Design of PID temperature control system based on STM32
NASA Astrophysics Data System (ADS)
Zhang, Jianxin; Li, Hailin; Ma, Kai; Xue, Liang; Han, Bianhua; Dong, Yuemeng; Tan, Yue; Gu, Chengru
2018-03-01
A rapid and high-accuracy temperature control system was designed using proportional-integral-derivative (PID) control algorithm with STM32 as micro-controller unit (MCU). The temperature control system can be applied in the fields which have high requirements on the response speed and accuracy of temperature control. The temperature acquisition circuit in system adopted Pt1000 resistance thermometer as temperature sensor. Through this acquisition circuit, the monitoring actual temperature signal could be converted into voltage signal and transmitted into MCU. A TLP521-1 photoelectric coupler was matched with BD237 power transistor to drive the thermoelectric cooler (TEC) in FTA951 module. The effective electric power of TEC was controlled by the pulse width modulation (PWM) signals which generated by MCU. The PWM signal parameters could be adjusted timely by PID algorithm according to the difference between monitoring actual temperature and set temperature. The upper computer was used to input the set temperature and monitor the system running state via serial port. The application experiment results show that the temperature control system is featured by simple structure, rapid response speed, good stability and high temperature control accuracy with the error less than ±0.5°C.
Zaglia, Tania; Ceriotti, Paola; Campo, Antonio; Borile, Giulia; Armani, Andrea; Carullo, Pierluigi; Prando, Valentina; Coppini, Raffaele; Vida, Vladimiro; Stølen, Tomas O.; Ulrik, Wisløff; Cerbai, Elisabetta; Stellin, Giovanni; Faggian, Giuseppe; De Stefani, Diego; Sandri, Marco; Rizzuto, Rosario; Di Lisa, Fabio; Pozzan, Tullio; Catalucci, Daniele; Mongillo, Marco
2017-01-01
The mitochondrial Ca2+ uniporter complex (MCUC) is a multimeric ion channel which, by tuning Ca2+ influx into the mitochondrial matrix, finely regulates metabolic energy production. In the heart, this dynamic control of mitochondrial Ca2+ uptake is fundamental for cardiomyocytes to adapt to either physiologic or pathologic stresses. Mitochondrial calcium uniporter (MCU), which is the core channel subunit of MCUC, has been shown to play a critical role in the response to β-adrenoreceptor stimulation occurring during acute exercise. The molecular mechanisms underlying the regulation of MCU, in conditions requiring chronic increase in energy production, such as physiologic or pathologic cardiac growth, remain elusive. Here, we show that microRNA-1 (miR-1), a member of the muscle-specific microRNA (myomiR) family, is responsible for direct and selective targeting of MCU and inhibition of its translation, thereby affecting the capacity of the mitochondrial Ca2+ uptake machinery. Consistent with the role of miR-1 in heart development and cardiomyocyte hypertrophic remodeling, we additionally found that MCU levels are inversely related with the myomiR content, in murine and, remarkably, human hearts from both physiologic (i.e., postnatal development and exercise) and pathologic (i.e., pressure overload) myocardial hypertrophy. Interestingly, the persistent activation of β-adrenoreceptors is likely one of the upstream repressors of miR-1 as treatment with β-blockers in pressure-overloaded mouse hearts prevented its down-regulation and the consequent increase in MCU content. Altogether, these findings identify the miR-1/MCU axis as a factor in the dynamic adaptation of cardiac cells to hypertrophy. PMID:29073097
Hong, Zhigang; Chen, Kuang-Hueih; DasGupta, Asish; Potus, Francois; Dunham-Snary, Kimberly; Bonnet, Sebastien; Tian, Lian; Fu, Jennifer; Breuils-Bonnet, Sandra; Provencher, Steeve; Wu, Danchen; Mewburn, Jeffrey; Ormiston, Mark L.
2017-01-01
Rationale: Pulmonary arterial hypertension (PAH) is an obstructive vasculopathy characterized by excessive pulmonary artery smooth muscle cell (PASMC) proliferation, migration, and apoptosis resistance. This cancer-like phenotype is promoted by increased cytosolic calcium ([Ca2+]cyto), aerobic glycolysis, and mitochondrial fission. Objectives: To determine how changes in mitochondrial calcium uniporter (MCU) complex (MCUC) function influence mitochondrial dynamics and contribute to PAH’s cancer-like phenotype. Methods: PASMCs were isolated from patients with PAH and healthy control subjects and assessed for expression of MCUC subunits. Manipulation of the pore-forming subunit, MCU, in PASMCs was achieved through small interfering RNA knockdown or MCU plasmid-mediated up-regulation, as well as through modulation of the upstream microRNAs (miRs) miR-138 and miR-25. In vivo, nebulized anti-miRs were administered to rats with monocrotaline-induced PAH. Measurements and Main Results: Impaired MCUC function, resulting from down-regulation of MCU and up-regulation of an inhibitory subunit, mitochondrial calcium uptake protein 1, is central to PAH’s pathogenesis. MCUC dysfunction decreases intramitochondrial calcium ([Ca2+]mito), inhibiting pyruvate dehydrogenase activity and glucose oxidation, while increasing [Ca2+]cyto, promoting proliferation, migration, and fission. In PAH PASMCs, increasing MCU decreases cell migration, proliferation, and apoptosis resistance by lowering [Ca2+]cyto, raising [Ca2+]mito, and inhibiting fission. In normal PASMCs, MCUC inhibition recapitulates the PAH phenotype. In PAH, elevated miRs (notably miR-138) down-regulate MCU directly and also by decreasing MCU’s transcriptional regulator cAMP response element–binding protein 1. Nebulized anti-miRs against miR-25 and miR-138 restore MCU expression, reduce cell proliferation, and regress established PAH in the monocrotaline model. Conclusions: These results highlight miR-mediated MCUC dysfunction as a unifying mechanism in PAH that can be therapeutically targeted. PMID:27648837
Vibration condition measure instrument of motor using MEMS accelerometer
NASA Astrophysics Data System (ADS)
Chen, Jun
2018-04-01
In this work, a novel vibration condition measure instrument of motor using a digital micro accelerometer is proposed. In order to reduce the random noise found in the data, the sensor modeling is established and also the Kalman filter (KMF) is developed. According to these data from KMF, the maximum vibration displacement is calculated by the integration algorithm with the DC bias removed. The high performance micro controller unit (MCU) is used in the implementation of controller. By the IIC digital interface port, the data are transmitted from sensor to controller. The hardware circuits of the sensor and micro controller are designed and tested. With the computational formula of maximum displacement and FFT, the high precession results of displacement and frequency are gotten. Finally, the paper presents various experimental results to prove that this instrument is suitable for application in electrical motor vibration measurement.
A 1000+ channel bionic communication system.
Schulman, Joseph H; Mobley, J Phil; Wolfe, James; Stover, Howard; Krag, Adrian
2006-01-01
The wireless electronic nervous system interface known as the functional electrical stimulation-battery powered bion system is being developed at the Alfred Mann Foundation. It contains a real-time propagated wave micro-powered multichannel communication system. This system is designed to send bi-directional messages between an external master controller unit (MCU), and each one of a group of injectable stimulator-sensor battery powered bion implants (BPB). The system is capable of communicating in each direction about 90 times per second using a structure of 850 time slots within a repeating 11 millisecond time window. The system's total Time Division Multiple Access (TDMA) communication capability is about 77,000 two-way communications per second on a single 5 MHz wide radio channel. Each time slot can be used by one BPB, or shared alternately by two or more BPBs. Each bidirectional communication consists of a 15 data bit message sent from the MCU sequentially to each BPB and 10 data bit message sent sequentially from each BPB to the MCU. Redundancy bits are included to provide error detection and correction. This communication system is designed to draw only a few microamps from the 3.6 volt, 3.0 mAHr lithium ion (LiIon) battery contained in each BPB, and the majority of the communications circuitry is contained within a 1.4x5 mm integrated circuit.
NASA Astrophysics Data System (ADS)
Yu, Yanan; Wang, Xiaoxun; He, Chengcheng; Lai, Chenlong; Liu, Yuanchao
2015-11-01
For overcoming the problems such as remote operation and dangerous tasks, multi-terminal remote monitoring and warning system based on STC89C52 Micro Control Unit and wireless communication technique was proposed. The system with MCU as its core adopted multiple sets of sensor device to monitor environment parameters of different locations, such as temperature, humidity, smoke other harmful gas concentration. Data information collected was transmitted remotely by wireless transceiver module, and then multi-channel data parameter was processed and displayed through serial communication protocol between the module and PC. The results of system could be checked in the form of web pages within a local network which plays a wireless monitoring and warning role. In a remote operation, four-rotor micro air vehicle which fixed airborne data acquisition device was utilized as a middleware between collecting terminal and PC to increase monitoring scope. Whole test system has characteristics of simple construction, convenience, real time ability and high reliability, which could meet the requirements of actual use.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, T.; Washington, A; . Fondeur, F.
2011-09-29
Savannah River National Laboratory (SRNL) periodically analyses solvent samples from Modular Caustic-Side Solvent Extraction Unit (MCU) in support of continuing operations. A quarterly analysis of the solvent is required to maintain solvent composition within specifications. Analytical results of the analyses of Solvent Hold Tank (SHT) samples MCU-11-314, MCU-11-315, MCU-11-316, MCU-11-317, MCU-11-318 and MCU-11-319 have been previously reported. MCU has experienced a modest decline in cesium removal efficiency while processing the current feed, 'Macrobatch 3'. While the target decontamination factor (DF) is 200, the fiscal year 2011 DF average is 161. The results of the prior solvent analysis report did notmore » identify a specific factor that would correlate with the poor cesium decontamination beyond a low concentration of the suppressor, trioctylamine. New analyses of the quarterly sample are reported in this document, as well as a cross-check of {sup 137}Cs measurements for SRNL and F/H lab. Furthermore, in an attempt to discover the reason for the decline in DF at MCU, SRNL was tasked with analyzing numerous Caustic Wash Tank (CWT) and chemical feed samples.« less
Design of light-small high-speed image data processing system
NASA Astrophysics Data System (ADS)
Yang, Jinbao; Feng, Xue; Li, Fei
2015-10-01
A light-small high speed image data processing system was designed in order to meet the request of image data processing in aerospace. System was constructed of FPGA, DSP and MCU (Micro-controller), implementing a video compress of 3 million pixels@15frames and real-time return of compressed image to the upper system. Programmable characteristic of FPGA, high performance image compress IC and configurable MCU were made best use to improve integration. Besides, hard-soft board design was introduced and PCB layout was optimized. At last, system achieved miniaturization, light-weight and fast heat dispersion. Experiments show that, system's multifunction was designed correctly and worked stably. In conclusion, system can be widely used in the area of light-small imaging.
Assessment of the impact of the next generation solvent on DWPF melter off-gas flammability
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daniel, W. E.
2013-02-13
An assessment has been made to evaluate the impact on the DWPF melter off-gas flammability of replacing the current solvent used in the Modular Caustic-Side Solvent Extraction Process Unit (MCU) process with the Next Generation Solvent (NGS-MCU) and blended solvent. The results of this study showed that the concentrations of nonvolatile carbon and hydrogen of the current solvent in the Slurry Mix Evaporator (SME) product would both be about 29% higher than their counterparts of the NGS-MCU and blended solvent in the absence of guanidine partitioning. When 6 ppm of guanidine (TiDG) was added to the effluent transfer to DWPFmore » to simulate partitioning for the NGS-MCU and blended solvent cases and the concentration of Isopar{reg_sign} L in the effluent transfer was controlled below 87 ppm, the concentrations of nonvolatile carbon and hydrogen of the NGS-MCU and blended solvent were still about 12% and 4% lower, respectively, than those of the current solvent. It is, therefore, concluded that as long as the volume of MCU effluent transfer to DWPF is limited to 15,000 gallons per Sludge Receipt and Adjustment Tank (SRAT)/SME cycle and the concentration of Isopar{reg_sign} L in the effluent transfer is controlled below 87 ppm, using the current solvent assumption of 105 ppm Isopar{reg_sign} L or 150 ppm solvent in lieu of NGS-MCU or blended solvent in the DWPF melter off-gas flammability assessment is conservative for up to an additional 6 ppm of TiDG in the effluent due to guanidine partitioning. This report documents the calculations performed to reach this conclusion.« less
NASA Astrophysics Data System (ADS)
Natsui, Masanori; Hanyu, Takahiro
2018-04-01
In realizing a nonvolatile microcontroller unit (MCU) for sensor nodes in Internet-of-Things (IoT) applications, it is important to solve the data-transfer bottleneck between the central processing unit (CPU) and the nonvolatile memory constituting the MCU. As one circuit-oriented approach to solving this problem, we propose a memory access minimization technique for magnetoresistive-random-access-memory (MRAM)-embedded nonvolatile MCUs. In addition to multiplexing and prefetching of memory access, the proposed technique realizes efficient instruction fetch by eliminating redundant memory access while considering the code length of the instruction to be fetched and the transition of the memory address to be accessed. As a result, the performance of the MCU can be improved while relaxing the performance requirement for the embedded MRAM, and compact and low-power implementation can be performed as compared with the conventional cache-based one. Through the evaluation using a system consisting of a general purpose 32-bit CPU and embedded MRAM, it is demonstrated that the proposed technique increases the peak efficiency of the system up to 3.71 times, while a 2.29-fold area reduction is achieved compared with the cache-based one.
Rudolph, P; Isensee, D; Gerlach, E; Gross, H
2013-02-01
The question of whether a medical care unit is an appropriate tool for outpatient care has been discussed for a long time. Our aim is to investigate whether the MCU is an effective instrument for outpatient care and adequate performance-related remuneration. This retro- and prospective overview of the work included statements on legal foundations for medical care units, for reimbursement of services in medical care units, the development of medical care centres in Germany and a listing of the specific advantages and disadvantages of an MCU. This article focuses on the generally applicable facts and complements them with examples from general, visceral and vascular surgery. The main quantitative data on medical centre statistics come from different publications of the National Association of Statutory Health Insurance for Physicians. From a legal point of view the instrument MCU allows the participating of ambulatory and stationary care in the framework of medical care contracts. This has been especially extended for stationary applications, including the spectrum of possibilities that can contribute under certain circumstances for the provision of medical care in underdeveloped regions. Freelancers can benefit primarily from financial risk and minimising bureaucratic routine. The remuneration for services performed in the MCU is analogous to that of other ambulatory care providers. Basically, there are no disadvantages, but a greater design freedom and opportunities for the generation of aggregates are visible. The number of MCU in Germany has quadrupled in the last five years, indicating an establishment of an outpatient care landscape. MCU offers from the patient's perspective, providers and policy specific advantages and disadvantages. Indeed the benefits outweigh the disadvantages, but this is not yet verified by qualitative studies. The question of the appropriateness of medical care units as outpatient care instrumentation must be considered differentially. Under current conditions it appears suitable for ensuring the MCU and the supplement of care supply. Whether a value can be generated in the quality of care of patients, however, has to be examined separately, as there are no valid data so far. The same applies to economic assessments of costs and benefits from an economic perspective. © Georg Thieme Verlag KG Stuttgart · New York.
Chen, Chiung-An; Chen, Shih-Lun; Huang, Hong-Yi; Luo, Ching-Hsing
2012-11-22
In this paper, a low-cost, low-power and high performance micro control unit (MCU) core is proposed for wireless body sensor networks (WBSNs). It consists of an asynchronous interface, a register bank, a reconfigurable filter, a slop-feature forecast, a lossless data encoder, an error correct coding (ECC) encoder, a UART interface, a power management (PWM), and a multi-sensor controller. To improve the system performance and expansion abilities, the asynchronous interface is added for handling signal exchanges between different clock domains. To eliminate the noise of various bio-signals, the reconfigurable filter is created to provide the functions of average, binomial and sharpen filters. The slop-feature forecast and the lossless data encoder is proposed to reduce the data of various biomedical signals for transmission. Furthermore, the ECC encoder is added to improve the reliability for the wireless transmission and the UART interface is employed the proposed design to be compatible with wireless devices. For long-term healthcare monitoring application, a power management technique is developed for reducing the power consumption of the WBSN system. In addition, the proposed design can be operated with four different bio-sensors simultaneously. The proposed design was successfully tested with a FPGA verification board. The VLSI architecture of this work contains 7.67-K gate counts and consumes the power of 5.8 mW or 1.9 mW at 100 MHz or 133 MHz processing rate using a TSMC 0.18 μm or 0.13 μm CMOS process. Compared with previous techniques, this design achieves higher performance, more functions, more flexibility and higher compatibility than other micro controller designs.
A design of LED adaptive dimming lighting system based on incremental PID controller
NASA Astrophysics Data System (ADS)
He, Xiangyan; Xiao, Zexin; He, Shaojia
2010-11-01
As a new generation energy-saving lighting source, LED is applied widely in various technology and industry fields. The requirement of its adaptive lighting technology is more and more rigorous, especially in the automatic on-line detecting system. In this paper, a closed loop feedback LED adaptive dimming lighting system based on incremental PID controller is designed, which consists of MEGA16 chip as a Micro-controller Unit (MCU), the ambient light sensor BH1750 chip with Inter-Integrated Circuit (I2C), and constant-current driving circuit. A given value of light intensity required for the on-line detecting environment need to be saved to the register of MCU. The optical intensity, detected by BH1750 chip in real time, is converted to digital signal by AD converter of the BH1750 chip, and then transmitted to MEGA16 chip through I2C serial bus. Since the variation law of light intensity in the on-line detecting environment is usually not easy to be established, incremental Proportional-Integral-Differential (PID) algorithm is applied in this system. Control variable obtained by the incremental PID determines duty cycle of Pulse-Width Modulation (PWM). Consequently, LED's forward current is adjusted by PWM, and the luminous intensity of the detection environment is stabilized by self-adaptation. The coefficients of incremental PID are obtained respectively after experiments. Compared with the traditional LED dimming system, it has advantages of anti-interference, simple construction, fast response, and high stability by the use of incremental PID algorithm and BH1750 chip with I2C serial bus. Therefore, it is suitable for the adaptive on-line detecting applications.
The mitochondrial uniporter controls fight or flight heart rate increases.
Wu, Yuejin; Rasmussen, Tyler P; Koval, Olha M; Joiner, Mei-Ling A; Hall, Duane D; Chen, Biyi; Luczak, Elizabeth D; Wang, Qiongling; Rokita, Adam G; Wehrens, Xander H T; Song, Long-Sheng; Anderson, Mark E
2015-01-20
Heart rate increases are a fundamental adaptation to physiological stress, while inappropriate heart rate increases are resistant to current therapies. However, the metabolic mechanisms driving heart rate acceleration in cardiac pacemaker cells remain incompletely understood. The mitochondrial calcium uniporter (MCU) facilitates calcium entry into the mitochondrial matrix to stimulate metabolism. We developed mice with myocardial MCU inhibition by transgenic expression of a dominant-negative (DN) MCU. Here, we show that DN-MCU mice had normal resting heart rates but were incapable of physiological fight or flight heart rate acceleration. We found that MCU function was essential for rapidly increasing mitochondrial calcium in pacemaker cells and that MCU-enhanced oxidative phoshorylation was required to accelerate reloading of an intracellular calcium compartment before each heartbeat. Our findings show that MCU is necessary for complete physiological heart rate acceleration and suggest that MCU inhibition could reduce inappropriate heart rate increases without affecting resting heart rate.
NASA Astrophysics Data System (ADS)
Hou, Ligang; Luo, Rengui; Wu, Wuchen
2006-11-01
This paper forwards a low power grating detection chip (EYAS) on length and angle precision measurement. Traditional grating detection method, such as resister chain divide or phase locked divide circuit are difficult to design and tune. The need of an additional CPU for control and display makes these methods' implementation more complex and costly. Traditional methods also suffer low sampling speed for the complex divide circuit scheme and CPU software compensation. EYAS is an application specific integrated circuit (ASIC). It integrates micro controller unit (MCU), power management unit (PMU), LCD controller, Keyboard interface, grating detection unit and other peripherals. Working at 10MHz, EYAS can afford 5MHz internal sampling rate and can handle 1.25MHz orthogonal signal from grating sensor. With a simple control interface by keyboard, sensor parameter, data processing and system working mode can be configured. Two LCD controllers can adapt to dot array LCD or segment bit LCD, which comprised output interface. PMU alters system between working and standby mode by clock gating technique to save power. EYAS in test mode (system action are more frequently than real world use) consumes 0.9mw, while 0.2mw in real world use. EYAS achieved the whole grating detection system function, high-speed orthogonal signal handling in a single chip with very low power consumption.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bannochie, C. J.
2015-09-17
The Savannah River National Laboratory (SRNL) was tasked with preparing and shipping samples for Hg speciation by Eurofins Frontier Global Sciences, Inc. in Seattle, WA on behalf of the Savannah River Remediation (SRR) Mercury Task Team.i,ii The tenth shipment of samples was designated to include Modular Caustic Side Solvent Extraction Unit (MCU) Strip Effluent Hold Tank (SEHT) and MCU Decontaminated Salt Solution Hold Tank (DSSHT) materials from processing Salt Batch 7b. The MCU SEHT (MCU-15-722) and DSSHT (MCU-15-709) samples were pulled on June 15, 2015. All MCU samples were received at SRNL on June 16, 2015. The DSSHT sample wasmore » moved the same day to refrigeration, while the SEHT sample was placed in the Shielded Cells. On July 9, 2015 it was opened and an aliquot diluted 1:100 with Eurofins deionized water and a portion of the diluted sample transferred to a Teflon® bottle prior to moving it to refrigeration that same day. All samples were kept in the dark and refrigerated until final dilutions were prepared for shipment to Eurofins.« less
NASA Astrophysics Data System (ADS)
Tapani Nikkanen, Timo; Schmidt, Walter; Genzer, Maria; Harri, Ari-Matti; Haukka, Harri
2013-04-01
The European Space Agency (ESA), driven by the goal of performing a soft landing on Mars, is planning to launch the Entry, descent and landing Demonstrator Module (EDM)[1] simultaneously with the Trace Gas Orbiter (TGO) as a part of the ExoMars program towards Mars in 2016. As a secondary objective, the EDM will gather meteorological data and observe the electrical environment of the landing site with its Dust characterisation, Risk assessment, and Environmental Analyser on the Martian Surface (DREAMS). The Finnish Meteorological Institute (FMI) is participating in the project by designing, building and testing a pressure and a humidity instrument for Mars, named DREAMS-P and DREAMS-H, respectively. The instruments are based on previous FMI designs, including ones flown on board the Huygens, Phoenix and Mars Science Laboratory.[2] Traditionally, the FMI pressure and humidity instruments have been controlled by an FPGA. However, the need to incorporate more autonomy and modifiability into instruments, cut the development time and component costs, stimulated interest to study a Commercial Off-The-Shelf (COTS) Microcontroller Unit (MCU) based instrument design. Thus, in the DREAMS-P/H design, an automotive MCU is used as the instrument controller. The MCU has been qualified for space by tests in and outside FMI. The DREAMS-P/H controller command and data interface utilizes a RS-422 connection to receive telecommands from and to transmit data to the Central Electronics Unit (CEU) of the DREAMS science package. The two pressure transducers of DREAMS-P and one humidity transducer of DREAMS-H are controlled by a single MCU. The MCU controls the power flow for each transducer and performs pulse counting measurements on sensor and reference channels to retrieve scientific data. Pressure and humidity measurements are scheduled and set up according to a configuration table assigned to each transducer. The configuration tables can be modified during the flight. The whole software is entirely interrupt driven, thus the MCU goes into a power saving standby mode whenever possible. Any measurement or other operation can be stopped by simply interrupting the controller with a telecommand. Software and functional tests of the DREAMS-P/H controller are needed to verify the performance of the instrument in nominal conditions and the correct operation and error detection in anomalous conditions. The nominal conditions tests range from simple functional and performance tests, to longer simulations of continued operation and measurements. Continued operation simulations can be implemented by executing accelerated runs of the expected normal measurement cycles. On the contrary, anomalous conditions tests are used to verify that the controller can handle bad telecommands or anomalous operation of the instrument transducers, for example in the case of malfunctioning sensors. Bad telecommand tests are done by feeding illegal parameters or scrambled telecommands to the controller. Malfunctioning sensors can be simulated by modifying the signals coming from the sensors and reference channels. All expected use cases and all imagined unexpected operating circumstances are studied to ensure that the system is robust. This also makes the planned modification of the design for other future missions easier and safer. Reference: [1] ESA ExoMars EDM mission: http://exploration.esa.int/science-e/www/object/index.cfm?fobjectid=47852 [2] FMI Space Projects website: http://space.fmi.fi/index.php?id=23
The Function of the Mitochondrial Calcium Uniporter in Neurodegenerative Disorders
Liao, Yajin; Dong, Yuan; Cheng, Jinbo
2017-01-01
The mitochondrial calcium uniporter (MCU)—a calcium uniporter on the inner membrane of mitochondria—controls the mitochondrial calcium uptake in normal and abnormal situations. Mitochondrial calcium is essential for the production of adenosine triphosphate (ATP); however, excessive calcium will induce mitochondrial dysfunction. Calcium homeostasis disruption and mitochondrial dysfunction is observed in many neurodegenerative disorders. However, the role and regulatory mechanism of the MCU in the development of these diseases are obscure. In this review, we summarize the role of the MCU in controlling oxidative stress-elevated mitochondrial calcium and its function in neurodegenerative disorders. Inhibition of the MCU signaling pathway might be a new target for the treatment of neurodegenerative disorders. PMID:28208618
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhao, Lantao; Li, Shuhong; Wang, Shilei, E-mail: wshlei@aliyun.com
The mitochondrial calcium uniporter (MCU) transports free Ca{sup 2+} into the mitochondrial matrix, maintaining Ca{sup 2+} homeostasis, thus regulates the mitochondrial morphology. Previous studies have indicated that there was closely crosstalk between MCU and mitochondrial fission during the process of ischemia/reperfusion injury. This study constructed a hypoxia reoxygenation model using primary hippocampus neurons to mimic the cerebral ischemia/reperfusion injury and aims to explore the exactly effect of MCU on the mitochondrial fission during the process of ischemia/reperfusion injury and so as the mechanisms. Our results found that the inhibitor of the MCU, Ru360, decreased mitochondrial Ca{sup 2+} concentration, suppressed themore » expression of mitochondrial fission protein Drp1, MIEF1 and Fis1, and thus improved mitochondrial morphology significantly. Whereas spermine, the agonist of the MCU, had no significant impact compared to the I/R group. This study demonstrated that the MCU regulates the process of mitochondrial fission by controlling the Ca{sup 2+} transport, directly upregulating mitochondrial fission proteins Drp1, Fis1 and indirectly reversing the MIEF1-induced mitochondrial fusion. It also provides new targets for brain protection during ischemia/reperfusion injury. - Highlights: • We study MCU with primary neuron culture. • MCU induces mitochondrial fission. • MCU reverses MIEF1 effect.« less
An Energy-Efficient ASIC for Wireless Body Sensor Networks in Medical Applications.
Xiaoyu Zhang; Hanjun Jiang; Lingwei Zhang; Chun Zhang; Zhihua Wang; Xinkai Chen
2010-02-01
An energy-efficient application-specific integrated circuit (ASIC) featured with a work-on-demand protocol is designed for wireless body sensor networks (WBSNs) in medical applications. Dedicated for ultra-low-power wireless sensor nodes, the ASIC consists of a low-power microcontroller unit (MCU), a power-management unit (PMU), reconfigurable sensor interfaces, communication ports controlling a wireless transceiver, and an integrated passive radio-frequency (RF) receiver with energy harvesting ability. The MCU, together with the PMU, provides quite flexible communication and power-control modes for energy-efficient operations. The always-on passive RF receiver with an RF energy harvesting block offers the sensor nodes the capability of work-on-demand with zero standby power. Fabricated in standard 0.18-¿m complementary metal-oxide semiconductor technology, the ASIC occupies a die area of 2 mm × 2.5 mm. A wireless body sensor network sensor-node prototype using this ASIC only consumes < 10-nA current under the passive standby mode, and < 10 ¿A under the active standby mode, when supplied by a 3-V battery.
The design of liquid drip speed monitoring device system based on MCU
NASA Astrophysics Data System (ADS)
Zheng, Shiyong; Li, Zhao; Li, Biqing
2017-08-01
This page proposed an intelligent transfusion control and monitoring system which designed by using AT89S52 micro controller as the core, using the keyboard and photoelectric sensor as the input module, digital tube and motor as the output module. The keyboard is independent and photoelectric sensor can offer reliable detection for liquid drop speed and the transfusion bottle page. When the liquid amount is less than the warning value, the system sounded the alarm, you can remove the alert by hand movement. With the advantages of speed controllable and input pulse power can be maintained of the motor, the system can control the bottle through the upper and lower slow-moving liquid drip to control the speed of intelligent purpose.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fondeur, F.; Jones, D.
SRNL received one set of SHT samples (MCU-16-991, MCU-16-992 and MCU-16-993), pulled on 07/13/2016 and another set of SHT samples (MCU-16-1033, MCU-16-1034, and MCU-16-1035) that were pulled on 07/24/2016 after the solvent was superwashed with 300 mM sodium hydroxide for analysis. Samples MCU-16-991, MCU-16-992, and MCU-16-993 were combined into one sample (MCU-16-991-992-993) and samples MCU-16-1033, MCU-16-1034, and MCU-16-1035 were combined into one sample (MCU-16-1033-1034-1035). Of the two composite samples MCU-16-1033-1034-1035 represents the current chemical state of the solvent at MCU. All analytical conclusions are based on the chemical analysis of MCU-16-1033-1034-1035. There were no chemical differences between MCU-16- 991-992-993 andmore » superwashed MCU-16-1033-1034-1035.« less
Designing low cost LED display for the billboard
NASA Astrophysics Data System (ADS)
Hong, Yi-Jian; Uang, Chii-Maw; Wang, Ping-Chieh; Ho, Zu-Sheng
2011-10-01
With quickly advance of the computer, microelectronics and photonics technologies, LED display panel becomes a new electronic advertising media. It can be used to show any information whatever characters or graphics. Most LED display panels are built of many Light-Emitting Diodes arranged in a matrix form. The display has many advantages such as low power, low cost, long life and high definition. Because the display panel is asked to show rich color, the LED display panel's driving system becomes very complex. The design methodology of LED display panel's driver becomes more and more important to meet the market requirements. Cost is always the most important issue in public market domain. In this paper, we report a design methodology of LED display panel's driver based on the microprocessor control unit (MCU) system and LED display controller IC, HT1632C, to control three colors, RGB, color LED display panel and the modular panel size is 24*16 in matrix form. The HT1632C is a memory mapping LED display controller, it can be used on many applications, such as digital clock, thermometer, counter, voltmeter or other instrumentation readouts. Three pieces of HT1632C are used to drive a 24*16 RGB LED display panel, in our design case. Each HT163C chip is used to control one of the R, G and B color. As the drive mode is driven in DC mode, the RGB display panel can create and totally of seven colors under the control of MCU. The MCU generates the control signal to drive HT1632C. In this study, the software design methodology is adopted with dynamic display principle. When the scan frequency is 60Hz, LED display panel will get the clear picture and be able to display seven colors.
Mitchell, T
2013-07-01
There is a drive in the UK to revise chemotherapy provision for people living in rural communities. Using a different model of treatment delivery might impact positively upon the experience of receiving chemotherapy. In 2007 the first nurse-led mobile chemotherapy unit (MCU) in the UK was launched in the South West of England with the intention of providing treatment closer to home. The aim of the research was to explore experiences of people with cancer who received chemotherapy treatment in outpatient clinic and/or onboard the MCU using an interpretive phenomenological approach. Interviews were conducted with 20 people and data were interpreted using thematic analysis. The cancer and chemotherapy journey was described as being undertaken by the participant and their significant other. Available car parking and travelling impacted upon quality of life, as did the environment and accessibility of nurses to discuss issues with participants. The most important, distinguishing feature between receiving chemotherapy in outpatient clinic and the MCU was the amount of time spent waiting. Having treatment on the MCU was perceived to be less formal and therefore less stressful. Participants reported significant savings in time spent travelling, waiting and having treatment, expenditure on fuel and companion costs. © 2013 John Wiley & Sons Ltd.
Patron, Maria; Checchetto, Vanessa; Raffaello, Anna; Teardo, Enrico; Vecellio Reane, Denis; Mantoan, Maura; Granatiero, Veronica; Szabò, Ildikò; De Stefani, Diego; Rizzuto, Rosario
2014-01-01
Summary Mitochondrial calcium accumulation was recently shown to depend on a complex composed of an inner-membrane channel (MCU and MCUb) and regulatory subunits (MICU1, MCUR1, and EMRE). A fundamental property of MCU is low activity at resting cytosolic Ca2+ concentrations, preventing deleterious Ca2+ cycling and organelle overload. Here we demonstrate that these properties are ensured by a regulatory heterodimer composed of two proteins with opposite effects, MICU1 and MICU2, which, both in purified lipid bilayers and in intact cells, stimulate and inhibit MCU activity, respectively. Both MICU1 and MICU2 are regulated by calcium through their EF-hand domains, thus accounting for the sigmoidal response of MCU to [Ca2+] in situ and allowing tight physiological control. At low [Ca2+], the dominant effect of MICU2 largely shuts down MCU activity; at higher [Ca2+], the stimulatory effect of MICU1 allows the prompt response of mitochondria to Ca2+ signals generated in the cytoplasm. PMID:24560927
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fondeur, F. F.; Jones, D. H.
The Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-16-701, MCU-16-702 and MCU-16-703), pulled on 05/23/2016, and another set of SHT samples (MCU-16-710, MCU-16-711, and MCU-16-712) were pulled on 05/28/2016 after the solvent was superwashed with 300 mM sodium hydroxide for analysis. Samples MCU-16-701, MCU-16-702, and MCU-16-703 were combined into one sample (MCU-16-701-702-703) and samples MCU-16-710, MCU- 16-711, and MCU-16-712 were combined into one sample (MCU-16-710-711-712). Of the two composite samples MCU-16-710-711-712 represents the current chemical state of the solvent at MCU. All analytical conclusions are based on the chemical analysis of MCU-16-710-711-712. Theremore » were no chemical differences between MCU-16-701-702-703 and superwashed MCU-16-710-711-712. Analysis of the composited sample MCU-16-710-712-713 indicated the Isopar™L concentration is above its nominal level (102%). The modifier (CS-7SB) is 16% below its nominal concentration, while the TiDG and MaxCalix concentrations are at and above their nominal concentrations, respectively. The TiDG level has begun to decrease, and it is 7% below its nominal level as of May 28, 2016. Based on this current analysis, the levels of TiDG, Isopar™L, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterization and trimming additions to the solvent are recommended.« less
Dynamic Synchronous Capture Algorithm for an Electromagnetic Flowmeter.
Fanjiang, Yong-Yi; Lu, Shih-Wei
2017-04-10
This paper proposes a dynamic synchronous capture (DSC) algorithm to calculate the flow rate for an electromagnetic flowmeter. The characteristics of the DSC algorithm can accurately calculate the flow rate signal and efficiently convert an analog signal to upgrade the execution performance of a microcontroller unit (MCU). Furthermore, it can reduce interference from abnormal noise. It is extremely steady and independent of fluctuations in the flow measurement. Moreover, it can calculate the current flow rate signal immediately (m/s). The DSC algorithm can be applied to the current general MCU firmware platform without using DSP (Digital Signal Processing) or a high-speed and high-end MCU platform, and signal amplification by hardware reduces the demand for ADC accuracy, which reduces the cost.
Dynamic Synchronous Capture Algorithm for an Electromagnetic Flowmeter
Fanjiang, Yong-Yi; Lu, Shih-Wei
2017-01-01
This paper proposes a dynamic synchronous capture (DSC) algorithm to calculate the flow rate for an electromagnetic flowmeter. The characteristics of the DSC algorithm can accurately calculate the flow rate signal and efficiently convert an analog signal to upgrade the execution performance of a microcontroller unit (MCU). Furthermore, it can reduce interference from abnormal noise. It is extremely steady and independent of fluctuations in the flow measurement. Moreover, it can calculate the current flow rate signal immediately (m/s). The DSC algorithm can be applied to the current general MCU firmware platform without using DSP (Digital Signal Processing) or a high-speed and high-end MCU platform, and signal amplification by hardware reduces the demand for ADC accuracy, which reduces the cost. PMID:28394306
Rasmussen, Tyler P.; Wu, Yuejin; Joiner, Mei-ling A.; Koval, Olha M.; Wilson, Nicholas R.; Luczak, Elizabeth D.; Wang, Qinchuan; Chen, Biyi; Gao, Zhan; Zhu, Zhiyong; Wagner, Brett A.; Soto, Jamie; McCormick, Michael L.; Kutschke, William; Weiss, Robert M.; Yu, Liping; Boudreau, Ryan L.; Abel, E. Dale; Zhan, Fenghuang; Spitz, Douglas R.; Buettner, Garry R.; Song, Long-Sheng; Zingman, Leonid V.; Anderson, Mark E.
2015-01-01
Myocardial mitochondrial Ca2+ entry enables physiological stress responses but in excess promotes injury and death. However, tissue-specific in vivo systems for testing the role of mitochondrial Ca2+ are lacking. We developed a mouse model with myocardial delimited transgenic expression of a dominant negative (DN) form of the mitochondrial Ca2+ uniporter (MCU). DN-MCU mice lack MCU-mediated mitochondrial Ca2+ entry in myocardium, but, surprisingly, isolated perfused hearts exhibited higher O2 consumption rates (OCR) and impaired pacing induced mechanical performance compared with wild-type (WT) littermate controls. In contrast, OCR in DN-MCU–permeabilized myocardial fibers or isolated mitochondria in low Ca2+ were not increased compared with WT, suggesting that DN-MCU expression increased OCR by enhanced energetic demands related to extramitochondrial Ca2+ homeostasis. Consistent with this, we found that DN-MCU ventricular cardiomyocytes exhibited elevated cytoplasmic [Ca2+] that was partially reversed by ATP dialysis, suggesting that metabolic defects arising from loss of MCU function impaired physiological intracellular Ca2+ homeostasis. Mitochondrial Ca2+ overload is thought to dissipate the inner mitochondrial membrane potential (ΔΨm) and enhance formation of reactive oxygen species (ROS) as a consequence of ischemia-reperfusion injury. Our data show that DN-MCU hearts had preserved ΔΨm and reduced ROS during ischemia reperfusion but were not protected from myocardial death compared with WT. Taken together, our findings show that chronic myocardial MCU inhibition leads to previously unanticipated compensatory changes that affect cytoplasmic Ca2+ homeostasis, reprogram transcription, increase OCR, reduce performance, and prevent anticipated therapeutic responses to ischemia-reperfusion injury. PMID:26153425
Single channel recording of a mitochondrial calcium uniporter.
Wu, Guangyan; Li, Shunjin; Zong, Guangning; Liu, Xiaofen; Fei, Shuang; Shen, Linda; Guan, Xiangchen; Yang, Xue; Shen, Yuequan
2018-01-29
Mitochondrial calcium uniporter (MCU) is the pore-forming subunit of the entire uniporter complex and plays an important role in mitochondrial calcium uptake. However, the single channel recording of MCU remains controversial. Here, we expressed and purified different MCU proteins and then reconstituted them into planar lipid bilayers for single channel recording. We showed that MCU alone from Pyronema omphalodes (pMCU) is active with prominent single channel Ca 2+ currents. In sharp contrast, MCU alone from Homo sapiens (hMCU) is inactive. The essential MCU regulator (EMRE) activates hMCU, and therefore, the complex (hMCU-hEMRE) shows prominent single channel Ca 2+ currents. These single channel currents are sensitive to the specific MCU inhibitor Ruthenium Red. Our results clearly demonstrate that active MCU can conduct large amounts of calcium into the mitochondria. Copyright © 2018 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Curry, Merril C.; Peters, Amelia A.; Kenny, Paraic A.
Highlights: •Some clinical breast cancers are associated with MCU overexpression. •MCU silencing did not alter cell death initiated with the Bcl-2 inhibitor ABT-263. •MCU silencing potentiated caspase-independent cell death initiated by ionomycin. •MCU silencing promoted ionomycin-mediated cell death without changes in bulk Ca{sup 2+}. -- Abstract: The mitochondrial calcium uniporter (MCU) transports free ionic Ca{sup 2+} into the mitochondrial matrix. We assessed MCU expression in clinical breast cancer samples using microarray analysis and the consequences of MCU silencing in a breast cancer cell line. Our results indicate that estrogen receptor negative and basal-like breast cancers are characterized by elevated levelsmore » of MCU. Silencing of MCU expression in the basal-like MDA-MB-231 breast cancer cell line produced no change in proliferation or cell viability. However, distinct consequences of MCU silencing were seen on cell death pathways. Caspase-dependent cell death initiated by the Bcl-2 inhibitor ABT-263 was not altered by MCU silencing; whereas caspase-independent cell death induced by the calcium ionophore ionomycin was potentiated by MCU silencing. Measurement of cytosolic Ca{sup 2+} levels showed that the promotion of ionomycin-induced cell death by MCU silencing occurs independently of changes in bulk cytosolic Ca{sup 2+} levels. This study demonstrates that MCU overexpression is a feature of some breast cancers and that MCU overexpression may offer a survival advantage against some cell death pathways. MCU inhibitors may be a strategy to increase the effectiveness of therapies that act through the induction of caspase-independent cell death pathways in estrogen receptor negative and basal-like breast cancers.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fondeur, F.; Jones, D.
A trend summary that includes the last two Solvent Hold Tank (SHT) monthly samples is shown; MCU- 17-150-152 (July SHT) and MCU-17-153-155 (August SHT). Since the last SHT sample sent for analysis was the August sample the chemical state of the solvent is best approximated by the chemical analysis of the August SHT sample (MCU-17-153-155). This report mainly focused on the chemical analysis of the August SHT sample. The analysis data from the July SHT sample are presented in the “trend” plots of this report. Analysis of the August SHT sample (MCU-17-153-155) indicated that the modifier (CS-7SB) was 2% belowmore » but the extractant (MaxCalix) concentration was at its nominal recommended level (169,000 mg/L and 46,400 mg/L respectively). The suppressor (TiDG) level has decreased since the last measurement taken while the Modular Caustic-Side Solvent Extraction unit (MCU) was operating in January 2017, but has remained steady in the range of 666 (observed in April) to 715 mg/L (observed in the August 2017 sample) since February 2017, well above the minimum recommended level (479 mg/L), but below the nominal level. The “flat” trends observed in the TiDG, MaxCalix, modifier, and Gamma measurement are consistent with the solvent being idle since January 10, 2017. A strong correlation between density and modifier concentration in the solvent continues to be observed in the SHT samples. This analysis confirms the Isopar™L addition to the solvent in January 2017. This analysis also indicates the solvent did not require further additions. Based on the current monthly sample, the levels of TiDG, Isopar™L, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time if the Modular Caustic-Side Solvent Extraction Unit (MCU) returns to processing radioactive liquid waste. Otherwise, the levels of these components will remain steady. A future Isopar™L trimming addition to the solvent is recommended when MCU resumes processing waste. Two unknown impurities related to the modifier (but not sec-butyl phenol: a modifier degradation product observed before) at the 290 and 110 mg/L levels were observed in the August SHT sample by the Gas - Chromatography-Mass Spectrometry (GC-MS) method. They were observed in a second GC-MS re-run with a new column. Their identification can’t be ascertained at this time. No impurities were observed in the Hydrogen Nuclear Magnetic Resonance (HNMR). Another impurity observed in the samples was mercury. Based on the August SHT sample, up to 23 ± 5 micrograms of mercury per mL of solvent was detected (the average of the Cold Vapor-Atomic Adsorption [CV-AA] and X-Ray Fluorescence [XRF] methods). The higher mercury concentration in the solvent (as determined in the last three-monthly samples) is possibly due to either a higher mercury concentration in Salt Batches 8 and 9 (Tank 49H) . The gamma level (~ 2.0E4 dpm/mL) measured in the August SHT samples was one order of magnitude lower than the gamma levels observed in the December 2016 and January 2017 SHT samples. A similar level was observed in the July SHT sample (MCU-SHT-150-152). The gamma level has remained consistently steady since January 10, 2017 when MCU stopped processing radioactive liquid waste. The laboratory will continue to monitor the quality of the solvent in particularly for any new impurities or degradation of the solvent components.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fondeur, F.; Jones, D.
A trend summary of four Solvent Hold Tank (SHT) monthly samples; MCU-16-122-124 (March 2017), MCU-17-130-132 (April 2017), MCU-17-133-135 (May 2017), and MCU-17-141-149 (June 2017) are reported. Analyses of the June SHT sample (MCU-17-141-149) indicated that the modifier (CS-7SB) and the extractant (MaxCalix) concentrations were slightly below (4% each) their nominal recommended levels (169,000 mg/L and 46,400 mg/L respectively). The suppressor (TiDG) level has decreased since the January 2017 measurement but has remained steady in the range of 666 to 705 mg/L, well above the minimum recommended level (479 mg/L), but below the nominal level. The “flat” trends observed in themore » TiDG, MaxCalix, modifier, and Gamma measurement are consistent with the solvent being idle since January 10, 2017.« less
Camber Angle Inspection for Vehicle Wheel Alignments
Young, Jieh-Shian; Hsu, Hong-Yi; Chuang, Chih-Yuan
2017-01-01
This paper introduces an alternative approach to the camber angle measurement for vehicle wheel alignment. Instead of current commercial approaches that apply computation vision techniques, this study aims at realizing a micro-control-unit (MCU)-based camber inspection system with a 3-axis accelerometer. We analyze the precision of the inspection system for the axis misalignments of the accelerometer. The results show that the axes of the accelerometer can be aligned to the axes of the camber inspection system imperfectly. The calibrations that can amend these axis misalignments between the camber inspection system and the accelerometer are also originally proposed since misalignments will usually happen in fabrications of the inspection systems. During camber angle measurements, the x-axis or z-axis of the camber inspection system and the wheel need not be perfectly aligned in the proposed approach. We accomplished two typical authentic camber angle measurements. The results show that the proposed approach is applicable with a precision of ±0.015∘ and therefore facilitates the camber measurement process without downgrading the precision by employing an appropriate 3-axis accelerometer. In addition, the measured results of camber angles can be transmitted via the medium such as RS232, Bluetooth, and Wi-Fi. PMID:28165365
Hardware system of X-wave generator with simple driving pulses
NASA Astrophysics Data System (ADS)
Li, Xu; Li, Yaqin; Xiao, Feng; Ding, Mingyue; Yuchi, Ming
2013-03-01
The limited diffraction beams such as X-wave have the properties of larger depth of field. Thus, it has the potential to generate ultra-high frame rate ultrasound images. However, in practice, the real-time generation of X-wave ultrasonic field requires complex and high-cost system, especially the precise and specific voltage time distribution part for the excitation of each distinct array element. In order to simplify the hardware realization of X-wave, based on the previous works, X-wave excitation signals were decomposed and expressed as the superposition of a group of simple driving pulses, such as rectangular and triangular waves. The hardware system for the X-wave generator was also designed. The generator consists of a computer for communication with the circuit, universal serial bus (USB) based micro-controller unit (MCU) for data transmission, field programmable gate array (FPGA) based Direct Digital Synthesizer(DDS), 12-bit digital-to-analog (D/A) converter and a two stage amplifier.The hardware simulation results show that the designed system can generate the waveforms at different radius approximating the theoretical X-wave excitations with a maximum error of 0.49% triggered by the quantification of amplitude data.
Development of Ocean-Bottom Seismograph in Taiwan
NASA Astrophysics Data System (ADS)
Chang, H.; Jang, J. P.; Chen, P.; Lin, C. R.; Kuo, B. Y.; Wang, C. C.; Kim, K. H.; Lin, P. P.
2016-12-01
Yardbird-20s, one type of Ocean-Bottom Seismograph (OBS), is fabricated by Taiwan Ocean Research Institute (TORI), the Institute of Earth Science of Academia Sinica and the Institute of Undersea Technology of the National Sun Yat-Sen University in Taiwan. Yardbirds can be deployed up to 5000m deep for up to 15 months. The total weight with anchor in the air is about 170Kg. The rising and sinking rate is about 0.8 m/s. We utilized ultra-low power micro control unit (MCU) and SD card to design a data logger. The sensors are three of 4.5Hz geophones that were extended the lower frequency response to 20 sec. The sensor module also includes the leveling system, which is design by dual-axis DC motor-driven module to level the vertical component to be less than 0.1 degree with respect to the gravity. Yardbirds have been successfully deployed and recovered in several research cruises in Taiwan and Korea. In this study, we'll also display the data quality and power spectral density (PSD) calculations, probability density function (PDF) plots and from the Yardbirds that deployed and recovered in the East Sea near sough-east of Korea.
NASA Astrophysics Data System (ADS)
Paik, Seung-ho; Kim, Beop-Min
2016-03-01
fNIRS is a neuroimaging technique which uses near-infrared light source in the 700-1000 nm range and enables to detect hemodynamic changes (i.e., oxygenated hemoglobin, deoxygenated hemoglobin, blood volume) as a response to various brain processes. In this study, we developed a new, portable, prefrontal fNIRS system which has 12 light sources, 15 detectors and 108 channels with a sampling rate of 2 Hz. The wavelengths of light source are 780nm and 850nm. ATxmega128A1, 8bit of Micro controller unit (MCU) with 200~4095 resolution along with MatLab data acquisition algorithm was utilized. We performed a simple left and right finger movement imagery tasks which produced statistically significant changes of oxyhemoglobin concentrations in the dorsolateral prefrontal cortex (dlPFC) areas. We observed that the accuracy of the imagery tasks can be improved by carrying out neurofeedback training, during which a real-time feedback signal is provided to a participating subject. The effects of the neurofeedback training was later visually verified using the 3D NIRfast imaging. Our portable fNIRS system may be useful in non-constraint environment for various clinical diagnoses.
Intelligent control system based on ARM for lithography tool
NASA Astrophysics Data System (ADS)
Chen, Changlong; Tang, Xiaoping; Hu, Song; Wang, Nan
2014-08-01
The control system of traditional lithography tool is based on PC and MCU. The PC handles the complex algorithm, human-computer interaction, and communicates with MCU via serial port; The MCU controls motors and electromagnetic valves, etc. This mode has shortcomings like big volume, high power consumption, and wasting of PC resource. In this paper, an embedded intelligent control system of lithography tool, based on ARM, is provided. The control system used S5PV210 as processor, completing the functions of PC in traditional lithography tool, and provided a good human-computer interaction by using LCD and capacitive touch screen. Using Android4.0.3 as operating system, the equipment provided a cool and easy UI which made the control more user-friendly, and implemented remote control and debug, pushing video information of product by network programming. As a result, it's convenient for equipment vendor to provide technical support for users. Finally, compared with traditional lithography tool, this design reduced the PC part, making the hardware resources efficiently used and reducing the cost and volume. Introducing embedded OS and the concepts in "The Internet of things" into the design of lithography tool can be a development trend.
The impact of the context and recruitment materials on nondonors' willingness to donate blood.
Masser, Barbara M; France, Christopher R; Himawan, Lina K; Hyde, Melissa K; Smith, Geoff
2016-12-01
Anxiety is a frequently cited barrier to blood donor recruitment. Although the mere presence of donation paraphernalia can heighten anxiety for some individuals, such stimuli are a necessary and unavoidable part of donation. Drawing on France and colleagues' research on tailored donor education and coping materials, the current study assessed whether modifying recruitment materials could improve donor recruitment in a context where anxiety is heightened. A field study comprising a 2 (presence or absence of a mobile blood collection unit [MCU]) × 2 (recruitment brochure: standard, coping) between-subjects design was conducted with 922 nondonors who believed themselves eligible to donate blood. In either the presence or absence of the MCU, participants received a standard or modified recruitment brochure modeled on France and colleagues' education and coping materials. Donation anxiety, attitude, subjective norm, self-efficacy, and intention were assessed, and donation behavior was tracked for 30 days. Participants who were assessed in the presence of the MCU reported heightened anxiety, and female participants reported decreased self-efficacy. The coping brochure improved self-efficacy, heightened the intention to donate in the presence of the MCU, and promoted blood donation behavior relative to the standard brochure. Path analyses supported a model in which, in the presence of the MCU, the coping brochure boosted self-efficacy and led to increased donation intention and behavior. In a context in which donation-related anxiety is heightened, provision of materials that address prospective donor concerns and suggest coping strategies can bolster self-efficacy and promote recruitment. © 2016 AABB.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fondeur, F.; Fink, S.
2012-08-01
During processing of Salt Batches 3 and 4 in the Modular Caustic-Side Solvent Extraction Unit (MCU), the decontamination efficiency for cesium declined from historical values and from expectations based on laboratory testing. This report documents efforts to analyze samples of solvent and process solutions from MCU in an attempt to understand the cause of the reduced performance and to recommend mitigations. CWT Solutions from MCU from the time period of variable decontamination factor (DF) performance which covers from April 2011 to September 2011 (during processing of Salt Batch 4) were examined for impurities using chromatography and spectroscopy. The results indicatemore » that impurities were found to be of two types: aromatic containing impurities most likely from Modifier degradation and aliphatic type impurities most likely from Isopar{reg_sign} L and tri-n-octylamine (TOA) degradation. Caustic washing the Solvent Hold Tank (SHT) solution with 1M NaOH improved its extraction ability as determined from {sup 22}Na uptake tests. Evidence from this work showed that pH variance in the aqueous solutions within the range of 1M nitric acid to 1.91M NaOH that contacted the solvent samples does not influence the analytical determination of the TOA concentration by GC-MS.« less
[Design of modulating intermediate frequency electrotherapy system based on microcontroller unit].
Yu, Xuefei; Liu, Xianfeng; Peng, Daming
2010-12-01
This article is devoted to the design of a system for modulating intermediate frequency electrotherapy waveform output. Prescriptions with different output waveform combinations were produced using microcontroller unit (MCU). The rich output waveforms effectively improve tolerance of human adaptability and achieve a therapeutic effect.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tang, Shihao; Guangzhou No.12 Hospital, Guangzhou; Wang, Xubu
2015-02-27
Metastasis of cancer cells is a complicated multistep process requiring extensive and continuous cytosolic calcium modulation. Mitochondrial Ca{sup 2+} uniporter (MCU), a regulator of mitochondrial Ca{sup 2+} uptake, has been implicated in energy metabolism and various cellular signaling processes. However, whether MCU contributes to cancer cell migration has not been established. Here we examined the expression of MCU mRNA in the Oncomine database and found that MCU is correlated to metastasis and invasive breast cancer. MCU inhibition by ruthenium red (RuR) or MCU silencing by siRNA abolished serum-induced migration in MDA-MB-231 breast cancer cells and reduced serum- or thapsigargin (TG)-inducedmore » store-operated Ca2+ entry (SOCE). Serum-induced migrations in MDA-MB-231 cells were blocked by SOCE inhibitors. Our results demonstrate that MCU plays a critical role in breast cancer cell migration by regulating SOCE. - Highlights: • MCU is correlated to metastasis and invasive breast cancer. • MCU inhibition abolished serum-induced migration in MDA-MB-231 breast cancer cells and reduced serum- or TG-induced SOCE. • Serum-induced migrations in MDA-MB-231 cells were blocked by SOCE inhibitors. • MCU plays a critical role in MDA-MB-231 cell migration by regulating SOCE.« less
NASA Astrophysics Data System (ADS)
Bilalic, Rusmir
A novel application of support vector machines (SVMs), artificial neural networks (ANNs), and Gaussian processes (GPs) for machine learning (GPML) to model microcontroller unit (MCU) upset due to intentional electromagnetic interference (IEMI) is presented. In this approach, an MCU performs a counting operation (0-7) while electromagnetic interference in the form of a radio frequency (RF) pulse is direct-injected into the MCU clock line. Injection times with respect to the clock signal are the clock low, clock rising edge, clock high, and the clock falling edge periods in the clock window during which the MCU is performing initialization and executing the counting procedure. The intent is to cause disruption in the counting operation and model the probability of effect (PoE) using machine learning tools. Five experiments were executed as part of this research, each of which contained a set of 38,300 training points and 38,300 test points, for a total of 383,000 total points with the following experiment variables: injection times with respect to the clock signal, injected RF power, injected RF pulse width, and injected RF frequency. For the 191,500 training points, the average training error was 12.47%, while for the 191,500 test points the average test error was 14.85%, meaning that on average, the machine was able to predict MCU upset with an 85.15% accuracy. Leaving out the results for the worst-performing model (SVM with a linear kernel), the test prediction accuracy for the remaining machines is almost 89%. All three machine learning methods (ANNs, SVMs, and GPML) showed excellent and consistent results in their ability to model and predict the PoE on an MCU due to IEMI. The GP approach performed best during training with a 7.43% average training error, while the ANN technique was most accurate during the test with a 10.80% error.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fondeur, F. F.
During routine maintenance, the coalescers utilized in the Modular Caustic-Side Solvent Extraction Unit (MCU) processing of Salt Batch 6 and a portion of Salt Batch 7 were sampled and submitted to the Savannah River National Laboratory (SRNL) for characterization, for the purpose of identifying solid phase constituents that may be accumulating in these coalescers. Specifically, two samples were received and characterized: A decontaminated salt solution (DSS) coalescer sample and a strip effluent (SE) coalescer sample. Aliquots of the samples were analyzed by XRD, Fourier Transform Infrared (FTIR) Spectroscopy, SEM, and EDS. Other aliquots of the samples were leached in acidmore » solution, and the leachates were analyzed by ICP-AES. In addition, modeling was performed to provide a basis for comparison of the analytical results.« less
Intelligent surgical laser system configuration and software implementation
NASA Astrophysics Data System (ADS)
Hsueh, Chi-Fu T.; Bille, Josef F.
1992-06-01
An intelligent surgical laser system, which can help the ophthalmologist to achieve higher precision and control during their procedures, has been developed by ISL as model CLS 4001. In addition to the laser and laser delivery system, the system is also equipped with a vision system (IPU), robotics motion control (MCU), and a tracking closed loop system (ETS) that tracks the eye in three dimensions (X, Y and Z). The initial patient setup is computer controlled with guidance from the vision system. The tracking system is automatically engaged when the target is in position. A multi-level tracking system is developed by integrating our vision and tracking systems which have been able to maintain our laser beam precisely on target. The capabilities of the automatic eye setup and the tracking in three dimensions provides for improved accuracy and measurement repeatability. The system is operated through the Surgical Control Unit (SCU). The SCU communicates with the IPU and the MCU through both ethernet and RS232. Various scanning pattern (i.e., line, curve, circle, spiral, etc.) can be selected with given parameters. When a warning is activated, a voice message is played that will normally require a panel touch acknowledgement. The reliability of the system is ensured in three levels: (1) hardware, (2) software real time monitoring, and (3) user. The system is currently under clinical validation.
LEACHING OF TITANIUM FROM MONOSODIUM TITANATE AND MODIFIED MST
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor-Pashow, K.; Fondeur, F.; Fink, S.
2012-08-01
Analysis of a fouled coalescer and pre-filters from Actinide Removal Process/Modular Caustic Side Solvent Extraction Unit (ARP/MCU) operations showed evidence of Ti containing solids. Based on these results a series of tests were planned to examine the extent of Ti leaching from monosodium titanate (MST) and modified monosodium titanate (mMST) in various solutions. The solutions tested included a series of salt solutions with varying free hydroxide concentrations, two sodium hydroxide concentrations, 9 wt % and 15 wt %, nitric and oxalic acid solutions. Overall, the amount of Ti leached from the MST and mMST was much greater in the acidmore » solutions compared to the sodium hydroxide or salt solutions, which is consistent with the expected trend. The leaching data also showed that increasing hydroxide concentration, whether pure NaOH solution used for filter cleaning in ARP or the waste salt solution, increased the amount of Ti leached from both the MST and mMST. For the respective nominal contact times with the MST solids - for filter cleaning or the normal filter operation, the dissolved Ti concentrations are comparable suggesting either cause may contribute to the increased Ti fouling on the MCU coalescers. Tests showed that Ti containing solids could be precipitated from solution after the addition of scrub acid and a decrease in temperature similar to expected in MCU operations. FTIR analysis of these solids showed some similarity to the solids observed on the fouled coalescer and pre-filters. Although only a cursory study, this information suggests that the practice of increasing free hydroxide in feed solutions to MCU as a mitigation to aluminosilicate formation may be offset by the impact of formation of Ti solids in the overall process. Additional consideration of this finding from MCU and SWPF operation is warranted.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fondeur, F.
2016-03-01
In February 2015, Savannah River National Laboratory (SRNL) received a Strip Effluent (SE) coalescer (FLT-304) from MCU. That coalescer was first installed at MCU in July 2014 and removed in October 2014. While processing approximately 31,400 gallons of strip solution, the pressure drop steadily increased from 1 psi to beyond the administrative limit of 20 psi. The physical and chemical analysis was conducted on this coalescer to determine the mechanism that led to the plugging of this coalescer. Characterization of this coalescer revealed the adsorption of organic containing amines as well as MCU modifier. The amines are probably from themore » decomposition of the suppressor (TiDG) as well as from bacteria. This adsorption may have changed the surface energetics (characteristics) of the coalescer fibers and therefore, their wetting behavior. A very small amount of inorganic solids were found to have deposited on this coalescer (possibly an artifact of cleaning the coalescer with Boric acid. However, we believe that inorganic precipitation, as has been seen in the past, did not play a role in the high pressure drop rise of this coalescer. With regards to the current practice of reducing the radioactive content of the SE coalescer, it is recommended that future SE coalescer should be flushed with 10 mM boric acid which is currently used at MCU. Plugging of the SE coalescer was most likely due to the formation and accumulation of a water-in-oil emulsion that reduced the overall porosity of the coalescer. There is also evidence that a bimodal oil particle distribution may have entered and deposited in the coalescer and caused the initial increase in pressure drop.« less
Next Generation Solvent Performance in the Modular Caustic Side Solvent Extraction Process - 15495
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, Tara E.; Scherman, Carl; Martin, David
Changes to the Modular Caustic Side Solvent Extraction Unit (MCU) flow-sheet were implemented in the facility. Implementation included changing the scrub and strip chemicals and concentrations, modifying the O/A ratios for the strip, scrub, and extraction contactor banks, and blending the current BoBCalixC6 extractant-based solvent in MCU with clean MaxCalix extractant-based solvent. During the successful demonstration period, the MCU process was subject to rigorous oversight to ensure hydraulic stability and chemical/radionuclide analysis of the key process tanks (caustic wash tank, solvent hold tank, strip effluent hold tank, and decontaminated salt solution hold tank) to evaluate solvent carryover to downstream facilitiesmore » and the effectiveness of cesium removal from the liquid salt waste. Results indicated the extraction of cesium was significantly more effective with an average Decontamination Factor (DF) of 1,129 (range was 107 to 1,824) and that stripping was effective. The contactor hydraulic performance was stable and satisfactory, as indicated by contactor vibration, contactor rotational speed, and flow stability; all of which remained at or near target values. Furthermore, the Solvent Hold Tank (SHT) level and specific gravity was as expected, indicating that solvent integrity and organic hydraulic stability were maintained. The coalescer performances were in the range of processing results under the BOBCalixC6 flow sheet, indicating negligible adverse impact of NGS deployment. After the Demonstration period, MCU began processing via routine operations. Results to date reiterate the enhanced cesium extraction and stripping capability of the Next Generation Solvent (NGS) flow sheet. This paper presents process performance results of the NGS Demonstration and continued operations of MCU utilizing the blended BobCalixC6-MaxCalix solvent under the NGS flowsheet.« less
Nichols, Matthew; Elustondo, Pia A; Warford, Jordan; Thirumaran, Aruloli; Pavlov, Evgeny V; Robertson, George S
2017-08-01
The effects of global mitochondrial calcium (Ca 2+ ) uniporter (MCU) deficiency on hypoxic-ischemic (HI) brain injury, neuronal Ca 2+ handling, bioenergetics and hypoxic preconditioning (HPC) were examined. Forebrain mitochondria isolated from global MCU nulls displayed markedly reduced Ca 2+ uptake and Ca 2+ -induced opening of the membrane permeability transition pore. Despite evidence that these effects should be neuroprotective, global MCU nulls and wild-type (WT) mice suffered comparable HI brain damage. Energetic stress enhanced glycolysis and depressed Complex I activity in global MCU null, relative to WT, cortical neurons. HI reduced forebrain NADH levels more in global MCU nulls than WT mice suggesting that increased glycolytic consumption of NADH suppressed Complex I activity. Compared to WT neurons, pyruvate dehydrogenase (PDH) was hyper-phosphorylated in MCU nulls at several sites that lower the supply of substrates for the tricarboxylic acid cycle. Elevation of cytosolic Ca 2+ with glutamate or ionomycin decreased PDH phosphorylation in MCU null neurons suggesting the use of alternative mitochondrial Ca 2+ transport. Under basal conditions, global MCU nulls showed similar increases of Ca 2+ handling genes in the hippocampus as WT mice subjected to HPC. We propose that long-term adaptations, common to HPC, in global MCU nulls compromise resistance to HI brain injury and disrupt HPC.
Assessment of the impact of TOA partitioning on DWPF off-gas flammability
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daniel, W. E.
2013-06-01
An assessment has been made to evaluate the impact on the DWPF melter off-gas flammability of increasing the amount of TOA in the current solvent used in the Modular Caustic-Side Solvent Extraction Process Unit (MCU) process. The results of this study showed that the concentrations of nonvolatile carbon of the current solvent limit (150 ppm) in the Slurry Mix Evaporator (SME) product would be about 7% higher and the nonvolatile hydrogen would be 2% higher than the actual current solvent (126 ppm) with an addition of up to 3 ppm of TOA when the concentration of Isopar L in themore » effluent transfer is controlled below 87 ppm and the volume of MCU effluent transfer to DWPF is limited to 15,000 gallons per Sludge Receipt and Adjustment Tank (SRAT)/SME cycle. Therefore, the DWPF melter off-gas flammability assessment is conservative for up to an additional 3 ppm of TOA in the effluent based on these assumptions. This report documents the calculations performed to reach this conclusion.« less
Design of vehicle intelligent anti-collision warning system
NASA Astrophysics Data System (ADS)
Xu, Yangyang; Wang, Ying
2018-05-01
This paper mainly designs a low cost, high-accuracy, micro-miniaturization, and digital display and acousto-optic alarm features of the vehicle intelligent anti-collision warning system that based on MCU AT89C51. The vehicle intelligent anti-collision warning system includes forward anti-collision warning system, auto parking systems and reversing anti-collision radar system. It mainly develops on the basis of ultrasonic distance measurement, its performance is reliable, thus the driving safety is greatly improved and the parking security and efficiency enhance enormously.
SOLIDS PRECIPITATION EVENT IN MCU CAUSAL ANALYSIS AND RECOMMENDATIONS FROM SOLIDS RECOVERY TEAM
DOE Office of Scientific and Technical Information (OSTI.GOV)
Garrison, A.; Aponte, C.
A process upset occurred in the Modular Caustic-Side Solvent Extraction Unit (MCU) facility on April 6th, 2014. During recovery efforts, a significant amount of solids were found in the Salt Solution Feed Tank (SSFT), Salt Solution Receipt Tanks (SSRTs), two extraction contactors, and scrub contactors. The solids were identified by Savannah River National Laboratory (SRNL) as primarily sodium oxalate and sodium alumina silicate (NAS) with the presence of some aluminum hydroxide. NAS solids have been present in the SSFT since simulant runs during cold chemical startup of MCU in 2007, and have not hindered operations since that time. During themore » process upset in April 2014, the oxalate solids partially blocked the aqueous outlet of the extraction contactors, causing salt solution to exit through the contactor organic outlet to the scrub contactors with the organic phase. This salt solution overwhelmed the scrub contactors and passed with the organic phase to the strip section of MCU. The partially reversed flow of salt solution resulted in a Strip Effluent (SE) stream that was high in Isopar™ L, pH and sodium. The primary cause of the excessive solids accumulation in the SSRTs and SSFT at MCU is attributed to an increase in the frequency of oxalic acid cleaning of the 512-S primary filter. Agitation in the SSRTs at MCU in response to cold weather likely provided the primary mechanism to transfer the solids to the contactors. Sources of the sodium oxalate solids are attributed to the oxalic acid cleaning solution used to clean the primary filter at the Actinide Removal Process (ARP) filtration at 512-S, as well as precipitation from the salt batch feed, which is at or near oxalate saturation. The Solids Recovery Team was formed to determine the cause of the solids formation and develop recommendations to prevent or mitigate this event in the future. A total of 53 recommendations were generated. These recommendations were organized into 4 focus areas: • Improve understanding of oxalate equilibrium and kinetics in salt solutions • Reduction/elimination of oxalic acid cleaning in 512-S • Flowsheet optimization • Improving diagnostic capability The recommendations implemented prior to resumption of MCU operations provide a risk mitigation or detection function through additional sampling and observation. The longer term recommendations provide a framework to increase the basic process knowledge of both oxalate chemistry and filtration behavior and then facilitate decisions that improve the salt flowsheet as a system.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, T.; Fondeur, F.; Fink, S.
Solvent Hold Tank (SHT) samples are sent to Savannah River National Laboratory (SRNL) to examine solvent composition changes over time. On December 5, 2011, Operations personnel delivered six samples from the SHT (MCU-11-1452 through -1457) for analysis. These samples are intended to verify that the solvent is within the specified composition range. The results from the analyses are presented in this document. Samples were received in p-nut vials containing {approx}10 mL each. Once taken into the Shielded Cells, the samples were combined. Samples were removed for analysis by density, semi-volatile organic analysis (SVOA), high performance liquid chromatography (HPLC), and Fourier-Transformmore » Infra-Red spectroscopy (FTIR). Details for the work are contained in a controlled laboratory notebook. Each of the six p-nut vials contained a single phase, with no apparent solids contamination or cloudiness. Table 1 contains the results of the analyses for the combined samples. A duplicate density measurement of the organic phase gave a result of 0.844 g/mL (1.2% residual standard deviation - RSD). Using the density as a starting point, we know that the Isopar{reg_sign} L should be slightly higher than nominal and the other components should be slightly lower than nominal. The results as a whole are internally consistent. All measurements indicate Isopar{reg_sign} L higher than nominal, and Modifier lower than nominal. The extractant result is higher than expected - given the other results, the extractant concentration should be under nominal values. Using the measured density as well as the Isopar{reg_sign} L and Modifier concentrations from the FTIR results, we calculate an extractant concentration of 6888 mg/L. This value is outside the analytical uncertainty of the reported HPLC value. Given the other results, this most likely indicates that the HPLC extractant result was biased high. When compared to the MCU density target of 0.845 g/mL, there is no need to add an Isopar{reg_sign} L trim. However, it is advisable to add sufficient trioctylamine (TOA) to return the solvent composition to within specifications as that component has declined to about 64% the concentration since the last analysis. The TOA measurement was performed twice, so the result is not an analytical aberration. TOA has not been added to the system since the previous quarterly sample in October 2011. As with the previous solvent sample results, these analyses indicate that the solvent does not require Isopar{reg_sign} L trimming at this time. However, addition of TOA is warranted. These findings indicate that the new protocols for solvent monitoring and control are yielding favorable results. Nevertheless, the deviation in the TOA concentration since the last analysis indicates continued periodic (i.e., quarterly) monitoring is recommended.« less
Jhun, Bong Sook; Xu, Shangcheng; Hurst, Stephen; Raffaello, Anna; Liu, Xiaoyun; Yi, Bing; Zhang, Huiliang; Gross, Polina; Mishra, Jyotsna; Ainbinder, Alina; Kettlewell, Sarah; Smith, Godfrey L.; Dirksen, Robert T.; Wang, Wang; Rizzuto, Rosario
2014-01-01
Abstract Aims: Mitochondrial Ca2+ homeostasis is crucial for balancing cell survival and death. The recent discovery of the molecular identity of the mitochondrial Ca2+ uniporter pore (MCU) opens new possibilities for applying genetic approaches to study mitochondrial Ca2+ regulation in various cell types, including cardiac myocytes. Basal tyrosine phosphorylation of MCU was reported from mass spectroscopy of human and mouse tissues, but the signaling pathways that regulate mitochondrial Ca2+ entry through posttranslational modifications of MCU are completely unknown. Therefore, we investigated α1-adrenergic-mediated signal transduction of MCU posttranslational modification and function in cardiac cells. Results: α1-adrenoceptor (α1-AR) signaling translocated activated proline-rich tyrosine kinase 2 (Pyk2) from the cytosol to mitochondrial matrix and accelerates mitochondrial Ca2+ uptake via Pyk2-dependent MCU phosphorylation and tetrametric MCU channel pore formation. Moreover, we found that α1-AR stimulation increases reactive oxygen species production at mitochondria, mitochondrial permeability transition pore activity, and initiates apoptotic signaling via Pyk2-dependent MCU activation and mitochondrial Ca2+ overload. Innovation: Our data indicate that inhibition of α1-AR-Pyk2-MCU signaling represents a potential novel therapeutic target to limit or prevent mitochondrial Ca2+ overload, oxidative stress, mitochondrial injury, and myocardial death during pathophysiological conditions, where chronic adrenergic stimulation is present. Conclusion: The α1-AR-Pyk2-dependent tyrosine phosphorylation of the MCU regulates mitochondrial Ca2+ entry and apoptosis in cardiac cells. Antioxid. Redox Signal. 21, 863–879. PMID:24800979
Solvent Hold Tank Sample Results for MCU-15-129-130-131: January 2015 Monthly Sample
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fondeur, F. F.; Taylor-Pashow, K. M. L.
2015-02-19
SRNL received one set of SHT samples (MCU-15-129, MCU-15-130, and MCU-15-131), pulled on 01/25/2015 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-15-129-130-131 indicated low concentrations of the suppressor (TiDG), of the extractant (MaxCalix), and of the modifier (CS-7SB) in the solvent relative to their nominal values. This analysis confirms a downward trend of these components. No impurities were found in this solvent. The laboratory will continue to monitor the quality of the solvent in particular for any new impurity or degradation of the solvent components.
ANALYSIS OF OUT OF DATE MCU MODIFIER LOCATED IN SRNL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crawford, C.
2014-10-22
SRNL recently completed density measurements and chemical analyses on modifier samples stored in drums within SRNL. The modifier samples date back to 2008 and are in various quantities up to 40 gallons. Vendor information on the original samples indicates a shelf life of 5 years. There is interest in determining if samples that have been stored for more than the 5 year shelf life are still acceptable for use. The Modular Caustic Side Solvent Extraction Unit (MCU) Solvent component Cs-7SB [(2,2,3,3- tetraflouropropoxy)-3-(4-sec-butylphenoxy)-2-propanol, CAS #308362-88-1] is used as a diluent modifier to increase extractant solubility and provide physical characteristics necessary formore » diluent trimming.« less
Pearson, Isabelle; Reichert, Alison; De Serres, Sophie J; Dumas, Jean-Pierre; Côté, Julie N
2009-03-01
Controlled laboratory study using a cross-sectional, repeated-measures design. To quantify maximal voluntary isometric neck forces in healthy subjects and individuals with whiplash-associated disorder (WAD), using an objective measurement system to evaluate the test-retest properties of these strength measurements and to assess the links between neck strength, pain, kinesiophobia, and catastrophizing in patients with WAD. The prognosis of WAD is difficult to predict due to a lack of objective measurement methods and to our limited understanding of the role of psychological factors in the development of chronic WAD symptoms. Fourteen subjects with chronic WAD grade I or II and an age-matched, healthy group (n = 28) participated in this study. Cervical strength was measured with the Multi-Cervical Unit (MCU) in 6 directions, and pain was measured with a visual analog scale. Individuals in the WAD group completed the Neck Disability Index (NDI), the Tampa Scale for Kinesiophobia (TSK), and the Pain Catastrophizing Scale (PCS). Significant deficits in strength were observed for the individuals in the WAD group compared to the healthy group, particularly in extension, retraction, and left lateral flexion (P<.05). The MCU demonstrated good intratester reliability for the healthy group (ICC = 0.80-0.92) and the WAD group (ICC = 0.85-0.98), and small standard errors of measurement for both groups. No significant association was found between neck strength and NDI, TSK, and PCS. The MCU demonstrated good test-retest properties for healthy subjects and individuals with WAD. Cervical strength was lower in individuals with WAD; however, the strength deficits were not clearly linked with psychological factors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fondeur, F.; Taylor-Pashow, K.
Savannah River National Laboratory (SRNL) received two sets of Solvent Hold Tank (SHT) samples (MCU-15-389 and MCU-15-390 pulled on February 23, 2015 and MCU-15-439, MCU-15-440, and MCU-15-441 pulled on February 28, 2015) for analysis. The samples in each set were combined and analyzed for composition. Analysis of the composite samples MCU-15-389-390 and MCU-15-439-440- 441 indicated a low concentration (~ 92 to 93 % of nominal) of the suppressor (TiDG) and slightly below nominal concentrations of the extractant (MaxCalix), but nominal levels of the modifier (CS-7SB) and of the Isopar™ L. This analysis confirms the addition of TiDG, MaxCalix, and modifiermore » to the solvent on February 22, 2015. Despite that the values are below the target component levels, the current levels of TiDG and MaxCalix are sufficient for continuing operation without adding a trim at this time. No impurities above the 1000 ppm level were found in this solvent. However, the p-nut vials that delivered the samples contained small (1 mm) droplets of oxidized modifier and amides. The laboratory will continue to monitor the quality of the solvent in particular for any new impurity or degradation of the solvent components.« less
Oropeza-Almazán, Yuriana; Vázquez-Garza, Eduardo; Chapoy-Villanueva, Héctor; Torre-Amione, Guillermo; García-Rivas, Gerardo
2017-01-01
Intracellular Ca 2+ mishandling is an underlying mechanism in hypoxia/reoxygenation (H/R) injury that results in mitochondrial dysfunction and cardiomyocytes death. These events are mediated by mitochondrial Ca 2+ ( m Ca 2+ ) overload that is facilitated by the mitochondrial calcium uniporter (MCU) channel. Along this line, we evaluated the effect of siRNA-targeting MCU in cardiomyocytes subjected to H/R injury. First, cardiomyocytes treated with siRNA demonstrated a reduction of MCU expression by 67%, which resulted in significant decrease in mitochondrial Ca 2+ transport. siRNA treated cardiomyocytes showed decreased mitochondrial permeability pore opening and oxidative stress trigger by Ca 2+ overload. Furthermore, after H/R injury MCU silencing decreased necrosis and apoptosis levels by 30% and 50%, respectively, and resulted in reduction in caspases 3/7, 9, and 8 activity. Our findings are consistent with previous conclusions that demonstrate that MCU activity is partly responsible for cellular injury induced by H/R and support the concept of utilizing siRNA-targeting MCU as a potential therapeutic strategy.
Slow Controls Using the Axiom M5235BCC
NASA Astrophysics Data System (ADS)
Hague, Tyler
2008-10-01
The Forward Vertex Detector group at PHENIX plans to adopt the Axiom M5235 Business Card Controller for use as slow controls. It is also being evaluated for slow controls on FermiLab e906. This controller features the Freescale MCF5235 microprocessor. It also has three parallel buses, these being the MCU port, BUS port, and enhanced Time Processing Unit (eTPU) port. The BUS port uses a chip select module with three external chip selects to communicate with peripherals. This will be used to communicate with and configure Field Programmable Gate Arrays (FPGAs). The controller also has an Ethernet port which can use several different protocols such as TCP and UDP. This will be used to transfer files with computers on a network. The M5235 Business Card Controller will be placed in a VME crate along with VME card and a Spartan-3 FPGA.
Identification And Characterization Of The Solids Found In Extraction Contactor SEP-401 In June 2012
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fondeur, F. F.; Fink, S. D.
2012-12-10
The Modular Caustic-Side Solvent Extraction Unit (MCU) recently conducted an outage that included maintenance on the centrifugal contactors. Operations personnel observed solids or deposits in two contactors and attempted to collect samples for analyses by Savannah River National Laboratory (SRNL). The residues found in Extraction Contactor SEP-401 are a mixture of amorphous silica, aluminosilicate, titanium, and debris from low alloy steel. The solids contain low concentrations of plutonium and strontium. These isotopes are associated with the titanium that came from the monosodium titanate (MST) added in the Actinide Removal Process (ARP) most likely as leached Ti from the MST thatmore » precipitated subsequently in MCU. An attempt was also made to obtain samples from the contents of Wash Contactor SEP-702. However, sampling provide ineffective.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bannochie, C. J.
2013-04-29
Implementation of the Next Generation Solvent (NGS) in the Modular Caustic-Side Solvent Extraction Unit (MCU) will now proceed with a new suppressor compound, 1,2,3-tris(3,7-dimethyloctyl)guanidine (TiDG), replacing the originally planned suppressor for NGS, 1,3-dicyclohexyl-2-(11-methyldodecyl) guanidine (DCiTG). The Savannah River National Laboratory (SRNL) was tasked with evaluating the potential impact to F/H Laboratory analyses supporting the Defense Waste Processing Facility (DWPF) Waste Acceptance Criteria (WAC) used to qualify transfers of MCU Strip Effluent (SE) into the facility and the Saltstone WAC used to qualify transfers of Tank 50 containing Decontaminated Salt Solution (DSS) from MCU into Saltstone. This assigned scope is coveredmore » by a Task Technical and Quality Assurance Plan (TTQAP). Previous impact evaluations were conducted when the DCiTG suppressor was planned for NGS and concluded that there was no impact to either the determination of MCU SE pH nor the analysis of Isopar® L carryover in the MCU SE and DSS streams. SRNL reported on this series of cross-check studies between the SRNL and F/H Laboratories. The change in suppressor from DCiTG to TiDG in the NGS should not impact the measurement of Isopar® L or pH in SE or DSS necessary to satisfy DWPF and Saltstone WAC (Tank 50) criteria, respectively. A statistical study of the low bias observed in Isopar® L measurements in both SRNL and F/H Laboratories may be necessary now that the final NGS composition is fixed in order to quantify the low bias so that a proper correction can be applied to measurements critical to the DWPF and Saltstone WACs. Depending upon the final DWPF WAC requirement put in place for SE pH, it could become necessary to implement an alternative ICP-AES measurement of boron. The current blended solvent system testing in SRNL should address any impacts to Isopar® L carryover into either the DSS or the SE. It is recommended that SRNL monitor the current blended solvent work underway with simulants in SRNL as well as any DWPF CPC testing done with the new SE stream to ascertain whether any need develops that could result in modification of any currently planned F/H Laboratory testing protocols.« less
Lee, Chi-Ying; Gong, Ping; Harbers, Gregory M.; Grainger, David W.; Castner, David G.; Gamble, Lara J.
2006-01-01
Self-assembly of thiol-terminated single-stranded DNA (HS-ssDNA) on gold has served as an important model system for DNA immobilization at surfaces. Here, we report a detailed study of the surface composition and structure of mixed self-assembled DNA monolayers containing a short alkylthiol surface diluent [11-mercapto-1-undecanol (MCU)] on gold supports. These mixed DNA monolayers were studied with X-ray photoelectron spectroscopy (XPS), near-edge X-ray absorption fine structure spectroscopy (NEXAFS), and fluorescence intensity measurements. XPS results on sequentially adsorbed DNA/MCU monolayers on gold indicated that adsorbed MCU molecules first incorporate into the HS-ssDNA monolayer and, upon longer MCU exposures, displace adsorbed HS-ssDNA molecules from the surface. Thus, HS-ssDNA surface coverage steadily decreased with MCU exposure time. Polarization-dependent NEXAFS and fluorescence results both show changes in signals consistent with changes in DNA orientation after only 30 min of MCU exposure. NEXAFS polarization dependence (followed by monitoring the N 1s → π* transition) of the mixed DNA monolayers indicated that the DNA nucleotide base ring structures are oriented more parallel to the gold surface compared to DNA bases in pure HS-ssDNA monolayers. This indicates that HS-ssDNA oligomers reorient toward a more-upright position upon MCU incorporation. Fluorescence intensity results using end-labeled DNA probes on gold show little observable fluorescence on pure HS-ssDNA monolayers, likely due to substrate quenching effects between the fluorophore and the gold. MCU diluent incorporation into HS-ssDNA monolayers initially increases DNA fluorescence signal by densifying the chemisorbed monolayer, prompting an upright orientation of the DNA, and moving the terminal fluorophore away from the substrate. Immobilized DNA probe density and DNA target hybridization in these mixed DNA monolayers, as well as effects of MCU diluent on DNA hybridization in complex milieu (i.e., serum) were characterized by surface plasmon resonance (SPR) and 32P-radiometric assays and reported in a related study PMID:16689533
Lai, Jinxing; Qiu, Junling; Chen, Jianxun; Wang, Yaqiong; Fan, Haobo
2014-01-01
Because of the particularity of the environment in the tunnel, the rational tunnel illumination system should be developed, so as to optimize the tunnel environment. Considering the high cost of traditional tunnel illumination system with high-pressure sodium (HPS) lamps as well as the effect of a single light source on tunnel entrance, the energy-saving illumination system with HPS lamps and LEDs combined illumination in road tunnel, which could make full use of these two kinds of lamps, was proposed. The wireless intelligent control system based on HPS lamps and LEDs combined illumination and microcontrol unit (MCU) Si1000 wireless communication technology was designed. And the remote monitoring, wireless communication, and PWM dimming module of this system were designed emphatically. Intensity detector and vehicle flow detector can be configured in wireless intelligent control system, which gather the information to the master control unit, and then the information is sent to the monitoring center through the Ethernet. The control strategies are got by the monitoring center according to the calculated results, and the control unit wirelessly sends parameters to lamps, which adjust the luminance of each segment of the tunnel and realize the wireless intelligent control of combined illumination in road tunnel. PMID:25587266
Mitochondrial Calcium Transport in Trypanosomes
Docampo, Roberto; Vercesi, Anibal E.; Huang, Guozhong
2014-01-01
The biochemical peculiarities of trypanosomes were fundamental for the recent molecular identification of the long-sought channel involved in mitochondrial Ca2+ uptake, the mitochondrial Ca2+ uniporter or MCU. This discovery led to the finding of numerous regulators of the channel, which form a high molecular weight complex with MCU. Some of these regulators have been bioinformatically identified in trypanosomes, which are the first eukaryotic organisms described for which MCU is essential. In trypanosomes MCU is important for buffering cytosolic Ca2+ changes and for activation of the bioenergetics of the cells. Future work on this pathway in trypanosomes promises further insight into the biology of these fascinating eukaryotes, as well as the potential for novel target discovery. PMID:25218432
A UAV-based gas sensing system for detecting fugitive methane emissions
NASA Astrophysics Data System (ADS)
Hugenholtz, C.; Barchyn, T.; Myshak, S.; Bauer, J.
2016-12-01
Methane is one of the most prevalent greenhouse gases emitted by human activities and is a major component of government-led initiatives to reduce GHG emissions in Canada, the USA, and elsewhere. In light of growing demand for measurements and verification of atmospheric methane concentration across the oil and gas supply chain, an autonomous airborne gas sensing system was developed that combines a small UAV and a lightweight gas monitor. This paper outlines the technology, analytics, and presents data from a case study to demonstrate the proof of concept. The UAV is a fixed-wing (2.2 m wingspan), battery-operated platform, with a flight endurance of 80-120 minutes. The gas sensor onboard the UAV is a tunable diode laser absorption spectrometer that uses an integrated transmitter/receiver unit and a remote, passive retro-reflector. The transmitter is attached to one of the winglets, while the other is coated with reflective material. The total weight of the UAV and gas sensor is 4.3 kg. During flight, the system operates autonomously, acquiring averages of raw measurements at 1 Hz, with a recorded resolution of 0.0455 ppm. The onboard measurement and control unit (MCU) for the gas sensor is integrated with the UAV autopilot in order to provide time-stamped and geotagged concentration measurements, and to provide real-time flight adjustments when concentration exceeds a pre-determined threshold. The data are retrieved from the MCU when the mission is complete. In order to demonstrate the proof of concept, we present results from a case study and outline opportunities for translating the measurements into decision making.
Systematic Identification of MCU Modulators by Orthogonal Interspecies Chemical Screening.
Arduino, Daniela M; Wettmarshausen, Jennifer; Vais, Horia; Navas-Navarro, Paloma; Cheng, Yiming; Leimpek, Anja; Ma, Zhongming; Delrio-Lorenzo, Alba; Giordano, Andrea; Garcia-Perez, Cecilia; Médard, Guillaume; Kuster, Bernhard; García-Sancho, Javier; Mokranjac, Dejana; Foskett, J Kevin; Alonso, M Teresa; Perocchi, Fabiana
2017-08-17
The mitochondrial calcium uniporter complex is essential for calcium (Ca 2+ ) uptake into mitochondria of all mammalian tissues, where it regulates bioenergetics, cell death, and Ca 2+ signal transduction. Despite its involvement in several human diseases, we currently lack pharmacological agents for targeting uniporter activity. Here we introduce a high-throughput assay that selects for human MCU-specific small-molecule modulators in primary drug screens. Using isolated yeast mitochondria, reconstituted with human MCU, its essential regulator EMRE, and aequorin, and exploiting a D-lactate- and mannitol/sucrose-based bioenergetic shunt that greatly minimizes false-positive hits, we identify mitoxantrone out of more than 600 clinically approved drugs as a direct selective inhibitor of human MCU. We validate mitoxantrone in orthogonal mammalian cell-based assays, demonstrating that our screening approach is an effective and robust tool for MCU-specific drug discovery and, more generally, for the identification of compounds that target mitochondrial functions. Copyright © 2017 Elsevier Inc. All rights reserved.
Maps showing distribution of the Middle Cretaceous unconformity in the eastern Gulf of Mexico
Massingill, L.M.; Wells, R.H.
1987-01-01
This report emphasizes the salt diapirs, pillows, and ridges in the northeastern Gulf of Mexico because of the profound effect these geologic structures have on the MCU. Salt locations are shown on the isopach of post-MCU sediments (fig. 1). A second map shows pre-middle Cretaceous outcrops terminated by the MCU along the Florida Escarpment, the southeastern Gulf, and the Campeche Escarpment (fig. 2).
Kwon, Seok-Kyu; Sando, Richard; Lewis, Tommy L; Hirabayashi, Yusuke; Maximov, Anton; Polleux, Franck
2016-07-01
Individual synapses vary significantly in their neurotransmitter release properties, which underlie complex information processing in neural circuits. Presynaptic Ca2+ homeostasis plays a critical role in specifying neurotransmitter release properties, but the mechanisms regulating synapse-specific Ca2+ homeostasis in the mammalian brain are still poorly understood. Using electrophysiology and genetically encoded Ca2+ sensors targeted to the mitochondrial matrix or to presynaptic boutons of cortical pyramidal neurons, we demonstrate that the presence or absence of mitochondria at presynaptic boutons dictates neurotransmitter release properties through Mitochondrial Calcium Uniporter (MCU)-dependent Ca2+ clearance. We demonstrate that the serine/threonine kinase LKB1 regulates MCU expression, mitochondria-dependent Ca2+ clearance, and thereby, presynaptic release properties. Re-establishment of MCU-dependent mitochondrial Ca2+ uptake at glutamatergic synapses rescues the altered neurotransmitter release properties characterizing LKB1-null cortical axons. Our results provide novel insights into the cellular and molecular mechanisms whereby mitochondria control neurotransmitter release properties in a bouton-specific way through presynaptic Ca2+ clearance.
NASA Astrophysics Data System (ADS)
Tapani Nikkanen, Timo; Hieta, Maria; Schmidt, Walter; Genzer, Maria; Haukka, Harri; Harri, Ari-Matti
2016-04-01
The Finnish Meteorological Institute (FMI) has delivered a pressure and a humidity instrument for the ESA ExoMars 2016 Schiaparelli lander mission. Schiaparelli is scheduled to launch towards Mars with the Trace Gas Orbiter on 14th of March 2016. The DREAMS-P (pressure) and DREAMS-H (Humidity) instruments are operated utilizing a novel FMI instrument controller design based on a commercial automotive microcontroller (MCU). A custom qualification program was implemented to qualify the MCU for the relevant launch, cruise and surface operations environment of a Mars lander. Resilience to ionizing radiation is one of the most critical requirements for a digital component operated in space or at planetary bodies. Thus, the expected Total Ionizing Dose accumulated by the MCU was determined and a sample of these components was exposed to a Co-60 gamma radiation source. Part of the samples was powered during the radiation exposure to include the effect of electrical biasing. All of the samples were verified to withstand the expected total ionizing dose with margin. The irradiated test samples were then radiated until failure to determine their ultimate TID.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fondeur, F.; Taylor-Pashow, K.
2014-08-05
SRNL received two sets of SHT samples (MCU-14-259/260/261 in April 2014 and MCU-14- 315/316/317 in May 2014) for analysis. The samples were analyzed for composition. Both samples have similar chemical composition. As with the previous solvent sample results, these analyses indicate that the solvent does not require Isopar® L trimming at this time. Since an addition of TiDG and MaxCalix to the SHT was added in early July 2014, the solvent does not require TiDG addition at this time. The current TiDG level (1.5 mM) is above the minimum recommended operating level of 1 mM.
Laboratory-scale integrated ARP filter test
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poirier, M.; Burket, P.
2016-03-01
The Savannah River Site (SRS) is currently treating radioactive liquid waste with the Actinide Removal Process (ARP) and the Modular Caustic Side Solvent Extraction Unit (MCU). Recently, the low filter flux through the ARP of approximately 5 gallons per minute has limited the rate at which radioactive liquid waste can be treated. Salt Batch 6 had a lower processing rate and required frequent filter cleaning. There is a desire to understand the causes of the low filter flux and to increase ARP/MCU throughput. This task attempted to simulate the entire ARP process, including multiple batches (5), washing, chemical cleaning, andmore » blending the feed with heels and recycle streams. The objective of the tests was to determine whether one of these processes is causing excessive fouling of the crossflow or secondary filter. The authors conducted the tests with feed solutions containing 6.6 M sodium Salt Batch 6 simulant supernate with no MST.« less
Gong, Ping; Lee, Chi-Ying; Gamble, Lara J; Castner, David G; Grainger, David W
2006-05-15
Nucleic acid assay from a complex biological milieu is attractive but currently difficult and far from routine. In this study, DNA hybridization from serum dilutions into mixed DNA/mercaptoundecanol (MCU) adlayers on gold was monitored by surface plasmon resonance (SPR). Immobilized DNA probe and hybridized target densities on these surfaces were quantified using 32P-radiometric assays as a function of MCU diluent exposure. SPR surface capture results correlated with radiometric analysis for hybridization performance, demonstrating a maximum DNA hybridization on DNA/MCU mixed adlayers. The maximum target surface capture produced by MCU addition to the DNA probe layer correlates with structural and conformational data on identical mixed DNA/MCU adlayers on gold derived from XPS, NEXAFS, and fluorescence intensity measurements reported in a related study (Lee, C.-Y.; Gong, P.; Harbers, G. M.; Grainger, D. W.; Castner, D. G.; Gamble, L. J. Anal. Chem. 2006, 78, 3316-3325.). MCU addition into the DNA adlayer on gold also improved surface resistance to both nonspecific DNA and serum protein adsorption. Target DNA hybridization from serum dilutions was monitored with SPR on the optimally mixed DNA/MCU adlayers. Both hybridization kinetics and efficiency were strongly affected by nonspecific protein adsorption from a complex milieu even at a minimal serum concentration (e.g., 1%). No target hybridization was detected in SPR assays from serum concentrations above 30%, indicating nonspecific protein adsorption interference of DNA capture and hybridization from complex milieu. Removal of nonsignal proteins from nucleic acid targets prior to assay represents a significant issue for direct sample-to-assay nucleic acid diagnostics from food, blood, tissue, PCR mixtures, and many other biologically complex sample formats.
The m-AAA Protease Associated with Neurodegeneration Limits MCU Activity in Mitochondria.
König, Tim; Tröder, Simon E; Bakka, Kavya; Korwitz, Anne; Richter-Dennerlein, Ricarda; Lampe, Philipp A; Patron, Maria; Mühlmeister, Mareike; Guerrero-Castillo, Sergio; Brandt, Ulrich; Decker, Thorsten; Lauria, Ines; Paggio, Angela; Rizzuto, Rosario; Rugarli, Elena I; De Stefani, Diego; Langer, Thomas
2016-10-06
Mutations in subunits of mitochondrial m-AAA proteases in the inner membrane cause neurodegeneration in spinocerebellar ataxia (SCA28) and hereditary spastic paraplegia (HSP7). m-AAA proteases preserve mitochondrial proteostasis, mitochondrial morphology, and efficient OXPHOS activity, but the cause for neuronal loss in disease is unknown. We have determined the neuronal interactome of m-AAA proteases in mice and identified a complex with C2ORF47 (termed MAIP1), which counteracts cell death by regulating the assembly of the mitochondrial Ca 2+ uniporter MCU. While MAIP1 assists biogenesis of the MCU subunit EMRE, the m-AAA protease degrades non-assembled EMRE and ensures efficient assembly of gatekeeper subunits with MCU. Loss of the m-AAA protease results in accumulation of constitutively active MCU-EMRE channels lacking gatekeeper subunits in neuronal mitochondria and facilitates mitochondrial Ca 2+ overload, mitochondrial permeability transition pore opening, and neuronal death. Together, our results explain neuronal loss in m-AAA protease deficiency by deregulated mitochondrial Ca 2+ homeostasis. Copyright © 2016 Elsevier Inc. All rights reserved.
Mercury Phase II Study - Mercury Behavior across the High-Level Waste Evaporator System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bannochie, C. J.; Crawford, C. L.; Jackson, D. G.
2016-06-17
The Mercury Program team’s effort continues to develop more fundamental information concerning mercury behavior across the liquid waste facilities and unit operations. Previously, the team examined the mercury chemistry across salt processing, including the Actinide Removal Process/Modular Caustic Side Solvent Extraction Unit (ARP/MCU), and the Defense Waste Processing Facility (DWPF) flowsheets. This report documents the data and understanding of mercury across the high level waste 2H and 3H evaporator systems.
Lazar, Amanda; Demiris, George; Thompson, Hilaire J
2016-12-01
Stimulating recreational and leisure activities (RLAs) are essential to physical and mental well-being; however, people living in memory care units (MCUs) may lack access to them. Technology has the potential to facilitate and enrich activity engagement in this context. In this 6-month study, we evaluated a commercially available system designed to encourage the engagement of people with dementia in activities and social interactions, using a mixed-methods approach in a MCU. Quantitative measures included those to evaluate cognition, depression, quality of life, and resource utilization. We qualitatively evaluated the system using semi-structured interviews with family members and staff. Five residents with dementia, four family members, and seven staff were included in the 6-month study. Staff and family members reported benefits for residents such as enjoyment, interactions and connections with others, and mental stimulation. Findings also highlight challenges such as technical and ethical concerns. Factors that influence system use and integration are also discussed. It was feasible to introduce a system designed for recreation and engagement in a MCU, and staff, family members, and residents experienced benefits. However, barriers existed in the introduction and use of the system.
Lazar, Amanda; Demiris, George; Thompson, Hilaire J.
2016-01-01
Introduction Stimulating recreational and leisure activities (RLAs) are essential to physical and mental well-being; however, people living in memory care units (MCUs) may lack access to them. Technology has the potential to facilitate and enrich activity engagement in this context. Objectives In this 6-month study, we evaluated a commercially available system designed to encourage the engagement of people with dementia in activities and social interactions, using a mixed-methods approach in a MCU. Methods Quantitative measures included those to evaluate cognition, depression, quality of life, and resource utilization. We qualitatively evaluated the system using semi-structured interviews with family members and staff. Five residents with dementia, four family members, and seven staff were included in the 6-month study. Results Staff and family members reported benefits for residents such as enjoyment, interactions and connections with others, and mental stimulation. Findings also highlight challenges such as technical and ethical concerns. Factors that influence system use and integration are also discussed. Conclusion It was feasible to introduce a system designed for recreation and engagement in a MCU, and staff, family members, and residents experienced benefits. However, barriers existed in the introduction and use of the system. PMID:26819070
NASA Astrophysics Data System (ADS)
Nogami, Hirofumi; Kobayashi, Takeshi; Okada, Hironao; Masuda, Takashi; Maeda, Ryutaro; Itoh, Toshihiro
2012-09-01
An animal health monitoring system and a wireless sensor node aimed at preventing the spread of animal-transmitted diseases and improving pastoral efficiency which are especially suitable for chickens, were developed. The sensor node uses a piezoelectric microelectromechanical system (MEMS) device and an event-driven system that is activated by the movements of a chicken. The piezoelectric MEMS device has two functions: a) it measures the activity of a chicken and b) switches the micro-control unit (MCU) of the wireless sensor node from the sleep mode. The piezoelectric MEMS device is required to produce high output voltages when the chicken moves. However, after the piezoelectric MEMS device was reflowed to the wireless sensor node, the output voltages of the piezoelectric MEMS device decreased. The main reason for this might be the loss of residual polarization, which is affected by the thermal load during the reflow process. After the reflow process, we were not able to apply a voltage to the piezoelectric MEMS device; thus, the piezoelectric output voltage was not increased by repoling the piezoelectric MEMS device. To address the thermal load of the reflow process, we established a thermal poling treatment, which achieves a higher temperature than the reflow process. We found that on increasing the thermal poling temperature, the piezoelectric output voltages did not decreased low significantly. Thus, we considered that a thermal poling temperature higher than that of the reflow process prevents the piezoelectric output voltage reduction caused by the thermal load.
Miao, Fen; Cheng, Yayu; He, Yi; He, Qingyun; Li, Ye
2015-05-19
Continuously monitoring the ECG signals over hours combined with activity status is very important for preventing cardiovascular diseases. A traditional ECG holter is often inconvenient to carry because it has many electrodes attached to the chest and because it is heavy. This work proposes a wearable, low power context-aware ECG monitoring system integrated built-in kinetic sensors of the smartphone with a self-designed ECG sensor. The wearable ECG sensor is comprised of a fully integrated analog front-end (AFE), a commercial micro control unit (MCU), a secure digital (SD) card, and a Bluetooth module. The whole sensor is very small with a size of only 58 × 50 × 10 mm for wearable monitoring application due to the AFE design, and the total power dissipation in a full round of ECG acquisition is only 12.5 mW. With the help of built-in kinetic sensors of the smartphone, the proposed system can compute and recognize user's physical activity, and thus provide context-aware information for the continuous ECG monitoring. The experimental results demonstrated the performance of proposed system in improving diagnosis accuracy for arrhythmias and identifying the most common abnormal ECG patterns in different activities. In conclusion, we provide a wearable, accurate and energy-efficient system for long-term and context-aware ECG monitoring without any extra cost on kinetic sensor design but with the help of the widespread smartphone.
Analysis of multiple cell upset sensitivity in bulk CMOS SRAM after neutron irradiation
NASA Astrophysics Data System (ADS)
Pan, Xiaoyu; Guo, Hongxia; Luo, Yinhong; Zhang, Fengqi; Ding, Lili
2018-03-01
In our previous studies, we have proved that neutron irradiation can decrease the single event latch-up (SEL) sensitivity of CMOS SRAM. And one of the key contributions to the multiple cell upset (MCU) is the parasitic bipolar amplification, it bring us to study the impact of neutron irradiation on the SRAM’s MCU sensitivity. After the neutron experiment, we test the devices’ function and electrical parameters. Then, we use the heavy ion fluence to examine the changes on the devices’ MCU sensitivity pre- and post-neutron-irradiation. Unfortunately, neutron irradiation makes the MCU phenomenon worse. Finally, we use the electric static discharge (ESD) testing technology to deduce the experimental results and find that the changes on the WPM region take the lead rather than the changes on the parasitic bipolar amplification for the 90 nm process.
Remote multi-function fire alarm system based on internet of things
NASA Astrophysics Data System (ADS)
Wang, Lihui; Zhao, Shuai; Huang, Jianqing; Ji, Jianyu
2018-05-01
This project uses MCU STC15W408AS (stable, energy saving, high speed), temperature sensor DS18B20 (cheap, high efficiency, stable), MQ2 resistance type semiconductor smog sensor (high stability, fast response and economy) and NRF24L01 wireless transmitting and receiving module (energy saving, small volume, reliable) as the main body to achieve concentration temperature data presentation, intelligent voice alarming and short distance wireless transmission. The whole system is safe, reliable, cheap, quick reaction and good performance. This project uses the MCU STM32F103RCT6 as the main control chip, and use WIFI module ESP8266, wireless module NRF24L01 to make the gateway. Users can remotely check and control the related devices in real-time on smartphones or computers. We can also realize the functions of intelligent fire monitoring, remote fire extinguishing, cloud data storage through the third party server Big IOT.
NASA Astrophysics Data System (ADS)
Coffey, Stephen; Connell, Joseph
2005-06-01
This paper presents a development platform for real-time image processing based on the ADSP-BF533 Blackfin processor and the MicroC/OS-II real-time operating system (RTOS). MicroC/OS-II is a completely portable, ROMable, pre-emptive, real-time kernel. The Blackfin Digital Signal Processors (DSPs), incorporating the Analog Devices/Intel Micro Signal Architecture (MSA), are a broad family of 16-bit fixed-point products with a dual Multiply Accumulate (MAC) core. In addition, they have a rich instruction set with variable instruction length and both DSP and MCU functionality thus making them ideal for media based applications. Using the MicroC/OS-II for task scheduling and management, the proposed system can capture and process raw RGB data from any standard 8-bit greyscale image sensor in soft real-time and then display the processed result using a simple PC graphical user interface (GUI). Additionally, the GUI allows configuration of the image capture rate and the system and core DSP clock rates thereby allowing connectivity to a selection of image sensors and memory devices. The GUI also allows selection from a set of image processing algorithms based in the embedded operating system.
An inductive narrow-pulse RFID telemetry system for gastric slow waves monitoring.
Javan-Khoskholgh, Amir; Abukhalaf, Zaid; Ji Li; Miller, Larry S; Kiani, Mehdi; Farajidavar, Aydin
2016-08-01
We present a passive data telemetry system for real-time monitoring of gastric electrical activity of a living subject. The system is composed of three subsystems: an implantable unit (IU), a wearable unit (WU), and a stationary unit (SU). Data communication between the IU and WU is based on a radio-frequency identification (RFID) link operating at 13.56 MHz. Since wireless power transmission and reverse data telemetry system share the same inductive interface, a load shift keying (LSK)-based differential pulse position (DPP) coding data communication with only 6.25% duty cycle is developed to guarantee consistent wireless downlink power transmission and uplink high data transfer rate, simultaneously. The clock and data are encoded into one signal by an MSP430 microcontroller (MCU) at the IU side. This signal is sent to the WU through the inductive link, where decoded by an MSP432 MCU. Finally, the retrieved data at the WU are transmitted to the SU connected to a PC via a 2.4 GHz transceiver for real-time display and analysis. The results of the measurements on the implemented test bench, demonstrate IU-WU 125 kb/s and WU-SU 2 Mb/s data transmission rate with no observed mismatch, while the data stream was randomly generated, and matching between the transmitted data by the IU and received by the SU verified by a custom-made automated software.
The I-V Measurement System for Solar Cells Based on MCU
NASA Astrophysics Data System (ADS)
Fengxiang, Chen; Yu, Ai; Jiafu, Wang; Lisheng, Wang
2011-02-01
In this paper, an I-V measurement system for solar cells based on Single-chip Microcomputer (MCU) is presented. According to the test principles of solar cells, this measurement system mainly comprises of two parts—data collecting, data processing and displaying. The MCU mainly used as to acquire data, then the collecting results is sent to the computer by serial port. The I-V measurement results of our test system are shown in the human-computer interaction interface based on our hardware circuit. By comparing the test results of our I-V tester and the results of other commercial I-V tester, we found errors for most parameters are less than 5%, which shows our I-V test result is reliable. Because the MCU can be applied in many fields, this I-V measurement system offers a simple prototype for portable I-V tester for solar cells.
Hamerschmidt, Rogério; Schuch, Luiz Henrique; Rezende, Rodrigo Kopp; Wiemes, Gislaine Richter Minhoto; Oliveira, Adriana Kosma Pires de; Mocellin, Marcos
2012-01-01
There are two techniques for cochlear implant (CI) electrode placement: cochleostomy and the round window (RW) approach. This study aims to compare neural response telemetry (NRT) results immediately after surgery to check for possible differences on auditory nerve stimulation between these two techniques. This is a prospective cross-sectional study. Twenty-three patients were enrolled. Six patients underwent surgery by cochleostomy and 17 had it through the RW approach. Mean charge units (MCU) for high frequency sounds: patients submitted to the RW approach had a mean value of 190.4 (± 29.2) while cochleostomy patients averaged 187.8 (± 32.7); p = 0.71. MCU for mid frequency sounds: patients submitted to the RW approach had a mean value of 192.5 (± 22) while cochleostomy patients averaged 178.5 (± 18.5); p = 0.23. MCU for low frequency sounds: patients submitted to the RW approach had a mean value of 183.3 (± 25) while cochleostomy patients averaged 163.8 (± 19.3); p = 0.19. This study showed no differences in the action potential of the distal portion of the auditory nerve in patients with multichannel cochlear implants submitted to surgery by cochleostomy or through the RW approach, using the implant itself to generate stimuli and record responses. Both techniques equally stimulate the cochlear nerve. Therefore, the choice of approach can be made based on the surgeon's own preference and experience.
ISDP salt batch #2 supernate qualification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, T. B.; Nash, C. A.; Fink, S. D.
2009-01-05
This report covers the laboratory testing and analyses of the second Integrated Salt Disposition Project (ISDP) salt supernate samples, performed in support of initial radioactive operations of Actinide Removal Process (ARP) and Modular Caustic-Side Solvent Extraction Unit (MCU). Major goals of this work include characterizing Tank 22H supernate, characterizing Tank 41H supernate, verifying actinide and strontium adsorption with a standard laboratory-scale test using monosodium titanate (MST) and filtration, and checking cesium mass transfer behavior for the MCU solvent performance when contacted with the liquid produced from MST contact. This study also includes characterization of a post-blend Tank 49H sample asmore » part of the Nuclear Criticality Safety Evaluation (NCSE). This work was specified by Task Technical Request and by Task Technical and Quality Assurance Plan (TTQAP). In addition, a sampling plan will be written to guide analytical future work. Safety and environmental aspects of the work were documented in a Hazard Assessment Package.« less
Informal interprofessional learning: visualizing the clinical workplace.
Wagter, Judith Martine; van de Bunt, Gerhard; Honing, Marina; Eckenhausen, Marina; Scherpbier, Albert
2012-05-01
Daily collaboration of senior doctors, residents and nurses involves a major potential for sharing knowledge between professionals. Therefore, more attention needs to be paid to informal learning to create strategies and appropriate conditions for enhancing and effectuating informal learning in the workplace. The aim of this study is to visualize and describe patterns of informal interprofessional learning relations among staff in complex care. Questionnaires with four network questions - recognized as indicators of informal learning in the clinical workplace - were handed out to intensive and medium care unit (ICU/MCU) staff members (N = 108), of which 77% were completed and returned. Data were analyzed using social network analysis and Mokken scale analysis. Densities, tie strength and reciprocity of the four networks created show MCU and ICU nurses as subgroups within the ward and reveal central but relatively one-sided relations of senior doctors with nurses and residents. Based on the analyses, we formulated a scale of intensity of informal learning relations that can be used to understand and stimulate informal interprofessional learning.
m-AAA proteases, mitochondrial calcium homeostasis and neurodegeneration
Patron, Maria; Sprenger, Hans-Georg; Langer, Thomas
2018-01-01
The function of mitochondria depends on ubiquitously expressed and evolutionary conserved m-AAA proteases in the inner membrane. These ATP-dependent peptidases form hexameric complexes built up of homologous subunits. AFG3L2 subunits assemble either into homo-oligomeric isoenzymes or with SPG7 (paraplegin) subunits into hetero-oligomeric proteolytic complexes. Mutations in AFG3L2 are associated with dominant spinocerebellar ataxia (SCA28) characterized by the loss of Purkinje cells, whereas mutations in SPG7 cause a recessive form of hereditary spastic paraplegia (HSP7) with motor neurons of the cortico-spinal tract being predominantly affected. Pleiotropic functions have been assigned to m-AAA proteases, which act as quality control and regulatory enzymes in mitochondria. Loss of m-AAA proteases affects mitochondrial protein synthesis and respiration and leads to mitochondrial fragmentation and deficiencies in the axonal transport of mitochondria. Moreover m-AAA proteases regulate the assembly of the mitochondrial calcium uniporter (MCU) complex. Impaired degradation of the MCU subunit EMRE in AFG3L2-deficient mitochondria results in the formation of deregulated MCU complexes, increased mitochondrial calcium uptake and increased vulnerability of neurons for calcium-induced cell death. A reduction of calcium influx into the cytosol of Purkinje cells rescues ataxia in an AFG3L2-deficient mouse model. In this review, we discuss the relationship between the m-AAA protease and mitochondrial calcium homeostasis and its relevance for neurodegeneration and describe a novel mouse model lacking MCU specifically in Purkinje cells. Our results pledge for a novel view on m-AAA proteases that integrates their pleiotropic functions in mitochondria to explain the pathogenesis of associated neurodegenerative disorders. PMID:29451229
m-AAA proteases, mitochondrial calcium homeostasis and neurodegeneration.
Patron, Maria; Sprenger, Hans-Georg; Langer, Thomas
2018-03-01
The function of mitochondria depends on ubiquitously expressed and evolutionary conserved m-AAA proteases in the inner membrane. These ATP-dependent peptidases form hexameric complexes built up of homologous subunits. AFG3L2 subunits assemble either into homo-oligomeric isoenzymes or with SPG7 (paraplegin) subunits into hetero-oligomeric proteolytic complexes. Mutations in AFG3L2 are associated with dominant spinocerebellar ataxia (SCA28) characterized by the loss of Purkinje cells, whereas mutations in SPG7 cause a recessive form of hereditary spastic paraplegia (HSP7) with motor neurons of the cortico-spinal tract being predominantly affected. Pleiotropic functions have been assigned to m-AAA proteases, which act as quality control and regulatory enzymes in mitochondria. Loss of m-AAA proteases affects mitochondrial protein synthesis and respiration and leads to mitochondrial fragmentation and deficiencies in the axonal transport of mitochondria. Moreover m-AAA proteases regulate the assembly of the mitochondrial calcium uniporter (MCU) complex. Impaired degradation of the MCU subunit EMRE in AFG3L2-deficient mitochondria results in the formation of deregulated MCU complexes, increased mitochondrial calcium uptake and increased vulnerability of neurons for calcium-induced cell death. A reduction of calcium influx into the cytosol of Purkinje cells rescues ataxia in an AFG3L2-deficient mouse model. In this review, we discuss the relationship between the m-AAA protease and mitochondrial calcium homeostasis and its relevance for neurodegeneration and describe a novel mouse model lacking MCU specifically in Purkinje cells. Our results pledge for a novel view on m-AAA proteases that integrates their pleiotropic functions in mitochondria to explain the pathogenesis of associated neurodegenerative disorders.
Strategic Positioning and Biased Activity of the Mitochondrial Calcium Uniporter in Cardiac Muscle*
De La Fuente, Sergio; Fernandez-Sanz, Celia; Vail, Caitlin; Agra, Elorm J.; Holmstrom, Kira; Sun, Junhui; Mishra, Jyotsna; Williams, Dewight; Finkel, Toren; Murphy, Elizabeth; Joseph, Suresh K.; Sheu, Shey-Shing; Csordás, György
2016-01-01
Control of myocardial energetics by Ca2+ signal propagation to the mitochondrial matrix includes local Ca2+ delivery from sarcoplasmic reticulum (SR) ryanodine receptors (RyR2) to the inner mitochondrial membrane (IMM) Ca2+ uniporter (mtCU). mtCU activity in cardiac mitochondria is relatively low, whereas the IMM surface is large, due to extensive cristae folding. Hence, stochastically distributed mtCU may not suffice to support local Ca2+ transfer. We hypothesized that mtCU concentrated at mitochondria-SR associations would promote the effective Ca2+ transfer. mtCU distribution was determined by tracking MCU and EMRE, the proteins essential for channel formation. Both proteins were enriched in the IMM-outer mitochondrial membrane (OMM) contact point submitochondrial fraction and, as super-resolution microscopy revealed, located more to the mitochondrial periphery (inner boundary membrane) than inside the cristae, indicating high accessibility to cytosol-derived Ca2+ inputs. Furthermore, MCU immunofluorescence distribution was biased toward the mitochondria-SR interface (RyR2), and this bias was promoted by Ca2+ signaling activity in intact cardiomyocytes. The SR fraction of heart homogenate contains mitochondria with extensive SR associations, and these mitochondria are highly enriched in EMRE. Size exclusion chromatography suggested for EMRE- and MCU-containing complexes a wide size range and also revealed MCU-containing complexes devoid of EMRE (thus disabled) in the mitochondrial but not the SR fraction. Functional measurements suggested more effective mtCU-mediated Ca2+ uptake activity by the mitochondria of the SR than of the mitochondrial fraction. Thus, mtCU “hot spots” can be formed at the cardiac muscle mitochondria-SR associations via localization and assembly bias, serving local Ca2+ signaling and the excitation-energetics coupling. PMID:27637331
Solvent hold tank sample results for MCU-16-1247-1248-1249: August 2016 monthly sample
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fondeur, F. F.; Jones, D. H.
Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-16-1247-1248-1249), pulled on 08/22/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-1247-1248-1249 indicated the Isopar™L concentration is above its nominal level (101%). The extractant (MaxCalix) and the modifier (CS-7SB) are 7% and 9 % below their nominal concentrations. The suppressor (TiDG) is 63% below its nominal concentration. A summary of the concentration of the relevant solvent components is shown below.
Impact of axial velocity and transmembrane pressure (TMP) on ARP filter performance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poirier, M.; Burket, P.
2016-02-29
The Savannah River Site (SRS) is currently treating radioactive liquid waste with the Actinide Removal Process (ARP) and the Modular Caustic Side Solvent Extraction Unit (MCU). Recently, the low filter flux through the ARP of approximately 5 gallons per minute has limited the rate at which radioactive liquid waste can be treated. Salt Batch 6 had a lower processing rate and required frequent filter cleaning. Savannah River Remediation (SRR) has a desire to understand the causes of the low filter flux and to increase ARP/MCU throughput. One potential method for increasing filter flux is to adjust the axial velocity andmore » transmembrane pressure (TMP). SRR requested SRNL to conduct bench-scale filter tests to evaluate the effects of axial velocity and transmembrane pressure on crossflow filter flux. The objective of the testing was to determine whether increasing the axial velocity at the ARP could produce a significant increase in filter flux. The authors conducted the tests by preparing slurries containing 6.6 M sodium Salt Batch 6 supernate and 2.5 g MST/L, processing the slurry through a bench-scale crossflow filter unit at varying axial velocity and TMP, and measuring filter flux as a function of time.« less
Real-Time Telemetry System for Amperometric and Potentiometric Electrochemical Sensors
Wang, Wei-Song; Huang, Hong-Yi; Chen, Shu-Chun; Ho, Kuo-Chuan; Lin, Chia-Yu; Chou, Tse-Chuan; Hu, Chih-Hsien; Wang, Wen-Fong; Wu, Cheng-Feng; Luo, Ching-Hsing
2011-01-01
A real-time telemetry system, which consists of readout circuits, an analog-to-digital converter (ADC), a microcontroller unit (MCU), a graphical user interface (GUI), and a radio frequency (RF) transceiver, is proposed for amperometric and potentiometric electrochemical sensors. By integrating the proposed system with the electrochemical sensors, analyte detection can be conveniently performed. The data is displayed in real-time on a GUI and optionally uploaded to a database via the Internet, allowing it to be accessed remotely. An MCU was implemented using a field programmable gate array (FPGA) to filter noise, transmit data, and provide control over peripheral devices to reduce power consumption, which in sleep mode is 70 mW lower than in operating mode. The readout circuits, which were implemented in the TSMC 0.18-μm CMOS process, include a potentiostat and an instrumentation amplifier (IA). The measurement results show that the proposed potentiostat has a detectable current range of 1 nA to 100 μA, and linearity with an R2 value of 0.99998 in each measured current range. The proposed IA has a common-mode rejection ratio (CMRR) greater than 90 dB. The proposed system was integrated with a potentiometric pH sensor and an amperometric nitrite sensor for in vitro experiments. The proposed system has high linearity (an R2 value greater than 0.99 was obtained in each experiment), a small size of 5.6 cm × 8.7 cm, high portability, and high integration. PMID:22164093
Real-time telemetry system for amperometric and potentiometric electrochemical sensors.
Wang, Wei-Song; Huang, Hong-Yi; Chen, Shu-Chun; Ho, Kuo-Chuan; Lin, Chia-Yu; Chou, Tse-Chuan; Hu, Chih-Hsien; Wang, Wen-Fong; Wu, Cheng-Feng; Luo, Ching-Hsing
2011-01-01
A real-time telemetry system, which consists of readout circuits, an analog-to-digital converter (ADC), a microcontroller unit (MCU), a graphical user interface (GUI), and a radio frequency (RF) transceiver, is proposed for amperometric and potentiometric electrochemical sensors. By integrating the proposed system with the electrochemical sensors, analyte detection can be conveniently performed. The data is displayed in real-time on a GUI and optionally uploaded to a database via the Internet, allowing it to be accessed remotely. An MCU was implemented using a field programmable gate array (FPGA) to filter noise, transmit data, and provide control over peripheral devices to reduce power consumption, which in sleep mode is 70 mW lower than in operating mode. The readout circuits, which were implemented in the TSMC 0.18-μm CMOS process, include a potentiostat and an instrumentation amplifier (IA). The measurement results show that the proposed potentiostat has a detectable current range of 1 nA to 100 μA, and linearity with an R2 value of 0.99998 in each measured current range. The proposed IA has a common-mode rejection ratio (CMRR) greater than 90 dB. The proposed system was integrated with a potentiometric pH sensor and an amperometric nitrite sensor for in vitro experiments. The proposed system has high linearity (an R2 value greater than 0.99 was obtained in each experiment), a small size of 5.6 cm × 8.7 cm, high portability, and high integration.
Solvent hold tank sample results for MCU-16-1317-1318-1319: September 2016 monthly sample
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fondeur, F. F.; Jones, D. H.
Savannah River National Laboratory (SRNL) received one set of three Solvent Hold Tank (SHT) samples (MCU-16-1317-1318-1319), pulled on 09/12/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-1317-1318-1319 indicated the Isopar™L concentration is above its nominal level (102%). The extractant (MaxCalix) and the modifier (CS-7SB) are 5% and 9% below their nominal concentrations. The suppressor (TiDG) is 76% below its nominal concentration. A summary of the concentration of the relevant solvent components is shown below.
Solvent hold tank sample results for MCU-16-1363-1364-1365: November 2016 monthly sample
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fondeur, F. F.; Jones, D. H.
Savannah River National Laboratory (SRNL) received one set of three Solvent Hold Tank (SHT) samples (MCU-16-1363-1364-1365), pulled on 11/15/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-1363-1364-1365 indicated the Isopar™L concentration is at its nominal level (100%). The extractant (MaxCalix) and the modifier (CS- 7SB) are 8% and 2 % below their nominal concentrations. The suppressor (TiDG) is 7% below its nominal concentration. A summary of the concentration of the relevant solvent components is shown below.
A three-channel LED driver with single line transportation technique
NASA Astrophysics Data System (ADS)
Yu, Caideng; Du, Yiying; Jiang, Qiao; Zhou, Yun; Lv, Jian
2012-10-01
Designed a three-channel LED driver, realized the single-wire transmission of cascade signal between the drive IC of LED. Including the MCU digital interface, date register, clock synchronization, PWM grayscale adjustment circuit, as well as high voltage driver circuit for LED, etc… The driver control LED displaying 256 gray. Chip will generate synchronous sampling clock signals according to the received serial signals, when 24 bits dates have been received, the output pin begins to transport the dates followed-up which are automotive shaped to the input of the next chip. When the date receiving becomes low level that represent RESET, the red, green and blue channels will export different signals based on different input dates. Through the external MCU, it is realized the Separate luminance, and by connecting chips in series it achieved the control of outdoor big screen' colorful display. The automatic shaping forward technique makes the number of chips cascading immune to the limitations of signal transmission, but only limited by the refresh speed.
NASA Astrophysics Data System (ADS)
Huang, Hong-bin; Liu, Wei-ping; Chen, Shun-er; Zheng, Liming
2005-02-01
A new type of CATV network management system developed by universal MCU, which supports SNMP, is proposed in this paper. From the point of view in both hardware and software, the function and method of every modules inside the system, which include communications in the physical layer, protocol process, data process, and etc, are analyzed. In our design, the management system takes IP MAN as data transmission channel and every controlled object in the management structure has a SNMP agent. In the SNMP agent developed, there are four function modules, including physical layer communication module, protocol process module, internal data process module and MIB management module. In the paper, the structure and function of every module are designed and demonstrated while the related hardware circuit, software flow as well as the experimental results are tested. Furthermore, by introducing RTOS into the software programming, the universal MCU procedure can conducts such multi-thread management as fast Ethernet controller driving, TCP/IP process, serial port signal monitoring and so on, which greatly improves efficiency of CPU.
Solvent Hold Tank Sample Results For MCU-15-750-751-752-: June Monthly Sample
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fondeur, F.; Taylor-Pashow, K.
2015-10-07
Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-15-750, MCU-15-751, and MCU-15-752), pulled on 06/22/2015 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-15-750-751-752 indicated a low concentration (~ 49 % of nominal) of the suppressor (TiDG) and slightly lower than nominal concentrations of the extractant (MaxCalix), and of the modifier (Cs-7SB) in the solvent. This analysis confirms the addition of TiDG, MaxCalix, and modifier to the solvent in February 2015. Based on the current monthly sample, the levels of TiDG, MaxCalix, and modifier are sufficient formore » continuing operation without adding a trim at this time but it is recommended that an addition of TiDG, modifier and Isopar™L should be made in the near future. No impurities above the 1000 ppm level were found in this solvent by the Semi-Volatile Organic Analysis (SVOA). No impurities were observed in the Hydrogen Nuclear Magnetic Resonance (HNMR). In addition, up to 13.9 micrograms of mercury per gram of solvent (or 11.5 µg/mL) was detected in this sample. The laboratory will continue to monitor the quality of the solvent in particular for any new impurities or degradation of the solvent components.« less
Implementation of Bluetooth technology in processing aspheric mirrors
NASA Astrophysics Data System (ADS)
Chen, Dong-yun; Li, Xiao-jin
2010-10-01
This paper adopts the Bluetooth wireless transmission to replace the conducting rings currently using in the active lap process to overcome the cost and abrasion problems brought by the conducting rings, which has great significance for reducing the costs of processing large aspheric mirrors. Based on the actual application requirements, Article proposes the overall program of using Bluetooth technology as data transmission, including the active lap-side and machine tool-side: In the machine tool-side, the MCU separately connects with Bluetooth module and the sensor via UART0 and UART1 serial port, and when the MCU receives the signals sending from the sensor, the MCU packs and then sends them through the Bluetooth module; while in the active lap side, the CCAL reads-out the position signals of sensor detecting in dual-port memory via one-side ports, and the other side ports connect with the MCU's high ports P4-P7, so the MCU can unpacks and stores the position signals receiving via Bluetooth module. This paper designs and implements the system's hardware circuit, and mainly introduces the ways of serial and parallel. Based upon the realized system, design the test program for the Bluetooth wireless transmission and the experiment results, in the condition of the active lap processing large aspheric mirrors, showed that Bluetooth technology can meet the requirements of practical applications.
A Smart High Accuracy Silicon Piezoresistive Pressure Sensor Temperature Compensation System
Zhou, Guanwu; Zhao, Yulong; Guo, Fangfang; Xu, Wenju
2014-01-01
Theoretical analysis in this paper indicates that the accuracy of a silicon piezoresistive pressure sensor is mainly affected by thermal drift, and varies nonlinearly with the temperature. Here, a smart temperature compensation system to reduce its effect on accuracy is proposed. Firstly, an effective conditioning circuit for signal processing and data acquisition is designed. The hardware to implement the system is fabricated. Then, a program is developed on LabVIEW which incorporates an extreme learning machine (ELM) as the calibration algorithm for the pressure drift. The implementation of the algorithm was ported to a micro-control unit (MCU) after calibration in the computer. Practical pressure measurement experiments are carried out to verify the system's performance. The temperature compensation is solved in the interval from −40 to 85 °C. The compensated sensor is aimed at providing pressure measurement in oil-gas pipelines. Compared with other algorithms, ELM acquires higher accuracy and is more suitable for batch compensation because of its higher generalization and faster learning speed. The accuracy, linearity, zero temperature coefficient and sensitivity temperature coefficient of the tested sensor are 2.57% FS, 2.49% FS, 8.1 × 10−5/°C and 29.5 × 10−5/°C before compensation, and are improved to 0.13%FS, 0.15%FS, 1.17 × 10−5/°C and 2.1 × 10−5/°C respectively, after compensation. The experimental results demonstrate that the proposed system is valid for the temperature compensation and high accuracy requirement of the sensor. PMID:25006998
LITERATURE REVIEW OF BORIC ACID SOLUBILITY DATA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Crapse, K.; Kyser, E.
2011-09-22
A new solvent system is being evaluated for use in the Modular Caustic-Side Solvent Extraction Unit (MCU) and in the Salt Waste Processing Facility (SWPF). The new system replaces the current dilute nitric acid strip solution with 0.01 M boric acid. This literature study is performed to determine if there is a potential for boric acid to crystallize in the lines with emphasis on the transfer lines to the Defense Waste Processing Facility. This report focuses on the aqueous phase chemistry of boric acid under conditions relevant to MCU and SWPF. Operating and transfer conditions examined for the purpose ofmore » this review include temperatures between 13 C (McLeskey, 2008) and 45 C (Fondeur, 2007) and concentrations from 0 to 3M in nitric acid as well as exposure of small amounts of entrained boric acid in the organic phase to the sodium hydroxide caustic wash stream. Experiments were also conducted to observe any chemical reactions and off-gas generation that could occur when 0.01 M boric acid solution mixes with 3 M nitric acid solution and vice versa. Based on the low concentration (0.01M) of boric acid in the MCU/SWPF strip acid and the moderate operating temperatures (13 C to 45 C), it is unlikely that crystallization of boric acid will occur in the acid strip solution under process or transfer conditions. Mixing experiments of boric and nitric acid show no measurable gas generation (< 1 cc of gas per liter of solution) under similar process conditions.« less
Optimal Micro-Vane Flow Control for Compact Air Vehicle Inlets
NASA Technical Reports Server (NTRS)
Anderson, Bernhard H.; Miller, Daniel N.; Addington, Gregory A.; Agrell, Johan
2004-01-01
The purpose of this study on micro-vane secondary flow control is to demonstrate the viability and economy of Response Surface Methodology (RSM) to optimally design micro-vane secondary flow control arrays, and to establish that the aeromechanical effects of engine face distortion can also be included in the design and optimization process. These statistical design concepts were used to investigate the design characteristics of "low unit strength" micro-effector arrays. "Low unit strength" micro-effectors are micro-vanes set at very low angles-of-incidence with very long chord lengths. They were designed to influence the near wall inlet flow over an extended streamwise distance, and their advantage lies in low total pressure loss and high effectiveness in managing engine face distortion. Therefore, this report examines optimal micro-vane secondary flow control array designs for compact inlets through a Response Surface Methodology.
Electrical Power Subsystem Integration and Test for the NPS Solar Cell Array Tester CubeSat
2010-12-01
Earth’s Gravitational Constant MCU Microcontroller Unit MPPT Maximum Power Point Tracker NiCr Nickel Chromium NPS Naval Postgraduate School P...new testing platform was designed, built, and used to conduct integrated testing on CubeSat Kit (CSK) compatible devices. The power budgets and...acceptance test results obtained from the testing platform were used with a solar array power generation simulation, and a battery state of charge
The Need to Increase Marine Corps Special Operations Command
2009-01-01
Operations University presentation by Major Mark Raney for USSOCOM elective (lecture, MCU, Quantico VA, 17 Feb 20Q9). 5 Stew Magnuson, "Marine Special...2008 Posture Statement.doc (Accessed 23 December, 2008) 20 David Tucker and Christopher J. Lamb , United States Special Operations Forces (New York...invasion of Afghanistan encroached on the Marine Corps historical role of being "soldiers from the sea." 38 David Tucker and Christopher J. lamb , 182
A Green Protocol for Synthesis of MAl2O4, [M=Cu and Co] Spinels Under Microwave Irradiation Method
NASA Astrophysics Data System (ADS)
Yuvasravana, R.; George, P. P.
Nanosized metal aluminates MAl2O4, [M=Cu and Co] are synthesized from their nitrates solution by using pomegranate peel extract as fuel in microwave combustion. MAl2O4 [M=Cu and Co] nanoparticles are grown in microwave assisted synthesis followed by annealing at 700∘C. The nanoparticles have been characterized by powder X-ray diffraction (PXRD), scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR), UV-VIS spectroscopy and photoluminescence (PL) spectroscopy. The PXRD analysis has confirmed their spinel composition. The green protocol and microwave combustion route for spinel synthesis are rapid, simple, without any hazardous chemicals as reducing or stabilizing agents and economical.
Origin of reduced efficiency in high Ga concentration Cu(In,Ga)Se2 solar cell
NASA Astrophysics Data System (ADS)
Wei, S.-H.; Huang, B.; Deng, H.; Contreras, M. A.; Noufi, R.; Chen, S.; Wang, L. W.
2014-03-01
CuInSe2 (CIS) is one of the most attractive thin-film materials for solar cells. It is well know that alloying Ga into CIS forming Cu(In,Ga)Se2 (CIGS) alloy is crucial to achieve the high efficiency, but adding too much Ga will lead to a decline of the solar cell efficiency. The exact origin of this puzzling phenomenon is currently still under debate. Using first-principles method, we have systemically studied the structural and electronic properties of CIGS alloys. Our phase diagram calculations suggest that increasing growth temperature may not be a critical factor in enhancing the cell performance of CIGS under equilibrium growth condition. On the other hand, our defect calculations identify that high concentration of antisite defects MCu(M =In, Ga) rather than anion defects are the key deep-trap centers in CIGS. The more the Ga concentration in CIGS, the more harmful the deep-trap is. Self-compensation in CIGS, which forms 2VCu + MCudefect complexes, is found to be beneficial to quench the deep-trap levels induced by MCu in CIGS, especially at low Ga concentration. Unfortunately, the density of isolated MCu is quite high and cannot be largely converted into 2VCu + MCu complexes under thermal equilibrium condition. Thus, nonequilibrium growth conditions or low growth temperature that can suppress the formation of the deep-trap centers MCu may be necessary for improving the efficiency of CIGS solar cells with high Ga concentrations.
2012-01-01
Introduction Little is known regarding the association between socioeconomic factors and contraceptive use in the Newly Independent States (NIS), countries that have experienced profound changes in reproductive health services during the transition from socialism to a market economy. Methods Using 2005–2006 data from Demographic Health Surveys (Armenia, Azerbaijan, and Moldova) and Multiple Indicator Cluster Surveys (Belarus, Georgia, Kazakhstan, Kyrgyzstan, Tajikistan, Ukraine, and Uzbekistan), we examined associations between individual and community socioeconomic status with current modern contraceptive use (MCU) among N = 55,204 women aged 15–49 married or in a union. Individual socioeconomic status was measured using quintiles of wealth index and education level (higher than secondary school, secondary school or less). Community socioeconomic status was measured as the percentage of households in the poorest quintile of the nationals household wealth index (0%, 0–25%, or greater than 25%). We used multilevel logistic regression to estimate associations adjusted for age, number of children, urban/rural, and socioeconomic variables. Results MCU varied by country from 14% (in Azerbaijan) to 62% (in Belarus). Overall, women living in the poorest communities were less likely than those in the richest to use modern contraceptives (adjusted odds ratio (aOR) = 0.82, 95% Confidence Interval = 0.76, 0.89). Similarly, there was an increasing odds of MCU with increasing individual-level wealth. Women with a lower level of education also had lower odds of MCU than those with a higher level of education (aOR = .75, 95%CI = 0.71, 0.79). In country-specific analyses, community-level socioeconomic inequalities were apparent in 4 of 10 countries; in contrast, inequalities by individual-level wealth were apparent in 7 countries and by education in 8 countries. All countries in which community-level socioeconomic status was associated with MCU were in Central Asia, whereas at the individual-level inequalities of the largest magnitude were found in the Caucasus. There were no distinct patterns found in Eastern European countries. Conclusions Community-level socioeconomic inequalities in MCU were most pronounced in Central Asian countries, whereas individual-level socioeconomic inequalities in MCU were most pronounced in the Caucasus. It is important to consider multilevel contextual determinants of modern contraceptive use in the development of reproductive health and family planning programs. PMID:23158261
Equilibrium studies of oxalate and aluminum containing solutions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hay, M. S.; King, W. D.; Peters, T. B.
2015-11-01
The Savannah River National Laboratory (SRNL) was tasked to develop data on the solubility and conditions leading to precipitation of sodium oxalate, sodium nitrate, Bayerite (a polymorph of gibbsite, Al(OH) 3), and sodium aluminosilicate solids recently found in the Modular Caustic Side Solvent Extraction Unit (MCU). The data generated will be used to improve the OLI Systems thermodynamic database for these compounds allowing better prediction of solids formation by the modeling software in the future.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fondeur, F. F.
On June 2015, Savannah River National Laboratory (SRNL) received a Strip Effluent (SE) coalescer (FLT-304) from MCU. That coalescer was first installed at MCU in late October 2014 and removed in April 2015. While processing approximately 48,700 gallons of strip solution, the pressure drop steadily increased linearly from 1 psi to near 16 psi (the administrative limit is 17 psi) with the total filtrate volume (2.1E-4 psi/gal of filtrate). The linear behavior is due to the combined effect of a constant deposition of material that starts from the closed-end to the mid-section of the coalescer reducing the available surface areamore » of the coalescer for fluid passage (linearly with filtrate volume) and the formation of a secondary emulsion (water in NG-CSSX) on the fibers of the coalescer media. Both effects reduced the coalescer porosity by at least 13% (after processing 48,700 gallons). Before the coalescer was removed, it was flushed with a 10 mM boric acid solution to reduce the dose level. To determine the nature of the deposited material, a physical and chemical analysis of the coalescer was conducted. Characterization of this coalescer revealed the adsorption of organic containing amines (secondary amides and primary amines), TiDG, degraded modifier (with no hydroxyl group), MaxCalix, and oxidized hydrocarbon (possibly from Isopar™L or from lubricant used at MCU) onto the coalescer media. The amide and amines are possibly from the decomposition of the suppressor (TiDG). The modifier and MaxCalix were the largest components of the deposited organic material, as determined from leaching the coalescer with dichloromethane. Both the Fourier-Transformed Infrared (FTIR) and Fourier-Transformed Hydrogen Nuclear Magnetic Resonance (FT-HNMR) results indicated that some of the modifier was degraded (missing their OH groups). The modifier was observed everywhere in the examined coalescer pieces (FTIR), while the TiDG and its decomposition products were observed at the entrance discs of the coalescer. A solvent trim (a cocktail of solvent components with a high concentration of modifier) was added to the solvent on 2/22/2015. It is believed that the trim did not mix completely with the solvent and that it was subsequently spread around the MCU components including the coalescers, where it may have deposited. Chronologically, the modifier, the TiDG’s decomposition products and silicates deposited on the entrance discs first and after the pressure drop increased significantly, parts of the coalescer media detached itself from the central porous steel mandrel and a significant amount of steel debris, mercury, titanium, and additional aluminum and silicates deposited on the coalescer.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fondeur, F.; Taylor-Pashow, K.
SRNL received two sets of SHT samples (MCU-14-667-672, pulled 8/27/2014 and MCU-14-846-847, pulled on 9/22/2014) for analysis. The samples were analyzed for composition. It is recommended that the solvent receives Isopar® L and TiDG trimming at this time. Analysis of sample MCU-14-846-847 indicates the solvent has evaporated Isopar®L and has lost TiDG to a level below the recommended minimum 1 mM level. Since the addition of MaxCalix to the SHT in early July 2014, the MaxCalix concentration in the solvent has reached nominal values. The laboratory will continue to monitor the quality of the solvent in particular for any newmore » impurity or degradation of the solvent components.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moyer, Bruce A; Bonnesen, Peter V; Delmau, Laetitia Helene
2011-01-01
This paper describes the chemical performance of the Next-Generation Caustic-Side Solvent Extraction (NG-CSSX) process in its current state of development for removal of cesium from the alkaline high-level tank wastes at the Savannah River Site (SRS) in the US Department of Energy (USDOE) complex. Overall, motivation for seeking a major enhancement in performance for the currently deployed CSSX process stems from needs for accelerating the cleanup schedule and reducing the cost of salt-waste disposition. The primary target of the NG-CSSX development campaign in the past year has been to formulate a solvent system and to design a corresponding flowsheet thatmore » boosts the performance of the SRS Modular CSSX Unit (MCU) from a current minimum decontamination factor of 12 to 40,000. The chemical approach entails use of a more soluble calixarene-crown ether, called MaxCalix, allowing the attainment of much higher cesium distribution ratios (DCs) on extraction. Concurrently decreasing the Cs-7SB modifier concentration is anticipated to promote better hydraulics. A new stripping chemistry has been devised using a vitrification-friendly aqueous boric acid strip solution and a guanidine suppressor in the solvent, resulting in sharply decreased DCs on stripping. Results are reported herein on solvent phase behavior and batch Cs distribution for waste simulants and real waste together with a preliminary flowsheet applicable for implementation in the MCU. The new solvent will enable MCU to process a much wider range of salt feeds and thereby extend its service lifetime beyond its design life of three years. Other potential benefits of NG-CSSX include increased throughput of the SRS Salt Waste Processing Facility (SWPF), currently under construction, and an alternative modular near-tank application at Hanford.« less
Sample Results From The Extraction, Scrub, And Strip Test For The Blended NGS Solvent
DOE Office of Scientific and Technical Information (OSTI.GOV)
Washington, A. L. II; Peters, T. B.
This report summarizes the results of the extraction, scrub, and strip testing for the September 2013 sampling of the Next Generation Solvent (NGS) Blended solvent from the Modular Caustic Side-Solvent Extraction Unit (MCU) Solvent Hold Tank. MCU is in the process of transitioning from the BOBCalixC6 solvent to the NGS Blend solvent. As part of that transition, MCU has intentionally created a blended solvent to be processed using the Salt Batch program. This sample represents the first sample received from that blended solvent. There were two ESS tests performed where NGS blended solvent performance was assessed using either the Tankmore » 21 material utilized in the Salt Batch 7 analyses or a simulant waste material used in the V-5/V-10 contactor testing. This report tabulates the temperature corrected cesium distribution, or D Cs values, step recovery percentage, and actual temperatures recorded during the experiment. This report also identifies the sample receipt date, preparation method, and analysis performed in the accumulation of the listed values. The calculated extraction D Cs values using the Tank 21H material and simulant are 59.4 and 53.8, respectively. The DCs values for two scrub and three strip processes for the Tank 21 material are 4.58, 2.91, 0.00184, 0.0252, and 0.00575, respectively. The D-values for two scrub and three strip processes for the simulant are 3.47, 2.18, 0.00468, 0.00057, and 0.00572, respectively. These values are similar to previous measurements of Salt Batch 7 feed with lab-prepared blended solvent. These numbers are considered compatible to allow simulant testing to be completed in place of actual waste due to the limited availability of feed material.« less
Wing flexibility improves bumblebee flight stability.
Mistick, Emily A; Mountcastle, Andrew M; Combes, Stacey A
2016-11-01
Insect wings do not contain intrinsic musculature to change shape, but rather bend and twist passively during flight. Some insect wings feature flexible joints along their veins that contain patches of resilin, a rubber-like protein. Bumblebee wings exhibit a central resilin joint (1m-cu) that has previously been shown to improve vertical force production during hovering flight. In this study, we artificially stiffened bumblebee (Bombus impatiens) wings in vivo by applying a micro-splint to the 1m-cu joint, and measured the consequences for body stability during forward flight in both laminar and turbulent airflow. In laminar flow, bees with stiffened wings exhibited significantly higher mean rotation rates and standard deviation of orientation about the roll axis. Decreasing the wing's flexibility significantly increased its projected surface area relative to the oncoming airflow, likely increasing the drag force it experienced during particular phases of the wing stroke. We hypothesize that higher drag forces on stiffened wings decrease body stability when the left and right wings encounter different flow conditions. Wing splinting also led to a small increase in body rotation rates in turbulent airflow, but this change was not statistically significant, possibly because bees with stiffened wings changed their flight behavior in turbulent flow. Overall, we found that wing flexibility improves flight stability in bumblebees, adding to the growing appreciation that wing flexibility is not merely an inevitable liability in flapping flight, but can enhance flight performance. © 2016. Published by The Company of Biologists Ltd.
Design of the intelligent smoke alarm system based on photoelectric smoke
NASA Astrophysics Data System (ADS)
Ma, Jiangfei; Yang, Xiufang; Wang, Peipei
2017-02-01
This paper designed a kind of intelligent smoke alarm system based on photoelectric smoke detector and temperature, The system takes AT89C51 MCU as the core of hardware control and Labview as the host computer monitoring center.The sensor system acquires temperature signals and smoke signals, the MCU control A/D by Sampling and converting the output analog signals , and then the two signals will be uploaded to the host computer through the serial communication. To achieve real-time monitoring of smoke and temperature in the environment, LabVIEW monitoring platform need to hold, process, analysis and display these samping signals. The intelligent smoke alarm system is suitable for large scale shopping malls and other public places, which can greatly reduce the false alarm rate of fire, The experimental results show that the system runs well and can alarm when the setting threshold is reached,and the threshold parameters can be adjusted according to the actual conditions of the field. The system is easy to operate, simple in structure, intelligent, low cost, and with strong practical value.
NASA Astrophysics Data System (ADS)
Yusha, V. L.; Chernov, G. I.; Kalashnikov, A. M.
2017-08-01
The paper examines the mobile compressor unit (MCU) heat losses recovery system waste heat exchanger prototype external thermal insulation types influence on the operational efficiency. The study is conducted by means of the numerical method through the modellingof the heat exchange processes carried out in the waste heat exchanger in ANSUS. Thermaflex, mineral wool, penofol, water and air were applied as the heat exchanger external insulation. The study results showed the waste heat exchanger external thermal insulationexistence or absence to have a significant impact on the heat exchanger operational efficiency.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fondeur, F. F.
The Office of Waste Processing, within the Office of Technology Innovation and Development, funded the development of an enhanced Caustic-Side Solvent Extraction (CSSX) solvent for deployment at the Savannah River Site for removal of cesium from High Level Waste. This effort lead to the development of the Next Generation Solvent (NGS) with Tris (3,7-dimethyl octyl) guanidine (TiDG). The first deployment target for the NGS solvent is within the Modular CSSX Unit (MCU). Deployment of a new chemical within an existing facility requires verification that the new chemical components are compatible with the installed equipment. In the instance of a newmore » organic solvent, the primary focus is on compatibility of the solvent with organic polymers used in the affected facility. This report provides the calculated data from exposing these polymers to the Next Generation Solvent. An assessment of the dimensional stability of polymers known to be used or present in the MCU, Defense Waste Processing Facility (DWPF), and Saltstone facilities that will be exposed to the NGS showed that TiDG could selectively affect the elastomers and some thermoplastics to varying extents, but the typical use of these polymers in a confined geometry will likely prevent the NGS from impacting component performance. The polymers identified as of primary concern include Grafoil® (flexible graphite), Tefzel®, Isolast®, ethylene-propylene-diene monomer (EPDM) rubber, nitrile-butadiene rubber (NBR), styrene-butadiene rubber (SBR), ultra high molecular weight polyethylene (UHMWPE), and fluorocarbon rubber (FKM). Certain polymers like NBR and EPDM were found to interact mildly with NGS but their calculated swelling and the confined geometry will impede interaction with NGS. In addition, it was found that Vellumoid (cellulose fibers-reinforced glycerin and protein) may leach protein and Polyvinyl Chloride (PVC) may leach plasticizer (such as Bis-Ethylhexyl-Phthalates) into the NGS solvent. Either case will not impact decontamination or immobilization operations at Savannah River Site (SRS). Some applications have zero tolerance for dimensional changes such as the operation of valves while other applications a finite dimensional change improves the function of the application such as seals and gaskets. Additional considerations are required before using the conclusions from this work to judge outcomes in field applications. Decane, a component of Isopar L that is most likely to interact with the polymers, mildly interacted with the elastomers and the propylene based polymers but their degree of swelling is at most 10% and the confined geometry that they are typically placed in indicate this is not significant. In addition, it was found that Vellumoid may leach protein into the NGS solvent. Since Vellumoid is used at the mixer in Saltstone where it sees minimum quantities of solvent, this leaching has no effect on the extraction process at MCU or the immobilization process at saltstone. No significant interaction is expected between MaxCalix and the polymers and elastomers used at MCU, DWPF, and Saltstone. Overall, minimal and insignificant interactions are expected on extraction and immobilization operations when MCU switches from CSSX to NGS solvent. It is expected that contacting NGS will not accelerate the aging rate of polymers and elastomers under radiation and heat. This is due to the minimal interaction between NGS and the polymers and the confined geometries for these polymers. SRNL recommends the use of the HSP method (for screening) and some testing to evaluate the impact of other organic such as alcohols, glycolate, and their byproducts on the polymers used throughout the site.« less
Verma, Manish; Callio, Jason; Otero, P Anthony; Sekler, Israel; Wills, Zachary P; Chu, Charleen T
2017-11-15
Mutations in leucine-rich repeat kinase 2 (LRRK2) contribute to development of late-onset familial Parkinson's disease (PD), with clinical features of motor and cognitive dysfunction indistinguishable from sporadic PD. Calcium dysregulation plays an important role in PD pathogenesis, but the mechanisms of neurodegeneration remain unclear. Recent reports indicate enhanced excitatory neurotransmission in cortical neurons expressing mutant LRRK2, which occurs before the well-characterized phenotype of dendritic shortening. As mitochondria play a major role in the rapid buffering of cytosolic calcium, we hypothesized that altered mitochondrial calcium handling contributes to dendritic retraction elicited by the LRRK2-G2019S and -R1441C mutations. In primary mouse cortical neurons, we observed increased depolarization-induced mitochondrial calcium uptake. We found that expression of mutant LRRK2 elicited transcriptional upregulation of the mitochondrial calcium uniporter (MCU) and the mitochondrial calcium uptake 1 protein (MICU1) with no change in levels of the mitochondrial calcium antiporter NCLX. Elevated MCU and MICU1 were also observed in LRRK2-mutated patient fibroblasts, along with increased mitochondrial calcium uptake, and in postmortem brains of sporadic PD/PDD patients of both sexes. Transcriptional upregulation of MCU and MICU1 was caused by activation of the ERK1/2 (MAPK3/1) pathway. Inhibiting ERK1/2 conferred protection against mutant LRRK2-induced neurite shortening. Pharmacological inhibitors or RNAi knockdown of MCU attenuated mitochondrial calcium uptake and dendritic/neuritic shortening elicited by mutant LRRK2, whereas expression of a constitutively active mutant of NCLX that enhances calcium export from mitochondria was neuroprotective. These data suggest that an increased susceptibility to mitochondrial calcium dysregulation contributes to dendritic injury in mutant LRRK2 pathogenesis. SIGNIFICANCE STATEMENT Cognitive dysfunction and dementia are common features of Parkinson's disease (PD), causing significant disability. Mutations in LRRK2 represent the most common known genetic cause of PD. We found that PD-linked LRRK2 mutations increased dendritic and mitochondrial calcium uptake in cortical neurons and familial PD patient fibroblasts, accompanied by increased expression of the mitochondrial calcium transporter MCU. Blocking the ERK1/2-dependent upregulation of MCU conferred protection against mutant LRRK2-elicited dendrite shortening, as did inhibiting MCU-mediated calcium import. Conversely, stimulating the export of calcium from mitochondria was also neuroprotective. These results implicate increased susceptibility to mitochondrial calcium overload in LRRK2-driven neurodegeneration, and suggest possible interventions that may slow the progression of cognitive dysfunction in PD. Copyright © 2017 the authors 0270-6474/17/3711152-15$15.00/0.
Medvedeva, Yuliya V.; Weiss, John H.
2014-01-01
Ca2+ and Zn2+ have both been implicated in the induction of acute ischemic neurodegeneration. We recently examined changes in intracellular Zn2+ and Ca2+ in CA1 pyramidal neurons subjected to oxygen glucose deprivation (OGD), and found that Zn2+ rises precede and contribute to the onset of terminal Ca2+ rises (“Ca2+ deregulation”), which are causatively linked to a lethal loss of membrane integrity. The present study seeks to examine the specific role of intramitochondrial Zn2+ accumulation in ischemic injury, using blockers of the mitochondrial Ca2+ uniporter (MCU), through which both Zn2+ and Ca2+ appear able to enter the mitochondrial matrix. In physiological extracellular Ca2+, treatment with the MCU blocker, Ruthenium Red (RR), accelerated the Ca2+ deregulation, most likely by disrupting mitochondrial Ca2+ buffering and thus accelerating the lethal cytosolic Ca2+ overload. However, when intracellular Ca2+ overload was slowed, either by adding blockers of major Ca2+ entry channels or by lowering the concentration of Ca2+ in the extracellular buffer, Ca2+ deregulation was delayed, and under these conditions either Zn2+ chelation or MCU blockade resulted in similar further delays of the Ca2+ deregulation. In parallel studies using the reactive oxygen species (ROS) indicator, hydroethidine, lowering Ca2+ surprisingly accelerated OGD induced ROS generation, and in these low Ca2+ conditions, either Zn2+ chelation or MCU block slowed the ROS generation. These studies suggest that, during acute ischemia, Zn2+ entry into mitochondria via the MCU induces mitochondrial dysfunction (including ROS generation) that occurs upstream of, and contributes to the terminal Ca2+ deregulation. PMID:24787898
Zampieri, Sandra; Mammucari, Cristina; Romanello, Vanina; Barberi, Laura; Pietrangelo, Laura; Fusella, Aurora; Mosole, Simone; Gherardi, Gaia; Höfer, Christian; Löfler, Stefan; Sarabon, Nejc; Cvecka, Jan; Krenn, Matthias; Carraro, Ugo; Kern, Helmut; Protasi, Feliciano; Musarò, Antonio; Sandri, Marco; Rizzuto, Rosario
2016-12-01
Age-related sarcopenia is characterized by a progressive loss of muscle mass with decline in specific force, having dramatic consequences on mobility and quality of life in seniors. The etiology of sarcopenia is multifactorial and underlying mechanisms are currently not fully elucidated. Physical exercise is known to have beneficial effects on muscle trophism and force production. Alterations of mitochondrial Ca 2+ homeostasis regulated by mitochondrial calcium uniporter (MCU) have been recently shown to affect muscle trophism in vivo in mice. To understand the relevance of MCU-dependent mitochondrial Ca 2+ uptake in aging and to investigate the effect of physical exercise on MCU expression and mitochondria dynamics, we analyzed skeletal muscle biopsies from 70-year-old subjects 9 weeks trained with either neuromuscular electrical stimulation (ES) or leg press. Here, we demonstrate that improved muscle function and structure induced by both trainings are linked to increased protein levels of MCU Ultrastructural analyses by electron microscopy showed remodeling of mitochondrial apparatus in ES-trained muscles that is consistent with an adaptation to physical exercise, a response likely mediated by an increased expression of mitochondrial fusion protein OPA1. Altogether these results indicate that the ES-dependent physiological effects on skeletal muscle size and force are associated with changes in mitochondrial-related proteins involved in Ca 2+ homeostasis and mitochondrial shape. These original findings in aging human skeletal muscle confirm the data obtained in mice and propose MCU and mitochondria-related proteins as potential pharmacological targets to counteract age-related muscle loss. © 2016 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.
Solvent Hold Tank Sample Results for MCU-15-661-662-663: April 2015 Monthly Sample
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fondeur, F.; Taylor-Pashow, K.
2015-07-08
The Savannah River National Lab (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-15-661, MCU-15-662, and MCU-15-663 pulled on April 2, 2015) for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-15-661-662-663 indicated a low concentration (~ 63% of nominal) of the suppressor (TiDG) and a slightly below the nominal concentration (~ 10% below nominal) of the extractant (MaxCalix). The modifier (CS-7SB) level was also 10% below its nominal value while the Isopar™ L level was slightly above its nominal value. This analysis confirms the addition of Isopar™L to the solvent onmore » March 6, 2015. Despite that the values are below target component levels, the current levels of TiDG, CS-7SB and MaxCalix are sufficient for continuing operation without adding a trim at this time until the next monthly sample. No impurities above the 1000 ppm level were found in this solvent. However, the sample was found to contain approximately 18.4 ug/g solvent mercury. The gamma level increased to 8 E5 dpm/mL solvent and it represents an order of magnitude increase relative to previous solvent samples. The increase means less cesium is being stripped from the solvent. Further analysis is needed to determine if the recent spike in the gamma measurement is due to external factors such as algae or other material that may impede stripping. The laboratory will continue to monitor the quality of the solvent in particular for any new impurity or degradation of the solvent components.« less
Analysis of an MCU HEPA filter
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, T. B.; Fondeur, F. F.
A series of direct analyses on three portions (inlet, center, and outlet) of the High Efficiency Particulate Air (HEPA) filter material from the Modular Caustic-Side Solvent Extraction Unit (MCU) have been performed; this includes x-ray methods such as X-Ray Diffraction (XRD), Contained Scanning Electron Microscopy (CSEM) and X-Ray Fluorescence (XRF), as well as Fourier Transform InfraRed spectroscopy (FTIR). Additionally, two leaching studies (one with water, one with dichloromethane) have been performed on three portions (inlet, center, and outlet) of the HEPA filter material, with the leachates being analyzed by Inductively-coupled plasma emission spectroscopy (ICPES), Semi-Volatile Organic Analysis (SVOA) and gammascan.more » From the results of the analyses, SRNL feels that cesium-depleted solvent is being introduced into the HEPA filter. The most likely avenue for this is mechanical aerosolization of solvent, where the aerosol is then carried along an airstream into the HEPA filter. Once introduced into the HEPA filter media, the solvent wicks throughout the material, and migrates towards the outlet end. Once on the outlet end, continual drying could cause particulate flakes to exit the filter and travel farther down the airstream path.« less
Solvent hold tank sample results for MCU-16-1317-1318-1319. September 2016 monthly sample
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fondeur, F. F.; Jones, D. H.
2017-01-01
Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-16-1317-1318-1319), pulled on 09/12/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-1317-1318-1319 indicated the Isopar™L concentration is above its nominal level (102%). The extractant (MaxCalix) and the modifier (CS-7SB) are 5% and 10 % below their nominal concentrations. The suppressor (TiDG) is 77% below its nominal concentration. A summary of the concentration of the relevant solvent components is shown below. This analysis confirms the Isopar™ addition to the solvent in August. This analysis also indicates the solvent maymore » require the addition of TiDG, and possibly of modifier to restore them to nominal levels.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poirier, M.; Burket, P.
The Savannah River Site (SRS) is currently treating radioactive liquid waste with the Actinide Removal Process (ARP) and the Modular Caustic Side Solvent Extraction Unit (MCU). Recently, the low filter flux through the ARP of approximately 5 gallons per minute has limited the rate at which radioactive liquid waste can be treated. Salt Batch 6 had a lower processing rate and required frequent filter cleaning. Savannah River Remediation (SRR) has a desire to understand the causes of the low filter flux and to increase ARP/MCU throughput. SRR requested SRNL to conduct bench-scale filter tests to evaluate whether sodium oxalate, sodiummore » aluminosilicate, or aluminum solids (i.e., gibbsite and boehmite) could be the cause of excessive fouling of the crossflow or secondary filter at ARP. The authors conducted the tests by preparing slurries containing 6.6 M sodium Salt Batch 6 supernate, 2.5 g MST/L slurry, and varying concentrations of sodium oxalate, sodium aluminosilicate, and aluminum solids, processing the slurry through a bench-scale filter unit that contains a crossflow primary filter and a dead-end secondary filter, and measuring filter flux and transmembrane pressure as a function of time. Among the conclusions drwn from this work are the following: (1) All of the tests showed some evidence of fouling the secondary filter. This fouling could be from fine particles passing through the crossflow filter. (2) The sodium oxalate-containing feeds behaved differently from the sodium aluminosilicate- and gibbsite/boehmite-containing feeds.« less
A Standard-Compliant Virtual Meeting System with Active Video Object Tracking
NASA Astrophysics Data System (ADS)
Lin, Chia-Wen; Chang, Yao-Jen; Wang, Chih-Ming; Chen, Yung-Chang; Sun, Ming-Ting
2002-12-01
This paper presents an H.323 standard compliant virtual video conferencing system. The proposed system not only serves as a multipoint control unit (MCU) for multipoint connection but also provides a gateway function between the H.323 LAN (local-area network) and the H.324 WAN (wide-area network) users. The proposed virtual video conferencing system provides user-friendly object compositing and manipulation features including 2D video object scaling, repositioning, rotation, and dynamic bit-allocation in a 3D virtual environment. A reliable, and accurate scheme based on background image mosaics is proposed for real-time extracting and tracking foreground video objects from the video captured with an active camera. Chroma-key insertion is used to facilitate video objects extraction and manipulation. We have implemented a prototype of the virtual conference system with an integrated graphical user interface to demonstrate the feasibility of the proposed methods.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fondeur, F.; Taylor-Pashow, K.
Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-15-556, MCU-15-557, and MCU-15-558), pulled on 03/16/2015 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-15-556-557-558 indicated a low concentration (~ 78 % of nominal) of the suppressor (TiDG) and concentrations of the extractant (MaxCalix), and of the modifier (CS-7SB) in the solvent that were slightly lower than nominal. This analysis confirms the addition of TiDG, MaxCalix, and modifier to the solvent in February 2015. Based on the current monthly sample, the levels of TiDG, MaxCalix, and modifier aremore » sufficient for continuing operation without adding a trim at this time. No impurities above the 1000 ppm level were found in this solvent by the Semi-Volatile Organic Analysis (SVOA). However, the p-nut vials that delivered the samples contained small (1 mm) droplets of oxidized modifier and amides (as detected by the FTIR analysis). In addition, up to 21 microgram of mercury per gram of solvent (or 17.4 µg/mL) was detected in this sample. The laboratory will continue to monitor the quality of the solvent in particular for any new impurities or degradation of the solvent components.« less
He, Li; Huang, G H; Lu, Hongwei
2011-10-15
Recent studies indicated that municipal solid waste (MSW) is a major contributor to global warming due to extensive emissions of greenhouse gases (GHGs). However, most of them focused on investigating impacts of MSW on GHG emission amounts. This study presents two mixed integer bilevel decision-making models for integrated municipal solid waste management and GHG emissions control: MGU-MCL and MCU-MGL. The MGU-MCL model represents a top-down decision process, with the environmental sectors at the national level dominating the upper-level objective and the waste management sectors at the municipal level providing the lower-level objective. The MCU-MGL model implies a bottom-up decision process where municipality plays a leading role. Results from the models indicate that: the top-down decisions would reduce metric tonne carbon emissions (MTCEs) by about 59% yet increase about 8% of the total management cost; the bottom-up decisions would reduce MTCE emissions by about 13% but increase the total management cost very slightly; on-site monitoring and downscaled laboratory experiments are still required for reducing uncertainty in GHG emission rate from the landfill facility. Copyright © 2011 Elsevier B.V. All rights reserved.
Solvent Hold Tank Sample Results for MCU-16-596-597-598: April 2016 Monthly Sample
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fondeur, F. F.; Jones, D. H.
2016-07-12
Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-16-596-597-598), pulled on 04/30/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-596-597-598 indicated the Isopar™L concentration is above its nominal level (102%). The modifier (CS-7SB) is 14% below its nominal concentration, while the TiDG and MaxCalix concentrations are at and above their nominal concentrations, respectively. This analysis confirms the solvent may require the addition of modifier. Based on the current monthly sample, the levels of TiDG, Isopar™L, MaxCalix, and modifier are sufficient for continuing operation but are expectedmore » to decrease with time. Periodic characterization and trimming additions to the solvent are recommended.« less
Research on mechanical properties of silver-bearing antibacterial duplex stainless steel
NASA Astrophysics Data System (ADS)
Liu, Dong; Xiang, Hongliang
2017-04-01
In this paper, silver-bearing antibacterial duplex stainless steels were prepared by adding Ag or Cu-Ag alloy particles. The microstructure, mechanical properties and fracture morphology were investigated in detail by OM, ESEM and tensile testing machine. Tensile tests indicate that the tensile fractures of Ag-bearing antibacterial duplex stainless steel and CD4MCu have the typical ductile character and toughening nests are isometric. After the solution treatment at 1050 ℃, for the material prepared by adding 150-300 µm Cu-Ag master alloy after the solution treatment at 1050 ℃, its plasticity is superior to that of CD4MCu, the strength and hardness are equivalent. But for the material prepared by adding pure Ag alloy particles, its plasticity, strength and hardness are less than that of CD4MCu. When the solution temperature rises, the plastic, strength and hardness of the material prepared by adding 150-300 µm Cu-Ag decrease.
Calculation evaluation of multiplying properties of LWR with thorium fuel
NASA Astrophysics Data System (ADS)
Shamanin, I. V.; Grachev, V. M.; Knyshev, V. V.; Bedenko, S. V.; Novikova, N. G.
2017-01-01
The results of multiplying properties design research of the unit cell and LWR fuel assembly with the high temperature gas-cooled thorium reactor fuel pellet are presented in the work. The calculation evaluation showed the possibility of using thorium in LWR effectively. In this case the amount of fissile isotope is 2.45 times smaller in comparison with the standard loading of LWR. The research and numerical experiments were carried out using the verified accounting code of the program MCU5, modern libraries of evaluated nuclear data and multigroup approximations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fondeur, F. F.; Jones, D. H.
A trend summary of three Solvent Hold Tank (SHT) monthly samples; MCU-16-1488-1493 (December 2016), MCU-17-86-88 (January 2017), and MCU-17-119-121 (February 2017) are reported. Analyses indicate that the modifier (CS-7SB) and the extractant (MaxCalix) concentrations are at their nominal recommended levels (169,000 mg/L and 46,300 mg/L respectively). The suppressor (TiDG) level has decreased to a steady state level of 673 mg/L well above the minimum recommended level (479 mg/L). This analysis confirms the Isopar™ addition to the solvent in January 18, 2017. This analysis also indicates the solvent did not require further additions. Based on the current monthly sample, the levelsmore » of TiDG, Isopar™L, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterization and trimming additions to the solvent are recommended. No impurities above the 1000 ppm level were found in this solvent by the Semi-Volatile Organic Analysis (SVOA). No impurities were observed in the Hydrogen Nuclear Magnetic Resonance (HNMR). Another impurity observed in the samples was mercury. Up to 38 ± 8 micrograms of mercury per mL of solvent was detected in these samples (the average of the CV-AA and XRF methods). The higher mercury concentration in the solvent (as determined in the last three monthly samples) is possibly due to the higher mercury concentration in Salt Batches 8 and 9 (Tank 49H) or mixing of previously undisturbed areas of high mercury concentration in Tank 49H. The gamma level (0.21E5 dpm/mL) measured in the February SHT sample was one order of magnitude lower than the gamma levels observed in the December and January SHT samples. The February gamma level is consistent with the solvent being idle (since January 10, 2017). The gamma levels observed in the December and January SHT samples were consistent with previous monthly measurements where the process operated normally. The laboratory will continue to monitor the quality of the solvent in particular for any new impurities or degradation of the solvent components.« less
PRELIMINARY EVALUATION OF DWPF IMPACTS OF BORIC ACID USE IN CESIUM STRIP FOR SWPF AND MCU
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stone, M.
2010-09-28
A new solvent system is being evaluated for use in the Modular Caustic-Side Solvent Extraction Unit (MCU) and in the Salt Waste Processing Facility (SWPF). The new system includes the option to replace the current dilute nitric acid strip solution with boric acid. To support this effort, the impact of using 0.01M, 0.1M, 0.25M and 0.5M boric acid in place of 0.001M nitric acid was evaluated for impacts on the DWPF facility. The evaluation only covered the impacts of boric acid in the strip effluent and does not address the other changes in solvents (i.e., the new extractant, called MaxCalix,more » or the new suppressor, guanidine). Boric acid additions may lead to increased hydrogen generation during the SRAT and SME cycles as well as change the rheological properties of the feed. The boron in the strip effluent will impact glass composition and could require each SME batch to be trimmed with boric acid to account for any changes in the boron from strip effluent additions. Addition of boron with the strip effluent will require changes in the frit composition and could lead to changes in melt behavior. The severity of the impacts from the boric acid additions is dependent on the amount of boric acid added by the strip effluent. The use of 0.1M or higher concentrations of boric acid in the strip effluent was found to significantly impact DWPF operations while the impact of 0.01M boric acid is expected to be relatively minor. Experimental testing is required to resolve the issues identified during the preliminary evaluation. The issues to be addressed by the testing are: (1) Impact on SRAT acid addition and hydrogen generation; (2) Impact on melter feed rheology; (3) Impact on glass composition control; (4) Impact on frit production; and (5) Impact on melter offgas. A new solvent system is being evaluated for use in the Modular Caustic-Side Solvent Extraction Unit (MCU) and in the Salt Waste Processing Facility (SWPF). The new system includes the option to replace the current dilute nitric acid strip solution with boric acid. To support this effort, the impact of using 0.01M, 0.1M, 0.25M and 0.5M boric acid in place of 0.001M nitric acid was evaluated for impacts on the DWPF facility. The evaluation only covered the impacts of boric acid in the strip effluent and does not address the other changes in solvents (i.e., the new extractant, called MaxCalix, or the new suppressor, guanidine). Experimental testing with the improved solvent is required to determine the impact of any changes in the entrained solvent on DWPF processing.« less
Analog design of wireless control for home equipment
NASA Astrophysics Data System (ADS)
Zheng, Shiyong; Li, Zhao; Li, Biqing; Jiang, Suping
2018-04-01
This design consists of a STC89C52 microcontroller, a serial Bluetooth module and the Android system. Production of STC89C52 controlled by single-chip computer telephone systems. The system is composed of mobile phone Android system as a master in the family centre,via serial Bluetooth module pass instructions and information to implement wireless transceiver using STC89C52 MCU wireless Bluetooth transmission to control homedevices. System high reliability, low cost easy to use, stong applicability and other characerristics, can be used in single-user family, has great significance.
Sample Results from MCU Solids Outage
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, T.; Washington, A.; Oji, L.
2014-09-22
Savannah River National Laboratory (SRNL) has received several solid and liquid samples from MCU in an effort to understand and recover from the system outage starting on April 6, 2014. SRNL concludes that the presence of solids in the Salt Solution Feed Tank (SSFT) is the likely root cause for the outage, based upon the following discoveries: A solids sample from the extraction contactor #1 proved to be mostly sodium oxalate; A solids sample from the scrub contactor#1 proved to be mostly sodium oxalate; A solids sample from the Salt Solution Feed Tank (SSFT) proved to be mostly sodium oxalate;more » An archived sample from Tank 49H taken last year was shown to contain a fine precipitate of sodium oxalate; A solids sample from ; A liquid sample from the SSFT was shown to have elevated levels of oxalate anion compared to the expected concentration in the feed. Visual inspection of the SSFT indicated the presence of precipitated or transferred solids, which were likely also in the Salt Solution Receipt Tank (SSRT). The presence of the solids coupled with agitation performed to maintain feed temperature resulted in oxalate solids migration through the MCU system and caused hydraulic issues that resulted in unplanned phase carryover from the extraction into the scrub, and ultimately the strip contactors. Not only did this carryover result in the Strip Effluent (SE) being pushed out of waste acceptance specification, but it resulted in the deposition of solids into several of the contactors. At the same time, extensive deposits of aluminosilicates were found in the drain tube in the extraction contactor #1. However it is not known at this time how the aluminosilicate solids are related to the oxalate solids. The solids were successfully cleaned out of the MCU system. However, future consideration must be given to the exclusion of oxalate solids into the MCU system. There were 53 recommendations for improving operations recently identified. Some additional considerations or additional details are provided below as recommendations. From this point on, IC-Anions analyses of the DSSHT should be part of the monthly routine analysis in order to spot negative trends in the oxalate leaving the MCU system. Care must be taken to monitor the oxalate content to watch for sudden precipitation of oxalate salts in the system; Conduct a study to optimize the cleaning strategy at ARP-MCU through decreasing the concentration or entirely eliminating the oxalic acid; The contents of the SSFT should remain unagitated. Routine visual observation should be maintained to ensure there is not a large buildup of solids. As water with agitation provided sufficient removal of the solids in the feed tank, it should be considered as a good means for dissolving oxalate solids if they are found in the future; Conduct a study to improve prediction of oxalate solubility in salt batch feed materials. As titanium and mercury have been found in various solids in this report, evaluate if either element plays a role in oxalate solubility during processing; Salt batch characterization focuses primarily on characterization and testing of unaltered Tank 21H material; however, non-typical feeds are developed through cleaning, washing, and/or sump transfers. As these solutions are processed through MCU, they may precipitate solids or reduce performance. Salt batch characterization and testing should be expanded to encompass a broader range of feeds that may be processed through ARPMCU.« less
Impacts of P-f & Q-V Droop Control on MicroGrids Transient Stability
NASA Astrophysics Data System (ADS)
Zhao-xia, Xiao; Hong-wei, Fang
Impacts of P-f & Q-V droop control on MicroGrid transient stability was investigated with a wind unit of asynchronous generator in the MicroGrid. The system frequency stability was explored when the motor load starts and its load power changes, and faults of different types and different locations occurs. The simulations were done by PSCAD/EMTDC.
Zhu, Chengzhou; Shi, Qiurong; Fu, Shaofang; Song, Junhua; Xia, Haibing; Du, Dan; Lin, Yuehe
2016-10-01
To accelerate hydrogel formation and further simplify the synthetic procedure, a series of MCu (M = Pd, Pt, and Au) bimetallic aerogels is synthesized from the in situ reduction of metal precursors through enhancement of the gelation kinetics at elevated temperature. Moreover, the resultant PdCu aerogel with ultrathin nanowire networks exhibits excellent electrocatalytic performance toward ethanol oxidation, holding promise in fuel-cell applications. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Prahara, E.; Prasetya, R. A.
2018-01-01
In many developing countries, transportation modes are more varied than the other country. For example, in Jakarta, Indonesia, in some roadway, motorcycle is the most dominant vehicle, with total volume is four times higher than a passenger car. Thus, the traffic characteristic in motorcycle-dominated traffic differs from a common traffic situation. The purpose of this study is to apply the concept and theory developed to analyze motorcycle behaviour under motorcycle-dominated traffic condition. The survey is applied by recording the traffic flow movement of research location at specified time period. The macroscopic characteristic analyzed in this research is a speed-flow relationship based on motorcycle equivalent unit (MCU). Furthermore, a detail microscopic characteristic analyzed that is motorcycle time headway regarding traffic flow. MCU values computed were consists of motorcycle (MC), light vehicle (LV) and heavy vehicle (HV). Those values were calculated 1.00, 6.13 and 10.71 respectively. The speed and volume relationship result is showing a linear regression model with R2 value is 0.58, it can be explained that the correlation between two variables is intermediate. The headway distribution of motorcycle is compatible with the negative exponential distribution which fitted with the proposed theory for a small vehicle such as a motorcycle.
Neutron radiation characteristics of the IVth generation reactor spent fuel
NASA Astrophysics Data System (ADS)
Bedenko, Sergey; Shamanin, Igor; Grachev, Victor; Knyshev, Vladimir; Ukrainets, Olesya; Zorkin, Andrey
2018-03-01
Exploitation of nuclear power plants as well as construction of new generation reactors lead to great accumulation of spent fuel in interim storage facilities at nuclear power plants, and in spent fuel «wet» and «dry» long-term storages. Consequently, handling the fuel needs more attention. The paper is focused on the creation of an efficient computational model used for developing the procedures and regulations of spent nuclear fuel handling in nuclear fuel cycle of the new generation reactor. A Thorium High-temperature Gas-Cooled Reactor Unit (HGTRU, Russia) was used as an object for numerical research. Fuel isotopic composition of HGTRU was calculated using the verified code of the MCU-5 program. The analysis of alpha emitters and neutron radiation sources was made. The neutron yield resulting from (α,n)-reactions and at spontaneous fission was calculated. In this work it has been shown that contribution of (α,n)-neutrons is insignificant in case of such (Th,Pu)-fuel composition and HGTRU operation mode, and integral neutron yield can be approximated by the Watt spectral function. Spectral and standardized neutron distributions were achieved by approximation of the list of high-precision nuclear data. The distribution functions were prepared in group and continuous form for further use in calculations according to MNCP, MCU, and SCALE.
A graphite oxide (GO)-based remote readable tamper evident seal
Cattaneo, Alessandro; Bossert, Jason Andrew; Guzman, Christian; ...
2016-09-08
Here, this paper presents a prototype of a remotely readable graphite oxide (GO) paper-based tamper evident seal. The proposed device combines the tunable electrical properties offered by reduced graphite oxide (RGO) with a compressive sampling scheme. The benefit of using RGO as a tamper evident seal material is the sensitivity of its electrical properties to the common mechanisms adopted to defeat tamper-evident seals. RGO’s electrical properties vary upon local stress or cracks induced by mechanical action (e.g., produced by shimming or lifting attacks). Further, modification of the seal’s electrical properties can result from the incidence of other defeat mechanisms, suchmore » as temperature changes, solvent treatment and steam application. The electrical tunability of RGO enables the engraving of a circuit on the area of the tamper evident seal intended to be exposed to malicious attacks. The operation of the tamper evident seal, as well as its remote communication functionality, is supervised by a microcontroller unit (MCU). The MCU uses the RGO-engraved circuitry to physically implement a compressive sampling acquisition procedure. The compressive sampling scheme provides the seal with self-authentication and self-state-of-health awareness capabilities. Finally, the prototype shows potential for use in low-power, embedded, remote-operation nonproliferation security related applications.« less
The Mitochondrial Calcium Uniporter: Mice can live and die without it
Harrington, Josephine L; Murphy, Elizabeth
2014-01-01
Calcium is of critical importance to mitochondrial and cell function, and calcium signaling is highly localized in the cell. When stimulated, mitochondria are capable of rapidly taking up calcium, affecting both matrix energetics within mitochondria and shaping the amplitude and frequency of cytosolic calcium “waves”. During pathological conditions a large increase in mitochondrial calcium levels is thought to activate the mitochondrial permeability transition pore, resulting in cell death. The protein responsible for mitochondrial calcium uptake, the mitochondrial calcium uniporter (MCU), was identified in 2011 and its molecular elucidation has stimulated and invigorated research in this area. MCU knockout mice have been created, a variety of other regulators have been identified, and a disease phenotype in humans has been attributed to the loss of a uniporter regulator. In the three years since its molecular elucidation, further research into the MCU has revealed a complex uniporter, and raised many questions about its physiologic and pathologic cell roles. PMID:25451167
Dual functions of a small regulatory subunit in the mitochondrial calcium uniporter complex.
Tsai, Ming-Feng; Phillips, Charles B; Ranaghan, Matthew; Tsai, Chen-Wei; Wu, Yujiao; Willliams, Carole; Miller, Christopher
2016-04-21
Mitochondrial Ca(2+) uptake, a process crucial for bioenergetics and Ca(2+) signaling, is catalyzed by the mitochondrial calcium uniporter. The uniporter is a multi-subunit Ca(2+)-activated Ca(2+) channel, with the Ca(2+) pore formed by the MCU protein and Ca(2+)-dependent activation mediated by MICU subunits. Recently, a mitochondrial inner membrane protein EMRE was identified as a uniporter subunit absolutely required for Ca(2+) permeation. However, the molecular mechanism and regulatory purpose of EMRE remain largely unexplored. Here, we determine the transmembrane orientation of EMRE, and show that its known MCU-activating function is mediated by the interaction of transmembrane helices from both proteins. We also reveal a second function of EMRE: to maintain tight MICU regulation of the MCU pore, a role that requires EMRE to bind MICU1 using its conserved C-terminal polyaspartate tail. This dual functionality of EMRE ensures that all transport-competent uniporters are tightly regulated, responding appropriately to a dynamic intracellular Ca(2+) landscape.
Results Of Initial Analyses Of The Salt (Macro) Batch 9 Tank 21H Qualification Samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, T.
2015-10-08
Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Interim Salt Disposition Project (ISDP) Salt (Macro) Batch 9 for processing through the Actinide Removal Process (ARP) and the Modular Caustic-Side Solvent Extraction Unit (MCU). This document reports the initial results of the analyses of samples of Tank 21H. Analysis of the Tank 21H Salt (Macro) Batch 9 composite sample indicates that the material does not display any unusual characteristics. Further results on the chemistry and other tests will be issued in the future.
SR and mitochondria: calcium cross-talk between kissing cousins.
Dorn, Gerald W; Maack, Christoph
2013-02-01
The processes of excitation-contraction coupling in cardiac myocytes require enormous amounts of energy in the form of ATP, which is produced by oxidative phosphorylation in mitochondria. Due to the constantly varying workloads of the heart, efficient matching of energy supply to demand is a requisite for proper heart function. Ca(2+) is taken up by mitochondria via the mitochondrial Ca(2+) uniporter (MCU) where it stimulates key dehydrogenases of the Krebs cycle to match regeneration of NADH to its oxidation by the respiratory chain. The kinetics of mitochondrial Ca(2+) uptake, however, remain controversial due to the low Ca(2+) sensitivity of the MCU. Here, we review the evidence for the existence of a "mitochondrial Ca(2+) microdomain", in which the close association of the sarcoplasmic reticulum (SR) to mitochondria provides "hot spots" of very high Ca(2+) concentrations in the vicinity of mitochondria, sufficient to overcome the low Ca(2+) affinity of the MCU. Mitofusins 1 and 2 play redundant roles in regulating mitochondrial dynamics by controlling fusion of mitochondria with each other. Recent work revealed a unique role for mitofusin 2 in tethering mitochondria to the sarco-/endoplasmic reticulum in various cell types, including cardiac myocytes. Disruption of SR-mitochondrial Ca(2+) cross talk in heart failure through spatial and ionic alterations may give rise to energetic deficit and oxidative stress, two factors believed to play causal roles in the progression of the disease. On the other hand, excessive mitochondrial Ca(2+) uptake can trigger programmed necrosis, substantiating the ambiguity of the close interplay between these cousin organelles in health and disease. This article is part of a Special Issue entitled "Focus on Cardiac Metabolism". Copyright © 2012 Elsevier Ltd. All rights reserved.
Which is the best way of performing a Micturating Cystourethrogram in children?
Al-Imam, Ola Ali; Al-Nsour, Nareeman Moh'd; Al-Khulaifat, Samih
2008-01-01
The Micturating Cystourethrogram (MCU) is a tough and stressful examination for patients and their parents as well as the radiologists and pediatric radiology nurses. Even though, it is one of the most commonly used fluoroscopic procedures in pediatric radiology practice, there is no definite agreement as to the best way to perform it, considering that this examination results in the children receiving a high dose of radiation to the gonadal region. This review was undertaken to determine the best way to perform the MCU in modern pediatric radiology practice.
Heterometal silver/copper(I) modulated thermochromism of two isostructural iodoplumbates
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Honghong; Yu, Tanlai; An, Li
2015-01-15
Two isostructrual heterometallic iodoplumbates [Y(DMF){sub 8}]{sub 2n}[Pb{sub 7}M{sub 2}I{sub 22}]{sub n} [M=Cu(1), Ag(2)] have been prepared. Chargely balanced by [Y(DMF){sub 8}]{sup 3+}, [Pb{sub 7}M{sub 2}I{sub 22}]{sub n}{sup 6n−} displays a 1D zigzag chain constructed from MI{sub 4} tetrahedron and Pb{sub 7}I{sub 24} unit similar to a fragment of commonly observed (PbI{sub 3}){sub n}{sup n−} chain. Their band gaps (Eg) can be estimated as 2.66 and 2.72 eV, revealing potential semiconducting properties. Interestingly, thermochromism exhibits different response to the temperature for two compounds, which is verified by the diffuse-reflectance UV–visible spectra and crystallographic data at different temperatures. Moreover, this phenomenon ismore » attributed to the difference of heterometal Ag and Cu(I). - Graphical abstract: Two isostructrual heterometallic iodoplumbates [Y(DMF){sub 8}]{sub 2n}[Pb{sub 7}M{sub 2}I{sub 22}]{sub n} [M=Cu(1),Ag(2)] have been prepared. [Pb{sub 7}M{sub 2}I{sub 22}]{sub n}{sup 6n−} displays a 1D zigzag chain constructed from MI{sub 4} tetrahedron and Pb{sub 7}I{sub 24} unit similar to a fragment of commonly observed (PbI{sub 3}){sub n}{sup n−} chain. Interestingly, the thermochromism for two compounds exhibits different response to the temperature, which is attributed to the difference of heterometal Ag and Cu. - Highlights: • Two isostructrual heterometallic iodoplumbates have been prepared. • Single-crystal-X-ray diffraction data were collected at different temperatures. • Spectroscopic characterization showed semiconducting and thermochromic properties. • The difference of thermochromic properties for two compounds was studied.« less
Breen, P P; O'Keeffe, D T; Conway, R; Lyons, G M
2006-03-01
We describe the design of an intelligent drop foot stimulator unit for use in conjunction with a commercial neuromuscular electrical nerve stimulation (NMES) unit, the NT2000. The developed micro-controller unit interfaces to a personal computer (PC) and a graphical user interface (GUI) allows the clinician to graphically specify the shape of the stimulation intensity envelope required for a subject undergoing drop foot correction. The developed unit is based on the ADuC812S micro-controller evaluation board from Analog Devices and uses two force sensitive resistor (FSR) based foot-switches to control application of stimulus. The unit has the ability to display to the clinician how the stimulus intensity envelope is being delivered during walking using a data capture capability. The developed system has a built-in algorithm to dynamically adjust the delivery of stimulus to reflect changes both within the gait cycle and from cycle to cycle. Thus, adaptive control of stimulus intensity is achieved.
An Embedded Device for Real-Time Noninvasive Intracranial Pressure Estimation.
Matthews, Jonathan M; Fanelli, Andrea; Heldt, Thomas
2018-01-01
The monitoring of intracranial pressure (ICP) is indicated for diagnosing and guiding therapy in many neurological conditions. Current monitoring methods, however, are highly invasive, limiting their use to the most critically ill patients only. Our goal is to develop and test an embedded device that performs all necessary mathematical operations in real-time for noninvasive ICP (nICP) estimation based on a previously developed model-based approach that uses cerebral blood flow velocity (CBFV) and arterial blood pressure (ABP) waveforms. The nICP estimation algorithm along with the required preprocessing steps were implemented on an NXP LPC4337 microcontroller unit (MCU). A prototype device using the MCU was also developed, complete with display, recording functionality, and peripheral interfaces for ABP and CBFV monitoring hardware. The device produces an estimate of mean ICP once per minute and performs the necessary computations in 410 ms, on average. Real-time nICP estimates differed from the original batch-mode MATLAB implementation of theestimation algorithm by 0.63 mmHg (root-mean-square error). We have demonstrated that real-time nICP estimation is possible on a microprocessor platform, which offers the advantages of low cost, small size, and product modularity over a general-purpose computer. These attributes take a step toward the goal of real-time nICP estimation at the patient's bedside in a variety of clinical settings.
A Very Low Power MAC (VLPM) Protocol for Wireless Body Area Networks
Ullah, Niamat; Khan, Pervez; Kwak, Kyung Sup
2011-01-01
Wireless Body Area Networks (WBANs) consist of a limited number of battery operated nodes that are used to monitor the vital signs of a patient over long periods of time without restricting the patient’s movements. They are an easy and fast way to diagnose the patient’s status and to consult the doctor. Device as well as network lifetime are among the most important factors in a WBAN. Prolonging the lifetime of the WBAN strongly depends on controlling the energy consumption of sensor nodes. To achieve energy efficiency, low duty cycle MAC protocols are used, but for medical applications, especially in the case of pacemakers where data have time-limited relevance, these protocols increase latency which is highly undesirable and leads to system instability. In this paper, we propose a low power MAC protocol (VLPM) based on existing wakeup radio approaches which reduce energy consumption as well as improving the response time of a node. We categorize the traffic into uplink and downlink traffic. The nodes are equipped with both a low power wake-up transmitter and receiver. The low power wake-up receiver monitors the activity on channel all the time with a very low power and keeps the MCU (Micro Controller Unit) along with main radio in sleep mode. When a node [BN or BNC (BAN Coordinator)] wants to communicate with another node, it uses the low-power radio to send a wakeup packet, which will prompt the receiver to power up its primary radio to listen for the message that follows shortly. The wake-up packet contains the desired node’s ID along with some other information to let the targeted node to wake-up and take part in communication and let all other nodes to go to sleep mode quickly. The VLPM protocol is proposed for applications having low traffic conditions. For high traffic rates, optimization is needed. Analytical results show that the proposed protocol outperforms both synchronized and unsynchronized MAC protocols like T-MAC, SCP-MAC, B-MAC and X-MAC in terms of energy consumption and response time. PMID:22163818
NASA Astrophysics Data System (ADS)
Wei, Minsong; Xing, Fei; You, Zheng
2017-01-01
The advancing growth of micro- and nano-satellites requires miniaturized sun sensors which could be conveniently applied in the attitude determination subsystem. In this work, a profile detecting technology based high accurate wireless digital sun sensor was proposed, which could transform a two-dimensional image into two-linear profile output so that it can realize a high update rate under a very low power consumption. A multiple spots recovery approach with an asymmetric mask pattern design principle was introduced to fit the multiplexing image detector method for accuracy improvement of the sun sensor within a large Field of View (FOV). A FOV determination principle based on the concept of FOV region was also proposed to facilitate both sub-FOV analysis and the whole FOV determination. A RF MCU, together with solar cells, was utilized to achieve the wireless and self-powered functionality. The prototype of the sun sensor is approximately 10 times lower in size and weight compared with the conventional digital sun sensor (DSS). Test results indicated that the accuracy of the prototype was 0.01° within a cone FOV of 100°. Such an autonomous DSS could be equipped flexibly on a micro- or nano-satellite, especially for highly accurate remote sensing applications.
Always-on low-power optical system for skin-based touchless machine control.
Lecca, Michela; Gottardi, Massimo; Farella, Elisabetta; Milosevic, Bojan
2016-06-01
Embedded vision systems are smart energy-efficient devices that capture and process a visual signal in order to extract high-level information about the surrounding observed world. Thanks to these capabilities, embedded vision systems attract more and more interest from research and industry. In this work, we present a novel low-power optical embedded system tailored to detect the human skin under various illuminant conditions. We employ the presented sensor as a smart switch to activate one or more appliances connected to it. The system is composed of an always-on low-power RGB color sensor, a proximity sensor, and an energy-efficient microcontroller (MCU). The architecture of the color sensor allows a hardware preprocessing of the RGB signal, which is converted into the rg space directly on chip reducing the power consumption. The rg signal is delivered to the MCU, where it is classified as skin or non-skin. Each time the signal is classified as skin, the proximity sensor is activated to check the distance of the detected object. If it appears to be in the desired proximity range, the system detects the interaction and switches on/off the connected appliances. The experimental validation of the proposed system on a prototype shows that processing both distance and color remarkably improves the performance of the two separated components. This makes the system a promising tool for energy-efficient, touchless control of machines.
Design of two wheel self balancing car
NASA Astrophysics Data System (ADS)
He, Chun-hong; Ren, Bin
2018-02-01
This paper proposes a design scheme of the two-wheel self-balancing dolly, the integration of the gyroscope and accelerometer MPU6050 constitutes the car position detection device.System selects 32-bit MCU stmicroelectronics company as the control core, completed the processing of sensor signals, the realization of the filtering algorithm, motion control and human-computer interaction. Produced and debugging in the whole system is completed, the car can realize the independent balance under the condition of no intervention. The introduction of a suitable amount of interference, the car can adjust quickly to recover and steady state. Through remote control car bluetooth module complete forward, backward, turn left and other basic action..
Chen, Xi; Zhang, Yu; Xu, Bin; Cai, Zhongqi; Wang, Lin; Tian, Jinwen; Liu, Yuqi; Li, Yang
2016-09-01
Recent studies have shown that the mitochondrial DNA mutations are involved in the pathogenesis of hypertension. Our previous study identified mitochondrial tRNA(Ile) A4263G mutation in a large Chinese Han family with maternally-inherited hypertension. This mutation may contribute to mitochondrial Ca(2+) cycling dysfuntion, but the mechanism is unclear. Lymphoblastoid cell lines were derived from hypertensive and normotensive individuals, either with or without tRNA(Ile) A4263G mutation. The mitochondrial calcium ([Ca(2+)]m) in cells from hypertensive subjects with the tRNA(Ile) A4263G mutation, was lower than in cells from normotension or hypertension without mutation, or normotension with mutation (P<0.05). Meanwhile, cytosolic calcium ([Ca(2+)]c) in hypertensive with mutation cells was higher than another three groups. After exposure to caffeine, which could increase the [Ca(2+)]c by activating ryanodine receptor on endoplasmic reticulum, [Ca(2+)]c/[Ca(2+)]m increased higher than in hypertensive with mutation cells from another three groups. Moreover, MCU expression was decreased in hypertensive with mutation cells compared with in another three groups (P<0.05). [Ca(2+)]c increased and [Ca(2+)]m decreased after treatment with Ru360 (an inhibitor of MCU) or an siRNA against MCU. In this study we found decreased MCU expression in hypertensive with mutation cells contributed to dysregulated Ca(2+) uptake into the mitochondria, and cytoplasmic Ca(2+) overload. This abnormality might be involved in the underlying mechanisms of maternally inherited hypertension in subjects carrying the mitochondrial tRNA(Ile) A4263G mutation. Copyright © 2016 Elsevier Ltd. All rights reserved.
Improving Smart Home Concept with the Internet of Things Concept Using RaspberryPi and NodeMCU
NASA Astrophysics Data System (ADS)
Amri, Yasirli; Andri Setiawan, Mukhammad
2018-03-01
The Internet of things (IoT) is getting more tractions in recent years. One of the usage scenario of IoT is smart home. Smart home basically provides home automation for installed devices at home such as thermostat, lighting, air conditioning, etc and allows devices connected to the Internet to be monitored and controlled remotely by user. However many studies on smart home concept focusing only on few main features. They still lack of important usage of IoT i.e. providing energy efficiency, energy monitoring, dealing with security, and managing privacy. This paper proposes a smart home system with RaspberryPi and NodeMCU as the backend that not only serves as home automation and merely a switch replacement, but to also record and report important things to the owner of the house e.g. when someone trespasses the house (security perimeter), or to report the calculation of how much money has been spent in consuming the electrical appliances. We successfully examine our proposed system in a real life working scenario. The communication between user and the system is done using Telegram Bot.
The Impact of Emerging MEMS-Based Microsystems on US Defense Applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
STAPLE,BEVAN D.; JAKUBCZAK II,JEROME F.
2000-01-20
This paper examines the impact of inserting Micro-Electro-Mechanical Systems (MEMS) into US defense applications. As specific examples, the impacts of micro Inertial Measurement Units (IMUs), radio frequency MEMS (RF MEMS), and Micro-Opto-Electro-Mechanical Systems (MOEMS) to provide integrated intelligence, communication, and control to the defense infrastructure with increased affordability, functionality, and performance are highlighted.
Solvent Hold Tank Sample Results for MCU-16-1247-1248-1249: August 2016 Monthly Sample
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fondeur, F. F.; Jones, D. H.
Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-16-1247-1248-1249), pulled on 08/22/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-1247-1248-1249 indicated the Isopar™L concentration is above its nominal level (101%). The extractant (MaxCalix) and the modifier (CS-7SB) are 7% and 9 % below their nominal concentrations. The suppressor (TiDG) is 63% below its nominal concentration. This analysis confirms the solvent may require the addition of TiDG, and possibly of modifier and MaxCalix to restore then to nominal levels. Based on the current monthly sample, the levelsmore » of TiDG, Isopar™L, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterization and trimming additions to the solvent are recommended. At the time of writing this report, A solvent trim batch containing TiDG, modifier and MaxCalix, was added to the SHT (October 2016) and expect the concentration of these components to be at their nominal values.« less
Design-of-experiments to Reduce Life-cycle Costs in Combat Aircraft Inlets
NASA Technical Reports Server (NTRS)
Anderson, Bernhard H.; Baust, Henry D.; Agrell, Johan
2003-01-01
It is the purpose of this study to demonstrate the viability and economy of Design- of-Experiments (DOE), to arrive at micro-secondary flow control installation designs that achieve optimal inlet performance for different mission strategies. These statistical design concepts were used to investigate the properties of "low unit strength" micro-effector installation. "Low unit strength" micro-effectors are micro-vanes, set a very low angle-of incidence, with very long chord lengths. They are designed to influence the neat wall inlet flow over an extended streamwise distance. In this study, however, the long chord lengths were replicated by a series of short chord length effectors arranged in series over multiple bands of effectors. In order to properly evaluate the performance differences between the single band extended chord length installation designs and the segmented multiband short chord length designs, both sets of installations must be optimal. Critical to achieving optimal micro-secondary flow control installation designs is the understanding of the factor interactions that occur between the multiple bands of micro-scale vane effectors. These factor interactions are best understood and brought together in an optimal manner through a structured DOE process, or more specifically Response Surface Methods (RSM).
Charoensin, Suphachai; Eroglu, Emrah; Opelt, Marissa; Bischof, Helmut; Madreiter-Sokolowski, Corina T; Kirsch, Andrijana; Depaoli, Maria R; Frank, Saša; Schrammel, Astrid; Mayer, Bernd; Waldeck-Weiermair, Markus; Graier, Wolfgang F; Malli, Roland
2017-01-01
Mitochondrial Ca 2+ uptake regulates diverse endothelial cell functions and has also been related to nitric oxide (NO • ) production. However, it is not entirely clear if the organelles support or counteract NO • biosynthesis by taking up Ca 2+ . The objective of this study was to verify whether or not mitochondrial Ca 2+ uptake influences Ca 2+ -triggered NO • generation by endothelial NO • synthase (eNOS) in an immortalized endothelial cell line (EA.hy926), respective primary human umbilical vein endothelial cells (HUVECs) and eNOS-RFP (red fluorescent protein) expressing human embryonic kidney (HEK293) cells. We used novel genetically encoded fluorescent NO • probes, the geNOps, and Ca 2+ sensors to monitor single cell NO • and Ca 2+ dynamics upon cell treatment with ATP, an inositol 1,4,5-trisphosphate (IP 3 )-generating agonist. Mitochondrial Ca 2+ uptake was specifically manipulated by siRNA-mediated knock-down of recently identified key components of the mitochondrial Ca 2+ uniporter machinery. In endothelial cells and the eNOS-RFP expressing HEK293 cells we show that reduced mitochondrial Ca 2+ uptake upon the knock-down of the mitochondrial calcium uniporter (MCU) protein and the essential MCU regulator (EMRE) yield considerable attenuation of the Ca 2+ -triggered NO • increase independently of global cytosolic Ca 2+ signals. The knock-down of mitochondrial calcium uptake 1 (MICU1), a gatekeeper of the MCU, increased both mitochondrial Ca 2+ sequestration and Ca 2+ -induced NO • signals. The positive correlation between mitochondrial Ca 2+ elevation and NO • production was independent of eNOS phosphorylation at serine 1177 . Our findings emphasize that manipulating mitochondrial Ca 2+ uptake may represent a novel strategy to control eNOS-mediated NO • production. Copyright © 2016. Published by Elsevier Inc.
NASA Technical Reports Server (NTRS)
Anderson, Bernhard H.; Baust, Henry D.; Agrell, Johan
2002-01-01
It is the purpose of this study to demonstrate the viability and economy of Response Surface Methods (RSM) and Robustness Design Concepts (RDC) to arrive at micro-secondary flow control installation designs that maintain optimal inlet performance over a range of the mission variables. These statistical design concepts were used to investigate the robustness properties of 'low unit strength' micro-effector installations. 'Low unit strength' micro-effectors are micro-vanes set at very low angles-of-incidence with very long chord lengths. They were designed to influence the near wall inlet flow over an extended streamwise distance, and their advantage lies in low total pressure loss and high effectiveness in managing engine face distortion.
Daylight control system device and method
Paton, John Douglas
2007-03-13
A system and device for and a method of programming and controlling light fixtures is disclosed. A system in accordance with the present invention includes a stationary controller unit that is electrically coupled to the light fixtures. The stationary controller unit is configured to be remotely programmed with a portable commissioning device to automatically control the lights fixtures. The stationary controller unit and the portable commissioning device include light sensors, micro-computers and transceivers for measuring light levels, running programs, storing data and transmitting data between the stationary controller unit and the portable commissioning device. In operation, target light levels selected with the portable commissioning device and the controller unit is remotely programmed to automatically maintain the target level.
Daylight control system, device and method
Paton, John Douglas
2012-08-28
A system and device for and a method of programming and controlling light fixtures is disclosed. A system in accordance with the present invention includes a stationary controller unit that is electrically coupled to the light fixtures. The stationary controller unit is configured to be remotely programmed with a portable commissioning device to automatically control the lights fixtures. The stationary controller unit and the portable commissioning device include light sensors, micro-computers and transceivers for measuring light levels, running programs, storing data and transmitting data between the stationary controller unit and the portable commissioning device. In operation, target light levels selected with the portable commissioning device and the controller unit is remotely programmed to automatically maintain the target level.
Daylight control system device and method
Paton, John Douglas
2009-12-01
A system and device for and a method of programming and controlling light fixtures is disclosed. A system in accordance with the present invention includes a stationary controller unit that is electrically coupled to the light fixtures. The stationary controller unit is configured to be remotely programmed with a portable commissioning device to automatically control the lights fixtures. The stationary controller unit and the portable commissioning device include light sensors, micro-computers and transceivers for measuring light levels, running programs, storing data and transmitting data between the stationary controller unit and the portable commissioning device. In operation, target light levels selected with the portable commissioning device and the controller unit is remotely programmed to automatically maintain the target level.
A spectroscopy-based detector to monitor tomato growth condition in greenhouse
NASA Astrophysics Data System (ADS)
Yang, Ce; Li, Minzan; Cui, Di
2008-12-01
A spectroscopy-based detector is developed to measure the nitrogen and chlorophyll content of tomato leaves and then to predict the growth condition of tomato plants in greenhouse. The detector uses two wavebands, 527 nm and 762 nm, since it is proved that these wavebands are sensitive to nitrogen and chlorophyll content in plant leaves by previous field test. The detector contains: A Y-type optic fiber, two silicon photocells, a signal processing unit, and a MCU. Light reflection from tomato leaves is transmitted by the Y-type optic fiber to the surface of the silicon photo cells, which transfer optical signal into electrical signal. Then the analog signal is amplified to conform to the TTL level signal standard and finally converted to digital signal by MAX186. After that, the MCU carries on a series of actions, including data calculating, displaying and storage. Using the measured data, the Normalized Difference Vegetation Index (NDVI) is calculated to estimate the nitrogen and chlorophyll content in plant leaves. The result is directly displayed on an LCD screen. Users have an option in saving data, either into a USB-memory stick or into a database over the PC serial port. The detector is portable, inexpensive, and convenient, which make it meet farmers' need in China. The performance test shows that the growth model works very well, and the device has high accuracy in predicting the growth condition of tomato plants in greenhouse.
Design of the control system for full-color LED display based on MSP430 MCU
NASA Astrophysics Data System (ADS)
Li, Xue; Xu, Hui-juan; Qin, Ling-ling; Zheng, Long-jiang
2013-08-01
The LED display incorporate the micro electronic technique, computer technology and information processing as a whole, it becomes the most preponderant of a new generation of display media with the advantages of bright in color, high dynamic range, high brightness and long operating life, etc. The LED display has been widely used in the bank, securities trading, highway signs, airport and advertising, etc. According to the display color, the LED display screen is divided into monochrome screen, double color display and full color display. With the diversification of the LED display's color and the ceaseless rise of the display demands, the LED display's drive circuit and control technology also get the corresponding progress and development. The earliest monochrome screen just displaying Chinese characters, simple character or digital, so the requirements of the controller are relatively low. With the widely used of the double color LED display, the performance of its controller will also increase. In recent years, the full color LED display with three primary colors of red, green, blue and grayscale display effect has been highly attention with its rich and colorful display effect. Every true color pixel includes three son pixels of red, green, blue, using the space colour mixture to realize the multicolor. The dynamic scanning control system of LED full-color display is designed based on MSP430 microcontroller technology of the low power consumption. The gray control technology of this system used the new method of pulse width modulation (PWM) and 19 games show principle are combining. This method in meet 256 level grayscale display conditions, improves the efficiency of the LED light device, and enhances the administrative levels feels of the image. Drive circuit used 1/8 scanning constant current drive mode, and make full use of the single chip microcomputer I/O mouth resources to complete the control. The system supports text, pictures display of 256 grayscale full-color LED screen.
The Impact Of The MCU Life Extension Solvent On Sludge Batch 8 Projected Operating Windows
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peeler, D. K.; Edwards, T. B.; Stone, M. E.
2013-08-14
As a part of the Actinide Removal Process (ARP)/Modular Caustic Side Solvent Extraction Unit (MCU) Life Extension Project, a next generation solvent (NGS) and a new strip acid will be deployed. The strip acid will be changed from dilute nitric acid to dilute boric acid (0.01 M). Because of these changes, experimental testing or evaluations with the next generation solvent are required to determine the impact of these changes (if any) to Chemical Process Cell (CPC) activities, glass formulation strategies, and melter operations at the Defense Waste Processing Facility (DWPF). The introduction of the dilute (0.01M) boric acid stream intomore » the DWPF flowsheet has a potential impact on glass formulation and frit development efforts since B2O3 is a major oxide in frits developed for DWPF. Prior knowledge of this stream can be accounted for during frit development efforts but that was not the case for Sludge Batch 8 (SB8). Frit 803 has already been recommended and procured for SB8 processing; altering the frit to account for the incoming boron from the strip effluent (SE) is not an option for SB8. Therefore, the operational robustness of Frit 803 to the introduction of SE including its compositional tolerances (i.e., up to 0.0125M boric acid) is of interest and was the focus of this study. The primary question to be addressed in the current study was: What is the impact (if any) on the projected operating windows for the Frit 803 – SB8 flowsheet to additions of B2O3 from the SE in the Sludge Receipt and Adjustment Tank (SRAT)? More specifically, will Frit 803 be robust to the potential compositional changes occurring in the SRAT due to sludge variation, varying additions of ARP and/or the introduction of SE by providing access to waste loadings (WLs) of interest to DWPF? The Measurement Acceptability Region (MAR) results indicate there is very little, if any, impact on the projected operating windows for the Frit 803 – SB8 system regardless of the presence or absence of ARP and SE (up to 2 wt% B2O3 contained in the SRAT and up to 2000 gallons of ARP). It should be noted that 0.95 wt% B2O3 is the nominal projected concentration in the SRAT based on a 0.0125M boric acid flowsheet with 70,000 liters of SE being added to the SRAT. The impact on CPC processing of a 0.01M boric acid solution for elution of cesium during Modular Caustic Side Solvent Extraction Unit (MCU) processing has previously been evaluated by the Savannah River National Laboratory (SRNL). Increasing the acid strength to 0.0125M boric acid to account for variations in the boric acid strength has been reviewed versus the previous evaluation. The amount of acid from the boric acid represented approximately 5% of the total acid during the previous evaluation. An increase from 0.01 to 0.0125M boric acid represents a change of approximately 1.3% which is well within the error of the acid calculation. Therefore, no significant changes to CPC processing (hydrogen generation, metal solubilities, rheological properties, REDOX control, etc.) are expected from an increase in allowable boric acid concentration from 0.01M to 0.0125M.« less
a Movable Charging Unit for Green Mobility
NASA Astrophysics Data System (ADS)
ElBanhawy, E. Y.; Nassar, K.
2013-05-01
Battery swapping of electric vehicles (EVs) matter appears to be the swiftest and most convenient to users. The existence of swapping stations increases the feasibility of distributed energy storage via the electric grid. However, it is a cost-prohibitive way of charging. Early adaptors' preferences of /perceptions about EV system in general, has its inflectional effects on potential users hence the market penetration level. Yet, the charging matter of electric batteries worries the users and puts more pressure on them with the more rigorous planning-ahead they have to make prior to any trip. This paper presents a distinctive way of charging. It aims at making the overall charging process at ease. From a closer look into the literature, most of EVs' populations depend on domestic charge. Domestic charging gives them more confidence and increases the usability factor of the EV system. Nevertheless, they still need to count on the publically available charging points to reach their destination(s). And when it comes to multifamily residences, it becomes a thorny problem as these apartments do not have a room for charging outlets. Having said the irritating charging time needed to fatten the batteries over the day and the minimal average mileage drove daily, hypothetically, home delivery charging (Movable Charging Unit-MCU) would be a stupendous solution. The paper discusses the integration of shortest path algorithm problem with the information about EV users within a metropolitan area, developing an optimal route for a charging unit. This MCU delivers charging till homes whether by swapping batteries or by fast charging facility. Information about users is to be provided by the service provider of the neighbourhood, which includes charging patterns (timing, power capacity). This problem lies under the shortest path algorithms problem. It provides optimal route of charging that in return shall add more reliability and usability values and alleviate the charging/ limited range / daily planning anxieties. The model is in a very preliminary stage of development, future work is needed to elaborate on the model and developing a complete feasibility study.
DFB laser array driver circuit controlled by adjustable signal
NASA Astrophysics Data System (ADS)
Du, Weikang; Du, Yinchao; Guo, Yu; Li, Wei; Wang, Hao
2018-01-01
In order to achieve the intelligent controlling of DFB laser array, this paper presents the design of an intelligence and high precision numerical controlling electric circuit. The system takes MCU and FPGA as the main control chip, with compact, high-efficiency, no impact, switching protection characteristics. The output of the DFB laser array can be determined by an external adjustable signal. The system transforms the analog control model into a digital control model, which improves the performance of the driver. The system can monitor the temperature and current of DFB laser array in real time. The output precision of the current can reach ± 0.1mA, which ensures the stable and reliable operation of the DFB laser array. Such a driver can benefit the flexible usage of the DFB laser array.
Research on EME of real-time monitoring system
NASA Astrophysics Data System (ADS)
Meng, Ke; Guo, Jiang; Chai, Wei; Wu, Hongyan
2018-01-01
With the increase of the number of substations, the precision of electromagnetic environment parameters is higher. At present, there are many defects in the electromagnetic environment measuring system, such as the nonstandard data and the difficult reutilization. And many circuits with self-scale are controlled by switch, it has a great impact on the switching time and the service life of the device. A method of magnetic field range smooth switching is provided in this paper which is based on the magneto resistivity and the control of MCU, applying this method to the monitoring system which has functions of distributed data, real time data display, data storage and unified management etc.
Test case for VVER-1000 complex modeling using MCU and ATHLET
NASA Astrophysics Data System (ADS)
Bahdanovich, R. B.; Bogdanova, E. V.; Gamtsemlidze, I. D.; Nikonov, S. P.; Tikhomirov, G. V.
2017-01-01
The correct modeling of processes occurring in the fuel core of the reactor is very important. In the design and operation of nuclear reactors it is necessary to cover the entire range of reactor physics. Very often the calculations are carried out within the framework of only one domain, for example, in the framework of structural analysis, neutronics (NT) or thermal hydraulics (TH). However, this is not always correct, as the impact of related physical processes occurring simultaneously, could be significant. Therefore it is recommended to spend the coupled calculations. The paper provides test case for the coupled neutronics-thermal hydraulics calculation of VVER-1000 using the precise neutron code MCU and system engineering code ATHLET. The model is based on the fuel assembly (type 2M). Test case for calculation of power distribution, fuel and coolant temperature, coolant density, etc. has been developed. It is assumed that the test case will be used for simulation of VVER-1000 reactor and in the calculation using other programs, for example, for codes cross-verification. The detailed description of the codes (MCU, ATHLET), geometry and material composition of the model and an iterative calculation scheme is given in the paper. Script in PERL language was written to couple the codes.
Design of modular control system for grain dryers
NASA Astrophysics Data System (ADS)
He, Gaoqing; Liu, Yanhua; Zu, Yuan
In order to effectively control the temperature of grain drying bin, grain ,air outlet as well as the grain moisture, it designed the control system of 5HCY-35 which is based on MCU to adapt to all grains drying conditions, high drying efficiency, long life usage and less manually. The system includes: the control module of the constant temperature and the temperature difference control in drying bin, the constant temperature control of heating furnace, on-line testing of moisture, variety of grain-circulation speed control and human-computer interaction interface. Spatial curve simulation, which takes moisture as control objectives, controls the constant temperature and the temperature difference in drying bin according to preset parameter by the user or a list to reduce the grains explosive to ensure the seed germination percentage. The system can realize the intelligent control of high efficiency and various drying, the good scalability and the high quality.
Results of initial analyses of the salt (macro) batch 9 tank 21H qualification samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, T. B.
2015-10-01
Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Interim Salt Disposition Project (ISDP) Salt (Macro) Batch 9 for processing through the Actinide Removal Process (ARP) and the Modular Caustic-Side Solvent Extraction Unit (MCU). This document reports the initial results of the analyses of samples of Tank 21H. Analysis of the Tank 21H Salt (Macro) Batch 9 composite sample indicates that the material does not display any unusual characteristics or observations, such as floating solids, the presence of large amount of solids, or unusual colors. Further results on the chemistry and other tests willmore » be issued in the future.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, T. B.
Strip Effluent Hold Tank (SEHT) and Decontaminated Salt Solution Hold Tank (DSSHT) samples from several of the “microbatches” of Integrated Salt Disposition Project (ISDP) Salt Batch (“Macrobatch”) 9 have been analyzed for 238Pu, 90Sr, 137Cs, cations (Inductively Coupled Plasma Emission Spectroscopy - ICPES), and anions (Ion Chromatography Anions - IC-A). The analytical results from the current microbatch samples are similar to those from previous macrobatch samples. The Cs removal continues to be acceptable, with decontamination factors (DF) averaging 25700 (107% RSD). The bulk chemistry of the DSSHT and SEHT samples do not show any signs of unusual behavior, other thanmore » lacking the anticipated degree of dilution that is calculated to occur during Modular Caustic-Side Solvent Extraction Unit (MCU) processing.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, T. B.
Strip Effluent Hold Tank (SEHT) and Decontaminated Salt Solution Hold Tank (DSSHT) samples from several of the “microbatches” of Integrated Salt Disposition Project (ISDP) Salt Batch (“Macrobatch”) 8B have been analyzed for 238Pu, 90Sr, 137Cs, cations (Inductively Coupled Plasma Emission Spectroscopy - ICPES), and anions (Ion Chromatography Anions - IC-A). The analytical results from the current microbatch samples are similar to those from previous macrobatch samples. The Cs removal continues to be excellent, with decontamination factors (DF) averaging 22,100 (114% RSD). The bulk chemistry of the DSSHT and SEHT samples does not show any signs of unusual behavior, other thanmore » lacking the anticipated degree of dilution that is calculated to occur during Modular Caustic-Side Solvent Extraction Unit (MCU) processing.« less
Design of electric control system for automatic vegetable bundling machine
NASA Astrophysics Data System (ADS)
Bao, Yan
2017-06-01
A design can meet the requirements of automatic bale food structure and has the advantages of simple circuit, and the volume is easy to enhance the electric control system of machine carrying bunch of dishes and low cost. The bundle of vegetable machine should meet the sensor to detect and control, in order to meet the control requirements; binding force can be adjusted by the button to achieve; strapping speed also can be adjusted, by the keys to set; sensors and mechanical line connection, convenient operation; can be directly connected with the plug, the 220V power supply can be connected to a power source; if, can work, by the transmission signal sensor, MCU to control the motor, drive and control procedures for small motor. The working principle of LED control circuit and temperature control circuit is described. The design of electric control system of automatic dish machine.
Accuracy of early DMSA scan for VUR in young children with febrile UTI.
Zhang, Xin; Xu, Hong; Zhou, Lijun; Cao, Qi; Shen, Qian; Sun, Li; Fang, Xiaoyan; Guo, Wei; Zhai, Yihui; Rao, Jia; Pa, Mier; Zhao, Ruifang; Bi, Yunli
2014-01-01
To evaluate the accuracy of an acute (99m)Tc-dimercaptosuccinic acid (DMSA) scan in predicting dilating vesicoureteral reflux (VUR) among young children with a febrile urinary tract infection (UTI). The medical records of children (≤ 2 years of age), presenting with febrile UTI between January 2000 and December 2011, were retrospectively reviewed. A total of 523 children were included in this study, of whom 397 children (75.9%) had abnormal DMSA results and 178 children (34.0%) were identified as VUR on micturating cystourethrography (MCU). Among all the patients, the number of children with dilating VUR was 151 (28.9%). The rate of abnormal results on DMSA for the dilating VUR group was significantly higher than the rates for the non-VUR and low-grade VUR groups (P < .01). In the <6 months age group and ≥ 6 months age group, the sensitivities of DMSA in predicting dilating VUR were 96.15% and 100.0%, respectively, the negative predictive values were 97.26% and 100.0%, respectively, and the negative likelihood ratios were 0.0911 and 0.0000, respectively. For children ≤ 2 years of age with a febrile UTI, an acute DMSA scan is valuable in the exclusion of dilating VUR. The likelihood of the presence of dilating VUR on MCU is rather low when the result of DMSA is negative. DMSA should be conducted to assess the need for an MCU.
Effect of factory effluents on physiological and biochemical contents of Gossypium hirsutum l.
Muthusamy, A; Jayabalan, N
2001-10-01
The effect of sago and sugar factory effluents was studied on Gossypium hirsutum L. var. MCU 5 and MCU 11. Plants were irrigated with 0, 25, 50, 75 and 100% of effluents of both factories. At lower concentration (25%) of sugar factory effluents had stimulatory effect on all biochemical contents observed. Moreover, all concentration of sago factory effluents were found to have inhibitory effect on all biochemical contents except proline content which increased with increasing concentration of both the effluents. Plants growing on adjacent to sago and sugar factories or they irrigated with such type of polluted water, may accumulate the heavy metals found in both the effluents, at higher levels in plant products and if consumed may have similar effect on living organisms.
Mass Transfer And Hydraulic Testing Of The V-05 And V-10 Contactors With The Next Generation Solvent
DOE Office of Scientific and Technical Information (OSTI.GOV)
Herman, D. T.; Duignan, M. R.; Williams, M. R.
The Modular Caustic Side Solvent Extraction (CSSX) Unit (MCU) facility is actively pursuing the transition from the current BOBCalixC6 based solvent to the Next Generation Solvent (NGS)-MCU solvent. To support this integration of NGS into the MCU facilities, Savannah River Remediation (SRR) requested that Savannah River National Laboratory (SRNL) perform testing of a blend of the NGS (MaxCalix based solvent) with the current solvent (BOBCalixC6 based solvent) for the removal of cesium (Cs) from the liquid salt waste stream. This testing differs from prior testing by utilizing a blend of BOBCalixC6 based solvent and the NGS with the full (0.05more » M) concentration of the MaxCalix as well as a new suppressor, tris(3,7dimethyloctyl) guanidine. Single stage tests were conducted using the full size V-05 and V-10 centrifugal contactors installed at SRNL. These tests were designed to determine the mass transfer and hydraulic characteristics with the NGS solvent blended with the projected heel of the BOBCalixC6 based solvent that will exist in MCU at time of transition. The test program evaluated the amount of organic carryover and the droplet size of the organic carryover phases using several analytical methods. Stage efficiency and mass distribution ratios were determined by measuring Cs concentration in the aqueous and organic phases during single contactor testing. The nominal cesium distribution ratio, D(Cs) measured for extraction ranged from 37-60. The data showed greater than 96% stage efficiency for extraction. No significant differences were noted for operations at 4, 8 or 12 gpm aqueous salt simulant feed flow rates. The first scrub test (contact with weak caustic solution) yielded average scrub D(Cs) values of 3.3 to 5.2 and the second scrub test produced an average value of 1.8 to 2.3. For stripping behavior, the “first stage” D Cs) values ranged from 0.04 to 0.08. The efficiency of the low flow (0.27 gpm aqueous) was calculated to be 82.7%. The Spreadsheet Algorithm for Stagewise Solvent Extraction (SASSE) predicted equivalent DF for MCU from this testing is greater than 3,500 assuming 95% efficiency during extraction and 80% efficiency during scrub and strip. Hydraulically, the system performed very well in all tests. Target flows were easily obtained and stable throughout testing. Though some issues were encountered with plugging in the coalescer, they were not related to the solvent. No hydraulic upsets due to the solvent were experienced during any of the tests conducted. The first extraction coalescer element used in testing developed high pressure drop that made it difficult to maintain the target flow rates. Analysis showed an accumulation of sodium aluminosilicate solids. The coalescer was replaced with one from the same manufacturer’s lot and pressure drop was no longer an issue. Concentrations of Isopar™ L and Modifier were measured using semi-volatile organic analysis (SVOA) and high performance liquid chromatography (HPLC) to determine the amount of solvent carryover. For low-flow (0.27 gpm aqueous) conditions in stripping, SVOA measured the Isopar™ L post-contactor concentration to be 25 mg/L, HPLC measured 39 mg/L of Modifier. For moderate-flow (0.54 gpm aqueous) conditions, SVOA measured the Isopar™ L postcontactor to be ~69 mg/L, while the HPLC measured 56 mg/L for Modifier. For high-flow (0.8 gpm aqueous) conditions, SVOA measured the Isopar™ L post-contactor to be 39 mg/L. The post-coalescer (pre-decanter) measurements by SVOA for Isopar™ L were all less than the analysis detection limit of 10 mg/L. The HPLC measured 18, 22 and 20 mg/L Modifier for the low, medium, and high-low rates respectively. In extraction, the quantity of pre-coalescer Isopar™ L carryover measured by SVOA was ~280-410 mg/L at low flow (4 gpm aqueous), ~400-450 mg/L at moderate flow (8 gpm aqueous), and ~480 mg/L at high flow (12 gpm aqueous). The amount of post coalescer (pre-decanter) Isopar™ L carryover measured by SVOA was less than 45 mg/L for all flow rates. HPLC results for Modifier were 182, 217 and 222 mg/L for the post-contactor low, medium and high flow rates. The post-coalescer (pre-decanter) samples were measured to contain 12, 10 and 22 mg/L Modifier for the low, medium, and high flow rates. The carryover results and droplet size measurements were used to determine the decanter performance utilizing the decanter model developed by the ARES Corporation. Results show for the targeted salt flow rate of approximately 8 gpm, that over 93% of the solvent carryover from stripping is predicted to be recovered and over 96% solvent carryover from extraction is predicted to be recovered. This translates to a predicted solvent carryover of <3 ppm from stripping and <20 ppm solvent carryover from extraction. This projected performance at MCU is expected to be well within the operating limits and the historical performance for the baseline BOBCalixC6 based solvent. Droplet-size data obtained by MicroTrac™ S3400 analyzer consistently shows that the droplet size post-oalescer is significantly greater than the post-contactor or pre-coalescer samples. Increased flow rates did not show a consistent impact to the droplet size results. For the extraction testing, droplet size analysis showed that the post-contactor and pre-coalescer samples were essentially the same. The mean droplet sizes post-coalescer were less than the mean droplet sizes pre-coalescer with a very slight upward trend in the mean droplet size as the flow rate was increased. This result is probably due to the method of sampling. The larger post-coalescer drops immediately rise to the surface after leaving the coalescer element. The downstream sampling point was horizontally in-line with the element and therefore would only capture those organic droplets well mixed in the flowing aqueous stream.« less
An investigation of collisions between fiber positioning units in LAMOST
NASA Astrophysics Data System (ADS)
Liu, Xiao-Jie; Wang, Gang
2016-04-01
The arrangement of fiber positioning units in the LAMOST focal plane may lead to collisions during the fiber allocation process. To avoid these collisions, a software-based protection system has to abandon some targets located in the overlapping field of adjacent fiber units. In this paper, we first analyze the probability of collisions between fibers and infer their possible reasons. It is useful to solve the problem of collisions among fiber positioning units so as to improve the efficiency of LAMOST. Based on this, a collision handling system is designed by using a master-slave control structure between the micro control unit and microcomputer. Simulated experiments validate that the system can provide real-time inspection and swap information between the fiber unit controllers and the main controller.
Results of initial analyses of the salt (macro) batch 10 tank 21H qualification samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, T. B.
2017-01-01
Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Interim Salt Disposition Project (ISDP) Salt (Macro) Batch 10 for processing through the Actinide Removal Process (ARP) and the Modular Caustic-Side Solvent Extraction Unit (MCU). This document reports the initial results of the analyses of samples of Tank 21H. Analysis of the Tank 21H Salt (Macro) Batch 10 composite sample indicates that the material does not display any unusual characteristics or observations, such as floating solids, the presence of large amount of solids, or unusual colors. Further sample results will be reported in a futuremore » document. This memo satisfies part of Deliverable 3 of the Technical Task Request (TTR).« less
Results of initial analyses of the salt (macro) batch 11 Tank 21H qualification samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, T. B.
Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Interim Salt Disposition Project (ISDP) Salt (Macro) Batch 11 for processing through the Actinide Removal Process (ARP) and the Modular Caustic-Side Solvent Extraction Unit (MCU). This document reports the initial results of the analyses of samples of Tank 21H. Analysis of the Tank 21H Salt (Macro) Batch 11 composite sample indicates that the material does not display any unusual characteristics or observations, such as floating solids, the presence of large amounts of solids, or unusual colors. Further sample results will be reported in a futuremore » document. This memo satisfies part of Deliverable 3 of the Technical Task Request (TTR).« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Surkov, A. V., E-mail: surkov.andrew@gmail.com; Kochkin, V. N.; Pesnya, Yu. E.
2015-12-15
A comparison of measured and calculated neutronic characteristics (fast neutron flux and fission rate of {sup 235}U) in the core and reflector of the IR-8 reactor is presented. The irradiation devices equipped with neutron activation detectors were prepared. The determination of fast neutron flux was performed using the {sup 54}Fe (n, p) and {sup 58}Ni (n, p) reactions. The {sup 235}U fission rate was measured using uranium dioxide with 10% enrichment in {sup 235}U. The determination of specific activities of detectors was carried out by measuring the intensity of characteristic gamma peaks using the ORTEC gamma spectrometer. Neutron fields inmore » the core and reflector of the IR-8 reactor were calculated using the MCU-PTR code.« less
Safari, Roghaiyeh; Salimi, Reza; Tunca, Zeliha; Ozerdem, Aysegul; Ceylan, Deniz; Sakizli, Meral
2016-06-01
Calcium signaling is important for synaptic plasticity, generation of brain rhythms, regulating neuronal excitability, data processing and cognition. Impairment in calcium homeostasis contributed to the development of psychiatric disorders such as bipolar disorder (BP). MCU is the most important calcium transporter in mitochondria inner membrane responsible for influx of Ca[Formula: see text]. MICU1 is linked with MCU and has two canonical EF hands that are vital for its activity and regulates MCU-mediated Ca[Formula: see text] influx. In the current study, we aimed to investigate the role of genetic alteration of EF hand calcium binding motifs of MICU1 on the development of BP. We examined patients with BP, first degree relatives of these patients and healthy volunteers for mutations and polymorphisms in EF hand calcium binding motifs of MICU1. The result showed no SNP/mutation in BP patients, in healthy subjects and in first degree relatives. Additionally, alignment of the EF hand calcium binding regions among species (Gallus-gallus, Canis-lupus-familiaris, Bos-taurus, Mus-musculus, Rattus-norvegicus, Pan-troglodytes, Homosapiens and Danio-rerio) showed exactly the same amino acids (DLNGDGEVDMEE and DCDGNGELSNKE) except in one of the calcium binding domain of Danio-rerio that there was only one difference; leucine instead of Methionine. Our results showed that the SNP on EF-hand Ca[Formula: see text] binding domains of MICU1 gene had no effect in phenotypic characters of BP patients.
Solvent Hold Tank Sample Results for MCU-16-934-935-936: June 2016 Monthly Sample
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fondeur, F. F.; Jones, D. H.
2016-08-30
Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-16-934-935-936), pulled on 07/01/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-934-935-936 indicated the Isopar™L concentration is above its nominal level (101%). The modifier (CS-7SB) and the TiDG concentrations are 8% and 29 % below their nominal concentrations. This analysis confirms the solvent may require the addition of TiDG, and possibly of modifier. Based on the current monthly sample, the levels of TiDG, Isopar™L, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease withmore » time. Periodic characterization and trimming additions to the solvent are recommended. No impurities above the 1000 ppm level were found in this solvent by the Semi-Volatile Organic Analysis (SVOA). No impurities were observed in the Hydrogen Nuclear Magnetic Resonance (HNMR). However, up to 21.1 ± 4 micrograms of mercury per gram of solvent (or 17.5 μg/mL) was detected in this sample (as determined by the XRF method of undigested sample). The current gamma level (1.41E5 dpm/mL) confirmed that the gamma concentration has returned to previous levels (as observed in the late 2015 samples) where the process operated normally and as expected.« less
Ye, Jianglei
2017-09-08
A novel solid phase extraction (SPE) device driven by positive pressure was developed instead of negative pressure from a vacuum pump, in order to enrich organo chlorinated and pyrethroid pesticides in seawater. The water sampling bottles and the pipelines which touch water samples were made of plastic material without chlorine. In order to ensure the sealing and firmness, the whole device were tightened with nut and bolt. The inner pressure (0.1-0.3 MPa) in the water sampling bottle was provided by the small air pump (powered by 12 V cell) controlled by a microprogrammed control unit (MCU) and pressure sensor to keep the water flow rate (4.0-6.0 mL/min). The pre-conditioned SPE column can be used for the enrichment of pesticides within four weeks, and the loaded SPE column can be eluted for detection within six weeks with recoveries greater than 80%. The linearity of the method was good with the correlation coefficient more than 0.9. The limits of quantification (LOQs) were 0.8-6 ng/L. The recoveries of the pesticides at three spiked levels (3 parallel samples) were 86.1%-95.5% with the relative standard deviations less than 10%. The benzene hexachlorides (BHCs) and dichloro-diphenyl-trichloroethanes (DDTs) were detected in seawater samples. The device has good application in enriching organo chlorinated and pyrethroid pesticides in seawater.
Next Generation Solvent (NGS): Development for Caustic-Side Solvent Extraction of Cesium
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moyer, Bruce A.; Birdwell, Jr, Joseph F.; Bonnesen, Peter V.
This report summarizes the FY 2010 and 2011 accomplishments at Oak Ridge National Laboratory (ORNL) in developing the Next Generation Caustic-Side Solvent Extraction (NG-CSSX) process, referred to commonly as the Next Generation Solvent (NGS), under funding from the U.S. Department of Energy, Office of Environmental Management (DOE-EM), Office of Technology Innovation and Development. The primary product of this effort is a process solvent and preliminary flowsheet capable of meeting a target decontamination factor (DF) of 40,000 for worst-case Savannah River Site (SRS) waste with a concentration factor of 15 or higher in the 18-stage equipment configuration of the SRS Modularmore » Caustic-Side Solvent Extraction Unit (MCU). In addition, the NG-CSSX process may be readily adapted for use in the SRS Salt Waste Processing Facility (SWPF) or in supplemental tank-waste treatment at Hanford upon appropriate solvent or flowsheet modifications. Efforts in FY 2010 focused on developing a solvent composition and process flowsheet for MCU implementation. In FY 2011 accomplishments at ORNL involved a wide array of chemical-development activities and testing up through single-stage hydraulic and mass-transfer tests in 5-cm centrifugal contactors. Under subcontract from ORNL, Argonne National Laboratory (ANL) designed a preliminary flowsheet using ORNL cesium distribution data, and Tennessee Technological University confirmed a chemical model for cesium distribution ratios (DCs) as a function of feed composition. Interlaboratory efforts were coordinated with complementary engineering tests carried out (and reported separately) by personnel at Savannah River National Laboratory (SRNL) and Savannah River Remediation (SRR) with helpful advice by Parsons Engineering and General Atomics on aspects of possible SWPF implementation.« less
Next Generation Solvent Development for Caustic-Side Solvent Extraction of Cesium
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moyer, Bruce A.; Birdwell, Joseph F.; Bonnesen, Peter V.
This report summarizes the FY 2010 and 2011 accomplishments at Oak Ridge National Laboratory (ORNL) in developing the Next Generation Caustic-Side Solvent Extraction (NG-CSSX) process, referred to commonly as the Next Generation Solvent (NGS), under funding from the U.S. Department of Energy, Office of Environmental Management (DOE-EM), Office of Technology Innovation and Development. The primary product of this effort is a process solvent and preliminary flowsheet capable of meeting a target decontamination factor (DF) of 40,000 for worst-case Savannah River Site (SRS) waste with a concentration factor of 15 or higher in the 18-stage equipment configuration of the SRS Modularmore » Caustic-Side Solvent Extraction Unit (MCU). In addition, the NG-CSSX process may be readily adapted for use in the SRS Salt Waste Processing Facility (SWPF) or in supplemental tank-waste treatment at Hanford upon appropriate solvent or flowsheet modifications. Efforts in FY 2010 focused on developing a solvent composition and process flowsheet for MCU implementation. In FY 2011 accomplishments at ORNL involved a wide array of chemical-development activities and testing up through single-stage hydraulic and mass-transfer tests in 5-cm centrifugal contactors. Under subcontract from ORNL, Argonne National Laboratory (ANL) designed a preliminary flowsheet using ORNL cesium distribution data, and Tennessee Technological University confirmed a chemical model for cesium distribution ratios (DCs) as a function of feed composition. Inter laboratory efforts were coordinated with complementary engineering tests carried out (and reported separately) by personnel at Savannah River National Laboratory (SRNL) and Savannah River Remediation (SRR) with helpful advice by Parsons Engineering and General Atomics on aspects of possible SWPF implementation.« less
Analysis of long-time operation of micro-cogeneration unit with fuel cell
NASA Astrophysics Data System (ADS)
Patsch, Marek; Čaja, Alexander
2015-05-01
Micro-cogeneration is cogeneration with small performance, with maximal electric power up to 50 kWe. On the present, there are available small micro-cogeneration units with small electric performance, about 1 kWe, which are usable also in single family houses or flats. These micro-cogeneration units operate on principle of conventional combustion engine, Stirling engine, steam engine or fuel cell. Micro-cogeneration units with fuel cells are new progressive developing type of units for single family houses. Fuel cell is electrochemical device which by oxidation-reduction reaction turn directly chemical energy of fuel to electric power, secondary products are pure water and thermal energy. The aim of paper is measuring and evaluation of operation parameters of micro-cogeneration unit with fuel cell which uses natural gas as a fuel.
NASA Technical Reports Server (NTRS)
Chullen, Cinda
2017-01-01
Functional Requirements for the Carbon Dioxide and Humidity Control Unit (CDHCU): The CDHCU is a component of the Exploration Portable Life Support System (xPLSS) to provide carbon dioxide (CO2) and humidity control within the spacesuit for a crewmember to perform extravehicular activities (EVA) in vacuum (micro-g), lunar, and Mars environments for up to 8 hours continuous, and during EVA preparation in airlocks or support vehicles for an additional 2 hours (TBR) continuous.
Information processing in dendrites I. Input pattern generalisation.
Gurney, K N
2001-10-01
In this paper and its companion, we address the question as to whether there are any general principles underlying information processing in the dendritic trees of biological neurons. In order to address this question, we make two assumptions. First, the key architectural feature of dendrites responsible for many of their information processing abilities is the existence of independent sub-units performing local non-linear processing. Second, any general functional principles operate at a level of abstraction in which neurons are modelled by Boolean functions. To accommodate these assumptions, we therefore define a Boolean model neuron-the multi-cube unit (MCU)-which instantiates the notion of the discrete functional sub-unit. We then use this model unit to explore two aspects of neural functionality: generalisation (in this paper) and processing complexity (in its companion). Generalisation is dealt with from a geometric viewpoint and is quantified using a new metric-the set of order parameters. These parameters are computed for threshold logic units (TLUs), a class of random Boolean functions, and MCUs. Our interpretation of the order parameters is consistent with our knowledge of generalisation in TLUs and with the lack of generalisation in randomly chosen functions. Crucially, the order parameters for MCUs imply that these functions possess a range of generalisation behaviour. We argue that this supports the general thesis that dendrites facilitate input pattern generalisation despite any local non-linear processing within functionally isolated sub-units.
Falla, Deborah; Lindstrøm, Rene; Rechter, Lotte; Farina, Dario
2010-05-01
To compare the behavior of sternocleidomastoid motor units of patients with chronic neck pain and healthy controls. Nine women (age, 40.4+/-3.5 yr) with chronic neck pain and nine age- and gender-matched healthy controls participated. Surface and intramuscular EMG were recorded from the sternocleidomastoid muscle bilaterally as subjects performed isometric contractions of 10-s duration in the horizontal plane at a force of 15 N in eight directions (0-360 degrees ; 45 degrees intervals) and isometric contractions at 15 and 30 N force with continuous change in force direction in the range 0-360 degrees . Motor unit behavior was monitored during the 10-s contractions and the subsequent resting periods. The mean motor unit discharge rate depended on the direction of force in the control subjects (P<0.05) but not in the patients. Moreover, in three of the nine patients, but in none of the controls, single motor unit activity continued for 8.1+/-6.1s upon completion of the contraction. The surface EMG amplitude during the circular contraction at 15N was greater for the patients (43.5+/-54.2 microV) compared to controls (16.9+/-14.9 microV; P<0.05). The modulation in discharge rate of individual motor units with force direction is reduced in the sternocleidomastoid muscle in patients with neck pain, with some patients showing prolonged motor unit activity when they were instructed to rest. These observations suggest that chronic neck pain affects the change in neural drive to muscles with force direction. Copyright 2009 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fondeur, F. F.; Jones, D. H.
Savannah River National Laboratory (SRNL) received one set of three Solvent Hold Tank (SHT) samples (MCU-16-1363-1364-1365), pulled on 11/15/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-1363-1364-1365 indicated the Isopar™L concentration is at its nominal level (100%). The extractant (MaxCalix) and the modifier (CS- 7SB) are 8% and 2 % below their nominal concentrations. The suppressor (TiDG) is 7% below its nominal concentration. This analysis confirms the trim and Isopar™ additions to the solvent in November. This analysis also indicates the solvent did not require further additions. Based on the current monthlymore » sample, the levels of TiDG, Isopar™L, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterization and trimming additions to the solvent are recommended.« less
Zhang, Zhiyong; Yang, Xuandong; Li, Kaiyang
2005-06-01
A new kind of method for intraperitoneal hyperthermic chemotherapy has been proved to be very effective for the therapy of gastrointestinal cancer. In this article is reported an intraperitoneal perfusion machine which is designed for instituting the treatment. The liquor of the chemotherapy drug is infused into the abdomen after being heated by heating system; the liquor flows out of the abdomen is abandoned. The temperature of heating and the velocity of flow are controlled by MCU, thus the temperature of the liquor of the chemotherapy drug in the abdomen can be adjusted to the most favarable temperature.
Shenoi, V N; Ali, S Z; Prasad, N G
2016-02-01
In holometabolous animals such as Drosophila melanogaster, larval crowding can affect a wide range of larval and adult traits. Adults emerging from high larval density cultures have smaller body size and increased mean life span compared to flies emerging from low larval density cultures. Therefore, adaptation to larval crowding could potentially affect adult longevity as a correlated response. We addressed this issue by studying a set of large, outbred populations of D. melanogaster, experimentally evolved for adaptation to larval crowding for 83 generations. We assayed longevity of adult flies from both selected (MCUs) and control populations (MBs) after growing them at different larval densities. We found that MCUs have evolved increased mean longevity compared to MBs at all larval densities. The interaction between selection regime and larval density was not significant, indicating that the density dependence of mean longevity had not evolved in the MCU populations. The increase in longevity in MCUs can be partially attributed to their lower rates of ageing. It is also noteworthy that reaction norm of dry body weight, a trait probably under direct selection in our populations, has indeed evolved in MCU populations. To the best of our knowledge, this is the first report of the evolution of adult longevity as a correlated response of adaptation to larval crowding. © 2015 European Society For Evolutionary Biology. Journal of Evolutionary Biology © 2015 European Society For Evolutionary Biology.
CaMKII determines mitochondrial stress responses in heart
Joiner, Mei-ling A.; Koval, Olha M.; Jingdong, Li; He, B. Julie; Allamargot, Chantal; Gao, Zhan; Luczak, Elizabeth D.; Hall, Duane D.; Fink, Brian D.; Chen, Biyi; Yang, Jinying; Moore, Steven A.; Scholz, Thomas D.; Strack, Stefan; Mohler, Peter J.; Sivitz, William I.; Song, Long-Sheng; Anderson, Mark E.
2012-01-01
Myocardial cell death is initiated by excessive mitochondrial Ca2+ entry, causing Ca2+ overload, mitochondrial permeability transition pore (mPTP) opening and dissipation of the mitochondrial inner membrane potential (ΔΨm)1,2. However, the signaling pathways that control mitochondrial Ca2+ entry through the inner membrane mitochondrial Ca2+ uniporter (MCU)3–5 are not known. The multifunctional Ca2+ and calmodulin-dependent protein kinase II (CaMKII) is activated in ischemia reperfusion (I/R), myocardial infarction (MI) and neurohumoral injury, common causes of myocardial death and heart failure, suggesting CaMKII could couple disease stress to mitochondrial injury. Here we show that CaMKII promotes mPTP opening and myocardial death by increasing MCU current (IMCU). Mitochondrial-targeted CaMKII inhibitory protein or cyclosporin A (CsA), an mPTP antagonist with clinical efficacy in I/R injury6, equivalently prevent mPTP opening, ΔΨm deterioration and diminish mitochondrial disruption and programmed cell death in response to I/R injury. Mice with myocardial and mitochondrial-targeted CaMKII inhibition are resistant to I/R injury, MI and neurohumoral injury, suggesting pathological actions of CaMKII are substantially mediated by increasing IMCU. Our findings identify CaMKII activity as a central mechanism for mitochondrial Ca2+ entry and suggest mitochondrial-targeted CaMKII inhibition could prevent or reduce myocardial death and heart failure dysfunction in response to common experimental forms of pathophysiological stress. PMID:23051746
Evaluation of nano-technology-modified zirconia oral implants: a study in rabbits.
Lee, Jaebum; Sieweke, Janet H; Rodriguez, Nancy A; Schüpbach, Peter; Lindström, Håkan; Susin, Cristiano; Wikesjö, Ulf M E
2009-07-01
The objective of this study was to screen candidate nano-technology-modified, micro-structured zirconia implant surfaces relative to local bone formation and osseointegration. Proprietary nano-technology surface-modified (calcium phosphate: CaP) micro-structured zirconia implants (A and C), control micro-structured zirconia implants (ZiUnite), and titanium porous oxide implants (TiUnite) were implanted into the femoral condyle in 40 adult male New Zealand White rabbits. Each animal received one implant in each hind leg; thus, 20 animals received A and C implants and 20 animals received ZiUnite and TiUnite implants in contralateral hind legs. Ten animals/group were euthanized at weeks 3 and 6 when biopsies of the implant sites were processed for histometric analysis using digital photomicrographs produced using backscatter scanning electron microscopy. The TiUnite surface demonstrated significantly greater bone-implant contact (BIC) (77.6+/-2.6%) compared with the A (64.6+/-3.6%) and C (62.2+/-3.1%) surfaces at 3 weeks (p<0.05). Numerical differences between ZiUnite (70.5+/-3.1%) and A and C surfaces did not reach statistical significance (p>0.05). Similarly, there were non-significant differences between the TiUnite and the ZiUnite surfaces (p>0.05). At 6 weeks, there were no significant differences in BIC between the TiUnite (67.1+/-4.2%), ZiUnite (69.7+/-5.7%), A (68.6+/-1.9%), and C (64.5+/-4.1%) surfaces (p>0.05). TiUnite and ZiUnite implant surfaces exhibit high levels of osseointegration that, in this model, confirm their advanced osteoconductive properties. Addition of CaP nano-technology to the ZiUnite surface does not enhance the already advanced osteoconductivity displayed by the TiUnite and ZiUnite implant surfaces.
Catalyzed Combustion In Micro-Propulsion Devices: Project Status
NASA Technical Reports Server (NTRS)
Sung, C. J.; Schneider, S. J.
2003-01-01
In recent years, there has been a tendency toward shrinking the size of spacecraft. New classes of spacecraft called micro-spacecraft have been defined by their mass, power, and size ranges. Spacecraft in the range of 20 to 100 kg represent the class most likely to be utilized by most small sat users in the near future. There are also efforts to develop 10 to 20 kg class spacecraft for use in satellite constellations. More ambitious efforts will be to develop spacecraft less than 10 kg, in which MEMS fabrication technology is required. These new micro-spacecraft will require new micro-propulsion technology. Although micro-propulsion includes electric propulsion approaches, the focus of this proposed program is micro-chemical propulsion which requires the development of microcombustors. As combustors are scaled down, the surface to volume ratio increases. The heat release rate in the combustor scales with volume, while heat loss rate scales with surface area. Consequently, heat loss eventually dominates over heat release when the combustor size becomes smaller, thereby leading to flame quenching. The limitations imposed on chamber length and diameter has an immediate impact on the degree of miniaturization of a micro-combustor. Before micro-combustors can be realized, such a difficulty must be overcome. One viable combustion alternative is to take advantage of surface catalysis. Micro-chemical propulsion for small spacecraft can be used for primary thrust, orbit insertion, trajectory-control, and attitude control. Grouping micro-propulsion devices in arrays will allow their use for larger thrust applications. By using an array composed of hundreds or thousands of micro-thruster units, a particular configuration can be arranged to be best suited for a specific application. Moreover, different thruster sizes would provide for a range of thrust levels (from N s to mN s) within the same array. Several thrusters could be fired simultaneously for thrust levels higher than the basic units, or in a rapid sequence in order to provide gradual but steady low-g acceleration. These arrays of micro-propulsion systems would offer unprecedented flexibility and redundancy for satellite propulsion and reaction control for launch vehicles. A high-pressure bi-propellant micro-rocket engine is already being developed using MEMS technology. High pressure turbopumps and valves are to be incorporated onto the rocket chip . High pressure combustion of methane and O2 in a micro-combustor has been demonstrated without catalysis, but ignition was established with a spark. This combustor has rectangular dimensions of 1.5 mm by 8 mm (hydraulic diameter 3.9 mm) and a length of 4.5 mm and was operated at 1250 kPa with plans to operate it at 12.7 MPa. These high operating pressures enable the combustion process in these devices, but these pressures are not practical for pressure fed satellite propulsion systems. Note that the use of these propellants requires an ignition system and that the use of a spark would impose a size limitation to this micro-propulsion device because the spark unit cannot be shrunk proportionately with the thruster. Results presented in this paper consist of an experimental evaluation of the minimum catalyst temperature for initiating/supporting combustion in sub-millimeter diameter tubes. The tubes are resistively heated and reactive premixed gases are passed through the tubes. Tube temperature and inlet pressure are monitored for an indication of exothermic reactions and composition changes in the gases.
A role for mitochondria in antigen processing and presentation
Bonifaz, Laura C; Cervantes-Silva, Mariana P; Ontiveros-Dotor, Elizabeth; López-Villegas, Edgar O; Sánchez-García, F Javier
2015-01-01
Immune synapse formation is critical for T-lymphocyte activation, and mitochondria have a role in this process, by localizing close to the immune synapse, regulating intracellular calcium concentration, and providing locally required ATP. The interaction between antigen-presenting cells (APCs) and T lymphocytes is a two-way signalling process. However, the role of mitochondria in APCs during this process remains unknown. For APCs to be able to activate T lymphocytes, they must first engage in an antigen-uptake, -processing and -presentation process. Here we show that hen egg white lysozyme (HEL) -loaded B lymphocytes, as a type of APC, undergo a small but significant mitochondrial depolarization by 1–2 hr following antigen exposure, suggesting an increase in their metabolic demands. Inhibition of ATP synthase (oligomycin) or mitochondrial Ca2+ uniporter (MCU) (Ruthenium red) had no effect on antigen uptake. Therefore, antigen processing and antigen presentation were further analysed. Oligomycin treatment reduced the amount of specific MHC–peptide complexes but not total MHC II on the cell membrane of B lymphocytes, which correlated with a decrease in antigen presentation. However, oligomycin also reduced antigen presentation by B lymphocytes, which endogenously express HEL and by B lymphocytes loaded with the HEL48–62 peptide, although to a lesser extent. ATP synthase inhibition and MCU inhibition had a clear inhibitory effect on antigen processing (DQ-OVA). Taken together these results suggest that ATP synthase and MCU are relevant for antigen processing and presentation. Finally, APC mitochondria were found to re-organize towards the APC–T immune synapse. PMID:25251370
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fondeur, F. F.; Jones, D. H.
Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-15-815-816-817-818-819-820), pulled on 11/29/2015 for analysis. The samples were inspected, combined, and analyzed for composition. Chemical analysis of the composite sample MCU-15-815-816-817-818-819-820 indicated the TiDG, Isopar™L, and MaxCalix are at nominal levels. The modifier concentration is 3% below its nominal concentration. This analysis confirms the addition of TiDG, MaxCalix, and modifier to the solvent on November 28, 2015. Based on the current monthly sample, the levels of TiDG, Isopar™L, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterizationmore » and trimming additions to the solvent are recommended. No impurities above the 1000 ppm level were found in this solvent by the Semi-Volatile Organic Analysis (SVOA). No impurities were observed in the Hydrogen Nuclear Magnetic Resonance (HNMR). However, up to 12.5 ± 3 micrograms of mercury per gram of solvent (or 10.4 μg/mL) was detected in this sample. The solids residues found at the bottom of the p-nut vial from sample MCU-15-815 were determined to be left-over pipe residues that were flushed into the sample and they were found to have no impact on the solvent purity or on the chemical and physical properties of the solvent. The laboratory will continue to monitor the quality of the solvent in particular for any new impurities or degradation of the solvent components.« less
Hong, Quan; Qi, Ka; Feng, Zhe; Huang, Zhiyong; Cui, Shaoyuan; Wang, Liyuan; Fu, Bo; Ding, Rui; Yang, Jurong; Chen, Xiangmei; Wu, Di
2012-05-01
Uric acid (UA) has proven to be a causal agent in endothelial dysfunction in which ROS production plays an important role. Calcium overload in mitochondria can promote the mitochondrial production of ROS. We hypothesize that calcium transduction in mitochondria contributes to UA-induced endothelial dysfunction. We first demonstrated that high concentrations of UA cause endothelial dysfunction, marked by a reduction in eNOS protein expression and NO release in vitro. We further found that a high concentration of UA increased levels of [Ca2+]mito, total intracellular ROS, H2O2, and mitochondrial O2·-, and Δψmito but not the [Ca2+]cyt level. When the mitochondrial calcium channels NCXmito and MCU were blocked by CGP-37157 and Ru360, respectively, the UA-induced increases in the levels of [Ca2+]mito and total intracellular ROS were significantly reduced. Mitochondrial levels of O2·- and Δψmito were reduced by inhibition of NCXmito but not of MCU. Moreover, inhibition of NCXmito, but not of MCU, blocked the UA-induced reductions in eNOS protein expression and NO release. The increased generation of mitochondrial O2·- induced by a high concentration of UA is triggered by mitochondrial calcium overload and ultimately leads to endothelial dysfunction. In this process, the activation of NCXmito is the major cause of the influx of calcium into mitochondria. Our results provide a new pathophysiological mechanism for UA-induced endothelial dysfunction and may offer a new therapeutic target for clinicians. Copyright © 2012 Elsevier Ltd. All rights reserved.
Wisdom Appliance Control System
NASA Astrophysics Data System (ADS)
Hendrick; Jheng, Jyun-Teng; Tsai, Chen-Chai; Liou, Jia-Wei; Wang, Zhi-Hao; Jong, Gwo-Jia
2017-07-01
Intelligent appliances wisdom involves security, home care, convenient and energy saving, but the home automation system is still one of the core unit, and also using micro-processing electronics technology to centralized and control the home electrical products and systems, such as: lighting, television, fan, air conditioning, stereo, it composed of front-controller systems and back-controller panels, user using front-controller to control command, and then through the back-controller to powered the device.
[An automatic system controlled by microcontroller for carotid sinus perfusion].
Yi, X L; Wang, M Y; Fan, Z Z; He, R R
2001-08-01
To establish a new method for controlling automatically the carotid perfusion pressure. A cheap practical automatic perfusion unit based on AT89C2051 micro controller was designed. The unit, LDB-M perfusion pump and the carotid sinus of an animal constituted an automatic perfusion system. This system was able to provide ramp and stepwise updown perfusion pattern and has been used in the research of baroreflex. It can insure the precision and reproducibility of perfusion pressure curve, and improve the technical level in corresponding medical field.
All Sky Cloud Coverage Monitoring for SONG-China Project
NASA Astrophysics Data System (ADS)
Tian, J. F.; Deng, L. C.; Yan, Z. Z.; Wang, K.; Wu, Y.
2016-05-01
In order to monitor the cloud distributions at Qinghai station, a site selected for SONG (Stellar Observations Network Group)-China node, the design of the proto-type of all sky camera (ASC) applied in Xinglong station is adopted. Both hardware and software improvements have been made in order to be more precise and deliver quantitative measurements. The ARM (Advanced Reduced Instruction Set Computer Machine) MCU (Microcontroller Unit) instead of PC is used to control the upgraded version of ASC. A much higher reliability has been realized in the current scheme. Independent of the positions of the Sun and Moon, the weather conditions are constantly changing, therefore it is difficult to get proper exposure parameters using only the temporal information of the major light sources. A realistic exposure parameters for the ASC can actually be defined using a real-time sky brightness monitor that is also installed at the same site. The night sky brightness value is a very sensitive function of the cloud coverage, and can be accurately measured by the sky quality monitor. We study the correlation between the exposure parameter and night sky brightness value, and give the mathematical relation. The images of the all sky camera are inserted into database directly. All sky quality images are archived in FITS format which can be used for further analysis.
Partos, Timea R; Borland, Ron; Thrasher, James F; Li, Lin; Yong, Hua-Hie; O'Connor, Richard J; Siahpush, Mohammad
2014-08-01
This study explored the association between six "micro indicators" of concern about smoking (1. stubbing out cigarettes before finishing; 2. forgoing cigarettes due to packet warning labels; thinking about... 3. the harms to oneself of smoking; 4. the harms to others of one's smoking; 5. the bad conduct of tobacco companies; and 6. money spent on cigarettes) and cessation outcomes (making quit attempts, and achieving at least six months of sustained abstinence) among adult smokers from Australia, Canada, the United Kingdom, and the United States of America. Participants were 12,049 individuals from five survey waves of the International Tobacco Control Four Country Survey (interviewed between 2002 and 2006, and followed-up approximately one year later). Generalized estimating equation logistic regression analysis was used, enabling us to control for within-participant correlations due to possible multiple responses by the same individual over different survey waves. The frequency of micro indicators predicted making quit attempts, with premature stubbing out, forgoing, and thinking about the harms to oneself of smoking being particularly strong predictors. An interaction effect with expressed intention to quit was observed, such that stubbing out and thinking about the harms on oneself predicted quit attempts more strongly among smokers with no expressed plans to quit. In contrast, there was a negative association between some micro indicators and sustained abstinence, with more frequent stubbing out, forgoing, and thinking about money spent on cigarettes associated with a reduced likelihood of subsequently achieving sustained abstinence. In countries with long-established tobacco control programs, micro indicators index both high motivation by smokers to do something about their smoking at least partly independent of espoused intention and, especially those indicators not part of a direct pathway to quitting, reduced capacity to quit successfully. Copyright © 2014 Elsevier Ltd. All rights reserved.
Kumar, Annamalai Senthil; Tanase, Tomoaki; Iida, Masayasu
2007-01-16
Nanostructured molecular film containing the (micro-hydroxo)bis(micro-carboxylato) diruthenium(III) units, [RuIII2(micro-OH)(micro-CH3COO)2(HBpz3)2]+ ({RuIII2(micro-OH)}), was prepared by an in situ conversion of its micro-oxo precursor, [RuIII2(micro-O)(micro-CH3COO)2(HBpz3)2] ({RuIII2(micro-O)}), in a Nafion membrane matrix, where HBpz3 is hydrotris(1-pyrazolyl)borate. The conversion procedure results in fine nanoparticle aggregates of the {RuIII2(micro-OH)} units in the Nafion membrane (Nf-{RuIII2(micro-OH)}), where an average particle size (4.1 +/- 2.3 nm) is close to the Nafion's cluster dimension of approximately 4 nm. Chemically modified electrodes by using the Nafion molecular membrane films (Nf-{RuIII2(micro-OH)}-MMFEs) were further developed on ITO/glass and glassy carbon electrode (GCE) surfaces, and a selective reduction of nitrosonium ion (NO+), presumably through reaction of a {RuIIRuIII(micro-OH)} mixed-valence state with HNO2, was demonstrated without interference by molecular oxygen in an acidic aqueous solution. The Nf-{RuIII2(micro-OH)}-MMFEs are stable even in a physiological condition (pH 7), where the naked {RuIII2(-OH)} complex is readily transformed into its deprotonated {RuIII2(micro-O)} form, demonstrating an unusual stabilizing effects for the {RuIII2(micro-OH)} unit by the Nafion cluster environment.
Solvent hold tank sample results for MCU-15-914-915-916. December 2015 Monthly sample
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fondeur, F. F.; Jones, D. H.
2016-03-01
Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-15-914-915-916), pulled on 12/22/2015 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-15-914-915-916 indicated the TiDG, Isopar™L, and MaxCalix are at nominal levels. The modifier concentration is 3% below its nominal concentration. This analysis confirms the addition of TiDG, MaxCalix, and modifier to the solvent in November 2015. Based on the current monthly sample, the levels of TiDG, Isopar™L, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterization and trimming additionsmore » to the solvent are recommended. No impurities above the 1000 ppm level were found in this solvent by the Semi-Volatile Organic Analysis (SVOA). No impurities were observed in the Hydrogen Nuclear Magnetic Resonance (HNMR). However, the Fourier transform infra-red spectroscopy (FTIR) method detected trace levels (a few ppm) of amides (more indicative of bacteria than a possible degradation product of TiDG). In addition, up to 18 ± 4 micrograms of mercury per gram of solvent (or 14.8 μg/mL) was detected in this sample. The current gamma concentration level (8.48E4 dpm/mL) confirmed that the gamma concentration has returned to the previous level where the process operated normally as expected. The laboratory will continue to monitor the quality of the solvent in particular for any new impurities or degradation of the solvent components.« less
Solvent hold tank sample results for MCU-16-53-55. January 2016 Monthly sample
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fondeur, F. F.; Jones, D. H.
Savannah River National Laboratory (SRNL) received one set of Solvent Hold Tank (SHT) samples (MCU-16-53-54-55), pulled on 01/25/2016 for analysis. The samples were combined and analyzed for composition. Analysis of the composite sample MCU-16-53-54-55 indicated the Isopar™L, and MaxCalix are at nominal levels. The modifier and TiDG concentrations are 3% and 23 % below their nominal concentrations. This analysis confirms the addition of TiDG, MaxCalix, and modifier to the solvent on November 28, 2015. Based on the current monthly sample, the levels of TiDG, Isopar™L, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time.more » Periodic characterization and trimming additions to the solvent are recommended. No impurities above the 1000 ppm level were found in this solvent by the Semi-Volatile Organic Analysis (SVOA). No impurities were observed in the Hydrogen Nuclear Magnetic Resonance (HNMR). However, the Fourier transform infra-red spectroscopy (FTIR) method detected trace levels (a few ppm) of amides (a possible degradation product of TiDG). In addition, up to 21 ± 4 micrograms of mercury per gram of solvent (or 17.5 μg/mL) was detected in this sample. There appears to be a possible correlation between the mercury level and the TiDG concentration in the solvent. The current gamma level (9.16 E4 dpm/mL) confirmed that the gamma concentration has returned to previous level where the process operated normally and as expected. The laboratory will continue to monitor the quality of the solvent in particular for any new impurities or degradation of the solvent components.« less
Design of coin sorter counter based on MCU
NASA Astrophysics Data System (ADS)
Yang, Yahan; Si, Xu
2018-04-01
With unmanned tickets, vending machines promotion, greatly increased the circulation of coins, especially bus companies, the financial sector need to classify a large number of coins every day, inventory, a huge workload. The design of the microcontroller as the control center, combined with the sensor technology and the corresponding mechanical structure to complete the separation of coins and finishing the packaging work and real-time monitoring and display of the type and number of coins function, this article details the system hardware and software design, and The test adjustment shows that the system can achieve the function of separating and sorting coins and monitoring the type and quantity of coins displayed on the coin.
Cheng, Jinbo; Liao, Yajin; Zhou, Lujun; Peng, Shengyi; Chen, Hong; Yuan, Zengqiang
2016-01-01
Type I interferon (IFN-I) is critical for a host against viral and bacterial infections via induction of hundreds of interferon-stimulated genes (ISGs), but the mechanism underlying the regulation of IFN-I remains largely unknown. In this study, we first demonstrate that ISG expression is required for optimal IFN-β levels, an effect that is further enhanced by endoplasmic reticulum (ER) stress. Furthermore, we identify mitochondrial calcium uniporter protein (MCU) as a mitochondrial antiviral signaling protein (MAVS)-interacting protein that is important for ER stress induction and amplified MAVS signaling activation. In addition, by performing an ectopic expression assay to screen a library of 117 human ISGs for effects on IFN-β levels, we found that tumor necrosis factor receptor 1 (TNFR1) significantly increases IFN-β levels independent of ER stress. Altogether, our findings suggest that MCU and TNFR1 are involved in the regulation of RIG-I-like receptors (RLR) signaling. PMID:26892273
Distributed Autonomous Control Action Based on Sensor and Mission Fusion
2005-09-01
programmable control algorithm driven by the readings of two pressure switch sensors located on either side of the valve unit. Thus, a micro-controller...and Characterization The process of leak detection and characterization must be accomplished with a set of pressure switch sensors. This sensor...economically supplementing existing widely used pressure switch type sensors which are characterized by prohibitively long inertial lag responses
USDA-ARS?s Scientific Manuscript database
Conifer control in sagebrush steppe of the western United States causes various levels of site disturbance influencing vegetation recovery and resource availability. The data presented in this article are growing season availability of soil micronutrients and levels of total soil carbon, organic ma...
NASA Astrophysics Data System (ADS)
Mihlan, G. I.; Mitchell, R. I.; Smith, R. K.
1984-07-01
A survey to assess control technology for integrated circuit fabrication was conducted. Engineering controls included local and general exhaust ventilation, shielding, and personal protective equipment. Devices or work stations that contained toxic materials that were potentially dangerous were controlled by local exhaust ventilation. Less hazardous areas were controlled by general exhaust ventilation. Process isolation was used in the plasma etching, low pressure chemical vapor deposition, and metallization operations. Shielding was used in ion implantation units to control X-ray emissions, in contact mask alignes to limit ultraviolet (UV) emissions, and in plasma etching units to control radiofrequency and UV emissions. Most operations were automated. Use of personal protective equipment varied by job function.
Factors Affecting the Discharge of Micro-Plastic Fibers from Household Laundry
NASA Astrophysics Data System (ADS)
Lange, N.
2017-12-01
Every day millions of loads of laundry are done in in the United States alone. Many, if not most, include synthetic fibers. During washing, micro-plastic fibers are released from the fabric, and discharged into the wastewater. These fibers have been detected in fresh water throughout the world and all of the oceans. These micro-plastic fibers are an emerging environmental contaminant that can adversely affect wildlife and are highly bio-accumulated in aquatic food-chains. Additionally, like other plastics, micro-fibers are not readily biodegraded and persist in the environment for a long time. In this research, I explored the effect of the way we wash clothes on the amount of micro-plastic fibers that are shed by common clothing materials containing man-made fibers. I collected discharge samples from wash and rinse cycles of a washing machine. I collected samples from a control wash using no detergent and then repeated five times. Next, I repeated the experiment five times using four different types of detergent. Large amounts of micro-plastic fibers were released during all wash cycles. However, the numbers decreased during the later rinse cycles. The use of laundry detergent increased the number of micro-plastic fibers released into the wash-water. Deep cleaning detergents produced over ten times more fibers than the no-detergent control. The gentlest detergent only released two times more fibers than the control. Therefore, it would be possible to affect the number of fibers released into the wastewater simply by selection of detergent. The ultimate goal of my research is to develop an optimized detergent that minimizes the number of micro-plastic fibers generated by washing and still effectively clean clothes.
NASA Astrophysics Data System (ADS)
Prinsloo, Gerro; Dobson, Robert; Brent, Alan; Mammoli, Andrea
2016-05-01
Concentrating solar power co-generation systems have been identified as potential stand-alone solar energy supply solutions in remote rural energy applications. This study describes the modelling and synthesis of a combined heat and power Stirling CSP system in order to evaluate its potential performance in small off-grid rural village applications in Africa. This Stirling micro-Combined Heat and Power (micro-CHP) system has a 1 kW electric capacity, with 3 kW of thermal generation capacity which is produced as waste heat recovered from the solar power generation process. As part of the development of an intelligent microgrid control and distribution solution, the Trinum micro-CHP system and other co-generation systems are systematically being modelled on the TRNSYS simulation platform. This paper describes the modelling and simulation of the Trinum micro-CHP configuration on TRNSYS as part of the process to develop the control automation solution for the smart rural microgrid in which the Trinum will serve as a solar powerpack. The results present simulated performance outputs for the Trinum micro-CHP system for a number of remote rural locations in Africa computed from real-time TRNSYS solar irradiation and weather data (yearly, monthly, daily) for the relevant locations. The focus of this paper is on the parametric modelling of the Trinum Stirling micro-CHP system, with specific reference to this system as a TRNSYS functional block in the microgrid simulation. The model is used to forecast the solar energy harvesting potential of the Trinum micro-CHP unit at a number of remote rural sites in Africa.
Development of an Inertial Measurement Unit for Unmanned Aerial Vehicles
2011-02-01
Tri-axis accelerometers Dual Angular rate gyros Micro-Controller board Battery Rubber isolation stands wireless comunication module (XBee...University. Special thanks to Mr. Jesse McAvoy & Mr. Laith Sahawneh for all the support and valuable scientific contributions. gxk gyk gzk gxb
DOE Office of Scientific and Technical Information (OSTI.GOV)
Poirier, M. R.; Burket, P. R.; Duignan, M. R.
2015-03-12
The Savannah River Site (SRS) is currently treating radioactive liquid waste with the Actinide Removal Process (ARP) and the Modular Caustic Side Solvent Extraction Unit (MCU). The low filter flux through the ARP has limited the rate at which radioactive liquid waste can be treated. Recent filter flux has averaged approximately 5 gallons per minute (gpm). Salt Batch 6 has had a lower processing rate and required frequent filter cleaning. Savannah River Remediation (SRR) has a desire to understand the causes of the low filter flux and to increase ARP/MCU throughput. In addition, at the time the testing started, SRRmore » was assessing the impact of replacing the 0.1 micron filter with a 0.5 micron filter. This report describes testing of MST filterability to investigate the impact of filter pore size and MST particle size on filter flux and testing of filter enhancers to attempt to increase filter flux. The authors constructed a laboratory-scale crossflow filter apparatus with two crossflow filters operating in parallel. One filter was a 0.1 micron Mott sintered SS filter and the other was a 0.5 micron Mott sintered SS filter. The authors also constructed a dead-end filtration apparatus to conduct screening tests with potential filter aids and body feeds, referred to as filter enhancers. The original baseline for ARP was 5.6 M sodium salt solution with a free hydroxide concentration of approximately 1.7 M.3 ARP has been operating with a sodium concentration of approximately 6.4 M and a free hydroxide concentration of approximately 2.5 M. SRNL conducted tests varying the concentration of sodium and free hydroxide to determine whether those changes had a significant effect on filter flux. The feed slurries for the MST filterability tests were composed of simple salts (NaOH, NaNO 2, and NaNO 3) and MST (0.2 – 4.8 g/L). The feed slurry for the filter enhancer tests contained simulated salt batch 6 supernate, MST, and filter enhancers.« less
Luyckx, K; Millet, S; Van Weyenberg, S; Herman, L; Heyndrickx, M; Dewulf, J; De Reu, K
2016-09-06
Colonisation of the environment of nursery units by pathogenic micro-organisms is an important factor in the persistence and spread of endemic diseases in pigs and zoonotic pathogens. These pathogens are generally controlled by the use of antibiotics and disinfectants. Since an increasing resistance against these measures has been reported in recent years, methods such as competitive exclusion (CE) are promoted as promising alternatives. This study showed that the infection pressure in CE units after microbial cleaning was not reduced to the same degree as in control units. Despite sufficient administration of probiotic-type spores, the analysed bacteria did not decrease in number after 3 production rounds in CE units, indicating no competitive exclusion. In addition, no differences in feed conversion were found between piglets raised in CE and control units in our study. Also, no differences in faecal consistency (indicator for enteric diseases) was noticed. These results indicate that the CE protocol is not a valuable alternative for classical C&D.
Effect of a multi-layer infection control barrier on the micro-hardness of a composite resin
HWANG, In-Nam; HONG, Sung-Ok; LEE, Bin-Na; HWANG, Yun-Chan; OH, Won-Mann; CHANG, Hoon-Sang
2012-01-01
Objective The aim of this study was to evaluate the effect of multiple layers of an infection control barrier on the micro-hardness of a composite resin. Material and Methods One, two, four, and eight layers of an infection control barrier were used to cover the light guides of a high-power light emitting diode (LED) light curing unit (LCU) and a low-power halogen LCU. The composite specimens were photopolymerized with the LCUs and the barriers, and the micro-hardness of the upper and lower surfaces was measured (n=10). The hardness ratio was calculated by dividing the bottom surface hardness of the experimental groups by the irradiated surface hardness of the control groups. The data was analyzed by two-way ANOVA and Tukey's HSD test. Results The micro-hardness of the composite specimens photopolymerized with the LED LCU decreased significantly in the four- and eight-layer groups of the upper surface and in the two-, four-, and eight-layer groups of the lower surface. The hardness ratio of the composite specimens was <80% in the eight-layer group. The micro-hardness of the composite specimens photopolymerized with the halogen LCU decreased significantly in the eight-layer group of the upper surface and in the two-, four-, and eight-layer groups of the lower surface. However, the hardness ratios of all the composite specimens photopolymerized with barriers were <80%. Conclusions The two-layer infection control barrier could be used on high-power LCUs without decreasing the surface hardness of the composite resin. However, when using an infection control barrier on the low-power LCUs, attention should be paid so as not to sacrifice the polymerization efficiency. PMID:23138746
Decentralized and Modular Electrical Architecture
NASA Astrophysics Data System (ADS)
Elisabelar, Christian; Lebaratoux, Laurence
2014-08-01
This paper presents the studies made on the definition and design of a decentralized and modular electrical architecture that can be used for power distribution, active thermal control (ATC), standard inputs-outputs electrical interfaces.Traditionally implemented inside central unit like OBC or RTU, these interfaces can be dispatched in the satellite by using MicroRTU.CNES propose a similar approach of MicroRTU. The system is based on a bus called BRIO (Bus Réparti des IO), which is composed, by a power bus and a RS485 digital bus. BRIO architecture is made with several miniature terminals called BTCU (BRIO Terminal Control Unit) distributed in the spacecraft.The challenge was to design and develop the BTCU with very little volume, low consumption and low cost. The standard BTCU models are developed and qualified with a configuration dedicated to ATC, while the first flight model will fly on MICROSCOPE for PYRO actuations and analogue acquisitions. The design of the BTCU is made in order to be easily adaptable for all type of electric interface needs.Extension of this concept is envisaged for power conditioning and distribution unit, and a Modular PCDU based on BRIO concept is proposed.
Micro-cogeneration units based on Stirling engine for heating and their real operation
NASA Astrophysics Data System (ADS)
Čierny, Jaroslav; Patsch, Marek
2014-08-01
This article was deal with micro-cogeneration units based on Stirling engine. We watched problematic of real working Stirling engine. The article also contain hookup of unit constructed at University of Zilina.
CFA-4 - a fluorinated metal-organic framework with exchangeable interchannel cations.
Fritzsche, J; Grzywa, M; Denysenko, D; Bon, V; Senkovska, I; Kaskel, S; Volkmer, D
2017-05-23
The syntheses and crystal structures of the fluorinated linker 1,4-bis(3,5-bis(trifluoromethyl)-1H-pyrazole-4-yl)benzene (H 2 -tfpb; 1) and the novel metal-organic framework family M[CFA-4] (Coordination Framework Augsburg University-4), M[Cu 5 (tfpb) 3 ] (M = Cu(i), K, Cs, Ca(0.5)), are described. The ligand 1 is fully characterized by single crystal X-ray diffraction, photoluminescence-, NMR-, IR spectroscopy, and mass spectrometry. The copper(i)-containing MOF crystallizes in the hexagonal crystal system within the chiral space group P6 3 22 (no. 182) and the unit cell parameters are as follows: a = 23.630(5) Å, c = 41.390(5) Å, V = 20 015(6) Å 3 . M[CFA-4] features a porous 3-D structure constructed from pentanuclear copper(i) secondary building units {Cu(pz) 6 } - (pz = pyrazolate). Cu(I)[CFA-4] is fully characterized by synchrotron single crystal X-ray diffraction, thermogravimetric analysis, variable temperature powder X-ray diffraction, IR spectroscopy, photoluminescence and gas sorption measurements. Moreover, thermal stability and gas sorption properties of K[CFA-4] and Cu(I)[CFA-4] are compared.
NASA Technical Reports Server (NTRS)
Yang, Ren; Feedback, Daniel L.; Wang, Wanjun
2004-01-01
This paper details a novel three-dimensional (3D) hydro-focusing micro cell sorter for micro flow cytometry applications. The unit was micro-fabricated by means of SU-8 3D lithography. The 3D microstructure for coaxial sheathing was designed, micro-fabricated, and tested. Three-dimensional hydrofocusing capability was demonstrated with an experiment to sort labeled tanned sheep erythrocytes (red blood cells). This polymer hydro-focusing microstructure is easily micro-fabricated and integrated with other polymer microfluidic structures.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-25
... UNITED STATES INSTITUTE OF PEACE Call for Proposals for a Micro Support Program on International Conflict Resolution and Peacebuilding For Immediate Release AGENCY: United States Institute of Peace. ACTION: Notice. SUMMARY: Micro Support Program on International Conflict Resolution and Peacebuilding...
Yu, Han; Zhai, Yongyan; Dai, Guoyong; Ru, Shi; Han, Sheng; Wei, Yongge
2017-10-09
Most state-of-art transition-metal catalysts usually require organic ligands, which are essential for controlling the reactivity and selectivity of reactions catalyzed by transition metals. However, organic ligands often suffer from severe problems including cost, toxicity, air/moisture sensitivity, and being commercially unavailable. Herein, we show a simple, mild, and efficient aerobic oxidation procedure of amines using inorganic ligand-supported non-precious metal catalysts 1, (NH 4 ) n [MMo 6 O 18 (OH) 6 ] (M=Cu 2+ ; Fe 3+ ; Co 3+ ; Ni 2+ ; Zn 2+ , n=3 or 4), synthesized by a simple one-step method in water at 100 °C, demonstrating that the catalytic activity and selectivity can be significantly improved by changing the central metal atom. In the presence of these catalysts, the catalytic oxidation of primary and secondary amines, as well as the coupling of alcohols and amines, can smoothly proceed to afford various imines with O 2 (1 atm) as the sole oxidant. In particular, the catalysts 1 have transition-metal ion core, and the planar arrangement of the six Mo VI centers at their highest oxidation states around the central heterometal can greatly enhance the Lewis acidity of catalytically active sites, and also enable the electrons in the center to delocalize onto the six edge-sharing MO 6 units, in the same way as ligands in traditional organometallic complexes. The versatility of this methodology maybe opens a path to catalytic oxidation through inorganic ligand-coordinated metal catalysis. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Single-Stage Step up/down Driver for Permanent-Magnet Synchronous Machines
NASA Astrophysics Data System (ADS)
Chen, T. R.; Juan, Y. L.; Huang, C. Y.; Kuo, C. T.
2017-11-01
The two-stage circuit composed of a step up/down dc converter and a three-phase voltage source inverter is usually adopted as the electric vehicle’s motor driver. The conventional topology is more complicated. Additional power loss resulted from twice power conversion would also cause lower efficiency. A single-stage step up/down Permanent-Magnet Synchronous Motor driver for Brushless DC (BLDC) Motor is proposed in this study. The number components and circuit complexity are reduced. The low frequency six-step square-wave control is used to reduce the switching losses. In the proposed topology, only one active switch is gated with a high frequency PWM signal for adjusting the rotation speed. The rotor position signals are fed back to calculate the motor speed for digital close-loop control in a MCU. A 600W prototype circuit is constructed to drive a BLDC motor with rated speed 3000 rpm, and can control the speed of six sections.
A Lab-on-Chip Design for Miniature Autonomous Bio-Chemoprospecting Planetary Rovers
NASA Astrophysics Data System (ADS)
Santoli, S.
The performance of the so-called ` Lab-on-Chip ' devices, featuring micrometre size components and employed at present for carrying out in a very fast and economic way the extremely high number of sequence determinations required in genomic analyses, can be largely improved as to further size reduction, decrease of power consumption and reaction efficiency through development of nanofluidics and of nano-to-micro inte- grated systems. As is shown, such new technologies would lead to robotic, fully autonomous, microwatt consumption and complete ` laboratory on a chip ' units for accurate, fast and cost-effective astrobiological and planetary exploration missions. The theory and the manufacturing technologies for the ` active chip ' of a miniature bio/chemoprospecting planetary rover working on micro- and nanofluidics are investigated. The chip would include micro- and nanoreactors, integrated MEMS (MicroElectroMechanical System) components, nanoelectronics and an intracavity nanolaser for highly accurate and fast chemical analysis as an application of such recently introduced solid state devices. Nano-reactors would be able to strongly speed up reaction kinetics as a result of increased frequency of reactive collisions. The reaction dynamics may also be altered with respect to standard macroscopic reactors. A built-in miniature telemetering unit would connect a network of other similar rovers and a central, ground-based or orbiting control unit for data collection and transmission to an Earth-based unit through a powerful antenna. The development of the ` Lab-on-Chip ' concept for space applications would affect the economy of space exploration missions, as the rover's ` Lab-on-Chip ' development would link space missions with the ever growing terrestrial market and business concerning such devices, largely employed in modern genomics and bioinformatics, so that it would allow the recoupment of space mission costs.
The survival of micro-organisms in space. Further rocket and balloon-borne exposure experiments.
Hotchin, J; Lorenz, P; Markusen, A; Hemenway, C
1967-01-01
This report describes the results of survival studies of terrestrial micro-organisms exposed directly to the space environment on two balloons and in two rocket flights. The work is part of a program to develop techniques for the collection of micro-organisms in the size range of micrometeorite particles in space or non-terrestrial atmospheres, and their return to earth in a viable state for further study. Previous survival studies were reported (J. Hotchin, P. Lorenz and C. Hemenway, Nature 206 (1965) 442) in which a few relatively large area samples of micro-organisms were exposed on millipore filter cemented to aluminum plates. In the present series of experiments, newly developed techniques have resulted in a 25-fold miniaturization resulting in a corresponding increase in the number of experiments performed. This has enabled a statistical evaluation of the results to be made. A total of 756 separate exposure units (each approximately 5 x 5 mm in size) were flown in four experiments, and organisms used were coliphage T1, penicillium roqueforti (THOM) mold spores, poliovirus type I (Pfizer attenuated Sabin vaccine strain), and bacillus subtilis spores. The organisms were deposited either by spraying directly upon the vinyl-coated metal units, or by droplet seeding into shallow depressions in the millipore filter membrane-coated units. Groups of units were prepared comprising fully exposed, inverted (screened by 2 mm of Al), and filter-protected organisms. All of these were included in the flight set, the back up set, and a laboratory control set. The altitude of the exposures varied from 35 km in the balloon experiments to 150 km in the rocket experiments. Times of exposures at altitude were approximately 6 hours for the balloon flights and about 3 minutes for the rocket experiments.
Thrust Generation with Low-Power Continuous-Wave Laser and Aluminum Foil Interaction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Horisawa, Hideyuki; Sumida, Sota; Funaki, Ikkoh
2010-05-06
The micro-newton thrust generation was observed through low-power continuous-wave laser and aluminum foil interaction without any remarkable ablation of the target surface. To evaluate the thrust characteristics, a torsion-balance thrust stand capable for the measurement of the thrust level down to micro-Newton ranges was developed. In the case of an aluminum foil target with 12.5 micrometer thickness, the maximum thrust level was 15 micro-newtons when the laser power was 20 W, or about 0.75 N/MW. It was also found that the laser intensity, or laser power per unit area, irradiated on the target was significantly important on the control ofmore » the thrust even under the low-intensity level.« less
An extensible, low-cost drifter control unit
NASA Astrophysics Data System (ADS)
Giudici, Andrea; Torsvik, Tomas; Soomere, Tarmo
2017-04-01
We introduce an extensible, low-cost drifter control unit, which is developed for use with surface drifters that are deployed in inland water bodies or near-coast regions. The control unit is custom-built on top of a small footprint micro controller. It makes use of a GPS receiver for position tracking, a GSM radio for data transmission, and two sensor buses to handle analog and digital data measured by an array of external sensors. A cloud-based data collection platform receives and stores the data transmitted over GPRS from the drifter. The control unit was found to perform satisfactorily in operational testing, providing data at sub-Hz frequency for position and temperature during extended time. Test deployments revealed some issues related to power consumption spikes. Even though the unit is fully functional in the present form and shows, on average, low energy consumption , battery packs with relatively large maximum output power are required to ensure its operation within prolonged periods of time. We expect that a further development of the power supply unit together with a careful de-synchronization scheme of sensors' operation would smooth those peaks without any loss of the quality of recorded information.
75 FR 53958 - Meeting of the Board of Visitors of Marine Corps University
Federal Register 2010, 2011, 2012, 2013, 2014
2010-09-02
... University AGENCY: Department of the Navy, DoD. ACTION: Notice of open meeting. SUMMARY: The Board of Visitors of the Marine Corps University (BOV MCU) will meet to review, develop and provide recommendations on all aspects of the academic and administrative policies of the University; examine all aspects of...
76 FR 12716 - Meeting of the Board of Visitors of Marine Corps University
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-08
... University AGENCY: Department of the Navy, DoD. ACTION: Notice of open meeting. SUMMARY: The Board of Visitors of the Marine Corps University (BOV MCU) will meet to review, develop and provide recommendations on all aspects of the academic and administrative policies of the University; examine all aspects of...
Engineered ascorbate peroxidase as a genetically encoded reporter for electron microscopy.
Martell, Jeffrey D; Deerinck, Thomas J; Sancak, Yasemin; Poulos, Thomas L; Mootha, Vamsi K; Sosinsky, Gina E; Ellisman, Mark H; Ting, Alice Y
2012-11-01
Electron microscopy (EM) is the standard method for imaging cellular structures with nanometer resolution, but existing genetic tags are inactive in most cellular compartments or require light and can be difficult to use. Here we report the development of 'APEX', a genetically encodable EM tag that is active in all cellular compartments and does not require light. APEX is a monomeric 28-kDa peroxidase that withstands strong EM fixation to give excellent ultrastructural preservation. We demonstrate the utility of APEX for high-resolution EM imaging of a variety of mammalian organelles and specific proteins using a simple and robust labeling procedure. We also fused APEX to the N or C terminus of the mitochondrial calcium uniporter (MCU), a recently identified channel whose topology is disputed. These fusions give EM contrast exclusively in the mitochondrial matrix, suggesting that both the N and C termini of MCU face the matrix. Because APEX staining is not dependent on light activation, APEX should make EM imaging of any cellular protein straightforward, regardless of the size or thickness of the specimen.
NASA Astrophysics Data System (ADS)
Willers, T.; Adroja, D. T.; Rainford, B. D.; Hu, Z.; Hollmann, N.; Körner, P. O.; Chin, Y.-Y.; Schmitz, D.; Hsieh, H. H.; Lin, H.-J.; Chen, C. T.; Bauer, E. D.; Sarrao, J. L.; McClellan, K. J.; Byler, D.; Geibel, C.; Steglich, F.; Aoki, H.; Lejay, P.; Tanaka, A.; Tjeng, L. H.; Severing, A.
2012-01-01
We have determined the ground-state wave functions and crystal-field-level schemes of CeRh2Si2 and CeRu2Si2 using linear polarized soft x-ray-absorption spectroscopy (XAS) and inelastic neutron scattering. We find large crystal-field splittings and ground-state wave functions which are made of mainly Jz = |±5/2> with some amount of |∓3/2> in both the compounds. The 4f0 contribution to the ground state of several members of the CeM2Si2 family with M=(Cu, Ru, Rh, Pd, and Au) has been determined with XAS, and the comparison reveals a trend concerning the delocalization of the f electrons. Absolute numbers are extracted from scaling to results from hard x-ray photoelectron spectroscopy on CeRu2Si2 by Yano [Phys. Rev. BPRBMDO1098-012110.1103/PhysRevB.77.035118 77, 035118 (2008)].
Huang, Changliang; Zhang, Hongye; Zhao, Yanfei; Chen, Sha; Liu, Zhimin
2012-11-15
Diatomite supported Pd-M (M=Cu, Co, Ni) bimetal nanocatalysts with various metal compositions were prepared and characterized by means of X-ray diffraction, transmission electron microscopy, and X-ray photoelectron spectroscopy. It was demonstrated that the metal nanoparticles were uniformly distributed on the support, and their size was centered around 8 nm with a relatively narrow size distribution. The catalysts were used to catalyze hydrogenation of long-chain aliphatic esters, including methyl palmitate, methyl stearate, and methyl laurate. It was indicated that the all diatomite-supported Pd-based bimetal catalysts were active to the selective hydrogenation of long-chain esters to corresponding alcohols at 270°C, originated from the synergistic effect between the metal particles and the diatomite support. For the selective hydrogenation of methyl palmitate, Pd-Cu/diatomite with metal loading of 1% and Pd/Cu=3 displayed the highest performance, giving a 1-hexadecanol yield of 82.9% at the substrate conversion of 98.8%. Copyright © 2012 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Chertkov, Yu B.; Disyuk, V. V.; Pimenov, E. Yu; Aksenova, N. V.
2017-01-01
Within the framework of research in possibility and prospects of power density equalization in boiling water reactors (as exemplified by WB-50) a work was undertaken to improve prior computational model of the WB-50 reactor implemented in MCU-RR software. Analysis of prior works showed that critical state calculations have deviation of calculated reactivity exceeding ±0.3 % (ΔKef/Kef) for minimum concentrations of boric acid in the reactor water and reaching 2 % for maximum concentration values. Axial coefficient of nonuniform burnup distribution reaches high values in the WB-50 reactor. Thus, the computational model needed refinement to take into account burnup inhomogeneity along the fuel assembly height. At this stage, computational results with mean square deviation of less than 0.7 % (ΔKef/Kef) and dispersion of design values of ±1 % (ΔK/K) shall be deemed acceptable. Further lowering of these parameters apparently requires root cause analysis of such large values and paying more attention to experimental measurement techniques.
Effect of simulated microgravity on oxidation-sensitive gene expression in PC12 cells
NASA Astrophysics Data System (ADS)
Kwon, Ohwon; Sartor, Maureen; Tomlinson, Craig R.; Millard, Ronald W.; Olah, Mark E.; Sankovic, John M.; Banerjee, Rupak K.
2006-01-01
Oxygen utilization by and oxygen dependence of cellular processes may be different in biological systems that are exposed to microgravity (micro-g). A baseline in which cellular changes in oxygen sensitive molecular processes occur during micro-g conditions would be important to pursue this question. The objective of this research is to analyze oxidation-sensitive gene expression in a model cell line [rat pheochromocytoma (PC12)] under simulated micro-g conditions. The PC12 cell line is well characterized in its response to oxygen, and is widely recognized as a sensitive model for studying the responses of oxygen-sensitive molecular and cellular processes. This study uses the rotating wall vessel bioreactor (RWV) designed at NASA to simulate micro-g. Gene expression in PC12 cells in response to micro-g was analyzed by DNA microarray technology. The microarray analysis of PC12 cells cultured for 4 days under simulated micro-g under standardized oxygen environment conditions revealed more than 100 genes whose expression levels were changed at least twofold (up-regulation of 65 genes and down-regulation of 39 genes) compared with those from cells in the unit gravity (unit-g) control. This study observed that genes involved in the oxidoreductase activity category were most significantly differentially expressed under micro-g conditions. Also, known oxidation-sensitive transcription factors such as hypoxia-inducible factor-2α, c-myc, and the peroxisome proliferator-activated receptor-γ were changed significantly. Our initial results from the gene expression microarray studies may provide a context in which to evaluate the effect of varying oxygen environments on the background of differential gene regulation of biological processes under variable gravity conditions.
Effect of simulated microgravity on oxidation-sensitive gene expression in PC12 cells
Kwon, Ohwon; Sartor, Maureen; Tomlinson, Craig R.; Millard, Ronald W.; Olah, Mark E.; Sankovic, John M.; Banerjee, Rupak K.
2008-01-01
Oxygen utilization by and oxygen dependence of cellular processes may be different in biological systems that are exposed to microgravity (micro-g). A baseline in which cellular changes in oxygen sensitive molecular processes occur during micro-g conditions would be important to pursue this question. The objective of this research is to analyze oxidation-sensitive gene expression in a model cell line [rat pheochromocytoma (PC12)] under simulated micro-g conditions. The PC12 cell line is well characterized in its response to oxygen, and is widely recognized as a sensitive model for studying the responses of oxygen-sensitive molecular and cellular processes. This study uses the rotating wall vessel bioreactor (RWV) designed at NASA to simulate micro-g. Gene expression in PC12 cells in response to micro-g was analyzed by DNA microarray technology. The microarray analysis of PC12 cells cultured for 4 days under simulated micro-g under standardized oxygen environment conditions revealed more than 100 genes whose expression levels were changed at least twofold (up-regulation of 65 genes and down-regulation of 39 genes) compared with those from cells in the unit gravity (unit-g) control. This study observed that genes involved in the oxidoreductase activity category were most significantly differentially expressed under micro-g conditions. Also, known oxidation-sensitive transcription factors such as hypoxia-inducible factor-2α, c-myc, and the peroxisome proliferator-activated receptor-γ were changed significantly. Our initial results from the gene expression microarray studies may provide a context in which to evaluate the effect of varying oxygen environments on the background of differential gene regulation of biological processes under variable gravity conditions. PMID:19081771
[Integrated Development of Full-automatic Fluorescence Analyzer].
Zhang, Mei; Lin, Zhibo; Yuan, Peng; Yao, Zhifeng; Hu, Yueming
2015-10-01
In view of the fact that medical inspection equipment sold in the domestic market is mainly imported from abroad and very expensive, we developed a full-automatic fluorescence analyzer in our center, presented in this paper. The present paper introduces the hardware architecture design of FPGA/DSP motion controlling card+PC+ STM32 embedded micro processing unit, software system based on C# multi thread, design and implementation of double-unit communication in detail. By simplifying the hardware structure, selecting hardware legitimately and adopting control system software to object-oriented technology, we have improved the precision and velocity of the control system significantly. Finally, the performance test showed that the control system could meet the needs of automated fluorescence analyzer on the functionality, performance and cost.
Validation of SMAP Surface Soil Moisture Products with Core Validation Sites
NASA Technical Reports Server (NTRS)
Colliander, A.; Jackson, T. J.; Bindlish, R.; Chan, S.; Das, N.; Kim, S. B.; Cosh, M. H.; Dunbar, R. S.; Dang, L.; Pashaian, L.;
2017-01-01
The NASA Soil Moisture Active Passive (SMAP) mission has utilized a set of core validation sites as the primary methodology in assessing the soil moisture retrieval algorithm performance. Those sites provide well calibrated in situ soil moisture measurements within SMAP product grid pixels for diverse conditions and locations.The estimation of the average soil moisture within the SMAP product grid pixels based on in situ measurements is more reliable when location specific calibration of the sensors has been performed and there is adequate replication over the spatial domain, with an up-scaling function based on analysis using independent estimates of the soil moisture distribution. SMAP fulfilled these requirements through a collaborative CalVal Partner program.This paper presents the results from 34 candidate core validation sites for the first eleven months of the SMAP mission. As a result of the screening of the sites prior to the availability of SMAP data, out of the 34 candidate sites 18 sites fulfilled all the requirements at one of the resolution scales (at least). The rest of the sites are used as secondary information in algorithm evaluation. The results indicate that the SMAP radiometer-based soil moisture data product meets its expected performance of 0.04 cu m/cu m volumetric soil moisture (unbiased root mean square error); the combined radar-radiometer product is close to its expected performance of 0.04 cu m/cu m, and the radar-based product meets its target accuracy of 0.06 cu m/cu m (the lengths of the combined and radar-based products are truncated to about 10 weeks because of the SMAP radar failure). Upon completing the intensive CalVal phase of the mission the SMAP project will continue to enhance the products in the primary and extended geographic domains, in co-operation with the CalVal Partners, by continuing the comparisons over the existing core validation sites and inclusion of candidate sites that can address shortcomings.
Pan, Yongwei; Hung, Leung-kim
2016-01-01
Purpose The terminal branches of the posterior interosseous nerve (PIN) are the main articular branch on the dorsal aspect of the wrist. Its relationship to dorsal wrist arthroscopic portals has not yet been elucidated. The purpose of this study was to quantitatively describe the anatomical relationships between the dorsal wrist arthroscopic portals and the PIN. Methods Dorsal wrist arthroscopic portals were established in 28 cadaver extremities, after which the limbs were dissected. Measurements were taken from the portals to the PIN. Results The PIN passed ulnar to the 3/4 portal with a mean distance of 4.8 mm (range: 1.2–12.0, standard deviation [SD] = 2.6). The PIN passed radial to the 4/5 portal with a mean interval of 9.0 mm (range: 3.8–12.7, SD = 2.3). The main trunk of PIN or its closest terminal branch was a mean of 7.2 mm (range: 0.0–13.2 mm, SD = 3.1) radial to the midcarpal radial (MCR) portal. In 2 of the 28 specimens, one terminal branch of PIN lay directly over this portal. The distance between the midcarpal ulnar (MCU) portal and the PIN or its closest terminal branch was only a mean of 1.6 mm (range: 0–6.4 mm, SD = 2.0). In 15 of the 28 specimens, the PIN lay directly over the MCU portal, or the portal was located between the terminal branches of PIN. Conclusion The MCU portal was the most precarious, due to the close proximity of PIN and its terminal branches. The 3/4 and MCR portals were also at risk, while the 4/5 portal was relatively safe for the PIN. PMID:27777824
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schwartz, Justin; Holmuhamedov, Ekhson; Zhang, Xun
Minocycline, a tetracycline-derived compound, mitigates damage caused by ischemia/reperfusion (I/R) injury. Here, 19 tetracycline-derived compounds were screened in comparison to minocycline for their ability to protect hepatocytes against damage from chemical hypoxia and I/R injury. Cultured rat hepatocytes were incubated with 50 μM of each tetracycline-derived compound 20 min prior to exposure to 500 μM iodoacetic acid plus 1 mM KCN (chemical hypoxia). In other experiments, hepatocytes were incubated in anoxic Krebs–Ringer–HEPES buffer at pH 6.2 for 4 h prior to reoxygenation at pH 7.4 (simulated I/R). Tetracycline-derived compounds were added 20 min prior to reperfusion. Ca{sup 2+} uptake wasmore » measured in isolated rat liver mitochondria incubated with Fluo-5N. Cell killing after 120 min of chemical hypoxia measured by propidium iodide (PI) fluorometry was 87%, which decreased to 28% and 42% with minocycline and doxycycline, respectively. After I/R, cell killing at 120 min decreased from 79% with vehicle to 43% and 49% with minocycline and doxycycline. No other tested compound decreased killing. Minocycline and doxycycline also inhibited mitochondrial Ca{sup 2+} uptake and suppressed the Ca{sup 2+}-induced mitochondrial permeability transition (MPT), the penultimate cause of cell death in reperfusion injury. Ru360, a specific inhibitor of the mitochondrial calcium uniporter (MCU), also decreased cell killing after hypoxia and I/R and blocked mitochondrial Ca{sup 2+} uptake and the MPT. Other proposed mechanisms, including mitochondrial depolarization and matrix metalloprotease inhibition, could not account for cytoprotection. Taken together, these results indicate that minocycline and doxycycline are cytoprotective by way of inhibition of MCU. - Highlights: • Minocycline and doxycycline are the only cytoprotective tetracyclines of those tested • Cytoprotective tetracyclines inhibit the MPT and mitochondrial calcium and iron uptake. • Cytoprotective tetracyclines protect by inhibiting the MCU.« less
Injection-depth-locking axial motion guided handheld micro-injector using CP-SSOCT.
Cheon, Gyeong Woo; Huang, Yong; Kwag, Hye Rin; Kim, Ki-Young; Taylor, Russell H; Gehlbach, Peter L; Kang, Jin U
2014-01-01
This paper presents a handheld micro-injector system using common-path swept source optical coherence tomography (CP-SSOCT) as a distal sensor with highly accurate injection-depth-locking. To achieve real-time, highly precise, and intuitive freehand control, the system used graphics processing unit (GPU) to process the oversampled OCT signal with high throughput and a smart customized motion monitoring control algorithm. A performance evaluation was conducted with 60-insertions and fluorescein dye injection tests to show how accurately the system can guide the needle and lock to the target depth. The evaluation tests show our system can guide the injection needle into the desired depth with 4.12 um average deviation error while injecting 50 nl of fluorescein dye.
LeBrun, Alexander; Joglekar, Tejashree; Bieberich, Charles; Ma, Ronghui; Zhu, Liang
2016-01-01
The objective of this study was to identify an injection strategy leading to repeatable nanoparticle deposition patterns in tumours and to quantify volumetric heat generation rate distribution based on micro-CT Hounsfield unit (HU) in magnetic nanoparticle hyperthermia. In vivo animal experiments were performed on graft prostatic cancer (PC3) tumours in immunodeficient mice to investigate whether lowering ferrofluid infusion rate improves control of the distribution of magnetic nanoparticles in tumour tissue. Nanoparticle distribution volume obtained from micro-CT scan was used to evaluate spreading of the nanoparticles from the injection site in tumours. Heating experiments were performed to quantify relationships among micro-CT HU values, local nanoparticle concentrations in the tumours, and the ferrofluid-induced volumetric heat generation rate (q(MNH)) when nanoparticles were subject to an alternating magnetic field. An infusion rate of 3 µL/min was identified to result in the most repeatable nanoparticle distribution in PC3 tumours. Linear relationships have been obtained to first convert micro-CT greyscale values to HU values, then to local nanoparticle concentrations, and finally to nanoparticle-induced q(MNH) values. The total energy deposition rate in tumours was calculated and the observed similarity in total energy deposition rates in all three infusion rate groups suggests improvement in minimising nanoparticle leakage from the tumours. The results of this study demonstrate that micro-CT generated q(MNH) distribution and tumour physical models improve predicting capability of heat transfer simulation for designing reliable treatment protocols using magnetic nanoparticle hyperthermia.
Oximeter reliability in a subzero environment.
Macnab, A J; Smith, M; Phillips, N; Smart, P
1996-11-01
Pulse oximeters optimize care in the pre-hospital setting. As British Columbia ambulance teams often provide care in subzero temperatures, we conducted a study to determine the reliability of 3 commercially-available portable oximeters in a subzero environment. We hypothesized that there is no significant difference between SaO2 readings obtained using a pulse oximeter at room temperature and a pulse oximeter operating at sub-zero temperatures. Subjects were stable normothermic children in intensive care on Hewlett Packard monitors (control unit) at room temperature. The test units were packed in dry ice in an insulated bin (temperature - 15 degrees C to -30 degrees C) and their sensors placed on the subjects, contralateral to the control sensors. Data were collected simultaneously from test and control units immediately following validation of control unit values by co-oximetry (blood gas). No data were unacceptable. Two units (Propaq 106EC and Nonin 8500N) functioned well to < -15 degrees C, providing data comparable to those obtained from the control unit (p < 0.001). The Siemens Micro O2 did not function at the temperatures tested. Monitor users who require equipment to function in subzero environments (military, Coast Guard, Mountain Rescue) should ensure that function is reliable, and could test units using this method.
Nondestructive Evaluation of Metallized Tape Bonds Formed by Tape Automated Bonding (TAB)
1989-04-01
powered by micro-positioning linear actuators. 3) Interchangeable sample-holding fixtures mounted upon top of slide assembly. 4) Coverslip gantry mounted...Controller Unit 1) Motor power supplies 2) Motor output servo driver amplifiers 3) "Macro-language" command Interpreter 4) Two-way cormunications with...adjustments are manual knobs giving approximately one degree of tilt adjustment per turn. The servo controller has self-contained power supplies for
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, T.
2016-02-23
Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 9 for the Interim Salt Disposition Program (ISDP). The Salt Batch 9 characterization results were previously reported. An Extraction-Scrub-Strip (ESS) test was performed to determine cesium distribution ratios (D (Cs)) and cesium concentration in the strip effluent and decontaminated salt solution (DSS) streams; this data will be used by Tank Farm Engineering to project a cesium decontamination factor (DF). This test used actual Tank 21H material, and a blend solvent prepared by SRNL that mimics the solvent composition currently being used atmore » the Modular Caustic-Side Solvent Extraction Unit (MCU). The ESS test showed acceptable performance with an extraction D (Cs) value of 52.4. This value is consistent with results from previous salt batch ESS tests using similar solvent formulations. This compares well against the predicted value of 56.5 from a recently created D (Cs) model« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, T. B.
Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Macrobatch (Salt Batch) 10 for the Interim Salt Disposition Program (ISDP). The Salt Batch 10 characterization results were previously reported.ii,iii An Extraction, -Scrub, -Strip (ESS) test was performed to determine cesium distribution ratios (D(Cs)) and cesium concentration in the strip effluent (SE) and decontaminated salt solution (DSS) streams; this data will be used by Tank Farm Engineering to project a cesium decontamination factor (DF). This test used actual Tank 21H material, and a sample of the NGS Blend solvent currently being used at the Modularmore » Caustic-Side Solvent Extraction Unit (MCU). The ESS test showed acceptable performance with an extraction D(Cs) value of 110. This value is consistent with results from previous salt batch ESS tests using similar solvent formulations. This is better than the predicted value of 39.8 from a recently created D(Cs) model.« less
ERIC Educational Resources Information Center
Canfield, Stephen L.; Ghafoor, Sheikh; Abdelrahman, Mohamed
2012-01-01
This paper describes the redesign and implementation of the course, "Introduction to Programming for Engineers" using microcontroller (MCU) hardware as the programming target. The objective of this effort is to improve the programming competency for engineering students by more closely relating the initial programming experience to the student's…
Anthropometry of a Fit Test Sample used in Evaluating the Current and Improved MCU-2/P Masks
1989-03-01
METHOD Forty-two head and face measurements were taken on each subject after he/she had completed MSA’s series of fit tests. Of these, 15 were measured...BREADTH Using spreading calipers, the hori- zontal distance between the fronto- temporale landmarks. 25 MEASUREMENT DESCRIPTIONS (cont’d) 13. NASAL
Communications Style Guide. Fourth Edition
2010-08-01
ethnography , phenomenological study , grounded theory study , and content analysis. You want to choose your research design based on your topic and how you...accessed 27 May 2008). 38 design or an historical research design. There are five basic types of qualitative research designs: case study ...suits the purpose of your study . Generally, while a student of MCU, you will use qualitative research
The Role of Design-of-Experiments in Managing Flow in Compact Air Vehicle Inlets
NASA Technical Reports Server (NTRS)
Anderson, Bernhard H.; Miller, Daniel N.; Gridley, Marvin C.; Agrell, Johan
2003-01-01
It is the purpose of this study to demonstrate the viability and economy of Design-of-Experiments methodologies to arrive at microscale secondary flow control array designs that maintain optimal inlet performance over a wide range of the mission variables and to explore how these statistical methods provide a better understanding of the management of flow in compact air vehicle inlets. These statistical design concepts were used to investigate the robustness properties of low unit strength micro-effector arrays. Low unit strength micro-effectors are micro-vanes set at very low angles-of-incidence with very long chord lengths. They were designed to influence the near wall inlet flow over an extended streamwise distance, and their advantage lies in low total pressure loss and high effectiveness in managing engine face distortion. The term robustness is used in this paper in the same sense as it is used in the industrial problem solving community. It refers to minimizing the effects of the hard-to-control factors that influence the development of a product or process. In Robustness Engineering, the effects of the hard-to-control factors are often called noise , and the hard-to-control factors themselves are referred to as the environmental variables or sometimes as the Taguchi noise variables. Hence Robust Optimization refers to minimizing the effects of the environmental or noise variables on the development (design) of a product or process. In the management of flow in compact inlets, the environmental or noise variables can be identified with the mission variables. Therefore this paper formulates a statistical design methodology that minimizes the impact of variations in the mission variables on inlet performance and demonstrates that these statistical design concepts can lead to simpler inlet flow management systems.
NASA Astrophysics Data System (ADS)
Perrot, Eddy; Boulanger, Damien; Christophe, Bruno; Foulon, Bernard; Liorzou, Françoise; Lebat, Vincent
2014-05-01
The GRACE FO mission, led by the JPL (Jet Propulsion Laboratory), is an Earth-orbiting gravity mission, continuation of the GRACE mission, that will produce an accurate model of the Earth's gravity field variation providing global climatic data during five year at least. The mission involves two satellites in a loosely controlled tandem formation, with a micro-wave link, and optionally a laser link, measuring the inter-satellites distance variation. Non-uniformities in the distribution of the Earth's mass cause the distance between the two satellites to vary. This variation is measured to recover gravity, after subtracting the non-gravitational contributors, as the residual drag. ONERA (the French Aerospace Lab) is developing, manufacturing and testing electrostatic accelerometers measuring this residual drag applied on the satellites. The accelerometer is composed of two main parts: the Sensor Unit (including the Sensor Unit Mechanics - SUM - and the Front-End Electronic Unit - FEEU) and the Interface Control Unit. In the Accelerometer Core, located in the Sensor Unit Mechanics, the proof mass is levitated and maintained in a center of an electrode cage by electrostatic forces. Thus, any drag acceleration applied on the satellite involves a variation on the servo-controlled electrostatic suspension of the mass. The voltage on the electrodes providing this electrostatic force is the measurement output of the accelerometer. The Preliminary Design Review was achieved successfully on November 2013. The FEEU Engineering Model is under test. Preliminary results on electronic unit will be compared with the expected performance. The integration of the SUM Engineering Model and the first ground levitation of the proof-mass will be presented. The impact of the accelerometer defaults (geometry, electronic and parasitic forces) leads to bias, misalignment and scale factor error, non-linearity and noise. Some of these accelerometer defaults are characterized by tests with micro-gravity pendulum bench and with drops in ZARM catapult. The post-processing needed to achieve the performance, in particular with regards to the temperature stability, will be explained.
Acute Radiation Sickness Amelioration Analysis
1994-05-01
Emetic Drugs 16. PRICE CODE Antagonists 17. SECURITY CLASSIFICATION 18. SECURITY CLASSIFICATION 19, SECURITY CLASSIFICATION 20. LIMITATION OF ABSTRACT OF...102 UNCLASSIFIED mcuIw IA IIIcaIIin or Isis PAW CLASSFIED BY: N/A since Unclassified. DECLASSIFY ON: N/A since Unclassified. SECURITY CLASSIFICATION OF...Approximately 2000 documents relevant to the development of the candidate anti-emetic drugs ondansetron (Zofran, Glaxo Pharmaceuticals) and granisetron
Automatic detection system of shaft part surface defect based on machine vision
NASA Astrophysics Data System (ADS)
Jiang, Lixing; Sun, Kuoyuan; Zhao, Fulai; Hao, Xiangyang
2015-05-01
Surface physical damage detection is an important part of the shaft parts quality inspection and the traditional detecting methods are mostly human eye identification which has many disadvantages such as low efficiency, bad reliability. In order to improve the automation level of the quality detection of shaft parts and establish its relevant industry quality standard, a machine vision inspection system connected with MCU was designed to realize the surface detection of shaft parts. The system adopt the monochrome line-scan digital camera and use the dark-field and forward illumination technology to acquire images with high contrast; the images were segmented to Bi-value images through maximum between-cluster variance method after image filtering and image enhancing algorithms; then the mainly contours were extracted based on the evaluation criterion of the aspect ratio and the area; then calculate the coordinates of the centre of gravity of defects area, namely locating point coordinates; At last, location of the defects area were marked by the coding pen communicated with MCU. Experiment show that no defect was omitted and false alarm error rate was lower than 5%, which showed that the designed system met the demand of shaft part on-line real-time detection.
A modular assembly method of a feed and thruster system for Cubesats
NASA Astrophysics Data System (ADS)
Louwerse, Marcus; Jansen, Henri; Elwenspoek, Miko
2010-11-01
A modular assembly method for devices based on micro system technology is presented. The assembly method forms the foundation for a miniaturized feed and thruster system as part of a micro propulsion unit working as a simple blow-down system of a rocket engine. The micro rocket is designed to be used for constellation maintenance of Cubesats, which measure 10 × 10 × 10 cm and have a mass less than 1 kg. The feed and thruster system contains an active valve, control electronics, a particle filter and an axisymmetric converging-diverging nozzle, all fabricated as separate modules. A novel method is used to integrate these modules by placing them on or in a glass tube package. The assembly method is shown to be a valid method but the valve module needs to be improved considerably.
Effects of ceftazidime, a betalactam antibiotic, on murine haemopoiesis in vitro.
Hauser, S P; Udupa, K B; Lipschitz, D A
1994-04-01
Agranulocytosis has been reported in 5-15% of patients treated with high-dose betalactam antibiotics (BLA). We investigated the toxic effect of ceftazidime (CEF) as a representative of these antibiotics on colony-forming unit-granulocyte/macrophage (CFU-GM), on burst-forming unit-erythroid (BFU-E) colony growth and on myelopoiesis in murine long-term bone marrow culture (mLTBMC). The CEF concentration resulting in a 50% inhibition of growth was 146 micrograms/ml (267 microM) for CFU-GM, 132 micrograms/ml (241 microM) for BFU-E and 180 micrograms/ml (329 microM) for myeloid cell production in the supernatant of mLTBMC. Following addition of CEF to mLTBMC, CFU-GM remained low for 1 week and total myeloid cell production remained low for 2 weeks after removal of CEF from culture. Thereafter the values returned to control levels. The myeloid differential counts in the supernatant and adherent layers demonstrated a 'maturation arrest', which could be overcome by simultaneously adding all-trans retinoic acid to culture. These results demonstrate that CEF has reversible inhibitory effects on myelopoiesis and highlight the utility of in vitro haemopoietic assays as models to examine drug-induced haemopoietic dyscrasias.
Ferrofluid based micro-electrical energy harvesting
NASA Astrophysics Data System (ADS)
Purohit, Viswas; Mazumder, Baishakhi; Jena, Grishma; Mishra, Madhusha; Materials Department, University of California, Santa Barbara, CA93106 Collaboration
2013-03-01
Innovations in energy harvesting have seen a quantum leap in the last decade. With the introduction of low energy devices in the market, micro energy harvesting units are being explored with much vigor. One of the recent areas of micro energy scavenging is the exploitation of existing vibrational energy and the use of various mechanical motions for the same, useful for low power consumption devices. Ferrofluids are liquids containing magnetic materials having nano-scale permanent magnetic dipoles. The present work explores the possibility of the use of this property for generation of electricity. Since the power generation is through a liquid material, it can take any shape as well as response to small acceleration levels. In this work, an electromagnet-based micropower generator is proposed to utilize the sloshing of the ferrofluid within a controlled chamber which moves to different low frequencies. As compared to permanent magnet units researched previously, ferrofluids can be placed in the smallest of containers of different shapes, thereby giving an output in response to the slightest change in motion. Mechanical motion from 1- 20 Hz was able to give an output voltage in mV's. In this paper, the efficiency and feasibility of such a system is demonstrated.
2012-12-16
sterilizing without causing toxicity in vivo. 1 Introduction As reported to the Centers for Disease Control and Pre- vention (CDC) between 2006 and...Owings MF. National Hospital Discharge Survey. Advance Data from Vital and Health Statistics. United States: Centers for Disease Control and Prevention...10.1007/s10856-012-4730-3. 19. Shirwaiker RA, Wysk RA, Kariyawasam S, Carrion H, Voigt RC. Micro-scale fabrication and characterization of a silver–polymer
Method and apparatus for actively controlling a micro-scale flexural plate wave device
Dohner, Jeffrey L.
2001-01-01
An actively controlled flexural plate wave device provides a micro-scale pump. A method of actively controlling a flexural plate wave device produces traveling waves in the device by coordinating the interaction of a magnetic field with actively controlled currents. An actively-controlled flexural plate wave device can be placed in a fluid channel and adapted for use as a micro-scale fluid pump to cool or drive micro-scale systems, for example, micro-chips, micro-electrical-mechanical devices, micro-fluid circuits, or micro-scale chemical analysis devices.
Draft Environmental Impact Statement (DEIS)
2000-07-01
MCB Marine Corps Base MCCDC Marine Corps Combat Development Center MCHC Marine Corps Heritage Center MCHMD Marine Corps History and Museum...other federal agencies. In addition to the MCU, the base is the site of the Marine Corps Officer Candidate School (OCS), the Marine Corps Combat ...at the Air-Ground Museum to support instruction and research on combat doctrine, tactics, and technology. The Air-Ground Museum also loans items to
Intelligent traffic lights based on MATLAB
NASA Astrophysics Data System (ADS)
Nie, Ying
2018-04-01
In this paper, I describes the traffic lights system and it has some. Through analysis, I used MATLAB technology, transformed the camera photographs into digital signals. Than divided the road vehicle is into three methods: very congestion, congestion, a little congestion. Through the MCU programming, solved the different roads have different delay time, and Used this method, saving time and resources, so as to reduce road congestion.
Summaries of Research; Fiscal Year 1987.
1988-02-01
field dentistry . PERSONNEL As of 30 September 1987, there were billets for 8 commissioned officers and 14 enlisted members. In addition there were 12...analysis; and research in the field of laboratory animal medicine and dentistry . The Clinical Investigations Department conducts research related to...MCU-2/P gas mask having a hose-attacheA’)canister system. Technical testing began and initial operational testing was completed. Ergonomic
Heavy-Ion Testing of the Freescale Qorivva 32-bit Automotive-Grade MCU
NASA Technical Reports Server (NTRS)
Wilcox, Ted; Seidleck, Christina; Casey, Megan; LaBel, Ken
2016-01-01
We present single-event effects testing results from a commercially-available automotive microcontroller. We discuss the difficulties encountered testing with commercially-provided evaluation boards while attempting to classify the complex and varied failure modes of a modern 32-bit microcontroller. This work also describes some of the possible advantages to using off-the-shelf automotive-grade electronics for low-risk aerospace applications.
Sharaf, Mahmoud S; Stevens, Don; Kamunde, Collins
2017-08-01
At excess levels, zinc (Zn) disrupts mitochondrial functional integrity and induces oxidative stress in aquatic organisms. Although much is known about the modulation of Zn toxicity by calcium (Ca) in fish, their interactions at the mitochondrial level have scarcely been investigated. Here we assessed the individual and combined effects of Zn and Ca on the relationship between mitochondrial respiration, ROS and membrane potential (ΔΨ mt ) in rainbow trout liver mitochondria. We tested if cation uptake through the mitochondrial calcium uniporter (MCU) is a prerequisite for Zn- and/or Ca-induced alteration of mitochondrial function. Furthermore, using our recently developed real-time multi-parametric method, we investigated the changes in respiration, ΔΨ mt , and reactive oxygen species (ROS, as hydrogen peroxide (H 2 O 2 )) release associated with Ca-induced mitochondrial depolarization imposed by transient and permanent openings of the mitochondrial permeability transition pore (mPTP). We found that independent of the MCU, Zn precipitated an immediate depolarization of the ΔΨ mt that was associated with relatively slow enhancement of H 2 O 2 release, inhibition of respiration and reversal of the positive correlation between ROS and ΔΨ mt . In contrast, an equitoxic dose of Ca caused transient depolarization, and stimulation of both respiration and H 2 O 2 release, effects that were completely abolished when the MCU was blocked. Contrary to our expectation that mitochondrial transition ROS Spike (mTRS) would be sensitive to both Zn and Ca, only Ca suppressed it. Moreover, Zn and Ca in combination immediately depolarized the ΔΨ mt , and caused transient and sustained stimulation of respiration and H 2 O 2 release, respectively. Lastly, we uncovered and characterized an mPTP-independent Ca-induced depolarization spike that was associated with exposure to moderately elevated levels of Ca. Importantly, we showed the stimulation of ROS release associated with highly elevated but not unrealistic Ca loads was not the cause but a result of mPTP opening in the high conductance mode. Copyright © 2017 Elsevier B.V. All rights reserved.
Design of an intelligent flight instrumentation unit using embedded RTOS
NASA Astrophysics Data System (ADS)
Estrada-Marmolejo, R.; García-Torales, G.; Torres-Ortega, H. H.; Flores, J. L.
2011-09-01
Micro Unmanned Aerial Vehicles (MUAV) must calculate its spatial position to control the flight dynamics, which is done by Inertial Measurement Units (IMUs). MEMS Inertial sensors have made possible to reduce the size and power consumption of such units. Commonly the flight instrumentation operates independently of the main processor. This work presents an instrumentation block design, which reduces size and power consumption of the complete system of a MUAV. This is done by coupling the inertial sensors to the main processor without considering any intermediate level of processing aside. Using Real Time Operating Systems (RTOS) reduces the number of intermediate components, increasing MUAV reliability. One advantage is the possibility to control several different sensors with a single communication bus. This feature of the MEMS sensors makes a smaller and less complex MUAV design possible.
Micro guidance and control technology overview
NASA Technical Reports Server (NTRS)
Kissel, Glen J.; Hadaegh, Fred Y.
1993-01-01
This paper gives an overview of micro-guidance and control technologies and in the process previews of the technology/user and systems issues presented in the guidance and control session at the workshop. We first present a discussion of the advantages of using micro-guidance and control components and then detail six micro-guidance and control thrusts that could have a revolutionary impact on space missions and systems. Specific technologies emerging in the micro-guidance and control field will be examined. These technologies fall into two broad categories: micro-attitude determination (inertial and celestial) and micro-actuation, control and sensing. Finally, the scope of the workshop's guidance and control panel are presented.
Micro-Masonry: Construction of 3D Structures by Mesoscale Self-Assembly
Fernandez, Javier G.; Khademhosseini, Ali
2010-01-01
A general method for construction of three dimensional structures by directed assembly of microscale polymeric sub-units is presented. Shape-controlled microgels are directed to assemble into different shapes by limiting their movement onto a molded substrate. The capillary forces, resulting from the presence of a liquid polymer, assemble the microgels in close contact with the rest of the units and with the free surface, the latter imposing the final geometry of the resulting construct. The result is a freestanding structure composed of one or multiple layers of sub-units assembled in a tightly packed conformation. The applicability of the technique for the construction of scaffolds with cell-laden sub-units is demonstrated. In addition, scaffolds formed by the sequential aggregation of sub-units are produced. PMID:20440697
Improvement of the Power Control Unit for Ion Thruster to Cope with Milli-Newton Range RIT
NASA Astrophysics Data System (ADS)
Ceruti, Luca; Polli, Aldo; Galantini, Paolo
2014-08-01
The recent development and testing activities of a miniaturized Radio-Frequency Ion Thruster, with relevant ancillary elements, in the range of 10 to 100 micro-Newtons, joined with past flight heritage in the milli-Newton range (RIT-10 for Artemis), shows an appealing capability of such an electrical propulsion technology to support thrust in a wide range of space applications from very fine attitude control up to deorbiting of small-medium satellites. As expectable, this implies that the mentioned ancillary elements (mainly Radio-Frequency Generator and Power Control Unit) require adaptation to the different requirements imposed to different missions and thrust ranges. Regarding the Power Control Unit different power levels, both the controllability requirements and the spacecraft interfaces impose non negligible adaptation leading to significant increase of development activities and associated cost (nonrecurring) increase. From that and with the main purpose to minimize such impacts and provide reliable equipments, Selex ES since a few years is devoting maximum attention in the incremental innovation of the existing design in order to maximize their reuse.
NASA Astrophysics Data System (ADS)
Perrot, Eddy; Boulanger, Damien; Christophe, Bruno; Foulon, Bernard; Liorzou, Françoise; Lebat, Vincent; Huynh, Phuong-Anh
2015-04-01
The GRACE FO mission, led by the JPL (Jet Propulsion Laboratory), is an Earth-orbiting gravity mission, continuation of the GRACE mission, which will produce an accurate model of the Earth's gravity field variation providing global climatic data during five years at least. The mission involves two satellites in a loosely controlled tandem formation, with a micro-wave link measuring the inter-satellites distance variation. Earth's mass distribution non-uniformities cause variations of the inter-satellite distance. This variation is measured to recover gravity, after subtracting the non-gravitational contributors, as the residual drag. ONERA (the French Aerospace Lab) is developing, manufacturing and testing electrostatic accelerometers measuring this residual drag applied on the satellites. The accelerometer is composed of two main parts: the Sensor Unit (including the Sensor Unit Mechanics - SUM - and the Front-End Electronic Unit - FEEU) and the Interface Control Unit - ICU. In the Accelerometer Core, located in the Sensor Unit Mechanics, the proof mass is levitated and maintained at the center of an electrode cage by electrostatic forces. Thus, any drag acceleration applied on the satellite involves a variation on the servo-controlled electrostatic suspension of the mass. The voltage on the electrodes providing this electrostatic force is the measurement output of the accelerometer. The impact of the accelerometer defaults (geometry, electronic and parasitic forces) leads to bias, misalignment and scale factor error, non-linearity and noise. Some of these accelerometer defaults are characterized by tests with micro-gravity pendulum bench on ground and with drops in ZARM catapult. The Critical Design Review was achieved successfully on September 2014. The Engineering Model (EM) was integrated and tested successfully, with ground levitation, drops, Electromagnetic Compatibility and thermal vacuum. The integration of the first Flight Model has begun on December 2014 and will be achieved on January 2015. The results of the Engineering Model tests and the status of the Flight Models will be presented.
NASA Astrophysics Data System (ADS)
Perrot, E.; Boulanger, D.; Christophe, B.; Foulon, B.; Lebat, V.; Huynh, P. A.; Liorzou, F.
2015-12-01
The GRACE FO mission, led by the JPL (Jet Propulsion Laboratory), is an Earth-orbiting gravity mission, continuation of the GRACE mission, which will produce an accurate model of the Earth's gravity field variation providing global climatic data during five years at least. The mission involves two satellites in a loosely controlled tandem formation, with a micro-wave link measuring the inter-satellites distance variation. Earth's mass distribution non-uniformities cause variations of the inter-satellite distance. This variation is measured to recover gravity, after subtracting the non-gravitational contributors, as the residual drag. ONERA (the French Aerospace Lab) is developing, manufacturing and testing electrostatic accelerometers measuring this residual drag applied on the satellites. The accelerometer is composed of two main parts: the Sensor Unit (including the Sensor Unit Mechanics - SUM - and the Front-End Electronic Unit - FEEU) and the Interface Control Unit - ICU. In the Accelerometer Core, located in the Sensor Unit Mechanics, the proof mass is levitated and maintained at the center of an electrode cage by electrostatic forces. Thus, any drag acceleration applied on the satellite involves a variation on the servo-controlled electrostatic suspension of the mass. The voltage on the electrodes providing this electrostatic force is the output measurement of the accelerometer. The impact of the accelerometer defaults (geometry, electronic and parasitic forces) leads to bias, misalignment and scale factor error, non-linearity and noise. Some of these accelerometer defaults are characterized by tests with micro-gravity pendulum bench on ground and with drops in ZARM catapult. The Critical Design Review was achieved successfully on September 2014. The Engineering Model (EM) was integrated and tested successfully, with ground levitation, drops, Electromagnetic Compatibility and thermal vacuum. The integration of the two Flight Models was done on July 2015. The tests will be achieved from July to November 2015. The results of the Engineering Model and Flight Models tests will be presented.
Yu, Yao; Yin, Sufeng; Kuan, Yi; Xu, Yingjun; Gao, Xuguang
2015-06-01
To describe the characteristics of airborne micro-organisms in the environment in a Chinese neurological intensive care unit (NICU). This prospective study monitored the air environment in two wards (large and small) of an NICU in a tertiary hospital in China for 12 months, using an LWC-1 centrifugal air sampler. Airborne micro-organisms were identified using standard microbiology techniques. The mean ± SD number of airborne bacteria was significantly higher in the large ward than in the small ward (200 ± 51 colony-forming units [CFU]/m(3) versus 110 ± 40 CFU/m(3), respectively). In the large ward only, the mean number of airborne bacteria in the autumn was significantly higher than in any of the other three seasons. A total of 279 airborne micro-organisms were identified (large ward: 195; small ward: 84). There was no significant difference in the type and distribution of airborne micro-organisms between the large and small wards. The majority of airborne micro-organisms were Gram-positive cocci in both wards. These findings suggest that the number of airborne micro-organisms was related to the number of patients on the NICU ward. © The Author(s) 2015 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
NASA Astrophysics Data System (ADS)
Elsayed, E. M.; Rashad, M. M.; Khalil, H. F. Y.; Ibrahim, I. A.; Hussein, M. R.; El-Sabbah, M. M. B.
2016-04-01
Nanocrystalline metal ferrite MFe2O4 (M=Cu, Zn, and Ni) thin films have been synthesized via electrodeposition-anodization process. Electrodeposited (M)Fe2 alloys were obtained from aqueous sulfate bath. The formed alloys were electrochemically oxidized (anodized) in aqueous (1 M KOH) solution, at room temperature, to the corresponding hydroxides. The parameters controlling the current efficiency of the electrodeposition of (M)Fe2 alloys such as the bath composition and the current density were studied and optimized. The anodized (M)Fe2 alloy films were annealed in air at 400 °C for 2 h. The results revealed the formation of three ferrite thin films were formed. The crystallite sizes of the produced films were in the range between 45 and 60 nm. The microstructure of the formed film was ferrite type dependent. The corrosion behavior of ferrite thin films in different pH solutions was investigated using open circuit potential (OCP) and potentiodynamic polarization measurements. The open circuit potential indicates that the initial potential E im of ZnFe2O4 thin films remained constant for a short time, then sharply increased in the less negative direction in acidic and alkaline medium compared with Ni and Cu ferrite films. The values of the corrosion current density I corr were higher for the ZnFe2O4 films at pH values of 1 and 12 compared with that of NiFe2O4 and CuFe2O4 which were higher only at pH value 1. The corrosion rate was very low for the three ferrite films when immersion in the neutral medium. The surface morphology recommended that Ni and Cu ferrite films were safely used in neutral and alkaline medium, whereas Zn ferrite film was only used in neutral atmospheres.
Effects of repeated exposure to 4-nonylphenol on the zooplankton community in littoral enclosures
DOE Office of Scientific and Technical Information (OSTI.GOV)
O`Halloran, S.L.; Liber, K.; Gangl, J.A.
1999-03-01
The effects of 4-nonylphenol (NP) on freshwater zooplankton were evaluated in 18 littoral enclosure mesocosms in northeastern Minnesota. The 18 enclosures were allocated to three blocks of six units with each block including two untreated control enclosures and one enclosure for each of four NP treatments. Treated enclosures received 11 applications of NP over a 20-d period between July 8 and 28, 1993. Maximum NP concentrations measured in the water column 2 h after each application averaged ({+-} SD) 5 {+-} 4, 23 {+-} 11, 76 {+-} 21, and 243 {+-} 41 {micro}g/L over the 11 applications. Nonylphenol dissipated rapidlymore » from the water column but was more persistent in sediments and in/on macrophytes. All cladoceran and copepod taxa were significantly reduced in abundance at 243 {+-} 41 {micro}g/L; some sensitive taxa were also affected by 76 {+-} 21 and 23 {+-} 11 {micro}g/L. While many rotifer taxa were unaffected at any of the test concentrations, several were affected at {ge} 76 {+-} 21 {micro}g/L. Ostracods were only affected at 2,243 {+-} 41 {micro}g/L. No zooplankton taxon was affected at 5 {+-} 4 {micro}g/L. The period of maximum impact usually occurred within 1 to 7 d of the last NP application, and recovery to control abundance levels generally occurred within 7 to 28 d of the last NP application. Two sensitive taxa, Acroperus and Calanoida, did not recover at {ge} 76 {+-} 21 {micro}g/L by the end of the study. The maximum acceptable toxicant concentration for protection of all zooplankton taxa was estimated at {approximately} 10 {micro}g/L, although overall community diversity was unaffected at 23 {+-} 11. The water was the most probable route of NP exposure, but the greater persistence of NP residues in/on macrophytes may have contributed to the lack of recovery of some macrophyte-associated taxa.« less
Numerical characterization of micro-cell UO2sbnd Mo pellet for enhanced thermal performance
NASA Astrophysics Data System (ADS)
Lee, Heung Soo; Kim, Dong-Joo; Kim, Sun Woo; Yang, Jae Ho; Koo, Yang-Hyun; Kim, Dong Rip
2016-08-01
Metallic micro-cell UO2 pellet with high thermal conductivity has received attention as a promising accident-tolerant fuel. Although experimental demonstrations have been successful, studies on the potency of current metallic micro-cell UO2 fuels for further enhancement of thermal performance are lacking. Here, we numerically investigated the thermal conductivities of micro-cell UO2sbnd Mo pellets in terms of the amount of Mo content, the unit cell size, and the aspect ratio of the micro-cells. The results showed good agreement with experimental measurements, and more importantly, indicated the importance of optimizing the unit cell geometries of the micro-cell pellets for greater increases in thermal conductivity. Consequently, the micro-cell UO2sbnd Mo pellets (5 vol% Mo) with modified geometries increased the thermal conductivity of the current UO2 pellets by about 2.5 times, and lowered the temperature gradient within the pellets by 62.9% under a linear heat generation rate of 200 W/cm.
High quantum yield of the Egyptian blue family of infrared phosphors (MCuSi4O10, M = Ca, Sr, Ba)
NASA Astrophysics Data System (ADS)
Berdahl, Paul; Boocock, Simon K.; Chan, George C.-Y.; Chen, Sharon S.; Levinson, Ronnen M.; Zalich, Michael A.
2018-05-01
The alkaline earth copper tetra-silicates, blue pigments, are interesting infrared phosphors. The Ca, Sr, and Ba variants fluoresce in the near-infrared (NIR) at 909, 914, and 948 nm, respectively, with spectral widths on the order of 120 nm. The highest quantum yield ϕ reported thus far is ca. 10%. We use temperature measurements in sunlight to determine this parameter. The yield depends on the pigment loading (mass per unit area) ω with values approaching 100% as ω → 0 for the Ca and Sr variants. Although maximum quantum yield occurs near ω = 0, maximum fluorescence occurs near ω = 70 g m-2, at which ϕ = 0.7. The better samples show fluorescence decay times in the range of 130 to 160 μs. The absorbing impurity CuO is often present. Good phosphor performance requires long fluorescence decay times and very low levels of parasitic absorption. The strong fluorescence enhances prospects for energy applications such as cooling of sunlit surfaces (to reduce air conditioning requirements) and luminescent solar concentrators.
Experimental Investigations And Numerical Modelling of 210CR12 Steel in Semi-Solid State
NASA Astrophysics Data System (ADS)
Macioł, Piotr; Zalecki, Władysław; Kuziak, Roman; Jakubowicz, Aleksandra; Weglarczyk, Stanisław
2011-05-01
Experimental investigation, including hot compression and simple closed die filling was performed. Temperature range of tests was between 1225 °C and 1320 °C. Temperature selection was adequate with liquid fraction between 20 and 60%, which is typical for thixoforming processes. In the die filling test, steel dies with ceramic layer was used (highly refractory air-setting mortar JM 3300 manufactured by Thermal Ceramics). Experiments were carried out on the Gleeble 3800 physical simulator with MCU unit. In the paper, methodology of experimental investigation is described. Dependency of forming forces on temperature and forming velocities is analysed. Obtained results are discussed. The second part of the paper concerns numerical modelling of semi-solid forming. Numerical models for both sets of test were developed. Structural and Computational Fluid Dynamics models are compared. Initial works in microstructural modelling of 210CR12 steel behaviour are described. Lattice Boltzman Method model for thixotropic flows is introduced. Microscale and macroscale models were integrated into multiscale simulation of semi-solid forming. Some fundamental issues related to multiscale modelling of thixoforming are discussed.
Bio-inspired multi-mode optic flow sensors for micro air vehicles
NASA Astrophysics Data System (ADS)
Park, Seokjun; Choi, Jaehyuk; Cho, Jihyun; Yoon, Euisik
2013-06-01
Monitoring wide-field surrounding information is essential for vision-based autonomous navigation in micro-air-vehicles (MAV). Our image-cube (iCube) module, which consists of multiple sensors that are facing different angles in 3-D space, can be applied to the wide-field of view optic flows estimation (μ-Compound eyes) and to attitude control (μ- Ocelli) in the Micro Autonomous Systems and Technology (MAST) platforms. In this paper, we report an analog/digital (A/D) mixed-mode optic-flow sensor, which generates both optic flows and normal images in different modes for μ- Compound eyes and μ-Ocelli applications. The sensor employs a time-stamp based optic flow algorithm which is modified from the conventional EMD (Elementary Motion Detector) algorithm to give an optimum partitioning of hardware blocks in analog and digital domains as well as adequate allocation of pixel-level, column-parallel, and chip-level signal processing. Temporal filtering, which may require huge hardware resources if implemented in digital domain, is remained in a pixel-level analog processing unit. The rest of the blocks, including feature detection and timestamp latching, are implemented using digital circuits in a column-parallel processing unit. Finally, time-stamp information is decoded into velocity from look-up tables, multiplications, and simple subtraction circuits in a chip-level processing unit, thus significantly reducing core digital processing power consumption. In the normal image mode, the sensor generates 8-b digital images using single slope ADCs in the column unit. In the optic flow mode, the sensor estimates 8-b 1-D optic flows from the integrated mixed-mode algorithm core and 2-D optic flows with an external timestamp processing, respectively.
ERIC Educational Resources Information Center
Hofer, Sarah I.; Schumacher, Ralph; Rubin, Herbert
2017-01-01
Background: Valid assessment of the understanding of Newton's mechanics is highly relevant to both physics classrooms and research. Several tests have been developed. What remains missing, however, is an efficient and fair test of conceptual understanding that is adapted to the content taught to secondary school students and that can be validly…
Neural networks for vertical microcode compaction
NASA Astrophysics Data System (ADS)
Chu, Pong P.
1992-09-01
Neural networks provide an alternative way to solve complex optimization problems. Instead of performing a program of instructions sequentially as in a traditional computer, neural network model explores many competing hypotheses simultaneously using its massively parallel net. The paper shows how to use the neural network approach to perform vertical micro-code compaction for a micro-programmed control unit. The compaction procedure includes two basic steps. The first step determines the compatibility classes and the second step selects a minimal subset to cover the control signals. Since the selection process is an NP- complete problem, to find an optimal solution is impractical. In this study, we employ a customized neural network to obtain the minimal subset. We first formalize this problem, and then define an `energy function' and map it to a two-layer fully connected neural network. The modified network has two types of neurons and can always obtain a valid solution.
High density pixel array and laser micro-milling method for fabricating array
NASA Technical Reports Server (NTRS)
McFall, James Earl (Inventor); Wiener-Avnear, Eliezer (Inventor)
2003-01-01
A pixel array device is fabricated by a laser micro-milling method under strict process control conditions. The device has an array of pixels bonded together with an adhesive filling the grooves between adjacent pixels. The array is fabricated by moving a substrate relative to a laser beam of predetermined intensity at a controlled, constant velocity along a predetermined path defining a set of grooves between adjacent pixels so that a predetermined laser flux per unit area is applied to the material, and repeating the movement for a plurality of passes of the laser beam until the grooves are ablated to a desired depth. The substrate is of an ultrasonic transducer material in one example for fabrication of a 2D ultrasonic phase array transducer. A substrate of phosphor material is used to fabricate an X-ray focal plane array detector.
Fabrication of micro metallic valve and pump
NASA Astrophysics Data System (ADS)
Yang, Ming; Kabasawa, Yasunari; Ito, Kuniyoshi
2010-03-01
Fabrication of micro devices by using micro metal forming was proposed by the authors. We developed a desktop servo-press machine with precise tooling system. Precise press forming processes including micro forging and micro joining has been carried out in a progressive die. In this study, micro metallic valve and pump were fabricated by using the precise press forming. The components are made of sheet metals, and assembled in to a unit in the progressive die. A micro check-valve with a diameter of 3mm and a length of 3.2mm was fabricated, and the property of flow resistance was evaluated. The results show that the check valve has high property of leakage proof. Since the valve is a unit parts with dimensions of several millimeters, it has advantage to be adapted to various pump design. Here, two kinds of micro pumps with the check-valves were fabricated. One is diaphragm pump actuated by vibration of the diaphragm, and another is tube-shaped pump actuated by resonation. The flow quantities of the pumps were evaluated and the results show that both of the pumps have high pumping performance.
Emerging Technologies for Assembly of Microscale Hydrogels
Kavaz, Doga; Demirel, Melik C.; Demirci, Utkan
2013-01-01
Assembly of cell encapsulating building blocks (i.e., microscale hydrogels) has significant applications in areas including regenerative medicine, tissue engineering, and cell-based in vitro assays for pharmaceutical research and drug discovery. Inspired by the repeating functional units observed in native tissues and biological systems (e.g., the lobule in liver, the nephron in kidney), assembly technologies aim to generate complex tissue structures by organizing microscale building blocks. Novel assembly technologies enable fabrication of engineered tissue constructs with controlled properties including tunable microarchitectural and predefined compositional features. Recent advances in micro- and nano-scale technologies have enabled engineering of microgel based three dimensional (3D) constructs. There is a need for high-throughput and scalable methods to assemble microscale units with a complex 3D micro-architecture. Emerging assembly methods include novel technologies based on microfluidics, acoustic and magnetic fields, nanotextured surfaces, and surface tension. In this review, we survey emerging microscale hydrogel assembly methods offering rapid, scalable microgel assembly in 3D, and provide future perspectives and discuss potential applications. PMID:23184717
The trend of digital control system design for nuclear power plants in Korea
DOE Office of Scientific and Technical Information (OSTI.GOV)
Park, S. H.; Jung, H. Y.; Yang, C. Y.
2006-07-01
Currently there are 20 nuclear power plants (NPPs) in operation, and 6 more units are under construction in Korea. The control systems of those NPPs have also been developed together with the technology advancement. Control systems started with On-Off control using the relay logic, had been evolved into Solid-State logic using TTL ICs, and applied with the micro-processors since the Yonggwang NPP Units 3 and 4 which started its construction in 1989. Multiplexers are also installed at the local plant areas to collect field input and to send output signals while communicating with the controllers located in the system cabinetsmore » near the main control room in order to reduce the field wiring cables. The design of the digital control system technology for the NPPs in Korea has been optimized to maximize the operability as well as the safety through the design, construction, start-up and operation experiences. Both Shin-Kori Units 1 and 2 and Shin-Wolsong Units 1 and 2 NPP projects under construction are being progressed at the same time. Digital Plant Control Systems of these projects have adopted multi-loop controllers, redundant loop configuration, and soft control system for the radwaste system. Programmable Logic Controller (PLC) and Distributed Control System (DCS) are applied with soft control system in Shin-Kori Units 3 and 4. This paper describes the evolvement of control system at the NPPs in Korea and the experience and design improvement through the observation of the latest failure of the digital control system. In addition, design concept and its trend of the digital control system being applied to the NPP in Korea are introduced. (authors)« less
Hu, Jiandong; Hu, Jingfang; Luo, Fukun; Li, Wei; Jiang, Guoliang; Li, Zhengfeng; Zhang, Runna
2009-03-15
An economical and high-performance bioanalyzer, with no use of laptop computer, based on the use of TSPR1k23 biosensors was systematically designed, and validated experimentally for its high performance. The analyzer is composed of a micro-flow cell, a thermoelectric cooler (TEC), a clamp, a touch-screen monitor, and an electronic control unit (ECU) incorporated with photoelectric conversion device. The micro-flow cell is made of stainless steel with high thermal conductivity, and the micro-flow system is based on PID temperature-controlled algorithm to keep the constant temperature (25 degrees C) of the liquid sample via thermal exchange with the clamp. With a peristaltic pump implemented by an injection loop flow system, the bioanalyzer allows the core sensor to be completely exposed to samples. The touch-screen monitor displays the normalized response signal values updated every 0.25s, with a typical noise level less than 5RU (response unit) within 2h. The bioanalyzer was validated using hepatitis B surface antigen (HBsAg) as an example. Anti-HBsAg monoclonal antibody is adhered to the surface of the sensor chip by a bifunctional cross-linker with the technology of self-assembly. The duration of the HBsAg measurement only lasts 5min with a dilution factor ranging from 200 to 1200, optimized with a R-squared value 0.998. The results suggested that the bioanalyzer has higher selectivity, lower cost, expanded detection limit, and shorter measuring time as compared with the HBsAg ELISA kit, especially for low concentrations of analyte.
A superior architecture of brightness enhancement for display backlighting
NASA Astrophysics Data System (ADS)
Dross, Oliver; Parkyn, William A.; Chaves, Julio; Falicoff, Waqidi; Miñano, Juan Carlos; Benitez, Pablo; Alvarez, Roberto
2006-08-01
Brightness enhancement of backlighting for displays is typically achieved via crossed micro prismatic films that are introduced between a backlight unit and a transmissive (LCD) display. Prismatic films let pass light only into a restricted angular range, while, in conjunction with other reflective elements below the backlight, all other light is recycled within the backlight unit, thereby increasing the backlight luminance. This design offers no free parameters to influence the resulting light distribution and suffers from insufficient stray light control. A novel strategy of light recycling is introduced, using a microlens array in conjunction with a hole array in a reflective surface, that can provide higher luminance, superior stray light control, and can be designed to meet almost any desired emission pattern. Similar strategies can be applied to mix light from different colored LEDs being mounted upside down to shine into a backlight unit.
In Vitro Comparative Study of Two Different Bleaching Agents on Micro-hardness Dental Enamel.
Fatima, Nazish; Ali Abidi, Syed Yawar; Meo, Ashraf Ali
2016-02-01
To evaluate the effect of home-use bleaching agent containing 16% Carbamide Peroxide (CP) and in-office bleaching agent containing 38% Hydrogen Peroxide (HP) on enamel micro-hardness. An in vitroexperimental study. Department of Operative Dentistry and Science of Dental Materials at Dr. Ishrat-ul-Ebad Khan Institute of Oral Health Sciences, Dow University of Health Sciences and Material Engineering Department of NED University of Engineering and Technology, Karachi, from July to December 2014. Atotal of 90 enamel slabs from 45 sound human 3rd molar were randomly divided into 3 groups. Each group contained 30 specimens (n=30). Group 1 was kept in artificial saliva at 37°C in incubator during the whole experiment. However, Groups 2 and 3 were treated with power whitening gel and tooth whitening pen respectively. After bleaching session, specimens were thoroughly rinsed with deionized water again for 10 seconds and then stored in artificial saliva at 37°C in incubator. Artificial saliva was changed after every 2 days. The Vickers hardness tester (Wolpert 402 MVD, Germany) was adjusted to a load of 0.1 kg (100 gm) and dwell time of 5 seconds. Three Vickers were performed on each specimen using a hardness tester according to the ISO 6507-3:1998 specification. Micro-hardness measurements were performed before and after bleaching at day 1, 7 and 14. In the control group, the baseline micro-hardness was 181.1 ±9.3 which was reduced after the storage on day 1, 7 and 14 (p = 0.104). In Group 2, baseline micro-hardness was 180.4 ±10.1 which was reduced to 179.79 ±10.0 units after day 1. Whereas, on day 7 and 14, the values of micro-hardness were 179.8 ±10 and 179.7 ±10.29, respectively (p=0.091). Furthermore, the baseline micro-hardness in Group 3 was 174.0 ±22.9 units which was reduced to 173 ±23 on day 1, 170 ±30 on day 7 and 173 ±23 on day 14 (p = 0.256). The statistically insignificant difference was found among micro-hardness values of different bleaching agents (p = 0.118). Bleaching with 38% Hydrogen Peroxide (HP) and 16% Carbamide Peroxide (CP) resulted in insignificant effect on surface micro-hardness of enamel.
Kuniansky, Eve L.; Bellino, Jason C.
2012-04-19
A goal of the U.S. Geological Survey Groundwater Resources Program is to assess the availability of fresh water within each of the principal aquifers in the United States with the greatest groundwater withdrawals. The Floridan aquifer system (FAS), which covers an area of approximately 100,000 square miles in Florida and parts of Georgia, Alabama, Mississippi, and South Carolina, is one such principal aquifer, having the fifth largest groundwater withdrawals in the Nation, totaling 3.64 billion gallons per day in 2000. Compilation of FAS hydraulic properties is critical to the development and calibration of groundwater flow models that can be used to develop water budgets spatially and temporally, as well as to evaluate resource changes over time. Wells with aquifer test data were identified as Upper Floridan aquifer (UFA), Lower Floridan aquifer (LFA), Floridan aquifer system (FAS, Upper Floridan with some middle and/or Lower Floridan), or middle Floridan confining unit (MCU), based on the identification from the original database or report description, or comparison of the open interval of the well with previously published maps.This report consolidates aquifer hydraulic property data obtained from multiple databases and reports of the U.S. Geological Survey, various State agencies, and the Water Management Districts of Florida, that are compiled into tables to provide a single information source for transmissivity and storage properties of the FAS as of October 2011. Transmissivity calculated from aquifer pumping tests and specific-capacity data are included. Values for transmissivity and storage coefficients are intended for use in regional or sub regional groundwater flow models; thus, any tests (aquifer pumping tests and specific capacity data) that were conducted with packers or for open intervals less than 30 feet in length are excluded from the summary statistics and tables of this report, but are included in the database.The transmissivity distribution from the aquifer pumping tests is highly variable. The transmissivity based on aquifer pumping tests (from 1,045 values for the UFA and FAS) ranges from 8 to about 9,300,000 square feet per day (ft2/d) and values of storage coefficient (646 reported) range from 3x10-9 to 0.41. The 64 transmissivity values for the LFA range from about 130 to 4,500,000 ft2/d, and the 17 storage coefficient values range from 7x10-8 to 0.03. The 14 transmissivity values for the MCU range from 1 to about 600,000 ft2/d and the 10 storage coefficient values range from 8x10-8 to 0.03. Transmissivity estimates for the UFA and FAS for 442 specific capacity tests range from approximately 200 to 1,000,000 ft2/d.
A robust adaptive load frequency control for micro-grids.
Khooban, Mohammad-Hassan; Niknam, Taher; Blaabjerg, Frede; Davari, Pooya; Dragicevic, Tomislav
2016-11-01
The goal of this study is to introduce a novel robust load frequency control (LFC) strategy for micro-grid(s) (MG(s)) in islanded mode operation. Admittedly, power generators in MG(s) cannot supply steady electric power output and sometimes cause unbalance between supply and demand. Battery energy storage system (BESS) is one of the effective solutions to these problems. Due to the high cost of the BESS, a new idea of Vehicle-to-Grid (V2G) is that a battery of Electric-Vehicle (EV) can be applied as a tantamount large-scale BESS in MG(s). As a result, a new robust control strategy for an islanded micro-grid (MG) is introduced that can consider electric vehicles׳ (EV(s)) effect. Moreover, in this paper, a new combination of the General Type II Fuzzy Logic Sets (GT2FLS) and the Modified Harmony Search Algorithm (MHSA) technique is applied for adaptive tuning of proportional-integral (PI) controller. Implementing General Type II Fuzzy Systems is computationally expensive. However, using a recently introduced α-plane representation, GT2FLS can be seen as a composition of several Interval Type II Fuzzy Logic Systems (IT2FLS) with a corresponding level of α for each. Real-data from an offshore wind farm in Sweden and solar radiation data in Aberdeen (United Kingdom) was used in order to examine the performance of the proposed novel controller. A comparison is made between the achieved results of Optimal Fuzzy-PI (OFPI) controller and those of Optimal Interval Type II Fuzzy-PI (IT2FPI) controller, which are of most recent advances in the area at hand. The Simulation results prove the successfulness and effectiveness of the proposed controller. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.
Design of PH sensor signal acquisition and display system
NASA Astrophysics Data System (ADS)
Qian, Huifa; Zhang, Quanzhu; Deng, Yonghong
2017-06-01
With the continuous development of sensor manufacturing technology, how to better deal with the signal is particularly important. PH value of the sensor voltage generated by the signal as a signal, through the MCU acquisition A / D conversion, and ultimately through the digital display of its PH value. The system uses hardware and software to achieve the results obtained with the high-precision PH meter to strive to improve the accuracy and reduce error.
Mechanics of additively manufactured porous biomaterials based on the rhombicuboctahedron unit cell.
Hedayati, R; Sadighi, M; Mohammadi-Aghdam, M; Zadpoor, A A
2016-01-01
Thanks to recent developments in additive manufacturing techniques, it is now possible to fabricate porous biomaterials with arbitrarily complex micro-architectures. Micro-architectures of such biomaterials determine their physical and biological properties, meaning that one could potentially improve the performance of such biomaterials through rational design of micro-architecture. The relationship between the micro-architecture of porous biomaterials and their physical and biological properties has therefore received increasing attention recently. In this paper, we studied the mechanical properties of porous biomaterials made from a relatively unexplored unit cell, namely rhombicuboctahedron. We derived analytical relationships that relate the micro-architecture of such porous biomaterials, i.e. the dimensions of the rhombicuboctahedron unit cell, to their elastic modulus, Poisson's ratio, and yield stress. Finite element models were also developed to validate the analytical solutions. Analytical and numerical results were compared with experimental data from one of our recent studies. It was found that analytical solutions and numerical results show a very good agreement particularly for smaller values of apparent density. The elastic moduli predicted by analytical and numerical models were in very good agreement with experimental observations too. While in excellent agreement with each other, analytical and numerical models somewhat over-predicted the yield stress of the porous structures as compared to experimental data. As the ratio of the vertical struts to the inclined struts, α, approaches zero and infinity, the rhombicuboctahedron unit cell respectively approaches the octahedron (or truncated cube) and cube unit cells. For those limits, the analytical solutions presented here were found to approach the analytic solutions obtained for the octahedron, truncated cube, and cube unit cells, meaning that the presented solutions are generalizations of the analytical solutions obtained for several other types of porous biomaterials. Copyright © 2015 Elsevier Ltd. All rights reserved.
Hedefalk, Finn; Svensson, Patrick; Harrie, Lars
2017-01-01
This paper presents datasets that enable historical longitudinal studies of micro-level geographic factors in a rural setting. These types of datasets are new, as historical demography studies have generally failed to properly include the micro-level geographic factors. Our datasets describe the geography over five Swedish rural parishes, and by linking them to a longitudinal demographic database, we obtain a geocoded population (at the property unit level) for this area for the period 1813–1914. The population is a subset of the Scanian Economic Demographic Database (SEDD). The geographic information includes the following feature types: property units, wetlands, buildings, roads and railroads. The property units and wetlands are stored in object-lifeline time representations (information about creation, changes and ends of objects are recorded in time), whereas the other feature types are stored as snapshots in time. Thus, the datasets present one of the first opportunities to study historical spatio-temporal patterns at the micro-level. PMID:28398288
Ezra, Elishai; Maor, Idan; Bavli, Danny; Shalom, Itai; Levy, Gahl; Prill, Sebastian; Jaeger, Magnus S; Nahmias, Yaakov
2015-08-01
Microfluidic applications range from combinatorial synthesis to high throughput screening, with platforms integrating analog perfusion components, digitally controlled micro-valves and a range of sensors that demand a variety of communication protocols. Currently, discrete control units are used to regulate and monitor each component, resulting in scattered control interfaces that limit data integration and synchronization. Here, we present a microprocessor-based control unit, utilizing the MS Gadgeteer open framework that integrates all aspects of microfluidics through a high-current electronic circuit that supports and synchronizes digital and analog signals for perfusion components, pressure elements, and arbitrary sensor communication protocols using a plug-and-play interface. The control unit supports an integrated touch screen and TCP/IP interface that provides local and remote control of flow and data acquisition. To establish the ability of our control unit to integrate and synchronize complex microfluidic circuits we developed an equi-pressure combinatorial mixer. We demonstrate the generation of complex perfusion sequences, allowing the automated sampling, washing, and calibrating of an electrochemical lactate sensor continuously monitoring hepatocyte viability following exposure to the pesticide rotenone. Importantly, integration of an optical sensor allowed us to implement automated optimization protocols that require different computational challenges including: prioritized data structures in a genetic algorithm, distributed computational efforts in multiple-hill climbing searches and real-time realization of probabilistic models in simulated annealing. Our system offers a comprehensive solution for establishing optimization protocols and perfusion sequences in complex microfluidic circuits.
Comfort, Alison; Leegwater, Anthony; Nakhimovsky, Sharon; Kansembe, Henry; Hamainza, Busiku; Bwalya, Benson; Alilio, Martin; Johns, Ben; Olsho, Lauren
2017-01-04
Country-level evidence on the impact of malaria control on micro-economic outcomes is vital for mobilizing domestic and donor resources for malaria control. Using routinely available survey data could facilitate this investigation in a cost-efficient way. The authors used Malaria Indicator Surveys (MIS) and Living Conditions Monitoring Survey (LCMS) data from 2006 to 2010 for all 72 districts in Zambia to relate malaria control scale-up with household food spending (proxy for household well-being), educational attainment and agricultural production. The authors used two quasi-experimental designs: (1) a generalized propensity score for a continuous treatment variable (defined as coverage from owning insecticide-treated bed nets and/or receipt of indoor residual spraying); and, (2) a district fixed effects model to assess changes in the outcome relative to changes in treatment pre-post scale-up. The unit of analysis was at district level. The authors also conducted simulations post-analysis to assess statistical power. Micro-economic outcomes increased (33% increase in food spending) concurrently with malaria control coverage (62% increase) from 2006 to 2010. Despite using data from all 72 districts, both analytic methods yielded wide confidence intervals that do not conclusively link outcomes and malaria control coverage increases. The authors cannot rule out positive, null or negative effects. The upper bound estimates of the results show that if malaria control coverage increases from 60 to 70%, food spending could increase up to 14%, maize production could increase up to 57%, and years of schooling could increase up to 0.5 years. Simulations indicated that the generalized propensity score model did not have good statistical power. While it is technically possible to use routinely available survey data to relate malaria control scale-up and micro-economic outcomes, it is not clear from this analysis that meaningful results can be obtained when survey data are highly aggregated. Researchers in similar settings should assess the feasibility of disaggregating existing survey data. Additionally, large surveys, such as LCMS and MIS, could incorporate data on both malaria coverage and household expenditures, respectively.
MAGI: a Node.js web service for fast microRNA-Seq analysis in a GPU infrastructure.
Kim, Jihoon; Levy, Eric; Ferbrache, Alex; Stepanowsky, Petra; Farcas, Claudiu; Wang, Shuang; Brunner, Stefan; Bath, Tyler; Wu, Yuan; Ohno-Machado, Lucila
2014-10-01
MAGI is a web service for fast MicroRNA-Seq data analysis in a graphics processing unit (GPU) infrastructure. Using just a browser, users have access to results as web reports in just a few hours->600% end-to-end performance improvement over state of the art. MAGI's salient features are (i) transfer of large input files in native FASTA with Qualities (FASTQ) format through drag-and-drop operations, (ii) rapid prediction of microRNA target genes leveraging parallel computing with GPU devices, (iii) all-in-one analytics with novel feature extraction, statistical test for differential expression and diagnostic plot generation for quality control and (iv) interactive visualization and exploration of results in web reports that are readily available for publication. MAGI relies on the Node.js JavaScript framework, along with NVIDIA CUDA C, PHP: Hypertext Preprocessor (PHP), Perl and R. It is freely available at http://magi.ucsd.edu. © The Author 2014. Published by Oxford University Press.
2004-02-01
Andy Jenkins, an engineer for the Lab on a Chip Applications Development program, helped build the Applications Development Unit (ADU-25), a one-of-a-kind facility for controlling and analyzing processes on chips with extreme accuracy. Pressure is used to cause fluids to travel through network of fluid pathways, or micro-channels, embossed on the chips through a process similar to the one used to print circuits on computer chips. To make customized chips for various applications, NASA has an agreement with the U.S. Army's Micro devices and Micro fabrication Laboratory at Redstone Arsenal in Huntsville, Alabama, where NASA's Marshall Space Flight Center (MSFC) is located. The Marshall Center team is also collaborating with scientists at other NASA centers and at universities to develop custom chip designs for many applications, such as studying how fluidic systems work in spacecraft and identifying microbes in self-contained life support systems. Chips could even be designed for use on Earth, such as for detecting deadly microbes in heating and air systems. (NASA/MSFC/D.Stoffer)
Podsiad, Amy; Standiford, Theodore J; Ballinger, Megan N; Eakin, Richard; Park, Pauline; Kunkel, Steven L; Moore, Bethany B; Bhan, Urvashi
2016-03-01
Postinfluenza bacterial pneumonia is associated with significant mortality and morbidity. MicroRNAs (miRNAs) are small, noncoding RNAs that regulate gene expression posttranscriptionally. miR-155 has recently emerged as a crucial regulator of innate immunity and inflammatory responses and is induced in macrophages during infection. We hypothesized upregulation of miR-155 inhibits IL-17 and increases susceptibility to secondary bacterial pneumonia. Mice were challenged with 100 plaque-forming units H1N1 intranasally and were infected with 10(7) colony-forming units of MRSA intratracheally at day 5 postviral challenge. Lungs were harvested 24 h later, and expression of miR-155, IL-17, and IL-23 was measured by real-time RT-PCR. Induction of miR-155 was 3.6-fold higher in dual-infected lungs compared with single infection. miR-155(-/-) mice were protected with significantly lower (4-fold) bacterial burden and no differences in viral load, associated with robust induction of IL-23 and IL-17 (2.2- and 4.8-fold, respectively) postsequential challenge with virus and bacteria, compared with WT mice. Treatment with miR-155 antagomir improved lung bacterial clearance by 4.2-fold compared with control antagomir postsequential infection with virus and bacteria. Moreover, lung macrophages collected from patients with postviral bacterial pneumonia also had upregulation of miR-155 expression compared with healthy controls, consistent with observations in our murine model. This is the first demonstration that cellular miRNAs regulate postinfluenza immune response to subsequent bacterial challenge by suppressing the IL-17 pathway in the lung. Our findings suggest that antagonizing certain microRNA might serve as a potential therapeutic strategy against secondary bacterial infection. Copyright © 2016 the American Physiological Society.
Dynamic Control System Mode Performance of the Space Technology-7 Disturbance Reduction System
NASA Technical Reports Server (NTRS)
O'Donnell, James R., Jr.; Hsu, Oscar; Maghami, Peiman
2017-01-01
The Space Technology-7 (ST-7) Disturbance Reduction System (DRS) is an experiment package aboard the European Space Agency (ESA) LISA Pathfinder spacecraft, launched on December 3, 2015. DRS consists of three primary components: Colloidal MicroNewton Thrusters (CMNTs), an Integrated Avionics Unit (IAU), and flight-software implementing the Command and Data Handling (C&DH) and Dynamic Control System (DCS) algorithms. The CMNTs were designed to provide thrust from 5 to 30 micro Newton, with thrust controllability and resolution of 0.1 micro Newton and thrust noise of 0.1 micro Newton/(square root of (Hz)) in the measurement band from 1-30 mHz. The IAU hosts the C&DH and DCS flight software, as well as interfaces with both the CMNT electronics and the LISA Pathfinder spacecraft. When in control, the DCS uses star tracker attitude data and capacitive or optically-measured position and attitude information from LISA Pathfinder and the LISA Technology Package (LTP) to control the attitude and position of the spacecraft and the two test masses inside the LTP. After completion of the nominal ESA LISA Pathfinder mission, the DRS experiment was commissioned followed by its nominal mission. DRS operations extended over the next five months, interspersed with station keeping, anomaly resolution, and periods where control was handed back to LISA Pathfinder for them to conduct further experiments. The primary DRS mission ended on December 6, 2016, with the experiment meeting all of its Level 1 requirements. The DCS, developed at the NASA Goddard Space Flight Center, consists of five spacecraft control modes and six test mass control modes, combined into six 'DRS Mission Modes'. Attitude Control and Zero-G were primarily used to control the spacecraft during initial handover and during many of the CMNT characterization experiments. The other Mission Modes, Drag Free Low Force, 18-DOF Transitional, and 18-DOF, were used to provide drag-free control of the spacecraft about the test masses. This paper will discuss the performance of these DCS spacecraft and test mass control modes. Flight data will be shown from each mode throughout the mission, both from nominal operations and during various flight experiments. The DCS team also made some changes to controller, filter, and limit parameters during operations; the motivation and results of these changes will be shown and discussed.
China in Africa: America’s Soft Power Challenge
2011-05-01
22 MCU/CSC/Merrill, T.E./ A Y11 BffiLIOGRAPHY Bergsten, C. Fred, Bates Gill, Nicholas R. Lardy, and Derek Mitchell. China: The Balance Sheet: What...Tiyambe Zeleza. "Africa." World Book Advanced. World Book, 2011. Web. 5 Mar. 2011. Eisenman, Joshua, Eric Heginbotham, and Derek Mitchell, eds. China...docLib/20070726 WhatAfricomMeansforAfrica.pdf. Nye, JosephS. Bound to Lead: The Changing Nature of American Power. New York: Basic Books, 1990. Ong
Advanced Mail Systems Scanner Technology. Executive Summary and Appendixes A-E.
1980-10-01
data base. 6. Perform color acquisition studies. 7. Investigate address and bar code reading. MASS MEMORY TECHNOLOGY 1. Collect performance data on...area of the 1728-by-2200 ICAS image memory and to transmit the data to any of the three color memories of the Comtal. Function table information can...for printing color images. The software allows the transmission of data from the ICAS frame-store memory via the MCU to the Dicomed. Software test
Development and Validation of The SMAP Enhanced Passive Soil Moisture Product
NASA Technical Reports Server (NTRS)
Chan, S.; Bindlish, R.; O'Neill, P.; Jackson, T.; Chaubell, J.; Piepmeier, J.; Dunbar, S.; Colliander, A.; Chen, F.; Entekhabi, D.;
2017-01-01
Since the beginning of its routine science operation in March 2015, the NASA SMAP observatory has been returning interference-mitigated brightness temperature observations at L-band (1.41 GHz) frequency from space. The resulting data enable frequent global mapping of soil moisture with a retrieval uncertainty below 0.040 cu m/cu m at a 36 km spatial scale. This paper describes the development and validation of an enhanced version of the current standard soil moisture product. Compared with the standard product that is posted on a 36 km grid, the new enhanced product is posted on a 9 km grid. Derived from the same time-ordered brightness temperature observations that feed the current standard passive soil moisture product, the enhanced passive soil moisture product leverages on the Backus-Gilbert optimal interpolation technique that more fully utilizes the additional information from the original radiometer observations to achieve global mapping of soil moisture with enhanced clarity. The resulting enhanced soil moisture product was assessed using long-term in situ soil moisture observations from core validation sites located in diverse biomes and was found to exhibit an average retrieval uncertainty below 0.040 cu m/cu m. As of December 2016, the enhanced soil moisture product has been made available to the public from the NASA Distributed Active Archive Center at the National Snow and Ice Data Center.
NASA Astrophysics Data System (ADS)
Sakakima, Hiroshi; Nishitani, Mikihiko; Yamamoto, Koichi; Wada, Takahiro
2015-08-01
BaCuSeF and related compounds, MCuQF (M = Ba, Sr; Q = Se, S), are known to show p-type conduction. The formation energies of the Cu vacancy ΔH[VCu] in a MCuQF system were computed by first-principles calculation with a generalized gradient approximation (GGA) of the Perdew-Burke-Ernzerhof (PBE) functional as an electron exchange and correlation functional. The density of states (DOS) of BaCuSeF was calculated with the hybrid functional of Heyd-Scuseria-Ernzerhof (HSE) 06. ΔH[VCu] was found to be very small under both the Cu- and Q-rich conditions, which probably contributes to p-type conduction. The electronic structure of BaCuSeF was studied by X-ray photoelectron spectroscopy (XPS) with UV photoelectron yield spectroscopy (UVPYS) and photoemission yield spectroscopy (PYS). The determined depth of the top of the valence band relative to the vacuum level was about 4.9 eV. This value is desirable for applications in compound semiconductor thin-film tandem solar cells since the absorbers of polycrystalline thin-film solar cells, such as CdTe and Cu(In,Ga)Se2, are p-type semiconductors. The DOS of BaCuSeF calculated with the HSE06 functional was almost consistent with the XPS spectrum.
Lee, Andre; Vastermark, Ake; Saier, Milton H
2014-08-01
Mitochondrial calcium uniporters (MCUs) (TC no. 1.A.77) are oligomeric channel proteins found in the mitochondrial inner membrane. MCUs have two well-conserved transmembrane segments (TMSs), connected by a linker, similar to bacterial MCU homologues. These proteins and chlamydial IncA proteins (of unknown function; TC no. 9.B.159) are homologous to prokaryotic Mg(2+) transporters, AtpI and AtpZ, based on comparison scores of up to 14.5 sds. A phylogenetic tree containing all of these proteins showed that the AtpZ proteins cluster coherently as a subset within the large and diverse AtpI cluster, which branches separately from the MCUs and IncAs, both of which cluster coherently. The MCUs and AtpZs share the same two TMS topology, but the AtpIs have four TMSs, and IncAs can have either two (most frequent) or four (less frequent) TMSs. Binary alignments, comparison scores and motif analyses showed that TMSs 1 and 2 align with TMSs 3 and 4 of the AtpIs, suggesting that the four TMS AtpI proteins arose via an intragenic duplication event. These findings establish an evolutionary link interconnecting eukaryotic and prokaryotic Ca(2+) and Mg(2+) transporters with chlamydial IncAs, and lead us to suggest that all members of the MCU superfamily, including IncAs, function as divalent cation channels. © 2014 The Authors.
Lee, Andre; Vastermark, Ake
2014-01-01
Mitochondrial calcium uniporters (MCUs) (TC no. 1.A.77) are oligomeric channel proteins found in the mitochondrial inner membrane. MCUs have two well-conserved transmembrane segments (TMSs), connected by a linker, similar to bacterial MCU homologues. These proteins and chlamydial IncA proteins (of unknown function; TC no. 9.B.159) are homologous to prokaryotic Mg2+ transporters, AtpI and AtpZ, based on comparison scores of up to 14.5 sds. A phylogenetic tree containing all of these proteins showed that the AtpZ proteins cluster coherently as a subset within the large and diverse AtpI cluster, which branches separately from the MCUs and IncAs, both of which cluster coherently. The MCUs and AtpZs share the same two TMS topology, but the AtpIs have four TMSs, and IncAs can have either two (most frequent) or four (less frequent) TMSs. Binary alignments, comparison scores and motif analyses showed that TMSs 1 and 2 align with TMSs 3 and 4 of the AtpIs, suggesting that the four TMS AtpI proteins arose via an intragenic duplication event. These findings establish an evolutionary link interconnecting eukaryotic and prokaryotic Ca2+ and Mg2+ transporters with chlamydial IncAs, and lead us to suggest that all members of the MCU superfamily, including IncAs, function as divalent cation channels. PMID:24869855
NASA Astrophysics Data System (ADS)
Lebat, V.; Boulanger, D.; Christophe, B.; Foulon, B.; Liorzou, F.; Perrot, E.; Huynh, P. A.
2014-12-01
The GRACE FO mission, led by the JPL (Jet Propulsion Laboratory), is an Earth-orbiting gravity mission, continuation of the GRACE mission, which will produce an accurate model of the Earth's gravity field variation providing global climatic data during five years at least. The mission involves two satellites in a loosely controlled tandem formation, with a micro-wave link measuring the inter-satellites distance variation. Earth's mass distribution non-uniformities cause variations of the inter-satellite distance. This variation is measured to recover gravity, after subtracting the non-gravitational contributors, as the residual drag. ONERA (the French Aerospace Lab) is developing, manufacturing and testing electrostatic accelerometers measuring this residual drag applied on the satellites. The accelerometer is composed of two main parts: the Sensor Unit (including the Sensor Unit Mechanics - SUM - and the Front-End Electronic Unit - FEEU) and the Interface Control Unit - ICU. In the Accelerometer Core, located in the Sensor Unit Mechanics, the proof mass is levitated and maintained at the center of an electrode cage by electrostatic forces. Thus, any drag acceleration applied on the satellite involves a variation on the servo-controlled electrostatic suspension of the mass. The voltage on the electrodes providing this electrostatic force is the measurement output of the accelerometer. The impact of the accelerometer defaults (geometry, electronic and parasitic forces) leads to bias, misalignment and scale factor error, non-linearity and noise. Some of these accelerometer defaults are characterized by tests with micro-gravity pendulum bench on ground and with drops in ZARM catapult. The Preliminary Design Review was achieved successfully on November 2013. The Engineering Model (EM) was integrated successfully and is under test, with ground levitation, drops, Electromagnetic Compatibility and thermal vacuum. The complete EM tests will be achieved on October 2014. The Critical Design Review is scheduled at the end of September 2014, and the integration of the first Flight Model will begin on October 2014. The results of the Engineering Model tests and the status of the Flight Models will be presented.
Qu, Jingyuan; Kadic, Muamer; Naber, Andreas; Wegener, Martin
2017-01-01
Controlling the thermal expansion of materials is of great technological importance. Uncontrolled thermal expansion can lead to failure or irreversible destruction of structures and devices. In ordinary crystals, thermal expansion is governed by the asymmetry of the microscopic binding potential, which cannot be adjusted easily. In artificial crystals called metamaterials, thermal expansion can be controlled by structure. Here, following previous theoretical work, we fabricate three-dimensional (3D) two-component polymer micro-lattices by using gray-tone laser lithography. We perform cross-correlation analysis of optical microscopy images taken at different sample temperatures. The derived displacement-vector field reveals that the thermal expansion and resulting bending of the bi-material beams leads to a rotation of the 3D chiral crosses arranged onto a 3D checkerboard pattern within one metamaterial unit cell. These rotations can compensate the expansion of the all positive constituents, leading to an effectively near-zero thermal length-expansion coefficient, or over-compensate the expansion, leading to an effectively negative thermal length-expansion coefficient. This evidences a striking level of thermal-expansion control. PMID:28079161
NASA Astrophysics Data System (ADS)
Okada, Hironao; Kobayashi, Takeshi; Masuda, Takashi; Itoh, Toshihiro
2009-07-01
We describe a low power consumption wireless sensor node designed for monitoring the conditions of animals, especially of chickens. The node detects variations in 24-h behavior patterns by acquiring the number of the movement of an animal whose acceleration exceeds a threshold measured in per unit time. Wireless sensor nodes when operated intermittently are likely to miss necessary data during their sleep mode state and waste the power in the case of acquiring useless data. We design the node worked only when required acceleration is detected using a piezoelectric accelerometer and a comparator for wake-up source of micro controller unit.
Diode step stress program for JANTX1N5615
NASA Technical Reports Server (NTRS)
1979-01-01
The effect of power/temperature step stress when applied to the switching diode JANTX1N5615 manufactured by Semtech and Micro semiconductor was examined. A total of 48 samples from each manufacturer were submitted to the process. In addition, two control sample units were maintained for verification of the electrical parametric testing. All test samples were subjected to the electrical tests after completing the prior power/temperature step stress point. Results are presented.
United States Air Force Research Initiation Program for 1988. Volume 2
1990-04-01
Specialty: Modeling and Simulation ENGINEERING AND SERVICES CENTER (Tyndall Air Force Base) Dr. Wayne A. Charlie Dr. Peter Jeffers (1987) Colorado State...Michael Sydor University of New Hampshire University of Minnesota Specialty: Systems Modeling & Controls Specialty: Optics, Material Science Dr. John...9MG-025 4 Modeling and Simulation on Micro- Dr. Joseph J. Feeley (1987) computers, 1989 760-7MG-070 5 Two Dimensional MHD Simulation of Dr. Manuel A
Controlling measures of micro-plastic and nano pollutants: A short review of disposing waste toners.
Ruan, Jujun; Qin, Baojia; Huang, Jiaxin
2018-05-31
Micro-plastic and nano-particle have been the focal pollutants in environmental science. The printer toner is omitted micro-plastic and nano pollutant. It is comprised of micro polyacrylate styrene and nano-Fe 3 O 4 particles. Polyacrylate styrene and nano-metal were proved to be irreversibly toxic to biological cells. Therefore, toners have the potential environmental risk and healthy harm due to include micro plastics and nano-metal. To our knowledge, few studies provided the specific collection and treatment of micro-plastic pollutant. This paper has chosen a kind of micro-plastic and nano pollutant toxic toner and provided technical guidance and inspiration for controlling the micro-plastic and nano pollutants. The method of vacuum-gasification-condensation was adopted for controlling the micro-plastic and nano pollutant toner. We believe this review will open up a potential avenue for controlling micro-plastic and nano pollutants for environmental protection. Copyright © 2018 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Su, Yaorong
Although impressive progress has been made in improving the performance of organic thin film transistors (OTFTs), the high operation voltage resulting from the low gate areal capacitance of traditional SiO 2 remains a severe limitation that hinders OTFTs' development in practical applications. In this regard, developing new materials with high- k characteristics at low cost is of great scientific and technological importance in the area of both academia and industry. In this thesis, we first describe a simple solution-based method to fabricate a high-k bilayer Al2Oy/TiOx (ATO) dielectric system at low temperature. Then the dielectric properties of the ATO are characterized and discussed in detail. Furthermore, by employing the high-k ATO as gate dielectric, low-voltage copper phthalocyanine (CuPc) based OTFTs are successfully developed. Interestingly, the obtained low-voltage CuPc TFT exhibits outstanding electrical performance, which is even higher than the device fabricated on traditional low-k SiO2. The above results seem to be contradictory to the reported results due to the fact that high-k usually shows adverse effect on the device performance. This abnormal phenomenon is then studied in detail. Characterization on the initial growth shows that the CuPc molecules assemble in a "rod-like" nano crystal with interconnected network on ATO, which probably promotes the charge carrier transport, whereas, they form isolated small islands with amorphous structure on SiO2. In addition, a better metal/organic contact is observed on ATO, which benefits the charge carrier injection. Our studies suggest that the low-temperature, solution-processed high-k ATO is a promising candidate for fabrication of high-performance, low-voltage OTFTs. Furthermore, it is well known that the properties of the dielectric/semiconductor and electrode/semiconductor interfaces are crucial in controlling the electrical properties of OTFTs. Hence, investigation the effects of interfaces engineering on improving the electrical characteristics of OTFTs is of great technological importance. For the dielectric/semiconductor interface, an octadecylphosphonic acid (ODPA) self-assembled monolayer (SAM) is used to modify the surface of ATO (ODPA/ATO). For the electrode/semiconductor interface, a simple in-situ modified Cu (M-Cu) is employed as source-drain (S/D) electrodes in stead of commonly used Au. The electrical characteristics of pentacene TFT are drastically enhanced upon interfaces modification. Moreover, by encapsulating the M-Cu with a thin layer of Au (Au/ M-Cu), the device performance is further improved. The detailed mechanism is systematically explored. Finally, organic electronic devices on flexible plastic substrates have attracted much attention due to their low-cost, rollability, large-area processability, and so on. One of the most critical issues in realization flexible OTFTs is the integration of gate dielectrics with flexible substrates. We have successfully incorporated the ODPA/ATO with Au coated flexible polyimide (PI) substrate. By using Au/M-Cu as S/D electrode, the flexible pentacene TFTs show outstanding electrical performance. In addition, the mechanical flexibility and reliability of the devices are studied in detail. Our approach demonstrates an effective way to realize low-cost, high-performance flexible OTFTs.
Studying neighborhood crime across different macro spatial scales: The case of robbery in 4 cities.
Hipp, John R; Wo, James C; Kim, Young-An
2017-11-01
Whereas there is a burgeoning literature focusing on the spatial distribution of crime events across neighborhoods or micro-geographic units in a specific city, the present study expands this line of research by selecting four cities that vary across two macro-spatial dimensions: population in the micro-environment, and population in the broader macro-environment. We assess the relationship between measures constructed at different spatial scales and robbery rates in blocks in four cities: 1) San Francisco (high in micro- and macro-environment population); 2) Honolulu (high in micro- but low in macro-environment population); 3) Los Angeles (low in micro- but high in macro-environment population); 4) Sacramento (low in micro- and macro-environment population). Whereas the socio-demographic characteristics of residents further than ½ mile away do not impact robbery rates, the number of people up to 2.5 miles away are related to robbery rates, especially in the two cities with smaller micro-environment population, implying a larger spatial scale than is often considered. The results show that coefficient estimates differ somewhat more between cities differing in micro-environment population compared to those differing based on macro-environment population. It is therefore necessary to consider the broader macro-environment even when focusing on the level of crime across neighborhoods or micro-geographic units within an area. Copyright © 2017 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Germain, Shawn St.; Thomas, Kenneth; Farris, Ronald
2014-09-01
The long-term viability of existing nuclear power plants (NPPs) in the United States (U.S.) is dependent upon a number of factors, including maintaining high capacity factors, maintaining nuclear safety, and reducing operating costs, particularly those associated with refueling outages. Refueling outages typically take 20-30 days, and for existing light water NPPs in the U.S., the reactor cannot be in operation during the outage. Furthermore, given that many NPPs generate between $1-1.5 million/day in revenue when in operation, there is considerable interest in shortening the length of refueling outages. Yet, refueling outages are highly complex operations, involving multiple concurrent and dependentmore » activities that are difficult to coordinate. Finding ways to improve refueling outage performance while maintaining nuclear safety has proven to be difficult. The Advanced Outage Control Center project is a research and development (R&D) demonstration activity under the Light Water Reactor Sustainability (LWRS) Program. LWRS is a R&D program which works with industry R&D programs to establish technical foundations for the licensing and managing of long-term, safe, and economical operation of current NPPs. The Advanced Outage Control Center project has the goal of improving the management of commercial NPP refueling outages. To accomplish this goal, this INL R&D project is developing an advanced outage control center (OCC) that is specifically designed to maximize the usefulness of communication and collaboration technologies for outage coordination and problem resolution activities. This report describes specific recent efforts to develop a capability called outage Micro-Scheduling. Micro-Scheduling is the ability to allocate and schedule outage support task resources on a sub-hour basis. Micro-Scheduling is the real-time fine-tuning of the outage schedule to react to the actual progress of the primary outage activities to ensure that support task resources are optimally deployed with the least amount of delay and unproductive use of resources. The remaining sections of this report describe in more detail the scheduling challenges that occur during outages, how a Micro-Scheduling capability helps address those challenges, and provides a status update on work accomplished to date and the path forward.« less
Kiuru, H J
2001-01-01
This paper gives a brief description of the development of dissolved air flotation DAF (or so-called high pressure flotation) as an unit operation for removal of solids in water and wastewater treatment during the last 80 years up to this time. The first DAF-systems used in the water industry were the ADKA and Sveen-Pedersen ones from the 1920s. Some of these are still in use. The tanks in which the flotation phenomenon takes place in these systems are very shallow and narrow as well as rather long. The flow rate of water is some 2-3 m/h (at most less than 5 m/h only) and there is a very thin micro-bubble blanket below the water surface between the dry sludge blanket on that and the clarified water which flows almost horizontally below the bubble blanket toward the end of the tanks to be taken out there from near the bottom. The second generation of DAF was introduced in the 1960s and these units are widely in use today. Their tanks are almost square ones having usually a little bit more length than breadth. They are rather deep, too. There is an under-flow wall in front of the back wall of the units having a narrow horizontal gap on the bottom of the tanks for letting out the clarified water from the flotation space. The flow rate of water is usually 5-7 m/h or at most less than 10 m/h. The direction of flow is 30-45 degrees below the horizontal. There is a rather thick micro-bubble bed at the beginning of the tank below the dry sludge blanket. This bubble-bed becomes clearly thinner, when going toward the end of the tank. There are also round DAF tanks which are based on the same hydraulic principles as the rectangular ones presented above. A special application of DAF called the flotation filter was invented at the very end of the 1960s. It is a combination of flotation and rapid sand filtration, both of those being placed in the same tank. Flotation takes place in the upper part of the tank and the filter has been placed in the lower part of it. The direction of water flow is now vertically down from the free surface of water in the tank toward the deep-bed filter. This controls the direction of flow in the flotation space of the tank above the filter bed. The flow rate of water in flotation filters may be 10-15 m/h, but the flow conditions are still laminar. It is the threat that the head-loss of filters would grow too rapidly which in practice is limiting the hydraulic flow rate of flotation filters in this area. The third generation of DAF has been developed at the end of the 1990s. The operational idea is based on that of the flotation filter. The filter bed on the bottom of the tank has been replaced by a thin stiff plate with plenty of round orifices throughout the plate. This plate, having a very much lower flowing resistance than a sand filter can have, controls the vertical flow of water in the flotation space above the plate and distributes it evenly throughout the horizontal cross-section of the tank. The flotation tank is almost square seen from above and its depth is clearly more than the length and breadth of it. This kind of flotation unit can be operated with flow rates of water in the range 25-40 m/l. Even a flow rate of more than 60 m/h has been reported from this kind of DAF-units. There is no risk of clogging of the plate by suspended solids which could limit the flow rate. This is to say that it is possible to operate DAF also in turbulent flow conditions. The depth of the micro-bubble bed below the surface of water can be 1.5-2.5 m. There actually is a continuously regenerated micro-bubble bed in the tank filtering water which is going through this bed. The lower surface of the micro-bubble bed is really a horizontal one a little bit above the plate controlling the flow in the flotation space. The clarified water below the micro-bubble bed is totally clear. It can be said that in this case the removal of suspended solids takes place much more by filtering water by a deep-bed micro-bubble filter than by attaching micro-bubbles onto solids, when both of these are mixed with each other in the inlet shaft of the flotation unit, because the retention time of water in the inlet shaft is very short indeed.
Design and simulation of flight control system for man-portable micro reconnaissance quadcopter
NASA Astrophysics Data System (ADS)
Yin, Xinfan; Zhang, Daibing; Fang, Qiang; Shen, Lincheng
2017-10-01
The quadcopter has been widely used in the field of aerial photography and environmental detection, because of its advantages of VTOL, simple structure, and easy-control. In the field of urban anti-terrorism or special operations, micro reconnaissance quadcpter has its unique advantages such as all-weather taking off and landing, small noise and so on, and it is very popular with special forces and riot police. This paper aims at the flight control problem of the micro quadcopter, for the purposes of attitude stabilization control and trajectory tracking control of the micro quadcopter, first, the modeling of the micro quadcopter is presented. And using the MATLAB/SIMULINK toolbox to build the flight controller of the micro quadcopter, and then simulation analysis and real flight test are given. The results of the experiment show that the designed PID controller can correct the flight attitude shift effectively and track the planned tracks well, and can achieve the goal of stable and reliable flight of the quadcopter. It can be a useful reference for the flight control system design of future special operations micro UAV.
Active Fail-Safe Micro-Array Flow Control for Advanced Embedded Propulsion Systems
NASA Technical Reports Server (NTRS)
Anderson, Bernhard H.; Mace, James L.; Mani, Mori
2009-01-01
The primary objective of this research effort was to develop and analytically demonstrate enhanced first generation active "fail-safe" hybrid flow-control techniques to simultaneously manage the boundary layer on the vehicle fore-body and to control the secondary flow generated within modern serpentine or embedded inlet S-duct configurations. The enhanced first-generation technique focused on both micro-vanes and micro-ramps highly-integrated with micro -jets to provide nonlinear augmentation for the "strength' or effectiveness of highly-integrated flow control systems. The study focused on the micro -jet mass flow ratio (Wjet/Waip) range from 0.10 to 0.30 percent and jet total pressure ratios (Pjet/Po) from 1.0 to 3.0. The engine bleed airflow range under study represents about a 10 fold decrease in micro -jet airflow than previously required. Therefore, by pre-conditioning, or injecting a very small amount of high-pressure jet flow into the vortex generated by the micro-vane and/or micro-ramp, active flow control is achieved and substantial augmentation of the controlling flow is realized.
SLUDGE BATCH 6/TANK 40 SIMULANT CHEMICAL PROCESS CELL SIMULATIONS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Koopman, David
2010-04-28
Phase III simulant flowsheet testing was completed using the latest composition estimates for SB6/Tank 40 feed to DWPF. The goals of the testing were to determine reasonable operating conditions and assumptions for the startup of SB6 processing in the DWPF. Testing covered the region from 102-159% of the current DWPF stoichiometric acid equation. Nitrite ion concentration was reduced to 90 mg/kg in the SRAT product of the lowest acid run. The 159% acid run reached 60% of the DWPF Sludge Receipt and Adjustment Tank (SRAT) limit of 0.65 lb H2/hr, and then sporadically exceeded the DWPF Slurry Mix Evaporator (SME)more » limit of 0.223 lb H2/hr. Hydrogen generation rates peaked at 112% of the SME limit, but higher than targeted wt% total solids levels may have been partially responsible for rates seen. A stoichiometric factor of 120% met both objectives. A processing window for SB6 exists from 102% to something close to 159% based on the simulant results. An initial recommendation for SB6 processing is at 115-120% of the current DWPF stoichiometric acid equation. The addition of simulated Actinide Removal Process (ARP) and Modular Caustic Side Solvent Extraction Unit (MCU) streams to the SRAT cycle had no apparent impact on the preferred stoichiometric factor. Hydrogen generation occurred continuously after acid addition in three of the four tests. The three runs at 120%, 118.4% with ARP/MCU, and 159% stoichiometry were all still producing around 0.1 lb hydrogen/hr at DWPF scale after 36 hours of boiling in the SRAT. The 120% acid run reached 23% of the SRAT limit and 37% of the SME limit. Conversely, nitrous oxide generation was subdued compared to previous sludge batches, staying below 29 lb/hr in all four tests or about a fourth as much as in comparable SB4 testing. Two processing issues, identified during SB6 Phase II flowsheet testing and qualification simulant testing, were monitored during Phase III. Mercury material balance closure was impacted by acid stoichiometry, and significant mercury was not accounted for in the highest acid run. Coalescence of elemental mercury droplets in the mercury water wash tank (MWWT) appeared to degrade with increasing stoichiometry. Observations were made of mercury scale formation in the SRAT condenser and MWWT. A tacky mercury amalgam with Rh, Pd, and Cu, plus some Ru and Ca formed on the impeller at 159% acid. It contained a significant fraction of the available Pd, Cu, and Rh as well as about 25% of the total mercury charged. Free (elemental) mercury was found in all of the SME products. Ammonia scrubbers were used during the tests to capture off-gas ammonia for material balance purposes. Significant ammonium ion formation was again observed during the SRAT cycle, and ammonia gas entered the off-gas as the pH rose during boiling. Ammonium ion production was lower than in the SB6 Phase II and the qualification simulant testing. Similar ammonium ion formation was seen in the ARP/MCU simulation as in the 120% flowsheet run. A slightly higher pH caused most of the ammonium to vaporize and collect in the ammonia scrubber reflux solution. Two periods of foaminess were noted. Neither required additional antifoam to control the foam growth. A steady foam layer formed during reflux in the 120% acid run. It was about an inch thick, but was 2-3 times more volume of bubbles than is typically seen during reflux. A similar foam layer also was seen during caustic boiling of the simulant during the ARP addition. While frequently seen with the radioactive sludge, foaminess during caustic boiling with simulants has been relatively rare. Two further flowsheet tests were performed and will be documented separately. One test was to evaluate the impact of process conditions that match current DWPF operation (lower rates). The second test was to evaluate the impact of SRAT/SME processing on the rheology of a modified Phase III simulant that had been made five times more viscous using ultrasonication.« less
Kim, Yong Tae; Lee, Dohwan; Heo, Hyun Young; Sim, Jeong Eun; Woo, Kwang Man; Kim, Do Hyun; Im, Sung Gap; Seo, Tae Seok
2016-04-15
A fully integrated slidable and valveless microsystem, which performs solid phase DNA extraction (SPE), micro-polymerase chain reaction (μPCR) and micro-capillary electrophoresis (μCE) coupled with a portable genetic analyser, has been developed for forensic genotyping. The use of a slidable chip, in which a 1 μL-volume of the PCR chamber was patterned at the center, does not necessitate any microvalves and tubing systems for fluidic control. The functional micro-units of SPE, μPCR, and μCE were fabricated on a single glass wafer by conventional photolithography, and the integrated microdevice consists of three layers: from top to bottom, a slidable chip, a channel wafer in which a SPE chamber, a mixing microchannel, and a CE microchannel were fabricated, and a Ti/Pt resistance temperature detector (RTD) wafer. The channel glass wafer and the RTD glass wafer were thermally bonded, and the slidable chip was placed on the designated functional unit. The entire process from the DNA extraction using whole human blood sample to identification of target Y chromosomal short tandem repeat (STR) loci was serially carried out with simply sliding the slidable chamber from one to another functional unit. Monoplex and multiplex detection of amelogenin and mini Y STR loci were successfully analysed on the integrated slidable SPE-μPCR-μCE microdevice by using 1 μL whole human blood within 60 min. The proposed advanced genetic analysis microsystem is capable of point-of-care DNA testing with sample-in-answer-out capability, more importantly, without use of complicated microvalves and microtubing systems for liquid transfer. Copyright © 2015 Elsevier B.V. All rights reserved.
Chemical Oxygen Demand abatement in sewage using Micro-Aeration Enhanced Ecological Floating Bed
NASA Astrophysics Data System (ADS)
Shi, Hongle; Zhou, Gaofeng; Liu, Yiqing; Tan, Jiancong; Fu, Yongsheng
2018-02-01
The traditional ecological floating bed combined with micro-aeration system and artificial medium was developed for the removal of contaminants and remediation of surface water. This micro-aeration enhanced ecological floating bed (MAEEFB) consisted of aeration unit, microbial processing unit and aquatic plant unit. Batch experiments were conducted in different operating conditions on the removal of chemical oxygen demand (COD) in the sewage using MAEEFB. The removal rate of COD by MAEEFB, enhanced ecological floating bed (EEFB) and traditional ecological floating bed (TEFB) in the same reaction conditions was 59.2%, 56.9% and 30.6%, respectively, indicating that the combination of micro-aeration system and artificial medium could enhance the removal efficiency of COD in TEFB. In MAEEFB, the aeration intensity should be designed reasonablely considering both treatment efficiency and operation cost. Only increasing the specific surface area of the packing cannot effectively improve the purification efficiency of water. Factors like packing material, ability of intercepting organics and complicated extent of microorganisms attaching on the packing should also be considered.
Use of New Industrial Coatings for the U.S. Navy Waterfront Structures
2008-12-01
utilized as a coating for the interior and exterior of piping systems, which either are located in harsh environments or are transporting substances with...typical application process, a separate set of test Table 7. MCU Coating Systems (SSPC SP 10 Surfaces) (5). SystelD CoatiIli System A Zinc -rich urethane...urethane/MID & AI-filled Urethane/MIO-filled urethane 315/315/314 336/336/336 340/340/336 ~ Micaceous iron oxide. \\) Aluminum. C Zinc . 12 as well as an
[A Smart Low-Power-Consumption ECG Monitor Based on MSP430F5529 and CC2540].
Gong, Yuan; Cao, Jin; Luo, Zehui; Zhou, Guohui
2015-07-01
A design of ECG monitor was presented in this paper. It is based on the latest MCU and BLE4.0 technologies and can interact with multi-platform smart devices with extra low power consumption. Besides, a clinical expansion part can realize functions including displaying the real-time ECG and heart rate curve, reading abnormal ECG signals stored in the monitor, and setting alarm threshold. These functions are suitable for follow-up use.
NASA Astrophysics Data System (ADS)
Zhang, Shubin; Zhang, Yufeng; Chen, Junyu; Yin, Congwen; Liu, Xiaowei
2018-06-01
In this paper, an integrated reformed methanol fuel cell (RMFC) as a portable power source is designed, fabricated and tested. The RMFC consists of a methanol steam reformer (MSR), a high temperature proton exchange membrane fuel cell (HT-PEMFC) stack, a microcontroller unit (MCU) and other auxiliaries. First, a system model based on Matlab/Simulink is established to investigate the mass and energy transport characteristics within the whole system. The simulation results suggest a hydrogen flow rate of at least 670 sccm is needed for the system to output 30 W and simultaneously maintain thermal equilibrium. Second, a metallic MSR and an HT-PEMFC stack with 12 cells are fabricated and tested. The tests show that the RMFC system is able to function normally when the performances of all the components meet the minimum requirements. At last, in the experiment of successfully powering a laptop, the RMFC system exhibits a stable performance during the complete work flow of all the phases, namely start-up, output and shutdown. Moreover, with a conservative design of 20 W power rating, maximum energy conversion efficiency of the RMFC system can be achieved (36%), and good stability in long-term operation is shown.
Analytical Results from Routine DSSHT and SEHT Monthly Samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, T. B.
2016-08-17
Strip Effluent Hold Tank (SEHT) and Decontaminated Salt Solution Hold Tank (DSSHT) samples from several of the “microbatches” of Integrated Salt Disposition Project (ISDP) Salt Batch (“Macrobatch”) 8B have been analyzed for 238Pu, 90Sr, 137Cs, cations (Inductively Coupled Plasma Emission Spectroscopy - ICPES), and anions (Ion Chromatography Anions - IC-A). The analytical results from the current microbatch samples are similar to those from previous macrobatch samples. The Actinide Removal Process (ARP) and the Modular Caustic-Side Solvent Extraction Unit (MCU) continue to show more than adequate Pu and Sr removal for times when monosodium titanate (MST) is used. Even with nomore » MST strike being performed there exists some small Pu and Sr removal, likely from filtration of fines containing these elements. The Cs removal continues to be excellent, with decontamination factors (DF) averaging 16,400. The bulk chemistry of the DSSHT and SEHT samples do not show any signs of unusual behavior. SRNL recommends that a sample of the strip feed be analyzed for cation and anion content if a further decline in boron concentration is noted in future SEHT samples.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, T. B.; Fink, S. D.
Strip Effluent Hold Tank (SEHT), Decontaminated Salt Solution Hold Tank (DSSHT), and Caustic Wash Tank (CWT) samples from several of the ?microbatches? of Integrated Salt Disposition Project (ISDP) Salt Batch (?Macrobatch?) 4 have been analyzed for {sup 238}Pu, {sup 90}Sr, {sup 137}Cs, and by inductively-coupled plasma emission spectroscopy (ICPES). Furthermore, samples from the CWT have been analyzed by a variety of methods to investigate a decline in the decontamination factor (DF) of the cesium observed at MCU. The results indicate good decontamination performance within process design expectations. While the data set is sparse, the results of this set and themore » previous set of results for Macrobatch 3 samples indicate generally consistent operations. There is no indication of a disruption in plutonium and strontium removal. The average cesium DF and concentration factor (CF) for samples obtained from Macrobatch 4 are slightly lower than for Macrobatch 3, but still well within operating parameters. The DSSHT samples show continued presence of titanium, likely from leaching of the monosodium titanate in Actinide Removal Process (ARP).« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roach, Benjamin D.; Williams, Neil J.; Moyer, Bruce A.
As part of the ongoing development of the Next-Generation Caustic-Side Solvent Extraction (NGS) process, the thermal stability of the process solvent was investigated and shown to be adequate for industrial application. The solvent was thermally treated at 35 C over a period of 13 months whilst in dynamic contact with each of the aqueous phases of the current NGS process, namely SRS 15 (a highly caustic waste simulant), sodium hydroxide scrub solution (0.025 M), and boric acid strip solution (0.01 M). The effect of thermal treatment was evaluated by assessing batch extract/scrub/strip performance as a function of time, by monitoringmore » the sodium extraction capacity of the solvent, and by analysis of the solvent using electrospray mass spectrometry. Current studies indicate that the NGS solvent should be thermally robust for a period of XXX months at the Modular Caustic-Side Solvent Extraction Unit (MCU) pilot plant located at Savannah River Site. Furthermore, the guanidine suppressor appears to be the solvent component most significantly impacted by thermal treatment of the solvent, showing significant degradation over time.« less
Roach, Benjamin D.; Williams, Neil J.; Moyer, Bruce A.
2015-09-02
As part of the ongoing development of the Next-Generation Caustic-Side Solvent Extraction (NGS) process, the thermal stability of the process solvent was investigated and shown to be adequate for industrial application. The solvent was thermally treated at 35 C over a period of 13 months whilst in dynamic contact with each of the aqueous phases of the current NGS process, namely SRS 15 (a highly caustic waste simulant), sodium hydroxide scrub solution (0.025 M), and boric acid strip solution (0.01 M). The effect of thermal treatment was evaluated by assessing batch extract/scrub/strip performance as a function of time, by monitoringmore » the sodium extraction capacity of the solvent, and by analysis of the solvent using electrospray mass spectrometry. Current studies indicate that the NGS solvent should be thermally robust for a period of XXX months at the Modular Caustic-Side Solvent Extraction Unit (MCU) pilot plant located at Savannah River Site. Furthermore, the guanidine suppressor appears to be the solvent component most significantly impacted by thermal treatment of the solvent, showing significant degradation over time.« less
Experimental Methods to Characterize Nonlinear Vibration of Flapping Wing Micro Air Vehicles
2007-03-01
EXPERIMENTAL METHODS TO CHARACTERIZE NONLINEAR VIBRATION OF FLAPPING WING MICRO AIR VEHICLES THESIS Adam P. Tobias, Captain, USAF...AFIT/GAE/ENY/07-M23 DEPARTMENT OF THE AIR FORCE AIR UNIVERSITY AIR FORCE INSTITUTE OF TECHNOLOGY Wright-Patterson Air Force Base, Ohio...author and do not reflect the official policy or position of the United States Air Force, Department of Defense, or the United States Government
ERIC Educational Resources Information Center
Kahle, Jane Butler
Four audio-tutorial units were developed as part of this study to determine the effectiveness of the use of advanced organizers, based on Ausubel's theories, for meaningful learning experiences. In this study an advanced organizer was developed and given to half of the subjects prior to the instructional sequence. A series of micro-learning tasks,…
A novel piezoelectric quartz micro-array immunosensor for detection of immunoglobulinE.
Yao, Chunyan; Chen, Qinghai; Chen, Ming; Zhang, Bo; Luo, Yang; Huang, Qing; Huang, Junfu; Fu, Weiling
2006-12-01
A novel multi-channel 2 x 5 model of piezoelectric (PZ) micro-array immunosensor has been developed for quantitative detection of human immunoglobulinE (IgE) in serum. Every crystal unit of the fabricated piezoelectric IgE micro-array immunosensor can oscillate without interfering each other. A multi-channel 2 x 5 model micro-array immunosensor as compared with the traditional one-channel immunosensor can provide eight times higher detection speeds for IgE assay. The anti-IgE antibody is deposited on the gold electrode's surface of 10 MHz AT-cut quartz crystals by SPA (staphylococcal protein A), and serves as an antibody recognizing layer. The highly ordered antibody monolayers ensure well-controlled surface structure and offer many advantages to the performance of the sensor. The uniform amount of antibody monolayer coated by the SPA is good, and non-specific reaction caused by other immunoglobulin in sample is found. The fabricated PZ immunosensor can be used for human IgE determination in the range of 5-300 IU/ml with high precision (CV is 4%). 50 human serum samples were detected by the micro-array immunosensor, and the results agreed well with those given by the commercially ELISA test kits. The correlation coefficient is 0.94 between ELISA and PZ immunosensor. After regeneration with NaOH the coated immunosensor can be reused 6 times without appreciable loss of activity.
Structure determination of {alpha}-La{sub 6}W{sub 2}O{sub 15}
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chambrier, M-H., E-mail: marie-helene.chambier.etu@univ-lemans.f; Ibberson, R.M.; Goutenoire, F., E-mail: francois.goutenoire@univ-lemans.f
2010-06-15
The structure of the high temperature alpha form of La{sub 6}W{sub 2}O{sub 15} has been determined ab-initio from high temperature laboratory X-ray and neutron time-of-flight data. This tungstate crystallizes in the non-centrosymmetric orthorhombic space group (No. 20) C222{sub 1}, with Z=2, a=12.6250(2) A, b=9.1875(1) A, c=5.9688(1) A. The structure comprises [O{sub 2}La{sub 3}] infinite ribbons and is better described by the structural formula [O{sub 2}La{sub 3}]{sub 2}[WO{sub 5.5}]{sub 2}. Using this description we can understand the strong structural similarity of the present compound with compounds of the general composition BiM{sub 2}AO{sub 6} (M=Cu, Mg, Zn, Mn, Cd, Ca, Pb; A=P,more » As, V) described as [O{sub 2}M{sub 2}Bi][AO{sub 4}]. The [WO{sub 5.5}] entity implies oxygen disorder in the material. - Graphical abstract: Projection of the polyhedra around the tungsten atom. Atoms labelled in grey are occupied at 50%. Short oxygen-oxygen distances are marked. The polyhedra represents WO{sub 5.5} that is related to the structural unit W{sub 2}O{sub 11} unit. Alpha-La{sub 6}W{sub 2}O{sub 15} could be described as [O{sub 2}La{sub 3}]{sub 2}[WO{sub 5.5}]{sub 2}.« less
Development of portable health monitoring system for automatic self-blood glucose measurement
NASA Astrophysics Data System (ADS)
Kim, Huijun; Mizuno, Yoshihumi; Nakamachi, Eiji; Morita, Yusuke
2010-02-01
In this study, a new HMS (Health Monitoring System) device is developed for diabetic patient. This device mainly consists of I) 3D blood vessel searching unit and II) automatic blood glucose measurement (ABGM) unit. This device has features such as 1)3D blood vessel location search 2) laptop type, 3) puncturing a blood vessel by using a minimally invasive micro-needle, 4) very little blood sampling (10μl), and 5) automatic blood extraction and blood glucose measurement. In this study, ABGM unit is described in detail. It employs a syringe type's blood extraction mechanism because of its high accuracy. And it consists of the syringe component and the driving component. The syringe component consists of a syringe itself, a piston, a magnet, a ratchet and a micro-needle whose inner diameter is about 80μm. And the syringe component is disposable. The driving component consists of body parts, a linear stepping motor, a glucose enzyme sensor and a slider for accurate positioning control. The driving component has the all-in-one mechanism with a glucose enzyme sensor for compact size and stable blood transfer. On designing, required thrust force to drive the slider is designed to be greater than the value of the blood extraction force. Further, only one linear stepping motor is employed for blood extraction and transportation processes. The experimental result showed more than 80% of volume ratio under the piston speed 2.4mm/s. Further, the blood glucose was measured successfully by using the prototype unit. Finally, the availability of our ABGM unit was confirmed.
Automatic-Control System for Safer Brazing
NASA Technical Reports Server (NTRS)
Stein, J. A.; Vanasse, M. A.
1986-01-01
Automatic-control system for radio-frequency (RF) induction brazing of metal tubing reduces probability of operator errors, increases safety, and ensures high-quality brazed joints. Unit combines functions of gas control and electric-power control. Minimizes unnecessary flow of argon gas into work area and prevents electrical shocks from RF terminals. Controller will not allow power to flow from RF generator to brazing head unless work has been firmly attached to head and has actuated micro-switch. Potential shock hazard eliminated. Flow of argon for purging and cooling must be turned on and adjusted before brazing power applied. Provision ensures power not applied prematurely, causing damaged work or poor-quality joints. Controller automatically turns off argon flow at conclusion of brazing so potentially suffocating gas does not accumulate in confined areas.
Airfoil-shaped micro-mixers for reducing fouling on membrane surfaces
Ho, Clifford K; Altman, Susan J; Clem, Paul G; Hibbs, Michael; Cook, Adam W
2012-10-23
An array of airfoil-shaped micro-mixers that enhances fluid mixing within permeable membrane channels, such as used in reverse-osmosis filtration units, while minimizing additional pressure drop. The enhanced mixing reduces fouling of the membrane surfaces. The airfoil-shaped micro-mixer can also be coated with or comprised of biofouling-resistant (biocidal/germicidal) ingredients.
Vasan, S N Swetadri; Ionita, Ciprian N; Titus, A H; Cartwright, A N; Bednarek, D R; Rudin, S
2012-02-23
We present the image processing upgrades implemented on a Graphics Processing Unit (GPU) in the Control, Acquisition, Processing, and Image Display System (CAPIDS) for the custom Micro-Angiographic Fluoroscope (MAF) detector. Most of the image processing currently implemented in the CAPIDS system is pixel independent; that is, the operation on each pixel is the same and the operation on one does not depend upon the result from the operation on the other, allowing the entire image to be processed in parallel. GPU hardware was developed for this kind of massive parallel processing implementation. Thus for an algorithm which has a high amount of parallelism, a GPU implementation is much faster than a CPU implementation. The image processing algorithm upgrades implemented on the CAPIDS system include flat field correction, temporal filtering, image subtraction, roadmap mask generation and display window and leveling. A comparison between the previous and the upgraded version of CAPIDS has been presented, to demonstrate how the improvement is achieved. By performing the image processing on a GPU, significant improvements (with respect to timing or frame rate) have been achieved, including stable operation of the system at 30 fps during a fluoroscopy run, a DSA run, a roadmap procedure and automatic image windowing and leveling during each frame.
Optimal Control of Shock Wave Turbulent Boundary Layer Interactions Using Micro-Array Actuation
NASA Technical Reports Server (NTRS)
Anderson, Bernhard H.; Tinapple, Jon; Surber, Lewis
2006-01-01
The intent of this study on micro-array flow control is to demonstrate the viability and economy of Response Surface Methodology (RSM) to determine optimal designs of micro-array actuation for controlling the shock wave turbulent boundary layer interactions within supersonic inlets and compare these concepts to conventional bleed performance. The term micro-array refers to micro-actuator arrays which have heights of 25 to 40 percent of the undisturbed supersonic boundary layer thickness. This study covers optimal control of shock wave turbulent boundary layer interactions using standard micro-vane, tapered micro-vane, and standard micro-ramp arrays at a free stream Mach number of 2.0. The effectiveness of the three micro-array devices was tested using a shock pressure rise induced by the 10 shock generator, which was sufficiently strong as to separate the turbulent supersonic boundary layer. The overall design purpose of the micro-arrays was to alter the properties of the supersonic boundary layer by introducing a cascade of counter-rotating micro-vortices in the near wall region. In this manner, the impact of the shock wave boundary layer (SWBL) interaction on the main flow field was minimized without boundary bleed.
A portable hardware-in-the-loop (HIL) device for automotive diagnostic control systems.
Palladino, A; Fiengo, G; Lanzo, D
2012-01-01
In-vehicle driving tests for evaluating the performance and diagnostic functionalities of engine control systems are often time consuming, expensive, and not reproducible. Using a hardware-in-the-loop (HIL) simulation approach, new control strategies and diagnostic functions on a controller area network (CAN) line can be easily tested in real time, in order to reduce the effort and the cost of the testing phase. Nowadays, spark ignition engines are controlled by an electronic control unit (ECU) with a large number of embedded sensors and actuators. In order to meet the rising demand of lower emissions and fuel consumption, an increasing number of control functions are added into such a unit. This work aims at presenting a portable electronic environment system, suited for HIL simulations, in order to test the engine control software and the diagnostic functionality on a CAN line, respectively, through non-regression and diagnostic tests. The performances of the proposed electronic device, called a micro hardware-in-the-loop system, are presented through the testing of the engine management system software of a 1.6 l Fiat gasoline engine with variable valve actuation for the ECU development version. Copyright © 2011 ISA. Published by Elsevier Ltd. All rights reserved.
Molecules Designed to Contain Two Weakly Coupled Spins with a Photoswitchable Spacer.
Uber, Jorge Salinas; Estrader, Marta; Garcia, Jordi; Lloyd-Williams, Paul; Sadurní, Anna; Dengler, Dominik; van Slageren, Joris; Chilton, Nicholas F; Roubeau, Olivier; Teat, Simon J; Ribas-Ariño, Jordi; Aromí, Guillem
2017-10-04
Controlling the charges and spins of molecules lies at the heart of spintronics. A photoswitchable molecule consisting of two independent spins separated by a photoswitchable moiety was designed in the form of new ligand H 4 L, which features a dithienylethene photochromic unit and two lateral coordinating moieties, and yields molecules with [MM⋅⋅⋅MM] topology. Compounds [M 4 L 2 (py) 6 ] (M=Cu, 1; Co, 2; Ni, 3; Zn, 4) were prepared and studied by single-crystal X-ray diffraction (SCXRD). Different metal centers can be selectively distributed among the two chemically distinct sites of the ligand, and this enables the preparation of many double-spin systems. Heterometallic [MM'⋅⋅⋅M'M] analogues with formulas [Cu 2 Ni 2 L 2 (py) 6 ] (5), [Co 2 Ni 2 L 2 (py) 6 ] (6), [Co 2 Cu 2 L 2 (py) 6 ] (7), [Cu 2 Zn 2 L 2 (py) 6 ] (8), and [Ni 2 Zn 2 L 2 (py) 6 ] (9) were prepared and analyzed by SCXRD. Their composition was established unambiguously. All complexes exhibit two weakly interacting [MM'] moieties, some of which embody two-level quantum systems. Compounds 5 and 8 each exhibit a pair of weakly coupled S=1/2 spins that show quantum coherence in pulsed Q-band EPR spectroscopy, as required for quantum computing, with good phase memory times (T M =3.59 and 6.03 μs at 7 K). Reversible photoswitching of all the molecules was confirmed in solution. DFT calculations on 5 indicate that the interaction between the two spins of the molecule can be switched on and off on photocyclization. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Iyer, Abishek K.; Rudyk, Brent W.; Lin, Xinsong; Singh, Harpreet; Sharma, Arzoo Z.; Wiebe, Christopher R.; Mar, Arthur
2015-09-01
The quaternary rare-earth chalcogenides RE3CuGaS7 and RE3CuGaSe7 (RE=La-Nd) have been prepared by reactions of the elements at 1050 °C and 900 °C, respectively. They crystallize in the noncentrosymmetric La3CuSiS7-type structure (hexagonal, space group P63, Z=2) in which the a-parameter is largely controlled by the RE component (a=10.0-10.3 Å for the sulfides and 10.3-10.6 Å for the selenides) whereas the c-parameter is essentially fixed by the choice of Ga and chalcogen atoms within tetrahedral units (c=6.1 Å for the sulfides and 6.4 Å for the selenides). They extend the series RE3MGaCh7, previously known for divalent metal atoms (M=Mn-Ni), differing in that the Cu atoms in RE3CuGaCh7 occupy trigonal planar sites instead of octahedral sites. Among quaternary chalcogenides RE3MM‧Ch7, the combination of monovalent (M=Cu) and trivalent (M‧=Ga) metals is unusual because it appears to violate the condition of charge balance satisfied by most La3CuSiS7-type compounds. The possibility of divalent Cu atoms was ruled out by bond valence sum analysis, magnetic measurements, and X-ray photoelectron spectroscopy. The electron deficiency in RE3CuGaCh7 is accommodated through S-based holes at the top of the valence band, as shown by band structure calculations on La3CuGaS7. An optical band gap of about 2.0 eV was found for La3CuGaSe7.
Design of self-contained sensor for monitoring of deep-sea offshore platform
NASA Astrophysics Data System (ADS)
Song, Yang; Yu, Yan; Zhang, Chunwei; Dong, Weijie; Ou, Jinping
2013-04-01
Offshore platform, which is the base of the production and living in the sea, is the most important infrastructure for developing oil and gas resources. At present, there are almost 6500 offshore platforms servicing in the 53 countries' sea areas around the world, creating great wealth for the world. In general, offshore platforms may work for 20 years, however, offshore platforms are expensive, complex, bulky, and so many of them are on extended active duty. Because of offshore platforms servicing in the harsh marine environment for a long time, the marine environment have a great impact on the offshore platforms. Besides, with the impact and erosion of seawater, and material aging, the offshore platform is possible to be in unexpected situations when a badly sudden situation happens. Therefore, it is of great significance to monitor the marine environment and offshore platforms. The self-contained sensor for deep-sea offshore platform with its unique design, can not only effectively extend the working time of the sensor with the capability of converting vibration energy to electrical energy, but also simultaneously collect the data of acceleration, inclination, temperature and humidity of the deep sea, so that we can achieve the purpose of monitoring offshore platforms through analyzing the collected data. The self-contained sensor for monitoring of deep-sea offshore platform includes sensing unit, data collecting and storage unit, the energy supply unit. The sensing unit with multi-variables, consists of an accelerometer LIS344ALH, an inclinometer SCA103T and a temperature and humidity sensor SHT11; the data collecting and storage unit includes the MSP430 low-power MCU, large capacity memory, clock circuit and the communication interface, the communication interface includes USB interface, serial ports and wireless interface; in addition, the energy supply unit, converting vibration to electrical energy to power the overall system, includes the electromagnetic generator, voltage multiplier circuit and a super capacitor which can withstand virtually unlimited number of charge-discharge cycles. When the seawater impacts on offshore platforms to produce vibration, electromagnetic generator converts vibration to electrical energy, its output(~ 1 V 50 Hz AC) is stepped up and rectified by a voltage multiplier circuit, and the energy is stored in a super capacitor. It is controlled by the MSP430 that monitors the voltage level on the super capacitor. The super capacitor charges the Li-ion battery when the voltage on the super capacitor reaches a threshold, then the whole process of energy supply is completed. The self-contained sensor for deep-sea offshore platform has good application prospects and practical value with small size, low power, being easy to install, converting vibration energy to supply power and high detection accuracy.
Micro grid control strategy of DFIG unit based on improved DC grid connected topology
NASA Astrophysics Data System (ADS)
Zongze, Xia; Fei, Xia; Zhixiong, Yang
2017-05-01
Aiming to the application of the DFIG connected to DC-Microgrids, an improved topology for the DFIG connected to DC-Microgrids is taken into account in this thesis. The stator side loses the support of voltage and frequency of AC point of common coupling bus. A novel control method suitable to the stator side converter (SSC) and the rotor side converter (RSC) of the topology is proposed. The independent control of stator voltage and frequency, the decoupled control of power and variable speed constant frequency of DFIG are achieved in the doubly-fed induction generator connected to DC-Microgrids. which can enhance the capacity of active power transmission of DFIG during the voltage variation.
MicroRNA expression in benign breast tissue and risk of subsequent invasive breast cancer.
Rohan, Thomas; Ye, Kenny; Wang, Yihong; Glass, Andrew G; Ginsberg, Mindy; Loudig, Olivier
2018-01-01
MicroRNAs are endogenous, small non-coding RNAs that control gene expression by directing their target mRNAs for degradation and/or posttranscriptional repression. Abnormal expression of microRNAs is thought to contribute to the development and progression of cancer. A history of benign breast disease (BBD) is associated with increased risk of subsequent breast cancer. However, no large-scale study has examined the association between microRNA expression in BBD tissue and risk of subsequent invasive breast cancer (IBC). We conducted discovery and validation case-control studies nested in a cohort of 15,395 women diagnosed with BBD in a large health plan between 1971 and 2006 and followed to mid-2015. Cases were women with BBD who developed subsequent IBC; controls were matched 1:1 to cases on age, age at diagnosis of BBD, and duration of plan membership. The discovery stage (316 case-control pairs) entailed use of the Illumina MicroRNA Expression Profiling Assay (in duplicate) to identify breast cancer-associated microRNAs. MicroRNAs identified at this stage were ranked by the strength of the correlation between Illumina array and quantitative PCR results for 15 case-control pairs. The top ranked 14 microRNAs entered the validation stage (165 case-control pairs) which was conducted using quantitative PCR (in triplicate). In both stages, linear regression was used to evaluate the association between the mean expression level of each microRNA (response variable) and case-control status (independent variable); paired t-tests were also used in the validation stage. None of the 14 validation stage microRNAs was associated with breast cancer risk. The results of this study suggest that microRNA expression in benign breast tissue does not influence the risk of subsequent IBC.
MicroRNA expression in benign breast tissue and risk of subsequent invasive breast cancer
Ye, Kenny; Wang, Yihong; Ginsberg, Mindy; Loudig, Olivier
2018-01-01
MicroRNAs are endogenous, small non-coding RNAs that control gene expression by directing their target mRNAs for degradation and/or posttranscriptional repression. Abnormal expression of microRNAs is thought to contribute to the development and progression of cancer. A history of benign breast disease (BBD) is associated with increased risk of subsequent breast cancer. However, no large-scale study has examined the association between microRNA expression in BBD tissue and risk of subsequent invasive breast cancer (IBC). We conducted discovery and validation case-control studies nested in a cohort of 15,395 women diagnosed with BBD in a large health plan between 1971 and 2006 and followed to mid-2015. Cases were women with BBD who developed subsequent IBC; controls were matched 1:1 to cases on age, age at diagnosis of BBD, and duration of plan membership. The discovery stage (316 case-control pairs) entailed use of the Illumina MicroRNA Expression Profiling Assay (in duplicate) to identify breast cancer-associated microRNAs. MicroRNAs identified at this stage were ranked by the strength of the correlation between Illumina array and quantitative PCR results for 15 case-control pairs. The top ranked 14 microRNAs entered the validation stage (165 case-control pairs) which was conducted using quantitative PCR (in triplicate). In both stages, linear regression was used to evaluate the association between the mean expression level of each microRNA (response variable) and case-control status (independent variable); paired t-tests were also used in the validation stage. None of the 14 validation stage microRNAs was associated with breast cancer risk. The results of this study suggest that microRNA expression in benign breast tissue does not influence the risk of subsequent IBC. PMID:29432432
Online Optimization Method for Operation of Generators in a Micro Grid
NASA Astrophysics Data System (ADS)
Hayashi, Yasuhiro; Miyamoto, Hideki; Matsuki, Junya; Iizuka, Toshio; Azuma, Hitoshi
Recently a lot of studies and developments about distributed generator such as photovoltaic generation system, wind turbine generation system and fuel cell have been performed under the background of the global environment issues and deregulation of the electricity market, and the technique of these distributed generators have progressed. Especially, micro grid which consists of several distributed generators, loads and storage battery is expected as one of the new operation system of distributed generator. However, since precipitous load fluctuation occurs in micro grid for the reason of its smaller capacity compared with conventional power system, high-accuracy load forecasting and control scheme to balance of supply and demand are needed. Namely, it is necessary to improve the precision of operation in micro grid by observing load fluctuation and correcting start-stop schedule and output of generators online. But it is not easy to determine the operation schedule of each generator in short time, because the problem to determine start-up, shut-down and output of each generator in micro grid is a mixed integer programming problem. In this paper, the authors propose an online optimization method for the optimal operation schedule of generators in micro grid. The proposed method is based on enumeration method and particle swarm optimization (PSO). In the proposed method, after picking up all unit commitment patterns of each generators satisfied with minimum up time and minimum down time constraint by using enumeration method, optimal schedule and output of generators are determined under the other operational constraints by using PSO. Numerical simulation is carried out for a micro grid model with five generators and photovoltaic generation system in order to examine the validity of the proposed method.
Liu, Xiaoling; Zhang, Ke; Fan, Liangqian; Luo, Hongbing; Jiang, Mingshu; Anderson, Bruce C; Li, Mei; Huang, Bo; Yu, Lijuan; He, Guozhu; Wang, Jingting; Pu, Aiping
2018-06-16
It is very important to control methane emissions to mitigate global warming. An intermittent micro-aeration control system was used to control methane emissions from an integrated vertical-flow constructed wetland (IVCW) to treat agricultural domestic wastewater pollution in this study. The optimized intermittent micro-aeration conditions were a 20-min aeration time and 340-min non-aeration time, 3.9 m 3 h -1 aeration intensity, evenly distributed micro-aeration diffusers at the tank bottom, and an aeration period of every 6 h. Methane flux emission by intermittent micro-aeration was decreased by 60.7% under the optimized conditions. The average oxygen transfer efficiency was 26.73%. The control of CH 4 emission from IVCWs was most strongly influenced by the intermittent micro-aeration diffuser distribution, followed by aeration intensity, aeration time, and water depth. Scaling up of IVCWs is feasible in rural areas by using intermittent micro-aeration control as a mitigation measure for methane gas emissions for climate change.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor-Pashow, Kathryn M. L.; Jones, Daniel H.
A non-aqueous titration method has been used for quantifying the suppressor concentration in the MCU solvent hold tank (SHT) monthly samples since the Next Generation Solvent (NGS) was implemented in 2013. The titration method measures the concentration of the NGS suppressor (TiDG) as well as the residual tri-n-octylamine (TOA) that is a carryover from the previous solvent. As the TOA concentration has decreased over time, it has become difficult to resolve the TiDG equivalence point as the TOA equivalence point has moved closer. In recent samples, the TiDG equivalence point could not be resolved, and therefore, the TiDG concentration wasmore » determined by subtracting the TOA concentration as measured by semi-volatile organic analysis (SVOA) from the total base concentration as measured by titration. In order to improve the titration method so that the TiDG concentration can be measured directly, without the need for the SVOA data, a new method has been developed that involves spiking of the sample with additional TOA to further separate the two equivalence points in the titration. This method has been demonstrated on four recent SHT samples and comparison to results obtained using the SVOA TOA subtraction method shows good agreement. Therefore, it is recommended that the titration procedure be revised to include the TOA spike addition, and this to become the primary method for quantifying the TiDG.« less
Efficient system interrupt concept design at the microprogramming level
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fakharzadeh, M.M.
1989-01-01
Over the past decade the demand for high speed super microcomputers has been tremendously increased. To satisfy this demand many high speed 32-bit microcomputers have been designed. However, the currently available 32-bit systems do not provide an adequate solution to many highly demanding problems such as in multitasking, and in interrupt driven applications, which both require context switching. Systems for these purposes usually incorporate sophisticated software. In order to be efficient, a high end microprocessor based system must satisfy stringent software demands. Although these microprocessors use the latest technology in the fabrication design and run at a very high speed,more » they still suffer from insufficient hardware support for such applications. All too often, this lack also is the premier cause of execution inefficiency. In this dissertation a micro-programmable control unit and operation unit is considered in an advanced design. An automaton controller is designed for high speed micro-level interrupt handling. Different stack models are designed for the single task and multitasking environment. The stacks are used for storage of various components of the processor during the interrupt calls, procedure calls, and task switching. A universal (as an example seven port) register file is designed for high speed parameter passing, and intertask communication in the multitasking environment. In addition, the register file provides a direct path between ALU and the peripheral data which is important in real-time control applications. The overall system is a highly parallel architecture, with no pipeline and internal cache memory, which allows the designer to be able to predict the processor's behavior during the critical times.« less
Andy Jenkins Builds Applications Development For Lab-on-a-Chip
NASA Technical Reports Server (NTRS)
2004-01-01
Andy Jenkins, an engineer for the Lab on a Chip Applications Development program, helped build the Applications Development Unit (ADU-25), a one-of-a-kind facility for controlling and analyzing processes on chips with extreme accuracy. Pressure is used to cause fluids to travel through network of fluid pathways, or micro-channels, embossed on the chips through a process similar to the one used to print circuits on computer chips. To make customized chips for various applications, NASA has an agreement with the U.S. Army's Micro devices and Micro fabrication Laboratory at Redstone Arsenal in Huntsville, Alabama, where NASA's Marshall Space Flight Center (MSFC) is located. The Marshall Center team is also collaborating with scientists at other NASA centers and at universities to develop custom chip designs for many applications, such as studying how fluidic systems work in spacecraft and identifying microbes in self-contained life support systems. Chips could even be designed for use on Earth, such as for detecting deadly microbes in heating and air systems. (NASA/MSFC/D.Stoffer)
Sampling strategies exploiting multi-pumping flow systems.
Prior, João A V; Santos, João L M; Lima, José L F C
2003-04-01
In this work new strategies were exploited to implement multi-pumping flow systems relying on the utilisation of multiple devices that act simultaneously as sample-insertion, reagent-introduction, and solution-propelling units. The solenoid micro-pumps that were initially used as the only active elements of multi-pumping systems, and which were able to produce pulses of 3 to 25 microL, were replaced by syringe pumps with the aim of producing pulses between 1 and 4 microL. The performance of the developed flow system was assessed by using distinct sample-insertion strategies like single sample volume, merging zones, and binary sampling in the spectrophotometric determination of isoniazid in pharmaceutical formulations upon reaction with 1,2-naphthoquinone-4-sulfonate, in alkaline medium. The results obtained showed that enhanced sample/reagent mixing could be obtained with binary sampling and by using a 1 microL per step pump, even in limited dispersion conditions. Moreover, syringe pumps produce very reproducible flowing streams and are easily manipulated and controlled by a computer program, which is greatly simplified since they are the only active manifold component. Linear calibration plots up to 18.0 microg mL(-1), with a relative standard deviation of less than 1.48% (n=10) and a throughput of about 20 samples per hour, were obtained.
Theoretical and experimental analysis of AlGaInP micro-LED array with square-circle anode
NASA Astrophysics Data System (ADS)
Tian, Chao; Wang, Weibiao; Liang, Jingqiu; Liang, Zhongzhu; Qin, Yuxin; Lv, Jinguang
2015-04-01
An array of 320 × 240 micro-light-emitting diodes (micro-LEDs) based on an AlGaInP epitaxial wafer and with a unit size of 100 µm×100 µm was designed and fabricated. The optimum width of the isolation groove between adjacent light-emitting units was determined based on a compromise between full isolation of each LED and maximization of the light emitting area, and was found to be 20 µm. The grooves were filled with a mixed Si granule-polyurethane composite medium, because this type of insulating material can reflect part of the emitted light from the sidewall to the window layer in each light-emitting unit, and could thus improve lighting output efficiency. The 10-µm-wide square-circle anode was designed to increase the light emitting area while simultaneously being simple to fabricate. The device current used was in the 0.42-1.06 mA range to guarantee internal quantum efficiency of more than 85%, with a corresponding voltage range of 2-2.3 V. The layered temperature distribution in a single unit was simulated under a drive voltage of 2.2 V, and the maximum device temperature was 341 K. The micro-opto-electro-mechanical systems (MOEMS) technology-based fabrication process, experimental images of the device and device test results are presented here.
Theoretical and experimental analysis of AlGaInP micro-LED array with square-circle anode
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tian, Chao; University of Chinese Academy of Sciences, Beijing 100049; Wang, Weibiao, E-mail: wangwbcn@163.com
An array of 320 × 240 micro-light-emitting diodes (micro-LEDs) based on an AlGaInP epitaxial wafer and with a unit size of 100 µm×100 µm was designed and fabricated. The optimum width of the isolation groove between adjacent light-emitting units was determined based on a compromise between full isolation of each LED and maximization of the light emitting area, and was found to be 20 µm. The grooves were filled with a mixed Si granule-polyurethane composite medium, because this type of insulating material can reflect part of the emitted light from the sidewall to the window layer in each light-emitting unit,more » and could thus improve lighting output efficiency. The 10-µm-wide square-circle anode was designed to increase the light emitting area while simultaneously being simple to fabricate. The device current used was in the 0.42–1.06 mA range to guarantee internal quantum efficiency of more than 85%, with a corresponding voltage range of 2–2.3 V. The layered temperature distribution in a single unit was simulated under a drive voltage of 2.2 V, and the maximum device temperature was 341 K. The micro-opto-electro-mechanical systems (MOEMS) technology-based fabrication process, experimental images of the device and device test results are presented here.« less
Micro-cogen AMTEC systems for residential and transportation opportunities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mital, R.; Rasmussen, J.R.; Hunt, T.
1998-07-01
This paper describes the design and anticipated performance of high efficiency AMTEC systems suitable for natural gas fired micro-cogeneration for residential and transportation applications. AMTEC systems have a relatively flat efficiency curve from a few tens of watts to several kilowatts. This unique quality of AMTEC makes it well suited for micro-cogen as opposed to other technologies, such as internal combustion (IC) engines, which lose efficiency at low power levels. AMTEC also offers additional advantages of high efficiency, high reliability, low noise and low emissions. Combustion heated AMTEC cogeneration systems can also be used in trucks and trailers to keepmore » the diesel engines and cabs warm, provide electrical power for charging the battery and maintain power to the electrical systems during stand down periods. A market study indicates that residential micro-cogen units should have a design generating capacity between 0.5--2 kW. AMTEC systems producing 500 W net electric power have been designed and are presently being built. A 350 W prototype unit is being manufactured for a European firm as a trial unit for central heat and power from a home furnace. Modular one kilowatt units are also being designed that will allow combination into multi-kilowatt systems. The results of feasibility studies focused on price/Watt, efficiency, noise, emission, vibrations, expected lifetime and maintenance cost are also presented in this paper.« less
NASA Astrophysics Data System (ADS)
Karahara, Ichirou; Soga, Kouichi; Hoson, Takayuki; Kamisaka, Seiichiro; Yano, Sachiko; Shimazu, Toru; Tamaoki, Daisuke; Tanigaki, Fumiaki; Kasahara, Haruo; Yashiro, Umi; Suto, Takamichi; Yamaguchi, Takashi; Kasahara, Hirokazu
2012-07-01
Gravity is an important environmental factors for growth and development of plants throughout their life cycle. We have designed an experiment, which is called Space Seed, to examine the effects of microgravity on the seed to seed life cycle of plants. We have carried out this experiment using a newly developed apparatus, which is called the Plant Experiment Unit (PEU) and installed in the Cell Biology Experiment Facility (CBEF) onboard International Space Station (ISS). The CBEF is equipped with a turntable generating artificial gravity to perform 1-G control experiment as well as micro-G experiment on board. Arabidopsis thaliana seeds sown on dry rockwool in PEUs were transported from Kennedy Space Center to the ISS Kibo module by Space Shuttle Discovery in STS-128 mission. This experiment was started on Sep. 10, 2009 and terminated on Nov. 11, 2009. Arabidopsis seeds successfully germinated, and the plants passed through both vegetative and reproductive processes, such as formation of rosette leaves, bolting of inflorescence stems, flowering, formation of siliques and seeds. Vegetative and reproductive growth were compared among micro-G plants, 1-G control, and the ground control.
Controlling Variable Emittance (MEMS) Coatings for Space Applications
NASA Technical Reports Server (NTRS)
Farrar, D.; Schneider, W.; Osiander, R.; Champion, J. L.; Darrin, A. G.; Douglas, Donya; Swanson, Ted D.
2003-01-01
Small spacecraft, including micro and nanosats, as they are envisioned for future missions, will require an alternative means to achieve thermal control due to their small power and mass budgets. One of the proposed alternatives is Variable Emittance (Vari-E) Coatings for spacecraft radiators. Space Technology-5 (ST-5) is a technology demonstration mission through NASA Goddard Space Flight Center (GSFC) that will utilize Vari-E Coatings. This mission involves a constellation of three (3) satellites in a highly elliptical orbit with a perigee altitude of approximately 200 kilometers and an apogee of approximately 38,000 kilometers. Such an environment will expose the spacecraft to a wide swing in the thermal and radiation environment of the earth's atmosphere. There are three (3) different technologies associated with this mission. The three technologies are electrophoretic, electrochromic, and Micro ElectroMechanical Systems (MEMS). The ultimate goal is to make use of Van-E coatings, in order to achieve various levels of thermal control. The focus of this paper is to highlight the Vari-E Coating MEMS instrument, with an emphasis on the Electronic Control Unit responsible for operating the MEMS device. The Test & Evaluation approach, along with the results, is specific for application on ST-5, yet the information provides a guideline for future experiments and/or thermal applications on the exterior structure of a spacecraft.
Bates, Jonathan D; Davies, Kirk W
2017-10-01
Conifer control in sagebrush steppe of the western United States causes various levels of site disturbance influencing vegetation recovery and resource availability. The data set presented in this article include growing season availability of soil micronutrients and levels of total soil carbon, organic matter, and N spanning a six year period following western juniper ( Juniperus occidentalis spp. occidentalis ) reduction by mechanical cutting and prescribed fire of western juniper woodlands in southeast Oregon. These data can be useful to further evaluate the impacts of conifer woodland reduction to soil resources in sagebrush steppe plant communities.
Feedforward hysteresis compensation in trajectory control of piezoelectrically-driven nanostagers
NASA Astrophysics Data System (ADS)
Bashash, Saeid; Jalili, Nader
2006-03-01
Complex structural nonlinearities of piezoelectric materials drastically degrade their performance in variety of micro- and nano-positioning applications. From the precision positioning and control perspective, the multi-path time-history dependent hysteresis phenomenon is the most concerned nonlinearity in piezoelectric actuators to be analyzed. To realize the underlying physics of this phenomenon and to develop an efficient compensation strategy, the intelligent properties of hysteresis with the effects of non-local memories are discussed. Through performing a set of experiments on a piezoelectrically-driven nanostager with high resolution capacitive position sensor, it is shown that for the precise prediction of hysteresis path, certain memory units are required to store the previous hysteresis trajectory data. Based on the experimental observations, a constitutive memory-based mathematical modeling framework is developed and trained for the precise prediction of hysteresis path for arbitrarily assigned input profiles. Using the inverse hysteresis model, a feedforward control strategy is then developed and implemented on the nanostager to compensate for the system everpresent nonlinearity. Experimental results demonstrate that the controller remarkably eliminates the nonlinear effect if memory units are sufficiently chosen for the inverse model.
Seki, K; Narusawa, M
1996-05-06
To examine the factors affecting the control of human motor units, rate coding strategies of the motor units were investigated in upper limb and intrinsic hand muscles during voluntary isometric contraction of steady force levels up to 80% of maximal voluntary contraction. Numerous spike trains from single motor units were recorded from the m. first dorsal interosseous (FDI) and the m. biceps brachii (BB) of eight human subjects by means of tungsten micro-electrodes, and the mean firing rate (MFR) was calculated for each subject and inter-individual comparisons made. The MFRs of the FDI were larger than that of the BB at the higher force level, and substantial differences were not found between these muscles at the lower force level. The slope of the linear regression line of MFRs vs. exerted forces for the FDI was more than twice that for the BB. Therefore, isometric force control of the FDI depends more on the rate coding strategy. The difference in rate coding between the FDI and BB motor units may be determined by factors other than muscle fiber composition, because both muscles are known to possess a similar composition of fiber types. Possible mechanisms underlying these characteristics of rate coding strategy are considered in this report.
Won, Tae-Hee; Park, Sung-Joon
2012-01-01
For decades, underwater acoustic communication has been restricted to the point-to-point long distance applications such as deep sea probes and offshore oil fields. For this reason, previous acoustic modems were typically characterized by high data rates and long working ranges at the expense of large size and high power consumption. Recently, as the need for underwater wireless sensor networks (UWSNs) has increased, the research and development of compact and low-power consuming communication devices has become the focus. From the consideration that the requisites of acoustic modems for UWSNs are low power consumption, omni-directional beam pattern, low cost and so on, in this paper, we design and implement an omni-directional underwater acoustic micro-modem satisfying these requirements. In order to execute fast digital domain signal processing and support flexible interfaces with other peripherals, an ARM Cortex-M3 is embedded in the micro-modem. Also, for the realization of small and omni-directional properties, a spherical transducer having a resonant frequency of 70 kHz and a diameter of 34 mm is utilized for the implementation. Physical layer frame format and symbol structure for efficient packet-based underwater communication systems are also investigated. The developed acoustic micro-modem is verified analytically and experimentally in indoor and outdoor environments in terms of functionality and performance. Since the modem satisfies the requirements for use in UWSNs, it could be deployed in a wide range of applications requiring underwater acoustic communication.
Delivery of Colloid Micro-Newton Thrusters for the Space Technology 7 Mission
NASA Technical Reports Server (NTRS)
Ziemer, John K.; Randolph, Thomas M.; Franklin, Garth W.; Hruby, Vlad; Spence, Douglas; Demmons, Nathaniel; Roy, Thomas; Ehrbar, Eric; Zwahlen, Jurg; Martin, Roy;
2008-01-01
Two flight-qualified clusters of four Colloid Micro-Newton Thruster (CMNT) systems have been delivered to the Jet Propulsion Laboratory (JPL). The clusters will provide precise spacecraft control for the drag-free technology demonstration mission, Space Technology 7 (ST7). The ST7 mission is sponsored by the NASA New Millennium Program and will demonstrate precision formation flying technologies for future missions such as the Laser Interferometer Space Antenna (LISA) mission. The ST7 disturbance reduction system (DRS) will be on the ESA LISA Pathfinder spacecraft using the European gravitational reference sensor (GRS) as part of the ESA LISA Technology Package (LTP). Developed by Busek Co. Inc., with support from JPL in design and testing, the CMNT has been developed over the last six years into a flight-ready and flight-qualified microthruster system, the first of its kind. Recent flight-unit qualification tests have included vibration and thermal vacuum environmental testing, as well as performance verification and acceptance tests. All tests have been completed successfully prior to delivery to JPL. Delivery of the first flight unit occurred in February of 2008 with the second unit following in May of 2008. Since arrival at JPL, the units have successfully passed through mass distribution, magnetic, and EMI/EMC measurements and tests as part of the integration and test (I&T) activities including the integrated avionics unit (IAU). Flight software sequences have been tested and validated with the full flight DRS instrument successfully to the extent possible in ground testing, including full functional and 72 hour autonomous operations tests. Delivery of the cluster assemblies along with the IAU to ESA for integration into the LISA Pathfinder spacecraft is planned for the summer of 2008 with a planned launch and flight demonstration in late 2010.
Effects of methyltestosterone on insulin secretion and sensitivity in women.
Diamond, M P; Grainger, D; Diamond, M C; Sherwin, R S; Defronzo, R A
1998-12-01
The frequent coexistence of hyperandrogenism and insulin resistance is well established; however, whether a cause and effect relationship exists remains to be established. In this study we tested the hypothesis that short-term androgen administered to women would induce insulin resistance. To test this hypothesis, regularly menstruating, nonobese women were studied before and during methyltestosterone administration (5 mg tid for 10-12 days) by the hyperglycemic (n=8) and euglycemic, hyperinsulinemic (n=7) clamp techniques. Short-term methyltestosterone administration had no significant effects on the fasting levels of glucose, insulin, c-peptide, glucagon, or glucose turnover. During the hyperglycemic clamp studies, the mean glucose level during the final hour was 203+/-2 and 201+/-1 mg/dL in the methyltestosterone and control studies, respectively. The insulin response to this hyperglycemic challenge was slightly but not significantly greater during methyltestosterone treatment (first phase 59+/-8 vs. 50+/-8 microU/mL in controls; second phase 74+/-9 vs. 67+/-9 microU/mL in controls; total insulin response 133+/-16 vs. 117+/-15 microU/mL in controls). In spite of this, glucose uptake was reduced from the control study value of 10.96+/-1.11 to 7.3+/-0.70 mg/kg/min by methyltestosterone (P < 0.05). The ratio of glucose uptake per unit of insulin was also significantly reduced from a control study value of 14.3+/-1.4 to 9.4+/-1.3 mg/kg/min per microU/mL x 100 during methyltestosterone administration. In the euglycemic hyperinsulinemic clamp studies, insulin was infused at rates of 0.25 and 1.0 mU/kg/min to achieve insulin levels of approximately 25 and 68 microU/mL, respectively. During low-dose insulin infusion, rates of endogenous hepatic glucose production were equivalently suppressed from basal values of 2.37+/-0.29 and 2.40+/-0.27 mg/kg/min to 0.88+/-0.25 and 0.77+/-0.26 mg/kg/min in the methyltestesterone and control studies respectively. Whole body glucose uptake during low-dose insulin infusion was minimally affected. During the high-dose insulin infusion, endogenous hepatic glucose production was nearly totally suppressed in both groups. However, whole body glucose uptake was reduced from the control value of 6.11+/-0.49 mg/kg/min to 4.93+/-0.44 mg/kg/min during methyltestosterone administration (P < 0.05). Our data demonstrate that androgen excess leads to the development of insulin resistance during both hyperglycemic and euglycemic hyperinsulinemia. These findings provide direct evidence for a relationship between hyperandrogenemia and insulin resistance, and its associated risk factors for cardiovascular disease.
NASA Technical Reports Server (NTRS)
Yang, Ren; Feeback, Daniel L.; Wang, Wanjun
2004-01-01
This paper details a novel three-dimensional (3D) hydro-focusing micro cell sorter for micro flow cytometry applications. The unit was microfabricated by means of SU-8 3D lithography. The 3D microstructure for coaxial sheathing was designed, microfabricated, and tested. Three-dimensional hydro-focusing capability was demonstrated with an experiment to sort labeled tanned sheep erythrocytes (red blood cells). This polymer hydro-focusing microstructure is easily microfabricated and integrated with other polymer microfluidic structures.
Using SDI-12 with ST microelectronics MCU's
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saari, Alexandra; Hinzey, Shawn Adrian; Frigo, Janette Rose
2015-09-03
ST Microelectronics microcontrollers and processors are readily available, capable and economical processors. Unfortunately they lack a broad user base like similar offerings from Texas Instrument, Atmel, or Microchip. All of these devices could be useful in economical devices for remote sensing applications used with environmental sensing. With the increased need for environmental studies, and limited budgets, flexibility in hardware is very important. To that end, and in an effort to increase open support of ST devices, I am sharing my teams' experience in interfacing a common environmental sensor communication protocol (SDI-12) with ST devices.
Huston, Robert K; Christensen, J Mark; Alshahrani, Sultan M; Mohamed, Sumeia M; Clark, Sara M; Nason, Jeffrey A; Wu, Ying Xing
2015-01-01
Previous studies of compatibility of calcium chloride (CaCl2) and phosphates have not included particle counts in the range specified by the United States Pharmacopeia. Micro-flow imaging techniques have been shown to be comparable to light obscuration when determining particle count and size in pharmaceutical solutions. The purpose of this study was to do compatibility testing for parenteral nutrition (PN) solutions containing CaCl2 using dynamic light scattering and micro-flow imaging techniques. Solutions containing TrophAmine (Braun Medical Inc, Irvine, CA), CaCl2, and sodium phosphate (NaPhos) were compounded with and without cysteine. All solutions contained standard additives to neonatal PN solutions including dextrose, trace metals, and electrolytes. Control solutions contained no calcium or phosphate. Solutions were analyzed for particle size and particle count. Means of Z-average particle size and particle counts of controls were determined. Study solutions were compared to controls and United States Pharmacopeia (USP) Chapter 788 guidelines. The maximum amount of Phos that was compatible in solutions that contained at least 10 mmol/L of Ca in 2.5% amino acids (AA) was determined. Compatibility of these solutions was verified by performing analyses of 5 repeats of these solutions. Microscopic analyses of the repeats were also performed. Amounts of CaCl2 and NaPhos that were compatible in solutions containing 1.5%, 2%, 2.5%, and 3% AA were determined. The maximum amount of NaPhos that could be added to TrophAmine solutions of > = 2.5% AA containing at least 10 mmol/L of CaCl2 was 7.5 mmol/L. Adding 50 mg/dL of cysteine increased the amount of NaPhos that could be added to solutions containing 10 mmol/L of CaCl2 to 10 mmol/L. Calcium chloride can be added to neonatal PN solutions containing NaPhos in concentrations that can potentially provide an intravenous intake of adequate amounts of calcium and phosphorus.
Sensitivity enhancement in optical micro-tube resonator sensors via mode coupling
NASA Astrophysics Data System (ADS)
Ling, Tao; Guo, L. Jay
2013-07-01
A liquid filled, silica micro-tube with a low refractive index material inner-coating has been proposed and theoretically studied as a coupled micro-resonator sensor to greatly enhance biochemical sensor sensitivity. Its unique coupling phenomenon has been analyzed and utilized to boost the device's refractive index sensitivity to 967 nm/Refractive Index Unit (RIU). Through optimization of the coupling strength between the two micro-resonators, further improvement in refractive index sensitivity up to 1100 nm/RIU has been predicted. This mode coupling strategy allows us to design robust, thick-walled micro-tube sensors with ultra-high sensitivity which is useful in practical biochemical sensing applications.
Effect of healing time on bone-implant contact of orthodontic micro-implants: a histologic study.
Ramazanzadeh, Barat Ali; Fatemi, Kazem; Dehghani, Mahboobe; Mohtasham, Nooshin; Jahanbin, Arezoo; Sadeghian, Hamed
2014-01-01
Objectives. This study aimed to evaluate the effect of immediate and delayed loading of orthodontic micro-implants on bone-implant contact. Materials and Methods. Sixty four micro-implants were implanted in dog's jaw bone. The micro-implants were divided into loaded and unloaded (control) groups. The control group had two subgroups: four and eight weeks being implanted. The loaded group had two subgroups of immediate loading and delayed (after four weeks healing) loading. Loaded samples were subjected to 200g load for four weeks. After sacrificing the animals micro-implants and surrounding tissues were observed histologically. Bone-implant contact ratios (BIC) were calculated and different groups' results were compared by three-way ANOVA. Results. Mean survival rate was 96.7% in general. Survival rates were 96.7%, 94.4% and 100% for control, immediate and delayed loaded groups, respectively. BIC values were not significantly different in loaded and control groups, immediate and delayed loading groups, and pressure and tension sides. Mandibular micro-implants had significantly higher BIC than maxillary ones in immediate loading, 4-weeks control, and 8-weeks control groups (P = 0.021, P = 0.009, P = 0.003, resp.). Conclusion Immediate or delayed loading of micro-implants in dog did not cause significant difference in Bone-implant contact which could be concluded that healing time had not significant effect on micro-implant stability.
Effect of Healing Time on Bone-Implant Contact of Orthodontic Micro-Implants: A Histologic Study
Ramazanzadeh, Barat Ali; Fatemi, Kazem; Dehghani, Mahboobe; Mohtasham, Nooshin; Jahanbin, Arezoo; Sadeghian, Hamed
2014-01-01
Objectives. This study aimed to evaluate the effect of immediate and delayed loading of orthodontic micro-implants on bone-implant contact. Materials and Methods. Sixty four micro-implants were implanted in dog's jaw bone. The micro-implants were divided into loaded and unloaded (control) groups. The control group had two subgroups: four and eight weeks being implanted. The loaded group had two subgroups of immediate loading and delayed (after four weeks healing) loading. Loaded samples were subjected to 200g load for four weeks. After sacrificing the animals micro-implants and surrounding tissues were observed histologically. Bone-implant contact ratios (BIC) were calculated and different groups' results were compared by three-way ANOVA. Results. Mean survival rate was 96.7% in general. Survival rates were 96.7%, 94.4% and 100% for control, immediate and delayed loaded groups, respectively. BIC values were not significantly different in loaded and control groups, immediate and delayed loading groups, and pressure and tension sides. Mandibular micro-implants had significantly higher BIC than maxillary ones in immediate loading, 4-weeks control, and 8-weeks control groups (P = 0.021, P = 0.009, P = 0.003, resp.). Conclusion Immediate or delayed loading of micro-implants in dog did not cause significant difference in Bone-implant contact which could be concluded that healing time had not significant effect on micro-implant stability. PMID:25006463
Fabrication of micro-lens array on convex surface by meaning of micro-milling
NASA Astrophysics Data System (ADS)
Zhang, Peng; Du, Yunlong; Wang, Bo; Shan, Debin
2014-08-01
In order to develop the application of the micro-milling technology, and to fabricate ultra-precision optical surface with complex microstructure, in this paper, the primary experimental research on micro-milling complex microstructure array is carried out. A complex microstructure array surface with vary parameters is designed, and the mathematic model of the surface is set up and simulated. For the fabrication of the designed microstructure array surface, a micro three-axis ultra-precision milling machine tool is developed, aerostatic guideway drove directly by linear motor is adopted in order to guarantee the enough stiffness of the machine, and novel numerical control strategy with linear encoders of 5nm resolution used as the feedback of the control system is employed to ensure the extremely high motion control accuracy. With the help of CAD/CAM technology, convex micro lens array on convex spherical surface with different scales on material of polyvinyl chloride (PVC) and pure copper is fabricated using micro tungsten carbide ball end milling tool based on the ultra-precision micro-milling machine. Excellent nanometer-level micro-movement performance of the axis is proved by motion control experiment. The fabrication is nearly as the same as the design, the characteristic scale of the microstructure is less than 200μm and the accuracy is better than 1μm. It prove that ultra-precision micro-milling technology based on micro ultra-precision machine tool is a suitable and optional method for micro manufacture of microstructure array surface on different kinds of materials, and with the development of micro milling cutter, ultraprecision micro-milling complex microstructure surface will be achieved in future.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jain, V.; Shah, H.; Bannochie, C. J.
Mercury (Hg) in the Savannah River Site Liquid Waste System (LWS) originated from decades of canyon processing where it was used as a catalyst for dissolving the aluminum cladding of reactor fuel. Approximately 60 metric tons of mercury is currently present throughout the LWS. Mercury has long been a consideration in the LWS, from both hazard and processing perspectives. In February 2015, a Mercury Program Team was established at the request of the Department of Energy to develop a comprehensive action plan for long-term management and removal of mercury. Evaluation was focused in two Phases. Phase I activities assessed themore » Liquid Waste inventory and chemical processing behavior using a system-by-system review methodology, and determined the speciation of the different mercury forms (Hg+, Hg++, elemental Hg, organomercury, and soluble versus insoluble mercury) within the LWS. Phase II activities are building on the Phase I activities, and results of the LWS flowsheet evaluations will be summarized in three reports: Mercury Behavior in the Salt Processing Flowsheet (i.e. this report); Mercury Behavior in the Defense Waste Processing Facility (DWPF) Flowsheet; and Mercury behavior in the Tank Farm Flowsheet (Evaporator Operations). The evaluation of the mercury behavior in the salt processing flowsheet indicates, inter alia, the following: (1) In the assembled Salt Batches 7, 8 and 9 in Tank 21, the total mercury is mostly soluble with methylmercury (MHg) contributing over 50% of the total mercury. Based on the analyses of samples from 2H Evaporator feed and drop tanks (Tanks 38/43), the source of MHg in Salt Batches 7, 8 and 9 can be attributed to the 2H evaporator concentrate used in assembling the salt batches. The 2H Evaporator is used to evaporate DWPF recycle water. (2) Comparison of data between Tank 21/49, Salt Solution Feed Tank (SSFT), Decontaminated Salt Solution Hold Tank (DSSHT), and Tank 50 samples suggests that the total mercury as well as speciated forms in the assembled salt batches in Tanks 21/49 pass through the Actinide Removal Process (ARP) / Modular Caustic Side Solvent Extraction Unit (MCU) process to Tank 50 with no significant change in the mercury chemistry. (3) In Tank 50, Decontaminated Salt Solution (DSS) from ARP/MCU is the major contributor to the total mercury including MHg. (4) Speciation analyses of TCLP leached solutions of the grout samples prepared from Tank 21, as well as Tank 50 samples, show the majority of the mercury released in the solution is MHg.« less
The Impact Of The MCU Life Extension Solvent On Sludge Batch 8 Projected Operating Windows
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peeler, D. K.; Edwards, T. B.
2013-06-26
As a part of the Actinide Removal Process (ARP)/Modular Caustic Side Solvent Extraction Unit (MCU) Life Extension Project, a next generation solvent (NGS) and a new strip acid will be deployed. The strip acid will be changed from dilute nitric acid to dilute boric acid (0.01 M). Because of these changes, experimental testing or evaluations with the next generation solvent are required to determine the impact of these changes (if any) to Chemical Process Cell (CPC) activities, glass formulation strategies, and melter operations at the Defense Waste Processing Facility (DWPF). The introduction of the dilute (0.01 M) boric acid streammore » into the DWPF flowsheet has a potential impact on glass formulation and frit development efforts since B203 is a major oxide in frits developed for DWPF. Prior knowledge of this stream can be accounted for during frit development efforts but that was not the case for Sludge Batch 8 (SB8). Frit 803 has already been recommended and procured for SB8 processing; altering the frit to account for the incoming boron from the strip effluent (SE) is not an option for SB8. Therefore, the operational robustness of Frit 803 to the introduction of SE including its compositional tolerances (i.e., up to 0.0125M boric acid) is of interest and was the focus of this study. The primary question to be addressed in the current study was: What is the impact (if any) on the projected operating windows for the Frit 803 - SB8 flowsheet to additions of B203 from the SE in the Sludge Receipt and Adjustment Tank (SRAT)? More specifically, will Frit 803 be robust to the potential compositional changes occurring in the SRAT due to sludge variation, varying additions of ARP and/or the introduction of SE by providing access to waste loadings (WLs) of interest to DWPF? The Measurement Acceptability Region (MAR) results indicate there is very little, if any, impact on the projected operating windows for the Frit 803 - SB8 system regardless of the presence or absence of ARP and SE (up to 2 wt% B203 contained in the SRAT and up to 2000 gallons of ARP). It should be noted that 0.95 wt% B203 is the nominal projected concentration in the SRAT based on a 0.0125M boric acid flowsheet with 70,000 liters of SE being added to the SRAT.« less
The study on the control strategy of micro grid considering the economy of energy storage operation
NASA Astrophysics Data System (ADS)
Ma, Zhiwei; Liu, Yiqun; Wang, Xin; Li, Bei; Zeng, Ming
2017-08-01
To optimize the running of micro grid to guarantee the supply and demand balance of electricity, and to promote the utilization of renewable energy. The control strategy of micro grid energy storage system is studied. Firstly, the mixed integer linear programming model is established based on the receding horizon control. Secondly, the modified cuckoo search algorithm is proposed to calculate the model. Finally, a case study is carried out to study the signal characteristic of micro grid and batteries under the optimal control strategy, and the convergence of the modified cuckoo search algorithm is compared with others to verify the validity of the proposed model and method. The results show that, different micro grid running targets can affect the control strategy of energy storage system, which further affect the signal characteristics of the micro grid. Meanwhile, the convergent speed, computing time and the economy of the modified cuckoo search algorithm are improved compared with the traditional cuckoo search algorithm and differential evolution algorithm.
Optimal Micro-Jet Flow Control for Compact Air Vehicle Inlets
NASA Technical Reports Server (NTRS)
Anderson, Bernhard H.; Miller, Daniel N.; Addington, Gregory A.; Agrell, Johan
2004-01-01
The purpose of this study on micro-jet secondary flow control is to demonstrate the viability and economy of Response Surface Methodology (RSM) to optimally design micro-jet secondary flow control arrays, and to establish that the aeromechanical effects of engine face distortion can also be included in the design and optimization process. These statistical design concepts were used to investigate the design characteristics of "low mass" micro-jet array designs. The term "low mass" micro-jet may refers to fluidic jets with total (integrated) mass flow ratios between 0.10 and 1.0 percent of the engine face mass flow. Therefore, this report examines optimal micro-jet array designs for compact inlets through a Response Surface Methodology.
NASA Astrophysics Data System (ADS)
Ye, Bo; Zhang, Wei; Sun, Zhen-jun; Guo, Lin; Deng, Chao; Chen, Ya-qi; Zhang, Hong-hai; Liu, Sheng
2015-12-01
In this paper, the authors propose rotating an external permanent magnet (EPM) to manipulate the synchronous rotation of a magnetic spiral-type wireless capsule endoscope (WCE), and the synchronous rotation of the WCE is converted to its translational motion in intestinal tract. In order to preliminarily verify the feasibility of this method, a handheld actuator (HA) controlled by micro controller unit, a magnetic spiral-type WCE and a bracket were fabricated, theoretical analysis and simulations about the control distance of this method were performed, and in ex-vivo tests were examined in porcine small intestine to verify the control distance and control performances of this method. It was demonstrated that this method showed good performances in controlling the translational motion of the magnetic spiral-type WCE, and this method has great potential to be used in clinical application.
Intelligent Control of Micro Grid: A Big Data-Based Control Center
NASA Astrophysics Data System (ADS)
Liu, Lu; Wang, Yanping; Liu, Li; Wang, Zhiseng
2018-01-01
In this paper, a structure of micro grid system with big data-based control center is introduced. Energy data from distributed generation, storage and load are analized through the control center, and from the results new trends will be predicted and applied as a feedback to optimize the control. Therefore, each step proceeded in micro grid can be adjusted and orgnized in a form of comprehensive management. A framework of real-time data collection, data processing and data analysis will be proposed by employing big data technology. Consequently, a integrated distributed generation and a optimized energy storage and transmission process can be implemented in the micro grid system.
Tracking Control and System Development for Laser-Driven Micro-Vehicles
NASA Astrophysics Data System (ADS)
Kajiwara, Itsuro; Hoshino, Kentaro; Hara, Shinji; Shiokata, Daisuke; Yabe, Takashi
The purpose of this paper is to design a control system for an integrated laser propulsion/tracking system to achieve continuous motion and control of laser-driven micro-vehicles. Laser propulsion is significant in achieving miniature and light micro-vehicles. A laser-driven micro-airplane has been studied using a paper airplane and YAG laser, resulting in successful gliding of the airplane. High-performance laser tracking control is required to achieve continuous flight. This paper presents a control design strategy based on the generalized Kalman-Yakubovic-Popov lemma to achieve this requirement. Experiments have been carried out to evaluate the performance of the integrated laser propulsion/tracking system.
Reinsurance of health insurance for the informal sector.
Dror, D. M.
2001-01-01
Deficient financing of health services in low-income countries and the absence of universal insurance coverage leaves most of the informal sector in medical indigence, because people cannot assume the financial consequences of illness. The role of communities in solving this problem has been recognized, and many initiatives are under way. However, community financing is rarely structured as health insurance. Communities that pool risks (or offer insurance) have been described as micro-insurance units. The sources of their financial instability and the options for stabilization are explained. Field data from Uganda and the Philippines, as well as simulated situations, are used to examine the arguments. The article focuses on risk transfer from micro-insurance units to reinsurance. The main insight of the study is that when the financial results of micro-insurance units can be estimated, they can enter reinsurance treaties and be stabilized from the first year. The second insight is that the reinsurance pool may require several years of operation before reaching cost neutrality. PMID:11477971
A parallel strategy for predicting the secondary structure of polycistronic microRNAs.
Han, Dianwei; Tang, Guiliang; Zhang, Jun
2013-01-01
The biogenesis of a functional microRNA is largely dependent on the secondary structure of the microRNA precursor (pre-miRNA). Recently, it has been shown that microRNAs are present in the genome as the form of polycistronic transcriptional units in plants and animals. It will be important to design efficient computational methods to predict such structures for microRNA discovery and its applications in gene silencing. In this paper, we propose a parallel algorithm based on the master-slave architecture to predict the secondary structure from an input sequence. We conducted some experiments to verify the effectiveness of our parallel algorithm. The experimental results show that our algorithm is able to produce the optimal secondary structure of polycistronic microRNAs.
Evaluating the efficiency of humic acid to remove micro-organisms from denture base material.
Meriç, Gökçe; Güvenir, Meryem; Süer, Kaya
2016-09-01
To evaluate the efficiency of humic acid substances on removing micro-organisms from denture base materials. Old denture wearer needs effective, easy-use and safe denture-cleaning material. Square-shaped, heat-polymerised acrylic resin specimens (n = 550) were prepared and divided into five groups (n = 110 for each) corresponding to the microbial contamination (Candida albicans, Staphylococcus aureus, Bacillus cereus, Enterococcus faecalis, Pseudomonas aeruginosa). Contaminated specimens were randomly assigned to the application of five different denture-cleaning agents as follows (n = 20 for each): Kloroben, Corsodyl, Steradent, Corega, experimental solution with humic acid. Ten specimens were assessed as an experimental control carried out simultaneously for the treatment groups for each micro-organism. It was divided into two groups: negative control and positive control (n = 5 for each). All acrylic specimens were incubated 37°C for 24 h (for bacterial strains) and 37°C for 48 h (for yeast strains). After incubation period, all brain-heart infusion broths (BHI) which contain disinfectant acrylic specimens were cultured on 5% sheep blood agar (for bacteria) and Sabouraud dextrose agar (SDA) for yeast using loop. The numbers of colony-forming units per millilitre (CFU/ml) were calculated. The results were analysed by Mann-Whitney U-test and Kruskal-Wallis tests (p = 0.05). Corsodyl and Kloroben completely eliminated the adherence of all investigated micro-organisms (100%) and showed the highest removal activity compared with other cleaning agents (p < 0.05). There was no statistically significant difference between Corsodyl and Kloroben (p ≥ 0.05), and there was no statistically significant difference between Corega, Steradent and experimental solution (p ≥ 0.05). Humic acid could be used as an alternative 'natural' solution for denture-cleaning agent. © 2014 John Wiley & Sons A/S and The Gerodontology Association. Published by John Wiley & Sons Ltd.
Dobrunz, L E; Backx, P H; Yue, D T
1995-01-01
We have developed a novel method for measuring steady-state force-[Ca2+]i relations in isolated, membrane-intact rat trabeculae that are microinjected with Fura-2 salt. Twitches are markedly slowed after inhibition of phasic Ca2+ release and uptake from the sarcoplasmic reticulum by addition of cyclopiazonic acid and ryanodine. During relaxation of slowed twitches, force and [Ca2+]i trace a common trajectory in plots of force versus [Ca2+]i, despite very different histories of contraction. The common trajectory thereby provides a high resolution determination of the steady-state relation between force and [Ca2+]i. Using this method, we show that 1 microM isoproterenol, a beta-adrenergic agonist, causes a rightward shift (Hill function K1/2 increased from 0.39 +/- 0.07 microM to 0.82 +/- 0.23 microM, p < 0.02, n = 6) and a decreased slope (nH decreased from 5.4 +/- 1.1 to 4.0 +/- 1.4, p < 0.02) of the steady-state force-[Ca2+]i curve, with no change in maximal force (Fmax = 99.2 +/- 2.2% of control). In contrast, 2 microM EMD 53998, a racemic thiadiazinone derivative, causes a leftward shift (K1/2 decreased from 0.42 +/- 0.02 microM to 0.30 +/- 0.06 microM, p < 0.02, n = 4) with no change in slope of the steady-state force-[Ca2+]i curve, accompanied by a modest increase in maximal force (Fmax = 107.1 +/- 4.6% of control, p < 0.02). To gain mechanistic insight into these modulatory events, we developed a simple model of cooperative thin filament activation that predicts steady-state force-[Ca2+]i relationships. Model analysis suggests that isoproterenol decreases cooperativity arising from nearest-neighbor interactions between regulatory units on the thin filament, without change in the equilibrium constant for Ca2+ binding. In contrast, the effects of EMD 53998 are consistent with an increase in the affinity of strong-binding cross-bridges, without change in either the affinity of troponin C for Ca2+ or cooperative interactions. PMID:7669896
Generation of Micropatterned Substrates Using Micro Photopatterning
Doyle, Andrew D.
2010-01-01
Micro photopatterning (µPP) has been developed to rapidly test and generate different patterns for extracellular matrix adsorption without being hindered with the process of making physical stamps through nanolithography techniques. It uses two-photon excitation guided through a point-scanning confocal microscope to locally photoablate poly(vinyl) alcohol (PVA) thin films in user-defined computer-controlled patterns. PVA thin films are ideal for surface blocking, being hydrophilic substrates that deter protein adsorption and cell attachment. Because gold substrates are not used during µPP, all live-cell fluorescent imaging techniques including total internal reflection fluorescence microscopy of GFP–linked proteins can be performed with minimal loss of fluorescence signal. Furthermore, because µPP does not require physical stamps for pattern generation, multiple ECMs or other proteins can be localized within microns of each other. This unit details the setup of µPP as well as giving troubleshooting techniques. PMID:20013752
Simulation Based Exploration of Critical Zone Dynamics in Intensively Managed Landscapes
NASA Astrophysics Data System (ADS)
Kumar, P.
2017-12-01
The advent of high-resolution measurements of topographic and (vertical) vegetation features using areal LiDAR are enabling us to resolve micro-scale ( 1m) landscape structural characteristics over large areas. Availability of hyperspectral measurements is further augmenting these LiDAR data by enabling the biogeochemical characterization of vegetation and soils at unprecedented spatial resolutions ( 1-10m). Such data have opened up novel opportunities for modeling Critical Zone processes and exploring questions that were not possible before. We show how an integrated 3-D model at 1m grid resolution can enable us to resolve micro-topographic and ecological dynamics and their control on hydrologic and biogeochemical processes over large areas. We address the computational challenge of such detailed modeling by exploiting hybrid CPU and GPU computing technologies. We show results of moisture, biogeochemical, and vegetation dynamics from studies in the Critical Zone Observatory for Intensively managed Landscapes (IMLCZO) in the Midwestern United States.
NASA Astrophysics Data System (ADS)
Perrot, Eddy; Christophe, Bruno; Foulon, Bernard; Boulanger, Damien; Liorzou, Françoise; Lebat, Vincent
2013-04-01
The GRACE FO mission, led by the JPL (Jet Propulsion Laboratory), is an Earth-orbiting gravity mission, continuation of the GRACE mission, that will produce an accurate model of the Earth's gravity field variation providing global climatic data during five year at least. The mission involves two satellites in a loosely controlled tandem formation, with a micro-wave link measuring the inter-satellites distance variation. Non-uniformities in the distribution of the Earth's mass cause the distance between the two satellites to vary. This variation is measured to recover gravity, after substracting the non-gravitational contributors, as the residual drag. ONERA (the French Aerospace Lab) is developing and manufacturing electrostatic accelerometers measuring this residual drag applied on the satellites. The accelerometer is composed of two main parts: the Sensor Unit (including the Sensor Unit Mechanics and the Front-End Electronic Unit) and the Interface Control Unit. In the Accelerometer Core, located in the Sensor Unit Mechanics, the proof mass is levitated and maintained in a center of an electrode cage by electrostatic forces. Thus, any drag acceleration applied on the satellite involves a variation on the servo-controlled electrostatic suspension of the mass. The voltage on the electrodes providing this electrostatic force is the measurement output of the accelerometer. The impact of the accelerometer defaults (geometry, electronic and parasitic forces) leads to bias, misalignment and scale factor error, non-linearity and noise. Some of these accelerometer defaults are characterized by tests with micro-gravity pendulum bench and with drops in ZARM catapult. Besides, a thermal stability is needed for the accelerometer core and front-end electronics to avoid bias and scale factor variation. To reach this stability, the sensor unit is enclosed in a thermal box designed by Astrium, spacecraft manufacturer. The accelerometers are designed to endure mechanical excitation especially due to launching vibrations. As the measure must be accurate, no displacements or sliding must appear during excitations. The electrode cage is made of glass material (ULE), which is very critical, in particular due to the free motion of the proof-mass during the launch. Specific analysis on this part is realized to ensure mechanical behavior. The design of electrostatic accelerometer of the GRACE Follow-On mission benefits of the GRACE heritage, GOCE launched in 2009 and MICROSCOPE which will be launched in 2016, including some improvement to win in performance, in particular the thermal sensitivity of the measurements.
Retamal, Jaime; Bergamini, Bruno Curty; Carvalho, Alysson R; Bozza, Fernando A; Borzone, Gisella; Borges, João Batista; Larsson, Anders; Hedenstierna, Göran; Bugedo, Guillermo; Bruhn, Alejandro
2014-09-09
When alveoli collapse the traction forces exerted on their walls by adjacent expanded units may increase and concentrate. These forces may promote its re-expansion at the expense of potentially injurious stresses at the interface between the collapsed and the expanded units. We developed an experimental model to test the hypothesis that a local non-lobar atelectasis can act as a stress concentrator, contributing to inflammation and structural alveolar injury in the surrounding healthy lung tissue during mechanical ventilation. A total of 35 rats were anesthetized, paralyzed and mechanically ventilated. Atelectasis was induced by bronchial blocking: after five minutes of stabilization and pre-oxygenation with FIO2 = 1.0, a silicon cylinder blocker was wedged in the terminal bronchial tree. Afterwards, the animals were randomized between two groups: 1) Tidal volume (VT) = 10 ml/kg and positive end-expiratory pressure (PEEP) = 3 cmH2O (VT10/PEEP3); and 2) VT = 20 ml/kg and PEEP = 0 cmH2O (VT20/zero end-expiratory pressure (ZEEP)). The animals were then ventilated during 180 minutes. Three series of experiments were performed: histological (n = 12); tissue cytokines (n = 12); and micro-computed tomography (microCT; n = 2). An additional six, non-ventilated, healthy animals were used as controls. Atelectasis was successfully induced in the basal region of the lung of 26 out of 29 animals. The microCT of two animals revealed that the volume of the atelectasis was 0.12 and 0.21 cm3. There were more alveolar disruption and neutrophilic infiltration in the peri-atelectasis region than the corresponding contralateral lung (control) in both groups. Edema was higher in the peri-atelectasis region than the corresponding contralateral lung (control) in the VT20/ZEEP than VT10/PEEP3 group. The volume-to-surface ratio was higher in the peri-atelectasis region than the corresponding contralateral lung (control) in both groups. We did not find statistical difference in tissue interleukin-1β and cytokine-induced neutrophil chemoattractant-1 between regions. The present findings suggest that a local non-lobar atelectasis acts as a stress concentrator, generating structural alveolar injury and inflammation in the surrounding lung tissue.
Qi, Dianpeng; Liu, Yan; Liu, Zhiyuan; Zhang, Li; Chen, Xiaodong
2017-02-01
The rapid development of integrated electronics and the boom in miniaturized and portable devices have increased the demand for miniaturized and on-chip energy storage units. Currently thin-film batteries or microsized batteries are commercially available for miniaturized devices. However, they still suffer from several limitations, such as short lifetime, low power density, and complex architecture, which limit their integration. Supercapacitors can surmount all these limitations. Particularly for micro-supercapacitors with planar architectures, due to their unique design of the in-plane electrode finger arrays, they possess the merits of easy fabrication and integration into on-chip miniaturized electronics. Here, the focus is on the different strategies to design electrode finger arrays and the material engineering of in-plane micro-supercapacitors. It is expected that the advances in micro-supercapacitors with in-plane architectures will offer new opportunities for the miniaturization and integration of energy-storage units for portable devices and on-chip electronics. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Zhang, Peipei; Xia, Junfei; Luo, Sida
2018-01-01
Micro/nanoparticles have great potentials in biomedical applications, especially for drug delivery. Existing studies identified that major micro/nanoparticle features including size, shape, surface property and component materials play vital roles in their in vitro and in vivo applications. However, a demanding challenge is that most conventional particle synthesis techniques such as emulsion can only generate micro/nanoparticles with a very limited number of shapes (i.e., spherical or rod shapes) and have very loose control in terms of particle sizes. We reviewed the advanced manufacturing techniques for producing micro/nanoparticles with precisely defined characteristics, emphasizing the use of these well-controlled micro/nanoparticles for drug delivery applications. Additionally, to illustrate the vital roles of particle features in therapeutic delivery, we also discussed how the above-mentioned micro/nanoparticle features impact in vitro and in vivo applications. Through this review, we highlighted the unique opportunities in generating controllable particles via advanced manufacturing techniques and the great potential of using these micro/nanoparticles for therapeutic delivery. PMID:29670013
A three-level support method for smooth switching of the micro-grid operation model
NASA Astrophysics Data System (ADS)
Zong, Yuanyang; Gong, Dongliang; Zhang, Jianzhou; Liu, Bin; Wang, Yun
2018-01-01
Smooth switching of micro-grid between the grid-connected operation mode and off-grid operation mode is one of the key technologies to ensure it runs flexible and efficiently. The basic control strategy and the switching principle of micro-grid are analyzed in this paper. The reasons for the fluctuations of the voltage and the frequency in the switching process are analyzed from views of power balance and control strategy, and the operation mode switching strategy has been improved targeted. From the three aspects of controller’s current inner loop reference signal, voltage outer loop control strategy optimization and micro-grid energy balance management, a three-level security strategy for smooth switching of micro-grid operation mode is proposed. From the three aspects of controller’s current inner loop reference signal tracking, voltage outer loop control strategy optimization and micro-grid energy balance management, a three-level strategy for smooth switching of micro-grid operation mode is proposed. At last, it is proved by simulation that the proposed control strategy can make the switching process smooth and stable, the fluctuation problem of the voltage and frequency has been effectively improved.
Schweitzer, Maria K; Wilting, Fabiola; Sedej, Simon; Dreizehnter, Lisa; Dupper, Nathan J; Tian, Qinghai; Moretti, Alessandra; My, Ilaria; Kwon, Ohyun; Priori, Silvia G; Laugwitz, Karl-Ludwig; Storch, Ursula; Lipp, Peter; Breit, Andreas; Mederos Y Schnitzler, Michael; Gudermann, Thomas; Schredelseker, Johann
2017-12-01
Cardiovascular disease-related deaths frequently arise from arrhythmias, but treatment options are limited due to perilous side effects of commonly used antiarrhythmic drugs. Cardiac rhythmicity strongly depends on cardiomyocyte Ca 2+ handling and prevalent cardiac diseases are causally associated with perturbations in intracellular Ca 2+ handling. Therefore, intracellular Ca 2+ transporters are lead candidate structures for novel and safer antiarrhythmic therapies. Mitochondria and mitochondrial Ca 2+ transport proteins are important regulators of cardiac Ca 2+ handling. Here we evaluated the potential of pharmacological activation of mitochondrial Ca 2+ uptake for the treatment of cardiac arrhythmia. To this aim,we tested substances that enhance mitochondrial Ca 2+ uptake for their ability to suppress arrhythmia in a murine model for ryanodine receptor 2 (RyR2)-mediated catecholaminergic polymorphic ventricular tachycardia (CPVT) in vitro and in vivo and in induced pluripotent stem cell-derived cardiomyocytes from a CPVT patient. In freshly isolated cardiomyocytes of RyR2 R4496C/WT mice efsevin, a synthetic agonist of the voltage-dependent anion channel 2 (VDAC2) in the outer mitochondrial membrane, prevented the formation of diastolic Ca 2+ waves and spontaneous action potentials. The antiarrhythmic effect of efsevin was abolished by blockade of the mitochondrial Ca 2+ uniporter (MCU), but could be reproduced using the natural MCU activator kaempferol. Both mitochondrial Ca 2+ uptake enhancers (MiCUps), efsevin and kaempferol, significantly reduced episodes of stress-induced ventricular tachycardia in RyR2 R4496C/WT mice in vivo and abolished diastolic, arrhythmogenic Ca 2+ events in human iPSC-derived cardiomyocytes.
Ma, Qingping; Chen, Changsong; Zeng, Zhongping; Zou, Zhongwei; Li, Huan; Zhou, Qiongqiong; Chen, Xuan; Sun, Kang; Li, Xinghui
2018-04-25
Self-incompatibility (SI) is a major barrier that obstructs the breeding process in most horticultural plants including tea plants (Camellia sinensis). The aim of this study was to elucidate the molecular mechanism of SI in tea plants through a high throughput transcriptome analysis. In this study, the transcriptomes of self- and cross-pollinated pistils of two tea cultivars 'Fudingdabai' and 'Yulv' were compared to elucidate the SI mechanism of tea plants. In addition, the ion components and pollen tube growth in self- and cross-pollinated pistils were investigated. Our results revealed that both cultivars had similar pollen activities and cross-pollination could promote the pollen tube growth. In tea pistils, the highest ion content was potassium (K + ), followed by calcium (Ca 2+ ), magnesium (Mg 2+ ) and phosphorus (P 5+ ). Ca 2+ content increased after self-pollination but decreased after cross-pollination, while K + showed reverse trend with Ca 2+ . A total of 990 and 3 common differentially expressed genes (DEGs) were identified in un-pollinated vs. pollinated pistils and self- vs. cross-pollinated groups after 48 h, respectively. Function annotation indicated that three genes encoding UDP-glycosyltransferase 74B1 (UGT74B1), Mitochondrial calcium uniporter protein 2 (MCU2) and G-type lectin S-receptor-like serine/threonine-protein kinase (G-type RLK) might play important roles during SI process in tea plants. Ca 2+ and K + are important signal for SI in tea plants, and three genes including UGT74B1, MCU2 and G-type RLK play essential roles during SI signal transduction.
Moerke, Caroline; Mueller, Petra; Nebe, Barbara
2016-06-01
The provided data contains the phagocytic interaction of human MG-63 osteoblasts with micro-particles 6 µm in size as well as geometric micro-pillared topography with micro-pillar sizes 5 µm of length, width, height and spacing respectively related to the research article entitled "Attempted caveolae-mediated phagocytosis of surface-fixed micro-pillars by human osteoblasts" in the Biomaterials journal. [1] Micro-particle treatment was used as positive control triggering phagocytosis by the osteoblasts. Caveolin-1 (Cav-1) as major structural component of caveolae [2] plays an important role in the phagocytic process of micro-particles and -pillars. Data related to the experiments in [1] with siRNA-mediated knockdown are presented here as well as micro-particle control experiments, tubulin analysis on the micro-pillared topography and initial cell interaction with the micro-pillars.
Rivera, José; Carrillo, Mariano; Chacón, Mario; Herrera, Gilberto; Bojorquez, Gilberto
2007-01-01
The development of smart sensors involves the design of reconfigurable systems capable of working with different input sensors. Reconfigurable systems ideally should spend the least possible amount of time in their calibration. An autocalibration algorithm for intelligent sensors should be able to fix major problems such as offset, variation of gain and lack of linearity, as accurately as possible. This paper describes a new autocalibration methodology for nonlinear intelligent sensors based on artificial neural networks, ANN. The methodology involves analysis of several network topologies and training algorithms. The proposed method was compared against the piecewise and polynomial linearization methods. Method comparison was achieved using different number of calibration points, and several nonlinear levels of the input signal. This paper also shows that the proposed method turned out to have a better overall accuracy than the other two methods. Besides, experimentation results and analysis of the complete study, the paper describes the implementation of the ANN in a microcontroller unit, MCU. In order to illustrate the method capability to build autocalibration and reconfigurable systems, a temperature measurement system was designed and tested. The proposed method is an improvement over the classic autocalibration methodologies, because it impacts on the design process of intelligent sensors, autocalibration methodologies and their associated factors, like time and cost.
A wearable, low-power, health-monitoring instrumentation based on a Programmable System-on-Chip.
Massot, Bertrand; Gehin, Claudine; Nocua, Ronald; Dittmar, Andre; McAdams, Eric
2009-01-01
Improvement in quality and efficiency of health and medicine, at home and in hospital, has become of paramount importance. The solution of this problem would require the continuous monitoring of several key patient parameters, including the assessment of autonomic nervous system (ANS) activity using non-invasive sensors, providing information for emotional, sensorial, cognitive and physiological analysis of the patient. Recent advances in embedded systems, microelectronics, sensors and wireless networking enable the design of wearable systems capable of such advanced health monitoring. The subject of this article is an ambulatory system comprising a small wrist device connected to several sensors for the detection of the autonomic nervous system activity. It affords monitoring of skin resistance, skin temperature and heart activity. It is also capable of recording the data on a removable media or sending it to computer via a wireless communication. The wrist device is based on a Programmable System-on-Chip (PSoC) from Cypress: PSoCs are mixed-signal arrays, with dynamic, configurable digital and analogical blocks and an 8-bit Microcontroller unit (MCU) core on a single chip. In this paper we present first of all the hardware and software architecture of the device, and then results obtained from initial experiments.
Alevizos, Ilias; Alexander, Stefanie; Turner, R. James; Illei, Gabor G.
2013-01-01
Objective MicroRNA reflect physiologic and pathologic processes and may be used as biomarkers of concurrent pathophysiologic events in complex settings such as autoimmune diseases. We generated microRNA microarray profiles from the minor salivary glands of control subjects without Sjögren's syndrome (SS) and patients with SS who had low-grade or high-grade inflammation and impaired or normal saliva production, to identify microRNA patterns specific to salivary gland inflammation or dysfunction. Methods MicroRNA expression profiles were generated by Agilent microRNA arrays. We developed a novel method for data normalization by identifying housekeeping microRNA. MicroRNA profiles were compared by unsupervised mathematical methods to test how well they distinguish between control subjects and various subsets of patients with SS. Several bioinformatics methods were used to predict the messenger RNA targets of the differentially expressed microRNA. Results MicroRNA expression patterns accurately distinguished salivary glands from control subjects and patients with SS who had low-degree or high-degree inflammation. Using real-time quantitative polymerase chain reaction, we validated 2 microRNA as markers of inflammation in an independent cohort. Comparing microRNA from patients with preserved or low salivary flow identified a set of differentially expressed microRNA, most of which were up-regulated in the group with decreased salivary gland function, suggesting that the targets of microRNA may have a protective effect on epithelial cells. The predicted biologic targets of microRNA associated with inflammation or salivary gland dysfunction identified both overlapping and distinct biologic pathways and processes. Conclusion Distinct microRNA expression patterns are associated with salivary gland inflammation and dysfunction in patients with SS, and microRNA represent a novel group of potential biomarkers. PMID:21280008
NASA Astrophysics Data System (ADS)
Cahoy, K.; Blackwell, W. J.; Allen, G.; Bury, M.; Efromson, R.; Galbraith, C.; Hancock, T.; Leslie, V.; Osaretin, I.; Retherford, L.; Scarito, M.; Shields, M.; Toher, D.; Wight, K.; Miller, D.; Marinan, A.; Paek, S.; Peters, E.; Schmidt, F. H.; Alvisio, B.; Wise, E.; Masterson, R.; Franzim Miranda, D.; Crail, C.; Kingsbury, R.; Souffrant, A.; Orrego, L.; Eslinger, G.; Nicholas, A.; Pong, C.
2012-12-01
The recently published Midterm Assessment of NASA's Implementation of the Decadal Survey finds that, "The nation's Earth observing system is beginning a rapid decline in capability as long-running missions end and key new missions are delayed, lost, or canceled. The projected loss of observing capability could have significant adverse consequences for science and society." In this presentation, we explore low-cost, mission-flexible, and rapidly deployable spaceborne sensors that can meet stringent performance requirements pervading the NASA Earth Science measurement programs, including especially the recommended NRC Decadal Survey missions. New technologies have enabled a novel approach toward this science observational goal, and in this paper we describe recent technology develop efforts to address the challenges above through the use of CubeSat radiometers. The Micro-sized Microwave Atmospheric Satellite (MicroMAS) is a 3U cubesat (30x10x10 cm, ~4kg) hosting a passive microwave spectrometer operating near the 118.75-GHz oxygen absorption line. The focus of the first MicroMAS mission (hereafter, MicroMAS-1) is to observe convective thunderstorms, tropical cyclones, and hurricanes from a near-equatorial orbit at approximately 500-km altitude. A MicroMAS flight unit is currently being developed in anticipation of a 2014 launch to be provided by NASA. A parabolic reflector is mechanically rotated as the spacecraft orbits the earth, thus directing a cross-track scanned beam with FWHM beamwidth of 2.4-degrees, yielding an approximately 25-km diameter footprint from a nominal altitude of 500 km. Radiometric calibration is carried out using observations of cold space, the earth's limb, and an internal noise diode that is weakly coupled through the RF front-end electronics. A key technology feature is the development of an ultra-compact intermediate frequency processor module for channelization, detection, and A-to-D conversion. The antenna system and RF front-end electronics are highly integrated and miniaturized. A MicroMAS-2 mission is currently being planned using a multi-band spectrometer operating near 118 and 183 GHz in a sun-synchronous orbit of approximately 800-km altitude. A HyMAS-1 (Hyperspectral Microwave Atmospheric Satellite) mission with approximately 50 channels near 118 and 183 GHz is also being planned. In this talk, the mission concept of operations will be discussed, the radiometer payload will be described, and the spacecraft subsystems (avionics, power, communications, attitude determination and control, and mechanical structures) will be summarized. Test data from the recently completed MicroMAS Engineering Development Model (EDM) will also be presented. This work was sponsored by the National Oceanic and Atmospheric Administration under Air Force contract FA8721-05-C-0002. Opinions, interpretations, conclusions, and recommendations are those of the authors and not necessarily endorsed by the United States Government.
Nomura, N; Saito, K; Ikeda, M; Yuasa, S; Pastore, M; Chabert, C; Kono, E; Sakai, A; Tanaka, H; Ikemoto, T; Takubo, T
2015-08-01
We evaluated the basic performance of Microsemi CRP, an unique automated hematology analyzer which can simultaneously measure CBC including 3-part WBC differential (3-Diff) and CRP using whole blood treated with EDTA-2K anticoagulant. We found that it produced generally the acceptable results for all parameters performed (repeatability, reproducibility, linearity, interference effect, carry over, and correlation) using control materials, fresh human whole bloods, and serum samples. CBC data examined using Microsemi CRP showed the good correlation with the previous model, Micros CRP200 (r ≧ 0.9), and also those obtained using the routine analyzer, ADVIA 2120i (r ≧ 0.989). Concerning the 3-Diff, both GRA (%) and LYM (%) showed the excellent correlation coefficient between Microsemi CRP and Micros CRP200 (r ≧ 0.992) as well as ADVIA 2120i (r ≧ 0.957). MON (%) showed good correlation between Microsemi CRP and Micros CRP200 (r = 0.959), but lower correlation between Microsemi CRP and ADVIA 2120 i (r = 0.471). CRP data showed the good correlation with HITACHI7600 (r ≧ 0.997) and Micros CRP200 (r ≧ 0.997). From these findings, we concluded that Microsemi CRP seemed the convenient laboratory analyzer in the setting of point of care testing (POCT) especially at NICU or primary care unit. © 2014 John Wiley & Sons Ltd.
Shaping electromagnetic waves using software-automatically-designed metasurfaces.
Zhang, Qian; Wan, Xiang; Liu, Shuo; Yuan Yin, Jia; Zhang, Lei; Jun Cui, Tie
2017-06-15
We present a fully digital procedure of designing reflective coding metasurfaces to shape reflected electromagnetic waves. The design procedure is completely automatic, controlled by a personal computer. In details, the macro coding units of metasurface are automatically divided into several types (e.g. two types for 1-bit coding, four types for 2-bit coding, etc.), and each type of the macro coding units is formed by discretely random arrangement of micro coding units. By combining an optimization algorithm and commercial electromagnetic software, the digital patterns of the macro coding units are optimized to possess constant phase difference for the reflected waves. The apertures of the designed reflective metasurfaces are formed by arranging the macro coding units with certain coding sequence. To experimentally verify the performance, a coding metasurface is fabricated by automatically designing two digital 1-bit unit cells, which are arranged in array to constitute a periodic coding metasurface to generate the required four-beam radiations with specific directions. Two complicated functional metasurfaces with circularly- and elliptically-shaped radiation beams are realized by automatically designing 4-bit macro coding units, showing excellent performance of the automatic designs by software. The proposed method provides a smart tool to realize various functional devices and systems automatically.
NASA Technical Reports Server (NTRS)
Yang, Ren; Feeback, Daniel L.; Wang, Wan-Jun
2005-01-01
This paper details a novel three-dimensional (3D) hydro-focusing micro cell sorter for micro flow cytometry applications. The unit was microfabricated by means of SU-8 3D lithography. The 3D microstructure for coaxial sheathing was designed, microfabricated, and tested. Three-dimensional hydrofocusing capability was demonstrated with an experiment to sort labeled tanned sheep erythrocytes (red blood cells). This polymer hydro-focusing microstructure is easily microfabricated and integrated with other polymer microfluidic structures. Keywords: SU-8, three-dimensional hydro-focusing, microfluidic, microchannel, cytometer
a New Approach for Complete Mixing by Transverse and Streamwise Flow Motions in Micro-Channels
NASA Astrophysics Data System (ADS)
Wang, Muh-Rong; Dai, Chiau-Yi; Huang, Yang-Sheng
Mixing control is an important issue in micro-fluid chip applications, such as μTAS (Micro-Total Analysis System) or LOC (Lab-on-Chip) because the flow at micro-scale is highly laminar. Several flow control schemes had been developed for complete mixing in the micro-channels in the past decades. However, most of the mixing control schemes are performed by utilizing specific excitation devices, such as electrokinetic, magnetic or pressure drivers. This paper investigates a new control scheme which is composed of a series of flow manipulation by changing the pressure at the two inlets of the micromixer as the external excitation. The fluids from two inlets are introduced to a square mixing chamber, which provides a space where the streamwise and transverse flow motions take place. The results show that the micromixer can be used to produce a large recirculation zone with series of small transverse fringes under external excitations. It is found that this new flow pattern enhances mixing processes at the micro-scale. A complete mixing can be achieved under appropriate flow control with the corresponding design.
Identification of suitable reference genes for hepatic microRNA quantitation.
Lamba, Vishal; Ghodke-Puranik, Yogita; Guan, Weihua; Lamba, Jatinder K
2014-03-07
MicroRNAs (miRNAs) are short (~22 nt) endogenous RNAs that play important roles in regulating expression of a wide variety of genes involved in different cellular processes. Alterations in microRNA expression patterns have been associated with a number of human diseases. Accurate quantitation of microRNA levels is important for their use as biomarkers and in determining their functions. Real time PCR is the gold standard and the most frequently used technique for miRNA quantitation. Real time PCR data analysis includes normalizing the amplification data to suitable endogenous control/s to ensure that microRNA quantitation is not affected by the variability that is potentially introduced at different experimental steps. U6 (RNU6A) and RNU6B are two commonly used endogenous controls in microRNA quantitation. The present study was designed to investigate inter-individual variability and gender differences in hepatic microRNA expression as well as to identify the best endogenous control/s that could be used for normalization of real-time expression data in liver samples. We used Taqman based real time PCR to quantitate hepatic expression levels of 22 microRNAs along with U6 and RNU6B in 50 human livers samples (25 M, 25 F). To identify the best endogenous controls for use in data analysis, we evaluated the amplified candidates for their stability (least variability) in expression using two commonly used software programs: Normfinder and GeNormplus, Both Normfinder and GeNormplus identified U6 to be among the least stable of all the candidates analyzed, and RNU6B was also not among the top genes in stability. mir-152 and mir-23b were identified to be the two most stable candidates by both Normfinder and GeNormplus in our analysis, and were used as endogenous controls for normalization of hepatic miRNA levels. Measurements of microRNA stability indicate that U6 and RNU6B are not suitable for use as endogenous controls for normalizing microRNA relative quantitation data in hepatic tissue, and their use can led to possibly erroneous conclusions.
Note: A resonating reflector-based optical system for motion measurement in micro-cantilever arrays
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sathishkumar, P.; Punyabrahma, P.; Sri Muthu Mrinalini, R.
A robust, compact optical measurement unit for motion measurement in micro-cantilever arrays enables development of portable micro-cantilever sensors. This paper reports on an optical beam deflection-based system to measure the deflection of micro-cantilevers in an array that employs a single laser source, a single detector, and a resonating reflector to scan the measurement laser across the array. A strategy is also proposed to extract the deflection of individual cantilevers from the acquired data. The proposed system and measurement strategy are experimentally evaluated and demonstrated to measure motion of multiple cantilevers in an array.
A Force-Controllable Macro-Micro Manipulator and its Application to Medical Robotics
NASA Technical Reports Server (NTRS)
Marzwell, Neville I.; Uecker, Darrin R.; Wang, Yulun
1993-01-01
This paper describes an 8-degrees-of-freedom macro-micro robot. This robot is capable of performing tasks that require accurate force control, such as polishing, finishing, grinding, deburring, and cleaning. The design of the macro-micro mechanism, the control algorithms, and the hardware/sofware implemtation of the algotithms are described in this paper. Initial experimental results are reported.
NASA Astrophysics Data System (ADS)
Magg, Manfred; Grillenbeck, Anton, , Dr.
2004-08-01
Several samples of thermal control blankets were subjected to transient thermal loads in a thermal vacuum chamber in order to study their ability to excite micro- vibrations on a carrier structure and to cause tiny centre- of-gravity shifts. The reason for this investigation was driven by the GOCE project in order to minimize micro- vibrations on-board of the spacecraft while on-orbit. The objectives of this investigation were to better understand the mechanism which may produce micro- vibrations induced by the thermal control blankets, and to identify thermal control blanket lay-ups with minimum micro-vibration activity.
Selective cyclopalladation of R3P=NCH2Aryl iminophosphoranes. Experimental and computational study.
Bielsa, Raquel; Navarro, Rafael; Urriolabeitia, Esteban P; Lledós, Agustí
2007-11-26
The orientation of the orthopalladation of iminophosphoranes R3P=NCH2Aryl (R=Ph, Aryl=Ph (1a), C6H(4)-2-Br (1b), C6H4-Me-2 (1e), C6H3-(Me)(2)-2,5 (1f); R=p-tolyl, Aryl=Ph (1c); R=m-tolyl, Aryl=Ph (1d); R3P=MePh2P, and Aryl=Ph (1g)) has been studied. 1a reacts with Pd(OAc)2 (OAc=acetate) giving endo-[Pd(micro-Cl){C,N-C6H4(PPh2=NCH2Ph)-2}]2 (3a), while exo-[Pd(micro-Br){C,N-C6H4(CH2N=PPh3)-2}]2 (3b) could only be obtained by the oxidative addition of 1b to Pd2(dba)3. The endo form of the metalated ligand is favored kinetically and thermodynamically, as shown by the conversion of exo-[Pd(micro-OAc){C,N-C6H4(CH2N=PPh3)-2}]2 (2b) into endo-[Pd(micro-OAc){C,N-C6H4(PPh2=NCH2Ph)-2}]2 (2a) in refluxing toluene. The orientation of the reaction is not affected by the introduction of electron-releasing substituents at the Ph rings of the PR3 (1c and 1d) or the benzyl units (1e and 1f), and endo complexes (3c-3f) were obtained in all cases. The palladation of MePh2P=NCH2Ph (1g) can be regioselectively oriented as a function of the solvent. The exo isomer [Pd(micro-Cl){C6H4(CH2N=PPh2Me)-2}]2 (exo-3g) is obtained in refluxing CH2Cl2, while endo-[Pd(micro-Cl){C,N-C6H4(PPh(Me)=NCH2Ph)-2}]2 (endo-3g) can be isolated as a single isomer in refluxing toluene. In this case, the exo metalation is kinetically favored while an endo process occurs under thermodynamic control, as shown through the rearrangement of [Pd(micro-OAc){C6H4(CH2N=PPh2Me)-2}]2 (exo-2g) into [Pd(micro-OAc){C,N-C6H4(P(Ph)Me=NCH2Ph)-2}]2 (endo-2g) in refluxing toluene. The preference for the endo palladation of 1a and the kinetic versus thermodynamic control in 1g has been explained through DFT studies of the reaction mechanism.
NASA Astrophysics Data System (ADS)
Kojima, Hirohisa; Hiraiwa, Kana; Yoshimura, Yasuhiro
2018-02-01
This paper presents the results of line-of-sight (LOS) attitude control using control moment gyros under a micro-gravity environment generated by parabolic flight. The W-Z parameters are used to describe the spacecraft attitude. In order to stabilize the current LOS to the target LOS, backstepping-based feedback control is considered using the W-Z parameters. Numerical simulations and experiments under a micro-gravity environment are carried out, and their results are compared in order to validate the proposed control methods.
A macro-micro robot for precise force applications
NASA Technical Reports Server (NTRS)
Marzwell, Neville I.; Wang, Yulun
1993-01-01
This paper describes an 8 degree-of-freedom macro-micro robot capable of performing tasks which require accurate force control. Applications such as polishing, finishing, grinding, deburring, and cleaning are a few examples of tasks which need this capability. Currently these tasks are either performed manually or with dedicated machinery because of the lack of a flexible and cost effective tool, such as a programmable force-controlled robot. The basic design and control of the macro-micro robot is described in this paper. A modular high-performance multiprocessor control system was designed to provide sufficient compute power for executing advanced control methods. An 8 degree of freedom macro-micro mechanism was constructed to enable accurate tip forces. Control algorithms based on the impedance control method were derived, coded, and load balanced for maximum execution speed on the multiprocessor system.
Study on the Automatic Detection Method and System of Multifunctional Hydrocephalus Shunt
NASA Astrophysics Data System (ADS)
Sun, Xuan; Wang, Guangzhen; Dong, Quancheng; Li, Yuzhong
2017-07-01
Aiming to the difficulty of micro pressure detection and the difficulty of micro flow control in the testing process of hydrocephalus shunt, the principle of the shunt performance detection was analyzed.In this study, the author analyzed the principle of several items of shunt performance detection,and used advanced micro pressure sensor and micro flow peristaltic pump to overcome the micro pressure detection and micro flow control technology.At the same time,This study also puted many common experimental projects integrated, and successfully developed the automatic detection system for a shunt performance detection function, to achieve a test with high precision, high efficiency and automation.
Acoustic trapping in bubble-bounded micro-cavities
NASA Astrophysics Data System (ADS)
O'Mahoney, P.; McDougall, C.; Glynne-Jones, P.; MacDonald, M. P.
2016-12-01
We present a method for controllably producing longitudinal acoustic trapping sites inside microfluidic channels. Air bubbles are injected into a micro-capillary to create bubble-bounded `micro-cavities'. A cavity mode is formed that shows controlled longitudinal acoustic trapping between the two air/water interfaces along with the levitation to the centre of the channel that one would expect from a lower order lateral mode. 7 μm and 10 μm microspheres are trapped at the discrete acoustic trapping sites in these micro-cavities.We show this for several lengths of micro-cavity.
Fast, externally triggered, digital phase controller for an optical lattice
NASA Astrophysics Data System (ADS)
Sadgrove, Mark; Nakagawa, Ken'ichi
2011-11-01
We present a method to control the phase of an optical lattice according to an external trigger signal. The method has a latency of less than 30 μs. Two phase locked digital synthesizers provide the driving signal for two acousto-optic modulators which control the frequency and phase of the counter-propagating beams which form a standing wave (optical lattice). A micro-controller with an external interrupt function is connected to the desired external signal, and updates the phase register of one of the synthesizers when the external signal changes. The standing wave (period λ/2 = 390 nm) can be moved by units of 49 nm with a mean jitter of 28 nm. The phase change is well known due to the digital nature of the synthesizer, and does not need calibration. The uses of the scheme include coherent control of atomic matter-wave dynamics.
Design and Control of Flapping Wing Micro Air Vehicles
2011-09-01
unsteady, low Re aerodynamics, micro-fabrication, and fluid - structure interaction. However, research into flapping wing control of such MAVs...and flown in confined spaces such as urban canyons, caves and indoors. MAVs will provide an organic ISR capability to small combat teams in the...Designing for highly coupled fluid -structure interactions Micro-fabrication Stability characterization and control Of these challenges, the most
NASA Astrophysics Data System (ADS)
Pate, S. F.; Wester, T.; Bugel, L.; Conrad, J.; Henderson, E.; Jones, B. J. P.; McLean, A. I. L.; Moon, J. S.; Toups, M.; Wongjirad, T.
2018-02-01
We present a model for the Global Quantum Efficiency (GQE) of the MicroBooNE optical units. An optical unit consists of a flat, circular acrylic plate, coated with tetraphenyl butadiene (TPB), positioned near the photocathode of a 20.2-cm diameter photomultiplier tube. The plate converts the ultra-violet scintillation photons from liquid argon into visible-spectrum photons to which the cryogenic phototubes are sensitive. The GQE is the convolution of the efficiency of the plates that convert the 128 nm scintillation light from liquid argon to visible light, the efficiency of the shifted light to reach the photocathode, and the efficiency of the cryogenic photomultiplier tube. We develop a GEANT4-based model of the optical unit, based on first principles, and obtain the range of probable values for the expected number of detected photoelectrons (NPE) given the known systematic errors on the simulation parameters. We compare results from four measurements of the NPE determined using alpha-particle sources placed at two distances from a TPB-coated plate in a liquid argon cryostat test stand. We also directly measured the radial dependence of the quantum efficiency, and find that this has the same shape as predicted by our model. Our model results in a GQE of 0.0055±0.0009 for the MicroBooNE optical units. While the information shown here is MicroBooNE specific, the approach to the model and the collection of simulation parameters will be widely applicable to many liquid-argon-based light collection systems.
NASA Astrophysics Data System (ADS)
Ng, H. B.; Shearwood, C.
2007-12-01
The successful development of micro-needles can help transport drugs and vaccines both effectively and painlessly across the skin. However, not all micro-needles are strong enough to withstand the insertion forces and viscoelasticity of the skin. The work here focuses on the micro-fabrication of high aspect ratio needles with careful control of needle-profile using dry etching technologies. Silicon micro-needles, 150μm in length with base-diameters ranging from 90 to 240μm have been investigated in this study. A novel, multiple-sacrificial approach has been demonstrated as suited to the fabrication of long micro-needle bodies with positive profiles. The parameters that control the isotropic etching are adjusted to control the ratio of the needle-base diameter to needle length. By careful control of geometry, the needle profile can be engineered to give a suitable tip size for penetration, as well as a broad needle base to facilitate the creation of either single or multiple-through holes. This approach allows the mechanical properties of the otherwise brittle needles to be optimized. Finite element analysis indicates that the micro-needles will fracture prematurely due to buckling, with forces ranging from 10 to 30mN.
Unit cell-based computer-aided manufacturing system for tissue engineering.
Kang, Hyun-Wook; Park, Jeong Hun; Kang, Tae-Yun; Seol, Young-Joon; Cho, Dong-Woo
2012-03-01
Scaffolds play an important role in the regeneration of artificial tissues or organs. A scaffold is a porous structure with a micro-scale inner architecture in the range of several to several hundreds of micrometers. Therefore, computer-aided construction of scaffolds should provide sophisticated functionality for porous structure design and a tool path generation strategy that can achieve micro-scale architecture. In this study, a new unit cell-based computer-aided manufacturing (CAM) system was developed for the automated design and fabrication of a porous structure with micro-scale inner architecture that can be applied to composite tissue regeneration. The CAM system was developed by first defining a data structure for the computing process of a unit cell representing a single pore structure. Next, an algorithm and software were developed and applied to construct porous structures with a single or multiple pore design using solid freeform fabrication technology and a 3D tooth/spine computer-aided design model. We showed that this system is quite feasible for the design and fabrication of a scaffold for tissue engineering.
The Optimization dispatching of Micro Grid Considering Load Control
NASA Astrophysics Data System (ADS)
Zhang, Pengfei; Xie, Jiqiang; Yang, Xiu; He, Hongli
2018-01-01
This paper proposes an optimization control of micro-grid system economy operation model. It coordinates the new energy and storage operation with diesel generator output, so as to achieve the economic operation purpose of micro-grid. In this paper, the micro-grid network economic operation model is transformed into mixed integer programming problem, which is solved by the mature commercial software, and the new model is proved to be economical, and the load control strategy can reduce the charge and discharge times of energy storage devices, and extend the service life of the energy storage device to a certain extent.
2012-01-01
Background Analysis is lacking on the management of vector control systems in disease-endemic countries with respect to the efficiency and sustainability of operations. Methods Three locations were selected, at the scale of province, municipality and barangay (i.e. village). Data on disease incidence, programme activities, and programme management were collected on-site through meetings and focus group discussions. Results Adaptation of disease control strategies to the epidemiological situation per barangay, through micro-stratification, brings gains in efficiency, but should be accompanied by further capacity building on local situational analysis for better selection and targeting of vector control interventions within the barangay. An integrated approach to vector control, aiming to improve the rational use of resources, was evident with a multi-disease strategy for detection and response, and by the use of combinations of vector control methods. Collaboration within the health sector was apparent from the involvement of barangay health workers, re-orientation of job descriptions and the creation of a disease surveillance unit. The engagement of barangay leaders and use of existing community structures helped mobilize local resources and voluntary services for vector control. In one location, local authorities and the community were involved in the planning, implementation and evaluation of malaria control, which triggered local programme ownership. Conclusions Strategies that contributed to an improved efficiency and sustainability of vector control operations were: micro-stratification, integration of vector control within the health sector, a multi-disease approach, involvement of local authorities, and empowerment of communities. Capacity building on situational analysis and vector surveillance should be addressed through national policy and guidelines. PMID:22873707
Interaction of microRNA-21/145 and Smad3 domain-specific phosphorylation in hepatocellular carcinoma
Wang, Ji Yu; Fang, Meng; Boye, Alex; Wu, Chao; Wu, Jia Jun; Ma, Ying; Hou, Shu; Kan, Yue; Yang, Yan
2017-01-01
MicroRNAs 21 and 145 exhibit inverse expression in Hepatocellular carcinoma (HCC), but how they relate to Smad3 C-terminal and Link region phosphorylation (pSmad3C and pSmad3L) downstream of TGF-β/MAPK signaling, remains inconclusive. Our results suggest microRNA-145 targets Smad3 in HepG2 cells. Decreased tumor volume and increased apoptosis were produced in both microRNA-21 antagomir and microRNA-145 agomir groups compared to controls. Inhibition of TβRI and MAPK (ERK, JNK, and p38) activation respectively produced decreased microRNA-21 but increased microRNA-145 expression. Correspondingly, the expression level of pSmad3C obviously increased while pSmad3L decreased in microRNA-145 agomir-group and the expression of pSmad3C/3L were not markedly changed but pERK, pJNK, pp38 decreased in microRNA-21 antagomir-group compared to controls. On the other hand, microRNA-145 and 21 increased respectively in xenografts of HepG2 cells transfected with Smad3 EPSM and 3S-A plasmid, and this correlated with the overexpression of pSmad3C and pSmad3L respectively compared to control. To conclude, microRNA-21 promotes tumor progression in a MAPK-dependent manner while microRNA-145 suppresses it via domain-specific phosphorylation of Smad3 in HCC. Meanwhile, increased pSmad3C/3L lead to the up-regulation of microRNA-145/21 respectively. The interaction between pSmad3C/3L and microRNA-145/21 regulates HCC progression and the switch of pSmad3C/3L may serve as an important target for HCC therapy. PMID:29156696
A low power flash-FPGA based brain implant micro-system of PID control.
Lijuan Xia; Fattah, Nabeel; Soltan, Ahmed; Jackson, Andrew; Chester, Graeme; Degenaar, Patrick
2017-07-01
In this paper, we demonstrate that a low power flash FPGA based micro-system can provide a low power programmable interface for closed-loop brain implant inter- faces. The proposed micro-system receives recording local field potential (LFP) signals from an implanted probe, performs closed-loop control using a first order control system, then converts the signal into an optogenetic control stimulus pattern. Stimulus can be implemented through optoelectronic probes. The long term target is for both fundamental neuroscience applications and for clinical use in treating epilepsy. Utilizing our device, closed-loop processing consumes only 14nJ of power per PID cycle compared to 1.52μJ per cycle for a micro-controller implementation. Compared to an application specific digital integrated circuit, flash FPGA's are inherently programmable.
Sedikides, Constantine; Gebauer, Jochen E
2010-02-01
In a meta-analysis, the authors test the theoretical formulation that religiosity is a means for self-enhancement. The authors operationalized self-enhancement as socially desirable responding (SDR) and focused on three facets of religiosity: intrinsic, extrinsic, and religion-as-quest. Importantly, they assessed two moderators of the relation between SDR and religiosity. Macro-level culture reflected countries that varied in degree of religiosity (from high to low: United States, Canada, United Kingdom). Micro-level culture reflected U.S. universities high (Christian) versus low (secular) on religiosity. The results were generally consistent with the theoretical formulation. Both macro-level and micro-level culture moderated the relation between SDR and religiosity: This relation was more positive in samples that placed higher value on religiosity (United States > Canada > United Kingdom; Christian universities > secular universities). The evidence suggests that religiosity is partly in the service of self-enhancement.
Micro guidance and control synthesis: New components, architectures, and capabilities
NASA Technical Reports Server (NTRS)
Mettler, Edward; Hadaegh, Fred Y.
1993-01-01
New GN&C (guidance, navigation and control) system capabilities are shown to arise from component innovations that involve the synergistic use of microminiature sensors and actuators, microelectronics, and fiber optics. Micro-GN&C system and component concepts are defined that include micro-actuated adaptive optics, micromachined inertial sensors, fiber-optic data nets and light-power transmission, and VLSI microcomputers. The thesis is advanced that these micro-miniaturization products are capable of having a revolutionary impact on space missions and systems, and that GN&C is the pathfinder micro-technology application that can bring that about.
M.D. Bryant; B.E. Wright; B.J. Davies
1992-01-01
A hierarchical classification system separating stream habitat into habitat units defined by stream morphology and hydrology was used in a pre-enhancement stream survey. The system separates habitat units into macrounits, mesounits, and micro- units and includes a separate evaluation of instream cover that also uses the hierarchical scheme. This paper presents an...
Application of Micro-ramp Flow Control Devices to an Oblique Shock Interaction
NASA Technical Reports Server (NTRS)
Hirt, Stefanie; Anderson, Bernhard
2007-01-01
Tests are planned in the 15cm x 15cm supersonic wind tunnel at NASA Glenn to demonstrate the applicability of micro-ramp flow control to the management of shock wave boundary layer interactions. These tests will be used as a database for computational fluid dynamics (CFD) validation and Design of Experiments (DoE) design information. Micro-ramps show potential for mechanically simple and fail-safe boundary layer control.
Ayers, L; Ferry, B; Craig, S; Nicoll, D; Stradling, J R; Kohler, M
2009-03-01
Moderate-severe obstructive sleep apnoea (OSA) has been associated with several pro-atherogenic mechanisms and increased cardiovascular risk, but it is not known if minimally symptomatic OSA has similar effects. Circulating cell-derived microparticles have been shown to have pro-inflammatory, pro-coagulant and endothelial function-impairing effects, as well as to predict subclinical atherosclerosis and cardiovascular risk. In 57 patients with minimally symptomatic OSA, and 15 closely matched control subjects without OSA, AnnexinV-positive, platelet-, leukocyte- and endothelial cell-derived microparticles were measured by flow cytometry. In patients with OSA, median (interquartile range) levels of AnnexinV-positive microparticles were significantly elevated compared with control subjects: 2,586 (1,566-3,964) microL(-1) versus 1,206 (474-2,501) microL(-1), respectively. Levels of platelet-derived and leukocyte-derived microparticles were also significantly higher in patients with OSA (2,267 (1,102-3,592) microL(-1) and 20 (14-31) microL(-1), respectively) compared with control subjects (925 (328-2,068) microL(-1) and 15 (5-23) microL(-1), respectively). Endothelial cell-derived microparticle levels were similar in patients with OSA compared with control subjects (13 (8-25) microL(-1) versus 11 (6-17) microL(-1)). In patients with minimally symptomatic obstructive sleep apnoea, levels of AnnexinV-positive, platelet- and leukocyte-derived microparticles are elevated when compared with closely matched control subjects without obstructive sleep apnoea. These findings suggest that these patients may be at increased cardiovascular risk, despite being minimally symptomatic.
A Monolithic Electrochemical Micro Seismic Sensor Capable of Monitoring Three-Dimensional Vibrations
Chen, Lianhong; Sun, Zhenyuan; Li, Guanglei; Chen, Deyong; Wang, Junbo
2018-01-01
A monolithic electrochemical micro seismic sensor capable of monitoring three-axial vibrations was proposed in this paper. The proposed micro sensor mainly consisted of four sensing units interconnected within flow channels and by interpreting the voltage outputs of the sensing units, vibrations with arbitrary directions can be quantified. The proposed seismic sensors are fabricated based on MEMS technologies and characterized, which produced sensitivities along x, y, and z axes as 2473.2 ± 184.5 V/(m/s), 2261.7 ± 119.6 V/(m/s), and 3480.7 ± 417.2 V/(m/s) at 30 Hz. In addition, the vibrations in x-y, x-z, and y-z planes were applied to the developed seismic sensors, leading to comparable monitoring results after decoupling calculations with the input velocities. Furthermore, the results have shown its feasibilities for seismic data recording. PMID:29614720
Collision count in rugby union: A comparison of micro-technology and video analysis methods.
Reardon, Cillian; Tobin, Daniel P; Tierney, Peter; Delahunt, Eamonn
2017-10-01
The aim of our study was to determine if there is a role for manipulation of g force thresholds acquired via micro-technology for accurately detecting collisions in rugby union. In total, 36 players were recruited from an elite Guinness Pro12 rugby union team. Player movement profiles and collisions were acquired via individual global positioning system (GPS) micro-technology units. Players were assigned to a sub-category of positions in order to determine positional collision demands. The coding of collisions by micro-technology at g force thresholds between 2 and 5.5 g (0.5 g increments) was compared with collision coding by an expert video analyst using Bland-Altman assessments. The most appropriate g force threshold (smallest mean difference compared with video analyst coding) was lower for all forwards positions (2.5 g) than for all backs positions (3.5 g). The Bland-Altman 95% limits of agreement indicated that there may be a substantial over- or underestimation of collisions coded via GPS micro-technology when using expert video analyst coding as the reference comparator. The manipulation of the g force thresholds applied to data acquired by GPS micro-technology units based on incremental thresholds of 0.5 g does not provide a reliable tool for the accurate coding of collisions in rugby union. Future research should aim to investigate smaller g force threshold increments and determine the events that cause coding of false positives.
Profile of urinary tract infections in paediatric patients
Gupta, Palak; Mandal, Jharna; Krishnamurthy, Sriram; Barathi, Deepak; Pandit, Nandini
2015-01-01
Background & objectives: This cross-sectional study was conducted at a tertiary care centre in Puducherry, south India, with the aim of finding the profile of the paediatric urinary tract infection (UTI), bacterial pathogens involved, and also to observe vesicoureteric reflux (VUR) and renal scarring in these patients. Methods: A total of 524 paediatric patients ≤13 yr, suspected to have UTI, were included in the study. Urine samples were collected, processed for uropathogen isolation and antibiotic susceptibility test was performed as per the Clinical and Laboratory Standards Institute (CLSI) guidelines. Thirty two culture proven children with UTI underwent micturating cysto-urethrography (MCU) and dimercaptosuccinic acid (DMSA) scanning was done for 69 children. Results: of the 524 children, 186 (35.4%) had culture proven UTI with 105 (56.4%) being infants, 50 (27.4%) between 1-5 yr, 30 (16.12%) between 5-13 yr and 129 (69.35%) males. Posterior urethral valve (PUV) was noted in three, hydronephrosis in one, VUR in 18 and renal scarring in 33. VUR as well as renal scarring were more in males >1 yr of age. A significant association (P=0.0054) was noted with a combined sensitivity and specificity of these investigations being 83 and 90 per cent, respectively of the MCU and DMSA scans for detecting VUR. Escherichia coli was the most common pathogen isolated, sensitive to nitrofurantoin, followed by cefoperazone-sulbactam, aminoglycosides and meropenem. Interpretation & conclusions: Our results indicate that UTI varies with age and gender and extensive evaluation is required in boys under one year of age with UTI. This study also highlights the better efficacy of aminoglycosides, cefoperazone-sulbactam and nitrofurantoin in vitro compared with meropenem in Gram–negative uropathogens. PMID:26112850
TRPM2 Channels Protect against Cardiac Ischemia-Reperfusion Injury
Miller, Barbara A.; Hoffman, Nicholas E.; Merali, Salim; Zhang, Xue-Qian; Wang, JuFang; Rajan, Sudarsan; Shanmughapriya, Santhanam; Gao, Erhe; Barrero, Carlos A.; Mallilankaraman, Karthik; Song, Jianliang; Gu, Tongda; Hirschler-Laszkiewicz, Iwona; Koch, Walter J.; Feldman, Arthur M.; Madesh, Muniswamy; Cheung, Joseph Y.
2014-01-01
Cardiac TRPM2 channels were activated by intracellular adenosine diphosphate-ribose and blocked by flufenamic acid. In adult cardiac myocytes the ratio of GCa to GNa of TRPM2 channels was 0.56 ± 0.02. To explore the cellular mechanisms by which TRPM2 channels protect against cardiac ischemia/reperfusion (I/R) injury, we analyzed proteomes from WT and TRPM2 KO hearts subjected to I/R. The canonical pathways that exhibited the largest difference between WT-I/R and KO-I/R hearts were mitochondrial dysfunction and the tricarboxylic acid cycle. Complexes I, III, and IV were down-regulated, whereas complexes II and V were up-regulated in KO-I/R compared with WT-I/R hearts. Western blots confirmed reduced expression of the Complex I subunit and other mitochondria-associated proteins in KO-I/R hearts. Bioenergetic analyses revealed that KO myocytes had a lower mitochondrial membrane potential, mitochondrial Ca2+ uptake, ATP levels, and O2 consumption but higher mitochondrial superoxide levels. Additionally, mitochondrial Ca2+ uniporter (MCU) currents were lower in KO myocytes, indicating reduced mitochondrial Ca2+ uptake was likely due to both lower ψm and MCU activity. Similar to isolated myocytes, O2 consumption and ATP levels were also reduced in KO hearts. Under a simulated I/R model, aberrant mitochondrial bioenergetics was exacerbated in KO myocytes. Reactive oxygen species levels were also significantly higher in KO-I/R compared with WT-I/R heart slices, consistent with mitochondrial dysfunction in KO-I/R hearts. We conclude that TRPM2 channels protect the heart from I/R injury by ameliorating mitochondrial dysfunction and reducing reactive oxygen species levels. PMID:24492610
Muthusamy, Annamalai; Jayabalan, Narayanasamy
2013-01-01
The present work describes the influence of gamma irradiation (GR), ethyl methane sulphonate (EMS) and sodium azide (SA) treatment on yield and protein content of selected mutant lines of cotton. Seeds of MCU 5 and MCU 11 were exposed to gamma rays (GR), ethyl methane sulphonate (EMS) and sodium azide (SA). Lower dose of gamma irradiation (100-500 Gy), 10-50 mM EMS and SA at lower concentration effectively influences in improving the yield and protein content. Significant increase in yield (258.9 g plant(-1)) and protein content (18.63 mg g(-1) d. wt.) as compared to parental lines was noted in M2 generations. During the subsequent field trials, number of mutant lines varied morphologically in terms of yield as well as biochemical characters such as protein. The selected mutant lines were bred true to their characters in M3 and M4 generations. The significant increase in protein content and profiles of the mutant lines with range of 10.21-18.63 mg g(-1). The SDS-PAGE analysis of mutant lines revealed 9 distinct bands of different intensities with range of 26-81 kDa. The difference in intensity of bands was more (41, 50 and 58 kDa) in the mutant lines obtained from in vitro mutation than in vivo mutation. Significance of such stimulation in protein content correlated with yielding ability of the mutant lines of cotton in terms of seed weight per plant. The results confirm that in cotton it is possible to enhance the both yield and biochemical characters by in vivo and in vitro mutagenic treatments.
Unit: Micro-Organisms and Man, Inspection Pack, National Trial Print.
ERIC Educational Resources Information Center
Australian Science Education Project, Toorak, Victoria.
This unit, intended for students in grades eight or nine, is a revised version of ED 053 990. The teacher's guide lists the aims of the unit, behavioral objectives, suitable references and audio-visual aids, required apparatus and materials, and provides teaching notes for each activity, including comments concerning microbiological techniques.…
Jermendy, György
2018-04-01
The effect of antihyperglycaemic (antidiabetic) treatment on the late diabetic complications is one of the most important research areas in clinical diabetology. The relationship between glycaemic control and late micro- and macrovascular complications was highlighted by the results of the DCCT (Diabetes Control and Complications Trial) with type 1 and by the UKPDS (United Kingdom Prospective Diabetes Study) with type 2 diabetic patients. In these studies, observational follow-up investigations were also performed after the close-out of the randomized phase of the trial. In addition to these landmark studies, other randomized, controlled efficacy trials were also performed with observational follow-up investigations resulting in the development of the concept of metabolic memory or metabolic legacy. In this article, the main results of the studies are summarized. Orv Hetil. 2018; 159(15): 575-582.
NASA Technical Reports Server (NTRS)
Hsu, Oscar; Maghami, Peiman; O’Donnell, James R., Jr.; Ziemer, John; Romero-Wolf, Andrew
2017-01-01
The Space Technology-7 Disturbance Reduction System (DRS) launched aboard the European Space Agency's LISA Pathfinder spacecraft on December 3, 2015, after more than a decade in development. DRS consists of three primary components: an Integrated Avionics Unit (IAU), Colloidal MicroNewton Thrusters, and Dynamic Control System (DCS) algorithms implemented on the IAU. During the portions of the mission in which the DRS was under control, the DCS was responsible for controlling the spacecraft and the free-floating test masses that were part of the LISA Test Package. The commissioning period was originally divided into two periods: before propulsion separation and after propulsion separation. A recommissioning period was added after an anomaly occurred in the thruster system. The paper will describe the activities used to commission DRS, present results from the commissioning of the DCS and the recommissioning activities per-formed after the thruster anomaly.
NASA Technical Reports Server (NTRS)
Hsu, Oscar; Maghami, Peiman; O’Donnell, James R., Jr.; Ziemer, John; Romero-Wolf, Andrew
2017-01-01
The Space Technology-7 Disturbance Reduction System (DRS) launched aboard the European Space Agencys LISA Pathfinder spacecraft on December 3, 2015, after more than a decade in development. DRS consists of three prima-ry components: an Integrated Avionics Unit (IAU), Colloidal MicroNewton Thrusters, and Dynamic Control System (DCS) algorithms implemented on the IAU. During the portions of the mission in which the DRS was under control, the DCS was responsible for controlling the spacecraft and the free-floating test masses that were part of the LISA Test Package. The commissioning period was originally divided into two periods: before propulsion separation and after pro-pulsion separation. A recommissioning period was added after an anomaly oc-curred in the thruster system. The paper will describe the activities used to com-mission DRS, present results from the commissioning of the DCS and the re-commissioning activities performed after the thruster anomaly.
Microelectromechanical Systems
NASA Technical Reports Server (NTRS)
Gabriel, Kaigham J.
1995-01-01
Micro-electromechanical systems (MEMS) is an enabling technology that merges computation and communication with sensing and actuation to change the way people and machines interact with the physical world. MEMS is a manufacturing technology that will impact widespread applications including: miniature inertial measurement measurement units for competent munitions and personal navigation; distributed unattended sensors; mass data storage devices; miniature analytical instruments; embedded pressure sensors; non-invasive biomedical sensors; fiber-optics components and networks; distributed aerodynamic control; and on-demand structural strength. The long term goal of ARPA's MEMS program is to merge information processing with sensing and actuation to realize new systems and strategies for both perceiving and controlling systems, processes, and the environment. The MEMS program has three major thrusts: advanced devices and processes, system design, and infrastructure.
Development of a Micro-UAV Hyperspectral Imaging Platform for Assessing Hydrogeological Hazards
NASA Astrophysics Data System (ADS)
Chen, Z.; Alabsi, M.
2015-12-01
The exacerbating global weather changes have cast significant impacts upon the proportion of water supplied to agriculture. Therefore, one of the 21stCentury Grant Challenges faced by global population is securing water for food. However, the soil-water behavior in an agricultural environment is complex; among others, one of the key properties we recognize is water repellence or hydrophobicity, which affects many hydrogeological and hazardous conditions such as excessive water infiltration, runoff, and soil erosion. Under a US-Israel research program funded by USDA and BARD at Israel, we have proposed the development of a novel micro-unmanned aerial vehicle (micro-UAV or drone) based hyperspectral imaging platform for identifying and assessing soil repellence at low altitudes with enhanced flexibility, much reduced cost, and ultimately easy use. This aerial imaging system consists of a generic micro-UAV, hyperspectral sensor aided by GPS/IMU, on-board computing units, and a ground station. The target benefits of this system include: (1) programmable waypoint navigation and robotic control for multi-view imaging; (2) ability of two- or three-dimensional scene reconstruction for complex terrains; and (3) fusion with other sensors to realize real-time diagnosis (e.g., humidity and solar irradiation that may affect soil-water sensing). In this talk we present our methodology and processes in integration of hyperspectral imaging, on-board sensing and computing, hyperspectral data modeling, and preliminary field demonstration and verification of the developed prototype.
Characterization of printable cellular micro-fluidic channels for tissue engineering.
Zhang, Yahui; Yu, Yin; Chen, Howard; Ozbolat, Ibrahim T
2013-06-01
Tissue engineering has been a promising field of research, offering hope of bridging the gap between organ shortage and transplantation needs. However, building three-dimensional (3D) vascularized organs remains the main technological barrier to be overcome. One of the major challenges is the inclusion of a vascular network to support cell viability in terms of nutrients and oxygen perfusion. This paper introduces a new approach to the fabrication of vessel-like microfluidic channels that has the potential to be used in thick tissue or organ fabrication in the future. In this research, we investigate the manufacturability of printable micro-fluidic channels, where micro-fluidic channels support mechanical integrity as well as enable fluid transport in 3D. A pressure-assisted solid freeform fabrication platform is developed with a coaxial needle dispenser unit to print hollow hydrogel filaments. The dispensing rheology is studied, and effects of material properties on structural formation of hollow filaments are analyzed. Sample structures are printed through the developed computer-controlled system. In addition, cell viability and gene expression studies are presented in this paper. Cell viability shows that cartilage progenitor cells (CPCs) maintained their viability right after bioprinting and during prolonged in vitro culture. Real-time PCR analysis yielded a relatively higher expression of cartilage-specific genes in alginate hollow filament encapsulating CPCs, compared with monolayer cultured CPCs, which revealed that printable semi-permeable micro-fluidic channels provided an ideal environment for cell growth and function.
Characterization of Printable Cellular Micro-fluidic Channels for Tissue Engineering
Zhang, Yahui; Yu, Yin; Chen, Howard; Ozbolat, Ibrahim T.
2014-01-01
Tissue engineering has been a promising field of research, offering hope of bridging the gap between organ shortage and transplantation needs. However, building three-dimensional (3D) vascularized organs remains the main technological barrier to be overcome. One of the major challenges is the inclusion of a vascular network to support cell viability in terms of nutrients and oxygen perfusion. This paper introduces a new approach to fabrication of vessel-like microfluidic channels that has the potential to be used in thick tissue or organ fabrication in the future. In this research, we investigate the manufacturability of printable micro-fluidic channels, where micro-fluidic channels support mechanical integrity as well as enable fluid transport in 3D. A pressure-assisted solid freeform fabrication platform is developed with a coaxial needle dispenser unit to print hollow hydrogel filaments. The dispensing rheology is studied, and effects of material properties on structural formation of hollow filaments are analyzed. Sample structures are printed through the developed computer-controlled system. In addition, cell viability and gene expression studies are presented in this paper. Cell viability shows that cartilage progenitor cells (CPCs) maintained their viability right after bioprinting and during prolonged in vitro culture. Real-time PCR analysis yielded relatively higher expression of cartilage-specific genes in alginate hollow filament encapsulating CPCs, compared with monolayer cultured CPCs, which revealed that printable semi-permeable micro-fluidic channels provided an ideal environment for cell growth and function. PMID:23458889
Magalhães, Catarina M; Joye, Samantha B; Moreira, Rosa M; Wiebe, William J; Bordalo, Adriano A
2005-05-01
The regulatory effects of salinity and inorganic nitrogen compounds on nitrification and denitrification were studied in intertidal sandy sediments and rocky biofilms in the Douro River estuary, Portugal, over a 12-month period. Nitrification and denitrification rates were measured in slurries of field samples and enrichment experiments using the difluoromethane and the acetylene inhibition techniques, respectively. Salinity did not regulate denitrification in either environment, suggesting that halotolerant bacteria dominated the denitrifier communities. However, nitrification rates were stimulated when salinity increased from 0 to 15 practical salinity units. NO3- addition experiments revealed that NO3- availability stimulates denitrification rates in sandy sediments, but not in rocky biofilms; however, in rocky biofilms a positive and linear relationship was observed between denitrification rates and water column NO3- concentrations (r=0.92) during the monthly surveys. The N2O:N2 ratios increased rapidly when NO3- increased from 63 to 363 microM; however, results from monthly surveys showed that environmental parameters other than NO3- availability may be important in controlling the variation in N2O production via denitrification. Ammonium additions to sandy sediments stimulated nitrification rates by 35% for the 20 microM NH4+ addition, but NH4+ appeared to inhibit nitrification at high concentration addition (200 microM NH4+). In contrast, rocky biofilm nitrification was stimulated by 65% when 200 microM NH4+ was added.
Biologically Inspired Micro-Flight Research
NASA Technical Reports Server (NTRS)
Raney, David L.; Waszak, Martin R.
2003-01-01
Natural fliers demonstrate a diverse array of flight capabilities, many of which are poorly understood. NASA has established a research project to explore and exploit flight technologies inspired by biological systems. One part of this project focuses on dynamic modeling and control of micro aerial vehicles that incorporate flexible wing structures inspired by natural fliers such as insects, hummingbirds and bats. With a vast number of potential civil and military applications, micro aerial vehicles represent an emerging sector of the aerospace market. This paper describes an ongoing research activity in which mechanization and control concepts for biologically inspired micro aerial vehicles are being explored. Research activities focusing on a flexible fixed- wing micro aerial vehicle design and a flapping-based micro aerial vehicle concept are presented.
Pate, S. F.; Wester, T.; Bugel, L.; ...
2018-02-28
We present a model for the Global Quantum Efficiency (GQE) of the MicroBooNE optical units. An optical unit consists of a flat, circular acrylic plate, coated with tetraphenyl butadiene (TPB), positioned near the photocathode of a 20.2-cm diameter photomultiplier tube. The plate converts the ultra-violet scintillation photons from liquid argon into visible-spectrum photons to which the cryogenic phototubes are sensitive. The GQE is the convolution of the efficiency of the plates that convert the 128 nm scintillation light from liquid argon to visible light, the efficiency of the shifted light to reach the photocathode, and the efficiency of the cryogenic photomultiplier tube. We develop a GEANT4-based model of the optical unit, based on first principles, and obtain the range of probable values for the expected number of detected photoelectrons (more » $$N_{\\rm PE}$$) given the known systematic errors on the simulation parameters. We compare results from four measurements of the $$N_{\\rm PE}$$ determined using alpha-particle sources placed at two distances from a TPB-coated plate in a liquid argon cryostat test stand. We also directly measured the radial dependence of the quantum efficiency, and find that this has the same shape as predicted by our model. Our model results in a GQE of $$0.0055\\pm0.0009$$ for the MicroBooNE optical units. While the information shown here is MicroBooNE specific, the approach to the model and the collection of simulation parameters will be widely applicable to many liquid-argon-based light collection systems.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pate, S. F.; Wester, T.; Bugel, L.
We present a model for the Global Quantum Efficiency (GQE) of the MicroBooNE optical units. An optical unit consists of a flat, circular acrylic plate, coated with tetraphenyl butadiene (TPB), positioned near the photocathode of a 20.2-cm diameter photomultiplier tube. The plate converts the ultra-violet scintillation photons from liquid argon into visible-spectrum photons to which the cryogenic phototubes are sensitive. The GQE is the convolution of the efficiency of the plates that convert the 128 nm scintillation light from liquid argon to visible light, the efficiency of the shifted light to reach the photocathode, and the efficiency of the cryogenic photomultiplier tube. We develop a GEANT4-based model of the optical unit, based on first principles, and obtain the range of probable values for the expected number of detected photoelectrons (more » $$N_{\\rm PE}$$) given the known systematic errors on the simulation parameters. We compare results from four measurements of the $$N_{\\rm PE}$$ determined using alpha-particle sources placed at two distances from a TPB-coated plate in a liquid argon cryostat test stand. We also directly measured the radial dependence of the quantum efficiency, and find that this has the same shape as predicted by our model. Our model results in a GQE of $$0.0055\\pm0.0009$$ for the MicroBooNE optical units. While the information shown here is MicroBooNE specific, the approach to the model and the collection of simulation parameters will be widely applicable to many liquid-argon-based light collection systems.« less
Spatial relationships between alcohol-related road crashes and retail alcohol availability.
Morrison, Christopher; Ponicki, William R; Gruenewald, Paul J; Wiebe, Douglas J; Smith, Karen
2016-05-01
This study examines spatial relationships between alcohol outlet density and the incidence of alcohol-related crashes. The few prior studies conducted in this area used relatively large spatial units; here we use highly resolved units from Melbourne, Australia (Statistical Area level 1 [SA1] units: mean land area=0.5 km(2); SD=2.2 km(2)), in order to assess different micro-scale spatial relationships for on- and off-premise outlets. Bayesian conditional autoregressive Poisson models were used to assess cross-sectional relationships of three-year counts of alcohol-related crashes (2010-2012) attended by Ambulance Victoria paramedics to densities of bars, restaurants, and off-premise outlets controlling for other land use, demographic and roadway characteristics. Alcohol-related crashes were not related to bar density within local SA1 units, but were positively related to bar density in adjacent SA1 units. Alcohol-related crashes were negatively related to off-premise outlet density in local SA1 units. Examined in one metropolitan area using small spatial units, bar density is related to greater crash risk in surrounding areas. Observed negative relationships for off-premise outlets may be because the origins and destinations of alcohol-affected journeys are in distal locations relative to outlets. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Functionalization of SBA-15 mesoporous silica by Cu-phosphonate units: Probing of synthesis route
DOE Office of Scientific and Technical Information (OSTI.GOV)
Laskowski, Lukasz, E-mail: lukasz.laskowski@kik.pcz.pl; Czestochowa University of Technology, Institute of Physics, Al. Armii Krajowej 19, 42-201 Czestochowa; Laskowska, Magdalena, E-mail: magdalena.laskowska@onet.pl
2014-12-15
Mesoporous silica SBA-15 containing propyl-copper phosphonate units was investigated. The structure of mesoporous samples was tested by N{sub 2} isothermal sorption (BET and BHJ analysis), TEM microscopy and X-Ray scattering. Quantitative analysis EDX has given information about proportions between component atoms in the sample. Quantitative elemental analysis has been carried out to support EDX. To examine bounding between copper atoms and phosphonic units the Raman spectroscopy was carried out. As a support of Raman scattering, the theoretical calculations were made based on density functional theory, with the B3LYP method. By comparison of the calculated vibrational spectra of the molecule withmore » experimental results, distribution of the active units inside silica matrix has been determined. - Graphical abstract: The present study is devoted to mesoporous silica SBA-15 containing propyl-copper phosphonate units. The species were investigated to confirm of synthesis procedure correctness by the micro-Raman technique combined with DFT numerical simulations. Complementary research was carried out to test the structure of mesoporous samples. - Highlights: • SBA-15 silica functionalized with propyl-copper phosphonate units was synthesized. • Synthesis efficiency probed by Raman study supported with DFT simulations. • Homogenous distribution of active units was proved. • Synthesis route enables precise control of distance between copper ions.« less
Kumar, Chandra M; Corbett, William A; Wilson, Robert G
2008-08-01
Extended spinal anaesthesia using a spinal micro-catheter was used as a primary method of anaesthesia for elective colorectal cancer surgery in 68 high risk patients over a 14-year period in our institution. The technique was also useful in eight elective and 13 emergency abdominal surgeries. All patients suffered from severe chronic obstructive airway disease requiring multiple inhalers and drugs (ASA III). Thirty nine of these patients also suffered from angina, myocardial infarction, diabetes and other systemic diseases (ASA IV). Surgery included right hemicolectomy, left hemicolectomy, total colectomy, sigmoid colectomy, Hartman's resection, anterior resection of rectum, abdominoperineal resection, cholecystectomy (open and laparoscopic) and obstructed inguinal hernia requiring laparotomy. Spinal anaesthesia was performed under strict aseptic conditions with a 22 gauge spinal needle with a mixture consisting of 2.75ml of 0.5% heavy bupivacaine and 0.25ml of fentanyl (25microg). This was followed by placement of a spinal micro-catheter and the duration of anaesthesia was extended by intermittent injection of 0.5% isobaric bupivacaine. Brief hypotension occurred in 12.4% of patients during the establishment of anaesthetic block height to T6-7 and was duly treated with intravenous administration of fluid and ephedrine hydrochloride. Good anaesthesia resulted in all patients except for brief discomfort in some patients during hemicolectomy surgery possibly due to the dissection and traction on the peritoneum causing irritation to the diaphragm. The use of sedation was avoided. General anaesthesia was administered in one patient and this patient required postoperative ventilation and cardiovascular support in the Intensive Care Unit. The spinal micro-catheter was removed at the end of surgery. Postoperative pain relief was obtained by administering intravenous morphine through a patient controlled analgesia machine in the critical care ward area (High Dependency Unit). There was a low incidence of minor postoperative side effects such as nausea (14.6%), vomiting (7.9%), minor post dural puncture headache (5.6%) and pruritus (5.6%). We conclude that spinal anaesthesia with a micro-catheter may be used as a primary method of anaesthesia for colorectal cancer surgery and other major abdominal surgery in high-risk patients for whom general anaesthesia would be associated with higher morbidity and mortality.
Dribe, Martin; Hacker, J. David; Scalone, Francesco
2014-01-01
Most previous work on the historical fertility transition has been macro-oriented, using aggregate data to examine economic correlates of demographic behaviour at regional or national levels, while much less has been done using micro data, and specifically looking at behavioural differentials among social groups. In this paper we study at the impact of socioeconomic status on net fertility during the fertility transition in five Northern American and European Countries (Canada, Iceland, Norway, Sweden and the USA). We use micro-level census data in 1900, containing information on number of children by age, occupation of the mother and father, place of residence and household context. The results show highly similar patterns across countries, with the elite and upper middle classes having considerably lower net fertility early in the transition. These patterns remain also after controlling for a range of individual and community-level fertility determinants and geographical unobserved heterogeneity. PMID:24684711
NASA Astrophysics Data System (ADS)
Yin, Ming; Xie, Luofeng; Jiang, Weifeng; Yin, Guofu
2018-05-01
Functional gradient systems have important applications in many areas. Although a 2D dielectric structure that serves as the gradient index medium for controlling electromagnetic waves is well established, it may not be suitable for application in 3D case. In this paper, we present a method to realize functional gradient systems with 3D integrated micro/macrostructure. The homogenization of the structure is studied in detail by conducting band diagram analysis. The analysis shows that the effective medium approximation is valid even when periodicity is comparable to wavelength. The condition to ensure the polarization-invariant, isotropic, and frequency-independent property is investigated. The scheme for the design and fabrication of 3D systems requiring spatial material property distribution is presented. By using the vat photopolymerization process, a large overall size of macrostructure at the system level and precise fine features of microstructure at the unit cell level are realized, thus demonstrating considerable scalability of the system for wave manipulation.
Three-dimensional macroporous nanoelectronic networks as minimally invasive brain probes
NASA Astrophysics Data System (ADS)
Xie, Chong; Liu, Jia; Fu, Tian-Ming; Dai, Xiaochuan; Zhou, Wei; Lieber, Charles M.
2015-12-01
Direct electrical recording and stimulation of neural activity using micro-fabricated silicon and metal micro-wire probes have contributed extensively to basic neuroscience and therapeutic applications; however, the dimensional and mechanical mismatch of these probes with the brain tissue limits their stability in chronic implants and decreases the neuron-device contact. Here, we demonstrate the realization of a three-dimensional macroporous nanoelectronic brain probe that combines ultra-flexibility and subcellular feature sizes to overcome these limitations. Built-in strains controlling the local geometry of the macroporous devices are designed to optimize the neuron/probe interface and to promote integration with the brain tissue while introducing minimal mechanical perturbation. The ultra-flexible probes were implanted frozen into rodent brains and used to record multiplexed local field potentials and single-unit action potentials from the somatosensory cortex. Significantly, histology analysis revealed filling-in of neural tissue through the macroporous network and attractive neuron-probe interactions, consistent with long-term biocompatibility of the device.
Issues regarding the usage of MPPT techniques in micro grid systems
NASA Astrophysics Data System (ADS)
Szeidert, I.; Filip, I.; Dragan, F.; Gal, A.
2018-01-01
The main objective of the control strategies applied at hybrid micro grid systems (wind/hydro/solar), that function based on maximum power point tracking (MPPT) techniques is to improve the conversion system’s efficiency and to preserve the quality of the generated electrical energy (voltage and power factor). One of the main goals of maximum power point tracking strategy is to achieve the harvesting of the maximal possible energy within a certain time period. In order to implement the control strategies for micro grid, there are typically required specific transducers (sensor for wind speed, optical rotational transducers, etc.). In the technical literature, several variants of the MPPT techniques are presented and particularized at some applications (wind energy conversion systems, solar systems, hydro plants, micro grid hybrid systems). The maximum power point tracking implementations are mainly based on two-level architecture. The lower level controls the main variable and the superior level represents the MPPT control structure. The paper presents micro grid structures developed at Politehnica University Timisoara (PUT) within the frame of a research grant. The paper is focused on the application of MPPT strategies on hybrid micro grid systems. There are presented several structures and control strategies and are highlighted their advantages and disadvantages, together with practical implementation guidelines.
MEASUREMENT OF WASTE LOADING IN SALTSTONE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harbour, J; Vickie Williams, V
2008-07-18
One of the goals of the Saltstone variability study is to identify the operational and compositional variables that control or influence the important processing and performance properties of Saltstone grout mixtures. One of those properties of importance is the Waste Loading (WL) of the decontaminated salt solution (DSS) in the Saltstone waste form. Waste loading is a measure of the amount of waste that can be incorporated within a waste form. The value of the Saltstone waste loading ultimately determines the number of vaults that will be required to disposition all of the DSS. In this report, the waste loadingmore » is defined as the volume in milliliters of DSS per liter of Saltstone waste form. The two most important parameters that determine waste loading for Saltstone are water to cementitious material (w/cm) ratio and the cured grout density. Data are provided that show the dependence of waste loading on the w/cm ratio for a fixed DSS composition using the current premix material (45% Blast Furnace Slag (BFS), 45% Fly Ash (FA) and 10% Ordinary Portland Cement (OPC)). The impact of cured grout density on waste loading was also demonstrated. Mixes (at 0.60 w/cm) made with a Modular Caustic side extraction Unit (MCU) simulant and either OPC or BFS have higher cured grout densities than mixes made with premix and increase the WL to 709 mL/L for the OPC mix and 689 mL/L for the BFS mix versus the value of 653 mL/L for MCU in premix at 0.60 w/cm ratio. Bleed liquid reduces the waste loading and lowers the effective w/cm ratio of Saltstone. A method is presented (and will be used in future tasks) for correcting the waste loading and the w/cm ratio of the as-batched mixes in those cases where bleed liquid is present. For example, the Deliquification, Dissolution and Adjustment (DDA) mix at an as-batched 0.60 w/cm ratio, when corrected for % bleed, gives a mix with a 0.55 w/cm ratio and a WL that has been reduced from 662 to 625 mL/L. An example is provided that demonstrated the quantitative impact of WL on the number of cells (each Saltstone vault contains two cells) required to disposition all of the {approx}100 million gallons of DSS available in the tanks. This calculation revealed that the number of cells required over the range of 0.48 to 0.62 w/cm ratio (equivalent to a WL range of 591 to 666 mL/L) varies from 65 to 57 cells (33 to 29 vaults). The intent of this oversimplified example was to show the range of variation in vaults expected due to w/cm ratio rather than to estimate the actual number of vaults required. There is a tradeoff between the waste loading and the processing and performance properties of Saltstone. The performance properties improve in general as the w/cm ratio decreases whereas the waste loading is reduced at lower w/cm ratios resulting in a larger number of Saltstone vaults. The final performance and processing requirements of Saltstone will determine the maximum waste loading achievable.« less
Effect of curing mode on the micro-mechanical properties of dual-cured self-adhesive resin cements.
Ilie, Nicoleta; Simon, Alexander
2012-04-01
Light supplying to luting resin cements is impeded in several clinical situations, causing us to question whether materials can properly be cured to achieve adequately (or adequate) mechanical properties. The aim of this study was therefore to analyse the effect of light on the micro-mechanical properties of eight popular dual-cured self-adhesive resin cements by comparing them with two conventional, also dual-cured, resin cements. Four different curing procedures were applied: auto-polymerisation (dark curing) and light curing (LED unit, Freelight 2, 20 s) by applying the unit directly on the samples' surface, at a distance of 5 and 10 mm. Twenty minutes after curing, the samples were stored for 1 week at 37°C in a water-saturated atmosphere. The micro-mechanical properties-Vickers hardness, modulus of elasticity, creep and elastic/plastic deformation-were measured. Data were analysed with multivariate ANOVA followed by Tukey's test and partial eta-squared statistics (p < 0.05). A very strong influence of the material as well as filler volume and weight on the micro-mechanical properties was measured, whereas the influence of the curing procedure and type of cement-conventional or self-adhesive-was generally low. The influence of light on the polymerisation process was material dependent, with four different behaviour patterns to be distinguished. As a material category, significantly higher micro-mechanical properties were measured for the conventional compared to the self-adhesive resin cements, although this difference was low. Within the self-adhesive resin cements group, the variation in micro-mechanical properties was high. The selection of suitable resin cements should be done by considering, besides its adhesive properties, its micro-mechanical properties and curing behaviour also.
Faruque, Imraan A; Muijres, Florian T; Macfarlane, Kenneth M; Kehlenbeck, Andrew; Humbert, J Sean
2018-06-01
This paper presents "optimal identification," a framework for using experimental data to identify the optimality conditions associated with the feedback control law implemented in the measurements. The technique compares closed loop trajectory measurements against a reduced order model of the open loop dynamics, and uses linear matrix inequalities to solve an inverse optimal control problem as a convex optimization that estimates the controller optimality conditions. In this study, the optimal identification technique is applied to two examples, that of a millimeter-scale micro-quadrotor with an engineered controller on board, and the example of a population of freely flying Drosophila hydei maneuvering about forward flight. The micro-quadrotor results show that the performance indices used to design an optimal flight control law for a micro-quadrotor may be recovered from the closed loop simulated flight trajectories, and the Drosophila results indicate that the combined effect of the insect longitudinal flight control sensing and feedback acts principally to regulate pitch rate.
A Cancer-Indicative microRNA Pattern in Normal Prostate Tissue
Hellwinkel, Olaf J. C.; Sellier, Christina; Sylvester, Yu-Mi Jessica; Brase, Jan C.; Isbarn, Hendrik; Erbersdobler, Andreas; Steuber, Thomas; Sültmann, Holger; Schlomm, Thorsten; Wagner, Christina
2013-01-01
We analyzed the levels of selected micro-RNAs in normal prostate tissue to assess their potential to indicate tumor foci elsewhere in the prostate. Histologically normal prostate tissue samples from 31 prostate cancer patients and two cancer negative control groups with either unsuspicious or elevated prostate specific antigen (PSA) levels (14 and 17 individuals, respectively) were analyzed. Based on the expression analysis of 157 microRNAs in a pool of prostate tissue samples and information from data bases/literature, we selected eight microRNAs for quantification by real-time polymerase chain reactions (RT-PCRs). Selected miRNAs were analyzed in histologically tumor-free biopsy samples from patients and healthy controls. We identified seven microRNAs (miR-124a, miR-146a & b, miR-185, miR-16 and let-7a & b), which displayed significant differential expression in normal prostate tissue from men with prostate cancer compared to both cancer negative control groups. Four microRNAs (miR-185, miR-16 and let-7a and let-7b) remained to significantly discriminate normal tissues from prostate cancer patients from those of the cancer negative control group with elevated PSA levels. The transcript levels of these microRNAs were highly indicative for the presence of cancer in the prostates, independently of the PSA level. Our results suggest a microRNA-pattern in histologically normal prostate tissue, indicating prostate cancer elsewhere in the organ. PMID:23459235
NASA Astrophysics Data System (ADS)
Morita, Written By Ichiko; Matsumura, Translated By Tamiko
Libraries in the United States are now experiencing another phase of rapid change brought by the sudden invasion of micro-computers. Their versatility has made available not only capabilities for word processing and producing spread sheets but also introduced new approaches to large research libraries’ information networks. OCLC’s microenhancers are one example of what is now available. They can be used for retrospective conversion, provide instruction for the use of and function as front end terminals for large online catalogs. Various new ideas for the application of micro-computers will bring interesting developments in library automation.
NASA Astrophysics Data System (ADS)
Liu, Yueming; Tian, Weijian; Zhang, Shaojun
2009-05-01
Soft and flexible grating sensing waveguides is urgently demanded in application of micro-bending sensing and surface distortion sensing in medical catheter and smart skin sensing unit etc. Based on Nano-imprint Lithography and micro-replication process, polymer grating waveguides with core size 4μm×20μm and pitch 0.75μm are fabricated successfully in this paper. This novel grating waveguides is soft and flexible enough for related application and with the bio-medical safe feature when used in human body catheter. Fabricated processes are presented including the fabrication of micro mould and UV-replication process, and relative skills are discussed also in this paper.
Sensor-less force-reflecting macro-micro telemanipulation systems by piezoelectric actuators.
Amini, H; Farzaneh, B; Azimifar, F; Sarhan, A A D
2016-09-01
This paper establishes a novel control strategy for a nonlinear bilateral macro-micro teleoperation system with time delay. Besides position and velocity signals, force signals are additionally utilized in the control scheme. This modification significantly improves the poor transparency during contact with the environment. To eliminate external force measurement, a force estimation algorithm is proposed for the master and slave robots. The closed loop stability of the nonlinear micro-micro teleoperation system with the proposed control scheme is investigated employing the Lyapunov theory. Consequently, the experimental results verify the efficiency of the new control scheme in free motion and during collision between the slave robot and the environment of slave robot with environment, and the efficiency of the force estimation algorithm. Copyright © 2016 ISA. Published by Elsevier Ltd. All rights reserved.
Riancho, Javier; Vázquez-Higuera, José Luis; Pozueta, Ana; Lage, Carmen; Kazimierczak, Martha; Bravo, María; Calero, Miguel; Gonalezález, Andrea; Rodríguez, Eloy; Lleó, Alberto; Sánchez-Juan, Pascual
2017-01-01
MicroRNAs have been postulated as potential biomarkers for Alzheimer's disease (AD). Exosomes are nanovesicles which transport microRNAs, proteins, and other cargos. It has been hypothesized that the exosome traffic might be increased in neurodegenerative disorders. i) To assess the cerebrospinal fluid (CSF) microRNA profile in a group of AD patients and control subjects and to validate a group of microRNAs previously reported by other authors. ii) To compare microRNA levels in whole CSF and in the exosome-enriched fraction in AD patients. A panel of 760 microRNAs was analyzed in the CSF of 10 AD patients and 10 healthy subjects. Among microRNAs differently expressed, we selected those that had been previously reported by other authors. Candidates were validated in a larger group by individual qPCR assays. MicroRNA expression was also evaluated in exosome-enriched CSF samples of patients with AD and controls. Fifteen microRNAs were differently expressed in AD. MiR-9-5p, miR-134, and miR-598 were selected as candidates for further analysis. MiR-9-5p and miR-598 were detected in 50 and 75% of control CSF samples, respectively, while they were not detected in any AD CSF samples. We observed an opposite pattern when we evaluated the microRNA expression in the exosome-enriched CSF AD samples. No pattern variations were noted among healthy subjects. These data propose miR-9-5p and miR-598 as potential biomarkers for AD. Further studies in plasma and other body fluids will confirm their potential role as easily accessible biomarkers. In addition, our data suggest that exosome trafficking is different between AD and control subjects raising the need to take this phenomenon into consideration in future studies of AD biomarkers.
NASA Astrophysics Data System (ADS)
Nafis, Christopher; Jensen, Vern; von Jako, Ron
2008-03-01
Electromagnetic (EM) tracking systems have been successfully used for Surgical Navigation in ENT, cranial, and spine applications for several years. Catheter sized micro EM sensors have also been used in tightly controlled cardiac mapping and pulmonary applications. EM systems have the benefit over optical navigation systems of not requiring a line-of-sight between devices. Ferrous metals or conductive materials that are transient within the EM working volume may impact tracking performance. Effective methods for detecting and reporting EM field distortions are generally well known. Distortion compensation can be achieved for objects that have a static spatial relationship to a tracking sensor. New commercially available micro EM tracking systems offer opportunities for expanded image-guided navigation procedures. It is important to know and understand how well these systems perform with different surgical tables and ancillary equipment. By their design and intended use, micro EM sensors will be located at the distal tip of tracked devices and therefore be in closer proximity to the tables. Our goal was to define a simple and portable process that could be used to estimate the EM tracker accuracy, and to vet a large number of popular general surgery and imaging tables that are used in the United States and abroad.
The Effect of Micro-ramps on Supersonic Flow over a Forward-Facing Step
NASA Astrophysics Data System (ADS)
Zhang, Qing-Hu; Yi, Shi-He; Zhu, Yang-Zhu; Chen, Zhi; Wu, Yu
2013-04-01
The effect of micro-ramp control on fully developed turbulent flow over a forward-facing step (FFS) is investigated in a supersonic low-noise wind tunnel at Mach number 3 using nano-tracer planar laser scattering (NPLS) and supersonic particle image velocimetry (PIV) techniques. High spatiotemporal resolution images and the average velocity profiles of supersonic flow over the FFS with and without the control of the micro-ramps are captured. The fine structures of both cases, including the coherent structures of fully developed boundary layer and the large-scale hairpin-like vortices originated from the micro-ramps as well as the interaction of shock waves with the large-scale structures, are revealed and compared. Based on the time-correlation images, the temporal and spatial evolutionary characteristics of the coherent structures are investigated. It is beneficial to understand the dynamic mechanisms of the separated flow and the control mechanisms of the micro-ramps. The size of the separation region is determined by the NPLS and PIV. The results indicate that the control of the micro-ramps is capable of delaying the separation and diminishing the extent of recirculation zone.
[Microbiological verification of a self control plan for a hospital food service].
Torre, I; Pennino, F; Crispino, M
2006-01-01
During the past years, it has been an increment of food related infectious diseases. In order to avoid micro biological food contamination, adherence to good manufacturing is required through control measures of food safety practices. Updated national and European regulations underline the need to apply the HACCP system, overcoming the old concept of sample control on the end user product. This work shows results of microbiological controls made along the whole productive chain. Measurements are made using biomolecular techniques (PFGE) in order to assess the management of the micro biological risk of the self control plan applied to a hospital food service of Naples. The use of the PFGE applied on some micro-organisms gram negative potentially pathogen, underlines the circulation, continued in time, of these micro-organisms within the cooking area. In addition, cross contamination between several matrixes of samples has been detected.
Micro CT characterization of a coastal mine tailings deposit, Portmán Bay, SE Spain
NASA Astrophysics Data System (ADS)
Frigola, Jaime; Cerdà-Domènech, Marc; Barriuso, Eduardo; Sanchez-Vidal, Anna; Amblas, David; Canals, Miquel
2017-04-01
Scanning of sediment cores by means of high-resolution non-destructive techniques provides researchers with huge amounts of highly valuable data allowing fast and detailed characterization of the materials. In the last decades several devoted instruments have been developed and applied to the study of sedimentary sequences, mainly multi-sensor core loggers (MSCL) for the physical properties and XRF core scanners for the chemical elemental composition. The geoscientific community started using computed tomography (CT) systems about two decades ago. These were mainly medical systems as dedicated instruments were essentially lacking by that time. The resolution of those medical systems was limited to several hundreds of micrometres voxel size. Micro computed tomography (micro-CT) systems have also spread into geoscientific research, although their limited workspace dimensions prevents their use for large objects, such as long sediment cores. Recently, a new micro-CT system, the MultiTom Core X-ray CT, conceived by University of Barcelona (UB) researchers and developed by X-ray Engineering, became operational. It is able of scanning sediment cores up to 1.5 m long, and allows adjustable resolutions from 300 microns down to 3-4 microns. The system is now installed at UB's CORELAB Laboratory for non-destructive analyses of geological materials. Here we present, as an example, the results of MultiTom scans of a set of sediment cores recovered offshore Portmán Bay, SE Spain, in order to characterize at very high-resolution the metal-enriched deposit generated after 33 years of direct discharge into the sea of mine tailings resulting from the exploitation of Pb and Zn ores. In total 52 short cores and 6 long gravity cores from the mine tailings infilled bay were scanned with the MultiTom system at a mean voxel resolution of 125 microns. The integrated study of micro-CT data allowed differentiating the main tailings units from deposits formed after disposal cessation. Tailings units show higher radio-density values, which correspond to metal enrichments. A lower unit consists of highly laminated interbedded low radio-density and very high radio-density layers, while an upper mine tailings unit is more homogeneous and shows intermediate radio-density values. The limit between the tailings and the post-mining deposits is defined by a sharp surface associated with an abrupt decrease in the radio-densities. Post-mining deposits are also characterized by an increment in bioturbation marks, which are practically absent in the tailings units, and an increase in carbonate particles and organic matter patches. Micro CT scans allow observation of very small structures, which are indicative of the complexity of the sedimentation processes involved in the transport and final deposition of the mine tailings. Integration of micro CT scans together with XRF core scanner and MSCL data allows a better characterization of the metal concentrations and their distribution within the deposit, directly demonstrating the great value of non-destructive techniques for actually high-resolution sedimentological studies.
2016-10-28
assumptions. List of Assumptions: Price of electrical energy : $0.07/kWh flat rate for energy at the base Price of peak power: $15/MW peak power...EW-201147) Advanced Micro-Grid Energy Management Coupled with Integrated Volt/VAR Control for Improved Energy Efficiency, Energy Security, and...12-C-0002 5b. GRANT NUMBER Advanced Micro-Grid Energy Management Coupled with Integrated Volt/VAR Control for Improved Energy Efficiency, Energy
Unbalanced voltage control of virtual synchronous generator in isolated micro-grid
NASA Astrophysics Data System (ADS)
Cao, Y. Z.; Wang, H. N.; Chen, B.
2017-06-01
Virtual synchronous generator (VSG) control is recommended to stabilize the voltage and frequency in isolated micro-grid. However, common VSG control is challenged by widely used unbalance loads, and the linked unbalance voltage problem worsens the power quality of the micro-grid. In this paper, the mathematical model of VSG was presented. Based on the analysis of positive- and negative-sequence equivalent circuit of VSG, an approach was proposed to eliminate the negative-sequence voltage of VSG with unbalance loads. Delay cancellation method and PI controller were utilized to identify and suppress the negative-sequence voltages. Simulation results verify the feasibility of proposed control strategy.
A wireless high-speed data acquisition system for geotechnical centrifuge model testing
NASA Astrophysics Data System (ADS)
Gaudin, C.; White, D. J.; Boylan, N.; Breen, J.; Brown, T.; DeCatania, S.; Hortin, P.
2009-09-01
This paper describes a novel high-speed wireless data acquisition system (WDAS) developed at the University of Western Australia for operation onboard a geotechnical centrifuge, in an enhanced gravitational field of up to 300 times Earth's gravity. The WDAS system consists of up to eight separate miniature units distributed around the circumference of a 0.8 m diameter drum centrifuge, communicating with the control room via wireless Ethernet. Each unit is capable of powering and monitoring eight instrument channels at a sampling rate of up to 1 MHz at 16-bit resolution. The data are stored within the logging unit in solid-state memory, but may also be streamed in real-time at low frequency (up to 10 Hz) to the centrifuge control room, via wireless transmission. The high-speed logging runs continuously within a circular memory (buffer), allowing for storage of a pre-trigger segment of data prior to an event. To suit typical geotechnical modelling applications, the system can record low-speed data continuously, until a burst of high-speed acquisition is triggered when an experimental event occurs, after which the system reverts back to low-speed acquisition to monitor the aftermath of the event. Unlike PC-based data acquisition solutions, this system performs the full sequence of amplification, conditioning, digitization and storage on a single circuit board via an independent micro-controller allocated to each pair of instrumented channels. This arrangement is efficient, compact and physically robust to suit the centrifuge environment. This paper details the design specification of the WDAS along with the software interface developed to control the units. Results from a centrifuge test of a submarine landslide are used to illustrate the performance of the new WDAS.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chukbar, B. K., E-mail: bchukbar@mail.ru
Two methods of modeling a double-heterogeneity fuel are studied: the deterministic positioning and the statistical method CORN of the MCU software package. The effect of distribution of microfuel in a pebble bed on the calculation results is studied. The results of verification of the statistical method CORN for the cases of the microfuel concentration up to 170 cm{sup –3} in a pebble bed are presented. The admissibility of homogenization of the microfuel coating with the graphite matrix is studied. The dependence of the reactivity on the relative location of fuel and graphite spheres in a pebble bed is found.
Cirrus Particle Distribution Study. Part 6
1980-09-04
b 546- 0 W N . 0. 655- 0.4 M.5.41fl U MCU n 104 N fU% OMMN (O 0 0 W 5.5 P)D. %n ))UUU U) M) I. W52 ,Ir N.4 C’,00 )00 ))5’)) I) U ISO ~-1 04 OC O CfC... 27001 ’f400 0 C 0 ;: 30 ~ of a. 0.87 a4444 00 P N * . .’ .~. .44...0 0 . L;8’ 0 8-08 a n 0P " o0os, -O M C t0 2i Ws, 2,W-’ NM2r-r ~ OW0 0W I -Vf 0VW roe
PROGRAMMABLE DISPLAY PUSHBUTTON LEGEND EDITOR
NASA Technical Reports Server (NTRS)
Busquets, A. M.
1994-01-01
The Programmable Display Pushbutton (PDP) is a pushbutton device available from Micro Switch which has a programmable 16 x 35 matrix of LEDs on the pushbutton surface. Any desired legends can be displayed on the PDPs, producing user-friendly applications which greatly reduce the need for dedicated manual controls. Because the PDP can interact with the operator, it can call for the correct response before transmitting its next message. It is both a simple manual control and a sophisticated programmable link between the operator and the host system. The Programmable Display Pushbutton Legend Editor, PDPE, is used to create the LED displays for the pushbuttons. PDPE encodes PDP control commands and legend data into message byte strings sent to a Logic Refresh and Control Unit (LRCU). The LRCU serves as the driver for a set of four PDPs. The legend editor (PDPE) transmits to the LRCU user specified commands that control what is displayed on the LED face of the individual pushbuttons. Upon receiving a command, the LRCU transmits an acknowledgement that the message was received and executed successfully. The user then observes the effect of the command on the PDP displays and decides whether or not to send the byte code of the message to a data file so that it may be called by an applications program. The PDPE program is written in FORTRAN for interactive execution. It was developed on a DEC VAX 11/780 under VMS. It has a central memory requirement of approximately 12800 bytes. It requires four Micro Switch PDPs and two RS-232 VAX 11/780 terminal ports. The PDPE program was developed in 1985.
Campanelli, Sabina L.; Contuzzi, Nicola; Ludovico, Antonio D.; Caiazzo, Fabrizia; Cardaropoli, Francesco; Sergi, Vincenzo
2014-01-01
The paper investigates the fabrication of Selective Laser Melting (SLM) titanium alloy Ti6Al4V micro-lattice structures for the production of lightweight components. Specifically, the pillar textile unit cell is used as base lattice structure and alternative lattice topologies including reinforcing vertical bars are also considered. Detailed characterizations of dimensional accuracy, surface roughness, and micro-hardness are performed. In addition, compression tests are carried out in order to evaluate the mechanical strength and the energy absorbed per unit mass of the lattice truss specimens made by SLM. The built structures have a relative density ranging between 0.2234 and 0.5822. An optimization procedure is implemented via the method of Taguchi to identify the optimal geometric configuration which maximizes peak strength and energy absorbed per unit mass. PMID:28788707
Zacour, Brian M; Pandey, Preetanshu; Subramanian, Ganeshkumar; Gao, Julia Z; Nikfar, Faranak
2014-06-01
The objective of this study was to determine the impact that the micro-environment, as measured by PyroButton data loggers, experienced by tablets during the pan coating unit operation had on the layer adhesion of bilayer tablets in open storage conditions. A full factorial design of experiments (DOE) with three center points was conducted to study the impact of final tablet hardness, film coating spray rate and film coating exhaust temperature on the delamination tendencies of bilayer tablets. PyroButton data loggers were placed (fixed) at various locations in a pan coater and were also allowed to freely move with the tablet bed to measure the micro-environmental temperature and humidity conditions of the tablet bed. The variance in the measured micro-environment via PyroButton data loggers accounted for 75% of the variance in the delamination tendencies of bilayer tablets on storage (R(2 )= 0.75). A survival analysis suggested that tablet hardness and coating spray rate significantly impacted the delamination tendencies of the bilayer tablets under open storage conditions. The coating exhaust temperature did not show good correlation with the tablets' propensity to crack indicating that it was not representative of the coating micro-environment. Models created using data obtained from the PyroButton data loggers outperformed models created using primary DOE factors in the prediction of bilayer tablet strength, especially upon equipment or scale transfers. The coating micro-environment experienced by tablets during the pan coating unit operation significantly impacts the strength of the bilayer interface of tablets on storage.
MEMS based pumped liquid cooling systems for micro/nano spacecraft thermal control
NASA Technical Reports Server (NTRS)
Birur, G. C.; Shakkottai, P.; Sur, T. W.
2000-01-01
The electronic and other payload power densities in future micro/nano spacecraft are expected to exceed 25 Watts/cm(sup 2) and require advanced thermal control concepts and technologies to keep their payload within allowable temperature limits. This paper presents background on the need for pumped liquid cooling systems for future micro/nano spacecraft and results from this ongoing experimental investigation.
Wyatt, S K; Barck, K H; Kates, L; Zavala-Solorio, J; Ross, J; Kolumam, G; Sonoda, J; Carano, R A D
2015-11-01
The ability to non-invasively measure body composition in mouse models of obesity and obesity-related disorders is essential for elucidating mechanisms of metabolic regulation and monitoring the effects of novel treatments. These studies aimed to develop a fully automated, high-throughput micro-computed tomography (micro-CT)-based image analysis technique for longitudinal quantitation of adipose, non-adipose and lean tissue as well as bone and demonstrate utility for assessing the effects of two distinct treatments. An initial validation study was performed in diet-induced obesity (DIO) and control mice on a vivaCT 75 micro-CT system. Subsequently, four groups of DIO mice were imaged pre- and post-treatment with an experimental agonistic antibody specific for anti-fibroblast growth factor receptor 1 (anti-FGFR1, R1MAb1), control immunoglobulin G antibody, a known anorectic antiobesity drug (rimonabant, SR141716), or solvent control. The body composition analysis technique was then ported to a faster micro-CT system (CT120) to markedly increase throughput as well as to evaluate the use of micro-CT image intensity for hepatic lipid content in DIO and control mice. Ex vivo chemical analysis and colorimetric analysis of the liver triglycerides were performed as the standard metrics for correlation with body composition and hepatic lipid status, respectively. Micro-CT-based body composition measures correlate with ex vivo chemical analysis metrics and enable distinction between DIO and control mice. R1MAb1 and rimonabant have differing effects on body composition as assessed by micro-CT. High-throughput body composition imaging is possible using a modified CT120 system. Micro-CT also provides a non-invasive assessment of hepatic lipid content. This work describes, validates and demonstrates utility of a fully automated image analysis technique to quantify in vivo micro-CT-derived measures of adipose, non-adipose and lean tissue, as well as bone. These body composition metrics highly correlate with standard ex vivo chemical analysis and enable longitudinal evaluation of body composition and therapeutic efficacy monitoring.
Assessing consumption of bioactive micro-particles by filter-feeding Asian carp
Jensen, Nathan R.; Amberg, Jon J.; Luoma, James A.; Walleser, Liza R.; Gaikowski, Mark P.
2012-01-01
Silver carp Hypophthalmichthys molitrix (SVC) and bighead carp H. nobilis (BHC) have impacted waters in the US since their escape. Current chemical controls for aquatic nuisance species are non-selective. Development of a bioactive micro-particle that exploits filter-feeding habits of SVC or BHC could result in a new control tool. It is not fully understood if SVC or BHC will consume bioactive micro-particles. Two discrete trials were performed to: 1) evaluate if SVC and BHC consume the candidate micro-particle formulation; 2) determine what size they consume; 3) establish methods to evaluate consumption of filter-feeders for future experiments. Both SVC and BHC were exposed to small (50-100 μm) and large (150-200 μm) micro-particles in two 24-h trials. Particles in water were counted electronically and manually (microscopy). Particles on gill rakers were counted manually and intestinal tracts inspected for the presence of micro-particles. In Trial 1, both manual and electronic count data confirmed reductions of both size particles; SVC appeared to remove more small particles than large; more BHC consumed particles; SVC had fewer overall particles in their gill rakers than BHC. In Trial 2, electronic counts confirmed reductions of both size particles; both SVC and BHC consumed particles, yet more SVC consumed micro-particles compared to BHC. Of the fish that ate micro-particles, SVC consumed more than BHC. It is recommended to use multiple metrics to assess consumption of candidate micro-particles by filter-feeders when attempting to distinguish differential particle consumption. This study has implications for developing micro-particles for species-specific delivery of bioactive controls to help fisheries, provides some methods for further experiments with bioactive micro-particles, and may also have applications in aquaculture.
Recent Results from the MicroMAS Global Environmental MonitoringNanosatellite Mission
NASA Astrophysics Data System (ADS)
Blackwell, W. J.; Cahoy, K.
2014-12-01
The Micro-sized Microwave Atmospheric Satellite (MicroMAS) is a dual-spinning 3U CubeSat equipped with apassive microwave radiometer that observes in nine channels near the 118.75-GHz oxygen absorption line.MicroMAS is designed to observe convective thunderstorms, tropical cyclones, and hurricanes from a midinclinationorbit. The MicroMAS flight unit was developed by MIT Lincoln Laboratory and the MIT Space SystemsLaboratory and was launched to the International Space Station on July 13, 2014, and scheduled for an earlySeptember deployment for a ~90-day mission. The payload is housed in the "lower" 1U of the dual-spinning 3UCubeSat and mechanically rotated approximately once per second as the spacecraft orbits the Earth, resulting in across-track scanned beam with a full-width half-max (FWHM) beamwidth of 2.4 degrees and an approximately 17-km diameter footprint at nadir incidence from a nominal altitude of 400 km. The relatively low cost of MicroMASenables the deployment of a constellation of sensors, spaced equally around several orbit planes. A small fleet ofMicroMAS systems could yield high-resolution global temperature and water vapor profiles, as well as cloudmicrophysical and precipitation parameters.Significant advancements were made in the Assembly, Integration, and Test phase of the project developmentlifecycle. The flight software and communications architecture was refined and tested in relevant lab facilities. Thepower subsystem was modified to include additional required inhibits for the ISS launch. Hardware in the loop testsas well as simulations of the attitude determination and control system (ADCS) were performed to validate theunique dual-spinning, local vertical, local horizontal (LVLH) stabilized flight design. ADCS algorithms were testedon a 3-axis air bearing and custom rig inside a 3-axis programmable Helmholtz cage. Finally, the integratedspacecraft underwent a series of environmental tests in order to verify the results of thermal modeling analyses,prove the performance of critical design components in relevant environmental conditions, and validate the softwareand concept-of-operations developed for flight. We present these advancements, lessons-learned in developing ascience-oriented CubeSat system, and any available launch/on-orbit updates.
Paediatric dose reduction with the introduction of digital fluorography.
Mooney, R B; McKinstry, J
2001-01-01
Fluoroscopy guided examinations in a paediatric X ray department were initially carried out on a unit that used a conventional screen-film combination for spot-films. A new fluoroscopy unit was installed with the facilities of digital fluorography and last image hold. Comparison of equipment performance showed that the dose per image for screen-film and digital fluorography was 3 microGy and 0.4 microGy, respectively. Although the screen-film had superior image quality, the department's radiologist confirmed that digital fluorography provided a diagnostic image. Patient dose measurements showed that introduction of the new unit caused doses to fall by an average of 70%, although fluoroscopy time had not changed significantly. The new unit produced 40% less air kerma during fluoroscopy. The remaining 30% reduction in dose was due to the introduction of digital fluorography and last image hold facilities. It is concluded that the use of digital fluorography can be an effective way of reducing paediatric dose.
NASA Astrophysics Data System (ADS)
Chen, Yuan-Liu; Xu, Yanhao; Shimizu, Yuki; Matsukuma, Hiraku; Gao, Wei
2018-06-01
This paper presents a high quality-factor (Q-factor) quartz tuning fork (QTF) with a glass probe attached, used in frequency modulation tapping mode atomic force microscopy (AFM) for the surface profile metrology of micro and nanostructures. Unlike conventionally used QTFs, which have tungsten or platinum probes for tapping mode AFM, and suffer from a low Q-factor influenced by the relatively large mass of the probe, the glass probe, which has a lower density, increases the Q-factor of the QTF probe unit allowing it to obtain better measurement sensitivity. In addition, the process of attaching the probe to the QTF with epoxy resin, which is necessary for tapping mode AFM, is also optimized to further improve the Q-factor of the QTF glass probe. The Q-factor of the optimized QTF glass probe unit is demonstrated to be very close to that of a bare QTF without a probe attached. To verify the effectiveness and the advantages of the optimized QTF glass probe unit, the probe unit is integrated into a home-built tapping mode AFM for conducting surface profile measurements of micro and nanostructures. A blazed grating with fine tool marks of 100 nm, a microprism sheet with a vertical amplitude of 25 µm and a Fresnel lens with a steep slope of 90 degrees are used as measurement specimens. From the measurement results, it is demonstrated that the optimized QTF glass probe unit can achieve higher sensitivity as well as better stability than conventional probes in the measurement of micro and nanostructures.
Dysregulation of serum microRNA-574-3p and its clinical significance in hepatocellular carcinoma.
Shen, Xianjuan; Xue, Yajing; Cong, Hui; Wang, Xudong; Ju, Shaoqing
2018-07-01
Objectives To explore microRNA-574-3p expression in serum of patients with hepatocellular carcinoma and investigate correlations between serum microRNA-574-3p expression and the development and prognosis of hepatocellular carcinoma. Design and methods Serum samples were collected from 70 patients with primary hepatocellular carcinoma, 40 patients with cirrhosis and 45 healthy controls. Serum microRNA-574-3p expression levels were detected by real-time quantitative polymerase chain reaction. The linearity, specificity and reproducibility were evaluated. In addition, the diagnostic value of microRNA-574-3p and its correlations with clinicopathologic features were assessed. Results The relative expression of microRNA-574-3p in hepatocellular carcinoma patients, cirrhosis patients and healthy controls was 2.306 (1.801-3.130), 1.362 (0.994-1.665) and 1.263 (0.765-1.723), respectively, indicating that it was significantly higher in hepatocellular carcinoma patients than that in the other two groups ( U = 439.5, 514.5, both P < 0.0001) and was significantly correlated with hepatitis B virus DNA copies ( U = 383.0, P = 0.018). In hepatitis B virus-positive hepatocellular carcinoma patients, the relative expression of microRNA-574-3p was significantly correlated with hepatitis B virus DNA concentration ( r = 0.348, P = 0.022). Compared with healthy control group, AUC ROC of serum microRNA-574-3p in hepatocellular carcinoma group was 0.837 with 95% CI: 0.763-0.910. Combining microRNA-574-3p, AFU and alpha-fetoprotein together, the sensitivity was highest compared with other markers alone or combined. Conclusions The relative expression of serum microRNA-574-3p in hepatocellular carcinoma patients was significantly higher than that in cirrhosis patients and healthy controls, and it may be an important biomarker in the auxiliary diagnosis of hepatocellular carcinoma.
Photothermal generation of microbubbles on plasmonic nanostructures inside microfluidic channels
NASA Astrophysics Data System (ADS)
Li, Jingting; Li, Ming; Santos, Greggy M.; Zhao, Fusheng; Shih, Wei-Chuan
2016-03-01
Microbubbles have been utilized as micro-pumps, micro-mixers, micro-valves, micro-robots and surface cleaners. Various generation techniques can be found in the literature, including resistive heating, hydrodynamic methods, illuminating patterned metal films and noble metal nanoparticles of Au or Ag. We present photothermal microbubble generation by irradiating nanoporous gold disk covered microfluidic channels. The size of the microbubble can be controlled by adjusting the laser power. The dynamics of both bubble growth and shrinkage are studied. The advantages of this technique are flexible bubble generation locations, long bubble lifetimes, no need for light-adsorbing dyes, high controllability over bubble size, low power consumption, etc. This technique has the potential to provide new flow control functions in microfluidic devices.
Micro-controller based air pressure monitoring instrumentation system using optical fibers as sensor
NASA Astrophysics Data System (ADS)
Hazarika, D.; Pegu, D. S.
2013-03-01
This paper describes a micro-controller based instrumentation system to monitor air pressure using optical fiber sensors. The principle of macrobending is used to develop the sensor system. The instrumentation system consists of a laser source, a beam splitter, two multi mode optical fibers, two Light Dependent Resistance (LDR) based timer circuits and a AT89S8252 micro-controller. The beam splitter is used to divide the laser beam into two parts and then these two beams are launched into two multi mode fibers. One of the multi mode fibers is used as the sensor fiber and the other one is used as the reference fiber. The use of the reference fiber is to eliminate the environmental effects while measuring the air pressure magnitude. The laser beams from the sensor and reference fibers are applied to two identical LDR based timer circuits. The LDR based timer circuits are interfaced to a micro-controller through its counter pins. The micro-controller samples the frequencies of the timer circuits using its counter-0 and counter-1 and the counter values are then processed to provide the measure of air pressure magnitude.
Preliminary design of mesoscale turbocompressor and rotordynamics tests of rotor bearing system
NASA Astrophysics Data System (ADS)
Hossain, Md Saddam
2011-12-01
A mesoscale turbocompressor spinning above 500,000 RPM is evolutionary technology for micro turbochargers, turbo blowers, turbo compressors, micro-gas turbines, auxiliary power units, etc for automotive, aerospace, and fuel cell industries. Objectives of this work are: (1) to evaluate different air foil bearings designed for the intended applications, and (2) to design & perform CFD analysis of a micro-compressor. CFD analysis of shrouded 3-D micro compressor was conducted using Ansys Bladegen as blade generation tool, ICEM CFD as mesh generation tool, and CFX as main solver for different design and off design cases and also for different number of blades. Comprehensive experimental facilities for testing the turbocompressor system have been also designed and proposed for future work.
Soft Real-Time PID Control on a VME Computer
NASA Technical Reports Server (NTRS)
Karayan, Vahag; Sander, Stanley; Cageao, Richard
2007-01-01
microPID (uPID) is a computer program for real-time proportional + integral + derivative (PID) control of a translation stage in a Fourier-transform ultraviolet spectrometer. microPID implements a PID control loop over a position profile at sampling rate of 8 kHz (sampling period 125microseconds). The software runs in a strippeddown Linux operating system on a VersaModule Eurocard (VME) computer operating in real-time priority queue using an embedded controller, a 16-bit digital-to-analog converter (D/A) board, and a laser-positioning board (LPB). microPID consists of three main parts: (1) VME device-driver routines, (2) software that administers a custom protocol for serial communication with a control computer, and (3) a loop section that obtains the current position from an LPB-driver routine, calculates the ideal position from the profile, and calculates a new voltage command by use of an embedded PID routine all within each sampling period. The voltage command is sent to the D/A board to control the stage. microPID uses special kernel headers to obtain microsecond timing resolution. Inasmuch as microPID implements a single-threaded process and all other processes are disabled, the Linux operating system acts as a soft real-time system.
NASA Astrophysics Data System (ADS)
Radziszewska, Weronika; Nahorski, Zbigniew
An Energy Management System (EMS) for a small microgrid is presented, with both demand and production side management. The microgrid is equipped with renewable and controllable power sources (like a micro gas turbine), energy storage units (batteries and flywheels). Energy load is partially scheduled to avoid extreme peaks of power demand and to possibly match forecasted energy supply from the renewable power sources. To balance the energy in the network on line, a multiagent system is used. Intelligent agents of each device are proactively acting towards balancing the energy in the network, and at the same time optimizing the cost of operation of the whole system. A semi-market mechanism is used to match a demand and a production of the energy. Simulations show that the time of reaching a balanced state does not exceed 1 s, which is fast enough to let execute proper balancing actions, e.g. change an operating point of a controllable energy source. Simulators of sources and consumption devices were implemented in order to carry out exhaustive tests.
Chen, Bin; Xiao, Wei; Jia, Xiao-Bin; Huang, Yang
2012-07-01
To prepare Danshen phenolic acid fast release micro-pellets and study its preparation craft. The factors which could impact yield, extrude shaping, dissolution of Danshen phenolic acid micro-pellets such as wetting agent, drug loading dose, adjuvant, lactose dose, disintegrant, CMS-Na dose and wetting agent dose was investigated. The optimum preparation craft of Danshen phenolic acid fast release micro-pellets was screened out by orhogonal design. Formula of Danshen phenolic acid fast release micro-pellets was calculated as volume dose 50 g. The formula was as follows: principal agent 22.5 g, lactose 5 g, CMS-Na 2 g, MCC 20.5 g, 27 mL 30% ethanol as wetting agent. Extrusion-spheronization was applied. The optimum conditions were screened out as follows: extrusion frequency (25 Hz), spheronization machine frequency (50 Hz), spheronization time (4 min). The process was scientific and rational. The preparation is stable settles basis for multi-drug delivery system of Tongmai micro-pellets.
A force-controllable macro-micro manipulator and its application to medical robots
NASA Technical Reports Server (NTRS)
Marzwell, Neville I.; Uecker, Darrin R.; Wang, Yulun
1994-01-01
This paper describes an 8-degrees-of-freedom macro-micro robot. This robot is capable of performing tasks that require accurate force control, such as polishing, finishing, grinding, deburring, and cleaning. The design of the macro-micro mechanism, the control algorithms, and the hardware/software implementation of the algorithms are described in this paper. Initial experimental results are reported. In addition, this paper includes a discussion of medical surgery and the role that force control may play. We introduce a new class of robotic systems collectively called Robotic Enhancement Technology (RET). RET systems introduce the combination of robotic manipulation with human control to perform manipulation tasks beyond the individual capability of either human or machine. The RET class of robotic systems offers new challenges in mechanism design, control-law development, and man/machine interface design. We believe force-controllable mechanisms such as the macro-micro structure we have developed are a necessary part of RET. Work in progress in the area of RET systems and their application to minimally invasive surgery is presented, along with future research directions.
Carbon Nanotube Bolometer for Absolute FTIR Spectroscopy
NASA Astrophysics Data System (ADS)
Woods, Solomon; Neira, Jorge; Tomlin, Nathan; Lehman, John
We have developed and calibrated planar electrical-substitution bolometers which employ absorbers made from vertically-aligned carbon nanotube arrays. The nearly complete absorption of light by the carbon nanotubes from the visible range to the far-infrared can be exploited to enable a device with read-out in native units equivalent to optical power. Operated at cryogenic temperatures near 4 K, these infrared detectors are designed to have time constant near 10 ms and a noise floor of about 10 pW. Built upon a micro-machined silicon platform, each device has an integrated heater and thermometer, either a carbon nanotube thermistor or superconducting transition edge sensor, for temperature control. We are optimizing temperature-controlled measurement techniques to enable high resolution spectral calibrations using these devices with a Fourier-transform spectrometer.
NASA Astrophysics Data System (ADS)
Kordyum, V. A.; Man'ko, V. G.; Popova, A. F.; Shcherbak, O. H.; Mashinsky, A. L.; Nguen-Hgue-Thyok
The miniature cenosis consisting of the water fern Azolla with its associated symbiotic nitrogen-fixing cyanobacterium Anabaena and the concomitant bacteria was investigated. Ecological closure was shown to produce sharp quantitative and qualitative changes in the number and type of concomitant bacteria. Changes in the distribution of bacterial types grown on beef-extract broth after space flight were recorded. Anabaena azollae underwent the most significant changes under spaceflight conditions. Its cell number per Azolla biomass unit increased substantially. Thus closure of cenosis resulted in a weakening of control over microbial development by Azolla. This tendency was augmented by spaceflight factors. Reduction in control exerted by macro-organisms over development of associated micro-organisms must be taken into account in constructing closed ecological systems in the state of weightlessness.
NASA Astrophysics Data System (ADS)
Koike, Hiroki; Ohsawa, Takashi; Miura, Sadahiko; Honjo, Hiroaki; Ikeda, Shoji; Hanyu, Takahiro; Ohno, Hideo; Endoh, Tetsuo
2015-04-01
A spintronic-based power-gated micro-processing unit (MPU) is proposed. It includes a power control circuit activated by the newly supported power-off instruction for the deep-sleep mode. These means enable the power-off procedure for the MPU to be executed appropriately. A test chip was designed and fabricated using 90 nm CMOS and an additional 100 nm MTJ process; it was successfully operated. The guideline of the energy reduction effects for this MPU was presented, using the estimation based on the measurement results of the test chip. The result shows that a large operation energy reduction of 1/28 can be achieved when the operation duty is 10%, under the condition of a sufficient number of idle clock cycles.
MEMS device for spacecraft thermal control applications
NASA Technical Reports Server (NTRS)
Swanson, Theordore D. (Inventor)
2003-01-01
A micro-electromechanical device that comprises miniaturized mechanical louvers, referred to as Micro Electro-Mechanical Systems (MEMS) louvers are employed to achieve a thermal control function for spacecraft and instruments. The MEMS louvers are another form of a variable emittance control coating and employ micro-electromechanical technology. In a function similar to traditional, macroscopic thermal louvers, the MEMS louvers of the present invention change the emissivity of a surface. With the MEMS louvers, as with the traditional macroscopic louvers, a mechanical vane or window is opened and closed to allow an alterable radiative view to space.
NASA Astrophysics Data System (ADS)
Aphanuphong, Sutha
This research investigates design and control of an active catheter for minimally invasive medical procedures. Microfabrication techniques are developed and several prototypes were constructed. The understanding and analysis results from each design iteration are utilized to improve the overall design and the performance of each revision. An innovative co-fabrication method is explored to simplify the fabrication process and also improve the quality, repeatability, and reliability of the active catheter. This co-fabrication method enables a unique compact integrated heater and sensor film to be directly constructed on a shape memory alloy (SMA) sheet and to be utilized as an outline mask to pattern a micro SMA actuator. There are two functions integrated in the sensor film: heat sources to actuate the micro SMA actuator and sensors to provide temperature and strain of the active catheter to closed-loop control algorithms. Three main aspects are explored in this dissertation: thermal dynamics in the MicroFlex (muF) film and its effect on the sensor capabilities; non-minimum phase behavior and its effect on control performance, and film micro fabrication design and its effect on thermal dynamics. The sensor film developed from this understanding is able to deliver excellent heating and sensing performance with a simple design.
Contamination Study of Micro Pulsed Plasma Thruster
2008-03-01
missions ranging from nano -satellites to large spacecrafts requiring precision placement1. As an unfortunate side effect, the exhaust plume induces...the electrodes9. The electrodes have often been arranged coaxially . The system consists of electrodes, capacitors as energy storage units, a spark...increasing interest in the so-called micro- and nano -satellites, which are highly maneuverable and have lower cost. These small satellites are aimed to
Shen, Xin; Javidi, Bahram
2018-03-01
We have developed a three-dimensional (3D) dynamic integral-imaging (InIm)-system-based optical see-through augmented reality display with enhanced depth range of a 3D augmented image. A focus-tunable lens is adopted in the 3D display unit to relay the elemental images with various positions to the micro lens array. Based on resolution priority integral imaging, multiple lenslet image planes are generated to enhance the depth range of the 3D image. The depth range is further increased by utilizing both the real and virtual 3D imaging fields. The 3D reconstructed image and the real-world scene are overlaid using an optical see-through display for augmented reality. The proposed system can significantly enhance the depth range of a 3D reconstructed image with high image quality in the micro InIm unit. This approach provides enhanced functionality for augmented information and adjusts the vergence-accommodation conflict of a traditional augmented reality display.
Breakthrough: micro-electronic photovoltaics
Okandan, Murat; Gupta, Vipin
2018-01-16
Sandia developed tiny glitter-sized photovoltaic (PV) cells that could revolutionize solar energy collection. The crystalline silicon micro-PV cells will be cheaper and have greater efficiencies than current PV collectors. Micro-PV cells require relatively little material to form well-controlled, highly efficient devices. Cell fabrication uses common microelectric and micro-electromechanical systems (MEMS) techniques.
Understanding Micro-Ramp Control for Shock Boundary Layer Interactions
2008-02-07
micro-ramps on a supersonic boundary layer at M=3.0 was investigated using monotone integrated Large Eddy Simulations (MILES) and Reynolds Averaged Navier... Supersonic boundary layer flow with micro-ramp and no shock wave 3.2 SBLI with no micro-ramp 3.3 SBLI with micro-ramp 3.4 Micro-ramp size and location IV . C...ramps on a supersonic boundary layer at M=3.0 was investigated using monotone integrated Large Eddy Simulations (MILES) and Reynolds Averaged Navier
Shao, Yue
2014-01-01
The rapid development of micro/nanoengineered functional biomaterials in the last two decades has empowered materials scientists and bioengineers to precisely control different aspects of the in vitro cell microenvironment. Following a philosophy of reductionism, many studies using synthetic functional biomaterials have revealed instructive roles of individual extracellular biophysical and biochemical cues in regulating cellular behaviors. Development of integrated micro/nanoengineered functional biomaterials to study complex and emergent biological phenomena has also thrived rapidly in recent years, revealing adaptive and integrated cellular behaviors closely relevant to human physiological and pathological conditions. Working at the interface between materials science and engineering, biology, and medicine, we are now at the beginning of a great exploration using micro/nanoengineered functional biomaterials for both fundamental biology study and clinical and biomedical applications such as regenerative medicine and drug screening. In this review, we present an overview of state of the art micro/nanoengineered functional biomaterials that can control precisely individual aspects of cell-microenvironment interactions and highlight them as well-controlled platforms for mechanistic studies of mechano-sensitive and -responsive cellular behaviors and integrative biology research. We also discuss the recent exciting trend where micro/nanoengineered biomaterials are integrated into miniaturized biological and biomimetic systems for dynamic multiparametric microenvironmental control of emergent and integrated cellular behaviors. The impact of integrated micro/nanoengineered functional biomaterials for future in vitro studies of regenerative medicine, cell biology, as well as human development and disease models are discussed. PMID:24339188
Chan, Emmanuel; Dalci, Oyku; Petocz, Peter; Papadopoulou, Alexandra K; Darendeliler, M Ali
2018-02-01
Studies have demonstrated the potential efficacy of micro-osteoperforations in accelerating tooth movement by amplifying the expression of inflammatory markers. The aim of this investigation was to examine the effects of micro-osteoperforations on orthodontic root resorption with microcomputed tomography. This prospective controlled clinical trial involved 20 subjects requiring extraction of the maxillary first premolars as part of their orthodontic treatment. A buccal tipping force of 150 g was applied to both premolars. Using the Propel appliance (Propel Orthodontics, San Jose, Calif), micro-osteoperforations were applied at a depth of 5 mm on the mesial and distal aspects in the midroot region of the experimental side of the first premolar root; the contralateral side served as the control. After 28 days, both premolars were extracted. The teeth were scanned under microcomputed tomography, and the volumes of root resorption craters were calculated and compared. Premolars treated with micro-osteoperforation exhibited significantly greater average total amounts of root resorption than did the control teeth (0.576 vs 0.406 mm 3 ). The total average volumetric root loss of premolars treated with micro-osteoperforation was 42% greater than that of the control teeth. This 28-day trial showed that micro-osteoperforations resulted in greater orthodontic root resorption. However, these results should be verified in patients who are undergoing full-length orthodontic treatment. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
Selmke, Markus; Khadka, Utsab; Bregulla, Andreas P; Cichos, Frank; Yang, Haw
2018-04-18
Photon nudging is a new experimental method which enables the force-free manipulation and localization of individual self-propelled artificial micro-swimmers in fluidic environments. It uses a weak laser to stochastically and adaptively turn on and off the swimmer's propulsion when the swimmer, through rotational diffusion, points towards or away from its target, respectively. This contribution presents a theoretical framework for the statistics of both 2D and 3D controls. The main results are: the on- and off-time distributions for the controlling laser, the arrival time statistics for the swimmer to reach a remote target, and how the experimentally accessible control parameters influence the control, e.g., the optimal acceptance angle for directed transport. The results are general in that they are independent of the propulsion or the actuation mechanisms. They provide a concrete physical picture for how a single artificial micro-swimmer could be navigated under thermal fluctuations-insights that could also be useful for understanding biological micro-swimmers.
Dehydration triggers differential microRNA expression in Xenopus laevis brain.
Luu, Bryan E; Storey, Kenneth B
2015-11-15
African clawed frogs, Xenopus laevis, although primarily aquatic, have a high tolerance for dehydration, being capable of withstanding the loss of up to 32-35% of total water body water. Recent studies have shown that microRNAs play a role in the response to dehydration by the liver, kidney and ventral skin of X. laevis. MicroRNAs act by modulating the expression of mRNA transcripts, thereby affecting diverse biochemical pathways. In this study, 43 microRNAs were assessed in frog brains comparing control and dehydrated (31.2±0.83% of total body water lost) conditions. MicroRNAs of interest were measured using a modified protocol which employs polyadenylation of microRNAs prior to reverse transcription and qPCR. Twelve microRNAs that showed a significant decrease in expression (to 41-77% of control levels) in brains from dehydrated frogs (xla-miR-15a, -150, -181a, -191, -211, -218, -219b, -30c, -30e, -31, -34a, and -34b) were identified. Genomic analysis showed that the sequences of these dehydration-responsive microRNAs were highly conserved as compared with the comparable microRNAs of mice (91-100%). Suppression of these microRNAs implies that translation of the mRNA transcripts under their control could be enhanced in response to dehydration. Bioinformatic analysis using the DIANA miRPath program (v.2.0) predicted the top two KEGG pathways that these microRNAs collectively regulate: 1. Axon guidance, and 2. Long-term potentiation. Previous studies indicated that suppression of these microRNAs promotes neuroprotective pathways by increasing the expression of brain-derived neurotrophic factor and activating anti-apoptotic pathways. This suggests that similar actions may be triggered in X. laevis brains as a protective response to dehydration. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.
Electronic eye occluder with time-counting and reflection control
NASA Astrophysics Data System (ADS)
Karitans, V.; Ozolinsh, M.; Kuprisha, G.
2008-09-01
In pediatric ophthalmology 2 - 3 % of all the children are impacted by a visual pathology - amblyopia. It develops if a clear image isn't presented to the retina during an early stage of the development of the visual system. A common way of treating this pathology is to cover the better-seeing eye to force the "lazy" eye to learn seeing. However, children are often reluctant to wear such an occluder because they are ashamed or simply because they find it inconvenient. This fact requires to find a way how to track the regime of occlusion because results of occlusion is a hint that the actual regime of occlusion isn't that what the optometrist has recommended. We design an electronic eye occluder that allows to track the regime of eye occlusion. We employ real-time clock DS1302 providing time information from seconds to years. Data is stored in the internal memory of the CPU (EEPROM). The MCU (PIC16F676) switches on only if a mechanical switch is closed and temperature has reached a satisfactory level. The occlusion is registered between time moments when the infrared signal appeared and disappeared.
NASA Astrophysics Data System (ADS)
Peng, Cong; Fan, Yahong; Huang, Ziyuan; Han, Bangcheng; Fang, Jiancheng
2017-01-01
This paper presents a novel synchronous micro-vibration suppression method on the basis of the small gain theorem to reduce the frequency-varying synchronous micro-vibration forces for a magnetically suspended flywheel (MSFW). The proposed synchronous micro-vibration suppression method not only eliminates the synchronous current fluctuations to force the rotor spinning around the inertia axis, but also considers the compensation caused by the displacement stiffness in the permanent-magnet (PM)-biased magnetic bearings. Moreover, the stability of the proposed control system is exactly analyzed by using small gain theorem. The effectiveness of the proposed micro-vibration suppression method is demonstrated via the direct measurement of the disturbance forces for a MSFW. The main merit of the proposed method is that it provides a simple and practical method in suppressing the frequency varying micro-vibration forces and preserving the nominal performance of the baseline control system.
A normally-closed piezoelectric micro-valve with flexible stopper
NASA Astrophysics Data System (ADS)
Chen, Song; Lu, Song; Liu, Yong; Wang, Jiantao; Tian, Xiaochao; Liu, Guojun; Yang, Zhigang
2016-04-01
In the field of controlled drug delivery system, there are still many problems on those reported micro-valves, such as the small opening height, unsatisfactory particle tolerance and high cost. To solve the above problems, a novel normally-closed piezoelectric micro-valve is presented in this paper. The micro-valve was driven by circular unimorph piezoelectric vibrator and natural rubber membrane with high elasticity was used as the valve stopper. The small axial displacement of piezoelectric vibrator can be converted into a large stroke of valve stopper based on hydraulic amplification mechanism. The experiment indicates that maximum hydraulic amplification ratio is up to 14, and the cut-off pressure of the micro-valve is 39kPa in the case of no working voltage. The presented micro valve has a large flow control range (ranging from 0 to 8.75mL/min).
MEMS deformable mirror for wavefront correction of large telescopes
NASA Astrophysics Data System (ADS)
Manhart, Sigmund; Vdovin, Gleb; Collings, Neil; Sodnik, Zoran; Nikolov, Susanne; Hupfer, Werner
2017-11-01
A 50 mm diameter membrane mirror was designed and manufactured at TU Delft. It is made from bulk silicon by micromachining - a technology primarily used for micro-electromechanical systems (MEMS). The mirror unit is equipped with 39 actuator electrodes and can be electrostatically deformed to correct wavefront errors in optical imaging systems. Performance tests on the deformable mirror were carried out at Astrium GmbH using a breadboard setup with a wavefront sensor and a closed-loop control system. It was found that the deformable membrane mirror is well suited for correction of low order wavefront errors as they must be expected in lightweighted space telescopes.
[Clinical effects of micro-implant and traditional anchorage in orthodontic treatments].
Qian, Yi; Zhou, Hua-Jie; Wu, Jian-Hua
2017-06-01
To analyze the value of micro-implant and traditional anchorage in the treatment of malocclusion. From Jan 2015 to Jan 2016, 20 cases with malocclusion were randomly divided into control group(10) and experimental group (10). A comparison was conducted between the control group, in which traditional anchorage was used and the experimental group, in which micro-implant anchorage was adopted. The data were analyzed with SPSS 17.0 software package. There was significant difference of U1-NA, L1-NB, U1-APg, U6-PtPNS between the 2 groups(P<0.05). Adverse reaction was not found in the control group, but 8% in the experimental group(P<0.05). Micro-implant anchorage can improve overjet relation of the anterior teeth and effect of orthodontic treatment.
NASA Technical Reports Server (NTRS)
Anderson, Bernhard H.; Keller, Dennis J.
2002-01-01
The purpose of this study on micro-scale secondary flow control (MSFC) is to study the aerodynamic behavior of micro-vane effectors through their factor (i.e., the design variable) interactions and to demonstrate how these statistical interactions, when brought together in an optimal manner, determine design robustness. The term micro-scale indicates the vane effectors are small in comparison to the local boundary layer height. Robustness in this situation means that it is possible to design fixed MSFC robust installation (i.e.. open loop) which operates well over the range of mission variables and is only marginally different from adaptive (i.e., closed loop) installation design, which would require a control system. The inherent robustness of MSFC micro-vane effector installation designs comes about because of their natural aerodynamic characteristics and the manner in which these characteristics are brought together in an optimal manner through a structured Response Surface Methodology design process.
NASA Astrophysics Data System (ADS)
Yang, Yang; Pan, Yayue; Guo, Ping
2017-04-01
Creating orderly periodic micro/nano-structures on metallic surfaces, or structural coloration, for control of surface apparent color and optical reflectivity has been an exciting research topic over the years. The direct applications of structural coloration include color marking, display devices, and invisibility cloak. This paper presents an efficient method to colorize metallic surfaces with periodic micro/nano-gratings using elliptical vibration texturing. When the tool vibration is coupled with a constant cutting velocity, controlled periodic ripples can be generated due to the overlapping tool trajectory. These periodic ripples with a wavelength near visible spectrum can act as micro-gratings to introduce iridescent colors. The proposed technique also provides a flexible method for color marking of metallic surfaces with arbitrary patterns and images by precise control of the spacing distance and orientation of induced micro/nano-ripples. Theoretical analysis and experimental results are given to demonstrate structural coloration of metals by a direct mechanical machining technique.
NASA Technical Reports Server (NTRS)
2001-01-01
Traditional spacecraft power systems incorporate a solar array energy source, an energy storage element (battery), and battery charge control and bus voltage regulation electronics to provide continuous electrical power for spacecraft systems and instruments. Dedicated power conditioning components provide limited fault isolation between systems and instruments, while a centralized power-switching unit provides spacecraft load control. Battery undervoltage conditions are detected by the spacecraft processor, which removes fault conditions and non-critical loads before permanent battery damage can occur. Cost effective operation of a micro-sat constellation requires a fault tolerant spacecraft architecture that minimizes on-orbit operational costs by permitting autonomous reconfiguration in response to unexpected fault conditions. A new micro-sat power system architecture that enhances spacecraft fault tolerance and improves power system survivability by continuously managing the battery charge and discharge processes on a cell-by-cell basis has been developed. This architecture is based on the Integrated Power Source (US patent 5644207), which integrates dual junction solar cells, Lithium Ion battery cells, and processor based charge control electronics into a structural panel that can be deployed or used to form a portion of the outer shell of a micro-spacecraft. The first generation Integrated Power Source is configured as a one inch thick panel in which prismatic Lithium Ion battery cells are arranged in a 3x7 matrix (26VDC) and a 3x1 matrix (3.7VDC) to provide the required output voltages and load currents. A multi-layer structure holds the battery cells, as well as the thermal insulators that are necessary to protect the Lithium Ion battery cells from the extreme temperatures of the solar cell layer. Independent thermal radiators, located on the back of the panel, are dedicated to the solar cell array, the electronics, and the battery cell array. In deployed panel applications, these radiators maintain the battery cells in an appropriate operational temperature range.
Lower neurocognitive function in U-2 pilots
Tate, David F.; Wood, Joe; Sladky, John H.; McDonald, Kent; Sherman, Paul M.; Kawano, Elaine S.; Rowland, Laura M.; Patel, Beenish; Wright, Susan N.; Hong, Elliot; Rasmussen, Jennifer; Willis, Adam M.; Kochunov, Peter V.
2014-01-01
Objective: Determine whether United States Air Force (USAF) U-2 pilots (U2Ps) with occupational exposure to repeated hypobaria had lower neurocognitive performance compared to pilots without repeated hypobaric exposure and whether U2P neurocognitive performance correlated with white matter hyperintensity (WMH) burden. Methods: We collected Multidimensional Aptitude Battery–II (MAB-II) and MicroCog: Assessment of Cognitive Functioning (MicroCog) neurocognitive data on USAF U2Ps with a history of repeated occupational exposure to hypobaria and compared these with control data collected from USAF pilots (AFPs) without repeated hypobaric exposure (U2Ps/AFPs MAB-II 87/83; MicroCog 93/80). Additional comparisons were performed between U2Ps with high vs low WMH burden. Results: U2Ps with repeated hypobaric exposure had significantly lower scores than control pilots on reasoning/calculation (U2Ps/AFPs 99.4/106.5), memory (105.5/110.9), information processing accuracy (102.1/105.8), and general cognitive functioning (103.5/108.5). In addition, U2Ps with high whole-brain WMH count showed significantly lower scores on reasoning/calculation (high/low 96.8/104.1), memory (102.9/110.2), general cognitive functioning (101.5/107.2), and general cognitive proficiency (103.6/108.8) than U2Ps with low WMH burden (high/low WMH mean volume 0.213/0.003 cm3 and mean count 14.2/0.4). Conclusion: In these otherwise healthy, highly functioning individuals, pilots with occupational exposure to repeated hypobaria demonstrated lower neurocognitive performance, albeit demonstrable on only some tests, than pilots without repeated exposure. Furthermore, within the U2P population, higher WMH burden was associated with lower neurocognitive test performance. Hypobaric exposure may be a risk factor for subtle changes in neurocognition. PMID:25008397
Wen, Zhi-yu; Chen, Gang; Wang, Jian-guo
2006-10-01
This paper advances a kind of micro-spectrometer based on Fabry-Perot cavity's character of filtering the waves. The basic structure of the micro-spectrometer is the array of Fabry-Perot cavity which contains many different lengths of cavity on the substrate of silicon, consequently the authors can achieve the detection at several wavelengths simultaneously. The unit of probing is a Fabry-Perot cavity made up of the substrate of silicon-metal film-silicon dioxide layer-metal film. The authors carried out the corresponding simulation. In the basic structure of aluminum film(14 nm)-silicon dioxide layer-silver film(39 nm), the resolution can reach 15 nm. When the area of a unit of probing is 0.14 mm x 0.14 mm only, it can reach the luminous flux of miniature grating spectrum instrument (the minimum volume in the order of cm), but the volume of the part of spectrum detection is only of the order of mm. The design size of the micro-spectrometer is a few millimeters. Furthermore it has no movable parts and could detect several wavelengths at the same time. It is possible to fabricate such micro-spectrometer through existing processing methods of IC technology.
Wang, Ying; Wang, D N; Liao, C R; Hu, Tianyi; Guo, Jiangtao; Wei, Huifeng
2013-02-01
A temperature-insensitive micro Fabry-Pérot (FP) cavity based on simplified hollow-core (SHC) photonic crystal fiber (PCF) is demonstrated. Such a device is fabricated by splicing a section of SHC PCF with single mode fibers at both cleaved ends. An extremely low temperature sensitivity of ~0.273 pm/°C is obtained between room temperature and 900°C. By drilling vertical micro-channels using a femtosecond laser, the micro FP cavity can be filled with liquids and functions as a sensitive refractometer and the refractive index sensitivity obtained is ~851.3 nm/RIU (refractive index unit), which indicates an ultra low temperature cross-sensitivity of ~3.2×10(-7) RIU/°C.
Study on improved Ip-iq APF control algorithm and its application in micro grid
NASA Astrophysics Data System (ADS)
Xie, Xifeng; Shi, Hua; Deng, Haiyingv
2018-01-01
In order to enhance the tracking velocity and accuracy of harmonic detection by ip-iq algorithm, a novel ip-iq control algorithm based on the Instantaneous reactive power theory is presented, the improved algorithm adds the lead correction link to adjust the zero point of the detection system, the Fuzzy Self-Tuning Adaptive PI control is introduced to dynamically adjust the DC-link Voltage, which meets the requirement of the harmonic compensation of the micro grid. Simulation and experimental results verify the proposed method is feasible and effective in micro grid.
A New Individually Addressable Micro-LED Array for Photogenetic Neural Stimulation.
McGovern, B; Berlinguer Palmini, R; Grossman, N; Drakakis, E; Poher, V; Neil, M A A; Degenaar, P
2010-12-01
Here, we demonstrate the use of a micro light emitting diode (LED) array as a powerful tool for complex spatiotemporal control of photosensitized neurons. The array can generate arbitrary, 2-D, excitation patterns with millisecond and micrometer resolution. In particular, we describe an active matrix control address system to allow simultaneous control of 256 individual micro LEDs. We present the system optically integrated into a microscope environment and patch clamp electrophysiology. The results show that the emitters have sufficient radiance at the required wavelength to stimulate neurons expressing channelrhodopsin-2 (ChR2).
Wikswo, J P; Prokop, A; Baudenbacher, F; Cliffel, D; Csukas, B; Velkovsky, M
2006-08-01
Systems biology, i.e. quantitative, postgenomic, postproteomic, dynamic, multiscale physiology, addresses in an integrative, quantitative manner the shockwave of genetic and proteomic information using computer models that may eventually have 10(6) dynamic variables with non-linear interactions. Historically, single biological measurements are made over minutes, suggesting the challenge of specifying 10(6) model parameters. Except for fluorescence and micro-electrode recordings, most cellular measurements have inadequate bandwidth to discern the time course of critical intracellular biochemical events. Micro-array expression profiles of thousands of genes cannot determine quantitative dynamic cellular signalling and metabolic variables. Major gaps must be bridged between the computational vision and experimental reality. The analysis of cellular signalling dynamics and control requires, first, micro- and nano-instruments that measure simultaneously multiple extracellular and intracellular variables with sufficient bandwidth; secondly, the ability to open existing internal control and signalling loops; thirdly, external BioMEMS micro-actuators that provide high bandwidth feedback and externally addressable intracellular nano-actuators; and, fourthly, real-time, closed-loop, single-cell control algorithms. The unravelling of the nested and coupled nature of cellular control loops requires simultaneous recording of multiple single-cell signatures. Externally controlled nano-actuators, needed to effect changes in the biochemical, mechanical and electrical environment both outside and inside the cell, will provide a major impetus for nanoscience.