150-300 ppm) - however, the samples are very inhomogeneous. The micro-PIXE experiment was performed at the AN 2000 Van de Graaff accelerator of Laboratori Nazionali di Legnaro. Elemental maps of gold samples were obtained, complemented by nuclear microprobe point analyses in selected areas of the mapped gold crystals. At Roşia Montană, the mapping evidenced a peculiar microfabric consisting of mm-sized laths of a Zn-S rich phase (with minor Cu and Fe). Au content shows a wide compositional range: 36-57%. A clear chemical inhomogeneity of the Au/Ag ratio, as well as of the local concentration of other elements (Cu, As, Sb, Te, Pb, Fe) was noticed at submilimeter scale. The presence of associated mineral phases (such as Cu, Ag, chalcopyrite, galena, sphalerite, arsenopyrite, pyrite/marcasite and non-metallic minerals) at microscopic scale could be thus illustrated. As concerning the archaeological samples, for "koson" dacian coins, the type "with monogram" is made from refined (more than 97%) gold with no Sb, Te or Sn traces (remelted gold) and the type "without monogram" is clearly made from alluvial gold, partially combined with primary Transylvanian gold (Sn and Sb traces detected). The greek "pseudolysimachus" type staters (contemporary with "kosons") are made from refined remelted gold (no Sn, Sb, Te presence).
Buckling analysis of planar compression micro-springs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Jing; Sui, Li; Shi, Gengchen
2015-04-15
Large compression deformation causes micro-springs buckling and loss of load capacity. We analyzed the impact of structural parameters and boundary conditions for planar micro-springs, and obtained the change rules for the two factors that affect buckling. A formula for critical buckling deformation of micro-springs under compressive load was derived based on elastic thin plate theory. Results from this formula were compared with finite element analysis results but these did not always correlate. Therefore, finite element analysis is necessary for micro-spring buckling analysis. We studied the variation of micro-spring critical buckling deformation caused by four structural parameters using ANSYS software undermore » two constraint conditions. The simulation results show that when an x-direction constraint is added, the critical buckling deformation increases by 32.3-297.9%. The critical buckling deformation decreases with increase in micro-spring arc radius or section width and increases with increase in micro-spring thickness or straight beam width. We conducted experiments to confirm the simulation results, and the experimental and simulation trends were found to agree. Buckling analysis of the micro-spring establishes a theoretical foundation for optimizing micro-spring structural parameters and constraint conditions to maximize the critical buckling load.« less
Computational Characterization of Exogenous MicroRNAs that Can Be Transferred into Human Circulation
Shu, Jiang; Chiang, Kevin; Zempleni, Janos; Cui, Juan
2015-01-01
MicroRNAs have been long considered synthesized endogenously until very recent discoveries showing that human can absorb dietary microRNAs from animal and plant origins while the mechanism remains unknown. Compelling evidences of microRNAs from rice, milk, and honeysuckle transported to human blood and tissues have created a high volume of interests in the fundamental questions that which and how exogenous microRNAs can be transferred into human circulation and possibly exert functions in humans. Here we present an integrated genomics and computational analysis to study the potential deciding features of transportable microRNAs. Specifically, we analyzed all publicly available microRNAs, a total of 34,612 from 194 species, with 1,102 features derived from the microRNA sequence and structure. Through in-depth bioinformatics analysis, 8 groups of discriminative features have been used to characterize human circulating microRNAs and infer the likelihood that a microRNA will get transferred into human circulation. For example, 345 dietary microRNAs have been predicted as highly transportable candidates where 117 of them have identical sequences with their homologs in human and 73 are known to be associated with exosomes. Through a milk feeding experiment, we have validated 9 cow-milk microRNAs in human plasma using microRNA-sequencing analysis, including the top ranked microRNAs such as bta-miR-487b, miR-181b, and miR-421. The implications in health-related processes have been illustrated in the functional analysis. This work demonstrates the data-driven computational analysis is highly promising to study novel molecular characteristics of transportable microRNAs while bypassing the complex mechanistic details. PMID:26528912
Shu, Jiang; Chiang, Kevin; Zempleni, Janos; Cui, Juan
2015-01-01
MicroRNAs have been long considered synthesized endogenously until very recent discoveries showing that human can absorb dietary microRNAs from animal and plant origins while the mechanism remains unknown. Compelling evidences of microRNAs from rice, milk, and honeysuckle transported to human blood and tissues have created a high volume of interests in the fundamental questions that which and how exogenous microRNAs can be transferred into human circulation and possibly exert functions in humans. Here we present an integrated genomics and computational analysis to study the potential deciding features of transportable microRNAs. Specifically, we analyzed all publicly available microRNAs, a total of 34,612 from 194 species, with 1,102 features derived from the microRNA sequence and structure. Through in-depth bioinformatics analysis, 8 groups of discriminative features have been used to characterize human circulating microRNAs and infer the likelihood that a microRNA will get transferred into human circulation. For example, 345 dietary microRNAs have been predicted as highly transportable candidates where 117 of them have identical sequences with their homologs in human and 73 are known to be associated with exosomes. Through a milk feeding experiment, we have validated 9 cow-milk microRNAs in human plasma using microRNA-sequencing analysis, including the top ranked microRNAs such as bta-miR-487b, miR-181b, and miR-421. The implications in health-related processes have been illustrated in the functional analysis. This work demonstrates the data-driven computational analysis is highly promising to study novel molecular characteristics of transportable microRNAs while bypassing the complex mechanistic details.
Nondestructive Analysis of Astromaterials by Micro-CT and Micro-XRF Analysis for PET Examination
NASA Astrophysics Data System (ADS)
Zeigler, R. A.; Righter, K.; Allen, C. C.
2013-09-01
Here we discuss our recent investigations into the applications of micro-CT and micro-XRF analyses with Apollo samples and ANSMET meteorites and assess the usefulness of these techniques in future PET.
Analyses of gold artifacts from Slovenia
NASA Astrophysics Data System (ADS)
Šmit, Ž.; Budnar, M.; Pelicon, P.; Zorko, B.; Knific, T.; Istenič, J.; Trampuž-Orel, N.; Demortier, G.
2000-03-01
The method of particle-induced X-ray emission (PIXE) was used for the study of two gold archaeological finds: a Norico-Pannonian brooch, presumably a votive item, and a pair of earrings and a ring from a Slavic female grave. The analysis was performed by an external proton millibeam and aimed to identify the manufacturing techniques. The brooch, including the spring, was made of a rather pure 98% gold. This may indicate that the brooch was produced for votive purposes, as a more flexible spring would suit an object to be worn. The Slavic ring was made of a different alloy than the earrings; moreover, its inhomogeneous alloy reveals the exploitation of local gold sources.
Standardizing Activation Analysis: New Software for Photon Activation Analysis
NASA Astrophysics Data System (ADS)
Sun, Z. J.; Wells, D.; Segebade, C.; Green, J.
2011-06-01
Photon Activation Analysis (PAA) of environmental, archaeological and industrial samples requires extensive data analysis that is susceptible to error. For the purpose of saving time, manpower and minimizing error, a computer program was designed, built and implemented using SQL, Access 2007 and asp.net technology to automate this process. Based on the peak information of the spectrum and assisted by its PAA library, the program automatically identifies elements in the samples and calculates their concentrations and respective uncertainties. The software also could be operated in browser/server mode, which gives the possibility to use it anywhere the internet is accessible. By switching the nuclide library and the related formula behind, the new software can be easily expanded to neutron activation analysis (NAA), charged particle activation analysis (CPAA) or proton-induced X-ray emission (PIXE). Implementation of this would standardize the analysis of nuclear activation data. Results from this software were compared to standard PAA analysis with excellent agreement. With minimum input from the user, the software has proven to be fast, user-friendly and reliable.
NASA Astrophysics Data System (ADS)
Trivedi, T.; Patel, Shiv P.; Chandra, P.; Bajpai, P. K.
A 3.0 MV (Pelletron 9 SDH 4, NEC, USA) low energy ion accelerator has been recently installed as the National Centre for Accelerator based Research (NCAR) at the Department of Pure & Applied Physics, Guru Ghasidas Vishwavidyalaya, Bilaspur, India. The facility is aimed to carried out interdisciplinary researches using ion beams with high current TORVIS (for H, He ions) and SNICS (for heavy ions) ion sources. The facility includes two dedicated beam lines, one for ion beam analysis (IBA) and other for ion implantation/ irradiation corresponding to switching magnet at +20 and -10 degree, respectively. Ions with 60 kV energy are injected into the accelerator tank where after stripping positively charged ions are accelerated up to 29 MeV for Au. The installed ion beam analysis techniques include RBS, PIXE, ERDA and channelling.
Main atmospheric heavy metal sources in Portugal by biomonitor analysis
NASA Astrophysics Data System (ADS)
Reis, M. A.; Alves, L. C.; Wolterbeek, H. Th.; Verburg, T.; Freitas, M. C.; Gouveia, A.
1996-04-01
During the months of July and August of 1993 a lichen collection campaign was held in Portugal where about 250 samples were collected and analysed by thick target PIXE and INAA. Results for 43 different elements were obtained and a data base was built and subjected to Monte Carlo aided target transform factor analysis (MCATTFA), method developed at IRI TU Delft. 10 × 10 km coast and 50 × 50 km far from coast sampling grids were used for collection, concentration data as well as factor patterns were extrapolated to the whole country making use of an extinction rule of 1/r 3. In this work we present the results that were obtained based on a reduced data set of 22 elements measured by TTPIXE. The results for INAA data subset and the total data set are presented elsewhere.
Applications and theory of electrokinetic enrichment in micro-nanofluidic chips.
Chen, Xueye; Zhang, Shuai; Zhang, Lei; Yao, Zhen; Chen, Xiaodong; Zheng, Yue; Liu, Yanlin
2017-09-01
This review reports the progress on the recent development of electrokinetic enrichment in micro-nanofluidic chips. The governing equations of electrokinetic enrichment in micro-nanofluidic chips are given. Various enrichment applications including protein analysis, DNA analysis, bacteria analysis, viruses analysis and cell analysis are illustrated and discussed. The advantages and difficulties of each enrichment method are expatiated. This paper will provide a particularly convenient and valuable reference to those who intend to research the electrokinetic enrichment based on micro-nanofluidic chips.
Remote identification of individual volunteer cotton plants
USDA-ARS?s Scientific Manuscript database
Although airborne multispectral remote sensing can identify fields of small cotton plants, improvements to detection sensitivity are needed to identify individual or small clusters of plants that can similarly provide habitat for boll weevils. However, when consumer-grade cameras are used, each pix...
NASA Astrophysics Data System (ADS)
Chavis, Christopher
Using commercial digital cameras in conjunction with Unmanned Aerial Systems (UAS) to generate 3-D Digital Surface Models (DSMs) and orthomosaics is emerging as a cost-effective alternative to Light Detection and Ranging (LiDAR). Powerful software applications such as Pix4D and APS can automate the generation of DSM and orthomosaic products from a handful of inputs. However, the accuracy of these models is relatively untested. The objectives of this study were to generate multiple DSM and orthomosaic pairs of the same area using Pix4D and APS from flights of imagery collected with a lightweight UAS. The accuracy of each individual DSM was assessed in addition to the consistency of the method to model one location over a period of time. Finally, this study determined if the DSMs automatically generated using lightweight UAS and commercial digital cameras could be used for detecting changes in elevation and at what scale. Accuracy was determined by comparing DSMs to a series of reference points collected with survey grade GPS. Other GPS points were also used as control points to georeference the products within Pix4D and APS. The effectiveness of the products for change detection was assessed through image differencing and observance of artificially induced, known elevation changes. The vertical accuracy with the optimal data and model is ≈ 25 cm and the highest consistency over repeat flights is a standard deviation of ≈ 5 cm. Elevation change detection based on such UAS imagery and DSM models should be viable for detecting infrastructure change in urban or suburban environments with little dense canopy vegetation.
Research on Remote Sensing recognition features of Yuan Yang Terraces in Yunnan Province (China)
NASA Astrophysics Data System (ADS)
Xiang, Jie; Chen, Jianping; Lai, ZiLi; Yang, Wei
2016-04-01
Yuan Yang terraces is one of the most famous terraces in China, and it was successfully listed in the world heritage list at the 37th world heritage convention. On the one hand, Yuan Yang terraces retain more soil and water, to reduce both hydrological connectivity and erosion, and to support irrigation. On the other hand, It has the important tourism value, bring the huge revenue to local residents. In order to protect and make use of Yuan Yang terraces better, This study analyzed the spatial distribution and spectral characteristics of terraces:(1) Through visual interpretation, the study recognized the terraces based on the spatial adjusted remote sensing image (2010 Geoeye-1 with resolution of 1m/pix), and extracted topographic feature (elevation, slope, aspect, etc.) based on the digital elevation model with resolution of 20m/pix. The terraces cover a total area of about 11.58Km2, accounted for 24.4% of the whole study area. The terraces appear at range from 1400m to 1800m in elevation, 10°to 20°in slope, northwest to northeast in aspect; (2) Using the method of weight of evidence, this study assessed the importance of different topographic feature. The results show that the sort of importance: elevation>slope>aspect; (3) The study counted the Normalized Difference Vegetation Index (NDVI) changes of terraces throughout the year, based on the landsat-5 image with resolution of 30m/pix. The results show that the changes of terraces' NDVI are bigger than other stuff (e.g. forest, road, house, etc.). Those work made a good preparations for establishing the dynamic remote sensing monitoring system of Yuan Yang terraces.
A spray technique for preparing uniform large-area PIXE calibration standards from aqueous solutions
NASA Astrophysics Data System (ADS)
Menzel, N.; Hietel, B.; Leirer, M.; Szymczak, W.; Wittmaack, K.
1999-04-01
We describe a procedure for preparing reference standards that can be used to calibrate PIXE spectra of aerosol deposits collected on suitable backing films made, for example, of synthesised polymers (polypropylene, polycarbonate etc.) or chemically modified biopolymers (e.g., cellulose actetate). Aqueous solutions of well defined concentration were prepared from metal salts. The solutions were spray-deposited on cellulose acetate backings using a nebuliser. Lateral uniformity of the deposited layer over areas ranging from several mm to several cm was accomplished by raster scanning the table on which the backing was mounted. By optimising the experimental parameters, deposition could be accomplished without any detectable wetting of delicate substrates like paper. The areal density of the deposited material was calculated from the concentration of the solute, the volume of the consumed solution and the raster scanned area. The reference standards were analysed by PIXE using an external beam chamber backfilled with helium. The Si(Li) based detection system contained a thin funny filter so that X-ray spectra could be measured down to 1 keV. The proton energy on impact was 1.1 MeV. This relatively low probe energy has the advantage of producing favourable elemental X-ray peak heights relative to the bremsstrahlung-background, notably at energies between 2 and 7 keV. Under the same conditions sufficiently high X-ray yields were achieved for heavy elements like Zn and Pb. Using large area beams, bombardment-induced stress in the backing films could be kept at a low level so that very reproducible background spectra were obtained. Hence a straightforward background subtraction routine could be employed. Sensitivities were determined for 23 elements ranging from Na to Pb. Advantages and problems associated with the different metal salts are discussed briefly.
VizieR Online Data Catalog: EBHIS spectra and HI column density maps (Winkel+, 2016)
NASA Astrophysics Data System (ADS)
Winkel, B.; Kerp, J.; Floeer, L.; Kalberla, P. M. W.; Ben Bekhti, N.; Keller, R.; Lenz, D.
2015-11-01
The EBHIS 1st data release comprises 21-cm neutral atomic hydrogen data of the Milky Way (-600km/s
Biggar, Kyle K; Wu, Cheng-Wei; Storey, Kenneth B
2014-10-01
This study makes a significant advancement on a microRNA amplification technique previously used for expression analysis and sequencing in animal models without annotated mature microRNA sequences. As research progresses into the post-genomic era of microRNA prediction and analysis, the need for a rapid and cost-effective method for microRNA amplification is critical to facilitate wide-scale analysis of microRNA expression. To facilitate this requirement, we have reoptimized the design of amplification primers and introduced a polyadenylation step to allow amplification of all mature microRNAs from a single RNA sample. Importantly, this method retains the ability to sequence reverse transcription polymerase chain reaction (RT-PCR) products, validating microRNA-specific amplification. Copyright © 2014 Elsevier Inc. All rights reserved.
Hashim, S; Al-Ahbabi, S; Bradley, D A; Webb, M; Jeynes, C; Ramli, A T; Wagiran, H
2009-03-01
Modern linear accelerators, the predominant teletherapy machine in major radiotherapy centres worldwide, provide multiple electron and photon beam energies. To obtain reasonable treatment times, intense electron beam currents are achievable. In association with this capability, there is considerable demand to validate patient dose using systems of dosimetry offering characteristics that include good spatial resolution, high precision and accuracy. Present interest is in the thermoluminescence response and dosimetric utility of commercially available doped optical fibres. The important parameter for obtaining the highest TL yield during this study is to know the dopant concentration of the SiO2 fibre because during the production of the optical fibres, the dopants tend to diffuse. To achieve this aim, proton-induced X-ray emission (PIXE), which has no depth resolution but can unambiguously identify elements and analyse for trace elements with detection limits approaching microg/g, was used. For Al-doped fibres, the dopant concentration in the range 0.98-2.93 mol% have been estimated, with equivalent range for Ge-doped fibres being 0.53-0.71 mol%. In making central-axis irradiation measurements a solid water phantom was used. For 6-MV photons and electron energies in the range 6, 9 and 12 MeV, a source to surface distance of 100 cm was used, with a dose rate of 400 cGy/min for photons and electrons. The TL measurements show a linear dose-response over the delivered range of absorbed dose from 1 to 4 Gy. Fading was found to be minimal, less than 10% over five days subsequent to irradiation. The minimum detectable dose for 6-MV photons was found to be 4, 30 and 900 microGy for TLD-100 chips, Ge- and Al-doped fibres, respectively. For 6-, 9- and 12-MeV electron energies, the minimum detectable dose were in the range 3-5, 30-50 and 800-1400 microGy for TLD-100 chip, Ge-doped and Al-doped fibres, respectively.
Particulate sulfur in the upper troposphere and lowermost stratosphere - sources and climate forcing
NASA Astrophysics Data System (ADS)
Martinsson, Bengt G.; Friberg, Johan; Sandvik, Oscar S.; Hermann, Markus; van Velthoven, Peter F. J.; Zahn, Andreas
2017-09-01
This study is based on fine-mode aerosol samples collected in the upper troposphere (UT) and the lowermost stratosphere (LMS) of the Northern Hemisphere extratropics during monthly intercontinental flights at 8.8-12 km altitude of the IAGOS-CARIBIC platform in the time period 1999-2014. The samples were analyzed for a large number of chemical elements using the accelerator-based methods PIXE (particle-induced X-ray emission) and PESA (particle elastic scattering analysis). Here the particulate sulfur concentrations, obtained by PIXE analysis, are investigated. In addition, the satellite-borne lidar aboard CALIPSO is used to study the stratospheric aerosol load. A steep gradient in particulate sulfur concentration extends several kilometers into the LMS, as a result of increasing dilution towards the tropopause of stratospheric, particulate sulfur-rich air. The stratospheric air is diluted with tropospheric air, forming the extratropical transition layer (ExTL). Observed concentrations are related to the distance to the dynamical tropopause. A linear regression methodology handled seasonal variation and impact from volcanism. This was used to convert each data point into stand-alone estimates of a concentration profile and column concentration of particulate sulfur in a 3 km altitude band above the tropopause. We find distinct responses to volcanic eruptions, and that this layer in the LMS has a significant contribution to the stratospheric aerosol optical depth and thus to its radiative forcing. Further, the origin of UT particulate sulfur shows strong seasonal variation. We find that tropospheric sources dominate during the fall as a result of downward transport of the Asian tropopause aerosol layer (ATAL) formed in the Asian monsoon, whereas transport down from the Junge layer is the main source of UT particulate sulfur in the first half of the year. In this latter part of the year, the stratosphere is the clearly dominating source of particulate sulfur in the UT during times of volcanic influence and under background conditions.
Creating Slide Show Book Reports.
ERIC Educational Resources Information Center
Taylor, Harriet G.; Stuhlmann, Janice M.
1995-01-01
Describes the use of "Kid Pix 2" software by fourth grade students to develop slide-show book reports. Highlights include collaboration with education majors from Louisiana State University, changes in attitudes of the education major students and elementary students, and problems with navigation and disk space. (LRW)
Subcellular trace element distribution in Geosiphon pyriforme
NASA Astrophysics Data System (ADS)
Maetz, Mischa; Schüßler, Arthur; Wallianos, Alexandros; Traxel, Kurt
1999-04-01
Geosiphon pyriforme is a unique endosymbiotic consortium consisting of a soil dwelling fungus and the cyanobacterium Nostoc punctiforme. At present this symbiosis becomes very interesting because of its phylogenetic relationship to the arbuscular mycorrhizal (AM) fungi. Geosiphon pyriforme could be an important model system for these obligate symbiotic fungi, which supply 80-90% of all land plant species with nutrients, in particular phosphorous and trace elements. Combined PIXE and STIM analyses of the various compartments of Geosiphon give hints for the matter exchange between the symbiotic partners and their environment and the kind of nutrient storage and acquisition, in particular related to nitrogen fixation and metabolism. To determine the quality of our PIXE results we analysed several geological and biological standards over a time period of three years. This led to an overall precision of about 6% and an accuracy of 5-10% for nearly all detectable elements. In combination with the correction model for the occurring mass loss during the analyses this holds true even for biological targets.
Surface topography of 1€ coin measured by stereo-PIXE
NASA Astrophysics Data System (ADS)
Gholami-Hatam, E.; Lamehi-Rachti, M.; Vavpetič, P.; Grlj, N.; Pelicon, P.
2013-07-01
We demonstrate the stereo-PIXE method by measurement of surface topography of the relief details on 1€ coin. Two X-ray elemental maps were simultaneously recorded by two X-ray detectors positioned at the left and the right side of the proton microbeam. The asymmetry of the yields in the pixels of the two X-ray maps occurs due to different photon attenuation on the exit travel path of the characteristic X-rays from the point of emission through the sample into the X-ray detectors. In order to calibrate the inclination angle with respect to the X-ray asymmetry, a flat inclined surface model was at first applied for the sample in which the matrix composition and the depth elemental concentration profile is known. After that, the yield asymmetry in each image pixel was transferred into corresponding local inclination angle using calculated dependence of the asymmetry on the surface inclination. Finally, the quantitative topography profile was revealed by integrating the local inclination angle over the lateral displacement of the probing beam.
NASA Astrophysics Data System (ADS)
Beguin, Y.; Bours, V.; Delbrouck, J.-M.; Robaye, G.; Roelandts, I.; Fillet, G.; Weber, G.
1990-04-01
The use of PIXE allowed for a simultaneous determination of serum copper (Cu), zinc (Zn), selenium (Se) and bromine (Br), in various groups of patients with hematologic malignancies. In 78 patients with acute nonlymphocytic leukemia, it was observed that (1) serum Se was significantly lower than in healthy controls and correlated inversely with the tumor burden; (2) serum bromine was normal at diagnosis but dropped dramatically after intensive chemotherapy, before recovering progressively over a period of months; and (3) pretreatment serum copper and zinc were significant prognostic factors of the chance to achieve a complete remission. In 50 patients with chronic lymphocytic leukemia, it was observed that (1) serum Cu and Cu/Zn ratio were useful indices of the disease activity, which were independent of a nonspecific acute phase reaction; and (2) Zn deficiency could contribute to immune dysfunction. In 119 patients with myeloproliferative disorders or myelodysplasic syndromes, serum Cu and Zn levels were mostly dependent on nonspecific factors, such as age and inflammation.
In vivo 3D PIXE-micron-CT imaging of Drosophila melanogaster using a contrast agent
NASA Astrophysics Data System (ADS)
Matsuyama, Shigeo; Hamada, Naoki; Ishii, Keizo; Nozawa, Yuichiro; Ohkura, Satoru; Terakawa, Atsuki; Hatori, Yoshinobu; Fujiki, Kota; Fujiwara, Mitsuhiro; Toyama, Sho
2015-04-01
In this study, we developed a three-dimensional (3D) computed tomography (CT) in vivo imaging system for imaging small insects with micrometer resolution. The 3D CT imaging system, referred to as 3D PIXE-micron-CT (PIXEμCT), uses characteristic X-rays produced by ion microbeam bombardment of a metal target. PIXEμCT was used to observe the body organs and internal structure of a living Drosophila melanogaster. Although the organs of the thorax were clearly imaged, the digestive organs in the abdominal cavity could not be clearly discerned initially, with the exception of the rectum and the Malpighian tubule. To enhance the abdominal images, a barium sulfate powder radiocontrast agent was added. For the first time, 3D images of the ventriculus of a living D. melanogaster were obtained. Our results showed that PIXEμCT can provide in vivo 3D-CT images that reflect correctly the structure of individual living organs, which is expected to be very useful in biological research.
ePix100 camera: Use and applications at LCLS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carini, G. A., E-mail: carini@slac.stanford.edu; Alonso-Mori, R.; Blaj, G.
2016-07-27
The ePix100 x-ray camera is a new system designed and built at SLAC for experiments at the Linac Coherent Light Source (LCLS). The camera is the first member of a family of detectors built around a single hardware and software platform, supporting a variety of front-end chips. With a readout speed of 120 Hz, matching the LCLS repetition rate, a noise lower than 80 e-rms and pixels of 50 µm × 50 µm, this camera offers a viable alternative to fast readout, direct conversion, scientific CCDs in imaging mode. The detector, designed for applications such as X-ray Photon Correlation Spectroscopymore » (XPCS) and wavelength dispersive X-ray Emission Spectroscopy (XES) in the energy range from 2 to 10 keV and above, comprises up to 0.5 Mpixels in a very compact form factor. In this paper, we report the performance of the camera during its first use at LCLS.« less
P-cadherin promotes collective cell migration via a Cdc42-mediated increase in mechanical forces
Plutoni, Cédric; Bazellieres, Elsa; Le Borgne-Rochet, Maïlys; Comunale, Franck; Brugues, Agusti; Séveno, Martial; Planchon, Damien; Thuault, Sylvie; Morin, Nathalie; Bodin, Stéphane; Trepat, Xavier
2016-01-01
Collective cell migration (CCM) is essential for organism development, wound healing, and metastatic transition, the primary cause of cancer-related death, and it involves cell–cell adhesion molecules of the cadherin family. Increased P-cadherin expression levels are correlated with tumor aggressiveness in carcinoma and aggressive sarcoma; however, how P-cadherin promotes tumor malignancy remains unknown. Here, using integrated cell biology and biophysical approaches, we determined that P-cadherin specifically induces polarization and CCM through an increase in the strength and anisotropy of mechanical forces. We show that this mechanical regulation is mediated by the P-cadherin/β-PIX/Cdc42 axis; P-cadherin specifically activates Cdc42 through β-PIX, which is specifically recruited at cell–cell contacts upon CCM. This mechanism of cell polarization and migration is absent in cells expressing E- or R-cadherin. Thus, we identify a specific role of P-cadherin through β-PIX–mediated Cdc42 activation in the regulation of cell polarity and force anisotropy that drives CCM. PMID:26783302
Radar signal analysis of ballistic missile with micro-motion based on time-frequency distribution
NASA Astrophysics Data System (ADS)
Wang, Jianming; Liu, Lihua; Yu, Hua
2015-12-01
The micro-motion of ballistic missile targets induces micro-Doppler modulation on the radar return signal, which is a unique feature for the warhead discrimination during flight. In order to extract the micro-Doppler feature of ballistic missile targets, time-frequency analysis is employed to process the micro-Doppler modulated time-varying radar signal. The images of time-frequency distribution (TFD) reveal the micro-Doppler modulation characteristic very well. However, there are many existing time-frequency analysis methods to generate the time-frequency distribution images, including the short-time Fourier transform (STFT), Wigner distribution (WD) and Cohen class distribution, etc. Under the background of ballistic missile defence, the paper aims at working out an effective time-frequency analysis method for ballistic missile warhead discrimination from the decoys.
NASA Astrophysics Data System (ADS)
Pålsgård, Eva; Johansson, Carina; Li, Gang; Grime, Geoff W.; Triffitt, J. T.
1997-07-01
To respond to varying environmental demands the bone tissue in the body is under continual reconstruction throughout life. It is known that metallic elements are important for maintaining normal bone structure, but their roles are not well understood. More information about the effects of metal excess or deficiency is needed to help in the development of metallic bone implants and to improve the treatment of bone fractures and defects. The Oxford Scanning Proton Microprobe (SPM) is being applied in two studies involving metal ions in bone: (1) bone regrowth and bonding to titanium bone implants may be influenced by diffusion of Ti ions into the bone. We are using microPIXE to determine the metal ion content of bone developing in contact with implants of pure Nb, Ti and Ti alloys. (2) Bone lengthening as a surgical procedure is induced by fracturing the bone and allowing it to heal with a small gap between the fractured ends created by the use of external fixators. The gap can be slowly increased during the healing process to stimulate the production of new bone. The enzymes and other constituents of the developing bone need certain metals for their function. Using experimental animals we have studied the concentrations of the metals and whether a deficiency of trace metals limits the optimum rate of bone lengthening.
NASA Astrophysics Data System (ADS)
Qiu, J. P.; Niu, D. X.
Micro-grid is one of the key technologies of the future energy supplies. Take economic planning. reliability, and environmental protection of micro grid as a basis for the analysis of multi-strategy objective programming problems for micro grid which contains wind power, solar power, and battery and micro gas turbine. Establish the mathematical model of each power generation characteristics and energy dissipation. and change micro grid planning multi-objective function under different operating strategies to a single objective model based on AHP method. Example analysis shows that in combination with dynamic ant mixed genetic algorithm can get the optimal power output of this model.
How C2 Goes Wrong (Briefing Chart)
2014-06-01
Guardian/Pix/pictures/2012/12/19/1355903591995/Hillsborough-disaster-010.jpg Cases (3): Disaster/Emergency Response (Cont.) Columbine High School ...r337173_1529332.jpg http://bossip.files.wordpress.com/2012/11/ massacre -e1352384704110.jpeg?w=625&h=389 The Punchline “What we’ve got here, is
Surface protection coating material for controlling the decay of major construction stone
NASA Astrophysics Data System (ADS)
Arun, T.; Ray, D. K.; Gupta, V. P.; Panda, S. S.; Sahoo, P. K.; Ghosh, Jaydip; Sengupta, Pranesh; Satyam, P. V.
2017-05-01
Degradation of the building stones are creating instability in the old building and monuments which is to be protected. To investigate the characteristics of such a stones used for the construction in eastern India, we have collected the khondalite stones. The microstructural and elemental composition analysis of the khondalite stones are analyzed by using SEM, EDX and PIXE trace elemental analysis. We have prepared surface protection coating material with graphene oxide and cobalt ferrite as a base material along with other residuals. The prepared coating materials is coated on the galvanized iron substrate for further characterization. The surface morphology characteristics of the coating material is analyzed by SEM and AFM. The corrosion resistance characteristics of the prepared coating material is studied by the electrochemical impedance spectroscopy. The results suggests that the prepared coating material can be used as a surface protection materials to control the self-destruction of khondalite stones.
IBA analysis of some precolumbian gilded-copper samples
NASA Astrophysics Data System (ADS)
Andrade, E.; Murillo, G.; Policroniades, R.; Acosta, L.; Zavala, E. P.; Rocha, M. F.; Centeno, S. A.
2005-10-01
The elemental composition and depth profiles obtained by IBA techniques on some gilded-copper fragments from the Moche site of Loma Negra, in the Piura Valley, on the Northern Coast of Perú are presented in this article. A previous radiocarbon dating of a wooden fragment indicated that Loma Negra was occupied around 295 AD. A PIXE analysis using a 2.6 MeV external proton beam, was used to obtain the concentration of trace elements in the samples. RBS analyses using 2.72 MeV 4He+ and 12.0 MeV 12C3+ were used to obtain the Au, Ag, Cu atomic profiles. NRA with a 1.02 MeV deuteron beam was used to measure the oxygen and carbon concentrations through the 16O(d,p) 17O, 16O(d,α) 14N and 12C(d,p0) 13C reactions.
Monetary alloys in Iron Age Armorica (Finistère, France): The singular case of the Osismi tribe
NASA Astrophysics Data System (ADS)
Guerra, M. F.; Abollivier, Ph.
2016-06-01
The analysis by PIXE and PAA of 64 coins struck in Iron Age Armorica by the Osismi tribe revealed the use of a different system from the usual Celtic Gaul tri-metallic system. The gold-based alloy (Au-Ag-Cu) firstly issued is debased over time to become a silver-based alloy (Ag-Cu-Sn). Based on the analytical data, two chronological phases were defined and dates of issuing could be ascribed to the coin-types. The presence of Sn and Sb in the alloys and the low contents of Pb were used in the attribution of 9 specimens of unknown origin to the Osismi monetary system. Considerations on the mints supplies could also be provided.
Jamieson, H.E.; Robinson, C.; Alpers, Charles N.; McCleskey, R. Blaine; Nordstrom, D. Kirk; Peterson, Ronald C.
2005-01-01
Copiapite-group minerals of the general formula AR4 (SO4)6(OH)2??nH2O, where A is predominantly Mg, Fe2+, or 0.67Al3+, R is predominantly Fe3+, and n is typically 20, are among several secondary hydrous Fe sulfates occurring in the inactive mine workings of the massive sulfide deposit at Iron Mountain, CA, a USEPA Superfund site that produces extremely acidic drainage. Samples of copiapite-group minerals, some with coexisting water, were collected from the Richmond mine. Approximately 200 mL of brownish pore water with a pH of -0.9 were extracted through centrifugation from a 10-L sample of moist copiapite-group minerals taken from pyritic muck piles. The pore water is extremely rich in ferric iron (Fe3+=149 g L-1, FeT=162 g L-1 and has a density of 1.52 g mL-1. The composition of the pore water is interpreted in the context of published phase relations in the Fe2O3- SO3-H2O system and previous work on the chemistry of extremely acid mine waters and associated minerals in the Richmond mine. Two distinct members of the copiapite mineral group were identified in the samples with coexisting water: (1) abundant magnesiocopiapite consisting of platy crystals 10 to 50 ??m and (2) minor aluminocopiapite present as smaller platy crystals that form spheroidal aggregates. The average composition (n=5) of the magnesiocopiapite is (Mg0.90Fe0.172+ Zn0.02Cu0.01)???1.10(Fe3.833+Al0.09)???3.92(SO4) 6.00(OH)1.96??20H2O. Bulk compositions determined by digestion and wet-chemical analysis are consistent with the microanalytical results. These results suggest that magnesiocopiapite is the least soluble member of the copiapite group under the prevailing conditions. Micro-PIXE analysis indicates that the copiapite-group minerals in this sample sequester Zn (average 1420 ppm), with lesser amounts of Cu (average 270 ppm) and As (average 64 ppm). ?? 2004 Elsevier B.V. All rights reserved.
Intelligent Operation and Maintenance of Micro-grid Technology and System Development
NASA Astrophysics Data System (ADS)
Fu, Ming; Song, Jinyan; Zhao, Jingtao; Du, Jian
2018-01-01
In order to achieve the micro-grid operation and management, Studying the micro-grid operation and maintenance knowledge base. Based on the advanced Petri net theory, the fault diagnosis model of micro-grid is established, and the intelligent diagnosis and analysis method of micro-grid fault is put forward. Based on the technology, the functional system and architecture of the intelligent operation and maintenance system of micro-grid are studied, and the microcomputer fault diagnosis function is introduced in detail. Finally, the system is deployed based on the micro-grid of a park, and the micro-grid fault diagnosis and analysis is carried out based on the micro-grid operation. The system operation and maintenance function interface is displayed, which verifies the correctness and reliability of the system.
NASA Technical Reports Server (NTRS)
Flynn, G. J.; Sutton, S. R.
1989-01-01
Trace element analyses were performed on bulk cosmic dust particles by Proton Induced X Ray Emission (PIXE) and Synchrotron X Ray Fluorescence (SXRF). When present at or near chondritic abundances the trace elements K, Ti, Cr, Mn, Cu, Zn, Ga, Ge, Se, and Br are presently detectable by SXRF in particles of 20 micron diameter. Improvements to the SXRF analysis facility at the National Synchrotron Light Source presently underway should increase the range of detectable elements and permit the analysis of smaller samples. In addition the Advanced Photon Source will be commissioned at Argonne National Laboratory in 1995. This 7 to 8 GeV positron storage ring, specifically designed for high-energy undulator and wiggler insertion devices, will be an ideal source for an x ray microprobe with one micron spatial resolution and better than 100 ppb elemental sensitivity for most elements. Thus trace element analysis of individual micron-sized grains should be possible by the time of the comet nucleus sample return mission.
Signature analysis of ballistic missile warhead with micro-nutation in terahertz band
NASA Astrophysics Data System (ADS)
Li, Ming; Jiang, Yue-song
2013-08-01
In recent years, the micro-Doppler effect has been proposed as a new technique for signature analysis and extraction of radar targets. The ballistic missile is known as a typical radar target and has been paid many attentions for the complexities of its motions in current researches. The trajectory of a ballistic missile can be generally divided into three stages: boost phase, midcourse phase and terminal phase. The midcourse phase is the most important phase for radar target recognition and interception. In this stage, the warhead forms a typical micro-motion called micro-nutation which consists of three basic micro-motions: spinning, coning and wiggle. This paper addresses the issue of signature analysis of ballistic missile warhead in terahertz band via discussing the micro-Doppler effect. We establish a simplified model (cone-shaped) for the missile warhead followed by the micro-motion models including of spinning, coning and wiggle. Based on the basic formulas of these typical micro-motions, we first derive the theoretical formula of micro-nutation which is the main micro-motion of the missile warhead. Then, we calculate the micro-Doppler frequency in both X band and terahertz band via these micro-Doppler formulas. The simulations are given to show the superiority of our proposed method for the recognition and detection of radar micro targets in terahertz band.
Jung, SeungWoo; Bohan, Amy
2018-02-01
OBJECTIVE To characterize expression profiles of circulating microRNAs via genome-wide sequencing for dogs with congestive heart failure (CHF) secondary to myxomatous mitral valve degeneration (MMVD). ANIMALS 9 healthy client-owned dogs and 8 age-matched client-owned dogs with CHF secondary to MMVD. PROCEDURES Blood samples were collected before administering cardiac medications for the management of CHF. Isolated microRNAs from plasma were classified into microRNA libraries and subjected to next-generation sequencing (NGS) for genome-wide sequencing analysis and quantification of circulating microRNAs. Quantitative reverse transcription PCR (qRT-PCR) assays were used to validate expression profiles of differentially expressed circulating microRNAs identified from NGS analysis of dogs with CHF. RESULTS 326 microRNAs were identified with NGS analysis. Hierarchical analysis revealed distinct expression patterns of circulating microRNAs between healthy dogs and dogs with CHF. Results of qRT-PCR assays confirmed upregulation of 4 microRNAs (miR-133, miR-1, miR-let-7e, and miR-125) and downregulation of 4 selected microRNAs (miR-30c, miR-128, miR-142, and miR-423). Results of qRT-PCR assays were highly correlated with NGS data and supported the specificity of circulating microRNA expression profiles in dogs with CHF secondary to MMVD. CONCLUSIONS AND CLINICAL RELEVANCE These results suggested that circulating microRNA expression patterns were unique and could serve as molecular biomarkers of CHF in dogs with MMVD.
NASA Astrophysics Data System (ADS)
1999-11-01
First Images from FORS2 at VLT KUEYEN on Paranal The first, major astronomical instrument to be installed at the ESO Very Large Telescope (VLT) was FORS1 ( FO cal R educer and S pectrograph) in September 1998. Immediately after being attached to the Cassegrain focus of the first 8.2-m Unit Telescope, ANTU , it produced a series of spectacular images, cf. ESO PR 14/98. Many important observations have since been made with this outstanding facility. Now FORS2 , its powerful twin, has been installed at the second VLT Unit Telescope, KUEYEN . It is the fourth major instrument at the VLT after FORS1 , ISAAC and UVES.. The FORS2 Commissioning Team that is busy installing and testing this large and complex instrument reports that "First Light" was successfully achieved already on October 29, 1999, only two days after FORS2 was first mounted at the Cassegrain focus. Since then, various observation modes have been carefully tested, including normal and high-resolution imaging, echelle and multi-object spectroscopy, as well as fast photometry with millisecond time resolution. A number of fine images were obtained during this work, some of which are made available with the present Press Release. The FORS instruments ESO PR Photo 40a/99 ESO PR Photo 40a/99 [Preview - JPEG: 400 x 345 pix - 203k] [Normal - JPEG: 800 x 689 pix - 563kb] [Full-Res - JPEG: 1280 x 1103 pix - 666kb] Caption to PR Photo 40a/99: This digital photo shows the twin instruments, FORS2 at KUEYEN (in the foreground) and FORS1 at ANTU, seen in the background through the open ventilation doors in the two telescope enclosures. Although they look alike, the two instruments have specific functions, as described in the text. FORS1 and FORS2 are the products of one of the most thorough and advanced technological studies ever made of a ground-based astronomical instrument. They have been specifically designed to investigate the faintest and most remote objects in the universe. They are "multi-mode instruments" that may be used in several different observation modes. FORS2 is largely identical to FORS1 , but there are a number of important differences. For example, it contains a Mask Exchange Unit (MXU) for laser-cut star-plates [1] that may be inserted at the focus, allowing a large number of spectra of different objects, in practice up to about 70, to be taken simultaneously. Highly sophisticated software assigns slits to individual objects in an optimal way, ensuring a great degree of observing efficiency. Instead of the polarimetry optics found in FORS1 , FORS2 has new grisms that allow the use of higher spectral resolutions. The FORS project was carried out under ESO contract by a consortium of three German astronomical institutes, the Heidelberg State Observatory and the University Observatories of Göttingen and Munich. The participating institutes have invested a total of about 180 man-years of work in this unique programme. The photos below demonstrate some of the impressive possibilities with this new instrument. They are based on observations with the FORS2 standard resolution collimator (field size 6.8 x 6.8 armin = 2048 x 2048 pixels; 1 pixel = 0.20 arcsec). In addition, observations of the Crab pulsar demonstrate a new observing mode, high-speed photometry. Protostar HH-34 in Orion ESO PR Photo 40b/99 ESO PR Photo 40b/99 [Preview - JPEG: 400 x 444 pix - 220kb] [Normal - JPEG: 800 x 887 pix - 806kb] [Full-Res - JPEG: 2000 x 2217 pix - 3.6Mb] The Area around HH-34 in Orion ESO PR Photo 40c/99 ESO PR Photo 40c/99 [Preview - JPEG: 400 x 494 pix - 262kb] [Full-Res - JPEG: 802 x 991 pix - 760 kb] The HH-34 Superjet in Orion (centre) PR Photo 40b/99 shows a three-colour composite of the young object Herbig-Haro 34 (HH-34) , now in the protostar stage of evolution. It is based on CCD frames obtained with the FORS2 instrument in imaging mode, on November 2 and 6, 1999. This object has a remarkable, very complicated appearance that includes two opposite jets that ram into the surrounding interstellar matter. This structure is produced by a machine-gun-like blast of "bullets" of dense gas ejected from the star at high velocities (approaching 250 km/sec). This seems to indicate that the star experiences episodic "outbursts" when large chunks of material fall onto it from a surrounding disk. HH-34 is located at a distance of approx. 1,500 light-years, near the famous Orion Nebula , one of the most productive star birth regions. Note also the enigmatic "waterfall" to the upper left, a feature that is still unexplained. PR Photo 40c/99 is an enlargement of a smaller area around the central object. Technical information : Photo 40b/99 is based on a composite of three images taken through three different filters: B (wavelength 429 nm; Full-Width-Half-Maximum (FWHM) 88 nm; exposure time 10 min; here rendered as blue), H-alpha (centered on the hydrogen emission line at wavelength 656 nm; FWHM 6 nm; 30 min; green) and S II (centrered at the emission lines of inonized sulphur at wavelength 673 nm; FWHM 6 nm; 30 min; red) during a period of 0.8 arcsec seeing. The field shown measures 6.8 x 6.8 arcmin and the images were recorded in frames of 2048 x 2048 pixels, each measuring 0.2 arcsec. The Full Resolution version shows the original pixels. North is up; East is left. N 70 Nebula in the Large Magellanic Cloud ESO PR Photo 40d/99 ESO PR Photo 40d/99 [Preview - JPEG: 400 x 444 pix - 360kb] [Normal - JPEG: 800 x 887 pix - 1.0Mb] [Full-Res - JPEG: 1997 x 2213 pix - 3.4Mb] The N 70 Nebula in the LMC ESO PR Photo 40e/99 ESO PR Photo 40e/99 [Preview - JPEG: 400 x 485 pix - 346kb] [Full-Res - JPEG: 986 x 1196 pix - 1.2Mb] The N70 Nebula in the LMC (detail) PR Photo 40d/99 shows a three-colour composite of the N 70 nebula. It is a "Super Bubble" in the Large Magellanic Cloud (LMC) , a satellite galaxy to the Milky Way system, located in the southern sky at a distance of about 160,000 light-years. This photo is based on CCD frames obtained with the FORS2 instrument in imaging mode in the morning of November 5, 1999. N 70 is a luminous bubble of interstellar gas, measuring about 300 light-years in diameter. It was created by winds from hot, massive stars and supernova explosions and the interior is filled with tenuous, hot expanding gas. An object like N70 provides astronomers with an excellent opportunity to explore the connection between the lifecycles of stars and the evolution of galaxies. Very massive stars profoundly affect their environment. They stir and mix the interstellar clouds of gas and dust, and they leave their mark in the compositions and locations of future generations of stars and star systems. PR Photo 40e/99 is an enlargement of a smaller area of this nebula. Technical information : Photos 40d/99 is based on a composite of three images taken through three different filters: B (429 nm; FWHM 88 nm; 3 min; here rendered as blue), V (554 nm; FWHM 111 nm; 3 min; green) and H-alpha (656 nm; FWHM 6 nm; 3 min; red) during a period of 1.0 arcsec seeing. The field shown measures 6.8 x 6.8 arcmin and the images were recorded in frames of 2048 x 2048 pixels, each measuring 0.2 arcsec. The Full Resolution version shows the original pixels. North is up; East is left. The Crab Nebula in Taurus ESO PR Photo 40f/99 ESO PR Photo 40f/99 [Preview - JPEG: 400 x 446 pix - 262k] [Normal - JPEG: 800 x 892 pix - 839 kb] [Full-Res - JPEG: 2036 x 2269 pix - 3.6Mb] The Crab Nebula in Taurus ESO PR Photo 40g/99 ESO PR Photo 40g/99 [Preview - JPEG: 400 x 444 pix - 215kb] [Full-Res - JPEG: 817 x 907 pix - 485 kb] The Crab Nebula in Taurus (detail) PR Photo 40f/99 shows a three colour composite of the well-known Crab Nebula (also known as "Messier 1" ), as observed with the FORS2 instrument in imaging mode in the morning of November 10, 1999. It is the remnant of a supernova explosion at a distance of about 6,000 light-years, observed almost 1000 years ago, in the year 1054. It contains a neutron star near its center that spins 30 times per second around its axis (see below). PR Photo 40g/99 is an enlargement of a smaller area. More information on the Crab Nebula and its pulsar is available on the web, e.g. at a dedicated website for Messier objects. In this picture, the green light is predominantly produced by hydrogen emission from material ejected by the star that exploded. The blue light is predominantly emitted by very high-energy ("relativistic") electrons that spiral in a large-scale magnetic field (so-called syncrotron emission ). It is believed that these electrons are continuously accelerated and ejected by the rapidly spinning neutron star at the centre of the nebula and which is the remnant core of the exploded star. This pulsar has been identified with the lower/right of the two close stars near the geometric center of the nebula, immediately left of the small arc-like feature, best seen in PR Photo 40g/99 . Technical information : Photo 40f/99 is based on a composite of three images taken through three different optical filters: B (429 nm; FWHM 88 nm; 5 min; here rendered as blue), R (657 nm; FWHM 150 nm; 1 min; green) and S II (673 nm; FWHM 6 nm; 5 min; red) during periods of 0.65 arcsec (R, S II) and 0.80 (B) seeing, respectively. The field shown measures 6.8 x 6.8 arcmin and the images were recorded in frames of 2048 x 2048 pixels, each measuring 0.2 arcsec. The Full Resolution version shows the original pixels. North is up; East is left. The High Time Resolution mode (HIT) of FORS2 ESO PR Photo 40h/99 ESO PR Photo 40h/99 [Preview - JPEG: 400 x 304 pix - 90kb] [Normal - JPEG: 707 x 538 pix - 217kb] Time Sequence of the Pulsar in the Crab Nebula ESO PR Photo 40i/99 ESO PR Photo 40i/99 [Preview - JPEG: 400 x 324 pix - 42kb] [Normal - JPEG: 800 x 647 pix - 87kb] Lightcurve of the Pulsar in the Crab Nebula In combination with the large light collecting power of the VLT Unit Telescopes, the high time resolution (25 nsec = 0.000000025 sec) of the ESO-developed FIERA CCD-detector controller opens a new observing window for celestial objects that undergo light intensity variations on very short time scales. A first implementation of this type of observing mode was tested with FORS2 during the first commissioning phase, by means of one of the most fascinating astronomical objects, the rapidly spinning neutron star in the Crab Nebula . It is also known as the Crab pulsar and is an exceedingly dense object that represents an extreme state of matter - it weighs as much as the Sun, but measures only about 30 km across. The result presented here was obtained in the so-called trailing mode , during which one of the rectangular openings of the Multi-Object Spectroscopy (MOS) assembly within FORS2 is placed in front of the lower end of the field. In this way, the entire surface of the CCD is covered, except the opening in which the object under investigation is positioned. By rotating this opening, some neighbouring objects (e.g. stars for alignment) may be observed simultaneously. As soon as the shutter is opened, the charges on the chip are progressively shifted upwards, one pixel at a time, until those first collected in the bottom row behind the opening have reached the top row. Then the entire CCD is read out and the digital data with the full image is stored in the computer. In this way, successive images (or spectra) of the object are recorded in the same frame, displaying the intensity variation with time during the exposure. For this observation, the total exposure lasted 2.5 seconds. During this time interval the image of the pulsar (and those of some neighbouring stars) were shifted 2048 times over the 2048 rows of the CCD. Each individual exposure therefore lasted exactly 1.2 msec (0.0012 sec), corresponding to a nominal time-resolution of 2.4 msec (2 pixels). Faster or slower time resolutions are possible by increasing or decreasing the shift and read-out rate [2]. In ESO PR Photo 40h/99 , the continuous lines in the top and bottom half are produced by normal stars of constant brightness, while the series of dots represents the individual pulses of the Crab pulsar, one every 33 milliseconds (i.e. the neutron star rotates around its axis 30 times per second). It is also obvious that these dots are alternatively brighter and fainter: they mirror the double-peaked profile of the light pulses, as shown in ESO PR Photo 40i/99 . In this diagramme, the time increases along the abscissa axis (1 pixel = 1.2 msec) and the momentary intensity (uncalibrated) is along the ordinate axis. One full revolution of the neutron star corresponds to the distance from one high peak to the next, and the diagramme therefore covers six consecutive revolutions (about 200 milliseconds). Following thorough testing, this new observing mode will allow to investigate the brightness variations of this and many other objects in great detail in order to gain new and fundamental insights in the physical mechanisms that produce the radiation pulses. In addition, it is foreseen to do high time resolution spectroscopy of rapidly varying phenomena. Pushing it to the limits with an 8.2-m telescope like KUEYEN will be a real challenge to the observers that will most certainly lead to great and exciting research projects in various fields of modern astrophysics. Technical information : The frame shown in Photo 40h/99 was obtained during a total exposure time of 2.5 sec without any optical filtre. During this time, the charges on the CCD were shifted over 2048 rows; each row was therefore exposed during 1.2 msec. The bright continuous line comes from the star next to the pulsar; the orientation was such that the "observation slit" was placed over two neighbouring stars. Preliminary data reduction: 11 pixels were added across the pulsar image to increase the signal-to-noise ratio and the background light from the Crab Nebula was subtracted for the same reason. Division by a brighter star (also background-subtracted, but not shown in the image) helped to reduce the influence of the Earth's atmosphere. Notes [1] The masks are produced by the Mask Manufacturing Unit (MMU) built by the VIRMOS Consortium for the VIMOS and NIRMOS instruments that will be installed at the VLT MELIPAL and YEPUN telescopes, respectively. [2] The time resolution achieved during the present test was limited by the maximum charge transfer rate of this particular CCD chip; in the future, FORS2 may be equipped with a new chip with a rate that is up to 20 times faster. How to obtain ESO Press Information ESO Press Information is made available on the World-Wide Web (URL: http://www.eso.org../ ). ESO Press Photos may be reproduced, if credit is given to the European Southern Observatory.
Development and analysis of new type microresonator with electro-optic feedback
NASA Astrophysics Data System (ADS)
Janusas, Giedrius; Palevicius, Arvydas; Cekas, Elingas; Brunius, Alfredas; Bauce, Jokubas
2016-04-01
Micro-resonators are fundamental components integrated in a hosts of MEMS applications: safety and stability systems, biometric sensors, switches, mechanical filters, micro-mirror devices, material characterization, gyroscopes, etc. A constituent part of the micro-resonator is a diffractive optical element (DOE). Different methods and materials are used to produce diffraction gratings for DOEs. Two-dimensional or three-dimensional periodic structures of micrometer-scale period are widely used in microsystems or their components. They can be used as elements for micro-scale synthesis, processing, and analysis of chemical and biological samples. On the other hand micro-resonator was designed using composite piezoelectric material. In case when microscopes, vibrometers or other direct measurement methods are destructive and hardly can be employed for in-situ analysis, indirect measurement of electrical signal generated by composite piezoelectric layer allows to measure natural frequency changes. Also piezoelectric layer allows to create a novel micro-resonator with controllable parameters, which could assure much higher functionality of micro-electromechanical systems. The novel micro-resonator for pollution detection is proposed. Mathematical model of the micro-resonator and its dynamical, electrical and optical characteristics are presented.
Analysis of Membrane Lipids of Airborne Micro-Organisms
NASA Technical Reports Server (NTRS)
MacNaughton, Sarah
2006-01-01
A method of characterization of airborne micro-organisms in a given location involves (1) large-volume filtration of air onto glass-fiber filters; (2) accelerated extraction of membrane lipids of the collected micro-organisms by use of pressurized hot liquid; and (3) identification and quantitation of the lipids by use of gas chromatography and mass spectrometry. This method is suitable for use in both outdoor and indoor environments; for example, it can be used to measure airborne microbial contamination in buildings ("sick-building syndrome"). The classical approach to analysis of airborne micro-organisms is based on the growth of cultureable micro-organisms and does not provide an account of viable but noncultureable micro-organisms, which typically amount to more than 90 percent of the micro-organisms present. In contrast, the present method provides an account of all micro-organisms, including cultureable, noncultureable, aerobic, and anaerobic ones. The analysis of lipids according to this method makes it possible to estimate the number of viable airborne micro-organisms present in the sampled air and to obtain a quantitative profile of the general types of micro-organisms present along with some information about their physiological statuses.
NASA Astrophysics Data System (ADS)
Xia, C. D.; Ge, L. J.; Liu, M. T.; Zhu, J. J.; An, Z.; Bai, B.
2018-02-01
The work presented here carried out elemental analyses on 60 porcelain shards of Tang and Song Dynasties, unearthed from Yongjinwan zone at Jinsha site, Sichuan, China, using a combination of PIXE and RBS methods. Six shards from Liulichang kiln site and 6 from Shifangtang kiln site were also analyzed as reference materials. The factor analyses for the elemental compositions in the bodies and glazes of the total 72 porcelain shards have been performed to explore their similarities and differences. Combining the results of factor analyses on elements in bodies and glazes and the classification by traditional archaeological criteria, the provenances for most of shards unearthed from Yongjinwan zone in Jinsha site could be determined. Majority of shards with a Qiong-kiln style were found as products of Liulichang kiln, this is consistent with Yongjinwan's geographical location and social environment, i.e., Yongjinwan was a suburban settlement nearest to Liulichang kiln in ancient times. Although both products of Liulichang kiln and Shifangtang kiln belonged to Qiong-kiln system and they shared a similar appearance such as red body and celadon glaze, there were distinct differences in chemical composition which could be unraveled by PIXE-RBS measurements and factor analysis. There were no apparent differences of chemical compositions for the same kinds of body and glaze between Tang and Song Dynasties, which may suggest that raw materials and production techniques for the same kinds of body and glaze continued between Tang and Song Dynasties. The chemical characteristics for each kind of body and glaze and the correlations between element composition and porcelain appearance were also obtained in this work.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robertson, J.D.; Blanchard, L.J.; Srikantapura, S.
1996-12-31
The minor- and trace-element content of coal is of great interest because of the potentially hazardous impact on human health and the environment resulting from their release during coal combustion. Of the one billion tons of coal mined annually in the United States, 85-90% is consumed by coal-fired power plants. Potentially toxic elements present at concentrations as low as a few egg can be released in large quantities from combustion of this magnitude. Of special concern are those trace elements that occur naturally in coal which have been designated as potential hazardous air pollutants (HAPs) in the 1990 Amendments tomore » the Clean Air Act. The principle objective of this work was to investigate a combination of physical and chemical coal cleaning techniques to remove 90 percent of HAP trace elements at 90 percent combustibles recovery from Kentucky No. 9 coal. Samples of this coal were first subjected to physical separation by flotation in a Denver cell. The float fraction from the Denver cell was then used as feed material for hydrothermal leaching tests in which the efficacy of dilute alkali (NaOH) and acid (HNO{sub 3}) solutions at various temperatures and pressures was investigated. The combined column flotation and mild chemical cleaning strategy removed 60-80% of trace elements with greater than 85, recovery of combustibles from very finely ground (-325 mesh) coal. The elemental composition of the samples generated at each stage was determined using particle induced X-ray emission (PIXE) analysis. PIXE is a rapid, instrumental technique that, in principle, is capable of analyzing all elements from sodium through uranium with sensitivities as low as 1 {mu}g/g.« less
Identification of deposit types of natural corundum by PIXE
NASA Astrophysics Data System (ADS)
Chulapakorn, T.; Intarasiri, S.; Bootkul, D.; Singkarat, S.
2014-07-01
Natural corundum, one of the most important exports of Thailand, is a rare, durable and valuable gemstone. The value of these precious stones is determined by their visual appearances, including brilliance, color, fire (light dispersion) and luster. Corundum is an allochromatic mineral whose trace element concentration depends on the origin and has influence on price setting. This work attempts to use an alternative method to identify the geological deposits of rubies and sapphires found in the Thai market which came from various countries, e.g., Africa, Cambodia, Myanmar, Sri Lanka, Thailand and USA. Interrelations between most important major trace elements are the main results of this work. Quantitative analysis of trace elements were performed by particle-induced X-ray emission (PIXE) technique, using 2-MeV proton beam generated and accelerated by the 1.7 MV tandem accelerator at Chiang Mai University. The trace elements of interest are Ti, Cr, Fe and Ga. We have found that the relationships between the ratios of trace element concentration can be used to classify the deposit type. Moreover, this method shows a clear separation between two main types of geological deposits, basaltic and metamorphic deposits, which further helps in determining the gemstone origin. For example, the gemstones from Cambodia, Thailand and the USA can be classified as the basaltic deposits with their high concentration in Fe but low in Ti, while the gemstones from Africa, Myanmar and Sri Lanka are metamorphic deposits because they have low Fe but high Ti concentrations. Both deposits required plots of pairs of trace elements and their ratios in population field appearance in order to distinguish their origins. The advantageous of these methods appear to be a new and a sustainable procedure for determining gemstone origins.
PIXE analysis of some Nigerian anti-diabetic medicinal plants (II)
NASA Astrophysics Data System (ADS)
Olabanji, S. O.; Adebajo, A. C.; Omobuwajo, O. R.; Ceccato, D.; Buoso, M. C.; Moschini, G.
2014-01-01
Diabetes mellitus, a metabolic disease characterized by high blood glucose levels (hyperglycemia) due to defects in insulin secretion, or action, or both, is a debilitating disease leading to other complications and death of many people in the world. Some of the medicinal plants implicated in the herbal recipes for the treatment of diabetes in Nigeria have been reported. Additional medicinal plants used for the treatment of diabetes in Nigeria are presented in this work. These medicinal plants are becoming increasingly important and relevant as herbal drugs due to their use as antioxidants, nutraceuticals, food additives and supplements in combating diabetes. Elemental compositions of these anti-diabetic medicinal plants were determined using PIXE technique. The 1.8 MV collimated proton beam from the 2.5 MV AN 2000 Van de Graaff accelerator at Istituto Nazionale di Fisica Nucleare (INFN), Laboratori Nazionali di Legnaro (LNL) Legnaro (Padova) Italy was employed for the work. The results show the detection of twenty-one elements which include Mg, P, Ca, K, Mn, Cu, Zn, S, Cr, Co, Ni and V that are implicated in the regulation of insulin and the control of the blood-sugar levels in the human body. The entire plant of Boerhavia diffusa, Securidaca longipedunculata stem, leaves of Peperomia pellucida, Macrosphyra longistyla, Olax subscorpioidea, Phyllanthus muerillanus, Jatropha gossypifolia, Cassia occidentalis, Phyllanthus amarus, and leaf and stem of Murraya koenigii, which have high concentrations of these elements could be recommended as vegetables, nutraceuticals, food additives, supplements and drugs in the control and management of diabetes, if toxicity profiles indicate that they are safe. However, significantly high contents of Al and Si in the entire plant of Bryophyllum pinnatum, and As, Cr, and Cu in Ocimum gratissimum leaf suggest that these plants should be avoided by diabetic patients to prevent complications.
Micro-Doppler analysis of multiple frequency continuous wave radar signatures
NASA Astrophysics Data System (ADS)
Anderson, Michael G.; Rogers, Robert L.
2007-04-01
Micro-Doppler refers to Doppler scattering returns produced by non rigid-body motion. Micro-Doppler gives rise to many detailed radar image features in addition to those associated with bulk target motion. Targets of different classes (for example, humans, animals, and vehicles) produce micro-Doppler images that are often distinguishable even by nonexpert observers. Micro-Doppler features have great potential for use in automatic target classification algorithms. Although the potential benefit of using micro-Doppler in classification algorithms is high, relatively little experimental (non-synthetic) micro-Doppler data exists. Much of the existing experimental data comes from highly cooperative targets (human or vehicle targets directly approaching the radar). This research involved field data collection and analysis of micro-Doppler radar signatures from non-cooperative targets. The data was collected using a low cost Xband multiple frequency continuous wave (MFCW) radar with three transmit frequencies. The collected MFCW radar signatures contain data from humans, vehicles, and animals. The presented data includes micro-Doppler signatures previously unavailable in the literature such as crawling humans and various animal species. The animal micro-Doppler signatures include deer, dog, and goat datasets. This research focuses on the analysis of micro-Doppler from noncooperative targets approaching the radar at various angles, maneuvers, and postures.
microRNA Profiling of Amniotic Fluid: Evidence of Synergy of microRNAs in Fetal Development.
Sun, Tingting; Li, Weiyun; Li, Tianpeng; Ling, Shucai
2016-01-01
Amniotic fluid (AF) continuously exchanges molecules with the fetus, playing critical roles in fetal development especially via its complex components. Among these components, microRNAs are thought to be transferred between cells loaded in microvesicles. However, the functions of AF microRNAs remain unknown. To date, few studies have examined microRNAs in amniotic fluid. In this study, we employed miRCURY Locked Nucleotide Acid arrays to profile the dynamic expression of microRNAs in AF from mice on embryonic days E13, E15, and E17. At these times, 233 microRNAs were differentially expressed (p< 0.01), accounting for 23% of the total Mus musculus microRNAs. These differentially-expressed microRNAs were divided into two distinct groups based on their expression patterns. Gene ontology analysis showed that the intersectional target genes of these differentially-expressed microRNAs were mainly distributed in synapse, synaptosome, cell projection, and cytoskeleton. Pathway analysis revealed that the target genes of the two groups of microRNAs were synergistically enriched in axon guidance, focal adhesion, and MAPK signaling pathways. MicroRNA-mRNA network analysis and gene- mapping showed that these microRNAs synergistically regulated cell motility, cell proliferation and differentiation, and especially the axon guidance process. Cancer pathways associated with growth and proliferation were also enriched in AF. Taken together, the results of this study are the first to show the functions of microRNAs in AF during fetal development, providing novel insights into interpreting the roles of AF microRNAs in fetal development.
Another Look at an Enigmatic New World
NASA Astrophysics Data System (ADS)
2005-02-01
VLT NACO Performs Outstanding Observations of Titan's Atmosphere and Surface On January 14, 2005, the ESA Huygens probe arrived at Saturn's largest satellite, Titan. After a faultless descent through the dense atmosphere, it touched down on the icy surface of this strange world from where it continued to transmit precious data back to the Earth. Several of the world's large ground-based telescopes were also active during this exciting event, observing Titan before and near the Huygens encounter, within the framework of a dedicated campaign coordinated by the members of the Huygens Project Scientist Team. Indeed, large astronomical telescopes with state-of-the art adaptive optics systems allow scientists to image Titan's disc in quite some detail. Moreover, ground-based observations are not restricted to the limited period of the fly-by of Cassini and landing of Huygens. They hence complement ideally the data gathered by this NASA/ESA mission, further optimising the overall scientific return. A group of astronomers [1] observed Titan with ESO's Very Large Telescope (VLT) at the Paranal Observatory (Chile) during the nights from 14 to 16 January, by means of the adaptive optics NAOS/CONICA instrument mounted on the 8.2-m Yepun telescope [2]. The observations were carried out in several modes, resulting in a series of fine images and detailed spectra of this mysterious moon. They complement earlier VLT observations of Titan, cf. ESO Press Photos 08/04 and ESO Press Release 09/04. The highest contrast images ESO PR Photo 04a/05 ESO PR Photo 04a/05 Titan's surface (NACO/VLT) [Preview - JPEG: 400 x 712 pix - 64k] [Normal - JPEG: 800 x 1424 pix - 524k] ESO PR Photo 04b/05 ESO PR Photo 04b/05 Map of Titan's Surface (NACO/VLT) [Preview - JPEG: 400 x 651 pix - 41k] [Normal - JPEG: 800 x 1301 pix - 432k] Caption: ESO PR Photo 04a/05 shows Titan's trailing hemisphere [3] with the Huygens landing site marked as an "X". The left image was taken with NACO and a narrow-band filter centred at 2 microns. On the right is the NACO/SDI image of the same location showing Titan's surface through the 1.6 micron methane window. A spherical projection with coordinates on Titan is overplotted. ESO PR Photo 04b/05 is a map of Titan taken with NACO at 1.28 micron (a methane window allowing it to probe down to the surface). On the leading side of Titan, the bright equatorial feature ("Xanadu") is dominating. On the trailing side, the landing site of the Huygens probe is indicated. ESO PR Photo 04c/05 ESO PR Photo 04c/05 Titan, the Enigmatic Moon, and Huygens Landing Site (NACO-SDI/VLT and Cassini/ISS) [Preview - JPEG: 400 x 589 pix - 40k] [Normal - JPEG: 800 x 1178 pix - 290k] Caption: ESO PR Photo 04c/05 is a comparison between the NACO/SDI image and an image taken by Cassini/ISS while approaching Titan. The Cassini image shows the Huygens landing site map wrapped around Titan, rotated to the same position as the January NACO SDI observations. The yellow "X" marks the landing site of the ESA Huygens probe. The Cassini/ISS image is courtesy of NASA, JPL, Space Science Institute (see http://sci.esa.int/science-e/www/object/index.cfm?fobjectid=36222). The coloured lines delineate the regions that were imaged by Cassini at differing resolutions. The lower-resolution imaging sequences are outlined in blue. Other areas have been specifically targeted for moderate and high resolution mosaicking of surface features. These include the site where the European Space Agency's Huygens probe has touched down in mid-January (marked with the yellow X), part of the bright region named Xanadu (easternmost extent of the area covered), and a boundary between dark and bright regions. ESO PR Photo 04d/05 ESO PR Photo 04d/05 Evolution of the Atmosphere of Titan (NACO/VLT) [Preview - JPEG: 400 x 902 pix - 40k] [Normal - JPEG: 800 x 1804 pix - 320k] Caption: ESO PR Photo 04d/05 is an image of Titan's atmosphere at 2.12 microns as observed with NACO on the VLT at three different epochs from 2002 till now. Titan's atmosphere exhibits seasonal and meteorological changes which can clearly be seen here : the North-South asymmetry - indicative of changes in the chemical composition in one pole or the other, depending on the season - is now clearly in favour of the North pole. Indeed, the situation has reversed with respect to a few years ago when the South pole was brighter. Also visible in these images is a bright feature in the South pole, found to be presently dimming after having appeared very bright from 2000 to 2003. The differences in size are due to the variation in the distance to Earth of Saturn and its planetary system. The new images show Titan's atmosphere and surface at various near-infrared spectral bands. The surface of Titan's trailing side is visible in images taken through narrow-band filters at wavelengths 1.28, 1.6 and 2.0 microns. They correspond to the so-called "methane windows" which allow to peer all the way through the lower Titan atmosphere to the surface. On the other hand, Titan's atmosphere is visible through filters centred in the wings of these methane bands, e.g. at 2.12 and 2.17 microns. Eric Gendron of the Paris Observatory in France and leader of the team, is extremely pleased: "We believe that some of these images are the highest-contrast images of Titan ever taken with any ground-based or earth-orbiting telescope." The excellent images of Titan's surface show the location of the Huygens landing site in much detail. In particular, those centred at wavelength 1.6 micron and obtained with the Simultaneous Differential Imager (SDI) on NACO [4] provide the highest contrast and best views. This is firstly because the filters match the 1.6 micron methane window most accurately. Secondly, it is possible to get an even clearer view of the surface by subtracting accurately the simultaneously recorded images of the atmospheric haze, taken at wavelength 1.625 micron. The images show the great complexity of Titan's trailing side, which was earlier thought to be very dark. However, it is now obvious that bright and dark regions cover the field of these images. The best resolution achieved on the surface features is about 0.039 arcsec, corresponding to 200 km on Titan. ESO PR Photo 04c/04 illustrates the striking agreement between the NACO/SDI image taken with the VLT from the ground and the ISS/Cassini map. The images of Titan's atmosphere at 2.12 microns show a still-bright south pole with an additional atmospheric bright feature, which may be clouds or some other meteorological phenomena. The astronomers have followed it since 2002 with NACO and notice that it seems to be fading with time. At 2.17 microns, this feature is not visible and the north-south asymmetry - also known as "Titan's smile" - is clearly in favour in the north. The two filters probe different altitude levels and the images thus provide information about the extent and evolution of the north-south asymmetry. Probing the composition of the surface ESO PR Photo 04e/05 ESO PR Photo 04e/05 Spectrum of Two Regions on Titan (NACO/VLT) [Preview - JPEG: 400 x 623 pix - 44k] [Normal - JPEG: 800 x 1246 pix - 283k] Caption: ESO PR Photo 04e/05 represents two of the many spectra obtained on January 16, 2005 with NACO and covering the 2.02 to 2.53 micron range. The blue spectrum corresponds to the brightest region on Titan's surface within the slit, while the red spectrum corresponds to the dark area around the Huygens landing site. In the methane band, the two spectra are equal, indicating a similar atmospheric content; in the methane window centred at 2.0 microns, the spectra show differences in brightness, but are in phase. This suggests that there is no real variation in the composition beyond different atmospheric mixings. ESO PR Photo 04f/05 ESO PR Photo 04f/05 Imaging Titan with a Tunable Filter (NACO Fabry-Perot/VLT) [Preview - JPEG: 400 x 718 pix - 44k] [Normal - JPEG: 800 x 1435 pix - 326k] Caption: ESO PR Photo 04f/05 presents a series of images of Titan taken around the 2.0 micron methane window probing different layers of the atmosphere and the surface. The images are currently under thorough processing and analysis so as to reveal any subtle variations in wavelength that could be indicative of the spectral response of the various surface components, thus allowing the astronomers to identify them. Because the astronomers have also obtained spectroscopic data at different wavelengths, they will be able to recover useful information on the surface composition. The Cassini/VIMS instrument explores Titan's surface in the infrared range and, being so close to this moon, it obtains spectra with a much better spatial resolution than what is possible with Earth-based telescopes. However, with NACO at the VLT, the astronomers have the advantage of observing Titan with considerably higher spectral resolution, and thus to gain more detailed spectral information about the composition, etc. The observations therefore complement each other. Once the composition of the surface at the location of the Huygens landing is known from the detailed analysis of the in-situ measurements, it should become possible to learn the nature of the surface features elsewhere on Titan by combining the Huygens results with more extended cartography from Cassini as well as from VLT observations to come. More information Results on Titan obtained with data from NACO/VLT are in press in the journal Icarus ("Maps of Titan's surface from 1 to 2.5 micron" by A. Coustenis et al.). Previous images of Titan obtained with NACO and with NACO/SDI are accessible as ESO PR Photos 08/04 and ESO PR Photos 11/04. See also these Press Releases for additional scientific references.
The Atacama Large Millimeter Array (ALMA)
NASA Astrophysics Data System (ADS)
1999-06-01
The Atacama Large Millimeter Array (ALMA) is the new name [2] for a giant millimeter-wavelength telescope project. As described in the accompanying joint press release by ESO and the U.S. National Science Foundation , the present design and development phase is now a Europe-U.S. collaboration, and may soon include Japan. ALMA may become the largest ground-based astronomy project of the next decade after VLT/VLTI, and one of the major new facilities for world astronomy. ALMA will make it possible to study the origins of galaxies, stars and planets. As presently envisaged, ALMA will be comprised of up to 64 12-meter diameter antennas distributed over an area 10 km across. ESO PR Photo 24a/99 shows an artist's concept of a portion of the array in a compact configuration. ESO PR Video Clip 03/99 illustrates how all the antennas will move in unison to point to a single astronomical object and follow it as it traverses the sky. In this way the combined telescope will produce astronomical images of great sharpness and sensitivity [3]. An exceptional site For such observations to be possible the atmosphere above the telescope must be transparent at millimeter and submillimeter wavelengths. This requires a site that is high and dry, and a high plateau in the Atacama desert of Chile, probably the world's driest, is ideal - the next best thing to outer space for these observations. ESO PR Photo 24b/99 shows the location of the chosen site at Chajnantor, at 5000 meters altitude and 60 kilometers east of the village of San Pedro de Atacama, as seen from the Space Shuttle during a servicing mission of the Hubble Space Telescope. ESO PR Photo 24c/99 and ESO PR Photo 24d/99 show a satellite image of the immediate vicinity and the site marked on a map of northern Chile. ALMA will be the highest continuously operated observatory in the world. The stark nature of this extreme site is well illustrated by the panoramic view in ESO PR Photo 24e/99. High sensitivity and sharp images ALMA will be extremely sensitive to radiation at milllimeter and submillimeter wavelengths. The large number of antennas gives a total collecting area of over 7000 square meters, larger than a football field. At the same time, the shape of the surface of each antenna must be extremely precise under all conditions; the overall accuracy over the entire 12-m diameter must be better than 0.025 millimeters (25µm), or one-third of the diameter of a human hair. The combination of large collecting area and high precision results in extremely high sensitivity to faint cosmic signals. The telescope must also be able to resolve the fine details of the objects it detects. In order to do this at millimeter wavelengths the effective diameter of the overall telescope must be very large - about 10 km. As it is impossible to build a single antenna with this diameter, an array of antennas is used instead, with the outermost antennas being 10 km apart. By combining the signals from all antennas together in a large central computer, it is possible to synthesize the effect of a single dish 10 km across. The resulting angular resolution is about 10 milli-arcseconds, less than one-thousandth the angular size of Saturn. Exciting research perspectives The scientific case for this revolutionary telescope is overwhelming. ALMA will make it possible to witness the formation of the earliest and most distant galaxies. It will also look deep into the dust-obscured regions where stars are born, to examine the details of star and planet formation. But ALMA will go far beyond these main science drivers, and will have a major impact on virtually all areas of astronomy. It will be a millimeter-wave counterpart to the most powerful optical/infrared telescopes such as ESO's Very Large Telescope (VLT) and the Hubble Space Telescope, with the additional advantage of being unhindered by cosmic dust opacity. The first galaxies in the Universe are expected to become rapidly enshrouded in the dust produced by the first stars. The dust can dim the galaxies at optical wavelengths, but the same dust radiates brightly at longer wavelengths. In addition, the expansion of the Universe causes the radiation from distant galaxies to be shifted to longer wavelengths. For both reasons, the earliest galaxies at the epoch of first light can be found with ALMA, and the subsequent evolution of galaxies can be mapped over cosmic time. ALMA will be of great importance for our understanding of the origins of stars and planetary systems. Stellar nurseries are completely obscured at optical wavelengths by dense "cocoons" of dust and gas, but ALMA can probe deep into these regions and study the fundamental processes by which stars are assembled. Moreover, it can observe the major reservoirs of biogenic elements (carbon, oxygen, nitrogen) and follow their incorporation into new planetary systems. A particularly exciting prospect for ALMA is to use its exceptionally sharp images to obtain evidence for planet formation by the presence of gaps in dusty disks around young stars, cleared by large bodies coalescing around the stars. Equally fundamental are observations of the dying gasps of stars at the other end of the stellar lifecycle, when they are often surrounded by shells of molecules and dust enriched in heavy elements produced by the nuclear fires now slowly dying. ALMA will offer exciting new views of our solar system. Studies of the molecular content of planetary atmospheres with ALMA's high resolving power will provide detailed weather maps of Mars, Jupiter, and the other planets and even their satellites. Studies of comets with ALMA will be particularly interesting. The molecular ices of these visitors from the outer reaches of the solar system have a composition that is preserved from ages when the solar system was forming. They evaporate when the comet comes close to the sun, and studies of the resulting gases with ALMA will allow accurate analysis of the chemistry of the presolar nebula. The road ahead The three-year design and development phase of the project is now underway as a collaboration between Europe and the U.S., and Japan may also join in this effort. Assuming the construction phase begins about two years from now, limited operations of the array may begin in 2005 and the full array may become operational by 2009. Notes [1] Press Releases about this event have also been issued by some of the other organisations participating in this project: * CNRS (in French) * MPG (in German) * NOVA (in Dutch) * NRAO * NSF (ASCII and HTML versions) * PPARC [2] "ALMA" means "soul" in Spanish. [3] Additional information about ALMA is available on the web: * Articles in the ESO Messenger - "The Large Southern Array" (March 1998), "European Site Testing at Chajnantor" (December 1998) and "The ALMA Project" (June 1999), cf. http://www.eso.org/gen-fac/pubs/messenger/ * ALMA website at ESO at http://www.eso.org/projects/alma/ * ALMA website at the U.S. National Radio Astronomy Observatory (NRAO) at http://www.mma.nrao.edu/ * ALMA website in The Netherlands about the detectors at http://www.sron.rug.nl/alma/ ALMA/Chajnantor Video Clip and Photos ESO PR Video Clip 03/99 [MPEG-version] ESO PR Video Clip 03/99 (2450 frames/1:38 min) [MPEG Video; 160x120 pix; 2.1Mb] [MPEG Video; 320x240 pix; 10.0Mb] [RealMedia; streaming; 700k] [RealMedia; streaming; 2.3M] About ESO Video Clip 03/99 : This video clip about the ALMA project contains two sequences. The first shows a panoramic scan of the Chajnantor plain from approx. north-east to north-west. The Chajnantor mountain passes through the field-of-view and the perfect cone of the Licancabur volcano (5900 m) on the Bolivian border is seen at the end (compare also with ESO PR 24e/99 below. The second is a 52-sec animation with a change of viewing perspective of the array and during which the antennas move in unison. For convenience, the clip is available in four versions: two MPEG files of different sizes and two streamer-versions of different quality that require RealPlayer software. There is no audio. Note that ESO Video News Reel No. 5 with more related scenes and in professional format with complete shot list is also available. ESO PR Photo 24b/99 ESO PR Photo 24b/99 [Preview - JPEG: 400 x 446 pix - 184k] [Normal - JPEG: 800 x 892 pix - 588k] [High-Res - JPEG: 3000 x 3345 pix - 5.4M] Caption to ESO PR Photo 24b/99 : View of Northern Chile, as seen from the NASA Space Shuttle during a servicing mission to the Hubble Space Telescope (partly visible to the left). The Atacama Desert, site of the ESO VLT at Paranal Observatory and the proposed location for ALMA at Chajnantor, is seen from North (foreground) to South. The two sites are only a few hundred km distant from each other. Few clouds are seen in this extremely dry area, due to the influence of the cold Humboldt Stream along the Chilean Pacific coast (right) and the high Andes mountains (left) that act as a barrier. Photo courtesy ESA astronaut Claude Nicollier. ESO PR Photo 24c/99 ESO PR Photo 24c/99 [Preview - JPEG: 400 x 318 pix - 212k] [Normal - JPEG: 800 x 635 pix - 700k] [High-Res - JPEG: 3000 x 2382 pix - 5.9M] Caption to ESO PR Photo 24c/99 : This satellite image of the Chajnantor area was produced in 1998 at Cornell University (USA), by Jennifer Yu, Jeremy Darling and Riccardo Giovanelli, using the Thematic Mapper data base maintained at the Geology Department laboratory directed by Bryan Isacks. It is a composite of three exposures in spectral bands at 1.6 µm (rendered as red), 1.0 µm (green) and 0.5 µm (blue). The horizontal resolution of the false-colour image is about 30 meters. North is at the top of the photo. ESO PR Photo 24d/99 ESO PR Photo 24d/99 [Preview - JPEG: 400 x 381 pix - 108k] [Normal - JPEG: 800 x 762 pix - 240k] [High-Res - JPEG: 2300 x 2191 pix - 984k] Caption to ESO PR Photo 24d/99 : Geographical map with the sites of the VLT and ALMA indicated. ESO PR Photo 24e/99 ESO PR Photo 24e/99 [Preview - JPEG: 400 x 238 pix - 93k] [Normal - JPEG: 800 x 475 pix - 279k] [High-Res - JPEG: 2862 x 1701 pix - 4.2M] Caption to ESO PR Photo 24e/99 : Panoramic view of the proposed site for ALMA at Chajnantor. This high-altitude plain (elevation 5000 m) in the Chilean Andes mountains is an ideal site for ALMA. In this view towards the north, the Chajnantor mountain (5600 m) is in the foreground, left of the centre. The perfect cone of the Licancabur volcano (5900 m) on the Bolivian border is in the background further to the left. This image is a wide-angle composite (140° x 70°) of three photos (Hasselblad 6x6 with SWC 1:4.5/38 mm Biogon), obtained in December 1998. How to obtain ESO Press Information ESO Press Information is made available on the World-Wide Web (URL: http://www.eso.org../ ). ESO Press Photos may be reproduced, if credit is given to the European Southern Observatory.
Chowdhary, Ramesh; Halldin, Anders; Jimbo, Ryo; Wennerberg, Ann
2015-06-01
To describe the early bone tissue response to implants with and without micro threads designed to the full length of an oxidized titanium implant. A pair of two-dimensional finite element models was designed using a computer aided three-dimensional interactive application files of an implant model with micro threads in between macro threads and one without micro threads. Oxidized titanium implants with (test implants n=20) and without (control implants n=20) micro thread were prepared. A total of 12 rabbits were used and each received four implants. Insertion torque while implant placement and removal torque analysis after 4 weeks was performed in nine rabbits, and histomorphometric analysis in three rabbits, respectively. Finite element analysis showed less stress accumulation in test implant models with 31Mpa when compared with 62.2 Mpa in control implant model. Insertion and removal torque analysis did not show any statistical significance between the two implant designs. At 4 weeks, there was a significant difference between the two groups in the percentage of new bone volume and bone-to-implant contact in the femur (p< .05); however, not in the tibia. The effect of micro threads was prominent in the femur suggesting that micro threads promote bone formation. The stress distribution supported by the micro threads was especially effective in the cancellous bone. © 2013 Wiley Periodicals, Inc.
Influence of peri-implant artifacts on bone morphometric analysis with micro-computed tomography.
Song, Jin Wook; Cha, Jung Yul; Bechtold, Till Edward; Park, Young Chel
2013-01-01
To determine the optimal dilation pixel size distance from the mini-implant interface needed to compensate for the metal artifact on micro-computed tomography (micro-CT) for bone morphometric analysis. A total of 72 self-drilling mini-implants were placed into the buccal alveolar bone of six male beagle dogs. After 12 weeks of orthodontic loading, specimens were harvested and scanned with micro-CT (Skyscan 1076) at a resolution of 9 μm. Using the reload plug-in and dilation procedure of CTAn, the percentage of bone-implant contact (BIC) and bone volume density (BV/TV, bone volume/total volume), respectively, were measured from one to seven pixels from the metal implant surface. Each pixel size of dilation (PSD) were compared with that of a ground histologic section, and the optimal PSD for bone morphometric analysis using micro-CT was determined. BIC values from micro-CT analysis decreased when the PSD increased (P < .05). BIC from micro-CT showed the highest correlation coefficient with BIC from histologic slides when the PSD was 5 to 7 (P < .05), whereas BV/TV from micro-CT showed a very high correlation with BV/TV from histologic slides in all ranges (P < .0001). To measure BIC and BV/TV using micro-CT, at least 5 PSD from the metal implant surface is needed.
Wyatt, S K; Barck, K H; Kates, L; Zavala-Solorio, J; Ross, J; Kolumam, G; Sonoda, J; Carano, R A D
2015-11-01
The ability to non-invasively measure body composition in mouse models of obesity and obesity-related disorders is essential for elucidating mechanisms of metabolic regulation and monitoring the effects of novel treatments. These studies aimed to develop a fully automated, high-throughput micro-computed tomography (micro-CT)-based image analysis technique for longitudinal quantitation of adipose, non-adipose and lean tissue as well as bone and demonstrate utility for assessing the effects of two distinct treatments. An initial validation study was performed in diet-induced obesity (DIO) and control mice on a vivaCT 75 micro-CT system. Subsequently, four groups of DIO mice were imaged pre- and post-treatment with an experimental agonistic antibody specific for anti-fibroblast growth factor receptor 1 (anti-FGFR1, R1MAb1), control immunoglobulin G antibody, a known anorectic antiobesity drug (rimonabant, SR141716), or solvent control. The body composition analysis technique was then ported to a faster micro-CT system (CT120) to markedly increase throughput as well as to evaluate the use of micro-CT image intensity for hepatic lipid content in DIO and control mice. Ex vivo chemical analysis and colorimetric analysis of the liver triglycerides were performed as the standard metrics for correlation with body composition and hepatic lipid status, respectively. Micro-CT-based body composition measures correlate with ex vivo chemical analysis metrics and enable distinction between DIO and control mice. R1MAb1 and rimonabant have differing effects on body composition as assessed by micro-CT. High-throughput body composition imaging is possible using a modified CT120 system. Micro-CT also provides a non-invasive assessment of hepatic lipid content. This work describes, validates and demonstrates utility of a fully automated image analysis technique to quantify in vivo micro-CT-derived measures of adipose, non-adipose and lean tissue, as well as bone. These body composition metrics highly correlate with standard ex vivo chemical analysis and enable longitudinal evaluation of body composition and therapeutic efficacy monitoring.
ERIC Educational Resources Information Center
Balajthy, Ernest; Reuber, Kristin; Damon, Corrine J.
A study investigated software choices of graduate-level clinicians in a university reading clinic to determine computer use and effectiveness in literacy instruction. The clinic involved students of varying ability, ages 7-12, using 24 Power Macintosh computers equipped with "ClarisWorks,""Kid Pix,""Student Writing…
looking east.jpg 183 KB UNIS Ion Source 111 KB MP-7 Low Energy.jpg 138 KB MP-7 Object West.jpg 117 KB MP-7 Object Middle.jpg 120 KB MP-7 Object East.jpg 142 KB MP-7 Image.jpg 151 KB SEU area in TR-4 looking
Environmentally-induced discharge transient coupling to spacecraft
NASA Technical Reports Server (NTRS)
Viswanathan, R.; Barbay, G.; Stevens, N. J.
1985-01-01
The Hughes SCREENS (Space Craft Response to Environments of Space) technique was applied to generic spin and 3-axis stabilized spacecraft models. It involved the NASCAP modeling for surface charging and lumped element modeling for transients coupling into a spacecraft. A differential voltage between antenna and spun shelf of approx. 400 V and current of 12 A resulted from discharge at antenna for the spinner and approx. 3 kv and 0.3 A from a discharge at solar panels for the 3-axis stabilized Spacecraft. A typical interface circuit response was analyzed to show that the transients would couple into the Spacecraft System through ground points, which are most vulnerable. A compilation and review was performed on 15 years of available data from electron and ion current collection phenomena. Empirical models were developed to match data and compared with flight data of Pix-1 and Pix-2 mission. It was found that large space power systems would float negative and discharge if operated at or above 300 V. Several recommendations are given to improve the models and to apply them to large space systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Elander, N.; Oddershede, J.; Beebe, N.H.F.
1977-08-15
Polarization propagator calculation of spectroscopic constants and radiative lifetimes for the A /sup 1/Pi--X /sup 1/..sigma../sup +/ band system are presented. The spectroscopic constants agree well with experimental and other theoretical values. We have also performed an iterative Rydberg-Klein-Rees (RKR) calculation of B/sub e/, ..omega../sub e/, and ..omega../sub e/x/sub e/ for the experimental X /sup 1/..sigma../sup +/ state.The calculated radiative lifetime for the A /sup 1/Pi state (v'=0) is 660 ns and 598 ns, with theoretical and experimental potential energy curves, respectively. This difference (about 60 ns) indicates the inaccuracy in the present calculation. Experimentally the most recent estimate ofmore » the A /sup 1/Pi (v'=0) state is 630 +- 50 ns, and theoretically the Yoshimine et al. transition moment gives tau (A /sup 1/Pi, v'=0) =722 ns.The radiative lifetimes calculated for CD/sup +/ are between 1.3% and 3.9% larger than the corresponding CH/sup +/ lifetimes.« less
NASA Astrophysics Data System (ADS)
Pappalardo, L.; Karydas, A. G.; Kotzamani, N.; Pappalardo, G.; Romano, F. P.; Zarkadas, Ch.
2005-09-01
Gemstones on gold Hellenistic (late 4th century BC, 1st AD) jewelry, exhibited at the Benaki Museum of Athens, were analyzed in situ by means of two non-destructive and portable analytical techniques. The composition of major and minor elements was determined using a new portable PIXE-alpha spectrometer. The analytical features of this spectrometer allow the determination of matrix elements from Na to Zn through the K-lines and the determination of higher atomic number elements via the L- or M-lines. The red stones analyzed were revealed as red garnets, displaying a compositional range from Mg-rich garnet to Fe-rich garnet. The complementary use of a portable XRF spectrometer provided additional information on some trace elements (Cr and Y), which are considered to be important for the chemical separation between different garnet groups. A comparison of our results with recent literature data offers useful indications about the possible geographical provenance of the stones. The analytical techniques, their complementarity and the results obtained are presented and discussed.
Development Of PIXE Measurement Of Ca Changes Resulting From Viral Transduction In Cells
NASA Astrophysics Data System (ADS)
Whitlow, Harry J.; Chienthavorn, Orapin; Eronen, Hannele; Sajavaara, Timo; Laitinen, Mikko; Norarat, Rattanaporn; Gilbert, Leona K.
2011-06-01
Ca is a life-element of particular interest because it is both bound to proteins, and as Ca2+ which functions as a signal molecule in apoptosis. Here we report development of chemical-matrix blind assaying the Ca fluxes from transduced HepG2 cells using particle induced X-ray emission. The cells were transduced with recombinant baculoviruses hosting the DNA for non-structural protein 1 (NS1) of the human pavovirus B19. Different recombinant baculoviruses were used that carried different DNA payloads of this NS1. Two different approaches have been developed to assay Ca in cells. The first is where the cells were directly cultured using a self-supporting pioloform as a substrate. In the second approach the cells are permeabilized, and bound-Ca content in the debris, and unbound-Ca in the wash solutions were measured using an internal V reference standard. The results support a difference in the Ca contents depending on the payload of the infecting virus, however the PIXE signals were too close to the minimum detection limit to draw reliable conclusions.
NASA Astrophysics Data System (ADS)
2004-12-01
On December 9-10, 2004, the ESO Paranal Observatory was honoured with an overnight visit by His Excellency the President of the Republic of Chile, Ricardo Lagos and his wife, Mrs. Luisa Duran de Lagos. The high guests were welcomed by the ESO Director General, Dr. Catherine Cesarsky, ESO's representative in Chile, Mr. Daniel Hofstadt, and Prof. Maria Teresa Ruiz, Head of the Astronomy Department at the Universidad de Chile, as well as numerous ESO staff members working at the VLT site. The visit was characterised as private, and the President spent a considerable time in pleasant company with the Paranal staff, talking with and getting explanations from everybody. The distinguished visitors were shown the various high-tech installations at the observatory, including the Interferometric Tunnel with the VLTI delay lines and the first Auxiliary Telescope. Explanations were given by ESO astronomers and engineers and the President, a keen amateur astronomer, gained a good impression of the wide range of exciting research programmes that are carried out with the VLT. President Lagos showed a deep interest and impressed everyone present with many, highly relevant questions. Having enjoyed the spectacular sunset over the Pacific Ocean from the Residence terrace, the President met informally with the Paranal employees who had gathered for this unique occasion. Later, President Lagos visited the VLT Control Room from where the four 8.2-m Unit Telescopes and the VLT Interferometer (VLTI) are operated. Here, the President took part in an observing sequence of the spiral galaxy NGC 1097 (see PR Photo 35d/04) from the console of the MELIPAL telescope. After one more visit to the telescope platform at the top of Paranal, the President and his wife left the Observatory in the morning of December 10, 2004, flying back to Santiago. ESO PR Photo 35e/04 ESO PR Photo 35e/04 President Lagos Meets with ESO Staff at the Paranal Residencia [Preview - JPEG: 400 x 267pix - 144k] [Normal - JPEG: 640 x 427 pix - 240k] ESO PR Photo 35f/04 ESO PR Photo 35f/04 The Presidential Couple with Professor Maria Teresa Ruiz and the ESO Director General [Preview - JPEG: 500 x 400 pix - 224k] [Normal - JPEG: 1000 x 800 pix - 656k] [FullRes - JPEG: 1575 x 1260 pix - 1.0M] ESO PR Photo 35g/04 ESO PR Photo 35g/04 President Lagos with ESO Staff [Preview - JPEG: 500 x 400 pix - 192k] [Normal - JPEG: 1000 x 800 pix - 592k] [FullRes - JPEG: 1575 x 1200 pix - 1.1M] Captions: ESO PR Photo 35e/04 was obtained during President Lagos' meeting with ESO Staff at the Paranal Residencia. On ESO PR Photo 35f/04, President Lagos and Mrs. Luisa Duran de Lagos are seen at a quiet moment during the visit to the VLT Control Room, together with Prof. Maria Teresa Ruiz (far right), Head of the Astronomy Department at the Universidad de Chile, and the ESO Director General. ESO PR Photo 35g/04 shows President Lagos with some ESO staff members in the Paranal Residencia. VLT obtains a splendid photo of a unique galaxy, NGC 1097 ESO PR Photo 35d/04 ESO PR Photo 35d/04 Spiral Galaxy NGC 1097 (Melipal + VIMOS) [Preview - JPEG: 400 x 525 pix - 181k] [Normal - JPEG: 800 x 1049 pix - 757k] [FullRes - JPEG: 2296 x 3012 pix - 7.9M] Captions: ESO PR Photo 35d/04 is an almost-true colour composite based on three images made with the multi-mode VIMOS instrument on the 8.2-m Melipal (Unit Telescope 3) of ESO's Very Large Telescope. They were taken on the night of December 9-10, 2004, in the presence of the President of the Republic of Chile, Ricardo Lagos. Details are available in the Technical Note below. A unique and very beautiful image was obtained with the VIMOS instrument with President Lagos at the control desk. Located at a distance of about 45 million light-years in the southern constellation Fornax (the Furnace), NGC 1097 is a relatively bright, barred spiral galaxy of type SBb, seen face-on. At magnitude 9.5, and thus just 25 times fainter than the faintest object that can be seen with the unaided eye, it appears in small telescopes as a bright, circular disc. ESO PR Photo 35d/04, taken on the night of December 9 to 10, 2004 with the VIsible Multi-Object Spectrograph ("VIMOS), a four-channel multiobject spectrograph and imager attached to the 8.2-m VLT Melipal telescope, shows that the real structure is much more complicated. NGC 1097 is indeed a most interesting object in many respects. As this striking image reveals, NGC 1097 presents a centre that consists of a broken ring of bright knots surrounding the galaxy's nucleus. The sizes of these knots - presumably gigantic bubbles of hydrogen atoms having lost one electron (HII regions) through the intense radiation from luminous massive stars - range from roughly 750 to 2000 light-years. The presence of these knots suggests that an energetic burst of star formation has recently occurred. NGC 1097 is also known as an example of the so-called LINER (Low-Ionization Nuclear Emission Region Galaxies) class. Objects of this type are believed to be low-luminosity examples of Active Galactic Nuclei (AGN), whose emission is thought to arise from matter (gas and stars) falling into oblivion in a central black hole. There is indeed much evidence that a supermassive black hole is located at the very centre of NGC 1097, with a mass of several tens of million times the mass of the Sun. This is at least ten times more massive than the central black hole in our own Milky Way. However, NGC 1097 possesses a comparatively faint nucleus only, and the black hole in its centre must be on a very strict "diet": only a small amount of gas and stars is apparently being swallowed by the black hole at any given moment. A turbulent past As can be clearly seen in the upper part of PR Photo 35d/04, NGC 1097 also has a small galaxy companion; it is designated NGC 1097A and is located about 42,000 light-years away from the centre of NGC 1097. This peculiar elliptical galaxy is 25 times fainter than its big brother and has a "box-like" shape, not unlike NGC 6771, the smallest of the three galaxies that make up the famous Devil's Mask, cf. ESO PR Photo 12/04. There is evidence that NGC 1097 and NGC 1097A have been interacting in the recent past. Another piece of evidence for this galaxy's tumultuous past is the presence of four jets - not visible on this image - discovered in the 1970's on photographic plates. These jets are now believed to be the captured remains of a disrupted dwarf galaxy that passed through the inner part of the disc of NGC 1097. Moreover, another interesting feature of this active galaxy is the fact that no less than two supernovae were detected inside it within a time span of only four years. SN 1999eu was discovered by Japanese amateur Masakatsu Aoki (Toyama, Japan) on November 5, 1999. This 17th-magnitude supernova was a peculiar Type II supernova, the end result of the core collapse of a very massive star. And in the night of January 5 to 6, 2003, Reverend Robert Evans (Australia) discovered another Type II supernova of 15th magnitude. Also visible in this very nice image which was taken during very good sky conditions - the seeing was well below 1 arcsec - are a multitude of background galaxies of different colours and shapes. Given the fact that the total exposure time for this three-colour image was just 11 min, it is a remarkable feat, demonstrating once again the very high efficiency of the VLT.
Pendleton, Michael W; Washburn, Dorothy K; Ellis, E Ann; Pendleton, Bonnie B
2014-03-01
The same sherd was analyzed using a scanning electron microscope with energy dispersive spectroscopy (SEM-EDS) and a micro X-ray fluorescence tube attached to a scanning electron microscope (Micro-XRF-SEM) to compare the effectiveness of elemental detection of iron-based pigment. To enhance SEM-EDS mapping, the sherd was carbon coated. The carbon coating was not required to produce Micro-XRF-SEM maps but was applied to maintain an unbiased comparison between the systems. The Micro-XRF-SEM analysis was capable of lower limits of detection than that of the SEM-EDS system, and therefore the Micro-XRF-SEM system could produce elemental maps of elements not easily detected by SEM-EDS mapping systems. Because SEM-EDS and Micro-XRF-SEM have been used for imaging and chemical analysis of biological samples, this comparison of the detection systems should be useful to biologists, especially those involved in bone or tooth (hard tissue) analysis.
Pendleton, Michael W.; Washburn, Dorothy K.; Ellis, E. Ann; Pendleton, Bonnie B.
2014-01-01
The same sherd was analyzed using a scanning electron microscope with energy dispersive spectroscopy (SEM-EDS) and a micro X-ray fluorescence tube attached to a scanning electron microscope (Micro-XRF-SEM) to compare the effectiveness of elemental detection of iron-based pigment. To enhance SEM-EDS mapping, the sherd was carbon coated. The carbon coating was not required to produce Micro-XRF-SEM maps but was applied to maintain an unbiased comparison between the systems. The Micro-XRF-SEM analysis was capable of lower limits of detection than that of the SEM-EDS system, and therefore the Micro-XRF-SEM system could produce elemental maps of elements not easily detected by SEM-EDS mapping systems. Because SEM-EDS and Micro-XRF-SEM have been used for imaging and chemical analysis of biological samples, this comparison of the detection systems should be useful to biologists, especially those involved in bone or tooth (hard tissue) analysis. PMID:24600333
ESO and NSF Sign Agreement on ALMA
NASA Astrophysics Data System (ADS)
2003-02-01
Green Light for World's Most Powerful Radio Observatory On February 25, 2003, the European Southern Observatory (ESO) and the US National Science Foundation (NSF) are signing a historic agreement to construct and operate the world's largest and most powerful radio telescope, operating at millimeter and sub-millimeter wavelength. The Director General of ESO, Dr. Catherine Cesarsky, and the Director of the NSF, Dr. Rita Colwell, act for their respective organizations. Known as the Atacama Large Millimeter Array (ALMA), the future facility will encompass sixty-four interconnected 12-meter antennae at a unique, high-altitude site at Chajnantor in the Atacama region of northern Chile. ALMA is a joint project between Europe and North America. In Europe, ESO is leading on behalf of its ten member countries and Spain. In North America, the NSF also acts for the National Research Council of Canada and executes the project through the National Radio Astronomy Observatory (NRAO) operated by Associated Universities, Inc. (AUI). The conclusion of the ESO-NSF Agreement now gives the final green light for the ALMA project. The total cost of approximately 650 million Euro (or US Dollars) is shared equally between the two partners. Dr. Cesarsky is excited: "This agreement signifies the start of a great project of contemporary astronomy and astrophysics. Representing Europe, and in collaboration with many laboratories and institutes on this continent, we together look forward towards wonderful research projects. With ALMA we may learn how the earliest galaxies in the Universe really looked like, to mention but one of the many eagerly awaited opportunities with this marvellous facility". "With this agreement, we usher in a new age of research in astronomy" says Dr. Colwell. "By working together in this truly global partnership, the international astronomy community will be able to ensure the research capabilities needed to meet the long-term demands of our scientific enterprise, and that we will be able to study and understand our universe in ways that have previously been beyond our vision". The recent Presidential decree from Chile for AUI and the agreement signed in late 2002 between ESO and the Government of the Republic of Chile (cf. ESO PR 18/02) recognize the interest that the ALMA Project has for Chile, as it will deepen and strengthen the cooperation in scientific and technological matters between the parties. A joint ALMA Board has been established which oversees the realisation of the ALMA project via the management structure. This Board meets for the first time on February 24-25, 2003, at NSF in Washington and will witness this historic event. ALMA: Imaging the Light from Cosmic Dawn ESO PR Photo 06a/03 ESO PR Photo 06a/03 [Preview - JPEG: 588 x 400 pix - 52k [Normal - JPEG: 1176 x 800 pix - 192k] [Hi-Res - JPEG: 3300 x 2244 pix - 2.0M] ESO PR Photo 06b/03 ESO PR Photo 06b/03 [Preview - JPEG: 502 x 400 pix - 82k [Normal - JPEG: 1003 x 800 pix - 392k] [Hi-Res - JPEG: 2222 x 1773 pix - 3.0M] ESO PR Photo 06c/03 ESO PR Photo 06c/03 [Preview - JPEG: 474 x 400 pix - 84k [Normal - JPEG: 947 x 800 pix - 344k] [Hi-Res - JPEG: 2272 x 1920 pix - 2.0M] ESO PR Photo 06d/03 ESO PR Photo 06d/03 [Preview - JPEG: 414 x 400 pix - 69k [Normal - JPEG: 828 x 800 pix - 336k] [HiRes - JPEG: 2935 x 2835 pix - 7.4k] Captions: PR Photo 06a/03 shows an artist's view of the Atacama Large Millimeter Array (ALMA), with 64 12-m antennae. PR Photo 06b/03 is another such view, with the array arranged in a compact configuration at the high-altitude Chajnantor site. The ALMA VertexRSI prototype antennae is shown in PR Photo 06c/03 on the Antenna Test Facility (ATF) site at the NRAO Very Large Array (VLA) site near Socorro (New Mexico, USA). The future ALMA site at Llano de Chajnantor at 5000 metre altitude, some 40 km East of the village of San Pedro de Atacama (Chile) is seen in PR Photo 06d/03 - this view was obtained at 11 hrs in the morning on a crisp and clear autumn day (more views of this site are available at the Chajnantor Photo Gallery). The Atacama Large Millimeter Array (ALMA) will be one of astronomy's most powerful telescopes - providing unprecedented imaging capabilities and sensitivity in the corresponding wavelength range, many orders of magnitude greater than anything of its kind today. ALMA will be an array of 64 antennae that will work together as one telescope to study millimeter and sub-millimeter wavelength radiation from space. This radiation crosses the critical boundary between infrared and microwave radiation and holds the key to understanding such processes as planet and star formation, the formation of early galaxies and galaxy clusters, and the formation of organic and other molecules in space. "ALMA will be one of astronomy's premier tools for studying the universe" says Nobel Laureate Riccardo Giacconi, President of AUI (and former ESO Director General (1993-1999)). "The entire astronomical community is anxious to have the unprecedented power and resolution that ALMA will provide". The President of the ESO Council, Professor Piet van der Kruit, agrees: "ALMA heralds a break-through in sub-millimeter and millimeter astronomy, allowing some of the most penetrating studies the Universe ever made. It is safe to predict that there will be exciting scientific surprises when ALMA enters into operation". What is millimeter and sub-millimeter wavelength astronomy? Astronomers learn about objects in space by studying the energy emitted by those objects. Our Sun and the other stars throughout the Universe emit visible light. But these objects also emit other kinds of light waves, such as X-rays, infrared radiation, and radio waves. Some objects emit very little or no visible light, yet are strong sources at other wavelengths in the electromagnetic spectrum. Much of the energy in the Universe is present in the sub-millimeter and millimeter portion of the spectrum. This energy comes from the cold dust mixed with gas in interstellar space. It also comes from distant galaxies that formed many billions of years ago at the edges of the known universe. With ALMA, astronomers will have a uniquely powerful facility with access to this remarkable portion of the spectrum and hence, new and wonderful opportunities to learn more about those objects. Current observatories simply do not have anywhere near the necessary sensitivity and resolution to unlock the secrets that abundant sub-millimeter and millimeter wavelength radiation can reveal. It will take the unparalleled power of ALMA to fully study the cosmic emission at this wavelength and better understand the nature of the universe. Scientists from all over the world will use ALMA. They will compete for observing time by submitting proposals, which will be judged by a group of their peers on the basis of scientific merit. ALMA's unique capabilities ALMA's ability to detect remarkably faint sub-millimeter and millimeter wavelength emission and to create high-resolution images of the source of that emission gives it capabilities not found in any other astronomical instruments. ALMA will therefore be able to study phenomena previously out of reach to astronomers and astrophysicists, such as: * Very young galaxies forming stars at the earliest times in cosmic history; * New planets forming around young stars in our galaxy, the Milky Way; * The birth of new stars in spinning clouds of gas and dust; and * Interstellar clouds of gas and dust that are the nurseries of complex molecules and even organic chemicals that form the building blocks of life. How will ALMA work? All of ALMA's 64 antennae will work in concert, taking quick "snapshots" or long-term exposures of astronomical objects. Cosmic radiation from these objects will be reflected from the surface of each antenna and focussed onto highly sensitive receivers cooled to just a few degrees above absolute zero in order to suppress undesired "noise" from the surroundings. There the signals will be amplified many times, digitized, and then sent along underground fiber-optic cables to a large signal processor in the central control building. This specialized computer, called a correlator - running at 16,000 million-million operations per second - will combine all of the data from the 64 antennae to make images of remarkable quality. The extraordinary ALMA site Since atmospheric water vapor absorbs millimeter and (especially) sub-millimeter waves, ALMA must be constructed at a very high altitude in a very dry region of the earth. Extensive tests showed that the sky above the Atacama Desert of Chile has the excellent clarity and stability essential for ALMA. That is why ALMA will be built there, on Llano de Chajnantor at an altitude of 5,000 metres in the Chilean Andes. A series of views of this site, also in high-resolution suitable for reproduction, is available at the Chajnantor Photo Gallery. Timeline for ALMA June 1998: Phase 1 (Research and Development) June 1999: European/American Memorandum of Understanding February 2003: Signature of the bilateral Agreement 2004: Tests of the Prototype System 2007: Initial scientific operation of a partially completed array 2011: End of construction of the array
The initial design of LAPAN's IR micro bolometer using mission analysis process
NASA Astrophysics Data System (ADS)
Bustanul, A.; Irwan, P.; M. T., Andi; Firman, B.
2016-11-01
As new player in Infra Red (IR) sector, uncooled, small, and lightweight IR Micro Bolometer has been chosen as one of payloads for LAPAN's next micro satellite project. Driven the desire to create our own IR Micro Bolometer, mission analysis design procedure has been applied. After tracing all possible missions, the Planck's and Wien's Law for black body, Temperature Responsivity (TR), and sub-pixel response had been utilized in order to determine the appropriate spectral radiance. The 3.8 - 4 μm wavelength were available to detect wild fire (forest fire) and active volcanoes, two major problems faced by Indonesia. In order to strengthen and broaden the result, iteration process had been used throughout the process. The analysis, then, were continued by calculating Ground pixel size, IFOV pixel, swath width, and focus length. Meanwhile, regarding of resolution, at least it is 400 m. The further procedure covered the integrated of optical design, wherein we combined among optical design software, Zemax, with mechanical analysis software (structure and thermal analysis), such as Nastran and Thermal Desktop / Sinda Fluint. The integration process was intended to produce high performance optical system of our IR Micro Bolometer that can be used under extreme environment. The results of all those analysis, either in graphs or in measurement, show that the initial design of LAPAN'S IR Micro Bolometer meets the determined requirement. However, it needs the further evaluation (iteration). This paper describes the initial design of LAPAN's IR Micro Bolometer using mission analysis process
The HRSC Experiment on Mars Express: First Imaging Results from the Commissioning Phase
NASA Astrophysics Data System (ADS)
Oberst, J.; Neukum, G.; Hoffmann, H.; Jaumann, R.; Hauber, E.; Albertz, J.; McCord, T. B.; Markiewicz, W. J.
2004-12-01
The ESA Mars Express spacecraft was launched from Baikonur on June 2, 2003, entered Mars orbit on December 25, 2003, and reached the nominal mapping orbit on January 28, 2004. Observing conditions were favorable early on for the HRSC (High Resolution Stereo Camera), designed for the mapping of the Martian surface in 3-D. The HRSC is a pushbroom scanner with 9 CCD line detectors mounted in parallel and perpendicular to the direction of flight on the focal plane. The camera can obtain images at high resolution (10 m/pix), in triple stereo (20 m/pix), in four colors, and at five different phase angles near-simultaneously. An additional Super-Resolution Channel (SRC) yields nested-in images at 2.3 m/pix for detailed photogeologic studies. Even for nominal spacecraft trajectory and camera pointing data from the commissioning phase, solid stereo image reconstructions are feasible. More yet, the three-line stereo data allow us to identify and correct errors in navigation data. We find that > 99% of the stereo rays intersect within a sphere of radius < 20m after orbit and pointing data correction. From the HRSC images we have produced Digital Terrain Models (DTMs) with pixel sizes of 200 m, some of them better. HRSC stereo models and data obtained by the MOLA (Mars Orbiting Laser Altimeter) show good qualitative agreement. Differences in absolute elevations are within 50 m, but may reach several 100 m in lateral positioning (mostly in the spacecraft along-track direction). After correction of these offsets, the HRSC topographic data conveniently fill the gaps between the MOLA tracks and reveal hitherto unrecognized morphologic detail. At the time of writing, the HRSC has covered approx. 22.5 million square kilometers of the Martian surface. In addition, data from 5 Phobos flybys from May through August 2004 were obtained. The HRSC is beginning to make major contributions to geoscience, atmospheric science, photogrammetry, and cartography of Mars (papers submitted to Nature).
VLTI First Fringes with Two Auxiliary Telescopes at Paranal
NASA Astrophysics Data System (ADS)
2005-03-01
World's Largest Interferometer with Moving Optical Telescopes on Track Summary The Very Large Telescope Interferometer (VLTI) at Paranal Observatory has just seen another extension of its already impressive capabilities by combining interferometrically the light from two relocatable 1.8-m Auxiliary Telescopes. Following the installation of the first Auxiliary Telescope (AT) in January 2004 (see ESO PR 01/04), the second AT arrived at the VLT platform by the end of 2004. Shortly thereafter, during the night of February 2 to 3, 2005, the two high-tech telescopes teamed up and quickly succeeded in performing interferometric observations. This achievement heralds an era of new scientific discoveries. Both Auxiliary Telescopes will be offered from October 1, 2005 to the community of astronomers for routine observations, together with the MIDI instrument. By the end of 2006, Paranal will be home to four operational ATs that may be placed at 30 different positions and thus be combined in a very large number of ways ("baselines"). This will enable the VLTI to operate with enormous flexibility and, in particular, to obtain extremely detailed (sharp) images of celestial objects - ultimately with a resolution that corresponds to detecting an astronaut on the Moon. PR Photo 07a/05: Paranal Observing Platform with AT1 and AT2 PR Photo 07b/05: AT1 and AT2 with Open Domes PR Photo 07c/05: Evening at Paranal with AT1 and AT2 PR Photo 07d/05: AT1 and AT2 under the Southern Sky PR Photo 07e/05: First Fringes with AT1 and AT2 PR Video Clip 01/05: Two ATs at Paranal (Extract from ESO Newsreel 15) A Most Advanced Device ESO PR Video 01/05 ESO PR Video 01/05 Two Auxiliary Telescopes at Paranal [QuickTime: 160 x 120 pix - 37Mb - 4:30 min] [QuickTime: 320 x 240 pix - 64Mb - 4:30 min] ESO PR Photo 07a/05 ESO PR Photo 07a/05 [Preview - JPEG: 493 x400 pix - 44k] [Normal - JPEG: 985 x 800 pix - 727k] [HiRes - JPEG: 5000 x 4060 pix - 13.8M] Captions: ESO PR Video Clip 01/05 is an extract from ESO Video Newsreel 15, released on March 14, 2005. It provides an introduction to the VLT Interferometer (VLTI) and the two Auxiliary Telescopes (ATs) now installed at Paranal. ESO PR Photo 07a/05 shows the impressive ensemble at the summit of Paranal. From left to right, the enclosure of VLT Antu, Kueyen and Melipal, AT1, the VLT Survey Telescope (VST) in the background, AT2 and VLT Yepun. Located at the summit of the 2,600-m high Cerro Paranal in the Atacama Desert (Chile), ESO's Very Large Telescope (VLT) is at the forefront of astronomical technology and is one of the premier facilities in the world for optical and near-infrared observations. The VLT is composed of four 8.2-m Unit Telescope (Antu, Kueyen, Melipal and Yepun). They have been progressively put into service together with a vast suite of the most advanced astronomical instruments and are operated every night in the year. Contrary to other large astronomical telescopes, the VLT was designed from the beginning with the use of interferometry as a major goal. The href="/instruments/vlti">VLT Interferometer (VLTI) combines starlight captured by two 8.2- VLT Unit Telescopes, dramatically increasing the spatial resolution and showing fine details of a large variety of celestial objects. The VLTI is arguably the world's most advanced optical device of this type. It has already demonstrated its powerful capabilities by addressing several key scientific issues, such as determining the size and the shape of a variety of stars (ESO PR 22/02, PR 14/03 and PR 31/03), measuring distances to stars (ESO PR 25/04), probing the innermost regions of the proto-planetary discs around young stars (ESO PR 27/04) or making the first detection by infrared interferometry of an extragalactic object (ESO PR 17/03). "Little Brothers" ESO PR Photo 07b/05 ESO PR Photo 07b/05 [Preview - JPEG: 597 x 400 pix - 47k] [Normal - JPEG: 1193 x 800 pix - 330k] [HiRes - JPEG: 5000 x 3354 pix - 10.0M] ESO PR Photo 07c/05 ESO PR Photo 07c/05 [Preview - JPEG: 537 x 400 pix - 31k] [Normal - JPEG: 1074 x 800 pix - 555k] [HiRes - JPEG: 3000 x 2235 pix - 6.0M] ESO PR Photo 07d/05 ESO PR Photo 07d/05 [Preview - JPEG: 400 x 550 pix - 60k] [Normal - JPEG: 800 x 1099 pix - 946k] [HiRes - JPEG: 2414 x 3316 pix - 11.0M] Captions: ESO PR Photo 07b/05 shows VLTI Auxiliary Telescopes 1 and 2 (AT1 and AT2) in the early evening light, with the spherical domes opened and ready for observations. In ESO PR Photo 07c/05, the same scene is repeated later in the evening, with three of the large telescope enclosures in the background. This photo and ESO PR Photo 07c/05 which is a time-exposure with AT1 and AT2 under the beautiful night sky with the southern Milky Way band were obtained by ESO staff member Frédéric Gomté. However, most of the time the large telescopes are used for other research purposes. They are therefore only available for interferometric observations during a limited number of nights every year. Thus, in order to exploit the VLTI each night and to achieve the full potential of this unique setup, some other (smaller), dedicated telescopes were included into the overall VLT concept. These telescopes, known as the VLTI Auxiliary Telescopes (ATs), are mounted on tracks and can be placed at precisely defined "parking" observing positions on the observatory platform. From these positions, their light beams are fed into the same common focal point via a complex system of reflecting mirrors mounted in an underground system of tunnels. The Auxiliary Telescopes are real technological jewels. They are placed in ultra-compact enclosures, complete with all necessary electronics, an air conditioning system and cooling liquid for thermal control, compressed air for enclosure seals, a hydraulic plant for opening the dome shells, etc. Each AT is also fitted with a transporter that lifts the telescope and relocates it from one station to another. It moves around with its own housing on the top of Paranal, almost like a snail. Moreover, these moving ultra-high precision telescopes, each weighing 33 tonnes, fulfill very stringent mechanical stability requirements: "The telescopes are unique in the world", says Bertrand Koehler, the VLTI AT Project Manager. "After being relocated to a new position, the telescope is repositioned to a precision better than one tenth of a millimetre - that is, the size of a human hair! The image of the star is stabilized to better than thirty milli-arcsec - this is how we would see an object of the same size as one of the VLT enclosures on the Moon. Finally, the path followed by the light inside the telescope after bouncing on ten mirrors is stable to better than a few nanometres, which is the size of about one hundred atoms." A World Premiere ESO PR Photo 07e/05 ESO PR Photo 07e/05 "First Fringes" with two ATs [Preview - JPEG: 400 x 559 pix - 61k] [Normal - JPEG: 800 x 1134 pix - 357k] Caption: ESO PR Photo 07e/05 The "First Fringes" obtained with the first two VLTI Auxiliary Telescopes, as seen on the computer screen during the observation. The fringe pattern arises when the light beams from the two 1.8-m telescopes are brought together inside the VINCI instrument. The pattern itself contains information about the angular extension of the observed object, here the 6th-magnitude star HD62082. The fringes are acquired by moving a mirror back and forth around the position of equal path length for the two telescopes. One such scan can be seen in the third row window. This pattern results from the raw interferometric signals (the last two rows) after calibration and filtering using the photometric signals (the 4th and 5th row). The first two rows show the spectrum of the fringe pattern signal. More details about the interpretation of this pattern is given in Appendix A of PR 06/01. The possibility to move the ATs around and thus to perform observations with a large number of different telescope configurations ensures a great degree of flexibility, unique for an optical interferometric installation of this size and crucial for its exceptional performance. The ATs may be placed at 30 different positions and thus be combined in a very large number of ways. If the 8.2-m VLT Unit Telescopes are also taken into account, no less than 254 independent pairings of two telescopes ("baselines"), different in length and/or orientation, are available. Moreover, while the largest possible distance between two 8.2-m telescopes (ANTU and YEPUN) is about 130 metres, the maximal distance between two ATs may reach 200 metres. As the achievable image sharpness increases with telescope separation, interferometric observations with the ATs positioned at the extreme positions will therefore yield sharper images than is possible by combining light from the large telescopes alone. All of this will enable the VLTI to obtain exceedingly detailed (sharp) and very complete images of celestial objects - ultimately with a resolution that corresponds to detecting an astronaut on the Moon. Auxiliary Telescope no. 1 (AT1) was installed on the observatory's platform in January 2004. Now, one year later, the second of the four to be delivered, has been integrated into the VLTI. The installation period lasted two months and ended around midnight during the night of February 2-3, 2005. With extensive experience from the installation of AT1, the team of engineers and astronomers were able to combine the light from the two Auxiliary Telescopes in a very short time. In fact, following the necessary preparations, it took them only five minutes to adjust this extremely complex optical system and successfully capture the "First Fringes" with the VINCI test instrument! The star which was observed is named HD62082 and is just at the limit of what can be observed with the unaided eye (its visual magnitude is 6.2). The fringes were as clear as ever, and the VLTI control system kept them stable for more than one hour. Four nights later this exercise was repeated successfully with the mid-infrared science instrument MIDI. Fringes on the star Alphard (Alpha Hydrae) were acquired on February 7 at 4:05 local time. For Roberto Gilmozzi, Director of ESO's La Silla Paranal Observatory, "this is a very important new milestone. The introduction of the Auxiliary Telescopes in the development of the VLT Interferometer will bring interferometry out of the specialist experiment and into the domain of common user instrumentation for every astronomer in Europe. Without doubt, it will enormously increase the potentiality of the VLTI." With two more telescopes to be delivered within a year to the Paranal Observatory, ESO cements its position as world-leader in ground-based optical astronomy, providing Europe's scientists with the tools they need to stay at the forefront in this exciting science. The VLT Interferometer will, for example, allow astronomers to study details on the surface of stars or to probe proto-planetary discs and other objects for which ultra-high precision imaging is required. It is premature to speculate on what the Very Large Telescope Interferometer will soon discover, but it is easy to imagine that there may be quite some surprises in store for all of us.
An Analysis of microRNA Expression in the Myelodysplastic Syndromes Using Hematopoietic Stem Cells
2015-10-01
AWARD NUMBER: W81XWH-13-1-0082 TITLE: An Analysis of microRNA Expression in the Myelodysplastic Syndromes Using Hematopoietic Stem Cells ...syndromes (MDS) to identify microRNAs (miRNAs) dysregulated in MDS hematopoietic stem cells (MDS HSCs) as compared with normal HSCs. MiRNAs differentially...the age-related predisposition for the development of MDS. 15. SUBJECT TERMS MicroRNAs, the myelodysplastic syndromes, hematopoietic stem cells
An Analysis of MicroRNA Expression in the Myelodysplastic Syndromes Using Hematopoietic Stem Cells
2015-10-01
AWARD NUMBER: W81XWH-13-1-0082 TITLE: An Analysis of microRNA Expression in the Myelodysplastic Syndromes Using Hematopoietic Stem Cells ...syndromes (MDS) to identify microRNAs (miRNAs) dysregulated in MDS hematopoietic stem cells (MDS HSCs) as compared with normal HSCs. MiRNAs differentially...the age-related predisposition for the development of MDS. 15. SUBJECT TERMS MicroRNAs, the myelodysplastic syndromes, hematopoietic stem cells
Nonlinear dynamic phase contrast microscopy for microfluidic and microbiological applications
NASA Astrophysics Data System (ADS)
Denz, C.; Holtmann, F.; Woerdemann, M.; Oevermann, M.
2008-08-01
In live sciences, the observation and analysis of moving living cells, molecular motors or motion of micro- and nano-objects is a current field of research. At the same time, microfluidic innovations are needed for biological and medical applications on a micro- and nano-scale. Conventional microscopy techniques are reaching considerable limits with respect to these issues. A promising approach for this challenge is nonlinear dynamic phase contrast microscopy. It is an alternative full field approach that allows to detect motion as well as phase changes of living unstained micro-objects in real-time, thereby being marker free, without contact and non destructive, i.e. fully biocompatible. The generality of this system allows it to be combined with several other microscope techniques such as conventional bright field or fluorescence microscopy. In this article we will present the dynamic phase contrast technique and its applications in analysis of micro organismic dynamics, micro flow velocimetry and micro-mixing analysis.
NASA Astrophysics Data System (ADS)
Shulga, A. V.; Kozyrev, E. S.; Kovalchuk, A. N.; Chernozub, V. M.; Sibiryakova, E. S.; Bochkarev, A. B.; Lopachenko, V. V.; Ryhalsky, V. V.
2010-05-01
Modern tasks for orbit control of the Earth artificial satellites and objects approaching the Earth define high requirements to ground-based telescopes, which have to be equipped with fast objectives, CCD cameras with a chip size not less than two inches. The CCD camera has to work in different modes. The telescopes must be fully robotized, and have a control system with remote operation and alert mode. In cooperation between RI NAO and NSFCTC, the upgrade of the AZT-8 classical telescope, belonging to NSFCTC, was made. Two telescopes of original design, namely the Fast Robotic Telescope (FRT) and the Mobile Telescope (MobiTel) were made in RI NAO. The telescopes are equipped with absolute angle encoders, CCD cameras with Kodak KAF-09000 chips, GPS time service, robotic drives and an automatic control system. The telescope features, such as a telescope name, f-number, chip name and operating modes, pixel numbers, field of view, pixel sizes, pixel scale, limiting magnitude, the standard deviation are given in the following list: 1) AZT-8(NSFCTC), 0.7/2.8 m, FLI PL09000 stare, 3056x3056, 45x45', 12x12 μm, 0.9"/pix, 20m, 0.05"/0.15"; 2) FRT (NAO), 0.3/1.5 m, Alta U9000stare and drift-scan, 3056x3056, 1°24'x1°24', 12x12 μm, 1.6"/pix, 18m, 0.15"/0.40"; 3) MobiTel-0.5(NAO), 0.5/3.0 m, Alta U9000stare and drift-scan,3056x3056, 42x42, 12x12μm, 0.8"/pix, 19m,0.0"05"/0".15"; 4) MobiTel-0.3(NAO), 0.3/0.75 m, Alta U9000 stare and drift-scan, 3056x3056, 2°48x2°48', 12x12 μm, 3.2"/pix, 18 m, 0.20"/0.45". The telescopes are actively used for control of the near-Earth space as well as for the solution of problems connected with thepotentially hazardous asteroids and comets approaching the Earth. Combination of classical and original methods of observations allows us to carry out virtually any observing programme. Considering objects at geostationary orbits and at highly elliptical orbits, we are able to carry out the following types of observations: massive-survey, boundary-search, high accuracy-single object. To solve the problems connected with the potentially hazardous asteroids and comets approaching the Earth, we are able to observe faint objects located in the asteroid belt as well as objects approaching the Earth at the distance less than 0.1 a.u. and with elongation angle up to 130°.
Reconfigurable and responsive droplet-based compound micro-lenses.
Nagelberg, Sara; Zarzar, Lauren D; Nicolas, Natalie; Subramanian, Kaushikaram; Kalow, Julia A; Sresht, Vishnu; Blankschtein, Daniel; Barbastathis, George; Kreysing, Moritz; Swager, Timothy M; Kolle, Mathias
2017-03-07
Micro-scale optical components play a crucial role in imaging and display technology, biosensing, beam shaping, optical switching, wavefront-analysis, and device miniaturization. Herein, we demonstrate liquid compound micro-lenses with dynamically tunable focal lengths. We employ bi-phase emulsion droplets fabricated from immiscible hydrocarbon and fluorocarbon liquids to form responsive micro-lenses that can be reconfigured to focus or scatter light, form real or virtual images, and display variable focal lengths. Experimental demonstrations of dynamic refractive control are complemented by theoretical analysis and wave-optical modelling. Additionally, we provide evidence of the micro-lenses' functionality for two potential applications-integral micro-scale imaging devices and light field display technology-thereby demonstrating both the fundamental characteristics and the promising opportunities for fluid-based dynamic refractive micro-scale compound lenses.
Reconfigurable and responsive droplet-based compound micro-lenses
Nagelberg, Sara; Zarzar, Lauren D.; Nicolas, Natalie; Subramanian, Kaushikaram; Kalow, Julia A.; Sresht, Vishnu; Blankschtein, Daniel; Barbastathis, George; Kreysing, Moritz; Swager, Timothy M.; Kolle, Mathias
2017-01-01
Micro-scale optical components play a crucial role in imaging and display technology, biosensing, beam shaping, optical switching, wavefront-analysis, and device miniaturization. Herein, we demonstrate liquid compound micro-lenses with dynamically tunable focal lengths. We employ bi-phase emulsion droplets fabricated from immiscible hydrocarbon and fluorocarbon liquids to form responsive micro-lenses that can be reconfigured to focus or scatter light, form real or virtual images, and display variable focal lengths. Experimental demonstrations of dynamic refractive control are complemented by theoretical analysis and wave-optical modelling. Additionally, we provide evidence of the micro-lenses' functionality for two potential applications—integral micro-scale imaging devices and light field display technology—thereby demonstrating both the fundamental characteristics and the promising opportunities for fluid-based dynamic refractive micro-scale compound lenses. PMID:28266505
Local x-ray structure analysis of optically manipulated biological micro-objects
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cojoc, Dan; Ferrari, Enrico; Santucci, Silvia C.
2010-12-13
X-ray diffraction using micro- and nanofocused beams is well suited for nanostructure analysis at different sites of a biological micro-object. To conduct in vitro studies without mechanical contact, we developed object manipulation by optical tweezers in a microfluidic cell. Here we report x-ray microdiffraction analysis of a micro-object optically trapped in three dimensions. We revealed the nanostructure of a single starch granule at different points and investigated local radiation damage induced by repeated x-ray exposures at the same position, demonstrating high stability and full control of the granule orientation by multiple optical traps.
Kobayashi, Masaaki; Nagasaki, Hideki; Garcia, Virginie; Just, Daniel; Bres, Cécile; Mauxion, Jean-Philippe; Le Paslier, Marie-Christine; Brunel, Dominique; Suda, Kunihiro; Minakuchi, Yohei; Toyoda, Atsushi; Fujiyama, Asao; Toyoshima, Hiromi; Suzuki, Takayuki; Igarashi, Kaori; Rothan, Christophe; Kaminuma, Eli; Nakamura, Yasukazu; Yano, Kentaro; Aoki, Koh
2014-02-01
Tomato (Solanum lycopersicum) is regarded as a model plant of the Solanaceae family. The genome sequencing of the tomato cultivar 'Heinz 1706' was recently completed. To accelerate the progress of tomato genomics studies, systematic bioresources, such as mutagenized lines and full-length cDNA libraries, have been established for the cultivar 'Micro-Tom'. However, these resources cannot be utilized to their full potential without the completion of the genome sequencing of 'Micro-Tom'. We undertook the genome sequencing of 'Micro-Tom' and here report the identification of single nucleotide polymorphisms (SNPs) and insertion/deletions (indels) between 'Micro-Tom' and 'Heinz 1706'. The analysis demonstrated the presence of 1.23 million SNPs and 0.19 million indels between the two cultivars. The density of SNPs and indels was high in chromosomes 2, 5 and 11, but was low in chromosomes 6, 8 and 10. Three known mutations of 'Micro-Tom' were localized on chromosomal regions where the density of SNPs and indels was low, which was consistent with the fact that these mutations were relatively new and introgressed into 'Micro-Tom' during the breeding of this cultivar. We also report SNP analysis for two 'Micro-Tom' varieties that have been maintained independently in Japan and France, both of which have served as standard lines for 'Micro-Tom' mutant collections. Approximately 28,000 SNPs were identified between these two 'Micro-Tom' lines. These results provide high-resolution DNA polymorphic information on 'Micro-Tom' and represent a valuable contribution to the 'Micro-Tom'-based genomics resources.
DIANA-microT web server v5.0: service integration into miRNA functional analysis workflows.
Paraskevopoulou, Maria D; Georgakilas, Georgios; Kostoulas, Nikos; Vlachos, Ioannis S; Vergoulis, Thanasis; Reczko, Martin; Filippidis, Christos; Dalamagas, Theodore; Hatzigeorgiou, A G
2013-07-01
MicroRNAs (miRNAs) are small endogenous RNA molecules that regulate gene expression through mRNA degradation and/or translation repression, affecting many biological processes. DIANA-microT web server (http://www.microrna.gr/webServer) is dedicated to miRNA target prediction/functional analysis, and it is being widely used from the scientific community, since its initial launch in 2009. DIANA-microT v5.0, the new version of the microT server, has been significantly enhanced with an improved target prediction algorithm, DIANA-microT-CDS. It has been updated to incorporate miRBase version 18 and Ensembl version 69. The in silico-predicted miRNA-gene interactions in Homo sapiens, Mus musculus, Drosophila melanogaster and Caenorhabditis elegans exceed 11 million in total. The web server was completely redesigned, to host a series of sophisticated workflows, which can be used directly from the on-line web interface, enabling users without the necessary bioinformatics infrastructure to perform advanced multi-step functional miRNA analyses. For instance, one available pipeline performs miRNA target prediction using different thresholds and meta-analysis statistics, followed by pathway enrichment analysis. DIANA-microT web server v5.0 also supports a complete integration with the Taverna Workflow Management System (WMS), using the in-house developed DIANA-Taverna Plug-in. This plug-in provides ready-to-use modules for miRNA target prediction and functional analysis, which can be used to form advanced high-throughput analysis pipelines.
DIANA-microT web server v5.0: service integration into miRNA functional analysis workflows
Paraskevopoulou, Maria D.; Georgakilas, Georgios; Kostoulas, Nikos; Vlachos, Ioannis S.; Vergoulis, Thanasis; Reczko, Martin; Filippidis, Christos; Dalamagas, Theodore; Hatzigeorgiou, A.G.
2013-01-01
MicroRNAs (miRNAs) are small endogenous RNA molecules that regulate gene expression through mRNA degradation and/or translation repression, affecting many biological processes. DIANA-microT web server (http://www.microrna.gr/webServer) is dedicated to miRNA target prediction/functional analysis, and it is being widely used from the scientific community, since its initial launch in 2009. DIANA-microT v5.0, the new version of the microT server, has been significantly enhanced with an improved target prediction algorithm, DIANA-microT-CDS. It has been updated to incorporate miRBase version 18 and Ensembl version 69. The in silico-predicted miRNA–gene interactions in Homo sapiens, Mus musculus, Drosophila melanogaster and Caenorhabditis elegans exceed 11 million in total. The web server was completely redesigned, to host a series of sophisticated workflows, which can be used directly from the on-line web interface, enabling users without the necessary bioinformatics infrastructure to perform advanced multi-step functional miRNA analyses. For instance, one available pipeline performs miRNA target prediction using different thresholds and meta-analysis statistics, followed by pathway enrichment analysis. DIANA-microT web server v5.0 also supports a complete integration with the Taverna Workflow Management System (WMS), using the in-house developed DIANA-Taverna Plug-in. This plug-in provides ready-to-use modules for miRNA target prediction and functional analysis, which can be used to form advanced high-throughput analysis pipelines. PMID:23680784
Aguirre-Gamboa, Raul; Trevino, Victor
2014-06-01
MicroRNAs (miRNAs) play a key role in post-transcriptional regulation of mRNA levels. Their function in cancer has been studied by high-throughput methods generating valuable sources of public information. Thus, miRNA signatures predicting cancer clinical outcomes are emerging. An important step to propose miRNA-based biomarkers before clinical validation is their evaluation in independent cohorts. Although it can be carried out using public data, such task is time-consuming and requires a specialized analysis. Therefore, to aid and simplify the evaluation of prognostic miRNA signatures in cancer, we developed SurvMicro, a free and easy-to-use web tool that assesses miRNA signatures from publicly available miRNA profiles using multivariate survival analysis. SurvMicro is composed of a wide and updated database of >40 cohorts in different tissues and a web tool where survival analysis can be done in minutes. We presented evaluations to portray the straightforward functionality of SurvMicro in liver and lung cancer. To our knowledge, SurvMicro is the only bioinformatic tool that aids the evaluation of multivariate prognostic miRNA signatures in cancer. SurvMicro and its tutorial are freely available at http://bioinformatica.mty.itesm.mx/SurvMicro. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
ERIC Educational Resources Information Center
Brown, Joan Marie
1996-01-01
Describes a multimedia math activity for sixth-grade students who have access to a computer lab. Students work in groups and interview an adult who uses math in his or her job. Then, they write an explanatory narrative describing how that adult uses math. Finally, they create a KidPix video slideshow with voice overlays to share with the class.…
Rieger, R; Auregan, J C; Hoc, T
2018-03-01
The objective of the present study is to assess the mechanical behavior of trabecular bone based on microCT imaging and micro-finite-element analysis. In this way two methods are detailed: (i) direct determination of macroscopic elastic property of trabecular bone; (ii) inverse approach to assess mechanical properties of trabecular bone tissue. Thirty-five females and seven males (forty-two subjects) mean aged (±SD) 80±11.7 years from hospitals of Assistance publique-Hôpitaux de Paris (AP-HP) diagnosed with osteoporosis following a femoral neck fracture due to a fall from standing were included in this study. Fractured heads were collected during hip replacement surgery. Standardized bone cores were removed from the femoral head's equator by a trephine in a water bath. MicroCT images acquisition and analysis were performed with CTan ® software and bone volume fraction was then determined. Micro-finite-element simulations were per-formed using Abaqus 6.9-2 ® software in order to determine the macroscopic mechanical behaviour of the trabecular bone. After microCT acquisition, a longitudinal compression test was performed and the experimental macroscopic Young's Modulus was extracted. An inverse approach based on the whole trabecular bone's mechanical response and micro-finite-element analysis was performed to determine microscopic mechanical properties of trabecular bone. In the present study, elasticity of the tissue was shown to be similar to that of healthy tissue but with a lower yield stress. Classical histomorphometric analysis form microCT imaging associated with an inverse micro-finite-element method allowed to assess microscopic mechanical trabecular bone parameters. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Svarcová, Silvie; Kocí, Eva; Bezdicka, Petr; Hradil, David; Hradilová, Janka
2010-09-01
The uniqueness and limited amounts of forensic samples and samples from objects of cultural heritage together with the complexity of their composition requires the application of a wide range of micro-analytical methods, which are non-destructive to the samples, because these must be preserved for potential late revision. Laboratory powder X-ray micro-diffraction (micro-XRD) is a very effective non-destructive technique for direct phase analysis of samples smaller than 1 mm containing crystal constituents. It compliments optical and electron microscopy with elemental micro-analysis, especially in cases of complicated mixtures containing phases with similar chemical composition. However, modification of X-ray diffraction to the micro-scale together with its application for very heterogeneous real samples leads to deviations from the standard procedure. Knowledge of both the limits and the phenomena which can arise during the analysis is crucial for the meaningful and proper application of the method. We evaluated basic limits of micro-XRD equipped with a mono-capillary with an exit diameter of 0.1 mm, for example the size of irradiated area, appropriate grain size, and detection limits allowing identification of given phases. We tested the reliability and accuracy of quantitative phase analysis based on micro-XRD data in comparison with conventional XRD (reflection and transmission), carrying out experiments with two-phase model mixtures simulating historic colour layers. Furthermore, we demonstrate the wide use of micro-XRD for investigation of various types of micro-samples (contact traces, powder traps, colour layers) and we show how to enhance data quality by proper choice of experiment geometry and conditions.
Lin, Yuxin; Chen, Feifei; Shen, Li; Tang, Xiaoyu; Du, Cui; Sun, Zhandong; Ding, Huijie; Chen, Jiajia; Shen, Bairong
2018-05-21
Prostate cancer (PCa) is a fatal malignant tumor among males in the world and the metastasis is a leading cause for PCa death. Biomarkers are therefore urgently needed to detect PCa metastatic signature at the early time. MicroRNAs are small non-coding RNAs with the potential to be biomarkers for disease prediction. In addition, computer-aided biomarker discovery is now becoming an attractive paradigm for precision diagnosis and prognosis of complex diseases. In this study, we identified key microRNAs as biomarkers for predicting PCa metastasis based on network vulnerability analysis. We first extracted microRNAs and mRNAs that were differentially expressed between primary PCa and metastatic PCa (MPCa) samples. Then we constructed the MPCa-specific microRNA-mRNA network and screened microRNA biomarkers by a novel bioinformatics model. The model emphasized the characterization of systems stability changes and the network vulnerability with three measurements, i.e. the structurally single-line regulation, the functional importance of microRNA targets and the percentage of transcription factor genes in microRNA unique targets. With this model, we identified five microRNAs as putative biomarkers for PCa metastasis. Among them, miR-101-3p and miR-145-5p have been previously reported as biomarkers for PCa metastasis and the remaining three, i.e. miR-204-5p, miR-198 and miR-152, were screened as novel biomarkers for PCa metastasis. The results were further confirmed by the assessment of their predictive power and biological function analysis. Five microRNAs were identified as candidate biomarkers for predicting PCa metastasis based on our network vulnerability analysis model. The prediction performance, literature exploration and functional enrichment analysis convinced our findings. This novel bioinformatics model could be applied to biomarker discovery for other complex diseases.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Salcedo, D.; Laskin, Alexander; Shutthanandan, V.
The feasibility of using an online thermal-desorption electron-ionization high-resolution aerosol mass spectrometer (AMS) for the detection of particulate trace elements was investigated analyzing data from Mexico City obtained during the MILAGRO 2006 field campaign, where relatively high concentrations of trace elements have been reported. This potential application is of interest due to the real-time data provided by the AMS, its high sensitivity and time resolution, and the widespread availability and use of this instrument. High resolution mass spectral analysis, isotopic ratios, and ratios of different ions containing the same elements are used to constrain the chemical identity of the measuredmore » ions. The detection of Cu, Zn, As, Se, Sn, and Sb is reported. There was no convincing evidence for the detection of other trace elements commonly reported in PM. The elements detected tend to be those with lower melting and boiling points, as expected given the use of a vaporizer at 600oC in this instrument. Operation of the AMS vaporizer at higher temperatures is likely to improve trace element detection. The detection limit is estimated at approximately 0.3 ng m-3 for 5-min of data averaging. Concentration time series obtained from the AMS data were compared to concentration records determined from offline analysis of particle samples from the same times and locations by ICP (PM2.5) and PIXE (PM1.1 and PM0.3). The degree of correlation and agreement between the three instruments (AMS, ICP, and PIXE) varied depending on the element. The AMS shows promise for real-time detection of some trace elements, although additional work including laboratory calibrations with different chemical forms of these elements are needed to further develop this technique and to understand the differences with the ambient data from the other techniques. The trace elements peaked in the morning as expected for primary sources, and the many detected plumes suggest the presence of multiple point sources, probably industrial, in Mexico City which are variable in time and space, in agreement with previous studies.« less
Comparative analysis of aerosols elemental distribution in some Romanian regions
NASA Astrophysics Data System (ADS)
Amemiya, Susumu; Masuda, Toshio; Popa-Simil, Liviu; Mateescu, Liviu
1996-04-01
The study's main aim is obtaining aerosols particulate elemental distribution and mapping it for some Romanian regions, in order to obtain preliminary information regarding the concentrations of aerosol particles and networking strategy versus local conditions. For this we used the mobile sampling strategy, but taking care on all local specific conditions and weather. In the summer of 1993, in July we took about 8 samples on a rather large territory of SE Romania which were analysed and mapped. The regions which showed an interesting behaviour or doubts such as Bucharest and Dobrogea were zoomed in near the same period of 1994, for comparing the new details with the global aspect previously obtained. An attempt was made to infer the minimum necessary number of stations in a future monitoring network. A mobile sampler was used, having tow polycarbonate filter posts of 8 and 0.4 μm. PIXE elemental analysis was performed on a 2.5 MV Van de Graaff accelerator, by using a proton beam. More than 15 elements were measured. Suggestive 2D and 3D representations were drawn, as well as histogram charts for the concentrations' distribution in the specific regions at the specified times. In spite of the poor samples from the qualitative point of view the experiment surprised us by the good coincidence (good agreement) with realities in terrain known by other means long time ago, and highlighted the power of PIXE methods in terms of money and time. Conclusions over the link between industry, traffic, vegetation, wether, surface waters, soil composition, power plant exhaust and so on, on the one hand, and surface concentration distribution, on the other, were drawn. But the method's weak points were also highlighted; these are weather dependencies (especially air masses movement and precipitation), local relief, microclimate and vegetation, and of course localisation of the sampling point versus the pollution sources and their regime. The paper contains a synthesis of the whole of the maps and graphs we made, intended in its turn to demonstrate the necessity of a national integrated network for monitoring aerosols.
Alanazi, Ibrahim O; Ebrahimie, Esmaeil
2016-07-01
Novel computational systems biology tools such as common targets analysis, common regulators analysis, pathway discovery, and transcriptomic-based hotspot discovery provide new opportunities in understanding of apoptosis molecular mechanisms. In this study, after measuring the global contribution of microRNAs in the course of apoptosis by Affymetrix platform, systems biology tools were utilized to obtain a comprehensive view on the role of microRNAs in apoptosis process. Network analysis and pathway discovery highlighted the crosstalk between transcription factors and microRNAs in apoptosis. Within the transcription factors, PRDM1 showed the highest upregulation during the course of apoptosis, with more than 9-fold expression increase compared to non-apoptotic condition. Within the microRNAs, MIR1208 showed the highest expression in non-apoptotic condition and downregulated by more than 6 fold during apoptosis. Common regulators algorithm showed that TNF receptor is the key upstream regulator with a high number of regulatory interactions with the differentially expressed microRNAs. BCL2 and AKT1 were the key downstream targets of differentially expressed microRNAs. Enrichment analysis of the genomic locations of differentially expressed microRNAs led us to the discovery of chromosome bands which were highly enriched (p < 0.01) with the apoptosis-related microRNAs, such as 13q31.3, 19p13.13, and Xq27.3 This study opens a new avenue in understanding regulatory mechanisms and downstream functions in the course of apoptosis as well as distinguishing genomic-enriched hotspots for apoptosis process.
Monitoring Ion Track Formation Using In Situ RBS/c, ToF-ERDA, and HR-PIXE.
Karlušić, Marko; Fazinić, Stjepko; Siketić, Zdravko; Tadić, Tonči; Cosic, Donny Domagoj; Božičević-Mihalić, Iva; Zamboni, Ivana; Jakšić, Milko; Schleberger, Marika
2017-09-06
The aim of this work is to investigate the feasibility of ion beam analysis techniques for monitoring swift heavy ion track formation. First, the use of the in situ Rutherford backscattering spectrometry in channeling mode to observe damage build-up in quartz SiO₂ after MeV heavy ion irradiation is demonstrated. Second, new results of the in situ grazing incidence time-of-flight elastic recoil detection analysis used for monitoring the surface elemental composition during ion tracks formation in various materials are presented. Ion tracks were found on SrTiO₃, quartz SiO₂, a-SiO₂, and muscovite mica surfaces by atomic force microscopy, but in contrast to our previous studies on GaN and TiO₂, surface stoichiometry remained unchanged. Third, the usability of high resolution particle induced X-ray spectroscopy for observation of electronic dynamics during early stages of ion track formation is shown.
Monitoring Ion Track Formation Using In Situ RBS/c, ToF-ERDA, and HR-PIXE
Karlušić, Marko; Fazinić, Stjepko; Siketić, Zdravko; Tadić, Tonči; Cosic, Donny Domagoj; Božičević-Mihalić, Iva; Zamboni, Ivana; Jakšić, Milko; Schleberger, Marika
2017-01-01
The aim of this work is to investigate the feasibility of ion beam analysis techniques for monitoring swift heavy ion track formation. First, the use of the in situ Rutherford backscattering spectrometry in channeling mode to observe damage build-up in quartz SiO2 after MeV heavy ion irradiation is demonstrated. Second, new results of the in situ grazing incidence time-of-flight elastic recoil detection analysis used for monitoring the surface elemental composition during ion tracks formation in various materials are presented. Ion tracks were found on SrTiO3, quartz SiO2, a-SiO2, and muscovite mica surfaces by atomic force microscopy, but in contrast to our previous studies on GaN and TiO2, surface stoichiometry remained unchanged. Third, the usability of high resolution particle induced X-ray spectroscopy for observation of electronic dynamics during early stages of ion track formation is shown. PMID:28878186
NASA Astrophysics Data System (ADS)
Limić, Nedzad; Valković, Vladivoj
1996-04-01
Pollution of coastal seas with toxic substances can be efficiently detected by examining toxic materials in sediment samples. These samples contain information on the overall pollution from surrounding sources such as yacht anchorages, nearby industries, sewage systems, etc. In an efficient analysis of pollution one must determine the contribution from each individual source. In this work it is demonstrated that a modelling method can be utilized for solving this latter problem. The modelling method is based on a unique interpretation of concentrations in sediments from all sampling stations. The proposed method is a synthesis consisting of the utilization of PIXE as an efficient method of pollution concentration determination and the code ANCOPOL (N. Limic and R. Benis, The computer code ANCOPOL, SimTel/msdos/geology, 1994 [1]) for the calculation of contributions from the main polluters. The efficiency and limits of the proposed method are demonstrated by discussing trace element concentrations in sediments of Punat Bay on the island of Krk in Croatia.
Application of Nexus copy number software for CNV detection and analysis.
Darvishi, Katayoon
2010-04-01
Among human structural genomic variation, copy number variants (CNVs) are the most frequently known component, comprised of gains/losses of DNA segments that are generally 1 kb in length or longer. Array-based comparative genomic hybridization (aCGH) has emerged as a powerful tool for detecting genomic copy number variants (CNVs). With the rapid increase in the density of array technology and with the adaptation of new high-throughput technology, a reliable and computationally scalable method for accurate mapping of recurring DNA copy number aberrations has become a main focus in research. Here we introduce Nexus Copy Number software, a platform-independent tool, to analyze the output files of all types of commercial and custom-made comparative genomic hybridization (CGH) and single-nucleotide polymorphism (SNP) arrays, such as those manufactured by Affymetrix, Agilent Technologies, Illumina, and Roche NimbleGen. It also supports data generated by various array image-analysis software tools such as GenePix, ImaGene, and BlueFuse. (c) 2010 by John Wiley & Sons, Inc.
Nuclear physics for materials technology
NASA Astrophysics Data System (ADS)
Conlon, T. W.
1987-04-01
Although particle accelerators have traditionally been used to further our knowledge of nuclear physics, the last decade or so has seen a rapid growth of their involvement in materials technology — both to modify materials and to provide analytical information at the atomic level that cannot be obtained in other ways. The deployment of ion beams in these areas has occurred in three phases: first the exploitation of keV ion beams (in ion implantation and SIMS) then MeV light ion beams (using RBS, NRA, PIXE analysis and TLA) and currently MeV heavy ion beams, together with the associated fast recoil atoms and nuclei that they produce in interactions with materials. This trend has been accompanied by the gradual assimilation of methods such as energy analysis, microbeam focussing, particle identification, time of flight and coincidence techniques, etc., which were first developed for experimental nuclear physics use. Current examples of developments in the MeV range relevant to phases 2 and 3 are given.
Method and apparatus for actively controlling a micro-scale flexural plate wave device
Dohner, Jeffrey L.
2001-01-01
An actively controlled flexural plate wave device provides a micro-scale pump. A method of actively controlling a flexural plate wave device produces traveling waves in the device by coordinating the interaction of a magnetic field with actively controlled currents. An actively-controlled flexural plate wave device can be placed in a fluid channel and adapted for use as a micro-scale fluid pump to cool or drive micro-scale systems, for example, micro-chips, micro-electrical-mechanical devices, micro-fluid circuits, or micro-scale chemical analysis devices.
Tapocik, Jenica D.; Solomon, Matthew; Flanigan, Meghan; Meinhardt, Marcus; Barbier, Estelle; Schank, Jesse; Schwandt, Melanie; Sommer, Wolfgang H.; Heilig, Markus
2012-01-01
Long-term changes in brain gene expression have been identified in alcohol dependence, but underlying mechanisms remain unknown. Here, we examined the potential role of microRNAs for persistent gene expression changes in the rat medial prefrontal cortex after a history of alcohol dependence. Two-bottle free-choice alcohol consumption increased following 7-week exposure to intermittent alcohol intoxication. A bioinformatic approach using microarray analysis, qPCR, bioinformatic analysis, and microRNA-mRNA integrative analysis identified expression patterns indicative of a disruption in synaptic processes and neuroplasticity. 41 rat-microRNAs and 165 mRNAs in the medial prefrontal cortex were significantly altered after chronic alcohol exposure. A subset of the microRNAs and mRNAs was confirmed by qPCR. Gene ontology categories of differential expression pointed to functional processes commonly associated with neurotransmission, neuroadaptation, and synaptic plasticity. microRNA-mRNA expression pairing identified 33 microRNAs putatively targeting 89 mRNAs suggesting transcriptional networks involved in axonal guidance and neurotransmitter signaling. Our results demonstrate a significant shift in microRNA expression patterns in the medial prefrontal cortex following a history of dependence. Due to their global regulation of multiple downstream target transcripts, microRNAs may play a pivotal role in the reorganization of synaptic connections and long term neuroadaptations in alcohol dependence. microRNA-mediated alterations of transcriptional networks may be involved in disrupted prefrontal control over alcohol-drinking observed in alcoholic patients. PMID:22614244
First-Ever Census of Variable Mira-Type Stars in Galaxy Outside the Local Group
NASA Astrophysics Data System (ADS)
2003-05-01
First-Ever Census of Variable Mira-Type Stars in Galaxy Outsidethe Local Group Summary An international team led by ESO astronomer Marina Rejkuba [1] has discovered more than 1000 luminous red variable stars in the nearby elliptical galaxy Centaurus A (NGC 5128) . Brightness changes and periods of these stars were measured accurately and reveal that they are mostly cool long-period variable stars of the so-called "Mira-type" . The observed variability is caused by stellar pulsation. This is the first time a detailed census of variable stars has been accomplished for a galaxy outside the Local Group of Galaxies (of which the Milky Way galaxy in which we live is a member). It also opens an entirely new window towards the detailed study of stellar content and evolution of giant elliptical galaxies . These massive objects are presumed to play a major role in the gravitational assembly of galaxy clusters in the Universe (especially during the early phases). This unprecedented research project is based on near-infrared observations obtained over more than three years with the ISAAC multi-mode instrument at the 8.2-m VLT ANTU telescope at the ESO Paranal Observatory . PR Photo 14a/03 : Colour image of the peculiar galaxy Centaurus A . PR Photo 14b/03 : Location of the fields in Centaurus A, now studied. PR Photo 14c/03 : "Field 1" in Centaurus A (visual light; FORS1). PR Photo 14d/03 : "Field 2" in Centaurus A (visual light; FORS1). PR Photo 14e/03 : "Field 1" in Centaurus A (near-infrared; ISAAC). PR Photo 14f/03 : "Field 2" in Centaurus A (near-infrared; ISAAC). PR Photo 14g/03 : Light variation of six variable stars in Centaurus A PR Photo 14h/03 : Light variation of stars in Centaurus A (Animated GIF) PR Photo 14i/03 : Light curves of four variable stars in Centaurus A. Mira-type variable stars Among the stars that are visible in the sky to the unaided eye, roughly one out of three hundred (0.3%) displays brightness variations and is referred to by astronomers as a "variable star". The percentage is much higher among large, cool stars ("red giants") - in fact, almost all luminous stars of that type are variable. Such stars are known as Mira-variables ; the name comes from the most prominent member of this class, Omicron Ceti in the constellation Cetus (The Whale), also known as "Stella Mira" (The Wonderful Star). Its brightness changes with a period of 332 days and it is about 1500 times brighter at maximum (visible magnitude 2 and one of the fifty brightest stars in the sky) than at minimum (magnitude 10 and only visible in small telescopes) [2]. Stars like Omicron Ceti are nearing the end of their life. They are very large and have sizes from a few hundred to about a thousand times that of the Sun. The brightness variation is due to pulsations during which the star's temperature and size change dramatically. In the following evolutionary phase, Mira-variables will shed their outer layers into surrounding space and become visible as planetary nebulae with a hot and compact star (a "white dwarf") at the middle of a nebula of gas and dust (cf. the "Dumbbell Nebula" - ESO PR Photo 38a-b/98 ). Several thousand Mira-type stars are currently known in the Milky Way galaxy and a few hundred have been found in other nearby galaxies, including the Magellanic Clouds. The peculiar galaxy Centaurus A ESO PR Photo 14a/03 ESO PR Photo 14a/03 [Preview - JPEG: 400 x 451 pix - 53k [Normal - JPEG: 800 x 903 pix - 528k] [Hi-Res - JPEG: 3612 x 4075 pix - 8.4M] ESO PR Photo 14b/03 ESO PR Photo 14b/03 [Preview - JPEG: 570 x 400 pix - 52k [Normal - JPEG: 1140 x 800 pix - 392k] ESO PR Photo 14c/03 ESO PR Photo 14c/03 [Preview - JPEG: 400 x 451 pix - 61k [Normal - JPEG: 800 x 903 pix - 768k] ESO PR Photo 14d/03 ESO PR Photo 14d/03 [Preview - JPEG: 400 x 451 pix - 56k [Normal - JPEG: 800 x 903 pix - 760k] Captions : PR Photo 14a/03 is a colour composite photo of the peculiar galaxy Centaurus A (NGC 5128) , obtained with the Wide-Field Imager (WFI) camera at the ESO/MPG 2.2-m telescope on La Silla. It is based on a total of nine 3-min exposures made on March 25, 1999, through different broad-band optical filters (B(lue) - total exposure time 9 min - central wavelength 456 nm - here rendered as blue; V(isual) - 540 nm - 9 min - green; I(nfrared) - 784 nm - 9 min - red); it was prepared from files in the ESO Science Data Archive by ESO-astronomer Benoît Vandame . The elliptical shape and the central dust band, the imprint of a galaxy collision, are well visible. PR Photo 14b/03 identifies the two regions of Centaurus A (the rectangles in the upper left and lower right inserts) in which a search for variable stars was made during the present research project: "Field 1" is located in an area north-east of the center in which many young stars are present. This is also the direction in which an outflow ("jet") is seen on deep optical and radio images. "Field 2" is positioned in the galaxy's halo, south of the centre. High-resolution, very deep colour photos of these two fields and their immediate surroundings are shown in PR Photos 14c-d/03 . They were produced by means of CCD-frames obtained in July 1999 through U- and V-band optical filters with the VLT FORS1 multi-mode instrument at the 8.2-m VLT ANTU telescope on Paranal. Note the great variety of object types and colours, including many background galaxies which are seen through these less dense regions of Centaurus A . The total exposure time was 30 min in each filter and the seeing was excellent, 0.5 arcsec. The original pixel size is 0.196 arcsec and the fields measure 6.7 x 6.7 arcmin 2 (2048 x 2048 pix 2 ). North is up and East is left on all photos. Centaurus A (NGC 5128) is the nearest giant galaxy, at a distance of about 13 million light-years. It is located outside the Local Group of Galaxies to which our own galaxy, the Milky Way, and its satellite galaxies, the Magellanic Clouds, belong. Centaurus A is seen in the direction of the southern constellation Centaurus. It is of elliptical shape and is currently merging with a companion galaxy, making it one of the most spectacular objects in the sky, cf. PR Photo 14a/03 . It possesses a very heavy black hole at its centre (see ESO PR 04/01 ) and is a source of strong radio and X-ray emission. During the present research programme, two regions in Centaurus A were searched for stars of variable brightness; they are located in the periphery of this peculiar galaxy, cf. PR Photos 14b-d/03 . An outer field ("Field 1") coincides with a stellar shell with many blue and luminous stars produced by the on-going galaxy merger; it lies at a distance of 57,000 light-years from the centre. The inner field ("Field 2") is more crowded and is situated at a projected distance of about 30,000 light-years from the centre.. Three years of VLT observations ESO PR Photo 14e/03 ESO PR Photo 14e/03 [Preview - JPEG: 400 x 447 pix - 120k [Normal - JPEG: 800 x 894 pix - 992k] ESO PR Photo 14f/03 ESO PR Photo 14f/03 [Preview - JPEG: 400 x 450 pix - 96k [Normal - JPEG: 800 x 899 pix - 912k] Caption : PR Photos 14e-f/03 are colour composites of two small fields ("Field 1" and "Field 2") in the peculiar galaxy Centaurus A (NGC 5128) , based on exposures through three near-infrared filters (the J-, H- and K-bands at wavelengths 1.2, 1.6 and 2.2 µm, respectively) with the ISAAC multi-mode instrument at the 8.2-m VLT ANTU telescope at the ESO Paranal observatory. The corresponding areas are outlined within the two inserts in PR Photo 14b/03 and may be compared with the visual images from FORS1 ( PR Photos 14c-d/03 ). These ISAAC photos are the deepest near-infrared images ever obtained in this galaxy and show thousands of its stars of different colours. In the present colour-coding, the redder an image, the cooler is the star. The original pixel size is 0.15 arcsec and both fields measure 2.5 x 2.5 arcmin 2. North is up and East is left. Under normal circumstances, any team of professional astronomers will have access to the largest telescopes in the world for only a very limited number of consecutive nights each year. However, extensive searches for variable stars like the present require repeated observations lasting minutes-to-hours over periods of months-to-years. It is thus not feasible to perform such observations in the classical way in which the astronomers travel to the telescope each time. Fortunately, the operational system of the VLT at the ESO Paranal Observatory (Chile) is also geared to encompass this kind of long-term programme. Between April 1999 and July 2002, the 8.2-m VLT ANTU telescope on Cerro Paranal in Chile) was operated in service mode on many occasions to obtain K-band images of the two fields in Centaurus A by means of the near-infrared ISAAC multi-mode instrument. Each field was observed over 20 times in the course of this three-year period ; some of the images were obtained during exceptional seeing conditions of 0.30 arcsec. One set of complementary optical images was obtained with the FORS1 multi-mode instrument (also on VLT ANTU) in July 1999. Each image from the ISAAC instrument covers a sky field measuring 2.5 x 2.5 arcmin 2. The combined images, encompassing a total exposure of 20 hours are indeed the deepest infrared images ever made of the halo of any galaxy as distant as Centaurus A , about 13 million light-years. Discovering one thousand Mira variables ESO PR Photo 14g/03 ESO PR Photo 14g/03 [Preview - JPEG: 400 x 480 pix - 61k [Normal - JPEG: 800 x 961 pix - 808k] ESO PR Photo 14h/03 ESO PR Photo 14h/03 [Animated GIF: 263 x 267 pix - 56k ESO PR Photo 14i/03 ESO PR Photo 14i/03 [Preview - JPEG: 480 x 400 pix - 33k [Normal - JPEG: 959 x 800 pix - 152k] Captions : PR Photo 14g/03 shows a zoomed-in area within "Field 2" in Centaurus A , from the ISAAC colour image shown in PR Photo 14e/03 . Nearly all red stars in this area are of the variable Mira-type. The brightness variation of some stars (labelled A-D) is demonstrated in the animated-GIF image PR Photo 14h/03 . The corresponding light curves (brightness over the pulsation period) are shown in PR Photo 14i/03 . Here the abscissa indicates the pulsation phase (one full period corresponds to the interval from 0 to 1) and the ordinate unit is near-infrared K s -magnitude. One magnitude corresponds to a difference in brightness of a factor 2.5. Once the lengthy observations were completed, two further steps were needed to identify the variable stars in Centaurus A . First, each ISAAC frame was individually processed to identify the thousands and thousands of faint point-like images (stars) visible in these fields. Next, all images were compared using a special software package ("DAOPHOT") to measure the brightness of all these stars in the different frames, i.e., as a function of time. While most stars in these fields as expected were found to have constant brightness, more than 1000 stars displayed variations in brightness with time; this is by far the largest number of variable stars ever discovered in a galaxy outside the Local Group of Galaxies. The detailed analysis of this enormous dataset took more than a year. Most of the variable stars were found to be of the Mira-type and their light curves (brightness over the pulsation period) were measured, cf. PR Photo 14i/03 . For each of them, values of the characterising parameters, the period (days) and brightness amplitude (magnitudes) were determined. A catalogue of the newly discovered variable stars in Centaurus A has now been made available to the astronomical community via the European research journal Astronomy & Astrophysics. Marina Rejkuba is pleased and thankful: "We are really very fortunate to have carried out this ambitious project so successfully. It all depended critically on different factors: the repeated granting of crucial observing time by the ESO Observing Programmes Committee over different observing periods in the face of rigorous international competition, the stability and reliability of the telescope and the ISAAC instrument over a period of more than three years and, not least, the excellent quality of the service mode observations, so efficiently performed by the staff at the Paranal Observatory." What have we learned about Centaurus A? The present study of variable stars in this giant elliptical galaxy is the first-ever of its kind. Although the evaluation of the very large observational data material is still not finished, it has already led to a number of very useful scientific results. Confirmation of the presence of an intermediate-age population Based on earlier research (optical and near-IR colour-magnitude diagrams of the stars in the fields), the present team of astronomers had previously detected the presence of intermediate-age and young stellar populations in the halo of this galaxy. The youngest stars appear to be aligned with the powerful jet produced by the massive black hole at the centre. Some of the very luminous red variable stars now discovered confirm the presence of a population of intermediate-age stars in the halo of this galaxy. It also contributes to our understanding of how giant elliptical galaxies form. New measurement of the distance to Centaurus A The pulsation of Mira-type variable stars obeys a period-luminosity relation. The longer its period, the more luminous is a Mira-type star. This fact makes it possible to use Mira-type stars as "standard candles" (objects of known intrinsic luminosity) for distance determinations. They have in fact often been used in this way to measure accurate distances to more nearby objects, e.g., to individual clusters of stars and to the center in our Milky Way galaxy, and also to galaxies in the Local Group, in particular the Magellanic Clouds. This method works particularly well with infrared measurements and the astronomers were now able to measure the distance to Centaurus A in this new way. They found 13.7 ± 1.9 million light-years , in general agreement with and thus confirming other methods. Study of stellar population gradients in the halo of a giant elliptical galaxy The two fields here studied contain different populations of stars. A clear dependence on the location (a "gradient") within the galaxy is observed, which can be due to differences in chemical composition or age, or to a combination of both. Understanding the cause of this gradient will provide additional clues to how Centaurus A - and indeed all giant elliptical galaxies - was formed and has since evolved. Comparison with other well-known nearby galaxies Past searches have discovered Mira-type variable stars thoughout the Milky Way, our home galaxy, and in other nearby galaxies in the Local Group. However, there are no giant elliptical galaxies like Centaurus A in the Local Group and this is the first time it has been possible to identify this kind of stars in that type of galaxy. The present investigation now opens a new window towards studies of the stellar constituents of such galaxies .
Azzouzi, Imane; Moest, Hansjoerg; Wollscheid, Bernd; Schmugge, Markus; Eekels, Julia J M; Speer, Oliver
2015-05-01
During maturation, erythropoietic cells extrude their nuclei but retain their ability to respond to oxidant stress by tightly regulating protein translation. Several studies have reported microRNA-mediated regulation of translation during terminal stages of erythropoiesis, even after enucleation. In the present study, we performed a detailed examination of the endogenous microRNA machinery in human red blood cells using a combination of deep sequencing analysis of microRNAs and proteomic analysis of the microRNA-induced silencing complex. Among the 197 different microRNAs detected, miR-451a was the most abundant, representing more than 60% of all read sequences. In addition, miR-451a and its known target, 14-3-3ζ mRNA, were bound to the microRNA-induced silencing complex, implying their direct interaction in red blood cells. The proteomic characterization of endogenous Argonaute 2-associated microRNA-induced silencing complex revealed 26 cofactor candidates. Among these cofactors, we identified several RNA-binding proteins, as well as motor proteins and vesicular trafficking proteins. Our results demonstrate that red blood cells contain complex microRNA machinery, which might enable immature red blood cells to control protein translation independent of de novo nuclei information. Copyright © 2015 ISEH - International Society for Experimental Hematology. Published by Elsevier Inc. All rights reserved.
Campbell, Graeme M; Sophocleous, Antonia
2014-01-01
Micro-computed tomography (micro-CT) is a high-resolution imaging modality that is capable of analysing bone structure with a voxel size on the order of 10 μm. With the development of in vivo micro-CT, where disease progression and treatment can be monitored in a living animal over a period of time, this modality has become a standard tool for preclinical assessment of bone architecture during disease progression and treatment. For meaningful comparison between micro-CT studies, it is essential that the same parameters for data acquisition and analysis methods be used. This protocol outlines the common procedures that are currently used for sample preparation, scanning, reconstruction and analysis in micro-CT studies. Scan and analysis methods for trabecular and cortical bone are covered for the femur, tibia, vertebra and the full neonate body of small rodents. The analysis procedures using the software provided by ScancoMedical and Bruker are discussed, and the routinely used bone architectural parameters are outlined. This protocol also provides a section dedicated to in vivo scanning and analysis, which covers the topics of anaesthesia, radiation dose and image registration. Because of the expanding research using micro-CT to study other skeletal sites, as well as soft tissues, we also provide a review of current techniques to examine the skull and mandible, adipose tissue, vasculature, tumour severity and cartilage. Lists of recommended further reading and literature references are included to provide the reader with more detail on the methods described. PMID:25184037
Micro-computed tomography of false starts produced on bone by different hand-saws.
Pelletti, Guido; Viel, Guido; Fais, Paolo; Viero, Alessia; Visentin, Sindi; Miotto, Diego; Montisci, Massimo; Cecchetto, Giovanni; Giraudo, Chiara
2017-05-01
The analysis of macro- and microscopic characteristics of saw marks on bones can provide useful information about the class of the tool utilized to produce the injury. The aim of the present study was to test micro-computed tomography (micro-CT) for the analysis of false starts experimentally produced on 32 human bone sections using 4 different hand-saws in order to verify the potential utility of micro-CT for distinguishing false starts produced by different saws and to correlate the morphology of the tool with that of the bone mark. Each sample was analysed through stereomicroscopy and micro-CT. Stereomicroscopic analysis allowed the identification of the false starts and the detection of the number of tool marks left by each saw. Micro-CT scans, through the integration of 3D renders and multiplanar reconstructions (MPR), allowed the identification of the shape of each false start correlating it to the injuring tool. Our results suggest that micro-CT could be a useful technique for assessing false starts produced by different classes of saws, providing accurate morphological profiles of the bone marks with all the advantages of high resolution 3D imaging (e.g., high accuracy, non-destructive analysis, preservation and documentation of evidence). However, further studies are necessary to integrate qualitative data with quantitative metrical analysis in order to further characterize the false start and the related injuring tool. Copyright © 2017 Elsevier B.V. All rights reserved.
miTRATA: a web-based tool for microRNA Truncation and Tailing Analysis.
Patel, Parth; Ramachandruni, S Deepthi; Kakrana, Atul; Nakano, Mayumi; Meyers, Blake C
2016-02-01
We describe miTRATA, the first web-based tool for microRNA Truncation and Tailing Analysis--the analysis of 3' modifications of microRNAs including the loss or gain of nucleotides relative to the canonical sequence. miTRATA is implemented in Python (version 3) and employs parallel processing modules to enhance its scalability when analyzing multiple small RNA (sRNA) sequencing datasets. It utilizes miRBase, currently version 21, as a source of known microRNAs for analysis. miTRATA notifies user(s) via email to download as well as visualize the results online. miTRATA's strengths lie in (i) its biologist-focused web interface, (ii) improved scalability via parallel processing and (iii) its uniqueness as a webtool to perform microRNA truncation and tailing analysis. miTRATA is developed in Python and PHP. It is available as a web-based application from https://wasabi.dbi.udel.edu/∼apps/ta/. meyers@dbi.udel.edu Supplementary data are available at Bioinformatics online. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Rubble-Pile Minor Planet Sylvia and Her Twins
NASA Astrophysics Data System (ADS)
2005-08-01
VLT NACO Instrument Helps Discover First Triple Asteroid One of the thousands of minor planets orbiting the Sun has been found to have its own mini planetary system. Astronomer Franck Marchis (University of California, Berkeley, USA) and his colleagues at the Observatoire de Paris (France) [1] have discovered the first triple asteroid system - two small asteroids orbiting a larger one known since 1866 as 87 Sylvia [2]. "Since double asteroids seem to be common, people have been looking for multiple asteroid systems for a long time," said Marchis. "I couldn't believe we found one." The discovery was made with Yepun, one of ESO's 8.2-m telescopes of the Very Large Telescope Array at Cerro Paranal (Chile), using the outstanding image' sharpness provided by the adaptive optics NACO instrument. Via the observatory's proven "Service Observing Mode", Marchis and his colleagues were able to obtain sky images of many asteroids over a six-month period without actually having to travel to Chile. ESO PR Photo 25a/05 ESO PR Photo 25a/05 Orbits of Twin Moonlets around 87 Sylvia [Preview - JPEG: 400 x 516 pix - 145k] [Normal - JPEG: 800 x 1032 pix - 350k] ESO PR Photo 25b/05 ESO PR Photo 25b/05 Artist's impression of the triple asteroid system [Preview - JPEG: 420 x 400 pix - 98k] [Normal - JPEG: 849 x 800 pix - 238k] [Full Res - JPEG: 4000 x 3407 pix - 3.7M] [Full Res - TIFF: 4000 x 3000 pix - 36.0M] Caption: ESO PR Photo 25a/05 is a composite image showing the positions of Remus and Romulus around 87 Sylvia on 9 different nights as seen on NACO images. It clearly reveals the orbits of the two moonlets. The inset shows the potato shape of 87 Sylvia. The field of view is 2 arcsec. North is up and East is left. ESO PR Photo 25b/05 is an artist rendering of the triple system: Romulus, Sylvia, and Remus. ESO Video Clip 03/05 ESO Video Clip 03/05 Asteroid Sylvia and Her Twins [Quicktime Movie - 50 sec - 384 x 288 pix - 12.6M] Caption: ESO PR Video Clip 03/05 is an artist rendering of the triple asteroid system showing the large asteroid 87 Sylvia spinning at a rapid rate and surrounded by two smaller asteroids (Remus and Romulus) in orbit around it. This computer animation is also available in broadcast quality to the media (please contact Herbert Zodet). One of these asteroids was 87 Sylvia, which was known to be double since 2001, from observations made by Mike Brown and Jean-Luc Margot with the Keck telescope. The astronomers used NACO to observe Sylvia on 27 occasions, over a two-month period. On each of the images, the known small companion was seen, allowing Marchis and his colleagues to precisely compute its orbit. But on 12 of the images, the astronomers also found a closer and smaller companion. 87 Sylvia is thus not double but triple! Because 87 Sylvia was named after Rhea Sylvia, the mythical mother of the founders of Rome [3], Marchis proposed naming the twin moons after those founders: Romulus and Remus. The International Astronomical Union approved the names. Sylvia's moons are considerably smaller, orbiting in nearly circular orbits and in the same plane and direction. The closest and newly discovered moonlet, orbiting about 710 km from Sylvia, is Remus, a body only 7 km across and circling Sylvia every 33 hours. The second, Romulus, orbits at about 1360 km in 87.6 hours and measures about 18 km across. The asteroid 87 Sylvia is one of the largest known from the asteroid main belt, and is located about 3.5 times further away from the Sun than the Earth, between the orbits of Mars and Jupiter. The wealth of details provided by the NACO images show that 87 Sylvia is shaped like a lumpy potato, measuring 380 x 260 x 230 km (see ESO PR Photo 25a/05). It is spinning at a rapid rate, once every 5 hours and 11 minutes. The observations of the moonlets' orbits allow the astronomers to precisely calculate the mass and density of Sylvia. With a density only 20% higher than the density of water, it is likely composed of water ice and rubble from a primordial asteroid. "It could be up to 60 percent empty space," said co-discoverer Daniel Hestroffer (Observatoire de Paris, France). "It is most probably a "rubble-pile" asteroid", Marchis added. These asteroids are loose aggregations of rock, presumably the result of a collision. Two asteroids smacked into each other and got disrupted. The new rubble-pile asteroid formed later by accumulation of large fragments while the moonlets are probably debris left over from the collision that were captured by the newly formed asteroid and eventually settled into orbits around it. "Because of the way they form, we expect to see more multiple asteroid systems like this." Marchis and his colleagues will report their discovery in the August 11 issue of the journal Nature, simultaneously with an announcement that day at the Asteroid Comet Meteor conference in Armação dos Búzios, Rio de Janeiro state, Brazil.
Guidelines for the functional annotation of microRNAs using the Gene Ontology
D'Eustachio, Peter; Smith, Jennifer R.; Zampetaki, Anna
2016-01-01
MicroRNA regulation of developmental and cellular processes is a relatively new field of study, and the available research data have not been organized to enable its inclusion in pathway and network analysis tools. The association of gene products with terms from the Gene Ontology is an effective method to analyze functional data, but until recently there has been no substantial effort dedicated to applying Gene Ontology terms to microRNAs. Consequently, when performing functional analysis of microRNA data sets, researchers have had to rely instead on the functional annotations associated with the genes encoding microRNA targets. In consultation with experts in the field of microRNA research, we have created comprehensive recommendations for the Gene Ontology curation of microRNAs. This curation manual will enable provision of a high-quality, reliable set of functional annotations for the advancement of microRNA research. Here we describe the key aspects of the work, including development of the Gene Ontology to represent this data, standards for describing the data, and guidelines to support curators making these annotations. The full microRNA curation guidelines are available on the GO Consortium wiki (http://wiki.geneontology.org/index.php/MicroRNA_GO_annotation_manual). PMID:26917558
Nuclear microscopy in trace-element biology — from cellular studies to the clinic
NASA Astrophysics Data System (ADS)
Lindh, Ulf
1993-05-01
The concentration and distribution of trace and major elements in cells are of great interest in cell biology. PIXE can provide elemental concentrations in the bulk of cells or organelles as other bulk techniques such as atomic absorption spectrophotometry and nuclear activation analysis. Supplementary information, perhaps more exciting, on the intracellular distributions of trace elements can be provided using nuclear microscopy. Intracellular distributions of trace elements in normal and malignant cells are presented. The toxicity of mercury and cadmium can be prevented by supplementation of the essential trace element selenium. Some results from an experimental animal model are discussed. The intercellular distribution of major and trace elements in isolated blood cells, as revealed by nuclear microscopy, provides useful clinical information. Examples are given concerning inflammatory connective-tissue diseases and the chronic fatigue syndrome.