Development of portable defocusing micro-scale spatially offset Raman spectroscopy.
Realini, Marco; Botteon, Alessandra; Conti, Claudia; Colombo, Chiara; Matousek, Pavel
2016-05-10
We present, for the first time, portable defocusing micro-Spatially Offset Raman Spectroscopy (micro-SORS). Micro-SORS is a concept permitting the analysis of thin, highly turbid stratified layers beyond the reach of conventional Raman microscopy. The technique is applicable to the analysis of painted layers in cultural heritage (panels, canvases and mural paintings, painted statues and decorated objects in general) as well as in many other areas including polymer, biological and biomedical applications, catalytic and forensics sciences where highly turbid stratified layers are present and where invasive analysis is undesirable or impossible. So far the technique has been demonstrated only on benchtop Raman microscopes precluding the non-invasive analysis of larger samples and samples in situ. The new set-up is characterised conceptually on a range of artificially assembled two-layer systems demonstrating its benefits and performance across several application areas. These included stratified polymer sample, pharmaceutical tablet and layered paint samples. The same samples were also analysed by a high performance (non-portable) benchtop Raman microscope to provide benchmarking against our earlier research. The realisation of the vision of delivering portability to micro-SORS has a transformative potential spanning across multiple disciplines as it fully unlocks, for the first time, the non-invasive and non-destructive aspects of micro-SORS enabling it to be applied also to large and non-portable samples in situ without recourse to removing samples, or their fragments, for laboratory analysis on benchtop Raman microscopes.
Analysis of Individual Cells and Endospores by Micro-Raman Spectroscopy
NASA Astrophysics Data System (ADS)
Esposito, Anthony; Huser, Thomas; Talley, Chad; Hollars, Christopher; Balhorn, Rod; Lane, Stephen
2003-03-01
We have collected Raman spectra of individual sperm cells by confocal micro-Raman spectroscopy. The high spatial resolution of this technique allows for compositional analysis of different sections of the sperm cells. The relative intensities of protein and DNA Raman transitions allow one to define a protein-DNA ratio. We have also collected the Raman spectra of individual bacterial endospores from four species in the genus Bacillus. The spectra were generally dominated by scattering from calcium dipicolinate, although scattering assignable to protein bands was also observed. A small fraction of the spores did not exhibit Raman scattering from CaDPA, possibly due to incomplete sporulation. These examples demonstrate the applicability of micro-Raman spectroscopy as a non-invasive method for addressing variability in the composition of cells.* *This work was performed under the auspices of the U.S. Department of Energy by the University of California, Lawrence Livermore National Laboratory under contract number W-7405-Eng-48.
Hahn, D W; Wolfarth, D L; Parks, N L
1997-04-01
This paper describes micro-Raman spectroscopy of ultra-high molecular weight polyethylene wear debris isolated from revised knee replacements. The novel application of micro-Raman spectroscopy to the analysis of in vivo-generated wear debris was used to evaluate the chemical nature of individual, retrieved polyethylene particles. The analysis revealed the presence of beta-carotene on particles from both synovial fluid and tissue samples. Raman analysis of retrieved polyethylene tibial inserts also revealed localized beta-carotene signals within the primary wear region. In this paper, a mechanism is suggested that may account for the coupling of beta-carotene and polyethylene wear debris. We also discuss the origin of beta-carotene within the implanted joint and the implications that beta-carotene, an anti-oxidant, has for the overall host response to polyethylene orthopedic components.
Kögler, Martin; Paul, Andrea; Anane, Emmanuel; Birkholz, Mario; Bunker, Alex; Viitala, Tapani; Maiwald, Michael; Junne, Stefan; Neubauer, Peter
2018-06-08
The application of Raman spectroscopy as a monitoring technique for bioprocesses is severely limited by a large background signal originating from fluorescing compounds in the culture media. Here we compare time-gated Raman (TG-Raman)-, continuous wave NIR-process Raman (NIR-Raman) and continuous wave micro-Raman (micro-Raman) approaches in combination with surface enhanced Raman spectroscopy (SERS) for their potential to overcome this limit. For that purpose, we monitored metabolite concentrations of Escherichia coli bioreactor cultivations in cell-free supernatant samples. We investigated concentration transients of glucose, acetate, AMP and cAMP at alternating substrate availability, from deficiency to excess. Raman and SERS signals were compared to off-line metabolite analysis of carbohydrates, carboxylic acids and nucleotides. Results demonstrate that SERS, in almost all cases, led to a higher number of identifiable signals and better resolved spectra. Spectra derived from the TG-Raman were comparable to those of micro-Raman resulting in well-discernable Raman peaks, which allowed for the identification of a higher number of compounds. In contrast, NIR-Raman provided a superior performance for the quantitative evaluation of analytes, both with and without SERS nanoparticles when using multivariate data analysis. This article is protected by copyright. All rights reserved. © 2018 American Institute of Chemical Engineers.
Vibrational Micro-Spectroscopy of Human Tissues Analysis: Review.
Bunaciu, Andrei A; Hoang, Vu Dang; Aboul-Enein, Hassan Y
2017-05-04
Vibrational spectroscopy (Infrared (IR) and Raman) and, in particular, micro-spectroscopy and micro-spectroscopic imaging have been used to characterize developmental changes in tissues, to monitor these changes in cell cultures and to detect disease and drug-induced modifications. The conventional methods for biochemical and histophatological tissue characterization necessitate complex and "time-consuming" sample manipulations and the results are rarely quantifiable. The spectroscopy of molecular vibrations using mid-IR or Raman techniques has been applied to samples of human tissue. This article reviews the application of these vibrational spectroscopic techniques for analysis of biological tissue published between 2005 and 2015.
Micro-Raman Analysis of Irradiated Diamond Films
NASA Technical Reports Server (NTRS)
Newton, R. L.; Munafo, Paul M. (Technical Monitor)
2002-01-01
Owing to its unique and robust physical properties, diamond is a much sought after material for use in advanced technologies such as Microelectromechanical Systems (MEMS). The volume and weight savings promised by MEMS-based devices are of particular interest to spaceflight applications. However, much basic materials science research remains to be completed in this field. Results of micro-Raman analysis of proton (1015 - 1017 H+/cm2 doses) irradiated chemical vapor deposited (CVD) diamond reveals that the microstructure is retained even after high radiation exposure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lines, Amanda M.; Nelson, Gilbert L.; Casella, Amanda J.
Microfluidic devices are a growing field with significant potential for application to small scale processing of solutions. Much like large scale processing, fast, reliable, and cost effective means of monitoring the streams during processing are needed. Here we apply a novel Micro-Raman probe to the on-line monitoring of streams within a microfluidic device. For either macro or micro scale process monitoring via spectroscopic response, there is the danger of interfering or confounded bands obfuscating results. By utilizing chemometric analysis, a form of multivariate analysis, species can be accurately quantified in solution despite the presence of overlapping or confounded spectroscopic bands.more » This is demonstrated on solutions of HNO 3 and NaNO 3 within micro-flow and microfluidic devices.« less
Wavelet data analysis of micro-Raman spectra for follow-up monitoring in oral pathologies
NASA Astrophysics Data System (ADS)
Camerlingo, C.; Zenone, F.; Perna, G.; Capozzi, V.; Cirillo, N.; Gaeta, G. M.; Lepore, M.
2008-02-01
A wavelet multi-component decomposition algorithm has been used for data analysis of micro-Raman spectra from human biological samples. In particular, measurements have been performed on some samples of oral tissue and blood serum from patients affected by pemphigus vulgaris at different stages. Pemphigus is a chronic, autoimmune, blistering disease of the skin and mucous membranes with a potentially fatal outcome. The disease is characterized histologically by intradermal blisters and immunopathologically by the finding of tissue bound and circulating immunoglobulin G (IgG) antibody directed against the cell surface of keratinocytes. More than 150 spectra were measured by means of a Raman confocal microspectrometer apparatus using the 632.8 nm line of a He-Ne laser source. A discrete wavelet transform decomposition method has been applied to the recorded Raman spectra in order to overcome related to low-level signals and the presence of noise and background components due to light scattering and fluorescence. The results indicate that appropriate data processing can contribute to enlarge the medical applications of micro-Raman spectroscopy.
Micro-Raman Analysis of Irradiated Diamond Films
NASA Technical Reports Server (NTRS)
Newton, Robert L.
2003-01-01
Owing to its unique and robust physical properties, diamond is a much sought after material for use in advanced technologies, even in Microelectromechanical Systems (MEMS). The volume and weight savings promised by MEMS-based devices are of particular interest to spaceflight applications. However, much basic materials science research remains to be completed in this field. Results of micro-Raman analysis of proton (10(exp 15) - 10(exp 17) H(+)/sq cm doses) irradiated chemical vapor deposited (CVD) films are presented and indicate that their microstructure is retained even after high radiation exposure.
Micro-mirror arrays for Raman spectroscopy
NASA Astrophysics Data System (ADS)
Duncan, W. M.
2015-03-01
In this research we study Raman and fluorescence spectroscopies as non-destructive and noninvasive methods for probing biological material and "living systems." Particularly for a living material any probe need be non-destructive and non-invasive, as well as provide real time measurement information and be cost effective to be generally useful. Over the past few years the components needed to measure weak and complex processes such as Raman scattering have evolved substantially with the ready availability of lasers, dichroic filters, low noise and sensitive detectors, digitizers and signal processors. A Raman spectrum consists of a wavelength or frequency spectrum that corresponds to the inelastic (Raman) photon signal that results from irradiating a "Raman active" material. Raman irradiation of a material usually and generally uses a single frequency laser. The Raman fingerprint spectrum that results from a Raman interaction can be determined from the frequencies scattered and received by an appropriate detector. Spectra are usually "digitized" and numerically matched to a reference sample or reference material spectra in performing an analysis. Fortunately today with the many "commercial off-the-shelf" components that are available, weak intensity effects such as Raman and fluorescence spectroscopy can be used for a number of analysis applications. One of the experimental limitations in Raman measurement is the spectrometer itself. The spectrometer is the section of the system that either by interference plus detection or by dispersion plus detection that "signal" amplitude versus energy/frequency signals are measured. Particularly in Raman spectroscopy, optical signals carrying desired "information" about the analyte are extraordinarily weak and require special considerations when measuring. We will discuss here the use of compact spectrometers and a micro-mirror array system (used is the digital micro-mirror device (DMD) supplied by the DLP® Products group of Texas Instruments Incorporated) for analyzing dispersed light as needed in Raman and fluorescent applications.
Raman-spectroscopy-based biosensing for applications in ophthalmology
NASA Astrophysics Data System (ADS)
Rusciano, Giulia; Capriglione, Paola; Pesce, Giuseppe; Zito, Gianluigi; Del Prete, Antonio; Cennamo, Giovanni; Sasso, Antonio
2013-05-01
Cell-based biosensors rely on the detection and identification of single cells as well as monitoring of changes induced by interaction with drugs and/or toxic agents. Raman spectroscopy is a powerful tool to reach this goal, being non-destructive analytical technique, allowing also measurements of samples in aqueous environment. In addition, micro-Raman measurements do not require preliminary sample preparation (as in fluorescence spectroscopy), show a finger-print spectral response, allow a spatial resolution below typical cell sizes, and are relatively fast (few s or even less). All these properties make micro-Raman technique particularly promising for high-throughput on-line analysis integrated in lab-on-a-chip devices. Herein, we demonstrate some applications of Raman analysis in ophthalmology. In particular, we demonstrate that Raman analysis can provide useful information for the therapeutic treatment of keratitis caused by Acanthamoeba Castellanii (A.), an opportunistic protozoan that is widely distributed in the environment and is known to produce blinding keratitis and fatal encephalitis. In particular, by combining Raman analysis with Principal Component Analysis (PCA), we have demonstrated that is possible to distinguish between live and dead cells, enabling, therefore to establish the effectiveness of therapeutic strategies to vanquish the protozoa. As final step, we have analyzed the presence of biochemical differences in the conjunctival epithelial tissues of patients affected by keratitis with respect to healthy people. As a matter of facts, it is possible to speculate some biochemical alterations of the epithelial tissues, rendering more favorable the binding of the protozoan. The epithelial cells were obtained by impression cytology from eyes of both healthy and keratitis-affected individuals. All the samples were analyzed by Raman spectroscopy within a few hours from cells removal from eyes. The results of this analysis are discussed.
Applications of Raman spectroscopy in life science
NASA Astrophysics Data System (ADS)
Martin, Airton A.; T. Soto, Cláudio A.; Ali, Syed M.; Neto, Lázaro P. M.; Canevari, Renata A.; Pereira, Liliane; Fávero, Priscila P.
2015-06-01
Raman spectroscopy has been applied to the analysis of biological samples for the last 12 years providing detection of changes occurring at the molecular level during the pathological transformation of the tissue. The potential use of this technology in cancer diagnosis has shown encouraging results for the in vivo, real-time and minimally invasive diagnosis. Confocal Raman technics has also been successfully applied in the analysis of skin aging process providing new insights in this field. In this paper it is presented the latest biomedical applications of Raman spectroscopy in our laboratory. It is shown that Raman spectroscopy (RS) has been used for biochemical and molecular characterization of thyroid tissue by micro-Raman spectroscopy and gene expression analysis. This study aimed to improve the discrimination between different thyroid pathologies by Raman analysis. A total of 35 thyroid tissues samples including normal tissue (n=10), goiter (n=10), papillary (n=10) and follicular carcinomas (n=5) were analyzed. The confocal Raman spectroscopy allowed a maximum discrimination of 91.1% between normal and tumor tissues, 84.8% between benign and malignant pathologies and 84.6% among carcinomas analyzed. It will be also report the application of in vivo confocal Raman spectroscopy as an important sensor for detecting advanced glycation products (AGEs) on human skin.
Camerlingo, Carlo; Zenone, Flora; Perna, Giuseppe; Capozzi, Vito; Cirillo, Nicola; Gaeta, Giovanni Maria; Lepore, Maria
2008-06-01
A wavelet multi-component decomposition algorithm has been used for data analysis of micro-Raman spectra of blood serum samples from patients affected by pemphigus vulgaris at different stages. Pemphigus is a chronic, autoimmune, blistering disease of the skin and mucous membranes with a potentially fatal outcome. Spectra were measured by means of a Raman confocal microspectrometer apparatus using the 632.8 nm line of a He-Ne laser source. A discrete wavelet transform decomposition method has been applied to the recorded Raman spectra in order to overcome problems related to low-level signals and the presence of noise and background components due to light scattering and fluorescence. This numerical data treatment can automatically extract quantitative information from the Raman spectra and makes more reliable the data comparison. Even if an exhaustive investigation has not been done in this work, the feasibility of the follow-up monitoring of pemphigus vulgaris pathology has been clearly proved with useful implications for the clinical applications.
Camerlingo, Carlo; Zenone, Flora; Perna, Giuseppe; Capozzi, Vito; Cirillo, Nicola; Gaeta, Giovanni Maria; Lepore, Maria
2008-01-01
A wavelet multi-component decomposition algorithm has been used for data analysis of micro-Raman spectra of blood serum samples from patients affected by pemphigus vulgaris at different stages. Pemphigus is a chronic, autoimmune, blistering disease of the skin and mucous membranes with a potentially fatal outcome. Spectra were measured by means of a Raman confocal microspectrometer apparatus using the 632.8 nm line of a He-Ne laser source. A discrete wavelet transform decomposition method has been applied to the recorded Raman spectra in order to overcome problems related to low-level signals and the presence of noise and background components due to light scattering and fluorescence. This numerical data treatment can automatically extract quantitative information from the Raman spectra and makes more reliable the data comparison. Even if an exhaustive investigation has not been done in this work, the feasibility of the follow-up monitoring of pemphigus vulgaris pathology has been clearly proved with useful implications for the clinical applications. PMID:27879899
NASA Astrophysics Data System (ADS)
Chen, Long; Wang, Yue; Liu, Nenrong; Lin, Duo; Weng, Cuncheng; Zhang, Jixue; Zhu, Lihuan; Chen, Weisheng; Chen, Rong; Feng, Shangyuan
2013-06-01
The diagnostic capability of using tissue intrinsic micro-Raman signals to obtain biochemical information from human esophageal tissue is presented in this paper. Near-infrared micro-Raman spectroscopy combined with multivariate analysis was applied for discrimination of esophageal cancer tissue from normal tissue samples. Micro-Raman spectroscopy measurements were performed on 54 esophageal cancer tissues and 55 normal tissues in the 400-1750 cm-1 range. The mean Raman spectra showed significant differences between the two groups. Tentative assignments of the Raman bands in the measured tissue spectra suggested some changes in protein structure, a decrease in the relative amount of lactose, and increases in the percentages of tryptophan, collagen and phenylalanine content in esophageal cancer tissue as compared to those of a normal subject. The diagnostic algorithms based on principal component analysis (PCA) and linear discriminate analysis (LDA) achieved a diagnostic sensitivity of 87.0% and specificity of 70.9% for separating cancer from normal esophageal tissue samples. The result demonstrated that near-infrared micro-Raman spectroscopy combined with PCA-LDA analysis could be an effective and sensitive tool for identification of esophageal cancer.
Application of micro-Raman spectroscopy for fight against terrorism and smuggling
NASA Astrophysics Data System (ADS)
Almaviva, Salvatore; Botti, Sabina; Palucci, Antonio; Puiu, Adriana; Schnürer, Frank; Schweikert, Wenka; Romolo, Francesco Saverio
2014-04-01
We report the results of Raman measurements on some common military explosives and explosives precursors deposited on clothing fabrics, both synthetic and natural, in concentration comparable to those obtained from a single fingerprint or mixed with similar harmless substances to detect illegal compounds for smuggling activities. Raman spectra were obtained using an integrated portable Raman system equipped with an optical microscope and a 785-nm laser in an analysis of <1 min. The spectral features of each illicit substance have been identified and distinguished from those belonging to the substrate fabric or from the interfering compound. Our results show that the application of Raman spectroscopy (RS) with a microscope-based portable apparatus can provide interpretable Raman spectra for a fast, in-situ analysis, directly from explosive particles of some μ, despite the contribution of the substrate, leaving the sample completely unaltered for further, more specific, and propedeutic laboratory analysis. We also show how the RS is suitable for detecting illegal compounds mixed with harmless substances for smuggling purposes or for counterfeiting activities.
NASA Astrophysics Data System (ADS)
Conti, Claudia; Realini, Marco; Colombo, Chiara; Botteon, Alessandra; Bertasa, Moira; Striova, Jana; Barucci, Marco; Matousek, Pavel
2016-12-01
We present a method for estimating the thickness of thin turbid layers using defocusing micro-spatially offset Raman spectroscopy (micro-SORS). The approach, applicable to highly turbid systems, enables one to predict depths in excess of those accessible with conventional Raman microscopy. The technique can be used, for example, to establish the paint layer thickness on cultural heritage objects, such as panel canvases, mural paintings, painted statues and decorated objects. Other applications include analysis in polymer, biological and biomedical disciplines, catalytic and forensics sciences where highly turbid overlayers are often present and where invasive probing may not be possible or is undesirable. The method comprises two stages: (i) a calibration step for training the method on a well characterized sample set with a known thickness, and (ii) a prediction step where the prediction of layer thickness is carried out non-invasively on samples of unknown thickness of the same chemical and physical make up as the calibration set. An illustrative example of a practical deployment of this method is the analysis of larger areas of paintings. In this case, first, a calibration would be performed on a fragment of painting of a known thickness (e.g. derived from cross-sectional analysis) and subsequently the analysis of thickness across larger areas of painting could then be carried out non-invasively. The performance of the method is compared with that of the more established optical coherence tomography (OCT) technique on identical sample set. This article is part of the themed issue "Raman spectroscopy in art and archaeology".
New insight into UO 2F 2 particulate structure by micro-Raman spectroscopy
Stefaniak, Elzbieta A.; Darchuk, Larysa; Sapundjiev, Danislav; ...
2013-02-19
Uranyl fluoride particles produced via hydrolysis of uranium hexafluoride have been deposited on different substrates: polished graphite disks, silver foil, stainless steel and gold-coated silicon wafer, and measured with micro-Raman spectroscopy (MRS). All three metallic substrates enhanced the Raman signal delivered by UO 2F 2 in comparison to graphite. The fundamental stretching of the U–O band appeared at 867 cm –1 in case of the graphite substrate, while in case of the others it was shifted to lower frequencies (down to 839 cm –1). All applied metallic substrates showed the expected effect of Raman signal enhancement; however the gold layermore » appeared to be most effective. Lastly, application of new substrates provides more information on the molecular structure of uranyl fluoride precipitation, which is interesting for nuclear safeguards and nuclear environmental analysis.« less
Lenz, Robin; Enders, Kristina; Stedmon, Colin A; Mackenzie, David M A; Nielsen, Torkel Gissel
2015-11-15
Identification and characterisation of microplastic (MP) is a necessary step to evaluate their concentrations, chemical composition and interactions with biota. MP ≥10μm diameter filtered from below the sea surface in the European and subtropical North Atlantic were simultaneously identified by visual microscopy and Raman micro-spectroscopy. Visually identified particles below 100μm had a significantly lower percentage confirmed by Raman than larger ones indicating that visual identification alone is inappropriate for studies on small microplastics. Sixty-eight percent of visually counted MP (n=1279) were spectroscopically confirmed being plastic. The percentage varied with type, colour and size of the MP. Fibres had a higher success rate (75%) than particles (64%). We tested Raman micro-spectroscopy applicability for MP identification with respect to varying chemical composition (additives), degradation state and organic matter coating. Partially UV-degraded post-consumer plastics provided identifiable Raman spectra for polymers most common among marine MP, i.e. polyethylene and polypropylene. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Schechinger, Monika; Marks, Haley; Locke, Andrea; Choudhury, Mahua; Coté, Gerard
2017-02-01
Human biomarkers are indicative of the body's relative state prior to the onset of disease, and sometimes before symptoms present. While blood biomarker detection has achieved considerable success in laboratory settings, its clinical application is lagging and commercial point-of-care devices are rare. A physician's ability to detect biomarkers such as microRNA-17, a potential epigenetic indicator of preeclampsia in pregnant woman, could enable early diagnosis and preventive intervention as early as the 1st trimester. One detection approach employing DNA-functionalized nanoparticles to detect microRNA-17, in conjunction with surface-enhanced Raman spectroscopy (SERS), has shown promise but is hindered, in part, by the use of large and expensive benchtop Raman microscopes. However, recent strides have been made in developing portable Raman systems for field applications. Characteristics of the SERS assay responsible for strengthening the assay's plasmonic response were explored, whilst comparing the results from both benchtop and portable Raman systems. The Raman spectra and intensity of three different types of photoactive molecules were compared as potential Raman reporter molecules: chromophores, fluorophores, and highly polarizable small molecules. Furthermore, the plasmonic characteristics governing the formation of SERS colloidal nanoparticle assemblies in response to DNA/miRNA hybridization were investigated. There were significant variations in the SERS enhancement in response to microRNA-17 using our assay depending on the excitation lasers at wavelengths of 532 nm and 785 nm, depending on which of the three different Raman systems were used (benchtop, portable, and handheld), and depending on which of the three different Raman reporters (chromophore, fluorophore, or Raman active molecule) were used. Analysis of data obtained did indicate that signal enhancement was better for the chromophore (MGITC) and Raman active molecule (DTNB) than it was for the fluorophore (TRITC) and that, although it is possible to obtain enhancements when using excitation lasers that do not directly coincide with the optical properties of the Raman reporter molecule, clearly the enhancements are more significant when it reaches to the characteristic wavelengths of those molecules.
You, Sixian; Tu, Haohua; Zhao, Youbo; Liu, Yuan; Chaney, Eric J; Marjanovic, Marina; Boppart, Stephen A
2016-09-06
Fatty acids play essential roles in the growth and metastasis of cancer cells. To facilitate their avid growth and proliferation, cancer cells not only alter the fatty acid synthesis and metabolism intracellularly and extracellularly, but also in the macroenvironment via direct or indirect pathways. We report here, using Raman micro-spectroscopy, that an increase in the production of polyunsaturated fatty acids (PUFAs) was identified in both cancerous and normal appearing breast tissue obtained from breast cancer patients and tumor-bearing rats. By minimizing confounding effects from mixed chemicals and optimizing the signal-to-noise ratio of Raman spectra, we observed a large-scale transition from monounsaturated fatty acids to PUFAs in the tumor while only a small subset of fatty acids transitioned to PUFAs in the tumor micro- and macroenvironment. These data have important implications for further clarifying the macroenvironmental effect of cancer progression and provide new potential approaches for characterizing the tumor micro- and macroenvironment of breast cancer in both pre-clinical animal studies and clinical applications.
You, Sixian; Tu, Haohua; Zhao, Youbo; Liu, Yuan; Chaney, Eric J.; Marjanovic, Marina; Boppart, Stephen A.
2016-01-01
Fatty acids play essential roles in the growth and metastasis of cancer cells. To facilitate their avid growth and proliferation, cancer cells not only alter the fatty acid synthesis and metabolism intracellularly and extracellularly, but also in the macroenvironment via direct or indirect pathways. We report here, using Raman micro-spectroscopy, that an increase in the production of polyunsaturated fatty acids (PUFAs) was identified in both cancerous and normal appearing breast tissue obtained from breast cancer patients and tumor-bearing rats. By minimizing confounding effects from mixed chemicals and optimizing the signal-to-noise ratio of Raman spectra, we observed a large-scale transition from monounsaturated fatty acids to PUFAs in the tumor while only a small subset of fatty acids transitioned to PUFAs in the tumor micro- and macroenvironment. These data have important implications for further clarifying the macroenvironmental effect of cancer progression and provide new potential approaches for characterizing the tumor micro- and macroenvironment of breast cancer in both pre-clinical animal studies and clinical applications. PMID:27596041
Micro-Raman spectroscopy: The analysis of micrometer and submicrometer atmospheric aerosols
NASA Technical Reports Server (NTRS)
Klainer, S. M.; Milanovich, F. P.
1985-01-01
A nondestructive method of molecular analysis which is required to fully utilize the information contained within a collected particle is discussed. Upper atmosphere reaction mechanisms are assessed when the chemical compounds, the use of micro-Raman spectrometric techniques to perform micron and submicron particle analysis was evaluated. The results are favorable and it is concluded that micron and submicron particles can be analyzed by the micron-Raman approach. Completely automatic analysis should be possible to 0.3 micro m. No problems are anticipated with photo or thermal decomposition. Sample and impurity fluorescence are the key source of background as they cannot be completely eliminated.
Raman and Conductivity Analysis of Graphene for Biomedical Applications
Qiu, Chao; Bennet, Kevin E.; Khan, Tamanna; Ciubuc, John D.; Manciu, Felicia S.
2016-01-01
In this study, we present a comprehensive investigation of graphene’s optical and conductive properties using confocal Raman and a Drude model. A comparative analysis between experimental findings and theoretical predictions of the material’s changes and improvements as it transitioned from three-dimensional graphite is also presented and discussed. Besides spectral recording by Raman, which reveals whether there is a single, a few, or multi-layers of graphene, the confocal Raman mapping allows for distinction of such domains and a direct visualization of material inhomogeneity. Drude model employment in the analysis of the far-infrared transmittance measurements demonstrates a distinct increase of the material’s conductivity with dimensionality reduction. Other particularly important material characteristics, including carrier concentration and time constant, were also determined using this model and presented here. Furthermore, the detection of micromolar concentration of dopamine on graphene surfaces not only proves that the Raman technique facilitates ultrasensitive chemical detection of analytes, besides offering high information content about the biomaterial under study, but also that carbon-based materials are biocompatible and favorable micro-environments for such detection. Such information is valuable for the development of bio-medical sensors, which is the main application envisioned for this analysis. PMID:28774016
Biomedical Applications of Micro-Raman and Surface-Enhanced Raman Scattering (SERS) Technology
2012-10-01
to be an effective media for PSA capture. For SERS-based immunoassays, nitrocellulose offers comparable results to those obtained using gold-coated...glass substrates while offering a more cost- effective and time-saving method of detecting minute amounts of PSA; (ii) Micro-Raman imaging...technology was found to be effective in chemical mapping of arteries in the tissues of a post mortem individual whose cause of death was a cardiac event
Raman tweezers in microfluidic systems for analysis and sorting of living cells
NASA Astrophysics Data System (ADS)
Pilát, Zdeněk.; Ježek, Jan; Kaňka, Jan; Zemánek, Pavel
2014-12-01
We have devised an analytical and sorting system combining optical trapping with Raman spectroscopy in microfluidic environment, dedicated to identification and sorting of biological objects, such as living cells of various unicellular organisms. Our main goal was to create a robust and universal platform for non-destructive and non-contact sorting of micro-objects based on their Raman spectral properties. This approach allowed us to collect spectra containing information about the chemical composition of the objects, such as the presence and composition of pigments, lipids, proteins, or nucleic acids, avoiding artificial chemical probes such as fluorescent markers. The non-destructive nature of this optical analysis and manipulation allowed us to separate individual living cells of our interest in a sterile environment and provided the possibility to cultivate the selected cells for further experiments. We used a mixture of polystyrene micro-particles and algal cells to test and demonstrate the function of our analytical and sorting system. The devised system could find its use in many medical, biotechnological, and biological applications.
Quantitative micro-Raman analysis of volcanic glasses: influence and correction of matrix effects
NASA Astrophysics Data System (ADS)
Di Muro, Andrea
2014-05-01
Micro-Raman spectroscopy, even though a very promising micro-analytical technique, is still not used to routinely quantify volatile elements dissolved in glasses. Following an original idea of Galeener and Mikkelsen (1981) for the quantification of hydroxyl (OH) in silica glass, several quantitative procedures have been recently proposed for the analysis of water, sulphur and carbon in natural glasses (obsidians, pumices, melt inclusions). The quantification of a single analyte requires the calibration of the correlation between the intensity I (height or area) of the related Raman band, normalized or not to a reference band RB, and the analyte concentration. For the analysis of alumino-silicate glasses, RB corresponds to one of the two main envelopes (LF and HF) related to the vibration of the glass network. Calibrations are linear, provided the increase in the analyte concentration does not dramatically affect RB intensity. Much attention has been paid to identify the most appropriate spectral treatment (spectra reduction; baseline subtraction; etc) to achieve accurate measurement of band intensities. I here show that the accuracy of Raman procedures for volatile quantification critically depends on the capability in predicting and in taking into account the influence of multiple matrix effects, which are often correlated with the average polymerization degree of the glass network. A general model has been developed to predict matrix effects affecting micro-Raman analysis of natural glasses. The specific and critical influence of iron redox state and pressure are discussed. The approach has been extensively validated for the study of melt inclusions and matrices spanning a broad range of compositions and dissolved volatile contents. References Analytical procedures Mercier, M, Di Muro, A., Métrich, N., Giordano, D., Belhadj, O., Mandeville, C.W. (2010) Spectroscopic analysis (FTIR, Raman) of water in mafic and intermediate glasses and glass inclusions. Geochimica et Cosmochimica Acta, 74, 5641-5656. Mercier, M., Di Muro, A., Giordano, D., Métrich, N.,Pichavant, M., Clocchiatti, R., Montagnac, G. (2009) The influence of glass polymerization and oxidation on micro-Raman water analysis in alumino-silicate glasses. Geochimica et Cosmochimica Acta, 73, 197-217 Di Muro, A., Métrich, N., Mercier, M., Giordano, D., Massare, D., Montagnac, G. (2009) Micro-Raman determination of iron redox state in dry natural glasses : application to peralkaline rhyolites and basalts. Chemical Geology (Special volume on experimental techniques for the study of hydrothermal fluids and silicate melts) 259:78-88. Di Muro A, Villemant B, Montagnac G, Scaillet B, Reynard B (2006) The influence of glass composition on the determination of water content and speciation by Raman spectrometry. Geochimica and Cosmochimica Acta, 70, 2868-2884 Di Muro A, Giordano D., Villemant B, Montagnac G, Romano C. (2006) Influence of composition and thermal history of volcanic glasses on water content determination by microRaman spectrometry. Applied Geochemistry (Special volume on developments in analytical geochemistry). 21, 802-812. Application Di Muro, A., Staudacher, T., Ferrazzini, V., Villemant, B., Besson, P., Garofalo, C. (2014) Tracking magma injection in the Piton de la Fournaise volcanic edifice after the 2007 Summit Caldera Collapse by Pele's Hair Composition. Chapman Special Volume on Hawaiian volcanoes, AGU Books. Ardia, P., Di Muro, A., Giordano, D., Massare, D., Sanchez-Valle, C., Schmidt, M.W. (2014) Densification mechanisms of haplogranite glasses as a function of water content and pressure based on density and Raman data. Under review, submitted to Geochimica et Cosmochimica Acta. Métrich, N, Allard, P., Aiuppa, A., Bani, P., Bertagnini, A., Belhadj, O., Di Muro, A., Garaebiti, E., Massare, D., Parello, F., Shinohara, H. (2011) Magma and volatile feeding of post-caldera Yasur volcanism and block resurgence in Tanna island (Vanuatu arc). Journal of Petrology, 52(6): 1077-1105. Williamson, B.J., Di Muro, A., Horwell, C.J., Spieler, O., Llewellin (2010) Injection of vesicular magma into an andesitic dome at the effusive-explosive transition. Earth and Planetary Science Letters, 295, 83-90. Metrich, N., Bertagnini, A., Di Muro, A. (2010) Conditions of magma storage, degassing and ascent at Stromboli : new insights into the volcano plumbing system with inferences on the eruptive dynamics. Journal of Petrology, 51, 603-6026. Arias A., Oddone M., Bigazzi G., Di Muro A., Principe C., Norelli P. (2006) New data for the characterisation of Milos obsidians. Journal of Radioanalytical and Nuclear Chemistry, 268, 371-386.
Buzzini, Patrick; Massonnet, Genevieve
2015-05-01
In the second part of this survey, the ability of micro-Raman spectroscopy to discriminate 180 fiber samples of blue, black, and red cottons, wools, and acrylics was compared to that gathered with the traditional methods for the examination of textile fibers in a forensic context (including light microscopy methods, UV-vis microspectrophotometry and thin-layer chromatography). This study shows that the Raman technique plays a complementary and useful role to obtain further discriminations after the application of light microscopy methods and UV-vis microspectrophotometry and assure the nondestructive nature of the analytical sequence. These additional discriminations were observed despite the lower discriminating powers of Raman data considered individually, compared to those of light microscopy and UV-vis MSP. This study also confirms that an instrument equipped with several laser lines is necessary for an efficient use as applied to the examination of textile fibers in a forensic setting. © 2015 American Academy of Forensic Sciences.
Infrared and NIR Raman spectroscopy in medical microbiology
NASA Astrophysics Data System (ADS)
Naumann, Dieter
1998-04-01
FTIR and FT-NIR Raman spectra of intact microbial cells are highly specific, fingerprint-like signatures which can be used to (i) discriminate between diverse microbial species and strains, (ii) detect in situ intracellular components or structures such as inclusion bodies, storage materials or endospores, (iii) detect and quantify metabolically released CO2 in response to various different substrate, and (iv) characterize growth-dependent phenomena and cell-drug interactions. The characteristic information is extracted from the spectral contours by applying resolution enhancement techniques, difference spectroscopy, and pattern recognition methods such as factor-, cluster-, linear discriminant analysis, and artificial neural networks. Particularly interesting applications arise by means of a light microscope coupled to the spectrometer. FTIR spectra of micro-colonies containing less than 103 cells can be obtained from colony replica by a stamping technique that transfers micro-colonies growing on culture plates to a special IR-sample holder. Using a computer controlled x, y- stage together with mapping and video techniques, the fundamental tasks of microbiological analysis, namely detection, enumeration, and differentiation of micro- organisms can be integrated in one single apparatus. FTIR and NIR-FT-Raman spectroscopy can also be used in tandem to characterize medically important microorganisms. Currently novel methodologies are tested to take advantage of the complementary information of IR and Raman spectra. Representative examples on medically important microorganisms will be given that highlight the new possibilities of vibrational spectroscopies.
NASA Astrophysics Data System (ADS)
Madariaga, J. M.; Torre-Fdez, I.; Ruiz-Galende, P.; Aramendia, J.; Gomez-Nubla, L.; Fdez-Ortiz de Vallejuelo, S.; Maguregui, M.; Castro, K.; Arana, G.
2018-04-01
Advanced methodologies based on Raman spectroscopy are proposed to detect prebiotic and biotic molecules in returned samples from Mars: (a) optical microscopy with confocal micro-Raman, (b) the SCA instrument, (c) Raman Imaging. Examples for NWA 6148.
NASA Astrophysics Data System (ADS)
Košařová, Veronika; Hradil, David; Hradilová, Janka; Čermáková, Zdeňka; Němec, Ivan; Schreiner, Manfred
2016-03-01
Twenty one mock-up samples containing inorganic pigments primarily used at the turn of the 19th and 20th century were selected for comparative study and measured by micro-Raman and portable Raman spectrometers. They included pure grounds (chalk-based, earth-based and lithopone-based), grounds covered by resin-based varnish, and different paint layers containing mixtures of white, yellow, orange, red, green, blue and black pigments, usually in combination with white pigments (titanium, zinc and barium whites or chalk). In addition, ten micro-samples obtained from seven paintings of two world-famous modern painters Edvard Munch and František Kupka have been investigated. Infrared reflection spectroscopy (FTIR), portable X-ray fluorescence (XRF) and scanning electron microscopy with energy dispersive spectroscopy (SEM-EDS) were used as supplementary methods. The measurements showed that blue pigments (ultramarine, Prussian blue and azurite), vermilion and ivory black in mixture with whites provided characteristic Raman spectra, while Co-, Cd- and Cr- pigments' bands were suppressed by fluorescence. The best success rate of micro-Raman spectroscopy has been achieved using the 780 nm excitation, however, the sensitivity of this excitation laser in a portable Raman instrument significantly decreased. The analyses of micro-samples of paintings by E. Munch and F. Kupka showed that micro-Raman spectroscopy identified pigments which would remain unidentified if analyzed only by SEM-EDS (zinc yellow, Prussian blue). On the other hand, chromium oxide green and ultramarine were not detected together in a sample due to overlap of their main bands. In those cases, it is always necessary to complement Raman analysis with other analytical methods.
A method based on coffee-ring deposition confocal Raman spectroscopy of analysis of melamine in milk
NASA Astrophysics Data System (ADS)
Tan, Zong; Chen, Da
2016-10-01
In this work, an economical and high-efficiency method for detection of melamine in milk was developed. The enrichment effect of coffee-ring was combined with the micro-region analysis of confocal Raman spectroscopy, in addition, assisted with chemometric algorithmthe. Consequently, a desired result was obtained that the LOD of melamine in this method was 1 ppm, which was excellent because the sensitivity of conventional Raman detection was generally low. Furthermore, the whole process were processed in an easily available condition with almost no chemical reagents consumption, and the chosen substrates for the formation of coffee-ring were reusable. Thus, the method is environmental friendly and has a great potential application in food safety inspection.
Multi-fiber strains measured by micro-Raman spectroscopy: Principles and experiments
NASA Astrophysics Data System (ADS)
Lei, Zhenkun; Wang, Yunfeng; Qin, Fuyong; Qiu, Wei; Bai, Ruixiang; Chen, Xiaogang
2016-02-01
Based on widely used axial strain measurement method of Kevlar single fiber, an original theoretical model and measurement principle of application of micro-Raman spectroscopy to multi-fiber strains in a fiber bundle were established. The relationship between the nominal Raman shift of fiber bundle and the multi-fiber strains was deduced. The proposed principle for multi-fiber strains measurement is consistent with two special cases: single fiber deformation and multi-fiber deformation under equal strain. It is found experimentally that the distribution of Raman scattering intensity of a Kevlar 49 fiber as a function of distance between a fiber and the laser spot center follows a Gaussian function. Combining the Raman-shift/strain relationship of the Kevlar 49 single fiber and the uniaxial tension measured by micro-Raman spectroscopy, the Raman shift as a function of strain was obtained. Then the Raman peak at 1610 cm-1 for the Kevlar 49 fiber was fitted to a Lorentzian function and the FWHM showed a quadratic increase with the fiber strain. Finally, a dual-fiber tensile experiment was performed to verify the adequacy of the Raman technique for the measurement of multi-fiber strains.
NASA Astrophysics Data System (ADS)
Delfino, I.; Camerlingo, C.; Zenone, F.; Perna, G.; Capozzi, V.; Cirillo, N.; Gaeta, G. M.; De Mol, E.; Lepore, M.
2009-02-01
Pemphigus vulgaris (PV) is a potentially fatal autoimmune disease that cause blistering of the skin and oral cavity. It is characterized by disruption of cell-cell adhesion within the suprabasal layers of epithelium, a phenomenon termed acantholysis Patients with PV develop IgG autoantibodies against normal constituents of the intercellular substance of keratinocytes. The mechanisms by which such autoantibodies induce blisters are not clearly understood. The qualitative analysis of such effects provides important clues in the search for a specific diagnosis, and the quantitative analysis of biochemical abnormalities is important in measuring the extent of the disease process, designing therapy and evaluating the efficacy of treatment. Improved diagnostic techniques could permit the recognition of more subtle forms of disease and reveal incipient lesions clinically unapparent, so that progression of potentially severe forms could be reversed with appropriate treatment. In this paper, we report the results of our micro-Raman spectroscopy study on tissue and blood serum samples from ill, recovered and under therapy PV patients. The complexity of the differences among their characteristic Raman spectra has required a specific strategy to obtain reliable information on the illness stage of the patients For this purpose, wavelet techniques and advanced multivariate analysis methods have been developed and applied to the experimental Raman spectra. Promising results have been obtained.
Sharma, Shiv K; Misra, Anupam K; Lucey, Paul G; Lentz, Rachel C F
2009-08-01
The authors have developed an integrated remote Raman and laser-induced breakdown spectroscopy (LIBS) system for measuring both the Raman and LIBS spectra of minerals with a single 532 nm laser line of 35 mJ/pulse and 20 Hz. The instrument has been used for analyzing both Raman and LIBS spectra of carbonates, sulfates, hydrous and anhydrous silicates, and iron oxide minerals in air. These experiments demonstrate that by focusing a frequency-doubled 532 nm Nd:YAG pulsed laser beam with a 10x beam expander to a 529-microm diameter spot on a mineral surface located at 9 m, it is possible to measure simultaneously both the remote Raman and LIBS spectra of calcite, gypsum and olivine by adjusting the laser power electronically. The spectra of calcite, gypsum, and olivine contain fingerprint Raman lines; however, it was not possible to measure the remote Raman spectra of magnetite and hematite at 9 m because of strong absorption of 532 nm laser radiation and low intensities of Raman lines from these minerals. The remote LIBS spectra of both magnetite and hematite contain common iron emission lines but show difference in the minor amount of Li present in these two minerals. Remote Raman and LIBS spectra of a number of carbonates, sulfates, feldspars and phyllosilicates at a distance of 9 m were measured with a 532-nm laser operating at 35 mJ/pulse and by changing photon flux density at the sample by varying the spot diameter from 10 mm for Raman to 530 microm for LIBS measurements. The complementary nature of these spectra is highlighted and discussed. The combined Raman and LIBS system can also be re-configured to perform micro-Raman and micro-LIBS analyses, which have applications in trace/residue analysis and analysis of very small samples in the nano-gram range.
Bagnall, Kevin R; Moore, Elizabeth A; Badescu, Stefan C; Zhang, Lenan; Wang, Evelyn N
2017-11-01
As semiconductor devices based on silicon reach their intrinsic material limits, compound semiconductors, such as gallium nitride (GaN), are gaining increasing interest for high performance, solid-state transistor applications. Unfortunately, higher voltage, current, and/or power levels in GaN high electron mobility transistors (HEMTs) often result in elevated device temperatures, degraded performance, and shorter lifetimes. Although micro-Raman spectroscopy has become one of the most popular techniques for measuring localized temperature rise in GaN HEMTs for reliability assessment, decoupling the effects of temperature, mechanical stress, and electric field on the optical phonon frequencies measured by micro-Raman spectroscopy is challenging. In this work, we demonstrate the simultaneous measurement of temperature rise, inverse piezoelectric stress, thermoelastic stress, and vertical electric field via micro-Raman spectroscopy from the shifts of the E 2 (high), A 1 longitudinal optical (LO), and E 2 (low) optical phonon frequencies in wurtzite GaN. We also validate experimentally that the pinched OFF state as the unpowered reference accurately measures the temperature rise by removing the effect of the vertical electric field on the Raman spectrum and that the vertical electric field is approximately the same whether the channel is open or closed. Our experimental results are in good quantitative agreement with a 3D electro-thermo-mechanical model of the HEMT we tested and indicate that the GaN buffer acts as a semi-insulating, p-type material due to the presence of deep acceptors in the lower half of the bandgap. This implementation of micro-Raman spectroscopy offers an exciting opportunity to simultaneously probe thermal, mechanical, and electrical phenomena in semiconductor devices under bias, providing unique insight into the complex physics that describes device behavior and reliability. Although GaN HEMTs have been specifically used in this study to demonstrate its viability, this technique is applicable to any solid-state material with a suitable Raman response and will likely enable new measurement capabilities in a wide variety of scientific and engineering applications.
NASA Astrophysics Data System (ADS)
Bagnall, Kevin R.; Moore, Elizabeth A.; Badescu, Stefan C.; Zhang, Lenan; Wang, Evelyn N.
2017-11-01
As semiconductor devices based on silicon reach their intrinsic material limits, compound semiconductors, such as gallium nitride (GaN), are gaining increasing interest for high performance, solid-state transistor applications. Unfortunately, higher voltage, current, and/or power levels in GaN high electron mobility transistors (HEMTs) often result in elevated device temperatures, degraded performance, and shorter lifetimes. Although micro-Raman spectroscopy has become one of the most popular techniques for measuring localized temperature rise in GaN HEMTs for reliability assessment, decoupling the effects of temperature, mechanical stress, and electric field on the optical phonon frequencies measured by micro-Raman spectroscopy is challenging. In this work, we demonstrate the simultaneous measurement of temperature rise, inverse piezoelectric stress, thermoelastic stress, and vertical electric field via micro-Raman spectroscopy from the shifts of the E2 (high), A1 longitudinal optical (LO), and E2 (low) optical phonon frequencies in wurtzite GaN. We also validate experimentally that the pinched OFF state as the unpowered reference accurately measures the temperature rise by removing the effect of the vertical electric field on the Raman spectrum and that the vertical electric field is approximately the same whether the channel is open or closed. Our experimental results are in good quantitative agreement with a 3D electro-thermo-mechanical model of the HEMT we tested and indicate that the GaN buffer acts as a semi-insulating, p-type material due to the presence of deep acceptors in the lower half of the bandgap. This implementation of micro-Raman spectroscopy offers an exciting opportunity to simultaneously probe thermal, mechanical, and electrical phenomena in semiconductor devices under bias, providing unique insight into the complex physics that describes device behavior and reliability. Although GaN HEMTs have been specifically used in this study to demonstrate its viability, this technique is applicable to any solid-state material with a suitable Raman response and will likely enable new measurement capabilities in a wide variety of scientific and engineering applications.
NASA Astrophysics Data System (ADS)
Chen, Zhong; Huang, Jingyun; Wang, Ye; Yang, Yefeng; Wu, Yongjun; Ye, Zhizhen
2012-09-01
Potassium niobate micro-hexagonal tablets were synthesized through hydrothermal reaction with KOH, H2O and Nb2O5 as source materials by using a polycrystalline Al2O3 as substrate. X-ray diffraction, Raman spectra and selected area electron diffraction analysis results indicated that the tablets exhibit monoclinic phase structure and are highly crystallized. Meanwhile, piezoelectric property of the micro-hexagonal tablets was investigated. The as-synthesized tablets exhibit excellent piezoactivities in the experiments, and an effective piezoelectric coefficient of around 80 pm/V was obtained. The tablets have huge potential applications in micro/nano-integrated piezoelectric and optical devices.
NASA Astrophysics Data System (ADS)
Li, Jiajia; Li, Rongxi; Zhao, Bangsheng; Guo, Hui; Zhang, Shuan; Cheng, Jinghua; Wu, Xiaoli
2018-04-01
The use of Micro-Laser Raman spectroscopy technology for quantitatively determining gas carbon isotope composition is presented. In this study, 12CO2 and 13CO2 were mixed with N2 at various molar fraction ratios to obtain Raman quantification factors (F12CO2 and F13CO2), which provide a theoretical basis for calculating the δ13C value. And the corresponding values were 0.523 (0 < C12CO2/CN2 < 2) and 1.11998 (0 < C13CO2/CN2 < 1.5) respectively. It has shown that the representative Raman peak area can be used for the determination of δ13C values within the relative errors range of 0.076% to 1.154% in 13CO2/12CO2 binary mixtures when F12CO2/F13CO2 is 0.466972625. In addition, measurement of δ13C values by Micro-Laser Raman analysis were carried out on natural CO2 gas from Shengli Oil-field at room temperature under different pressures. The δ13C values obtained by Micro-Laser Raman spectroscopy technology and Isotope Ratio Mass Spectrometry (IRMS) technology are in good agreement with each other, and the relative errors range of δ13C values is 1.232%-6.964%. This research provides a fundamental analysis tool for determining gas carbon isotope composition (δ13C values) quantitatively by using Micro-Laser Raman spectroscopy. Experiment of results demonstrates that this method has the potential for obtaining δ13C values in natural CO2 gas reservoirs.
NASA Astrophysics Data System (ADS)
Surmacki, Jakub M.; Quirós Gonzalez, Isabel; Bohndiek, Sarah E.
2018-02-01
Oxidative stress in cancer is implicated in tumor progression, being associated with increased therapy resistance and metastasis. Conventional approaches for monitoring oxidative stress in tissue such as high-performance liquid chromatography and immunohistochemistry are bulk measurements and destroy the sample, meaning that longitudinal monitoring of cancer cell heterogeneity remains elusive. Raman spectroscopy has the potential to overcome this challenge, providing a chemically specific, label free readout from single living cells. Here, we applied a standardized protocol for label-free confocal Raman micro-spectroscopy in living cells to monitor oxidative stress in bronchial cells. We used a quartz substrate in a commercial cell chamber contained within a microscope incubator providing culture media for cell maintenance. We studied the effect of a potent reactive oxygen species inducer, tert-butyl hydroperoxide (TBHP), and antioxidant, N-acetyl-L-cysteine (NAC) on living cells from a human bronchial epithelial cells (HBEC). We found that the Raman bands corresponding to nucleic acids, proteins and lipids were significantly different (p<0.05) for control, TBHP, and NAC. Encouragingly, partial least squares discriminant analysis applied to our data showed high sensitivity and specificity for identification of control (87.3%, 71.7%), NAC (92.3%, 85.1%) and TBHP (86.9%, 92.9%). These results suggest that confocal Raman micro-spectroscopy may be able to monitor the biological impact of oxidative and reductive processes in cells, hence enabling longitudinal studies of oxidative stress in therapy resistance and metastasis at the single cell level.
Rapid identification of single microbes by various Raman spectroscopic techniques
NASA Astrophysics Data System (ADS)
Rösch, Petra; Harz, Michaela; Schmitt, Michael; Peschke, Klaus-Dieter; Ronneberger, Olaf; Burkhardt, Hans; Motzkus, Hans-Walter; Lankers, Markus; Hofer, Stefan; Thiele, Hans; Popp, Jürgen
2006-02-01
A fast and unambiguous identification of microorganisms is necessary not only for medical purposes but also in technical processes such as the production of pharmaceuticals. Conventional microbiological identification methods are based on the morphology and the ability of microbes to grow under different conditions on various cultivation media depending on their biochemical properties. These methods require pure cultures which need cultivation of at least 6 h but normally much longer. Recently also additional methods to identify bacteria are established e.g. mass spectroscopy, polymerase chain reaction (PCR), flow cytometry or fluorescence spectroscopy. Alternative approaches for the identification of microorganisms are vibrational spectroscopic techniques. With Raman spectroscopy a spectroscopic fingerprint of the microorganisms can be achieved. Using UV-resonance Raman spectroscopy (UVRR) macromolecules like DNA/RNA and proteins are resonantly enhanced. With an excitation wavelength of e.g. 244 nm it is possible to determine the ratio of guanine/cytosine to all DNA bases which allows a genotypic identification of microorganisms. The application of UVRR requires a large amount of microorganisms (> 10 6 cells) e.g. at least a micro colony. For the analysis of single cells micro-Raman spectroscopy with an excitation wavelength of 532 nm can be used. Here, the obtained information is from all type of molecules inside the cells which lead to a chemotaxonomic identification. In this contribution we show how wavelength dependent Raman spectroscopy yields significant molecular information applicable for the identification of microorganisms on a single cell level.
Delfino, Ines; Perna, Giuseppe; Lasalvia, Maria; Capozzi, Vito; Manti, Lorenzo; Camerlingo, Carlo; Lepore, Maria
2015-03-01
A micro-Raman spectroscopy investigation has been performed in vitro on single human mammary epithelial cells after irradiation by graded x-ray doses. The analysis by principal component analysis (PCA) and interval-PCA (i-PCA) methods has allowed us to point out the small differences in the Raman spectra induced by irradiation. This experimental approach has enabled us to delineate radiation-induced changes in protein, nucleic acid, lipid, and carbohydrate content. In particular, the dose dependence of PCA and i-PCA components has been analyzed. Our results have confirmed that micro-Raman spectroscopy coupled to properly chosen data analysis methods is a very sensitive technique to detect early molecular changes at the single-cell level following exposure to ionizing radiation. This would help in developing innovative approaches to monitor radiation cancer radiotherapy outcome so as to reduce the overall radiation dose and minimize damage to the surrounding healthy cells, both aspects being of great importance in the field of radiation therapy.
Resonance Raman spectroscopy in malaria research.
Wood, Bayden R; McNaughton, Don
2006-10-01
In recent years, the field of Raman spectroscopy has witnessed a surge in technological development, with the incorporation of ultrasensitive, charge-coupled devices, improved laser sources and precision Rayleigh-filter systems. This has led to the development of sensitive confocal micro-Raman spectrometers and imaging spectrometers that are capable of obtaining high spatial-resolution spectra and images of subcellular components within single living cells. This review reports on the application of resonance micro-Raman spectroscopy to the study of malaria pigment (hemozoin), a by-product of hemoglobin catabolization by the malaria parasite, which is an important target site for antimalarial drugs. The review aims to briefly describe recent studies on the application of this technology, elucidate molecular and electronic properties of the malaria pigment and its synthetic analog beta-hematin, provide insight into the mechanism of hemozoin formation within the food vacuole of the parasite, and comment on developing strategies for using this technology in drug-screening protocols.
Ultralow-threshold Raman lasing with CaF2 resonators.
Grudinin, Ivan S; Maleki, Lute
2007-01-15
We demonstrate efficient Raman lasing with CaF2 whispering-gallery-mode resonators. Continuous-wave emission threshold is shown to be possible below 1 microW with a 5mm cavity, which is to our knowledge orders of magnitude lower than in any other Raman source. Low-threshold lasing is made possible by the ultrahigh optical quality factor of the cavity, of the order of Q=5x10(10). Stokes components of up to the fifth order were observed at a pump power of 160 microW, and up to the eighth order at 1 mW. A lasing threshold of 15 microW was also observed in a 100 microm CaF2 microcavity. Potential applications are discussed.
Micro-Raman Spectroscopy of Silver Nanoparticle Induced Stress on Optically-Trapped Stem Cells
Bankapur, Aseefhali; Krishnamurthy, R. Sagar; Zachariah, Elsa; Santhosh, Chidangil; Chougule, Basavaraj; Praveen, Bhavishna; Valiathan, Manna; Mathur, Deepak
2012-01-01
We report here results of a single-cell Raman spectroscopy study of stress effects induced by silver nanoparticles in human mesenchymal stem cells (hMSCs). A high-sensitivity, high-resolution Raman Tweezers set-up has been used to monitor nanoparticle-induced biochemical changes in optically-trapped single cells. Our micro-Raman spectroscopic study reveals that hMSCs treated with silver nanoparticles undergo oxidative stress at doping levels in excess of 2 µg/ml, with results of a statistical analysis of Raman spectra suggesting that the induced stress becomes more dominant at nanoparticle concentration levels above 3 µg/ml. PMID:22514708
Li, Jiajia; Li, Rongxi; Zhao, Bangsheng; Guo, Hui; Zhang, Shuan; Cheng, Jinghua; Wu, Xiaoli
2018-04-15
The use of Micro-Laser Raman spectroscopy technology for quantitatively determining gas carbon isotope composition is presented. In this study, 12 CO 2 and 13 CO 2 were mixed with N 2 at various molar fraction ratios to obtain Raman quantification factors (F 12CO2 and F 13CO2 ), which provide a theoretical basis for calculating the δ 13 C value. And the corresponding values were 0.523 (0
Raman Spectroscopy of Optically Trapped Single Biological Micro-Particles
Redding, Brandon; Schwab, Mark J.; Pan, Yong-le
2015-01-01
The combination of optical trapping with Raman spectroscopy provides a powerful method for the study, characterization, and identification of biological micro-particles. In essence, optical trapping helps to overcome the limitation imposed by the relative inefficiency of the Raman scattering process. This allows Raman spectroscopy to be applied to individual biological particles in air and in liquid, providing the potential for particle identification with high specificity, longitudinal studies of changes in particle composition, and characterization of the heterogeneity of individual particles in a population. In this review, we introduce the techniques used to integrate Raman spectroscopy with optical trapping in order to study individual biological particles in liquid and air. We then provide an overview of some of the most promising applications of this technique, highlighting the unique types of measurements enabled by the combination of Raman spectroscopy with optical trapping. Finally, we present a brief discussion of future research directions in the field. PMID:26247952
DNA-Encoded Raman-Active Anisotropic Nanoparticles for microRNA Detection.
Qi, Lin; Xiao, Mingshu; Wang, Xiwei; Wang, Cheng; Wang, Lihua; Song, Shiping; Qu, Xiangmeng; Li, Li; Shi, Jiye; Pei, Hao
2017-09-19
The development of highly sensitive and selective methods for the detection of microRNA (miRNA) has attracted tremendous attention because of its importance in fundamental biological studies and diagnostic applications. In this work, we develop DNA-encoded Raman-active anisotropic nanoparticles modified origami paper analytical devices (oPADs) for rapid, highly sensitive, and specific miRNA detection. The Raman-active anisotropic nanoparticles were prepared using 10-mer oligo-A, -T, -C, and -G to mediate the growth of Ag cubic seeds into Ag nanoparticles (AgNPs) with different morphologies. The resulting AgNPs were further encoded with DNA probes to serve as effective surface-enhanced Raman scattering (SERS) probes. The analytical device was then fabricated on a single piece of SERS probes loaded paper-based substrate and assembled based on the principles of origami. The addition of the target analyte amplifies the Raman signals on DNA-encoded AgNPs through a target-dependent, sequence specific DNA hybridization assembly. This simple and low-cost analytical device is generic and applicable to a variety of miRNAs, allowing detection sensitivity down to 1 pM and assay time within 15 min, and therefore holds promising applications in point-of-care diagnostics.
Noh, Jermim; Suh, Yung Doug; Park, Yong Ki; Jin, Seung Min; Kim, Soo Ho; Woo, Seong Ihl
2007-07-01
Combined micro-Raman/UV-visible (vis)/fluorescence spectroscopy system, which can evaluate an integrated array of more than 10,000 microsamples with a minimuma size of 5 microm within a few hours, has been developed for the first time. The array of microsamples is positioned on a computer-controlled XY translation microstage with a spatial resolution of 1 mum so that the spectra can be mapped with micron precision. Micro-Raman spectrometers have a high spectral resolution of about 2 cm(-1) over the wave number range of 150-3900 cm(-1), while UV-vis and fluorescence spectrometers have high spectral resolutions of 0.4 and 0.1 nm over the wavelength range of 190-900 nm, respectively. In particular, the signal-to-noise ratio of the micro-Raman spectroscopy has been improved by using a holographic Raman grating and a liquid-nitrogen-cooled charge-coupled device detector. The performance of the combined spectroscopy system has been demonstrated by the high-throughput screening of a combinatorial ferroelectric (i.e., BaTi(x)Zr(1-x)O(3)) library. This system makes possible the structure analysis of various materials including ferroelectrics, catalysts, phosphors, polymers, alloys, and so on for the development of novel materials and the ultrasensitive detection of trace amounts of pharmaceuticals and diagnostic agents.
Bridoux, Maxime C; Schwarzenberg, Adrián; Schramm, Sébastien; Cole, Richard B
2016-08-01
Direct Analysis in Real Time (DART™) high-resolution Orbitrap™ mass spectrometry (HRMS) in combination with Raman microscopy was used for the detailed molecular level characterization of explosives including not only the charge but also the complex matrix of binders, plasticizers, polymers, and other possible organic additives. A total of 15 defused military weapons including grenades, mines, rockets, submunitions, and mortars were examined. Swabs and wipes were used to collect trace (residual) amounts of explosives and their organic constituents from the defused military weapons and micrometer-size explosive particles were transferred using a vacuum suction-impact collection device (vacuum impactor) from wipe and swap samples to an impaction plate made of carbon. The particles deposited on the carbon plate were then characterized using micro-Raman spectroscopy followed by DART-HRMS providing fingerprint signatures of orthogonal nature. The optical microscope of the micro-Raman spectrometer was first used to localize and characterize the explosive charge on the impaction plate which was then targeted for identification by DART-HRMS analysis in both the negative and positive modes. Raman spectra of the explosives TNT, RDX and PETN were acquired from micrometer size particles and characterized by the presence of their characteristic Raman bands obtained directly at the surface of the impaction plate nondestructively without further sample preparation. Negative mode DART-HRMS confirmed the types of charges contained in the weapons (mainly TNT, RDX, HMX, and PETN; either as individual components or as mixtures). These energetic compounds were mainly detected as deprotonated species [M-H](-), or as adduct [M + (35)Cl](-), [M + (37)Cl](-), or [M + NO3](-) anions. Chloride adducts were promoted in the heated DART reagent gas by adding chloroform vapors to the helium stream using an "in-house" delivery method. When the polarity was switched to positive mode, DART-HRMS revealed a very complex distribution of polymeric binders (mainly polyethylene glycols and polypropylene glycols), plasticizers (e.g., dioctyl sebacate, tributyl phosphate), as well as wax-like compounds whose structural features could not be precisely assigned. In positive mode, compounds were identified either as protonated molecules or ammonium adduct species. These results clearly demonstrate the complementarity of micro-Raman microscopy combined with DART-MS. The former technique provides structural information on the type of explosives present at the surface of the sample, whereas the latter provides not only a confirmation of the nature of the explosive charge but also useful additional information regarding the nature of the complex organic matrix of binders, plasticizers, polymers, oils, and potentially other organic additives and contaminants present in the sample. Combining these two techniques provides a powerful tool for the screening, comprehensive characterization, and differentiation of particulate explosive samples for forensic sciences and homeland security applications. Graphical Abstract Comprehensive characterization of explosive particles collected from swipe samples by micro-Raman and DART™-HRMS.
O electrolyte for bio-application
NASA Astrophysics Data System (ADS)
Naddaf, M.; Almariri, A.
2014-09-01
Porous silicon (PS) has been prepared in the dark by anodic etching of n+-type (111) silicon substrate in a HF:HCl:C2H5OH:H2O2:H2O electrolyte. The processed PS layer is characterized by means of photoluminescence (PL) spectroscopy, scanning electron microscope (SEM), water contact angle (CA) measurements, Fourier transform infrared (FTIR) spectroscopy, X-ray photoelectron spectroscopy (XPS) and micro-Raman scattering. The CA of fresh PS layer is found to be ~142°. On aging at ambient conditions, the CA decreases gently to reach ~133° after 3 month, and then it is stabilized for a prolonged time of aging. The visible PL emission from the PS layer also exhibits a good stability against aging time. The FTIR and XPS measurements and analysis show that the stable aged PS layer has rather SiO2-rich surface. The micro/nanostructure nature of the PS layer is revealed from SEM and micro-Raman results and correlated to CA results. Stable hydrophobic surface of oxidized PS layer is attractive for bio-applications. The efficiency of the produced PS layers as an entrapping template for specific immobilization of IgG2a antibody via physical absorption process is demonstrated.
Raman micro-spectroscopy analysis of different sperm regions: a species comparison.
Amaral, S; Da Costa, R; Wübbeling, F; Redmann, K; Schlatt, S
2018-04-01
Is Raman micro-spectroscopy a valid approach to assess the biochemical hallmarks of sperm regions (head, midpiece and tail) in four different species? Non-invasive Raman micro-spectroscopy provides spectral patterns enabling the biochemical characterization of the three sperm regions in the four species, revealing however high similarities for each region among species. Raman micro-spectroscopy has been described as an innovative method to assess sperm features having the potential to be used as a non-invasive selection tool. However, except for nuclear DNA, the identification and assignment of spectral bands in Raman-profiles to the different sperm regions is scarce and controversial. Raman spectra from head, midpiece and tail of four different species were obtained. Sperm samples were collected and smeared on microscope slides. Air dried samples were subjected to Raman analysis using previously standardized procedures. Sperm samples from (i) two donors attending the infertility clinic at the Centre of Reproductive Medicine and Andrology; (ii) two C57BL/6 -TgN (ACTbEGFP) 1Osb adult mice; (iii) two adult Cynomolgus monkeys (Macaca fascicularis) and (iv) two sea urchins (Arbacia punctulata) were used to characterize and compare their spectral profiles. Differences and similarities were confirmed by principal component analysis (PCA). Several novel region-specific peaks were identified. The three regions could be differentiated by distinctive Raman patterns irrespective of the species. However, regardless of the specie, their main spectral pattern remains mostly unchanged. These results were corroborated by the PCA analysis and suggest that the basic constituents of spermatozoa are biochemically similar among species. Further research should be performed in live sperm to validate the detected spectral bands and their use as markers of distinctive regions. Raman peaks that have never been described in the sperm cell were detected. Particularly important are those that are unique to the midpiece as they might be a reference to the identification of sperm mitochondria, whose function is highly correlated with that of sperm. In the future, Raman micro-spectroscopy has the potential to be applied in assessment of male fertility. N/A. This work was supported by BMBF project 'Sperm Ident' (FKZ:13N13024) and the DAAD-CRUP bilateral exchange program (AI A06/16-57213087). S.A. is a recipient of a fellowship from the Portuguese foundation for science and technology (FCT-SFRH/BPD/110160/2015) and R.DC. is a recipient of a DAAD PhD stipend (91590556). There is no competing interest.
Ghita, Adrian; Pascut, Flavius C; Sottile, Virginie; Denning, Chris; Notingher, Ioan
Stem cell therapy is widely acknowledged as a key medical technology of the 21st century which may provide treatments for many currently incurable diseases. These cells have an enormous potential for cell replacement therapies to cure diseases such as Parkinson's disease, diabetes and cardiovascular disorders, as well as in tissue engineering as a reliable cell source for providing grafts to replace and repair diseased tissues. Nevertheless, the progress in this field has been difficult in part because of lack of techniques that can measure non-invasively the molecular properties of cells. Such repeated measurements can be used to evaluate the culture conditions during differentiation, cell quality and phenotype heterogeneity of stem cell progeny. Raman spectroscopy is an optical technique based on inelastic scattering of laser photons by molecular vibrations of cellular molecules and can be used to provide chemical fingerprints of cells or organelles without fixation, lysis or use of labels and other contrast enhancing chemicals. Because differentiated cells are specialized to perform specific functions, these cells produce specific biochemicals that can be detected by Raman micro-spectroscopy. This mini-review paper describes applications of Raman micro-scpectroscopy to measure moleculare properties of stem cells during differentiation in-vitro. The paper focuses on time- and spatially-resolved Raman spectral measurements that allow repeated investigation of live stem cells in-vitro.
Guo, Tian-Long; Li, Ji-Guang; Sun, Xudong; Sakka, Yoshio
2016-04-01
Galvanic growth of Ag nano/micro-structures on Cu micro-grid was systematically studied for surface-enhanced Raman scattering (SERS) applications. Detailed characterizations via FE-SEM and HR-TEM showed that processing parameters, (reaction time, Ag(+) concentration, and PVP addition) all substantially affect thermodynamics/kinetics of the replacement reaction to yield substrates of significantly different microstructures/homogeneities and thus varied SERS performances (sensitivity, enhancement factor, and reproducibility) of the Ag substrates in the detection of R6G analyte. PVP as an additive was shown to notably alter nucleation/growth behaviors of the Ag crystals and promote the deposition of dense and uniform Ag films of nearly monodisperse polyhedrons/nanoplates through suppressing dendrites crystallization. Under optimized synthesis (50mM of Ag(+), 30s of reaction, and 700 wt.% of PVP), Ag substrates exhibiting a high Raman signal enhancement factor of ~1.1 × 10(6) and a low relative standard deviation of ~0.13 in the repeated detection of 10 μM R6G were obtained. The facile deposition and excellent performance reported in this work may allow the Ag microstructures to find wider SERS applications. Moreover, growth mechanisms of the different Ag nano/micro-structures were discussed based on extensive FE-SEM and HR-TEM analysis. Copyright © 2015 Elsevier B.V. All rights reserved.
Nanoengineered capsules for selective SERS analysis of biological samples
NASA Astrophysics Data System (ADS)
You, Yil-Hwan; Schechinger, Monika; Locke, Andrea; Coté, Gerard; McShane, Mike
2018-02-01
Metal nanoparticles conjugated with DNA oligomers have been intensively studied for a variety of applications, including optical diagnostics. Assays based on aggregation of DNA-coated particles in proportion to the concentration of target analyte have not been widely adopted for clinical analysis, however, largely due to the nonspecific responses observed in complex biofluids. While sample pre-preparation such as dialysis is helpful to enable selective sensing, here we sought to prove that assay encapsulation in hollow microcapsules could remove this requirement and thereby facilitate more rapid analysis on complex samples. Gold nanoparticle-based assays were incorporated into capsules comprising polyelectrolyte multilayer (PEMs), and the response to small molecule targets and larger proteins were compared. Gold nanoparticles were able to selectively sense small Raman dyes (Rhodamine 6G) in the presence of large protein molecules (BSA) when encapsulated. A ratiometric based microRNA-17 sensing assay exhibited drastic reduction in response after encapsulation, with statistically-significant relative Raman intensity changes only at a microRNA-17 concentration of 10 nM compared to a range of 0-500 nM for the corresponding solution-phase response.
Liu, X-L; Liu, H-N; Tan, P-H
2017-08-01
Resonant Raman spectroscopy requires that the wavelength of the laser used is close to that of an electronic transition. A tunable laser source and a triple spectrometer are usually necessary for resonant Raman profile measurements. However, such a system is complex with low signal throughput, which limits its wide application by scientific community. Here, a tunable micro-Raman spectroscopy system based on the supercontinuum laser, transmission grating, tunable filters, and single-stage spectrometer is introduced to measure the resonant Raman profile. The supercontinuum laser in combination with transmission grating makes a tunable excitation source with a bandwidth of sub-nanometer. Such a system exhibits continuous excitation tunability and high signal throughput. Its good performance and flexible tunability are verified by resonant Raman profile measurement of twisted bilayer graphene, which demonstrates its potential application prospect for resonant Raman spectroscopy.
Role of Raman spectroscopy and surface enhanced Raman spectroscopy in colorectal cancer
Jenkins, Cerys A; Lewis, Paul D; Dunstan, Peter R; Harris, Dean A
2016-01-01
Colorectal cancer (CRC) is the fourth most common cancer in the United Kingdom and is the second largest cause of cancer related death in the United Kingdom after lung cancer. Currently in the United Kingdom there is not a diagnostic test that has sufficient differentiation between patients with cancer and those without cancer so the current referral system relies on symptomatic presentation in a primary care setting. Raman spectroscopy and surface enhanced Raman spectroscopy (SERS) are forms of vibrational spectroscopy that offer a non-destructive method to gain molecular information about biological samples. The techniques offer a wide range of applications from in vivo or in vitro diagnostics using endoscopic probes, to the use of micro-spectrometers for analysis of biofluids. The techniques have the potential to detect molecular changes prior to any morphological changes occurring in the tissue and therefore could offer many possibilities to aid the detection of CRC. The purpose of this review is to look at the current state of diagnostic technology in the United Kingdom. The development of Raman spectroscopy and SERS in clinical applications relation for CRC will then be discussed. Finally, future areas of research of Raman/SERS as a clinical tool for the diagnosis of CRC are also discussed. PMID:27190582
NASA Astrophysics Data System (ADS)
Liu, Nan; Steele, Andrew; Nittler, Larry R.; Stroud, Rhonda M.; De Gregorio, Bradley T.; Alexander, Conel M. O'D.; Wang, Jianhua
2017-12-01
We report the development of a novel method to nondestructively identify presolar silicon carbide (SiC) grains with high initial 26Al/27Al ratios (>0.01) and extreme 13C-enrichments (12C/13C ≤ 10) by backscattered electron-energy dispersive X-ray (EDX) and micro-Raman analyses. Our survey of a large number of presolar SiC demonstrates that (1) 80% of core-collapse supernova and putative nova SiC can be identified by quantitative EDX and Raman analyses with >70% confidence; (2) 90% of presolar SiC are predominantly 3C-SiC, as indicated by their Raman transverse optical (TO) peak position and width; (3) presolar 3C-SiC with 12C/13C ≤ 10 show lower Raman TO phonon frequencies compared to mainstream 3C-SiC. The downward shifted phonon frequencies of the 13C-enriched SiC with concomitant peak broadening are a natural consequence of isotope substitution. 13C-enriched SiC can therefore be identified by micro-Raman analysis; (4) larger shifts in the Raman TO peak position and width indicate deviations from the ideal 3C structure, including rare polytypes. Coordinated transmission electron microscopy analysis of one X and one mainstream SiC grain found them to be of 6H and 15R polytypes, respectively; (5) our correlated Raman and NanoSIMS study of mainstream SiC shows that high nitrogen content is a dominant factor in causing mainstream SiC Raman peak broadening without significant peak shifts; and (6) we found that the SiC condensation conditions in different stellar sites are astonishingly similar, except for X grains, which often condensed more rapidly and at higher atmospheric densities and temperatures, resulting in a higher fraction of grains with much downward shifted and broadened Raman TO peaks.
Rösch, Petra; Harz, Michaela; Schmitt, Michael; Peschke, Klaus-Dieter; Ronneberger, Olaf; Burkhardt, Hans; Motzkus, Hans-Walter; Lankers, Markus; Hofer, Stefan; Thiele, Hans; Popp, Jürgen
2005-03-01
Microorganisms, such as bacteria, which might be present as contamination inside an industrial food or pharmaceutical clean room process need to be identified on short time scales in order to minimize possible health hazards as well as production downtimes causing financial deficits. Here we describe the first results of single-particle micro-Raman measurements in combination with a classification method, the so-called support vector machine technique, allowing for a fast, reliable, and nondestructive online identification method for single bacteria.
Rösch, Petra; Harz, Michaela; Schmitt, Michael; Peschke, Klaus-Dieter; Ronneberger, Olaf; Burkhardt, Hans; Motzkus, Hans-Walter; Lankers, Markus; Hofer, Stefan; Thiele, Hans; Popp, Jürgen
2005-01-01
Microorganisms, such as bacteria, which might be present as contamination inside an industrial food or pharmaceutical clean room process need to be identified on short time scales in order to minimize possible health hazards as well as production downtimes causing financial deficits. Here we describe the first results of single-particle micro-Raman measurements in combination with a classification method, the so-called support vector machine technique, allowing for a fast, reliable, and nondestructive online identification method for single bacteria. PMID:15746368
Vandenabeele, Peter; Conti, Claudia; Rousaki, Anastasia; Moens, Luc; Realini, Marco; Matousek, Pavel
2017-09-05
Microspatially offset Raman spectroscopy (micro-SORS) has been proposed as a valuable approach to sample molecular information from layers that are covered by a turbid (nontransparent) layer. However, when large magnifications are involved, the approach is not straightforward, as spatial constraints exist to position the laser beam and the objective lens with the external beam delivery or, with internal beam delivery, the maximum spatial offset achievable is restricted. To overcome these limitations, we propose here a prototype of a new micro-SORS sensor, which uses bare glass fibers to transfer the laser radiation to the sample and to collect the Raman signal from a spatially offset zone to the Raman spectrometer. The concept also renders itself amenable to remote delivery and to the miniaturization of the probe head which could be beneficial for special applications, e.g., where access to sample areas is restricted. The basic applicability of this approach was demonstrated by studying several layered structure systems. Apart from proving the feasibility of the technique, also, practical aspects of the use of the prototype sensor are discussed.
NASA Technical Reports Server (NTRS)
Chan, Q. H. S.; Zolensky, M. E.
2015-01-01
Carbonates can potentially provide sites for organic materials to accrue and develop into complex macromolecules. This study examines the organics associated with carbonates in carbonaceous chondrites using micron-Raman imaging.
NASA Technical Reports Server (NTRS)
Chan, Q. H. S.; Zolensky, M. E.
2015-01-01
Carbonates can potentially provide sites for organic materials to accrue and develop into complex macromolecules. This study examines the organics associated with carbonates in carbonaceous chondrites using µ-Raman imaging.
NASA Astrophysics Data System (ADS)
Long, Kailin; Du, Deyang; Luo, Xiaoguang; Zhao, Weiwei; Wu, Zhangting; Si, Lifang; Qiu, Teng
2014-08-01
This work reports a facile method to fabricate gold coated copper(II) hydroxide pine-needle-like micro/nanostructures for surface-enhanced Raman scattering (SERS) application. The effects of reaction parameters on the shape, size and surface morphology of the products are systematically investigated. The as-prepared 3D hierarchical structures have the advantage of a large surface area available for the formation of hot spots and the adsorption of target analytes, thus dramatically improving the Raman signals. The finite difference time domain calculations indicate that the pine-needle-like model pattern may demonstrate a high quality SERS property owing to the high density and abundant hot spot characteristic in closely spaced needle-like arms.
Rividi, Nicolas; van Zuilen, Mark; Philippot, Pascal; Ménez, Bénédicte; Godard, Gaston; Poidatz, Emmanuel
2010-04-01
Stromatolite structures in Early Archean carbonate deposits form an important clue for the existence of life in the earliest part of Earth's history. Since Mars is thought to have had similar environmental conditions early in its history, the question arises as to whether such stromatolite structures also evolved there. Here, we explore the capability of Raman spectroscopy to make semiquantitative estimates of solid solutions in the Ca-Mg-Fe(+Mn) carbonate system, and we assess its use as a rover-based technique for stromatolite characterization during future Mars missions. Raman microspectroscopy analysis was performed on a set of carbonate standards (calcite, ankerite, dolomite, siderite, and magnesite) of known composition. We show that Raman band shifts of siderite-magnesite and ankerite-dolomite solid solutions display a well-defined positive correlation (r(2) > 0.9) with the Mg# = 100 x Mg/(Mg + Fe + Mn + Ca) of the carbonate analyzed. Raman shifts calibrated as a function of Mg# were used in turn to evaluate the chemical composition of carbonates. Raman analysis of a suite of carbonates (siderite, sidero-magnesite, ankerite, and dolomite) of hydrothermal and sedimentary origin from the ca. 3.2 Ga old Barite Syncline, Barberton greenstone belt, South Africa, and from the ca. 3.5 Ga old Dresser Formation, Pilbara Craton, Western Australia, show good compositional agreement with electron microprobe analyses. These results indicate that Raman spectroscopy can provide direct information on the composition and structure of carbonates on planetary surfaces.
Paiva, Eduardo M; da Silva, Vitor H; Poppi, Ronei J; Pereira, Claudete F; Rohwedder, Jarbas J R
2018-05-12
This work reports on the use of micro- and macro-Raman measurements for quantification of mebendazole (MBZ) polymorphs A, B, and C in mixtures. Three Raman spectrophotometers were studied with a laser spot size of 3, 80 and 100 μm and spectral resolutions of 3.9, 9 and 4 cm -1 , respectively. The samples studied were ternary mixtures varying the MBZ polymorphs A and C from 0 to 100% and polymorph B from 0 to 30%. Partial Least Squares (PLS) regression models were developed using the pre-processing spectra (2nd derivative) of the ternary mixtures. The best performance was obtained when the macro-Raman configuration was applied, obtaining RMSEP values of 1.68%, 1.24% and 2.03% w/w for polymorphs A, B, and C, respectively. In general, micro-Raman presented worst results for MBZ polymorphs prediction because the spectra obtained with this configuration does not represent the bulk proportion of mixtures, which have different particle morphologies and sizes. In addition, the influence of these particle features on micro-Raman measurements was also studied. Finally, the results demonstrated that reliable analytical quantifying of MBZ polymorphs can be reached using a laser with wider area illuminated, thus enabling acquisition of more reproductive and representative spectra of the mixtures. Copyright © 2018 Elsevier B.V. All rights reserved.
Qiu, Xuejun; Huang, Hanchuan; Huang, Zhitong; Zhuang, Zhengfei; Guo, Zhouyi; Liu, Songhao
2017-01-01
Red light-emitting diodes (LED) were used to irradiate the isolated hypertension hemoglobin (Hb) and Raman spectra difference was recorded using confocal micro-Raman spectroscopy. Differences were observed between the controlled and irradiated Hb by comparing the spectra records. The Raman spectrum at the 1399 cm -1 band decreased following prolonged LED irradiation. The intensity of the 1639 cm -1 band decreased dramatically in the first five minutes and then gradually increased in a time-dependent manner. This observation indicated that LED irradiation increased the ability of oxygen binding in Hb. The appearance of the heme aggregation band at 1399 cm -1 , in addition to the oxygen marker band at 1639 cm -1 , indicated that, in our study, 30 min of irradiation with 15.0 mW was suitable for inhibiting heme aggregation and enhancing the oxygen-carrying capacity of Hb. Principal component analysis showed a one-to-one relationship between irradiated Hb at different time points and the corresponding Raman spectra. Our approach could be used to analyze the hemoglobin from patients with confocal micro-Raman spectroscopy and is helpful for developing new nondrug hypertension therapy.
Principle, system, and applications of tip-enhanced Raman spectroscopy
NASA Astrophysics Data System (ADS)
Zhang, MingQian; Wang, Rui; Wu, XiaoBin; Wang, Jia
2012-08-01
Raman spectroscopy is a powerful technique in chemical information characterization. However, this spectral method is subject to two obstacles in nano-material detection. One is diffraction limited spatial resolution, and the other is its inherent small Raman cross section and weak signaling. To resolve these problems, a new approach has been developed, denoted as tip-enhanced Raman spectroscopy (TERS). TERS is capable of high-resolution and high-sensitivity detection and demonstrated to be a promising spectroscopic and micro-topographic method to characterize nano-materials and nanostructures. In this paper, the principle and experimental system of TERS are discussed. The latest application of TERS in molecule detection, biological specimen identification, nanao-material characterization, and semi-conductor material determination with some specific experimental examples are presented.
Micro-Raman spectroscopy for identification and classification of UTI bacteria
NASA Astrophysics Data System (ADS)
Yogesha, M.; Chawla, Kiran; Acharya, Mahendra; Chidangil, Santhosh; Bankapur, Aseefhali
2017-07-01
Urinary tract infection (UTI) is one of the major clinical problems known to mankind, especially among adult women. Conventional methods for identification of UTI causing bacteria are time consuming and expensive. Therefore, a rapid and cost-effective method is desired. In the present study, five bacteria (one Gram-positive and four Gram-negative), most commonly known to cause UTI, have been identified and classified using micro-Raman spectroscopy combined with principal component analysis (PCA).
NASA Astrophysics Data System (ADS)
Schechinger, Monika; Marks, Haley; Locke, Andrea; Choudhury, Mahua; Cote, Gerard
2018-01-01
DNA-functionalized nanoparticles, when paired with surface-enhanced Raman spectroscopy (SERS), can rapidly detect microRNA. However, widespread use of this approach is hindered by drawbacks associated with large and expensive benchtop Raman microscopes. MicroRNA-17 (miRNA-17) has emerged as a potential epigenetic indicator of preeclampsia, a condition that occurs during pregnancy. Biomarker detection using an SERS point-of-care device could enable prompt diagnosis and prevention as early as the first trimester. Recently, strides have been made in developing portable Raman systems for field applications. An SERS assay for miRNA-17 was assessed and translated from traditional benchtop Raman microscopes to a handheld system. Three different photoactive molecules were compared as potential Raman reporter molecules: a chromophore, malachite green isothiocyanate (MGITC), a fluorophore, tetramethylrhodamine isothiocyanate, and a polarizable small molecule 5,5-dithio-bis-(2-nitrobenzoic acid) (DTNB). For the benchtop Raman microscope, the DTNB-labeled assay yielded the greatest sensitivity under 532-nm laser excitation, but the MGITC-labeled assay prevailed at 785 nm. Conversely, DTNB was preferable for the miniaturized 785-nm Raman system. This comparison showed significant SERS enhancement variation in response to 1-nM miRNA-17, implying that the sensitivity of the assay may be more heavily dependent on the excitation wavelength, instrumentation, and Raman reporter chosen than on the plasmonic coupling from DNA/miRNA-mediated nanoparticle assemblies.
NASA Astrophysics Data System (ADS)
Ammosova, Lena; Ankudze, Bright; Philip, Anish; Jiang, Yu; Pakkanen, Tuula T.; Pakkanen, Tapani A.
2018-01-01
Common methods to fabricate surface enhanced Raman scattering (SERS) substrates with controlled micro-nanohierarchy are often complex and expensive. In this study, we demonstrate a simple and cost effective method to fabricate SERS substrates with complex geometries. Microworking robot structuration is used to pattern a polypropylene (PP) substrate with micropits, facilitating protective microenvironment for brittle SiO2 inverse opal (IO) structure. Hierarchical SiO2 IO patterns were obtained using polystyrene (PS) spheres as a sacrificial template, and were selectively embedded into the hydrophilized PP micropits. The same microworking robot technique was subsequently used to deposit silver nanoparticle ink into the SiO2 IO cavities. The fabricated multi-level micro-nanohierarchy surface was studied to enhance Raman scattering of the 4-aminothiophenol (4-ATP) analyte molecule. The results show that the SERS performance of the micro-nanohierarchical substrate increases significantly the Raman scattering intensity compared to substrates with structured 2D surface geometries.
NASA Astrophysics Data System (ADS)
Falamas, A.; Kalra, S.; Chis, V.; Notingher, I.
2013-11-01
The aim of this study was to monitor the intracellular distribution of nucleic acids in human embryonic stem cells. Raman micro-spectroscopy and fluorescence imaging investigations were employed to obtain high-spatial resolution maps of nucleic acids. The DNA Raman signal was identified based on the 782 cm-1 band, while the RNA characteristic signal was detected based on the 813 cm-1 fingerprint band assigned to O-P-O symmetric stretching vibrations. Additionally, principal components analysis was performed and nucleic acids characteristic Raman signals were identified in the data set, which were plotted at each position in the cells. In this manner, high intensity RNA signal was identified in the cells nucleolus and cytoplasm, while the nucleus presented a much lower signal.
NASA Astrophysics Data System (ADS)
Pura, J. L.; Anaya, J.; Souto, J.; Prieto, A. C.; Rodríguez, A.; Rodríguez, T.; Periwal, P.; Baron, T.; Jiménez, J.
2018-03-01
Semiconductor nanowires (NWs) are the building blocks of future nanoelectronic devices. Furthermore, their large refractive index and reduced dimension make them suitable for nanophotonics. The study of the interaction between nanowires and visible light reveals resonances that promise light absorption/scattering engineering for photonic applications. Micro-Raman spectroscopy has been used as a characterization tool for semiconductor nanowires. The light/nanowire interaction can be experimentally assessed through the micro-Raman spectra of individual nanowires. As compared to both metallic and dielectric nanowires, semiconductor nanowires add additional tools for photon engineering. In particular, one can grow heterostructured nanowires, both axial and radial, and also one could modulate the doping level and the surface condition among other factors than can affect the light/NW interaction. We present herein a study of the optical response of group IV semiconductor nanowires to visible photons. The study is experimentally carried out through micro-Raman spectroscopy of different group IV nanowires, both homogeneous and axially heterostructured (SiGe/Si). The results are analyzed in terms of the electromagnetic modelling of the light/nanowire interaction using finite element methods. The presence of axial heterostructures is shown to produce electromagnetic resonances promising new photon engineering capabilities of semiconductor nanowires.
Harz, M; Rösch, P; Peschke, K-D; Ronneberger, O; Burkhardt, H; Popp, J
2005-11-01
Microbial contamination is not only a medical problem, but also plays a large role in pharmaceutical clean room production and food processing technology. Therefore many techniques were developed to achieve differentiation and identification of microorganisms. Among these methods vibrational spectroscopic techniques (IR, Raman and SERS) are useful tools because of their rapidity and sensitivity. Recently we have shown that micro-Raman spectroscopy in combination with a support vector machine is an extremely capable approach for a fast and reliable, non-destructive online identification of single bacteria belonging to different genera. In order to simulate different environmental conditions we analyzed in this contribution different Staphylococcus strains with varying cultivation conditions in order to evaluate our method with a reliable dataset. First, micro-Raman spectra of the bulk material and single bacterial cells that were grown under the same conditions were recorded and used separately for a distinct chemotaxonomic classification of the strains. Furthermore Raman spectra were recorded from single bacterial cells that were cultured under various conditions to study the influence of cultivation on the discrimination ability. This dataset was analyzed both with a hierarchical cluster analysis (HCA) and a support vector machine (SVM).
Microfluidic Cultivation and Laser Tweezers Raman Spectroscopy of E. coli under Antibiotic Stress
Pilát, Zdeněk; Bernatová, Silvie; Ježek, Jan; Kirchhoff, Johanna; Tannert, Astrid; Samek, Ota; Zemánek, Pavel
2018-01-01
Analyzing the cells in various body fluids can greatly deepen the understanding of the mechanisms governing the cellular physiology. Due to the variability of physiological and metabolic states, it is important to be able to perform such studies on individual cells. Therefore, we developed an optofluidic system in which we precisely manipulated and monitored individual cells of Escherichia coli. We tested optical micromanipulation in a microfluidic chamber chip by transferring individual bacteria into the chambers. We then subjected the cells in the chambers to antibiotic cefotaxime and we observed the changes by using time-lapse microscopy. Separately, we used laser tweezers Raman spectroscopy (LTRS) in a different micro-chamber chip to manipulate and analyze individual cefotaxime-treated E. coli cells. Additionally, we performed conventional Raman micro-spectroscopic measurements of E. coli cells in a micro-chamber. We found observable changes in the cellular morphology (cell elongation) and in Raman spectra, which were consistent with other recently published observations. The principal component analysis (PCA) of Raman data distinguished between the cefotaxime treated cells and control. We tested the capabilities of the optofluidic system and found it to be a reliable and versatile solution for this class of microbiological experiments. PMID:29783713
NASA Astrophysics Data System (ADS)
Ning, J. Q.; Zheng, C. C.; Zheng, L. X.; Xu, S. J.
2015-08-01
Spatially resolved Raman light scattering experiments were performed on a zinc-blende GaN/GaAs heterostructure with confocal micro-Raman scattering technique under the backscattering geometric configuration. By varying the illumination spot locations across the heterostructure interface, we found that the Raman light scattering spectral features change remarkably. The interface effect on the GaAs substrate manifested as a much broader lineshape of the transverse optical (TO) phonon mode. Two kinds of broadening mechanisms, namely, spatial correlation induced wave-vector relaxation effect and lattice-mismatch strain + compositional intermixing effect, have been identified. The former leads to the broadening of the TO mode at the low-energy side, whereas the latter accounts for the broadening at the high-energy side. The diffuse light scattering from the highly defective nucleation layer of GaN was found to produce a broad scattering background of the GaN TO mode. The methodology and conclusions of the present work could be applicable to Raman spectroscopic studies on other material interfaces.
Rapid and direct screening of H:C ratio in Archean kerogen via microRaman Spectroscopy
NASA Astrophysics Data System (ADS)
Ferralis, N.; Matys, E. D.; Allwood, A.; Knoll, A. H.; Summons, R. E.
2015-12-01
Rapid evaluation of the preservation of biosignatures in ancient kerogens is essential for the evaluation of the usability of Earth analogues as proxies of Martian geological materials. No single, non-destructive and non-invasive technique currently exists to rapidly determine such state of preservation of the organic matter in relation to its geological and mineral environment. Due to its non-invasive nature, microRaman spectroscopy is emerging as a candidate technique for the qualitative determination maturity of organic matter, by correlating Raman spectral features and aromatic carbon cluster size. Here we will present a novel quantitative method in which before-neglected Raman spectral features are correlated directly and with excellent accuracy with the H:C ratio. In addition to providing a chemical justification of the found direct correlation, we will show its applicability and predictive capabilities in evaluating H:C in Archean kerogens. This novel method opens new opportunities for the use of Raman spectroscopy and mapping. This includes the non-invasively determination of kerogen preservation and microscale chemical diversity within a particular Earth analogue, to be potentially extended to evaluate Raman spectra acquired directly on Mars.
A micro-Raman spectroscopic investigation of leukemic U-937 cells in aged cultures
NASA Astrophysics Data System (ADS)
Fazio, Enza; Trusso, Sebastiano; Franco, Domenico; Nicolò, Marco Sebastiano; Allegra, Alessandro; Neri, Fortunato; Musolino, Caterina; Guglielmino, Salvatore P. P.
2016-04-01
Recently it has been shown that micro-Raman spectroscopy combined with multivariate analysis is able to discriminate among different types of tissues and tumoral cells by the detection of significant alterations and/or reorganizations of complex biological molecules, such as nucleic acids, lipids and proteins. Moreover, its use, being in principle a non-invasive technique, appears an interesting clinical tool for the evaluation of the therapeutical effects and of the disease progression. In this work we analyzed molecular changes in aged cultures of leukemia model U937 cells with respect to fresh cultures of the same cell line. In fact, structural variations of individual neoplastic cells on aging may lead to a heterogeneous data set, therefore falsifying confidence intervals, increasing error levels of analysis and consequently limiting the use of Raman spectroscopy analysis. We found that the observed morphological changes of U937 cells corresponded to well defined modifications of the Raman contributions in selected spectral regions, where markers of specific functional groups, useful to characterize the cell state, are present. A detailed subcellular analysis showed a change in cellular organization as a function of time, and correlated to a significant increase of apoptosis levels. Besides the aforementioned study, Raman spectra were used as input for principal component analysis (PCA) in order to detect and classify spectral changes among U937 cells.
Pompidor, Guillaume; Dworkowski, Florian S. N.; Thominet, Vincent; Schulze-Briese, Clemens; Fuchs, Martin R.
2013-01-01
The combination of X-ray diffraction experiments with optical methods such as Raman, UV/Vis absorption and fluorescence spectroscopy greatly enhances and complements the specificity of the obtained information. The upgraded version of the in situ on-axis micro-spectrophotometer, MS2, at the macromolecular crystallography beamline X10SA of the Swiss Light Source is presented. The instrument newly supports Raman and resonance Raman spectroscopy, in addition to the previously available UV/Vis absorption and fluorescence modes. With the recent upgrades of the spectral bandwidth, instrument stability, detection efficiency and control software, the application range of the instrument and its ease of operation were greatly improved. Its on-axis geometry with collinear X-ray and optical axes to ensure optimal control of the overlap of sample volumes probed by each technique is still unique amongst comparable facilities worldwide and the instrument has now been in general user operation for over two years. PMID:23955041
Pompidor, Guillaume; Dworkowski, Florian S N; Thominet, Vincent; Schulze-Briese, Clemens; Fuchs, Martin R
2013-09-01
The combination of X-ray diffraction experiments with optical methods such as Raman, UV/Vis absorption and fluorescence spectroscopy greatly enhances and complements the specificity of the obtained information. The upgraded version of the in situ on-axis micro-spectrophotometer, MS2, at the macromolecular crystallography beamline X10SA of the Swiss Light Source is presented. The instrument newly supports Raman and resonance Raman spectroscopy, in addition to the previously available UV/Vis absorption and fluorescence modes. With the recent upgrades of the spectral bandwidth, instrument stability, detection efficiency and control software, the application range of the instrument and its ease of operation were greatly improved. Its on-axis geometry with collinear X-ray and optical axes to ensure optimal control of the overlap of sample volumes probed by each technique is still unique amongst comparable facilities worldwide and the instrument has now been in general user operation for over two years.
Schechinger, Monika; Marks, Haley; Locke, Andrea; Choudhury, Mahua; Cote, Gerard
2018-01-01
DNA-functionalized nanoparticles, when paired with surface-enhanced Raman spectroscopy (SERS), can rapidly detect microRNA. However, widespread use of this approach is hindered by drawbacks associated with large and expensive benchtop Raman microscopes. MicroRNA-17 (miRNA-17) has emerged as a potential epigenetic indicator of preeclampsia, a condition that occurs during pregnancy. Biomarker detection using an SERS point-of-care device could enable prompt diagnosis and prevention as early as the first trimester. Recently, strides have been made in developing portable Raman systems for field applications. An SERS assay for miRNA-17 was assessed and translated from traditional benchtop Raman microscopes to a handheld system. Three different photoactive molecules were compared as potential Raman reporter molecules: a chromophore, malachite green isothiocyanate (MGITC), a fluorophore, tetramethylrhodamine isothiocyanate, and a polarizable small molecule 5,5-dithio-bis-(2-nitrobenzoic acid) (DTNB). For the benchtop Raman microscope, the DTNB-labeled assay yielded the greatest sensitivity under 532-nm laser excitation, but the MGITC-labeled assay prevailed at 785 nm. Conversely, DTNB was preferable for the miniaturized 785-nm Raman system. This comparison showed significant SERS enhancement variation in response to 1-nM miRNA-17, implying that the sensitivity of the assay may be more heavily dependent on the excitation wavelength, instrumentation, and Raman reporter chosen than on the plasmonic coupling from DNA/miRNA-mediated nanoparticle assemblies. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).
Viability of 3h grown bacterial micro-colonies after direct Raman identification.
Mathey, R; Dupoy, M; Espagnon, I; Leroux, D; Mallard, F; Novelli-Rousseau, A
2015-02-01
Clinical diagnostics in routine microbiology still mostly relies on bacterial growth, a time-consuming process that prevents test results to be used directly as key decision-making elements for therapeutic decisions. There is some evidence that Raman micro-spectroscopy provides clinically relevant information from a limited amount of bacterial cells, thus holding the promise of reduced growth times and accelerated result delivery. Indeed, bacterial identification at the species level directly from micro-colonies at an early time of growth (6h) directly on their growth medium has been demonstrated. However, such analysis is suspected to be partly destructive and could prevent the further growth of the colony needed for other tests, e.g. antibiotic susceptibility testing (AST). In the present study, we evaluated the effect of the powerful laser excitation used for Raman identification on micro-colonies probed after very short growth times. We show here, using envelope integrity markers (Syto 9 and Propidium Iodide) directly on ultra-small micro-colonies of a few tens of Escherichia coli and Staphylococcus epidermidis cells (3h growth time), that only the cells that are directly impacted by the laser lose their membrane integrity. Growth kinetics experiments show that the non-probed surrounding cells are sometimes also affected but that the micro-colonies keep their ability to grow, resulting in normal aspect and size of colonies after 15h of growth. Thus, Raman spectroscopy could be used for very early (<3h) identification of grown micro-organisms without impairing further antibiotics susceptibility characterization steps. Copyright © 2014 Elsevier B.V. All rights reserved.
He, Qiu-ju; Wang, Li-qin
2016-02-01
As the birthplace of Silk Road, China has a long dyeing history. The valuable information about the production time, the source of dyeing material, dyeing process and preservation status were existed in organic dyestuff deriving from cultural relics and artifacts. However, because of the low contents, complex compositions and easily degraded of dyestuff, it is always a challenging task to identify the dyestuff in relics analyzing field. As a finger-print spectrum, Raman spectroscopy owns unique superiorities in dyestuff identification. Thus, the principle, characteristic, limitation, progress and development direction of micro-Raman spectroscopy (MRS/µ-Raman), near infrared reflection and Fourier transform Raman spectroscopy (NIR-FT-Raman), surface-enhanced Raman spectroscopy (SERS) and resonance raman spectroscopy (RRS) have been introduced in this paper. Furthermore, the features of Raman spectra of gardenia, curcumin and other natural dyestuffs were classified by MRS technology, and then the fluorescence phenomena of purpurin excitated with different wavelength laser was compared and analyzed. At last, gray green silver colloidal particles were made as the base, then the colorant of madder was identified combining with thin layer chromatography (TLC) separation technology and SERS, the result showed that the surface enhancement effect of silver colloidal particles could significantly reduce fluorescence background of the Raman spectra. It is pointed out that Raman spectroscopy is a rapid and convenient molecular structure qualitative methodology, which has broad application prospect in dyestuff analysis of cultural relics and artifacts. We propose that the combination of multi-Raman spectroscopy, separation technology and long distance transmission technology are the development trends of Raman spectroscopy.
Innovative smart micro sensors for Army weaponry applications
NASA Astrophysics Data System (ADS)
Ruffin, Paul B.; Brantley, Christina; Edwards, Eugene
2008-03-01
Micro sensors offer the potential solution to cost, size, and weight issues associated with smart networked sensor systems designed for environmental/missile health monitoring and rocket out-gassing/fuel leak detection, as well as situational awareness on the battlefield. In collaboration with the University of Arkansas (Fayetteville), University of Alabama (Tuscaloosa and Birmingham), Alabama A&M University (Normal), and Streamline Automation (Huntsville, AL), scientists and engineers at the Army Aviation & Missile Research, Development, and Engineering Center (AMRDEC) are investigating several nano-based technologies to solve the problem of sensing extremely small levels of toxic gases associated with both chemical warfare agents (in air and liquids) and potential rocket motor leaks. Innovative techniques are being devised to adapt voltammetry, which is a well established technique for the detection and quantification of substances dissolved in liquids, to low-cost micro sensors for detecting airborne chemical agents and potential missile propellant leakages. In addition, a surface enhanced Raman scattering (SERS) technique, which enhances Raman scattered light by excitation of surface plasmons on nanoporous metal surfaces (nanospheres), is being investigated to develop novel smart sensors for the detection of chemical agents (including rocket motor out-gassing) and potential detection of home-made explosive devices. In this paper, results are delineated that are associated with experimental studies, which are conducted for the aforementioned cases and for several other nano-based technology approaches. The design challenges of each micro sensor technology approach are discussed. Finally, a comparative analysis of the various innovative micro-sensor techniques is provided.
Colle, Jean-Yves; Naji, Mohamed; Sierig, Mark; Manara, Dario
2017-01-01
A novel approach for the Raman measurement of nuclear materials is reported in this paper. It consists of the enclosure of the radioactive sample in a tight capsule that isolates the material from the atmosphere. The capsule can optionally be filled with a chosen gas pressurized up to 20 bars. The micro-Raman measurement is performed through an optical-grade quartz window. This technique permits accurate Raman measurements with no need for the spectrometer to be enclosed in an alpha-tight containment. It therefore allows the use of all options of the Raman spectrometer, like multi-wavelength laser excitation, different polarizations, and single or triple spectrometer modes. Some examples of measurements are shown and discussed. First, some spectral features of a highly radioactive americium oxide sample (AmO2) are presented. Then, we report the Raman spectra of neptunium oxide (NpO2) samples, the interpretation of which is greatly improved by employing three different excitation wavelengths, 17O doping, and a triple mode configuration to measure the anti-stokes Raman lines. This last feature also allows the estimation of the sample surface temperature. Finally, data that were measured on a sample from Chernobyl lava, where phases are identified by Raman mapping, are shown. PMID:28448046
Applications of Raman spectroscopy to gemology.
Bersani, Danilo; Lottici, Pier Paolo
2010-08-01
Being nondestructive and requiring short measurement times, a low amount of material, and no sample preparation, Raman spectroscopy is used for routine investigation in the study of gemstone inclusions and treatments and for the characterization of mounted gems. In this work, a review of the use of laboratory Raman and micro-Raman spectrometers and of portable Raman systems in the gemology field is given, focusing on gem identification and on the evaluation of the composition, provenance, and genesis of gems. Many examples are shown of the use of Raman spectroscopy as a tool for the identification of imitations, synthetic gems, and enhancement treatments in natural gemstones. Some recent developments are described, with particular attention being given to the semiprecious stone jade and to two important organic materials used in jewelry, i.e., pearls and corals.
NASA Astrophysics Data System (ADS)
Rathnayake, R. M. N. M.; Mantilaka, M. M. M. G. P. G.; Hara, Masanori; Huang, Hsin-Hui; Wijayasinghe, H. W. M. A. C.; Yoshimura, Masamichi; Pitawala, H. M. T. G. A.
2017-07-01
Solid polymer composite systems are widely being used for potential technological applications in secondary energy sources and electrochromic devices. In this study, we synthesized and characterized a composite material composed of polyaniline (PANI) and natural needle platy (NPG) vein graphite. Fourier transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), cyclic voltammetry (CV), scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), micro-Raman analysis, thermogravimetric and differential thermal analysis (TGA/DTA), transmission electron microscopy (TEM) were used to study the structural and electrochemical properties of the prepared PANI/NPG graphite composite. XPS, FTIR, and micro-Raman analysis confirmed the existence of relevant functional groups and bonding in the prepared PANI/NPG composite material. The composite shows a very low corrosion rate, approximately 29 μm per year, and high hydrophobicity on steel surfaces, which helps to prevent the corrosion due to O2 penetration towards the metal surface. It indicates that the composite can be used as a high potential surface coating material to anticorrosion. The specific capacitance of PANI/NPG composite is 833.3 F g-1, which is higher than that of PANI. This synergistic electrical performance result proves the prepared PANI/NPG graphite composite as a suitable protective coating material for steel surfaces.
Guerra, I; Cardell, C
2015-10-01
The novel Structural Chemical Analyser (hyphenated Raman spectroscopy and scanning electron microscopy equipped with an X-ray detector) is gaining popularity since it allows 3-D morphological studies and elemental, molecular, structural and electronic analyses of a single complex micro-sized sample without transfer between instruments. However, its full potential remains unexploited in painting heritage where simultaneous identification of inorganic and organic materials in paintings is critically yet unresolved. Despite benefits and drawbacks shown in literature, new challenges have to be faced analysing multifaceted paint specimens. SEM-Structural Chemical Analyser systems differ since they are fabricated ad hoc by request. As configuration influences the procedure to optimize analyses, likewise analytical protocols have to be designed ad hoc. This paper deals with the optimization of the analytical procedure of a Variable Pressure Field Emission scanning electron microscopy equipped with an X-ray detector Raman spectroscopy system to analyse historical paint samples. We address essential parameters, technical challenges and limitations raised from analysing paint stratigraphies, archaeological samples and loose pigments. We show that accurate data interpretation requires comprehensive knowledge of factors affecting Raman spectra. We tackled: (i) the in-FESEM-Raman spectroscopy analytical sequence, (ii) correlations between FESEM and Structural Chemical Analyser/laser analytical position, (iii) Raman signal intensity under different VP-FESEM vacuum modes, (iv) carbon deposition on samples under FESEM low-vacuum mode, (v) crystal nature and morphology, (vi) depth of focus and (vii) surface-enhanced Raman scattering effect. We recommend careful planning of analysis strategies prior to research which, although time consuming, guarantees reliable results. The ultimate goal of this paper is to help to guide future users of a FESEM-Structural Chemical Analyser system in order to increase applications. © 2015 The Authors Journal of Microscopy © 2015 Royal Microscopical Society.
Investigation on Clarified Fruit Juice Composition by Using Visible Light Micro-Raman Spectroscopy.
Camerlingo, Carlo; Zenone, Flora; Delfino, Ines; Diano, Nadia; Mita, Damiano Gustavo; Lepore, Maria
2007-10-03
Liquid samples of clarified apple and apricot juices at different productionstages were investigated using visible light micro-Raman spectroscopy in order to assessits potential in monitoring fruit juice production. As is well-known, pectin plays a strategicrole in the production of clarified juice and the possibility of using Raman for its detectionduring production was therefore evaluated. The data analysis has enabled the clearidentification of pectin. In particular, Raman spectra of apple juice samples from washedand crushed fruits revealed a peak at 845 cm -1 (typical of pectin) which disappears in theRaman spectra of depectinised samples. The fructose content was also revealed by thepresence of four peaks at 823 cm -1 , 872 cm -1 , 918 cm -1 and 975 cm -1 . In the case of apricotjuice, several Raman fingerprints of β-carotene at 1008, 1159 and 1520 cm -1 were alsohighlighted. Present results resulted interesting for the exclusive use of optical methods forthe quantitative determination of the above-mentioned substances in place of thebiochemical assays generally used for this purpose, which are time consuming and requiredifferent chemical reagents for each of them.
Ghosal, Sutapa; Wagner, Jeff
2013-07-07
We present correlated application of two micro-analytical techniques: scanning electron microscopy/energy dispersive X-ray spectroscopy (SEM/EDS) and Raman micro-spectroscopy (RMS) for the non-invasive characterization and molecular identification of flame retardants (FRs) in environmental dusts and consumer products. The SEM/EDS-RMS technique offers correlated, morphological, molecular, spatial distribution and semi-quantitative elemental concentration information at the individual particle level with micrometer spatial resolution and minimal sample preparation. The presented methodology uses SEM/EDS analyses for rapid detection of particles containing FR specific elements as potential indicators of FR presence in a sample followed by correlated RMS analyses of the same particles for characterization of the FR sub-regions and surrounding matrices. The spatially resolved characterization enabled by this approach provides insights into the distributional heterogeneity as well as potential transfer and exposure mechanisms for FRs in the environment that is typically not available through traditional FR analysis. We have used this methodology to reveal a heterogeneous distribution of highly concentrated deca-BDE particles in environmental dust, sometimes in association with identifiable consumer materials. The observed coexistence of deca-BDE with consumer material in dust is strongly indicative of its release into the environment via weathering/abrasion of consumer products. Ingestion of such enriched FR particles in dust represents a potential for instantaneous exposure to high FR concentrations. Therefore, correlated SEM/RMS analysis offers a novel investigative tool for addressing an area of important environmental concern.
Chernenko, Tatyana; Buyukozturk, Fulden; Miljkovic, Milos; Carrier, Rebecca; Diem, Max; Amiji, Mansoor
2013-01-01
Active targeted delivery of nanoparticle-encapsulated agents to tumor cells in vivo is expected to enhance therapeutic effect with significantly less non-specific toxicity. Active targeting is based on surface modification of nanoparticles with ligands that bind with extracellular targets and enhance payload delivery in the cells. In this study, we have used label-free Raman micro-spectral analysis and kinetic modeling to study cellular interactions and intracellular delivery of C6-ceramide using a non-targeted and an epidermal growth factor receptor (EGFR) targeted biodegradable polymeric nano-delivery systems, in EGFR-expressing human ovarian adenocarcinoma (SKOV3) cells. The results show that EGFR peptide-modified nanoparticles were rapidly internalized in SKOV3 cells leading to significant intracellular accumulation as compared to non-specific uptake by the non-targeted nanoparticles. Raman micro-spectral analysis enables visualization and quantification of the carrier system, drug-load, and responses of the biological systems interrogated, without exogenous staining and labeling procedures. PMID:24298430
NASA Astrophysics Data System (ADS)
Ishimaru, Yasumitsu; Oshima, Yusuke; Imai, Yuuki; Iimura, Tadahiro; Takanezawa, Sota; Hino, Kazunori; Miura, Hiromasa
2018-02-01
To detect the bone quality loss in osteoporosis, we performed Raman spectroscopic analysis of sciatic nerve resection (NX) mice. Eight months after surgery, lower limbs were collected from the mice and fixed with 70% ethanol. Raman spectra of anterior cortical surface of the proximal tibia at 5 points in each bone were measured by RENISHAW inVia Raman Microscope. Excitation wave length was 785 nm. We also performed DXA and micro CT measurement to confirm the bone mineral density and bone microstructure in the osteoporotic model induced by sciatic nerve resection. In the result of Raman spectroscopy, we detected changes of Raman peak intensity ratio in carbonate/phosphate, mineral/combined proline and hydroxyproline and mineral/phenylalanine. In addition, in the result of micro CT, we found significant changes in VOX BV/TV, Trabecular number, thickness, cancellous bone mineral density, cortical thickness and cortical bone mineral density. The results suggest that not only the bone mineral density but also bone quality reduced in the NX mice. We conclude that Raman spectroscopy is a useful for bone quality assessment as a complementary technique for conventional diagnostics.
NASA Astrophysics Data System (ADS)
Noguchi, Naoki; Kubo, Tomoaki; Durham, William B.; Kagi, Hiroyuki; Shimizu, Ichiko
2016-08-01
We have developed a high-resolution technique based on micro Raman spectroscopy to measure hydrogen isotope diffusion profiles in ice Ih. The calibration curve for quantitative analysis of deuterium in ice Ih was constructed using micro Raman spectroscopy. Diffusion experiments using diffusion couples composed of dense polycrystalline H2O and D2O ice were carried out under a gas confining pressure of 100 MPa (to suppress micro-fracturing and pore formation) at temperatures from 235 K to 245 K and diffusion times from 0.2 to 94 hours. Two-dimensional deuterium profiles across the diffusion couples were determined by Raman imaging. The location of small spots of frost from room air could be detected from the shapes of the Raman bands of OH and OD stretching modes, which change because of the effect of the molar ratio of deuterium on the molecular coupling interaction. We emphasize the validity for screening the impurities utilizing the coupling interaction. Some recrystallization and grain boundary migration occurred in recovered diffusion couples, but analysis of two-dimensional diffusion profiles of regions not affected by grain boundary migration allowed us to measure a volume diffusivity for ice at 100 MPa of (2.8 ± 0.4) ×10-3exp[ -57.0 ± 15.4kJ /mol RT ] m2 /s (R is the gas constant, T is temperature). Based on ambient pressure diffusivity measurements by others, this value indicates a high (negative) activation volume for volume diffusivity of -29.5 cm3/mol or more. We can also constrain the value of grain boundary diffusivity in ice at 100 MPa to be <104 that of volume diffusivity.
Wang, Junping; Xie, Xinfang; Feng, Jinsong; Chen, Jessica C; Du, Xin-jun; Luo, Jiangzhao; Lu, Xiaonan; Wang, Shuo
2015-07-02
Listeria monocytogenes is a facultatively anaerobic, Gram-positive, rod-shape foodborne bacterium causing invasive infection, listeriosis, in susceptible populations. Rapid and high-throughput detection of this pathogen in dairy products is critical as milk and other dairy products have been implicated as food vehicles in several outbreaks. Here we evaluated confocal micro-Raman spectroscopy (785 nm laser) coupled with chemometric analysis to distinguish six closely related Listeria species, including L. monocytogenes, in both liquid media and milk. Raman spectra of different Listeria species and other bacteria (i.e., Staphylococcus aureus, Salmonella enterica and Escherichia coli) were collected to create two independent databases for detection in media and milk, respectively. Unsupervised chemometric models including principal component analysis and hierarchical cluster analysis were applied to differentiate L. monocytogenes from Listeria and other bacteria. To further evaluate the performance and reliability of unsupervised chemometric analyses, supervised chemometrics were performed, including two discriminant analyses (DA) and soft independent modeling of class analogies (SIMCA). By analyzing Raman spectra via two DA-based chemometric models, average identification accuracies of 97.78% and 98.33% for L. monocytogenes in media, and 95.28% and 96.11% in milk were obtained, respectively. SIMCA analysis also resulted in satisfied average classification accuracies (over 93% in both media and milk). This Raman spectroscopic-based detection of L. monocytogenes in media and milk can be finished within a few hours and requires no extensive sample preparation. Copyright © 2015 Elsevier B.V. All rights reserved.
Lausch, V; Hermann, P; Laue, M; Bannert, N
2014-06-01
Successive application of negative staining transmission electron microscopy (TEM) and tip-enhanced Raman spectroscopy (TERS) is a new correlative approach that could be used to rapidly and specifically detect and identify single pathogens including bioterrorism-relevant viruses in complex samples. Our objective is to evaluate the TERS-compatibility of commonly used electron microscopy (EM) grids (sample supports), chemicals and negative staining techniques and, if required, to devise appropriate alternatives. While phosphortungstic acid (PTA) is suitable as a heavy metal stain, uranyl acetate, paraformaldehyde in HEPES buffer and alcian blue are unsuitable due to their relatively high Raman scattering. Moreover, the low thermal stability of the carbon-coated pioloform film on copper grids (pioloform grids) negates their utilization. The silicon in the cantilever of the silver-coated atomic force microscope tip used to record TERS spectra suggested that Si-based grids might be employed as alternatives. From all evaluated Si-based TEM grids, the silicon nitride (SiN) grid was found to be best suited, with almost no background Raman signals in the relevant spectral range, a low surface roughness and good particle adhesion properties that could be further improved by glow discharge. Charged SiN grids have excellent particle adhesion properties. The use of these grids in combination with PTA for contrast in the TEM is suitable for subsequent analysis by TERS. The study reports fundamental modifications and optimizations of the negative staining EM method that allows a combination with near-field Raman spectroscopy to acquire a spectroscopic signature from nanoscale biological structures. This should facilitate a more precise diagnosis of single viral particles and other micro-organisms previously localized and visualized in the TEM. © 2014 The Society for Applied Microbiology.
Ion beam modification of zinc white pigment characterized by ex situ and in situ μ-Raman and XPS
NASA Astrophysics Data System (ADS)
Beck, L.; Gutiérrez, P. C.; Miro, S.; Miserque, F.
2017-10-01
Zinc oxide, known as zinc white, is one of the principal white pigments developed in the 18th century and was used by the Impressionist painters. ZnO as artists' pigment has occasionally been characterized by X-ray and ion beam techniques, but these studies are limited by the potential for visible radiation effect. Ion beam modifications of zinc oxide have extensively been investigated, but mainly for electronic and industrial applications. In this paper, we focus our investigation on ion beam modification of ZnO used as pigment. Two irradiation conditions have been used: an external 3 MeV proton micro-beam representative of PIXE analysis and 2 MeV H+ and 1.2 MeV Au + beams in vacuum to investigate irradiation modifications in electronic and nuclear energy loss regimes. Ion beam modification was characterized by ex situ and in situ micro-Raman spectrometry and XPS. The results shows that IBA of zinc white can be carried out safely in historical paintings with low current and dose.
Micro-Raman spectroscopy for meat type detection
NASA Astrophysics Data System (ADS)
De Biasio, M.; Stampfer, P.; Leitner, R.; Huck, C. W.; Wiedemair, V.; Balthasar, D.
2015-06-01
The recent horse meat scandal in Europe increased the demand for optical sensors that can identify meat type. Micro-Raman spectroscopy is a promising technique for the discrimination of meat types. Here, we present micro-Raman measurements of chicken, pork, turkey, mutton, beef and horse meat test samples. The data was analyzed with different combinations of data normalization and classification approaches. Our results show that Raman spectroscopy can discriminate between different meat types. Red and white meat are easily discriminated, however a sophisticated chemometric model is required to discriminate species within these groups.
NASA Astrophysics Data System (ADS)
Jacobs, P. Js; Cnudde, V.
2003-04-01
X-ray computed micro-tomography (μCT) is a promising non-destructive imaging technique to study building materials. μCT analysis provides information on the internal structure and petrophysical properties of small samples (size up to 2 cm diameter and 6 cm height), with to date a maximum resolution of 10 μm for commercial systems (Skyscan 1072). μCT allows visualising and measuring complete three-dimensional object structures without sample preparation. Possible applications of the μCT-technique for the monitoring of natural building stones are multiple: (i) to determine non-destructively porosity based on 3D images, (ii) to visualise weathering phenomena at the μ-scale, (iii) to understand the rationale of weathering processes, (iv) to visualise the presence of waterrepellents and consolidation products, (v) to monitor the protective effects of these products during weathering in order to understand the underlying weathering mechanisms and (vi) to provide advise on the suitability of products for the treatment of a particular rock-type. μCT-technique in combination with micro-Raman spectroscopy could prove to be a powerful tool for the future, as the combination of 3D visualisation and 2D chemical determination of inorganic as well as organic components could provide new insights to optimise conservation and restoration techniques of building materials. Determining the penetration depth of restoration products, used to consolidate or to protect natural building stones from weathering, is crucial if the application of conservation products is planned. Every type of natural building stone has its own petrophysical characteristics and each rock type reacts differently on the various restoration products available on the market. To assess the penetration depth and the effectiveness of a certain restoration product, μCT technology in combination with micro-Raman spectroscopy could be applied. Due to its non-destructive character and its resolution down to porosity scale, the technology of μCT offers a large potential of application. μCT-technique in combination with micro-Raman spectroscopy could prove to be a powerful tool for the future, as the combination of 3D visualisation and 2D chemical determination could provide new insights to optimise conservation and restoration techniques of building materials. These principles will be demonstrated for Maastricht limestone and Bray sandstone that have been selected for this study because of their high porosity and their very pure composition.
de Campos, Richard Piffer Soares; Yoshida, Inez Valeria Pagotto; Breitkreitz, Márcia Cristina; Poppi, Ronei Jesus; Fracassi da Silva, José Alberto
2013-01-01
Methacryloxypropyl-modified poly(dimethylsiloxane) rubbers were obtained from poly(dimethylsiloxane), PDMS, and methacryloxypropyltrimethoxysilane, MPTMS, by polycondensation reactions. The modified rubbers, prepared with 20 and 30% (v/v) of MPTMS, were used as substrates for microchannel fabrication by the CO(2) laser ablation technique. Raman imaging spectroscopy was used for the surface characterization, showing the homogeneity of the rubbery material, with uniform distribution of the crosslinking centers. Under the experimental conditions used, damage to the rubber from the CO(2) laser radiation used for the channel engraving was not observed. Correlation maps of the surface were obtained in order to spatially evaluate the modification inside and outside the channels. The correlations between the methacryloxypropyl-modified poly(dimethylsiloxane) rubbers and MPTMS (spectral range of 1800-1550 cm(-1)) and PDMS (spectral range of 820-670 cm(-1)) precursors were higher than 0.95 and 0.99, respectively. In addition, Raman imaging spectroscopy allows monitoring the topography of the fabricated microchannel. Copyright © 2012 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shur, V. Ya., E-mail: vladimir.shur@urfu.ru; Zelenovskiy, P. S.
2014-08-14
The application of the most effective methods of the domain visualization in model uniaxial ferroelectrics of lithium niobate (LN) and lithium tantalate (LT) family, and relaxor strontium-barium niobate (SBN) have been reviewed in this paper. We have demonstrated the synergetic effect of joint usage of optical, confocal Raman, and piezoelectric force microscopies which provide extracting of the unique information about formation of the micro- and nanodomain structures. The methods have been applied for investigation of various types of domain structures with increasing complexity: (1) periodical domain structure in LN and LT, (2) nanodomain structures in LN, LT, and SBN, (3)more » nanodomain structures in LN with modified surface layer, (4) dendrite domain structure in LN. The self-assembled appearance of quasi-regular nanodomain structures in highly non-equilibrium switching conditions has been considered.« less
Raman spectroscopy differentiates between sensitive and resistant multiple myeloma cell lines
NASA Astrophysics Data System (ADS)
Franco, Domenico; Trusso, Sebastiano; Fazio, Enza; Allegra, Alessandro; Musolino, Caterina; Speciale, Antonio; Cimino, Francesco; Saija, Antonella; Neri, Fortunato; Nicolò, Marco S.; Guglielmino, Salvatore P. P.
2017-12-01
Current methods for identifying neoplastic cells and discerning them from their normal counterparts are often nonspecific and biologically perturbing. Here, we show that single-cell micro-Raman spectroscopy can be used to discriminate between resistant and sensitive multiple myeloma cell lines based on their highly reproducible biomolecular spectral signatures. In order to demonstrate robustness of the proposed approach, we used two different cell lines of multiple myeloma, namely MM.1S and U266B1, and their counterparts MM.1R and U266/BTZ-R subtypes, resistant to dexamethasone and bortezomib, respectively. Then, micro-Raman spectroscopy provides an easily accurate and noninvasive method for cancer detection for both research and clinical environments. Characteristic peaks, mostly due to different DNA/RNA ratio, nucleic acids, lipids and protein concentrations, allow for discerning the sensitive and resistant subtypes. We also explored principal component analysis (PCA) for resistant cell identification and classification. Sensitive and resistant cells form distinct clusters that can be defined using just two principal components. The identification of drug-resistant cells by confocal micro-Raman spectroscopy is thus proposed as a clinical tool to assess the development of resistance to glucocorticoids and proteasome inhibitors in myeloma cells.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Geng, Yijia; Xu, Shuping; Xu, Weiqing, E-mail: xuwq@jlu.edu.cn
An integrated and portable Raman analyzer featuring an inverted probe fixed on a motor-driving adjustable optical module was designed for the combination of a microfluidic system. It possesses a micro-imaging function. The inverted configuration is advantageous to locate and focus microfluidic channels. Different from commercial micro-imaging Raman spectrometers using manual switchable light path, this analyzer adopts a dichroic beam splitter for both imaging and signal collection light paths, which avoids movable parts and improves the integration and stability of optics. Combined with surface-enhanced Raman scattering technique, this portable Raman micro-analyzer is promising as a powerful tool for microfluidic analytics.
Oßmann, Barbara E; Sarau, George; Schmitt, Sebastian W; Holtmannspötter, Heinrich; Christiansen, Silke H; Dicke, Wilhelm
2017-06-01
When analysing microplastics in food, due to toxicological reasons it is important to achieve clear identification of particles down to a size of at least 1 μm. One reliable, optical analytical technique allowing this is micro-Raman spectroscopy. After isolation of particles via filtration, analysis is typically performed directly on the filter surface. In order to obtain high qualitative Raman spectra, the material of the membrane filters should not show any interference in terms of background and Raman signals during spectrum acquisition. To facilitate the usage of automatic particle detection, membrane filters should also show specific optical properties. In this work, beside eight different, commercially available membrane filters, three newly designed metal-coated polycarbonate membrane filters were tested to fulfil these requirements. We found that aluminium-coated polycarbonate membrane filters had ideal characteristics as a substrate for micro-Raman spectroscopy. Its spectrum shows no or minimal interference with particle spectra, depending on the laser wavelength. Furthermore, automatic particle detection can be applied when analysing the filter surface under dark-field illumination. With this new membrane filter, analytics free of interference of microplastics down to a size of 1 μm becomes possible. Thus, an important size class of these contaminants can now be visualized and spectrally identified. Graphical abstract A newly developed aluminium coated polycarbonate membrane filter enables automatic particle detection and generation of high qualitative Raman spectra allowing identification of small microplastics.
Micro-Raman spectroscopy on oral tissues
NASA Astrophysics Data System (ADS)
Zenone, F.; Lepore, M.; Perna, G.; Carmone, P.; Riccio, R.; Gaeta, G. M.; Capozzi, V.
2006-02-01
Micro-Raman Spectroscopy (μ-RS) provides a unique tool in medicine for a not invasive and real time analysis of biological tissue for biopsy and "in vivo" investigation. Based on the evaluation of molecular vibration frequencies, the μ-RS is able to detect the main molecular bonds of protein constituents, as the C-H and C-C ones. Changes in frequency or in the relative intensity of the vibration modes revealed by μ-RS can be related to changes of chemical bond and of protein structure induced by pathology. The μ-RS has been performed on samples of oral tissue from informed patients, affected by pemphigus vulgaris (an oral pathology) in an advanced regression state. The biopsies were thin slices (about 1mm thick) with 6mm diameter. The sample was measured through a 170 μm thick cover-glass. The experimental set-up was mainly composed by a He-Ne laser and a monochromator equipped with a Peltier cell and with a grating of 1800 grooves/mm. The laser light was focused on the sample surface by means of a long focal length 50X optical objective. The main protein bonds are clearly detectable in the considered samples and this give important information on the integrity and on the state of tissue components (lipids and proteins), and consequently on the occurrence of pathology. The potential application of this method for in vivo analysis is an invaluable alternative to biopsy and pathological examinations for many medical application as screening diagnostic, therapy progress examination, and surgical support.
Micro-Raman spectroscopy of natural and synthetic indigo samples.
Vandenabeele, Peter; Moens, Luc
2003-02-01
In this work indigo samples from three different sources are studied by using Raman spectroscopy: the synthetic pigment and pigments from the woad (Isatis tinctoria) and the indigo plant (Indigofera tinctoria). 21 samples were obtained from 8 suppliers; for each sample 5 Raman spectra were recorded and used for further chemometrical analysis. Principal components analysis (PCA) was performed as data reduction method before applying hierarchical cluster analysis. Linear discriminant analysis (LDA) was implemented as a non-hierarchical supervised pattern recognition method to build a classification model. In order to avoid broad-shaped interferences from the fluorescence background, the influence of 1st and 2nd derivatives on the classification was studied by using cross-validation. Although chemically identical, it is shown that Raman spectroscopy in combination with suitable chemometric methods has the potential to discriminate between synthetic and natural indigo samples.
NASA Astrophysics Data System (ADS)
Sharma, S. K.; Kamemoto, L. E.; Misra, A. K.; Goodman, M. T.; Luk, H. W.; Killeen, J. L.
2010-04-01
We present results of in vitro micro-Raman spectroscopy of normal and cancerous cervical and ovarian tissues excited with 785 nm near-infrared (NIR) laser. Micro- Raman spectra of squamous cervical cells of both cervix and ovarian tissues show significant differences in the spectra of normal and cancerous cells. In particular, several well-defined Raman peaks in the 775-975 cm-1 region are observed in the spectra of normal cervix squamous cells but are completely missing in the spectra of invasive cervical cancer cells. In the high-frequency 2800-3100 cm-1 region it is shown that the peak area under CH stretching band is much lower than the corresponding area in the spectra of normal cells. In the case of ovarian tissues, the micro-Raman spectra show noticeable spectral differences between normal cells and ovarian serous cancer cells. In particular, we observed the accumulation of β-carotene in ovarian serous cancer cells compared to normal ovarian cells from women with no ovarian cancer. The NIR micro-Raman spectroscopy offers a potential molecular technique for detecting cervical and ovarian cancer from the respective tissues.
Detection of Leukemia with Blood Samples Using Raman Spectroscopy and Multivariate Analysis
NASA Astrophysics Data System (ADS)
Martínez-Espinosa, J. C.; González-Solís, J. L.; Frausto-Reyes, C.; Miranda-Beltrán, M. L.; Soria-Fregoso, C.; Medina-Valtierra, J.
2009-06-01
The use of Raman spectroscopy to analyze blood biochemistry and hence distinguish between normal and abnormal blood was investigated. Blood samples were obtained from 6 patients who were clinically diagnosed with leukemia and 6 healthy volunteers. The imprint was put under the microscope and several points were chosen for Raman measurement. All the spectra were collected by a confocal Raman micro-spectroscopy (Renishaw) with a NIR 830 nm laser. It is shown that the serum samples from patients with leukemia and from the control group can be discriminated when the multivariate statistical methods of principal component analysis (PCA) and linear discriminated analysis (LDA) are applied to their Raman spectra. The ratios of some band intensities were analyzed and some band ratios were significant and corresponded to proteins, phospholipids, and polysaccharides. The preliminary results suggest that Raman Spectroscopy could be a new technique to study the degree of damage to the bone marrow using just blood samples instead of biopsies, treatment very painful for patients.
NASA Astrophysics Data System (ADS)
Samek, O.; Haroniková, A.; Ježek, J.; Bernatová, S.; Márová, I.; Breierová, E.; Šerý, M.; Šiler, M.; Zemánek, P.
2016-12-01
A biomass of yeast strains has been studied using Raman spectroscopy due to their potential applications in the field of biofuel generation, food industry and biotechnological applications. In order to utilize biomass for efficient industrial/biotechnological production, the optimal cultivation parameters have to be determined which in turn lead to high production of desired substances such as oil, carotenoids, and pigments in the selected cell line of yeast. Therefore, we focused on different cultivation conditions (the effects of temperature regime and medium composition) and their influence on microorganisms growth and metabolic changes.
Stress Analysis of SiC MEMS Using Raman Spectroscopy
NASA Astrophysics Data System (ADS)
Ness, Stanley J.; Marciniak, M. A.; Lott, J. A.; Starman, L. A.; Busbee, J. D.; Melzak, J. M.
2003-03-01
During the fabrication of Micro-Electro-Mechanical Systems (MEMS), residual stress is often induced in the thin films that are deposited to create these systems. These stresses can cause the device to fail due to buckling, curling, or fracture. Industry is looking for ways to characterize the stress during the deposition of thin films in order to reduce or eliminate device failure. Micro-Raman spectroscopy has been successfully used to characterize poly-Si MEMS devices made with the MUMPS® process. Raman spectroscopy was selected because it is nondestructive, fast and has the potential for in situ stress monitoring. This research attempts to use Raman spectroscopy to analyze the stress in SiC MEMS made with the MUSiC® process. Raman spectroscopy is performed on 1-2-micron-thick SiC thin films deposited on silicon, silicon nitride, and silicon oxide substrates. The most common poly-type of SiC found in thin film MEMS made with the MUSiC® process is 3C-SiC. Research also includes baseline spectra of 6H, 4H, and 15R poly-types of bulk SiC.
NASA Astrophysics Data System (ADS)
Rossi, Barbara; Giarola, Marco; Mariotto, Gino; Ambrosi, Emmanuele; Monaco, Hugo L.
2010-05-01
Protein SOUL is a new member of the recently discovered putative heme-binding protein family called SOUL/HEBP and, to date, no structural information exists for this protein. Here, micro-Raman spectroscopy is used to study the vibrational properties of single crystals obtained from recombinant protein SOUL by means of two different optimization routes. This spectroscopic approach offers the valuable advantage of the in-situ collection of experimental data from protein crystals, placed onto a hanging-drop plate, under the same conditions used to grow the crystals. By focusing on the regions of amides I and III bands, some secondary structure characteristic features have been recognized. Moreover, some side-chain marker bands were observed in the Raman spectra of SOUL crystals and the unambiguous assignment of these peaks inferred by comparing the experimental Raman spectra of pure amino acids and their Raman intensities computed using quantum chemical calculations. Our comparative analysis allows to get a deeper understanding of the side-chain environments and of the interactions involving these specific amino acids in the two different SOUL crystals.
NASA Astrophysics Data System (ADS)
Lawton, Penelope F.; Saunter, Christopher D.; Girkin, John M.
2014-03-01
Since their invention by Ashkin optical tweezers have demonstrated their ability and versatility as a non-invasive tool for micromanipulation. One of the most useful additions to the basic optical tweezers system is micro-Raman spectroscopy, which permits highly sensitive analysis of single cells or particles. We report on the development of a dual laser system combining two spatial light modulators to holographically manipulate multiple traps (at 1064nm) whilst undertaking Raman spectroscopy using a 532nm laser. We can thus simultaneously trap multiple particles and record their Raman spectra, without perturbing the trapping system. The dual beam system is built around micro-fluidic channels where crystallisation of calcium carbonate occurs on polymethylmethacrylate (PMMA) beads. The setup is designed to simulate at a microscopic level the reactions that occur on items in a dishwasher, where permanent filming of calcium carbonate on drinking glasses is a problem. Our system allows us to monitor crystal growth on trapped particles in which the Raman spectrum and changes in movement of the bead are recorded. Due to the expected low level of crystallisation on the bead surfaces this allows us to obtain results quickly and with high sensitivity. The long term goal is to study the development of filming on samples in-situ with the microfl.uidic system acting as a model dishwasher.
Investigation of Skin Cancers Using MicroRaman Spectroscopy
NASA Astrophysics Data System (ADS)
Short, M. A.; Chen, X. K.; Zeng, H.; Ajlan, A. A.; McLean, D. I.; Hui, H.
2004-03-01
We have measured the Raman spectra of skin cancers, including melanoma and basal cell carcinoma, using a confocal microRaman spectrograph. In an attempt to identify the origin of the observed Raman modes, we investigated the spectra obtained from different locations of the samples, compared the observed spectra with those measured from normal human skin and pig skin, and studied the polarization dependence of the spectra. In addition, we will discuss the effects of fluorescence in the measurement of Raman spectra of skin samples.
In vitro evaluation of enamel demineralization after several overlapping CO2 laser applications.
Vieira, K A; Steiner-Oliveira, C; Soares, L E S; Rodrigues, L K A; Nobre-dos-Santos, M
2015-02-01
This study aimed to evaluate the effects of repeated CO2 laser applications on the inhibition of enamel demineralization. Sixty-five human dental enamel slabs were randomly assigned to the following groups (n = 13): control (C), one application of the CO2 laser (L1), two applications of the CO2 laser (L2), three applications of the CO2 laser (L3), and four applications of the CO2 laser (L4). Enamel slabs were irradiated by a 10.6-μm CO2 laser operating at 5 J/cm(2). The slabs were subjected to a pH-cycling regimen and then analyzed by FT-Raman spectroscopy, energy-dispersive X-ray fluorescence spectrometry (EDXRF), cross-sectional micro-hardness, and scanning electron microscopy (SEM). Statistical analysis was performed using ANOVA and Tukey tests (p < 0.05). FT-Raman spectroscopy showed a reduced carbonate content for L1, L3, and L4 groups when compared to C (p < 0.05). The EDXRF data showed no statistical differences between the control and irradiated groups for calcium and phosphorus components (p > 0.05). Cross-sectional micro-hardness data showed a statistically significant difference between the control and all irradiated groups (p < 0.05), but no difference was found among the irradiated groups (p > 0.05) up to 30-μm depth. A tendency of lower demineralization occurred in deeper depths for L3 and L4 groups. The SEM results showed that with repeated applications of the CO2 laser, a progressive melting and recrystallization of the enamel surface occurred. Repeated irradiations of dental enamel may enhance the inhibition of enamel demineralization.
Raman spectroscopic analysis of real samples: Brazilian bauxite mineralogy
NASA Astrophysics Data System (ADS)
Faulstich, Fabiano Richard Leite; Castro, Harlem V.; de Oliveira, Luiz Fernando Cappa; Neumann, Reiner
2011-10-01
In this investigation, Raman spectroscopy with 1064 and 632.8 nm excitation was used to investigate real mineral samples of bauxite ore from mines of Northern Brazil, together with Raman mapping and X-rays diffraction. The obtained results show clearly that the use of microRaman spectroscopy is a powerful tool for the identification of all the minerals usually found in bauxites: gibbsite, kaolinite, goethite, hematite, anatase and quartz. Bulk samples can also be analysed, and FT-Raman is more adequate due to better signal-to-noise ratio and representativity, although not efficient for kaolinite. The identification of fingerprinting vibrations for all the minerals allows the acquisition of Raman-based chemical maps, potentially powerful tools for process mineralogy applied to bauxite ores.
Micro-Raman analysis of glisterings in intraocular lenses
NASA Astrophysics Data System (ADS)
Rusciano, G.; Martinez, A.; Pesce, G.; Zito, G.; Sasso, A.
2017-06-01
The phenomenon of inclusions or microvacuoles in intraocular lenses (IOL), often referred to glistenings due to their appearance when visualized in slit-lamp exams, is main cause of decreased visual in people after IOL implantation. For this reason, there is a huge request by the market of new polymers able to reduce, or even eliminate, the formation of such microvacuoles. In such frame, the use of advanced optical techniques, able to provide a deeper insight on the glistering formation, is strongly required. In particular, Raman spectroscopy (RS) is ideally suited for the analysis of polymers, due to its well-know sensitivity to highly polarizable chemical groups, commonly found in the polymer chains backbones. Moreover, the combination of RS with optical microscopy (Raman micro-spectroscopy) paves the way for real, information-rich chemical mapping of polymeric materials (Raman imaging). In this paper, we analyze the formation of microvacuoles in IOLs following a thermal treatment. In particular, we performed a chemical mapping of a single microvacuole, which allowed us to infer on its effective chemical composition. In order to investigate on the reversibility of glistenings formation, this analysis was repeated as function of time after thermal treatment, in different IOL environments. It turns out that this phenomenon is partially reversible, with an almost complete disappearance of microvacuoles in a dry environment.
Application of spectroscopic techniques for the analysis of kidney stones: a pilot study
NASA Astrophysics Data System (ADS)
Shameem, K. M., Muhammed; Chawla, Arun; Bankapur, Aseefhali; Unnikrishnan, V. K.; Santhosh, C.
2016-03-01
Identification and characterization of kidney stone remains one of the important analytical tasks in the medical field. Kidney stone is a common health complication throughout the world, which may cause severe pain, obstruction and infection of urinary tract, and can lead to complete renal damage. It commonly occurs in both sexes regardless of age. Kidney stones have different composition, although each stones have a major single characteristic component. A complete understanding of a sample properties and their function can only be feasible by utilizing elemental and molecular information simultaneously. Two laser based analytical techniques; Laser Induced Breakdown spectroscopy (LIBS) and Raman spectroscopy have been used to study different types of kidney stones from different patients. LIBS and Raman spectroscopy are highly complementary spectroscopic techniques, which provide elemental and molecular information of a sample. Q-switched Nd:YAG laser at 355 nm laser having energy 17mJ per pulse at 10 Hz repetition rate was used for getting LIBS spectra. Raman measurements were carried out using a home assembled micro-Raman spectrometer. Using the recorded Raman spectra of kidney stones, we were able to differentiate different kinds of kidney stones. LIBS spectra of the same stones are showing the evidence of C, Ca, H, and O and also suggest the presence of certain pigments.
NASA Astrophysics Data System (ADS)
Liu, Zhaojun; Han, Yunxia; Han, Ligang; Cheng, Yongjian; Ma, Yiqiang; Fang, Li
2013-05-01
The pigments on the painted pottery figurines from two tombs of Northern Wei Dynasty (AD 386-534) in Luoyang were analyzed by Raman microscopy. All the pigments were identified compared with the Raman spectra of standard pigments. The red pigments were identified as haematite, the blue pigment as lapis lazuli, the green pigment as malachite, the black pigment as carbon black and the white pigment as calcite. Similar pigments were used in the two tombs despite the pottery figurines were very different in artistic style. The use of lapis lazuli as blue pigment on Chinese painted pottery figurines was found for the first time. This pigment and the painted pottery figurine of Sogdians are of great archaeological significance because it demonstrated that the trade and cultural exchanges via the Silk Road had extended to Luoyang city in the Northern Wei Dynasty. The result also confirms that micro-Raman spectroscopy is a powerful analytical method for the identification of pigments on ancient artworks.
Raman and AFM study of gamma irradiated plastic bottle sheets
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ali, Yasir; Kumar, Vijay; Dhaliwal, A. S.
2013-02-05
In this investigation, the effects of gamma irradiation on the structural properties of plastic bottle sheet are studied. The Plastic sheets were exposed with 1.25MeV {sup 60}Co gamma rays source at various dose levels within the range from 0-670 kGy. The induced modifications were followed by micro-Raman and atomic force microscopy (AFM). The Raman spectrum shows the decrease in Raman intensity and formation of unsaturated bonds with an increase in the gamma dose. AFM image displays rough surface morphology after irradiation. The detailed Raman analysis of plastic bottle sheets is presented here, and the results are correlated with the AFMmore » observations.« less
MicroRaman measurements for nuclear fuel reprocessing applications
Casella, Amanda; Lines, Amanda; Nelson, Gilbert; ...
2016-12-01
Treatment and reuse of used nuclear fuel is a key component in closing the nuclear fuel cycle. Solvent extraction reprocessing methods that have been developed contain various steps tailored to the separation of specific radionuclides, which are highly dependent upon solution properties. The instrumentation used to monitor these processes must be robust, require little or no maintenance, and be able to withstand harsh environments such as high radiation fields and aggressive chemical matrices. Our group has been investigating the use of optical spectroscopy for the on-line monitoring of actinides, lanthanides, and acid strength within fuel reprocessing streams. This paper willmore » focus on the development and application of a new MicroRaman probe for on-line real-time monitoring of the U(VI)/nitrate ion/nitric acid in solutions relevant to used nuclear fuel reprocessing. Previous research has successfully demonstrated the applicability on the macroscopic scale, using sample probes requiring larger solution volumes. In an effort to minimize waste and reduce dose to personnel, we have modified this technique to allow measurement at the microfluidic scale using a Raman microprobe. Under the current sampling environment, Raman samples typically require upwards of 10 mL and larger. Using the new sampling system, we can sample volumes at 10 μL or less, which is a scale reduction of over 1,000 fold in sample size. Finally, this paper will summarize our current work in this area including: comparisons between the macroscopic and microscopic probes for detection limits, optimized channel focusing, and application in a flow cell with varying levels of HNO 3, and UO 2(NO 3) 2.« less
Stürzl, Ninette; Lebedkin, Sergei; Klumpp, Stefanie; Hennrich, Frank; Kappes, Manfred M
2013-05-07
We describe a micro-Raman setup allowing for efficient resonance Raman spectroscopy (RRS), i.e., mapping of Raman spectra as a function of tunable laser excitation wavelength. The instrument employs angle-tunable bandpass optical filters which are integrated into software-controlled Raman and laser cleanup filter devices. These automatically follow the excitation laser wavelength and combine tunability with high bandpass transmission as well as high off-band blocking of light. Whereas the spectral intervals which can be simultaneously acquired are bandpass limited to ~350 cm(-1), they can be tuned across the spectrum of interest to access all characteristic Raman features. As an illustration of performance, we present Raman mapping of single-walled carbon nanotubes (SWNTs): (i) in a small volume of water-surfactant dispersion as well as (ii) after deposition onto a substrate. A significant improvement in the acquisition time (and efficiency) is demonstrated compared to previous RRS implementations. These results may help to establish (micro) Raman spectral mapping as a routine tool for characterization of SWNTs as well as other materials with a pronounced resonance Raman response in the visible-near-infrared spectral region.
Liu, Jikun; White, Ian; DeVoe, Don L.
2011-01-01
The use of porous polymer monoliths functionalized with silver nanoparticles is introduced in this work for high-sensitivity surface-enhanced Raman scattering (SERS) detection. Preparation of the SERS detection elements is a simple process comprising the synthesis of a discrete polymer monolith section within a silica capillary, followed by physically trapping silver nanoparticle aggregates within the monolith matrix. A SERS detection limit of 220 fmol for Rhodamine 6G (R6G) is demonstrated, with excellent signal stability over a 24 h period. The capability of the SERS-active monolith for label-free detection of biomolecules was demonstrated by measurements of bradykinin and cyctochrome c. The SERS-active monoliths can be readily integrated into miniaturized micro-total-analysis systems for on-line and label-free detection for a variety of biosensing, bioanalytical, and biomedical applications. PMID:21322579
NASA Astrophysics Data System (ADS)
Schiavi, Federica; Bolfan-Casanova, Nathalie
2017-04-01
The amount and distribution of volatiles (water, carbon dioxide …) in magmas represent key parameters for the understanding of magma processes and dynamics within volcanic plumbing systems. Micro-Raman spectroscopy is an excellent technique for accurate determination of volatile contents in magmas, as it combines several advantages. The technique is non-destructive and requires minimal sample preparation before the analysis. Its high lateral and in-depth spatial resolution is crucial for the study of small objects and samples that are chemically and texturally heterogeneous at the small scale (microns). Moreover, the high confocality allows analysis of sample regions not exposed to the surface and 3D mapping. We present a universal calibration of Raman spectroscopy for quantification of volatiles in silicate glasses. The proposed method is based on internal calibration, i.e., on the correlation between the glass water content and the ratio between the areas of the water and silicate Raman bands. Synthetic glasses with variable major element compositions (basaltic, andesitic, rhyolitic, dacitic ..) bearing different H2O (up to 7 wt%) and CO2 contents are used as standard glasses. Natural silicate glasses, mainly in the form of melt inclusions, are used to test the goodness of the proposed method. In addition to quantification of volatiles in glass, in bubble-bearing melt inclusions we perform micro-Raman spectroscopy investigation of gas-bearing bubbles for accurate determination of total volatile contents in melt inclusions.
Atomic force microscope with combined FTIR-Raman spectroscopy having a micro thermal analyzer
Fink, Samuel D [Aiken, SC; Fondeur, Fernando F [North Augusta, SC
2011-10-18
An atomic force microscope is provided that includes a micro thermal analyzer with a tip. The micro thermal analyzer is configured for obtaining topographical data from a sample. A raman spectrometer is included and is configured for use in obtaining chemical data from the sample.
In-pile Thermal Conductivity Characterization with Time Resolved Raman
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Xinwei; Hurley, David H.
The project is designed to achieve three objectives: (1) Develop a novel time resolved Raman technology for direct measurement of fuel and cladding thermal conductivity. (2) Validate and improve the technology development by measuring ceramic materials germane to the nuclear industry. (3) Conduct instrumentation development to integrate optical fiber into our sensing system for eventual in-pile measurement. We have developed three new techniques: time-domain differential Raman (TD-Raman), frequency-resolved Raman (FR-Raman), and energy transport state-resolved Raman (ET-Raman). The TD-Raman varies the laser heating time and does simultaneous Raman thermal probing, the FR-Raman probes the material’s thermal response under periodical laser heatingmore » of different frequencies, and the ET-Raman probes the thermal response under steady and pulsed laser heating. The measurement capacity of these techniques have been fully assessed and verified by measuring micro/nanoscale materials. All these techniques do not need the data of laser absorption and absolute material temperature rise, yet still be able to measure the thermal conductivity and thermal diffusivity with unprecedented accuracy. It is expected they will have broad applications for in-pile thermal characterization of nuclear materials based on pure optical heating and sensing.« less
Daood, Umer; Swee Heng, Chan; Neo Chiew Lian, Jennifer; Fawzy, Amr S
2015-06-26
To modify two-step experimental etch-and-rinse dentin adhesive with different concentrations of riboflavin and to study its effect on the bond strength, degree of conversion, along with resin infiltration within the demineralized dentin substrate, an experimental adhesive-system was modified with different concentrations of riboflavin (m/m, 0, 1%, 3%, 5% and 10%). Dentin surfaces were etched with 37% phosphoric acid, bonded with respective adhesives, restored with restorative composite-resin, and sectioned into resin-dentin slabs and beams to be stored for 24 h or 9 months in artificial saliva. Micro-tensile bond testing was performed with scanning electron microscopy to analyse the failure of debonded beams. The degree of conversion was evaluated with Fourier transform infrared spectroscopy (FTIR) at different time points along with micro-Raman spectroscopy analysis. Data was analyzed with one-way and two-way analysis of variance followed by Tukey's for pair-wise comparison. Modification with 1% and 3% riboflavin increased the micro-tensile bond strength compared to the control at 24 h and 9-month storage with no significant differences in degree of conversion (P<0.05). The most predominant failure mode was the mixed fracture among all specimens except 10% riboflavin-modified adhesive specimens where cohesive failure was predominant. Raman analysis revealed that 1% and 3% riboflavin adhesives specimens showed relatively higher resin infiltration. The incorporation of riboflavin in the experimental two-step etch-and-rinse adhesive at 3% (m/m) improved the immediate bond strengths and bond durability after 9-month storage in artificial saliva without adversely affecting the degree of conversion of the adhesive monomers and resin infiltration.
Daood, Umer; Swee Heng, Chan; Neo Chiew Lian, Jennifer; Fawzy, Amr S
2015-01-01
To modify two-step experimental etch-and-rinse dentin adhesive with different concentrations of riboflavin and to study its effect on the bond strength, degree of conversion, along with resin infiltration within the demineralized dentin substrate, an experimental adhesive-system was modified with different concentrations of riboflavin (m/m, 0, 1%, 3%, 5% and 10%). Dentin surfaces were etched with 37% phosphoric acid, bonded with respective adhesives, restored with restorative composite–resin, and sectioned into resin–dentin slabs and beams to be stored for 24 h or 9 months in artificial saliva. Micro-tensile bond testing was performed with scanning electron microscopy to analyse the failure of debonded beams. The degree of conversion was evaluated with Fourier transform infrared spectroscopy (FTIR) at different time points along with micro-Raman spectroscopy analysis. Data was analyzed with one-way and two-way analysis of variance followed by Tukey's for pair-wise comparison. Modification with 1% and 3% riboflavin increased the micro-tensile bond strength compared to the control at 24 h and 9-month storage with no significant differences in degree of conversion (P<0.05). The most predominant failure mode was the mixed fracture among all specimens except 10% riboflavin-modified adhesive specimens where cohesive failure was predominant. Raman analysis revealed that 1% and 3% riboflavin adhesives specimens showed relatively higher resin infiltration. The incorporation of riboflavin in the experimental two-step etch-and-rinse adhesive at 3% (m/m) improved the immediate bond strengths and bond durability after 9-month storage in artificial saliva without adversely affecting the degree of conversion of the adhesive monomers and resin infiltration. PMID:25257880
Jaeger, Daniel; Pilger, Christian; Hachmeister, Henning; Oberländer, Elina; Wördenweber, Robin; Wichmann, Julian; Mussgnug, Jan H; Huser, Thomas; Kruse, Olaf
2016-10-21
Oleaginous photosynthetic microalgae hold great promise as non-food feedstocks for the sustainable production of bio-commodities. The algal lipid quality can be analysed by Raman micro-spectroscopy, and the lipid content can be imaged in vivo in a label-free and non-destructive manner by coherent anti-Stokes Raman scattering (CARS) microscopy. In this study, both techniques were applied to the oleaginous microalga Monoraphidium neglectum, a biotechnologically promising microalga resistant to commonly applied lipid staining techniques. The lipid-specific CARS signal was successfully separated from the interfering two-photon excited fluorescence of chlorophyll and for the first time, lipid droplet formation during nitrogen starvation could directly be analysed. We found that the neutral lipid content deduced from CARS image analysis strongly correlated with the neutral lipid content measured gravimetrically and furthermore, that the relative degree of unsaturation of fatty acids stored in lipid droplets remained similar. Interestingly, the lipid profile during cellular adaption to nitrogen starvation showed a two-phase characteristic with initially fatty acid recycling and subsequent de novo lipid synthesis. This works demonstrates the potential of quantitative CARS microscopy as a label-free lipid analysis technique for any microalgal species, which is highly relevant for future biotechnological applications and to elucidate the process of microalgal lipid accumulation.
[Secondary Raman spectrum of beta-carotene molecule in living leaf of French phoenix tree].
Zhao, Jin-tao; Zhang, Peng-xiang; Xu, Cun-ying
2002-10-01
Under visible incidence light 514.5 nm, the Raman scattering spectrum from the beta-carotene molecule in the leaf was directly obtained after it was immediately collected from French phoenix tree without any preparing the sample but cleaning. It is very easy to collect the secondary Raman lines addition to the first Raman spectrum in situ by micro Raman. By careful comparing and analyzing the Raman lines between 2,000-3,100 cm-1 and below 2,000 cm-1 regions, we obtained the correlated relation of the first and secondary Raman lines. The study results indicated that there is no damage to the structure and configuration of beta-carotene molecule in the live leaf by controlling laser power on the sample surface and integrating time for Raman signal, but large power laser or long time irradiation on the live sample would cause very strong fluorescence background in Raman spectrum which indicated that there is a photo damage in the center of photo reaction. The Micro Raman would become one of possible in situ methods for investigating live plant molecules growing up in different environment. At last we proposed and discussed the advantages and limits in micro Raman when it is applied to investigating live molecules in botany field.
A novel micro-Raman technique to detect and characterize 4H-SiC stacking faults
DOE Office of Scientific and Technical Information (OSTI.GOV)
Piluso, N., E-mail: nicolo.piluso@imm.cnr.it; Camarda, M.; La Via, F.
A novel Micro-Raman technique was designed and used to detect extended defects in 4H-SiC homoepitaxy. The technique uses above band-gap high-power laser densities to induce a local increase of free carriers in undoped epitaxies (n < 10{sup 16} at/cm{sup −3}), creating an electronic plasma that couples with the longitudinal optical (LO) Raman mode. The Raman shift of the LO phonon-plasmon-coupled mode (LOPC) increases as the free carrier density increases. Crystallographic defects lead to scattering or recombination of the free carriers which results in a loss of coupling with the LOPC, and in a reduction of the Raman shift. Given that the LOmore » phonon-plasmon coupling is obtained thanks to the free carriers generated by the high injection level induced by the laser, we named this technique induced-LOPC (i-LOPC). This technique allows the simultaneous determination of both the carrier lifetime and carrier mobility. Taking advantage of the modifications on the carrier lifetime induced by extended defects, we were able to determine the spatial morphology of stacking faults; the obtained morphologies were found to be in excellent agreement with those provided by standard photoluminescence techniques. The results show that the detection of defects via i-LOPC spectroscopy is totally independent from the stacking fault photoluminescence signals that cover a large energy range up to 0.7 eV, thus allowing for a single-scan simultaneous determination of any kind of stacking fault. Combining the i-LOPC method with the analysis of the transverse optical mode, the micro-Raman characterization can determine the most important properties of unintentionally doped film, including the stress status of the wafer, lattice impurities (point defects, polytype inclusions) and a detailed analysis of crystallographic defects, with a high spectral and spatial resolution.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heo, T; Ye, S
2015-06-15
Purpose: To study a feasibility of micro-dosimetry with high dose-sensitivity and resolution using two-dimensional Raman mapping on the basis of carbon bonds concentration of radiochromic films Methods: Unlaminated EBT3 films with the purpose of maximal Raman data acquisition were irradiated by 6 MV beam from 5 MU to 1000 MU at the reference condition. Each film was irradiated with shielding material of lead blocking on the half of film as well as the jaw open in half for distinct dose contrast. Raman peaks of 2070 cm-1, 2095 cm-1, and 2115 cm-1 were major subjects to study, which are assumed tomore » be the spectroscopy of carbon triple bonds of monomers, carbon double bonds of polymers, and carbon triple bonds of polymers, respectively. Laser exposure for Raman spectroscopy generated peak’s trend due to polymerization by laser output and this trend was utilized to find out basic peaks related to polymerization process. The relative dose contrast in each one film was detected by Raman spectroscopy with the aid of an auto-scanning stage, comparing the dose contrast between non-irradiated area and irradiated area. Raman spatial resolution was enhanced up to 20 micrometers, assuming the spatial uniformity of radio¬active rod-shaped LiPCDA crystals. An optical scanner with 9600 dpi was used to scan the red-channel intensity to read the dose contrast for 5 MU delivered film. Results: The peak intensity for Raman wavenumber of 2070 cm-1 was used for mapping since it reflected the different peak intensities based on polymerization degree by irradiation. Dose contrast from 1000MU to 5 MU was distinguished by Raman mapping analysis, whereas optical intensity of red-channel didn’t show any difference. Conclusion: In consideration of laser effect, the quantitative analysis based on raw data of Raman mapping could provide more statistically reliable dosimetry than point measurements.« less
NASA Astrophysics Data System (ADS)
Zhou, Yan; Liu, Cheng-hui; Pu, Yang; Cheng, Gangge; Zhou, Lixin; Chen, Jun; Zhu, Ke; Alfano, Robert R.
2016-03-01
Raman spectroscopy has become widely used for diagnostic purpose of breast, lung and brain cancers. This report introduced a new approach based on spatial frequency spectra analysis of the underlying tissue structure at different stages of brain tumor. Combined spatial frequency spectroscopy (SFS), Resonance Raman (RR) spectroscopic method is used to discriminate human brain metastasis of lung cancer from normal tissues for the first time. A total number of thirty-one label-free micrographic images of normal and metastatic brain cancer tissues obtained from a confocal micro- Raman spectroscopic system synchronously with examined RR spectra of the corresponding samples were collected from the identical site of tissue. The difference of the randomness of tissue structures between the micrograph images of metastatic brain tumor tissues and normal tissues can be recognized by analyzing spatial frequency. By fitting the distribution of the spatial frequency spectra of human brain tissues as a Gaussian function, the standard deviation, σ, can be obtained, which was used to generate a criterion to differentiate human brain cancerous tissues from the normal ones using Support Vector Machine (SVM) classifier. This SFS-SVM analysis on micrograph images presents good results with sensitivity (85%), specificity (75%) in comparison with gold standard reports of pathology and immunology. The dual-modal advantages of SFS combined with RR spectroscopy method may open a new way in the neuropathology applications.
Tomkins, Matthew Robert; Liao, David Shiqi; Docoslis, Aristides
2015-01-08
A detection method that combines electric field-assisted virus capture on antibody-decorated surfaces with the "fingerprinting" capabilities of micro-Raman spectroscopy is demonstrated for the case of M13 virus in water. The proof-of-principle surface mapping of model bioparticles (protein coated polystyrene spheres) captured by an AC electric field between planar microelectrodes is presented with a methodology for analyzing the resulting spectra by comparing relative peak intensities. The same principle is applied to dielectrophoretically captured M13 phage particles whose presence is indirectly confirmed with micro-Raman spectroscopy using NeutrAvidin-Cy3 as a labeling molecule. It is concluded that the combination of electrokinetically driven virus sampling and micro-Raman based signal transduction provides a promising approach for time-efficient and in situ detection of viruses.
Tomkins, Matthew Robert; Liao, David Shiqi; Docoslis, Aristides
2015-01-01
A detection method that combines electric field-assisted virus capture on antibody-decorated surfaces with the “fingerprinting” capabilities of micro-Raman spectroscopy is demonstrated for the case of M13 virus in water. The proof-of-principle surface mapping of model bioparticles (protein coated polystyrene spheres) captured by an AC electric field between planar microelectrodes is presented with a methodology for analyzing the resulting spectra by comparing relative peak intensities. The same principle is applied to dielectrophoretically captured M13 phage particles whose presence is indirectly confirmed with micro-Raman spectroscopy using NeutrAvidin-Cy3 as a labeling molecule. It is concluded that the combination of electrokinetically driven virus sampling and micro-Raman based signal transduction provides a promising approach for time-efficient and in situ detection of viruses. PMID:25580902
Defeyt, C; Van Pevenage, J; Moens, L; Strivay, D; Vandenabeele, P
2013-11-01
In art analysis, copper phthalocyanine (CuPc) is often identified as an important pigment (PB15) in 20th century artworks. Raman spectroscopy is a very valuable technique for the detection of this pigment in paint systems. However, PB15 is used in different polymorphic forms and identification of the polymorph could retrieve information on the production process of the pigment at the moment. Raman spectroscopy, being a molecular spectroscopic method of analysis, is able to discriminate between polymorphs of crystals. However, in the case of PB15, spectral interpretation is not straightforward, and Raman data treatment requires some improvements concerning the PB15 polymorphic discrimination in paints. Here, Raman spectroscopy is combined with chemometrical analysis in order to develop a procedure allowing us to identify the PB15 crystalline structure in painted layers and in artworks. The results obtained by Linear Discriminant Analysis (LDA), using intensity ratios as variables, demonstrate the ability of this procedure to predict the crystalline structure of a PB15 pigment in unknown paint samples. Copyright © 2013 Elsevier B.V. All rights reserved.
Micro-Raman spectroscopy study of ALVAC virus infected chicken embryo cells
NASA Astrophysics Data System (ADS)
Misra, Anupam K.; Kamemoto, Lori E.; Hu, Ningjie; Dykes, Ava C.; Yu, Qigui; Zinin, Pavel V.; Sharma, Shiv K.
2011-05-01
Micro- Raman spectroscopic investigation of ALVAC virus and of normal chicken embryo fibroblast cells and the cells infected with ALVAC virus labeled with green fluorescence protein (GFP) were performed with a 785 nm laser. Good quality Micro-Raman spectra of the Alvac II virus were obtained. These spectra show that the ALVAC II virus contains buried tyrosine residues and the coat protein of the virus has α-helical structure. A comparison of Raman spectra of normal and virus infected chicken embryo fibroblast cells revealed that the virus infected cells show additional bands at 535, 928, and 1091 cm-1, respectively, corresponding to δ(C-O-C) glycosidic ring, protein α-helix, and DNA (O-P-O) modes. In addition, the tyrosine resonance double (833 and 855 cm-1) shows reversal in the intensity of the higher-frequency band as compared to the normal cells that can be used to identify the infected cells. In the C-H stretching region, the infected cells show bands with higher intensity as compared to that of the corresponding bands in the normal cells. We also found that the presence of GFP does not affect the Raman spectra of samples when using a 785 nm micro-Raman system because the green fluorescence wavelength of GFP is well below the Stokes-Raman shifted spectral region.
Species-specific detection of processed animal proteins in feed by Raman spectroscopy.
Mandrile, Luisa; Amato, Giuseppina; Marchis, Daniela; Martra, Gianmario; Rossi, Andrea Mario
2017-08-15
The existing European Regulation (EC n° 51/2013) prohibits the use of animals meals in feedstuffs in order to prevent Bovine Spongiform Encephalopathy infection and diffusion, however the legislation is rapidly moving towards a partial lifting of the "feed ban" and the competent control organisms are urged to develop suitable analytical methods able to avoid food safety incidents related to animal origin products. The limitations of the official methods (i.e. light microscopy and Polymerase Chain Reaction) suggest exploring new analytic ways to get reliable results in a short time. The combination of spectroscopic techniques with optical microscopy allows the development of an individual particle method able to meet both selectivity and sensitivity requirements (0.1%w/w). A spectroscopic method based on Fourier Transform micro-Raman spectroscopy coupled with Discriminant Analysis is here presented. This approach could be very useful for in-situ applications, such as customs inspections, since it drastically reduces time and costs of analysis. Copyright © 2017. Published by Elsevier Ltd.
Gierlinger, Notburga
2016-01-01
Abstract Scanning probe microscopies and spectroscopies, especially AFM and Confocal Raman microscopy are powerful tools to characterize biological materials. They are both non‐destructive methods and reveal mechanical and chemical properties on the micro and nano‐scale. In the last years the interest for increasing the lateral resolution of optical and spectral images has driven the development of new technologies that overcome the diffraction limit of light. The combination of AFM and Raman reaches resolutions of about 50–150 nm in near‐field Raman and 1.7–50 nm in tip enhanced Raman spectroscopy (TERS) and both give a molecular information of the sample and the topography of the scanned surface. In this review, the mentioned approaches are introduced, the main advantages and problems for application on biological samples discussed and some examples for successful experiments given. Finally the potential of colocated AFM and Raman measurements is shown on a case study of cellulose‐lignin films: the topography structures revealed by AFM can be related to a certain chemistry by the colocated Raman scan and additionally the mechanical properties be revealed by using the digital pulsed force mode. Microsc. Res. Tech. 80:30–40, 2017. © 2016 Wiley Periodicals, Inc. PMID:27514318
Screening and staging for non-small cell lung cancer by serum laser Raman spectroscopy.
Wang, Hong; Zhang, Shaohong; Wan, Limei; Sun, Hong; Tan, Jie; Su, Qiucheng
2018-08-05
Lung cancer is the leading cause of cancer-related death worldwide. Current clinical screening methods to detect lung cancer are expensive and associated with many complications. Raman spectroscopy is a spectroscopic technique that offers a convenient method to gain molecular information about biological samples. In this study, we measured the serum Raman spectral intensity of healthy volunteers and patients with different stages of non-small cell lung cancer. The purpose of this study was to evaluate the application of serum laser Raman spectroscopy as a low cost alternative method in the screening and staging of non-small cell lung cancer (NSCLC). The Raman spectra of the sera of peripheral venous blood were measured with a LabRAM HR 800 confocal Micro Raman spectrometer for individuals from five groups including 14 healthy volunteers (control group), 23 patients with stage I NSCLC (stage I group), 24 patients with stage II NSCLC (stage II group), 19 patients with stage III NSCLC (stage III group), 11 patients with stage IV NSCLC (stage IV group). Each serum sample was measured 3 times at different spots and the average spectra represented the signal of Raman spectra in each case. The Raman spectrum signal data of the five groups were statistically analyzed by analysis of variance (ANOVA), principal component analysis (PCA), linear discriminant analysis (LDA), and cross-validation. Raman spectral intensity was sequentially reduced in serum samples from control group, stage I group, stage II group and stage III/IV group. The strongest peak intensity was observed in the control group, and the weakest one was found in the stage III/IV group at bands of 848 cm -1 , 999 cm -1 , 1152 cm -1 , 1446 cm -1 and 1658 cm -1 (P < 0.05). Linear discriminant analysis showed that the sensitivity to identify healthy people, stage I, stage II, and stage III/IV NSCLC was 86%, 65%, 75%, and 87%, respectively; the specificity was 95%, 94%, 88%, and 93%, respectively; and the overall accuracy rate was 92% (71/77). The laser Raman spectroscopy can effectively identify patients with stage I, stage II or stage III/IV Non-Small Cell Lung cancer using patient serum samples. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Komachi, Yuichi; Sato, Hidetoshi; Tashiro, Hideo
2006-10-01
An intravascular catheter for Raman spectroscopic detection and analysis of coronary atherosclerotic disease has been developed. The catheter, having an outer diameter of 2 mm, consisted of a side-view-type micro-Raman probe, an imaging fiber bundle, a working channel (injection drain), and a balloon. By inflating the balloon, the probe was brought close to the inner wall of a modeled blood flow system and detected a phantom target buried in the wall. Results obtained demonstrate the possibility of using the spectroscopic catheter for molecular diagnosis of coronary lesions.
NASA Astrophysics Data System (ADS)
Chan, James W.; Liu, Rui; Matthews, Dennis L.
2012-06-01
Laser tweezers Raman spectroscopy (LTRS) combines optical trapping with micro-Raman spectroscopy to enable label-free biochemical analysis of individual cells and small biological particles in suspension. The integration of the two technologies greatly simplifies the sample preparation and handling of suspension cells for spectroscopic analysis in physiologically meaningful conditions. In our group, LTRS has been used to study the effects of external perturbations, both chemical and mechanical, on the biochemistry of the cell. Single cell dynamics can be studied by performing longitudinal studies to continuously monitor the response of the cell as it interacts with its environment. The ability to carry out these measurements in-vitro makes LTRS an attractive tool for many biomedical applications. Here, we discuss the use of LTRS to study the response of cancer cells to chemotherapeutics and bacteria cells to antibiotics and show that the life cycle and apoptosis of the cells can be detected. These results show the promise of LTRS for drug discovery/screening, antibiotic susceptibility testing, and chemotherapy response monitoring applications. In separate experiments, we study the response of red blood cells to the mechanical forces imposed on the cell by the optical tweezers. A laser power dependent deoxygenation of the red blood cell in the single beam trap is reported. Normal, sickle cell, and fetal red blood cells have a different behavior that enables the discrimination of the cell types based on this mechanochemical response. These results show the potential utility of LTRS for diagnosing and studying red blood cell diseases.
Micro-optical fiber probe for use in an intravascular Raman endoscope.
Komachi, Yuichi; Sato, Hidetoshi; Aizawa, Katsuo; Tashiro, Hideo
2005-08-01
We believe that we have developed the narrowest optical-fiber Raman probe ever reported, 600 microm in total diameter, that can be inserted into coronary arteries. The selection of suitable optical fibers, filters, and a processing method is discussed. Custom-made filters attached to the front end of a probe eliminate the background Raman signals of the optical fiber itself. The experimental evaluation of various optical fibers is carried out for the selection of suitable fibers. Measurement of the Raman spectra of an atherosclerotic lesion of a rabbit artery in vitro demonstrates the excellent performance of the micro-Raman probe.
Frosch, Torsten; Tarcea, Nicolae; Schmitt, Michael; Thiele, Hans; Langenhorst, Falko; Popp, Jürgen
2007-02-01
The great capabilities of UV Raman imaging have been demonstrated on the three Martian meteorites: Sayh al Uhaymir, Dar al Gani, and Zagami. Raman spectra without disturbing fluorescence and with high signal-to-noise-ratios and full of spectral features were derived. This result is of utmost importance for the development of powerful instruments for space missions. By point scanning the surfaces of the meteorite samples, it was possible for the first time to construct UV-Raman images out of the array of Raman spectra. Deep-UV Raman images are to the best of our knowledge presented for the first time. The images were used for a discussion of the chemical-mineralogical composition and texture of the meteorite surfaces. Comparative Raman studies applying visible and NIR Raman excitation wavelengths demonstrate a much better performance for UV Raman excitation. This comparative study of different Raman excitation wavelengths at the same sample spots was done by constructing a versatile, robust sample holder with a fixed micro-raster. The overall advantages of UV resonance Raman spectroscopy in terms of sensitivity and selectivity are demonstrated and discussed. Finally the application of this new technique for a UV Raman instrument for envisaged astrobiological focused space missions is suggested.
NASA Astrophysics Data System (ADS)
Reymond, Helena; Rudolf von Rohr, Philipp
2017-11-01
The operando study of CO2 hydrogenation is fundamental for a more rational optimisation of heterogeneous catalyst and reactor designs. To further complement the established efficiency of microreactors in reaction screening and bridge the operating and optical gaps, a micro-view-cell is presented for Raman microscopy at extreme conditions with minimum flow interference for genuine reaction analysis. Based on a flat sapphire window unit sealed in a plug flow-type enclosure holding the sample, the cell features unique 14 mm working distance and 0.36 numerical aperture and resists 400 °C and 500 bars. The use of the cell as an in situ tool for fast process monitoring and surface catalyst characterisation is demonstrated with phase behaviour and chemical analysis of the methanol synthesis over a commercial Cu/ZnO/Al2O3 catalyst.
Chen, Di-Ling; Li, Ning; Lin, Li; Long, He-ming; Lin, Hui; Chen, Jun; Zhang, He-Ming; Zeng, Chang-chun; Liu, Song-Hao
2014-04-11
Male infertility is a stressful and frustrating problem for the society, but a number of male infertility treatments are available as traditional Chinese medicine strategies which have been tried with variable success, while evidence is still limited on whether-or how much-herbs or supplements might help increase fertility, so the aim of this study was to investigate if the oligosaccharides extracted from Morinda officialis, a Chinese herb, is the active constituents to the fertility. In this study, we prepared the H2O2-demaged human sperm, cocultured with the oligosaccharides in vitro, then observed the changes of the DNA using confocal micro-Raman spectroscopy, and comparative analysis the differences of the spectra of different treated groups. The results showed that the oligosaccharides extracted from Morinda officialis can keep the "Raman fingerprints" of the human sperm DNA almost the same as those of the control groups, but very different from the H2O2-induced groups, especially the intensity of bands at 787, 993, 1094, 1254, 1340, 1376, 1421, 1443, 1487, 1577 and 1662cm(-1) which could be as potential targets for the drugs finding, and further principal component analysis was successfully used to classify the Raman spectra of normal control and model groups. This results suggested that the oligosaccharides can protect the DNA of human sperm from being damaged by H2O2, and which was one of the active constituents of Morinda officialis on treating infertility. It was also demonstrated that Morinda officialis as a tonifying and replenishing natural herb medicine can be used to enhance reproductive functions, and the Raman spectroscopy could be an applicable technology for screening active components in vitro from herbs. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Subramanian, B; Thibault, M-H; Djaoued, Y; Pelletier, C; Touaibia, M; Tchoukanova, N
2015-11-07
Astaxanthin (ASTX) is a keto carotenoid, which possesses a non-polar linear central conjugated chain and polar β-ionone rings with ketone and hydroxyl groups at the extreme ends. It is well known as a super anti-oxidant, and recent clinical studies have established its nutritional benefits. Although it occurs in several forms, including free molecule, crystalline, aggregates and various geometrical isomers, in nature it exists primarily in the form of esters. Marine animals accumulate ASTX from primary sources such as algae. Nordic shrimps (P. borealis), which are harvested widely in the Atlantic Ocean, form a major source of astaxanthin esters. "Astaxanthin-rich shrimp oil" was developed as a novel product in a shrimp processing plant in Eastern Canada. A compositional analysis of the shrimp oil was performed, with a view to possibly use it as a nutraceutical product for humans and animals. Astaxanthin-rich shrimp oil contains 50% MUFAs and 22% PUFAs, of which 20% are omega-3. In addition, the shrimp oil contains interesting amounts of EPA and DHA, with 10%/w and 8%/w, respectively. Astaxanthin concentrations varied between 400 and 1000 ppm, depending on the harvesting season of the shrimp. Astaxanthin and its esters were isolated from the oil and analysed by NMR, FTIR and Micro-Raman spectroscopy. Astaxanthin mono- and diesters were synthesized and used as standards for the analysis of astaxanthin-rich shrimp oil. NMR and vibrational spectroscopy techniques were successfully used for the rapid characterization of monoesters and diesters of astaxanthin. Raman spectroscopy provided important intermolecular interactions present in the esterified forms of astaxanthin molecules. Also discussed in this paper is the use of NMR, FTIR and Micro-Raman spectroscopy for the detection of astaxanthin esters in shrimp oil.
Synthesis of ZnO decorated graphene nanocomposite for enhanced photocatalytic properties
NASA Astrophysics Data System (ADS)
Gayathri, S.; Jayabal, P.; Kottaisamy, M.; Ramakrishnan, V.
2014-05-01
Zinc oxide/Graphene (GZ) composites with different concentrations of ZnO were successfully synthesized through simple chemical precipitation method. The X-ray diffraction pattern and the micro-Raman spectroscopic technique revealed the formation of GZ composite, and the energy dispersive X-ray spectrometry analysis showed the purity of the prepared samples. The ZnO nanoparticles decorated graphene sheets were clearly visible in the field emission scanning electron micrograph. Raman mapping was employed to analyze the homogeneity of the prepared samples. The diffuse-reflectance spectra clearly indicated that the formation of GZ composites promoted the absorption in the visible region also. The photocatalytic activity of ZnO and GZ composites was studied by the photodegradation of Methylene blue dye. The results revealed that the GZ composites exhibited a higher photocatalytic activity than pristine ZnO. Hence, we proposed a simple wet chemical method to synthesize GZ composite and its application on photocatalysis was demonstrated.
Low vibration high numerical aperture automated variable temperature Raman microscope
Tian, Y.; Reijnders, A. A.; Osterhoudt, G. B.; ...
2016-04-05
Raman micro-spectroscopy is well suited for studying a variety of properties and has been applied to wide- ranging areas. Combined with tuneable temperature, Raman spectra can offer even more insights into the properties of materials. However, previous designs of variable temperature Raman microscopes have made it extremely challenging to measure samples with low signal levels due to thermal and positional instability as well as low collection efficiencies. Thus, contemporary Raman microscope has found limited applicability to probing the subtle physics involved in phase transitions and hysteresis. This paper describes a new design of a closed-cycle, Raman microscope with full polarizationmore » rotation. High collection efficiency, thermal and mechanical stability are ensured by both deliberate optical, cryogenic, and mechanical design. Measurements on two samples, Bi 2Se 3 and V 2O 3, which are known as challenging due to low thermal conductivities, low signal levels and/or hysteretic effects, are measured with previously undemonstrated temperature resolution.« less
Low vibration high numerical aperture automated variable temperature Raman microscope
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tian, Y.; Reijnders, A. A.; Osterhoudt, G. B.
Raman micro-spectroscopy is well suited for studying a variety of properties and has been applied to wide- ranging areas. Combined with tuneable temperature, Raman spectra can offer even more insights into the properties of materials. However, previous designs of variable temperature Raman microscopes have made it extremely challenging to measure samples with low signal levels due to thermal and positional instability as well as low collection efficiencies. Thus, contemporary Raman microscope has found limited applicability to probing the subtle physics involved in phase transitions and hysteresis. This paper describes a new design of a closed-cycle, Raman microscope with full polarizationmore » rotation. High collection efficiency, thermal and mechanical stability are ensured by both deliberate optical, cryogenic, and mechanical design. Measurements on two samples, Bi 2Se 3 and V 2O 3, which are known as challenging due to low thermal conductivities, low signal levels and/or hysteretic effects, are measured with previously undemonstrated temperature resolution.« less
Oral pathology diagnosis by means of micro-Raman spectroscopy on biopsies and blood serum
NASA Astrophysics Data System (ADS)
Zenone, F.; Lepore, M.; Perna, G.; Carmone, P.; Delfino, I.; Gaeta, G. M.; Capozzi, V.
2007-02-01
Pemphigus vulgaris is a chronic, autoimmune, blistering disease of the skin and mucous membranes with a potentially fatal outcome. In this case micro-Raman spectroscopy (μ-RS) can provide a powerful tool for a not invasive analysis of biological tissue for biopsy and in vivo investigation. Based on the evaluation of molecular vibration frequencies, the μ-RS is able to detect the main molecular bonds of protein constituents, as the C-H and C-C ones. Changes in frequency or in the relative intensity of the vibration modes revealed by μ-RS can be related to changes of chemical bond and of protein structure induced by pathology. Quantitative information on the intensity variation of specific Raman lines can be extracted by Partial Least Square (PLS) analysis. μ-RS was performed on some samples of oral tissue and blood serum from informed patients affected by pemphigus vulgaris (an oral pathology) at different pathology stages. The spectra were measured by means of a Raman confocal microspectrometer apparatus using the 633 nm line of a He- Ne laser source. The main protein bonds are clearly detectable in the considered samples giving important information on the integrity and on the state of tissue and blood serum components (lipids and proteins), and consequently on the occurrence of pathology.
Visible micro-Raman spectroscopy for determining glucose content in beverage industry.
Delfino, I; Camerlingo, C; Portaccio, M; Ventura, B Della; Mita, L; Mita, D G; Lepore, M
2011-07-15
The potential of Raman spectroscopy with excitation in the visible as a tool for quantitative determination of single components in food industry products was investigated by focusing the attention on glucose content in commercial sport drinks. At this aim, micro-Raman spectra in the 600-1600cm(-1) wavenumber shift region of four sport drinks were recorded, showing well defined and separated vibrational fingerprints of the various contained sugars (glucose, fructose and sucrose). By profiting of the spectral separation of some peculiar peaks, glucose content was quantified by using a multivariate statistical analysis based on the interval Partial Least Square (iPLS) approach. The iPLS model needed for data analysis procedure was built by using glucose aqueous solutions at known sugar concentrations as calibration data. This model was then applied to sport drink spectra and gave predicted glucose concentrations in good agreement with the values obtained by using a biochemical assay. These results represent a significant step towards the development of a fast and simple method for the on-line glucose quantification in products of food and beverage industry. Copyright © 2011 Elsevier Ltd. All rights reserved.
Analysis of thin-film polymers using attenuated total internal reflection-Raman microspectroscopy.
Tran, Willie; Tisinger, Louis G; Lavalle, Luis E; Sommer, André J
2015-01-01
Two methods commonly employed for molecular surface analysis and thin-film analysis of microscopic areas are attenuated total reflection infrared (ATR-IR) microspectroscopy and confocal Raman microspectroscopy. In the former method, the depth of the evanescent probe beam can be controlled by the wavelength of light, the angle of incidence, or the refractive index of the internal reflection element. Because the penetration depth is proportional to the wavelength of light, one could interrogate a smaller film thickness by moving from the mid-infrared region to the visible region employing Raman spectroscopy. The investigation of ATR Raman microspectroscopy, a largely unexplored technique available to Raman microspectroscopy, was carried out. A Renishaw inVia Raman microscope was externally modified and used in conjunction with a solid immersion lens (SIL) to perform ATR Raman experiments. Thin-film polymer samples were analyzed to explore the theoretical sampling depth for experiments conducted without the SIL, with the SIL, and with the SIL using evanescent excitation. The feasibility of micro-ATR Raman was examined by collecting ATR spectra from films whose thickness measured from 200 to 60 nm. Films of these thicknesses were present on a much thicker substrate, and features from the underlying substrate did not become visible until the thin film reached a thickness of 68 nm.
In situ micro-Raman analysis and X-ray diffraction of nickel silicide thin films on silicon.
Bhaskaran, M; Sriram, S; Perova, T S; Ermakov, V; Thorogood, G J; Short, K T; Holland, A S
2009-01-01
This article reports on the in situ analysis of nickel silicide (NiSi) thin films formed by thermal processing of nickel thin films deposited on silicon substrates. The in situ techniques employed for this study include micro-Raman spectroscopy (microRS) and X-ray diffraction (XRD); in both cases the variations for temperatures up to 350 degrees C has been studied. Nickel silicide thin films formed by vacuum annealing of nickel on silicon were used as a reference for these measurements. In situ analysis was carried out on nickel thin films on silicon, while the samples were heated from room temperature to 350 degrees C. Data was gathered at regular temperature intervals and other specific points of interest (such as 250 degrees C, where the reaction between nickel and silicon to form Ni(2)Si is expected). The transformations from the metallic state, through the intermediate reaction states, until the desired metal-silicon reaction product is attained, are discussed. The evolution of nickel silicide from the nickel film can be observed from both the microRS and XRD in situ studies. Variations in the evolution of silicide from metal for different silicon substrates are discussed, and these include (100) n-type, (100) p-type, and (110) p-type silicon substrates.
NASA Astrophysics Data System (ADS)
Sanson, A.; Pokrovski, G. S.; Giarola, M.; Mariotto, G.
2015-01-01
The vibrational dynamics of germanium dioxide in the rutile structure has been investigated by using polarized micro-Raman scattering spectroscopy coupled with first-principles calculations. Raman spectra were carried out in backscattering geometry at room temperature from micro-crystalline samples either unoriented or oriented by means of a micromanipulator, which enabled successful detection and identification of all the Raman active modes expected on the basis of the group theory. In particular, the Eg mode, incorrectly assigned or not detected in the literature, has been definitively observed by us and unambiguously identified at 525 \\text{cm}-1 under excitation by certain laser lines, thus revealing an unusual resonance phenomenon. First-principles calculations within the framework of the density functional theory allow quantifying both wave number and intensity of the Raman vibrational spectra. The excellent agreement between calculated and experimental data corroborates the reliability of our findings.
Lazidou, Dimitra; Lampakis, Dimitrios; Karapanagiotis, Ioannis; Panayiotou, Costas
2018-01-01
The cross-section stratifications of samples, which were removed from six icons, are studied using optical microscopy, micro-Raman spectroscopy, and micro-Fourier transform infrared (FT-IR) spectroscopy. The icons, dated from the 14th to 19th centuries, are prominent examples of Byzantine painting art and are attributed to different artistic workshops of northern Greece. The following materials are identified in the cross-sections of the icon samples using micro-Raman spectroscopy: anhydrite; calcite; carbon black; chrome yellow; cinnabar; gypsum; lead white; minium; orpiment; Prussian blue; red ochre; yellow ochre; and a paint of organic origin which can be either indigo ( Indigofera tinctoria L. and others) or woad ( Isatis tinctoria L.). The same samples are investigated using micro-FT-IR which leads to the following identifications: calcite; calcium oxalates; chrome yellow; gypsum; kaolinite; lead carboxylates; lead sulfate (or quartz); lead white; oil; protein; Prussian blue; saponified oil; shellac; silica; and tree resin. The study of the cross-sections of the icon samples reveals the combinations of the aforementioned inorganic and organic materials. Although the icons span over a long period of six centuries, the same stratification comprising gypsum ground layer, paint layers prepared by modified "egg tempera" techniques (proteinaceous materials mixed with oil and resins), and varnish layer is revealed in the investigated samples. Moreover, the presence of three layers of varnishes, one at the top and other two as intermediate layers, in the cross-section analysis of a sample from Virgin and Child provide evidence of later interventions.
Raman sorting and identification of single living micro-organisms with optical tweezers
NASA Astrophysics Data System (ADS)
Xie, Changan; Chen, De; Li, Yong-Qing
2005-07-01
We report on a novel technique for sorting and identification of single biological cells and food-borne bacteria based on laser tweezers and Raman spectroscopy (LTRS). With this technique, biological cells of different physiological states in a sample chamber were identified by their Raman spectral signatures and then they were selectively manipulated into a clean collection chamber with optical tweezers through a microchannel. As an example, we sorted the live and dead yeast cells into the collection chamber and validated this with a standard staining technique. We also demonstrated that bacteria existing in spoiled foods could be discriminated from a variety of food particles based on their characteristic Raman spectra and then isolated with laser manipulation. This label-free LTRS sorting technique may find broad applications in microbiology and rapid examination of food-borne diseases.
Infrared micro-spectroscopy of human tissue: principles and future promises.
Diem, Max; Ergin, Ayşegül; Remiszewski, Stan; Mu, Xinying; Akalin, Ali; Raz, Dan
2016-06-23
This article summarizes the methods employed, and the progress achieved over the past two decades in applying vibrational (Raman and IR) micro-spectroscopy to problems of medical diagnostics and cellular biology. During this time, several research groups have verified the enormous information contained in vibrational spectra; in fact, information on protein, lipid and metabolic composition of cells and tissues can be deduced by decoding the observed vibrational spectra. This decoding process is aided by the availability of computer workstations and advanced algorithms for data analysis. Furthermore, commercial instrumentation for the fast collection of both Raman and infrared micro-spectral data has enabled the collection of images of cells and tissues based solely on vibrational spectroscopic data. The progress in the field has been manifested by a steady increase in the number and quality of publications submitted by established and new research groups in vibrational spectroscopy in the biological and biomedical arenas.
Optofluidic-Tunable Color Filters And Spectroscopy Based On Liquid-Crystal Microflows
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cuennet, J. G.; Vasdekis, Andreas E.; Psaltis, D.
The integration of color filters with microfluidics has attracted substantial attention in recent years, for on-chip absorption, fluorescence, or Raman analysis. We describe such tunable filters based on the micro-flow of liquid crystals. The filter operation is based on the wavelength dependent liquid crystal birefringence that can be tuned by modifying the flow velocity field in the microchannel. The latter is possible both temporally and spatially by varying the inlet pressure and the channel geometry respectively. We explored the use of these optofluidic filters for on-chip absorption spectroscopy; by integrating the distance dependent color filter with a dye-filled micro-channel, themore » absorption spectrum of a dye could be measured. Liquid crystal microflows simplify substantially the optofluidic integration, actuation and tuning of color filters for lab-on-a-chip spectroscopic applications.« less
NASA Astrophysics Data System (ADS)
Caudin, J. P.; Beljebbar, A.; Sockalingum, G. D.; Angiboust, J. F.; Manfait, M.
1995-11-01
Direct analysis of sub-femtogram quantities of chemical compounds on thin layer chromatography plates has been made possible by associating Fourier transform Raman microspectroscopy with SERS spectroscopy. The interfacing elements of the FT Raman microscope system are discussed and optimised such that a lateral resolution on the micron scale is achieved in the sample plane. Micro-FT SERS results obtained from a model biological molecule indicate preservation of molecular conformation upon adsorption at the SERS active surface. With NIR radiation it is thus possible to analyse plates with or without fluorescence indicators.
NASA Astrophysics Data System (ADS)
Ye, Dong; Wu, Shu-Qun; Yu, Yao; Liu, Lin; Lu, Xin-Pei; Wu, Yue
2014-03-01
In this work, a mask-free method is introduced for patterned nitrogen doping of graphene using a micro-plasma jet under ambient condition. Raman and X-ray photoelectron spectroscopy spectra indicate that nitrogen atoms are incorporated into the graphene lattice with the two-dimensional spatial distribution precisely controlled in the range of mm down to 10 μm. Since the chemistry of the micro-plasma jet can be controlled by the choice of the gas mixture, this direct writing process with micro-plasma jet can be a versatile approach for patterned functionalization of graphene with high spatial resolution. This could have promising applications in graphene-based electronics.
Polarized micro Raman spectroscopy of bilayer graphene
NASA Astrophysics Data System (ADS)
Moon, Hyerim; Yoon, Duhee; Son, Young-Woo; Cheong, Hyeonsik
2009-03-01
The frequency of Raman 2D band of the graphite depends on the excitation laser energy. This phenomenon is explained with double resonance Raman process. In polarized micro-Raman spectroscopy of single layer graphene, Raman G band (˜1586 cm-1) is isotropic, and 2D band (˜2686 cm-1) strongly depends on relative polarizations of the incident and scattered photons. This strong polarization dependence originates from inhomogeneous optical absorption and emission mediated by resonant electron-phonon interaction. In bi-layer graphene, Raman 2D band can be decomposed into four Lorenztian peaks which can be interpreted in terms of the four transition paths in the double resonance Raman process. We investigated the polarization dependence of each Lorenztian peak in the Raman 2D band of bi-layer graphene for different excitation laser energies. Strong polarization dependence of the Raman 2D band, similar to the case of single layer graphene, is observed. The excitation energy dependence of the polarized Raman scattering is analyzed in terms of the band structure of bi-layer graphene.
Novel Raman Techniques for Imaging and Sensing
NASA Astrophysics Data System (ADS)
Edwards, Perry S.
Raman scattering spectroscopy is extensively demonstrated as a label-free, chemically selective sensing and imaging technique for a multitude of chemical and biological applications. The ability to detect "fingerprint" spectral signatures of individual molecules, without the need to introduce chemical labelers, makes Raman scattering a powerful sensing technique. However, spectroscopy based on spontaneous Raman scattering traditionally suffers from inherently weak signals due to small Raman scattering cross-sections. Thus, considerable efforts have been put forth to find pathways towards enhancing Raman signals to bolster sensitivity for detecting small concentrations of molecules or particles. The development of coherent Raman techniques that can offer orders of magnitude increase in signal have garnered significant interest in recent years for their application in imaging; such techniques include coherent anti-Stokes Raman scattering and stimulated Raman scattering. Additionally, methods to enhance the local field of either the pump or generated Raman signal, such as through surface enhanced Raman scattering, have been investigated for their orders of magnitude improvement in sensitivity and single molecule sensing capability. The work presented in this dissertation describes novel techniques for performing high speed and highly sensitive Raman imaging as well as sensing applications towards bioimaging and biosensing. Coherent anti-Stokes Raman scattering (CARS) is combined with holography to enable recording of high-speed (single laser shot), wide field CARS holograms which can be used to reconstruct the both the amplitude and the phase of the anti-Stokes field therefore allowing 3D imaging. This dissertation explores CARS holography as a viable label-free bio-imaging technique. A Raman scattering particle sensing system is also developed that utilizes wave guide properties of optical fibers and ring-resonators to perform enhanced particle sensing. Resonator-enhanced particle sensing is experimentally examined as a new method for enhancing Raman scattering from particles interacting with circulating optical fields within both a fiber ring-cavity and whispering gallery mode microtoroid microresonators. The achievements described in this dissertation include: (1) Demonstration of the bio-imaging capability of CARS holography by recording of CARS holograms of subcellular components in live cancer (HeLa) cells. (2) Label-free Raman microparticle sensing using a tapered optical fibers. A tapered fiber can guide light to particles adsorbed on the surface of the taper to generate scattered Raman signal which can be collected by a microRaman detection system. (3) Demonstration of the proof of concept of resonator-enhanced Raman spectroscopy in a fiber ring resonator consisting of a section of fiber taper. (4) A method for locking the pump laser to the resonate frequencies of a resonator. This is demonstrated using a fiber ring resonator and microtoroid microresonators. (5) Raman scattered signal from particles adhered to microtoroid microresonators is acquired using 5 seconds of signal integration time and with the pump laser locked to a cavity resonance. (6) Theoretical analysis is performed that indicates resonator-enhanced Raman scattering from microparticles adhered to microresonators can be achieved with the pump laser locked to the frequency of a high-Q cavity resonant mode.
Oriero, Dennis A; Weakley, Andrew T; Aston, D Eric
2012-01-01
Rheological and micro-Raman time-series characterizations were used to investigate the chemical evolutionary changes of silica sol–gel mixtures for electrospinning fibers to immobilize an enzyme (tyrosinase). Results of dynamic rheological measurements agreed with the expected structural transitions associated with reacting sol–gel systems. The electrospinning sols exhibited shear-thinning behavior typical of a power law model. Ultrafine (200–300 nm diameter) fibers were produced at early and late times within the reaction window of approximately one hour from initial mixing of sol solutions with and without enzyme; diameter distributions of these fibers showed much smaller deviations than expected. The enzyme markedly increased magnitudes of both elastic and viscous moduli but had no significant impact on final fiber diameters, suggesting that the shear-thinning behavior of both sol–gel mixtures is dominant in the fiber elongation process. The time course and scale for the electrospinning batch fabrication show strong correlations between the magnitudes in rheological property changes over time and the chemical functional group evolution obtained from micro-Raman time-series analysis of the reacting sol–gel systems. PMID:27877486
Jaeger, Daniel; Pilger, Christian; Hachmeister, Henning; Oberländer, Elina; Wördenweber, Robin; Wichmann, Julian; Mussgnug, Jan H.; Huser, Thomas; Kruse, Olaf
2016-01-01
Oleaginous photosynthetic microalgae hold great promise as non-food feedstocks for the sustainable production of bio-commodities. The algal lipid quality can be analysed by Raman micro-spectroscopy, and the lipid content can be imaged in vivo in a label-free and non-destructive manner by coherent anti-Stokes Raman scattering (CARS) microscopy. In this study, both techniques were applied to the oleaginous microalga Monoraphidium neglectum, a biotechnologically promising microalga resistant to commonly applied lipid staining techniques. The lipid-specific CARS signal was successfully separated from the interfering two-photon excited fluorescence of chlorophyll and for the first time, lipid droplet formation during nitrogen starvation could directly be analysed. We found that the neutral lipid content deduced from CARS image analysis strongly correlated with the neutral lipid content measured gravimetrically and furthermore, that the relative degree of unsaturation of fatty acids stored in lipid droplets remained similar. Interestingly, the lipid profile during cellular adaption to nitrogen starvation showed a two-phase characteristic with initially fatty acid recycling and subsequent de novo lipid synthesis. This works demonstrates the potential of quantitative CARS microscopy as a label-free lipid analysis technique for any microalgal species, which is highly relevant for future biotechnological applications and to elucidate the process of microalgal lipid accumulation. PMID:27767024
Microfluidics and Raman microscopy: current applications and future challenges.
Chrimes, Adam F; Khoshmanesh, Khashayar; Stoddart, Paul R; Mitchell, Arnan; Kalantar-Zadeh, Kourosh
2013-07-07
Raman microscopy systems are becoming increasingly widespread and accessible for characterising chemical species. Microfluidic systems are also progressively finding their way into real world applications. Therefore, it is anticipated that the integration of Raman systems with microfluidics will become increasingly attractive and practical. This review aims to provide an overview of Raman microscopy-microfluidics integrated systems for researchers who are actively interested in utilising these tools. The fundamental principles and application strengths of Raman microscopy are discussed in the context of microfluidics. Various configurations of microfluidics that incorporate Raman microscopy methods are presented, with applications highlighted. Data analysis methods are discussed, with a focus on assisting the interpretation of Raman-microfluidics data from complex samples. Finally, possible future directions of Raman-microfluidic systems are presented.
Four-point bend apparatus for in situ micro-Raman stress measurements
NASA Astrophysics Data System (ADS)
Ward, Shawn H.; Mann, Adrian B.
2018-06-01
A device for in situ use with a micro-Raman microscope to determine stress from the Raman peak position was designed and validated. The device is a four-point bend machine with a micro-stepping motor and load cell, allowing for fine movement and accurate readings of the applied force. The machine has a small footprint and easily fits on most optical microscope stages. The results obtained from silicon are in good agreement with published literature values for the linear relationship between stress and peak position for the 520.8 cm‑1 Raman peak. The device was used to examine 4H–SiC and a good linear relationship was found between the 798 cm‑1 Raman peak position and stress, with the proportionality coefficient being close to the theoretical value of 0.0025. The 777 cm‑1 Raman peak also showed a linear dependence on stress, but the dependence was not as strong. The device examines both the tensile and compressive sides of the beam in bending, granting the potential for many materials and crystal orientations to be examined.
Raman Spectroscopy: A New Proposal for the Detection of Leukemia Using Blood Samples
NASA Astrophysics Data System (ADS)
Martínez-Espinosa, J. C.; González-Solís, J. L.; Frausto-Reyes, C.; Miranda-Beltrán, M. L.; Soria-Fregoso, C.; Medina-Valtierra, J.; Sánchez-Gómez, R.
2008-08-01
The use of Raman spectroscopy to analyze blood biochemistry and hence distinguish between normal and abnormal blood was investigated. The blood samples were obtained from 6 patients who were clinically diagnosed with leukemia and 6 healthy volunteer. The imprint was put under the microscope and several points were chosen for Raman measurement. All spectra were collected at confocal Raman micro-spectroscopy (Renishaw) with NIR 830 nm laser. It is shown that the serum samples from patients with leukemia and from the control group can be discriminated when the multivariate statistical methods of principal component analysis (PCA) and linear discriminated analysis (LDA) is applied to their Raman spectra. The ratios of some band intensities were analyzed and some band ratios were significant and corresponded to proteins, phospholipids, and polysaccharides. In addition, currently the degree of damage to the bone marrow is estimated through biopsies and therefore it is a very procedure painful. The preliminary results suggest that Raman spectroscopy could be a new technique to study the bone marrow using just blood samples.
NASA Astrophysics Data System (ADS)
Potcoava, Mariana C.; Futia, Gregory L.; Aughenbaugh, Jessica; Schlaepfer, Isabel R.; Gibson, Emily A.
2014-11-01
Increasing interest in the role of lipids in cancer cell proliferation and resistance to drug therapies has motivated the need to develop better tools for cellular lipid analysis. Quantification of lipids in cells is typically done by destructive chromatography protocols that do not provide spatial information on lipid distribution and prevent dynamic live cell studies. Methods that allow the analysis of lipid content in live cells are therefore of great importance. Using micro-Raman spectroscopy and coherent anti-Stokes Raman scattering (CARS) microscopy, we generated a lipid profile for breast (T47D, MDA-MB-231) and prostate (LNCaP, PC3) cancer cells upon exposure to medroxyprogesterone acetate (MPA) and synthetic androgen R1881. Combining Raman spectra with CARS imaging, we can study the process of hormone-mediated lipogenesis. Our results show that hormone-treated cancer cells T47D and LNCaP have an increased number and size of intracellular lipid droplets and higher degree of saturation than untreated cells. MDA-MB-231 and PC3 cancer cells showed no significant changes upon treatment. Principal component analysis with linear discriminant analysis of the Raman spectra was able to differentiate between cancer cells that were treated with MPA, R1881, and untreated.
Zhang, Guojin; Senak, Laurence; Moore, David J
2011-05-01
Spatially resolved infrared (IR) and Raman images are acquired from human hair cross sections or intact hair fibers. The full informational content of these spectra are spatially correlated to hair chemistry, anatomy, and structural organization through univariate and multivariate data analysis. Specific IR and Raman images from untreated human hair describing the spatial dependence of lipid and protein distribution, protein secondary structure, lipid chain conformational order, and distribution of disulfide cross-links in hair protein are presented in this study. Factor analysis of the image plane acquired with IR microscopy in hair sections, permits delineation of specific micro-regions within the hair. These data indicate that both IR and Raman imaging of molecular structural changes in a specific region of hair will prove to be valuable tools in the understanding of hair structure, physiology, and the effect of various stresses upon its integrity.
Gökce, Halil; Bahçeli, Semiha
2013-12-01
In this study, molecular geometries, experimental vibrational wavenumbers, electronic properties and quantum chemical calculations of 2-thiopheneglyoxylic acid molecule, (C6H4O3S), and its metal halides (Cd, Co, Cu, Ni and Zn) which are used as pharmacologic agents have been investigated experimentally by FT-IR, micro-Raman and UV-visible spectroscopies and elemental analysis. Meanwhile the vibrational calculations were verified by DFT/B3LYP method with 6-311++G(d,p) and LANL2DZ basis sets in the ground state, for free TPGA molecule and its metal halide complexes, respectively, for the first time. The calculated fundamental vibrational frequencies for the title compounds are in a good agreement with the experimental data. Copyright © 2013 Elsevier B.V. All rights reserved.
MicroRaman Spectroscopy and Raman Imaging of Basal Cell Carcinoma
NASA Astrophysics Data System (ADS)
Short, M. A.; Zeng, H.; Lui, H.
2005-03-01
We have measured the Raman spectra of normal and cancerous skin tissues using a confocal microRaman spectrograph with a sub-micron spatial resolution. We found that the Raman spectrum of a cell nucleolus is different from the spectra measured outside the nucleolus and considerably different from those measured outside the nucleus. In addition, we found significant spectroscopic differences between normal and cancer-bearing sites in the dermis region. In order to utilize these differences for non-invasive skin cancer diagnosis, we have developed a Raman imaging system that clearly demonstrates the structure, location and distribution of cells in unstained skin biopsy samples. Our method is expected to be useful for the detection and characterization of skin cancer based on the known distinct cellular differences between normal and malignant skin.
Allen, Christian Harry; Kumar, Achint; Qutob, Sami; Nyiri, Balazs; Chauhan, Vinita; Murugkar, Sangeeta
2018-01-09
Recent findings in populations exposed to ionizing radiation (IR) indicate dose-related lens opacification occurs at much lower doses (<2 Gy) than indicated in radiation protection guidelines. As a result, research efforts are now being directed towards identifying early predictors of lens degeneration resulting in cataractogenesis. In this study, Raman micro-spectroscopy was used to investigate the effects of varying doses of radiation, ranging from 0.01 Gy to 5 Gy, on human lens epithelial (HLE) cells which were chemically fixed 24 h post-irradiation. Raman spectra were acquired from the nucleus and cytoplasm of the HLE cells. Spectra were collected from points in a 3 × 3 grid pattern and then averaged. The raw spectra were preprocessed and principal component analysis followed by linear discriminant analysis was used to discriminate between dose and control for 0.25, 0.5, 2, and 5 Gy. Using leave-one-out cross-validation accuracies of greater than 74% were attained for each dose/control combination. The ultra-low doses 0.01 and 0.05 Gy were included in an analysis of band intensities for Raman bands found to be significant in the linear discrimination, and an induced repair model survival curve was fit to a band-difference-ratio plot of this data, suggesting HLE cells undergo a nonlinear response to low-doses of IR. A survival curve was also fit to clonogenic assay data done on the irradiated HLE cells, showing a similar nonlinear response.
NASA Astrophysics Data System (ADS)
Allen, Christian Harry; Kumar, Achint; Qutob, Sami; Nyiri, Balazs; Chauhan, Vinita; Murugkar, Sangeeta
2018-01-01
Recent findings in populations exposed to ionizing radiation (IR) indicate dose-related lens opacification occurs at much lower doses (<2 Gy) than indicated in radiation protection guidelines. As a result, research efforts are now being directed towards identifying early predictors of lens degeneration resulting in cataractogenesis. In this study, Raman micro-spectroscopy was used to investigate the effects of varying doses of radiation, ranging from 0.01 Gy to 5 Gy, on human lens epithelial (HLE) cells which were chemically fixed 24 h post-irradiation. Raman spectra were acquired from the nucleus and cytoplasm of the HLE cells. Spectra were collected from points in a 3 × 3 grid pattern and then averaged. The raw spectra were preprocessed and principal component analysis followed by linear discriminant analysis was used to discriminate between dose and control for 0.25, 0.5, 2, and 5 Gy. Using leave-one-out cross-validation accuracies of greater than 74% were attained for each dose/control combination. The ultra-low doses 0.01 and 0.05 Gy were included in an analysis of band intensities for Raman bands found to be significant in the linear discrimination, and an induced repair model survival curve was fit to a band-difference-ratio plot of this data, suggesting HLE cells undergo a nonlinear response to low-doses of IR. A survival curve was also fit to clonogenic assay data done on the irradiated HLE cells, showing a similar nonlinear response.
Scanning Angle Raman spectroscopy in polymer thin film characterization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nguyen, Vy H.T.
The focus of this thesis is the application of Raman spectroscopy for the characterization of thin polymer films. Chapter 1 provides background information and motivation, including the fundamentals of Raman spectroscopy for chemical analysis, scanning angle Raman scattering and scanning angle Raman scattering for applications in thin polymer film characterization. Chapter 2 represents a published manuscript that focuses on the application of scanning angle Raman spectroscopy for the analysis of submicron thin films with a description of methodology for measuring the film thickness and location of an interface between two polymer layers. Chapter 3 provides an outlook and future directionsmore » for the work outlined in this thesis. Appendix A, contains a published manuscript that outlines the use of Raman spectroscopy to aid in the synthesis of heterogeneous catalytic systems. Appendix B and C contain published manuscripts that set a foundation for the work presented in Chapter 2.« less
Progress towards broadband Raman quantum memory in Bose-Einstein condensates
NASA Astrophysics Data System (ADS)
Saglamyurek, Erhan; Hrushevskyi, Taras; Smith, Benjamin; Leblanc, Lindsay
2017-04-01
Optical quantum memories are building blocks for quantum information technologies. Efficient and long-lived storage in combination with high-speed (broadband) operation are key features required for practical applications. While the realization has been a great challenge, Raman memory in Bose-Einstein condensates (BECs) is a promising approach, due to negligible decoherence from diffusion and collisions that leads to seconds-scale memory times, high efficiency due to large atomic density, the possibility for atom-chip integration with micro photonics, and the suitability of the far off-resonant Raman approach with storage of broadband photons (over GHz) [5]. Here we report our progress towards Raman memory in a BEC. We describe our apparatus recently built for producing BEC with 87Rb atoms, and present the observation of nearly pure BEC with 5x105 atoms at 40 nK. After showing our initial characterizations, we discuss the suitability of our system for Raman-based light storage in our BEC.
Light trapping in thin-film solar cells measured by Raman spectroscopy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ledinský, M., E-mail: ledinsky@fzu.cz; Photovoltaics and Thin Film Electronics Laboratory, Institute of Microengineering; Moulin, E.
2014-09-15
In this study, Raman spectroscopy is used as a tool to determine the light-trapping capability of textured ZnO front electrodes implemented in microcrystalline silicon (μc-Si:H) solar cells. Microcrystalline silicon films deposited on superstrates of various roughnesses are characterized by Raman micro-spectroscopy at excitation wavelengths of 442 nm, 514 nm, 633 nm, and 785 nm, respectively. The way to measure quantitatively and with a high level of reproducibility the Raman intensity is described in details. By varying the superstrate texture and with it the light trapping in the μc-Si:H absorber layer, we find significant differences in the absolute Raman intensity measured in the near infraredmore » wavelength region (where light trapping is relevant). A good agreement between the absolute Raman intensity and the external quantum efficiency of the μc-Si:H solar cells is obtained, demonstrating the validity of the introduced method. Applications to thin-film solar cells, in general, and other optoelectronic devices are discussed.« less
Li, Q H; Yang, J C; Li, L; Dong, J Q; Zhao, H X; Liu, S
2015-03-05
This article describes the complementary application of non-invasive micro-Raman spectroscopy and energy dispersive X-ray fluorescence spectrometry to the characterization of some ancient Chinese silicate artifacts. A total of 28 samples dated from fourth century BC to third century AD were analyzed. The results of chemical analysis showed that the vitreous PbO-BaO-SiO2 material was used to sinter these silicate artifacts. The barium copper silicate pigments including BaCuSi4O10, BaCuSi2O6 and BaCu2Si2O7 were widely identified from colorful areas of the samples by Raman spectroscopy. In addition, other crystalline phases such as Fe2O3, BaSi2O5, BaSO4, PbCO3 and quartz were also identified. The present study provides very valuable information to trace the technical evolution of man-made barium copper silicate pigments and their close relationship with the making of ancient PbO-BaO-SiO2 glaze and glass. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Li, Q. H.; Yang, J. C.; Li, L.; Dong, J. Q.; Zhao, H. X.; Liu, S.
2015-03-01
This article describes the complementary application of non-invasive micro-Raman spectroscopy and energy dispersive X-ray fluorescence spectrometry to the characterization of some ancient Chinese silicate artifacts. A total of 28 samples dated from fourth century BC to third century AD were analyzed. The results of chemical analysis showed that the vitreous PbO-BaO-SiO2 material was used to sinter these silicate artifacts. The barium copper silicate pigments including BaCuSi4O10, BaCuSi2O6 and BaCu2Si2O7 were widely identified from colorful areas of the samples by Raman spectroscopy. In addition, other crystalline phases such as Fe2O3, BaSi2O5, BaSO4, PbCO3 and quartz were also identified. The present study provides very valuable information to trace the technical evolution of man-made barium copper silicate pigments and their close relationship with the making of ancient PbO-BaO-SiO2 glaze and glass.
Geiman, Irina; Leona, Marco; Lombardi, John R
2009-07-01
The applicability of Raman spectroscopy and surface-enhanced Raman scattering (SERS) to the analysis of synthetic dyes commonly found in ballpoint inks was investigated in a comparative study. Spectra of 10 dyes were obtained using a dispersive system (633 nm, 785 nm lasers) and a Fourier transform system (1064 nm laser) under different analytical conditions (e.g., powdered pigments, solutions, thin layer chromatography [TLC] spots). While high fluorescence background and poor spectral quality often characterized the normal Raman spectra of the dyes studied, SERS was found to be generally helpful. Additionally, dye standards and a single ballpoint ink were developed on a TLC plate following a typical ink analysis procedure. SERS spectra were successfully collected directly from the TLC plate, thus demonstrating a possible forensic application for the technique.
In-SITU, Time-resolved Raman Spectro-micro-topography of an Operating Lithium Ion Battery
NASA Technical Reports Server (NTRS)
Luo, Yu; Cai, Wen-Bin; Xing, Xue-Kun; Scherson, Daniel A.
2003-01-01
A Raman microscope has been coupled to a computer-controlled, two-dimensional linear translator attached to a custom-designed, sealed optical chamber to allow in situ acquisition of space-, and time-resolved spectra of an operating thin graphite/LiCoO2 Li-ion battery. This unique arrangement made it possible to collect continuously series of Raman spectra from a sharply defined edge of the battery exposing the anode (A), separator (S), and cathode (C), during charge and discharge, while the device was moved back and forth under the fixed focused laser beam along an axis normal to the layered A/S/C plane. Clear spectral evidence was obtained for changes in the amount of Li(+) within particles of graphite in the anode, and, to a lesser extent, of LiCoO2 in the cathode, during battery discharge both as a function of position and time. Analysis of time-resolved Raman spectro-micro-topography (SMT) measurements of the type described in this work are expected to open new prospects for assessing the validity of theoretical models aimed at simulating the flow of Li(+) within Li-ion batteries under operating conditions.
REMOTE RAMAN SPECTROSCOPY OF VARIOUS MIXED AND COMPOSITE MINERAL PHASES AT 7.2 m DISTANCE
NASA Technical Reports Server (NTRS)
Sharma, S. K.; Misra, A. K.; Ismail, Syed; Singh, U. N.
2006-01-01
Remote Raman [e.g.,1-5] and micro-Raman spectroscopy [e.g., 6-10] are being evaluated on geological samples for their potential applications on Mars rover or lander. The Raman lines of minerals are sharp and distinct. The Raman finger-prints of minerals do not shift appreciably but remain distinct even in sub-micron grains and, therefore, can be used for mineral identification in fine-grained rocks [e.g., 4,7]. In this work we have evaluated the capability of a directly coupled remote Raman system (co-axial configuration) for distinguishing the mineralogy of multiple crystals in the exciting laser beam. We have measured the Raman spectra of minerals in the near vicinity of each other and excited with a laser beam (e.g. -quartz (Qz) and K-feldspar (Feld) plates, each 5 mm thick). The spectra of composite transparent mineral plates of 5 mm thickness of -quartz and gypsum over calcite crystal were measured with the composite samples perpendicular to the exciting laser beam. The measurements of remote Raman spectra of various bulk minerals, and mixed and composite minerals with our portable UH remote Raman system were carried out at the Langley Research Center in a fully illuminated laboratory.
Facile fabrication of microfluidic surface-enhanced Raman scattering devices via lift-up lithography
NASA Astrophysics Data System (ADS)
Wu, Yuanzi; Jiang, Ye; Zheng, Xiaoshan; Jia, Shasha; Zhu, Zhi; Ren, Bin; Ma, Hongwei
2018-04-01
We describe a facile and low-cost approach for a flexibly integrated surface-enhanced Raman scattering (SERS) substrate in microfluidic chips. Briefly, a SERS substrate was fabricated by the electrostatic assembling of gold nanoparticles, and shaped into designed patterns by subsequent lift-up soft lithography. The SERS micro-pattern could be further integrated within microfluidic channels conveniently. The resulting microfluidic SERS chip allowed ultrasensitive in situ SERS monitoring from the transparent glass window. With its advantages in simplicity, functionality and cost-effectiveness, this method could be readily expanded into optical microfluidic fabrication for biochemical applications.
Principles and applications of Raman spectroscopy in pharmaceutical drug discovery and development.
Gala, Urvi; Chauhan, Harsh
2015-02-01
In recent years, Raman spectroscopy has become increasingly important as an analytical technique in various scientific areas of research and development. This is partly due to the technological advancements in Raman instrumentation and partly due to detailed fingerprinting that can be derived from Raman spectra. Its versatility of applications, rapidness of collection and easy analysis have made Raman spectroscopy an attractive analytical tool. The following review describes Raman spectroscopy and its application within the pharmaceutical industry. The authors explain the theory of Raman scattering and its variations in Raman spectroscopy. The authors also highlight how Raman spectra are interpreted, providing examples. Raman spectroscopy has a number of potential applications within drug discovery and development. It can be used to estimate the molecular activity of drugs and to establish a drug's physicochemical properties such as its partition coefficient. It can also be used in compatibility studies during the drug formulation process. Raman spectroscopy's immense potential should be further investigated in future.
Chen, Shan; Li, Xiao-ning; Liang, Yi-zeng; Zhang, Zhi-min; Liu, Zhao-xia; Zhang, Qi-ming; Ding, Li-xia; Ye, Fei
2010-08-01
During Raman spectroscopy analysis, the organic molecules and contaminations will obscure or swamp Raman signals. The present study starts from Raman spectra of prednisone acetate tablets and glibenclamide tables, which are acquired from the BWTek i-Raman spectrometer. The background is corrected by R package baselineWavelet. Then principle component analysis and random forests are used to perform clustering analysis. Through analyzing the Raman spectra of two medicines, the accurate and validity of this background-correction algorithm is checked and the influences of fluorescence background on Raman spectra clustering analysis is discussed. Thus, it is concluded that it is important to correct fluorescence background for further analysis, and an effective background correction solution is provided for clustering or other analysis.
Raman microspectroscopy of optically trapped micro- and nanoobjects
NASA Astrophysics Data System (ADS)
Jonáš, Alexandr; Ježek, Jan; Šerý, Mojmír; Zemánek, Pavel
2008-12-01
We describe and characterize an experimental system for Raman microspectroscopy of micro- and nanoobjects optically trapped in aqueous suspensions with the use of a single-beam gradient optical trap (Raman tweezers). This system features two separate lasers providing light for the optical trapping and excitation of the Raman scattering spectra from the trapped specimen, respectively. Using independent laser beams for trapping and spectroscopy enables optimizing the parameters of both beams for their respective purposes. Moreover, it is possible to modulate the position of the trapped object relative to the Raman beam focus for maximizing the detected Raman signal and obtaining spatially resolved images of the trapped specimen. Using this experimental system, we have obtained Raman scattering spectra of individual optically confined micron and sub-micron sized polystyrene beads and baker's yeast cells. Sufficiently high signal-to-noise ratio of the spectra could be achieved using a few tens of milliwatts of the Raman beam power and detector integration times on the order of seconds.
Raman chemical imaging technology for food and agricultural applications
USDA-ARS?s Scientific Manuscript database
This paper presents Raman chemical imaging technology for inspecting food and agricultural products. The paper puts emphasis on introducing and demonstrating Raman imaging techniques for practical uses in food analysis. The main topics include Raman scattering principles, Raman spectroscopy measurem...
NASA Technical Reports Server (NTRS)
Chan, Q. H. S.; Zolensky, M. E.; Bodnar, R. J.; Kebukawa, Y.
2015-01-01
Graphitization of carbon is an irreversible process which alters the structure of graphitic materials in response to the increase in metamorphic grade (temperature and/or pressure). Carbonaceous materials offer a reliable geothermometer as their Raman spectra change systematically with increasing metamorphic grade. In this study, we identified carbonaceous materials in the xenolithic clasts in Sharps and interpreted their metamorphic history by revealing the structural organization (order) of the polyaromatic organic phases using micro-Raman spectroscopy.
Near-ultraviolet micro-Raman study of diamond grown on GaN
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nazari, M., E-mail: m-n79@txstate.edu; Hancock, B. L.; Anderson, J.
2016-01-18
Ultraviolet (UV) micro-Raman measurements are reported of diamond grown on GaN using chemical vapor deposition. UV excitation permits simultaneous investigation of the diamond (D) and disordered carbon (DC) comprising the polycrystalline layer. From line scans of a cross-section along the diamond growth direction, the DC component of the diamond layer is found to be highest near the GaN-on-diamond interface and diminish with characteristic length scale of ∼3.5 μm. Transmission electron microscopy (TEM) of the diamond near the interface confirms the presence of DC. Combined micro-Raman and TEM are used to develop an optical method for estimating the DC volume fraction.
Investigation of domain walls in PPLN by confocal raman microscopy and PCA analysis
NASA Astrophysics Data System (ADS)
Shur, Vladimir Ya.; Zelenovskiy, Pavel; Bourson, Patrice
2017-07-01
Confocal Raman microscopy (CRM) is a powerful tool for investigation of ferroelectric domains. Mechanical stresses and electric fields existed in the vicinity of neutral and charged domain walls modify frequency, intensity and width of spectral lines [1], thus allowing to visualize micro- and nanodomain structures both at the surface and in the bulk of the crystal [2,3]. Stresses and fields are naturally coupled in ferroelectrics due to inverse piezoelectric effect and hardly can be separated in Raman spectra. PCA is a powerful statistical method for analysis of large data matrix providing a set of orthogonal variables, called principal components (PCs). PCA is widely used for classification of experimental data, for example, in crystallization experiments, for detection of small amounts of components in solid mixtures etc. [4,5]. In Raman spectroscopy PCA was applied for analysis of phase transitions and provided critical pressure with good accuracy [6]. In the present work we for the first time applied Principal Component Analysis (PCA) method for analysis of Raman spectra measured in periodically poled lithium niobate (PPLN). We found that principal components demonstrate different sensitivity to mechanical stresses and electric fields in the vicinity of the domain walls. This allowed us to separately visualize spatial distribution of fields and electric fields at the surface and in the bulk of PPLN.
Rapid detection of bacterial contamination in cell or tissue cultures based on Raman spectroscopy
NASA Astrophysics Data System (ADS)
Bolwien, Carsten; Sulz, Gerd; Becker, Sebastian; Thielecke, Hagen; Mertsching, Heike; Koch, Steffen
2008-02-01
Monitoring the sterility of cell or tissue cultures is an essential task, particularly in the fields of regenerative medicine and tissue engineering when implanting cells into the human body. We present a system based on a commercially available microscope equipped with a microfluidic cell that prepares the particles found in the solution for analysis, a Raman-spectrometer attachment optimized for non-destructive, rapid recording of Raman spectra, and a data acquisition and analysis tool for identification of the particles. In contrast to conventional sterility testing in which samples are incubated over weeks, our system is able to analyze milliliters of supernatant or cell suspension within hours by filtering relevant particles and placing them on a Raman-friendly substrate in the microfluidic cell. Identification of critical particles via microscopic imaging and subsequent image analysis is carried out before micro-Raman analysis of those particles is then carried out with an excitation wavelength of 785 nm. The potential of this setup is demonstrated by results of artificial contamination of samples with a pool of bacteria, fungi, and spores: single-channel spectra of the critical particles are automatically baseline-corrected without using background data and classified via hierarchical cluster analysis, showing great promise for accurate and rapid detection and identification of contaminants.
Raman Imaging in Cell Membranes, Lipid-Rich Organelles, and Lipid Bilayers.
Syed, Aleem; Smith, Emily A
2017-06-12
Raman-based optical imaging is a promising analytical tool for noninvasive, label-free chemical imaging of lipid bilayers and cellular membranes. Imaging using spontaneous Raman scattering suffers from a low intensity that hinders its use in some cellular applications. However, developments in coherent Raman imaging, surface-enhanced Raman imaging, and tip-enhanced Raman imaging have enabled video-rate imaging, excellent detection limits, and nanometer spatial resolution, respectively. After a brief introduction to these commonly used Raman imaging techniques for cell membrane studies, this review discusses selected applications of these modalities for chemical imaging of membrane proteins and lipids. Finally, recent developments in chemical tags for Raman imaging and their applications in the analysis of selected cell membrane components are summarized. Ongoing developments toward improving the temporal and spatial resolution of Raman imaging and small-molecule tags with strong Raman scattering cross sections continue to expand the utility of Raman imaging for diverse cell membrane studies.
Bersani, D; Salvioli-Mariani, E; Mattioli, M; Menichetti, M; Lottici, P P
2009-08-01
Fluid inclusions in the quartz crystals present in gold-rich veins from central Honduras have been studied by means of micro-thermometry and micro-Raman spectroscopy in order to provide information on the physico-chemical conditions and chemical composition of the mineralizing fluids. The use of a confocal micro-Raman apparatus allowed to obtain information on the fluid composition, in particular on the gas phase, minimizing the contributions of the host matrix to the Raman signal. The samples studied were collected from an area (Lepaguare mining district, Northern-Central Honduras) rich in ore deposits due to the Cenozoic magmatic activity, where the gold and sulphide mineralization is connected with a system of quartz veins (few decimetres thick) occurring in low-grade metamorphic rocks and produced by hydrothermal fluids. The quartz crystals present in the gold-rich veins often contain fluid inclusions. Four types of fluid inclusions have been observed, but their assemblage in the same clusters and fracture systems, as well as their comparable salinity and homogenization data, suggest that they have the same origin. Micro-thermometry and Raman spectroscopy provide a composition of the mineralizing fluids attributable to the system H(2)O-NaCl-KCl-CO(2)-CH(4), with temperature and pressure intervals of 210-413 degrees C and 1050-3850 bar, respectively. These data agree with an epigenetic origin of the gold deposit (depth < 6 km) related to granitoid or granodiorite intrusions associated to orogenic environments.
Applications of spatially offset Raman spectroscopy to defense and security
NASA Astrophysics Data System (ADS)
Guicheteau, Jason; Hopkins, Rebecca
2016-05-01
Spatially offset Raman spectroscopy (SORS) allows for sub-surface and through barrier detection and has applications in drug analysis, cancer detection, forensic science, as well as defense and security. This paper reviews previous efforts in SORS and other through barrier Raman techniques and presents a discussion on current research in defense and security applications.
NASA Astrophysics Data System (ADS)
Liu, Xi; Huang, Meizhen; Chen, Jie; Kong, Lili; Wang, Keihui
2018-05-01
A simple method, based on a roll-to-roll ultraviolet micro-pyramid imprinting technique and a nanoparticle self-assembling process in aqueous solution, to fabricate a large-area, flexible surface-enhanced Raman scattering (SERS) polyethylene glycol terephthalate substrate is proposed. The SERS substrate is demonstrated to be of high sensitivity. The detection concentration of Rhodamine 6G (R6G) measured by a portable Raman spectrometer is down to 10-9 mol l-1. The relative standard deviation values of different spots and different substrates are less than 13%. In addition, the feasibility for rapid detection of dye in herbal tea based on this SERS substrate and a portable Raman spectrometer is investigated. Three industrial dyes are employed to simulate the dyeing process. It is presented that R6G of 4.8× {{10}-7} g ml-1, malachite green of 10-6 g ml-1 and Auramine O of 10-6 g ml-1 in herbal tea could be detected rapidly. The experimental results imply that this method could be potentially applied in the field of dyed herbal tea detection.
Synthesis and characterization of covalent diphenylalanine nanotube-folic acid conjugates
NASA Astrophysics Data System (ADS)
Castillo, John J.; Rindzevicius, Tomas; Wu, Kaiyu; Schmidt, Michael S.; Janik, Katarzyna A.; Boisen, Anja; Svendsen, Winnie; Rozlosnik, Noemi; Castillo-León, Jaime
2014-07-01
Herein, we describe the synthesis and characterization of a covalent nanoscale assembly formed between diphenylalanine micro/nanotubes (PNT) and folic acid (FA). The conjugate was obtained via chemical functionalization through coupling of amine groups of PNTs and carboxylic groups of FA. The surface analysis of PNT-FA indicated the presence of FA aggregates on the surface of PNTs. The covalent interaction between FA and self-assembled PNTs was further investigated using fluorescence microscopy, Raman and surface-enhanced Raman scattering (SERS) spectroscopies. The SERS experiments were performed on a large area silver-capped (diameter of 62 nm) silicon nanopillars with an approximate height of 400 nm and a width of 200 nm. The results showed that the PNT-FA synthesis procedure preserves the molecular structure of FA. The PNT-FA conjugate presented in this study is a promising candidate for applications in the detection and diagnosis of cancer or tropical diseases such as leishmaniasis and as a carrier nanosystem delivering drugs to malignant tumors that overexpress folate receptors.
Characterization of N-doped multilayer graphene grown on 4H-SiC (0001)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arezki, Hakim, E-mail: hakim.arezki@lgep.supelec.fr; Jaffré, Alexandre; Alamarguy, David
Large-area graphene film doped with hetero-atoms is of great interest for a wide spectrum of nanoelectronics applications, such as field effect devices, super capacitors, fuel cells among many others. Here, we report the structural and electronic properties of nitrogen doped multilayer graphene on 4H-SiC (0001). The incorporation of nitrogen during the growth causes an increase in the D band on the Raman signature indicating that the nitrogen is creating defects. The analysis of micro-Raman mapping of G, D, 2D bands shows a predominantly trilayer graphene with a D band inherent to doping and inhomogeneous dopant distribution at the step edges.more » Ultraviolet photoelectron spectroscopy (UPS) indicates an n type work function (WF) of 4.1 eV. In addition, a top gate FET device was fabricated showing n-type I-V characteristic after the desorption of oxygen with high electron and holes mobilities.« less
Depth Profiling of SiC Lattice Damage Using Micro-Raman Spectroscopy
2002-01-01
can significantly change the electric behavior. Techniques like Positron Annihilation Spectroscopy [5,6] and Rutherford Backscattering/Channeling... Semiconductor Materials for Optoelectronic Applications Symposium held in Boston, Massachusetts on November 26-29, 2001. To order the complete compilation... Spectroscopy DISTRIBUTION: Approved for public release, distribution unlimited This paper is part of the following report: TITLE: Progress in
Liu, Chang-Ling; Ye, Yu-Guang; Meng, Qing-Guo; Lü, Wan-Jun; Wang, Fei-Fei
2011-06-01
Micro laser Raman spectroscopic technique was used for in situ observation of the micro-processes of methane hydrate formed and decomposed in a high pressure transparent capillary. The changes in clathrate structure of methane hydrate were investigated during these processes. The results show that, during hydrate formation, the Raman peak (2 917 cm(-1)) of methane gas gradually splits into two peaks (2 905 and 2 915 cm(-1)) representing large and small cages, respectively, suggesting that the dissolved methane molecules go into two different chemical environments. In the meantime, the hydrogen bonds interaction is strengthened because water is changing from liquid to solid state gradually. As a result, the O-H stretching vibrations of water shift to lower wavenumber. During the decomposition process of methane hydrates, the Raman peaks of the methane molecules both in the large and small cages gradually clear up, and finally turn into a single peak of methane gas. The experimental results show that laser Raman spectroscopy can accurately demonstrate some relevant information of hydrate crystal structure changes during the formation and dissociation processes of methane hydrate.
NASA Astrophysics Data System (ADS)
Blacksberg, J.; Alerstam, E.; Maruyama, Y.; Cochrane, C.; Rossman, G. R.
2016-12-01
Raman spectroscopy combined with microscopic imaging is a powerful technique used to interrogate geological materials. In the laboratory, Raman spectroscopy is commonly used in the geosciences for mapping both major and minor mineral and organic constituents on a fine scale. This technique has proven valuable in analyzing planetary materials, including meteorites and lunar samples. By simultaneously analyzing microtexture and mineralogy, micro-Raman spectroscopy can provide essential information for inferring geologic processes by which planetary surfaces have evolved. Because Raman can perform these capabilities in a way that is non-destructive, requiring no sample preparation, it is extremely well suited for deployment on a planetary lander or rover arm. The pulsed Raman spectrometer presented here has been designed for maximum flexibility using miniaturized modular components in order to remain easily adaptable and relevant to numerous planetary surface missions (e.g. asteroids, comets, Mars, Mars' moons, Europa, Titan). Building on the widely used 532 nm laser Raman technique, the pulsed Raman spectrometer takes advantage of recent developments in miniaturized pulsed lasers and detectors; the instrument uses sub-ns time gating to remove pervasive background interference caused by fluorescence inherent in many minerals and organics. This technique ensures acquisition of diagnostic Raman spectra, even in environments that have been known to severely challenge conventional methods (e.g. aqueously-formed minerals from similar environments on Earth). We present the architecture and performance of the pulsed Raman spectrometer, which relies on our single photon avalanche diode (SPAD) detector synchronized with our high-speed microchip laser, both custom-built for this application. It is these key technological developments that now make time-gated Raman spectroscopy possible for applications where miniaturization is crucial. We then discuss recent progress in laser performance that enhances Raman return, provides improved fluorescence rejection, and minimizes damage to sensitive samples.
A pulsed single-frequency Nd:GGG/BaWO4 Raman laser
NASA Astrophysics Data System (ADS)
Liu, Zhaojun; Men, Shaojie; Cong, Zhenhua; Qin, Zengguang; Zhang, Xingyu; Zhang, Huaijin
2018-04-01
A single-frequency pulsed laser at 1178.3 nm was demonstrated in a crystalline Raman laser. A crystal combination of Nd:GGG and BaWO4 was selected to realize Raman conversion from a 1062.5 nm fundamental wave to a 1178.3 nm Stokes wave. An entangled cavity was specially designed to form an intracavity Raman configuration. Single-longitudinal-mode operation was realized by introducing two Fabry-Perot etalons into the Raman laser cavity. This laser operated at a pulse repetition rate of 50 Hz with 2 ms long envelopes containing micro pulses at a 30 kHz repetition rate. The highest output power was 41 mW with the micro pulse duration of 15 ns. The linewidth was measured to be less than 130 MHz.
NASA Astrophysics Data System (ADS)
Holakooei, Parviz; Karimy, Amir-Hossein; Hasanpour, Ata; Oudbashi, Omid
2016-12-01
This paper reports the results of studies performed on a painted stucco fragment excavated at the Ghaleh Guri in Ramavand, western Iran, and dated back to the late Sasanian period (224-651 AD). Analytical studies including micro-Raman spectroscopy (μ-Raman), micro-X-ray spectrometry (μ-XRF) and optical microscopy showed that red lead and vermilion were used as main pigments on this fragment. Moreover, carbon black was diagnosed to thinly cover some parts of the red lead. Peculiarly, wulfenite (PbMoO4) associated with vanadinite (Pb5(VO4)3Cl) was identified to compose a yellow stain sporadically dispersed on the other pigments.
Perez-Rodriguez, Jose Luis; Robador, Maria Dolores; Centeno, Miguel Angel; Siguenza, Belinda; Duran, Adrian
2014-01-01
This work describes a comparative study between in situ applications of portable Raman spectroscopy and direct laboratory measurements using micro-Raman spectroscopy on the surface of small samples and of cross sections. The study was performed using wall paintings from different sites of the Alcazar of Seville. Little information was obtained using a portable Raman spectrometer due to the presence of an acrylic polymer, calcium oxalate, calcite and gypsum that was formed or deposited on the surface. The pigments responsible for different colours, except cinnabar, were not detected by the micro-Raman spectroscopy study of the surface of small samples taken from the wall paintings due to the presence of surface contaminants. The pigments and plaster were characterised using cross sections. The black colour consisted of carbon black. The red layers were formed by cinnabar and white lead or by iron oxides. The green and white colours were composed of green emerald or atacamite and calcite, respectively. Pb3O4 has also been characterised. The white layers (plaster) located under the colour layers consisted of calcite, quartz and feldspars. The fresco technique was used to create the wall paintings. A wall painting located on a gypsum layer was also studied. The Naples yellow in this wall painting was not characterised due to the presence of glue and oils. This study showed the advantage of studying cross sections to completely characterise the pigments and plaster in the studied wall paintings. Copyright © 2013 Elsevier B.V. All rights reserved.
Micro and nano liposome vesicles containing curcumin for a drug delivery system
NASA Astrophysics Data System (ADS)
Nguyen, Tuan Anh; Duoc Tang, Quan; Chanh Tin Doan, Duc; Chien Dang, Mau
2016-09-01
Micro and nano liposome vesicles were prepared using a lipid film hydration method and a sonication method. Phospholipid, cholesterol and curcumin were used to form micro and nano liposomes containing curcumin. The size, structure and properties of the liposomes were characterized by using optical microscopy, transmission electron microscopy, and UV-vis and Raman spectroscopy. It was found that the size of the liposomes was dependent on their composition and the preparation method. The hydration method created micro multilamellars, whereas nano unilamellars were formed using the sonication method. By adding cholesterol, the vesicles of the liposome could be stabilized and stored at 4 °C for up to 9 months. The liposome vesicles containing curcumin with good biocompatibility and biodegradability could be used for drug delivery applications.
Recent advances in the application of transmission Raman spectroscopy to pharmaceutical analysis.
Buckley, Kevin; Matousek, Pavel
2011-06-25
This article reviews recent advances in transmission Raman spectroscopy and its applications, from the perspective of pharmaceutical analysis. The emerging concepts enable rapid non-invasive volumetric analysis of pharmaceutical formulations and could lead to many important applications in pharmaceutical settings, including quantitative bulk analysis of intact pharmaceutical tablets and capsules in quality and process control. Crown Copyright © 2010. Published by Elsevier B.V. All rights reserved.
Guerain, Mathieu; Grosseau-Poussard, Jean-Luc; Geandier, Guillaume; ...
2017-11-21
In oxidizing environments, the protection of metals and alloys against further oxidation at high temperature is provided by the oxide film itself. This protection is efficient only if the formed film adheres well to the metal (substrate), i.e., without microcracks and spalls induced by thermomechanical stresses. In this study, the residual stresses at both macroscopic and microscopic scales in the oxide film adhering to the substrate and over the damaged areas have been rigorously determined on the same samples for both techniques. Ni-30Cr and Fe-47Cr alloys have been oxidized together at 900 and 1000 °C, respectively, to create films withmore » a thickness of a few microns. A multi-scale approach was adopted: macroscopic stress was determined by conventional X-ray diffraction and Raman spectroscopy, while microscopic residual stress mappings were performed over different types of bucklings using Raman micro-spectroscopy and synchrotron micro-diffraction. A very good agreement is found at macro- and microscales between the residual stress values obtained with both techniques, giving confidence on the reliability of the measurements. In addition, relevant structural information at the interface between the metallic substrate and the oxide layer was collected by micro-diffraction, a non-destructive technique that allows mapping through the oxide layer, and both the grain size and the crystallographic orientation of the supporting polycrystalline metal located either under a buckling or not were measured.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guerain, Mathieu; Grosseau-Poussard, Jean-Luc; Geandier, Guillaume
In oxidizing environments, the protection of metals and alloys against further oxidation at high temperature is provided by the oxide film itself. This protection is efficient only if the formed film adheres well to the metal (substrate), i.e., without microcracks and spalls induced by thermomechanical stresses. In this study, the residual stresses at both macroscopic and microscopic scales in the oxide film adhering to the substrate and over the damaged areas have been rigorously determined on the same samples for both techniques. Ni-30Cr and Fe-47Cr alloys have been oxidized together at 900 and 1000 °C, respectively, to create films withmore » a thickness of a few microns. A multi-scale approach was adopted: macroscopic stress was determined by conventional X-ray diffraction and Raman spectroscopy, while microscopic residual stress mappings were performed over different types of bucklings using Raman micro-spectroscopy and synchrotron micro-diffraction. A very good agreement is found at macro- and microscales between the residual stress values obtained with both techniques, giving confidence on the reliability of the measurements. In addition, relevant structural information at the interface between the metallic substrate and the oxide layer was collected by micro-diffraction, a non-destructive technique that allows mapping through the oxide layer, and both the grain size and the crystallographic orientation of the supporting polycrystalline metal located either under a buckling or not were measured.« less
NASA Astrophysics Data System (ADS)
Guerain, Mathieu; Grosseau-Poussard, Jean-Luc; Geandier, Guillaume; Panicaud, Benoit; Tamura, Nobumichi; Kunz, Martin; Dejoie, Catherine; Micha, Jean-Sebastien; Thiaudière, Dominique; Goudeau, Philippe
2017-11-01
In oxidizing environments, the protection of metals and alloys against further oxidation at high temperature is provided by the oxide film itself. This protection is efficient only if the formed film adheres well to the metal (substrate), i.e., without microcracks and spalls induced by thermomechanical stresses. In this study, the residual stresses at both macroscopic and microscopic scales in the oxide film adhering to the substrate and over the damaged areas have been rigorously determined on the same samples for both techniques. Ni-30Cr and Fe-47Cr alloys have been oxidized together at 900 and 1000 °C, respectively, to create films with a thickness of a few microns. A multi-scale approach was adopted: macroscopic stress was determined by conventional X-ray diffraction and Raman spectroscopy, while microscopic residual stress mappings were performed over different types of bucklings using Raman micro-spectroscopy and synchrotron micro-diffraction. A very good agreement is found at macro- and microscales between the residual stress values obtained with both techniques, giving confidence on the reliability of the measurements. In addition, relevant structural information at the interface between the metallic substrate and the oxide layer was collected by micro-diffraction, a non-destructive technique that allows mapping through the oxide layer, and both the grain size and the crystallographic orientation of the supporting polycrystalline metal located either under a buckling or not were measured.
Micro-Raman spectroscopy of tissue samples for oral pathology follow-up monitoring
NASA Astrophysics Data System (ADS)
Delfino, I.; Camerlingo, C.; Zenone, F.; Perna, G.; Capozzi, V.; Cirillo, N.; Gaeta, G. M.; Lepore, M.
2010-04-01
An "in vitro" study of Raman spectra from oral human tissues is reported in order to the develop a diagnostic method suitable for "in vivo" oral pathology follow-up. The investigated pathology is Pemphigus Vulgaris (PV) for which new techniques for guiding and monitoring therapy would be particularly useful. Raman spectra were obtained in the wavenumber regions from 1000 to 1800 cm-1 and 2700 to 3200 cm-1 from tissues from patients at different stages of pathology (active PV, under therapy and in PV remission stage) as confirmed by histopathological and immunofluorescence analysis. Differences in the spectra depending on tissue illness stage arise in 1150-1250 cm-1 (amide III) and 1420-1450 cm-1 (CH3 deformation) regions and around 1650 cm-1 (amide I) and 2930 cm-1 (CH3 symmetric stretch). A wavelet deconvolution procedure was applied to the spectra for better discriminating among the three different stages of illness and a linear regression analysis was used to fully exploit the content of information of Raman spectra.
Comparison between infrared and Raman spectroscopic analysis of maturing rabbit cortical bone.
Turunen, Mikael J; Saarakkala, Simo; Rieppo, Lassi; Helminen, Heikki J; Jurvelin, Jukka S; Isaksson, Hanna
2011-06-01
The molecular composition of the organic and inorganic matrices of bone undergoes alterations during maturation. The aim of this study was to compare Fourier transform infrared (FT-IR) and near-infrared (NIR) Raman microspectroscopy techniques for characterization of the composition of growing and developing bone from young to skeletally mature rabbits. Moreover, the specificity and differences of the techniques for determining bone composition were clarified. The humeri of female New Zealand White rabbits, with age range from young to skeletally mature animals (four age groups, n = 7 per group), were studied. Spectral peak areas, intensities, and ratios related to organic and inorganic matrices of bone were analyzed and compared between the age groups and between FT-IR and Raman microspectroscopic techniques. Specifically, the degree of mineralization, type-B carbonate substitution, crystallinity of hydroxyapatite (HA), mineral content, and collagen maturity were examined. Significant changes during maturation were observed in various compositional parameters with one or both techniques. Overall, the compositional parameters calculated from the Raman spectra correlated with analogous parameters calculated from the IR spectra. Collagen cross-linking (XLR), as determined through peak fitting and directly from the IR spectra, were highly correlated. The mineral/matrix ratio in the Raman spectra was evaluated with multiple different peaks representing the organic matrix. The results showed high correlation with each other. After comparison with the bone mineral density (BMD) values from micro-computed tomography (micro-CT) imaging measurements and crystal size from XRD measurements, it is suggested that Raman microspectroscopy is more sensitive than FT-IR microspectroscopy for the inorganic matrix of the bone. In the literature, similar spectroscopic parameters obtained with FT-IR and NIR Raman microspectroscopic techniques are often compared. According to the present results, however, caution is required when performing this kind of comparison.
Raman analysis of cobalt blue pigment in blue and white porcelain: A reassessment.
Jiang, Xiaochenyang; Ma, Yanying; Chen, Yue; Li, Yuanqiu; Ma, Qinglin; Zhang, Zhaoxia; Wang, Changsui; Yang, Yimin
2018-02-05
Cobalt blue is a famous pigment in human history. In the past decade it is widely reported that the cobalt aluminate has been detected in ancient ceramics as blue colorant in glaze, yet the acquired Raman spectra are incredibly different from that of synthesised references, necessitating a reassessment of such contradictory scenario with more accurate analytic strategies. In this study, micro-Raman spectroscopy (MRS) and scanning electron microscopy (SEM) in association with energy dispersive spectrometry (EDS) were performed on under-glaze cobalt pigments from one submerged blue and white porcelain shard dated from Wanli reign (1573-1620CE) of Ming dynasty (1365-1644CE) excavated at Nan'ao I shipwreck off the southern coast of China. The micro-structural inspection reveals that the pigment particles have characteristics of small account, tiny size, heterogeneously distribution, and more importantly, been completely enwrapped by well-developed anorthite crystals in the glaze, indicating that the signals recorded in previous publications are probably not from cobalt pigments themselves but from outside thickset anorthite shell. The further spectromicroscopic analyses confirm this presumption when the accurate spectra of cobalt aluminate pigment and surrounding anorthite were obtained separately with precise optical positioning. Accordingly, we reassess and clarify the previous Raman studies dedicated to cobalt blue pigment in ancient ceramics, e.g. cobalt blue in celadon glaze, and in turn demonstrate the superiority and necessity of coupling spectroscopic analysis with corresponding structure observation, especially in the characterization of pigments from complicated physico-chemical environment like antiquities. Thus, this study promotes a better understanding of Raman spectroscopy study of cobalt blue pigments in art and archaeology field. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Barton, Sinead J.; Kerr, Laura T.; Domijan, Katarina; Hennelly, Bryan M.
2016-04-01
Raman micro-spectroscopy is an optoelectronic technique that can be used to evaluate the chemical composition of biological samples and has been shown to be a powerful diagnostic tool for the investigation of various cancer related diseases including bladder, breast, and cervical cancer. Raman scattering is an inherently weak process with approximately 1 in 107 photons undergoing scattering and for this reason, noise from the recording system can have a significant impact on the quality of the signal, and its suitability for diagnostic classification. The main sources of noise in the recorded signal are shot noise, CCD dark current, and CCD readout noise. Shot noise results from the low signal photon count while dark current results from thermally generated electrons in the semiconductor pixels. Both of these noise sources are time dependent; readout noise is time independent but is inherent in each individual recording and results in the fundamental limit of measurement, arising from the internal electronics of the camera. In this paper, each of the aforementioned noise sources are analysed in isolation, and used to experimentally validate a mathematical model. This model is then used to simulate spectra that might be acquired under various experimental conditions including the use of different cameras, different source wavelength, and power etc. Simulated noisy datasets of T24 and RT112 cell line spectra are generated based on true cell Raman spectrum irradiance values (recorded using very long exposure times) and the addition of simulated noise. These datasets are then input to multivariate classification using Principal Components Analysis and Linear Discriminant Analysis. This method enables an investigation into the effect of noise on the sensitivity and specificity of Raman based classification under various experimental conditions and using different equipment.
Raman analysis of cobalt blue pigment in blue and white porcelain: A reassessment
NASA Astrophysics Data System (ADS)
Jiang, Xiaochenyang; Ma, Yanying; Chen, Yue; Li, Yuanqiu; Ma, Qinglin; Zhang, Zhaoxia; Wang, Changsui; Yang, Yimin
2018-02-01
Cobalt blue is a famous pigment in human history. In the past decade it is widely reported that the cobalt aluminate has been detected in ancient ceramics as blue colorant in glaze, yet the acquired Raman spectra are incredibly different from that of synthesised references, necessitating a reassessment of such contradictory scenario with more accurate analytic strategies. In this study, micro-Raman spectroscopy (MRS) and scanning electron microscopy (SEM) in association with energy dispersive spectrometry (EDS) were performed on under-glaze cobalt pigments from one submerged blue and white porcelain shard dated from Wanli reign (1573-1620 CE) of Ming dynasty (1365-1644 CE) excavated at Nan'ao I shipwreck off the southern coast of China. The micro-structural inspection reveals that the pigment particles have characteristics of small account, tiny size, heterogeneously distribution, and more importantly, been completely enwrapped by well-developed anorthite crystals in the glaze, indicating that the signals recorded in previous publications are probably not from cobalt pigments themselves but from outside thickset anorthite shell. The further spectromicroscopic analyses confirm this presumption when the accurate spectra of cobalt aluminate pigment and surrounding anorthite were obtained separately with precise optical positioning. Accordingly, we reassess and clarify the previous Raman studies dedicated to cobalt blue pigment in ancient ceramics, e.g. cobalt blue in celadon glaze, and in turn demonstrate the superiority and necessity of coupling spectroscopic analysis with corresponding structure observation, especially in the characterization of pigments from complicated physico-chemical environment like antiquities. Thus, this study promotes a better understanding of Raman spectroscopy study of cobalt blue pigments in art and archaeology field.
Electron microscopy and forensic practice
NASA Astrophysics Data System (ADS)
Kotrlý, Marek; Turková, Ivana
2013-05-01
Electron microanalysis in forensic practice ranks among basic applications used in investigation of traces (latents, stains, etc.) from crime scenes. Applying electron microscope allows for rapid screening and receiving initial information for a wide range of traces. SEM with EDS/WDS makes it possible to observe topography surface and morphology samples and examination of chemical components. Physical laboratory of the Institute of Criminalistics Prague use SEM especially for examination of inorganic samples, rarely for biology and other material. Recently, possibilities of electron microscopy have been extended considerably using dual systems with focused ion beam. These systems are applied mainly in study of inner micro and nanoparticles , thin layers (intersecting lines in graphical forensic examinations, analysis of layers of functional glass, etc.), study of alloys microdefects, creating 3D particles and aggregates models, etc. Automated mineralogical analyses are a great asset to analysis of mineral phases, particularly soils, similarly it holds for cathode luminescence, predominantly colour one and precise quantitative measurement of their spectral characteristics. Among latest innovations that are becoming to appear also at ordinary laboratories are TOF - SIMS systems and micro Raman spectroscopy with a resolution comparable to EDS/WDS analysis (capable of achieving similar level as through EDS/WDS analysis).
Wavelet data processing of micro-Raman spectra of biological samples
NASA Astrophysics Data System (ADS)
Camerlingo, C.; Zenone, F.; Gaeta, G. M.; Riccio, R.; Lepore, M.
2006-02-01
A wavelet multi-component decomposition algorithm is proposed for processing data from micro-Raman spectroscopy (μ-RS) of biological tissue. The μ-RS has been recently recognized as a promising tool for the biopsy test and in vivo diagnosis of degenerative human tissue pathologies, due to the high chemical and structural information contents of this spectroscopic technique. However, measurements of biological tissues are usually hampered by typically low-level signals and by the presence of noise and background components caused by light diffusion or fluorescence processes. In order to overcome these problems, a numerical method based on discrete wavelet transform is used for the analysis of data from μ-RS measurements performed in vitro on animal (pig and chicken) tissue samples and, in a preliminary form, on human skin and oral tissue biopsy from normal subjects. Visible light μ-RS was performed using a He-Ne laser and a monochromator with a liquid nitrogen cooled charge coupled device equipped with a grating of 1800 grooves mm-1. The validity of the proposed data procedure has been tested on the well-characterized Raman spectra of reference acetylsalicylic acid samples.
L, Frère; I, Paul-Pont; J, Moreau; P, Soudant; C, Lambert; A, Huvet; E, Rinnert
2016-12-15
Every step of microplastic analysis (collection, extraction and characterization) is time-consuming, representing an obstacle to the implementation of large scale monitoring. This study proposes a semi-automated Raman micro-spectroscopy method coupled to static image analysis that allows the screening of a large quantity of microplastic in a time-effective way with minimal machine operator intervention. The method was validated using 103 particles collected at the sea surface spiked with 7 standard plastics: morphological and chemical characterization of particles was performed in <3h. The method was then applied to a larger environmental sample (n=962 particles). The identification rate was 75% and significantly decreased as a function of particle size. Microplastics represented 71% of the identified particles and significant size differences were observed: polystyrene was mainly found in the 2-5mm range (59%), polyethylene in the 1-2mm range (40%) and polypropylene in the 0.335-1mm range (42%). Copyright © 2016 Elsevier Ltd. All rights reserved.
Raman-in-SEM, a multimodal and multiscale analytical tool: performance for materials and expertise.
Wille, Guillaume; Bourrat, Xavier; Maubec, Nicolas; Lahfid, Abdeltif
2014-12-01
The availability of Raman spectroscopy in a powerful analytical scanning electron microscope (SEM) allows morphological, elemental, chemical, physical and electronic analysis without moving the sample between instruments. This paper documents the metrological performance of the SEMSCA commercial Raman interface operated in a low vacuum SEM. It provides multiscale and multimodal analyses as Raman/EDS, Raman/cathodoluminescence or Raman/STEM (STEM: scanning transmission electron microscopy) as well as Raman spectroscopy on nanomaterials. Since Raman spectroscopy in a SEM can be influenced by several SEM-related phenomena, this paper firstly presents a comparison of this new tool with a conventional micro-Raman spectrometer. Then, some possible artefacts are documented, which are due to the impact of electron beam-induced contamination or cathodoluminescence contribution to the Raman spectra, especially with geological samples. These effects are easily overcome by changing or adapting the Raman spectrometer and the SEM settings and methodology. The deletion of the adverse effect of cathodoluminescence is solved by using a SEM beam shutter during Raman acquisition. In contrast, this interface provides the ability to record the cathodoluminescence (CL) spectrum of a phase. In a second part, this study highlights the interest and efficiency of the coupling in characterizing micrometric phases at the same point. This multimodal approach is illustrated with various issues encountered in geosciences. Copyright © 2014 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cui, Y; Roy, U N; Bai, L
Ytterbium doped strontium fluoroapatite Yb{sup 3+}:Sr{sub 5}(PO{sub 4}){sub 3}F (Yb: S-FAP) crystals have been used in High Average Power Laser systems as gain medium. Growth induced defects associated with the crystal often affect their performance. In order to improve the crystal quality and its optical applications, it is imperative to understand the nature of these defects. In this study, we utilize Micro-Raman spectroscopy to characterize two common growth-induced defects: bubble core and cloudiness. We find the bubble core consist of voids and microcrystals of Yb: S-FAP. These microcrystals have very different orientation from that of the pure crystal outside themore » bubble core. In contrast to a previous report, neither Sr{sub 3}(PO{sub 4}){sub 2} nor Yb{sub 2}O{sub 3} are observed in the bubble core regions. On the other hand, the cloudy regions are made up of the host materials blended with a structural deformation along with impurities which include CaCO{sub 3}, YbPO{sub 4}, SrHPO{sub 4} and Sr{sub 2}P{sub 2}O{sub 7}. The impurities are randomly distributed in the cloudy regions. This analysis is necessary for understanding and eliminating these growth defects in Yb:S-FAP crystals.« less
Tomasini, Eugenia P; Marte, Fernando; Careaga, Valeria P; Landa, Carlos Rúa; Siracusano, Gabriela; Maier, Marta S
2016-12-13
The image of Our Lady of Copacabana, a gilded polychrome sculpture carved in maguey wood in 1583, is one of the most important devotions in the Americas. In former research, we have identified the use of gypsum, Armenian bole, cerussite and atacamite in its polychromy. In this study, a red sample taken from the Virgin's tunic and a blue sample extracted from the cloak have been analysed with the aim to identify both pigments and offer insights into the painting technique. Analysis by micro-Raman spectroscopy complemented with scanning electron microscopy-energy dispersive spectroscopy and high-performance liquid chromatography allowed the identification of carmine lake in the red sample. Analysis by micro-Raman spectroscopy of the surface of the blue sample and its cross section showed the presence of smalt-the blue-glass pigment-over a cerussite layer, bathed by a very thin ultramarine layer-from a probable native origin-following a pictorial tradition that would last even until the eighteenth century. This is the first time that lapis lazuli has been scientifically identified in a Spanish American colonial painted layer.This article is part of the themed issue 'Raman spectroscopy in art and archaeology'. © 2016 The Author(s).
Tomasini, Eugenia P.; Marte, Fernando; Careaga, Valeria P.; Landa, Carlos Rúa; Siracusano, Gabriela
2016-01-01
The image of Our Lady of Copacabana, a gilded polychrome sculpture carved in maguey wood in 1583, is one of the most important devotions in the Americas. In former research, we have identified the use of gypsum, Armenian bole, cerussite and atacamite in its polychromy. In this study, a red sample taken from the Virgin's tunic and a blue sample extracted from the cloak have been analysed with the aim to identify both pigments and offer insights into the painting technique. Analysis by micro-Raman spectroscopy complemented with scanning electron microscopy–energy dispersive spectroscopy and high-performance liquid chromatography allowed the identification of carmine lake in the red sample. Analysis by micro-Raman spectroscopy of the surface of the blue sample and its cross section showed the presence of smalt—the blue-glass pigment—over a cerussite layer, bathed by a very thin ultramarine layer—from a probable native origin—following a pictorial tradition that would last even until the eighteenth century. This is the first time that lapis lazuli has been scientifically identified in a Spanish American colonial painted layer. This article is part of the themed issue ‘Raman spectroscopy in art and archaeology’. PMID:27799431
NASA Astrophysics Data System (ADS)
Tomasini, Eugenia P.; Marte, Fernando; Careaga, Valeria P.; Landa, Carlos Rúa; Siracusano, Gabriela; Maier, Marta S.
2016-12-01
The image of Our Lady of Copacabana, a gilded polychrome sculpture carved in maguey wood in 1583, is one of the most important devotions in the Americas. In former research, we have identified the use of gypsum, Armenian bole, cerussite and atacamite in its polychromy. In this study, a red sample taken from the Virgin's tunic and a blue sample extracted from the cloak have been analysed with the aim to identify both pigments and offer insights into the painting technique. Analysis by micro-Raman spectroscopy complemented with scanning electron microscopy-energy dispersive spectroscopy and high-performance liquid chromatography allowed the identification of carmine lake in the red sample. Analysis by micro-Raman spectroscopy of the surface of the blue sample and its cross section showed the presence of smalt-the blue-glass pigment-over a cerussite layer, bathed by a very thin ultramarine layer-from a probable native origin-following a pictorial tradition that would last even until the eighteenth century. This is the first time that lapis lazuli has been scientifically identified in a Spanish American colonial painted layer. This article is part of the themed issue "Raman spectroscopy in art and archaeology".
Carbon Isotopic Compositions in Carbon Dioxide Measured By Micro-Laser Raman Spectroscopy
NASA Astrophysics Data System (ADS)
Li, J.-J.; Li, R.-X.; Dong, H.; Wang, Zh.-H.; Zhao, B.-S.; Wang, N.; Cheng, J.-H.
2017-05-01
We have prepared a series of 12CO2/13CO2 binary mixtures as standard samples at room temperature. Using microlaser Raman spectroscopy, it was found that the relationship between the 12CO2 mole fractions and the peak area ratios of 12CO2/13CO2 in the Raman spectra of CO2 binary mixtures showed a polynomial correlation. The establishment of the experimental working curve paves the way for estimating the mole fractions of each individual fluid inclusion and determining 13C/12C and δ13C u sing micro-Raman spectroscopy. The Raman spectra of 12CO2 and 13CO2 showed a characteristic peak at 1348 cm-1 with an argon laser at 785 nm, which is perhaps due to the formation of dimers.
Samudrala, Gopi K.; Moore, Samuel L.; Velisavljevic, Nenad; ...
2016-09-29
By combining mask-less lithography and chemical vapor deposition (CVD) techniques, a novel two-stage diamond anvil has been fabricated. A nanocrystalline diamond (NCD) micro-anvil 30 μm in diameter was grown at the center of a [100]-oriented, diamond anvil by utilizing microwave plasma CVD method. The NCD micro-anvil has a diamond grain size of 115 nm and micro-focused Raman and X-ray Photoelectron spectroscopy analysis indicate sp3-bonded diamond content of 72%. Lastly, these CVD grown NCD micro-anvils were tested in an opposed anvil configuration and the transition metals osmium and tungsten were compressed to high pressures of 264 GPa in a diamond anvilmore » cell.« less
NASA Astrophysics Data System (ADS)
De Biasio, M.; Kraft, M.; Schultz, M.; Goller, B.; Sternig, D.; Esteve, R.; Roesner, M.
2017-05-01
Silicon carbide (SiC) is a wide band-gap semi-conductor material that is used increasingly for high voltage power devices, since it has a higher breakdown field strength and better thermal conductivity than silicon. However, in particular its hardness makes wafer processing difficult and many standard semi-conductor processes have to be specially adapted. We measure the effects of (i) mechanical processing (i.e. grinding of the backside) and (ii) chemical and thermal processing (i.e. doping and annealing), using confocal microscopy to measure the surface roughness of ground wafers and micro-Raman spectroscopy to measure the stresses induced in the wafers by grinding. 4H-SiC wafers with different dopings were studied before and after annealing, using depth-resolved micro-Raman spectroscopy to observe how doping and annealing affect: i.) the damage and stresses induced on the crystalline structure of the samples and ii.) the concentration of free electrical carriers. Our results show that mechanical, chemical and thermal processing techniques have effects on this semiconductor material that can be observed and characterized using confocal microscopy and high resolution micro Raman spectroscopy.
NASA Astrophysics Data System (ADS)
Mohajerani, M. S.; Khachadorian, S.; Schimpke, T.; Nenstiel, C.; Hartmann, J.; Ledig, J.; Avramescu, A.; Strassburg, M.; Hoffmann, A.; Waag, A.
2016-02-01
Three-dimensional III-nitride micro-structures are being developed as a promising candidate for the future opto-electrical devices. In this study, we demonstrate a quick and straight-forward method to locally evaluate free-carrier concentrations and a crystalline quality in individual GaN:Si micro-rods. By employing micro-Raman mapping and analyzing lower frequency branch of A1(LO)- and E1(LO)-phonon-plasmon-coupled modes (LPP-), the free carrier concentrations are determined in axial and planar configurations, respectively. Due to a gradual doping profile along the micro-rods, a highly spatially resolved mapping on the sidewall is exploited to reconstruct free carrier concentration profile along the GaN:Si micro-rods. Despite remarkably high free carrier concentrations above 1 × 1020 cm-3, the micro-rods reveal an excellent crystalline quality, without a doping-induced stress.
Powerful Raman Lidar systems for atmospheric analysis and high-energy physics experiments
NASA Astrophysics Data System (ADS)
Avdikos, George
2015-03-01
In this paper the author presents modern commercial Raman Lidar systems which can be applied to high-energy physics experiments. Raymetrics is a world-leader in laser remote (lidar) sensing applications. Products series include lidar systems for various applications like atmospheric analysis, meteorology, and recently more operational applications including volcanic ash detection systems, visual rangers for application to airports etc.
NASA Astrophysics Data System (ADS)
Bullen, P. S.; Huang, H.-C.; Yang, H.; Dadap, J. I.; Kymissis, I.; Osgood, R. M.
2016-07-01
The domain structure of poled deeply thinned lithium niobate is investigated as a function of sample thickness. Free-standing samples of thickness from 25 to 500 μm are prepared by a multiple-cycle polish and annealing procedure and then periodically poled. Using these samples and employing micro-Raman scattering and scanning electron, atomic force, and optical microscopy together, the domain broadening and poling voltage are found to vary in a regular and significant manner. The poled domains show a reduction in width spreading of 38% as the sample thickness is reduced from 500 to 25 μm. Micro-Raman probe measurements verify the quality and the uniformity of the poled domains and provide insight into their thickness-dependent poling contrast.
Holakooei, Parviz; Karimy, Amir-Hossein; Hasanpour, Ata; Oudbashi, Omid
2016-12-05
This paper reports the results of studies performed on a painted stucco fragment excavated at the Ghaleh Guri in Ramavand, western Iran, and dated back to the late Sasanian period (224-651AD). Analytical studies including micro-Raman spectroscopy (μ-Raman), micro-X-ray spectrometry (μ-XRF) and optical microscopy showed that red lead and vermilion were used as main pigments on this fragment. Moreover, carbon black was diagnosed to thinly cover some parts of the red lead. Peculiarly, wulfenite (PbMoO4) associated with vanadinite (Pb5(VO4)3Cl) was identified to compose a yellow stain sporadically dispersed on the other pigments. Copyright © 2016 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baraliya, J. D.
2016-05-23
Manganese substituted Cobalt ferrites of composition with nominal formula Co{sub (1−x)}Mn{sub (x)}Fe{sub 2}O{sub 4} (x = 0.0, 0.2, 0.4, 0.6, 0.8, 1.0) prepared by the Flash Combustion Method(FCM). The single phase spinel formation of nano ferrites was confirmed by X-ray diffraction techniques and micro - Raman spectroscopy. The particle size calculated from the Scherrer formula varied within 13 to 17 nm. Lattice parameter, nano particle size, and cation distribution were quantified as a function of the Mn-content in the range x = 0.0 to 1.0. Micro-Raman spectroscopic studies yielded convincing evidence for a transformation of the structure.
NASA Astrophysics Data System (ADS)
Mohajerani, M. S.; Khachadorian, S.; Nenstiel, C.; Schimpke, T.; Avramescu, A.; Strassburg, M.; Hoffmann, A.; Waag, A.
2016-03-01
The controlled growth of highly n-doped GaN micro rods is one of the major challenges in the fabrication of recently developed three-dimensional (3D) core-shell light emitting diodes (LEDs). In such structures with a large active area, higher electrical conductivity is needed to achieve higher current density. In this contribution, we introduce high quality heavily-doped GaN:Si micro-rods which are key elements of the newly developed 3D core-shell LEDs. These structures were grown by metal-organic vapor phase epitaxy (MOVPE) using selective area growth (SAG). We employed spatially resolved micro-Raman and micro-photoluminescence (PL) in order to directly determine a free-carrier concentration profile in individual GaN micro-rods. By Raman spectroscopy, we analyze the low-frequency branch of the longitudinal optical (LO)-phonon-plasmon coupled modes and estimate free carrier concentrations from ≍ 2.4 × 1019 cm-3 up to ≍ 1.5 × 1020 cm-3. Furthermore, free carrier concentrations are determined by estimating Fermi energy level from the near band edge emission measured by low-temperature PL. The results from both methods reveal a good consistency.
Facile synthesis of one dimensional ZnO nanostructures for DSSC applications
NASA Astrophysics Data System (ADS)
Marimuthu, T.; Anandhan, N.
2016-05-01
Development of zinc oxide (ZnO) nanostructure based third generation dye sensitized solar cell is interesting compared to conventional silicon solar cells. ZnO nanostructured thin films were electrochemically deposited onto fluorine doped tin oxide (FTO) glass substrate. The effect of ethylene-diamine-tetra-acetic acid (EDTA) on structural, morphological and optical properties is investigated using X-ray diffraction (XRD) meter, field emission scanning electron microscope (FE-SEM) and micro Raman spectroscopy. XRD patterns reveal that the prepared nanostructures are hexagonal wutrzite structures with (101) plane orientation, the nanostructure prepared using EDTA exhibits better crystallinity. FE-SEM images illustrate that the morphological changes are observed from nanorod structure to cauliflower like structure as EDTA is added. Micro Raman spectra predict that cauliflower like structure possesses a higher crystalline nature with less atomic defects compared to nanorod structures. Dye sensitized solar cell (DSSC) is constructed for the optimized cauliflower structure, and open circuit voltage, short circuit density, fill factor and efficiency are estimated from the J-V curve.
Raman spectroscopy, "big data", and local heterogeneity of solid state synthesized lithium titanate
NASA Astrophysics Data System (ADS)
Pelegov, Dmitry V.; Slautin, Boris N.; Gorshkov, Vadim S.; Zelenovskiy, Pavel S.; Kiselev, Evgeny A.; Kholkin, Andrei L.; Shur, Vladimir Ya.
2017-04-01
Existence of defects is an inherent property of real materials. Due to an explicit correlation between defects concentration and conductivity, it is important to understand the level and origins of the structural heterogeneity for any particulate electrode material. Poor conductive lithium titanate Li4Ti5O12 (LTO), widely used in batteries for grids and electric buses, needs it like no one else. In this work, structural heterogeneity of compacted lithium titanate is measured locally in 100 different points by conventional micro-Raman technique, characterized in terms of variation of Raman spectra parameters and interpreted using our version of "big data" analysis. This very simple approach with automated measurement and treatment has allowed us to demonstrate inherent heterogeneity of solid-state synthesized LTO and attribute it to the existence of lithium and oxygen vacancies. The proposed approach can be used as a fast, convenient, and cost-effective defects-probing tool for a wide range of materials with defects-sensitive properties. In case of LTO, such an approach can be used to increase its charge/discharge rates by synthesis of materials with controlled nonstoichiometry. New approaches to solid state synthesis of LTO, suitable for high-power applications, will help to significantly reduce the costs of batteries for heavy-duty electric vehicles and smart-grids.
NASA Astrophysics Data System (ADS)
Xie, Changan; Li, Yong-qing
2003-03-01
We report on the study of single biological cells with a confocal micro-Raman spectroscopy system that uses optical trapping and shifted excitation Raman difference technique. A tunable diode laser was used to capture a living cell in solution, confine it in the confocal excitation volume, and then excite the Raman scattering. The optical trapping allows us to lift the cell well off the cover plate so that the fluorescence interference from the plate can be effectively reduced. In order to further remove the interference of the fluorescence and stray light from the trapped cell, we employed a shifted excitation Raman difference technique with slightly tuned laser frequencies. With this system, high-quality Raman spectra were obtained from single optically trapped biological cells including E. coli bacteria, yeast cells, and red blood cells. A significant difference between control and heat-treated E. coli B cells was observed due to the denaturation of biomolecules.
Synthesis of sub-micro-flakes CrSe2 on glass and (110) Si substrates by solvothermal method
NASA Astrophysics Data System (ADS)
Tang, Qingkai; Liu, Changyou; Zhang, Binbin; Jie, Wanqi
2018-06-01
Layered structure MX2 (M = transition metal, X = S, Se and Te) chalcogenides have rich physic properties and potential applications. While it is still a challenge to prepare the chalcogenides by solvothermal method. In this work, we reported a new solution method to prepare CrSe2 sub-micro-flakes on different substrates. The surface morphologies, structures and compositions of the precursor CrSe2(en)1/2 and CrSe2 were investigated by SEM, XRD, thermogravimetric, IR and Raman spectra. The CrSe2 flakes with the sizes of 5-15 μm were obtained on both glass and (110) Si crystalline substrates. The formation mechanism of CrSe2 sub-micro-flakes is suggested.
Raman spectroscopic analysis of cytotoxic effect of cisplatin-treated leukemic cells
NASA Astrophysics Data System (ADS)
Lin, Juqiang; Li, Yongzeng; Feng, Shangyuan; Chen, Rong; Chen, Guannan; Chen, Qisong; Pan, Jianji; Lin, Shaojun; Yu, Yun
2009-08-01
An antitumor drug cisplatin was employed to treat the leukemic cells and induce apoptosis of the cancer cells. Confocal Raman micro-spectroscopy has been applied to investigate the effectiveness of the treatment using near-infrared laser (785nm) excitation, scanning range from 500 to 2000 cm-1. The Raman spectra of leukemic cell treated with cisplatin for 4, 6, 8, 12 and 14 h were measured separately. The major difference of the apoptotic cells from the cancer cells are the reduction in intensities of vibration bands generated by cellular lipids, proteins and nucleic acids. In particular, large intensity reduction in nucleic vibrations at 782, 1092, 1320, 1340, and 1578 cm-1 was observed upon apoptosis of the leukemic cells. Up to 45% reduction in the magnitude of the 782 cm-1 peak in Raman spectra of the apoptotic cells was observed, which suggests the breakdown of phosphodiester bonds and DNA bases. We showed that the principal components analysis (PCA), a multivariate statistical tool, can be used to distinguish single apoptotic cells and leukemic cells based on their Raman spectra. Our results indicate that the Raman spectroscopy with PCA is a novel, nondestructive mean for studying the cisplatin -treated leukemic cells, which could also provide useful data for clinical dosage optimization for cisplatin.
Raman analysis of ancient pigments on a tile from the Citadel of Algiers.
Kock, L D; De Waal, D
2008-12-15
A micro-Raman spectroscopy study of a multi-coloured (yellow, blue, white, redish-brown and brown-black) tile shard from the Citadel of Algiers was undertaken. XRD and EDX were used as complementary techniques. The study shows that the heterogeneous three-shade yellow pigment on the tile is composed largely of the ancient ternary (Pb-Sn-Sb) pyrochlore oxide with a dominant Pb-O vibration at 127 cm(-1) consistent with the Pb2SnSbO6.5 structure as verified by XRD. The literature assignment of this band at 132 cm(-1) probably comes from a mixture of pigments. The redish-brown and the brown-black pigments are found to be Naples yellow (Pb2Sb2O7) and lead(II) stannate (Pb2SnO4), respectively, while cobalt blue (CoAl2O4) gives the blue colour and cassiterite (SnO2) is the origin of the white colour. The bulk of the tile body is composed mainly of hematite (alpha-Fe2O3), maghemite (gamma-Fe2O3), magnetite (Fe3O4) and Quartz (alpha-SiO2) with traces of calcite (CaCO3) and amorphous carbon. Micro-Raman spectroscopy proved to be very useful in the characterization of pigments as well as the tile body. These results further establish Raman spectroscopy as a technique of choice for the analysis of pigments on archaeological artifacts. The results obtained here could be used in the restoration and preservation programme of the Citadel itself which stands today as a symbol of pre-colonial Algerian heritage.
Raman analysis of ancient pigments on a tile from the Citadel of Algiers
NASA Astrophysics Data System (ADS)
Kock, L. D.; De Waal, D.
2008-12-01
A micro-Raman spectroscopy study of a multi-coloured (yellow, blue, white, redish-brown and brown-black) tile shard from the Citadel of Algiers was undertaken. XRD and EDX were used as complementary techniques. The study shows that the heterogeneous three-shade yellow pigment on the tile is composed largely of the ancient ternary (Pb-Sn-Sb) pyrochlore oxide with a dominant Pb-O vibration at 127 cm -1 consistent with the Pb 2SnSbO 6.5 structure as verified by XRD. The literature assignment of this band at 132 cm -1 probably comes from a mixture of pigments. The redish-brown and the brown-black pigments are found to be Naples yellow (Pb 2Sb 2O 7) and lead(II) stannate (Pb 2SnO 4), respectively, while cobalt blue (CoAl 2O 4) gives the blue colour and cassiterite (SnO 2) is the origin of the white colour. The bulk of the tile body is composed mainly of hematite (α-Fe 2O 3), maghemite (γ-Fe 2O 3), magnetite (Fe 3O 4) and Quartz (α-SiO 2) with traces of calcite (CaCO 3) and amorphous carbon. Micro-Raman spectroscopy proved to be very useful in the characterization of pigments as well as the tile body. These results further establish Raman spectroscopy as a technique of choice for the analysis of pigments on archaeological artifacts. The results obtained here could be used in the restoration and preservation programme of the Citadel itself which stands today as a symbol of pre-colonial Algerian heritage.
Emerging non-invasive Raman methods in process control and forensic applications.
Macleod, Neil A; Matousek, Pavel
2008-10-01
This article reviews emerging Raman techniques (Spatially Offset and Transmission Raman Spectroscopy) for non-invasive, sub-surface probing in process control and forensic applications. New capabilities offered by these methods are discussed and several application examples are given including the non-invasive detection of counterfeit drugs through blister packs and opaque plastic bottles and the rapid quantitative analysis of the bulk content of pharmaceutical tablets and capsules without sub-sampling.
A comparative study of heterostructured CuO/CuWO4 nanowires and thin films
NASA Astrophysics Data System (ADS)
Polyakov, Boris; Kuzmin, Alexei; Vlassov, Sergei; Butanovs, Edgars; Zideluns, Janis; Butikova, Jelena; Kalendarev, Robert; Zubkins, Martins
2017-12-01
A comparative study of heterostructured CuO/CuWO4 core/shell nanowires and double-layer thin films was performed through X-ray diffraction, confocal micro-Raman spectroscopy and electron (SEM and TEM) microscopies. The heterostructures were produced using a two-step process, starting from a deposition of amorphous WO3 layer on top of CuO nanowires and thin films by reactive DC magnetron sputtering and followed by annealing at 650 °C in air. The second step induced a solid-state reaction between CuO and WO3 oxides through a thermal diffusion process, revealed by SEM-EDX analysis. Morphology evolution of core/shell nanowires and double-layer thin films upon heating was studied by electron (SEM and TEM) microscopies. A formation of CuWO4 phase was confirmed by X-ray diffraction and confocal micro-Raman spectroscopy.
NASA Astrophysics Data System (ADS)
Chen, Qiong
Containing only earth abundant and environmental friendly elements, quaternary compounds Cu2ZnSnS4 (CZTS) and Cu2ZnSnSe 4 (CZTSe) are considered as promising absorber materials for thin film solar cells. The best record efficiency for this type of thin film solar cell is now 12.6%. As a promising photovoltaic (PV) material, the electrical and optical properties of CZTS(Se) have not been well studied. In this work, an effort has been made to understand the optoelectronic and structural properties, in particular the spatial variations, of CZTS(Se) materials and devices by correlating multiple spatially resolved characterization techniques with sub-micron resolution. Micro-Raman (micro-Raman) spectroscopy was used to analyze the chemistry compositions in CZTS(Se) film; Micro-Photoluminescence (micro-PL) was used to determine the band gap and possible defects. Micro-Laser-Beam-Induced-Current (micro-LBIC) was used to examine the photo-response of CZTS(Se) solar cell in different illumination conditions. Micro-reflectance was used to estimate the reflectance loss. And Micro-I-V measurement was used to compare important electrical parameters from CZTS(Se) solar cells with different device structure or absorber compositions. Scanning electron microscopy and atomic force microscopy were used to characterize the surface morphology. Successfully integrating and correlating these techniques was first demonstrated during the course of this work in our laboratory, and this level of integration and correlation has been rare in the field of PV research. This effort is significant not only for this particular project and also for a wide range of research topics. Applying this approach, in conjunction with high-temperature and high-excitation-power optical spectroscopy, we have been able to reveal the microscopic scale variations among samples and devices that appeared to be very similar from macroscopic material and device characterizations, and thus serve as a very powerful tool to understand the underlying microscopic material structures and predict the potential of improvement in device performance. First, by using an array of correlated aforementioned techniques, microscale inhomogeneity of the CdS layer thickness was found in CZTSe solar cells. Thicker CdS regions are found to cause more light-reflection loss thus yielding lower external quantum efficiencies (EQEs) than the general area. However, these regions show much less efficiency degradation at high illumination density, leading to an inversion of LBIC contrast between the CdS rich regions and general area. By improving the CdS layer uniformity, CZTSe device performance can be significantly boosted. And this finding also points out the possibility of operating thin-film photovoltaic device based on similar materials under substantially higher illumination density for concentrated photovoltaic and photo-detection. Second, Micro-Raman reveals multiple secondary phases such as ZnSe and SnSe within the CZTSe films, which are harmful for solar cell operation. In high-laser-power Raman study, CZTSe shows structural change and decomposition, which indicates poor thermal conductivity of the polycrystalline film. Different behaviors of CZTSe films prepared by different methods are observed in high-laser-power and high-temperature Raman studies, both of which offer effective approaches to examine microscopic structural variation of nominally similar CZTSe films. Because of the achieved high spatial resolution, applying micro-Raman and micro-LBIC, we are able to examine the depth variation of the thin absorber film (in the order of 1 microm) in terms of chemical composition, photo-response, and deposition method dependence. In the third part, micro-I-V curves offer direct measurements of electrical parameters reflecting the effects of the device structure, absorber thickness and elemental ratio on the CZTSe cell performance. NaF precursor, low copper and high zinc content are demonstrated necessary for high performance CZTSe devices. However, one cell with higher copper and lower zinc content experiences slower EQE droop at high power density and part of the film shows better thermal conductivity, which suggests that the CdS/CZTSe heterojunction band alignment depends on the elemental ratio of the CZTSe film and CZTSe may have a potential in concentrated PV application if the elemental ratio can be optimized.
Effect of Co doping on structural and mechanical properties of CeO2
NASA Astrophysics Data System (ADS)
Tiwari, Saurabh; Balasubramanian, Nivedha; Biring, Sajal; Sen, Somaditya
2018-05-01
Sol-gel synthesized nanocrystalline Co doped CeO2 powders [(Ce1-xCoxO2; x=0, 0.03)] were made into cylindrical discs by uniaxial pressing and sintered at 1500°C for 24h to measure mechanical properties. The pure phase formation of undoped and Co doped samples were confirmed by X-ray diffraction and Raman analysis. The scanning electron microscopy (SEM) was used for observing the microstructure of sintered samples to investigate density, porosity, and grain size. The grains size observed for 1500°C sintered samples 5-8 µm. Vickers indentation method used for investigating the micro-hardness. For undoped CeO2 micro-hardness was found 6.2 GPa which decreased with Co doping. It was found that samples follow indentation size effect (ISE) and follow elastic than plastic deformation. Enhanced ductile nature with Co doping in CeO2 made it more promising material for optoelectronic device applications.
Stress transfer of a Kevlar 49 fiber pullout test studied by micro-Raman spectroscopy.
Lei, Zhenkun; Wang, Quan; Qiu, Wei
2013-06-01
The interfacial stress transfer behavior of a Kevlar 49 aramid fiber-epoxy matrix was studied with fiber pullout tests, the fibers of which were stretched by a homemade microloading device. Raman spectra on the embedded fiber were recorded by micro-Raman spectroscopy, under different strain levels. Then, the fiber axial stress was obtained by the relationship between the stress and Raman shift of the aramid fiber. Experimental results revealed that the fiber axial stress increased significantly with the load. The shear stress concentration occurred at the fiber entry to the epoxy resin. Thus, interfacial friction stages exist in the debonded fiber segment, and the interfacial friction shear stress is constant within one stage. The experimental results are consistent with the theoretical model predictions.
Five-year Effects of Chlorhexidine on the In Vitro Durability of Resin/Dentin Interfaces.
Loguercio, Alessandro D; Hass, Viviane; Gutierrez, Mario Felipe; Luque-Martinez, Issis Virginia; Szezs, Anna; Stanislawczuk, Rodrigo; Bandeca, Matheus Coelho; Reis, Alessandra
2016-01-01
To evaluate the effect of an acid containing 2% chlorhexidine (Ac/CHX) or a 2% CHX aqueous solution (Aq/CHX) on the immediate and 5-year bonding properties of resin/dentin interfaces produced by two adhesives. The presence of CHX in these interfaces was also evaluated under micro-Raman spectroscopy. Forty-two molars were ground to expose a flat dentin surface. In the control group, the surfaces were etched with conventional phosphoric acid, and Prime&Bond NT (PB) and Adper Single Bond 2 (SB) were applied. In Ac/CHX, an acid containing 2% CHX was applied after adhesive application. In the Aq/CHX group, an aqueous solution of 2% CHX was applied for 60 s after etching. After placing the restoration, specimens were prepared and tested using the microtensile bond strength test (μTBS, 0.5 mm/min) immediately or after 5 years. For nanoleakage (NL), specimens at each period were immersed in silver nitrate solution and examined by EDX-SEM. In addition, specimens at each period underwent examination for CHX using micro-Raman spectroscopy. Data were submitted to appropriate statistical analysis (a=0.05). After 5 years, NL was more pronounced in the control than in the Ac/CHX or Aq/CHX (p<0.001). Significant reductions in the μTBS were observed for all groups; however, they were more pronounced for the control (p<0.001). CHX was still present in the hybrid layers Ac/CHX or Aq/CHX groups after 5 years. The use of a 2% chlorhexidine-containing acid or the application of an aqueous CHX primer may increase the long-term stability of resin/dentin interfaces.
Campbell, Jos L; SoRelle, Elliott D; Ilovich, Ohad; Liba, Orly; James, Michelle L; Qiu, Zhen; Perez, Valerie; Chan, Carmel T; de la Zerda, Adam; Zavaleta, Cristina
2017-08-01
Despite extensive research and development, new nano-based diagnostic contrast agents have faced major barriers in gaining regulatory approval due to their potential systemic toxicity and prolonged retention in vital organs. Here we use five independent biodistribution techniques to demonstrate that oral ingestion of one such agent, gold-silica Raman nanoparticles, results in complete clearance with no systemic toxicity in living mice. The oral delivery mimics topical administration to the oral cavity and gastrointestinal (GI) tract as an alternative to intravenous injection. Biodistribution and clearance profiles of orally (OR) vs. intravenously (IV) administered Raman nanoparticles were assayed over the course of 48 h. Mice given either an IV or oral dose of Raman nanoparticles radiolabeled with approximately 100 μCi (3.7MBq) of 64 Cu were imaged with dynamic microPET immediately post nanoparticle administration. Static microPET images were also acquired at 2 h, 5 h, 24 h and 48 h. Mice were sacrificed post imaging and various analyses were performed on the excised organs to determine nanoparticle localization. The results from microPET imaging, gamma counting, Raman imaging, ICP-MS, and hyperspectral imaging of tissue sections all correlated to reveal no evidence of systemic distribution of Raman nanoparticles after oral administration and complete clearance from the GI tract within 24 h. Paired with the unique signals and multiplexing potential of Raman nanoparticles, this approach holds great promise for realizing targeted imaging of tumors and dysplastic tissues within the oral cavity and GI-tract. Moreover, these results suggest a viable path for the first translation of high-sensitivity Raman contrast imaging into clinical practice. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Itasaka, Hiroki; Mimura, Ken-ichi; Nishi, Masayuki; Kato, Kazumi
2018-05-01
We investigated the influence of heat treatment on the crystallographic structure and ferroelectric phase transition behavior of barium titanate (BaTiO3, BT) nanocubes assembled into highly ordered monolayers, using tip-enhanced Raman spectroscopy (TERS), temperature-dependent micro-Raman spectroscopy, and scanning transmission electron microscopy (STEM). TER spectra from individual BT nanocubes with the size of about 20 nm were obtained with a side-illumination optical setup, and revealed that heat treatment enhances their tetragonality. The result of temperature-dependent micro-Raman spectroscopy showed that the ferroelectric phase transition behavior of the monolayers becomes similar to that of bulk BT through heat treatment in spite of their thickness. STEM observation for the cross-section of the heated BT nanocube monolayer showed that amorphous layers exist at the interface between BT nanocubes in face-to-face contact. These results indicate that the tetragonal crystal structure of BT nanocubes is stabilized by heat treatment and the formation of the interfacial amorphous layer during heat treatment may be a key to this phenomenon.
Camorani, Paolo; Chiavaro, Emma; Cristofolini, Luigi; Paciulli, Maria; Zaupa, Maria; Visconti, Attilio; Fogliano, Vincenzo; Pellegrini, Nicoletta
2015-08-30
Raman spectroscopy, in its confocal micro-Raman variation, has been recently proposed as a spatially resolved method to identify carotenoids in various food matrices, being faster, non-destructive, and avoiding sample extraction, but no data are present in the literature concerning its application to the evaluation of carotenoid pattern changes after thermal treatment of carrots. The effect of three cooking methods (i.e. boiling, steaming and microwaving) was evaluated on frozen carrot, comparing changes on carotenoid profiles measured by means of Raman spectroscopy with their high-performance liquid chromatographic determination and colour. A more pronounced detrimental effect on carotenoids was detected in steamed carrots, in accordance with colour data. Conversely, boiling and, to a lesser extent, microwaving caused an increase in carotenoid concentration. Cooking procedures affected the Raman spectral features of carotenoids, causing a shift of vibration frequencies towards a higher energy, increase in the spectral baseline and peak intensities as well as a broadening of their width, probably in relation to the thermal degradation of longer carotenoids (i.e. the all-trans form) and the isomerization process. In particular, steamed samples showed a significantly higher increase of centre frequency, in accordance with a more pronounced isomerization and changes in colour parameters. This work showed that the evolution of Raman spectral parameters could provide information on carotenoid bioaccessibility for carrots cooked using various methods. This paves the way for a future use of this technique to monitor and optimize cooking processes aimed at maximizing carotenoid bioaccessibility and bioavailability. © 2014 Society of Chemical Industry.
Detection of edge component of threading dislocations in GaN by Raman spectroscopy
NASA Astrophysics Data System (ADS)
Kokubo, Nobuhiko; Tsunooka, Yosuke; Fujie, Fumihiro; Ohara, Junji; Hara, Kazukuni; Onda, Shoichi; Yamada, Hisashi; Shimizu, Mitsuaki; Harada, Shunta; Tagawa, Miho; Ujihara, Toru
2018-06-01
We succeeded in measuring the density and direction of the edge component of threading dislocations (TDs) in c-plane (0001) GaN by micro-Raman spectroscopy mapping. In the micro-Raman spectroscopy mapping of the E2 H peak shift between 567.85 and 567.75 cm‑1, six different contrast images are observed toward directions of < 1\\bar{1}00> . By comparing X-ray topography and etch pit images, the E2 H peak shift is observed where the edge component of TDs exists. In contrast, the E2 H peak is not observed where the screw component of TDs exists.
Feng, Shaolong; Eucker, Tyson P.; Holly, Mayumi K.; Konkel, Michael E.
2014-01-01
We present the results of a study using high-throughput whole-transcriptome sequencing (RNA-seq) and vibrational spectroscopy to characterize and fingerprint pathogenic-bacterium injury under conditions of unfavorable stress. Two garlic-derived organosulfur compounds were found to be highly effective antimicrobial compounds against Cronobacter sakazakii, a leading pathogen associated with invasive infection of infants and causing meningitis, necrotizing entercolitis, and bacteremia. RNA-seq shows changes in gene expression patterns and transcriptomic response, while confocal micro-Raman spectroscopy characterizes macromolecular changes in the bacterial cell resulting from this chemical stress. RNA-seq analyses showed that the bacterial response to ajoene differed from the response to diallyl sulfide. Specifically, ajoene caused downregulation of motility-related genes, while diallyl sulfide treatment caused an increased expression of cell wall synthesis genes. Confocal micro-Raman spectroscopy revealed that the two compounds appear to have the same phase I antimicrobial mechanism of binding to thiol-containing proteins/enzymes in bacterial cells generating a disulfide stretching band but different phase II antimicrobial mechanisms, showing alterations in the secondary structures of proteins in two different ways. Diallyl sulfide primarily altered the α-helix and β-sheet, as reflected in changes in amide I, while ajoene altered the structures containing phenylalanine and tyrosine. Bayesian probability analysis validated the ability of principal component analysis to differentiate treated and control C. sakazakii cells. Scanning electron microscopy confirmed cell injury, showing significant morphological variations in cells following treatments by these two compounds. Findings from this study aid in the development of effective intervention strategies to reduce the risk of C. sakazakii contamination in the food production environment and on food contact surfaces, reducing the risks to susceptible consumers. PMID:24271174
Pumping capacity and reliability of cryogenic micro-pump for micro-satellite applications
NASA Astrophysics Data System (ADS)
Zhang, Xin; Zhao, Yi; Li, Biao; Ludlow, Daryl
2004-10-01
In micro-satellites, delicate instruments are compacted into a limited space. This raises concerns of active cooling and remote cooling. Silicon based micro-pump arrays are employed thanks to manufacturing simplicity, a small cryogen charge, etc, and keep the instruments within a narrow cryogenic temperature range. The pumping capacity and reliability of the micro-pump are critical in terms of heat balance calculation and lifetime evaluation. The pumping capacity is associated with the diaphragm deflection while the reliability is associated with stress and fatigue. Both of them heavily depend on the silicon diaphragm, one of the key components. This paper examines the pumping capacity and reliability of the micro-pump under cryogenic temperature for micro-satellite applications. In this work, differential pressure was used for the actuation of a single-crystal silicon diaphragm. Diaphragm deflection and stress distribution were achieved using interferometry and micro-Raman spectroscopy, respectively. As a result, smaller pumping capacity was derived under cryogenic temperature, compared to that under room temperature, indicating a stiffer material. From stress mapping, the edge centers were believed to be the most vulnerable to fracture, which was further validated by analyzing the fracture diaphragm. Moreover, a fatigue testing was conducted for 1.8 million cycles with no damage found, verifying silicon as a viable material for long time operation in a cryogenic environment.
Increasing the speed of tumour diagnosis during surgery with selective scanning Raman microscopy
NASA Astrophysics Data System (ADS)
Kong, Kenny; Rowlands, Christopher J.; Varma, Sandeep; Perkins, William; Leach, Iain H.; Koloydenko, Alexey A.; Pitiot, Alain; Williams, Hywel C.; Notingher, Ioan
2014-09-01
One of the main challenges in cancer surgery is ensuring that all tumour cells are removed during surgery, while sparing as much healthy tissue as possible. Histopathology, the gold-standard technique for cancer diagnosis, is often impractical for intra-operative use because of the time-consuming tissue preparation procedures (sectioning and staining). Raman micro-spectroscopy is a powerful technique that can discriminate between tumours and healthy tissues with high accuracy, based entirely on intrinsic chemical differences. However, raster-scanning Raman micro-spectroscopy is a slow imaging technique that typically requires data acquisition times as long as several days for typical tissue samples obtained during surgery (1 × 1 cm2) - in particular when high signal-to-noise ratio spectra are required to ensure accurate diagnosis. In this paper we present two techniques based on selective sampling Raman micro-spectroscopy that can overcome these limitations. In selective sampling, information regarding the spatial features of the tissue, either measured by an alternative optical technique or estimated in real-time from the Raman spectra, can be used to drastically reduce the number of Raman spectra required for diagnosis. These sampling strategies allowed diagnosis of basal cell carcinoma in skin tissue samples excised during Mohs micrographic surgery faster than frozen section histopathology, and two orders of magnitude faster than previous techniques based on raster-scanning Raman microscopy. Further development of these techniques may help during cancer surgery by providing a fast and objective way for surgeons to ensure the complete removal of tumour cells while sparing as much healthy tissue as possible.
Taurino, R; Cannio, M; Mafredini, T; Pozzi, P
2014-01-01
In this study, X-ray fluorescence (XRF) spectroscopy was used, in combination with micro-Raman spectroscopy, for a fast determination of bromine concentration and then of brominated flame retardants (BFRs) compounds in waste electrical and electronic equipments. Different samples from different recycling industries were characterized to evaluate the sorting performances of treatment companies. This investigation must be considered of prime research interest since the impact of BFRs on the environment and their potential risk on human health is an actual concern. Indeed, the new European Restriction of Hazardous Substances Directive (RoHS 2011/65/EU) demands that plastics with BFRs concentration above 0.1%, being potential health hazards, are identified and eliminated from the recycling process. Our results show the capability and the potential of Raman spectroscopy, together with XRF analysis, as effective tools for the rapid detection of BFRs in plastic materials. In particular, the use of these two techniques in combination can be considered as a promising method suitable for quality control applications in the recycling industry.
Liu, Yan-de; Jin, Tan-tan
2015-09-01
The quality and safety of agricultural products and people health are inseparable. Using the conventional chemical methods which have so many defects, such as sample pretreatment, complicated operation process and destroying the samples. Raman spectroscopy as a powerful tool of analysing and testing molecular structure, can implement samples quickly without damage, qualitative and quantitative detection analysis. With the continuous improvement and the scope of the application of Raman spectroscopy technology gradually widen, Raman spectroscopy technique plays an important role in agricultural products quality and safety determination, and has wide application prospects. There have been a lot of related research reports based on Raman spectroscopy detection on agricultural product quality safety at present. For the understanding of the principle of detection and the current development situation of Raman spectroscopy, as well as tracking the latest research progress both at home and abroad, the basic principles and the development of Raman spectroscopy as well as the detection device were introduced briefly. The latest research progress of quality and safety determination in fruits and vegetables, livestock and grain by Raman spectroscopy technique were reviewed deeply. Its technical problems for agricultural products quality and safety determination were pointed out. In addition, the text also briefly introduces some information of Raman spectrometer and the application for patent of the portable Raman spectrometer, prospects the future research and application.
Micro-Raman spectroscopy study of the effect of Mid-Ultraviolet radiation on erythrocyte membrane.
Li, N; Li, S X; Guo, Z Y; Zhuang, Z F; Li, R; Xiong, K; Chen, S J; Liu, S H
2012-07-02
Mid-Ultraviolet (UVB) has a significant influence on human health. In this study, human erythrocytes were exposed to UVB to investigate the effects of UVB radiation on erythrocytes membrane. And Micro-Raman spectroscopy was employed to detect the damage. Principal component analysis (PCA) was used to classify the control erythrocytes and the irradiated erythrocytes. Results showed that the erythrocytes membrane was damaged by Mid-Ultraviolet (UVB) radiation. The intensity of the Raman peaks at 1126 cm(-1) and 1082 cm(-1) were used to calculate the Longitudinal Order-Parameters in Chains (S(trans)) which can present the liquidity and ionic permeability of erythrocyte membrane. After UVB radiation for 30 min, both the liquidity and ionic permeability decreased. At the same time, the intensity of the peaks at 1302 cm(-1) (α-helix), 1254 cm(-1) (random coil), 1452 cm(-1) and 1430 cm(-1) (CH(2)/CH(3) stretch) have also changed which indicated the membrane protein also been damaged by UVB. In the whole process of radiation, the more UVB radiation dose the more damage on the erythrocyte membrane. Copyright © 2012 Elsevier B.V. All rights reserved.
In Situ Planetary Mineralogy Using Simultaneous Time Resolved Fluorescence and Raman Spectroscopy
NASA Technical Reports Server (NTRS)
Blacksberg, J.; Rossman , G.R.
2011-01-01
Micro-Raman spectroscopy is one of the primary methods of mineralogical analysis in the laboratory, and more recently in the field. Because of its versatility and ability to interrogate rocks in their natural form it is one of the front runners for the next generation of in situ instruments designed to explore adverse set of solar system bodies (e.g. Mars, Venus, the Moon, and other primitive bodies such as asteroids and the Martian moons Phobos and Deimos), as well as for pre-selection of rock and soil samples for potential cache and return missions.
NASA Astrophysics Data System (ADS)
Rinaudo, C.; Croce, A.; Allegrina, M.; Baris, I. Y.; Dogan, A.; Powers, A.; Rivera, Z.; Bertino, P.; Yang, H.; Gaudino, G.; Carbone, M.
2013-05-01
Exposure to mineral fibers such asbestos and erionite is widely associated with the development of lung cancer and pleural malignant mesothelioma (MM). Pedigree and mineralogical studies indicated that genetics may influence mineral fiber carcinogenesis. Although dimensions strongly impact on the fiber carcinogenic potential, also the chemical composition and the fiber is relevant. By using micro-Raman spectroscopy we show here persistence and identification of different mineral phases, directly on histopathological specimens of mice and humans. Fibers of crocidolite asbestos and erionite of different geographic areas (Oregon, US and Cappadocia, Turkey) were injected in mice intra peritoneum. MM developed in 10/15 asbestos-treated mice after 5 months, and in 8-10/15 erionite-treated mice after 14 months. The persistence of the injected fibers was investigated in pancreas, liver, spleen and in the peritoneal tissue. The chemical identification of the different phases occurred in the peritoneal cavity or at the organ borders, while only rarely fibers were localized in the parenchyma. Raman patterns allow easily to recognize crocidolite and erionite fibers. Microscopic analysis revealed that crocidolite fibers were frequently coated by ferruginous material ("asbestos bodies"), whereas erionite fibers were always free from coatings. We also analyzed by micro-Raman spectroscopy lung tissues, both from MM patients of the Cappadocia, where a MM epidemic developed because of environmental exposure to erionite, and from Italian MM patients with occupational exposure to asbestos. Our findings demonstrate that micro-Raman spectroscopy is technique able to identify mineral phases directly on histopathology specimens, as routine tissue sections prepared for diagnostic purpose. REFERENCES A.U. Dogan, M. Dogan. Environ. Geochem. Health 2008, 30(4), 355. M. Carbone, S. Emri, A.U. Dogan, I. Steele, M. Tuncer, HI. Pass, et al. Nat. Rev. Cancer. 2007, 7 (2),147. M. Carbone, Y.I. Baris, P. Bertino, B. Brass, S. Comertpay, A.U. Dogan et al. Proc. Nat. Acad. Sci U S A 2011;108 (33), 13618. A.U. Dogan, Y.I.Baris, M. Dogan, S. Emri, I. Steele, A.G. Elmishad et al. Cancer Res. 2006,66 (10), 5063. M. Dogan. Scanning. 2012, 34 (1), 37. C. Rinaudo, M. Allegrina, E. Fornero, M. Musa, A. Croce, D. Bellis. J. Raman Spectrosc. 2010, 41 (1), 27. C. Rinaudo, A. Croce, M. Musa, E. Fornero, M. Allegrina, P. Trivero, et al. Appl. Spectrosc. 2010, 64 (6), 571. M. Musa, A. Croce, M. Allegrina, C. Rinaudo, E. Belluso, D. Bellis, et al. Vib. Spectrosc. 2012, 61, 66.
Multifarious applications of atomic force microscopy in forensic science investigations.
Pandey, Gaurav; Tharmavaram, Maithri; Rawtani, Deepak; Kumar, Sumit; Agrawal, Y
2017-04-01
Forensic science is a wide field comprising of several subspecialties and uses methods derived from natural sciences for finding criminals and other evidence valid in a legal court. A relatively new area; Nano-forensics brings a new era of investigation in forensic science in which instantaneous results can be produced that determine various agents such as explosive gasses, biological agents and residues in different crime scenes and terrorist activity investigations. This can be achieved by applying Nanotechnology and its associated characterization techniques in forensic sciences. Several characterization techniques exist in Nanotechnology and nano-analysis is one such technique that is used in forensic science which includes Electron microscopes (EM) like Transmission (TEM) and Scanning (SEM), Raman microscopy (Micro -Raman) and Scanning Probe Microscopes (SPMs) like Atomic Force Microscope (AFM). Atomic force microscopy enables surface characterization of different materials by examining their morphology and mechanical properties. Materials that are immeasurable such as hair, body fluids, textile fibers, documents, polymers, pressure sensitive adhesives (PSAs), etc. are often encountered during forensic investigations. This review article will mainly focus on the use of AFM in the examination of different evidence such as blood stains, forged documents, human hair samples, ammunitions, explosives, and other such applications in the field of Forensic Science. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Burlet, C.; Vanbrabant, Y.; Decree, S.
2014-06-01
This study defines Raman reference spectra for heterogenite, asbolane and lithiophorite. Those three phases are hardly differenciable by XRD. Raman spectroscopy allows comparison of their natural chemical variability with their spectroscopic signatures.
Goodall, Rosemary A; Hall, Jay; Sharer, Robert J; Traxler, Loa; Rintoul, Llew; Fredericks, Peter M
2008-01-01
Fourier transform infrared (FT-IR) attenuated total reflection (ATR) imaging has been successfully used to identify individual mineral components of ancient Maya paint. The high spatial resolution of a micro FT-IR-ATR system in combination with a focal plane array detector has allowed individual particles in the paint to be resolved and identified from their spectra. This system has been used in combination with micro-Raman spectroscopy to characterize the paint, which was found to be a mixture of hematite and silicate particles with minor amounts of calcite, carbon, and magnetite particles in a sub-micrometer hematite and calcite matrix. The underlying stucco was also investigated and found to be a combination of calcite with fine carbon particles, making a dark sub-ground for the paint.
Electromagnetic Field Enhancement on Axially Heterostructured NWs: The Role of the Heterojunctions
NASA Astrophysics Data System (ADS)
Pura, J. L.; Souto, J.; Periwal, P.; Baron, T.; Jiménez, J.
2018-05-01
Semiconductor nanowires are the building blocks of future nanoelectronic devices. The study of the interaction between nanowires and visible light reveals resonances that promise light absorption/scattering engineering for photonic applications. We carried out experimental measurements through the micro-Raman spectroscopy of different group IV nanowires, both homogeneous Si nanowires and axially heterostructured SiGe/Si nanowires. These experimental measurements show an enhancement of the Raman signal in the vicinity of the heterojunction of SiGe/Si nanowires. The results are analysed in terms of the electromagnetic modelling of the light/nanowire interaction using finite element methods. The presence of axial heterostructures is shown to produce electromagnetic resonances, and the results are understood as a consequence of a finite change in the relative permittivity of the material at the SiGe/Si heterojunction. This effect opens a path to controlling interactions between light and matter at the nanoscale with direct applications in photonic nanodevices.
NASA Astrophysics Data System (ADS)
Dong, Jun; Wang, Xiaolei; Zhang, Mingming; Wang, Xiaojie; He, Hongsen
2018-04-01
Structured optical vortices with 4 phase singularities have been generated in a laser diode pumped continuous-wave Yb:Y3Al5O12/YVO4 (Yb:YAG/YVO4) Raman microchip laser. The broadband comb-like first order Stokes laser emitting spectrum including 30 longitudinal modes covers from 1072.49 nm to 1080.13 nm with a bandwidth of 7.64 nm, which is generated with the Raman shift 259 cm-1 of the c-cut YVO4 crystal converted from the fundamental laser around 1.05 μm. Pump power dependent optical vortex beams are attributed to overlap of the Stokes laser field with the fundamental laser field caused by dynamically changing the coupling losses of the fundamental laser field. The maximum output power is 1.16 W, and the optical-to-optical efficiency is 18.4%. This work provides a method for generating structured optical vortices with an optical frequency comb in solid-state Raman microchip lasers, which have potential applications in quantum computations, micro-machining, and information processing.
Enhanced Uranium Ore Concentrate Analysis by Handheld Raman Sensor: FY15 Status Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bryan, Samuel A.; Johnson, Timothy J.; Orton, Christopher R.
2015-11-11
High-purity uranium ore concentrates (UOC) represent a potential proliferation concern. A cost-effective, “point and shoot” in-field analysis capability to identify ore types, phases of materials present, and impurities, as well as estimate the overall purity would be prudent. Handheld, Raman-based sensor systems are capable of identifying chemical properties of liquid and solid materials. While handheld Raman systems have been extensively applied to many other applications, they have not been broadly studied for application to UOC, nor have they been optimized for this class of chemical compounds. PNNL was tasked in Fiscal Year 2015 by the Office of International Safeguards (NA-241)more » to explore the use of Raman for UOC analysis and characterization. This report summarizes the activities in FY15 related to this project. The following tasks were included: creation of an expanded library of Raman spectra of a UOC sample set, creation of optimal chemometric analysis methods to classify UOC samples by their type and level of impurities, and exploration of the various Raman wavelengths to identify the ideal instrument settings for UOC sample interrogation.« less
NASA Astrophysics Data System (ADS)
Potcoava, Mariana C.; Futia, Gregory L.; Aughenbaugh, Jessica; Schlaepfer, Isabel; Gibson, Emily A.
2014-03-01
Increasing interest in the role of lipids in cancer cell proliferation or resistance to drug therapies has motivated the need to develop better tools for cellular lipid analysis. Quantification of lipids in cells is typically done by destructive chromatography protocols that do not provide spatial information on lipid distribution and prevent dynamic live cell studies. Methods that allow the analysis of lipid content in live cells is therefore of great importance for research. Using Raman micro-spectroscopy we investigated whether the female hormone medroxyprogesterone acetate (MPA) and the synthetic androgen R1881 affect the lipid expression in breast (T47D) and prostate (LNCaP) cancer cells. Differences were noted in the spectral regions at 830-1800 cm-1 and 2800-3000 cm-1 when comparing different drug treatments. Significant changes were noticed for saturated (1063 - 1125 cm-1, 1295 cm-1 and 1439 cm-1), unsaturated (1262 cm-1 and 1656 cm-1, and 1720 - 1748 cm-1) chemical bonds, suggesting that the composition of the lipid droplets was changed by the hormone treatments. Also, significant differences were observed in the high frequency regions of lipids and proteins at 2851 cm-1 and around 2890 cm-1. Principal component analysis with Linear Discriminant Analysis (PCA-LDA) of the Raman spectra was able to differentiate between cancer cells that were treated with MPA, R1881 or vehicle (P < 0.05). Future work includes analysis to determine exact lipid composition and concentrations as well as development of clinical techniques to characterize differences in patient tumor lipid profiles to determine response to drug treatment and prognosis.
Bi, Xiaohong; Sterling, Julie A.; Merkel, Alyssa R.; Perrien, Daniel S.; Nyman, Jeffry; Mahadevan-Jansen, Anita
2013-01-01
Prostate cancer is the most common primary tumor and the second leading cause of cancer-related deaths in men in the United States. Prostate cancer bone metastases are characterized by abnormal bone remodeling processes and result in a variety of skeletal morbidities. Prevention of skeletal complications is a crucial element in prostate cancer management. This study investigated prostate cancer-induced alterations in the molecular composition and morphological structure of metastasis-bearing bones in a mouse model of prostate cancer using Raman spectroscopy and micro-computed tomography (microCT). LNCaP C4-2B prostate cancer cells were injected into the right tibiae of 5-week old male SCID mice. Upon sacrifice at 8 weeks post tumor inoculation, two out of the ten tumor-bearing tibiae showed only osteoblastic lesions in the radiographs, 4 osteolytic lesions only and 4 mixed with osteoblastic and osteolytic lesions.. Carbonate substitution was significantly increased while there was a marked reduction in the level of collagen mineralization, mineral crystallinity, and carbonate:matrix ratio in the cortex of the intact tumor-bearing tibiae compared to contralateral controls. MicroCT analysis revealed a significant reduction in bone volume/total volume, trabecular number and trabecular thickness, as well as significant increase in bone surface/volume ratio in tibiae with osteolytic lesions, suggesting active bone remodeling and bone loss. None of the changes in bone compositional properties were correlated with lesion area from radiographs or the changes in bone architecture from microCT. This study indicates that LNCaP C4-2B prostate cancer metastases alter bone tissue composition independent of changes in architecture, and altered bone quality may be an important contributor to fracture risk in these patients. Raman spectroscopy may provide a new avenue of investigation into interactions between tumor and bone microenvironment. PMID:23867219
New Applications of Portable Raman Spectroscopy in Agri-Bio-Photonics
NASA Astrophysics Data System (ADS)
Voronine, Dmitri; Scully, Rob; Sanders, Virgil
2014-03-01
Modern optical techniques based on Raman spectroscopy are being used to monitor and analyze the health of cattle, crops and their natural environment. These optical tools are now available to perform fast, noninvasive analysis of live animals and plants in situ. We will report new applications of a portable handheld Raman spectroscopy to identification and taxonomy of plants. In addition, detection of organic food residues will be demonstrated. Advantages and limitations of current portable instruments will be discussed with suggestions for improved performance by applying enhanced Raman spectroscopic schemes.
Koralay, Tamer; Kadioglu, Yusuf Kagan
2008-03-01
Medium to large volume ignimbrites usually show vertical changes in terms of color, mineral components, texture and geochemistry. Determination of vertical changes in single extensive ignimbrite flow unit is difficult and requires careful studies. Color changes in ignimbrite flow units are very important for earth scientists. This may cause to identify the same ignimbrite series with different definition. Incesu ignimbrite has a wide distribution in the Central Anatolian Volcanic Province (CAVP). It is classified into three levels as lower, middle and upper according to color and welding degree. There is a sharp contact between the lower and middle level. The lower level is dark brown to black in color and the middle level has pinkish red to red color. The present paper focuses on the investigation of color changes between the ignimbrite levels by using micro-XRF and confocal Raman spectrometry. Micro-XRF and Raman spectrometry studies were performed on the polished thin sections of the lower and middle levels with different compositions. These differences were because of the compositional changes of K and slightly Fe elements distribution within the matrix. The dark brown to black color of the lower level was related to the high concentration of the K and Fe relatively to the middle level. Confocal Raman spectrometry investigations exhibited the matrix of the lower level mainly composed of anorthoclase, supporting the results of the micro-XRF.
Pressure-tuning micro-Raman spectra of artists' pigments: α- and β-copper phthalocyanine polymorphs.
Beaulieu-Houle, Guillaume; Gilson, Denis F R; Butler, Ian S
2014-01-03
The two polymorphs of copper phthalocyanine, α- and β-CuPc, have been examined by micro-Raman spectroscopy at pressures approaching 5.0 GPa. The metastable α-polymorph does not exhibit any structural changes, while the more thermodynamically stable β-polymorph does exhibit a reversible phase transition at 2.0 GPa. The pressure dependences (dν/dP) for a selected number of vibrational modes are reported. Two regions of the Raman spectra, 800-900 cm(-1) and 1100-1200 cm(-1), are sensitive to pressure such that they can be used as indicators of the polymorphic form. Copyright © 2013 Elsevier B.V. All rights reserved.
Fujihara, J; Fujita, Y; Yamamoto, T; Nishimoto, N; Kimura-Kataoka, K; Kurata, S; Takinami, Y; Yasuda, T; Takeshita, H
2017-03-01
Raman spectroscopy is commonly used in chemistry to identify molecular structure. This technique is a nondestructive analysis and needs no sample preparation. Recently, Raman spectroscopy has been shown to be effective as a multipurpose analytical method for forensic applications. In the present study, blood identification and discrimination between human and nonhuman blood were performed by a portable Raman spectrometer, which can be used at a crime scene. To identify the blood and to discriminate between human and nonhuman blood, Raman spectra of bloodstains from 11 species (human, rat, mouse, cow, horse, sheep, pig, rabbit, cat, dog, and chicken) were taken using a portable Raman spectrometer. Raman peaks for blood (742, 1001, 1123, 1247, 1341, 1368, 1446, 1576, and 1619 cm -1 ) could be observed by the portable Raman spectrometer in all 11 species, and the human bloodstain could be distinguished from the nonhuman ones by using a principal component analysis. This analysis can be performed on a bloodstain sample of at least 3 months old. The portable Raman spectrometer can be used at a crime scene, and this analysis is useful for forensic examination.
Design of micro-second pulsed laser mode for ophthalmological CW self-raman laser
NASA Astrophysics Data System (ADS)
Mota, Alessandro D.; Rossi, Giuliano; Ortega, Tiago A.; Costal, Glauco Z.; Fontes, Yuri C.; Yasuoka, Fatima M. M.; Stefani, Mario A.; de Castro N., Jarbas C.; Paiva, Maria S. V.
2011-02-01
This work presents the mechanisms adopted for the design of micro-second pulsed laser mode for a CW Self-Raman laser cavity in 586nm and 4W output power. The new technique for retina disease treatment discharges laser pulses on the retina tissue, in laser sequences of 200 μs pulse duration at each 2ms. This operation mode requires the laser to discharge fast electric pulses, making the system control velocity of the electronic system cavity vital. The control procedures to keep the laser output power stable and the laser head behavior in micro-second pulse mode are presented.
NASA Astrophysics Data System (ADS)
Zeng, Huidan; Wang, Ling; Ye, Feng; Yang, Bin; Chen, Jianding; Chen, Guorong; Sun, Luyi
2016-11-01
Chemical strengthening of aluminosilicate glasses through K+-Na+ ion exchange has attracted tremendous attentions because of the accelerating demand for high strength and damage resistance glasses. However, a paramount challenge still exists to fabricate glasses with a higher strength and greater depth of ion-exchange layer. Herein, aluminosilicate glasses with different contents of P2O5 were prepared and the influence of P2O5 on the increased compressive stress and depth of ion-exchange layer was investigated by micro-Raman technique. It was noticed that the hardness, compressive stress, as well as the depth of ion-exchange layer substantially increased with an increasing concentration of P2O5 varied from 1 to 7 mol%. The obtained micro-Raman spectra confirmed the formation of relatively depolymerized silicate anions that accelerated the ion exchange. Phosphorus containing aluminosilicate glasses with a lower polymerization degree exhibited a higher strength and deeper depth of ion-exchange layer, which suggests that the phosphorus containing aluminosilicate glasses have promising applications in flat panel displays, windshields, and wafer sealing substrates.
NASA Astrophysics Data System (ADS)
Almeida, R. M.; Andreeta, M. R. B.; Hernandes, A. C.; Dias, A.; Moreira, R. L.
2014-03-01
Infrared-reflectivity spectroscopy and micro-Raman scattering were used to determine the optical phonon features of orthorhombic calcium tantalite (CaTa2O6) single crystal fibres. The fibres, obtained by the Laser-Heated Pedestal Growth method, grew into an ordered cubic structure \\left( Pm\\bar{3} \\right). Long-time annealing was used to induce a polymorphic transformation to an aeschynite orthorhombic structure (Pnma space group). The phase transformation led to the appearance of structural domains and micro-cracks, responsible for diffuse scattering and depolarization of the scattered light in the visible range, but not in the infrared region. Thus, polarized infrared spectroscopy could be performed within oriented single domains, with an appropriate microscope, allowing us to determine all relevant polar phonons of the orthorhombic CaTa2O6. The obtained phononic dielectric response, {{\\epsilon }_{r}} = 22.4 and
Ali, Esam M A; Edwards, Howell G M; Scowen, Ian J
2011-10-01
Trace amounts of street samples of cocaine hydrochloride and N-methyl-3,4-methylenedioxy-amphetamine (MDMA) on natural and synthetic textiles were successfully detected in situ using confocal Raman microscopy. The presence of some excipient bands in the spectra of the drugs did not prevent the unambiguous identification of the drugs. Raman spectra of the drugs were readily obtained without significant interference from the fibre substrates. Interfering bands arising from the fibre natural or synthetic polymer structure and/or dye molecules did not overlap with the characteristic Raman bands of the drugs. If needed, interfering bands could be successfully removed by spectral subtraction. Also, Raman spectra could be acquired from drug particles trapped between the fibres of highly fluorescent textile specimens. The total acquisition time of the spectra of the drug particles was 90 s accomplished non-destructively and without detachment from their substrates. Sample preparation was not required and spectra of the drugs could be obtained non-invasively preserving the integrity of the evidential material for further analysis. Copyright © 2010 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Ali, Esam M. A.; Edwards, Howell G. M.; Scowen, Ian J.
2011-10-01
Trace amounts of street samples of cocaine hydrochloride and N-methyl-3,4-methylenedioxy-amphetamine (MDMA) on natural and synthetic textiles were successfully detected in situ using confocal Raman microscopy. The presence of some excipient bands in the spectra of the drugs did not prevent the unambiguous identification of the drugs. Raman spectra of the drugs were readily obtained without significant interference from the fibre substrates. Interfering bands arising from the fibre natural or synthetic polymer structure and/or dye molecules did not overlap with the characteristic Raman bands of the drugs. If needed, interfering bands could be successfully removed by spectral subtraction. Also, Raman spectra could be acquired from drug particles trapped between the fibres of highly fluorescent textile specimens. The total acquisition time of the spectra of the drug particles was 90 s accomplished non-destructively and without detachment from their substrates. Sample preparation was not required and spectra of the drugs could be obtained non-invasively preserving the integrity of the evidential material for further analysis.
Forensic and homeland security applications of modern portable Raman spectroscopy.
Izake, Emad L
2010-10-10
Modern detection and identification of chemical and biological hazards within the forensic and homeland security contexts may well require conducting the analysis in field while adapting a non-contact approach to the hazard. Technological achievements on both surface and resonance enhancement Raman scattering re-developed Raman spectroscopy to become the most adaptable spectroscopy technique for stand-off and non-contact analysis of hazards. On the other hand, spatially offset Raman spectroscopy proved to be very valuable for non-invasive chemical analysis of hazards concealed within non-transparent containers and packaging. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
Handheld confocal Raman microspectrometer for in-vivo skin cancer measurement
NASA Astrophysics Data System (ADS)
Lieber, Chad A.; Ellis, Darrel L.; Billheimer, D. D.; Mahadevan-Jansen, Anita
2004-07-01
Several studies have demonstrated Raman spectroscopy to be capable of tissue diagnosis with accuracy rivaling that of histopathologic analysis. This technique obtains biochemical-specific information noninvasively, and can eliminate the pain, time, and cost associated with biopsy and pathological analysis. Furthermore, when used in a confocal arrangement, Raman spectra can be obtained from localized regions of the tissue. Skin cancers are an ideal candidate for this emerging technology, due to their obvious accessibility and presentation at specific depths. However, most commercially available confocal Raman microspectrometers are large, rigid systems ill-suited for clinical application. We developed a bench-top confocal Raman microspectrometer using a portable external-cavity diode laser excitation source. This system was used to study several skin lesions in vitro. Results show the depth-resolved Raman spectra can diagnose in vitro skin lesions with 96% sensitivity, 88% specificity, and 86% pathological classification accuracy. Based on the success of this study, a portable Raman system with a handheld confocal microscope was developed for clinical application. Preliminary in vivo data show several distinct spectral differences between skin pathologies. Diagnostic algorithms are planned for this continuing study to assess the capability of Raman spectroscopy for clinical skin cancer diagnosis.
Characterization of the Ground Paprika Samples Using Raman Spectroscopy
NASA Astrophysics Data System (ADS)
Gucsik, A.; Veres, M.; Himics, L.; Rigó, I.
2017-11-01
Micro-Raman spectroscopy as a powerful technique can be used in food industry, especially in the ground pepper or paprika characterization in order to deter-mine the paprika sample’s origin as well as their quality.
West, Matthew J; Went, Michael J
2008-01-15
The application of powders to fingerprints has long been established as an effective and reliable method for developing latent fingerprints. The powders adhere to the ridge pattern of the fingerprint only, thus allowing the image to be visualised. Fingerprints developed in situ at a crime scene routinely undergo lifting with specialist tapes to facilitate subsequent laboratory analysis. As with all recovered evidence these samples would be stored in evidence bags to allow secure transit from the scene to the laboratory and also to preserve the chain of evidence. In this paper, the application of Raman spectroscopy for the analysis of exogenous material in latent fingerprints is reported for contaminated fingerprints that had been treated with powders and also subsequently lifted with adhesive tapes. A selection of over the counter (OTC) analgesics were used as samples for the analysis and contaminated fingerprints were deposited on clean glass slides. The application of aluminium or iron based powders to contaminated fingerprints did not interfere with the Raman spectra obtained for the contaminants. In most cases background fluorescence attributed to the sebaceous content of the latent fingerprint was reduced by the application of the powder thus reducing spectral interference. Contaminated fingerprints developed with powders and then lifted with lifting tapes were also examined. The combination of these two techniques did not interfere with the successful analysis of exogenous contaminants by Raman spectroscopy. The lifting process was repeated using hinge lifters. As the hinge lifters exhibited strong Raman bands the spectroscopic analysis was more complex and an increase in the number of exposures to the detector allowed for improved clarification. Raman spectra of developed and lifted fingerprints recorded through evidence bags were obtained and it was found that the detection process was not compromised in any way. Although the application of powders did not interfere with the detection process the time taken to locate the contaminant was increased due to the physical presence of more material within the fingerprint. The presence of interfering Raman bands from lifting tapes is another potential complication. This, however, could be removed by spectral subtraction or by the choice of lifting tapes that have only weak Raman bands.
Detection and Monitoring of Neurotransmitters - a Spectroscopic Analysis
NASA Astrophysics Data System (ADS)
Manciu, Felicia; Lee, Kendall; Durrer, William; Bennet, Kevin
2012-10-01
In this work we demonstrate the capability of confocal Raman mapping spectroscopy for simultaneously and locally detecting important compounds in neuroscience such as dopamine, serotonin, and adenosine. The Raman results show shifting of the characteristic vibrations of the compounds, observations consistent with previous spectroscopic studies. Although some vibrations are common in these neurotransmitters, Raman mapping was achieved by detecting non-overlapping characteristic spectral signatures of the compounds, as follows: for dopamine the vibration attributed to C-O stretching, for serotonin the indole ring stretching vibration, and for adenosine the adenine ring vibrations. Without damage, dyeing, or preferential sample preparation, confocal Raman mapping provided positive detection of each neurotransmitter, allowing association of the high-resolution spectra with specific micro-scale image regions. Such information is particularly important for complex, heterogeneous samples, where modification of the chemical or physical composition can influence the neurotransmission processes. We also report an estimated dopamine diffusion coefficient two orders of magnitude smaller than that calculated by the flow-injection method.
Delafossite structure of heterogenite polytypes (HCoO2) by Raman and infrared micro-spectroscopy
NASA Astrophysics Data System (ADS)
Burlet, C.; Goethals, H.; Vanbrabant, Y.
2016-04-01
Heterogenite is commonly referred in mineralogy literature as a cobalt oxy-hydroxide CoO(OH). However, detailed analysis of Raman and infrared spectra acquired on particularly well-crystallized natural samples of heterogenite suggests that the mineral can be characterized by a delafossite-type structure, with a general chemical formula ABO2. Indeed, the Raman spectrum of heterogenite, along the one with grimaldiite (HCrO2), lacks visible free OH-group vibrational modes, while the infrared spectrum shows strong hydrogen bond absorption bands. HCoO2 is thus a better formulation of heterogenite that describes more clearly its vibrational behavior and avoids the confusion in literature. Electronic backscattered diffraction (EBSD) is then used to distinguish and map the 2H and 3R heterogenite natural polytypes for the first time. The comparison of EBSD and Raman mappings clearly indicates that the 2H polytype is characterized by an additional peak at 1220 cm- 1. The presence/absence is therefore an efficient tool to distinguish both polytypes.
Functionalization of SBA-15 mesoporous silica by Cu-phosphonate units: Probing of synthesis route
DOE Office of Scientific and Technical Information (OSTI.GOV)
Laskowski, Lukasz, E-mail: lukasz.laskowski@kik.pcz.pl; Czestochowa University of Technology, Institute of Physics, Al. Armii Krajowej 19, 42-201 Czestochowa; Laskowska, Magdalena, E-mail: magdalena.laskowska@onet.pl
2014-12-15
Mesoporous silica SBA-15 containing propyl-copper phosphonate units was investigated. The structure of mesoporous samples was tested by N{sub 2} isothermal sorption (BET and BHJ analysis), TEM microscopy and X-Ray scattering. Quantitative analysis EDX has given information about proportions between component atoms in the sample. Quantitative elemental analysis has been carried out to support EDX. To examine bounding between copper atoms and phosphonic units the Raman spectroscopy was carried out. As a support of Raman scattering, the theoretical calculations were made based on density functional theory, with the B3LYP method. By comparison of the calculated vibrational spectra of the molecule withmore » experimental results, distribution of the active units inside silica matrix has been determined. - Graphical abstract: The present study is devoted to mesoporous silica SBA-15 containing propyl-copper phosphonate units. The species were investigated to confirm of synthesis procedure correctness by the micro-Raman technique combined with DFT numerical simulations. Complementary research was carried out to test the structure of mesoporous samples. - Highlights: • SBA-15 silica functionalized with propyl-copper phosphonate units was synthesized. • Synthesis efficiency probed by Raman study supported with DFT simulations. • Homogenous distribution of active units was proved. • Synthesis route enables precise control of distance between copper ions.« less
Raman spectroscopy as a PAT for pharmaceutical blending: Advantages and disadvantages.
Riolo, Daniela; Piazza, Alessandro; Cottini, Ciro; Serafini, Margherita; Lutero, Emilio; Cuoghi, Erika; Gasparini, Lorena; Botturi, Debora; Marino, Iari Gabriel; Aliatis, Irene; Bersani, Danilo; Lottici, Pier Paolo
2018-02-05
Raman spectroscopy has been positively evaluated as a tool for the in-line and real-time monitoring of powder blending processes and it has been proved to be effective in the determination of the endpoint of the mixing, showing its potential role as process analytical technology (PAT). The aim of this study is to show advantages and disadvantages of Raman spectroscopy with respect to the most traditional HPLC analysis. The spectroscopic results, obtained directly on raw powders, sampled from a two-axis blender in real case conditions, were compared with the chromatographic data obtained on the same samples. The formulation blend used for the experiment consists of active pharmaceutical ingredient (API, concentrations 6.0% and 0.5%), lactose and magnesium stearate (as excipients). The first step of the monitoring process was selecting the appropriate wavenumber region where the Raman signal of API is maximal and interference from the spectral features of excipients is minimal. Blend profiles were created by plotting the area ratios of the Raman peak of API (A API ) at 1598cm -1 and the Raman bands of excipients (A EXC ), in the spectral range between 1560 and 1630cm -1 , as a function of mixing time: the API content can be considered homogeneous when the time-dependent dispersion of the area ratio is minimized. In order to achieve a representative sampling with Raman spectroscopy, each sample was mapped in a motorized XY stage by a defocused laser beam of a micro-Raman apparatus. Good correlation between the two techniques has been found only for the composition at 6.0% (w/w). However, standard deviation analysis, applied to both HPLC and Raman data, showed that Raman results are more substantial than HPLC ones, since Raman spectroscopy enables generating data rich blend profiles. In addition, the relative standard deviation calculated from a single map (30 points) turned out to be representative of the degree of homogeneity for that blend time. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
1996-01-01
Under a Small Business Innovation Research (SBIR) contract to Kennedy Space Center, EIC Laboratories invented a Raman Spectrograph with fiber optic sampling for space applications such as sensing hazardous fuel vapors and making on-board rapid analyses of chemicals and minerals. Raman spectroscopy is a laser-based measurement technique that provides through a unique vibrational spectrum a molecular 'fingerprint,' and can function in aqueous environments. EIC combined optical fiber technology with Raman methods to develop sensors that can be operated at a distance from the spectrographic analysis instruments and the laser excitation source. EIC refined and commercialized the technology to create the Fiber Optic Raman Spectrograph and the RamanProbe. Commercial applications range from process control to monitoring hazardous materials.
Esmonde-White, Karen A; Cuellar, Maryann; Uerpmann, Carsten; Lenain, Bruno; Lewis, Ian R
2017-01-01
Adoption of Quality by Design (QbD) principles, regulatory support of QbD, process analytical technology (PAT), and continuous manufacturing are major factors effecting new approaches to pharmaceutical manufacturing and bioprocessing. In this review, we highlight new technology developments, data analysis models, and applications of Raman spectroscopy, which have expanded the scope of Raman spectroscopy as a process analytical technology. Emerging technologies such as transmission and enhanced reflection Raman, and new approaches to using available technologies, expand the scope of Raman spectroscopy in pharmaceutical manufacturing, and now Raman spectroscopy is successfully integrated into real-time release testing, continuous manufacturing, and statistical process control. Since the last major review of Raman as a pharmaceutical PAT in 2010, many new Raman applications in bioprocessing have emerged. Exciting reports of in situ Raman spectroscopy in bioprocesses complement a growing scientific field of biological and biomedical Raman spectroscopy. Raman spectroscopy has made a positive impact as a process analytical and control tool for pharmaceutical manufacturing and bioprocessing, with demonstrated scientific and financial benefits throughout a product's lifecycle.
ERIC Educational Resources Information Center
Parobek, David; Shenoy, Ganesh; Zhou, Feng; Peng, Zhenbo; Ward, Michelle; Liu, Haitao
2016-01-01
In this upper-level undergraduate experiment, students utilize micro-Raman spectroscopy to characterize graphene prepared by mechanical exfoliation and chemical vapor deposition (CVD). The mechanically exfoliated samples are prepared by the students while CVD graphene can be purchased or obtained through outside sources. Owing to the intense Raman…
1064nm FT-Raman spectroscopy for investigations of plant cell walls and other biomass materials
Umesh P. Agarwal
2014-01-01
Raman spectroscopy with its various special techniques and methods has been applied to study plant biomass for about 30 years. Such investigations have been performed at both macro- and micro-levels. However, with the availability of the Near Infrared (NIR) (1064 nm) Fourier Transform (FT)-Raman instruments where, in most materials, successful fluorescence suppression...
Data analysis in Raman measurements of biological tissues using wavelet techniques
NASA Astrophysics Data System (ADS)
Gaeta, Giovanni M.; Zenone, Flora; Camerlingo, Carlo; Riccio, Roberto; Moro, Gianfranco; Lepore, Maria; Indovina, Pietro L.
2005-03-01
Raman spectroscopy of oral tissues is a promising tool for in vivo diagnosis of oral pathologies, due to the high chemical and structural information content of Raman spectra. However, measurements on biological tissues are usually hindered by low level signals and by the presence of interfering noise and background components due to light diffusion or fluorescence processes. Numerical methods can be used in data analysis, in order to overcome these problems. In this work the wavelet multicomponent decomposition approach has been tested in a series of micro-Raman measurements performed on "in vitro" animal tissue samples. The experimental set-up was mainly composed by a He-Ne laser and a monochromator equipped with a liquid nitrogen cooled CCD equipped with a grating of 1800 grooves/mm. The laser light was focused on the sample surface by means of a 50 X optical objective. The resulting spectra were analysed using a wavelet software package and the contribution of different vibration modes have been singled out. In particular, the C=C stretching mode, and the CH2 bending mode of amide I and amide III and tyrosine contributions were present. The validity of wavelet approach in the data treatment has been also successfully tested on aspirin.
Vilela, D.; Hortelao, A. C.; Balderas-Xicohténcatl, R.; Hirscher, M.; Hahn, K.
2017-01-01
Self-propelled micro/nano-devices have been proved as powerful tools in various applications given their capability of both autonomous motion and on-demand task fulfilment. Tubular micro-jets stand out as an important member in the family of self-propelled micro/nano-devices and are widely explored with respect to their fabrication and functionalization. A few methods are currently available for the fabrication of tubular micro-jets, nevertheless there is still a demand to explore the fabrication of tubular micro-jets made of versatile materials and with the capability of multi-functionalization. Here, we present a facile strategy for the fabrication of mesoporous silica micro-jets (MSMJs) for tubular micromotors which can carry out multiple tasks depending on their functionalities. The synthesis of MSMJs does not require the use of any equipment, making it facile and cost-effective for future practical use. The MSMJs can be modified inside, outside or both with different kinds of metal nanoparticles, which provide these micromotors with a possibility of additional properties, such as the anti-bacterial effect by silver nanoparticles, or biochemical sensing based on surface enhanced Raman scattering (SERS) by gold nanoparticles. Because of the high porosity, high surface area and also the easy surface chemistry process, the MSMJs can be employed for the efficient removal of heavy metals in contaminated water, as well as for the controlled and active drug delivery, as two proof-of-concept examples of environmental and biomedical applications, respectively. Therefore, taking into account the new, simple and cheap method of fabrication, highly porous structure, and multiple functionalities, the mesoporous silica based micro-jets can serve as efficient tools for desired applications. PMID:28891580
NASA Astrophysics Data System (ADS)
Bersani, Danilo; Antonioli, Gianni; Lottici, Pier Paolo; Casoli, Antonella
2003-08-01
Micro-Raman spectroscopy, combined with gas chromatography and ultra-violet fluorescence photography, was used to study some wall paintings in the S. Giovanni Evangelista Abbey in Parma, Italy. The restoration of some painted chapels enabled a comparison between two painters of the 16th century: Parmigianino (Girolamo Francesco Maria Mazzola, 1503-1540) and Michelangelo Anselmi (1492?-1556?). Micro-Raman spectroscopy determined the palette used by the artists, leading to the identification of different white, yellow, red, brown, green, blue and black pigments. Some pigments are evidence of later restorations. Gas chromatography combined with mass spectroscopy revealed the presence of organic binding media and enabled to distinguish between fresco and secco paintings.
Abrego, Zuriñe; Grijalba, Nagore; Unceta, Nora; Maguregui, Maite; Sanchez, Alicia; Fernández-Isla, Alberto; Goicolea, M Aranzazu; Barrio, Ramón J
2014-12-07
A method based on scanning laser ablation and inductively coupled plasma-mass spectrometry (SLA-ICPMS) and Raman micro-spectroscopy for the detection and identification of compounds consistent with gunshot residue particles (GSR) has been developed. The method has been applied to the characterization of particles resulting from the discharge of firearms using lead-free ammunition. Modified tape lifts were used to collect the inorganic and organic residues from skin surfaces in a single sample. Using SLA-ICPMS, aggregates related to the composition of the ammunition, such as Cu-Zn-Sn, Zr-Sr, Cu-Zn, Al-Ti, or Al-Sr-Zr were detected, but this composition is only consistent with GSR from lead-free ammunitions. Additional evidence was provided by micro-Raman spectroscopy, which identified the characteristic organic groups of the particles as centralite, diphenylamine or their nitrated derivatives, which are indicative of GSR.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ivanov, Victor G.; Georgi Nadjakov Institute of Solid State Physics, BAS, 72 Tzarigradsko Chaussee, 1784 Sofia; Vlakhov, Emil S.
2015-11-28
The chemical modification of the niobium (Nb) surface after irradiation with femtosecond laser pulses was investigated by scanning electron microscopy coupled with energy dispersive spectroscopy, atomic force microscopy, grazing incidence X-ray diffraction, and micro-Raman spectroscopy. The physical-chemical analyses indicated that the laser treatment results in oxidation of the Nb surface, as well as in the formation of Nb hydrides. Remarkably, after the samples' washing in ethanol, a strong Surface-Enhanced Raman Scattering (SERS) signal originating from the toluene residual traces was evidenced. Further, it was observed that the laser irradiated Nb surface is able to provide a SERS enhancement of ∼1.3 × 10{supmore » 3} times for rhodamine 6G solutions. Thus, for the first time it was shown that Nb/Nb oxide surfaces could exhibit SERS functionality, and so one can expect applications in biological/biochemical screening or for sensing of dangerous environmental substances.« less
Wang, Alan X.; Kong, Xianming
2015-01-01
Surface-enhanced Raman scattering (SERS) has demonstrated single-molecule sensitivity and is becoming intensively investigated due to its significant potential in chemical and biomedical applications. SERS sensing is highly dependent on the substrate, where excitation of the localized surface plasmons (LSPs) enhances the Raman scattering signals of proximate analyte molecules. This paper reviews research progress of SERS substrates based on both plasmonic materials and nano-photonic structures. We first discuss basic plasmonic materials, such as metallic nanoparticles and nano-rods prepared by conventional bottom-up chemical synthesis processes. Then, we review rationally-designed plasmonic nano-structures created by top-down approaches or fine-controlled synthesis with high-density hot-spots to provide large SERS enhancement factors (EFs). Finally, we discuss the research progress of hybrid SERS substrates through the integration of plasmonic nano-structures with other nano-photonic devices, such as photonic crystals, bio-enabled nanomaterials, guided-wave systems, micro-fluidics and graphene. PMID:26900428
Wang, Alan X; Kong, Xianming
2015-06-01
Surface-enhanced Raman scattering (SERS) has demonstrated single-molecule sensitivity and is becoming intensively investigated due to its significant potential in chemical and biomedical applications. SERS sensing is highly dependent on the substrate, where excitation of the localized surface plasmons (LSPs) enhances the Raman scattering signals of proximate analyte molecules. This paper reviews research progress of SERS substrates based on both plasmonic materials and nano-photonic structures. We first discuss basic plasmonic materials, such as metallic nanoparticles and nano-rods prepared by conventional bottom-up chemical synthesis processes. Then, we review rationally-designed plasmonic nano-structures created by top-down approaches or fine-controlled synthesis with high-density hot-spots to provide large SERS enhancement factors (EFs). Finally, we discuss the research progress of hybrid SERS substrates through the integration of plasmonic nano-structures with other nano-photonic devices, such as photonic crystals, bio-enabled nanomaterials, guided-wave systems, micro-fluidics and graphene.
Gandolfi, Maria Giovanna; Taddei, Paola; Tinti, Anna; De Stefano Dorigo, Elettra; Rossi, Piermaria Luigi; Prati, Carlo
2010-12-01
The bioactivity of calcium silicate mineral trioxide aggregate (MTA) cements has been attributed to their ability to produce apatite in presence of phosphate-containing fluids. This study evaluated surface morphology and chemical transformations of an experimental accelerated calcium-silicate cement as a function of soaking time in different phosphate-containing solutions. Cement discs were immersed in Dulbecco's phosphate-buffered saline (DPBS) or Hank's balanced salt solution (HBSS) for different times (1-180 days) and analysed by scanning electron microscopy connected with an energy dispersive X-ray analysis (SEM-EDX) and micro-Raman spectroscopy. SEM-EDX revealed Ca and P peaks after 14 days in DPBS. A thin Ca- and P-rich crystalline coating layer was detected after 60 days. A thicker multilayered coating was observed after 180 days. Micro-Raman disclosed the 965-cm(-1) phosphate band at 7 days only on samples stored in DPBS and later the 590- and 435-cm(-1) phosphate bands. After 60-180 days, a layer approximately 200-900 μm thick formed displaying the bands of carbonated apatite (at 1,077, 965, 590, 435 cm(-1)) and calcite (at 1,088, 713, 280 cm(-1)). On HBSS-soaked, only calcite bands were observed until 90 days, and just after 180 days, a thin apatite-calcite layer appeared. Micro-Raman and SEM-EDX demonstrated the mineralization induction capacity of calcium-silicate cements (MTAs and Portland cements) with the formation of apatite after 7 days in DPBS. Longer time is necessary to observe bioactivity when cements are immersed in HBSS.
Zhang, Ying; Wang, Yong
2012-01-01
Objective To investigate the influence of application mode on the interfacial morphology and chemistry between dentin and self-etch adhesives with different aggressiveness. Methods The occlusal one-third of the crown was removed from un-erupted human third molars, followed by abrading with 600 grit SiC under water. Rectangular dentin slabs were prepared by sectioning the tooth specimens perpendicular to the abraded surfaces. The obtained dentin slabs were treated with one of the two one-step self-etch adhesives: Adper Easy Bond (AEB, PH~2.5) and Adper Prompt L-Pop (APLP, PH~0.8) with (15s, active application) or without (15s, inactive application) agitation. The dentin slabs were fractured and the exposed adhesive/dentin (A/D) interfaces were examined with micro-Raman spectroscopy and scanning electron microscopy (SEM). Results The interfacial morphology, degree of dentin demineralization (DD) and degree of conversion (DC) of the strong self-etch adhesive APLP showed more significant dependence on the application mode than the mild AEB. APLP exhibited inferior bonding at the A/D interface if applied without agitation, evidenced by debonding from the dentin substrate. The DDs and DCs of the APLP with agitation were higher than those of without agitation in the interface, in contrast to the comparable DD and DC values of two AEB specimen groups with different application modes. Raman spectral analysis revealed the important role of chemical interaction between acid monomers of self-etch adhesives and dentin in the above observations. Conclusion The chemical interaction with dentin is especially important for improving the DC of the strong self-etching adhesive at the A/D interface. Agitation could benefit polymerization efficacy of the strong self-etch adhesive through enhancing the chemical interaction with tooth substrate. PMID:23153573
Yu, Borong; Cao, Chentai; Li, Pan; Mao, Mei; Xie, Qiwen; Yang, Liangbao
2018-08-15
Morphine, a kind of illicit drugs, is also one of the main heroin metabolites. In consideration of a noninvasive way to monitor and identify drug abuse during forensic cases, the urine samples are usually detected. Here, colloidal gold nanorods (Au NRs) were introduced to act as active substrate, because of the strong optical extinction and spectral tunability of the longitudinal surface plasmon resonance (SPR). Thus, well surface-enhanced Raman spectra of morphine even at low concentrations could be obtained by portable Raman spectrometer. For the complex matrix environment of urine, liquid-liquid micro-extraction (LLME), a simple and inexpensive pretreatment, was employed to avoid the interferences. And then, the coupled surface-enhanced Raman spectroscopy (SERS) can give full play to the advantages of high sensitivity and unique spectroscopic fingerprint. According to the zwitterionic structure and physicochemical parameters of morphine molecules, the pH value of urine sample was adjusted to about 9 by buffer solution (KOH/NaB 4 O 7 ) and the mixture of chloroform and isopropyl alcohol (V/V=9:1) was chosen as extractant. Moreover, such pretreatment was proved to be appropriate for separation and concentration of morphine from urine. The developed LLME-SERS method could provide a detection limit less than 1 ppm in the human urine environment and the whole process of detection just needed take 5-6 min. What's more, the results of urine samples from heroin users exhibited application value of the proposed technique. The excellent performance makes it promising to become a rapid, reliable, and on-spot analyzer, especially for public safety and healthcare. Copyright © 2018 Elsevier B.V. All rights reserved.
Kuramochi, Erika; Iizuka, Junko; Mukai, Yoshiharu
2016-12-01
In the present study, we investigated, using micro-Raman spectroscopy (Raman) and transverse microradiography, the influence of bicarbonate [sodium hydrogen carbonate (NaHCO 3 )] on the effects of carbonate ions in the mineral phase during demineralization (acid resistance test) of subsurface lesions. Baseline lesions were created by demineralizing bovine enamel, and specimens were then exposed to remineralization solutions containing 0, 5, or 50 mM bicarbonate. Acid resistance tests were performed on remineralized and sound enamel specimens. Raman spectra showed that carbonate and phosphate were incorporated into both surface layers and lesion bodies during remineralization in the presence of bicarbonate. Moreover, the presence of bicarbonate did not affect the rates of remineralization, although the average mineral profiles of remineralized enamel differed from those of sound enamel after acid resistance tests. Raman analyses enabled close evaluation of site-specific characteristics of carbonate and phosphate in subsurface lesions. In conclusion, incorporation of carbonate and phosphate ions into enamel subsurface lesions during remineralization does not affect the magnitude of remineralization or acid resistance. © 2016 Eur J Oral Sci.
Deformation mechanisms in advanced structural ceramics due to indentation and scratch processes
NASA Astrophysics Data System (ADS)
Ghosh, Dipankar
Plasma pressure compaction technique was used to develop boron carbide (B4C) and zirconium diboride-silicon carbide (ZrB2-SiC) composite. B4C ceramics are extensively used as body armor in military and civilian applications, and ZrB2-SiC composite has been recognized as a potential candidate for high-temperature aerospace applications. In this dissertation, processing parameters, quasistatic and high-strain rate mechanical response, and fundamental deformation mechanisms of these materials have been investigated. In the case of B4C, the rate sensitivity of indentation hardness was determined using a dynamic indentation hardness tester that can deliver loads in 100 micros. By comparing dynamic hardness with the static hardness, it was found that B4C exhibits a lower hardness at high-strain rate, contrary to known behavior in many structural ceramics. However, these results are consistent with the ballistic testing of B4C armors as reported in recent literature. This behavior was further investigated using a series of spectroscopic techniques such as visible and UV micro-Raman, photoluminescence and infrared. These studies not only confirmed that structural transformation occurred during indentation experiments similar to that in ballistic testing of B4C but also suggested a greater degree of structural changes under dynamic loading compared to static loading. Due to the potential application as external heat shields in supersonic vehicles, scratch studies were conducted on the ZrB2-SiC composite. These studies revealed metal-like slip-line patterns which are indeed an unusual in brittle solids at room-temperature. Utilizing classical stress field solutions under combined normal and tangential loads, a rationale was developed for understanding the formation of scratch-induced deformation features. Also, an analytical framework was developed, combining the concept of 'blister field' and the 'secular equation' relating Raman peaks to strain, to measure scratch-induced residual stress employing micro-Raman spectroscopy. Transmission electron microscopic investigations confirmed the existence of dislocations within the ZrB2 phase. It has been argued here that readily detectable slipline patterns are reflection of metallicity in chemical bonding present in ZrB2 ceramics which has also been suggested in recent literature from chemical bonding and electronic structure investigations.
Measurements of Raman crystallinity profiles in thin-film microcrystalline silicon solar cells
NASA Astrophysics Data System (ADS)
Choong, G.; Vallat-Sauvain, E.; Multone, X.; Fesquet, L.; Kroll, U.; Meier, J.
2013-06-01
Wedge-polished thin film microcrystalline silicon solar cells are prepared and used for micro-Raman measurements. Thereby, the variations of the Raman crystallinity with depth are accessed easily. Depth resolution limits of the measurement set-up are established and calculations evidencing the role of optical limits are presented. Due to this new technique, Raman crystallinity profiles of two microcrystalline silicon cells give first hints for the optimization of the profile leading to improved electrical performance of such devices.
Raman spectroscopy on ice cores from Greenland and Antarctica
NASA Astrophysics Data System (ADS)
Weikusat, C.; Kipfstuhl, S.
2012-04-01
Ice cores are invaluable archives for the reconstruction of the climatic history of the earth. Besides the analysis of various climatic processes from isotopes and chemical signatures they offer the unique possibility of directly extracting the past atmosphere from gaseous inclusions in the ice. Many aspects of the formation and alterations of these inclusions, e.g. the entrapment of air at the firn-ice-transition, the formation of crystalline gas hydrates (clathrates) from the bubbles or the structural relaxation during storage of the cores, need to be better understood to enable reliable interpretations of the obtained data. Modern micro Raman spectroscopy is an excellent tool to obtain high-quality data for all of these aspects. It has been productively used for phase identification of solid inclusions [1], investigation of air clathrates [2] and high-resolution measurements of N2/O2 mixing ratios inside individual air bubbles [3,4]. Detailed examples of the various uses of Raman spectroscopy will be presented along with practical information about the techniques required to obtain high-quality spectra. Retrieval and interpretation of quantitative data from the spectra will be explained. Future possibilities for advanced uses of Raman spectroscopy for ice core research will be discussed. [1] T. Sakurai et al., 2009, Direct observation of salts as micro-inclusions in the Greenland GRIP ice core. Journal of Glaciology, 55, 777-783. [2] F. Pauer et al., 1995, Raman spectroscopic study of nitrogen/oxygen ratio in natural ice clathrates in the GRIP ice core. Geophysical Research Letters, 22, 969-971. [3] T. Ikeda-Fukazawa et al., 2001, Variation in N2/O2 ratio of occluded air in Dome Fuji antarctic ice. Journal of Geophysical Research, 106, 17799-17810. [4] C. Weikusat et al., Raman spectroscopy of gaseous inclusions in EDML ice core: First results - microbubbles. Journal of Glaciology, accepted.
NASA Astrophysics Data System (ADS)
Narazaki, Aiko; Kurosaki, Ryozo; Sato, Tadatake; Kawaguchi, Yoshizo; Niino, Hiroyuki
2007-02-01
We printed FeSi II micro-dot array on various kinds of substrates utilizing laser-induced forward transfer (LIFT). An amorphous FeSi II was deposited by sputtering on a transparent plate as a source film. A single KrF excimer laser pulse through a mask-projection system was imaged with a small micrometer-sized grid pattern onto a film/plate interface, resulting in the deposition of FeSi II micro-dot array on a facing substrate with a high number density of 10 4 mm -2. FeSi II in the β crystalline phase is a promising eco-friendly semiconductor because of NIR electroluminescence used for optical networking as well as abundant components reserve on the earth and non-toxicity. However, the β-FeSi II film fabrication generally required high-temperature multi-processes which hamper its integration and performance reproducibility. Using the LIFT of micro-dot array, we succeeded in room-temperature preparation of β-FeSi II. Micro-Raman spectroscopy confirmed the β crystalline phase in the micro-dots deposited on an unheated silica glass substrate. Thus, the LIFT is useful for integrating functional micro-dot array accompanied by the crystallization at lower temperatures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moore, Samuel L.; Samudrala, Gopi K.; Catledge, Shane A.
Early stage nucleation morphologies of spatially localized nanocrystalline diamond (NCD) micro-anvils grown on (100)-oriented single crystal diamond (SCD) anvil surfaces were analyzed and investigated for applications in high pressure studies on materials. NCD was grown on SCD using Microwave Plasma Chemical Vapor Deposition (MPCVD) for brief time intervals ranging from 1-15 minutes. Early stage film morphologies were characterized using scanning electron microscopy (SEM) and Raman spectroscopy and were compared to films grown for several hours. Rapid nucleation and growth of NCD on SCD is demonstrated without any pre-growth seeding of the substrate surface. As grown NCD diamond micro-anvils on SCDmore » were used to generate static pressure of 0.5 Terapascal (TPa) on a tungsten sample as measured by synchrotron x-ray diffraction in a diamond anvil cell. Atomic force microscopy (AFM) analysis after decompression from ultrahigh pressures showed that the detachment of the NCD stage occurred in the bulk of the SCD and not at the interface, suggesting significant adhesive bond strength between nanocrystalline and single crystal diamond.« less
Moore, Samuel L.; Samudrala, Gopi K.; Catledge, Shane A.; ...
2018-01-23
Early stage nucleation morphologies of spatially localized nanocrystalline diamond (NCD) micro-anvils grown on (100)-oriented single crystal diamond (SCD) anvil surfaces were analyzed and investigated for applications in high pressure studies on materials. NCD was grown on SCD using Microwave Plasma Chemical Vapor Deposition (MPCVD) for brief time intervals ranging from 1-15 minutes. Early stage film morphologies were characterized using scanning electron microscopy (SEM) and Raman spectroscopy and were compared to films grown for several hours. Rapid nucleation and growth of NCD on SCD is demonstrated without any pre-growth seeding of the substrate surface. As grown NCD diamond micro-anvils on SCDmore » were used to generate static pressure of 0.5 Terapascal (TPa) on a tungsten sample as measured by synchrotron x-ray diffraction in a diamond anvil cell. Atomic force microscopy (AFM) analysis after decompression from ultrahigh pressures showed that the detachment of the NCD stage occurred in the bulk of the SCD and not at the interface, suggesting significant adhesive bond strength between nanocrystalline and single crystal diamond.« less
Micro-Raman spectroscopy of gem-quality chrysoprase from the Biga-Çanakkale region of Turkey
NASA Astrophysics Data System (ADS)
Hatipoğlu, Murat; Ören, Ufuk; Kibici, Yaşar
2011-11-01
The commercial quantities of gem-quality dark green chrysoprase are found as the fracture fillings covered with a weathering crust in the silicified serpentinites throughout the border of a metamorphic zone in the Biga-Çanakkale region of Turkey. However, the green-stained opaque quartz materials are also present in the same deposit, but these materials are common and in low-demand according to chrysoprase in terms of gemmological importance. Thus, it is necessary to distinguish these two similar materials from each other non-destructively. In addition, all chrysoprase roughs in this deposit also have alpha-quartz and moganite inclusions. Accordingly, dispersive (visible) confocal micro-Raman spectroscopy (DCμRS) allows us to distinguish clearly the chalcedonic-quartz silica phase (fibrous quartz (chalcedony)) from the crystalline-quartz silica phase (fine-grained alpha-quartz) in the case of both quartz inclusions in the chrysoprase material and itself of the green-stained quartz material in the same deposit. This study characterizes the Biga chrysoprase (Turkey) in terms of silica building phases, chemical content, and individual Raman bands, using several destructive and non-destructive analytical techniques. The Raman spectra show that the most characteristic intensive and the widest Raman bands peaked at about 498 and 460 cm -1 can be inferred to ν2 doubly symmetric bending mode of [SiO 4/M] centers. The "M" includes the some cationic substitutions of Si by Fe, Cr, Mn, As, Ni, Pb, Sb, and Zn, and K and Na as well. The second characteristic Raman band peaked at about 206 cm -1 can be inferred to single translational libration mode. The last readable Raman bands peaked at about 139 and 126 cm -1 can be inferred to doubly translational libration modes as well. In addition, the weaker Raman bands peaked at about 1577, 1430, 1303, 1160, 1082, 549, 394, 352, and 259 cm -1 are also present. As a result, the dispersive confocal micro-Raman spectrum of chrysoprase is directly related to its silica building phases and trace element implications.
A 1064 nm dispersive Raman spectral imaging system for food safety and quality evaluation
USDA-ARS?s Scientific Manuscript database
Raman spectral imaging is an effective method to analyze and evaluate chemical composition and structure of a sample, and has many applications for food safety and quality research. This study developed a 1064 nm Raman spectral imaging system for surface and subsurface analysis of food samples. A 10...
Potassium alum and aluminum sulfate micro-inclusions in polar ice from Dome Fuji, East Antarctica
NASA Astrophysics Data System (ADS)
Ohno, Hiroshi; Iizuka, Yoshinori; Horikawa, Shinichiro; Sakurai, Toshimitsu; Hondoh, Takeo; Motoyama, Hideaki
2014-03-01
Water-soluble trace constituents affect the physicochemical properties of polar ice. Their structural distribution provides important insights into the formation history of ice and inclusions. We report the first finding of KAl(SO4)2·12H2O (potassium alum) and Al2(SO4)3·nH2O (aluminum sulfate) micro-inclusions in the Dome Fuji ice core, East Antartica, using a micro-Raman technique. Eutectic temperatures of these water-soluble species determined using thermal analysis were -0.4 °C for potassium alum and -8.0 °C for aluminum sulfate. Although the formation process of the aluminum-bearing sulfates remains unclear, the occurrence of these salts largely depends on ice depth.
NASA Astrophysics Data System (ADS)
Bruni, Silvia; Guglielmi, Vittoria; Della Foglia, Elena; Castoldi, Marina; Bagnasco Gianni, Giovanna
2018-02-01
A study is presented based on the use of entirely non-destructive spectroscopic techniques to analyze the chemical composition of the painted surface layer of archaeological pottery. This study aims to define both the raw materials and the working technology of ancient potters. Energy-dispersive X-ray analysis, micro-Raman spectroscopy, visible and near infrared (NIR) diffuse reflection spectroscopy and external reflection Fourier-transform infrared (FTIR) spectroscopy were applied to matt-painted bichrome pottery sherds (VIII-VII century B.C.) from the site of Incoronata near Metaponto in southern Italy. Two different raw materials, ochre and iron-rich clay, were recognized for the red decoration, while the dark areas resulted to have been obtained by the so-called manganese black technique. In any case, it was demonstrated that the decoration was applied before firing, in spite of its sometimes grainy aspect that could suggest a post-firing application. For the samples with a more sophisticated decorative pattern a red/black/white polychromy was recognized, as the lighter areas correspond to an ;intentional white; obtained by the firing of a calcium-rich clay. Reflection spectroscopy in the visible-NIR and mid-IR as well as micro-Raman spectroscopy were then employed to characterize the decoration of an intact ceramic urn from the Etruscan town of Chiusi, evidencing a post-firing painting based on the use of red ochre, carbon black and lime, possibly imitating the ;fresco; technique used in wall paintings.
NASA Astrophysics Data System (ADS)
Zhang, Haibao; Wang, Jingjing; Wang, Hua; Tian, Xingyou
2017-09-01
In this paper, we presented the fabrication of mace-like gold hollow hierarchical micro/nanostructures (HMNs) grafted on ZnO nanorods array by using an electrochemical deposition in chloroauric acid solution on gold layer pre-coated ZnO nanorods array. Different from general electrochemical deposition process, the catalytic etching to ZnO and electrodeposition of gold are co-existed in our case, which lead to an inner hollow structure and an outer gold shell. Due to the appropriate electrodeposition conditions, the outer gold shell was built of many wimble-like nanoparticles, and the hierarchical micro/nanostructures were thus formed. In addition, because of the deposition rate is decreased gradually away from the top of ZnO nanorods, the final structures show mace-like appearance. The surface-enhanced Raman scattering (SERS) effect of the as-prepared gold hollow HMNs was further studied by using rhodamine 6G as probe molecule. It is demonstrated that these structures show ultrahigh SERS activity, and the detecting low limit of R6G solution can be to 10-10 M on single mace-like gold HMNs, which is quite important for their potential application in SERS-based surface analysis and sensors.
Extending Raman's reach: enabling applications via greater sensitivity and speed
NASA Astrophysics Data System (ADS)
Creasey, David; Sullivan, Mike; Paul, Chris; Rathmell, Cicely
2018-02-01
Over the last decade, miniature fiber optic spectrometers have greatly expanded the ability of Raman spectroscopy to tackle practical applications in the field, from mobile pharmaceutical ID to hazardous material assessment in remote locations. There remains a gap, however, between the typical diode array spectrometer and their more sensitive benchtop analogs. High sensitivity, cooled Raman spectrometers have the potential to narrow that gap by providing greater sensitivity, better SNR, and faster measurement times. In this paper, we'll look at the key factors in the design of high sensitivity miniature Raman spectrometers and their associated accessories, as well as the key metric for direct comparison of these systems - limit of detection. With the availability of our high sensitivity Raman systems operating at wavelengths from the UV to NIR, many applications are now becoming practical in the field, from trace level detection to analysis of complex biological samples.
NASA Astrophysics Data System (ADS)
Shi, Tian; Kong, Jianyi; Wang, Xingdong; Li, Xuewu
2016-12-01
A superamphiphobic aluminum magnesium alloy surface with enhanced anticorrosion behavior has been prepared in this work via a simple and low-cost method. By successively polishing, etching and boiling treatments, the multifunctional hierarchical binary structures composed of the labyrinth-like concave-convex microstructures and twisty nanoflakes have been prepared. Results indicate that a superhydrophobic contact angle of 160.5° and superoleophobic contact angle larger than 150° as well as low adhesive property to liquids are achieved after such structures being modified with fluoroalkyl-silane. Furthermore, the anticorrosion behaviors in seawater of as-prepared samples are characterized by electrochemical tests including the impedance spectroscopies, equivalent circuits fittings and polarization curves. It is found that the hierarchical micro/nanostructures accompanying with the modified coating are proved to possess the maximal coating coverage rate of 90.0% larger than microstructures of 85.9%, nanostructures of 83.8% and bare polished surface of 67.1% suggesting the optimal anticorrosion. Finally, a great potential application in concentrators for surface-enhanced Raman scattering (SERS) analysis of toxic and pollutive ions on the superamphiphobic surface is also confirmed. This work has wider significance in extending further applications of alloys in engineering and environmental detecting fields.
Micro-Raman spectroscopy of algae: composition analysis and fluorescence background behavior.
Huang, Y Y; Beal, C M; Cai, W W; Ruoff, R S; Terentjev, E M
2010-04-01
Preliminary feasibility studies were performed using Stokes Raman scattering for compositional analysis of algae. Two algal species, Chlorella sorokiniana (UTEX #1230) and Neochloris oleoabundans (UTEX #1185), were chosen for this study. Both species were considered to be candidates for biofuel production. Raman signals due to storage lipids (specifically triglycerides) were clearly identified in the nitrogen-starved C. sorokiniana and N. oleoabundans, but not in their healthy counterparts. On the other hand, signals resulting from the carotenoids were found to be present in all of the samples. Composition mapping was conducted in which Raman spectra were acquired from a dense sequence of locations over a small region of interest. The spectra obtained for the mapping images were filtered for the wavelengths of characteristic peaks that correspond to components of interest (i.e., triglyceride or carotenoid). The locations of the components of interest could be identified by the high intensity areas in the composition maps. Finally, the time evolution of fluorescence background was observed while acquiring Raman signals from the algae. The time dependence of fluorescence background is characterized by a general power law decay interrupted by sudden high intensity fluorescence events. The decreasing trend is likely a result of photo-bleaching of cell pigments due to prolonged intense laser exposure, while the sudden high intensity fluorescence events are not understood. (c) 2009 Wiley Periodicals, Inc.
Raman studies of the interactions of fibrous carbon nanomaterials with albumin
NASA Astrophysics Data System (ADS)
Wesełucha-Birczyńska, Aleksandra; Morajka, Krzysztof; Stodolak-Zych, Ewa; Długoń, Elżbieta; Dużyja, Maria; Lis, Tomasz; Gubernat, Maciej; Ziąbka, Magdalena; Błażewicz, Marta
2018-05-01
Adsorption or immobilization of proteins on synthetic surfaces is a key issue in the context of the biocompatibility of implant materials, especially those intended for the needs of cardiac surgery but also for the construction of biosensors or nanomaterials used as drug carriers. The subject of research was the analysis of Raman spectra of two types of fibrous carbon nanomaterials, of great potential for biomedical applications, incubated with human serum albumin (HSA). The first nanomaterial has been created on the layer of MWCNTs deposited by electrophoretic method (EPD) and then covered by thin film of pyrolytic carbon introduced by chemical vapor deposition process (CVD). The second material was formed from carbonized nanofibers prepared via electrospinning (ESCNFs) of polyacrylonitrile (PAN) precursor and then covered with pyrolytic carbon (CVD). The G-band blue-shift towards the position of about 1600 cm-1, observed for both studied surfaces, clearly indicates the albumin (HSA) adhesion to the surface. The G and G' (2D) peak shift was employed to assess the stress build up on the carbon nanomaterials. The surface nano- and micro-topography as well as the method of ordering the carbon nanomaterial has a significant influence on the mode of surface-protein interaction.
Micro-Raman investigations of InN-GaN core-shell nanowires on Si (111) substrate
NASA Astrophysics Data System (ADS)
Sangeetha, P.; Jeganathan, K.; Ramakrishnan, V.
2013-06-01
The electron-phonon interactions in InN-GaN core-shell nanowires grown by plasma assisted- molecular beam epitaxy (MBE) on Si (111) substrate have been analysed using micro-Raman spectroscopic technique with the excitation wavelength of 633, 488 and 325 nm. The Raman scattering at 633 nm reveals the characteristic E2 (high) and A1 (LO) phonon mode of InN core at 490 and 590 cm-1 respectively and E2 (high) phonon mode of GaN shell at 573 cm-1. The free carrier concentration of InN core is found to be low in the order ˜ 1016 cm-3 due to the screening of charge carriers by thin GaN shell. Diameter of InN core evaluated using the spatial correlation model is consistent with the transmission electron microscopic measurement of ˜15 nm. The phonon-life time of core-shell nanowire structure is estimated to be ˜0.4 ps. The micro-Raman mapping and its corresponding localised spectra for 325 nm excitation exhibit intense E2 (high) phonon mode of GaN shell at 573 cm-1 as the decrease of laser interaction length and the signal intensity is quenched at the voids due to high spacing of NWs.
Surface-Enhanced Raman Scattering Using Silica Whispering-Gallery Mode Resonators
NASA Technical Reports Server (NTRS)
Anderson, Mark S.
2013-01-01
The motivation of this work was to have robust spectroscopic sensors for sensitive detection and chemical analysis of organic and molecular compounds. The solution is to use silica sphere optical resonators to provide surface-enhanced spectroscopic signal. Whispering-gallery mode (WGM) resonators made from silica microspheres were used for surface-enhanced Raman scattering (SERS) without coupling to a plasmonic mechanism. Large Raman signal enhancement is observed by exclusively using 5.08-micron silica spheres with 785-nm laser excitation. The advantage of this non-plasmonic approach is that the active substrate is chemically inert silica, thermally stable, and relatively simple to fabricate. The Raman signal enhancement is broadly applicable to a wide range of molecular functional groups including aliphatic hydrocarbons, siloxanes, and esters. Applications include trace organic analysis, particularly for in situ planetary instruments that require robust sensors with consistent response.
Wang, Q; Liu, X; Kibria, M G; Zhao, S; Nguyen, H P T; Li, K H; Mi, Z; Gonzalez, T; Andrews, M P
2014-09-07
Micro-Raman scattering and X-ray photoelectron spectroscopy were employed to investigate Mg-doped GaN nanowires. With the increase of Mg doping level, pronounced Mg-induced local vibrational modes were observed. The evolution of longitudinal optical phonon-plasmon coupled mode, together with detailed X-ray photoelectron spectroscopy studies, show that the near-surface region of nanowires can be transformed from weakly n-type to p-type with the increase of Mg doping.
NASA Astrophysics Data System (ADS)
Neto, Lázaro P. M.; Martin, Aírton A.; Soto, Claudio A. T.; Santos, André B. O.; Mello, Evandro S.; Pereira, Marina A.; Cernea, Cláudio R.; Brandão, Lenine G.; Canevari, Renata A.
2016-02-01
Thyroid carcinomas represent the main endocrine malignancy and their diagnosis may produce inconclusive results. Raman spectroscopy and gene expression analysis have shown excellent results on the differentiation of carcinomas. This study aimed to improve the discrimination between different thyroid pathologies combining of both analyses. A total of 35 thyroid tissues samples including normal tissue (n=10), goiter (n=10), papillary (n=10) and follicular carcinomas (n=5) were analyzed. Confocal Raman spectra was obtain by using a Rivers Diagnostic System, 785 nm laser excitation and CCD detector. The data was processed by the software Labspec5 and Origin 8.5 and analyzed by Minitab® program. The gene expression analysis was performed by qRT-PCR technique for TG, TPO, PDGFB, SERPINA1, LGALS3 and TFF3 genes and statistically analyzed by Mann-Whitney test. The confocal Raman spectroscopy allowed a maximum discrimination of 91.1% between normal and tumor tissues, 84.8% between benign and malignant pathologies and 84.6% among carcinomas analyzed. Significant differences was observed for TG, LGALS3, SERPINA1 and TFF3 genes between benign lesions and carcinomas, and SERPINA1 and TFF3 genes between papillary and follicular carcinomas. Principal component analysis was performed using PC1 and PC2 in the papillary carcinoma samples that showed over gene expression when compared with normal sample, where 90% of discrimination was observed at the Amide 1 (1655 cm-1), and at the tyrosine spectra region (856 cm-1). The discrimination of tissues thyroid carried out by confocal Raman spectroscopy and gene expression analysis indicate that these techniques are promising tools to be used in the diagnosis of thyroid lesions.
Scalable fabrication of carbon-based MEMS/NEMS and their applications: a review
NASA Astrophysics Data System (ADS)
Jiang, Shulan; Shi, Tielin; Zhan, Xiaobin; Xi, Shuang; Long, Hu; Gong, Bo; Li, Junjie; Cheng, Siyi; Huang, Yuanyuan; Tang, Zirong
2015-11-01
The carbon-based micro/nano electromechanical system (MEMS/NEMS) technique provides a powerful approach to large-scale manufacture of high-aspect-ratio carbon structures for wafer-level processing. The fabricated three-dimensional (3D) carbon structures have the advantages of excellent electrical and electrochemical properties, and superior biocompatibility. In order to improve their performance for applications in micro energy storage devices and microsensors, an increase in the footprint surface area is of great importance. Various approaches have been proposed for fabricating large surface area carbon-based structures, including the integration of nanostructures such as carbon nanotubes (CNTs), graphene, nanowires, nanofilms and nanowrinkles onto 3D structures, which has been proved to be effective and productive. Moreover, by etching the 3D photoresist microstructures through oxygen plasma or modifying the photoresist with specific materials which can be etched in the following pyrolysis process, micro/nano hierarchical carbon structures have been fabricated. These improved structures show excellent performance in various applications, especially in the fields of biological sensors, surface-enhanced Raman scattering, and energy storage devices such as micro-supercapacitors and fuel cells. With the rapid development of microelectronic devices, the carbon-based MEMS/NEMS technique could make more aggressive moves into microelectronics, sensors, miniaturized power systems, etc. In this review, the recent advances in the fabrication of micro/nano hierarchical carbon-based structures are introduced and the technical challenges and future outlook of the carbon-based MEMS/NEMS techniques are also analyzed.
Raman Gas Species Measurements in Hydrocarbon-Fueled Rocket Engine Injector Flows
NASA Technical Reports Server (NTRS)
Wehrmeyer, Joseph A.; Trinh, Huu Phuoc; Hartfield, Roy J.; Dobson, Christopher C.; Eskridge, Richard H.
2000-01-01
Propellent injector development at MSFC (Marshall Space Flight Center) includes experimental analysis using optical techniques, such as Raman, fluorescence, or Mie scattering. For the application of spontaneous Raman scattering to hydrocarbon-fueled flows a technique needs to be developed to remove the interfering polycyclic aromatic hydrocarbon fluorescence from the relatively weak Raman signals. A current application of such a technique is to the analysis of the mixing and combustion performance of multijet, impinging-jet candidate fuel injectors for the baseline Mars ascent engine, which will burn methane and liquid oxygen produced in-situ on Mars to reduce the propellent mass transported to Mars for future manned Mars missions. The present technique takes advantage of the strongly polarized nature of Raman scattering. It is shown to be discernable from unpolarized fluorescence interference by subtracting one polarized image from another. Both of these polarized images are obtained from a single laser pulse by using a polarization-separating calcite rhomb mounted in the imaging spectrograph. A demonstration in a propane-air flame is presented.
Femtosecond Laser Fabrication of Monolithically Integrated Microfluidic Sensors in Glass
He, Fei; Liao, Yang; Lin, Jintian; Song, Jiangxin; Qiao, Lingling; Cheng, Ya; Sugioka, Koji
2014-01-01
Femtosecond lasers have revolutionized the processing of materials, since their ultrashort pulse width and extremely high peak intensity allows high-quality micro- and nanofabrication of three-dimensional (3D) structures. This unique capability opens up a new route for fabrication of microfluidic sensors for biochemical applications. The present paper presents a comprehensive review of recent advancements in femtosecond laser processing of glass for a variety of microfluidic sensor applications. These include 3D integration of micro-/nanofluidic, optofluidic, electrofluidic, surface-enhanced Raman-scattering devices, in addition to fabrication of devices for microfluidic bioassays and lab-on-fiber sensors. This paper describes the unique characteristics of femtosecond laser processing and the basic concepts involved in femtosecond laser direct writing. Advanced spatiotemporal beam shaping methods are also discussed. Typical examples of microfluidic sensors fabricated using femtosecond lasers are then highlighted, and their applications in chemical and biological sensing are described. Finally, a summary of the technology is given and the outlook for further developments in this field is considered. PMID:25330047
Briviba, Karlis; Bornemann, Rainer; Lemmer, Ulrich
2006-11-01
Astaxanthin, a carotenoid found in plants and seafood, exhibits antiproliferative, antioxidant and anticarcinogenic properties. We show that astaxanthin delivered with tetrahydrofuran is effectively taken up by cultured colon adenocarcinoma cells and is localized mostly in the cytoplasm as detected by confocal resonance Raman and broad-band fluorescence microspectroscopy image analysis. Cells incubated with beta-carotene at the same concentration as astaxanthin (10 microM) showed about a 50-fold lower cellular amount of beta-carotene, as detected by HPLC. No detectable Raman signal of beta-carotene was found in cells, but a weak broad-band fluorescence signal of beta-carotene was observed. beta-Carotene, like astaxanthin, was localized mostly in the cytoplasm. The heterogeneity of astaxanthin and beta-carotene cellular distribution in cells of intestinal origin suggests that the possible defense against reactive molecules by carotenoids in these cells may also be heterogeneous.
Gamberini, M Cristina; Baraldi, C; Freguglia, G; Baraldi, P
2011-10-01
A study of the composition of the remains of ancient ointments from museums was undertaken to enable understanding of the preparation techniques. Comparison of ancient recipes from different historical periods and spectroscopic characteristics of inorganic and/or organic remains recovered in museum vessels enabled preparation of ancient pharmaceutical-cosmetic formulations. Farmacopea Augustana by Occo was one the most important books studied for the 14 formulations prepared in the laboratory. Three formulations are discussed in detail and raw materials and new preparations were proposed for ozone ageing. The most important micro Raman results are discussed. The spectra of the raw materials lipids, beeswax, and resins are discussed; beeswax and pig suet (axŭngia) Raman spectra were found to be similar, but different from those of the aged oils. SERS was applied to ancient ointments and galbanum and the Raman spectra are reported and discussed for the first time.
NASA Astrophysics Data System (ADS)
Luna-Pineda, Tatiana; Soto-Feliciano, Kristina; De La Cruz-Montoya, Edwin; Pacheco Londoño, Leonardo C.; Ríos-Velázquez, Carlos; Hernández-Rivera, Samuel P.
2007-04-01
FTIR, Raman spectroscopy and Surface Enhanced Raman Scattering (SERS) requires a minimum of sample allows fast identification of microorganisms. The use of this technique for characterizing the spectroscopic signatures of these agents and their stimulants has recently gained considerable attention due to the fact that these techniques can be easily adapted for standoff detection from considerable distances. The techniques also show high sensitivity and selectivity and offer near real time detection duty cycles. This research focuses in laying the grounds for the spectroscopic differentiation of Staphylococcus spp., Pseudomonas spp., Bacillus spp., Salmonella spp., Enterobacter aerogenes, Proteus mirabilis, Klebsiella pneumoniae, and E. coli, together with identification of their subspecies. In order to achieve the proponed objective, protocols to handle, cultivate and analyze the strains have been developed. Spectroscopic similarities and marked differences have been found for Spontaneous or Normal Raman spectra and for SERS using silver nanoparticles have been found. The use of principal component analysis (PCA), discriminate factor analysis (DFA) and a cluster analysis were used to evaluate the efficacy of identifying potential threat bacterial from their spectra collected on single bacteria. The DFA from the bacteria Raman spectra show a little discrimination between the diverse bacterial species however the results obtained from the SERS demonstrate to be high discrimination technique. The spectroscopic study will be extended to examine the spores produced by selected strains since these are more prone to be used as Biological Warfare Agents due to their increased mobility and possibility of airborne transport. Micro infrared spectroscopy as well as fiber coupled FTIR will also be used as possible sensors of target compounds.
Confocal micro-Raman spectroscopy of black soap films
NASA Astrophysics Data System (ADS)
Lecourt, B.; Capelle, F.; Adamietz, F.; Malaplate, A.; Blaudez, D.; Kellay, H.; Turlet, J. M.
1998-01-01
Black soap films from aqueous solutions of sodium dodecyl sulphate are studied by micro-Raman confocal spectroscopy. At the end of the draining process films of different thicknesses are obtained depending on the experimental conditions: Working in a closed humidified chamber leads to common black films while, under evaporation or in the presence of electrolyte, Newton black films are observed. From the Raman spectra of these films, quantitative information is deduced about the conformational and lateral order of the aliphatic surfactant chains, as well as the thickness of the residual water layer. More accurate measurements of the thickness of these ultimate films have been carried out by transmission ellipsometry and their effective refractive index measured by Brewster angle reflectivity. The thinner films present higher molecular organization and their aqueous core exhibits unusual spectral features.
NASA Astrophysics Data System (ADS)
Rosina, P.; Gomes, H.; Collado, H.; Nicoli, M.; Volpe, L.; Vaccaro, C.
2018-06-01
Micro-Raman spectroscopic technique allowed the characterization of organic and inorganic pigments of different colours sampled from a rock-art shelter named Abrigo del Aguila, located in the district of Badajoz, Cabeza del Buey (Extremadura - Spain). Micro-Raman analyses has been coupled with SEM observation and elemental analyses (EDS). The white and the black colours, used for non-representative figures, have been identified respectively as anatase and amorphous carbon, while two different type of red pigment has been found on figurative representations. The darker one, sampled, from a sun-figure, comprises an indeterminate organic compound beside of hematite. The second one, sampled from an anthropomorphic figure, is of a brilliant red and only hematite has been recognized in it.
NASA Astrophysics Data System (ADS)
Blacksberg, J.; Alerstam, E.; Maruyama, Y.; Cochrane, C.; Rossman, G. R.
2015-12-01
We present recent developments in time-resolved Raman spectroscopy for in situ planetary surface exploration, aimed at identification of both minerals and organics. Raman is a non-destructive surface technique that requires no sample preparation. Raman spectra are highly material specific and can be used for identification of a wide range of unknown samples. In combination with micro-scale imaging and point mapping, Raman spectroscopy can be used to directly interrogate rocks and regolith materials, while placing compositional analyses within a microtextural context, essential for understanding surface evolutionary pathways. Due to these unique capabilities, Raman spectroscopy is of great interest for the exploration of all rocky and icy bodies, for example Mars, Venus, the Moon, Mars' moons, asteroids, comets, Europa, and Titan. In this work, we focus on overcoming one of the most difficult challenges faced in Raman spectroscopy: interference from background fluorescence of the very minerals and organics that we wish to characterize. To tackle this problem we use time-resolved Raman spectroscopy, which separates the Raman from background processes in the time domain. This same technique also enables operation in daylight without the need for light shielding. Two key components are essential for the success of this technique: a fast solid-state detector and a short-pulse laser. Our detector is a custom developed Single Photon Avalanche Diode (SPAD) array, capable of sub-ns time-gating. Our pulsed lasers are solid-state miniature pulsed microchip lasers. We discuss optimization of laser and detector parameters for our application. We then present Raman spectra of particularly challenging planetary analog samples to demonstrate the unique capabilities of this time-resolved Raman instrument, for example, Mars-analog clays and Titan-analog organics. The research described here was carried out at the Jet Propulsion Laboratory, California Institute of Technology, under a contract with the National Aeronautics and Space Administration (NASA).
Raman spectroscopic studies on bacteria
NASA Astrophysics Data System (ADS)
Maquelin, Kees; Choo-Smith, Lin-P'ing; Endtz, Hubert P.; Bruining, Hajo A.; Puppels, Gerwin J.
2000-11-01
Routine clinical microbiological identification of pathogenic micro-organisms is largely based on nutritional and biochemical tests. Laboratory results can be presented to a clinician after 2 - 3 days for most clinically relevant micro- organisms. Most of this time is required to obtain pure cultures and enough biomass for the tests to be performed. In the case of severely ill patients, this unavoidable time delay associated with such identification procedures can be fatal. A novel identification method based on confocal Raman microspectroscopy will be presented. With this method it is possible to obtain Raman spectra directly from microbial microcolonies on the solid culture medium, which have developed after only 6 hours of culturing for most commonly encountered organisms. Not only does this technique enable rapid (same day) identifications, but also preserves the sample allowing it to be double-checked with traditional tests. This, combined with the speed and minimal sample handling indicate that confocal Raman microspectroscopy has much potential as a powerful new tool in clinical diagnostic microbiology.
Synthesis and characterization of porous CaCO3 micro/nano-particles
NASA Astrophysics Data System (ADS)
Achour, A.; Arman, A.; Islam, M.; Zavarian, A. A.; Basim Al-Zubaidi, A.; Szade, J.
2017-06-01
Porous CaCO3 particles, both micro and nano sized, were synthesized in a mixture of Ca(OH)2, hyaluronic acid (HA), glycine, NaOH and NaCl solution with supercritical carbon dioxide. The particles were characterized using X-Ray Diffraction (XRD), Fourier Transform Infrared (FTIR) spectroscope, Raman spectroscope (RS), X-ray photoelectron spectroscope (XPS) and scanning electron microscope techniques. All these techniques showed that the particles crystallize into only one CaCO3 structure, namely the vaterite phase. In addition, FTIR, RS and XPS indicated the presence of residual reactive species i.e. glycine, NaCl, and HA. The XRD results confirmed the presence of NaCl and γ-glycine, which is a crystalline material. Moreover, the HA seems to be mostly embedded in the bulk of the micro-particles. Such materials are promising for biomedical applications such as drug delivery.
NASA Astrophysics Data System (ADS)
Zakharov, V. P.; Bratchenko, I. A.; Artemyev, D. N.; Myakinin, O. O.; Khristoforova, Y. A.; Kozlov, S. V.; Moryatov, A. A.
2015-07-01
The combined application of Raman and autofluorescence spectroscopy in visible and near infrared regions for the analysis of malignant neoplasms of human skin was demonstrated. Ex vivo experiments were performed for 130 skin tissue samples: 28 malignant melanomas, 19 basal cell carcinomas, 15 benign tumors, 9 nevi and 59 normal tissues. Proposed method of Raman spectra analysis allows for malignant melanoma differentiating from other skin tissues with accuracy of 84% (sensitivity of 97%, specificity of 72%). Autofluorescence analysis in near infrared and visible regions helped us to increase the diagnostic accuracy by 5-10%. Registration of autofluorescence in near infrared region is realized in one optical unit with Raman spectroscopy. Thus, the proposed method of combined skin tissues study makes possible simultaneous large skin area study with autofluorescence spectra analysis and precise neoplasm type determination with Raman spectroscopy.
Hancewicz, Thomas M; Xiao, Chunhong; Zhang, Shuliang; Misra, Manoj
2013-12-01
In vivo confocal Raman spectroscopy has become the measurement technique of choice for skin health and skin care related communities as a way of measuring functional chemistry aspects of skin that are key indicators for care and treatment of various skin conditions. Chief among these techniques are stratum corneum water content, a critical health indicator for severe skin condition related to dryness, and natural moisturizing factor components that are associated with skin protection and barrier health. In addition, in vivo Raman spectroscopy has proven to be a rapid and effective method for quantifying component penetration in skin for topically applied skin care formulations. The benefit of such a capability is that noninvasive analytical chemistry can be performed in vivo in a clinical setting, significantly simplifying studies aimed at evaluating product performance. This presumes, however, that the data and analysis methods used are compatible and appropriate for the intended purpose. The standard analysis method used by most researchers for in vivo Raman data is ordinary least squares (OLS) regression. The focus of work described in this paper is the applicability of OLS for in vivo Raman analysis with particular attention given to use for non-ideal data that often violate the inherent limitations and deficiencies associated with proper application of OLS. We then describe a newly developed in vivo Raman spectroscopic analysis methodology called multivariate curve resolution-augmented ordinary least squares (MCR-OLS), a relatively simple route to addressing many of the issues with OLS. The method is compared with the standard OLS method using the same in vivo Raman data set and using both qualitative and quantitative comparisons based on model fit error, adherence to known data constraints, and performance against calibration samples. A clear improvement is shown in each comparison for MCR-OLS over standard OLS, thus supporting the premise that the MCR-OLS method is better suited for general-purpose multicomponent analysis of in vivo Raman spectral data. This suggests that the methodology is more readily adaptable to a wide range of component systems and is thus more generally applicable than standard OLS.
NASA Astrophysics Data System (ADS)
Belalia, M.; Mitov, M.; Bourgerette, C.; Krallafa, A.; Belhakem, M.; Bormann, D.
2006-11-01
Cholesteric liquid crystals (CLC) selectively reflect light when the helical pitch is of the order of the wavelength of the incident beam propagating along the helix axis. The wavelength bandwidth, related to the optical anisotropy, is typically limited to a few tens of nanometers in the visible part of the spectrum, which is insufficient for applications such as white-or-black polarizer-free reflective displays and smart windows for the control of the solar light and heat. A way to make cholesteric films reflecting in a broad wavelength band consists in associating various cholesteric pitches in the same film. In this work, it is shown how a study by confocal micro Raman spectrometry mapping makes it possible to have access to information accounting for the local organization of CLCs in the case of graded pitch materials. These investigations will be correlated to the optical response and the transverse microstructure of the CLC material as investigated by transmission electron microscopy. An accurate analysis of the vibrational behavior evolution of the CO can be correlated to the evolution of the populations of the chiral and achiral groups in the case of the interdiffusion of two CLC substances with various stoechiometries. Besides an easy measurement of the Raman spectrum gives the opportunity to quantify the relative ratio of the mesogenic species and thus to go up by a simple way to the pitch of the helical structure.
In-vivo spinal nerve sensing in MISS using Raman spectroscopy
NASA Astrophysics Data System (ADS)
Chen, Hao; Xu, Weiliang; Broderick, Neil
2016-04-01
In modern Minimally Invasive Spine Surgery (MISS), lack of visualization and haptic feedback information are the main obstacles. The spinal cord is a part of the central nervous system (CNS). It is a continuation of the brain stem, carries motor and sensory messages between CNS and the rest of body, and mediates numerous spinal reflexes. Spinal cord and spinal nerves are of great importance but vulnerable, once injured it may result in severe consequences to patients, e.g. paralysis. Raman Spectroscopy has been proved to be an effective and powerful tool in biological and biomedical applications as it works in a rapid, non-invasive and label-free way. It can provide molecular vibrational features of tissue samples and reflect content and proportion of protein, nucleic acids lipids etc. Due to the distinct chemical compositions spinal nerves have, we proposed that spinal nerves can be identified from other types of tissues by using Raman spectroscopy. Ex vivo experiments were first done on samples taken from swine backbones. Comparative spectral data of swine spinal cord, spinal nerves and adjacent tissues (i.e. membrane layer of the spinal cord, muscle, bone and fatty tissue) are obtained by a Raman micro-spectroscopic system and the peak assignment is done. Then the average spectra of all categories of samples are averaged and normalized to the same scale to see the difference against each other. The results verified the feasibility of spinal cord and spinal nerves identification by using Raman spectroscopy. Besides, a fiber-optic Raman sensing system including a miniature Raman sensor for future study is also introduced. This Raman sensor can be embedded into surgical tools for MISS.
Fabrication of Gold-Coated Ultra-Thin Anodic Porous Alumina Substrates for Augmented SERS
Toccafondi, Chiara; Proietti Zaccaria, Remo; Dante, Silvia; Salerno, Marco
2016-01-01
Anodic porous alumina (APA) is a nanostructured material used as a template in several nanotechnological applications. We propose the use of APA in ultra-thin form (<100 nm) for augmented surface-enhanced Raman scattering (SERS). Here, the effect of in-depth thinning of the APA nanostructures for possible maximization of SERS was addressed. Anodization was carried out on ultra-thin films of aluminum on glass and/or silicon, followed by pore-opening. Gold (Au) was overcoated and micro-Raman/SERS measurements were carried out on test target analytes. Finite integration technique simulations of the APA-Au substrate were used both for the experimental design and simulations. It was observed that, under optimized conditions of APA and Au thickness, the SERS enhancement is higher than on standard APA-Au substrates based on thin (~100 nm) APA by up to a factor of ~20 for test molecules of mercaptobenzoic acid. The agreement between model and experimental results confirms the current understanding of SERS as being mainly due to the physical origin of plasmon resonances. The reported results represent one step towards micro-technological, integrated, disposable, high-sensitivity SERS chemical sensors and biosensors based on similar substrates. PMID:28773525
Structure-Dependent Spectroscopic Properties of Yb3+-Doped Phosphosilicate Glasses Modified by SiO₂.
Wang, Ling; Zeng, Huidan; Yang, Bin; Ye, Feng; Chen, Jianding; Chen, Guorong; Smith, Andew T; Sun, Luyi
2017-02-28
Yb 3+ -doped phosphate glasses containing different amounts of SiO₂ were successfully synthesized by the conventional melt-quenching method. The influence mechanism of SiO₂ on the structural and spectroscopic properties was investigated systematically using the micro-Raman technique. It was worth noting that the glass with 26.7 mol % SiO₂ possessed the longest fluorescence lifetime (1.51 ms), the highest gain coefficient (1.10 ms·pm²), the maximum Stark splitting manifold of ²F 7/2 level (781 cm -1 ), and the largest scalar crystal-field N J and Yb 3+ asymmetry degree. Micro-Raman spectra revealed that introducing SiO₂ promoted the formation of P=O linkages, but broke the P=O linkages when the SiO₂ content was greater than 26.7 mol %. Based on the previous 29 Si MAS NMR experimental results, these findings further demonstrated that the formation of [SiO₆] may significantly affect the formation of P=O linkages, and thus influences the spectroscopic properties of the glass. These results indicate that phosphosilicate glasses may have potential applications as a Yb 3+ -doped gain medium for solid-state lasers and optical fiber amplifiers.
Structure-Dependent Spectroscopic Properties of Yb3+-Doped Phosphosilicate Glasses Modified by SiO2
Wang, Ling; Zeng, Huidan; Yang, Bin; Ye, Feng; Chen, Jianding; Chen, Guorong; Smith, Andew T.; Sun, Luyi
2017-01-01
Yb3+-doped phosphate glasses containing different amounts of SiO2 were successfully synthesized by the conventional melt-quenching method. The influence mechanism of SiO2 on the structural and spectroscopic properties was investigated systematically using the micro-Raman technique. It was worth noting that the glass with 26.7 mol % SiO2 possessed the longest fluorescence lifetime (1.51 ms), the highest gain coefficient (1.10 ms·pm2), the maximum Stark splitting manifold of 2F7/2 level (781 cm−1), and the largest scalar crystal-field NJ and Yb3+ asymmetry degree. Micro-Raman spectra revealed that introducing SiO2 promoted the formation of P=O linkages, but broke the P=O linkages when the SiO2 content was greater than 26.7 mol %. Based on the previous 29Si MAS NMR experimental results, these findings further demonstrated that the formation of [SiO6] may significantly affect the formation of P=O linkages, and thus influences the spectroscopic properties of the glass. These results indicate that phosphosilicate glasses may have potential applications as a Yb3+-doped gain medium for solid-state lasers and optical fiber amplifiers. PMID:28772601
FT Raman microscopy of untreated natural plant fibres
NASA Astrophysics Data System (ADS)
Edwards, H. G. M.; Farwell, D. W.; Webster, D.
1997-11-01
The application of FT-Raman microscopy to the non-destructive analysis of natural plant fibres is demonstrated with samples of flax, jute, ramie, cotton, kapok, sisal and coconut fibre. Vibrational assignments are proposed and characteristic features of each material are presented. Samples were not pre-treated chemically before analysis and were used directly from their respective storage collection; the adaptation of the Raman microscopic technique to the identification of specimens of natural fibres in archaeological burial sites is explored for its forensic potential.
Giant magneto-optical Raman effect in a layered transition metal compound
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ji, Jianting; Zhang, Anmin; Fan, Jiahe
2016-02-16
Here, we report a dramatic change in the intensity of a Raman mode with applied magnetic field, displaying a gigantic magneto-optical effect. Using the nonmagnetic layered material MoS 2 as a prototype system, we demonstrate that the application of a magnetic field perpendicular to the layers produces a dramatic change in intensity for the out-of-plane vibrations of S atoms, but no change for the in-plane breathing mode. The distinct intensity variation between these two modes results from the effect of field-induced broken symmetry on Raman scattering cross-section. A quantitative analysis on the field-dependent integrated Raman intensity provides a unique methodmore » to precisely determine optical mobility. Our analysis is symmetry-based and material-independent, and thus the observations should be general and inspire a new branch of inelastic light scattering and magneto-optical applications.« less
Bacterial identification in real samples by means of micro-Raman spectroscopy
NASA Astrophysics Data System (ADS)
Rösch, Petra; Stöckel, Stephan; Meisel, Susann; Bossecker, Anja; Münchberg, Ute; Kloss, Sandra; Schumacher, Wilm; Popp, Jürgen
2011-07-01
Pathogen detection is essential without time delay especially for severe diseases like sepsis. Here, the survival rate is dependent on a prompt antibiosis. For sepsis three hours after the onset of shock the survival rate of the patient drops below 60 %. Unfortunately, the results from standard diagnosis methods like PCR or microbiology can normally be received after 12 or 36 h, respectively. Therefore diagnosis methods which require less cultivation or even no cultivation at all have to be established for medical diagnosis. Here, Raman spectroscopy, as a vibrational spectroscopic method, is a very sensitive and selective approach and monitors the biochemical composition of the investigated sample. Applying micro-Raman spectroscopy allows for a spatial resolution below 1 μm and is therefore in the size range of bacteria. Raman spectra of bacteria depend on the physiological status. Therefore, the databases require the inclusion of the necessary environmental parameters such as temperature, pH, nutrition, etc. Such large databases therefore require a specialized chemometric approach, since the variation between different strains is small. In this contribution we will demonstrate the capability of Raman spectroscopy to identify pathogens without cultivation even from real environmental or medical samples.
NASA Astrophysics Data System (ADS)
Khmaladze, Alexander; Ganguly, Arindam; Raghavan, Mekhala; Kuo, Shiuhyang; Cole, Jacqueline H.; Marcelo, Cynthia L.; Feinberg, Stephen E.; Izumi, Kenji; Morris, Michael D.
2012-01-01
We show the application of near-infrared Raman Spectroscopy to in-vitro monitoring of the viability of tissue constructs (EVPOMEs). During their two week production period EVPOME may encounter thermal, chemical or biochemical stresses that could cause development to cease, rendering the affected constructs useless. We discuss the development of a Raman spectroscopic technique to study EVPOMEs noninvasively, with the ultimate goal of applying it in-vivo. We identify Raman spectroscopic failure indicators for EVPOMEs, which are stressed by temperature, and discuss the implications of varying calcium concentration and pre-treatment of the human keratinocytes with Rapamycin. In particular, Raman spectra show correlation of the peak height ratios of CH2 deformation to phenylalanine ring breathing, providing a Raman metric to distinguish between viable and nonviable constructs. We also show the results of singular value decomposition analysis, demonstrating the applicability of Raman spectroscopic technique to both distinguish between stressed and non-stressed EVPOME constructs, as well as between EVPOMEs and bare AlloDerm® substrates, on which the oral keratinocytes have been cultured. We also discuss complications arising from non-uniform thickness of the AlloDerm® substrate and the cultured constructs, as well as sampling protocols used to detect local stress and other problems that may be encountered in the constructs.
NASA Astrophysics Data System (ADS)
Windom, Bret C.
Friction and wear have undisputedly huge macroscopic effects on the cost and lifetime of many mechanical systems. The cost to replace parts and the cost to overcome the energy losses associated with friction, although small in nature, can be enormous over long operating times. The understanding of wear and friction begins with the understanding of the physics and chemistry between the reacting surfaces on a microscopic level. Light as a diagnostic tool is a good candidate to perform the very sensitive microscopic measurements needed to help understand the fundamental science occurring in friction/wear systems. Light's small length scales provide the capabilities to characterize very local surface phenomena, including thin transfer films and surface chemical transitions. Light-based diagnostic techniques provide nearly instantaneous results, enabling one to make in situ/real time measurements which could be used to track wear events and associated chemical kinetics. In the present study, two optical diagnostic techniques were investigated for the analysis of tribological systems. The first technique employed was Raman spectroscopy. Raman spectroscopy was investigated as a possible means for in situ measurement of thin transfer films in order to track the wear kinetics and structural transitions of bulk polymers. A micro-Raman system was designed, built, and characterized to track fresh wear films created from a pin-on-disk tribometer. The system proved capable of characterizing and tracking wear film thicknesses of ˜2 mum and greater. In addition, the system provided results indicating structural changes in the wear film as compared to the bulk when sliding speeds were increased. The spectral changes due to the altering of molecular vibrations can be attributed to the increase in temperature during high sliding speeds. Raman spectroscopy was also used to characterize the oxidation of molybdenum disulphide, a solid lubricant used in many applications, including high vacuum sliding. Resonance Raman effects were observed when an excitation wavelength of 632.8 nm was used. Raman spectroscopy was carried out on amorphous MoS2 while its temperature was increased to track the thermally induced oxidation of the MoS2 surface. In addition, other forms of MoS2 were investigated through Raman spectroscopy in which key distinctions between spectra were made. The second technique employed was atomic emission spectroscopy (AES) used to measure constituent species present in arcs created during electrical sliding contacts. Spectra indicated the presence of copper and zinc in the arcs created between copper fiber bundled brushes and a copper rotor. Atomic emission was used to measure the arc duration with a photo-multiplier tube (PMT) while the collected spectra were processed to assess arc temperature. The results suggest arcing in high-current electrical sliding contacts may be at least partially responsible for the high asymmetrical wear measured during tribology tests.
Muhammed Shameem, K M; Chawla, Arun; Mallya, Madhukar; Barik, Bijay Kumar; Unnikrishnan, V K; Kartha, V B; Santhosh, C
2018-06-01
Presence of renal-calculi (kidney stones) in human urethra is being increasingly diagnosed over the last decade and is considered as one of the most painful urological disorders. Accurate analysis of such stones plays a vital role in the evaluation of urolithiasis patients and in turn helps the clinicians toward exact etiologies. Two highly complementary laser-based analytical techniques; laser-induced breakdown spectroscopy (LIBS) and micro-Raman spectroscopy have been used to identify the chemical composition of different types of renal-calculi. LIBS explores elemental characteristics while Raman spectroscopy provides molecular details of the sample. This complete information on the sample composition might help clinicians to identify the key aspects of the formation of kidney stones, hence assist in therapeutic management and to prevent recurrence. The complementarity of both techniques has been emphasized and discussed. LIBS spectra of different types of stones suggest the probable composition of it by virtue of the major, minor and trace elements detected from the sample. However, it failed to differentiate the crystalline form of different hydrates of calcium oxalate stone. This lacuna was overcome by the use of Raman spectroscopy and these results are compared with conventional chemical analysis. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
A system for the rapid detection of bacterial contamination in cell-based therapeutica
NASA Astrophysics Data System (ADS)
Bolwien, Carsten; Erhardt, Christian; Sulz, Gerd; Thielecke, Hagen; Johann, Robert; Pudlas, Marieke; Mertsching, Heike; Koch, Steffen
2010-02-01
Monitoring the sterility of cell or tissue cultures is of major concern, particularly in the fields of regenerative medicine and tissue engineering when implanting cells into the human body. Our sterility-control system is based on a Raman micro-spectrometer and is able to perform fast sterility testing on microliters of liquid samples. In conventional sterility control, samples are incubated for weeks to proliferate the contaminants to concentrations above the detection limit of conventional analysis. By contrast, our system filters particles from the liquid sample. The filter chip fabricated in microsystem technology comprises a silicon nitride membrane with millions of sub-micrometer holes to retain particles of critical sizes and is embedded in a microfluidic cell specially suited for concomitant microscopic observation. After filtration, identification is carried out on the single particle level: image processing detects possible contaminants and prepares them for Raman spectroscopic analysis. A custom-built Raman-spectrometer-attachment coupled to the commercial microscope uses 532nm or 785nm Raman excitation and records spectra up to 3400cm-1. In the final step, the recorded spectrum of a single particle is compared to an extensive library of GMP-relevant organisms, and classification is carried out based on a support vector machine.
Material for surface-enhanced Raman spectroscopy, and SER sensors and method for preparing same
NASA Technical Reports Server (NTRS)
Farquharson, Stuart (Inventor); Nelson, Chad (Inventor); Lee, Yuan-Hsiang (Inventor)
2003-01-01
Metal-doped sol-gel materials, suitable for use as sensors for surface-enhanced Raman spectroscopic analysis for trace chemical detection, are produced by effecting gelation and solvent removal of a doped sol-gel under mild temperature conditions. At least in certain instances reaction and drying will desirably be effected in an oxygen-starved environment. The metal of the sol-gel material functions, when irradiated, to produce a plasmon field for interaction with molecules of an analyte in contact therewith, increasing by orders of magnitude Raman photons that are generate by excitation radiation, and the method allows matching of the metal and metal particle size to a wavelength of light (or incident radiation, e.g., laser radiation) to generate surface plasmons. The porosity of the sol-gel material dramatically increases the surface area, and thereby the amount of metal exposed for analyte interaction. The sensors provided may be in the form of glass vials, fiber optics, multi-well micro-sample plates, etc., having surface coatings of the doped sol-gel material, to provide sampling systems for use in a Raman instrument.
Dubina, E; Korat, L; Black, L; Strupi-Šuput, J; Plank, J
2013-07-01
Micro-Raman spectroscopy has been used to follow the reaction of free lime (CaO) exposed for 24h to moist air at 80 °C under conditions of different relative humidities (10-80% RH). X-ray diffraction and SEM imaging were applied as complementary techniques. The conversion of lime to calcium hydroxide and its subsequent carbonation to various calcium carbonate polymorphs was found to strongly depend on the relative humidity. At low RH (10-20%), only Raman spectroscopy revealed the formation of early amorphous CaCO3 which in the XRD patterns was detected only at ≥40% RH. However, XRD analysis could identify the crystalline polymorphs formed at higher relative humidities. Thus, between 20 and 60% RH, all three CaCO3 polymorphs (calcite, aragonite and vaterite) were observed via XRD whereas at high relative humidity (80%), calcite was the predominant reaction product. The results demonstrate the usefulness of Raman spectroscopy in the study of minor cement constituents and their reaction products on air, especially of amorphous character. Copyright © 2013 Elsevier B.V. All rights reserved.
Raman spectroscopy of bio fluids: an exploratory study for oral cancer detection
NASA Astrophysics Data System (ADS)
Brindha, Elumalai; Rajasekaran, Ramu; Aruna, Prakasarao; Koteeswaran, Dornadula; Ganesan, Singaravelu
2016-03-01
ion for various disease diagnosis including cancers. Oral cancer is one of the most common cancers in India and it accounts for one third of the global oral cancer burden. Raman spectroscopy of tissues has gained much attention in the diagnostic oncology, as it provides unique spectral signature corresponding to metabolic alterations under different pathological conditions and micro-environment. Based on these, several studies have been reported on the use of Raman spectroscopy in the discrimination of diseased conditions from their normal counterpart at cellular and tissue level but only limited studies were available on bio-fluids. Recently, optical characterization of bio-fluids has also geared up for biomarker identification in the disease diagnosis. In this context, an attempt was made to study the metabolic variations in the blood, urine and saliva of oral cancer patients and normal subjects using Raman spectroscopy. Principal Component based Linear Discriminant Analysis (PC-LDA) followed by Leave-One-Out Cross-Validation (LOOCV) was employed to find the statistical significance of the present technique in discriminating the malignant conditions from normal subjects.
NASA Astrophysics Data System (ADS)
Dobner, Sven; Fallnich, Carsten
2014-02-01
We present the hyperspectral imaging capabilities of in-line interferometric femtosecond stimulated Raman scattering. The beneficial features of this method, namely, the improved signal-to-background ratio compared to other applicable broadband stimulated Raman scattering methods and the simple experimental implementation, allow for a rather fast acquisition of three-dimensional raster-scanned hyperspectral data-sets, which is shown for PMMA beads and a lipid droplet in water as a demonstration. A subsequent application of a principle component analysis displays the chemical selectivity of the method.
Paret, Mathews L; Sharma, Shiv K; Green, Lisa M; Alvarez, Anne M
2010-04-01
Raman spectra of Gram-positive and Gram-negative plant bacteria have been measured with micro-Raman spectrometers equipped with 785 and 514.5 nm lasers. The Gram-positive bacteria Microbacterium testaceum, Paenibacillus validus, and Clavibacter michiganensis subsp. michiganensis have strong carotenoid bands in the regions 1155-1157 cm(-1) and 1516-1522 cm(-1) that differentiate them from other tested Gram-negative bacteria. In the Raman spectrum of Gram-positive bacteria Bacillus megaterium excited with 785 nm laser, the Raman bands at 1157 and 1521 cm(-1) are weak in intensity compared to other Gram-positive bacteria, and these bands did not show significant resonance Raman enhancement in the spectrum recorded with 514.5 nm laser excitation. The Gram-positive bacteria could be separated from each other based on the bands associated with the in-phase C=C (v(1)) vibrations of the polyene chain of carotenoids. None of the Gram-negative bacteria tested had carotenoid bands. The bacteria in the genus Xanthomonas have a carotenoid-like pigment, xanthomonadin, identified in Xanthomonas axonopodis pv. dieffenbachiae, and it is a unique Raman marker for the bacteria. The representative bands for xanthomonadin were the C-C stretching (v(2)) vibrations of the polyene chain at 1135-1136 cm(-1) and the in-phase C=C (v(1)) vibrations of the polyene chain at 1529-1531 cm(-1), which were distinct from the carotenoid bands of other tested bacteria. The tyrosine peak in the region 1170-1175 cm(-1) was the only other marker present in Gram-negative bacteria that was absent in all tested Gram-positives. A strong-intensity exopolysaccharide-associated marker at 1551 cm(-1) is a distinguishable feature of Enterobacter cloacae. The Gram-negative Agrobacterium rhizogenes and Ralstonia solanacearum were differentiated from each other and other tested bacteria on the basis of presence or absence and relative intensities of peaks. The principal components analysis (PCA) of the spectra excited with 785 nm laser differentiated the various strains of bacteria based on the unique pigments these bacteria do or do not possess. Raman spectroscopy of diverse plant bacteria that are pathogenic and non-pathogenic to plants, and isolated from plants and soil, indicates the possibilities of using the method in understanding plant-bacterial interactions at the cellular level.
Raman Spectroscopy: An Emerging Tool in Neurodegenerative Disease Research and Diagnosis.
Devitt, George; Howard, Kelly; Mudher, Amrit; Mahajan, Sumeet
2018-03-21
The pathogenesis underlining many neurodegenerative diseases remains incompletely understood. The lack of effective biomarkers and disease preventative medicine demands the development of new techniques to efficiently probe the mechanisms of disease and to detect early biomarkers predictive of disease onset. Raman spectroscopy is an established technique that allows the label-free fingerprinting and imaging of molecules based on their chemical constitution and structure. While analysis of isolated biological molecules has been widespread in the chemical community, applications of Raman spectroscopy to study clinically relevant biological species, disease pathogenesis, and diagnosis have been rapidly increasing since the past decade. The growing number of biomedical applications has shown the potential of Raman spectroscopy for detection of novel biomarkers that could enable the rapid and accurate screening of disease susceptibility and onset. Here we provide an overview of Raman spectroscopy and related techniques and their application to neurodegenerative diseases. We further discuss their potential utility in research, biomarker detection, and diagnosis. Challenges to routine use of Raman spectroscopy in the context of neuroscience research are also presented.
Raman Gas Species Measurements in Hydrocarbon-Fueled Rocket Engine Injector Flows
NASA Technical Reports Server (NTRS)
Wehrmeyer, Joseph; Hartfield, Roy J., Jr.; Trinh, Huu P.; Dobson, Chris C.; Eskridge, Richard H.
2000-01-01
Rocket engine propellent injector development at NASA-Marshall includes experimental analysis using optical techniques, such as Raman, fluorescence, or Mie scattering. For the application of spontaneous Raman scattering to hydrocarbon-fueled flows a technique needs to be developed to remove the interfering polycyclic aromatic hydrocarbon fluorescence from the relatively weak Raman signals. A current application of such a technique is to the analysis of the mixing and combustion performance of multijet, impinging-jet candidate fuel injectors for the baseline Mars ascent engine, which will burn methane and liquid oxygen produced in-situ on Mars to reduce the propellent mass transported to Mars for future manned Mars missions. The Raman technique takes advantage of the strongly polarized nature of Raman scattering. It is shown to be discernable from unpolarized fluorescence interference by subtracting one polarized image from another. Both of these polarized images are obtained from a single laser pulse by using a polarization-separating calcite rhomb mounted in the imaging spectrograph. A demonstration in a propane-air flame is presented, as well as a high pressure demonstration in the NASA-Marshall Modular Combustion Test Artice, using the liquid methane-liquid oxygen propellant system
NASA Astrophysics Data System (ADS)
Sibi, N.; Subodh, G.
2017-12-01
Garnets are naturally occurring minerals with the general formula X3Y2Z3O12 having various applications. In the present study, the structural and physical properties of a garnet mineral obtained from Indian Rare Earth Ltd., Manavalakurichi, Tamil Nadu, India were comprehensively investigated. The compositional analysis using electron probe micro analysis (EPMA) revealed that the mineral belongs to almandine-pyrope solid solution (Al70Py29) with the chemical formula (Fe1.72Mg0.8Mn0.01Ca0.02) (Fe0.04Al2.36) Si2.93O12. Rietveld refinement of the x-ray diffraction pattern confirms that the space group is Ia{ - }\\overline{3} d with refined cubic lattice parameter a = 11.550(4) Å. The refined occupancy values of multiple cations in the dodecahedral and octahedral sites are in agreement with the EPMA data. Fourier transform infrared and FT Raman spectra show bands corresponding to almandine-pyrope solid solution. Peak splitting of IR and Raman bands confirms presence of multiple cations in the dodecahedral site. Thermogravimetric/differential thermal analysis shows that the mineral is stable up to 600°C in spite of the presence of Fe2+ ions. Low temperature magnetic susceptibility data is in agreement with the amount of Fe2+ ions present in the mineral. The dielectric constant of the mineral varied from 6 to 16.5 when sintered at temperatures ranging from 600°C to 1250°C.
Raman acoustic levitation spectroscopy of red blood cells and Plasmodium falciparum trophozoites.
Puskar, Ljiljana; Tuckermann, Rudolf; Frosch, Torsten; Popp, Jürgen; Ly, Vanalysa; McNaughton, Don; Wood, Bayden R
2007-09-01
Methods to probe the molecular structure of living cells are of paramount importance in understanding drug interactions and environmental influences in these complex dynamical systems. The coupling of an acoustic levitation device with a micro-Raman spectrometer provides a direct molecular probe of cellular chemistry in a containerless environment minimizing signal attenuation and eliminating the affects of adhesion to walls and interfaces. We show that the Raman acoustic levitation spectroscopic (RALS) approach can be used to monitor the heme dynamics of a levitated 5 microL suspension of red blood cells and to detect hemozoin in malaria infected cells. The spectra obtained have an excellent signal-to-noise ratio and demonstrate for the first time the utility of the technique as a diagnostic and monitoring tool for minute sample volumes of living animal cells.
NASA Astrophysics Data System (ADS)
Yang, Chun-Chen; Chiu, Shwu-Jer; Lin, Che-Tseng
A novel composite polymer membrane based on poly(vinyl alcohol)/hydroxyapatite (PVA/HAP) was successfully prepared by a solution casting method. The characteristic properties of the PVA/HAP composite polymer membranes were examined by thermal gravimetric analysis (TGA), X-ray diffraction (XRD), scanning electron microscopy (SEM), micro-Raman spectroscopy and AC impedance method. An air-breathing DMFC, comprised of an air cathode electrode with MnO 2/BP2000 carbon inks on Ni-foam, an anode electrode with PtRu black on Ti-mesh, and the PVA/HAP composite polymer membrane, was assembled and studied. It was found that this alkaline DMFC showed an improved electrochemical performance at ambient temperature and pressure; the maximum peak power density of an air-breathing DMFC in 8 M KOH + 2 M CH 3OH solution is about 11.48 mW cm -2. From the application point of view, these composite polymer membranes show a high potential for the DMFC applications.
NASA Astrophysics Data System (ADS)
Chafer, M.; Lekiefs, Q.; Gorse, A.; Beaudou, B.; Debord, B.; Gérôme, F.; Benabid, F.
2017-02-01
Raman-gas filled HC-PCF has proved to be an outstanding Raman-convertor, as illustrated by the generation of more than 5 octaves wide Raman comb using a hydrogen-filled Kagome HC-PCF pumped with high power picosecond-laser, or the generation of multiline Raman-source in the UV-Vis using a very compact system pumped with micro-chip laser. Whilst these demonstrations are promising, a principal challenge for the industrialization of such a Raman source is its lifetime as the H2 diffusion through silica is high enough to leak out from the fiber within only a few months. Here, we report on a HC-PCF based Raman multiline source with a very long life-span. The system consists of hydrogen filled ultra-low loss HC-PCF contained in highly sealed box, coined CombBox, and pumped with a 532 nm micro-chip laser. This combination is a turnkey multiline Raman-source with a "shoe box" size. The CombBox is a robust and compact component that can be integrated and pumped with any common pulsed laser. When pumped with a 32 mW average power and 1 ns frequency-doubled Nd:Yag microchip laser, this Raman-source generates 24 lines spanning from 355 to 745 nm, and a peak power density per line of 260 mW/nm for the strongest lines. Both the output power and the spectrum remained constant over its monitoring duration of more than six months. The spectrum of this multiline laser superimposes with no less than 17 absorption peaks of fluorescent dyes from the Alexa Fluor family used as biological markers.
NASA Astrophysics Data System (ADS)
Banerjee, Amrita; Perez-Castillejos, R.; Hahn, D.; Smirnov, Alex I.; Grebel, H.
2010-04-01
We used surface-enhanced Raman spectroscopy (SERS) to detect binding events between streptavidin and biotinylated lipid bilayers. The binding events took place at the surface between micro-fluidic channels and anodized aluminum oxide (AAO) with the latter serving as substrates. The bilayers were incorporated in the substrate pores. It was revealed that non-bound molecules were easily washed away and that large suspended cells ( Salmonella enterica) are less likely to interfere with the monitoring process: when focusing to the lower surface of the channel, one may resolve mostly the bound molecules.
Micro and nanocrystalline diamond formation on reticulated vitreous carbon substrate
NASA Astrophysics Data System (ADS)
Diniz, A. V.; Trava-Airoldi, V. J.; Corat, E. J.; Ferreira, N. G.
2005-10-01
High diamond nucleation and a three-dimensional growth on reticulated vitreous carbon substrate are obtained by chemical vapor deposition. Scanning electron microscopy images show continuous films covering the whole substrate including the center of 3.5 mm thick porous samples. It is evident the nanocrystalline diamond (NCD) film formation on deeper substrate regions. The grain size can vary from nano to micro scale for deposition time of 20 h. Raman spectra of sample regions closer to filaments exhibit well-defined diamond line. For central regions of sample (depth between 1.0 and 2.0 mm) Raman spectra also confirm NCD film.
Fine Structure of the Low-Frequency Raman Phonon Bands of Single-Wall Carbon Nanotubes
NASA Technical Reports Server (NTRS)
Iliev, M. N.; Litvinchuk, A. P.; Arepalli, S.; Nikolaev, P.; Scott, C. D.
1999-01-01
The Raman spectra of singled-wall carbon nanotubes (SWNT) produced by laser and are process were studied between 5 and 500 kappa. The line width vs. temperature dependence of the low-frequency Raman bands between 150 and 200/ cm deviates from that expected for phonon decay through phonon-phonon scattering mechanism. The experimental results and their analysis provided convincing evidence that each of the low-frequency Raman lines is a superposition of several narrower Raman lines corresponding to tubes of nearly the same diameter. The application of Raman spectroscopy to probe the distribution of SWNT by both diameter and chirality is discussed.
Venkatasubbu, G Devanand; Ramasamy, S; Ramakrishnan, V; Kumar, J
2011-12-01
Hydroxyapatite is a bioceramic which has a wide range of medical application for bone diseases. To enhance its usage, we have prepared ciprofloxacin loaded nano hydroxyapatite (HA) composite with a natural polymer, alginate, using wet chemical method at low temperature. The prepared composites were analyzed by various physicochemical methods. The results show that the nano HA crystallites are well intact with the alginate macromolecules. For the composite system FT-IR and micro Raman results are reported in this paper. Studies on the drug loading and drug release have been done. The drug is pre-adsorbed onto the ceramic particle before the formation of composite. The thermal behavior of composite has been studied using thermo gravimetric analysis (TGA). This work, reports that the nanocomposite prepared under optimum condition could prolong the release of ciprofloxacin compared with the ciprofloxacin loaded hydroxyapatite.
Application of silicon zig-zag wall arrays for anodes of Li-ion batteries
NASA Astrophysics Data System (ADS)
Li, G. V.; Rumyantsev, A. M.; Levitskii, V. S.; Beregulin, E. V.; Zhdanov, V. V.; Terukov, E. I.; Astrova, E. V.
2016-01-01
Cyclic tests of anodes based on zigzag wall arrays fabricated by the electrochemical etching and post-anodization treatment of silicon have been performed. Compared with anodes based on nanowires and planar thin films, these structures have several advantages. An ex situ analysis of the morphology and structural transformations in a material subjected to cyclic lithiation was conducted by electron microscopy and micro-Raman spectroscopy. The effect of geometrical parameters and a cycling mode on the degradation rate was studied. It is shown that a significant rise in the cycle life of the anode can be obtained by the restriction of the inserted amount of lithium. The anode, subjected to galvanostatic cycling at a rate C/2.8 at a limited charge capacity of 1000 mA · h g-1, demonstrates no degradation after 1200 cycles.
Application of Raman spectroscopy for on-line monitoring of low dose blend uniformity.
Hausman, Debra S; Cambron, R Thomas; Sakr, Adel
2005-07-14
On-line Raman spectroscopy was used to evaluate the effect of blending time on low dose, 1%, blend uniformity of azimilide dihydrochloride. An 8 qt blender was used for the experiments and instrumented with a Raman probe through the I-bar port. The blender was slowed to 6.75 rpm to better illustrate the blending process (normal speed is 25 rpm). Uniformity was reached after 20 min of blending at 6.75 rpm (135 revolutions or 5.4 min at 25 rpm). On-line Raman analysis of blend uniformity provided more benefits than traditional thief sampling and off-line analysis. On-line Raman spectroscopy enabled generating data rich blend profiles, due to the ability to collect a large number of samples during the blending process (sampling every 20s). In addition, the Raman blend profile was rapidly generated, compared to the lengthy time to complete a blend profile with thief sampling and off-line analysis. The on-line Raman blend uniformity results were also significantly correlated (p-value < 0.05) to the HPLC uniformity results of thief samples.
NASA Astrophysics Data System (ADS)
Paret, Mathews L.; Sharma, Shiv K.; Misra, Anupam K.; Acosta, Tayro; deSilva, Asoka S.; Vowell, Tomie; Alvarez, Anne M.
2012-06-01
We used micro- and resonance Raman spectroscopy with 785 nm and 514.5 nm laser excitation, respectively, to characterize a plant pathogenic bacteria, Xanthomonas axonopodis pv. dieffenbachiae D150. The bacterial genus Xathomonas is closely related to bacterial genus Stenotrophomonas that causes an infection in humans. This study has identified for the first time the unique Raman spectra of the carotenoid-like pigment xanthomonadin of the Xanthomonas strain. Xanthomonadin is a brominated aryl-polyene pigment molecule similar to carotenoids. Further studies were conducted using resonance Raman spectroscopy with 514.5 nm laser excitation on several strains of the bacterial genus Xanthomonas isolated from numerous plants from various geographical locations. The current study revealed that the Raman bands representing the vibrations (v1, v2, v3) of the polyene chain of xanthomonadin are 1003-1005 (v3), 1135-1138 (v2), and 1530 (v1). Overtone bands representing xanthomonadin were identified as 2264-2275 (2v2), and combinational bands at 2653-2662 (v1+ v2). The findings from this study validate our previous finding that the Raman fingerprints of xanthomonadin are unique for the genus Xanthomonas. This facilitates rapid identification (~5 minutes) of Xanthomonas spp. from bacterial culture plates. The xanthomonadin marker is different from Raman markers of many other bacterial genus including Agrobacterium, Bacillus, Clavibacter, Enterobacter, Erwinia, Microbacterium, Paenibacillus, and Ralstonia. This study also identified Xanthomonas spp. from bacterial strains isolated from a diseased wheat sample on a culture plate.
Raman microspectroscopy of nucleus and cytoplasm for human colon cancer diagnosis.
Liu, Wenjing; Wang, Hongbo; Du, Jingjing; Jing, Chuanyong
2017-11-15
Subcellular Raman analysis is a promising clinic tool for cancer diagnosis, but constrained by the difficulty of deciphering subcellular spectra in actual human tissues. We report a label-free subcellular Raman analysis for use in cancer diagnosis that integrates subcellular signature spectra by subtracting cytoplasm from nucleus spectra (Nuc.-Cyt.) with a partial least squares-discriminant analysis (PLS-DA) model. Raman mapping with the classical least-squares (CLS) model allowed direct visualization of the distribution of the cytoplasm and nucleus. The PLS-DA model was employed to evaluate the diagnostic performance of five types of spectral datasets, including non-selective, nucleus, cytoplasm, ratio of nucleus to cytoplasm (Nuc./Cyt.), and nucleus minus cytoplasm (Nuc.-Cyt.), resulting in diagnostic sensitivity of 88.3%, 84.0%, 98.4%, 84.5%, and 98.9%, respectively. Discriminating between normal and cancerous cells of actual human tissues through subcellular Raman markers is feasible, especially when using the nucleus-cytoplasm difference spectra. The subcellular Raman approach had good stability, and had excellent diagnostic performance for rectal as well as colon tissues. The insights gained from this study shed new light on the general applicability of subcellular Raman analysis in clinical trials. Copyright © 2017 Elsevier B.V. All rights reserved.
Surface-Enhanced Raman Spectroscopy of Carbon Nanomembranes from Aromatic Self-Assembled Monolayers.
Zhang, Xianghui; Mainka, Marcel; Paneff, Florian; Hachmeister, Henning; Beyer, André; Gölzhäuser, Armin; Huser, Thomas
2018-02-27
Surface-enhanced Raman scattering spectroscopy (SERS) was employed to investigate the formation of self-assembled monolayers (SAMs) of biphenylthiol, 4'-nitro-1,1'-biphenyl-4-thiol, and p-terphenylthiol on Au surfaces and their structural transformations into carbon nanomembranes (CNMs) induced by electron irradiation. The high sensitivity of SERS allows us to identify two types of Raman scattering in electron-irradiated SAMs: (1) Raman-active sites exhibit similar bands as those of pristine SAMs in the fingerprint spectral region, but with indications of an amorphization process and (2) Raman-inactive sites show almost no Raman-scattering signals, except a very weak and broad D band, indicating a lack of structural order but for the presence of graphitic domains. Statistical analysis showed that the ratio of the number of Raman-active sites to the total number of measurement sites decreases exponentially with increasing the electron irradiation dose. The maximum degree of cross-linking ranged from 97 to 99% for the three SAMs. Proof-of-concept experiments were conducted to demonstrate potential applications of Raman-inactive CNMs as a supporting membrane for Raman analysis.
Surface-enhanced Raman spectroscopy of urine by an ingenious near-infrared Raman spectrometer
NASA Astrophysics Data System (ADS)
Feng, Shangyuan; Chen, Weiwei; Li, Yongzeng; Chen, Guannan; Huang, Zufang; Liao, Xiaohua; Xie, Zhiming; Chen, Rong
2007-11-01
This paper demonstrates the potential of an elaborately devised near-infrared Raman system in analysis of urine. The broad band in the long-wavelength region of the electronic absorption spectra of the sol with added adsorbent at certain concentrations has been explained in terms of the aggregation of the colloidal silver particles. We have reported the surface-enhanced Raman (SERS) spectra of urine, and studied the silver solution enhanced effects on the urine Raman scattering. The Raman bands of human's urine was assigned to certain molecule vibrations. We have found that different donators have dissimilar SERS of urine in different physiological condition. Comparatively few studies have explored the ability of Raman spectroscopy for the analysis of urine acid. In the present report, we investigated the ability of surface enhanced Raman spectroscopy to measure uric acid in the human urine. The results suggested that the present Raman system holds considerable promise for practical use. Practical applications such as the quantitative medical examination of urine metabolites may also be feasible in the near future.
Ion beam analysis in cultural heritage studies: Milestones and perspectives
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dran, Jean-Claude; Calligaro, Thomas
2013-07-18
For three decades, ion beam analysis (IBA) in external mode was considered as the best choice for the characterisation of cultural heritage materials, as it combines excellent analytical performance and non-invasive character. However, in recent years, other analytical techniques arose as serious competitors, such as those based on synchrotron radiation (X-ray absorption, fluorescence or diffraction) or those using portable instruments (XRF, micro-Raman). It is shown that nevertheless IBA remains unmatched thanks to two unique features, namely the analysis of light elements and the high-resolution 3D chemical imaging.
NASA Astrophysics Data System (ADS)
Kalashnyk, N.; Perry, D. L.; Massuyeau, F.; Faulques, E.
2017-12-01
Several optical microprobe experiments of the anhydrous uranium carbonate—rutherfordine—are presented in this work and compared to periodic density functional theory results. Rutherfordine is the simplest uranyl carbonate and constitutes an ideal model system for the study of the rich uranium carbonate family relevant for environmental sustainability. Micro-Raman, micro-reflectance, and micro-photoluminescence (PL) spectroscopy studies have been carried out in situ on native, micrometer-sized crystals. The sensitivity of these techniques is sufficient to analyze minute amounts of samples in natural environments without using x-ray analysis. In addition, very intense micro-PL and micro-reflectance spectra that were not reported before add new results on the ground and excited states of this mineral. The optical gap value determined experimentally is found at about 2.6-2.8 eV. Optimized geometry, band structure, and phonon spectra have been calculated. The main vibrational lines are identified and predicted by this theoretical study. This work is pertinent for optical spectroscopy, for identification of uranyl species in various environmental settings, and for nuclear forensic analysis.
Corvucci, Francesca; Nobili, Lara; Melucci, Dora; Grillenzoni, Francesca-Vittoria
2015-02-15
Honey traceability to food quality is required by consumers and food control institutions. Melissopalynologists traditionally use percentages of nectariferous pollens to discriminate the botanical origin and the entire pollen spectrum (presence/absence, type and quantities and association of some pollen types) to determinate the geographical origin of honeys. To improve melissopalynological routine analysis, principal components analysis (PCA) was used. A remarkable and innovative result was that the most significant pollens for the traditional discrimination of the botanical and geographical origin of honeys were the same as those individuated with the chemometric model. The reliability of assignments of samples to honey classes was estimated through explained variance (85%). This confirms that the chemometric model properly describes the melissopalynological data. With the aim to improve honey discrimination, FT-microRaman spectrography and multivariate analysis were also applied. Well performing PCA models and good agreement with known classes were achieved. Encouraging results were obtained for botanical discrimination. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Naddaf, M.; Al-Mariri, A.; Haj-Mhmoud, N.
2017-06-01
Nanostructured layers composed of silver-porous silicon (Ag-PS) have been formed by an electrochemical etching of p-type (1 1 1) silicon substrate in a AgNO3:HF:C2H5OH solution at different etching times (10 min-30 min). Scanning electron microscopy (SEM) and energy-dispersive x-ray spectroscopy (EDS) results reveal that the produced layers consist of Ag dendrites and a silicon-rich porous structure. The nanostructuring nature of the layer has been confirmed by spatial micro-Raman scattering and x-ray diffraction techniques. The Ag dendrites exhibit a surface-enhanced Raman scattering (SERS) spectrum, while the porous structure shows a typical PS Raman spectrum. Upon increasing the etching time, the average size of silicon nanocrystallite in the PS network decreases, while the average size of Ag nanocrystals is slightly affected. In addition, the immobilization of prokaryote Salmonella typhimurium DNA via physical adsorption onto the Ag-PS layer has been performed to demonstrate its efficiency as a platform for detection of biological molecules using SERS.
NASA Astrophysics Data System (ADS)
Tiwari, Vidhu S.; Khetani, Altaf; Monfared, Ali Momenpour T.; Smith, Brett; Anis, Hanan; Trudeau, Vance L.
2012-03-01
The present work explores the feasibility of using surface enhanced Raman scattering (SERS) for detecting the neurotransmitters such as glutamate (GLU) and gamma-amino butyric acid (GABA). These amino acid neurotransmitters that respectively mediate fast excitatory and inhibitory neurotransmission in the brain, are important for neuroendocrine control, and upsets in their synthesis are also linked to epilepsy. Our SERS-based detection scheme enabled the detection of low amounts of GLU (10-7 M) and GABA (10-4 M). It may complement existing techniques for characterizing such kinds of neurotransmitters that include high-performance liquid chromatography (HPLC) or mass spectrography (MS). This is mainly because SERS has other advantages such as ease of sample preparation, molecular specificity and sensitivity, thus making it potentially applicable to characterization of experimental brain extracts or clinical diagnostic samples of cerebrospinal fluid and saliva. Using hollow core photonic crystal fiber (HC-PCF) further enhanced the Raman signal relative to that in a standard cuvette providing sensitive detection of GLU and GABA in micro-litre volume of aqueous solutions.
A nanoporous gold membrane for sensing applications
Oo, Swe Zin; Silva, Gloria; Carpignano, Francesca; Noual, Adnane; Pechstedt, Katrin; Mateos, Luis; Grant-Jacob, James A.; Brocklesby, Bill; Horak, Peter; Charlton, Martin; Boden, Stuart A.; Melvin, Tracy
2016-01-01
Design and fabrication of three-dimensionally structured, gold membranes containing hexagonally close-packed microcavities with nanopores in the base, are described. Our aim is to create a nanoporous structure with localized enhancement of the fluorescence or Raman scattering at, and in the nanopore when excited with light of approximately 600 nm, with a view to provide sensitive detection of biomolecules. A range of geometries of the nanopore integrated into hexagonally close-packed assemblies of gold micro-cavities was first evaluated theoretically. The optimal size and shape of the nanopore in a single microcavity were then considered to provide the highest localized plasmon enhancement (of fluorescence or Raman scattering) at the very center of the nanopore for a bioanalyte traversing through. The optimized design was established to be a 1200 nm diameter cavity of 600 nm depth with a 50 nm square nanopore with rounded corners in the base. A gold 3D-structured membrane containing these sized microcavities with the integrated nanopore was successfully fabricated and ‘proof of concept’ Raman scattering experiments are described. PMID:26973809
NASA Technical Reports Server (NTRS)
Wehrmeyer, Joseph A.; Trinh, Huu Phuoc
2001-01-01
Propellant injector development at MSFC includes experimental analysis using optical techniques, such as Raman, fluorescence, or Mie scattering. For the application of spontaneous Raman scattering to hydrocarbon-fueled flows a technique needs to be developed to remove the interfering polycyclic aromatic hydrocarbon fluorescence from the relatively weak Raman signals. A current application of such a technique is to the analysis of the mixing and combustion performance of multijet, impinging-jet candidate fuel injectors for the baseline Mars ascent engine, which will burn methane and liquid oxygen produced in-situ on Mars to reduce the propellant mass transported to Mars for future manned Mars missions. The present technique takes advantage of the strongly polarized nature of Raman scattering. It is shown to be discernable from unpolarized fluorescence interference by subtracting one polarized image from another. Both of these polarized images are obtained from a single laser pulse by using a polarization-separating calcite rhomb mounted in the imaging spectrograph. A demonstration in a propane-air flame is presented.
Kaszowska, Zofia; Malek, Kamilla; Staniszewska-Slezak, Emilia; Niedzielska, Karina
2016-12-05
This work presents an in-depth study on Raman spectra excited with 1064 and 532nm lasers of lime binders employed in the past as building materials and revealed today as valuable conservation materials. We focus our interest on the bands of strong intensity, which are present in the spectra of all binders acquired with laser excitation at 1064nm, but absent in the corresponding spectra acquired with laser excitation at 532nm. We suggest, that the first group of spectra represents fluorescence phenomena of unknown origin and the second true Raman scattering. In our studies, we also include two other phases of lime cycle, i.e. calcium carbonate (a few samples of calcite of various origins) and calcium oxide (quicklime) to assess how structural and chemical transformations of lime phases affect the NIR-Raman spectral profile. Furthermore, we analyse a set of carbonated limewashes and lime binders derived from old plasters to give an insight into their spectral characteristics after excitation with the 1064nm laser line. NIR-Raman micro-mapping results are also presented to reveal the spatial distribution of building materials and fluorescent species in the cross-section of plaster samples taken from a 15th century chapel. Our study shows that the Raman analysis can help identify lime-based building and conservation materials, however, a caution is advised in the interpretation of the spectra acquired using 1064nm excitation. Copyright © 2016. Published by Elsevier B.V.
Femtosecond laser ablation of enamel
NASA Astrophysics Data System (ADS)
Le, Quang-Tri; Bertrand, Caroline; Vilar, Rui
2016-06-01
The surface topographical, compositional, and structural modifications induced in human enamel by femtosecond laser ablation is studied. The laser treatments were performed using a Yb:KYW chirped-pulse-regenerative amplification laser system (560 fs and 1030 nm) and fluences up to 14 J/cm2. The ablation surfaces were studied by scanning electron microscopy, grazing incidence x-ray diffraction, and micro-Raman spectroscopy. Regardless of the fluence, the ablation surfaces were covered by a layer of resolidified material, indicating that ablation is accompanied by melting of hydroxyapatite. This layer presented pores and exploded gas bubbles, created by the release of gaseous decomposition products of hydroxyapatite (CO2 and H2O) within the liquid phase. In the specimen treated with 1-kHz repetition frequency and 14 J/cm2, thickness of the resolidified material is in the range of 300 to 900 nm. The micro-Raman analysis revealed that the resolidified material contains amorphous calcium phosphate, while grazing incidence x-ray diffraction analysis allowed detecting traces of a calcium phosphate other than hydroxyapatite, probably β-tricalcium phosphate Ca3), at the surface of this specimen. The present results show that the ablation of enamel involves melting of enamel's hydroxyapatite, but the thickness of the altered layer is very small and thermal damage of the remaining material is negligible.
Moreira, M A; Souza, N O; Sousa, R S; Freitas, D Q; Lemos, M V; De Paula, D M; Maia, F J N; Lomonaco, D; Mazzetto, S E; Feitosa, V P
2017-10-01
Several polyphenols from renewable sources were surveyed for dentin biomodification. However, phenols from cashew nut shell liquid (CNSL, Anacardium occidentale) and from Aroeira (Myracrodruon urundeuva) extract have never been evaluated. The present investigation aimed to compare the dentin collagen crosslinking (biomodification) effectiveness of polyphenols from Aroeira stem bark extract, proanthocyanidins (PACs) from grape-seed extract (Vitis vinifera), cardol and cardanol from CNSL after clinically relevant treatment for one minute. Three-point bending test was used to obtain the elastic modulus of fully demineralized dentin beams before and after biomodification, whilst color change and mass variation were evaluated after four weeks water biodegradation. Color aspect was assessed by optical images after biodegradation whereas collagen cross-linking was investigated by micro-Raman spectroscopy. Statistical analysis was performed with repeated-measures two way ANOVA and Tukey's test (p<0.05). The increase in elastic modulus after biomodification was in the order cardol>cardanol>aroeira=PACs with cardol solution achieving mean 338.2% increase. The mass increase after biomodification followed the same order aforementioned. Nevertheless, after four weeks aging, more hydrophobic agent (cardanol) induced the highest resistance against water biodegradation. Aroeira and cardol attained intermediate outcomes whereas PACs provided the lower resistance. Tannin-based agents (Aroeira and PACs) stained the specimens in dark brown color. No color alteration was observed with cardol and cardanol treatments. All four agents achieved crosslinking in micro-Raman after one minute application. In conclusion, major components of CNSL yield overall best dentin biomodification outcomes when applied for one minute without staining the dentin collagen. Copyright © 2017 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Hu, Y.; Stender, D.; Medarde, M.; Lippert, T.; Wokaun, A.; Schneider, C. W.
2013-08-01
A detailed structural XRD analysis of (1 1 0)-oriented TbMnO3 thin films grown on (1 1 0)-YAlO3 substrates shows the co-existence of a strained and relaxed "sublayer" within the films due to strain relaxation during epitaxial growth by pulsed laser deposition. The substrate-film lattice mismatch yields a compressive strain anisotropy along the two in-plane directions, i.e. [1 -1 0] and [0 0 1] and a monoclinic distortion. A further manifestation of the growth-induced strain is the hardening of Raman active modes as a result of changed atomic motions along the [1 -1 0] and [0 0 1] directions.
Application of Raman spectroscopy technology to studying Sudan I
NASA Astrophysics Data System (ADS)
Li, Gang; Zhang, Guoping; Chen, Chen
2006-06-01
Being an industrial dye, the Sudan I may have a toxic effect after oral intake on the body, and has recently been shown to cause cancer in rats, mice and rabbits. Because China and some other countries have detected the Sudan I in samples of the hot chilli powder and the chilli products, it is necessary to study the characteristics of this dye. As one kind of molecule scattering spectroscopy, Raman spectroscopy is characterized by the frequency excursion caused by interactions of molecules and photons. The frequency excursion reflects the margin between certain two vibrational or rotational energy states, and shows the information of the molecule. Because Raman spectroscopy can provides quick, easy, reproducible, and non-destructive analysis, both qualitative and quantitative, with no sample preparation required, Raman spectroscopy has been a particularly promising technique for analyzing the characteristics and structures of molecules, especially organic ones. Now, it has a broad application in biological, chemical, environmental and industrial applications. This paper firstly introduces Sudan I dye and the Raman spectroscopy technology, and then describes its application to the Sudan I. Secondly, the fingerprint spectra of the Sudan I are respectively assigned and analyzed in detail. Finally, the conclusion that the Raman spectroscopy technology is a powerful tool to determine the Sudan I is drawn.
Tu, Haohua; Boppart, Stephen A.
2015-01-01
Clinical translation of coherent anti-Stokes Raman scattering microscopy is of great interest because of the advantages of noninvasive label-free imaging, high sensitivity, and chemical specificity. For this to happen, we have identified and review the technical barriers that must be overcome. Prior investigations have developed advanced techniques (features), each of which can be used to effectively overcome one particular technical barrier. However, the implementation of one or a small number of these advanced features in previous attempts for clinical translation has often introduced more tradeoffs than benefits. In this review, we outline a strategy that would integrate multiple advanced features to overcome all the technical barriers simultaneously, effectively reduce tradeoffs, and synergistically optimize CARS microscopy for clinical translation. The operation of the envisioned system incorporates coherent Raman micro-spectroscopy for identifying vibrational biomolecular markers of disease and single-frequency (or hyperspectral) Raman imaging of these specific biomarkers for real-time in vivo diagnostics and monitoring. An optimal scheme of clinical CARS micro-spectroscopy for thin ex vivo tissues. PMID:23674234
Micro-Raman imaging on 4H-SiC in contact with the electrode at room temperature
NASA Astrophysics Data System (ADS)
Suda, Jun; Suwa, Satoshi; Mizuno, Shugo; Togo, Kouki; Mastuo, Yuya
2018-03-01
Raman images (30 μm × 30 μm × 180 μm) of a bulk 4H-SiC wafer in contact with a Ni/Au electrode film in 100 nm/200 nm thick were measured with Micro-Raman spectroscopy at room temperature. As the imaging area approached the interface between the SiC and electrode, the center frequency of the E2(TO) mode (778 cm- 1) immediately declined; in the Raman imaging, relative distribution of compressive residual stress around residual tensile stress, and linewidth were broadened due to crystal distortion. For LOPC (LO-phonon-plasmon-coupled) mode (970 cm- 1), center frequency showed variation right next to the interface, while linewidth decreased slowly as the imaging area approached the interface. We evaluated the temperature dependence of the line broadening and the center frequency of the LOPC mode in 4H-SiC in a high-temperature region. Free carrier concentration increased with temperature, and remained almost constant in the center frequency after impurities were ionized completely.
Multi-Functional UV-Visible-IR Nanosensors Devices and Structures
2015-04-29
Dual-Gate MOSFET System, Proceedings of the International Workshop on Computational Electronics, Nara, Japan, Society of Micro- and Nanoelectronics ...International Workshop on Computational Electronics, Nara, Japan, Society of Micro- and Nanoelectronics , 216-217 (2013); ISBN 978-3-901578-26-7 M. S...Raman Spectroscopy, Proceedings of the International Workshop on Computational Electronics, Nara, Japan, Society of Micro- and Nanoelectronics , 198
Optical and structural properties of individual Co-doped ZnO microwires
NASA Astrophysics Data System (ADS)
Kolomys, O. F.; Strelchuk, V. V.; Rarata, S. V.; Hayn, R.; Savoyant, A.; Giovannelli, F.; Delorme, F.; Tkach, V.
2018-06-01
The Co-doped ZnO microwires (MWs) were grown using the optical furnace method. We used Scanning electron microscopy (SEM), polarized micro-Raman spectroscopy, photoluminescence (PL) and optical absorption spectroscopy to systematic investigation of the optical and structural properties of Co-doped ZnO MWs. The SEM analysis reveals that Co-doped ZnO MWs has hexagonal facets and cavity inside. The EDS results confirmed the presence and non-uniform distribution of Co impurities in the samples. Co doping of ZnO MWs leads to the decreased intensity, drastically broadening and high-energy shift of the NBE PL band. The red emission band at 1.85 eV originates from 2E(2G) → 4A2 (4F) intra-3d-transition of Co2+ in the ZnO lattice has been observed. The intense structured absorption bands within the near infrared ranges 3800-4800 and 5500-9000 cm-1 are caused by electronic spin-allowed transitions 4T2(F) ← 4A2(F) and 4T1(F) ← 4A2(F) of the tetrahedrally coordinated Co2+ (3 d7) ions substituting Zn2+ ions in Co-doped ZnO MWs. Micro-Raman studies of Co doped ZnO MWs show doping/disorder induced additional modes as compared to the undoped sample. The resonant enhancement of the additional local Co-related A1-symmetry Raman mode is observed in the parallel polarization geometry y(z , z) ybar . For the Co doped ZnO MWs, the enhancement of the additional Co-related local vibration mode with an increase in the excitation photon energy is also observed in the Raman spectra.
Hall, Edward K.; Singer, Gabriel A.; Pölzl, Marvin; Hämmerle, Ieda; Schwarz, Christian; Daims, Holger; Maixner, Frank; Battin, Tom J.
2011-01-01
Stoichiometry of microbial biomass is a key determinant of nutrient recycling in a wide variety of ecosystems. However, little is known about the underlying causes of variance in microbial biomass stoichiometry. This is primarily because of technological constraints limiting the analysis of macromolecular composition to large quantities of microbial biomass. Here, we use Raman microspectroscopy (MS), to analyze the macromolecular composition of single cells of two species of bacteria grown on minimal media over a wide range of resource stoichiometry. We show that macromolecular composition, determined from a subset of identified peaks within the Raman spectra, was consistent with macromolecular composition determined using traditional analytical methods. In addition, macromolecular composition determined by Raman MS correlated with total biomass stoichiometry, indicating that analysis with Raman MS included a large proportion of a cell's total macromolecular composition. Growth phase (logarithmic or stationary), resource stoichiometry and species identity each influenced each organism's macromolecular composition and thus biomass stoichiometry. Interestingly, the least variable peaks in the Raman spectra were those responsible for differentiation between species, suggesting a phylogenetically specific cellular architecture. As Raman MS has been previously shown to be applicable to cells sampled directly from complex environments, our results suggest Raman MS is an extremely useful application for evaluating the biomass stoichiometry of environmental microorganisms. This includes the ability to partition microbial biomass into its constituent macromolecules and increase our understanding of how microorganisms in the environment respond to resource heterogeneity.
Hall, Edward K; Singer, Gabriel A; Pölzl, Marvin; Hämmerle, Ieda; Schwarz, Christian; Daims, Holger; Maixner, Frank; Battin, Tom J
2011-01-01
Stoichiometry of microbial biomass is a key determinant of nutrient recycling in a wide variety of ecosystems. However, little is known about the underlying causes of variance in microbial biomass stoichiometry. This is primarily because of technological constraints limiting the analysis of macromolecular composition to large quantities of microbial biomass. Here, we use Raman microspectroscopy (MS), to analyze the macromolecular composition of single cells of two species of bacteria grown on minimal media over a wide range of resource stoichiometry. We show that macromolecular composition, determined from a subset of identified peaks within the Raman spectra, was consistent with macromolecular composition determined using traditional analytical methods. In addition, macromolecular composition determined by Raman MS correlated with total biomass stoichiometry, indicating that analysis with Raman MS included a large proportion of a cell's total macromolecular composition. Growth phase (logarithmic or stationary), resource stoichiometry and species identity each influenced each organism's macromolecular composition and thus biomass stoichiometry. Interestingly, the least variable peaks in the Raman spectra were those responsible for differentiation between species, suggesting a phylogenetically specific cellular architecture. As Raman MS has been previously shown to be applicable to cells sampled directly from complex environments, our results suggest Raman MS is an extremely useful application for evaluating the biomass stoichiometry of environmental microorganisms. This includes the ability to partition microbial biomass into its constituent macromolecules and increase our understanding of how microorganisms in the environment respond to resource heterogeneity. PMID:20703314
Effect of infrared light on live blood cells: Role of β-carotene.
Barkur, Surekha; Bankapur, Aseefhali; Chidangil, Santhosh; Mathur, Deepak
2017-06-01
We have utilized Raman tweezers to measure and assign micro-Raman spectra of optically trapped, live red blood cells (RBCs), white blood cells (WBCs) and platelets. Various types of WBCs- both granulocytes, lymphocytes, and their different types have been studied. The Raman bands are assigned to different biomolecules of blood cells. The Raman spectra thus obtained has been enabled detection of β-carotene in these blood cells, the spectral features of which act as a signature that facilitates experimental probing of the effect of 785nm laser light on different blood cells as a function of incident laser power in the mW range. The spectral changes that we obtain upon laser irradiation indicate that, both haemoglobin as well as the cell membrane sustains damage. In case of lymphocytes and platelets the peaks corresponding to β-carotene showed drastic changes. Thorough analysis of the spectral changes indicates possibility of free radical induced damage of β-carotene in lymphocytes and platelets. Among different blood cells, RBCs have a power threshold of only 10mW. The power threshold for other types of blood cells is somewhat higher, but always below about 30mW. These values are likely to serve as useful guides for Raman tweezers based experiments on live cells. Copyright © 2017. Published by Elsevier B.V.
Micro Raman and photoluminescence spectroscopy of nano-porous n and p type GaN/sapphire(0001).
Ingale, Alka; Pal, Suparna; Dixit, V K; Tiwari, Pragya
2007-06-01
Variation of depth within a single etching spot (3 mm circular diameter) was observed in nanoporous GaN epilayer obtained on photo-assisted electrochemical etching of n and p-type GaN. The different etching depth regions were studied using microRaman and PL(yellow region) for both n-type and p-type GaN. From Raman spectroscopy, we observed that increase in disorder is accompanied by stress relaxation, as depth of etching increases for n-type GaN epilayer. This is well corroborated with scanning electron microscopy results. Contrarily, for p-type GaN epilayer we found that for minimum etching depth, stress in epilayer increases with increase in disorder. This is understood with the fact that as grown p-type GaN is more disordered compared to n-type GaN due to heavy Mg doping and further disorder leads to lattice distortion leading to increase in stress.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gautam, Subodh K.; Singh, Fouran, E-mail: fouran@gmail.com; Sulania, I.
2014-04-14
Softening and stiffening of phonons in rutile titanium dioxide films are investigated by in situ micro-Raman studies during energetic ion irradiation. The in situ study minimized other possible mechanisms of phonon dynamics. Initial softening and broadening of Raman shift are attributed to the phonon confinement by structural defects and loss of stoichiometry. The stiffening of A{sub 1g} mode is ascribed to large distortion of TiO{sub 6} octahedra under the influence of lattice strain in the (110) plane, which gives rise to lengthening of equatorial Ti-O bond and shortening of apical Ti-O bond. The shortening of apical Ti-O bond induces stiffeningmore » of A{sub 1g} mode in the framework of the bond-order-length-strength correlation mechanism.« less
Full-field fabric stress mapping by micro Raman spectroscopy in a yarn push-out test.
Lei, Z K; Qin, F Y; Fang, Q C; Bai, R X; Qiu, W; Chen, X
2018-02-01
The full-field stress distribution of a two-dimensional plain fabric was mapped using micro Raman spectroscopy (MRS) through a novel yarn push-out test, simulating a quasi-static projectile impact on the fabric. The stress-strain relationship for a single yarn was established using a digital image correlation method in a single-yarn tensile test. The relationship between Raman peak shift and aramid Kevlar 49 yarn stress was established using MRS in a single-yarn tensile test. An out-of-plane loading test was conducted on an aramid Kevlar 49 plain fabric, and the yarn stress was measured using MRS. From the full-field fabric stress distribution, it can be observed that there is a cross-shaped distribution of high yarn stress; this result would be helpful in further studies on load transfer on a fabric during a projectile impact.
NASA Astrophysics Data System (ADS)
Ayars, Eric James
2000-10-01
The purpose of this research is to investigate differences observed between Raman spectra when seen through a Near-field Scanning Optical Microscope (NSOM) and spectra of the same materials in conventional Raman or micro-Raman configurations. One source of differences in the observed spectra is a strong z polarized component in the near-field radiation; observations of the magnitude of this effect are compared with theoretical predictions for the field intensity near an NSOM tip. Large electric field gradients near the sharp NSOM probe may be another source of differences. This Gradient-Field Raman (GFR) effect was observed, and there is good evidence that it plays a significant role in Surface-Enhanced Raman Spectroscopy (SERS). The NSOM data seen, however, are not sufficient to prove conclusively that the spectral variations seen are due to the field gradients.
Tailoring metal/metal oxide nanostructures for ultra-sensitive detection
NASA Astrophysics Data System (ADS)
Morrill, Andrew Reese
This thesis presents three diverse approaches to harnessing the material properties of nanostructures to produce ultra-sensitive detection platforms. In this work we have utilized nanostructure synthesis as the launching point for the creation of nanodevices with applications in chemical and biological sensing, catalysis and metrology. Silver nanowires were electrodeposited into a porous aluminum oxide (PAO) template. When these templates are chemically etched the nanowires become exposed and eventually collapse into bundles that harbor interstices that function as "hot-spots" for Raman field enhancement. Surface enhanced Raman spectroscopy experiments were carried out on these substrates in two ways using benzenethiol as the Raman probe. In both experiments the SERS spectra show significant (˜25 and ˜50 fold respectively) increase in intensity over the initial value (when the tips were barely exposed). Nanostructured titania (NST) thin films were produced by oxidizing titanium with hydrogen peroxide. These films are particularly well suited for integration into microfabricated sensing devices. The formation of NST relies on a re-deposition process in which an adequate amount of Ti-peroxo species must be generated and remain at the solid-solution interface. To reliably produce arrays of micro-patterned NST films on the wafer scale a patterning guide was developed and tested. Wafer scale arrays of NST micro gas-sensors have been fabricated using standard thin film techniques. Sensing elements are 20 mum on a side. High sensitivity to hydrogen is achieved by modification of the sensors with platinum nanoparticles. When exposed to 10 mT of hydrogen at 250°C, the functionalized devices exhibit more than one order of magnitude decrease in resistance with a response time of ˜7 seconds. Both NST and tin (IV) oxide nanowires were coated in aminosilane self-assembled monolayers (SAMs) which have many applications in binding biomolecules. There has been a plethora of characterization techniques developed for SAMs but unluckily most of them rely on the SAM being on a planar surface. By "tailoring" our aminosilane SAM modified NSMO surfaces with borohydride reduced silver nanoparticles (AgNP) we are able to reliably image the SAMs using scanning electron microscopy (SEM). These AgNP modified SAMs may have many applications in catalysis, sensing and SERS.
GaN epitaxial layers grown on multilayer graphene by MOCVD
NASA Astrophysics Data System (ADS)
Li, Tianbao; Liu, Chenyang; Zhang, Zhe; Yu, Bin; Dong, Hailiang; Jia, Wei; Jia, Zhigang; Yu, Chunyan; Gan, Lin; Xu, Bingshe
2018-04-01
In this study, GaN epitaxial layers were successfully deposited on a multilayer graphene (MLG) by using metal-organic chemical vapor deposition (MOCVD). Highly crystalline orientations of the GaN films were confirmed through electron backscatter diffraction (EBSD). An epitaxial relationship between GaN films and MLG is unambiguously established by transmission electron microscope (TEM) analysis. The Raman spectra was used to analyze the internal stress of GaN films, and the spectrum shows residual tensile stress in the GaN films. Moreover, the results of the TEM analysis and Raman spectra indicate that the high quality of the MLG substrate is maintained even after the growth of the GaN film. This high-quality MLG makes it possible to easily remove epitaxial layers from the supporting substrate by micro-mechanical exfoliation technology. This work can aid in the development of transferable devices using GaN films.
NASA Astrophysics Data System (ADS)
Bagnall, Kevin R.; Wang, Evelyn N.
2016-06-01
Micro-Raman thermography is one of the most popular techniques for measuring local temperature rise in gallium nitride (GaN) high electron mobility transistors with high spatial and temporal resolution. However, accurate temperature measurements based on changes in the Stokes peak positions of the GaN epitaxial layers require properly accounting for the stress and/or strain induced by the inverse piezoelectric effect. It is common practice to use the pinched OFF state as the unpowered reference for temperature measurements because the vertical electric field in the GaN buffer that induces inverse piezoelectric stress/strain is relatively independent of the gate bias. Although this approach has yielded temperature measurements that agree with those derived from the Stokes/anti-Stokes ratio and thermal models, there has been significant difficulty in quantifying the mechanical state of the GaN buffer in the pinched OFF state from changes in the Raman spectra. In this paper, we review the experimental technique of micro-Raman thermography and derive expressions for the detailed dependence of the Raman peak positions on strain, stress, and electric field components in wurtzite GaN. We also use a combination of semiconductor device modeling and electro-mechanical modeling to predict the stress and strain induced by the inverse piezoelectric effect. Based on the insights gained from our electro-mechanical model and the best values of material properties in the literature, we analyze changes in the E2 high and A1 (LO) Raman peaks and demonstrate that there are major quantitative discrepancies between measured and modeled values of inverse piezoelectric stress and strain. We examine many of the hypotheses offered in the literature for these discrepancies but conclude that none of them satisfactorily resolves these discrepancies. Further research is needed to determine whether the electric field components could be affecting the phonon frequencies apart from the inverse piezoelectric effect in wurtzite GaN, which has been predicted theoretically in zinc blende gallium arsenide (GaAs).
NASA Astrophysics Data System (ADS)
Vieira Ferreira, L. F.; Casimiro, T. M.; Colomban, Ph.
2013-03-01
Two sherds representative of the Portuguese faience production of the first and second halves of the 17th century were studied carefully with the use of non-invasive spectroscopies, namely: Ground State Diffuse Reflectance Absorption (GSDR), micro-Raman, Fourier-Transform Infrared (FT-IR), Laser Induced Luminescence (LIL) and Proton Induced X-ray (PIXE). These results were compared with the ones obtained for a Chinese Ming porcelain, Wanli period (16th/beginning of the 17th centuries), which served as an influence for the initial Lisbon's faience production. By combining information of the different non-destructive spectroscopic techniques used in this work, it was possible to conclude that: Co3O4 (Co II and Co III) can be found in the silicate matrix and is the blue pigment in the "Especieiro" sample (1st half of the 17th C.). Cobalt olivine silicate (Co2SiO4, Co II only) was clearly identified as the blue pigment in "Aranhões" sample (2nd half of the17th C.) - 824 cm-1 band in the micro-Raman-spectrum. Cobalt aluminate (CoAl2O4, Co II only) is the blue pigment in the Wanli plate - 203 and 512 cm-1 bands in the micro-Raman spectrum. The blue pigment in the 1st half 17th century of Lisbon's production was obtained by addition of a cobalt ore in low concentrations, which gives no specific Raman signature, because of complete dissolution in the glass. However, in most cases of the 2nd half 17th century, the Raman signature was quite evident, from a cobalt silicate. These findings point to the use of higher temperature kilns in the second case.
Nanostructured optical fibre arrays for high-density biochemical sensing and remote imaging.
Deiss, F; Sojic, N; White, D J; Stoddart, P R
2010-01-01
Optical fibre bundles usually comprise a few thousand to tens of thousands of individually clad glass optical fibres. The ordered arrangement of the fibres enables coherent transmission of an image through the bundle and therefore enables analysis and viewing in remote locations. In fused bundles, this architecture has also been used to fabricate arrays of various micro to nano-scale surface structures (micro/nanowells, nanotips, triangles, etc.) over relatively large areas. These surface structures have been used to obtain new optical and analytical capabilities. Indeed, the imaging bundle can be thought of as a "starting material" that can be sculpted by a combination of fibre drawing and selective wet-chemical etching processes. A large variety of bioanalytical applications have thus been developed, ranging from nano-optics to DNA nanoarrays. For instance, nanostructured optical surfaces with intrinsic light-guiding properties have been exploited as surface-enhanced Raman scattering (SERS) platforms and as near-field probe arrays. They have also been productively associated with electrochemistry to fabricate arrays of transparent nanoelectrodes with electrochemiluminescent imaging properties. The confined geometry of the wells has been loaded with biosensing materials and used as femtolitre-sized vessels to detect single molecules. This review describes the fabrication of high-density nanostructured optical fibre arrays and summarizes the large range of optical and bioanalytical applications that have been developed, reflecting the versatility of this ordered light-guiding platform.
Multivariate reference technique for quantitative analysis of fiber-optic tissue Raman spectroscopy.
Bergholt, Mads Sylvest; Duraipandian, Shiyamala; Zheng, Wei; Huang, Zhiwei
2013-12-03
We report a novel method making use of multivariate reference signals of fused silica and sapphire Raman signals generated from a ball-lens fiber-optic Raman probe for quantitative analysis of in vivo tissue Raman measurements in real time. Partial least-squares (PLS) regression modeling is applied to extract the characteristic internal reference Raman signals (e.g., shoulder of the prominent fused silica boson peak (~130 cm(-1)); distinct sapphire ball-lens peaks (380, 417, 646, and 751 cm(-1))) from the ball-lens fiber-optic Raman probe for quantitative analysis of fiber-optic Raman spectroscopy. To evaluate the analytical value of this novel multivariate reference technique, a rapid Raman spectroscopy system coupled with a ball-lens fiber-optic Raman probe is used for in vivo oral tissue Raman measurements (n = 25 subjects) under 785 nm laser excitation powers ranging from 5 to 65 mW. An accurate linear relationship (R(2) = 0.981) with a root-mean-square error of cross validation (RMSECV) of 2.5 mW can be obtained for predicting the laser excitation power changes based on a leave-one-subject-out cross-validation, which is superior to the normal univariate reference method (RMSE = 6.2 mW). A root-mean-square error of prediction (RMSEP) of 2.4 mW (R(2) = 0.985) can also be achieved for laser power prediction in real time when we applied the multivariate method independently on the five new subjects (n = 166 spectra). We further apply the multivariate reference technique for quantitative analysis of gelatin tissue phantoms that gives rise to an RMSEP of ~2.0% (R(2) = 0.998) independent of laser excitation power variations. This work demonstrates that multivariate reference technique can be advantageously used to monitor and correct the variations of laser excitation power and fiber coupling efficiency in situ for standardizing the tissue Raman intensity to realize quantitative analysis of tissue Raman measurements in vivo, which is particularly appealing in challenging Raman endoscopic applications.
Raman spectroscopy for the identification of pigments and color measurement in Dugès watercolors
NASA Astrophysics Data System (ADS)
Frausto-Reyes, C.; Ortiz-Morales, M.; Bujdud-Pérez, J. M.; Magaña-Cota, G. E.; Mejía-Falcón, R.
2009-12-01
Spectroscopic and colorimetric analysis of a representative set of Dugès watercolor paintings was performed. These paintings were the result of scientific studies carried out by the zoologist Alfredo Dugès, who recorded the fauna of the Mexican Republic between 1853 and 1910. Micro-Raman spectroscopy, with an excitation wavelength of 830 nm, and colorimetric techniques were employed in order to understand if different colors with the same hue were reproduced using the same pigments. The color coordinates of the measured areas were obtained in the CIE L* a* b* color space. Raman analysis showed that, in some cases, to reproduce colors with the same hue the pigment employed was not the same. Pigments identified in the watercolors were vermilion, carbon-based black, lead white, gamboge and chrome yellow, Prussian and ultramarine blue. Some of these pigments have been used since ancient times, others as Prussian blue, chrome yellow and synthetic ultramarine blue arrived to the market at the beginning of the 18th and 19th centuries, respectively. Furthermore, regarding the white color, instead of left the paper unpainted, lead white was detected in the eye of a bird. The green color was obtained by mixing Prussian blue with chrome yellow. The results of this work show the suitability of using Raman spectroscopy for watercolor pigment analysis and colorimetric techniques to measure the color of small areas (246 μm × 246 μm) that was the case for the lead white pigment.
Non-invasive and micro-destructive investigation of the Domus Aurea wall painting decorations.
Clementi, Catia; Ciocan, Valeria; Vagnini, Manuela; Doherty, Brenda; Tabasso, Marisa Laurenzi; Conti, Cinzia; Brunetti, Brunetto Giovanni; Miliani, Costanza
2011-10-01
The paper reports on the exploitation of an educated multi-technique analytical approach based on a wide non invasive step followed by a focused micro-destructive step, aimed at the minimally invasive identification of the pigments decorating the ceiling of the Gilded Vault of the Domus Aurea in Rome. The combination of elemental analysis with molecular characterization provided by X-ray fluorescence and UV-vis spectroscopies, respectively, allowed for the in situ non-invasive identification of a remarkable number of pigments, namely Egyptian blue, green earth, cinnabar, red ochre and an anthraquinonic lake. The study was completed with the Raman analysis of two bulk samples, in particular, SERS measurements allowed for the speciation of the anthraquinonic pigment. Elemental mapping by scanning electron microscopy-energy dispersive spectrometer combined with micro-fluorimetry on cross-section gave an insight into both the distribution of different blend of pigments and on the nature of the inorganic support of the red dye.
NASA Astrophysics Data System (ADS)
Yang, Chun-Chen; Chiu, Shwu-Jer; Chien, Wen-Chen; Chiu, Sheng-Shin
The quaternized poly(vinyl alcohol)/alumina (designated as QPVA/Al 2O 3) nanocomposite polymer membrane was prepared by a solution casting method. The characteristic properties of the QPVA/Al 2O 3 nanocomposite polymer membranes were investigated using thermal gravimetric analysis (TGA), scanning electron microscopy (SEM), dynamic mechanical analysis (DMA), micro-Raman spectroscopy, and AC impedance method. Alkaline direct methanol fuel cell (ADMFC) comprised of the QPVA/Al 2O 3 nanocomposite polymer membrane were assembled and examined. Experimental results indicate that the DMFC employing a cheap non-perfluorinated (QPVA/Al 2O 3) nanocomposite polymer membrane shows excellent electrochemical performances. The peak power densities of the DMFC with 4 M KOH + 1 M CH 3OH, 2 M CH 3OH, and 4 M CH 3OH solutions are 28.33, 32.40, and 36.15 mW cm -2, respectively, at room temperature and in ambient air. The QPVA/Al 2O 3 nanocomposite polymer membranes constitute a viable candidate for applications on alkaline DMFC.
Schäfer-Nolte, E O; Stoica, T; Gotschke, T; Limbach, F A; Sutter, E; Sutter, P; Grützmacher, D; Calarco, R
2010-08-06
In the literature, there are controversies on the interpretation of the appearance in InN Raman spectra of a strong scattering peak in the energy region of the unscreened longitudinal optical (LO) phonons, although a shift caused by the phonon-plasmon interaction is expected for the high conductance observed in this material. Most measurements on light scattering are performed on ensembles of InN nanowires (NWs). However, it is important to investigate the behavior of individual nanowires and here we report on micro-Raman measurements on single nanowires. When changing the polarization direction of the incident light from parallel to perpendicular to the wire, the expected reduction of the Raman scattering was observed for transversal optical (TO) and E(2) phonon scattering modes, while a strong symmetry-forbidden LO mode was observed independently on the laser polarization direction. Single Mg- and Si-doped crystalline InN nanowires were also investigated. Magnesium doping results in a sharpening of the Raman peaks, while silicon doping leads to an asymmetric broadening of the LO peak. The results can be explained based on the influence of the high electron concentration with a strong contribution of the surface accumulation layer and the associated internal electric field.
Raman Spectroscopy: an essential tool for future IODP expeditions
NASA Astrophysics Data System (ADS)
Andò, Sergio; Garzanti, Eduardo; Kulhanek, Denise K.
2016-04-01
The scientific drilling of oceanic sedimentary sequences plays a fundamental part in provenance studies, paleoclimate recostructions, and source-to-sink investigations (e.g., France-Lanord et al., 2015; Pandey et al., 2015). When studying oceanic deposits, Raman spectroscopy can and does represent an essential flexible tool for the multidisciplinary approach necessary to integrate the insight provided by different disciplines. This new user-friendly technique opens up an innovative avenue to study in real time the composition of detrital mineral grains of any origin, complementing traditional methods of provenance analysis (e.g., sedimentary petrography, heavy minerals; Andò and Garzanti, 2014). Raman spectra can readily reveal the chemistry of foraminiferal tests, nannofossils and other biogenic debris for the study of ecosystem evolution and paleoclimate, or the Ca/Mg ratio in biogenic or terrigenous carbonates for geological or marine biological applications and oil exploration (Borromeo et al., 2015). For the study of pelagic or turbiditic muds, which represent the bulk of the deep-marine sedimentary record, Raman spectroscopy allows us to identify silt-sized grains down to the size of a few microns with the same precision level required in quantitative provenance analysis of sand-sized sediments (Andò et al., 2011). Silt and siltstone also represent a very conspicuous part of the stratigraphic record onshore and usually preserve original mineralogical assemblages better than more permeable interbedded sand and sandstone (Blatt, 1985). Raman spectra can be obtained on sample volumes of only a few cubic microns by a confocal micro-Raman coupled with a standard polarizing light microscope using a 50× objective. The size of this apparatus can be easily placed onboard an IODP vessel to provide crucial information and quickly solve identification problems for the benefit of a wide range of scientists during future expeditions. Cited references Andò, S., Vignola, P., Garzanti, E., 2011. Raman counting: a new method to determine provenance of silt. Rend. Fis. Acc. Lincei, 22: 327-347. Andò, S., Garzanti, E., 2014. Raman spectroscopy in heavy-mineral studies. Geological Society, London, Special Publications, 386 (1), 395-412. Blatt, H., (1985). Provenance studies and mudrocks. Journal of Sedimentary Research, 55 (1), 69-75. Borromeo, L., Zimmermann, U., Andò, S., Coletti, G., Bersani, D., Basso, D., Gentile, P., Garzanti, E., 2015. Raman Spectroscopy as a tool for magnesium estimation in Mg-calcite. Periodico di Mineralogia , ECMS, 35-36. France-Lanord, C., Spiess, V., Klaus, A., and the Expedition 354 Scientists, 2015. IODP, Exp. 354, Preliminary Report: Bengal Fan, Neogene and late Paleogene record of Himalayan orogeny and climate: a transect across the Middle Bengal Fan. Pandey, D.K., Clift, P.D., Kulhanek, D.K. and the Expedition 355 Scientists, 2015. IODP, Exp. 355, Preliminary Report: Arabian Sea Monsoon, Deep sea drilling in the Arabian Sea: constraining tectonic-monsoon interactions in South Asia.
Directed assembly of colloidal particles for micro/nano photonics (Conference Presentation)
NASA Astrophysics Data System (ADS)
Zheng, Yuebing
2017-02-01
Bottom-up fabrication of complex structures with chemically synthesized colloidal particles as building blocks pave an efficient and cost-effective way towards micro/nano photonics with unprecedented functionality and tunability. Novel properties can arise from quantum effects of colloidal particles, as well as inter-particle interactions and spatial arrangement in particle assemblies. Herein, I discuss our recent developments and applications of three types of techniques for directed assembly of colloidal particles: moiré nanosphere lithography (MNSL), bubble-pen lithography (BPL), and optothermal tweezers (OTTs). Specifically, MNSL provides an efficient approach towards creating moiré metasurface with tunable and multiband optical responses from visible to mid-infrared regime. Au moiré metasurfaces have been applied for surface-enhanced infrared spectroscopy, optical capture and patterning of bacteria, and photothermal denaturation of proteins. BPL is developed to pattern a variety of colloidal particles on plasmonic substrates and two-dimensional atomic-layer materials in an arbitrary manner. The laser-directed microbubble captures and immobilizes nanoparticles through coordinated actions of Marangoni convection, surface tension, gas pressure, and substrate adhesion. OTTs are developed to create dynamic nanoparticle assemblies at low optical power. Such nanoparticle assemblies have been used for surface-enhanced Raman spectroscopy for molecular analysis in their native environments.
Applications and theory of electrokinetic enrichment in micro-nanofluidic chips.
Chen, Xueye; Zhang, Shuai; Zhang, Lei; Yao, Zhen; Chen, Xiaodong; Zheng, Yue; Liu, Yanlin
2017-09-01
This review reports the progress on the recent development of electrokinetic enrichment in micro-nanofluidic chips. The governing equations of electrokinetic enrichment in micro-nanofluidic chips are given. Various enrichment applications including protein analysis, DNA analysis, bacteria analysis, viruses analysis and cell analysis are illustrated and discussed. The advantages and difficulties of each enrichment method are expatiated. This paper will provide a particularly convenient and valuable reference to those who intend to research the electrokinetic enrichment based on micro-nanofluidic chips.
Angular dispersion of oblique phonon modes in BiFeO3 from micro-Raman scattering
NASA Astrophysics Data System (ADS)
Hlinka, J.; Pokorny, J.; Karimi, S.; Reaney, I. M.
2011-01-01
The angular dispersion of oblique phonon modes in a multiferroic BiFeO3 has been obtained from a micro-Raman spectroscopic investigation of a coarse grain ceramic sample. Continuity of the measured angular dispersion curves allows conclusive identification of all pure zone-center polar modes. The method employed here to reconstruct the anisotropic crystal property from a large set of independent local measurements on a macroscopically isotropic ceramic sample profits from the considerable dispersion of the oblique modes in ferroelectric perovskites and it can be in principle conveniently applied to any other optically uniaxial ferroelectric material.
Interfacial Micromechanics in Fibrous Composites: Design, Evaluation, and Models
Lei, Zhenkun; Li, Xuan; Qin, Fuyong; Qiu, Wei
2014-01-01
Recent advances of interfacial micromechanics in fiber reinforced composites using micro-Raman spectroscopy are given. The faced mechanical problems for interface design in fibrous composites are elaborated from three optimization ways: material, interface, and computation. Some reasons are depicted that the interfacial evaluation methods are difficult to guarantee the integrity, repeatability, and consistency. Micro-Raman study on the fiber interface failure behavior and the main interface mechanical problems in fibrous composites are summarized, including interfacial stress transfer, strength criterion of interface debonding and failure, fiber bridging, frictional slip, slip transition, and friction reloading. The theoretical models of above interface mechanical problems are given. PMID:24977189
NASA Astrophysics Data System (ADS)
Guerain, M.; Goudeau, P.; Panicaud, B.; Grosseau-Poussard, J. L.
2013-02-01
Spontaneous delamination process for α-Cr2O3 thermal oxide films growing on NiCr-30 alloys is studied thanks to micro Raman spectroscopy. In particular, stress maps are performed through and around buckles developed on chromia films. Depending on the cooling rate at the end of the oxidation process, different buckle types appear which are investigated. Associated residual stress distribution clearly evidences the stress release field. In addition, geometrical features are determined for the different buckle types, and from comparison with modelling describing buckle formation and propagation, it is possible to get the interface toughness distribution.
NASA Astrophysics Data System (ADS)
Lu, Fei; Guo, Yue; Wang, Yunxin; Song, Wei; Zhao, Bing
2018-05-01
In this study, we have investigated the effect of the surface morphologies of the zinc oxide (ZnO) substrates on surface enhanced Raman spectroscopy (SERS). During synthetic process, the self-assembly monolayers (SAMs) with different terminal groups are used as templates to induce the nucleation and growth of Zn(NO3)2·6H2O crystals, then different morphologies micro-nano ZnO powders are obtained by annealing Zn(NO3)2·6H2O crystals at 450 °C. The products obtained at different conditions are characterized by means of X-ray diffraction (XRD) patterns, scanning electron microscopy (SEM) and Raman spectra. The as-prepared ZnO micro-sized particles have been used the efficient Surface enhanced Raman scattering (SERS) substrates, and the SERS signals of 4-mercaptopyridine (Mpy) probe molecules are much influenced by the morphologies of the ZnO structures. Results indicated that the more (0001) facets appear in the of ZnO morphology, the greater degree of charge-transfer (PCT) for the SERS enhancement on the surface of semiconductors is achieved. The chemical interaction between ZnO structures and Mpy molecules plays a very important role in the SERS enhancement.
The reliability of Raman micro-spectroscopy in measuring the density of CO2 mantle fluids
NASA Astrophysics Data System (ADS)
Remigi, S.; Frezzotti, M. L.; Ferrando, S.; Villa, I. M.; Maffeis, A.
2017-12-01
Recent evaluations of carbon fluxes into and out the Earth's interior recognize that a significant part of the total outgassing of deep Earth carbon occurs in tectonically active areas (Kelemen and Manning, 2015). Potential tracers of carbon fluxes at mantle depths include CO2 fluid inclusions in peridotites. Raman micro-spectroscopy allows calculating the density of CO2 fluids based on the distance of the CO2 Fermi doublet, Δ, in cm-1 (Rosso and Bodnar, 1995). The aim of this work is to check the reliability of Raman densimeter equations (cf. Lamadrid et al., 2016) for high-density CO2 fluids originating at mantle depths. Forty pure CO2 inclusions in peridotites (El Hierro, Canary Islands) of known density (microthermometry) have been analyzed by Raman micro-spectroscopy. In order to evaluate the influence of contaminants on the reliability of equations, 22 CO2-rich inclusions containing subordinate amounts of N2, CO, SO2 have also been studied. Raman spectrometer analytical conditions are: 532 nm laser, 80 mW emission power, T 18°C, 1800 and 600 grating, 1 accumulation x 80 sec. Daily calibration included diamond and atmosphere N2. Results suggest that the "Raman densimeter" represents an accurate method to calculate the density of CO2 mantle fluids. Equations, however, must be applied only to pure CO2 fluids, since contaminants, even in trace amounts (0.39 mol%), affect the Δ resulting in density overestimation. Present study further highlights how analytical conditions and data processing, such as spectral resolution (i.e., grating), calibration linearity, and statistical treatment of spectra, influence the accuracy and the precision of Δ measurements. As a consequence, specific analytical protocols for single Raman spectrometers should be set up in order to get reliable CO2 density data. Kelemen, Peter B., & Craig E. Manning. PNAS, 112.30 (2015): E3997-E4006.Lamadrid, H. M., Moore, L. R., Moncada, D., Rimstidt, J. D., Burruss, R. C., & Bodnar, R. J. Chem. Geol. (2016).Rosso, K. M., & Bodnar, R. J. Geochim. et Cosmochim. Acta, 59(19), 3961-3975 (1995).
Spectral analysis of allogeneic hydroxyapatite powders
NASA Astrophysics Data System (ADS)
Timchenko, P. E.; Timchenko, E. V.; Pisareva, E. V.; Vlasov, M. Yu; Red'kin, N. A.; Frolov, O. O.
2017-01-01
In this paper we discuss the application of Raman spectroscopy to the in vitro analysis of the hydroxyapatite powder samples produced from different types of animal bone tissue during demineralization process at various acid concentrations and exposure durations. The derivation of the Raman spectrum of hydroxyapatite is attempted by the analysis of the pure powders of its known constituents. Were experimentally found spectral features of hydroxyapatite, based on analysis of the line amplitude at wave numbers 950-965 cm-1 ((PO4)3- (ν1) vibration) and 1065-1075 cm-1 ((CO3)2-(ν1) B-type replacement). Control of physicochemical properties of hydroxyapatite was carried out by Raman spectroscopy. Research results are compared with an infrared Fourier spectroscopy.
Synthesis of nanocrystalline diamonds by microwave plasma
NASA Astrophysics Data System (ADS)
Purohit, V. S.; Jain, Deepti; Sathe, V. G.; Ganesan, V.; Bhoraskar, S. V.
2007-03-01
Nanocrystalline diamonds, varying in size from 40 to 400 nm, with random faceting were grown without the help of initial nucleation sites on nickel substrates as seen by scanning electron micrographs. These carbonaceous films were deposited in a microwave plasma reactor using hexane/nitrogen based chemical vapour deposition. The substrate temperatures during deposition were varied from 400 to 600 °C. The morphological investigations obtained by scanning electron micrographs and atomic force microscopy revealed the presence of nanocrystallites with multifaceted structures. Micro Raman investigations were carried out on the deposited films, which conclusively inferred that the growth of nanodiamond crystallites seen in the scanning electron micrographs correlate with clear Raman peaks appearing at 1120 and 1140 cm-1. Nanoindentation analysis with atomic force microscopy has revealed that the carbonaceous deposition identified by the Raman line at ~1140 cm-1, in fact, is related to nanodiamond on account of its hardness which was ~30 GPa. X-ray diffraction data supported this fact.
NASA Astrophysics Data System (ADS)
Alvarez, J.; Boutchich, M.; Kleider, J. P.; Teraji, T.; Koide, Y.
2014-09-01
The origin of the high leakage current measured in several vertical-type diamond Schottky devices is conjointly investigated by conducting probe atomic force microscopy and confocal micro-Raman/photoluminescence imaging analysis. Local areas characterized by a strong decrease of the local resistance (5-6 orders of magnitude drop) with respect to their close surrounding have been identified in several different regions of the sample surface. The same local areas, also referenced as electrical hot-spots, reveal a slightly constrained diamond lattice and three dominant Raman bands in the low-wavenumber region (590, 914 and 1040 cm-1). These latter bands are usually assigned to the vibrational modes involving boron impurities and its possible complexes that can electrically act as traps for charge carriers. Local current-voltage measurements performed at the hot-spots point out a trap-filled-limited current as the main conduction mechanism favouring the leakage current in the Schottky devices.
Lin, Yu-Chung; Tsai, Lin-Wei; Perevedentseva, Elena; Chang, Hsin-Hou; Lin, Ching-Hui; Sun, Der-Shan; Lugovtsov, Andrei E; Priezzhev, Alexander; Mona, Jani; Cheng, Chia-Liang
2012-10-01
Nanodiamond has been proven to be biocompatible and proposed for various biomedical applications. Recently, nanometer-sized diamonds have been demonstrated as an effective Raman/fluorescence probe for bio-labeling, as well as, for drug delivery. Bio-labeling/drug delivery can be extended to the human blood system, provided one understands the interaction between nanodiamonds and the blood system. Here, the interaction of nanodiamonds (5 and 100 nm) with human red blood cells (RBC) in vitro is discussed. Measurements have been facilitated using Raman spectroscopy, laser scanning fluorescence spectroscopy, and laser diffractometry (ektacytometry). Data on cell viability and hemolytic analysis are also presented. Results indicate that the nanodiamonds in the studied condition do not cause hemolysis, and the cell viability is not affected. Importantly, the oxygenation/deoxygenation process was not found to be altered when nanodiamonds interacted with the RBC. However, the nanodiamond can affect some RBC properties such as deformability and aggregation in a concentration dependent manner. These results suggest that the nanodiamond can be used as an effective bio-labeling and drug delivery tool in ambient conditions, without complicating the blood's physiological conditions. However, controlling the blood properties including deformability of RBCs and rheological properties of blood is necessary during treatment.
Laser-generated bismuth nanoparticles for applications in imaging and radiotherapy
NASA Astrophysics Data System (ADS)
Torrisi, L.; Silipigni, L.; Restuccia, N.; Cuzzocrea, S.; Cutroneo, M.; Barreca, F.; Fazio, B.; Di Marco, G.; Guglielmino, S.
2018-08-01
Bismuth nanoparticles were obtained by laser ablation in water and characterized by using different physical techniques. Their shape, estimated by SEM measurements, was approximately spherical with an average diameter of about 25 nm, and a solution concentration of about 0.8 mg/ml was prepared. The formation of pure Bi nanoparticles was also confirmed by micro-Raman spectra which showed the characteristic first order Raman modes of rhombohedral bismuth. The presence of this phase was also supported by the XRD pattern. The EDX analysis indicated that the as-prepared nanoparticles contained Bi metallic element. The high Z of the nanoparticles in the solution shows effects of surface plasmon resonance in the near ultraviolet and visible regions, high mass absorption coefficient for X-ray interaction and high electronic and nuclear stopping powers for electron and ion beams. Such biocompatible solution can be injected in living systems, such as mice, in order to study the presence of uptake in different organs with high contrast spatial localization in the tissues where Bi nanoparticles are confined. The results indicate that Bi nanoparticles can be employed as high contrast medium for high resolution imaging in biological systems as well as target for exposition to ionizing radiation during radiotherapy or to visible light during hyperthermia of diseased cells.
Combined Raman spectroscopy and autofluoresence imaging method for in vivo skin tumor diagnosis
NASA Astrophysics Data System (ADS)
Zakharov, V. P.; Bratchenko, I. A.; Myakinin, O. O.; Artemyev, D. N.; Khristoforova, Y. A.; Kozlov, S. V.; Moryatov, A. A.
2014-09-01
The fluorescence and Raman spectroscopy (RS) combined method of in vivo detection of malignant human skin cancer was demonstrated. The fluorescence analysis was used for detection of abnormalities during fast scanning of large tissue areas. In suspected cases of malignancy the Raman spectrum analysis of biological tissue was performed to determine the type of neoplasm. A special RS phase method was proposed for in vivo identification of skin tumor. Quadratic Discriminant Analysis was used for tumor type classification on phase planes. It was shown that the application of phase method provides a diagnosis of malignant melanoma with a sensitivity of 89% and a specificity of 87%.
[Application of in situ cryogenic Raman spectroscopy to analysis of fluid inclusions in reservoirs].
Chen, Yong; Lin, Cheng-yan; Yu, Wen-quan; Zheng, Jie; Wang, Ai-guo
2010-01-01
Identification of salts is a principal problem for analysis of fluid inclusions in reservoirs. The fluid inclusions from deep natural gas reservoirs in Minfeng sub-sag were analyzed by in situ cryogenic Raman spectroscopy. The type of fluid inclusions was identified by Raman spectroscopy at room temperature. The Raman spectra show that the inclusions contain methane-bearing brine aqueous liquids. The fluid inclusions were analyzed at -180 degrees C by in situ cryogenic Raman spectroscopy. The spectra show that inclusions contain three salts, namely NaCl2, CaCl2 and MgCl2. Sodium chloride is most salt component, coexisting with small calcium chloride and little magnesium chloride. The origin of fluids in inclusions was explained by analysis of the process of sedimentation and diagenesis. The mechanism of diagenesis in reservoirs was also given in this paper. The results of this study indicate that in situ cryogenic Raman spectroscopy is an available method to get the composition of fluid inclusions in reservoirs. Based on the analysis of fluid inclusions in reservoirs by in situ cryogenic Raman spectroscopy with combination of the history of sedimentation and diagenesis, the authors can give important evidence for the type and mechanism of diagenesis in reservoirs.
NASA Astrophysics Data System (ADS)
Singh, Savita; Singh, Alok; Sharma, Sudhir Kumar
2017-06-01
In this paper, an analytical modeling and prediction of tensile and flexural strength of three dimensional micro-scaled novel coconut shell powder (CSP) reinforced epoxy polymer composites have been reported. The novel CSP has a specific mixing ratio of different coconut shell particle size. A comparison is made between obtained experimental strength and modified Guth model. The result shows a strong evidence for non-validation of modified Guth model for strength prediction. Consequently, a constitutive modeled equation named Singh model has been developed to predict the tensile and flexural strength of this novel CSP reinforced epoxy composite. Moreover, high resolution Raman spectrum shows that 40 % CSP reinforced epoxy composite has high dielectric constant to become an alternative material for capacitance whereas fractured surface morphology revealed that a strong bonding between novel CSP and epoxy polymer for the application as light weight composite materials in engineering.
Temperature Dependence of Raman-Active In-Plane E2g Phonons in Layered Graphene and h-BN Flakes
NASA Astrophysics Data System (ADS)
Li, Xiaoli; Liu, Jian; Ding, Kai; Zhao, Xiaohui; Li, Shuai; Zhou, Wenguang; Liang, Baolai
2018-01-01
Thermal properties of sp2 systems such as graphene and hexagonal boron nitride (h-BN) have attracted significant attention because of both systems being excellent thermal conductors. This research reports micro-Raman measurements on the in-plane E2g optical phonon peaks ( 1580 cm-1 in graphene layers and 1362 cm-1 in h-BN layers) as a function of temperature from - 194 to 200 °C. The h-BN flakes show higher sensitivity to temperature-dependent frequency shifts and broadenings than graphene flakes. Moreover, the thermal effect in the c direction on phonon frequency in h-BN layers is more sensitive than that in graphene layers but on phonon broadening in h-BN layers is similar as that in graphene layers. These results are very useful to understand the thermal properties and related physical mechanisms in h-BN and graphene flakes for applications of thermal devices.
Brauchle, Eva; Schenke-Layland, Katja
2013-01-01
Raman spectroscopy is an established laser-based technology for the quality assurance of pharmaceutical products. Over the past few years, Raman spectroscopy has become a powerful diagnostic tool in the life sciences. Raman spectra allow assessment of the overall molecular constitution of biological samples, based on specific signals from proteins, nucleic acids, lipids, carbohydrates, and inorganic crystals. Measurements are non-invasive and do not require sample processing, making Raman spectroscopy a reliable and robust method with numerous applications in biomedicine. Moreover, Raman spectroscopy allows the highly sensitive discrimination of bacteria. Rama spectra retain information on continuous metabolic processes and kinetics such as lipid storage and recombinant protein production. Raman spectra are specific for each cell type and provide additional information on cell viability, differentiation status, and tumorigenicity. In tissues, Raman spectroscopy can detect major extracellular matrix components and their secondary structures. Furthermore, the non-invasive characterization of healthy and pathological tissues as well as quality control and process monitoring of in vitro-engineered matrix is possible. This review provides comprehensive insight to the current progress in expanding the applicability of Raman spectroscopy for the characterization of living cells and tissues, and serves as a good reference point for those starting in the field. PMID:23161832
NASA Astrophysics Data System (ADS)
Li, Xiaowei; Xie, Qian; Jiang, Lan; Han, Weina; Wang, Qingsong; Wang, Andong; Hu, Jie; Lu, Yongfeng
2017-05-01
In this study, silicon micro/nanostructures of controlled size and shape are fabricated by chemical-etching-assisted femtosecond laser single-pulse irradiation, which is a flexible, high-throughput method. The pulse fluence is altered to create various laser printing patterns for the etching mask, resulting in the sequential evolution of three distinct surface micro/nanostructures, namely, ring-like microstructures, flat-top pillar microstructures, and spike nanostructures. The characterized diameter of micro/nanostructures reveals that they can be flexibly tuned from the micrometer (˜2 μm) to nanometer (˜313 nm) scales by varying the laser pulse fluence in a wide range. Micro-Raman spectroscopy and transmission electron microscopy are utilized to demonstrate that the phase state changes from single-crystalline silicon (c-Si) to amorphous silicon (a-Si) after single-pulse femtosecond laser irradiation. This amorphous layer with a lower etching rate then acts as a mask in the wet etching process. Meanwhile, the on-the-fly punching technique enables the efficient fabrication of large-area patterned surfaces on the centimeter scale. This study presents a highly efficient method of controllably manufacturing silicon micro/nanostructures with different single-pulse patterns, which has promising applications in the photonic, solar cell, and sensors fields.
SPECIATION OF ORGANICS IN WATER WITH RAMAN SPECTROSCOPY: UTILITY OF IONIC STRENGTH VARIATION
We have developed and are applying an experimental and mathematical method for describing the micro-speciation of complex organic contaminants in aqueous media. For our case, micro-speciation can be defined as qualitative and quantitative identification of all discrete forms of ...
Femtosecond laser microfabrication in polymers towards memory devices and microfluidic applications
NASA Astrophysics Data System (ADS)
Deepak, K. L. N.; Venugopal Rao, S.; Narayana Rao, D.
2011-12-01
We have investigated femtosecond laser induced microstructures, gratings, and craters in four different polymers: poly methyl methacrylate (PMMA), poly dimethyl siloxane (PDMS), polystyrene (PS) and poly vinyl alcohol (PVA) using Ti:sapphire laser delivering 800 nm, 100 femtosecond (fs) pulses at 1 kHz repetition rate with a maximum pulse energy of 1 mJ. Local chemical modifications leading to the formation of optical centers and peroxide radicals which were studied using UV-Visible absorption and emission, confocal micro-Raman and Electron Spin Resonance (ESR) spectroscopic techniques.
Composition of prehistoric rock-painting pigments from Egypt (Gilf Kébir area).
Darchuk, L; Rotondo, G Gatto; Swaenen, M; Worobiec, A; Tsybrii, Z; Makarovska, Y; Van Grieken, R
2011-12-01
The composition of rock-painting pigments from Egypt (Gilf Kebia area) has been analyzed by means of molecular spectroscopy such as Fourier transform infrared and micro-Raman spectroscopy and scanning electron microscopy coupled to an energy dispersive X-ray spectrometer and X-ray fluorescence analysis. Red and yellow pigments were recognized as red and yellow ochre with additional rutile. Copyright © 2011 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guseynov, R. R.; Tanriverdiyev, V. A.; Kipshidze, G., E-mail: gela.kishidze@stonybrook.ede
Unrelaxed InAs{sub 1–x}Sb{sub x} (x = 0.43 and 0.38) alloy layers are produced by molecular-beam epitaxy on compositionally graded GaInSb and AlGaInSb buffer layers. The high quality of the thin films produced is confirmed by the results of high-resolution X-ray diffraction analysis and micro-Raman studies. The twomode type of transformation of the phonon spectra of InAs{sub 1–x}Sb{sub x} alloys is established.
LWIR hyperspectral micro-imager for detection of trace explosive particles
NASA Astrophysics Data System (ADS)
Bingham, Adam L.; Lucey, Paul G.; Akagi, Jason T.; Hinrichs, John L.; Knobbe, Edward T.
2014-05-01
Chemical micro-imaging is a powerful tool for the detection and identification of analytes of interest against a cluttered background (i.e. trace explosive particles left behind in a fingerprint). While a variety of groups have demonstrated the efficacy of Raman instruments for these applications, point by point or line by line acquisition of a targeted field of view (FOV) is a time consuming process if it is to be accomplished with useful spatial resolutions. Spectrum Photonics has developed and demonstrated a prototype system utilizing long wave infrared hyperspectral microscopy, which enables the simultaneous collection of LWIR reflectance spectra from 8-14 μm in a 30 x 7 mm FOV with 30 μm spatial resolution in 30 s. An overview of the uncooled Sagnac-based LWIR HSM system will be given, emphasizing the benefits of this approach. Laboratory Hyperspectral data collected from custom mixtures and fingerprint residues is shown, focusing on the ability of the LWIR chemical micro-imager to detect chemicals of interest out of a cluttered background.
Structural Analysis of Hand Drawn Bumblebee Bombus terrestris Silk.
Woodhead, Andrea L; Sutherland, Tara D; Church, Jeffrey S
2016-07-20
Bombus terrestris, commonly known as the buff-tailed bumblebee, is native to Europe, parts of Africa and Asia. It is commercially bred for use as a pollinator of greenhouse crops. Larvae pupate within a silken cocoon that they construct from proteins produced in modified salivary glands. The amino acid composition and protein structure of hand drawn B. terrestris, silk fibres was investigated through the use of micro-Raman spectroscopy. Spectra were obtained from single fibres drawn from the larvae salivary gland at a rate of 0.14 cm/s. Raman spectroscopy enabled the identification of poly(alanine), poly(alanine-glycine), phenylalanine, tryptophan, and methionine, which is consistent with the results of amino acid analysis. The dominant protein conformation was found to be coiled coil (73%) while the β-sheet content of 10% is, as expected, lower than those reported for hornets and ants. Polarized Raman spectra revealed that the coiled coils were highly aligned along the fibre axis while the β-sheet and random coil components had their peptide carbonyl groups roughly perpendicular to the fibre axis. The protein orientation distribution is compared to those of other natural and recombinant silks. A structural model for the B. terrestris silk fibre is proposed based on these results.
Akkus, Anna; Yang, Shan; Roperto, Renato; Mustafa, Hathem; Teich, Sorin; Akkus, Ozan
2017-02-01
Measurement of tooth enamel mineralization using a clinically viable method is essential since variation of mineralization may be used to monitor caries risk or in assessing the effectiveness of remineralization therapy. Fiber optic Raman systems are becoming more affordable and popular in context of biomedical applications. However, the applicability of fiber optic Raman systems for measurement of mineral content within enamel tissue has not been elucidated significantly in the prior literature. Human teeth with varying degrees of enamel mineralization were selected. In addition alligator, boar and buffalo teeth which have increasing amount of mineral content, respectively, were also included as another set of samples. Reference Raman measurements of mineralization were performed using a high-fidelity confocal Raman microscope. Analysis of human teeth by research grade Raman system indicated a 2-fold difference in the Raman intensities of v1 symmetric-stretch bands of mineral-related phosphate bonds and 7-fold increase in mineral related Raman intensities of animal teeth. However, fiber optic system failed to resolve the differences in the mineralization of human teeth. These results indicate that the sampling volume of fiber optic systems extends to the underlying dentin and that confocal aperture modification is essential to limit the sampling volume to within the enamel. Further research efforts will focus on putting together portable Raman systems integrated with confocal fiber probe. Key words: Enamel, mineral content, raman spectroscopy.
In Situ Hot-Spot Assembly as a General Strategy for Probing Single Biomolecules.
Liu, Huiqiao; Li, Qiang; Li, Mingmin; Ma, Sisi; Liu, Dingbin
2017-05-02
Single-molecule detection using surface-enhanced Raman spectroscopy (SERS) has attracted increasing attention in chemical and biomedical analysis. However, it remains a major challenge to probe single biomolecules by means of SERS hot spots owing to the small volume of hot spots and their random distribution on substrates. We here report an in situ hot-spot assembly method as a general strategy for probing single biomolecules. As a proof-of-concept, this proposed strategy was successfully used for the detection of single microRNA-21 (miRNA-21, a potential cancer biomarker) at the single-cell level, showing great capability in differentiating the expression of miRNA-21 in single cancer cells from normal cells. This approach was further extended to single-protein detection. The versatility of the strategy opens an exciting avenue for single-molecule detection of biomarkers of interest and thus holds great promise in a variety of biological and biomedical applications.
Molybdenum oxide nanocolloids prepared by an external field-assisted laser ablation in water
NASA Astrophysics Data System (ADS)
Spadaro, Salvatore; Bonsignore, Martina; Fazio, Enza; Cimino, Francesco; Speciale, Antonio; Trombetta, Domenico; Barreca, Francesco; Saija, Antonina; Neri, Fortunato
2018-01-01
he synthesis of extremely stable molybdenum oxide nanocolloids by pulsed laser ablation was studied. This green technique ensures the formation of contaminant-free nanostructures and the absence of by-products. A focused picosecond pulsed laser beam was used to ablate a solid molybdenum target immersed in deionized water. Molybdenum oxide nearly spherical nanoparticles with dimensions within few nanometers (20-100 nm) are synthesized when the ablation processes were carried out, in water, at room temperature and 80°C. The application of an external electric field during the ablation process induces a nanostructures reorganization, as indicated by Scanning-Transmission Electron Microscopy images analysis. The ablation products were also characterized by some spectroscopic techniques: conventional UV-vis optical absorption, atomic absorption, dynamic light scattering, micro-Raman and X-ray photoelectron spectroscopies. Finally, NIH/3T3 mouse fibroblasts were used to evaluate cell viability by the sulforhodamine B assay
Industrial Raman gas sensing for real-time system control
NASA Astrophysics Data System (ADS)
Buric, M.; Mullen, J.; Chorpening, B.; Woodruff, S.
2014-06-01
Opportunities exist to improve on-line process control in energy applications with a fast, non-destructive measurement of gas composition. Here, we demonstrate a Raman sensing system which is capable of reporting the concentrations of numerous species simultaneously with sub-percent accuracy and sampling times below one-second for process control applications in energy or chemical production. The sensor is based upon a hollow-core capillary waveguide with a 300 micron bore with reflective thin-film metal and dielectric linings. The effect of using such a waveguide in a Raman process is to integrate Raman photons along the length of the sample-filled waveguide, thus permitting the acquisition of very large Raman signals for low-density gases in a short time. The resultant integrated Raman signals can then be used for quick and accurate analysis of a gaseous mixture. The sensor is currently being tested for energy applications such as coal gasification, turbine control, well-head monitoring for exploration or production, and non-conventional gas utilization. In conjunction with an ongoing commercialization effort, the researchers have recently completed two prototype instruments suitable for hazardous area operation and testing. Here, we report pre-commercialization testing of those field prototypes for control applications in gasification or similar processes. Results will be discussed with respect to accuracy, calibration requirements, gas sampling techniques, and possible control strategies of industrial significance.
Principal component analysis of bacteria using surface-enhanced Raman spectroscopy
NASA Astrophysics Data System (ADS)
Guicheteau, Jason; Christesen, Steven D.
2006-05-01
Surface-enhanced Raman scattering (SERS) provides rapid fingerprinting of biomaterial in a non-destructive manner. The problem of tissue fluorescence, which can overwhelm a normal Raman signal from biological samples, is largely overcome by treatment of biomaterials with colloidal silver. This work presents a study into the applicability of qualitative SER spectroscopy with principal component analysis (PCA) for the discrimination of four biological threat simulants; Bacillus globigii, Pantoea agglomerans, Brucella noetomae, and Yersinia rohdei. We also demonstrate differentiation of gram-negative and gram-positive species and as well as spores and vegetative cells of Bacillus globigii.
[Laser Raman Spectroscopy and Its Application in Gas Hydrate Studies].
Fu, Juan; Wu, Neng-you; Lu, Hai-long; Wu, Dai-dai; Su, Qiu-cheng
2015-11-01
Gas hydrates are important potential energy resources. Microstructural characterization of gas hydrate can provide information to study the mechanism of gas hydrate formation and to support the exploitation and application of gas hydrate technology. This article systemly introduces the basic principle of laser Raman spectroscopy and summarizes its application in gas hydrate studies. Based on Raman results, not only can the information about gas composition and structural type be deduced, but also the occupancies of large and small cages and even hydration number can be calculated from the relative intensities of Raman peaks. By using the in-situ analytical technology, laser Raman specstropy can be applied to characterize the formation and decomposition processes of gas hydrate at microscale, for example the enclathration and leaving of gas molecules into/from its cages, to monitor the changes in gas concentration and gas solubility during hydrate formation and decomposition, and to identify phase changes in the study system. Laser Raman in-situ analytical technology has also been used in determination of hydrate structure and understanding its changing process under the conditions of ultra high pressure. Deep-sea in-situ Raman spectrometer can be employed for the in-situ analysis of the structures of natural gas hydrate and their formation environment. Raman imaging technology can be applied to specify the characteristics of crystallization and gas distribution over hydrate surface. With the development of laser Raman technology and its combination with other instruments, it will become more powerful and play a more significant role in the microscopic study of gas hydrate.
Microcavity Enhanced Raman Scattering
NASA Astrophysics Data System (ADS)
Petrak, Benjamin J.
Raman scattering can accurately identify molecules by their intrinsic vibrational frequencies, but its notoriously weak scattering efficiency for gases presents a major obstacle to its practical application in gas sensing and analysis. This work explores the use of high finesse (≈50 000) Fabry-Perot microcavities as a means to enhance Raman scattering from gases. A recently demonstrated laser ablation method, which carves out a micromirror template on fused silica--either on a fiber tip or bulk substrates-- was implemented, characterized, and optimized to fabricate concave micromirror templates ˜10 mum diameter and radius of curvature. The fabricated templates were coated with a high-reflectivity dielectric coating by ion-beam sputtering and were assembled into microcavities ˜10 mum long and with a mode volume ˜100 mum 3. A novel gas sensing technique that we refer to as Purcell enhanced Raman scattering (PERS) was demonstrated using the assembled microcavities. PERS works by enhancing the pump laser's intensity through resonant recirculation at one longitudinal mode, while simultaneously, at a second mode at the Stokes frequency, the Purcell effect increases the rate of spontaneous Raman scattering by a change to the intra-cavity photon density of states. PERS was shown to enhance the rate of spontaneous Raman scattering by a factor of 107 compared to the same volume of sample gas in free space scattered into the same solid angle subtended by the cavity. PERS was also shown capable of resolving several Raman bands from different isotopes of CO2 gas for application to isotopic analysis. Finally, the use of the microcavity to enhance coherent anti-Stokes Raman scattering (CARS) from CO2 gas was demonstrated.
Chemical Mapping of Essential Oils, Flavonoids and Carotenoids in Citrus Peels by Raman Microscopy.
Yang, Ying; Wang, Xiaohe; Zhao, Chengying; Tian, Guifang; Zhang, Hua; Xiao, Hang; He, Lili; Zheng, Jinkai
2017-12-01
Citrus peels, by-products in large quantity, are rich in various functional and beneficial components which have wide applications. Chemical analysis of these components in citrus peels is an important step to determine the usefulness of the by-products for further applications. In this study, we explored Raman microscopy for rapid, nondestructive, and in situ chemical mapping of multiple main functional components from citrus peels. The relative amount and distribution in different locations (flavedo, albedo, and longitudinal section) of 3 main functional components (essential oils, carotenoids, and flavonoids) in citrus peels were systematically investigated. The distribution profiles of these components were heterogeneous on the peels and varied between different species of citrus peels. Essential oil was found mainly existed in the oil glands, while carotenoids were in the complementary location. Some flavonoids were observed in the oil glands. This study showed the capability of Raman microscopy for rapid and nondestructive analysis of multiple bio-components without extraction from plants. The information obtained from this study would assist the better production and application of the functional and beneficial components from citrus by products in an effective and sustainable manner. This study indicated the capability of Raman microscopy for rapid and nondestructive analysis of multiple bioactive components in plant tissues. The information obtained from the study would be valuable for developing effective and sustainable strategy of utilization of citrus peels for further applications. © 2017 Institute of Food Technologists®.
Nanostructure-based plasmon-enhanced Raman spectroscopy for surface analysis of materials
NASA Astrophysics Data System (ADS)
Ding, Song-Yuan; Yi, Jun; Li, Jian-Feng; Ren, Bin; Wu, De-Yin; Panneerselvam, Rajapandiyan; Tian, Zhong-Qun
2016-06-01
Since 2000, there has been an explosion of activity in the field of plasmon-enhanced Raman spectroscopy (PERS), including surface-enhanced Raman spectroscopy (SERS), tip-enhanced Raman spectroscopy (TERS) and shell-isolated nanoparticle-enhanced Raman spectroscopy (SHINERS). In this Review, we explore the mechanism of PERS and discuss PERS hotspots — nanoscale regions with a strongly enhanced local electromagnetic field — that allow trace-molecule detection, biomolecule analysis and surface characterization of various materials. In particular, we discuss a new generation of hotspots that are generated from hybrid structures combining PERS-active nanostructures and probe materials, which feature a strong local electromagnetic field on the surface of the probe material. Enhancement of surface Raman signals up to five orders of magnitude can be obtained from materials that are weakly SERS active or SERS inactive. We provide a detailed overview of future research directions in the field of PERS, focusing on new PERS-active nanomaterials and nanostructures and the broad application prospect for materials science and technology.
Formation of Si and Ge films and micropatterns by wet process using laser direct writing method
NASA Astrophysics Data System (ADS)
Watanabe, Akira
2011-03-01
The studies toward the formation of Si and Ge films and micropatterns by wet process using laser direct writing method are reported. First is the the formation of Si film by laser scanning irradiation to Si nano- or micro-particle dispersed films. By using organogermanium nanocluster (OrGe) as a dispersion medium of Si particles, a homogeneous Si film was formed by laser scanning irradiation on a Si particle/OrGe composite film. The micro-Raman spectra showed the formation of the polycrystalline Ge and SiGe alloy during the fusion of the Si particles by laser irradiation. The second is the formation of the Si and Ge micropatterns by LLDW (liquid phase laser direct writing) method. Micro-Raman spectra showed the formation of polycrystalline Si and Ge micropatterns by laser irradiation on the interfaces of SiCl4/substrate and GeCl4/substrate, respectively.
Raman Plus X: Biomedical Applications of Multimodal Raman Spectroscopy.
Das, Nandan K; Dai, Yichuan; Liu, Peng; Hu, Chuanzhen; Tong, Lieshu; Chen, Xiaoya; Smith, Zachary J
2017-07-07
Raman spectroscopy is a label-free method of obtaining detailed chemical information about samples. Its compatibility with living tissue makes it an attractive choice for biomedical analysis, yet its translation from a research tool to a clinical tool has been slow, hampered by fundamental Raman scattering issues such as long integration times and limited penetration depth. In this review we detail the how combining Raman spectroscopy with other techniques yields multimodal instruments that can help to surmount the translational barriers faced by Raman alone. We review Raman combined with several optical and non-optical methods, including fluorescence, elastic scattering, OCT, phase imaging, and mass spectrometry. In each section we highlight the power of each combination along with a brief history and presentation of representative results. Finally, we conclude with a perspective detailing both benefits and challenges for multimodal Raman measurements, and give thoughts on future directions in the field.
Raman Plus X: Biomedical Applications of Multimodal Raman Spectroscopy
Das, Nandan K.; Dai, Yichuan; Liu, Peng; Hu, Chuanzhen; Tong, Lieshu; Chen, Xiaoya
2017-01-01
Raman spectroscopy is a label-free method of obtaining detailed chemical information about samples. Its compatibility with living tissue makes it an attractive choice for biomedical analysis, yet its translation from a research tool to a clinical tool has been slow, hampered by fundamental Raman scattering issues such as long integration times and limited penetration depth. In this review we detail the how combining Raman spectroscopy with other techniques yields multimodal instruments that can help to surmount the translational barriers faced by Raman alone. We review Raman combined with several optical and non-optical methods, including fluorescence, elastic scattering, OCT, phase imaging, and mass spectrometry. In each section we highlight the power of each combination along with a brief history and presentation of representative results. Finally, we conclude with a perspective detailing both benefits and challenges for multimodal Raman measurements, and give thoughts on future directions in the field. PMID:28686212
Miernik, Arkadiusz; Eilers, Yvan; Bolwien, Carsten; Lambrecht, Armin; Hauschke, Dieter; Rebentisch, Gunter; Lossin, Phillipp S; Hesse, Albrecht; Rassweiler, Jens J; Wetterauer, Ulrich; Schoenthaler, Martin
2013-11-01
We evaluate a compact portable system for immediate automated postoperative ex vivo analysis of urinary stone composition using Raman spectroscopy. Analysis of urinary stone composition provides essential information for the treatment and metaphylaxis of urolithiasis. Currently infrared spectroscopy and x-ray diffraction are used for urinary stone analysis. However, these methods may require complex sample preparation and costly laboratory equipment. In contrast, Raman spectrometers could be a simple and quick strategy for immediate stone analysis. Pure samples of 9 stone components and 159 human urinary calculi were analyzed by Raman spectroscopy using a microscope coupled system at 2 excitation wavelengths. Signal-to-noise ratio, peak positions and the distinctness of the acquired Raman spectra were analyzed and compared. Background fluorescence was removed mathematically. Corrected Raman spectra were used as a reference library for automated classification of native human urinary stones (50). The results were then compared to standard infrared spectroscopy. Signal-to-noise ratio was superior at an excitation wavelength of 532 nm. An automated, computer based classifier was capable of matching spectra from patient samples with those of pure stone components. Consecutive analysis of 50 human stones demonstrated 100% sensitivity and specificity compared to infrared spectroscopy (for components with more than 25% of total composition). Our pilot study indicates that Raman spectroscopy is a valid and reliable technique for determining urinary stone composition. Thus, we propose that the development of a compact and portable system based on Raman spectroscopy for immediate, postoperative stone analysis could represent an invaluable tool for the metaphylaxis of urolithiasis. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.
Airborne chemistry: acoustic levitation in chemical analysis.
Santesson, Sabina; Nilsson, Staffan
2004-04-01
This review with 60 references describes a unique path to miniaturisation, that is, the use of acoustic levitation in analytical and bioanalytical chemistry applications. Levitation of small volumes of sample by means of a levitation technique can be used as a way to avoid solid walls around the sample, thus circumventing the main problem of miniaturisation, the unfavourable surface-to-volume ratio. Different techniques for sample levitation have been developed and improved. Of the levitation techniques described, acoustic or ultrasonic levitation fulfils all requirements for analytical chemistry applications. This technique has previously been used to study properties of molten materials and the equilibrium shape()and stability of liquid drops. Temperature and mass transfer in levitated drops have also been described, as have crystallisation and microgravity applications. The airborne analytical system described here is equipped with different and exchangeable remote detection systems. The levitated drops are normally in the 100 nL-2 microL volume range and additions to the levitated drop can be made in the pL-volume range. The use of levitated drops in analytical and bioanalytical chemistry offers several benefits. Several remote detection systems are compatible with acoustic levitation, including fluorescence imaging detection, right angle light scattering, Raman spectroscopy, and X-ray diffraction. Applications include liquid/liquid extractions, solvent exchange, analyte enrichment, single-cell analysis, cell-cell communication studies, precipitation screening of proteins to establish nucleation conditions, and crystallisation of proteins and pharmaceuticals.
NASA Astrophysics Data System (ADS)
Wu, Mingtao; Guo, Bing; Zhao, Qingliang; Fan, Rongwei; Dong, Zhiwei; Yu, Xin
2018-06-01
Micro-structured surface on diamond is widely used in microelectronics, optical elements, MEMS and NEMS components, ultra-precision machining tools, etc. The efficient micro-structuring of diamond material is still a challenging task. In this article, the influence of the focus position on laser machining and laser micro-structuring monocrystalline diamond surface were researched. At the beginning, the ablation threshold and its incubation effect of monocrystalline diamond were determined and discussed. As the accumulated laser pulses ranged from 40 to 5000, the laser ablation threshold decreased from 1.48 J/cm2 to 0.97 J/cm2. Subsequently, the variation of the ablation width and ablation depth in laser machining were studied. With enough pulse energy, the ablation width mainly depended on the laser propagation attributes while the ablation depth was a complex function of the focus position. Raman analysis was used to detect the variation of the laser machined diamond surface after the laser machining experiments. Graphite formation was discovered on the machined diamond surface and graphitization was enhanced after the defocusing quantity exceeded 45 μm. At last, several micro-structured surfaces were successfully fabricated on diamond surface with the defined micro-structure patterns and structuring ratios just by adjusting the defocusing quantity. The experimental structuring ratio was consistent with the theoretical analysis.
Bonetti, A; Bonifacio, A; Della Mora, A; Livi, U; Marchini, M; Ortolani, F
2015-04-20
Unlike its application for atherosclerotic plaque analysis, Raman microspectroscopy was sporadically used to check the sole nature of bioapatite deposits in stenotic aortic valves, neglecting the involvement of accumulated lipids/lipoproteins in the calcific process. Here, Raman microspectroscopy was employed for examination of stenotic aortic valve leaflets to add information on nature and distribution of accumulated lipids and their correlation with mineralization in the light of its potential precocious diagnostic use. Cryosections from surgically explanted stenotic aortic valves (n=4) were studied matching Raman maps against specific histological patterns. Raman maps revealed the presence of phospholipids/triglycerides and cholesterol, which showed spatial overlapping with one another and Raman-identified hydroxyapatite. Moreover, the Raman patterns correlated with those displayed by both von-Kossa-calcium- and Nile-blue-stained serial cryosections. Raman analysis also provided the first identification of carotenoids, which co-localized with the identified lipid moieties. Additional fit concerned the distribution of collagen and elastin. The good correlation of Raman maps with high-affinity staining patterns proved that Raman microspectroscopy is a reliable tool in evaluating calcification degree, alteration/displacement of extracellular matrix components, and accumulation rate of different lipid forms in calcified heart valves. In addition, the novel identification of carotenoids supports the concept that valve stenosis is an atherosclerosis-like valve lesion, consistently with their previous Raman microspectroscopical identification inside atherosclerotic plaques.
NASA Technical Reports Server (NTRS)
Chan, Q. H. S.; Zolensky, M.; Burton, A.; Clemett, S.; Fries, M.; Kebukawa, Y.
2015-01-01
At the 3rd International Announcement of Opportunity (AO), we have been approved for five Category 3 carbonaceous Itokawa particles (RA-QD02-0012, RA-QD02-0078, RB-CV-0029, RB-CV-0080 and RB-QD04-0052) recovered by the first Hayabusa mission of JAXA. In this investigation, we aim to provide a comprehensive study to characterize and account for the presence of carbon-bearing phases as suggested by the initial Scanning Electron Microscopy (SEM) analysis carried out by JAXA at the curation facility, and to describe the mineralogical components of the particles. The insoluble organic content of Itokawa particle has been investigated with the use of micro-Raman spectroscopy by Kitajima and co-workers [1]. The Raman spectra of Itokawa particles show broad G- and D-bands typical of low temperature material which offers an interesting contrast to the high metamorphic grade (LL4-6) of the Itokawa parent body. Amino acid analysis has been conducted by Naraoka et al. [2] to study the soluble organic component of Itokawa particles, but since it was a preliminary study and thus did not have the opportunity to target on Category 3 carbonaceous particles, only terrestrial contaminants were identified. The investigation will be carried out in the following order prioritized according to the progressive damage the analytical techniques can induce: (1) micro-Raman spectrometry, (2) two-step laser mass spectrometry (micro-L2MS), (3) ultra-high performance liquid chromatography with fluorescence detection and time-of-flight mass spectrometry (LC-FD/ToF-MS), and optimally if we can recover the particles after wet chemistry analysis, we will mount the samples and perform (4) electron beam microscopy (SEM, electron back-scattered diffraction [EBSD]) and (5) carbon X-ray absorption near edge structure spectroscopy (C-XANES). We will begin the analytical procedures upon receiving the samples in September/October. This work will provide us with an understanding of the variety and origins of the carbon-bearing phases present in primitive solar system bodies from a direct sample-returned mission, which is less likely hampered by risks of terrestrial contamination as compared to meteorite finds and falls.
Ivleva, Natalia P; Kubryk, Patrick; Niessner, Reinhard
2017-07-01
Biofilms represent the predominant form of microbial life on our planet. These aggregates of microorganisms, which are embedded in a matrix formed by extracellular polymeric substances, may colonize nearly all interfaces. Detailed knowledge of microorganisms enclosed in biofilms as well as of the chemical composition, structure, and functions of the complex biofilm matrix and their changes at different stages of the biofilm formation and under various physical and chemical conditions is relevant in different fields. Important research topics include the development and improvement of antibiotics and medical devices and the optimization of biocides, antifouling strategies, and biological wastewater treatment. Raman microspectroscopy is a capable and nondestructive tool that can provide detailed two-dimensional and three-dimensional chemical information about biofilm constituents with the spatial resolution of an optical microscope and without interference from water. However, the sensitivity of Raman microspectroscopy is rather limited, which hampers the applicability of Raman microspectroscopy especially at low biomass concentrations. Fortunately, the resonance Raman effect as well as surface-enhanced Raman scattering can help to overcome this drawback. Furthermore, the combination of Raman microspectroscopy with other microscopic techniques, mass spectrometry techniques, or particularly with stable-isotope techniques can provide comprehensive information on monospecies and multispecies biofilms. Here, an overview of different Raman microspectroscopic techniques, including resonance Raman microspectroscopy and surface-enhanced Raman scattering microspectroscopy, for in situ detection, visualization, identification, and chemical characterization of biofilms is given, and the main feasibilities and limitations of these techniques in biofilm research are presented. Future possibilities of and challenges for Raman microspectroscopy alone and in combination with other analytical techniques for characterization of complex biofilm matrices are discussed in a critical review. Graphical Abstract Applicability of Raman microspectroscopy for biofilm analysis.
[Micro-Raman and fluorescence spectra of several agrochemicals].
Xiao, Yi-lin; Zhang, Peng-xiang; Qian, Xiao-fan
2004-05-01
Raman and fluorescence spectra from several agrochemicals were measured, which are sold for the use in vegetables, fruits and grains. Characteristic vibration Raman peaks from some of the agrochemicals were recorded, hence the spectra can be used for their identification. Other marketed agrochemicals demonstrated strong fluorescence under 514.5 nm excitation. It was found that the fluorescence spectra of the agrochemicals are very different. According to these results one can detect the trace amount of agrochemicals left on the surface of fruits, vegetables and grains in situ and conveniently.
NASA Astrophysics Data System (ADS)
Ghosh, Subir; Choudhury, Dipankar; Roy, Taposh; Mamat, Azuddin Bin; Masjuki, H. H.; Pingguan-Murphy, Belinda
2015-06-01
Osteoarthritis-oriented synovial fluid (OASF), i.e., that typical of a patient with osteoarthritis, has different physical and biological characteristics than bovine serum (BS), a lubricant widely used in biotribological investigations. Micro-dimpled and diamond-like carbon- (DLC) coated surfaces are key emerging interfaces for orthopedic implants. In this study, tribological performances of dimpled surfaces, with and without DLC coating, have been investigated under both BS and OASF. The friction tests were performed utilizing a pin on a disk tribometer, whereas contact pressure, speed, and temperature were simulated to a ‘medium walking gait’ of hip joint conditions. The mechanical properties of the specimen and the physical properties of the lubricant were characterized before the friction test. Raman analysis was conducted to identify the coating condition both before and after the test. The DLC-coated dimpled surface showed maximum hardness and residual stress. A DLC-coated dimpled surface under an OASF lubricated condition yielded a lower friction coefficient and wear compared to those of plain and dimpled specimens. The higher graphitization of coated materials with increasing load was confirmed by Raman spectroscopy.
Ghosh, Subir; Choudhury, Dipankar; Roy, Taposh; Bin Mamat, Azuddin; Masjuki, H H; Pingguan-Murphy, Belinda
2015-01-01
Osteoarthritis-oriented synovial fluid (OASF), i.e., that typical of a patient with osteoarthritis, has different physical and biological characteristics than bovine serum (BS), a lubricant widely used in biotribological investigations. Micro-dimpled and diamond-like carbon- (DLC) coated surfaces are key emerging interfaces for orthopedic implants. In this study, tribological performances of dimpled surfaces, with and without DLC coating, have been investigated under both BS and OASF. The friction tests were performed utilizing a pin on a disk tribometer, whereas contact pressure, speed, and temperature were simulated to a ‘medium walking gait’ of hip joint conditions. The mechanical properties of the specimen and the physical properties of the lubricant were characterized before the friction test. Raman analysis was conducted to identify the coating condition both before and after the test. The DLC-coated dimpled surface showed maximum hardness and residual stress. A DLC-coated dimpled surface under an OASF lubricated condition yielded a lower friction coefficient and wear compared to those of plain and dimpled specimens. The higher graphitization of coated materials with increasing load was confirmed by Raman spectroscopy. PMID:27877803
NASA Astrophysics Data System (ADS)
Sulák, Marián; Kaindl, Reinhard; Putiš, Marián; Sitek, Jozef; Krenn, Kurt; Tóth, Ignác
2009-12-01
Potassium white micas in sheared basement and cover rocks from the Central Western Carpathians (CWC) were investigated by PL microscopy, electron microprobe (EMP) analysis, Mössbauer and micro-Raman spectroscopy. We specified chemical and spectroscopic characteristics, which allow distinction between celadonite-poor (muscovitic) and celadonite-rich (phengitic) white mica (Wmca). Wmca generations formed during a polystage evolution in changing P- T conditions ranging from the very low to medium temperatures at medium pressure within the Alpidic CWC orogenic wedge. BSE imaging, EMP analyses and X-ray element maps indicate chemical differences between muscovite and phengite, mainly in Al, Fe and Si contents. Mössbauer spectroscopy revealed their contrasting spectra, related to different hyperfine parameters, mainly of quadrupole splitting (QS of Ms: 2.6-2.7 mm/s, or 2.9-3.0 mm/s for Phg), corresponding to Fe 2+ and Fe 3+ contents. Blastomylonitic samples with a single dominating Wmca generation and finite-strain XZ sections were suitable for micro-Raman study. These data corroborate correlation between the frequencies of two vibrational modes of Wmca and Si content. The investigated Wmca generations indicate an enhanced transformation between Wmca phases in shear zones.
Sikirzhytski, Vitali; Sikirzhytskaya, Aliaksandra; Lednev, Igor K
2012-03-09
This proof-of-concept study demonstrated the potential of Raman microspectroscopy for nondestructive identification of traces of sweat for forensic purposes. Advanced statistical analysis of Raman spectra revealed that dry sweat was intrinsically heterogeneous, and its biochemical composition varies significantly with the donor. As a result, no single Raman spectrum could adequately represent sweat traces. Instead, a multidimensional spectroscopic signature of sweat was built that allowed for the presentation of any single experimental spectrum as a linear combination of two fluorescent backgrounds and three Raman spectral components dominated by the contribution from lactate, lactic acid, urea and single amino acids. Copyright © 2011 Elsevier B.V. All rights reserved.
Development of an optical fiber SERS microprobe for minimally invasive sensing applications
NASA Astrophysics Data System (ADS)
Mamun, Md Abdullah Al; Juodkazis, Saulius; Mahadevan-Jansen, Anita; Stoddart, Paul R.
2018-02-01
Numerous potential biomedical sensing applications of surface-enhanced Raman scattering (SERS) have been reported, but its practical use has been limited by the lack of a robust sensing platform. Optical fiber SERS probes show great promise, but are limited by the prominent silica Raman background, which requires the use of bulky optics for filtering the signal collection and excitation delivery paths. In the present study, a SERS microprobe has been designed and developed to eliminate the bottlenecks outlined above. For efficient excitation and delivery of the SERS signal, both hollow core photonic crystal fiber and double clad fiber have been investigated. While the hollow core fiber was still found to have excessive silica background, the double clad fiber allows efficient signal collection via the multi-mode inner cladding. A micro filtering mechanism has been designed, which can be integrated into the tip of the optical fiber SERS probe, providing filtering to suppress silica Raman background and thus avoiding the need for bulky optics. The design also assists in the efficient collection of SERS signal from the sample by rejecting Rayleigh scattered light from the sample. Optical fiber cleaving using ultra-short laser pulses was tested for improved control of the fiber tip geometry. With this miniaturized and integrated filtering mechanism, it is expected that the developed probe will promote the use of SERS for minimally invasive biomedical monitoring and sensing applications in future. The probe could potentially be placed inside a small gauge hypodermic needle and would be compatible with handheld portable spectrometers.
On the Contribution of Raman Spectroscopy to Forensic Science
NASA Astrophysics Data System (ADS)
Buzzini, Patrick; Massonnet, Genevieve
2010-08-01
Raman spectroscopy has only recently sparked interest from forensic laboratories. The Raman technique has demonstrated important advantages such as its nondestructive nature, its fast analysis time, and especially the possibility of performing microscopical in situ analyses. In forensic applications, it is a versatile technique that covers a wide spectrum of substances such as trace evidence, illicit drugs and inks. An overview of the recent developments of Raman spectroscopy in forensic science will be discussed. Also, the requirements for an analytical technique for the examination of physical evidence will be described. Examples of casework will be depicted.
Applications of Fourier transform Raman and infrared spectroscopy in forensic sciences
NASA Astrophysics Data System (ADS)
Kuptsov, Albert N.
2000-02-01
First in the world literature comprehensive digital complementary vibrational spectra collection of polymer materials and search system was developed. Non-destructive combined analysis using complementary FT-Raman and FTIR spectra followed by cross-parallel searching on digital spectral libraries, was applied in different fields of forensic sciences. Some unique possibilities of Raman spectroscopy has been shown in the fields of examination of questioned documents, paper, paints, polymer materials, gemstones and other physical evidences.
Emerging technology: applications of Raman spectroscopy for prostate cancer.
Kast, Rachel E; Tucker, Stephanie C; Killian, Kevin; Trexler, Micaela; Honn, Kenneth V; Auner, Gregory W
2014-09-01
There is a need in prostate cancer diagnostics and research for a label-free imaging methodology that is nondestructive, rapid, objective, and uninfluenced by water. Raman spectroscopy provides a molecular signature, which can be scaled from micron-level regions of interest in cells to macroscopic areas of tissue. It can be used for applications ranging from in vivo or in vitro diagnostics to basic science laboratory testing. This work describes the fundamentals of Raman spectroscopy and complementary techniques including surface enhanced Raman scattering, resonance Raman spectroscopy, coherent anti-Stokes Raman spectroscopy, confocal Raman spectroscopy, stimulated Raman scattering, and spatially offset Raman spectroscopy. Clinical applications of Raman spectroscopy to prostate cancer will be discussed, including screening, biopsy, margin assessment, and monitoring of treatment efficacy. Laboratory applications including cell identification, culture monitoring, therapeutics development, and live imaging of cellular processes are discussed. Potential future avenues of research are described, with emphasis on multiplexing Raman spectroscopy with other modalities.
Remote sensing capacity of Raman spectroscopy in identification of mineral and organic constituents
NASA Astrophysics Data System (ADS)
Chen, Bin; Stoker, Carol; Cabrol, Nathalie; McKay, Christopher P.
2007-09-01
We present design, integration and test results for a field Raman spectrometer science payload, integrated into the Mars Analog Research and Technology (MARTE) drilling platform. During the drilling operation, the subsurface Raman spectroscopy inspection system has obtained signatures of organic and mineral compositions. We also performed ground truth studies using both this field unit and a laboratory micro Raman spectrometer equipped with multiple laser excitation wavelengths on series of field samples including Mojave rocks, Laguna Verde salty sediment and Rio Tinto topsoil. We have evaluated laser excitation conditions and optical probe designs for further improvement. We have demonstrated promising potential for Raman spectroscopy as a non-destructive in situ, high throughput, subsurface detection technique, as well as a desirable active remote sensing tool for future planetary and space missions.
Mapping residual stress fields from Vickers hardness indents using Raman microprobe spectroscopy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sparks, R.G.; Enloe, W.S.; Paesler, M.A.
Micro-Raman spectroscopy is used to map the residual stress fields in the vicinity of Vickers hardness indents. Both 514.5 and 488.0 nm, light is used to excite the effect and the resulting shifted and broadened Raman peaks are analyzed using computer deconvolution. Half-wave plates are used to vary the orientation of the incident later light`s polarization state with respect to crystal orientation. The Raman scattered light is then analyzed for polarization dependences which are indicative of the various components of the Raman scattering tensor. Such studies can yield valuable information about the orientation of stress components in a well knownmore » stress field. The results can then be applied to the determination of stress components in machined semiconductor materials.« less
Borowicz, P.; Taube, A.; Rzodkiewicz, W.; Latek, M.; Gierałtowska, S.
2013-01-01
Three samples with dielectric layers from high-κ dielectrics, hafnium oxide, gadolinium-silicon oxide, and lanthanum-lutetium oxide on silicon substrate were studied by Raman spectroscopy. The results obtained for high-κ dielectrics were compared with spectra recorded for silicon dioxide. Raman spectra suggest the similarity of gadolinium-silicon oxide and lanthanum-lutetium oxide to the bulk nondensified silicon dioxide. The temperature treatment of hafnium oxide shows the evolution of the structure of this material. Raman spectra recorded for as-deposited hafnium oxide are similar to the results obtained for silicon dioxide layer. After thermal treatment especially at higher temperatures (600°C and above), the structure of hafnium oxide becomes similar to the bulk non-densified silicon dioxide. PMID:24072982
Münchberg, Ute; Wagner, Lysett; Spielberg, Eike T; Voigt, Kerstin; Rösch, Petra; Popp, Jürgen
2013-02-01
Zygomycetes are well known for their ability to produce various secondary metabolites. Fungi of the genus Mortierella can accumulate highly unsaturated lipids in large amounts as lipid droplets. However, no information about the spatial distribution or homogeneity of the oil inside the fungi is obtainable to date due to the invasive and destructive analytical techniques applied so far. Raman spectroscopy has been demonstrated to be well suited to investigate biological samples on a micrometre scale. It also has been shown that the degree of unsaturation of lipids can be determined from Raman spectra. We applied micro-Raman spectroscopy to investigate the spatial distribution and composition of lipid vesicles inside intact hyphae. For Mortierella alpina and Mortierella elongata distinct differences in the degree of unsaturation and even the impact of growth conditions are determined from the Raman spectra. In both species we found that the fatty acid saturation in the vesicles is highly variable in the first 600 μm of the growing hyphal tip and fluctuates towards a constant composition and saturation ratio in all of the remaining mycelium. Our approach facilitates in vivo monitoring of the lipid production and allows us to investigate the impact of cultivation parameters on the oil composition directly in the growing hyphae without the need for extensive extraction procedures. Copyright © 2012 Elsevier B.V. All rights reserved.
Application study of the optical biopsy system for small experimental animals
NASA Astrophysics Data System (ADS)
Sato, Hidetoshi; Suzuki, Toshiaki; Morita, Shin-ichi; Maruyama, Atsushi; Shimosegawa, Toru; Matsuura, Yuji; Kanai, Gen'ichi; Ura, Nobuo; Masutani, Koji; Ozaki, Yukihiro
2008-02-01
An optical biopsy system for small experimental animals has been developed. The system includes endoscope probe, portable probe and two kinds of miniaturized Raman probes. The micro Raman probe (MRP) is made of optical fibers and the ball lens hollow optical fiber Raman probe (BHRP) is made of hollow fiber. The former has large focal depth and suitable to measure average spectra of subsurface tissue. The latter has rather small focal depth and it is possible to control focal length by selecting ball lens attached at the probe head. It is suitable to survey materials at the fixed depth in the tissue. The system is applied to study various small animal cancer models, such as esophagus and stomach rat models and subcutaneous mouse models of pancreatic cancers. In the studies of subcutaneous tumor model mouse, it is suggested that protein conformational changes occur in the tumor tissue within few minutes after euthanasia of the mouse. No more change is observed for the following ten minutes. Any alterations in the molecular level are not observed in normal skin, muscle tissues. Since the change completes in such a short time, it is suggested that this phenomenon caused by termination of blood circulation.
Hot-phonon generation in THz quantum cascade lasers
NASA Astrophysics Data System (ADS)
Spagnolo, V.; Vitiello, M. S.; Scamarcio, G.; Williams, B. S.; Kumar, S.; Hu, Q.; Reno, J. L.
2007-12-01
Observation of non-equilibrium optical phonons population associated with electron transport in THz quantum cascade lasers is reported. The phonon occupation number was measured by using a combination of micro-probe photoluminescence and Stokes/Anti-Stokes Raman spectroscopy. Energy balance analysis allows us to estimate the phonon relaxation rate, that superlinearly increases with the electrical power in the range 1.5 W - 1.95 W, above laser threshold. This observation suggests the occurrence of stimulated emission of optical phonons.
NASA Astrophysics Data System (ADS)
Glushkov, S. M.; Panchishin, I. M.; Fadeev, V. V.
1989-04-01
The method of laser Raman spectroscopy was used to study heterophase water systems. The apparatus included an argon laser, an optical multichannel analyzer, and a microcomputer. The temperature dependences of the profiles of the valence (stretching) band in the Raman spectrum of liquid water between + 50 °C and - 7 °C and of polycrystalline ice Ih (from 0 to - 62 °C) were determined, as well as the spectral polarization characteristics of the Raman valence band. A method was developed for the determination of the partial concentrations of the H2O molecules in liquid and solid phases present as a mixture. An analysis was made of the errors of the method and the sources of these errors. Applications of the method to multiparameter problems in more complex water systems (for example, solutions of potassium iodide in water) were considered. Other potential practical applications of the method were discussed.
Ultralow-threshold microcavity Raman laser on a microelectronic chip.
Kippenberg, T J; Spillane, S M; Armani, D K; Vahala, K J
2004-06-01
Using ultrahigh-Q toroid microcavities on a chip, we demonstrate a monolithic microcavity Raman laser. Cavity photon lifetimes in excess of 100 ns combined with mode volumes typically of less than 1000 (microm)3 significantly reduce the threshold for stimulated Raman scattering. In conjunction with the high ideality of a tapered optical fiber coupling junction, stimulated Raman lasing is observed at an ultralow threshold (as low as 74 microW of fiber-launched power at 1550 nm) with high efficiency (up to 45% at the critical coupling point) in good agreement with theoretical modeling. Equally important, the wafer-scale nature of these devices should permit integration with other photonic, mechanical, or electrical functionality on a chip.
Infrared and Raman Microscopy in Cell Biology
Matthäus, Christian; Bird, Benjamin; Miljković, Miloš; Chernenko, Tatyana; Romeo, Melissa; Diem, Max
2009-01-01
This chapter presents novel microscopic methods to monitor cell biological processes of live or fixed cells without the use of any dye, stains, or other contrast agent. These methods are based on spectral techniques that detect inherent spectroscopic properties of biochemical constituents of cells, or parts thereof. Two different modalities have been developed for this task. One of them is infrared micro-spectroscopy, in which an average snapshot of a cell’s biochemical composition is collected at a spatial resolution of typically 25 mm. This technique, which is extremely sensitive and can collect such a snapshot in fractions of a second, is particularly suited for studying gross biochemical changes. The other technique, Raman microscopy (also known as Raman micro-spectroscopy), is ideally suited to study variations of cellular composition on the scale of subcellular organelles, since its spatial resolution is as good as that of fluorescence microscopy. Both techniques exhibit the fingerprint sensitivity of vibrational spectroscopy toward biochemical composition, and can be used to follow a variety of cellular processes. PMID:19118679
NASA Astrophysics Data System (ADS)
Liu, Cheng-hui; Boydston-White, Susie; Wang, Wubao; Sordillo, Laura A.; Shi, Lingyan; Weisberg, Arel; Tomaselli, Vincent P.; Sordillo, Peter P.; Alfano, Robert R.
2016-03-01
Resonance Raman (RR) spectroscopic technique has a high potential for label-free and in-situ detection of biomedical lesions in vivo. This study evaluates the ability of RR spectroscopy method as an optical histopathology tool to detect the atherosclerotic plaque states of abdominal aorta in vitro. This part demonstrates the RR spectral molecular fingerprint features from different sites of the atherosclerotic abdominal aortic wall tissues. Total 57 sites of five pieces aortic samples in intimal and adventitial wall from an autopsy specimen were examined using confocal micro Raman system of WITec 300R with excitation wavelength of 532nm. The preliminary RR spectral biomarkers of molecular fingerprints indicated that typical calcified atherosclerotic plaque (RR peak at 964cm-1) tissue; fibrolipid plaque (RR peaks at 1007, 1161, 1517 and 2888cm-1) tissue, lipid pool with the fatty precipitation cholesterol) with collagen type I (RR peaks at 864, 1452, 1658, 2888 and 2948cm-1) in the soft tissue were observed and investigated.
NASA Astrophysics Data System (ADS)
Guerra, M.; Carvalho, M. L.; Le Gac, A.; Manso, M.; Mortari, C.; Longelin, S.; Pessanha, S.
2016-03-01
The richly decorated foral charter attributed by D. Manuel I of Portugal, in 1515, to the village of Setubal, was studied using Energy Dispersive X-ray Fluorescence spectrometry and Raman micro-spectroscopy. An in situ characterization of the pigments used in the production of this masterpiece showed a very different pigment palette choice when compared to other similar Manueline charters. The red and green pigments are particularly puzzling, as the widely used mercury- and copper-based pigments, vermillion and malachite, respectively, were not found in the illuminated frontispiece. Instead, the cheaper lead-based pigment minium was used in the King's flag, while a mixture of copper sulfates was found for the green color, identified by means of micro-Raman spectroscopy. This result led to a new look at the conception that only one Royal workshop existed for the elaboration of Manueline foral charters.
NASA Astrophysics Data System (ADS)
Gentile, A.; Ruffino, F.; D'Andrea, C.; Gucciardi, P. G.; Reitano, R.; Grimaldi, M. G.
2016-06-01
Micrometric Au structures, presenting a dendritic nano-structure, have been fabricated on a Si-based substrate. The fabrication method involves the deposition of a thin Au film on the substrate and a high-temperature annealing (1100°C) using fast heating and cooling ramps. The thermal process produces the growth, from the substrate, of Si micro-pillars whose top surfaces, covered by a crystalline Au layer, present a nanodendritic morphology. In addition to the micro-pillars, the sample surface presents a complex structural and chemical composition including Si3N4 regions due to the silicon-nitrogen intermixing during the heating stage. By studying the kinetic processes at the Au-Si interface during the thermal treatment, we describe the stages involved in the micro-pillars growth, in the dendritic morphology development, and in the Au atoms entrapment at the top of the dendritic surfaces. Finally, we present the analyses of the optical and surface enhanced Raman scattering properties of the Au dendritic aggregates. We show, in particular, that: (1) the Au dendrites aggregates act as effective scattering elements for the electromagnetic radiation in the infrared spectral region; and (2) the higher surface area due to the branched dendritic structure is responsible for the improvement in the sensitivity of the surface enhanced Raman scattering activity.
Surface-enhanced Raman sensor for trace chemical detection in water
NASA Astrophysics Data System (ADS)
Lee, Vincent Y.; Farquharson, Stuart; Rainey, Petrie M.
1999-11-01
Surface-enhanced Raman spectroscopy (SERS) promises to be one of the most sensitive methods for chemical detection and in recent years SERS has been used for chemical, biochemical, environmental, and physiological applications. A variety of methods using various media (electrodes, colloids, and substrates) have been successfully developed to enhance Raman signals by six orders of magnitude and more. However, SERS has not become a routine analytical technique because these methods are unable to provide quantitative measurements. This is largely due to the inability to fabricate a sampling medium that provides reversible chemical adsorption, analysis-to-analysis reproducibility, unrestricted solution requirements (reagent concentration and pH) or sample phase (liquid or solid). In an effort to overcome these restrictions, we have developed metal-doped sol-gels to provide surface-enhancement of Raman scattering.
Wang, Jian; You, Jinglin; Wang, Min; Lu, Liming; Wan, Songming; Sobol, A A
2017-10-05
In-situ high temperature Raman spectroscopic (HTRS) technique in combination with density functional theory (DFT) analysis has been adopted to investigate the micro-structure of solid and molten A 2 W 2 O 7 (A=Li, Na, K). The [WO 6 ] octahedra were found to be connected to each other by corner and edge sharing in the crystalline Li 2 W 2 O 7 and K 2 W 2 O 7 compounds. In the crystal lattice of Na 2 W 2 O 7 , on the other hand, the [WO 4 ] tetrahedra and [WO 6 ] octahedra were found to coexist and paired by corner sharing. Although the structural diversity has clearly led to distinct Raman spectra of the crystalline A 2 W 2 O 7 compounds, the spectra of their melts tended to be analogous, showing the typical vibration modes of (W 2 O 7 ) 2- dimer. A mechanism was then proposed to explain the structure evolution occurring during the melting process of A 2 W 2 O 7 . The effect of A + cation on the Raman bands of (W 2 O 7 ) 2- dimer in molten A 2 W 2 O 7 has also been investigated. Both the wavenumber and full width at half-height (FWHH) of the characteristic band assigned to the symmetrical stretching vibration mode of WO nb (non-bridging oxygen) in (W 2 O 7 ) 2- were found to decrease in the sequence of Li + , Na + and K + , indicating the cation effect on the mean bond length and its distribution range of WO nb . In addition, the relative intensity of this band was also influenced by the cation and it was increased in the order of Li 2 W 2 O 7 , Na 2 W 2 O 7 and K 2 W 2 O 7 , which has been explained by the charge transfer process and confirmed by Mulliken overlap population analysis. Copyright © 2017 Elsevier B.V. All rights reserved.
Micro-spectroscopy on silicon wafers and solar cells
2011-01-01
Micro-Raman (μRS) and micro-photoluminescence spectroscopy (μPLS) are demonstrated as valuable characterization techniques for fundamental research on silicon as well as for technological issues in the photovoltaic production. We measure the quantitative carrier recombination lifetime and the doping density with submicron resolution by μPLS and μRS. μPLS utilizes the carrier diffusion from a point excitation source and μRS the hole density-dependent Fano resonances of the first order Raman peak. This is demonstrated on micro defects in multicrystalline silicon. In comparison with the stress measurement by μRS, these measurements reveal the influence of stress on the recombination activity of metal precipitates. This can be attributed to the strong stress dependence of the carrier mobility (piezoresistance) of silicon. With the aim of evaluating technological process steps, Fano resonances in μRS measurements are analyzed for the determination of the doping density and the carrier lifetime in selective emitters, laser fired doping structures, and back surface fields, while μPLS can show the micron-sized damage induced by the respective processes. PMID:21711723
Micro-FTIR Spectroscopy of Experimentally Shocked Basaltic Andesite (SP Flow, AZ)
NASA Astrophysics Data System (ADS)
Johnson, J. R.; Jaret, S.; Glotch, T. D.; Sims, M.
2017-12-01
As part of an ongoing systematic study of experimental shock transformations in plagioclase using micro-Raman and micro-FTIR thermal infrared hyperspectral imaging and point spectroscopy [1-7], we report new micro-FTIR results on experimentally shocked, fine-grained basaltic andesite from SP Flow (AZ). This sample has relatively high primary glass content and an average plagioclase composition of labradorite/bytownite. The powder propellant gun at the Johnson Space Center was used to conduct the original shock experiments at peak pressures from 15 to 60 GPa [6-8], from which <10 mm fragments were recovered. Polished thin sections were made from portions of these fragments, and micro-FTIR point spectra were collected from 400-4000 cm-1 (2.5-25 µm) using a spot size of 40 x 40 mm at 8 cm-1 spectral sampling. Micro-FTIR hyperspectral maps of thin sections were acquired using the same instrument equipped with a 16 pixel HgCdTe linear array detector to provide spectra between 7000 and 715 cm-1 (1.4-14.0 µm) at 25 µm/pixel and 8 cm-1 spectral sampling (see figure for color composite and band depth images from unshocked sample). Micro-FTIR results show that the unshocked sample is dominated by the glassy matrix (light green in the color composite), with contributions from plagioclase and pyroxene. Initial analyses suggest that the SP Flow samples become dominantly amorphous at relatively low shock pressures, reflective of the high primary glass content and consistent with macro-scale spectra from [7]. Results from additional shock pressures and Raman spectra will be presented at the conference. Future work will include (1) Raman and FTIR analyses of basalt from Grand Falls (AZ), which has minimal primary glass content and relatively higher calcic plagioclase than SP Flow; and (2) comparison of these basalts to results from shocked plagioclase and to similar analyses of naturally shocked samples from Ries and Lonar Craters. [1] Jaret, S. et al., 11th Internat. GeoRaman Conf., #5095, 2014; [2] Jaret, S., et al., LPSC # 2056, 2015; [3] Jaret, S., et al., LPSC #1530, 2016; [4] Jaret, S., et al., LPSC, abs. #2484, 2017; [5] Jaret, S., et al. GSA, abstract #267947, 2015; [6] Johnson, J., et al., Amer. Mineral., 88, 1575-1582, 2003; [7] Johnson, J., Icarus 221 359-364, 2012; [8] Johnson, J., et al., Amer. Mineral., 92, 1148-1157, 2007.
Rosasco, G.J.; Roedder, E.
1979-01-01
Rosasco et al. (1975), reported the first successful application of laser-excited Raman spectroscopy for the identification and nondestructive partial analysis of individual solid, liquid, and gaseous phases in selected fluid inclusions. We report here the results of the application of a new instrument, based on back-scattering, that eliminates many of the previous stringent sample limitations and hence greatly expands the range of applicability of Raman spectroscopy to fluid inclusions. Fluid inclusions in many porphyry copper deposits contain 5-10 ??m 'daughter' crystals thought to be anhydrite but too small for identification by the previous Raman technique. Using the new instrument, we have verified that such daughter crystals in quartz from Bingham, Utah, are anhydrite. They may form by leakage of hydrogen causing internal autooxidation of sulfide ion. Daughter crystals were also examined in apatite (Durango, Mexico) and emerald (Muzo, Colombia). Valid analyses of sulfur species in solution in small fluid inclusions from ore deposits would be valuable, but are generally impossible by conventional methods. We present a calibration procedure for analyses for SO42- in such inclusions from Bingham, Utah (12,000 ?? 4000 ppm) and Creede, Colo. (probably < 500 ppm). A fetid Brazilian quartz, originally thought to contain liquid H2S, is shown to contain only HS- in major amounts. ?? 1979.
NASA Astrophysics Data System (ADS)
Duarte, Janaina; Pacheco, Marcos T. T.; Silveira, Landulfo, Jr.; Machado, Rosangela Z.; Martins, Rodrigo A. L.; Zangaro, Renato A.; Villaverde, Antonio G. J. B.
2001-05-01
Near-infrared (NIR) Raman spectroscopy has been studied for the last years for many biomedical applications. It is a powerful tool for biological materials analysis. Toxoplasmosis is an important zoonosis in public health, cats being the principal responsible for the transmission of the disease in Brazil. The objective of this work is to investigate a new method of diagnosis of this disease. NIR Raman spectroscopy was used to detect anti Toxoplasma gondii antibodies in blood sera from domestic cats, without sample preparation. In all, six blood serum samples were used for this study. A previous serological test was done by the Indirect Immunoenzymatic Assay (ELISA) to permit a comparative study between both techniques and it showed that three serum samples were positive and the other three were negative to toxoplasmosis. Raman spectra were taken for all the samples and analyzed by using the principal components analysis (PCA). A diagnosis parameter was defined from the analysis of the second and third principal components of the Raman spectra. It was found that this parameter can detect the infection level of the animal. The results have indicated that NIR Raman spectroscopy, associated to the PCA can be a promising technique for serological analysis, such as toxoplasmosis, allowing a fast and sensitive method of diagnosis.
Salter, Robert; Chu, Johnny; Hippler, Michael
2012-10-21
A variant of cavity-enhanced Raman spectroscopy (CERS) is introduced, in which diode laser radiation at 635 nm is coupled into an external linear optical cavity composed of two highly reflective mirrors. Using optical feedback stabilisation, build-up of circulating laser power by 3 orders of magnitude occurs. Strong Raman signals are collected in forward scattering geometry. Gas phase CERS spectra of H(2), air, CH(4) and benzene are recorded to demonstrate the potential for analytical applications and fundamental molecular studies. Noise equivalent limits of detection in the ppm by volume range (1 bar sample) can be achieved with excellent linearity with a 10 mW excitation laser, with sensitivity increasing with laser power and integration time. The apparatus can be operated with battery powered components and can thus be very compact and portable. Possible applications include safety monitoring of hydrogen gas levels, isotope tracer studies (e.g., (14)N/(15)N ratios), observing isotopomers of hydrogen (e.g., radioactive tritium), and simultaneous multi-component gas analysis. CERS has the potential to become a standard method for sensitive gas phase Raman spectroscopy.
Analysis of human hair by Raman microspectroscopy
NASA Astrophysics Data System (ADS)
Plascencia-Castro, A. S.; Cordova-Fraga, T.; Piña-Ruiz, A. L.; Hernández-Rayas, A.; Bernal, J. J.
2017-04-01
Raman microspectroscopy is an optical compound identification technique, which is widely used nowadays for different field applications. A crucial part of this technique is the focus given to the sample in the microscope because it depends on which part of the sample it will analyze. In this work, the effects of irradiating a natural hair samples, obtained from women aged 18 to 55, with a monochromatic light of the Raman spectrometer in two different focus is presented. Two different spectra were obtained with a peak in common. Depending on the information wanted, how the sample is focused plays a crucial role, either way the spectra is information-rich and may be used for biomedical applications.
Narayanan, A Lakshmi; Dhamodaran, M; Solomon, J Samu; Karthikeyan, B; Govindhan, R
2018-02-01
Sensing ability of caffeine interaction with Phe-Phe annotates (PNTs), is presented (Govindhan et al., 2017; Karthikeyan et al., 2014; Tavagnacco et al., 2013; Kennedy et al., 2011; Wang et al., 2017) [1-5] in this data set. Investigation of synthesized caffeine carrying peptide nanotubes are carried out by FT-Raman spectral analysis and high resolution transmission electron microscopy (HR-TEM). Particle size of the caffeine loaded PNTs is < 40 nm. The FT-Raman spectrum signals are enhanced in the region of 400-1700 cm -1 . These data are ideal tool for the applications like biosensing and drug delivery research (DDS).
In Situ and In Vivo Molecular Analysis by Coherent Raman Scattering Microscopy
Liao, Chien-Sheng; Cheng, Ji-Xin
2017-01-01
Coherent Raman scattering (CRS) microscopy is a high-speed vibrational imaging platform with the ability to visualize the chemical content of a living specimen by using molecular vibrational fingerprints. We review technical advances and biological applications of CRS microscopy. The basic theory of CRS and the state-of-the-art instrumentation of a CRS microscope are presented. We further summarize and compare the algorithms that are used to separate the Raman signal from the nonresonant background, to denoise a CRS image, and to decompose a hyperspectral CRS image into concentration maps of principal components. Important applications of single-frequency and hyperspectral CRS microscopy are highlighted. Potential directions of CRS microscopy are discussed. PMID:27306307
Influence of the bracket on bonding and physical behavior of orthodontic resin cements.
Bolaños-Carmona, Victoria; Zein, Bilal; Menéndez-Núñez, Mario; Sánchez-Sánchez, Purificación; Ceballos-García, Laura; González-López, Santiago
2015-01-01
The aim of the study is to determine the influence of the type of bracket, on bond strength, microhardness and conversion degree (CD) of four resin orthodontic cements. Micro-tensile bond strength (µTBS) test between the bracket base and the cement was carried out on glass-hour-shaped specimens (n=20). Vickers Hardness Number (VHN) and micro-Raman spectra were recorded in situ under the bracket base. Weibull distribution, ANOVA and non-parametric test were applied for data analysis (p<0.05). The highest values of ή as well as the β Weibull parameter were obtained for metallic brackets with Transbond™ plastic brackets with the self-curing cement showing the worst performance. The CD was from 80% to 62.5%.
NASA Astrophysics Data System (ADS)
Kong, Kenny; Zaabar, Fazliyana; Rakha, Emad; Ellis, Ian; Koloydenko, Alexey; Notingher, Ioan
2014-10-01
Breast-conserving surgery (BCS) is increasingly employed for the treatment of early stage breast cancer. One of the key challenges in BCS is to ensure complete removal of the tumour while conserving as much healthy tissue as possible. In this study we have investigated the potential of Raman micro-spectroscopy (RMS) for automated intra-operative evaluation of tumour excision. First, a multivariate classification model based on Raman spectra of normal and malignant breast tissue samples was built and achieved diagnosis of mammary ductal carcinoma (DC) with 95.6% sensitivity and 96.2% specificity (5-fold cross-validation). The tumour regions were discriminated from the healthy tissue structures based on increased concentration of nucleic acids and reduced concentration of collagen and fat. The multivariate classification model was then applied to sections from fresh tissue of new patients to produce diagnosis images for DC. The diagnosis images obtained by raster scanning RMS were in agreement with the conventional histopathology diagnosis but were limited to long data acquisition times (typically 10 000 spectra mm-2, which is equivalent to ~5 h mm-2). Selective-sampling based on integrated auto-fluorescence imaging and Raman spectroscopy was used to reduce the number of Raman spectra to ~20 spectra mm-2, which is equivalent to an acquisition time of ~15 min for 5 × 5 mm2 tissue samples. This study suggests that selective-sampling Raman microscopy has the potential to provide a rapid and objective intra-operative method to detect mammary carcinoma in tissue and assess resection margins.
NASA Astrophysics Data System (ADS)
Larraona-Puy, M.; Ghita, A.; Zoladek, A.; Perkins, W.; Varma, S.; Leach, I. H.; Koloydenko, A. A.; Williams, H.; Notingher, I.
2011-05-01
Skin cancer is the most common human malignancy and basal cell carcinoma (BCC) represents approximately 80% of the non-melanoma cases. Current methods of treatment require histopathological evaluation of the tissues by qualified personnel. However, this method is subjective and in some cases BCC can be confused with other structures in healthy skin, including hair follicles. In this preliminary study, we investigated the potential of Raman micro-spectroscopy (RMS) to discriminate between hair follicles and BCC in skin tissue sections excised during Mohs micrographic surgery (MMS). Imaging and diagnosis of skin sections was automatically generated using ' a priori'-built spectral model based on LDA. This model had 90 ± 9% sensitivity and 85 ± 9% specificity for discrimination of BCC from dermis and epidermis. The model used selected Raman bands corresponding to the largest spectral differences between the Raman spectra of BCC and the normal skin regions, associated mainly with nucleic acids and collagen type I. Raman spectra corresponding to the epidermis regions of the hair follicles were found to be closer to those of healthy epidermis rather than BCC. Comparison between Raman spectral images and the gold standard haematoxylin and eosin (H&E) histopathology diagnosis showed good agreement. Some hair follicle regions were misclassified as BCC; regions corresponded mainly to the outermost layer of hair follicle (basal cells) which are expected to have higher nucleic acid concentration. This preliminary study shows the ability of RMS to distinguish between BCC and other tissue structures associated to healthy skin which can be confused with BCC due to their similar morphology.
Modulated Raman spectroscopy for enhanced identification of bladder tumor cells in urine samples.
Canetta, Elisabetta; Mazilu, Michael; De Luca, Anna Chiara; Carruthers, Antonia E; Dholakia, Kishan; Neilson, Sam; Sargeant, Harry; Briscoe, Tina; Herrington, C Simon; Riches, Andrew C
2011-03-01
Standard Raman spectroscopy (SRS) is a noninvasive technique that is used in the biomedical field to discriminate between normal and cancer cells. However, the presence of a strong fluorescence background detracts from the use of SRS in real-time clinical applications. Recently, we have reported a novel modulated Raman spectroscopy (MRS) technique to extract the Raman spectra from the background. In this paper, we present the first application of MRS to the identification of human urothelial cells (SV-HUC-1) and bladder cancer cells (MGH) in urine samples. These results are compared to those obtained by SRS. Classification using the principal component analysis clearly shows that MRS allows discrimination between Raman spectra of SV-HUC-1 and MGH cells with high sensitivity (98%) and specificity (95%). MRS is also used to distinguish between SV-HUC-1 and MGH cells after exposure to urine for up to 6 h. We observe a marked change in the MRS of SV-HUC-1 and MGH cells with time in urine, indicating that the conditions of sample collection will be important for the application of this methodology to clinical urine samples.
NASA Astrophysics Data System (ADS)
Abdallah, B.; Naddaf, M.; A-Kharroub, M.
2013-03-01
Non-stiochiometric zirconium nitride (ZrNx) thin films have been deposited on silicon substrates by vacuum arc discharge of (N2 + Ar) gas mixtures at different N2 partial pressure ratio. The microstructure, mechanical, electrical and wetting properties of these films are studied by means of X-ray diffraction (XRD), micro-Raman spectroscopy, Rutherford back scattering (RBS) technique, conventional micro-hardness testing, electrical resistivity, atomic force microscopy (AFM) and contact angle (CA) measurements. RBS results and analysis show that the (N/Zr) ratio in the film increases with increasing the N2 partial pressure. A ZrNx film with (Zr/N) ratio in the vicinity of stoichiometric ZrN is obtained at N2 partial pressure of 10%. XRD and Raman results indicate that all deposited films have strained cubic crystal phase of ZrN, regardless of the N2 partial pressure. On increasing the N2 partial pressure, the relative intensity of (1 1 1) orientation with respect to (2 0 0) orientation is seen to decrease. The effect of N2 partial pressure on micro-hardness and the resistivity of the deposited film is revealed and correlated to the alteration of grain size, crystallographic texture, stoichiometry and residual stress developed in the film. In particular, it is found that residual stress and nitrogen incorporation in the film play crucial role in the alteration of micro-hardness and resistivity respectively. In addition, CA and AFM results demonstrate that as N2 partial pressure increases, both the surface hydrophobicity and roughness of the deposited film increase, leading to a significant decrease in the film surface free energy (SFE).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bagnall, Kevin R.; Wang, Evelyn N.
2016-06-15
Micro-Raman thermography is one of the most popular techniques for measuring local temperature rise in gallium nitride (GaN) high electron mobility transistors with high spatial and temporal resolution. However, accurate temperature measurements based on changes in the Stokes peak positions of the GaN epitaxial layers require properly accounting for the stress and/or strain induced by the inverse piezoelectric effect. It is common practice to use the pinched OFF state as the unpowered reference for temperature measurements because the vertical electric field in the GaN buffer that induces inverse piezoelectric stress/strain is relatively independent of the gate bias. Although this approachmore » has yielded temperature measurements that agree with those derived from the Stokes/anti-Stokes ratio and thermal models, there has been significant difficulty in quantifying the mechanical state of the GaN buffer in the pinched OFF state from changes in the Raman spectra. In this paper, we review the experimental technique of micro-Raman thermography and derive expressions for the detailed dependence of the Raman peak positions on strain, stress, and electric field components in wurtzite GaN. We also use a combination of semiconductor device modeling and electro-mechanical modeling to predict the stress and strain induced by the inverse piezoelectric effect. Based on the insights gained from our electro-mechanical model and the best values of material properties in the literature, we analyze changes in the E{sub 2} high and A{sub 1} (LO) Raman peaks and demonstrate that there are major quantitative discrepancies between measured and modeled values of inverse piezoelectric stress and strain. We examine many of the hypotheses offered in the literature for these discrepancies but conclude that none of them satisfactorily resolves these discrepancies. Further research is needed to determine whether the electric field components could be affecting the phonon frequencies apart from the inverse piezoelectric effect in wurtzite GaN, which has been predicted theoretically in zinc blende gallium arsenide (GaAs).« less
Evaluating Lignocellulosic Biomass, Its Derivatives, and Downstream Products with Raman Spectroscopy
Lupoi, Jason S.; Gjersing, Erica; Davis, Mark F.
2015-01-01
The creation of fuels, chemicals, and materials from plants can aid in replacing products fabricated from non-renewable energy sources. Before using biomass in downstream applications, it must be characterized to assess chemical traits, such as cellulose, lignin, or lignin monomer content, or the sugars released following an acid or enzymatic hydrolysis. The measurement of these traits allows researchers to gage the recalcitrance of the plants and develop efficient deconstruction strategies to maximize yields. Standard methods for assessing biomass phenotypes often have experimental protocols that limit their use for screening sizeable numbers of plant species. Raman spectroscopy, a non-destructive, non-invasive vibrational spectroscopy technique, is capable of providing qualitative, structural information and quantitative measurements. Applications of Raman spectroscopy have aided in alleviating the constraints of standard methods by coupling spectral data with multivariate analysis to construct models capable of predicting analytes. Hydrolysis and fermentation products, such as glucose and ethanol, can be quantified off-, at-, or on-line. Raman imaging has enabled researchers to develop a visual understanding of reactions, such as different pretreatment strategies, in real-time, while also providing integral chemical information. This review provides an overview of what Raman spectroscopy is, and how it has been applied to the analysis of whole lignocellulosic biomass, its derivatives, and downstream process monitoring. PMID:25941674
Evaluating lignocellulosic biomass, its derivatives, and downstream products with Raman spectroscopy
Lupoi, Jason S.; Gjersing, Erica; Davis, Mark F.
2015-04-20
The creation of fuels, chemicals, and materials from plants can aid in replacing products fabricated from non-renewable energy sources. Before using biomass in downstream applications, it must be characterized to assess chemical traits, such as cellulose, lignin, or lignin monomer content, or the sugars released following an acid or enzymatic hydrolysis. The measurement of these traits allows researchers to gage the recalcitrance of the plants and develop efficient deconstruction strategies to maximize yields. Standard methods for assessing biomass phenotypes often have experimental protocols that limit their use for screening sizeable numbers of plant species. Raman spectroscopy, a non-destructive, non-invasive vibrationalmore » spectroscopy technique, is capable of providing qualitative, structural information and quantitative measurements. Applications of Raman spectroscopy have aided in alleviating the constraints of standard methods by coupling spectral data with multivariate analysis to construct models capable of predicting analytes. Hydrolysis and fermentation products, such as glucose and ethanol, can be quantified off-, at-, or on-line. Raman imaging has enabled researchers to develop a visual understanding of reactions, such as different pretreatment strategies, in real-time, while also providing integral chemical information. Finally, this review provides an overview of what Raman spectroscopy is, and how it has been applied to the analysis of whole lignocellulosic biomass, its derivatives, and downstream process monitoring.« less
NASA Astrophysics Data System (ADS)
West, Matthew J.; Went, Michael J.
2009-01-01
The application of powders to fingerprints has long been established as an effective and reliable method for developing latent fingerprints. Fingerprints developed in situ at a crime scene routinely undergo lifting with specialist tapes and are then stored in evidence bags to allow secure transit and also to preserve the chain of evidence. In a previous study we have shown that exogenous material within a fingerprint can be detected using Raman spectroscopy following development with powders and lifting with adhesive tapes. Other reports have detailed the use of Raman spectroscopy to the detection of drugs of abuse in latent fingerprints including cyanoacrylate-fumed fingerprints. This study involves the application of Raman spectroscopy for the analysis of drugs of abuse in latent fingerprints for fingerprints that had been treated with powders and also subsequently lifted with adhesive tapes. Samples of seized ecstasy, cocaine, ketamine and amphetamine were supplied by East Sussex Police and by the TICTAC unit at St. Georges Hospital Tooting. Contaminated fingerprints were deposited on clean glass slides. The application of aluminium or iron based powders to contaminated fingerprints did not interfere with the Raman spectra obtained for the contaminants. Contaminated fingerprints developed with powders and then lifted with lifting tapes were also examined. The combination of these two techniques did not interfere with the successful analysis. The lifting process was repeated using hinge lifters. As the hinge lifters exhibited strong Raman bands the spectroscopic analysis was more complex and an increase in the number of exposures to the detector allowed for improved clarification. Spectral subtraction was performed to remove peaks due to the hinge lifters using OMNIC software. Raman spectra of developed and lifted fingerprints recorded through evidence bags were obtained and it was found that the detection process was not compromised. Although the application of powders did not interfere with the detection process the time taken to locate the contaminant was increased due to the physical presence of more material within the fingerprint.
West, Matthew J; Went, Michael J
2009-01-01
The application of powders to fingerprints has long been established as an effective and reliable method for developing latent fingerprints. Fingerprints developed in situ at a crime scene routinely undergo lifting with specialist tapes and are then stored in evidence bags to allow secure transit and also to preserve the chain of evidence. In a previous study we have shown that exogenous material within a fingerprint can be detected using Raman spectroscopy following development with powders and lifting with adhesive tapes. Other reports have detailed the use of Raman spectroscopy to the detection of drugs of abuse in latent fingerprints including cyanoacrylate-fumed fingerprints. This study involves the application of Raman spectroscopy for the analysis of drugs of abuse in latent fingerprints for fingerprints that had been treated with powders and also subsequently lifted with adhesive tapes. Samples of seized ecstasy, cocaine, ketamine and amphetamine were supplied by East Sussex Police and by the TICTAC unit at St. Georges Hospital Tooting. Contaminated fingerprints were deposited on clean glass slides. The application of aluminium or iron based powders to contaminated fingerprints did not interfere with the Raman spectra obtained for the contaminants. Contaminated fingerprints developed with powders and then lifted with lifting tapes were also examined. The combination of these two techniques did not interfere with the successful analysis. The lifting process was repeated using hinge lifters. As the hinge lifters exhibited strong Raman bands the spectroscopic analysis was more complex and an increase in the number of exposures to the detector allowed for improved clarification. Spectral subtraction was performed to remove peaks due to the hinge lifters using OMNIC software. Raman spectra of developed and lifted fingerprints recorded through evidence bags were obtained and it was found that the detection process was not compromised. Although the application of powders did not interfere with the detection process the time taken to locate the contaminant was increased due to the physical presence of more material within the fingerprint.
Nondestructive Analysis of Astromaterials by Micro-CT and Micro-XRF Analysis for PET Examination
NASA Astrophysics Data System (ADS)
Zeigler, R. A.; Righter, K.; Allen, C. C.
2013-09-01
Here we discuss our recent investigations into the applications of micro-CT and micro-XRF analyses with Apollo samples and ANSMET meteorites and assess the usefulness of these techniques in future PET.
Bonetti, A.; Bonifacio, A.; Mora, A. Della; Livi, U.; Marchini, M.; Ortolani, F.
2015-01-01
Unlike its application for atherosclerotic plaque analysis, Raman microspectroscopy was sporadically used to check the sole nature of bioapatite deposits in stenotic aortic valves, neglecting the involvement of accumulated lipids/lipoproteins in the calcific process. Here, Raman microspectroscopy was employed for examination of stenotic aortic valve leaflets to add information on nature and distribution of accumulated lipids and their correlation with mineralization in the light of its potential precocious diagnostic use. Cryosections from surgically explanted stenotic aortic valves (n=4) were studied matching Raman maps against specific histological patterns. Raman maps revealed the presence of phospholipids/triglycerides and cholesterol, which showed spatial overlapping with one another and Raman-identified hydroxyapatite. Moreover, the Raman patterns correlated with those displayed by both von-Kossa-calcium- and Nile-blue-stained serial cryosections. Raman analysis also provided the first identification of carotenoids, which co-localized with the identified lipid moieties. Additional fit concerned the distribution of collagen and elastin. The good correlation of Raman maps with high-affinity staining patterns proved that Raman microspectroscopy is a reliable tool in evaluating calcification degree, alteration/displacement of extracellular matrix components, and accumulation rate of different lipid forms in calcified heart valves. In addition, the novel identification of carotenoids supports the concept that valve stenosis is an atherosclerosis-like valve lesion, consistently with their previous Raman microspectroscopical identification inside atherosclerotic plaques. PMID:26150160
Optical trapping and Raman spectroscopy of single nanostructures using standing-wave Raman tweezers
NASA Astrophysics Data System (ADS)
Wu, Mu-ying; He, Lin; Chen, Gui-hua; Yang, Guang; Li, Yong-qing
2017-08-01
Optical tweezers integrated with Raman spectroscopy allows analyzing a single trapped micro-particle, but is generally less effective for individual nano-sized objects in the 10-100 nm range. The main challenge is the weak gradient force on nanoparticles that is insufficient to overcome the destabilizing effect of scattering force and Brownian motion. Here, we present standing-wave Raman tweezers for stable trapping and sensitive characterization of single isolated nanostructures with a low laser power by combining a standing-wave optical trap (SWOT) with confocal Raman spectroscopy. This scheme has stronger intensity gradients and balanced scattering forces, and thus is more stable and sensitive in measuring nanoparticles in liquid with 4-8 fold increase in the Raman signals. It can be used to analyze many nanoparticles that cannot be measured with single-beam Raman tweezers, including individual single-walled carbon nanotubes (SWCNT), graphene flakes, biological particles, polystyrene beads (100 nm), SERS-active metal nanoparticles, and high-refractive semiconductor nanoparticles with a low laser power of a few milliwatts. This would enable sorting and characterization of specific SWCNTs and other nanoparticles based on their increased Raman fingerprints.
NASA Astrophysics Data System (ADS)
Sharma, S. K.; Misra, A. K.; Clegg, S. M.; Barefield, J. E.; Wiens, R. C.; Acosta, T.
2009-12-01
We have used a remote time-resolved (TR) telescopic Raman system equipped with 532 nm pulsed laser excitation and a gated intensified CCD (ICCD) detector for measuring Raman spectra of a number of minerals under two sets of conditions. The first set of experiments involved probing samples as a function of temperature ranging from 300 to 973 K at 1 atm. These experiments involve a 5x beam expander to focus the 532 nm (30 mJ/pulse 20 Hz) laser beams onto the sample at 9 m from the remote Raman system. The second set of experiments involved placing the samples in a high pressure vessel with a sapphire window containing supercritical CO2 at pressures up to 93 atm and 423 K. At high temperatures and ambient pressure, the remote Raman measurements were made with samples at 9 meter distance inside a high temperature furnace by gating the ICCD detector with 2 micro-s gate to minimize interference from blackbody emission from mineral surfaces at high temperature as well as interference from ambient light. A comparison of Raman spectra of gypsum (CaSO4.2H2O), dolomite (CaMg(CO3)2), and olivine (Mg2Fe2-xSiO4), as a function of temperature shows that the Raman lines remains sharp and well defined even in the high temperature spectra. In the pressure vessel, Cr3+ fluorescence from sapphire window interfere with the Raman spectra of hydrous minerals in the high-frequency region (2500-4500 cm-1). With time-resolved Raman measurements the interference of the fluorescence in the Raman spectra on minerals was minimized by gating ICCD to <100 ns. The Fermi resonance doublet of CO2 molecules consisting of Raman lines at 1285 (2ν2) and 1388 (ν1) cm-1 does not interfere with the major Raman fingerprints of silicates, carbonate, sulfates minerals. With suitable time delay of the ICCD detector, the Raman bands from supercritical CO2 atmosphere can be minimized providing pure Raman spectra of the mineral targets. We will present remote Raman data on silicates (olivine, pyroxene, quartz, feldspars and talc), dolomite, gypsum, hydrous iron sulfate and barite under supercritical CO2 environment. With TR remote Raman system using 532 nm (15 mJ/pulse, 20Hz) laser excitation, a large varieties of minerals could be easily identified from their respective Raman fingerprints typically in 1s. Minerals with low Raman cross section (e.g., feldspars, pyroxene, olivine, talc, etc) can be detected and quantified from their respective Raman spectra in 10 to 30 s. These results show that time-resolve remote Raman system is capable of making spectral measurements at several hundred to thousand target points on Venus surface within limited (a few hours) expected lifetime of a lander because of extreme temperature and pressure conditions.
NASA Astrophysics Data System (ADS)
Malherbe, C.; Hutchinson, I. B.; Ingley, R.; Boom, A.; Carr, A. S.; Edwards, H.; Vertruyen, B.; Gilbert, B.; Eppe, G.
2017-11-01
In 2020, the ESA ExoMars and NASA Mars 2020 missions will be launched to Mars to search for evidence of past and present life. In preparation for these missions, terrestrial analog samples of rock formations on Mars are studied in detail in order to optimize the scientific information that the analytical instrumentation will return. Desert varnishes are thin mineral coatings found on rocks in arid and semi-arid environments on Earth that are recognized as analog samples. During the formation of desert varnishes (which takes many hundreds of years), organic matter is incorporated, and microorganisms may also play an active role in the formation process. During this study, four complementary analytical techniques proposed for Mars missions (X-ray diffraction [XRD], Raman spectroscopy, elemental analysis, and pyrolysis-gas chromatography-mass spectrometry [Py-GC-MS]) were used to interrogate samples of desert varnish and describe their capacity to sustain life under extreme scenarios. For the first time, both the geochemistry and the organic compounds associated with desert varnish are described with the use of identical sets of samples. XRD and Raman spectroscopy measurements were used to nondestructively interrogate the mineralogy of the samples. In addition, the use of Raman spectroscopy instruments enabled the detection of β-carotene, a highly Raman-active biomarker. The content and the nature of the organic material in the samples were further investigated with elemental analysis and methylated Py-GC-MS, and a bacterial origin was determined to be likely. In the context of planetary exploration, we describe the habitable nature of desert varnish based on the biogeochemical composition of the samples. Possible interference of the geological substrate on the detectability of pyrolysis products is also suggested.
Nonlinear dynamic phase contrast microscopy for microfluidic and microbiological applications
NASA Astrophysics Data System (ADS)
Denz, C.; Holtmann, F.; Woerdemann, M.; Oevermann, M.
2008-08-01
In live sciences, the observation and analysis of moving living cells, molecular motors or motion of micro- and nano-objects is a current field of research. At the same time, microfluidic innovations are needed for biological and medical applications on a micro- and nano-scale. Conventional microscopy techniques are reaching considerable limits with respect to these issues. A promising approach for this challenge is nonlinear dynamic phase contrast microscopy. It is an alternative full field approach that allows to detect motion as well as phase changes of living unstained micro-objects in real-time, thereby being marker free, without contact and non destructive, i.e. fully biocompatible. The generality of this system allows it to be combined with several other microscope techniques such as conventional bright field or fluorescence microscopy. In this article we will present the dynamic phase contrast technique and its applications in analysis of micro organismic dynamics, micro flow velocimetry and micro-mixing analysis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Atanasov, Petar A., E-mail: paatanas@ie.bas.bg; Nedyalkov, Nikolay N.; Valova, Eugenia I.
We present an experimental analysis on surface structuring of polydimethylsiloxane films with UV (263 nm) femtosecond laser pulses, in air. Laser processed areas are analyzed by optical microscopy, SEM, and μ-Raman spectroscopy. The laser-treated sample shows the formation of a randomly nanostructured surface morphology. μ-Raman spectra, carried out at both 514 and 785 nm excitation wavelengths, prior and after laser treatment allow evidencing the changes in the sample structure. The influence of the laser fluence on the surface morphology is studied. Finally, successful electro-less metallization of the laser-processed sample is achieved, even after several months from the laser-treatment contrary to previous observationmore » with nanosecond pulses. Our findings address the effectiveness of fs-laser treatment and chemical metallization of polydimethylsiloxane films with perspective technological interest in micro-fabrication devices for MEMS and nano-electromechanical systems.« less
Effect of in situ Al doping on structure and optical properties of ZnO nanowires grown by MOCVD
NASA Astrophysics Data System (ADS)
Souissi, H.; Jabri, S.; Souissi, A.; Lusson, A.; Galtier, P.; Meftah, A.; Sallet, V.; Oueslati, M.
2018-01-01
Al-doped ZnO nanowires (NWs) were grown on C-axis oriented sapphire by metal organic chemical vapor deposition using dimethylzinc-triethylamine (DMZn-TEN), nitrogen dioxide (NO2) and TMAl as zinc, oxygen and aluminum doping sources respectively. The NWs morphology has been characterized by scanning electron microscopy and transmission electron microscopy. The photoluminescence (PL) spectra exhibit a strong excitonic transition bond that confirms the Al incorporation in the ZnO NWs. Raman results support PL conclusion by showing additional modes in Al-doped ZnO NWs at nearly 270, 510, 579 and 641 cm-1. The micro-Raman scattering analysis along a single Al-doped ZnO needle-like NW shows an increase of the Al concentration from the basis to the tip of the wire.
Raman Spectroscopy of Cocrystals
NASA Astrophysics Data System (ADS)
Rooney, Frank; Reardon, Paul; Ochoa, Romulo; Abourahma, Heba; Marti, Marcus; Dimeo, Rachel
2010-02-01
Cocrystals are a class of compounds that consist of two or more molecules that are held together by hydrogen bonding. Pharmaceutical cocrystals are those that contain an active pharmaceutical ingredient (API) as one of the components. Pharmaceutical cocrystals are of particular interest and have gained a lot of attention in recent years because they offer the ability to modify the physical properties of the API, like solubility and bioavailability, without altering the chemical structure of the API. The APIs that we targeted for our studies are theophylline (Tp) and indomethacin (Ind). These compounds have been mixed with complementary coformers (cocrystal former) that include acetamide (AcONH2), melamine (MLM), nicotinic acid (Nic-COOH), 4-cyanopyridine (4-CNPy) and 4-aminopyridine (4-NH2Py). Raman spectroscopy has been used to characterize these cocrystals. Spectra of the cocrystals were compared to those of the coformers to analyze for peak shifts, specifically those corresponding to hydrogen bonding. A 0.5 m CCD Spex spectrometer was used, in a micro-Raman setup, for spectral analysis. An Argon ion Coherent laser at 514.5 nm was used as the excitation source. )
Tamagnini, Francesco; Jeynes, J. Charles G.; Mattana, Sara; Swift, Imogen; Nallala, Jayakrupakar; Hancock, Jane; Brown, Jonathan T.; Randall, Andrew D.; Stone, Nick
2018-01-01
Recent work using micro-Fourier transform infrared (μFTIR) imaging has revealed that a lipid-rich layer surrounds many plaques in post-mortem Alzheimer's brain. However, the origin of this lipid layer is not known, nor is its role in the pathogenesis of Alzheimer's disease (AD). Here, we studied the biochemistry of plaques in situ using a model of AD. We combined FTIR, Raman and immunofluorescence images, showing that astrocyte processes co-localise with the lipid ring surrounding many plaques. We used μFTIR imaging to rapidly measure chemical signatures of plaques over large fields of view, and selected plaques for higher resolution analysis with Raman microscopy. Raman maps showed similar lipid rings and dense protein cores as in FTIR images, but also revealed cell bodies. We confirmed the presence of plaques using amylo-glo staining, and detected astrocytes using immunohistochemistry, revealing astrocyte co-localisation with lipid rings. This work is important because it correlates biochemical changes surrounding the plaque with the biological process of astrogliosis. PMID:29230441
Confocal mapping of myelin figures with micro-Raman spectroscopy
NASA Astrophysics Data System (ADS)
Huang, Jung-Ren; Cheng, Yu-Che; Huang, Hung Ji; Chiang, Hai-Pang
2018-01-01
We employ confocal micro-Raman spectroscopy (CMRS) with submicron spatial resolution to study the myelin structures (cylindrical lamellae) composed of nested surfactant C12E3 or lipid DMPC bilayers. The CMRS mapping indicates that for a straight C12E3 myelin, the surfactant concentration increases with the myelin width and is higher in the center region than in the peripheral region. For a curved C12E3 myelin, the convex side has a higher surfactant concentration than the corresponding concave side. The spectrum of DMPC myelins undergoes a qualitative change as the temperature increases above 60 °C, suggesting that the surfactant molecules may be damaged. Our work demonstrates the utility of CMRS in bio-soft material research.
Khun, N W; Liu, E
2011-06-01
Nitrogen doped diamond-like carbon (DLC:N) thin films were deposited on highly conductive p-Si substrates using a DC magnetron sputtering deposition system. The DLC:N films were characterized using X-ray photoelectron spectroscopy (XPS), micro-Raman spectroscopy, atomic force microscopy (AFM), contact angle measurement and micro-scratch test. The XPS and Raman results indicated that the sputtering power significantly influenced the properties of the films in terms of bonding configuration in the films. The corrosion performance of the DLC:N films was investigated in a 0.6 M NaCl solution by means of potentiodynamic polarization testing. It was found that the corrosion performance of the films could be enhanced by higher sputtering powers.
Brozek-Pluska, Beata; Kopec, Monika; Niedzwiecka, Izabela; Morawiec-Sztandera, Alina
2015-04-07
The applications of optical spectroscopic methods in cancer detection open new possibilities in oncological diagnostics. Raman spectroscopy and Raman imaging represent noninvasive, label-free, and rapidly developing tools in cancer diagnosis. In the study described in this paper Raman microspectroscopy has been employed to examine noncancerous and cancerous human salivary gland tissues of the same patient. The most significant differences between noncancerous and cancerous tissues were found in regions typical for the vibrations of lipids and proteins. The detailed analysis of secondary structures of proteins contained in the cancerous and the noncancerous tissues is also presented.
Identification of microplastics using Raman spectroscopy: Latest developments and future prospects.
Araujo, Catarina F; Nolasco, Mariela M; Ribeiro, Antonio M P; Ribeiro-Claro, Paulo J A
2018-06-06
Widespread microplastic pollution is raising growing concerns as to its detrimental effects upon living organisms. A realistic risk assessment must stand on representative data on the abundance, size distribution and chemical composition of microplastics. Raman microscopy is an indispensable tool for the analysis of very small microplastics (<20 μm). Still, its use is far from widespread, in part due to drawbacks such as long measurement time and proneness to spectral distortion induced by fluorescence. This review discusses each drawback followed by a showcase of interesting and easily available solutions that contribute to faster and better identification of microplastics using Raman spectroscopy. Among discussed topics are: enhanced signal quality with better detectors and spectrum processing; automated particle selection for faster Raman mapping; comprehensive reference libraries for successful spectral matching. A last section introduces non-conventional Raman techniques (non-linear Raman, hyperspectral imaging, standoff Raman) which permit more advanced applications such as real-time Raman detection and imaging of microplastics. Copyright © 2018 Elsevier Ltd. All rights reserved.
Leon-Bejarano, Maritza; Dorantes-Mendez, Guadalupe; Ramirez-Elias, Miguel; Mendez, Martin O; Alba, Alfonso; Rodriguez-Leyva, Ildefonso; Jimenez, M
2016-08-01
Raman spectroscopy of biological tissue presents fluorescence background, an undesirable effect that generates false Raman intensities. This paper proposes the application of the Empirical Mode Decomposition (EMD) method to baseline correction. EMD is a suitable approach since it is an adaptive signal processing method for nonlinear and non-stationary signal analysis that does not require parameters selection such as polynomial methods. EMD performance was assessed through synthetic Raman spectra with different signal to noise ratio (SNR). The correlation coefficient between synthetic Raman spectra and the recovered one after EMD denoising was higher than 0.92. Additionally, twenty Raman spectra from skin were used to evaluate EMD performance and the results were compared with Vancouver Raman algorithm (VRA). The comparison resulted in a mean square error (MSE) of 0.001554. High correlation coefficient using synthetic spectra and low MSE in the comparison between EMD and VRA suggest that EMD could be an effective method to remove fluorescence background in biological Raman spectra.
Application and Miniaturization of Linear and Nonlinear Raman Microscopy for Biomedical Imaging
NASA Astrophysics Data System (ADS)
Mittal, Richa
Current diagnostics for several disorders rely on surgical biopsy or evaluation of ex vivo bodily fluids, which have numerous drawbacks. We evaluated the potential for vibrational techniques (both linear and nonlinear Raman) as a reliable and noninvasive diagnostic tool. Raman spectroscopy is an optical technique for molecular analysis that has been used extensively in various biomedical applications. Based on demonstrated capabilities of Raman spectroscopy we evaluated the potential of the technique for providing a noninvasive diagnosis of mucopolysaccharidosis (MPS). These studies show that Raman spectroscopy can detect subtle changes in tissue biochemistry. In applications where sub-micrometer visualization of tissue compositional change is required, a transition from spectroscopy to high quality imaging is necessary. Nonlinear vibrational microscopy is sensitive to the same molecular vibrations as linear Raman, but features fast imaging capabilities. Coherent Raman scattering when combined with other nonlinear optical (NLO) techniques (like two-photon excited fluorescence and second harmonic generation) forms a collection of advanced optical techniques that provide noninvasive chemical contrast at submicron resolution. This capability to examine tissues without external molecular agents is driving the NLO approach towards clinical applications. However, the unique imaging capabilities of NLO microscopy are accompanied by complex instrument requirements. Clinical examination requires portable imaging systems for rapid inspection of tissues. Optical components utilized in NLO microscopy would then need substantial miniaturization and optimization to enable in vivo use. The challenges in designing compact microscope objective lenses and laser beam scanning mechanisms are discussed. The development of multimodal NLO probes for imaging oral cavity tissue is presented. Our prototype has been examined for ex vivo tissue imaging based on intrinsic fluorescence and SHG contrast. These studies show a potential for multiphoton compact probes to be used for real time imaging in the clinic.
Effect of precursors condition on the structural morphology of synthesized GaN
NASA Astrophysics Data System (ADS)
Muzammil, P.; Basha, S. Munawar; Muhammad, G. Shakil
2018-05-01
GaN nanostructures were synthesized using different mole concentration of precursor composing of gallium nitrate and PVP by sol-gel method. The structural analysis using X-ray diffraction shows the wurtzite form of GaN nanostructure, also it observed that the concentration of precursor play a vital role in structural quality as FWHM increase for higher concentration. From the SEM image it observed that for 0.25 and 0.5 M concentration the honey bee and nanorod structure were obtained. The micro-Raman analysis shows a strong E2H peak of GaN nanostructure.
Through-barrier detection of explosive components for security screening applications
NASA Astrophysics Data System (ADS)
Lee, Linda; Frisby, Alex; Mansson, Ralph; Hopkins, Rebecca J.
2011-11-01
The detection of materials through containers is a vital capability for security screening applications at high risk locations, such as airports and checkpoints. Current detection procedures require suspect containers to be opened and the contents sampled, which is laborious and potentially hazardous to the operator. The capability to detect through-barrier would overcome these issues. Spatially Offset Raman Spectroscopy (SORS) is an innovative spectroscopic technique that avoids fluorescence and Raman scatter from containers, which can mask the Raman signature from the sample. This novel approach enables noninvasive detection of hazardous and benign materials through a wider range of container materials than is possible using conventional Raman spectroscopy. SORS spectra were acquired from explosive compounds and benign materials within a range of coloured glass and plastic containers. The SORS spectra were compared to the reference Raman signatures of the materials studied. Two data analysis methods were then applied to the resultant data to investigate the ability of SORS to detect the target materials through the barriers tested. Furthermore, the potential for reduction of sample fluorescence was investigated by using longer excitation wavelength (1064 nm) than is typically used in commercially available Raman instruments that use silicon detector technology. For some fluorescent samples, Raman spectral features that were masked by fluorescence at 785 nm were revealed at 1064 nm.
Raman Spectroscopic Imaging of the Whole Ciona intestinalis Embryo during Development
Nakamura, Mitsuru J.; Hotta, Kohji; Oka, Kotaro
2013-01-01
Intracellular composition and the distribution of bio-molecules play central roles in the specification of cell fates and morphogenesis during embryogenesis. Consequently, investigation of changes in the expression and distribution of bio-molecules, especially mRNAs and proteins, is an important challenge in developmental biology. Raman spectroscopic imaging, a non-invasive and label-free technique, allows simultaneous imaging of the intracellular composition and distribution of multiple bio-molecules. In this study, we explored the application of Raman spectroscopic imaging in the whole Ciona intestinalis embryo during development. Analysis of Raman spectra scattered from C. intestinalis embryos revealed a number of localized patterns of high Raman intensity within the embryo. Based on the observed distribution of bio-molecules, we succeeded in identifying the location and structure of differentiated muscle and endoderm within the whole embryo, up to the tailbud stage, in a label-free manner. Furthermore, during cell differentiation, we detected significant differences in cell state between muscle/endoderm daughter cells and daughter cells with other fates that had divided from the same mother cells; this was achieved by focusing on the Raman intensity of single Raman bands at 1002 or 1526 cm−1, respectively. This study reports the first application of Raman spectroscopic imaging to the study of identifying and characterizing differentiating tissues in a whole chordate embryo. Our results suggest that Raman spectroscopic imaging is a feasible label-free technique for investigating the developmental process of the whole embryo of C. intestinalis. PMID:23977129
Residual stress measurement in a metal microdevice by micro Raman spectroscopy
NASA Astrophysics Data System (ADS)
Song, Chang; Du, Liqun; Qi, Leijie; Li, Yu; Li, Xiaojun; Li, Yuanqi
2017-10-01
Large residual stress induced during the electroforming process cannot be ignored to fabricate reliable metal microdevices. Accurate measurement is the basis for studying the residual stress. Influenced by the topological feature size of micron scale in the metal microdevice, residual stress in it can hardly be measured by common methods. In this manuscript, a methodology is proposed to measure the residual stress in the metal microdevice using micro Raman spectroscopy (MRS). To estimate the residual stress in metal materials, micron sized β-SiC particles were mixed in the electroforming solution for codeposition. First, the calculated expression relating the Raman shifts to the induced biaxial stress for β-SiC was derived based on the theory of phonon deformation potentials and Hooke’s law. Corresponding micro electroforming experiments were performed and the residual stress in Ni-SiC composite layer was both measured by x-ray diffraction (XRD) and MRS methods. Then, the validity of the MRS measurements was verified by comparing with the residual stress measured by XRD method. The reliability of the MRS method was further validated by the statistical student’s t-test. The MRS measurements were found to have no systematic error in comparison with the XRD measurements, which confirm that the residual stresses measured by the MRS method are reliable. Besides that, the MRS method, by which the residual stress in a micro inertial switch was measured, has been confirmed to be a convincing experiment tool for estimating the residual stress in metal microdevice with micron order topological feature size.
Gandolfi, M G; Taddei, P; Siboni, F; Perrotti, V; Iezzi, G; Piattelli, A; Prati, C
2015-02-01
The creation of micro-textured dental implant surfaces possessing a stimulating activity represents a challenge in implant dentistry; particularly, the formation of a thin, biologically active, calcium-phosphate layer on their surface could help to strengthen the bond to the surrounding bone. The aim of the present study was to characterize in terms of macrostructure, micro-topography and reactivity in simulated body fluid (SBF), the surface of titanium (Ti) implants blasted with TiO2 particles, acid etched with hydrofluoric acid, and activated with Ca and Mg-containing nanoparticles. Sandblasted and acid-etched implants were analyzed by ESEM-EDX (environmental scanning electron microscope with energy dispersive X-ray system) to study the micromorphology of the surface and to perform elemental X-ray microanalysis (microchemical analyses) and element mapping. ESEM-EDX analyses were performed at time 0 and after a 28-day soaking period in SBF Hank's balanced salt solution (HBSS) following ISO 23317 (implants for surgery—in vitro evaluation for apatite-forming ability of implant materials). Microchemical analyses (weight % and atomic %) and element mapping were carried out to evaluate the relative element content, element distribution, and calcium/phosphorus (Ca/P) atomic ratio. Raman spectroscopy was used to assess the possible presence of impurities due to manufacturing and to investigate the phases formed upon HBSS soaking. Micro-morphological analyses showed a micro-textured, highly rough surface with microgrooves. Microchemical analyses showed compositional differences among the apical, middle, and distal thirds. The micro-Raman analyses of the as-received implant showed the presence of amorphous Ti oxide and traces of anatase, calcite, and a carbonaceous material derived from the decomposition of an organic component of lipidic nature (presumably used as lubricant). A uniform layer of Ca-poor calcium phosphates (CaPs) (Ca/P ratio <1.47) was observed after soaking in HBSS; the detection of the 961 cm⁻¹ Raman band confirms this finding. These implants showed a micro-textured surface supporting the formation of CaPs when immersed in SBF. These properties may likely favor bone anchorage and healing by stimulation of mineralizing cells.
Structural Analysis of Hand Drawn Bumblebee Bombus terrestris Silk
Woodhead, Andrea L.; Sutherland, Tara D.; Church, Jeffrey S.
2016-01-01
Bombus terrestris, commonly known as the buff-tailed bumblebee, is native to Europe, parts of Africa and Asia. It is commercially bred for use as a pollinator of greenhouse crops. Larvae pupate within a silken cocoon that they construct from proteins produced in modified salivary glands. The amino acid composition and protein structure of hand drawn B. terrestris, silk fibres was investigated through the use of micro-Raman spectroscopy. Spectra were obtained from single fibres drawn from the larvae salivary gland at a rate of 0.14 cm/s. Raman spectroscopy enabled the identification of poly(alanine), poly(alanine-glycine), phenylalanine, tryptophan, and methionine, which is consistent with the results of amino acid analysis. The dominant protein conformation was found to be coiled coil (73%) while the β-sheet content of 10% is, as expected, lower than those reported for hornets and ants. Polarized Raman spectra revealed that the coiled coils were highly aligned along the fibre axis while the β-sheet and random coil components had their peptide carbonyl groups roughly perpendicular to the fibre axis. The protein orientation distribution is compared to those of other natural and recombinant silks. A structural model for the B. terrestris silk fibre is proposed based on these results. PMID:27447623
Hollow fiber-optic Raman probes for small experimental animals
NASA Astrophysics Data System (ADS)
Katagiri, Takashi; Hattori, Yusuke; Suzuki, Toshiaki; Matsuura, Yuji; Sato, Hidetoshi
2007-02-01
Two types of hollow fiber-optic probes are developed to measure the in vivo Raman spectra of small animals. One is the minimized probe which is end-sealed with the micro-ball lens. The measured spectra reflect the information of the sample's sub-surface. This probe is used for the measurement of the esophagus and the stomach via an endoscope. The other probe is a confocal Raman probe which consists of a single fiber and a lens system. It is integrated into the handheld microscope. A simple and small multimodal probe is realized because the hollow optical fiber requires no optical filters. The performance of each probe is examined and the effectiveness of these probes for in vivo Raman spectroscopy is shown by animal tests.
Raman mapping probing of tip-induced anomalous polarization behavior in V2O5 waveguiding nanoribbons
NASA Astrophysics Data System (ADS)
Yan, Bin; Du, Chaoling; Liao, Lei; You, Yumeng; Cheng, Hao; Shen, Zexiang; Yu, Ting
2010-02-01
Spatially resolved and polarized micro-Raman spectroscopy has been performed on individual V2O5 waveguiding nanoribbons. The experimental results establish that the Raman-antenna patterns are strongly correlated with the local positions of the sample, which gives rise to a pronounced intensity contrast in the polarized mapping for certain phonon modes. The suppressed phonon signals at the body of a ribbon can be enhanced at the end facets, resulting from the effective waveguiding propagation along the nanoribbon and strong local electric field intensity at the ends. The phenomena reported here, in addition to providing insight into the tip effects on optoelectronic nanodevices, will facilitate the rational design of Raman detection in nanostructures.
Scalable and reusable micro-bubble removal method to flatten large-area 2D materials
NASA Astrophysics Data System (ADS)
Pham, Phi H. Q.; Quach, Nhi V.; Li, Jinfeng; Burke, Peter J.
2018-04-01
Bubbles generated during electro-delamination and chemical etch during large-area two-dimensional (2D) material transfer has been shown to cause rippling, and consequently, results in tears and wrinkles in the transferred film. Here, we demonstrate a scalable and reusable method to remove surface adhered micro-bubbles by using hydrophobic surfaces modified by self-assembled monolayers (SAMs). Bubble removal allows the 2D film to flatten out and prevents the formation of defects. Electrical characterization was used to verify improved transfer quality and was confirmed by increased field-effect mobility and decreased sheet resistance. Raman spectroscopy was also used to validate enhanced electrical quality following transfer. The bubble removal method can be applied to an assortment of 2D materials using diverse hydrophobic SAM variants. Our studies can be integrated into large scale applications and will lead to improved large-area 2D electronics in general.