Teeter, Matthew G; Langohr, G Daniel G; Medley, John B; Holdsworth, David W
2014-02-01
The purpose of this study was to determine the ability of micro-computed tomography to quantify wear in preclinical pin-on-plate testing of materials for use in joint arthroplasty. Wear testing of CoCr pins articulating against six polyetheretherketone plates was performed using a pin-on-plate apparatus over 2 million cycles. Change in volume due to wear was quantified with gravimetric analysis and with micro-computed tomography, and the volumes were compared. Separately, the volume of polyetheretherketone pin-on-plate specimens that had been soaking in fluid for 52 weeks was quantified with both gravimetric analysis and micro-computed tomography, and repeated after drying. The volume change with micro-computed tomography was compared to the mass change with gravimetric analysis. The mean wear volume measured was 8.02 ± 6.38 mm(3) with gravimetric analysis and 6.76 ± 5.38 mm(3) with micro-computed tomography (p = 0.06). Micro-computed tomography volume measurements did not show a statistically significant change with drying for either the plates (p = 0.60) or the pins (p = 0.09), yet drying had a significant effect on the gravimetric mass measurements for both the plates (p = 0.03) and the pins (p = 0.04). Micro-computed tomography provided accurate measurements of wear in polyetheretherketone pin-on-plate test specimens, and no statistically significant change was caused by fluid uptake. Micro-computed tomography quantifies wear depth and wear volume, mapped to the specific location of damage on the specimen, and is also capable of examining subsurface density as well as cracking. Its noncontact, nondestructive nature makes it ideal for preclinical testing of materials, in which further additional analysis techniques may be utilized.
Micro-computed tomography of pupal metamorphosis in the solitary bee Megachile rotundata
USDA-ARS?s Scientific Manuscript database
Insect metamorphosis involves a complex change in form and function, but most of these changes are internal and treated as a black box. In this study, we examined development of the solitary bee, Megachile rotundata, using micro-computed tomography (µCT) and digital volume analysis. We describe deve...
Hedberg, Elizabeth L; Kroese-Deutman, Henriette C; Shih, Charles K; Lemoine, Jeremy J; Liebschner, Michael A K; Miller, Michael J; Yasko, Alan W; Crowther, Roger S; Carney, Darrell H; Mikos, Antonios G; Jansen, John A
2005-01-01
This study focused on the assessment of radiography, microcomputed tomography, and histology for the evaluation of bone formation in a 15.0-mm defect in the rabbit radius after the implantation of a tissue-engineered construct. Radiography was found to be useful as a noninvasive method for obtaining images of calcified tissue throughout the time course of the experiment. With this method, however, image quality was low, making it difficult to obtain precise information about the location and quantity of the bone formed. Microcomputed tomography was used to create three-dimensional reconstructions of the bone (25-microm resolution). These reconstructions allowed for greater spatial resolution than the radiography, but did not allow for imaging of the implanted scaffold material or the surrounding, nonmineralized tissue. To visualize all materials within the defect area at the cellular level, histology was used. Histological analysis, however, is a destructive technique that did not allow for any further analysis of the samples. Each technique examined here has its own advantages and limitations, but each yields unique information regarding bone regeneration. It is only through the use of all three techniques that complete characterization of the bone growth and tissue/construct responses after implantation in vivo.
Robinson, Alan M; Stock, Stuart R; Soriano, Carmen; Xiao, Xianghui; Richter, Claus-Peter
2016-11-01
The aim of this study was to determine if X-ray micro-computed tomography could be used to locate and characterize tissue damage caused by laser irradiation and to describe its advantages over classical histology for this application. A surgical CO 2 laser, operated in single pulse mode (100 milliseconds) at different power settings, was used to ablate different types of cadaveric animal tissues. Tissue samples were then harvested and imaged with synchrotron X-ray phase-contrast and micro-computed tomography to generate stacks of virtual sections of the tissues. Subsequently, Fiji (ImageJ) software was used to locate tissue damage, then to quantify volumes of laser ablation cones and thermal coagulation damage from 3D renderings of tissue image stacks. Visual comparisons of tissue structures in X-ray images with those visible by classic light microscopy histology were made. We demonstrated that micro-computed tomography could be used to rapidly identify areas of surgical laser ablation, vacuolization, carbonization, and thermally coagulated tissue. Quantification and comparison of the ablation crater, which represents the volume of ablated tissue, and the thermal coagulation zone volumes were performed faster than we could by classical histology. We demonstrated that these procedures can be performed on fresh hydrated and non-sectioned plastic embedded tissue. We demonstrated that the application of non-destructive micro-computed tomography to the visualization and analysis of laser induced tissue damage without tissue sectioning is possible. This will improve evaluation of new surgical lasers and their corresponding effect on tissues. Lasers Surg. Med. 48:866-877, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Sawicka, Monika; Bedini, Rossella; Pecci, Raffaella; Pameijer, Cornelis Hans; Kmiec, Zbigniew
2012-01-01
The purpose of this study was to demonstrate potential application of micro-computed tomography in the morphometric analysis of the root resorption in extracted human first premolars subjected to the orthodontic force. In one patient treated in the orthodontic clinic two mandibular first premolars subjected to orthodontic force for 4 weeks and one control tooth were selected for micro-computed tomographic analysis. The hardware device used in this study was a desktop X-ray microfocus CT scanner (SkyScan 1072). The morphology of root's surfaces was assessed by TView and Computer Tomography Analyzer (CTAn) softwares (SkyScan, bvba) which allowed analysis of all microscans, identification of root resorption craters and measurement of their length, width and volume. Microscans showed in details the surface morphology of the investigated teeth. The analysis of microscans allowed to detect 3 root resorption cavities in each of the orthodontically moved tooth and only one resorption crater in the control tooth. The volumes of the resorption craters in orthodontically-treated teeth were much larger than in a control tooth. Micro-computed tomography is a reproducible technique for the three-dimensional non-invasive assessment of root's morphology ex vivo. TView and CTan softwares are useful in accurate morphometric measurements of root's resorption.
Micro-computed tomography imaging and analysis in developmental biology and toxicology.
Wise, L David; Winkelmann, Christopher T; Dogdas, Belma; Bagchi, Ansuman
2013-06-01
Micro-computed tomography (micro-CT) is a high resolution imaging technique that has expanded and strengthened in use since it was last reviewed in this journal in 2004. The technology has expanded to include more detailed analysis of bone, as well as soft tissues, by use of various contrast agents. It is increasingly applied to questions in developmental biology and developmental toxicology. Relatively high-throughput protocols now provide a powerful and efficient means to evaluate embryos and fetuses subjected to genetic manipulations or chemical exposures. This review provides an overview of the technology, including scanning, reconstruction, visualization, segmentation, and analysis of micro-CT generated images. This is followed by a review of more recent applications of the technology in some common laboratory species that highlight the diverse issues that can be addressed. Copyright © 2013 Wiley Periodicals, Inc.
Evaluation of a continuous-rotation, high-speed scanning protocol for micro-computed tomography.
Kerl, Hans Ulrich; Isaza, Cristina T; Boll, Hanne; Schambach, Sebastian J; Nolte, Ingo S; Groden, Christoph; Brockmann, Marc A
2011-01-01
Micro-computed tomography is used frequently in preclinical in vivo research. Limiting factors are radiation dose and long scan times. The purpose of the study was to compare a standard step-and-shoot to a continuous-rotation, high-speed scanning protocol. Micro-computed tomography of a lead grid phantom and a rat femur was performed using a step-and-shoot and a continuous-rotation protocol. Detail discriminability and image quality were assessed by 3 radiologists. The signal-to-noise ratio and the modulation transfer function were calculated, and volumetric analyses of the femur were performed. The radiation dose of the scan protocols was measured using thermoluminescence dosimeters. The 40-second continuous-rotation protocol allowed a detail discriminability comparable to the step-and-shoot protocol at significantly lower radiation doses. No marked differences in volumetric or qualitative analyses were observed. Continuous-rotation micro-computed tomography significantly reduces scanning time and radiation dose without relevantly reducing image quality compared with a normal step-and-shoot protocol.
Grace Sun; Rebecca E. Ibach; Meghan Faillace; Marek Gnatowski; Jessie A. Glaeser; John Haight
2016-01-01
After exposure in the field and laboratory soil block culture testing, the void content of woodâplastic composite (WPC) decking boards was compared to unexposed samples. A void volume analysis was conducted based on calculations of sample density and from micro-computed tomography (microCT) data. It was found that reference WPC contains voids of different sizes from...
Iglecias, Elaine Faga; Freire, Laila Gonzales; de Miranda Candeiro, George Táccio; Dos Santos, Marcelo; Antoniazzi, João Humberto; Gavini, Giulio
2017-04-01
The objective of this study was to assess the presence of voids in mesial root canals of mandibular molar teeth obturated by using the single-cone (SC) and continuous wave of condensation (CWC) obturation techniques, and results were analyzed by using micro-computed tomography. Twenty-four mandibular molars with fully developed roots and mesial root curvature ranging from 25° to 35° were instrumented by using Reciproc R25 files, and then they were obturated by using the SC and CWC techniques. Specimens were scanned before and after obturation for micro-computed tomography analysis (voxel size, 17.42 μm). After volumetric analysis and tridimensional reconstruction of the root canals, data were analyzed by using analysis of variance and the Tukey test. No significant differences were observed between the 2 techniques in terms of total percentage volume of voids: CWC = 3.91% ± 0.72%; SC = 6.52% ± 1.16% (P > .05). Only in the cervical third, CWC showed a significantly lower percentage of voids when compared with SC, namely 2.86% ± 0.94% vs 8.00% ± 1.86%, respectively (P < .05). The percentage volume of voids was similar in the 2 groups and was influenced by the obturation technique only in the cervical third. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Lau, S F; Wolschrijn, C F; Hazewinkel, H A W; Siebelt, M; Voorhout, G
2013-09-01
Medial coronoid disease (MCD) encompasses lesions of the entire medial coronoid process (MCP), both of the articular cartilage and the subchondral bone. To detect the earliest signs of MCD, radiography and computed tomography were used to monitor the development of MCD in 14 Labrador retrievers, from 6 to 7 weeks of age until euthanasia. The definitive diagnosis of MCD was based on necropsy and micro-computed tomography findings. The frequency of MCD in the dogs studied was 50%. Radiographic findings did not provide evidence of MCD, ulnar subtrochlear sclerosis or blunting of the cranial edge of the MCP. Computed tomography was more sensitive (30.8%) than radiography (0%) in detecting early MCD, with the earliest signs detectable at 14 weeks of age. A combination of the necropsy and micro-computed tomography findings of the MCP showed that MCD was manifested as a lesion of only the subchondral bone in dogs <18 weeks of age. In all dogs (affected and unaffected), there was close contact between the base of the MCP and the proximal radial head in the congruent joints. Computed tomography and micro-computed tomography findings indicated that the lesions of MCD probably originated at the base of the MCP. Copyright © 2013 Elsevier Ltd. All rights reserved.
Stavileci, Miranda; Hoxha, Veton; Görduysus, Ömer; Tatar, Ilkan; Laperre, Kjell; Hostens, Jeroen; Küçükkaya, Selen; Muhaxheri, Edmond
2015-01-01
Background Complete mechanical preparation of the root canal system is rarely achieved. Therefore, the purpose of this study was to evaluate and compare the root canal shaping efficacy of ProTaper rotary files and standard stainless steel K-files using micro-computed tomography. Material/Methods Sixty extracted upper second premolars were selected and divided into 2 groups of 30 teeth each. Before preparation, all samples were scanned by micro-computed tomography. Thirty teeth were prepared with the ProTaper system and the other 30 with stainless steel files. After preparation, the untouched surface and root canal straightening were evaluated with micro-computed tomography. The percentage of untouched root canal surface was calculated in the coronal, middle, and apical parts of the canal. We also calculated straightening of the canal after root canal preparation. Results from the 2 groups were statistically compared using the Minitab statistical package. Results ProTaper rotary files left less untouched root canal surface compared with manual preparation in coronal, middle, and apical sector (p<0.001). Similarly, there was a statistically significant difference in root canal straightening after preparation between the techniques (p<0.001). Conclusions Neither manual nor rotary techniques completely prepared the root canal, and both techniques caused slight straightening of the root canal. PMID:26092929
Stavileci, Miranda; Hoxha, Veton; Görduysus, Ömer; Tatar, Ilkan; Laperre, Kjell; Hostens, Jeroen; Küçükkaya, Selen; Muhaxheri, Edmond
2015-06-20
Complete mechanical preparation of the root canal system is rarely achieved. Therefore, the purpose of this study was to evaluate and compare the root canal shaping efficacy of ProTaper rotary files and standard stainless steel K-files using micro-computed tomography. Sixty extracted upper second premolars were selected and divided into 2 groups of 30 teeth each. Before preparation, all samples were scanned by micro-computed tomography. Thirty teeth were prepared with the ProTaper system and the other 30 with stainless steel files. After preparation, the untouched surface and root canal straightening were evaluated with micro-computed tomography. The percentage of untouched root canal surface was calculated in the coronal, middle, and apical parts of the canal. We also calculated straightening of the canal after root canal preparation. Results from the 2 groups were statistically compared using the Minitab statistical package. ProTaper rotary files left less untouched root canal surface compared with manual preparation in coronal, middle, and apical sector (p<0.001). Similarly, there was a statistically significant difference in root canal straightening after preparation between the techniques (p<0.001). Neither manual nor rotary techniques completely prepared the root canal, and both techniques caused slight straightening of the root canal.
Silva, Chinthaka M.; Snead, Lance Lewis; Hunn, John D.; ...
2015-08-03
X-ray microcomputed tomography (µCT) was applied in characterizing the internal structures of a number of irradiated materials, including carbon-carbon fibre composites, nuclear-grade graphite and tristructural isotropic-coated fuel particles. Local cracks in carbon-carbon fibre composites associated with their synthesis process were observed with µCT without any destructive sample preparation. Pore analysis of graphite samples was performed quantitatively, and qualitative analysis of pore distribution was accomplished. It was also shown that high-resolution µCT can be used to probe internal layer defects of tristructural isotropic-coated fuel particles to elucidate the resulting high release of radioisotopes. Layer defects of sizes ranging from 1 tomore » 5 µm and up could be isolated by to-mography. As an added advantage, µCT could also be used to identify regions with high densities of radioisotopes to deter-mine the proper plane and orientation of particle mounting for further analytical characterization, such as materialographic sectioning followed by optical and electron microscopy. Lastly, in fully ceramic matrix fuel forms, despite the highly absorbing matrix, characterization of tristructural isotropic-coated particles embedded in a silicon carbide matrix was accomplished usingµCT and related advanced image analysis techniques.« less
Kang, Sung-Won; Lee, Woo-Jin; Choi, Soon-Chul; Lee, Sam-Sun; Heo, Min-Suk; Huh, Kyung-Hoe; Kim, Tae-Il; Yi, Won-Jin
2015-03-01
We have developed a new method of segmenting the areas of absorbable implants and bone using region-based segmentation of micro-computed tomography (micro-CT) images, which allowed us to quantify volumetric bone-implant contact (VBIC) and volumetric absorption (VA). The simple threshold technique generally used in micro-CT analysis cannot be used to segment the areas of absorbable implants and bone. Instead, a region-based segmentation method, a region-labeling method, and subsequent morphological operations were successively applied to micro-CT images. The three-dimensional VBIC and VA of the absorbable implant were then calculated over the entire volume of the implant. Two-dimensional (2D) bone-implant contact (BIC) and bone area (BA) were also measured based on the conventional histomorphometric method. VA and VBIC increased significantly with as the healing period increased (p<0.05). VBIC values were significantly correlated with VA values (p<0.05) and with 2D BIC values (p<0.05). It is possible to quantify VBIC and VA for absorbable implants using micro-CT analysis using a region-based segmentation method.
Thali, Michael J; Taubenreuther, Ulrike; Karolczak, Marek; Braun, Marcel; Brueschweiler, Walter; Kalender, Willi A; Dirnhofer, Richard
2003-11-01
When a knife is stabbed in bone, it leaves an impression in the bone. The characteristics (shape, size, etc.) may indicate the type of tool used to produce the patterned injury in bone. Until now it has been impossible in forensic sciences to document such damage precisely and non-destructively. Micro-computed tomography (Micro-CT) offers an opportunity to analyze patterned injuries of tool marks made in bone. Using high-resolution Micro-CT and computer software, detailed analysis of three-dimensional (3D) architecture has recently become feasible and allows microstructural 3D bone information to be collected. With adequate viewing software, data from 2D slice of an arbitrary plane can be extracted from 3D datasets. Using such software as a "digital virtual knife," the examiner can interactively section and analyze the 3D sample. Analysis of the bone injury revealed that Micro-CT provides an opportunity to correlate a bone injury to an injury-causing instrument. Even broken knife tips can be graphically and non-destructively assigned to a suspect weapon.
Schulte, Friederike A; Lambers, Floor M; Mueller, Thomas L; Stauber, Martin; Müller, Ralph
2014-04-01
Time-lapsed in vivo micro-computed tomography is a powerful tool to analyse longitudinal changes in the bone micro-architecture. Registration can overcome problems associated with spatial misalignment between scans; however, it requires image interpolation which might affect the outcome of a subsequent bone morphometric analysis. The impact of the interpolation error itself, though, has not been quantified to date. Therefore, the purpose of this ex vivo study was to elaborate the effect of different interpolator schemes [nearest neighbour, tri-linear and B-spline (BSP)] on bone morphometric indices. None of the interpolator schemes led to significant differences between interpolated and non-interpolated images, with the lowest interpolation error found for BSPs (1.4%). Furthermore, depending on the interpolator, the processing order of registration, Gaussian filtration and binarisation played a role. Independent from the interpolator, the present findings suggest that the evaluation of bone morphometry should be done with images registered using greyscale information.
Gao, Yuan; Peters, Ove A; Wu, Hongkun; Zhou, Xuedong
2009-02-01
The purpose of this study was to customize an application framework by using the MeVisLab image processing and visualization platform for three-dimensional reconstruction and assessment of tooth and root canal morphology. One maxillary first molar was scanned before and after preparation with ProTaper by using micro-computed tomography. With a customized application framework based on MeVisLab, internal and external anatomy was reconstructed. Furthermore, the dimensions of root canal and radicular dentin were quantified, and effects of canal preparation were assessed. Finally, a virtual preparation with risk analysis was performed to simulate the removal of a broken instrument. This application framework provided an economical platform and met current requirements of endodontic research. The broad-based use of high-quality free software and the resulting exchange of experience might help to improve the quality of endodontic research with micro-computed tomography.
Inside marginal adaptation of crowns by X-ray micro-computed tomography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dos Santos, T. M.; Lima, I.; Lopes, R. T.
The objective of this work was to access dental arcade by using X-ray micro-computed tomography. For this purpose high resolution system was used and three groups were studied: Zirkonzahn CAD-CAM system, IPS e.max Press, and metal ceramic. The three systems assessed in this study showed results of marginal and discrepancy gaps clinically accepted. The great result of 2D and 3D evaluations showed that the used technique is a powerful method to investigate quantitative characteristics of dental arcade. (authors)
Study of Image Qualities From 6D Robot-Based CBCT Imaging System of Small Animal Irradiator.
Sharma, Sunil; Narayanasamy, Ganesh; Clarkson, Richard; Chao, Ming; Moros, Eduardo G; Zhang, Xin; Yan, Yulong; Boerma, Marjan; Paudel, Nava; Morrill, Steven; Corry, Peter; Griffin, Robert J
2017-01-01
To assess the quality of cone beam computed tomography images obtained by a robotic arm-based and image-guided small animal conformal radiation therapy device. The small animal conformal radiation therapy device is equipped with a 40 to 225 kV X-ray tube mounted on a custom made gantry, a 1024 × 1024 pixels flat panel detector (200 μm resolution), a programmable 6 degrees of freedom robot for cone beam computed tomography imaging and conformal delivery of radiation doses. A series of 2-dimensional radiographic projection images were recorded in cone beam mode by placing and rotating microcomputed tomography phantoms on the "palm' of the robotic arm. Reconstructed images were studied for image quality (spatial resolution, image uniformity, computed tomography number linearity, voxel noise, and artifacts). Geometric accuracy was measured to be 2% corresponding to 0.7 mm accuracy on a Shelley microcomputed tomography QA phantom. Qualitative resolution of reconstructed axial computed tomography slices using the resolution coils was within 200 μm. Quantitative spatial resolution was found to be 3.16 lp/mm. Uniformity of the system was measured within 34 Hounsfield unit on a QRM microcomputed tomography water phantom. Computed tomography numbers measured using the linearity plate were linear with material density ( R 2 > 0.995). Cone beam computed tomography images of the QRM multidisk phantom had minimal artifacts. Results showed that the small animal conformal radiation therapy device is capable of producing high-quality cone beam computed tomography images for precise and conformal small animal dose delivery. With its high-caliber imaging capabilities, the small animal conformal radiation therapy device is a powerful tool for small animal research.
NASA Astrophysics Data System (ADS)
Sinescu, Cosmin; Negrutiu, Meda; Topala, Florin; Ionita, Ciprian; Negru, Radu; Fabriky, Mihai; Marcauteanu, Corina; Bradu, Adrian; Dobre, George; Marsavina, Liviu; Rominu, Mihai; Podoleanu, Adrian
2011-10-01
Dental onlays are restorations used to repair rear teeth that have a mild to moderate amount of decay. They can also be used to restore teeth that are cracked or fractured if the damage is not severe enough to require a dental crown. The use of onlays requires less tooth reduction than does the use of metal fillings. This allows dentists to conserve more of a patient's natural tooth structure in the treatment process. The aims of this study are to evaluate the biomechanical comportment of the dental onlays, by using the 3D photo elasticity method and to investigate the integrity of the structures and their fitting to the dental support. For this optical coherence tomography and micro-computed tomography were employed. Both methods were used to investigate 37 dental onlays, 17 integral polymeric and 20 integral ceramic. The results permit to observe materials defects inside the ceramic or polymeric onlays situate in the biomechanically tensioned areas that could lead to fracture of the prosthetic structure. Marginal fitting problems of the onlays related to the teeth preparations were presented in order to observe the possibility of secondary cavities. The resulted images from the optical coherence tomography were verified by the micro-computed tomography. In conclusion, the optical coherence tomography can be used as a clinical method in order to evaluate the integrity of the dental ceramic and polymeric onlays and to investigate the quality of the marginal fitting to the teeth preparations.
Three Dimensional Cancellous Bone Structure in Hypoparathyroidism
Rubin, Mishaela R.; Dempster, David W.; Kohler, Thomas; Stauber, Martin; Zhou, Hua; Shane, Elizabeth; Nickolas, Thomas; Stein, Emily; Sliney, James; Silverberg, Shonni J.; Bilezikian, John P.; Müller, Ralph
2009-01-01
By conventional 2-dimensional histomorphometric analysis, we have shown that cancellous bone architecture is markedly altered in hypoparathyroidism. We have now extended these observations to a 3-dimensional analysis using microcomputed tomography. Percutaneous iliac crest bone biopsies were analyzed by high-resolution microcomputed tomography from the following 25 subjects with hypoparathyroidism: 5 postmenopausal women, 13 premenopausal women and 7 men. Thirteen living premenopausal healthy controls and 12 cadaver subjects without bone disease served as matched controls. Hypoparathyroid subjects had significantly greater bone surface density (BS/TV: 5.74 ± 4.7 vs. 3.73 ± 1.01 mm2/mm3 [mean ± SD]; p=0.04), trabecular thickness (Tb.Th: 0.25 ± 0.19 vs. 0.17 ± 0.04 mm; p=0.04), trabecular number (Tb.N: 2.99 ± 3.4 vs. 1.62 ± 0.39 mm−1; p=0.05) and connectivity density (Conn.D: 16.63 ± 18.7 vs. 8.39 ± 5.8 mm3; p=0.04) in comparison to matched controls. When an additional 8 hypoparathyorid (total n= 33) and 24 cadaver (total cadaver n= 36) subjects were added to the groups for an unmatched analysis, hypoparathyroid subjects had significantly greater cancellous bone volume (BV/TV: 26.98 ± 10 vs. 15.39 ± 4%; p< 0.001), , while trabecular separation (Tb.Sp: 0.642 ± 0.10 vs. 0.781 ± 0.13 mm; p<0.001) and estimation of the plate-rod characteristic (SMI: −0.457 ± 1.52 vs. 0.742 ± 0.51; p<0.001) were significantly lower, the latter observation implying a more plate-like trabecular structure. Variables of cancellous bone structure in the hypoparathyroid subjects, as assessed by microcomputed tomography, were highly correlated with those assessed by conventional histomorphometry. We conclude that cancellous bone in hypoparathyroidism is abnormal, suggesting that parathyroid hormone is required to maintain normal trabecular structure. The effect of these structural changes on bone strength remains to be determined. PMID:19782782
Kang, Sung-Won; Lee, Woo-Jin; Choi, Soon-Chul; Lee, Sam-Sun; Heo, Min-Suk; Huh, Kyung-Hoe
2015-01-01
Purpose We have developed a new method of segmenting the areas of absorbable implants and bone using region-based segmentation of micro-computed tomography (micro-CT) images, which allowed us to quantify volumetric bone-implant contact (VBIC) and volumetric absorption (VA). Materials and Methods The simple threshold technique generally used in micro-CT analysis cannot be used to segment the areas of absorbable implants and bone. Instead, a region-based segmentation method, a region-labeling method, and subsequent morphological operations were successively applied to micro-CT images. The three-dimensional VBIC and VA of the absorbable implant were then calculated over the entire volume of the implant. Two-dimensional (2D) bone-implant contact (BIC) and bone area (BA) were also measured based on the conventional histomorphometric method. Results VA and VBIC increased significantly with as the healing period increased (p<0.05). VBIC values were significantly correlated with VA values (p<0.05) and with 2D BIC values (p<0.05). Conclusion It is possible to quantify VBIC and VA for absorbable implants using micro-CT analysis using a region-based segmentation method. PMID:25793178
Bakhshalian, Neema; Freire, Marcelo; Min, Seiko; Wu, Ivy; Zadeh, Homayoun H
A total of 68 extraction sockets were grafted with anorganic bovine bone mineral and covered by dense polytetrafluoroethylene membrane. Quantitative analysis of three-dimensional microcomputed tomography imaging of core samples retrieved after a mean of 21.0 ± 14.2 weeks revealed 40.1% bone volume fraction (bone volume [BV]/total volume [TV]) and 12% residual graft. Evidence of de novo bone formation was observed in the form of discrete islands of newly formed bone in direct apposition to graft particles, separated from parent bone. Anterior sockets exhibited a significantly higher percentage of residual graft compared to premolar sockets (P = .05). The BV/TV and percentage of residual graft correlated well with histomorphometric analysis of the same sites, but not with implant outcomes.
Microcomputed tomography evaluation of white spot lesion remineralization with various procedures.
Kucuk, Eyup Burak; Malkoc, Siddik; Demir, Abdullah
2016-09-01
The aim of this study was to use microcomputed tomography to evaluate the effects on white spot lesions of 3 remineralizing agents compared with artificial saliva (Inonu University, Malatya, Turkey). The agents were GC Tooth Mousse (GC International, Itabashi-ku, Tokyo, Japan), 50-ppm sodium fluoride solution (Inonu University, Malatya, Turkey), and Clinpro 5000 (3M ESPE Dental Products (St Paul, Minn). The experimental and control teeth were stored in artificial saliva. Forty-four extracted premolars were divided into 4 groups of 11 teeth each (3 experimental groups and 1 control group). After white spot lesions were created on the teeth, a remineralizing agent was applied. Microcomputed tomography scanning was performed at the following times: T0 (sound enamel), T1 (day 0, when the white spot lesion was formed), T2 (day 15), and T3 (day 30). Volume, depth, surface area, and mineral density changes of the white spot lesions were evaluated at different time points using CTAn software (SkyScan; Bruker, Kontich, Belgium). GC Tooth Mousse and Clinpro 5000 improved all measurements after 30 days. However, Clinpro 5000 was not as effective in reducing lesion depth as it was in the other parameters. The artificial saliva group and the 50-ppm sodium fluoride solution did not show significant effects in the regression of the white spot lesions at the end of the 30-day experiment. GC Tooth Mousse and Clinpro 5000 were more effective in remineralization of white spot lesions than sodium fluoride solution and artificial saliva. They can be preferred for use clinically. Microcomputed tomography is a novel and effective method that shows promise in accurately evaluating white spot lesions and remineralization. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
Blank, Marissa C.; Roman, Brian B.; Henkelman, R. Mark; Millen, Kathleen J.
2012-01-01
The mammalian brain and skull develop concurrently in a coordinated manner, consistently producing a brain and skull that fit tightly together. It is common that abnormalities in one are associated with related abnormalities in the other. However, this is not always the case. A complete characterization of the relationship between brain and skull phenotypes is necessary to understand the mechanisms that cause them to be coordinated or divergent and to provide perspective on the potential diagnostic or prognostic significance of brain and skull phenotypes. We demonstrate the combined use of magnetic resonance imaging and microcomputed tomography for analysis of brain and skull phenotypes in the mouse. Co-registration of brain and skull images allows comparison of the relationship between phenotypes in the brain and those in the skull. We observe a close fit between the brain and skull of two genetic mouse models that both show abnormal brain and skull phenotypes. Application of these three-dimensional image analyses in a broader range of mouse mutants will provide a map of the relationships between brain and skull phenotypes generally and allow characterization of patterns of similarities and differences. PMID:22947655
Acar, Ahmet Hüseyin; Yolcu, Ümit; Gül, Mehmet; Keleş, Ali; Erdem, Necip Fazıl; Altundag Kahraman, Sevil
2015-04-01
The present study aimed to investigate the effectiveness of platelet-rich fibrin (PRF) on bone regeneration when used alone or in combination with hydroxyapatite (HA)/beta-tricalcium phosphate (βTCP). In this study, 20 New Zealand white rabbits were used and four calvarial defects were prepared in each animal. PRF, Straumann(®) Bone Ceramic (SBC), or PRF+SBC was applied to the defects; one defect was left untreated as a control. Ten rabbits were sacrificed at week 4 (T1) and 10 at week 8 (T2). After micro-computed tomography (micro-CT) scanning, the samples were sent for histological and histomorphometric analysis to evaluate and compare the volume and area of regenerated bone. Histomorphometric and micro-CT analysis showed that both PRF and SBC significantly increased bone regeneration at T1 and T2 (P<0.01). When PRF was used in combination with HA/βTCP, a further significant increase in new bone formation was observed at T1 and T2 compared with that when PRF or SBC was used alone (P<0.01). PRF has a positive effect on bone formation when used alone and in combination with HA/βTCP. Copyright © 2014 Elsevier Ltd. All rights reserved.
Quaranta, Alessandro; DʼIsidoro, Orlando; Bambini, Fabrizio; Putignano, Angelo
2016-02-01
To compare the available potential bone-implant contact (PBIC) area of standard and short dental implants by micro-computed tomography (μCT) assessment. Three short implants with different diameters (4.5 × 6 mm, 4.1 × 7 mm, and 4.1 × 6 mm) and 2 standard implants (3.5 × 10 mm and 3.3 × 9 mm) with diverse design and surface features were scanned with μCT. Cross-sectional images were obtained. Image data were manually processed to find the plane that corresponds to the most coronal contact point between the crestal bone and implant. The available PBIC was calculated for each sample. Later on, the cross-sectional slices were processed by a 3-dimensional (3D) software, and 3D images of each sample were used for descriptive analysis and display the microtopography and macrotopography. The wide-diameter short implant (4.5 × 6 mm) showed the higher PBIC (210.89 mm) value followed by the standard (178.07 mm and 185.37 mm) and short implants (130.70 mm and 110.70 mm). Wide-diameter short implants show a surface area comparable with standard implants. Micro-CT analysis is a promising technique to evaluate surface area in dental implants with different macrodesign, microdesign, and surface features.
Agger, Peter; Stephenson, Robert S; Dobrzynski, Halina; Atkinson, Andrew; Iaizzo, Paul A; Anderson, Robert H; Jarvis, Jonathan C; Allan, Sarah L; Partridge, John B; Zhao, Jichao; Zhang, Henggui; MacIver, David H
2016-10-01
The anatomical substrate for the mid-mural ventricular hyperechogenic zone remains uncertain, but it may represent no more than ultrasound reflected from cardiomyocytes orientated orthogonally to the ultrasonic beam. We sought to ascertain the relationship between the echogenic zone and the orientation of the cardiomyocytes. We used 3D echocardiography, diffusion tensor imaging, and microcomputed tomography to analyze the location and orientation of cardiomyocytes within the echogenic zone. We demonstrated that visualization of the echogenic zone is dependent on the position of the transducer and is most clearly seen from the apical window. Diffusion tensor imaging and microcomputed tomography show that the echogenic zone seen from the apical window corresponds to the position of the circumferentially orientated cardiomyocytes. An oblique band seen in the parasternal view relates to cardiomyocytes orientated orthogonally to the ultrasonic beam. The mid-mural ventricular hyperechogenic zone represents reflected ultrasound from cardiomyocytes aligned orthogonal to the ultrasonic beam. The echogenic zone does not represent a space, a connective tissue sheet, a boundary between ascending and descending limbs of a hypothetical helical ventricular myocardial band, nor an abrupt change in cardiomyocyte orientation. © 2016, Wiley Periodicals, Inc.
Mayer, Luciano; Gomes, Fernando Vacilotto; de Oliveira, Marília Gerhardt; de Moraes, João Feliz Duarte; Carlsson, Lennart
2016-12-01
The purpose of the present study is to evaluate the effects of low-level laser therapy on the osseointegration process by comparing resonance frequency analysis measurements performed at implant placement and after 30 days and micro-computed tomography images in irradiated vs nonirradiated rabbits. Fourteen male New Zealand rabbits were randomly divided into two groups of seven animals each, one control group (nonirradiated animals) and one experimental group that received low-level laser therapy (Thera Lase®, aluminum-gallium-arsenide laser diode, 10 J per spot, two spots per session, seven sessions, 830 nm, 50 mW, CW, Ø 0.0028 cm 2 ). The mandibular left incisor was surgically extracted in all animals, and one osseointegrated implant was placed immediately afterward (3.25ø × 11.5 mm; NanoTite, BIOMET 3i). Resonance frequency analysis was performed with the Osstell® device at implant placement and at 30 days (immediately before euthanasia). Micro-computed tomography analyses were then conducted using a high-resolution scanner (SkyScan 1172 X-ray Micro-CT) to evaluate the amount of newly formed bone around the implants. Irradiated animals showed significantly higher implant stability quotients at 30 days (64.286 ± 1.596; 95 % confidence interval (CI) 60.808-67.764) than controls (56.357 ± 1.596; 95 %CI 52.879-59.835) (P = .000). The percentage of newly formed bone around the implants was also significantly higher in irradiated animals (75.523 ± 8.510; 95 %CI 61.893-89.155) than in controls (55.012 ± 19.840; 95 %CI 41.380-68.643) (P = .027). Laser therapy, based on the irradiation protocol used in this study, was able to provide greater implant stability and increase the volume of peri-implant newly formed bone, indicating that laser irradiation effected an improvement in the osseointegration process.
Influence of peri-implant artifacts on bone morphometric analysis with micro-computed tomography.
Song, Jin Wook; Cha, Jung Yul; Bechtold, Till Edward; Park, Young Chel
2013-01-01
To determine the optimal dilation pixel size distance from the mini-implant interface needed to compensate for the metal artifact on micro-computed tomography (micro-CT) for bone morphometric analysis. A total of 72 self-drilling mini-implants were placed into the buccal alveolar bone of six male beagle dogs. After 12 weeks of orthodontic loading, specimens were harvested and scanned with micro-CT (Skyscan 1076) at a resolution of 9 μm. Using the reload plug-in and dilation procedure of CTAn, the percentage of bone-implant contact (BIC) and bone volume density (BV/TV, bone volume/total volume), respectively, were measured from one to seven pixels from the metal implant surface. Each pixel size of dilation (PSD) were compared with that of a ground histologic section, and the optimal PSD for bone morphometric analysis using micro-CT was determined. BIC values from micro-CT analysis decreased when the PSD increased (P < .05). BIC from micro-CT showed the highest correlation coefficient with BIC from histologic slides when the PSD was 5 to 7 (P < .05), whereas BV/TV from micro-CT showed a very high correlation with BV/TV from histologic slides in all ranges (P < .0001). To measure BIC and BV/TV using micro-CT, at least 5 PSD from the metal implant surface is needed.
Kim, Jo-Eun; Yi, Won-Jin; Heo, Min-Suk; Lee, Sam-Sun; Choi, Soon-Chul; Huh, Kyung-Hoe
2015-12-01
To evaluate the potential feasibility of cone beam computed tomography (CBCT) in the assessment of trabecular bone microarchitecture. Sixty-eight specimens from four pairs of human jaw were scanned using both micro-computed tomography (micro-CT) of 19.37-μm voxel size and CBCT of 100-μm voxel size. The correlation of 3-dimensional parameters between CBCT and micro-CT was evaluated. All parameters, except bone-specific surface and trabecular thickness, showed linear correlations between the 2 imaging modalities (P < .05). Among the parameters, bone volume, percent bone volume, trabecular separation, and degree of anisotropy (DA) of CBCT images showed strong correlations with those of micro-CT images. DA showed the strongest correlation (r = 0.693). Most microarchitectural parameters from CBCT were correlated with those from micro-CT. Some microarchitectural parameters, especially DA, could be used as strong predictors of bone quality in the human jaw. Copyright © 2015 Elsevier Inc. All rights reserved.
Koddenberg, Tim; Militz, Holger
2018-05-05
The popularity of X-ray based imaging methods has continued to increase in research domains. In wood research, X-ray micro-computed tomography (XμCT) is useful for structural studies examining the three-dimensional and complex xylem tissue of trees qualitatively and quantitatively. In this study, XμCT made it possible to visualize and quantify the spatial xylem organization of the angiosperm species Fraxinus excelsior L. on the microscopic level. Through image analysis, it was possible to determine morphological characteristics of the cellular axial tissue (vessel elements, fibers, and axial parenchyma cells) three-dimensionally. X-ray imaging at high resolutions provides very distinct visual insight into the xylem structure. Numerical analyses performed through semi-automatic procedures made it possible to quickly quantify cell characteristics (length, diameter, and volume of cells). Use of various spatial resolutions (0.87-5 μm) revealed boundaries users should be aware of. Nevertheless, our findings, both qualitative and quantitative, demonstrate XμCT to be a valuable tool for studying the spatial cell morphology of F. excelsior. Copyright © 2018. Published by Elsevier Ltd.
NASA Astrophysics Data System (ADS)
Mural, Prasanna Kumar S.; Jain, Shubham; Kumar, Sachin; Madras, Giridhar; Bose, Suryasarathi
2016-04-01
3D porous membranes were developed by etching one of the phases (here PEO, polyethylene oxide) from melt-mixed PE/PEO binary blends. Herein, we have systematically discussed the development of these membranes using X-ray micro-computed tomography. The 3D tomograms of the extruded strands and hot-pressed samples revealed a clear picture as to how the morphology develops and coarsens over a function of time during post-processing operations like compression molding. The coarsening of PE/PEO blends was traced using X-ray micro-computed tomography and scanning electron microscopy (SEM) of annealed blends at different times. It is now understood from X-ray micro-computed tomography that by the addition of a compatibilizer (here lightly maleated PE), a stable morphology can be visualized in 3D. In order to anchor biocidal graphene oxide sheets onto these 3D porous membranes, the PE membranes were chemically modified with acid/ethylene diamine treatment to anchor the GO sheets which were further confirmed by Fourier transform infrared spectroscopy (FTIR), X-ray photoelectron spectroscopy (XPS) and surface Raman mapping. The transport properties through the membrane clearly reveal unimpeded permeation of water which suggests that anchoring GO on to the membranes does not clog the pores. Antibacterial studies through the direct contact of bacteria with GO anchored PE membranes resulted in 99% of bacterial inactivation. The possible bacterial inactivation through physical disruption of the bacterial cell wall and/or reactive oxygen species (ROS) is discussed herein. Thus this study opens new avenues in designing polyolefin based antibacterial 3D porous membranes for water purification.3D porous membranes were developed by etching one of the phases (here PEO, polyethylene oxide) from melt-mixed PE/PEO binary blends. Herein, we have systematically discussed the development of these membranes using X-ray micro-computed tomography. The 3D tomograms of the extruded strands and hot-pressed samples revealed a clear picture as to how the morphology develops and coarsens over a function of time during post-processing operations like compression molding. The coarsening of PE/PEO blends was traced using X-ray micro-computed tomography and scanning electron microscopy (SEM) of annealed blends at different times. It is now understood from X-ray micro-computed tomography that by the addition of a compatibilizer (here lightly maleated PE), a stable morphology can be visualized in 3D. In order to anchor biocidal graphene oxide sheets onto these 3D porous membranes, the PE membranes were chemically modified with acid/ethylene diamine treatment to anchor the GO sheets which were further confirmed by Fourier transform infrared spectroscopy (FTIR), X-ray photoelectron spectroscopy (XPS) and surface Raman mapping. The transport properties through the membrane clearly reveal unimpeded permeation of water which suggests that anchoring GO on to the membranes does not clog the pores. Antibacterial studies through the direct contact of bacteria with GO anchored PE membranes resulted in 99% of bacterial inactivation. The possible bacterial inactivation through physical disruption of the bacterial cell wall and/or reactive oxygen species (ROS) is discussed herein. Thus this study opens new avenues in designing polyolefin based antibacterial 3D porous membranes for water purification. Electronic supplementary information (ESI) available: SEM micrographs of porous PE with and without maleated PE, X-ray micro-computed tomogram of porous extruded PE, FTIR spectra of GO, XPS wide spectra of untreated and GO immobilized PE and Raman spectra of PE and GO. See DOI: 10.1039/c6nr01356b
Zhao, Dan; Shen, Ya; Peng, Bin; Haapasalo, Markus
2013-03-01
The aim of this study was to describe the canal shaping properties of Hyflex CM, Twisted Files (TF), and K3 rotary nickel-titanium files by using micro-computed tomography in maxillary first molars. A total of 36 mesiobuccal root canals of maxillary first molars were prepared with Hyflex CM, TF, or K3 system. Micro-computed tomography was used to scan the specimens before and after instrumentation. The volume of untreated canal, volume of dentin removed after preparation, amount of uninstrumented area, and the transportation for the coronal, middle, and apical thirds of canals were measured. Instrumentation of canals increased their volume and surface area. TF group showed the greatest amount of volumetric dentin removal (P < .05), whereas no significant difference was found in Hyflex CM and K3 groups. There were no significant differences among instrument types concerning uninstrumented area. The TF system produced significantly less transportation than the K3 system in the apical third of canals. No significant difference was found between TF and Hyflex CM instruments relating to apical transportation. In vitro, Hyflex and TF instruments shaped curved root canals in maxillary first molar without significant shaping errors. Crown Copyright © 2013. Published by Elsevier Inc. All rights reserved.
Geometric analysis of maxillary first premolar prepared by two nickel-titanium rotary instruments.
Al-Sudani, Dina; Almalki, Majed; Al-Shahrani, Saad; Ahlquist, Michael
2014-03-01
The present study was conducted with the aim of evaluating and comparing the shaping ability of two Nickel-titanium rotary instruments, with two disparate design features, on root canal geometry of extracted human maxillary first premolars using microcomputed tomography. Twenty four bifurcated maxillary first premolars were divided into two groups and embedded in a rubber-based impression material. Both groups were submitted to micro-computed tomography before and after canal preparation (buccal and palatal) with either ProFile Vortex or Revo-S rotary instruments. Images were reconstructed and cross-sections corresponding to a distance 1, 2, 3, 4, 5, 6, and 7 mm from the anatomical apex were selected for canal transportation analysis. Volume changes were also measured. The degree and direction of canal transportation were non-significant for both instruments. Statistically significant differences were observed only between levels in the buccal canal in both groups. There was no significant difference between the two rotary systems in regards to the volume of dentin removed. Our findings showed that ProFile Vortex and Revo-S instruments respected the original root canal anatomy and behaved similarly. ProFile Vortex rotary systems produced with innovative process were concluded to shape the upper maxillary premolar by leading minimal canal transportation, similar to Revo-S, rotary systems produced from traditional process.
Micro-computed tomography of false starts produced on bone by different hand-saws.
Pelletti, Guido; Viel, Guido; Fais, Paolo; Viero, Alessia; Visentin, Sindi; Miotto, Diego; Montisci, Massimo; Cecchetto, Giovanni; Giraudo, Chiara
2017-05-01
The analysis of macro- and microscopic characteristics of saw marks on bones can provide useful information about the class of the tool utilized to produce the injury. The aim of the present study was to test micro-computed tomography (micro-CT) for the analysis of false starts experimentally produced on 32 human bone sections using 4 different hand-saws in order to verify the potential utility of micro-CT for distinguishing false starts produced by different saws and to correlate the morphology of the tool with that of the bone mark. Each sample was analysed through stereomicroscopy and micro-CT. Stereomicroscopic analysis allowed the identification of the false starts and the detection of the number of tool marks left by each saw. Micro-CT scans, through the integration of 3D renders and multiplanar reconstructions (MPR), allowed the identification of the shape of each false start correlating it to the injuring tool. Our results suggest that micro-CT could be a useful technique for assessing false starts produced by different classes of saws, providing accurate morphological profiles of the bone marks with all the advantages of high resolution 3D imaging (e.g., high accuracy, non-destructive analysis, preservation and documentation of evidence). However, further studies are necessary to integrate qualitative data with quantitative metrical analysis in order to further characterize the false start and the related injuring tool. Copyright © 2017 Elsevier B.V. All rights reserved.
Particle-induced osteolysis in three-dimensional micro-computed tomography.
Wedemeyer, Christian; Xu, Jie; Neuerburg, Carl; Landgraeber, Stefan; Malyar, Nasser M; von Knoch, Fabian; Gosheger, Georg; von Knoch, Marius; Löer, Franz; Saxler, Guido
2007-11-01
Small-animal models are useful for the in vivo study of particle-induced osteolysis, the most frequent cause of aseptic loosening after total joint replacement. Microstructural changes associated with particle-induced osteolysis have been extensively explored using two-dimensional (2D) techniques. However, relatively little is known regarding the 3D dynamic microstructure of particle-induced osteolysis. Therefore, we tested micro-computed tomography (micro-CT) as a novel tool for 3D analysis of wear debris-mediated osteolysis in a small-animal model of particle-induced osteolysis. The murine calvarial model based on polyethylene particles was utilized in 14 C57BL/J6 mice randomly divided into two groups. Group 1 received sham surgery, and group 2 was treated with polyethylene particles. We performed 3D micro-CT analysis and histological assessment. Various bone morphometric parameters were assessed. Regression was used to examine the relation between the results achieved by the two methods. Micro-CT analysis provides a fully automated means to quantify bone destruction in a mouse model of particle-induced osteolysis. This method revealed that the osteolytic lesions in calvaria in the experimental group were affected irregularly compared to the rather even distribution of osteolysis in the control group. This is an observation which would have been missed if histomorphometric analysis only had been performed, leading to false assessment of the actual situation. These irregularities seen by micro-CT analysis provide new insight into individual bone changes which might otherwise be overlooked by histological analysis and can be used as baseline information on which future studies can be designed.
Campbell, Graeme M; Sophocleous, Antonia
2014-01-01
Micro-computed tomography (micro-CT) is a high-resolution imaging modality that is capable of analysing bone structure with a voxel size on the order of 10 μm. With the development of in vivo micro-CT, where disease progression and treatment can be monitored in a living animal over a period of time, this modality has become a standard tool for preclinical assessment of bone architecture during disease progression and treatment. For meaningful comparison between micro-CT studies, it is essential that the same parameters for data acquisition and analysis methods be used. This protocol outlines the common procedures that are currently used for sample preparation, scanning, reconstruction and analysis in micro-CT studies. Scan and analysis methods for trabecular and cortical bone are covered for the femur, tibia, vertebra and the full neonate body of small rodents. The analysis procedures using the software provided by ScancoMedical and Bruker are discussed, and the routinely used bone architectural parameters are outlined. This protocol also provides a section dedicated to in vivo scanning and analysis, which covers the topics of anaesthesia, radiation dose and image registration. Because of the expanding research using micro-CT to study other skeletal sites, as well as soft tissues, we also provide a review of current techniques to examine the skull and mandible, adipose tissue, vasculature, tumour severity and cartilage. Lists of recommended further reading and literature references are included to provide the reader with more detail on the methods described. PMID:25184037
Hochberg, Uri; Albuquerque, Caetano; Rachmilevitch, Shimon; Cochard, Herve; David-Schwartz, Rakefet; Brodersen, Craig R; McElrone, Andrew; Windt, Carel W
2016-09-01
The 'hydraulic vulnerability segmentation' hypothesis predicts that expendable distal organs are more susceptible to water stress-induced embolism than the main stem of the plant. In the current work, we present the first in vivo visualization of this phenomenon. In two separate experiments, using magnetic resonance imaging or synchrotron-based microcomputed tomography, grapevines (Vitis vinifera) were dehydrated while simultaneously scanning the main stems and petioles for the occurrence of emboli at different xylem pressures (Ψx ). Magnetic resonance imaging revealed that 50% of the conductive xylem area of the petioles was embolized at a Ψx of -1.54 MPa, whereas the stems did not reach similar losses until -1.9 MPa. Microcomputed tomography confirmed these findings, showing that approximately half the vessels in the petioles were embolized at a Ψx of -1.6 MPa, whereas only few were embolized in the stems. Petioles were shown to be more resistant to water stress-induced embolism than previously measured with invasive hydraulic methods. The results provide the first direct evidence for the hydraulic vulnerability segmentation hypothesis and highlight its importance in grapevine responses to severe water stress. Additionally, these data suggest that air entry through the petiole into the stem is unlikely in grapevines during drought. © 2015 John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Iwasaki, Shinya; Inoue, Mayuri; Suzuki, Atsushi; Sasaki, Osamu; Kano, Harumasa; Iguchi, Akira; Sakai, Kazuhiko; Kawahata, Hodaka
2016-09-01
Symbiotic algae of primary polyps play an important role in calcification of coral skeletons. However, the function of the symbiotic algae, including the way they influence the physical features of their host skeleton under various conditions, is not well understood. We used X-ray microcomputed tomography to observe skeletal shape characteristics in symbiotic and aposymbiotic primary polyps of Acropora digitifera that were cultured at various temperature and pCO2 levels (temperature 27, 29, 33°C; pCO2 400, 800, 1000 µatm). Symbiotic polyps had a basal plate with a well-developed folding margin supporting the branched skeleton, whereas aposymbiotic ones did not. The features of the folding margin suggest that it might be the initial growth stage of the epitheca. In addition, three-dimensional (3-D) morphological measurements made by X-ray microcomputed tomography show that the branched skeletons of symbiotic primary polyps were taller than those of aposymbiotic ones, suggesting that zooxanthellae in coral primary polyps play a critical role in the height growth of skeletal branches. Furthermore, results of the temperature- and pCO2-controlled experiments suggest that global warming might greatly affect the activity of zooxanthellae, whereas ocean acidification might reduce calcification by damaging the coral host itself. Our findings provide new knowledge about the role of zooxanthellae in coral calcification.
Chiesura, Gabriele; Luyckx, Geert; Voet, Eli; Lammens, Nicolas; Van Paepegem, Wim; Degrieck, Joris; Dierick, Manuel; Van Hoorebeke, Luc; Vanderniepen, Pieter; Sulejmani, Sanne; Sonnenfeld, Camille; Geernaert, Thomas; Berghmans, Francis
2015-01-01
Quality of embedment of optical fibre sensors in carbon fibre-reinforced polymers plays an important role in the resultant properties of the composite, as well as for the correct monitoring of the structure. Therefore, availability of a tool able to check the optical fibre sensor-composite interaction becomes essential. High-resolution 3D X-ray Micro-Computed Tomography, or Micro-CT, is a relatively new non-destructive inspection technique which enables investigations of the internal structure of a sample without actually compromising its integrity. In this work the feasibility of inspecting the position, the orientation and, more generally, the quality of the embedment of an optical fibre sensor in a carbon fibre reinforced laminate at unit cell level have been proven. PMID:25961383
Schouten, Corinne; Meijer, Gert J; van den Beucken, Jeroen J J P; Spauwen, Paul H M; Jansen, John A
2009-09-01
In the present study, the effects of implant design and surface properties on peri-implant bone response were evaluated with both conventional histomorphometry and micro-computed tomography (micro-CT), using two geometrically different dental implants (Screw type, St; Push-in, Pi) either or not surface-modified (non-coated, CaP-coated, or CaP-coated+TGF-beta1). After 12 weeks of implantation in a goat femoral condyle model, peri-implant bone response was evaluated in three different zones (inner: 0-500 microm; middle: 500-1000 microm; and outer: 1000-1500 microm) around the implant. Results indicated superiority of conventional histomorphometry over micro-CT, as the latter is hampered by deficits in the discrimination at the implant/tissue interface. Beyond this interface, both analysis techniques can be regarded as complementary. Histomorphometrical analysis showed an overall higher bone volume around St compared to Pi implants, but no effects of surface modification were observed. St implants showed lowest bone volumes in the outer zone, whereas inner zones were lowest for Pi implants. These results implicate that for Pi implants bone formation started from two different directions (contact- and distance osteogenesis). For St implants it was concluded that undersized implantation technique and loosening of bone fragments compress the zones for contact and distant osteogenesis, thereby improving bone volume at the interface significantly.
Alberich-Bayarri, Angel; Moratal, David; Ivirico, Jorge L Escobar; Rodríguez Hernández, José C; Vallés-Lluch, Ana; Martí-Bonmatí, Luis; Estellés, Jorge Más; Mano, Joao F; Pradas, Manuel Monleón; Ribelles, José L Gómez; Salmerón-Sánchez, Manuel
2009-10-01
Detailed knowledge of the porous architecture of synthetic scaffolds for tissue engineering, their mechanical properties, and their interrelationship was obtained in a nondestructive manner. Image analysis of microcomputed tomography (microCT) sections of different scaffolds was done. The three-dimensional (3D) reconstruction of the scaffold allows one to quantify scaffold porosity, including pore size, pore distribution, and struts' thickness. The porous morphology and porosity as calculated from microCT by image analysis agrees with that obtained experimentally by scanning electron microscopy and physically measured porosity, respectively. Furthermore, the mechanical properties of the scaffold were evaluated by making use of finite element modeling (FEM) in which the compression stress-strain test is simulated on the 3D structure reconstructed from the microCT sections. Elastic modulus as calculated from FEM is in agreement with those obtained from the stress-strain experimental test. The method was applied on qualitatively different porous structures (interconnected channels and spheres) with different chemical compositions (that lead to different elastic modulus of the base material) suitable for tissue regeneration. The elastic properties of the constructs are explained on the basis of the FEM model that supports the main mechanical conclusion of the experimental results: the elastic modulus does not depend on the geometric characteristics of the pore (pore size, interconnection throat size) but only on the total porosity of the scaffold. (c) 2009 Wiley Periodicals, Inc.
Evaluation of fixation of expandable implants in the mandibles of ovariectomized sheep.
Xiao, Jian-Rui; Li, De-Hua; Chen, Yu-Xuan; Chen, Shu-Jun; Guan, Su-Min; Kong, Liang
2013-04-01
This study aimed to investigate the effects of an expandable implant (EI) in ovariectomized sheep. The EI and taper implant (control group) were produced and placed in mandibles of ovariectomized sheep. Twelve weeks after implantation, resonance frequency analysis, biomechanical tests, histomorphometry, and micro-computed tomography were applied to detect the osseointegration in the 2 groups. The implant stability quotient values, maximal pullout forces, and bone-implant contact (BIC) were 60.3 ± 7.9, 511.0 ± 18.7 N, and 53.14% ± 4.56%, respectively, in the EI group and 58.3 ± 8.9, 394.5 ± 54.5 N, and 46.85% ± 5.04%, respectively, in the control group. There was no significant difference between the 2 groups in implant stability quotient values (P > .05); however, in the EI group the maximal pullout force and BIC were increased significantly (P < .05 and P < .01, respectively). Micro-computed tomography analysis showed that the bone volume/total volume ratio and trabecular number increased significantly (P < .01) and trabecular separation decreased significantly (P < .05) in the EI group. EI could improve osseointegration in osteoporosis after 12 weeks of implantation by increasing BIC around the implant and by supplying an extra osseointegration surface. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Auersvald, Caroline Moreira; Santos, Felipe Rychuv; Nakano, Mayara Mytie; Leoni, Graziela Bianchi; de Sousa Neto, Manoel Damião; Scariot, Rafaela; Giovanini, Allan Fernando; Deliberador, Tatiana Miranda
2017-07-01
To evaluate the effect of a single-dose local administration of PTH on bone healing in rat calvarial bone defects by means of micro-computed tomography, histological and histomorphometric analysis. Critical-size cranial osteotomy defects were created in 42 male rats. The animals were randomly divided into 3 groups. In the C Group, the bone defect was only filled with a blood clot. In the S Group, it was filled with a collagen sponge and covered with bovine cortical membrane. In the PTH Group, the defect was filled with a collagen sponge soaked with PTH and covered with bovine cortical membrane. The groups were further split in two for euthanasia 15 and 60days post-surgery. Data was statistically analyzed with t-tests for independent samples or the nonparametric Mann-Whitney test when applicable. Intragroup comparisons were analyzed with paired t-tests (p<0.05). Micro-CT analysis results did not demonstrate statistically significant intergroup differences. At 15days post-surgery, the histomorphometric analysis showed that the PTH Group exhibited a significantly higher percentage of bone formation compared with the S Group. At 60days post-surgery, a higher percentage of new bone was observed in the PTH group. The results suggest that the local administration of PTH encouraged the bone healing in critical-size calvarial defects in rats. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Minamino, Takuya; Mine, Atsushi; Matsumoto, Mariko; Sugawa, Yoshihiko; Kabetani, Tomoshige; Higashi, Mami; Kawaguchi, Asuka; Ohmi, Masato; Awazu, Kunio; Yatani, Hirofumi
2015-10-01
No previous reports have observed inside the root canal using both optical coherence tomography (OCT) and x-ray microcomputed tomography (μCT) for the same sample. The purpose of this study was to clarify both OCT and μCT image properties from observations of the same root canal after resin core build-up treatment. As OCT allows real-time observation of samples, gap formation may be able to be shown in real time. A dual-cure, one-step, self-etch adhesive system bonding agent, and dual-cure resin composite core material were used in root canals in accordance with instructions from the manufacturer. The resulting OCT images were superior for identifying gap formation at the interface, while μCT images were better to grasp the tooth form. Continuous tomographic images from real-time OCT observation allowed successful construction of a video of the resin core build-up procedure. After 10 to 12 s of light curing, a gap with a clear new signal occurred at the root-core material interface, proceeding from the coronal side (6 mm from the cemento-enamel junction) to the apical side of the root.
The Role of Peripheral Nerve Function in Age-Related Bone Loss and Changes in Bone Adaptation
2013-10-01
mechanical loading (months 6-18): 2a. Strain gage analysis of bone strain during tibial compression (months 6-7) 2b. Capsaicin or vehicle treatment...of neonatal mice (months 6-8) 2c. Tibial compression of capsaicin- and vehicle-injected mice (months 8-10) 2d. Micro-computed tomography of mouse...the endosteal and periosteal surfaces. Capsaicin treatment altered bone formation rate parameters in the tibias of treated mice (Table 2). There
Chan, Emmanuel; Dalci, Oyku; Petocz, Peter; Papadopoulou, Alexandra K; Darendeliler, M Ali
2018-02-01
Studies have demonstrated the potential efficacy of micro-osteoperforations in accelerating tooth movement by amplifying the expression of inflammatory markers. The aim of this investigation was to examine the effects of micro-osteoperforations on orthodontic root resorption with microcomputed tomography. This prospective controlled clinical trial involved 20 subjects requiring extraction of the maxillary first premolars as part of their orthodontic treatment. A buccal tipping force of 150 g was applied to both premolars. Using the Propel appliance (Propel Orthodontics, San Jose, Calif), micro-osteoperforations were applied at a depth of 5 mm on the mesial and distal aspects in the midroot region of the experimental side of the first premolar root; the contralateral side served as the control. After 28 days, both premolars were extracted. The teeth were scanned under microcomputed tomography, and the volumes of root resorption craters were calculated and compared. Premolars treated with micro-osteoperforation exhibited significantly greater average total amounts of root resorption than did the control teeth (0.576 vs 0.406 mm 3 ). The total average volumetric root loss of premolars treated with micro-osteoperforation was 42% greater than that of the control teeth. This 28-day trial showed that micro-osteoperforations resulted in greater orthodontic root resorption. However, these results should be verified in patients who are undergoing full-length orthodontic treatment. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
Alves, Flávio R F; Andrade-Junior, Carlos V; Marceliano-Alves, Marília F; Pérez, Alejandro R; Rôças, Isabela N; Versiani, Marco A; Sousa-Neto, Manoel D; Provenzano, José C; Siqueira, José F
2016-11-01
This study evaluated the disinfecting ability of chemomechanical preparation with rotary nickel-titanium instruments, followed by 2 distinct adjunctive procedures in the root canals of extracted mandibular molars by means of a correlative analytical approach. Twenty-two extracted mandibular molars were selected and anatomically matched between groups on the basis of micro-computed tomographic analysis. In the first phase of the experiment, root canals were contaminated with Enterococcus faecalis and subjected to chemomechanical preparation with BT RaCe instruments and 2.5% NaOCl irrigation. Then either XP-Endo Finisher instrument or passive ultrasonic irrigation was used to supplement disinfection. Micro-computed tomography was used to show whether the percentage of unprepared areas correlated to bacterial counts. In the second phase, the same teeth were contaminated once again, and the adjunctive procedures were used. Samples from the isthmus area of mesial roots and the apical 5-mm fragment of distal roots were obtained by cryopulverization. Samples taken before and after treatment steps in both phases were evaluated by quantitative polymerase chain reaction and statistically analyzed. In phase 1, preparation in both groups resulted in substantial decrease of bacterial counts (P < .001). The adjunctive approaches led to a further small bacterial reduction, which was significant for XP-Endo Finisher (P < .05). No significant differences were observed between groups for persisting bacterial counts. Correlative analysis revealed no statistically significant relationship between bacterial reduction and the percentage of unprepared areas (P > .05). In phase 2, both methods had significant antibacterial effects in the main canal, but none of them could predictably disinfect the isthmus/recess areas. Both XP-Endo Finisher and passive ultrasonic irrigation exhibited antibacterial effectiveness, but only the former caused a significant reduction in the bacterial counts after chemomechanical preparation. None of them were effective in predictably disinfecting the isthmus/recess areas. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Analysis of micro computed tomography images; a look inside historic enamelled metal objects
NASA Astrophysics Data System (ADS)
van der Linden, Veerle; van de Casteele, Elke; Thomas, Mienke Simon; de Vos, Annemie; Janssen, Elsje; Janssens, Koen
2010-02-01
In this study the usefulness of micro-Computed Tomography (µ-CT) for the in-depth analysis of enamelled metal objects was tested. Usually investigations of enamelled metal artefacts are restricted to non-destructive surface analysis or analysis of cross sections after destructive sampling. Radiography, a commonly used technique in the field of cultural heritage studies, is limited to providing two-dimensional information about a three-dimensional object (Lang and Middleton, Radiography of Cultural Material, pp. 60-61, Elsevier-Butterworth-Heinemann, Amsterdam-Stoneham-London, 2005). Obtaining virtual slices and information about the internal structure of these objects was made possible by CT analysis. With this technique the underlying metal work was studied without removing the decorative enamel layer. Moreover visible defects such as cracks were measured in both width and depth and as of yet invisible defects and weaker areas are visualised. All these features are of great interest to restorers and conservators as they allow a view inside these objects without so much as touching them.
Hammad, Mohammad; Qualtrough, Alison; Silikas, Nick
2008-11-01
The aim of this study was to measure the remaining filling volume of different obturation materials from root-filled extracted teeth by using 2 removal techniques. Eighty single-rooted teeth were collected and decoronated, and the root canal was prepared by using the ProTaper nickel-titanium rotary files. The teeth were randomly allocated into 4 groups, and each group was obturated by using a different material. Group 1 was filled with gutta-percha and TubliSeal sealer, group 2 was filled with EndoRez points and EndoRez sealer, group 3 was filled with RealSeal points and RealSeal sealer, and Group 4 was filled with a gutta-percha point and GuttaFlow sealer. Teeth were scanned with a micro-computed tomography scan, and then root fillings were removed by using ProTaper retreatment files or hand K-files. Teeth were scanned again, and volume measurements were carried out with micro-computed tomography software. Statistical analysis showed significant differences between the 2 removal techniques for gutta-percha and for both techniques between gutta-percha and the other groups. The present study showed that all tested filling materials were not completely removed during retreatment by using hand or rotary files. Gutta-percha was more efficiently removed by using hand K-files.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vetter, L. de; Cnudde, V.; Masschaele, B.
This article explores the potential of a scanning electron microscope with an energy dispersive X-ray spectrometer in combination with a new non-destructive 3D visualization technique, X-ray micro-computed tomography, as detection methods for siloxanes/silanes mixtures applied as wood preservatives. In order to have a higher contrast, bromine functional silane was added to the mixture. Scots pine and beech samples were dipped or impregnated with the mixture and subsequently scanned. Both silicon and bromine were easily detectable with both techniques. Dipped siloxanes/silanes covered the cell walls partly in beech and the lumen partly or completely in Scots pine. Impregnated siloxanes/silanes could bemore » found in the cell walls of both wood species. From the results, it can be concluded that, under the circumstances as described in the article, impregnation with a siloxane is necessary to have cell wall penetration. The combination of scanning electron microscopy, energy dispersive X-ray spectroscopy and micro-computed tomography can offer important information concerning the localization of certain products inside wood. While the last of these can monitor changes in 3D, the other two techniques can provide detailed 2D information. Both techniques are complementary and provide important extra information.« less
Comparison of digital intraoral scanners by single-image capture system and full-color movie system.
Yamamoto, Meguru; Kataoka, Yu; Manabe, Atsufumi
2017-01-01
The use of dental computer-aided design/computer-aided manufacturing (CAD/CAM) restoration is rapidly increasing. This study was performed to evaluate the marginal and internal cement thickness and the adhesive gap of internal cavities comprising CAD/CAM materials using two digital impression acquisition methods and micro-computed tomography. Images obtained by a single-image acquisition system (Bluecam Ver. 4.0) and a full-color video acquisition system (Omnicam Ver. 4.2) were divided into the BL and OM groups, respectively. Silicone impressions were prepared from an ISO-standard metal mold, and CEREC Stone BC and New Fuji Rock IMP were used to create working models (n=20) in the BL and OM groups (n=10 per group), respectively. Individual inlays were designed in a conventional manner using designated software, and all restorations were prepared using CEREC inLab MC XL. These were assembled with the corresponding working models used for measurement, and the level of fit was examined by three-dimensional analysis based on micro-computed tomography. Significant differences in the marginal and internal cement thickness and adhesive gap spacing were found between the OM and BL groups. The full-color movie capture system appears to be a more optimal restoration system than the single-image capture system.
NASA Astrophysics Data System (ADS)
Kameswara Rao, P. V.; Rawal, Amit; Kumar, Vijay; Rajput, Krishn Gopal
2017-10-01
Absorptive glass mat (AGM) separators play a key role in enhancing the cycle life of the valve regulated lead acid (VRLA) batteries by maintaining the elastic characteristics under a defined level of compression force with the plates of the electrodes. Inevitably, there are inherent challenges to maintain the required level of compression characteristics of AGM separators during the charge and discharge of the battery. Herein, we report a three-dimensional (3D) analytical model for predicting the compression-recovery behavior of AGM separators by formulating a direct relationship with the constituent fiber and structural parameters. The analytical model of compression-recovery behavior of AGM separators has successfully included the fiber slippage criterion and internal friction losses. The presented work uses, for the first time, 3D data of fiber orientation from X-ray micro-computed tomography, for predicting the compression-recovery behavior of AGM separators. A comparison has been made between the theoretical and experimental results of compression-recovery behavior of AGM samples with defined fiber orientation characteristics. In general, the theory agreed reasonably well with the experimental results of AGM samples in both dry and wet states. Through theoretical modeling, fiber volume fraction was established as one of the key structural parameters that modulates the compression hysteresis of an AGM separator.
Zu, Qianhui; Fang, Huan; Zhou, Hu; Zhang, Jianwei; Peng, Xinhua; Lin, Xiangui; Feng, Youzhi
2016-01-04
X-ray micro-computed tomography (micro-CT) technology, as used in the in situ and nondestructive analysis of soil physical structure, provides the opportunity of associating soil physical and biological assays. Due to the high heterogeneity of the soil matrix, X-ray micro-CT scanning and soil microbial assays should be conducted on the same soil sample. This raises the question whether X-ray micro-CT influences microbial function and diversity of the sample soil to be analyzed. To address this question, we used plate counting, microcalorimetry and pyrosequencing approaches to evaluate the effect of X-ray--at doses typically used in micro-CT--on soil microorganisms in a typical soil of North China Plain, Fluvo-aquic soil and in a typical soil of subtropical China, Ultisol soil, respectively. In both soils radiation decreased the number of viable soil bacteria and disturbed their thermogenic profiles. At DNA level, pyrosequencing revealed that alpha diversities of two soils biota were influenced in opposite ways, while beta diversity was not affected although the relative abundances of some guilds were changed. These findings indicate that the metabolically active aspects of soil biota are not compatible with X-ray micro-CT; while the beta molecular diversity based on pyrosequencing could be compatible.
NASA Astrophysics Data System (ADS)
Zhu, Bangshang; Yuan, Falei; Yuan, Xiaoya; Bo, Yang; Wang, Yongting; Yang, Guo-Yuan; Drummen, Gregor P. C.; Zhu, Xinyuan
2014-02-01
Micro-computed tomography (micro-CT) is a powerful tool for visualizing the vascular systems of tissues, organs, or entire small animals. Vascular contrast agents play a vital role in micro-CT imaging in order to obtain clear and high-quality images. In this study, a new kind of nanostructured barium phosphate was fabricated and used as a contrast agent for ex vivo micro-CT imaging of blood vessels in the mouse brain. Nanostructured barium phosphate was synthesized through a simple wet precipitation method using Ba(NO3)2, and (NH4)2HPO4 as starting materials. The physiochemical properties of barium phosphate were characterized by scanning electron microscopy, transmission electron microscopy, X-ray diffraction, Fourier transform infrared spectroscopy, and thermal analysis. Furthermore, the impact of the produced nanostructures on cell viability was evaluated via the MTT assay, which generally showed low to moderate cytotoxicity. Finally, the animal test images demonstrated that the use of nanostructured barium phosphate as a contrast agent in Micro-CT imaging produced sharp images with excellent contrast. Both major vessels and the microvasculature were clearly observable in the imaged mouse brain. Overall, the results indicate that nanostructured barium phosphate is a potential and useful vascular contrast agent for micro-CT imaging.
Hedayat, Assem; Nagy, Nicole; Packota, Garnet; Monteith, Judy; Allen, Darcy; Wysokinski, Tomasz; Zhu, Ning
2016-05-01
Dental burs are used extensively in dentistry to mechanically prepare tooth structures for restorations (fillings), yet little has been reported on the bur debris left behind in the teeth, and whether it poses potential health risks to patients. Here it is aimed to image dental bur debris under dental fillings, and allude to the potential health hazards that can be caused by this debris when left in direct contact with the biological surroundings, specifically when the debris is made of a non-biocompatible material. Non-destructive micro-computed tomography using the BioMedical Imaging & Therapy facility 05ID-2 beamline at the Canadian Light Source was pursued at 50 keV and at a pixel size of 4 µm to image dental bur fragments under a composite resin dental filling. The bur's cutting edges that produced the fragment were also chemically analyzed. The technique revealed dental bur fragments of different sizes in different locations on the floor of the prepared surface of the teeth and under the filling, which places them in direct contact with the dentinal tubules and the dentinal fluid circulating within them. Dispersive X-ray spectroscopy elemental analysis of the dental bur edges revealed that the fragments are made of tungsten carbide-cobalt, which is bio-incompatible.
Differences in the developmental origins of the periosteum may influence bone healing.
Ichikawa, Y; Watahiki, J; Nampo, T; Nose, K; Yamamoto, G; Irie, T; Mishima, K; Maki, K
2015-08-01
The jaw bone, unlike most other bones, is derived from neural crest stem cells, so we hypothesized that it may have different characteristics to bones from other parts of the body, especially in the nature of its periosteum. The periosteum exhibits osteogenic potential and has received considerable attention as a grafting material for the repair of bone and joint defects. Gene expression profiles of jaw bone and periosteum were evaluated by DNA microarray and real-time polymerase chain reaction. Furthermore, we perforated an area 2 mm in diameter on mouse frontal and parietal bones. Bone regeneration of these calvarial defects was evaluated using microcomputed tomography and histological analysis. The DNA microarray data revealed close homology between the gene expression profiles within the ilium and femur. The gene expression of Wnt-1, SOX10, nestin, and musashi-1 were significantly higher in the jaw bone than in other locations. Microcomputed tomography and histological analysis revealed that the jaw bone had superior bone regenerative abilities than other bones. Jaw bone periosteum exhibits a unique gene expression profile that is associated with neural crest cells and has a positive influence on bone regeneration when used as a graft material to repair bone defects. A full investigation of the biological and mechanical properties of jaw bone as an alternative graft material for jaw reconstructive surgery is recommended. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Pallua, Johannes D; Kuhn, Volker; Pallua, Anton F; Pfaller, Kristian; Pallua, Anton K; Recheis, Wolfgang; Pöder, Reinhold
2015-01-01
The potential of 3-D nondestructive imaging techniques such as micro-computed tomography (micro-CT) was evaluated to study morphological patterns of the potential medicinal fungus Hericium coralloides (Basidiomycota). Micro-CT results were correlated with histological information gained from scanning electron microscopy (SEM) and light microscopy (LM). It is demonstrated that the combination of these imaging methods results in a more distinct picture of the morphology of the edible and potentially medicinal Hericium coralloides basidiomata. In addition we have created 3-D reconstructions and visualizations based on micro-CT imagery from a randomly selected part of the upper region of a fresh H. coralloides basidioma: Analyses for the first time allowed an approximation of the evolutionary effectiveness of this bizarrely formed basidioma type in terms of the investment of tissue biomass and its reproductive output (production of basidiospores). © 2015 by The Mycological Society of America.
Affatato, Saverio; Zanini, Filippo; Carmignato, Simone
2017-01-01
Wear is currently quantified as mass loss of the bearing materials measured using gravimetric methods. However, this method does not provide other information, such as volumetric loss or surface deviation. In this work, we validated a technique to quantify polyethylene wear in three different batches of ultrahigh-molecular-polyethylene acetabular cups used for hip implants using nondestructive microcomputed tomography. Three different configurations of polyethylene acetabular cups, previously tested under the ISO 14242 parameters, were tested on a hip simulator for an additional 2 million cycles using a modified ISO 14242 load waveform. In this context, a new approach was proposed in order to simulate, on a hip joint simulator, high-demand activities. In addition, the effects of these activities were analyzed in terms of wear and deformations of those polyethylenes by means of gravimetric method and micro X-ray computed tomography. In particular, while the gravimetric method was used for weight loss assessment, microcomputed tomography allowed for acquisition of additional quantitative information about the evolution of local wear and deformation through three-dimensional surface deviation maps for the entire cups’ surface. Experimental results showed that the wear and deformation behavior of these materials change according to different mechanical simulations. PMID:28772616
Gianakos, Arianna L; Yasui, Youichi; Fraser, Ethan J; Ross, Keir A; Prado, Marcelo P; Fortier, Lisa A; Kennedy, John G
2016-10-01
To evaluate morphological alterations, microarchitectural disturbances, and the extent of bone marrow access to the subchondral bone marrow compartment using micro-computed tomography analysis in different bone marrow stimulation (BMS) techniques. Nine zones in a 3 × 3 grid pattern were assigned to 5 cadaveric talar dome articular surfaces. A 1.00-mm microfracture awl (s.MFX), a 2.00-mm standard microfracture awl (l.MFX), or a 1.25-mm Kirschner wire (K-wire) drill hole was used to penetrate the subchondral bone in each grid zone. Subchondral bone holes and adjacent tissue areas were assessed by micro-computed tomography to analyze adjacent bone area destruction and communicating channels to the bone marrow. Grades 1 to 3 were assigned, where 1 = minimal compression/sclerosis; 2 = moderate compression/sclerosis; 3 = severe compression/sclerosis. Bone volume/total tissue volume, bone surface area/bone volume, trabecular thickness, and trabecular number were calculated in the region of interest. Visual assessment revealed that the s.MFX had significantly more grade 1 holes (P < .001) and that the l.MFX had significantly more poor/grade 3 holes (P = .002). Bone marrow channel assessment showed a statistically significant increase in the number of channels in the s.MFX when compared with both K-wire and l.MFX holes (P < .001). Bone volume fraction for the s.MFX was significantly less than that of the l.MFX (P = .029). BMS techniques using instruments with larger diameters resulted in increased trabecular compaction and sclerosis in areas adjacent to the defect. K-wire and l.MFX techniques resulted in less open communicating bone marrow channels, denoting a reduction in bone marrow access. The results of this study indicate that BMS using larger diameter devices results in greater microarchitecture disturbances. The current study suggests that the choice of a BMS technique should be carefully considered as the results indicate that smaller diameter hole sizes may diminish the amount of microarchitectural disturbances in the subchondral bone. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Quantitative 3D analysis of the canal network in cortical bone by micro-computed tomography.
Cooper, D M L; Turinsky, A L; Sensen, C W; Hallgrímsson, B
2003-09-01
Cortical bone is perforated by an interconnected network of porous canals that facilitate the distribution of neurovascular structures throughout the cortex. This network is an integral component of cortical microstructure and, therefore, undergoes continual change throughout life as the cortex is remodeled. To date, the investigation of cortical microstructure, including the canal network, has largely been limited to the two-dimensional (2D) realm due to methodological hurdles. Thanks to continuing improvements in scan resolution, micro-computed tomography (muCT) is the first nondestructive imaging technology capable of resolving cortical canals. Like its application to trabecular bone, muCT provides an efficient means of quantifying aspects of 3D architecture of the canal network. Our aim here is to introduce the use of muCT for this application by providing examples, discussing some of the parameters that can be acquired, and relating these to research applications. Although several parameters developed for the analysis of trabecular microstructure are suitable for the analysis of cortical porosity, the algorithm used to estimate connectivity is not. We adapt existing algorithms based on skeletonization for this task. We believe that 3D analysis of the dimensions and architecture of the canal network will provide novel information relevant to many aspects of bone biology. For example, parameters related to the size, spacing, and volume of the canals may be particularly useful for investigation of the mechanical properties of bone. Alternatively, parameters describing the 3D architecture of the canal network, such as connectivity between the canals, may provide a means of evaluating cumulative remodeling related change. Copyright 2003 Wiley-Liss, Inc.
Ramakrishaniah, Ravikumar; Al Kheraif, Abdulaziz A; Elsharawy, Mohamed A; Alsaleh, Ayman K; Ismail Mohamed, Karem M; Rehman, Ihtesham Ur
2015-05-01
The purpose of this study was to investigate and compare the load distribution and displacement of cantilever prostheses with and without glass abutment by three dimensional finite element analysis. Micro-computed tomography was used to study the relationship between the glass abutment and the ridge. The external surface of the maxilla was scanned, and a simplified finite element model was constructed. The ZX-27 glass abutment and the maxillary first and second premolars were created and modified. The solid model of the three-unit cantilever fixed partial denture was scanned, and the fitting surface was modified with reference to the created abutments using the 3D CAD system. The finite element analysis was completed in ANSYS. The fit and total gap volume between the glass abutment and dental model were determined by Skyscan 1173 high-energy spiral micro-CT scan. The results of the finite element analysis in this study showed that the cantilever prosthesis supported by the glass abutment demonstrated significantly less stress on the terminal abutment and overall deformation of the prosthesis under vertical and oblique load. Micro-computed tomography determined a gap volume of 6.74162 mm(3). By contacting the mucosa, glass abutments transfer some amount of masticatory load to the residual alveolar ridge, thereby preventing damage to the periodontal microstructures of the terminal abutment. The passive contact of the glass abutment with the mucosa not only preserves the health of the mucosa covering the ridge but also permits easy cleaning. It is possible to increase the success rate of cantilever FPDs by supporting the cantilevered pontic with glass abutments. Copyright © 2015 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Ahmetoglu, Fuat; Keles, Ali; Simsek, Neslihan; Ocak, M Sinan; Yologlu, Saim
2015-01-01
This study was aimed to use micro-computed tomography (μ-CT) to evaluate the canal shaping properties of three nickel-titanium instruments, Self-Adjusting File (SAF), Reciproc, and Revo-S rotary file, in maxillary first molars. Thirty maxillary molars were scanned preoperatively by using micro-computed tomography (μ-CT) scans at 13,68 μm resolution. The teeth were randomly assigned to three groups (n = 10). The root canals were shaped with SAF, Reciproc, and Revo-S, respectively. The shaped root canals were rescanned. Changes in canal volumes and surface areas were compared with preoperative values. The data were analyzed using Kruskal-Wallis and Conover's post hoc tests, with p < .05 denoting a statistically significant difference. Preoperatively canal volumes and surface area were statistically similar among the three groups (p > .05). There were statistically significant differences in all measures comparing preoperative and postoperative canal models (p = 0.0001). These differences occurred after instrumentation among the three experimental groups showed no statistically significant difference for volume (p > .05). Surface area showed the similar activity in buccal canals in each of the three techniques whereas no statistically significant difference was detected among surface area, the SAF, and the Revo-S in the palatal (P) canal. Each of three shaping system showed the similar volume activity in all canals, but SAF and Revo-S provided more effectively root planning in comparison with Reciproc in P canal. © Wiley Periodicals, Inc.
Rebaudi, Alberto; Trisi, Paolo; Pagni, Giorgio; Wang, Hom-Lay
The purpose of this study was to compare microcomputed tomography (microCT) and histologic analysis outcomes of a periodontal regeneration of a human defect treated with a polylactic- and polyglycolic-acid copolymer. At 11 months following the grafting procedure, the root with the surrounding periodontal tissues was removed and analyzed using microCT and histologic techniques. The results suggest that microCT three-dimensional analysis may be used in synergy with two-dimensional histologic sections to provide additional information for studying the regeneration outcomes normally reported by histologic biopsies in humans. Additional data is needed to validate these findings.
The Effect of Experimental Variables on Industrial X-Ray Micro-Computed Sensitivity
NASA Technical Reports Server (NTRS)
Roth, Don J.; Rauser, Richard W.
2014-01-01
A study was performed on the effect of experimental variables on radiographic sensitivity (image quality) in x-ray micro-computed tomography images for a high density thin wall metallic cylinder containing micro-EDM holes. Image quality was evaluated in terms of signal-to-noise ratio, flaw detectability, and feature sharpness. The variables included: day-to-day reproducibility, current, integration time, voltage, filtering, number of frame averages, number of projection views, beam width, effective object radius, binning, orientation of sample, acquisition angle range (180deg to 360deg), and directional versus transmission tube.
The microstructure of capsule containing self-healing materials: A micro-computed tomography study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Van Stappen, Jeroen, E-mail: Jeroen.Vanstappen@uge
Autonomic self-healing materials are materials with built-in (micro-) capsules or vessels, which upon fracturing release healing agents in order to recover the material's physical and mechanical properties. In order to better understand and engineer these materials, a thorough characterization of the material's microstructural behavior is essential and often overlooked. In this context, micro-computed tomography (μCT) can be used to investigate the three dimensional distribution and (de)bonding of (micro-) capsules in their native state in a polymer system with self-healing properties. Furthermore, in-situ μCT experiments in a self-healing polymer and a self-healing concrete system can elucidate the breakage and leakage behaviormore » of (micro-) capsules at the micrometer scale. While challenges related to image resolution and contrast complicate the characterization in specific cases, non-destructive 3D imaging with μCT is shown to contribute to the understanding of the link between the microstructure and the self-healing behavior of these complex materials. - Highlights: • μCT imaging allows for the analysis of microcapsule distribution patterns in self-healing materials. • μCT allows for qualitative and quantitative measurements of healing agent release from carriers in self-healing materials. • Experimental set-ups can be optimized by changing chemical compounds in the system to ensure maximum quality imaging.« less
Fracture healing using degradable magnesium fixation plates and screws.
Chaya, Amy; Yoshizawa, Sayuri; Verdelis, Kostas; Noorani, Sabrina; Costello, Bernard J; Sfeir, Charles
2015-02-01
Internal bone fixation devices made with permanent metals are associated with numerous long-term complications and may require removal. We hypothesized that fixation devices made with degradable magnesium alloys could provide an ideal combination of strength and degradation, facilitating fracture fixation and healing while eliminating the need for implant removal surgery. Fixation plates and screws were machined from 99.9% pure magnesium and compared with titanium devices in a rabbit ulnar fracture model. Magnesium device degradation and the effect on fracture healing and bone formation were assessed after 4 weeks. Fracture healing with magnesium device fixation was compared with that of titanium devices using qualitative histologic analysis and quantitative histomorphometry. Micro-computed tomography showed device degradation after 4 weeks in vivo. In addition, 2-dimensional micro-computed tomography slices and histologic staining showed that magnesium degradation did not inhibit fracture healing or bone formation. Histomorphology showed no difference in bone-bridging fractures fixed with magnesium and titanium devices. Interestingly, abundant new bone was formed around magnesium devices, suggesting a connection between magnesium degradation and bone formation. Our results show potential for magnesium fixation devices in a loaded fracture environment. Furthermore, these results suggest that magnesium fixation devices may enhance fracture healing by encouraging localized new bone formation. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Lee, Jong-Ki; Ha, Byung-Hyun; Choi, Jeong-Ho; Heo, Seok-Mo; Perinpanayagam, Hiran
2006-10-01
In endodontic therapy, access and instrumentation are strongly affected by root canal curvature. However, the few studies that have actually measured curvature are mostly from two-dimensional radiographs. The purpose of this study was to measure the three-dimensional (3D) canal curvature in maxillary first molars using micro-computed tomography (microCT) and mathematical modeling. Extracted maxillary first molars (46) were scanned by microCT (502 image slices/tooth, 1024 X 1024 pixels, voxel size of 19.5 x 19.5 x 39.0 microm) and their canals reconstructed by 3D modeling software. The intersection of major and minor axes in the canal space of each image slice were connected to create an imaginary central axis for each canal. The radius of curvature of the tangential circle was measured and inverted as a measure of curvature using custom-made mathematical modeling software. Root canal curvature was greatest in the apical third and least in the middle third for all canals. The greatest curvatures were in the mesiobuccal (MB) canal (0.76 +/- 0.48 mm(-1)) with abrupt curves, and the least curvatures were in the palatal (P) canal (0.38 +/- 0.34 mm(-1)) with a gradual curve. This study has measured the 3D curvature of root canals in maxillary first molars and reinforced the value of microCT with mathematical modeling.
Root canal morphology of primary molars: a micro-computed tomography study.
Fumes, A C; Sousa-Neto, M D; Leoni, G B; Versiani, M A; da Silva, L A B; da Silva, R A B; Consolaro, A
2014-10-01
This was to investigate the root canal morphology of primary molar teeth using micro-computed tomography. Primary maxillary (n = 20) and mandibular (n = 20) molars were scanned at a resolution of 16.7 μm and analysed regarding the number, location, volume, area, structured model index (SMI), area, roundness, diameters, and length of canals, as well as the thickness of dentine in the apical third. Data were statistically compared by using paired-sample t test, independent sample t test, and one-way analysis of variance with significance level set as 5%. Overall, no statistical differences were found between the canals with respect to length, SMI, dentine thickness, area, roundness, and diameter (p > 0.05). A double canal system was observed in the mesial and mesio-buccal roots of the mandibular and maxillary molars, respectively. The thickness in the internal aspect of the roots was lower than in the external aspect. Cross-sectional evaluation of the roots in the apical third showed flat-shaped canals in the mandibular molars and ribbon- and oval-shaped canals in the maxillary molars. External and internal anatomy of the primary first molars closely resemble the primary second molars. The reported data may help clinicians to obtain a thorough understanding of the morphological variations of root canals in primary molars to overcome problems related to shaping and cleaning procedures, allowing appropriate management strategies for root canal treatment.
Ozgul, Betul Memis; Orhan, Kaan; Oz, Firdevs Tulga
2015-09-01
We investigated inhibition of lesion progression in artificial enamel lesions. Lesions were created on primary and permanent anterior teeth (n = 10 each) and were divided randomly into two groups with two windows: Group 1 (window A: resin infiltration; window B: negative control) and Group 2 (window A: resin infiltration + fluoride varnish; window B: fluoride varnish). After pH cycling, micro-computed tomography was used to analyze progression of lesion depth and changes in mineral density. Resin infiltration and resin infiltration + fluoride varnish significantly inhibited progression of lesion depth in primary teeth (P < 0.05). Inhibition of lesion depth progression in permanent teeth was significantly greater after treatment with resin infiltration + fluoride varnish than in the negative control (P < 0.05). Change in mineral density was smaller in the resin infiltration and resin infiltration + fluoride varnish groups; however, the difference was not significant for either group (P > 0.05). Resin infiltration is a promising method of inhibiting progression of caries lesions.
Grover, Steven P; Saha, Prakash; Jenkins, Julia; Mukkavilli, Arun; Lyons, Oliver T; Patel, Ashish S; Sunassee, Kavitha; Modarai, Bijan; Smith, Alberto
2015-12-01
The assessment of thrombus size following treatments directed at preventing thrombosis or enhancing its resolution has generally relied on physical or histological methods. This cross-sectional design imposes the need for increased numbers of animals for experiments. Micro-computed tomography (microCT) has been used to detect the presence of venous thrombus in experimental models but has yet to be used in a quantitative manner. In this study, we investigate the use of contrast-enhanced microCT for the longitudinal assessment of experimental venous thrombus resolution. Thrombi induced by stenosis of the inferior vena cava in mice were imaged by contrast-enhanced microCT at 1, 7 and 14 days post-induction (n=18). Thrombus volumes were determined longitudinally by segmentation and 3D volume reconstruction of microCT scans and by standard end-point histological analysis at day 14. An additional group of thrombi were analysed solely by histology at 1, 7 and 14 days post-induction (n=15). IVC resident thrombus was readily detectable by contrast-enhanced microCT. MicroCT-derived measurements of thrombus volume correlated well with time-matched histological analyses (ICC=0.75, P<0.01). Thrombus volumes measured by microCT were significantly greater than those derived from histological analysis (P<0.001). Intra- and inter-observer analyses were highly correlated (ICC=0.99 and 0.91 respectively, P<0.0001). Further histological analysis revealed noticeable levels of contrast agent extravasation into the thrombus that was associated with the presence of neovascular channels, macrophages and intracellular iron deposits. Contrast-enhanced microCT represents a reliable and reproducible method for the longitudinal assessment of venous thrombus resolution providing powerful paired data. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
Comparison of Bone Grafts From Various Donor Sites in Human Bone Specimens.
Kamal, Mohammad; Gremse, Felix; Rosenhain, Stefanie; Bartella, Alexander K; Hölzle, Frank; Kessler, Peter; Lethaus, Bernd
2018-05-14
The objective of the current study was to compare the three-dimensional (3D) morphometric microstructure in human cadaveric bone specimens taken from various commonly utilized donor sites for autogenous bone grafting. Autogenous bone grafts can be harvested from various anatomic sites and express heterogeneous bone quality with a specific 3D microstructure for each site. The long-term structural integrity and susceptibility to resorption of the graft depend on the selected donor bone. Micro-computed tomography generates high-resolution datasets of bone structures and calcifications making this modality versatile for microarchitecture analysis and quantification of the bone. Six bone specimens, 10 mm in length, where anatomically possible, were obtained from various anatomical sites from 10 human dentate cadavers (4 men, 6 women, mean age 69.5 years). Specimens were scanned using a micro-computed tomography device and volumetrically reconstructed. A virtual cylindrical inclusion was reconstructed to analyze the bone mineral density and structural morphometric analysis using bone indices: relative bone volume, surface density, trabecular thicknesses, and trabecular separation. Calvarial bone specimens showed the highest mineral density, followed by the chin, then mandibular ramus then the tibia, whereas iliac crest and maxillary tuberosity had lower bone mineral densities. The pairwise comparison revealed statistically significant differences in the bone mineral density and relative bone volume index in the calvaria, mandibular ramus, mandibular symphysis groups when compared with those in the iliac crest and maxillary tuberosity, suggesting higher bone quality in the former groups than in the latter; tibial specimens expressed variable results.
Park, Hye-Shin; Lee, Yong Sun; Choi, Eun-Young; Choi, Jeom-Il; Choi, In Soon; Kim, Sung-Jo
2017-06-01
Azithromycin, a macrolide antibiotic, has anti-inflammatory and immunomodulatory activities apart from its antibacterial properties. In this study, we examined the efficacy of subantibiotic dose of azithromycin on ligature-induced periodontitis in rats using micro-computed tomography (micro-CT) imaging and bone parameter analysis. Male Sprague-Dawley rats were allocated to the following four groups: non-ligation (NL) group; ligation-only (L) group; ligation-plus-subantibiotic dose azithromycin (SA) group; and 4) ligation-plus-antibiotic dose azithromycin (AA) group. The rats from Groups L, SA and AA were subjected to periodontitis by placing a ligature around lower right first molar. Immediately after ligation, the rats in SA and AA groups received daily intraperitoneal injections of azithromycin at a dosage of 3.5 or 10mg/kg body weight, respectively. The ligatures were maintained for 2weeks at which time the rats had their mandibles hemisected for micro-CT analysis. Subantibiotic dose of azithromycin strongly suppressed reductions in alveolar bone height and bone volume fraction caused by experimental periodontitis. When subantibiotic dosage of azithromycin was administered to rats, ligature-induced alterations in microarchitectural parameters of trabecular bone were significantly reversed. Rats treated with subantibiotic dose of azithromycin presented no significant difference compared to rats with antibiotic dosage in all parameters. While further studies are necessary, subantibiotic dose of azithromycin could be utilized as a host modulator for the treatment of periodontitis. Copyright © 2017 Elsevier B.V. All rights reserved.
Zhang, Liu; Wu, Li; Wang, Caifen; Zhang, Guoqing; Yu, Lin; Li, Haiyan; Maharjan, Abi; Tang, Yan; He, Dunwei; York, Peter; Sun, Huimin; Yin, Xianzhen; Zhang, Jiwen; Sun, Lixin
2018-03-06
One unusual and challenging scientific field that has received only cursory attention to date is the three-dimensional (3D) microstructure and spatial distribution of drug(s) and formulation materials in solid dosage forms. This study aims to provide deeper insight into the relationships between the microstructure of multiple-unit pellet system (MUPS) tablets and the spatial distribution of the active pharmaceutical ingredient (API) and excipients to facilitate the design of quantitative models for drug delivery systems. Synchrotron radiation X-ray microcomputed tomography (SR-μCT) was established as a 3D structure elucidation technique, which, in conjunction with liquid chromatography coupled to mass spectrometry (LC-MS) or liquid chromatography with evaporative light-scattering detector (LC-ELSD) enables chemical analysis of tablets. On the basis of the specific interior construction of theophylline MUPS tablets, the spatial distribution of materials was acquired by quantifying microregion samples that had been validated by SR-μCT for their locations in the MUPS tablets. The 3D structure of the MUPS tablets was catalogued as three structural domains: a matrix layer (ML), a protective cushion layer (PCL), and pellets (PL). Compared with the components in the ML, components in the PL had a larger proportion of theophylline, sucrose, and diethyl phthalate and a smaller proportion of lactose and sodium lauryl sulfate, whereas glyceryl monostearate was found to account for a large portion of the PCL. Microstructural characterization-guided zonal chemical determination represents a new approach for quality assessment and the development of drug delivery systems with in-depth insight into their constituent layers on a new scale.
Mural, Prasanna Kumar S; Jain, Shubham; Kumar, Sachin; Madras, Giridhar; Bose, Suryasarathi
2016-04-21
3D porous membranes were developed by etching one of the phases (here PEO, polyethylene oxide) from melt-mixed PE/PEO binary blends. Herein, we have systematically discussed the development of these membranes using X-ray micro-computed tomography. The 3D tomograms of the extruded strands and hot-pressed samples revealed a clear picture as to how the morphology develops and coarsens over a function of time during post-processing operations like compression molding. The coarsening of PE/PEO blends was traced using X-ray micro-computed tomography and scanning electron microscopy (SEM) of annealed blends at different times. It is now understood from X-ray micro-computed tomography that by the addition of a compatibilizer (here lightly maleated PE), a stable morphology can be visualized in 3D. In order to anchor biocidal graphene oxide sheets onto these 3D porous membranes, the PE membranes were chemically modified with acid/ethylene diamine treatment to anchor the GO sheets which were further confirmed by Fourier transform infrared spectroscopy (FTIR), X-ray photoelectron spectroscopy (XPS) and surface Raman mapping. The transport properties through the membrane clearly reveal unimpeded permeation of water which suggests that anchoring GO on to the membranes does not clog the pores. Antibacterial studies through the direct contact of bacteria with GO anchored PE membranes resulted in 99% of bacterial inactivation. The possible bacterial inactivation through physical disruption of the bacterial cell wall and/or reactive oxygen species (ROS) is discussed herein. Thus this study opens new avenues in designing polyolefin based antibacterial 3D porous membranes for water purification.
Wolf, Thomas Gerhard; Paqué, Frank; Zeller, Maximilian; Willershausen, Brita; Briseño-Marroquín, Benjamín
2016-04-01
The aim of this study was to investigate the root canal system morphology of the mandibular first molar by means of micro-computed tomography. The root canal configuration, foramina, and accessory canals frequency of 118 mandibular first molars were investigated by means of micro-computed tomography and 3-dimensional software imaging. A 4-digit system describes the root canal configuration from the coronal to apical thirds and the main foramina number. The most frequent root canal configurations in mesial root were 2-2-2/2 (31.4%), 2-2-1/1 (15.3%), and 2-2-2/3 (11.9%); another 24 different root canal configurations were observed in this root. A 1-1-1/1 (58.5%), 1-1-1/2 (10.2%), and 16 other root canal configurations were observed in the distal root. The mesiobuccal root canal showed 1-4 foramina in 24.6%, and the mesiolingual showed 1-3 foramina in 28.0%. One connecting canal between the mesial root canals was observed in 30.5% and 2 in 3.4%. The distolingual root canal showed 1-4 foramina in 23.7%, whereas a foramen in the distobuccal root canal was rarely detected (3.4%). The mesiobuccal, mesiolingual, and distolingual root canals showed at least 1 accessory canal (14.3, 10.2, and 4.2%, respectively), but the distobuccal had none. The root canal configuration of mandibular first molars varies strongly. According to our expectations, both the mesial and distal roots showed a high number of morphologic diversifications. The root canal system of the mesial root showed more root canal configuration variations, connecting and accessory canals than the distal root. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
A brief review of chronic obstructive pulmonary disease.
Hogg, James C
2012-01-01
A recent study, based on a combination of multidetector computed tomography scanning of an intact specimen with microcomputed tomography and histological analysis of lung tissue samples, reported that the number of terminal bronchioles were reduced from approximately 44,500/lung pair in control (donor) lungs to approximately 4800/lung pair in lungs donated by individuals with very severe (Global initiative for chronic Obstructive Lung Disease stage 4) chronic obstructive pulmonary disease (COPD) treated by lung transplantation. The present short review discusses the hypothesis that a rapid rate of terminal bronchiolar destruction causes the rapid decline in lung function leading to advanced COPD. With respect to why the terminal bronchioles are targeted for destruction, the postulated mechanisms of this destruction and the possibility that new treatments are able to either prevent or reverse the underlying cause of airway obstruction in COPD are addressed.
Advances in imaging: impact on studying craniofacial bone structure.
Majumdar, S
2003-01-01
Methods for measuring the structure of craniofacial bones are discussed in this paper. In addition to the three-dimensional macro-structure of the craniofacial skeleton, there is considerable interest in imaging the bone at a microscopic resolution in order to depict the micro-architecture of the trabecular bone itself. In addition to the density of the bone, the microarchitecture reflects bone quality. An understanding of bone quality and density changes has implications for a number of craniofacial pathologies, as well as for implant design and understanding the biomechanical function and loading of the jaw. Trabecular bone micro-architecture has been recently imaged using imaging methods such as micro-computed tomography, magnetic resonance imaging, and the images have been used in finite element models to assess bone mechanical properties. In this paper, some of the recent advances in micro-computed tomography and magnetic resonance imaging are reviewed, and their potential for imaging the trabecular bone in mandibular bones is presented. Examples of in vitro and in vivo images are presented.
Micro-Computed Tomography Evaluation of Human Fat Grafts in Nude Mice
Chung, Michael T.; Hyun, Jeong S.; Lo, David D.; Montoro, Daniel T.; Hasegawa, Masakazu; Levi, Benjamin; Januszyk, Michael; Longaker, Michael T.
2013-01-01
Background Although autologous fat grafting has revolutionized the field of soft tissue reconstruction and augmentation, long-term maintenance of fat grafts is unpredictable. Recent studies have reported survival rates of fat grafts to vary anywhere between 10% and 80% over time. The present study evaluated the long-term viability of human fat grafts in a murine model using a novel imaging technique allowing for in vivo volumetric analysis. Methods Human fat grafts were prepared from lipoaspirate samples using the Coleman technique. Fat was injected subcutaneously into the scalp of 10 adult Crl:NU-Foxn1nu CD-1 male mice. Micro-computed tomography (CT) was performed immediately following injection and then weekly thereafter. Fat volume was rendered by reconstructing a three-dimensional (3D) surface through cubic-spline interpolation. Specimens were also harvested at various time points and sections were prepared and stained with hematoxylin and eosin (H&E), for macrophages using CD68 and for the cannabinoid receptor 1 (CB1). Finally, samples were explanted at 8- and 12-week time points to validate calculated micro-CT volumes. Results Weekly CT scanning demonstrated progressive volume loss over the time course. However, volumetric analysis at the 8- and 12-week time points stabilized, showing an average of 62.2% and 60.9% survival, respectively. Gross analysis showed the fat graft to be healthy and vascularized. H&E analysis and staining for CD68 showed minimal inflammatory reaction with viable adipocytes. Immunohistochemical staining with anti-human CB1 antibodies confirmed human origin of the adipocytes. Conclusions Studies assessing the fate of autologous fat grafts in animals have focused on nonimaging modalities, including histological and biochemical analyses, which require euthanasia of the animals. In this study, we have demonstrated the ability to employ micro-CT for 3D reconstruction and volumetric analysis of human fat grafts in a mouse model. Importantly, this model provides a platform for subsequent study of fat manipulation and soft tissue engineering. PMID:22916732
Trend Analysis Using Microcomputers.
ERIC Educational Resources Information Center
Berger, Carl F.
A trend analysis statistical package and additional programs for the Apple microcomputer are presented. They illustrate strategies of data analysis suitable to the graphics and processing capabilities of the microcomputer. The programs analyze data sets using examples of: (1) analysis of variance with multiple linear regression; (2) exponential…
NASA Astrophysics Data System (ADS)
Sinescu, Cosmin; Negrutiu, Meda Lavinia; Ionita, Ciprian; Topala, Florin; Petrescu, Emanuela; Rominu, Roxana; Pop, Daniela Maria; Marsavina, Liviu; Negru, Radu; Bradu, Adrian; Rominu, Mihai; Podoleanu, Adrian Gh.
2010-12-01
Imagistic investigation of the metal-ceramic crowns and fixed partial prostheses represent a very important issue in nowadays dentistry. At this time, in dental office, it is difficult or even impossible to evaluate a metal ceramic crown or bridge before setting it in the oral cavity. The possibilities of ceramic fractures are due to small fracture lines or material defects inside the esthetic layers. Material and methods: In this study 25 metal ceramic crowns and fixed partial prostheses were investigated by radiographic method (Rx), micro computer tomography (MicroCT) and optical coherence tomography (OCT) working in Time Domain, at 1300 nm. The OCT system contains two interferometers and one scanner. For each incident analysis a stuck made of 100 slices was obtain. These slices were used in order to obtain a 3D model of the ceramic interface. Results: RX and MicroCT are very powerful instruments that provide a good characterization of the dental construct. It is important to observe the reflections due to the metal infrastructure that could affect the evaluation of the metal ceramic crowns and bridges. The OCT investigations could complete the imagistic evaluation of the dental construct by offering important information when it is need it.
NASA Astrophysics Data System (ADS)
Wu, Ping; Liu, Kai; Zhang, Qian; Xue, Zhenwen; Li, Yongbao; Ning, Nannan; Yang, Xin; Li, Xingde; Tian, Jie
2012-12-01
Liver cancer is one of the most common malignant tumors worldwide. In order to enable the noninvasive detection of small liver tumors in mice, we present a parallel iterative shrinkage (PIS) algorithm for dual-modality tomography. It takes advantage of microcomputed tomography and multiview bioluminescence imaging, providing anatomical structure and bioluminescence intensity information to reconstruct the size and location of tumors. By incorporating prior knowledge of signal sparsity, we associate some mathematical strategies including specific smooth convex approximation, an iterative shrinkage operator, and affine subspace with the PIS method, which guarantees the accuracy, efficiency, and reliability for three-dimensional reconstruction. Then an in vivo experiment on the bead-implanted mouse has been performed to validate the feasibility of this method. The findings indicate that a tiny lesion less than 3 mm in diameter can be localized with a position bias no more than 1 mm the computational efficiency is one to three orders of magnitude faster than the existing algorithms; this approach is robust to the different regularization parameters and the lp norms. Finally, we have applied this algorithm to another in vivo experiment on an HCCLM3 orthotopic xenograft mouse model, which suggests the PIS method holds the promise for practical applications of whole-body cancer detection.
Lawler, D F; Rubin, D A; Evans, R H; Hildebolt, C F; Smith, K E; Widga, C; Martin, T J; Siegel, M; Sackman, J E; Smith, G K; Patel, T K
2013-12-01
A proximal humeral articular surface from an ancient domestic dog deliberate burial was examined during survey of small mammal bones from a prehistoric early Late Woodland archeological site. An unusual lesion on the caudolateral articular surface prompted micro-computed tomography to define detailed structure. Results indicate cortical or immature woven bone arising subchondrally, replacing normal trabeculae, extending through a breach in the cortical surface, and having sharp transition with surrounding normal bone. Organized bone within the lesion indicates that the dog lived for months-to-years following insult. Differential diagnoses initially included: sharp penetrating trauma; intrinsic or extrinsic blunt fracturing force; osteochondrosis or complication of an osteochondral lesion; unusual osteoarthritis; and neoplasia. Computed tomography ruled out normal or unusual osteoarthritis, and neoplasia. The nature and small size of the lesion, relatively small size of the dog, and lack of evidence for complicating infection, suggest against sharp penetrating trauma as a sole cause. The most plausible differential diagnoses include: uncommon fracture-producing force in a companion animal, and blunt intrinsic or extrinsic force causing fracture at a weak point, such as an early osteochondral lesion, that was obliterated by healing. Combined gross examination, micro-computed tomography, and archeological-anthropological influences facilitated refinement of differential diagnosis. Copyright © 2013 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Hyde, B. C.; Tait, K. T.; Nicklin, I.; Day, J. M. D.; Ash, R. D.; Moser, D. E.
2013-09-01
Sectioning of meteorites is usually done in an arbitrary manner. We used micro-computed tomography to view the interior of brachinite NWA 4872. A cut was then made through an area of interest. Heterogeneity and modal abundance are discussed.
Terahertz Computed Tomography of NASA Thermal Protection System Materials
NASA Technical Reports Server (NTRS)
Roth, D. J.; Reyes-Rodriguez, S.; Zimdars, D. A.; Rauser, R. W.; Ussery, W. W.
2011-01-01
A terahertz axial computed tomography system has been developed that uses time domain measurements in order to form cross-sectional image slices and three-dimensional volume renderings of terahertz-transparent materials. The system can inspect samples as large as 0.0283 cubic meters (1 cubic foot) with no safety concerns as for x-ray computed tomography. In this study, the system is evaluated for its ability to detect and characterize flat bottom holes, drilled holes, and embedded voids in foam materials utilized as thermal protection on the external fuel tanks for the Space Shuttle. X-ray micro-computed tomography was also performed on the samples to compare against the terahertz computed tomography results and better define embedded voids. Limits of detectability based on depth and size for the samples used in this study are loosely defined. Image sharpness and morphology characterization ability for terahertz computed tomography are qualitatively described.
Sun, Yi; Wang, Chengyue; Chen, Qixin; Liu, Hai; Deng, Chao; Ling, Peixue; Cui, Fu-Zhai
2017-08-01
This study was aimed at assessing the effects of the porous mineralized collagen plug with or without the bilayer mineralized collagen-guided bone regeneration membrane on alveolar ridge preservation in dogs. The third premolars in the bilateral maxilla of mongrel dogs ( N = 12) were extracted. Twenty-four alveolar sockets were thus randomly divided into three groups: membrane + collagen plug (MP, n = 8), nonmembrane + collagen plug (NP, n = 8) and blank group without any implantation (BG, n = 8). Radiographic assessment was carried out immediately and in the 2nd, 6th, and 12th week after surgery. The bone-repairing effects of the two grafts were respectively evaluated by clinical observation, X-ray micro-computed tomography examination, and histological analysis in the 8th and 12th week after surgery. Three groups presented excellent osseointegration without any inflammation or dehiscence. X-ray micro-computed tomography and histological assessment indicated that the ratios of new bone formation of MP group were significantly higher than those of NP group and BG group in the 8th and 12th week after surgery ( P < 0.05). As a result, the porous mineralized collagen plug with or without the bilayer mineralized collagen-guided bone regeneration membrane could reduce the absorption of alveolar ridge compared to BG group, and the combined use of porous mineralized collagen plug and bilayer mineralized collagen-guided bone regeneration could further improve the activity of bone regeneration.
Spirlandeli, Adriano L.; Dick-de-Paula, Ingrid; Zamarioli, Ariane; Jorgetti, Vanda; Ramalho, Leandra N.Z.; Nogueira-Barbosa, Marcello H.; Volpon, Jose B.; Jordão, Alceu A.; Cunha, Fernando Q.; Fukada, Sandra Y.; de Paula, Francisco J.A.
2017-01-01
OBJECTIVES: The present study was designed to evaluate the bone phenotypes and mechanisms involved in bone disorders associated with hepatic osteodystrophy. Hepatocellular disease was induced by carbon tetrachloride (CCl4). In addition, the effects of disodium pamidronate on bone tissue were evaluated. METHODS: The study included 4 groups of 15 mice: a) C = mice subjected to vehicle injections; b) C+P = mice subjected to vehicle and pamidronate injections; c) CCl4+V = mice subjected to CCl4 and vehicle injections; and d) CCl4+P = mice subjected to CCl4 and pamidronate injections. CCl4 or vehicle was administered for 8 weeks, while pamidronate or vehicle was injected at the end of the fourth week. Bone histomorphometry and biomechanical analysis were performed in tibiae, while femora were used for micro-computed tomography and gene expression. RESULTS: CCl4 mice exhibited decreased bone volume/trabecular volume and trabecular numbers, as well as increased trabecular separation, as determined by bone histomorphometry and micro-computed tomography, but these changes were not detected in the group treated with pamidronate. CCl4 mice showed increased numbers of osteoclasts and resorption surface. High serum levels of receptor activator of nuclear factor-κB ligand and the increased expression of tartrate-resistant acid phosphatase in the bones of CCl4 mice supported the enhancement of bone resorption in these mice. CONCLUSION: Taken together, these results suggest that bone resorption is the main mechanism of bone loss in chronic hepatocellular disease in mice. PMID:28492723
Spirlandeli, Adriano L; Dick-de-Paula, Ingrid; Zamarioli, Ariane; Jorgetti, Vanda; Ramalho, Leandra N Z; Nogueira-Barbosa, Marcello H; Volpon, Jose B; Jordão, Alceu A; Cunha, Fernando Q; Fukada, Sandra Y; de Paula, Francisco J A
2017-04-01
The present study was designed to evaluate the bone phenotypes and mechanisms involved in bone disorders associated with hepatic osteodystrophy. Hepatocellular disease was induced by carbon tetrachloride (CCl4). In addition, the effects of disodium pamidronate on bone tissue were evaluated. The study included 4 groups of 15 mice: a) C = mice subjected to vehicle injections; b) C+P = mice subjected to vehicle and pamidronate injections; c) CCl4+V = mice subjected to CCl4 and vehicle injections; and d) CCl4+P = mice subjected to CCl4 and pamidronate injections. CCl4 or vehicle was administered for 8 weeks, while pamidronate or vehicle was injected at the end of the fourth week. Bone histomorphometry and biomechanical analysis were performed in tibiae, while femora were used for micro-computed tomography and gene expression. CCl4 mice exhibited decreased bone volume/trabecular volume and trabecular numbers, as well as increased trabecular separation, as determined by bone histomorphometry and micro-computed tomography, but these changes were not detected in the group treated with pamidronate. CCl4 mice showed increased numbers of osteoclasts and resorption surface. High serum levels of receptor activator of nuclear factor-κB ligand and the increased expression of tartrate-resistant acid phosphatase in the bones of CCl4 mice supported the enhancement of bone resorption in these mice. Taken together, these results suggest that bone resorption is the main mechanism of bone loss in chronic hepatocellular disease in mice.
Smith, Timothy D; Rossie, James B; Cooper, Gregory M; Schmieg, Robin M; Bonar, Christopher J; Mooney, Mark P; Siegel, Michael I
2011-03-01
In anthropoid primates, it has been hypothesized that the magnitude of maxillary sinus growth is influenced by adjacent dental and soft tissue matrices. Relatively, little comparative evidence exists for the perinatal period when secondary pneumatization is at its earliest stages in some primates. Here, dental and midfacial variables were studied in a perinatal sample of four anthropoid primates, including three callitrichines (Leontopithecus, Saguinus, and Callithrix) and Saimiri boliviensis. In the latter species, the maxillary recess (the ontogenetic precursor to a "true" maxillary sinus) does not undergo secondary pneumatization. Using histological methods and micro-computed tomography, midfacial and dental dimensions and radiographic hydroxyapatite density of tooth cusps were measured. The distribution of osteoclasts and osteoblasts was also documented. Kruskal-Wallis's one-way analysis of variance tests indicates significant (P < 0.05) differences among groups for dental and midfacial measurements. In particular, the posterior maxillary dentition is relatively larger and more mineralized in Saimiri compared to the callitrichines. At posterior dental levels, Saimiri has the lowest palatonasal index [interdental (palatal) width/width of the nasal cavity] and highest bizygomatic-interorbital index. Distribution of osteoclasts indicates that the inferomedial surfaces of the orbits are resorptive in perinatal Saimiri, whereas, in all callitrichines, these surfaces are depository. Taken together, these findings suggest that pneumatization in Saimiri is suppressed by an inward growth trajectory of the orbits, relatively large posterior dentition, and a correspondingly compressed nasal region. Copyright © 2010 Wiley-Liss, Inc.
Girard, Romuald; Zeineddine, Hussein A; Orsbon, Courtney; Tan, Huan; Moore, Thomas; Hobson, Nick; Shenkar, Robert; Lightle, Rhonda; Shi, Changbin; Fam, Maged D; Cao, Ying; Shen, Le; Neander, April I; Rorrer, Autumn; Gallione, Carol; Tang, Alan T; Kahn, Mark L; Marchuk, Douglas A; Luo, Zhe-Xi; Awad, Issam A
2016-09-15
Cerebral cavernous malformations (CCMs) are hemorrhagic brain lesions, where murine models allow major mechanistic discoveries, ushering genetic manipulations and preclinical assessment of therapies. Histology for lesion counting and morphometry is essential yet tedious and time consuming. We herein describe the application and validations of X-ray micro-computed tomography (micro-CT), a non-destructive technique allowing three-dimensional CCM lesion count and volumetric measurements, in transgenic murine brains. We hereby describe a new contrast soaking technique not previously applied to murine models of CCM disease. Volumetric segmentation and image processing paradigm allowed for histologic correlations and quantitative validations not previously reported with the micro-CT technique in brain vascular disease. Twenty-two hyper-dense areas on micro-CT images, identified as CCM lesions, were matched by histology. The inter-rater reliability analysis showed strong consistency in the CCM lesion identification and staging (K=0.89, p<0.0001) between the two techniques. Micro-CT revealed a 29% greater CCM lesion detection efficiency, and 80% improved time efficiency. Serial integrated lesional area by histology showed a strong positive correlation with micro-CT estimated volume (r(2)=0.84, p<0.0001). Micro-CT allows high throughput assessment of lesion count and volume in pre-clinical murine models of CCM. This approach complements histology with improved accuracy and efficiency, and can be applied for lesion burden assessment in other brain diseases. Copyright © 2016 Elsevier B.V. All rights reserved.
Ru, Nan; Liu, Sean Shih-Yao; Zhuang, Li; Li, Song; Bai, Yuxing
2013-05-01
To observe the real-time microarchitecture changes of the alveolar bone and root resorption during orthodontic treatment. A 10 g force was delivered to move the maxillary left first molars mesially in twenty 10-week-old rats for 14 days. The first molar and adjacent alveolar bone were scanned using in vivo microcomputed tomography at the following time points: days 0, 3, 7, and 14. Microarchitecture parameters, including bone volume fraction, structure model index, trabecular thickness, trabecular number, and trabecular separation of alveolar bone, were measured on the compression and tension side. The total root volume was measured, and the resorption crater volume at each time point was calculated. Univariate repeated measures analysis of variance with Bonferroni corrections were performed to compare the differences in each parameter between time points with significance level at P < .05. From day 3 to day 7, bone volume fraction, structure model index, trabecular thickness, and trabecular separation decreased significantly on the compression side, but the same parameters increased significantly on the tension side from day 7 to day 14. Root resorption volume of the mesial root increased significantly on day 7 of orthodontic loading. Real-time root and bone resorption during orthodontic movement can be observed in 3 dimensions using in vivo micro-CT. Alveolar bone resorption and root resorption were observed mostly in the apical third on day 7 on the compression side; bone formation was observed on day 14 on the tension side during orthodontic tooth movement.
Lu, Yongtao; Boudiffa, Maya; Dall'Ara, Enrico; Bellantuono, Ilaria; Viceconti, Marco
2015-11-01
In vivo micro-computed tomography (µCT) scanning is an important tool for longitudinal monitoring of the bone adaptation process in animal models. However, the errors associated with the usage of in vivo µCT measurements for the evaluation of bone adaptations remain unclear. The aim of this study was to evaluate the measurement errors using the bone surface distance approach. The right tibiae of eight 14-week-old C57BL/6 J female mice were consecutively scanned four times in an in vivo µCT scanner using a nominal isotropic image voxel size (10.4 µm) and the tibiae were repositioned between each scan. The repeated scan image datasets were aligned to the corresponding baseline (first) scan image dataset using rigid registration and a region of interest was selected in the proximal tibia metaphysis for analysis. The bone surface distances between the repeated and the baseline scan datasets were evaluated. It was found that the average (±standard deviation) median and 95th percentile bone surface distances were 3.10 ± 0.76 µm and 9.58 ± 1.70 µm, respectively. This study indicated that there were inevitable errors associated with the in vivo µCT measurements of bone microarchitecture and these errors should be taken into account for a better interpretation of bone adaptations measured with in vivo µCT. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.
2017-01-01
Purpose Optical coherence tomography (OCT) is a noninvasive diagnostic technique that may be useful for both qualitative and quantitative analyses of the periodontium. Micro-computed tomography (micro-CT) is another noninvasive imaging technique capable of providing submicron spatial resolution. The purpose of this study was to present periodontal images obtained using ex vivo dental OCT and to compare OCT images with micro-CT images and histologic sections. Methods Images of ex vivo canine periodontal structures were obtained using OCT. Biologic depth measurements made using OCT were compared to measurements made on histologic sections prepared from the same sites. Visual comparisons were made among OCT, micro-CT, and histologic sections to evaluate whether anatomical details were accurately revealed by OCT. Results The periodontal tissue contour, gingival sulcus, and the presence of supragingival and subgingival calculus could be visualized using OCT. OCT was able to depict the surface topography of the dentogingival complex with higher resolution than micro-CT, but the imaging depth was typically limited to 1.2–1.5 mm. Biologic depth measurements made using OCT were a mean of 0.51 mm shallower than the histologic measurements. Conclusions Dental OCT as used in this study was able to generate high-resolution, cross-sectional images of the superficial portions of periodontal structures. Improvements in imaging depth and the development of an intraoral sensor are likely to make OCT a useful technique for periodontal applications. PMID:28261522
Oravec, Daniel; Quazi, Abrar; Xiao, Angela; Yang, Ellen; Zauel, Roger; Flynn, Michael J; Yeni, Yener N
2015-12-01
Endplate morphology is understood to play an important role in the mechanical behavior of vertebral bone as well as degenerative processes in spinal tissues; however, the utility of clinical imaging modalities in assessment of the vertebral endplate has been limited. The objective of this study was to evaluate the ability of two clinical imaging modalities (digital tomosynthesis, DTS; high resolution computed tomography, HRCT) to assess endplate topography by correlating the measurements to a microcomputed tomography (μCT) standard. DTS, HRCT, and μCT images of 117 cadaveric thoracolumbar vertebrae (T10-L1; 23 male, 19 female; ages 36-100 years) were segmented, and inferior and superior endplate surface topographical distribution parameters were calculated. Both DTS and HRCT showed statistically significant correlations with μCT approaching a moderate level of correlation at the superior endplate for all measured parameters (R(2)Adj=0.19-0.57), including averages, variability, and higher order statistical moments. Correlation of average depths at the inferior endplate was comparable to the superior case for both DTS and HRCT (R(2)Adj=0.14-0.51), while correlations became weak or nonsignificant for higher moments of the topography distribution. DTS was able to capture variations in the endplate topography to a slightly better extent than HRCT, and taken together with the higher speed and lower radiation cost of DTS than HRCT, DTS appears preferable for endplate measurements. Copyright © 2015 Elsevier Inc. All rights reserved.
Witcomb, Luci A; Czupryna, Julie; Francis, Kevin P; Frankel, Gad; Taylor, Peter W
2017-08-15
In contrast to two-dimensional bioluminescence imaging, three dimensional diffuse light imaging tomography with integrated micro-computed tomography (DLIT-μCT) has the potential to realise spatial variations in infection patterns when imaging experimental animals dosed with derivatives of virulent bacteria carrying bioluminescent reporter genes such as the lux operon from the bacterium Photorhabdus luminescens. The method provides an opportunity to precisely localise the bacterial infection sites within the animal and enables the generation of four-dimensional movies of the infection cycle. Here, we describe the use of the PerkinElmer IVIS SpectrumCT in vivo imaging system to investigate progression of lethal systemic infection in neonatal rats following colonisation of the gastrointestinal tract with the neonatal pathogen Escherichia coli K1. We confirm previous observations that these bacteria stably colonize the colon and small intestine following feeding of the infectious dose from a micropipette; invading bacteria migrate across the gut epithelium into the blood circulation and establish foci of infection in major organs, including the brain. DLIT-μCT revealed novel multiple sites of colonisation within the alimentary canal, including the tongue, oesophagus and stomach, with penetration of the non-keratinised oesophageal epithelial surface, providing strong evidence of a further major site for bacterial dissemination. We highlight technical issues associated with imaging of infections in new born rat pups and show that the whole-body and organ bioburden correlates with disease severity. Copyright © 2017 Elsevier Inc. All rights reserved.
Amoroso-Silva, Pablo; De Moraes, Ivaldo Gomes; Marceliano-Alves, Marilia; Bramante, Clovis Monteiro; Zapata, Ronald Ordinola; Hungaro Duarte, Marco Antonio
2018-01-01
This study aimed to describe the morphological and morphometric aspects of fused mandibular second molars with radicular shallow grooves using micro-computed tomography (CT). Eighty-eight mandibular second molars with fused roots were scanned in a micro-CT scanner at a voxel size of 19.6 μm. After reconstruction, only molars without C-shaped roots and presenting shallow radicular grooves were selected. 30 molars were chosen for further analysis. Canal cross-sections were classified according to Fan's modified classification (C1, C2, C3, and C4) and morphometric parameters at the apical region, examination of accessory foramina and tridimensional configuration were evaluated. Three-dimensional reconstructions indicated a higher prevalence of merging type ( n = 22). According to Fan's modified classification, the C4 configuration was predominant in the 3 apical mm. Roundness median values revealed a more round-shaped canals at 3 mm (0.72) than at 2 (0.63) and 1 (0.61) mm from the apex. High values of major and minor diameters were observed in the canals of these evaluated sections. In addition, few accessory apical foramina were observed at 1 and 2 mm from the apex. The average distance between last accessory foramina and the anatomic apex was 1.17 mm. A less complex internal anatomy is found when a mandibular second molar presents fused roots with shallow radicular grooves. The merging type canal was frequently observed. Moreover, the C4 configuration was predominant at a point 3 mm from the apex and presented rounded canals, large apical diameters, and few accessory foramina. The cervical and middle thirds presented C3 and C1 canal configurations most frequently. A minor morphological complexity is found when fused mandibular second molars present shallow radicular grooves.
Basu, Bikramjit; Sabareeswaran, A; Shenoy, S J
2015-08-01
One of the desired properties for any new biomaterial composition is its long-term stability in a suitable animal model and such property cannot be appropriately assessed by performing short-term implantation studies. While hydroxyapatite (HA) or bioglass coated metallic biomaterials are being investigated for in vivo biocompatibility properties, such study is not extensively being pursued for bulk glass ceramics. In view of their inherent brittle nature, the implant stability as well as impact of long-term release of metallic ions on bone regeneration have been a major concern. In this perspective, the present article reports the results of the in vivo implantation experiments carried out using 100% strontium (Sr)-substituted glass ceramics with the nominal composition of 4.5 SiO2 -3Al2 O3 -1.5P2 O5 -3SrO-2SrF2 for 26 weeks in cylindrical bone defects in rabbit model. The combination of histological and micro-computed tomography analysis provided a qualitative and quantitative understanding of the bone regeneration around the glass ceramic implants in comparison to the highly bioactive HA bioglass implants (control). The sequential polychrome labeling of bone during in vivo osseointegration using three fluorochromes followed by fluorescence microscopy observation confirmed homogeneous bone formation around the test implants. The results of the present study unequivocally confirm the long-term implant stability as well as osteoconductive property of 100% Sr-substituted glass ceramics, which is comparable to that of a known bioactive implant, that is, HA-based bioglass. © 2014 Wiley Periodicals, Inc.
Xiao, J; Zhou, H; Zhao, L; Sun, Y; Guan, S; Liu, B; Kong, L
2011-06-01
Hydrofluoric etching and anodized hierarchical micro/nanotextured surface titanium implant was placed in mandibles of ovariectomized sheep for 12 weeks, and it showed improved osseointegration by resonance frequency analysis (RFA), microcomputed tomography (micro-CT) evaluation, histomorphometry, and biomechanical test. This study aimed to investigate the effects of micro/nanotextured titanium implant on osseointegration in ovariectomized (OVX) sheep. The hierarchical micro/nanotextured surface of titanium implant was fabricated by acid in 0.5% (w/v) hydrofluoric (HF) and anodized in HF acid electrolytes with a DC power of 20 V, and the machined surface implants with no treatment served as control group. The implants were placed in mandibles of OVX sheep, respectively. Twelve weeks after implantation, RFA, microcomputed tomography, histomorphometry, and biomechanical tests were applied to detect the osseointegration of the two groups. The implant stability quotient (ISQ) values, the maximum pull-out forces, and the bone-implant contact (BIC) were 65.5 ± 6.3, 490.6 ± 72.7 N, and 58.31 ± 5.79% in the micro/nanogroup and 58.3 ± 8.9, 394.5 ± 54.5 N, and 46.85 ± 5.04% in the control group, respectively. There was no significant difference between the two groups in ISQ values (p > 0.05), but in the micro/nanogroup, the maximal pull-out force and the BIC were increased significantly (p < 0.05 or p < 0.01). Micro-CT analysis showed that the bone volume ratio and the trabecular number increased significantly (p < 0.01), and the trabecular separation decreased significantly (p < 0.05) in the micro/nanogroup. Implant modification by HF acid etching and anodization to form a hierarchical micro/nanotextured surface could improve titanium implant osseointegration in OVX sheep 12 weeks after implantation.
Jörn, Daniela; Kohorst, Philipp; Besdo, Silke; Borchers, Lothar; Stiesch, Meike
2016-01-01
Since bacterial leakage along the implant-abutment interface may be responsible for peri-implant infections, a realistic estimation of the interface gap width during function is important for risk assessment. The purpose of this study was to compare two methods for investigating microgap formation in a loaded dental implant, namely, microcomputed tomography (micro-CT) and three-dimensional (3D) nonlinear finite element analysis (FEA); additionally, stresses to be expected during loading were also evaluated by FEA. An implant-abutment complex was inspected for microgaps between the abutment and implant in a micro-CT scanner under an oblique load of 200 N. A numerical model of the situation was constructed; boundary conditions and external load were defined according to the experiment. The model was refined stepwise until its load-displacement behavior corresponded sufficiently to data from previous load experiments. FEA of the final, validated model was used to determine microgap widths. These were compared with the widths as measured in micro-CT inspection. Finally, stress distributions were evaluated in selected regions. No microgaps wider than 13 μm could be detected by micro-CT for the loaded implant. FEA revealed gap widths up to 10 μm between the implant and abutment at the side of load application. Furthermore, FEA predicted plastic deformation in a limited area at the implant collar. FEA proved to be an adequate method for studying microgap formation in dental implant-abutment complexes. FEA is not limited in gap width resolution as are radiologic techniques and can also provide insight into stress distributions within the loaded complex.
Attenuation Drift in the Micro-Computed Tomography System at LLNL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dooraghi, Alex A.; Brown, William; Seetho, Isaac
2016-01-12
The maximum allowable level of drift in the linear attenuation coefficients (μ) for a Lawrence Livermore National Laboratory (LLNL) micro-computed tomography (MCT) system was determined to be 0.1%. After ~100 scans were acquired during the period of November 2014 to March 2015, the drift in μ for a set of six reference materials reached or exceeded 0.1%. Two strategies have been identified to account for or correct the drift. First, normalizing the 160 kV and 100 kV μ data by the μ of water at the corresponding energy, in contrast to conducting normalization at the 160 kV energy only, significantlymore » compensates for measurement drift. Even after the modified normalization, μ of polytetrafluoroethylene (PTFE) increases linearly with scan number at an average rate of 0.00147% per scan. This is consistent with PTFE radiation damage documented in the literature. The second strategy suggested is the replacement of the PTFE reference with fluorinated ethylene propylene (FEP), which has the same effective atomic number (Ze) and electron density (ρe) as PTFE, but is 10 times more radiation resistant. This is important as effective atomic number and electron density are key parameters in analysis. The presence of a material with properties such as PTFE, when taken together with the remaining references, allows for a broad range of the (Ze, ρe) feature space to be used in analysis. While FEP is documented as 10 times more radiation resistant, testing will be necessary to assess how often, if necessary, FEP will need to be replaced. As radiation damage to references has been observed, it will be necessary to monitor all reference materials for radiation damage to ensure consistent x-ray characteristics of the references.« less
NASA Astrophysics Data System (ADS)
Chan, P.; Halfar, J.; Norley, C. J. D.; Pollmann, S. I.; Adey, W.; Holdsworth, D. W.
2017-09-01
Warming and acidification of the world's oceans are expected to have widespread consequences for marine biodiversity and ecosystem functioning. However, due to the relatively short record of instrumental observations, one has to rely upon geochemical and physical proxy information stored in biomineralized shells and skeletons of calcareous marine organisms as in situ recorders of past environments. Of particular interest is the response of marine calcifiers to ocean acidification through the examination of structural growth characteristics. Here we demonstrate the application of micro-computed tomography (micro-CT) for three-dimensional visualization and analysis of growth, skeletal density, and calcification in a slow-growing, annually banded crustose coralline alga Clathromorphum nereostratum (increment width ˜380 µm). X-ray images and time series of skeletal density were generated at 20 µm resolution and rebinned to 40, 60, 80, and 100 µm for comparison in a sensitivity analysis. Calcification rates were subsequently calculated as the product of density and growth (linear extension). While both skeletal density and calcification rates do not significantly differ at varying spatial resolutions (the latter being strongly influenced by growth rates), clear visualization of micron-scale growth features and the quantification of structural changes on subannual time scales requires higher scanning resolutions. In the present study, imaging at 20 µm resolution reveals seasonal cycles in density that correspond to summer/winter variations in skeletal structure observed using scanning electron microscopy (SEM). Micro-CT is a fast, nondestructive, and high-resolution technique for structural and morphometric analyses of temporally banded paleoclimate archives, particularly those that exhibit slow or compressed growth or micron-scale structures.
Stringheta, Carolina Pessoa; Pelegrine, Rina Andréa; Kato, Augusto Shoji; Freire, Laila Gonzales; Iglecias, Elaine Faga; Gavini, Giulio; Bueno, Carlos Eduardo da Silveira
2017-12-01
The objective of this study was to compare the methods of micro-computed tomography (micro-CT) and cross-sectioning followed by stereomicroscopy in assessing dentinal defects after instrumentation with different mechanized systems. Forty mesial roots of mandibular molars were scanned and divided into 4 groups (n = 10): Group R, Reciproc; Group PTN, ProTaper Next; Group WOG, WaveOne Gold; Group PDL, ProDesign Logic. After instrumentation, the roots were once again submitted to a micro-CT scan, and then sectioned at 3, 6, and 9 mm from the apex, and assessed for the presence of complete and incomplete dentinal defects under a stereomicroscope. The nonparametric Kruskal-Wallis, Friedman, and Wilcoxon tests were used in the statistical analysis. The study used a significance level of 5%. The total number of defects observed by cross-sectioning followed by stereomicroscopy was significantly higher than that observed by micro-CT, in all of the experimental groups (P ≤ .05). All of the defects identified in the postoperative period were already present in the corresponding preoperative period. There was no significant difference among the instrumentation systems as to the median numbers of defects, for either cross-sectioning followed by stereomicroscopy or micro-CT, at all the root levels (P > .05). In the micro-CT analysis, no significant difference was found between the median numbers of pre- and postinstrumentation defects, regardless of the instrumentation system (P > .05). None of the evaluated instrumentation systems led to the formation of new dentin defects. All of the defects identified in the stereomicroscopic analysis were already present before instrumentation, or were absent at both time points in the micro-CT analysis, indicating that the formation of new defects resulted from the sectioning procedure performed before stereomicroscopy and not from instrumentation. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Downey, Charlene M; Singla, Arvind K; Villemaire, Michelle L; Buie, Helen R; Boyd, Steven K; Jirik, Frank R
2012-01-01
Techniques for visualizing and quantifying the microvasculature of tumors are essential not only for studying angiogenic processes but also for monitoring the effects of anti-angiogenic treatments. Given the relatively limited information that can be gleaned from conventional 2-D histological analyses, there has been considerable interest in methods that enable the 3-D assessment of the vasculature. To this end, we employed a polymerizing intravascular contrast medium (Microfil) and micro-computed tomography (micro-CT) in combination with a maximal spheres direct 3-D analysis method to visualize and quantify ex-vivo vessel structural features, and to define regions of hypoperfusion within tumors that would be indicative of necrosis. Employing these techniques we quantified the effects of a vascular disrupting agent on the tumor vasculature. The methods described herein for quantifying whole tumor vascularity represent a significant advance in the 3-D study of tumor angiogenesis and evaluation of novel therapeutics, and will also find potential application in other fields where quantification of blood vessel structure and necrosis are important outcome parameters.
Wyatt, S K; Barck, K H; Kates, L; Zavala-Solorio, J; Ross, J; Kolumam, G; Sonoda, J; Carano, R A D
2015-11-01
The ability to non-invasively measure body composition in mouse models of obesity and obesity-related disorders is essential for elucidating mechanisms of metabolic regulation and monitoring the effects of novel treatments. These studies aimed to develop a fully automated, high-throughput micro-computed tomography (micro-CT)-based image analysis technique for longitudinal quantitation of adipose, non-adipose and lean tissue as well as bone and demonstrate utility for assessing the effects of two distinct treatments. An initial validation study was performed in diet-induced obesity (DIO) and control mice on a vivaCT 75 micro-CT system. Subsequently, four groups of DIO mice were imaged pre- and post-treatment with an experimental agonistic antibody specific for anti-fibroblast growth factor receptor 1 (anti-FGFR1, R1MAb1), control immunoglobulin G antibody, a known anorectic antiobesity drug (rimonabant, SR141716), or solvent control. The body composition analysis technique was then ported to a faster micro-CT system (CT120) to markedly increase throughput as well as to evaluate the use of micro-CT image intensity for hepatic lipid content in DIO and control mice. Ex vivo chemical analysis and colorimetric analysis of the liver triglycerides were performed as the standard metrics for correlation with body composition and hepatic lipid status, respectively. Micro-CT-based body composition measures correlate with ex vivo chemical analysis metrics and enable distinction between DIO and control mice. R1MAb1 and rimonabant have differing effects on body composition as assessed by micro-CT. High-throughput body composition imaging is possible using a modified CT120 system. Micro-CT also provides a non-invasive assessment of hepatic lipid content. This work describes, validates and demonstrates utility of a fully automated image analysis technique to quantify in vivo micro-CT-derived measures of adipose, non-adipose and lean tissue, as well as bone. These body composition metrics highly correlate with standard ex vivo chemical analysis and enable longitudinal evaluation of body composition and therapeutic efficacy monitoring.
NASA Astrophysics Data System (ADS)
Zhou, H.; Yu, X.; Chen, C.; Zeng, L.; Lu, S.; Wu, L.
2016-12-01
In this research, we combined synchrotron-based X-ray micro-computed tomography (SR-mCT), with three-dimensional lattice Bolzmann (LB) method, to quantify how the change in pore space architecture affected macroscopic hydraulic of two clayey soils amended with biochar. SR-mCT was used to characterize pore structures of the soils before and after biochar addition. The high-resolution soil pore structures were then directly used as internal boundary conditions for three-dimensional water flow simulations with the LB method, which was accelerated by graphics processing unit (GPU) parallel computing. It was shown that, due to the changes in soil pore geometry, the application of biochar increased the soil permeability by at least 1 order of magnitude, and decreased the tortuosity by 20-30%. This work was the first physics based modeling study on the effect of biochar amendment on soil hydraulic properties. The developed theories and techniques have promising potential in understanding the mechanisms of water and nutrient transport in soil at the pore scale.
Application of X-ray micro-computed tomography on high-speed cavitating diesel fuel flows
NASA Astrophysics Data System (ADS)
Mitroglou, N.; Lorenzi, M.; Santini, M.; Gavaises, M.
2016-11-01
The flow inside a purpose built enlarged single-orifice nozzle replica is quantified using time-averaged X-ray micro-computed tomography (micro-CT) and high-speed shadowgraphy. Results have been obtained at Reynolds and cavitation numbers similar to those of real-size injectors. Good agreement for the cavitation extent inside the orifice is found between the micro-CT and the corresponding temporal mean 2D cavitation image, as captured by the high-speed camera. However, the internal 3D structure of the developing cavitation cloud reveals a hollow vapour cloud ring formed at the hole entrance and extending only at the lower part of the hole due to the asymmetric flow entry. Moreover, the cavitation volume fraction exhibits a significant gradient along the orifice volume. The cavitation number and the needle valve lift seem to be the most influential operating parameters, while the Reynolds number seems to have only small effect for the range of values tested. Overall, the study demonstrates that use of micro-CT can be a reliable tool for cavitation in nozzle orifices operating under nominal steady-state conditions.
Zhao, Feng; Wang, Chuan; Fan, Yubo
2015-01-01
Wear of polyethylene (PE) tibial inserts is a significant cause of implant failure of total knee arthroplasty (TKA). PE inserts wear measurement and evaluation is the key in TKA researches. There are many methods to measure insert wear. Qualitative methods such as observation are used to determine the wear and its type. Quantitative methods such as gravimetric analysis, coordinate measuring machines (CMM) and micro-computed tomography (micro-CT) are used to measure the mass, volume and geometry of wear. In this paper, the principle, characteristics and research progress of main insert wear evaluation method were introduced and the problems and disadvantages were analyzed.
Morgan, Elise F.; Mason, Zachary D.; Chien, Karen B.; Pfeiffer, Anthony J.; Barnes, George L.; Einhorn, Thomas A.; Gerstenfeld, Louis C.
2009-01-01
Non-invasive characterization of fracture callus structure and composition may facilitate development of surrogate measures of the regain of mechanical function. As such, quantitative computed tomography- (CT-) based analyses of fracture calluses could enable more reliable clinical assessments of bone healing. Although previous studies have used CT to quantify and predict fracture healing, it is unclear which of the many CT-derived metrics of callus structure and composition are the most predictive of callus mechanical properties. The goal of this study was to identify the changes in fracture callus structure and composition that occur over time and that are most closely related to the regain of mechanical function. Micro-computed tomography (μCT) imaging and torsion testing were performed on murine fracture calluses (n=188) at multiple post-fracture timepoints and under different experimental conditions that alter fracture healing. Total callus volume (TV), mineralized callus volume (BV), callus mineralized volume fraction (BV/TV), bone mineral content (BMC), tissue mineral density (TMD), standard deviation of mineral density (σTMD), effective polar moment of inertia (Jeff), torsional strength, and torsional rigidity were quantified. Multivariate statistical analyses, including multivariate analysis of variance, principal components analysis, and stepwise regression were used to identify differences in callus structure and composition among experimental groups and to determine which of the μCT outcome measures were the strongest predictors of mechanical properties. Although calluses varied greatly in the absolute and relative amounts of mineralized tissue (BV, BMC, and BV/TV), differences among timepoints were most strongly associated with changes in tissue mineral density. Torsional strength and rigidity were dependent on mineral density as well as the amount of mineralized tissue: TMD, BV, and σTMD explained 62% of the variation in torsional strength (p<0.001); and TMD, BMC, BV/TV, and σTMD explained 70% of the variation in torsional rigidity (p<0.001). These results indicate that fracture callus mechanical properties can be predicted by several μCT-derived measures of callus structure and composition. These findings form the basis for developing non-invasive assessments of fracture healing and for identifying biological and biomechanical mechanisms that lead to impaired or enhanced healing. PMID:19013264
Yildirim, Güler; Uzun, Ismail H; Keles, Ali
2017-08-01
The accuracy of recently introduced chairside computer-aided design and computer-aided manufacturing (CAD-CAM) blocks is not well established, and marginal integrity and internal adaptation are not known. The purpose of this in vitro study was to evaluate the marginal and internal adaptation of hybrid and nanoceramics using microcomputed tomography (μ-CT). The marginal and internal adaptation of 3 polymer-infiltrated ceramic-network (PICN) materials (Vita Enamic [VE]; Lava Ultimate [LU]; Vita Suprinity [VS]) were compared with lithium disilicate (IPS e.max.CAD, IPS). Ninety-six specimens (48 dies and 48 crowns) were prepared (n=12 each group) using a chairside CAD-CAM system. The restorations were scanned with μ-CT, with 160 measurements made for each crown, and used in 2-dimensional (2D) analysis. The marginal adaptation of marginal discrepancy (MD), absolute marginal discrepancy (AMD), internal adaptation of shoulder area (SA), axial space (AS), and occlusal space (OS) were compared using appropriate statistical analysis methods (α=.05). Cement volumes were compared using 3D analysis. The IPS blocks showed higher MD (130 μm), AMD (156 μm), SA (111 μm) (P<.05), AS (52 μm), and OS (192 μm) than the other blocks (P<.01). The adaptation values of VS were significantly lower than those of the IPS block (P<.05). The adaption values of the LU and VE blocks were significantly lower than those of others (P<.01) but were statistically similar to one another (P>.05). IPS had the largest cement space at 18 mm 3 (P<.01). The marginal and internal adaptation values were within a clinically acceptable range for all 3 hybrids and nanoceramics tested. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Tools for Scientific Thinking: Microcomputer-Based Laboratories for the Naive Science Learner.
ERIC Educational Resources Information Center
Thornton, Ronald K.
A promising new development in science education is the use of microcomputer-based laboratory tools that allow for student-directed data acquisition, display, and analysis. Microcomputer-based laboratories (MBL) make use of inexpensive microcomputer-connected probes to measure such physical quantities as temperature, position, and various…
Paqué, Frank; Peters, Ove A
2011-04-01
The aim of this study was to assess the shaping potential of a novel nickel-titanium instrument, the self-adjusting file (SAF), in long oval root canals in distal roots in mandibular molars. Twenty mandibular molars with long oval distal root canals were selected and scanned preoperatively and postoperatively by using micro-computed tomography at an original resolution of 20 μm. Canals were shaped with the SAF, three-dimensionally reconstructed, and evaluated for volume, surface area, canal transportation, and prepared surface. Data were statistically contrasted by using paired t tests and regression analysis. Preoperatively, canal volume was 7.73 ± 2.13 mm(3), and canal area was 42.83 ± 8.14 mm(2). Volumes and surface areas increased significantly (P < .001) by 4.84 ± 1.73 mm(3) and 3.34 ± 1.73 mm(2), respectively, and no gross preparation errors were detected. Unprepared canal surface varied between individual canals, and mean unprepared surface was 23.5% ± 8.9%. Prepared areas were significantly larger compared with rotary canal preparation done in a previous study. Canal transportation scores were higher in the coronal root canal third (106 ± 50 μm) compared with the apical third (81 ± 49 μm). In vitro, preparation of long oval-shaped root canals in mandibular molars with the SAF was effective and safe. Moreover, shapes generated with the SAF were more complete compared with rotary canal preparation. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Accurate micro-computed tomography imaging of pore spaces in collagen-based scaffold.
Zidek, Jan; Vojtova, Lucy; Abdel-Mohsen, A M; Chmelik, Jiri; Zikmund, Tomas; Brtnikova, Jana; Jakubicek, Roman; Zubal, Lukas; Jan, Jiri; Kaiser, Jozef
2016-06-01
In this work we have used X-ray micro-computed tomography (μCT) as a method to observe the morphology of 3D porous pure collagen and collagen-composite scaffolds useful in tissue engineering. Two aspects of visualizations were taken into consideration: improvement of the scan and investigation of its sensitivity to the scan parameters. Due to the low material density some parts of collagen scaffolds are invisible in a μCT scan. Therefore, here we present different contrast agents, which increase the contrast of the scanned biopolymeric sample for μCT visualization. The increase of contrast of collagenous scaffolds was performed with ceramic hydroxyapatite microparticles (HAp), silver ions (Ag(+)) and silver nanoparticles (Ag-NPs). Since a relatively small change in imaging parameters (e.g. in 3D volume rendering, threshold value and μCT acquisition conditions) leads to a completely different visualized pattern, we have optimized these parameters to obtain the most realistic picture for visual and qualitative evaluation of the biopolymeric scaffold. Moreover, scaffold images were stereoscopically visualized in order to better see the 3D biopolymer composite scaffold morphology. However, the optimized visualization has some discontinuities in zoomed view, which can be problematic for further analysis of interconnected pores by commonly used numerical methods. Therefore, we applied the locally adaptive method to solve discontinuities issue. The combination of contrast agent and imaging techniques presented in this paper help us to better understand the structure and morphology of the biopolymeric scaffold that is crucial in the design of new biomaterials useful in tissue engineering.
Stewart, Suzanne; Barr, Stephanie; Engiles, Julie; Hickok, Noreen J; Shapiro, Irving M; Richardson, Dean W; Parvizi, Javad; Schaer, Thomas P
2012-08-01
Implant-associated infections contribute to patient morbidity and health care costs. We hypothesized that surface modification of titanium fracture hardware with vancomycin would support bone-healing and prevent bacterial colonization of the implant in a large-animal model. A unilateral transverse mid-diaphyseal tibial osteotomy was performed and repaired with a titanium locking compression plate in nine sheep. Four control animals were treated with an unmodified plate and five experimental animals were treated with a vancomycin-modified plate. The osteotomy was inoculated with 2.5 × 106 colony-forming units of Staphylococcus aureus. The animals were killed at three months postoperatively, and implants were retrieved aseptically. Microbiologic and histologic analyses, scanning electron and confocal microscopy, and microcomputed tomography were performed. All animals completed the study. Compared with the treatment cohort, control animals exhibited protracted lameness in the operatively treated leg. Gross findings during necropsy were consistent with an infected osteotomy accompanied by a florid and lytic callus. Microcomputed tomography and histologic analysis of the tibiae further supported the presence of septic osteomyelitis in the control cohort. Thick biofilms were also evident, and bacterial cultures were positive for Staphylococcus aureus in three of four control animals. In contrast, animals treated with vancomycin-treated plates exhibited a healed osteotomy site with homogenous remodeling, there was no evidence of biofilm formation on the retrieved plate, and bacterial cultures from only one of five animals were positive for Staphylococcus aureus. Vancomycin-derivatized plate surfaces inhibited implant colonization with Staphylococcus aureus and supported bone-healing in an infected large-animal model.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arifvianto, B., E-mail: b.arifvianto@tudelft.nl; L
The present research was aimed at gaining an understanding of the porous structure changes from the green body through water leaching and sintering to titanium scaffolds. Micro-computed tomography (micro-CT) was performed to generate 3D models of titanium scaffold preforms containing carbamide space-holding particles and sintered scaffolds containing macro- and micro-pores. The porosity values and structural parameters were determined by means of image analysis. The result showed that the porosity values, macro-pore sizes, connectivity densities and specific surface areas of the titanium scaffolds sintered at 1200 °C for 3 h did not significantly deviate from those of the green structures withmore » various volume fractions of the space holder. Titanium scaffolds with a maximum specific surface area could be produced with an addition of 60–65 vol% carbamide particles to the matrix powder. The connectivity of pores inside the scaffold increased with rising volume fraction of the space holder. The shrinkage of the scaffolds prepared with > 50 vol% carbamide space holder, occurring during sintering, was caused by the reductions of macro-pore sizes and micro-pore sizes as well as the thickness of struts. In conclusion, the final porous structural characteristics of titanium scaffolds could be estimated from those of the green body. - Highlights: •Porous structures of green body and sintered titanium scaffolds was studied. •Porous structures of both samples were quantitatively characterized with micro-CT. •Porous structures of scaffolds could be controlled from the green body. •Shrinkage mechanisms of titanium scaffolds during sintering was established.« less
Peters, Ove A; Boessler, Claudia; Paqué, Frank
2010-06-01
The aim of this part of an ongoing study was to describe the dentin removal ability of a novel nickel-titanium instrument, the self-adjusting file (SAF), by using micro-computed tomography. Twenty maxillary incisors were scanned preoperatively at 20-microm resolution and postoperatively after up to 6 minutes of preparation with an SAF with 1.5-mm or 2-mm diameter. SAFs were operated with continuous irrigation in a handpiece that provided an oscillating, in-and-out movement. Changes in canal volume compared with preoperative values as well as unprepared canal surface area were determined. Data were normally distributed and compared by analysis of variance and regression analyses. Preoperatively canal volumes were statistically similar in both groups (9.86 +/- 3.97 mm3 and 9.80 +/- 2.67 mm3). Volumes increased during preparation to 13.58 +/- 3.85 mm3 (after 6 minutes with SAF 1.5 mm) and 16.43 +/- 3.64 mm3 (after 5 minutes with SAF 2.0 mm), and overall canal shapes were adequate. Unprepared canal surface area decreased from 63.0% +/- 15.1% (2 minutes with SAF 1.5 mm) to 8.6% +/- 4.1% (5 minutes with SAF 2.0 mm). Preparation of straight root canals in maxillary anterior teeth left little canal surface uninstrumented after shaping with the SAF. The timeframe of clinical application will depend on the amount of desired dentin removal and done with an SAF selected on the basis of apical gauging. Copyright 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Pérez, A R; Alves, F R F; Marceliano-Alves, M F; Provenzano, J C; Gonçalves, L S; Neves, A A; Siqueira, J F
2018-06-01
To evaluate the effects of progressive apical enlargement on the amount of unprepared root canal surface area and remaining dentine thickness. The root canals of 30 extracted mandibular incisors with Vertucci's type I configuration were instrumented with rotary HyFlex CM instruments (Coltene-Whaledent, Altstätten, Switzerland) up to 4 instruments larger than the first one that bound at the working length (WL). Teeth were scanned in a micro-computed tomography (micro-CT) device before canal preparation and after instrumentation with the 2nd, 3rd and 4th larger instruments. The amount of unprepared surface area in the full canal or in the apical 4 mm as well as the remaining dentine thickness at 10 mm from the WL were calculated and compared. The general linear model for repeated measures adjusted by Bonferroni's post hoc test was used for statistic analysis. There was a significant reduction in the amount of unprepared areas after each increase in preparation size (P < 0.01). This was observed for both the full canal length and the 4-mm apical segment. The amount of remaining dentine was also significantly reduced after each file size (P < 0.01). However, dentine thickness always remained greater than 1 mm, even after using the largest instrument. Apical preparations up to 4 instruments larger than the first one to bind at the WL caused a significant progressive reduction in the unprepared canal area. © 2017 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Potential Therapeutic Use of Relaxin in Healing Cranial Bone Defects
2016-08-01
successful production of chimeric mice after irradiation and GFP+ bone marrow transplantation; reproducible implementation of uniform cranial lesions of ~1.5...cranial defect model in chimeric mice transplanted with GFP+ bone marrow. We follow defect closure by three dimensional microcomputed tomography (µCT...histolomorphometry and immunohistochemistry, respectively. 2. Keywords GFP+ chimeric mice, cranial defect closure, relaxin, angiogenesis
NASA Astrophysics Data System (ADS)
Sheppard, Adrian; Latham, Shane; Middleton, Jill; Kingston, Andrew; Myers, Glenn; Varslot, Trond; Fogden, Andrew; Sawkins, Tim; Cruikshank, Ron; Saadatfar, Mohammad; Francois, Nicolas; Arns, Christoph; Senden, Tim
2014-04-01
This paper reports on recent advances at the micro-computed tomography facility at the Australian National University. Since 2000 this facility has been a significant centre for developments in imaging hardware and associated software for image reconstruction, image analysis and image-based modelling. In 2010 a new instrument was constructed that utilises theoretically-exact image reconstruction based on helical scanning trajectories, allowing higher cone angles and thus better utilisation of the available X-ray flux. We discuss the technical hurdles that needed to be overcome to allow imaging with cone angles in excess of 60°. We also present dynamic tomography algorithms that enable the changes between one moment and the next to be reconstructed from a sparse set of projections, allowing higher speed imaging of time-varying samples. Researchers at the facility have also created a sizeable distributed-memory image analysis toolkit with capabilities ranging from tomographic image reconstruction to 3D shape characterisation. We show results from image registration and present some of the new imaging and experimental techniques that it enables. Finally, we discuss the crucial question of image segmentation and evaluate some recently proposed techniques for automated segmentation.
High resolution 3D laboratory x-ray tomography data of femora from young, 1-14 day old C57BL/6 mice.
Bortel, Emely L; Duda, Georg N; Mundlos, Stefan; Willie, Bettina M; Fratzl, Peter; Zaslansky, Paul
2015-09-01
This data article contains high resolution (1.2 µm effective pixel size) lab-based micro-computed tomography (µCT) reconstructed volume data of the femoral mid-shafts from young C57BL/6 mice. This data formed the basis for the analyses of bone structural development in healthy mice, including closed and open porosity as reported in Bortel et al. [1]. The data reveals changes seen in bone material and porosity distribution observed when mouse bones transform from porous scaffolds into solid structures during normal organogenesis.
A manual for microcomputer image analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rich, P.M.; Ranken, D.M.; George, J.S.
1989-12-01
This manual is intended to serve three basic purposes: as a primer in microcomputer image analysis theory and techniques, as a guide to the use of IMAGE{copyright}, a public domain microcomputer program for image analysis, and as a stimulus to encourage programmers to develop microcomputer software suited for scientific use. Topics discussed include the principals of image processing and analysis, use of standard video for input and display, spatial measurement techniques, and the future of microcomputer image analysis. A complete reference guide that lists the commands for IMAGE is provided. IMAGE includes capabilities for digitization, input and output of images,more » hardware display lookup table control, editing, edge detection, histogram calculation, measurement along lines and curves, measurement of areas, examination of intensity values, output of analytical results, conversion between raster and vector formats, and region movement and rescaling. The control structure of IMAGE emphasizes efficiency, precision of measurement, and scientific utility. 18 refs., 18 figs., 2 tabs.« less
A method for evaluating the murine pulmonary vasculature using micro-computed tomography.
Phillips, Michael R; Moore, Scott M; Shah, Mansi; Lee, Clara; Lee, Yueh Z; Faber, James E; McLean, Sean E
2017-01-01
Significant mortality and morbidity are associated with alterations in the pulmonary vasculature. While techniques have been described for quantitative morphometry of whole-lung arterial trees in larger animals, no methods have been described in mice. We report a method for the quantitative assessment of murine pulmonary arterial vasculature using high-resolution computed tomography scanning. Mice were harvested at 2 weeks, 4 weeks, and 3 months of age. The pulmonary artery vascular tree was pressure perfused to maximal dilation with a radio-opaque casting material with viscosity and pressure set to prevent capillary transit and venous filling. The lungs were fixed and scanned on a specimen computed tomography scanner at 8-μm resolution, and the vessels were segmented. Vessels were grouped into categories based on lumen diameter and branch generation. Robust high-resolution segmentation was achieved, permitting detailed quantitation of pulmonary vascular morphometrics. As expected, postnatal lung development was associated with progressive increase in small-vessel number and arterial branching complexity. These methods for quantitative analysis of the pulmonary vasculature in postnatal and adult mice provide a useful tool for the evaluation of mouse models of disease that affect the pulmonary vasculature. Copyright © 2016 Elsevier Inc. All rights reserved.
School Uses of Microcomputers: Reports from a National Survey. Issue No. 5.
ERIC Educational Resources Information Center
Johns Hopkins Univ., Baltimore, MD. Center for Social Organization of Schools.
School location of microcomputers and its impact on use were examined using data from the National Survey of School Uses of Microcomputers. An analysis of the responses from 1,082 (68% of the sample) microcomputer-using, public and non-public, elementary and secondary schools surveyed between December 1982 and March 1983, suggests that where…
USDA-ARS?s Scientific Manuscript database
We investigated the effects of diet (AIN93G or high-fat), physical activity (sedentary or voluntary running) and protein source (casein or soy protein isolate) and their interactions on bone microstructural changes in distal femurs in male C57BL/6 mice by using micro-computed tomography. After 14 w...
Mok, Pooi Ling; Leow, Sue Ngein; Koh, Avin Ee-Hwan; Mohd Nizam, Hairul Harun; Ding, Suet Lee Shirley; Luu, Chi; Ruhaslizan, Raduan; Wong, Hon Seng; Halim, Wan Haslina Wan Abdul; Ng, Min Hwei; Idrus, Ruszymah Binti Hj; Chowdhury, Shiplu Roy; Bastion, Catherine Mae-Lynn; Subbiah, Suresh Kumar; Higuchi, Akon; Alarfaj, Abdullah A; Then, Kong Yong
2017-02-08
Mesenchymal stem cells are widely used in many pre-clinical and clinical settings. Despite advances in molecular technology; the migration and homing activities of these cells in in vivo systems are not well understood. Labelling mesenchymal stem cells with gold nanoparticles has no cytotoxic effect and may offer suitable indications for stem cell tracking. Here, we report a simple protocol to label mesenchymal stem cells using 80 nm gold nanoparticles. Once the cells and particles were incubated together for 24 h, the labelled products were injected into the rat subretinal layer. Micro-computed tomography was then conducted on the 15th and 30th day post-injection to track the movement of these cells, as visualized by an area of hyperdensity from the coronal section images of the rat head. In addition, we confirmed the cellular uptake of the gold nanoparticles by the mesenchymal stem cells using transmission electron microscopy. As opposed to other methods, the current protocol provides a simple, less labour-intensive and more efficient labelling mechanism for real-time cell tracking. Finally, we discuss the potential manipulations of gold nanoparticles in stem cells for cell replacement and cancer therapy in ocular disorders or diseases.
Mok, Pooi Ling; Leow, Sue Ngein; Koh, Avin Ee-Hwan; Mohd Nizam, Hairul Harun; Ding, Suet Lee Shirley; Luu, Chi; Ruhaslizan, Raduan; Wong, Hon Seng; Halim, Wan Haslina Wan Abdul; Ng, Min Hwei; Idrus, Ruszymah Binti Hj.; Chowdhury, Shiplu Roy; Bastion, Catherine Mae-Lynn; Subbiah, Suresh Kumar; Higuchi, Akon; Alarfaj, Abdullah A.; Then, Kong Yong
2017-01-01
Mesenchymal stem cells are widely used in many pre-clinical and clinical settings. Despite advances in molecular technology; the migration and homing activities of these cells in in vivo systems are not well understood. Labelling mesenchymal stem cells with gold nanoparticles has no cytotoxic effect and may offer suitable indications for stem cell tracking. Here, we report a simple protocol to label mesenchymal stem cells using 80 nm gold nanoparticles. Once the cells and particles were incubated together for 24 h, the labelled products were injected into the rat subretinal layer. Micro-computed tomography was then conducted on the 15th and 30th day post-injection to track the movement of these cells, as visualized by an area of hyperdensity from the coronal section images of the rat head. In addition, we confirmed the cellular uptake of the gold nanoparticles by the mesenchymal stem cells using transmission electron microscopy. As opposed to other methods, the current protocol provides a simple, less labour-intensive and more efficient labelling mechanism for real-time cell tracking. Finally, we discuss the potential manipulations of gold nanoparticles in stem cells for cell replacement and cancer therapy in ocular disorders or diseases. PMID:28208719
Tobita, Kenji; Matsumoto, Takuya; Ohashi, Satoru; Bessho, Masahiko; Kaneko, Masako; Ohnishi, Isao
2012-07-01
It has been previously demonstrated that low-intensity pulsed ultrasound stimulation (LIPUS) enhances formation of the medullary canal and cortex in a gap-healing model of the tibia in rabbits, shortens the time required for remodeling, and enhances mineralization of the callus. In the current study, the mechanical integrity of these models was confirmed. In order to do this, the cross-sectional moment of inertia (CSMI) obtained from quantitative micro-computed tomography scans was calculated, and a comparison was made with a four-point bending test. This parameter can be analyzed in any direction, and three directions were selected in order to adopt an XYZ coordinate (X and Y for bending; Z for torsion). The present results demonstrated that LIPUS improved earlier restoration of bending stiffness at the healing site. In addition, LIPUS was effective not only in the ultrasound-irradiated plane, but also in the other two planes. CSMI may provide the structural as well as compositional determinants to assess fracture healing and would be very useful to replace the mechanical testing.
Bray, Joshua M.; Lauchnor, Ellen G.; Redden, George D.; ...
2016-12-21
Here, precipitation reactions in porous media influence transport properties of the environment and can control advective and dispersive transport. In subsurface environments, mixing of saline groundwater or injected solutions for remediation with fresh groundwater can induce supersaturation of constituents and drive precipitation reactions. Magnetic resonance imaging (MRI) and micro-computed tomography (µ-CT) were employed as complimentary techniques to evaluate advection, dispersion and formation of precipitate in a 3D porous media flow cell. Two parallel fluids were flowed concentrically through the porous media under two flow rate conditions with Na 2CO 3 and CaCl 2 in the inner and outer fluids, respectively.more » Upon mixing, calcium carbonate became supersaturated and formed a precipitate at the interface of the two fluids. Spatial maps of changing local velocity fields and dispersion in the flow cell were generated from MRI, while high resolution imaging of the precipitate formed in the porous media was achieved via µ-CT imaging. Formation of a precipitate layer minimized dispersive and advective transport between the two fluids and the shape of the precipitation was influenced by the flow rate condition.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bray, Joshua M.; Lauchnor, Ellen G.; Redden, George D.
Here, precipitation reactions in porous media influence transport properties of the environment and can control advective and dispersive transport. In subsurface environments, mixing of saline groundwater or injected solutions for remediation with fresh groundwater can induce supersaturation of constituents and drive precipitation reactions. Magnetic resonance imaging (MRI) and micro-computed tomography (µ-CT) were employed as complimentary techniques to evaluate advection, dispersion and formation of precipitate in a 3D porous media flow cell. Two parallel fluids were flowed concentrically through the porous media under two flow rate conditions with Na 2CO 3 and CaCl 2 in the inner and outer fluids, respectively.more » Upon mixing, calcium carbonate became supersaturated and formed a precipitate at the interface of the two fluids. Spatial maps of changing local velocity fields and dispersion in the flow cell were generated from MRI, while high resolution imaging of the precipitate formed in the porous media was achieved via µ-CT imaging. Formation of a precipitate layer minimized dispersive and advective transport between the two fluids and the shape of the precipitation was influenced by the flow rate condition.« less
Shaping Ability of Single-file Systems with Different Movements: A Micro-computed Tomographic Study.
Santa-Rosa, Joedy; de Sousa-Neto, Manoel Damião; Versiani, Marco Aurelio; Nevares, Giselle; Xavier, Felipe; Romeiro, Kaline; Cassimiro, Marcely; Leoni, Graziela Bianchi; de Menezes, Rebeca Ferraz; Albuquerque, Diana
2016-01-01
This study aimed to perform a rigorous sample standardization and also evaluate the preparation of mesiobuccal (MB) root canals of maxillary molars with severe curvatures using two single-file engine-driven systems (WaveOne with reciprocating motion and OneShape with rotary movement), using micro-computed tomography (micro-CT). Ten MB roots with single canals were included, uniformly distributed into two groups (n=5). The samples were prepared with a WaveOne or OneShape files. The shaping ability and amount of canal transportation were assessed by a comparison of the pre- and post-instrumentation micro-CT scans. The Kolmogorov-Smirnov and t-tests were used for statistical analysis. The level of significance was set at 0.05. Instrumentation of canals increased their surface area and volume. Canal transportation occurred in coronal, middle and apical thirds and no statistical difference was observed between the two systems (P>0.05). In apical third, significant differences were found between groups in canal roundness (in 3 mm level) and perimeter (in 3 and 4 mm levels) (P<0.05). The WaveOne and One Shape single-file systems were able to shape curved root canals, producing minor changes in the canal curvature.
ERIC Educational Resources Information Center
Weaver, Dave
Science interfacing packages (also known as microcomputer-based laboratories or probeware) generally consist of a set of programs on disks, a user's manual, and hardware which includes one or more sensory devices. Together with a microcomputer they combine to make a powerful data acquisition and analysis tool. Packages are available for accurately…
Taylor, Susan; Ringelberg, David B; Dontsova, Katerina; Daghlian, Charles P; Walsh, Marianne E; Walsh, Michael R
2013-11-01
Two compounds, 2,4-dinitroanisole (DNAN) and 3-nitro-1,2,4-triazol-5-one (NTO) are the main ingredients in a suite of explosive formulations that are being, or soon will be, fielded at military training ranges. We aim to understand the dissolution characteristics of DNAN and NTO and three insensitive muntions (IM) formulations that contain them. This information is needed to accurately predict the environmental fate of IM constituents, some of which may be toxic to people and the environment. We used Raman spectroscopy to identify the different constituents in the IM formulations and micro computed tomography to image their three-dimensional structure. These are the first three-dimensional images of detonated explosive particles. For multi-component explosives the solubility of the individual constituents and the fraction of each constituent wetted by water controls the dissolution. We found that the order of magnitude differences in solubility amongst the constituents of these IM formulations quickly produced hole-riddled particles when these were exposed to water. Micro-computed tomography showed that particles resulting from field detonations were fractured, producing conduits by which water could access the interior of the particle. We think that micro-computed tomography can also be used to determine the initial composition of IM particles and to track how their compositions change as the particles dissolve. This information is critical to quantifying dissolution and developing physically based dissolution models. Published by Elsevier Ltd.
Sensitivity and accuracy of hybrid fluorescence-mediated tomography in deep tissue regions.
Rosenhain, Stefanie; Al Rawashdeh, Wa'el; Kiessling, Fabian; Gremse, Felix
2017-09-01
Fluorescence-mediated tomography (FMT) enables noninvasive assessment of the three-dimensional distribution of near-infrared fluorescence in mice. The combination with micro-computed tomography (µCT) provides anatomical data, enabling improved fluorescence reconstruction and image analysis. The aim of our study was to assess sensitivity and accuracy of µCT-FMT under realistic in vivo conditions in deeply-seated regions. Accordingly, we acquired fluorescence reflectance images (FRI) and µCT-FMT scans of mice which were prepared with rectal insertions with different amounts of fluorescent dye. Default and high-sensitivity scans were acquired and background signal was analyzed for three FMT channels (670 nm, 745 nm, and 790 nm). Analysis was performed for the original and an improved FMT reconstruction using the µCT data. While FRI and the original FMT reconstruction could detect 100 pmol, the improved FMT reconstruction could detect 10 pmol and significantly improved signal localization. By using a finer sampling grid and increasing the exposure time, the sensitivity could be further improved to detect 0.5 pmol. Background signal was highest in the 670 nm channel and most prominent in the gastro-intestinal tract and in organs with high relative amounts of blood. In conclusion, we show that µCT-FMT allows sensitive and accurate assessment of fluorescence in deep tissue regions. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Spagnuolo, Gianrico; Ametrano, Gianluca; D'Antò, Vincenzo; Formisano, Anna; Simeone, Michele; Riccitiello, Francesco; Amato, Massimo; Rengo, Sandro
2012-01-01
Aim of the study was to determined by microcomputed tomography (µCT) the horizontal distance between the main (MB1) and the second mesiobuccal canal (MB2) orifices, the vertical distance between the MB1 and MB2 orifices planes, and the distance between the anatomic apex and major apical foramen (AF). Furthermore, we characterized the entire internal and external anatomy of the MB, distalbuccal (DB) and palatal (P) maxillary first molars roots. Twenty-two intact extracted first maxillary molars were scanned by X-ray computed transaxial µCT and then 2D and 3D images were processed and analyzed. The results showed that 77.27% of the mesiobuccal (MB) roots presented a second MB canal, and 29.41% of the MB2 were independent from the MB1 canals. In 15 teeth, there were three root canal orifices on the chamber floor, and 10 of these teeth presented MB2 canals. The mean vertical distance between the MB1 and MB2 planes was 1.68 ± 0.83 mm. Seven teeth had four orifices. The mean horizontal interorificial distance between the MB1 and MB2 orifices was 1.21 ± 0.5 mm. Accessory canals were observed in 33.33% of the roots, loops in 6.06%, while isthmuses were found in 15 of the 22 MB roots. Of the total roots, 74.24% presented one foramen, while all of the roots showed a major apical foramen that was not coincident with the anatomic apex. Our µCT analysis provided interesting features on the horizontal and vertical distance between the MB1 and MB2 orifices and on the distance of AF and anatomic apex. These results have an important clinical value because might support the endodontist in the recruitment, negotiation and obturation of maxillary first molar canal system.
Spagnuolo, Gianrico; Ametrano, Gianluca; D’Antò, Vincenzo; Formisano, Anna; Simeone, Michele; Riccitiello, Francesco; Amato, Massimo; Rengo, Sandro
2012-01-01
Objective: Aim of the study was to determined by microcomputed tomography (µCT) the horizontal distance between the main (MB1) and the second mesiobuccal canal (MB2) orifices, the vertical distance between the MB1 and MB2 orifices planes, and the distance between the anatomic apex and major apical foramen (AF). Furthermore, we characterized the entire internal and external anatomy of the MB, distalbuccal (DB) and palatal (P) maxillary first molars roots. Materials and Methods: Twenty-two intact extracted first maxillary molars were scanned by X-ray computed transaxial µCT and then 2D and 3D images were processed and analyzed. Results: The results showed that 77.27% of the mesiobuccal (MB) roots presented a second MB canal, and 29.41% of the MB2 were independent from the MB1 canals. In 15 teeth, there were three root canal orifices on the chamber floor, and 10 of these teeth presented MB2 canals. The mean vertical distance between the MB1 and MB2 planes was 1.68 ± 0.83 mm. Seven teeth had four orifices. The mean horizontal interorificial distance between the MB1 and MB2 orifices was 1.21 ± 0.5 mm. Accessory canals were observed in 33.33% of the roots, loops in 6.06%, while isthmuses were found in 15 of the 22 MB roots. Of the total roots, 74.24% presented one foramen, while all of the roots showed a major apical foramen that was not coincident with the anatomic apex. Conclusions: Our µCT analysis provided interesting features on the horizontal and vertical distance between the MB1 and MB2 orifices and on the distance of AF and anatomic apex. Clinical Relevance: These results have an important clinical value because might support the endodontist in the recruitment, negotiation and obturation of maxillary first molar canal system. PMID:22905069
Wang, Chun-Neng; Hsu, Hao-Chun; Wang, Cheng-Chun; Lee, Tzu-Kuei; Kuo, Yan-Fu
2015-01-01
The quantification of floral shape variations is difficult because flower structures are both diverse and complex. Traditionally, floral shape variations are quantified using the qualitative and linear measurements of two-dimensional (2D) images. The 2D images cannot adequately describe flower structures, and thus lead to unsatisfactory discrimination of the flower shape. This study aimed to acquire three-dimensional (3D) images by using microcomputed tomography (μCT) and to examine the floral shape variations by using geometric morphometrics (GM). To demonstrate the advantages of the 3D-μCT-GM approach, we applied the approach to a second-generation population of florist's gloxinia (Sinningia speciosa) crossed from parents of zygomorphic and actinomorphic flowers. The flowers in the population considerably vary in size and shape, thereby served as good materials to test the applicability of the proposed phenotyping approach. Procedures were developed to acquire 3D volumetric flower images using a μCT scanner, to segment the flower regions from the background, and to select homologous characteristic points (i.e., landmarks) from the flower images for the subsequent GM analysis. The procedures identified 95 landmarks for each flower and thus improved the capability of describing and illustrating the flower shapes, compared with typically lower number of landmarks in 2D analyses. The GM analysis demonstrated that flower opening and dorsoventral symmetry were the principal shape variations of the flowers. The degrees of flower opening and corolla asymmetry were then subsequently quantified directly from the 3D flower images. The 3D-μCT-GM approach revealed shape variations that could not be identified using typical 2D approaches and accurately quantified the flower traits that presented a challenge in 2D images. The approach opens new avenues to investigate floral shape variations.
Kim, In Sook; Lee, Eui Nam; Cho, Tae Hyung; Song, Yun Mi; Hwang, Soon Jung; Oh, Ji Hye; Park, Eun Kyung; Koo, Tai Young; Seo, Young-Kwon
2011-02-01
Nonglycosylated recombinant human bone morphogenetic protein (rhBMP)-2 prepared in Escherichia coli (E. coli rhBMP-2) has recently been considered as an alternative to mammalian cell rhBMP-2. However, its clinical use is still limited owing to lack of evidence for osteogenic activity comparable with that of mammalian cell rhBMP-2 via microcomputed tomography-based analysis. Therefore, this study aimed to evaluate the ability of E. coli rhBMP-2 in absorbable collagen sponge to form ectopic and orthotopic bone and to compare it to that of mammalian rhBMP-2. In vitro investigation was performed to study osteoblast differentiation of human mesenchymal stromal cells. Both types of rhBMP-2 enhanced proliferation, alkaline phosphatase activity, and matrix mineralization of human mesenchymal stromal cells at similar levels. Similar tendencies were observed in microcomputed tomography analysis, which determined bone volume, fractional bone volume, trabecular thickness, trabecular separation, bone mineral density, and other characteristics. Histology from an in vivo osteoinductivity test and from a rat calvarial defect model demonstrated a dose-dependent increase in local bone formation. The E. coli rhBMP-2 group (5 μg) not only induced complete regeneration of an 8-mm critical-sized defect at 4 weeks, but also led to new bone with the same bone mineral density as normal bone at 8 weeks, with the same efficiency as that of mammalian cell rhBMP-2 (5 μg). These uniformly favorable results provide evidence that the osteogenic activity of E. coli rhBMP-2 is not inferior to that of mammalian cell rhBMP-2 despite its low solubility and lack of gylcosylation. These results suggest that the application of E. coli rhBMP-2 in absorbable collagen sponge may be a promising equivalent to mammalian cell rhBMP-2 in bone tissue engineering.
Computer Series, 67: Bits and Pieces, 27.
ERIC Educational Resources Information Center
Moore, John W., Ed.
1986-01-01
Discusses a computer interfacing course using Commodore 64 microcomputers; a computer program for radioactive equilibrium; analysis of near infrared spectrum of hydrochloric acid molecules using Apple II microcomputers; microcomputer approach to conductivity titrations; balancing equations with Commodore 64's; formulation of mathematical…
Jee, Jeong-Hyun; Lee, Wan; Lee, Byung Do
2010-08-01
Many dental patients take bisphosphonates to reduce the risk of hip and vertebral fractures. In vivo micro-computed tomography (micro-CT) was used to examine the longitudinal inhibitory effect of alendronate on the healing of extraction sockets in ovariectomized rats. Twenty 5-week-old Sprague-Dawley rats were assigned randomly to 1 of 3 groups: sham-operated (n = 5), and 2 ovariectomized (OVX) groups: saline treated (0.1 mL/100 g/d, n = 7) and alendronate treated (1 mg/kg/d, n = 8). Before micro-CT scanning, the left maxillary first molars of the rats were extracted. In vivo micro-CT (spatial resolution 50 x 50 mum) of the jaw was performed at baseline and at 2-week intervals for 6 weeks. Alveolar-bone radiographic densities and dimensions were analyzed with repeated measures analysis of variance. The bony healing patterns of the extraction sockets were also evaluated in each group. The radiographic socket densities of the sham-treated and OVX-alendronate groups significantly increased during the first 4 weeks after extraction (P < .05). At 2 weeks, the radiographic densities of the sockets in the OVX-saline group increased, but the increase was significantly lower than for the other groups at 4 weeks (P < .05). Newly formed bone was identified in the extraction sockets in all groups 2 to 6 weeks after extraction. There was a significant loss of alveolar ridge height at the second week postextraction compared with baseline, and at the fourth week compared with the second week (P < .05) except in the alendronate group. Alendronate appears to promote the healing of extraction sockets in estrogen-deficient rats and helps resist the loss of alveolar bone adjacent to extraction sockets. Copyright 2010 Mosby, Inc. All rights reserved.
Microcomputed tomography and shock microdeformation studies on shatter cones
NASA Astrophysics Data System (ADS)
Zaag, Patrice Tristan; Reimold, Wolf Uwe; Hipsley, Christy Anna
2016-08-01
One of the aspects of impact cratering that are still not fully understood is the formation of shatter cones and related fracturing phenomena. Yet, shatter cones have been applied as an impact-diagnostic criterion for decades without the role of shock waves and target rock defects in their formation having been elucidated ever. We have tested the application of the nondestructive microcomputed tomography (μCT) method to visualize the interior of shatter cones in order to possibly resolve links between fracture patterns and shatter cone surface features (striations and intervening "valleys"). Shatter-coned samples from different impact sites and in different lithologies were investigated for their μCT suitability, with a shatter cone in sandstone from the Serra da Cangalha impact structure (Brazil) remaining as the most promising candidate because of the fracture resolution achieved. To validate the obtained CT data, the scanned specimen was cut into three orthogonal sets of thin sections. Scans with 13 μm resolution were obtained. μCT scans and microscopic analysis unraveled an orientation of subplanar fractures and related fluid inclusion trails, and planar fracture (PF) orientations in the interior of shatter cones. Planar deformation features (PDF) were observed predominantly near the shatter cone surface. Previously undescribed varieties of feather features (FF), in the form of lamellae emanating from curviplanar and curved fractures, as well as an "arrowhead"-like FF development with microlamellae originating from both sides of a PF, were observed. The timing of shatter cone formation was investigated by establishing temporal relations to the generation of various shock microscopic effects. Shatter cones are, thus, generated post- or syn-formation of PF, FF, subplanar fractures, and PDF. The earliest possible time for shatter cone formation is during the late stage of the compressional phase, that is, shock wave passage, of an impact event.
Optimizing a micro-computed tomography-based surrogate measurement of bone-implant contact.
Meagher, Matthew J; Parwani, Rachna N; Virdi, Amarjit S; Sumner, Dale R
2018-03-01
Histology and backscatter scanning electron microscopy (bSEM) are the current gold standard methods for quantifying bone-implant contact (BIC), but are inherently destructive. Microcomputed tomography (μCT) is a non-destructive alternative, but attempts to validate μCT-based assessment of BIC in animal models have produced conflicting results. We previously showed in a rat model using a 1.5 mm diameter titanium implant that the extent of the metal-induced artefact precluded accurate measurement of bone sufficiently close to the interface to assess BIC. Recently introduced commercial laboratory μCT scanners have smaller voxels and improved imaging capabilities, possibly overcoming this limitation. The goals of the present study were to establish an approach for optimizing μCT imaging parameters and to validate μCT-based assessment of BIC. In an empirical parametric study using a 1.5 mm diameter titanium implant, we determined 90 kVp, 88 µA, 1.5 μm isotropic voxel size, 1600 projections/180°, and 750 ms integration time to be optimal. Using specimens from an in vivo rat experiment, we found significant correlations between bSEM and μCT for BIC with the manufacturer's automated analysis routine (r = 0.716, p = 0.003) or a line-intercept method (r = 0.797, p = 0.010). Thus, this newer generation scanner's improved imaging capability reduced the extent of the metal-induced artefact zone enough to permit assessment of BIC. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:979-986, 2018. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Bone regeneration by means of a three-dimensional printed scaffold in a rat cranial defect.
Kwon, Doo Yeon; Park, Ji Hoon; Jang, So Hee; Park, Joon Yeong; Jang, Ju Woong; Min, Byoung Hyun; Kim, Wan-Doo; Lee, Hai Bang; Lee, Junhee; Kim, Moon Suk
2018-02-01
Recently, computer-designed three-dimensional (3D) printing techniques have emerged as an active research area with almost unlimited possibilities. In this study, we used a computer-designed 3D scaffold to drive new bone formation in a bone defect. Poly-L-lactide (PLLA) and bioactive β-tricalcium phosphate (TCP) were simply mixed to prepare ink. PLLA + TCP showed good printability from the micronozzle and solidification within few seconds, indicating that it was indeed printable ink for layer-by-layer printing. In the images, TCP on the surface of (and/or inside) PLLA in the printed PLLA + TCP scaffold looked dispersed. MG-63 cells (human osteoblastoma) adhered to and proliferated well on the printed PLLA + TCP scaffold. To assess new bone formation in vivo, the printed PLLA + TCP scaffold was implanted into a full-thickness cranial bone defect in rats. The new bone formation was monitored by microcomputed tomography and histological analysis of the in vivo PLLA + TCP scaffold with or without MG-63 cells. The bone defect was gradually spontaneously replaced with new bone tissues when we used both bioactive TCP and MG-63 cells in the PLLA scaffold. Bone formation driven by the PLLA + TCP30 scaffold with MG-63 cells was significantly greater than that in other experimental groups. Furthermore, the PLLA + TCP scaffold gradually degraded and matched well the extent of the gradual new bone formation on microcomputed tomography. In conclusion, the printed PLLA + TCP scaffold effectively supports new bone formation in a cranial bone defect. Copyright © 2017 John Wiley & Sons, Ltd.
NASA Astrophysics Data System (ADS)
Luan, Hui-Qin; Sun, Lian-Wen; Huang, Yun-Fei; Wu, Xin-tong; Niu, Haijun; Liu, Hong; Fan, Yu-Bo
2015-07-01
Space flight has been shown to induce bone loss and muscle atrophy, which could initiate the degeneration of articular cartilage. Countermeasures to prevent bone loss and muscle atrophy have been explored, but few spaceflight or ground-based studies have focused on the effects on cartilage degeneration. In this study, we investigated the effects of exercise on articular cartilage deterioration in tail-suspended rats. Thirty-two female Sprague-Dawley rats were randomly divided into four groups (n = 8 in each): tail suspension (TS), tail suspension plus passive motion (TSP), tail suspension plus active exercise (TSA), and control (CON) groups. In the TS, TSP, and TSA groups, the rat hindlimbs were unloaded for 21 days by tail suspension. Next, the cartilage thickness and volume, and the attenuation coefficient of the distal femur were evaluated by micro-computed tomography (μCT). Histological analysis was used to assess the surface integrity of the cartilage, cartilage thickness, and chondrocytes. The results showed that: (1) the cartilage thickness on the distal femur was significantly lower in the TS and TSP groups compared with the CON and TSA groups; (2) the cartilage volume in the TS group was significantly lower compared with the CON, TSA, and TSP groups; and (3) histomorphology showed that the chondrocytes formed clusters where the degree of matrix staining was lower in the TS and TSP groups. There were no significant differences between any of these parameters in the CON and TSA groups. The cartilage thickness measurements obtained by μCT and histomorphology correlated well. In general, tail suspension could induce articular cartilage degeneration, but active exercise was effective in preventing this degeneration in tail-suspended rats.
Sawicka, Monika; Bedini, Rossella; Wierzbicki, Piotr M; Pameijer, Cornelis H
2014-01-01
Root resorption is an undesirable but very frequently occurring sequel of orthodontic treatment. The aim of this study was to compare root resorption caused by either continuous (CF) or interrupted (IF) orthodontic force. The study was performed on human subjects on 30 first upper and lower premolars scheduled for extraction for orthodontic reasons. During four weeks before extraction 12 teeth were subjected to either CF or IF. The force was generated by a segmental titanium-molybdenum alloy cantilever spring that was activated in buccal direction. Initially a force of 60 CentiNewton was used in both CF and IF groups, the force in the former, however, was reactivated every week for 4 weeks. There was no reactivation of force in the IF group after initial application. A morphometric analysis of root resorption was performed by microcomputed tomography and the extent of tooth movement was measured on stone casts. Furthermore, a Tartarate-Resistant Acidic Phosphatase activity (TRAP), the marker enzyme of osteoclasts and cementoclasts, was determined by histochemical method. The Mann-Whitney U test was used to compare the difference in measured parameters between treatment and control tooth groups. The number of resorption craters was significantly higher and their average volume almost twice as large in the CF compared to the IF group (p < 0.05). However, the distance of tooth displacement was similar for both groups. Cementoclasts were detected with the TRAP technique on the surface of two teeth only; both were subjected to continuous force. The use of IF leads to less destruction of root structure as opposed to continuous force while the same tooth movement was achieved.
Marceliano-Alves, Marília; Alves, Flávio Rodrigues Ferreira; Mendes, Daniel de Melo; Provenzano, José Claudio
2016-02-01
A thorough knowledge of root canal anatomy is critical for successful root canal treatments. This study evaluated the internal anatomy of the palatal roots of maxillary first molars with micro-computed tomography (microCT). The palatal roots of extracted maxillary first molars (n = 169) were scanned with microCT to determine several anatomic parameters, including main canal classification, lateral canal occurrence and location, degree of curvature, main foramen position, apical constriction presence, diameters 1 and 2 mm from the apex and 1 mm from the foramen, minor dentin thickness in those regions, canal volume, surface area, and convexity. All canals were classified as Vertucci type I. The cross sections were oval in 61% of the canals. Lateral canals were found in 25% of the samples. The main foramen did not coincide with the root apex in 95% of the cases. Only 8% of the canals were classified as straight. Apical constriction was identified in 38% of the roots. The minor and major canal diameters and minor dentin thickness were decreased near the apex. The minor dentin thickness 1 mm from the foramen was 0.82 mm. The palatal canals exhibited a volume of 6.91 mm(3) and surface area of 55.31 mm(2) and were rod-shaped. The root canals of the palatal roots were classified as type I. However, some factors need to be considered during the treatment of these roots, including the frequent ocurrence of moderate/severe curvatures, oval-shaped cross-sections, and lateral canals, noncoincidence of the apical foramen with the root apex, and absence of apical constriction in most cases. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gerhard, M.A.; Sommer, S.C.
1995-04-01
AUTOCASK (AUTOmatic Generation of 3-D CASK models) is a microcomputer-based system of computer programs and databases developed at the Lawrence Livermore National Laboratory (LLNL) for the structural analysis of shipping casks for radioactive material. Model specification is performed on the microcomputer, and the analyses are performed on an engineering workstation or mainframe computer. AUTOCASK is based on 80386/80486 compatible microcomputers. The system is composed of a series of menus, input programs, display programs, a mesh generation program, and archive programs. All data is entered through fill-in-the-blank input screens that contain descriptive data requests.
Novel application and serial evaluation of tissue-engineered portal vein grafts in a murine model.
Maxfield, Mark W; Stacy, Mitchel R; Kurobe, Hirotsugu; Tara, Shuhei; Yi, Tai; Cleary, Muriel A; Zhuang, Zhen W; Rodriguez-Davalos, Manuel I; Emre, Sukru H; Iwakiri, Yasuko; Shinoka, Toshiharu; Breuer, Christopher K
2017-12-01
Surgical management of pediatric extrahepatic portal vein obstruction requires meso-Rex bypass using autologous or synthetic grafts. Tissue-engineered vascular grafts (TEVGs) provide an alternative, but no validated animal models using portal TEVGs exist. Herein, we preclinically assess TEVGs as portal vein bypass grafts. TEVGs were implanted as portal vein interposition conduits in SCID-beige mice, monitored by ultrasound and micro-computed tomography, and histologically assessed postmortem at 12 months. TEVGs remained patent for 12 months. Histologic analysis demonstrated formation of neovessels that resembled native portal veins, with similar content of smooth muscle cells, collagen type III and elastin. TEVGs are feasible portal vein conduits in a murine model. Further preclinical evaluation of TEVGs may facilitate pediatric clinical translation.
Yunos, Mohd Amirul Syafiq Mohd; Hussain, Siti Aslina; Yusoff, Hamdan Mohamed; Abdullah, Jaafar
2014-09-01
Radioactive particle tracking (RPT) has emerged as a promising and versatile technique that can provide rich information about a variety of multiphase flow systems. However, RPT is not an off-the-shelf technique, and thus, users must customize RPT for their applications. This paper presents a simple procedure for preparing radioactive tracer particles created via irradiation with neutrons from the TRIGA Mark II research reactor. The present study focuses on the performance evaluation of encapsulated gold and scandium particles for applications as individual radioactive tracer particles using qualitative and quantitative neutron activation analysis (NAA) and an X-ray microcomputed tomography (X-ray Micro-CT) scanner installed at the Malaysian Nuclear Agency. Copyright © 2014 Elsevier Ltd. All rights reserved.
Marinozzi, Franco; Marinozzi, Andrea; Bini, Fabiano; Zuppante, Francesca; Pecci, Raffaella; Bedini, Rossella
2012-01-01
Morphometric and architectural bone parameters change in diseases such as osteoarthritis and osteoporosis. The mechanical strength of bone is primarily influenced by bone quantity and quality. Bone quality is defined by parameters such as trabecular thickness, trabecular separation, trabecular density and degree of anisotropy that describe the micro-architectural structure of bone. Recently, many studies have validated microtomography as a valuable investigative technique to assess bone morphometry, thanks to micro-CT non-destructive, non-invasive and reliability features, in comparison to traditional techniques such as histology. The aim of this study is the analysis by micro-computed tomography of six specimens, extracted from patients affected by osteoarthritis and osteoporosis, in order to observe the tridimensional structure and calculate several morphometric parameters.
Microcomputers: Software Evaluation. Evaluation Guides. Guide Number 17.
ERIC Educational Resources Information Center
Gray, Peter J.
This guide discusses three critical steps in selecting microcomputer software and hardware: setting the context, software evaluation, and managing microcomputer use. Specific topics addressed include: (1) conducting an informal task analysis to determine how the potential user's time is spent; (2) identifying tasks amenable to computerization and…
Microcomputer Applications for Teaching Microeconomic Concepts: Some Old and New Approaches.
ERIC Educational Resources Information Center
Smith, L. Murphy; Smith, L. C., Jr.
1989-01-01
Presents microcomputer programs and programing techniques and demonstrates how these programs can be used by teachers to explain economics concepts and to help students make judgments. Each microcomputer application is supplemented by traditional graphic and mathematical analysis. Discusses applications dealing with supply, demand, elasticity,…
Contrast Agents for Micro-Computed Tomography of Microdamage in Bone
2011-01-01
solution from DI water (or PBS). For the second model, a 5 mm cube of cortical bone tissue was embedded in polymethylmethacrylate and sectioned...radiography1 and as a radiopacifer in polymethylmethacrylate bone cement.2 Current commercial products for either application use microscale BaSO4 particles... polymethylmethacrylate bone cement (Lewis, 1997). The objective of this study was to non-destructively and three-dimensionally image microdamage
Contrast Agents for Micro-Computed Tomography of Microdamage in Bone
2009-01-01
carboxylate (reported in January 2009), phosphonate and bisphosphonate groups (Fig. 2). The presence of functional groups was verified by FT- IR (Fig. 3...carboxylic acid, (b) phosphonate or (c) bisphosphonate groups for calcium binding damaged tissue. (a) (b) (c) Fig. 3. FT- IR spectra for Au NPs...functional group. Quantitative measurements of the binding affinity were performed by adding hydroxyapatite (HA) crystals to functionalized Au NP solutions in
Baek, Young-Jae; Kim, Jung-Han; Song, Jae-Min; Yoon, Sang-Yong; Kim, Hong-Sung; Shin, Sang-Hun
2016-12-01
In guided bone regeneration (GBR) technique, many materials have been used for improving biological effectiveness by adding on membranes. The new membrane which was constructed with chitin-fibroin-hydroxyapatite (CNF/HAP) was compared with a collagen membrane (Bio-Gide®) by means of micro-computed tomography. Fifty-four rats were used in this study. A critical-sized (8 mm) bony defect was created in the calvaria with a trephine bur. The CNF/HAP membrane was prepared by thermally induced phase separation. In the experimental group ( n = 18), the CNF/HAP membrane was used to cover the bony defect, and in the control group ( n = 18), a resorbable collagen membrane (Bio-Gide®) was used. In the negative control group ( n = 18), no membrane was used. In each group, six animals were euthanized at 2, 4, and 8 weeks after surgery. The specimens were analyzed using micro-CT. Bone volume (BV) and bone mineral density (BMD) of the new bone showed significant difference between the negative control group and membrane groups ( P < 0.05). However, between two membranes, the difference was not significant. The CNF/HAP membrane has significant effect on the new bone formation and has the potential to be applied for guided bone regeneration.
Micro-computed tomography visualization of the vestigial alimentary canal in adult oestrid flies.
Martín-Vega, D; Garbout, A; Ahmed, F; Ferrer, L M; Lucientes, J; Colwell, D D; Hall, M J R
2018-02-16
Oestrid flies (Diptera: Oestridae) do not feed during the adult stage as they acquire all necessary nutrients during the parasitic larval stage. The adult mouthparts and digestive tract are therefore frequently vestigial; however, morphological data on the alimentary canal in adult oestrid flies are scarce and a proper visualization of this organ system within the adult body is lacking. The present work visualizes the morphology of the alimentary canal in adults of two oestrid species, Oestrus ovis L. and Hypoderma lineatum (de Villiers), with the use of non-invasive micro-computed tomography (micro-CT) and compares it with the highly developed alimentary canal of the blow fly Calliphora vicina Robineau-Desvoidy (Diptera: Calliphoridae). Both O. ovis and H. lineatum adults showed significant reductions of the cardia and the diameter of the digestive tract, an absence of the helicoidal portion of the midgut typical of other cyclorrhaphous flies, and a lack of crop and salivary glands. Given the current interest in the alimentary canal in adult dipterans in biomedical and developmental biology studies, further understanding of the morphology and development of this organ system in adult oestrids may provide valuable new insights in several areas of research. © 2018 The Royal Entomological Society.
Patterson, Braydon M; Dalci, Oyku; Papadopoulou, Alexandra K; Madukuri, Suman; Mahon, Jonathan; Petocz, Peter; Spahr, Axel; Darendeliler, M Ali
2017-01-01
The purpose of this study was to investigate the effect of piezocision on orthodontically induced inflammatory root resorption. Fourteen patients were included in this split-mouth study; 1 side was assigned to piezocision, and the other side served as the control. Vertical corticotomy cuts of 4 to 5 mm in length were performed on either side of each piezocision premolar, and 150-g buccal tipping forces were applied to the premolars. After 4 weeks, the maxillary first premolars were extracted and scanned with microcomputed tomography. There was a significantly greater total amount of root resorption seen on the piezocision sides when compared with the control sides (P = 0.029). The piezocision procedure resulted in a 44% average increase in root resorption. In 5 patients, there was noticeable piezocision-related iatrogenic root damage. When that was combined with the orthodontic root resorption found on the piezocision-treated teeth, there was a statistically significant 110% average increase in volumetric root loss when compared with the control side (P = 0.005). The piezocision procedure that initiates the regional acceleratory phenomenon may increase the iatrogenic root resorption when used in conjunction with orthodontic forces. Piezocision applied close to the roots may cause iatrogenic damage to the neighboring roots and should be used carefully. Copyright © 2017.
Brereton, Nicholas James Beresford; Ahmed, Farah; Sykes, Daniel; Ray, Michael Jason; Shield, Ian; Karp, Angela; Murphy, Richard James
2015-03-11
Variation in the reaction wood (RW) response has been shown to be a principle component driving differences in lignocellulosic sugar yield from the bioenergy crop willow. The phenotypic cause(s) behind these differences in sugar yield, beyond their common elicitor, however, remain unclear. Here we use X-ray micro-computed tomography (μCT) to investigate RW-associated alterations in secondary xylem tissue patterning in three dimensions (3D). Major architectural alterations were successfully quantified in 3D and attributed to RW induction. Whilst the frequency of vessels was reduced in tension wood tissue (TW), the total vessel volume was significantly increased. Interestingly, a delay in programmed-cell-death (PCD) associated with TW was also clearly observed and readily quantified by μCT. The surprising degree to which the volume of vessels was increased illustrates the substantial xylem tissue remodelling involved in reaction wood formation. The remodelling suggests an important physiological compromise between structural and hydraulic architecture necessary for extensive alteration of biomass and helps to demonstrate the power of improving our perspective of cell and tissue architecture. The precise observation of xylem tissue development and quantification of the extent of delay in PCD provides a valuable and exciting insight into this bioenergy crop trait.
Carlisle, Patricia L; Guda, Teja; Silliman, David T; Lien, Wen; Hale, Robert G; Brown Baer, Pamela R
2016-02-01
To validate a critical-size mandibular bone defect model in miniature pigs. Bilateral notch defects were produced in the mandible of dentally mature miniature pigs. The right mandibular defect remained untreated while the left defect received an autograft. Bone healing was evaluated by computed tomography (CT) at 4 and 16 weeks, and by micro-CT and non-decalcified histology at 16 weeks. In both the untreated and autograft treated groups, mineralized tissue volume was reduced significantly at 4 weeks post-surgery, but was comparable to the pre-surgery levels after 16 weeks. After 16 weeks, CT analysis indicated that significantly greater bone was regenerated in the autograft treated defect than in the untreated defect (P=0.013). Regardless of the treatment, the cortical bone was superior to the defect remodeled over 16 weeks to compensate for the notch defect. The presence of considerable bone healing in both treated and untreated groups suggests that this model is inadequate as a critical-size defect. Despite healing and adaptation, the original bone geometry and quality of the pre-injured mandible was not obtained. On the other hand, this model is justified for evaluating accelerated healing and mitigating the bone remodeling response, which are both important considerations for dental implant restorations.
Emam, Hany; Beheiri, Galal; Elsalanty, Mohammed; Sharawy, Mohamed
2011-01-01
Anorganic bovine hydroxyapatite matrix (ABM), when coupled with synthetic cell-binding peptide (P15), mimics the cell-binding region of type 1 collagen and is commercially available suspended in a sodium hyaluronate carrier. The aim of the present study, therefore, was to test the efficacy of ABM/P-15 Putty (DENTSPLY Friadent CeraMed) as a sole graft material for sinus augmentation in patients with severely resorbed posterior maxillae. Sinus augmentation was performed in 10 patients using ABM/P-15 Putty and two provisional dental implants (3.0 mm in diameter). The graft and implants were placed simultaneously with the aid of a surgical stent. After 8 or 16 weeks, the implants were removed using a 4.25-mm trephine bur; this was followed by immediate placement of wider-diameter (5.5-mm) implants. All 20 implants were scanned by microcomputed tomography to determine bone mineral density (BMD), percent bone volume (PBV), and percent bone contact (PBC). There was a significant increase in the BMD of bone around the implants at 8 weeks and 16 weeks compared to native residual (control) bone. There was no significant difference in PBV or PBC between 8 weeks and 16 weeks. The average increase in bone height at 16 weeks was 9.63 ± 1 mm. Microcomputed tomographic images and histologic sections showed dense graft particles surrounded by vital trabecular bone. BMD increases as early as 8 weeks and does not show an additional increase after 16 weeks. PepGen P-15 Putty was found to be a promising osteoconductive graft for sinus augmentation, supporting immediate placement of implants.
Hwang, Young-Hye; Bae, Kwang-Shik; Baek, Seung-Ho; Kum, Kee-Yeon; Lee, WooCheol; Shon, Won-Jun; Chang, Seok Woo
2014-08-01
This study used micro-computed tomographic imaging to compare the shaping ability of Mtwo (VDW, Munich, Germany), a conventional nickel-titanium file system, and Reciproc (VDW), a reciprocating file system morphologically similar to Mtwo. Root canal shaping was performed on the mesiobuccal and distobuccal canals of extracted maxillary molars. In the RR group (n = 15), Reciproc was used in a reciprocating motion (150° counterclockwise/30° clockwise, 300 rpm); in the MR group, Mtwo was used in a reciprocating motion (150° clockwise/30° counterclockwise, 300 rpm); and in the MC group, Mtwo was used in a continuous rotating motion (300 rpm). Micro-computed tomographic images taken before and after canal shaping were used to analyze canal volume change and the degree of transportation at the cervical, middle, and apical levels. The time required for canal shaping was recorded. Afterward, each file was analyzed using scanning electron microscopy. No statistically significant differences were found among the 3 groups in the time for canal shaping or canal volume change (P > .05). Transportation values of the RR and MR groups were not significantly different at any level. However, the transportation value of the MC group was significantly higher than both the RR and MR groups at the cervical and apical levels (P < .05). In the scanning electron microscopic analysis, file deformation was observed for 1 file in group RR (1/15), 3 files in group MR (3/15), and 5 files in group MC (5/15). In terms of shaping ability, Mtwo used in a reciprocating motion was not significantly different from the Reciproc system. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
NASA Technical Reports Server (NTRS)
Erickson, W. K.; Hofman, L. B.; Donovan, W. E.
1984-01-01
Difficulties regarding the digital image analysis of remotely sensed imagery can arise in connection with the extensive calculations required. In the past, an expensive large to medium mainframe computer system was needed for performing these calculations. For image-processing applications smaller minicomputer-based systems are now used by many organizations. The costs for such systems are still in the range from $100K to $300K. Recently, as a result of new developments, the use of low-cost microcomputers for image processing and display systems appeared to have become feasible. These developments are related to the advent of the 16-bit microprocessor and the concept of the microcomputer workstation. Earlier 8-bit microcomputer-based image processing systems are briefly examined, and a computer workstation architecture is discussed. Attention is given to a microcomputer workstation developed by Stanford University, and the design and implementation of a workstation network.
NASA Astrophysics Data System (ADS)
Laaß, Michael; Schillinger, Burkhard; Werneburg, Ingmar
As having evolved on the stem line of mammals, the taxonomy and phylogeny of therapsids (Synapsida) are of special interest with respect to early mammalian evolution. Due to the fact that in most cases soft tissue of fossil vertebrates is not preserved, species can only be distinguished by diagnosis of morphological features of the skeleton. Moreover, investigations of vertebrate fossils are often obstructed, because internal cranial anatomy is usually hidden and parts of the fossils may be embedded in stone matrix. As a consequence, most species of non-mammalian synapsids were only defined on the basis of external skeletal features. Our investigations on Diictodon skulls (Therapsida, Anomodontia) show that non-destructive methods are very useful to clearly distinguish fossil species. We, therefore, propose using modern non-destructive techniques such as neutron tomography, synchrotron tomography, and micro-computed tomography (μCT) as standard tools for the investigation and virtual reconstruction of fossils and to include features of the internal cranial anatomy into morphological descriptions and phylogenetic analyses of fossil vertebrates.
The Impact of Microcomputer-Based Science Labs on Children's Graphing Skills.
ERIC Educational Resources Information Center
Mokros, Janice R.
Microcomputer-based laboratories (MBL), the use of microcomputers for student-directed data acquisition and analysis, represents a promising new development in science laboratory instruction. This descriptive study determined the impact of MBLs on middle school students' understanding of graphs of distance and velocity. The study was based on the…
Microcomputers: Communication Software. Evaluation Guides. Guide Number 13.
ERIC Educational Resources Information Center
Gray, Peter J.
This guide discusses four types of microcomputer-based communication programs that could prove useful to evaluators: (1) the direct communication of information generated by one computer to another computer; (2) using the microcomputer as a terminal to a mainframe computer to input, direct the analysis of, and/or output data using a statistical…
NASA Astrophysics Data System (ADS)
Sinescu, Cosmin; Negrutiu, Meda Lavinia; Ionita, Ciprian; Marsavina, Liviu; Negru, Radu; Topala, Florin; Petrescu, Emanuela; Rominu, Roxana; Fabriky, Mihai; Bradu, Adrian; Rominu, Mihai; Podoleanu, Adrian Gh.
2011-10-01
Imagistic investigation of the metal-ceramic crowns and fixed partial prostheses represent a very important issue in nowadays dentistry. At this time, in dental office, it is difficult or even impossible to evaluate a metal ceramic crown or bridge before setting it in the oral cavity. The possibilities of ceramic fractures are due to small fracture lines or material defects inside the esthetic layers. Material and methods: In this study 25 metal ceramic crowns and fixed partial prostheses were investigated by radiographic method (Rx), micro computer tomography (MicroCT) and optical coherence tomography (OCT) working in Time Domain, at 1300 nm. The OCT system contains two interferometers and one scanner. For each incident analysis a stuck made of 100 slices was obtain. These slices were used in order to obtain a 3D model of the ceramic interface. After detecting the presence and the positions of the ceramic defects the numerical simulation method was used to estimate the biomechanical effect of the masticatory forces on fractures propagations in ceramic materials. Results: For all the dental ceramic defects numerical simulation analysis was performed. The simulation of crack propagation shows that the crack could initiate from the upper, lower or both parts of the defect and propagates through the ceramic material where tensile stress field is present. RX and MicroCT are very powerful instruments that provide a good characterization of the dental construct. It is important to observe the reflections due to the metal infrastructure that could affect the evaluation of the metal ceramic crowns and bridges. The OCT investigations could complete the imagistic evaluation of the dental construct by offering important information when it is need it.
Using Microcomputers for Assessment and Error Analysis. Monograph #23.
ERIC Educational Resources Information Center
Hasselbring, Ted S.; And Others
This monograph provides an overview of computer-based assessment and error analysis in the instruction of elementary students with complex medical, learning, and/or behavioral problems. Information on generating and scoring tests using the microcomputer is offered, as are ideas for using computers in the analysis of mathematical strategies and…
Biocompatibility of PCL/PLGA-BCP porous scaffold for bone tissue engineering applications.
Thi Hiep, Nguyen; Chan Khon, Huynh; Dai Hai, Nguyen; Byong-Taek, Lee; Van Toi, Vo; Thanh Hung, Le
2017-06-01
In this study, biomimic porous polycaprolactone/poly (lactide-co-glycolide) loading biphasic tricalcium phosphate (PCL/PLGA-BCP) scaffolds were fabricated successfully by solvent evaporation method. The distribution of biphasic tricalcium phosphate (BCP) in polycaprolactone/poly (lactide-co-glycolide) (PCL/PLGA) scaffold was confirmed by micro-computed tomography (micro-CT) scanning, scanning electron microscope (SEM) observation and Energy-dispersive X-ray Spectroscopy (EDS) analysis. The hydrophilicity of the scaffolds was confirmed by contact angle measurement. In in vitro experiments, proliferation of human bone marrow mesenchymal stem cell (hBMSCs) and its osteoblastic differentiation on scaffold were assessed for 1, 2 and 3 weeks using 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assay, fluorescence observation, hematoxylin & eosin (H&E) staining and real-time polymerase chain reaction (RT-PCR). In in vivo experiments, ossification was observed using micro-CT analysis and histological staining.
Lu, Steven; Lam, Johnny; Trachtenberg, Jordan E; Lee, Esther J; Seyednejad, Hajar; van den Beucken, Jeroen J J P; Tabata, Yasuhiko; Kasper, F Kurtis; Scott, David W; Wong, Mark E; Jansen, John A; Mikos, Antonios G
2015-12-01
The present work investigated correlations between cartilage and subchondral bone repair, facilitated by a growth factor-delivering scaffold, in a rabbit osteochondral defect model. Histological scoring indices and microcomputed tomography morphological parameters were used to evaluate cartilage and bone repair, respectively, at 6 and 12 weeks. Correlation analysis revealed significant associations between specific cartilage indices and subchondral bone parameters that varied with location in the defect (cortical vs. trabecular region), time point (6 vs. 12 weeks), and experimental group (insulin-like growth factor-1 only, bone morphogenetic protein-2 only, or both growth factors). In particular, significant correlations consistently existed between cartilage surface regularity and bone quantity parameters. Overall, correlation analysis between cartilage and bone repair provided a fuller understanding of osteochondral repair and can help drive informed studies for future osteochondral regeneration strategies.
Microcomputer Applications in Interaction Analysis.
ERIC Educational Resources Information Center
Wadham, Rex A.
The Timed Interval Categorical Observation Recorder (TICOR), a portable, battery powered microcomputer designed to automate the collection of sequential and simultaneous behavioral observations and their associated durations, was developed to overcome problems in gathering subtle interaction analysis data characterized by sequential flow of…
A microcomputer-based whole-body counter for personnel routine monitoring.
Chou, H P; Tsai, T M; Lan, C Y
1993-05-01
The paper describes a cost-effective NaI(Tl) whole-body counter developed for routine examinations of worker intakes at an isotope production facility. Signal processing, data analysis and system operation are microcomputer-controlled for minimum human interactions. The pulse height analyzer is developed as an microcomputer add-on card for easy manipulation. The scheme for radionuclide analysis is aimed for fast running according to a knowledge base established from background samples and phantom experiments in conjunction with a multivariate regression analysis. Long-term stability and calibration with standards and in vivo measurements are reported.
Shape and Size of Microfine Aggregates: X-ray Microcomputed Tomgraphy vs. Laser Diffraction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Erdogan,S.; Garboczi, E.; Fowler, D.
Microfine rock aggregates, formed naturally or in a crushing process, pass a No. 200 ASTM sieve, so have at least two orthogonal principal dimensions less than 75 {mu}m, the sieve opening size. In this paper, for the first time, we capture true 3-D shape and size data of several different types of microfine aggregates, using X-ray microcomputed tomography ({mu}CT) with a voxel size of 2 {mu}m. This information is used to generate shape analyses of various kinds. Particle size distributions are also generated from the {mu}CT data and quantitatively compared to the results of laser diffraction, which is the leadingmore » method for measuring particle size distributions of sub-millimeter size particles. By taking into account the actual particle shape, the differences between {mu}CT and laser diffraction can be qualitatively explained.« less
A microcomputer program for analysis of nucleic acid hybridization data
Green, S.; Field, J.K.; Green, C.D.; Beynon, R.J.
1982-01-01
The study of nucleic acid hybridization is facilitated by computer mediated fitting of theoretical models to experimental data. This paper describes a non-linear curve fitting program, using the `Patternsearch' algorithm, written in BASIC for the Apple II microcomputer. The advantages and disadvantages of using a microcomputer for local data processing are discussed. Images PMID:7071017
Elian, Nicolas; Bloom, Mitchell; Dard, Michel; Cho, Sang-Choon; Trushkowsky, Richard D; Tarnow, Dennis
2014-02-01
The purpose of this study was to assess the effect of inter-implant distance on interproximal bone utilizing platform switching. Analysis of interproximal bone usually depends on traditional two-dimensional radiographic assessment. Although there has been increased reliability of current techniques, there has been an inability to track bone level changes over time and in three dimensions. Micro-CT has provided three-dimensional imaging that can be used in conjunction with traditional two-dimensional radiographic techniques. This study was performed on 24 female minipigs. Twelve animals received three implants with an inter-implant distance of 3 mm on one side of the mandible and another three implants on the contra-lateral side, where the implants were placed 2 mm apart creating a split mouth design. Twelve other animals received three implants with an inter-implant distance of 3 mm on one side of the mandible and another three implants on the contra-lateral side, where the implants were placed 4 mm apart creating a split mouth design too. The quantitative evaluation was performed comparatively on radiographs taken at t 0 (immediately after implantation) and at t 8 weeks (after termination). The samples were scanned by micro-computed tomography (μCT) to quantify the first bone to implant contact (fBIC) and bone volume/total volume (BV/TV). Mixed model regressions using the nonparametric Brunner-Langer method were used to determine the effect of inter-implant distance on the measured outcomes. The change in bone level was determined using radiography and its mean was 0.05 mm for an inter-implant distance of 3 and 0.00 mm for a 2 mm distance (P = 0.7268). The mean of this outcome was 0.18 mm for the 3 mm and for 4 mm inter-implant distance (P = 0.9500). Micro-computed tomography showed that the fBIC was always located above the reference, 0.27 and 0.20 mm for the comparison of 2-3 mm (P = 0.4622) and 0.49 and 0.34 mm for the inter-implant distance of 3 and 4 mm (P = 0.1699). BV/TV inside the defined parallelepipedic masks reached 82.38% for the 2 mm inter-implant distance and 85.00% for 3 mm, P = 0.8432. For the comparison of the 3-4 mm inter-implant distance, the means were 84.69% and 84.38%, respectively, P = 0.8401. Non-inferiority tests for the smaller inter-implant distances for both comparisons showed similar differences and similar tolerance ranges. The effect of a smaller interproximal distances between implants on bone level, fBIC and BV/TV assessed by two convergent investigation methods, radiology and μCT, was similar to that of larger distances. Implants can potentially be placed 2 mm apart instead of 3 mm and 3 mm apart instead of 4 mm when platform switching is utilized. Further research with a conventional platform is warranted. © 2012 John Wiley & Sons A/S.
Microcomputer Analysis of Children's Language Samples.
ERIC Educational Resources Information Center
Rosenkoetter, Sharon E.; Rice, Mabel L.
The workshop paper examines the use of microcomputer packages to analyze spontaneous language samples of children with communication disorders. Advantages of computerized analysis are seen to include time saving, more efficient data management, and increased objectivity. To help consumers determine which programs to buy, four aspects are…
Analysis of the mechanical behavior of a titanium scaffold with a repeating unit-cell substructure.
Ryan, Garrett; McGarry, Patrick; Pandit, Abhay; Apatsidis, Dimitrios
2009-08-01
Titanium scaffolds with controlled microarchitecture have been developed for load bearing orthopedic applications. The controlled microarchitecture refers to a repeating array of unit-cells, composed of sintered titanium powder, which make up the scaffold structure. The objective of this current research was to characterize the mechanical performance of three scaffolds with increasing porosity, using finite element analysis (FEA) and to compare the results with experimental data. Scaffolds were scanned using microcomputed tomography and FEA models were generated from the resulting computer models. Macroscale and unit-cell models of the scaffolds were created. The material properties of the sintered titanium powders were first evaluated in mechanical tests and the data used in the FEA. The macroscale and unit-cell FEA models proved to be a good predictor of Young's modulus and yield strength. Although macroscale models showed similar failure patterns and an expected trend in UCS, strain at UCS did not compare well with experimental data. Since a rapid prototyping method was used to create the scaffolds, the original CAD geometries of the scaffold were also evaluated using FEA but they did not reflect the mechanical properties of the physical scaffolds. This indicates that at present, determining the actual geometry of the scaffold through computed tomography imaging is important. Finally, a fatigue analysis was performed on the scaffold to simulate the loading conditions it would experience as a spinal interbody fusion device.
Cell Invasion in Collagen Scaffold Architectures Characterized by Percolation Theory.
Ashworth, Jennifer C; Mehr, Marco; Buxton, Paul G; Best, Serena M; Cameron, Ruth E
2015-06-24
The relationship between biological scaffold interconnectivity and cell migration is an important but poorly understood factor in tissue regeneration. Here a scale-independent technique for characterization of collagen scaffold interconnectivity is presented, using a combination of X-ray microcomputed tomography and percolation theory. Confocal microscopy of connective tissue cells reveals this technique as highly relevant for determining the extent of cell invasion. © 2015 The Authors. Published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Saito, Kazuya; Nomura, Shuhei; Yamamoto, Shuhei; Niiyama, Ryuma; Okabe, Yoji
2017-05-30
Ladybird beetles are high-mobility insects and explore broad areas by switching between walking and flying. Their excellent wing transformation systems enabling this lifestyle are expected to provide large potential for engineering applications. However, the mechanism behind the folding of their hindwings remains unclear. The reason is that ladybird beetles close the elytra ahead of wing folding, preventing the observation of detailed processes occurring under the elytra. In the present study, artificial transparent elytra were transplanted on living ladybird beetles, thereby enabling us to observe the detailed wing-folding processes. The result revealed that in addition to the abdominal movements mentioned in previous studies, the edge and ventral surface of the elytra, as well as characteristic shaped veins, play important roles in wing folding. The structures of the wing frames enabling this folding process and detailed 3D shape of the hindwing were investigated using microcomputed tomography. The results showed that the tape spring-like elastic frame plays an important role in the wing transformation mechanism. Compared with other beetles, hindwings in ladybird beetles are characterized by two seemingly incompatible properties: ( i ) the wing rigidity with relatively thick veins and ( ii ) the compactness in stored shapes with complex crease patterns. The detailed wing-folding process revealed in this study is expected to facilitate understanding of the naturally optimized system in this excellent deployable structure.
Kato, A; Ohno, N
2009-03-01
The study of dental morphology is essential in terms of phylogeny. Advances in three-dimensional (3D) measurement devices have enabled us to make 3D images of teeth without destruction of samples. However, raw fundamental data on tooth shape requires complex equipment and techniques. An online database of 3D teeth models is therefore indispensable. We aimed to explore the basic methodology for constructing 3D teeth models, with application for data sharing. Geometric information on the human permanent upper left incisor was obtained using micro-computed tomography (micro-CT). Enamel, dentine, and pulp were segmented by thresholding of different gray-scale intensities. Segmented data were separately exported in STereo-Lithography Interface Format (STL). STL data were converted to Wavefront OBJ (OBJect), as many 3D computer graphics programs support the Wavefront OBJ format. Data were also applied to Quick Time Virtual Reality (QTVR) format, which allows the image to be viewed from any direction. In addition to Wavefront OBJ and QTVR data, the original CT series were provided as 16-bit Tag Image File Format (TIFF) images on the website. In conclusion, 3D teeth models were constructed in general-purpose data formats, using micro-CT and commercially available programs. Teeth models that can be used widely would benefit all those who study dental morphology.
Djasim, Urville Mardijanto; Wolvius, Eppo Bonne; Van Neck, Johan Wilhelm; Van Wamel, Annemieke; Weinans, Harrie; Van Der Wal, Karel George Hendrik
2008-04-01
To study the effect of two different frequencies of distraction on the quantity and architecture of bone regenerate using micro-computed tomography, and to determine whether radiographic and ultrasonographic bone-fill scores provide reliable predictive value for the amount of new bone in the distraction area. Twenty-six skeletally mature rabbits underwent three full days of latency, after which midface distraction was started. Low-frequency group (n=12): a distraction rate of 0.9 mm/d achieved by one daily activation for 11 days to create a 10mm distraction gap. High-frequency group (n=12): idem, but three daily activations were used instead of one. Control group (n=2) underwent no distraction. After 21 days of consolidation, bone-fill in the distraction area was assessed by means of ultrasonography and radiography. Micro-computed tomography was used to quantify new bone formation and bone architecture. Relative bone volume (BV/TV) showed a tendency towards a difference (P=0.09) between the low and high-frequency groups. No significant differences were found for bone architecture. No significant correlation between BV/TV values and bone-fill scores was found. An increase in rhythm from one to three activations daily does not create significantly more bone. Bone-fill score values provided no reliable predictive value for the amount of new bone formation.
Ni, Yusu; Dai, Peidong; Dai, Chunfu; Li, Huawei
2017-01-01
To explore the structural characteristics of the cochlea in three-dimensional (3D) detail using 3D micro-computed tomography (mCT) image reconstruction of the osseous labyrinth, with the aim of improving the structural design of electrodes, the selection of stimulation sites, and the effectiveness of cochlear implantation. Three temporal bones were selected from among adult donors' temporal bone specimens. A micro-CT apparatus (GE eXplore) was used to scan three specimens with a voxel resolution of 45 μm. We obtained about 460 slices/specimen, which produced abundant data. The osseous labyrinth images of three specimens were reconstructed from mCT. The cochlea and its spiral characteristics were measured precisely using Able Software 3D-DOCTOR. The 3D images of the osseous labyrinth, including the cochlea, vestibule, and semicircular canals, were reconstructed. The 3D models of the cochlea showed the spatial relationships and surface structural characteristics. Quantitative data concerning the cochlea and its spiral structural characteristics were analyzed with regard to cochlear implantation. The 3D reconstruction of mCT images clearly displayed the detailed spiral structural characteristics of the osseous labyrinth. Quantitative data regarding the cochlea and its spiral structural characteristics could help to improve electrode structural design, signal processing, and the effectiveness of cochlear implantation. Clin. Anat. 30:39-43, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Nomura, Shuhei; Yamamoto, Shuhei; Niiyama, Ryuma; Okabe, Yoji
2017-01-01
Ladybird beetles are high-mobility insects and explore broad areas by switching between walking and flying. Their excellent wing transformation systems enabling this lifestyle are expected to provide large potential for engineering applications. However, the mechanism behind the folding of their hindwings remains unclear. The reason is that ladybird beetles close the elytra ahead of wing folding, preventing the observation of detailed processes occurring under the elytra. In the present study, artificial transparent elytra were transplanted on living ladybird beetles, thereby enabling us to observe the detailed wing-folding processes. The result revealed that in addition to the abdominal movements mentioned in previous studies, the edge and ventral surface of the elytra, as well as characteristic shaped veins, play important roles in wing folding. The structures of the wing frames enabling this folding process and detailed 3D shape of the hindwing were investigated using microcomputed tomography. The results showed that the tape spring-like elastic frame plays an important role in the wing transformation mechanism. Compared with other beetles, hindwings in ladybird beetles are characterized by two seemingly incompatible properties: (i) the wing rigidity with relatively thick veins and (ii) the compactness in stored shapes with complex crease patterns. The detailed wing-folding process revealed in this study is expected to facilitate understanding of the naturally optimized system in this excellent deployable structure. PMID:28507159
Young, Simon; Kretlow, James D; Nguyen, Charles; Bashoura, Alex G; Baggett, L Scott; Jansen, John A; Wong, Mark; Mikos, Antonios G
2008-09-01
Vasculogenesis and angiogenesis have been studied for decades using numerous in vitro and in vivo systems, fulfilling the need to elucidate the mechanisms involved in these processes and to test potential therapeutic agents that inhibit or promote neovascularization. Bone tissue engineering in particular has benefited from the application of proangiogenic strategies, considering the need for an adequate vascular supply during healing and the challenges associated with the vascularization of scaffolds implanted in vivo. Conventional methods of assessing the in vivo angiogenic response to tissue-engineered constructs tend to rely on a two-dimensional assessment of microvessel density within representative histological sections without elaboration of the true vascular tree. The introduction of microcomputed tomography (micro-CT) has recently allowed investigators to obtain a diverse range of high-resolution, three-dimensional characterization of structures, including renal, coronary, and hepatic vascular networks, as well as bone formation within healing defects. To date, few studies have utilized micro-CT to study the vascular response to an implanted tissue engineering scaffold. In this paper, conventional in vitro and in vivo models for studying angiogenesis will be discussed, followed by recent developments in the use of micro-CT for vessel imaging in bone tissue engineering research. A new study demonstrating the potential of contrast-enhanced micro-CT for the evaluation of in vivo neovascularization in bony defects is described, which offers significant potential in the evaluation of bone tissue engineering constructs.
Richards, Cameron S; Simonsen, Thomas J; Abel, Richard L; Hall, Martin J R; Schwyn, Daniel A; Wicklein, Martina
2012-07-10
We demonstrate how micro-computed tomography (micro-CT) can be a powerful tool for describing internal and external morphological changes in Calliphora vicina (Diptera: Calliphoridae) during metamorphosis. Pupae were sampled during the 1st, 2nd, 3rd and 4th quarter of development after the onset of pupariation at 23 °C, and placed directly into 80% ethanol for preservation. In order to find the optimal contrast, four batches of pupae were treated differently: batch one was stained in 0.5M aqueous iodine for 1 day; two for 7 days; three was tagged with a radiopaque dye; four was left unstained (control). Pupae stained for 7d in iodine resulted in the best contrast micro-CT scans. The scans were of sufficiently high spatial resolution (17.2 μm) to visualise the internal morphology of developing pharate adults at all four ages. A combination of external and internal morphological characters was shown to have the potential to estimate the age of blowfly pupae with a higher degree of accuracy and precision than using external morphological characters alone. Age specific developmental characters are described. The technique could be used as a measure to estimate a minimum post-mortem interval in cases of suspicious death where pupae are the oldest stages of insect evidence collected. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
Wang, Yunji; Chai, Zhaowu; Zhang, Yuanyuan; Deng, Feng; Wang, Zhibiao; Song, Jinlin
2014-08-01
This study was conducted to evaluate, with micro-computed tomography, the influence of low-intensity pulsed ultrasound on wound-healing in periodontal tissues. Periodontal disease with Class II furcation involvement was surgically produced at the bilateral mandibular premolars in 8 adult male beagle dogs. Twenty-four teeth were randomly assigned among 4 groups (G): G1, periodontal flap surgery; G2, periodontal flap surgery+low-intensity pulsed ultrasound (LIPUS); G3, guided tissue regeneration (GTR) surgery; G4, GTR surgery plus LIPUS. The affected area in the experimental group was exposed to LIPUS. At 6 and 8weeks, the X-ray images of regenerated teeth were referred to micro-CT scanning for 3-D measurement. Bone volume (BV), bone surface (BS), and number of trabeculae (Tb) in G2 and G4 were higher than in G1 and G3 (p<0.05). BV, BS, and Tb.N of the GTR+LIPUS group were higher than in the GTR group. BV, BS, and Tb.N of the LIPUS group were higher than in the periodontal flap surgery group. LIPUS irradiation increased the number, volume, and area of new alveolar bone trabeculae. LIPUS has the potential to promote the repair of periodontal tissue, and may work effectively if combined with GTR. Copyright © 2014 Elsevier B.V. All rights reserved.
Schroeder, A A; Ford, N L; Coil, J M
2017-03-01
To determine whether post space preparation deviated from the root canal preparation in canals filled with Thermafil, GuttaCore or warm vertically compacted gutta-percha. Forty-two extracted human permanent maxillary lateral incisors were decoronated, and their root canals instrumented using a standardized protocol. Samples were divided into three groups and filled with Thermafil (Dentsply Tulsa Dental Specialties, Johnson City, TN, USA), GuttaCore (Dentsply Tulsa Dental Specialties) or warm vertically compacted gutta-percha, before post space preparation was performed with a GT Post drill (Dentsply Tulsa Dental Specialties). Teeth were scanned using micro-computed tomography after root filling and again after post space preparation. Scans were examined for number of samples with post space deviation, linear deviation of post space preparation and minimum root thickness before and after post space preparation. Parametric data were analysed with one-way analysis of variance (anova) or one-tailed paired Student's t-tests, whilst nonparametric data were analysed with Fisher's exact test. Deviation occurred in eight of forty-two teeth (19%), seven of fourteen from the Thermafil group (50%), one of fourteen from the GuttaCore group (7%), and none from the gutta-percha group. Deviation occurred significantly more often in the Thermafil group than in each of the other two groups (P < 0.05). Linear deviation of post space preparation was greater in the Thermafil group than in both of the other groups and was significantly greater than that of the gutta-percha group (P < 0.05). Minimum root thickness before post space preparation was significantly greater than it was after post space preparation for all groups (P < 0.01). The differences between the Thermafil, GuttaCore and gutta-percha groups in the number of samples with post space deviation and in linear deviation of post space preparation were associated with the presence or absence of a carrier as well as the different carrier materials. © 2016 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Microcomputers and Stimulus Control: From the Laboratory to the Classroom.
ERIC Educational Resources Information Center
LeBlanc, Judith M.; And Others
1985-01-01
The need for developing a technology of teaching that equals current sophistication of microcomputer technology is addressed. The importance of principles of learning and behavior analysis is emphasized. Potential roles of stimulus control and precise error analysis in educational program development and in prescription of specific learning…
ERIC Educational Resources Information Center
Jones, Lawrence; Graham, Ian
1986-01-01
Reviews the main principles of interfacing and discusses the software developed to perform kinetic data capture and analysis with a BBC microcomputer linked to a recording spectrophotometer. Focuses on the steps in software development. Includes results of a lactate dehydrogenase assay. (ML)
High resolution image processing on low-cost microcomputers
NASA Technical Reports Server (NTRS)
Miller, R. L.
1993-01-01
Recent advances in microcomputer technology have resulted in systems that rival the speed, storage, and display capabilities of traditionally larger machines. Low-cost microcomputers can provide a powerful environment for image processing. A new software program which offers sophisticated image display and analysis on IBM-based systems is presented. Designed specifically for a microcomputer, this program provides a wide-range of functions normally found only on dedicated graphics systems, and therefore can provide most students, universities and research groups with an affordable computer platform for processing digital images. The processing of AVHRR images within this environment is presented as an example.
NASA Astrophysics Data System (ADS)
Ye, L. L.; Xue, Y. L.; Ni, L. H.; Tan, H.; Wang, Y. D.; Xiao, T. Q.
2013-07-01
Nondestructive and in situ investigation to the characteristic microstructures are important to the identification of traditional Chinese medicines (TCMs), especially for precious specimens and samples with oil contains. X-ray phase contrast micro-tomography (XPCMT) could be a practical solution for this kind of investigation. Fructus Foeniculi, a fruit kind of TCMs, is selected as the test sample. Experimental results show that the characteristic microstructures of Fructus Foeniculi, including vittae, vascular bundles, embryo, endosperm and the mesocarp reticulate cells around the vittae can be clearly distinguished and the integrated dissepiments microstructure in the vittae was observed successfully. Especially, for the first time, with virtual slice technique, it can investigate the liquid contains inside the TCMs. The results show that the vittae filled with volatile oil in the oil chamber were observed with this nondestructive and in situ 3-dimensional imaging technique. Furthermore, taking the advantage of micro-computed tomography, we can obtain the characteristic microstructures' quantitative information of the volume in liquid state. The volume of the oil chambers and the volatile oil, which are contained inside the vittae, was quantitatively analyzed. Accordingly, it can calculate the volume ratio of the volatile oil easily and accurately. As a result, we could conclude that XPCMT could be a useful tool for the nondestructive identification and quantitative analysis to TCMs.
Ho, Ming-Hua; Yao, Chih-Jung; Liao, Mei-Hsiu; Lin, Pei-I; Liu, Shing-Hwa; Chen, Ruei-Ming
2015-01-01
Osteoblasts play critical roles in bone formation. Our previous study showed that chitosan nanofibers can stimulate osteoblast proliferation and maturation. This translational study used an animal model of bone defects to evaluate the effects of chitosan nanofiber scaffolds on bone healing and the possible mechanisms. In this study, we produced uniform chitosan nanofibers with fiber diameters of approximately 200 nm. A bone defect was surgically created in the proximal femurs of male C57LB/6 mice, and then the left femur was implanted with chitosan nanofiber scaffolds for 21 days and compared with the right femur, which served as a control. Histological analyses revealed that implantation of chitosan nanofiber scaffolds did not lead to hepatotoxicity or nephrotoxicity. Instead, imaging analyses by X-ray transmission and microcomputed tomography showed that implantation of chitosan nanofiber scaffolds improved bone healing compared with the control group. In parallel, microcomputed tomography and bone histomorphometric assays further demonstrated augmentation of the production of new trabecular bone in the chitosan nanofiber-treated group. Furthermore, implantation of chitosan nanofiber scaffolds led to a significant increase in the trabecular bone thickness but a reduction in the trabecular parameter factor. As to the mechanisms, analysis by confocal microscopy showed that implantation of chitosan nanofiber scaffolds increased levels of Runt-related transcription factor 2 (Runx2), a key transcription factor that regulates osteogenesis, in the bone defect sites. Successively, amounts of alkaline phosphatase and osteocalcin, two typical biomarkers that can simulate bone maturation, were augmented following implantation of chitosan nanofiber scaffolds. Taken together, this translational study showed a beneficial effect of chitosan nanofiber scaffolds on bone healing through stimulating trabecular bone production due to upregulation of Runx2-mediated alkaline phosphatase and osteocalcin gene expressions. Our results suggest the potential of chitosan nanofiber scaffolds for therapy of bone diseases, including bone defects and bone fractures. PMID:26451104
Li, Dongxia; Jiang, Shan; Yin, Xingzhe; Chang, Jeffrey Wen Wei; Ke, Jie; Zhang, Chengfei
2015-06-01
The aim of this in vitro study was to use high-resolution micro-computed tomography (micro-CT) and scanning electron microscopy (SEM) to compare the efficacy of four irrigation techniques [needle, ultrasonic, EndoActivator, and photon-induced photoacoustic streaming (PIPS)] in removing calcium hydroxide (Ca[OH]2) from the root canal and isthmus of maxillary premolars. Twenty-four maxillary first premolars were selected based on the presence of isthmus regions on micro-CT scans. Root canals were instrumented with an F2 file using ProTaper rotary instruments and filled with Ca(OH)2 paste. Samples were stored at 37°C and 100% humidity for 1 week and randomly divided into four groups (n=6 each), according to irrigation technique. Samples were scanned with micro-CT before instrumentation, after Ca(OH)2 filling, and after irrigation. Ca(OH)2 reduction in the coronal, middle, and apical thirds and in the isthmus were assessed with three-dimensional image analysis. Next, specimens were split longitudinally, and canal walls were examined with SEM for Ca(OH)2 residues. Data were statistically evaluated with the Kruskal-Wallis and Mann-Whitney tests (p=0.05). The PIPS and ultrasonic groups showed greater Ca(OH)2 reduction in the apical third and higher cleanliness of the isthmus than the EndoActivator and needle irrigation groups (p<0.05). Ca(OH)2 residue scores in the PIPS and ultrasonic groups were significantly lower than those in the EndoActivator and needle groups in all regions of the root canals (p<0.05). There was no significant difference between PIPS and ultrasonic groups (p>0.05), or between EndoActivator and needle groups (p>0.05). PIPS and ultrasonic irrigation more effectively removed Ca(OH)2 from the main canal and isthmus in maxillary premolars than did EndoActivator or needle irrigation.
Kanczler, Janos M; Smith, Emma L; Roberts, Carol A; Oreffo, Richard O C
2012-10-01
Understanding the structural development of embryonic bone in a three dimensional framework is fundamental to developing new strategies for the recapitulation of bone tissue in latter life. We present an innovative combined approach of an organotypic embryonic femur culture model, microcomputed tomography (μCT) and immunohistochemistry to examine the development and modulation of the three dimensional structures of the developing embryonic femur. Isolated embryonic chick femurs were organotypic (air/liquid interface) cultured for 10 days in either basal, chondrogenic, or osteogenic supplemented culture conditions. The growth development and modulating effects of basal, chondrogenic, or osteogenic culture media of the embryonic chick femurs was investigated using μCT, immunohistochemistry, and histology. The growth and development of noncultured embryonic chick femur stages E10, E11, E12, E13, E15, and E17 were very closely correlated with increased morphometric indices of bone formation as determined by μCT. After 10 days in the organotpyic culture set up, the early aged femurs (E10 and E11) demonstrated a dramatic response to the chondrogenic or osteogenic culture conditions compared to the basal cultured femurs as determined by a change in μCT morphometric indices and modified expression of chondrogenic and osteogenic markers. Although the later aged femurs (E12 and E13) increased in size and structure after 10 days organotpypic culture, the effects of the osteogenic and chondrogenic organotypic cultures on these femurs were not significantly altered compared to basal conditions. We have demonstrated that the embryonic chick femur organotpyic culture model combined with the μCT and immunohistochemical analysis can provide an integral methodology for investigating the modulation of bone development in an ex vivo culture setting. Hence, these interdisciplinary techniques of μCT and whole organ bone cultures will enable us to delineate some of the temporal, structural developmental paradigms and modulation of bone tissue formation to underpin innovative skeletal regenerative technology for clinical therapeutic strategies in musculoskeletal trauma and diseases.
ERIC Educational Resources Information Center
Schuh, Merlyn D.
1988-01-01
Describes a biophysical chemistry experiment that introduces students to globular protein conformation and microcomputer analysis of initial rate data for the unfolding of proteins. Presents background, materials needed and methodology. Uses a visible spectrometer for analysis. Lists educational benefits derived from the experiment. (ML)
Microcomputers, Software and Foreign Languages for Special Purposes: An Analysis of TXTPRO.
ERIC Educational Resources Information Center
Tang, Michael S.
TXTPRO, a computer program developed as a graduate-level research tool for descriptive linguistic analysis, produces simple alphabetic and word frequency lists, analyzes word combinations, and develops concordances. With modifications, a teacher could enter the program into a mainframe or a microcomputer and use it for text analyses to develop…
Mathematical filtering minimizes metallic halation of titanium implants in MicroCT images.
Ha, Jee; Osher, Stanley J; Nishimura, Ichiro
2013-01-01
Microcomputed tomography (MicroCT) images containing titanium implant suffer from x-rays scattering, artifact and the implant surface is critically affected by metallic halation. To improve the metallic halation artifact, a nonlinear Total Variation denoising algorithm such as Split Bregman algorithm was applied to the digital data set of MicroCT images. This study demonstrated that the use of a mathematical filter could successfully reduce metallic halation, facilitating the osseointegration evaluation at the bone implant interface in the reconstructed images.
Nucleation and growth of chimney pores during electron-beam additive manufacturing
Cordero, Zachary C.; Dinwiddie, Ralph B.; Immel, David; ...
2016-12-05
The nucleation and growth of chimney pores during powder-bed, electron-beam additive manufacturing is investigated using in-situ infrared thermography as well as microcomputed tomography of as-printed parts. The pores are found to nucleate at dimples on the part s surface, clearly demonstrating how process parameters can affect surface roughness, which can in turn affect the internal defect structure in an additive manufactured part. Based on the results of this study, several strategies for suppressing the formation of chimney pores are discussed.
Contrast Agents for Micro-Computed Tomography of Microdamage in Bone
2008-01-01
4 × 50–60 mm, were sectioned from the cortex at the mid-diaphysis of a single bovine tibia. Two symmetric notches were machined on the periosteal ...endosteal surface, 0.6 mm from the periosteal surface and 0.2 mm from the beam sides (Fig. 2). Gaussian smoothing was applied to suppress noise and 3D...microdamage in trabecular bone with barium sulfate (BaSO4); (2) apply the technique to detect microdamage induced in bovine tibial trabecular bone specimens
The Ardipithecus ramidus skull and its implications for hominid origins.
Suwa, Gen; Asfaw, Berhane; Kono, Reiko T; Kubo, Daisuke; Lovejoy, C Owen; White, Tim D
2009-10-02
The highly fragmented and distorted skull of the adult skeleton ARA-VP-6/500 includes most of the dentition and preserves substantial parts of the face, vault, and base. Anatomical comparisons and micro-computed tomography-based analysis of this and other remains reveal pre-Australopithecus hominid craniofacial morphology and structure. The Ardipithecus ramidus skull exhibits a small endocranial capacity (300 to 350 cubic centimeters), small cranial size relative to body size, considerable midfacial projection, and a lack of modern African ape-like extreme lower facial prognathism. Its short posterior cranial base differs from that of both Pan troglodytes and P. paniscus. Ar. ramidus lacks the broad, anteriorly situated zygomaxillary facial skeleton developed in later Australopithecus. This combination of features is apparently shared by Sahelanthropus, showing that the Mio-Pliocene hominid cranium differed substantially from those of both extant apes and Australopithecus.
Reinholz, Emilee L.; Roberts, Scott A.; Apblett, Christopher A.; ...
2016-06-11
The electrical conductivity is key to the performance of thermal battery cathodes. In this work we present the effects of manufacturing and processing conditions on the electrical conductivity of Li/FeS2 thermal battery cathodes. Finite element simulations were used to compute the conductivity of three-dimensional microcomputed tomography cathode microstructures and compare results to experimental impedance spectroscopy measurements. A regression analysis reveals a predictive relationship between composition, processing conditions, and electrical conductivity; a trend which is largely erased after thermally-induced deformation. Moreover, the trend applies to both experimental and simulation results, although is not as apparent in simulations. This research is amore » step toward a more fundamental understanding of the effects of processing and composition on thermal battery component microstructure, properties, and performance.« less
MARS: a mouse atlas registration system based on a planar x-ray projector and an optical camera
NASA Astrophysics Data System (ADS)
Wang, Hongkai; Stout, David B.; Taschereau, Richard; Gu, Zheng; Vu, Nam T.; Prout, David L.; Chatziioannou, Arion F.
2012-10-01
This paper introduces a mouse atlas registration system (MARS), composed of a stationary top-view x-ray projector and a side-view optical camera, coupled to a mouse atlas registration algorithm. This system uses the x-ray and optical images to guide a fully automatic co-registration of a mouse atlas with each subject, in order to provide anatomical reference for small animal molecular imaging systems such as positron emission tomography (PET). To facilitate the registration, a statistical atlas that accounts for inter-subject anatomical variations was constructed based on 83 organ-labeled mouse micro-computed tomography (CT) images. The statistical shape model and conditional Gaussian model techniques were used to register the atlas with the x-ray image and optical photo. The accuracy of the atlas registration was evaluated by comparing the registered atlas with the organ-labeled micro-CT images of the test subjects. The results showed excellent registration accuracy of the whole-body region, and good accuracy for the brain, liver, heart, lungs and kidneys. In its implementation, the MARS was integrated with a preclinical PET scanner to deliver combined PET/MARS imaging, and to facilitate atlas-assisted analysis of the preclinical PET images.
MARS: a mouse atlas registration system based on a planar x-ray projector and an optical camera.
Wang, Hongkai; Stout, David B; Taschereau, Richard; Gu, Zheng; Vu, Nam T; Prout, David L; Chatziioannou, Arion F
2012-10-07
This paper introduces a mouse atlas registration system (MARS), composed of a stationary top-view x-ray projector and a side-view optical camera, coupled to a mouse atlas registration algorithm. This system uses the x-ray and optical images to guide a fully automatic co-registration of a mouse atlas with each subject, in order to provide anatomical reference for small animal molecular imaging systems such as positron emission tomography (PET). To facilitate the registration, a statistical atlas that accounts for inter-subject anatomical variations was constructed based on 83 organ-labeled mouse micro-computed tomography (CT) images. The statistical shape model and conditional Gaussian model techniques were used to register the atlas with the x-ray image and optical photo. The accuracy of the atlas registration was evaluated by comparing the registered atlas with the organ-labeled micro-CT images of the test subjects. The results showed excellent registration accuracy of the whole-body region, and good accuracy for the brain, liver, heart, lungs and kidneys. In its implementation, the MARS was integrated with a preclinical PET scanner to deliver combined PET/MARS imaging, and to facilitate atlas-assisted analysis of the preclinical PET images.
NASA Astrophysics Data System (ADS)
Moser, Dorothee; Poelchau, Michael H.; Stark, Florian; Grosse, Christian
2013-01-01
Within the framework of the Multidisciplinary Experimental and Modeling Impact Research Network (MEMIN) research group, the damage zones underneath two experimentally produced impact craters in sandstone targets were investigated using several nondestructive testing (NDT) methods. The 20 × 20 × 20 cm sandstones were impacted by steel projectiles with a radius of 1.25 mm at approximately 5 km s-1, resulting in craters with approximately 6 cm diameter and approximately 1 cm depth. Ultrasound (US) tomography and vibrational analysis were applied before and after the impact experiments to characterize the damage zone, and micro-computer tomography (μ-CT) measurements were performed to visualize subsurface fractures. The newly obtained experimental data can help to quantify the extent of the damage zone, which extends to about 8 cm depth in the target. The impacted sandstone shows a local p-wave reduction of 18% below the crater floor, and a general reduction in elastic moduli by between approximately 9 and approximately 18%, depending on the type of elastic modulus. The results contribute to a better empirical and theoretical understanding of hypervelocity events and simulations of cratering processes.
Trench fast reactor design using the microcomputer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rohach, A.F.; Sankoorikal, J.T.; Schmidt, R.R.
1987-01-01
This project is a study of alternative liquid-metal-cooled fast power reactor system concepts. Specifically, an unconventional primary system is being conceptually designed and evaluated. The project design is based primarily on microcomputer analysis through the use of computational modules. The reactor system concept is a long, narrow pool with a long, narrow reactor called a trench-type pool reactor in it. The reactor consists of five core-blanket modules in a line. Specific power is to be modest, permitting long fuel residence time. Two fuel cycles are currently being considered. The reactor design philosophy is that of the inherently safe concept. Thismore » requires transient analysis dependent on reactivity coefficients: prompt fuel, including Doppler and expansion, fuel expansion, sodium temperature and void, and core expansion. Conceptual reactor design is done on a microcomputer. A part of the trench reactor project is to develop a microcomputer-based system that can be used by the user for scoping studies and design. Current development includes the neutronics and fuel management aspects of the design. Thermal-hydraulic analysis and economics are currently being incorporated into the microcomputer system. The system is menu-driven including preparation of program input data and of output data for displays in graphics form.« less
Laboratory x-ray micro-computed tomography: a user guideline for biological samples
2017-01-01
Abstract Laboratory x-ray micro–computed tomography (micro-CT) is a fast-growing method in scientific research applications that allows for non-destructive imaging of morphological structures. This paper provides an easily operated “how to” guide for new potential users and describes the various steps required for successful planning of research projects that involve micro-CT. Background information on micro-CT is provided, followed by relevant setup, scanning, reconstructing, and visualization methods and considerations. Throughout the guide, a Jackson's chameleon specimen, which was scanned at different settings, is used as an interactive example. The ultimate aim of this paper is make new users familiar with the concepts and applications of micro-CT in an attempt to promote its use in future scientific studies. PMID:28419369
In vivo quantitative bioluminescence tomography using heterogeneous and homogeneous mouse models.
Liu, Junting; Wang, Yabin; Qu, Xiaochao; Li, Xiangsi; Ma, Xiaopeng; Han, Runqiang; Hu, Zhenhua; Chen, Xueli; Sun, Dongdong; Zhang, Rongqing; Chen, Duofang; Chen, Dan; Chen, Xiaoyuan; Liang, Jimin; Cao, Feng; Tian, Jie
2010-06-07
Bioluminescence tomography (BLT) is a new optical molecular imaging modality, which can monitor both physiological and pathological processes by using bioluminescent light-emitting probes in small living animal. Especially, this technology possesses great potential in drug development, early detection, and therapy monitoring in preclinical settings. In the present study, we developed a dual modality BLT prototype system with Micro-computed tomography (MicroCT) registration approach, and improved the quantitative reconstruction algorithm based on adaptive hp finite element method (hp-FEM). Detailed comparisons of source reconstruction between the heterogeneous and homogeneous mouse models were performed. The models include mice with implanted luminescence source and tumor-bearing mice with firefly luciferase report gene. Our data suggest that the reconstruction based on heterogeneous mouse model is more accurate in localization and quantification than the homogeneous mouse model with appropriate optical parameters and that BLT allows super-early tumor detection in vivo based on tomographic reconstruction of heterogeneous mouse model signal.
Optical coherence tomography for embryonic imaging: a review
Raghunathan, Raksha; Singh, Manmohan; Dickinson, Mary E.; Larin, Kirill V.
2016-01-01
Abstract. Embryogenesis is a highly complex and dynamic process, and its visualization is crucial for understanding basic physiological processes during development and for identifying and assessing possible defects, malformations, and diseases. While traditional imaging modalities, such as ultrasound biomicroscopy, micro-magnetic resonance imaging, and micro-computed tomography, have long been adapted for embryonic imaging, these techniques generally have limitations in their speed, spatial resolution, and contrast to capture processes such as cardiodynamics during embryogenesis. Optical coherence tomography (OCT) is a noninvasive imaging modality with micrometer-scale spatial resolution and imaging depth up to a few millimeters in tissue. OCT has bridged the gap between ultrahigh resolution imaging techniques with limited imaging depth like confocal microscopy and modalities, such as ultrasound sonography, which have deeper penetration but poorer spatial resolution. Moreover, the noninvasive nature of OCT has enabled live imaging of embryos without any external contrast agents. We review how OCT has been utilized to study developing embryos and also discuss advances in techniques used in conjunction with OCT to understand embryonic development. PMID:27228503
Microcomputer data acquisition and control.
East, T D
1986-01-01
In medicine and biology there are many tasks that involve routine well defined procedures. These tasks are ideal candidates for computerized data acquisition and control. As the performance of microcomputers rapidly increases and cost continues to go down the temptation to automate the laboratory becomes great. To the novice computer user the choices of hardware and software are overwhelming and sadly most of the computer sales persons are not at all familiar with real-time applications. If you want to bill your patients you have hundreds of packaged systems to choose from; however, if you want to do real-time data acquisition the choices are very limited and confusing. The purpose of this chapter is to provide the novice computer user with the basics needed to set up a real-time data acquisition system with the common microcomputers. This chapter will cover the following issues necessary to establish a real time data acquisition and control system: Analysis of the research problem: Definition of the problem; Description of data and sampling requirements; Cost/benefit analysis. Choice of Microcomputer hardware and software: Choice of microprocessor and bus structure; Choice of operating system; Choice of layered software. Digital Data Acquisition: Parallel Data Transmission; Serial Data Transmission; Hardware and software available. Analog Data Acquisition: Description of amplitude and frequency characteristics of the input signals; Sampling theorem; Specification of the analog to digital converter; Hardware and software available; Interface to the microcomputer. Microcomputer Control: Analog output; Digital output; Closed-Loop Control. Microcomputer data acquisition and control in the 21st Century--What is in the future? High speed digital medical equipment networks; Medical decision making and artificial intelligence.
NASA Astrophysics Data System (ADS)
Bagley, B. C.; Whitney, M.; Rogers, K. C.
2012-12-01
Sauropods are the largest known terrestrial vertebrates and exhibit a greater ontogenetic variation in body size than any other taxon. More than 120 species of sauropods are known from the Jurassic and Cretaceous, and a wealth of specimens documents their enormous adult body sizes. Juvenile sauropods, in contrast, are rare. Though titanosaur eggs containing embryos have been recovered, to date the smallest known post-hatching juveniles are only a little less than half of known adult size, and details of the earliest stages of sauropod ontogeny remain particularly poorly understood. Here we report on two partial skeletons of hatchling Rapetosaurus krausei, a titanosaur from the Upper Cretaceous Maevarano Formation of Madagascar, and provide important new data on primary early stage growth rates in sauropods. The two partial skeletons come from different localities in the Anembalemba Member of the Maevarano Formation. There is no duplication of elements for either specimen. Comparison of greatest length ratios for appendicular elements to those of a complete sub-adult Rapetosaurus confirms that there are only two individuals present, that there is no significant allometry in Rapetosaurus postcranial ontogeny, and that each individual is less than 15% adult size. The smaller specimen includes a sacral neural arch, three caudal centra, three caudal neural arches, left pubis, right femur (maximum length [ml] = 19.3 cm), tibia (ml = 12.7 cm), and metacarpal III, left and right fibulae, humeri, and metatarsal I, and a phalanx. The larger specimen includes a caudal centrum and neural arch, right metacarpal I, right tibia (ml = 17.9 cm), and left metacarpal IV. In order to non-destructively sample these exceptional Rapetosaurus juvenile elements, we employed micro-computed tomography to garner bone histology data. The micro-computed tomography was carried out using an X5000 high-resolution microfocus X-ray CT system located in the Department of Earth Sciences, University of Minnesota. The microfocus head has a minimum focal spot size of < 6 microns and the detector has a pixel pitch of 74.8 μm. Machine parameters (e.g. voltage, current, tube to detector distance) vary based on sample size and desired magnification. For this study 70-100 kV (260-370 μA) was sufficient to penetrate the samples and obtain good contrast. We were able to achieve an effective pixel pitch of 36-48 μm for the larger samples and 14-28 μm for sub-volumes. 2-D radiographs were collected and these data were reconstructed to produce a 3-D volume for visual analysis, and slices of the 3-D volume for quantitative analysis. Our results indicate that primary bone growth in Rapetosaurus is highly vascularized woven and fibrolamellar bone. However, even in these very small juvenile individuals, endosteal remodeling is common at the mid-diaphysis and extends in some areas into the mid-cortex. The presence of a single line of arrested growth is recorded in each individual. These results are surprising given the small size of the elements, and support the hypothesis that intensive remodeling observed in the bones of older juvenile Rapetosaurus may be dictated, at least in part, by resource limitations during periods of drought/ecological stress recorded in the Maevarano Formation of Madagascar.
The Microcomputer and School Transportation.
ERIC Educational Resources Information Center
Dembowski, Frederick L.
1984-01-01
Microcomputers have many cost- and time-saving uses in school transportation management. Applications include routing and scheduling, demographic analysis, fleet maintenance, and personnel and contract management. Word processing is especially promising for storing and updating documents like specifications. Enrollment forecasting and inventory…
The Application of Finite Element Solution Techniques in Structural Analysis on a Microcomputer.
1981-12-01
my wife for her support of this research project and the amount of time she spent helping me in preparation. Thanks go to the personnel at Computer...questions which had to be answered concerning the microcomputer in relation to a sequentially programmed finite element program. The first was how big...central site, then usefullness of the microcomputer is limited. The first series of problems consisted of a simple truss structure, which was expanded
Sun, Jirun; Eidelman, Naomi; Lin-Gibson, Sheng
2009-03-01
The objectives of this study were to (1) demonstrate X-ray micro-computed tomography (microCT) as a viable method for determining the polymerization shrinkage and microleakage on the same sample accurately and non-destructively, and (2) investigate the effect of sample geometry (e.g., C-factor and volume) on polymerization shrinkage and microleakage. Composites placed in a series of model cavities of controlled C-factors and volumes were imaged using microCT to determine their precise location and volume before and after photopolymerization. Shrinkage was calculated by comparing the volume of composites before and after polymerization and leakage was predicted based on gap formation between composites and cavity walls as a function of position. Dye penetration experiments were used to validate microCT results. The degree of conversion (DC) of composites measured using FTIR microspectroscopy in reflectance mode was nearly identical for composites filled in all model cavity geometries. The shrinkage of composites calculated based on microCT results was statistically identical regardless of sample geometry. Microleakage, on the other hand, was highly dependent on the C-factor as well as the composite volume, with higher C-factors and larger volumes leading to a greater probability of microleakage. Spatial distribution of microleakage determined by microCT agreed well with results determined by dye penetration. microCT has proven to be a powerful technique in quantifying polymerization shrinkage and corresponding microleakage for clinically relevant cavity geometries.
Hegab, Ahmed E; Kameyama, Naofumi; Kuroda, Aoi; Kagawa, Shizuko; Yin, Yongjun; Ornitz, David; Betsuyaku, Tomoko
2016-05-20
Lung cancer is the most lethal cancer in the world. Intensive research is ongoing worldwide to identify new therapies for lung cancer. Several mouse models of lung cancer are being used to study the mechanism of cancer development and to experiment with various therapeutic strategies. However, the absence of a real-time technique to identify the development of tumor nodules in mice lungs and to monitor the changes in their size in response to various experimental and therapeutic interventions hampers the ability to obtain an accurate description of the course of the disease and its timely response to treatments. In this study, a method using a micro-computed tomography (CT) scanner for the detection of the development of lung tumors in a mouse model of lung adenocarcinoma is described. Next, we show that monthly follow-up with micro-CT can identify dynamic changes in the lung tumor, such as the appearance of additional nodules, increase in the size of previously detected nodules, and decrease in the size or complete resolution of nodules in response to treatment. Finally, the accuracy of this real-time assessment method was confirmed with end-point histological quantification. This technique paves the way for planning and conducting more complex experiments on lung cancer animal models, and it enables us to better understand the mechanisms of carcinogenesis and the effects of different treatment modalities while saving time and resources.
Braun, Katharina; Böhnke, Frank; Stark, Thomas
2012-06-01
We present a complete geometric model of the human cochlea, including the segmentation and reconstruction of the fluid-filled chambers scala tympani and scala vestibuli, the lamina spiralis ossea and the vibrating structure (cochlear partition). Future fluid-structure coupled simulations require a reliable geometric model of the cochlea. The aim of this study was to present an anatomical model of the human cochlea, which can be used for further numerical calculations. Using high resolution micro-computed tomography (µCT), we obtained images of a cut human temporal bone with a spatial resolution of 5.9 µm. Images were manually segmented to obtain the three-dimensional reconstruction of the cochlea. Due to the high resolution of the µCT data, a detailed examination of the geometry of the twisted cochlear partition near the oval and the round window as well as the precise illustration of the helicotrema was possible. After reconstruction of the lamina spiralis ossea, the cochlear partition and the curved geometry of the scala vestibuli and the scala tympani were presented. The obtained data sets were exported as standard lithography (stl) files. These files represented a complete framework for future numerical simulations of mechanical (acoustic) wave propagation on the cochlear partition in the form of mathematical mechanical cochlea models. Additional quantitative information concerning heights, lengths and volumes of the scalae was found and compared with previous results.
Cengiz, Ibrahim Fatih; Oliveira, Joaquim Miguel; Reis, Rui L
2017-08-01
Quantitative assessment of micro-structure of materials is of key importance in many fields including tissue engineering, biology, and dentistry. Micro-computed tomography (µ-CT) is an intensively used non-destructive technique. However, the acquisition parameters such as pixel size and rotation step may have significant effects on the obtained results. In this study, a set of tissue engineering scaffolds including examples of natural and synthetic polymers, and ceramics were analyzed. We comprehensively compared the quantitative results of µ-CT characterization using 15 acquisition scenarios that differ in the combination of the pixel size and rotation step. The results showed that the acquisition parameters could statistically significantly affect the quantified mean porosity, mean pore size, and mean wall thickness of the scaffolds. The effects are also practically important since the differences can be as high as 24% regarding the mean porosity in average, and 19.5 h and 166 GB regarding the characterization time and data storage per sample with a relatively small volume. This study showed in a quantitative manner the effects of such a wide range of acquisition scenarios on the final data, as well as the characterization time and data storage per sample. Herein, a clear picture of the effects of the pixel size and rotation step on the results is provided which can notably be useful to refine the practice of µ-CT characterization of scaffolds and economize the related resources.
Young, Simon; Kretlow, James D.; Nguyen, Charles; Bashoura, Alex G.; Baggett, L. Scott; Jansen, John A.; Wong, Mark
2008-01-01
Abstract Vasculogenesis and angiogenesis have been studied for decades using numerous in vitro and in vivo systems, fulfilling the need to elucidate the mechanisms involved in these processes and to test potential therapeutic agents that inhibit or promote neovascularization. Bone tissue engineering in particular has benefited from the application of proangiogenic strategies, considering the need for an adequate vascular supply during healing and the challenges associated with the vascularization of scaffolds implanted in vivo. Conventional methods of assessing the in vivo angiogenic response to tissue-engineered constructs tend to rely on a two-dimensional assessment of microvessel density within representative histological sections without elaboration of the true vascular tree. The introduction of microcomputed tomography (micro-CT) has recently allowed investigators to obtain a diverse range of high-resolution, three-dimensional characterization of structures, including renal, coronary, and hepatic vascular networks, as well as bone formation within healing defects. To date, few studies have utilized micro-CT to study the vascular response to an implanted tissue engineering scaffold. In this paper, conventional in vitro and in vivo models for studying angiogenesis will be discussed, followed by recent developments in the use of micro-CT for vessel imaging in bone tissue engineering research. A new study demonstrating the potential of contrast-enhanced micro-CT for the evaluation of in vivo neovascularization in bony defects is described, which offers significant potential in the evaluation of bone tissue engineering constructs. PMID:18657028
Koistinen, A P; Korhonen, H; Kiviranta, I; Kröger, H; Lappalainen, R
2011-07-01
Insertion of internal fracture fixation devices, such as screws, mechanically weakens the bone. Diamond-like carbon has outstanding tribology properties which may decrease the amount of damage in tissue. The purpose of this study was to investigate methods for quantification of cortical bone damage after orthopaedic bone screw insertion and to evaluate the effect of surface modification on tissue damage. In total, 48 stainless steel screws were inserted into cadaver bones. Half of the screws were coated with a smooth amorphous diamond coating. Geometrical data of the bones was determined by peripheral quantitative computed tomography. Thin sections of the bone samples were prepared after screw insertion, and histomorphometric evaluation of damage was performed on images obtained using light microscopy. Micro-computed tomography and scanning electron microscopy were also used to examine tissue damage. A positive correlation was found between tissue damage and the geometric properties of the bone. The age of the cadaver significantly affected the bone mineral density, as well as the damage perimeter and diameter of the screw hole. However, the expected positive effect of surface modification was probably obscured by large variations in the results and, thus, statistically significant differences were not found in this study. This can be explained by natural variability in bone tissue, which also made automated image analysis difficult.
Fu, Jianwei; Yang, Xiaoquan; Wang, Kan; Luo, Qingming; Gong, Hui
2011-12-01
A combined system of fluorescence molecular tomography and microcomputed tomography (FMT&mCT) can provide molecular and anatomical information of small animals in a single study with intrinsically coregistered images. The anatomical information provided by the mCT subsystem is commonly used as a reference to locate the fluorophore distribution or as a priori structural information to improve the performance of FMT. Therefore, the transformation between the coordinate systems of the subsystem needs to be determined in advanced. A cocalibration method for the combined system of FMT&mCT is proposed. First, linear models are adopted to describe the galvano mirrors and the charge-coupled device (CCD) camera in the FMT subsystem. Second, the position and orientation of the galvano mirrors are determined with the input voltages of the galvano mirrors and the markers, whose positions are predetermined. The position, orientation and normalized pixel size of the CCD camera are obtained by analysing the projections of a point-like marker at different positions. Finally, the orientation and position of sources and the corresponding relationship between the detectors and their projections on the image plane are predicted. Because the positions of the markers are acquired with mCT, the registration of the FMT and mCT could be realized by direct image fusion. The accuracy and consistency of this method in the presence of noise is evaluated by computer simulation. Next, a practical implementation for an experimental FMT&mCT system is carried out and validated. The maximum prediction error of the source positions on the surface of a cylindrical phantom is within 0.375 mm and that of the projections of a point-like marker is within 0.629 pixel. Finally, imaging experiments of the fluorophore distribution in a cylindrical phantom and a phantom with a complex shape demonstrate the feasibility of the proposed method. This method is universal in FMT&mCT, which could be performed with no restriction on the system geometry, calibration phantoms or imaging objects.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fu Jianwei; Yang Xiaoquan; Wang Kan
2011-12-15
Purpose: A combined system of fluorescence molecular tomography and microcomputed tomography (FMT and mCT) can provide molecular and anatomical information of small animals in a single study with intrinsically coregistered images. The anatomical information provided by the mCT subsystem is commonly used as a reference to locate the fluorophore distribution or as a priori structural information to improve the performance of FMT. Therefore, the transformation between the coordinate systems of the subsystem needs to be determined in advanced. Methods: A cocalibration method for the combined system of FMT and mCT is proposed. First, linear models are adopted to describe themore » galvano mirrors and the charge-coupled device (CCD) camera in the FMT subsystem. Second, the position and orientation of the galvano mirrors are determined with the input voltages of the galvano mirrors and the markers, whose positions are predetermined. The position, orientation and normalized pixel size of the CCD camera are obtained by analysing the projections of a point-like marker at different positions. Finally, the orientation and position of sources and the corresponding relationship between the detectors and their projections on the image plane are predicted. Because the positions of the markers are acquired with mCT, the registration of the FMT and mCT could be realized by direct image fusion. Results: The accuracy and consistency of this method in the presence of noise is evaluated by computer simulation. Next, a practical implementation for an experimental FMT and mCT system is carried out and validated. The maximum prediction error of the source positions on the surface of a cylindrical phantom is within 0.375 mm and that of the projections of a point-like marker is within 0.629 pixel. Finally, imaging experiments of the fluorophore distribution in a cylindrical phantom and a phantom with a complex shape demonstrate the feasibility of the proposed method. Conclusions: This method is universal in FMT and mCT, which could be performed with no restriction on the system geometry, calibration phantoms or imaging objects.« less
ERIC Educational Resources Information Center
Lavonen, Jari; Juuti, Kalle; Meisalo, Veijo
2003-01-01
In this study we analyse how the experiences of chemistry teachers on the use of a Microcomputer-Based Laboratory (MBL), gathered by a Likert-scale instrument, can be utilized to develop the new package "Empirica 2000." We used exploratory factor analysis to identify the essential features in a large set of questionnaire data to see how…
1988-09-01
software programs capable of being used on a microcomputer will be considered for analysis. No software intended for use on a miniframe or mainframe...Dial-A-Log consists of a program written in a computer language called L-10 that is run on a DEC-20 miniframe . The combination of the specific...proliferation of software dealing with microcomputers. Instead, they were geared more towards managing the use of miniframe or mainframe computer
Non-destructive, high-content analysis of wheat grain traits using X-ray micro computed tomography.
Hughes, Nathan; Askew, Karen; Scotson, Callum P; Williams, Kevin; Sauze, Colin; Corke, Fiona; Doonan, John H; Nibau, Candida
2017-01-01
Wheat is one of the most widely grown crop in temperate climates for food and animal feed. In order to meet the demands of the predicted population increase in an ever-changing climate, wheat production needs to dramatically increase. Spike and grain traits are critical determinants of final yield and grain uniformity a commercially desired trait, but their analysis is laborious and often requires destructive harvest. One of the current challenges is to develop an accurate, non-destructive method for spike and grain trait analysis capable of handling large populations. In this study we describe the development of a robust method for the accurate extraction and measurement of spike and grain morphometric parameters from images acquired by X-ray micro-computed tomography (μCT). The image analysis pipeline developed automatically identifies plant material of interest in μCT images, performs image analysis, and extracts morphometric data. As a proof of principle, this integrated methodology was used to analyse the spikes from a population of wheat plants subjected to high temperatures under two different water regimes. Temperature has a negative effect on spike height and grain number with the middle of the spike being the most affected region. The data also confirmed that increased grain volume was correlated with the decrease in grain number under mild stress. Being able to quickly measure plant phenotypes in a non-destructive manner is crucial to advance our understanding of gene function and the effects of the environment. We report on the development of an image analysis pipeline capable of accurately and reliably extracting spike and grain traits from crops without the loss of positional information. This methodology was applied to the analysis of wheat spikes can be readily applied to other economically important crop species.
Microcomputer design and analysis of the cable catenary large space antenna system
NASA Technical Reports Server (NTRS)
Akle, W.
1984-01-01
The use of microcomputers in the design of a cable catenary large space antenna system is discussed. The development of a system design capability, data base utilization, systems integration, program structure and logic, and integrated graphics output are discussed.
Majkut, Patrycja; Sadr, Alireza; Shimada, Yasushi; Sumi, Yasunori; Tagami, Junji
2015-08-01
Optical coherence tomography (OCT) is a noninvasive modality to obtain in-depth images of biological structures. A dental OCT system has become available for chairside application. This in vitro study hypothesized that swept-source OCT can be used to measure the remaining dentin thickness (RDT) at the roof of the dental pulp chamber during excavation of deep caries. Human molar teeth with deep occlusal caries were investigated. After obtaining 2-dimensional and 3-dimensional OCT scans using a swept-source OCT system at a 1330-nm center wavelength, RDT was evaluated by image analysis software. Microfocus x-ray computed tomographic (micro-CT) images were obtained from the same cross sections to confirm OCT findings. The smallest RDT values at the visible pulp horn were measured on OCT and micro-CT imaging and compared using the Pearson correlation. Pulpal horns and pulp chamber roof observation under OCT and micro-CT imaging resulted in comparable images that allowed the measurement of coronal dentin thickness. RDT measured by OCT showed optical values range between 140 and 2300 μm, which corresponded to the range of 92-1524 μm on micro-CT imaging. A strong correlation was found between the 2 techniques (r = 0.96, P < .001). Further analysis indicated linear regression with a slope of 1.54 and no intercept, closely matching the bulk refractive index of dentin. OCT enables visualization of anatomic structures during deep caries excavation. Exposure of the vital dental pulp because of the removal of very thin remaining coronal dentin can be avoided with this novel noninvasive technique. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Training faculty in Bangladesh to use a microcomputer for public health: followup report.
Gould, J B; Frerichs, R R
1986-01-01
In 1984 the Western Consortium for the Health Professions, Inc., under contract to the United Nations Fund for Population Activities (UNFPA), began a project to assist Bangladesh's National Institute for Preventive and Social Medicine (NIPSOM) in establishing a microcomputing capability. The project's goal was to enable NIPSOM to become self-sufficient in the analysis by microcomputer of health, population, and family planning data; program evaluation; and policy activities. Lack of a local microcomputer infrastructure demanded that a local team of experts be developed to run the system described in a previous report. Five NIPSOM faculty members--three of whom had taken the workshop held when the system was first installed--were assigned to a computer committee, which was responsible for the computer's well-being. Six months after the microcomputer system was installed, a second 2-week workshop was given. The consortium's consultant facilitated the development of a basic microcomputer course, which was taught by four members of the computer committee to an additional eight NIPSOM faculty members. Emphasis was placed on developing local self-reliance and the need to overcome obstacles imposed by the lack of local hardware and software support systems. A strategy is proposed for the successful introduction of microcomputers in developing countries. PMID:3097742
Ge, Xueping; Ye, Qiang; Song, Linyong; Misra, Anil; Spencer, Paulette
2015-04-01
The effects of polymerization kinetics and chemical miscibility on the crosslinking structure and mechanical properties of polymers cured by visible-light initiated free-radical/cationic ring-opening hybrid photopolymerization are determined. A three-component initiator system is used and the monomer system contains methacrylates and epoxides. The photopolymerization kinetics is monitored in situ by Fourier transform infrared-attenuated total reflectance. The crosslinking structure is studied by modulated differential scanning calorimetry and dynamic mechanical analysis. X-ray microcomputed tomography is used to evaluate microphase separation. The mechanical properties of polymers formed by hybrid formed by free-radical polymerization. These investigations mark the first time that the benefits of the chain transfer reaction between epoxy and hydroxyl groups of methacrylate, on the crosslinking network and microphase separation during hybrid visible-light initiated photopolymerization, have been determined.
[Nasolabial muscle finite-element study and clinical application].
Yin, Ningbei; Wu, Jiajun; Chen, Bo; Wang, Yongqian; Song, Tao; Ma, Hengyuan
2015-05-01
To investigate the nasolabial muscle anatomy and biomechanical characteristics. Micro-computed tomography scan was performed in 8 cases of spontaneous abortion fetus lip nasal specimens to construct a three-dimensional model. The nasolabial muscle structure was analyzed using Mimics software. The three-dimensional configuration model of nasolabial muscle was established based on local anatomy and tissue section, and compared with tissue section. Three dimensional finite element analysis was performed on lip nasal muscle related biomechanics and surface deformation in Application verification was carried out in 263 cases of microform cleft lip surgery. There was close relationship between nasolabial muscle. The nasolabial muscle tension system was constituted, based on which a new cleft lip repair surgery was designed and satisfied results were achieved. There is close relationship among nasolabial muscle in anatomy, histology and biomechanics. To obtain better effect, cleft lip repair should be performed on the basis of recovering muscle tension system.
Qualification of Ti6Al4V ELI Alloy Produced by Laser Powder Bed Fusion for Biomedical Applications
NASA Astrophysics Data System (ADS)
Yadroitsev, I.; Krakhmalev, P.; Yadroitsava, I.; Du Plessis, A.
2018-03-01
Rectangular Ti6Al4V extralow interstitials (ELI) samples were manufactured by laser powder bed fusion (LPBF) in vertical and horizontal orientations relative to the build platform and subjected to various heat treatments. Detailed analyses of porosity, microstructure, residual stress, tensile properties, fatigue, and fracture surfaces were performed based on x-ray micro-computed tomography, scanning electron microscopy, and x-ray diffraction methods. The types of fracture and the tensile fracture mechanisms of the LPBF Ti6Al4V ELI alloy were also studied. Detailed analysis of the microstructure and the corresponding mechanical properties were compared against standard specifications for conventional Ti6Al4V alloy for use in surgical implant applications. Conclusions regarding the mechanical properties and heat treatment of LPBF Ti6Al4V ELI for biomedical applications are made.
A Bayesian Measurment Error Model for Misaligned Radiographic Data
Lennox, Kristin P.; Glascoe, Lee G.
2013-09-06
An understanding of the inherent variability in micro-computed tomography (micro-CT) data is essential to tasks such as statistical process control and the validation of radiographic simulation tools. The data present unique challenges to variability analysis due to the relatively low resolution of radiographs, and also due to minor variations from run to run which can result in misalignment or magnification changes between repeated measurements of a sample. Positioning changes artificially inflate the variability of the data in ways that mask true physical phenomena. We present a novel Bayesian nonparametric regression model that incorporates both additive and multiplicative measurement error inmore » addition to heteroscedasticity to address this problem. We also use this model to assess the effects of sample thickness and sample position on measurement variability for an aluminum specimen. Supplementary materials for this article are available online.« less
Analysis of the enamel hypoplasia using micro-CT scanner versus classical method.
Marchewka, Justyna; Skrzat, Janusz; Wróbel, Andrzej
2014-01-01
This article demonstrates the use of micro-CT scanning of the teeth surface for recognizing and evaluating severity of the enamel hypoplasia. To test capabilities of the microtomography versus classical method of evaluation hypoplastic defects of the enamel we selected two human teeth (C, M(2)) showing different types of enamel hypoplasia: linear, pits, and groove. Examined samples derive from archeological material dated on XVII-XVIII AD and excavated in Poland. In the current study we proved that micro-CT scanning is a powerful technique not only for imaging all kinds of the enamel hypoplasia but also allows to perform accurate measurements of the enamel defects. We figure out that contrary to the classical method of scoring enamel defects, the micro-computed tomography yields adequate data which serve for estimating the length of stress episode and length of interval between them.
The Role of Epithelial Stat3 in Amelogenesis during Mouse Incisor Renewal.
Zhang, Bin; Meng, Bo; Viloria, Edward; Naveau, Adrien; Ganss, Bernhard; Jheon, Andrew H
2018-03-16
The aim of this study was to evaluate the role of epithelial signal transducer and activator of transcription 3 (STAT3) in mouse incisor amelogenesis. Since Stat3 is expressed in the epithelial component of developing and adult mouse teeth, we generated and analyzed Krt14Cre/+;Stat3fl/fl mutant mice in which Stat3 was inactivated in epithelia including ameloblast progenitors and ameloblasts, the cells responsible for enamel formation. Histological analysis showed little enamel matrix in mutant incisors compared to controls. Delayed incisor enamel mineralization was demonstrated using micro-computed X-ray tomography analysis and was supported by an increase in the pre-expression distance of enamel-enriched proteins such as amelogenin, ameloblastin, and kallikrein-4. Lastly, scanning electron microscopy analysis showed little enamel mineralization in mutant incisors underneath the mesial root of the 1st molar; however, the micro-architecture of enamel mineralization was similar in the erupted portion of control and mutant incisors. Taken together, our findings demonstrate for the first time that the absence of epithelial Stat3 in mice leads to delayed incisor amelogenesis. © 2018 S. Karger AG, Basel.
The microcomputer scientific software series 3: general linear model--analysis of variance.
Harold M. Rauscher
1985-01-01
A BASIC language set of programs, designed for use on microcomputers, is presented. This set of programs will perform the analysis of variance for any statistical model describing either balanced or unbalanced designs. The program computes and displays the degrees of freedom, Type I sum of squares, and the mean square for the overall model, the error, and each factor...
Virtual reconstruction of the skeletal labyrinth of two lamnid sharks (Elasmobranchii, Lamniformes).
Schnetz, L; Kriwet, J; Pfaff, C
2017-03-01
The first virtual reconstruction of the skeletal labyrinth of the porbeagle shark Lamna nasus and the shortfin mako shark Isurus oxyrinchus is presented here using high-resolution micro-computed tomography. The results, in comparison with previously published information, suggest relationships between skeletal labyrinth morphology and locomotion mode in chondrichthyans, but also show that further studies are required to establish such connections. Nevertheless, this study adds to the knowledge of the skeletal labyrinth morphology in two apex elasmobranch species. © 2016 The Fisheries Society of the British Isles.
Assessment of Venous Thrombosis in Animal Models.
Grover, Steven P; Evans, Colin E; Patel, Ashish S; Modarai, Bijan; Saha, Prakash; Smith, Alberto
2016-02-01
Deep vein thrombosis and common complications, including pulmonary embolism and post-thrombotic syndrome, represent a major source of morbidity and mortality worldwide. Experimental models of venous thrombosis have provided considerable insight into the cellular and molecular mechanisms that regulate thrombus formation and subsequent resolution. Here, we critically appraise the ex vivo and in vivo techniques used to assess venous thrombosis in these models. Particular attention is paid to imaging modalities, including magnetic resonance imaging, micro-computed tomography, and high-frequency ultrasound that facilitate longitudinal assessment of thrombus size and composition. © 2015 American Heart Association, Inc.
Li, Mei-Lin; Liao, Wei-Li; Cai, Hua-Xiong
2018-01-01
The aim of the present study was to evaluate the length of dentinal microcracks observed prior to and following root canal preparation with different single-file nickel-titanium (Ni-Ti) systems using micro-computed tomography (micro-CT) analysis. A total of 80 mesial roots of mandibular first molars presenting with type II Vertucci canal configurations were scanned at an isotropic resolution of 7.4 µm. The samples were randomly assigned into four groups (n=20 per group) according to the system used for root canal preparation, including the WaveOne (WO), OneShape (OS), Reciproc (RE) and control groups. A second micro-CT scan was conducted after the root canals were prepared with size 25 instruments. Pre- and postoperative cross-section images of the roots (n=237,760) were then screened to identify the lengths of the microcracks. The results indicated that the microcrack lengths were notably increased following root canal preparation (P<0.05). The alterations in microcrack length in the OS group were more significant compared with those in the WO, RE and control groups (P<0.05). In conclusion, the formation and development of dentinal microcracks may be associated with the movement caused by preparation rather than the taper of the files. Among the single-file Ni-Ti systems, WO and RE were not observed to cause notable microcracks, while the OS system resulted in evident microcracks.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mok, G.C.; Thomas, G.R.; Gerhard, M.A.
SCANS (Shipping Cask ANalysis System) is a microcomputer-based system of computer programs and databases developed at the Lawrence Livermore National Laboratory (LLNL) for evaluating safety analysis reports on spent fuel shipping casks. SCANS is an easy-to-use system that calculates the global response to impact loads, pressure loads and thermal conditions, providing reviewers with an independent check on analyses submitted by licensees. SCANS is based on microcomputers compatible with the IBM-PC family of computers. The system is composed of a series of menus, input programs, cask analysis programs, and output display programs. All data is entered through fill-in-the-blank input screens thatmore » contain descriptive data requests. Analysis options are based on regulatory cases described in the Code of Federal Regulations 10 CFR 71 and Regulatory Guides published by the US Nuclear Regulatory Commission in 1977 and 1978.« less
Induction of SHP2 deficiency in chondrocytes causes severe scoliosis and kyphosis in mice.
Kim, Harry K W; Aruwajoye, Olumide; Sucato, Daniel; Richards, B Stephens; Feng, Gen-Sheng; Chen, Di; King, Philip D; Kamiya, Nobuhiro
2013-10-01
Genetic engineering techniques were used to develop an animal model of juvenile scoliosis during a postnatal skeletal-growth stage. To investigate the effect of targeted SHP2 (Src homology-2) deficiency in chondrocytes on the development of scoliosis during a juvenile growth stage in mice. Juvenile idiopathic scoliosis can lead to progressive severe spinal deformity. The pathophysiology and molecular mechanisms responsible for the deformity are unknown. Here, we investigated the role of SHP2 deficiency in chondrocytes as a potential cause of juvenile scoliosis. Genetically engineered mice with inducible deletion of SHP2 in chondrocytes were generated. The SHP2 function in chondrocytes was inactivated during a juvenile growth stage from the mouse age of 4 weeks. Radiographical, micro-computed tomographic, and histological assessments were used to analyze spinal changes. When SHP2 deficiency was induced during the juvenile stage, a progressive kyphoscoliotic deformity (thoracic lordosis and thoracolumbar kyphoscoliosis) developed within 2 weeks of the initiation of SHP2 deficiency. The 3-dimensional micro-computed tomography analysis confirmed the kyphoscoliotic deformity with a rotational deformity of the spine and osteophyte formation. The histological analysis revealed disorganization of the vertebral growth plate cartilage. Interestingly, when SHP2 was disrupted during the adolescent to adult stages, no spinal deformity developed. SHP2 plays an important role in normal spine development during skeletal maturation. Chondrocyte-specific deletion of SHP2 at a juvenile stage produced a kyphoscoliotic deformity. This new mouse model will be useful for future investigations of the role of SHP2 deficiency in chondrocytes as a mechanism leading to the development of juvenile scoliosis. N/A.
A microcomputer interface for a digital audio processor-based data recording system.
Croxton, T L; Stump, S J; Armstrong, W M
1987-10-01
An inexpensive interface is described that performs direct transfer of digitized data from the digital audio processor and video cassette recorder based data acquisition system designed by Bezanilla (1985, Biophys. J., 47:437-441) to an IBM PC/XT microcomputer. The FORTRAN callable software that drives this interface is capable of controlling the video cassette recorder and starting data collection immediately after recognition of a segment of previously collected data. This permits piecewise analysis of long intervals of data that would otherwise exceed the memory capability of the microcomputer.
A microcomputer interface for a digital audio processor-based data recording system.
Croxton, T L; Stump, S J; Armstrong, W M
1987-01-01
An inexpensive interface is described that performs direct transfer of digitized data from the digital audio processor and video cassette recorder based data acquisition system designed by Bezanilla (1985, Biophys. J., 47:437-441) to an IBM PC/XT microcomputer. The FORTRAN callable software that drives this interface is capable of controlling the video cassette recorder and starting data collection immediately after recognition of a segment of previously collected data. This permits piecewise analysis of long intervals of data that would otherwise exceed the memory capability of the microcomputer. PMID:3676444
The Spreadsheet in an Educational Setting. Microcomputing Working Paper Series F 84-4.
ERIC Educational Resources Information Center
Wozny, Lucy
This overview of a specific spreadsheet, Microsoft's Multiplan for the Apple Macintosh microcomputer, emphasizes specific features that are important to the academic community, including the mathematical functions of algebra, trigonometry, and statistical analysis. Additional features are summarized, including data formats for both numerical and…
Microcomputer Applications in Local Assessment Systems.
ERIC Educational Resources Information Center
Harnisch, Delwyn L.; And Others
The capabilities and hardware requirements of four microcomputer software packages produced by the Office of Educational Testing, Research and Service at the University of Illinois at Urbana-Champaign are described. These programs are: (1) the Scan-Tron Forms Analysis Package Version 2.0, an interface between an IBM-compatible and a Scan-Tron…
An Integrated Library System from Existing Microcomputer Programs.
ERIC Educational Resources Information Center
Kuntz, Lynda S.
1988-01-01
Demonstrates how three commercial microcomputer software packages--PC-Talk III, Wordstar, and dBase III--were combined to produce an integrated library system at the U.S. Army Concepts Analysis Agency library. The retrospective conversion process is discussed, and the four modules of the system are described: acquisitions/cataloging; online…
ERIC Educational Resources Information Center
Sarle, Ruth; And Others
This courseware evaluation rates the "Microcomputer Applications in Vocational Education: Home Economics" program developed by the Illinois State Board of Education. (This series of programs--not contained in this document--includes interior decorating estimating, pounds away program, decision analysis, fiber care, clothing figure…
The microcomputer scientific software series 2: general linear model--regression.
Harold M. Rauscher
1983-01-01
The general linear model regression (GLMR) program provides the microcomputer user with a sophisticated regression analysis capability. The output provides a regression ANOVA table, estimators of the regression model coefficients, their confidence intervals, confidence intervals around the predicted Y-values, residuals for plotting, a check for multicollinearity, a...
Yang, Wencheng; Dong, Youhai; Hong, Yang; Guang, Qian; Chen, Xujun
2016-05-01
The study used a rabbit model to achieve anterior vertebral interbody fusion using osteogenic mesenchymal stem cells (OMSCs) transplanted in collagen sponge. We investigated the effectiveness of graft material for anterior vertebral interbody fusion using a rabbit model by examining the OMSCs transplanted in collagen sponge. Anterior vertebral interbody fusion is commonly performed. Although autogenous bone graft remains the gold-standard fusion material, it requires a separate surgical procedure and is associated with significant short-term and long-term morbidity. Recently, mesenchymal stem cells from bone marrow have been studied in various fields, including posterolateral spinal fusion. Thus, we hypothesized that cultured OMSCs transplanted in porous collagen sponge could be used successfully even in anterior vertebral interbody fusion. Forty mature male White Zealand rabbits (weight, 3.5-4.5 kg) were randomly allocated to receive one of the following graft materials: porous collagen sponge plus cultured OMSCs (group I); porous collagen sponge alone (group II); autogenous bone graft (group III); and nothing (group IV). All animals underwent anterior vertebral interbody fusion at the L4/L5 level. The lumbar spine was harvested en bloc, and the new bone formation and spinal fusion was evaluated using radiographic analysis, microcomputed tomography, manual palpation test, and histologic examination at 8 and 12 weeks after surgery. New bone formation and bony fusion was evident as early as 8 weeks in groups I and III. And there was no statistically significant difference between 8 and 12 weeks. At both time points, by microcomputed tomography and histologic analysis, new bone formation was observed in both groups I and III, fibrous tissue was observed and there was no new bone in both groups II and IV; by manual palpation test, bony fusion was observed in 40% (4/10) of rabbits in group I, 70% (7/10) of rabbits in group III, and 0% (0/10) of rabbits in both groups II and IV. These findings suggest that mesenchymal stem cells that have been cultured with osteogenic differentiation medium and loaded with collagen sponge could induce bone formation and anterior vertebral interbody fusion. And the rabbit model we developed will be useful in evaluating the effects of graft materials for anterior vertebral interbody fusion. Further study is needed to determine the most appropriate carrier for OMSCs and the feasibility in the clinical setting.
Kim, Eun-Ha; Lee, Du-Hyeong; Kwon, Sung-Min; Kwon, Tae-Yub
2017-03-01
Although new digital manufacturing techniques are attracting interest in dentistry, few studies have comprehensively investigated the marginal fit of fixed dental prostheses fabricated with such techniques. The purpose of this in vitro microcomputed tomography (μCT) study was to evaluate the marginal fit of cobalt-chromium (Co-Cr) alloy copings fabricated by casting and 3 different computer-aided design and computer-aided manufacturing (CAD-CAM)-based processing techniques and alloy systems. Single Co-Cr metal crowns were fabricated using 4 different manufacturing techniques: casting (control), milling, selective laser melting, and milling/sintering. Two different commercial alloy systems were used for each fabrication technique (a total of 8 groups; n=10 for each group). The marginal discrepancy and absolute marginal discrepancy of the crowns were determined with μCT. For each specimen, the values were determined from 4 different regions (sagittal buccal, sagittal lingual, coronal mesial, and coronal distal) by using imaging software and recorded as the average of the 4 readings. For each parameter, the results were statistically compared with 2-way analysis of variance and appropriate post hoc analysis (using Tukey or Student t test) (α=.05). The milling and selective laser melting groups showed significantly larger marginal discrepancies than the control groups (70.4 ±12.0 and 65.3 ±10.1 μm, respectively; P<.001), whereas the milling/sintering groups exhibited significantly smaller values than the controls (P=.004). The milling groups showed significantly larger absolute marginal discrepancy than the control groups (137.4 ±29.0 and 139.2 ±18.9 μm, respectively; P<.05). In the selective laser melting and milling/sintering groups, the absolute marginal discrepancy values were material-specific (P<.05). Nonetheless, the milling/sintering groups yielded statistically comparable (P=.935) or smaller (P<.001) absolute marginal discrepancies to the control groups. The findings of this in vitro μCT study showed that the marginal fit values of the Co-Cr alloy greatly depended on the fabrication methods and, occasionally, the alloy systems. Fixed dental prostheses produced by using the milling/sintering technique can be considered clinically acceptable in terms of marginal fit. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Bultreys, Tom; Boone, Marijn A.; Boone, Matthieu N.; De Schryver, Thomas; Masschaele, Bert; Van Hoorebeke, Luc; Cnudde, Veerle
2016-09-01
Over the past decade, the wide-spread implementation of laboratory-based X-ray micro-computed tomography (micro-CT) scanners has revolutionized both the experimental and numerical research on pore-scale transport in geological materials. The availability of these scanners has opened up the possibility to image a rock's pore space in 3D almost routinely to many researchers. While challenges do persist in this field, we treat the next frontier in laboratory-based micro-CT scanning: in-situ, time-resolved imaging of dynamic processes. Extremely fast (even sub-second) micro-CT imaging has become possible at synchrotron facilities over the last few years, however, the restricted accessibility of synchrotrons limits the amount of experiments which can be performed. The much smaller X-ray flux in laboratory-based systems bounds the time resolution which can be attained at these facilities. Nevertheless, progress is being made to improve the quality of measurements performed on the sub-minute time scale. We illustrate this by presenting cutting-edge pore scale experiments visualizing two-phase flow and solute transport in real-time with a lab-based environmental micro-CT set-up. To outline the current state of this young field and its relevance to pore-scale transport research, we critically examine its current bottlenecks and their possible solutions, both on the hardware and the software level. Further developments in laboratory-based, time-resolved imaging could prove greatly beneficial to our understanding of transport behavior in geological materials and to the improvement of pore-scale modeling by providing valuable validation.
Min, Yi; Ma, Jing-Zhi; Shen, Ya; Cheung, Gary Shun-Pan; Gao, Yuan
2016-11-01
The aim of this study was to investigate the clinical negotiation of various apical anatomic features of the mandibular first molars in a Chinese population using micro-computed tomography (micro-CT). A total of 152 mandibular first molars were scanned with micro-CT at 30 µm resolution. The apical 5 mm of root canal (ARC) was reconstructed three dimensionally and classified. Subsequently, the access cavity was prepared with the ARC anatomy blinded to the operator. The ARC was negotiated with a size 10 K file with or without precurve. Information on the ability to obtain a reproducible glide path was recorded. The anatomical classification of ARC was Type I with 68.45% in mandibular first molars. The negotiation result of ARC with Category i was 387 canals (74.00%). With a bent negotiating file, 96 canals were negotiated, including 88 reproducible glide paths (Category ii) and 8 irregular glide paths (Category iii). About 7.65% canals could not be negotiated with patency successfully (Category iv). The statistical analyze shown the anatomic feature of ARC had effect on the negotiation of ARC (p < 0.05). In conclusion, ARC anatomic variations had a strong potential impact on the negotiation. The category of negotiation in ARC would be helpful in the using of NiTi rotary instruments. Negotiation of ARC to the working length with patency should be careful and skillful because of the complexities of ARC. SCANNING 38:819-824, 2016. © 2016 Wiley Periodicals, Inc. © Wiley Periodicals, Inc.
Detection of marginal leakage of Class V restorations in vitro by micro-computed tomography.
Zhao, X Y; Li, S B; Gu, L J; Li, Y
2014-01-01
This in vitro study evaluated the efficacy of micro-computed tomography (CT) in marginal leakage detection of Class V restorations. Standardized Class V preparations with cervical margins in dentin and occlusal margins in enamel were made in 20 extracted human molars and restored with dental bonding agents and resin composite. All teeth were then immersed in 50% ammoniacal silver nitrate solution for 12 hours, followed by a developing solution for eight hours. Each restoration was scanned by micro-CT, the depth of marginal silver leakage in the central scanning section was measured, and the three-dimensional images of the silver leakage around each restoration were reconstructed. Afterward, all restorations were cut through the center and examined for leakage depth using a microscope. The silver leakage depth of each restoration obtained by the micro-CT and the microscope were compared for equivalency. The silver leakage depth in cervical walls observed by micro-CT and microscope showed no significant difference; however, in certain cases the judgment of leakage depth in the occlusal wall in micro-CT image was affected by adjacent enamel structure, providing less leakage depth than was observed with the microscope (p<0.01). Micro-CT displayed the three-dimensional image of the leakage around the Class V restorations with clear borders only in the dentin region. It can be concluded that micro-CT can detect nondestructively the leakage around a resin composite restoration in two and three dimensions, with accuracy comparable to that of the conventional microscope method in the dentin region but with inferior accuracy in the enamel region.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jakubowicz, J., E-mail: jaroslaw.jakubowicz@put.poznan.pl; Adamek, G.; Pałka, K.
The paper describes the formation, morphology and mechanical properties of Ti void composites. The Ti void composites were made using 100 and 325 mesh Ti powder for solid scaffold formation. The spherical and polyhedral voids (pores) were formed using saccharose particles (table sugar) of different shapes. The Ti void composite morphology was investigated by microcomputed tomography and scanning electron microscopy. The Ti void composites of designed porosity of 50–70% were made. Compression test was applied for mechanical properties estimation. It has been found, that Ti void composites made from 100 mesh Ti and those having spherical pores have a highermore » strength and elastic modulus, i.e. for the designed porosity of 50% for 100 and 325 mesh Ti void composites, a compressive strength was 32.32 and 20.13 MPa, respectively. It has been shown that this is related to better sintering of the 100 mesh Ti powders compared with the 325 mesh Ti powders. A correlation between microcomputed tomography data and mechanical properties has also been shown. The Ti void composites, made with the use of saccharose as a space holder, described in this work should be a promising material for biomedical applications, where interconnected pores and good mechanical properties are required. - Highlights: • Ti scaffolds of the porosity of 50–70% were made. • Saccharose particles as space holder were applied. • The voids in the scaffolds were designed with spherical and polyhedral shape. • The scaffold structure was investigated by SEM and micro-CT. • Micro-CT data and mechanical properties of the Ti scaffold have been correlated.« less
Zhu, Xiang-Yang; Bentley, Michael D; Chade, Alejandro R; Ritman, Erik L; Lerman, Amir; Lerman, Lilach O
2007-09-01
Changes in the structure of the artery wall commence shortly after exposure to cardiovascular risk factors, such as hypercholesterolemia (HC), but may be difficult to detect. The ability to study vascular wall structure could be helpful in evaluation of the factors that instigate atherosclerosis and its pathomechanisms. The present study tested the hypothesis that early morphological changes in coronary arteries of hypercholesterolemic (HC) pigs can be detected using the novel X-ray contrast agent OsO(4) and three-dimensional micro-computed tomography (CT). Two groups of pigs were studied after they were fed a normal or an HC (2% cholesterol) diet for 12 wk. Hearts were harvested, coronary arteries were injected with 1% OsO(4) solution, and cardiac samples (6-mum-thick) were scanned by micro-CT. Layers of the epicardial coronary artery wall, early lesions, and perivascular OsO(4) accumulation were determined. Leakage of OsO(4) from myocardial microvessels was used to assess vascular permeability, which was correlated with immunoreactivity of vascular endothelial growth factor in corresponding histological cross sections. OsO(4) enhanced the visualization of coronary artery wall layers and facilitated detection of early lesions in HC in longitudinal tomographic sections of vascular segments. Increased density of perivascular OsO(4) in HC was correlated with increased vascular endothelial growth factor expression and suggested increased microvascular permeability. The use of OsO(4) as a contrast agent in micro-CT allows three-dimensional visualization of coronary artery wall structure, early lesion formation, and changes in vascular permeability. Therefore, this technique can be a useful tool in atherosclerosis research.
Kim, Yeun; Perinpanayagam, Hiran; Lee, Jong-Ki; Yoo, Yeon-Jee; Oh, Soram; Gu, Yu; Lee, Seung-Pyo; Chang, Seok Woo; Lee, Woocheol; Baek, Seung-Ho; Zhu, Qiang; Kum, Kee-Yeon
2015-08-01
Micro-computed tomography (MCT) with alternative image reformatting techniques shows complex and detailed root canal anatomy. This study compared two-dimensional (2D) and 3D MCT image reformatting with standard tooth clearing for studying mandibular first molar mesial root canal morphology. Extracted human mandibular first molar mesial roots (n=31) were scanned by MCT (Skyscan 1172). 2D thin-slab minimum intensity projection (TS-MinIP) and 3D volume rendered images were constructed. The same teeth were then processed by clearing and staining. For each root, images obtained from clearing, 2D, 3D and combined 2D and 3D techniques were examined independently by four endodontists and categorized according to Vertucci's classification. Fine anatomical structures such as accessory canals, intercanal communications and loops were also identified. Agreement among the four techniques for Vertucci's classification was 45.2% (14/31). The most frequent were Vertucci's type IV and then type II, although many had complex configurations that were non-classifiable. Generally, complex canal systems were more clearly visible in MCT images than with standard clearing and staining. Fine anatomical structures such as intercanal communications, accessory canals and loops were mostly detected with a combination of 2D TS-MinIP and 3D volume-rendering MCT images. Canal configurations and fine anatomic structures were more clearly observed in the combined 2D and 3D MCT images than the clearing technique. The frequency of non-classifiable configurations demonstrated the complexity of mandibular first molar mesial root canal anatomy.
Mattei, Alexandra L.; Riccio, Mark L.; Avila, Frank W.; Wolfner, Mariana F.
2015-01-01
Physiological changes in females during and after mating are triggered by seminal fluid components in conjunction with female-derived molecules. In insects, these changes include increased egg production, storage of sperm, and changes in muscle contraction within the reproductive tract (RT). Such postmating changes have been studied in dissected RT tissues, but understanding their coordination in vivo requires a holistic view of the tissues and their interrelationships. Here, we used high-resolution, multiscale micro-computed tomography (CT) scans to visualize and measure postmating changes in situ in the Drosophila female RT before, during, and after mating. These studies reveal previously unidentified dynamic changes in the conformation of the female RT that occur after mating. Our results also reveal how the reproductive organs temporally shift in concert within the confines of the abdomen. For example, we observed chiral loops in the uterus and in the upper common oviduct that relax and constrict throughout sperm storage and egg movement. We found that specific seminal fluid proteins or female secretions mediate some of the postmating changes in morphology. The morphological movements, in turn, can cause further changes due to the connections among organs. In addition, we observed apparent copulatory damage to the female intima, suggesting a mechanism for entry of seminal proteins, or other exogenous components, into the female’s circulatory system. The 3D reconstructions provided by high-resolution micro-CT scans reveal how male and female molecules and anatomy interface to carry out and coordinate mating-dependent changes in the female’s reproductive physiology. PMID:26041806
Sombke, Andy; Lipke, Elisabeth; Michalik, Peter; Uhl, Gabriele; Harzsch, Steffen
2015-01-01
Classical histology or immunohistochemistry combined with fluorescence or confocal laser scanning microscopy are common techniques in arthropod neuroanatomy, and these methods often require time-consuming and difficult dissections and sample preparations. Moreover, these methods are prone to artifacts due to compression and distortion of tissues, which often result in information loss and especially affect the spatial relationships of the examined parts of the nervous system in their natural anatomical context. Noninvasive approaches such as X-ray micro-computed tomography (micro-CT) can overcome such limitations and have been shown to be a valuable tool for understanding and visualizing internal anatomy and structural complexity. Nevertheless, knowledge about the potential of this method for analyzing the anatomy and organization of nervous systems, especially of taxa with smaller body size (e.g., many arthropods), is limited. This study set out to analyze the brains of selected arthropods with micro-CT, and to compare these results with available histological and immunohistochemical data. Specifically, we explored the influence of different sample preparation procedures. Our study shows that micro-CT is highly suitable for analyzing arthropod neuroarchitecture in situ and allows specific neuropils to be distinguished within the brain to extract quantitative data such as neuropil volumes. Moreover, data acquisition is considerably faster compared with many classical histological techniques. Thus, we conclude that micro-CT is highly suitable for targeting neuroanatomy, as it reduces the risk of artifacts and is faster than classical techniques. J. Comp. Neurol. 523:1281–1295, 2015. © 2015 Wiley Periodicals, Inc. PMID:25728683
Evaluation of a new mid-scala cochlear implant electrode using microcomputed tomography.
Frisch, Christopher D; Carlson, Matthew L; Lane, John I; Driscoll, Colin L W
2015-12-01
To investigate electrode position, depth of insertion, and electrode contact using an electrode array with a mid-scala design following round window (RW) and cochleostomy insertion. Eight fresh-frozen cadaveric bones were implanted; half via a RW approach and half through an anteroinferior cochleostomy using a styleted mid-scala electrode design. Microcomputed tomography was used to acquire oblique coronal and oblique axial reformations. Individual electrode positions along each array, insertional depth, and electrode contact were determined using National Institutes of Health Image J software. All electrodes were inserted without significant resistance. The average angular depth of insertion was 436.5° for the RW group and 422.7° for the cochleostomy group. All electrodes acquired a perimodiolar position in the proximal segment and a lateral wall position at the basal turn, regardless of approach. Electrodes distal to the basal turn demonstrated a variable location, with 78% mid scala. One cochleostomy array fractured through the interscalar partition (ISP), acquiring a scala vestibuli position. The odds ratio for either abutting the modiolus, ISP, lateral wall or floor, or fracturing through the ISP were 2.7 times more likely following a cochleostomy insertion (P = .032). The styleted mid-scala electrode design acquires a proximal perimodiolar position, a lateral wall location, as it traverses the basal turn, and most commonly a mid-scala position in the distal array. Interscalar excursion occurred in one of the cochleostomy insertions. Cochleostomy insertion is more likely to result in ultimate final electrode position adjacent to critical intracochlear structures. NA. © 2015 The American Laryngological, Rhinological and Otological Society, Inc.
Fernández, Rosa; Kvist, Sebastian; Lenihan, Jennifer; Giribet, Gonzalo; Ziegler, Alexander
2014-01-01
In spite of the high relevance of lumbricid earthworms ('Oligochaeta': Lumbricidae) for soil structure and functioning, the taxonomy of this group of terrestrial invertebrates remains in a quasi-chaotic state. Earthworm taxonomy traditionally relies on the interpretation of external and internal morphological characters, but the acquisition of these data is often hampered by tedious dissections or restricted access to valuable and rare museum specimens. The present state of affairs, in conjunction with the difficulty of establishing primary homologies for multiple morphological features, has led to an almost unrivaled instability in the taxonomy and systematics of certain earthworm groups, including Lumbricidae. As a potential remedy, we apply for the first time a non-destructive imaging technique to lumbricids and explore the future application of this approach to earthworm taxonomy. High-resolution micro-computed tomography (μCT) scanning of freshly fixed and museum specimens was carried out using two cosmopolitan species, Aporrectodea caliginosa and A. trapezoides. By combining two-dimensional and three-dimensional dataset visualization techniques, we demonstrate that the morphological features commonly used in earthworm taxonomy can now be analyzed without the need for dissection, whether freshly fixed or museum specimens collected more than 60 years ago are studied. Our analyses show that μCT in combination with soft tissue staining can be successfully applied to lumbricid earthworms. An extension of the approach to other families is poised to strengthen earthworm taxonomy by providing a versatile tool to resolve the taxonomic chaos currently present in this ecologically important, but taxonomically neglected group of terrestrial invertebrates.
Fernández, Rosa; Kvist, Sebastian; Lenihan, Jennifer; Giribet, Gonzalo; Ziegler, Alexander
2014-01-01
In spite of the high relevance of lumbricid earthworms (‘Oligochaeta’: Lumbricidae) for soil structure and functioning, the taxonomy of this group of terrestrial invertebrates remains in a quasi-chaotic state. Earthworm taxonomy traditionally relies on the interpretation of external and internal morphological characters, but the acquisition of these data is often hampered by tedious dissections or restricted access to valuable and rare museum specimens. The present state of affairs, in conjunction with the difficulty of establishing primary homologies for multiple morphological features, has led to an almost unrivaled instability in the taxonomy and systematics of certain earthworm groups, including Lumbricidae. As a potential remedy, we apply for the first time a non-destructive imaging technique to lumbricids and explore the future application of this approach to earthworm taxonomy. High-resolution micro-computed tomography (μCT) scanning of freshly fixed and museum specimens was carried out using two cosmopolitan species, Aporrectodea caliginosa and A. trapezoides. By combining two-dimensional and three-dimensional dataset visualization techniques, we demonstrate that the morphological features commonly used in earthworm taxonomy can now be analyzed without the need for dissection, whether freshly fixed or museum specimens collected more than 60 years ago are studied. Our analyses show that μCT in combination with soft tissue staining can be successfully applied to lumbricid earthworms. An extension of the approach to other families is poised to strengthen earthworm taxonomy by providing a versatile tool to resolve the taxonomic chaos currently present in this ecologically important, but taxonomically neglected group of terrestrial invertebrates. PMID:24837238
Notch3 as a novel therapeutic target in metastatic medullary thyroid cancer.
Lou, Irene; Odorico, Scott; Yu, Xiao-Min; Harrison, April; Jaskula-Sztul, Renata; Chen, Herbert
2018-01-01
Medullary thyroid cancer portends poor survival once liver metastasis occurs. We hypothesize that Notch3 overexpression in medullary thyroid cancer liver metastasis will decrease proliferation and growth of the tumor. TT cells were modified genetically to overexpress Notch3 in the presence of doxycycline, creating the TT-Notch3 cell line. Mice were injected intrasplenically with either TT-Notch3 or control vector TT-TRE cells. Each cell line had 3 treatment groups: control with 12 weeks of standard chow, early DOX with doxycycline chow at day 0 and for 70 days thereafter, and late DOX with doxycycline chow at 8 weeks. Each animal underwent micro-computed tomography to evaluate for tumor formation and tumor quantification was performed. Animals were killed at 12 weeks, and the harvested liver was stained with Ki-67, hematoxylin and eosin, and Notch3. Induction of Notch3 did not prevent formation of medullary thyroid cancer liver metastases as all mice in the early DOX group developed tumors. However, induction of Notch after medullary thyroid cancer liver tumor formation decreased tumor size, as seen on micro-computed tomography scans (late DOX group). This translated to a 37-fold decrease in tumor volume (P = .001). Notch3 overexpression also resulted in decreased Ki-67 index (P = .038). Moreover, Notch3 induction led to increased areas of neutrophil infiltration and necrosis on hematoxylin and eosin staining of the tumors CONCLUSION: Notch3 overexpression demonstrates an antiproliferative effect on established metastatic medullary thyroid cancer liver tumors and is a potential therapeutic target in treatment. Copyright © 2017 Elsevier Inc. All rights reserved.
Shibata, T; Komatsu, K; Shimada, A; Shimoda, S; Oida, S; Kawasaki, K; Chiba, M
2004-12-01
We examined the effect of the pretreatment of roots with alendronate on the restoration of the support function of the healing periodontal ligament in replanted rat molars. The left maxillary first molars were extracted, placed in 0.9% NaCl containing 1 mm alendronate (alendronate group) or 0.9% NaCl (control group) for 5 min, and were replanted into their sockets. Groups of animals were killed at 7, 14, and 21 days after replantation. Normal control rats were also killed on the same days. The force required to extract the replanted or normal tooth from its socket was measured, and a load-deformation curve was developed and analyzed. Micro-computed tomography and histologic analyses were also made. The mechanical properties of the healing periodontal ligament in the alendronate group were gradually restored from 7 to 21 days. However, fractures of the roots and bones during mechanical testing occurred in most of the replanted teeth in the control group at 21 days. The rates of restoration of the mechanical strength, extensibility, stiffness, and toughness for the alendronate group at 21 days were 67, 98, 74, and 68% of the normal controls, respectively. Micro-computed tomography and histologic observations revealed that bone-like structures within the pulp and ankylosis between the roots and socket bones occurred commonly in the control group, but were uncommon in the alendronate group. Our findings suggest that the pretreatment with alendronate inhibits the formation of abnormal mineralized tissues and results in better restoration of the support function of the healing periodontal ligament in replanted teeth. (c)Blackwell Munksgaard 2004
Microcomputer spacecraft thermal analysis routines (MSTAR) Phase I: The user interface
DOE Office of Scientific and Technical Information (OSTI.GOV)
Teti, N.M.
1993-12-31
The Microcomputer Spacecraft Thermal Analysis Routines (MSTAR) software package is being developed for NASA/Goddard Space Flight Center by Swales and Associates, Inc. (S&AI). In December 1992, S&AI was awarded a phase I Small Business Inovative Research contract fronm NASA to develop a microcomputer based thermal analysis program to replace the current SSPTA and TRASYS programs. Phase I consists of a six month effort which will focus on developing geometric model generation and visualization capabilities using a graphical user interface (GUI). The information contained in this paper encompasses the work performed during the Phase I development cycle; with emphasis on themore » development of the graphical user interface (GUI). This includes both the theory behind and specific examples of how the MSTAR GUI was implemented. Furthermore, this report discusses new applications and enhancements which will improve the capabilities and commercialization of the MSTAR program.« less
Microcomputer spacecraft thermal analysis routines (MSTAR) Phase I: The user interface
NASA Technical Reports Server (NTRS)
Teti, Nicholas M.
1993-01-01
The Microcomputer Spacecraft Thermal Analysis Routines (MSTAR) software package is being developed for NASA/Goddard Space Flight Center by Swales and Associates, Inc. (S&AI). In December 1992, S&AI was awarded a phase I Small Business Inovative Research contract fronm NASA to develop a microcomputer based thermal analysis program to replace the current SSPTA and TRASYS programs. Phase I consists of a six month effort which will focus on developing geometric model generation and visualization capabilities using a graphical user interface (GUI). The information contained in this paper encompasses the work performed during the Phase I development cycle; with emphasis on the development of the graphical user interface (GUI). This includes both the theory behind and specific examples of how the MSTAR GUI was implemented. Furthermore, this report discusses new applications and enhancements which will improve the capabilities and commercialization of the MSTAR program.
NASA Technical Reports Server (NTRS)
Faust, N.; Jordon, L.
1981-01-01
Since the implementation of the GRID and IMGRID computer programs for multivariate spatial analysis in the early 1970's, geographic data analysis subsequently moved from large computers to minicomputers and now to microcomputers with radical reduction in the costs associated with planning analyses. Programs designed to process LANDSAT data to be used as one element in a geographic data base were used once NIMGRID (new IMGRID), a raster oriented geographic information system, was implemented on the microcomputer. Programs for training field selection, supervised and unsupervised classification, and image enhancement were added. Enhancements to the color graphics capabilities of the microsystem allow display of three channels of LANDSAT data in color infrared format. The basic microcomputer hardware needed to perform NIMGRID and most LANDSAT analyses is listed as well as the software available for LANDSAT processing.
The dynamic micro computed tomography at SSRF
NASA Astrophysics Data System (ADS)
Chen, R.; Xu, L.; Du, G.; Deng, B.; Xie, H.; Xiao, T.
2018-05-01
Synchrotron radiation micro-computed tomography (SR-μCT) is a critical technique for quantitative characterizing the 3D internal structure of samples, recently the dynamic SR-μCT has been attracting vast attention since it can evaluate the three-dimensional structure evolution of a sample. A dynamic μCT method, which is based on monochromatic beam, was developed at the X-ray Imaging and Biomedical Application Beamline at Shanghai Synchrotron Radiation Facility, by combining the compressed sensing based CT reconstruction algorithm and hardware upgrade. The monochromatic beam based method can achieve quantitative information, and lower dose than the white beam base method in which the lower energy beam is absorbed by the sample rather than contribute to the final imaging signal. The developed method is successfully used to investigate the compression of the air sac during respiration in a bell cricket, providing new knowledge for further research on the insect respiratory system.
NASA Astrophysics Data System (ADS)
Pankhurst, M. J.; Fowler, R.; Courtois, L.; Nonni, S.; Zuddas, F.; Atwood, R. C.; Davis, G. R.; Lee, P. D.
2018-01-01
We present new software allowing significantly improved quantitative mapping of the three-dimensional density distribution of objects using laboratory source polychromatic X-rays via a beam characterisation approach (c.f. filtering or comparison to phantoms). One key advantage is that a precise representation of the specimen material is not required. The method exploits well-established, widely available, non-destructive and increasingly accessible laboratory-source X-ray tomography. Beam characterisation is performed in two stages: (1) projection data are collected through a range of known materials utilising a novel hardware design integrated into the rotation stage; and (2) a Python code optimises a spectral response model of the system. We provide hardware designs for use with a rotation stage able to be tilted, yet the concept is easily adaptable to virtually any laboratory system and sample, and implicitly corrects the image artefact known as beam hardening.
Smith, Emma L.; Roberts, Carol A.
2012-01-01
Understanding the structural development of embryonic bone in a three dimensional framework is fundamental to developing new strategies for the recapitulation of bone tissue in latter life. We present an innovative combined approach of an organotypic embryonic femur culture model, microcomputed tomography (μCT) and immunohistochemistry to examine the development and modulation of the three dimensional structures of the developing embryonic femur. Isolated embryonic chick femurs were organotypic (air/liquid interface) cultured for 10 days in either basal, chondrogenic, or osteogenic supplemented culture conditions. The growth development and modulating effects of basal, chondrogenic, or osteogenic culture media of the embryonic chick femurs was investigated using μCT, immunohistochemistry, and histology. The growth and development of noncultured embryonic chick femur stages E10, E11, E12, E13, E15, and E17 were very closely correlated with increased morphometric indices of bone formation as determined by μCT. After 10 days in the organotpyic culture set up, the early aged femurs (E10 and E11) demonstrated a dramatic response to the chondrogenic or osteogenic culture conditions compared to the basal cultured femurs as determined by a change in μCT morphometric indices and modified expression of chondrogenic and osteogenic markers. Although the later aged femurs (E12 and E13) increased in size and structure after 10 days organotpypic culture, the effects of the osteogenic and chondrogenic organotypic cultures on these femurs were not significantly altered compared to basal conditions. We have demonstrated that the embryonic chick femur organotpyic culture model combined with the μCT and immunohistochemical analysis can provide an integral methodology for investigating the modulation of bone development in an ex vivo culture setting. Hence, these interdisciplinary techniques of μCT and whole organ bone cultures will enable us to delineate some of the temporal, structural developmental paradigms and modulation of bone tissue formation to underpin innovative skeletal regenerative technology for clinical therapeutic strategies in musculoskeletal trauma and diseases. PMID:22472170
NASA Astrophysics Data System (ADS)
Titschack, J.; Baum, D.; Matsuyama, K.; Boos, K.; Färber, C.; Kahl, W.-A.; Ehrig, K.; Meinel, D.; Soriano, C.; Stock, S. R.
2018-06-01
During the last decades, X-ray (micro-)computed tomography has gained increasing attention for the description of porous skeletal and shell structures of various organism groups. However, their quantitative analysis is often hampered by the difficulty to discriminate cavities and pores within the object from the surrounding region. Herein, we test the ambient occlusion (AO) algorithm and newly implemented optimisations for the segmentation of cavities (implemented in the software Amira). The segmentation accuracy is evaluated as a function of (i) changes in the ray length input variable, and (ii) the usage of AO (scalar) field and other AO-derived (scalar) fields. The results clearly indicate that the AO field itself outperforms all other AO-derived fields in terms of segmentation accuracy and robustness against variations in the ray length input variable. The newly implemented optimisations improved the AO field-based segmentation only slightly, while the segmentations based on the AO-derived fields improved considerably. Additionally, we evaluated the potential of the AO field and AO-derived fields for the separation and classification of cavities as well as skeletal structures by comparing them with commonly used distance-map-based segmentations. For this, we tested the zooid separation within a bryozoan colony, the stereom classification of an ophiuroid tooth, the separation of bioerosion traces within a marble block and the calice (central cavity)-pore separation within a dendrophyllid coral. The obtained results clearly indicate that the ideal input field depends on the three-dimensional morphology of the object of interest. The segmentations based on the AO-derived fields often provided cavity separations and skeleton classifications that were superior to or impossible to obtain with commonly used distance-map-based segmentations. The combined usage of various AO-derived fields by supervised or unsupervised segmentation algorithms might provide a promising target for future research to further improve the results for this kind of high-end data segmentation and classification. Furthermore, the application of the developed segmentation algorithm is not restricted to X-ray (micro-)computed tomographic data but may potentially be useful for the segmentation of 3D volume data from other sources.
Dong, Jingjing; Cui, Geng; Bi, Long; Li, Jie; Lei, Wei
2013-01-01
In order to improve the mechanical and biological properties of calcium phosphate cement (CPC, nanometer-biomaterial) for bone reconstruction in the rabbit femoral defect model, fibrin glue (FG, the natural product, purified from the blood) was introduced at three different ratios. The CPC powder and the FG solution were mixed, respectively, at the powder/liquid (P/L) ratios (g/mL) of 1:1, 3:1, and 5:1 (g/mL), and pure CPC was used as a control. After being implanted into the femoral defect in rabbit, the healing process was evaluated by micro-computed tomography scan, biomechanical testing, and histological examination. By micro-computed tomography analysis, the P/L ratio of 1:1 (g/mL) group indicated the largest quantity of new bone formation at 4 weeks, 8 weeks, and 12 weeks after implantation, respectively. Bone volume per trabecular volume of the 1:1 group was highest in the four groups, which was 1.45% ± 0.42%, 7.35% ± 1.45%, and 29.10% ± 1.67% at 4 weeks, 8 weeks, and 12 weeks after the operation, respectively. In the biomechanical tests, the compressive strength and the elastic modulus of the three CPC–FG groups were much higher than those of the pure CPC group at the determined time point (P < 0.05). The histological evaluation also showed the best osseointegration in the 1:1 group at 4 weeks, 8 weeks, and 12 weeks after the operation, respectively. In the 1:1 group, the bone grew into the pore of the cement in the laminar arrangement and connected with the cement tightly at the 12th week after the operation. This present study indicated that the CPC–FG composite at the P/L ratio of 1:1 (g/mL) stimulated bone regeneration better than any other designed group, which suggested that CPC–FG at the P/L ratio of 1:1 has significant potential as the bioactive material for the treatment of bone defects. PMID:23576869
ERIC Educational Resources Information Center
Soddell, J. A.; Seviour, R. J.
1985-01-01
Describes an exercise which uses a computer program (written for Commodore 64 microcomputers) that accepts data obtained from identifying bacteria, calculates similarity coefficients, and performs single linkage cluster analysis. Includes a program for simulating bacterial cultures for students who should not handle pathogenic microorganisms. (JN)
ERIC Educational Resources Information Center
Russell, David W.; Lucas, Keith B.; McRobbie, Campbell J.
2003-01-01
Investigates how microcomputer-based laboratory (MBL) activities specifically designed to be consistent with a constructivist theory of learning support or constrain student construction of understanding. Analysis of students' discourse and actions reveal that students invented numerous techniques for manipulating data in the service of their…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cil, Mehmet B.; Alshibli, Khalid A.; Kenesei, Peter
3D synchrotron X-ray diffraction (3DXRD) and synchrotron micro-computed tomography (SMT) techniques were used to measure and monitor the lattice strain evolution and fracture behavior of natural Ottawa sand particles subjected to 1D compression loading. The particle-averaged lattice strain within sand particles was measured using 3DXRD and then was used to calculate the corresponding lattice stress tensor. In addition, the evolution and mode of fracture of sand particles was investigated using high-resolution 3D SMT images. The results of diffraction data analyses revealed that the major principal component of the lattice strain or stress tensor increased in most of the particles asmore » the global applied compressive load increased until the onset of fracture. Particle fracture and subsequent rearrangements caused significant variation and fluctuations in measured lattice strain/stress values from one particle to another and from one load step to the next one. SMT image analysis at the particle-scale showed that cracks in fractured sand particles generally initiate and propagate along the plane that connects the two contact points. Fractured particles initially split into two or three major fragments followed by disintegration into multiple smaller fragments in some cases. In conclusion, microscale analysis of fractured particles showed that particle position, morphology, the number and location of contact points play a major role in the occurrence of particle fracture in confined comminution of the sand assembly.« less
Cil, Mehmet B.; Alshibli, Khalid A.; Kenesei, Peter
2017-05-27
3D synchrotron X-ray diffraction (3DXRD) and synchrotron micro-computed tomography (SMT) techniques were used to measure and monitor the lattice strain evolution and fracture behavior of natural Ottawa sand particles subjected to 1D compression loading. The particle-averaged lattice strain within sand particles was measured using 3DXRD and then was used to calculate the corresponding lattice stress tensor. In addition, the evolution and mode of fracture of sand particles was investigated using high-resolution 3D SMT images. The results of diffraction data analyses revealed that the major principal component of the lattice strain or stress tensor increased in most of the particles asmore » the global applied compressive load increased until the onset of fracture. Particle fracture and subsequent rearrangements caused significant variation and fluctuations in measured lattice strain/stress values from one particle to another and from one load step to the next one. SMT image analysis at the particle-scale showed that cracks in fractured sand particles generally initiate and propagate along the plane that connects the two contact points. Fractured particles initially split into two or three major fragments followed by disintegration into multiple smaller fragments in some cases. In conclusion, microscale analysis of fractured particles showed that particle position, morphology, the number and location of contact points play a major role in the occurrence of particle fracture in confined comminution of the sand assembly.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, T.F.; Gerhard, M.A.; Trummer, D.J.
CASKS (Computer Analysis of Storage casKS) is a microcomputer-based system of computer programs and databases developed at the Lawrence Livermore National Laboratory (LLNL) for evaluating safety analysis reports on spent-fuel storage casks. The bulk of the complete program and this user`s manual are based upon the SCANS (Shipping Cask ANalysis System) program previously developed at LLNL. A number of enhancements and improvements were added to the original SCANS program to meet requirements unique to storage casks. CASKS is an easy-to-use system that calculates global response of storage casks to impact loads, pressure loads and thermal conditions. This provides reviewers withmore » a tool for an independent check on analyses submitted by licensees. CASKS is based on microcomputers compatible with the IBM-PC family of computers. The system is composed of a series of menus, input programs, cask analysis programs, and output display programs. All data is entered through fill-in-the-blank input screens that contain descriptive data requests.« less
Acar, Buket; Kamburoğlu, Kıvanç; Tatar, İlkan; Arıkan, Volkan; Çelik, Hakan Hamdi; Yüksel, Selcen; Özen, Tuncer
2015-12-01
This study was performed to compare the accuracy of micro-computed tomography (CT) and cone-beam computed tomography (CBCT) in detecting accessory canals in primary molars. Forty-one extracted human primary first and second molars were embedded in wax blocks and scanned using micro-CT and CBCT. After the images were taken, the samples were processed using a clearing technique and examined under a stereomicroscope in order to establish the gold standard for this study. The specimens were classified into three groups: maxillary molars, mandibular molars with three canals, and mandibular molars with four canals. Differences between the gold standard and the observations made using the imaging methods were calculated using Spearman's rho correlation coefficient test. The presence of accessory canals in micro-CT images of maxillary and mandibular root canals showed a statistically significant correlation with the stereomicroscopic images used as a gold standard. No statistically significant correlation was found between the CBCT findings and the stereomicroscopic images. Although micro-CT is not suitable for clinical use, it provides more detailed information about minor anatomical structures. However, CBCT is convenient for clinical use but may not be capable of adequately analyzing the internal anatomy of primary teeth.
Two Flat-Backed Polydesmidan Millipedes from the Miocene Chiapas-Amber Lagerstätte, Mexico
Riquelme, Francisco; Hernández-Patricio, Miguel; Martínez-Dávalos, Arnulfo; Rodríguez-Villafuerte, Mercedes; Montejo-Cruz, Maira; Alvarado-Ortega, Jesús; Ruvalcaba-Sil, José L.; Zúñiga-Mijangos, Luis
2014-01-01
Two species of fossil polydesmidan millipedes (Diplopoda: Polydesmida) embedded in amber are described from Miocene strata near Simojovel, in the Chiapas Highlands, Mexico. Maatidesmus paachtun gen. et sp. nov., placed into Chelodesmidae Cook, 1895, and Anbarrhacus adamantis gen. et sp. nov., assigned in the family Platyrhacidae Pocock, 1895. Morphological data from fossil specimens have been recovered using 3D X-ray micro-computed tomography and regular to infrared-reflected microscopy. Both fossil species are recognizable as new primarily but not exclusively, by collum margin modification and remarkable paranotal and metatergite dorsal sculpture. PMID:25162220
Two flat-backed polydesmidan millipedes from the Miocene Chiapas-amber Lagerstätte, Mexico.
Riquelme, Francisco; Hernández-Patricio, Miguel; Martínez-Dávalos, Arnulfo; Rodríguez-Villafuerte, Mercedes; Montejo-Cruz, Maira; Alvarado-Ortega, Jesús; Ruvalcaba-Sil, José L; Zúñiga-Mijangos, Luis
2014-01-01
Two species of fossil polydesmidan millipedes (Diplopoda: Polydesmida) embedded in amber are described from Miocene strata near Simojovel, in the Chiapas Highlands, Mexico. Maatidesmus paachtun gen. et sp. nov., placed into Chelodesmidae Cook, 1895, and Anbarrhacus adamantis gen. et sp. nov., assigned in the family Platyrhacidae Pocock, 1895. Morphological data from fossil specimens have been recovered using 3D X-ray micro-computed tomography and regular to infrared-reflected microscopy. Both fossil species are recognizable as new primarily but not exclusively, by collum margin modification and remarkable paranotal and metatergite dorsal sculpture.
3D analysis of bone formation around titanium implants using micro-computed tomography (μCT)
NASA Astrophysics Data System (ADS)
Bernhardt, Ricardo; Scharnweber, Dieter; Müller, Bert; Beckmann, Felix; Goebbels, Jürgen; Jansen, John; Schliephake, Henning; Worch, Hartmut
2006-08-01
The quantitative analysis of bone formation around biofunctionalised metallic implants is an important tool for the further development of implants with higher success rates. This is, nowadays, especially important in cases of additional diseases like diabetes or osteoporosis. Micro computed tomography (μCT), as non-destructive technique, offers the possibility for quantitative three-dimensional recording of bone close to the implant's surface with micrometer resolution, which is the range of the relevant bony structures. Within different animal models using cylindrical and screw-shaped Ti6Al4V implants we have compared visualization and quantitative analysis of newly formed bone by the use of synchrotron-radiation-based CT-systems in comparison with histological findings. The SRμCT experiments were performed at the beamline BW 5 (HASYLAB at DESY, Hamburg, Germany; at the BAMline (BESSY, Berlin, Germany). For the experiments, PMMA-embedded samples were prepared with diameters of about 8 mm, which contain in the center the implant surrounded by the bony tissue. To (locally) quantify the bone formation, models were developed and optimized. The comparison of the results obtained by SRμCT and histology demonstrates the advantages and disadvantages of both approaches, although the bone formation values for the different biofunctionalized implants are identical within the error bars. SRμCT allows the clear identification of fully mineralized bone around the different titanium implants. As hundreds of virtual slices were easily generated for the individual samples, the quantification and interactive bone detection led to conclusions of high precision and statistical relevance. In this way, SRμCT in combination with interactive data analysis is proven to be more significant with respect to classical histology.
Geometrical characterization of perlite-metal syntactic foam
DOE Office of Scientific and Technical Information (OSTI.GOV)
Borovinšek, Matej, E-mail: matej.borovinsek@um.si
This paper introduces an improved method for the detailed geometrical characterization of perlite-metal syntactic foam. This novel metallic foam is created by infiltrating a packed bed of expanded perlite particles with liquid aluminium alloy. The geometry of the solidified metal is thus defined by the perlite particle shape, size and morphology. The method is based on a segmented micro-computed tomography data and allows for automated determination of the distributions of pore size, sphericity, orientation and location. The pore (i.e. particle) size distribution and pore orientation is determined by a multi-criteria k-nearest neighbour algorithm for pore identification. The results indicate amore » weak density gradient parallel to the casting direction and a slight preference of particle orientation perpendicular to the casting direction. - Highlights: •A new method for identification of pores in porous materials was developed. •It was applied on perlite-metal syntactic foam samples. •A porosity decrease in the axial direction of the samples was determined. •Pore shape analysis showed a high percentage of spherical pores. •Orientation analysis showed that more pores are oriented in the radial direction.« less
NASA Astrophysics Data System (ADS)
Kuo, Yi-Jie; Huang, Yung-Kai; Chou, Hsiu-Chu; Pai, Man-Hui; Lee, Ai-Wei; Mai, Fu-Der; Chang, Hung-Ming
2015-08-01
Teeth are the hardest tissue in the body. The growth of teeth is closely regulated by circadian rhythmicity. Considering that sleep deprivation (SD) is a severe condition that disrupts normal circadian rhythmicity, this study was conducted to determine whether calcium expression (the major element participating in teeth constitution), and dental mass would be significantly impaired following SD. Adolescent rats subjected to 3 weeks of SD were processed for energy dispersive spectrum (EDS), time-of-flight secondary ion mass spectrometry (TOF-SIMS), and micro-computed tomography (micro-CT) analyses. The EDS and TOF-SIMS results indicated that high calcium intensity was detected in both the upper and lower incisors of untreated rats. Micro-CT analysis corresponded closely with spectral data in which an enhanced dental mass was calculated in intact animals. However, following SD, both calcium expression and the dental mass were remarkably decreased to nearly half those of the untreated values. Because SD plays a detrimental role in impairing dental structure, establishing satisfactory sleep behavior would therefore serve as a crucial strategy for preventing or improving prevalent dental dysfunctions.
Computers in Louisiana Public Schools: A Trend Analysis, 1980-1990.
ERIC Educational Resources Information Center
Jordan, Daniel W.
A survey instrument was developed to determine the status of microcomputers in the public schools of Louisiana. The instrument solicited information concerning the number of microcomputers in the schools, the manufacturers of the computers, and how the computers were being used in the school system. The survey was mailed to 66 districts in the…
Microcomputers in Schools, 1984-85. A Comprehensive Survey and Analysis.
ERIC Educational Resources Information Center
Hood, John F.; And Others
This report of Market Data Retrieval's second comprehensive survey of microcomputers and their use in grades K-12 presents information for the 1984-85 year for public, private, and Catholic schools in the United States. The survey findings are summarized in a brief introduction, and detailed data are presented in the 37 tables and 9 maps that…
ERIC Educational Resources Information Center
Canelos, James; And Others
This study examined the effects of two cognitive styles--field dependents-independents and reflectivity-impulsivity--on learning from microcomputer-based instruction. In the first of three experimental designs, a programmed instruction text on the human heart was used which contained both visual and verbal information in an instructional display,…
Microcomputer software for calculating the western Oregon elk habitat effectiveness index.
Alan Ager; Mark Hitchcock
1992-01-01
This paper describes the operation of the microcomputer program HEIWEST, which was developed to automate calculation of the western Oregon elk habitat effectiveness index (HEI). HEIWEST requires little or no training to operate and vastly simplifies the task of measuring HEI for either site-specific project analysis or long-term monitoring of elk habitat. It is...
Keleş, A; Keskin, C
2018-02-01
To conduct a quantitative and qualitative analysis of the band-shaped isthmus area, the floor of which was in the apical third in the mesial roots of mandibular first molars using micro-computed tomography (micro-CT). Micro-CT images of 269 mesial roots of mandibular first molars were evaluated, and 40 specimens with a band-shaped isthmus, with a floor in the apical third, were selected. The major diameter, minor diameter, roundness, area and perimeter values for the most coronal and apical slices where the isthmus was visible were measured. The distances between these slices were measured as the isthmus length, and the total volume, structure model index and surface area of the isthmus were measured. The distances between the isthmus floor and two apical foramina and the number of root canal orifices were calculated. The dimensions of the isthmus roof and the floor were compared, and the data were analysed using descriptive statistics and Student's t-tests with a significance threshold set at 5%. A total of 15% of the specimens had band-shaped isthmuses with a floor in the apical third. The isthmus roof exhibited significantly greater major and minor diameter values compared to the isthmus floor (P < 0.05). No significant difference was detected between the isthmus roof and the floor with regard to roundness (P > 0.05). Three- and two-dimensional analyses of the mesial roots of mandibular molars revealed that band-shaped isthmuses had complex shapes. © 2017 International Endodontic Journal. Published by John Wiley & Sons Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bhatti, A.A.
1990-04-01
This paper examines the effects of primary and secondary fault quantities as well s of mutual couplings of neighboring circuits on the sensitivity of operation and threshold settings of a microcomputer based differential protection of UHV lines under selective phase switching. Microcomputer based selective phase switching allows the disconnection of minimum number of phases involved in a fault and requires the autoreclosing of these phases immediately after the extinction of secondary arc. During a primary fault a heavy current contribution to the healthy phases tends to cause an unwanted tripping. Faulty phases physically disconnected constitute an isolated fault which beingmore » coupled to the system affects the current and voltage levels of the healthy phases still retained in the system and may cause an unwanted tripping. The microcomputer based differential protection, appears to have poor performance when applied to uncompensated lines employing selective pole switching.« less
Structure and properties of clinical coralline implants measured via 3D imaging and analysis.
Knackstedt, Mark Alexander; Arns, Christoph H; Senden, Tim J; Gross, Karlis
2006-05-01
The development and design of advanced porous materials for biomedical applications requires a thorough understanding of how material structure impacts on mechanical and transport properties. This paper illustrates a 3D imaging and analysis study of two clinically proven coral bone graft samples (Porites and Goniopora). Images are obtained from X-ray micro-computed tomography (micro-CT) at a resolution of 16.8 microm. A visual comparison of the two images shows very different structure; Porites has a homogeneous structure and consistent pore size while Goniopora has a bimodal pore size and a strongly disordered structure. A number of 3D structural characteristics are measured directly on the images including pore volume-to-surface-area, pore and solid size distributions, chord length measurements and tortuosity. Computational results made directly on the digitized tomographic images are presented for the permeability, diffusivity and elastic modulus of the coral samples. The results allow one to quantify differences between the two samples. 3D digital analysis can provide a more thorough assessment of biomaterial structure including the pore wall thickness, local flow, mechanical properties and diffusion pathways. We discuss the implications of these results to the development of optimal scaffold design for tissue ingrowth.
MicroCT angiography detects vascular formation and regression in skin wound healing
Urao, Norifumi; Okonkwo, Uzoagu A.; Fang, Milie M.; Zhuang, Zhen W.; Koh, Timothy J.; DiPietro, Luisa A.
2016-01-01
Properly regulated angiogenesis and arteriogenesis are essential for effective wound healing. Tissue injury induces robust new vessel formation and subsequent vessel maturation, which involves vessel regression and remodeling. Although formation of functional vasculature is essential for healing, alterations in vascular structure over the time course of skin wound healing are not well understood. Here, using high-resolution ex vivo X-ray micro-computed tomography (microCT), we describe the vascular network during healing of skin excisional wounds with highly detailed three-dimensional (3D) reconstructed images and associated quantitative analysis. We found that relative vessel volume, surface area and branching number are significantly decreased in wounds from day 7 to day 14 and 21. Segmentation and skeletonization analysis of selected branches from high-resolution images as small as 2.5 μm voxel size show that branching orders are decreased in the wound vessels during healing. In histological analysis, we found that the contrast agent fills mainly arterioles, but not small capillaries nor large veins. In summary, high-resolution microCT revealed dynamic alterations of vessel structures during wound healing. This technique may be useful as a key tool in the study of the formation and regression of wound vessels. PMID:27009591
ERIC Educational Resources Information Center
Stuck, M. F.
This guide provides an introduction to the use of microcomputers with qualitative data. It is deliberately non-specific and rudimentary in order to be of maximum benefit to the widest possible audience of beginning microcomputer users who wish to analyze their data using software that is not specifically designed for qualitative data analysis. The…
Pilot of a System for Collecting Daily Classroom Data on Learning by Using Microcomputers.
ERIC Educational Resources Information Center
Mayer, Victor J.; Raudebaugh, William
This report describes a microcomputer system which collects data from students in classrooms on a daily basis and is then used to evaluate concept achievement and attitude changes through a time series analysis. Two pilot studies in two junior high schools in Ohio are detailed, where eighth grade students' progress in an earth science study unit…
Goetz, Laura G; Mamillapalli, Ramanaiah; Devlin, Maureen J; Robbins, Amy E; Majidi-Zolbin, Masoumeh; Taylor, Hugh S
2017-11-01
Cross-sex hormone therapy (XHT) is widely used by transgender people to alter secondary sex characteristics to match their desired gender presentation. Here, we investigate the long-term effects of XHT on bone health using a murine model. Female mice underwent ovariectomy at either 6 or 10 wk and began weekly testosterone or vehicle injections. Dual-energy X-ray absorptiometry (DXA) was performed (20 wk) to measure bone mineral density (BMD), and microcomputed tomography was performed to compare femoral cortical and trabecular bone architecture. The 6-wk testosterone group had comparable BMD with controls by DXA but reduced bone volume fraction, trabecular number, and cortical area fraction and increased trabecular separation by microcomputed tomography. Ten-week ovariectomy/XHT maintained microarchitecture, suggesting that estrogen is critical for bone acquisition during adolescence and that late, but not early, estrogen loss can be sufficiently replaced by testosterone alone. Given these findings, we then compared effects of testosterone with effects of weekly estrogen or combined testosterone/low-dose estrogen treatment after a 6-wk ovariectomy. Estrogen treatment increased spine BMD and microarchitecture, including bone volume fraction, trabecular number, trabecular thickness, and connectivity density, and decreased trabecular separation. Combined testosterone-estrogen therapy caused similar increases in femur and spine BMD and improved architecture (increased bone volume fraction, trabecular number, trabecular thickness, and connectivity density) to estrogen therapy and were superior compared with mice treated with testosterone only. These results demonstrate estradiol is critical for bone acquisition and suggest a new cross-sex hormone therapy adding estrogens to testosterone treatments with potential future clinical implications for treating transgender youth or men with estrogen deficiency. Copyright © 2017 the American Physiological Society.
Waspe, A C; Holdsworth, D W; Lacefield, J C; Fenster, A
2008-07-01
Preclinical research protocols often require the delivery of biological substances to specific targets in small animal disease models. To target biologically relevant locations in mice accurately, the needle positioning error needs to be < 200 μm. If targeting is inaccurate, experimental results can be inconclusive or misleading. We have developed a robotic manipulator that is capable of positioning a needle with a mean error < 100 μm. An apparatus and method were developed for integrating the needle-positioning robot with volumetric micro-computed tomography image guidance for interventions in small animals. Accurate image-to-robot registration is critical for integration as it enables targets identified in the image to be mapped to physical coordinates inside the animal. Registration is accomplished by injecting barium sulphate into needle tracks as the robot withdraws the needle from target points in a tissue-mimicking phantom. Registration accuracy is therefore affected by the positioning error of the robot and is assessed by measuring the point-to-line fiducial and target registration errors (FRE, TRE). Centroid points along cross-sectional slices of the track are determined using region growing segmentation followed by application of a center-of-mass algorithm. The centerline points are registered to needle trajectories in robot coordinates by applying an iterative closest point algorithm between points and lines. Implementing this procedure with four fiducial needle tracks produced a point-to-line FRE and TRE of 246 ± 58 μm and 194 ± 18 μm, respectively. The proposed registration technique produced a TRE < 200 μm, in the presence of robot positioning error, meeting design specification. © 2008 American Association of Physicists in Medicine.
Waspe, Adam C; McErlain, David D; Pitelka, Vasek; Holdsworth, David W; Lacefield, James C; Fenster, Aaron
2010-04-01
Preclinical research protocols often require insertion of needles to specific targets within small animal brains. To target biologically relevant locations in rodent brains more effectively, a robotic device has been developed that is capable of positioning a needle along oblique trajectories through a single burr hole in the skull under volumetric microcomputed tomography (micro-CT) guidance. An x-ray compatible stereotactic frame secures the head throughout the procedure using a bite bar, nose clamp, and ear bars. CT-to-robot registration enables structures identified in the image to be mapped to physical coordinates in the brain. Registration is accomplished by injecting a barium sulfate contrast agent as the robot withdraws the needle from predefined points in a phantom. Registration accuracy is affected by the robot-positioning error and is assessed by measuring the surface registration error for the fiducial and target needle tracks (FRE and TRE). This system was demonstrated in situ by injecting 200 microm tungsten beads into rat brains along oblique trajectories through a single burr hole on the top of the skull under micro-CT image guidance. Postintervention micro-CT images of each skull were registered with preintervention high-field magnetic resonance images of the brain to infer the anatomical locations of the beads. Registration using four fiducial needle tracks and one target track produced a FRE and a TRE of 96 and 210 microm, respectively. Evaluation with tissue-mimicking gelatin phantoms showed that locations could be targeted with a mean error of 154 +/- 113 microm. The integration of a robotic needle-positioning device with volumetric micro-CT image guidance should increase the accuracy and reduce the invasiveness of stereotactic needle interventions in small animals.
Sacco, Sandra M; Saint, Caitlin; Longo, Amanda B; Wakefield, Charles B; Salmon, Phil L; LeBlanc, Paul J; Ward, Wendy E
2017-01-01
Long-term effects of repeated i n vivo micro-computed tomography (μCT) scanning at key stages of growth and bone development (ages 2, 4 and 6 months) on trabecular and cortical bone structure, as well as developmental patterns, have not been studied. We determined the effect of repetitive μCT scanning at age 2, 4 and 6 months on tibia bone structure of male and female CD-1 mice and characterized developmental changes. At 2, 4 and 6 months of age, right tibias were scanned using in vivo μCT (Skyscan 1176) at one of three doses of radiation per scan: 222, 261 or 460 mGy. Left tibias of the same mice were scanned only at 6 months to serve as non-irradiated controls to determine whether recurrent radiation exposure alters trabecular and cortical bone structure at the proximal tibia. In males, eccentricity was lower ( P <0.05) in irradiated compared with non-irradiated tibias (222 mGy group). Within each sex, all other structural outcomes were similar between irradiated and non-irradiated tibias regardless of dose. Trabecular bone loss occurred in all mice due to age while cortical development continued to age 6 months. In conclusion, repetitive μCT scans at various radiation doses did not damage trabecular or cortical bone structure of proximal tibia in male and female CD-1 mice. Moreover, scanning at 2, 4 and 6 months of age highlight the different developmental time course between trabecular and cortical bone. These scanning protocols can be used to investigate longitudinal responses of bone structures to an intervention.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Voltolini, Marco; Kwon, Tae-Hyuk; Ajo-Franklin, Jonathan
Pore-scale distribution of supercritical CO 2 (scCO 2) exerts significant control on a variety of key hydrologic as well as geochemical processes, including residual trapping and dissolution. Despite such importance, only a small number of experiments have directly characterized the three-dimensional distribution of scCO 2 in geologic materials during the invasion (drainage) process. Here, we present a study which couples dynamic high-resolution synchrotron X-ray micro-computed tomography imaging of a scCO 2/brine system at in situ pressure/temperature conditions with quantitative pore-scale modeling to allow direct validation of a pore-scale description of scCO2 distribution. The experiment combines high-speed synchrotron radiography with tomographymore » to characterize the brine saturated sample, the scCO 2 breakthrough process, and the partially saturated state of a sandstone sample from the Domengine Formation, a regionally extensive unit within the Sacramento Basin (California, USA). The availability of a 3D dataset allowed us to examine correlations between grains and pores morphometric parameters and the actual distribution of scCO 2 in the sample, including the examination of the role of small-scale sedimentary structure on CO2 distribution. The segmented scCO 2/brine volume was also used to validate a simple computational model based on the local thickness concept, able to accurately simulate the distribution of scCO 2 after drainage. The same method was also used to simulate Hg capillary pressure curves with satisfactory results when compared to the measured ones. Finally, this predictive approach, requiring only a tomographic scan of the dry sample, proved to be an effective route for studying processes related to CO 2 invasion structure in geological samples at the pore scale.« less
Pai, Vinay M; Kozlowski, Megan; Donahue, Danielle; Miller, Elishiah; Xiao, Xianghui; Chen, Marcus Y; Yu, Zu-Xi; Connelly, Patricia; Jeffries, Kenneth; Wen, Han
2012-05-01
The high spatial resolution of micro-computed tomography (micro-CT) is ideal for 3D imaging of coronary arteries in intact mouse heart specimens. Previously, micro-CT of mouse heart specimens utilized intravascular contrast agents that hardened within the vessel lumen and allowed a vascular cast to be made. However, for mouse coronary artery disease models, it is highly desirable to image coronary artery walls and highlight plaques. For this purpose, we describe an ex vivo contrast-enhanced micro-CT imaging technique based on tissue staining with osmium tetroxide (OsO(4) ) solution. As a tissue-staining contrast agent, OsO(4) is retained in the vessel wall and surrounding tissue during the fixation process and cleared from the vessel lumens. Its high X-ray attenuation makes the artery wall visible in CT. Additionally, since OsO(4) preferentially binds to lipids, it highlights lipid deposition in the artery wall. We performed micro-CT of heart specimens of 5- to 25-week-old C57BL/6 wild-type mice and 5- to 13-week-old apolipoprotein E knockout (apoE(-/-) ) mice at 10 μm resolution. The results show that walls of coronary arteries as small as 45 μm in diameter are visible using a table-top micro-CT scanner. Similar image clarity was achieved with 1/2000th the scan time using a synchrotron CT scanner. In 13-week-old apoE mice, lipid-rich plaques are visible in the aorta. Our study shows that the combination of OsO(4) and micro-CT permits the visualization of the coronary artery wall in intact mouse hearts. Published 2012. This article is a US Government work and is in the public domain in the USA. Journal of Anatomy © 2012 Anatomical Society.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Moding, Everett J.; Clark, Darin P.; Qi, Yi
2013-04-01
Purpose: To evaluate the effects of radiation therapy on primary tumor vasculature using dual-energy (DE) micro-computed tomography (micro-CT). Methods and Materials: Primary sarcomas were generated with mutant Kras and p53. Unirradiated tumors were compared with tumors irradiated with 20 Gy. A liposomal-iodinated contrast agent was administered 1 day after treatment, and mice were imaged immediately after injection (day 1) and 3 days later (day 4) with DE micro-CT. CT-derived tumor sizes were used to assess tumor growth. After DE decomposition, iodine maps were used to assess tumor fractional blood volume (FBV) at day 1 and tumor vascular permeability at daymore » 4. For comparison, tumor vascularity and vascular permeability were also evaluated histologically by use of CD31 immunofluorescence and fluorescently-labeled dextrans. Results: Radiation treatment significantly decreased tumor growth from day 1 to day 4 (P<.05). There was a positive correlation between CT measurement of tumor FBV on day 1 and extravasated iodine on day 4 with microvascular density (MVD) on day 4 (R{sup 2}=0.53) and dextran accumulation (R{sup 2}=0.63) on day 4, respectively. Despite no change in MVD measured by histology, tumor FBV significantly increased after irradiation as measured by DE micro-CT (0.070 vs 0.091, P<.05). Both dextran and liposomal-iodine accumulation in tumors increased significantly after irradiation, with dextran fractional area increasing 5.2-fold and liposomal-iodine concentration increasing 4.0-fold. Conclusions: DE micro-CT is an effective tool for noninvasive assessment of vascular changes in primary tumors. Tumor blood volume and vascular permeability increased after a single therapeutic dose of radiation treatment.« less
Dursun, Ceyda Kanli; Dursun, Erhan; Eratalay, Kenan; Orhan, Kaan; Tatar, Ilkan; Baris, Emre; Tözüm, Tolga Fikret
2016-03-01
The aim of this randomized controlled study was to comparatively analyze the new bone (NB), residual bone, and graft-bone association in bone biopsies retrieved from augmented maxillary sinus sites by histomorphometry and microcomputed tomography (MicroCT) in a split-mouth model to test the efficacy of porous titanium granules (PTG) in maxillary sinus augmentation. Fifteen patients were included in the study and each patient was treated with bilateral sinus augmentation procedure using xenograft (equine origine, granule size 1000-2000 μm) and xenograft (1 g) + PTG (granule size 700-1000 μm, pore size >50 μm) (1 g), respectively. After a mean of 8.4 months, 30 bone biopsies were retrieved from the implant sites for three-dimensional MicroCT and two-dimensional histomorphometric analyses. Bone volume and vital NB percentages were calculated. Immediate after core biopsy, implants having standard dimensions were placed and implant stability quotient values were recorded at baseline and 3 months follow-up. There were no significant differences between groups according to residual bone height, residual bone width, implant dimensions, and implant stability quotient values (baseline and 3 months). According to MicroCT and two-dimensional histomorphometric analyses, the volume of newly formed bone was 57.05% and 52.67%, and 56.5% and 55.08% for xenograft + PTG and xenograft groups, respectively. No statistically significant differences found between groups according to NB percentages and higher Hounsfield unit values were found for xenograft + PTG group. The findings of the current study supports that PTG, which is a porous, permanent nonresorbable bone substitute, may have a beneficial osteoconductive effect on mechanical strength of NB in augmented maxillary sinus.
Lee, Jung Min; Kim, Ji Heui; Lee, Ok Joo; Park, Chan Hum
2013-06-01
Bioresorbable fixation systems have been popular for the treatment of facial fractures. However, their mechanical properties are uncertain and complications have been reported. To overcome these problems, we developed a bioresorbable fixation plate using a composite of silk fibroin and bacterial cellulose (SF-BC) with biodegradability and increased biocompatibility. To investigate the regenerative effect of the bioresorbable SF-BC fixation plate on zygomatic arch defects in rats. In vivo animal study. The SF-BC composite plate had a tensile strength similar to that of a polylactic acid plate and a tight, pore-free microstructure. Bilateral segmental bone defects (2 mm in length) were created in the zygomatic arches of adult rats. One side was fixed with the SF-BC composite plate, and the other side was left without fixation. Academic research laboratory. Fifteen adult Sprague-Dawley rats. Fixation of the zygomatic arch defect with the SF-BC composite plate. Micro-computed tomography and histological evaluation of bone samples. Gross inspection revealed no specific complication. At 1, 2, 4, and 8 postoperative weeks, the zygomatic arches were explored by micro-computed tomography and histological examination. Control sides did not heal completely and showed bony degeneration and necrosis during the 8-week follow-up. However, we observed new bone formation in sides treated with the SF-BC composite plate, and bony defects were completely healed within 8 weeks. The SF-BC composite plate is a potential candidate for a new bioresorbable fixation system. Our composite material could considerably shorten bone regeneration time. Additional study of the control of biodegradability and mechanical properties of SF-BC composite plates and a comparative study with the resorbable plates currently in use should be undertaken.
Govindarajan, Parameswari; Böcker, Wolfgang; El Khassawna, Thaqif; Kampschulte, Marian; Schlewitz, Gudrun; Huerter, Britta; Sommer, Ursula; Dürselen, Lutz; Ignatius, Anita; Bauer, Natali; Szalay, Gabor; Wenisch, Sabine; Lips, Katrin S; Schnettler, Reinhard; Langheinrich, Alexander; Heiss, Christian
2014-03-01
In estrogen-deficient, postmenopausal women, vitamin D and calcium deficiency increase osteoporotic fracture risk. Therefore, a new rat model of combined ovariectomy and multiple-deficient diet was established to mimic human postmenopausal osteoporotic conditions under nutrient deficiency. Sprague-Dawley rats were untreated (control), laparatomized (sham), or ovariectomized and received a deficient diet (OVX-Diet). Multiple analyses involving structure (micro-computed tomography and biomechanics), cellularity (osteoblasts and osteoclasts), bone matrix (mRNA expression and IHC), and mineralization were investigated for a detailed characterization of osteoporosis. The study involved long-term observation up to 14 months (M14) after laparotomy or after OVX-Diet, with intermediate time points at M3 and M12. OVX-Diet rats showed enhanced osteoblastogenesis and osteoclastogenesis. Bone matrix markers (biglycan, COL1A1, tenascin C, and fibronectin) and low-density lipoprotein-5 (bone mass marker) were down-regulated at M12 in OVX-Diet rats. However, up-regulation of matrix markers and existence of unmineralized osteoid were seen at M3 and M14. Osteoclast markers (matrix metallopeptidase 9 and cathepsin K) were up-regulated at M14. Micro-computed tomography and biomechanics confirmed bone fragility of OVX-Diet rats, and quantitative RT-PCR revealed a higher turnover rate in the humerus than in lumbar vertebrae, suggesting enhanced bone formation and resorption in OVX-Diet rats. Such bone remodeling caused disturbed bone mineralization and severe bone loss, as reported in patients with high-turnover, postmenopausal osteoporosis. Therefore, this rat model may serve as a suitable tool to evaluate osteoporotic drugs and new biomaterials or fracture implants. Copyright © 2014 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.
Evaluation of Titanium-Coated Pedicle Screws: In Vivo Porcine Lumbar Spine Model.
Kim, Do-Yeon; Kim, Jung-Ryul; Jang, Kyu Yun; Kim, Min Gu; Lee, Kwang-Bok
2016-07-01
Many studies have addressed the problem of loosening pedicle screws in spinal surgery, which is a serious concern. Titanium coating of medical implants (arthroplasty) is common, but few studies involving in vivo spine models have been reported. We evaluated the radiological, mechanical, and histological characteristics of titanium-coated pedicle screws compared with uncoated or hydroxyapatite-coated pedicle screws. Three different types of pedicle screws, i.e., uncoated, hydroxyapatite-coated, and titanium-coated, were implanted into the lumbar 3-4-5 levels of 9 mature miniature pigs. Radiological evaluation of loosening of pedicle screws was performed. Peak torsional extraction torque was tested in the 42 screws from 7 miniature pigs at 12 weeks postoperatively. The implant-bone interface of the remaining 12 pedicle screws from 2 miniature pigs in each group was assessed by micro-computed tomography and histologic studies. The incidence of loosening at 12 weeks postoperatively was not significantly different between the titanium-coated pedicle screw group and the other groups. The titanium-coated pedicle screw group exhibited the greatest mean extraction torsional peak torque at 12 weeks postoperatively (P < 0.05). Quantitative micro-computed tomography data were greatest in the titanium-coated pedicle screw group (P < 0.05). Histologic findings showed osteointegration with densely packed new bone formation at the screw coating-bone interface in the titanium-coated pedicle screw group. Fixation strength was greatest in the titanium-coated pedicle screw group. Osteointegration at the interface between the titanium-coated implant and bone produced prominent and firm bonding. The titanium-coated pedicle screw is a promising device for application in spinal surgery. Copyright © 2016 Elsevier Inc. All rights reserved.
Coronary artery wall imaging in mice using osmium tetroxide and micro-computed tomography (micro-CT)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pai, Vinay M.; Kozlowski, Megan; Donahue, Danielle
2012-05-10
The high spatial resolution of micro-computed tomography (micro-CT) is ideal for 3D imaging of coronary arteries in intact mouse heart specimens. Previously, micro-CT of mouse heart specimens utilized intravascular contrast agents that hardened within the vessel lumen and allowed a vascular cast to be made. However, for mouse coronary artery disease models, it is highly desirable to image coronary artery walls and highlight plaques. For this purpose, we describe an ex vivo contrast-enhanced micro-CT imaging technique based on tissue staining with osmium tetroxide (OsO{sub 4}) solution. As a tissue-staining contrast agent, OsO{sub 4} is retained in the vessel wall andmore » surrounding tissue during the fixation process and cleared from the vessel lumens. Its high X-ray attenuation makes the artery wall visible in CT. Additionally, since OsO{sub 4} preferentially binds to lipids, it highlights lipid deposition in the artery wall. We performed micro-CT of heart specimens of 5- to 25-week-old C57BL/6 wild-type mice and 5- to 13-week-old apolipoprotein E knockout (apoE{sup -/-}) mice at 10 {mu}m resolution. The results show that walls of coronary arteries as small as 45 {mu}m in diameter are visible using a table-top micro-CT scanner. Similar image clarity was achieved with 1/2000th the scan time using a synchrotron CT scanner. In 13-week-old apoE mice, lipid-rich plaques are visible in the aorta. Our study shows that the combination of OsO{sub 4} and micro-CT permits the visualization of the coronary artery wall in intact mouse hearts.« less
Compression and flexural strength of bone cement mixed with blood.
Tan, J H; Koh, B Th; Ramruttun, A K; Wang, W
2016-08-01
To assess the compression and flexural strength of bone cement mixed with 0 ml, 1 ml, or 2 ml of blood. High viscosity polymethyl methacrylate (PMMA) loaded with or without gentamicin was used. Blood was collected from total knee arthroplasty patients. In the same operating room, one pack of cement each was mixed with 0 ml (control), 1 ml, or 2 ml of blood for 1 minute during the dough phase. The dough was extruded into cylindrical and rectangular moulds for 20 minutes of setting, and then cured in phosphate buffered saline at 37±1ºC for 7 days. The samples were visually inspected for fractures and areas of weakness, and then scanned using microcomputed tomography. 48 gentamicin-loaded and 59 non-gentamicin-loaded samples mixed with 0 ml (control), 1 ml, or 2 ml of blood were randomised for flexural and compression strength testing; each group had at least 6 samples. In samples loaded with or without gentamicin, the flexural and compressive strength was highest in controls, followed by samples mixed with 1 ml or 2 ml of blood. In samples mixed with 2 ml of blood, the flexural strength fell below the standard of 50 MPa. In samples mixed with 2 ml of blood and all gentamicin-loaded samples, the compressive strength fell below the standard of 70 MPa. Microcomputed tomography revealed areas of voids and pores indicating the presence of laminations and partitions within. The biomechanical strength of PMMA contaminated with blood may decrease. Precautions such as saline lavage, pack drying the bone, change of gloves, and prompt insertion of the implant should be taken to prevent blood from contaminating bone cement.
Pasqualini, Damiano; Alovisi, Mario; Cemenasco, Andrea; Mancini, Lucia; Paolino, Davide Salvatore; Bianchi, Caterina Chiara; Roggia, Andrea; Scotti, Nicola; Berutti, Elio
2015-10-01
The aim of this micro-computed tomography study was to describe the shaping properties of ProGlider/ProTaper Next (PG/PTN) and ScoutRace/BioRace (SR/BR) nickel-titanium rotary systems. Thirty maxillary first permanent molars were selected. Mesiobuccal canals were randomly assigned (n = 15) to PG/PTN or SR/BR groups. Irrigation was performed with 5% NaOCl and 10% EDTA. Specimens were scanned (voxel size, 9.1 μm) for matching volumes and surface areas and post-treatment analyses. Root canal centering ability, canal geometry enlargement, and thickness of dentinal wall at inner curvature were assessed at apical level and point of maximum curvature. Results were analyzed with 4 one-way analyses of variance. Canal centering ability was superior in PG/PTN (P = .006 at apical level, P = .025 at point of maximum curvature). PG/PTN demonstrated a more conservative increase of canal areas (P = .027 at apical level, P = .038 at point of maximum curvature). Centrifugal increase in canal diameters did not significantly differ between groups (P = .65 at apical level, P = .61 at point of maximum curvature). Inner dentinal wall thickness was less reduced with PG/PTN compared with SR/BR, with no statistical differences (P = .23 at point of maximum curvature, P = .89 at apical level). PG/PTN shaping taper ranged between 6% and 7%. Neither system produced significant shaping errors in curved canals. PG/PTN system showed better preservation of canal anatomy. PTN offset section did not influence final preparation taper. Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Uzgur, Recep; Ercan, Ertuğrul; Uzgur, Zeynep; Çolak, Hakan; Yalçın, Muhammet; Özcan, Mutlu
2016-08-12
To evaluate the marginal and internal cement thicknesses of inlay restorations made of various CAD/CAM materials using 3D X-ray micro-computed tomography (micro-CT) technique. Caries-free extracted mandibular molars (N = 30) with similar size were randomly assigned to three groups (N = 10 per group). Mesio-occlusal-distal (MOD) cavities were prepared, and inlay restorations were obtained by milling out CAD/CAM materials namely, (a) IPS: monolithic lithium disilicate (control), (b) VE: polymer-infiltrated ceramic, and (c) CS: nano-ceramic using a CAM unit. Marginal and internal cement thicknesses were measured using 3D micro-CT. Data were analyzed using 1-way ANOVA and Tukey's tests (alpha = 0.05). The mean marginal and internal cement thickness were not significant in all inlay materials (p > 0.05). Mean marginal cement thickness (μm) was the lowest for the IPS group (67.54 ± 10.16) followed by VE (84.09 ± 3.94) and CS (95.18 ± 10.58) (p > 0.05). The internal cement thickness (μm) was the lowest in the CS group (54.85 ± 6.94) followed by IPS (60.58 ± 9.22) and VE (77.53 ± 12.13) (p > 0.05). Marginal and internal cement thicknesses of MOD inlays made of monolithic lithium disilicate, polymer-infiltrated ceramic, and nano-ceramic CAD/CAM materials were similar and all less than 100 μm, which could be considered clinically acceptable. MOD inlays made of different CAD/CAM materials presented similar cement thickness, less than 100 μm. © 2016 by the American College of Prosthodontists.
Longitudinal in vivo microcomputed tomography of mouse lungs: No evidence for radiotoxicity
Vande Velde, Greetje; De Langhe, Ellen; Poelmans, Jennifer; Bruyndonckx, Peter; d'Agostino, Emiliano; Verbeken, Erik; Bogaerts, Ria; Himmelreich, Uwe
2015-01-01
Before microcomputed tomography (micro-CT) can be exploited to its full potential for longitudinal monitoring of transgenic and experimental mouse models of lung diseases, radiotoxic side effects such as inflammation or fibrosis must be considered. We evaluated dose and potential radiotoxicity to the lungs for long-term respiratory-gated high-resolution micro-CT protocols. Free-breathing C57Bl/6 mice underwent four different retrospectively respiratory gated micro-CT imaging schedules of repeated scans during 5 or 12 wk, followed by ex vivo micro-CT and detailed histological and biochemical assessment of lung damage. Radiation exposure, dose, and absorbed dose were determined by ionization chamber, thermoluminescent dosimeter measurements and Monte Carlo calculations. Despite the relatively large radiation dose delivered per micro-CT acquisition, mice did not show any signs of radiation-induced lung damage or fibrosis when scanned weekly during 5 and up to 12 wk. Doubling the scanning frequency and once tripling the radiation dose as to mimic the instant repetition of a failed scan also stayed without detectable toxicity after 5 wk of scanning. Histological analyses confirmed the absence of radiotoxic damage to the lungs, thereby demonstrating that long-term monitoring of mouse lungs using high-resolution micro-CT is safe. This opens perspectives for longitudinal monitoring of (transgenic) mouse models of lung diseases and therapeutic response on an individual basis with high spatial and temporal resolution, without concerns for radiation toxicity that could potentially influence the readout of micro-CT-derived lung biomarkers. This work further supports the introduction of micro-CT for routine use in the preclinical pulmonary research field where postmortem histological approaches are still the gold standard. PMID:26024893
Kim, Andrew J.; Francis, Richard; Liu, Xiaoqin; Devine, William A.; Ramirez, Ricardo; Anderton, Shane J.; Wong, Li Yin; Faruque, Fahim; Gabriel, George C.; Leatherbury, Linda; Tobita, Kimimasa; Lo, Cecilia W.
2013-01-01
Background Mice are well suited for modeling human congenital heart defects (CHD), given their four-chamber cardiac anatomy. However, mice with CHD invariably die prenatally/neonatally, causing CHD phenotypes to be missed. Therefore, we investigated the efficacy of noninvasive micro-computed tomography (micro-CT) to screen for CHD in stillborn/fetal mice. These studies were carried out using chemically mutagenized mice expected to be enriched for birth defects including CHD. Methods and Results Stillborn/fetal mice obtained from the breeding of N-ethyl-N-nitrosourea (ENU) mutagenized mice were formalin-fixed and stained with iodine, then micro-CT scanned. Those diagnosed with CHD and some CHD-negative pups were necropsied. A subset of these were further analyzed by histopathology to confirm the CHD/no-CHD diagnosis. Micro-CT scanning of 2105 fetal/newborn mice revealed an abundance of ventricular septal defects (VSD) (n=307). Overall, we observed an accuracy of 89.8% for VSD diagnosis. Outflow tract anomalies identified by micro-CT included double outlet right ventricle (n=36), transposition of the great arteries (n=14), and persistent truncus arteriosus (n=3). These were diagnosed with a 97.4% accuracy. Aortic arch anomalies also were readily detected with an overall 99.6% accuracy. This included right aortic arch (n=28) and coarctation/interrupted aortic arch (n=12). Also detected by micro-CT were atrioventricular septal defects (n=22), tricuspid hypoplasia/atresia (n=13), and coronary artery fistulas (n=16). They yielded accuracies of 98.9%, 100%, and 97.8% respectively. Conclusions Contrast enhanced micro-CT imaging in neonatal/fetal mice can reliably detect a wide spectrum of CHD. We conclude micro-CT imaging can be used for routine rapid assessments of structural heart defects in fetal/newborn mice. PMID:23759365
Tokunaga, Takuya; Karasugi, Tatsuki; Arimura, Hitoshi; Yonemitsu, Ryuji; Sakamoto, Hidetoshi; Ide, Junji; Mizuta, Hiroshi
2017-10-01
Application of fibroblast growth factor 2 (FGF-2) may improve the healing response after rotator cuff (RC) surgical repair. This study aimed to determine whether FGF-2-impregnated gelatin hydrogel sheet (GHS) incorporation into the bony trough on the greater tuberosity facilitates healing after RC surgical repair in rabbits. We assigned 120 adult male Japanese white rabbits treated with unilateral surgery for supraspinatus tendon repair into the following groups: suture-only group (suture); suture and GHS with phosphate-buffered saline (carrier); suture and GHS with 3 µg of FGF-2 (F3); and suture and GHS with 30 µg of FGF-2 (F30). The effect of FGF-2 was assessed using histologic, biomechanical, and microcomputed tomography evaluations at 2, 6, and 12 weeks. At 12 weeks, loose fibrovascular tissues emerged at the repair site in the suture and carrier groups and dense tendon-like tissues in the F3 and F30 groups, which demonstrated significantly higher ultimate load-to-failure and stress-to-failure at 12 weeks than that in the suture and carrier groups. Microcomputed tomography imaging showed ectopic calcification formation in some specimens from each group. Appearances or frequencies were similar among groups. The histologic and biomechanical effects of FGF-2 on RC healing were obvious at ≥6 weeks postoperatively. FGF-2-impregnated GHS incorporation into the bony trough on the greater tuberosity before RC surgical repair is feasible and results in histologic and biomechanical improvements during RC healing in rabbits. No detrimental effect on ectopic calcification was observed. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
Chen, Xiao-bo; Chen, Chen; Liang, Yu-hong
2016-02-18
To evaluate the efficacy and security of two type of rotary nickel titanium system (Twisted File and ProTaper Universal) for root canal preparation based on micro-computed tomography(micro-CT). Twenty extracted molars (including 62 canals) were divided into two experimental groups and were respectively instrumented using Twisted File rotary nickel titanium system (TF) and ProTaper Universal rotary nickel titanium system (PU) to #25/0.08 following recommended protocol. Time for root canal instrumentation (accumulation of time for every single file) was recorded. The 0-3 mm root surface from apex was observed under an optical stereomicroscope at 25 × magnification. The presence of crack line was noted. The root canals were scanned with micro-CT before and after root canal preparation. Three-dimensional shape images of canals were reconstructed, calculated and evaluated. The amount of canal central transportation of the two groups was calculated and compared. The shorter preparation time [(0.53 ± 0.14) min] was observed in TF group, while the preparation time of PU group was (2.06 ± 0.39) min (P<0.05). In mid-root level, TF group shaping resulted in less canal center transportation than PU group [(0.070 ± 0.056) mm vs. (0.097 ± 0.084) mm, P<0.05]. No instrument separation was observed in both the groups. Cracks were not found in both the groups either based in micro-CT images or observation under an optical stereomicroscope at 25 × magnification. Compared with ProTaper Universal, Twisted File took less time in root canal preparation and exhibited better shaping ability, and less canal transportation.
Voltolini, Marco; Kwon, Tae-Hyuk; Ajo-Franklin, Jonathan
2017-10-21
Pore-scale distribution of supercritical CO 2 (scCO 2) exerts significant control on a variety of key hydrologic as well as geochemical processes, including residual trapping and dissolution. Despite such importance, only a small number of experiments have directly characterized the three-dimensional distribution of scCO 2 in geologic materials during the invasion (drainage) process. Here, we present a study which couples dynamic high-resolution synchrotron X-ray micro-computed tomography imaging of a scCO 2/brine system at in situ pressure/temperature conditions with quantitative pore-scale modeling to allow direct validation of a pore-scale description of scCO2 distribution. The experiment combines high-speed synchrotron radiography with tomographymore » to characterize the brine saturated sample, the scCO 2 breakthrough process, and the partially saturated state of a sandstone sample from the Domengine Formation, a regionally extensive unit within the Sacramento Basin (California, USA). The availability of a 3D dataset allowed us to examine correlations between grains and pores morphometric parameters and the actual distribution of scCO 2 in the sample, including the examination of the role of small-scale sedimentary structure on CO2 distribution. The segmented scCO 2/brine volume was also used to validate a simple computational model based on the local thickness concept, able to accurately simulate the distribution of scCO 2 after drainage. The same method was also used to simulate Hg capillary pressure curves with satisfactory results when compared to the measured ones. Finally, this predictive approach, requiring only a tomographic scan of the dry sample, proved to be an effective route for studying processes related to CO 2 invasion structure in geological samples at the pore scale.« less
Lee, Ki-Wook; Kim, Yeun; Perinpanayagam, Hiran; Lee, Jong-Ki; Yoo, Yeon-Jee; Lim, Sang-Min; Chang, Seok Woo; Ha, Byung-Hyun; Zhu, Qiang; Kum, Kee-Yeon
2014-03-01
Micro-computed tomography (MCT) shows detailed root canal morphology that is not seen with traditional tooth clearing. However, alternative image reformatting techniques in MCT involving 2-dimensional (2D) minimum intensity projection (MinIP) and 3-dimensional (3D) volume-rendering reconstruction have not been directly compared with clearing. The aim was to compare alternative image reformatting techniques in MCT with tooth clearing on the mesiobuccal (MB) root of maxillary first molars. Eighteen maxillary first molar MB roots were scanned, and 2D MinIP and 3D volume-rendered images were reconstructed. Subsequently, the same MB roots were processed by traditional tooth clearing. Images from 2D, 3D, 2D + 3D, and clearing techniques were assessed by 4 endodontists to classify canal configuration and to identify fine anatomic structures such as accessory canals, intercanal communications, and loops. All image reformatting techniques in MCT showed detailed configurations and numerous fine structures, such that none were classified as simple type I or II canals; several were classified as types III and IV according to Weine classification or types IV, V, and VI according to Vertucci; and most were nonclassifiable because of their complexity. The clearing images showed less detail, few fine structures, and numerous type I canals. Classification of canal configuration was in 100% intraobserver agreement for all 18 roots visualized by any of the image reformatting techniques in MCT but for only 4 roots (22.2%) classified according to Weine and 6 (33.3%) classified according to Vertucci, when using the clearing technique. The combination of 2D MinIP and 3D volume-rendered images showed the most detailed canal morphology and fine anatomic structures. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Yang, Chongshi; Zhang, Yuanyuan; Zhang, Yan; Fan, Yubo; Deng, Feng
2015-01-01
Despite various X-ray approaches have been widely used to monitor root resorption after orthodontic treatment, a non-invasive and accurate method is highly desirable for long-term follow up. The aim of this study was to build a non-invasive method to quantify longitudinal orthodontic root resorption with time-lapsed images of micro-computed tomography (micro-CT) in a rodent model. Twenty male Sprague Dawley (SD) rats (aged 6-8 weeks, weighing 180-220 g) were used in this study. A 25 g orthodontic force generated by nickel-titanium coil spring was applied to the right maxillary first molar for each rat, while contralateral first molar was severed as a control. Micro-CT scan was performed at day 0 (before orthodontic load) and days 3, 7, 14, and 28 after orthodontic load. Resorption of mesial root of maxillary first molars at bilateral sides was calculated from micro-CT images with registration algorithm via reconstruction, superimposition and partition operations. Obvious resorption of mesial root of maxillary first molar can be detected at day 14 and day 28 at orthodontic side. Most of the resorption occurred in the apical region at distal side and cervical region at mesiolingual side. Desirable development of molar root of rats was identified from day 0 to day 28 at control side. The development of root concentrated on apical region. This non-invasive 3D quantification method with registration algorithm can be used in longitudinal study of root resorption. Obvious root resorption in rat molar can be observed three-dimensionally at day 14 and day 28 after orthodontic load. This indicates that registration algorithm combined with time-lapsed images provides clinic potential application in detection and quantification of root contour.
Fischenich, Kristine M.; Pauly, Hannah M.; Button, Keith D.; Fajardo, Ryan S.; DeCamp, Charles E.; Haut, Roger C.; Haut Donahue, Tammy L.
2016-01-01
Objective The objective of this study was to monitor the progression of joint damage in two animal models of knee joint trauma using two non-invasive, clinically available imaging modalities. Methods A 3-T clinical magnet and micro-computed tomography (mCT) was used to document changes immediately following injury (acute) and post-injury (chronic) at time points of 4, 8, or 12 weeks. Joint damage was recorded at dissection and compared to the chronic magnetic resonance imaging (MRI) record. Fifteen Flemish Giant rabbits were subjected to a single tibiofemoral compressive impact (ACLF), and 18 underwent a combination of anterior cruciate ligament (ACL) and meniscal transection (mACLT). Results All ACLF animals experienced ACL rupture, and 13 also experienced acute meniscal damage. All ACLF and mACLT animals showed meniscal and articular cartilage damages at dissection. Meniscal damage was documented as early as 4 weeks and worsened in 87% of the ACLF animals and 71% of the mACLT animals. Acute cartilage damage also developed further and increased in occurrence with time in both models. A progressive decrease in bone quantity and quality was documented in both models. The MRI data closely aligned with dissection notes suggesting this clinical tool may be a non-invasive method for documenting joint damage in lapine models of knee joint trauma. Conclusions The study investigates the acute to chronic progression of meniscal and cartilage damage at various time points, and chronic changes to the underlying bone in two models of posttraumatic osteoarthritis (PTOA), and highlights the dependency of the model on the location, type, and progression of damage over time. PMID:27756698
DOE Office of Scientific and Technical Information (OSTI.GOV)
Waspe, Adam C.; McErlain, David D.; Pitelka, Vasek
Purpose: Preclinical research protocols often require insertion of needles to specific targets within small animal brains. To target biologically relevant locations in rodent brains more effectively, a robotic device has been developed that is capable of positioning a needle along oblique trajectories through a single burr hole in the skull under volumetric microcomputed tomography (micro-CT) guidance. Methods: An x-ray compatible stereotactic frame secures the head throughout the procedure using a bite bar, nose clamp, and ear bars. CT-to-robot registration enables structures identified in the image to be mapped to physical coordinates in the brain. Registration is accomplished by injecting amore » barium sulfate contrast agent as the robot withdraws the needle from predefined points in a phantom. Registration accuracy is affected by the robot-positioning error and is assessed by measuring the surface registration error for the fiducial and target needle tracks (FRE and TRE). This system was demonstrated in situ by injecting 200 {mu}m tungsten beads into rat brains along oblique trajectories through a single burr hole on the top of the skull under micro-CT image guidance. Postintervention micro-CT images of each skull were registered with preintervention high-field magnetic resonance images of the brain to infer the anatomical locations of the beads. Results: Registration using four fiducial needle tracks and one target track produced a FRE and a TRE of 96 and 210 {mu}m, respectively. Evaluation with tissue-mimicking gelatin phantoms showed that locations could be targeted with a mean error of 154{+-}113 {mu}m. Conclusions: The integration of a robotic needle-positioning device with volumetric micro-CT image guidance should increase the accuracy and reduce the invasiveness of stereotactic needle interventions in small animals.« less
NASA Astrophysics Data System (ADS)
Alvarenga de Moura Meneses, Anderson; Giusti, Alessandro; de Almeida, André Pereira; Parreira Nogueira, Liebert; Braz, Delson; Cely Barroso, Regina; deAlmeida, Carlos Eduardo
2011-12-01
Synchrotron Radiation (SR) X-ray micro-Computed Tomography (μCT) enables magnified images to be used as a non-invasive and non-destructive technique with a high space resolution for the qualitative and quantitative analyses of biomedical samples. The research on applications of segmentation algorithms to SR-μCT is an open problem, due to the interesting and well-known characteristics of SR images for visualization, such as the high resolution and the phase contrast effect. In this article, we describe and assess the application of the Energy Minimization via Graph Cuts (EMvGC) algorithm for the segmentation of SR-μCT biomedical images acquired at the Synchrotron Radiation for MEdical Physics (SYRMEP) beam line at the Elettra Laboratory (Trieste, Italy). We also propose a method using EMvGC with Artificial Neural Networks (EMANNs) for correcting misclassifications due to intensity variation of phase contrast, which are important effects and sometimes indispensable in certain biomedical applications, although they impair the segmentation provided by conventional techniques. Results demonstrate considerable success in the segmentation of SR-μCT biomedical images, with average Dice Similarity Coefficient 99.88% for bony tissue in Wistar Rats rib samples (EMvGC), as well as 98.95% and 98.02% for scans of Rhodnius prolixus insect samples (Chagas's disease vector) with EMANNs, in relation to manual segmentation. The techniques EMvGC and EMANNs cope with the task of performing segmentation in images with the intensity variation due to phase contrast effects, presenting a superior performance in comparison to conventional segmentation techniques based on thresholding and linear/nonlinear image filtering, which is also discussed in the present article.
Kim, Yoon Jeong; Henkin, Jeffrey
2015-04-01
Micro-computed tomography (micro-CT) is a valuable means to evaluate and secure information related to bone density and quality in human necropsy samples and small live animals. The aim of this study was to assess the bone density of the alveolar jaw bones in human cadaver, using micro-CT. The correlation between bone density and three-dimensional micro architecture of trabecular bone was evaluated. Thirty-four human cadaver jaw bone specimens were harvested. Each specimen was scanned with micro-CT at resolution of 10.5 μm. The bone volume fraction (BV/TV) and the bone mineral density (BMD) value within a volume of interest were measured. The three-dimensional micro architecture of trabecular bone was assessed. All the parameters in the maxilla and the mandible were subject to comparison. The variables for the bone density and the three-dimensional micro architecture were analyzed for nonparametric correlation using Spearman's rho at the significance level of p < .05. A wide range of bone density was observed. There was a significant difference between the maxilla and mandible. All micro architecture parameters were consistently higher in the mandible, up to 3.3 times greater than those in the maxilla. The most linear correlation was observed between BV/TV and BMD, with Spearman's rho = 0.99 (p = .01). Both BV/TV and BMD were highly correlated with all micro architecture parameters with Spearman's rho above 0.74 (p = .01). Two aspects of bone density using micro-CT, the BV/TV and BMD, are highly correlated with three-dimensional micro architecture parameters, which represent the quality of trabecular bone. This noninvasive method may adequately enhance evaluation of the alveolar bone. © 2013 Wiley Periodicals, Inc.
The microcomputer in cell and neurobiology research
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mize, R.R.
1985-01-01
This book contains 21 chapters. They are divided into the following sections: The Microcomputer as a Research Tool, Microcomputer Uses in Light and Electron Microscopy, Microcomputer Uses in Morphometry, Serial Section Reconstruction, Microcomputer Uses in Imaging and Densitometry, and Microcomputer Uses in Electrophysiology.
Xie, Tianwu; Zaidi, Habib
2016-01-01
The development of multimodality preclinical imaging techniques and the rapid growth of realistic computer simulation tools have promoted the construction and application of computational laboratory animal models in preclinical research. Since the early 1990s, over 120 realistic computational animal models have been reported in the literature and used as surrogates to characterize the anatomy of actual animals for the simulation of preclinical studies involving the use of bioluminescence tomography, fluorescence molecular tomography, positron emission tomography, single-photon emission computed tomography, microcomputed tomography, magnetic resonance imaging, and optical imaging. Other applications include electromagnetic field simulation, ionizing and nonionizing radiation dosimetry, and the development and evaluation of new methodologies for multimodality image coregistration, segmentation, and reconstruction of small animal images. This paper provides a comprehensive review of the history and fundamental technologies used for the development of computational small animal models with a particular focus on their application in preclinical imaging as well as nonionizing and ionizing radiation dosimetry calculations. An overview of the overall process involved in the design of these models, including the fundamental elements used for the construction of different types of computational models, the identification of original anatomical data, the simulation tools used for solving various computational problems, and the applications of computational animal models in preclinical research. The authors also analyze the characteristics of categories of computational models (stylized, voxel-based, and boundary representation) and discuss the technical challenges faced at the present time as well as research needs in the future.
A comparison of classical histology to anatomy revealed by hard x-rays
NASA Astrophysics Data System (ADS)
Richter, Claus-Peter; Tan, Xiaodong; Young, Hunter; Stock, Stuart; Robinson, Alan; Byskosh, Orest; Zheng, Jing; Soriano, Carmen; Xiao, Xianghui; Whitlon, Donna
2016-10-01
Many diseases trigger morphological changes in affected tissue. Today, classical histology is still the "gold standard" used to study and describe those changes. Classical histology, however, is time consuming and requires chemical tissue manipulations that can result in significant tissue distortions. It is sometimes difficult to separate tissue-processing artifacts from changes caused by the disease process. We show that synchrotron X-ray phase-contrast micro-computed tomography (micro-CT) can be used to examine non-embedded, hydrated tissue at a resolution comparable to that obtained with classical histology. The data analysis from stacks of reconstructed micro-CT images is more flexible and faster than when using the classical, physically embedded sections that are by necessity fixed in a particular orientation. We show that in a three-dimensional (3D) structure with meticulous structural details such as the cochlea and the kidney, micro-CT is more flexible, faster and more convenient for morphological studies and disease diagnoses.
Amber fossils demonstrate deep-time stability of Caribbean lizard communities.
Sherratt, Emma; del Rosario Castañeda, María; Garwood, Russell J; Mahler, D Luke; Sanger, Thomas J; Herrel, Anthony; de Queiroz, Kevin; Losos, Jonathan B
2015-08-11
Whether the structure of ecological communities can exhibit stability over macroevolutionary timescales has long been debated. The similarity of independently evolved Anolis lizard communities on environmentally similar Greater Antillean islands supports the notion that community evolution is deterministic. However, a dearth of Caribbean Anolis fossils--only three have been described to date--has precluded direct investigation of the stability of anole communities through time. Here we report on an additional 17 fossil anoles in Dominican amber dating to 15-20 My before the present. Using data collected primarily by X-ray microcomputed tomography (X-ray micro-CT), we demonstrate that the main elements of Hispaniolan anole ecomorphological diversity were in place in the Miocene. Phylogenetic analysis yields results consistent with the hypothesis that the ecomorphs that evolved in the Miocene are members of the same ecomorph clades extant today. The primary axes of ecomorphological diversity in the Hispaniolan anole fauna appear to have changed little between the Miocene and the present, providing evidence for the stability of ecological communities over macroevolutionary timescales.
Onset of molar incisor hypomineralization (MIH).
Fagrell, Tobias G; Salmon, Phil; Melin, Lisa; Norén, Jörgen G
2013-01-01
The etiological factors and timing of the onset of molar incisor hypomineralization (MIH) are still not clear. The aim of this study was to examine ground radial and sagittal sections from teeth diagnosed with MIH using light microscopy, polarized light microscopy and X-ray micro-computed tomography (XMCT) and to estimate the onset and timing of the MIH and to relate the hypomineralized enamel to the incremental lines. Thirteen extracted permanent first molars diagnosed MIH, were analyzed with light microscopy and XMCT. The hypomineralized areas were mainly located in the mesio-buccal cusps, starting at the enamel-dentin-junction and continuing towards the enamel surface. In a relative gray scale analysis the values decreased from the EDJ towards the enamel surface. The findings indicate that the ameloblasts in the hypomineralized enamel are capable of forming an enamel of normal thickness, but with a substantial reduction of their capacity for maturation of enamel. Chronologically, it is estimated that the timing of the disturbance is at a period during the first 6-7 months of age.
In vivo longitudinal micro-CT study of bent long limb bones in rat offspring.
De Schaepdrijver, Luc; Delille, Peter; Geys, Helena; Boehringer-Shahidi, Christian; Vanhove, Christian
2014-07-01
Micro-computed X-ray tomography (micro-CT) has been reported as a reliable method to assess ex vivo rat and rabbit fetal skeletons in embryo-fetal developmental toxicity studies. Since micro-CT is a non-invasive imaging modality it has the potential for longitudinal, in vivo investigation of postnatal skeletal development. This is the first paper using micro-CT to assess the reversibility of drug-induced bent long bones in a longitudinal study from birth to early adulthood in rat offspring. Analysis of the scans obtained on postnatal Day 0, 7, 21 and 80 showed complete recovery or repair of the bent long limb bones (including the scapula) within the first 3 weeks. When assessing risk the ability to demonstrate recovery is highly advantageous when interpreting such transient skeletal change. In summary, in vivo micro-CT of small laboratory animals can aid in non-clinical safety assessment, particularly for specific mechanistic purposes or to address a particular concern in developmental biology. Copyright © 2014 Elsevier Inc. All rights reserved.
Chen, Jianghao; Liu, Wei; Zhao, Jinxiu; Sun, Cong; Chen, Jie; Hu, Kaijin; Zhang, Linlin; Ding, Yuxiang
2017-03-01
To investigate the therapeutic effect of gelatin microspheres containing different concentrations of calcitonin gene-related peptide (CGRP) or substance P on repairing bone defects in a rabbit osteoporosis model. Gelatin microspheres containing different concentrations of CGRP or substance P promoted osteogenesis after 3 months in a rabbit osteoporotic bone defective model. From micro-computed tomography imaging results, 10 nM CGRP was optimal for increasing the trabecular number and decreasing the trabecular bone separation degree; similar effects were observed with the microspheres containing 1 µM substance P. Histological analysis showed that the gelatin microspheres containing CGRP or substance P, regardless of the concentration, effectively promoted osteogenesis, and the highest effect was achieved in the groups containing 1 µM CGRP or 1 µM substance P. Gelatin microspheres containing CGRP or substance P effectively promoted osteogenesis in a rabbit osteoporotic bone defect model dose-dependently, though their effects in repairing human alveolar ridge defects still need further investigation.
Yamaguchi, Shoki; Aoyama, Tomoki; Ito, Akira; Nagai, Momoko; Iijima, Hirotaka; Tajino, Junichi; Zhang, Xiangkai; Wataru, Kiyan; Kuroki, Hiroshi
2016-12-01
We investigated the effect of low-intensity pulsed ultrasound (LIPUS) treatment combined with mesenchymal stromal cell (MSC) injection for cartilage repair and subchondral bone reconstitution for treatment of osteochondral defects. An osteochondral defect was created on both femur grooves of Wistar rats. Four weeks later, bone marrow MSCs were injected into the right knee joint. The rats were divided into two intervention groups: without or with LIPUS irradiation. Cartilage repair was evaluated histologically based on the Wakitani cartilage repair score. Subchondral bone reconstitution was evaluated as bone volume (BV)/tissue volume (TV) by micro-computed tomography analysis. MSC injection improved the cartilage repair score, and LIPUS irradiation improved BV/TV. Combination treatment promoted both cartilage repair and BV/TV improvement. Thus, MSC injection combined with LIPUS irradiation is more effective than either treatment alone in promoting concurrent cartilage repair and subchondral reconstitution. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Bo; PLA General Hospital Cancer Center and PLA Cancer Research Institute, PLA Postgraduate School of Medicine, 28 Fuxing Road, Beijing; Dai, Jianxin
Highlight: • We first report that anti-osteopontin mAb could protect osteoporosis in mice. • Anti-osteopontin mAb could promote the osteoclast apoptosis. • Targeting osteopontin might have therapeutic potentials for osteoporosis. - Abstract: Osteopontin (OPN) is abundant in mineralized tissues and has long been implicated in bone remodeling. However, the therapeutic effect of targeting OPN in bone loss diseases and the underlying molecular mechanism remain largely unknown. Here, we reported that anti-OPN mAb (23C3) could protect against ovariectomy-induced osteoporosis in mice, demonstrated by microcomputed tomography analysis and histopathology evaluation. In vitro assay showed that 23C3 mAb reduced osteoclasts (OCs)-mediated bone resorptionmore » through promotion of mature OC apoptosis. Thus, the study has important implications for understanding the role of OPN in OC bone resorption and survival, and OPN antagonists may have therapeutic potential for osteoporosis and other osteopenic diseases.« less
NASA Technical Reports Server (NTRS)
Masuoka, E.; Rose, J.; Quattromani, M.
1981-01-01
Recent developments related to microprocessor-based personal computers have made low-cost digital image processing systems a reality. Image analysis systems built around these microcomputers provide color image displays for images as large as 256 by 240 pixels in sixteen colors. Descriptive statistics can be computed for portions of an image, and supervised image classification can be obtained. The systems support Basic, Fortran, Pascal, and assembler language. A description is provided of a system which is representative of the new microprocessor-based image processing systems currently on the market. While small systems may never be truly independent of larger mainframes, because they lack 9-track tape drives, the independent processing power of the microcomputers will help alleviate some of the turn-around time problems associated with image analysis and display on the larger multiuser systems.
Performance of hybrid system for fluorescence and micro-computed tomography in synchronous mode
NASA Astrophysics Data System (ADS)
Liu, Xin; Zhang, Yi; Liu, Fei; Guo, Xiaolian; Wang, Xin; Bai, Jing
2010-11-01
Fluorescence diffuse optical tomography (FDOT) plays an important role in studying physiological and pathological processes of small animals in vivo. The low spatial resolution, however, limits the ability of FDOT in resolving the biodistributions of fluorescent markers. The anatomical information provided by X-ray computed tomography (CT) can be used to improve the image quality of FDOT. However, in most hybrid FDOT/CT systems, the projection data sets of optics and X-ray are acquired sequentially, which increases the acquisition time and bring in the unwanted soft tissue displacement. In this paper, we evaluate the performance of a synchronous FDOT/CT system, which allows for faster and concurrent imaging. Compared with previous FDOT/CT systems, the two subsystems (FDOT and CT) acquire projection images in synchronous mode, so the body position can keep consistent in the same projection data acquired by both subsystems. The experimental results of phantom and in vivo experiments suggest that the reconstruction quality of FDOT can be significantly improved when structural a priori information is utilized to constrain the reconstruction process. On the other hand, the synchronous FDOT/CT system decreases the imaging time.
NASA Astrophysics Data System (ADS)
Xiao, Xianghui; Fusseis, Florian; De Carlo, Francesco
2012-10-01
State-of-art synchrotron radiation based micro-computed tomography provides high spatial and temporal resolution. This matches the needs of many research problems in geosciences. In this letter we report the current capabilities in microtomography at sector 2BM at the Advanced Photon Source (APS) of Argonne National Laboratory. The beamline is well suited to routinely acquire three-dimensional data of excellent quality with sub-micron resolution. Fast cameras in combination with a polychromatic beam allow time-lapse experiments with temporal resolutions of down to 200 ms. Data processing utilizes quantitative phase retrieval to optimize contrast in phase contrast tomographic data. The combination of these capabilities with purpose-designed experimental cells allows for a wide range of dynamic studies on geoscientific topics, two of which are summarized here. In the near future, new experimental cells capable of simulating conditions in most geological reservoirs will be available for general use. Ultimately, these advances will be matched by a new wide-field imaging beam line, which will be constructed as part of the APS upgrade. It is expected that even faster tomography with larger field of view can be conducted at this beam line, creating new opportunities for geoscientific studies.
Microcomputers in Transit: A Needs Assessment and Implementation Handbook. Final Report.
ERIC Educational Resources Information Center
Wyatt, Eve; Smerk, George
This handbook describes a practical step-by-step process for introducing microcomputers to small- and medium-sized transit operating agencies. The introductory chapter deals with the objective of buying a microcomputer system, the characteristics of microcomputers, microcomputer software, microcomputer system components, and issues faced in…
Scott, Anna E.; Vasilescu, Dragos M.; Seal, Katherine A. D.; Keyes, Samuel D.; Mavrogordato, Mark N.; Hogg, James C.; Sinclair, Ian; Warner, Jane A.; Hackett, Tillie-Louise; Lackie, Peter M.
2015-01-01
Background Understanding the three-dimensional (3-D) micro-architecture of lung tissue can provide insights into the pathology of lung disease. Micro computed tomography (µCT) has previously been used to elucidate lung 3D histology and morphometry in fixed samples that have been stained with contrast agents or air inflated and dried. However, non-destructive microstructural 3D imaging of formalin-fixed paraffin embedded (FFPE) tissues would facilitate retrospective analysis of extensive tissue archives of lung FFPE lung samples with linked clinical data. Methods FFPE human lung tissue samples (n = 4) were scanned using a Nikon metrology µCT scanner. Semi-automatic techniques were used to segment the 3D structure of airways and blood vessels. Airspace size (mean linear intercept, Lm) was measured on µCT images and on matched histological sections from the same FFPE samples imaged by light microscopy to validate µCT imaging. Results The µCT imaging protocol provided contrast between tissue and paraffin in FFPE samples (15mm x 7mm). Resolution (voxel size 6.7 µm) in the reconstructed images was sufficient for semi-automatic image segmentation of airways and blood vessels as well as quantitative airspace analysis. The scans were also used to scout for regions of interest, enabling time-efficient preparation of conventional histological sections. The Lm measurements from µCT images were not significantly different to those from matched histological sections. Conclusion We demonstrated how non-destructive imaging of routinely prepared FFPE samples by laboratory µCT can be used to visualize and assess the 3D morphology of the lung including by morphometric analysis. PMID:26030902
Willett, N J; Thote, T; Hart, M; Moran, S; Guldberg, R E; Kamath, R V
2016-09-01
The development of effective therapies for cartilage protection has been limited by a lack of efficient quantitative cartilage imaging modalities in pre-clinical in vivo models. Our objectives were two-fold: first, to validate a new contrast-enhanced 3D imaging analysis technique, equilibrium partitioning of an ionic contrast agent-micro computed tomography (EPIC-μCT), in a rat medial meniscal transection (MMT) osteoarthritis (OA) model; and second, to quantitatively assess the sensitivity of EPIC-μCT to detect the effects of matrix metalloproteinase inhibitor (MMPi) therapy on cartilage degeneration. Rats underwent MMT surgery and tissues were harvested at 1, 2, and 3 weeks post-surgery or rats received an MMPi or vehicle treatment and tissues harvested 3 weeks post-surgery. Parameters of disease progression were evaluated using histopathology and EPIC-μCT. Correlations and power analyses were performed to compare the techniques. EPIC-μCT was shown to provide simultaneous 3D quantification of multiple parameters, including cartilage degeneration and osteophyte formation. In MMT animals treated with MMPi, OA progression was attenuated, as measured by 3D parameters such as lesion volume and osteophyte size. A post-hoc power analysis showed that 3D parameters for EPIC-μCT were more sensitive than 2D parameters requiring fewer animals to detect a therapeutic effect of MMPi. 2D parameters were comparable between EPIC-μCT and histopathology. This study demonstrated that EPIC-μCT has high sensitivity to provide 3D structural and compositional measurements of cartilage and bone in the joint. EPIC-μCT can be used in combination with histology to provide a comprehensive analysis to screen new potential therapies. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.
NDE of Fiber Reinforced Foam Composite Structures for Future Aerospace Vehicles
NASA Technical Reports Server (NTRS)
Walker, james; Roth, Don; Hopkins, Dale
2010-01-01
This slide presentation reviews the complexities of non-destructive evaluation (NDE) of fiber reinforced foam composite structures to be used for aerospace vehicles in the future.Various views of fiber reinforced foam materials are shown and described. Conventional methods of NDE for composites are reviewed such as Micro-computed X-Ray Tomography, Thermography, Shearography, and Phased Array Ultrasonics (PAUT). These meth0ods appear to work well on the face sheet and face sheet ot core bond, they do not provide adequate coverage for the webs. There is a need for additional methods that will examine the webs and web to foam core bond.
Shalabi, Manal M; Wolke, Johannes G C; Cuijpers, Vincent M J I; Jansen, John A
2007-10-01
High-resolution three-dimensional data about the bone response to oral implants can be obtained by using microfocus computer tomography. However, a disadvantage is that metallic implants cause streaking artifacts due to scattering of X-rays, which prevents an accurate evaluation of the interfacial bone-to-implant contact. It has been suggested that the use of thin titanium coatings deposited on polymeric implants can offer an alternative option for analyzing bone contact using micro-CT imaging. Consequently, the aim of the current study was to investigate bone behavior to titanium-coated polymethylmethacrylate (PMMA) implants by micro-CT and histological evaluation. For the experiment titanium-coated PMMA implants were used. The implants had a machined threaded appearance and were provided with a 400-500 nm thick titanium coating. The implants were inserted in the right or left tibia of 10 goats. After an implantation period of 12 weeks the implants were retrieved and prepared for micro-computer tomography (microCT), light microscopy, and X-ray microanalysis. The micro-CT showed that the screw-threads and typical implant configuration were well maintained through the installation procedure. Overall, histological responses showed that the titanium-coated implants were well tolerated and caused no atypical tissue response. In addition, the bone was seen in direct contact with the titanium-coated layer. The X-ray microanalysis results confirmed the light microscopical data. In conclusion, the obtained results proof the final use of titanium-coated PMMA implants for evaluation of the bone-implant response using microCT. However, this study also confirms that for a proper analysis of the bone-implant interface the additional use of microscopical techniques is still required.
Accuracy of CBCT for volumetric measurement of simulated periapical lesions.
Ahlowalia, M S; Patel, S; Anwar, H M S; Cama, G; Austin, R S; Wilson, R; Mannocci, F
2013-06-01
To compare the accuracy of cone beam computed tomography (CBCT) and micro-computed tomography (μCT) when measuring the volume of bone cavities. Ten irregular-shaped cavities of varying dimensions were created in bovine bone specimens using a rotary diamond bur. The samples were then scanned using the Accuitomo 3D CBCT scanner. The scanned information was converted to the Digital Imaging and Communication in Medicine (DICOM) format ready for analysis. Once formatted, 10 trained and calibrated examiners segmented the scans and measured the volumes of the lesions. Intra/interexaminer agreement was assessed by each examiner re-segmenting each scan after a 2-week interval. Micro-CT scans were analysed by a single examiner. To achieve a physical reading of the artificially created cavities, replicas were created using dimensionally stable silicone impression material. After measuring the mass of each impression sample, the volume was calculated by dividing the mass of each sample by the density of the set impression material. Further corroboration of these measurements was obtained by employing Archimedes' principle to measure the volume of each impression sample. Intraclass correlation was used to assess agreement. Both CBCT (mean volume: 175.9 mm3) and μCT (mean volume: 163.1 mm3) showed a high degree of agreement (intraclass correlation coefficient >0.9) when compared to both weighed and 'Archimedes' principle' measurements (mean volume: 177.7 and 182.6 mm3, respectively). Cone beam computed tomography is an accurate means of measuring volume of artificially created bone cavities in an ex vivo model. This may provide a valuable tool for monitoring the healing rate of apical periodontitis; further investigations are warranted. © 2012 International Endodontic Journal. Published by Blackwell Publishing Ltd.
Geeslin, Andrew G; Jansson, Kyle S; Wijdicks, Coen A; Chapman, Mark A; Fok, Alex S; LaPrade, Robert F
2011-04-01
There is limited information in the literature on comparisons of antegrade versus retrograde reaming techniques and the effect on the creation of anterior cruciate ligament (ACL) tibial tunnel entry and exit apertures. Proximal and distal apertures of ACL tibial tunnels, as created with different reamers, will be affected by type of reamer design. Controlled laboratory study. Forty skeletally mature porcine tibias with bone mineral density values comparable with a young athletic population were included in this study. Five 9-mm reamer models were used (3 antegrade: A1, smooth-bore reamer; A2, acorn-head reamer; A3, flat-head reamer; 2 retrograde: R1, retrograde acorn reamer; R2, single-blade retrograde reamer), and a new reamer was used for each tibia (8 reamer-tibia pairs per reamer model). All specimens underwent micro-computed tomography scanning, and images were reconstructed and analyzed using 3-dimensional image analysis software. Aperture rim fractures were graded on a 0-IV scale that described the proportion of the fractured aperture circumference. Specimens with incomplete apertures were also recorded. Because of the unique characteristics of various tunnels, intratunnel characteristics were observed and recorded. In sum, 1 proximal and 7 distal aperture rim fractures were found; 3, 0, and 4 distal aperture rim fractures were found with groups A1, A2, and A3, respectively. Incomplete apertures were more commonly found at the distal aperture (n = 15) than the proximal aperture (n = 8); there were no tibias with this finding at both apertures. All incomplete distal apertures occurred with the retrograde technique, and all incomplete proximal apertures occurred with the antegrade technique, most commonly with reamer design A3. An added finding of tunnel curvature at the distal aspect of the tunnel was observed in all 8 tibias with R1 reamers and 5 tibias with R2 reamers. This phenomenon was not observed in any of the tibias reamed with the antegrade technique. Anterior cruciate ligament tibial tunnel aperture characteristics were highly dependent on reamer design. Optimal proximal aperture characteristics were produced by the retrograde reamers, whereas optimal distal aperture characteristics were obtained with the antegrade reamers. In addition, a phenomenon of tunnel curvature in retrograde-type reamers was found, which may have effects on ACL graft or screw fixation. Differences in tunnel aperture shapes and fractures depend on reamer design. This information is important for the creation of ACL reconstruction tunnels with different reamer designs.
Ballyns, Jeffery J; Gleghorn, Jason P; Niebrzydowski, Vicki; Rawlinson, Jeremy J; Potter, Hollis G; Maher, Suzanne A; Wright, Timothy M; Bonassar, Lawrence J
2008-07-01
This study demonstrates for the first time the development of engineered tissues based on anatomic geometries derived from widely used medical imaging modalities such as computed tomography (CT) and magnetic resonance imaging (MRI). Computer-aided design and tissue injection molding techniques have demonstrated the ability to generate living implants of complex geometry. Due to its complex geometry, the meniscus of the knee was used as an example of this technique's capabilities. MRI and microcomputed tomography (microCT) were used to design custom-printed molds that enabled the generation of anatomically shaped constructs that retained shape throughout 8 weeks of culture. Engineered constructs showed progressive tissue formation indicated by increases in extracellular matrix content and mechanical properties. The paradigm of interfacing tissue injection molding technology can be applied to other medical imaging techniques that render 3D models of anatomy, demonstrating the potential to apply the current technique to engineering of many tissues and organs.
Serefoglu, Burcu; Piskin, Beyser
2017-09-26
The aim of this investigation was to compare the cleaning and shaping efficiency of Self-adjusting file and Protaper, and to assess the correlation between root canal curvature and working time in mandibular molars using micro-computed tomography. Twenty extracted mandibular molars instrumented with Protaper and Self-adjusting file and the total working time was measured in mesial canals. The changes in canal volume, surface area and structure model index, transportation, uninstrumented area and the correlation between working-time and the curvature were analyzed. Although no statistically significant difference was observed between two systems in distal canals (p>0.05), a significantly higher amount of removed dentin volume and lower uninstrumented area were provided by Protaper in mesial canals (p<0.0001). A correlation between working-time and the canal-curvature was also observed in mesial canals for both groups (SAFr 2 =0.792, p<0.0004, PTUr 2 =0.9098, p<0.0001).
Quantification of eggshell microstructure using X-ray micro computed tomography
Riley, A.; Sturrock, C. J.; Mooney, S. J.
2014-01-01
1. X-ray microcomputed tomography can be used to produce rapid, fully analysable, three-dimensional images of biological and other materials without the need for complex or tedious sample preparation and sectioning. We describe the use of this technique to visualise and analyse the microstructure of fragments of shell taken from three regions of chicken eggs (sharp pole, blunt pole and equatorial region). 2. Two- and three-dimensional images and data were obtained at a resolution of 1.5 microns. The images were analysed to provide measurements of shell thickness, the spacial density of mammillary bodies, the frequency, shape, volume and effective diameter of individual pore spaces, and the intrinsic sponginess (proportion of non-X-ray dense material formed by vesicles) of the shell matrix. Measurements of these parameters were comparable with those derived by traditional methods and reported in the literature. 3. The advantages of using this technology for the quantification of eggshell microstructural parameters and its potential application for commercial, research and other purposes are discussed. PMID:24875292
NASA Astrophysics Data System (ADS)
Benoit, Julien; Jasinoski, Sandra C.; Fernandez, Vincent; Abdala, Fernando
2017-08-01
The basal non-mammaliaform cynodonts from the late Permian (Lopingian) and Early Triassic are a major source of information for the understanding of the evolutionary origin of mammals. Detailed knowledge of their anatomy is critical for understanding the phylogenetic transition toward mammalness and the paleobiological reconstruction of mammalian precursors. Using micro-computed tomography (μCT), we describe the internal morphology of the interorbital region that includes the rarely fossilized orbitosphenoid elements in four basal cynodonts. These paired bones, which are positioned relatively dorsally in the skull, contribute to the wall of the anterior part of the braincase and form the floor for the olfactory lobes. Unlike procynosuchids and the more basal therapsids in which the orbitosphenoids are well developed, dense, and bear a ventral keel, the basal epicynodonts Cynosaurus, Galesaurus, and Thrinaxodon display cancellous, reduced, and loosely articulated orbitosphenoids, a condition shared with many eucynodonts. The hemi-cylindrical orbitosphenoid from which the mammalian condition is derived re-evolved convergently in traversodontid and some probainognathian cynodonts.
Gold nanoparticle imaging and radiotherapy of brain tumors in mice
Hainfeld, James F; Smilowitz, Henry M; O'Connor, Michael J; Dilmanian, Farrokh Avraham; Slatkin, Daniel N
2013-01-01
Aim To test intravenously injected gold nanoparticles for x-ray imaging and radiotherapy enhancement of large, imminently lethal, intracerebral malignant gliomas. Materials & methods Gold nanoparticles approximately 11 nm in size were injected intravenously and brains imaged using microcomputed tomography. A total of 15 h after an intravenous dose of 4 g Au/kg was administered, brains were irradiated with 30 Gy 100 kVp x-rays. Results Gold uptake gave a 19:1 tumor-to-normal brain ratio with 1.5% w/w gold in tumor, calculated to increase local radiation dose by approximately 300%. Mice receiving gold and radiation (30 Gy) demonstrated 50% long term (>1 year) tumor-free survival, whereas all mice receiving radiation only died. Conclusion Intravenously injected gold nanoparticles cross the blood–tumor barrier, but are largely blocked by the normal blood–brain barrier, enabling high-resolution computed tomography tumor imaging. Gold radiation enhancement significantly improved long-term survival compared with radiotherapy alone. This approach holds promise to improve therapy of human brain tumors and other cancers. PMID:23265347
Kim, Sue Youn; Kim, Hyeon-Cheol; Shin, Su-Jung; Kim, Euiseong
2018-04-01
The purpose of this study was to evaluate the gap volume between dentin and root-end filling materials. Four root-end filling materials were compared in the present study: ProRoot MTA (PRM; Dentsply Tulsa Dental, Tulsa, OK), MTA Angelus (MAG; Angelus, Londrina, Brazil), EndoCem MTA (ECM; Maruchi, Wonju, Korea), and RetroMTA (RTM; BioMTA, Seoul, Korea). Forty-eight single-rooted, extracted human teeth were instrumented with nickel-titanium instruments and oburated with gutta-percha. The apical 3 mm of the root tip was resected, and root-end preparation was performed with a diamond bur. The root-end cavity was filled with the experimental filling materials for the 4 designated groups (n = 10). Then, the samples were scanned with micro-computed tomographic (micro-CT) imaging. Three-dimensional images of the samples were reconstructed, and the volume of the gap between the tooth surface (dentinal wall) and the root-end filling materials was measured. The percentage volume of the gap between the tooth structure and the root-end filling material (V G %) was calculated. Data were analyzed using the Kruskal-Wallis and Mann-Whitney U tests at a significance level of 95%. The median V G % values for the PRM, MAG, ECM, and RTM groups were 0.00472, 0.00134, 0.00014, and 0.00071, respectively. The ProRoot MTA group showed the greatest gap volume percentage among the experimental groups with a significant statistical difference (P < .05). From the micro-CT analysis, ProRoot MTA had a greater gap volume percentage than other root-end filling materials. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Feng, Sheng-Wei; Ho, Kuo-Ning; Chan, Ya-Hui; Chang, Kai-Jung; Lai, Wei-Yi; Huang, Haw-Ming
2016-12-01
The purpose of this study was to evaluate the possibility of using damping factor (DF) analysis to provide additional information on osseointegration of dental implants during the healing period. A total of 30 dental implants were installed in the bilateral femoral condyles of 15 rabbits. A DF analyzer detected with an impulse-forced vibration method and a commercialized dental implant stability analyzer based on resonance frequency (RF) analysis were used to measure the implant stability immediately after implant placement and 1, 2, 4, and 8 weeks post-surgically. Results of DF and RF analyses at different time points were compared with the corresponding osseointegration performance of dental implants via micro-computed tomography (micro-CT), histological and histomorphometrical analysis. The DF values revealed a decrease with time and reached 0.062 ± 0.007 at 8 weeks after implantation, which is almost 50% lower than the initial value. Moreover, highly significant correlations between DF values and bone volume densities (R 2 = 0.9797) and percentages of bone-to-implant contact measured at trabecular bone area (R 2 = 0.9773) were also observed. These results suggested that DF analysis combined with RF analysis results in a more sensitive assessment of changes in the dental implant/bone complex during the healing period than RF analysis alone.
Cohn Yakubovich, Doron; Tawackoli, Wafa; Sheyn, Dmitriy; Kallai, Ilan; Da, Xiaoyu; Pelled, Gadi; Gazit, Dan; Gazit, Zulma
2015-12-22
A major parameter determining the success of a bone-grafting procedure is vascularization of the area surrounding the graft. We hypothesized that implantation of a bone autograft would induce greater bone regeneration by abundant blood vessel formation. To investigate the effect of the graft on neovascularization at the defect site, we developed a micro-computed tomography (µCT) approach to characterize newly forming blood vessels, which involves systemic perfusion of the animal with a polymerizing contrast agent. This method enables detailed vascular analysis of an organ in its entirety. Additionally, blood perfusion was assessed using fluorescence imaging (FLI) of a blood-borne fluorescent agent. Bone formation was quantified by FLI using a hydroxyapatite-targeted probe and µCT analysis. Stem cell recruitment was monitored by bioluminescence imaging (BLI) of transgenic mice that express luciferase under the control of the osteocalcin promoter. Here we describe and demonstrate preparation of the allograft, calvarial defect surgery, µCT scanning protocols for the neovascularization study and bone formation analysis (including the in vivo perfusion of contrast agent), and the protocol for data analysis. The 3D high-resolution analysis of vasculature demonstrated significantly greater angiogenesis in animals with implanted autografts, especially with respect to arteriole formation. Accordingly, blood perfusion was significantly higher in the autograft group by the 7(th) day after surgery. We observed superior bone mineralization and measured greater bone formation in animals that received autografts. Autograft implantation induced resident stem cell recruitment to the graft-host bone suture, where the cells differentiated into bone-forming cells between the 7(th) and 10(th) postoperative day. This finding means that enhanced bone formation may be attributed to the augmented vascular feeding that characterizes autograft implantation. The methods depicted may serve as an optimal tool to study bone regeneration in terms of tightly bounded bone formation and neovascularization.
Hughes, Daniel F; Walker, Ellen M; Gignac, Paul M; Martinez, Anais; Negishi, Kenichiro; Lieb, Carl S; Greenbaum, Eli; Khan, Arshad M
2016-01-01
Biodiversity hotspots, which harbor more endemic species than elsewhere on Earth, are increasingly threatened. There is a need to accelerate collection efforts in these regions before threatened or endangered species become extinct. The diverse geographical, ecological, genetic, morphological, and behavioral data generated from the on-site collection of an individual specimen are useful for many scientific purposes. However, traditional methods for specimen preparation in the field do not permit researchers to retrieve neuroanatomical data, disregarding potentially useful data for increasing our understanding of brain diversity. These data have helped clarify brain evolution, deciphered relationships between structure and function, and revealed constraints and selective pressures that provide context about the evolution of complex behavior. Here, we report our field-testing of two commonly used laboratory-based techniques for brain preservation while on a collecting expedition in the Congo Basin and Albertine Rift, two poorly known regions associated with the Eastern Afromontane biodiversity hotspot. First, we found that transcardial perfusion fixation and long-term brain storage, conducted in remote field conditions with no access to cold storage laboratory equipment, had no observable impact on cytoarchitectural features of lizard brain tissue when compared to lizard brain tissue processed under laboratory conditions. Second, field-perfused brain tissue subjected to prolonged post-fixation remained readily compatible with subsequent immunohistochemical detection of neural antigens, with immunostaining that was comparable to that of laboratory-perfused brain tissue. Third, immersion-fixation of lizard brains, prepared under identical environmental conditions, was readily compatible with subsequent iodine-enhanced X-ray microcomputed tomography, which facilitated the non-destructive imaging of the intact brain within its skull. In summary, we have validated multiple approaches to preserving intact lizard brains in remote field conditions with limited access to supplies and a high degree of environmental exposure. This protocol should serve as a malleable framework for researchers attempting to rescue perishable and irreplaceable morphological and molecular data from regions of disappearing biodiversity. Our approach can be harnessed to extend the numbers of species being actively studied by the neuroscience community, by reducing some of the difficulty associated with acquiring brains of animal species that are not readily available in captivity.
Micro-computed tomography pore-scale study of flow in porous media: Effect of voxel resolution
NASA Astrophysics Data System (ADS)
Shah, S. M.; Gray, F.; Crawshaw, J. P.; Boek, E. S.
2016-09-01
A fundamental understanding of flow in porous media at the pore-scale is necessary to be able to upscale average displacement processes from core to reservoir scale. The study of fluid flow in porous media at the pore-scale consists of two key procedures: Imaging - reconstruction of three-dimensional (3D) pore space images; and modelling such as with single and two-phase flow simulations with Lattice-Boltzmann (LB) or Pore-Network (PN) Modelling. Here we analyse pore-scale results to predict petrophysical properties such as porosity, single-phase permeability and multi-phase properties at different length scales. The fundamental issue is to understand the image resolution dependency of transport properties, in order to up-scale the flow physics from pore to core scale. In this work, we use a high resolution micro-computed tomography (micro-CT) scanner to image and reconstruct three dimensional pore-scale images of five sandstones (Bentheimer, Berea, Clashach, Doddington and Stainton) and five complex carbonates (Ketton, Estaillades, Middle Eastern sample 3, Middle Eastern sample 5 and Indiana Limestone 1) at four different voxel resolutions (4.4 μm, 6.2 μm, 8.3 μm and 10.2 μm), scanning the same physical field of view. Implementing three phase segmentation (macro-pore phase, intermediate phase and grain phase) on pore-scale images helps to understand the importance of connected macro-porosity in the fluid flow for the samples studied. We then compute the petrophysical properties for all the samples using PN and LB simulations in order to study the influence of voxel resolution on petrophysical properties. We then introduce a numerical coarsening scheme which is used to coarsen a high voxel resolution image (4.4 μm) to lower resolutions (6.2 μm, 8.3 μm and 10.2 μm) and study the impact of coarsening data on macroscopic and multi-phase properties. Numerical coarsening of high resolution data is found to be superior to using a lower resolution scan because it avoids the problem of partial volume effects and reduces the scaling effect by preserving the pore-space properties influencing the transport properties. This is evidently compared in this study by predicting several pore network properties such as number of pores and throats, average pore and throat radius and coordination number for both scan based analysis and numerical coarsened data.
Yoshizawa, Sayuri; Chaya, Amy; Verdelis, Kostas; Bilodeau, Elizabeth A; Sfeir, Charles
2015-12-01
Magnesium (Mg) alloys have many unique qualities which make them ideal candidates for bone fixation devices, including biocompatibility and degradation in vivo. Despite a rise in Mg alloy production and research, there remains no standardized system to assess their degradation or biological effect on human stem cells in vivo. In this study, we developed a novel in vivo model to assess Mg alloys for craniofacial and orthopedic applications. Our model consists of a collagen sponge seeded with human bone marrow stromal cells (hBMSCs) around a central Mg alloy rod. These scaffolds were implanted subcutaneously in mice and analyzed after eight weeks. Alloy degradation and biological effect were determined by microcomputed tomography (microCT), histological staining, and immunohistochemistry (IHC). MicroCT showed greater volume loss for pure Mg compared to AZ31 after eight weeks in vivo. Histological analysis showed that hBMSCs were retained around the Mg implants after 8 weeks. Furthermore, immunohistochemistry showed the expression of dentin matrix protein 1 and osteopontin around both pure Mg and AZ31 with implanted hBMSCs. In addition, histological sections showed a thin mineral layer around all degrading alloys at the alloy-tissue interface. In conclusion, our data show that degrading pure Mg and AZ31 implants are cytocompatible and do not inhibit the osteogenic property of hBMSCs in vivo. These results demonstrate that this model can be used to efficiently assess the biological effect of corroding Mg alloys in vivo. Importantly, this model may be modified to accommodate additional cell types and clinical applications. Magnesium (Mg) alloys have been investigated as ideal candidates for bone fixation devices due to high biocompatibility and degradation in vivo, and there is a growing need of establishing an efficient in vivo material screening system. In this study, we assessed degradation rate and biological effect of Mg alloys by transplanting Mg alloy rod with human bone marrow stromal cells seeded on collagen sponge subcutaneously in mice. After 8 weeks, samples were analyzed by microcomputed tomography and histological staining. Our data show that degrading Mg alloys are cytocompatible and do not inhibit the osteogenic property of hBMSCs in vivo. These results demonstrate that this model can be used to efficiently assess the biological effect of corroding Mg alloys in vivo. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Hughes, Daniel F.; Walker, Ellen M.; Gignac, Paul M.; Martinez, Anais; Negishi, Kenichiro; Lieb, Carl S.; Greenbaum, Eli
2016-01-01
Biodiversity hotspots, which harbor more endemic species than elsewhere on Earth, are increasingly threatened. There is a need to accelerate collection efforts in these regions before threatened or endangered species become extinct. The diverse geographical, ecological, genetic, morphological, and behavioral data generated from the on-site collection of an individual specimen are useful for many scientific purposes. However, traditional methods for specimen preparation in the field do not permit researchers to retrieve neuroanatomical data, disregarding potentially useful data for increasing our understanding of brain diversity. These data have helped clarify brain evolution, deciphered relationships between structure and function, and revealed constraints and selective pressures that provide context about the evolution of complex behavior. Here, we report our field-testing of two commonly used laboratory-based techniques for brain preservation while on a collecting expedition in the Congo Basin and Albertine Rift, two poorly known regions associated with the Eastern Afromontane biodiversity hotspot. First, we found that transcardial perfusion fixation and long-term brain storage, conducted in remote field conditions with no access to cold storage laboratory equipment, had no observable impact on cytoarchitectural features of lizard brain tissue when compared to lizard brain tissue processed under laboratory conditions. Second, field-perfused brain tissue subjected to prolonged post-fixation remained readily compatible with subsequent immunohistochemical detection of neural antigens, with immunostaining that was comparable to that of laboratory-perfused brain tissue. Third, immersion-fixation of lizard brains, prepared under identical environmental conditions, was readily compatible with subsequent iodine-enhanced X-ray microcomputed tomography, which facilitated the non-destructive imaging of the intact brain within its skull. In summary, we have validated multiple approaches to preserving intact lizard brains in remote field conditions with limited access to supplies and a high degree of environmental exposure. This protocol should serve as a malleable framework for researchers attempting to rescue perishable and irreplaceable morphological and molecular data from regions of disappearing biodiversity. Our approach can be harnessed to extend the numbers of species being actively studied by the neuroscience community, by reducing some of the difficulty associated with acquiring brains of animal species that are not readily available in captivity. PMID:27196138
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xie, Tianwu; Zaidi, Habib, E-mail: habib.zaidi@hcuge.ch; Geneva Neuroscience Center, Geneva University, Geneva CH-1205
The development of multimodality preclinical imaging techniques and the rapid growth of realistic computer simulation tools have promoted the construction and application of computational laboratory animal models in preclinical research. Since the early 1990s, over 120 realistic computational animal models have been reported in the literature and used as surrogates to characterize the anatomy of actual animals for the simulation of preclinical studies involving the use of bioluminescence tomography, fluorescence molecular tomography, positron emission tomography, single-photon emission computed tomography, microcomputed tomography, magnetic resonance imaging, and optical imaging. Other applications include electromagnetic field simulation, ionizing and nonionizing radiation dosimetry, and themore » development and evaluation of new methodologies for multimodality image coregistration, segmentation, and reconstruction of small animal images. This paper provides a comprehensive review of the history and fundamental technologies used for the development of computational small animal models with a particular focus on their application in preclinical imaging as well as nonionizing and ionizing radiation dosimetry calculations. An overview of the overall process involved in the design of these models, including the fundamental elements used for the construction of different types of computational models, the identification of original anatomical data, the simulation tools used for solving various computational problems, and the applications of computational animal models in preclinical research. The authors also analyze the characteristics of categories of computational models (stylized, voxel-based, and boundary representation) and discuss the technical challenges faced at the present time as well as research needs in the future.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kazakia,G.; Burghardt, A.; Cheung, S.
2008-01-01
Assessment of bone tissue mineral density (TMD) may provide information critical to the understanding of mineralization processes and bone biomechanics. High-resolution three-dimensional assessment of TMD has recently been demonstrated using synchrotron radiation microcomputed tomography (SR{mu}CT); however, this imaging modality is relatively inaccessible due to the scarcity of SR facilities. Conventional desktop {mu}CT systems are widely available and have been used extensively to assess bone microarchitecture. However, the polychromatic source and cone-shaped beam geometry complicate assessment of TMD by conventional {mu}CT. The goal of this study was to evaluate {mu}CT-based measurement of degree and distribution of tissue mineralization in a quantitative,more » spatially resolved manner. Specifically, {mu}CT measures of bone mineral content (BMC) and TMD were compared to those obtained by SR{mu}CT and gravimetric methods. Cylinders of trabecular bone were machined from human femoral heads (n=5), vertebrae (n=5), and proximal tibiae (n=4). Cylinders were imaged in saline on a polychromatic {mu}CT system at an isotropic voxel size of 8 {mu}m. Volumes were reconstructed using beam hardening correction algorithms based on hydroxyapatite (HA)-resin wedge phantoms of 200 and 1200 mgHA/cm3. SR{mu}CT imaging was performed at an isotropic voxel size of 7.50 {mu}m at the National Synchrotron Light Source. Attenuation values were converted to HA concentration using a linear regression derived by imaging a calibration phantom. Architecture and mineralization parameters were calculated from the image data. Specimens were processed using gravimetric methods to determine ash mass and density. {mu}CT-based BMC values were not affected by altering the beam hardening correction. Volume-averaged TMD values calculated by the two corrections were significantly different (p=0.008) in high volume fraction specimens only, with the 1200 mgHA/cm3 correction resulting in a 4.7% higher TMD value. {mu}CT and SR{mu}CT provided significantly different measurements of both BMC and TMD (p<0.05). In high volume fraction specimens, {mu}CT with 1200 mgHA/cm3 correction resulted in BMC and TMD values 16.7% and 15.0% lower, respectively, than SR{mu}CT values. In low volume fraction specimens, {mu}CT with 1200 mgHA/cm3 correction resulted in BMC and TMD values 12.8% and 12.9% lower, respectively, than SR{mu}CT values. {mu}CT and SR{mu}CT values were well-correlated when volume fraction groups were considered individually (BMC R2=0.97-1.00; TMD R2=0.78-0.99). Ash mass and density were higher than the SR{mu}CT equivalents by 8.6% in high volume fraction specimens and 10.9% in low volume fraction specimens (p<0.05). BMC values calculated by tomography were highly correlated with ash mass (ash versus {mu}CT R2=0.96-1.00; ash versus SR{mu}CT R2=0.99-1.00). TMD values calculated by tomography were moderately correlated with ash density (ash versus {mu}CT R2=0.64-0.72; ash versus SR{mu}CT R2=0.64). Spatially resolved comparisons highlighted substantial geometric nonuniformity in the {mu}CT data, which were reduced (but not eliminated) using the 1200 mg HA/cm3 beam hardening correction, and did not exist in the SR{mu}CT data. This study represents the first quantitative comparison of {mu}CT mineralization evaluation against SR{mu}CT and gravimetry. Our results indicate that {mu}CT mineralization measures are underestimated but well-correlated with SR{mu}CT and gravimetric data, particularly when volume fraction groups are considered individually.« less
Kazakia, G. J.; Burghardt, A. J.; Cheung, S.; Majumdar, S.
2008-01-01
Assessment of bone tissue mineral density (TMD) may provide information critical to the understanding of mineralization processes and bone biomechanics. High-resolution three-dimensional assessment of TMD has recently been demonstrated using synchrotron radiation microcomputed tomography (SRμCT); however, this imaging modality is relatively inaccessible due to the scarcity of SR facilities. Conventional desktop μCT systems are widely available and have been used extensively to assess bone microarchitecture. However, the polychromatic source and cone-shaped beam geometry complicate assessment of TMD by conventional μCT. The goal of this study was to evaluate μCT-based measurement of degree and distribution of tissue mineralization in a quantitative, spatially resolved manner. Specifically, μCT measures of bone mineral content (BMC) and TMD were compared to those obtained by SRμCT and gravimetric methods. Cylinders of trabecular bone were machined from human femoral heads (n=5), vertebrae (n=5), and proximal tibiae (n=4). Cylinders were imaged in saline on a polychromatic μCT system at an isotropic voxel size of 8 μm. Volumes were reconstructed using beam hardening correction algorithms based on hydroxyapatite (HA)-resin wedge phantoms of 200 and 1200 mg HA∕cm3. SRμCT imaging was performed at an isotropic voxel size of 7.50 μm at the National Synchrotron Light Source. Attenuation values were converted to HA concentration using a linear regression derived by imaging a calibration phantom. Architecture and mineralization parameters were calculated from the image data. Specimens were processed using gravimetric methods to determine ash mass and density. μCT-based BMC values were not affected by altering the beam hardening correction. Volume-averaged TMD values calculated by the two corrections were significantly different (p=0.008) in high volume fraction specimens only, with the 1200 mg HA∕cm3 correction resulting in a 4.7% higher TMD value. μCT and SRμCT provided significantly different measurements of both BMC and TMD (p<0.05). In high volume fraction specimens, μCT with 1200 mg HA∕cm3 correction resulted in BMC and TMD values 16.7% and 15.0% lower, respectively, than SRμCT values. In low volume fraction specimens, μCT with 1200 mg HA∕cm3 correction resulted in BMC and TMD values 12.8% and 12.9% lower, respectively, than SRμCT values. μCT and SRμCT values were well-correlated when volume fraction groups were considered individually (BMC R2=0.97−1.00; TMD R2=0.78−0.99). Ash mass and density were higher than the SRμCT equivalents by 8.6% in high volume fraction specimens and 10.9% in low volume fraction specimens (p<0.05). BMC values calculated by tomography were highly correlated with ash mass (ash versus μCT R2=0.96−1.00; ash versus SRμCT R2=0.99−1.00). TMD values calculated by tomography were moderately correlated with ash density (ash versus μCT R2=0.64−0.72; ash versus SRμCT R2=0.64). Spatially resolved comparisons highlighted substantial geometric nonuniformity in the μCT data, which were reduced (but not eliminated) using the 1200 mg HA∕cm3 beam hardening correction, and did not exist in the SRμCT data. This study represents the first quantitative comparison of μCT mineralization evaluation against SRμCT and gravimetry. Our results indicate that μCT mineralization measures are underestimated but well-correlated with SRμCT and gravimetric data, particularly when volume fraction groups are considered individually. PMID:18697542
New generation of exploration tools: interactive modeling software and microcomputers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krajewski, S.A.
1986-08-01
Software packages offering interactive modeling techniques are now available for use on microcomputer hardware systems. These packages are reasonably priced for both company and independent explorationists; they do not require users to have high levels of computer literacy; they are capable of rapidly completing complex ranges of sophisticated geologic and geophysical modeling tasks; and they can produce presentation-quality output for comparison with real-world data. For example, interactive packages are available for mapping, log analysis, seismic modeling, reservoir studies, and financial projects as well as for applying a variety of statistical and geostatistical techniques to analysis of exploration data. More importantly,more » these packages enable explorationists to directly apply their geologic expertise when developing and fine-tuning models for identifying new prospects and for extending producing fields. As a result of these features, microcomputers and interactive modeling software are becoming common tools in many exploration offices. Gravity and magnetics software programs illustrate some of the capabilities of such exploration tools.« less
Quantitative analysis of titanium-induced artifacts and correlated factors during micro-CT scanning.
Li, Jun Yuan; Pow, Edmond Ho Nang; Zheng, Li Wu; Ma, Li; Kwong, Dora Lai Wan; Cheung, Lim Kwong
2014-04-01
To investigate the impact of cover screw, resin embedment, and implant angulation on artifact of microcomputed tomography (micro-CT) scanning for implant. A total of twelve implants were randomly divided into 4 groups: (i) implant only; (ii) implant with cover screw; (iii) implant with resin embedment; and (iv) implants with cover screw and resin embedment. Implants angulation at 0°, 45°, and 90° were scanned by micro-CT. Images were assessed, and the ratio of artifact volume to total volume (AV/TV) was calculated. A multiple regression analysis in stepwise model was used to determine the significance of different factors. One-way ANOVA was performed to identify which combination of factors could minimize the artifact. In the regression analysis, implant angulation was identified as the best predictor for artifact among the factors (P < 0.001). Resin embedment also had significant effect on artifact volume (P = 0.028), while cover screw had not (P > 0.05). Non-embedded implants with the axis parallel to X-ray source of micro-CT produced minimal artifact. Implant angulation and resin embedment affected the artifact volume of micro-CT scanning for implant, while cover screw did not. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Statistical analysis of magnetically soft particles in magnetorheological elastomers
NASA Astrophysics Data System (ADS)
Gundermann, T.; Cremer, P.; Löwen, H.; Menzel, A. M.; Odenbach, S.
2017-04-01
The physical properties of magnetorheological elastomers (MRE) are a complex issue and can be influenced and controlled in many ways, e.g. by applying a magnetic field, by external mechanical stimuli, or by an electric potential. In general, the response of MRE materials to these stimuli is crucially dependent on the distribution of the magnetic particles inside the elastomer. Specific knowledge of the interactions between particles or particle clusters is of high relevance for understanding the macroscopic rheological properties and provides an important input for theoretical calculations. In order to gain a better insight into the correlation between the macroscopic effects and microstructure and to generate a database for theoretical analysis, x-ray micro-computed tomography (X-μCT) investigations as a base for a statistical analysis of the particle configurations were carried out. Different MREs with quantities of 2-15 wt% (0.27-2.3 vol%) of iron powder and different allocations of the particles inside the matrix were prepared. The X-μCT results were edited by an image processing software regarding the geometrical properties of the particles with and without the influence of an external magnetic field. Pair correlation functions for the positions of the particles inside the elastomer were calculated to statistically characterize the distributions of the particles in the samples.
MicroCT angiography detects vascular formation and regression in skin wound healing.
Urao, Norifumi; Okonkwo, Uzoagu A; Fang, Milie M; Zhuang, Zhen W; Koh, Timothy J; DiPietro, Luisa A
2016-07-01
Properly regulated angiogenesis and arteriogenesis are essential for effective wound healing. Tissue injury induces robust new vessel formation and subsequent vessel maturation, which involves vessel regression and remodeling. Although formation of functional vasculature is essential for healing, alterations in vascular structure over the time course of skin wound healing are not well understood. Here, using high-resolution ex vivo X-ray micro-computed tomography (microCT), we describe the vascular network during healing of skin excisional wounds with highly detailed three-dimensional (3D) reconstructed images and associated quantitative analysis. We found that relative vessel volume, surface area and branching number are significantly decreased in wounds from day 7 to days 14 and 21. Segmentation and skeletonization analysis of selected branches from high-resolution images as small as 2.5μm voxel size show that branching orders are decreased in the wound vessels during healing. In histological analysis, we found that the contrast agent fills mainly arterioles, but not small capillaries nor large veins. In summary, high-resolution microCT revealed dynamic alterations of vessel structures during wound healing. This technique may be useful as a key tool in the study of the formation and regression of wound vessels. Copyright © 2016 Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Fosdick, Howard
1980-01-01
Examines the development of the microcomputer and focuses on its potential for library automation. The characteristics of microcomputers and minicomputers are contrasted and a selected annotated bibliography includes a list of specialty magazines on microcomputers. (RAA)
Noninvasive imaging of experimental lung fibrosis.
Zhou, Yong; Chen, Huaping; Ambalavanan, Namasivayam; Liu, Gang; Antony, Veena B; Ding, Qiang; Nath, Hrudaya; Eary, Janet F; Thannickal, Victor J
2015-07-01
Small animal models of lung fibrosis are essential for unraveling the molecular mechanisms underlying human fibrotic lung diseases; additionally, they are useful for preclinical testing of candidate antifibrotic agents. The current end-point measures of experimental lung fibrosis involve labor-intensive histological and biochemical analyses. These measures fail to account for dynamic changes in the disease process in individual animals and are limited by the need for large numbers of animals for longitudinal studies. The emergence of noninvasive imaging technologies provides exciting opportunities to image lung fibrosis in live animals as often as needed and to longitudinally track the efficacy of novel antifibrotic compounds. Data obtained by noninvasive imaging provide complementary information to histological and biochemical measurements. In addition, the use of noninvasive imaging in animal studies reduces animal usage, thus satisfying animal welfare concerns. In this article, we review these new imaging modalities with the potential for evaluation of lung fibrosis in small animal models. Such techniques include micro-computed tomography (micro-CT), magnetic resonance imaging, positron emission tomography (PET), single photon emission computed tomography (SPECT), and multimodal imaging systems including PET/CT and SPECT/CT. It is anticipated that noninvasive imaging will be increasingly used in animal models of fibrosis to gain insights into disease pathogenesis and as preclinical tools to assess drug efficacy.
Warger, William C.; Hostens, Jeroen; Namati, Eman; Birngruber, Reginald; Bouma, Brett E.; Tearney, Guillermo J.
2012-01-01
Abstract. Optical coherence tomography (OCT) has been increasingly used for imaging pulmonary alveoli. Only a few studies, however, have quantified individual alveolar areas, and the validity of alveolar volumes represented within OCT images has not been shown. To validate quantitative measurements of alveoli from OCT images, we compared the cross-sectional area, perimeter, volume, and surface area of matched subpleural alveoli from microcomputed tomography (micro-CT) and OCT images of fixed air-filled swine samples. The relative change in size between different alveoli was extremely well correlated (r>0.9, P<0.0001), but OCT images underestimated absolute sizes compared to micro-CT by 27% (area), 7% (perimeter), 46% (volume), and 25% (surface area) on average. We hypothesized that the differences resulted from refraction at the tissue–air interfaces and developed a ray-tracing model that approximates the reconstructed alveolar size within OCT images. Using this model and OCT measurements of the refractive index for lung tissue (1.41 for fresh, 1.53 for fixed), we derived equations to obtain absolute size measurements of superellipse and circular alveoli with the use of predictive correction factors. These methods and results should enable the quantification of alveolar sizes from OCT images in vivo. PMID:23235834
NASA Astrophysics Data System (ADS)
Unglert, Carolin I.; Warger, William C.; Hostens, Jeroen; Namati, Eman; Birngruber, Reginald; Bouma, Brett E.; Tearney, Guillermo J.
2012-12-01
Optical coherence tomography (OCT) has been increasingly used for imaging pulmonary alveoli. Only a few studies, however, have quantified individual alveolar areas, and the validity of alveolar volumes represented within OCT images has not been shown. To validate quantitative measurements of alveoli from OCT images, we compared the cross-sectional area, perimeter, volume, and surface area of matched subpleural alveoli from microcomputed tomography (micro-CT) and OCT images of fixed air-filled swine samples. The relative change in size between different alveoli was extremely well correlated (r>0.9, P<0.0001), but OCT images underestimated absolute sizes compared to micro-CT by 27% (area), 7% (perimeter), 46% (volume), and 25% (surface area) on average. We hypothesized that the differences resulted from refraction at the tissue-air interfaces and developed a ray-tracing model that approximates the reconstructed alveolar size within OCT images. Using this model and OCT measurements of the refractive index for lung tissue (1.41 for fresh, 1.53 for fixed), we derived equations to obtain absolute size measurements of superellipse and circular alveoli with the use of predictive correction factors. These methods and results should enable the quantification of alveolar sizes from OCT images in vivo.
Simulation analysis of a microcomputer-based, low-cost Omega navigation system
NASA Technical Reports Server (NTRS)
Lilley, R. W.; Salter, R. J., Jr.
1976-01-01
The current status of research on a proposed micro-computer-based, low-cost Omega Navigation System (ONS) is described. The design approach emphasizes minimum hardware, maximum software, and the use of a low-cost, commercially-available microcomputer. Currently under investigation is the implementation of a low-cost navigation processor and its interface with an omega sensor to complete the hardware-based ONS. Sensor processor functions are simulated to determine how many of the sensor processor functions can be handled by innovative software. An input data base of live Omega ground and flight test data was created. The Omega sensor and microcomputer interface modules used to collect the data are functionally described. Automatic synchronization to the Omega transmission pattern is described as an example of the algorithms developed using this data base.
An Extended Microcomputer-Based Network Optimization Package.
1982-10-01
Analysis, Laxenberq, Austria, 1981, pp. 781-808. 9. Anton , H., Elementary Linear Algebra , John Wiley & Sons, New York, 1977. 10. Koopmans, T. C...fCaRUlue do leVee. aide It 001100"M OW eedea9f’ OF Nooke~e Network, generalized network, microcomputer, optimization, network with gains, linear ...Oboe &111111041 network problem, in turn, can be viewed as a specialization of a linear programuing problem having at most two non-zero entries in each
Impacts-BRC (below regulatory concern): The microcomputer version
DOE Office of Scientific and Technical Information (OSTI.GOV)
Campbell, J.E.; O'Neal, B.L.
1989-01-01
The IMPACTS-BRC computer code was designed for use by the Nuclear Regulatory Commission and industry to evaluate petitions to classify specific waste streams as below regulatory concern (BRC). The code provides a capability for calculating radiation doses to a maximal individual, critical group, and the general population as a result of transportation, treatment, disposal, and post-disposal activities involving low level radioactive waste. Since IMPACTS-BRC is expected to be widely used, the code has been adapted for use on a microcomputer. The microcomputer version of the code provides several features that simplify its use and broaden its applicability. These features includemore » (1) a menu-driven environment, (2) an input editor to simplify creation and editing of input files, (3) default input values and help screens to guide the user in analyzing a particular problem, (4) the ability to perform both parametric studies and Monte Carlo analysis to examine uncertainties, and (5) interactive graphics and statistics output. This paper describes the microcomputer version of IMPACTS-BRC and illustrates its use through an example application. 5 refs., 5 figs., 3 tabs.« less
Duan, Yuanyuan; Chandran, Ravi; Cherry, Denise
The purpose of this study was to create three-dimensional composite models of quad zygomatic implant-supported maxillary prostheses with a variety of alveolar bone defects around implant sites, and to investigate the stress distribution in the surrounding bone using the finite element analysis (FEA) method. Three-dimensional models of titanium zygomatic implants, maxillary prostheses, and human skulls were created and assembled using Mimics based on microcomputed tomography and cone beam computed tomography images. A variety of additional bone defects were created at the locations of four zygomatic implants to simulate multiple clinical scenarios. The volume meshes were created and exported into FEA software. Material properties were assigned respectively for all the structures, and von Mises stress data were collected and plotted in the postprocessing module. The maximum stress in the surrounding bone was located in the crestal bone around zygomatic implants. The maximum stress in the prostheses was located at the angled area of the implant-abutment connection. The model with anterior defects had a higher peak stress value than the model with posterior defects. All the models with additional bone defects had higher maximum stress values than the control model without additional bone loss. Additional alveolar bone loss has a negative influence on the stress concentration in the surrounding bone of quad zygomatic implant-supported prostheses. More care should be taken if these additional bone defects are at the sites of anterior zygomatic implants.
Pan, Hsin Chuan; Lee, Soonchul; Ting, Kang; Shen, Jia; Wang, Chenchao; Nguyen, Alan; Berthiaume, Emily A; Zara, Janette N; Turner, A Simon; Seim, Howard B; Kwak, Jin Hee; Zhang, Xinli; Soo, Chia
2017-07-01
Multiple case reports using recombinant human bone morphogenetic protein-2 (rhBMP-2) have reported complications. However, the local adverse effects of rhBMP-2 application are not well documented. In this report we show that, in addition to promoting lumbar spinal fusion through potent osteogenic effects, rhBMP-2 augmentation promotes local cyst-like osteolytic formations in sheep trabecular bones that have undergone anterior lumbar interbody fusion. Three months after operation, conventional computed tomography showed that the trabecular bones of the rhBMP-2 application groups could fuse, whereas no fusion was observed in the control group. Micro-computed tomography analysis revealed that the core implant area's bone volume fraction and bone mineral density increased proportionately with rhBMP-2 dose. Multiple cyst-like bone voids were observed in peri-implant areas when using rhBMP-2 applications, and these sites showed significant bone mineral density decreases in relation to the unaffected regions. Biomechanically, these areas decreased in strength by 32% in comparison with noncystic areas. Histologically, rhBMP-2-affected void sites had an increased amount of fatty marrow, thinner trabecular bones, and significantly more adiponectin- and cathepsin K-positive cells. Despite promoting successful fusion, rhBMP-2 use in clinical applications may result in local adverse structural alterations and compromised biomechanical changes to the bone. Copyright © 2017 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.
Yin, Xingzhe; Cheung, Gary Shun-Pan; Zhang, Chengfei; Masuda, Yoshiko Murakami; Kimura, Yuichi; Matsumoto, Koukichi
2010-04-01
The purpose of this study was to assess the efficacy of instrumentation of C-shaped canals with ProTaper rotary system and traditional instruments by using micro-computed tomography (micro-CT). Twenty-four mandibular molars with C-shaped canals were selected in pairs and sorted equally into 2 groups, which were assigned for instrumentation by ProTaper rotary system (ProTaper group) or by K-files and Gates-Glidden burs (Hand Instrument group). Three-dimensional images were constructed by micro-CT. The volume of dentin removed, uninstrumented canal area, time taken for instrumentation, and iatrogenic error of instrumentation were investigated. Hand Instrument group showed greater amount of volumetric dentin removal and left less uninstrumented canal area than ProTaper group (P < .01). The time needed for instrumentation was shorter for ProTaper group than for Hand Instrument group (P < .05). No instrument breakage occurred in both groups, but more conspicuous procedural errors were detected in Hand Instrument group than for ProTaper group. It was concluded that ProTaper rotary system maintained the canal curvature with speediness and few procedural errors, whereas traditional instrumentation can clean more canal surface. Copyright (c) 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Douglas, Timothy E L; Schietse, Josefien; Zima, Aneta; Gorodzha, Svetlana; Parakhonskiy, Bogdan V; KhaleNkow, Dmitry; Shkarin, Roman; Ivanova, Anna; Baumbach, Tilo; Weinhardt, Venera; Stevens, Christian V; Vanhoorne, Valérie; Vervaet, Chris; Balcaen, Lieve; Vanhaecke, Frank; Slośarczyk, Anna; Surmeneva, Maria A; Surmenev, Roman A; Skirtach, Andre G
2018-03-01
Mineralized hydrogels are increasingly gaining attention as biomaterials for bone regeneration. The most common mineralization strategy has been addition of preformed inorganic particles during hydrogel formation. This maintains injectability. One common form of bone cement is formed by mixing particles of the highly reactive calcium phosphate alpha-tricalcium phosphate (α-TCP) with water to form hydroxyapatite (HA). The calcium ions released during this reaction can be exploited to crosslink anionic, calcium-binding polymers such as the polysaccharide gellan gum (GG) to induce hydrogel formation. In this study, three different amounts of α-TCP particles were added to GG polymer solution to generate novel, injectable hydrogel-inorganic composites. Distribution of the inorganic phase in the hydrogel was studied by high resolution microcomputer tomography (µCT). Gelation occurred within 30 min. α-TCP converted to HA. µCT revealed inhomogeneous distribution of the inorganic phase in the composites. These results demonstrate the potential of the composites as alternatives to traditional α-TCP bone cement and pave the way for incorporation of biologically active substances and in vitro and in vivo testing. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 106A: 822-828, 2018. © 2017 Wiley Periodicals, Inc.
Restrain of bone growth by estrogen-mimetic peptide-1 (EMP-1): a micro-computed tomographic study.
Kasher, Roni; Bajayo, Alon; Gabet, Yankel; Nevo, Nava; Fridkin, Mati; Katchalski-Katzir, Ephraim; Kohen, Fortune; Bab, Itai
2009-06-01
Estrogen has a key role in the regulation of skeletal growth and maintenance of bone mass. Recently, we developed peptides having estrogen-like activity as potential estrogen-based new drugs. The aim of the present study was to evaluate the influence of long-term administration of the most efficacious of these peptides, the hexapeptide EMP-1 (VSWFFE), on bone mass and development. EMP-1 was injected daily to ovariectomized (OVX) and intact young, sexually mature female mice for 10 weeks. Whole femora, including the cartilaginous growth plates were analyzed by micro-computed tomography (microCT). We found that peptide EMP-1 restrains bone growth in OVX mice: it inhibited dramatically bone longitudinal growth (40%), and decreased femoral diaphyseal diameter. Peptide EMP-1 had no effect on bone growth in normal mice, and did not influence the OVX-induced bone loss. We then developed a new microCT methodology to evaluate uncalcified and calcified growth plate parameters. In the OVX mice, peptide EMP-1 reduced volume and thickness of the uncalcified growth plate, a possible cause for the inhibition of bone longitudinal growth. Peptide EMP-1 may be used as a lead compound for the development of drugs to treat acromegalic patients.
NASA Astrophysics Data System (ADS)
Johri, Ansh; Schimel, Daniel; Noguchi, Audrey; Hsu, Lewis L.
2010-03-01
Imaging is a crucial clinical tool for diagnosis and assessment of pneumonia, but quantitative methods are lacking. Micro-computed tomography (micro CT), designed for lab animals, provides opportunities for non-invasive radiographic endpoints for pneumonia studies. HYPOTHESIS: In vivo micro CT scans of mice with early bacterial pneumonia can be scored quantitatively by semiautomated imaging methods, with good reproducibility and correlation with bacterial dose inoculated, pneumonia survival outcome, and radiologists' scores. METHODS: Healthy mice had intratracheal inoculation of E. coli bacteria (n=24) or saline control (n=11). In vivo micro CT scans were performed 24 hours later with microCAT II (Siemens). Two independent radiologists scored the extent of airspace abnormality, on a scale of 0 (normal) to 24 (completely abnormal). Using the Amira 5.2 software (Mercury Computer Systems), a histogram distribution of voxel counts between the Hounsfield range of -510 to 0 was created and analyzed, and a segmentation procedure was devised. RESULTS: A t-test was performed to determine whether there was a significant difference in the mean voxel value of each mouse in the three experimental groups: Saline Survivors, Pneumonia Survivors, and Pneumonia Non-survivors. It was found that the voxel count method was able to statistically tell apart the Saline Survivors from the Pneumonia Survivors, the Saline Survivors from the Pneumonia Non-survivors, but not the Pneumonia Survivors vs. Pneumonia Non-survivors. The segmentation method, however, was successfully able to distinguish the two Pneumonia groups. CONCLUSION: We have pilot-tested an evaluation of early pneumonia in mice using micro CT and a semi-automated method for lung segmentation and scoring system. Statistical analysis indicates that the system is reliable and merits further evaluation.
Tu, Shu-Ju; Wang, Shun-Ping; Cheng, Fu-Chou; Weng, Chia-En; Huang, Wei-Tzu; Chang, Wei-Jeng; Chen, Ying-Ju
2017-01-01
The literature shows that bone mineral density (BMD) and the geometric architecture of trabecular bone in the femur may be affected by inadequate dietary intake of Mg. In this study, we used microcomputed tomography (micro-CT) to characterize and quantify the impact of a low-Mg diet on femoral trabecular bones in mice. Four-week-old C57BL/6J male mice were randomly assigned to 2 groups and supplied either a normal or low-Mg diet for 8weeks. Samples of plasma and urine were collected for biochemical analysis, and femur tissues were removed for micro-CT imaging. In addition to considering standard parameters, we regarded trabecular bone as a cylindrical rod and used computational algorithms for a technical assessment of the morphological characteristics of the bones. BMD (mg-HA/cm3) was obtained using a standard phantom. We observed a decline in the total tissue volume, bone volume, percent bone volume, fractal dimension, number of trabecular segments, number of connecting nodes, bone mineral content (mg-HA), and BMD, as well as an increase in the structural model index and surface-area-to-volume ratio in low-Mg mice. Subsequently, we examined the distributions of the trabecular segment length and radius, and a series of specific local maximums were identified. The biochemical analysis revealed a 43% (96%) decrease in Mg and a 40% (71%) decrease in Ca in plasma (urine excretion). This technical assessment performed using micro-CT revealed a lower population of femoral trabecular bones and a decrease in BMD at the distal metaphysis in the low-Mg mice. Examining the distributions of the length and radius of trabecular segments showed that the average length and radius of the trabecular segments in low-Mg mice are similar to those in normal mice.
Microprocessors as a Vehicle for Teaching Circuit Analysis.
ERIC Educational Resources Information Center
Neu, Emil C.
1982-01-01
Based on the premise that most engineering students will own their own microcomputers, discusses the teaching of circuit analysis, possible directions to be taken in hardware analysis, and impact on the mathematics related to circuit analysis. (SK)
A Protocol for Bioinspired Design: A Ground Sampler Based on Sea Urchin Jaws
Frank, Michael B.; Naleway, Steven E.; Wirth, Taylor S.; Jung, Jae-Young; Cheung, Charlene L.; Loera, Faviola B.; Medina, Sandra; Sato, Kirk N.; Taylor, Jennifer R. A.; McKittrick, Joanna
2016-01-01
Bioinspired design is an emerging field that takes inspiration from nature to develop high-performance materials and devices. The sea urchin mouthpiece, known as the Aristotle's lantern, is a compelling source of bioinspiration with an intricate network of musculature and calcareous teeth that can scrape, cut, chew food and bore holes into rocky substrates. We describe the bioinspiration process as including animal observation, specimen characterization, device fabrication and mechanism bioexploration. The last step of bioexploration allows for a deeper understanding of the initial biology. The design architecture of the Aristotle's lantern is analyzed with micro-computed tomography and individual teeth are examined with scanning electron microscopy to identify the microstructure. Bioinspired designs are fabricated with a 3D printer, assembled and tested to determine the most efficient lantern opening and closing mechanism. Teeth from the bioinspired lantern design are bioexplored via finite element analysis to explain from a mechanical perspective why keeled tooth structures evolved in the modern sea urchins we observed. This circular approach allows for new conclusions to be drawn from biology and nature. PMID:27166636
Amber fossils demonstrate deep-time stability of Caribbean lizard communities
Sherratt, Emma; del Rosario Castañeda, María; Garwood, Russell J.; Mahler, D. Luke; Sanger, Thomas J.; Herrel, Anthony; de Queiroz, Kevin; Losos, Jonathan B.
2015-01-01
Whether the structure of ecological communities can exhibit stability over macroevolutionary timescales has long been debated. The similarity of independently evolved Anolis lizard communities on environmentally similar Greater Antillean islands supports the notion that community evolution is deterministic. However, a dearth of Caribbean Anolis fossils—only three have been described to date—has precluded direct investigation of the stability of anole communities through time. Here we report on an additional 17 fossil anoles in Dominican amber dating to 15–20 My before the present. Using data collected primarily by X-ray microcomputed tomography (X-ray micro-CT), we demonstrate that the main elements of Hispaniolan anole ecomorphological diversity were in place in the Miocene. Phylogenetic analysis yields results consistent with the hypothesis that the ecomorphs that evolved in the Miocene are members of the same ecomorph clades extant today. The primary axes of ecomorphological diversity in the Hispaniolan anole fauna appear to have changed little between the Miocene and the present, providing evidence for the stability of ecological communities over macroevolutionary timescales. PMID:26216976
Effect of Resorbable Collagen Plug on Bone Regeneration in Rat Critical-Size Defect Model.
Liu, Weiqing; Kang, Ning; Dong, Yuliang; Guo, Yuchen; Zhao, Dan; Zhang, Shiwen; Zhou, Liyan; Seriwatanachai, Dutmanee; Liang, Xing; Yuan, Quan
2016-04-01
The purpose of this investigation was to examine the effect of resorbable collagen plug (RCP) on bone regeneration in rat calvarial critical-size defects. About 5-mm-diameter calvarial defects were created in forty 12-week-old male Sprague-Dawley rats and implanted with or without RCP. Animals were killed at 1, 2, 4, and 8 weeks postoperatively. After being killed, specimens were collected and subjected to micro-computed tomography (μCT) and histological analysis. The μCT showed a significant increase of newly formed bone volume/tissue volume in RCP-implanted defect compared with controls at all designated time points. After 8 weeks, the defects implanted with RCP displayed almost complete closure. Hematoxylin and eosin staining of the decalcified sections confirmed these observations and evidenced active bone regeneration in the RCP group. In addition, Masson's trichrome staining demonstrated that RCP implantation accelerated the process of collagen maturation. The RCP enhances bone regeneration in rat critical-size cranial defects, which suggest it might be a desired material for bone defect repair.
Three-scale analysis of the permeability of a natural shale
NASA Astrophysics Data System (ADS)
Davy, C. A.; Adler, P. M.
2017-12-01
The macroscopic permeability of a natural shale is determined by using structural measurements on three different scales. Transmission electron microscopy yields two-dimensional (2D) images with pixels smaller than 1 nm; these images are used to reconstruct 3D nanostructures. Three-dimensional focused ion beam-scanning electron microscopy (5.95- to 8.48-nm voxel size) provides 3D mesoscale pores of limited relative volume (1.71-5.9%). Micro-computed tomography (700-nm voxel size) provides information on the mineralogy of the shale, including the pores on this scale which do not percolate; synthetic 3D media are derived on the macroscopic scale by a training image technique. Permeability of the nanoscale, of the mesoscale structures and of their superposition is determined by solving the Stokes equation and this enables us to estimate the permeabilities of the 700-nm voxels located within the clay matrix. Finally, the Darcy equation is solved on synthetic 3D macroscale media to obtain the macroscopic permeability which is found in good agreement with experimental results obtained on the centimetric scale.
Effects of Active Mastication on Chronic Stress-Induced Bone Loss in Mice
Azuma, Kagaku; Furuzawa, Manabu; Fujiwara, Shu; Yamada, Kumiko; Kubo, Kin-ya
2015-01-01
Chronic psychologic stress increases corticosterone levels, which decreases bone density. Active mastication or chewing attenuates stress-induced increases in corticosterone. We evaluated whether active mastication attenuates chronic stress-induced bone loss in mice. Male C57BL/6 (B6) mice were randomly divided into control, stress, and stress/chewing groups. Stress was induced by placing mice in a ventilated restraint tube (60 min, 2x/day, 4 weeks). The stress/chewing group was given a wooden stick to chew during the experimental period. Quantitative micro-computed tomography, histologic analysis, and biochemical markers were used to evaluate the bone response. The stress/chewing group exhibited significantly attenuated stress-induced increases in serum corticosterone levels, suppressed bone formation, enhanced bone resorption, and decreased trabecular bone mass in the vertebrae and distal femurs, compared with mice in the stress group. Active mastication during exposure to chronic stress alleviated chronic stress-induced bone density loss in B6 mice. Active mastication during chronic psychologic stress may thus be an effective strategy to prevent and/or treat chronic stress-related osteopenia. PMID:26664256
Effects of Active Mastication on Chronic Stress-Induced Bone Loss in Mice.
Azuma, Kagaku; Furuzawa, Manabu; Fujiwara, Shu; Yamada, Kumiko; Kubo, Kin-ya
2015-01-01
Chronic psychologic stress increases corticosterone levels, which decreases bone density. Active mastication or chewing attenuates stress-induced increases in corticosterone. We evaluated whether active mastication attenuates chronic stress-induced bone loss in mice. Male C57BL/6 (B6) mice were randomly divided into control, stress, and stress/chewing groups. Stress was induced by placing mice in a ventilated restraint tube (60 min, 2x/day, 4 weeks). The stress/chewing group was given a wooden stick to chew during the experimental period. Quantitative micro-computed tomography, histologic analysis, and biochemical markers were used to evaluate the bone response. The stress/chewing group exhibited significantly attenuated stress-induced increases in serum corticosterone levels, suppressed bone formation, enhanced bone resorption, and decreased trabecular bone mass in the vertebrae and distal femurs, compared with mice in the stress group. Active mastication during exposure to chronic stress alleviated chronic stress-induced bone density loss in B6 mice. Active mastication during chronic psychologic stress may thus be an effective strategy to prevent and/or treat chronic stress-related osteopenia.
Visualizing 3D Food Microstructure Using Tomographic Methods: Advantages and Disadvantages.
Wang, Zi; Herremans, Els; Janssen, Siem; Cantre, Dennis; Verboven, Pieter; Nicolaï, Bart
2018-03-25
X-ray micro-computed tomography (micro-CT) provides the unique ability to capture intact internal microstructure data without significant preparation of the sample. The fundamentals of micro-CT technology are briefly described along with a short introduction to basic image processing, quantitative analysis, and derivative computational modeling. The applications and limitations of micro-CT in industries such as meat, dairy, postharvest, and bread/confectionary are discussed to serve as a guideline to the plausibility of utilizing the technique for detecting features of interest. Component volume fractions, their respective size/shape distributions, and connectivity, for example, can be utilized for product development, manufacturing process tuning and/or troubleshooting. In addition to determining structure-function relations, micro-CT can be used for foreign material detection to further ensure product quality and safety. In most usage scenarios, micro-CT in its current form is perfectly adequate for determining microstructure in a wide variety of food products. However, in low-contrast and low-stability samples, emphasis is placed on the shortcomings of the current systems to set realistic expectations for the intended users.
ERIC Educational Resources Information Center
Snaden, James N.; And Others
Geographers in the United States rely heavily on microcomputers. They employ microcomputers to enhance three general categories of tasks: word processing and other productivity needs, geographic instruction, and discipline-specific applications. Word processing and desktop publishing continue to be the primary uses of microcomputers by…
Wang, Zhiwei; Chen, Huanxiong; Yu, Y. Eric; Zhang, Jiajun; Cheuk, Ka-Yee; Ng, Bobby K. W.; Qiu, Yong; Guo, X. Edward; Cheng, Jack C. Y.; Lee, Wayne Y. W.
2017-01-01
Adolescent idiopathic scoliosis is a complex disease with unclear etiopathogenesis. Systemic and persistent low bone mineral density is an independent prognostic factor for curve progression. The fundamental question of how bone quality is affected in AIS remains controversy because there is lack of site-matched control for detailed analysis on bone-related parameters. In this case-control study, trabecular bone biopsies from iliac crest were collected intra-operatively from 28 severe AIS patients and 10 matched controls with similar skeletal and sexual maturity, anthropometry and femoral neck BMD Z-score to control confounding effects. In addition to static histomorphometry, micro-computed tomography (μCT) and real time-PCR (qPCR) analyses, individual trabecula segmentation (ITS)-based analysis, finite element analysis (FEA), energy dispersive X-ray spectroscopy (EDX) were conducted to provide advanced analysis of structural, mechanical and mineralization features. μCT and histomorphometry showed consistently reduced trabecular number and connectivity. ITS revealed predominant change in trabecular rods, and EDX confirmed less mineralization. The structural and mineralization abnormality led to slight reduction in apparent modulus, which could be attributed to differential down-regulation of Runx2, and up-regulation of Spp1 and TRAP. In conclusion, this is the first comprehensive study providing direct evidence of undefined unique pathological changes at different bone hierarchical levels in AIS. PMID:28054655
Chang, Po-Chun; Seol, Yang-Jo; Goldstein, Steven A.; Giannobile, William V.
2014-01-01
Purpose It is currently a challenge to determine the biomechanical properties of the hard tissue–dental implant interface. Recent advances in intraoral imaging and tomographic methods, such as microcomputed tomography (micro-CT), provide three-dimensional details, offering significant potential to evaluate the bone-implant interface, but yield limited information regarding osseointegration because of physical scattering effects emanating from metallic implant surfaces. In the present study, it was hypothesized that functional apparent moduli (FAM), generated from functional incorporation of the peri-implant structure, would eliminate the radiographic artifact–affected layer and serve as a feasible means to evaluate the biomechanical dynamics of tissue-implant integration in vivo. Materials and Methods Cylindric titanium mini-implants were placed in osteotomies and osteotomies with defects in rodent maxillae. The layers affected by radiographic artifacts were identified, and the pattern of tissue-implant integration was evaluated from histology and micro-CT images over a 21-day observation period. Analyses of structural information, FAM, and the relationship between FAM and interfacial stiffness (IS) were done before and after eliminating artifacts. Results Physical artifacts were present within a zone of about 100 to 150 μm around the implant in both experimental defect situations (osteotomy alone and osteotomy + defect). All correlations were evaluated before and after eliminating the artifact-affected layers, most notably during the maturation period of osseointegration. A strong correlation existed between functional bone apparent modulus and IS within 300 μm at the osteotomy defects (r > 0.9) and functional composite tissue apparent modulus in the osteotomy defects (r > 0.75). Conclusion Micro-CT imaging and FAM were of value in measuring the temporal process of tissue-implant integration in vivo. This approach will be useful to complement imaging technologies for longitudinal monitoring of osseointegration. PMID:23377049
Li, Zihui; Kuhn, Gisela; Schirmer, Michael; Müller, Ralph; Ruffoni, Davide
2017-01-01
Although osteoporotic bone, with low bone mass and deteriorated bone architecture, provides a less favorable mechanical environment than healthy bone for implant fixation, there is no general agreement on the impact of osteoporosis on peri-implant bone (re)modeling, which is ultimately responsible for the long term stability of the bone-implant system. Here, we inserted an implant in a mouse model mimicking estrogen deficiency-induced bone loss and we monitored with longitudinal in vivo micro-computed tomography the spatio-temporal changes in bone (re)modeling and architecture, considering the separate contributions of trabecular, endocortical and periosteal surfaces. Specifically, 12 week-old C57BL/6J mice underwent OVX/SHM surgery; 9 weeks after we inserted special metal-ceramics implants into the 6th caudal vertebra and we measured bone response with in vivo micro-CT weekly for the following 6 weeks. Our results indicated that ovariectomized mice showed a reduced ability to increase the thickness of the cortical shell close to the implant because of impaired peri-implant bone formation, especially at the periosteal surface. Moreover, we observed that healthy mice had a significantly higher loss of trabecular bone far from the implant than estrogen depleted animals. Such behavior suggests that, in healthy mice, the substantial increase in peri-implant bone formation which rapidly thickened the cortex to secure the implant may raise bone resorption elsewhere and, specifically, in the trabecular network of the same bone but far from the implant. Considering the already deteriorated bone structure of estrogen depleted mice, further bone loss seemed to be hindered. The obtained knowledge on the dynamic response of diseased bone following implant insertion should provide useful guidelines to develop advanced treatments for osteoporotic fracture fixation based on local and selective manipulation of bone turnover in the peri-implant region.
Li, Zihui; Kuhn, Gisela; Schirmer, Michael; Müller, Ralph
2017-01-01
Although osteoporotic bone, with low bone mass and deteriorated bone architecture, provides a less favorable mechanical environment than healthy bone for implant fixation, there is no general agreement on the impact of osteoporosis on peri-implant bone (re)modeling, which is ultimately responsible for the long term stability of the bone-implant system. Here, we inserted an implant in a mouse model mimicking estrogen deficiency-induced bone loss and we monitored with longitudinal in vivo micro-computed tomography the spatio-temporal changes in bone (re)modeling and architecture, considering the separate contributions of trabecular, endocortical and periosteal surfaces. Specifically, 12 week-old C57BL/6J mice underwent OVX/SHM surgery; 9 weeks after we inserted special metal-ceramics implants into the 6th caudal vertebra and we measured bone response with in vivo micro-CT weekly for the following 6 weeks. Our results indicated that ovariectomized mice showed a reduced ability to increase the thickness of the cortical shell close to the implant because of impaired peri-implant bone formation, especially at the periosteal surface. Moreover, we observed that healthy mice had a significantly higher loss of trabecular bone far from the implant than estrogen depleted animals. Such behavior suggests that, in healthy mice, the substantial increase in peri-implant bone formation which rapidly thickened the cortex to secure the implant may raise bone resorption elsewhere and, specifically, in the trabecular network of the same bone but far from the implant. Considering the already deteriorated bone structure of estrogen depleted mice, further bone loss seemed to be hindered. The obtained knowledge on the dynamic response of diseased bone following implant insertion should provide useful guidelines to develop advanced treatments for osteoporotic fracture fixation based on local and selective manipulation of bone turnover in the peri-implant region. PMID:28910363
Vetsch, Jolanda Rita; Betts, Duncan Colin; Müller, Ralph; Hofmann, Sandra
2017-01-01
Mechanical loading plays a major role in bone remodeling and fracture healing. Mimicking the concept of mechanical loading of bone has been widely studied in bone tissue engineering by perfusion cultures. Nevertheless, there is still debate regarding the in-vitro mechanical stimulation regime. This study aims at investigating the effect of two different flow rates (vlow = 0.001m/s and vhigh = 0.061m/s) on the growth of mineralized tissue produced by human mesenchymal stromal cells cultured on 3-D silk fibroin scaffolds. The flow rates applied were chosen to mimic the mechanical environment during early fracture healing or during bone remodeling, respectively. Scaffolds cultured under static conditions served as a control. Time-lapsed micro-computed tomography showed that mineralized extracellular matrix formation was completely inhibited at vlow compared to vhigh and the static group. Biochemical assays and histology confirmed these results and showed enhanced osteogenic differentiation at vhigh whereas the amount of DNA was increased at vlow. The biological response at vlow might correspond to the early stage of fracture healing, where cell proliferation and matrix production is prominent. Visual mapping of shear stresses, simulated by computational fluid dynamics, to 3-D micro-computed tomography data revealed that shear stresses up to 0.39mPa induced a higher DNA amount and shear stresses between 0.55mPa and 24mPa induced osteogenic differentiation. This study demonstrates the feasibility to drive cell behavior of human mesenchymal stromal cells by the flow velocity applied in agreement with mechanical loading mimicking early fracture healing (vlow) or bone remodeling (vhigh). These results can be used in the future to tightly control the behavior of human mesenchymal stromal cells towards proliferation or differentiation. Additionally, the combination of experiment and simulation presented is a strong tool to link biological responses to mechanical stimulation and can be applied to various in-vitro cultures to improve the understanding of the cause-effect relationship of mechanical loading.
Luo, S; Yang, X; Wang, D; Ni, J; Wu, J; Xu, Z; Xuan, D; Zhang, J
2016-08-01
Periodontitis has been associated with type 2 diabetes mellitus. We investigated the effects of local aberrant secretion of adipokines in diabetic rats on systemic metabolism. Otsuka Long-Evans Tokushima Fatty (OLETF) and non-diabetic Long-Evans Tokushima Otsuka rats were used as a diabetic model and associated control, respectively. Periodontitis was induced using a silk ligature for 36 wk. Rats were grouped into OLETF with (OP+) or without (OP-) periodontitis and Long-Evans Tokushima Otsuka with (LP+) or without (LP-) periodontitis. Alveolar bone resorption and destruction were evaluated by micro-computed tomography and hematoxylin and eosin staining. After 20 wk of periodontitis induction, lipids, insulin, interleukin-1, leptin and plasminogen activator inhibitor-1 were analyzed, and mRNA expressions of NF-κB, Mark8, TLR2 and -4, IKBKB and Nampt were evaluated by quantitative polymerase chain reaction in adipose tissue. After ligation, OLETF rats exhibited typical periodontitis lesions with the clinical features of type 2 diabetes mellitus. When compared with the OP(-) group, the area under curve of the oral glucose tolerance test and homeostatic model assessment-insulin resistance values were significantly higher in the OP(+) group. Micro-computed tomography showed that the OP(+) group had more bone resorption than the OP(-) group. When compared with the OP(-) group, the OP(+) group also exhibited higher total cholesterol (p < 0.05), leptin (p < 0.05), insulin (p > 0.05) and higher expression of Nampt (p < 0.05) and IKBKB (p < 0.05). The LP(+) group had a trend towards higher bone resorption when compared with the LP(-) group. Additionally, no difference in white adipose tissues or adipokines was found between LP(+) and LP(-) rats. Chronic periodontitis can alter lipid profiles in affected rats, elevate adipose tissue expression of Nampt and affect the metabolism of adipose tissue through the NF-κB pathway to inflame diabetes. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Douglas, Timothy E L; Dziadek, Michal; Gorodzha, Svetlana; Lišková, Jana; Brackman, Gilles; Vanhoorne, Valérie; Vervaet, Chris; Balcaen, Lieve; Del Rosario Florez Garcia, Maria; Boccaccini, Aldo R; Weinhardt, Venera; Baumbach, Tilo; Vanhaecke, Frank; Coenye, Tom; Bačáková, Lucie; Surmeneva, Maria A; Surmenev, Roman A; Cholewa-Kowalska, Katarzyna; Skirtach, Andre G
2018-06-01
Mineralization of hydrogel biomaterials is desirable to improve their suitability as materials for bone regeneration. In this study, gellan gum (GG) hydrogels were formed by simple mixing of GG solution with bioactive glass microparticles of 45S5 composition, leading to hydrogel formation by ion release from the amorphous bioactive glass microparticles. This resulted in novel injectable, self-gelling composites of GG hydrogels containing 20% bioactive glass. Gelation occurred within 20 min. Composites containing the standard 45S5 bioactive glass preparation were markedly less stiff. X-ray microcomputed tomography proved to be a highly sensitive technique capable of detecting microparticles of diameter approximately 8 μm, that is, individual microparticles, and accurately visualizing the size distribution of bioactive glass microparticles and their aggregates, and their distribution in GG hydrogels. The widely used melt-derived 45S5 preparation served as a standard and was compared with a calcium-rich, sol-gel derived preparation (A2), as well as A2 enriched with zinc (A2Zn5) and strontium (A2Sr5). A2, A2Zn, and A2Sr bioactive glass particles were more homogeneously dispersed in GG hydrogels than 45S5. Composites containing all four bioactive glass preparations exhibited antibacterial activity against methicillin-resistant Staphylococcus aureus. Composites containing A2Zn5 and A2Sr5 bioactive glasses supported the adhesion and growth of osteoblast-like cells and were considerably more cytocompatible than 45S5. All composites underwent mineralization with calcium-deficient hydroxyapatite upon incubation in simulated body fluid. The extent of mineralization appeared to be greatest for composites containing A2Zn5 and 45S5. The results underline the importance of the choice of bioactive glass when preparing injectable, self-gelling composites. Copyright © 2018 John Wiley & Sons, Ltd.
Barak, Shlomo; Neuman, Moshe; Iezzi, Giovanna; Piattelli, Adriano; Perrotti, Vittoria; Gabet, Yankel
2016-08-01
In the present study, a new healing cap that could generate a pulsed electromagnetic field (PEMF) around titanium implants to stimulate peri-implant osteogenesis was tested in the rabbit model. A total of 22 implants were inserted in the proximal tibial metaphysis of 22 rabbits. A healing cap containing the active device was inserted in half of the implants (11 test implants); an "empty" healing cap was inserted in the other ones (11 control implants). The animals were euthanized after 2 and 4 weeks, and the samples were processed for micro-computed tomography and histology. The peri-implant volume was divided into coronal (where the PEMF was the strongest) and apical regions. Most of the effects of the tested device were confined to the coronal region. Two weeks post-implantation, test implants showed a significant 56% higher trabecular bone fraction (BV/TV), associated with enhanced trabecular number (Tb.N, +37%) and connectivity density (Conn.D, +73%) as compared to the control group; at 4 weeks, the PEMF induced a 69% increase in BV/TV and 34% increase of Tb.N. There was no difference in the trabecular thickness (Tb.Th) at either time point. Furthermore, we observed a 48% higher bone-to-implant contact (BIC) in the test implants vs. controls after 2 weeks; this increase tended to remain stable until the fourth week. Mature trabecular and woven bone were observed in direct contact with the implant surface with no gaps or connective tissue at the bone-implant interface. These results indicate that the PEMF device stimulated early bone formation around dental implants resulting in higher peri-implant BIC and bone mass already after 2 weeks which suggests an acceleration of the osseointegration process by more than three times. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Mineral distributions at the developing tendon enthesis.
Schwartz, Andrea G; Pasteris, Jill D; Genin, Guy M; Daulton, Tyrone L; Thomopoulos, Stavros
2012-01-01
Tendon attaches to bone across a functionally graded interface, "the enthesis". A gradient of mineral content is believed to play an important role for dissipation of stress concentrations at mature fibrocartilaginous interfaces. Surgical repair of injured tendon to bone often fails, suggesting that the enthesis does not regenerate in a healing setting. Understanding the development and the micro/nano-meter structure of this unique interface may provide novel insights for the improvement of repair strategies. This study monitored the development of transitional tissue at the murine supraspinatus tendon enthesis, which begins postnatally and is completed by postnatal day 28. The micrometer-scale distribution of mineral across the developing enthesis was studied by X-ray micro-computed tomography and Raman microprobe spectroscopy. Analyzed regions were identified and further studied by histomorphometry. The nanometer-scale distribution of mineral and collagen fibrils at the developing interface was studied using transmission electron microscopy (TEM). A zone (∼20 µm) exhibiting a gradient in mineral relative to collagen was detected at the leading edge of the hard-soft tissue interface as early as postnatal day 7. Nanocharacterization by TEM suggested that this mineral gradient arose from intrinsic surface roughness on the scale of tens of nanometers at the mineralized front. Microcomputed tomography measurements indicated increases in bone mineral density with time. Raman spectroscopy measurements revealed that the mineral-to-collagen ratio on the mineralized side of the interface was constant throughout postnatal development. An increase in the carbonate concentration of the apatite mineral phase over time suggested possible matrix remodeling during postnatal development. Comparison of Raman-based observations of localized mineral content with histomorphological features indicated that development of the graded mineralized interface is linked to endochondral bone formation near the tendon insertion. These conserved and time-varying aspects of interface composition may have important implications for the growth and mechanical stability of the tendon-to-bone attachment throughout development.
Hann, Cheryl R.; Bentley, Michael D.; Vercnocke, Andrew; Ritman, Erik L.; Fautsch, Michael P.
2011-01-01
The site of outflow resistance leading to elevated intraocular pressure in primary open angle glaucoma is believed to be located in the region of Schlemm’s canal inner wall endothelium, its basement membrane and the adjacent juxtacanalicular tissue. Evidence also suggests collector channels and intrascleral vessels may have a role in intraocular pressure in both normal and glaucoma eyes. Traditional imaging modalities limit the ability to view both proximal and distal portions of the trabecular outflow pathway as a single unit. In this study, we examined the effectiveness of three-dimensional micro-computed tomography (3D micro-CT) as a potential method to view the trabecular outflow pathway. Two normal human eyes were used: one immersion fixed in 4% paraformaldehyde, and one with anterior chamber perfusion at 10 mmHg followed by perfusion fixation in 4% paraformaldehyde/2% glutaraldehyde. Both eyes were postfixed in 1% osmium tetroxide, and scanned with 3D micro-CT at 2 µm or 5 µm voxel resolution. In the immersion fixed eye, 24 collector channels were identified with an average orifice size of 27.5 ± 5 µm. In comparison, the perfusion fixed eye had 29 collector channels with a mean orifice size of 40.5 ± 13 µm. Collector channels were not evenly dispersed around the circumference of the eye. There was no significant difference in the length of Schlemm’s canal in the immersed versus the perfused eye (33.2 versus 35.1 mm). Structures, locations and size measurements identified by 3D micro-CT were confirmed by correlative light microscopy. These findings confirm 3D micro-CT can be used effectively for the non-invasive examination of the trabecular meshwork, Schlemm’s canal, collector channels and intrascleral vasculature that comprise the distal outflow pathway. This imaging modality will be useful for noninvasive study of the role of the trabecular outflow pathway as a whole unit. PMID:21187085
DOE Office of Scientific and Technical Information (OSTI.GOV)
C Hann; M Bentley; A Vercnocke
2011-12-31
The site of outflow resistance leading to elevated intraocular pressure in primary open-angle glaucoma is believed to be located in the region of Schlemm's canal inner wall endothelium, its basement membrane and the adjacent juxtacanalicular tissue. Evidence also suggests collector channels and intrascleral vessels may have a role in intraocular pressure in both normal and glaucoma eyes. Traditional imaging modalities limit the ability to view both proximal and distal portions of the trabecular outflow pathway as a single unit. In this study, we examined the effectiveness of three-dimensional micro-computed tomography (3D micro-CT) as a potential method to view the trabecularmore » outflow pathway. Two normal human eyes were used: one immersion fixed in 4% paraformaldehyde and one with anterior chamber perfusion at 10 mmHg followed by perfusion fixation in 4% paraformaldehyde/2% glutaraldehyde. Both eyes were postfixed in 1% osmium tetroxide and scanned with 3D micro-CT at 2 {mu}m or 5 {mu}m voxel resolution. In the immersion fixed eye, 24 collector channels were identified with an average orifice size of 27.5 {+-} 5 {mu}m. In comparison, the perfusion fixed eye had 29 collector channels with a mean orifice size of 40.5 {+-} 13 {mu}m. Collector channels were not evenly dispersed around the circumference of the eye. There was no significant difference in the length of Schlemm's canal in the immersed versus the perfused eye (33.2 versus 35.1 mm). Structures, locations and size measurements identified by 3D micro-CT were confirmed by correlative light microscopy. These findings confirm 3D micro-CT can be used effectively for the non-invasive examination of the trabecular meshwork, Schlemm's canal, collector channels and intrascleral vasculature that comprise the distal outflow pathway. This imaging modality will be useful for non-invasive study of the role of the trabecular outflow pathway as a whole unit.« less
NASA Astrophysics Data System (ADS)
Ning, Nannan; Tian, Jie; Liu, Xia; Deng, Kexin; Wu, Ping; Wang, Bo; Wang, Kun; Ma, Xibo
2014-02-01
In mathematics, optical molecular imaging including bioluminescence tomography (BLT), fluorescence tomography (FMT) and Cerenkov luminescence tomography (CLT) are concerned with a similar inverse source problem. They all involve the reconstruction of the 3D location of a single/multiple internal luminescent/fluorescent sources based on 3D surface flux distribution. To achieve that, an accurate fusion between 2D luminescent/fluorescent images and 3D structural images that may be acquired form micro-CT, MRI or beam scanning is extremely critical. However, the absence of a universal method that can effectively convert 2D optical information into 3D makes the accurate fusion challengeable. In this study, to improve the fusion accuracy, a new fusion method for dual-modality tomography (luminescence/fluorescence and micro-CT) based on natural light surface reconstruction (NLSR) and iterated closest point (ICP) was presented. It consisted of Octree structure, exact visual hull from marching cubes and ICP. Different from conventional limited projection methods, it is 360° free-space registration, and utilizes more luminescence/fluorescence distribution information from unlimited multi-orientation 2D optical images. A mouse mimicking phantom (one XPM-2 Phantom Light Source, XENOGEN Corporation) and an in-vivo BALB/C mouse with implanted one luminescent light source were used to evaluate the performance of the new fusion method. Compared with conventional fusion methods, the average error of preset markers was improved by 0.3 and 0.2 pixels from the new method, respectively. After running the same 3D internal light source reconstruction algorithm of the BALB/C mouse, the distance error between the actual and reconstructed internal source was decreased by 0.19 mm.
MIRAP, microcomputer reliability analysis program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jehee, J.N.T.
1989-01-01
A program for a microcomputer is outlined that can determine minimal cut sets from a specified fault tree logic. The speed and memory limitations of the microcomputers on which the program is implemented (Atari ST and IBM) are addressed by reducing the fault tree's size and by storing the cut set data on disk. Extensive well proven fault tree restructuring techniques, such as the identification of sibling events and of independent gate events, reduces the fault tree's size but does not alter its logic. New methods are used for the Boolean reduction of the fault tree logic. Special criteria formore » combining events in the 'AND' and 'OR' logic avoid the creation of many subsuming cut sets which all would cancel out due to existing cut sets. Figures and tables illustrates these methods. 4 refs., 5 tabs.« less
Applications of Microcomputers in Patient Care
Eden, Henry S.
1979-01-01
This paper serves as an introduction to two sessions on microcomputer applications in patient care. It describes several advantages offered by microcomputers in the design of medical devices--flexibility, reliability, smallness, and low power consumption. It concludes by discussing eight categories of microcomputer application.
Computed tomography-based tissue-engineered scaffolds in craniomaxillofacial surgery.
Smith, M H; Flanagan, C L; Kemppainen, J M; Sack, J A; Chung, H; Das, S; Hollister, S J; Feinberg, S E
2007-09-01
Tissue engineering provides an alternative modality allowing for decreased morbidity of donor site grafting and decreased rejection of less compatible alloplastic tissues. Using image-based design and computer software, a precisely sized and shaped scaffold for osseous tissue regeneration can be created via selective laser sintering. Polycaprolactone has been used to create a condylar ramus unit (CRU) scaffold for application in temporomandibular joint reconstruction in a Yucatan minipig animal model. Following sacrifice, micro-computed tomography and histology was used to demonstrate the efficacy of this particular scaffold design. A proof-of-concept surgery has demonstrated cartilaginous tissue regeneration along the articulating surface with exuberant osseous tissue formation. Bone volumes and tissue mineral density at both the 1 and 3 month time points demonstrated significant new bone growth interior and exterior to the scaffold. Computationally designed scaffolds can support masticatory function in a large animal model as well as both osseous and cartilage regeneration. Our group is continuing to evaluate multiple implant designs in both young and mature Yucatan minipig animals. 2007 John Wiley & Sons, Ltd.
Multi-scale analytical investigation of fly ash in concrete
NASA Astrophysics Data System (ADS)
Aboustait, Mohammed B.
Much research has been conducted to find an acceptable concrete ingredient that would act as cement replacement. One promising material is fly ash. Fly ash is a by-product from coal-fired power plants. Throughout this document work on the characterization of fly ash structure and composition will be explored. This effort was conducted through a mixture of cutting edge multi-scale analytical X-ray based techniques that use both bulk experimentation and nano/micro analytical techniques. Furtherly, this examination was coupled by performing Physical/Mechanical ASTM based testing on fly ash-enrolled-concrete to examine the effects of fly ash introduction. The most exotic of the cutting edge characterization techniques endorsed in this work uses the Nano-Computed Tomography and the Nano X-ray Fluorescence at Argonne National Laboratory to investigate single fly ash particles. Additional Work on individual fly ash particles was completed by laboratory-based Micro-Computed Tomography and Scanning Electron Microscopy. By combining the results of individual particles and bulk property tests, a compiled perspective is introduced, and accessed to try and make new insights into the reactivity of fly ash within concrete.
Microcomputer Applications in Agriculture.
ERIC Educational Resources Information Center
Hilgenberg, Gene; And Others
This curriculum guide is intended to assist persons teaching a course in microcomputer applications in agriculture. (These applications are designed to be used on Apple IIe or TRS-80 microcomputers.) Addressed in the individual units of instruction are the following topics: microcomputer operating procedures; procedures for evaluating and…
On Selecting a Microcomputer for 1800 Freshmen at Drexel.
ERIC Educational Resources Information Center
Smith, Allan L.; And Others
1984-01-01
Presents report to Vice President for Academic Affairs of Drexel University which formed the basis for negotiating an agreement with Apple Corporation to provide required microcomputers for incoming freshmen. Microcomputer Selection Committee constitution and charge, student ownership goals, requirements and specifications for the microcomputers,…
Refinery spreadsheet highlights microcomputer process applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tucker, M.A.
1984-01-23
Microcomputer applications in the process areas at Chevron U.S.A. refineries and at the Chevron Research Co. illustrate how the microcomputer has changed the way we do our jobs. This article will describe major uses of the microcomputer as a personal work tool in Chevron process areas. It will also describe how and why many of Chevron's microcomputer applications were developed and their characteristics. One of our earliest microcomputer applications, developed in late 1981, was an electronic spreadsheet program using a small desktop microcomputer. It was designed to help a refinery planner prepare monthly plans for a small portion of onemore » of our major refineries. This particular microcomputer had a tiny 4-in. screen, and the reports were several strips of print-out from the microcomputer's 3-in.-wide internal printer taped together. In spite of these archaic computing conditions, it was a successful application. It automated what had been very tedious and time-consuming calculations with a pencil, a calculator, and a great deal of erasing. It eliminated filling out large ''horseblanket'' reports. The electronic spreadsheet was also flexible; the planner could easily change the worksheet to match new operating constraints, new process conditions, and new feeds and products. Fortunately, within just a few months, this application graduated to a similar electronic spreadsheet program on a new, more powerful microcomputer. It had a bigger display screen and a letter-size printer. The same application is still in use today, although it has been greatly enhanced and altered to match extensive plant modifications. And there are plans to expand it again onto yet another, more powerful microcomputer.« less
The Power of the New Microcomputers: Challenge and Opportunity.
ERIC Educational Resources Information Center
Rumsey, Eric
1990-01-01
Describes current developments in microcomputer technology, including CD-ROM, the 80386 microprocessor, and the graphic user interface. It is argued that, as the information handling capacity of microcomputers increases, the microcomputer industry will increasingly market information to end users, and the library will be challenged to provide the…
Installing a Microcomputer Lab in a Medium-Sized Academic Library.
ERIC Educational Resources Information Center
Hallman, Clark N.; And Others
Designed to serve as a blueprint for other libraries developing plans for microcomputer facilities, this report describes the planning and implementation of a microcomputer laboratory at South Dakota State University's Hilton M. Briggs Library. The university's plan for installing microcomputer labs on campus and the initial planning process…
TLC for Growing Minds. Microcomputer Projects. Elementary Intermediate Microcomputer Projects.
ERIC Educational Resources Information Center
Buxton, Marilyn
Designed to improve students' thinking, learning, and creative skills while they learn to program a microcomputer in BASIC programing language, this book for intermediate learners at the elementary school level provides a variety of microcomputer activities designed to extend the concepts learned in accompanying instructional manuals (Volumes 3…
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, T.F.; Mok, G.C.; Carlson, R.W.
1996-12-01
CASKS is a microcomputer based computer system developed by LLNL to assist the Nuclear Regulatory Commission in performing confirmatory analyses for licensing review of radioactive-material storage cask designs. The analysis programs of the CASKS computer system consist of four modules--the impact analysis module, the thermal analysis module, the thermally-induced stress analysis module, and the pressure-induced stress analysis module. CASKS uses a series of menus to coordinate input programs, cask analysis programs, output programs, data archive programs and databases, so the user is able to run the system in an interactive environment. This paper outlines the theoretical background on the impactmore » analysis module and the yielding surface formulation. The close agreement between the CASKS analytical predictions and the results obtained form the two storage asks drop tests performed by SNL and by BNFL at Winfrith serves as the validation of the CASKS impact analysis module.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, T.F.; Mok, G.C.; Carlson, R.W.
1995-08-01
CASKS is a microcomputer based computer system developed by LLNL to assist the Nuclear Regulatory Commission in performing confirmatory analyses for licensing review of radioactive-material storage cask designs. The analysis programs of the CASKS computer system consist of four modules: the impact analysis module, the thermal analysis module, the thermally-induced stress analysis module, and the pressure-induced stress analysis module. CASKS uses a series of menus to coordinate input programs, cask analysis programs, output programs, data archive programs and databases, so the user is able to run the system in an interactive environment. This paper outlines the theoretical background on themore » impact analysis module and the yielding surface formulation. The close agreement between the CASKS analytical predictions and the results obtained form the two storage casks drop tests performed by SNL and by BNFL at Winfrith serves as the validation of the CASKS impact analysis module.« less
NLM microcomputer-based tutorials (for microcomputers). Software
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perkins, M.
1990-04-01
The package consists of TOXLEARN--a microcomputer-based training package for TOXLINE (Toxicology Information Online), CHEMLEARN-a microcomputer-based training package for CHEMLINE (Chemical Information Online), MEDTUTOR--a microcomputer-based training package for MEDLINE (Medical Information Online), and ELHILL LEARN--a microcomputer-based training package for the ELHILL search and retrieval software that supports the above-mentioned databases...Software Description: The programs were developed under PILOTplus using the NLM LEARN Programmer. They run on IBM-PC, XT, AT, PS/2, and fully compatible computers. The programs require 512K RAM memory, one disk drive, and DOS 2.0 or higher. The software supports most monochrome, color graphics, enhanced color graphics, or visual graphics displays.
Non-Destructive Characterization of UO2+x Nuclear Fuels
Pokharel, Reeju; Brown, Donald W.; Clausen, Bjørn; ...
2017-10-27
This article describes the effect of fabrication conditions on as-sintered microstructures of various stoichiometric ratios of uranium dioxide, UO 2+x, with the aim of enhancing the understanding of fabrication process and developing and validating a predictive microstructurebased model for fuel performance. We demonstrate the ability of novel, non-destructive methods such as near-field high-energy X-ray diffraction microscopy (nf-HEDM) and micro-computed tomography (μ-CT) to probe bulk samples of high-Z materials by non-destructively characterizing three samples: UO 2.00, UO 2.11, and UO 2.16, which were sintered at 1450°C for 4 hours. The measured 3D microstructures revealed that grain size and porosity were influencedmore » by deviation from stoichiometry.« less
Micromechanics of Sea Urchin spines.
Tsafnat, Naomi; Fitz Gerald, John D; Le, Hai N; Stachurski, Zbigniew H
2012-01-01
The endoskeletal structure of the Sea Urchin, Centrostephanus rodgersii, has numerous long spines whose known functions include locomotion, sensing, and protection against predators. These spines have a remarkable internal microstructure and are made of single-crystal calcite. A finite-element model of the spine's unique porous structure, based on micro-computed tomography (microCT) and incorporating anisotropic material properties, was developed to study its response to mechanical loading. Simulations show that high stress concentrations occur at certain points in the spine's architecture; brittle cracking would likely initiate in these regions. These analyses demonstrate that the organization of single-crystal calcite in the unique, intricate morphology of the sea urchin spine results in a strong, stiff and lightweight structure that enhances its strength despite the brittleness of its constituent material.
Development of High-Speed Fluorescent X-Ray Micro-Computed Tomography
NASA Astrophysics Data System (ADS)
Takeda, T.; Tsuchiya, Y.; Kuroe, T.; Zeniya, T.; Wu, J.; Lwin, Thet-Thet; Yashiro, T.; Yuasa, T.; Hyodo, K.; Matsumura, K.; Dilmanian, F. A.; Itai, Y.; Akatsuka, T.
2004-05-01
A high-speed fluorescent x-ray CT (FXCT) system using monochromatic synchrotron x rays was developed to detect very low concentration of medium-Z elements for biomedical use. The system is equipped two types of high purity germanium detectors, and fast electronics and software. Preliminary images of a 10mm diameter plastic phantom containing channels field with iodine solutions of different concentrations showed a minimum detection level of 0.002 mg I/ml at an in-plane spatial resolution of 100μm. Furthermore, the acquisition time was reduced about 1/2 comparing to previous system. The results indicate that FXCT is a highly sensitive imaging modality capable of detecting very low concentration of iodine, and that the method has potential in biomedical applications.
Kovacevic, David; Fox, Alice J; Bedi, Asheesh; Ying, Liang; Deng, Xiang-Hua; Warren, Russell F; Rodeo, Scott A
2011-04-01
Rotator cuff tendon heals by formation of an interposed zone of fibrovascular scar tissue. Recent studies demonstrate that transforming growth factor-beta 3 (TGF-β(3)) is associated with tissue regeneration and "scarless" healing, in contrast to scar-mediated healing that occurs with TGF-β(1). Delivery of TGF-β(3) in an injectable calcium-phosphate matrix to the healing tendon-bone interface after rotator cuff repair will result in increased attachment strength secondary to improved bone formation and collagen organization and reduced scar formation of the healing enthesis. Controlled laboratory study. Ninety-six male Sprague-Dawley rats underwent unilateral detachment of the supraspinatus tendon followed by acute repair using transosseous suture fixation. Animals were allocated into 1 of 3 groups: (1) repair alone (controls, n = 32), (2) repair augmented by application of an osteoconductive calcium-phosphate (Ca-P) matrix only (n = 32), or (3) repair augmented with Ca-P matrix + TGF-β(3) (2.75 µg) at the tendon-bone interface (n = 32). Animals were euthanized at either 2 weeks or 4 weeks postoperatively. Biomechanical testing of the supraspinatus tendon-bone complex was performed at 2 and 4 weeks (n = 8 per group). Microcomputed tomography was utilized to quantitate bone microstructure at the repair site. The healing tendon-bone interface was evaluated with histomorphometry and immunohistochemical localization of collagen types I (COLI) and III (COLIII). Statistical analysis was performed using 2-way analysis of variance with significance set at P < .05. There was significantly greater load to failure of the Ca-P matrix + TGF-β(3) group compared with matrix alone or untreated controls at 4 weeks postoperatively (P = .04). At 2 weeks, microcomputed tomography revealed a larger volume of newly formed bone present at the healing enthesis in both experimental groups compared with the control group. By 4 weeks, this newly formed, woven bone had matured into calcified, lamellar bone. Histomorphometric analysis demonstrated significantly greater fibrocartilage and increased collagen organization at the healing tendon-bone insertion site in both experimental groups compared with the control group at 2 weeks (P = .04). Over time, TGF-β(3) delivery led to greater COLI expression compared with COLIII at the healing enthesis, indicating a more favorable COLI to COLIII ratio with administration of TGF-β(3). Augmentation with an osteoconductive Ca-P matrix at the tendon-bone repair site is associated with new bone formation, increased fibrocartilage, and improved collagen organization at the healing tendon-bone interface in the early postoperative period after rotator cuff repair. The addition of TGF-β(3) significantly improved strength of the repair at 4 weeks postoperatively and resulted in a more favorable COLI/COLIII ratio. The delivery of TGF-β(3) with an injectable Ca-P matrix at the supraspinatus tendon footprint has promise to improve healing after soft tissue repair.
Exploiting parallel computing with limited program changes using a network of microcomputers
NASA Technical Reports Server (NTRS)
Rogers, J. L., Jr.; Sobieszczanski-Sobieski, J.
1985-01-01
Network computing and multiprocessor computers are two discernible trends in parallel processing. The computational behavior of an iterative distributed process in which some subtasks are completed later than others because of an imbalance in computational requirements is of significant interest. The effects of asynchronus processing was studied. A small existing program was converted to perform finite element analysis by distributing substructure analysis over a network of four Apple IIe microcomputers connected to a shared disk, simulating a parallel computer. The substructure analysis uses an iterative, fully stressed, structural resizing procedure. A framework of beams divided into three substructures is used as the finite element model. The effects of asynchronous processing on the convergence of the design variables are determined by not resizing particular substructures on various iterations.
Exceptional Children and Microcomputers, A Survey of Public School Applications.
ERIC Educational Resources Information Center
Crowner, T. Timothy
Telephone interviews on the use of microcomputers in special education were administered to personnel in 25 districts (drawn from a random sample of the largest school districts in the United States) on the following topics: coordination of microcomputers; numbers of microcomputers owned and used; pragmatic uses; funding; brands used; selection,…
Fabricating a Microcomputer on a Single Silicon Wafer
NASA Technical Reports Server (NTRS)
Evanchuk, V. L.
1983-01-01
Concept for "microcomputer on a slice" reduces microcomputer costs by eliminating scribing, wiring, and packaging of individual circuit chips. Low-cost microcomputer on silicon slice contains redundant components. All components-central processing unit, input/output circuitry, read-only memory, and random-access memory (CPU, I/O, ROM, and RAM) on placed on single silicon wafer.
TLC for Growing Minds. Microcomputer Projects. Adult Intermediate Microcomputer Projects.
ERIC Educational Resources Information Center
Taitt, Henry A.
Designed to improve students' thinking, learning, and creative skills while they learn to program a microcomputer in BASIC programing language, this book for intermediate learners at the high school/adult level provides a variety of microcomputer activities designed to extend the concepts taught in the accompanying instructional manuals (Volumes 3…
Microcomputers in American Public Schools: A National Survey.
ERIC Educational Resources Information Center
Ingersoll, Gary M.; And Others
1983-01-01
In the 1981-82 school year, microcomputers were located in one-third of United States schools. The dominant share for school-based microcomputers was held by Apple Computer followed by Tandy-Radio Shack and Commodore, but this was regionally related. The majority of teachers polled possess positive attitudes toward classroom use of microcomputers.…
A Low Cost Microcomputer Laboratory for Investigating Computer Architecture.
ERIC Educational Resources Information Center
Mitchell, Eugene E., Ed.
1980-01-01
Described is a microcomputer laboratory at the United States Military Academy at West Point, New York, which provides easy access to non-volatile memory and a single input/output file system for 16 microcomputer laboratory positions. A microcomputer network that has a centralized data base is implemented using the concepts of computer network…
Towards true 3D textural analysis; using your crystal mush wisely.
NASA Astrophysics Data System (ADS)
Jerram, D. A.; Morgan, D. J.; Pankhurst, M. J.
2014-12-01
The crystal cargo that is found in volcanic and plutonic rocks contains a wealth of information about magmatic mush processes, crystallisation history, crystal entrainment and recycling. Phenocryst populations predominantly record episodes of growth/nucleation and bulk geochemical changes within an evolving crystal-melt body. Ante- and xeno-crysts provide useful clues to the nature of mush interaction with wall rock and with principal magma(s). Furthermore, crystal evolutions (core to rim) record pathways through pressure, temperature and compositional space. These can often illustrate complex recycling within systems, describing the plumbing architecture. Understanding this architecture underpins our knowledge of how igneous systems can interact with the crust, grow, freeze, re-mobilise and prime for eruption. Initially, 2D studies produced corrected 3D crystal size distributions to help provide information about nucleation and residence times. It immediately became clear that crystal shape is an important factor in determining the confidence placed upon 3D reconstructions of 2D data. Additionally studies utilised serial sections of medium- to coarse-grain-size populations which allowed 3D reconstruction using modelling software to be improved, since size and shape etc. can be directly constrained. Finally the advent of textural studies using X-ray tomography has revolutionised the way in which we can inspect the crystal cargo in mushy systems, allowing us to image in great detail crystal packing arrangements, 3D CSDs, shapes and orientations etc. The latest most innovative studies use X-ray micro-computed tomography to rapidly characterise chemical populations within the crystal cargo, adding a further dimension to this approach, and implies the ability to untangle magmatic chemical components to better understand their individual and combined evolution. In this contribution key examples of the different types of textural analysis techniques in 2D and 3D, including texture movie animations, are used from both plutonic and volcanic systems to highlight the roll of this approach towards a goal of true 3D textural analysis.
Saha, Punam K; Xu, Yan; Duan, Hong; Heiner, Anneliese; Liang, Guoyuan
2010-11-01
Trabecular bone (TB) is a complex quasi-random network of interconnected plates and rods. TB constantly remodels to adapt to the stresses to which it is subjected (Wolff's Law). In osteoporosis, this dynamic equilibrium between bone formation and resorption is perturbed, leading to bone loss and structural deterioration. Both bone loss and structural deterioration increase fracture risk. Bone's mechanical behavior can only be partially explained by variations in bone mineral density, which led to the notion of bone structural quality. Previously, we developed digital topological analysis (DTA) which classifies plates, rods, profiles, edges, and junctions in a TB skeletal representation. Although the method has become quite popular, a major limitation of DTA is that it provides only hard classifications of different topological entities, failing to distinguish between narrow and wide plates. Here, we present a new method called volumetric topological analysis (VTA) for regional quantification of TB topology. At each TB location, the method uniquely classifies its topology on the continuum between perfect plates and perfect rods, facilitating early detections of TB alterations from plates to rods according to the known etiology of osteoporotic bone loss. Several new ideas, including manifold distance transform, manifold scale, and feature propagation have been introduced here and combined with existing DTA and distance transform methods, leading to the new VTA technology. This method has been applied to multidetector computed tomography (CT) and micro-computed tomography ( μCT) images of four cadaveric distal tibia and five distal radius specimens. Both intra- and inter-modality reproducibility of the method has been examined using repeat CT and μCT scans of distal tibia specimens. Also, the method's ability to predict experimental biomechanical properties of TB via CT imaging under in vivo conditions has been quantitatively examined and the results found are very encouraging.
Microcomputer package for statistical analysis of microbial populations.
Lacroix, J M; Lavoie, M C
1987-11-01
We have developed a Pascal system to compare microbial populations from different ecological sites using microcomputers. The values calculated are: the coverage value and its standard error, the minimum similarity and the geometric similarity between two biological samples, and the Lambda test consisting of calculating the ratio of the mean similarity between two subsets by the mean similarity within subsets. This system is written for Apple II, IBM or compatible computers, but it can work for any computer which can use CP/M, if the programs are recompiled for such a system.
1983-06-01
the study of linear control theory may be adapted to run on an inex- pensive home/microcomputer. To demonstrate this, five programs were chosen from...COMMON LOG OF FREQUENCY ORDINATE -> PHASE (DEGREES) TIC MARKS SHOW MULTIPLES OF 98 DEGREES MINIMUM FREQUENCY SHOI ON ABSCISSA = .1 RADIANS/SEC...stability. The phase margin is 64.5 degrees which is also lower than the previous case but only by one tenth of a degree. d. w’-Plane with a Period of .1
Maret, Delphine; Peters, Ove A; Galibourg, Antoine; Dumoncel, Jean; Esclassan, Rémi; Kahn, Jean-Luc; Sixou, Michel; Telmon, Norbert
2014-09-01
Cone-beam computed tomography (CBCT) data are, in principle, metrically exact. However, clinicians need to consider the precision of measurements of dental morphology as well as other hard tissue structures. CBCT spatial resolution, and thus image reconstruction quality, is restricted by the acquisition voxel size. The aim of this study was to assess geometric discrepancies among 3-dimensional CBCT reconstructions relative to the micro-CT reference. A total of 37 permanent teeth from 9 mandibles were scanned with CBCT 9500 and 9000 3D and micro-CT. After semiautomatic segmentation, reconstructions were obtained from CBCT acquisitions (voxel sizes 76, 200, and 300 μm) and from micro-CT (voxel size 41 μm). All reconstructions were positioned in the same plane by image registration. The topography of the geometric discrepancies was displayed by using a color map allowing the maximum differences to be located. The maximum differences were mainly found at the cervical margins and on the cusp tips or incisal edges. Geometric reconstruction discrepancies were significant at 300-μm resolution (P = .01, Wilcoxon test). To study hard tissue morphology, CBCT acquisitions require voxel sizes smaller than 300 μm. This experimental study will have to be complemented by studies in vivo that consider the conditions of clinical practice. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Masticatory biomechanics in the rabbit: a multi-body dynamics analysis.
Watson, Peter J; Gröning, Flora; Curtis, Neil; Fitton, Laura C; Herrel, Anthony; McCormack, Steven W; Fagan, Michael J
2014-10-06
Multi-body dynamics is a powerful engineering tool which is becoming increasingly popular for the simulation and analysis of skull biomechanics. This paper presents the first application of multi-body dynamics to analyse the biomechanics of the rabbit skull. A model has been constructed through the combination of manual dissection and three-dimensional imaging techniques (magnetic resonance imaging and micro-computed tomography). Individual muscles are represented with multiple layers, thus more accurately modelling muscle fibres with complex lines of action. Model validity was sought through comparing experimentally measured maximum incisor bite forces with those predicted by the model. Simulations of molar biting highlighted the ability of the masticatory system to alter recruitment of two muscle groups, in order to generate shearing or crushing movements. Molar shearing is capable of processing a food bolus in all three orthogonal directions, whereas molar crushing and incisor biting are predominately directed vertically. Simulations also show that the masticatory system is adapted to process foods through several cycles with low muscle activations, presumably in order to prevent rapidly fatiguing fast fibres during repeated chewing cycles. Our study demonstrates the usefulness of a validated multi-body dynamics model for investigating feeding biomechanics in the rabbit, and shows the potential for complementing and eventually reducing in vivo experiments.
Masticatory biomechanics in the rabbit: a multi-body dynamics analysis
Watson, Peter J.; Gröning, Flora; Curtis, Neil; Fitton, Laura C.; Herrel, Anthony; McCormack, Steven W.; Fagan, Michael J.
2014-01-01
Multi-body dynamics is a powerful engineering tool which is becoming increasingly popular for the simulation and analysis of skull biomechanics. This paper presents the first application of multi-body dynamics to analyse the biomechanics of the rabbit skull. A model has been constructed through the combination of manual dissection and three-dimensional imaging techniques (magnetic resonance imaging and micro-computed tomography). Individual muscles are represented with multiple layers, thus more accurately modelling muscle fibres with complex lines of action. Model validity was sought through comparing experimentally measured maximum incisor bite forces with those predicted by the model. Simulations of molar biting highlighted the ability of the masticatory system to alter recruitment of two muscle groups, in order to generate shearing or crushing movements. Molar shearing is capable of processing a food bolus in all three orthogonal directions, whereas molar crushing and incisor biting are predominately directed vertically. Simulations also show that the masticatory system is adapted to process foods through several cycles with low muscle activations, presumably in order to prevent rapidly fatiguing fast fibres during repeated chewing cycles. Our study demonstrates the usefulness of a validated multi-body dynamics model for investigating feeding biomechanics in the rabbit, and shows the potential for complementing and eventually reducing in vivo experiments. PMID:25121650
Zinelis, Spiros; Al Jabbari, Youssef S
2018-05-01
This study was conducted to evaluate the failure mechanism of clinically failed Hedstrom (H)-files. Discarded H-files (n=160) from #8 to #40 ISO sizes were collected from different dental clinics. Retrieved files were classified according to their macroscopic appearance and they were investigated under scanning electron microscopy (SEM) and X-ray micro-computed tomography (mXCT). Then the files were embedded in resin along their longitudinal axis and after metallographic grinding and polishing, studied under an incident light microscope. The macroscopic evaluation showed that small ISO sizes (#08-#15) failed by extensive plastic deformation, while larger sizes (≥#20) tended to fracture. Light microscopy and mXCT results coincided showing that unused and plastically deformed files were free of internal defects, while fractured files demonstrate the presence of intense cracking in the flute region. SEM analysis revealed the presence of striations attributed to the fatigue mechanism. Secondary cracks were also identified by optical microscopy and their distribution was correlated to fatigue under bending loading. Experimental results demonstrated that while overloading of cutting instruments is the predominating failure mechanism of small file sizes (#08-#15), fatigue should be considered the fracture mechanism for larger sizes (≥#20).
Designer bFGF-incorporated d-form self-assembly peptide nanofiber scaffolds to promote bone repair.
He, Bin; Ou, Yunsheng; Chen, Shuo; Zhao, Weikang; Zhou, Ao; Zhao, Jinqiu; Li, Hong; Jiang, Dianming; Zhu, Yong
2017-05-01
d-Form and l-form peptide nanofiber scaffolds can spontaneously form stable β-sheet secondary structures and nanofiber hydrogel scaffolds, and hold some promise in hemostasis and wound healing. We report here on the synthetic self-assembling peptide d-RADA16 and l-RADA16 are both found to produce stable β-sheet secondary structure and nanofiber hydrogel scaffolds based on circular dichroism (CD) spectroscopy, transmission electron microscopy (TEM) and rheology analysis etc. d-RADA16 hydrogel and l-RADA16 hydrogel can enhance obvious bone repair in femoral condyle defects of the Sprague-Dawley (SD) rat model compared to PBS treatment. Based on micro-computed tomography (CT), it was revealed that d-RADA16 hydrogel and l-RADA16 hydrogel were capable to obtain the extensive bone healing. Histological evaluation also found that these two hydrogels facilitate the presence of more mature bone tissue within the femoral condyle defects. Additionally, d-RADA16 hydrogel showed some potential in storing and releasing basic-fibroblast growth factor (bFGF) which was able to further promote bone regeneration based on micro-CT analysis. These results indicate that d-form peptide nanofiber hydrogel have some special capacity for bone repair. Copyright © 2016 Elsevier B.V. All rights reserved.
Xia, Yan; Zhou, Panyu; Wang, Fei; Qiu, Chao; Wang, Panfeng; Zhang, Yuntong; Zhao, Liming; Xu, Shuogui
2016-01-01
In this study, bioactive scaffold of nano magnesium phosphate (nMP)/wheat protein (WP) composite (MWC) was fabricated. The results revealed that the MWC scaffolds had interconnected not only macropores (sized 400-600 μm) but also micropores (sized 10-20 μm) on the walls of macropores. The MWC scaffolds containing 40 w% nMP had an appropriate degradability in phosphate-buffered saline and produced a weak alkaline microenvironment. In cell culture experiments, the results revealed that the MWC scaffolds significantly promoted the MC3T3-E1 cell proliferation, differentiation, and growth into the scaffolds. The results of synchrotron radiation microcomputed tomography and analysis of the histological sections of the in vivo implantation revealed that the MWC scaffolds evidently improved the new bone formation and bone defects repair as compared with WP scaffolds. Moreover, it was found that newly formed bone tissue continued to increase with the gradual reduction of materials residual in the MWC scaffolds. Furthermore, the immunohistochemical analysis further offered the evidence of the stimulatory effects of MWC scaffolds on osteogenic-related cell differentiation and new bone regeneration. The results indicated that MWC scaffolds with good biocompability and degradability could promote osteogenesis in vivo, which would have potential for bone tissue repair.
Finite Element Analysis (FEA) in Design and Production.
ERIC Educational Resources Information Center
Waggoner, Todd C.; And Others
1995-01-01
Finite element analysis (FEA) enables industrial designers to analyze complex components by dividing them into smaller elements, then assessing stress and strain characteristics. Traditionally mainframe based, FEA is being increasingly used in microcomputers. (SK)
Satellite Doppler data processing using a microcomputer
NASA Technical Reports Server (NTRS)
Schmid, P. E.; Lynn, J. J.
1977-01-01
A microcomputer which was developed to compute ground radio beacon position locations using satellite measurements of Doppler frequency shift is described. Both the computational algorithms and the microcomputer hardware incorporating these algorithms were discussed. Results are presented where the microcomputer in conjunction with the NIMBUS-6 random access measurement system provides real time calculation of beacon latitude and longitude.
User's guide to the LLL BASIC interpreter. [For 8080-based MCS-80 microcomputer system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Allison, T.; Eckard, R.; Barber, J.
1977-06-09
Scientists are finding increased applications for microcomputers as process controllers in their experiments. However, while microcomputers are small and inexpensive, they are difficult to program in machine or assembly language. A high-level language is needed to enable scientists to develop their own microcomputer programs for their experiments on location. Recognizing this need, LLL contracted to have such a language developed. This report describes the result--the LLL BASIC interpreter, which operates with LLL's 8080-based MCS-80 microcomputer system. 4 tables.
Raddatz, Maik
2017-01-01
We report a new, small-sized atoposaurid crocodyliform from the Upper Jurassic of Langenberg, Northeastern Germany. Atoposaurids are small-sized Mesozoic crocodyliforms of mainly European distribution, which are considered to be phylogenetically close to the origin of Eusuchia. Knoetschkesuchus langenbergensis gen. nov. sp. nov. is represented by two well-preserved skulls and additional cranial and postcranial remains representing different ontogenetic stages. 3D reconstructions of a juvenile skull based on micro-computed tomography allow the most detailed description of cranial remains of any atoposaurid hitherto presented. Our new analysis contradicts previous preliminary assignment of the Langenberg atoposaurids to Theriosuchus. Knoetschkesuchus gen. nov. is characterized in particular by the presence of two dental morphotypes in the maxilla and dentary, slit-like secondary choanae within a narrow groove on the surface of the pterygoid, absence of lacrimonasal contact, presence of an antorbital foramen and an external mandibular fenestra, and proportional characters of the interorbital and intertemporal region. A similar combination of characters allows attribution of Theriosuchus guimarotae to Knoetschkesuchus, forming the new combination Knoetschkesuchus guimarotae. Our analysis provides an osteological basis for the separation of Theriosuchus and Knoetschkesuchus and helps further delineate generic differences in other closely related crocodylomorphs. Our phylogenetic analysis corroborates inclusion of Knoetschkesuchus into Atoposauridae and supports a position of Atoposauridae within Eusuchia. PMID:28199316
Zacchetti, Giovanna; Rizzoli, René
2014-01-01
Rapid bone defect filling with normal bone is a challenge in orthopaedics and dentistry. Strontium ranelate (SrRan) has been shown to in vitro decrease bone resorption and increase bone formation, and represents a potential agent with the capacity to accelerate bone defect filling. In this study, bone tibial defects of 2.5 mm in diameter were created in 6-month-old female rats orally fed SrRan (625 mg/kg/d; 5/7 days) or vehicle for 4, 8, or 12 weeks (10 rats per group per time point) from the time of surgery. Tibias were removed. Micro-architecture was determined by micro-computed tomography (µCT) and material level properties by nanoindentation analysis. µCT analysis showed that SrRan administration significantly improved microarchitecture of trabecular bone growing into the defect after 8 and 12 weeks of treatment compared to vehicle. SrRan treatment also accelerated the growth of cortical bone over the defect, but with different kinetics compared to trabecular bone, as the effects were already significant after 4 weeks. Nanoindentation analysis demonstrated that SrRan treatment significantly increased material level properties of both trabecular bone and cortical bone filling the defect compared to vehicle. SrRan accelerates the filling of bone defect by improving cortical and trabecular bone microarchitecture both quantitatively and qualitatively. PMID:25243150
Biodegradable nasal stents (MgF2 -coated Mg-2 wt %Nd alloy)-A long-term in vivo study.
Durisin, Martin; Reifenrath, Janin; Weber, Constantin M; Eifler, Rainer; Maier, Hans J; Lenarz, Thomas; Seitz, Jan-Marten
2017-02-01
Despite innovative surgical techniques and use of current frontal sinus stents from different materials, the problem of treatment failure with consecutive reoperation remains present. The aim of our study is to investigate biocompatibility, degradation kinetics, and functionality of a newly developed fluoride-coated magnesium-based nasal stent. A minipig anatomy of frontal sinus adapted design and an external surgical approach were developed and established. The functionality of the stents was evaluated endoscopically. The stent-tissue blocks were analysed after 90 and 180 days using microcomputed tomography (µ-CT), histology, scanning electron microscopy (SEM), and energy-dispersive X-ray spectroscopy (EDS). Functional evaluation revealed an unobstructed stent lumen in all cases. Histological analysis showed moderate mucosal hyperplasia with a mild, nonspecific inflammatory response, and nonosteoconductive effect. Rejection reactions or necrosis did not occur. The volumetric analysis of the stents showed 51% volume loss after 180 days. The EDS analysis did not detect any neodymium (Nd) in the mucosa or bone. The Mg-2 wt % Nd stents are a promising option when treating the narrow passages following paranasal sinus surgery. In particular, its good biocompatibility and good functionality facilitate the re-epithelization of these constricted passages. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 350-365, 2017. © 2015 Wiley Periodicals, Inc.
Harms, Christoph; Helms, Kai; Taschner, Tibor; Stratos, Ioannis; Ignatius, Anita; Gerber, Thomas; Lenz, Solvig; Rammelt, Stefan; Vollmar, Brigitte; Mittlmeier, Thomas
2012-01-01
The synthetic material Nanobone(®) (hydroxyapatite nanocrystallines embedded in a porous silica gel matrix) was examined in vivo using a standardized bone defect model in the ovine tibial metaphysis. A standardized 6 × 12 × 24-mm bone defect was created below the articular surface of the medial tibia condyles on both hind legs of 18 adult sheep. The defect on the right side was filled with Nanobone(®), while the defect on the contralateral side was left empty. The tibial heads of six sheep were analyzed after 6, 12, and 26 weeks each. The histological and radiological analysis of the defect on the control side did not reveal any bone formation after the total of 26 weeks. In contrast, the microcomputed tomography analysis of the defect filled with Nanobone(®) showed a 55%, 72%, and 74% volume fraction of structures with bone density after 6, 12, and 26 weeks, respectively. Quantitative histomorphological analysis after 6, and 12 weeks revealed an osteoneogenesis of 22%, and 36%, respectively. Hematoxylin and eosin sections demonstrated multinucleated giant cells on the surface of the biomaterial and resorption lacunae, indicating osteoclastic resorptive activity. Nanobone(®) appears to be a highly potent bone substitute material with osteoconductive properties in a loaded large animal defect model, supporting the potential use of Nanobone(®) also in humans.
Harms, Christoph; Helms, Kai; Taschner, Tibor; Stratos, Ioannis; Ignatius, Anita; Gerber, Thomas; Lenz, Solvig; Rammelt, Stefan; Vollmar, Brigitte; Mittlmeier, Thomas
2012-01-01
The synthetic material Nanobone® (hydroxyapatite nanocrystallines embedded in a porous silica gel matrix) was examined in vivo using a standardized bone defect model in the ovine tibial metaphysis. A standardized 6 × 12 × 24-mm bone defect was created below the articular surface of the medial tibia condyles on both hind legs of 18 adult sheep. The defect on the right side was filled with Nanobone®, while the defect on the contralateral side was left empty. The tibial heads of six sheep were analyzed after 6, 12, and 26 weeks each. The histological and radiological analysis of the defect on the control side did not reveal any bone formation after the total of 26 weeks. In contrast, the microcomputed tomography analysis of the defect filled with Nanobone® showed a 55%, 72%, and 74% volume fraction of structures with bone density after 6, 12, and 26 weeks, respectively. Quantitative histomorphological analysis after 6, and 12 weeks revealed an osteoneogenesis of 22%, and 36%, respectively. Hematoxylin and eosin sections demonstrated multinucleated giant cells on the surface of the biomaterial and resorption lacunae, indicating osteoclastic resorptive activity. Nanobone® appears to be a highly potent bone substitute material with osteoconductive properties in a loaded large animal defect model, supporting the potential use of Nanobone® also in humans. PMID:22745551
Gropp, Kathryn E; Carlson, Cathy S; Evans, Mark G; Bagi, Cedo M; Reagan, William J; Hurst, Susan I; Shelton, David L; Zorbas, Mark A
2018-01-01
Tanezumab, an anti-nerve growth factor (NGF) antibody, is in development for management of chronic pain. During clinical trials of anti-NGF antibodies, some patients reported unexpected adverse events requiring total joint replacements, resulting in a partial clinical hold on all NGF inhibitors. Three nonclinical toxicology studies were conducted to evaluate the effects of tanezumab or the murine precursor muMab911 on selected bone and joint endpoints and biomarkers in cynomolgus monkeys, Sprague-Dawley rats, and C57BL/6 mice. Joint and bone endpoints included histology, immunohistochemistry, microcomputed tomography (mCT) imaging, and serum biomarkers of bone physiology. Responses of bone endpoints to tanezumab were evaluated in monkeys at 4 to 30 mg/kg/week for 26 weeks and in rats at 0.2 to 10 mg/kg twice weekly for 28 days. The effects of muMab911 at 10 mg/kg/week for 12 weeks on selected bone endpoints were determined in mice. Tanezumab and muMab911 had no adverse effects on any bone or joint parameter. There were no test article-related effects on bone or joint histology, immunohistochemistry, or structure. Reversible, higher osteocalcin concentrations occurred only in the rat study. No deleterious effects were observed in joints or bones in monkeys, rats, or mice administered high doses of tanezumab or muMab911.
Knaup, Thomas Johannes; Dirk, Cornelius; Reimann, Susanne; Keilig, Ludger; Eschbach, Meike; Korbmacher-Steiner, Heike; Bourauel, Christoph
2018-01-01
The aim of this study was to analyze the time-dependent in-vitro behavior of the periodontal ligament (PDL) by determining the material parameters using specimens of porcine jawbone. Time-dependent material parameters to be determined were expected to complement the results from earlier biomechanical studies. Five mandibular deciduous porcine premolars were analyzed in a combined experimental-numeric study. After selecting suitable specimens (excluding root resorption) and preparing the measurement system, the specimens were deflected by a distance of 0.2 mm at loading times of 0.2, 0.5, 1, 2, 5, 10, and 60 seconds. The deflection of the teeth was determined via a laser optical system, and the resulting forces and torques were measured. To create the finite element models, a microcomputed tomography scanner was used to create 3-dimensional x-ray images of the samples. The individual structures (tooth, PDL, bone) of the jaw segments were reconstructed using a self-developed reconstruction program. A comparison between experiment and simulation was conducted using the results from finite element simulations. Via iterative parameter adjustments, the material parameters (Young's modulus and Poisson's ratio) of the PDL were assessed at different loading velocities. The clinically observed effect of a distinct increase in force during very short periods of loading was confirmed. Thus, a force of 2.6 N (±1.5 N) was measured at the shortest stress duration of 0.2 seconds, and a force of 1.0 N (±0.5 N) was measured at the longest stress duration of 60 seconds. The numeric determination of the material parameters showed bilinear behavior with a median value of the first Young's modulus between 0.06 MPa (2 seconds) and 0.04 MPa (60 seconds), and the second Young's modulus between 0.30 MPa (10 seconds) and 0.20 MPa (60 seconds). The ultimate strain marking the transition from the first to the second Young's modulus remained almost unchanged with a median value of 6.0% for all loading times. A combined experimental-numeric analysis is suitable for determining the material properties of the PDL. Microcomputed tomography allows high-precision recordings with only minimum effort. This study confirms the assumption of time dependency and nonlinearity of previous studies. Copyright © 2017 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.
Quantification of the proliferation of arbuscular mycorrhizal fungi in soil
NASA Astrophysics Data System (ADS)
Zhang, Ning; Lilje, Osu; McGee, Peter
2013-04-01
Good soil structure is important for sustaining agricultural production and preserving functions of the soil ecosystem. Soil aggregation is a critically important component of soil structure. Stable aggregates enable water infiltration, gas exchange for biological activities of plant roots and microorganisms, living space and surfaces for soil microbes, and contribute to stabilization of organic matter and storage of organic carbon (OC) in soil. Soil aggregation involves fine roots, organic matter and hyphae of arbuscular mycorrhizal (AM) fungi. Hyphal proliferation is essential for soil aggregation and sequestration of OC in soil. We do not yet have a mechanism to directly quantify the density of hyphae in soil. Organic materials and available phosphorus are two of the major factors that influence fungi in soil. Organic materials are a source of energy for saprotrophic microbes. Fungal hyphae increase in the presence of organic matter. Phosphorus is an important element usually found in ecosystems. The low availability of phosphorus limits the biological activity of microbes. AM fungi benefit plants by delivering phosphorus to the root system. However, the density and the length of hyphae of AM fungi do not appear to be influenced by available phosphorus. A number of indirect methods have been used to visualize distribution of fungi in soil. Reliable analyses of soil are limited because of soil characteristics. Soils are fragile, and fragility limits opportunity for non-destructive analysis. The soil ecosystem is complex. Soil particles are dense and the density obscures the visualization of fungal hyphae. Fungal hyphae are relatively fine and information at the small scale (<250µm) is key to understanding how fungi respond to environmental stimuli. This experiment tested whether organic carbon (starch), phosphorus (K2HPO4) and their mixture influences proliferation of hyphae of AM fungi. Hyphae were quantified in an artificial soil matrix using micro-computer aided tomography. Micro-computer aided tomography provides three dimensional images of hyphal ramification through electron lucent materials and enables the visualization and quantification of hyphae. Starch and the mixture of starch plus K2HPO4, stimulated hyphal proliferation, while K2HPO4 alone did not change the density of hyphae. The images also indicate that fungal hyphae attached to the surfaces of the particles rather than grow through the spaces between them. The capacity to quantify hyphae in three-dimensional space allows a wide range of questions to now be addressed. Apart from studying mechanisms of carbon turnover, more complex processes may now be considered. Soil is commonly thought of as a black box. That black box is now a shade of grey.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chappard, Christine; Basillais, Armelle; Benhamou, Laurent
Microcomputed tomography ({mu}CT) produces three-dimensional (3D) images of trabecular bone. We compared conventional {mu}CT (C{mu}CT) with a polychromatic x-ray cone beam to synchrotron radiation (SR) {mu}CT with a monochromatic parallel beam for assessing trabecular bone microarchitecture of 14 subchondral femoral head specimens from patients with osteoarthritis (n=10) or osteoporosis (n=4). SR{mu}CT images with a voxel size of 10.13 {mu}m were reconstructed from 900 2D radiographic projections (angular step, 0.2 deg. ). C{mu}CT images with a voxel size of 10.77 {mu}m were reconstructed from 205, 413, and 825 projections obtained using angular steps of 0.9 deg., 0.45 deg., and 0.23 deg.,more » respectively. A single threshold was used to binarize the images. We computed bone volume/tissue volume (BV/TV), bone surface/bone volume (BS/BV), trabecular number (Tb.N), trabecular thickness (Tb.Th and Tb.Th*), trabecular spacing (Tb.Sp), degree of anisotropy (DA), and Euler density. With the 0.9 deg. angular step, all C{mu}CT values were significantly different from SR{mu}CT values. With the 0.23 deg. and 0.45 deg. rotation steps, BV/TV, Tb.Th, and BS/BV by C{mu}CT differed significantly from the values by SR{mu}CT. The error due to slice matching (visual site matching {+-}10 slices) was within 1% for most parameters. Compared to SR{mu}CT, BV/TV, Tb.Sp, and Tb.Th by C{mu}CT were underestimated, whereas Tb.N and Tb.Th* were overestimated. A Bland and Altman plot showed no bias for Tb.N or DA. Bias was -0.8{+-}1.0%, +5.0{+-}1.1 {mu}m, -5.9{+-}6.3 {mu}m, and -5.7{+-}29.1 {mu}m for BV/TV, Tb.Th*, Tb.Th, and Tb.Sp, respectively, and the differences did not vary over the range of values. Although systematic differences were noted between SR{mu}CT and C{mu}CT values, correlations between the techniques were high and the differences would probably not change the discrimination between study groups. C{mu}CT provides a reliable 3D assessment of human defatted bone when working at the 0.23 deg. or 0.45 deg. rotation step; the 0.9 deg. rotation step may be insufficiently accurate for morphological bone analysis.« less
Microcomputers in Florida Public Schools. Fall 1991. MIS Statistical Brief, Series 92-06B.
ERIC Educational Resources Information Center
Parks, Brenda; Bennett, Karen
This statistical brief on microcomputers in Florida public schools includes data on the following: (1) the number of instructional microcomputers from 1987-88 to 1991-92; (2) the number of instructional microcomputers for each school district from 1987-88 to 1991-92, including net change from 1990-91 to 1991-92; (3) percentages of instructional…
Microcomputers in Florida Public Schools. Fall 1990. MIS Statistical Brief, Series 91-07B.
ERIC Educational Resources Information Center
Florida State Dept. of Education, Tallahassee. Bureau of Program Support Services.
This summary of the use of microcomputers in Florida public schools during the 1990-91 school year indicates that the schools have reported a total of 131,367 microcomputers being used for student instruction, and 21,806 being used for administrative purposes. Four tables present data on the number of microcomputers in individual school districts…
ERIC Educational Resources Information Center
Vanderheiden, Gregg C.
The paper analyzes major microcomputer systems and their use in rehabilitative systems for persons with physical handicaps. Four categories of microcomputers are addressed: systems designed for home or school with emphasis on low cost, recreation, and educational software; general purpose microcomputers with applications in a large number of…
A Method for Evaluation of Microcomputers for Tactical Applications.
1980-06-01
application. The computational requirements of a tactical application are specified in terms of performance parameters. The presently marketed microcomputer...computational requirements of a tactical application are specified in terms of performance parameters. The presently marketed microcomputer and multi...also to provide a method to evaluate microcomputer systems for tactical applications, i.e., Command Control Communications (C 3), weapon systems, etc
A microcomputer network for control of a continuous mining machine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schiffbauer, W.H.
1993-12-31
This report details a microcomputer-based control and monitoring network that was developed in-house by the U.S. Bureau of Mines and installed on a continuous mining machine. The network consists of microcomputers that are connected together via a single twisted-pair cable. Each microcomputer was developed to provide a particular function in the control process. Machine-mounted microcomputers, in conjunction with the appropriate sensors, provide closed-loop control of the machine, navigation, and environmental monitoring. Off-the-machine microcomputers provide remote control of the machine, sensor status, and a connection to the network so that external computers can access network data and control the continuous miningmore » machine. Because of the network`s generic structure, it can be installed on most mining machines.« less
Practical applications of remote sensing technology
NASA Technical Reports Server (NTRS)
Whitmore, Roy A., Jr.
1990-01-01
Land managers increasingly are becoming dependent upon remote sensing and automated analysis techniques for information gathering and synthesis. Remote sensing and geographic information system (GIS) techniques provide quick and economical information gathering for large areas. The outputs of remote sensing classification and analysis are most effective when combined with a total natural resources data base within the capabilities of a computerized GIS. Some examples are presented of the successes, as well as the problems, in integrating remote sensing and geographic information systems. The need to exploit remotely sensed data and the potential that geographic information systems offer for managing and analyzing such data continues to grow. New microcomputers with vastly enlarged memory, multi-fold increases in operating speed and storage capacity that was previously available only on mainframe computers are a reality. Improved raster GIS software systems have been developed for these high performance microcomputers. Vector GIS systems previously reserved for mini and mainframe systems are available to operate on these enhanced microcomputers. One of the more exciting areas that is beginning to emerge is the integration of both raster and vector formats on a single computer screen. This technology will allow satellite imagery or digital aerial photography to be presented as a background to a vector display.
Talamo, Thomas S.; Losos, Frank J.; Mercer, Donald W.
1984-01-01
We have developed a microcomputer based system for interpretative reporting of creatine kinase (CK) and lactate dehydrogenase (LDH) isoenzyme studies. Patient demographic data and test results (total CK, CK-MB, LD-1, and LD-2) are entered manually through the keyboard. The test results are compared with normal range values and an interpretative report is generated. This report consists of all pertinent demographic information with a graphic display of up to 12 previous CK and LDH isoenzyme determinations. Diagnostic interpretative statements are printed beneath the graphic display following analysis of previously entered test results. The combination of graphic data display and interpretations based on analysis of up to 12 previous specimens provides useful and accurate information to the cardiologist.
Automated Power Systems Management (APSM)
NASA Technical Reports Server (NTRS)
Bridgeforth, A. O.
1981-01-01
A breadboard power system incorporating autonomous functions of monitoring, fault detection and recovery, command and control was developed, tested and evaluated to demonstrate technology feasibility. Autonomous functions including switching of redundant power processing elements, individual load fault removal, and battery charge/discharge control were implemented by means of a distributed microcomputer system within the power subsystem. Three local microcomputers provide the monitoring, control and command function interfaces between the central power subsystem microcomputer and the power sources, power processing and power distribution elements. The central microcomputer is the interface between the local microcomputers and the spacecraft central computer or ground test equipment.
Vo, T D; Dwyer, G; Szeto, H H
1986-04-01
A relatively powerful and inexpensive microcomputer-based system for the spectral analysis of the EEG is presented. High resolution and speed is achieved with the use of recently available large-scale integrated circuit technology with enhanced functionality (INTEL Math co-processors 8087) which can perform transcendental functions rapidly. The versatility of the system is achieved with a hardware organization that has distributed data acquisition capability performed by the use of a microprocessor-based analog to digital converter with large resident memory (Cyborg ISAAC-2000). Compiled BASIC programs and assembly language subroutines perform on-line or off-line the fast Fourier transform and spectral analysis of the EEG which is stored as soft as well as hard copy. Some results obtained from test application of the entire system in animal studies are presented.
ERIC Educational Resources Information Center
Toong, Hoo-min D.; Gupta, Amar
1982-01-01
Describes the hardware, software, applications, and current proliferation of personal computers (microcomputers). Includes discussions of microprocessors, memory, output (including printers), application programs, the microcomputer industry, and major microcomputer manufacturers (Apple, Radio Shack, Commodore, and IBM). (JN)
Picking through Microcomputer Books.
ERIC Educational Resources Information Center
Lu, Cary
1984-01-01
Indicating that most microcomputer books aren't worth reading, offers several rules of thumb for selecting a microcomputer guide. Also provides a list of 13 noteworthy books, providing title, source, and current cost. (JN)
ERIC Educational Resources Information Center
Watson, Nancy Ralph, Ed.
The 30 conference papers in this collection are presented in 6 categories. Five overviews discuss innovative uses of computers in education (Dorothy K. Deringer); microcomputers in instructional research (Alan M. Lesgold); microcomputers in the schools (Mitchell Batoff, Gary G. Bitter); and the courseware crisis (Barbara R. Sadowski). Research and…
Choosing a Microcomputer: A Success Story.
ERIC Educational Resources Information Center
Mason, Robert M.
1983-01-01
Documentation of author's personal experience in the purchasing of a microcomputer discusses background learning, the purchase decision, needs assessment, computer literacy, general information on microcomputers, the situation assessment, and the final check. (EJS)
ERIC Educational Resources Information Center
Marcum, Deanna; Boss, Richard
1983-01-01
Relates office automation to its application in libraries, discussing computer software packages for microcomputers performing tasks involved in word processing, accounting, statistical analysis, electronic filing cabinets, and electronic mail systems. (EJS)
Microcomputer Software Development: New Strategies for a New Technology.
ERIC Educational Resources Information Center
Kehrberg, Kent T.
1979-01-01
Provides a guide for the development of educational computer programs for use on microcomputers. Making use of the features of microcomputers, including visual, audio, and tactile techniques, is encouraged. (Author/IRT)
Applications of microcomputers in bridge design.
DOT National Transportation Integrated Search
1986-01-01
The utilization of microcomputers in bridge design activities in state transportation departments was evaluated through contacts with 32 state agencies. While the present utilization of microcomputers was found to be limited, subsequent research show...
Micro-CT features of intermediate gunshot wounds covered by textiles.
Giraudo, Chiara; Fais, Paolo; Pelletti, Guido; Viero, Alessia; Miotto, Diego; Boscolo-Berto, Rafael; Viel, Guido; Montisci, Massimo; Cecchetto, Giovanni; Ferrara, Santo Davide
2016-09-01
The analysis of gunshot residue (GSR) on the clothing and the underlying skin of the victim may play an important role in the reconstruction of the shooting incident. The aim of the present study was to test micro-computed tomography (micro-CT) for the analysis of firearm wounds experimentally produced on human skin covered by textiles. Firing trials were performed on 60 sections of human calves enveloped by a single layer of fabric (cotton or jeans or leather or nylon) and 15 controls consisting of bare calves. Experimental firings were conducted in a ballistic laboratory at three different muzzle-to-target distances (5, 15, and 30 cm), using a .32 ACP pistol (Beretta Mod. 81) loaded with full-jacketed bullets coming from the same production lot (7.65 × 17 mm, Browning SR). The visual inspection revealed the classic pattern of GSR distribution on the fabrics and the skin of control samples, while only a dark ring around the entrance lesion was identified on the skin beneath the fabrics. Micro-CT analysis showed the presence of radiopaque material on all entrance wounds, with a statistically significant difference between cases and controls. No differences were found among specimens covered by fabrics, with regard to the firing distance and the type of clothing. No GSR-like deposits were detected in exit wounds. Our results suggest that micro-CT analysis may be a useful screening tool for differentiating entry from exit gunshot wounds when the covering textiles are contaminated, damaged, or missing.
Grande, Nicola M; Plotino, Gianluca; Gambarini, Gianluca; Testarelli, Luca; D'Ambrosio, Ferdinando; Pecci, Raffaella; Bedini, Rossella
2012-01-01
The goal of the present article is to illustrate and analyze the applications and the potential of microcomputed tomography (micro-CT) in the analysis of tooth anatomy and root canal morphology. The authors performed a micro-CT analysis of the following different teeth: maxillary first molars with a second canal in the mesiobuccal (MB) root, mandibular first molars with complex anatomy in the mesial root, premolars with single and double roots and with complicated apical anatomy. The hardware device used in this study was a desktop X-ray microfocus CT scanner (SkyScan 1072, SkyScan bvba, Aartselaar, Belgium). A specific software ResolveRT Amira (Visage Imaging) was used for the 3D analysis and imaging. The authors obtained three-dimensional images from 15 teeth. It was possible to precisely visualize and analyze external and internal anatomy of teeth, showing the finest details. Among the 5 upper molars analyzed, in three cases, the MB canals joined into one canal, while in the other two molars the two mesial canals were separate. Among the lower molars two of the five samples exhibited a single canal in the mesial root, which had a broad, flat appearance in a mesiodistal dimension. In the five premolar teeth, the canals were independent; however, the apical delta and ramifications of the root canals were quite complex. Micro-CT offers a simple and reproducible technique for 3D noninvasive assessment of the anatomy of root canal systems.
ERIC Educational Resources Information Center
Library Computing, 1985
1985-01-01
Special supplement to "Library Journal" and "School Library Journal" covers topics of interest to school, public, academic, and special libraries planning for automation: microcomputer use, readings in automation, online searching, databases of microcomputer software, public access to microcomputers, circulation, creating a…
ERIC Educational Resources Information Center
Myers, Darlene
1983-01-01
Discusses development of the first computers; identifies five generations of computers; reviews projections for sales and proliferation of microcomputers into the marketplace; outlines procedures for selecting microcomputers and evaluating software; and reviews several articles on microcomputers centering on user requirements. (MBR)
Micromechanics of Sea Urchin Spines
Tsafnat, Naomi; Fitz Gerald, John D.; Le, Hai N.; Stachurski, Zbigniew H.
2012-01-01
The endoskeletal structure of the Sea Urchin, Centrostephanus rodgersii, has numerous long spines whose known functions include locomotion, sensing, and protection against predators. These spines have a remarkable internal microstructure and are made of single-crystal calcite. A finite-element model of the spine’s unique porous structure, based on micro-computed tomography (microCT) and incorporating anisotropic material properties, was developed to study its response to mechanical loading. Simulations show that high stress concentrations occur at certain points in the spine’s architecture; brittle cracking would likely initiate in these regions. These analyses demonstrate that the organization of single-crystal calcite in the unique, intricate morphology of the sea urchin spine results in a strong, stiff and lightweight structure that enhances its strength despite the brittleness of its constituent material. PMID:22984468
Micro-structural integrity of dental enamel subjected to two tooth whitening regimes.
Tanaka, Reina; Shibata, Yo; Manabe, Atsufumi; Miyazaki, Takashi
2010-04-01
Colour modification of tooth enamel has proven successful, but it is unclear how various bleaching applications affect micro-structural integrity of the whitened enamel. To investigate the internal structural integrity of human intact tooth enamel with the application of two commonly used whitening regimes (in-office power bleaching with 35% hydrogen peroxide and home bleaching with 10% carbamide peroxide), evaluations were performed on teeth of identical colour classification. After the bleaching applications, the enamel mineral density was quantified and visualised with micro-computed tomography. The micro-structural differences between the whitened tooth enamel samples were distinctive, though the colour parameter changes within the samples were equivalent. Home bleaching achieved colour modification by demineralisation, whereas in-office bleaching depended on redistribution of the minerals after treatment and subsequent enhanced mineralisation.
NASA Astrophysics Data System (ADS)
2008-12-01
Strength through structure The visualization and assessment of inner human bone structures can provide better predictions of fracture risk due to osteoporosis. Using micro-computed tomography (µCT), Christoph Räth from the Max Planck Institute for Extraterrestrial Physics and colleagues based in Munich, Vienna and Salzburg have shown how complex lattice-shaped bone structures can be visualized. The structures were quantified by calculating certain "texture measures" that yield new information about the stability of the bone. A 3D visualization showing the variation with orientation of one of the texture measures for four different bone specimens (from left to right) is shown above. Such analyses may help us to improve our understanding of disease and drug-induced changes in bone structure (C Räth et al. 2008 New J. Phys. 10 125010).
Computer-based analysis of microvascular alterations in a mouse model for Alzheimer's disease
NASA Astrophysics Data System (ADS)
Heinzer, Stefan; Müller, Ralph; Stampanoni, Marco; Abela, Rafael; Meyer, Eric P.; Ulmann-Schuler, Alexandra; Krucker, Thomas
2007-03-01
Vascular factors associated with Alzheimer's disease (AD) have recently gained increased attention. To investigate changes in vascular, particularly microvascular architecture, we developed a hierarchical imaging framework to obtain large-volume, high-resolution 3D images from brains of transgenic mice modeling AD. In this paper, we present imaging and data analysis methods which allow compiling unique characteristics from several hundred gigabytes of image data. Image acquisition is based on desktop micro-computed tomography (µCT) and local synchrotron-radiation µCT (SRµCT) scanning with a nominal voxel size of 16 µm and 1.4 µm, respectively. Two visualization approaches were implemented: stacks of Z-buffer projections for fast data browsing, and progressive-mesh based surface rendering for detailed 3D visualization of the large datasets. In a first step, image data was assessed visually via a Java client connected to a central database. Identified characteristics of interest were subsequently quantified using global morphometry software. To obtain even deeper insight into microvascular alterations, tree analysis software was developed providing local morphometric parameters such as number of vessel segments or vessel tortuosity. In the context of ever increasing image resolution and large datasets, computer-aided analysis has proven both powerful and indispensable. The hierarchical approach maintains the context of local phenomena, while proper visualization and morphometry provide the basis for detailed analysis of the pathology related to structure. Beyond analysis of microvascular changes in AD this framework will have significant impact considering that vascular changes are involved in other neurodegenerative diseases as well as in cancer, cardiovascular disease, asthma, and arthritis.
ERIC Educational Resources Information Center
Grice, R. D.
1986-01-01
The nature of literacy associated with the widely used new medium of microcomputers has not been fully exploited by schools to foster development of literacy programs. Microcomputer applications need integration with classroom activities where students construct language meaning. (19 references) (CJH)
Impact of Personal Computing on Education.
ERIC Educational Resources Information Center
McIsaac, Donald N.
1979-01-01
Describes microcomputers, outlines lessons learned from the evolution of other technologies as they apply to the development of the microcomputer, discusses computer literacy as a problem-solving tool, and speculates about microcomputer use in instruction and administration. (IRT)
[General-purpose microcomputer for medical laboratory instruments].
Vil'ner, G A; Dudareva, I E; Kurochkin, V E; Opalev, A A; Polek, A M
1984-01-01
Presented in the paper is the microcomputer based on the KP580 microprocessor set. Debugging of the hardware and the software by using the unique debugging stand developed on the basis of microcomputer "Electronica-60" is discussed.
Circulation Systems on Microcomputers.
ERIC Educational Resources Information Center
Carlson, Gary
1984-01-01
Reports on the use of microcomputers in comprehensive library circulation systems. Topics covered include system requirements (reliability, completeness); determining circulation system needs (saving money, improving service, modernization); limitations of microcomputers (capacity, kinds of data stored, number of stations or terminals); system…
Microcomputer network for control of a continuous mining machine. Information circular/1993
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schiffbauer, W.H.
1993-01-01
The paper details a microcomputer-based control and monitoring network that was developed in-house by the U.S. Bureau of Mines, and installed on a Joy 14 continuous mining machine. The network consists of microcomputers that are connected together via a single twisted pair cable. Each microcomputer was developed to provide a particular function in the control process. Machine-mounted microcomputers in conjunction with the appropriate sensors provide closed-loop control of the machine, navigation, and environmental monitoring. Off-the-machine microcomputers provide remote control of the machine, sensor status, and a connection to the network so that external computers can access network data and controlmore » the continuous mining machine. Although the network was installed on a Joy 14 continuous mining machine, its use extends beyond it. Its generic structure lends itself to installation onto most mining machine types.« less
Multi-modal porous microstructure for high temperature fuel cell application
NASA Astrophysics Data System (ADS)
Wejrzanowski, T.; Haj Ibrahim, S.; Cwieka, K.; Loeffler, M.; Milewski, J.; Zschech, E.; Lee, C.-G.
2018-01-01
In this study, the effect of microstructure of porous nickel electrode on the performance of high temperature fuel cell is investigated and presented based on a molten carbonate fuel cell (MCFC) cathode. The cathode materials are fabricated from slurry consisting of nickel powder and polymeric binder/solvent mixture, using the tape casting method. The final pore structure is shaped through modifying the slurry composition - with or without the addition of porogen(s). The manufactured materials are extensively characterized by various techniques involving: micro-computed tomography (micro-XCT), scanning electron microscopy (SEM), mercury porosimetry, BET and Archimedes method. Tomographic images are also analyzed and quantified to reveal the evolution of pore space due to nickel in situ oxidation to NiO, and infiltration by the electrolyte. Single-cell performance tests are carried out under MCFC operation conditions to estimate the performance of the manufactured materials. It is found that the multi-modal microstructure of MCFC cathode results in a significant enhancement of the power density generated by the reference cell. To give greater insight into the understanding of the effect of microstructure on the properties of the cathode, a model based on 3D tomography image transformation is proposed.
Blood-pool contrast agent for pre-clinical computed tomography
NASA Astrophysics Data System (ADS)
Cruje, Charmainne; Tse, Justin J.; Holdsworth, David W.; Gillies, Elizabeth R.; Drangova, Maria
2017-03-01
Advances in nanotechnology have led to the development of blood-pool contrast agents for micro-computed tomography (micro-CT). Although long-circulating nanoparticle-based agents exist for micro-CT, they are predominantly based on iodine, which has a low atomic number. Micro-CT contrast increases when using elements with higher atomic numbers (i.e. lanthanides), particularly at higher energies. The purpose of our work was to develop and evaluate a lanthanide-based blood-pool contrast agent that is suitable for in vivo micro-CT. We synthesized a contrast agent in the form of polymer-encapsulated Gd nanoparticles and evaluated its stability in vitro. The synthesized nanoparticles were shown to have an average diameter of 127 +/- 6 nm, with good size dispersity. Particle size distribution - evaluated by dynamic light scattering over the period of two days - demonstrated no change in size of the contrast agent in water and saline. Additionally, our contrast agent was stable in a mouse serum mimic for up to 30 minutes. CT images of the synthesized contrast agent (containing 27 mg/mL of Gd) demonstrated an attenuation of over 1000 Hounsfield Units. This approach to synthesizing a Gd-based blood-pool contrast agent promises to enhance the capabilities of micro-CT imaging.
Wang, Zhifa; Hu, Hanqing; Li, Zhijin; Weng, Yanming; Dai, Taiqiang; Zong, Chunlin; Liu, Yanpu; Liu, Bin
2016-04-01
Techniques that use sheets of cells have been successfully used in various types of tissue regeneration, and platelet-rich fibrin (PRF) can be used as a source of growth factors to promote angiogenesis. We have investigated the effects of the combination of PRF and sheets of mesenchymal stem cells (MSC) from bone marrow on the restoration of bone in critical-size calvarial defects in rabbits to find out whether the combination promotes bony healing. Sheets of MSC and PRF were prepared from the same donor. We then implanted the combined MSC and PRF in critical-size calvarial defects in rabbits and assessed bony restoration by microcomputed tomography (microCT) and histological analysis. The results showed that PRF significantly increased bony regeneration at 8 weeks after implantation of sheets of MSC and PRF compared with sheets of MSC alone (p=0.0048). Our results indicate that the combination of sheets of MSC and PRF increases bone regeneration in critical-size calvarial defects in rabbits, and provides a new way to improve skeletal healing. Copyright © 2015 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.
Three-Dimensional Analysis of the Fundus of the Human Internal Acoustic Canal.
Schart-Morén, Nadine; Larsson, Sune; Rask-Andersen, Helge; Li, Hao
Documentation of the nerve components in the internal acoustic canal is essential before cochlea implantation surgery. Interpretations may be challenged by wide anatomical variations of the VIIIth nerve and their ramifications. Malformations may further defy proper nerve identification. Using microcomputed tomography, we analyzed the fundus bone channels in an archival collection of 113 macerated human temporal bones and 325 plastic inner molds. Data were subsequently processed by volume-rendering software using a bony tissue algorithm. Three-dimensional reconstructions were made, and through orthogonal sections, the topographic anatomy was established. The technique provided additional information regarding the anatomy of the nerve foramina/channels of the human fundus region, including variations and destinations. Channel anastomosis were found beyond the level of the fundus. A foramen of the transverse crest was identified. Three-dimensional reconstructions and cropping outlined the bone canals and demonstrated the highly variable VIIIth nerve anatomy at the fundus of the human inner acoustic canal. Myriad channel interconnections suggested an intricate system of neural interactive pathways in humans. Particularly striking was the variable anatomy of the saccule nerve channels. The results may assist in the preoperative interpretation of the VIIIth nerve anatomy.
Visualization of superparamagnetic nanoparticles in vascular tissue using XμCT and histology.
Tietze, Rainer; Rahn, Helene; Lyer, Stefan; Schreiber, Eveline; Mann, Jenny; Odenbach, Stefan; Alexiou, Christoph
2011-02-01
In order to increase the dose of antineoplastic agents in the tumor area, the concept of magnetic drug targeting (MDT) has been developed. Magnetic nanoparticles consisting of iron oxide and a biocompatible cover layer suspended in an aqueous solution (ferrofluid) serve as carriers for chemotherapeutics being enriched by an external magnetic field after intra-arterial application in desired body compartments (i.e., tumor). We established an ex vivo model to simulate in vivo conditions in a circulating system consisting of magnetic iron oxide nanoparticles passing an intact bovine artery and being focused by an external magnetic field to study their distribution in the vessel. Micro-computed X-ray tomography (XμCT) and histology can elucidate the arrangement of these particles after application. XμCT-analysis has been performed on arterial sections after MDT in order to determine the distribution of the nanoparticles. These measurements have been carried out with a cone X-ray source and corresponding histological sections were stained with Prussian blue. It could be shown that combining XμCT and histology offers the opportunity for a better understanding of the mechanisms of nanoparticle deposition in the vascular system after MDT.
Self-fitting shape memory polymer foam inducing bone regeneration: A rabbit femoral defect study.
Xie, Ruiqi; Hu, Jinlian; Hoffmann, Oskar; Zhang, Yuanchi; Ng, Frankie; Qin, Tingwu; Guo, Xia
2018-04-01
Although tissue engineering has been attracted greatly for healing of critical-sized bone defects, great efforts for improvement are still being made in scaffold design. In particular, bone regeneration would be enhanced if a scaffold precisely matches the contour of bone defects, especially if it could be implanted into the human body conveniently and safely. In this study, polyurethane/hydroxyapatite-based shape memory polymer (SMP) foam was fabricated as a scaffold substrate to facilitate bone regeneration. The minimally invasive delivery and the self-fitting behavior of the SMP foam were systematically evaluated to demonstrate its feasibility in the treatment of bone defects in vivo. Results showed that the SMP foam could be conveniently implanted into bone defects with a compact shape. Subsequently, it self-matched the boundary of bone defects upon shape-recovery activation in vivo. Micro-computed tomography determined that bone ingrowth initiated at the periphery of the SMP foam with a constant decrease towards the inside. Successful vascularization and bone remodeling were also demonstrated by histological analysis. Thus, our results indicate that the SMP foam demonstrated great potential for bone regeneration. Copyright © 2018 Elsevier B.V. All rights reserved.
Characterization of cosmetic sticks at Xiaohe Cemetery in early Bronze Age Xinjiang, China
NASA Astrophysics Data System (ADS)
Mai, Huijuan; Yang, Yimin; Abuduresule, Idelisi; Li, Wenying; Hu, Xingjun; Wang, Changsui
2016-01-01
Cosmetics have been studied for a long time in the society and culture research, and its consumption is regarded as a cultural symbol of human society. This paper focuses on the analysis of the red cosmetic sticks, found in Xiaohe Cemetery (1980-1450BC), Xinjiang, China. The structure of the red cosmetic sticks was disclosed by SR-μCT scanning (Synchrotron Radiation Micro-computed Tomography), while the chemical components were characterized by FTIR (Fourier Transform Infrared Spectroscopy), Raman Spectroscopy and Proteomics. The results suggested that the cosmetic sticks were made from the cattle heart and covered with a layer of hematite powders as the pigment. Given the numerous red painted relics in Xiaohe Cemetery, this kind of cosmetic sticks might be used as a primitive form of crayon for makeup and painting. The usage of cattle hearts as cosmetic sticks is firstly reported up to our knowledge, which not only reveals the varied utilizations of cattle in Xiaohe Cemetery but also shows the distinctive religious function. Furthermore, these red cosmetic sticks were usually buried with women, implying that the woman may be the painter and play a special role in religious activities.
NASA Astrophysics Data System (ADS)
Wang, X.; Meier, D.; Oya, P.; Maehlum, G. E.; Wagenaar, D. J.; Tsui, B. M. W.; Patt, B. E.; Frey, E. C.
2010-04-01
The overall aim of this work was to evaluate the potential for improving in vivo small animal microCT through the use of an energy resolved photon-counting detector. To this end, we developed and evaluated a prototype microCT system based on a second-generation photon-counting x-ray detector which simultaneously counted photons with energies above six energy thresholds. First, we developed a threshold tuning procedure to reduce the dependence of detector uniformity and to reduce ring artifacts. Next, we evaluated the system in terms of the contrast-to-noise ratio in different energy windows for different target materials. These differences provided the possibility to weight the data acquired in different windows in order to optimize the contrast-to-noise ratio. We also explored the ability of the system to use data from different energy windows to aid in distinguishing various materials. We found that the energy discrimination capability provided the possibility for improved contrast-to-noise ratios and allowed separation of more than two materials, e.g., bone, soft-tissue and one or more contrast materials having K-absorption edges in the energy ranges of interest.
Kuroda, Yukiko; Yonemitsu, Ikuo; Hosomichi, Jun; Watari, Ippei; Takei, Maki; Ishida, Yuji; Ono, Takashi
2011-11-01
To examine whether intermittent posterior condylar displacement causes changes in cancellous bone in the mandibular condyle during the growth period. Sixteen 5-week-old male Wistar rats were divided into experimental and control groups. In the experimental group, an appliance was attached to the maxillary incisors to induce posterior displacement of the condyles in the occluded condition. Untreated rats served as the control group. Animals were sacrificed at 14 days, and the condyles were removed to analyze the three-dimensional cancellous bone structure by microcomputed tomography (micro-CT). Serial sagittal paraffin sections of the condyles were used for hematoxylin and eosin staining to investigate histomorphological changes and for tartrate-resistant acid phosphatase (TRAP) staining to identify osteoclastic cells. Micro-CT analysis showed that in the experimental group, the bone volume fraction and the degree of anisotropy were significantly decreased compared with those in the control group in the anterior region of the condyle. Moreover, the number of TRAP-positive cells was significantly greater in the same region in the experimental group than in the control group. Intermittent posterior displacement of the mandible can cause region-specific changes in the profile and microarchitecture of the condylar cancellous bone.
Creep of trabecular bone from the human proximal tibia
Novitskaya, Ekaterina; Zin, Carolyn; Chang, Neil; Cory, Esther; Chen, Peter; D'Lima, Darryl; Sah, Robert L.; McKittrick, Joanna
2014-01-01
Creep is the deformation that occurs under a prolonged, sustained load and can lead to permanent damage in bone. Creep in bone is a complex phenomenon and varies with type of loading and local mechanical properties. Human trabecular bone samples from proximal tibia were harvested from a 71-year old female cadaver with osteoporosis. The samples were initially subjected to one cycle load up to 1% strain to determine the creep load. Samples were then loaded in compression under a constant stress for two hours and immediately unloaded. All tests were conducted with the specimens soaked in phosphate buffered saline with proteinase inhibitors at 37°C. Steady state creep rate and final creep strain were estimated from mechanical testing and compared with published data. The steady state creep rate correlated well with values obtained from bovine tibial and human vertebral trabecular bone, and was higher for lower density samples. Tissue architecture was analyzed by micro-computed tomography (μCT) both before and after creep testing to assess creep deformation and damage accumulated. Quantitative morphometric analysis indicated that creep induced changes in trabecular separation and the structural model index. A main mode of deformation was bending of trabeculae. PMID:24857486
Improved 3D skeletonization of trabecular bone images derived from in vivo MRI
NASA Astrophysics Data System (ADS)
Magland, Jeremy F.; Wehrli, Felix W.
2008-03-01
Independent of overall bone density, 3D trabecular bone (TB) architecture has been shown to play an important role in conferring strength to the skeleton. Advances in imaging technologies such as micro-computed tomography (CT) and micro-magnetic resonance (MR) now permit in vivo imaging of the 3D trabecular network in the distal extremities. However, various experimental factors preclude a straightforward analysis of the 3D trabecular structure on the basis of these in vivo images. For MRI, these factors include blurring due to patient motion, partial volume effects, and measurement noise. While a variety of techniques have been developed to deal with the problem of patient motion, the second and third issues are inherent limitations of the modality. To address these issues, we have developed a series of robust processing steps to be applied to a 3D MR image and leading to a 3D skeleton that accurately represents the trabecular bone structure. Here we describe the algorithm, provide illustrations of its use with both specimen and in vivo micro-MR images, and discuss the accuracy and quantify the relationship between the original bone structure and the resulting 3D skeleton volume.
Dobrivojević, Marina; Bohaček, Ivan; Erjavec, Igor; Gorup, Dunja; Gajović, Srećko
2013-01-01
Aim To explore the possibility of brain imaging by microcomputed tomography (microCT) using x-ray contrasting methods to visualize mouse brain ischemic lesions after middle cerebral artery occlusion (MCAO). Methods Isolated brains were immersed in ionic or nonionic radio contrast agent (RCA) for 5 days and subsequently scanned using microCT scanner. To verify whether ex-vivo microCT brain images can be used to characterize ischemic lesions, they were compared to Nissl stained serial histological sections of the same brains. To verify if brains immersed in RCA may be used afterwards for other methods, subsequent immunofluorescent labeling with anti-NeuN was performed. Results Nonionic RCA showed better gray to white matter contrast in the brain, and therefore was selected for further studies. MicroCT measurement of ischemic lesion size and cerebral edema significantly correlated with the values determined by Nissl staining (ischemic lesion size: P=0.0005; cerebral edema: P=0.0002). Brain immersion in nonionic RCA did not affect subsequent immunofluorescent analysis and NeuN immunoreactivity. Conclusion MicroCT method was proven to be suitable for delineation of the ischemic lesion from the non-infarcted tissue, and quantification of lesion volume and cerebral edema. PMID:23444240
Dobrivojević, Marina; Bohaček, Ivan; Erjavec, Igor; Gorup, Dunja; Gajović, Srećko
2013-02-01
To explore the possibility of brain imaging by microcomputed tomography (microCT) using x-ray contrasting methods to visualize mouse brain ischemic lesions after middle cerebral artery occlusion (MCAO). Isolated brains were immersed in ionic or nonionic radio contrast agent (RCA) for 5 days and subsequently scanned using microCT scanner. To verify whether ex-vivo microCT brain images can be used to characterize ischemic lesions, they were compared to Nissl stained serial histological sections of the same brains. To verify if brains immersed in RCA may be used afterwards for other methods, subsequent immunofluorescent labeling with anti-NeuN was performed. Nonionic RCA showed better gray to white matter contrast in the brain, and therefore was selected for further studies. MicroCT measurement of ischemic lesion size and cerebral edema significantly correlated with the values determined by Nissl staining (ischemic lesion size: P=0.0005; cerebral edema: P=0.0002). Brain immersion in nonionic RCA did not affect subsequent immunofluorescent analysis and NeuN immunoreactivity. MicroCT method was proven to be suitable for delineation of the ischemic lesion from the non-infarcted tissue, and quantification of lesion volume and cerebral edema.
Image analysis of pulmonary nodules using micro CT
NASA Astrophysics Data System (ADS)
Niki, Noboru; Kawata, Yoshiki; Fujii, Masashi; Kakinuma, Ryutaro; Moriyama, Noriyuki; Tateno, Yukio; Matsui, Eisuke
2001-07-01
We are developing a micro-computed tomography (micro CT) system for imaging pulmonary nodules. The purpose is to enhance the physician performance in accessing the micro- architecture of the nodule for classification between malignant and benign nodules. The basic components of the micro CT system consist of microfocus X-ray source, a specimen manipulator, and an image intensifier detector coupled to charge-coupled device (CCD) camera. 3D image reconstruction was performed by the slice. A standard fan- beam convolution and backprojection algorithm was used to reconstruct the center plane intersecting the X-ray source. The preprocessing of the 3D image reconstruction included the correction of the geometrical distortions and the shading artifact introduced by the image intensifier. The main advantage of the system is to obtain a high spatial resolution which ranges between b micrometers and 25 micrometers . In this work we report on preliminary studies performed with the micro CT for imaging resected tissues of normal and abnormal lung. Experimental results reveal micro architecture of lung tissues, such as alveolar wall, septal wall of pulmonary lobule, and bronchiole. From the results, the micro CT system is expected to have interesting potentials for high confidential differential diagnosis.
Inspection of additive manufactured parts using laser ultrasonics
NASA Astrophysics Data System (ADS)
Lévesque, D.; Bescond, C.; Lord, M.; Cao, X.; Wanjara, P.; Monchalin, J.-P.
2016-02-01
Additive manufacturing is a novel technology of high importance for global sustainability of resources. As additive manufacturing involves typically layer-by-layer fusion of the feedstock (wire or powder), an important characteristic of the fabricated metallic structural parts, such as those used in aero-engines, is the performance, which is highly related to the presence of defects, such as cracks, lack of fusion or bonding between layers, and porosity. For this purpose, laser ultrasonics is very attractive due to its non-contact nature and is especially suited for the analysis of parts of complex geometries. In addition, the technique is well adapted to online implementation and real-time measurement during the manufacturing process. The inspection can be performed from either the top deposited layer or the underside of the substrate and the defects can be visualized using laser ultrasonics combined with the synthetic aperture focusing technique (SAFT). In this work, a variety of results obtained off-line on INCONEL® 718 and Ti-6Al-4V coupons that were manufactured using laser powder, laser wire, or electron beam wire deposition are reported and most defects detected were further confirmed by X-ray micro-computed tomography.
Characterization of cosmetic sticks at Xiaohe Cemetery in early Bronze Age Xinjiang, China
Mai, Huijuan; Yang, Yimin; Abuduresule, Idelisi; Li, Wenying; Hu, Xingjun; Wang, Changsui
2016-01-01
Cosmetics have been studied for a long time in the society and culture research, and its consumption is regarded as a cultural symbol of human society. This paper focuses on the analysis of the red cosmetic sticks, found in Xiaohe Cemetery (1980–1450BC), Xinjiang, China. The structure of the red cosmetic sticks was disclosed by SR-μCT scanning (Synchrotron Radiation Micro-computed Tomography), while the chemical components were characterized by FTIR (Fourier Transform Infrared Spectroscopy), Raman Spectroscopy and Proteomics. The results suggested that the cosmetic sticks were made from the cattle heart and covered with a layer of hematite powders as the pigment. Given the numerous red painted relics in Xiaohe Cemetery, this kind of cosmetic sticks might be used as a primitive form of crayon for makeup and painting. The usage of cattle hearts as cosmetic sticks is firstly reported up to our knowledge, which not only reveals the varied utilizations of cattle in Xiaohe Cemetery but also shows the distinctive religious function. Furthermore, these red cosmetic sticks were usually buried with women, implying that the woman may be the painter and play a special role in religious activities. PMID:26820435
Characterization of cosmetic sticks at Xiaohe Cemetery in early Bronze Age Xinjiang, China.
Mai, Huijuan; Yang, Yimin; Abuduresule, Idelisi; Li, Wenying; Hu, Xingjun; Wang, Changsui
2016-01-28
Cosmetics have been studied for a long time in the society and culture research, and its consumption is regarded as a cultural symbol of human society. This paper focuses on the analysis of the red cosmetic sticks, found in Xiaohe Cemetery (1980-1450BC), Xinjiang, China. The structure of the red cosmetic sticks was disclosed by SR-μCT scanning (Synchrotron Radiation Micro-computed Tomography), while the chemical components were characterized by FTIR (Fourier Transform Infrared Spectroscopy), Raman Spectroscopy and Proteomics. The results suggested that the cosmetic sticks were made from the cattle heart and covered with a layer of hematite powders as the pigment. Given the numerous red painted relics in Xiaohe Cemetery, this kind of cosmetic sticks might be used as a primitive form of crayon for makeup and painting. The usage of cattle hearts as cosmetic sticks is firstly reported up to our knowledge, which not only reveals the varied utilizations of cattle in Xiaohe Cemetery but also shows the distinctive religious function. Furthermore, these red cosmetic sticks were usually buried with women, implying that the woman may be the painter and play a special role in religious activities.
Final report : evaluation of microcomputer applications in transportation engineering.
DOT National Transportation Integrated Search
1984-01-01
This study investigated areas where microcomputers can aid in the effectiveness of transportation engineering at state and local levels. A survey of the microcomputer needs of transportation professionals in state and local agencies in Virginia was c...
Microcomputer Database Management Systems for Bibliographic Data.
ERIC Educational Resources Information Center
Pollard, Richard
1986-01-01
Discusses criteria for evaluating microcomputer database management systems (DBMS) used for storage and retrieval of bibliographic data. Two popular types of microcomputer DBMS--file management systems and relational database management systems--are evaluated with respect to these criteria. (Author/MBR)
Size-exclusion chromatography system for macromolecular interaction analysis
Stevens, Fred J.
1988-01-01
A low pressure, microcomputer controlled system employing high performance liquid chromatography (HPLC) allows for precise analysis of the interaction of two reversibly associating macromolecules such as proteins. Since a macromolecular complex migrates faster than its components during size-exclusion chromatography, the difference between the elution profile of a mixture of two macromolecules and the summation of the elution profiles of the two components provides a quantifiable indication of the degree of molecular interaction. This delta profile is used to qualitatively reveal the presence or absence of significant interaction or to rank the relative degree of interaction in comparing samples and, in combination with a computer simulation, is further used to quantify the magnitude of the interaction in an arrangement wherein a microcomputer is coupled to analytical instrumentation in a novel manner.
NASA Technical Reports Server (NTRS)
Nauda, A.
1982-01-01
Performance and reliability models of alternate microcomputer architectures as a methodology for optimizing system design were examined. A methodology for selecting an optimum microcomputer architecture for autonomous operation of planetary spacecraft power systems was developed. Various microcomputer system architectures are analyzed to determine their application to spacecraft power systems. It is suggested that no standardization formula or common set of guidelines exists which provides an optimum configuration for a given set of specifications.
ERIC Educational Resources Information Center
Miles, Curtis
1983-01-01
Reviews sources of information on materials for teaching reasoning with a microcomputer. Suggests microcomputer magazines, catalogs of commercial materials, CONDUIT (a nonprofit organization devoted to educational computer use), and local microcomputer users groups. Lists Apple II software for strategy games with reasoning applications. (DMM)
Crean, Barry; Parker, Andrew; Roux, Delphine Le; Perkins, Mark; Luk, Shen Y; Banks, Simon R; Melia, Colin D; Roberts, Clive J
2010-11-01
X-ray micro-computed tomography (XMCT) was used in conjunction with confocal Raman mapping to measure the intra-granular pore size, binder volumes and to provide spatial and chemical maps of internal granular components in α-lactose monohydrate granules formulated with different molecular weights of polyvinyl pyrrolidone (PVP). Infrared spectroscopy was used to understand the molecular association of binder domains. Granules were prepared by high-shear aqueous granulation from α-lactose monohydrate and PVP K29/32 or K90. XMCT was used to visualise the granule microstructure, intra-granular binder distribution and measure intra-granular porosity, which was subsequently related to intrusion porosimetry measurements. Confocal Raman microscopy and infrared microscopy were employed to investigate the distribution of components within the granule and explore the nature of binder substrate interactions. XMCT data sets of internal granule microstructure provided values of residual porosity in the lactose:PVP K29/32 and lactose:PVP K90 granules of 32.41 ± 4.60% and 22.40 ± 0.03%, respectively. The binder volumes of the lactose:PVP K29/32 and lactose:PVP K90 granules were 2.98 ± 0.10% and 3.38 ± 0.07%, respectively, and were attributed to PVP-rich binder domains within the granule. Confocal Raman microscopy revealed anisotropic domains of PVP between 2 μm and 20 μm in size surrounded by larger particles of lactose, in both granule types. Raman data showed that PVP domains contained various amounts of lactose, whilst IR microscopy determined that the PVP was molecularly associated with lactose, rather than residual water. The work shows that XMCT can be applied to investigate granular microstructure and resolve the porosity and the excipient and binder volumes. Combining this technique with vibrational techniques provides further structural information and aids the interpretations of the XMCT images. When used complementarily, these techniques highlighted that porosity and binder volume were the most significant microstructural differences between the α-lactose monohydrate granules formulated with the different grades of PVP. Copyright © 2010 Elsevier B.V. All rights reserved.
Micro-computed tomography study of the internal anatomy of mesial root canals of mandibular molars.
Villas-Bôas, Marcelo Haas; Bernardineli, Norberti; Cavenago, Bruno Cavalini; Marciano, Marina; Del Carpio-Perochena, Aldo; de Moraes, Ivaldo Gomes; Duarte, Marco H; Bramante, Clovis M; Ordinola-Zapata, Ronald
2011-12-01
The aim of this study was to determine the mesiodistal and buccolingual diameter, apical volume, and the presence of isthmuses at the apical level of mesial root canals of mandibular molars. Sixty extracted first and second mandibular molars were scanned by using a SkyScan 1076 micro-computed tomography system with a voxel size of 18 μm. The apical thirds of the samples were reconstructed to allow a perpendicular section of the apical third by using the multiplanar reconstruction tool of the OsiriX software. The mesiodistal and the buccolingual distances of root canals were measured between the 1- to 4-mm levels. The type of root canal isthmuses present at these levels was classified by using modified criteria of Hsu and Kim. The volume of the root canal anatomy between the 1- to 3-mm apical levels was obtained by using the CTAN-CTVOL software. The medians of the mesiodistal diameter at the 1-, 2-, 3-, and 4-mm levels in the mesiobuccal and mesiolingual canals were 0.22 and 0.23 mm, 0.27 and 0.27 mm, 0.30 and 0.30 mm, and 0.36 and 0.35 mm, respectively. The buccolingual lengths at the 1-, 2-, 3-, and 4-mm levels were 0.37-0.35 mm, 0.55-0.41 mm, 0.54-0.49 mm, and 0.54 and 0.60 mm, respectively. The presence of isthmuses was more prevalent at the 3- to 4-mm level. However, 27 cases presented complete or incomplete isthmuses at the 1-mm apical level. The mean of the volume of the apical third was 0.83 mm(3), with a minimum value of 0.02 and a maximum value of 2.4 mm(3). Mesial root canals of mandibular molars do not present a consistent pattern. A high variability of apical diameters exists. The presence of isthmuses at the apical third was not uncommon even at the 1-mm apical level. Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Validation of cortical bone mineral density distribution using micro-computed tomography.
Mashiatulla, Maleeha; Ross, Ryan D; Sumner, D Rick
2017-06-01
Changes in the bone mineral density distribution (BMDD), due to disease or drugs, can alter whole bone mechanical properties such as strength, stiffness and toughness. The methods currently available for assessing BMDD are destructive and two-dimensional. Micro-computed tomography (μCT) has been used extensively to quantify the three-dimensional geometry of bone and to measure the mean degree of mineralization, commonly called the tissue mineral density (TMD). The TMD measurement has been validated to ash density; however parameters describing the frequency distribution of TMD have not yet been validated. In the current study we tested the ability of μCT to estimate six BMDD parameters: mean, heterogeneity (assessed by the full-width-at-half-maximum (FWHM) and the coefficient of variation (CoV)), the upper and lower 5% cutoffs of the frequency distribution, and peak mineralization) in rat sized femoral cortical bone samples. We used backscatter scanning electron microscopy (bSEM) as the standard. Aluminum and hydroxyapatite phantoms were used to identify optimal scanner settings (70kVp, and 57μA, with a 1500ms integration time). When using hydroxyapatite samples that spanned a broad range of mineralization levels, high correlations were found between μCT and bSEM for all BMDD parameters (R 2 ≥0.92, p<0.010). When using cortical bone samples from rats and various species machined to mimic rat cortical bone geometry, significant correlations between μCT and bSEM were found for mean mineralization (R 2 =0.65, p<0.001), peak mineralization (R 2 =0.61, p<0.001) the lower 5% cutoff (R 2 =0.62, p<0.001) and the upper 5% cutoff (R 2 =0.33, p=0.021), but not for heterogeneity, measured by FWHM (R 2 =0.05, p=0.412) and CoV (R 2 =0.04, p=0.469). Thus, while mean mineralization and most parameters used to characterize the BMDD can be assessed with μCT in rat sized cortical bone samples, caution should be used when reporting the heterogeneity. Copyright © 2017 Elsevier Inc. All rights reserved.
Characterization of Dilatant Shear Bands in Castlegate Sandstone Using Micro-Computed Tomography
NASA Astrophysics Data System (ADS)
Rosenthal, R. E.; Issen, K. A.; Richards, M. C.; Ingraham, M. D.
2016-12-01
Deformation bands in granular rock are thin tabular zones of localized shear and/or volumetric strain, which affect permeability and can impact fluid flow, extraction and storage. The present work characterizes dilatant shear bands formed in Castlegate sandstone (a high porosity reservoir analog) during true triaxial laboratory testing (Ingraham et al., 2013a) at low mean stresses. X-ray micro-computed tomography (micro-CT) scans produced 3-dimensional voxel files containing density information of tested specimens. Micro-CT data were thresholded to extract the least dense voxels, corresponding to pore space and localized dilation. Plane fits were determined by a custom algorithm that calculated the angle between the band normal and maximum compression direction. For tests at the same mean stress, the band angle is lower when intermediate principal stress approaches minimum compression and higher when it approaches maximum compression. Micro-CT band angles were compared to angles from the specimen jackets (Ingraham et al., 2013a), and band angles from plane fits through located acoustic emissions (AE) events (Ingraham et al. 2013b). For non-axisymmetric stress states (three unique principal stresses), one primary dilatant shear band formed in each specimen. Occasionally, secondary bands traversing part of the specimen were also identified. The principal band angles from the micro-CT scans were on average within 3 degrees of the jacket angles and within 9 degrees of AE angles. For axisymmetric stress states (intermediate principal stress equal to maximum or minimum compression) micro-CT results reveal multiple conjugate and/or parallel bands. Each jacket angle correlated to a micro-CT angle within 4 degrees. Micro-CT results also reveal that, regardless of stress state, each band is comprised of a network of interconnected pore space pathways meandering between grain clusters, as opposed to an opening fracture/joint. Ingraham MD, KA Issen, DJ Holcomb, 2013a, J. Geophys. Res. Solid Earth, Vol. 118, pp. 536-552, doi:10.1002/jgrb.50084. Ingraham MD, KA Issen, DJ Holcomb, 2013b, Acta Geotech., Vol. 8, Iss. 6, pp. 645-663, DOI: 10.1007/s11440-013-0275-y.
Wu, Andy T J; Turk, Tamer; Colak, Canan; Elekdağ-Turk, Selma; Jones, Allan S; Petocz, Peter; Darendeliler, M Ali
2011-05-01
The aim of this prospective randomized clinical trial was to quantitatively measure and compare the locations, dimensions, and volume of root resorption craters in human premolars after the application of controlled light and heavy rotational orthodontic forces over a 28-day (4-week) period. Fifteen patients requiring bilateral extraction of maxillary first premolars as part of their orthodontic treatment were recruited for this study. Each patient received a heavy (225 g) rotational force on 1 premolar and a light (25 g) rotational force on the contralateral premolar. Orthodontic rotational forces were applied over 28 days with buccal and palatal cantilever springs; 0.016-inch beta-titanium molybdenum alloys were used to apply the light force and 0.018-inch stainless steel was used for the heavy force. After the 28-day experimental period, the upper first premolars were extracted under stringent protocols to prevent root surface damage. The samples were then scanned using a microcomputed tomography (micro-CT) scan x-ray system (SkyScan 1072, Skyscan, Aartselaar, Belgium), and analyzed using convex hull algorithm (CHULL2D; University of Sydney, Sydney, Australia) software to obtain direct volumetric measurements. The mean volume of resorption craters was 0.42 in the light force group and 0.51 in the heavy force group (P = 0.013). When separated at the root level, the difference in volume of root resorption craters between the 2 groups was significantly different only at the midlevel (P = 0.001). Root resorption craters were consistently detected at the boundaries between the buccal and distal surfaces and the mesial and lingual surfaces. The result supports our hypothesis that positive areas develop significantly more root resorption craters at all 3 levels, as compared with minimal areas (paired t test <0.001). Heavy rotational forces caused more root resorption than light rotational forces and compression areas (buccal-distal and lingual-mesial surfaces in this study) showed significantly higher root resorption than other areas at all levels of the root. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
Betts, Duncan Colin; Müller, Ralph; Hofmann, Sandra
2017-01-01
Mechanical loading plays a major role in bone remodeling and fracture healing. Mimicking the concept of mechanical loading of bone has been widely studied in bone tissue engineering by perfusion cultures. Nevertheless, there is still debate regarding the in-vitro mechanical stimulation regime. This study aims at investigating the effect of two different flow rates (vlow = 0.001m/s and vhigh = 0.061m/s) on the growth of mineralized tissue produced by human mesenchymal stromal cells cultured on 3-D silk fibroin scaffolds. The flow rates applied were chosen to mimic the mechanical environment during early fracture healing or during bone remodeling, respectively. Scaffolds cultured under static conditions served as a control. Time-lapsed micro-computed tomography showed that mineralized extracellular matrix formation was completely inhibited at vlow compared to vhigh and the static group. Biochemical assays and histology confirmed these results and showed enhanced osteogenic differentiation at vhigh whereas the amount of DNA was increased at vlow. The biological response at vlow might correspond to the early stage of fracture healing, where cell proliferation and matrix production is prominent. Visual mapping of shear stresses, simulated by computational fluid dynamics, to 3-D micro-computed tomography data revealed that shear stresses up to 0.39mPa induced a higher DNA amount and shear stresses between 0.55mPa and 24mPa induced osteogenic differentiation. This study demonstrates the feasibility to drive cell behavior of human mesenchymal stromal cells by the flow velocity applied in agreement with mechanical loading mimicking early fracture healing (vlow) or bone remodeling (vhigh). These results can be used in the future to tightly control the behavior of human mesenchymal stromal cells towards proliferation or differentiation. Additionally, the combination of experiment and simulation presented is a strong tool to link biological responses to mechanical stimulation and can be applied to various in-vitro cultures to improve the understanding of the cause-effect relationship of mechanical loading. PMID:28686698
Microcomputer Competencies for Vocational Teachers.
ERIC Educational Resources Information Center
Roth, Gene L.; Tesolowski, Dennis G.
1984-01-01
This joint research and development project of two state departments of education used the DACUM (Developing a Curriculum) process to identify microcomputer competencies for vocational instructors. Brainstorming techniques were used to identify five categories of microcomputer applications and to determine which competencies belonged in each…
ERIC Educational Resources Information Center
Litaker, R. Gregory
The applications of a recently developed computer program for microcomputers in developing models in an institutional research environment are considered. The VISICALC program requires no user programming skills, is available for all major brands of microcomputers, and provides for easy exchange of information between users of different computing…
Measuring Thermoelectric Properties Automatically
NASA Technical Reports Server (NTRS)
Chmielewski, A.; Wood, C.
1986-01-01
Microcomputer-controlled system speeds up measurements of Hall voltage, Seebeck coefficient, and thermal diffusivity in semiconductor compounds for thermoelectric-generator applications. With microcomputer system, large data base of these parameters gathered over wide temperature range. Microcomputer increases measurement accuracy, improves operator productivity, and reduces test time.
Microcomputers, Evaluation, Literacy: Will the Teacher Survive?
ERIC Educational Resources Information Center
Hofmann, Richard J., Ed.
1982-01-01
The development of computer technology is considered, the concept of computer literacy is defined, and the role of teachers in educational microcomputer programs is discussed. The field of commercially produced software for microcomputers is reviewed. (For related articles, see EC 142 959-962.) (Author)
Implementing a Microcomputer Database Management System.
ERIC Educational Resources Information Center
Manock, John J.; Crater, K. Lynne
1985-01-01
Current issues in selecting, structuring, and implementing microcomputer database management systems in research administration offices are discussed, and their capabilities are illustrated with the system used by the University of North Carolina at Wilmington. Trends in microcomputer technology and their likely impact on research administration…
Single-chip microcomputer application in high-altitude balloon orientation system
NASA Technical Reports Server (NTRS)
Lim, T. S.; Ehrmann, C. H.; Allison, S. R.
1980-01-01
This paper describes the application of a single-chip microcomputer in a high-altitude balloon instrumentation system. The system, consisting of a magnetometer, a stepping motor, a microcomputer and a gray code shaft encoder, is used to provide an orientation reference to point a scientific instrument at an object in space. The single-chip microcomputer, Intel's 8748, consisting of a CPU, program memory, data memory and I/O ports, is used to control the orientation of the system.
Bi-directional communication interface for microprocessor-to-system/370
NASA Technical Reports Server (NTRS)
Fischer, J. P.
1981-01-01
The design and operation of a bi-directional communication interface between a microcomputer and the IBM System/370 is documented. The hardware unit interconnects a modem to interface to the S/370, the microcomputer with an EIA I/O port, and a terminal for sending and receiving data from either the microcomputer or the S/370. Also described is the software necessary for the two-way interface. This interface is designed so that no modifications need to be made to the terminal, modem, or microcomputer.
NASA Astrophysics Data System (ADS)
Vonlanthen, Pierre; Rausch, Juanita; Ketcham, Richard A.; Putlitz, Benita; Baumgartner, Lukas P.; Grobéty, Bernard
2015-02-01
The morphology of small volcanic ash particles is fundamental to our understanding of magma fragmentation, and in transport modeling of volcanic plumes and clouds. Until recently, the analysis of 3D features in small objects (< 250 μm) was either restricted to extrapolations from 2D approaches, partial stereo-imaging, or CT methods having limited spatial resolution and/or accessibility. In this study, an X-ray computed-tomography technique known as SEM micro-CT, also called 3D X-ray ultramicroscopy (3D XuM), was used to investigate the 3D morphology of small volcanic ash particles (125-250 μm sieve fraction), as well as their vesicle and microcrystal distribution. The samples were selected from four stratigraphically well-established tephra layers of the Meerfelder Maar (West Eifel Volcanic Field, Germany). Resolution tests performed on a Beametr v1 pattern sample along with Monte Carlo simulations of X-ray emission volumes indicated that a spatial resolution of 0.65 μm was obtained for X-ray shadow projections using a standard thermionic SEM and a bulk brass target as X-ray source. Analysis of a smaller volcanic ash particle (64-125 μm sieve fraction) showed that features with volumes > 20 μm3 (~ 3.5 μm in diameter) can be successfully reconstructed and quantified. In addition, new functionalities of the Blob3D software were developed to allow the particle shape factors frequently used as input parameters in ash transport and dispersion models to be calculated. This study indicates that SEM micro-CT is very well suited to quantify the various aspects of shape in fine volcanic ash, and potentially also to investigate the 3D morphology and internal structure of any object < 0.1 mm3.
NASA Astrophysics Data System (ADS)
McClatchy, David M., III; Rizzo, Elizabeth J.; Meganck, Jeff; Kempner, Josh; Vicory, Jared; Wells, Wendy A.; Paulsen, Keith D.; Pogue, Brian W.
2017-12-01
A multimodal micro-computed tomography (CT) and multi-spectral structured light imaging (SLI) system is introduced and systematically analyzed to test its feasibility to aid in margin delineation during breast conserving surgery (BCS). Phantom analysis of the micro-CT yielded a signal-to-noise ratio of 34, a contrast of 1.64, and a minimum detectable resolution of 240 μm for a 1.2 min scan. The SLI system, spanning wavelengths 490 nm to 800 nm and spatial frequencies up to 1.37 mm-1 , was evaluated with aqueous tissue simulating phantoms having variations in particle size distribution, scatter density, and blood volume fraction. The reduced scattering coefficient, μs\\prime and phase function parameter, γ, were accurately recovered over all wavelengths independent of blood volume fractions from 0% to 4%, assuming a flat sample geometry perpendicular to the imaging plane. The resolution of the optical system was tested with a step phantom, from which the modulation transfer function was calculated yielding a maximum resolution of 3.78 cycles per mm. The three dimensional spatial co-registration between the CT and optical imaging space was tested and shown to be accurate within 0.7 mm. A freshly resected breast specimen, with lobular carcinoma, fibrocystic disease, and adipose, was imaged with the system. The micro-CT provided visualization of the tumor mass and its spiculations, and SLI yielded superficial quantification of light scattering parameters for the malignant and benign tissue types. These results appear to be the first demonstration of SLI combined with standard medical tomography for imaging excised tumor specimens. While further investigations are needed to determine and test the spectral, spatial, and CT features required to classify tissue, this study demonstrates the ability of multimodal CT/SLI to quantify, visualize, and spatially navigate breast tumor specimens, which could potentially aid in the assessment of tumor margin status during BCS.
The Administrator's Use of Microcomputer Systems.
ERIC Educational Resources Information Center
Brown, Kenneth C.
1983-01-01
The use of microcomputers by college administrators to increase productivity is discussed. Microcomputers can help increase productivity in the following administrative office tasks: decision support, communication, personal assistance, and task management. One of the most promising developments to emerge from the decision sciences over the past…
Using the Microcomputer to Develop Listening Skills.
ERIC Educational Resources Information Center
Mohler, Stephen C.
A college-level introductory Spanish instructional system uses an interactive combination of microcomputer and program-stop tape recorder to enhance students' listening skills. The basic content is listening drills, adapted to the computer medium. Microcomputer use adds considerable versatility to instructional materials, including such features…
Increasing Productivity with Microcomputers: Key to Improvement of Special Educattion in the 1980s.
ERIC Educational Resources Information Center
Brady, Richard C.; Dodge, Bernard J.
1982-01-01
Five microcomputer applications which may improve the management of teacher education programs are noted (database management, word processing, spread sheets, project scheduling and management, and test scoring), and six steps in introducing microcomputers into a department are discussed. (CL)