2012-12-01
TROPIC CONDITIONS: EFFECTS OF THREE MICROCLIMATE COOLING CONFIGURATIONS Bruce S. Cadarette Catherine O’Brien Thermal and Mountain...Cooling HR – Heart Rate INT – Intermittent Cooling LO – Low Cooling MCCS – Microclimate Cooling System NC – No Cooling NSRDEC – Natick...develop lightweight microclimate cooling systems (MCCS) for use by dismounted Soldiers by evaluating the cooling potentials of two prototype MCCS
2012-12-01
USARIEM TECHNICAL REPORT PHYSIOLOGICAL RESPONSES TO MICROCLIMATE COOLING USED BY THE AIR SOLDIER DRESSED AT MOPP 4 IN AN...2012 2. REPORT TYPE 4. TITLE AND SUBTITLE 5a. CONTRACT NUMBER Physiological Responses to Microclimate Cooling Used By the Air Soldier 5b. GRANT... Microclimate Cooling System MCG HI – Air Warrior Microclimate Cooling Garment Used in High Cooling Configuration MCG LO - Air Warrior Microclimate
Evaluation of Commercial Off-the-Shelf and Government Off-the-Shelf Microclimate Cooling Systems
2005-08-01
Appendix A - Request for Information (RFI) 23 Appendix B - Memorandum from Natick Soldier Center’s International Office 25 Appendix C - Cooling Power...Data Entry Forms 7 Figure 3. Evaporative Cooling Products 9 Figure 4. Passive Phase Change Product 10 Figure 5. Liquid Circulating...Microclimate Cooling System 13 Figure 6. Compressed Air Cooling Product 15 Figure 7. Vortex Tube 15 Figure 8. Active Phase
NASA Microclimate Cooling Challenges
NASA Technical Reports Server (NTRS)
Trevino, Luis A.
2004-01-01
The purpose of this outline form presentation is to present NASA's challenges in microclimate cooling as related to the spacesuit. An overview of spacesuit flight-rated personal cooling systems is presented, which includes a brief history of cooling systems from Gemini through Space Station missions. The roles of the liquid cooling garment, thermal environment extremes, the sublimator, multi-layer insulation, and helmet visor UV and solar coatings are reviewed. A second section is presented on advanced personal cooling systems studies, which include heat acquisition studies on cooling garments, heat rejection studies on water boiler & radiators, thermal storage studies, and insulation studies. Past and present research and development and challenges are summarized for the advanced studies.
2012-04-01
3.1 % RH. The microclimate within helicopters can be extreme, with elevated air temperatures, relative humidity, and solar load, with the greenhouse...experienced by helicopter pilots. Katz et al. (11) reported that an Air Warrior Chemical Protective ensemble with microclimate cooling was effective...study showed that a microclimate cooling system worn next to the skin could alleviate some of the thermal burden experienced (10). Banta and Braun
Evaluation of Three Commercial Microclimate Cooling Systems
1988-11-01
easily counteracted because of the difficulty of drinking inside protective clothing . Dehydration combined with warm skin and exercise can easily result in...Stress; Exercise ; Thermoregulation 9. ABSTRACT (Continue on reverse if necessary and identify by block number) (OThree commercially available microclimate...cooling systems were evaluated for their abil- ity to reduce heat stress in men exercising in a hot environment while wearing high insula- tive, low
Microclimate Cooling Systems: A Shipboard Evaluation of Commercial Models
1988-04-01
NCTRF), under contract to the Navy SciencI Assistance Program (NSAP), evaluated the feasibility of using commercial microclimate coolin9" systems (MCS...exterior of the air distribution vest be covered with a fire-retardant material similar to the type used in this evaluation. The results of this evaluation
2012-08-01
soldiers via microclimate cooling [13]. Unfortunately, a common method for direct cooling of the soldiers – surface cooling – can cause cutaneous...Intermittent, Regional Microclimate Cooling," Journal of Applied Physiology, vol. 94, pp. 1841-48, 2003. [18] L. A. Stephenson, C. R. Vernieuw, W...Leammukda and M. A. Kolka, "Skin Temperature Feedback Optimizes Microclimate Cooling," Aviation, Space and Environmental Medicine, vol. 78, pp. 377-382
Evaluation of three commercial microclimate cooling systems
NASA Astrophysics Data System (ADS)
Cadarette, Bruce S.; Decristofano, Barry S.; Speckman, Karen N.; Sawka, Michael N.
1988-11-01
Three commercially available microclimate cooling systems were evaluated for their ability to reduce heat stress in men exercising in a hot environment while wearing high insulative, low permeability clothing. The cooling systems were: (1) ILC Dover Model 19 Coolvest (ILC) (2) LSSI Coolhead(LSSI), and (3) Thermacor Cooling vest (THERM). Endurance Time (ET), Heart Rate (HR), rectal temperature (Tre), mean skin temperature (TSK), Sweating Rate (SR), Rated Perceived Exertion (RPE) and Thermal Sensation (TS) were measured. The subjects self-terminated on all LSSI tests because of headaches. Statistical analyses were performed on data collected at 60 minutes to have values on all subjects. There were no differences in HR, Tre, SR or TS values among the cooling vests. The subjects' TSK was lower (P less than 0.05) for the LSSI than THERM: and RPE values were higher (P less than 0.05) for LSSI than the other two vests. These data suggest an improved physiological response to exercise heat stress with all three commercial systems with the greatest benefit in performance time provided by the ILC cooling system.
Chan, Albert P C; Song, Wenfang; Yang, Yang
2015-01-01
This study aims to determine the appropriate microclimate cooling systems (MCSs) to reduce heat stress and improve human performance of occupational workers and their practicality in the occupational field. Meta-analysis was employed to summarize, analyze, and compare the effects of various MCSs on human performance with corresponding physiological and psychological responses, thereby providing solid suggestions for selecting suitable MCSs for occupational workers. Wearing MCSs significantly attenuated the increases in core temperature (-0.34 °C/h) and sweating rate (-0.30 L/h), and significantly improved human performance (+29.9%, effect size [EFS] = 1.1) compared with no cooling condition (CON). Cold air-cooled garments (ACG-Cs; +106.2%, EFS = 2.32) exhibited greater effects on improving human performance among various microclimate cooling garments (MCGs), followed by liquid cooling garments (LCGs; +68.1%, EFS = 1.86) and hybrid cooling garment combining air and liquid cooling (HBCG-AL; +59.1%, EFS=3.38), natural air-cooled garments (ACG-Ns; +39.9%, EFS = 1.12), and phase change material cooling garments (PCMCGs; +19.5%, EFS = 1.2). Performance improvement was observed to be positively and linearly correlated to the differences of core temperature increase rate (r = 0.65, p < 0.01) and sweating rate (r = 0.80, p < 0.001) between MCSs and CON. Considering their application in industrial settings, ACG-Cs, LCGs, and HBCG-AL are practical for work, in which workers do not move frequently, whereas ACG-Ns and PCMCGs are more applicable for the majority of occupational workers. Further enhancement of the cooling efficiency of these two cooling strategies should be initiated. Copyright © 2015 Elsevier Ltd. All rights reserved.
Phase change thermal energy storage methods for combat vehicles, phase 1
NASA Astrophysics Data System (ADS)
Lynch, F. E.
1986-06-01
Three alternative cooling methods, based on latent heat absorption during phase changes, were studied for potential use in combat vehicle microclimate temperature control. Metal hydrides absorb heat as they release hydrogen gas. Plastic crystals change from one solid phase to another, absorbing heat in the process. Liquid air boils at cryogenic temperature and absorbs additional sensible heat as the cold gas mixes with the microclimate air flow. System designs were prepared for each of the three microclimate cooling concepts. These designs provide details about the three phase change materials, their containers and the auxiliary equipment needed to implement each option onboard a combat vehicle. The three concepts were compared on the basis of system mass, system volume and the energy required to regenerate them after use. Metal hydrides were found to be the lightest and smallest option by a large margin. The energy needed to regenerate a hydride thermal storage system can be extracted from the vehicle's exhaust gases.
Cooling Effectiveness of a Hybrid Microclimate Garment
1988-04-01
ELEMENT NO . NO . NO . JCCESSION NO .63747 D669 35 Cooling Effectiveness of a Hybrid Microclimate Garment (U) 12. PERSONAL AUTHOR(S) Barry S...be arranged. Therefore, no direct measurement of the cooling rate achieved by the air garments was obtained. After calculation of the liquid cooling...Cooling Performance. There was no significant difference between the levels of heat removed by the liquid and hybrid-liquid garments . The measured
NASA Technical Reports Server (NTRS)
1993-01-01
The Mark VII MicroClimate Medical Personal Cooling system enables multiple sclerosis' victims, as well as cerebral palsy, spinabifida patients and others to lower their body temperatures. Although this is not a cure, cooling can produce a dramatic improvement in symptoms. The Multiple Sclerosis Association of America has placed cool suits in MS research care centers. This technology originated in the need for cooling systems in spa@esuits. "Cool Suits" are now used by hazardous materials workers, armored vehicle crews, firefighters and crop dusters. A surgical personal cooling system has also been developed for medical personnel working in hot operating room environments.
Thermal Comfort and Sensation in Men Wearing a Cooling System Controlled by Skin Temperature
2007-07-01
The study was done to determine whether thermal comfort (TC), thermal sensation (TS), and subjective factors gauging environmental stress were...improvement in thermal comfort . Methods: Eight male volunteers exercised at moderate work intensity (425 W) in three microclimate cooling tests. The
2009-10-01
and ratings of thermal comfort (TC) were measured at regular intervals. 3.0 RESULTS In study one, all IR1-4 paradigms significantly reduced... Thermal comfort and sensation in men wearing a cooling system controlled by skin temperatrure. Human Factors 49: 1033-1044, 2007. [7] Xu X
Heat removal using microclimate foot cooling: a thermal foot manikin study.
Castellani, John W; Demes, Robert; Endrusick, Thomas L; Cheuvront, Samuel N; Montain, Scott J
2014-04-01
It has been proposed that microclimate cooling systems exploit the peripheral extremities because of more efficient heat transfer. The purpose of this study was to quantify, using a patented microclimate cooling technique, the heat transfer from the plantar surface of the foot for comparison to other commonly cooled body regions. A military boot was fitted with an insole embedded with a coiled, 1.27 m length of hollow tubing terminating in inlet and outlet valves. A thermal foot manikin with a surface temperature of 34 degrees C was placed in the boot and the valves were connected to a system that circulated water through the insole at a temperature of 20 degrees C and flow rate of 120 ml x min(-1). The manikin foot served as a constant heat source to determine heat transfer provided by the insole. Testing was done with the foot model dry and sweating at a rate of 500 ml x h(- 1) x m(-2). Climatic chamber conditions were 30 degrees C with 30% RH. Heat loss was approximately 4.1 +/- 0.1 and approximately 7.7 +/- 0.3 W from the dry and sweating foot models, respectively. On a relative scale, the heat loss was 3.0 W and 5.5 W per 1% (unit) body surface area, respectively, for the dry and sweating conditions. The relative heat loss afforded by plantar foot cooling was similar compared to other body regions, but the absolute amount of heat removal is unlikely to make an impact on whole body heat balance.
Crum, Steven M; Shiflett, Sheri A; Jenerette, G Darrel
2017-09-15
Many cities are increasing vegetation in part due to the potential for microclimate cooling. However, the magnitude of vegetation cooling and sensitivity to mesoclimate and meteorology are uncertain. To improve understanding of the variation in vegetation's influence on urban microclimates we asked: how do meso- and regional-scale drivers influence the magnitude and timing of vegetation-based moderation on summertime air temperature (T a ), relative humidity (RH) and heat index (HI) across dryland cities? To answer this question we deployed a network of 180 temperature sensors in summer 2015 over 30 high- and 30 low-vegetated plots in three cities across a coastal to inland to desert climate gradient in southern California, USA. In a followup study, we deployed a network of temperature and humidity sensors in the inland city. We found negative T a and HI and positive RH correlations with vegetation intensity. Furthermore, vegetation effects were highest in evening hours, increasing across the climate gradient, with reductions in T a and increases in RH in low-vegetated plots. Vegetation increased temporal variability of T a , which corresponds with increased nighttime cooling. Increasing mean T a was associated with higher spatial variation in T a in coastal cities and lower variation in inland and desert cities, suggesting a climate dependent switch in vegetation sensitivity. These results show that urban vegetation increases spatiotemporal patterns of microclimate with greater cooling in warmer environments and during nighttime hours. Understanding urban microclimate variation will help city planners identify potential risk reductions associated with vegetation and develop effective strategies ameliorating urban microclimate. Published by Elsevier Ltd.
Novel Cooling Strategies for Military Training and Operations.
Lee, Jason K W; Kenefick, Robert W; Cheuvront, Samuel N
2015-11-01
The deleterious effects of environmental heat stress, combined with high metabolic loads and protective clothing and equipment of the modern Warfighter, impose severe heat strain, impair task performance, and increase risk of heat illness, thereby reducing the chance for mission success. Despite the implementation of heat-risk mitigation procedures over the past decades, task performance still suffers and exertional heat illness remains a major military problem. We review 3 novel heat mitigation strategies that may be implemented in the training or operational environment to reduce heat strain and the risk of exertional heat illness. These strategies include ingestion of ice slurry, arm immersion cooling, and microclimate cooling. Each of these strategies is suitable for use in different scenarios and the choice of cooling strategy is contingent on the requirements, circumstances, and constraints of the training and operational scenario. Ingestion of ice slurry and arm immersion cooling are practical strategies that may be implemented during training scenarios; ice slurry can be ingested before and during exercise, whereas arm immersion cooling can be administered after exercise-heat exposure. In the operational environment, existing microclimate cooling can be implemented with retrofitted vehicles and as an unmounted system, and it has the potential for use in many military occupational scenarios. This review will discuss the efficacy, limitations, and practical considerations for field implementation of each strategy.
Technology Evaluation for an Advanced Individual Protection System (AIPS)
1992-12-01
this analysis are: time of operation, duration of thermal management, power consumed during operation, cooling/heating benefit , time between recharge...BRDEC) TOPICS: o individual power * batteries/engines/fuel cel!s POC: Wes Goodwin (NRDEC) TOPICS: * microclimate cooling e vapor compression cycles e...individual power 2.3 LITERATURE SEARCHES The literature searches began by reviewing Battelle in-house sources for useful reports. This included a
Proposed Standard for a Microclimate Cooling System for Emergency Responder Operations
2012-02-17
shock, circuit damage, overheating, fire , or explosion. If applicable, MCS vendors shall provide a certificate of compliance, which specifically cites...2, each configuration includes underwear , a duty uniform, ballistic helmet, and, boots. Table A-2 CBP PPE Configurations Configuration Components
Compensation and climate: Latitudinal variation in ecototherm response to environmental change
DOE Office of Scientific and Technical Information (OSTI.GOV)
Curtin, C.G.
1995-06-01
Thermal preference measured in a laboratory thermal gradient, and field body temperatures in a field enclosure, contrast the fundamental and realized thermal niches of ornate box turtles (Terrapene ornata) from northern, central, and southern locations. The relatively warmer thermal preference of southern turtles appears to result in lower body temperatures and relatively shorter activity periods. Variation in thermal constraints are input into computer simulations of ectotherm response to climate to assess latitudinal variation in turtle response to microclimate cooling (4{degrees} C), current climate (1970-1990), and climatic warming (3-5{degrees} C). Climatic warming is calculated to lead to a northward shift inmore » turtle range and distribution with increases in northern and declines in southern populations. Microclimate cooling is estimated to result in declines in northern areas and in the core of the box turtle range. The local changes in microclimate, such as can result from shifts in land-use, can be greater than those resulting from large scale changes in climate. Suggesting that land managers and conservation biologists need to focus greater attention on the impact of changes in within patch structure of plant associations and its implications for alteration of microclimate and species life history.« less
Developing 3D morphologies for simulating building energy demand in urban microclimates
DOE Office of Scientific and Technical Information (OSTI.GOV)
New, Joshua Ryan; Omitaomu, Olufemi A.; Allen, Melissa R.
In order to simulate the effect of interactions between urban morphology and microclimate on demand for heating and cooling in buildings, we utilize source elevation data to create 3D building geometries at the neighborhood and city scale. Additionally, we use urban morphology concepts to design virtual morphologies for simulation scenarios in an undeveloped land parcel. Using these morphologies, we compute building-energy parameters such as the density for each surface and the frontal area index for each of the buildings to be able to effectively model the microclimate for the urban area.
NASA Astrophysics Data System (ADS)
Broadbent, Ashley M.; Coutts, Andrew M.; Tapper, Nigel J.; Demuzere, Matthias; Beringer, Jason
2017-09-01
Prolonged drought has threatened traditional potable urban water supplies in Australian cities, reducing capability to adapt to climate change and mitigate against extreme. Integrated urban water management (IUWM) approaches, such as water sensitive urban design (WSUD), reduce the reliance on centralised potable water supply systems and provide a means for retaining water in the urban environment through stormwater harvesting and reuse. This study examines the potential for WSUD to provide cooling benefits and reduce human exposure and heat stress and thermal discomfort. A high-resolution observational field campaign, measuring surface level microclimate variables and remotely sensed land surface characteristics, was conducted in a mixed residential suburb containing WSUD in Adelaide, South Australia. Clear evidence was found that WSUD features and irrigation can reduce surface temperature (T s) and air temperature (T a) and improve human thermal comfort (HTC) in urban environments. The average 3 pm T a near water bodies was found to be up to 1.8 °C cooler than the domain maximum. Cooling was broadly observed in the area 50 m downwind of lakes and wetlands. Design and placement of water bodies were found to affect their cooling effectiveness. HTC was improved by proximity to WSUD features, but shading and ventilation were also effective at improving thermal comfort. This study demonstrates that WSUD can be used to cool urban microclimates, while simultaneously achieving other environmental benefits, such as improved stream ecology and flood mitigation.
USAF Physiological Studies of Personal Microclimate Cooling: A Review
1993-05-01
53 vi 11h. Thermal comfort ratings during continuous work. AC = Ambient Air Cooling; NC = No Cooling...43 10b Thermal Comfort (TC) and Rating of Perceived Exertion (RPE) at the End of 45-Min Work Cycles in...47 10d Thermal Comfort (TC) and Ratings of Perceived Exertion (RPE) at the End o! 30
[Occupational microclimate. Results and prospects of research].
Afanas'eva, R F; Bessonova, N A; Burmistrova, O V; Burmistrov, V M; Losik, T K
2013-01-01
The article covers results of studies conducted over last 15 years and aimed to elaboration of requirements to integral parameters of microclimate at workplace, its evaluation and regulation, prophylactic measures against body overcooling and overheating. The authors present methods to evaluate combined effects of physical factors (noise, vibration, microclimate) and to assess microclimate with consideration of factors determining body thermal load (energy expenditure, duration of stay at workplace, heat insulation of clothes and thermo-physical parameters of its materials). Mathematic models of forecasting cold and heat stress are presented, as well as requirements to heat insulation for individual protective means against cold and methods to calculate it. Regimens of work in heating and cooling conditions are specified. The authors set directions for further studies to define regulation requirements to microclimate on basis of studied patterns of body heat state formation, its evaluation criteria, epidemiologic studies results, specified prophylactic measures against overheating and overcooling with consideration of adaptation, sex, thermo-physical characteristics of individual protective means (special clothes, footwear, gauntlets, headwear).
NASA Astrophysics Data System (ADS)
Prorokova, M. V.; Bukhmirov, V. V.
2016-02-01
The article describes the method of valuation of comfort of microclimate of residen-tial, public and administrative buildings. The method is based on calculation of the coefficient of thermal comfort of a person in the room. Further amendments are introduced to the asym-metry of the thermal radiation, radiation cooling and air quality. The method serves as the basis for a computer program.
Influence of season and microclimate on fertility of dairy cows in a hot-arid environment
NASA Astrophysics Data System (ADS)
Ray, D. E.; Jassim, A. H.; Armstrong, D. V.; Wiersma, F.; Schuh, J. D.
1992-09-01
Records were obtained over a 3 year period from six Holstein dairy farms of 300 to 500 cows each in the Phoenix, Ariz. area. Dairies were selected on the basis of similar management practices, herd size, milk production and facilities (with the exception of cooling systems). Microclimatic modifications (two dairies each) were shade only (approximately 3.7 m2/cow), evaporative-cooled shades and low-pressure water foggers under the shades. Data were categorized by season of calving (spring, Feb. May; summer, June Sept.; and fall, Oct. Jan.). Traits evaluated were calving interval, days open and services/conception. Calving interval was shortest for cows calving in the spring (378 days), intermediate in fall (382 days) and longest in summer (396 days). Similar seasonal trends were observed for days open (103, 103 and 119 days, respectively) and services/conception (1.54, 1.81 and 1.93, respectively). All differences between spring and summer were significant ( P < 0.05). Calving interval and days open were less for evaporative-cooled groups (374 and 98 days, respectively), with no difference between shade only and foggers (391 and 392 days, 112 and 116 days, respectively). Services/conception were similar for all groups (1.72 to 1.79). A significant interaction between microclimate and season for services/conception could be interpreted as (i) smaller season differences for evaporative-cooled groups than for shade or foggers, or (ii) a change in the ranking of control and fogger groups during summer versus fall. Evaporative cooling was more effective than fogging for reducing the detrimental effects of seasonal high temperatures on fertility.
Glitz, K J; Seibel, U; Rohde, U; Gorges, W; Witzki, A; Piekarski, C; Leyk, D
2015-01-01
Heat stress caused by protective clothing limits work time. Performance improvement of a microclimate cooling method that enhances evaporative and to a minor extent convective heat loss was tested. Ten male volunteers in protective overalls completed a work-rest schedule (130 min; treadmill: 3 × 30 min, 3 km/h, 5% incline) with or without an additional air-diffusing garment (climatic chamber: 25°C, 50% RH, 0.2 m/s wind). Heat loss was supported by ventilating the garment with dry air (600 l/min, ≪5% RH, 25°C). Ventilation leads (M ± SD, n = 10, ventilated vs. non-ventilated) to substantial strain reduction (max. HR: 123 ± 12 b/min vs. 149 ± 24 b/min) by thermal relief (max. core temperature: 37.8 ± 0.3°C vs. 38.4 ± 0.4°C, max. mean skin temperature: 34.7 ± 0.8°C vs. 37.1 ± 0.3°C) and offers essential extensions in performance and work time under thermal insulation. Heat stress caused by protective clothing limits work time. Performance can be improved by a microclimate cooling method that supports evaporative and to a minor extent convective heat loss. Sweat evaporation is the most effective thermoregulatory mechanism for heat dissipation and can be enhanced by insufflating dry air into clothing.
Influence of season and microclimate on fertility of dairy cows in a hot-arid environment.
Ray, D E; Jassim, A H; Armstrong, D V; Wiersma, F; Schuh, J D
1992-08-01
Records were obtained over a 3 year period from six Holstein dairy farms of 300 to 500 cows each in the Phoenix, Ariz. area. Dairies were selected on the basis of similar management practices, herd size, milk production and facilities (with the exception of cooling systems). Microclimatic modifications (two dairies each) were shade only (approximately 3.7 m2/cow), evaporative-cooled shades and low-pressure water foggers under the shades. Data were categorized by season of calving (spring, Feb.-May; summer, June-Sept.; and fall, Oct.-Jan.). Traits evaluated were calving interval, days open and services/conception. Calving interval was shortest for cows calving in the spring (378 days), intermediate in fall (382 days) and longest in summer (396 days). Similar seasonal trends were observed for days open (103, 103 and 119 days, respectively) and services/conception (1.54, 1.81 and 1.93, respectively). All differences between spring and summer were significant (P less than 0.05). Calving interval and days open were less for evaporative-cooled groups (374 and 98 days, respectively), with no difference between shade only and foggers (391 and 392 days, 112 and 116 days, respectively). Services/conception were similar for all groups (1.72 to 1.79). A significant interaction between microclimate and season for services/conception could be interpreted as (i) smaller season differences for evaporative-cooled groups than for shade or foggers, or (ii) a change in the ranking of control and fogger groups during summer versus fall. Evaporative cooling was more effective than fogging for reducing the detrimental effects of seasonal high temperatures on fertility.
NASA Astrophysics Data System (ADS)
Rajewski, Daniel A.; Takle, Eugene S.; Prueger, John H.; Doorenbos, Russell K.
2016-11-01
Recent wind farm studies have revealed elevated nighttime surface temperatures but have not validated physical mechanisms that create the observed effects. We report measurements of concurrent differences in surface wind speed, temperature, fluxes, and turbulence upwind and downwind of two turbine lines at the windward edge of a utility-scale wind farm. On the basis of these measurements, we offer a conceptual model based on physical mechanisms of how wind farms affect their own microclimate. Periods of documented curtailment and zero-power production of the wind farm offer useful opportunities to rigorously evaluate the microclimate impact of both stationary and operating turbines. During an 80 min nighttime wind farm curtailment, we measured abrupt and large changes in turbulent fluxes of momentum and heat leeward of the turbines. At night, wind speed decreases in the near wake when turbines are off but abruptly increases when turbine operation is resumed. Our measurements are compared with Moderate Resolution Imaging Spectroradiometer Terra and Aqua satellite measurements reporting wind farms to have higher nighttime surface temperatures. We demonstrate that turbine wakes modify surface fluxes continuously through the night, with similar magnitudes during the Terra and Aqua transit periods. Cooling occurs in the near wake and warming in the far wake when turbines are on, but cooling is negligible when turbines are off. Wind speed and surface stratification have a regulating effect of enhancing or decreasing the impact on surface microclimate due to turbine wake effects.
Habitat associations of species show consistent but weak responses to climate
Suggitt, Andrew J.; Stefanescu, Constantí; Páramo, Ferran; Oliver, Tom; Anderson, Barbara J.; Hill, Jane K.; Roy, David B.; Brereton, Tom; Thomas, Chris D.
2012-01-01
Different vegetation types can generate variation in microclimates at local scales, potentially buffering species from adverse climates. To determine if species could respond to such microclimates under climatic warming, we evaluated whether ectothermic species (butterflies) can exploit favourable microclimates and alter their use of different habitats in response to year-to-year variation in climate. In both relatively cold (Britain) and warm (Catalonia) regions of their geographical ranges, most species shifted into cooler, closed habitats (e.g. woodland) in hot years, and into warmer, open habitats (e.g. grassland) in cooler years. Additionally, three-quarters of species occurred in closed habitats more frequently in the warm region than in the cool region. Thus, species shift their local distributions and alter their habitat associations to exploit favourable microclimates, although the magnitude of the shift (approx. 1.3% of individuals from open to shade, per degree Celsius) is unlikely to buffer species from impacts of regional climate warming. PMID:22491762
Mangrove microclimates alter seedling dynamics at the range edge.
Devaney, John L; Lehmann, Michael; Feller, Ilka C; Parker, John D
2017-10-01
Recent climate warming has led to asynchronous species migrations, with major consequences for ecosystems worldwide. In woody communities, localized microclimates have the potential to create feedback mechanisms that can alter the rate of species range shifts attributed to macroclimate drivers alone. Mangrove encroachment into saltmarsh in many areas is driven by a reduction in freeze events, and this encroachment can further modify local climate, but the subsequent impacts on mangrove seedling dynamics are unknown. We monitored microclimate conditions beneath mangrove canopies and adjacent open saltmarsh at a freeze-sensitive mangrove-saltmarsh ecotone and assessed survival of experimentally transplanted mangrove seedlings. Mangrove canopies buffered night time cooling during the winter, leading to interspecific differences in freeze damage on mangrove seedlings. However, mangrove canopies also altered biotic interactions. Herbivore damage was higher under canopies, leading to greater mangrove seedling mortality beneath canopies relative to saltmarsh. While warming-induced expansion of mangroves can lead to positive microclimate feedbacks, simultaneous fluctuations in biotic drivers can also alter seedling dynamics. Thus, climate change can drive divergent feedback mechanisms through both abiotic and biotic channels, highlighting the importance of vegetation-microclimate interactions as important moderators of climate driven range shifts. © 2017 by the Ecological Society of America.
SIMULATION OF A BIOFEEDBACK MICROCLIMATE COOLING SYSTEM USING A HUMAN THERMOREGULATION MODEL
2017-02-01
garment (LCG) The rate of LCG heat removal from the human body depends on coolant inlet temperature (Tin), clothing insulation worn over the LCG, flow...The efficiency η is equal to one when the outer clothing has sufficient insulation and the heat exchange between LCG and the external environment...0.27 m2·ºC·W-1 (1.73 clo). Insulation of protective ensembles prevent the LCG from absorbing heat from the environment (circulating liquid temperature
Urban geometry effects on the microclimate of streets near the river
NASA Astrophysics Data System (ADS)
Park, C.; Lee, D. K.; Asawa, T.; Murakami, A.; Kim, H. G.; Jeong, W.
2016-12-01
These days, many urbans have undergone urban heat islands (UHIs) which mean urban areas have higher temperature than surrounding areas. Because of UHIs, extreme heat waves and tropical nights threaten citizen's health. For reducing UHI effects, UHIs mitigation strategies related with urban planning (cooling elements, urban geometry, and urban materials) are studied in many fields. Especially, cooling elements such as vegetation and water are important for making sustainable cities. However, while the each effects of cooling elements are known, combination effects between urban geometry and elements are not clearly defined. To determine which urban geometry is effective to decrease air temperature, we analyzed urban geometry effects on the microclimate of streets near the river. The urban streets located in commercial area near the Cheonggye River and they had different aspect ratio. For doing this, we used field measurement. Field measurement were takin in the sunny days of July and August 2016. Air temperature measurement used T-type thermometers with cylindrical tube and ventilation fan. Wind measurements used kestrel 4500 for wind speed and wind direction. We measured air temperature in the screen level and repeated three times an hour. Measurement results showed that large aspect ratio street show lower air temperature than small ones. And they received cooling effect farther than others from the river. This is because that cooling air flows well in the wide road streets. Large aspect ratio streets are effective to receive river's cooling air. These results can be used in the urban geometry planning near the river.
Chambers, Ute; Jones, Vincent P
2015-12-01
Orchard design and management practices can alter microclimate and, thus, potentially affect insect development. If sufficiently large, these deviations in microclimate can compromise the accuracy of phenology model predictions used in integrated pest management (IPM) programs. Sunburn causes considerable damage in the Pacific Northwest, United States, apple-producing region. Common prevention strategies include the use of fruit surface protectants, evaporative cooling (EC), or both. This study focused on the effect of EC on ambient temperatures and model predictions for four insects (codling moth, Cydia pomonella L.; Lacanobia fruitworm, Lacanobia subjuncta Grote and Robinson; oblique-banded leafroller, Choristoneura rosaceana Harris; and Pandemis leafroller, Pandemis pyrusana Kearfott). Over-tree EC was applied in July and August when daily maximum temperatures were predicted to be ≥30°C between 1200-1700 hours (15/15 min on/off interval) in 2011 and between 1200-1800 hours (15/10 min on/off interval, or continuous on) in 2012. Control plots were sprayed once with kaolin clay in early July. During interval and continuous cooling, over-tree cooling reduced average afternoon temperatures compared with the kaolin treatment by 2.1-3.2°C. Compared with kaolin-treated controls, codling moth and Lacanobia fruitworm egg hatch in EC plots was predicted to occur up to 2 d and 1 d late, respectively. The presence of fourth-instar oblique-banded leafroller and Pandemis leafroller was predicted to occur up to 2 d and 1 d earlier in EC plots, respectively. These differences in model predictions were negligible, suggesting that no adjustments in pest management timing are needed when using EC in high-density apple orchards. © The Authors 2015. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Rockweit, Jeremy T.; Franklin, Alan B.; Bakken, George S.; Gutiérrez, R. J.
2012-01-01
Many bird species do not make their own nests; therefore, selection of existing sites that provide adequate microclimates is critical. This is particularly true for owls in north temperate climates that often nest early in the year when inclement weather is common. Spotted owls use three main types of nest structures, each of which are structurally distinct and may provide varying levels of protection to the eggs or young. We tested the hypothesis that spotted owl nest configuration influences nest microclimate using both experimental and observational data. We used a wind tunnel to estimate the convective heat transfer coefficient (hc) of eggs in 25 potential nest configurations that mimicked 2 nest types (top-cavity and platform nests), at 3 different wind speeds. We then used the estimates of hc in a biophysical heat transfer model to estimate how long it would take unattended eggs to cool from incubation temperature (∼36°C) to physiological zero temperature (PZT; ∼26°C) under natural environmental conditions. Our results indicated that the structural configuration of nests influences the cooling time of the eggs inside those nests, and hence, influences the nest microclimate. Estimates of time to PZT ranged from 10.6 minutes to 33.3 minutes. Nest configurations that were most similar to platform nests always had the fastest egg cooling times, suggesting that platform nests were the least protective of those nests we tested. Our field data coupled with our experimental results suggested that nest choice is important for the reproductive success of owls during years of inclement weather or in regions characterized by inclement weather during the nesting season. PMID:22859993
Li, Ying-Han; Wang, Jun-Jian; Chen, Xue; Sun, Jian-Lin; Zeng, Hui
2011-02-01
Based on field survey and landscape pattern analysis, this paper studied the effects of green space vegetation canopy on the microclimate in three typical residential quarters in Shenzhen City. In each of the residential quarters, 22-26 points were chosen for meteorological observation; and around each of the observation points, a 20 m x 20 m quadrat was installed, with each quadrat divided into two different patches, one covered by vegetation canopy and the another no-covered. The patch density index (D(p)) and contagion index (CONTAG) in each quadrat were calculated to analyze the relationships between vegetation canopy pattern index and microclimate in each point. The results showed that the green space vegetation canopy pattern in Shenzhen had significant regulation effect on temperature and humidity. The cooling effect was mainly from the shading effect of vegetation, and also, correlated with vegetation quantity. The increase in the CONTAG of bare surface had obvious negative effects on the regulation effect of vegetation on microclimate. The regulation capability of green space vegetation on the temperature and humidity in residential quarters mainly came from tall arbor species.
Body Temperature Versus Microclimate Selection in Heat Stressed Dairy Cows
USDA-ARS?s Scientific Manuscript database
The purpose of this study is to characterize the thermoregulatory responses of unrestrained heat-stressed dairy cows within a freestall environment using fan and spray configurations for cooling cows while lying or standing. An experimental treatment sprayed individual cows lying in freestalls from ...
Biomedical Application of Aerospace Personal Cooling Systems
NASA Technical Reports Server (NTRS)
Ku, Yu-Tsuan E.; Lee, Hank C.; Montgomery, Leslie D.; Webbon, Bruce W.; Kliss, Mark (Technical Monitor)
1997-01-01
Personal thermoregulatory systems which are used by astronauts to alleviate thermal stress during extravehicular activity have been applied to the therapeutic management of multiple sclerosis. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive and two active cooling vests and to measure the body temperature and circulatory changes produced by each cooling vest configuration. The MicroClimate Systems and the Life Enhancement Tech(LET) lightweight liquid cooling vests, the Steele Vest and LET's Zipper Front Garment were used to cool the chest region of 10 male and female subjects (25 to 55 yr.) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approx.22C), were tested for 60 min. with the cooling system operated at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. In general, the male and female subjects' oral and ear temperature responses to cooling were similar for all vest configurations tested. Oral temperatures during the recovery period were significantly (P<0.05) lower than during the control period, approx. 0.2 - 0.5C, for both men and women wearing any of the four different garments. The corresponding ear temperatures were significantly (P<0.05) decreased approx.0.2 - 0.4C by the end of the recovery period. Compared to the control period, no significant differences were found in rectal temperatures during cooling and recovery periods.
Lightweight Passive Microclimate Cooling Device
1993-03-01
rabrication. No consideration was given to weight. We have examined alternate methods of construction of the backpack and cylinder assembly and thin...13 Figure 7. Water Adsorption on Magnesium Chloride ........... 14 Figure 8. Cylinder Assembly ................................ 20...Figure 9. Backpack Assembly ............................... 21 Figure 10. Unwrapped Vest ................................... 22 Figure 11. Adsorption
Tropical forests are thermally buffered despite intensive selective logging.
Senior, Rebecca A; Hill, Jane K; Benedick, Suzan; Edwards, David P
2018-03-01
Tropical rainforests are subject to extensive degradation by commercial selective logging. Despite pervasive changes to forest structure, selectively logged forests represent vital refugia for global biodiversity. The ability of these forests to buffer temperature-sensitive species from climate warming will be an important determinant of their future conservation value, although this topic remains largely unexplored. Thermal buffering potential is broadly determined by: (i) the difference between the "macroclimate" (climate at a local scale, m to ha) and the "microclimate" (climate at a fine-scale, mm to m, that is distinct from the macroclimate); (ii) thermal stability of microclimates (e.g. variation in daily temperatures); and (iii) the availability of microclimates to organisms. We compared these metrics in undisturbed primary forest and intensively logged forest on Borneo, using thermal images to capture cool microclimates on the surface of the forest floor, and information from dataloggers placed inside deadwood, tree holes and leaf litter. Although major differences in forest structure remained 9-12 years after repeated selective logging, we found that logging activity had very little effect on thermal buffering, in terms of macroclimate and microclimate temperatures, and the overall availability of microclimates. For 1°C warming in the macroclimate, temperature inside deadwood, tree holes and leaf litter warmed slightly more in primary forest than in logged forest, but the effect amounted to <0.1°C difference between forest types. We therefore conclude that selectively logged forests are similar to primary forests in their potential for thermal buffering, and subsequent ability to retain temperature-sensitive species under climate change. Selectively logged forests can play a crucial role in the long-term maintenance of global biodiversity. © 2017 The Authors. Global Change Biology Published by John Wiley & Sons Ltd.
Most scenario‐based climate modeling studies indicate that replacing temperate forest with cropland will promote cooling by reducing surface air temperatures. These results are inconsistent with fieldbased microclimate studies that have found that forests are cooler, wetter, and...
Chapter 10. Dynamics of subalpine forests
Dennis H. Knight
1994-01-01
The boreal owl's fairly specific habitat requirements restrict its range in the conterminous U.S. to subalpine forests (see Chapter 9). These forests provide tree cavities, uncrusted snow that facilitates preying on small mammals, and cool microclimates essential for summer roosting. Such forests also provide habitat for the owl's prey which consists...
Microclimate landscape design at southern integrated terminal Bandar Tasik Selatan, Kuala Lumpur
NASA Astrophysics Data System (ADS)
Phin, L. H.; Krisantia, I.
2018-01-01
Bandar Tasik Selatan is the integrated transport terminal has high energy consuming, high carbon emission and poor linkage. However, microclimate can be reduced through landscape design. This paper is a study to achieve energy efficiency and improve microclimate in the urban area. The research area is at Southern integrated terminal Bandar Tasik Selatan Kuala Lumpur Malaysia. It is carried out through a case study and microclimate analyzed using System Modeling method. System modelling using in this research is system energy budget of the microclimate at a site is a balance between the radiant energy supplied and the energy removed by all consumers. The finding indicated the microclimatic components that can be modified through landscape design are solar radiation, wind and precipitation can create thermal comfort, energy efficiency and others benefits.Through this research, provide more green space to achieve energy efficiency and improve microclimate of the site, introducing vertical landscape and proper planting selection to improve air quality, introducing green energy as part of the source of power supply and to promote integration of terminal building and rail systems by unify them using softscape
NASA Astrophysics Data System (ADS)
Kumar, Ashok; Deoliya, Rajesh; Chani, P. S.
2015-12-01
Green roofs not only provide cooling by shading, but also by transpiration of water through the stomata. However, the evidence for green roofs providing significant air cooling remains limited. No literature investigates the thermal performance of prefab brick panel roofing technology with green roof. Hence, the aim of this research is to investigate the thermal behavior of an experimental room, built at CSIR-Central Building Research Institute (CBRI) campus, Roorkee, India using such roofing technology during May 2013. The study also explores the feasibility of green roof with grass carpets that require minimum irrigation, to assess the expected indoor thermal comfort improvements by doing real-time experimental studies. The results show that the proposed green roof system is suitable for reducing the energy demand for space cooling during hot summer, without worsening the winter energy performance. The cost of proposed retrofit system is about Rs. 1075 per m2. Therefore, green roofs can be used efficiently in retrofitting existing buildings in India to improve the micro-climate on building roofs and roof insulation, where the additional load carrying capacity of buildings is about 100-130 kg/m2.
[To the issue on the optimization and regulation of microclimate in the subway trains and stations].
Leksin, A G; Beresneva, T G; Kaptsov, V A; Korotich, L P; Evlampieva, M N; Timoshenkova, E V
2014-01-01
There is presented an overview of currently existing regulatory framework governing the parameters of the microclimate in the salons of subway passenger cars and stations. Analysis of the normative documents indicated that they contain very incomplete, contradictory, often unfounded information about the parameters of microclimate parameters in salons of subway rolling stock. Also, there are no clear cut hygienically-sound requirements for the work of imposed on the rolling stock subway systems provide microclimate, including new systems for air conditioning and disinfection.
Thermal regimes of Mexican spotted owl nest stands
Joseph L. Ganey
2004-01-01
To evaluate the hypothesis that spotted owls (Strix occidentalis) select habitats with cool microclimates to avoid high daytime temperatures, I sampled thermal regimes in nest areas used by Mexican spotted owls (S. o. lucida) in northern Arizona. I sampled air temperature at 30-min intervals in 30 pairs of nest and random sites...
Operational Characteristics of Four Commercially Available Personal Cooling Vests
NASA Technical Reports Server (NTRS)
Ku, Yu-Tsuan E.; Montgomery, Leslie D.; Lee, Hank C.; Webbon, Bruce W.; Kliss, Mark (Technical Monitor)
1997-01-01
Personal thermoregulatory systems which provide chest cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive and two active cooling vests, and to measure the body temperature and circulatory changes produced by each cooling vest configuration. The MicroClimate Systems and the Life Enhancement Tech(LET) lightweight liquid cooling vests, the Steele Vest and LET's Zipper Front Garment were used to cool the chest region of 11 male and 10 female subjects (25 to 55 yr.) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approx.21 C), were tested for 60 min. with the cooling system operated at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a URI Inc. Biolog ambulatory monitor. In general, the male and female subjects' rectal and ear temperature responses to cooling were similar for all vest configurations tested. Oral temperatures during the recovery period were significantly (P<0.05) lower than during the control period, approx.0.2 - 0.5 C, for both men and women wearing any of the four different garments. The corresponding car temperatures were significantly (P<0.05) decreased approx.0.2 - 0.3 C by the end of the recovery period. Compared to the control period, no significant differences were found in rectal temperatures during cooling and recovery periods. These results show that all vest configurations elicit a similar thermal response in both male and female subject groups. However, subject population variance was rather large and may have masked differences between the vests. One vest may prove more effective than another for a given individual, and experience is the only means of determining this.
NASA Technical Reports Server (NTRS)
Ku, Yu-Tsuan E.; Montgomery, Leslie D.; Lee, Hank C.; Luna, Bernadette; Webbon, Bruce W.; Mead, Susan C. (Technical Monitor)
1999-01-01
Personal cooling systems are widely used in industrial and aerospace environments to alleviate thermal stress. Increasingly they are also used by heat sensitive multiple sclerosis (HSMS) patients to relieve symptoms and improve quality of life. There are a variety of cooling systems commercially available to the MS community. However, little information is available regarding the comparative physiological changes produced by routine operation of these various systems. The objective of this study was to document and compare the patient response to two passive cooling vests and one active cooling garment. The Life Enhancement Technology, Inc. (LET) lightweight active cooling vest with cap, the MicroClimate Systems (MCS) Change of Phase garment, and the Steele Vest were each used to cool 13 male and 13 female MS subjects (31 to 67 yr.) in this study. The subjects, seated in an upright position at normal room temperature (approximately 22 C), were tested with one of the cooling garments. Oral, fight and left ear temperatures were logged manually every 5 min. An-n, leg, chest and rectal temperatures; heart rate; and respiration were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. Each subject was given a series of subjective and objective evaluation tests before and after cooling. The LET and Steele vests test groups had similar, significant (P less than 0.01) cooling effects on oral and ear canal temperature, which decreased approximately 0.4 C, and 0.3 C, respectively. Core temperature increased (N.S.) with all three vests during cooling. The LET vest produced the coldest (P less than 0.01) skin temperature. Overall, the LET vest provided the most improvement on subjective and objective performance measures. These results show that the garment configurations tested do not elicit a similar thermal response in all MS patients. Cooling with the LET active garment configuration resulted in the lowest body temperatures for the MS subjects; cooling with the MCS vest was least effective. For functional responses, the LET test group performed better than the other two vests.
Use of a coverlet system for the management of skin microclimate.
Collier, Mark; Potts, Carol; Shaw, Elaine
2014-08-12
Pressure and shear are the two key extrinsic factors that cause pressure ulcer damage. However, if the resilience of the skin and soft tissue deteriorates, the individual's susceptibility to such pressure damage will increase. The risk is greater if the microclimate at the interface between the skin and the support surface is impaired. This will occur when the skin temperature is elevated and there is excess moisture on the skin surface. Microclimate management therefore plays an important role in pressure ulcer prevention. This article describes how use of a new coverlet system (Skin IQ Microclimate Manager, ArjoHuntleigh) can avoid the accumulation of heat and moisture at the patient/support-surface interface.
Local- and landscape-scale land cover affects microclimate and water use in urban gardens.
Lin, Brenda B; Egerer, Monika H; Liere, Heidi; Jha, Shalene; Bichier, Peter; Philpott, Stacy M
2018-01-01
Urban gardens in Central California are highly vulnerable to the effects of climate change, experiencing both extended high heat periods as well as water restrictions because of severe drought conditions. This puts these critical community-based food production systems at risk as California is expected to experience increasing weather extremes. In agricultural systems, increased vegetation complexity, such as greater structure or biodiversity, can increase the resilience of food production systems from climate fluctuations. We test this theory in 15 urban gardens across California's Central Coast. Local- and landscape-scale measures of ground, vegetation, and land cover were collected in and around each garden, while climate loggers recorded temperatures in each garden in 30min increments. Multivariate analyses, using county as a random factor, show that both local- and landscape-scale factors were important. All factors were significant predictors of mean temperature. Tallest vegetation, tree/shrub species richness, grass cover, mulch cover, and landscape level agricultural cover were cooling factors; in contrast, garden size, garden age, rock cover, herbaceous species richness, and landscape level urban cover were warming factors. Results were similar for the maximum temperature analysis except that agriculture land cover and herbaceous species richness were not significant predictors of maximum temperature. Analysis of gardener watering behavior to observed temperatures shows that garden microclimate was significantly related to the number of minutes watered as well as the number of liters of water used per watering event. Thus gardeners seem to respond to garden microclimate in their watering behavior even though this behavior is most probably motivated by a range of other factors such as water regulations and time availability. This research shows that local management of ground cover and vegetation can reduce mean and maximum temperatures in gardens, and the reduced temperatures may influence watering behavior of gardeners. Crown Copyright © 2017. Published by Elsevier B.V. All rights reserved.
Physiologic Responses Produced by Active and Passive Personal Cooling Vests
NASA Technical Reports Server (NTRS)
Ku, Yu-Tsuan E.; Lee, Hank C.; Montgomery, Leslie D.; Luna, Bernadette
2000-01-01
Personal thermoregulatory systems which provide chest cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to document and compare the subjects' response to three cooling vests in their recommended configurations. The Life Enhancement Tech (LET) lightweight active cooling vest with cap, the MicroClimate Systems Change of Phase garment (MCS), and the Steele Vest were each used to cool the chest regions of 12 male and 8 female Healthy subjects (21 to 69 yr.) in this study. The subjects, seated in an upright position at normal room temperature (approx. 22 C), were tested for 60 min. with one of the cooling garments. The LET active garment had an initial coolant fluid inlet temperature of 60 F, and was ramped down to 50 F. Oral, right and left ear canal temperatures were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; and respiration were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. For men, all three vests had similar, significant cooling effects. Decreases in the average rectal temperature, oral temperature, and ear canal temperatures were approximately 0.2 C, 0.2 C and 0.1 C, respectively. In contrast to the men, the female subjects wearing the MCS and Steel vests had similar cooling responses in which the core temperature remained elevated and oral and ear canal temperatures did not drop. The LET active garment cooled most of the female subjects in this study; rectal, oral and ear temperature decreased about 0.2 C, 0.3 C and 0.3 C, respectively. These results show that the garment configurations tested do not elicit a similar thermal response in all subjects. A gender difference is evident. The LET active garment configuration was most effective in decreasing temperatures of the female subjects; the MCS vest was least effective. For male subjects, the three vests appear to be more nearly equivalent. The active garment system under study included a cooling cap, which may account for some of the difference in response.
Paper birch: Sentinels of climate change in the Niobrara River Valley, Nebraska
Stroh, Esther D.
2011-01-01
The Niobrara River Valley in the northern Great Plains supports scattered stands of paper birch (Betula papyrifera Marsh), a species more typical of boreal forests. These birch stands are considered to be relictual populations that have persisted since the end of the Wisconsin glaciation. Localized summer microclimates have likely facilitated the persistence of birch populations in a region otherwise unsuitable for the species. Dieback of canopy-sized birch has been observed throughout the valley in recent years, although no onset dates are documented. Changes in spring weather patterns may be causing rootlet injury so that trees die in spite of the still-cool summer microclimates. Current weather patterns, combined with little evidence of recruitment of young birch and great geographic distances from potential immigrant sources, make the future persistence of birch in the Niobrara River Valley stands uncertain.
Comparison of Microclimate Simulated weather data to ASHRAE Clear Sky Model and Measured Data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bhandari, Mahabir S.
In anticipation of emerging global urbanization and its impact on microclimate, a need exists to better understand and quantify microclimate effects on building energy use. Satisfaction of this need will require coordinated research of microclimate impacts on and from “human systems.” The Urban Microclimate and Energy Tool (Urban-MET) project seeks to address this need by quantifying and analyzing the relationships among climatic conditions, urban morphology, land cover, and energy use; and using these relationships to inform energy-efficient urban development and planning. Initial research will focus on analysis of measured and modeled energy efficiency of various building types in selected urbanmore » areas and temporal variations in energy use for different urban morphologies under different microclimatic conditions. In this report, we analyze the differences between microclimate weather data sets for the Oak Ridge National Laboratory campus produced by ENVI-met and Weather Research Forecast (WRF) models, the ASHRAE clear sky which defines the maximum amounts of solar radiation that can be expected, and measured data from a weather station on campus. Errors with climate variables and their impact on building energy consumption will be shown for the microclimate simulations to help prioritize future improvement for use in microclimate simulation impacts to energy use of buildings.« less
Army Field-Oriented S&T Experimentation Venues: A Comparative Analysis
2011-09-01
Microclimate Cooling Station (MCCS)). The Fort Benning AEWE provides the venue and the data collection and analysis. The costs to the S&T...forest, fields, etc.) and is designated as an Army experimental station with access to ground and an aerial fleet. Technology developers have optional...YTC), (2) tropical (the Tropic Regions Test Center, Panama Canal Zone), and (3) cold weather (CRTC, Bolio Lake Test Complex, AK. Special
[Effects of land use type on diurnal dynamics of environment microclimate in Karst zone].
Li, Sheng; Ren, Hua-Dong; Yao, Xiao-Hua; Zhang, Shou-Gong
2009-02-01
In June 2007, the diurnal dynamics of light intensity, air temperature, air relative humidity, soil temperature, and surface soil (0-5 cm) water content of five land use types in the typical Karst zone of Lingyun City in Guangxi Zhuang Autonomous Region were observed. The results showed that different land use types altered the composition, coverage, and height of aboveground vegetation, which in turn changed the environment microclimate to different degree. The microclimate quality was in the order of forestland > shrub land > grassland > farmland > rock land. On rock land, the light intensity, air temperature, air relative humidity, soil temperature, and soil water content were higher, and the diurnal variation of the five climatic factors was notable, with the microclimatic conditions changed towards drier and hotter. Compared with those on rock land, the light intensity on forestland, shrub land, grassland, and farmland decreased by 96.4%, 52.0%, 17.0% and 44.2%, air temperature decreased by 30.1%, 20.2%, 12.7% and 17.8%, air relative humidity increased by 129.2%, 57.2%, 18.0% and 41.2%, soil temperature decreased by 11.5%, 8%, 2.5% and 5.5%, and soil water content increased by 42.6%, 33.2%, 15.7% and 14.0%, respectively. The five climatic factors on forestland and shrub land had lesser fluctuation, with the microclimate tended to cool and wet. Light intensity, air temperature, and soil temperature correlated positively with each other, and had negative correlations with air relative humidity and soil water content. A positive correlation was observed between air temperature and soil water content.
The Importance of Biologically Relevant Microclimates in Habitat Suitability Assessments
Varner, Johanna; Dearing, M. Denise
2014-01-01
Predicting habitat suitability under climate change is vital to conserving biodiversity. However, current species distribution models rely on coarse scale climate data, whereas fine scale microclimate data may be necessary to assess habitat suitability and generate predictive models. Here, we evaluate disparities between temperature data at the coarse scale from weather stations versus fine-scale data measured in microhabitats required for a climate-sensitive mammal, the American pika (Ochotona princeps). We collected two years of temperature data in occupied talus habitats predicted to be suitable (high elevation) and unsuitable (low elevation) by the bioclimatic envelope approach. At low elevations, talus surface and interstitial microclimates drastically differed from ambient temperatures measured on-site and at a nearby weather station. Interstitial talus temperatures were frequently decoupled from high ambient temperatures, resulting in instantaneous disparities of over 30°C between these two measurements. Microhabitat temperatures were also highly heterogeneous, such that temperature measurements within the same patch of talus were not more correlated than measurements at distant patches. An experimental manipulation revealed that vegetation cover may cool the talus surface by up to 10°C during the summer, which may contribute to this spatial heterogeneity. Finally, low elevation microclimates were milder and less variable than typical alpine habitat, suggesting that, counter to species distribution model predictions, these seemingly unsuitable habitats may actually be better refugia for this species under climate change. These results highlight the importance of fine-scale microhabitat data in habitat assessments and underscore the notion that some critical refugia may be counterintuitive. PMID:25115894
Zeevi, Tal; Levy, Ayelet; Brauner, Neima; Gefen, Amit
2018-06-01
Scientific evidence regarding microclimate and its effects on the risk of pressure ulcers (PU) remains sparse. It is known that elevated skin temperatures and moisture may affect metabolic demand as well as the mechanical behaviour of the tissue. In this study, we incorporated these microclimate factors into a novel, 3-dimensional multi-physics coupled model of the human buttocks, which simultaneously determines the biothermal and biomechanical behaviours of the buttocks in supine lying on different support surfaces. We compared 3 simulated thermally controlled mattresses with 2 reference foam mattresses. A tissue damage score was numerically calculated in a relevant volume of the model, and the cooling effect of each 1°C decrease of tissue temperature was deduced. Damage scores of tissues were substantially lower for the non-foam mattresses compared with the foams. The percentage tissue volume at risk within the volume of interest was found to grow exponentially as the average tissue temperature increased. The resultant average sacral skin temperature was concluded to be a good predictor for an increased risk of PU/injuries. Each 1°C increase contributes approximately 14 times as much to the risk with respect to an increase of 1 mmHg of pressure. These findings highlight the advantages of using thermally controlled support surfaces as well as the need to further assess the potential damage that may be caused by uncontrolled microclimate conditions on inadequate support surfaces in at-risk patients. © 2017 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
The importance of biologically relevant microclimates in habitat suitability assessments.
Varner, Johanna; Dearing, M Denise
2014-01-01
Predicting habitat suitability under climate change is vital to conserving biodiversity. However, current species distribution models rely on coarse scale climate data, whereas fine scale microclimate data may be necessary to assess habitat suitability and generate predictive models. Here, we evaluate disparities between temperature data at the coarse scale from weather stations versus fine-scale data measured in microhabitats required for a climate-sensitive mammal, the American pika (Ochotona princeps). We collected two years of temperature data in occupied talus habitats predicted to be suitable (high elevation) and unsuitable (low elevation) by the bioclimatic envelope approach. At low elevations, talus surface and interstitial microclimates drastically differed from ambient temperatures measured on-site and at a nearby weather station. Interstitial talus temperatures were frequently decoupled from high ambient temperatures, resulting in instantaneous disparities of over 30 °C between these two measurements. Microhabitat temperatures were also highly heterogeneous, such that temperature measurements within the same patch of talus were not more correlated than measurements at distant patches. An experimental manipulation revealed that vegetation cover may cool the talus surface by up to 10 °C during the summer, which may contribute to this spatial heterogeneity. Finally, low elevation microclimates were milder and less variable than typical alpine habitat, suggesting that, counter to species distribution model predictions, these seemingly unsuitable habitats may actually be better refugia for this species under climate change. These results highlight the importance of fine-scale microhabitat data in habitat assessments and underscore the notion that some critical refugia may be counterintuitive.
Spatial models reveal the microclimatic buffering capacity of old-growth forests
Frey, Sarah J. K.; Hadley, Adam S.; Johnson, Sherri L.; Schulze, Mark; Jones, Julia A.; Betts, Matthew G.
2016-01-01
Climate change is predicted to cause widespread declines in biodiversity, but these predictions are derived from coarse-resolution climate models applied at global scales. Such models lack the capacity to incorporate microclimate variability, which is critical to biodiversity microrefugia. In forested montane regions, microclimate is thought to be influenced by combined effects of elevation, microtopography, and vegetation, but their relative effects at fine spatial scales are poorly known. We used boosted regression trees to model the spatial distribution of fine-scale, under-canopy air temperatures in mountainous terrain. Spatial models predicted observed independent test data well (r = 0.87). As expected, elevation strongly predicted temperatures, but vegetation and microtopography also exerted critical effects. Old-growth vegetation characteristics, measured using LiDAR (light detection and ranging), appeared to have an insulating effect; maximum spring monthly temperatures decreased by 2.5°C across the observed gradient in old-growth structure. These cooling effects across a gradient in forest structure are of similar magnitude to 50-year forecasts of the Intergovernmental Panel on Climate Change and therefore have the potential to mitigate climate warming at local scales. Management strategies to conserve old-growth characteristics and to curb current rates of primary forest loss could maintain microrefugia, enhancing biodiversity persistence in mountainous systems under climate warming. PMID:27152339
Spatial models reveal the microclimatic buffering capacity of old-growth forests.
Frey, Sarah J K; Hadley, Adam S; Johnson, Sherri L; Schulze, Mark; Jones, Julia A; Betts, Matthew G
2016-04-01
Climate change is predicted to cause widespread declines in biodiversity, but these predictions are derived from coarse-resolution climate models applied at global scales. Such models lack the capacity to incorporate microclimate variability, which is critical to biodiversity microrefugia. In forested montane regions, microclimate is thought to be influenced by combined effects of elevation, microtopography, and vegetation, but their relative effects at fine spatial scales are poorly known. We used boosted regression trees to model the spatial distribution of fine-scale, under-canopy air temperatures in mountainous terrain. Spatial models predicted observed independent test data well (r = 0.87). As expected, elevation strongly predicted temperatures, but vegetation and microtopography also exerted critical effects. Old-growth vegetation characteristics, measured using LiDAR (light detection and ranging), appeared to have an insulating effect; maximum spring monthly temperatures decreased by 2.5°C across the observed gradient in old-growth structure. These cooling effects across a gradient in forest structure are of similar magnitude to 50-year forecasts of the Intergovernmental Panel on Climate Change and therefore have the potential to mitigate climate warming at local scales. Management strategies to conserve old-growth characteristics and to curb current rates of primary forest loss could maintain microrefugia, enhancing biodiversity persistence in mountainous systems under climate warming.
[A review on the urban green space cooling effect based on field measurement of air temperature].
Liu, Feng Feng; Yan, Wei Jiao; Kong, Fan Hua; Yin, Hai Wei; Ban, Yu Long; Xu, Wen Bin
2017-04-18
With the development of urbanization, the effect of urban heat island has become increasingly evident. As an essential component of the urban natural landscapes, urban green space plays an important role in mitigating the effect of urban heat island. However, facing the rapid urbanization and changing environment, how to rationally plan and design the green space and realize its best cooling effect which can improve the urban environment and microclimate is still an urgent problem to be solved. So there is a strong need for mulitiscale researches on the cooling effect of urban green space. This paper systematically gave a review on the cooling effect of urban green space based on field measurement of air temperature, the main factors that influenced the cooling effect of green space were explored from three aspects including the area and shape characteristics of urban green space, the structure characteristics of vegetation and the external factors which affected the cooling effect, and the characteristics of the cooling effect of the green space were summarized from the aspect of time variation and distance decay. Then, the main problems and future research prospects of urban green space cooling effect were put forward.
Ardia, Daniel R; Pérez, Jonathan H; Clotfelter, Ethan D
2010-06-22
Nest microclimate can have strong effects that can carry over to later life-history stages. We experimentally cooled the nests of tree swallows (Tachycineta bicolor). Females incubating in cooled nests reduced incubation time and allowed egg temperatures to drop, leading to extended incubation periods. We partially cross-fostered nestlings to test carry-over effects of cooling during incubation on nestling innate constitutive immunity, assessed through bacteria killing ability (BKA) of blood. Nestlings that had been cooled as eggs showed a lower ability to kill bacteria than control nestlings, regardless of the treatment of their foster mother. However, there was no effect of treatment of rearing females on nestling BKA in control nestlings, even though cooled females made significantly fewer feeding visits than did control females. This suggests that the effect of cooling occurred during incubation and was not due to carry-over effects on nestling condition. Nestlings that were exposed to experimental cooling as embryos had lower residual body mass and absolute body mass at all four ages measured. Our results indicate that environmental conditions and trade-offs experienced during one stage of development can have important carry-over effects on later life-history stages.
NASA Astrophysics Data System (ADS)
Yahia, Moohammed Wasim; Johansson, Erik; Thorsson, Sofia; Lindberg, Fredrik; Rasmussen, Maria Isabel
2018-03-01
Due to the complexity of built environment, urban design patterns considerably affect the microclimate and outdoor thermal comfort in a given urban morphology. Variables such as building heights and orientations, spaces between buildings, plot coverage alter solar access, wind speed and direction at street level. To improve microclimate and comfort conditions urban design elements including vegetation and shading devices can be used. In warm-humid Dar es Salaam, the climate consideration in urban design has received little attention although the urban planning authorities try to develop the quality of planning and design. The main aim of this study is to investigate the relationship between urban design, urban microclimate, and outdoor comfort in four built-up areas with different morphologies including low-, medium-, and high-rise buildings. The study mainly concentrates on the warm season but a comparison with the thermal comfort conditions in the cool season is made for one of the areas. Air temperature, wind speed, mean radiant temperature (MRT), and the physiologically equivalent temperature (PET) are simulated using ENVI-met to highlight the strengths and weaknesses of the existing urban design. An analysis of the distribution of MRT in the areas showed that the area with low-rise buildings had the highest frequency of high MRTs and the lowest frequency of low MRTs. The study illustrates that areas with low-rise buildings lead to more stressful urban spaces than areas with high-rise buildings. It is also shown that the use of dense trees helps to enhance the thermal comfort conditions, i.e., reduce heat stress. However, vegetation might negatively affect the wind ventilation. Nevertheless, a sensitivity analysis shows that the provision of shade is a more efficient way to reduce PET than increases in wind speed, given the prevailing sun and wind conditions in Dar es Salaam. To mitigate heat stress in Dar es Salaam, a set of recommendations and guidelines on how to develop the existing situation from microclimate and thermal comfort perspectives is outlined. Such recommendations will help architects and urban designers to increase the quality of the outdoor environment and demonstrate the need to create better urban spaces in harmony with microclimate and thermal comfort.
Yahia, Moohammed Wasim; Johansson, Erik; Thorsson, Sofia; Lindberg, Fredrik; Rasmussen, Maria Isabel
2018-03-01
Due to the complexity of built environment, urban design patterns considerably affect the microclimate and outdoor thermal comfort in a given urban morphology. Variables such as building heights and orientations, spaces between buildings, plot coverage alter solar access, wind speed and direction at street level. To improve microclimate and comfort conditions urban design elements including vegetation and shading devices can be used. In warm-humid Dar es Salaam, the climate consideration in urban design has received little attention although the urban planning authorities try to develop the quality of planning and design. The main aim of this study is to investigate the relationship between urban design, urban microclimate, and outdoor comfort in four built-up areas with different morphologies including low-, medium-, and high-rise buildings. The study mainly concentrates on the warm season but a comparison with the thermal comfort conditions in the cool season is made for one of the areas. Air temperature, wind speed, mean radiant temperature (MRT), and the physiologically equivalent temperature (PET) are simulated using ENVI-met to highlight the strengths and weaknesses of the existing urban design. An analysis of the distribution of MRT in the areas showed that the area with low-rise buildings had the highest frequency of high MRTs and the lowest frequency of low MRTs. The study illustrates that areas with low-rise buildings lead to more stressful urban spaces than areas with high-rise buildings. It is also shown that the use of dense trees helps to enhance the thermal comfort conditions, i.e., reduce heat stress. However, vegetation might negatively affect the wind ventilation. Nevertheless, a sensitivity analysis shows that the provision of shade is a more efficient way to reduce PET than increases in wind speed, given the prevailing sun and wind conditions in Dar es Salaam. To mitigate heat stress in Dar es Salaam, a set of recommendations and guidelines on how to develop the existing situation from microclimate and thermal comfort perspectives is outlined. Such recommendations will help architects and urban designers to increase the quality of the outdoor environment and demonstrate the need to create better urban spaces in harmony with microclimate and thermal comfort.
Pan, D; Chan, M; Deng, S; Xia, L; Xu, X
2011-11-01
This article reports on two numerical studies on the microclimate around, and the thermal neutrality of, a sleeping person in a space installed with a displacement ventilation system. The development of a sleeping computational thermal manikin (SCTM) placed in a space air-conditioned by a displacement ventilation system is first described. This is followed by reporting the results of the first numerical study on the microclimate around the SCTM, including air temperature and velocity distributions and the heat transfer characteristics. Then the outcomes of the other numerical study on the thermal neutrality of a sleeping person are presented, including the thermal neutrality for a naked sleeping person and the effects of the total insulation value of a bedding system on the thermal neutrality of a sleeping person. STATEMENT OF RELEVANCE: The thermal environment would greatly affect the sleep quality of human beings. Through developing a SCTM, the microclimate around a sleeping person has been numerically studied. The thermal neutral environment may then be predicted and contributions to improved sleep quality may be made.
NASA Astrophysics Data System (ADS)
Haque, N.; Singh, M.; Hossain, S. A.
2016-12-01
The present study was aimed at determining changes in milk yield and composition along with the plasminogen-plasmin system of milk, plasma hormones, and metabolites of buffaloes during hot dry season (air temperature range 39.7 to 44.8 °C) under two different management systems. Buffaloes were divided in two groups of six animals each: control and treatment, where treatment group animals accessed benefit of mist and fan cooling from 9:30 a.m. to 5:00 p.m., while control group animals were devoid of it. Duration of experiment was 6 weeks. Under mist and fan cooling system, buffaloes experienced better comfort by alleviating environmental stress as their physiological responses such as rectal temperature, respiration rate, pulse rate, and forehead and middorsal temperatures were significantly ( P < 0.05) reduced compared to control, which subsequently resulted higher milk yield by 4.44 % ( P < 0.001). Analysis of milk samples revealed higher concentration of plasminogen (7.99 vs 6.27 μg/ml; P < 0.01) and β-casein (1.09 vs 0.92 g/dl; P < 0.001) and lower plasmin level (0.178 vs 0.194 μg/ml; P < 0.05) in buffaloes under the treatment group compared to that under the control. Plasma glucose level was higher ( P < 0.001) by 21.08 %, whereas cortisol, norepinephrine, and NEFA levels were lower ( P < 0.001) by 19.19, 15.38, and 11.41 %, respectively, in treatment animals. However, exposure of buffaloes to cooling system did not alter composition and calcium content of milk, GH, and epinephrine level in plasma. Hence, it may be concluded that provision of cooling system during summer was effective to minimize environmental stress and improve milk production by manipulation of the PG-PL system in buffaloes.
Haque, N; Singh, M; Hossain, S A
2016-12-01
The present study was aimed at determining changes in milk yield and composition along with the plasminogen-plasmin system of milk, plasma hormones, and metabolites of buffaloes during hot dry season (air temperature range 39.7 to 44.8 °C) under two different management systems. Buffaloes were divided in two groups of six animals each: control and treatment, where treatment group animals accessed benefit of mist and fan cooling from 9:30 a.m. to 5:00 p.m., while control group animals were devoid of it. Duration of experiment was 6 weeks. Under mist and fan cooling system, buffaloes experienced better comfort by alleviating environmental stress as their physiological responses such as rectal temperature, respiration rate, pulse rate, and forehead and middorsal temperatures were significantly (P < 0.05) reduced compared to control, which subsequently resulted higher milk yield by 4.44 % (P < 0.001). Analysis of milk samples revealed higher concentration of plasminogen (7.99 vs 6.27 μg/ml; P < 0.01) and β-casein (1.09 vs 0.92 g/dl; P < 0.001) and lower plasmin level (0.178 vs 0.194 μg/ml; P < 0.05) in buffaloes under the treatment group compared to that under the control. Plasma glucose level was higher (P < 0.001) by 21.08 %, whereas cortisol, norepinephrine, and NEFA levels were lower (P < 0.001) by 19.19, 15.38, and 11.41 %, respectively, in treatment animals. However, exposure of buffaloes to cooling system did not alter composition and calcium content of milk, GH, and epinephrine level in plasma. Hence, it may be concluded that provision of cooling system during summer was effective to minimize environmental stress and improve milk production by manipulation of the PG-PL system in buffaloes.
Shimazaki, Yasuhiro; Matsutani, Toshiki; Satsumoto, Yayoi
2016-07-01
Comfort is an important concept in footwear design. The microclimate inside footwear contributes to the perception of thermal comfort. To investigate the effect of ventilation on microclimate formation inside footwear, experiments with subjects were conducted at four gait speeds with three different footwear sizes. Skin temperature, metabolism, and body mass were measured at approximately 25 °C and 50% relative humidity, with no solar radiation and a calm wind. The footwear occupancy and ventilation rate were also estimated, with the latter determined using the tracer gas method. The experimental results revealed that foot movement, metabolism, evaporation, radiation, convection, and ventilation were the main factors influencing the energy balance for temperature formation on the surface of the foot. The cooling effect of ventilation on the arch temperature was observed during gait. The significance of the amount of air space and ventilation on the improvement in the thermal comfort of footwear was clarified. Copyright © 2015 Elsevier Ltd and The Ergonomics Society. All rights reserved.
Concerning modeling of double-stage water evaporation cooling
NASA Astrophysics Data System (ADS)
Shatskiy, V. P.; Fedulova, L. I.; Gridneva, I. V.
2018-03-01
The matter of need for setting technical norms for production, as well as acceptable microclimate parameters, such as temperature and humidity, at the work place, remains urgent. Use of certain units should be economically sound and that should be taken into account for construction, assembly, operation, technological, and environmental requirements. Water evaporation coolers are simple to maintain, environmentally friendly, and quite cheap, but the development of the most efficient solutions requires mathematical modeling of the heat and mass transfer processes that take place in them.
1992-08-01
including instrumenting and dressing the subjects, monitoring the physiological parameters in the simulator, and collecting and processing data. They...also was decided to extend the recruiting process to include all helicopter aviators, even if not UH-60 qualified. There is little in the flight profile...parameter channels, and the data were processed to produce a single root mean square (RMS) error value for each channel appropriate to each of the 9
NASA Astrophysics Data System (ADS)
Karvatte, Nivaldo; Klosowski, Elcio Silvério; de Almeida, Roberto Giolo; Mesquita, Eduardo Eustáquio; de Oliveira, Caroline Carvalho; Alves, Fabiana Villa
2016-12-01
The objective of this paper was to perform a microclimate evaluation and determine the indexes of thermal comfort indexes, in sun and shade, in integrated crop-livestock-forest systems with different arrangements of eucalyptus and native trees, in the Brazilian Midwest. The experiment was conducted at Embrapa Beef Cattle in Campo Grande, state of Mato Grosso do Sul, Brazil, from July to September 2013. The evaluations were conducted on four consecutive days, from 8:00 a.m. to 5:00 p.m., local time (GMT -4:00), with 1 hour intervals, recording the microclimate parameters: air temperature (°C), black globe temperature (°C), wet bulb temperature (°C), relative humidity (%), and wind speed (m.s-1), for the subsequent calculation of the Temperature and Humidity Index, the Black Globe Temperature and Humidity Index, and the Radiant Thermal Load. The largest changes in microclimate parameters were found in the full sun, between 12:00 p.m. and 1:00 p.m., in less dense eucalyptus system, followed by the scattered native trees system, resulting in a maximum Temperature and Humidity Index of 81, Black Globe Temperature and Humidity Index of 88 and Radiant Thermal Load of 794 W m-2. Therefore, it is observed that with the presence of trees in pastures were possible reductions of up to 3.7 % in Temperature and Humidity Index, 10.2 % in the Black Globe Temperature and Humidity Index, and 28.3 % of the Radiant Thermal Load in the shade. Thus, one can conclude that the presence of trees and their arrangement in the systems provide better microclimate conditions and animal thermal comfort in pastures.
Karvatte, Nivaldo; Klosowski, Elcio Silvério; de Almeida, Roberto Giolo; Mesquita, Eduardo Eustáquio; de Oliveira, Caroline Carvalho; Alves, Fabiana Villa
2016-12-01
The objective of this paper was to perform a microclimate evaluation and determine the indexes of thermal comfort indexes, in sun and shade, in integrated crop-livestock-forest systems with different arrangements of eucalyptus and native trees, in the Brazilian Midwest. The experiment was conducted at Embrapa Beef Cattle in Campo Grande, state of Mato Grosso do Sul, Brazil, from July to September 2013. The evaluations were conducted on four consecutive days, from 8:00 a.m. to 5:00 p.m., local time (GMT -4:00), with 1 hour intervals, recording the microclimate parameters: air temperature (°C), black globe temperature (°C), wet bulb temperature (°C), relative humidity (%), and wind speed (m.s -1 ), for the subsequent calculation of the Temperature and Humidity Index, the Black Globe Temperature and Humidity Index, and the Radiant Thermal Load. The largest changes in microclimate parameters were found in the full sun, between 12:00 p.m. and 1:00 p.m., in less dense eucalyptus system, followed by the scattered native trees system, resulting in a maximum Temperature and Humidity Index of 81, Black Globe Temperature and Humidity Index of 88 and Radiant Thermal Load of 794 W m -2 . Therefore, it is observed that with the presence of trees in pastures were possible reductions of up to 3.7 % in Temperature and Humidity Index, 10.2 % in the Black Globe Temperature and Humidity Index, and 28.3 % of the Radiant Thermal Load in the shade. Thus, one can conclude that the presence of trees and their arrangement in the systems provide better microclimate conditions and animal thermal comfort in pastures.
USDA-ARS?s Scientific Manuscript database
Soil and irrigation management have been used to optimize crop production. However,their effects on microclimate, development, and controls of potato diseases have not been adequately quantified. The effects of soil, crop, and water management on development of potato early blight and late blight we...
NASA Astrophysics Data System (ADS)
Finaeva, O.
2017-11-01
The article represents a brief analysis of factors that influence the development of an urban green space system: territorial and climatic conditions, cultural and historical background as well as the modern strategy of historic cities development. The introduction defines the concept of urban greening, green spaces and green space distribution. The environmental parameters influenced by green spaces are determined. By the example of Italian cities the principles of the urban greening system development are considered: the historical aspects of formation of the urban greening system in Italian cities are analyzed, the role of green spaces in the formation of the urban environment structure and the creation of a favorable microclimate is determined, and a set of measures aimed at its improvement is highlighted. The modern principles of urban greening systems development and their characteristic features are considered. Special attention is paid to the interrelation of architectural and green structures in the formation of a favorable microclimate and psychological comfort in the urban environment; various methods of greening are considered by the example of existing architectural complexes depending on the climate of the area and the landscape features. The examples for the choice of plants and the application of compositional techniques are given. The results represent the basic principles of developing an urban green spaces system. The conclusion summarizes the techniques aimed at the microclimate improvement in the urban environment.
NASA Astrophysics Data System (ADS)
Ahmed, Abdullahi; Mateo-Garcia, Monica; McGough, Danny; Caratella, Kassim; Ure, Zafer
2018-02-01
Indoor Environmental Quality (IEQ) is essential for the health and productivity of building users. The risk of overheating in buildings is increasing due to increased density of occupancy of people and heat emitting equipment, increase in ambient temperature due to manifestation of climate change or changes in urban micro-climate. One of the solutions to building overheating is to inject some exposed thermal mass into the interior of the building. There are many different types of thermal storage materials which typically includes sensible heat storage materials such as concrete, bricks, rocks etc. It is very difficult to increase the thermal mass of existing buildings using these sensible heat storage materials. Alternative to these, there are latent heat storage materials called Phase Change Materials (PCM), which have high thermal storage capacity per unit volume of materials making them easy to implement within retrofit project. The use of Passive Cooling Thermal Energy Storage (TES) systems in the form of PCM PlusICE Solutions has been investigated in occupied spaces to improve indoor environmental quality. The work has been carried out using experimental set-up in existing spaces and monitored through the summer the months. The rooms have been monitored using wireless temperature and humidity sensors. There appears to be significant improvement in indoor temperature of up to 5°K in the room with the PCM compared to the monitored control spaces. The success of PCM for passive cooling is strongly dependent on the ventilation strategy employed in the spaces. The use of night time cooling to purge the stored thermal energy is essential for improved efficacy of the systems to reduce overheating in the spaces. The investigation is carried within the EU funded RESEEPEE project.
Raman spectroscopy detection of biomolecules in biocrusts from differing environmental conditions
NASA Astrophysics Data System (ADS)
Miralles, I.; Jorge-Villar, S. E.; van Wesemael, B.; Lázaro, R.
2017-01-01
Lichens and cyanobacteria colonize inhospitable places covering a wide climate range due to their different survival strategies, such as the synthesis of protective biomolecules. The effect of ecological factors on the synthesis of biomolecules has not been widely analysed. This study aimed to assess the effects of four factors (species, microclimate, seasonality and hydration state) and their interactions on the biomolecule frequency detected by Raman Spectroscopy. We included cyanobacterial biocrusts, and the lichens Diploschistes diacapsis, Squamarina lentigera, and Lepraria isidiata; two contrasted microclimates (typical and marginal), two contrasted seasons (hot and dry vs cool and wet) and two hydration states (dry and wet). ;Species; was the most influential factor in the identity and frequency of the main biomolecules. Microclimatic differences in the range of the local specific habitats only influenced the biomolecules in cyanobacteria. There was a quadruple interaction among the factors, the effects being different mainly depending on the species. At D. diacapsis, the production of their main biomolecules depended on microclimate, although it also depended on seasonality. Nevertheless, in L. isidiata and S. lentigera microclimatic differences did not significantly affect the production of biomolecules. In the lichen species, the microhabitats exposed to relatively larger incident radiation did not show significantly larger relative frequency of photoprotective biomolecules. No clear connection between higher production of oxalates and drier microhabitats was found, suggesting that the synthesis of oxalates is not related to water reserve strategy. The pros and cons of monitor biomolecules in biocrust by Raman spectrometry were also discussed.
USDA-ARS?s Scientific Manuscript database
Soil and irrigation management have been used to optimize crop production; however,their effects on microclimate, development, and potato diseases have not been adequately quantified. The effects of soil, crop, and water management on development of potato early blight and late blight were quantifie...
Analyzing the Efficiency of Introduction of the Intermittent Heating Mode
NASA Astrophysics Data System (ADS)
Anisimova, E.; Shcherbak, A.
2017-11-01
The efficiency of introduction of an optimal intermittent heating mode for a service center building in Chelyabinsk is estimated. The optimal intermittent heating mode ensures heat energy saving while maintaining the required microclimate parameters. The graphical dependencies of the amount of heat energy saving on the heat retention of the building and the outdoor air temperature are shown. The fundamental formulas which were the basis for calculating the periods of cooling, warming and expenditures of heat energy for the two heating modes are given. The literature on the issue is reviewed, the main points, advantages and disadvantages in the works of both Russian and foreign authors are revealed. The calculation was carried out in compliance with the modern state standards and regulatory documents. The capital costs of a system construction with an intermittent heating mode are determined.
NASA Astrophysics Data System (ADS)
Stelling, Jonathan M.; Yu, Zicheng; Loisel, Julie; Beilman, David W.
2018-05-01
The western Antarctic Peninsula experienced rapid warming in the second half of the 20th century, which has increased vascular plant abundance and moss productivity. To better understand long-term ecological responses, we used paleoecological and microclimate data to investigate dynamics of late-Holocene peatbank development and landscape influences. In peatbank cores from three locations on Litchfield Island (64°46‧S; 64°06‧W) high-resolution plant macrofossil and geochemical analysis show contrasting ecological and environmental changes. Two peatbanks on the southwest- and west-facing slopes of two separate hills are about 500 years old in contrast to a north-facing peatbank that is 2700 years old. The period from 1350 to 450 calibrated years before present (cal yr BP) at the north-facing peatbank had low accumulation (0.25 mm yr-1, 36 g OM m-2 yr-1), which we interpret as a period of low temperature and increased snow cover. Microclimate differences were amplified by this regional climate cooling, causing the delayed peat initiation on non-equator-facing slopes. Over the last 500 years, the north-facing peatbank had an accumulation rate (0.7 mm yr-1, 76 g OM m-2 yr-1) that was lower than the southwest- and west-facing peatbanks (1-1.4 mm yr-1, 97-110 g OM m-2 yr-1). Microclimate data suggest that slope aspect on Litchfield Island influences soil temperature, snow cover, and water availability that in turn affect growing-season lengths and peat accumulation. Plant macrofossils preserved in the north- and west-facing peatbanks show a centennial-scale pattern of fluctuation in relative abundance of dry-adapted Polytrichum strictum and wetter Chorisodontium aciphyllum mosses. Our results suggest that moss communities responded to external environmental influence, particularly those affecting moisture conditions, while topography and resultant microclimate differences had a strong influence on peat accumulation.
Microclimate Cooling and the Aircrew Chemical Defense Ensemble
1986-05-01
subjects on approximately 50 percent of the ZITA test trials in order to increase the subjects workload. The 11 tititett^^ ZITA was administered...included the standard deviations of vertical airspeed (VSI) and aircraft roll (ROLL). Time on trial was not measured in this 3 £3 22...34.■ " - ".* V "> "«"> * » "J * -"«" * * s *JI ’ • v« » .^ .’ VBJ-JI ’^M^M M* rafruilWAXrj|"J(AJir^Alinjrrwrwr»..rwrru<rBfrwrrir.. only HAAT trials with
Energy saving by using natural energy from the shallow ground depths - many years operating results
NASA Astrophysics Data System (ADS)
Besler, Maciej; Skrzycki, Maciej; Cepiński, Wojciech
2017-11-01
We pay back more and more larger attention on solutions which saving energy produced from conventional fuels. This is possible to obtainment in significant quantities in fields in which use up the large quantities of energy. The formation the microclimate of interiors is an example of such situation. Especially in the case air conditioning, heating and mechanical ventilation. There is, however, a possibility of energy saving as well as considerable reducing the pollution coming from combustion of raw materials by utilising the natural renewable energy from the shallow ground. In the paper the results gained during several year of continuous measurement on the exchanger were presented. In summer periods an air cooling occurs 10-12 K, e. g. from +30 °C to +20 °C. In winter on the other hand, a preparatory preheating of the air is possible, e.g. from-18°C to about ± 0°C. It is then possible to obtain for the air conditioning system the total energy needed for cooling purposes at the summer periods, or up to 50% of the ventilation heat energy in winter picks.
Lenzholzer, Sanda
2010-03-01
Acceptance of public spaces is often guided by perceptual schemata. Such schemata also seem to play a role in thermal comfort and microclimate experience. For climate-responsive design with a focus on thermal comfort it is important to acquire knowledge about these schemata. For this purpose, perceived and "real" microclimate situations were compared for three Dutch urban squares. People were asked about their long-term microclimate perceptions, which resulted in "cognitive microclimate maps". These were compared with mapped microclimate data from measurements representing the common microclimate when people stay outdoors. The comparison revealed some unexpected low matches; people clearly overestimated the influence of the wind. Therefore, a second assumption was developed: that it is the more salient wind situations that become engrained in people's memory. A comparison using measurement data from windy days shows better matches. This suggests that these more salient situations play a role in the microclimate schemata that people develop about urban places. The consequences from this study for urban design are twofold. Firstly, urban design should address not only the "real" problems, but, more prominently, the "perceived" problems. Secondly, microclimate simulations addressing thermal comfort issues in urban spaces should focus on these perceived, salient situations.
Tree structure and cavity microclimate: implications for bats and birds.
Clement, Matthew J; Castleberry, Steven B
2013-05-01
It is widely assumed that tree cavity structure and microclimate affect cavity selection and use in cavity-dwelling bats and birds. Despite the interest in tree structure and microclimate, the relationship between the two has rarely been quantified. Currently available data often comes from artificial structures that may not accurately represent conditions in natural cavities. We collected data on tree cavity structure and microclimate from 45 trees in five cypress-gum swamps in the Coastal Plain of Georgia in the United States in 2008. We used hierarchical linear models to predict cavity microclimate from tree structure and ambient temperature and humidity, and used Aikaike's information criterion to select the most parsimonious models. We found large differences in microclimate among trees, but tree structure variables explained <28% of the variation, while ambient conditions explained >80% of variation common to all trees. We argue that the determinants of microclimate are complex and multidimensional, and therefore cavity microclimate cannot be deduced easily from simple tree structures. Furthermore, we found that daily fluctuations in ambient conditions strongly affect microclimate, indicating that greater weather fluctuations will cause greater differences among tree cavities.
Raman spectroscopy detection of biomolecules in biocrusts from differing environmental conditions.
Miralles, I; Jorge-Villar, S E; van Wesemael, B; Lázaro, R
2017-01-15
Lichens and cyanobacteria colonize inhospitable places covering a wide climate range due to their different survival strategies, such as the synthesis of protective biomolecules. The effect of ecological factors on the synthesis of biomolecules has not been widely analysed. This study aimed to assess the effects of four factors (species, microclimate, seasonality and hydration state) and their interactions on the biomolecule frequency detected by Raman Spectroscopy. We included cyanobacterial biocrusts, and the lichens Diploschistes diacapsis, Squamarina lentigera, and Lepraria isidiata; two contrasted microclimates (typical and marginal), two contrasted seasons (hot and dry vs cool and wet) and two hydration states (dry and wet). "Species" was the most influential factor in the identity and frequency of the main biomolecules. Microclimatic differences in the range of the local specific habitats only influenced the biomolecules in cyanobacteria. There was a quadruple interaction among the factors, the effects being different mainly depending on the species. At D. diacapsis, the production of their main biomolecules depended on microclimate, although it also depended on seasonality. Nevertheless, in L. isidiata and S. lentigera microclimatic differences did not significantly affect the production of biomolecules. In the lichen species, the microhabitats exposed to relatively larger incident radiation did not show significantly larger relative frequency of photoprotective biomolecules. No clear connection between higher production of oxalates and drier microhabitats was found, suggesting that the synthesis of oxalates is not related to water reserve strategy. The pros and cons of monitor biomolecules in biocrust by Raman spectrometry were also discussed. Copyright © 2016. Published by Elsevier B.V.
[Hygienic assessment of conditions of the exploitation of facilities of the urban drainage system].
Alikbayeva, L A; Iakubova, I Sh; Ryzhkov, A L; Lavrinova, A A; Sidorov, A A
The aim of the study was the hygienic characteristics of the location of sewage pumping stations (SPSs) in the residential area of the city and the assessment of working conditions for the staff. The features of the technological process at the SPSs resulted in the formation of specific working conditions characterized by the presence of a cooling microclimate, noise production, technological vibration, air pollution by microorganisms. The assessment of working conditions has allowed to refer them to the 3 class (harmful working conditions) of the 2 and 3 degree. Preventive measures for SPSs should include the use of equipment for cleaning the air of working zone, having a combined odourremoving and microbicidal action; the automation of the labor process; the installation of additional equipment for filtering air circulating in workplaces and emitting into the atmosphere; provision of sealing equipment with the use of noise insulating materials.
Technology Utilization House Study Report. [For Energy Conservation
NASA Technical Reports Server (NTRS)
1974-01-01
The objectives of Project TECH are: (1) to construct a single family detached dwelling for demonstrating the application of advanced technology and minimizing the requirement for energy and utility services, and (2) to help influence future development in home construction by defining the interaction of integrated energy and water management systems with building configuration and construction materials. Components and methods expected to be cost effective over a 20 year span were studied. Emphasis was placed on the utilization of natural heating and cooling characteristics. Orientation and location of windows, landscaping, natural ventilation, and characteristics of the local climate and microclimate were intended to be used to best advantage. Energy conserving homes are most efficient when design for specific sites, therefore project TECH should not be considered a prototype design suitable for all locations. However, it does provide ideas and analytical methods which can be applied to some degree in all housing.
Tree-hugging koalas demonstrate a novel thermoregulatory mechanism for arboreal mammals
Briscoe, Natalie J.; Handasyde, Kathrine A.; Griffiths, Stephen R.; Porter, Warren P.; Krockenberger, Andrew; Kearney, Michael R.
2014-01-01
How climate impacts organisms depends not only on their physiology, but also whether they can buffer themselves against climate variability via their behaviour. One of the way species can withstand hot temperatures is by seeking out cool microclimates, but only if their habitat provides such refugia. Here, we describe a novel thermoregulatory strategy in an arboreal mammal, the koala Phascolarctos cinereus. During hot weather, koalas enhanced conductive heat loss by seeking out and resting against tree trunks that were substantially cooler than ambient air temperature. Using a biophysical model of heat exchange, we show that this behaviour greatly reduces the amount of heat that must be lost via evaporative cooling, potentially increasing koala survival during extreme heat events. While it has long been known that internal temperatures of trees differ from ambient air temperatures, the relevance of this for arboreal and semi-arboreal mammals has not previously been explored. Our results highlight the important role of tree trunks as aboveground ‘heat sinks’, providing cool local microenvironments not only for koalas, but also for all tree-dwelling species. PMID:24899683
Afanas'eva, R F
2008-01-01
The article deals with basic points concerning influence of microclimate on humans and tasks of its regulation in contemporary conditions. The authors described universality of microclimate from viewpoint of producing functional state and health state of human, so microclimate should be assessed consistently and systematically through all aspects of its influence, with complex approach to evaluation (clothing, physical activity, etc.).
Di, Sun; Guan, De-xin; Yuan, Feng-hui; Wang, An-zhi; Wu, Jia-bing
2010-11-01
By using Granier's thermal dissipation probe, the sap flow velocity of the poplars in agroforestry system in west Liaoning was continuously measured, and the microclimate factors were measured synchronously. Dislocation contrast method was applied to analyze the sap flow velocity and corresponding air temperature, air humidity, net radiation, and vapor pressure deficit to discuss the time lag effect between poplar' s sap flow velocity and microclimate factors on sunny days. It was found that the poplar's sap flow velocity advanced of air temperature, air humidity, and vapor pressure deficit, and lagged behind net radiation. The sap flow velocity in June, July, August, and September was advanced of 70, 30, 50, and 90 min to air temperature, of 80, 30, 40, and 90 min to air humidity, and of 90, 50, 70, and 120 min to vapor pressure deficit, but lagged behind 10, 10, 40, and 40 min to net radiation, respectively. The time lag time of net radiation was shorter than that of air temperature, air humidity, and vapor pressure. The regression analysis showed that in the cases the time lag effect was contained and not, the determination coefficients between comprehensive microclimate factor and poplar's sap flow velocity were 0.903 and 0.855, respectively, indicating that when the time lag effect was contained, the determination coefficient was ascended by 2.04%, and thus, the simulation accuracy of poplar's sap flow velocity was improved.
Lee, Yejin; Hong, Kyunghi; Hong, Sung-Ae
2007-05-01
Garment fit and resultant air volume is a crucial factor in thermal insulation, and yet, it has been difficult to quantify the air volume of clothing microclimate and relate it to the thermal insulation value just using the information on the size of clothing pattern without actual 3D volume measurement in wear condition. As earlier methods for the computation of air volume in clothing microclimate, vacuum over suit and circumference model have been used. However, these methods have inevitable disadvantages in terms of cost or accuracy due to the limitations of measurement equipment. In this paper, the phase-shifting moiré topography was introduced as one of the 3D scanning tools to measure the air volume of clothing microclimate quantitatively. The purpose of this research is to adopt a non-contact image scanning technology, phase-shifting moiré topography, to ascertain relationship between air volume and insulation value of layered clothing systems in wear situations where the 2D fabric creates new conditions in 3D spaces. The insulation of vests over shirts as a layered clothing system was measured with a thermal manikin in the environmental condition of 20 degrees C, 65% RH and air velocity of 0.79 m/s. As the pattern size increased, the insulation of the clothing system was increased. But beyond a certain limit, the insulation started to decrease due to convection and ventilation, which is more apparent when only the vest was worn over the torso of manikin. The relationship between clothing air volume and insulation was difficult to predict with a single vest due to the extreme openings which induced active ventilation. But when the vest was worn over the shirt, the effects of thickness of the fabrics on insulation were less pronounced compared with that of air volume. In conclusion, phase-shifting moiré topography was one of the efficient and accurate ways of quantifying air volume and its distribution across the clothing microclimate. It is also noted that air volume becomes more crucial factor in predicting thermal insulation when clothing is layered.
Assessing the Performance of Large Scale Green Roofs and Their Impact on the Urban Microclimate
NASA Astrophysics Data System (ADS)
Smalls-Mantey, L.; Foti, R.; Montalto, F. A.
2015-12-01
In ultra-urban environments green roofs offer a feasible solution to add green infrastructure (GI) in neighborhoods where space is limited. Green roofs offer the typical advantages of urban GI such as stormwater reduction and management while providing direct benefits to the buildings on which they are installed through thermal protection and mitigation of temperature fluctuations. At 6.8 acres, the Jacob K. Javits Convention Center (JJCC) in New York City, hosts the second largest green roof in the United States. Since its installation in August 2013, the Sustainable Water Resource (SWRE) Laboratory at Drexel University has monitored the climate on and around the green roof by means of four weather stations situated on various roof and ground locations. Using two years of fine scale climatic data collected at the JJCC, this study explores the energy balance of a large scale green roof system. Temperature, radiation, evapotranspiration and wind profiles pre- and post- installation of the JJCC green roof were analyzed and compared across monitored locations, with the goal of identifying the impact of the green roof on the building and urban micro-climate. Our findings indicate that the presence of the green roof, not only altered the climatic conditions above the JJCC, but also had a measurable impact on the climatic profile of the areas immediately surrounding it. Furthermore, as a result of the mitigation of roof temperature fluctuations and of the cooling provided during warmer months, an improvement of the building thermal efficiency was contextually observed. Such findings support the installation of GI as an effective practice in urban settings and important in the discussion of key issues including energy conservation measures, carbon emission reductions and the mitigation of urban heat islands.
NASA Astrophysics Data System (ADS)
Buhmirov, V. V.; Prorokova, M. V.
2015-01-01
The method of determining a microclimate comfort level have been developed, taking into account the main parameters influencing the microclimate in residential, public and administration buildings, their mutual influence on the comfort level, and air quality.
Impact of dangerous microclimate conditions within an enclosed vehicle on pediatric thermoregulation
NASA Astrophysics Data System (ADS)
Grundstein, Andrew; Duzinski, Sarah; Null, Jan
2017-01-01
Pediatric vehicular hyperthermia (PVH) persists as the leading cause of non-crash, vehicle-related deaths among US children with an average of 37 children dying after being left unattended in motor vehicles each year. Our study aims to demonstrate the microclimate conditions within an enclosed vehicle that lead infants and small children to reach key physiological heat thresholds: uncompensable heating (>37 °C) and heatstroke (>40 °C) under "worst case" conditions. A modified version of the Man-Environment Heat Exchange Model was used to compute the length of time for an infant to reach these thresholds. Several different scenarios were modeled using different initial cabin air temperatures. Assuming full sun exposure and maximum heating rates, an infant may reach uncompensable heating within 5 min and experience hyperthermia anywhere from 15 to 55 min depending on the starting cabin air temperature. The rapid approach of these heat-related thresholds occurs as enclosed vehicles maximize heating and minimize cooling mechanisms, leading to net heating and increase in core body temperatures. Health experts can use this information to support public health messaging on the topic of PVH by explaining why it is important to never leave a child alone in a car and increase the public perception of severity and susceptibility to this ongoing public health issue.
Voelker, C; Alsaad, H
2018-05-01
This study aims to develop an approach to couple a computational fluid dynamics (CFD) solver to the University of California, Berkeley (UCB) thermal comfort model to accurately evaluate thermal comfort. The coupling was made using an iterative JavaScript to automatically transfer data for each individual segment of the human body back and forth between the CFD solver and the UCB model until reaching convergence defined by a stopping criterion. The location from which data are transferred to the UCB model was determined using a new approach based on the temperature difference between subsequent points on the temperature profile curve in the vicinity of the body surface. This approach was used because the microclimate surrounding the human body differs in thickness depending on the body segment and the surrounding environment. To accurately simulate the thermal environment, the numerical model was validated beforehand using experimental data collected in a climate chamber equipped with a thermal manikin. Furthermore, an example of the practical implementations of this coupling is reported in this paper through radiant floor cooling simulation cases, in which overall and local thermal sensation and comfort were investigated using the coupled UCB model. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
ERIC Educational Resources Information Center
Fontaine, Joseph J.; Stier, Samuel C.; Maggio, Melissa L.; Decker, Karie L.
2007-01-01
Students can gain an appreciation for the structure and function of local environments by studying the potential impacts of small changes in local microclimate on plant distribution. The concept of microclimate is easy for students to comprehend, simple to measure, exists in all schoolyards, and has important and tangible ecological implications.…
NASA Astrophysics Data System (ADS)
Brown, Robert Douglas
Several components of a system for quantitative application of climatic statistics to landscape planning and design (CLIMACS) have been developed. One component model (MICROSIM) estimated the microclimate at the top of a remote crop using physically-based models and inputs of weather station data. Temperatures at the top of unstressed, uniform crops on flat terrain within 1600 m of a recording weather station were estimated within 1.0 C 96% of the time for a corn crop and 92% of the time for a soybean crop. Crop top winds were estimated within 0.4 m/s 92% of the time for corn and 100% of the time for soybean. This is of sufficient accuracy for application in landscape planning and design models. A physically-based model (COMFA) was developed for the determination of outdoor human thermal comfort from microclimate inputs. Estimated versus measured comfort levels in a wide range of environments agreed with a correlation coefficient of r = 0.91. Using these components, the CLIMACS concept has been applied to a typical planning example. Microclimate data were generated from weather station information using MICROSIM, then input to COMFA and to a house energy consumption model called HOTCAN to derive quantitative climatic justification for design decisions.
[Bronchopulmonary diseases in workers engaged in deep-mined extraction of copper-nickel ore].
Siurin, S A; Derevoedov, A A; Nikanov, A N
2008-01-01
Examinations were made in 220 male workers exposed to dust-gas (low-silicon dioxide, nitric oxides, and carbon oxide) mixture, physical exercises, and cooling microclimate on deep-mined output of copper-nickel ore. Twenty-eight per cent of the workers were found to have evolving chronic bronchitis that did not substantially affect the patients' working capacity; 3.2% had chronic obstructive pulmonary disease and 1.4% had asthma that had developed before the onset of professional activity. 32.3% of the examinees were ascertained to have individual clinicofunctional disorders that permit their identification as a bronchopulmonary disease risk group to carry out early preventive and rehabilitative measures.
Fabrication and Testing of Tapered Electro-spray Nozzles
2012-09-01
4.2 Microclimate Issues .......................................................................................................20 5. Summary and...requirement, while using very low flow rates per nozzle to obtain small combustor geometries. 4.2 Microclimate One of the challenges with this...off the Taylor-cone. To determine if there is an influence of microclimate , the evaporation rate was calculated from the Langmuir equation 1, using
High-Resolution Urban Greenery Mapping for Micro-Climate Modelling Based on 3d City Models
NASA Astrophysics Data System (ADS)
Hofierka, J.; Gallay, M.; Kaňuk, J.; Šupinský, J.; Šašak, J.
2017-10-01
Urban greenery has various positive micro-climate effects including mitigation of heat islands. The primary root of heat islands in cities is in absorption of solar radiation by the mass of building structures, roads and other solid materials. The absorbed heat is subsequently re-radiated into the surroundings and increases ambient temperatures. The vegetation can stop and absorb most of incoming solar radiation mostly via the photosynthesis and evapotranspiration process. However, vegetation in mild climate of Europe manifests considerable annual seasonality which can also contribute to the seasonal change in the cooling effect of the vegetation on the urban climate. Modern methods of high-resolution mapping and new generations of sensors have brought opportunity to record the dynamics of urban greenery in a high resolution in spatial, spectral, and temporal domains. In this paper, we use the case study of the city of Košice in Eastern Slovakia to demonstrate the methodology of 3D mapping and modelling the urban greenery during one vegetation season in 2016. The purpose of this monitoring is to capture 3D effects of urban greenery on spatial distribution of solar radiation in urban environment. Terrestrial laser scanning was conducted on four selected sites within Košice in ultra-high spatial resolution. The entire study area, which included these four smaller sites, comprised 4 km2 of the central part of the city was flown within a single airborne lidar and photogrammetric mission to capture the upper parts of buildings and vegetation. The acquired airborne data were used to generate a 3D city model and the time series of terrestrial lidar data were integrated with the 3D city model. The results show that the terrestrial and airborne laser scanning techniques can be effectively used to monitor seasonal changes in foliage of trees in order to assess the transmissivity of the canopy for microclimate modelling.
Cornthwaite, H M; Watterson, J H
2014-10-01
The influence of body position and microclimate on ketamine (KET) and metabolite distribution in decomposed bone tissue was examined. Rats received 75 mg/kg (i.p.) KET (n = 30) or remained drug-free (controls, n = 4). Following euthanasia, rats were divided into two groups and placed outdoors to decompose in one of the three positions: supine (SUP), prone (PRO) or upright (UPR). One group decomposed in a shaded, wooded microclimate (Site 1) while the other decomposed in an exposed sunlit microclimate with gravel substrate (Site 2), roughly 500 m from Site 1. Following decomposition, bones (lumbar vertebrae, thoracic vertebra, cervical vertebrae, rib, pelvis, femora, tibiae, humeri and scapulae) were collected and sorted for analysis. Clean, ground bones underwent microwave-assisted extraction using acetone : hexane mixture (1 : 1, v/v), followed by solid-phase extraction and analysis using GC-MS. Drug levels, expressed as mass normalized response ratios, were compared across all bone types between body position and microclimates. Bone type was a main effect (P < 0.05) for drug level and drug/metabolite level ratio for all body positions and microclimates examined. Microclimate and body position significantly influenced observed drug levels: higher levels were observed in carcasses decomposing in direct sunlight, where reduced entomological activity led to slowed decomposition. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Solar Maps Development: How the Maps Were Made | Geospatial Data Science |
10% of a true measured value within the grid cell. Due to terrain effects and other microclimate effects and other microclimate influences, the local cloud cover can vary significantly even within a approximately 10% of a true measured value within the grid cell. Due to terrain effects and other microclimate
The influence of surface type on the absorbed radiation by a human under hot, dry conditions
NASA Astrophysics Data System (ADS)
Hardin, A. W.; Vanos, J. K.
2018-01-01
Given the predominant use of heat-retaining materials in urban areas, numerous studies have addressed the urban heat island mitigation potential of various "cool" options, such as vegetation and high-albedo surfaces. The influence of altered radiational properties of such surfaces affects not only the air temperature within a microclimate, but more importantly the interactions of long- and short-wave radiation fluxes with the human body. Minimal studies have assessed how cool surfaces affect thermal comfort via changes in absorbed radiation by a human ( R abs) using real-world, rather than modeled, urban field data. The purpose of the current study is to assess the changes in the absorbed radiation by a human—a critical component of human energy budget models—based on surface type on hot summer days (air temperatures > 38.5∘C). Field tests were conducted using a high-end microclimate station under predominantly clear sky conditions over ten surfaces with higher sky view factors in Lubbock, Texas. Three methods were used to measure and estimate R abs: a cylindrical radiation thermometer (CRT), a net radiometer, and a theoretical estimation model. Results over dry surfaces suggest that the use of high-albedo surfaces to reduce overall urban heat gain may not improve acute human thermal comfort in clear conditions due to increased reflected radiation. Further, the use of low-cost instrumentation, such as the CRT, shows potential in quantifying radiative heat loads within urban areas at temporal scales of 5-10 min or greater, yet further research is needed. Fine-scale radiative information in urban areas can aid in the decision-making process for urban heat mitigation using non-vegetated urban surfaces, with surface type choice is dependent on the need for short-term thermal comfort, or reducing cumulative heat gain to the urban fabric.
NASA Astrophysics Data System (ADS)
Li, Xia; Mitra, Chandana; Dong, Li; Yang, Qichun
2018-02-01
To explore potential climatic consequences of land cover change in the Kolkata Metropolitan Development area, we projected microclimate conditions in this area using the Weather Research and Forecasting (WRF) model driven by future land use scenarios. Specifically, we considered two land conversion scenarios including an urbanization scenario that all the wetlands and croplands would be converted to built-up areas, and an irrigation expansion scenario in which all wetlands and dry croplands would be replaced by irrigated croplands. Results indicated that land use and land cover (LULC) change would dramatically increase regional temperature in this area under the urbanization scenario, but expanded irrigation tended to have a cooling effect. In the urbanization scenario, precipitation center tended to move eastward and lead to increased rainfall in eastern parts of this region. Increased irrigation stimulated rainfall in central and eastern areas but reduced rainfall in southwestern and northwestern parts of the study area. This study also demonstrated that urbanization significantly reduced latent heat fluxes and albedo of land surface; while increased sensible heat flux changes following urbanization suggested that developed land surfaces mainly acted as heat sources. In this study, climate change projection not only predicts future spatiotemporal patterns of multiple climate factors, but also provides valuable insights into policy making related to land use management, water resource management, and agriculture management to adapt and mitigate future climate changes in this populous region.
Geostatistical modeling of riparian forest microclimate and its implications for sampling
Eskelson, B.N.I.; Anderson, P.D.; Hagar, J.C.; Temesgen, H.
2011-01-01
Predictive models of microclimate under various site conditions in forested headwater stream - riparian areas are poorly developed, and sampling designs for characterizing underlying riparian microclimate gradients are sparse. We used riparian microclimate data collected at eight headwater streams in the Oregon Coast Range to compare ordinary kriging (OK), universal kriging (UK), and kriging with external drift (KED) for point prediction of mean maximum air temperature (Tair). Several topographic and forest structure characteristics were considered as site-specific parameters. Height above stream and distance to stream were the most important covariates in the KED models, which outperformed OK and UK in terms of root mean square error. Sample patterns were optimized based on the kriging variance and the weighted means of shortest distance criterion using the simulated annealing algorithm. The optimized sample patterns outperformed systematic sample patterns in terms of mean kriging variance mainly for small sample sizes. These findings suggest methods for increasing efficiency of microclimate monitoring in riparian areas.
Measuring the human body's microclimate using a thermal manikin.
Voelker, C; Maempel, S; Kornadt, O
2014-12-01
The human body is surrounded by a microclimate, which results from its convective release of heat. In this study, the air temperature and flow velocity of this microclimate were measured in a climate chamber at various room temperatures, using a thermal manikin simulating the heat release of the human being. Different techniques (Particle Streak Tracking, thermography, anemometry, and thermistors) were used for measurement and visualization. The manikin surface temperature was adjusted to the particular indoor climate based on simulations with a thermoregulation model (UCBerkeley Thermal Comfort Model). We found that generally, the microclimate is thinner at the lower part of the torso, but expands going up. At the head, there is a relatively thick thermal layer, which results in an ascending plume above the head. However, the microclimate shape strongly depends not only on the body segment, but also on boundary conditions: The higher the temperature difference between the surface temperature of the manikin and the air temperature, the faster the airflow in the microclimate. Finally, convective heat transfer coefficients strongly increase with falling room temperature, while radiative heat transfer coefficients decrease. The type of body segment strongly influences the convective heat transfer coefficient, while only minimally influencing the radiative heat transfer coefficient. The findings of this study generate a better understanding of the human body’s microclimate, which is important in fields such as thermal comfort, HVAC, or indoor air quality. Additionally, the measurements can be used by CFD users for the validation of their simulations. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Predicting the size and elevation of future mountain forests: Scaling macroclimate to microclimate
NASA Astrophysics Data System (ADS)
Cory, S. T.; Smith, W. K.
2017-12-01
Global climate change is predicted to alter continental scale macroclimate and regional mesoclimate. Yet, it is at the microclimate scale that organisms interact with their physiochemical environments. Thus, to predict future changes in the biota such as biodiversity and distribution patterns, a quantitative coupling between macro-, meso-, and microclimatic parameters must be developed. We are evaluating the impact of climate change on the size and elevational distribution of conifer mountain forests by determining the microclimate necessary for new seedling survival at the elevational boundaries of the forest. This initial life stage, only a few centimeters away from the soil surface, appears to be the bottleneck to treeline migration and the expansion or contraction of a conifer mountain forest. For example, survival at the alpine treeline is extremely rare and appears to be limited to facilitated microsites with low sky exposure. Yet, abundant mesoclimate data from standard weather stations have rarely been scaled to the microclimate level. Our research is focusing on an empirical downscaling approach linking microclimate measurements at favorable seedling microsites to the meso- and macro-climate levels. Specifically, mesoclimate values of air temperature, relative humidity, incident sunlight, and wind speed from NOAA NCEI weather stations can be extrapolated to the microsite level that is physiologically relevant for seedling survival. Data will be presented showing a strong correlation between incident sunlight measured at 2-m and seedling microclimate, despite large differences from seedling/microsite temperatures. Our downscaling approach will ultimately enable predictions of microclimate from the much more abundant mesoclimate data available from a variety of sources. Thus, scaling from macro- to meso- to microclimate will be possible, enabling predictions of climate change models to be translated to the microsite level. This linkage between measurement scales will enable a more precise prediction of the effects of climate change on the future extent and elevational distribution of our mountain forests and an accompanying array of critical ecosystem services.
Grisham, Blake A.; Godar, Alixandra J.; Boal, Clint W.; Haukos, David A.
2016-01-01
The range of Lesser Prairie-Chickens (Tympanuchus pallidicinctus) spans 4 unique ecoregions along 2 distinct environmental gradients. The Sand Shinnery Oak Prairie ecoregion of the Southern High Plains of New Mexico and Texas is environmentally isolated, warmer, and more arid than the Short-Grass, Sand Sagebrush, and Mixed-Grass Prairie ecoregions in Colorado, Kansas, Oklahoma, and the northeast panhandle of Texas. Weather is known to influence Lesser Prairie-Chicken nest survival in the Sand Shinnery Oak Prairie ecoregion; regional variation may also influence nest microclimate and, ultimately, survival during incubation. To address this question, we placed data loggers adjacent to nests during incubation to quantify temperature and humidity distribution functions in 3 ecoregions. We developed a suite of a priori nest survival models that incorporated derived microclimate parameters and visual obstruction as covariates in Program MARK. We monitored 49 nests in Mixed-Grass, 22 nests in Sand Shinnery Oak, and 30 nests in Short-Grass ecoregions from 2010 to 2014. Our findings indicated that (1) the Sand Shinnery Oak Prairie ecoregion was hotter and drier during incubation than the Mixed- and Short-Grass ecoregions; (2) nest microclimate varied among years within ecoregions; (3) visual obstruction was positively associated with nest survival; but (4) daily nest survival probability decreased by 10% every half-hour when temperature was greater than 34°C and vapor pressure deficit was less than −23 mmHg during the day (about 0600–2100 hours). Our major finding confirmed microclimate thresholds for nest survival under natural conditions across the species' distribution, although Lesser Prairie-Chickens are more likely to experience microclimate conditions that result in nest failures in the Sand Shinnery Oak Prairie ecoregion. The species would benefit from identification of thermal landscapes and management actions that promote cooler, more humid nest microclimates.
Mayor, T S; Couto, S; Psikuta, A; Rossi, R M
2015-12-01
The ability of clothing to provide protection against external environments is critical for wearer's safety and thermal comfort. It is a function of several factors, such as external environmental conditions, clothing properties and activity level. These factors determine the characteristics of the different microclimates existing inside the clothing which, ultimately, have a key role in the transport processes occurring across clothing. As an effort to understand the effect of transport phenomena in clothing microclimates on the overall heat transport across clothing structures, a numerical approach was used to study the buoyancy-driven heat transfer across horizontal air layers trapped inside air impermeable clothing. The study included both the internal flow occurring inside the microclimate and the external flow occurring outside the clothing layer, in order to analyze the interdependency of these flows in the way heat is transported to/from the body. Two-dimensional simulations were conducted considering different values of microclimate thickness (8, 25 and 52 mm), external air temperature (10, 20 and 30 °C), external air velocity (0.5, 1 and 3 m s(-1)) and emissivity of the clothing inner surface (0.05 and 0.95), which implied Rayleigh numbers in the microclimate spanning 4 orders of magnitude (9 × 10(2)-3 × 10(5)). The convective heat transfer coefficients obtained along the clothing were found to strongly depend on the transport phenomena in the microclimate, in particular when natural convection is the most important transport mechanism. In such scenario, convective coefficients were found to vary in wavy-like manner, depending on the position of the flow vortices in the microclimate. These observations clearly differ from data in the literature for the case of air flow over flat-heated surfaces with constant temperature (which shows monotonic variations of the convective heat transfer coefficients, along the length of the surface). The flow patterns and temperature fields in the microclimates were found to strongly depend on the characteristics of the external boundary layer forming along the clothing and on the distribution of temperature in the clothing. The local heat transfer rates obtained in the microclimate are in marked contrast with those found in the literature for enclosures with constant-temperature active walls. These results stress the importance of coupling the calculation of the internal and the external flows and of the heat transfer convective and radiative components, when analyzing the way heat is transported to/from the body.
Rajkovich, Nicholas B; Larsen, Larissa
2016-01-25
Collecting a fine scale of microclimate data can help to determine how physical characteristics (e.g., solar radiation, albedo, sky view factor, vegetation) contribute to human exposure to ground and air temperatures. These data also suggest how urban design strategies can reduce the negative impacts of the urban heat island effect. However, urban microclimate measurement poses substantial challenges. For example, data taken at local airports are not representative of the conditions at the neighborhood or district level because of variation in impervious surfaces, vegetation, and waste heat from vehicles and buildings. In addition, fixed weather stations cannot be deployed quickly to capture data from a heat wave. While remote sensing can provide data on land cover and ground surface temperatures, resolution and cost remain significant limitations. This paper describes the design and validation of a mobile measurement bicycle. This bicycle permits movement from space to space within a city to assess the physical and thermal properties of microclimates. The construction of the vehicle builds on investigations of the indoor thermal environment of buildings using thermal comfort carts.
Rajkovich, Nicholas B.; Larsen, Larissa
2016-01-01
Collecting a fine scale of microclimate data can help to determine how physical characteristics (e.g., solar radiation, albedo, sky view factor, vegetation) contribute to human exposure to ground and air temperatures. These data also suggest how urban design strategies can reduce the negative impacts of the urban heat island effect. However, urban microclimate measurement poses substantial challenges. For example, data taken at local airports are not representative of the conditions at the neighborhood or district level because of variation in impervious surfaces, vegetation, and waste heat from vehicles and buildings. In addition, fixed weather stations cannot be deployed quickly to capture data from a heat wave. While remote sensing can provide data on land cover and ground surface temperatures, resolution and cost remain significant limitations. This paper describes the design and validation of a mobile measurement bicycle. This bicycle permits movement from space to space within a city to assess the physical and thermal properties of microclimates. The construction of the vehicle builds on investigations of the indoor thermal environment of buildings using thermal comfort carts. PMID:26821037
Seasonal Trends in Airborne Fungal Spores in Coastal California Ecosystems
NASA Astrophysics Data System (ADS)
Morfin, J.; Crandall, S. G.; Gilbert, G. S.
2014-12-01
Airborne fungal spores cause disease in plants and animals and may trigger respiratory illnesses in humans. In terrestrial systems, fungal sporulation, germination, and persistence are strongly regulated by local meteorological conditions. However, few studies investigate how microclimate affects the spatio-temporal dynamics of airborne spores. We measured fungal aerospora abundance and microclimate at varying spatial and time scales in coastal California in three habitat-types: coast redwood forest, mixed-evergreen forest, and maritime chaparral. We asked: 1) is there a difference in total airborne spore concentration between habitats, 2) when do we see peak spore counts, and 3) do spore densities correlate with microclimate conditions? Fungal spores were caught from the air with a volumetric vacuum air spore trap during the wet season (January - March) in 2013 and 2014, as well as monthly in 2014. Initial results suggest that mixed-evergreen forests exhibit the highest amounts of spore abundance in both years compared to the other habitats. This may be due to either a higher diversity of host plants in mixed-evergreen forests or a rich leaf litter layer that may harbor a greater abundance of saprotrophic fungi. Based on pilot data, we predict that temperature and to a lesser degree, relative humidity, will be important microclimate predictors for high spore densities. These data are important for understanding when and under what weather conditions we can expect to see high levels of fungal spores in the air; this can be useful information for managers who are interested in treating diseased plants with fungicides.
Utilising green and bluespace to mitigate urban heat island intensity.
Gunawardena, K R; Wells, M J; Kershaw, T
2017-04-15
It has long been recognised that cities exhibit their own microclimate and are typically warmer than the surrounding rural areas. This 'mesoscale' influence is known as the urban heat island (UHI) effect and results largely from modification of surface properties leading to greater absorption of solar radiation, reduced convective cooling and lower water evaporation rates. Cities typically contain less vegetation and bodies of water than rural areas, and existing green and bluespace is often under threat from increasing population densities. This paper presents a meta-analysis of the key ways in which green and bluespace affect both urban canopy- and boundary-layer temperatures, examined from the perspectives of city-planning, urban climatology and climate science. The analysis suggests that the evapotranspiration-based cooling influence of both green and bluespace is primarily relevant for urban canopy-layer conditions, and that tree-dominated greenspace offers the greatest heat stress relief when it is most needed. However, the magnitude and transport of cooling experienced depends on size, spread, and geometry of greenspaces, with some solitary large parks found to offer minimal boundary-layer cooling. Contribution to cooling at the scale of the urban boundary-layer climate is attributed mainly to greenspace increasing surface roughness and thereby improving convection efficiency rather than evaporation. Although bluespace cooling and transport during the day can be substantial, nocturnal warming is highlighted as likely when conditions are most oppressive. However, when both features are employed together they can offer many synergistic ecosystem benefits including cooling. The ways in which green and bluespace infrastructure is applied in future urban growth strategies, particularly in countries expected to experience rapid urbanisation, warrants greater consideration in urban planning policy to mitigate the adverse effects of the UHI and enhance climate resilience. Copyright © 2017 The Author(s). Published by Elsevier B.V. All rights reserved.
[Sanitary epidemiologic safety and technical regulations on railway transport].
Leksin, A G
2009-01-01
The author necessitated that requirements on sanitary and epidemiologic safety of life support systems for engine driver cabin (microclimate maintainance system, protection from vibration and noise, illumination, workplace ergonomics, etc) should be included into technical regulations for railway vehicles, both newly constructed and modernized.
NASA Astrophysics Data System (ADS)
Naot, O.; Mahrer, Y.
1991-08-01
A numerical two-dimensional model based on higher-order closure assumptions is developed to simulate the horizontal microclimate distribution over an irrigated field in arid surroundings. The model considers heat, mass, momentum, and radiative fluxes in the soil-plant-atmosphere system. Its vertical domain extends through the whole planetary boundary layer. The model requires temporal solar and atmospheric radiation data, as well as temporal boundary conditions for wind-speed, air temperature, and humidity. These boundary conditions are specified by an auxiliary mesoscale model and are incorporated in the microscale model by a nudging method. Vegetation parameters (canopy height, leaf-angle orientation distribution, leaf-area index, photometric properties, root-density distribution), soil texture, and soil-hydraulic and photometric properties are considered. The model is tested using meteorological data obtained in a drip-irrigated cotton field located in an extremely arid area, where strong fetch effects are expected. Four masts located 50 m before the leading edge of the field and 10, 30, and 100 m inward from the leading edge are used to measure various meteorological parameters and their horizontal and vertical gradients. Calculated values of air and soil temperatures, wind-speed, net radiation and soil, latent, and sensible heat fluxes agreed well with measurements. Large horizontal gradients of air temperature are both observed and measured within the canopy in the first 40 m of the leading edge. Rate of evapotranspiration at both the upwind and the downwind edges of the field are higher by more than 15% of the midfield value. Model calculations show that a stable thermal stratification is maintained above the whole field for 24 h. The aerodynamic and thermal internal boundary layer (IBL) growth is proportional to the square root of the fetch. This is also the observed rate of growth of the thermal IBL over a cool sea surface.
Analysis of the systems of ventilation of residential houses of Ukraine and Estonia
NASA Astrophysics Data System (ADS)
Savchenko, Olena; Zhelykh, Vasyl; Voll, Hendrik
2017-12-01
The most common ventilation system in residential buildings in Ukraine is natural ventilation. In recent years, due to increased tightness of structures, an increase in the content of synthetic finishing materials in them, the quality of microclimate parameters deteriorated. One of the measures to improve the parameters of indoor air in residential buildings is the use of mechanical inflow and exhaust ventilation system. In this article the regulatory documents concerning the design of ventilation systems in Ukraine and Estonia and the requirements for air exchange in residential buildings are considered. It is established that the existing normative documents in Ukraine are analogous to European norms, which allow design the system of ventilation of residential buildings according to European standards. However, the basis for the design of ventilation systems in Ukraine is the national standards, in which mechanical ventilation, unfortunately, is provided only for the design of high-rise buildings. To maintain acceptable microclimate parameters in residential buildings, it is advisable for designers to apply the requirements for designing ventilation systems in accordance with European standards.
Integration of remote sensing based surface information into a three-dimensional microclimate model
NASA Astrophysics Data System (ADS)
Heldens, Wieke; Heiden, Uta; Esch, Thomas; Mueller, Andreas; Dech, Stefan
2017-03-01
Climate change urges cities to consider the urban climate as part of sustainable planning. Urban microclimate models can provide knowledge on the climate at building block level. However, very detailed information on the area of interest is required. Most microclimate studies therefore make use of assumptions and generalizations to describe the model area. Remote sensing data with area wide coverage provides a means to derive many parameters at the detailed spatial and thematic scale required by urban climate models. This study shows how microclimate simulations for a series of real world urban areas can be supported by using remote sensing data. In an automated process, surface materials, albedo, LAI/LAD and object height have been derived and integrated into the urban microclimate model ENVI-met. Multiple microclimate simulations have been carried out both with the dynamic remote sensing based input data as well as with manual and static input data to analyze the impact of the RS-based surface information and the suitability of the applied data and techniques. A valuable support of the integration of the remote sensing based input data for ENVI-met is the use of an automated processing chain. This saves tedious manual editing and allows for fast and area wide generation of simulation areas. The analysis of the different modes shows the importance of high quality height data, detailed surface material information and albedo.
Unger, K A; Watterson, J H
2016-10-01
The effects of decomposition microclimate on the distribution of dextromethorphan (DXM) and dextrorphan (DXT) in skeletonized remains of rats acutely exposed to DXM were examined. Animals (n = 10) received DXM (75 mg/kg, i.p.), were euthanized 30 min post-dose and immediately allowed to decompose at either Site A (shaded forest microenvironment on a grass-covered soil substrate) or Site B (rocky substrate exposed to direct sunlight, 600 m from Site A). Ambient temperature and relative humidity were automatically recorded 3 cm above rats at each site. Skeletal elements (vertebral columns, ribs, pelvic girdles, femora, tibiae, humeri and scapulae) were harvested, and analyzed using microwave assisted extraction, microplate solid phase extraction, and GC/MS. Drug levels, expressed as mass-normalized response ratios, and the ratios of DXT and DXM levels were compared across bones and between microclimate sites. No significant differences in DXT levels or metabolite/parent ratios were observed between sites or across bones. Only femoral DXM levels differed significantly between microclimate sites. For pooled data, microclimate was not observed to significantly affect analyte levels, nor the ratio of levels of DXT and DXM. These data suggest that microclimate conditions do not influence DXM and metabolite distribution in skeletal remains. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Comparison of microclimate in various land-use systems in Sumatra, Indonesia
NASA Astrophysics Data System (ADS)
Shekhar Badu, Chandra; Meijide, Ana; Gunawan, Dodo; Knohl, Alexander
2017-04-01
Deforestation and land-use changes are ongoing problems for rain forests in Indonesia. The conversion of forests to monocultures of rubber and oil palm plantations reduces not only biodiversity and carbon pools but also affects canopy structure, which is an important determinant of microclimate. There is, however, a lack of quantitative information characterizing the effect of land transformation on microclimate with a systematic experimental design. Here, we report observations microclimatic conditions (air temperature, relative humidity, soil moisture and soil temperature) on a daily, weekly and seasonal basis across four land-use systems (rain forest, jungle rubber, rubber plantation, oil palm plantation) in two near-by landscapes. The data set covers a period of approximately three years from April 2013 to March 2016 and includes one of the strongest El Nino-Southern Oscillation (ENSO) of the last decades. Mean air temperature, soil temperature, relative humidity, and vapour pressure deficit differed significantly between the four land-use systems whereas the mean soil moisture differed significantly between two landscapes. Air temperature, vapour pressure deficit and soil temperature were highest in oil palm and rubber plantations whereas lowest in forest and jungle rubber. Canopy openness was the most dominant control of microclimatic differences across the land-use systems. During the ENSO 2015, a significant increase in mean air temperature, soil temperature and vapour pressure deficit but a decrease in relative air humidity and soil moisture in all four land-use systems was found. The relative effect of ENSO was highest in forest and jungle rubber compared to rubber and oil palm plantations. In conclusion, conversion of forest to rubber and oil palm plantations has led to substantially warmer and drier microclimatic conditions than before.
Li, Xia; Mitra, Chandana; Dong, Li; ...
2017-02-02
In order to explore potential climatic consequences of land cover change in the Kolkata Metropolitan Development area, we projected microclimate conditions in this area using the Weather Research and Forecasting (WRF) model driven by future land use scenarios. Specifically, we considered two land conversion scenarios including an urbanization scenario that all the wetlands and croplands would be converted to built-up areas, and an irrigation expansion scenario in which all wetlands and dry croplands would be replaced by irrigated croplands. Our results indicated that land use and land cover (LULC) change would dramatically increase regional temperature in this area under themore » urbanization scenario, but expanded irrigation tended to have a cooling effect. In the urbanization scenario, precipitation center tended to move eastward and lead to increased rainfall in eastern parts of this region. Increased irrigation stimulated rainfall in central and eastern areas but reduced rainfall in southwestern and northwestern parts of the study area. Our study also demonstrated that urbanization significantly reduced latent heat fluxes and albedo of land surface; while increased sensible heat flux changes following urbanization suggested that developed land surfaces mainly acted as heat sources. In this study, climate change projection not only predicts future spatiotemporal patterns of multiple climate factors, but also provides valuable insights into policy making related to land use management, water resource management, and agriculture management to adapt and mitigate future climate changes in this populous region.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Xia; Mitra, Chandana; Dong, Li
In order to explore potential climatic consequences of land cover change in the Kolkata Metropolitan Development area, we projected microclimate conditions in this area using the Weather Research and Forecasting (WRF) model driven by future land use scenarios. Specifically, we considered two land conversion scenarios including an urbanization scenario that all the wetlands and croplands would be converted to built-up areas, and an irrigation expansion scenario in which all wetlands and dry croplands would be replaced by irrigated croplands. Our results indicated that land use and land cover (LULC) change would dramatically increase regional temperature in this area under themore » urbanization scenario, but expanded irrigation tended to have a cooling effect. In the urbanization scenario, precipitation center tended to move eastward and lead to increased rainfall in eastern parts of this region. Increased irrigation stimulated rainfall in central and eastern areas but reduced rainfall in southwestern and northwestern parts of the study area. Our study also demonstrated that urbanization significantly reduced latent heat fluxes and albedo of land surface; while increased sensible heat flux changes following urbanization suggested that developed land surfaces mainly acted as heat sources. In this study, climate change projection not only predicts future spatiotemporal patterns of multiple climate factors, but also provides valuable insights into policy making related to land use management, water resource management, and agriculture management to adapt and mitigate future climate changes in this populous region.« less
Effects of summer microclimates on behavior of lions and tigers in zoos.
Young, Tory; Finegan, Esther; Brown, Robert D
2013-05-01
The surrounding thermal environment has a direct influence on the well-being of an animal. However, few studies have investigated the microclimatic conditions that result from outdoor zoo enclosure designs and whether this affects where animals choose to spend time. Two African lions (Panthera leo) and two Siberian/Amur tigers (Panthera tigris altaica) were observed for a total of 18 full days during the summer and fall of 2009. Their activities and locations were recorded to the nearest minute of each test day. Simultaneous on-site microclimate measurements were taken of air temperature, relative humidity, solar radiation, and wind. Observations indicated that the locations where the animals chose to spend time were influenced by the microclimatic conditions. All subjects spent more time in the shade on their sunny warm days than on other days and differed from one another in their choice of shade source on all days. Temperature-comparable sunny and cloudy days showed a greater use of sun on the cloudy days. Species-specific differences between the lions (whose native habitat is hot) and the tigers (whose native habitat is temperate with cold winters) were observed with the tigers displaying more cooling behaviors than the lions in terms of solar radiation input and evaporative heat loss. The tigers were also more active than the lions. The results of this study provide new insight into how lions and tigers respond to microclimatic conditions in a captive environment.
Effects of summer microclimates on behavior of lions and tigers in zoos
NASA Astrophysics Data System (ADS)
Young, Tory; Finegan, Esther; Brown, Robert D.
2013-05-01
The surrounding thermal environment has a direct influence on the well-being of an animal. However, few studies have investigated the microclimatic conditions that result from outdoor zoo enclosure designs and whether this affects where animals choose to spend time. Two African lions ( Panthera leo) and two Siberian/Amur tigers ( Panthera tigris altaica) were observed for a total of 18 full days during the summer and fall of 2009. Their activities and locations were recorded to the nearest minute of each test day. Simultaneous on-site microclimate measurements were taken of air temperature, relative humidity, solar radiation, and wind. Observations indicated that the locations where the animals chose to spend time were influenced by the microclimatic conditions. All subjects spent more time in the shade on their sunny warm days than on other days and differed from one another in their choice of shade source on all days. Temperature-comparable sunny and cloudy days showed a greater use of sun on the cloudy days. Species-specific differences between the lions (whose native habitat is hot) and the tigers (whose native habitat is temperate with cold winters) were observed with the tigers displaying more cooling behaviors than the lions in terms of solar radiation input and evaporative heat loss. The tigers were also more active than the lions. The results of this study provide new insight into how lions and tigers respond to microclimatic conditions in a captive environment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Xia; Mitra, Chandana; Dong, Li
To explore potential climatic consequences of land cover change in the Kolkata Metropolitan Development area, we projected microclimate conditions in this area using the Weather Research and Forecasting (WRF) model driven by future land use scenarios. Specifically, we considered two land conversion scenarios including an urbanization scenario that all the wetlands and croplands would be converted to built-up areas, and an irrigation expansion scenario in which all wetlands and dry croplands would be replaced by irrigated croplands. Results indicated that land use and land cover (LULC) change would dramatically increase regional temperature in this area under the urbanization scenario, butmore » expanded irrigation tended to have a cooling effect. In the urbanization scenario, precipitation center tended to move eastward and lead to increased rainfall in eastern parts of this region. Increased irrigation stimulated rainfall in central and eastern areas but reduced rainfall in southwestern and northwestern parts of the study area. This study also demonstrated that urbanization significantly reduced latent heat fluxes and albedo of land surface; while increased sensible heat flux changes following urbanization suggested that developed land surfaces mainly acted as heat sources. In this study, climate change projection not only predicts future spatiotemporal patterns of multiple climate factors, but also provides valuable insights into policy making related to land use management, water resource management, and agriculture management to adapt and mitigate future climate changes in this populous region. (C) 2017 Elsevier Ltd. All rights reserved.« less
Contrasting growth responses of dominant peatland plants to warming and vegetation composition.
Walker, Tom N; Ward, Susan E; Ostle, Nicholas J; Bardgett, Richard D
2015-05-01
There is growing recognition that changes in vegetation composition can strongly influence peatland carbon cycling, with potential feedbacks to future climate. Nevertheless, despite accelerated climate and vegetation change in this ecosystem, the growth responses of peatland plant species to combined warming and vegetation change are unknown. Here, we used a field warming and vegetation removal experiment to test the hypothesis that dominant species from the three plant functional types present (dwarf-shrubs: Calluna vulgaris; graminoids: Eriophorum vaginatum; bryophytes: Sphagnum capillifolium) contrast in their growth responses to warming and the presence or absence of other plant functional types. Warming was accomplished using open top chambers, which raised air temperature by approximately 0.35 °C, and we measured air and soil microclimate as potential mechanisms through which both experimental factors could influence growth. We found that only Calluna growth increased with experimental warming (by 20%), whereas the presence of dwarf-shrubs and bryophytes increased growth of Sphagnum (46%) and Eriophorum (20%), respectively. Sphagnum growth was also negatively related to soil temperature, which was lower when dwarf-shrubs were present. Dwarf-shrubs may therefore promote Sphagnum growth by cooling the peat surface. Conversely, the effect of bryophyte presence on Eriophorum growth was not related to any change in microclimate, suggesting other factors play a role. In conclusion, our findings reveal contrasting abiotic and biotic controls over dominant peatland plant growth, suggesting that community composition and carbon cycling could be modified by simultaneous climate and vegetation change.
NASA Astrophysics Data System (ADS)
Wang, Xueqian; Guo, Weidong; Qiu, Bo; Liu, Ye; Sun, Jianning; Ding, Aijun
2017-04-01
Anthropogenic land use has a significant impact on climate change. Located in the typical East Asian monsoon region, the land-atmosphere interaction in the lower reaches of the Yangtze River is even more complicated due to intensive human activities and different types of land use in this region. To better understand these effects on microclimate change, we compare differences in land surface temperature (Ts) for three land types around Nanjing from March to August, 2013, and then quantify the contribution of land surface factors to these differences (ΔTs) by considering the effects of surface albedo, roughness length, and evaporation. The atmospheric background contribution to ΔTs is also considered based on differences in air temperature (ΔTa). It is found that the cropland cooling effect decreases Ts by 1.76° and the urban heat island effect increases Ts by 1.25°. They have opposite impacts but are both significant in this region. Various changes in surface factors affect radiation and energy distribution and eventually modify Ts. It is the evaporative cooling effect that plays the most important role in this region and accounts for 1.40° of the crop cooling and 2.29° of the urban warming. Moreover, the background atmospheric circulation is also an indispensable part in land-atmosphere feedback induced by land use change and reinforces both these effects.
Distribution of a climate-sensitive species at an interior range margin
Ray, Chris; Beever, Erik; Rodhouse, Thomas J.
2016-01-01
Advances in understanding the factors that limit a species’ range, particularly in the context of climate change, have come disproportionately through investigations at range edges or margins. The margins of a species’ range might often correspond with anomalous microclimates that confer habitat suitability where the species would otherwise fail to persist. We addressed this hypothesis using data from an interior, climatic range margin of the American pika (Ochotona princeps), an indicator of relatively cool, mesic climates in rocky habitats of western North America. Pikas in Lava Beds National Monument, northeastern California, USA, occur at elevations much lower than predicted by latitude and longitude. We hypothesized that pika occurrence within Lava Beds would be associated primarily with features such as “ice caves” in which sub-surface ice persists outside the winter months. We used data loggers to monitor sub-surface temperatures at cave entrances and at non-cave sites, confirming that temperatures were cooler and more stable at cave entrances. We surveyed habitat characteristics and evidence of pika occupancy across a random sample of cave and non-cave sites over a 2-yr period. Pika detection probability was high (~0.97), and the combined occupancy of cave and non-cave sites varied across the 2 yr from 27% to 69%. Contrary to our hypothesis, occupancy was not higher at cave sites. Vegetation metrics were the best predictors of site use by pikas, followed by an edge effect and elevation. The importance of vegetation as a predictor of pika distribution at this interior range margin is congruent with recent studies from other portions of the species’ range. However, we caution that vegetation composition depends on microclimate, which might be the proximal driver of pika distribution. The microclimates available in non-cave crevices accessible to small animals have not been characterized adequately for lava landscapes. We advocate innovation in the acquisition and use of microclimatic data for understanding the distributions of many taxa. Appropriately scaled microclimatic data are increasingly available but rarely used in studies of range dynamics.
The effect of cropping systems and irrigation management on development of potato early blight
USDA-ARS?s Scientific Manuscript database
Crop and soil management may modify canopy and belowground microclimate. However, their effects on potential development and control of early blight are not well documented. Crop management systems [Status Quo (SQ), Soil Conserving (SC), Soil Improving (SI), Disease Suppressive (DS), and Continuou...
Effects of urban green infrastructure (UGI) on local outdoor microclimate during the growing season.
Wang, Yafei; Bakker, Frank; de Groot, Rudolf; Wörtche, Heinrich; Leemans, Rik
2015-12-01
This study analyzed how the variations of plant area index (PAI) and weather conditions alter the influence of urban green infrastructure (UGI) on microclimate. To observe how diverse UGIs affect the ambient microclimate through the seasons, microclimatic data were measured during the growing season at five sites in a local urban area in The Netherlands. Site A was located in an open space; sites B, C, and D were covered by different types and configurations of green infrastructure (grove, a single deciduous tree, and street trees, respectively); and site E was adjacent to buildings to study the effects of their façades on microclimate. Hemispherical photography and globe thermometers were used to quantify PAI and thermal comfort at both shaded and unshaded locations. The results showed that groves with high tree density (site B) have the strongest effect on microclimate conditions. Monthly variations in the differences of mean radiant temperature (∆Tmrt) between shaded and unshaded areas followed the same pattern as the PAI. Linear regression showed a significant positive correlation between PAI and ∆Tmrt. The difference of daily average air temperature (∆T a ) between shaded and unshaded areas was also positively correlated to PAI, but with a slope coefficient below the measurement accuracy (±0.5 °C). This study showed that weather conditions can significantly impact the effectiveness of UGI in regulating microclimate. The results of this study can support the development of appropriate UGI measures to enhance thermal comfort in urban areas.
Microclimate and nest-site selection in Micronesian Kingfishers
Kesler, Dylan C.; Haig, Susan M.
2005-01-01
We studied the relationship between microclimate and nest-site selection in the Pohnpei Micronesian Kingfisher (Todiramphus cinnamominus reichenbachii) which excavates nest cavities from the mudlike nest structures of arboreal termites (Nasutitermes sp.) or termitaria. Mean daily high temperatures at termitaria were cooler and daily low temperatures were warmer than at random sites in the forest. Results also indicate that termitaria provided insulation from temperature extremes, and that temperatures inside termitaria were within the thermoneutral zone of Micronesian Kingfishers more often than those outside. No differences were identified in temperatures at sites where nest termitaria and nonnest termitaria occurred or among the insulation properties of used and unused termitaria. These results suggest that although termitaria provide insulation from thermal extremes and a metabolically less stressful microclimate, king-fishers did not select from among available termitaria based on their thermal properties. Our findings are relevant to conservation efforts for the critically endangered Guam Micronesian Kingfisher (T. c. cinnamominus) which is extinct in the wild and exists only as a captive population. Captive breeding facilities should provide aviaries with daily ambient temperatures ranging from 22.06 A?C to 28.05 A?C to reduce microclimate-associated metabolic stress and to replicate microclimates used by wild Micronesian Kingfishers.
[Hygienic aspects of the microclimate in intensive management of rabbits].
Fiser, A
1994-01-01
In a four-row cowshed adapted for rabbit housing, air temperatures and humidity were recorded ambulantly and instrumentally, air flow rate, cooling variable, gas content in the air, microbial contamination of air and dust deposition were determined ambulantly in the years 1991-1992 and in January to April 1993. The values of ambulant measurings show that at the outside temperature -0.5 degrees C to -5.0 degrees C the microclimate quality decreases particularly with respect to the drop of air temperature in the cowshed below 10.0 degrees C, to the increase in cooling variable up to the value 53.17 mW/cm2 and to the increase in NH3 and CO2 content to 50 ppm and/or 0.45 vol.% in absolute maximum values. In these circumstances, the average determined values of both gases are higher than the standard prescription. At outside temperatures above 27.0 degrees C the average relative air humidity in the cowshed made 69.20% for the average temperature of 25.0 degrees C. To avoid the water vapor tension exceeding the limit in the cowshed air above the value 14.1 mm Hg, when sultry atmosphere sets in, the average relative air humidity should be maximally 59.0%. Hence the cowshed was found to be insufficiently ventilated at high outside temperatures above 27.0 degrees C, and it is recommended to increase the ventilator performance and at the same time to reduce water evaporation from catchpit surfaces when urine output of rabbits is excessive as a result of the increased water intake. Temperature and air humidity readings confirmed the need of heating source installation when the outside temperatures drop below 0.0 degrees C. Evaluation of air microbial contamination showed high counts of molds and particularly of micrococci in comparison with the ambience of a cage facility for piglet raising at a repopulation station with strict hygienic regime. Microbial picture of dust deposition was positively influenced by longitudinal aerosol disinfection of the air in the cowshed.
Seidelmann, Katrin N; Scherer-Lorenzen, Michael; Niklaus, Pascal A
2016-01-01
Effects of tree species diversity on decomposition can operate via a multitude of mechanism, including alterations of microclimate by the forest canopy. Studying such effects in natural settings is complicated by the fact that topography also affects microclimate and thus decomposition, so that effects of diversity are more difficult to isolate. Here, we quantified decomposition rates of standard litter in young subtropical forest stands, separating effects of canopy tree species richness and topography, and quantifying their direct and micro-climate-mediated components. Our litterbag study was carried out at two experimental sites of a biodiversity-ecosystem functioning field experiment in south-east China (BEF-China). The field sites display strong topographical heterogeneity and were planted with tree communities ranging from monocultures to mixtures of 24 native subtropical tree species. Litter bags filled with senescent leaves of three native tree species were placed from Nov. 2011 to Oct. 2012 on 134 plots along the tree species diversity gradient. Topographic features were measured for all and microclimate in a subset of plots. Stand species richness, topography and microclimate explained important fractions of the variations in litter decomposition rates, with diversity and topographic effects in part mediated by microclimatic changes. Tree stands were 2-3 years old, but nevertheless tree species diversity explained more variation (54.3%) in decomposition than topography (7.7%). Tree species richness slowed litter decomposition, an effect that slightly depended on litter species identity. A large part of the variance in decomposition was explained by tree species composition, with the presence of three tree species playing a significant role. Microclimate explained 31.4% of the variance in decomposition, and was related to lower soil moisture. Within this microclimate effect, species diversity (without composition) explained 8.9% and topography 34.4% of variance. Topography mainly affected diurnal temperature amplitudes by varying incident solar radiation.
Seidelmann, Katrin N.; Scherer-Lorenzen, Michael; Niklaus, Pascal A.
2016-01-01
Effects of tree species diversity on decomposition can operate via a multitude of mechanism, including alterations of microclimate by the forest canopy. Studying such effects in natural settings is complicated by the fact that topography also affects microclimate and thus decomposition, so that effects of diversity are more difficult to isolate. Here, we quantified decomposition rates of standard litter in young subtropical forest stands, separating effects of canopy tree species richness and topography, and quantifying their direct and micro-climate-mediated components. Our litterbag study was carried out at two experimental sites of a biodiversity-ecosystem functioning field experiment in south-east China (BEF-China). The field sites display strong topographical heterogeneity and were planted with tree communities ranging from monocultures to mixtures of 24 native subtropical tree species. Litter bags filled with senescent leaves of three native tree species were placed from Nov. 2011 to Oct. 2012 on 134 plots along the tree species diversity gradient. Topographic features were measured for all and microclimate in a subset of plots. Stand species richness, topography and microclimate explained important fractions of the variations in litter decomposition rates, with diversity and topographic effects in part mediated by microclimatic changes. Tree stands were 2–3 years old, but nevertheless tree species diversity explained more variation (54.3%) in decomposition than topography (7.7%). Tree species richness slowed litter decomposition, an effect that slightly depended on litter species identity. A large part of the variance in decomposition was explained by tree species composition, with the presence of three tree species playing a significant role. Microclimate explained 31.4% of the variance in decomposition, and was related to lower soil moisture. Within this microclimate effect, species diversity (without composition) explained 8.9% and topography 34.4% of variance. Topography mainly affected diurnal temperature amplitudes by varying incident solar radiation. PMID:27490180
[Work schedule of electric welders in heating microclimate].
Sorokin, G A; Frolova, N M
2010-01-01
The authors present results of specified hygienically justified timing regulations for setting the variants of work and rest modes within electric welders shift, who work in various postures with variable visual strain while welding in heating microclimate.
Range expansion through fragmented landscapes under a variable climate
Bennie, Jonathan; Hodgson, Jenny A; Lawson, Callum R; Holloway, Crispin TR; Roy, David B; Brereton, Tom; Thomas, Chris D; Wilson, Robert J
2013-01-01
Ecological responses to climate change may depend on complex patterns of variability in weather and local microclimate that overlay global increases in mean temperature. Here, we show that high-resolution temporal and spatial variability in temperature drives the dynamics of range expansion for an exemplar species, the butterfly Hesperia comma. Using fine-resolution (5 m) models of vegetation surface microclimate, we estimate the thermal suitability of 906 habitat patches at the species' range margin for 27 years. Population and metapopulation models that incorporate this dynamic microclimate surface improve predictions of observed annual changes to population density and patch occupancy dynamics during the species' range expansion from 1982 to 2009. Our findings reveal how fine-scale, short-term environmental variability drives rates and patterns of range expansion through spatially localised, intermittent episodes of expansion and contraction. Incorporating dynamic microclimates can thus improve models of species range shifts at spatial and temporal scales relevant to conservation interventions. PMID:23701124
Hetem, Robyn S; Strauss, W Maartin; Fick, Linda G; Maloney, Shane K; Meyer, Leith C R; Shobrak, Mohammed; Fuller, Andrea; Mitchell, Duncan
2012-12-01
Predicting whether behaviour could buffer the effects of climate change on long-lived mammals requires a better understanding of the long-term behavioural responses of mammals to environmental stress. Using biologging, we measured locomotor activity and microclimate selection, over eight months, in five Arabian oryx (Oryx leucoryx) living free in a Saudi Arabian desert. The oryx displayed seasonal flexibility in activity patterns, shifting from a continuous 24-h activity pattern with crepuscular peaks in cooler months to a predominantly nocturnal activity pattern during the hottest months, without reducing the total 24-h activity level. The proportion of total 24-h activity that occurred during daylight hours was just 29±8% during the hottest months, versus 53±8% (mean±SD, n=5 oryx) in the other months. The attenuation in diurnal activity levels during the hot months was accompanied by the selection of cooler microclimates, presumably via shade seeking, during the heat of the day. Analysis of miniature black globe (miniglobe) temperature from a remote sensor on the collar of two female animals revealed that oryx selected microclimates cooler than the microclimates in direct sun at higher environmental heat loads across all periods, but with enhanced efficiency during the dry periods. We have quantified activity re-assignment and microclimate selection as responses to hot arid conditions in a free-living artiodactyl. Such flexible behavioural processes may act to buffer the adverse effects of the progressively hotter and drier conditions predicted to occur with climate change. Copyright © 2012 Elsevier GmbH. All rights reserved.
ERIC Educational Resources Information Center
Sanborn, Mark
2011-01-01
Wireless sensor networks (WSNs) represent a class of miniaturized information systems designed to monitor physical environments. These smart monitoring systems form collaborative networks utilizing autonomous sensing, data-collection, and processing to provide real-time analytics of observed environments. As a fundamental research area in…
Peng, G H
1990-05-01
Experiments were made to ascertain the effects of covering windowpane with plastic film in Hulunbeir region on microclimate and sunshine intensity in the living room. It was found that a good regulative effect on the room microclimate resulted by covering the windowpane with plastic film in the cold region. The room temperature rose distinctly. No evident effects were found on ultra-violet radiation and illumination. But the concentration of carbon dioxide increased to some extent. Attention should be paid to ventilation of the room.
Abiotic vs. biotic influences on habitat selection of coexisting species: Climate change impacts?
Martin, T.E.
2001-01-01
Species are commonly segregated along gradients of microclimate and vegetation. I explore the question of whether segregation is the result of microhabitat partitioning (biotic effects) or choice of differing microclimates (abiotic effects). I explored this question for four ground-nesting bird species that are segregated along a microclimate and vegetation gradient in Arizona. Birds shifted position of their nests on the microhabitat and microclimate gradient in response to changing precipitation over nine years. Similarly, annual bird abundance varied with precipitation across 12 yr. Those shifts in abundance and nesting microhabitat with changing precipitation demonstrate the importance of abiotic influences on bird distributions and habitat choice. However, nest-site shifts and microhabitat use also appear to be influenced by interactions among coexisting species. Moreover, shifts in habitat use by all species caused nest predation (i.e., biotic) costs that increased with increasing distance along the microclimate gradient. These results indicate that abiotic and biotic costs can strongly interact to influence microhabitat choice and abundances of coexisting species. Global climate change impacts have been considered largely in terms of simple distributional shifts, but these results indicate that shifts can also increase biotic costs when species move into habitat types for which they are poorly adapted or that create new biotic interactions.
The Microclimate of a Tropical Evergreen Forest.
1980-08-01
of Human Bioclimate - A Review. World Meteorological Organization Bulletin, Geneva, 56 pp. REFERENCES (con’t) Lee, R., 1978. Forest Micrometeorology...Geophysics, and Bioclimatology , Ser. B 24, 243-251. Pinker, R. (1980): The Microclimate of a dry tropical forest. (Accepted for publication in
Hydrothermal assessment of temporal variability in seedbed microclimate
USDA-ARS?s Scientific Manuscript database
The microclimatic requirements for successful establishment of rangeland species are much more restrictive than those required for maintenance of mature plant communities. We used a 44-year weather record to parameterize a seedbed-microclimate model for estimation of hourly temperature and moisture...
Wireless Sensor Platform for Cultural Heritage Monitoring and Modeling System
Bermudez, Sergio A.; Schrott, Alejandro G.; Tsukada, Masahiko; Kargere, Lucretia; Marianno, Fernando; Hamann, Hendrik F.; López, Vanessa; Leona, Marco
2017-01-01
Results from three years of continuous monitoring of environmental conditions using a wireless sensor platform installed at The Cloisters, the medieval branch of the New York Metropolitan Museum of Art, are presented. The platform comprises more than 200 sensors that were distributed in five galleries to assess temperature and air flow and to quantify microclimate changes using physics-based and statistical models. The wireless sensor network data shows a very stable environment within the galleries, while the dense monitoring enables localized monitoring of subtle changes in air quality trends and impact of visitors on the microclimate conditions. The high spatial and temporal resolution data serves as a baseline study to understand the impact of visitors and building operations on the long-term preservation of art objects. PMID:28858223
Wireless Sensor Platform for Cultural Heritage Monitoring and Modeling System.
Klein, Levente J; Bermudez, Sergio A; Schrott, Alejandro G; Tsukada, Masahiko; Dionisi-Vici, Paolo; Kargere, Lucretia; Marianno, Fernando; Hamann, Hendrik F; López, Vanessa; Leona, Marco
2017-08-31
Results from three years of continuous monitoring of environmental conditions using a wireless sensor platform installed at The Cloisters, the medieval branch of the New York Metropolitan Museum of Art, are presented. The platform comprises more than 200 sensors that were distributed in five galleries to assess temperature and air flow and to quantify microclimate changes using physics-based and statistical models. The wireless sensor network data shows a very stable environment within the galleries, while the dense monitoring enables localized monitoring of subtle changes in air quality trends and impact of visitors on the microclimate conditions. The high spatial and temporal resolution data serves as a baseline study to understand the impact of visitors and building operations on the long-term preservation of art objects.
Measurement of landing mosquito density on humans
USDA-ARS?s Scientific Manuscript database
In conventional vector surveillance systems, adult mosquito density and the rate of human-mosquito contact is estimated from the mosquito numbers captured in mechanical traps. However, the design of the traps, their placement in the habitat and operating time, microclimate, and other environmental ...
ON THE IMPACT OF THE HUMAN (CHILD) MICROCLIMATE ON PASSIVE AEROSOL MONITOR PERFORMANCE
Research into the wind microclimate and its effect on the accuracy and effectiveness of passive aerosol monitors is expanding as the importance of personal monitoring versus regional monitoring increases. The important phenomena for investigation include thermal and dynamic eff...
Stream-riparian areas represent a nexus of biodiversity, with disproportionate numbers of species tied to and interacting within this key habitat. New research in Pacific Northwest headwater forests, especially the characterization of microclimates and amphibian distributions, is...
Simulation of within-canopy radiation exchange
USDA-ARS?s Scientific Manuscript database
Radiation exchange at the surface plays a critical role in the surface energy balance, plant microclimate, and plant growth. The ability to simulate the surface energy balance and the microclimate within the plant canopy is contingent upon simulation of the surface radiation exchange. A validation a...
D.H. Olson; P.D. Anderson; C.A. Frissell; H.H. Welsh; D.F. Bradford
2007-01-01
New science insights are redefining stream riparian zones, particularly relative to headwaters, microclimate conditions, and fauna such as amphibians. We synthesize data on these topics, and propose management approaches to target sensitive biota at reach to landscape scales.
Software Tools for Weed Seed Germination Modeling
USDA-ARS?s Scientific Manuscript database
The next generation of weed seed germination models will need to account for variable soil microclimate conditions. In order to predict this microclimate environment we have developed a suite of individual tools (models) that can be used in conjunction with the next generation of weed seed germinati...
Microclimate in Forest Ecosystem and Landscape Ecology
Jiquan Chen; Sari C. Saunders; Thomas R. Crow; Robert J. Naiman; Kimberley D. Brosofske; Glenn D. Mroz; Brain L. Brookshire; Jerry F. Franklin
1999-01-01
Microclimate is the suite of climatic conditions measured in localized areas near the earth's surface (Geiger 1965). These environmental variables, which include temperature, light, windspeed, and moisture, have been critical throughout human history, providing meaningful indicators for habitat selection and other activities. For example, for 2600 years the...
Rakhmanin Yu A; Shibanov, S E; Kozulya, S V
2016-01-01
The purpose of work: comparison of prevalence among residents, which use or fail to use to clean split systems. Collected information about morbidity rate in 235 cases people during 3 years. The usage of split-systems without their regular cleaning leads to the gain in the level of the prevalence of respiratory diseases by 172.7% if compared with persons, who have no air conditioning systems at home. Also, the average number of disability days increases by 218.1%) and average time of the duration of the disease increases by 71.9%. The annual treatment of split-systems and regular cleaning of filters allowed to reduce the number of diseases. In comparison with the group of people, who fail to clean air conditioning systems, the drop of morbidity rate by 56.6%, average number of disability days by 63.3% and average time of diseases by 30.9% was observed. Regular treatment of air conditioning systems cannot completely repay the morbidity rates to the level of the control group. In comparison with the people, who use no air conditioning systems, the owners of split-systems with regular treatment have lung diseases by 18.4% more often. The average number of disability days and the average time of diseases increased by 16.9% and 18.8%. These changes can be explained by the impact of unfavorable (cooling) microclimate. The impact of split-systems on the health of the population requires a comprehensive study and the subsequent development of normative documents regulating their safe use.
Assessment of turkey vehicle container microclimate on transit during summer season conditions
NASA Astrophysics Data System (ADS)
Carvalho, Rafael H.; Honorato, Danielle C. B.; Guarnieri, Paulo D.; Soares, Adriana L.; Pedrão, Mayka R.; Oba, Alexandre; Paião, Fernanda G.; Ida, Elza I.; Shimokomaki, Massami
2018-06-01
This study evaluated the formed microclimate commercial truck transport practices effects on the turkeys' welfare by measuring Dead on Arrival (DOA) index and pale, soft, and exudative (PSE-like) meat occurrence. The experimental design was entirely randomized in a 6 × 2 factorial arrangements (two truck container compartments × six water shower groups) with birds positioned at superior front (SF), inferior front (IF), superior middle (SM), inferior middle (IM), superior rear (SR), and inferior rear (IR) and two bath treatments: with water shower (WiS) and without water shower (WoS) with eight replications for each treatment. The animals were transported for 95 min' journey from the farm to the slaughterhouse under hot-humidity conditions. The results shown herein indicated the formation of a thermal core at the inferior middle and rear truck container regions, because the heat produced by the birds and the influence of developed microclimate consisting of temperature, relative humidity, and air ventilation. The IM and IR container compartments under the WoS treatment presented the highest ( P < 0.01) numbers of PSE-like meat incidence and DOA index values compared with those located at the front under WiS treatment as the consequence of the altered to birds unbearable conditions within the container microclimate in transit. The formed microclimate during the commercial transport practices under hot-humidity conditions affected the bird's welfare consequently turkey meat qualities.
Assessment of turkey vehicle container microclimate on transit during summer season conditions
NASA Astrophysics Data System (ADS)
Carvalho, Rafael H.; Honorato, Danielle C. B.; Guarnieri, Paulo D.; Soares, Adriana L.; Pedrão, Mayka R.; Oba, Alexandre; Paião, Fernanda G.; Ida, Elza I.; Shimokomaki, Massami
2018-01-01
This study evaluated the formed microclimate commercial truck transport practices effects on the turkeys' welfare by measuring Dead on Arrival (DOA) index and pale, soft, and exudative (PSE-like) meat occurrence. The experimental design was entirely randomized in a 6 × 2 factorial arrangements (two truck container compartments × six water shower groups) with birds positioned at superior front (SF), inferior front (IF), superior middle (SM), inferior middle (IM), superior rear (SR), and inferior rear (IR) and two bath treatments: with water shower (WiS) and without water shower (WoS) with eight replications for each treatment. The animals were transported for 95 min' journey from the farm to the slaughterhouse under hot-humidity conditions. The results shown herein indicated the formation of a thermal core at the inferior middle and rear truck container regions, because the heat produced by the birds and the influence of developed microclimate consisting of temperature, relative humidity, and air ventilation. The IM and IR container compartments under the WoS treatment presented the highest (P < 0.01) numbers of PSE-like meat incidence and DOA index values compared with those located at the front under WiS treatment as the consequence of the altered to birds unbearable conditions within the container microclimate in transit. The formed microclimate during the commercial transport practices under hot-humidity conditions affected the bird's welfare consequently turkey meat qualities.
Assessment of turkey vehicle container microclimate on transit during summer season conditions.
Carvalho, Rafael H; Honorato, Danielle C B; Guarnieri, Paulo D; Soares, Adriana L; Pedrão, Mayka R; Oba, Alexandre; Paião, Fernanda G; Ida, Elza I; Shimokomaki, Massami
2018-06-01
This study evaluated the formed microclimate commercial truck transport practices effects on the turkeys' welfare by measuring Dead on Arrival (DOA) index and pale, soft, and exudative (PSE-like) meat occurrence. The experimental design was entirely randomized in a 6 × 2 factorial arrangements (two truck container compartments × six water shower groups) with birds positioned at superior front (SF), inferior front (IF), superior middle (SM), inferior middle (IM), superior rear (SR), and inferior rear (IR) and two bath treatments: with water shower (WiS) and without water shower (WoS) with eight replications for each treatment. The animals were transported for 95 min' journey from the farm to the slaughterhouse under hot-humidity conditions. The results shown herein indicated the formation of a thermal core at the inferior middle and rear truck container regions, because the heat produced by the birds and the influence of developed microclimate consisting of temperature, relative humidity, and air ventilation. The IM and IR container compartments under the WoS treatment presented the highest (P < 0.01) numbers of PSE-like meat incidence and DOA index values compared with those located at the front under WiS treatment as the consequence of the altered to birds unbearable conditions within the container microclimate in transit. The formed microclimate during the commercial transport practices under hot-humidity conditions affected the bird's welfare consequently turkey meat qualities.
MTCLIM: a mountain microclimate simulation model
Roger D. Hungerford; Ramakrishna R. Nemani; Steven W. Running; Joseph C. Coughlan
1989-01-01
A model for calculating daily microclimate conditions in mountainous terrain is presented. Daily air temperature, shortwave radiation, relative humidity, and precipitation are extrapolated form data measured at National Weather Service stations. The model equations are given and the paper describes how to execute the model. Model outputs are compared with observed data...
Soil N and C Geography of the Salmon River Watershed and the Oregon Coast
NASA Astrophysics Data System (ADS)
Kern, J. S.; Compton, J. E.; Johnson, M. G.
2003-12-01
Diverse soil and geology influence the rich terrestrial and aquatic biota of the Oregon Coast. We characterized the spatial patterns of soil organic C (SOC) and N by assembling county and forest soil surveys combined with new fieldwork, and analyses from sampled soils. The headlands have maximum SOC and N where wind deposited volcanic soil is coupled with a cool, moist climate. The SOC and N decreases inland in similar soils that have a less marine climate influence. The underlying geology (basalt or sedimentary rock) had no affect in SOC and N. The remainder of the watershed has less SOC and N depending on rock content and soil depth which were affected by lithology as well as microclimate, and tree stand history. Extrapolating SOC and N trends to the region provides information for an area with no significant N deposition from air pollution.
Real-Time Thermal Mapping for Heat & Cool Archipelagos of Bengaluru, India
NASA Astrophysics Data System (ADS)
Gopinath, Rajesh; Banerjee, Aditya; Sachin, S.; Tiwari, Prakhar; Wilson, Sunny
2017-12-01
Blessed with a salubrious climate, the city of Bengaluru over the past few decades has constantly witnessed thermal discomfort owing to several Urban Heat islands that have mushroomed within the city. The subsequent increase in builtup area, consequent loss of productive agricultural lands/green zones, encroachment of surface water bodies coupled with the ill-preparedness of decision makers to handle the demand for land have invariably crumbled the natural micro-climate of the city. In this present research, an attempt has been made to detect the distribution of Urban Heat Islands in Bengaluru City by conducting real-time survey at 100 observatories marked across the entire urban & rural locations; with thermohygrometers as per the W.M.O. guidelines. The study confirmed the violation of the Human Thermal Comfort Range in 9, 83, 98, 99, 98 and 80 observatories for the monitoring at 6 AM, 9 AM, 12 PM, 3 PM, 6 PM and 9 PM respectively.
Sampling and modeling riparian forest structure and riparian microclimate
Bianca N.I. Eskelson; Paul D. Anderson; Hailemariam Temesgen
2013-01-01
Riparian areas are extremely variable and dynamic, and represent some of the most complex terrestrial ecosystems in the world. The high variability within and among riparian areas poses challenges in developing efficient sampling and modeling approaches that accurately quantify riparian forest structure and riparian microclimate. Data from eight stream reaches that are...
Hydrothermal assessment of temporal variability in seedbed microclimate
Stuart P. Hardegree; Corey A. Moffet; Gerald N. Flerchinger; Jaepil Cho; Bruce A. Roundy; Thomas A. Jones; Jeremy J. James; Patrick E. Clark; Frederick B. Pierson
2013-01-01
The microclimatic requirements for successful seedling establishment are much more restrictive than those required for adult plant survival. The purpose of the current study was to use hydrothermal germination models and a soil energy and water flux model to evaluate intra- and interannual variability in seedbed microclimate relative to potential germination response...
Structure of the microclimate at a woodland/parking-lot interface
David R. Miller
1977-01-01
Radiation balances and vertical and horizontal profiles of air temperature, vapor pressure and wind speed were measured across the interface of a large asphalt parking lot and an 18-m-tall Quercus velutina forest. The partitioning of available energy over the adjacent areas shows steep gradients between the parking lot and forest microclimates....
Spatial models reveal the microclimatic buffering capacity of old-growth forests
Sarah J. K. Frey; Adam S. Hadley; Sherri L. Johnson; Mark Schulze; Julia A. Jones; Matthew. G. Betts
2016-01-01
Climate change is predicted to cause widespread declines in biodiversity, but these predictions are derived from coarse-resolution climate models applied at global scales. Such models lack the capacity to incorporate microclimate variability, which is critical to biodiversity microrefugia. In forested montane regions, microclimate is thought to be influenced by...
NASA Astrophysics Data System (ADS)
Shamshiri, Redmond Ramin; Jones, James W.; Thorp, Kelly R.; Ahmad, Desa; Man, Hasfalina Che; Taheri, Sima
2018-04-01
Greenhouse technology is a flexible solution for sustainable year-round cultivation of Tomato (Lycopersicon esculentum Mill), particularly in regions with adverse climate conditions or limited land and resources. Accurate knowledge about plant requirements at different growth stages, and under various light conditions, can contribute to the design of adaptive control strategies for a more cost-effective and competitive production. In this context, different scientific publications have recommended different values of microclimate parameters at different tomato growth stages. This paper provides a detailed summary of optimal, marginal and failure air and root-zone temperatures, relative humidity and vapour pressure deficit for successful greenhouse cultivation of tomato. Graphical representations of the membership function model to define the optimality degrees of these three parameters are included with a view to determining how close the greenhouse microclimate is to the optimal condition. Several production constraints have also been discussed to highlight the short and long-term effects of adverse microclimate conditions on the quality and yield of tomato, which are associated with interactions between suboptimal parameters, greenhouse environment and growth responses.
Kück-Biere, U; von Engelhardt, W
1990-01-01
K+ concentrations were measured in vitro with K+ sensitive microelectrodes in the microclimate at the luminal cell surface of the colon of guinea pigs. The serosal K+ concentration was mostly 5.4 mmol/1, the mucosal K+ concentrations were changed (0, 5, 50, or 70 mmol/l). Under control conditions K+ concentrations in the microclimate of the proximal colon were also low (6-9 mmol/l) and rather independent from K+ concentrations in the bulk luminal solution. In the distal colon K+ concentrations in the microclimate increased from 3.7 mmol/l when no K+ was in the luminal solution, up to 22 mmol/l when the mucosal K+ concentrations was 70 mmol/l. Attempts to decrease K+ conductance of the apical membrane with Ba++, to impair K+ transport with ouabain and to increase the paracellular shunt with deoxycholic acid did not affect K+ concentrations in the microclimate of the proximal colon but decreased K+ concentrations in the distal colon. When valinomycin or triaminopyrimidine were added to the mucosal solution at high K+ concentrations in the luminal solutions the K+ concentration in the microclimate was raised. At low luminal K+ concentrations valinomycin had no effect, triaminopyrimidine significantly diminished K+ concentrations at the cell surface. Regional differences in paracellular shunt conductance and in the preepithelial diffusion barrier are thought to be responsible for the observed differences between the proximal and the distal colon. Obviously, however, further unknown mechanisms have to be involved. PMID:2108077
A cool experimental approach to explain elevational treelines, but can it explain them?
Bader, Maaike Y; Loranger, Hannah; Zotz, Gerhard
2014-09-01
At alpine treeline, trees give way to low-stature alpine vegetation. The main reason may be that tree canopies warm up less in the sun and experience lower average temperatures than alpine vegetation. Low growth temperatures limit tissue formation more than carbon gain, but whether this mechanism universally determines potential treeline elevations is the subject of debate. To study low-temperature limitation in two contrasting treeline tree species, Fajardo and Piper (American Journal of Botany 101: 788-795) grew potted seedlings at ground level or suspended at tree-canopy height (2 m), introducing a promising experimental method for studying the effects of alpine-vegetation and tree-canopy microclimates on tree growth. On the basis of this experiment, the authors concluded that lower temperatures at 2 m caused carbon limitation in one of the species and that treeline-forming mechanisms may thus be taxon-dependent. Here we contest that this important conclusion can be drawn based on the presented experiment, because of confounding effects of extreme root-zone temperature fluctuations and potential drought conditions. To interpret the results of this elegant experiment without logistically challenging technical modifications and to better understand how low temperature leads to treeline formation, studies on effects of fluctuating vs. stable temperatures are badly needed. Other treeline research priorities are interactions between temperature and other climatic factors and differences in microclimate between tree canopies with contrasting morphology and physiology. In spite of our criticism of this particular study, we agree that the development of a universal treeline theory should include continuing explorations of taxon-specific treeline-forming mechanisms. © 2014 Botanical Society of America, Inc.
Isaak, Daniel J; Wenger, Seth J; Young, Michael K
2017-04-01
Temperature profoundly affects ecology, a fact ever more evident as the ability to measure thermal environments increases and global changes alter these environments. The spatial structure of thermalscapes is especially relevant to the distribution and abundance of ectothermic organisms, but the ability to describe biothermal relationships at extents and grains relevant to conservation planning has been limited by small or sparse data sets. Here, we combine a large occurrence database of >23 000 aquatic species surveys with stream microclimate scenarios supported by an equally large temperature database for a 149 000-km mountain stream network to describe thermal relationships for 14 fish and amphibian species. Species occurrence probabilities peaked across a wide range of temperatures (7.0-18.8°C) but distinct warm- or cold-edge distribution boundaries were apparent for all species and represented environments where populations may be most sensitive to thermal changes. Warm-edge boundary temperatures for a native species of conservation concern were used with geospatial data sets and a habitat occupancy model to highlight subsets of the network where conservation measures could benefit local populations by maintaining cool temperatures. Linking that strategic approach to local estimates of habitat impairment remains a key challenge but is also an opportunity to build relationships and develop synergies between the research, management, and regulatory communities. As with any data mining or species distribution modeling exercise, care is required in analysis and interpretation of results, but the use of large biological data sets with accurate microclimate scenarios can provide valuable information about the thermal ecology of many ectotherms and a spatially explicit way of guiding conservation investments. © 2017 by the Ecological Society of America.
The critical role of fire in catchment coevolution in South Eastern Australia
NASA Astrophysics Data System (ADS)
Nyman, P.; Inbar, A.; Lane, P. N. J.; Sheridan, G. J.
2016-12-01
Temperate south east Australian forested uplands are characterised by complex spatial patterns in forest types, soils and fire regimes, even within areas with similar geologies and landscape position. Preliminary measurements and experiments suggest that positive and negative feedbacks between the vegetation, fuels, fire frequency and soil erosion may control the coevolution of these observed system states. Here we propose the hypotheses that in this landscape post-fire soil erosion has played a dominant role in the coevolved system-state combinations of standing biomass, fire frequency and soil depth. To test the hypothesis a 1D simulation model was developed that links together an ecohydrological model to drive the biomass production and water and energy partitioning, a stochastic fire model that is controlled by climate, fuel load and moisture conditions, and a geomorphic model that controls soil production and fluvial and diffusive sediment transport rates. The model was calibrated to the range of existing observed quasi-equalibrium system-states of soil depth, standing biomass, fuel loading and fire frequency using field measurements from 12 instrumented eco-hydrologic microclimate research sites. The long-term partitioning of rainfall into evaporation, transpiration, and streamflow was calibrated against field and literature values. Fuel moisture and micro-climate variables were calibrated to the field microclimate stations. The calibrated model was able to reasonably replicate the observed quasi-equilibrium system-states and hydrologic outputs using current climate forcings operating over a 10,000 year period, providing confidence in the model structure and performance. The model was then used to test the hypothesis stated above, by alternatively including or excluding the post fire erosion process. An alternate hypothesis, whereby the observed system states are dominated by climate related differences in soil production rates was also tested in this way. The results support the hypothesis that feedbacks between fire, ecology, hydrology and geomorphology have played a critical role in the coevolution of south east Australian forested uplands. Similar pyro-eco-hydrologic feedbacks may play a critical role in catchment coevolution in other forested systems globally.
USDA-ARS?s Scientific Manuscript database
We have developed and field-validated an annual inventory model for California landfill CH4 emissions that incorporates both site-specific soil properties and soil microclimate modeling coupled to 0.5o scale global climatic models. Based on 1-D diffusion, CALMIM (California Landfill Methane Inventor...
Siyan Ma; Amy Concilio; Brian Oakley; Malcolm North; Jiquan Chen
2010-01-01
In the western United States, mechanical thinning and prescribed fire are common forest management practices aimed at reducing potential wildfire severity and restoring historic forest structure, yet their effects on forestmicroclimate conditions are not well understood. We collected microclimate data between 1998 and 2003 in amixed-coniferforest in California's...
W.B. Sutton; Y. Wang; C.J. Schweitzer; D.A. Steen
2014-01-01
Understanding the impacts of disturbances in forest ecosystems is essential for long-term biodiversity conservation. Many studies have evaluated wildlife responses to various disturbances but most generally do not use changes in microclimate features or crohabitat structure to explain these responses. We examined lizard responses to two common forest management...
Eben N. Broadbent; Angélica M. Almeyda Zambrano; Gregory P. Asner; Christopher B. Field; Brad E. Rosenheim; Ty Kennedy-Bowdoin; David E. Knapp; David Burke; Christian Giardina; Susan Cordell
2014-01-01
We develop and validate a high-resolution three-dimensional model of light and air temperature for a tropical forest interior in Hawaii along an elevation gradient varying greatly in structure but maintaining a consistent species composition. Our microclimate models integrate high-resolution airborne waveform light detection and ranging data (LiDAR) and hyperspectral...
Riparian microclimate and stream temperature: thinning and buffer-width influences
Paul D. Anderson
2013-01-01
Th inning of 30- to 70-year-old Douglas-fir (Pseudotsuga menziesii) stands is a common silvicultural activity on federal forest lands in Washington and Oregon west of the Cascade Range crest. Decreases in forest cover lead to alterations of site energy balances resulting in changes to understory and stream channel microclimates. Uncut vegetative...
Intestinal alkaline phosphatase regulates protective surface microclimate pH in rat duodenum.
Mizumori, Misa; Ham, Maggie; Guth, Paul H; Engel, Eli; Kaunitz, Jonathan D; Akiba, Yasutada
2009-07-15
Regulation of localized extracellular pH (pH(o)) maintains normal organ function. An alkaline microclimate overlying the duodenal enterocyte brush border protects the mucosa from luminal acid. We hypothesized that intestinal alkaline phosphatase (IAP) regulates pH(o) due to pH-sensitive ATP hydrolysis as part of an ecto-purinergic pH regulatory system, comprised of cell-surface P2Y receptors and ATP-stimulated duodenal bicarbonate secretion (DBS). To test this hypothesis, we measured DBS in a perfused rat duodenal loop, examining the effect of the competitive alkaline phosphatase inhibitor glycerol phosphate (GP), the ecto-nucleoside triphosphate diphosphohydrolase inhibitor ARL67156, and exogenous nucleotides or P2 receptor agonists on DBS. Furthermore, we measured perfusate ATP concentration with a luciferin-luciferase bioassay. IAP inhibition increased DBS and luminal ATP output. Increased luminal ATP output was partially CFTR dependent, but was not due to cellular injury. Immunofluorescence localized the P2Y(1) receptor to the brush border membrane of duodenal villi. The P2Y(1) agonist 2-methylthio-ADP increased DBS, whereas the P2Y(1) antagonist MRS2179 reduced ATP- or GP-induced DBS. Acid perfusion augmented DBS and ATP release, further enhanced by the IAP inhibitor l-cysteine, and reduced by the exogenous ATPase apyrase. Furthermore, MRS2179 or the highly selective P2Y(1) antagonist MRS2500 co-perfused with acid induced epithelial injury, suggesting that IAP/ATP/P2Y signalling protects the mucosa from acid injury. Increased DBS augments IAP activity presumably by raising pH(o), increasing the rate of ATP degradation, decreasing ATP-mediated DBS, forming a negative feedback loop. The duodenal epithelial brush border IAP-P2Y-HCO(3-) surface microclimate pH regulatory system effectively protects the mucosa from acid injury.
Differences in physical growth of Aymara and Quechua children living at high altitude in Peru.
de Meer, K; Bergman, R; Kusner, J S; Voorhoeve, H W
1993-01-01
Physical growth of Amerindian children living in two Aymara and three Quechua peasant communities in the Andean highlands of southern Peru (altitude 3,810-3,840 m) was studied, taking into account differences in the microclimate, agronomic situation, and sociodemographic variables. Anthropometric measurements were taken in 395 children aged under 14 years of age in a sample of 151 families in these communities, who were surveyed for sociodemographic variables as well. Data on the land system were available for 77 families. In comparison with reference populations from the United States (NCHS) and The Netherlands, stature, weight, head circumference, and midupper arm circumference (but not weight for stature) in the sample children were reduced. Growth retardation increased after the age of 1 year. Stature and weight in the present sample were very similar compared with previously published data on growth of rural Aymara children living near Lake Titicaca in Bolivia. Head circumference, midupper arm circumference, and weight for stature were significantly larger in Aymara children compared with Quechua children. Land was significantly more fragmented in Aymara compared with Quechua families, but amount of land owned was not different. Perinatal and infant mortality was elevated in Aymara vs. Quechua communities. Most families in Aymara communities used protected drinking water. One Quechua community had a severe microclimate, grim economic outlook, and weak social cohesion. Children in this community showed significant reductions in weight and midupper arm circumference compared with their peers in the other communities. We conclude that (presumably nutritionally mediated) intervillage and Aymara-Quechua differences in childhood physical growth existed in this rural high-altitude population in Peru and were associated with microclimate and the village economy, sociodemographic factors, and differences in the land system.
Runeman, Bo; Rybo, Göran; Forsgren-Brusk, Ulla; Larkö, Olle; Larsson, Peter; Faergemann, Jan
2005-01-01
The aim of the present study was to investigate if tight-fitting underwear (string panties) equipped with string panty liners affected the vulvar skin microenvironment differently to regular panties with standard panty liners. Thirty-two healthy women participated in a crossover study where temperature, humidity, surface pH and aerobic microflora were measured on vulvar skin. Vulvar skin temperature was 35.2 +/- 0.19 (mean +/- SEM) and 35.3 +/- 0.17 degrees C, respectively, for the two underwear systems. Mean humidity and mean skin surface pH at vulvar skin did not differ between the two systems. Barely noticeable differences were found for the aerobic microflora both at labium majus and at perineum. The mean total number of microorganisms in the two different panty liners was the same, 6.0 +/- 0.15 and 6.0 +/- 0.16, respectively (log CFU per panty liner). The differences in panty and panty liner design studied seem to have negligible impact on the vulvar skin microclimate, skin surface pH and aerobic microflora. No support was found for the assumption that a string panty system would result in higher contamination of vulvar skin by anorectal microflora.
NASA Astrophysics Data System (ADS)
Tucker, C.; Reed, S.; Howell, A.
2017-12-01
Carbon cycling associated with biological soil crusts, which occur in interspaces between vascular plants in drylands globally, may be an important part of the coupled climate-carbon cycle of the Earth system. A major challenge to understanding CO2 fluxes in these systems is that much of the biotic and biogeochemical activity occurs in the upper few mm of the soil surface layer (i.e., the `mantle of fertility'), which exhibits highly dynamic and difficult to measure temperature and moisture fluctuations. Here, we report data collected in a cool desert ecosystem over one year using a multi-sensor approach to simultaneously measuring temperature and moisture of the biocrust surface layer (0-2 mm), and the deeper soil profile (5-20 cm), concurrent with automated measurement of surface soil CO2 effluxes. Our results illuminate robust relationships between microclimate and field CO2 pulses that have previously been difficult to detect and explain. The temperature of the biocrust surface layer was highly variable, ranging from minimum of -9 °C in winter to maximum of 77 °C in summer with a maximum diurnal range of 61 °C. Temperature cycles were muted deeper in the soil profile. During summer, biocrust and soils were usually hot and dry and CO2 fluxes were tightly coupled to pulse wetting events experienced at the biocrust surface, which consistently resulted in net CO2 efflux (i.e., respiration). In contrast, during the winter, biocrust and soils were usually cold and moist, and there was sustained net CO2 uptake via photosynthesis by biocrust organisms, although during cold dry periods CO2 fluxes were minimal. During the milder spring and fall seasons, short wetting events drove CO2 loss, while sustained wetting events resulted in net CO2 uptake. Thus, the upper and lower bounds of net CO2 exchange at a point in time were functions of the seasonal temperature regime, while the actual flux within those bounds was determined by the magnitude and duration of biocrust and soil wetting events. These patterns reflect both the low temperature sensitivity and slow initiation in response to wetting of photosynthesis compared to respiration by biocrust organisms. Our study highlights the importance of cool and cold periods for C uptake in biocrusted soils of the Colorado Plateau.
Zarzo, Manuel; Fernández-Navajas, Angel; García-Diego, Fernando-Juan
2011-01-01
We describe the performance of a microclimate monitoring system that was implemented for the preventive conservation of the Renaissance frescoes in the apse vault of the Cathedral of Valencia, that were restored in 2006. This system comprises 29 relative humidity (RH) and temperature sensors: 10 of them inserted into the plaster layer supporting the fresco paintings, 10 sensors in the walls close to the frescoes and nine sensors measuring the indoor microclimate at different points of the vault. Principal component analysis was applied to RH data recorded in 2007. The analysis was repeated with data collected in 2008 and 2010. The resulting loading plots revealed that the similarities and dissimilarities among sensors were approximately maintained along the three years. A physical interpretation was provided for the first and second principal components. Interestingly, sensors recording the highest RH values correspond to zones where humidity problems are causing formation of efflorescence. Recorded data of RH and temperature are discussed according to Italian Standard UNI 10829 (1999). PMID:22164100
Insect Infestations Linked to Shifts in Microclimate: Important Climate Change Implications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Classen, Aimee T; Hart, Stephen C; Whitham, Thomas G
Changes in vegetation due to drought-influenced herbivory may influence microclimate in ecosystems. In combination with studies of insect resistant and susceptible trees, we used long-term herbivore removal experiments with two herbivores of pinon (Pinus edulis Endelm.) to test the general hypothesis that herbivore alteration of plant architecture affects soil microclimate, a major driver of ecosystem-level processes. The pinon needle scale (Matsucoccus acalyptus, Herbert) attacks needles of juvenile trees causing them to develop an open crown. In contrast, the stem-boring moth (Dioryctria albovittella Hulst.) kills the terminal shoots of mature trees, causing the crown to develop a dense form. Our studiesmore » focused on how the microclimate effects of these architectural changes are likely to accumulate over time. Three patterns emerged: (1) scale herbivory reduced leaf area index (LAI) of susceptible trees by 39%, whereas moths had no effect on LAI; (2) scale herbivory increased soil moisture and temperature beneath susceptible trees by 35 and 26%, respectively, whereas moths had no effect; and (3) scale and moth herbivory decreased crown interception of precipitation by 51 and 29%, respectively. From these results, we conclude: (1) the magnitude of scale effects on soil moisture and temperature is large, similar to global change scenarios, and sufficient to drive changes in ecosystem processes. (2) The larger sizes of moth-susceptible trees apparently buffered them from most microclimate effects of herbivory, despite marked changes in crown architecture. (3) The phenotypic expression of susceptibility or resistance to scale insects extends beyond plant-herbivore interactions to the physical environment.« less
Andrew D. George; Frank R. Thompson; John. Faaborg
2015-01-01
A spatial mismatch exists between regional climate models and conditions experienced by individual organisms. We demonstrate an approach to downscaling air temperatures for site-level studies using airborne LiDAR data and remote microclimate loggers. In 2012-2013, we established a temperature logger network in the forested region of central Missouri, USA, and obtained...
Spatial and temporal variability of canopy microclimate in a Sierra Nevada riparian forest
T. Rambo; M. North
2008-01-01
Past riparian microclimate studies have measured changes horizontally from streams, but not vertically through the forest canopy. We recorded temperature and relative humidity for a year along a two-dimensional grid of 24 data-loggers arrayed up to 40 m height in four trees 2 - 30 m slope distance from a perennial second order stream in...
Keith Reinhardt; William K. Smith
2010-01-01
The red spruce-Fraser fir ecosystem (Picea rubens Sarg.-Abies fraseri [Pursh] Poir.) of the southern Appalachian mountains is a temperate zone cloud forest immersed in clouds for 30 to 40 percent of a typical summer day, and experiencing immersion on about 65 percent of all days annually. We compared the microclimate,...
Paul E. Hennon; David V. D' Amore; Dustin T. Witter; Melinda B. Lamb
2010-01-01
Site factors predispose yellow-cedar (Chamaecyparis nootkatensis D. Don (Spach)) to a widespread climate-induced mortality in southeast Alaska. We investigated the influence of canopy cover and snow on microclimate at two small watersheds across a range of declining yellow-cedar stands on Baranof and Chichagof Islands in southeast Alaska. Two...
Sedov, A V; Kustov, V V; Surovtsev, N A; Lukicheva, T A; Akin'shin, A V; Nazarov, L Iu; Stroganov, V P
1991-01-01
Basing on experimental data, it was established that single administration of 0.5 mg bemitil increased human resistance to carbon oxide in concentration 300 mg/m3. The use of bemitil optimized human body state in the conditions of the complex influence of carbon oxide and extreme heating microclimate.
Natural disturbance reduces disease risk in endangered rainforest frog populations
Roznik, Elizabeth A.; Sapsford, Sarah J.; Pike, David A.; Schwarzkopf, Lin; Alford, Ross A.
2015-01-01
Natural disturbances can drive disease dynamics in animal populations by altering the microclimates experienced by hosts and their pathogens. Many pathogens are highly sensitive to temperature and moisture, and therefore small changes in habitat structure can alter the microclimate in ways that increase or decrease infection prevalence and intensity in host populations. Here we show that a reduction of rainforest canopy cover caused by a severe tropical cyclone decreased the risk of endangered rainforest frogs (Litoria rheocola) becoming infected by a fungal pathogen (Batrachochytrium dendrobatidis). Reductions in canopy cover increased the temperatures and rates of evaporative water loss in frog microhabitats, which reduced B. dendrobatidis infection risk in frogs by an average of 11–28% in cyclone-damaged areas, relative to unaffected areas. Natural disturbances to the rainforest canopy can therefore provide an immediate benefit to frogs by altering the microclimate in ways that reduce infection risk. This could increase host survival and reduce the probability of epidemic disease outbreaks. For amphibian populations under immediate threat from this pathogen, targeted manipulation of canopy cover could increase the availability of warmer, drier microclimates and therefore tip the balance from host extinction to coexistence. PMID:26294048
Natural disturbance reduces disease risk in endangered rainforest frog populations.
Roznik, Elizabeth A; Sapsford, Sarah J; Pike, David A; Schwarzkopf, Lin; Alford, Ross A
2015-08-21
Natural disturbances can drive disease dynamics in animal populations by altering the microclimates experienced by hosts and their pathogens. Many pathogens are highly sensitive to temperature and moisture, and therefore small changes in habitat structure can alter the microclimate in ways that increase or decrease infection prevalence and intensity in host populations. Here we show that a reduction of rainforest canopy cover caused by a severe tropical cyclone decreased the risk of endangered rainforest frogs (Litoria rheocola) becoming infected by a fungal pathogen (Batrachochytrium dendrobatidis). Reductions in canopy cover increased the temperatures and rates of evaporative water loss in frog microhabitats, which reduced B. dendrobatidis infection risk in frogs by an average of 11-28% in cyclone-damaged areas, relative to unaffected areas. Natural disturbances to the rainforest canopy can therefore provide an immediate benefit to frogs by altering the microclimate in ways that reduce infection risk. This could increase host survival and reduce the probability of epidemic disease outbreaks. For amphibian populations under immediate threat from this pathogen, targeted manipulation of canopy cover could increase the availability of warmer, drier microclimates and therefore tip the balance from host extinction to coexistence.
[Microclimate and comfortable degree of Shanghai urban open spaces in summer].
Cao, Dan; Zhou, Li-chen; Mao, Yi-wei; Li, Yin; Liu, Yi-ning; Wang, Tian-hou
2008-08-01
Based on the observation data of air temperature, relative humidity, wind speed, and solar radiation from May to August 2006, the regulation effects of five types of open spaces (square, fountain, grassplot, corridor, and woodland) in Shanghai urban districts on the microclimate were analyzed, and discomfort index (DI) was introduced to evaluate the effects of these five types of open spaces on human body' s comfortable degree. The results showed that there existed definite differences in the air temperature and relative humidity among the open spaces, with the mean temperature decreased in the order of square > grassplot > fountain > corridor > woodland, and the mean relative humidity decreased in the order of woodland > corridor > fountain > grassplot > square. The area of the square, the wind speed and direction near the fountain, the grass species on the grass-plot, the width and tree coverage of the corridor, and the tree coverage and canopy height of the woodland had significant correlations with the microclimate parameters of corresponding open spaces. Comparing with other three types of open spaces, woodland and corridor had better regulation effects on the microclimate via shading, decreasing air temperature, and increasing relative humidity.
Cavity types and microclimate: implications for ecological, evolutionary, and conservation studies.
Amat-Valero, M; Calero-Torralbo, M A; Václav, R; Valera, F
2014-11-01
The abiotic conditions of the immediate environment of organisms are key factors for a better understanding of ecological and evolutionary processes. Yet, information in this regard is biased towards some habitat types, landscapes, and organisms. Here, we present a 2-year comparative study of the microclimatic properties (temperature, relative humidity, and their fluctuation) of three cavity types (nest boxes, cavities in bridges, and burrows in sandy cliffs) in an arid environment. We found marked and consistent months-long differences in microclimate among the three cavity types. Nest boxes were colder than the other cavity types, with temperature oscillations being an order of magnitude higher than in other cavity types. In contrast, microclimate was very stable in burrows and cavities in bridges, the former being generally warmer and drier than the latter. We also discuss the biological implications of microclimatic conditions and its variation in different cavity types by presenting two case studies, namely the temperature-humidity index and water vapor pressure during the hatching period of an endotherm and the chilling period during the diapause of an ectotherm ectoparasite. We stress the need for comparative studies of the same organisms subjected to different microclimates given the important ecological, evolutionary, and conservation implications.
Microclimate and development of pressure ulcers and superficial skin changes.
Yusuf, Saldy; Okuwa, Mayumi; Shigeta, Yoshie; Dai, Misako; Iuchi, Terumi; Rahman, Sulaiman; Usman, Awaluddin; Kasim, Sukmawati; Sugama, Junko; Nakatani, Toshio; Sanada, Hiromi
2015-02-01
This study aims to evaluate the microclimate and development of pressure ulcers and superficial skin changes. A prospective cohort study was conducted in an acute care ward in Indonesia. Risk factors for pressure ulcers and superficial skin changes were identified based on the Bergstrom Braden conceptual model. Microclimate data were collected every 3 days for 15 days while the development of pressure ulcers and superficial skin changes was observed every day. Pressure ulcers and superficial skin changes were developed in 20 of the 71 participants. Total mean difference in skin temperature was higher for patients with pressure ulcers and superficial skin changes (0·9 ± 0·6°C) compared with controls (0·6 ± 0·8°C) (P = 0·071). Binary logistic regression predictor values for pressure ulcers and superficial skin changes were 0·111 for type of sheet and 0·347 for Braden Scale results. In conclusion, difference in skin temperature seems to be a predictor for pressure ulcer development and superficial skin changes, while synthetic fibre sheets are able to maintain a beneficial microclimate. © 2013 The Authors. International Wound Journal © 2013 Medicalhelplines.com Inc and John Wiley & Sons Ltd.
Microclimatic Performance of a Free-Air Warming and CO2 Enrichment Experiment in Windy Wyoming, USA
LeCain, Daniel; Smith, David; Morgan, Jack; Kimball, Bruce A.; Pendall, Elise; Miglietta, Franco
2015-01-01
In order to plan for global changing climate experiments are being conducted in many countries, but few have monitored the effects of the climate change treatments (warming, elevated CO2) on the experimental plot microclimate. During three years of an eight year study with year-round feedback-controlled infra-red heater warming (1.5/3.0°C day/night) and growing season free-air CO2 enrichment (600 ppm) in the mixed-grass prairie of Wyoming, USA, we monitored soil, leaf, canopy-air, above-canopy-air temperatures and relative humidity of control and treated experimental plots and evaluated ecologically important temperature differentials. Leaves were warmed somewhat less than the target settings (1.1 & 1.5°C day/night) but soil was warmed more creating an average that matched the target settings extremely well both during the day and night plus the summer and winter. The site typically has about 50% bare or litter covered soil, therefore soil heat transfer is more critical than in dense canopy ecosystems. The Wyoming site commonly has strong winds (5 ms-1 average) and significant daily and seasonal temperature fluctuations (as much as 30°C daily) but the warming system was nearly always able to maintain the set temperatures regardless of abiotic variation. The within canopy-air was only slightly warmed and above canopy-air was not warmed by the system, therefore convective warming was minor. Elevated CO2 had no direct effect nor interaction with the warming treatment on microclimate. Relative humidity within the plant canopy was only slightly reduced by warming. Soil water content was reduced by warming but increased by elevated CO2. This study demonstrates the importance of monitoring the microclimate in manipulative field global change experiments so that critical physiological and ecological conclusions can be determined. Highly variable energy demand fluctuations showed that passive IR heater warming systems will not maintain desired warming for much of the time. PMID:25658313
Microclimatic performance of a free-air warming and CO₂ enrichment experiment in windy Wyoming, USA
DOE Office of Scientific and Technical Information (OSTI.GOV)
LeCain, Daniel; Smith, David; Morgan, Jack
In order to plan for global changing climate experiments are being conducted in many countries, but few have monitored the effects of the climate change treatments (warming, elevated CO₂) on the experimental plot microclimate. During three years of an eight year study with year-round feedback-controlled infra-red heater warming (1.5/3.0°C day/night) and growing season free-air CO₂ enrichment (600 ppm) in the mixed-grass prairie of Wyoming, USA, we monitored soil, leaf, canopy-air, above-canopy-air temperatures and relative humidity of control and treated experimental plots and evaluated ecologically important temperature differentials. Leaves were warmed somewhat less than the target settings (1.1 & 1.5°C day/night)more » but soil was warmed more creating an average that matched the target settings extremely well both during the day and night plus the summer and winter. The site typically has about 50% bare or litter covered soil, therefore soil heat transfer is more critical than in dense canopy ecosystems. The Wyoming site commonly has strong winds (5 ms⁻¹ average) and significant daily and seasonal temperature fluctuations (as much as 30°C daily) but the warming system was nearly always able to maintain the set temperatures regardless of abiotic variation. The within canopy-air was only slightly warmed and above canopy-air was not warmed by the system, therefore convective warming was minor. Elevated CO₂ had no direct effect nor interaction with the warming treatment on microclimate. Relative humidity within the plant canopy was only slightly reduced by warming. Soil water content was reduced by warming but increased by elevated CO₂. This study demonstrates the importance of monitoring the microclimate in manipulative field global change experiments so that critical physiological and ecological conclusions can be determined. Highly variable energy demand fluctuations showed that passive IR heater warming systems will not maintain desired warming for much of the time.« less
Microclimatic performance of a free-air warming and CO₂ enrichment experiment in windy Wyoming, USA
LeCain, Daniel; Smith, David; Morgan, Jack; ...
2015-02-06
In order to plan for global changing climate experiments are being conducted in many countries, but few have monitored the effects of the climate change treatments (warming, elevated CO₂) on the experimental plot microclimate. During three years of an eight year study with year-round feedback-controlled infra-red heater warming (1.5/3.0°C day/night) and growing season free-air CO₂ enrichment (600 ppm) in the mixed-grass prairie of Wyoming, USA, we monitored soil, leaf, canopy-air, above-canopy-air temperatures and relative humidity of control and treated experimental plots and evaluated ecologically important temperature differentials. Leaves were warmed somewhat less than the target settings (1.1 & 1.5°C day/night)more » but soil was warmed more creating an average that matched the target settings extremely well both during the day and night plus the summer and winter. The site typically has about 50% bare or litter covered soil, therefore soil heat transfer is more critical than in dense canopy ecosystems. The Wyoming site commonly has strong winds (5 ms⁻¹ average) and significant daily and seasonal temperature fluctuations (as much as 30°C daily) but the warming system was nearly always able to maintain the set temperatures regardless of abiotic variation. The within canopy-air was only slightly warmed and above canopy-air was not warmed by the system, therefore convective warming was minor. Elevated CO₂ had no direct effect nor interaction with the warming treatment on microclimate. Relative humidity within the plant canopy was only slightly reduced by warming. Soil water content was reduced by warming but increased by elevated CO₂. This study demonstrates the importance of monitoring the microclimate in manipulative field global change experiments so that critical physiological and ecological conclusions can be determined. Highly variable energy demand fluctuations showed that passive IR heater warming systems will not maintain desired warming for much of the time.« less
Release of Oregon white oak from overtopping Douglas-fir: effects on soil water and microclimate.
W.D. Devine; C.A. Harrington
2007-01-01
Many former Oregon white oak woodland and savanna stands in the coastal Pacific Northwest have been invaded and subsequently overtopped by Douglas-fir during the past century. We examined soil water and microclimate conditions near overtopped oak trees and near oak trees that had been released from Douglas-fir. In each of the three study years, volumetric soil water...
USDA-ARS?s Scientific Manuscript database
Microclimate variables were integrated over a six-month period during which blueberry (Vaccinium corymbosum cv. Liberty) bushes were grown in 51-cm high, 20-cm diameter round grow tubes (opaque or translucent) on a sawdust mulch-covered raised bed with the mulch incorporated into tilled soil. Grow t...
Scholl, M.A.; Gingerich, S.B.; Tribble, G.W.
2002-01-01
Stable isotopes of precipitation, ground water and surface water measured on the windward side of East Maui from 0 to 3055 m altitude were used to determine recharge sources for stream flow and ground water. Correct interpretation of the hydrology using rainfall ??18O gradients with altitude required consideration of the influence of fog, as fog samples had isotopic signatures enriched by as much as 3??? in ??18O and 21??? in ??D compared to volume-weighted average precipitation at the same altitude. The isotopic analyses suggested that fog drip was a major component of stream flow and shallow ground water at higher altitudes in the watershed. 18O/altitude gradients in rainfall were comparable for similar microclimates on Maui (this study) and Hawaii Island (1990-1995 study), however, East Maui ??18O values for rain in trade-wind and high-altitude microclimates were enriched compared to those from Hawaii Island. Isotopes were used to interpret regional hydrology in this volcanic island aquifer system. In part of the study area, stable isotopes indicate discharge of ground water recharged at least 1000 m above the sample site. This deep-flowpath ground water was found in springs from sea level up to 240 m altitude, indicating saturation to altitudes much higher than a typical freshwater lens. These findings help in predicting the effects of ground water development on stream flow in the area. Published by Elsevier Science B.V.
USDA-ARS?s Scientific Manuscript database
One of our three program goals for this USDA-ARS-CRIS project is to determine the effects of vineyard and vine microclimate (sunlight, temperature, humidity, etc) upon fruit development, vine productivity, and fruit quality, particularly phenolic compounds. Plant phenolics are important due to their...
Woods, H Arthur; Dillon, Michael E; Pincebourde, Sylvain
2015-12-01
We analyze the effects of changing patterns of thermal availability, in space and time, on the performance of small ectotherms. We approach this problem by breaking it into a series of smaller steps, focusing on: (1) how macroclimates interact with living and nonliving objects in the environment to produce a mosaic of thermal microclimates and (2) how mobile ectotherms filter those microclimates into realized body temperatures by moving around in them. Although the first step (generation of mosaics) is conceptually straightforward, there still exists no general framework for predicting spatial and temporal patterns of microclimatic variation. We organize potential variation along three axes-the nature of the objects producing the microclimates (abiotic versus biotic), how microclimates translate macroclimatic variation (amplify versus buffer), and the temporal and spatial scales over which microclimatic conditions vary (long versus short). From this organization, we propose several general rules about patterns of microclimatic diversity. To examine the second step (behavioral sampling of locally available microclimates), we construct a set of models that simulate ectotherms moving on a thermal landscape according to simple sets of diffusion-based rules. The models explore the effects of both changes in body size (which affect the time scale over which organisms integrate operative body temperatures) and increases in the mean and variance of temperature on the thermal landscape. Collectively, the models indicate that both simple behavioral rules and interactions between body size and spatial patterns of thermal variation can profoundly affect the distribution of realized body temperatures experienced by ectotherms. These analyses emphasize the rich set of problems still to solve before arriving at a general, predictive theory of the biological consequences of climate change. Copyright © 2014 Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Christensen, Mette K.; Lund, Ole
2014-01-01
Scholarly communities are dependent on and often measured by their ability to attract and develop doctoral students. Recent literature suggests that most scholarly communities entail ecological niches in which the doctoral students learn the codes and practices of research. In this article, we explore the microclimate in an ecological niche of…
Lapko, I V; Kir'iakov, V A; Antoshina, L I; Pavlovskaia, N A; Kondratovich, S V
2014-01-01
The authors studied influence of vibration, noise, physical overexertion and microclimate on carbohydrates metabolism and insulin resistance in metal mining industry workers. Findings are that vibration disease appeared to have maximal effect on insulin resistance test results and insulin level. The authors suggested biomarkers for early diagnosis of insulin resistance disorders in metal mining industry workers.
Pierce, K.L.; Colman, Steven M.
1986-01-01
Examines the effects of scarp size (height) and orientation (microclimate) by keeping constant variables such as age, lithology, and regional climate. For scarps 2m high, the degradation rate on S-facing scarps is 2 times that on N-facing scarps; for 10-m scarps, it is 5 times. Scarp morphology may be used to estimate age. -from Authors
Li, Yingnan; Kang, Wanmo; Han, Yiwen; Song, Youngkeun
2018-01-23
Fragmented forests generate a variety of forest edges, leading to microclimates in the edge zones that differ from those in the forest interior. Understanding microclimatic variation is an important consideration for managers because it helps when making decisions about how to restrict the extent of edge effects. Thus, our study attempted to characterize the changing microclimate features at an urban forest edge located on Mt. Gwanak, Seoul, South Korea. We examined edge effects on air temperature, relative humidity, soil temperature, soil moisture, and photosynthetically active radiation (PAR) during the hottest three consecutive days in August 2016. Results showed that each variable responded differently to the edge effects. This urban forest edge had an effect on temporal changes at a diurnal scale in all microclimate variables, except soil moisture. In addition, all variables except relative humidity were significantly influenced by the edge effect up to 15 m inward from the forest boundary. The relative humidity fluctuated the most and showed the deepest extent of the edge effect. Moreover, the edge widths calculated from the relative humidity and air temperature both peaked in the late afternoon (16:00 h). Our findings provide a reference for forest managers in designing urban forest zones and will contribute to the conservation of fragmented forests in urban areas.
Reeves, Ian; Emery, R J Neil
2007-11-01
Seasonal patterns of cytokinins (CKs) and microclimate were examined in the upper, middle and lower canopy layers of mature Acer saccharum Marsh. (sugar maple) trees to elucidate the potential role of CKs in the mediation of gas exchange. The upper canopy showed a distinctly dissimilar microclimate from the middle and lower canopy layers with higher photosynthetically active radiation and wind speed, but showed no corresponding differences in transpiration (E) or stomatal conductance (g(s)). Although E and g(s) tended to be higher in the upper canopy than in the middle and lower canopies, the differences were not significant, indicating regulation beyond the passive response to changes in microclimate. The upper canopy accumulated significantly higher concentrations of CKs, predominantly as ribosides, and all canopy layers showed distinct seasonal patterns in CK profiles. Multiple regression models showed significant relationships between both g(s) and E and foliar CK concentration, although these relationships varied among canopy layers. The relationships were strongest in the middle and lower canopy layers where there was less fluctuation in leaf water status and less variability in abiotic variables. The relationships between gas exchange parameters and leaf CK concentration began to decouple near the end of the growing season as foliar phytohormone concentrations changed with the approach of dormancy.
Thapa, Sushil; Stewart, Bob A; Xue, Qingwu; Chen, Yuanquan
2017-01-01
Cultivar selection, planting geometry, and plant population are the key factors determining grain sorghum yields in water deficit areas. The objective of this study was to investigate whether clump geometry (three plants clustered) improves microclimate within crop canopy when plants are grown under varying water levels. In a 2-yr sorghum (Sorghum bicolor L. Moench) greenhouse study, plants were grown at two geometries (clump and conventional evenly spaced planting, ESP), two water levels (high and low, representing well-watered and water-limited condition, respectively), and three soil surface treatments (lid covered, straw-mulched, and bare). Air temperature and relative humidity (RH) within the plant canopy were measured every five minutes at different growth stages. Mean vapor pressure deficits (VPDs) within the clumps were consistently lower than those for ESPs, indicating that clumps improved the microclimate. Clumps had significantly higher harvest index (HI) compared to ESPs (0.48 vs. 0.43), which was largely due to clumps having an average of 0.4 tillers per plant compared to 1.2 tillers per plant for ESPs. Grain yield in the current study was similar between clumps and ESPs. However, our results suggest that improved microclimate was likely a reason for clumps producing significantly higher grain yields compared to ESPs in previous studies.
Manipulating plant geometry to improve microclimate, grain yield, and harvest index in grain sorghum
Stewart, Bob A.; Xue, Qingwu; Chen, Yuanquan
2017-01-01
Cultivar selection, planting geometry, and plant population are the key factors determining grain sorghum yields in water deficit areas. The objective of this study was to investigate whether clump geometry (three plants clustered) improves microclimate within crop canopy when plants are grown under varying water levels. In a 2-yr sorghum (Sorghum bicolor L. Moench) greenhouse study, plants were grown at two geometries (clump and conventional evenly spaced planting, ESP), two water levels (high and low, representing well-watered and water-limited condition, respectively), and three soil surface treatments (lid covered, straw-mulched, and bare). Air temperature and relative humidity (RH) within the plant canopy were measured every five minutes at different growth stages. Mean vapor pressure deficits (VPDs) within the clumps were consistently lower than those for ESPs, indicating that clumps improved the microclimate. Clumps had significantly higher harvest index (HI) compared to ESPs (0.48 vs. 0.43), which was largely due to clumps having an average of 0.4 tillers per plant compared to 1.2 tillers per plant for ESPs. Grain yield in the current study was similar between clumps and ESPs. However, our results suggest that improved microclimate was likely a reason for clumps producing significantly higher grain yields compared to ESPs in previous studies. PMID:28264051
DOE Office of Scientific and Technical Information (OSTI.GOV)
Coulson, S.; Hodkinson, I.D.; Stathdee, A.
1993-01-01
Small polythene tents were used to simulate the effects of climate warming on two contrasting vegetation types (polar semi-desert and tundra heath) at Ny Alesund, Spitzbergen, Svalbard. Temperature microclimates are compared within and without tents and between sites with contrasting vegetation types. Summer temperatures were increased by about 5[degrees]C in the vegetation mat and by about 2[degrees]C in the soil at 3 cm depth. Cumulative day degrees above zero were enhanced by around 35% in the vegetation and by around 9% in the soil. Soil temperatures were greatly influenced by the nature of the overlying vegetation, which at one ofmore » the sites appeared to act as an efficient thermal insulator, preventing heat conductance into the soil from above and enhancing thermal contact between the upper soil layer and the cooling permafrost below. The significance of the observed temperature differences for the ecology of the plants and invertebrates is discussed. 21 refs., 3 figs., 2 tabs.« less
Local climate on and around a glacier - a case study of Storglaciären
NASA Astrophysics Data System (ADS)
Konya, K.; Hock, R.
2004-12-01
It is sometimes necessary to transform the climate data from a station to another station on a glacier. However, it is generally not so easy to do so since a glacier has its own specific microclimate. At Storglaciären in the summer 2003, air temperature and wind speed were measured at two weather stations set up near the center of the glacier and at the ridge of the bordering valley wall 300 m above the glacier surface. Additional continuous measurements are made at a weather station at Tarfala Research Station, which is located 1 km down glacier (1135 m a.s.l.). The result show a slight temperature difference between ridge and glacier stations because of the cooling effect by the glacier. Thus, temperature lapse rate is different. Wind speed on the ridge was higher than the other two in most cases, and the difference was largest during periods of high wind speed. The correlation between wind speed at the ridge and the other sites is weak.
Portable System for Monitoring the Microclimate in the Footwear-Foot Interface
Sandoval-Palomares, José de Jesús; Yáñez-Mendiola, Javier; Gómez-Espinosa, Alfonso; López-Vela, José Martin
2016-01-01
A new, continuously-monitoring portable device that monitors the diabetic foot has shown to help in reduction of diabetic foot complications. Persons affected by diabetic foot have shown to be particularly sensitive in the plantar surface; this sensitivity coupled with certain ambient conditions may cause dry skin. This dry skin leads to the formation of fissures that may eventually result in a foot ulceration and subsequent hospitalization. This new device monitors the micro-climate temperature and humidity areas between the insole and sole of the footwear. The monitoring system consists of an array of ten sensors that take readings of relative humidity within the range of 100% ± 2% and temperature within the range of −40 °C to 123.8 ± 0.3 °C. Continuous data is collected using embedded C software and the recorded data is processed in Matlab. This allows for the display of data; the implementation of the iterative Gauss-Newton algorithm method was used to display an exponential response curve. Therefore, the aim of our system is to obtain feedback data and provide the critical information to various footwear manufacturers. The footwear manufactures will utilize this critical information to design and manufacture diabetic footwear that reduce the risk of ulcers in diabetic feet. PMID:27399718
Gefen, Amit
2011-08-01
In this study, a mathematical model is developed for analyzing the effects of the microclimate on skin tolerance to superficial pressure ulcers (SPUs). The modeling identified the following factors as such that decrease the tolerance of skin to SPUs: (i) increase in the skin temperature, (ii) increase in the ambient temperature, (iii) increase in the relative humidity, (iv) increase in the skin-support (or skin-clothing-support) contact pressures, and (v) decrease in permeabilities of the materials contacting the skin or being close to it, e.g. the covering sheet of the support and clothing. The modeling is consistent with relevant empirical findings and clinical observations documented in the literature, explains them from a basic science aspect, and can be further developed for design of interventions, safer patient clothing and supports that consider the optimization of microclimate factors. Copyright © 2010 Tissue Viability Society. Published by Elsevier Ltd. All rights reserved.
ERIC Educational Resources Information Center
Lyons, Zachary
2010-01-01
Issues related to supporting the language of schooling have become important social and educational policy concerns in Ireland. This article reports on a three-year investigation of the micro-climate of English language support provision in 70 post-primary schools since 2007 and highlights potential points of leverage in the educational system for…
Ha, M; Tokura, H; Tanaka, Y; Holmér, I
1996-01-01
Thermophysiological responses and clothing microclimate under the influences of different underwear materials were compared during walking and recovery in the cold. Two kinds of underwear were used: two layers of cotton underwear with two-piece long-sleeved shirt and long-legged trousers (C), two layers of polypropylene underwear with two-piece long-sleeved shirt and long-legged trousers (P). In addition, the subject put on a two-piece ski suit of 100% polyester including 100% polyester padding. Seven adult females served as subjects in this study. The test was done in a climatic chamber at an ambient air temperature of 2 degrees C, a relative humidity of 65% and an air velocity of 0.14 m.s-1. The subject walked on a motor-driven treadmill with a 6 km/h speed for 30 min followed by 60 min recovery. Rectal temperature, skin temperatures, clothing microclimate (temperature, humidity), metabolic heat production and heart rate were measured. Furthermore, subjective ratings on thermal sensation, sweating/shivering sensation, clothing wettedness sensation and skin wettedness sensation for whole body were asked. The major findings are summarized as follows: 1) Mean skin temperature was not significantly different during walking, but it was significantly higher in P than in C during the recovery. 2) The absolute humidity of innermost layer and outermost layer were not significantly different during walking, but it was significantly higher in P than in C during the recovery. 3) Clothing microclimate temperature of innermost was not significantly different during the first half of walking, but it was significantly higher in C than in P during the second half of walking and significantly lower in C than in P during the recovery. Clothing microclimate temperature of outermost was not significantly different during walking, but it was significantly higher in P than in C during the recovery. 4) Metabolic heat production for the last 10 min during recovery tended to be higher in P. 5) The degree of skin wettedness sensation and clothing wettedness sensation for whole body was significantly higher in P during walking and recovery. Thus, it was concluded that two kinds of underwear with different properties to moisture could influence, not only clothing microclimate, but also physiological parameters like skin temperatures and metabolic heat production in the cold differently.
Visco, Giovanni; Plattner, Susanne H; Fortini, Patrizia; Sammartino, Mariapia
2017-06-01
In the last decades, the very fast improvement of the analytical instrumentation has led to the possibility of quickly and easily getting a lot of data; in turn, the need of advanced statistical methods suitable to extract the full information furnished by instruments has increased. Such kind of data treatments is particularly important in any case of continuous monitoring of one or more parameters, so the microclimate monitoring is a typical example for this application. Microclimate control is essential in the conservation of Cultural Heritage (CH), but decisions on optimal conservation parameters cannot base only on existing norms that do not take into account the environment's history. Often CH has survived for many centuries in conditions that must be considered risky but also a stable state (equilibrium) resulting from a long adaptation process during which a more or less heavy damage occurred to the materials. Any successive change of microclimate parameters has interrupted this equilibrium conditions and has induced further damage to material until a new equilibrium is reached; dimension and frequency of changes are proportional to the expected damage. This thermodynamic consideration provides the background for a CH conservation project based on microclimate control and highlights the importance of environmental monitoring for the identification of equilibrium parameters to be maintained. In 2010, we monitored the microclimate of an important historical building in Rome, the Mamertino Carcer, before its opening to visitors. One year later, we repeated the monitoring in the presence of visitors, and here, we present a careful choice of multivariate data treatments adopted for an enough, simple and immediate evaluation of the microclimatic changes; this allows an easier understanding also for persons with not too deep scientific background, such as Superintendents and, in turn, really useful information to provide suggestions for a conservation project. Results evidenced the expected loss of isolation of the site that occurred by opening to visitors; this led to wider excursions of both temperature and relative humidity and, in turn, to a worsening of the conservative conditions. Surely, a monitoring of particulate matter, correlated to air fluxes and, in turn, to microclimate, is of fundamental importance for the conservation of frescoes and will be object of one of our future diagnostic interventions in the site.
2012-01-01
Too often microclimate studies in the field of cultural heritage are published without any or scarce information on sampling design, sensors (type, number, position) and instrument validation. Lacking of this fundamental information does not allow an open discussion in the scientific community. This work aims to be an invitation for a different approach. Three main parameters (temperature, humidity, luminance) were monitored in a selected part of a complex construction by an inexpensive self-assembled system along some horizontal and vertical vectors. All data was then processed and analyse by chemometric methods. Some measurements of oxygen, carbon monoxide and dioxide and pressure were also performed. Correlation of some indoor and outdoor data was shown for temperature and humidity. In case of outdoor changes the indoor environment reacted with a certain delay which is position-dependent and more evident for humidity data. The two observed rooms (Carcer and Tullianum) behave differently and the hypogean one is less influenced by the outdoor environment. Instrument validation before and after the campaign, allows to consider detected variations as significant. The fundamental importance of Sampling Design and of instrument validation before and after the monitoring campaign was enhanced. The choice of two main and two minor vectors allowed detection of different behaviour for the two rooms, also permitting to detect for both rooms a trend towards a spontaneous microclimate necessary for a conservation project. In the next campaign we will focus on the choice of the best sampling frequency to use more sophisticated statistical methods. PMID:22594436
Afanas'eva, R F; Prokopenko, L V; Kiladze, N A; Konstantinov, E I
2009-01-01
The authors demonstrated differences in heat state among workers exposed to heating microclimate during cold and warm seasons. Same external thermal load in cold season induces more humidity loss, lower weighted average skin temperature, higher pulse rate, increased systolic and diastolic blood pressure. With that, heat discomfort was more in cold season, than in warm one, this necessitates decrease of thermal load in cold season vs. the warm one.
LOUNIBOS, L. P.; O'MEARA, G. F.; JULIANO, S. A.; NISHIMURA, N.; ESCHER, R. L.; REISKIND, M. H.; CUTWA, M.; GREENE, K.
2010-01-01
Within 2 yr of the arrival of the invasive container mosquito Aedes albopictus (Skuse), the previously dominant invasive mosquito Aedes aegypti (L.) disappeared from many Florida cemeteries. At some cemeteries, however, Ae. aegypti populations seem stable despite Ae. albopictus invasion. We sought to understand this variation in the outcome (exclusion, coexistence) of this invasion, given that previous experiments show that Ae. albopictus is the superior larval competitor. We tested experimentally the hypothesis that climate-dependent egg survivorship differs between exclusion and coexistence cemeteries and that differences in invasion outcome are associated with microclimate. Viability of eggs oviposited in the laboratory and suspended in vases at six cemeteries was significantly greater for Ae. aegypti than for Ae. albopictus, and greater in 2001 than in 2006. Cemeteries differed significantly in egg survivorship of Ae. albopictus, but not of Ae. aegypti, which is consistent with the hypothesis that Ae. albopictus suffers site-specific, climate-driven egg mortality that mitigates the competitive superiority of larval Ae. albopictus. Principal component (PC) analysis of microclimate records from vases during the experiments yielded three PCs accounting for >96% of the variance in both years of experiments. Multivariate analysis of variance of the three PCs revealed significant microclimate differences among the six cemeteries and between exclusion versus coexistence cemeteries. Stepwise logistic regression of egg survivorship versus microclimate PCs yielded significant fits for both species, and twice as much variance explained for Ae. albopictus as for Ae. aegypti in both years. Higher mortalities in 2006 were associated with high average daily maximum temperatures in vases, with lethal thresholds for both species at ≈40°C. From 1990 to 2007, vase occupancy by Ae. albopictus increased and that by Ae. aegypti decreased, with increasing seasonal precipitation at one well-sampled cemetery. Results support the hypothesis that locally variable climate-driven mortality of Ae. albopictus eggs contributes to patterns of exclusion of, or coexistence with, Ae. aegypti. PMID:20852732
Closed-chamber transepidermal water loss measurement: microclimate, calibration and performance.
Imhof, R E; De Jesus, M E P; Xiao, P; Ciortea, L I; Berg, E P
2009-04-01
The importance of transepidermal water loss (TEWL) as a measure of the skin barrier is well recognized. Currently, the open-chamber method is dominant, but it is increasingly challenged by newer closed-chamber technologies. Whilst there is familiarity with open-chamber characteristics, there is uncertainty about the capabilities of the challengers. The main issues are related to how microclimate affects TEWL measurements. The aim of this paper is to provide a framework for understanding the effects of microclimate on TEWL measurement. Part of the problem is that TEWL measurement is indirect. TEWL is the diffusion of condensed water through the stratum corneum (SC), whereas TEWL methods measure water vapour flux in the air above the SC. This vapour flux depends on (i) the rate of supply of water to the skin surface and (ii) the rate of evaporation of water from the skin surface. Rate (i) is a skin property (TEWL), rate (ii) is a microclimate property. The controlling rate for the combined process is the lower of the above two rates. Therefore, TEWL instruments measure TEWL only when TEWL is the rate-limiting process. Another problem is that SC barrier property and SC hydration are affected by the microclimate adjacent to the skin surface. This is discussed insofar as it affects the measurement of TEWL. The conclusion is that such changes occur on a timescale that is long compared with TEWL measurement times. An important aspect of TEWL measurement is calibration. We present an analysis of the traditional wet-cup method and a new droplet method that is traceable and has been independently verified by a standards laboratory. Finally, we review performance indicators of commercial closed-chamber instruments with reference to open-chamber instruments. The main findings are that TEWL readings correlate well, but there are significant differences in the other aspects of performance.
Hmamouch, Asmae; El Alem, Mahmoud Mohamed; Hakkour, Maryam; Amarir, Fatima; Daghbach, Hassan; Habbari, Khalid; Fellah, Hajiba; Bekhti, Khadija; Sebti, Faiza
2017-02-22
Cutaneous leishmaniasis (CL) is widely distributed in Morocco where its geographical range and incidence are related to environmental factors. This study aimed to examine the impact of several factors on the distribution of CL in Boulemane Province, which is characterized by several microclimates, and to identify the Leishmania species circulating in these areas. Ordinary least squares regression (OLSR) analysis was performed to study the impact of poverty, vulnerability, population density, urbanization and bioclimatic factors on the distribution of CL in this province. Molecular characterization of parasites was performed using a previously described PCR-RFLP method targeting the ITS1 of ribosomal DNA of Leishmania. A total of 1009 cases were declared in Boulemane Province between the years 2000 and 2015 with incidences fluctuating over the years (P = 0.007). Analyzing geographical maps of the study region identified four unique microclimate areas; sub-humid, semi-arid, arid and Saharan. The geographical distribution and molecular identification of species shows that the Saharan microclimate, characterized by the presence of Leishmania major was the most affected (47.78%) followed by semi-arid area where Leishmania tropica was identified in three districts. Among several environmental factors included in the study, poverty had the greatest influence on the spatial extension of the disease in this province. The incidence of CL in Boulemane Province varies between microclimate areas, and environmental factors partly explain this variation. However, the existence of CL in the most affected districts is mainly related to poverty, population movement and human behavior. To our knowledge, this the first study utilizing molecular techniques to confirm L. tropica and L. major as the causative agents of CL in Boulemane Province. Our findings indicate that the spatial and temporal distribution of CL in Boulemane Province is strongly related to poverty and population movement.
Physiological reaction to work in cold microclimate.
Bortkiewicz, Alicja; Gadzicka, Elzbieta; Szymczak, Wiesław; Szyjkowska, Agata; Koszada-Włodarczyk, Wiesława; Makowiec-Dabrowska, Teresa
2006-01-01
In Poland, occupational exposure to cold microclimate is quite common (5.1 workers/1000 occupationally active people). Reports on health effects of this exposure are rather scarce. The aim of the study was to evaluate the physiological reaction in workers occupationally exposed to cold microclimate. Examinations were performed in a group of 102 workers (41 women and 61 men) employed at cold storage units. The mean age in the group was 39.1 +/- 9.9 years and the duration of employment under conditions of cold environment was over 12 years. The study population was divided into four groups, according to microclimate conditions (group I, ambient temperature -26 degrees C; group II, 10-14 degrees C; group III, 18-20 degrees C, control group; and group IV, 0-10 degress C). The workers underwent the following procedures: general medical examinations, cold pressor test, ambulatory blood pressure monitoring, and heart rate variability (HRV) analysis (time- and frequency-domain parameters). The results were adjusted for confounding factors (age, smoking and drinking habits). The analysis of HRV parameters did not reveal any significant differences between the study groups. However, systolic and diastolic blood pressure (BP) in the daytime and at night was significantly higher in group IV compared to group II. Mean heart rate (HR) in the daytime and at night and the BP and HR day/night ratio did not differ between the groups. The analysis of BP by gender revealed that in women, systolic BP during the day and at night was significantly higher in group IV than in group II. In the group of workers with hypertension (18 men and 5 women), men reacted to the cold pressor test either by increased or decreased BP while all the women reacted by the increased BP. Our findings indicated that in workers exposed to cold microclimate, the physiological reaction was dependent on gender and ambient temperature. Women seemed to be more sensitive to cold stress than men. However, this finding must be further investigated.
Landscape-Scale Soil Carbon Inventories by Microclimate Decomposition
NASA Astrophysics Data System (ADS)
Beaudette, D. E.; O'Geen, A. T.
2008-12-01
Estimation of carbon stocks in rangeland and foothill ecosystems is poised to become an important service once legislation regulating greenhouse gas emissions is passed. Trading of carbon credits and greenhouse gas emission/sequestration budgets for vegetated areas is largely dependent on an accurate and scale- dependent inventory of existing conditions. Soil survey presents one possible resource for surface carbon stocks, however these data are usually not mapped at the landscape-scale. Soil-landscape modeling techniques have been successfully used in several instances to predict the spatial variation in soil carbon. Most of these studies have used site exposure (aspect angle) as a categorical proxy for terrain-induced microclimate. Our objective was to model parameters related to soil microclimate (soil temperature and moisture) for the production of detailed maps of soil carbon and organic matter quality (i.e. C:N ratio). We used a solar radiation model and long-term monitoring of soil moisture and temperature to generate several models of soil microclimate. Parameterization of the ESRA (European Solar Radiation Atlas) solar radiation model (clear-sky version) was accomplished with daily estimates of the Linke turbidity factor, using local pyranometer measurements (11 year record). Our estimated daily radiance values correlated well with local weather station data (R2 = 0.965, p < 0.001). This model is included in the popular, open source GRASS GIS. A preliminary study based on 35 sites, spanning two contrasting landform types (and lithology), revealed a statistically significant relationship between annual radiation load and carbon (R2 = 0.75, p < 0.001). A highly significant relationship between C:N ratio and annual radiation load was identified as well (R2 = 0.99, p < 0.001). Solar radiation models are simple to use, and have the potential to refine previous soil-landscape modeling efforts that relied on aspect class or angle. Models linking surface processes with microclimate can be used to directly generate estimates of carbon, or used to down-scale soil survey-based estimates.
Water-use efficiency of a poplar plantation in Northern China
Jie Zhou; Zhiqiang Zhang; Ge sun; Xianrui Fang; Tonggang Zha; Jiquan Chen; Asko Noormets; Junting Guo; Steve McNulty
2014-01-01
The water-use efficiency (WUE) of an ecosystemâdefined as the gross ecosystem production (GEP) divided by the evapotranspiration (ET)âis an important index for understanding the coupling of water and carbon and quantifying waterâcarbon trade-offs in forests. An open-path eddy covariance technique and a microclimate measurement system were deployed to investigate the...
NASA Astrophysics Data System (ADS)
Nicholas, K. A.
2010-12-01
While crop yields are threatened by climate change, the management decisions of growers, including their practices to modify the microclimate experienced by the crop, can partially or even completely offset these damages. However, there have been few evaluations of adaptation on the farm scale, where managers are on the front lines of responding to global change. I will present a framework for classifying potential adaptations based on their temporal and spatial scale, their ease of implementation, and their effectiveness in altering or maintaining crop production. Applying this framework to the winegrowing industry in California, it appears that many strategies suggested in the literature for adaptation will either be of limited effectiveness, likely to be cost-prohibitive, or are not compatible with the current values of growers. However, interviews with and observations of winegrowers reveal that novel adaptations, not widely discussed in the literature, are already being employed, often by individuals in an experimental capacity and without community coordination. For example, in addition to irrigation, water is used to modify the vine microclimate for both heating (frost protection) and evaporative cooling. An analysis of responses to past environmental stresses in the wine industry revealed that growers tended to respond to stresses individually rather than collectively, except for severe, novel pests and diseases. Responses may be reactive or proactive; most proactive strategies have been short-term, in response to imminent stress. Growers tend to rely on their own experience to guide their management decisions, which may offer poor guidance under novel climate regimes. These findings highlight some of the difficulties expected in adapting to global change, as well as areas for strategic investments to enhance agricultural resilience to climate change. In particular, strategies to enhance the potential for effective proactive, collective responses could improve adaptive capacity in the context of climate change.
Micro Climate Simulation in new Town 'Hashtgerd'
NASA Astrophysics Data System (ADS)
Sodoudi, S.; Langer, I.; Cubasch, U.
2012-04-01
One of the objectives of climatological part of project Young Cities 'Developing Energy-Efficient Urban Fabric in the Tehran-Karaj Region' is to simulate the micro climate (with 1m resolution) in 35ha of new town Hashtgerd, which is located 65 km far from mega city Tehran. The Project aims are developing, implementing and evaluating building and planning schemes and technologies which allow to plan and build sustainable, energy-efficient and climate sensible form mass housing settlements in arid and semi-arid regions ("energy-efficient fabric"). Climate sensitive form also means designing and planning for climate change and its related effects for Hashtgerd New Town. By configuration of buildings and open spaces according to solar radiation, wind and vegetation, climate sensitive urban form can create outdoor thermal comfort. To simulate the climate on small spatial scales, the micro climate model Envi-met has been used to simulate the micro climate in 35 ha. The Eulerian model ENVI-met is a micro-scale climate model which gives information about the influence of architecture and buildings as well as vegetation and green area on the micro climate up to 1 m resolution. Envi-met has been run with information from topography, downscaled climate data with neuro-fuzzy method, meteorological measurements, building height and different vegetation variants (low and high number of trees) Through the optimal Urban Design and Planning for the 35ha area the microclimate results shows, that with vegetation the microclimate in streets will be change: • 2 m temperature is decreased by about 2 K • relative humidity increase by about 10 % • soil temperature is decreased by about 3 K • wind speed is decreased by about 60% The style of buildings allows free movement of air, which is of high importance for fresh air supply. The increase of inbuilt areas in 35 ha reduces the heat island effect through cooling caused by vegetation and increase of air humidity which caused by trees evaporation.
Tropical amphibians in shifting thermal landscapes under land-use and climate change.
Nowakowski, A Justin; Watling, James I; Whitfield, Steven M; Todd, Brian D; Kurz, David J; Donnelly, Maureen A
2017-02-01
Land-cover and climate change are both expected to alter species distributions and contribute to future biodiversity loss. However, the combined effects of land-cover and climate change on assemblages, especially at the landscape scale, remain understudied. Lowland tropical amphibians may be particularly susceptible to changes in land cover and climate warming because many species have narrow thermal safety margins resulting from air and body temperatures that are close to their critical thermal maxima (CT max ). We examined how changing thermal landscapes may alter the area of thermally suitable habitat (TSH) for tropical amphibians. We measured microclimates in 6 land-cover types and CT max of 16 frog species in lowland northeastern Costa Rica. We used a biophysical model to estimate core body temperatures of frogs exposed to habitat-specific microclimates while accounting for evaporative cooling and behavior. Thermally suitable habitat area was estimated as the portion of the landscape where species CT max exceeded their habitat-specific maximum body temperatures. We projected changes in TSH area 80 years into the future as a function of land-cover change only, climate change only, and combinations of land-cover and climate-change scenarios representing low and moderate rates of change. Projected decreases in TSH area ranged from 16% under low emissions and reduced forest loss to 30% under moderate emissions and business-as-usual land-cover change. Under a moderate emissions scenario (A1B), climate change alone contributed to 1.7- to 4.5-fold greater losses in TSH area than land-cover change only, suggesting that future decreases in TSH from climate change may outpace structural habitat loss. Forest-restricted species had lower mean CT max than species that occurred in altered habitats, indicating that thermal tolerances will likely shape assemblages in changing thermal landscapes. In the face of ongoing land-cover and climate change, it will be critical to consider changing thermal landscapes in strategies to conserve ectotherm species. © 2016 Society for Conservation Biology.
Outdoor thermal physiology along human pathways: a study using a wearable measurement system
NASA Astrophysics Data System (ADS)
Nakayoshi, Makoto; Kanda, Manabu; Shi, Rui; de Dear, Richard
2015-05-01
An outdoor summer study on thermal physiology along subjects' pathways was conducted in a Japanese city using a unique wearable measurement system that measures all the relevant thermal variables: ambient temperature, humidity, wind speed ( U) and short/long-wave radiation ( S and L), along with some physio-psychological parameters: skin temperature ( T skin), pulse rate, subjective thermal sensation and state of body motion. U, S and L were measured using a globe anemo-radiometer adapted use with pedestrian subjects. The subjects were 26 healthy Japanese adults (14 males, 12 females) ranging from 23 to 74 years in age. Each subject wore a set of instruments that recorded individual microclimate and physiological responses along a designated pedestrian route that traversed various urban textures. The subjects experienced varying thermal environments that could not be represented by fixed-point routine observational data. S fluctuated significantly reflecting the mixture of sunlit/shade distributions within complex urban morphology. U was generally low within urban canyons due to drag by urban obstacles such as buildings but the subjects' movements enhanced convective heat exchanges with the atmosphere, leading to a drop in T skin. The amount of sweating increased as standard effective temperature (SET*) increased. A clear dependence of sweating on gender and body size was found; males sweated more than females; overweight subjects sweated more than standard/underweight subjects. T skin had a linear relationship with SET* and a similarly clear dependence on gender and body size differences. T skin of the higher-sweating groups was lower than that of the lower-sweating groups, reflecting differences in evaporative cooling by perspiration.
Turbine airfoil cooling system with cooling systems using high and low pressure cooling fluids
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marsh, Jan H.; Messmann, Stephen John; Scribner, Carmen Andrew
A turbine airfoil cooling system including a low pressure cooling system and a high pressure cooling system for a turbine airfoil of a gas turbine engine is disclosed. In at least one embodiment, the low pressure cooling system may be an ambient air cooling system, and the high pressure cooling system may be a compressor bleed air cooling system. In at least one embodiment, the compressor bleed air cooling system in communication with a high pressure subsystem that may be a snubber cooling system positioned within a snubber. A delivery system including a movable air supply tube may be usedmore » to separate the low and high pressure cooling subsystems. The delivery system may enable high pressure cooling air to be passed to the snubber cooling system separate from low pressure cooling fluid supplied by the low pressure cooling system to other portions of the turbine airfoil cooling system.« less
Ferrari, Virginia; Dellacassa, Eduardo; Coniberti, Andrés; Disegna, Edgardo
2017-02-01
Aspergillus spp. and Penicillium spp. are the main producers of ochratoxin A (OTA), a mycotoxin responsible for fatal human diseases. Some authorities have established a maximum of 2 μg/L of OTA in wine. Although the incidence and occurrence of OTA in grapes and wine is highly related to climate conditions, as has been extensively documented, there is no conclusive information on the effects of cultivation systems on the presence of OTA. This study focuses on determining the effect of the trellis system, planting density and cordon height on plant microclimate and thus on Aspergillus spp. contamination and OTA production in Tannat wines in Southern Uruguay. Two experiments were conducted during the 2010-2011 growing season: (1) a strip split plot design with five replicates and two cordon heights (CH) (0.5 m and 1.0 m above the soil) were compared in two planting densities (PD) (0.8 and 1.5 m between plants); (2) a randomised complete block design, vertical shoot positioning (VSP) versus Lyra trellis systems were evaluated. The results suggest that, even the macro- and micro-climate growing conditions play an important part in Aspergillus developing on grapes. Agronomical practices also have an undoubted impact on the risk and control of OTA accumulation in wine.
Drone and Worker Brood Microclimates Are Regulated Differentially in Honey Bees, Apis mellifera.
Li, Zhiyong; Huang, Zachary Y; Sharma, Dhruv B; Xue, Yunbo; Wang, Zhi; Ren, Bingzhong
2016-01-01
Honey bee (Apis mellifera) drones and workers show differences in morphology, physiology, and behavior. Because the functions of drones are more related to colony reproduction, and those of workers relate to both survival and reproduction, we hypothesize that the microclimate for worker brood is more precisely regulated than that of drone brood. We assessed temperature and relative humidity (RH) inside honey bee colonies for both drone and worker brood throughout the three-stage development period, using digital HOBO® Data Loggers. The major findings of this study are that 1) both drone and worker castes show the highest temperature for eggs, followed by larvae and then pupae; 2) temperature in drones are maintained at higher precision (smaller variance) in drone eggs and larvae, but at a lower precision in pupae than the corresponding stages of workers; 3) RH regulation showed higher variance in drone than workers across all brood stages; and 4) RH regulation seems largely due to regulation by workers, as the contribution from empty honey combs are much smaller compared to that from adult workers. We conclude that honey bee colonies maintain both temperature and humidity actively; that the microclimate for sealed drone brood is less precisely regulated than worker brood; and that combs with honey contribute very little to the increase of RH in honey bee colonies. These findings increase our understanding of microclimate regulation in honey bees and may have implications for beekeeping practices.
Drone and Worker Brood Microclimates Are Regulated Differentially in Honey Bees, Apis mellifera
Li, Zhiyong; Huang, Zachary Y.; Sharma, Dhruv B.; Xue, Yunbo; Wang, Zhi; Ren, Bingzhong
2016-01-01
Background Honey bee (Apis mellifera) drones and workers show differences in morphology, physiology, and behavior. Because the functions of drones are more related to colony reproduction, and those of workers relate to both survival and reproduction, we hypothesize that the microclimate for worker brood is more precisely regulated than that of drone brood. Methodology/Principal Findings We assessed temperature and relative humidity (RH) inside honey bee colonies for both drone and worker brood throughout the three-stage development period, using digital HOBO® Data Loggers. The major findings of this study are that 1) both drone and worker castes show the highest temperature for eggs, followed by larvae and then pupae; 2) temperature in drones are maintained at higher precision (smaller variance) in drone eggs and larvae, but at a lower precision in pupae than the corresponding stages of workers; 3) RH regulation showed higher variance in drone than workers across all brood stages; and 4) RH regulation seems largely due to regulation by workers, as the contribution from empty honey combs are much smaller compared to that from adult workers. Conclusions/Significance We conclude that honey bee colonies maintain both temperature and humidity actively; that the microclimate for sealed drone brood is less precisely regulated than worker brood; and that combs with honey contribute very little to the increase of RH in honey bee colonies. These findings increase our understanding of microclimate regulation in honey bees and may have implications for beekeeping practices. PMID:26882104
Abd Latif, Zulkiflee; Blackburn, George Alan
2010-03-01
The creation of gaps can strongly influence forest regeneration and habitat diversity within forest ecosystems. However, the precise characteristics of such effects depend, to a large extent, upon the way in which gaps modify microclimate and soil water content. Hence, the aim of this study was to understand the effects of gap creation and variations in gap size on forest microclimate and soil water content. The study site, in North West England, was a mixed temperate broadleaved deciduous forest dominated by mature sessile oak (Quercus petraea), beech (Fagus sylvatica) and ash (Fraxinus excelsior) with some representatives of sycamore (Acer pseudoplatanus). Solar radiation (I), air temperature (T(A)), soil temperature (T(S)), relative humidity (h), wind speed (v) and soil water content (Psi) were measured at four natural treefall gaps created after a severe storm in 2006 and adjacent sub-canopy sites. I, T(A), T(S), and Psi increased significantly with gap size; h was consistently lower in gaps than the sub-canopy but did not vary with gap size, while the variability of v could not be explained by the presence or size of gaps. There were systematic diurnal patterns in all microclimate variables in response to gaps, but no such patterns existed for Psi. These results further our understanding of the abiotic and consequent biotic responses to gaps in broadleaved deciduous forests created by natural treefalls, and provide a useful basis for evaluating the implications of forest management practices.
NASA Astrophysics Data System (ADS)
Coughlan, Neil E.; Kelly, Tom C.; Davenport, John; Jansen, Marcel A. K.
2015-05-01
Birds as carriers of propagules are major agents in the dispersal of plants, animals, fungi and microbes. However, there is a lack of empirical data in relation to bird-mediated, epizoochorous dispersal. The microclimate found within the plumage likely plays a pivotal role in survival during flight conditions. To investigate the potential of epizoochory, we have analysed the microclimatic conditions within the plumage of mallard ducks (Anas platyrhynchos). Under similar ambient conditions of humidity and temperature, a sample of mallards showed a consistent microclimatic regime with variation across the body surface. The highest (mean) temperature and specific humidity occurred between feathers of the postpatagium. The lowest humidity was found between feathers of the centre back and the lowest temperature in the crissum. Observed differences in plumage depth and density, and distance from the skin, are all likely to be determining factors of microclimate condition. Specific humidity found within the plumage was on average 1.8-3.5 times greater than ambient specific humidity. Thus, the plumage can supply a microclimate buffered from that of the exterior environment. Extrapolating survival data for Lemna minor desiccation at various temperature and humidity levels to the measured plumage microclimatic conditions of living birds, survival for up to 6 h can be anticipated, especially in crissum, crural and breast plumage. The results are discussed in the context of potential long distance epizoochorous dispersal by A. platyrhynchos and similar species.
Hetem, Robyn S; Maloney, Shane K; Fuller, Andrea; Meyer, Leith C R; Mitchell, Duncan
2007-06-01
Behavioural thermoregulation is an animal's primary defence against changes in the thermal environment. We aimed to validate a remote technique to quantify the thermal environment behaviourally selected by free-ranging ungulates. First, we demonstrated that the temperature of miniature, 30 mm diameter, black globes (miniglobes) could be converted to standard, 150 mm diameter, black globe temperatures. Miniglobe temperature sensors subsequently were fitted to collars on three free-ranging ungulates, namely blue wildebeest (Connochaetes taurinus), impala (Aepyceros melampus) and horse (Equus caballus). Behavioural observations were reflected in animal miniglobe temperatures which differed from those recorded by an identical miniglobe on a nearby exposed weather station. The wildebeest often selected sites protected from the wind, whereas the impala and the horse sheltered from the sun. Nested analysis of variances revealed that the impala and horse selected significantly less variable environments than those recorded at the weather station (P<0.001) over a 20-min time interval, whereas, the microclimates selected by wildebeest tended to be more variable (P=0.08). Correlation of animal miniglobe against weather station miniglobe temperature resulted in regression slopes significantly less than one (P<0.001) for all species studied, implying that, overall, the animals selected cooler microclimates at high environmental heat loads and/or warmer microclimates at low environmental heat loads. We, therefore, have developed an ambulatory device, which can be attached to free-ranging animals, to remotely quantify thermoregulatory behaviour and selected microclimates. (c) 2007 Wiley-Liss, Inc.
NASA Astrophysics Data System (ADS)
Korbut, Vadim; Voznyak, Orest; Sukholova, Iryna; Myroniuk, Khrystyna
2017-12-01
The abstract is to The article is devoted to the decision of actual task of air distribution efficiency increasing with the help of swirl and spread air jets to provide normative parameters of air in the production apartments. The mathematical model of air supply with swirl and spread air jets in that type of apartments is improved. It is shown that for reachin of air distribution maximal efficiency it is necessary to supply air by air jets, that intensively extinct before entering into a working area. Simulation of air flow performed with the help of CFD FLUENT (Ansys FLUENT). Calculations of the equation by using one-parameter model of turbulence Spalart-Allmaras are presented. The graphical and the analytical dependences on the basis of the conducted experimental researches, which can be used in subsequent engineering calculations, are shown out. Dynamic parameters of air flow that is created due to swirl and spread air jets at their leakage at variable regime and creation of dynamic microclimate in a room has been determined. Results of experimental investigations of air supply into the room by air distribution device which creates swirl air jets for creation more intensive turbulization air flow in the room are presented. Obtained results of these investigations give possibility to realize engineer calculations of air distribution with swirl air jets. The results of theoretical researches of favourable influence of dynamic microclimate to the man are presented. When using dynamic microclimate, it's possible to decrease conditioning and ventilation system expenses. Human organism reacts favourably on short lasting deviations from the rationed parameters of air environment.
Evans, Michelle V.; McClanahan, Taylor D.; Miazgowicz, Kerri L.; Tesla, Blanka
2017-01-01
Most statistical and mechanistic models used to predict mosquito-borne disease transmission incorporate climate drivers of disease transmission by utilizing environmental data collected at geographic scales that are potentially coarser than what mosquito populations may actually experience. Temperature and relative humidity can vary greatly between indoor and outdoor environments, and can be influenced strongly by variation in landscape features. In the Aedes albopictus system, we conducted a proof-of-concept study in the vicinity of the University of Georgia to explore the effects of fine-scale microclimate variation on mosquito life history and vectorial capacity (VC). We placed Ae. albopictus larvae in artificial pots distributed across three replicate sites within three different land uses–urban, suburban, and rural, which were characterized by high, intermediate, and low proportions of impervious surfaces. Data loggers were placed into each larval environment and in nearby vegetation to record daily variation in water and ambient temperature and relative humidity. The number of adults emerging from each pot and their body size and sex were recorded daily. We found mosquito microclimate to significantly vary across the season as well as with land use. Urban sites were in general warmer and less humid than suburban and rural sites, translating into decreased larval survival, smaller body sizes, and lower per capita growth rates of mosquitoes on urban sites. Dengue transmission potential was predicted to be higher in the summer than the fall. Additionally, the effects of land use on dengue transmission potential varied by season. Warm summers resulted in a higher predicted VC on the cooler, rural sites, while warmer, urban sites had a higher predicted VC during the cooler fall season. PMID:28558030
Murdock, Courtney C; Evans, Michelle V; McClanahan, Taylor D; Miazgowicz, Kerri L; Tesla, Blanka
2017-05-01
Most statistical and mechanistic models used to predict mosquito-borne disease transmission incorporate climate drivers of disease transmission by utilizing environmental data collected at geographic scales that are potentially coarser than what mosquito populations may actually experience. Temperature and relative humidity can vary greatly between indoor and outdoor environments, and can be influenced strongly by variation in landscape features. In the Aedes albopictus system, we conducted a proof-of-concept study in the vicinity of the University of Georgia to explore the effects of fine-scale microclimate variation on mosquito life history and vectorial capacity (VC). We placed Ae. albopictus larvae in artificial pots distributed across three replicate sites within three different land uses-urban, suburban, and rural, which were characterized by high, intermediate, and low proportions of impervious surfaces. Data loggers were placed into each larval environment and in nearby vegetation to record daily variation in water and ambient temperature and relative humidity. The number of adults emerging from each pot and their body size and sex were recorded daily. We found mosquito microclimate to significantly vary across the season as well as with land use. Urban sites were in general warmer and less humid than suburban and rural sites, translating into decreased larval survival, smaller body sizes, and lower per capita growth rates of mosquitoes on urban sites. Dengue transmission potential was predicted to be higher in the summer than the fall. Additionally, the effects of land use on dengue transmission potential varied by season. Warm summers resulted in a higher predicted VC on the cooler, rural sites, while warmer, urban sites had a higher predicted VC during the cooler fall season.
NASA Astrophysics Data System (ADS)
Moody, M.; Bailey, B.; Stoll, R., II
2017-12-01
Understanding how changes in the microclimate near individual plants affects the surface energy budget is integral to modeling land-atmosphere interactions and a wide range of near surface atmospheric boundary layer phenomena. In urban areas, the complex geometry of the urban canopy layer results in large spatial deviations of turbulent fluxes further complicating the development of models. Accurately accounting for this heterogeneity in order to model urban energy and water use requires a sub-plant level understanding of microclimate variables. We present analysis of new experimental field data taken in and around two Blue Spruce (Picea pungens) trees at the University of Utah in 2015. The test sites were chosen in order study the effects of heterogeneity in an urban environment. An array of sensors were placed in and around the conifers to quantify transport in the soil-plant-atmosphere continuum: radiative fluxes, temperature, sap fluxes, etc. A spatial array of LEMS (Local Energy Measurement Systems) were deployed to obtain pressure, surrounding air temperature and relative humidity. These quantities are used to calculate the radiative and turbulent fluxes. Relying on measurements alone is insufficient to capture the complexity of microclimate distribution as one reaches sub-plant scales. A spatially-explicit radiation and energy balance model previously developed for deciduous trees was extended to include conifers. The model discretizes the tree into isothermal sub-volumes on which energy balances are performed and utilizes incoming radiation as the primary forcing input. The radiative transfer component of the model yields good agreement between measured and modeled upward longwave and shortwave radiative fluxes. Ultimately, the model was validated through an examination of the full energy budget including radiative and turbulent fluxes through isolated Picea pungens in an urban environment.
Automated soil gas monitoring chamber
Edwards, Nelson T.; Riggs, Jeffery S.
2003-07-29
A chamber for trapping soil gases as they evolve from the soil without disturbance to the soil and to the natural microclimate within the chamber has been invented. The chamber opens between measurements and therefore does not alter the metabolic processes that influence soil gas efflux rates. A multiple chamber system provides for repetitive multi-point sampling, undisturbed metabolic soil processes between sampling, and an essentially airtight sampling chamber operating at ambient pressure.
Modelled and field measurements of biogenic hydrocarbon emissions from a Canadian deciduous forest
NASA Astrophysics Data System (ADS)
Fuentes, J. D.; Wang, D.; Den Hartog, G.; Neumann, H. H.; Dann, T. F.; Puckett, K. J.
The Biogenic Emission Inventory System (BEIS) used by the United States Environmental Protection Agency (Lamb et al., 1993, Atmospheric Environment21, 1695-1705; Pierce and Waldruff, 1991, J. Air Waste Man. Ass.41, 937-941) was tested for its ability to provide realistic microclimate descriptions within a deciduous forest in Canada. The microclimate description within plant canopies is required because isoprene emission rates from plants are strongly influenced by foliage temperature and photosynthetically active radiation impinging on leaves while monoterpene emissions depend primarily on leaf temperature. Model microclimate results combined with plant emission rates and local biomass distribution were used to derive isoprene and α-pinene emissions from the deciduous forest canopy. In addition, modelled isoprene emission estimates were compared to measured emission rates at the leaf level. The current model formulation provides realistic microclimatic conditions for the forest crown where modelled and measured air and foliage temperature are within 3°C. However, the model provides inadequate microclimate characterizations in the lower canopy where estimated and measured foliage temperatures differ by as much as 10°C. This poor agreement may be partly due to improper model characterization of relative humidity and ambient temperature within the canopy. These uncertainties in estimated foliage temperature can lead to underestimates of hydrocarbon emission estimates of two-fold. Moreover, the model overestimates hydrocarbon emissions during the early part of the growing season and underestimates emissions during the middle and latter part of the growing season. These emission uncertainties arise because of the assumed constant biomass distribution of the forest and constant hydrocarbon emission rates throughout the season. The BEIS model, which is presently used in Canada to estimate inventories of hydrocarbon emissions from vegetation, underestimates emission rates by at least two-fold compared to emissions derived from field measurements. The isoprene emission algorithm proposed by Guenther et al. (1993), applied at the leaf level, provides relatively good agreement compared to measurements. Field measurements indicate that isoprene emissions change with leaf ontogeny and differ amongst tree species. Emission rates defined as function of foliage development stage and plant species need to be introduced in the hydrocarbon emission algorithms. Extensive model evaluation and more hydrocarbon emission measurement;: from different plant species are required to fully assess the appropriateness of this emission calculation approach for Canadian forests.
NASA Astrophysics Data System (ADS)
Pérez Lancellotti, Gino; Ziede Bize, Marcela
2017-10-01
This article proposes to make a comparative bioclimatic analysis from 1990 to 2014 of the main square of Antofagasta, a coastal desert city in Chile, which was remodelled in 1995, and shows how the redesigning of green areas affects the microclimatic conditions and thermal comfort of the urban space. Ex ante measurements dating 1990 were compared with ex post results from 2014. Data were obtained in both cases in the month of September at different times of a day and in different climate conditions. The variables studied were: land surface temperature, humidity, wind speed, amount of light and square use frequency inside the square and in surrounding streets. The temperatures are not statistically different during the years 1990 and 2014 for the city of Antofagasta. The main layout of the square has not changed, and inside the square it is similar for both periods, but new species were introduced and bigger trees with shadow projection were cut down. The square had a micro-climate role in 2014 as well as in 1990. The highest frequency zone with an important surface lost it is comfort thermic condition with an increase of 1°C. Other smaller zones with less relevance for users gained in cooling with a 0.5°C reduction. The new design has been detrimental to the intensity of its micro climatic regulatory function affecting the thermic comfort of the square’s internal spaces, especially those formerly protected by shadow, which mitigate a high solar radiation. The study results suggest that bio-climatic analysis of public open spaces is a key component for the design of future projects as a heat mitigating tool in the context of climate change. Research question is: How does the redesign of the square impact a cool urban island and the thermic comfort of users? Significant differences between data in situ collected in 1990 and 2014. Thermal comfort was negatively affected by the redesign in the square. The square is still a cool island but with less strength.
2012-01-01
Background This paper discusses results obtained in the second monitoring campaign of the Carcer Tullianum, a particular hypogeum environment located in the historical centre of Rome (Italy). In the first paper we stressed the need to apply chemometric tools to this kind of studies in order to obtain full and significant information; really information on sampling design, sensors (type, number, position) and instrument validation seems to be not easy to find in literature for researches dealing with monitoring of indoor environments. Also in this case three main parameters (temperature, humidity, illuminance) were monitored in the complex construction by an inexpensive self-assembled system along some horizontal and vertical vectors together with some measurements of oxygen, carbon dioxide and barometric pressure. With respect to the first campaign, we used a higher number of sensors to cover a new excavated zone; for the same reason, as well as to take into account the presence of visitors, a different experimental design was adopted. Results Different data treatments were applied to data coming from all the used sensors. A good view of the microclimate was obtained that also resulted coherent with the different position of the three rooms constituting the monitored site (Carcer, Tullianum, Convent). Classical time plots resulted useful to evidence the correlation of the main monitored parameters (T, RH% and illuminance) with macroclimate, as well as their delay in following macroclimate. Box-Whisker and Gain-Loss graphs evidenced at the best the microclimate differences between the three rooms; an almost hypogean microclimate was evidenced for the lower room (Tullianum) where humidity values range between 90 and 100% while lower values, but anyway higher than the external, and spread more widely were measured passing to Convent and Carcer with minimum values around 50% for the last. A scarce or very scarce correlation with macroclimate was evidenced for all the three main measured parameters. Lighting results mainly dependent on artificial light and only in few cases, but unfortunately in the most precious zone, illuminance exceeds values suggested by Normative. Conclusions Box-Whisker and Gain-Loss graphs allowed us to have the best view of the microclimate for all the monitored rooms. The influence of lighting by lamps on the other monitored parameters resulted overlapped and clearly topped the solar one. The worst situation was found in the Carcer, where the presence of the main chandelier worsens the state of the frescoed walls, already subjected to wide changes in temperature and humidity. Also the lighthouse located above the Convent provokes lighting exceeding values suggested by Normative while, as expected, LEDs resulted as suitable source of light from a conservation point of view. Susanne Heidi Plattner, Patrizia Fortini and Maria Pia Sammartino contributed equally to this work PMID:22989166
Yoshimura, Mine; Nakagami, Gojiro; Iizaka, Shinji; Yoshida, Mikako; Uehata, Yoko; Kohno, Michihiro; Kasuya, Yusuke; Mae, Tomoko; Yamasaki, Takashi; Sanada, Hiromi
2015-01-01
Preventing pressure ulcers is important in patients undergoing procedures in the park-bench position. We hypothesized that the microclimate around the skin is a significant risk factor for developing pressure ulcers. This research continuously assessed factors of the microclimate in terms of skin temperature and perspiration as well as the interface pressure in order to determine whether the microclimate is an independent risk factor for the development of park-bench position-related pressure ulcers (PBP-PUs). A prospective observational study was conducted among patients undergoing elective surgery in the park-bench position at a general hospital in the metropolitan area of Japan between April and November 2014. Factors of the microclimate, including skin temperature and perspiration, in addition to the interface pressure were continuously measured throughout surgery. Twenty-nine patients were analyzed (mean age 44.4 ± 13.2 years, male 44.8%). Of these 29 patients, seven (24.1%) developed Category I PBP-PUs. The change in skin temperature from baseline to the end of surgery (2.7 ± 0.3 °C vs. 1.9 ± 0.8 °C) and the average peak pressure (119.1 ± 36.8 mmHg vs. 94.5 ± 23.1 mmHg) were significantly higher in the patients with PBP-PUs than in those without PBP-PUs. There were no significant differences in the amount of perspiration between the two groups. A hierarchical logistic regression analysis showed that the change in skin temperature was significantly related to the development of PBP-PUs (unit = 0.1 °C: odds ratio 1.44, 95% confidential interval 1.09-2.33) when adjusted for the average peak pressure and length of surgery. Our results suggest that a change in skin temperature toward a higher value is an independent risk factor for the development of PBP-PUs. Proper intraoperative management of skin temperature may therefore be a promising candidate as a preventive method against PBP-PU development. © 2015 by the Wound Healing Society.
NASA Astrophysics Data System (ADS)
Campbell, E. E.; Dorich, C.; Contosta, A.; Varner, R. K.
2017-12-01
In livestock agroecosystems, the combined contributions of enteric fermentation, manure management, and livestock grazing and/or feed production play an important role in agroecosystem carbon (C) storage and GHG losses, with complete livestock system models acting as important tools to evaluate the full impacts of these complex systems. The Manure-DeNitrification-DeComposition (DNDC) model is one such example, simulating impacts on C and nitrogen cycling, estimating methane, carbon dioxide, nitrous oxide, and ammonium dynamics in fields, manure storage, and enteric emissions. This allows the evaluation of differences in GHG and soil C impacts between conventional and organic dairy production systems, which differ in their use of grazed pasture versus confined feeding operations. However, Manure-DNDC has received limited testing in representing variations in grazed pasture management (i.e. intensive rotational grazing versus standard grazing practices). Using a set of forage biomass, soil C, and GHG emissions data collected at four sites across New England, we parameterized and validated Manure-DNDC estimations of GHG emissions and soil C in grazed versus un-grazed systems. Soil observations from these sites showed little effect from grazing practices, but larger soil carbon differences between farms. This may be due to spatial variation in SOC, making it difficult to measure and model, or due to controls of edaphic properties that make management moot. However, to further address these questions, model development will be needed to improve Manure-DNDC simulation of rotational grazing, as high stocking density grazing over short periods resulted in forage not re-growing sufficiently within the model. Furthermore, model simulations did not account for variation in interactions between livestock and soil given variability in field microclimates, perhaps requiring simulations that divide a single field into multiple paddocks to move towards more accurate evaluation of grazing management used in dairy operations in cool season pastures.
Separating temperature from other factors in phenological measurements
NASA Astrophysics Data System (ADS)
Schwartz, Mark D.; Hanes, Jonathan M.; Liang, Liang
2014-09-01
Phenological observations offer a simple and effective way to measure climate change effects on the biosphere. While some species in northern mixed forests show a highly sensitive site preference to microenvironmental differences (i.e., the species is present in certain areas and absent in others), others with a more plastic environmental response (e.g., Acer saccharum, sugar maple) allow provisional separation of the universal "background" phenological variation caused by in situ (possibly biological/genetic) variation from the microclimatic gradients in air temperature. Moran's I tests for spatial autocorrelation among the phenological data showed significant ( α ≤ 0.05) clustering across the study area, but random patterns within the microclimates themselves, with isolated exceptions. In other words, the presence of microclimates throughout the study area generally results in spatial autocorrelation because they impact the overall phenological development of sugar maple trees. However, within each microclimate (where temperature conditions are relatively uniform) there is little or no spatial autocorrelation because phenological differences are due largely to randomly distributed in situ factors. The phenological responses from 2008 and 2009 for two sugar maple phenological stages showed the relationship between air temperature degree-hour departure and phenological change ranged from 0.5 to 1.2 days earlier for each additional 100 degree-hours. Further, the standard deviations of phenological event dates within individual microclimates (for specific events and years) ranged from 2.6 to 3.8 days. Thus, that range of days is inferred to be the "background" phenological variation caused by factors other than air temperature variations, such as genetic differences between individuals.
Groff, Luke A.; Calhoun, Aram J.K.; Loftin, Cynthia S.
2016-01-01
Poikilothermic species, such as amphibians, endure harsh winter conditions via freeze-tolerance or freeze-avoidance strategies. Freeze-tolerance requires a suite of complex, physiological mechanisms (e.g., cryoprotectant synthesis); however, behavioral strategies (e.g., hibernal habitat selection) may be used to regulate hibernaculum temperatures and promote overwintering survival. We investigated the hibernal ecology of the freeze-tolerant Wood Frog (Lithobates sylvaticus) in north-central Maine. Our objectives were to characterize the species hibernaculum microclimate (temperature, relative humidity), evaluate hibernal habitat selection, and describe the spatial arrangement of breeding, post-breeding, and hibernal habitats. We monitored 15 frogs during two winters (2011/12: N = 10; 2012/13: N = 5), measured hibernal habitat features at micro (2 m) and macro (10 m) spatial scales, and recorded microclimate hourly in three strata (hibernaculum, leaf litter, ambient air). We compared these data to that of 57 random locations with logistic regression models, Akaike Information Criterion, and Kolmogorov–Smirnov tests. Hibernaculum microclimate was significantly different and less variable than leaf litter, ambient air, and random location microclimate. Model averaging indicated that canopy cover (−), leaf litter depth (+), and number of logs and stumps (+; microhabitat only) were important predictors of Wood Frog hibernal habitat. These habitat features likely act to insulate hibernating frogs from extreme and variable air temperatures. For example, decreased canopy cover facilitates increased snowpack depth and earlier snowpack accumulation and melt. Altered winter temperature and precipitation patterns attributable to climate change may reduce snowpack insulation, facilitate greater temperature variation in the underlying hibernacula, and potentially compromise Wood Frog winter survival.
The effect of landscape complexity and microclimate on the thermal tolerance of a pest insect.
Alford, Lucy; Tougeron, Kévin; Pierre, Jean-Sébastien; Burel, Françoise; van Baaren, Joan
2017-03-21
Landscape changes are known to exacerbate the impacts of climate change. As such, understanding the combined effect of climate and landscape on agroecosystems is vital if we are to maintain the function of agroecosystems. This study aimed to elucidate the effects of agricultural landscape complexity on the microclimate and thermal tolerance of an aphid pest to better understand how landscape and climate may interact to affect the thermal tolerance of pest species within the context of global climate change. Meteorological data were measured at the landscape level, and cereal aphids (Sitobion avenae, Metopolophium dirhodum and Rhopalosiphum padi) sampled, from contrasting landscapes (simple and complex) in winter 2013/2014 and spring 2014 in cereal fields of Brittany, France. Aphids were returned to the laboratory and the effect of landscape of origin on aphid cold tolerance (as determined by CT min ) was investigated. Results revealed that local landscape complexity significantly affected microclimate, with simple homogenous landscapes being on average warmer, but with greater temperature variation. Landscape complexity was shown to impact aphid cold tolerance, with aphids from complex landscapes being more cold tolerant than those from simple landscapes in both winter and spring, but with differences among species. This study highlights that future changes to land use could have implications for the thermal tolerance and adaptability of insects. Furthermore, not all insect species respond in a similar way to microhabitat and microclimate, which could disrupt important predator-prey relationships and the ecosystem service they provide. © 2017 Institute of Zoology, Chinese Academy of Sciences.
Bogerd, Cornelis Peter; Rechsteiner, Ivo; Wüst, Benno; Rossi, René M; Brühwiler, Paul A
2011-06-01
The goal of the present study was to investigate physiological effects, mainly at the level of the foot, of two sock fabrics with distinct moisture properties. Twelve participants wore two different socks, one on each foot. The following two sock types were used: PP: 99.6% polypropylene and 0.4% elastane and BLEND: 50% Merino wool, 33% polypropylene, and 17% polyamide. The participants walked three times on a treadmill at 5 km h(-1), with no gradient for the first and third phase and a 10% upward inclination for the second walking phase. The microclimate temperature between the boot and foot was measured during walking. Preceding and following the walking phases, additional measurements were carried out at the level of the foot, i.e. skin temperature and skin hydration on three locations and skin friction between the posterior surface of the calcaneus and a glass plate. In addition, the moisture absorption of boots and socks was determined. Differences between the sock fabrics were found for weight gain and microclimate temperature: (i) PP tended to hold less water compared to BLEND, (ii) the boot's microclimate temperature resulted in larger values for BLEND measured at the dorsal surface at the level of the third metatarsal, and (iii) warmer microclimates of the boot were measured for PP compared to BLEND at the distal anterior end of the tibia. The established differences in moisture behavior of both socks did not result in detectable differences in parameters measured on the skin of the foot.
Johns, R C; Boone, J; Leggo, J J; Smith, S; Carleton, D; Quiring, D T
2012-06-01
Herbivorous insects are often exposed to broad temporal and spatial variations in microclimate conditions within their host plants and have adapted a variety of behaviors, such as avoidance or basking, to either offset or benefit from such variation. Field experiments were carried out to investigate the influence of daily and intratree variations in microclimate on the behaviors (feeding, resting, dispersal, and hiding) and associated performance of late-instar larvae of the yellowheaded spruce sawfly, Pikonema alaskensis (Rohwer) (Hymenoptera: Tenthredinidae) within crowns of 1.25-1.5 m tall black spruce (Picea mariana [Miller] Britton Sterns Poggenburg); late instars feed on developing shoots of young spruce and are often exposed to microclimatic extremes with unknown effects on performance. Larvae fed diurnally from just after dawn (0800 h) until dusk (2000 h) and rested throughout the night, with brief periods of dispersal occurring in the morning and evening. Neither larval behavior nor abiotic conditions differed significantly between the upper and lower crowns of trees. Temperature, humidity, and solar insolation all explained >90% of variation in feeding; however, sunrise and sunset were the most likely cues influencing diurnal behavior. Most larvae (94%) fed on the bottom, shaded side of shoots, and field experiments indicated that this behavior is adaptive with respect to microclimate, probably reducing hygrothermal stress. Thus, behavioral adaptations by P. alaskensis to daily and within-shoot microclimatic variation may reduce the risk of hygrothermal stress during dispersal or feeding, while still allowing larvae to feed on the preferred and highly nutritious upper crown foliage of young spruce.
Fragmentation impairs the microclimate buffering effect of tropical forests.
Ewers, Robert M; Banks-Leite, Cristina
2013-01-01
Tropical forest species are among the most sensitive to changing climatic conditions, and the forest they inhabit helps to buffer their microclimate from the variable climatic conditions outside the forest. However, habitat fragmentation and edge effects exposes vegetation to outside microclimatic conditions, thereby reducing the ability of the forest to buffer climatic variation. In this paper, we ask what proportion of forest in a fragmented ecosystem is impacted by altered microclimate conditions driven by edge effects, and extrapolate these results to the whole Atlantic Forest biome, one of the most disturbed biodiversity hotspots. To address these questions, we collected above and below ground temperature for a full year using temperature sensors placed in forest fragments of different sizes, and at different distances from the forest edge. In the Atlantic forests of Brazil, we found that the buffering effect of forests reduced maximum outside temperatures by one third or more at ground level within a forest, with the buffering effect being stronger below-ground than one metre above-ground. The temperature buffering effect of forests was, however, reduced near forest edges with the edge effect extending up to 20 m inside the forest. The heavily fragmented nature of the Brazilian Atlantic forest means that 12% of the remaining biome experiences altered microclimate conditions. Our results add further information about the extent of edge effects in the Atlantic Forest, and we suggest that maintaining a low perimeter-to-area ratio may be a judicious method for minimizing the amount of forest area that experiences altered microclimatic conditions in this ecosystem.
Fragmentation Impairs the Microclimate Buffering Effect of Tropical Forests
Ewers, Robert M.; Banks-Leite, Cristina
2013-01-01
Background Tropical forest species are among the most sensitive to changing climatic conditions, and the forest they inhabit helps to buffer their microclimate from the variable climatic conditions outside the forest. However, habitat fragmentation and edge effects exposes vegetation to outside microclimatic conditions, thereby reducing the ability of the forest to buffer climatic variation. In this paper, we ask what proportion of forest in a fragmented ecosystem is impacted by altered microclimate conditions driven by edge effects, and extrapolate these results to the whole Atlantic Forest biome, one of the most disturbed biodiversity hotspots. To address these questions, we collected above and below ground temperature for a full year using temperature sensors placed in forest fragments of different sizes, and at different distances from the forest edge. Principal Findings In the Atlantic forests of Brazil, we found that the buffering effect of forests reduced maximum outside temperatures by one third or more at ground level within a forest, with the buffering effect being stronger below-ground than one metre above-ground. The temperature buffering effect of forests was, however, reduced near forest edges with the edge effect extending up to 20 m inside the forest. The heavily fragmented nature of the Brazilian Atlantic forest means that 12% of the remaining biome experiences altered microclimate conditions. Conclusions Our results add further information about the extent of edge effects in the Atlantic Forest, and we suggest that maintaining a low perimeter-to-area ratio may be a judicious method for minimizing the amount of forest area that experiences altered microclimatic conditions in this ecosystem. PMID:23483976
Valero, Miguel Ángel; Merello, Paloma; Navajas, Ángel Fernández; García-Diego, Fernando-Juan
2014-01-01
The Noheda archaeological site is unique and exceptional for its size, and the quality and conservation condition of the Roman mosaic pavement covering its urban pars. In 2008 a tent was installed as protection from rain and sun. Being of interest to characterise the microclimate of the remains, six probes with relative humidity and temperature sensors were installed in 2013 for this purpose. Microclimate monitoring allowed us to check relative humidity differences resulting from the groundwater level, as well as inner sensors reaching maximum temperatures higher than the outdoors ones as a consequence of the non-ventilated tent covering the archaeological site. Microclimatic conditions in the archaeological site were deemed detrimental for the conservation of the mosaics. Thus, in summer 2013, expanded clay and geotextile were installed over the mosaics as a corrective action. The outcomes of this study have proven the effectiveness of this solution to control temperature and relative humidity, helping to configure a more stable microclimate suitable for preservation of the mosaic. PMID:24445414
Valero, Miguel Ángel; Merello, Paloma; Navajas, Ángel Fernández; García-Diego, Fernando-Juan
2014-01-17
The Noheda archaeological site is unique and exceptional for its size, and the quality and conservation condition of the Roman mosaic pavement covering its urban pars. In 2008 a tent was installed as protection from rain and sun. Being of interest to characterise the microclimate of the remains, six probes with relative humidity and temperature sensors were installed in 2013 for this purpose. Microclimate monitoring allowed us to check relative humidity differences resulting from the groundwater level, as well as inner sensors reaching maximum temperatures higher than the outdoors ones as a consequence of the non-ventilated tent covering the archaeological site. Microclimatic conditions in the archaeological site were deemed detrimental for the conservation of the mosaics. Thus, in summer 2013, expanded clay and geotextile were installed over the mosaics as a corrective action. The outcomes of this study have proven the effectiveness of this solution to control temperature and relative humidity, helping to configure a more stable microclimate suitable for preservation of the mosaic.
Effectiveness-weighted control method for a cooling system
Campbell, Levi A.; Chu, Richard C.; David, Milnes P.; Ellsworth Jr., Michael J.; Iyengar, Madhusudan K.; Schmidt, Roger R.; Simons, Robert E.
2015-12-15
Energy efficient control of cooling system cooling of an electronic system is provided based, in part, on weighted cooling effectiveness of the components. The control includes automatically determining speed control settings for multiple adjustable cooling components of the cooling system. The automatically determining is based, at least in part, on weighted cooling effectiveness of the components of the cooling system, and the determining operates to limit power consumption of at least the cooling system, while ensuring that a target temperature associated with at least one of the cooling system or the electronic system is within a desired range by provisioning, based on the weighted cooling effectiveness, a desired target temperature change among the multiple adjustable cooling components of the cooling system. The provisioning includes provisioning applied power to the multiple adjustable cooling components via, at least in part, the determined control settings.
Effectiveness-weighted control of cooling system components
Campbell, Levi A.; Chu, Richard C.; David, Milnes P.; Ellsworth Jr., Michael J.; Iyengar, Madhusudan K.; Schmidt, Roger R.; Simmons, Robert E.
2015-12-22
Energy efficient control of cooling system cooling of an electronic system is provided based, in part, on weighted cooling effectiveness of the components. The control includes automatically determining speed control settings for multiple adjustable cooling components of the cooling system. The automatically determining is based, at least in part, on weighted cooling effectiveness of the components of the cooling system, and the determining operates to limit power consumption of at least the cooling system, while ensuring that a target temperature associated with at least one of the cooling system or the electronic system is within a desired range by provisioning, based on the weighted cooling effectiveness, a desired target temperature change among the multiple adjustable cooling components of the cooling system. The provisioning includes provisioning applied power to the multiple adjustable cooling components via, at least in part, the determined control settings.
Sidorchuk, N V; Rozhnov, V V
2008-01-01
Data on the microclimate (air temperature and humidity) within an unoccupied badger sett in the Darwin Reserve (the Vologda Region) between September 2005 and May 2006 have been analyzed in relation to changes in the temperature and humidity of the ground air layer and soil. A positive correlation has been revealed between the temperature regime of the soil and air temperature within the sett. After the establishment of snow cover, air and soil temperatures within the sett vary slightly and barely depend on ambient air temperature.
NASA Technical Reports Server (NTRS)
Zimmermann, R.; McDonald, K.; Way, J.; Oren, R.
1994-01-01
Tree canopy microclimate, xylem water flux and xylem dielectric constant have been monitored in situ since June 1993 in two adjacent natural forest stands in central Alaska. The deciduous stand represents a mature balsam poplar site on the Tanana River floodplain, while the coniferous stand consists of mature white spruce with some black spruce mixed in. During solstice in June and later in summer, diurnal changes of xylem water potential were measured to investigate the occurrence and magnitude of tree transpiration and dielectric constant changes in stems.
Stroh, Esther D.; Miller, Joel P.
2009-01-01
The Niobrara River Valley in north-central Nebraska supports scattered stands of paper birch (Betula papyrifera Marsh), a species more typical of boreal forests. These birch stands are considered to be relictual populations that have persisted since the end of the Wisconsin glaciation, when regional flora was more boreal in nature (Wright 1970, Kaul and others, 1988). Dieback of canopy-sized birch has been observed throughout the Niobrara Valley in recent years, although no onset dates are documented. The current dieback event probably started around or after the early 1980’s. The study objectives were to understand microclimatic conditions in birch stands relative to nearby weather stations and historic weather conditions, and to assess current health conditions of individual birch trees. Temperature was measured every half-hour from June 2005 through October 2007 in 12 birch stands and individual birch tree health was measured as expressed by percent living canopy in these and 13 additional stands in spring 2006 and 2007. Birch site microclimate was compared to data from a National Weather Service station in Valentine, Nebraska, and to an automated weather station at The Nature Conservancy Niobrara Valley Preserve 24 kilometers north of Johnstown, Nebraska. Historic weather data from the Valentine station and another National Weather Service Station at Ainsworth, Nebraska, were used to reconstruct minimum and maximum temperature at The Nature Conservancy and one microclimate monitoring station using Kalman filtering and smoothing algorithms. Birch stand microclimate differed from local weather stations as well as among stands. Birch health was associated with annual minimum temperature regimes; those stands whose annual daily minimum temperature regimes were most like The Nature Conservancy station contained smaller proportions of living trees. Frequency of freeze/thaw conditions capable of inducing rootlet injury and subsequent crown dieback significantly have increased in the second one-half of the period of record (1978–2007) as compared to the first one-half (1948–1977). River location was associated with birch health; upper river sites had significantly healthier trees than north bank sites. Localized microclimates in the birch stands have likely facilitated the persistence of the birch populations in a region otherwise unsuitable for the species. These microclimate differences may reduce frequency of thaw/freeze conditions that can induce root injury and potential crown dieback. A large population decline in the context of increased frequency of potentially injurious climatic events would make population recovery much more difficult now than from 1948 to 1977, when thaw/freeze conditions were less frequent. These conditions, combined with little evidence of recruitment of young birch and great geographic distances from potential immigrant sources, make the future persistence of birch in the Niobrara River Valley stands uncertain.
Soil microclimate monitoring in forested and meadow sites
NASA Astrophysics Data System (ADS)
Freyerova, Katerina; Safanda, Jan
2016-04-01
It is well known fact that forest microclimate differs from open area microclimate (Geiger 1965). Less attention is paid to soil temperatures and their long-term monitoring. To evaluate and compare these two environments from the soil microclimate point of view, Institute of Geophysics in Prague monitors soil and air temperatures in Bedřichov in the Jizerské Hory Mountains (Czech Republic). The soil temperatures are measured in three depths (20, 50 and 100 cm) in forest (700 m a. s. l.) and meadow (750 m a. s. l.). Air temperatures are measured at 2m height both in forest and meadow. Nowadays, we have more than three years long time series. The most of studies and experiments described in literature are short-term ones (in order of days or weeks). However, from short-term experiments the seasonal behaviour and trends can be hardly identified and conclusions on soil temperature reaction to climatic extremes such as heat waves, drought or freeze cannot be done with confidence. These drawbacks of the short-term experiments are discussed in literature (eg. Morecroft et al. 1998; Renaud et al. 2011). At the same, with progression of the global warming, the expected increasing frequency of climatic extremes will affect the future form of forest vegetation (Von Arx et al. 2012). The soil and air temperature series, both from the forest and meadow sites, are evaluated and interpreted with respect to long term temperature characteristics and seasonal trends. The emphasis is given on the soil temperature responses to extreme climatic situations. We examine variability between the localities and depths and spatial and temporal changes in this variability. This long-term monitoring allows us to better understand and examine the behaviour of the soil temperature in extreme weather situations. Therefore, we hope to contribute to better prediction of future reactions of this specific environments to the climate change. Literature Geiger, R., 1965. The climate near the ground, Harvard University Press. Available at: https://books.google.cz/books?id=fTpRAAAAMAAJ. Morecroft, M.D., Taylor, M.E. & Oliver, H.R., 1998. Air and soil microclimates of deciduous woodland compared to an open site. Agricultural and Forest Meteorology, 90(1-2), pp.141-156. Renaud, V. et al., 2011. Comparison between open-site and below-canopy climatic conditions in Switzerland for different types of forests over 10 years (1998-2007). Theoretical and Applied Climatology, 105(1-2), pp.119-127. Available at: http://link.springer.com/10.1007/s00704-010-0361-0. Von Arx, G., Dobbertin, M. & Rebetez, M., 2012. Spatio-temporal effects of forest canopy on understory microclimate in a long-term experiment in Switzerland. Agricultural and Forest Meteorology, 166-167, pp.144-155. Available at: http://dx.doi.org/10.1016/j.agrformet.2012.07.018.
Tucker, Colin; McHugh, Theresa A.; Howell, Armin; Gill, Richard; Weber, Bettina; Belnap, Jayne; Grote, Ed; Reed, Sasha C.
2017-01-01
Carbon cycling associated with biological soil crusts, which occupy interspaces between vascular plants in drylands globally, may be an important part of the coupled climate-carbon cycle of the Earth system. A major challenge to understanding CO2 fluxes in these systems is that much of the biotic and biogeochemical activity occurs in the upper few mm of the soil surface layer (i.e., the ‘mantle of fertility’), which exhibits highly dynamic and difficult to measure temperature and moisture fluctuations. Here, we report a multi-sensor approach to simultaneously measuring temperature and moisture of this biocrust surface layer (0–2 mm), and the deeper soil profile, concurrent with automated measurement of surface soil CO2effluxes. Our results illuminate robust relationships between biocrust water content and field CO2 pulses that have previously been difficult to detect and explain. All observed CO2 pulses over the measurement period corresponded to surface wetting events, including when the wetting events did not penetrate into the soil below the biocrust layer (0–2 mm). The variability of temperature and moisture of the biocrust surface layer was much greater than even in the 0–5 cm layer of the soil beneath the biocrust, or deeper in the soil profile. We therefore suggest that coupling surface measurements of biocrust moisture and temperature to automated CO2flux measurements may greatly improve our understanding of the climatic sensitivity of carbon cycling in biocrusted interspaces in our study region, and that this method may be globally relevant and applicable.
Controlled cooling of an electronic system for reduced energy consumption
DOE Office of Scientific and Technical Information (OSTI.GOV)
David, Milnes P.; Iyengar, Madhusudan K.; Schmidt, Roger R.
Energy efficient control of a cooling system cooling an electronic system is provided. The control includes automatically determining at least one adjusted control setting for at least one adjustable cooling component of a cooling system cooling the electronic system. The automatically determining is based, at least in part, on power being consumed by the cooling system and temperature of a heat sink to which heat extracted by the cooling system is rejected. The automatically determining operates to reduce power consumption of the cooling system and/or the electronic system while ensuring that at least one targeted temperature associated with the coolingmore » system or the electronic system is within a desired range. The automatically determining may be based, at least in part, on one or more experimentally obtained models relating the targeted temperature and power consumption of the one or more adjustable cooling components of the cooling system.« less
Wilkinson, Sally; Davies, William J
2008-01-01
The apoplastic pH of intact Forsythiaxintermedia (cv. Lynwood) and tomato (Solanum lycopersicum) plants has been manipulated using buffered foliar sprays, and thereby stomatal conductance (g(s)), leaf growth rate, and plant water loss have been controlled. The more alkaline the pH of the foliar spray, the lower the g(s) and/or leaf growth rate subsequently measured. The most alkaline pH that was applied corresponds to that measured in sap extracted from shoots of tomato and Forsythia plants experiencing, respectively, soil drying or a relatively high photon flux density (PFD), vapour pressure deficit (VPD), and temperature in the leaf microclimate. The negative correlation between PFD/VPD/temperature and g(s) determined in well-watered Forsythia plants exposed to a naturally varying summer microclimate was eliminated by spraying the plants with relatively alkaline but not acidic buffers, providing evidence for a novel pH-based signalling mechanism linking the aerial microclimate with stomatal aperture. Increasing the pH of the foliar spray only reduced g(s) in plants of the abscisic acid (ABA)-deficient flacca mutant of tomato when ABA was simultaneously sprayed onto leaves or injected into stems. In well-watered Forsythia plants exposed to a naturally varying summer microclimate (variable PFD, VPD, and temperature), xylem pH and leaf ABA concentration fluctuated but were positively correlated. Manipulation of foliar apoplastic pH also affected the response of g(s) and leaf growth to ABA injected into stems of intact Forsythia plants. The techniques used here to control physiology and water use in intact growing plants could easily be applied in a horticultural context.
NASA Astrophysics Data System (ADS)
Ozbay, G.; Sriharan, S.; Fan, C.; Adolf, J.
2015-12-01
Undergraduate student experiential learning activities focused on microclimates of Hawai'i Island, Hawai'i. Six students from Virginia State University, three students from Delaware State University and faculty advisors were hosted by the University of Hawai'i at Hilo (UHH) Department of Marine Science. This partnership provided integrated, cohesive, and innovative education and research capabilities to minority students on climate change science. Activities included a summer course, instrumentation training, field and laboratory research training, sampling, data collection, logging, analysis, interpretation, report preparation, and research presentation. Most training activities used samples collected during students' field sampling in Hilo Bay. Water quality and phytoplankton data were collected along a 220 degree line transect from the mouth of the Wailuku River to the pelagic zone outside of Hilo Bay into the Pacific Ocean to a distance of 15.5 km. Water clarity, turbidity, chlorophyll, physical water quality parameters, and atmospheric CO2 levels were measured along the transect. Phytoplankton samples were collected for analysis by Scanning Electron Microscopy and Flow Cytometry. Data showed the extent of anthropogenic activity on water quality, with implications for food web dynamics. In addition, atmospheric CO2 concentration, island vegetation, and GPS points were recorded throughout the island of Hawai'i to investigate how variations in microclimate, elevation, and land development affect the amount of CO2 in the atmosphere, vegetation, and water quality. Water quality results at locations near rivers were completely different from other study sites, requiring students' critical thinking skills to find possible reasons for the difference. Our data show a correlation between population density and CO2 concentrations. Anthropogenic activities affecting CO2 and ocean conditions in Hawaiian microclimates can potentially have deleterious effects on the life that call these areas home.
He, Yufei; D'Odorico, Paolo; De Wekker, Stephan F J
2015-06-01
Many arid and semi-arid landscapes around the world are affected by a shift from grassland to shrubland vegetation, presumably induced by climate warming, increasing atmospheric CO2 concentrations, and/or changing land use. This major change in vegetation cover is likely sustained by positive feedbacks with the physical environment. Recent research has focused on a feedback with microclimate, whereby cold intolerant shrubs increase the minimum nocturnal temperatures in their surroundings. Despite the rich literature on the impact of land cover change on local climate conditions, changes in microclimate resulting from shrub expansion into desert grasslands have remained poorly investigated. It is unclear to what extent such a feedback can affect the maximum extent of shrub expansion and the configuration of a stable encroachment front. Here, we focus on the case of the northern Chihuahuan desert, where creosotebush (Larrea tridentata) has been replacing grasslands over the past 100-150 years. We use a process-based coupled atmosphere-vegetation model to investigate the role of this feedback in sustaining shrub encroachment in the region. Simulations indicate that the feedback allows juvenile shrubs to establish in the grassland during average years and, once established, reduce their vulnerability to freeze-induced mortality by creating a warmer microclimate. Such a feedback is crucial in extreme cold winters as it may reduce shrub mortality. We identify the existence of a critical zone in the surroundings of the encroachment front, in which vegetation dynamics are bistable: in this zone, vegetation can be stable both as grassland and as shrubland. The existence of these alternative stable states explains why in most cases the shift from grass to shrub cover is found to be abrupt and often difficult to revert. © 2015 John Wiley & Sons Ltd.
Davey, C.A.; Pielke, R.A.; Gallo, K.P.
2006-01-01
There is currently much attention being given to the observed increase in near-surface air temperatures during the last century. The proper investigation of heating trends, however, requires that we include surface heat content to monitor this aspect of the climate system. Changes in heat content of the Earth's climate are not fully described by temperature alone. Moist enthalpy or, alternatively, equivalent temperature, is more sensitive to surface vegetation properties than is air temperature and therefore more accurately depicts surface heating trends. The microclimates evident at many surface observation sites highlight the influence of land surface characteristics on local surface heating trends. Temperature and equivalent temperature trend differences from 1982-1997 are examined for surface sites in the Eastern U.S. Overall trend differences at the surface indicate equivalent temperature trends are relatively warmer than temperature trends in the Eastern U.S. Seasonally, equivalent temperature trends are relatively warmer than temperature trends in winter and are relatively cooler in the fall. These patterns, however, vary widely from site to site, so local microclimate is very important. ?? 2006 Elsevier B.V. All rights reserved.
Hübner, Sariel; Rashkovetsky, Eugenia; Kim, Young Bun; Oh, Jung Hun; Michalak, Katarzyna; Weiner, Dmitry; Korol, Abraham B.; Nevo, Eviatar; Michalak, Pawel
2013-01-01
The opposite slopes of “Evolution Canyon” in Israel have served as a natural model system of adaptation to a microclimate contrast. Long-term studies of Drosophila melanogaster populations inhabiting the canyon have exhibited significant interslope divergence in thermal and drought stress resistance, candidate genes, mobile elements, habitat choice, mating discrimination, and wing-shape variation, all despite close physical proximity of the contrasting habitats, as well as substantial interslope migration. To examine patterns of genetic differentiation at the genome-wide level, we used high coverage sequencing of the flies’ genomes. A total of 572 genes were significantly different in allele frequency between the slopes, 106 out of which were associated with 74 significantly overrepresented gene ontology (GO) terms, particularly so with response to stimulus and developmental and reproductive processes, thus corroborating previous observations of interslope divergence in stress response, life history, and mating functions. There were at least 37 chromosomal “islands” of interslope divergence and low sequence polymorphism, plausible signatures of selective sweeps, more abundant in flies derived from one (north-facing) of the slopes. Positive correlation between local recombination rate and the level of nucleotide polymorphism was also found. PMID:24324170
46 CFR 153.432 - Cooling systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 5 2012-10-01 2012-10-01 false Cooling systems. 153.432 Section 153.432 Shipping COAST... Control Systems § 153.432 Cooling systems. (a) Each cargo cooling system must have an equivalent standby... cooling system. (b) Each tankship that has a cargo tank with a required cooling system must have a manual...
46 CFR 153.432 - Cooling systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 5 2013-10-01 2013-10-01 false Cooling systems. 153.432 Section 153.432 Shipping COAST... Control Systems § 153.432 Cooling systems. (a) Each cargo cooling system must have an equivalent standby... cooling system. (b) Each tankship that has a cargo tank with a required cooling system must have a manual...
46 CFR 153.432 - Cooling systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 5 2011-10-01 2011-10-01 false Cooling systems. 153.432 Section 153.432 Shipping COAST... Control Systems § 153.432 Cooling systems. (a) Each cargo cooling system must have an equivalent standby... cooling system. (b) Each tankship that has a cargo tank with a required cooling system must have a manual...
46 CFR 153.432 - Cooling systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false Cooling systems. 153.432 Section 153.432 Shipping COAST... Control Systems § 153.432 Cooling systems. (a) Each cargo cooling system must have an equivalent standby... cooling system. (b) Each tankship that has a cargo tank with a required cooling system must have a manual...
NASA Technical Reports Server (NTRS)
Machablishvili, O. G.
1980-01-01
The thermal state of women during the effect of high air temperature and relative humidity with a varying degree of physical loads was studied. Parameters for air temperature, relative humidity, and air movement were established. It was established that in women the thermo-regulatory stress occurs at lower air temperatures and with lower physical loads than in men. The accumulation of heat in women was revealed with lower air temperature than in men. It is concluded that to preserve the normal physiological state of the female organism it is necessary to create more favorable microclimate conditions and decrease the physical loads.
Sedov, A V; Lukicheva, T A; Surovtsev, N A; Akin'shin, A V; Nazarov, L Iu; Miroshnik, S V
1993-01-01
A group of volunteers was exposed to coaction of carbon dioxide (concentration 300 mg/cu m) and heating microclimate (ambient temperature +50 +/- 2 degrees C, relative humidity 20 +/- 5%), simultaneously they received one of the medicines: placebo, bemitil (0.5 g), bromantane (0.25 g) or bemitil (0.5 g) combined with bromantane (0.25 g). Bromantane (0.25 g) or bemitil (0.5 g) combined with bromantane (0.25 g) were proved to be the most effective method to increase stability of the human body against co-action of carbon dioxide and heating microclimate.
Mantilla-Contreras, Jasmin
2018-01-01
Environmental and leaf trait effects on herbivory are supposed to vary among different feeding guilds. Herbivores also show variability in their preferences for plant ontogenetic stages. Along the vertical forest gradient, environmental conditions change, and trees represent juvenile and adult individuals in the understorey and canopy, respectively. This study was conducted in ten forests sites in Central Germany for the enrichment of canopy research in temperate forests. Arthropod herbivory of different feeding traces was surveyed on leaves of Fagus sylvatica Linnaeus (European beech; Fagaceae) in three strata. Effects of microclimate, leaf traits, and plant ontogenetic stage were analyzed as determining parameters for herbivory. The highest herbivory was caused by exophagous feeding traces. Herbivore attack levels varied along the vertical forest gradient for most feeding traces with distinct patterns. If differences of herbivory levels were present, they only occurred between juvenile and adult F. sylvatica individuals, but not between the lower and upper canopy. In contrast, differences of microclimate and important leaf traits were present between the lower and upper canopy. In conclusion, the plant ontogenetic stage had a stronger effect on herbivory than microclimate or leaf traits along the vertical forest gradient. PMID:29373542
Analyzing the edge effects in a Brazilian seasonally dry tropical forest.
Arruda, D M; Eisenlohr, P V
2016-02-01
Due to the deciduous nature of dry forests (widely known as seasonally dry tropical forests) they are subject to microclimatic conditions not experienced in other forest formations. Close examinations of the theory of edge effects in dry forests are still rare and a number of questions arise in terms of this topic. In light of this situation we examined a fragment of the dry forest to respond to the following questions: (I) Are there differences in canopy cover along the edge-interior gradient during the dry season? (II) How does the microclimate (air temperature, soil temperature, and relative humidity) vary along that gradient? (III) How does the microclimate influence tree species richness, evenness and abundance along that gradient? (IV) Are certain tree species more dominant closer to the forest edges? Regressions were performed to address these questions. Their coefficients did not significantly vary from zero. Apparently, the uniform openness of the forest canopy caused a homogeneous internal microclimate, without significant differentiation in habitats that would allow modifications in biotic variables tested. We conclude that the processes of edge effect commonly seen in humid forests, not was shared with the dry forest assessed.
NASA Astrophysics Data System (ADS)
Hannah, David M.; Gurnell, Angela M.; McGregor, Glenn R.
2000-06-01
Climatic processes, operating at a range of scales, drive energy fluxes at the glacier surface which control meltwater generation and ultimately runoff. Nevertheless, to date, most glacier microclimate research has been both temporally (short-term) and spatially (single station) restricted. This paper addresses this knowledge gap by reporting on a detailed, empirical study which characterizes spatio-temporal variations in and linkages between glacier microclimate, surface energy and mass exchanges within a small glacierized cirque (Taillon Glacier, French Pyrénées) over two melt seasons. Data collected at five automatic weather stations (AWSs) and over ablation stake networks suggest that topoclimates, altitude and transient snowline position primarily determine the distribution of glacier energy receipt and, in turn, snow- and ice-melt patterns. Generally net radiation is the dominant energy source, followed by sensible heat, while latent heat is an energy sink. However, the magnitude and partitioning of energy balance terms, and consequently ablation, vary across the glacier both seasonally and with prevailing weather conditions. Importantly, this paper demonstrates that such monitoring programmes are required to truly represent and provide a sound basis for modelling glacier energy and mass-balances in both space and time.
DOE Office of Scientific and Technical Information (OSTI.GOV)
David, Milnes P.; Iyengar, Madhusudan K.; Schmidt, Roger R.
Energy efficient control of a cooling system cooling an electronic system is provided. The control includes automatically determining at least one adjusted control setting for at least one adjustable cooling component of a cooling system cooling the electronic system. The automatically determining is based, at least in part, on power being consumed by the cooling system and temperature of a heat sink to which heat extracted by the cooling system is rejected. The automatically determining operates to reduce power consumption of the cooling system and/or the electronic system while ensuring that at least one targeted temperature associated with the coolingmore » system or the electronic system is within a desired range. The automatically determining may be based, at least in part, on one or more experimentally obtained models relating the targeted temperature and power consumption of the one or more adjustable cooling components of the cooling system.« less
Li, Zhigang; Chen, Dan; Cai, Shize; Che, Shengquan
2018-01-01
Mitigating extreme heat in urban areas is beneficial and sometimes critical to human health. Thriving plant communities in community parks play an important role in mitigating extreme heat through providing cooling effect, while inevitably affecting how people perceive the benefits of using community parks for recreation. Thus, the impacts of plant communities on the thermal environment should be quantified to determine the optimal structure of the plant community. The goal would be to harmonize the functions of improving the thermal environment with the preferences people have related to the recreational benefits of plant communities with various levels of vegetation density. In this paper, the correlations between the structural characteristics of plant communities and their function in mitigating the thermal environment were investigated on calm summer days in Xincheng Central Park, Minhang District, Shanghai, China. In addition to analyzing the plant communities present and their effects on the park microclimate, a questionnaire was employed to determine the plant community preferences of recreational park users. The results showed that plant communities could reduce the air temperature by 1.23-2.42 °C and increase the relative humidity by 2.4-4.2% during the daytime. The microclimate conditions in plant communities with varying vegetation densities were significantly different. The canopy density and leaf area index primarily controlled the temperature reduction, while the canopy density and total canopy cover ratio primarily controlled the increase in humidity; meanwhile, these correlations varied at different times of the day. Moreover, most of the park users preferred a moderately dense plant community which met their environmental perceptions for recreation in parks. Age or education level variables of park users would also predict preferences for different plant community densities. Ultimately, one plant community pattern with appropriate canopy density (60%), leaf area index (≥3) and canopy cover ratio (total 0.80-1.20, with 0.6-0.75 for trees and 0.20-0.45 for shrubs/woodland area) was recommended, which would harmonize the functions of the mitigation of the thermal environment with most people's perception of a desirable vegetation density.
Impacts of Vegetation and Urban planning on micro climate in Hashtgerd new Town
NASA Astrophysics Data System (ADS)
Sodoudi, Sahar; langer, Ines; Cubasch, Ulrich
2013-04-01
One of the objectives of climatological part of project Young Cities 'Developing Energy-Efficient Urban Fabric in the Tehran-Karaj Region' is to simulate the micro climate (with 1m resolution) in 35ha of new town Hashtgerd, which is located 65 km far from mega city Tehran. The Project aims are developing, implementing and evaluating building and planning schemes and technologies which allow to plan and build sustainable, energy-efficient and climate sensible form mass housing settlements in arid and semi-arid regions ("energy-efficient fabric"). Climate sensitive form also means designing and planning for climate change and its related effects for Hashtgerd New Town. By configuration of buildings and open spaces according to solar radiation, wind and vegetation, climate sensitive urban form can create outdoor thermal comfort. To simulate the climate on small spatial scales, the micro climate model Envi-met has been used to simulate the micro climate in 35 ha. The Eulerian model ENVI-met is a micro-scale climate model which gives information about the influence of architecture and buildings as well as vegetation and green area on the micro climate up to 1 m resolution. Envi-met has been run with information from topography, downscaled climate data with neuro-fuzzy method, meteorological measurements, building height and different vegetation variants (low and high number of trees) Through the optimal Urban Design and Planning for the 35ha area the microclimate results shows, that with vegetation the microclimate in street canopies will be change: • 2 m temperature is decreased by about 2 K • relative humidity increase by about 10 % • soil temperature is decreased by about 3 K • wind speed is decreased by about 60% The style of buildings allows free movement of air, which is of high importance for fresh air supply. The increase of inbuilt areas in 35 ha reduces the heat island effect through cooling caused by vegetation and increase of air humidity which caused by trees evaporation. The downscaled climate scenarios considering new urban planning strategies in 35ha will be presented till 2100.
Li, Zhigang; Chen, Dan; Cai, Shize; Che, Shengquan
2018-01-01
Mitigating extreme heat in urban areas is beneficial and sometimes critical to human health. Thriving plant communities in community parks play an important role in mitigating extreme heat through providing cooling effect, while inevitably affecting how people perceive the benefits of using community parks for recreation. Thus, the impacts of plant communities on the thermal environment should be quantified to determine the optimal structure of the plant community. The goal would be to harmonize the functions of improving the thermal environment with the preferences people have related to the recreational benefits of plant communities with various levels of vegetation density. In this paper, the correlations between the structural characteristics of plant communities and their function in mitigating the thermal environment were investigated on calm summer days in Xincheng Central Park, Minhang District, Shanghai, China. In addition to analyzing the plant communities present and their effects on the park microclimate, a questionnaire was employed to determine the plant community preferences of recreational park users. The results showed that plant communities could reduce the air temperature by 1.23–2.42 °C and increase the relative humidity by 2.4–4.2% during the daytime. The microclimate conditions in plant communities with varying vegetation densities were significantly different. The canopy density and leaf area index primarily controlled the temperature reduction, while the canopy density and total canopy cover ratio primarily controlled the increase in humidity; meanwhile, these correlations varied at different times of the day. Moreover, most of the park users preferred a moderately dense plant community which met their environmental perceptions for recreation in parks. Age or education level variables of park users would also predict preferences for different plant community densities. Ultimately, one plant community pattern with appropriate canopy density (60%), leaf area index (≥3) and canopy cover ratio (total 0.80–1.20, with 0.6–0.75 for trees and 0.20–0.45 for shrubs/woodland area) was recommended, which would harmonize the functions of the mitigation of the thermal environment with most people’s perception of a desirable vegetation density. PMID:29694401
Compressor bleed cooling fluid feed system
Donahoo, Eric E; Ross, Christopher W
2014-11-25
A compressor bleed cooling fluid feed system for a turbine engine for directing cooling fluids from a compressor to a turbine airfoil cooling system to supply cooling fluids to one or more airfoils of a rotor assembly is disclosed. The compressor bleed cooling fluid feed system may enable cooling fluids to be exhausted from a compressor exhaust plenum through a downstream compressor bleed collection chamber and into the turbine airfoil cooling system. As such, the suction created in the compressor exhaust plenum mitigates boundary layer growth along the inner surface while providing flow of cooling fluids to the turbine airfoils.
ERIC Educational Resources Information Center
Human Engineering Inst., Cleveland, OH.
THIS MODULE OF A 30-MODULE COURSE IS DESIGNED TO DEVELOP AN UNDERSTANDING OF THE FUNCTION AND MAINTENANCE OF THE DIESEL ENGINE COOLING SYSTEM AND THE PROCEDURES FOR TRANSMISSION INSTALLATION. TOPICS ARE (1) IMPORTANCE OF THE COOLING SYSTEM, (2) COOLING SYSTEM COMPONENTS, (3) EVALUATING COOLING SYSTEM FAILURES, (4) CARING FOR THE COOLING SYSTEM,…
Split radiator design for heat rejection optimization for a waste heat recovery system
Ernst, Timothy C.; Nelson, Christopher R.
2016-10-18
A cooling system provides improved heat recovery by providing a split core radiator for both engine cooling and condenser cooling for a Rankine cycle (RC). The cooling system includes a radiator having a first cooling core portion and a second cooling core portion. An engine cooling loop is fluidly connected the second cooling core portion. A condenser of an RC has a cooling loop fluidly connected to the first cooling core portion. A valve is provided between the engine cooling loop and the condenser cooling loop adjustably control the flow of coolant in the condenser cooling loop into the engine cooling loop. The cooling system includes a controller communicatively coupled to the valve and adapted to determine a load requirement for the internal combustion engine and adjust the valve in accordance with the engine load requirement.
Controlled cooling of an electronic system based on projected conditions
David, Milnes P.; Iyengar, Madhusudan K.; Schmidt, Roger R.
2016-05-17
Energy efficient control of a cooling system cooling an electronic system is provided based, in part, on projected conditions. The control includes automatically determining an adjusted control setting(s) for an adjustable cooling component(s) of the cooling system. The automatically determining is based, at least in part, on projected power consumed by the electronic system at a future time and projected temperature at the future time of a heat sink to which heat extracted is rejected. The automatically determining operates to reduce power consumption of the cooling system and/or the electronic system while ensuring that at least one targeted temperature associated with the cooling system or the electronic system is within a desired range. The automatically determining may be based, at least in part, on an experimentally obtained model(s) relating the targeted temperature and power consumption of the adjustable cooling component(s) of the cooling system.
Controlled cooling of an electronic system based on projected conditions
David, Milnes P.; Iyengar, Madhusudan K.; Schmidt, Roger R.
2015-08-18
Energy efficient control of a cooling system cooling an electronic system is provided based, in part, on projected conditions. The control includes automatically determining an adjusted control setting(s) for an adjustable cooling component(s) of the cooling system. The automatically determining is based, at least in part, on projected power consumed by the electronic system at a future time and projected temperature at the future time of a heat sink to which heat extracted is rejected. The automatically determining operates to reduce power consumption of the cooling system and/or the electronic system while ensuring that at least one targeted temperature associated with the cooling system or the electronic system is within a desired range. The automatically determining may be based, at least in part, on an experimentally obtained model(s) relating the targeted temperature and power consumption of the adjustable cooling component(s) of the cooling system.
Passive cooling system for top entry liquid metal cooled nuclear reactors
Boardman, Charles E.; Hunsbedt, Anstein; Hui, Marvin M.
1992-01-01
A liquid metal cooled nuclear fission reactor plant having a top entry loop joined satellite assembly with a passive auxiliary safety cooling system for removing residual heat resulting from fuel decay during shutdown, or heat produced during a mishap. This satellite type reactor plant is enhanced by a backup or secondary passive safety cooling system which augments the primary passive auxiliary cooling system when in operation, and replaces the primary cooling system when rendered inoperative.
Pandolf, Kent B; Francesconi, Ralph; Sawka, Michael N; Cymerman, Allen; Hoyt, Reed W; Young, Andrew J; Zambraski, Edward J
2011-12-01
The United States Army Research Institute of Environmental Medicine (USARIEM) celebrated its 50th anniversary on July 1, 2011. This article reviews its history, evolution, and transition of its research programs as well as its scientific and military accomplishments, emphasizing the past 25 yr. During the 1990s, USARIEM published a series of pocket guides providing guidance for sustaining Warfighter health and performance in Southwest Asia, Somalia, the former Republic of Yugoslavia, Rwanda, and Haiti. Issues identified during Operation Desert Storm elicited research that improved nutritional guidelines for protracted desert operations; safer use of nuclear, chemical, and biological protective clothing; equipment, development, and fielding of efficient microclimate cooling systems; and effective evaluation of pharmaceuticals to protect soldiers from chemical and biological threats. During the first decade of the 21st century, USARIEM and the Department of the Army published official medical/performance doctrines for operations in the heat and cold and at high altitude. The current Global War on Terrorism focused research to improve doctrines for hot, cold, and high-altitude operations, reduce musculoskeletal training injuries, provide improved field nutrition, more efficient planning for operational water requirements, and improve both military clothing and materiel. This article also describes the critically important interactions and communications between USARIEM and deployed units and the benefits to Warfighters from this association. This report presents USARIEM's unique and world-class facilities, organizational changes, scientific and support personnel, and major research accomplishments, including the publication of 2,200 scientific papers over the past 25 yr.
2014-01-01
The objective of this study was to develop suitable cooling systems for high-power multichip LEDs. To this end, three different active cooling systems were investigated to control the heat generated by the powering of high-power multichip LEDs in two different configurations (30 and 2 × 15 W). The following cooling systems were used in the study: an integrated multi-fin heat sink design with a fan, a cooling system with a thermoelectric cooler (TEC), and a heat pipe cooling device. According to the results, all three systems were observed to be sufficient for cooling high-power LEDs. Furthermore, it was observed that the integrated multifin heat sink design with a fan was the most efficient cooling system for a 30 W high-power multichip LED. The cooling system with a TEC and 46 W input power was the most efficient cooling system for 2 × 15 W high-power multichip LEDs. PMID:25162058
Performance assessment of a photonic radiative cooling system for office buildings
Wang, Weimin; Fernandez, Nick; Katipamula, Srinivas; ...
2017-11-08
Recent advances in materials have demonstrated the ability to maintain radiator surfaces at below-ambient temperatures in the presence of intense, direct sunlight. Daytime radiative cooling is promising for building applications. Here, this paper estimates the energy savings from daytime radiative cooling, specifically based on photonic materials. A photonic radiative cooling system was proposed and modeled using the whole energy simulation program EnergyPlus. A typical medium-sized office building was used for the simulation analysis. Several reference systems were established to quantify the potential of energy savings from the photonic radiative cooling system. The reference systems include a variable-air-volume (VAV) system, amore » hydronic radiant system, and a nighttime radiative cooling system. The savings analysis was made for a number of locations with different climates. Simulation results showed that the photonic radiative cooling system saved between 45% and 68% cooling electricity relative to the VAV system and between 9% and 23% relative to the nighttime radiative cooling system featured with the best coating commercially available on market. Finally, a simple economic analysis was also made to estimate the maximum acceptable incremental cost for upgrading from nighttime cooling to photonic radiative cooling.« less
Performance assessment of a photonic radiative cooling system for office buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Weimin; Fernandez, Nick; Katipamula, Srinivas
Recent advances in materials have demonstrated the ability to maintain radiator surfaces at below-ambient temperatures in the presence of intense, direct sunlight. Daytime radiative cooling is promising for building applications. Here, this paper estimates the energy savings from daytime radiative cooling, specifically based on photonic materials. A photonic radiative cooling system was proposed and modeled using the whole energy simulation program EnergyPlus. A typical medium-sized office building was used for the simulation analysis. Several reference systems were established to quantify the potential of energy savings from the photonic radiative cooling system. The reference systems include a variable-air-volume (VAV) system, amore » hydronic radiant system, and a nighttime radiative cooling system. The savings analysis was made for a number of locations with different climates. Simulation results showed that the photonic radiative cooling system saved between 45% and 68% cooling electricity relative to the VAV system and between 9% and 23% relative to the nighttime radiative cooling system featured with the best coating commercially available on market. Finally, a simple economic analysis was also made to estimate the maximum acceptable incremental cost for upgrading from nighttime cooling to photonic radiative cooling.« less
microclim: Global estimates of hourly microclimate based on long-term monthly climate averages
Kearney, Michael R; Isaac, Andrew P; Porter, Warren P
2014-01-01
The mechanistic links between climate and the environmental sensitivities of organisms occur through the microclimatic conditions that organisms experience. Here we present a dataset of gridded hourly estimates of typical microclimatic conditions (air temperature, wind speed, relative humidity, solar radiation, sky radiation and substrate temperatures from the surface to 1 m depth) at high resolution (~15 km) for the globe. The estimates are for the middle day of each month, based on long-term average macroclimates, and include six shade levels and three generic substrates (soil, rock and sand) per pixel. These data are suitable for deriving biophysical estimates of the heat, water and activity budgets of terrestrial organisms. PMID:25977764
Microclim: Global estimates of hourly microclimate based on long-term monthly climate averages.
Kearney, Michael R; Isaac, Andrew P; Porter, Warren P
2014-01-01
The mechanistic links between climate and the environmental sensitivities of organisms occur through the microclimatic conditions that organisms experience. Here we present a dataset of gridded hourly estimates of typical microclimatic conditions (air temperature, wind speed, relative humidity, solar radiation, sky radiation and substrate temperatures from the surface to 1 m depth) at high resolution (~15 km) for the globe. The estimates are for the middle day of each month, based on long-term average macroclimates, and include six shade levels and three generic substrates (soil, rock and sand) per pixel. These data are suitable for deriving biophysical estimates of the heat, water and activity budgets of terrestrial organisms.
Turbine airfoil with laterally extending snubber having internal cooling system
Scribner, Carmen Andrew; Messmann, Stephen John; Marsh, Jan H.
2016-09-06
A turbine airfoil usable in a turbine engine and having at least one snubber with a snubber cooling system positioned therein and in communication with an airfoil cooling system is disclosed. The snubber may extend from the outer housing of the airfoil toward an adjacent turbine airfoil positioned within a row of airfoils. The snubber cooling system may include an inner cooling channel separated from an outer cooling channel by an inner wall. The inner wall may include a plurality of impingement cooling orifices that direct impingement fluid against an outer wall defining the outer cooling channel. In one embodiment, the cooling fluids may be exhausted from the snubber, and in another embodiment, the cooling fluids may be returned to the airfoil cooling system. Flow guides may be positioned in the outer cooling channel, which may reduce cross-flow by the impingement orifices, thereby increasing effectiveness.
Liquid metal cooled nuclear reactors with passive cooling system
Hunsbedt, Anstein; Fanning, Alan W.
1991-01-01
A liquid metal cooled nuclear reactor having a passive cooling system for removing residual heat resulting from fuel decay during reactor shutdown. The passive cooling system comprises a plurality of cooling medium flow circuits which cooperate to remove and carry heat away from the fuel core upon loss of the normal cooling flow circuit to areas external thereto.
Passive cooling system for liquid metal cooled nuclear reactors with backup coolant flow path
Hunsbedt, Anstein; Boardman, Charles E.
1993-01-01
A liquid metal cooled nuclear fission reactor plant having a passive auxiliary safety cooling system for removing residual heat resulting from fuel decay during reactor shutdown, or heat produced during a mishap. This reactor plant is enhanced by a backup or secondary passive safety cooling system which augments the primary passive auxiliary cooling system when in operation, and replaces the primary system when rendered inoperable.
Non-evaporative effects of a wet mid layer on heat transfer through protective clothing.
Bröde, Peter; Havenith, George; Wang, Xiaoxin; Candas, Victor; den Hartog, Emiel A; Griefahn, Barbara; Holmér, Ingvar; Kuklane, Kalev; Meinander, Harriet; Nocker, Wolfgang; Richards, Mark
2008-09-01
In order to assess the non-evaporative components of the reduced thermal insulation of wet clothing, experiments were performed with a manikin and with human subjects in which two layers of underwear separated by an impermeable barrier were worn under an impermeable overgarment at 20 degrees C, 80% RH and 0.5 ms(-1) air velocity. By comparing manikin measurements with dry and wetted mid underwear layer, the increase in heat loss caused by a wet layer kept away from the skin was determined, which turned out to be small (5-6 W m(-2)), irrespective of the inner underwear layer being dry or wetted, and was only one third of the evaporative heat loss calculated from weight change, i.e. evaporative cooling efficiency was far below unity. In the experiments with eight males, each subject participated in two sessions with the mid underwear layer either dry or wetted, where they stood still for the first 30 min and then performed treadmill work for 60 min. Reduced heat strain due to lower insulation with the wetted mid layer was observed with decreased microclimate and skin temperatures, lowered sweat loss and cardiac strain. Accordingly, total clothing insulation calculated over the walking period from heat balance equations was reduced by 0.02 m(2) degrees C W(-1) (16%), while for the standing period the same decrease in insulation, representing 9% reduction only showed up after allowing for the lower evaporative cooling efficiency in the calculations. As evaporation to the environment and inside the clothing was restricted, the observed small alterations may be attributed to the wet mid layer's increased conductivity, which, however, appears to be of minor importance compared to the evaporative effects in the assessment of the thermal properties of wet clothing.
Integrated exhaust gas recirculation and charge cooling system
Wu, Ko-Jen
2013-12-10
An intake system for an internal combustion engine comprises an exhaust driven turbocharger configured to deliver compressed intake charge, comprising exhaust gas from the exhaust system and ambient air, through an intake charge conduit and to cylinders of the internal combustion engine. An intake charge cooler is in fluid communication with the intake charge conduit. A cooling system, independent of the cooling system for the internal combustion engine, is in fluid communication with the intake charge cooler through a cooling system conduit. A coolant pump delivers a low temperature cooling medium from the cooling system to and through the intake charge cooler for the transfer of heat from the compressed intake charge thereto. A low temperature cooler receives the heated cooling medium through the cooling system conduit for the transfer or heat therefrom.
Provisioning cooling elements for chillerless data centers
Chainer, Timothy J.; Parida, Pritish R.
2016-12-13
Systems and methods for cooling include one or more computing structure, an inter-structure liquid cooling system that includes valves configured to selectively provide liquid coolant to the one or more computing structures; a heat rejection system that includes one or more heat rejection units configured to cool liquid coolant; and one or more liquid-to-liquid heat exchangers that include valves configured to selectively transfer heat from liquid coolant in the inter-structure liquid cooling system to liquid coolant in the heat rejection system. Each computing structure further includes one or more liquid-cooled servers; and an intra-structure liquid cooling system that has valves configured to selectively provide liquid coolant to the one or more liquid-cooled servers.
NASA Astrophysics Data System (ADS)
Rankine, C. J.; Sánchez-Azofeifa, G.
2011-12-01
In the face of unprecedented global change driven by anthropogenic pressure on natural systems it has become imperative to monitor and better understand potential shifts in ecosystem functioning and services from local to global scales. The utilization of automated sensors technologies offers numerous advantages over traditional on-site ecosystem surveying techniques and, as a result, sensor networks are becoming a powerful tool in environmental monitoring programs. Tropical forests, renowned for their biodiversity, are important regulators of land-atmosphere fluxes yet the seasonally dry tropical forests, which account for 40% of forested ecosystems in the American tropics, have been severely degraded over the past several decades and not much is known of their capacity to recover. With less than 1% of these forests protected, our ability to monitor the dynamics and quantify changes in the remaining primary and recovering secondary tropical dry forests is vital to understanding mechanisms of ecosystem stress responses and climate feedback with respect to annual productivity and desertification processes in the tropics. The remote sensing component of the Tropi-Dry: Human and Biophysical Dimensions of Tropical Dry Forests in the Americas research network supports a network of long-term tropical ecosystem monitoring platforms which focus on the dynamics of seasonally dry tropical forests in the Americas. With over 25 sensor station deployments operating across a latitudinal gradient in Mexico, Costa Rica, Brazil, and Argentina continuously collecting hyper-temporal sensory input based on standardized deployment parameters, this monitoring system is unique among tropical environments. Technologies used in the network include optical canopy phenology towers, understory wireless sensing networks, above and below ground microclimate stations, and digital cameras. Sensory data streams are uploaded to a cyber-infrastructure initiative, denominated Enviro-Net°, for data storage, management, visualization, and retrieval for further analysis. The use of tower and ground-based optical sensor networks and meteorological monitoring instrumentation has proven effective in capturing seasonal growth patterns in primary and secondary forest stands. Furthermore, the observed trends in above and below ground microclimate variables are shown to closely correlate with in-situ vegetative indices (NDVI and EVI) across study sites. These long-term environmental sensory data streams provide valuable insights as to how these threatened semi-arid ecosystems regenerate after disturbances and how they respond to environmental stress such as climate change in the tropical and sub-tropical latitudes.
Preliminary design package for solar heating and cooling systems
NASA Technical Reports Server (NTRS)
1978-01-01
Summarized preliminary design information on activities associated with the development, delivery and support of solar heating and cooling systems is given. These systems are for single family dwellings and commercial applications. The heating/cooling system use a reversible vapor compression heat pump that is driven in the cooling mode by a Rankine power loop, and in the heating mode by a variable speed electric motor. The heating/cooling systems differ from the heating-only systems in the arrangement of the heat pump subsystem and the addition of a cooling tower to provide the heat sink for cooling mode operation.
Perceptions of temperature, moisture and comfort in clothing during environmental transients.
Li, Y
2005-02-22
A study has been carried out to investigate the psychophysical mechanisms of the perception of temperature and moisture sensations in clothing during environmental transients. A series of wear trials was conducted to measure the psychological perception of thermal and moisture sensations and the simultaneous temperature and humidity at the skin surface, fabric surface and in the clothing under simulated moderate rain conditions. Jumpers made from wool and acrylic fibres were used in the trial. Analysis has been carried out to study the relationship between psychological perceptions of temperature and moisture and the objectively measured skin and fabric temperatures and relative humidity in clothing microclimate. The perception of warmth seems to follow Fechner's law and Stevens' power law, having positive relationships with the skin temperature and fabric temperatures. The perception of dampness appears to follow Fechner's law more closely than Stevens' power law with a negative relationship with skin temperature, and is nonlinearly and positively correlated with relative humidity in clothing microclimate. The perception of comfort is positively related to the perception of warmth and negatively to the perception of dampness. This perception of comfort is positively related to the skin temperature, which appears to follow both Fechner's law and Stevens' law, also non-linearly and negatively related to relative humidity in clothing microclimate.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Young, Philip R.; Eyeghe-Bickong, Hans A.; du Plessis, Kari
In this paper, the metabolic and physiological impacts of an altered microclimate on quality-associated primary and secondary metabolites in grape (Vitis vinifera) ‘Sauvignon Blanc’ berries was determined in a high-altitude vineyard. The leaf and lateral shoot removal in the bunch zones altered the microclimate by increasing the exposure of the berries. The physical parameters (berry diameter and weight), primary metabolites (sugars and organic acids), as well as bunch temperature and leaf water potential were predominantly not affected by the treatment. The increased exposure led to higher levels of specific carotenoids and volatile terpenoids in the exposed berries, with earlier berrymore » stages reacting distinctly from the later developmental stages. Plastic/nonplastic metabolite responses could be further classified to identify metabolites that were developmentally controlled and/or responded to the treatment in a predictable fashion (assessed over two consecutive vintages). The study demonstrates that grapevine berries exhibit a degree of plasticity within their secondary metabolites and respond physiologically to the increased exposure by increasing metabolites with potential antioxidant activity. Finally, taken together, the data provide evidence that the underlying physiological responses relate to the maintenance of stress pathways by modulating antioxidant molecules in the berries.« less
Young, Philip R.; Eyeghe-Bickong, Hans A.; du Plessis, Kari; ...
2015-12-01
In this paper, the metabolic and physiological impacts of an altered microclimate on quality-associated primary and secondary metabolites in grape (Vitis vinifera) ‘Sauvignon Blanc’ berries was determined in a high-altitude vineyard. The leaf and lateral shoot removal in the bunch zones altered the microclimate by increasing the exposure of the berries. The physical parameters (berry diameter and weight), primary metabolites (sugars and organic acids), as well as bunch temperature and leaf water potential were predominantly not affected by the treatment. The increased exposure led to higher levels of specific carotenoids and volatile terpenoids in the exposed berries, with earlier berrymore » stages reacting distinctly from the later developmental stages. Plastic/nonplastic metabolite responses could be further classified to identify metabolites that were developmentally controlled and/or responded to the treatment in a predictable fashion (assessed over two consecutive vintages). The study demonstrates that grapevine berries exhibit a degree of plasticity within their secondary metabolites and respond physiologically to the increased exposure by increasing metabolites with potential antioxidant activity. Finally, taken together, the data provide evidence that the underlying physiological responses relate to the maintenance of stress pathways by modulating antioxidant molecules in the berries.« less
Young, Philip R; Eyeghe-Bickong, Hans A; du Plessis, Kari; Alexandersson, Erik; Jacobson, Dan A; Coetzee, Zelmari; Deloire, Alain; Vivier, Melané A
2016-03-01
In this study, the metabolic and physiological impacts of an altered microclimate on quality-associated primary and secondary metabolites in grape (Vitis vinifera) 'Sauvignon Blanc' berries was determined in a high-altitude vineyard. The leaf and lateral shoot removal in the bunch zones altered the microclimate by increasing the exposure of the berries. The physical parameters (berry diameter and weight), primary metabolites (sugars and organic acids), as well as bunch temperature and leaf water potential were predominantly not affected by the treatment. The increased exposure led to higher levels of specific carotenoids and volatile terpenoids in the exposed berries, with earlier berry stages reacting distinctly from the later developmental stages. Plastic/nonplastic metabolite responses could be further classified to identify metabolites that were developmentally controlled and/or responded to the treatment in a predictable fashion (assessed over two consecutive vintages). The study demonstrates that grapevine berries exhibit a degree of plasticity within their secondary metabolites and respond physiologically to the increased exposure by increasing metabolites with potential antioxidant activity. Taken together, the data provide evidence that the underlying physiological responses relate to the maintenance of stress pathways by modulating antioxidant molecules in the berries. © 2016 American Society of Plant Biologists. All Rights Reserved.
du Plessis, Kari; Jacobson, Dan A.
2016-01-01
In this study, the metabolic and physiological impacts of an altered microclimate on quality-associated primary and secondary metabolites in grape (Vitis vinifera) ‘Sauvignon Blanc’ berries was determined in a high-altitude vineyard. The leaf and lateral shoot removal in the bunch zones altered the microclimate by increasing the exposure of the berries. The physical parameters (berry diameter and weight), primary metabolites (sugars and organic acids), as well as bunch temperature and leaf water potential were predominantly not affected by the treatment. The increased exposure led to higher levels of specific carotenoids and volatile terpenoids in the exposed berries, with earlier berry stages reacting distinctly from the later developmental stages. Plastic/nonplastic metabolite responses could be further classified to identify metabolites that were developmentally controlled and/or responded to the treatment in a predictable fashion (assessed over two consecutive vintages). The study demonstrates that grapevine berries exhibit a degree of plasticity within their secondary metabolites and respond physiologically to the increased exposure by increasing metabolites with potential antioxidant activity. Taken together, the data provide evidence that the underlying physiological responses relate to the maintenance of stress pathways by modulating antioxidant molecules in the berries. PMID:26628747
Fantuzzi, G; Righi, E; Predieri, G; Giacobazzi, P; Mastroianni, K; Aggazzotti, G
2010-01-01
The aim of the present study was to investigate the environmental and healthy aspects from a representative sample of indoor swimming pools located in the Emilia Romagna region. During the sampling sessions, the occupational environment was evaluated in terms of microclimate parameters and thermal comfort/discomfort conditions. Moreover the chemical risk was assessed by analyzing from the pool water the presence of disinfection by-products (DBPs), such as: trihalomethanes (THMs), haloacetic acids (HAAs), chlorite, chlorate and bromate. The analytical results are in agreement with the Italian legislation (Accordo Stato-Regioni; 2003) even if in some of the sampled indoor swimming pools, the dosed combined chlorine levels, were greater than the Italian limit. With the regard to the microclimate conditions evaluation, the considered thermal indices, Predicted Mean Vote (PMV) and Predicted Percentage of Dissatisfied (PPD%), described a satisfactory occupational environment. Among DBPs, the THMs mean levels (41.4 +/- 30.0 microg/l) resulted close to the values of the current Italian drinking water legislation, and seem to not represent an health issue. The pool waters chlorate levels (range: 5 - 19537 microg/l) need further investigations as recent epidemiological studies on drinking water hypothesized a potential genotoxicity effect of these compounds which are involved in cellular oxidative processes.
Forriez, O; Masseline, J; Coadic, D; David, V; Trouiller, P; Sztrymf, B
2017-02-02
To test the effect of a new coverlet device, allowing air circulation at the body/underlying surface interface, on skin microclimate management. This prospective observational pilot study took place in a 15-bed university-affiliated intensive care unit. Overall, 34 mechanically ventilated patients were included. Skin humidity and temperature were monitored before and after the implementation of the tested device at the occiput, scapulas, buttocks and sacrum. Humidity and temperature were evaluated through surface skin impedance and an infra-red thermometer, respectively. Health professionals were asked to evaluate the device. After implementation of the coverlet device, there was a rapid, sustained and significant decrease in skin humidity at all sites ranging from 6 % to 15 %, excluding the occiput. Skin temperature also significantly decreased from 1 % at both scapulas, but not at the other studied body sites. No side effects were observed. Health professionals reported that the device was easy and quick to install. Although they did not report a subjective improvement in skin moisture or temperature, they considered the device to be efficient. Although limited by its design, this pilot study suggests a good efficacy of the studied device on skin microclimate management. Further data are warranted to test the clinical implications of our findings.
Effect of moisture transport on microclimate under T-shirts.
Dai, Xiao-Qun; Imamura, Ritsuko; Liu, Guo-Lian; Zhou, Fu-Ping
2008-09-01
Water transport through garments has influence on the microclimate between the garments and the body beneath; thus the thermal comfort feeling for the wearer. Soybean protein fiber (SPF), a new type environmental fiber, which has been reported to be superior in water transfer, is often blended with cotton to improve the water transport property. In this paper, T-shirts made of this SPF/cotton blended fabric were focused in comparison with T-shirts made of cotton fabric. Wicking and immersion tests were carried out on the two types of fabrics to investigate the water transport and absorption properties, respectively; wear trials of T-shirts made of the fabrics were also conducted. Comparing with the cotton fabric which had better water absorptive property, it was found that the blended fabric with superior wicking ability could not only delay the increase of the vapor pressure under the T-shirt at the beginning of the exercise, but also help to keep it lower through the exercise significantly, and also kept the skin temperature under the T-shirt lower. It was made clear that it is the water transfer property rather than the water absorption property helps to take away sweat quickly and prevents the increase of the humidity and temperature at skin surface, thus maintaining a comfort microclimate under garments.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mathur, Jyotirmay; Bhandari, Mahabir S; Jain, Robin
Radiant cooling system has proven to be a low energy consumption system for building cooling needs. This study describes the use of cooling tower in radiant cooling system to improve the overall system efficiency. A comprehensive simulation feasibility study of the application of cooling tower in radiant cooling system was performed for the fifteen cities in different climatic zones of India. It was found that in summer, the wet bulb temperature (WBT) of the different climatic zones except warm-humid is suitable for the integration of cooling tower with radiant cooling system. In these climates, cooling tower can provide on averagemore » 24 C to 27 C water In order to achieve the energy saving potential, three different configurations of radiant cooling system have been compared in terms of energy consumption. The different configurations of the radiant cooling system integrated with cooling tower are: (1) provide chilled water to the floor, wall and ceiling mounted tubular installation. (2) provide chilled water to the wall and ceiling mounted tabular installation. In this arrangement a separate chiller has also been used to provide chilled water at 16 C to the floor mounted tubular installation. (3) provide chilled water to the wall mounted tabular installation and a separate chiller is used to provide chilled water at 16 C to the floor and ceiling mounted tabular installation. A dedicated outdoor air system is also coupled for dehumidification and ventilation in all three configurations. A conventional all-air system was simulated as a baseline to compare these configurations for assessing the energy saving potential.« less
Cost analysis of an ammonia dry cooling system with a Chicago Bridge and Iron peak shaving system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Drost, M.K.; Johnson, B.M.
1980-12-01
A study was performed to determine the potential for reducing the cost associated with dry cooling by using an ammonia dry cooling system augmented with the Chicago Bridge and Iron (CP and I) peak shaving system. The cost analysis of an all-dry ammonia cooling system operating in conjunction with a peak shaving system is documented. The peak shaving system utilizes the excess cooling capability available at night to cool water to be used for supplemental cooling during the following day. The analysis consisted of determining the incremental cost of cooling for the CB and I system and comparing this costmore » to the incremental cost of cooling for both dry and wet/dry systems for a consistent set of design conditions and assumptions. The wet/dry systems were analyzed over a range of water usages. The basis of the comparisons was a cooling system designed for installations with a 650 mWe (gross) coal-fired power plant. From results of the study it was concluded that: the CB and I system shows a substantial economic advantage when compared with an all-dry cooling system; the CB and I system appears to be competitive with wet/dry cooling systems using about 2 to 3% water; and the CB and I system demonstrates a clear economic advantage when compared to both dry and wet/dry concepts for a winter peaking utility where the excess generation is assumed to displace both base-loaded coal-fired power generation and oil-fired gas turbine peaking units.« less
Vineyard microclimate and yield under different plastic covers.
Holcman, Ester; Sentelhas, Paulo Cesar; Conceição, Marco Antônio Fonseca; Couto, Hilton Thadeu Zarate
2018-06-01
The use of plastic cover in vineyards minimizes effects of adverse weather conditions. The northwest of São Paulo State is one of the largest grape producing regions in Brazil; however, few studies investigate the effects of different plastic covers on vineyards in this region. This study compared the effect of black shading screen (BSS) and braided polypropylene film (BPF) on BRS Morena vineyard microclimate, grown on an overhead trellis system in the northwestern São Paulo. The experiments were carried out during three growing seasons (2012-2014). BSS allowed superior incoming solar radiation (SR) transmissivity, resulting in higher net radiation (Rn), and higher ratio between photosynthetically active (PAR) and SR. No differences were observed between the average air temperatures (T) and relative humidity (RH) of covered environments (BPF and BSS) and outside condition (automatic weather station-AWS), due to high air circulation, despite wind speed (WS) reduction caused by plastic covers. BPF provided better conditions for vineyard growth with higher fruit yield than vineyard under BSS regarding the number of shoots with bunches per plant, bunch and stem weights, longitudinal diameter of berries, quantity of fertile buds per shoot, and yield per shoot and per plant. BPF covers also influenced leaf size and growth speed of plants in vineyards.
Vineyard microclimate and yield under different plastic covers
NASA Astrophysics Data System (ADS)
Holcman, Ester; Sentelhas, Paulo Cesar; Conceição, Marco Antônio Fonseca; Couto, Hilton Thadeu Zarate
2017-12-01
The use of plastic cover in vineyards minimizes effects of adverse weather conditions. The northwest of São Paulo State is one of the largest grape producing regions in Brazil; however, few studies investigate the effects of different plastic covers on vineyards in this region. This study compared the effect of black shading screen (BSS) and braided polypropylene film (BPF) on BRS Morena vineyard microclimate, grown on an overhead trellis system in the northwestern São Paulo. The experiments were carried out during three growing seasons (2012-2014). BSS allowed superior incoming solar radiation (SR) transmissivity, resulting in higher net radiation (Rn), and higher ratio between photosynthetically active (PAR) and SR. No differences were observed between the average air temperatures (T) and relative humidity (RH) of covered environments (BPF and BSS) and outside condition (automatic weather station-AWS), due to high air circulation, despite wind speed (WS) reduction caused by plastic covers. BPF provided better conditions for vineyard growth with higher fruit yield than vineyard under BSS regarding the number of shoots with bunches per plant, bunch and stem weights, longitudinal diameter of berries, quantity of fertile buds per shoot, and yield per shoot and per plant. BPF covers also influenced leaf size and growth speed of plants in vineyards.
Vineyard microclimate and yield under different plastic covers
NASA Astrophysics Data System (ADS)
Holcman, Ester; Sentelhas, Paulo Cesar; Conceição, Marco Antônio Fonseca; Couto, Hilton Thadeu Zarate
2018-06-01
The use of plastic cover in vineyards minimizes effects of adverse weather conditions. The northwest of São Paulo State is one of the largest grape producing regions in Brazil; however, few studies investigate the effects of different plastic covers on vineyards in this region. This study compared the effect of black shading screen (BSS) and braided polypropylene film (BPF) on BRS Morena vineyard microclimate, grown on an overhead trellis system in the northwestern São Paulo. The experiments were carried out during three growing seasons (2012-2014). BSS allowed superior incoming solar radiation (SR) transmissivity, resulting in higher net radiation (Rn), and higher ratio between photosynthetically active (PAR) and SR. No differences were observed between the average air temperatures (T) and relative humidity (RH) of covered environments (BPF and BSS) and outside condition (automatic weather station-AWS), due to high air circulation, despite wind speed (WS) reduction caused by plastic covers. BPF provided better conditions for vineyard growth with higher fruit yield than vineyard under BSS regarding the number of shoots with bunches per plant, bunch and stem weights, longitudinal diameter of berries, quantity of fertile buds per shoot, and yield per shoot and per plant. BPF covers also influenced leaf size and growth speed of plants in vineyards.
AUTOMOTIVE DIESEL MAINTENANCE 1. UNIT IV, MAINTAINING THE COOLING SYSTEM--DETROIT DIESEL ENGINES.
ERIC Educational Resources Information Center
Human Engineering Inst., Cleveland, OH.
THIS MODULE OF A 30-MODULE COURSE IS DESIGNED TO DEVELOP AN UNDERSTANDING OF THE OPERATION AND MAINTENANCE OF THE DIESEL ENGINE COOLING SYSTEM. TOPICS ARE PURPOSE OF THE COOLING SYSTEM, CARE MAINTENANCE OF THE COOLING SYSTEM, COOLING SYSTEM COMPONENTS, AND TROUBLESHOOTING TIPS. THE MODULE CONSISTS OF A SELF-INSTRUCTIONAL BRANCH PROGRAMED TRAINING…
A microclimate study on hypogea environments of ancient roman building.
Scatigno, C; Gaudenzi, S; Sammartino, M P; Visco, G
2016-10-01
Roman hypogea, vernacular settlements or crypts, are underground places characterised by specific and unique challenges (RH<90% and almost constant temperature throughout the whole year) related to their relative isolation from the outdoor environment. These sites often require adequate monitoring tools providing complete environmental information in order to carry out appropriate strategies for scheduling routine maintenance and designing suitable layouts for their preservation. In this work we present the results of a carefully planned thermo-hygrometric monitoring campaign conducted in a peculiar Roman building (130CE), the "Casa di Diana" Mithraeum, sited in Ostia Antica (archaeological site, Rome-Italy), with the aim of characterising the indoor environment as the structure suffers of several conservation problems (biocolonisation, efflorescences, evaporating and condensing cycle for wall-building materials). The campaign involving multipoint continuous measurement was carefully planned to better describe this micro-clime. In addition to underground environmental data available in literature, we have also performed, as a checkpoint control, a thermo-hygrometric monitoring campaign in the "Terme di Mitra" Hypogeum, a few meters from the "Casa di Diana". The recorded data was analysed by multivariate statistical and chemometric analyses. The results brought to light the presence of different microclimates (three areas) within a single Mithraeum: a room (pre-Mithraeum) and an area (Mithraeum: 2-4m) present a thermo-hygrometric environmental behaviour in accordance with a semi-confined environment, another area (Mithraeum: 1-2m) behaves accordingly with underground environments (although it cannot be described as such), and the last area (Mithraeum: 0-1m) where was recording RH values close to saturation (96-99%), associated with non-ventilated areas where the rising damp is "held" and not dispersed, describing an own micro-clime, comparable to a "small greenhouse". This study has allowed to identify some critical areas in view of planning future conservation solutions, without exporting the artefacts kept inside. Copyright © 2016 Elsevier B.V. All rights reserved.
Kleckova, Irena; Klecka, Jan
2016-01-01
Understanding the potential of animals to immediately respond to changing temperatures is imperative for predicting the effects of climate change on biodiversity. Ectothermic animals, such as insects, use behavioural thermoregulation to keep their body temperature within suitable limits. It may be particularly important at warm margins of species occurrence, where populations are sensitive to increasing air temperatures. In the field, we studied thermal requirements and behavioural thermoregulation in low-altitude populations of the Satyrinae butterflies Erebia aethiops, E. euryale and E. medusa. We compared the relationship of individual body temperature with air and microhabitat temperatures for the low-altitude Erebia species to our data on seven mountain species, including a high-altitude population of E. euryale, studied in the Alps. We found that the grassland butterfly E. medusa was well adapted to the warm lowland climate and it was active under the highest air temperatures and kept the highest body temperature of all species. Contrarily, the woodland species, E. aethiops and a low-altitude population of E. euryale, kept lower body temperatures and did not search for warm microclimates as much as other species. Furthermore, temperature-dependence of daily activities also differed between the three low-altitude and the mountain species. Lastly, the different responses to ambient temperature between the low- and high-altitude populations of E. euryale suggest possible local adaptations to different climates. We highlight the importance of habitat heterogeneity for long-term species survival, because it is expected to buffer climate change consequences by providing a variety of microclimates, which can be actively explored by adults. Alpine species can take advantage of warm microclimates, while low-altitude grassland species may retreat to colder microhabitats to escape heat, if needed. However, we conclude that lowland populations of woodland species may be more severely threatened by climate warming because of the unavailability of relatively colder microclimates. PMID:27008409
NASA Astrophysics Data System (ADS)
Percy, M.; Singha, K.; Benninger, L. K.; Riveros-Iregui, D. A.; Mirus, B. B.
2015-12-01
The spatial and temporal distribution of soil moisture in tropical critical zones depends upon a number of variables including topographic position, soil texture, overlying vegetation, and local microclimates. We investigate the influences on soil moisture on a tropical basaltic island (San Cristóbal, Galápagos) across a variety of microclimates during the transition from the wetter to the drier season. We used multiple approaches to characterize spatial and temporal patterns in soil moisture at four sites across microclimates ranging from arid to very humid. The microclimates on San Cristóbal vary with elevation, so our monitoring includes two sites in the transitional zone at lower elevations, one in the humid zone at moderate elevations, and one in the very humid zone in higher elevations. We made over 250 near-surface point measurements per site using a Hydrosense II probe, and estimated the lateral variability in soil moisture across each site with an EM-31 electrical conductivity meter. We also monitored continuous time-series of in-situ soil moisture dynamics using three nested TDR probes collocated with meteorological stations at each of the sites. Preliminary analysis indicates that soils in the very humid zone have lower electrical conductivities across all the hillslopes as compared to the humid and transitional zones, which suggests that additional factors beyond climate and slope position are important. While soil texture across the very humid site is fairly uniform, variations in vegetation have a strong control on soil moisture patterns. At the remaining sites the vegetation patterns also have a very strong local influence on soil moisture, but correlation between the depth to clay layers and soil moisture patterns suggests that mineralogy is also important. Our findings suggest that the microclimatic setting is a crucial consideration for understanding relations between vegetation, soil texture, and soil-moisture dynamics in tropical critical zones.
Intelligent Engine Systems: Thermal Management and Advanced Cooling
NASA Technical Reports Server (NTRS)
Bergholz, Robert
2008-01-01
The objective of the Advanced Turbine Cooling and Thermal Management program is to develop intelligent control and distribution methods for turbine cooling, while achieving a reduction in total cooling flow and assuring acceptable turbine component safety and reliability. The program also will develop embedded sensor technologies and cooling system models for real-time engine diagnostics and health management. Both active and passive control strategies will be investigated that include the capability of intelligent modulation of flow quantities, pressures, and temperatures both within the supply system and at the turbine component level. Thermal management system concepts were studied, with a goal of reducing HPT blade cooling air supply temperature. An assessment will be made of the use of this air by the active clearance control system as well. Turbine component cooling designs incorporating advanced, high-effectiveness cooling features, will be evaluated. Turbine cooling flow control concepts will be studied at the cooling system level and the component level. Specific cooling features or sub-elements of an advanced HPT blade cooling design will be downselected for core fabrication and casting demonstrations.
Trailer microclimate and calf welfare during fall-run transportation of beef calves in Alberta.
Goldhawk, C; Janzen, E; González, L A; Crowe, T; Kastelic, J; Pajor, E; Schwartzkopf-Genswein, K S
2014-11-01
Twenty-four commercial loads of beef calves (BW 300 ± 52 kg, mean ± SD) were evaluated for associations among transportation factors, in-transit microclimate, and calf welfare. Transport factors evaluated included vehicle speed, space allowance, compartment within trailer, and transit duration. Calves were transported for 7 h 44 min ± 4 h 15 min, with space allowances ranging from 0.56 to 1.17 m(2)/animal. Compartment within trailer, space allowance, and vehicle speed did not affect the difference between compartment ceiling-level and ambient temperatures during a 30-min period of steady-state microclimate. During the steady-state period, a 1°C increase in ambient temperature above the mean of 5.6°C was associated with a 0.62°C decrease in the difference between ceiling-level and ambient temperature (P < 0.01). Ceiling-level temperature and humidity during the first 400 min of transport could be predicted by ambient conditions and vehicle speed (pseudo-r(2) of 0.91 and 0.82 for temperature and humidity ratio; P < 0.01). Events when animal-level temperature-humidity index (THI) was classified as above the "danger" level lasted for 10.2 ± 4.1 consecutive minutes. Ambient and ceiling-level THI values were not classified as above "danger" for 90.0 and 84.9% of animal-level events. Ambient and ceiling-level THI were 5.0 ± 2.1 and 4.7 ± 2.0° Flower than animal-level THI during periods of disagreement, respectively. The majority of calves arrived in good condition and biochemical indicators of calf welfare were within reference ranges for healthy cattle. Within the study population, high pre-transport cortisol and hematocrit were associated with elevated post-transport values (P < 0.01). A 1% increase in shrink during the weaning to loading interval (24 or 48 h) decreased transportation shrink by 0.26 ± 0.04% when average animal-level temperature was greater than 5°C and decreased transportation shrink by 0.11 ± 0.04% when average animal-level temperature was less than 5°C (P < 0.01). We inferred that the study results support future investigation of the extension of in-transit microclimate as a risk factor for post-transport treatment for disease. The study also provided correction factors for estimating in-transit microclimate that could assist in evaluation of transportation management and decisions affecting profitability and calf welfare.
Aridity and decomposition processes in complex landscapes
NASA Astrophysics Data System (ADS)
Ossola, Alessandro; Nyman, Petter
2015-04-01
Decomposition of organic matter is a key biogeochemical process contributing to nutrient cycles, carbon fluxes and soil development. The activity of decomposers depends on microclimate, with temperature and rainfall being major drivers. In complex terrain the fine-scale variation in microclimate (and hence water availability) as a result of slope orientation is caused by differences in incoming radiation and surface temperature. Aridity, measured as the long-term balance between net radiation and rainfall, is a metric that can be used to represent variations in water availability within the landscape. Since aridity metrics can be obtained at fine spatial scales, they could theoretically be used to investigate how decomposition processes vary across complex landscapes. In this study, four research sites were selected in tall open sclerophyll forest along a aridity gradient (Budyko dryness index ranging from 1.56 -2.22) where microclimate, litter moisture and soil moisture were monitored continuously for one year. Litter bags were packed to estimate decomposition rates (k) using leaves of a tree species not present in the study area (Eucalyptus globulus) in order to avoid home-field advantage effects. Litter mass loss was measured to assess the activity of macro-decomposers (6mm litter bag mesh size), meso-decomposers (1 mm mesh), microbes above-ground (0.2 mm mesh) and microbes below-ground (2 cm depth, 0.2 mm mesh). Four replicates for each set of bags were installed at each site and bags were collected at 1, 2, 4, 7 and 12 months since installation. We first tested whether differences in microclimate due to slope orientation have significant effects on decomposition processes. Then the dryness index was related to decomposition rates to evaluate if small-scale variation in decomposition can be predicted using readily available information on rainfall and radiation. Decomposition rates (k), calculated fitting single pool negative exponential models, generally decreased with increasing aridity with k going from 0.0025 day-1 on equatorial (dry) facing slopes to 0.0040 day-1 on polar (wet) facing slopes. However, differences in temperature as a result of morning vs afternoon sun on east and west aspects, respectively, (not captured in the aridity metric) resulted in poor prediction of decomposition for the sites located in the intermediate aridity range. Overall the results highlight that relatively small differences in microclimate due to slope orientation can have large effects on decomposition. Future research will aim to refine the aridity metric to better resolve small scale variation in surface temperature which is important when up-scaling decomposition processes to landscapes.
Provisioning cooling elements for chillerless data centers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chainer, Timothy J.; Parida, Pritish R.
Systems and methods for cooling include one or more computing structure, an inter-structure liquid cooling system that includes valves configured to selectively provide liquid coolant to the one or more computing structures; a heat rejection system that includes one or more heat rejection units configured to cool liquid coolant; and one or more liquid-to-liquid heat exchangers that include valves configured to selectively transfer heat from liquid coolant in the inter-structure liquid cooling system to liquid coolant in the heat rejection system. Each computing structure further includes one or more liquid-cooled servers; and an intra-structure liquid cooling system that has valvesmore » configured to selectively provide liquid coolant to the one or more liquid-cooled servers.« less
Performance characteristic of hybrid cooling system based on cooling pad and evaporator
NASA Astrophysics Data System (ADS)
Yoon, J. I.; Son, C. H.; Choi, K. H.; Kim, Y. B.; Sung, Y. H.; Roh, S. J.; Kim, Y. M.; Seol, S. H.
2018-01-01
In South Korea, most of domestic animals such as pigs and chickens might die due to thermal diseases if they are exposed to the high temperature consistently. In order to save them from the heat wave, numerous efforts have been carried out: installing a shade net, adjusting time of feeding, spraying mist and setting up a circulation fan. However, these methods have not shown significant improvements. Thus, this study proposes a hybrid cooling system combining evaporative cooler and air-conditioner in order to resolve the conventional problems caused by the high temperature in the livestock industry. The problem of cooling systems using evaporative cooling pads is that they are not effective for eliminating huge heat load due to their limited capacity. And, temperature of the supplied air cannot be low enough compared to conventional air-conditioning systems. On the other hand, conventional air-conditioning systems require relatively expensive installation cost, and high operating cost compared to evaporative cooling system. The hybrid cooling system makes up for the lack of cooling capacity of the evaporative cooler by employing the conventional air-conditioner. Additionally, temperature of supplied air can be lowered enough. In the hybrid cooling system, induced air by a fan is cooled by the evaporation of water in the cooling pad, and it is cooled again by an evaporator in the air-conditioner. Therefore, the more economical operation is possible due to additionally obtained cooling capacity from the cooling pads. Major results of experimental analysis of hybrid cooling system are as follows. The compressor power consumption of the hybrid cooling system is about 23% lower, and its COP is 17% higher than that of the conventional air-conditioners. Regarding the condition of changing ambient temperature, the total power consumption decreased by about 5% as the ambient temperature changed from 28.7°C to 31.7°C. Cooling capacity and COP also presented about 3% and 1% of minor difference at the same comparison condition.
Zhai, Haibo; Rubin, Edward S
2016-04-05
Advanced cooling systems can be deployed to enhance the resilience of thermoelectric power generation systems. This study developed and applied a new power plant modeling option for a hybrid cooling system at coal- or natural-gas-fired power plants with and without amine-based carbon capture and storage (CCS) systems. The results of the plant-level analyses show that the performance and cost of hybrid cooling systems are affected by a range of environmental, technical, and economic parameters. In general, when hot periods last the entire summer, the wet unit of a hybrid cooling system needs to share about 30% of the total plant cooling load in order to minimize the overall system cost. CCS deployment can lead to a significant increase in the water use of hybrid cooling systems, depending on the level of CO2 capture. Compared to wet cooling systems, widespread applications of hybrid cooling systems can substantially reduce water use in the electric power sector with only a moderate increase in the plant-level cost of electricity generation.
Solar-Cooled Hotel in the Virgin Islands
NASA Technical Reports Server (NTRS)
Harber, H.
1982-01-01
Performance of solar cooling system is described in 21-page report. System provides cooling for public areas including ball rooms, restaurant, lounge, lobby and shops. Chilled water from solar-cooling system is also used to cool hot water from hotel's desalinization plant.
ERIC Educational Resources Information Center
Fisher, Carol J.
1978-01-01
Presents ideas and activities for teaching basic skills including vocabulary building, learning science from the microclimates, using tape recorders to teach reading, and using monsters to teach metrics. (JMB)
NASA Astrophysics Data System (ADS)
Pospelova, I.
2017-11-01
The article suggests an original way of keeping heat load and its compensation for a microclimate system by proposing the “Smart Wall”. The construction consists of specially combined composite materials including phase-transition materials. The method for determination of the layer thickness is proposed for a certain accumulation time. Varying the thickness and composition of the layer it is possible to achieve a low amount of the thermal conductivity coefficient and to obtain various functional characteristics of fences.
Low pressure cooling seal system for a gas turbine engine
Marra, John J
2014-04-01
A low pressure cooling system for a turbine engine for directing cooling fluids at low pressure, such as at ambient pressure, through at least one cooling fluid supply channel and into a cooling fluid mixing chamber positioned immediately downstream from a row of turbine blades extending radially outward from a rotor assembly to prevent ingestion of hot gases into internal aspects of the rotor assembly. The low pressure cooling system may also include at least one bleed channel that may extend through the rotor assembly and exhaust cooling fluids into the cooling fluid mixing chamber to seal a gap between rotational turbine blades and a downstream, stationary turbine component. Use of ambient pressure cooling fluids by the low pressure cooling system results in tremendous efficiencies by eliminating the need for pressurized cooling fluids for sealing this gap.
Microclimates of l'Aven d'Orgnac and other French limestone caves (Chauvet, Esparros, Marsoulas)
NASA Astrophysics Data System (ADS)
Bourges, F.; Genthon, P.; Mangin, A.; D'Hulst, D.
2006-10-01
We assess the aerodynamics of the atmosphere in some limestone caves using a 5-year monitoring of the Aven d'Orgnac system, shorter thermal vertical profiling experiments, and comparison with the time series from other French caves. In the first rooms, located under the Aven opening, our records indicate, for each year, a succession of a summer regime characterized by stable parameters (except for the perturbations introduced by tourist visits) and a winter regime, in which the inner air temperature drops and is highly correlated with that outside. Atmospheric composition suggests that during the winter regime the cave is ventilated by the outside air. We show that the onset of the winter regime is governed by a thermo-convective instability involving the inflow of the outside cold and dense air. Atmospheric temperature and composition allow us to follow the stepwise progression of the winter regime toward the adjacent rooms.In the Salle Plane (SP), a far room of the Orgnac-Issirac karstic system, in which the winter regime has never been observed, the air temperature is extremely homogeneous and steady, and is characterized by a half-daily signal of amplitude less than 0.03 °C, which is correlated with the derivative of pressure versus time. This correlation, which is also observed in various other confined caves, may be explained by pressure-induced temperature changes relaxed in less than 1 h by thermal exchanges with a large volume of rock whose temperature is assumed to be constant.The various microclimates of karstic cave systems should be taken into account for the conservation of the caves open to tourists and for the interpretation of growth laminae of speleothems.
Turbine airfoil with ambient cooling system
Campbell, Jr, Christian X.; Marra, John J.; Marsh, Jan H.
2016-06-07
A turbine airfoil usable in a turbine engine and having at least one ambient air cooling system is disclosed. At least a portion of the cooling system may include one or more cooling channels configured to receive ambient air at about atmospheric pressure. The ambient air cooling system may have a tip static pressure to ambient pressure ratio of at least 0.5, and in at least one embodiment, may include a tip static pressure to ambient pressure ratio of between about 0.5 and about 3.0. The cooling system may also be configured such that an under root slot chamber in the root is large to minimize supply air velocity. One or more cooling channels of the ambient air cooling system may terminate at an outlet at the tip such that the outlet is aligned with inner surfaces forming the at least one cooling channel in the airfoil to facilitate high mass flow.
A dew point signaller for conservation of works of art.
Camuffo, D; Valcher, S
1986-03-01
All works of art, from paintings, frescoes, sculptures, to monuments and buildings, are affected by diurnal and seasonal variations of the local microclimate, which induce interactions with the environmental atmosphere. Heat and vapour exchanges cause fluxes of heat and mass between the surface and the atmosphere, and may favour the agressivity of environmental pollutants. Condensation-evaporation cycles are recognized as being very important processes which adversely affect the life-time of the work of art. The need to control the microclimate or to stop condensation processes has been resolved by means of a dew-point signaller especially designed to overcome this problem. This paper discusses the characteristics of this device as well as the environmental philosophy which should be followed when conserving works of art.
THE COOLING REQUIREMENTS AND PROCESS SYSTEMS OF THE SOUTH AFRICAN RESEARCH REACTOR, SAFARI 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Colley, J.R.
1962-12-01
The SAFARI 1 research reactor is cooled and moderated by light water. There are three process systems, a primary water system which cools the reactor core and surroundings, a pool water system, and a secondary water system which removes the heat from the primary and pool systems. The cooling requirements for the reactor core and experimental facilities are outlined, and the cooling and purification functions of the three process systems are described. (auth)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chainer, Timothy J.; Parida, Pritish R.
Systems and methods for cooling include one or more computing structure, an inter-structure liquid cooling system that includes valves configured to selectively provide liquid coolant to the one or more computing structures; a heat rejection system that includes one or more heat rejection units configured to cool liquid coolant; and one or more liquid-to-liquid heat exchangers that include valves configured to selectively transfer heat from liquid coolant in the inter-structure liquid cooling system to liquid coolant in the heat rejection system. Each computing structure further includes one or more liquid-cooled servers; and an intra-structure liquid cooling system that has valvesmore » configured to selectively provide liquid coolant to the one or more liquid-cooled servers.« less
Performance of the dark energy camera liquid nitrogen cooling system
NASA Astrophysics Data System (ADS)
Cease, H.; Alvarez, M.; Alvarez, R.; Bonati, M.; Derylo, G.; Estrada, J.; Flaugher, B.; Flores, R.; Lathrop, A.; Munoz, F.; Schmidt, R.; Schmitt, R. L.; Schultz, K.; Kuhlmann, S.; Zhao, A.
2014-01-01
The Dark Energy Camera, the Imager and its cooling system was installed onto the Blanco 4m telescope at the Cerro Tololo Inter-American Observatory in Chile in September 2012. The imager cooling system is a LN2 two-phase closed loop cryogenic cooling system. The cryogenic circulation processing is located off the telescope. Liquid nitrogen vacuum jacketed transfer lines are run up the outside of the telescope truss tubes to the imager inside the prime focus cage. The design of the cooling system along with commissioning experiences and initial cooling system performance is described. The LN2 cooling system with the DES imager was initially operated at Fermilab for testing, then shipped and tested in the Blanco Coudé room. Now the imager is operating inside the prime focus cage. It is shown that the cooling performance sufficiently cools the imager in a closed loop mode, which can operate for extended time periods without maintenance or LN2 fills.
Increasing the Efficiency of a Thermoelectric Generator Using an Evaporative Cooling System
NASA Astrophysics Data System (ADS)
Boonyasri, M.; Jamradloedluk, J.; Lertsatitthanakorn, C.; Therdyothin, A.; Soponronnarit, S.
2017-05-01
A system for reducing heat from the cold side of a thermoelectric (TE) power generator, based on the principle of evaporative cooling, is presented. An evaporative cooling system could increase the conversion efficiency of a TE generator. To this end, two sets of TE generators were constructed. Both TE generators were composed of five TE power modules. The cold and hot sides of the TE modules were fixed to rectangular fin heat sinks. The hot side heat sinks were inserted in a hot gas duct. The cold side of one set was cooled by the cooling air from a counter flow evaporative cooling system, whereas the other set was cooled by the parallel flow evaporative cooling system. The counter flow pattern had better performance than the parallel flow pattern. A comparison between the TE generator with and without an evaporative cooling system was made. Experimental results show that the power output increased by using the evaporative cooling system. This can significantly increase the TE conversion efficiency. The evaporative cooling system increased the power output of the TE generator from 22.9 W of ambient air flowing through the heat sinks to 28.6 W at the hot gas temperature of 350°C (an increase of about 24.8%). The present study shows the promising potential of using TE generators with evaporative cooling for waste heat recovery.
NASA Technical Reports Server (NTRS)
Stone, J. E.
1975-01-01
The effects of fuselage cross section and structural arrangement on the performance of actively cooled hypersonic cruise vehicles are investigated. An active cooling system which maintains the aircraft's entire surface area at temperatures below 394 K at Mach 6 is developed along with a hydrogen fuel tankage thermal protection system. Thermodynamic characteristics of the actively cooled thermal protection systems established are summarized. Design heat loads and coolant flowrate requirements are defined for each major structural section and for the total system. Cooling system weights are summarized at the major component level. Conclusions and recommendations are included.
Analysis of hybrid interface cooling system using air ventilation and nanofluid
NASA Astrophysics Data System (ADS)
Rani, M. F. H.; Razlan, Z. M.; Bakar, S. A.; Desa, H.; Wan, W. K.; Ibrahim, I.; Kamarrudin, N. S.; Bin-Abdun, Nazih A.
2017-09-01
The hybrid interface cooling system needs to be designed for maintaining the electric vehicle's battery cell temperature at 25°C. The hybrid interface cooling system is a combination of two individual systems, where the primary cooling system (R-134a) and the secondary cooling system (CuO + Water) will be used to absorb the heat generated by the battery cells. The ventilation system is designed using air as the medium to transfer the heat from the batteries to the refrigeration system (R-134a). Research will focus on determining the suitable compressor displacement, the heat exchanger volume and the expansion valve resistance value. The analysis for the secondary cooling system is focused on the cooling coil where low temperature nanofluid is passing through each interval of the battery cells. For analysing purposes, the thermal properties of the mixture of 50 grams, Copper (II) Oxide and the base fluid have been determined. The hybrid interface cooling system are able to achieve 57.82% increments in term of rate of heat transfer as compared to the individual refrigeration system.
ERIC Educational Resources Information Center
Minnesota State Dept. of Education, St. Paul. Div. of Vocational and Technical Education.
THIS MODULE OF A 30-MODULE COURSE IS DESIGNED TO DEVELOP AN UNDERSTANDING OF THE OPERATION AND MAINTENANCE OF THE DIESEL ENGINE COOLING SYSTEM AND TO PROVIDE A DESCRIPTION OF HEAVY TIRES AND WHEELS USED ON DIESEL POWERED VEHICLES. TOPICS ARE (1) THEORY OF THE COOLING SYSTEM, (2) COOLING SYSTEM COMPONENTS, (3) MAINTENANCE TIPS (COOLING SYSTEM), (4)…
Turbine airfoil with an internal cooling system having vortex forming turbulators
Lee, Ching-Pang
2014-12-30
A turbine airfoil usable in a turbine engine and having at least one cooling system is disclosed. At least a portion of the cooling system may include one or more cooling channels having a plurality of turbulators protruding from an inner surface and positioned generally nonorthogonal and nonparallel to a longitudinal axis of the airfoil cooling channel. The configuration of turbulators may create a higher internal convective cooling potential for the blade cooling passage, thereby generating a high rate of internal convective heat transfer and attendant improvement in overall cooling performance. This translates into a reduction in cooling fluid demand and better turbine performance.
Hydronic radiant cooling: Overview and preliminary performance assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feustel, H.E.
1993-05-01
A significant amount of electrical energy used to cool non-residential buildings is drawn by the fans used to transport the cool air through the thermal distribution system. Hydronic systems reduce the amount of air transported through the building by separating ventilation and thermal conditioning. Due to the physical properties of water, hydronic distribution systems can transport a given amount of thermal energy using less than 5% of the otherwise necessary fan energy. This savings alone significantly reduces the energy consumption and especially the peak power requirement This survey clearly shows advantages for radiant cooling in combination with hydronic thermal distributionmore » systems in comparison with the All-Air Systems commonly used in California. The report describes a literature survey on the system`s development, thermal comfort issues, and cooling performance. The cooling power potential and the cooling power requirement are investigated for several California climates. Peak-power requirement is compared for hydronic radiant cooling and conventional All-Air-Systems.« less
Functions of perch relocations in a communal night roost of wintering bald eagles
Yackel Adams, A.A.; Skagen, S.K.; Knight, R.L.
2000-01-01
We investigated the functions of perch relocations within a communal night roost of wintering bald eagles (Haliaeetus leucocephalus) along the Nooksack River, Washington, during two winters. We tested seven predictions of two nonexclusive hypotheses: (1) bald eagles relocate within roosts to assess foraging success of conspecifics and (2) bald eagles relocate to obtain thermoregulatory benefits from an improved microclimate. Additionally, we gathered descriptive information to allow refinement of further alternative hypotheses. We rejected the hypothesis that relocations are a means of assessing foraging success. Contrary to our expectations, immature eagles did not relocate to be closer to adults, and relocations were less frequent when food was less abundant. Our data support the hypothesis that eagles relocate within night roosts to obtain a favorable microclimate during winters when they are subjected to cold stress and food stress. In both winters, relocations were more frequent in the evening than in the morning. In both winters, most evening relocations were to the center of the roost rather than to its edge, and the frequency of relocation to the center was greater when temperatures were low. The microclimate hypothesis, however, explains only a limited number of relocations. Based on our findings, it is likely that relocation has multiple functions, including establishing and (or) maintaining foraging associations, establishing and (or) maintaining social-dominance hierarchies when food is less abundant, and nonsocial activities.
Lozano, Yudi M; Armas, Cristina; Hortal, Sara; Casanoves, Fernando; Pugnaire, Francisco I
2017-12-01
Nurse plants promote establishment of other plant species by buffering climate extremes and improving soil properties. Soil biota plays an important role, but an analysis to disentangle the effects of soil microorganisms, soil properties and microclimate on facilitation is lacking. In three microhabitats (gaps, small and large Retama shrubs), we placed six microcosms with sterilized soil, two per soil origin (i.e. from each microhabitat). One in every pair received an alive, and the other a sterile, inoculum from its own soil. Seeds of annual plants were sown into the microcosms. Germination, survival and biomass were monitored. Soil bacterial communities were characterized by pyrosequencing. Germination in living Retama inoculum was nearly double that of germination in sterile inoculum. Germination was greater under Retama canopies than in gaps. Biomass was up to three times higher in nurse than in gap soils. Soil microorganisms, soil properties and microclimate showed a range of positive to negative effects on understory plants depending on species identity and life stage. Nurse soil microorganisms promoted germination, but the effect was smaller than the positive effects of soil properties and microclimate under nurses. Nurse below-ground environment (soil properties and microorganisms) promoted plant growth and survival more than nurse microhabitat. © 2017 The Authors. New Phytologist © 2017 New Phytologist Trust.
Diffusive and subdiffusive dynamics of indoor microclimate: a time series modeling.
Maciejewska, Monika; Szczurek, Andrzej; Sikora, Grzegorz; Wyłomańska, Agnieszka
2012-09-01
The indoor microclimate is an issue in modern society, where people spend about 90% of their time indoors. Temperature and relative humidity are commonly used for its evaluation. In this context, the two parameters are usually considered as behaving in the same manner, just inversely correlated. This opinion comes from observation of the deterministic components of temperature and humidity time series. We focus on the dynamics and the dependency structure of the time series of these parameters, without deterministic components. Here we apply the mean square displacement, the autoregressive integrated moving average (ARIMA), and the methodology for studying anomalous diffusion. The analyzed data originated from five monitoring locations inside a modern office building, covering a period of nearly one week. It was found that the temperature data exhibited a transition between diffusive and subdiffusive behavior, when the building occupancy pattern changed from the weekday to the weekend pattern. At the same time the relative humidity consistently showed diffusive character. Also the structures of the dependencies of the temperature and humidity data sets were different, as shown by the different structures of the ARIMA models which were found appropriate. In the space domain, the dynamics and dependency structure of the particular parameter were preserved. This work proposes an approach to describe the very complex conditions of indoor air and it contributes to the improvement of the representative character of microclimate monitoring.
Small Heat Shock Protein Responses Differ between Chaparral Shrubs from Contrasting Microclimates
Knight, Charles A.
2010-01-01
Smore » mall heat shock protein (sHsp) responses were studied for two evergreen perennial shrubs in the northern California chaparral; one common on warm, south-facing slopes ( Ceanothus cuneatus ), and the other on cooler, north-facing slopes ( Prunus ilicifolia ). mall Hsp expression was induced experimentally for field collected leaves. Leaf collections were made where the species co-occur. mall Hsp expression was quantified using two antibodies, one specific to a chloroplast 22 kD sHsp and another that detects a broad range of sHsps. Differences between chloroplast sHsp accumulation, which protects thermally labile proteins in PII, and the general sHsp response were examined. The species from the cooler microclimate, Prunus , had a lower induction temperature and accumulated greater levels of sHsps at low temperatures. Both Prunus and Ceanothus reached peak sHsp expression at 42 ∘ C . The species from the warmer microclimate, Ceanothus , had greater sHsp expression at higher temperatures. Chloroplast sHsp expression generally tracked sHsp expression in Ceanothus , but in Prunus general Hsps were elevated before chloroplast sHsps. Variation between species for sHsp expression (induction temperatures, accumulation levels, and the duration of expression) coupled with the costs of Hsp synthesis, may contribute to differences in the abundance and distribution of plants across environmental gradients.« less
Cooling Tests of an Airplane Equipped with an NACA Cowling and a Wing-duct Cooling System
NASA Technical Reports Server (NTRS)
Turner, L I , Jr; Bierman, David; Boothy, W B
1941-01-01
Cooling tests were made of a Northrop A-17A attack airplane successively equipped with a conventional.NACA cowling and with a wing-duct cooling system. The method of cooling the engine by admitting air from the propeller slipstream into wing ducts, passing it first through the accessory compartment and then over the engine from rear to front, appeared to offer possibilities for improved engine cooling, increased cooling of the accessories, and better fairing of the power-plant installation. The results showed that ground cooling for the wing duct system without cowl flap was better than for the NACA cowling with flap; ground cooling was appreciably improved by installing a cowl flap. Satisfactory temperatures were maintained in both climb and high-speed flight, but, with the use of conventional baffles, a greater quantity of cooling air appeared to be required for the wing duct system.
Revisiting the Cooling Flow Problem in Galaxies, Groups, and Clusters of Galaxies
NASA Astrophysics Data System (ADS)
McDonald, M.; Gaspari, M.; McNamara, B. R.; Tremblay, G. R.
2018-05-01
We present a study of 107 galaxies, groups, and clusters spanning ∼3 orders of magnitude in mass, ∼5 orders of magnitude in central galaxy star formation rate (SFR), ∼4 orders of magnitude in the classical cooling rate ({\\dot{M}}cool}\\equiv {M}gas}(r< {r}cool})/{t}cool}) of the intracluster medium (ICM), and ∼5 orders of magnitude in the central black hole accretion rate. For each system in this sample, we measure the ICM cooling rate, {\\dot{M}}cool}, using archival Chandra X-ray data and acquire the SFR and systematic uncertainty in the SFR by combining over 330 estimates from dozens of literature sources. With these data, we estimate the efficiency with which the ICM cools and forms stars, finding {ε }cool}\\equiv {SFR}/{\\dot{M}}cool}=1.4 % +/- 0.4% for systems with {\\dot{M}}cool}> 30 M ⊙ yr‑1. For these systems, we measure a slope in the SFR–{\\dot{M}}cool} relation greater than unity, suggesting that the systems with the strongest cool cores are also cooling more efficiently. We propose that this may be related to, on average, higher black hole accretion rates in the strongest cool cores, which could influence the total amount (saturating near the Eddington rate) and dominant mode (mechanical versus radiative) of feedback. For systems with {\\dot{M}}cool}< 30 M ⊙ yr‑1, we find that the SFR and {\\dot{M}}cool} are uncorrelated and show that this is consistent with star formation being fueled at a low (but dominant) level by recycled ISM gas in these systems. We find an intrinsic log-normal scatter in SFR at a fixed {\\dot{M}}cool} of 0.52 ± 0.06 dex (1σ rms), suggesting that cooling is tightly self-regulated over very long timescales but can vary dramatically on short timescales. There is weak evidence that this scatter may be related to the feedback mechanism, with the scatter being minimized (∼0.4 dex) for systems for which the mechanical feedback power is within a factor of two of the cooling luminosity.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None,
1981-09-01
Ninety-three project summaries are presented which discuss the following aspects of active solar heating and cooling: Rankine solar cooling systems; absorption solar cooling systems; desiccant solar cooling systems; solar heat pump systems; solar hot water systems; special projects (such as the National Solar Data Network, hybrid solar thermal/photovoltaic applications, and heat transfer and water migration in soils); administrative/management support; and solar collector, storage, controls, analysis, and materials technology. (LEW)
Influence of Microclimate on Semi-Arid Montane Conifer Forest Sapflux Velocity in Complex Terrain
NASA Astrophysics Data System (ADS)
Thirouin, K. R.; Barnard, D. M.; Barnard, H. R.
2016-12-01
Microclimate variation in complex terrain is key to our understanding of large-scale climate change effects on montane ecosystems. Modern climate models forecast that semi-arid montane ecosystems in the western United States are to experience increases in temperature, number of extreme drought events, and decreases in annual snowpack, all of which will potentially influence ecosystem water, carbon, and energy balances. In this study, we developed response curves that describe the relationships between stem sapflux velocity, air temperature (Tair), incoming solar radiation (SWin), soil temperature (Tsoil), and soil moisture content (VWC) in sites of Pinus contorta and Pinus ponderosa distributed along an elevation and aspect gradient in the montane zone of the Central Rocky Mountains, Colorado, USA. Among sites we found sapflux velocity to be significantly correlated with all four environmental factors (p < 0.05), but most strongly with SWin and Tair. The response of sapflux velocity to SWin was logarithmic, whereas the response to Tair indicated a peak sapflux velocity at a site-specific temperature that declined with increasing Tair. Sapflux velocity also increased with increasing VWC, but decreased with increasing Tsoil. At south-facing sites, the initial increase in the logarithmic response curve for SWin leveled off at 150-250 W m-2, whereas for north-facing sites it leveled off at 50-125 W m-2. While the differences in the SWin response between aspects could be due to species physiological differences, the highest elevation south-facing P. contorta site behaved similarly to the south-facing P. ponderosa, suggesting that environmental drivers may dominate the response. In response to Tair, peak sapflux velocity occurred at 12-13 degrees C at all sites except the mid-slope north-facing P. contorta site, which also had the lowest Tsoil. The responses of stem sapflux velocity to climate drivers indicate that forest transpiration is regulated by microclimate gradients across small spatial scales in complex terrain, which need to be characterized in order to understand broader ecosystem dynamics and the role that large-scale climate change will play in these systems.
40 CFR 90.307 - Engine cooling system.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Engine cooling system. 90.307 Section...) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Emission Test Equipment Provisions § 90.307 Engine cooling system. An engine cooling system is required with sufficient capacity to...
40 CFR 90.307 - Engine cooling system.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Engine cooling system. 90.307 Section...) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Emission Test Equipment Provisions § 90.307 Engine cooling system. An engine cooling system is required with sufficient capacity to...
40 CFR 89.329 - Engine cooling system.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 21 2012-07-01 2012-07-01 false Engine cooling system. 89.329 Section...) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Emission Test Equipment Provisions § 89.329 Engine cooling system. An engine cooling system is required with sufficient capacity to...
40 CFR 91.307 - Engine cooling system.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Engine cooling system. 91.307 Section...) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Emission Test Equipment Provisions § 91.307 Engine cooling system. An engine cooling system is required with sufficient capacity to maintain the engine at...
40 CFR 89.329 - Engine cooling system.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Engine cooling system. 89.329 Section...) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Emission Test Equipment Provisions § 89.329 Engine cooling system. An engine cooling system is required with sufficient capacity to...
40 CFR 89.329 - Engine cooling system.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 20 2014-07-01 2013-07-01 true Engine cooling system. 89.329 Section...) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Emission Test Equipment Provisions § 89.329 Engine cooling system. An engine cooling system is required with sufficient capacity to...
40 CFR 91.307 - Engine cooling system.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Engine cooling system. 91.307 Section...) CONTROL OF EMISSIONS FROM MARINE SPARK-IGNITION ENGINES Emission Test Equipment Provisions § 91.307 Engine cooling system. An engine cooling system is required with sufficient capacity to maintain the engine at...
40 CFR 90.307 - Engine cooling system.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 21 2013-07-01 2013-07-01 false Engine cooling system. 90.307 Section...) CONTROL OF EMISSIONS FROM NONROAD SPARK-IGNITION ENGINES AT OR BELOW 19 KILOWATTS Emission Test Equipment Provisions § 90.307 Engine cooling system. An engine cooling system is required with sufficient capacity to...
40 CFR 89.329 - Engine cooling system.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Engine cooling system. 89.329 Section...) CONTROL OF EMISSIONS FROM NEW AND IN-USE NONROAD COMPRESSION-IGNITION ENGINES Emission Test Equipment Provisions § 89.329 Engine cooling system. An engine cooling system is required with sufficient capacity to...
Hydronic radiant cooling: Overview and preliminary performance assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feustel, H.E.
1993-05-01
A significant amount of electrical energy used to cool non-residential buildings is drawn by the fans used to transport the cool air through the thermal distribution system. Hydronic systems reduce the amount of air transported through the building by separating ventilation and thermal conditioning. Due to the physical properties of water, hydronic distribution systems can transport a given amount of thermal energy using less than 5% of the otherwise necessary fan energy. This savings alone significantly reduces the energy consumption and especially the peak power requirement This survey clearly shows advantages for radiant cooling in combination with hydronic thermal distributionmore » systems in comparison with the All-Air Systems commonly used in California. The report describes a literature survey on the system's development, thermal comfort issues, and cooling performance. The cooling power potential and the cooling power requirement are investigated for several California climates. Peak-power requirement is compared for hydronic radiant cooling and conventional All-Air-Systems.« less
Passive cooling safety system for liquid metal cooled nuclear reactors
Hunsbedt, Anstein; Boardman, Charles E.; Hui, Marvin M.; Berglund, Robert C.
1991-01-01
A liquid metal cooled nuclear reactor having a passive cooling system for removing residual heat resulting from fuel decay during reactor shutdown. The passive cooling system comprises a plurality of partitions surrounding the reactor vessel in spaced apart relation forming intermediate areas for circulating heat transferring fluid which remove and carry away heat from the reactor vessel. The passive cooling system includes a closed primary fluid circuit through the partitions surrounding the reactor vessel and a partially adjoining secondary open fluid circuit for carrying transferred heat out into the atmosphere.
Indirect passive cooling system for liquid metal cooled nuclear reactors
Hunsbedt, Anstein; Boardman, Charles E.
1990-01-01
A liquid metal cooled nuclear reactor having a passive cooling system for removing residual heat resulting from fuel decay during reactor shutdown. The passive cooling system comprises a plurality of partitions surrounding the reactor vessel in spaced apart relation forming intermediate areas for circulating heat transferring fluid which remove and carry away heat from the reactor vessel. The passive cooling system includes a closed primary fluid circuit through the partitions surrounding the reactor vessel and a partially adjoining secondary open fluid circuit for carrying transferred heat out into the atmosphere.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Herman, R.; O’Brien, S.
Using our own prototype sensor arrays that were deployed to collect microclimate data, we were able to visualize distinct differences in temperature, wind speed, and humidity over very small ranges of distance. We collected data across four polygons within the Barrow Environmental Observatory site. Our prototype microclimate arrays were based on an Arduino microcontroller, DS18B20 temperature sensors, DHT11 relative humidity/temperature sensors, and Vernier anemometers. Data were obtained in a small grid pattern with four sensors spaced 60 cm apart along the x-axis, and moved at 60 cm increments along a y-line across a polygon. Overlaying bird nest location with suchmore » data has allowed us to better answer our research question, “How do Arctic birds choose where to nest to maximize fitness in harsh Arctic environments?”« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Dafen; Jiang, Jiuchun; Kim, Gi-Heon
Choosing a proper cooling method for a lithium-ion (Li-ion) battery pack for electric drive vehicles (EDVs) and making an optimal cooling control strategy to keep the temperature at a optimal range of 15 degrees C to 35 degrees C is essential to increasing safety, extending the pack service life, and reducing costs. When choosing a cooling method and developing strategies, trade-offs need to be made among many facets such as costs, complexity, weight, cooling effects, temperature uniformity, and parasitic power. This paper considers four cell-cooling methods: air cooling, direct liquid cooling, indirect liquid cooling, and fin cooling. To evaluate theirmore » effectiveness, these methods are assessed using a typical large capacity Li-ion pouch cell designed for EDVs from the perspective of coolant parasitic power consumption, maximum temperature rise, temperature difference in a cell, and additional weight used for the cooling system. We use a state-of-the-art Li-ion battery electro-chemical thermal model. The results show that under our assumption an air-cooling system needs 2 to 3 more energy than other methods to keep the same average temperature; an indirect liquid cooling system has the lowest maximum temperature rise; and a fin cooling system adds about 40% extra weight of cell, which weighs most, when the four kinds cooling methods have the same volume. Indirect liquid cooling is a more practical form than direct liquid cooling though it has slightly lower cooling performance.« less
Cooling Performance Analysis of ThePrimary Cooling System ReactorTRIGA-2000Bandung
NASA Astrophysics Data System (ADS)
Irianto, I. D.; Dibyo, S.; Bakhri, S.; Sunaryo, G. R.
2018-02-01
The conversion of reactor fuel type will affect the heat transfer process resulting from the reactor core to the cooling system. This conversion resulted in changes to the cooling system performance and parameters of operation and design of key components of the reactor coolant system, especially the primary cooling system. The calculation of the operating parameters of the primary cooling system of the reactor TRIGA 2000 Bandung is done using ChemCad Package 6.1.4. The calculation of the operating parameters of the cooling system is based on mass and energy balance in each coolant flow path and unit components. Output calculation is the temperature, pressure and flow rate of the coolant used in the cooling process. The results of a simulation of the performance of the primary cooling system indicate that if the primary cooling system operates with a single pump or coolant mass flow rate of 60 kg/s, it will obtain the reactor inlet and outlet temperature respectively 32.2 °C and 40.2 °C. But if it operates with two pumps with a capacity of 75% or coolant mass flow rate of 90 kg/s, the obtained reactor inlet, and outlet temperature respectively 32.9 °C and 38.2 °C. Both models are qualified as a primary coolant for the primary coolant temperature is still below the permitted limit is 49.0 °C.
Vasey, Michael C; Loik, Michael E; Parker, V Thomas
2012-10-01
Mediterranean-type climate (MTC) regions around the world are notable for cool, wet winters and hot, dry summers. A dominant vegetation type in all five MTC regions is evergreen, sclerophyllous shrubland, called chaparral in California. The extreme summer dry season in California is moderated by a persistent low-elevation layer of marine fog and cloud cover along the margin of the Pacific coast. We tested whether late dry season water potentials (Ψ(min)) of chaparral shrubs, such as Arctostaphylos species in central California, are influenced by this coast-to-interior climate gradient. Lowland coastal (maritime) shrubs were found to have significantly less negative Ψ(min) than upland interior shrubs (interior), and stable isotope (δ(13)C) values exhibited greater water use efficiency in the interior. Post-fire resprouter shrubs (resprouters) had significantly less negative Ψ(min) than co-occurring obligate seeder shrubs (seeders) in interior and transitional chaparral, possibly because resprouters have deeper root systems with better access to subsurface water than shallow-rooted seeders. Unexpectedly, maritime resprouters and seeders did not differ significantly in their Ψ(min), possibly reflecting more favorable water availability for shrubs influenced by the summer marine layer. Microclimate and soil data also suggest that maritime habitats have more favorable water availability than the interior. While maritime seeders constitute the majority of local Arctostaphylos endemics, they exhibited significantly greater vulnerability to xylem cavitation than interior seeders. Because rare seeders in maritime chaparral are more vulnerable to xylem cavitation than interior seeders, the potential breakdown of the summer marine layer along the coast is of potential conservation concern.
NASA Astrophysics Data System (ADS)
Zhao, Dongliang
The thermoelectric cooling system has advantages over conventional vapor compression cooling devices, including compact in size, light in weight, high reliability, no mechanical moving parts, no refrigerant, being powered by direct current, and easily switching between cooling and heating modes. However, it has been long suffering from its relatively high cost and low energy efficiency, which has restricted its usage to niche applications, such as space missions, portable cooling devices, scientific and medical equipment, where coefficient of performance (COP) is not as important as reliability, energy availability, and quiet operation environment. Enhancement of thermoelectric cooling system performance generally relies on two methods: improving thermoelectric material efficiency and through thermoelectric cooling system thermal design. This research has been focused on the latter one. A prototype thermoelectric cooling system integrated with phase change material (PCM) thermal energy storage unit for space cooling has been developed. The PCM thermal storage unit used for cold storage at night, functions as the thermoelectric cooling system's heat sink during daytime's cooling period and provides relatively lower hot side temperature for the thermoelectric cooling system. The experimental test of the prototype system in a reduced-scale chamber has realized an average cooling COP of 0.87, with the maximum value of 1.22. Another comparison test for efficacy of PCM thermal storage unit shows that 35.3% electrical energy has been saved from using PCM for the thermoelectric cooling system. In general, PCM faces difficulty of poor thermal conductivity at both solid and liquid phases. This system implemented a finned inner tube to increase heat transfer during PCM charging (melting) process that directly impacts thermoelectric system's performance. A simulation tool for the entire system has been developed including mathematical models for a single thermoelectric module, for the thermoelectric cooling unit, for the PCM thermal storage unit, and for the outdoor air-water heat exchanger. When modeling PCM thermal storage unit, the enthalpy method has been adopted. Since natural convection has been observed in experiments playing a key effect on heat transfer in PCM, a staged effective thermal conductivity (ke) concept and modified Rayleigh (Ra) number formula have been developed to better capture natural convection's variable effects during the PCM charging process. Therefore, a modeling-based design procedure for thermoelectric cooling system integrating with PCM has been proposed. A case study has been completed for a model office room to demonstrate the qualitative and quantitative evaluations to the major system components. Results of this research can be extended to other applications in relevant areas. For instance, the proposed PCM thermal storage unit can be applied to integration with water-cooled conventional air-conditioning devices. Instead of using water cooling, a case study of using the proposed PCM unit for a water-cooled air-conditioner shows a COP increase of more than 25.6%.
The optimal operation of cooling tower systems with variable-frequency control
NASA Astrophysics Data System (ADS)
Cao, Yong; Huang, Liqing; Cui, Zhiguo; Liu, Jing
2018-02-01
This study investigates the energy performance of chiller and cooling tower systems integrated with variable-frequency control for cooling tower fans and condenser water pumps. With regard to an example chiller system serving an office building, Chiller and cooling towers models were developed to assess how different variable-frequency control methods of cooling towers fans and condenser water pumps influence the trade-off between the chiller power, pump power and fan power under various operating conditions. The matching relationship between the cooling tower fans frequency and condenser water pumps frequency at optimal energy consumption of the system is introduced to achieve optimum system performance.
Method for passive cooling liquid metal cooled nuclear reactors, and system thereof
Hunsbedt, Anstein; Busboom, Herbert J.
1991-01-01
A liquid metal cooled nuclear reactor having a passive cooling system for removing residual heat resulting from fuel decay during reactor shutdown. The passive cooling system comprises a plurality of partitions surrounding the reactor vessel in spaced apart relation forming intermediate areas for circulating heat transferring fluid which remove and carry away heat from the reactor vessel.
Cities as Water Supply Catchments to deliver microclimate benefits
NASA Astrophysics Data System (ADS)
Beringer, J.; Tapper, N. J.; Coutts, A.; Loughnan, M.
2010-12-01
Urban development extensively modifies the natural hydrology, biodiversity, carbon balance, air quality and climate of the local and regional environment mainly due to increased impervious surface area (roads, pavements, roofs, etc.). Impervious surface are a legacy of urban infrastructure planning based on a ‘drained city’ to minimise flood risk. The result is a modification of the microclimate around buildings and on a city scale results in the Urban Heat Island (UHI) effect where the urban areas are much hotter than the surrounding rural areas. Such heating comes on top of 20th century human induced climate change, namely decreased rainfall and higher temperatures. Drought conditions have triggered water restrictions in many Australian cities that have dramatically reduced ‘irrigation’ in urban areas. Ironically the drying influence from climate change has now been compounded by the drying influence of water restrictions and the efficient removal of stormwater resulting in desert like climates during summer. This will be further exacerbated by the projected increases in hot days, extreme hot days, heat waves, etc. In turn this excessive heating will compromise the health and liveability of urban dwellers. Stormwater is a potential critical resource that could be used to keep water in the landscape to irrigate urban areas to improve urban micro-climates, sustain vegetation and provide other multiple benefits to create more liveable and resilient urban environments. In Australia's major cities, stormwater harvesting has the potential to provide a low cost, low energy, fit-for-purpose source of water to help secure city supplies. Stormwater reuse not only provides a potential mitigation tool for the UHI and global climate change but has multiple benefits to provide resilience such as 1) Improved human thermal comfort to reduce heat related stress and mortality, 2) Healthy and productive vegetation and increased carbon sequestration, 3) Decreased stormwater runoff and reduced infrastructure cost, 4) Improved air quality through deposition, 5) Improved amenity of the landscape and improved water regimes for urban waterways. We present an overview of a major national research program called ‘Cities as Water Supply Catchments' that has been funded by industry stakeholders and all levels of Government across four major cities. The program is aimed at providing a strong evidence base for mainstreaming stormwater harvesting in Australia. This 5-year inter-disciplinary program involves 8 sub-projects including: the design of sustainable stormwater harvesting technologies; new governance, policy mechanisms and servicing models; and an assessment of the micro-climatic benefits of stormwater harvesting and management solutions. We then focus on the ‘green cities and micro-climates sub-project’ that will undertake a combination of observational and modelling approaches to measure, demonstrate, and project the effectiveness of stormwater harvesting and water sensitive urban design as an approach for improving urban micro-climates.
NASA Astrophysics Data System (ADS)
Dominguez, A.; Kleissl, J.; Farhadi, M.; Kim, D.; Liu, W.; Mao, Y.; Nguyen, H. T.; Roshandell, M.; Sankur, M.; Shiga, Y.; Linden, P.; Hodgkiss, W.
2007-12-01
Meteorological conditions have important implications on human activities. They affect human comfort, productivity, and health, and contribute to material wear and tear. The University of California, San Diego (UCSD)'s proximity to the Pacific Ocean places it in a temperate microclimate which has unique advantages and disadvantages for campus water and energy use and air quality. In particular, the daily sea-breezes provide cool, moist, and salt-laden air to campus. For the Decision-Making Using Real-Time Observations for Environmental Sustainability (DEMROES) project a heterogeneous wireless network of monitoring stations is being set up across the UCSD campus and beyond. Conditions to be monitored include temperature, humidity, wind speed and direction, surface temperatures, solar radiation, particulate matter, CO, NO2, rainfall, and soil moisture. Stations are strategically placed on rooftops and lampposts across campus, as well as select off-campus locations and will transmit data over the UCSD 802.11 wireless network. In addition to rooftop and lamppost stations, mobile stations will be deployed via remotely controlled ground and air units, and stations affixed to campus shuttle busses. These mobile stations will allow for greater spatial resolution of the environmental conditions across campus and inter-sensor calibration. The hardware consists of meteorological, hydrological, and air quality sensors connected to (a) commercial Campbell datalogging systems with serial2IP modules and wireless bridges, and (b) sensor and 802.11 boards based on the dpac technology developed in-house. The measurements will serve campus facilities management with information to feed the energy management system (EMS) for building operation and energy conservation, and irrigation management. The technology developed for this project can be applied elsewhere thereby contributing to hydrologic and ecologic observatories. Through extensive student involvement a new generation of environmental scientists and engineers will be trained to work on the planning and execution of national observatories.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhao, Weihuan; France, David M.; Yu, Wenhua
At present, single-phase liquid, forced convection cooled heat sinks with fins are used to cool power electronics in hybrid electric vehicles (HEVs). Although use of fins in the cooling channels increases heat transfer rates considerably, a second low-temperature radiator and associated pumping system are still required in HEVs. This additional cooling system adds weight and cost while decreasing the efficiency of HEVs. With the objective of eliminating this additional low-temperature radiator and pumping system in HEVs, an alternative cooling technology, subcooled boiling in the cooling channels, was investigated in the present study. Numerical heat transfer simulations were performed using subcooledmore » boiling in the power electronics cooling channels with the coolant supplied from the existing main engine cooling system. Results show that this subcooled boiling system is capable of removing 25% more heat from the power electronics than the conventional forced convection cooling technology, or it can reduce the junction temperature of the power electronics at the current heat removal rate. With the 25% increased heat transfer option, high heat fluxes up to 250 W/cm(2) (typical for wideband-gap semiconductor applications) are possible by using the subcooled boiling system.« less
Cooled Water Production System,
The invention refers to the field of air conditioning and regards an apparatus for obtaining cooled water . The purpose of the invention is to develop...such a system for obtaining cooled water which would permit the maximum use of the cooling effect of the water -cooling tower.
Performance Analysis of XCPC Powered Solar Cooling Demonstration Project
NASA Astrophysics Data System (ADS)
Widyolar, Bennett K.
A solar thermal cooling system using novel non-tracking External Compound Parabolic Concentrators (XCPC) has been built at the University of California, Merced and operated for two cooling seasons. Its performance in providing power for space cooling has been analyzed. This solar cooling system is comprised of 53.3 m2 of XCPC trough collectors which are used to power a 23 kW double effect (LiBr) absorption chiller. This is the first system that combines both XCPC and absorption chilling technologies. Performance of the system was measured in both sunny and cloudy conditions, with both clean and dirty collectors. It was found that these collectors are well suited at providing thermal power to drive absorption cooling systems and that both the coinciding of available thermal power with cooling demand and the simplicity of the XCPC collectors compared to other solar thermal collectors makes them a highly attractive candidate for cooling projects.
Environmental monitoring in four European museums
NASA Astrophysics Data System (ADS)
Camuffo, Dario; Van Grieken, Rene; Busse, Hans-Jürgen; Sturaro, Giovanni; Valentino, Antonio; Bernardi, Adriana; Blades, Nigel; Shooter, David; Gysels, Kristin; Deutsch, Felix; Wieser, Monika; Kim, Oliver; Ulrych, Ursula
In a European multidisciplinary research project concerning environmental diagnostics, museums have been selected, having different climate and pollution conditions, i.e.: Correr Museum, Venice (Italy); Kunsthistorisches Museum, Vienna (Austria); Royal Museum of Fine Arts, Antwerp (Belgium); Sainsbury Centre for Visual Arts, Norwich (UK). Some field tests investigated the microclimate, the gaseous and particulate air pollution and the biological contamination to suggest mitigative techniques that may reduce the potential for damage in the long run. Potential risk factors are generated by imbalance in temperature and humidity, generated by heating, air conditioning or ventilating system (HVAC), or the building structures, exchange of outside air, or large visitor numbers. HVAC may also enhance indoor gaseous pollution. Plants and carpets represent potential niches for bacterial colonisation. Pollutants and particles have been recognised having partly external and partly internal origin. Tourism has a direct negative impact, i.e. transport of external particles, release of heat, vapour and CO 2, as well as generation of turbulence, which increases the deposition rate of particulate matter. However, the main problem is that the microclimate has been planned for the well being of visitors during only the visiting time, disregarding the needs of conservation that requires a constant climate by day and by night. In some of these cases, better environmental niches have been obtained with the help of showcases. In other cases, showcases worsened the situation, especially when incandescent lamps were put inside.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Porter, W.P.
1985-08-01
We continue to put considerable effort into analysis of the dynamics of interactions between environmental and animal variance and its implications for growth and reproduction. We have completed the physiological experiments necessary for defining a complete mass and energy budget for two species of lizards, Uta stansburiana, and Sceloporus undulatus. We have completed the programming and are evaluating calculations for potential growth and reproduction for Sceloporus undulatus for the sandhill country of western Nebraska, where we have field data on microclimates, doubly labeled water measurements, and growth and reproduction measurements to do a thorough test of the microclimate and ectothermmore » models that together calculate potential growth and reproduction. The doubly labeled water analysis system is calibrated and running very well. We are just beginning analysis of the lizard samples from Nebraska. In deer mice, marmots and prairie dogs we have found significant diurnal and seasonal changes in body temperature and activity times. Deer mice in the field may exhibit 6-7 degree and as much as 20 degree body temperature changes in 15 to 20 minute intervals. Winter work in Jackson Hole at -40C showed capability for core temperature drops in deer mice of 8C in one minute and full recovery once the animal could burrow into the snow. Our calculations show that this variability saves significantly in energy costs.« less
A dynamic tester to evaluate the thermal and moisture behaviour of the surface of textiles.
Li, Wenbin; Xu, Weilin; Wang, Hao; Wang, Xin
2016-01-01
The thermal and moisture behaviour of the microclimate of textiles is crucial in determining the physiological comfort of apparel, but it has not been investigated sufficiently due to the lack of particular evaluation techniques. Based on sensing, temperature controlling and wireless communicating technology, a specially designed tester has been developed in this study to evaluate the thermal and moisture behaviour of the surface of textiles in moving status. A temperature acquisition system and a temperature controllable hotplate have been established to test temperature and simulate the heat of human body, respectively. Relative humidity of the surface of fabric in the dynamic process has been successfully tested through sensing. Meanwhile, wireless communication technology was applied to transport the acquired data of temperature and humidity to computer for further processing. Continuous power supply was achieved by intensive contact between an elastic copper plate and copper ring on the rotating shaft. This tester provides the platform to evaluate the thermal and moisture behaviour of textiles. It enables users to conduct a dynamic analysis on the temperature and humidity together with the thermal and moisture transport behaviour of the surface of fabric in moving condition. Development of this tester opens the door of investigation on the micro-climate of textiles in real time service, and eventually benefits the understanding of the sensation comfort and wellbeing of apparel wearers. Copyright © 2015 Elsevier Ltd. All rights reserved.
Experiences in solar cooling systems
NASA Astrophysics Data System (ADS)
Ward, D. S.
The results of performance evaluations for nine solar cooling systems are presented, and reasons fow low or high net energy balances are discussed. Six of the nine systems are noted to have performed unfavorably compared to standard cooling systems due to thermal storage losses, excessive system electrical demands, inappropriate control strategies, poor system-to-load matching, and poor chiller performance. A reduction in heat losses in one residential unit increased the total system efficiency by 2.5%, while eliminating heat losses to the building interior increased the efficiency by 3.3%. The best system incorporated a lithium bromide absorption chiller and a Rankine cycle compression unit for a commercial application. Improvements in the cooling tower and fan configurations to increase the solar cooling system efficiency are indicated. Best performances are expected to occur in climates inducing high annual cooling loads.
NASA Astrophysics Data System (ADS)
Tseliou, Areti; Tsiros, Ioannis X.; Nikolopoulou, Marialena
2017-07-01
Outdoor urban areas are very important for cities and microclimate is a critical parameter in the design process, contributing to thermal comfort which is important for urban developments. The research presented in this paper is part of extensive field surveys conducted in Athens aimed at investigating people's thermal sensation in a Mediterranean city. Based on 2313 questionnaires and microclimatic data the current work focuses on the relative frequencies of people's evaluation of the thermal along with the sun and wind sensations between two seasons trying to identify the seasonal differences in thermal sensation. The impact of basic meteorological factors on thermal discomfort with respect to season are also examined, as well as the use of the outdoor environment. Results show that psychological adaptation is an important contributing factor influencing perception of the thermal environment between seasons. In addition, the thermal sensation votes during the cool months show that individuals are satisfied to a great extend with the thermal environment whereas the combination of high air temperature, strong solar radiation and weak wind lead to thermal discomfort during summertime. As far as the appropriate urban design in the Mediterranean climate is concerned, priority should be given to the warm months of the year.
Cooling water distribution system
Orr, Richard
1994-01-01
A passive containment cooling system for a nuclear reactor containment vessel. Disclosed is a cooling water distribution system for introducing cooling water by gravity uniformly over the outer surface of a steel containment vessel using an interconnected series of radial guide elements, a plurality of circumferential collector elements and collector boxes to collect and feed the cooling water into distribution channels extending along the curved surface of the steel containment vessel. The cooling water is uniformly distributed over the curved surface by a plurality of weirs in the distribution channels.
Software for the Design of Swimming Pool Dehumidifiers Units
NASA Astrophysics Data System (ADS)
Rubina, Aleš; Blasinski, Petr; Tesař, Zdeněk
2013-06-01
The article deals with the description and solution of physical phenomena taking place during evaporation of water. The topicality of the theme is given a number of built indoor swimming pool and wellness centers at present. In addressing HVAC systems serving these areas, it is necessary to know the various design parameters in the interior including the water temperature as the pool temperature and humidity. Following is a description of the calculation module, air handling units, including optimizing the settings of the physical changes in order to ensure the lowest energy consumption for air treatment and required maintaining internal microclimate parameters.
Heavy metal pollution in soils of abandoned mining areas (SE, Spain)
NASA Astrophysics Data System (ADS)
Martínez-Sánchez, M. J.; Pérez-Sirvent, C.; Molina, J.; Tudela, M. L.; Navarro, M. C.; García-Lorenzo, M. L.
2009-04-01
Elevated levels of heavy metals can be found in and around disused metalliferous mines due to discharge and dispersion of mine wastes into nearby agricultural soils, food crops and stream systems. Heavy metals contained in the residues from mining and metallurgical operations are often dispersed by wind and/or water after their disposal. These areas have severe erosion problems caused by wind and water runoff in which soil and mine spoil texture, landscape topography and regional and microclimate play an important role. The present study was carried out in the Cabezo Rajao (La Uni
Cooling of superconducting devices by liquid storage and refrigeration unit
Laskaris, Evangelos Trifon; Urbahn, John Arthur; Steinbach, Albert Eugene
2013-08-20
A system is disclosed for cooling superconducting devices. The system includes a cryogen cooling system configured to be coupled to the superconducting device and to supply cryogen to the device. The system also includes a cryogen storage system configured to supply cryogen to the device. The system further includes flow control valving configured to selectively isolate the cryogen cooling system from the device, thereby directing a flow of cryogen to the device from the cryogen storage system.
Smith, Gregory C.; Tokarz, Richard D.; Parry, Jr., Harvey L.; Braun, Daniel J.
1980-01-01
A cooling system for rejecting waste heat consists of a cooling tower incorporating a plurality of coolant tubes provided with cooling fins and each having a plurality of cooling channels therein, means for directing a heat exchange fluid from the power plant through less than the total number of cooling channels to cool the heat exchange fluid under normal ambient temperature conditions, means for directing water through the remaining cooling channels whenever the ambient temperature rises above the temperature at which dry cooling of the heat exchange fluid is sufficient and means for cooling the water.
Rebaudo, François; Faye, Emile; Dangles, Olivier
2016-01-01
A large body of literature has recently recognized the role of microclimates in controlling the physiology and ecology of species, yet the relevance of fine-scale climatic data for modeling species performance and distribution remains a matter of debate. Using a 6-year monitoring of three potato moth species, major crop pests in the tropical Andes, we asked whether the spatiotemporal resolution of temperature data affect the predictions of models of moth performance and distribution. For this, we used three different climatic data sets: (i) the WorldClim dataset (global dataset), (ii) air temperature recorded using data loggers (weather station dataset), and (iii) air crop canopy temperature (microclimate dataset). We developed a statistical procedure to calibrate all datasets to monthly and yearly variation in temperatures, while keeping both spatial and temporal variances (air monthly temperature at 1 km² for the WorldClim dataset, air hourly temperature for the weather station, and air minute temperature over 250 m radius disks for the microclimate dataset). Then, we computed pest performances based on these three datasets. Results for temperature ranging from 9 to 11°C revealed discrepancies in the simulation outputs in both survival and development rates depending on the spatiotemporal resolution of the temperature dataset. Temperature and simulated pest performances were then combined into multiple linear regression models to compare predicted vs. field data. We used an additional set of study sites to test the ability of the results of our model to be extrapolated over larger scales. Results showed that the model implemented with microclimatic data best predicted observed pest abundances for our study sites, but was less accurate than the global dataset model when performed at larger scales. Our simulations therefore stress the importance to consider different temperature datasets depending on the issue to be solved in order to accurately predict species abundances. In conclusion, keeping in mind that the mismatch between the size of organisms and the scale at which climate data are collected and modeled remains a key issue, temperature dataset selection should be balanced by the desired output spatiotemporal scale for better predicting pest dynamics and developing efficient pest management strategies.
Impacts of day versus night warming on soil microclimate: results from a semiarid temperate steppe.
Xia, Jianyang; Chen, Shiping; Wan, Shiqiang
2010-06-15
One feature of climate warming is that increases in daily minimum temperature are greater than those in daily maximum temperature. Changes in soil microclimate in response to the asymmetrically diurnal warming scenarios can help to explain responses of ecosystem processes. In the present study, we examined the impacts of day, night, and continuous warming on soil microclimate in a temperate steppe in northern China. Our results showed that day, night, and continuous warming (approximately 13Wm(-2) with constant power mode) significantly increased daily mean soil temperature at 10cm depth by 0.71, 0.78, and 1.71 degrees C, respectively. Night warming caused greater increases in nighttime mean and daily minimum soil temperatures (0.74 and 0.99 degrees C) than day warming did (0.60 and 0.66 degrees C). However, there were no differences in the increases in daytime mean and daily maximum soil temperature between day (0.81 and 1.13 degrees C) and night (0.81 and 1.10 degrees C) warming. The differential effects of day and night warming on soil temperature varied with environmental factors, including photosynthetic active radiation, vapor-pressure deficit, and wind speed. When compared with the effect of continuous warming on soil temperature, the summed effects of day and night warming were lower during daytime, but greater at night, thus leading to equality at daily scale. Mean volumetric soil moisture at the depth of 0-40cm significantly decreased under continuous warming in both 2006 (1.44 V/V%) and 2007 (0.76 V/V%). Day warming significantly reduced volumetric soil moisture only in 2006, whereas night warming had no effect on volumetric soil moisture in both 2006 and 2007. Given the different diurnal warming patterns and variability of environmental factors among ecosystems, these results highlight the importance of incorporating the differential impacts of day and night warming on soil microclimate into the predictions of terrestrial ecosystem responses to climate warming. Copyright 2010 Elsevier B.V. All rights reserved.
Rebaudo, François; Faye, Emile; Dangles, Olivier
2016-01-01
A large body of literature has recently recognized the role of microclimates in controlling the physiology and ecology of species, yet the relevance of fine-scale climatic data for modeling species performance and distribution remains a matter of debate. Using a 6-year monitoring of three potato moth species, major crop pests in the tropical Andes, we asked whether the spatiotemporal resolution of temperature data affect the predictions of models of moth performance and distribution. For this, we used three different climatic data sets: (i) the WorldClim dataset (global dataset), (ii) air temperature recorded using data loggers (weather station dataset), and (iii) air crop canopy temperature (microclimate dataset). We developed a statistical procedure to calibrate all datasets to monthly and yearly variation in temperatures, while keeping both spatial and temporal variances (air monthly temperature at 1 km² for the WorldClim dataset, air hourly temperature for the weather station, and air minute temperature over 250 m radius disks for the microclimate dataset). Then, we computed pest performances based on these three datasets. Results for temperature ranging from 9 to 11°C revealed discrepancies in the simulation outputs in both survival and development rates depending on the spatiotemporal resolution of the temperature dataset. Temperature and simulated pest performances were then combined into multiple linear regression models to compare predicted vs. field data. We used an additional set of study sites to test the ability of the results of our model to be extrapolated over larger scales. Results showed that the model implemented with microclimatic data best predicted observed pest abundances for our study sites, but was less accurate than the global dataset model when performed at larger scales. Our simulations therefore stress the importance to consider different temperature datasets depending on the issue to be solved in order to accurately predict species abundances. In conclusion, keeping in mind that the mismatch between the size of organisms and the scale at which climate data are collected and modeled remains a key issue, temperature dataset selection should be balanced by the desired output spatiotemporal scale for better predicting pest dynamics and developing efficient pest management strategies. PMID:27148077
Morrison, Lucas M; Unger, Kirk A; Watterson, James H
2017-07-01
Analysis of dextromethorphan (DXM) and its metabolite dextrorphan (DXT) in skeletal remains of rats following acute (ACU, 75 mg/kg, IP, n = 10) or three repeated (REP, 25 mg/kg, IP, n = 10, 40-min interval) doses of DXM is described. Following dosing and euthanasia, rats decomposed outdoors to skeleton in two different microclimate environments (n = 5 ACU and n = 5 REP at each site): Site A (shaded forest microenvironment) and Site B (rocky substrate exposed to direct sunlight, 600 m from Site A). Two drug-free rats at each site served as negative controls. Skeletal elements (vertebrae, ribs, pelvic girdles, femora, tibiae, skulls and scapulae) were recovered, pulverized and underwent methanolic microwave assisted extraction (MAE). Extracts were analyzed by GC-MS following clean-up by solid-phase extraction (SPE). Drug levels, expressed as mass-normalized response ratios and the ratios of DXT and DXM levels (RRDXT/RRDXM) were compared between drug exposures, microclimate sites, and across skeletal elements. DXM levels differed significantly (P < 0.05) between corresponding bone elements across exposure groups (5/7-site A; 4/7-site B), but no significant differences in DXT levels were observed between corresponding elements. RRDXT/RRDXM differed significantly (P < 0.05) between corresponding bone elements across exposure groups (6/7-site A; 5/7-site B). No significant differences were observed in levels of DXM, DXT or RRDXT/RRDXM between corresponding elements from either group between sites. When data from all bone elements was pooled, levels of DXM and RRDXT/RRDXM differed significantly between exposure groups at each site, while those of DXT did not. For both exposure groups, comparison of pooled data between sites showed no significant differences in levels of DXM, DXT or RRDXT/RRDXM. Different decomposition microclimates did not impede the discrimination of DXM exposure patterns from the analyses of DXM, DXT and RRDXT/RRDXM in bone samples. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Realizing ecosystem services: wetland hydrologic function along a gradient of ecosystem condition.
McLaughlin, Daniel L; Cohen, Matthew J
2013-10-01
Wetlands provide numerous ecosystem services, from habitat provision to pollutant removal, floodwater storage, and microclimate regulation. Delivery of particular services relies on specific ecological functions, and thus to varying degree on wetland ecological condition, commonly quantified as departure from minimally impacted reference sites. Condition assessments are widely adopted as regulatory indicators of ecosystem function, and for some services (e.g., habitat) links between condition and function are often direct. For others, however, links are more tenuous, and using condition alone to enumerate ecosystem value (e.g., for compensatory mitigation) may underestimate important services. Hydrologic function affects many services cited in support of wetland protection both directly (floodwater retention, microclimate regulation) and indirectly (biogeochemical cycling, pollutant removal). We investigated links between condition and hydrologic function to test the hypothesis, embedded in regulatory assessment of wetland value, that condition predicts function. Condition was assessed using rapid and intensive approaches, including Florida's official wetland assessment tool, in 11 isolated forested wetlands in north Florida (USA) spanning a land use intensity gradient. Hydrologic function was assessed using hydrologic regime (mean, variance, and rates of change of water depth), and measurements of groundwater exchange and evapotranspiration (ET). Despite a wide range in condition, no systematic variation in hydrologic regime was observed; indeed reference sites spanned the full range of variation. In contrast, ET was affected by land use, with higher rates in intensive (agriculture and urban) landscapes in response to higher leaf area. ET determines latent heat exchange, which regulates microclimate, a valuable service in urban heat islands. Higher ET also indicates higher productivity and thus carbon cycling. Groundwater exchange regularly reversed flow direction at all sites in response to rainfall. This buffering effect on regional aquifer levels, an underappreciated service of isolated wetlands, was provided regardless of condition. Intensive landscapes may benefit most from the hydrologic services that wetlands provide because that is where certain services (floodwater storage, microclimate regulation) are realized. While the portfolio of wetland services clearly changes with disturbance, our results support a revised approach to wetland valuation that recognizes the services that accrue from sustained or enhanced functions in these "working wetlands."
Regional climate modulates the canopy mosaic of favourable and risky microclimates for insects.
Pincebourde, Sylvain; Sinoquet, Herve; Combes, Didier; Casas, Jerome
2007-05-01
1. One major gap in our ability to predict the impacts of climate change is a quantitative analysis of temperatures experienced by organisms under natural conditions. We developed a framework to describe and quantify the impacts of local climate on the mosaic of microclimates and physiological states of insects within tree canopies. This approach was applied to a leaf mining moth feeding on apple leaf tissues. 2. Canopy geometry was explicitly considered by mapping the 3D position and orientation of more than 26 000 leaves in an apple tree. Four published models for canopy radiation interception, energy budget of leaves and mines, body temperature and developmental rate of the leaf miner were integrated. Model predictions were compared with actual microclimate temperatures. The biophysical model accurately predicted temperature within mines at different positions within the tree crown. 3. Field temperature measurements indicated that leaf and mine temperature patterns differ according to the regional climatic conditions (cloudy or sunny) and depending on their location within the canopy. Mines in the sun can be warmer than those in the shade by several degrees and the heterogeneity of mine temperature was incremented by 120%, compared with that of leaf temperature. 4. The integrated model was used to explore the impact of both warm and exceptionally hot climatic conditions recorded during a heat wave on the microclimate heterogeneity at canopy scale. During warm conditions, larvae in sunlight-exposed mines experienced nearly optimal growth conditions compared with those within shaded mines. The developmental rate was increased by almost 50% in the sunny microhabitat compared with the shaded location. Larvae, however, experienced optimal temperatures for their development inside shaded mines during extreme climatic conditions, whereas larvae in exposed mines were overheating, leading to major risks of mortality. 5. Tree canopies act as both magnifiers and reducers of the climatic regime experienced in open air outside canopies. Favourable and risky spots within the canopy do change as a function of the climatic conditions at the regional scale. The shifting nature of the mosaic of suitable and risky habitats may explain the observed uniform distribution of leaf miners within tree canopies.
Description and cost analysis of a deluge dry/wet cooling system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wiles, L.E.; Bamberger, J.A.; Braun, D.J.
1978-06-01
The use of combined dry/wet cooling systems for large base-load power plants offers the potential for significant water savings as compared to evaporatively cooled power plants and significant cost savings in comparison to dry cooled power plants. The results of a detailed engineering and cost study of one type of dry/wet cooling system are described. In the ''deluge'' dry/wet cooling method, a finned-tube heat exchanger is designed to operate in the dry mode up to a given ambient temperature. To avoid the degradation of performance for higher ambient temperatures, water (the delugeate) is distributed over a portion of the heatmore » exchanger surface to enhance the cooling process by evaporation. The deluge system used in this study is termed the HOETERV system. The HOETERV deluge system uses a horizontal-tube, vertical-plate-finned heat exchanger. The delugeate is distributed at the top of the heat exchanger and is allowed to fall by gravity in a thin film on the face of the plate fin. Ammonia is used as the indirect heat transfer medium between the turbine exhaust steam and the ambient air. Steam is condensed by boiling ammonia in a condenser/reboiler. The ammonia is condensed in the heat exchanger by inducing airflow over the plate fins. Various design parameters of the cooling system have been studied to evaluate their impact on the optimum cooling system design and the power-plant/utility-system interface. Annual water availability was the most significant design parameter. Others included site meteorology, heat exchanger configuration and air flow, number and size of towers, fan system design, and turbine operation. It was concluded from this study that the HOETERV deluge system of dry/wet cooling, using ammonia as an intermediate heat transfer medium, offers the potential for significant cost savings compared with all-dry cooling, while achieving substantially reduced water consumption as compared to an evaporatively cooled power plant. (LCL)« less
Numerical modelling of series-parallel cooling systems in power plant
NASA Astrophysics Data System (ADS)
Regucki, Paweł; Lewkowicz, Marek; Kucięba, Małgorzata
2017-11-01
The paper presents a mathematical model allowing one to study series-parallel hydraulic systems like, e.g., the cooling system of a power boiler's auxiliary devices or a closed cooling system including condensers and cooling towers. The analytical approach is based on a set of non-linear algebraic equations solved using numerical techniques. As a result of the iterative process, a set of volumetric flow rates of water through all the branches of the investigated hydraulic system is obtained. The calculations indicate the influence of changes in the pipeline's geometrical parameters on the total cooling water flow rate in the analysed installation. Such an approach makes it possible to analyse different variants of the modernization of the studied systems, as well as allowing for the indication of its critical elements. Basing on these results, an investor can choose the optimal variant of the reconstruction of the installation from the economic point of view. As examples of such a calculation, two hydraulic installations are described. One is a boiler auxiliary cooling installation including two screw ash coolers. The other is a closed cooling system consisting of cooling towers and condensers.
Floating Loop System For Cooling Integrated Motors And Inverters Using Hot Liquid Refrigerant
Hsu, John S [Oak Ridge, TN; Ayers, Curtis W [Kingston, TN; Coomer, Chester [Knoxville, TN; Marlino, Laura D [Oak Ridge, TN
2006-02-07
A floating loop vehicle component cooling and air-conditioning system having at least one compressor for compressing cool vapor refrigerant into hot vapor refrigerant; at least one condenser for condensing the hot vapor refrigerant into hot liquid refrigerant by exchanging heat with outdoor air; at least one floating loop component cooling device for evaporating the hot liquid refrigerant into hot vapor refrigerant; at least one expansion device for expanding the hot liquid refrigerant into cool liquid refrigerant; at least one air conditioning evaporator for evaporating the cool liquid refrigerant into cool vapor refrigerant by exchanging heat with indoor air; and piping for interconnecting components of the cooling and air conditioning system.
A portable personal cooling system for mine rescue operations
NASA Technical Reports Server (NTRS)
Webbon, B.; Williams, B.; Kirk, P.; Elkins, W.; Stein, R.
1977-01-01
Design of a portable personal cooling system to reduce physiological stress in high-temperature, high-humidity conditions is discussed. The system, based on technology used in the thermal controls of space suits, employs a combination of head and thoracic insulation and cooling through a heat sink unit. Average metabolic rates, heart rates, rectal temperature increase and sweat loss were monitored for test subjects wearing various configurations of the cooling system, as well as for a control group. The various arrangements of the cooling garment were found to provide significant physiological benefits; however, increases in heat transfer rate of the cooling unit and more effective insulation are suggested to improve the system's function.
[Water-saving mechanisms of intercropping system in improving cropland water use efficiency].
Zhang, Feng-Yun; Wu, Pu-Te; Zhao, Xi-Ning; Cheng, Xue-Feng
2012-05-01
Based on the multi-disciplinary researches, and in terms of the transformation efficiency of surface water to soil water, availability of cropland soil water, crop canopy structure, total irrigation volume needed on a given area, and crop yield, this paper discussed the water-saving mechanisms of intercropping system in improving cropland water use efficiency. Intercropping system could promote the full use of cropland water by plant roots, increase the water storage in root zone, reduce the inter-row evaporation and control excessive transpiration, and create a special microclimate advantageous to the plant growth and development. In addition, intercropping system could optimize source-sink relationship, provide a sound foundation for intensively utilizing resources temporally and spatially, and increase the crop yield per unit area greatly without increase of water consumption, so as to promote the crop water use efficiency effectively.
Chainer, Timothy J; Dang, Hien P; Parida, Pritish R; Schultz, Mark D; Sharma, Arun
2015-03-17
A data center cooling system may include heat transfer equipment to cool a liquid coolant without vapor compression refrigeration, and the liquid coolant is used on a liquid cooled information technology equipment rack housed in the data center. The system may also include a controller-apparatus to regulate the liquid coolant flow to the liquid cooled information technology equipment rack through a range of liquid coolant flow values based upon information technology equipment temperature thresholds.
Experimental study of hybrid interface cooling system using air ventilation and nanofluid
NASA Astrophysics Data System (ADS)
Rani, M. F. H.; Razlan, Z. M.; Bakar, S. A.; Desa, H.; Wan, W. K.; Ibrahim, I.; Kamarrudin, N. S.; Bin-Abdun, Nazih A.
2017-09-01
The hybrid interface cooling system needs to be established to chill the battery compartment of electric car and maintained its ambient temperature inside the compartment between 25°C to 35°C. The air cooling experiment has been conducted to verify the cooling capacity, compressor displacement volume, dehumidifying value and mass flow rate of refrigerant (R-410A). At the same time, liquid cooling system is analysed theoretically by comparing the performance of two types of nanofluid, i.e., CuO + Water and Al2O3 + Water, based on the heat load generated inside the compartment. In order for the result obtained to be valid and reliable, several assumptions are considered during the experimental and theoretical analysis. Results show that the efficiency of the hybrid interface cooling system is improved as compared to the individual cooling system.
System and method of active vibration control for an electro-mechanically cooled device
Lavietes, Anthony D.; Mauger, Joseph; Anderson, Eric H.
2000-01-01
A system and method of active vibration control of an electro-mechanically cooled device is disclosed. A cryogenic cooling system is located within an environment. The cooling system is characterized by a vibration transfer function, which requires vibration transfer function coefficients. A vibration controller generates the vibration transfer function coefficients in response to various triggering events. The environments may differ by mounting apparatus, by proximity to vibration generating devices, or by temperature. The triggering event may be powering on the cooling system, reaching an operating temperature, or a reset action. A counterbalance responds to a drive signal generated by the vibration controller, based on the vibration signal and the vibration transfer function, which adjusts vibrations. The method first places a cryogenic cooling system within a first environment and then generates a first set of vibration transfer function coefficients, for a vibration transfer function of the cooling system. Next, the cryogenic cooling system is placed within a second environment and a second set of vibration transfer function coefficients are generated. Then, a counterbalance is driven, based on the vibration transfer function, to reduce vibrations received by a vibration sensitive element.
He, Yingdong; Li, Nianping; Wang, Xiang; He, Meiling; He, De
2017-11-17
It is well known that personal cooling improves thermal comfort and save energy. This study aims to: (1) compare different personal cooling systems and (2) understand what influences users' willingness to adopt them. A series of experiments on several types of personal cooling systems, which included physical measurements, questionnaires and feedback, was conducted in a real office environment. The obtained results showed that personal cooling improved comfort of participants in warm environments. Then an improved index was proposed and used to compare different types of personal cooling systems in terms of comfort and energy efficiency simultaneously. According to the improved index, desk fans were highly energy-efficient, while the hybrid personal cooling (the combination of radiant cooling desk and desk fan) consumed more energy but showed advantages of extending the comfortable temperature range. Moreover, if personal cooling was free, most participants were willing to adopt it and the effectiveness was the main factor influencing their willingness, whereas if participants had to pay, they probably refused to adopt it due to the cost and the availability of conventional air conditioners. Thus, providing effective and free personal cooling systems should be regarded as a better way for its wider application.
Design and evaluation of active cooling systems for Mach 6 cruise vehicle wings
NASA Technical Reports Server (NTRS)
Mcconarty, W. A.; Anthony, F. M.
1971-01-01
Active cooling systems, which included transpiration, film, and convective cooling concepts, are examined. Coolants included hydrogen, helium, air, and water. Heat shields, radiation barriers, and thermal insulation are considered to reduce heat flow to the cooling systems. Wing sweep angles are varied from 0 deg to 75 deg and wing leading edge radii of 0.05 inch and 2.0 inches are examined. Structural temperatures are varied to allow comparison of aluminum alloy, titanium alloy, and superalloy structural materials. Cooled wing concepts are compared among themselves, and with the uncooled concept on the basis of structural weight, cooling system weight, and coolant weight.
Sub-cooled liquid nitrogen cryogenic system with neon turbo-refrigerator for HTS power equipment
NASA Astrophysics Data System (ADS)
Yoshida, S.; Hirai, H.; Nara, N.; Ozaki, S.; Hirokawa, M.; Eguchi, T.; Hayashi, H.; Iwakuma, M.; Shiohara, Y.
2014-01-01
We developed a prototype sub-cooled liquid nitrogen (LN) circulation system for HTS power equipment. The system consists of a neon turbo-Brayton refrigerator with a LN sub-cooler and LN circulation pump unit. The neon refrigerator has more than 2 kW cooling power at 65 K. The LN sub-cooler is a plate-fin type heat exchanger and is installed in a refrigerator cold box. In order to carry out the system performance tests, a dummy cryostat having an electric heater was set instead of a HTS power equipment. Sub-cooled LN is delivered into the sub-cooler by the LN circulation pump and cooled within it. After the sub-cooler, sub-cooled LN goes out from the cold box to the dummy cryostat, and comes back to the pump unit. The system can control an outlet sub-cooled LN temperature by adjusting refrigerator cooling power. The refrigerator cooling power is automatically controlled by the turbo-compressor rotational speed. In the performance tests, we increased an electric heater power from 200 W to 1300 W abruptly. We confirmed the temperature fluctuation was about ±1 K. We show the cryogenic system details and performance test results in this paper.
Evaporative cooling for Holstein dairy cows under grazing conditions
NASA Astrophysics Data System (ADS)
Valtorta, Silvia E.; Gallardo, Miriam R.
. Twenty-four grazing Holstein cows in mid and late lactation were randomly assigned to two treatment groups: control and cooled. The trial was performed at the Experimental Dairy Unit, Rafaela Agricultural Experimental Station (INTA), Argentina. The objective was to evaluate the effects of sprinkler and fan cooling before milkings on milk production and composition. The effects of the cooling system on rectal temperature and respiration rate were also evaluated. Cooled cows showed higher milk production (1.04 l cow-1 day-1). The concentration and yield of milk fat and protein increased in response to cooling treatment. The cooling system also reduced rectal temperature and respiration rate. No effects were observed on body condition. It was concluded that evaporative cooling, which is efficient for housed animals, is also appropriate to improve yields and animal well-being under grazing systems. These results are impressive since the cooling system was utilized only before milkings, in a system where environmental control is very difficult to achieve. This trial was performed during a mild summer. The results would probably be magnified during hotter weather.
Apple production and quality when cultivated under anti-hail cover in Southern Brazil
NASA Astrophysics Data System (ADS)
Bosco, Leosane Cristina; Bergamaschi, Homero; Cardoso, Loana Silveira; de Paula, Viviane Aires; Marodin, Gilmar Arduino Bettio; Nachtigall, Gilmar Ribeiro
2015-07-01
Anti-hail nets may change the microclimate of orchards and hence modify the physicochemical and sensory characteristics of fruits. The present study aimed to evaluate the effects of anti-hail nets on the physical, chemical, and sensory attributes of apples grown in southern Brazil. The study was conducted in commercial orchards, with apples grown under a black anti-hail net under an open sky during the 2008/2009, 2009/2010, and 2010/2011 cycles. Measurements of photosynthetically active radiation were collected at both sites. Physical, chemical, and sensory analyses of fruits were performed in the laboratory. The anti-hail net reduced incident photosynthetically active radiation by 32 %. The light spectrum in the canopy changed the corresponding R/FR (red/far-red) ratio in the lower and upper canopy layers from 0.27 to 1.55, respectively. In contrast to the majority of microclimate studies carried out in the temperate zones of the northern hemisphere, this study in the southern hemisphere showed that although it reduced the incident solar radiation, the cover did not change the color or organoleptic characteristics of "Royal Gala" and "Fuji Suprema" apples. The net cover prolonged the subperiod between fruit setting and harvesting, thus slowing fruit ripening. Therefore, the use of anti-hail nets on apple orchards is a suitable alternative for the protection of apple trees against hail because it causes only small changes in the microclimate and in the maturation period, ensuring fruit production without affecting its quality.
Apple production and quality when cultivated under anti-hail cover in Southern Brazil.
Bosco, Leosane Cristina; Bergamaschi, Homero; Cardoso, Loana Silveira; de Paula, Viviane Aires; Marodin, Gilmar Arduino Bettio; Nachtigall, Gilmar Ribeiro
2015-07-01
Anti-hail nets may change the microclimate of orchards and hence modify the physicochemical and sensory characteristics of fruits. The present study aimed to evaluate the effects of anti-hail nets on the physical, chemical, and sensory attributes of apples grown in southern Brazil. The study was conducted in commercial orchards, with apples grown under a black anti-hail net under an open sky during the 2008/2009, 2009/2010, and 2010/2011 cycles. Measurements of photosynthetically active radiation were collected at both sites. Physical, chemical, and sensory analyses of fruits were performed in the laboratory. The anti-hail net reduced incident photosynthetically active radiation by 32%. The light spectrum in the canopy changed the corresponding R/FR (red/far-red) ratio in the lower and upper canopy layers from 0.27 to 1.55, respectively. In contrast to the majority of microclimate studies carried out in the temperate zones of the northern hemisphere, this study in the southern hemisphere showed that although it reduced the incident solar radiation, the cover did not change the color or organoleptic characteristics of "Royal Gala" and "Fuji Suprema" apples. The net cover prolonged the subperiod between fruit setting and harvesting, thus slowing fruit ripening. Therefore, the use of anti-hail nets on apple orchards is a suitable alternative for the protection of apple trees against hail because it causes only small changes in the microclimate and in the maturation period, ensuring fruit production without affecting its quality.
Baiocchi, Valerio; Zottele, Fabio; Dominici, Donatella
2017-01-01
This work reports a first attempt to use Landsat satellite imagery to identify possible urban microclimate changes in a city center after a seismic event that affected L’Aquila City (Abruzzo Region, Italy), on 6 April 2009. After the main seismic event, the collapse of part of the buildings, and the damaging of most of them, with the consequence of an almost total depopulation of the historic city center, may have caused alterations to the microclimate. This work develops an inexpensive work flow—using Landsat Enhanced Thematic Mapper Plus (ETM+) scenes—to construct the evolution of urban land use after the catastrophic main seismic event that hit L’Aquila. We hypothesized, that, possibly, before the event, the temperature was higher in the city center due to the presence of inhabitants (and thus home heating); while the opposite case occurred in the surrounding areas, where new settlements of inhabitants grew over a period of a few months. We decided not to look to independent meteorological data in order to avoid being biased in their investigations; thus, only the smallest dataset of Landsat ETM+ scenes were considered as input data in order to describe the thermal evolution of the land surface after the earthquake. We managed to use the Landsat archive images to provide thermal change indications, useful for understanding the urban changes induced by catastrophic events, setting up an easy to implement, robust, reproducible, and fast procedure. PMID:28218724
Baiocchi, Valerio; Zottele, Fabio; Dominici, Donatella
2017-02-19
This work reports a first attempt to use Landsat satellite imagery to identify possible urban microclimate changes in a city center after a seismic event that affected L'Aquila City (Abruzzo Region, Italy), on 6 April 2009. After the main seismic event, the collapse of part of the buildings, and the damaging of most of them, with the consequence of an almost total depopulation of the historic city center, may have caused alterations to the microclimate. This work develops an inexpensive work flow-using Landsat Enhanced Thematic Mapper Plus (ETM+) scenes-to construct the evolution of urban land use after the catastrophic main seismic event that hit L'Aquila. We hypothesized, that, possibly, before the event, the temperature was higher in the city center due to the presence of inhabitants (and thus home heating); while the opposite case occurred in the surrounding areas, where new settlements of inhabitants grew over a period of a few months. We decided not to look to independent meteorological data in order to avoid being biased in their investigations; thus, only the smallest dataset of Landsat ETM+ scenes were considered as input data in order to describe the thermal evolution of the land surface after the earthquake. We managed to use the Landsat archive images to provide thermal change indications, useful for understanding the urban changes induced by catastrophic events, setting up an easy to implement, robust, reproducible, and fast procedure.
Ginocchio, Rosanna; Carvallo, Gastón; Toro, Ignacia; Bustamante, Elena; Silva, Yasna; Sepúlveda, Nancy
2004-01-01
Soil chemical changes produced by metal smelters have mainly been studied on a large scale. In terms of plant survival, determination of small scale variability may be more important because less toxic microhabitats may represent safe sites for successful recruitment and thus for plant survival. Three dominant microhabitats (open spaces and areas below the canopy of Sphaeralcea obtusiloba and Baccharis linearis shrubs) were defined in a heavily polluted area near a copper smelter and characterised in terms of microclimate, general soil chemistry, total and extractable metal concentrations in the soil profile (A0 horizon, 0-5 and 15-20 cm depth), and seedling densities. Results indicated a strong variability in microclimate and soil chemistry not only in the soil profile but also among microhabitats. Air/soil temperatures, radiation and wind speed were much lower under the canopy of shrubs, particularly during the plant growth season. Soil acidification was detected on top layers (0-5 cm depth) of all microhabitats while higher concentrations of N, Cu and Cd were detected on litter and top soil layers below shrubs when compared to open spaces; however, high organic matter content below shrubs decreased bioavailability of metals. Plant recruitment was concentrated under shrub canopies; this may be explained as a result of the nursery effect exerted by shrubs in terms of providing a more favourable microclimate, along with better soil conditions in terms of macronutrients and metal bioavailability.
Suuronen, Anna; Muñoz-Escobar, Christian; Lensu, Anssi; Kuitunen, Markku; Guajardo Celis, Natalia; Espinoza Astudillo, Pablo; Ferrú, Marcos; Taucare-Ríos, Andrés; Miranda, Marcelo; Kukkonen, Jussi V K
2017-10-01
The renewable energy sector is growing at a rapid pace in northern Chile and the solar energy potential is one of the best worldwide. Therefore, many types of solar power plant facilities are being built to take advantage of this renewable energy resource. Solar energy is considered a clean source of energy, but there are potential environmental effects of solar technology, such as landscape fragmentation, extinction of local biota, microclimate changes, among others. To be able to minimize environmental impacts of solar power plants, it is important to know what kind of environmental conditions solar power plants create. This study provides information about abiotic and biotic conditions in the vicinity of photovoltaic solar power plants. Herein, the influence of these power plants as drivers of new microclimate conditions and arthropods diversity composition in the Atacama Desert was evaluated. Microclimatic conditions between panel mounts was found to be more extreme than in the surrounding desert yet beneath the panels temperature is lower and relative humidity higher than outside the panel area. Arthropod species composition was altered in fixed-mount panel installations. In contrast, solar tracking technology showed less influence on microclimate and species composition between Sun and Shade in the power plant. Shady conditions provided a refuge for arthropod species in both installation types. For example, Dipterans were more abundant in the shade whereas Solifugaes were seldom present in the shade. The presented findings have relevance for the sustainable planning and construction of solar power plants.
NASA Astrophysics Data System (ADS)
Suuronen, Anna; Muñoz-Escobar, Christian; Lensu, Anssi; Kuitunen, Markku; Guajardo Celis, Natalia; Espinoza Astudillo, Pablo; Ferrú, Marcos; Taucare-Ríos, Andrés; Miranda, Marcelo; Kukkonen, Jussi V. K.
2017-10-01
The renewable energy sector is growing at a rapid pace in northern Chile and the solar energy potential is one of the best worldwide. Therefore, many types of solar power plant facilities are being built to take advantage of this renewable energy resource. Solar energy is considered a clean source of energy, but there are potential environmental effects of solar technology, such as landscape fragmentation, extinction of local biota, microclimate changes, among others. To be able to minimize environmental impacts of solar power plants, it is important to know what kind of environmental conditions solar power plants create. This study provides information about abiotic and biotic conditions in the vicinity of photovoltaic solar power plants. Herein, the influence of these power plants as drivers of new microclimate conditions and arthropods diversity composition in the Atacama Desert was evaluated. Microclimatic conditions between panel mounts was found to be more extreme than in the surrounding desert yet beneath the panels temperature is lower and relative humidity higher than outside the panel area. Arthropod species composition was altered in fixed-mount panel installations. In contrast, solar tracking technology showed less influence on microclimate and species composition between Sun and Shade in the power plant. Shady conditions provided a refuge for arthropod species in both installation types. For example, Dipterans were more abundant in the shade whereas Solifugaes were seldom present in the shade. The presented findings have relevance for the sustainable planning and construction of solar power plants.
Deforestation, fire susceptibility, and potential tree responses to fire in the eastern Amazon
DOE Office of Scientific and Technical Information (OSTI.GOV)
Uhl, C.; Kauffman, J.B.
1990-04-01
In the state of Para, Brazil, in the eastern Amazon, the authors studied the potential for sustained fire events within four dominant vegetation cover types (undisturbed rain forest, selectively logged forest, second-growth forest, and open pasture), by measuring fuel availability, microclimate, and rates of fuel moisture loss. They also estimated the potential tree mortality that might result from a wide-scale Amazon forest fire by measuring the thermal properties of bark for all trees in a 5-ha stand of mature forest, followed by measurements of heat flux through bark during simulated fires. In pastures the average midday temperature was almost 10{degree}Cmore » greater and the average midday relative humidity was 30% lower than in primary forest. The most five-prone ecosystem was the open pasture followed by selectively logged forest, second growth forest, and undisturbed rain forest in which sustained combustion was not possible even after prolonged rainless periods. Even though the autogenic factors in primary forest of the eastern Amazon create a microclimate that virtually eliminates the probability of fire, they are currently a common event in disturbed areas of Amazonia. As many as 8 {times} 10{sup 6} ha burned in the Amazon Basin of Brazil in 1987 alone. In terms of current land-use patterns, altered microclimates, and fuel mass, there are also striking similarities between the eastern Amazon and East Kalimantan, Indonesia (the site of recent rain forest wildfires that burned 3.5 {times} 10{sup 6} ha).« less
The vulva skin microclimate: influence of panty liners on temperature, humidity and pH.
Runeman, Bo; Rybo, Göran; Larkö, Olle; Faergemann, Jan
2003-01-01
Many women use panty liners between menstrual periods. The aim of this study was to investigate whether the use of such products might influence the vulva skin. Twelve healthy women were studied on four occasions with three different product constructions and on one occasion without products. Temperature, surface wetness and surface pH were measured on vulva skin. Mean skin temperature when the women were wearing a conventional panty liner (with a non-breathable back sheet) was 35.9 degrees C, compared to 34.4 degrees C when wearing no panty liner at all (p < 0.01) and 34.5 degrees C when using a panty liner with a breathable (i.e. vapour permeable) back sheet (p < 0.01). Skin humidity was significantly higher when the conventional panty liner was used compared to no panty liner or to the breathable panty liner (both cases p < 0.01). The mean pH value at the exterior aspect of the labium majus was 5.8 with the conventional panty liner, 5.2 with no panty liner and 5.3 with the breathable panty liner (p < 0.001 and p < 0.01, respectively). The results indicate that the conventional panty liner changes the vulva skin microclimate, but that the breathable panty liner to a substantial degree keeps the microclimate at an undisturbed level. The actual effect of these differences on microbiological flora will be addressed in a subsequent study.
Hemodynamic Responses to Head and Neck Cooling
NASA Technical Reports Server (NTRS)
Ku, Yu-Tsuan E.; Carbo, Jorge E.; Montgomery, Leslie D.; Webbon, Bruce W.
1994-01-01
Personal thermoregulatory systems which provide head and neck cooling are used in the industrial and aerospace environments to alleviate thermal stress. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objective of this study was to measure the scalp temperature and circulatory responses during use of one commercially available thermal control system. The Life Support Systems, Inc. Mark VII portable cooling system and a liquid cooling helmet were used in this study. Two EEG electrodes and one skin temperature transducer were placed on the anterior midline of the scalp to measure the scalp blood and temperature. Blood flow was measured using a bipolar impedance rheograph. Ten subjects, seated in an upright position at normal room temperature, were tested at high, medium, moderate, moderate-low and low coolant temperatures. Scalp blood flow was recorded continuously using a computer data acquisition system with a sampling frequency of 200 Hz. Scalp temperature and cooling helmet Inlet temperature was logged periodically during the test period. This study quantifies the effect of head cooling upon scalp temperature and blood flow. These data may also be used to select operational specifications of the head cooling system for biomedical applications such as the treatment of migraine headaches, scalp cooling during chemotherapy, and cooling of multiple sclerosis patients.
Hemodynamic and Thermal Responses to Head and Neck Cooling in Men and Women
NASA Technical Reports Server (NTRS)
Ku, Yu-Tsuan E.; Montgomery, Leslie D.; Carbo, Jorge E.; Webbon, Bruce W.
1995-01-01
Personal cooling systems are used to alleviate symptoms of multiple sclerosis and to prevent increased core temperature during daily activities. Configurations of these systems include passive ice vests and circulating liquid cooling garments (LCGs) in the forms of vests, cooling caps and combined head and neck cooling systems. However, little information is available oil the amount or heat that can be extracted from the body with these systems or the physiologic changes produced by routine operation of these systems. The objective of this study was to determine the operating characteristics and the physiologic change, produced by short term use of one commercially available thermal control system.
NASA Astrophysics Data System (ADS)
Wang, Dongqing; Liu, Yu; Jiang, Jin; Pang, Wei; Lau, Woon Ming; Mei, Jun
2017-05-01
In the design of nuclear power plants, various natural circulation passive cooling systems are considered to remove residual heat from the reactor core in the event of a power loss and maintain the plant's safety. These passive systems rely on gravity differences of fluids, resulting from density differentials, rather than using an external power-driven system. Unfortunately, a major drawback of such systems is their weak driving force, which can negatively impact safety. In such systems, there is a temperature difference between the heat source and the heat sink, which potentially offers a natural platform for thermoelectric generator (TEG) applications. While a previous study designed and analyzed a TEG-based passive core cooling system, this paper considers TEG applications in other passive cooling systems of nuclear power plants, after which the concept of a TEG-based passive cooling system is proposed. In such a system, electricity is produced using the system's temperature differences through the TEG, and this electricity is used to further enhance the cooling process.
Solar heating and cooling system design and development
NASA Technical Reports Server (NTRS)
1978-01-01
The development of eight prototype solar heating and combined heating and cooling systems is reported. Manufacture, test, installation, maintenance, problem resolution, and monitoring the operation of prototype systems is included. Heating and cooling equipment for single family residential and commercial applications and eight operational test sites (four heating and four heating and cooling) is described.
78 FR 63516 - Initial Test Program of Emergency Core Cooling Systems for New Boiling-Water Reactors
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-24
... NUCLEAR REGULATORY COMMISSION [NRC-2012-0134] Initial Test Program of Emergency Core Cooling....79.1, ``Initial Test Program of Emergency Core Cooling Systems for New Boiling-Water Reactors.'' This... emergency core cooling systems (ECCSs) for boiling- water reactors (BWRs) whose licenses are issued after...
Cooling System Design for PEM Fuel Cell Powered Air Vehicles
2010-06-18
Research Laboratory (NRL) has developed a proton exchange membrane fuel cell ( PEMFC ) powered unmanned air vehicle (UAV) called the Ion Tiger. The Ion Tiger...to design a cooling system for the Ion Tiger and investigate cooling approaches that may be suitable for future PEMFC powered air vehicles. The...modifications) to other PEMFC systems utilizing a CHE for cooling. 18-06-2010 Memorandum Report Unmanned Air Vehicle UAV Fuel cell PEM Cooling Radiator January
Modeling Urban Energy Savings Scenarios Using Earth System Microclimate and Urban Morphology
NASA Astrophysics Data System (ADS)
Allen, M. R.; Rose, A.; New, J. R.; Yuan, J.; Omitaomu, O.; Sylvester, L.; Branstetter, M. L.; Carvalhaes, T. M.; Seals, M.; Berres, A.
2017-12-01
We analyze and quantify the relationships among climatic conditions, urban morphology, population, land cover, and energy use so that these relationships can be used to inform energy-efficient urban development and planning. We integrate different approaches across three research areas: earth system modeling; impacts, adaptation and vulnerability; and urban planning in order to address three major gaps in the existing capability in these areas: i) neighborhood resolution modeling and simulation of urban micrometeorological processes and their effect on and from regional climate; ii) projections for future energy use under urbanization and climate change scenarios identifying best strategies for urban morphological development and energy savings; iii) analysis and visualization tools to help planners optimally use these projections.
NASA Astrophysics Data System (ADS)
Golikov, S. Yu; Petukhov, V. I.; Maiorov, I. S.
2017-11-01
The features of artificial landscapes’ spatial systems created for the optimization of industry facilities and settlements (as well as forest and agricultural crops taking into account the optimality of the existing microclimate and the possibilities for its improvement) are discussed in the paper. They improve the population health (through the optimization of the environment of settlements), the health of farm animals, the state of crops (through optimization of the climate), watercourses and forests reducing catastrophes on the shores and slopes by the proper selection and placement of species for artificial planting. They are achieved by revegetation, greening, garden and landscape design. In general, their purpose is to optimize the human environment.
BPM System for Electron Cooling in the Fermilab Recycler Ring
DOE Office of Scientific and Technical Information (OSTI.GOV)
Joireman, Paul W.; Cai, Jerry; Chase, Brian E.
2004-11-10
We report a VXI based system used to acquire and process BPM data for the electron cooling system in the Fermilab Recycler ring. The BPM system supports acquisition of data from 19 BPM locations in five different sections of the electron cooling apparatus. Beam positions for both electrons and anti-protons can be detected simultaneously with a resolution of {+-}50 {mu}m. We calibrate the system independently for each beam type at each BPM location. We describe the system components, signal processing and modes of operation used in support of the electron-cooling project and present experimental results of system performance for themore » developmental electron cooling installation at Fermilab.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Murav’ev, V. P., E-mail: murval1@mail.ru; Kochetkov, A. V.; Glazova, E. G.
A mathematical model and algorithms are proposed for automatic calculation of the optimum flow rate of cooling water in nuclear and thermal power plants with cooling systems of arbitrary complexity. An unlimited number of configuration and design variants are assumed with the possibility of obtaining a result for any computational time interval, from monthly to hourly. The structural solutions corresponding to an optimum cooling water flow rate can be used for subsequent engineering-economic evaluation of the best cooling system variant. The computerized mathematical model and algorithms make it possible to determine the availability and degree of structural changes for themore » cooling system in all stages of the life cycle of a plant.« less
Ultra-low-vibration pulse-tube cryocooler system - cooling capacity and vibration
NASA Astrophysics Data System (ADS)
Ikushima, Yuki; Li, Rui; Tomaru, Takayuki; Sato, Nobuaki; Suzuki, Toshikazu; Haruyama, Tomiyoshi; Shintomi, Takakazu; Yamamoto, Akira
2008-09-01
This report describes the development of low-vibration cooling systems with pulse-tube (PT) cryocoolers. Generally, PT cryocoolers have the advantage of lower vibrations in comparison to those of GM cryocoolers. However, cooling systems for the cryogenic laser interferometer observatory (CLIO), which is a gravitational wave detector, require an operational vibration that is sufficiently lower than that of a commercial PT cryocooler. The required specification for the vibration amplitude in cold stages is less than ±1 μm. Therefore, during the development of low-vibration cooling systems for the CLIO, we introduced advanced countermeasures for commercial PT cryocoolers. The cooling performance and the vibration amplitude were evaluated. The results revealed that 4 K and 80 K PT cooling systems with a vibration amplitude of less than ±1 μm and cooling performance of 4.5 K and 70 K at heat loads of 0.5 W and 50 W, respectively, were developed successfully.
NASA Technical Reports Server (NTRS)
Makinen, Janice V.; Anchondo, Ian; Bue, Grant C.; Campbell, Colin; Colunga, Aaron
2012-01-01
The development of the Advanced Extravehicular Mobility Unit (AEMU) Portable Life Support System (PLSS) is currently underway at NASA Johnson Space Center. The AEMU PLSS features two new evaporative cooling systems, the Reduced Volume Prototype Spacesuit Water Membrane Evaporator (RVP SWME), and the Auxiliary Cooling Loop (ACL). The RVP SWME is the third generation of hollow fiber SWME hardware, and like its predecessors, RVP SWME provides nominal crewmember and electronics cooling by flowing water through porous hollow fibers. Water vapor escapes through the hollow fiber pores, thereby cooling the liquid water that remains inside of the fibers. This cooled water is then recirculated to remove heat from the crewmember and PLSS electronics. Major design improvements, including a 36% reduction in volume, reduced weight, and more flight like back-pressure valve, facilitate the packaging of RVP SWME in the AEMU PLSS envelope. In addition to the RVP SWME, the Auxiliary Cooling Loop (ACL), was developed for contingency crewmember cooling. The ACL is a completely redundant, independent cooling system that consists of a small evaporative cooler--the Mini Membrane Evaporator (Mini-ME), independent pump, independent feed-water assembly and independent Liquid Cooling Garment (LCG). The Mini-ME utilizes the same hollow fiber technology featured in the RVP SWME, but is only 25% of the size of RVP SWME, providing only the necessary crewmember cooling in a contingency situation. The ACL provides a number of benefits when compared with the current EMU PLSS contingency cooling technology; contingency crewmember cooling can be provided for a longer period of time, more contingency situations can be accounted for, no reliance on a Secondary Oxygen Vessel (SOV) for contingency cooling--thereby allowing a SOV reduction in size and pressure, and the ACL can be recharged-allowing the AEMU PLSS to be reused, even after a contingency event. The development of these evaporative cooling systems will contribute to a more robust and comprehensive AEMU PLSS.
Passive wall cooling panel with phase change material as a cooling agent
NASA Astrophysics Data System (ADS)
Majid, Masni A.; Tajudin, Rasyidah Ahmad; Salleh, Norhafizah; Hamid, Noor Azlina Abd
2017-11-01
The study was carried out to the determine performance of passive wall cooling panels by using Phase Change Materials as a cooling agent. This passive cooling system used cooling agent as natural energy storage without using any HVAC system. Eight full scale passive wall cooling panels were developed with the size 1500 mm (L) × 500 mm (W) × 100 mm (T). The cooling agent such as glycerine were filled in the tube with horizontal and vertical arrangement. The passive wall cooling panels were casting by using foamed concrete with density between 1200 kg/m3 - 1500 kg/m3. The passive wall cooling panels were tested in a small house and the differences of indoor and outdoor temperature was recorded. Passive wall cooling panels with glycerine as cooling agent in vertical arrangement showed the best performance with dropped of indoor air temperature within 3°C compared to outdoor air temperature. The lowest indoor air temperature recorded was 25°C from passive wall cooling panels with glycerine in vertical arrangement. From this study, the passive wall cooling system could be applied as it was environmental friendly and less maintenance.
Water cooling system for an air-breathing hypersonic test vehicle
NASA Technical Reports Server (NTRS)
Petley, Dennis H.; Dziedzic, William M.
1993-01-01
This study provides concepts for hypersonic experimental scramjet test vehicles which have low cost and low risk. Cryogenic hydrogen is used as the fuel and coolant. Secondary water cooling systems were designed. Three concepts are shown: an all hydrogen cooling system, a secondary open loop water cooled system, and a secondary closed loop water cooled system. The open loop concept uses high pressure helium (15,000 psi) to drive water through the cooling system while maintaining the pressure in the water tank. The water flows through the turbine side of the turbopump to pump hydrogen fuel. The water is then allowed to vent. In the closed loop concept high pressure, room temperature, compressed liquid water is circulated. In flight water pressure is limited to 6000 psi by venting some of the water. Water is circulated through cooling channels via an ejector which uses high pressure gas to drive a water jet. The cooling systems are presented along with finite difference steady-state and transient analysis results. The results from this study indicate that water used as a secondary coolant can be designed to increase experimental test time, produce minimum venting of fluid and reduce overall development cost.
System design package for the solar heating and cooling central data processing system
NASA Technical Reports Server (NTRS)
1978-01-01
The central data processing system provides the resources required to assess the performance of solar heating and cooling systems installed at remote sites. These sites consist of residential, commercial, government, and educational types of buildings, and the solar heating and cooling systems can be hot-water, space heating, cooling, and combinations of these. The instrumentation data associated with these systems will vary according to the application and must be collected, processed, and presented in a form which supports continuity of performance evaluation across all applications. Overall software system requirements were established for use in the central integration facility which transforms raw data collected at remote sites into performance evaluation information for assessing the performance of solar heating and cooling systems.
Simulation study of air and water cooled photovoltaic panel using ANSYS
NASA Astrophysics Data System (ADS)
Syafiqah, Z.; Amin, N. A. M.; Irwan, Y. M.; Majid, M. S. A.; Aziz, N. A.
2017-10-01
Demand for alternative energy is growing due to decrease of fossil fuels sources. One of the promising and popular renewable energy technology is a photovoltaic (PV) technology. During the actual operation of PV cells, only around 15% of solar irradiance is converted to electricity, while the rest is converted into heat. The electrical efficiency decreases with the increment in PV panel’s temperature. This electrical energy is referring to the open-circuit voltage (Voc), short-circuit current (Isc) and output power generate. This paper examines and discusses the PV panel with water and air cooling system. The air cooling system was installed at the back of PV panel while water cooling system at front surface. The analyses of both cooling systems were done by using ANSYS CFX and PSPICE software. The highest temperature of PV panel without cooling system is 66.3 °C. There is a decrement of 19.2% and 53.2% in temperature with the air and water cooling system applied to PV panel.
He, Yingdong; Li, Nianping; Wang, Xiang; He, Meiling; He, De
2017-01-01
It is well known that personal cooling improves thermal comfort and save energy. This study aims to: (1) compare different personal cooling systems and (2) understand what influences users’ willingness to adopt them. A series of experiments on several types of personal cooling systems, which included physical measurements, questionnaires and feedback, was conducted in a real office environment. The obtained results showed that personal cooling improved comfort of participants in warm environments. Then an improved index was proposed and used to compare different types of personal cooling systems in terms of comfort and energy efficiency simultaneously. According to the improved index, desk fans were highly energy-efficient, while the hybrid personal cooling (the combination of radiant cooling desk and desk fan) consumed more energy but showed advantages of extending the comfortable temperature range. Moreover, if personal cooling was free, most participants were willing to adopt it and the effectiveness was the main factor influencing their willingness, whereas if participants had to pay, they probably refused to adopt it due to the cost and the availability of conventional air conditioners. Thus, providing effective and free personal cooling systems should be regarded as a better way for its wider application. PMID:29149078
Simulation of a 20-ton LiBr/H{sub 2}O absorption cooling system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wardono, B.; Nelson, R.M.
The possibility of using solar energy as the main heat input for cooling systems has led to several studies of available cooling technologies that use solar energy. The results show that double-effect absorption cooling systems give relatively high performance. To further study absorption cooling systems, a computer code was developed for a double-effect lithium bromide/water (LiBr/H{sub 2}O) absorption system. To evaluate the performance, two objective functions were developed including the coefficient of performance (COP) and the system cost. Based on the system cost, an optimization to find the minimum cost was performed to determine the nominal heat transfer areas ofmore » each heat exchanger. The nominal values of other system variables, such as the mass flow rates and inlet temperatures of the hot water, cooling water, and chilled water, are specified as commonly used values for commercial machines. The results of the optimization show that there are optimum heat transfer areas. In this study, hot water is used as the main energy input. Using a constant load of 20 tons cooling capacity, the effects of various variables including the heat transfer ares, mass flow rates, and inlet temperatures of hot water, cooling water, and chilled water are presented.« less
Cooling system having reduced mass pin fins for components in a gas turbine engine
Lee, Ching-Pang; Jiang, Nan; Marra, John J
2014-03-11
A cooling system having one or more pin fins with reduced mass for a gas turbine engine is disclosed. The cooling system may include one or more first surfaces defining at least a portion of the cooling system. The pin fin may extend from the surface defining the cooling system and may have a noncircular cross-section taken generally parallel to the surface and at least part of an outer surface of the cross-section forms at least a quartercircle. A downstream side of the pin fin may have a cavity to reduce mass, thereby creating a more efficient turbine airfoil.
High temperature cooling system and method
Loewen, Eric P.
2006-12-12
A method for cooling a heat source, a method for preventing chemical interaction between a vessel and a cooling composition therein, and a cooling system. The method for cooling employs a containment vessel with an oxidizable interior wall. The interior wall is oxidized to form an oxide barrier layer thereon, the cooling composition is monitored for excess oxidizing agent, and a reducing agent is provided to eliminate excess oxidation. The method for preventing chemical interaction between a vessel and a cooling composition involves introducing a sufficient quantity of a reactant which is reactive with the vessel in order to produce a barrier layer therein that is non-reactive with the cooling composition. The cooling system includes a containment vessel with oxidizing agent and reducing agent delivery conveyances and a monitor of oxidation and reduction states so that proper maintenance of a vessel wall oxidation layer occurs.
Cooling system with compressor bleed and ambient air for gas turbine engine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Marsh, Jan H.; Marra, John J.
A cooling system for a turbine engine for directing cooling fluids from a compressor to a turbine blade cooling fluid supply and from an ambient air source to the turbine blade cooling fluid supply to supply cooling fluids to one or more airfoils of a rotor assembly is disclosed. The cooling system may include a compressor bleed conduit extending from a compressor to the turbine blade cooling fluid supply that provides cooling fluid to at least one turbine blade. The compressor bleed conduit may include an upstream section and a downstream section whereby the upstream section exhausts compressed bleed airmore » through an outlet into the downstream section through which ambient air passes. The outlet of the upstream section may be generally aligned with a flow of ambient air flowing in the downstream section. As such, the compressed air increases the flow of ambient air to the turbine blade cooling fluid supply.« less
How gas cools (or, apples can fall up)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1987-01-01
This primer on gas cooling systems explains the basics of heat exchange within a refrigeration system, the principle of reverse-cycle refrigeration, and how a gas-engine-driven heat pump can provide cooling, additional winter heating capacity, and hot water year-round. Gas cooling equipment available or under development include natural gas chillers, engine-driven chillers, and absorption chillers. In cogeneration systems, heat recovered from an engine's exhaust and coolant may be used in an absorption chiller to provide air-conditioning. Gas desiccant cooling systems may be used in buildings and businesses that are sensitive to high humidity levels.
Evaporative cooling enhanced cold storage system
Carr, Peter
1991-01-01
The invention provides an evaporatively enhanced cold storage system wherein a warm air stream is cooled and the cooled air stream is thereafter passed into contact with a cold storage unit. Moisture is added to the cooled air stream prior to or during contact of the cooled air stream with the cold storage unit to effect enhanced cooling of the cold storage unit due to evaporation of all or a portion of the added moisture. Preferably at least a portion of the added moisture comprises water condensed during the cooling of the warm air stream.
Evaporative cooling enhanced cold storage system
Carr, P.
1991-10-15
The invention provides an evaporatively enhanced cold storage system wherein a warm air stream is cooled and the cooled air stream is thereafter passed into contact with a cold storage unit. Moisture is added to the cooled air stream prior to or during contact of the cooled air stream with the cold storage unit to effect enhanced cooling of the cold storage unit due to evaporation of all or a portion of the added moisture. Preferably at least a portion of the added moisture comprises water condensed during the cooling of the warm air stream. 3 figures.
Demonstration of an efficient cooling approach for SBIRS-Low
NASA Astrophysics Data System (ADS)
Nieczkoski, S. J.; Myers, E. A.
2002-05-01
The Space Based Infrared System-Low (SBIRS-Low) segment is a near-term Air Force program for developing and deploying a constellation of low-earth orbiting observation satellites with gimbaled optics cooled to cryogenic temperatures. The optical system design and requirements present unique challenges that make conventional cooling approaches both complicated and risky. The Cryocooler Interface System (CIS) provides a remote, efficient, and interference-free means of cooling the SBIRS-Low optics. Technology Applications Inc. (TAI), through a two-phase Small Business Innovative Research (SBIR) program with Air Force Research Laboratory (AFRL), has taken the CIS from initial concept feasibility through the design, build, and test of a prototype system. This paper presents the development and demonstration testing of the prototype CIS. Prototype system testing has demonstrated the high efficiency of this cooling approach, making it an attractive option for SBIRS-Low and other sensitive optical and detector systems that require low-impact cryogenic cooling.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kozubal, E.
2013-02-01
This presentation explains how liquid desiccant based coupled with an indirect evaporative cooler can efficiently produce cool, dry air, and how a liquid desiccant membrane air conditioner can efficiently provide cooling and dehumidification without the carryover problems of previous generations of liquid desiccant systems. It provides an overview to a liquid desiccant DX air conditioner that can efficiently provide cooling and dehumidification to high latent loads without the need for reheat, explains how liquid desiccant cooling and dehumidification systems can outperform vapor compression based air conditioning systems in hot and humid climates, explains how liquid desiccant cooling and dehumidification systemsmore » work, and describes a refrigerant free liquid desiccant based cooling system.« less
Sub-ambient non-evaporative fluid cooling with the sky
NASA Astrophysics Data System (ADS)
Goldstein, Eli A.; Raman, Aaswath P.; Fan, Shanhui
2017-09-01
Cooling systems consume 15% of electricity generated globally and account for 10% of global greenhouse gas emissions. With demand for cooling expected to grow tenfold by 2050, improving the efficiency of cooling systems is a critical part of the twenty-first-century energy challenge. Building upon recent demonstrations of daytime radiative sky cooling, here we demonstrate fluid cooling panels that harness radiative sky cooling to cool fluids below the air temperature with zero evaporative losses, and use almost no electricity. Over three days of testing, we show that the panels cool water up to 5 ∘C below the ambient air temperature at water flow rates of 0.2 l min-1 m-2, corresponding to an effective heat rejection flux of up to 70 W m-2. We further show through modelling that, when integrated on the condenser side of the cooling system of a two-storey office building in a hot dry climate (Las Vegas, USA), electricity consumption for cooling during the summer could be reduced by 21% (14.3 MWh).
Assessment of Natural Ventilation System for a Typical Residential House in Poland
NASA Astrophysics Data System (ADS)
Antczak-Jarząbska, Romana; Krzaczek, Marek
2016-09-01
The paper presents the research results of field measurements campaign of natural ventilation performance and effectiveness in a residential building. The building is located in the microclimate whose parameters differ significantly in relation to a representative weather station. The measurement system recorded climate parameters and the physical variables characterizing the air flow in the rooms within 14 days of the winter season. The measurement results showed that in spite of proper design and construction of the ventilation system, unfavorable microclimatic conditions that differed from the predicted ones caused significant reduction in the efficiency of the ventilation system. Also, during some time periods, external climate conditions caused an opposite air flow direction in the vent inlets and outlets, leading to a significant deterioration of air quality and thermal comfort measured by CO2 concentration and PMV index in a residential area.
NASA Astrophysics Data System (ADS)
Zhao, Rui; Gu, Junjie; Liu, Jie
2015-01-01
An effective battery thermal management (BTM) system is required for lithium-ion batteries to ensure a desirable operating temperature range with minimal temperature gradient, and thus to guarantee their high efficiency, long lifetime and great safety. In this paper, a heat pipe and wet cooling combined BTM system is developed to handle the thermal surge of lithium-ion batteries during high rate operations. The proposed BTM system relies on ultra-thin heat pipes which can efficiently transfer the heat from the battery sides to the cooling ends where the water evaporation process can rapidly dissipate the heat. Two sized battery packs, 3 Ah and 8 Ah, with different lengths of cooling ends are used and tested through a series high-intensity discharges in this study to examine the cooling effects of the combined BTM system, and its performance is compared with other four types of heat pipe involved BTM systems and natural convection cooling method. A combination of natural convection, fan cooling and wet cooling methods is also introduced to the heat pipe BTM system, which is able to control the temperature of battery pack in an appropriate temperature range with the minimum cost of energy and water spray.
Afrane, Yaw A.; Little, Tom J.; Lawson, Bernard W.; Githeko, Andrew K.
2008-01-01
We investigated the effects of deforestation on microclimates and sporogonic development of Plasmodium falciparum parasites in Anopheles gambiae mosquitoes in an area of the western Kenyan highland prone to malaria epidemics. An. gambiae mosquitoes were fed with P. falciparum–infected blood through membrane feeders. Fed mosquitoes were placed in houses in forested and deforested areas in a highland area (1,500 m above sea level) and monitored for parasite development. Deforested sites had higher temperatures and relative humidities, and the overall infection rate of mosquitoes was increased compared with that in forested sites. Sporozoites appeared on average 1.1 days earlier in deforested areas. Vectorial capacity was estimated to be 77.7% higher in the deforested site than in the forested site. We showed that deforestation changes microclimates, leading to more rapid sporogonic development of P. falciparum and to a marked increase of malaria risk in the western Kenyan highland. PMID:18826815
Biogeography of photoautotrophs in the high polar biome
Pointing, Stephen B.; Burkhard Büdel; Convey, Peter; Gillman, Len N.; Körner, Christian; Leuzinger, Sebastian; Vincent, Warwick F.
2015-01-01
The global latitudinal gradient in biodiversity weakens in the high polar biome and so an alternative explanation for distribution of Arctic and Antarctic photoautotrophs is required. Here we identify how temporal, microclimate and evolutionary drivers of biogeography are important, rather than the macroclimate features that drive plant diversity patterns elsewhere. High polar ecosystems are biologically unique, with a more central role for bryophytes, lichens and microbial photoautotrophs over that of vascular plants. Constraints on vascular plants arise mainly due to stature and ontogenetic barriers. Conversely non-vascular plant and microbial photoautotroph distribution is correlated with favorable microclimates and the capacity for poikilohydric dormancy. Contemporary distribution also depends on evolutionary history, with adaptive and dispersal traits as well as legacy influencing biogeography. We highlight the relevance of these findings to predicting future impacts on diversity of polar photoautotrophs and to the current status of plants in Arctic and Antarctic conservation policy frameworks. PMID:26442009
Merello, Paloma; García-Diego, Fernando-Juan; Zarzo, Manuel
2012-11-28
Ariadne's house, located at the city center of ancient Pompeii, is of great archaeological value due to the fresco paintings decorating several rooms. In order to assess the risks for long-term conservation affecting the valuable mural paintings, 26 temperature data-loggers and 26 relative humidity data-loggers were located in four rooms of the house for the monitoring of ambient conditions. Data recorded during 372 days were analyzed by means of graphical descriptive methods and analysis of variance (ANOVA). Results revealed an effect of the roof type and number of walls of the room. Excessive temperatures were observed during the summer in rooms covered with transparent roofs, and corrective actions were taken. Moreover, higher humidity values were recorded by sensors on the floor level. The present work provides guidelines about the type, number, calibration and position of thermohygrometric sensors recommended for the microclimate monitoring of mural paintings in outdoor or semi-confined environments.
Armstrong, Alona; Waldron, Susan; Whitaker, Jeanette; Ostle, Nicholas J
2014-01-01
Global energy demand is increasing as greenhouse gas driven climate change progresses, making renewable energy sources critical to future sustainable power provision. Land-based wind and solar electricity generation technologies are rapidly expanding, yet our understanding of their operational effects on biological carbon cycling in hosting ecosystems is limited. Wind turbines and photovoltaic panels can significantly change local ground-level climate by a magnitude that could affect the fundamental plant–soil processes that govern carbon dynamics. We believe that understanding the possible effects of changes in ground-level microclimates on these phenomena is crucial to reducing uncertainty of the true renewable energy carbon cost and to maximize beneficial effects. In this Opinions article, we examine the potential for the microclimatic effects of these land-based renewable energy sources to alter plant–soil carbon cycling, hypothesize likely effects and identify critical knowledge gaps for future carbon research. PMID:24132939
Kim, Young Bun; Oh, Jung Hun; McIver, Lauren J.; Rashkovetsky, Eugenia; Michalak, Katarzyna; Garner, Harold R.; Kang, Lin; Nevo, Eviatar; Korol, Abraham B.; Michalak, Pawel
2014-01-01
Repeat sequences, especially mobile elements, make up large portions of most eukaryotic genomes and provide enormous, albeit commonly underappreciated, evolutionary potential. We analyzed repeatomes of Drosophila melanogaster that have been diverging in response to a microclimate contrast in Evolution Canyon (Mount Carmel, Israel), a natural evolutionary laboratory with two abutting slopes at an average distance of only 200 m, which pose a constant ecological challenge to their local biotas. Flies inhabiting the colder and more humid north-facing slope carried about 6% more transposable elements than those from the hot and dry south-facing slope, in parallel to a suite of other genetic and phenotypic differences between the two populations. Nearly 50% of all mobile element insertions were slope unique, with many of them disrupting coding sequences of genes critical for cognition, olfaction, and thermotolerance, consistent with the observed patterns of thermotolerance differences and assortative mating. PMID:25006263
Kim, Young Bun; Oh, Jung Hun; McIver, Lauren J; Rashkovetsky, Eugenia; Michalak, Katarzyna; Garner, Harold R; Kang, Lin; Nevo, Eviatar; Korol, Abraham B; Michalak, Pawel
2014-07-22
Repeat sequences, especially mobile elements, make up large portions of most eukaryotic genomes and provide enormous, albeit commonly underappreciated, evolutionary potential. We analyzed repeatomes of Drosophila melanogaster that have been diverging in response to a microclimate contrast in Evolution Canyon (Mount Carmel, Israel), a natural evolutionary laboratory with two abutting slopes at an average distance of only 200 m, which pose a constant ecological challenge to their local biotas. Flies inhabiting the colder and more humid north-facing slope carried about 6% more transposable elements than those from the hot and dry south-facing slope, in parallel to a suite of other genetic and phenotypic differences between the two populations. Nearly 50% of all mobile element insertions were slope unique, with many of them disrupting coding sequences of genes critical for cognition, olfaction, and thermotolerance, consistent with the observed patterns of thermotolerance differences and assortative mating.
Use of CFD modelling for analysing air parameters in auditorium halls
NASA Astrophysics Data System (ADS)
Cichowicz, Robert
2017-11-01
Modelling with the use of numerical methods is currently the most popular method of solving scientific as well as engineering problems. Thanks to the use of computer methods it is possible for example to comprehensively describe the conditions in a given room and to determine thermal comfort, which is a complex issue including subjective sensations of the persons in a given room. The article presents the results of measurements and numerical computing that enabled carrying out the assessment of environment parameters, taking into consideration microclimate, temperature comfort, speeds in the zone of human presence and dustiness in auditory halls. For this purpose measurements of temperature, relative humidity and dustiness were made with the use of a digital microclimate meter and a laser dust particles counter. Thanks to the above by using the application DesignBuilder numerical computing was performed and the obtained results enabled determining PMV comfort indicator in selected rooms.
Small group gender ratios impact biology class performance and peer evaluations.
Sullivan, Lauren L; Ballen, Cissy J; Cotner, Sehoya
2018-01-01
Women are underrepresented in science, technology, engineering, and mathematics (STEM) disciplines. Evidence suggests the microclimate of the classroom is an important factor influencing female course grades and interest, which encourages retention of women in STEM fields. Here, we test whether the gender composition of small (8-9 person) learning groups impacts course performance, sense of social belonging, and intragroup peer evaluations of intellectual contributions. Across two undergraduate active learning courses in introductory biology, we manipulated the classroom microclimate by varying the gender ratios of learning groups, ranging from 0% female to 100% female. We found that as the percent of women in groups increased, so did overall course performance for all students, regardless of gender. Additionally, women assigned higher peer- evaluations in groups with more women than groups with less women. Our work demonstrates an added benefit of the retention of women in STEM: increased performance for all, and positive peer perceptions for women.
Measuring Evapotranspiration in Urban Irrigated Lawns in Two Kansas Cities
NASA Astrophysics Data System (ADS)
Shonkwiler, K. B.; Bremer, D.; Ham, J. M.
2011-12-01
Conservation of water is becoming increasingly critical in many metropolitan areas. The use of automated irrigation systems for the maintenance of lawns and landscapes is rising and these systems are typically maladjusted to apply more water than necessary, resulting in water wastage. Provision of accurate estimates of actual lawn water use may assist urbanites in conserving water through better adjustment of automatic irrigation systems. Micrometeorological methods may help determine actual lawn water use by measuring evapotranspiration (ET) from urban lawns. From April - August of 2011, four small tripod-mounted weather stations (tripods, five total) were deployed in twelve residential landscapes in the Kansas cities of Manhattan (MHK) and Wichita (ICT) in the USA (six properties in each city). Each tripod was instrumented to estimate reference crop evapotranspiration (ETo) via the FAO-56 method. During tripod deployment in residential lawns, actual evapotranspiration (ETactual) was measured nearby using a stationary, trailer-mounted eddy covariance (EC) station. The EC station sampled well-watered turf at the K-State Rocky Ford Turfgrass Center within 5 km of the study properties in MHK, and was also deployed at a commercial sod farm 15 - 40 km from the study residences in the greater ICT metro area. The fifth tripod was deployed in the source area of the EC station to estimate ETo in conjunction with tripods in the lawns (i.e., to serve as a reference). Data from EC allowed for computation of a so-called lawn coefficient (Kc) by determining the ratio of ETo from the tripods in residential lawns to ETo from the EC station (ETo,EC); hence, Kc = ETo,tripod / ETo,EC. Using this method, ETactual can be estimated for individual tripods within a lawn. Data suggests that it may be more accurate to quantify ET within individual lawns by microclimate (i.e., determine coefficients for "shaded" and "open/unshaded" portions of a lawn). By finding microclimate coefficients, estimates of ETactual for individual lawns can be tailored to the specific characteristics of each property.
NASA Astrophysics Data System (ADS)
Park, Sangki; Woo, Seungchul; Kim, Minho; Lee, Kihyung
2017-04-01
The design and evaluation of engine cooling and lubrication systems is generally based on real vehicle tests. Our goal here was to establish an engine heat balance model based on mathematical and interpretive analysis of each element of a passenger diesel engine cooling system using a 1-D numerical model. The purpose of this model is to determine ways of optimizing the cooling and lubrication components of an engine and then to apply these methods to actual cooling and lubrication systems of engines that will be developed in the future. Our model was operated under the New European Driving Cycle (NEDC) mode conditions, which represent the fuel economy evaluation mode in Europe. The flow rate of the cooling system was controlled using a control valve. Our results showed that the fuel efficiency was improved by as much as 1.23 %, cooling loss by 1.35 %, and friction loss by 2.21 % throughout NEDC modes by modification of control conditions.
Optimum design on refrigeration system of high-repetition-frequency laser
NASA Astrophysics Data System (ADS)
Li, Gang; Li, Li; Jin, Yezhou; Sun, Xinhua; Mao, Shaojuan; Wang, Yuanbo
2014-12-01
A refrigeration system with fluid cycle, semiconductor cooler and air cooler is designed to solve the problems of thermal lensing effect and unstable output of high-repetition-frequency solid-state lasers. Utilizing a circulating water pump, water recycling system carries the water into laser cavity to absorb the heat then get to water cooling head. The water cooling head compacts cold spot of semiconductor cooling chips, so the heat is carried to hot spot which contacts the radiating fins, then is expelled through cooling fan. Finally, the cooled water return to tank. The above processes circulate to achieve the purposes of highly effective refrigeration in miniative solid-state lasers.The refrigeration and temperature control components are designed strictly to ensure refrigeration effect and practicability. we also set up a experiment to test the performances of this refrigeration system, the results show that the relationship between water temperature and cooling power of semiconductor cooling chip is linear at 20°C-30°C (operating temperature range of Nd:YAG), the higher of the water temperature, the higher of cooling power. According to the results, cooling power of single semiconductor cooling chip is above 60W, and the total cooling power of three semiconductor cooling chips achieves 200W that will satisfy the refrigeration require of the miniative solid-state lasers.The performance parameters of laser pulse are also tested, include pulse waveform, spectrogram and laser spot. All of that indicate that this refrigeration system can ensure the output of high-repetition-frequency pulse whit high power and stability.
Small Scale Solar Cooling Unit in Climate Conditions of Latvia: Environmental and Economical Aspects
NASA Astrophysics Data System (ADS)
Jaunzems, Dzintars; Veidenbergs, Ivars
2010-01-01
The paper contributes to the analyses from the environmental and economical point of view of small scale solar cooling system in climate conditions of Latvia. Cost analyses show that buildings with a higher cooling load and full load hours have lower costs. For high internal gains, cooling costs are around 1,7 €/kWh and 2,5 €/kWh for buildings with lower internal gains. Despite the fact that solar cooling systems have significant potential to reduce CO2 emissions due to a reduction of electricity consumption, the economic feasibility and attractiveness of solar cooling system is still low.
Asetek's Warm-Water Liquid Cooling System Yields Energy Cost Savings at
NREL | Energy Systems Integration Facility | NREL Asetek Asetek's Warm-Water Liquid Cooling System Yields Energy Cost Savings at NREL Asetek's RackCDU liquid cooling system was installed and tested at the Energy Systems Integration Facility's (ESIF's) ultra-energy-efficient high-performance
Role of bacterial adhesion in the microbial ecology of biofilms in cooling tower systems.
Liu, Yang; Zhang, Wei; Sileika, Tadas; Warta, Richard; Cianciotto, Nicholas P; Packman, Aaron
2009-01-01
The fate of the three heterotrophic biofilm forming bacteria, Pseudomonas aeruginosa, Klebsiella pneumoniae and Flavobacterium sp. in pilot scale cooling towers was evaluated both by observing the persistence of each species in the recirculating water and the formation of biofilms on steel coupons placed in each cooling tower water reservoir. Two different cooling tower experiments were performed: a short-term study (6 days) to observe the initial bacterial colonization of the cooling tower, and a long-term study (3 months) to observe the ecological dynamics with repeated introduction of the test strains. An additional set of batch experiments (6 days) was carried out to evaluate the adhesion of each strain to steel surfaces under similar conditions to those found in the cooling tower experiments. Substantial differences were observed in the microbial communities that developed in the batch systems and cooling towers. P. aeruginosa showed a low degree of adherence to steel surfaces both in batch and in the cooling towers, but grew much faster than K. pneumoniae and Flavobacterium in mixed-species biofilms and ultimately became the dominant organism in the closed batch systems. However, the low degree of adherence caused P. aeruginosa to be rapidly washed out of the open cooling tower systems, and Flavobacterium became the dominant microorganism in the cooling towers in both the short-term and long-term experiments. These results indicate that adhesion, retention and growth on solid surfaces play important roles in the bacterial community that develops in cooling tower systems.
Role of bacterial adhesion in the microbial ecology of biofilms in cooling tower systems
Liu, Yang; Zhang, Wei; Sileika, Tadas; Warta, Richard; Cianciotto, Nicholas P.; Packman, Aaron
2009-01-01
The fate of the three heterotrophic biofilm forming bacteria, Pseudomonas aeruginosa, Klebsiella pneumoniae and Flavobacterium sp. in pilot scale cooling towers was evaluated both by observing the persistence of each species in the recirculating water and the formation of biofilms on steel coupons placed in each cooling tower water reservoir. Two different cooling tower experiments were performed: a short-term study (6 days) to observe the initial bacterial colonization of the cooling tower, and a long-term study (3 months) to observe the ecological dynamics with repeated introduction of the test strains. An additional set of batch experiments (6 days) was carried out to evaluate the adhesion of each strain to steel surfaces under similar conditions to those found in the cooling tower experiments. Substantial differences were observed in the microbial communities that developed in the batch systems and cooling towers. P. aeruginosa showed a low degree of adherence to steel surfaces both in batch and in the cooling towers, but grew much faster than K. pneumoniae and Flavobacterium in mixed-species biofilms and ultimately became the dominant organism in the closed batch systems. However, the low degree of adherence caused P. aeruginosa to be rapidly washed out of the open cooling tower systems, and Flavobacterium became the dominant microorganism in the cooling towers in both the short-term and long-term experiments. These results indicate that adhesion, retention and growth on solid surfaces play important roles in the bacterial community that develops in cooling tower systems. PMID:19177226
The 1984 NASA/ASEE summer faculty fellowship program
NASA Technical Reports Server (NTRS)
1984-01-01
The assessment of forest productivity and associated nitrogen flux in a number of conifer ecosystems is described. As a base line study of acid precipitation in the Sierra Nevada, involved is the extraction and integration of a number of data planes describing the terrain, soils, lithology, vegetation cover and structure, and microclimate of the region. The development of automated techniques to extract topographic networks (stream canyons and ridge lines) for use as a landscrape skeleton to organize and integrate data sets into an efficient geographical information system is examined. The software is written in both FORTRAN and C, and is portable to a number of different computer environments with minimal modification.
Biodegradable Plastic Mulch Films: Impacts on Soil Microbial Communities and Ecosystem Functions.
Bandopadhyay, Sreejata; Martin-Closas, Lluis; Pelacho, Ana M; DeBruyn, Jennifer M
2018-01-01
Agricultural plastic mulch films are widely used in specialty crop production systems because of their agronomic benefits. Biodegradable plastic mulches (BDMs) offer an environmentally sustainable alternative to conventional polyethylene (PE) mulch. Unlike PE films, which need to be removed after use, BDMs are tilled into soil where they are expected to biodegrade. However, there remains considerable uncertainty about long-term impacts of BDM incorporation on soil ecosystems. BDMs potentially influence soil microbial communities in two ways: first, as a surface barrier prior to soil incorporation, indirectly affecting soil microclimate and atmosphere (similar to PE films) and second, after soil incorporation, as a direct input of physical fragments, which add carbon, microorganisms, additives, and adherent chemicals. This review summarizes the current literature on impacts of plastic mulches on soil biological and biogeochemical processes, with a special emphasis on BDMs. The combined findings indicated that when used as a surface barrier, plastic mulches altered soil microbial community composition and functioning via microclimate modification, though the nature of these alterations varied between studies. In addition, BDM incorporation into soil can result in enhanced microbial activity and enrichment of fungal taxa. This suggests that despite the fact that total carbon input from BDMs is minuscule, a stimulatory effect on microbial activity may ultimately affect soil organic matter dynamics. To address the current knowledge gaps, long term studies and a better understanding of impacts of BDMs on nutrient biogeochemistry are needed. These are critical to evaluating BDMs as they relate to soil health and agroecosystem sustainability.
Waudby, Helen P; Petit, Sophie
2017-05-01
Deserts exhibit extreme climatic conditions. Small desert-dwelling vertebrates have physiological and behavioral adaptations to cope with these conditions, including the ability to seek shelter. We investigated the temperature (T) and relative humidity (RH) regulating properties of the soil cracks that characterize the extensive cracking-clay landscapes of arid Australia, and the extent of their use by 2 small marsupial species: fat-tailed and stripe-faced dunnarts (Sminthopsis crassicaudata and Sminthopsis macroura). We measured hourly (over 24-h periods) the T and RH of randomly-selected soil cracks compared to outside conditions, during 2 summers and 2 winters. We tracked 17 dunnarts (8 Sminthopsis crassicaudata and 9 Sminthopsis macroura) to quantify their use of cracks. Cracks consistently moderated microclimate, providing more stable conditions than available from non-crack points, which often displayed comparatively dramatic fluctuations in T and RH. Both dunnart species used crack shelters extensively. Cracks constitute important shelter for small animals during extreme conditions by providing a stable microclimate, which is typically cooler than outside conditions in summer and warmer in winter. Cracks likely play a fundamental sheltering role by sustaining the physiological needs of small mammal populations. Globally, cracking-clay areas are dominated by agricultural land uses, including livestock grazing. Management of these systems should focus not only on vegetation condition, but also on soil integrity, to maintain shelter resources for ground-dwelling fauna. © 2016 International Society of Zoological Sciences, Institute of Zoology/Chinese Academy of Sciences and John Wiley & Sons Australia, Ltd.
NASA Astrophysics Data System (ADS)
Tyapkov, V. F.; Chudakova, I. Yu.; Alekseenko, O. A.
2011-08-01
Ways of improving the water chemistry used in the turbine generator stator's cooling systems at Russian nuclear power plants are considered. Data obtained from operational chemical monitoring of indicators characterizing the quality of cooling water in the turbine generator stator cooling systems of operating power units at nuclear power plants are presented.
Characteristic Evaluation on Cooling Performance of Thermoelectric Modules.
Seo, Sae Rom; Han, Seungwoo
2015-10-01
The aim of this work is to develop a performance evaluation system for thermoelectric cooling modules. We describe the design of such a system, composed of a vacuum chamber with a heat sink along with a metal block to measure the absorbed heat Qc. The system has a simpler structure than existing water-cooled or air-cooled systems. The temperature difference between the cold and hot sides of the thermoelectric module ΔT can be accurately measured without any effects due to convection, and the temperature equilibrium time is minimized compared to a water-cooled system. The evaluation system described here can be used to measure characteristic curves of Qc as a function of ΔT, as well as the current-voltage relations. High-performance thermoelectric systems can therefore be developed using optimal modules evaluated with this system.
10 CFR Appendix A to Part 50 - General Design Criteria for Nuclear Power Plants
Code of Federal Regulations, 2012 CFR
2012-01-01
... Heat Removal 34 Emergency Core Cooling 35 Inspection of Emergency Core Cooling System 36 Testing of Emergency Core Cooling System 37 Containment Heat Removal 38 Inspection of Containment Heat Removal System 39 Testing of Containment Heat Removal System 40 Containment Atmosphere Cleanup 41 Inspection of...
10 CFR Appendix A to Part 50 - General Design Criteria for Nuclear Power Plants
Code of Federal Regulations, 2011 CFR
2011-01-01
... Heat Removal 34 Emergency Core Cooling 35 Inspection of Emergency Core Cooling System 36 Testing of Emergency Core Cooling System 37 Containment Heat Removal 38 Inspection of Containment Heat Removal System 39 Testing of Containment Heat Removal System 40 Containment Atmosphere Cleanup 41 Inspection of...
Corletti, Michael M.; Lau, Louis K.; Schulz, Terry L.
1993-01-01
The spent fuel pit of a pressured water reactor (PWR) nuclear power plant has sufficient coolant capacity that a safety rated cooling system is not required. A non-safety rated combined cooling and purification system with redundant branches selectively provides simultaneously cooling and purification for the spent fuel pit, the refueling cavity, and the refueling water storage tank, and transfers coolant from the refueling water storage tank to the refueling cavity without it passing through the reactor core. Skimmers on the suction piping of the combined cooling and purification system eliminate the need for separate skimmer circuits with dedicated pumps.
Human thermal comfort conditions and urban planning in hot-humid climates—The case of Cuba
NASA Astrophysics Data System (ADS)
Rodríguez Algeciras, José Abel; Coch, Helena; De la Paz Pérez, Guillermo; Chaos Yeras, Mabel; Matzarakis, Andreas
2016-08-01
Climate regional characteristics, urban environmental conditions, and outdoors thermal comfort requirements of residents are important for urban planning. Basic studies of urban microclimate can provide information and useful resources to predict and improve thermal conditions in hot-humid climatic regions. The paper analyzes the thermal bioclimate and its influence as urban design factor in Cuba, using Physiologically Equivalent Temperature (PET). Simulations of wind speed variations and shade conditions were performed to quantify changes in thermal bioclimate due to possible modifications in urban morphology. Climate data from Havana, Camagüey, and Santiago of Cuba for the period 2001 to 2012 were used to calculate PET with the RayMan model. The results show that changes in meteorological parameters influence the urban microclimate, and consequently modify the thermal conditions in outdoors spaces. Shade is the predominant strategy to improve urban microclimate with more significant benefits in terms of PET higher than 30 °C. For climatic regions such as the analyzed ones, human thermal comfort can be improved by a wind speed modification for thresholds of PET above 30 °C, and by a wind speed decreases in conditions below 26 °C. The improvement of human thermal conditions is crucial for urban sustainability. On this regards, our study is a contribution for urban designers, due to the possibility of taking advantage of results for improving microclimatic conditions based on urban forms. The results may enable urban planners to create spaces that people prefer to visit, and also are usable in the reconfiguration of cities.
Darby, Alexander; Draguljić, Danel; Glunk, Andrew; Gotsch, Sybil G
2016-10-01
Microclimate in the tropical montane cloud forest (TMCF) is variable on both spatial and temporal scales and can lead to large fluctuations in both leaf-level transpiration and whole plant water use. While variation in transpiration has been found in TMCFs, the influence of different microclimatic drivers on plant water relations in this ecosystem has been relatively understudied. Within the TMCF, epiphytes may be particularly affected by natural variation in microclimate due to their partial or complete disassociation from soil resources. In this study, we examined the effects of seasonal microclimate on whole plant water balance in epiphytes in both an observational and a manipulative experiment. We also evaluated the effects of different microclimatic drivers using three hierarchical linear (mixed) models. On average, 31 % of total positive sap flow was recovered via foliar water uptake (FWU) over the course of the study. We found that precipitation was the greatest driver of foliar water uptake and nighttime sap flow in our study species and that both VPD and precipitation were important drivers to daytime sap flow. We also found that despite adaptations to withstand seasonal drought, an extended dry period caused severe desiccation in most plants despite a large reduction in leaf-level and whole plant transpiration. Our results indicate that the epiphytes studied rely on FWU to maintain positive water balance in the dry season and that increases in dry periods in the TMCF may be detrimental to these common members of the epiphyte community.
Human thermal comfort conditions and urban planning in hot-humid climates-The case of Cuba.
Rodríguez Algeciras, José Abel; Coch, Helena; De la Paz Pérez, Guillermo; Chaos Yeras, Mabel; Matzarakis, Andreas
2016-08-01
Climate regional characteristics, urban environmental conditions, and outdoors thermal comfort requirements of residents are important for urban planning. Basic studies of urban microclimate can provide information and useful resources to predict and improve thermal conditions in hot-humid climatic regions. The paper analyzes the thermal bioclimate and its influence as urban design factor in Cuba, using Physiologically Equivalent Temperature (PET). Simulations of wind speed variations and shade conditions were performed to quantify changes in thermal bioclimate due to possible modifications in urban morphology. Climate data from Havana, Camagüey, and Santiago of Cuba for the period 2001 to 2012 were used to calculate PET with the RayMan model. The results show that changes in meteorological parameters influence the urban microclimate, and consequently modify the thermal conditions in outdoors spaces. Shade is the predominant strategy to improve urban microclimate with more significant benefits in terms of PET higher than 30 °C. For climatic regions such as the analyzed ones, human thermal comfort can be improved by a wind speed modification for thresholds of PET above 30 °C, and by a wind speed decreases in conditions below 26 °C. The improvement of human thermal conditions is crucial for urban sustainability. On this regards, our study is a contribution for urban designers, due to the possibility of taking advantage of results for improving microclimatic conditions based on urban forms. The results may enable urban planners to create spaces that people prefer to visit, and also are usable in the reconfiguration of cities.
The influence of mosquito resting behaviour and associated microclimate for malaria risk.
Paaijmans, Krijn P; Thomas, Matthew B
2011-07-07
The majority of the mosquito and parasite life-history traits that combine to determine malaria transmission intensity are temperature sensitive. In most cases, the process-based models used to estimate malaria risk and inform control and prevention strategies utilize measures of mean outdoor temperature. Evidence suggests, however, that certain malaria vectors can spend large parts of their adult life resting indoors. If significant proportions of mosquitoes are resting indoors and indoor conditions differ markedly from ambient conditions, simple use of outdoor temperatures will not provide reliable estimates of malaria transmission intensity. To date, few studies have quantified the differential effects of indoor vs outdoor temperatures explicitly, reflecting a lack of proper understanding of mosquito resting behaviour and associated microclimate. Published records from 8 village sites in East Africa revealed temperatures to be warmer indoors than outdoors and to generally show less daily variation. Exploring the effects of these temperatures on malaria parasite development rate suggested indoor-resting mosquitoes could transmit malaria between 0.3 and 22.5 days earlier than outdoor-resting mosquitoes. These differences translate to increases in transmission risk ranging from 5 to approaching 3,000%, relative to predictions based on outdoor temperatures. The pattern appears robust for low- and highland areas, with differences increasing with altitude. Differences in indoor vs outdoor environments lead to large differences in the limits and the intensity of malaria transmission. This finding highlights a need to better understand mosquito resting behaviour and the associated microclimate, and to broaden assessments of transmission ecology and risk to consider the potentially important role of endophily.
NASA Astrophysics Data System (ADS)
Duthie, L.; Hyslop, E.; Lee, M.; Phoenix, V.; Kennedy, C.
2009-04-01
The impact of our changing climate on the historic built environment of Scotland has received surprisingly little attention. Current projections indicate that Scotland will become notably wetter and warmer over the coming decades. Winter temperatures are predicted to increase by 30C with 15% more precipitation, one result should be more aggressive microbial weathering of the sandstone buildings. In order to understand better and to quantify the damage potentially caused, it is necessary to analyse existing microbial populations but also to characterize conditions within building stones, how they change over diurnal and seasonal cycles, and how they differ from external conditions. In this study, temperature, humidity and moisture sensors were inserted at different depths into representative Scottish sandstones to record parameters key to microbial colonisation and organic weathering. Penetration of photosynthetically active radiation has also been measured. The within-stone data were compared to meteorological conditions recorded by an adjacent weather station. These data have then been compared with analysis of the microbial populations at different depths within the stone, using osmium stained polished blocks. Notably, microbes occur up to 7 mm beneath the outer sandstone surface, with community structure differing with depth. Clearly, different communities experience very different conditions within the stone, reflecting trophic structure, light penetration and microclimate. The sensor data confirm that temperature and water availability all vary within the stone and differ considerably with the external environment. We conclude that the warm and humid microclimate within Scottish building stones promotes microbial colonisation and stone decay and both will increase significantly with the changing climate of Scotland and north-west Europe.
Gotsch, Sybil G; Davidson, Kenneth; Murray, Jessica G; Duarte, Vanessa J; Draguljić, Danel
2017-12-01
Tropical Montane Cloud Forests (TMCFs) are important ecosystems to study and preserve because of their high biodiversity and critical roles in local and regional ecosystem processes. TMCFs may be particularly affected by changes in climate because of the narrow bands of microclimate they occupy and the vulnerability of TMCF species to projected increases in cloud base heights and drought. A comprehensive understanding of the structure and function of TMCFs is lacking and difficult to attain because of variation in topography within and across TMCF sites. This causes large differences in microclimate and forest structure at both large and small scales. In this study, we estimated the abundance of the entire epiphyte community in the canopy (bryophytes, herbaceous vascular plants, woody epiphytes, and canopy dead organic matter) in six sites. In each of the sites we installed a complete canopy weather station to link epiphyte abundance to a number of microclimatic parameters. We found significant differences in epiphyte abundance across the sites; epiphyte abundance increased with elevation and leaf wetness, but decreased as vapor pressure deficit (VPD) increased. Epiphyte abundance had the strongest relationship with VPD; there were differences in VPD that could not be explained by elevation alone. By measuring this proxy of canopy VPD, TMCF researchers will better understand differences in microclimate and plant community composition across TMCF sites. Incorporating such information in comparative studies will allow for more meaningful comparisons across TMCFs and will further conservation and management efforts in this ecosystem. © 2017 Botanical Society of America.
Heat exchanger with auxiliary cooling system
Coleman, John H.
1980-01-01
A heat exchanger with an auxiliary cooling system capable of cooling a nuclear reactor should the normal cooling mechanism become inoperable. A cooling coil is disposed around vertical heat transfer tubes that carry secondary coolant therethrough and is located in a downward flow of primary coolant that passes in heat transfer relationship with both the cooling coil and the vertical heat transfer tubes. A third coolant is pumped through the cooling coil which absorbs heat from the primary coolant which increases the downward flow of the primary coolant thereby increasing the natural circulation of the primary coolant through the nuclear reactor.
On importance assessment of aging multi-state system
NASA Astrophysics Data System (ADS)
Frenkel, Ilia; Khvatskin, Lev; Lisnianski, Anatoly
2017-01-01
Modern high-tech equipment requires precise temperature control and effective cooling below the ambient temperature. Greater cooling efficiencies will allow equipment to be operated for longer periods without overheating, providing a greater return on investment and increased in availability of the equipment. This paper presents application of the Lz-transform method to importance assessment of aging multi-state water-cooling system used in one of Israeli hospitals. The water cooling system consists of 3 principal sub-systems: chillers, heat exchanger and pumps. The performance of the system and the sub-systems is measured by their produced cooling capacity. Heat exchanger is an aging component. Straightforward Markov method applied to solve this problem will require building of a system model with numerous numbers of states and solving a corresponding system of multiple differential equations. Lz-transform method, which is used for calculation of the system elements importance, drastically simplified the solution. Numerical example is presented to illustrate the described approach.
Passive cooling system for nuclear reactor containment structure
Gou, Perng-Fei; Wade, Gentry E.
1989-01-01
A passive cooling system for the contaminant structure of a nuclear reactor plant providing protection against overpressure within the containment attributable to inadvertent leakage or rupture of the system components. The cooling system utilizes natural convection for transferring heat imbalances and enables the discharge of irradiation free thermal energy to the atmosphere for heat disposal from the system.
Meier, R P H; Piller, V; Hagen, M E; Joliat, C; Buchs, J-B; Nastasi, A; Ruttimann, R; Buchs, N C; Moll, S; Vallée, J-P; Lazeyras, F; Morel, P; Bühler, L
2018-01-01
Robot-assisted kidney transplantation is feasible; however, concerns have been raised about possible increases in warm ischemia times. We describe a novel intra-abdominal cooling system to continuously cool the kidney during the procedure. Porcine kidneys were procured by standard open technique. Groups were as follows: Robotic renal transplantation with (n = 11) and without (n = 6) continuous intra-abdominal cooling and conventional open technique with intermittent 4°C saline cooling (n = 6). Renal cortex temperature, magnetic resonance imaging, and histology were analyzed. Robotic renal transplantation required a longer anastomosis time, either with or without the cooling system, compared to the open approach (70.4 ± 17.7 min and 74.0 ± 21.5 min vs. 48.7 ± 11.2 min, p-values < 0.05). The temperature was lower in the robotic group with cooling system compared to the open approach group (6.5 ± 3.1°C vs. 22.5 ± 6.5°C; p = 0.001) or compared to the robotic group without the cooling system (28.7 ± 3.3°C; p < 0.001). Magnetic resonance imaging parenchymal heterogeneities and histologic ischemia-reperfusion lesions were more severe in the robotic group without cooling than in the cooled (open and robotic) groups. Robot-assisted kidney transplantation prolongs the warm ischemia time of the donor kidney. We developed a novel intra-abdominal cooling system that suppresses the noncontrolled rewarming of donor kidneys during the transplant procedure and prevents ischemia-reperfusion injuries. © 2017 The Authors. American Journal of Transplantation published by Wiley Periodicals, Inc. on behalf of American Society of Transplant Surgeons.
A small scale CSP-based cooling system prototype (300W cooling capacity) and the system performance simulation tool will be developed as a proof of concept. Practical issues will be identified to improve our design.
Demonstration of the gypsy moth energy budget microclimate model
D. E. Anderson; D. R. Miller; W. E. Wallner
1991-01-01
The use of a "User friendly" version of "GMMICRO" model to quantify the local environment and resulting core temperature of GM larvae under different conditions of canopy defoliation, different forest sites, and different weather conditions was demonstrated.
Grape anthocyanin altered by absolute sunlight exclusion
USDA-ARS?s Scientific Manuscript database
This research was conducted to clarify anthocyanin accumulation within ‘Merlot’ grapes in response to microclimate, specifically to light incidence, temperature, and humidity. Treatment grape clusters were light-excluded during ripening by opaque white polypropylene enclosures, during which light in...
System and method for regulating EGR cooling using a Rankine cycle
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ernst, Timothy C.; Morris, Dave
This disclosure relates to a waste heat recovery (WHR) system and method for regulating exhaust gas recirculation (EGR) cooling, and more particularly, to a Rankine cycle WHR system and method, including a recuperator bypass arrangement to regulate EGR exhaust gas cooling for engine efficiency improvement and thermal management. This disclosure describes other unique bypass arrangements for increased flexibility in the ability to regulate EGR exhaust gas cooling.
System and method for regulating EGR cooling using a rankine cycle
Ernst, Timothy C.; Morris, Dave
2015-12-22
This disclosure relates to a waste heat recovery (WHR) system and method for regulating exhaust gas recirculation (EGR) cooling, and more particularly, to a Rankine cycle WHR system and method, including a recuperator bypass arrangement to regulate EGR exhaust gas cooling for engine efficiency improvement and thermal management. This disclosure describes other unique bypass arrangements for increased flexibility in the ability to regulate EGR exhaust gas cooling.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Andersson, B.
This paper will present the status of the development of district cooling systems in Scandinavia over the last 5 years. It will describe the technologies used in the systems that have been constructed as well as the options considered in different locations. It will identify the drivers for the development of the cooling business to-date, and what future drivers for a continuing development of district cooling in Sweden. To-date, approximately 25 different cities of varying sizes have completed feasibility studies to determine if district cooling is an attractive option. In a survey, that was conducted by the Swedish District Heatingmore » Association, some 25 cities expected to have district cooling systems in place by the year 2000. In Sweden, district heating systems with hot water is very common. In many cases, it is simply an addition to the current service for the district heating company to also supply district cooling to the building owners. A parallel from this can be drawn to North America where district cooling systems now are developing rapidly. I am convinced that in these cities a district heating service will be added as a natural expansion of the district cooling company`s service.« less
Active Control of Jets in Cross-Flow for Film Cooling Applications
NASA Technical Reports Server (NTRS)
Nikitopoulos, Dimitris E.
2003-01-01
Jets in cross-flow have applications in film cooling of gas turbine vanes, blades and combustor liners. Their cooling effectiveness depends on the extent to which the cool jet-fluid adheres to the cooled component surface. Lift-off of the cooling jet flow or other mechanisms promoting mixing, cause loss of cooling effectiveness as they allow the hot "free-stream" fluid to come in contact with the component surface. The premise of this project is that cooling effectiveness can be improved by actively controlling (e.9. forcing, pulsing) the jet flow. Active control can be applied to prevent/delay lift-off and suppress mixing. Furthermore, an actively controlled film-cooling system coupled with appropriate sensory input (e.g. temperature or heat flux) can adapt to spatial and temporal variations of the hot-gas path. Thus, it is conceivable that the efficiency of film-cooling systems can be improved, resulting in coolant fluid economy. It is envisioned that Micro Electro-Mechanical Systems (MEMS) will play a role in the realization of such systems. As a first step, a feasibility study will be conducted to evaluate the concept, identify actuation and sensory elements and develop a control strategy. Part of this study will be the design of a proof-of-concept experiment and collection of necessary data.
Thomas, Shalu; Ravishankaran, Sangamithra; Justin, N A Johnson Amala; Asokan, Aswin; Kalsingh, T Maria Jusler; Mathai, Manu Thomas; Valecha, Neena; Montgomery, Jacqui; Thomas, Matthew B; Eapen, Alex
2018-05-16
Environmental factors such as temperature, relative humidity and their daily variation influence a range of mosquito life history traits and hence, malaria transmission. The standard way of characterizing environmental factors with meteorological station data need not be the actual microclimates experienced by mosquitoes within local transmission settings. A year-long study was conducted in Chennai, India to characterize local temperature and relative humidity (RH). Data loggers (Hobos) were placed in a range of probable indoor and outdoor resting sites of Anopheles stephensi. Recordings were taken hourly to estimate mean temperature and RH, together with daily temperature range (DTR) and daily relative humidity range. The temperature data were used to explore the predicted variation in extrinsic incubation period (EIP) of Plasmodium falciparum and Plasmodium vivax between microhabitats and across the year. Mean daily temperatures within the indoor settings were significantly warmer than those recorded outdoors. DTR in indoor environments was observed to be modest and ranged from 2 to 6 °C. Differences in EIP between microhabitats were most notable during the hottest summer months of April-June, with parasite development predicted to be impaired for tiled houses and overhead tanks. Overall, the prevailing warm and stable conditions suggest rapid parasite development rate regardless of where mosquitoes might rest. Taking account of seasonal and local environmental variation, the predicted EIP of P. falciparum varied from a minimum of 9.1 days to a maximum of 15.3 days, while the EIP of P. vivax varied from 8.0 to 24.3 days. This study provides a detailed picture of the actual microclimates experienced by mosquitoes in an urban slum malaria setting. The data indicate differences between microhabitats that could impact mosquito and parasite life history traits. The predicted effects for EIP are often relatively subtle, but variation between minimum and maximum EIPs can play a role in disease transmission, depending on the time of year and where mosquitoes rest. Appropriate characterization of the local microclimate conditions would be the key to fully understand the effects of environment on local transmission ecology.
Hemodynamic and thermal responses to head and neck cooling in men and women
NASA Technical Reports Server (NTRS)
Ku, Y. T.; Montgomery, L. D.; Webbon, B. W.
1996-01-01
Personal cooling systems are used to alleviate symptoms of multiple sclerosis and to prevent increased core temperature during daily activities. The objective of this study was to determine the operating characteristics and the physiologic changes produced by short term use of one commercially available thermal control system. A Life Support Systems, Inc. Mark VII portable cooling system and a liquid cooling helmet were used to cool the head and neck regions of 12 female and 12 male subjects (25-55 yr) in this study. The healthy subjects, seated in an upright position at normal room temperature (approximately 21 degrees C), were tested for 30 min with the liquid cooling garment operated at its maximum cooling capacity. Electrocardiograms and scalp and intracranial blood flows were recorded periodically during each test sequence. Scalp, right and left ear, and oral temperatures and cooling system parameters were logged every 5 min. Scalp, right and left ear canal, and oral temperatures were all significantly (P <0.05) reduced by 30 min of head and neck cooling. Oral temperatures decreased approximately 0.2-0.6 degrees C after 30 min and continued to decrease further (approximately 0.1-0.2 degrees C) for a period of approximately 10 min after removal of the cooling helmet. Intracranial blood flow decreased significantly (P < 0.05) during the first 10 min of the cooling period. Both right and left ear temperatures in the women were significantly lower than those of the men during the cooling period. These data indicate that head and neck cooling may be used to reduce core temperature to that needed for symptomatic relief of both male and female multiple sclerosis patients. This study quantifies the operating characteristics of one liquid cooling garment as an example of the information needed to compare the efficiency of other garments operated under different test conditions.
Thibault, L; Beauséjour, A; Jacques, A; Ducas, E; Tremblay, M
2014-02-01
Many countries allow the overnight storage of whole blood (WB) at ambient temperature. Some countries, such as Canada, also require a rapid cooling of WB with an active cooling system. Given the significant operational constraints associated with current cooling systems, an alternative method for cooling and transporting WB at 20-24°C was evaluated. Phase 22 cooling packs (TCP Reliable Inc., USA) were used in combination with vacuum-insulated panel (VIP) boxes. Temperature profiles of simulated WB units were studied in extreme temperatures (-35 and 40°C). The quality of blood components prepared using Phase 22 packs and CompoCool-WB (Fresenius HemoCare, Germany) was studied. Phase 22 packs reduced the temperature of simulated WB bags from 37 to 24°C in 1·7 ± 0·2 h. Used in combination with VIP boxes, Phase 22 packs maintain the temperature of bags between 20 and 24°C for 15 and 24 h, compared to 2 and 11 h with CompoCool-WB, when exposed at -35 and 40°C, respectively. The quality of platelet concentrates and plasma was comparable, regardless of the cooling system used. For red blood cell units, per cent haemolysis on day 42 was slightly higher in products prepared after cooling with Phase 22 packs compared to CompoCool-WB (0·33 ± 0·15% vs. 0·21 ± 0·06%; P < 0·05). Phase 22 packs combined with VIP boxes are an acceptable alternative to butane-1,4-diol cooling systems. This system allows blood manufacturers to transport WB to processing facilities in a broad range of environmental conditions. © 2013 International Society of Blood Transfusion.
Potential Evaluation of Solar Heat Assisted Desiccant Hybrid Air Conditioning System
NASA Astrophysics Data System (ADS)
Tran, Thien Nha; Hamamoto, Yoshinori; Akisawa, Atsushi; Kashiwagi, Takao
The solar thermal driven desiccant dehumidification-absorption cooling hybrid system has superior advantage in hot-humid climate regions. The reasonable air processing of desiccant hybrid air conditioning system and the utility of clean and free energy make the system environment friendly and energy efficient. The study investigates the performance of the desiccant dehumidification air conditioning systems with solar thermal assistant. The investigation is performed for three cases which are combinations of solar thermal and absorption cooling systems with different heat supply temperature levels. Two solar thermal systems are used in the study: the flat plate collector (FPC) and the vacuum tube with compound parabolic concentrator (CPC). The single-effect and high energy efficient double-, triple-effect LiBr-water absorption cooling cycles are considered for cooling systems. COP of desiccant hybrid air conditioning systems are determined. The evaluation of these systems is subsequently performed. The single effect absorption cooling cycle combined with the flat plate collector solar system is found to be the most energy efficient air conditioning system.
Routine sampling and the control of Legionella spp. in cooling tower water systems.
Bentham, R H
2000-10-01
Cooling water samples from 31 cooling tower systems were cultured for Legionella over a 16-week summer period. The selected systems were known to be colonized by Legionella. Mean Legionella counts and standard deviations were calculated and time series correlograms prepared for each system. The standard deviations of Legionella counts in all the systems were very large, indicating great variability in the systems over the time period. Time series analyses demonstrated that in the majority of cases there was no significant relationship between the Legionella counts in the cooling tower at time of collection and the culture result once it was available. In the majority of systems (25/28), culture results from Legionella samples taken from the same systems 2 weeks apart were not statistically related. The data suggest that determinations of health risks from cooling towers cannot be reliably based upon single or infrequent Legionella tests.
NASA Astrophysics Data System (ADS)
Choi, M. K.; Morehouse, J. H.; Hughes, P. J.
1981-07-01
An analysis is performed of ground-coupled stand-alone and series configured solar-assisted liquid-to-air heat pump systems for residences. The year-round thermal performance of these systems for space heating, space cooling, and water heating is determined by simulation and compared against non-ground-coupled solar heat pump systems as well as conventional heating and cooling systems in three geographic locations: Washington, DC; Fort Worth, Texas; and Madison, Wisconsin. The results indicate that without tax credits a combined solar/ground-coupled heat pump system for space heating and cooling is not cost competitive with conventional systems. Its thermal performance is considerably better than non-ground-coupled solar heat pumps in Fort Worth. Though the ground-coupled stand-alone heat pump provides 51 percent of the heating and cooling load with non-purchased energy in Fort Worth, its thermal performance in Washington and Madison is poor.
Chien, S H; Hsieh, M K; Li, H; Monnell, J; Dzombak, D; Vidic, R
2012-02-01
Pilot-scale cooling towers can be used to evaluate corrosion, scaling, and biofouling control strategies when using particular cooling system makeup water and particular operating conditions. To study the potential for using a number of different impaired waters as makeup water, a pilot-scale system capable of generating 27,000 kJ∕h heat load and maintaining recirculating water flow with a Reynolds number of 1.92 × 10(4) was designed to study these critical processes under conditions that are similar to full-scale systems. The pilot-scale cooling tower was equipped with an automatic makeup water control system, automatic blowdown control system, semi-automatic biocide feeding system, and corrosion, scaling, and biofouling monitoring systems. Observed operational data revealed that the major operating parameters, including temperature change (6.6 °C), cycles of concentration (N = 4.6), water flow velocity (0.66 m∕s), and air mass velocity (3660 kg∕h m(2)), were controlled quite well for an extended period of time (up to 2 months). Overall, the performance of the pilot-scale cooling towers using treated municipal wastewater was shown to be suitable to study critical processes (corrosion, scaling, biofouling) and evaluate cooling water management strategies for makeup waters of complex quality.
24 CFR 3280.714 - Appliances, cooling.
Code of Federal Regulations, 2013 CFR
2013-04-01
... refrigerating systems serving any air conditioning or comfort-cooling system installed in a manufactured home... Systems § 3280.714 Appliances, cooling. (a) Every air conditioning unit or a combination air conditioning... Conditioning and Air Source Unitary Heat Pump Equipment and certified by ARI or other nationally recognized...
24 CFR 3280.714 - Appliances, cooling.
Code of Federal Regulations, 2012 CFR
2012-04-01
... refrigerating systems serving any air conditioning or comfort-cooling system installed in a manufactured home... Systems § 3280.714 Appliances, cooling. (a) Every air conditioning unit or a combination air conditioning... Conditioning and Air Source Unitary Heat Pump Equipment and certified by ARI or other nationally recognized...
30 CFR 36.47 - Tests of exhaust-gas cooling system.
Code of Federal Regulations, 2010 CFR
2010-07-01
... water consumption, high-water level when the system sprays excess water, and low-water level when the... cooling water shall be filled with the quantity of water recommended by the applicant. No cooling air... saturation, if this temperature is lower. (d) Water consumed in cooling the exhaust gas under the test...
Sleeve reaction chamber system
Northrup, M Allen [Berkeley, CA; Beeman, Barton V [San Mateo, CA; Benett, William J [Livermore, CA; Hadley, Dean R [Manteca, CA; Landre, Phoebe [Livermore, CA; Lehew, Stacy L [Livermore, CA; Krulevitch, Peter A [Pleasanton, CA
2009-08-25
A chemical reaction chamber system that combines devices such as doped polysilicon for heating, bulk silicon for convective cooling, and thermoelectric (TE) coolers to augment the heating and cooling rates of the reaction chamber or chambers. In addition the system includes non-silicon-based reaction chambers such as any high thermal conductivity material used in combination with a thermoelectric cooling mechanism (i.e., Peltier device). The heat contained in the thermally conductive part of the system can be used/reused to heat the device, thereby conserving energy and expediting the heating/cooling rates. The system combines a micromachined silicon reaction chamber, for example, with an additional module/device for augmented heating/cooling using the Peltier effect. This additional module is particularly useful in extreme environments (very hot or extremely cold) where augmented heating/cooling would be useful to speed up the thermal cycling rates. The chemical reaction chamber system has various applications for synthesis or processing of organic, inorganic, or biochemical reactions, including the polymerase chain reaction (PCR) and/or other DNA reactions, such as the ligase chain reaction.
User's manual for the BNW-I optimization code for dry-cooled power plants. [AMCIRC
DOE Office of Scientific and Technical Information (OSTI.GOV)
Braun, D.J.; Daniel, D.J.; De Mier, W.V.
1977-01-01
This appendix provides a listing, called Program AMCIRC, of the BNW-1 optimization code for determining, for a particular size power plant, the optimum dry cooling tower design using ammonia flow in the heat exchanger tubes. The optimum design is determined by repeating the design of the cooling system over a range of design conditions in order to find the cooling system with the smallest incremental cost. This is accomplished by varying five parameters of the plant and cooling system over ranges of values. These parameters are varied systematically according to techniques that perform pattern and gradient searches. The dry coolingmore » system optimized by program AMCIRC is composed of a condenser/reboiler (condensation of steam and boiling of ammonia), piping system (transports ammonia vapor out and ammonia liquid from the dry cooling towers), and circular tower system (vertical one-pass heat exchangers situated in circular configurations with cocurrent ammonia flow in the tubes of the heat exchanger). (LCL)« less
System design package for a solar heating and cooling system installed at Akron, Ohio
NASA Technical Reports Server (NTRS)
1979-01-01
Information used to evaluate the design of a solar heating, cooling, and domestic hot water system is given. A conventional heat pump provides summer cooling items as the design data brochure, system performance specification, system hazard analysis, spare parts list, and detailed design drawings. A solar system is installed in a single-family dwelling at Akron, Ohio, and at Duffield, Virginia.
Natural circulating passive cooling system for nuclear reactor containment structure
Gou, Perng-Fei; Wade, Gentry E.
1990-01-01
A passive cooling system for the contaminant structure of a nuclear reactor plant providing protection against overpressure within the containment attributable to inadvertent leakage or rupture of the system components. The cooling system utilizes natural convection for transferring heat imbalances and enables the discharge of irradiation free thermal energy to the atmosphere for heat disposal from the system.
Simulation of a double-effect LiBr/H{sub 2}O absorption cooling system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wardono, B.; Nelson, R.
1996-10-01
Since commercially-available, double-effect, absorption cooling systems give relatively high performance for using solar energy or other medium-temperature sources, their performance was simulated and studied. To evaluate the cooling system performance, two objective functions were established: the system performance (COP) and the system cost. The system cost was used as the objective function to determine the optimum design of the system, while the COP was used to evaluate the effects of each variable on the system performance. The system optimization shows that there is an economic optimum heat-transfer area for each heat exchanger. Further study shows that this is a globalmore » minimum cost of the system. The best COPs that could be achieved by changing the heat-transfer areas and the inlet hot water temperature vary between 1.4 and 1.5. Higher COPs of approximately 1.6 were achieved if higher chilled water inlet temperatures or lower cooling water temperatures are used. These conditions are not desirable since higher chilled water inlet temperatures are not useful for cooling, and lower cooling water inlet temperatures are not usually available.« less
Passive containment cooling water distribution device
Conway, Lawrence E.; Fanto, Susan V.
1994-01-01
A passive containment cooling system for a nuclear reactor containment vessel. Disclosed is a cooling water distribution system for introducing cooling water by gravity uniformly over the outer surface of a steel containment vessel using a series of radial guide elements and cascading weir boxes to collect and then distribute the cooling water into a series of distribution areas through a plurality of cascading weirs. The cooling water is then uniformly distributed over the curved surface by a plurality of weir notches in the face plate of the weir box.
Hybrid Geothermal Heat Pumps for Cooling Telecommunications Data Centers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beckers, Koenraad J; Zurmuhl, David P.; Lukawski, Maciej Z.
The technical and economic performance of geothermal heat pump (GHP) systems supplying year-round cooling to representative small data centers with cooling loads less than 500 kWth were analyzed and compared to air-source heat pumps (ASHPs). A numerical model was developed in TRNSYS software to simulate the operation of air-source and geothermal heat pumps with and without supplementary air cooled heat exchangers - dry coolers (DCs). The model was validated using data measured at an experimental geothermal system installed in Ithaca, NY, USA. The coefficient of performance (COP) and cooling capacity of the GHPs were calculated over a 20-year lifetime andmore » compared to the performance of ASHPs. The total cost of ownership (TCO) of each of the cooling systems was calculated to assess its economic performance. Both the length of the geothermal borehole heat exchangers (BHEs) and the dry cooler temperature set point were optimized to minimize the TCO of the geothermal systems. Lastly, a preliminary analysis of the performance of geothermal heat pumps for cooling dominated systems was performed for other locations including Dallas, TX, Sacramento, CA, and Minneapolis, MN.« less
NASA Technical Reports Server (NTRS)
Wetch, J. R.
1988-01-01
The objective was to determine which reactor, conversion, and radiator technologies would best fulfill future Megawatt Class Nuclear Space Power System Requirements. Specifically, the requirement was 10 megawatts for 5 years of full power operation and 10 years systems life on orbit. A variety of liquid metal and gas cooled reactors, static and dynamic conversion systems, and passive and dynamic radiators were considered. Four concepts were selected for more detailed study. The concepts are: a gas cooled reactor with closed cycle Brayton turbine-alternator conversion with heat pipe and pumped tube-fin heat rejection; a lithium cooled reactor with a free piston Stirling engine-linear alternator and a pumped tube-fin radiator; a lithium cooled reactor with potassium Rankine turbine-alternator and heat pipe radiator; and a lithium cooled incore thermionic static conversion reactor with a heat pipe radiator. The systems recommended for further development to meet a 10 megawatt long life requirement are the lithium cooled reactor with the K-Rankine conversion and heat pipe radiator, and the lithium cooled incore thermionic reactor with heat pipe radiator.
Liquid metal cooled nuclear reactor plant system
Hunsbedt, Anstein; Boardman, Charles E.
1993-01-01
A liquid metal cooled nuclear reactor having a passive cooling system for removing residual heat resulting for fuel decay during reactor shutdown, or heat produced during a mishap. The reactor system is enhanced with sealing means for excluding external air from contact with the liquid metal coolant leaking from the reactor vessel during an accident. The invention also includes a silo structure which resists attack by leaking liquid metal coolant, and an added unique cooling means.
Shiba, K; Toda, T; Iijima, S; Inoue, J; Yoshida, T; Cho, H; Kimura, M
1994-10-01
To develop an isoelectric focusing apparatus using a cellulose acetate membrane (Separax EF), we have designed a thermoelectric cooling isoelectric apparatus. This apparatus has two characteristics. Firstly, the cooling system was switched to a thermoelectric cooling system from an ice-cooling system. Secondly, the chamber lid of the electrophoretic apparatus was also devised so that samples could be applied without opening the chamber lid. With this apparatus we could perform the isoelectric focusing without worrying about room temperature and humidity in the laboratory. Applying 2000 V for an extra 5 min with our module cooling system, we achieved a much higher degree of resolution with three sheets of cellulose acetate membrane (Separax EF) overlaid for simultaneous electrophoresis. Thus, three types of information could be obtained from only one electrophoretic procedure.
NASA Astrophysics Data System (ADS)
Semple, Lucas M.; Carriveau, Rupp; Ting, David S.-K.
2018-04-01
In the Ontario greenhouse sector the misalignment of available solar radiation during the summer months and large heating demand during the winter months makes solar thermal collector systems an unviable option without some form of seasonal energy storage. Information obtained from Ontario greenhouse operators has shown that over 20% of annual natural gas usage occurs during the summer months for greenhouse pre-heating prior to sunrise. A transient model of the greenhouse microclimate and indoor conditioning systems is carried out using TRNSYS software and validated with actual natural gas usage data. A large-scale solar thermal collector system is then incorporated and found to reduce the annual heating energy demand by approximately 35%. The inclusion of the collector system correlates to a reduction of about 120 tonnes of CO2 equivalent emissions per acre of greenhouse per year. System payback period is discussed considering the benefits of a future Ontario carbon tax.
Corletti, M.M.; Lau, L.K.; Schulz, T.L.
1993-12-14
The spent fuel pit of a pressured water reactor (PWR) nuclear power plant has sufficient coolant capacity that a safety rated cooling system is not required. A non-safety rated combined cooling and purification system with redundant branches selectively provides simultaneously cooling and purification for the spent fuel pit, the refueling cavity, and the refueling water storage tank, and transfers coolant from the refueling water storage tank to the refueling cavity without it passing through the reactor core. Skimmers on the suction piping of the combined cooling and purification system eliminate the need for separate skimmer circuits with dedicated pumps. 1 figures.
Conduction cooling systems for linear accelerator cavities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kephart, Robert
A conduction cooling system for linear accelerator cavities. The system conducts heat from the cavities to a refrigeration unit using at least one cavity cooler interconnected with a cooling connector. The cavity cooler and cooling connector are both made from solid material having a very high thermal conductivity of approximately 1.times.10.sup.4 W m.sup.-1 K.sup.-1 at temperatures of approximately 4 degrees K. This allows for very simple and effective conduction of waste heat from the linear accelerator cavities to the cavity cooler, along the cooling connector, and thence to the refrigeration unit.
Hot gas path component cooling system
Lacy, Benjamin Paul; Bunker, Ronald Scott; Itzel, Gary Michael
2014-02-18
A cooling system for a hot gas path component is disclosed. The cooling system may include a component layer and a cover layer. The component layer may include a first inner surface and a second outer surface. The second outer surface may define a plurality of channels. The component layer may further define a plurality of passages extending generally between the first inner surface and the second outer surface. Each of the plurality of channels may be fluidly connected to at least one of the plurality of passages. The cover layer may be situated adjacent the second outer surface of the component layer. The plurality of passages may be configured to flow a cooling medium to the plurality of channels and provide impingement cooling to the cover layer. The plurality of channels may be configured to flow cooling medium therethrough, cooling the cover layer.
Biofouling reduction in recirculating cooling systems through biofiltration of process water.
Meesters, K P H; Van Groenestijn, J W; Gerritse, J
2003-02-01
Biofouling is a serious problem in industrial recirculating cooling systems. It damages equipment, through biocorrosion, and causes clogging and increased energy consumption, through decreased heat transfer. In this research a fixed-bed biofilter was developed which removed assimilable organic carbon (AOC) from process water, thus limiting the major substrate for the growth of biofouling. The biofilter was tested in a laboratory model recirculating cooling water system, including a heat exchanger and a cooling tower. A second identical model system without a biofilter served as a reference. Both installations were challenged with organic carbon (sucrose and yeast extract) to provoke biofouling. The biofilter improved the quality of the recirculating cooling water by reducing the AOC content, the ATP concentration, bacterial numbers (30-40 fold) and the turbidity (OD660). The process of biofouling in the heat exchangers, the process water pipelines and the cooling towers, was monitored by protein increase, heat transfer resistance, and chlorine demanded for maintenance. This revealed that biofouling was lower in the system with the biofilter compared to the reference installation. It was concluded that AOC removal through biofiltration provides an attractive, environmental-friendly means to reduce biofouling in industrial cooling systems.
NASA Astrophysics Data System (ADS)
Yin, Baoquan
2018-02-01
A new type of combined cooling, heating and power of photovoltaic radiant panel (PV/R) module was proposed, and applied in the zero energy buildings in this paper. The energy system of this building is composed of PV/R module, low temperature difference terminal, energy storage, multi-source heat pump, energy balance control system. Radiant panel is attached on the backside of the PV module for cooling the PV, which is called PV/R module. During the daytime, the PV module was cooled down with the radiant panel, as the temperature coefficient influence, the power efficiency was increased by 8% to 14%, the radiant panel solar heat collecting efficiency was about 45%. Through the nocturnal radiant cooling, the PV/R cooling capacity could be 50 W/m2. For the multifunction energy device, the system shows the versatility during the heating, cooling and power used of building utilization all year round.
NASA Astrophysics Data System (ADS)
Delucia, M.; Bronconi, R.; Carnevale, E.
1994-04-01
Gas turbine air cooling systems serve to raise performance to peak power levels during the hot months when high atmospheric temperatures cause reductions in net power output. This work describes the technical and economic advantages of providing a compressor inlet air cooling system to increase the gas turbine's power rating and reduce its heat rate. The pros and cons of state-of-the-art cooling technologies, i.e., absorption and compression refrigeration, with and without thermal energy storage, were examined in order to select the most suitable cooling solution. Heavy-duty gas turbine cogeneration systems with and without absorption units were modeled, as well as various industrial sectors, i.e., paper and pulp, pharmaceuticals, food processing, textiles, tanning, and building materials. The ambient temperature variations were modeled so the effects of climate could be accounted for in the simulation. The results validated the advantages of gas turbine cogeneration with absorption air cooling as compared to other systems without air cooling.
NASA Technical Reports Server (NTRS)
Namkoong, D.
1976-01-01
A three ton lithium bromide absorption water chiller was tested for a number of conditions involving hot water input, chilled water, and the cooling water. The primary influences on chiller capacity were the hot water inlet temperature and the cooling water inlet temperature. One combination of these two parameters extended the output to as much as 125% of design capacity, but no combination could lower the capacity to below 60% of design. A cooling system was conceptually designed so that it could provide several modes of operation. Such flexibility is needed for any solar cooling system to be able to accommodate the varying solar energy collection and the varying building demand. It was concluded that a three-ton absorption water chiller with the kind of performance that was measured can be incorporated into a cooling system such as that proposed, to provide efficient cooling over the specified ranges of operating conditions.
NASA Technical Reports Server (NTRS)
Namkoong, D.
1976-01-01
A 3-ton lithium bromide absorption water chiller was tested for a number of conditions involving hot-water input, chilled water, and the cooling water. The primary influences on chiller capacity were the hot water inlet temperature and the cooling water inlet temperature. One combination of these two parameters extended the output to as much as 125% of design capacity, but no combination could lower the capacity to below 60% of design. A cooling system was conceptually designed so that it could provide several modes of operation. Such flexibility is needed for any solar cooling system to be able to accommodate the varying solar energy collection and the varying building demand. It is concluded that a 3-ton absorption water chiller with the kind of performance that was measured can be incorporated into a cooling system such as that proposed, to provide efficient cooling over the specified ranges of operating conditions.
NASA Astrophysics Data System (ADS)
Alchapar, Noelia Liliana; Pezzuto, Claudia Cotrim; Correa, Erica Norma; Chebel Labaki, Lucila
2017-10-01
This paper describes different ways of reducing urban air temperature and their results in two cities: Campinas, Brazil—a warm temperate climate with a dry winter and hot summer (Cwa), and Mendoza, Argentina—a desert climate with cold steppe (BWk). A high-resolution microclimate modeling system—ENVI-met 3.1—was used to evaluate the thermal performance of an urban canyon in each city. A total of 18 scenarios were simulated including changes in the surface albedo, vegetation percentage, and the H/W aspect ratio of the urban canyons. These results revealed the same trend in behavior for each of the combinations of strategies evaluated in both cities. Nevertheless, these strategies produce a greater temperature reduction in the warm temperate climate (Cwa). Increasing the vegetation percentage reduces air temperatures and mean radiant temperatures in all scenarios. In addition, there is a greater decrease of urban temperature with the vegetation increase when the H/W aspect ratio is lower. Also, applying low albedo on vertical surfaces and high albedo on horizontal surfaces is successful in reducing air temperatures without raising the mean radiant temperature. The best combination of strategies—60 % of vegetation, low albedos on walls and high albedos on pavements and roofs, and 1.5 H/W—could reduce air temperatures up to 6.4 °C in Campinas and 3.5 °C in Mendoza.