Krishnaswamy, Venkataramanan; Hoopes, P. Jack; Samkoe, Kimberley S.; O'Hara, Julia A.; Hasan, Tayyaba; Pogue, Brian W.
2010-01-01
Highly localized reflectance measurements can be used to directly quantify scatter changes in tissues. This study presents a microsampling approach that is used to raster scan tumors to extract parameters believed to be related to the tissue ultra-structure. A confocal reflectance imager was developed to examine scatter changes across pathologically distinct regions within tumor tissues. Tissue sections from two murine tumors, AsPC-1 pancreas tumor and the Mat-LyLu Dunning prostate tumor, were imaged. After imaging, histopathology-guided region-of-interest studies of the images allowed analysis of the variations in scattering resulting from differences in tissue ultra-structure. On average, the median scatter power of tumor cells with high proliferation index was about 26% less compared to tumor cells with low proliferation index (LPI). Necrosis exhibited the lowest scatter power signature across all the tissue types considered, with about 55% lower median scatter power than LPI tumor cells. Additionally, the level and maturity of the tumor's fibroplastic response was found to influence the scatter signal. This approach to scatter visualization of tissue ultra-structure in situ could provide a unique tool for guiding surgical resection, but this kind of interpretation into what the signal means relative to the pathology is required before proceeding to clinical studies. PMID:19256692
NASA Astrophysics Data System (ADS)
Košařová, Veronika; Hradil, David; Hradilová, Janka; Čermáková, Zdeňka; Němec, Ivan; Schreiner, Manfred
2016-03-01
Twenty one mock-up samples containing inorganic pigments primarily used at the turn of the 19th and 20th century were selected for comparative study and measured by micro-Raman and portable Raman spectrometers. They included pure grounds (chalk-based, earth-based and lithopone-based), grounds covered by resin-based varnish, and different paint layers containing mixtures of white, yellow, orange, red, green, blue and black pigments, usually in combination with white pigments (titanium, zinc and barium whites or chalk). In addition, ten micro-samples obtained from seven paintings of two world-famous modern painters Edvard Munch and František Kupka have been investigated. Infrared reflection spectroscopy (FTIR), portable X-ray fluorescence (XRF) and scanning electron microscopy with energy dispersive spectroscopy (SEM-EDS) were used as supplementary methods. The measurements showed that blue pigments (ultramarine, Prussian blue and azurite), vermilion and ivory black in mixture with whites provided characteristic Raman spectra, while Co-, Cd- and Cr- pigments' bands were suppressed by fluorescence. The best success rate of micro-Raman spectroscopy has been achieved using the 780 nm excitation, however, the sensitivity of this excitation laser in a portable Raman instrument significantly decreased. The analyses of micro-samples of paintings by E. Munch and F. Kupka showed that micro-Raman spectroscopy identified pigments which would remain unidentified if analyzed only by SEM-EDS (zinc yellow, Prussian blue). On the other hand, chromium oxide green and ultramarine were not detected together in a sample due to overlap of their main bands. In those cases, it is always necessary to complement Raman analysis with other analytical methods.
Noh, Jermim; Suh, Yung Doug; Park, Yong Ki; Jin, Seung Min; Kim, Soo Ho; Woo, Seong Ihl
2007-07-01
Combined micro-Raman/UV-visible (vis)/fluorescence spectroscopy system, which can evaluate an integrated array of more than 10,000 microsamples with a minimuma size of 5 microm within a few hours, has been developed for the first time. The array of microsamples is positioned on a computer-controlled XY translation microstage with a spatial resolution of 1 mum so that the spectra can be mapped with micron precision. Micro-Raman spectrometers have a high spectral resolution of about 2 cm(-1) over the wave number range of 150-3900 cm(-1), while UV-vis and fluorescence spectrometers have high spectral resolutions of 0.4 and 0.1 nm over the wavelength range of 190-900 nm, respectively. In particular, the signal-to-noise ratio of the micro-Raman spectroscopy has been improved by using a holographic Raman grating and a liquid-nitrogen-cooled charge-coupled device detector. The performance of the combined spectroscopy system has been demonstrated by the high-throughput screening of a combinatorial ferroelectric (i.e., BaTi(x)Zr(1-x)O(3)) library. This system makes possible the structure analysis of various materials including ferroelectrics, catalysts, phosphors, polymers, alloys, and so on for the development of novel materials and the ultrasensitive detection of trace amounts of pharmaceuticals and diagnostic agents.
Dorofaeff, Tavey; Bandini, Rossella M; Lipman, Jeffrey; Ballot, Daynia E; Roberts, Jason A; Parker, Suzanne L
2016-09-01
With a decreasing supply of antibiotics that are effective against the pathogens that cause sepsis, it is critical that we learn to use currently available antibiotics optimally. Pharmacokinetic studies provide an evidence base from which we can optimize antibiotic dosing. However, these studies are challenging in critically ill neonate and pediatric patients due to the small blood volumes and associated risks and burden to the patient from taking blood. We investigate whether microsampling, that is, obtaining a biologic sample of low volume (<50 μL), can improve opportunities to conduct pharmacokinetic studies. We performed a literature search to find relevant articles using the following search terms: sepsis, critically ill, severe infection, intensive care AND antibiotic, pharmacokinetic, p(a)ediatric, neonate. For microsampling, we performed a search using antibiotics AND dried blood spots OR dried plasma spots OR volumetric absorptive microsampling OR solid-phase microextraction OR capillary microsampling OR microsampling. Databases searched include Web of Knowledge, PubMed, and EMbase. Of the 32 antibiotic pharmacokinetic studies performed on critically ill neonate or pediatric patients in this review, most of the authors identified changes to the pharmacokinetic properties in their patient group and recommended either further investigations into this patient population or therapeutic drug monitoring to ensure antibiotic doses are suitable. There remain considerable gaps in knowledge regarding the pharmacokinetic properties of antibiotics in critically ill pediatric patients. Implementing microsampling in an antibiotic pharmacokinetic study is contingent on the properties of the antibiotic, the pathophysiology of the patient (and how this can affect the microsample), and the location of the patient. A validation of the sampling technique is required before implementation. Current antibiotic regimens for critically ill neonate and pediatric patients are frequently suboptimal due to a poor understanding of altered pharmacokinetic properties. An assessment of the suitability of microsampling for pharmacokinetic studies in neonate and pediatric patients is recommended before wider use. The method of sampling, as well as the method of bioanalysis, also requires validation to ensure the data obtained reflect the true result. Copyright © 2016 Elsevier HS Journals, Inc. All rights reserved.
Fluorescence Lifetime Imaging and Spectroscopy as Tools for Nondestructive Analysis of Works of Art
NASA Astrophysics Data System (ADS)
Comelli, Daniela; D'Andrea, Cosimo; Valentini, Gianluca; Cubeddu, Rinaldo; Colombo, Chiara; Toniolo, Lucia
2004-04-01
A system for advanced fluorescence investigation of works of art has been assembled and integrated in a characterization procedure that allows one to localize and identify organic compounds that are present in artworks. At the beginning of the investigation, fluorescence lifetime imaging and spectroscopy address a selective microsampling of the artwork. Then analytical measurements of microsamples identify the chemical composition of the materials under investigation. Finally, on the basis of fluorescence lifetime and amplitude maps, analytical data are extended to the whole artwork. In such a way, information on the spatial distribution of organic materials can be inferred. These concepts have been successfully applied in an extensive campaign for analysis of Renaissance fresco paintings in Castiglione Olona, Italy. Residue of various types of glue and stucco left from a restoration carried out in the early 1970s was localized and classified. Insight into the technique used by the painter to make gilded reliefs was also obtained.
Guerra Valero, Yarmarly C; Wallis, Steven C; Lipman, Jeffrey; Stove, Christophe; Roberts, Jason A; Parker, Suzanne L
2018-03-01
Conventional sampling techniques for clinical pharmacokinetic studies often require the removal of large blood volumes from patients. This can result in a physiological or emotional burden, particularly for neonates or pediatric patients. Antibiotic pharmacokinetic studies are typically performed on healthy adults or general ward patients. These may not account for alterations to a patient's pathophysiology and can lead to suboptimal treatment. Microsampling offers an important opportunity for clinical pharmacokinetic studies in vulnerable patient populations, where smaller sample volumes can be collected. This systematic review provides a description of currently available microsampling techniques and an overview of studies reporting the quantitation and validation of antibiotics using microsampling. A comparison of microsampling to conventional sampling in clinical studies is included.
Fluorescence lifetime imaging and Fourier transform infrared spectroscopy of Michelangelo's David.
Comelli, Daniela; Valentini, Gianluca; Cubeddu, Rinaldo; Toniolo, Lucia
2005-09-01
We developed a combined procedure for the analysis of works of art based on a portable system for fluorescence imaging integrated with analytical measurements on microsamples. The method allows us to localize and identify organic and inorganic compounds present on the surface of artworks. The fluorescence apparatus measures the temporal and spectral features of the fluorescence emission, excited by ultraviolet (UV) laser pulses. The kinetic of the emission is studied through a fluorescence lifetime imaging system, while an optical multichannel analyzer measures the fluorescence spectra of selected points. The chemical characterization of the compounds present on the artistic surfaces is then performed by means of analytical measurements on microsamples collected with the assistance of the fluorescence maps. The previous concepts have been successfully applied to study the contaminants on the surface of Michelangelo's David. The fluorescence analysis combined with Fourier transform infrared (FT-IR) measurements revealed the presence of beeswax, which permeates most of the statue surface, and calcium oxalate deposits mainly arranged in vertical patterns and related to rain washing.
Assessing human weaning practices with calcium isotopes in tooth enamel
Tacail, Théo; Thivichon-Prince, Béatrice; Martin, Jeremy E.; Charles, Cyril; Viriot, Laurent
2017-01-01
Weaning practices differ among great apes and likely diverged during the course of human evolution, but behavioral inference from the fossil record is hampered by a lack of unambiguous biomarkers. Here, we show that early-life dietary transitions are recorded in human deciduous tooth enamel as marked variations in Ca isotope ratios (δ44/42Ca). Using a sequential microsampling method along the enamel growth axis, we collected more than 150 enamel microsamples from 51 deciduous teeth of 12 different modern human individuals of known dietary histories, as well as nine enamel samples from permanent third molars. We measured and reconstructed the evolution of 44Ca/42Ca ratios in enamel from in utero development to first months of postnatal development. We show that the observed variations of δ44/42Ca record a transition from placental nutrition to an adult-like diet and that Ca isotopes reflect the duration of the breastfeeding period experienced by each infant. Typically, the δ44/42Ca values of individuals briefly or not breastfed show a systematic increase during the first 5–10 mo, whereas individuals with long breastfeeding histories display no measurable variation in δ44/42Ca of enamel formed during this time. The use of Ca isotope analysis in tooth enamel allows microsampling and offers an independent approach to tackle challenging questions related to past population dynamics and evolution of weaning practices in hominins. PMID:28559355
Adhesive blood microsampling systems for steroid measurement via LC-MS/MS in the rat.
Heussner, Kirsten; Rauh, Manfred; Cordasic, Nada; Menendez-Castro, Carlos; Huebner, Hanna; Ruebner, Matthias; Schmidt, Marius; Hartner, Andrea; Rascher, Wolfgang; Fahlbusch, Fabian B
2017-04-01
Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS) allows for the direct analysis of multiple hormones in a single probe with minimal sample volume. Rodent-based animal studies strongly rely on microsampling, such as the dry blood spot (DBS) method. However, DBS suffers the drawback of hematocrit-dependence (non-volumetric). Hence, novel volumetric microsampling techniques were introduced recently, allowing sampling of fixed accurate volumes. We compared these methods for steroid analysis in the rat to improve inter-system comparability. We analyzed steroid levels in blood using the absorptive microsampling devices Whatman® 903 Protein Saver Cards, Noviplex™ Plasma Prep Cards and the Mitra™ Microsampling device and compared the obtained results to the respective EDTA plasma levels. Quantitative steroid analysis was performed via LC-MS/MS. For the determination of the plasma volume factor for each steroid, their levels in pooled blood samples from each human adults and rats (18weeks) were compared and the transferability of these factors was evaluated in a new set of juvenile (21days) and adult (18weeks) rats. Hematocrit was determined concomitantly. Using these approaches, we were unable to apply one single volume factor for each steroid. Instead, plasma volume factors had to be adjusted for the recovery rate of each steroid and device individually. The tested microsampling systems did not allow the use of one single volume factor for adult and juvenile rats based on an unexpectedly strong hematocrit-dependency and other steroid specific (pre-analytic) factors. Our study provides correction factors for LC-MS/MS steroid analysis of volumetric and non-volumetric microsampling systems in comparison to plasma. It argues for thorough analysis of chromatographic effects before the use of novel volumetric systems for steroid analysis. Copyright © 2017 Elsevier Inc. All rights reserved.
Boulyga, Sergei F; Prohaska, Thomas
2008-01-01
This paper presents the application of a multicollector inductively coupled plasma mass spectrometer (MC-ICP-MS)--a Nu Plasma HR--equipped with three ion-counting multipliers and coupled to a laser ablation system (LA) for the rapid and sensitive determination of the 235U/238U, 236U/238U, 145Nd/143Nd, 146Nd/143Nd, 101Ru/(99Ru+99Tc) and 102Ru/(99Ru+99Tc) isotope ratios in microsamples collected in the vicinity of Chernobyl. Microsamples with dimensions ranging from a hundred mum to about 1 mm and with surface alpha activities of 3-38 mBq were first identified using nuclear track radiography. U, Nd and Ru isotope systems were then measured sequentially for the same microsample by LA-MC-ICP-MS. The application of a zoom ion optic for aligning the ion beams into the ion counters allows fast switching between different isotope systems, which enables all of the abovementioned isotope ratios to be measured for the same microsample within a total analysis time of 15-20 min (excluding MC-ICP-MS optimization and calibration). The 101Ru/(99Ru+99Tc) and 102Ru/(99Ru+99Tc) isotope ratios were measured for four microsamples and were found to be significantly lower than the natural ratios, indicating that the microsamples were contaminated with the corresponding fission products (Ru and Tc). A slight depletion in 146Nd of about 3-5% was observed in the contaminated samples, but the Nd isotopic ratios measured in the contaminated samples coincided with natural isotopic composition within the measurement uncertainty, as most of the Nd in the analyzed samples originates from the natural soil load of this element. The 235U/238U and 236U/238U isotope ratios were the most sensitive indicators of irradiated uranium. The present work yielded a significant variation in uranium isotope ratios in microsamples, in contrast with previously published results from the bulk analysis of contaminated samples originating from the vicinity of Chernobyl. Thus, the 235U/238U ratios measured in ten microsamples varied in the range from 0.0073 (corresponding to the natural uranium isotopic composition) to 0.023 (corresponding to initial 235U enrichment in reactor fuel). An inverse correlation was observed between the 236U/238U and 235U/238U isotope ratios, except in the case of one sample with natural uranium. The heterogeneity of the uranium isotope composition is attributed to the different burn-up grades of uranium in the fuel rods from which the microsamples originated.
Baig, Jameel Ahmed; Kazi, Tasneem Gul; Elci, Latif; Afridi, Hassan Imran; Khan, Muhammad Irfan; Naseer, Hafiz Muhammad
2013-01-01
Simple and robust analytical procedures were developed for hexavalent chromium (Cr(VI)) and lead (Pb(II)) by dispersive liquid-liquid microextraction (DLLME) using microsample injection system coupled with flame atomic absorption spectrophotometry (MIS-FAAS). For the current study, ammonium pyrrolidine dithiocarbamate (APDC), carbon tetrachloride, and ethanol were used as chelating agent, extraction solvent, and disperser solvent, respectively. The effective variables of developed method have been optimized and studied in detail. The limit of detection of Cr(VI) and Pb(II) were 0.037 and 0.054 µg/L, respectively. The enrichment factors in both cases were 400 with 40 mL of initial volumes. The relative standard deviations (RSDs, n = 6) were <4%. The applicability and the accuracy of DLLME were estimated by the analysis of Cr(VI) and Pb(II) in industrial effluent wastewater by standard addition method (recoveries >96%). The proposed method was successfully applied to the determination of Cr(VI) and Pb(II) at ultratrace levels in natural drinking water and industrial effluents wastewater of Denizli. Moreover, the proposed method was compared with the literature reported method. PMID:24163779
Automated DBS microsampling, microscale automation and microflow LC-MS for therapeutic protein PK.
Zhang, Qian; Tomazela, Daniela; Vasicek, Lisa A; Spellman, Daniel S; Beaumont, Maribel; Shyong, BaoJen; Kenny, Jacqueline; Fauty, Scott; Fillgrove, Kerry; Harrelson, Jane; Bateman, Kevin P
2016-04-01
Reduce animal usage for discovery-stage PK studies for biologics programs using microsampling-based approaches and microscale LC-MS. We report the development of an automated DBS-based serial microsampling approach for studying the PK of therapeutic proteins in mice. Automated sample preparation and microflow LC-MS were used to enable assay miniaturization and improve overall assay throughput. Serial sampling of mice was possible over the full 21-day study period with the first six time points over 24 h being collected using automated DBS sample collection. Overall, this approach demonstrated comparable data to a previous study using single mice per time point liquid samples while reducing animal and compound requirements by 14-fold. Reduction in animals and drug material is enabled by the use of automated serial DBS microsampling for mice studies in discovery-stage studies of protein therapeutics.
Microsample analyses via DBS: challenges and opportunities.
Henion, Jack; Oliveira, Regina V; Chace, Donald H
2013-10-01
The use of DBS is an appealing approach to employing microsampling techniques for the bioanalysis of samples, as has been demonstrated for the past 50 years in the metabolic screening of metabolites and diseases. In addition to its minimally invasive sample collection procedures and its economical merits, DBS microsampling benefits from the very high sensitivity, selectivity and multianalyte capabilities of LC-MS, which has been especially well demonstrated in newborn screening applications. Only a few microliters of a biological fluid are required for analysis, which also translates to significantly reduced demands on clinical samples from patients or from animals. Recently, the pharmaceutical industry and other arenas have begun to explore the utility and practicality of DBS microsampling. This review discusses the basis for why DBS techniques are likely to be part of the future, as well as offering insights into where these benefits may be realized.
A nonlethal microsampling technique to monitor the effects of mercury on wild bird eggs
Stebbins, Katherine R.; Klimstra, Jon D.; ,; Ackerman, Joshua T.; Heinz, Gary
2009-01-01
Methylmercury is the predominant chemical form of mercury reported in the eggs of wild birds, and the embryo is the most sensitive life stage to methylmercury toxicity. Protective guidelines have been based mainly on captive-breeding studies with chickens (Gallus gallus), mallards (Anas platyrhynchos), and ring-necked pheasants (Phasianus colchicus) or on field studies where whole eggs were collected and analyzed and the effects of the mercury were measured based on the reproductive success of the remaining eggs. However, both of these methods have limitations. As an alternative, we developed a technique that involves extracting a small sample of albumen from a live egg, sealing the egg, returning the egg to its nest to be naturally incubated by the parents, and then relating the hatching success of this microsampled egg to its mercury concentration. After first developing this technique in the laboratory using chicken and mallard eggs, we selected the laughing gull (Larus atricilla) and black-necked stilt (Himantopus mexicanus) as test subjects in the field. We found that 92% of the microsampled laughing gull eggs met our reproductive endpoint of survival to the beginning of hatching compared to 100% for the paired control eggs within the same nests. Microsampled black-necked stilt eggs exhibited 100% hatching success compared to 93% for the paired control eggs. Our results indicate that microsampling is an effective tool for nonlethally sampling mercury concentrations in eggs and, as such, can be used for monitoring sensitive species, as well as for improving studies that examine the effects of mercury on avian reproduction.
NASA Astrophysics Data System (ADS)
Ovsyannikov, Sergey; Shchennikov, Vladimir
2004-03-01
In the present work the novel technique of investigation of thermomagnetic effects (longitudinal and transverse Nernst-Ettingshausen effects, Maggi-Righi-Leduc effects) on semiconductor micro-samples at high pressure up to 30 GPa has been developed. The technique has been applied for characterisation of semiconductor micro-samples and minerals of VI, IV-VI, and II-VI Groups. Advantages of thermomagnetic effects over the traditional galvanomagnetic ones have been demonstrated. It has been shown that technique of thermomagnetic measurements at high pressure is a powerful tool in studying of parameters of electron structure of semiconductors and being the perspective one for any technological applications. The work was supported by the Russian Foundation for Basic Research, Gr. No. 01-02-17203.
A spectroscopic study of Brazilwood paints in medieval books of hours.
Melo, Maria João; Otero, Vanessa; Vitorino, Tatiana; Araújo, Rita; Muralha, Vânia S F; Lemos, Ana; Picollo, Marcello
2014-01-01
In this work, microspectrofluorimetry was for the first time applied to the identification of the red organic lakes that are characteristic of the lavish illuminations found in 15(th) century books of hours. Microspectrofluorimetry identified those red paints, ranging from opaque pink to dark red glazes, as brazilwood lakes. An unequivocal characterization was achieved by comparison with reference paints produced following recipes from the medieval treatise The Book on How to Make Colours, and was further confirmed by fiber optic reflectance spectroscopy (FORS). For these treasured cultural objects, microspectrofluorimetry and FORS proved to be the only techniques that could identify, in situ or in microsamples, the chromophore responsible for the pinkish hues: a brazilein-Al(3+) complex. Additionally, a multi-analytical approach provided a full characterization of the color paints, including pigments, additives, and binders. Microspectroscopic techniques, based on infrared and X-ray radiation, enabled us to disclose the full palette of these medieval manuscripts, including the elusive greens, for which, besides malachite, basic copper sulfates were found; Raman microscopy suggested a mixture of brochantite and langite. Infrared analysis proved invaluable for a full characterization of the additives that were applied as fillers or whites (chalk, gypsum, and white lead) as well as the proteinaceous and polysaccharide binders that were found pure or in mixture.
Jackson-Addie, Kirsty; Woods, Karen; Muir, Allan; Smith, Christopher; Higton, David
2012-12-01
On behalf of the Drug Metabolism Discussion Group, Regulatory Bioanalysis AstraZeneca (UK) recently organized and hosted an extremely successful Drug Metabolism Discussion Group Short Meeting on 'microsampling--the next big thing'. This attracted over 140 delegates and a strong line up of presenters of respected scientists within the field. This meeting focused on the impact of taking a reduced sample (5-20 µl) from an animal, or later in the clinic, particularly neonates. The agenda covered the spectrum of microsampling, from capillary plasma microsampling, as championed by Ove Jonsson and Kristian Königsson, through to dried blood spots. The day was split up in to three sections, the morning concentrating on the sampling aspects from animals. A highlight of the first section was the 'poster blitz' where four poster presenters gave a quick overview of their work. This introduced the poster session and created a good atmosphere for general debate between the delegates. The mid-session saw the bioanalytical challenges discussed from the discovery to the preclinical stage. To encourage interaction between the presenters and the audience, a panel discussion was used that led to interesting insights into study design from toxicological and bioanalytical viewpoints. The final session was left to clinical aspects of microsampling and a particularly interesting presentation from Hitesh Pandya from the Pediatric Respiratory Medicine Department (University of Leicester, Leicester, UK). An eloquent and hard-hitting presentation put into perspective the importance of advancements in this field that enables sample to be taken in a noninvasive manner. The meeting was well received with excellent feedback from all concerned.
Di Turo, Francesca; Montoya, Noemí; Piquero-Cilla, Joan; De Vito, Caterina; Coletti, Fulvio; Favero, Gabriele; Doménech-Carbó, Antonio
2017-02-22
Voltammetry of microparticles (VMP) and electrochemical impedance spectroscopy (EIS) techniques, complemented by SEM-EDX and Raman spectroscopy, were applied to a set of 15 Roman bronze coins and one Tessera from the temple of Magna Mater (Rome, Italy). The archaeological site, dated back between the second half and the end of the 4th century A.D., presented a complicated stratigraphic context. Characteristic voltammetric patterns for cuprite and tenorite for sub-microsamples of the corrosion layers of the coins deposited onto graphite electrodes in contact with 0.10 M HClO 4 aqueous solution yielded a grouping of the coins into three main groups. This grouping was confirmed and refined using EIS experiments of the coins immersed in air-saturated mineral water using the reduction of dissolved oxygen as a redox probe. The electrochemical grouping of coins corroborated the complex stratigraphy of the archaeological site and, above all, the reuse of the coins during the later periods due to the economic issues related to the fall of the Roman Empire. Copyright © 2016 Elsevier B.V. All rights reserved.
Bronchoscopic assessment of airway retention time of aerosolized xylitol
Durairaj, Lakshmi; Neelakantan, Srividya; Launspach, Janice; Watt, Janet L; Allaman, Margaret M; Kearney, William R; Veng-Pedersen, Peter; Zabner, Joseph
2006-01-01
Background Human airway surface liquid (ASL) has abundant antimicrobial peptides whose potency increases as the salt concentration decreases. Xylitol is a 5-carbon sugar that has the ability to lower ASL salt concentration, potentially enhancing innate immunity. Xylitol was detected for 8 hours in the ASL after application in airway epithelium in vitro. We tested the airway retention time of aerosolized iso-osmotic xylitol in healthy volunteers. Methods After a screening spirometry, volunteers received 10 ml of nebulized 5% xylitol. Bronchoscopy was done at 20 minutes (n = 6), 90 minutes (n = 6), and 3 hours (n = 5) after nebulization and ASL was collected using microsampling probes, followed by bronchoalveolar lavage (BAL). Xylitol concentration was measured by nuclear magnetic resonance spectroscopy and corrected for dilution using urea concentration. Results All subjects tolerated nebulization and bronchoscopy well. Mean ASL volume recovered from the probes was 49 ± 23 μl. The mean ASL xylitol concentration at 20, 90, and 180 minutes was 1.6 ± 1.9 μg/μl, 0.6 ± 0.6 μg/μl, and 0.1 ± 0.1 μg/μl, respectively. Corresponding BAL concentration corrected for dilution was consistently lower at all time points. The terminal half-life of aerosolized xylitol obtained by the probes was 45 minutes with a mean residence time of 65 minutes in ASL. Corresponding BAL values were 36 and 50 minutes, respectively. Conclusion After a single dose nebulization, xylitol was detected in ASL for 3 hours, which was shorter than our in vitro measurement. The microsampling probe performed superior to BAL when sampling bronchial ASL. PMID:16483382
Klimstra, J.D.; Stebbins, K.R.; Heinz, G.H.
2007-01-01
Methylmercury is the predominant chemical form of mercury reported in the eggs of wild birds. The embryo is the life stage at which birds are most sensitive to methylmercury. Protective guidelines have been based largely on captive-breeding studies done with chickens (Gallus domesticus), mallards (Anas platyrhynchos), and ring-necked pheasants (Phasianus colchicus). Typically these studies are cost and time prohibitive. In the past, researchers have used either egg injections or the ?sample egg? technique to determine contaminant effects on bird eggs. Both techniques have their limitations. As an alternative to the above methods and because most of the methylmercury is found in the albumen we have developed a novel, less invasive technique, to micro-sample the albumen of eggs in the field. An albumen sample would be analyzed and then compared to the hatching success of that egg. Using the micro-sampling procedure, the egg is oriented with the blunt end up and the pointed end down. A vent hole is drilled at the top to relieve pressure. Approximately one third up from the bottom, a withdrawal site is drilled just until the inner shell membrane is exposed. A syringe with a 21 or 18 gauge needle is gently inserted just into the egg and approximately 200?300?l of albumen is removed. Almost concurrently this site and then the vent are sealed. Thus far we have experimented with both chicken and mallard eggs in the laboratory. We sampled chicken eggs at days 0 and 3 of incubation with a hatching success of 76% and 70%, respectively. Neither group was significantly different from control eggs (P=0.52, 0.54). Field studies are in progress using this technique in which birds are allowed to incubate their own eggs. We envision micro-sampling to be a tool that researchers and managers could use in the field to determine the effects of mercury or other contaminants in bird populations. Micro-sampling would reduce the impact on the sampled population and could be used to monitor sensitive species without impacting reproduction and recruitment.
A cryogenic tensile testing apparatus for micro-samples cooled by miniature pulse tube cryocooler
NASA Astrophysics Data System (ADS)
Chen, L. B.; Liu, S. X.; Gu, K. X.; Zhou, Y.; Wang, J. J.
2015-12-01
This paper introduces a cryogenic tensile testing apparatus for micro-samples cooled by a miniature pulse tube cryocooler. At present, tensile tests are widely applied to measure the mechanical properties of materials; most of the cryogenic tensile testing apparatus are designed for samples with standard sizes, while for non-standard size samples, especially for microsamples, the tensile testing cannot be conducted. The general approach to cool down the specimens for tensile testing is by using of liquid nitrogen or liquid helium, which is not convenient: it is difficult to keep the temperature of the specimens at an arbitrary set point precisely, besides, in some occasions, liquid nitrogen, especially liquid helium, is not easily available. To overcome these limitations, a cryogenic tensile testing apparatus cooled by a high frequency pulse tube cryocooler has been designed, built and tested. The operating temperatures of the developed tensile testing apparatus cover from 20 K to room temperature with a controlling precision of ±10 mK. The apparatus configurations, the methods of operation and some cooling performance will be described in this paper.
NASA Astrophysics Data System (ADS)
Koglin, E.
A new method for preparing SERS active surfaces using silver colloidal spheres deposited on HPTLC plates, used for thin-layer chromatography, is discussed in detail. The sensitivity of these activated HPTLC plates is so high that in-situ vibrational investigations of chromatogram spots are possible at the nanogram level. The HPTLC/SERS spectra of purine, benzoic acid and 1-nitro-pyrene adsorbed on silver colloidal activated silica gel plates are measured in the nanogram region. In addition we also report in this paper on the results of a feasibility study performed to evaluate the analytical potential of micro-Raman spectroscopy (triple monochromator, multichannel detection system) in SERS/HPTLC spot characterization. It permits the acquisition of Raman spectra from HPTLC spots down to 1 μm in size or other forms of microsamples approaching the picogram level in mass.
A Microsample Tensile Test Application: Local Strength of Impact Welds Between Sheet Metals
NASA Astrophysics Data System (ADS)
Benzing, J. T.; He, M.; Vivek, A.; Taber, G. A.; Mills, M. J.; Daehn, G. S.
2017-03-01
Microsample tensile testing was conducted to evaluate the quality of impact welds created by vaporizing foil actuator welding. Tensile test samples with a gauge length of 0.6 mm were electro-discharge machined out of welds created between 1-mm-thick aluminum alloy type 6061 (AA6061) sheets and 6-mm-thick copper (Cu110) plates. Aluminum sheets were used as flyers, while copper plates acted as targets. Flyer sheets in T6 as well as T4 temper conditions were utilized to create welds. Some of the welds made with T4 temper flyers were heat treated to a T6 temper. It was found that the welds made with T4 temper flyers were slightly stronger (max. of 270 MPa) than those produced with T6 temper flyers. Generally, failure propagated in a brittle manner across the weld interface; however, elemental mapping reveals material transfer on either member of the welded system. This work proves the feasibility to apply microsample tensile testing to assess impact welding, even when conducted with flyer sheets of 1 mm or less, and provides insight that is complementary to other test methods.
Gómez-Nieto, Beatriz; Gismera, Mª Jesús; Sevilla, Mª Teresa; Satrústegui, Jorgina; Procopio, Jesús R
2017-08-01
A micro-sampling and straightforward method based on high resolution continuum source atomic absorption spectrometry (HR-CS AAS) was developed to determine extracellular and intracellular Ca in samples of interest in clinical and biomedical analysis. Solid sampling platforms were used to introduce the micro-samples into the graphite furnace atomizer. The secondary absorption line for Ca, located at 239.856nm, was selected to carry out the measurements. Experimental parameters such as pyrolysis and atomization temperatures and the amount of sample introduced for the measurements were optimized. Calibration was performed using aqueous standards and the approach to measure at the wings of the absorption lines was employed for the expansion of the linear response range. The limit of detection was of 0.02mgL -1 Ca (0.39ng Ca) and the upper limit of linear range was increased up to 8.0mgL -1 Ca (160ng Ca). The proposed method was used to determine Ca in mitochondrial suspensions and whole blood samples with successful results. Adequate recoveries (within 91-107%) were obtained in the tests performed for validation purposes. Copyright © 2017 Elsevier B.V. All rights reserved.
Substrate-Mediated Laser Ablation under Ambient Conditions for Spatially-Resolved Tissue Proteomics
Fatou, Benoit; Wisztorski, Maxence; Focsa, Cristian; Salzet, Michel; Ziskind, Michael; Fournier, Isabelle
2015-01-01
Numerous applications of ambient Mass Spectrometry (MS) have been demonstrated over the past decade. They promoted the emergence of various micro-sampling techniques such as Laser Ablation/Droplet Capture (LADC). LADC consists in the ablation of analytes from a surface and their subsequent capture in a solvent droplet which can then be analyzed by MS. LADC is thus generally performed in the UV or IR range, using a wavelength at which analytes or the matrix absorb. In this work, we explore the potential of visible range LADC (532 nm) as a micro-sampling technology for large-scale proteomics analyses. We demonstrate that biomolecule analyses using 532 nm LADC are possible, despite the low absorbance of biomolecules at this wavelength. This is due to the preponderance of an indirect substrate-mediated ablation mechanism at low laser energy which contrasts with the conventional direct ablation driven by sample absorption. Using our custom LADC system and taking advantage of this substrate-mediated ablation mechanism, we were able to perform large-scale proteomic analyses of micro-sampled tissue sections and demonstrated the possible identification of proteins with relevant biological functions. Consequently, the 532 nm LADC technique offers a new tool for biological and clinical applications. PMID:26674367
Chemical conditions inside occluded regions on corroding aircraft aluminum alloys.
Lewis, K S; Yuan, J; Kelly, R G
1999-07-30
Corrosion of aluminum alloy structures costs the US Air Force in the order of US$1 x 10(9) annually. Corrosion develops in areas of overlap such as aircraft lap-splice joints and under protective organic coatings. Capillary electrophoresis (CE) has been used to determine the local chemistries at these corrosion sites of solutions that were extracted using a microsampling system. Analysis of the local solution within lap-splice joints from aircraft has been performed in two ways: rehydration of corrosion products and direct microsampling. The solutions collected were analyzed with CE to quantitatively determine the species present during corrosion. The most common ions detected were Cl-, NO2-, NO3-, HCO3-, K+, Al3+, Ca2+, Na+ and Mg2+. Studies of the solution chemistry under local coating defects are required to understand coating failure and develop more durable coatings. A microsampling system and micro pH sensor were developed to extract solution from and measure pH in defects with diameters as small as 170 microns. Actively corroding defects contained high concentrations of Cl-, Al3+, Mg2+, Mn2+ and Cu2+ whereas only trace levels of Mg2+ were found in repassivated defects. The effects of these species on initiation and propagation of corrosion are discussed.
Bleaching of red lake paints in encaustic mummy portraits
NASA Astrophysics Data System (ADS)
Miliani, Costanza; Daveri, Alessia; Spaabaek, Lin; Romani, Aldo; Manuali, Valentina; Sgamellotti, Antonio; Brunetti, Brunetto Giovanni
2010-09-01
The present paper reports on the study of the development of whitish opacity in pink paints in encaustic mummy portraits. Non-invasive measurements carried out on two encaustic portraits belonging to the Ny Carlsberg Glyptotek, Copenhagen, by reflectance FTIR and UV-vis fluorescence have shown that the areas prone to the bleaching phenomenon had been painted with melted beeswax and an anthraquinone vegetal lake mixed with calcium sulphate hemihydrate and dihydrate. The hypothesis that the bleaching disease was neither related to a degradation of the dyes nor to an alteration of the wax but rather to a dehydration-hydration reaction of the CaSO4-H2O system, has been corroborated by the analyses of two microsamples from the bleached areas and ascertained by accelerated ageing experiments on encaustic models.
NASA Astrophysics Data System (ADS)
Laughney, Ashley; Krishnaswamy, Venkat; Schwab, Mary; Wells, Wendy A.; Paulsen, Keith D.; Pogue, Brian W.
2009-02-01
The purpose of this study was to extract scatter parameters related to tissue ultra-structures from freshly excised breast tissue and to assess whether evident changes in scatter across diagnostic categories is primarily influenced by variation in the composition of each tissues subtypes or by physical remodeling of the extra-cellular environment. Pathologists easily distinguish between epithelium, stroma and adipose tissues, so this classification was adopted for macroscopic subtype classification. Micro-sampling reflectance spectroscopy was used to characterize single-backscattered photons from fresh, excised tumors and normal reduction specimens with sub-millimeter resolution. Phase contrast microscopy (sub-micron resolution) was used to characterize forward-scattered light through frozen tissue from the DHMC Tissue Bank, representing normal, benign and malignant breast tissue, sectioned at 10 microns. The packing density and orientation of collagen fibers in the extracellular matrix (ECM) associated with invasive, normal and benign epithelium was evaluated using transmission electron microscopy (TEM). Regions of interest (ROIs) in the H&E stained tissues were identified for analysis, as outlined by a pathologist as the gold standard. We conclude that the scatter parameters associated with tumor specimens (Npatients=6, Nspecimens=13) significantly differs from that of normal reductions (Npatients=6, Nspecimens=10). Further, tissue subtypes may be identified by their scatter spectra at sub-micron resolution. Stromal tissue scatters significantly more than the epithelial cells embedded in its ECM and adipose tissue scatters much less. However, the scatter signature of the stroma at the sub-micron level is not particularly differentiating in terms of a diagnosis.
The application of capillary microsampling in GLP toxicology studies.
Verhaeghe, Tom; Dillen, Lieve; Stieltjes, Hans; Zwart, Loeckie de; Feyen, Bianca; Diels, Luc; Vroman, Ann; Timmerman, Philip
2017-04-01
Capillary microsampling (CMS) to collect microplasma volumes is gradually replacing traditional, larger volume sampling from rats in GLP toxicology studies. About 32 µl of blood is collected with a capillary, processed to plasma and stored in a 10- or 4-µl capillary which is washed out further downstream in the laboratory. CMS has been standardized with respect to materials, assay validation experiments and application for sample analysis. The implementation of CMS has resulted in blood volume reductions in the rat from 300 to 32 µl per time point and the elimination of toxicokinetic satellite groups in the majority of the rat GLP toxicology studies. The technique has been successfully applied in 26 GLP studies for 12 different projects thus far.
NASA Astrophysics Data System (ADS)
Londero, Pablo
The characterization of artistic practice throughout history often requires measurements of material composition with microscopic resolution, either due to the fine detail of the material composition or to the amount of sample available. This problem is exacerbated for the detection of organic colorants, which are often embedded in a complex matrix (e.g. oil, natural fibers) and in low concentration due to their high tinting strength. Surface-Enhanced Raman Spectroscopy (SERS) is increasingly used in detection of organic colorants in cultural heritage due to its high sensitivity and inherent preferential sensitivity to small organic molecules. This talk will discuss recent results from a new SERS measurement technique, in which laser ablation is used as a micro-sampling method onto a SERS-active film to characterize art samples with microscopic precision and sensitivity comparable to many mass spectrometry measurements. Furthermore, the nature of the sampling method provides built-in benefits to other SERS-based techniques, such as more quantitative characterization of mixtures, improved sensitivity to some analytes, and reduced background interference. Examples will be shown for measurements of reference materials and art objects, including a restored 16th-century dish and a Renaissance fresco, The Incredulity of San Thomas, by Luca Signorelli. Supported by the National Science Foundation (NSF-CHE-1402750).
Frentiu, Tiberiu; Darvasi, Eugen; Butaciu, Sinziana; Ponta, Michaela; Petreus, Dorin; Mihaltan, Alin I; Frentiu, Maria
2014-11-01
A low power and low argon consumption (13.56 MHz, 15 W, 150 ml min(-1)) capacitively coupled plasma microtorch interfaced with a low-resolution microspectrometer and a small-sized electrothermal vaporization Rh coiled-filament as liquid microsample introduction device into the plasma was investigated for the simultaneous determination of several volatile elements of interest for environment. Constructive details, spectral and analytical characteristics, and optimum operating conditions of the laboratory equipment for the simultaneous determination of Ag, Cd, Cu, Pb and Zn requiring low vaporization power are provided. The method involves drying of 10 μl sample at 100°C, vaporization at 1500°C and emission measurement by capture of 20 successive spectral episodes each at an integration time of 500 ms. Experiments showed that emission of elements and plasma background were disturbed by the presence of complex matrix and hot Ar flow transporting the microsample into plasma. The emission spectrum of elements is simple, dominated by the resonance lines. The analytical system provided detection limits in the ng ml(-1) range: 0.5(Ag); 1.5(Cd); 5.6(Cu); 20(Pb) and 3(Zn) and absolute detection limits of the order of pg: 5(Ag); 15(Cd); 56(Cu); 200(Pb) and 30(Zn). It was demonstrated the utility and capability of the miniaturized analytical system in the simultaneous determination of elements in soil and water sediment using the standard addition method to compensate for the non-spectral effects of alkali and earth alkaline elements. The analysis of eight certified reference materials exhibited reliable results with recovery in the range of 95-108% and precision of 0.5-9.0% for the five examined elements. The proposed miniaturized analytical system is attractive due to the simple construction of the electrothermal vaporization device and microtorch, low costs associated to plasma generation, high analytical sensitivity and easy-to-run for simultaneous multielemental analysis of liquid microsamples. Copyright © 2014. Published by Elsevier B.V.
Lab and Pore-Scale Study of Low Permeable Soils Diffusional Tortuosity
NASA Astrophysics Data System (ADS)
Lekhov, V.; Pozdniakov, S. P.; Denisova, L.
2016-12-01
Diffusion plays important role in contaminant spreading in low permeable units. The effective diffusion coefficient of saturated porous medium depends on this coefficient in water, porosity and structural parameter of porous space - tortuosity. Theoretical models of relationship between porosity and diffusional tortuosity are usually derived for conceptual granular models of medium filled by solid particles of simple geometry. These models usually do not represent soils with complex microstructure. The empirical models, like as Archie's law, based on the experimental electrical conductivity data are mostly useful for practical applications. Such models contain empirical parameters that should be defined experimentally for given soil type. In this work, we compared tortuosity values obtained in lab-scale diffusional experiments and pore scale diffusion simulation for the studied soil microstructure and exanimated relationship between tortuosity and porosity. Samples for the study were taken from borehole cores of low-permeable silt-clay formation. Using the samples of 50 cm3 we performed lab scale diffusional experiments and estimated the lab-scale tortuosity. Next using these samples we studied the microstructure with X-ray microtomograph. Shooting performed on undisturbed microsamples of size 1,53 mm with a resolution ×300 (10243 vox). After binarization of each obtained 3-D structure, its spatial correlation analysis was performed. This analysis showed that the spatial correlation scale of the indicator variogram is considerably smaller than microsample length. Then there was the numerical simulation of the Laplace equation with binary coefficients for each microsamples. The total number of simulations at the finite-difference grid of 1753 cells was 3500. As a result the effective diffusion coefficient, tortuosity and porosity values were obtained for all studied microsamples. The results were analyzed in the form of graph of tortuosity versus porosity. The 6 experimental tortuosity values well agree with pore-scale simulations falling in the general pattern that shows nonlinear decreasing of tortuosity with decreasing of porosity. Fitting this graph by Archie model we found exponent value in the range between 1,8 and 2,4. This work was supported by RFBR via grant 14-05-00409.
Dried haematic microsamples and LC-MS/MS for the analysis of natural and synthetic cannabinoids.
Protti, Michele; Rudge, James; Sberna, Angelo Eliseo; Gerra, Gilberto; Mercolini, Laura
2017-02-15
Synthetic cannabinoids are new psychoactive substances (NPS) with similar effects when compared to natural ones found in Cannabis derivatives. They have rapidly integrated into the illicit market, often sold as alternatives under international control. The need to identify and quantify an unprecedented and growing number of new compounds represents a unique challenge for toxicological, forensic and anti-doping analysis. Dried blood spots have been used within the bioanalytical framework in place of plasma or serum, in order to reduce invasiveness, lower sample size, simplify handling, storage and shipping of samples and to facilitate home-based and on-field applications. However, DBS implementation has been limited mainly by concerns related to haematocrit effect on method accuracy. Volumetric absorptive microsampling (VAMS™), a second generation dried miniaturized sampling technology, has been developed just in order to eliminate haematocrit effect, thus providing accurate sampling but still granting feasible sample processing. An original LC-MS/MS method was herein developed and validated for the analysis of THC and its 2 main metabolites, together with 10 representative synthetic cannabinoids in both DBS and VAMS dried microsamples. The ultimate goal of this work is to provide highly innovative DBS and VAMS analytical protocols, whose performances were extensively optimized and compared, in order to provide effective and alternative tools that can be applied for natural and synthetic cannabinoid determination, in place of classical analytical strategies. Copyright © 2016 Elsevier B.V. All rights reserved.
Microsample Characterization of Coatings for Grcop-84 for High Heat Flux Applications
NASA Technical Reports Server (NTRS)
Hemker, Kevin
2003-01-01
A multidisciplinary Johns Hopkins University-NASA Glenn team is undertaking a collaborative research program to elucidate and model the thermal stability and mechanical integrity of candidate coatings for GRCop-84. GRCop-84 is a high conductivity, high strength copper alloy that was recently developed at NASA Glenn for use in high temperature, high heat flux applications. With potential applications in rocket motor combustion chamber liners, nozzle ramps and other actively cooled structures, this new material offers great potential for decreasing weight and increasing reliability of third generation reusable launch vehicles. Current emphasis has turned toward the development of environmentally resistant and thermal barrier coatings for this alloy. Metallic coatings such as NiCrAlY and Cu-8-30%Cr have shown promise in: prohibiting blanching, reducing dog-house failures, increasing operating temperatures and decreasing cooling requirements. The focus of this research program is to develop a fundamental understanding of the substrate-coating interactions that occur during thermal cycling (inter-diffusion, viscoplasticity, morphological evolution, crack formation, etc.) and to derive a science-based protocol for future coating selection, optimization and reliability assurance. The microsample tensile testing approach adopted for this study allows us to characterize small-scale and highly scale-specific coatings and properties in a way not possible by conventional means. In addition to providing much needed design data, the integration of microsample testing with detailed microstructural observations provides a mechanistic foundation for coating optimization and life prediction modeling.
Granzotto, Clara; Sutherland, Ken
2017-03-07
This paper reports an improved method for the identification of Acacia gum in cultural heritage samples using matrix assisted laser desorption ionization-time-of-flight mass spectrometry (MALDI-TOF MS) after enzymatic digestion of the polysaccharide component. The analytical strategy was optimized using a reference Acacia gum (gum arabic, sp. A. senegal) and provided an unambiguous MS profile of the gum, characterized by specific and recognized oligosaccharides, from as little as 0.1 μg of material. The enhanced experimental approach with reduced detection limit was successfully applied to the analysis of naturally aged (∼80 year) gum arabic samples, pure and mixed with lead white pigment, and allowed the detection of gum arabic in samples from a late painting (1949/1954) by Georges Braque in the collection of the Art Institute of Chicago. This first application of the technique to characterize microsamples from a painting, in conjunction with analyses by gas chromatography/mass spectrometry (GC/MS), provided important insights into Braque's unusual mixed paint media that are also helpful to inform appropriate conservation treatments for his works. The robustness of the analytical strategy due to the reproducibility of the gum MS profile, even in the presence of other organic and inorganic components, together with the minimal sample size required, demonstrate the value of this new MALDI-TOF MS method as an analytical tool for the identification of gum arabic in microsamples from museum artifacts.
Vogel, J; Normand, P; Thioulouse, J; Nesme, X; Grundmann, G L
2003-03-01
The spatial and genetic unit of bacterial population structure is the clone. Surprisingly, very little is known about the spread of a clone (spatial distance between clonally related bacteria) and the relationship between spatial distance and genetic distance, especially at very short scale (microhabitat scale), where cell division takes place. Agrobacterium spp. Biovar 1 was chosen because it is a soil bacterial taxon easy to isolate. A total of 865 microsamples 500 microm in diameter were sampled with spatial coordinates in 1 cm(3) of undisturbed soil. The 55 isolates obtained yielded 42 ribotypes, covering three genomic species based on amplified ribosomal DNA restriction analysis (ARDRA) of the intergenic spacer 16S-23S, seven of which contained two to six isolates. These clonemates (identical ARDRA patterns) could be found in the same microsample or 1 cm apart. The genetic diversity did not change with distance, indicating the same habitat variability across the cube. The mixing of ribotypes, as assessed by the spatial position of clonemates, corresponded to an overlapping of clones. Although the population probably was in a recession stage in the cube (10(3) agrobacteria g(-1)), a high genetic diversity was maintained. In two independent microsamples (500 microm in diameter) at the invasion stage, the average genetic diversity was at the same level as in the cube. Quantification of the microdiversity landscape will help to estimate the probability of encounter between bacteria under realistic natural conditions and to set appropriate sampling strategies for population genetic analysis.
Microscale characterization of metallic coatings for a high strength high conductivity copper alloy
NASA Astrophysics Data System (ADS)
Jain, Piyush
NiCrAlY overlay coatings are being considered by NASA's Glenn Research Center to prevent blanching and reduce thermo-mechanical fatigue of rocket engine combustion chamber liners made of GRCop-84 (Cu-8%Cr-4%Nb) for reusable launch vehicles (RLVs). However, their successful application depends upon their integrity to the GRCop-84 during multiple firings of rocket engines. This study focuses on determining the adhesion of NiCrAlY coatings and their microstructural stability on GRCop-84 as a function of thermal cycling. Specimens were prepared by depositing NiCrAlY top coat on GRCop-84 by vacuum plasma spaying with a thin layer of Cu-26Cr as a bond coat. A thermal cycling rig was built to thermally cycle the NiCrAlY/Cu-26Cr/GRCop-84 specimens from RT to 600°C in an argon environment, with 10 minutes hold at 600°C, and 4 minutes hold at RT. Samples were cut from the coupons in as-received condition (AR), after 100 thermal cycles (TC-100), and after 300 thermal cycles (TC-300) for characterization. A newly developed interfacial microsample testing technique was employed to determine the adhesion of the coatings on GRCop-84, where bowtie shaped microsamples having interfaces normal to the tensile axis were tested. Interfacial microsamples of NiCrAlY/Cu-26Cr/GRCop-84 in all the conditions (AR, TC-100, and TC-300) failed cohesively in the substrate at a UTS of 380+/-5 MPa and their interfaces remained intact. The microstructural characterization revealed that microstructure of the NiCrAlY/Cu-26Cr/GRCop-84 specimens does not degrade as a function of thermal cycling. Constitutive properties of NiCrAlY, Cu-26Cr, and GRCop-84 were measured by testing monolithic samples and were used to build the finite element model (FEM) of the interfacial microsamples. The FE model analyzed the local stress-strain in the interfacial microsamples during the testing and confirmed the strength of the interfaces to be higher than 380+/-5 MPa. Depleted zones, devoid of Cr2Nb particles, were observed in the substrate near the interface, which has been attributed to uncontrolled processing parameters during the coating deposition. The interfacial microsamples containing depleted zones, failed at 335+/-25 MPa in AR condition exhibiting cohesive-adhesive failure, and at 360+/-15 MPa in TC-300 condition exhibiting adhesive failure. All these results suggested that the presence of depleted zone decreases the adhesion of the coating and should be avoided in future coatings deposition. Adhesion of two top coats, NiCrAlY (with the Cu-26Cr bond coat) and the Cu-26Cr (without any bond coat), were found to be lower on the grit blasted GRCop-84 than on the polished GRCop-84. The adhesion of both the top coats on polished GRCop-84 was measured to be 380+/-5 MPa with cohesive failure in the substrate, while the adhesion of NiCrAlY top coat on the grit blasted GRCop-84 was measured to be 142+/-35 MPa with cohesive failure in the Cu-26Cr bond coat, and the adhesion of Cu-26Cr top coat on the grit blasted GRCop-84 was measured to be 360+/-25 MPa with cohesive failure in the Cu-26Cr top coat. The microstructural characterization revealed that the reason of lower strength of top coats on the grit blasted GRCop-84 was the porosity present in the coatings on the grit blasted GRCop-84, while the coatings on the polished GRCop-84 did not have any measurable porosity.
Reflectance Spectroscopy | Photovoltaic Research | NREL
Reflectance Spectroscopy Reflectance Spectroscopy In a fraction of a second, the photovoltaic (PV metallization properties. PV Research Other Measurements pages: Device Performance Analytical Microscopy & directly normal. The reflectance measurement uses a principle of reciprocity Schematic of the PV
Material for surface-enhanced Raman spectroscopy, and SER sensors and method for preparing same
NASA Technical Reports Server (NTRS)
Farquharson, Stuart (Inventor); Nelson, Chad (Inventor); Lee, Yuan-Hsiang (Inventor)
2003-01-01
Metal-doped sol-gel materials, suitable for use as sensors for surface-enhanced Raman spectroscopic analysis for trace chemical detection, are produced by effecting gelation and solvent removal of a doped sol-gel under mild temperature conditions. At least in certain instances reaction and drying will desirably be effected in an oxygen-starved environment. The metal of the sol-gel material functions, when irradiated, to produce a plasmon field for interaction with molecules of an analyte in contact therewith, increasing by orders of magnitude Raman photons that are generate by excitation radiation, and the method allows matching of the metal and metal particle size to a wavelength of light (or incident radiation, e.g., laser radiation) to generate surface plasmons. The porosity of the sol-gel material dramatically increases the surface area, and thereby the amount of metal exposed for analyte interaction. The sensors provided may be in the form of glass vials, fiber optics, multi-well micro-sample plates, etc., having surface coatings of the doped sol-gel material, to provide sampling systems for use in a Raman instrument.
NASA Astrophysics Data System (ADS)
Belushkin, A. V.; Manoshin, S. A.; Kozlenko, D. P.; Kichanov, S. E.
2018-06-01
Possible options for modernization of the neutron beam forming system of the DN-6 diffractometer for the study of crystal and magnetic structures of microsamples at high pressures are being considered. It was demonstrated that for samples with the cross-section not exceeding 5 × 5 mm2 the most efficient option would be the use of an elliptical neutron guide. It allows to deliver neutrons for large distances from the source to samples with minimal losses using, as a rule, just one neutron reflection per dimension i.e. one at a side and one at top or bottom. For the present moment due to technical difficulties of such option realization, the simplified solution was proposed. At the end of the curved neutron guide it is planned to install a vertical plane focusing 7-meter-long parabolic section. Such a modernization will increase the neutron flux at the sample by a factor 1.5-3.5 and reduce respectively the typical measurement times.
Growth history of cultured pearl oysters based on stable oxygen isotope analysis
NASA Astrophysics Data System (ADS)
Nakashima, R.; Furuta, N.; Suzuki, A.; Kawahata, H.; Shikazono, N.
2007-12-01
We investigated the oxygen isotopic ratio in shells of the pearl oyster Pinctada martensii cultivated in embayments in Mie Prefecture, central Japan, to evaluate the biomineralization of shell structures of the species and its pearls in response to environmental change. Microsamples for oxygen isotope analysis were collected from the surfaces of shells (outer, middle, and inner shell layers) and pearls. Water temperature variations were estimated from the oxygen isotope values of the carbonate. Oxygen isotope profiles of the prismatic calcite of the outer shell layer reflected seasonal variations of water temperature, whereas those of nacreous aragonites of the middle and inner shell layers and pearls recorded temperatures from April to November, June to September, and July to September, respectively. Lower temperatures in autumn and winter might slow the growth of nacreous aragonites. The oxygen isotope values are controlled by both variations of water temperature and shell structures; the prismatic calcite of this species is useful for reconstructing seasonal changes of calcification temperature.
NASA Astrophysics Data System (ADS)
Karagiannis, Georgios Th.
2016-04-01
The development of non-destructive techniques is a reality in the field of conservation science. These techniques are usually not so accurate, as the analytical micro-sampling techniques, however, the proper development of soft-computing techniques can improve their accuracy. In this work, we propose a real-time fast acquisition spectroscopic mapping imaging system that operates from the ultraviolet to mid infrared (UV/Vis/nIR/mIR) area of the electromagnetic spectrum and it is supported by a set of soft-computing methods to identify the materials that exist in a stratigraphic structure of paint layers. Particularly, the system acquires spectra in diffuse-reflectance mode, scanning in a Region-Of-Interest (ROI), and having wavelength range from 200 up to 5000 nm. Also, a fuzzy c-means clustering algorithm, i.e., the particular soft-computing algorithm, produces the mapping images. The evaluation of the method was tested on a byzantine painted icon.
Veneranda, Marco; Prieto-Taboada, Nagore; de Vallejuelo, Silvia Fdez-Ortiz; Maguregui, Maite; Morillas, Hector; Marcaida, Iker; Castro, Kepa; Madariaga, Juan Manuel; Osanna, Massimo
2017-08-01
This work was focused on the study of the biodegradation processes jeopardizing a mural painting conserved in the basement of Ariadne House (archaeological site of Pompeii, Italy). The fresco stood out for its peculiar state of preservation: the upper part, recovered in 1988, was just barely colonized by microorganisms. On the contrary, the lower part (excavated in 2005) was almost completely covered by extensive biological patinas. The genomic characterization carried out by polymerase chain reaction (PCR) highlighted the presence of seven different fungi strains on the mural surface. Beside, in situ and laboratory analyses were performed with the purpose of identifying the causes of the heterogeneous spatial distribution of the biopatinas. The in situ Raman spectroscopy and energy dispersive X-ray fluorescence (ED-XRF) spectroscopy measurements excluded any link between the heterogeneous colonization and the original materials present in the wall. On the other side, X-ray diffraction (XRD) and scanning electron microscopy (SEM) on microsamples proved the presence of a thin volcanic material layer overlying the lower part of the fresco. Considering that most of the biofilms of the studied mural painting only growth over these residues, it was confirmed the role of volcanic material as a suitable support for biological colonization. Thanks to the obtained results, this research helped to understand more in depth an important degradation pathway threatening the artworks from one of the most important archaeological sites in the world.
Guo, Canyong; Luo, Xuefang; Zhou, Xiaohua; Shi, Beijia; Wang, Juanjuan; Zhao, Jinqi; Zhang, Xiaoxia
2017-06-05
Vibrational spectroscopic techniques such as infrared, near-infrared and Raman spectroscopy have become popular in detecting and quantifying polymorphism of pharmaceutics since they are fast and non-destructive. This study assessed the ability of three vibrational spectroscopy combined with multivariate analysis to quantify a low-content undesired polymorph within a binary polymorphic mixture. Partial least squares (PLS) regression and support vector machine (SVM) regression were employed to build quantitative models. Fusidic acid, a steroidal antibiotic, was used as the model compound. It was found that PLS regression performed slightly better than SVM regression in all the three spectroscopic techniques. Root mean square errors of prediction (RMSEP) were ranging from 0.48% to 1.17% for diffuse reflectance FTIR spectroscopy and 1.60-1.93% for diffuse reflectance FT-NIR spectroscopy and 1.62-2.31% for Raman spectroscopy. The results indicate that diffuse reflectance FTIR spectroscopy offers significant advantages in providing accurate measurement of polymorphic content in the fusidic acid binary mixtures, while Raman spectroscopy is the least accurate technique for quantitative analysis of polymorphs. Copyright © 2017 Elsevier B.V. All rights reserved.
The perspectives, information and conclusions conveyed in research project abstracts, progress reports, final reports, journal abstracts and journal publications convey the viewpoints of the principal investigator and may not represent the views and policies of ORD and EPA. Concl...
Reflectance spectroscopy in planetary science: Review and strategy for the future
NASA Technical Reports Server (NTRS)
Mccord, Thomas B. (Editor)
1987-01-01
Reflectance spectroscopy is a remote sensing technique used to study the surfaces and atmospheres of solar system bodies. It provides first-order information on the presence and amounts of certain ions, molecules, and minerals on a surface or in an atmosphere. Reflectance spectroscopy has become one of the most important investigations conducted on most current and planned NASA Solar System Exploration Program space missions. This book reviews the field of reflectance spectroscopy, including information on the scientific technique, contributions, present conditions, and future directions and needs.
NASA Technical Reports Server (NTRS)
Jain, Piyush; Hemker, Kevin J.; Raj, Sai V.
2004-01-01
NASA's Glenn Research Center has developed GRCop-84 (Cu-8at.%Cr-4% Nb), a high conductivity, high strength copper alloy for use as liners in rocket engine combustion chambers, nozzle ramps and other actively-cooled components subject to high heat fluxes. Two metallic coatings, NiCrAlY and Cu-26%Cr, are being considered for preventing blanching, reducing 'dog- house' failures and providing better environmental resistance to the GRCop-84 liners. This presentation will outline a study of coating-substrate interactions that occur as a result of thermal cycling and coating specific properties at different temperatures. A furnace has been built to thermally cycle the samples under argon. The microsample testing approach is being used to measure the coating-substrate interfacial strength. Cu-26Cr/GRCop-84 samples did not show any obvious interdiffusion after 300 thermal cycles. Interfacial strength tests of these samples were affected by porosity present in the samples. A complete set of observations and results for Cu-26Cr and NiCrAlY coatings will be presented.
Watanabe, Kentaro; Nagata, Takahiro; Oh, Seungjun; Wakayama, Yutaka; Sekiguchi, Takashi; Volk, János; Nakamura, Yoshiaki
2016-01-01
Future one-dimensional electronics require single-crystalline semiconductor free-standing nanorods grown with uniform electrical properties. However, this is currently unrealistic as each crystallographic plane of a nanorod grows at unique incorporation rates of environmental dopants, which forms axial and lateral growth sectors with different carrier concentrations. Here we propose a series of techniques that micro-sample a free-standing nanorod of interest, fabricate its arbitrary cross-sections by controlling focused ion beam incidence orientation, and visualize its internal carrier concentration map. ZnO nanorods are grown by selective area homoepitaxy in precursor aqueous solution, each of which has a (0001):+c top-plane and six {1–100}:m side-planes. Near-band-edge cathodoluminescence nanospectroscopy evaluates carrier concentration map within a nanorod at high spatial resolution (60 nm) and high sensitivity. It also visualizes +c and m growth sectors at arbitrary nanorod cross-section and history of local transient growth events within each growth sector. Our technique paves the way for well-defined bottom-up nanoelectronics. PMID:26881966
Chen, Guang; Li, Jun; Sun, Zhiwei; Zhang, Shijuan; Li, Guoliang; Song, Cuihua; Suo, Yourui; You, Jinmao
2014-01-15
Amino acids, as the main contributors to taste, are usually found in relatively high levels in bitter foods. In this work, we focused on seeking a rapid, sensitive and simple method to determine FAA for large batches of micro-samples and to explore the relationship between FAA and bitterness. Overall condition optimisation indicated that the new UDME technique offered higher derivatisation yields and extraction efficiencies than traditional methods. Only 35min was needed in the whole operation process. Very low LLOQ (Lower limit of quantification: 0.21-5.43nmol/L) for FAA in twelve bitter foods was obtained, with which BTT (bitter taste thresholds) and CABT (content of FAA at BTT level) were newly determined. The ratio of CABT to BTT increased with decreasing of BTT. This work provided powerful potential for the high-throughput trace analysis of micro-sample and also a methodology to study the relationship between the chemical constituents and the taste. Copyright © 2013 Elsevier Ltd. All rights reserved.
Evaluating performance of stormwater sampling approaches using a dynamic watershed model.
Ackerman, Drew; Stein, Eric D; Ritter, Kerry J
2011-09-01
Accurate quantification of stormwater pollutant levels is essential for estimating overall contaminant discharge to receiving waters. Numerous sampling approaches exist that attempt to balance accuracy against the costs associated with the sampling method. This study employs a novel and practical approach of evaluating the accuracy of different stormwater monitoring methodologies using stormflows and constituent concentrations produced by a fully validated continuous simulation watershed model. A major advantage of using a watershed model to simulate pollutant concentrations is that a large number of storms representing a broad range of conditions can be applied in testing the various sampling approaches. Seventy-eight distinct methodologies were evaluated by "virtual samplings" of 166 simulated storms of varying size, intensity and duration, representing 14 years of storms in Ballona Creek near Los Angeles, California. The 78 methods can be grouped into four general strategies: volume-paced compositing, time-paced compositing, pollutograph sampling, and microsampling. The performances of each sampling strategy was evaluated by comparing the (1) median relative error between the virtually sampled and the true modeled event mean concentration (EMC) of each storm (accuracy), (2) median absolute deviation about the median or "MAD" of the relative error or (precision), and (3) the percentage of storms where sampling methods were within 10% of the true EMC (combined measures of accuracy and precision). Finally, costs associated with site setup, sampling, and laboratory analysis were estimated for each method. Pollutograph sampling consistently outperformed the other three methods both in terms of accuracy and precision, but was the most costly method evaluated. Time-paced sampling consistently underestimated while volume-paced sampling over estimated the storm EMCs. Microsampling performance approached that of pollutograph sampling at a substantial cost savings. The most efficient method for routine stormwater monitoring in terms of a balance between performance and cost was volume-paced microsampling, with variable sample pacing to ensure that the entirety of the storm was captured. Pollutograph sampling is recommended if the data are to be used for detailed analysis of runoff dynamics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Richter, L.J.; Buntin, S.A.; Chu, P.M.
1994-02-15
The adsorption and photodecomposition of Mo(CO)[sub 6] adsorbed on Si(111) 7[times]7 surfaces has been studied with Auger electron spectroscopy, temperature programmed desorption, low energy electron diffraction and infrared reflection absorption spectroscopy in a single external reflection configuration. The external-reflection technique is demonstrated to have adequate sensitivity to characterize submonolayer coverages of photogenerated Mo(CO)[sub [ital x
NASA Astrophysics Data System (ADS)
Genty-Vincent, Anaïs; Eveno, Myriam; Nowik, Witold; Bastian, Gilles; Ravaud, Elisabeth; Cabillic, Isabelle; Uziel, Jacques; Lubin-Germain, Nadège; Menu, Michel
2015-11-01
The blanching of easel paintings can affect the varnish layer and also the paint layer with a blurring effect. The understanding of the physicochemical and optical phenomena involved in the whitening process remains an important challenge for the painting conservation. A set of ca. 50 microsamples from French, Flemish, and Italian blanched oil paintings, from sixteenth to nineteenth century, have been collected for in deep investigations. In parallel, the reproduction of the alteration was achieved by preparing some paint layers according to historical treatises and altering them in a climatic chamber in a humid environment or directly by immersing in ultrapure water. The observation of raw samples with a field-emission gun scanning electron microscope revealed for the first time that the altered layers have an unexpected highly porous structure with a pore size ranging from ca. 40 nm to 2 μm. The formation mechanism of these pores should mostly be physical as the supplementary analyses (Fourier transform infrared spectroscopy, gas chromatography-mass spectrometry) do not reveal any noticeable molecular modification. Considering the tiny size of the pores, the alteration can be explained by the Rayleigh or Mie light scattering.
USDA-ARS?s Scientific Manuscript database
In previous study, we have reported the development of simple algorithms for determining fiber maturity and crystallinity from Fourier transform (FT) -mid-infrared (IR) measurement. Due to its micro-sampling feature, we were able to assess the fiber maturity and crystallinity at different portions o...
Diffuse reflectance spectroscopy of pre- and post-treated oral submucous fibrosis: an in vivo study
NASA Astrophysics Data System (ADS)
Sivabalan, S.; Ponranjini Vedeswari, C.; Jayachandran, S.; Koteeswaran, D.; Pravda, C.; Aruna, P.; Ganesan, S.
2010-02-01
Oral submucous fibrosis (OSF) is a high risk precancerous condition characterized by changes in the connective tissue fibers of the lamina propria and deeper parts leading to stiffness of the mucosa and restricted mouth opening, fibrosis of the lining mucosa of the upper digestive tract involving the oral cavity, oro- and hypo-pharynx and the upper two-thirds of the oesophagus. Optical reflectance measurements have been used to extract diagnostic information from a variety of tissue types, in vivo. We apply diffuse reflectance spectroscopy to quantitatively monitor tumour response to chemotherapy. Twenty patients with submucous fibrosis were diagnosed with diffuse reflectance spectroscopy and treated with the chemotherapy drug, Dexamethasone sodium phosphate and Hyaluronidase injection for seven weeks and after the treatment they were again subjected to the diffuse reflectance spectroscopy. The major observed spectral alterations on pre and post treated submucous fibrosis is an increase in the diffuse reflectance from 450 to 600 nm. Normal mucosa has showed higher reflectance when compared to the pre and post-treated cases. The spectral changes were quantified and correlated to conventional diagnostic results viz., maximum mouth opening, tongue protrusion and burning sensation. The results of this study suggest that the diffuse reflectance spectroscopy may also be considered as complementary optical techniques to monitor oral tissue transformation.
NASA Technical Reports Server (NTRS)
Orenberg, J. B.; Handy, J.
1991-01-01
Because of the power of remote sensing reflectance spectroscopy in determining mineralogy, it was used as the major method of identifying possible mineral analogs of the Martian surface. A summary of proposed Martian surface compositions from reflectance spectroscopy before 1979 was presented. Since that time, iron-rich montmorillonite clay, nanocrystalline or nanophase hematite, and palagonite were suggested as Mars soil analog materials.
van der Werf, Inez D; Calvano, Cosima D; Palmisano, Francesco; Sabbatini, Luigia
2012-03-09
A simple protocol, based on Bligh-Dyer (BD) extraction followed by MALDI-TOF-MS analysis, for fast identification of paint binders in single microsamples is proposed. For the first time it is demonstrated that the BD method is effective for the simultaneous extraction of lipids and proteins from complex, and atypical matrices, such as pigmented paint layers. The protocol makes use of an alternative denaturing anionic detergent (RapiGest™) in order to improve efficiency of protein digestion and purification step. Detection of various lipid classes, such as triacylglycerols (TAGs) and phospholipids (PLs), and their oxidation by-products was accomplished, whereas proteins could be identified by peptide mass fingerprinting. The effect of pigments on ageing of lipids and proteins was also investigated. Finally, the proposed protocol was successfully applied to the study of a late-15th century Italian panel painting allowing the identification of various proteinaceous and lipid sections in organic binders, such as egg yolk, egg white, animal glue, casein, and drying oil. Copyright © 2011 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Echard, J.-P.; Cotte, M.; Dooryhee, E.; Bertrand, L.
2008-07-01
Though ancient violins and other stringed instruments are often revered for the beauty of their varnishes, the varnishing techniques are not much known. In particular, very few detailed varnish analyses have been published so far. Since 2002, a research program at the Musée de la musique (Paris) is dedicated to a detailed description of varnishes on famous ancient musical instruments using a series of novel analytical methods. For the first time, results are presented on the study of the varnish from a late 16th century Venetian lute, using synchrotron micro-analytical methods. Identification of both organic and inorganic compounds distributed within the individual layers of a varnish microsample has been performed using spatially resolved synchrotron Fourier transform infrared microscopy. The univocal identification of the mineral phases is obtained through synchrotron powder X-ray diffraction. The materials identified may be of utmost importance to understand the varnishing process and its similarities with some painting techniques. In particular, the proteinaceous binding medium and the calcium sulfate components (bassanite and anhydrite) that have been identified in the lower layers of the varnish microsample could be related, to a certain extent, to the ground materials of earlier Italian paintings.
Metabolic profiling of Arabidopsis thaliana epidermal cells
Ebert, Berit; Zöller, Daniela; Erban, Alexander; Fehrle, Ines; Hartmann, Jürgen; Niehl, Annette; Kopka, Joachim; Fisahn, Joachim
2010-01-01
Metabolic phenotyping at cellular resolution may be considered one of the challenges in current plant physiology. A method is described which enables the cell type-specific metabolic analysis of epidermal cell types in Arabidopsis thaliana pavement, basal, and trichome cells. To achieve the required high spatial resolution, single cell sampling using microcapillaries was combined with routine gas chromatography-time of flight-mass spectrometry (GC-TOF-MS) based metabolite profiling. The identification and relative quantification of 117 mostly primary metabolites has been demonstrated. The majority, namely 90 compounds, were accessible without analytical background correction. Analyses were performed using cell type-specific pools of 200 microsampled individual cells. Moreover, among these identified metabolites, 38 exhibited differential pool sizes in trichomes, basal or pavement cells. The application of an independent component analysis confirmed the cell type-specific metabolic phenotypes. Significant pool size changes between individual cells were detectable within several classes of metabolites, namely amino acids, fatty acids and alcohols, alkanes, lipids, N-compounds, organic acids and polyhydroxy acids, polyols, sugars, sugar conjugates and phenylpropanoids. It is demonstrated here that the combination of microsampling and GC-MS based metabolite profiling provides a method to investigate the cellular metabolism of fully differentiated plant cell types in vivo. PMID:20150518
Tao, Lin-Li; Yang, Xiu-Juan; Deng, Jun-Ming; Zhang, Xi
2013-11-01
In contrast to conventional methods for the determination of meat chemical composition, near infrared reflectance spectroscopy enables rapid, simple, secure and simultaneous assessment of numerous meat properties. The present review focuses on the use of near infrared reflectance spectroscopy to predict meat chemical compositions. The potential of near infrared reflectance spectroscopy to predict crude protein, intramuscular fat, fatty acid, moisture, ash, myoglobin and collagen of beef, pork, chicken and lamb is reviewed. This paper discusses existing questions and reasons in the current research. According to the published results, although published results vary considerably, they suggest that near-infrared reflectance spectroscopy shows a great potential to replace the expensive and time-consuming chemical analysis of meat composition. In particular, under commercial conditions where simultaneous measurements of different chemical components are required, near infrared reflectance spectroscopy is expected to be the method of choice. The majority of studies selected feature-related wavelengths using principal components regression, developed the calibration model using partial least squares and modified partial least squares, and estimated the prediction accuracy by means of cross-validation using the same sample set previously used for the calibration. Meat fatty acid composition predicted by near-infrared spectroscopy and non-destructive prediction and visualization of chemical composition in meat using near-infrared hyperspectral imaging and multivariate regression are the hot studying field now. On the other hand, near infrared reflectance spectroscopy shows great difference for predicting different attributes of meat quality which are closely related to the selection of calibration sample set, preprocessing of near-infrared spectroscopy and modeling approach. Sample preparation also has an important effect on the reliability of NIR prediction; in particular, lack of homogeneity of the meat samples influenced the accuracy of estimation of chemical components. In general the predicting results of intramuscular fat, fatty acid and moisture are best, the predicting results of crude protein and myoglobin are better, while the predicting results of ash and collagen are less accurate.
Korfmacher, Walter; Luo, Yongyi; Ho, Stacy; Sun, Wei; Shen, Liduo; Wang, Jie; Wu, Zhongtao; Guo, Yang; Snow, Gregory; O'Shea, Thomas
2015-01-01
Serial sampling methods have been used for rat pharmacokinetic (PK) studies for over 20 years. Currently, it is still common to take 200-250 μL of blood at each timepoint when performing a PK study in rats and using serial sampling. While several techniques have been employed for collecting blood samples from rats, there is only limited published data to compare these methods. Recently, microsampling (≤ 50 μL) techniques have been reported as an alternative process for collecting blood samples from rats. In this report, five compounds were dosed orally into rats. For three proprietary compounds, jugular vein cannula (JVC) sampling was used to collect whole blood and plasma samples and capillary microsampling (CMS) was used to collect blood samples from the tail vein of the same animal. For the two other compounds, marketed drugs fluoxetine and glipizide, JVC sampling was used to collect both whole blood and blood CMS samples while tail-vein sampling from the same rats was also used to collect both whole blood and blood CMS samples. For the three proprietary compounds, the blood AUC as well as the blood concentration-time profile that were obtained from the tail vein were different from those obtained via JVC sampling. For fluoxetine, the blood total exposure (AUC) was not statistically different when comparing tail-vein sampling to JVC sampling, however the blood concentration-time profile that was obtained from the tail vein was different than the one obtained from JVC sampling. For glipizide, the blood AUC and concentration-time profile were not statistically different when comparing the tail-vein sampling to the JVC sampling. For both fluoxetine and glipizide, the blood concentration profiles obtained from CMS were equivalent to the blood concentration profiles obtained from the standard whole blood sampling, collected at the same sampling site. The data in this report provide strong evidence that blood CMS is a valuable small volume blood sampling approach for rats and that it provides results for test compound concentrations that are equivalent to those obtained from traditional whole blood sampling. The data also suggest that for some compounds, the concentration-time profile that is obtained for a test compound based on sampling from a rat tail vein may be different from that obtained from rat JVC sampling. In some cases, this shift in the concentration-time profile will result in different PK parameters for the test compound. Based on these observations, it is recommended that a consistent blood sampling method should be used for serial microsampling in discovery rat PK studies when testing multiple new chemical entities. If the rat tail vein sampling method is selected for PK screening, then conducting a bridging study on the lead compound is recommended to confirm that the rat PK obtained from JVC sampling is comparable to the tail-vein sampling. Copyright © 2015 Elsevier Inc. All rights reserved.
Volani, Chiara; Caprioli, Giulia; Calderisi, Giovanni; Sigurdsson, Baldur B; Rainer, Johannes; Gentilini, Ivo; Hicks, Andrew A; Pramstaller, Peter P; Weiss, Guenter; Smarason, Sigurdur V; Paglia, Giuseppe
2017-10-01
Volumetric absorptive microsampling (VAMS) is a novel approach that allows single-drop (10 μL) blood collection. Integration of VAMS with mass spectrometry (MS)-based untargeted metabolomics is an attractive solution for both human and animal studies. However, to boost the use of VAMS in metabolomics, key pre-analytical questions need to be addressed. Therefore, in this work, we integrated VAMS in a MS-based untargeted metabolomics workflow and investigated pre-analytical strategies such as sample extraction procedures and metabolome stability at different storage conditions. We first evaluated the best extraction procedure for the polar metabolome and found that the highest number and amount of metabolites were recovered upon extraction with acetonitrile/water (70:30). In contrast, basic conditions (pH 9) resulted in divergent metabolite profiles mainly resulting from the extraction of intracellular metabolites originating from red blood cells. In addition, the prolonged storage of blood samples at room temperature caused significant changes in metabolome composition, but once the VAMS devices were stored at - 80 °C, the metabolome remained stable for up to 6 months. The time used for drying the sample did also affect the metabolome. In fact, some metabolites were rapidly degraded or accumulated in the sample during the first 48 h at room temperature, indicating that a longer drying step will significantly change the concentration in the sample. Graphical abstract Volumetric absorptive microsampling (VAMS) is a novel technology that allows single-drop blood collection and, in combination with mass spectrometry (MS)-based untargeted metabolomics, represents an attractive solution for both human and animal studies. In this work, we integrated VAMS in a MS-based untargeted metabolomics workflow and investigated pre-analytical strategies such as sample extraction procedures and metabolome stability at different storage conditions. The latter revealed that prolonged storage of blood samples at room temperature caused significant changes in metabolome composition, but if VAMS devices were stored at - 80 °C, the metabolome remained stable for up to 6 months.
Temperature-related degradation and colour changes of historic paintings containing vivianite
NASA Astrophysics Data System (ADS)
Čermáková, Zdeňka; Švarcová, Silvie; Hradilová, Janka; Bezdička, Petr; Lančok, Adriana; Vašutová, Vlasta; Blažek, Jan; Hradil, David
2015-04-01
Temperature-related degradation of pure synthetic as well as partly oxidised natural vivianite has been studied by high-temperature X-ray diffraction (HT-XRD) covering the whole extent of the temperature-related stability of its structure. While temperatures around 70 °C are already damaging to vivianite, exposition to 160 °C results in complete amorphisation of both the vivianite and its oxidation products. As indicated by Mössbauer spectroscopy, temperature-induced oxidation of vivianite starts at 90 °C. To study the occurring structural as well as accompanying colour changes in more detail, model vivianite paint layer samples with different historic binders were prepared and subjected to increased temperatures. Exposition to 80 °C caused pronounced colour changes of all the samples: ground natural blue vivianite became grey - a colour change which has been described in actual works of art. Regarding the binders, the oil seemed to facilitate the transfer of heat to vivianite's grains. To simulate conditions of conservation treatment under which the painting is exposed to increased temperatures, oil-on-canvas mock-ups with vivianite were prepared and relined in a traditional way using iron. The treatment affected preferentially larger grains of vivianite; the micro-samples documented their change to grey, and their Raman spectra showed the change from vivianite to metavivianite.
NASA Astrophysics Data System (ADS)
Powell, G. L.; Dobbins, A.; Cristy, S. S.; Cliff, T. L.; Meyer, H. M., III; Lucania, J.; Milosevic, Milan
1994-01-01
This report describes the application of reflectance FTIR spectroscopy to the measurement of the oxidation rate of uranium by environmental gases near room temperature. It also describes very efficient evacuable cells designed for 75 degree(s) external reflectance with polarized light and for diffuse reflectance using mid-infrared FTIR spectroscopy. These cells, along with functionally similar remote sensing accessories, have been applied to the study of the oxidation of uranium metal in air, oxygen, and water vapor by precisely measuring the 575 cm-1 band of UO2 and other properties of the corrosion film such as absorbed water and reflective losses caused by film degradation related to pitting or nucleation phenomena.
Konegger-Kappel, Stefanie; Prohaska, Thomas
2016-01-01
Laser ablation-multi-collector-inductively coupled plasma mass spectrometry (LA-MC-ICP-MS) was optimized and investigated with respect to its performance for determining spatially resolved Pu isotopic signatures within radioactive fuel particle clusters. Fuel particles had been emitted from the Chernobyl nuclear power plant (ChNPP) where the 1986 accident occurred and were deposited in the surrounding soil, where weathering processes caused their transformation into radioactive clusters, so-called micro-samples. The size of the investigated micro-samples, which showed surface alpha activities below 40 mBq, ranged from about 200 to 1000 μm. Direct single static point ablations allowed to identify variations of Pu isotopic signatures not only between distinct fuel particle clusters but also within individual clusters. The resolution was limited to 100 to 120 μm as a result of the applied laser ablation spot sizes and the resolving power of the nuclear track radiography methodology that was applied for particle pre-selection. The determined (242)Pu/(239)Pu and (240)Pu/(239)Pu isotope ratios showed a variation from low to high Pu isotope ratios, ranging from 0.007(2) to 0.047(8) for (242)Pu/(239)Pu and from 0.183(13) to 0.577(40) for (240)Pu/(239)Pu. In contrast to other studies, the applied methodology allowed for the first time to display the Pu isotopic distribution in the Chernobyl fallout, which reflects the differences in the spent fuel composition over the reactor core. The measured Pu isotopic signatures are in good agreement with the expected Pu isotopic composition distribution that is typical for a RBMK-1000 reactor, indicating that the analyzed samples are originating from the ill-fated Chernobyl reactor. The average Pu isotope ratios [(240)Pu/(239)Pu = 0.388(86), (242)Pu/(239)Pu = 0.028(11)] that were calculated from all investigated samples (n = 48) correspond well to previously published results of Pu analyses in contaminated samples from the vicinity of the Chernobyl NPP [e.g. (240)Pu/(239)Pu = 0.394(2) and (242)Pu/(239)Pu = 0.027(1); Nunnemann et al. (J Alloys Compd 271-273:45-48, 1998)].
Chekri, Rachida; Noël, Laurent; Vastel, Christelle; Millour, Sandrine; Kadar, Ali; Guérin, Thierry
2010-01-01
This paper describes a validation process in compliance with the NFIEN ISO/IEC 17025 standard for the determination of the macrominerals calcium, magnesium, sodium, and potassium in foodstuffs by microsampling with flame atomic absorption spectrometry after closed-vessel microwave digestion. The French Standards Commission (Agence Francaise de Normalisation) standards NF V03-110, NF EN V03-115, and XP T-90-210 were used to evaluate this method. The method was validated in the context of an analysis of the 1322 food samples of the second French Total Diet Study (TDS). Several performance criteria (linearity, LOQ, specificity, trueness, precision under repeatability conditions, and intermediate precision reproducibility) were evaluated. Furthermore, the method was monitored by several internal quality controls. The LOQ values obtained (25, 5, 8.3, and 8.3 mg/kg for Ca, Mg, Na, and K, respectively) were in compliance with the needs of the TDS. The method provided accurate results as demonstrated by a repeatability CV (CVr) of < 7% and a reproducibility CV (CVR) of < 12% for all the elements. Therefore, the results indicated that this method could be used in the laboratory for the routine determination of these four elements in foodstuffs with acceptable analytical performance.
Alothman, Zeid A; Habila, Mohamed; Yilmaz, Erkan; Soylak, Mustafa
2013-01-01
A simple, environmentally friendly, and efficient dispersive liquid-liquid microextraction method combined with microsample injection flame atomic absorption spectrometry was developed for the separation and preconcentration of Cu(II). 2-(5-Bromo-2-pyridylazo)-5-(diethylamino)phenol (5-Br-PADAP) was used to form a hydrophobic complex of Cu(II) ions in the aqueous phase before extraction. To extract the Cu(II)-5-Br-PADAP complex from the aqueous phase to the organic phase, 2.0 mL of acetone as a disperser solvent and 200 microL of chloroform as an extraction solvent were used. The influences of important analytical parameters, such as the pH, types and volumes of the extraction and disperser solvents, amount of chelating agent, sample volume, and matrix effects, on the microextraction procedure were evaluated and optimized. Using the optimal conditions, the LOD, LOQ, preconcentration factor, and RSD were determined to be 1.4 microg/L, 4.7 microg/L, 120, and 6.5%, respectively. The accuracy of the proposed method was investigated using standard addition/recovery tests. The analysis of certified reference materials produced satisfactory analytical results. The developed method was applied for the determination of Cu in real samples.
Di Salvo, Sara; Casalini, Martina; Marchionni, Sara; Adani, Teresa; Ulivi, Maurizio; Tommasini, Simone; Avanzinelli, Riccardo; Mazza, Paul P. A.; Francalanci, Lorella
2018-01-01
An analytical protocol for high-precision, in situ microscale isotopic investigations is presented here, which combines the use of a high-performing mechanical microsampling device and high-precision TIMS measurements on micro-Sr samples, allowing for excellent results both in accuracy and precision. The present paper is a detailed methodological description of the whole analytical procedure from sampling to elemental purification and Sr-isotope measurements. The method offers the potential to attain isotope data at the microscale on a wide range of solid materials with the use of minimally invasive sampling. In addition, we present three significant case studies for geological and life sciences, as examples of the various applications of microscale 87Sr/86Sr isotope ratios, concerning (i) the pre-eruptive mechanisms triggering recent eruptions at Nisyros volcano (Greece), (ii) the dynamics involved with the initial magma ascent during Eyjafjallajökull volcano's (Iceland) 2010 eruption, which are usually related to the precursory signals of the eruption, and (iii) the environmental context of a MIS 3 cave bear, Ursus spelaeus. The studied cases show the robustness of the methods, which can be also be applied in other areas, such as cultural heritage, archaeology, petrology, and forensic sciences. PMID:29850369
Barco, Sebastiano; Castagnola, Elio; Moscatelli, Andrea; Rudge, James; Tripodi, Gino; Cangemi, Giuliana
2017-10-25
In this paper we show the development and validation of a volumetric absorptive microsampling (VAMS™)-LC-MS/MS method for the simultaneous quantification of four antibiotics: piperacillin-tazobactam, meropenem, linezolid and ceftazidime in 10μL human blood. The novel VAMS-LC-MS/MS method has been compared with a dried blood spot (DBS)-based method in terms of impact of hematocrit (HCT) on accuracy, reproducibility, recovery and matrix effect. Antibiotics were extracted from VAMS and DBS by protein precipitation with methanol after a re-hydration step at 37°C for 10min. LC-MS/MS was carried out on a Thermo Scientific™ TSQ Quantum™ Access MAX triple quadrupole coupled to an Accela ™UHPLC system. The VAMS-LC-MS/MS method is selective, precise and reproducible. In contrast to DBS, it allows an accurate quantification without any HCT influence. It has been applied to samples derived from pediatric patients under therapy. VAMS is a valid alternative sampling strategy for the quantification of antibiotics and is valuable in support of clinical PK/PD studies and consequently therapeutic drug monitoring (TDM) in pediatrics. Copyright © 2017 Elsevier B.V. All rights reserved.
In vivo soft tissue differentiation by diffuse reflectance spectroscopy: preliminary results
NASA Astrophysics Data System (ADS)
Zam, Azhar; Stelzle, Florian; Tangermann-Gerk, Katja; Adler, Werner; Nkenke, Emeka; Neukam, Friedrich Wilhelm; Schmidt, Michael; Douplik, Alexandre
Remote laser surgery does not provide haptic feedback to operate layer by layer and preserve vulnerable anatomical structures like nerve tissue or blood vessels. The aim of this study is identification of soft tissue in vivo by diffuse reflectance spectroscopy to set the base for a feedback control system to enhance nerve preservation in oral and maxillofacial laser surgery. Various soft tissues can be identified by diffuse reflectance spectroscopy in vivo. The results may set the base for a feedback system to prevent nerve damage during oral and maxillofacial laser surgery.
Anatomy of point-contact Andreev reflection spectroscopy from the experimental point of view
NASA Astrophysics Data System (ADS)
Naidyuk, Yu. G.; Gloos, K.
2018-04-01
We review applications of point-contact Andreev-reflection spectroscopy to study elemental superconductors, where theoretical conditions for the smallness of the point-contact size with respect to the characteristic lengths in the superconductor can be satisfied. We discuss existing theoretical models and identify new issues that have to be solved, especially when applying this method to investigate more complex superconductors. We will also demonstrate that some aspects of point-contact Andreev-reflection spectroscopy still need to be addressed even when investigating ordinary metals.
Villaverde Bonilla, Valentín; Ródenas Marín, Isabel; Murcia Mascarós, Sonia
2016-01-01
In this work we analyze the pigments used in the decoration of red and yellow motifs present in the portable art of the Parpalló Cave (Gandía, Spain), one of the most important Palaeolithic sites in the Spanish Mediterranean region. Energy dispersive X-ray fluorescence spectrometry (EDXRF) and spectrophotometry in the visible region (CIEL*a*b*color coordinates and spectral reflectance curves) were used to perform in situ fast analyses of the red and yellow motifs with portable equipment and to characterize their elemental composition and their colorimetric perception, respectively. According to the elemental composition, the intensity of the fluorescence iron signals in red and yellow motifs are higher than average values in the rock substrates. As expected, red motifs possess high values of the chromatic coordinate a* and yellow motifs possess high values of b*. This characterization was complemented with FT-IR analyses of microsamples detached from the red and yellow colored zones of a small set of plaquettes. Our results show that the artists used red and yellow pigments in the decoration likely derived from natural iron oxides as hematite and goethite. PMID:27732605
Roldán García, Clodoaldo; Villaverde Bonilla, Valentín; Ródenas Marín, Isabel; Murcia Mascarós, Sonia
2016-01-01
In this work we analyze the pigments used in the decoration of red and yellow motifs present in the portable art of the Parpalló Cave (Gandía, Spain), one of the most important Palaeolithic sites in the Spanish Mediterranean region. Energy dispersive X-ray fluorescence spectrometry (EDXRF) and spectrophotometry in the visible region (CIEL*a*b*color coordinates and spectral reflectance curves) were used to perform in situ fast analyses of the red and yellow motifs with portable equipment and to characterize their elemental composition and their colorimetric perception, respectively. According to the elemental composition, the intensity of the fluorescence iron signals in red and yellow motifs are higher than average values in the rock substrates. As expected, red motifs possess high values of the chromatic coordinate a* and yellow motifs possess high values of b*. This characterization was complemented with FT-IR analyses of microsamples detached from the red and yellow colored zones of a small set of plaquettes. Our results show that the artists used red and yellow pigments in the decoration likely derived from natural iron oxides as hematite and goethite.
NASA Astrophysics Data System (ADS)
Haq, Quazi M. I.; Mabood, Fazal; Naureen, Zakira; Al-Harrasi, Ahmed; Gilani, Sayed A.; Hussain, Javid; Jabeen, Farah; Khan, Ajmal; Al-Sabari, Ruqaya S. M.; Al-khanbashi, Fatema H. S.; Al-Fahdi, Amira A. M.; Al-Zaabi, Ahoud K. A.; Al-Shuraiqi, Fatma A. M.; Al-Bahaisi, Iman M.
2018-06-01
Nucleic acid & serology based methods have revolutionized plant disease detection, however, they are not very reliable at asymptomatic stage, especially in case of pathogen with systemic infection, in addition, they need at least 1-2 days for sample harvesting, processing, and analysis. In this study, two reflectance spectroscopies i.e. Near Infrared reflectance spectroscopy (NIR) and Fourier-Transform-Infrared spectroscopy with Attenuated Total Reflection (FT-IR, ATR) coupled with multivariate exploratory methods like Principle Component Analysis (PCA) and Partial least square discriminant analysis (PLS-DA) have been deployed to detect begomovirus infection in papaya leaves. The application of those techniques demonstrates that they are very useful for robust in vivo detection of plant begomovirus infection. These methods are simple, sensitive, reproducible, precise, and do not require any lengthy samples preparation procedures.
Fourier Transform Infrared Spectroscopy Part III. Applications.
ERIC Educational Resources Information Center
Perkins, W. D.
1987-01-01
Discusses the use of the FT-IR spectrometer in analyses that were previously avoided. Examines some of the applications of this spectroscopy with aqueous solutions, circular internal reflection, samples with low transmission, diffuse reflectance, infrared emission, and the infrared microscope. (TW)
A study of muscular tissue of animal origin by reflection-spectroscopy methods
NASA Astrophysics Data System (ADS)
Plotnikova, L. V.; Nechiporenko, A. P.; Orekhova, S. M.; Plotnikov, P. P.; Ishevskii, A. L.
2017-06-01
A comparative analysis of the spectral characteristics of the surface of muscular tissue of animal origin (pork) and its main components has been performed by the methods of diffuse reflection electronic spectroscopy (DRES) and frustrated total internal reflection IR spectroscopy. The experiments have shown that the application of the DRES method makes it possible to detect more pronounced changes in the surface optical characteristics of muscular tissue and obtain electronic spectra containing information about the component composition of its main parts under successive extraction of sarcoplasmic materials, myofibrillar proteins of the actomyosin complex, and stroma mucopolysaccharides.
Infrared Spectroscopy of Explosives Residues: Measurement Techniques and Spectral Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Phillips, Mark C.; Bernacki, Bruce E.
2015-03-11
Infrared laser spectroscopy of explosives is a promising technique for standoff and non-contact detection applications. However, the interpretation of spectra obtained in typical standoff measurement configurations presents numerous challenges. Understanding the variability in observed spectra from explosives residues and particles is crucial for design and implementation of detection algorithms with high detection confidence and low false alarm probability. We discuss a series of infrared spectroscopic techniques applied toward measuring and interpreting the reflectance spectra obtained from explosives particles and residues. These techniques utilize the high spectral radiance, broad tuning range, rapid wavelength tuning, high scan reproducibility, and low noise ofmore » an external cavity quantum cascade laser (ECQCL) system developed at Pacific Northwest National Laboratory. The ECQCL source permits measurements in configurations which would be either impractical or overly time-consuming with broadband, incoherent infrared sources, and enables a combination of rapid measurement speed and high detection sensitivity. The spectroscopic methods employed include standoff hyperspectral reflectance imaging, quantitative measurements of diffuse reflectance spectra, reflection-absorption infrared spectroscopy, microscopic imaging and spectroscopy, and nano-scale imaging and spectroscopy. Measurements of explosives particles and residues reveal important factors affecting observed reflectance spectra, including measurement geometry, substrate on which the explosives are deposited, and morphological effects such as particle shape, size, orientation, and crystal structure.« less
Spectroscopic sensitivity of real-time, rapidly induced phytochemical change in response to damage.
Couture, John J; Serbin, Shawn P; Townsend, Philip A
2013-04-01
An ecological consequence of plant-herbivore interactions is the phytochemical induction of defenses in response to insect damage. Here, we used reflectance spectroscopy to characterize the foliar induction profile of cardenolides in Asclepias syriaca in response to damage, tracked in vivo changes and examined the influence of multiple plant traits on cardenolide concentrations. Foliar cardenolide concentrations were measured at specific time points following damage to capture their induction profile. Partial least-squares regression (PLSR) modeling was employed to calibrate cardenolide concentrations to reflectance spectroscopy. In addition, subsets of plants were either repeatedly sampled to track in vivo changes or modified to reduce latex flow to damaged areas. Cardenolide concentrations and the induction profile of A. syriaca were well predicted using models derived from reflectance spectroscopy, and this held true for repeatedly sampled plants. Correlations between cardenolides and other foliar-related variables were weak or not significant. Plant modification for latex reduction inhibited an induced cardenolide response. Our findings show that reflectance spectroscopy can characterize rapid phytochemical changes in vivo. We used reflectance spectroscopy to identify the mechanisms behind the production of plant secondary metabolites, simultaneously characterizing multiple foliar constituents. In this case, cardenolide induction appears to be largely driven by enhanced latex delivery to leaves following damage. © 2013 The Authors. New Phytologist © 2013 New Phytologist Trust.
NASA Astrophysics Data System (ADS)
Zhang, X.; Karanassios, V.
2012-06-01
A solar-powered, battery-operated, atmospheric-pressure, self-igniting microplasma the size of a sugar-cube developed on a hybrid, 3d-chip is described. Rapid prototyping of the 3d-chip; some fundamental aspects and a brief characterization of its background spectral emission using a portable, fiber-optic spectrometer are discussed.
Touch Spray Mass Spectrometry for In Situ Analysis of Complex Samples
Kerian, Kevin S.; Jarmusch, Alan K.; Cooks, R. Graham
2014-01-01
Touch spray, a spray-based ambient in-situ ionization method, uses a small probe, e.g. a teasing needle to pick up sample and the application of voltage and solvent to cause field-induced droplet emission. Compounds extracted from the microsample are incorporated into the sprayed micro droplets. Performance tests include disease state of tissue, microorganism identification, and therapeutic drug quantitation. Chemical derivatization is performed simultaneously with ionization. PMID:24756256
NASA Astrophysics Data System (ADS)
Fajardo, Mario; Neel, Christopher; Lacina, David
2017-06-01
We report (null) results of experiments testing the hypothesis that mid-infrared (mid-IR) spectroscopy can be used to distinguish samples of poly[methyl methacrylate] (PMMA) obtained from different commercial suppliers. This work was motivated by the desire for a simple non-destructive and non-invasive test for pre-sorting PMMA samples prior to use in shock and high-strain-rate experiments, where PMMA is commonly used as a standard material. We discuss: our choice of mid-IR external reflectance spectroscopy, our approach to recording reflectance spectra at near-normal (θ = 0 + / - 5 degree) incidence and for extracting the wavelength-weighted absorption spectrum from the raw reflectance data via a Kramers-Krönig analysis. We employ extensive signal, which necessitates adopting a special experimental protocol to mitigate the effects of instrumental drift. Finally, we report spectra of three PMMA samples with different commercial pedigrees, and show that they are virtually identical (+ / - 1 % error, 95% confidence); obviating the use of mid-IR reflectance spectroscopy to tell the samples apart.
2015-10-15
to state-of- hydration . Polarization modulated infrared reflection- absorption spectroscopy experiments are enabled by the use of a spin-coater to coat...NAME(S) AND ADDRESS (ES) U.S. Army Research Office P.O. Box 12211 Research Triangle Park, NC 27709-2211 SPEEK, Nafion, Ionomers, state-of- hydration ...enabled correlation of the exchange site structure to state-of- hydration . Polarization modulated infrared reflection-absorption spectroscopy experiments
Developing New Methods for Microsampling and Sm/Nd Dating of Zoned Garnet
NASA Astrophysics Data System (ADS)
Pollington, A. D.; Baxter, E. F.
2007-12-01
Garnets provide one of the Earth Science community's most useful tools for studying rates, duration and timing of crustal processes. In this study we describe new techniques for fine sampling of multiple growth zones of garnet and Sm/Nd dating of each individual zone. We test these techniques on large (>5cm) garnets from a shear zone in the Tauern Window of Austria where we seek to quantify the growth history of garnet in a manner similar to dating tree rings. Microsampling permits a more precise quantification of duration, episodicity and kinetics of metamorphic reactions. Past studies of garnet growth duration - based on core and rim garnet ages - have been limited by sampling methods for extracting discrete, and accurate, growth zones. Modeling of radial growth symmetry in garnet shows that previous studies may underestimate garnet growth duration by as much as 50%. We are able to dramatically improve microsampling by using microdrilling guided by chemical maps of the garnet composition. This provides much improved precision and accuracy in sampling. By using chemical mapping of the garnet we can be sure that we are correctly sampling narrow (~500 micron wide) growth (i.e. age) zones rather than smearing and averaging multiple growth zones together. In principle, tens of growth zones (and ages) spanning the entire interval of garnet growth may be sampled and resolved. Microdrilled domains, the results of which are an ultrafine powder, are drilled and collected in water. Due to the adverse geochronological effect of unavoidable micro-inclusions in garnet, we have tested several partial dissolution techniques to cleanse the garnet of inclusions and yield higher 147Sm/144Nd and hence, more precise ages. Analysis of a finely crushed bulk Tauern Window garnet sample after HF/HClO3 cleansing indicates that 147Sm/144Nd at least as high as 0.89 is attainable in this particular sample, but cleansing efforts on microdrilled powders have thus far failed to yield such high ratios suggesting that the powders respond in unexpectedly different ways to our standard garnet cleansing procedures. Preliminary Sm/Nd age analysis of bulk garnet confirms a ~25Ma age for garnet growth. Progress in our inclusion cleansing procedures on microdrilled powders will be reported.
Ojeda, Jesús J; Romero-González, María E; Banwart, Steven A
2009-08-01
Reflectance micro-Fourier transform infrared (FT-IR) analysis has been applied to characterize biofilm formation of Aquabacterium commune, a common microorganism present on drinking water distribution systems, onto the increasingly popular pipe material stainless steel EN1.4307. The applicability of the reflectance micro-FT-IR technique for analyzing the bacterial functional groups is discussed, and the results are compared to spectra obtained using more conventional FT-IR techniques: transmission micro-FT-IR, attenuated transmitted reflectance (ATR), and KBr pellets. The differences between the infrared spectra of wet and dried bacteria, as well as free versus attached bacteria, are also discussed. The spectra obtained using reflectance micro-FT-IR spectroscopy were comparable to those obtained using other FT-IR techniques. The absence of sample preparation, the potential to analyze intact samples, and the ability to characterize opaque and thick samples without the need to transfer the bacterial samples to an infrared transparent medium or produce a pure culture were the main advantages of reflectance micro-FT-IR spectroscopy.
Chen, Qian-Qian; Liu, Xiao-Dong; Liu, Wen-Qi; Jiang, Shan
2011-10-01
Compared with traditional chemical analysis methods, reflectance spectroscopy has the advantages of speed, minimal or no sample preparation, non-destruction, and low cost. In order to explore the potential application of spectroscopy technology in the paleolimnological study on Antarctic lakes, we took a lake sediment core in Mochou Lake at Zhongshan Station of Antarctic, and analyzed the near infrared reflectance spectroscopy (NIRS) data in the sedimentary samples. The results showed that the factor loadings of principal component analysis (PCA) displayed very similar depth-profile change pattern with the S2 index, a reliable proxy for the change in historical lake primary productivity. The correlation analysis showed that the values of PCA factor loading and S2 were correlated significantly, suggesting that it is feasible to infer paleoproductivity changes recorded in Antarctic lakes using NIRS technology. Compared to the traditional method of the trough area between 650 and 700 nm, the authors found that the PCA statistical approach was more accurate for reconstructing the change in historical lake primary productivity. The results reported here demonstrate that reflectance spectroscopy can provide a rapid method for the reconstruction of lake palaeoenviro nmental change in the remote Antarctic regions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ghamsari, Behnood G.; Tosado, Jacob; Yamamoto, Mahito
Here, we have experimentally studied the optical refractive index of few-layer graphene through reflection spectroscopy at visible wavelengths. A laser scanning microscope (LSM) with a coherent supercontinuum laser source measured the reflectivity of an exfoliated graphene flake on a Si/SiO 2 substrate, containing monolayer, bilayer and trilayer areas, as the wavelength of the laser was varied from 545nm to 710nm. The complex refractive index of few-layer graphene, n-ik, was extracted from the reflectivity contrast to the bare substrate and the Fresnel reflection theory. Since the SiO 2 thickness enters to the modeling as a parameter, it was precisely measured atmore » the location of the sample. It was found that a common constant optical index cannot explain the wavelength-dependent reflectivity data for single-, double- and three-layer graphene simultaneously, but rather each individual few-layer graphene possesses a unique optical index whose complex values were precisely and accurately determined from the experimental data.« less
Ghamsari, Behnood G.; Tosado, Jacob; Yamamoto, Mahito; ...
2016-09-29
Here, we have experimentally studied the optical refractive index of few-layer graphene through reflection spectroscopy at visible wavelengths. A laser scanning microscope (LSM) with a coherent supercontinuum laser source measured the reflectivity of an exfoliated graphene flake on a Si/SiO 2 substrate, containing monolayer, bilayer and trilayer areas, as the wavelength of the laser was varied from 545nm to 710nm. The complex refractive index of few-layer graphene, n-ik, was extracted from the reflectivity contrast to the bare substrate and the Fresnel reflection theory. Since the SiO 2 thickness enters to the modeling as a parameter, it was precisely measured atmore » the location of the sample. It was found that a common constant optical index cannot explain the wavelength-dependent reflectivity data for single-, double- and three-layer graphene simultaneously, but rather each individual few-layer graphene possesses a unique optical index whose complex values were precisely and accurately determined from the experimental data.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Webb, J.D.; Schissel, P.; Czanderna, A.W.
1981-12-01
Reflection-absorbance spectroscopy has been used to obtain analytical information on samples of polymer/metal multilayer stacks subjected to degradative factors. The capabilities of the apparatus are summarized and representative data from initial studies are presented. (LEW)
Roucher, Véronique Ferchaud; Desnots, Emmanuelle; Naël, Charlotte; Agnoux, Aurore Martin; Alexandre-Gouabau, Marie-Cécile; Darmaun, Dominique; Boquien, Clair-Yves
2013-01-01
Although free amino acids (FAA) account for a small fraction of total nitrogen in mammalian milk, they are more abundant in human milk than in most formulas, and may serve as a readily available source of amino acids for protein synthesis, as well as fulfill specific physiologic roles. We used reversed phase Ultra Performance Liquid Chromatography (UPLC) coupled to electrospray ionization tandem mass spectrometry (ESI-MS/MS) technique for FAA profiling in milks from three species (human, rat and cow) with a simple and rapid sample preparation. The derivatization procedure chosen, combined with UPLC-ESI-MS/MS allowed the quantitation of 21 FAA using labeled amino acids (Internal Standards) over a 10 min run time in micro-samples of mammalian milk (50 μL). The low limit of quantitation was 0.05 pmol/μL for most FAA with good repeatability and reproducibility (mean CV of 5.1%). Higher levels of total FAA were found in human (3032 μM) and rat milk (3460 μM) than in bovine milk (240 μM), with wide differences in the abundances of specific FAA between species. This robust analytical method could be applied to monitor FAA profile in human breast milk, and open the way to individualized adjustment of FAA content for the nutritional management of infants.
Horn, P L; Neil, H L; Paul, L J; Marriott, P
2010-11-01
Age validation of bluenose Hyperoglyphe antarctica was sought using the independent bomb chronometer procedure. Radiocarbon ((14) C) levels were measured in core micro-samples from 12 otoliths that had been aged using a zone count method. The core (14) C measurement for each fish was compared with the value on a surface water reference curve for the calculated birth year of the fish. There was good agreement, indicating that the line-count ageing method described here is not substantially biased. A second micro-sample was also taken near the edge of nine of the otolith cross-sections to help define a bomb-carbon curve for waters deeper than 200-300 m. There appears to be a 10 to 15 year lag in the time it takes the (14) C to reach the waters where adult H. antarctica are concentrated. The maximum estimated age of this species was 76 years, and females grow significantly larger than males. Von Bertalanffy growth curves were estimated, and although they fit the available data reasonably well, the lack of aged juvenile fish results in the K and t(0) parameters being biologically meaningless. Consequently, curves that are likely to better represent population growth were estimated by forcing t(0) to be -0·5. © 2010 NIWA. Journal of Fish Biology © 2010 The Fisheries Society of the British Isles.
Spilker, Mary E; Chung, Heekyung; Visswanathan, Ravi; Bagrodia, Shubha; Gernhardt, Steven; Fantin, Valeria R; Ellies, Lesley G
2017-07-01
1. Leukotriene B4 (LTB4) is a proinflammatory mediator important in the progression of a number of inflammatory diseases. Preclinical models can explore the role of LTB4 in pathophysiology using tool compounds, such as CP-105696, that modulate its activity. To support preclinical pharmacology studies, micro-sampling techniques and mathematical modeling were used to determine the pharmacokinetics of CP-105696 in mice within the context of systemic inflammation induced by a high-fat diet (HFD). 2. Following oral administration of doses > 35 mg/kg, CP-105696 kinetics can be described by a one-compartment model with first order absorption. The compound's half-life is 44-62 h with an apparent volume of distribution of 0.51-0.72 L/kg. Exposures in animals fed an HFD are within 2-fold of those fed a normal chow diet. Daily dosing at 100 mg/kg was not tolerated and resulted in a >20% weight loss in the mice. 3. CP-105696's long half-life has the potential to support a twice weekly dosing schedule. Given that most chronic inflammatory diseases will require long-term therapies, these results are useful in determining the optimal dosing schedules for preclinical studies using CP-105696.
Reiss, Stephan; Sperlich, K; Hovakimyan, M; Martius, P; Guthoff, R F; Stolz, H; Stachs, O
2012-08-01
Use of Brillouin spectroscopy in ophthalmology enables noninvasive, spatially resolved determination of the rheological properties of crystalline lens tissue. Furthermore, the Brillouin shift correlates with the protein concentration inside the lens. In vitro measurements on extracted porcine lenses demonstrate that results obtained with Brillouin spectroscopy depend strongly on time after death. The intensity of the Brillouin signal decreases significantly as early as 5 h postmortem. Moreover, the fluctuation of the Brillouin frequency shift inside the lens increases with postmortem time. Images of lens tissue taken with a confocal reflectance microscope between measurements reveal a degenerative aging process. These tissue changes correlate with our results from Brillouin spectroscopy. It is concluded that only in vivo measurements appropriately reflect the rheological properties of the eye lens and its protein concentration.
Enhanced Vibrational Spectroscopies as Tools for Small Molecule Biosensing
Boujday, Souhir; Lamy de la Chapelle, Marc; Srajer, Johannes; Knoll, Wolfgang
2015-01-01
In this short summary we summarize some of the latest developments in vibrational spectroscopic tools applied for the sensing of (small) molecules and biomolecules in a label-free mode of operation. We first introduce various concepts for the enhancement of InfraRed spectroscopic techniques, including the principles of Attenuated Total Reflection InfraRed (ATR-IR), (phase-modulated) InfraRed Reflection Absorption Spectroscopy (IRRAS/PM-IRRAS), and Surface Enhanced Infrared Reflection Absorption Spectroscopy (SEIRAS). Particular attention is put on the use of novel nanostructured substrates that allow for the excitation of propagating and localized surface plasmon modes aimed at operating additional enhancement mechanisms. This is then be complemented by the description of the latest development in Surface- and Tip-Enhanced Raman Spectroscopies, again with an emphasis on the detection of small molecules or bioanalytes. PMID:26343666
Astrobiology's Central Dilemma: How can we detect Life if we cannot even Define it?
NASA Astrophysics Data System (ADS)
Clark, B. C.
2001-11-01
Culling and consolidating from a collection of 102 attributes asserted as properties of Life, and the numerous Definitions of Life which invoke them, a new definition is proposed. Analysis of the pathways to proving that any given entity, from micro-sample to planetary object, harbors one or more lifeforms provides strategies for the observations, experiments and detection approaches. These are necessarily varied because of the relative accessibility/inaccessibility of the samples themselves, for example, from Mars, Europa, the ancient Earth or extra-solar system planets. A two-tiered Definition of Life has been formulated, involving both Lifeform and Organism. Devising exploration strategies with a reasonable probability of success and acceptance should proceed along the steps needed for detection and verification of the minimal properties which define Life itself. Multiple approaches, such as high resolution remote spectroscopy for detection of biomarker gases, in situ demonstrations of energy utilization to performs functions such as anabolic or catabolic transformations, achievement of demonstrated reproduction through multi-condition incubations, and probes for macromolecular biochemicals which indicate information storage should be undertaken wherever possible, as should return of samples to terrestrial laboratories for more versatile, more sensitive and more definitive examinations. Use of control samples is paramount, as is detailed understanding of the chemistry and physics of the environment which constrains the activities and tracers being sought.
NASA Astrophysics Data System (ADS)
Parsons, L. C.; Andrews, G. T.
2012-09-01
Pseudo-reflection geometry Brillouin spectroscopy can be used to probe acoustic wave dispersion approximately along the surface normal of a material system while avoiding the difficulties associated with specularly reflected light encountered in an ideal reflection configuration. As an example of its application, we show analytically that it can be used to determine both the refractive index and bulk acoustic mode velocities of optically-isotropic non-metallic materials and confirm the utility of the approach via a series of experiments on fused quartz, gallium phosphide, water, and porous silicon films.
Optical spectroscopy for quantitative sensing in human pancreatic tissues
NASA Astrophysics Data System (ADS)
Wilson, Robert H.; Chandra, Malavika; Lloyd, William; Chen, Leng-Chun; Scheiman, James; Simeone, Diane; McKenna, Barbara; Mycek, Mary-Ann
2011-07-01
Pancreatic adenocarcinoma has a five-year survival rate of only 6%, largely because current diagnostic methods cannot reliably detect the disease in its early stages. Reflectance and fluorescence spectroscopies have the potential to provide quantitative, minimally-invasive means of distinguishing pancreatic adenocarcinoma from normal pancreatic tissue and chronic pancreatitis. The first collection of wavelength-resolved reflectance and fluorescence spectra and time-resolved fluorescence decay curves from human pancreatic tissues was acquired with clinically-compatible instrumentation. Mathematical models of reflectance and fluorescence extracted parameters related to tissue morphology and biochemistry that were statistically significant for distinguishing between pancreatic tissue types. These results suggest that optical spectroscopy has the potential to detect pancreatic disease in a clinical setting.
Rui, Yu-kui; Luo, Yun-bo; Huang, Kun-lun; Wang, Wei-min; Zhang, Lu-da
2005-10-01
With the rapid development of the GMO, more and more GMO food has been pouring into the market. Much attention has been paid to GMO labeling under the controversy of GMO safety. Transgenic corns and their parents were scanned by continuous wave of near infrared diffuse reflectance spectroscopy range of 12000-4000 cm(-1); the resolution was 4 cm(-1); scanning was carried out for 64 times; BP algorithm was applied for data processing. The GMO food was easily resolved. Near-infrared diffuse reflectance spectroscopy is unpolluted and inexpensive compared with PCR and ELISA, so it is a very promising detection method for GMO food.
NASA Technical Reports Server (NTRS)
Boyce, Joseph (Technical Monitor); Mustard, John
2004-01-01
Reflectance spectroscopy has demonstrated that high albedo surfaces on Mars contain heavily altered materials with some component of hematite, poorly crystalline ferric oxides, and an undefined silicate matrix. The spectral properties of many low albedo regions indicate crystalline basalts containing both low and high calcium pyroxene, a mineralogy consistent with the basaltic SNC meteorites. The Thermal Emission Spectrometer (TES) experiment on the Mars Geochemical Surveyor has acquired critical new data relevant to surface composition and mineralogy, but in a wavelength region that is complementary to reflectance spectroscopy. The essence of the completed research was to analyze TES data in the context of reflectance data obtained by the French ISM imaging spectrometer experiment in 1989. This approach increased our understanding of the complementary nature of these wavelength regions for mineralogic determinations using actual observations of the martian surface. The research effort focused on three regions of scientific importance: Syrtis Major-Isidis Basin, Oxia Palus-Arabia, and Valles Marineris. In each region distinct spatial variations related to reflectance, and in derived mineralogic information and interpreted compositional units were analyzed. In addition, specific science questions related to the composition of volcanics and crustal evolution, soil compositions and pedogenic processes, and the relationship between pristine lithologies and weathering provided an overall science-driven framework for the work. The detailed work plan involved colocation of TES and ISM data, extraction of reflectance and emissivity spectra from areas of known reflectance variability, and quantitative analysis using factor analysis and statistical techniques to determine the degree of correspondence between these different wavelength regions. Identified coherent variations in TES spectroscopy were assessed against known atmospheric effects to validate that the variations are due to surface properties. With this new understanding of reflectance and emission spectroscopy, mineralogic interpretations were derived and applied to the science objectives of the three regions.
NASA Astrophysics Data System (ADS)
Delaney, John K.; Zeibel, Jason G.; Thoury, Mathieu; Littleton, Roy; Morales, Kathryn M.; Palmer, Michael; de la Rie, E. René
2009-07-01
Reflectance imaging spectroscopy, the collection of images in narrow spectral bands, has been developed for remote sensing of the Earth. In this paper we present findings on the use of imaging spectroscopy to identify and map artist pigments as well as to improve the visualization of preparatory sketches. Two novel hyperspectral cameras, one operating from the visible to near-infrared (VNIR) and the other in the shortwave infrared (SWIR), have been used to collect diffuse reflectance spectral image cubes on a variety of paintings. The resulting image cubes (VNIR 417 to 973 nm, 240 bands, and SWIR 970 to 1650 nm, 85 bands) were calibrated to reflectance and the resulting spectra compared with results from a fiber optics reflectance spectrometer (350 to 2500 nm). The results show good agreement between the spectra acquired with the hyperspectral cameras and those from the fiber reflectance spectrometer. For example, the primary blue pigments and their distribution in Picasso's Harlequin Musician (1924) are identified from the reflectance spectra and agree with results from X-ray fluorescence data and dispersed sample analysis. False color infrared reflectograms, obtained from the SWIR hyperspectral images, of extensively reworked paintings such as Picasso's The Tragedy (1903) are found to give improved visualization of changes made by the artist. These results show that including the NIR and SWIR spectral regions along with the visible provides for a more robust identification and mapping of artist pigments than using visible imaging spectroscopy alone.
USDA-ARS?s Scientific Manuscript database
Near Infrared (NIR) Reflectance spectroscopy has established itself as an important tool in quantifying water and oil present in various food materials. It is rapid and nondestructive, easier to use, and does not require processing the samples with corrosive chemicals that would render them non-edib...
Internal Reflection Spectra of Surface Compounds and Adsorbed Molecules
NASA Astrophysics Data System (ADS)
Zolotarev, V. M.; Lygin, V. I.; Tarasevich, B. N.
1981-01-01
The application of attenuated total reflection (ATR) spectroscopy in surface studies of inorganic adsorbents and catalysts, polymers, and optically transparent electrodes is discussed. The basic principles of ATR spectroscopy as applied to surface phenomena are considered, with special reference to thin films, industrial adsorbents and catalysts, and polymer degradation processes. 276 references.
USDA-ARS?s Scientific Manuscript database
Diffuse-Reflectance Fourier-Transform Mid-Infrared Spectroscopy (MidIR) can identify the presence of important organic functional groups in soil organic matter (SOM). Soils contain myriad organic and inorganic components that absorb in the MidIR so spectral interpretation needs to be validated in or...
USDA-ARS?s Scientific Manuscript database
Cotton fibers harvested at 18, 20, 24, 28, 32, 36 and 40 days after flowering were examined using attenuated total reflection Fourier transform-infrared (ATR FT-IR) spectroscopy. The selected harvesting points coincide with secondary cell wall (SCW) development in the fibers. Progressive but moderat...
Kajiyama, Shin'ichiro; Harada, Kazuo; Fukusaki, Eiichiro; Kobayashi, Akio
2006-12-01
The molecular constituents of the petal pigments of the Torenia plant (Torenia hybrida) were analyzed on a single-cell basis by a combination of newly developed laser-microsampling and nano-flow liquid chromatography-electro spray ionization mass spectrometry (LC-ESIMS) techniques. Our method should provide a facile method for obtaining precise metabolic profiles of each cell in a single plant tissue.
Optical spectroscopic studies of animal skin used in modeling of human cutaneous tissue
NASA Astrophysics Data System (ADS)
Drakaki, E.; Makropoulou, M.; Serafetinides, A. A.; Borisova, E.; Avramov, L.; Sianoudis, J. A.
2007-03-01
Optical spectroscopy and in particular laser-induced autofluorescence spectroscopy (LIAFS) and diffuse reflectance spectroscopy (DRS), provide excellent possibilities for real-time, noninvasive diagnosis of different skin tissue pathologies. However, the introduction of optical spectroscopy in routine medical practice demands a statistically important data collection, independent from the laser sources and detectors used. The scientists collect databases either from patients, in vivo, or they study different animal models to obtain objective information for the optical properties of various types of normal and diseased tissue. In the present work, the optical properties (fluorescence and reflectance) of two animal skin models are investigated. The aim of using animal models in optical spectroscopy investigations is to examine the statistics of the light induced effects firstly on animals, before any extrapolation effort to humans. A nitrogen laser (λ=337.1 nm) was used as an excitation source for the autofluorescence measurements, while a tungsten-halogen lamp was used for the reflectance measurements. Samples of chicken and pig skin were measured in vitro and were compared with results obtained from measurements of normal human skin in vivo. The specific features of the measured reflectance and fluorescence spectra are discussed, while the limits of data extrapolation for each skin type are also depicted.
Time in tortoiseshell: a bomb radiocarbon-validated chronology in sea turtle scutes.
Van Houtan, Kyle S; Andrews, Allen H; Jones, T Todd; Murakawa, Shawn K K; Hagemann, Molly E
2016-01-13
Some of the most basic questions of sea turtle life history are also the most elusive. Many uncertainties surround lifespan, growth rates, maturity and spatial structure, yet these are critical factors in assessing population status. Here we examine the keratinized hard tissues of the hawksbill (Eretmochelys imbricata) carapace and use bomb radiocarbon dating to estimate growth and maturity. Scutes have an established dietary record, yet the large keratin deposits of hawksbills evoke a reliable chronology. We sectioned, polished and imaged posterior marginal scutes from 36 individual hawksbills representing all life stages, several Pacific populations and spanning eight decades. We counted the apparent growth lines, microsampled along growth contours and calibrated Δ(14)C values to reference coral series. We fit von Bertalanffy growth function (VBGF) models to the results, producing a range of age estimates for each turtle. We find Hawaii hawksbills deposit eight growth lines annually (range 5-14), with model ensembles producing a somatic growth parameter (k) of 0.13 (range 0.1-0.2) and first breeding at 29 years (range 23-36). Recent bomb radiocarbon values also suggest declining trophic status. Together, our results may reflect long-term changes in the benthic community structure of Hawaii reefs, and possibly shed light on the critical population status for Hawaii hawksbills. © 2016 The Author(s).
Time in tortoiseshell: a bomb radiocarbon-validated chronology in sea turtle scutes
Van Houtan, Kyle S.; Andrews, Allen H.; Jones, T. Todd; Murakawa, Shawn K. K.; Hagemann, Molly E.
2016-01-01
Some of the most basic questions of sea turtle life history are also the most elusive. Many uncertainties surround lifespan, growth rates, maturity and spatial structure, yet these are critical factors in assessing population status. Here we examine the keratinized hard tissues of the hawksbill (Eretmochelys imbricata) carapace and use bomb radiocarbon dating to estimate growth and maturity. Scutes have an established dietary record, yet the large keratin deposits of hawksbills evoke a reliable chronology. We sectioned, polished and imaged posterior marginal scutes from 36 individual hawksbills representing all life stages, several Pacific populations and spanning eight decades. We counted the apparent growth lines, microsampled along growth contours and calibrated Δ14C values to reference coral series. We fit von Bertalanffy growth function (VBGF) models to the results, producing a range of age estimates for each turtle. We find Hawaii hawksbills deposit eight growth lines annually (range 5–14), with model ensembles producing a somatic growth parameter (k) of 0.13 (range 0.1–0.2) and first breeding at 29 years (range 23–36). Recent bomb radiocarbon values also suggest declining trophic status. Together, our results may reflect long-term changes in the benthic community structure of Hawaii reefs, and possibly shed light on the critical population status for Hawaii hawksbills. PMID:26740617
NASA Astrophysics Data System (ADS)
Lo, H. Y.; Chan, C. Y.; Ong, H. C.
2012-11-01
We have measured the radiative scattering from two-dimensional metallic arrays by using polarization-resolved reflectivity spectroscopy. We find the reflectivity spectra follow the Fano-like model that can be derived from temporal coupled mode theory and Jones matrix calculus. By orthogonally orienting the incident polarizer and the detection analyzer, reflectivity dips flip into peaks and the radiative scattering efficiency can be determined accordingly. The dependence of total radiative scattering efficiency on wavelength and hole diameter is found to agree well with Rayleigh scattering by single hole.
Physiological basis for noninvasive skin cancer diagnosis using diffuse reflectance spectroscopy
NASA Astrophysics Data System (ADS)
Zhang, Yao; Markey, Mia K.; Tunnell, James W.
2017-02-01
Diffuse reflectance spectroscopy offers a noninvasive, fast, and low-cost alternative to visual screening and biopsy for skin cancer diagnosis. We have previously acquired reflectance spectra from 137 lesions in 76 patients and determined the capability of spectral diagnosis using principal component analysis (PCA). However, it is not well elucidated why spectral analysis enables tissue classification. To provide the physiological basis, we used the Monte Carlo look-up table (MCLUT) model to extract physiological parameters from those clinical data. The MCLUT model results in the following physiological parameters: oxygen saturation, hemoglobin concentration, melanin concentration, vessel radius, and scattering parameters. Physiological parameters show that cancerous skin tissue has lower scattering and larger vessel radii, compared to normal tissue. These results demonstrate the potential of diffuse reflectance spectroscopy for detection of early precancerous changes in tissue. In the future, a diagnostic algorithm that combines these physiological parameters could be enable non-invasive diagnosis of skin cancer.
USDA-ARS?s Scientific Manuscript database
Whole oat has been described as an important healthy food for humans due to its beneficial nutritional components. Near infrared reflectance spectroscopy (NIRS) is a powerful, fast, accurate and non-destructive analytical tool that can be substituted for some traditional chemical analysis. A total o...
Prediction of olive quality using FT-NIR spectroscopy in reflectance and transmittance modes
USDA-ARS?s Scientific Manuscript database
The objective of this research was to use FT-NIR spectroscopy to predict the firmness, oil content and color of two olive (Olea europaea L) varieties (‘Ayvalik’ and ‘Gemlik’). Spectral measurements were performed on the intact olives for the wavelengths of 780-2500 nm in reflectance and for 800-1725...
NASA Astrophysics Data System (ADS)
Liu, Wen; Zhang, Yuying; Yang, Si; Han, Donghai
2018-05-01
A new technique to identify the floral resources of honeys is demanded. Terahertz time-domain attenuated total reflection spectroscopy combined with chemometrics methods was applied to discriminate different categorizes (Medlar honey, Vitex honey, and Acacia honey). Principal component analysis (PCA), cluster analysis (CA) and partial least squares-discriminant analysis (PLS-DA) have been used to find information of the botanical origins of honeys. Spectral range also was discussed to increase the precision of PLS-DA model. The accuracy of 88.46% for validation set was obtained, using PLS-DA model in 0.5-1.5 THz. This work indicated terahertz time-domain attenuated total reflection spectroscopy was an available approach to evaluate the quality of honey rapidly.
Investigating Low-Cost Optical Spectroscopy for Sensing Pressure Ulcers
NASA Astrophysics Data System (ADS)
Mirchandani, Smruti Suresh
Diffuse Reflectance Spectroscopy has been used widely to characterize tissue properties for diagnostic and therapeutic applications. This thesis focuses on the use of spectroscopy for early pressure ulcer detection. The most common early diagnosis technique for pressure ulcers is a blanch test. A major issue with a blanch test is that it is purely visual and cannot be visibly observed on dark skinned individuals. Studies have already proven that spectroscopy can be used to detect blanch response in skin across light and dark skinned individuals. The portable reflectance spectroscopy setup showed that pressure changes to the skin can be detected spectroscopically. Some work on an iPhone based spectrometer was also done to have a low-cost spectroscopy alternative to the usual DRS equipment. This study failed to develop an iPhone based spectrometer but various factors that can be changed to better this research have been mentioned in this thesis.
Pancreatic tissue assessment using fluorescence and reflectance spectroscopy
NASA Astrophysics Data System (ADS)
Chandra, Malavika; Heidt, David; Simeone, Diane; McKenna, Barbara; Scheiman, James; Mycek, Mary-Ann
2007-07-01
The ability of multi-modal optical spectroscopy to detect signals from pancreatic tissue was demonstrated by studying human pancreatic cancer xenografts in mice and freshly excised human pancreatic tumor tissue. Measured optical spectra and fluorescence decays were correlated with tissue morphological and biochemical properties. The measured spectral features and decay times correlated well with expected pathological differences in normal, pancreatitis and adenocarcinoma tissue states. The observed differences between the fluorescence and reflectance properties of normal, pancreatitis and adenocarcinoma tissue indicate a possible application of multi-modal optical spectroscopy to differentiating between the three tissue classifications.
NASA Technical Reports Server (NTRS)
Siriwardane, R.; Wightman, J. P.
1980-01-01
The acid-base properties of titanium 6-4 plates (low surface area) were investigated after three different pretreatments, namely Turco, phosphate-fluoride and Pasa-Jell. A series of indicators was used and color changes were detected using diffuse reflectance visible spectroscopy. Electron spectroscopy for chemical analysis was used to examine the indicator on the Ti 6-4 surface. Specular reflectance infra-red spectroscopy was used to study the adsorption of stearic acid from cyclohexane solutions on the Ti 6-4 surface.
Identification of proteins in renaissance paintings by proteomics.
Tokarski, Caroline; Martin, Elisabeth; Rolando, Christian; Cren-Olivé, Cécile
2006-03-01
The presented work proposes a new methodology based on proteomics techniques to identify proteins in old art paintings. The main challenging tasks of this work were (i) to find appropriate conditions for extracting proteins from the binding media without protein hydrolysis in amino acids and (ii) to develop analytical methods adapted to the small sample quantity available. Starting from microsamples of painting models (ovalbumin-based, which is the major egg white protein, and egg-based paintings), multiple extraction solutions (HCl, HCOOH, NH3, NaOH) and conditions (ultrasonic bath, mortar and pestle, grinding resin) were evaluated. The best results were obtained using a commercial kit including a synthetic resin, mortar and pestle to grind the sample in an aqueous solution acidified with trifluoroacetic acid at 1% with additional multiple steps of ultrasonic baths. The resulting supernatant was analyzed by MALDI-TOF in linear mode to verify the efficiency of the extraction solution. An enzymatic hydrolysis step was also performed for protein identification; the peptide mixture was analyzed by nanoLC/nanoESI/Q-q-TOF MS/MS with an adapted chromatographic run for the low sample quantity. Finally, the developed methodology was successfully applied to Renaissance art painting microsamples of approximately 10 microg from Benedetto Bonfigli's triptych, The Virgin and Child, St. John the Baptist, St. Sebastian (XVth century), and Niccolo di Pietro Gerini's painting, The Virgin and Child (XIVth century), identifying, for the first time and without ambiguity, the presence of whole egg proteins (egg yolk and egg white) in a painting binder.
NASA Astrophysics Data System (ADS)
Stegehuis, Paulien L.; Boogerd, Leonora S. F.; Inderson, Akin; Veenendaal, Roeland A.; van Gerven, P.; Bonsing, Bert A.; Sven Mieog, J.; Amelink, Arjen; Veselic, Maud; Morreau, Hans; van de Velde, Cornelis J. H.; Lelieveldt, Boudewijn P. F.; Dijkstra, Jouke; Robinson, Dominic J.; Vahrmeijer, Alexander L.
2017-02-01
Endoscopic ultrasound-guided fine needle aspirations (EUS-FNA) of pancreatic masses suffer from sample errors and low-negative predictive values. Fiber-optic spectroscopy in the visible to near-infrared wavelength spectrum can noninvasively extract physiological parameters from tissue and has the potential to guide the sampling process and reduce sample errors. We assessed the feasibility of single fiber (SF) reflectance spectroscopy measurements during EUS-FNA of pancreatic masses and its ability to distinguish benign from malignant pancreatic tissue. A single optical fiber was placed inside a 19-gauge biopsy needle during EUS-FNA and at least three reflectance measurements were taken prior to FNA. Spectroscopy measurements did not cause any related adverse events and prolonged procedure time with ˜5 min. An accurate correlation between spectroscopy measurements and cytology could be made in nine patients (three benign and six malignant). The oxygen saturation and bilirubin concentration were significantly higher in benign tissue compared with malignant tissue (55% versus 21%, p=0.038; 166 μmol/L versus 17 μmol/L, p=0.039, respectively). To conclude, incorporation of SF spectroscopy during EUS-FNA was feasible, safe, and relatively quick to perform. The optical properties of benign and malignant pancreatic tissue are different, implying that SF spectroscopy can potentially guide the FNA sampling.
USDA-ARS?s Scientific Manuscript database
Background: Skin carotenoid status, as assessed by reflection spectroscopy (RS), is a promising means of approximating fruit and vegetable consumption. This study’s purpose was to assess the feasibility, reliability, and validity of RS to assess skin carotenoids in a racially diverse community sampl...
Surface layering and melting in an ionic liquid studied by resonant soft X-ray reflectivity
Mezger, Markus; Ocko, Benjamin M.; Reichert, Harald; Deutsch, Moshe
2013-01-01
The molecular-scale structure of the ionic liquid [C18mim]+[FAP]− near its free surface was studied by complementary methods. X-ray absorption spectroscopy and resonant soft X-ray reflectivity revealed a depth-decaying near-surface layering. Element-specific interfacial profiles were extracted with submolecular resolution from energy-dependent soft X-ray reflectivity data. Temperature-dependent hard X-ray reflectivity, small- and wide-angle X-ray scattering, and infrared spectroscopy uncovered an intriguing melting mechanism for the layered region, where alkyl chain melting drove a negative thermal expansion of the surface layer spacing. PMID:23431181
Multimodal fiber-probe spectroscopy for the diagnostics and classification of bladder tumors
NASA Astrophysics Data System (ADS)
Anand, Suresh; Cicchi, Riccardo; Fantechi, Riccardo; Gacci, Mauro; Nesi, Gabriella; Carini, Marco; Pavone, Francesco S.
2017-02-01
The gold standard for the detection of bladder cancer is white light cystoscopy, followed by an invasive biopsy and pathological examination. Tissue pathology is time consuming and often prone to sampling errors. Recently, optical spectroscopy techniques have evolved as promising techniques for the detection of neoplasia. The specific goal of this study is to evaluate the application of combined auto-fluorescence (excited using 378 nm and 445 nm wavelengths) and diffuse reflectance spectroscopy to discriminate normal bladder tissue from tumor at different grades. The fluorescence spectrum at both excitation wavelengths showed an increased spectral intensity in tumors with respect to normal tissues. Reflectance data indicated an increased reflectance in the wavelength range 610 nm - 700 nm for different grades of tumors, compared to normal tissues. The spectral data were further analyzed using principal component analysis for evaluating the sensitivity and specificity for diagnosing tumor. The spectral differences observed between various grades of tumors provides a strong genesis for the future evaluation on a larger patient population to achieve statistical significance. This study indicates that a combined spectroscopic strategy, incorporating fluorescence and reflectance spectroscopy, could improve the capability for diagnosing bladder tumor as well as for differentiating tumors in different grades.
NASA Astrophysics Data System (ADS)
Wegmann, M. I.; Hammerschmidt, K.
2003-12-01
Retrograde overprinted calcite-bearing micaschists and mica-containing marbles from the northern part of the Cycladic blueschist belt on South-Evia, Greece, have been investigated to understand the interplay between bulk rock chemistry, mineral assemblage and resetting of the Rb-Sr isotope system during deformation. White mica represents two optical distinguishable microstructures, isoclinal folds (S1) and axial plain cleavage (S2) induced by flattening and elongation episode of isothermal exhumation. The varying Si content of phengites is not related to microstructures. Due to microstructural complexity and grain size variation the application of Rb-Sr microsampling method was expected effective investigation of Rb and Sr rich mineral phases to elucidate constraints for geochronological and isotope geochemical imprint in microstructures. Drilling out calcite, albite and mica samples with weights down to 200æg each out of 30æm thick sections realized textural controlled separation. Calculated Rb-Sr mica ages show lithology-related scattering but totally not microstructural induced variation. Particulary, S1 and S2 phengites in micaschist yield similar age values around 31 Ma. In contrast, impure marble mica within similar S1 and S2 have Rb-Sr mica ages widely scattering between 34 and 50 Ma. Therefore, structural elements formed by these phengites are not distinguishable in terms of geochronolgy. Explaining the scatter of age values, principally, two possibilities were taken into account, (i) the fluid flux neccessary to homogenize Sr isotope composition in mica and calcite (albite) might have been less effective in impure marble than in micaschist due to the generation of CO2. In constrast to this possibility, calcite 87Sr/86Sr in both specimen are quite homogeneous at least on cm-scale, e.g. values of 0.712125 ñ 66 (2s) for impure marble and of 0.721419 ñ 42 for micaschist were meassured. Albite 87Sr/86Sr corroborate Sr homogenisation on scale this study was focussed on. So far, (ii) we would assume calculated age values date moments of growth of single mica crystals. However, the image of microstructure by crystals may be realized by new growth, recrystallization or just reorientation, e.g. by passive rotation of pre-existing grains. To interpret the mineral age values, it must be scrutinized, which process is responsible for current mineral position in the structure. Additionally, duration of (prograde) exumation induced contineous deformation and the contribution of fluid influx can be prospected by further investigation of south-Evian blueschist facies units on other mineral phases by Rb-Sr microsampling technique.
Weagant, Scott; Chen, Vivian; Karanassios, Vassili
2011-11-01
A battery-operated, atmospheric pressure, self-igniting, planar geometry Ar-H(2) microplasma for elemental analysis of liquid microsamples is described. The inexpensive microplasma device (MPD) fabricated for this work was a hybrid plastic-quartz structure that was formed on chips with an area (roughly) equal to that of a small-sized postage stamp (MPD footprint, 12.5-mm width by 38-mm length). Plastic substrates were chosen due to their low cost, for rapid prototyping purposes, and for a speedy microplasma device evaluation. To enhance portability, the microplasma was operated from an 18-V rechargeable battery. To facilitate portability even further, it was demonstrated that the battery can be recharged by a portable solar panel. The battery-supplied dc voltage was converted to a high-voltage ac. The ~750-μm (diameter) and 12-mm (long) Ar-H(2) (3% H(2)) microplasma was formed by applying the high-voltage ac between two needle electrodes. Spectral interference from the electrode materials or from the plastic substrate was not observed. Operating conditions were found to be key to igniting and sustaining a microplasma that was simply "warm" to the touch (thus alleviating the need for cooling or other thermal management) and that had a stable background emission. A small-sized (900 μL internal volume) electrothermal vaporization system (40-W max power) was used for microsample introduction. Microplasma background emission in the spectral region between 200 and 850 nm obtained using a portable fiber-optic spectrometer is reported and the effect of the operating conditions is described. Analyte emission from microliter volumes of dilute single-element standard solutions of Cd, Cu, K, Li, Mg, Mn, Na, Pb, and Zn is documented. The majority of spectral lines observed for the elements tested were from neutral atoms. The relative lack of emission from ion lines simplified the spectra, thus facilitating the use of a portable spectrometer. Despite the relative spectral simplicity, some spectral interference effects were noted when running a multi-element solution. An example of how interference in the spectral domain can be resolved in the time domain using selective thermal vaporization is provided. Analytical utility and performance characteristics are reported; for example, K concentrations in diluted (~30 times) bottled water were determined to be 4.1 ± 1.0 μg/mL (4 μg/mL was the stated concentration), precision was about 25%, and the estimated detection limits were in the picogram range (or in nanograms per milliliter in relative units).
NASA Astrophysics Data System (ADS)
Brigaud, Benjamin; Pucéat, Emmanuelle; Pellenard, Pierre; Vincent, Benoît; Joachimski, Michael M.
2008-08-01
Oxygen isotope data from biostratigraphically well-dated oyster shells from the Late Jurassic of the eastern Paris Basin are used to reconstruct the thermal evolution of western Tethyan surface waters during the Early Oxfordian-Early Kimmeridgian interval. Seventy eight oyster shells were carefully screened for potential diagenetic alteration using cathodoluminescence microscopy. Isotope analyses were performed on non-luminescent parts of shells (n = 264). Intra-shell δ18O variability was estimated by microsampling along a transect perpendicular to the growth lines of the largest oyster shell. The sinusoidal distribution of the δ18O values along this transect and the dependence of the amplitude of variations with bathymetry suggest that intra-shell variability reflects seasonal variations of temperature and/or salinity. Average amplitudes of about 5 °C in shallow water environments and of about 2-3 °C in deeper offshore environments are calculated. These amplitudes reflect minimum seasonal temperature variation. Our new data allow to constrain existing paleotemperature trends established from fish tooth and belemnite δ18O data and are in better agreement with paleontological data. More specifically, a warming trend of about 3 °C is reconstructed for oceanic surface waters during the Early to Middle Oxfordian transition, with maximum temperatures reaching 24 °C in the transversarium Zone (late Middle Oxfordian). From the transversarium Zone to the bimmamatum Zone, a cooling of about 7 °C is indicated, whereas from the bimmamatum Zone, temperatures increased again by about 7 °C to reach 24 °C in average during the cymodoce Zone (Early Kimmeridgian).
Invernizzi, Claudia; Daveri, Alessia; Vagnini, Manuela; Malagodi, Marco
2017-05-01
The analysis of historical musical instruments is becoming more relevant and the interest is increasingly moving toward the non-invasive reflection FTIR spectroscopy, especially for the analysis of varnishes. In this work, a specific infrared reflectance spectral library of organic compounds was created with the aim of identifying musical instrument materials in a totally non-invasive way. The analyses were carried out on pure organic compounds, as bulk samples and laboratory wooden models, to evaluate the diagnostic reflection mid-infrared (MIR) bands of proteins, polysaccharides, lipids, and resins by comparing reflection spectra before and after the KK correction. This methodological approach was applied to real case studies represented by four Stradivari violins and a Neapolitan mandolin.
NASA Astrophysics Data System (ADS)
Proehl, Holger; Nitsche, Robert; Dienel, Thomas; Leo, Karl; Fritz, Torsten
2005-04-01
We report an investigation of the excitonic properties of thin crystalline films of the archetypal organic semiconductor PTCDA (3,4,9,10-perylenetetracarboxylic dianhydride) grown on poly- and single crystalline surfaces. A sensitive setup capable of measuring the optical properties of ultrathin organic molecular crystals via differential reflectance spectroscopy (DRS) is presented. This tool allows to carry out measurements in situ, i.e., during the actual film growth, and over a wide spectral range, even on single crystalline surfaces with high symmetry or metallic surfaces, where widely used techniques like reflection anisotropy spectroscopy (RAS) or fluorescence excitation spectroscopy fail. The spectra obtained by DRS resemble mainly the absorption of the films if transparent substrates are used, which simplifies the analysis. In the case of mono- to multilayer films of PTCDA on single crystalline muscovite mica(0001) and Au(111) substrates, the formation of the solid state absorption from monomer to dimer and further to crystal-like absorption spectra can be monitored.
Calculation and Study of Graphene Conductivity Based on Terahertz Spectroscopy
NASA Astrophysics Data System (ADS)
Feng, Xiaodong; Hu, Min; Zhou, Jun; Liu, Shenggang
2017-07-01
Based on terahertz time-domain spectroscopy system and two-dimensional scanning control system, terahertz transmission and reflection intensity mapping images on a graphene film are obtained, respectively. Then, graphene conductivity mapping images in the frequency range 0.5 to 2.5 THz are acquired according to the calculation formula. The conductivity of graphene at some typical regions is fitted by Drude-Smith formula to quantitatively compare the transmission and reflection measurements. The results show that terahertz reflection spectroscopy has a higher signal-to-noise ratio with less interference of impurities on the back of substrates. The effect of a red laser excitation on the graphene conductivity by terahertz time-domain transmission spectroscopy is also studied. The results show that the graphene conductivity in the excitation region is enhanced while that in the adjacent area is weakened which indicates carriers transport in graphene under laser excitation. This paper can make great contribution to the study on graphene electrical and optical properties in the terahertz regime and help design graphene terahertz devices.
Oxidation-Resistant Surfaces For Solar Reflectors
NASA Technical Reports Server (NTRS)
Gulino, Daniel A.; Egger, Robert A.; Banholzer, William F.
1988-01-01
Thin films on silver provide highly-reflective, corrosion-resistant mirrors. Study evaluated variety of oxidation-resistant reflective materials for use in solar dynamic power system, one that generates electricity by focusing Sunlight onto reciever of heat engine. Thin films of platinum and rhodium deposited by ion-beam sputtering on various substrate materials. Solar reflectances measured as function of time of exposure to radio-frequency-generated air plasma. Several protective coating materials deposited on silver-coated substrates and exposed to plasma. Analyzed before and after exposure by electon spectroscopy for chemical analysis and by Auger spectroscopy.
Ershova, N I; Ivanov, V M
2000-05-01
Cellulose and chromaton-N-super as solid supports for direct determination of the immobilized nickel complexes with dimethylglyoxime and benzyldioxime by diffuse reflection spectroscopy were compared. The advantage of chromaton-N-super with use of benzyldioxime is shown. Detection limit is 0.02 microg/mL. The proposed method was applied for the analysis of soil.
USDA-ARS?s Scientific Manuscript database
This study assessed the feasibility, reliability and validity of reflection spectroscopy (RS) to assess skin carotenoids in a racially diverse sample. Study 1 was a cross-sectional study of corner store customers (n= 479) in Eastern North Carolina USA who completed the National Cancer Institute Frui...
Soil profile property estimation with field and laboratory VNIR spectroscopy
USDA-ARS?s Scientific Manuscript database
Diffuse reflectance spectroscopy (DRS) soil sensors have the potential to provide rapid, high-resolution estimation of multiple soil properties. Although many studies have focused on laboratory-based visible and near-infrared (VNIR) spectroscopy of dried soil samples, previous work has demonstrated ...
Deng, Jian-qiang; Hou, Yi-ping
2005-08-01
Genetic analysis from forensic microsamples is a urgent, difficult task in forensic science, because it is frequently limited by the amount of specimen available in forensic practice, much effort has been carried out to resolve this difficulty. Whole genome amplification (WGA) technology, which was developing quickly in these years, has been thought to be a powerful, reliable and efficient strategy in analysis of minute amount DNA on many fields. In this review, we discuss its application in forensic science.
Dunlop, Iain E.; Zorn, Stefan; Richter, Gunther; Srot, Vesna; Kelsch, Marion; van Aken, Peter A.; Skoda, Maximilian; Gerlach, Alexander; Spatz, Joachim P.; Schreiber, Frank
2010-01-01
We present a titanium-silicon oxide film structure that permits polarization modulated infrared reflection absorption spectroscopy on silicon oxide surfaces. The structure consists of a ~6 nm sputtered silicon oxide film on a ~200 nm sputtered titanium film. Characterization using conventional and scanning transmission electron microscopy, electron energy loss spectroscopy, X-ray photoelectron spectroscopy and X-ray reflectometry is presented. We demonstrate the use of this structure to investigate a selectively protein-resistant self-assembled monolayer (SAM) consisting of silane-anchored, biotin-terminated poly(ethylene glycol) (PEG). PEG-associated IR bands were observed. Measurements of protein-characteristic band intensities showed that this SAM adsorbed streptavidin whereas it repelled bovine serum albumin, as had been expected from its structure. PMID:20418963
NASA Astrophysics Data System (ADS)
Duarte Cavalcante, Luis Carlos; Ferraro, Lorena; Hugon, Paulette; Soares Meneses Lage, Maria Conceição; Fabris, José Domingos
2017-11-01
The archaeological site Manantial Solís is located on shores of the Cardiel Lake, Santa Cruz Province, Patagonia, Argentina. The main characteristic of this site is the occurrence of 251 rupestrian paintings, namely abstract figures, anthropomorphic and zoomorphic motifs, painted in different hues of red, but also in yellow, orange, pink, violet and white; these paintings are often formed by overlapping pictorial motifs. The basaltic rock-wall supporting these graphisms has been naturally degraded and, as a consequence, covered with saline efflorescence. The chemical and mineralogical analyses of a micro-sample from a red rupestrian painting were made in the laboratory by (i) energy dispersive X-ray fluorescence; (ii) CHN elemental analysis and (iii) 57Fe transmission Mössbauer spectroscopy at 298 K and 110 K, in an effort to identify the main iron-bearing minerals composing the painting pigments. The stratigraphy of the paint layer was investigated on a polished cross-section. From the Mössbauer spectra of this red painting, two sextets assignable to hematite ( α Fe2O3) were identified. The Fe3+ central doublet is assumed to be due to superparamagnetic phases, more likely as iron (oxyhydr)oxides (likely including some goethite, α FeOOH) in very small particles and paramagnetic iron in the crystalline structure of aluminosilicates. The Fe2+ doublet was interpreted as being due to the basalt rock support of this prehistoric painting.
NASA Astrophysics Data System (ADS)
Arantes Camargo, Livia; Marques Júnior, José; Reynaldo Ferracciú Alleoni, Luís; Tadeu Pereira, Gener; De Bortoli Teixeira, Daniel; Santos Rabelo de Souza Bahia, Angélica
2017-04-01
Environmental impact assessments may be assisted by spatial characterization of potentially toxic elements (PTEs). Diffuse reflectance spectroscopy (DRS) and X-ray fluorescence spectroscopy (XRF) are rapid, non-destructive, low-cost, prediction tools for a simultaneous characterization of different soil attributes. Although low concentrations of PTEs might preclude the observation of spectral features, their contents can be predicted using spectroscopy by exploring the existing relationship between the PTEs and soil attributes with spectral features. This study aimed to evaluate, in three geomorphic surfaces of Oxisols, the capacity for predicting PTEs (Ba, Co, and Ni) and their spatial variability by means of diffuse reflectance spectroscopy (DRS) and X-ray fluorescence spectroscopy (XRF). For that, soil samples were collected from three geomorphic surfaces and analyzed for chemical, physical, and mineralogical properties, and then analyzed in DRS (visible + near infrared - VIS+NIR and medium infrared - MIR) and XRF equipment. PTE prediction models were calibrated using partial least squares regression (PLSR). PTE spatial distribution maps were built using the values calculated by the calibrated models that reached the best accuracy using geostatistics. PTE prediction models were satisfactorily calibrated using MIR DRS for Ba, and Co (residual prediction deviation - RPD > 3.0), Vis DRS for Ni (RPD > 2.0) and FRX for all the studied PTEs (RPD > 1.8). DRS- and XRF-predicted values allowed the characterization and the understanding of spatial variability of the studied PTEs.
Estimation of soil profile properties using field and laboratory VNIR spectroscopy
USDA-ARS?s Scientific Manuscript database
Diffuse reflectance spectroscopy (DRS) soil sensors have the potential to provide rapid, high-resolution estimation of multiple soil properties. Although many studies have focused on laboratory-based visible and near-infrared (VNIR) spectroscopy of dried soil samples, previous work has demonstrated ...
NASA Astrophysics Data System (ADS)
Maeter, H.; Briese, V.; Gerber, B.; Darvin, M. E.; Lademann, J.; Olbertz, D. M.
2013-10-01
Laser spectroscopic methods, for instance resonance Raman spectroscopy and reflectance spectroscopy, permit us for the first time to investigate the antioxidative status in human skin non-invasively by measurement of carotenoid concentration. The individual antioxidant concentration of the human skin is determined by the nutritional habits, on the one hand, and by stressors, such as shift work, on the other. Due to the disturbance of the circadian rhythm and melatonin secretion, shift work is associated with, inter alia, insomnia and gastrointestinal disorders. The study at hand was the first to determine the cutaneous antioxidant concentration of midwives using reflectance spectroscopy and to relate the results to shift work. Seven midwives took part in the study. An LED-based compact scanner system was used for non-invasive measurements of carotenoids in human skin. The measuring principle is based on reflection spectroscopy. The study at hand suggests that the cutaneous antioxidative status may be adversely affected by shift work. Despite numerous international strategies of programmes available which invite people to eat more healthily, there are only a few measures aiming at stress reduction and management. In this field the use of reflectance spectroscopic investigation methods could play an essential role in the future.
Quantitative reflectance spectroscopy of buddingtonite from the Cuprite mining district, Nevada
NASA Technical Reports Server (NTRS)
Felzer, Benjamin; Hauff, Phoebe; Goetz, Alexander F. H.
1994-01-01
Buddingtonite, an ammonium-bearing feldspar diagnostic of volcanic-hosted alteration, can be identified and, in some cases, quantitatively measured using short-wave infrared (SWIR) reflectance spectroscopy. In this study over 200 samples from Cuprite, Nevada, were evaluated by X ray diffraction, chemical analysis, scanning electron microscopy, and SWIR reflectance spectroscopy with the objective of developing a quantitative remote-sensing technique for rapid determination of the amount of ammonium or buddingtonite present, and its distribution across the site. Based upon the Hapke theory of radiative transfer from particulate surfaces, spectra from quantitative, physical mixtures were compared with computed mixture spectra. We hypothesized that the concentration of ammonium in each sample is related to the size and shape of the ammonium absorption bands and tested this hypothesis for samples of relatively pure buddingtonite. We found that the band depth of the 2.12-micron NH4 feature is linearly related to the NH4 concentration for the Cuprite buddingtonite, and that the relationship is approximately exponential for a larger range of NH4 concentrations. Associated minerals such as smectite and jarosite suppress the depth of the 2.12-micron NH4 absorption band. Quantitative reflectance spectroscopy is possible when the effects of these associated minerals are also considered.
ERIC Educational Resources Information Center
Chemical and Engineering News, 1979
1979-01-01
Surveys the state of commerical development of analytical instrumentation as reflected by the Pittsburgh Conference on Analytical Chemistry and Applied Spectroscopy. Includes optical spectroscopy, liquid chromatography, magnetic spectrometers, and x-ray. (Author/MA)
Specular Reflection and Diffuse Reflectance Spectroscopy of Soils
USDA-ARS?s Scientific Manuscript database
Studies on the occurrence and effects of specular reflection in mid-infrared spectra of soils have shown that distortions due to specular reflection occur for both organic (humic acid) and non-organic fractions (carbonates, silica, ashed fraction of soil). The results demonstrated explain why the s...
NASA Astrophysics Data System (ADS)
Narita, Katsutoshi; Hijikata, Yasuto; Yaguchi, Hiroyuki; Yoshida, Sadafumi; Nakashima, Shinichi
2004-08-01
We have estimated the free-carrier concentration and drift mobility in n-type 6H-SiC wafers in the carrier concentration range of 1017-1019 cm-3 from far- and mid-infrared (30-2000 cm-1) reflectance spectra obtained at room temperature. A modified classical dielectric function model was employed for the analysis. We found good agreement between the electrical properties derived from infrared reflectance spectroscopy and those derived from Hall effect measurements. We have demonstrated the spatial mapping of carrier concentration and mobility for commercially produced 2 inch SiC wafers.
In situ temperature measurement of. alpha. -mercuric iodide by reflection spectroscopy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nason, D.; Burger, A.
1991-12-30
Crystal face temperatures of single crystals of {alpha}-HgI{sub 2} growing in transparent ampules by physical vapor transport have been measured, {ital in} {ital situ}, by a novel, noncontact method which may be called reflectance spectroscopy thermometry. The method is based on the temperature dependence of the energy of the free-exciton peak as detected with a low-energy reflected beam. As presently configured, the accuracy is {plus minus}1.5 {degree}C for a slowly varying surface temperature. The method has potential for noncontact temperature measurement in some systems for which pyrometry is unsatisfactory.
NASA Astrophysics Data System (ADS)
Oh, Sanghoon; Ragheb, John; Bhatia, Sanjiv; Sandberg, David; Johnson, Mahlon; Fernald, Bradley; Lin, Wei-Chiang
2008-02-01
Optical spectroscopy for in vivo tissue diagnosis is performed traditionally in a static manner; a snap shot of the tissue biochemical and morphological characteristics is captured through the interaction between light and the tissue. This approach does not capture the dynamic nature of a living organ, which is critical to the studies of brain disorders such as epilepsy. Therefore, a time-dependent diffuse reflectance spectroscopy system with a fiber-optic probe was designed and developed. The system was designed to acquire broadband diffuse reflectance spectra (240 ~ 932 nm) at an acquisition rate of 33 Hz. The broadband spectral acquisition feature allows simultaneous monitoring of various physiological characteristics of tissues. The utility of such a system in guiding pediatric epilepsy surgery was tested in a pilot clinical study including 13 epilepsy patients and seven brain tumor patients. The control patients were children undergoing suregery for brain tumors in which measurements were taken from normal brain exposed during the surgery. Diffuse reflectance spectra were acquired for 12 seconds from various parts of the brain of the patients during surgery. Recorded spectra were processed and analyzed in both spectral and time domains to gain insights into the dynamic changes in, for example, hemodynamics of the investigated brain tissue. One finding from this pilot study is that unsynchronized alterations in local blood oxygenation and local blood volume were observed in epileptogenic cortex. These study results suggest the advantage of using a time-dependent diffuse reflectance spectroscopy system to study epileptogenic brain in vivo.
Lim, Jongguk; Kim, Giyoung; Mo, Changyeun; Oh, Kyoungmin; Kim, Geonseob; Ham, Hyeonheui; Kim, Seongmin; Kim, Moon S.
2018-01-01
Fusarium is a common fungal disease in grains that reduces the yield of barley and wheat. In this study, a near infrared reflectance spectroscopic technique was used with a statistical prediction model to rapidly and non-destructively discriminate grain samples contaminated with Fusarium. Reflectance spectra were acquired from hulled barley, naked barley, and wheat samples contaminated with Fusarium using near infrared reflectance (NIR) spectroscopy with a wavelength range of 1175–2170 nm. After measurement, the samples were cultured in a medium to discriminate contaminated samples. A partial least square discrimination analysis (PLS-DA) prediction model was developed using the acquired reflectance spectra and the culture results. The correct classification rate (CCR) of Fusarium for the hulled barley, naked barley, and wheat samples developed using raw spectra was 98% or higher. The accuracy of discrimination prediction improved when second and third-order derivative pretreatments were applied. The grains contaminated with Fusarium could be rapidly discriminated using spectroscopy technology and a PLS-DA discrimination model, and the potential of the non-destructive discrimination method could be verified. PMID:29301319
Re-evaluation of model-based light-scattering spectroscopy for tissue spectroscopy
Lau, Condon; Šćepanović, Obrad; Mirkovic, Jelena; McGee, Sasha; Yu, Chung-Chieh; Fulghum, Stephen; Wallace, Michael; Tunnell, James; Bechtel, Kate; Feld, Michael
2009-01-01
Model-based light scattering spectroscopy (LSS) seemed a promising technique for in-vivo diagnosis of dysplasia in multiple organs. In the studies, the residual spectrum, the difference between the observed and modeled diffuse reflectance spectra, was attributed to single elastic light scattering from epithelial nuclei, and diagnostic information due to nuclear changes was extracted from it. We show that this picture is incorrect. The actual single scattering signal arising from epithelial nuclei is much smaller than the previously computed residual spectrum, and does not have the wavelength dependence characteristic of Mie scattering. Rather, the residual spectrum largely arises from assuming a uniform hemoglobin distribution. In fact, hemoglobin is packaged in blood vessels, which alters the reflectance. When we include vessel packaging, which accounts for an inhomogeneous hemoglobin distribution, in the diffuse reflectance model, the reflectance is modeled more accurately, greatly reducing the amplitude of the residual spectrum. These findings are verified via numerical estimates based on light propagation and Mie theory, tissue phantom experiments, and analysis of published data measured from Barrett’s esophagus. In future studies, vessel packaging should be included in the model of diffuse reflectance and use of model-based LSS should be discontinued. PMID:19405760
NASA Astrophysics Data System (ADS)
Lim, Hoong-Ta; Murukeshan, Vadakke Matham
2017-01-01
Photoacoustic spectroscopy has been used to measure optical absorption coefficient and the application of tens of wavelength bands in photoacoustic spectroscopy was reported. Using optical methods, absorption-related information is, generally, derived from reflectance or transmittance values. Hence measurement accuracy is limited for highly absorbing samples where the reflectance or transmittance is too low to give reasonable signal-to-noise ratio. In this context, this paper proposes and illustrates a hyperspectral photoacoustic spectroscopy system to measure the absorption-related properties of highly absorbing samples directly. The normalized optical absorption coefficient spectrum of the highly absorbing iris is acquired using an optical absorption coefficient standard. The proposed concepts and the feasibility of the developed diagnostic medical imaging system are demonstrated using fluorescent microsphere suspensions and porcine eyes as test samples.
Godinho, Bruno M D C; Gilbert, James W; Haraszti, Reka A; Coles, Andrew H; Biscans, Annabelle; Roux, Loic; Nikan, Mehran; Echeverria, Dimas; Hassler, Matthew; Khvorova, Anastasia
2017-12-01
Therapeutic oligonucleotides, such as small interfering RNAs (siRNAs), hold great promise for the treatment of incurable genetically defined disorders by targeting cognate toxic gene products for degradation. To achieve meaningful tissue distribution and efficacy in vivo, siRNAs must be conjugated or formulated. Clear understanding of the pharmacokinetic (PK)/pharmacodynamic behavior of these compounds is necessary to optimize and characterize the performance of therapeutic oligonucleotides in vivo. In this study, we describe a simple and reproducible methodology for the evaluation of in vivo blood/plasma PK profiles and tissue distribution of oligonucleotides. The method is based on serial blood microsampling from the saphenous vein, coupled to peptide nucleic acid hybridization assay for quantification of guide strands. Performed with minimal number of animals, this method allowed unequivocal detection and sensitive quantification without the need for amplification, or further modification of the oligonucleotides. Using this methodology, we compared plasma clearances and tissue distribution profiles of two different hydrophobically modified siRNAs (hsiRNAs). Notably, cholesterol-hsiRNA presented slow plasma clearances and mainly accumulated in the liver, whereas, phosphocholine-docosahexaenoic acid-hsiRNA was rapidly cleared from the plasma and preferably accumulated in the kidney. These data suggest that the PK/biodistribution profiles of modified hsiRNAs are determined by the chemical nature of the conjugate. Importantly, the method described in this study constitutes a simple platform to conduct pilot assessments of the basic clearance and tissue distribution profiles, which can be broadly applied for evaluation of new chemical variants of siRNAs and micro-RNAs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ikonomou, M.G.; Crewe, N.F.; Fischer, M.
It has been demonstrated that marine mammals accumulate high concentrations of lipophilic organochlorine contaminants in blubber. As predators of the high trophic level they have also been used to evaluate contamination in the marine environment. Sampling of living marine mammals using a microsample (100 to 200 mg) biopsy dart technique offers a potentially invaluable chronicle in assessing levels and types of persistent environmental pollutants from a sample in which age, sex and other genetic information can additionally be ascertained. The authors have explored analytical methodology based on a high sensitivity detection system (HRGC/HRMS) which provides multi-residue determinations from biopsy dartmore » microsamples. Lipid content and the concentrations of PCDDs, PCDFs and non-ortho and mono-ortho substituted PCBs were measured in 100 mg biopsy dart replicates taken from a killer whale carcass and in three strata of the blubber of that carcass. Statistically acceptable results were obtained from the dart replicates which compared very well with those of the blubber strata. Analytical data from 100 mg extractions from an established in house blubber CRM also compared well against a series of 2.5 g extractions of that CRM. The extraction and cleanup procedures used also allow for the determination of other organohalogen contaminants such as DDT and other pesticides, all the remaining PCBs, polychlorinated diphenylethers and brominated residues. The strengths and limitations of the analytical methodology and the biopsy dart as a sampling tool and pollution predicator will be illustrated in terms of method accuracy and precision, glassware and procedural blanks associated with each extraction batch, and the incorporation of an in house micro reference standard.« less
Borovkova, Mariia; Khodzitsky, Mikhail; Demchenko, Petr; Cherkasova, Olga; Popov, Alexey; Meglinski, Igor
2018-05-01
We apply terahertz time-domain spectroscopy for the quantitative non-invasive assessment of the water content in biological samples, such as Carpinus caroliniana tree leaves and pork muscles. The developed experimental terahertz time-domain spectroscopy system operates both in transmission and reflection modes. The Landau-Looyenga-Lifshitz-based model is used for the calculation of the water concentration within the samples. The results of the water concentration measurements are compared with the results of the gravimetric measurements. The obtained results show that the water content in biological samples can be measured non-invasively, with a high accuracy, utilizing terahertz waves in transmission and reflection modes.
USDA-ARS?s Scientific Manuscript database
Detection of individual wheat kernels with black tip symptom (BTS) and black tip damage (BTD) was demonstrated using near infrared reflectance spectroscopy (NIRS) and silicon light-emitting-diode (LED) based instruments. The two instruments tested, a single kernel near-infrared spectroscopy instrume...
NASA Astrophysics Data System (ADS)
Azmy, Karem; Stouge, Svend; Christiansen, Jørgen L.; Harper, Dave A. T.; Knight, Ian; Boyce, Douglas
2010-03-01
The Lower Ordovician sequence on the Ella Ø Island in Northeast (N-E) Greenland is a thick shallow marine platform carbonate sequence (˜ 1415 m thick) and constitutes the major part of the Kong Oscar Fjord Group. It consists, from bottom to top, of the Antiklinalbugt, Septembersø, and Cape Weber formations, which are believed to be respectively coeval with the Watts Bight, Boat Harbour, and Catoche formations of the St. George Group in western Newfoundland, Canada. Samples were collected from outcrops at high-resolution intervals and micritic materials were extracted by microdrilling after screening their petrographic and geochemical criteria to evaluate the degree of preservation. The δ13C and δ18O values of well preserved micrite microsamples range from -5.2‰ to 0.5‰ (VPDB) and from -10.3‰ to-6.5‰ (VPDB), respectively. The δ13C carb profile of the sequence reveals few negative shifts, which vary between ˜ 2 and 4.7‰ and are associated with unconformities/disconformities, thus reflecting the effect of significant sea-level changes. The δ13C shifts can be correlated with counterparts on the St. George Group and also on the global Lower Ordovician δ13C profiles around the early Tremadoc (˜ 2.3‰) and late Tremadoc-early Arenig (˜ 4.7‰).
NASA Astrophysics Data System (ADS)
Zam, Azhar; Stelzle, Florian; Tangermann-Gerk, Katja; Adler, Werner; Nkenke, Emeka; Schmidt, Michael; Douplik, Alexandre
2010-02-01
Remote laser surgery lacks of haptic feedback during the laser ablation of tissue. Hence, there is a risk of iatrogenic damage or destruction of anatomical structures like nerves or salivary glands. Diffuse reflectance spectroscopy provides a straightforward and simple approach for optical tissue differentiation. We measured diffuse reflectance from seven various tissue types ex vivo. We applied Linear Discriminant Analysis (LDA) to differentiate the seven tissue types and computed the area under the ROC curve (AUC). Special emphasis was taken on the identification of nerves and salivary glands as the most crucial tissue for maxillofacial surgery. The results show a promise for differentiating tissues as guidance for oral and maxillofacial laser surgery by means of diffuse reflectance.
Cartilage analysis by reflection spectroscopy
NASA Astrophysics Data System (ADS)
Laun, T.; Muenzer, M.; Wenzel, U.; Princz, S.; Hessling, M.
2015-07-01
A cartilage bioreactor with analytical functions for cartilage quality monitoring is being developed. For determining cartilage composition, reflection spectroscopy in the visible (VIS) and near infrared (NIR) spectral region is evaluated. Main goal is the determination of the most abundant cartilage compounds water, collagen I and collagen II. Therefore VIS and NIR reflection spectra of different cartilage samples of cow, pig and lamb are recorded. Due to missing analytical instrumentation for identifying the cartilage composition of these samples, typical literature concentration values are used for the development of chemometric models. In spite of these limitations the chemometric models provide good cross correlation results for the prediction of collagen I and II and water concentration based on the visible and the NIR reflection spectra.
Kino, Saiko; Omori, Suguru; Katagiri, Takashi; Matsuura, Yuji
2016-02-01
A mid-infrared attenuated total reflection (ATR) spectroscopy system employing hollow optical fibers and a trapezoidal multi-reflection ATR prism has been developed to measure blood glucose levels. Using a multi-reflection prism brought about higher sensitivity, and the flat and wide contact surface of the prism resulted in higher measurement reproducibility. An analysis of in vivo measurements of human inner lip mucosa revealed clear signatures of glucose in the difference spectra between ones taken during the fasting state and ones taken after ingestion of glucose solutions. A calibration plot based on the absorption peak at 1155 cm(-1) that originates from the pyranose ring structure of glucose gave measurement errors less than 20%.
Depth-resolved measurements with elliptically polarized reflectance spectroscopy
Bailey, Maria J.; Sokolov, Konstantin
2016-01-01
The ability of elliptical polarized reflectance spectroscopy (EPRS) to detect spectroscopic alterations in tissue mimicking phantoms and in biological tissue in situ is demonstrated. It is shown that there is a linear relationship between light penetration depth and ellipticity. This dependence is used to demonstrate the feasibility of a depth-resolved spectroscopic imaging using EPRS. The advantages and drawbacks of EPRS in evaluation of biological tissue are analyzed and discussed. PMID:27446712
NASA Astrophysics Data System (ADS)
Mabilangan, Arvin I.; Lopez, Lorenzo P.; Faustino, Maria Angela B.; Muldera, Joselito E.; Cabello, Neil Irvin F.; Estacio, Elmer S.; Salvador, Arnel A.; Somintac, Armando S.
2016-12-01
Porosity dependent terahertz emission of porous silicon (PSi) was studied. The PSi samples were fabricated via electrochemical etching of boron-doped (100) silicon in a solution containing 48% hydrofluoric acid, deionized water and absolute ethanol in a 1:3:4 volumetric ratio. The porosity was controlled by varying the supplied anodic current for each sample. The samples were then optically characterized via normal incidence reflectance spectroscopy to obtain values for their respective refractive indices and porosities. Absorbance of each sample was also computed using the data from its respective reflectance spectrum. Terahertz emission of each sample was acquired through terahertz - time domain spectroscopy. A decreasing trend in the THz signal power was observed as the porosity of each PSi was increased. This was caused by the decrease in the absorption strength as the silicon crystallite size in the PSi was minimized.
Determination of nutritional parameters of yoghurts by FT Raman spectroscopy
NASA Astrophysics Data System (ADS)
Czaja, Tomasz; Baranowska, Maria; Mazurek, Sylwester; Szostak, Roman
2018-05-01
FT-Raman quantitative analysis of nutritional parameters of yoghurts was performed with the help of partial least squares models. The relative standard errors of prediction for fat, lactose and protein determination in the quantified commercial samples equalled to 3.9, 3.2 and 3.6%, respectively. Models based on attenuated total reflectance spectra of the liquid yoghurt samples and of dried yoghurt films collected with the single reflection diamond accessory showed relative standard errors of prediction values of 1.6-5.0% and 2.7-5.2%, respectively, for the analysed components. Despite a relatively low signal-to-noise ratio in the obtained spectra, Raman spectroscopy, combined with chemometrics, constitutes a fast and powerful tool for macronutrients quantification in yoghurts. Errors received for attenuated total reflectance method were found to be relatively higher than those for Raman spectroscopy due to inhomogeneity of the analysed samples.
Diffuse reflectance spectroscopy for monitoring diabetic foot ulcer - A pilot study
NASA Astrophysics Data System (ADS)
Anand, Suresh; Sujatha, N.; Narayanamurthy, V. B.; Seshadri, V.; Poddar, Richa
2014-02-01
Foot ulceration due to diabetes mellitus is a major problem affecting 12-25% of diabetic subjects in their lifetime. An untreated ulcer further gets infected which causes necrosis leading to amputation of lower extremities. Early identification of risk factors and treatment for these chronic wounds would reduce health care costs and improve the quality of life for people with diabetes. Recent clinical investigations have shown that a series of factors including reduced oxygen delivery and disturbed metabolism have been observed on patients with foot ulceration due to diabetes. Also, these factors can impair the wound healing process. Optical techniques based on diffuse reflectance spectroscopy provide characteristic spectral finger prints shed light on tissue oxygenation levels and morphological composition of a tissue. This study deals with the application of diffuse reflectance intensity ratios based on oxyhemoglobin bands (R542/R580), ratios of oxy- and deoxy-hemoglobin bands (R580/R555), total hemoglobin concentration and hemoglobin oxygen saturation between normal and diabetic foot ulcer sites. Preliminary results obtained are found to be promising indicating the application of reflectance spectroscopy in the assessment of foot ulcer healing.
Zhang, Yong; Cao, Chun-yu; Feng, Wen-ying; Xu, Ming; Su, Zhen-hua; Liu, Xiao-meng; Lü, Wei-jun
2011-03-01
As one of the most powerful tools to investigate the compositions of raw materials and the property of pulp and paper, infrared spectroscopy has played an important role in pulp and paper industry. However, the traditional transmission infrared spectroscopy has not met the requirements of the producing processes because of its disadvantages of time consuming and sample destruction. New technique would be needed to be found. Fourier transform attenuated total reflection infrared spectroscopy (ATR-FTIR) is an advanced spectroscopic tool for nondestructive evaluation and could rapidly, accurately estimate the production properties of each process in pulp and paper industry. The present review describes the application of ATR-FTIR in analysis of pulp and paper industry. The analysis processes will include: pulping, papermaking, environmental protecting, special processing and paper identifying.
ATR-FTIR Spectroscopy in the Undergraduate Chemistry Laboratory: Part I--Fundamentals and Examples
ERIC Educational Resources Information Center
Schuttlefield, Jennifer D.; Grassian, Vicki H.
2008-01-01
Attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectroscopy is a useful technique for measuring the infrared spectra of solids and liquids as well as probing adsorption on particle surfaces. Several examples of the use of FTIR-ATR spectroscopy in different undergraduate chemistry laboratory courses are presented here. These…
NASA Astrophysics Data System (ADS)
Feneberg, Martin; Däubler, Jürgen; Thonke, Klaus; Sauer, Rolf; Schley, Pascal; Goldhahn, Rüdiger
2008-06-01
Unintentionally degenerately doped n -type hexagonal wurtzite InN samples were studied by using Fourier-transform photoluminescence spectroscopy and reflectivity measurements. We found in luminescence overlapping band acceptor (e,A0) transitions related to two different acceptors with a strong enhancement of their intensities close to the Fermi energy of the electrons recombining with the localized holes. Our explanation is in terms of a Fermi-edge singularity of the electrons due to strongly increased electron-hole scattering. Electron-hole pairs with such resonantly enhanced oscillator strengths have been referred to as Mahan excitons. Temperature-dependent reflectivity measurements confirm this interpretation.
Application of Diffuse Reflectance FT-IR Spectroscopy for the Surface Study of Kevlar Fibers
NASA Astrophysics Data System (ADS)
Chatzi, E. G.; Ishida, H.; Koenig, J. L.
1985-12-01
The surfaces of Kevlar-49 aramid fibers, being used in high-performance composite materials, have been characterized by diffuse reflectance Fourier transform infrared (FT-IR) spectroscopy. Enhancement of the surface selectivity of the technique has been achieved using KBr overlayers. The water absorbed by both the skin and the core of the fibers has been characterized by using this technique and the accessibility of the fiber functional groups has been evaluated.
Diagnosis of Breast Cancer Using Fluorescence and Reflectance Spectroscopy
2004-09-01
S. C. Harvey, R. L. Christian , A. Richardson and W. D. Ko, "Large-needle core biopsy: nonmalignant breast abnormalities evaluated with surgical...34 Medical Laser Application 18, 233-248 (2003). 5. Y. Yuanlong, E. J. Celmer, M. Zurawska Szczepaniak and R. R. Alfano , "Excitation spectrum of...Koutcher and R. R. Alfano , "UV reflectance spectroscopy probes DNA and protein changes in human breast tissues," J Clin Laser Med Surg 19, 35-39 (2001
Multispectral detection of cutaneous lesions using spectroscopy and microscopy approaches
NASA Astrophysics Data System (ADS)
Borisova, E.; Genova-Hristova, Ts.; Troyanova, P.; Pavlova, E.; Terziev, I.; Semyachkina-Glushkovskaya, O.; Lomova, M.; Genina, E.; Stanciu, G.; Tranca, D.; Avramov, L.
2018-02-01
Autofluorescence, diffuse-reflectance and transmission spectral, and microscopic measurements were made on different cutaneous neoplastic lesions, namely basal cell carcinoma, squamous cell carcinoma, malignant melanoma, and dysplastic and benign lesions related. Spectroscopic measurements were made on ex vivo tissue samples, and confocal microscopy investigations were made on thin tissue slices. Fluorescence spectra obtained reveal statistically significant differences between the different benign, dysplastic and malignant lesions by the level of emission intensity, as well by spectral shape, which are fingerprints applicable for differentiation algorithms. In reflectance mode the most significant differences are related to the influence of skin pigments - melanin and hemoglobin. Transmission spectroscopy mode gave complementary optical properties information about the tissue samples investigated to that one of reflectance and absorption spectroscopy. Using autofluorescence detection of skin lesions we obtain very good diagnostic performance for distinguishing of nonmelanoma lesions. Using diffuse reflectance and transmission spectroscopy we obtain significant tool for pigmented pathologies differentiation, but it is a tool with moderate sensitivity for non-melanoma lesions detection. One could rapidly increase the diagnostic accuracy of the received combined "optical biopsy" method when several spectral detection techniques are applied in common algorithm for lesions' differentiation. Specific spectral features observed in each type of lesion investigated on micro and macro level would be presented and discussed. Correlation between the spectral data received and the microscopic features observed would be discussed in the report.
NASA Astrophysics Data System (ADS)
Arantes Camargo, Livia; Marques, José, Jr.
2015-04-01
The prediction of erodibility using indirect methods such as diffuse reflectance spectroscopy could facilitate the characterization of the spatial variability in large areas and optimize implementation of conservation practices. The aim of this study was to evaluate the prediction of interrill erodibility (Ki) and rill erodibility (Kr) by means of iron oxides content and soil color using multiple linear regression and diffuse reflectance spectroscopy (DRS) using regression analysis by least squares partial (PLSR). The soils were collected from three geomorphic surfaces and analyzed for chemical, physical and mineralogical properties, plus scanned in the spectral range from the visible and infrared. Maps of spatial distribution of Ki and Kr were built with the values calculated by the calibrated models that obtained the best accuracy using geostatistics. Interrill-rill erodibility presented negative correlation with iron extracted by dithionite-citrate-bicarbonate, hematite, and chroma, confirming the influence of iron oxides in soil structural stability. Hematite and hue were the attributes that most contributed in calibration models by multiple linear regression for the prediction of Ki (R2 = 0.55) and Kr (R2 = 0.53). The diffuse reflectance spectroscopy via PLSR allowed to predict Interrill-rill erodibility with high accuracy (R2adj = 0.76, 0.81 respectively and RPD> 2.0) in the range of the visible spectrum (380-800 nm) and the characterization of the spatial variability of these attributes by geostatistics.
A portable X-ray diffraction apparatus for in situ analyses of masters' paintings
NASA Astrophysics Data System (ADS)
Eveno, Myriam; Duran, Adrian; Castaing, Jacques
2010-09-01
It is rare that the analyses of materials in paintings can be carried out by taking micro-samples. Valuable works of art are best studied in situ by non-invasive techniques. For that purpose, a portable X-ray diffraction and fluorescence apparatus has been designed and constructed at the C2RMF. This apparatus has been used for paintings of Rembrandt, Leonardo da Vinci, Van Gogh, Mantegna, etc. Results are given to illustrate the performance of X-ray diffraction, especially when X-ray fluorescence does not bring sufficient information to conclude.
Study of normal, fibrous and calcified aortic valve tissue by Raman and reflectance spectroscopy
NASA Astrophysics Data System (ADS)
Rodrigues, Kátia Calligaris; Munin, Egberto; Alves, Leandro P.; Silveira, Fabrício L.; Junior, Landulfo S.; De Lima, Carlos J.; Lázzaro, João C.; De Souza, Genivaldo C.; Piotto, José A. B.; Pacheco, Marcos T. T.; Zângaro, Renato A.
2007-02-01
Several studies have identified the degree of aortic valve calcification as a strong predictor both for the progression and outcome of aortic stenosis. In industrialized countries, aortic valve stenosis is most frequently caused by progressive calcification and degeneration of aortic cusps. However, there are no accurate methods to quantify the extent of aortic valve calcification. To provide a non-invasive alternative to biopsy, a range of optical methods have been investigated, including Raman and reflectance spectroscopy. A Raman spectrum can be used to access the molecular constitution of a particular tissue and classify it. Raman spectroscopy is largely used in the quantification and evaluation of human atherosclerosis, being a powerful technique for performing biochemical analysis without tissue removal. Nevertheless, increased thickness and disorganization of the collagen fibre network and extracellular matrix are known to affect the diffuse spectral reflectance of the tissue. A catheter with the "6 around 1" configuration, the central fiber transmit laser radiation to the sample and the scattered light is collected by the other six surrounding fibers, was used both for Raman and reflectance spectroscopy. A white light (krypton lamp, flashtube Model FX 1160 Perkin Elmer, USA) excitation was used for reflectance measurements. A Ti-sapphire (785nm, Spectra Physics, model 3900S, USA) laser, pumped by an argon laser (Spectra Physics, model Stabilite 2017, USA) was used as the near infrared Raman set up. Several ex-vivo spectra of aortic valve samples were analyzed. The results show a promising way to differentiate normal, fibrous and calcified tissue in aortic valve.
NASA Astrophysics Data System (ADS)
Nawar, Said; Buddenbaum, Henning; Hill, Joachim
2014-05-01
A rapid and inexpensive soil analytical technique is needed for soil quality assessment and accurate mapping. This study investigated a method for improved estimation of soil clay (SC) and organic matter (OM) using reflectance spectroscopy. Seventy soil samples were collected from Sinai peninsula in Egypt to estimate the soil clay and organic matter relative to the soil spectra. Soil samples were scanned with an Analytical Spectral Devices (ASD) spectrometer (350-2500 nm). Three spectral formats were used in the calibration models derived from the spectra and the soil properties: (1) original reflectance spectra (OR), (2) first-derivative spectra smoothened using the Savitzky-Golay technique (FD-SG) and (3) continuum-removed reflectance (CR). Partial least-squares regression (PLSR) models using the CR of the 400-2500 nm spectral region resulted in R2 = 0.76 and 0.57, and RPD = 2.1 and 1.5 for estimating SC and OM, respectively, indicating better performance than that obtained using OR and SG. The multivariate adaptive regression splines (MARS) calibration model with the CR spectra resulted in an improved performance (R2 = 0.89 and 0.83, RPD = 3.1 and 2.4) for estimating SC and OM, respectively. The results show that the MARS models have a great potential for estimating SC and OM compared with PLSR models. The results obtained in this study have potential value in the field of soil spectroscopy because they can be applied directly to the mapping of soil properties using remote sensing imagery in arid environment conditions. Key Words: soil clay, organic matter, PLSR, MARS, reflectance spectroscopy.
Applications of Quantum Cascade Laser Spectroscopy in the Analysis of Pharmaceutical Formulations.
Galán-Freyle, Nataly J; Pacheco-Londoño, Leonardo C; Román-Ospino, Andrés D; Hernandez-Rivera, Samuel P
2016-09-01
Quantum cascade laser spectroscopy was used to quantify active pharmaceutical ingredient content in a model formulation. The analyses were conducted in non-contact mode by mid-infrared diffuse reflectance. Measurements were carried out at a distance of 15 cm, covering the spectral range 1000-1600 cm(-1) Calibrations were generated by applying multivariate analysis using partial least squares models. Among the figures of merit of the proposed methodology are the high analytical sensitivity equivalent to 0.05% active pharmaceutical ingredient in the formulation, high repeatability (2.7%), high reproducibility (5.4%), and low limit of detection (1%). The relatively high power of the quantum-cascade-laser-based spectroscopic system resulted in the design of detection and quantification methodologies for pharmaceutical applications with high accuracy and precision that are comparable to those of methodologies based on near-infrared spectroscopy, attenuated total reflection mid-infrared Fourier transform infrared spectroscopy, and Raman spectroscopy. © The Author(s) 2016.
NASA Astrophysics Data System (ADS)
Kaniyappan, Udayakumar; Gnanatheepam, Einstein; Aruna, Prakasarao; Dornadula, Koteeswaran; Ganesan, Singaravelu
2017-02-01
Cancer is one of the most common threat to human beings and it increases at an alarming level around the globe. In recent years, due to the advancements in opto-electronic technology, various optical spectroscopy techniques have emerged to assess the photophysicochemical and morphological conditions of normal and malignant tissues in micro as well as in macroscopic scale. In this regard, diffuse reflectance spectroscopy is considered to be the simplest, cost effective and rapid technique in diagnosis of cancerous tissues. In the present study, the hemoglobin concentration in normal and cancerous oral tissues was quantified and subsequent statistical analysis has been carried out to verify the diagnostic potentiality of the technique.
Transmission versus reflectance spectroscopy for quantitation
NASA Astrophysics Data System (ADS)
Gardner, Craig M.
2018-01-01
The objective of this work was to compare the accuracy of analyte concentration estimation when using transmission versus diffuse reflectance spectroscopy of a scattering medium. Monte Carlo ray tracing of light through the medium was used in conjunction with pure component absorption spectra and Beer-Lambert absorption along each ray's pathlength to generate matched sets of pseudoabsorbance spectra, containing water and six analytes present in skin. PLS regression models revealed an improvement in accuracy when using transmission compared to reflectance for a range of medium thicknesses and instrument noise levels. An analytical expression revealed the source of the accuracy degradation with reflectance was due both to the reduced collection efficiency for a fixed instrument etendue and to the broad pathlength distribution that detected light travels in the medium before exiting from the incident side.
Reflectance and fluorescence spectroscopies in photodynamic therapy
NASA Astrophysics Data System (ADS)
Finlay, Jarod C.
In vivo fluorescence spectroscopy during photodynamic therapy (PDT) has the potential to provide information on the distribution and degradation of sensitizers, the formation of fluorescent photoproducts and changes in tissue autofluorescence induced by photodynamic treatment. Reflectance spectroscopy allows quantification of light absorption and scattering in tissue. We present the results of several related studies of fluorescence and reflectance spectroscopy and their applications to photodynamic dosimetry. First, we develop and test an empirical method for the correction of the distortions imposed on fluorescence spectra by absorption and scattering in turbid media. We characterize the irradiance dependence of the in vivo photobleaching of three sensitizers, protoporphyrin IX (PpIX), Photofrin and mTHPC, in a rat skin model. The photobleaching and photoproduct formation of PpIX exhibit irradiance dependence consistent with singlet oxygen (1O2)-mediated bleaching. The bleaching of mTHPC occurs in two phases, only one of which is consistent with a 1O 2-mediated mechanism. Photofrin's bleaching is independent of irradiance, although its photoproduct formation is not. This can be explained by a mixed-mechanism bleaching model. Second, we develop an algorithm for the determination of tissue optical properties using diffuse reflectance spectra measured at a single source-detector separation and demonstrate the recovery of the hemoglobin oxygen dissociation curve from tissue-simulating phantoms containing human erythrocytes. This method is then used to investigate the heterogeneity of oxygenation response in murine tumors induced by carbogen inhalation. We find that while the response varies among animals and within each tumor, the majority of tumors exhibit an increase in blood oxygenation during carbogen breathing. We present a forward-adjoint model of fluorescence propagation that uses the optical property information acquired from reflectance spectroscopy to obtain the undistorted fluorescence spectrum over a wide range of optical properties. Finally, we investigate the ability of the forward-adjoint theory to extract undistorted fluorescence and optical property information simultaneously from a single measured fluorescence spectrum. This method can recover the hemoglobin oxygen dissociation curve in tissue-simulating phantoms with an accuracy comparable to that of reflectance-based methods while correcting distortions in the fluorescence over a wide range of absorption and scattering coefficients.
AVIRIS data calibration information: Wasatch Mountains and Park City region, Utah
Rockwell, Barnaby W.; Clark, Roger N.; Livo, K. Eric; McDougal, Robert R.; Kokaly, Raymond F.
2002-01-01
This report contains information regarding the reflectance calibration of spectroscopic imagery acquired over the Wasatch Mountains and Park City region, Utah, by the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) sensor on August 5, 1998. This information was used by the USGS Spectroscopy Laboratory to calibrate the Park City AVIRIS imagery to unitless reflectance prior to spectral analysis. The Utah AVIRIS data were analyzed as a part of the USEPA-USGS Utah Abandoned Mine Lands Imaging Spectroscopy Project.
NASA Technical Reports Server (NTRS)
Mookherji, T.
1976-01-01
Outgassing, deposition, and desorption kinetics of silicone compounds, are examined as examples of optical surface contaminants of spacecraft windows. Their behavior in a space environment after exposure to ultraviolet radiation is also examined. The use of internal reflection spectroscopy is shown to provide a viable means of real-time, in-situ identification of contaminants of orbiting spacecraft. The instrumental techniques are proposed as the basis of further investigations and the development of flight hardware.
NASA Astrophysics Data System (ADS)
Darvin, Maxim E.; Magnussen, Björn; Lademann, Juergen; Köcher, Wolfgang
2016-09-01
Non-invasive measurement of carotenoid antioxidants in human skin is one of the important tasks to investigate the skin physiology in vivo. Resonance Raman spectroscopy and reflection spectroscopy are the most frequently used non-invasive techniques in dermatology and skin physiology. In the present study, an improved method based on multiple spatially resolved reflection spectroscopy (MSRRS) was introduced. The results obtained were compared with those obtained using the ‘gold standard’ resonance Raman spectroscopy method and showed strong correlations for the total carotenoid concentration (R = 0.83) as well as for lycopene (R = 0.80). The measurement stability was confirmed to be better than 10% within the total temperature range from 5 °C to + 30 °C and pressure contact between the skin and the MSRRS sensor from 800 Pa to 18 000 Pa. In addition, blood samples taken from the subjects were analyzed for carotenoid concentrations. The MSRRS sensor was calibrated on the blood carotenoid concentrations resulting in being able to predict with a correlation of R = 0.79. On the basis of blood carotenoids it could be demonstrated that the MSRRS cutaneous measurements are not influenced by Fitzpatrick skin types I-VI. The MSRRS sensor is commercially available under the brand name biozoom.
Sediment mineralogy based on visible and near-infrared reflectance spectroscopy
Jarrard, R.D.; Vanden Berg, M.D.; ,
2006-01-01
Visible and near-infrared spectroscopy (VNIS) can be used to measure reflectance spectra (wavelength 350-2500 nm) for sediment cores and samples. A local ground-truth calibration of spectral features to mineral percentages is calculated by measuring reflectance spectra for a suite of samples of known mineralogy. This approach has been tested on powders, core plugs and split cores, and we conclude that it works well on all three, unless pore water is present. Initial VNIS studies have concentrated on determination of relative proportions of carbonate, opal, smectite and illite in equatorial Pacific sediments. Shipboard VNIS-based determination of these four components was demonstrated on Ocean Drilling Program Leg 199. ?? The Geological Society of London 2006.
NASA Technical Reports Server (NTRS)
Hayes, J. D.
1972-01-01
The feasibility of monitoring volatile contaminants in a large space simulation chamber using techniques of internal reflection spectroscopy was demonstrated analytically and experimentally. The infrared spectral region was selected as the operational spectral range in order to provide unique identification of the contaminants along with sufficient sensitivity to detect trace contaminant concentrations. It was determined theoretically that a monolayer of the contaminants could be detected and identified using optimized experimental procedures. This ability was verified experimentally. Procedures were developed to correct the attenuated total reflectance spectra for thick sample distortion. However, by using two different element designs the need for such correction can be avoided.
Photosensitizer quantitation in vivo by flourescence microsampling
NASA Astrophysics Data System (ADS)
Pogue, Brian W.; Burke, Gregory C.; Lee, Claudia C.; Hoopes, P. Jack
2000-06-01
Photodynamic therapy can provide a reliable method of tumor destruction when the appropriate dosimetry is applied. Current dosimetry practice involves quantification of the drug and light doses applied to the tumor, but it would be desirable to monitor in vivo light and drug levels to provide the most accurate determination of dosimetry. In vivo measurements can be used to minimize variations in treatment response due to inter-animal variability, by providing animal-specific or patient-specific treatment planning. This study reports on the development of a micro-sampling method to measure fluorescence from tissue, which is not significantly affected by the tissue optical properties. The system measures fluorescence from the surface of a tissue, using a fiber bundle composed of individual 100 micron fibers which ar all spaced apart by 700 microns from one another at the tissue contact end. This design provides sampling of the fluorescence at multiple sites to increase the signal intensity, while maintaining a micro- sampling of the tissue volume just below the surface. The calibration studies here indicate that the 1/e sampling depth is near 60 microns when measured in optical phantoms, which are similar to typical tissue properties. The probe fluorescence signal is independent of blood concentration up to a maximum of 10% blood by volume, which is similar to most tumor tissue. Animal tests indicate that the sensitivity to drug concentration is essentially the same in when measured in murine liver and muscle tissues, both in vivo and ex vivo. These preliminary calibration results suggest that the probe can be used to measure photosensitizer uptake in vivo non- invasively and rapidly via conversion of fluorescence intensity to photosensitizer concentration.
Tubaon, Ria Marni; Haddad, Paul R; Quirino, Joselito P
2017-03-10
The presence of inorganic anions in a sample interferes with mass spectrometric (MS) analysis. Here, a simple method to remove these ions from a liquid sample in one-step is described. The inorganic anions present in a 50μL sample were extracted into a low pH solution inside a 200μm i.d.×33cm long capillary by the use of an electric field. The selective removal of unwanted anions and retention of target analytes was accomplished by control of the apparent electrophoretic velocities of anions and analytes at a boundary that separated the sample and extraction solution. No physical barrier (e.g., membrane) was required and with the boundary situated at the tip of the capillary, efficient removal of inorganic anions (e.g., >80% removal) and good recovery of target analytes (e.g., >80% recovery) were achieved. The time required for removal of the inorganic anions was found to depend on their initial concentrations. The removal process was investigated using different concentrations of bromide and nitrate (as potassium salts) and negatively chargeable drugs as target analytes. This micro-sample clean-up technique used no organic solvents and little consumables and was studied to the determination of 0.6μg/L arsenic and 8.3μg/L vanadium in 500mg/L sodium chloride using inductively coupled plasma MS and 50μM angiotensin I in 1000mg/L sodium chloride using electrospray ionisation MS. Micro-sample clean-up was performed for 45min at 3kV in both demonstrations. The calculated recoveries for the metals at trace levels were 110-130%, and for the peptide was 103.8%. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Hoogland, F. G.; Boon, J. J.
2009-07-01
Poly(ethylene glycol) (PEG) compounds in artists' acrylic emulsion paint products from different paint manufacturers, ranging from base emulsions (Rohm and Haas, Röhm and Scott Bader), to modified emulsions and complete paints (Rowney, Winsor and Newton, Golden, Liquitex, Lascaux), were characterised with a newly developed mass spectrometric method which combines data from Matrix assisted laser desorption/ionisation mass spectrometry (MALDI-MS) and nano-electrospray ionisation mass spectrometry (nano-ESI-MS(MS)). MALDI-MS was used for the determination of the molar mass distribution (MMD) and calculation of the molar mass averages (Mw and Mn), the polydispersity index (D) and the relative amount of a specific distribution if multiple PEGs were present. Electrospray ionisation mass spectrometry was used for the end-group analysis. Three different classes of polymers was found being PEG, polypropylene glycol (PPG) and a block copolymer of polyethylene glycol/polypropylene glycol (PEG/PPG) with molar mass averages ranging from 400 to 4200 Da. PEG compounds with a nonylphenyl or an octylphenyl hydrophobic end-group are most common. The hydrophilic end-groups observed are hydroxide and/or sulphate. Water extracts of microsamples from a palette by David Hockney dating from 1970 and samples paintings by Patrick Caulfield (1936-2005) and John Hoyland (born in 1934) were investigated with the same technique. Although some artist paint manufacturers use the same specific base emulsions to make their paints, the composition of the PEG compounds present in the water extracts of the palette and paintings samples made it possible, in some cases, to suggest a specific brand of paint used by the artist.
An improved technique for studying pleural fluid pressure and composition in rabbits.
Del Fabbro, M
1998-07-01
Knowledge of pleural liquid pressure (Pliq) and composition is crucial for studies concerning intrapleural fluid dynamics, and pleural fluid turnover. We measured Pliq at intercostal and costal levels in anaesthetized spontaneously breathing rabbits using a minimally invasive method that assures a long-lasting hydraulic continuity between the pleural liquid and the recording system. Polyethylene tubes were glued either to the exposed endothoracic fascia or inserted into a rib to provide a scaled connection to the recording system. After inducing a pneumothorax with nitrous oxide (N2O) via an intrapleural cannula, a hole (approximately 0.7 mm2) was pierced in the parietal pleura through the tube lumen. The tubes were then connected to pressure transducers and the whole system was filled with heparinized saline to the level of the parietal pleura; finally the pneumo-thorax was removed after N2O washout and Pliq recordings were performed. A different kind of tube was used to obtain microsamples of pleural fluid (2.5-3 microliters) during spontaneous breathing; colloid osmotic pressure of the microsamples (pi liq) was measured with an osmometer, and averaged 9.3 +/- 1.5 cm H2o (n = 70 samples). When pooled and plotted against lung height end-expiratory intercostal and costal Pliq data scattered along a single regression line with a slope of -0.83 and -0.90 cm H2O cm(-1) in supine and prone animals, respectively. End-inspiratory costal Pliq was significantly more subatmospheric than intercostal in the ventral region of the chest (P < 0.05), and less subatmospheric in the dorsal region, regardless of posture. The techniques presented here could be helpful in gaining a greater insight into the physiology and pathophysiology of the pleural space in terms of pleural fluid dynamics and turnover.
Fabila, Diego; de la Rosa, José Manuel; Stolik, Suren; Moreno, Edgard; Suárez-Álvarez, Karina; López-Navarrete, Giuliana; Guzmán, Carolina; Aguirre-García, Jesús; Acevedo-García, Christian; Kershenobich, David; Escobedo, Galileo
2012-12-01
A novel application of diffuse reflectance and fluorescence spectroscopy in the assessment of liver fibrosis is here reported. To induce different stages of liver fibrosis, a sufficient number of male Wistar rats were differentially exposed to chronic administration with carbon tetrachloride. Then, diffuse reflectance and fluorescence spectra were in vivo measured from the liver surface of each animal by a minimal invasive laparoscopic procedure. The liver fibrosis degree was conventionally determined by means of histological examination using the Mason's Trichrome stain, accompanied by hepatic expression of α-sma, and evaluation of the ALT/AST serum levels. The liver from rats exhibiting higher grades of fibrosis showed a significant increase in diffuse reflectance and fluorescence intensity when compared with control animals. At 365 nm, the diffuse reflectance spectrum exhibited an increase of 4 and 3-fold in mild and advanced fibrotic rats, respectively, when compared to the control group. Similarly, the fluorescence emission at 493 nm was 2-fold higher in fibrotic animals than in controls. By using fluorescence intensity, discrimination algorithms indicated 73% sensitivity and 94% specificity for recognition of hepatic fibrosis, while for diffuse reflectance, these values increased up to 85% and 100%, respectively. Taking into consideration there is a special need for developing new diagnostic approaches focused on detecting different stages of liver fibrosis with minimal invasiveness, these results suggest that diffuse reflectance and fluorescence spectroscopy could be worthy of further exploration in patients with liver disease. Copyright © 2012 Elsevier B.V. All rights reserved.
Karabudak, Engin; Kas, Recep; Ogieglo, Wojciech; Rafieian, Damon; Schlautmann, Stefan; Lammertink, R G H; Gardeniers, Han J G E; Mul, Guido
2013-01-02
Attenuated total reflection-infrared (ATR-IR) spectroscopy is increasingly used to characterize solids and liquids as well as (catalytic) chemical conversion. Here we demonstrate that a piece of silicon wafer cut by a dicing machine or cleaved manually can be used as disposable internal reflection element (IRE) without the need for polishing and laborious edge preparation. Technical aspects, fundamental differences, and pros and cons of these novel disposable IREs and commercial IREs are discussed. The use of a crystal (the Si wafer) in a disposable manner enables simultaneous preparation and analysis of substrates and application of ATR spectroscopy in high temperature processes that may lead to irreversible interaction between the crystal and the substrate. As representative application examples, the disposable IREs were used to study high temperature thermal decomposition and chemical changes of polyvinyl alcohol (PVA) in a titania (TiO(2)) matrix and assemblies of 65-450 nm thick polystyrene (PS) films.
Apyari, V V; Dmitrienko, S G; Ostrovskaya, V M; Anaev, E K; Zolotov, Y A
2008-07-01
Polyurethane foam (PUF) has been suggested as a solid polymeric reagent for determination of nitrite. The determination is based on the diazotization of end toluidine groups of PUF with nitrite in acidic medium followed by coupling of polymeric diazonium cation with 3-hydroxy-7,8-benzo-1,2,3,4-tetrahydroquinoline. The intensely colored polymeric azodye formed in this reaction can be used as a convenient analytic form for the determination of nitrite by diffuse reflectance spectroscopy (c (min) = 0.7 ng mL(-1)). The possibility of using a desktop scanner, digital camera, and computer data processing for the numerical evaluation of the color intensity of the polymeric azodye has been investigated. A scanner and digital camera can be used for determination of nitrite with the same sensitivity and reproducibility as with diffuse reflectance spectroscopy. The approach developed was applied for determination of nitrite in river water and human exhaled breath condensate.
NASA Astrophysics Data System (ADS)
Fabila, D. A.; Hernández, L. F.; de la Rosa, J.; Stolik, S.; Arroyo-Camarena, U. D.; López-Vancell, M. D.; Escobedo, G.
2013-11-01
Liver fibrosis is the decisive step towards the development of cirrhosis; its early detection affects crucially the diagnosis of liver disease, its prognosis and therapeutic decision making. Nowadays, several techniques are employed to this task. However, they have the limitation in estimating different stages of the pathology. In this paper we present a preliminary study to evaluate if optical spectroscopy can be employed as an auxiliary tool of diagnosis of biopsies of human liver tissue to differentiate the fibrosis stages. Ex vivo fluorescence and diffuse reflectance spectra were acquired from biopsies using a portable fiber-optic system. Empirical discrimination algorithms based on fluorescence intensity ratio at 500 nm and 680 nm as well as diffuse reflectance intensity at 650 nm were developed. Sensitivity and specificity of around 80% and 85% were respectively achieved. The obtained results show that combined use of fluorescence and diffuse reflectance spectroscopy could represent a novel and useful tool in the early evaluation of liver fibrosis.
Heise, H M; Lampen, P; Stücker, M
2003-11-01
The supply of oxygen to the viable skin tissue within the upper layers is not only secured by the cutaneous blood vascular system, but to a significant part also by oxygen diffusion from the atmosphere through the horny layer. The aim of this study was to examine whether changes in haemoglobin oxygenation can be observed within the isolated perfused bovine udder skin used as a skin model by removing the upper horny layer by adhesive tape stripping. Diffuse reflectance spectroscopy in the visible spectral range was used for non-invasive characterisation of haemoglobin oxygenation in skin under in vitro conditions. Mid-infrared attenuated total reflectance spectroscopy was employed for analysing the surface layer of the stratum corneum with respect to keratin, water and lipid components. Skin barrier disruption was achieved by repeated stripping of superficial corneocyte layers by adhesive tape. Significant changes in skin haemoglobin oxygenation were observed for skin areas with reduced lipid concentration and a reduced stratum corneum layer, as determined from the quantitative evaluation of the diffuse reflectance skin spectra. The result can be interpreted as an increase of oxygen diffusion after the removal of the upper horny layer.
NASA Astrophysics Data System (ADS)
Sujatha, N.; Anand, B. S. Suresh; Nivetha, K. Bala; Narayanamurthy, V. B.; Seshadri, V.; Poddar, R.
2015-07-01
Light-based diagnostic techniques provide a minimally invasive way for selective biomarker estimation when tissues transform from a normal to a malignant state. Spectroscopic techniques based on diffuse reflectance characterize the changes in tissue hemoglobin/oxygenation levels during the tissue transformation process. Recent clinical investigations have shown that changes in tissue oxygenation and microcirculation are observed in diabetic subjects in the initial and progressive stages. In this pilot study, we discuss the potential of diffuse reflectance spectroscopy (DRS) in the visible (Vis) range to differentiate the skin microcirculatory hemoglobin levels between normal and advanced diabetic subjects with and without neuropathy. Average concentration of hemoglobin as well as hemoglobin oxygen saturation within the probed tissue volume is estimated for a total of four different sites in the foot sole. The results indicate a statistically significant decrease in average total hemoglobin and increase in hemoglobin oxygen saturation levels for diabetic foot compared with a normal foot. The present study demonstrates the ability of reflectance spectroscopy in the Vis range to determine and differentiate the changes in tissue hemoglobin and hemoglobin oxygen saturation levels in normal and diabetic subjects.
Reflectance spectroscopy: quantitative analysis techniques for remote sensing applications.
Clark, R.N.; Roush, T.L.
1984-01-01
Several methods for the analysis of remotely sensed reflectance data are compared, including empirical methods and scattering theories, both of which are important for solving remote sensing problems. The concept of the photon mean path length and the implications for use in modeling reflectance spectra are presented.-from Authors
Soft tissue differentiation by diffuse reflectance spectroscopy
NASA Astrophysics Data System (ADS)
Zam, Azhar; Stelzle, Florian; Nkenke, Emeka; Tangermann-Gerk, Katja; Schmidt, Michael; Adler, Werner; Douplik, Alexandre
2009-07-01
Laser surgery gives the possibility to work remotely which leads to high precision, little trauma and high level sterility. However these advantages are coming with the lack of haptic feedback during the laser ablation of tissue. Therefore additional means are required to control tissue-specific ablation during laser surgery supporting the surgeon regardless of experience and skills. Diffuse Reflectance Spectroscopy provides a straightforward and simple approach for optical tissue differentiation. We measured diffuse reflectance from four various tissue types ex vivo. We applied Linear Discriminant Analysis (LDA) to differentiate the four tissue types and computed the area under the ROC curve (AUC). Special emphasis was taken on the identification of nerve as the most crucial tissue for maxillofacial surgery. The results show a promise for differentiating soft tissues as guidance for tissue-specific laser surgery by means of the diffuse reflectance.
Transmission versus reflectance spectroscopy for quantitation.
Gardner, Craig M
2018-01-01
The objective of this work was to compare the accuracy of analyte concentration estimation when using transmission versus diffuse reflectance spectroscopy of a scattering medium. Monte Carlo ray tracing of light through the medium was used in conjunction with pure component absorption spectra and Beer-Lambert absorption along each ray's pathlength to generate matched sets of pseudoabsorbance spectra, containing water and six analytes present in skin. PLS regression models revealed an improvement in accuracy when using transmission compared to reflectance for a range of medium thicknesses and instrument noise levels. An analytical expression revealed the source of the accuracy degradation with reflectance was due both to the reduced collection efficiency for a fixed instrument etendue and to the broad pathlength distribution that detected light travels in the medium before exiting from the incident side. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).
Hollow waveguide cavity ringdown spectroscopy
NASA Technical Reports Server (NTRS)
Dreyer, Chris (Inventor); Mungas, Greg S. (Inventor)
2012-01-01
Laser light is confined in a hollow waveguide between two highly reflective mirrors. This waveguide cavity is used to conduct Cavity Ringdown Absorption Spectroscopy of loss mechanisms in the cavity including absorption or scattering by gases, liquid, solids, and/or optical elements.
Aernouts, B; Polshin, E; Lammertyn, J; Saeys, W
2011-11-01
The composition of produced milk has great value for the dairy farmer. It determines the economic value of the milk and provides valuable information about the metabolism of the corresponding cow. Therefore, online measurement of milk components during milking 2 or more times per day would provide knowledge about the current health and nutritional status of each cow individually. This information provides a solid basis for optimizing cow management. The potential of visible and near-infrared (Vis/NIR) spectroscopy for predicting the fat, crude protein, lactose, and urea content of raw milk online during milking was, therefore, investigated in this study. Two measurement modes (reflectance and transmittance) and different wavelength ranges for Vis/NIR spectroscopy were evaluated and their ability to measure the milk composition online was compared. The Vis/NIR reflectance measurements allowed for very accurate monitoring of the fat and crude protein content in raw milk (R(2)>0.95), but resulted in poor lactose predictions (R(2)<0.75). In contrast, Vis/NIR transmittance spectra of the milk samples gave accurate fat and crude protein predictions (R(2)>0.90) and useful lactose predictions (R(2)=0.88). Neither Vis/NIR reflectance nor transmittance spectroscopy lead to an acceptable prediction of the milk urea content. Transmittance spectroscopy can thus be used to predict the 3 major milk components, but with lower accuracy for fat and crude protein than the reflectance mode. Moreover, the small sample thickness (1mm) required for NIR transmittance measurement considerably complicates its online use. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
ERIC Educational Resources Information Center
Schuttlefield, Jennifer D.; Larsen, Sarah C.; Grassian, Vicki H.
2008-01-01
Attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectroscopy is a useful technique for measuring the infrared spectra of solids and liquids as well as probing adsorption on particle surfaces. The use of FTIR-ATR spectroscopy in organic and inorganic chemistry laboratory courses as well as in undergraduate research was presented…
Devpura, Suneetha; Pattamadilok, Bensachee; Syed, Zain U; Vemulapalli, Pranita; Henderson, Marsha; Rehse, Steven J; Hamzavi, Iltefat; Lim, Henry W; Naik, Ratna
2011-06-01
Quantification of skin changes due to acanthosis nigricans (AN), a disorder common among insulin-resistant diabetic and obese individuals, was investigated using two optical techniques: diffuse reflectance spectroscopy (DRS) and colorimetry. Measurements were obtained from AN lesions on the neck and two control sites of eight AN patients. A principal component/discriminant function analysis successfully differentiated between AN lesion and normal skin with 87.7% sensitivity and 94.8% specificity in DRS measurements and 97.2% sensitivity and 96.4% specificity in colorimetry measurements.
The Bone Black Pigment Identification by Noninvasive, In Situ Infrared Reflection Spectroscopy
Malagodi, Marco; Vagnini, Manuela
2018-01-01
Two real case studies, an oil painting on woven paper and a cycle of mural paintings, have been presented to validate the use of infrared reflection spectroscopy as suitable technique for the identification of bone black pigment. By the use of the sharp weak band at 2013 cm−1, it has been possible to distinguish animal carbon-based blacks by a noninvasive method. Finally, an attempt for an eventual assignment for the widely used sharp band at 2013 cm−1 is discussed. PMID:29736290
NASA Astrophysics Data System (ADS)
Goryachuk, A. A.; Khodzitsky, M. K.; Borovkova, M. A.; Khamid, A. K.; Dutkinskii, P. S.; Shishlo, D. A.
2016-08-01
Samples of fresh excised tissues obtained from patients who had undergone gastric cancer have been investigated. Samples were consisted of cancer zone, normal zone and zone mixed of normal and cancer tissues. Their optical properties and spectral features were investigated by terahertz time-domain spectroscopy (TDS) in reflection mode. It was found that waveforms of reflected signals from normal and cancer tissues were well distinguished so it can be concluded that it is easy to discriminate gastric cancer tissue from normal by using THz TDS.
Method of high-precision microsampled blood and plasma mass densitometry
NASA Technical Reports Server (NTRS)
Hinghofer-Szalkay, H.
1986-01-01
The reliability of the mechanical oscillator technique for blood and plasma density measurements on samples of volumes less than 0.1 ml is examined, and a precision of 0.001 g/l is found if plasma-isodensic heparin solution and siliconized densitometers are employed. Sources of measurement errors in the density determinations include storage of plasma samples, inhomogeneity of blood samples, and density reading before adequate temperature equilibration. In tests of plasma sample storage, the best reproducibility was obtained with samples kept at 4 C. Linear correlations were found between plasma density and plasma protein concentration, blood density and blood hemoglobin concentration, and erythrocyte density and MCHC.
Integrated titer plate-injector head for microdrop array preparation, storage and transfer
Swierkowski, Stefan P.
2000-01-01
An integrated titer plate-injector head for preparing and storing two-dimensional (2-D) arrays of microdrops and for ejecting part or all of the microdrops and inserting same precisely into 2-D arrays of deposition sites with micrometer precision. The titer plate-injector head includes integrated precision formed nozzles with appropriate hydrophobic surface features and evaporative constraints. A reusable pressure head with a pressure equalizing feature is added to the titer plate to perform simultaneous precision sample ejection. The titer plate-injector head may be utilized in various applications including capillary electrophoresis, chemical flow injection analysis, microsample array preparation, etc.
Fiber optics reflectance spectroscopy (45°x: 45°) for color analysis of dental composite.
Gargano, Marco; Ludwig, Nicola; Federighi, Veronica; Sykes, Ros; Lodi, Giovanni; Sardella, Andrea; Carrassi, Antonio; Varoni, Elena M
2016-08-01
To evaluate the application of a fiber optic reflectance spectroscopy (FORS) prototype probe for 45°x: 45° FORS for determining color of dental materials. A portable spectrophotometer with a highly manageable fiber optics co-axial probe was used to apply 45°x: 45° FORS for color matching in restorative dentistry. The color coordinates in CIELAB space of two dental shade guides and of the corresponding photopolymerized composites were collected and compared. The 45°x: 45° FORS with the co-axial probe (test system), the integrating sphere spectroscopy (reference system) and a commercial dental colorimeter (comparator system) were used to collect data and calculate color differences (ΔE and ΔE00). FORS system displayed high repeatability, reproducibility and accuracy. ΔE and ΔE00 values between the shade-guide, each other, and the corresponding composites resulted above the clinically acceptable limit. The 45°x: 45° FORS test system demonstrated suitable in vitro performance for dental composite color evaluation. 45°x: 45° fiber optic reflectance spectroscopy allows reliable color analysis of small surfaces of dental composites, favoring the color matching of material with the closely surrounding dental tissue, and confirming significant color differences between shade guide tabs and photo-polymerized composites.
Full scattering profile for detecting physiological tissue properties
NASA Astrophysics Data System (ADS)
Duadi, Hamootal; Fixler, Dror
2017-02-01
Light reflectance and transmission from soft tissue has been utilized in noninvasive clinical measurement devices such as the photoplethysmograph (PPG) and reflectance pulse oximeter. Most methods of near infrared (NIR) spectroscopy focus on the volume reflectance from a semi-infinite sample, while very few measure transmission. We have previously shown that examining the full scattering profile (FSP), which is the angular distribution of exiting photons, provides more comprehensive information when measuring from a cylindrical tissue, such as earlobe, fingertip and pinched tissue. Our hypothesis is that the change in blood vessel diameter is more significant than the change in optical properties. The findings of this work demonstrate a realistic model for optical tissue measurements such as NIR spectroscopy, PPG and pulse oximetery.
Reflectance spectroscopy for noninvasive evaluation of hair follicle stage
NASA Astrophysics Data System (ADS)
Liu, Caihua; Guan, Yue; Wang, Jianru; Zhong, Xiewei; Liu, Xiuli; Zhu, Dan
2015-05-01
Hair follicle offers an excellent model for systems biology and regenerative medicine. So far, the stages of hair follicle growth have been evaluated by histological examination. In this work, a noninvasive spectroscopy was proposed by measuring the diffuse reflectance of mouse skin and analyzing the melanin value. Results show that the skin diffuse reflectance was relatively high when hair follicles were at the telogen stage and at the beginning of the anagen stage, and decreased with the progression of the anagen stage. When the hair follicle entered into the catagen stage, the diffuse reflectance gradually increased. The changes in the melanin content of skin had contrary dynamics. Substages of the hair follicle cycle could be distinguished by comparing the changes in melanin value with the histological examination. This study provided a new method for noninvasive evaluation of the hair follicle stage, and should be valuable for basic and therapeutic investigations on hair regeneration.
NASA Astrophysics Data System (ADS)
Kanick, Stephen Chad; van der Leest, Cor; Aerts, Joachim G. J. V.; Hoogsteden, Henk C.; Kaščáková, Slávka; Sterenborg, Henricus J. C. M.; Amelink, Arjen
2010-01-01
We describe the incorporation of a single-fiber reflectance spectroscopy probe into the endoscopic ultrasound fine-needle aspiration (EUS-FNA) procedure utilized for lung cancer staging. A mathematical model is developed to extract information about the physiological and morphological properties of lymph tissue from single-fiber reflectance spectra, e.g., microvascular saturation, blood volume fraction, bilirubin concentration, average vessel diameter, and Mie slope. Model analysis of data from a clinical pilot study shows that the single-fiber reflectance measurement is capable of detecting differences in the physiology between normal and metastatic lymph nodes. Moreover, the clinical data show that probe manipulation within the lymph node can perturb the in vivo environment, a concern that must be carefully considered when developing a sampling strategy. The data show the feasibility of this novel technique; however, the potential clinical utility has yet to be determined.
Glykou, A; Eriksson, G; Storå, J; Schmitt, M; Kooijman, E; Lidén, K
2018-05-04
Strontium isotope ratios ( 87 Sr/ 86 Sr) in modern-day marine environments are considered to be homogeneous (~0.7092). However, in the Baltic Sea, the Sr ratios are controlled by mixing seawater and continental drainage from major rivers discharging into the Baltic. This pilot study explores if variations in Sr can be detected in marine mammals from archaeological sites in the Baltic Sea. 87 Sr/ 86 Sr ratios were measured in tooth enamel from three seal species by laser ablation (LA)-MC-ICP-MS. The method enables micro-sampling of solid materials. This is the first time that the method has been applied to marine samples from archaeological collections. The analyses showed inter-tooth 87 Sr/ 86 Sr variation suggesting that different ratios can be detected in different regions of the Baltic Sea. Furthermore, the intra-tooth variation suggests possible different geographic origin or seasonal movement of seals within different regions in the Baltic Sea through their life time. The method was successfully applied to archaeological marine samples showing that: (1) the 87 Sr/ 86 Sr ivalue n marine environments is not uniform, (2) 87 Sr/ 86 Sr differences might reflect differences in ecology and life history of different seal species, and (3) archaeological mobility studies based on 87 Sr/ 86 Sr ratio in humans should therefore be evaluated together with diet reconstruction. This article is protected by copyright. All rights reserved.
Pasteris, J.D.; Chou, I.-Ming
1998-01-01
We used Raman microsampling spectroscopy (RMS) to determine the degree of crystallinity of minute (2-15 ??m) graphite inclusions in quartz in two sets of samples: experimentally reequilibrated fluid inclusions in a natural quartz grain and biotite-bearing paragneisses from the KTB deep drillhole in SE Germany. Our sequential reequilibration experiments at 725??C on initially pure CO2 inclusions in a quartz wafer and the J. Krautheim (1993) experiments at 900-1100??C on organic compounds heated in gold or platinum capsules suggest that, at a given temperature, (1) fluid-deposited graphite will have a lower crystallinity than metamorphosed organic matter and (2) that the crystallinity of fluid-deposited graphite is affected by the composition of the fluid from which it was deposited. We determined that the precipitation of more-crystalline graphite is favored by lower fH2 (higher fO2), and that the crystallinity of graphite is established by the conditions (including gas fugacities) that pertain as the fluid first reaches graphite saturation. Graphite inclusions within quartz grains in the KTB rocks show a wide range in crystallinity index, reflecting three episodes of carbon entrapment under different metamorphic conditions. Isolated graphite inclusions have the spectral properties of totally ordered, completely crystalline graphite. Such crystallinity suggests that the graphite was incorporated from the surrounding metasedimentary rocks, which underwent metamorphism at upper amphibolite-facies conditions. Much of the fluid-deposited graphite in fluid inclusions, however, shows some spectral disorder. The properties of that graphite resemble those of experimental precipitates at temperatures in excess of 700??C and at elevated pressures, suggesting that the inclusions represent precipitates from C-O-H fluids trapped under conditions near those of peak metamorphism at the KTB site. In contrast, graphite that is intimately associated with chlorite and other (presumably low-temperature) silicates in inclusions is highly disordered and spectrally resembles kerogens. This graphite probably was deposited during later greenschist-facies retrograde metamorphism at about 400-500??C. The degree of crystallinity of fluid-deposited graphite is shown to be a much more complex function of temperature than is the crystallinity of metamorphic graphite. To some extent, experiments can provide temperature-calibration of the crystallinity index. However, the difference in time scales between experimental runs and geologic processes makes it difficult to infer specific temperatures for naturally precipitated graphite. Copyright ?? 1998 Elsevier Science Ltd.
Effects of surface preparation on quality of aluminum alloy weldments
NASA Technical Reports Server (NTRS)
Kizer, D.; Saperstein, Z.
1968-01-01
Study of surface preparations and surface contamination effects on the welding of 2014 aluminum involves several methods of surface analysis to identify surface properties conducive to weld defects. These methods are radioactive evaporation, spectral reflectance mass spectroscopy, gas chromatography and spark emission spectroscopy.
Gorzsás, András; Sundberg, Björn
2014-01-01
Fourier transform infrared (FT-IR) spectroscopy is a fast, sensitive, inexpensive, and nondestructive technique for chemical profiling of plant materials. In this chapter we discuss the instrumental setup, the basic principles of analysis, and the possibilities for and limitations of obtaining qualitative and semiquantitative information by FT-IR spectroscopy. We provide detailed protocols for four fully customizable techniques: (1) Diffuse Reflectance Infrared Fourier Transform Spectroscopy (DRIFTS): a sensitive and high-throughput technique for powders; (2) attenuated total reflectance (ATR) spectroscopy: a technique that requires no sample preparation and can be used for solid samples as well as for cell cultures; (3) microspectroscopy using a single element (SE) detector: a technique used for analyzing sections at low spatial resolution; and (4) microspectroscopy using a focal plane array (FPA) detector: a technique for rapid chemical profiling of plant sections at cellular resolution. Sample preparation, measurement, and data analysis steps are listed for each of the techniques to help the user collect the best quality spectra and prepare them for subsequent multivariate analysis.
NASA Astrophysics Data System (ADS)
Potapova, E. V.; Dremin, V. V.; Zherebtsov, E. A.; Makovik, I. N.; Zharkikh, E. V.; Dunaev, A. V.; Pilipenko, O. V.; Sidorov, V. V.; Krupatkin, A. I.
2017-12-01
The possibility of a complex approach for studying changes in the system of blood microcirculation and metabolic processes in the biotissue of lower extremities using optical noninvasive methods of laser doppler flowmetry (LDF), fluorescence spectroscopy, and diffuse reflectance spectroscopy in combination with different modes of heating tests has been assessed. Seventy-six patients with type 2 diabetes mellitus, with 14 patients having visible trophic foot impairments, and 48 healthy volunteers have been examined. The parameters of LDF signals and spectra of fluorescence intensity and diffuse reflectance for foot skin have been analyzed. Statistically significant differences in the recorded parameters between the groups under study have been found. It has been concluded that combined application of noninvasive methods of spectroscopy could be used for diagnostics of complications both upon the occurrence of preliminary symptoms of diabetes, when pathological changes are still reversible, and in the presence of impairments to prevent aggravation of the disease and select an adequate correction of the treatment.
NASA Astrophysics Data System (ADS)
Cheng, Jin-ying; Xu, Liang; Lü, Guo-dong; Tang, Jun; Mo, Jia-qing; Lü, Xiao-yi; Gao, Zhi-xian
2017-01-01
A Raman spectroscopy method combined with neural network is used for the invasive and rapid detection of echinococcosis. The Raman spectroscopy measurements are performed on two groups of blood serum samples, which are from 28 echinococcosis patients and 38 healthy persons, respectively. The normalized Raman reflection spectra show that the reflectivity of the echinococcosis blood serum is higher than that of the normal human blood serum in the wavelength ranges of 101—175 nm and 1 801—2 701 nm. Then the principal component analysis (PCA) and back propagation neural network (BPNN) model are used to obtain the diagnosis results. The diagnosis rates for healthy persons and echinococcosis persons are 93.333 3% and 90.909 1%, respectively, so the average final diagnosis rate is 92.121 2%. The results demonstrate that the Raman spectroscopy analysis of blood serum combined with PCA-BPNN has considerable potential for the non-invasive and rapid detection of echinococcosis.
Darvin, Maxim E; Sandhagen, Carl; Koecher, Wolfgang; Sterry, Wolfram; Lademann, Juergen; Meinke, Martina C
2012-07-01
Based on compelling in vivo and in vitro studies on human skin, carotenoids are thought to be of great interest as powerful antioxidants acting to prevent free-radical-induced damages, including premature skin ageing and the development of skin diseases such as cancer. Among the available techniques that are suitable for noninvasive determination of carotenoids in human skin, are resonance Raman spectroscopy (RRS) and reflection spectroscopy (RS). For RS, a LED-based miniaturized spectroscopic system (MSS) was developed for noninvasive measurement of carotenoids in human skin. The optimization and subsequent calibration of the MSS was performed with the use of RRS. A strong correlation between the carotenoid concentration determined by the RS and for the RRS system was achieved for human skin in vivo (R = 0.88) and for bovine udder skin in vitro (R = 0.81). Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Classification of specialty seed meals from NIR reflectance spectra
USDA-ARS?s Scientific Manuscript database
Near infrared reflectance spectroscopy was used to identify alternative seed meals proposed for food and feed formulations. Spectra were collected from cold pressed Camelina (Camelina sativa), Coriander (Coriandrum sativum), and Pennycress (Thlaspi arvense) meals. Additional spectra were collected ...
Noninvasive glucose monitoring by optical reflective and thermal emission spectroscopic measurements
NASA Astrophysics Data System (ADS)
Saetchnikov, V. A.; Tcherniavskaia, E. A.; Schiffner, G.
2005-08-01
Noninvasive method for blood glucose monitoring in cutaneous tissue based on reflective spectrometry combined with a thermal emission spectroscopy has been developed. Regression analysis, neural network algorithms and cluster analysis are used for data processing.
NASA Astrophysics Data System (ADS)
Stelzle, Florian; Zam, Azhar; Adler, Werner; Douplik, Alexandre; Tangermann-Gerk, Katja; Nkenke, Emeka; Neukam, Friedrich Wilhelm; Schmidt, Michael
Objective: Laser surgery has many advantages. However, due to a lack of haptic feedback it is accompanied by the risk of iatrogenic nerve damage. The aim of this study was to evaluate the possibilities of optical nerve identification by diffuse reflectance spectroscopy to set the base for a feedback control system to enhance nerve preservation in oral and maxillofacial laser surgery. Materials and Methods: Diffuse reflectance spectra of nerve tissue, skin, mucosa, fat tissue, muscle, cartilage and bone (15120 spectra) of ex vivo pig heads were acquired in the wavelength range of 350-650 nm. Tissue differentiation was performed by principal components analysis (PCA) followed by linear discriminant analysis (LDA). Specificity and sensitivity were calculated by receiver operating characteristic (ROC) analysis and the area under curve (AUC). Results: Nerve tissue could correctly be identified and differed from skin, mucosa, fat tissue, muscle, cartilage and bone in more than 90% of the cases (AUC results) with a specificity of over 78% and a sensitivity of more than 86%. Conclusion: Nerve tissue can be identified by diffuse reflectance spectroscopy with high precision and reliability. The results may set the base for a feedback system to prevent iatrogenic nerve damage performing oral and maxillofacial laser surgery.
Yamamoto, Naoyuki; Kawashima, Natsumi; Kitazaki, Tomoya; Mori, Keita; Kang, Hanyue; Nishiyama, Akira; Wada, Kenji; Ishimaru, Ichiro
2018-05-01
Smart toilets could be used to monitor different components of urine in daily life for early detection of lifestyle-related diseases and prompt provision of treatment. For analysis of biological samples such as urine by midinfrared spectroscopy, thin-film samples like liquid cells are needed because of the strong absorption of midinfrared light by water. Conventional liquid cells or fixed cells are prepared based on the liquid membrane method and solution technique, but these are not quantitative and are difficult to set up and clean. We generated an ultrasonic standing wave reflection plane in a sample and produced an ultrasonic liquid cell. In this cell, the thickness of the optical path length was adjustable, as in the conventional method. The reflection plane could be generated at an arbitrary depth and internal reflected light could be detected by changing the frequency of the ultrasonic wave. We could generate refractive index boundaries using the density difference created by the ultrasonic standing wave. Creation of the reflection plane in the sample was confirmed by optical coherence tomography. Using the proposed method and midinfrared spectroscopy, we discriminated between normal urine samples spiked with glucose at different concentrations and obtained a high correlation coefficient. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).
Anderson, T. Anthony; Kang, Jeon Woong; Gubin, Tatyana; Dasari, Ramachandra R.; So, Peter T. C.
2016-01-01
BACKGROUND Neuraxial anesthesia and epidural steroid injection techniques require precise anatomical targeting to ensure successful and safe analgesia. Previous studies suggest that only some of the tissues encountered during these procedures can be identified by spectroscopic methods, and no previous study has investigated the use of Raman, diffuse reflectance, and fluorescence spectroscopies. The authors hypothesized that real-time needle-tip spectroscopy may aid epidural needle placement and tested the ability of spectroscopy to distinguish each of the tissues in the path of neuraxial needles. METHODS For comparison of detection methods, the spectra of individual, dissected ex vivo paravertebral and neuraxial porcine tissues were collected using Raman spectroscopy (RS), diffuse reflectance spectroscopy (DRS), and fluorescence spectroscopy (FS). Real-time spectral guidance was tested using a 2 mm inner diameter fiber optic probe-in-needle device. Raman spectra were collected during the needle’s passage through intact paravertebral and neuraxial porcine tissue and analyzed afterward. The RS tissue signatures were verified as mapping to individual tissue layers using histochemical staining and widefield microscopy. RESULTS Raman spectroscopy revealed a unique spectrum for all ex vivo paravertebral and neuraxial tissue layers; DRS and FS spectra were not distinct for all tissues. Moreover, when accounting for the expected order of tissues, real-time Raman spectra recorded during needle insertion also permitted identification of each paravertebral and neuraxial porcine tissue. CONCLUSIONS This study demonstrates Raman spectroscopy can distinguish the tissues encountered during epidural needle insertion. This technology may prove useful during needle placement by providing evidence of its anatomical localization. PMID:27466032
NASA Astrophysics Data System (ADS)
Suzuki, Yusuke; Maruo, Katsuhiko; Zhang, Alice W.; Shimogaki, Kazushige; Ogawa, Hideto; Hirayama, Fumiya
2012-01-01
Bacterial contamination of blood products is one of the most frequent infectious complications of transfusion. Since glucose levels in blood supplies decrease as bacteria proliferate, it should be possible to detect the presence of bacterial contamination by measuring the glucose concentrations in the blood components. Hence this study is aimed to serve as a preliminary study for the nondestructive measurement of glucose level in transfusion blood. The glucose concentrations in red blood cell (RBC) samples were predicted using near-infrared diffuse-reflectance spectroscopy in the 1350 to 1850 nm wavelength region. Furthermore, the effects of donor, hematocrit level, and temperature variations among the RBC samples were observed. Results showed that the prediction performance of a dataset which contained samples that differed in all three parameters had a standard error of 29.3 mg/dL. Multiplicative scatter correction (MSC) preprocessing method was also found to be effective in minimizing the variations in scattering patterns created by various sample properties. The results suggest that the diffuse-reflectance spectroscopy may provide another avenue for the detection of bacterial contamination in red cell concentrations (RCC) products.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gianotto, A.K.; Wichlacz, P.L.; Jolley, J.G.
1989-01-01
Thin films of copper (2.0 nm on germanium internal reflection elements (IREs) and 3.4 nm on germanium discs) were exposed to 10% gum arabic (aqueous solution), 2% alginic acid (aqueous solution), 1% bacterial culture supernatant (BCS, simulated seawater solution) and 0.5% Pseudomonas atlantica exopolymer (simulated seawater solution). The IREs were monitored in situ, in real time using fourier transform infrared/cylindrical internal reflection/attenuated total reflection spectroscopy as a function of time at ambient conditions. The discs were characterized (pre- and post-exposure) by x-ray photoelectron and Auger electron spectroscopies. Ancillary graphite furnace atomic absorption spectroscopy was used to monitor the removal processmore » of the copper thin film from the germanium substrates. Results indicate that Cu was oxidized by gum arabic, alginic acid and BCS. Furthermore, Cu was removed from the Cu/Ge interface by all four polymers. The Cu was found associated with the polymer solutions. 20 refs., 6 figs., 1 tab.« less
NASA Astrophysics Data System (ADS)
Siozos, Panagiotis; Philippidis, Aggelos; Anglos, Demetrios
2017-11-01
A novel, portable spectrometer, combining two analytical techniques, laser-induced breakdown spectroscopy (LIBS) and diffuse reflectance spectroscopy, was developed with the aim to provide an enhanced instrumental and methodological approach with regard to the analysis of pigments in objects of cultural heritage. Technical details about the hybrid spectrometer and its operation are presented and examples are given relevant to the analysis of paint materials. Both LIBS and diffuse reflectance spectra in the visible and part of the near infrared, corresponding to several neat mineral pigment samples, were recorded and the complementary information was used to effectively distinguish different types of pigments even if they had similar colour or elemental composition. The spectrometer was also employed in the analysis of different paints on the surface of an ancient pottery sherd demonstrating the capabilities of the proposed hybrid diagnostic approach. Despite its instrumental simplicity and compact size, the spectrometer is capable of supporting analytical campaigns relevant to archaeological, historical or art historical investigations, particularly when quick data acquisition is required in the context of surveys of large numbers of objects and samples.
Fuji apple storage time rapid determination method using Vis/NIR spectroscopy.
Liu, Fuqi; Tang, Xuxiang
2015-01-01
Fuji apple storage time rapid determination method using visible/near-infrared (Vis/NIR) spectroscopy was studied in this paper. Vis/NIR diffuse reflection spectroscopy responses to samples were measured for 6 days. Spectroscopy data were processed by stochastic resonance (SR). Principal component analysis (PCA) was utilized to analyze original spectroscopy data and SNR eigen value. Results demonstrated that PCA could not totally discriminate Fuji apples using original spectroscopy data. Signal-to-noise ratio (SNR) spectrum clearly classified all apple samples. PCA using SNR spectrum successfully discriminated apple samples. Therefore, Vis/NIR spectroscopy was effective for Fuji apple storage time rapid discrimination. The proposed method is also promising in condition safety control and management for food and environmental laboratories.
Fuji apple storage time rapid determination method using Vis/NIR spectroscopy
Liu, Fuqi; Tang, Xuxiang
2015-01-01
Fuji apple storage time rapid determination method using visible/near-infrared (Vis/NIR) spectroscopy was studied in this paper. Vis/NIR diffuse reflection spectroscopy responses to samples were measured for 6 days. Spectroscopy data were processed by stochastic resonance (SR). Principal component analysis (PCA) was utilized to analyze original spectroscopy data and SNR eigen value. Results demonstrated that PCA could not totally discriminate Fuji apples using original spectroscopy data. Signal-to-noise ratio (SNR) spectrum clearly classified all apple samples. PCA using SNR spectrum successfully discriminated apple samples. Therefore, Vis/NIR spectroscopy was effective for Fuji apple storage time rapid discrimination. The proposed method is also promising in condition safety control and management for food and environmental laboratories. PMID:25874818
System and technique for characterizing fluids using ultrasonic diffraction grating spectroscopy
Greenwood, Margaret S [Richland, WA
2008-07-08
A system for determining property of multiphase fluids based on ultrasonic diffraction grating spectroscopy includes a diffraction grating on a solid in contact with the fluid. An interrogation device delivers ultrasound through the solid and a captures a reflection spectrum from the diffraction grating. The reflection spectrum exhibits peaks whose relative size depends on the properties of the various phases of the multiphase fluid. For example, for particles in a liquid, the peaks exhibit dependence on the particle size and the particle volume fraction. Where the exact relationship is know know a priori, data from different peaks of the same reflection spectrum or data from the peaks of different spectra obtained from different diffraction gratings can be used to resolve the size and volume fraction.
Magnetoanisotropic spin-triplet Andreev reflection in ferromagnet-Ising superconductor junctions
NASA Astrophysics Data System (ADS)
Lv, Peng; Zhou, Yan-Feng; Yang, Ning-Xuan; Sun, Qing-Feng
2018-04-01
We theoretically study the electronic transport through a ferromagnet-Ising superconductor junction. A tight-binding Hamiltonian describing the Ising superconductor is presented. Then by combining the nonequilibrium Green's function method, the expressions of Andreev reflection coefficient and conductance are obtained. A strong magnetoanisotropic spin-triplet Andreev reflection is shown, and the magnetoanisotropic period is π instead of 2 π as in the conventional magnetoanisotropic system. We demonstrate a significant increase of the spin-triplet Andreev reflection for the single-band Ising superconductor. Furthermore, the dependence of the Andreev reflection on the incident energy and incident angle are also investigated. A complete Andreev reflection can occur when the incident energy is equal to the superconducting gap, regardless of the Fermi energy (spin polarization) of the ferromagnet. For the suitable oblique incidence, the spin-triplet Andreev reflection can be strongly enhanced. In addition, the conductance spectroscopies of both zero bias and finite bias are studied, and the influence of gate voltage, exchange energy, and spin-orbit coupling on the conductance spectroscopy are discussed in detail. The conductance exhibits a strong magnetoanisotropy with period π as the Andreev reflection coefficient. When the magnetization direction is parallel to the junction plane, a large conductance peak always emerges at the superconducting gap. This work offers a comprehensive and systematic study of the spin-triplet Andreev reflection and has an underlying application of π -periodic spin valve in spintronics.
NASA Astrophysics Data System (ADS)
Arrizabalaga, Iker; Gómez-Laserna, Olivia; Aramendia, Julene; Arana, Gorka; Madariaga, Juan Manuel
2014-08-01
This work studies the applicability of a Diffuse Reflectance Infrared Fourier Transform handheld device to perform in situ analyses on Cultural Heritage assets. This portable diffuse reflectance spectrometer has been used to characterise and diagnose the conservation state of (a) building materials of the Guevara Palace (15th century, Segura, Basque Country, Spain) and (b) different 19th century wallpapers manufactured by the Santa Isabel factory (Vitoria-Gasteiz, Basque Country, Spain) and by the well known Dufour and Leroy manufacturers (Paris, France), all of them belonging to the Torre de los Varona Castle (Villanañe, Basque Country, Spain). In all cases, in situ measurements were carried out and also a few samples were collected and measured in the laboratory by diffuse reflectance spectroscopy (DRIFT) in order to validate the information obtained by the handheld instrument. In the analyses performed in situ, distortions in the diffuse reflectance spectra can be observed due to the presence of specular reflection, showing the inverted bands caused by the Reststrahlen effect, in particular on those IR bands with the highest absorption coefficients. This paper concludes that the results obtained in situ by a diffuse reflectance handheld device are comparable to those obtained with laboratory diffuse reflectance spectroscopy equipment and proposes a few guidelines to acquire good spectra in the field, minimising the influence caused by the specular reflection.
Devpura, Suneetha; Pattamadilok, Bensachee; Syed, Zain U.; Vemulapalli, Pranita; Henderson, Marsha; Rehse, Steven J.; Hamzavi, Iltefat; Lim, Henry W.; Naik, Ratna
2011-01-01
Quantification of skin changes due to acanthosis nigricans (AN), a disorder common among insulin-resistant diabetic and obese individuals, was investigated using two optical techniques: diffuse reflectance spectroscopy (DRS) and colorimetry. Measurements were obtained from AN lesions on the neck and two control sites of eight AN patients. A principal component/discriminant function analysis successfully differentiated between AN lesion and normal skin with 87.7% sensitivity and 94.8% specificity in DRS measurements and 97.2% sensitivity and 96.4% specificity in colorimetry measurements. PMID:21698027
Electronic processes in TTF-derived complexes studied by IR spectroscopy
NASA Astrophysics Data System (ADS)
Graja, Andrzej
2001-09-01
We focus our attention on the plasma-edge-like dispersion of the reflectance spectra of the selected bis(ethylenodithio)tetrathiafulvalene (BEDT-TTF)-derived organic conductors. The standard procedure to determine the electron transport parameters in low-dimensional organic conductors consists of fitting the appropriate theoretical models with the experimental reflectance data. This procedure provides us with basic information like plasma frequency, the optical effective mass of charge carriers, their number, mean free path and damping constant. Therefore, it is concluded that the spectroscopy is a powerful tool to study the electronic processes in conducting organic solids.
Noninvasive Study of Explosive Materials by Time Domain Spectroscopy and FTIR
NASA Astrophysics Data System (ADS)
Huang, Feng; Federici, John; Gary, Dale; Barat, Robert; Zimdars, David
2005-04-01
Transmission and reflection spectroscopy in the Terahertz (THz) range (˜ 3 to 0.1 mm) is potentially useful for the detection of explosives and biological agents. This paper describes the use of THz time domain spectroscopy (TDS) applied in transmission to the 1,3,5 trinitro-s-triazine (RDX), C4, Amonium Nitrate, etc. Samples were also subjected to Fourier Transform Infrared (FTIR) spectroscopy over the same range for comparison. General agreement confirms the absorption features found. The nature of THz technology applied in the noninvasive detection of such material is discussed.
NASA Astrophysics Data System (ADS)
Bruni, Silvia; Guglielmi, Vittoria; Della Foglia, Elena; Castoldi, Marina; Bagnasco Gianni, Giovanna
2018-02-01
A study is presented based on the use of entirely non-destructive spectroscopic techniques to analyze the chemical composition of the painted surface layer of archaeological pottery. This study aims to define both the raw materials and the working technology of ancient potters. Energy-dispersive X-ray analysis, micro-Raman spectroscopy, visible and near infrared (NIR) diffuse reflection spectroscopy and external reflection Fourier-transform infrared (FTIR) spectroscopy were applied to matt-painted bichrome pottery sherds (VIII-VII century B.C.) from the site of Incoronata near Metaponto in southern Italy. Two different raw materials, ochre and iron-rich clay, were recognized for the red decoration, while the dark areas resulted to have been obtained by the so-called manganese black technique. In any case, it was demonstrated that the decoration was applied before firing, in spite of its sometimes grainy aspect that could suggest a post-firing application. For the samples with a more sophisticated decorative pattern a red/black/white polychromy was recognized, as the lighter areas correspond to an ;intentional white; obtained by the firing of a calcium-rich clay. Reflection spectroscopy in the visible-NIR and mid-IR as well as micro-Raman spectroscopy were then employed to characterize the decoration of an intact ceramic urn from the Etruscan town of Chiusi, evidencing a post-firing painting based on the use of red ochre, carbon black and lime, possibly imitating the ;fresco; technique used in wall paintings.
NASA Astrophysics Data System (ADS)
Poldi, G.; Caglio, S.
2013-06-01
The importance of identifying pigments using non invasive (n.i.) analyses has gained increasing importance in the field of spectroscopy applied to art conservation and art studies. Among the large set of pigments synthesized and marketed during 20th century, surely phthalocyanine blue and green pigments occupy an important role in the field of painting (including restoration) and printing, thanks to their characteristics like brightness and fastness. This research focused on the most used phthalocyanine blue (PB15:1 and PB15:3) and green pigments (PG7), and on the possibility to identify these organic compounds using a methodology like reflectance spectroscopy in the UV, visible and near IR range (UV-vis-NIR RS), performed easily through portable instruments. Laboratory tests and three examples carried out on real paintings are discussed.
Optical assessment of skin carotenoid status as a biomarker of vegetable and fruit intake
USDA-ARS?s Scientific Manuscript database
Resonance Raman spectroscopy (RRS) and reflection spectroscopy (RS) are optical methods applicable to the non-invasive detection of carotenoids in human skin. RRS is the older, more thoroughly validated method, whereas RS is newer and has several advantages. Since collective skin carotenoid levels...
Comparison of field and laboratory VNIR spectroscopy for profile soil property estimation
USDA-ARS?s Scientific Manuscript database
In-field, in-situ data collection with soil sensors has potential to improve the efficiency and accuracy of soil property estimates. Optical diffuse reflectance spectroscopy (DRS) has been used to estimate important soil properties, such as soil carbon, nitrogen, water content, and texture. Most pre...
Electro-Optical Characterization | Photovoltaic Research | NREL
Applications Detection Range Temperature Range Non-Destructive? Image/ Mapping? Photoluminescence spectroscopy Determine bandgap, material quality. Identify defects. 0.4-2.7 µm 4-300 K Yes Yes Minority-carrier lifetime distributions in silicon wafers. 103 to 108 defects/cm2 Room temperature No Yes Reflectance spectroscopy
Detection of starch adulteration in onion powder by FT-NIR and FT-IR spectroscopy
USDA-ARS?s Scientific Manuscript database
Adulteration of onion powder with cornstarch was identified by Fourier transform near-infrared (FT-NIR) and Fourier transform infrared (FT-IR) spectroscopy. The reflectance spectra of 180 pure and adulterated samples (1–35 wt% starch) were collected and preprocessed to generate calibration and predi...
Onga, Chie; Nakashima, Satoru
2014-01-01
Visible darkfield reflectance spectroscopy equipped with a color mapping system has been developed and applied to a brown-colored Rokko granite sample. Sample reflectance spectra converted to Kubelka-Munk (KM) spectra show similar features to goethite and lepidocrocite. Raman microspectroscopy on the granite sample surface confirms the presence of these minerals. Here, L*a*b* color values (second Commission Internationale d'Eclairage [CIELab] 1976 color space) were determined from the sample reflection spectra. Grey, yellow, and brown zones of the granite show different L*, a*, and b* values. In the a*-b* diagram, a* and b* values in the grey and brown zones are on the lepidocrocite/ferrihydrite trends, but their values in the brown zone are larger than those in the grey zone. The yellow zone shows data points close to the goethite trend. Iron (hydr)oxide-rich areas can be visualized by means of large a* and b* values in the L*, a*, and b* maps. Although the present method has some problems and limitations, the visible darkfield reflectance spectroscopy can be a useful method for colored-material characterization.
Noninvasive blood glucose sensing on human body with near-infrared reflection spectroscopy
NASA Astrophysics Data System (ADS)
Huang, Zhen-hao; Hao, Chang-ning; Zhang, Lin-lin; Huang, Yan-chao; Shi, Yi-qin; Jiang, Geng-ru; Duan, Jun-li
2011-08-01
The non-invasive blood glucose sensing method has shown its high impact on the clinic application. This can make the measurement on the clinically relevant concentrations of glucose be free from the pain of patient. The transmission spectrum study indicates that the dependence of glucose concentration on the absorbance is in linear manner for the glucose concentration in the region of 30mg/dL to 4.5×104mg/dL. By the near infrared reflection spectroscopy of fiber spectrometer, the reflection band between 1.2μm and 1.35μm can be used to correlated with the glucose concentration in the range of 30 to 300 mg/dL. This reflection band is finally used to measure the glucose concentration effect in non-invasive manner, which gives the statistical significance of P value 0.02. Our experiment result shows that it is possible to get the glucose concentration by the near infrared reflection spectrum measurement on the human forefinger. This non-invasive blood glucose sensing method may useful in clinic after more experiment for different people.
NASA Astrophysics Data System (ADS)
Peltre, Clement; Bruun, Sander; Du, Changwen; Stoumann Jensen, Lars
2014-05-01
The persistence of soil organic matter (SOM) is recognized as a major ecosystem property due to its key role in earth carbon cycling, soil quality and ecosystem services. SOM stability is typically studied using biological methods such as measuring CO2-C evolution from microbial decomposition of SOM during laboratory incubation or by physical or chemical fractionation methods, allowing the separation of a labile fraction of SOM. However these methods are time consuming and there is still a need for developing reliable techniques to characterize SOM stability, providing both quantitative measurements and qualitative information, in order to improve our understanding of the mechanisms controlling SOM persistence. Several spectroscopic techniques have been used to characterize and predict SOM stability, such as near infrared reflectance spectroscopy (NIRS) and diffuse reflectance mid-infrared spectroscopy (DRIFT). The latter allows a proper identification of spectral regions corresponding to vibrations of specific molecular or functional groups associated with SOM lability. However, reflectance spectroscopy for soil analyses raises some difficulties related to the low reflectance of soils, and to the high influence of particle size. In the last three decades, the progresses in microphone sensitivity dramatically increased the performance of photoacoustic Fourier transform mid-infrared spectroscopy (FTIR-PAS). This technique offers benefits over reflectance spectroscopy techniques, because particle size and the level of sample reflectance have little effect of on the PAS signal, since FTIR-PAS is a direct absorption technique. Despite its high potential for soil analysis, only a limited number of studies have so far applied FTIR-PAS for soil characterization and its potential for determining SOM degradability still needs to be investigated. The objective of this study was to assess the potential of FTIR-PAS for the characterization of SOM decomposability during laboratory incubation and more classical soil parameters such as carbon and clay content for a range of 36 soils collected from various field experiments in Denmark. Partial least square (PLS) regression was used to correlate the collected FTIR-PAS spectra with the proportion of soil organic carbon mineralized after 34 weeks of incubation at 15° C and pF 2, taken as an indicator of the labile fraction of SOM. Results showed that it is possible to predict the labile fraction of SOM with FTIR PAS with similar accuracy as with NIRS (assessed in a previous study on the same soil set). FTIR-PAS offered the advantage over NIRS to allow identification of the chemical compounds positively or negatively correlated with the labile fraction of SOM. The band at 1612 cm-1 corresponding to polysaccharides, pectin and aromatic C=C was the band most positively correlated with labile SOM, which we attributed to the relative lability of fresh plant debris rich in polysaccharide and aromatic lignin. The band at 1560-1590 cm-1 assigned to N=H, C=N and aromatic C=C vibration was the band most negatively correlated with the labile fraction of SOM, confirming the abundance of nitrogenous and aromatic compounds in stabilized SOM. In conclusion, FTIR-PAS has proved to be a powerful tool to characterize the labile fraction of SOM, offering several benefits over reflectance spectroscopy techniques.
Stevens, Antoine; Nocita, Marco; Tóth, Gergely; Montanarella, Luca; van Wesemael, Bas
2013-01-01
Soil organic carbon is a key soil property related to soil fertility, aggregate stability and the exchange of CO2 with the atmosphere. Existing soil maps and inventories can rarely be used to monitor the state and evolution in soil organic carbon content due to their poor spatial resolution, lack of consistency and high updating costs. Visible and Near Infrared diffuse reflectance spectroscopy is an alternative method to provide cheap and high-density soil data. However, there are still some uncertainties on its capacity to produce reliable predictions for areas characterized by large soil diversity. Using a large-scale EU soil survey of about 20,000 samples and covering 23 countries, we assessed the performance of reflectance spectroscopy for the prediction of soil organic carbon content. The best calibrations achieved a root mean square error ranging from 4 to 15 g C kg(-1) for mineral soils and a root mean square error of 50 g C kg(-1) for organic soil materials. Model errors are shown to be related to the levels of soil organic carbon and variations in other soil properties such as sand and clay content. Although errors are ∼5 times larger than the reproducibility error of the laboratory method, reflectance spectroscopy provides unbiased predictions of the soil organic carbon content. Such estimates could be used for assessing the mean soil organic carbon content of large geographical entities or countries. This study is a first step towards providing uniform continental-scale spectroscopic estimations of soil organic carbon, meeting an increasing demand for information on the state of the soil that can be used in biogeochemical models and the monitoring of soil degradation.
Stevens, Antoine; Nocita, Marco; Tóth, Gergely; Montanarella, Luca; van Wesemael, Bas
2013-01-01
Soil organic carbon is a key soil property related to soil fertility, aggregate stability and the exchange of CO2 with the atmosphere. Existing soil maps and inventories can rarely be used to monitor the state and evolution in soil organic carbon content due to their poor spatial resolution, lack of consistency and high updating costs. Visible and Near Infrared diffuse reflectance spectroscopy is an alternative method to provide cheap and high-density soil data. However, there are still some uncertainties on its capacity to produce reliable predictions for areas characterized by large soil diversity. Using a large-scale EU soil survey of about 20,000 samples and covering 23 countries, we assessed the performance of reflectance spectroscopy for the prediction of soil organic carbon content. The best calibrations achieved a root mean square error ranging from 4 to 15 g C kg−1 for mineral soils and a root mean square error of 50 g C kg−1 for organic soil materials. Model errors are shown to be related to the levels of soil organic carbon and variations in other soil properties such as sand and clay content. Although errors are ∼5 times larger than the reproducibility error of the laboratory method, reflectance spectroscopy provides unbiased predictions of the soil organic carbon content. Such estimates could be used for assessing the mean soil organic carbon content of large geographical entities or countries. This study is a first step towards providing uniform continental-scale spectroscopic estimations of soil organic carbon, meeting an increasing demand for information on the state of the soil that can be used in biogeochemical models and the monitoring of soil degradation. PMID:23840459
Infrared Microtransmission And Microreflectance Of Biological Systems
NASA Astrophysics Data System (ADS)
Hill, Steve L.; Krishnan, K.; Powell, Jay R.
1989-12-01
The infrared microsampling technique has been successfully applied to a variety of biological systems. A microtomed tissue section may be prepared to permit both visual and infrared discrimination. Infrared structural information may be obtained for a single cell, and computer-enhanced images of tissue specimens may be calculated from spectral map data sets. An analysis of a tissue section anomaly may gg suest eitherprotein compositional differences or a localized concentration of foreign matterp. Opaque biological materials such as teeth, gallstones, and kidney stones may be analyzed by microreflectance spectroscop. Absorption anomalies due to specular dispersion are corrected with the Kraymers-Kronig transformation. Corrected microreflectance spectra may contribute to compositional analysis and correlate diseased-related spectral differences to visual specimen anomalies.
In vivo sodium, potassium, and sperm concentrations in the rat epididymis.
Turner, T T; Hartmann, P K; Howards, S S
1977-02-01
In vivo samples of epididymal fluids were obtained through the use of micropuncture techniques. Microsamples from four areas of the rat epididymis were analyzed for Na+ and K+ concentrations and for sperm density. Na+ values declined significantly from caput to corpus epididymidis (P less than 0.01), while K+ and sperm concentrations increased significantly (P less than 0.01). A large water loss from the epididymal lumen was calculated, as well as net losses of both cations. Water losses may be explained on the basis of an active Na+ pump; however, the effect of the absolute values of epididymal Na+ and K+ concentrations on sperm motility and fertility remains unresolved.
Shi, C; Gao, S; Gun, S
1997-06-01
The sample is digested with 6% NaOH solution and an amount of 50 microl is used for protein content analysis by the method of Comassie Brilliant Blue G250, the residual is diluted with equal 0.4% Lathanurm-EDTA solution. Its Calcium magensium and potassium content are determined by AAS. With quick-pulsed nebulization technique. When a self-made micro-sampling device is used, 20microl of sample volume is needed and it is only the 1/10 approximately 1/20 of the sample volume required for conventional determination. Sensitivity, precision and rate of recovery agree well with those using regular wet ashing method.
Monitoring the in-situ oxide growth on uranium by ultraviolet-visible reflectance spectroscopy
NASA Astrophysics Data System (ADS)
Schweke, Danielle; Maimon, Chen; Chernia, Zelig; Livneh, Tsachi
2012-11-01
We demonstrate the in-situ monitoring of oxide growth on U-0.1 wt. % Cr by means of UV-visible reflectance spectroscopy in the thickness range of ˜20-150 nm. Two different approaches are presented: In the "modeling approach," we employ a model for a metallic substrate covered by a dielectric layer, while taking into account the buildup of oxygen gradient and surface roughness. Then, we fit the simulated spectra to the experimental one. In the "extrema analysis," we derive an approximated analytical expression, which relates the oxide thickness to the position of the extrema in the reflectance spectra based on the condition for optical interference of the reflected light. Good agreement is found between the values extracted by the two procedures. Activation energy of ˜21 kcal/mole was obtained by monitoring the oxide growth in the temperature range of 22-90 °C. The upper bound for the thickness determination is argued to be mostly dictated by cracking and detachment processes in the formed oxide.
Lim, Jongguk; Kim, Giyoung; Mo, Changyeun; Oh, Kyoungmin; Yoo, Hyeonchae; Ham, Hyeonheui; Kim, Moon S.
2017-01-01
The purpose of this study is to use near-infrared reflectance (NIR) spectroscopy equipment to nondestructively and rapidly discriminate Fusarium-infected hulled barley. Both normal hulled barley and Fusarium-infected hulled barley were scanned by using a NIR spectrometer with a wavelength range of 1175 to 2170 nm. Multiple mathematical pretreatments were applied to the reflectance spectra obtained for Fusarium discrimination and the multivariate analysis method of partial least squares discriminant analysis (PLS-DA) was used for discriminant prediction. The PLS-DA prediction model developed by applying the second-order derivative pretreatment to the reflectance spectra obtained from the side of hulled barley without crease achieved 100% accuracy in discriminating the normal hulled barley and the Fusarium-infected hulled barley. These results demonstrated the feasibility of rapid discrimination of the Fusarium-infected hulled barley by combining multivariate analysis with the NIR spectroscopic technique, which is utilized as a nondestructive detection method. PMID:28974012
Takeda, Kohsuke; Norisuye, Tomohisa; Tran-Cong-Miyata, Qui
2013-07-01
Multi-echo reflection ultrasound spectroscopy (MERUS), which enables one to simultaneously evaluate the attenuation coefficient α, the sound velocity v and the density ρ, has been developed for measurements of elastic moduli. In the present study, the technique was further developed to analyze systems undergoing gelation where an unphysical decrease in the apparent density was previously observed after polymerization. The main reason for this problem was that the shrinkage accompanying the gelation led to a small gap between the cell wall and the sample, resulting in the superposition of the reflected signals which were not separable into individual components. By taking into account the multiply reflecting echoes at the interface of the gap, the corrected densities were systematically obtained and compared with the results for the floating test. The present technique opens a new route to simultaneously evaluate the three parameters α, v and ρ and also the sample thickness for solid thin films. Copyright © 2013 Elsevier B.V. All rights reserved.
Tunable near- to mid-infrared pump terahertz probe spectroscopy in reflection geometry
NASA Astrophysics Data System (ADS)
Zhang, S. J.; Wang, Z. X.; Dong, T.; Wang, N. L.
2017-10-01
Strong-field mid-infrared pump-terahertz (THz) probe spectroscopy has been proven as a powerful tool for light control of different orders in strongly correlated materials. We report the construction of an ultrafast broadband infrared pump-THz probe system in reflection geometry. A two-output optical parametric amplifier is used for generating mid-infrared pulses with GaSe as the nonlinear crystal. The setup is capable of pumping bulk materials at wavelengths ranging from 1.2 μm to 15 μm and beyond, and detecting the subtle, transient photoinduced changes in the reflected electric field of the THz probe at different temperatures. As a demonstration, we present 15 μm pump-THz probe measurements of a bulk EuSbTe3 single crystal. A 0:5% transient change in the reflected THz electric field can be clearly resolved. The widely tuned pumping energy could be used in mode-selective excitation experiments and applied to many strongly correlated electron systems.
Angle-resolved reflection spectroscopy of high-quality PMMA opal crystal
NASA Astrophysics Data System (ADS)
Nemtsev, Ivan V.; Tambasov, Igor A.; Ivanenko, Alexander A.; Zyryanov, Victor Ya.
2018-02-01
PMMA opal crystal was prepared by a simple hybrid method, which includes sedimentation, meniscus formation and evaporation. We investigated three surfaces of this crystal by angle-resolved reflective light spectroscopy and SEM study. The angle-resolved reflective measurements were carried out in the 400-1100 nm range. We have determined the high-quality ordered surface of the crystal region. Narrow particle size distribution of the surface has been revealed. The average particle diameter obtained with SEM was nearly 361 nm. The most interesting result was that reflectivity of the surface turned out up to 98% at normal light incidence. Using a fit of dependences of the maximum reflectivity wavelength from an angle based on the Bragg-Snell law, the wavelength of maximum 0° reflectivity, the particle diameter and the fill factor have been determined. For the best surface maximum reflectivity wavelength of a 0° angle was estimated to be 869 nm. The particle diameter and fill factor were calculated as 372 nm and 0.8715, respectively. The diameter obtained by fitting is in excellent agreement with the particle diameter obtained with SEM. The reflectivity maximum is assumed to increase significantly when increasing the fill factor. We believe that using our simple approach to manufacture PMMA opal crystals will significantly increase the fabrication of high-quality photonic crystal templates and thin films.
ERIC Educational Resources Information Center
Pezzolo, Alessandra De Lorenzi
2011-01-01
The diffuse reflectance infrared Fourier transform (DRIFT) spectra of sand samples exhibit features reflecting their composition. Basic multivariate analysis (MVA) can be used to effectively sort subsets of homogeneous specimens collected from nearby locations, as well as pointing out similarities in composition among sands of different origins.…
USDA-ARS?s Scientific Manuscript database
NIR spectroscopy was used to measure the moisture concentration of wood pellets. Pellets were conditioned to various moisture levels between 0.63and 14.16percent (wet basis) and the moisture concentration was verified using a standard oven method. Samples from the various moisture levels were separa...
USDA-ARS?s Scientific Manuscript database
Our presentation will focus on continuing efforts to examine secondary cell wall development in cotton fibers using infrared Spectroscopy. Cotton fibers harvested at 18, 20, 24, 28, 32, 36 and 40 days after flowering were examined using attenuated total reflection Fourier transform-infrared (ATR FT-...
Gómora-Herrera, Diana; Navarrete Bolaños, Juan; Lijanova, Irina V; Olivares-Xometl, Octavio; Likhanova, Natalya V
2018-04-01
The effects exerted by the adsorption of vapors of a non-polar compound (deuterated benzene) and a polar compound (water) on the surface of Ottawa sand and a sample of reservoir sand (Channel), which was previously impregnated with silicon oil or two kinds of surfactants, (2-hydroxyethyl) trimethylammonium oleate (HETAO) and (2-hydroxyethyl)trimethylammonium azelate (HETAA), were studied by diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS) and thermogravimetric analysis (TGA). The surface chemistry of the sandstone rocks was elucidated by X-ray photoelectron spectroscopy (XPS) and scanning electron microscopy (SEM) with energy dispersive X-ray spectroscopy (EDX). Terminal surface groups such as hydroxyls can strongly adsorb molecules that interact with these surface groups (surfactants), resulting in a wettability change. The wettability change effect suffered by the surface after treating it with surfactants was possible to be detected by the DRIFTS technique, wherein it was observed that the surface became more hydrophobic after being treated with silicon oil and HETAO; the surface became more hydrophilic after treating it with HETAA.
The Evolution of Silica Nanoparticle-polyester Coatings on Surfaces Exposed to Sunlight.
Truong, Vi Khanh; Stefanovic, Miljan; Maclaughlin, Shane; Tobin, Mark; Vongsvivut, Jitraporn; Al Kobaisi, Mohammad; Crawford, Russell J; Ivanova, Elena P
2016-10-11
Corrosion of metallic surfaces is prevalent in the environment and is of great concern in many areas, including the military, transport, aviation, building and food industries, amongst others. Polyester and coatings containing both polyester and silica nanoparticles (SiO2NPs) have been widely used to protect steel substrata from corrosion. In this study, we utilized X-ray photoelectron spectroscopy, attenuated total reflection infrared micro-spectroscopy, water contact angle measurements, optical profiling and atomic force microscopy to provide an insight into how exposure to sunlight can cause changes in the micro- and nanoscale integrity of the coatings. No significant change in surface micro-topography was detected using optical profilometry, however, statistically significant nanoscale changes to the surface were detected using atomic force microscopy. Analysis of the X-ray photoelectron spectroscopy and attenuated total reflection infrared micro-spectroscopy data revealed that degradation of the ester groups had occurred through exposure to ultraviolet light to form COO·, -H2C·, -O·, -CO· radicals. During the degradation process, CO and CO2 were also produced.
Zarnowiec, Paulina; Mizera, Andrzej; Chrapek, Magdalena; Urbaniak, Mariusz; Kaca, Wieslaw
2016-07-01
Proteus spp. strains are some of the most important pathogens associated with complicated urinary tract infections and bacteremia affecting patients with immunodeficiency and long-term urinary catheterization. For epidemiological purposes, various molecular typing methods have been developed for this pathogen. However, these methods are labor intensive and time consuming. We evaluated a new method of differentiation between strains. A collection of Proteus spp. strains was analyzed by attenuated total reflectance Fourier transform infrared (ATR FT-IR) spectroscopy in the mid-infrared region. ATR FT-IR spectroscopy used in conjunction with a diamond ATR accessory directly produced the biochemical profile of the surface chemistry of bacteria. We conclude that a combination of ATR FT-IR spectroscopy and mathematical modeling provides a fast and reliable alternative for discrimination between Proteus isolates, contributing to epidemiological research. © The Author(s) 2016.
BiOBr microspheres for photocatalytic degradation of an anionic dye
NASA Astrophysics Data System (ADS)
Mera, Adriana C.; Váldes, Héctor; Jamett, Fabiola J.; Meléndrez, M. F.
2017-03-01
BiOBr microspheres were obtained using a solvothermal synthesis route in the presence of ethylene glycol and KBr at 145 °C, for 18 h. BiOBr microspheres were characterized by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS), transmission electron microscopy (TEM), X-ray diffraction (XRD), thermogravimetric analysis (TGA), nitrogen adsorption-desorption isotherms analysis, diffuse reflectance spectroscopy (DRS), and diffuse reflectance infrared Fourier transform spectroscopy (DRIFTS). Additionally, the theoretical and experimental isoelectric points (IEP) of BiOBr nanostructured microspheres were determined, and pH's influence on the degradation of an anionic dye (methyl orange) under simulated solar radiation was analyzed. Results show that 97% of methyl orange is removed at pH 2 after 60 min of photocatalytic reaction. Finally, DRIFTS studies permit the proposal of a surface reaction mechanism of the photocatalytic oxidation of MO using BiOBr microspheres.
Diffuse reflectance spectroscopy of liver tissue
NASA Astrophysics Data System (ADS)
Reistad, Nina; Nilsson, Jan; Vilhelmsson Timmermand, Oskar; Sturesson, Christian; Andersson-Engels, Stefan
2015-06-01
Diffuse reflectance spectroscopy (DRS) with a fiber-optic contact probe is a cost-effective, rapid, and non-invasive optical method used to extract diagnosis information of tissue. By combining commercially available VIS- and NIR-spectrometers with various fiber-optic contact-probes, we have access to the full wavelength range from around 400 to 1600 nm. Using this flexible and portable spectroscopy system, we have acquired ex-vivo DRS-spectra from murine, porcine, and human liver tissue. For extracting the tissue optical properties from the measured spectra, we have employed and compared predictions from two models for light propagation in tissue, diffusion theory model (DT) and Monte Carlo simulations (MC). The focus in this work is on the capacity of this DRS-technique in discriminating metastatic tumor tissue from normal liver tissue as well as in assessing and characterizing damage to non-malignant liver tissue induced by preoperative chemotherapy for colorectal liver metastases.
Point-contact Andreev reflection spectroscopy on Bi 2 Se 3 single crystals
DOE Office of Scientific and Technical Information (OSTI.GOV)
Granstrom, C. R.; Fridman, I.; Lei, H. -C.
In order to study how Andreev reflection (AR) occurs between a superconductor and a three-dimensional topological insulator (TI), we use superconducting Nb tips to perform point-contact AR spectroscopy at 4.2 K on as-grown single crystals of Bi 2Se 3. Scanning tunneling spectroscopy and scanning tunneling microscopy are also used to characterize the superconducting tip and both the doping level and surface condition of the TI sample. Furthermore, the point-contact measurements show clear spectral signatures of AR, as well as a depression of zero-bias conductance with decreasing junction impedance. The latter observation can be attributed to interfacial Rashba spin-orbit coupling, andmore » the presence of bulk bands at the Fermi level in our samples suggests that bulk states of Bi2Se3 are involved in the observed AR.« less
Point-contact Andreev reflection spectroscopy on Bi 2 Se 3 single crystals
Granstrom, C. R.; Fridman, I.; Lei, H. -C.; ...
2016-04-27
In order to study how Andreev reflection (AR) occurs between a superconductor and a three-dimensional topological insulator (TI), we use superconducting Nb tips to perform point-contact AR spectroscopy at 4.2 K on as-grown single crystals of Bi 2Se 3. Scanning tunneling spectroscopy and scanning tunneling microscopy are also used to characterize the superconducting tip and both the doping level and surface condition of the TI sample. Furthermore, the point-contact measurements show clear spectral signatures of AR, as well as a depression of zero-bias conductance with decreasing junction impedance. The latter observation can be attributed to interfacial Rashba spin-orbit coupling, andmore » the presence of bulk bands at the Fermi level in our samples suggests that bulk states of Bi2Se3 are involved in the observed AR.« less
NASA Technical Reports Server (NTRS)
Chemtob, S. M.; Arvidson, R. E.; Fernandez-Remolar, D. C.; Amils, R.; Morris, R. V.; Ming, D. W.; Prieto-Ballesteros, O.; Mustard, J. F.; Hutchinson, L.; Stein, T. C.;
2006-01-01
OMEGA recently identified spectral signatures of kieserite, gypsum, and other polyhydrated sulfates at multiple locations on the surface of Mars [1,2]. The presence of sulfates was confirmed through in situ spectroscopy by MER Opportunity [3]. An approach to validate these interpretations is to collect corresponding spectral data from sulfate-rich terrestrial analog sites. The northern Rio Tinto Valley near Nerva, Spain, is a good Martian analog locale because it features extensive seasonal sulfate mineralization driven by highly acidic waters [4]. We report on mineralogical compositions identified by field VNIR spectroscopy and laboratory Raman spectroscopy.
NASA Astrophysics Data System (ADS)
Fontaine, Norman Henry
1997-10-01
Techniques which can be used to obtain depth-resolved information on the thermodynamics at polymer-polymer and polymer-wall interfaces, and of small molecule diffusion in polymers, are of particular interest to industry. Optical methods which are sensitive to molecular vibrations (such as internal reflection Raman spectroscopy) are advantageous because they can non- destructively probe molecular content, orientation, and polarity of the local environment in a sample. However, while optical internal reflection depth-profiling methods have been reported, they have never progressed beyond the demonstration stage. In this work, the theory and methodology of internal reflection spectroscopy are developed and optimized into a rigorous field-controlled spectroscopic technique. A novel asymmetric internal reflection element (IRE) is introduced which traps back-reflections, allowing precise evanescent and standing wave probe-field control in the sample for all angles of incidence. It is demonstrated that a Gaussian laser beam will best approximate an infinite homogeneous plane wave when the IRE/sample interface lies in the paraxial-Fraunhofer region (far- field) of the beam path. Calibration methods are presented, sources of systematic errors are identified, and the angular resolution limit (ARL) is introduced as a measure of the field control developed in a sample by any internal reflection method. A general model of Raman scattering and photon detection from multi-layer thin films is developed. A new and generalized operator based transfer matrix method is developed and applied to electromagnetic field and diffusion computations in multi-layer systems. Total internal reflection spectroscopy is extended to include sub-critical angles of incidence, where resonant field enhancements generate large and selective amplification of the probe-field intensity within the layers of the sample. Fitting these resonances to the model spectral intensities allows unique determination of the location of buried interfaces in micron-sized polymer multi-layers with nanometer scale precision and the refractive indices of the layers with precision of /Delta n/approx/pm 0.0001. The Raman active molecular content of each optically distinct layer of the film is determinable simultaneously with the optical properties. Resonant mode VAIRRS studies of poly(methyl methacrylate) films spun-cast from toluene and then dried under ambient conditions have shown evidence for toluene diffusion concurrent with a rotationally hindered relaxation of oriented ester side groups about the polymer backbone. Low temperature annealing (≈87oC) has shown evidence that this hindered rotational relaxation may be reversible. VAIRRS study of a polystyrene/poly(methyl methacrylate) bi-layer has detected evidence for toluene diffusion across the buried polymer-polymer interface.
Krishtop, Victor; Doronin, Ivan; Okishev, Konstantin
2012-11-05
Photon correlation spectroscopy is an effective method for measuring nanoparticle sizes and has several advantages over alternative methods. However, this method suffers from a disadvantage in that its measuring accuracy reduces in the presence of convective flows of fluid containing nanoparticles. In this paper, we propose a scheme based on attenuated total reflectance in order to reduce the influence of convection currents. The autocorrelation function for the light-scattering intensity was found for this case, and it was shown that this method afforded a significant decrease in the time required to measure the particle sizes and an increase in the measuring accuracy.
NASA Technical Reports Server (NTRS)
Jones, W. R.; Lauer, J. L.
1979-01-01
Attenuated total reflection infrared spectroscopy was used to analyze ultrahigh molecular weight polyethylene wear test specimens. Three different specimens were analyzed. One specimen was gamma irradiated to a dose of 5.0 MRad, another to a dose of 2.5 MRad, and the final specimen was unirradiated. There was no conclusive evidence of chemical changes (i.e., unsaturation or oxidation) in the surface regions of any of the polyethylene samples. Therefore, it was concluded that the gamma irradiation sterilization procedure shoud not alter the boundary lubricating properties of the polyethylene.
UV-Vis reflection spectroscopy under variable angle incidence at the air-liquid interface.
Roldán-Carmona, Cristina; Rubia-Payá, Carlos; Pérez-Morales, Marta; Martín-Romero, María T; Giner-Casares, Juan J; Camacho, Luis
2014-03-07
The UV-Vis reflection spectroscopy (UV-Vis-RS) in situ at the air-liquid interface provides information about tilt and aggregation of chromophores in Langmuir monolayers. This information is particularly important given in most cases the chromophore is located at the polar region of the Langmuir monolayer. This region of the Langmuir monolayers has been hardly accessible by other experimental techniques. In spite of its enormous potential, the application of UV-Vis-RS has been limited mainly to reflection measurements under light normal incidence or at lower incidence angles than the Brewster angle. Remarkably, this technique is quite sensitive to the tilt of the chromophores at values of incidence angles close to or larger than the Brewster angle. Therefore, a novel method to obtain the order parameter of the chromophores at the air-liquid interface by using s- and p-polarized radiation at different incidence angles is proposed. This method allowed for the first time the experimental observation of the two components with different polarization properties of a single UV-Vis band at the air-liquid interface. The method of UV-Vis spectroscopy under variable angle incidence is presented as a new tool for obtaining rich detailed information on Langmuir monolayers.
Tarquini, Gabriele; Nunziante Cesaro, Stella; Campanella, Luigi
2014-01-01
The application of Fourier Transform InfraRed (FTIR) spectroscopy to the analysis of oil residues in fragments of archeological amphorae (3rd century A.D.) from Monte Testaccio (Rome, Italy) is reported. In order to check the possibility to reveal the presence of oil residues in archeological pottery using microinvasive and\\or not invasive techniques, different approaches have been followed: firstly, FTIR spectroscopy was used to study oil residues extracted from roman amphorae. Secondly, the presence of oil residues was ascertained analyzing microamounts of archeological fragments with the Diffuse Reflectance Infrared Spectroscopy (DRIFT). Finally, the external reflection analysis of the ancient shards was performed without preliminary treatments evidencing the possibility to detect oil traces through the observation of the most intense features of its spectrum. Incidentally, the existence of carboxylate salts of fatty acids was also observed in DRIFT and Reflectance spectra of archeological samples supporting the roman habit of spreading lime over the spoil heaps. The data collected in all steps were always compared with results obtained on purposely made replicas. © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Kaplan, H. H.; Milliken, R.
2014-12-01
Laboratory, field-, and satellite-based visible-near infrared reflectance spectroscopy allows for rapid, remote, and non-destructive analysis of geologic materials to identify mineralogy as well as organic compounds. This type of analysis has potential to aid the search for organics on Mars as a means of first detection of reduced carbon, or to study organic matter nondestructively in valuable samples such as meteorites. In order to assess potential applications of this method we aim to answer fundamental questions about detection limits and quantification of organic matter using reflectance spectroscopy. Laboratory mixtures and natural samples are measured for total organic carbon (TOC in wt.%) with standard methods and reflectance spectroscopy. Absorption features due to C-H2 and C-H3 bonds are observed in the 3.3 to 3.5μm (3000 to 2850 cm-1) wavelength region. A strong H2O feature near 3μm, as well as carbonate-related absorptions near 3.4µm, are also found in this spectral region and can complicate detection of organic material, particularly at low TOC values. In natural samples without carbonate there appears to be a linear trend between TOC and the band depth of organic absorptions; samples that have low albedo, or strong 3μm water features deviate from this trend line. Spectra of samples with carbonate may be modeled with Gaussians to remove the influence of the carbonate features and better match the organic absorption trend. Early results indicate that quantification of organic matter in natural fine-grained samples using reflectance spectroscopy will need to take low-albedo components and water content into account. Detection limits may also depend on these properties; organic absorption features are clearly seen in the lowest TOC sample measured so far (0.08wt% or 800ppm), which is a relatively bright, carbonate-free, quartz- and clay-dominated outcrop sample. A series of laboratory experiments have been undertaken in which known amounts of organic compounds are mixed with smectitic clay in order to understand detection limits and the effects of albedo and hydration in a controlled setting. These laboratory results are compared with findings from natural samples that represent a wide range of ages and depositional settings.
Arrizabalaga, Iker; Gómez-Laserna, Olivia; Aramendia, Julene; Arana, Gorka; Madariaga, Juan Manuel
2014-08-14
This work studies the applicability of a Diffuse Reflectance Infrared Fourier Transform handheld device to perform in situ analyses on Cultural Heritage assets. This portable diffuse reflectance spectrometer has been used to characterise and diagnose the conservation state of (a) building materials of the Guevara Palace (15th century, Segura, Basque Country, Spain) and (b) different 19th century wallpapers manufactured by the Santa Isabel factory (Vitoria-Gasteiz, Basque Country, Spain) and by the well known Dufour and Leroy manufacturers (Paris, France), all of them belonging to the Torre de los Varona Castle (Villanañe, Basque Country, Spain). In all cases, in situ measurements were carried out and also a few samples were collected and measured in the laboratory by diffuse reflectance spectroscopy (DRIFT) in order to validate the information obtained by the handheld instrument. In the analyses performed in situ, distortions in the diffuse reflectance spectra can be observed due to the presence of specular reflection, showing the inverted bands caused by the Reststrahlen effect, in particular on those IR bands with the highest absorption coefficients. This paper concludes that the results obtained in situ by a diffuse reflectance handheld device are comparable to those obtained with laboratory diffuse reflectance spectroscopy equipment and proposes a few guidelines to acquire good spectra in the field, minimising the influence caused by the specular reflection. Copyright © 2014 Elsevier B.V. All rights reserved.
Citartan, Marimuthu; Gopinath, Subash C B; Tominaga, Junji; Chen, Yeng; Tang, Thean-Hock
2014-08-01
Label-free-based detection is pivotal for real-time monitoring of biomolecular interactions and to eliminate the need for labeling with tags that can occupy important binding sites of biomolecules. One simplest form of label-free-based detection is ultraviolet-visible-near-infrared (UV-vis-NIR) spectroscopy, which measure changes in reflectivity as a means to monitor immobilization and interaction of biomolecules with their corresponding partners. In biosensor development, the platform used for the biomolecular interaction should be suitable for different molecular recognition elements. In this study, gold (Au)-coated polycarbonate was used as a platform and as a proof-of-concept, erythropoietin (EPO), a doping substance widely abused by the athletes was used as the target. The interaction of EPO with its corresponding molecular recognition elements (anti-EPO monoclonal antibody and anti-EPO DNA aptamer) is monitored by UV-vis-NIR spectroscopy. Prior to this, to show that UV-vis-NIR spectroscopy is a suitable method for measuring biomolecular interaction, the interaction between biotin and streptavidin was demonstrated via this strategy and reflectivity of this interaction decreased by 25%. Subsequent to this, interaction of the EPO with anti-EPO monoclonal antibody and anti-EPO DNA aptamer resulted in the decrease of reflectivity by 5% and 10%, respectively. The results indicated that Au-coated polycarbonate could be an ideal biosensor platform for monitoring biomolecular interactions using UV-vis-NIR spectroscopy. A smaller version of the Au-coated polycarbonate substrates can be derived from the recent set-up, to be applied towards detecting EPO abuse among atheletes. Copyright © 2014 Elsevier B.V. All rights reserved.
Spectral properties of Dy3+ doped ZnAl2O4 phosphor
NASA Astrophysics Data System (ADS)
Prakash, Ram; Kumar, Sandeep; Mahajan, Rubby; Khajuria, Pooja; Kumar, Vinay; Choudhary, R. J.; Phase, D. M.
2018-05-01
Herein, Dy3+ doped ZnAl2O4 phosphor was synthesized by the solution combustion method. The synthesized phosphor was characterized by X-ray diffraction (XRD), photoluminescence (PL) spectroscopy, UV-Vis spectroscopy and X-ray photoelectron spectroscopy (XPS). The phase purity of the phosphor was confirmed by the XRD studies that showed cubic symmetry of the synthesized phosphor. Under UV excitation (388 nm) the PL emission spectrum of the phosphor shows characteristic transition from the Dy3+ ion. A band gap of 5.2 eV was estimated from the diffused reflectance spectroscopy. The surface properties of the phosphor were studied using the X-ray photoelectron spectroscopy.
NASA Astrophysics Data System (ADS)
Chernyshev, I. V.; Golubev, V. N.; Chugaev, A. V.
2017-11-01
The enrichment of lead isotopic composition of nonuranium minerals, in the first place galena in 206Pb and 207Pb, as compared to common lead is a remarkable feature of uranium deposits. The study of such lead isotopic composition anomalous in 206Pb and 207Pb in uranium minerals provides an opportunity for not only identification of superimposed processes resulting in transformation of uranium ores during deposit history but also calculation of age of these processes under certain model assumptions. Galena from the Chauli deposit in the Chatkal-Qurama district, Uzbekistan, a typical representative of hydrothermal uranium deposits associated with domains of Phanerozoic continental volcanism, has been examined with the highprecision (±0.02%) MC-ICP-MS method. Twenty microsamples of galena were taken from polished sections. Six of them are galena hosted in carbonate adjacent to pitchblende spherulites or filling thin veinlets (approximately 60 μm) cutting pitchblende. Isotopically anomalous lead with 206Pb/204Pb and 207Pb/204Pb values reaching 20.462 and 15.743, respectively, has been found in these six microsamples in contrast to another fourteen in which the Pb-Pb characteristics are consistent with common lead. On the basis of these data and with account for the 292 ± 2 Ma age for the Chauli deposit, the age of epigenetic transformation of uranium ores of this deposit has been estimated. During this process, radiogenic lead partly lost from pitchblende was captured into galena. The obtained date is 170 Ma. In the Chatkal-Qurama district, these epigenetic processes are apparently caused by the interaction of uranium minerals with activated underground water under tectonic activity and relief transformation, which took place from the post-Permian (i.e., after the Chauli formation) to the Jurassic period.
Mohammed, Baba S; Engelhardt, Thomas; Cameron, Gary A; Hawwa, Ahmed F; Helms, Peter J; McLay, James S
2013-10-01
Ketorolac, a potent nonsteroidal anti-inflammatory drug used for pain control in children, exists as a racemate of inactive R (+) and active S (-) enantiomers. To develop a microsampling assay for the enantioselective analysis of ketorolac in children. Ketorolac enantiomers were extracted from 50 μl of plasma by liquid–liquid extraction and separated on a ChiralPak AD-RH. Detection was by a TSQ quantum triple quadrupole mass spectrometer with an electrospray ionisation source operating in a positive ion mode. Five children (age 13.8 (1.6) years, weight 52.7 (7.2) kg), were administered intravenous ketorolac 0.5mg/kg (maximum 10mg) and blood samples were taken at 0, 0.25, 0.5, 1, 2, 4, 6, 8 and 12 h post administration. CL, VD and t1/2 were calculated based on non-compartmental methods. The standard curves for R (+) and S (-) ketorolac were linear in the range 0–2000 ng/ml. The LLOQs of the method were 0.15 ng on column and 0.31 ng on column for R (+) and S (-) ketorolac, respectively. The median (range) VD and CL of R (+) and S (-) ketorolac were 0.12 l/kg (0.07–0.17), 0.017 l/h/kg (0.12–0.29) and 0.17 (0.09–0.31) l/kg, 0.049 (0.02–0.1) l/h/kg, p = 0.043), respectively. The median (range) elimination half-life (t1/2) of the R (+) and S (-) ketorolac was 5.0 h (2.5–5.8) and 3.1 h (1.8–4.4), p = 0.043), respectively. The development of a simple, rapid and reliable ketorolac assay suitable for paediatric PK studies is reported. Copyright © 2013 John Wiley & Sons, Ltd.
NIR detection of pits and pit fragments in fresh cherries (abstract)
USDA-ARS?s Scientific Manuscript database
The feasibility of using near infrared (NIR) diffuse reflectance spectroscopy for the detection of pits and pit fragments in cherries was demonstrated. For detection of whole pits, 300 cherries were obtained locally and pits were removed from half. NIR reflectance spectra were obtained in triplicate...
Evaluating leaf and canopy reflectance of stressed rice plants to monitor arsenic contamination
USDA-ARS?s Scientific Manuscript database
Arsenic contamination is a serious problem in rice cultivated soils of many developing countries. Hence, it is critical to monitor and control arsenic uptake in rice plants to avoid adverse effects on human health. This study evaluated the feasibility of using reflectance spectroscopy to monitor ars...
Nondestructive NIR reflectance spectroscopic method for rapid fatty acid analysis of peanut seeds
USDA-ARS?s Scientific Manuscript database
NIR reflectance spectroscopy was used to analyze the fatty acid concentration present in breeder's peanut seeds samples, rapidly and nondestructively. Absorbance spectra were collected in the wavelength range from 400 nm to 2500 nm using a NIR spectrometer. Fatty acids, oleic, linoleic and palmitic ...
Online high-speed NIR diffuse-reflectance imaging spectroscopy in food quality monitoring
NASA Astrophysics Data System (ADS)
Driver, Richard D.; Didona, Kevin
2009-05-01
The use of hyperspectral technology in the NIR for food quality monitoring is discussed. An example of the use of hyperspectral diffuse reflectance scanning and post-processing with a chemometric model shows discrimination between four pharmaceutical samples comprising Aspirin, Acetaminophen, Vitamin C and Vitamin D.
Cotrozzi, Lorenzo; Townsend, Philip A; Pellegrini, Elisa; Nali, Cristina; Couture, John J
2018-03-01
The Mediterranean basin can be considered a hot spot not only in terms of climate change (CC) but also for air quality. Assessing the impact of CC and air pollution on ecosystem functions is a challenging task, and adequate monitoring techniques are needed. This paper summarizes the present knowledge on the use of reflectance spectroscopy for the evaluation of the effects of air pollution on plants. First, the history of this technique is outlined. Next, we describe the vegetation reflectance spectrum, how it can be scaled from leaf to landscape levels, what information it contains, and how it can be exploited to understand plant and ecosystem functions. Finally, we review the literature concerning this topic, with special attention to Mediterranean air pollutants, showing the increasing interest in this technique. The ability of spectroscopy to detect the influence of air pollution on plant function of all major and minor Mediterranean pollutants has been evaluated, and ozone and its interaction with other gases (carbon dioxide, nitrogen oxides, and sulfur dioxide) have been the most studied. In the recent years, novel air pollutants, such as particulate matter, nitrogen deposition, and heavy metals, have drawn attention. Although various vegetation types have been studied, few of these species are representative of the Mediterranean environment. Thus, major emphasis should be placed on using vegetation spectroscopy for better understanding and monitoring the impact of air pollution on Mediterranean plants in the CC era.
Chen, Yu-Wen; Chen, Chien-Chih; Huang, Po-Jung; Tseng, Sheng-Hao
2016-01-01
Diffuse reflectance spectroscopy (DRS) based on the frequency-domain (FD) technique has been employed to investigate the optical properties of deep tissues such as breast and brain using source to detector separation up to 40 mm. Due to the modeling and system limitations, efficient and precise determination of turbid sample optical properties from the FD diffuse reflectance acquired at a source-detector separation (SDS) of around 1 mm has not been demonstrated. In this study, we revealed that at SDS of 1 mm, acquiring FD diffuse reflectance at multiple frequencies is necessary for alleviating the influence of inevitable measurement uncertainty on the optical property recovery accuracy. Furthermore, we developed artificial neural networks (ANNs) trained by Monte Carlo simulation generated databases that were capable of efficiently determining FD reflectance at multiple frequencies. The ANNs could work in conjunction with a least-square optimization algorithm to rapidly (within 1 second), accurately (within 10%) quantify the sample optical properties from FD reflectance measured at SDS of 1 mm. In addition, we demonstrated that incorporating the steady-state apparatus into the FD DRS system with 1 mm SDS would enable obtaining broadband absorption and reduced scattering spectra of turbid samples in the wavelength range from 650 to 1000 nm. PMID:27446671
A compact high-resolution 3-D imaging spectrometer for discovering Oases on Mars
Ge, J.; Ren, D.; Lunine, J.I.; Brown, R.H.; Yelle, R.V.; Soderblom, L.A.; ,
2002-01-01
A new design for a very lightweight, very high throughput reflectance sectrometer enabled by two new technologies being developed is presented. These new technologies include integral field unit optics to enable simultaneous imaging and spectroscopy at high spatial resolution with an infrared (IR) array, and silicon grisms to enable compact and high-resolution spectroscopy.
Playing with Light: Adventures in Optics and Spectroscopy for Honors and Majors General Chemistry
ERIC Educational Resources Information Center
van Staveren, Marie N.; Edwards, Kimberly D.; Apkarian, V. A.
2012-01-01
A lab was developed for use in an undergraduate honors and majors general chemistry laboratory to introduce students to optics, spectroscopy, and the underlying principles of quantum mechanics. This lab includes four mini-experiments exploring total internal reflection, the tunneling of light, spectra of sparklers and colored candles, and emission…
USDA-ARS?s Scientific Manuscript database
Skin is a relatively stable storage medium for carotenoids; non-invasive optical measurements of carotenoids in this tissue via Resonance Raman spectroscopy (RRS) serve as a non-invasive biomarker for fruit and vegetable (F/V) intake. The RRS method has been validated with HPLC-based measurements of...
Spectroscopy and reactivity of mineral analogs of the Martian soil
NASA Technical Reports Server (NTRS)
Banin, A.; Orenberg, J.; Roush, T.
1991-01-01
To answer the question of why life occurred on Earth but not on Mars requires a study of the geochemical and physical aspects of the Martian soil. Some of the best Mars analog mineral models of the soil have been prepared and justified according to known constraints of chemical composition, reflectance spectroscopy, and chemical reactivity. Detailed laboratory reflectance spectra in the ultraviolet, visible, and near infrared (.30 to 2.5 microns) and the infrared (2.5 to 25 microns) regions have been obtained for the pure candidate minerals and some analog mixtures and compared to Mars reflectance spectra. Modeling of the reflectance spectra from optical constraints determined for the analog minerals has begun and will be interpreted in terms of the effects of particle size variation, component mixing, and soil packing upon remotely sensed reflectance spectra. This has implications not only for Mars, but for other planets and planetoids. The ratio of Fe(II)/Fe(III) in the Martian soil analog materials on spectral reflectance in the visible range has begun, and the results will be evaluated according to conformity with the visible Mars reflectance spectrum. Some initial LR and GEX data have been collected for the mineral samples and their mixtures, which can be compared with the Viking data and interpreted in terms of the redox (Fe(II)/Fe(III) environment.
NASA Astrophysics Data System (ADS)
Mousavi, Monirehalsadat; Xie, Haiyan; Xie, Zhiyuan; Brydegaard, Mikkel; Axelsson, Johan; Andersson-Engels, Stefan
2013-11-01
Total resection of glioblastoma multiform (GBM), the most common and aggressive malignant brain tumor, is challenging among other things due to difficulty in intraoperative discrimination between normal and residual tumor cells. This project demonstrates the potential of a system based on a combination of autofluorescence and diffuse reflectance spectroscopy to be useful as an intraoperative guiding tool. In this context, a system based on 5 LEDs coupled to optical fibers was employed to deliver UV/visible light to the sample sequentially. Remitted light from the tissue; including diffuse reflected and fluorescence of endogenous and exogenous fluorophores, as well as its photobleaching product, is transmitted to one photodiode and four avalanche photodiodes. This instrument has been evaluated with very promising results by performing various tissue-equivalent phantom laboratory and clinical studies on skin lesions.
An automatic detection software for differential reflection spectroscopy
NASA Astrophysics Data System (ADS)
Yuksel, Seniha Esen; Dubroca, Thierry; Hummel, Rolf E.; Gader, Paul D.
2012-06-01
Recent terrorist attacks have sprung a need for a large scale explosive detector. Our group has developed differential reflection spectroscopy which can detect explosive residue on surfaces such as parcel, cargo and luggage. In short, broad band ultra-violet and visible light is shone onto a material (such as a parcel) moving on a conveyor belt. Upon reflection off the surface, the light intensity is recorded with a spectrograph (spectrometer in combination with a CCD camera). This reflected light intensity is then subtracted and normalized with the next data point collected, resulting in differential reflection spectra in the 200-500 nm range. Explosives show spectral finger-prints at specific wavelengths, for example, the spectrum of 2,4,6, trinitrotoluene (TNT) shows an absorption edge at 420 nm. Additionally, we have developed an automated software which detects the characteristic features of explosives. One of the biggest challenges for the algorithm is to reach a practical limit of detection. In this study, we introduce our automatic detection software which is a combination of principal component analysis and support vector machines. Finally we present the sensitivity and selectivity response of our algorithm as a function of the amount of explosive detected on a given surface.
Deng, Xuegong; Braun, Gary B; Liu, Sheng; Sciortino, Paul F; Koefer, Bob; Tombler, Thomas; Moskovits, Martin
2010-05-12
The surface-enhanced Raman spectroscopy (SERS) activity and the optical reflectance of a subwavelength gold nanograting fabricated entirely using top down technologies on silicon wafers are presented. The grating consists of 120 nm gold cladding on top of parallel silica nanowires constituting the grating's lines, with gaps between nanowires <10 nm wide at their narrowest point. The grating produces inordinately intense SERS and shows very strong polarization dependence. Reflectance measurements for the optimized grating indicate that (when p-polarization is used and at least one of the incident electric field components lies across the grating lines) the reflectance drops to <1% at resonance, indicating that essentially all of the radiant energy falling on the surface is coupled into the grating. The SERS intensity and the reflectance at resonance anticorrelate predicatively, suggesting that reflectance measurements can provide a nondestructive, wafer-level test of SERS efficacy. The SERS performance of the gratings is very uniform and reproducible. Extensive measurements on samples cut from both the same wafer and from different wafers, produce a SERS intensity distribution function that is similar to that obtained for ordinary Raman measurements carried out at multiple locations on a polished (100) silicon wafer.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bobbitt, Jonathan M; Weibel, Stephen C; Elshobaki, Moneim
2014-12-16
Fourier transform (FT)-plasmon waveguide resonance (PWR) spectroscopy measures light reflectivity at a waveguide interface as the incident frequency and angle are scanned. Under conditions of total internal reflection, the reflected light intensity is attenuated when the incident frequency and angle satisfy conditions for exciting surface plasmon modes in the metal as well as guided modes within the waveguide. Expanding upon the concept of two-frequency surface plasmon resonance developed by Peterlinz and Georgiadis [ Opt. Commun. 1996, 130, 260], the apparent index of refraction and the thickness of a waveguide can be measured precisely and simultaneously by FT-PWR with an averagemore » percent relative error of 0.4%. Measuring reflectivity for a range of frequencies extends the analysis to a wide variety of sample compositions and thicknesses since frequencies with the maximum attenuation can be selected to optimize the analysis. Additionally, the ability to measure reflectivity curves with both p- and s-polarized light provides anisotropic indices of refraction. FT-PWR is demonstrated using polystyrene waveguides of varying thickness, and the validity of FT-PWR measurements are verified by comparing the results to data from profilometry and atomic force microscopy (AFM).« less
Bobbitt, Jonathan M; Weibel, Stephen C; Elshobaki, Moneim; Chaudhary, Sumit; Smith, Emily A
2014-12-16
Fourier transform (FT)-plasmon waveguide resonance (PWR) spectroscopy measures light reflectivity at a waveguide interface as the incident frequency and angle are scanned. Under conditions of total internal reflection, the reflected light intensity is attenuated when the incident frequency and angle satisfy conditions for exciting surface plasmon modes in the metal as well as guided modes within the waveguide. Expanding upon the concept of two-frequency surface plasmon resonance developed by Peterlinz and Georgiadis [Opt. Commun. 1996, 130, 260], the apparent index of refraction and the thickness of a waveguide can be measured precisely and simultaneously by FT-PWR with an average percent relative error of 0.4%. Measuring reflectivity for a range of frequencies extends the analysis to a wide variety of sample compositions and thicknesses since frequencies with the maximum attenuation can be selected to optimize the analysis. Additionally, the ability to measure reflectivity curves with both p- and s-polarized light provides anisotropic indices of refraction. FT-PWR is demonstrated using polystyrene waveguides of varying thickness, and the validity of FT-PWR measurements are verified by comparing the results to data from profilometry and atomic force microscopy (AFM).
NASA Astrophysics Data System (ADS)
da Silva, Aline Santana; Fernandes, Flávio Cesar Bedatty; Tognolli, João Olímpio; Pezza, Leonardo; Pezza, Helena Redigolo
2011-09-01
This article describes a simple, inexpensive, and environmentally friendly method for the monitoring of glyphosate using diffuse reflectance spectroscopy. The proposed method is based on reflectance measurements of the colored compound produced from the spot test reaction between glyphosate and p-dimethylaminocinnamaldehyde ( p-DAC) in acid medium, using a filter paper as solid support. Experimental designs were used to optimize the analytical conditions. All reflectance measurements were carried out at 495 nm. Under optimal conditions, the glyphosate calibration graphs obtained by plotting the optical density of the reflectance signal (A R) against the concentration were linear in the range 50-500 μg mL -1, with a correlation coefficient of 0.9987. The limit of detection (LOD) for glyphosate was 7.28 μg mL -1. The technique was successfully applied to the direct determination of glyphosate in commercial formulations, as well as in water samples (river water, pure water and mineral drinking water) after a previous clean-up or pre-concentration step. Recoveries were in the ranges 93.2-102.6% and 91.3-102.9% for the commercial formulations and water samples, respectively.
NASA Astrophysics Data System (ADS)
Du Le, Vinh Nguyen; Provias, John; Murty, Naresh; Patterson, Michael S.; Nie, Zhaojun; Hayward, Joseph E.; Farrell, Thomas J.; McMillan, William; Zhang, Wenbin; Fang, Qiyin
2017-02-01
Glioma itself accounts for 80% of all malignant primary brain tumors, and glioblastoma multiforme (GBM) accounts for 55% of such tumors. Diffuse reflectance and fluorescence spectroscopy have the potential to discriminate healthy tissues from abnormal tissues and therefore are promising noninvasive methods for improving the accuracy of brain tissue resection. Optical properties were retrieved using an experimentally evaluated inverse solution. On average, the scattering coefficient is 2.4 times higher in GBM than in low grade glioma (LGG), and the absorption coefficient is 48% higher. In addition, the ratio of fluorescence to diffuse reflectance at the emission peak of 460 nm is 2.6 times higher for LGG while reflectance at 650 nm is 2.7 times higher for GBM. The results reported also show that the combination of diffuse reflectance and fluorescence spectroscopy could achieve sensitivity of 100% and specificity of 90% in discriminating GBM from LGG during ex vivo measurements of 22 sites from seven glioma specimens. Therefore, the current technique might be a promising tool for aiding neurosurgeons in determining the extent of surgical resection of glioma and, thus, improving intraoperative tumor identification for guiding surgical intervention.
da Silva, Aline Santana; Fernandes, Flávio Cesar Bedatty; Tognolli, João Olímpio; Pezza, Leonardo; Pezza, Helena Redigolo
2011-09-01
This article describes a simple, inexpensive, and environmentally friendly method for the monitoring of glyphosate using diffuse reflectance spectroscopy. The proposed method is based on reflectance measurements of the colored compound produced from the spot test reaction between glyphosate and p-dimethylaminocinnamaldehyde (p-DAC) in acid medium, using a filter paper as solid support. Experimental designs were used to optimize the analytical conditions. All reflectance measurements were carried out at 495 nm. Under optimal conditions, the glyphosate calibration graphs obtained by plotting the optical density of the reflectance signal (AR) against the concentration were linear in the range 50-500 μg mL(-1), with a correlation coefficient of 0.9987. The limit of detection (LOD) for glyphosate was 7.28 μg mL(-1). The technique was successfully applied to the direct determination of glyphosate in commercial formulations, as well as in water samples (river water, pure water and mineral drinking water) after a previous clean-up or pre-concentration step. Recoveries were in the ranges 93.2-102.6% and 91.3-102.9% for the commercial formulations and water samples, respectively. Copyright © 2011 Elsevier B.V. All rights reserved.
Du Le, Vinh Nguyen; Provias, John; Murty, Naresh; Patterson, Michael S; Nie, Zhaojun; Hayward, Joseph E; Farrell, Thomas J; McMillan, William; Zhang, Wenbin; Fang, Qiyin
2017-02-01
Glioma itself accounts for 80% of all malignant primary brain tumors, and glioblastoma multiforme (GBM) accounts for 55% of such tumors. Diffuse reflectance and fluorescence spectroscopy have the potential to discriminate healthy tissues from abnormal tissues and therefore are promising noninvasive methods for improving the accuracy of brain tissue resection. Optical properties were retrieved using an experimentally evaluated inverse solution. On average, the scattering coefficient is 2.4 times higher in GBM than in low grade glioma (LGG), and the absorption coefficient is 48% higher. In addition, the ratio of fluorescence to diffuse reflectance at the emission peak of 460 nm is 2.6 times higher for LGG while reflectance at 650 nm is 2.7 times higher for GBM. The results reported also show that the combination of diffuse reflectance and fluorescence spectroscopy could achieve sensitivity of 100% and specificity of 90% in discriminating GBM from LGG during ex vivo measurements of 22 sites from seven glioma specimens. Therefore, the current technique might be a promising tool for aiding neurosurgeons in determining the extent of surgical resection of glioma and, thus, improving intraoperative tumor identification for guiding surgical intervention.
Vishwanath, Karthik; Chang, Kevin; Klein, Daniel; Deng, Yu Feng; Chang, Vivide; Phelps, Janelle E; Ramanujam, Nimmi
2011-02-01
Steady-state diffuse reflection spectroscopy is a well-studied optical technique that can provide a noninvasive and quantitative method for characterizing the absorption and scattering properties of biological tissues. Here, we compare three fiber-based diffuse reflection spectroscopy systems that were assembled to create a light-weight, portable, and robust optical spectrometer that could be easily translated for repeated and reliable use in mobile settings. The three systems were built using a broadband light source and a compact, commercially available spectrograph. We tested two different light sources and two spectrographs (manufactured by two different vendors). The assembled systems were characterized by their signal-to-noise ratios, the source-intensity drifts, and detector linearity. We quantified the performance of these instruments in extracting optical properties from diffuse reflectance spectra in tissue-mimicking liquid phantoms with well-controlled optical absorption and scattering coefficients. We show that all assembled systems were able to extract the optical absorption and scattering properties with errors less than 10%, while providing greater than ten-fold decrease in footprint and cost (relative to a previously well-characterized and widely used commercial system). Finally, we demonstrate the use of these small systems to measure optical biomarkers in vivo in a small-animal model cancer therapy study. We show that optical measurements from the simple portable system provide estimates of tumor oxygen saturation similar to those detected using the commercial system in murine tumor models of head and neck cancer.
Yun, Dong-Jin; Shin, Weon-Ho; Bulliard, Xavier; Park, Jong Hwan; Kim, Seyun; Chung, Jae Gwan; Kim, Yongsu; Heo, Sung; Kim, Seong Heon
2016-08-26
A novel, direct method for the characterization of the energy level alignments at bulk-heterojunction (BHJ)/electrode interfaces on the basis of electronic spectroscopy measurements is proposed. The home-made in situ photoemission system is used to perform x-ray/ultraviolet photoemission spectroscopy (XPS/UPS), reflection electron energy loss spectroscopy (REELS) and inverse photoemission spectroscopy of organic-semiconductors (OSCs) deposited onto a Au substrate. Through this analysis system, we are able to obtain the electronic structures of a boron subphthalocyanine chloride:fullerene (SubPC:C60) BHJ and those of the separate OSC/electrode structures (SubPC/Au and C60/Au). Morphology and chemical composition analyses confirm that the original SubPC and C60 electronic structures remain unchanged in the electrodes prepared. Using this technique, we ascertain that the position and area of the nearest peak to the Fermi energy (EF = 0 eV) in the UPS (REELS) spectra of SubPC:C60 BHJ provide information on the highest occupied molecular orbital level (optical band gap) and combination ratio of the materials, respectively. Thus, extracting the adjusted spectrum from the corresponding SubPC:C60 BHJ UPS (REELS) spectrum reveals its electronic structure, equivalent to that of the C60 materials. This novel analytical approach allows complete energy-level determination for each combination ratio by separating its electronic structure information from the BHJ spectrum.
Mohamad Asri, Muhammad Naeim; Mat Desa, Wan Nur Syuhaila; Ismail, Dzulkiflee
2018-01-01
The potential combination of two nondestructive techniques, that is, Raman spectroscopy (RS) and attenuated total reflectance-fourier transform infrared (ATR-FTIR) spectroscopy with Pearson's product moment correlation (PPMC) coefficient (r) and principal component analysis (PCA) to determine the actual source of red gel pen ink used to write a simulated threatening note, was examined. Eighteen (18) red gel pens purchased from Japan and Malaysia from November to December 2014 where one of the pens was used to write a simulated threatening note were analyzed using RS and ATR-FTIR spectroscopy, respectively. The spectra of all the red gel pen inks including the ink deposited on the simulated threatening note gathered from the RS and ATR-FTIR analyses were subjected to PPMC coefficient (r) calculation and principal component analysis (PCA). The coefficients r = 0.9985 and r = 0.9912 for pairwise combination of RS and ATR-FTIR spectra respectively and similarities in terms of PC1 and PC2 scores of one of the inks to the ink deposited on the simulated threatening note substantiated the feasibility of combining RS and ATR-FTIR spectroscopy with PPMC coefficient (r) and PCA for successful source determination of red gel pen inks. The development of pigment spectral library had allowed the ink deposited on the threatening note to be identified as XSL Poppy Red (CI Pigment Red 112). © 2017 American Academy of Forensic Sciences.
Tallo-Parra, Oriol; Albanell, Elena; Carbajal, Annais; Monclús, Laura; Manteca, Xavier; Lopez-Bejar, Manel
2017-08-01
Concentrations of different steroid hormones have been used in cows as a measure of adrenal or gonadal activity and, thus, as indicators of stress or reproductive state. Detecting cortisol and progesterone in cow hair provides a long-term integrative value of retrospective adrenal or gonadal/placental activity, respectively. Current techniques for steroid detection require a hormone-extraction procedure that involves time, several types of equipment, management of reagents, and some assay procedures (which can also be time-consuming and can destroy the samples). In contrast, near-infrared reflectance spectroscopy (NIRS) is a multi-component predictor technique, characterized as rapid, nondestructive for the sample, and reagent-free. However, as a predictor technique, NIRS needs to be calibrated and validated for each matrix, hormone, and species. The main objective of this study was to evaluate the predictive value of the NIRS technique for hair cortisol and progesterone quantification in cows by using specific enzyme immunoassay as a reference method. Hair samples from 52 adult Friesian lactating cows from a commercial dairy farm were used. Reflectance spectra of hair samples were determined with a NIR reflectance spectrophotometer before and after trimming them. Although similar results were obtained, a slightly better relationship between the reference data and NIRS predicted values was found using trimmed samples. Near infrared reflectance spectroscopy demonstrated its ability to predict cortisol and progesterone concentrations with certain accuracy (R 2 = 0.90 for cortisol and R 2 = 0.87 for progesterone). Although NIRS is far from being a complete alternative to current methodologies, the proposed equations can offer screening capability. Considering the advantages of both fields, our results open the possibility for future work on the combination of hair steroid measurement and NIRS methodology.
Kaale, Eliangiringa; Hope, Samuel M; Jenkins, David; Layloff, Thomas
2016-01-01
To assess the quality of cotrimoxazole tablets produced by a Tanzanian manufacturer by a newly instituted quality assurance programme. Tablets underwent a diffuse reflectance spectroscopy procedure with periodic quality assessment confirmation by assay and dissolution testing using validated HPTLC techniques (including weight variation and disintegration evaluations). Based on results from the primary test methods, the first group of product was <80% compliant, whereas subsequent groups reached >99% compliance. This approach provides a model for rapidly assuring product quality of future procurements of other products that is more cost-effective than traditional pharmaceutical testing techniques. © 2015 John Wiley & Sons Ltd.
Structural and optical investigation on the wings of Idea malabarica (Moore, 1877).
Sackey, Juliet; Nuru, Zebib Y; Sone, Bertrand Tumbain; Maaza, Malik
2017-02-01
The nanostructures on the wings of Idea malabarica (Moore, 1877) were analysed using scanning electron microscopy, energy dispersive X-ray spectroscopy, atomic force microscopy, Fourier transform-infrared spectroscopy, and reflectance measurements. The chemical and morphological analyses revealed the chitin-based intricate nanostructures. The influence of the nanostructures on the wetting characteristics of the wing was investigated using optical imaging. Applying the Maxwell-Garnet approximation to the porosities within the nanostructures, the refractive indices, which relate the reflectance response, were estimated. It was concluded that the colour seen on the wings of the Idea malabarica originate from the nanostructural configurations of the chitin-based structures and the embedded pigment.
NASA Astrophysics Data System (ADS)
Pakela, Julia M.; Lee, Seung Yup; Hedrick, Taylor L.; Vishwanath, Karthik; Helton, Michael C.; Chung, Yooree G.; Kolodziejski, Noah J.; Staples, Christopher J.; McAdams, Daniel R.; Fernandez, Daniel E.; Christian, James F.; O'Reilly, Jameson; Farkas, Dana; Ward, Brent B.; Feinberg, Stephen E.; Mycek, Mary-Ann
2017-02-01
In reconstructive surgery, impeded blood flow in microvascular free flaps due to a compromise in arterial or venous patency secondary to blood clots or vessel spasms can rapidly result in flap failures. Thus, the ability to detect changes in microvascular free flaps is critical. In this paper, we report progress on in vivo pre-clinical testing of a compact, multimodal, fiber-based diffuse correlation and reflectance spectroscopy system designed to quantitatively monitor tissue perfusion in a porcine model's surgically-grafted free flap. We also describe the device's sensitivity to incremental blood flow changes and discuss the prospects for continuous perfusion monitoring in future clinical translational studies.
Amorphous silicon carbide coatings for extreme ultraviolet optics
NASA Technical Reports Server (NTRS)
Kortright, J. B.; Windt, David L.
1988-01-01
Amorphous silicon carbide films formed by sputtering techniques are shown to have high reflectance in the extreme ultraviolet spectral region. X-ray scattering verifies that the atomic arrangements in these films are amorphous, while Auger electron spectroscopy and Rutherford backscattering spectroscopy show that the films have composition close to stoichiometric SiC, although slightly C-rich, with low impurity levels. Reflectance vs incidence angle measurements from 24 to 1216 A were used to derive optical constants of this material, which are presented here. Additionally, the measured extreme ultraviolet efficiency of a diffraction grating overcoated with sputtered amorphous silicon carbide is presented, demonstrating the feasibility of using these films as coatings for EUV optics.
Analysis of remote reflectin spectroscopy to monitor plant health
NASA Technical Reports Server (NTRS)
Woodhouse, R.; Heeb, M.; Berry, W.; Hoshizaki, T.; Wood, M.
1994-01-01
Remote non-contact reflection spectroscopy is examined as a method for detecting stress in Controlled Ecological Life Support System (CELSS) type crops. Lettuce (Latuca Sativa L. cv. Waldmans Green) and wheat (Triticum Aestivum L. cv. Yecora Rojo) were grown hydroponically. Copper and zinc treatments provided toxic conditions. Nitrogen, phosphorous, and potassium treatments were used for deficiency conditions. Water stress was also induced in test plants. Reflectance spectra were obtained in the visible and near infrared (400nm to 2600nm) wavebands. Numerous effects of stress conditions can be observed in the collected spectra and this technique appears to have promise as a remote monitor of plant health, but significant research remains to be conducted to realize the promise.
Niece, Krista L.
2015-01-01
Colistin use has increased in response to the advent of infections caused by multidrug-resistant organisms. It is administered parenterally as an inactive prodrug, colistin methanesulfonate (CMS). Various formulations of CMS and labeling conventions can lead to confusion about colistin dosing, and questions remain about the pharmacokinetics of CMS. Since CMS does not have strong UV absorbance, current methods employ a laborious process of chemical conversion to colistin followed by precolumn derivatization to detect formed colistin by high-performance liquid chromatography. Here, we report a method for direct quantification of colistin methanesulfonate by attenuated total reflectance Fourier transform infrared spectroscopy (ATR FTIR). PMID:26124160
Solubility of the sesquiterpene alcohol patchoulol in supercritical carbon dioxide
Hybertson, Brooks M.
2009-01-01
The solubility of the sesquiterpene alcohol patchoulol in supercritical carbon dioxide was measured at P ranging from 10.0 MPa to 25.0 MPa and T of 40.0 and 50.0 °C using a simple microsampling type apparatus with a 100.5 µL sample loop to remove aliquots for off-line analysis. The system was first validated using vanillin with off-line spectrophotometric analysis, then utilized for patchoulol measurements with off-line GC-MS analysis. The measured solubility of patchoulol in supercritical CO2 ranged from mole fractions of 0.43 × 10−3 at 10.0 MPa and 50.0 °C to 9.45 × 10−3 at 25.0 MPa and 40.0 °C. PMID:19424449
DBS-LC-MS/MS assay for caffeine: validation and neonatal application.
Bruschettini, Matteo; Barco, Sebastiano; Romantsik, Olga; Risso, Francesco; Gennai, Iulian; Chinea, Benito; Ramenghi, Luca A; Tripodi, Gino; Cangemi, Giuliana
2016-09-01
DBS might be an appropriate microsampling technique for therapeutic drug monitoring of caffeine in infants. Nevertheless, its application presents several issues that still limit its use. This paper describes a validated DBS-LC-MS/MS method for caffeine. The results of the method validation showed an hematocrit dependence. In the analysis of 96 paired plasma and DBS clinical samples, caffeine levels measured in DBS were statistically significantly lower than in plasma but the observed differences were independent from hematocrit. These results clearly showed the need for extensive validation with real-life samples for DBS-based methods. DBS-LC-MS/MS can be considered to be a good alternative to traditional methods for therapeutic drug monitoring or PK studies in preterm infants.
NASA Astrophysics Data System (ADS)
Fisher, E. A.
2015-12-01
The reactivation of Montserrat's South Soufrière-Soufrière Hills volcanic complex has impelled the creation of tephrochronologic records in the Lesser Antilles Arc in order to assess volcanic hazards to human safety. Developing an eruptive history of Montserrat by recording tephra layers preserved in marine sediment is hindered by the lack of a rapid, non-destructive method for detecting cryptotephra, tephra deposits invisible to the naked eye, in marine cores. Identifying cryptotephra is important because some cryptotephra layers represent primary tephra emplacement from small proximal eruptions, events that if excluded from a volcanic record could mischaracterize a volcano's eruptive frequency over time. VSWIR [0.4-2.5 μm] reflectance spectroscopy is a candidate for rapid, non-destructive cryptotephra detection in marine sediment cores because it can detect tephra in hemipelagic sediment using summary parameters sensitive to iron content and clay minerals (McCanta et al. 2014, AGU abstract OS53D-1086). Spectra from marine cores U1396C-1H-1A through U1396C-1H-5A, collected during International Ocean Discovery Program (IODP) mission 340, reveal 29 potential cryptotephra layers (McCanta et al. 2014, AGU abstract OS53D-1086). This study seeks to determine the effectiveness of reflectance spectroscopy at identifying cryptotephra by measuring the abundance of volcanic materials (i.e., glass shards/vesicular pumice and non-vesicular lava clasts) in these layers ( LeFriant et al. 2008; Cassidy et al. 2014). Component analysis was conducted on select core intervals with both cryptotephra-identifying peaks in reflectance parameters, and tephra-indicative peaks in core scanning XRF and magnetic susceptibility parameters (McCanta et al. 2014, AGU abstract OS53D-1086). Samples in this subset show abundances of non-vesicular lava and vesicular pumice clasts above expected background abundances, supporting the existence of cryptotephra at these locations (Fig. 1; LeFriant et al. 2008; Cassidy et al. 2014). This suggests that reflectance spectroscopy is an effective means of identifying cryptotephra in situ, and when employed in concert with other core scanning techniques could facilitate widespread rapid identification of cryptotephra in future tephrochronology studies.
Thermal removal from near-infrared imaging spectroscopy data of the Moon
Clark, R.N.; Pieters, C.M.; Green, R.O.; Boardman, J.W.; Petro, N.E.
2011-01-01
In the near-infrared from about 2 ??m to beyond 3 ??m, the light from the Moon is a combination of reflected sunlight and emitted thermal emission. There are multiple complexities in separating the two signals, including knowledge of the local solar incidence angle due to topography, phase angle dependencies, emissivity, and instrument calibration. Thermal emission adds to apparent reflectance, and because the emission's contribution increases over the reflected sunlight with increasing wavelength, absorption bands in the lunar reflectance spectra can be modified. In particular, the shape of the 2 ??m pyroxene band can be distorted by thermal emission, changing spectrally determined pyroxene composition and abundance. Because of the thermal emission contribution, water and hydroxyl absorptions are reduced in strength, lowering apparent abundances. It is important to quantify and remove the thermal emission for these reasons. We developed a method for deriving the temperature and emissivity from spectra of the lunar surface and removing the thermal emission in the near infrared. The method is fast enough that it can be applied to imaging spectroscopy data on the Moon. Copyright ?? 2011 by the American Geophysical Union.
Thermal removal from near-infrared imaging spectroscopy data of the Moon
Clark, Roger N.; Pieters, Carle M.; Green, Robert O.; Boardman, J.W.; Petro, Noah E.
2011-01-01
In the near-infrared from about 2 μm to beyond 3 μm, the light from the Moon is a combination of reflected sunlight and emitted thermal emission. There are multiple complexities in separating the two signals, including knowledge of the local solar incidence angle due to topography, phase angle dependencies, emissivity, and instrument calibration. Thermal emission adds to apparent reflectance, and because the emission's contribution increases over the reflected sunlight with increasing wavelength, absorption bands in the lunar reflectance spectra can be modified. In particular, the shape of the 2 μm pyroxene band can be distorted by thermal emission, changing spectrally determined pyroxene composition and abundance. Because of the thermal emission contribution, water and hydroxyl absorptions are reduced in strength, lowering apparent abundances. It is important to quantify and remove the thermal emission for these reasons. We developed a method for deriving the temperature and emissivity from spectra of the lunar surface and removing the thermal emission in the near infrared. The method is fast enough that it can be applied to imaging spectroscopy data on the Moon.
Mamani-Linares, L W; Gallo, C; Alomar, D
2012-02-01
Visible and near infrared reflectance spectroscopy (VIS-NIRS) was used to discriminate meat and meat juices from three livestock species. In a first trial, samples of Longissimus lumborum muscle, corresponding to beef (31) llamas (21) and horses (27), were homogenised and their spectra collected in reflectance (NIRSystems 6500 scanning monochromator, in the range of 400-2500 nm). In the second trial, samples of meat juice (same muscle) from the same species (20 beef, 19 llama and 19 horse) were scanned in folded transmission (transflectance). Discriminating models (PLS regression) were developed against "dummy" variables, testing different mathematical treatments of the spectra. Best models indentified the species of almost all samples by their meat (reflectance) or meat juice (transflectance) spectra. A few (three of beef and one of llama, for meat samples; one of beef and one of horse, for juice samples) were classified as uncertain. It is concluded that NIRS is an effective tool to recognise meat and meat juice from beef, llama and horses. Copyright © 2011 Elsevier Ltd. All rights reserved.
Gabrieli, Francesca; Dooley, Kathryn A; Zeibel, Jason G; Howe, James D; Delaney, John K
2018-06-18
Microscale mid-infrared (mid-IR) imaging spectroscopy is used for the mapping of chemical functional groups. The extension to macroscale imaging requires that either the mid-IR radiation reflected off or that emitted by the object be greater than the radiation from the thermal background. Reflectance spectra can be obtained using an active IR source to increase the amount of radiation reflected off the object, but rapid heating of greater than 4 °C can occur, which is a problem for paintings. Rather than using an active source, by placing a highly reflective tube between the painting and camera and introducing a low temperature source, thermal radiation from the room can be reduced, allowing the IR radiation emitted by the painting to dominate. Thus, emissivity spectra of the object can be recovered. Using this technique, mid-IR emissivity image cubes of paintings were collected at high collection rates with a low-noise, line-scanning imaging spectrometer, which allowed pigments and paint binders to be identified and mapped. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Pommerol, A.; Brissaud, O.; Schmitt, B.; Quirico, E.; Doute, S.
2007-08-01
We have developed an original experimental facility designed to measure the bidirectional reflectance spectra of planetary analog materials. These measurements are helpful to interpret the observations of the spectrometers on board space probes in orbit around various Solar System bodies. The central part of the facility is the LPG spectrogonio- radiometer (Brissaud et al., 2004). This instrument provides measurements of samples BRDF (Bidirectional Reflectance Distribution Function) with high photometric and spectrometric accuracy in the spectral range of visible and near-infrared (0.3 - 4.8 microns). Measurements can be made at any value of incidence and emergence angle up to 80°. Azimuth angle is allowed to vary between 0 and 180°. The instrument was recently installed in a cold room allowing ambient temperatures as low as -20°C. This makes possible the measurements on different kinds of water ice samples (slab ice, frost, snow...) and mixtures of minerals and water ice with unprecedented accuracy. We also have designed and built a simulation chamber to measure spectra of samples (water ice and/or minerals) under an atmosphere with perfectly controlled temperature, pressure and composition. The main objective of this last improvement is the study of water exchange between planetary regolith analogs and atmosphere (adsorption/ desorption, condensation/sublimation). Experimental results will mainly apply to Martian water cycle and hydrated mineralogy. This simulation chamber also provides an efficient way to obtain bidirectional reflectance spectra of dry materials (removal of adsorbed water) with implications for planetary bodies without atmospheric or surface water (Titan, asteroids...). The reflectance spectroscopy facility is part of a large panel of instruments and techniques available at Laboratoire de Planetologie de Grenoble that provide complementary measurements on the same samples: infrared transmission spectroscopy of thin ice films, thick liquid and solid samples and samples diluted in KBr pellets, infrared imaging microscope, numerical modeling of bidirectional reflectance spectra using laboratory-measured optical constants. We will present different examples of experimental results obtained on the reflectance spectroscopy facility: - Effects of particle size, mixtures between samples with different albedo and measurement geometries on the water-of-hydration near-infrared absorption signatures with implications for the Martian regolith water content. - BRDF of regolith analogs and natural snow. - Hydration and dehydration of planetary analogs. - Spectra of different kinds of mixtures between water ice and minerals. We will briefly discuss the planetary implications of each of these measurements and detail the future investigations that will be undertaken on our experimental facility.
P. David Jones; Laurence R. Schimleck; Gary F. Peter; Richard F. Daniels; Alexander Clark
2006-01-01
The use of calibrated near infrared (NIR) spectroscopy for predicting the chemical composition of Pirus taeda L. (loblolly pine) wood samples is investigated. Seventeen P. taeda radial strips, representing seven different sites were selected and NlR spectra were obtained from the radial longitudinal face of each strip. The spectra...
Mohamad Nabavi; Joseph Dahlen; Laurence Schimleck; Thomas L. Eberhardt; Cristian Montes
2018-01-01
This study developed regional calibration models for the prediction of loblolly pine (Pinus taeda) tracheid properties using near-infrared (NIR) spectroscopy. A total of 1842 pith-to-bark radial strips, aged 19â31 years, were acquired from 268 trees from 109 stands across the southeastern USA. Diffuse reflectance NIR spectra were collected at 10-mm...
Laser Infrared Desorption Spectroscopy to Detect Complex Organic Molecules on Icy Planetary Surfaces
NASA Technical Reports Server (NTRS)
Sollit, Luke S.; Beegle, Luther W.
2008-01-01
Laser Desorption-Infrared Spectroscopy (LD-IR) uses an IR laser pulse to desorb surface materials while a spectrometer measures the emission spectrum of the desorbed materials (Figure 1). In this example, laser desorption operates by having the incident laser energy absorbed by near surface material (10 microns in depth). This desorption produces a plume that exists in an excited state at elevated temperatures. A natural analog for this phenomenon can be observed when comets approach the sun and become active and individual molecular emission spectra can be observed in the IR [1,2,3,4,5]. When this occurs in comets, the same species that initially emit radiation down to the ground state are free to absorb it, reducing the amount of detectable emission features. The nature of our technique results in absorption not occurring, because the laser pulse could easily be moved away form the initial desorption plume, and still have better spatial resolution then reflectance spectroscopy. In reflectance spectroscopy, trace components have a relatively weak signal when compared to the entire active nature of the surface. With LDIR, the emission spectrum is used to identify and analyze surface materials.
The use of UV-visible reflectance spectroscopy as an objective tool to evaluate pearl quality.
Agatonovic-Kustrin, Snezana; Morton, David W
2012-07-01
Assessing the quality of pearls involves the use of various tools and methods, which are mainly visual and often quite subjective. Pearls are normally classified by origin and are then graded by luster, nacre thickness, surface quality, size, color and shape. The aim of this study was to investigate the capacity of Artificial Neural Networks (ANNs) to classify and estimate the quality of 27 different pearls from their UV-Visible spectra. Due to the opaque nature of pearls, spectroscopy measurements were performed using the Diffuse Reflectance UV-Visible spectroscopy technique. The spectra were acquired at two different locations on each pearl sample in order to assess surface homogeneity. The spectral data (inputs) were smoothed to reduce the noise, fed into ANNs and correlated to the pearl's quality/grading criteria (outputs). The developed ANNs were successful in predicting pearl type, mollusk growing species, possible luster and color enhancing, donor condition/type, recipient/host color, donor color, pearl luster, pearl color, origin. The results of this study shows that the developed UV-Vis spectroscopy-ANN method could be used as a more objective method of assessing pearl quality (grading) and may become a valuable tool for the pearl grading industry.
Synthesis and photocatalytic activity of ytterbium-doped titania/diatomite composite photocatalysts
NASA Astrophysics Data System (ADS)
Tang, Wenjian; Qiu, Kehui; Zhang, Peicong; Yuan, Xiqiang
2016-01-01
Ytterbium-doped titanium dioxide (Yb-TiO2)/diatomite composite materials with different Yb concentrations were prepared by sol-gel method. The phase structure, morphology, and chemical composition of the as-prepared composites were well characterized by X-ray diffraction (XRD), Fourier transform infrared spectroscopy, Raman spectroscopy, scanning electron microscopy (SEM), and ultraviolet-visible (UV-vis) diffuse reflection spectroscopy. The XRD and Raman spectroscopy analysis indicated that the TiO2 existed in the form of pure anatase in the composites. The SEM images exhibited the well deposition and dispersion of TiO2 nanoparticles with little agglomeration on the surfaces of diatoms. The UV-vis diffuse reflection spectra showed that the band gap of TiO2 could be narrowed by the introduction of Yb species, which was further affected by doping concentration of Yb. The photocatalytic activity of synthesized samples was investigated by the degradation of methylene blue (MB) under UV light irradiation. It was observed that the photocatalytic degradation followed a pseudo-first-order kinetics according to the Langmuir-Hinshelwood model. Compared to TiO2 and TiO2/diatomite, the Yb-TiO2/diatomite composites exhibited higher photocatalytic activity toward degradation of MB using UV light irradiation.
NASA Astrophysics Data System (ADS)
Chen, Jianbo; Wang, Yue; Liu, Aoxue; Rong, Lixin; Wang, Jingjuan
2018-03-01
Fritillariae Bulbus, the dried bulbs of several species of the genus Fritillaria, is often used in traditional Chinese medicine for the treatment of cough and pulmonary diseases. However, the similar appearances make it difficult to identify different kinds of Fritillariae Bulbus. In this research, Fourier transform near-infrared (FT-NIR) spectroscopy with a reflection fiber probe is employed for the direct testing and automatic identification of different kinds of Fritillariae Bulbus to ensure the authenticity, efficacy and safety. The bulbs can be measured directly without pulverizing. According to the two-dimensional (2D) correlation analysis and statistical analysis, the height ratio of the two peaks near 4860 cm-1 and 4750 cm-1 in the second derivative spectra is specific to the species of Fritillariae Bulbus. This indicates that the relative amount of protein and carbohydrate may be critical to identify Fritillariae Bulbus. With the help of the SIMCA model, the four kinds of Fritillariae Bulbus can be identified correctly by FT-NIR spectroscopy. The results show the potential of FT-NIR spectroscopy with a reflection fiber probe in the rapid testing and identification of Fritillariae Bulbus.
Martinez, N. E.; Sharp, J. L.; Kuhne, W. W.; ...
2015-11-23
Here, reflectance spectroscopy is a rapid and non-destructive analytical technique that may be used for assessing plant stress, and has potential applications for use in remediation. Changes in reflectance such as that due to metal stress may occur before damage is visible, and existing studies have shown that metal stress does cause changes in plant reflectance. To further investigate the potential use of reflectance spectroscopy as a method for assessing metal stress in plants, an exploratory study was conducted in which Arabidopsis thaliana plants were treated twice weekly in a laboratory setting with varying levels (0, 0.5, or 5 mMmore » (millimolar)) of caesium chloride (CsCl) solution, and reflectance spectra were collected every week for three weeks using an Analytical Spectral Devices FieldSpec Pro spectroradiometer with both a contact probe (CP) and a field of view (FOV) probe at 36.8 and 66.7 cm, respectively, above the plant. Plants were harvested each week after spectra collection for determination of relative water content and chlorophyll content. A visual assessment of the plants was also conducted using point observations on a uniform grid of 81 points. A mixed-effects model analysis was conducted for each vegetation index (VI) considered to determine the effects of length of treatment, treatment level, view with which spectra were acquired, and the interactions of these terms. Two-way analyses of variance (ANOVAs) were performed on the aforementioned endpoints (e.g. chlorophyll content) to determine the significance of the effects of treatment level and length of treatment. Multiple linear regression (MLR) was used to develop a predictive model for each endpoint, considering VI acquired at each view (CP, high FOV, and low FOV). Of the 14 VI considered, 8 were included in the MLR models. Contact probe readings and FOV readings differed significantly, but FOV measurements were generally consistent at each height.« less
Hsieh, Hong-Po; Ko, Fan-Hua; Sung, Kung-Bin
2018-04-20
An iterative curve fitting method has been applied in both simulation [J. Biomed. Opt.17, 107003 (2012)JBOPFO1083-366810.1117/1.JBO.17.10.107003] and phantom [J. Biomed. Opt.19, 077002 (2014)JBOPFO1083-366810.1117/1.JBO.19.7.077002] studies to accurately extract optical properties and the top layer thickness of a two-layered superficial tissue model from diffuse reflectance spectroscopy (DRS) data. This paper describes a hybrid two-step parameter estimation procedure to address two main issues of the previous method, including (1) high computational intensity and (2) converging to local minima. The parameter estimation procedure contained a novel initial estimation step to obtain an initial guess, which was used by a subsequent iterative fitting step to optimize the parameter estimation. A lookup table was used in both steps to quickly obtain reflectance spectra and reduce computational intensity. On simulated DRS data, the proposed parameter estimation procedure achieved high estimation accuracy and a 95% reduction of computational time compared to previous studies. Furthermore, the proposed initial estimation step led to better convergence of the following fitting step. Strategies used in the proposed procedure could benefit both the modeling and experimental data processing of not only DRS but also related approaches such as near-infrared spectroscopy.
Gómez, Nuria; Molleda, Cristina; Quintana, Ester; Carbajo, José M; Rodríguez, Alejandro; Villar, Juan C
2016-09-01
A new method was developed to study how the oil and cyan pigments of cold-set ink are distributed in newspaper thickness. The methodology involved laboratory printing followed by delamination of the printed paper. The unprinted side, printed side, and resulting layers were analyzed using attenuated total reflection Fourier transform infrared spectroscopy (ATR FT-IR). Three commercial newspapers and black and cyan cold-set inks were chosen for the study. Attenuated total reflection Fourier transform infrared spectroscopy enabled the proportion of oil and cyan pigment on the printed surface and throughout the sheet thickness to be measured. Oil percentage was evaluated as the area increment of the region from 2800 cm(-1) to 3000 cm(-1) The relative amount of cyan pigment was determined as the area of the absorption band at 730 cm(-1) The ink oil was found mainly below half the paper thickness, whereas the pigment was detected at the layers closer to the printed surface, at a depth penetration of less than 15 µm (20% of thickness). Distribution of these two components in paper thickness depended on the type of cold-set ink, the amount of ink transferred, and the newspaper properties. © The Author(s) 2016.
Applications of fourier transform infrared spectroscopy to surface analysis problems 2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Powell, G.L.; Milosevic, M.
Applications of infrared spectroscopy to surface analysis are described in terms of the combined use of a number of techniques to solve specific surface analysis problems involving both qualitative and quantitative analysis of surface species. Emphasis is placed on the characterization of both the substrate and the surface species and the application of this to the monitoring of surface processes and the inspection of manufactured items. Lithium Hydride has been studied using remote analysis by diffuse reflectance in glove boxes containing very pure argon or controlled moisture levels with robot-operated gravimetric monitoring. These experiments are supported by internal reflectance andmore » diffuse reflectance measurements in spectrometer sample compartments to characterize the reactants. Beryllium oxide has been studied using an evacuable diffuse reflectance cell to determine the effects of vacuum baking reexposure to moisture on the surface hydroxyl species. Diffuse reflectance and emission measurements have been used to monitor the curing and reaction of environmental gases with composite materials such as graphite-expoxy structures. A direct comparison of diffuse reflectance and emission spectra was done using a barrel ellipsoid diffuse reflectance/emission detector and Spectropus optical transfer system. Grazing-incidence external-reflectance with p-polarized light was used to study the oxidation in room air of polished uranium coupons. The absorption band at 570 cm{sup {minus}1} was used to monitor the extent of oxidation with a resolution of approximately one monolayer of UO{sub 2} and to distinguish the parabolic, linear, and breakaway corrosion domains. External reflectance is compared with diffuse reflectance as a method for stain analysis and for measuring the effects of H{sub 2}O in UO{sub 2} corrosion films.« less
Applications of fourier transform infrared spectroscopy to surface analysis problems 2. Revision 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Powell, G.L.; Milosevic, M.
Applications of infrared spectroscopy to surface analysis are described in terms of the combined use of a number of techniques to solve specific surface analysis problems involving both qualitative and quantitative analysis of surface species. Emphasis is placed on the characterization of both the substrate and the surface species and the application of this to the monitoring of surface processes and the inspection of manufactured items. Lithium Hydride has been studied using remote analysis by diffuse reflectance in glove boxes containing very pure argon or controlled moisture levels with robot-operated gravimetric monitoring. These experiments are supported by internal reflectance andmore » diffuse reflectance measurements in spectrometer sample compartments to characterize the reactants. Beryllium oxide has been studied using an evacuable diffuse reflectance cell to determine the effects of vacuum baking reexposure to moisture on the surface hydroxyl species. Diffuse reflectance and emission measurements have been used to monitor the curing and reaction of environmental gases with composite materials such as graphite-expoxy structures. A direct comparison of diffuse reflectance and emission spectra was done using a barrel ellipsoid diffuse reflectance/emission detector and Spectropus optical transfer system. Grazing-incidence external-reflectance with p-polarized light was used to study the oxidation in room air of polished uranium coupons. The absorption band at 570 cm{sup {minus}1} was used to monitor the extent of oxidation with a resolution of approximately one monolayer of UO{sub 2} and to distinguish the parabolic, linear, and breakaway corrosion domains. External reflectance is compared with diffuse reflectance as a method for stain analysis and for measuring the effects of H{sub 2}O in UO{sub 2} corrosion films.« less
Brain tumor imaging of rat fresh tissue using terahertz spectroscopy
NASA Astrophysics Data System (ADS)
Yamaguchi, Sayuri; Fukushi, Yasuko; Kubota, Oichi; Itsuji, Takeaki; Ouchi, Toshihiko; Yamamoto, Seiji
2016-07-01
Tumor imaging by terahertz spectroscopy of fresh tissue without dye is demonstrated using samples from a rat glioma model. The complex refractive index spectrum obtained by a reflection terahertz time-domain spectroscopy system can discriminate between normal and tumor tissues. Both the refractive index and absorption coefficient of tumor tissues are higher than those of normal tissues and can be attributed to the higher cell density and water content of the tumor region. The results of this study indicate that terahertz technology is useful for detecting brain tumor tissue.
Ricci, Arianna; Parpinello, Giuseppina P; Olejar, Kenneth J; Kilmartin, Paul A; Versari, Andrea
2015-11-01
Attenuated total reflection Fourier transform infrared (FT-IR) spectroscopy was used to characterize 40 commercial tannins, including condensed and hydrolyzable chemical classes, provided as powder extracts from suppliers. Spectral data were processed to detect typical molecular vibrations of tannins bearing different chemical groups and of varying botanical origin (univariate qualitative analysis). The mid-infrared region between 4000 and 520 cm(-1) was analyzed, with a particular emphasis on the vibrational modes in the fingerprint region (1800-520 cm(-1)), which provide detailed information about skeletal structures and specific substituents. The region 1800-1500 cm(-1) contained signals due to hydrolyzable structures, while bands due to condensed tannins appeared at 1300-900 cm(-1) and exhibited specific hydroxylation patterns useful to elucidate the structure of the flavonoid monomeric units. The spectra were investigated further using principal component analysis for discriminative purposes, to enhance the ability of infrared spectroscopy in the classification and quality control of commercial dried extracts and to enhance their industrial exploitation.
Yue, Zheng-Bo; Zhang, Meng-Lin; Sheng, Guo-Ping; Liu, Rong-Hua; Long, Ying; Xiang, Bing-Ren; Wang, Jin; Yu, Han-Qing
2010-04-01
A near-infrared-reflectance (NIR) spectroscopy-based method is established to determine the main components of aquatic plants as well as their anaerobic rumen biodegradability. The developed method is more rapid and accurate compared to the conventional chemical analysis and biodegradability tests. Moisture, volatile solid, Klason lignin and ash in entire aquatic plants could be accurately predicted using this method with coefficient of determination (r(2)) values of 0.952, 0.916, 0.939 and 0.950, respectively. In addition, the anaerobic rumen biodegradability of aquatic plants, represented as biogas and methane yields, could also be predicted well. The algorithm of continuous wavelet transform for the NIR spectral data pretreatment is able to greatly enhance the robustness and predictive ability of the NIR spectral analysis. These results indicate that NIR spectroscopy could be used to predict the main components of aquatic plants and their anaerobic biodegradability. Copyright (c) 2009 Elsevier Ltd. All rights reserved.
On the origin of reflectance-anisotropy oscillations during GaAs (0 0 1) homoepitaxy
NASA Astrophysics Data System (ADS)
Ortega-Gallegos, J.; Guevara-Macías, L. E.; Ariza-Flores, A. D.; Castro-García, R.; Lastras-Martínez, L. F.; Balderas-Navarro, R. E.; López-Estopier, R. E.; Lastras-Martínez, A.
2018-05-01
We report on the first spectroscopic study of reflectance-anisotropy (RA) oscillations during molecular beam epitaxy (MBE) GaAs homoepitaxy. Real-time RA spectra measured during epitaxial growth were carried out with a recently developed rapid RA multichannel spectrometer with 100 ms per spectrum acquisition time. An analysis of the time-resolved RA spectra shows that RA oscillations are mostly due to the periodic modulation of the surface orthorhombic strain associated to surface reconstruction. Results reported here demonstrate the power of real-time RA spectroscopy as a probe for the study of epitaxial growth processes. In particular, given its sub monolayer surface-strain sensitivity, RA spectroscopy results a very convenient tool to study epitaxial growth mechanisms in real-time with sub monolayer resolution. This capability allows for real-time RA spectroscopy to be used as a probe for the in situ, real-time control of epitaxial growth, with the additional advantage of operating in higher pressure systems such as CVD, where RHEED monitoring cannot be implemented.
Dooley, Kathryn A; Conover, Damon M; Glinsman, Lisha Deming; Delaney, John K
2014-12-08
Two imaging modalities based on molecular and elemental spectroscopy were used to characterize a painting by Cosimo Tura. Visible-to-near-infrared (400-1680 nm) reflectance imaging spectroscopy (RIS) and X-ray fluorescence (XRF) imaging spectroscopy were employed to identify pigments and determine their spatial distribution with higher confidence than from either technique alone. For example, Mary's red robe was modeled through the distribution of an insect-derived red lake (RIS map) and lead white (XRF lead map), rather than a layer of red lake on vermilion. The RIS image cube was also used to isolate the preparatory design by mapping the reflectance spectra associated with it. In conjunction with results from an earlier RIS study (1650-2500 nm) to map and identify the binding media, a more thorough understanding was gained of the materials and techniques used in the painting. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hierlemann, A.; Hill, M.; Ricco, A.J.
We have developed instrumentation to enable the combination of surface acoustic wave (SAW) sensor measurements with direct, in-situ molecular spectroscopic measurements to understand the response of the SAW sensors with respect to the interfacial chemistry of surface-confined sensing films interacting with gas-phase analytes. Specifically, the instrumentation and software was developed to perform in-situ Fourier-transform infrared external-reflectance spectroscopy (FTIR-ERS) on operating SAW devices during dosing of their chemically modified surfaces with analytes. By probing the surface with IR spectroscopy during gas exposure, it is possible to understand in unprecedented detail the interaction processes between the sorptive SAW coatings and the gaseousmore » analyte molecules. In this report, we provide details of this measurement system, and also demonstrate the utility of these combined measurements by characterizing the SAW and FTIR-ERS responses of organic thin-film sensor coatings interacting with gas-phase analytes.« less
NASA Astrophysics Data System (ADS)
Shi, L.; Wang, Y.; Liu, X.; Mao, J.
2018-03-01
Raman spectroscopy, ultraviolet, visible, and near infrared (UV-Vis-NIR) reflectance spectroscopy, and X-ray fluorescence (XRF) spectroscopy were used to characterize black Tahitian cultured pearls and imitations of these saltwater cultured pearls produced by γ-irradiation, and by coloring of cultured pearls with silver nitrate or organic dyes. Raman spectra indicated that aragonite was the major constituent of these four types of pearl. Using Raman spectroscopy at an excitation wavelength of 514 nm, black Tahitian cultured pearls exhibited characteristic 1100-1700 cm-1 bands. These bands were attributed to various organic components, including conchiolin and other black biological pigments. The peaks shown by saltwater cultured pearls colored with organic dyes varied with the type of dye used. Tahitian cultured and organic-dye-treated saltwater cultured pearls were easily identified by Raman spectroscopy. UV-Vis-NIR reflectance spectra showed bands at 408, 497, and 700 nm derived from porphyrin pigment and other black pigments. The spectra of dye-treated black saltwater pearls showed absorption peaks at 216, 261, 300, and 578 nm. The 261-nm absorption band disappeared from the spectra of γ-irradiated saltwater cultured pearls. This suggests the degradation of conchiolin in the γ-irradiated saltwater cultured pearls. XRF analysis revealed the presence of Ag on the surface of silver nitrate-dyed saltwater cultured pearls.
Linker, Raphael; Etzion, Yael
2009-02-01
Real-time information about milk composition would be very useful for managing the milking process. Mid-infrared spectroscopy, which relies on fundamental modes of molecular vibrations, is routinely used for off-line analysis of milk and the purpose of the present study was to investigate the potential of attenuated total reflectance mid-infrared spectroscopy for real-time analysis of milk in milking lines. The study was conducted with 189 samples from over 70 cows that were collected during an 18 months period. Principal component analysis, wavelets and neural networks were used to develop various models for predicting protein and fat concentration. Although reasonable protein models were obtained for some seasonal sub-datasets (determination errors
NASA Astrophysics Data System (ADS)
Loring, J. S.; Thompson, C. J.; Wang, Z.; Schaef, H. T.; Martin, P.; Qafoku, O.; Felmy, A. R.; Rosso, K. M.
2011-12-01
Geologic sequestration of carbon dioxide holds promise for helping mitigate CO2 emissions generated from the burning of fossil fuels. Supercritical CO2 (scCO2) plumes containing variable water concentrations (wet scCO2) will displace aqueous solution and dominate the pore space adjacent to caprocks. It is important to understand possible mineral reactions with wet scCO2 to better predict long-term caprock integrity. We introduce novel in situ instrumentation that enables quantitative titrations of reactant minerals with water in scCO2 at temperatures and pressures relevant to target geologic reservoirs. The system includes both transmission and attenuated total reflection mid-infrared optics. Transmission infrared spectroscopy is used to measure concentrations of water dissolved in the scCO2, adsorbed on mineral surfaces, and incorporated into precipitated carbonates. Single-reflection attenuated total reflection infrared spectroscopy is used to monitor water adsorption, mineral dissolution, and carbonate precipitation reactions. Results are presented for the infrared spectroscopic titration of forsterite (Mg2SiO4), a model divalent metal silicate, with water in scCO2 at 100 bar and at both 50 and 75°C. The spectral data demonstrate that the quantitative speciation of water as either dissolved or adsorbed is important for understanding the types, growth rates, and amounts of carbonate precipitates formed. Relationships between dissolved/adsorbed water, water concentrations, and the role of liquid-like adsorbed water are discussed. Our results unify previous in situ studies from our laboratory based on infrared spectroscopy, nuclear magnetic resonance spectroscopy and X-ray diffraction.
Elsohaby, Ibrahim; Hou, Siyuan; McClure, J Trenton; Riley, Christopher B; Shaw, R Anthony; Keefe, Gregory P
2015-08-20
Following the recent development of a new approach to quantitative analysis of IgG concentrations in bovine serum using transmission infrared spectroscopy, the potential to measure IgG levels using technology and a device better designed for field use was investigated. A method using attenuated total reflectance infrared (ATR) spectroscopy in combination with partial least squares (PLS) regression was developed to measure bovine serum IgG concentrations. ATR spectroscopy has a distinct ease-of-use advantage that may open the door to routine point-of-care testing. Serum samples were collected from calves and adult cows, tested by a reference RID method, and ATR spectra acquired. The spectra were linked to the RID-IgG concentrations and then randomly split into two sets: calibration and prediction. The calibration set was used to build a calibration model, while the prediction set was used to assess the predictive performance and accuracy of the final model. The procedure was repeated for various spectral data preprocessing approaches. For the prediction set, the Pearson's and concordance correlation coefficients between the IgG measured by RID and predicted by ATR spectroscopy were both 0.93. The Bland Altman plot revealed no obvious systematic bias between the two methods. ATR spectroscopy showed a sensitivity for detection of failure of transfer of passive immunity (FTPI) of 88 %, specificity of 100 % and accuracy of 94 % (with IgG <1000 mg/dL as the FTPI cut-off value). ATR spectroscopy in combination with multivariate data analysis shows potential as an alternative approach for rapid quantification of IgG concentrations in bovine serum and the diagnosis of FTPI in calves.
Development and implementation of software systems for imaging spectroscopy
Boardman, J.W.; Clark, R.N.; Mazer, A.S.; Biehl, L.L.; Kruse, F.A.; Torson, J.; Staenz, K.
2006-01-01
Specialized software systems have played a crucial role throughout the twenty-five year course of the development of the new technology of imaging spectroscopy, or hyperspectral remote sensing. By their very nature, hyperspectral data place unique and demanding requirements on the computer software used to visualize, analyze, process and interpret them. Often described as a marriage of the two technologies of reflectance spectroscopy and airborne/spaceborne remote sensing, imaging spectroscopy, in fact, produces data sets with unique qualities, unlike previous remote sensing or spectrometer data. Because of these unique spatial and spectral properties hyperspectral data are not readily processed or exploited with legacy software systems inherited from either of the two parent fields of study. This paper provides brief reviews of seven important software systems developed specifically for imaging spectroscopy.
Why Do Marbles Become Paler on Grinding? Reflectance, Spectroscopy, Color, and Particle Size
ERIC Educational Resources Information Center
Lagorio, Maria Gabriela
2004-01-01
A qualitative description of the color-change problem, which will assist in rationalizing the change in color of marbles after grinding them using a simple physical picture and the qualitative dependence of diffuse reflectance on particle size is presented. Different approaches are discussed but it is seen that the interpretation of nanoparticles…
Identification of mineral composition and weathering product of tuff using reflectance spectroscopy
NASA Astrophysics Data System (ADS)
Hyun, C.; Park, H.
2009-12-01
Tuff is intricately composed of various types of rock blocks and ash matrixes during volcanic formation processes. Qualitative identification and quantitative assessment of mineral composition of tuff usually have been done using manual inspection with naked-eyes and various chemical analyses. Those conventional methods are destructive to objects, time consuming and sometimes carry out biased results from subjective decision making. To overcome limits from conventional methods, assessment technique using reflectance spectroscopy was applied to tuff specimens. Reflectance spectroscopy measures electromagnetic reflectance on rock surface and can extract diagnostic absorption features originated from chemical composition and crystal structure of constituents in the reflectance curve so mineral species can be discriminated qualitatively. The intrinsic absorption feature from particular mineral can be converted to absorption depth representing relative coverage of the mineral in the measurement area by removing delineated convex hull from raw reflectance curve. The spectral measurements were performed with field spectrometer FieldSpec®3 of ASD Inc. and the wavelength range of measurement was form 350nm to 2500nm. Three types of tuff blocks, ash tuff, green lapilli tuff and red lapilli tuff, were sampled from Hwasun County in Korea and the types of tuffs. The differences between green tuff and red tuff are from the color of their matrixes. Ash tuff consists of feldspars and quartz and small amount of chalcedony, calcite, dolomite, epidote and basalt fragments. Green lapilli tuff consists of feldspar, quartz and muscovite and small amount of calcite, chalcedony, sericite, chlorite, quartzite and basalt fragments. Red lapilli tuff consists of feldspar, quartz and muscovite and small amount of calcite, chalcedony, limonite, zircon, chlorite, quartzite and basalt fragments. The tuff rocks were coarsely crushed and blocks and matrixes were separated to measure standard spectral reflectance of each constituent. Unmixing of mineral composition and their weathering products of blocks and matrixes in tuff were conducted and the ratio of mineral composition was calculated for each specimen. This study was supported by National Research Institute of Cultural Heritage (project title: Development on Evaluation Technology for Weathering Degree of Stone Cultural Properties, project no.: 09B011Y-00150-2009).
NASA Astrophysics Data System (ADS)
Nakamura, Takako; Ohana, Tsuguyori; Yabuno, Hajime; Kasai, Rumiko; Suzuki, Tetsuya; Hasebe, Terumitsu
2013-01-01
We have developed a simple and useful process for fabricating nanodiamond (ND) particles modified with an organogadolinium moiety by chemical modification for their use as a magnetic resonance imaging (MRI) contrast agent. The introduction of the organogadolinium moiety on the surface of the ND particles was performed by the condensation of ND and diethylenetriaminepentaacetic acid (DTPA) followed by treatment with GdCl3. The modified surfaces were evaluated by X-ray photoelectron spectroscopy, diffuse reflectance Fourier transform infrared spectroscopy, mass spectroscopy, and inductively coupled plasma atomic emission spectroscopy analyses. MRI experiments on the Gd-DTPA-ND particles indicated their high signal intensity on T1-weighted images.
Interfacial structure of soft matter probed by SFG spectroscopy.
Ye, Shen; Tong, Yujin; Ge, Aimin; Qiao, Lin; Davies, Paul B
2014-10-01
Sum frequency generation (SFG) vibrational spectroscopy, an interface-specific technique in contrast to, for example, attenuated total reflectance spectroscopy, which is only interface sensitive, has been employed to investigate the surface and interface structure of soft matter on a molecular scale. The experimental arrangement required to carry out SFG spectroscopy, with particular reference to soft matter, and the analytical methods developed to interpret the spectra are described. The elucidation of the interfacial structure of soft matter systems is an essential prerequisite in order to understand and eventually control the surface properties of these important functional materials. Copyright © 2014 The Chemical Society of Japan and Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Catheter based mid-infrared reflectance and reflectance generated absorption spectroscopy
Holman, Hoi-Ying N
2013-10-29
A method of characterizing conditions in a tissue, by (a) providing a catheter that has a light source that emits light in selected wavenumbers within the range of mid-IR spectrum; (b) directing the light from the catheter to an area of tissue at a location inside a blood vessel of a subject; (c) collecting light reflected from the location and generating a reflectance spectra; and (d) comparing the reflectance spectra to a reference spectra of normal tissue, whereby a location having an increased number of absorbance peaks at said selected wavenumbers indicates a tissue inside the blood vessel containing a physiological marker for atherosclerosis.
Light distribution modulated diffuse reflectance spectroscopy.
Huang, Pin-Yuan; Chien, Chun-Yu; Sheu, Chia-Rong; Chen, Yu-Wen; Tseng, Sheng-Hao
2016-06-01
Typically, a diffuse reflectance spectroscopy (DRS) system employing a continuous wave light source would need to acquire diffuse reflectances measured at multiple source-detector separations for determining the absorption and reduced scattering coefficients of turbid samples. This results in a multi-fiber probe structure and an indefinite probing depth. Here we present a novel DRS method that can utilize a few diffuse reflectances measured at one source-detector separation for recovering the optical properties of samples. The core of innovation is a liquid crystal (LC) cell whose scattering property can be modulated by the bias voltage. By placing the LC cell between the light source and the sample, the spatial distribution of light in the sample can be varied as the scattering property of the LC cell modulated by the bias voltage, and this would induce intensity variation of the collected diffuse reflectance. From a series of Monte Carlo simulations and phantom measurements, we found that this new light distribution modulated DRS (LDM DRS) system was capable of accurately recover the absorption and scattering coefficients of turbid samples and its probing depth only varied by less than 3% over the full bias voltage variation range. Our results suggest that this LDM DRS platform could be developed to various low-cost, efficient, and compact systems for in-vivo superficial tissue investigation.
Light distribution modulated diffuse reflectance spectroscopy
Huang, Pin-Yuan; Chien, Chun-Yu; Sheu, Chia-Rong; Chen, Yu-Wen; Tseng, Sheng-Hao
2016-01-01
Typically, a diffuse reflectance spectroscopy (DRS) system employing a continuous wave light source would need to acquire diffuse reflectances measured at multiple source-detector separations for determining the absorption and reduced scattering coefficients of turbid samples. This results in a multi-fiber probe structure and an indefinite probing depth. Here we present a novel DRS method that can utilize a few diffuse reflectances measured at one source-detector separation for recovering the optical properties of samples. The core of innovation is a liquid crystal (LC) cell whose scattering property can be modulated by the bias voltage. By placing the LC cell between the light source and the sample, the spatial distribution of light in the sample can be varied as the scattering property of the LC cell modulated by the bias voltage, and this would induce intensity variation of the collected diffuse reflectance. From a series of Monte Carlo simulations and phantom measurements, we found that this new light distribution modulated DRS (LDM DRS) system was capable of accurately recover the absorption and scattering coefficients of turbid samples and its probing depth only varied by less than 3% over the full bias voltage variation range. Our results suggest that this LDM DRS platform could be developed to various low-cost, efficient, and compact systems for in-vivo superficial tissue investigation. PMID:27375931
Liu, Jui-Nung; Schulmerich, Matthew V.; Bhargava, Rohit; Cunningham, Brian T.
2011-01-01
An alternative to the well-established Fourier transform infrared (FT-IR) spectrometry, termed discrete frequency infrared (DFIR) spectrometry, has recently been proposed. This approach uses narrowband mid-infrared reflectance filters based on guided-mode resonance (GMR) in waveguide gratings, but filters designed and fabricated have not attained the spectral selectivity (≤ 32 cm−1) commonly employed for measurements of condensed matter using FT-IR spectroscopy. With the incorporation of dispersion and optical absorption of materials, we present here optimal design of double-layer surface-relief silicon nitride-based GMR filters in the mid-IR for various narrow bandwidths below 32 cm−1. Both shift of the filter resonance wavelengths arising from the dispersion effect and reduction of peak reflection efficiency and electric field enhancement due to the absorption effect show that the optical characteristics of materials must be taken into consideration rigorously for accurate design of narrowband GMR filters. By incorporating considerations for background reflections, the optimally designed GMR filters can have bandwidth narrower than the designed filter by the antireflection equivalence method based on the same index modulation magnitude, without sacrificing low sideband reflections near resonance. The reported work will enable use of GMR filters-based instrumentation for common measurements of condensed matter, including tissues and polymer samples. PMID:22109445
Pomerantsev, Alexey L; Rodionova, Oxana Ye; Skvortsov, Alexej N
2017-08-01
Investigation of a sample covered by an interfering layer is required in many fields, e.g., for process control, biochemical analysis, and many other applications. This study is based on the analysis of spectra collected by near-infrared (NIR) diffuse reflectance spectroscopy. Each spectrum is a composition of a useful, target spectrum and a spectrum of an interfering layer. To recover the target spectrum, we suggest using a new phenomenological approach, which employs the multivariate curve resolution (MCR) method. In general terms, the problem is very complex. We start with a specific problem of analyzing a system, which consists of several layers of polyethylene (PE) film and underlayer samples with known spectral properties. To separate information originating from PE layers and the target, we modify the system versus both the number of the PE layers as well as the reflectance properties of the target sample. We consider that the interfering spectrum of the layer can be modeled using three components, which can be tentatively called transmission, absorption, and scattering contributions. The novelty of our approach is that we do not remove the reflectance and scattering effects from the spectra, but study them in detail aiming to use this information to recover the target spectrum.
Spectral features of biogenic calcium carbonates and implications for astrobiology
NASA Astrophysics Data System (ADS)
Berg, B. L.; Ronholm, J.; Applin, D. M.; Mann, P.; Izawa, M.; Cloutis, E. A.; Whyte, L. G.
2014-09-01
The ability to discriminate biogenic from abiogenic calcium carbonate (CaCO3) would be useful in the search for extant or extinct life, since CaCO3 can be produced by both biotic and abiotic processes on Earth. Bioprecipitated CaCO3 material was produced during the growth of heterotrophic microbial isolates on medium enriched with calcium acetate or calcium citrate. These biologically produced CaCO3, along with natural and synthetic non-biologically produced CaCO3 samples, were analysed by reflectance spectroscopy (0.35-2.5 μm), Raman spectroscopy (532 and 785 nm), and laser-induced fluorescence spectroscopy (365 and 405 nm excitation). Optimal instruments for the discrimination of biogenic from abiogenic CaCO3 were determined to be reflectance spectroscopy, and laser-induced fluorescence spectroscopy. Multiple absorption features in the visible light region occurred in reflectance spectra for most biogenic CaCO3 samples, which are likely due to organic pigments. Multiple fluorescence peaks occurred in emission spectra (405 nm excitation) of biogenic CaCO3 samples, which also are best attributed to the presence of organic compounds; however, further analyses must be performed in order to better determine the cause of these features to establish criteria for confirming the origin of a given CaCO3 sample. Raman spectroscopy was not useful for discrimination since any potential Raman peaks in spectra of biogenic carbonates collected by both the 532 and 785 nm lasers were overwhelmed by fluorescence. However, this also suggests that biogenic carbonates may be identified by the presence of this organic-associated fluorescence. No reliable spectroscopic differences in terms of parameters such as positions or widths of carbonate-associated absorption bands were found between the biogenic and abiogenic carbonate samples. These results indicate that the presence or absence of organic matter intimately associated with carbonate minerals is the only potentially useful spectral discriminator for the techniques that were examined, and that multiple spectroscopic techniques are capable of detecting the presence of associated organic materials. However, the presence or absence of intimately associated organic matter is not, in itself, an indicator of biogenicity.
NASA Astrophysics Data System (ADS)
Siddique, M. Naseem; Ahmed, Ateeq; Ali, T.; Tripathi, P.
2018-05-01
Nickel oxide (NiO) nanoparticles with a crystal size of around 16.26 nm have been synthesized via sol-gel method. The synthesized precursor was calcined at 600 °C for 4 hours to obtain the nickel oxide nanoparticles. The XRD analysis result indicated that the calcined sample has a cubic structure without any impurity phases. The FTIR analysis result confirmed the formation of NiO. The NiO nanoparticle exhibited absorption band edge at 277.27 nm and the optical band gap have been estimated approximately 4.47 eV using diffuse reflectance spectroscopy and photoluminescence emission spectrum of our as-synthesized sample showed strong peak at 3.65 eV attributed to the band edge transition.
NASA Astrophysics Data System (ADS)
Carlson, Scott M.
1993-06-01
The design of a high resolution plane grating all-reflection Michelson interferometer for ionospheric spectroscopy was analyzed using ray tracing techniques. This interferometer produces an interference pattern whose spatial frequency is wavelength dependent. The instrument is intended for remote observations of the atomic oxygen triplet emission line profile at 1304 A in the thermosphere from sounding rocket or satellite platforms. The device was modeled using the PC-based ray tracing application, DART, and results analyzed through fourier techniques using the PC with Windows version of the Interactive Data Language (IDL). Through these methods, instrument resolution, resolving power, and bandpass were determined. An analysis of the effects of aperture size and shape on instrument performance was also conducted.
NASA Astrophysics Data System (ADS)
Zhang, Zhenxin; Huang, Kaijin; Yuan, Fangli; Xie, Changsheng
2014-05-01
The detection of trichloroethylene has attracted much attention because it has an important effect on human health. The sensitivity of the SnO2 flat-type coplanar gas sensor arrays to 100 ppm trichloroethylene in air was investigated. The adsorption and surface reactions of trichloroethylene were investigated at 100-200 °C by in-situ diffuse reflection Fourier transform infrared spectroscopy (DIRFTS) on SnO2 films. Molecularly adsorbed trichloroethylene, dichloroacetyl chloride (DCAC), phosgene, HCl, CO, H2O, CHCl3, Cl2 and CO2 surface species are formed during trichloroethylene adsorption at 100-200 °C. A possible mechanism of the reaction process is discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pavlikov, A. V., E-mail: pavlikov@physics.msu.ru; Latukhina, N. V.; Chepurnov, V. I.
Silicon-carbide (SiC) nanowire structures 40–50 nm in diameter are produced by the high-temperature carbonization of porous silicon and silicon nanowires. The SiC nanowires are studied by scanning electron microscopy, X-ray diffraction analysis, Raman spectroscopy, and infrared reflectance spectroscopy. The X-ray structural and Raman data suggest that the cubic 3C-SiC polytype is dominant in the samples under study. The shape of the infrared reflectance spectrum in the region of the reststrahlen band 800–900 cm{sup –1} is indicative of the presence of free charge carriers. The possibility of using SiC nanowires in microelectronic, photonic, and gas-sensing devices is discussed.
NASA Astrophysics Data System (ADS)
Verdel, Nina; Marin, Ana; Vidovič, Luka; Milanič, Matija; Majaron, Boris
2017-07-01
We present a novel methodology for quantitative analysis of hemodynamics in human skin in vivo. Our approach combines pulsed photothermal radiometry (i.e., time-resolved measurements of midinfrared emission from sample surface after exposure to a short light pulse) and diffuse reflectance spectroscopy in visible part of the spectrum. Experimental data are fitted with predictions of a numerical model of light transport in a four-layer skin model (i.e., inverse Monte Carlo), which allows assessment of the layer thicknesses, chromophore contents (e.g., melanin, oxy- and deoxy-hemoglobin), as well as scattering properties. The performance is tested in comparison analysis of healthy skin before and during application of a blood pressure cuff (at 200 mm Hg) for 5 minutes.
NASA Astrophysics Data System (ADS)
Vidovič, Luka; Milanič, Matija; Majaron, Boris
2015-07-01
We combine pulsed photothermal radiometry (PPTR) depth profiling with diffuse reflectance spectroscopy (DRS) measurements for a comprehensive analysis of bruise evolution in vivo. While PPTR enables extraction of detailed depth distribution and concentration profiles of selected absorbers (e.g. melanin, hemoglobin), DRS provides information in a wide range of visible wavelengths and thus offers an additional insight into dynamics of the hemoglobin degradation products. Combining the two approaches enables us to quantitatively characterize bruise evolution dynamics. Our results indicate temporal variations of the bruise evolution parameters in the course of bruise self-healing process. The obtained parameter values and trends represent a basis for a future development of an objective technique for bruise age determination.
Rodriguez-Saona, L E; Koca, N; Harper, W J; Alvarez, V B
2006-05-01
There is a need for rapid and simple techniques that can be used to predict the quality of cheese. The aim of this research was to develop a simple and rapid screening tool for monitoring Swiss cheese composition by using Fourier transform infrared spectroscopy. Twenty Swiss cheese samples from different manufacturers and degree of maturity were evaluated. Direct measurements of Swiss cheese slices (approximately 0.5 g) were made using a MIRacle 3-reflection diamond attenuated total reflectance (ATR) accessory. Reference methods for moisture (vacuum oven), protein content (Kjeldahl), and fat (Babcock) were used. Calibration models were developed based on a cross-validated (leave-one-out approach) partial least squares regression. The information-rich infrared spectral range for Swiss cheese samples was from 3,000 to 2,800 cm(-1) and 1,800 to 900 cm(-1). The performance statistics for cross-validated models gave estimates for standard error of cross-validation of 0.45, 0.25, and 0.21% for moisture, protein, and fat respectively, and correlation coefficients r > 0.96. Furthermore, the ATR infrared protocol allowed for the classification of cheeses according to manufacturer and aging based on unique spectral information, especially of carbonyl groups, probably due to their distinctive lipid composition. Attenuated total reflectance infrared spectroscopy allowed for the rapid (approximately 3-min analysis time) and accurate analysis of the composition of Swiss cheese. This technique could contribute to the development of simple and rapid protocols for monitoring complex biochemical changes, and predicting the final quality of the cheese.
Advances in photo-thermal infrared imaging microspectroscopy
NASA Astrophysics Data System (ADS)
Furstenberg, Robert; Kendziora, Chris; Papantonakis, Michael; Nguyen, Viet; McGill, Andrew
2013-05-01
There is a growing need for chemical imaging techniques in many fields of science and technology: forensics, materials science, pharmaceutical and chemical industries, just to name a few. While FTIR micro-spectroscopy is commonly used, its practical resolution limit of about 20 microns or more is often insufficient. Raman micro-spectroscopy provides better spatial resolution (~1 micron), but is not always practical because of samples exhibiting fluorescence or low Raman scattering efficiency. We are developing a non-contact and non-destructive technique we call photo-thermal infrared imaging spectroscopy (PT-IRIS). It involves photo-thermal heating of the sample with a tunable quantum cascade laser and measuring the resulting increase in thermal emission with an infrared detector. Photo-thermal emission spectra resemble FTIR absorbance spectra and can be acquired in both stand-off and microscopy configurations. Furthermore, PT-IRIS allows the acquisition of absorbance-like photo-thermal spectra in a reflected geometry, suitable for field applications and for in-situ study of samples on optically IR-opaque substrates (metals, fabrics, paint, glass etc.). Conventional FTIR microscopes in reflection mode measure the reflectance spectra which are different from absorbance spectra and are usually not catalogued in FTIR spectral libraries. In this paper, we continue developing this new technique. We perform a series of numerical simulations of the laser heating of samples during photo-thermal microscopy. We develop parameterized formulas to help the user pick the appropriate laser illumination power. We also examine the influence of sample geometry on spectral signatures. Finally, we measure and compare photo-thermal and reflectance spectra for two test samples.
Rajic, Slobodan; Egert, Charles M.; Kahl, William K.; Snyder, Jr., William B.; Evans, III, Boyd M.; Marlar, Troy A.; Cunningham, Joseph P.
1998-01-01
A monolithic spectrometer is disclosed for use in spectroscopy. The spectrometer is a single body of translucent material with positioned surfaces for the transmission, reflection and spectral analysis of light rays.
NASA Astrophysics Data System (ADS)
Finnie, Kim S.; Zhang, Zhaoming; Vance, Eric R.; Carter, Melody L.
2003-04-01
The valence state of uranium doped into a f 0 thorium analog of brannerite (i.e., thorutite) has been examined using near-infrared (NIR) diffuse reflectance (DRS) and X-ray photoelectron (XPS) spectroscopies. NIR transitions of U 4+, which are not observed in spectra of brannerite, have been detected in the samples of U xTh 1- xTi 2O 6, and we propose that strong specular reflectance is responsible for the lack of U 4+ features in UTi 2O 6. Characteristic U 5+ bands have been identified in samples in which sufficient Ca 2+ has been added to nominally effect complete oxidation to U 5+. XPS results support the assignments of U 4+ and U 5+ by DRS. The presence of residual U 4+ bands in the spectra of the Ca-doped samples is consistent with segregation of Ca 2+ to the grain boundaries during high temperature sintering.
Sun, Yiwen; Yang, Shengxin; Du, Pengju; Yan, Fei; Qu, Junle; Zhu, Zexuan; Zuo, Jian; Zhang, Cunlin
2017-02-06
The conductivity of poly(3,4-ethylene dioxythiophene)/poly(4-styrenesulfonate) (PEDOT/PSS) is significantly enhanced on adding some organic solvent such as ethylene glycol (EG). In this paper, the optoelectronic properties of EG doped PEDOT/PSS on transmission and anti-reflection effects are investigated in detail by terahertz time domain spectroscopy (THz-TDS). The transmission line circuit theory gives us an insight into the THz transmission mechanisms of the main and second pulses. In particular, we show that the conductivities of 10% EG doped PEDOT/PSS are nearly frequency independent from 0.3 to 1.5 THz. To demonstrate applications of this property, we design and fabricate broadband terahertz neutral density filters and anti-reflection coatings based on 10% EG doped PEDOT/PSS thin films with varying thickness. Our measurements highlight the capability of THz-TDS to characterize the conductivity of EG doped PEDOT/PSS, which is essential for broadband optoelectronic devices in THz region.
Halide Ions Effects on Surface Excess of Long Chain Ionic Liquids Water Solutions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Wenjie; Sung, Woongmo; Ao, Mingqi
2013-10-07
The interfacial structure and composition of water solutions with alkylimidazolium ionic liquids varying in their halide anions ([C12mim][X], X = Cl and I) were investigated by X-ray near-total-reflection fluorescence spectroscopy and X-ray reflectivity measurements. We demonstrate that X-ray fluorescence and reflectivity techniques provide a more direct measurement of surface adsorption. Furthermore, we show that for [C12mim][Cl] and [C12mim][I] solutions with mixed inorganic salts (NaI, NaCl), I– ions replace Cl– above the critical micelle concentration (CMC) of [C12mim][Cl] at much lower concentrations of NaI, whereas NaCl concentrations a hundred times higher than the CMC of [C12mim][I] only partially replace the I–more » at the interface. Our surface-sensitive X-ray diffraction and spectroscopy provide two independent tools to directly determine the surface adsorption of ionic surfactants and the interfacial composition of the surface films.« less
NASA Astrophysics Data System (ADS)
Milanic, Matija; Marin, Ana; Stergar, Jost; Verdel, Nina; Majaron, Boris
2017-07-01
Caffeine is the most widely consumed psychoactive substance in the world. It affects many tissues and organs, in particular central nervous system, heart, and blood vessels. The effect of caffeine on vascular smooth muscle cells is an initial transient contraction followed by significant vasodilatation. In this study we investigate the use of diffuse reflectance spectroscopy (DRS) for monitoring of vascular changes in human skin induced by caffeine consumption. DRS spectra were recorded on volar sides of the forearms of ten healthy volunteers at time delays of 0, 30, 60, 120, and 180 minutes after consumption of caffeine, while one subject served as a negative control. Analytical diffusion approximation solutions for diffuse reflectance from three-layer structures were used to assess skin composition (e.g., dermal blood volume fraction and oxygen saturation) by fitting to experimental data. The results demonstrate that cutaneous vasodynamics induced by caffeine consumption can be monitored by DRS, while changes in the control subject not consuming caffeine were insignificant.
NASA Astrophysics Data System (ADS)
Cappon, Derek J.; Farrell, Thomas J.; Fang, Qiyin; Hayward, Joseph E.
2016-12-01
Optical spectroscopy of human tissue has been widely applied within the field of biomedical optics to allow rapid, in vivo characterization and analysis of the tissue. When designing an instrument of this type, an imaging spectrometer is often employed to allow for simultaneous analysis of distinct signals. This is especially important when performing spatially resolved diffuse reflectance spectroscopy. In this article, an algorithm is presented that allows for the automated processing of 2-dimensional images acquired from an imaging spectrometer. The algorithm automatically defines distinct spectrometer tracks and adaptively compensates for distortion introduced by optical components in the imaging chain. Crosstalk resulting from the overlap of adjacent spectrometer tracks in the image is detected and subtracted from each signal. The algorithm's performance is demonstrated in the processing of spatially resolved diffuse reflectance spectra recovered from an Intralipid and ink liquid phantom and is shown to increase the range of wavelengths over which usable data can be recovered.
NASA Astrophysics Data System (ADS)
Zhang, Linna; Ding, Hongyan; Lin, Ling; Wang, Yimin; Guo, Xin
2018-01-01
Noncontact discriminating human blood is significantly crucial for import-export ports and inspection and quarantine departments. We had already demonstrated that visible diffuse reflectance spectroscopy combining PLS-DA method can successfully realize noncontact human blood discrimination. However, the circulated blood vessels may be produced with different materials. The use of various kinds of blood tubes may have a negative effect on the discrimination, based on ;M+N; theory (Li et al., 2016). In this research, we explored the impact of different material of blood vessels, such as glass tube and plastic tube, on the prediction ability of the discrimination model. Furthermore, we searched for the modification method to reduce the influence from the blood tubes. Our work indicated that generalized diffuse reflectance method can greatly improve the discrimination accuracy. This research can greatly facilitate the application of noncontact discrimination method based on visible and near-infrared diffuse reflectance spectroscopy.
An update on X-ray reflection gratings developed for future missions
NASA Astrophysics Data System (ADS)
Miles, Drew
2018-01-01
X-ray reflection gratings are a key technology being studied for future X-ray spectroscopy missions, including the Lynx X-ray mission under consideration for the 2020 Decadal Survey. We present an update on the status of X-ray reflection gratings being developed at Penn State University, including current fabrication techniques and mass-replication processes and the latest diffraction efficiency results and resolving power measurements. Individual off-plane X-ray reflection gratings have exceeded the current Lynx requirements for both effective area and resolving power. Finally, we discuss internal projects that will advance the technology readiness level of these gratings.
NASA Astrophysics Data System (ADS)
Moran, J.; Kelly, J.; Sams, R.; Newburn, M.; Kreuzer, H.; Alexander, M.
2011-12-01
Quick incorporation of IR spectroscopy based isotope measurements into cutting edge research in biogeochemical cycling attests to the advantages of a spectroscopy versus mass spectrometry method for making some 13C measurements. The simple principles of optical spectroscopy allow field portability and provide a more robust general platform for isotope measurements. We present results with a new capillary absorption spectrometer (CAS) with the capability of reducing the sample size required for high precision isotopic measurements to the picomolar level and potentially the sub-picomolar level. This work was motivated by the minute sample size requirements for laser ablation isotopic studies of carbon cycling in microbial communities but has potential to be a valuable tool in other areas of biological and geological research. The CAS instrument utilizes a capillary waveguide as a sample chamber for interrogating CO2 via near IR laser absorption spectroscopy. The capillary's small volume (~ 0.5 mL) combined with propagation and interaction of the laser mode with the entire sample reduces sample size requirements to a fraction of that accessible with commercially available IR absorption including those with multi-pass or ring-down cavity systems. Using a continuous quantum cascade laser system to probe nearly adjacent rovibrational transitions of different isotopologues of CO2 near 2307 cm-1 permits sample measurement at low analyte pressures (as low as 2 Torr) for further sensitivity improvement. A novel method to reduce cw-fringing noise in the hollow waveguide is presented, which allows weak absorbance features to be studied at the few ppm level after averaging 1,000 scans in 10 seconds. Detection limits down to the 20 picomoles have been observed, a concentration of approximately 400 ppm at 2 Torr in the waveguide with precision and accuracy at or better than 1 %. Improvements in detection and signal averaging electronics and laser power and mode quality are anticipated to reduce the required samples size to a 100-200 femtomoles of carbon. We report the application of the CAS system to a Laser Ablation-Catalytic-Combustion (LA-CC) micro-sampler system for selectively harvesting detailed sections of a solid surface for 13C analysis. This technique results in a three order of magnitude sensitivity improvement reported for our isotope measurement system compared to typical IRMS, providing new opportunities for making detailed investigations into wide ranges of microbial, physical, and chemical systems. The CAS is interfaced directly to the LA CC system currently operating at a 50 μm spatial resolution. We demonstrate that particulates produced by a Nd:YAG laser (λ=266nm) are isotopically homogenous with the parent material as measured by both IRMS and the CAS system. An improved laser ablation system operating at 193 nm with a spatial resolution of 2 microns or better is under development which will demonstrate the utility of the CAS system for sample sizes too low for IRMS. The improved sensitivities and optimized spatial targeting of such a system could interrogate targets as detailed as small cell clusters or intergrain organic deposits and could enhance ability to track biogeochemical carbon cycling.
Color and surface chemistry changes of extracted wood flour after heating at 120 °C
Yao Chen; Mandla A. Tshabalala; Jianmin Gao; Nicole M. Stark
2013-01-01
To investigate the effect of heat on color and surface chemistry of wood flour (WF), unextracted, extracted and delignified samples of commercial WF were heated at 120 °C for 24 h and analyzed by colorimetry, diffuse reflectance visible (DRV), attenuated total reflectance Fourier transform infrared (ATR-FTIR) and Fourier transform Raman (FT-Raman) spectroscopies....
Vibrational Spectroscopy of Laser Cooled CaH
2015-10-28
about 1 mW 369 nm laser with a bandpass filter ( Semrock 395/20 nm) that reflects the 21 399 nm laser and transmits the 369 nm laser, which are sent along...and the back mirror is a flat broadband 67 ( Semrock MaxMirror) mirror that has over 99% reflectivity over a wide range as shown in Fig. 28. The lasers
Thomas L. Eberhardt
2009-01-01
The outer bark (rhytidome) of the southern yellow pines is a complex structure comprised of alternating layers of obliterated phloem and periderm tissues, with the latter comprised of three layers, those being phellem, phellogen, and phelloderm. An attenuated total reflectance (ATR) sampling accessory, coupled with a Fourier transform infrared (FTIR) spectrometer,...
Sensing of moisture content in in-shell peanuts by NIR (Near Infra Red) reflectance spectroscopy
USDA-ARS?s Scientific Manuscript database
It was found earlier that moisture content (MC) of intact kernels of grain and nuts could be determined by Near Infra Red (NIR) reflectance spectrometry. However, if the MC values can be determined while the nuts are in their shells, it would save lot of labor and money spent in shelling and cleanin...
Alfano, Robert R.; Yang, Yuanlong
2003-09-02
Method and apparatus for examining biological materials using diffuse reflectance spectroscopy and the Kubelka-Munk function. In one aspect, the method is used to determine whether a tissue sample is cancerous or not and comprises the steps of (a) measuring the diffuse reflectance from the tissue sample at a first wavelength and at a second wavelength, wherein the first wavelength is a wavelength selected from the group consisting of 255-265 nm and wherein the second wavelength is a wavelength selected from the group consisting of 275-285 nm; (b) using the Kubelka-Munk function to transform the diffuse reflectance measurement obtained at the first and second wavelengths; and (c) comparing a ratio or a difference of the transformed Kubelka-Munk measurements at the first and second wavelengths to appropriate standards determine whether or not the tissue sample is cancerous. One can use the spectral profile of KMF between 250 nm to 300 nm to determine whether or not the tissue sample is cancerous or precancerous. According to the value at the first and second wavelengths determine whether or not the malignant tissue is invasive or mixed invasive and in situ or carcinoma in situ.
Measuring joint cartilage thickness using reflectance spectroscopy non-invasively and in real-time
NASA Astrophysics Data System (ADS)
Canpolat, Murat; Denkceken, Tuba; Karagol, Cosar; Aydin, Ahmet T.
2011-03-01
Joint cartilage thickness has been estimated using spatially resolved steady-state reflectance spectroscopy noninvasively and in-real time. The system consists of a miniature UV-VIS spectrometer, a halogen tungsten light source, and an optical fiber probe with six 400 um diameter fibers. The first fiber was used to deliver the light to the cartilage and the other five were used to detect back-reflected diffused light. Distances from the detector fibers to the source fiber were 0.8 mm, 1.6 mm, 2.4 mm, 3.2 mm and 4 mm. Spectra of back-reflected diffused light were taken on 40 bovine patella cartilages. The samples were grouped into four; the first group was the control group with undamaged cartilages, in the 2nd, 3rd and 4th groups cartilage thickness was reduced approximately 25%, 50% and 100%, respectively. A correlation between cartilage thicknesses and hemoglobin absorption of light in the wavelength range of 500 nm- 600 nm for source-detector pairs was found. The proposed system with an optical fiber probe less than 4 mm in diameter has the potential for cartilage thickness assessment through an arthroscopy channel in real-time without damaging the cartilage.
Identification of natural red and purple dyes on textiles by Fiber-optics Reflectance Spectroscopy
NASA Astrophysics Data System (ADS)
Maynez-Rojas, M. A.; Casanova-González, E.; Ruvalcaba-Sil, J. L.
2017-05-01
Understanding dye chemistry and dye processes is an important issue for studies of cultural heritage collections and science conservation. Fiber Optics Reflectance Spectroscopy (FORS) is a powerful technique, which allows preliminary dye identification, causing no damage or mechanical stress on the artworks subjected to analysis. Some information related to specific light scattering and absorption can be obtained in the UV-visible and infrared range (300-1400 nm) and it is possible to discriminate the kind of support fiber in the near infrared region (1000-2500 nm). The main spectral features of natural dye fibers samples, such as reflection maxima, inflection points and reflection minima, can be used in the differentiation of various red natural dyes. In this work, a set of dyed references were manufactured following Mexican recipes with red dyes (cochineal and brazilwood) in order to determine the characteristic FORS spectral features of fresh and aged dyed fibers for their identification in historical pieces. Based on these results, twenty-nine indigenous textiles belonging to the National Commission for the Development of Indigenous People of Mexico were studied. Cochineal and brazilwood were successfully identified by FORS in several pieces, as well as the mixture of cochineal and indigo for purple color.
NASA Astrophysics Data System (ADS)
Tao, Xuemei; He, Yong
2006-09-01
The internal quality of tomato such as acidity and sugar content is important to its taste thus influences the market. The objective of this paper was to demonstrate the feasibility of using a near-infrared spectroscopy (NIRS) to investigate the relationship between sugar content and acidity of tomato and absorption spectra. The N1RS reflectance of nondestructive tomatoes was measured with a Visible/NJR spectrophotometer in 325-1075 nm range. The sugar content and acidity of tomato were obtained with a handhold sugar content meter and a PH meter. The reflectance data set was recorded and analyzed with some mathematic methods. The PLS (Partial least squares) calibration method was developed for converting the NIRS reflectance of tomato into the data which determined the acidity value. BP (Back propagation) neural network was used to set up the relationship between the NIRS reflectance of tomato and sugar content. The acidity values were detected with an accuracy of 9O% and the sugar contents determined by the BP network were also very close to the measurements (coefficient of correlation r2=0.8764). NW spectra analysis would be very useful in the nondestructive internal quality inspecting of tomato.
Biomimetic graphene sensors: functionalizing graphene with peptides
NASA Astrophysics Data System (ADS)
Ishigami, Masa; Nyon Kim, Sang; Naik, Rajesh; Tatulian, Suren A.; Katoch, Jyoti
2012-02-01
Non-covalent biomimetic functionalization of graphene using peptides is one of more promising methods for producing novel sensors with high sensitivity and selectivity. Here we combine atomic force microscopy, Raman spectroscopy, and attenuated total reflection Fourier transform infrared spectroscopy to investigate peptide binding to graphene and graphite. We choose to study a dodecamer peptide identified with phage display to possess affinities for graphite and we find that the peptide forms a complex mesh-like structure upon adsorption on graphene. Moreover, optical spectroscopy reveals that the peptide binds non-covalently to graphene and possesses an optical signature of an ?-helical conformation on graphene.
Pfeifer, Marcel; Ruf, Alexander; Fischer, Peer
2013-11-04
We record vibrational spectra with two indirect schemes that depend on the real part of the index of refraction: mid-infrared refractometry and photothermal spectroscopy. In the former, a quantum cascade laser (QCL) spot is imaged to determine the angles of total internal reflection, which yields the absorption line via a beam profile analysis. In the photothermal measurements, a tunable QCL excites vibrational resonances of a molecular monolayer, which heats the surrounding medium and changes its refractive index. This is observed with a probe laser in the visible. Sub-monolayer sensitivities are demonstrated.
Spectroscopy analysis of phenolic and sugar patterns in a food grade chestnut tannin.
Ricci, A; Lagel, M-C; Parpinello, G P; Pizzi, A; Kilmartin, P A; Versari, A
2016-07-15
Tannin of chestnut (Castanea sativa Mill.) wood, commonly used in winemaking was characterised with a spectroscopy qualitative approach that revealed its phenolic composition: several vibrational diagnostic bands assigned using the Attenuated Total Reflectance-Infrared Spectroscopy, and fragmentation patterns obtained using the Laser-Desorption-Ionization Time-of-Flight technique evidenced polygalloylglucose, e.g. castalagin/vescalagin-like structures as the most representative molecules, together with sugar moieties. The implication of these findings on winemaking application and the potential influence of the chemical structure on the sensory properties of wine are discussed. Copyright © 2016 Elsevier Ltd. All rights reserved.
Krueger, Mark; Berg, Shannon; Stone, D'Arcy; Strelcov, Evgheni; Dikin, Dmitriy A; Kim, Jaemyung; Cote, Laura J; Huang, Jiaxing; Kolmakov, Andrei
2011-12-27
Graphene oxide sheets dispersed in water and many other solvents can spontaneously assemble into a surface film covering an evaporating droplet due to their amphiphilicity. Thus, graphene oxide membranes with controllable thickness suspended over an orifice have been directly fabricated using a simple drop-cast approach. Mechanical properties and electron transparency tests of these membranes show their use as electron transparent, but molecularly impenetrable, windows for environmental electron microscopy in liquids and dense gaseous media. The foreseeable, broader application of this drop-cast window methodology is the creation of access spots for electron probes to study isolated microsamples in their natural, undisrupted state within the interior of prefabricated devices (such as microfluidic chips or sealed containers of biological, chemically reactive, toxic, or forensic materials).
Homogamy and Intermarriage of Japanese and Japanese Americans With Whites Surrounding World War II.
Ono, Hiromi; Berg, Justin
2010-10-01
Although some sociologists have suggested that Japanese Americans quickly assimilated into mainstream America, scholars of Japanese America have highlighted the heightened exclusion that the group experienced. This study tracked historical shifts in the exclusion level of Japanese and Japanese Americans in the United States surrounding World War II with homogamy and intermarriage with Whites for the prewar (1930-1940) and resettlement (1946-1966) marriage cohorts. The authors applied log-linear models to census microsamples (N = 1,590,416) to estimate the odds ratios of homogamy versus intermarriage. The unadjusted odds ratios of Japanese Americans declined between cohorts and appeared to be consistent with the assimilation hypothesis. Once compositional influences and educational pairing patterns were adjusted, however, the odds ratios increased and supported the heightened exclusion hypothesis.
Americium alloys with gold and copper
NASA Astrophysics Data System (ADS)
Radchenko, V. M.; Ryabinin, M. A.; Chernakova, T. A.; Tomilin, S. V.
2010-03-01
Presented are results of the production and X-ray examination of micro-samples of americium-241 compounds with gold and copper produced by high-temperature condensation of metal americium vapor onto corresponding substrates. No mutual solubility of the investigated system components was revealed at room temperature. The following three intermetallic compounds were revealed in the Am-Au system: Au6Am with tetragonal lattice of the Au6Sm structural type, AuAm with orthorhombic lattice of the CuCe structural type and AuAm with cubic lattice. The Am-Cu system showed the intermetallic compound Cu5Am (Cu7Am) with a hexagonal lattice of the Cu5Ca(Cu7Tb) structure type. An effect of the 241Am nuclide alpha-activity on the crystal structure of the produced intermetallide was studied.
Hybertson, Brooks M.
2010-01-01
The solubility of the vitamin E-related compound α-tocopheryl succinate in supercritical carbon dioxide was measured at pressures ranging from (15.0 to 30.0) MPa and temperatures of (40 and 50) °C using a simple microsampling type apparatus with a 100.5 μL sample loop to remove aliquots and collect them in ethanol for off line analysis. α-Tocopheryl succinate concentrations in the collected samples were measured using HPLC-MS/MS analysis. The solubility of α-tocopheryl succinate in supercritical carbon dioxide ranged from mole fractions of 0.28 × 10−5 at 15.0 MPa and 50 °C to 2.56 × 10−5 at 30.0 MPa and 50 °C. PMID:20953319
Mori, Yoshifumi; Chung, Ung-Il; Tanaka, Sakae; Saito, Taku
2014-01-01
Superficial zone (SFZ) cells, which are morphologically and functionally distinct from chondrocytes in deeper zones, play important roles in the maintenance of articular cartilage. Here, we established an easy and reliable method for performance of laser microdissection (LMD) on cryosections of mature rat articular cartilage using an adhesive membrane. We further examined gene expression profiles in the SFZ and the deeper zones of articular cartilage by performing RNA sequencing (RNA-seq). We validated sample collection methods, RNA amplification and the RNA-seq data using real-time RT-PCR. The combined data provide comprehensive information regarding genes specifically expressed in the SFZ or deeper zones, as well as a useful protocol for expression analysis of microsamples of hard tissues.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Couture, John J.; Singh, Aditya; Rubert-Nason, Kennedy F.
Spectroscopy has recently emerged as an effective method to accurately characterize leaf biochemistry in living tissue through the application of chemometric approaches to foliar optical data, but this approach has not been widely used for plant secondary metabolites. Here in this paper, we examine the ability of reflectance spectroscopy to quantify specific phenolic compounds in trembling aspen (Populus tremuloides) and paper birch (Betula papyrifera) that play influential roles in ecosystem functioning related to trophic-level interactions and nutrient cycling.
NASA Astrophysics Data System (ADS)
Cicchi, Riccardo; Anand, Suresh; Fantechi, Riccardo; Giordano, Flavio; Gacci, Mauro; Conti, Valerio; Nesi, Gabriella; Buccoliero, Anna Maria; Carini, Marco; Guerrini, Renzo; Pavone, Francesco Saverio
2017-07-01
An optical fiber probe for multimodal spectroscopy was designed, developed and used for tissue diagnostics. The probe, based on a fiber bundle with optical fibers of various size and properties, allows performing spectroscopic measurements with different techniques, including fluorescence, Raman, and diffuse reflectance, using the same probe. Two visible laser diodes were used for fluorescence spectroscopy, a laser diode emitting in the NIR was used for Raman spectroscopy, and a fiber-coupled halogen lamp for diffuse reflectance. The developed probe was successfully employed for diagnostic purposes on various tissues, including brain and bladder. In particular, the device allowed discriminating healthy tissue from both tumor and dysplastic tissue as well as to perform tumor grading. The diagnostic capabilities of the method, determined using a cross-validation method with a leave-one-out approach, demonstrated high sensitivity and specificity for all the examined samples, as well as a good agreement with histopathological examination performed on the same samples. The obtained results demonstrated that the multimodal approach is crucial for improving diagnostic capabilities with respect to what can be obtained from individual techniques. The experimental setup presented here can improve diagnostic capabilities on a broad range of tissues and has the potential of being used clinically for guiding surgical resection in the near future.
NASA Astrophysics Data System (ADS)
Spliethoff, Jarich W.; de Boer, Lisanne L.; Meier, Mark A. J.; Prevoo, Warner; de Jong, Jeroen; Kuhlmann, Koert; Bydlon, Torre M.; Sterenborg, Henricus J. C. M.; Hendriks, Benno H. W.; Ruers, Theo J. M.
2016-09-01
There is a strong need to develop clinical instruments that can perform rapid tissue assessment at the tip of smart clinical instruments for a variety of oncological applications. This study presents the first in vivo real-time tissue characterization during 24 liver biopsy procedures using diffuse reflectance (DR) spectroscopy at the tip of a core biopsy needle with integrated optical fibers. DR measurements were performed along each needle path, followed by biopsy of the target lesion using the same needle. Interventional imaging was coregistered with the DR spectra. Pathology results were compared with the DR spectroscopy data at the final measurement position. Bile was the primary discriminator between normal liver tissue and tumor tissue. Relative differences in bile content matched with the tissue diagnosis based on histopathological analysis in all 24 clinical cases. Continuous DR measurements during needle insertion in three patients showed that the method can also be applied for biopsy guidance or tumor recognition during surgery. This study provides an important validation step for DR spectroscopy-based tissue characterization in the liver. Given the feasibility of the outlined approach, it is also conceivable to make integrated fiber-optic tools for other clinical procedures that rely on accurate instrument positioning.
Brittain, Harry G
2016-01-01
Through the combined use of infrared (IR) absorption spectroscopy and attenuated total reflectance (ATR) sampling, the composition of inks used to print the many different types of one-cent Benjamin Franklin stamps of the 19th century has been established. This information permits a historical evaluation of the formulations used at various times, and also facilitates the differentiation of the various stamps from each other. In two instances, the ink composition permits the unambiguous identification of stamps whose appearance is identical, and which (until now) have only been differentiated through estimates of the degree of hardness or softness of the stamp paper, or through the presence or absence of a watermark in the paper. In these instances, the use of ATR Fourier transform infrared spectroscopy (FT-IR) spectroscopy effectively renders irrelevant two 100-year-old practices of stamp identification. Furthermore, since the use of ATR sampling makes it possible to obtain the spectrum of a stamp still attached to its cover, it is no longer necessary to identify these blue Franklin stamps using their cancellation dates. © The Author(s) 2015.
The Use of UV-Visible Reflectance Spectroscopy as an Objective Tool to Evaluate Pearl Quality
Agatonovic-Kustrin, Snezana; Morton, David W.
2012-01-01
Assessing the quality of pearls involves the use of various tools and methods, which are mainly visual and often quite subjective. Pearls are normally classified by origin and are then graded by luster, nacre thickness, surface quality, size, color and shape. The aim of this study was to investigate the capacity of Artificial Neural Networks (ANNs) to classify and estimate the quality of 27 different pearls from their UV-Visible spectra. Due to the opaque nature of pearls, spectroscopy measurements were performed using the Diffuse Reflectance UV-Visible spectroscopy technique. The spectra were acquired at two different locations on each pearl sample in order to assess surface homogeneity. The spectral data (inputs) were smoothed to reduce the noise, fed into ANNs and correlated to the pearl’s quality/grading criteria (outputs). The developed ANNs were successful in predicting pearl type, mollusk growing species, possible luster and color enhancing, donor condition/type, recipient/host color, donor color, pearl luster, pearl color, origin. The results of this study shows that the developed UV-Vis spectroscopy-ANN method could be used as a more objective method of assessing pearl quality (grading) and may become a valuable tool for the pearl grading industry. PMID:22851919
Esmonde-White, Karen A; Cuellar, Maryann; Uerpmann, Carsten; Lenain, Bruno; Lewis, Ian R
2017-01-01
Adoption of Quality by Design (QbD) principles, regulatory support of QbD, process analytical technology (PAT), and continuous manufacturing are major factors effecting new approaches to pharmaceutical manufacturing and bioprocessing. In this review, we highlight new technology developments, data analysis models, and applications of Raman spectroscopy, which have expanded the scope of Raman spectroscopy as a process analytical technology. Emerging technologies such as transmission and enhanced reflection Raman, and new approaches to using available technologies, expand the scope of Raman spectroscopy in pharmaceutical manufacturing, and now Raman spectroscopy is successfully integrated into real-time release testing, continuous manufacturing, and statistical process control. Since the last major review of Raman as a pharmaceutical PAT in 2010, many new Raman applications in bioprocessing have emerged. Exciting reports of in situ Raman spectroscopy in bioprocesses complement a growing scientific field of biological and biomedical Raman spectroscopy. Raman spectroscopy has made a positive impact as a process analytical and control tool for pharmaceutical manufacturing and bioprocessing, with demonstrated scientific and financial benefits throughout a product's lifecycle.
NASA Astrophysics Data System (ADS)
Kitazaki, Tomoya; Mori, Keita; Yamamoto, Naoyuki; Wang, Congtao; Kawashima, Natsumi; Ishimaru, Ichiro
2017-07-01
We proposed the extremely compact beans-size snap-shot mid-infrared spectroscopy that will be able to be built in smartphones. And also the easy preparation method of thin-film samples generated by ultrasonic standing wave is proposed. Mid-infrared spectroscopy is able to identify material components and estimate component concentrations quantitatively from absorption spectra. But conventional spectral instruments were very large-size and too expensive to incorporate into daily life. And preparations of thin-film sample were very troublesome task. Because water absorption in mid-infrared lights is very strong, moisture-containing-sample thickness should be less than 100[μm]. Thus, midinfrared spectroscopy has been utilized only by analytical experts in their laboratories. Because ultrasonic standing wave is compressional wave, we can generate periodical refractive-index distributions inside of samples. A high refractiveindex plane is correspond to a reflection boundary. When we use a several MHz ultrasonic transducer, the distance between sample surface and generated first node become to be several ten μm. Thus, the double path of this distance is correspond to sample thickness. By combining these two proposed methods, as for liquid samples, urinary albumin and glucose concentrations will be able to be measured inside of toilet. And as for solid samples, by attaching these apparatus to earlobes, the enhancement of reflection lights from near skin surface will create a new path to realize the non-invasive blood glucose sensor. Using the small ultrasonic-transducer whose diameter was 10[mm] and applied voltage 8[V], we detected the internal reflection lights from colored water as liquid sample and acrylic board as solid sample.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meemken, Fabian; Müller, Philipp; Hungerbühler, Konrad
Design and performance of a reactor set-up for attenuated total reflection infrared (ATR-IR) spectroscopy suitable for simultaneous reaction monitoring of bulk liquid and catalytic solid-liquid-gas interfaces under working conditions are presented. As advancement of in situ spectroscopy an operando methodology for gas-liquid-solid reaction monitoring was developed that simultaneously combines catalytic activity and molecular level detection at the catalytically active site of the same sample. Semi-batch reactor conditions are achieved with the analytical set-up by implementing the ATR-IR flow-through cell in a recycle reactor system and integrating a specifically designed gas feeding system coupled with a bubble trap. By the usemore » of only one spectrometer the design of the new ATR-IR reactor cell allows for simultaneous detection of the bulk liquid and the catalytic interface during the working reaction. Holding two internal reflection elements (IRE) the sample compartments of the horizontally movable cell are consecutively flushed with reaction solution and pneumatically actuated, rapid switching of the cell (<1 s) enables to quasi simultaneously follow the heterogeneously catalysed reaction at the catalytic interface on a catalyst-coated IRE and in the bulk liquid on a blank IRE. For a complex heterogeneous reaction, the asymmetric hydrogenation of 2,2,2-trifluoroacetophenone on chirally modified Pt catalyst the elucidation of catalytic activity/enantioselectivity coupled with simultaneous monitoring of the catalytic solid-liquid-gas interface is shown. Both catalytic activity and enantioselectivity are strongly dependent on the experimental conditions. The opportunity to gain improved understanding by coupling measurements of catalytic performance and spectroscopic detection is presented. In addition, the applicability of modulation excitation spectroscopy and phase-sensitive detection are demonstrated.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, T.P.
Sensors for the determination of pH have been developed which are based on the immobilization of direct dyes at hydrolyzed cellulosic films. The performance and structural characteristics of the sensors were investigated by a variety of spectroscopic methods, and applications for remote sensing were developed. Films of cellulose acetate were base hydrolyzed in 0.07 M KOH to yield a porous support structure. The structural changes resulting from the hydrolysis on cellulose acetate were probed with infrared internal reflectance spectroscopy. The progress of the hydrolysis reaction was monitored by the changes in vibrational modes of the acetyl group, and other spectralmore » changes indicated changes in film thickness as a result of solvent incorporation. Direct dyes, including Congo Red and C. I. Direct Blue 8, were then immobilized at these porous cellulosic films. The optical response characteristics of the Congo Red pH sensor were characterized, including the UV-visible absorption spectra as a function of pH, the response time as a function of ionic strength and ionic size of electrolyte, the long-term stability of the sensor, the effects of metal-ion interference, and the concentration of Congo Red in the polymer film. The structural characteristics of the sensor were investigated by internal reflectance spectroscopy and resonance-enhanced Raman spectroscopy, and the protonation sites were identified as the two azo groups of Congo Red. Infrared internal reflection spectra of immobilized Congo Red led to the development of a sensor for pH based on infrared spectroscopy. Finally, a two-wavelength fiber-optic photometer, which is based on solid-state sources and detectors, and a fiber-optic photometer, which is based on solid-state sources and detectors, and a fiber-optic probe were developed for pH determinations using Congo Red and C. I. Direct Blue 8 pH sensors.« less
Askenazi, David J; Moore, John F; Fineberg, Naomi; Koralkar, Rajesh; Clevenger, Stephanie; Sharer, Jon Daniel
2014-09-01
Measurement of serum creatinine (SCr) and urine creatinine (UCr) is regularly used in clinical and research settings. For small animal experiments and for studies in which sample collection is spare (i.e. neonatal cohorts), measuring SCr and UCr using tiny amounts of sample (as low as 10 mcl) would maximize exploration and minimize iatrogenic blood loss. We performed an evaluation in six healthy adults to determine differences between SCr and UCr values in different methodologies and storage environments and time. Study was conducted using 20 mcl of sample. Analyses were done using two-way repeated measures of ANOVA. Scr values showed no significant differences between LC/MS vs. Jaffe. However, the SCr using LC/MS method was lowest when measured immediately compared to other time points (F = 7.2; P< 0.001). Similarly, Jaffe measurements showed changes in the mean differences over time; however, these were not significant. UCr values were consistently higher using LC/MS than Jaffe (F = 19; P< 0.01), and UCr changed over time (F = 8.7; P < 0.02). In addition, the interaction term for method and time was also significant (F = 5.8; P < 0.04) which reflects the stability of the Jaffe measurements over time whereas the LC/MS measurements declined; especially after being frozen for 1 year (P < 0.001). UCr measured by Jaffe is lower than samples measured by LC/MS. UCr measurements by LC/MS vary more over time, mostly due to the sample measured after 1 year; therefore, storage of urine for more than 90 days measured by LC/MS may provide altered results. © 2014 Wiley Periodicals, Inc.
2015-01-01
This work describes the method of a selective hydride generation-cryotrapping (HG-CT) coupled to an extremely sensitive but simple in-house assembled and designed atomic fluorescence spectrometry (AFS) instrument for determination of toxicologically important As species. Here, an advanced flame-in-gas-shield atomizer (FIGS) was interfaced to HG-CT and its performance was compared to a standard miniature diffusion flame (MDF) atomizer. A significant improvement both in sensitivity and baseline noise was found that was reflected in improved (4 times) limits of detection (LODs). The yielded LODs with the FIGS atomizer were 0.44, 0.74, 0.15, 0.17 and 0.67 ng L–1 for arsenite, total inorganic, mono-, dimethylated As and trimethylarsine oxide, respectively. Moreover, the sensitivities with FIGS and MDF were equal for all As species, allowing for the possibility of single species standardization with arsenate standard for accurate quantification of all other As species. The accuracy of HG-CT-AFS with FIGS was verified by speciation analysis in two samples of bottled drinking water and certified reference materials, NRC CASS-5 (nearshore seawater) and SLRS-5 (river water) that contain traces of methylated As species. As speciation was in agreement with results previously reported and sums of all quantified species corresponded with the certified total As. The feasibility of HG-CT-AFS with FIGS was also demonstrated by the speciation analysis in microsamples of exfoliated bladder epithelial cells isolated from human urine. The results for the sums of trivalent and pentavalent As species corresponded well with the reference results obtained by HG-CT-ICPMS (inductively coupled plasma mass spectrometry). PMID:25300934
Svarcová, Silvie; Kocí, Eva; Bezdicka, Petr; Hradil, David; Hradilová, Janka
2010-09-01
The uniqueness and limited amounts of forensic samples and samples from objects of cultural heritage together with the complexity of their composition requires the application of a wide range of micro-analytical methods, which are non-destructive to the samples, because these must be preserved for potential late revision. Laboratory powder X-ray micro-diffraction (micro-XRD) is a very effective non-destructive technique for direct phase analysis of samples smaller than 1 mm containing crystal constituents. It compliments optical and electron microscopy with elemental micro-analysis, especially in cases of complicated mixtures containing phases with similar chemical composition. However, modification of X-ray diffraction to the micro-scale together with its application for very heterogeneous real samples leads to deviations from the standard procedure. Knowledge of both the limits and the phenomena which can arise during the analysis is crucial for the meaningful and proper application of the method. We evaluated basic limits of micro-XRD equipped with a mono-capillary with an exit diameter of 0.1 mm, for example the size of irradiated area, appropriate grain size, and detection limits allowing identification of given phases. We tested the reliability and accuracy of quantitative phase analysis based on micro-XRD data in comparison with conventional XRD (reflection and transmission), carrying out experiments with two-phase model mixtures simulating historic colour layers. Furthermore, we demonstrate the wide use of micro-XRD for investigation of various types of micro-samples (contact traces, powder traps, colour layers) and we show how to enhance data quality by proper choice of experiment geometry and conditions.
Musil, Stanislav; Matoušek, Tomáš; Currier, Jenna M; Stýblo, Miroslav; Dědina, Jiří
2014-10-21
This work describes the method of a selective hydride generation-cryotrapping (HG-CT) coupled to an extremely sensitive but simple in-house assembled and designed atomic fluorescence spectrometry (AFS) instrument for determination of toxicologically important As species. Here, an advanced flame-in-gas-shield atomizer (FIGS) was interfaced to HG-CT and its performance was compared to a standard miniature diffusion flame (MDF) atomizer. A significant improvement both in sensitivity and baseline noise was found that was reflected in improved (4 times) limits of detection (LODs). The yielded LODs with the FIGS atomizer were 0.44, 0.74, 0.15, 0.17 and 0.67 ng L(-1) for arsenite, total inorganic, mono-, dimethylated As and trimethylarsine oxide, respectively. Moreover, the sensitivities with FIGS and MDF were equal for all As species, allowing for the possibility of single species standardization with arsenate standard for accurate quantification of all other As species. The accuracy of HG-CT-AFS with FIGS was verified by speciation analysis in two samples of bottled drinking water and certified reference materials, NRC CASS-5 (nearshore seawater) and SLRS-5 (river water) that contain traces of methylated As species. As speciation was in agreement with results previously reported and sums of all quantified species corresponded with the certified total As. The feasibility of HG-CT-AFS with FIGS was also demonstrated by the speciation analysis in microsamples of exfoliated bladder epithelial cells isolated from human urine. The results for the sums of trivalent and pentavalent As species corresponded well with the reference results obtained by HG-CT-ICPMS (inductively coupled plasma mass spectrometry).
NASA Astrophysics Data System (ADS)
Oh, Sanghoon; Fernald, Bradley; Bhatia, Sanjiv; Ragheb, John; Sandberg, David; Johnson, Mahlon; Lin, Wei-Chiang
2009-05-01
This research investigated the feasibility of using time-dependent diffuse reflectance spectroscopy to differentiate pediatric epileptic brain tissue from normal brain tissue. The optical spectroscopic technique monitored the dynamic optical properties of the cerebral cortex that are associated with its physiological, morphological, and compositional characteristics. Due to the transient irregular epileptic discharge activity within the epileptic brain tissue it was hypothesized that the lesion would express abnormal dynamic optical behavior that would alter normal dynamic behavior. Thirteen pediatric epilepsy patients and seven pediatric brain tumor patients (normal controls) were recruited for this clinical study. Dynamic optical properties were obtained from the cortical surface intraoperatively using a timedependent diffuse reflectance spectroscopy system. This system consisted of a fiber-optic probe, a tungsten-halogen light source, and a spectrophotometer. It acquired diffuse reflectance spectra with a spectral range of 204 nm to 932 nm at a rate of 33 spectra per second for approximately 12 seconds. Biopsy samples were taken from electrophysiologically abnormal cortex and evaluated by a neuropathologist, which served as a gold standard for lesion classification. For data analysis, spectral intensity changes of diffuse reflectance in the time domain at two different wavelengths from each investigated site were compared. Negative correlation segment, defined by the periods where the intensity changes at the two wavelengths were opposite in their slope polarity, were extracted. The total duration of negative correlation, referred to as the "negative correlation time index", was calculated by integrating the negative correlation segments. The negative correlation time indices from all investigated sites were sub-grouped according to the corresponding histological classifications. The difference between the mean indices of two subgroups was evaluated by standard t-test. These comparison and calculation procedures were carried out for all possible wavelength combinations between 400 nm and 800 nm with 2 nm increments. The positive group consisted of seven pathologically abnormal test sites, and the negative group consisted of 13 normal test sites from non-epileptic tumor patients. A standard t-test showed significant difference between negative correlation time indices from the two groups at the wavelength combinations of 700-760 nm versus 550-580 nm. An empirical discrimination algorithm based on the negative correlation time indices in this range produced 100% sensitivity and 85% specificity. Based on these results time-dependent diffuse reflectance spectroscopy with optimized data analysis methods differentiates epileptic brain tissue from normal brain tissue adequately, therefore can be utilized for surgical guidance, and may enhance the surgical outcome of pediatric epilepsy surgery.
da Silva, Fabiana E B; Flores, Érico M M; Parisotto, Graciele; Müller, Edson I; Ferrão, Marco F
2016-03-01
An alternative method for the quantification of sulphametoxazole (SMZ) and trimethoprim (TMP) using diffuse reflectance infrared Fourier-transform spectroscopy (DRIFTS) and partial least square regression (PLS) was developed. Interval Partial Least Square (iPLS) and Synergy Partial Least Square (siPLS) were applied to select a spectral range that provided the lowest prediction error in comparison to the full-spectrum model. Fifteen commercial tablet formulations and forty-nine synthetic samples were used. The ranges of concentration considered were 400 to 900 mg g-1SMZ and 80 to 240 mg g-1 TMP. Spectral data were recorded between 600 and 4000 cm-1 with a 4 cm-1 resolution by Diffuse Reflectance Infrared Fourier Transform Spectroscopy (DRIFTS). The proposed procedure was compared to high performance liquid chromatography (HPLC). The results obtained from the root mean square error of prediction (RMSEP), during the validation of the models for samples of sulphamethoxazole (SMZ) and trimethoprim (TMP) using siPLS, demonstrate that this approach is a valid technique for use in quantitative analysis of pharmaceutical formulations. The selected interval algorithm allowed building regression models with minor errors when compared to the full spectrum PLS model. A RMSEP of 13.03 mg g-1for SMZ and 4.88 mg g-1 for TMP was obtained after the selection the best spectral regions by siPLS.
Assessing human skin with diffuse reflectance spectroscopy and colorimetry
NASA Astrophysics Data System (ADS)
Seo, InSeok; Liu, Yang; Bargo, Paulo R.; Kollias, Nikiforos
2012-02-01
Colorimetry has been used as an objective measure of perceived skin color by human eye to document and score physiological responses of the skin from external insults. CIE color space values (L*, a* and b*) are the most commonly used parameters to correlate visually perceived color attributes such as L* for pigment, a* for erythema, and b* for sallowness of the skin. In this study, we investigated the relation of Lab color scale to the amount of major skin chromophores (oxy-, deoxyhemoglobin and melanin) calculated from diffuse reflectance spectroscopy. Thirty two healthy human subjects with ages from 20 to 70 years old, skin types I-VI, were recruited for the study. DRS and colorimetry measurements were taken from the left and right cheeks, and on the right upper inner arm. The melanin content calculated from 630-700 nm range of DRS measurements was shown to correlate with the lightness of skin (L*) for most skin types. For subjects with medium-to-light complexion, melanin measured at the blue part spectrum and hemoglobin interfered on the relation of lightness of the skin color to the melanin content. The sallowness of the skin that is quantified by the melanin contribution at the blue part spectrum of DRS was found to be related to b* scale. This study demonstrates the importance of documenting skin color by assessing individual skin chromophores with diffuse reflectance spectroscopy, in comparison to colorimetry assessment.
Rajic, S.; Egert, C.M.; Kahl, W.K.; Snyder, W.B. Jr.; Evans, B.M. III; Marlar, T.A.; Cunningham, J.P.
1998-05-19
A monolithic spectrometer is disclosed for use in spectroscopy. The spectrometer is a single body of translucent material with positioned surfaces for the transmission, reflection and spectral analysis of light rays. 6 figs.
Optical remote sensing of asteroid surfaces from spacecraft
NASA Technical Reports Server (NTRS)
Mccord, T. B.
1978-01-01
Reflectance spectroscopy and multispectral mapping are the techniques likely to be most useful for determining asteroid surfaces. Several other techniques should be considered for providing complementary information.
Synthesis and Characterization of Silicon Nanowires by Electroless Etching
NASA Astrophysics Data System (ADS)
Bhujel, Rabina; Rizal, Umesh; Agarwal, Amit; Swain, Bhabani S.; Swain, Bibhu P.
2018-02-01
Silicon nanowires (SiNWs) were synthesized by two-step electroless etching of p-type Si (100) wafer and characterized by field emission scanning electron microscopy, UV-Vis spectroscopy, x-ray photoelectron spectroscopy, Fourier transform infrared spectroscopy and Raman spectroscopy. The vibrational signature at 1108 and 2087 cm-1 confirmed SiNWs were passivated by both oxygen and hydrogen atoms. Raman peak at 517 cm-1 indicated crystalline SiNWs with tailing toward redshift due to Fano effect. The Si(2p) and Si(2s) core orbital spectra of SiNWs were found at 99.8 and 150.5 eV, respectively. Moreover, the reflection of SiNWs is minimized to 1 to 5% in the 650-nm wavelength.
Brown, J Quincy; Vishwanath, Karthik; Palmer, Gregory M; Ramanujam, Nirmala
2009-02-01
Methods of optical spectroscopy that provide quantitative, physically or physiologically meaningful measures of tissue properties are an attractive tool for the study, diagnosis, prognosis, and treatment of various cancers. Recent development of methodologies to convert measured reflectance and fluorescence spectra from tissue to cancer-relevant parameters such as vascular volume, oxygenation, extracellular matrix extent, metabolic redox states, and cellular proliferation have significantly advanced the field of tissue optical spectroscopy. The number of publications reporting quantitative tissue spectroscopy results in the UV-visible wavelength range has increased sharply in the past three years, and includes new and emerging studies that correlate optically measured parameters with independent measures such as immunohistochemistry, which should aid in increased clinical acceptance of these technologies.
Monte Carlo model of light transport in multi-layered tubular organs
NASA Astrophysics Data System (ADS)
Zhang, Yunyao; Zhu, Jingping; Zhang, Ning
2017-02-01
We present a Monte Carlo static light migration model (Endo-MCML) to simulate endoscopic optical spectroscopy for tubular organs such as esophagus and colon. The model employs multi-layered hollow cylinder which emitting and receiving light both from the inner boundary to meet the conditions of endoscopy. Inhomogeneous sphere can be added in tissue layers to model cancer or other abnormal changes. The 3D light distribution and exit angle would be recorded as results. The accuracy of the model has been verified by Multi-layered Monte Carlo(MCML) method and NIRFAST. This model can be used for the forward modeling of light transport during endoscopically diffuse optical spectroscopy, light scattering spectroscopy, reflectance spectroscopy and other static optical detection or imaging technologies.
[Applications of near-infrared spectroscopy to analysis of traditional Chinese herbal medicine].
Li, Yan-Zhou; Min, Shun-Geng; Liu, Xia
2008-07-01
Analysis of traditional Chinese herbal medicine is of great importance to its quality control Conventional analysis methods can not meet the requirement of rapid and on-line analysis because of complex process more experiences or needed. In recent years, near-infrared spectroscopy technique has been used for rapid determination of active components, on-line quality control, identification of counterfeit and discrimination of geographical origins of herbal medicines and so on, due to its advantages of simple pretreatment, high efficiency, convenience to use solid diffuse reflection spectroscopy and fiber. In the present paper, the principles and methods of near-infrared spectroscopy technique are introduced concisely. Especially, the applications of this technique in quantitative analysis and qualitative analysis of traditional Chinese herbal medicine are reviewed.
Autofluorescence and diffuse reflectance patterns in cervical spectroscopy
NASA Astrophysics Data System (ADS)
Marin, Nena Maribel
Fluorescence and diffuse reflectance spectroscopy are two new optical technologies, which have shown promise to aid in the real time, non-invasive identification of cancers and precancers. Spectral patterns carry a fingerprint of scattering, absorption and fluorescence properties in tissue. Scattering, absorption and fluorescence in tissue are directly affected by biological features that are diagnostically significant, such as nuclear size, micro-vessel density, volume fraction of collagen fibers, tissue oxygenation and cell metabolism. Thus, analysis of spectral patterns can unlock a wealth of information directly related with the onset and progression of disease. Data from a Phase II clinical trial to assess the technical efficacy of fluorescence and diffuse reflectance spectroscopy acquired from 850 women at three clinical locations with two research grade optical devices is calibrated and analyzed. Tools to process and standardize spectra so that data from multiple spectrometers can be combined and analyzed are presented. Methodologies for calibration and quality assurance of optical systems are established to simplify design issues and ensure validity of data for future clinical trials. Empirically based algorithms, using multivariate statistical approaches are applied to spectra and evaluated as a clinical diagnostic tool. Physically based algorithms, using mathematical models of light propagation in tissue are presented. The presented mathematical model combines a diffusion theory in P3 approximation reflectance model and a 2-layer fluorescence model using exponential attenuation and diffusion theory. The resulting adjoint fluorescence and reflectance model extracts twelve optical properties characterizing fluorescence efficiency of cervical epithelium and stroma fluorophores, stromal hemoglobin and collagen absorption, oxygen saturation, and stromal scattering strength and shape. Validations with Monte Carlo simulations show that adjoint model extracted optical properties of the epithelium and the stroma can be estimated accurately. Adjoint model is applied to 926 clinical measurements from 503 patients. Mean values of extracted optical properties have demonstrated to characterize the biological changes associated with dysplastic progression. Finally, penalized logistic regression algorithms are applied to discriminate dysplastic stages in tissue based on extracted optical features. This work provides understandable and interpretable information regarding predictive and generalization ability of optical spectroscopy in neoplastic changes using a minimum subset of optical measurements. Ultimately these methodologies would facilitate the transfer of these optical technologies into clinical practice.
NASA Astrophysics Data System (ADS)
Wang, Chiao-Yi; Liao, Andy Ying Chi; Sung, Kung Bin
2018-02-01
Collagen provides skin structure integrity and its concentration is related to the severity of scars. The objective of this study is to develop a hand-held and relatively inexpensive system to detect changes of the dermal collagen concentration in vivo. Diffuse reflectance spectroscopy and two-layer diffusion model have often been used to quantify the collagen concentration and other optical properties of the skin. However, the influences of fat and muscle, which are just below the dermis, have not been thoroughly investigated. We applied Monte Carlo simulations to find source-detector separations most sensitive to changes in collagen absorption and identify four wavelengths between 650 nm and 1000 nm suitable for separating influences of other chromophores including melanin, oxyhemoglobin and deoxyhemoglobin. Our tissue model consisted of at least three layers including the epidermis, dermis and subcutaneous fat with an optional forth layer representing the muscle. Results showed that the reflectance of the three-layered tissue model differed significantly from that of the two-layered tissue model, and the additional muscle layer might also influence the reflectance depending on the thickness of the fat layer. In addition, whether scattering coefficients of the epidermis and dermis were the same significantly affected the reflectance. Differences in reflectance due to changes in the collagen concentration were distinct from those due to changes in scattering coefficients and other chromophores. Further in-vivo experiments are ongoing to to validate the proposed approach.
Quantification of tissue oxygenation levels using diffuse reflectance spectroscopy
NASA Astrophysics Data System (ADS)
B. S., Suresh Anand; N., Sujatha
2011-08-01
Tumor growth is characterized by increased metabolic activity. The light absorption profile of hemoglobin in dysplastic tissue is different from a normal tissue. Neovascularization is a hallmark of many diseases and can serve as a predictive biomarker for the detection of cancers. Spectroscopic techniques can provide information about the metabolic and morphological changes related to the progression of neoplasia. Diffuse reflectance spectroscopy (DRS) measures the absorption and scattering properties of a biological tissue and this method can provide clinically useful information for the early diagnosis of epithelial precancers. We used tissue simulating phantoms with absorbing and scattering molecules for the determination of total hemoglobin concentration, hemoglobin oxygen saturation and intensity difference between the deoxy and oxy hemoglobin bands. The results show promising approach for the differentiating normal and malignant states of a tissue.
Polarization mechanism in a ns laser-induced plasma spectroscopy of Al alloy
NASA Astrophysics Data System (ADS)
Aghababaei Nejad, Mahboobeh; Soltanolkotabi, Mahmood; Eslami Majd, Abdollah
2018-01-01
Polarization emission from aluminum alloy by ns laser-induced breakdown spectroscopy (LIBS) is carefully investigated in air using a non-gated CCD camera at integration time of 100 ms. First, the analysis reveals that the small polarization degree is the same for both continuum and discrete line emission spectra which also increases slowly with wavelength growth; second, laser fluence in the range of 347.81-550.10 J/cm2 has no significant changes in plasma polarization; and third, larger polarization in comparison with polarization introduced by preferential reflection of emission from the target surface (Fresnel reflectivity) is observed. The residual fluctuations of the anisotropic recombining plasma and the dynamic polarization of an ion's core are suggested as the possible main sources for observed polarized radiation in ns-LIBS.
Andreev Reflection Spectroscopy of Nb-doped Bi2Se3 Topological Insulator
NASA Astrophysics Data System (ADS)
Kurter, C.; Finck, A. D. K.; Qiu, Y.; Huemiller, E.; Weis, A.; Atkinson, J.; Medvedeva, J.; Hor, Y. S.; van Harlingen, D. J.
2015-03-01
Doped topological insulators are speculated to realize p-wave superconductivity with unusual low energy quasiparticles, such as surface Andreev bound states. We present point contact spectroscopy of thin exfoliated flakes of Nb-doped Bi2Se3 where superconductivity persists up to ~ 1 K, compared to 3.2 K in bulk crystals. The critical magnetic field is strongly anisotropic, consistent with quasi-2D behavior. Andreev reflection measurements of devices with low resistance contacts result in prominent BTK-like behavior with an enhanced conductance plateau at low bias. For high resistance contacts, we observe a split zero bias conductance anomaly and additional features at the superconducting gap. Our results suggest that this material is a promising platform for studying topological superconductivity. We acknowledge support from Microsoft Project Q.
Kuzmina, Ilona; Diebele, Ilze; Spigulis, Janis; Valeine, Lauma; Berzina, Anna; Abelite, Anita
2011-04-01
Optical fiber contact probe diffuse reflectance spectroscopy and remote multispectral imaging methods in the spectral range of 400 to 1100 nm were used for skin vascular malformation assessment and recovery tracing after treatment by intense pulsed light. The results confirmed that oxy-hemoglobin relative changes and the optical density difference between lesion and healthy skin in the spectral region 500 to 600 nm may be successfully used for objective appraisal of the therapy effect. Color redness parameter a* = 2 is suggested as a diagnostic border to distinguish healthy skin and vascular lesions, and as the indicator of phototreatment efficiency. Valuable diagnostic information on large area (>5 mm) lesions and lesions with uncertain borders can be proved by the multispectral imaging method.
NASA Astrophysics Data System (ADS)
Kuzmina, Ilona; Diebele, Ilze; Spigulis, Janis; Valeine, Lauma; Berzina, Anna; Abelite, Anita
2011-04-01
Optical fiber contact probe diffuse reflectance spectroscopy and remote multispectral imaging methods in the spectral range of 400 to 1100 nm were used for skin vascular malformation assessment and recovery tracing after treatment by intense pulsed light. The results confirmed that oxy-hemoglobin relative changes and the optical density difference between lesion and healthy skin in the spectral region 500 to 600 nm may be successfully used for objective appraisal of the therapy effect. Color redness parameter a* = 2 is suggested as a diagnostic border to distinguish healthy skin and vascular lesions, and as the indicator of phototreatment efficiency. Valuable diagnostic information on large area (>5 mm) lesions and lesions with uncertain borders can be proved by the multispectral imaging method.
Refurbishing of carbon contaminated pre-mirror of reflectivity beam line at Indus-1
NASA Astrophysics Data System (ADS)
Yadav, P. K.; Kumar, M.; Gupta, R. K.; Sinha, M.; Patel, H. S.; Modi, M. H.
2018-04-01
In recent days optics contamination and its refurbishing is a serious issue for synchrotron radiation beam line community. Here we refurbished a carbon contaminated mirror by Ar and O2 gas mixed (1:1) radio frequency plasma. For structural analysis pre and post characterization of the mirror was done by Soft X-ray reflectivity (SXRR), Raman Spectroscopy (RS) and Atomic force microscopy (AFM). Before refurbishing mirror, a low density graphitic carbon layer of thickness 400 Å with surface roughness about 55 Å and Au surface roughness 14Å was estimated by SXRR. After one hour RF plasma exposure it is observed by SXRR and Raman spectroscopy that carbon layer is completely removed. The AFM and SXRR results show that roughness of Au surface not increase after plasma exposure.
Accardo, Grazia; Cioffi, Raffaeke; Colangelo, Francesco; d’Angelo, Raffaele; De Stefano, Luca; Paglietti, Fderica
2014-01-01
Diffuse reflectance infrared Fourier transform (DRIFT) spectroscopy is a well-known technique for thin film characterization. Since all asbestos species exhibit intense adsorptions peaks in the 4000–400 cm−1 region of the infrared spectrum, a quantitative analysis of asbestos in bulk samples by DRIFT is possible. In this work, different quantitative analytical procedures have been used to quantify chrysotile content in bulk materials produced by building requalification: partial least squares (PLS) chemometrics, the Linear Calibration Curve Method (LCM) and the Method of Additions (MoA). Each method has its own pros and cons, but all give affordable results for material characterization: the amount of asbestos (around 10%, weight by weight) can be determined with precision and accuracy (errors less than 0.1). PMID:28788467
Reflectance spectroscopy of ferric sulfate-bearing montmorillonites as Mars soil analog materials
NASA Technical Reports Server (NTRS)
Bishop, J. L.; Pieters, C. M.; Burns, R. G.; Edwards, J. O.; Mancinelli, R. L.; Froschl, H.
1995-01-01
Spectroscopic analyses have shown that smectites enhanced in the laboratory with additional ferric species exhibit important similarities to those of the soils on Mars. Ferrihydrite in these chemically treated smectites has features in the visible to near-infrared region that resemble the energies and band strengths of features in reflectance spectra observed for several bright regions on Mars. New samples have been prepared with sulfate as well, because S was found by Viking to be a major component in the surface material on Mars. A suite of ferrihydrite-bearing and ferric sulfate-bearing montmorillonites, prepared with variable Fe3+ and S concentrations and variable pH conditions, has been analyzed using reflectance spectroscopy in the visible and infrared regions, Mossbauer spectroscopy at room temperature and 4 K, differential thermal analysis, and X-ray diffraction. These analyses support the formation of ferrihydrite of variable crystallinity in the ferrihydrite-bearing montmorillonites and a combination of schwertmannite and ferrihydrite in the ferric sulfate-bearing montmorillonites. Small quantities of poorly crystalline or nanophase forms of other ferric materials may also be present in these samples. The chemical formation conditions of the ferrihydrite-bearing and ferric sulfate-bearing montmorillonites influence the character of the low temperature Mossbauer sextets and the visible reflectance spectra. An absorption minimum is observed at 0.88-0.89 micrometers in spectra of the ferric sulfate-bearing samples, and at 0.89-0.92 micrometers in spectra of the ferrihydrate-bearing montmorillonites. Mossbauer spectra of the ferric sulfate-bearing montmorillonites indicate variable concentrations of ferrihydrite and schwertmannite in the interlaminar spaces and along grain surfaces. Dehydration under reduced atmospheric pressure conditions induces a greater effect on the adsorbed and interlayer water in ferrihydrite-bearing montmorillonite than on the water in ferric sulfate-bearing montmorillonite. Reflectance spectra of ferric sulfate-bearing montmorillonite include a strong 3-micrometers band that is more resistant to dry atmospheric conditions than the 3-micrometers band in spectra of similarly prepared ferrihydrite-bearing montmorillonites.
NASA Technical Reports Server (NTRS)
Orenberg, J. B.; Handy, J.; Quinn, R.
1992-01-01
Because of the power of remote sensing reflectance spectroscopy in determining mineralogy, it has been used as the major method of identifying a possible mineral analogue of the martian surface. A summary of proposed martian surface compositions from reflectance spectroscopy before 1979 was presented by Singer et al. Since that time, iron-rich montmorillonite clay, nanocrystalline or nanophase hematite, and palagonite have been suggested as Mars soil analogue materials. Palagonite in petrological terms is best described as an amorphous, hydrated, ferric iron, silica gel. Montmorillonite is a member of the smectite clay group, and its structure is characterized by an octahedral sheet in coordination with two tetrahedral sheets in which oxygen atoms are shared. The crystal unity of montmorillonite is well defined in contrast to palagonite where it is considered amorphous or poorly crystalline at best. Because of the absence of the diagnostic strong 2.2-micron reflectance band characteristic of clays in the near-infrared (NIR) spectrum of Mars and palagonite and based upon a consideration of wide wavelength coverage (0.3-50 microns), Roush et al. concluded that palagonite is a more likely Mars surface analogue. In spite of the spectral agreement of palagonite and the Mars reflectance spectrum in the 2.2-micron region, palagonite shows poor correspondence with the results of the Viking LR experiment. In contrast, iron-rich montmorillonite clays show relatively good agreement with the results of the Viking LR experiment. This spectral study was undertaken to evaluate the spectral properties of mixtures of palagonite and Mars analogue iron-rich montmorillonite clay (16-18 wt. percent Fe as Fe2O3) as a Mars surface mineralogical model. Mixtures of minerals as Mars surface analogue materials have been studied before, but the mixtures were restricted to crystalline clays and iron oxides.
Chemical composition of felt-tip pen inks.
Germinario, Giulia; Garrappa, Silvia; D'Ambrosio, Valeria; van der Werf, Inez Dorothé; Sabbatini, Luigia
2018-01-01
Felt-tip pens are frequently used for the realization of sketches, drawings, architectural projects, and other technical designs. The formulations of these inks are usually rather complex and may be associated to those of modern paint materials where, next to the binding medium and pigments/dyes, solvents, fillers, emulsifiers, antioxidants, plasticizers, light stabilizers, biocides, and so on are commonly added. Felt-tip pen inks are extremely sensitive to degradation and especially exposure to light may cause chromatic changes and fading. In this study, we report on the complete chemical characterization of modern felt-tip pen inks that are commercially available and commonly used for the realization of artworks. Three brands of felt-tip pens (Faber-Castell, Edding, and Stabilo) were investigated with complementary analytical techniques such as thin-layer chromatography (TLC), VIS-reflectance spectroscopy, μ-Raman spectroscopy, surface-enhanced Raman spectroscopy (SERS), pyrolysis-gas chromatography-mass spectrometry (Py-GC-MS), GC-MS, and Fourier transform infrared (FTIR) spectroscopy. The use of TLC proved to be very powerful in the study of complex mixtures of synthetic dyes. First derivatives of the reflectance spectra acquired on the TLC spots were useful in the preliminary identification of the dye, followed by Raman spectroscopy and SERS, which allowed for the unambiguous determination of the chemical composition of the pigments (phthalocyanines, dioxazines, and azo pigments) and dyes (azo dyes, triarylmethanes, xanthenes). FTIR spectroscopy was used especially for the detection of additives, as well as for confirming the nature of solvents and dyes/pigments. Finally, (Py-)GC-MS data provided information on the binders (styrene-acrylic resins, plant gums), solvents, and additives, as well as on pigments and dyes.
Karlowatz, M; Kraft, M; Mizaikoff, B
2004-05-01
Attenuated total reflection mid-infrared spectroscopy is applied for simultaneous detection and quantification of the environmentally relevant analytes benzene, toluene, and the three xylene isomers. The analytes are enriched into a thin polymer membrane coated onto the surface of an internal reflection waveguide, which is exposed to the aqueous sample. Direct detection of analytes permeating into the polymer coating is performed by utilizing evanescent field spectroscopy in the fingerprint range (>10 microm) of the mid-infrared (MIR) spectrum (3-20 microm) without additional sample preparation. All investigated compounds are characterized by well-separated absorption features in the evaluated wavelength regime. Hence, data evaluation was performed by integration of the respective absorption peaks. Limits of detection lower than 20 ppb (v/v) for all xylene isomers, 45 ppb (v/v) for benzene, and 80 ppb (v/v) for toluene have been achieved. The straightforward experimental setup and the achieved detection limits for these environmentally relevant volatile organic compounds in the low-ppb concentration range reveal a substantial potential of MIR evanescent field sensing devices for on-line in situ environmental analysis.
NASA Astrophysics Data System (ADS)
Kumar, Raj; Sharma, Vishal
2017-03-01
The present research is focused on the analysis of writing inks using destructive UV-Vis spectroscopy (dissolution of ink by the solvent) and non-destructive diffuse reflectance UV-Vis-NIR spectroscopy along with Chemometrics. Fifty seven samples of blue ballpoint pen inks were analyzed under optimum conditions to determine the differences in spectral features of inks among same and different manufacturers. Normalization was performed on the spectroscopic data before chemometric analysis. Principal Component Analysis (PCA) and K-mean cluster analysis were used on the data to ascertain whether the blue ballpoint pen inks could be differentiated by their UV-Vis/UV-Vis NIR spectra. The discriminating power is calculated by qualitative analysis by the visual comparison of the spectra (absorbance peaks), produced by the destructive and non-destructive methods. In the latter two methods, the pairwise comparison is made by incorporating the clustering method. It is found that chemometric method provides better discriminating power (98.72% and 99.46%, in destructive and non-destructive, respectively) in comparison to the qualitative analysis (69.67%).
NASA Astrophysics Data System (ADS)
Belau, Markus; Ninck, Markus; Hering, Gernot; Spinelli, Lorenzo; Contini, Davide; Torricelli, Alessandro; Gisler, Thomas
2010-09-01
We introduce a method for noninvasively measuring muscle contraction in vivo, based on near-infrared diffusing-wave spectroscopy (DWS). The method exploits the information about time-dependent shear motions within the contracting muscle that are contained in the temporal autocorrelation function g(1)(τ,t) of the multiply scattered light field measured as a function of lag time, τ, and time after stimulus, t. The analysis of g(1)(τ,t) measured on the human M. biceps brachii during repetitive electrical stimulation, using optical properties measured with time-resolved reflectance spectroscopy, shows that the tissue dynamics giving rise to the speckle fluctuations can be described by a combination of diffusion and shearing. The evolution of the tissue Cauchy strain e(t) shows a strong correlation with the force, indicating that a significant part of the shear observed with DWS is due to muscle contraction. The evolution of the DWS decay time shows quantitative differences between the M. biceps brachii and the M. gastrocnemius, suggesting that DWS allows to discriminate contraction of fast- and slow-twitch muscle fibers.
NASA Astrophysics Data System (ADS)
Yen, Y. T.; Hu, Rongwei; Petrovic, C.; Yeh, K. W.; Wu, M. K.; Wei, J. Y. T.
2012-02-01
We report on cryomagnetic point-contact Andreev reflection spectroscopy performed on single crystals of superconducting FeTe1-xSx and FeTe1-xSex. The samples are cleaved in-situ and the measurements are carried out at temperatures down to 4.2K and in a field up to 9T. At base temperature and zero field, we observe a cone-shaped hump at lower voltages in the conductance spectra with no dips at zero bias and a linear background at higher voltages. The spectral evolution of gap size, zero-bias conductance, and excess spectral area are analyzed as a function of temperature and field. Further spectral analysis is carried out using theoretical models of conductance spectra in multiband superconductors [1,2] and of gap symmetry in Fe-based superconductors [3]. The role of interstitial iron is also considered, by comparison with atomically-resolved scanning tunneling spectroscopy data.[4pt] [1] V. Lukic and E.J. Nicol, PRB 76, 144508 (2007) [2] A. Golubov et al., PRL 103, 077003 (2009) [3] P.J. Hirschfeld et al., RPP 74, 124508 (2011)
In-Field Diffuse Ultraviolet Spectroscopy and Imaging of the Stardust Sample Return Capsule
NASA Technical Reports Server (NTRS)
Pugel, D. Elizabeth; Stackpoole, Mairead; McNamara, Karen; Schwartz, C.; Warren, J.; Kontinos, Dean
2008-01-01
In-field diffuse Ultraviolet (UV) spectroscopy and imaging systems were developed for the purposes of evaluating the surface chemical composition of spacecraft thermal control coatings and materials. The investigation of these systems and the compilation of an associated UV reflectance and luminescence database were conducted using the Stardust Sample Return Capsule (SRC), located at the Johnson Space Center. Spectral responses of the surfaces of the Stardust forebody and aftbody in both reflectance and fluorescence modes were examined post-flight. In this paper, we report on two primary findings of in-field diffuse UV spectroscopy and imaging: (1) deduction of the thermal history of thermal control coatings of the forebody and (2) bond line variations in the aftbody. In the forebody, the thermal history of thermal control coatings may be deduced from the presence of particular semiconducting defect states associated with ZnO, a common emissivity constituent in thermal control coatings. A spatial dependence of this history was mapped for these regions. In the aftbody, luminescing defect states, associated with Si and SiO2 color centers were found along regions of bond variability.
NASA Astrophysics Data System (ADS)
Kotula, Anthony P.; Meyer, Matthew W.; De Vito, Francesca; Plog, Jan; Hight Walker, Angela R.; Migler, Kalman B.
2016-10-01
The design and performance of an instrument capable of simultaneous Raman spectroscopy, rheology, and optical microscopy are described. The instrument couples a Raman spectrometer and optical microscope to a rotational rheometer through an optically transparent base, and the resulting simultaneous measurements are particularly advantageous in situations where flow properties vary due to either chemical or conformational changes in molecular structure, such as in crystallization, melting, gelation, or curing processes. Instrument performance is demonstrated on two material systems that show thermal transitions. First, we perform steady state rotational tests, Raman spectroscopy, and polarized reflection microscopy during a melting transition in a cosmetic emulsion. Second, we perform small amplitude oscillatory shear measurements along with Raman spectroscopy and polarized reflection microscopy during crystallization of a high density polyethylene. The instrument can be applied to study structure-property relationships in a variety of soft materials including thermoset resins, liquid crystalline materials, colloidal suspensions undergoing sol-gel processes, and biomacromolecules. Official contribution of the National Institute of Standards and Technology; not subject to copyright in the United States.
Agustsson, Jon; Akermann, Oliver; Barry, D Andrew; Rossi, Luca
2014-08-01
Water contamination is an important environmental concern underlining the need for reliable real-time information on contaminant concentrations in natural waters. Here, a new non-contact UV-Vis spectroscopic approach for monitoring contaminants in water, and especially wastewater, is proposed. Diffuse reflectance UV-Vis spectroscopy was applied to measure simultaneously the chemical oxygen demand (COD) and turbidity (TUR) concentrations in water. The measurements were carried out in the wavelength range from 200-1100 nm. The measured spectra were analysed using partial-least-squares (PLS) regression. The correlation coefficient between the measured and the reference concentrations of COD and TUR in the water samples were R(2) = 0.85 and 0.96, respectively. These results highlight the potential of non-contact UV-Vis spectroscopy for the assessment of water contamination. A system built on the concept would be able to monitor wastewater pollution continuously, without the need for laborious sample collection and subsequent laboratory analysis. Furthermore, since no parts of the system are in contact with the wastewater stream the need for maintenance is minimised.
Estimating soil zinc concentrations using reflectance spectroscopy
NASA Astrophysics Data System (ADS)
Sun, Weichao; Zhang, Xia
2017-06-01
Soil contamination by heavy metals has been an increasingly severe threat to nature environment and human health. Efficiently investigation of contamination status is essential to soil protection and remediation. Visible and near-infrared reflectance spectroscopy (VNIRS) has been regarded as an alternative for monitoring soil contamination by heavy metals. Generally, the entire VNIR spectral bands are employed to estimate heavy metal concentration, which lacks interpretability and requires much calculation. In this study, 74 soil samples were collected from Hunan Province, China and their reflectance spectra were used to estimate zinc (Zn) concentration in soil. Organic matter and clay minerals have strong adsorption for Zn in soil. Spectral bands associated with organic matter and clay minerals were used for estimation with genetic algorithm based partial least square regression (GA-PLSR). The entire VNIR spectral bands, the bands associated with organic matter and the bands associated with clay minerals were incorporated as comparisons. Root mean square error of prediction, residual prediction deviation, and coefficient of determination (R2) for the model developed using combined bands of organic matter and clay minerals were 329.65 mg kg-1, 1.96 and 0.73, which is better than 341.88 mg kg-1, 1.89 and 0.71 for the entire VNIR spectral bands, 492.65 mg kg-1, 1.31 and 0.40 for the organic matter, and 430.26 mg kg-1, 1.50 and 0.54 for the clay minerals. Additionally, in consideration of atmospheric water vapor absorption in field spectra measurement, combined bands of organic matter and absorption around 2200 nm were used for estimation and achieved high prediction accuracy with R2 reached 0.640. The results indicate huge potential of soil reflectance spectroscopy in estimating Zn concentrations in soil.
P-doped strontium titanate grown using two target pulsed laser deposition for thin film solar cells
NASA Astrophysics Data System (ADS)
Man, Hamdi
Thin-film solar cells made of Mg-doped SrTiO3 p-type absorbers are promising candidates for clean energy generation. This material shows p-type conductivity and also demonstrates reasonable absorption of light. In addition, p-type SrTiO3 can be deposited as thin films so that the cost can be lower than the competing methods. In this work, Mg-doped SrTiO3 (STO) thin-films were synthesized and analyzed in order to observe their potential to be employed as the base semiconductor in photovoltaic applications. Mg-doped STO thin-films were grown by using pulsed laser deposition (PLD) using a frequency quadrupled Yttrium Aluminum Garnet (YAG) laser and with a substrate that was heated by back surface absorption of infrared (IR) laser light. The samples were characterized using X-ray photoelectron spectroscopy (XPS) and it was observed that Mg atoms were doped successfully in the stoichiometry. Reflection high energy electron diffraction (RHEED) spectroscopy proved that the thin films were polycrystalline. Kelvin Probe work function measurements indicated that the work function of the films were 4.167 eV after annealing. UV/Vis Reflection spectroscopy showed that Mg-doped STO thin-films do not reflect significantly except in the ultraviolet region of the spectrum where the reflection percentage increased up to 80%. Self-doped STO thin-films, Indium Tin Oxide (ITO) thin films and stainless steel foil (SSF) were studied in order to observe their characteristics before employing them in Mg-doped STO based solar cells. Self-doped STO thin films were grown using PLD and the results showed that they are capable of serving as the n-type semiconductor in solar cell applications with oxygen vacancies in their structure and low reflectivity. Indium Tin Oxide thin-films grown by PLD system showed low 25-50 ?/square sheet resistance and very low reflection features. Finally, commercially available stainless steel foil substrates were excellent substrates for the inexpensive growth of these novel solar cells.
Polarimetry and infrared spectroscopy in the detection of low-volatility chemical threats
NASA Astrophysics Data System (ADS)
Petryk, Michael W. P.; Marenco, Armando J.
2011-05-01
The polarization modulation infrared reflection absorption spectroscopy (PMIRRAS) spectra of the nerve agents GB (O-isopropyl methylphosphonofluoridate) and GF (cyclohexyl methylphoshonofluoridate) were recorded for the first time. A comparison of these spectra with the nerve agent VX (ethyl S-2-diisopropylaminoethyl methylphosphonothiolate) and the spectra of some trialkyl phosphates indicates that it is easy to distinguish between chemical warfare agents and simulants on militarily-relevant surfaces using PMIRRAS.
Optical diagnostics of mercuric iodide crystal growth
NASA Astrophysics Data System (ADS)
Burger, A.; Morgan, S. H.; Silberman, E.; Nason, D.
Two optical methods were recently developed for in situ monitoring of the growth process of mercuric iodide crystals. The first method uses resonance fluorescence spectroscopy (RFS) for the determination of iodine vapor present in the growth ampule, which is an important parameter in determining the stoichiometry, and therefore the quality of the crystals. The second method, Reflectance Spectroscopy Thermometry (RST) measures the crystal face temperature with a percent accuracy of plus or minus 1.5 C.
Optical diagnostics of mercuric iodide crystal growth
NASA Astrophysics Data System (ADS)
Burger, Arnold; Morgan, Steven H.; Silberman, Enrique; Nason, Donald
1991-12-01
Two optical methods were recently developed for in situ monitoring of the growth process of mercuric iodide crystals. The first method uses resonance fluorescence spectroscopy (RFS) for the determination of iodine vapor present in the growth ampule, which is an important parameter in determining the stoichiometry, and therefore the quality of the crystals. The second method, reflectance spectroscopy thermometry (RST) measures the crystal face temperature with a present accuracy of +/- 1.5 degree(s)C.
Characterization of Degradation Using Reflectance Spectroscopy (Postprint)
2013-08-01
AFRL/RXCA AUGUST 2013 Interim Report Distribution A. Approved for public release; distribution unlimited. See additional restrictions...ADDRESS. 1. REPORT DATE (DD-MM-YYYY) August 2013 2. REPORT TYPE Interim 3. DATES COVERED (From – To) 25 June 2009 – 21 July 2013 4. TITLE AND...Masiello, and J. H. Simmons, Journal of non-crystalline solids 275, 72–82 (2000). 10. C. Keefe , Journal of molecular spectroscopy 205, 261–268 (2001). 11. H
Miró, Manuel; Jimoh, Modupe; Frenzel, Wolfgang
2005-05-01
In this paper, a novel concept is presented for automatic microsampling and continuous monitoring of metal ions in soils with minimum disturbance of the sampling site. It involves a hollow-fiber microdialyser that is implanted in the soil body as a miniaturized sensing device. The idea behind microdialysis in this application is to mimic the function of a passive sampler to predict the actual, rather than potential, mobility and bioavailability of metal traces. Although almost quantitative dialysis recoveries were obtained for lead (> or = 98%) from aqueous model solutions with sufficiently long capillaries (l > or = 30 mm, 200 microm i.d.) at perfusion rates of 2.0 microL min(-1), the resistance of an inert soil matrix was found to reduce metal uptake by 30%. Preliminary investigation of the potential of the microdialysis analyser for risk assessment of soil pollution, and for metal partitioning studies, were performed by implanting the dedicated probe in a laboratory-made soil column and hyphenating it with electrothermal atomic absorption spectrometry (ETAAS), so that minute, well-defined volumes of clean microdialysates were injected on-line into the graphite furnace. A noteworthy feature of the implanted microdialysis-based device is the capability to follow the kinetics of metal release under simulated natural scenarios or anthropogenic actions. An ancillary flow set-up was arranged in such a way that a continuous flow of leaching solution--mild extractant (10(-2) mol L(-1) CaCl2), acidic solution (10(-3) mol L(-1) HNO3), or chelating agent (10(-4) or 10(-2) mol L(-1) EDTA)--was maintained through the soil body, while the concentration trends of inorganic (un-bound) metal species at the soil-liquid interface could be monitored at near real-time. Hence, relevant qualitative and quantitative information about the various mobile fractions is obtained, and metal-soil phase associations can also be elucidated. Finally, stimulus-response schemes adapted from neurochemical applications and pharmacokinetic studies are to be extended to soil research as an alternative means of local monitoring of extraction processes after induction of a chemical change in the outer boundary of the permselective dialysis membrane.
NASA Astrophysics Data System (ADS)
Lahlou, Radia; Armstrong, Peter R.; Calvet, Nicolas; Shamim, Tariq
2017-06-01
Nitrate salt vapor deposition on the reflecting surface of a secondary concentrator placed on top of an open molten salt tank at 500 °C is investigated using a lab-scale setup over an 8h-exposure cycle. Deposition, consisting of mostly spherical particles, is characterized in terms of chemical composition using energy dispersive X-ray spectroscopy. The corresponding specular reflectance degradation both temporary (before washing off the salt deposits) and permanent (residual reflectance loss after cleaning), is measured at different incidence angles and at reference points located at different heights. Reflectance drop due to salt deposits is compared to the one resulting from dust deposition. Long-term reflectance degradation by means of corrosion needs to be further studied through suitable accelerated aging tests.
Quantitative reflection spectroscopy at the human ocular fundus
NASA Astrophysics Data System (ADS)
Hammer, Martin; Schweitzer, Dietrich
2002-01-01
A new model of the reflection of the human ocular fundus on the basis of the adding-doubling method, an approximate solution of the radiative transport equation, is described. This model enables the calculation of the concentrations of xanthophyll in the retina, of melanin in the retinal pigment epithelium and the choroid, and of haemoglobin in the choroid from fundus reflection spectra. The concentration values found in 12 healthy subjects are in excellent agreement with published data. In individual cases of pathologic fundus alterations, possible benefits to the ophthalmologic diagnostics are demonstrated.
NASA Astrophysics Data System (ADS)
Pérez-Rodríguez, Marta; Horák-Terra, Ingrid; Rodríguez-Lado, Luis; Martínez Cortizas, Antonio
2016-11-01
Despite its potential, infrared spectroscopy combined with multivariate statistics has been seldom used to model peat properties with environmental value, such us the concentration of potentially toxic metals. In this research, we applied attenuated total reflectance (ATR) Fourier-Transform Infrared (FTIR) spectroscopy to evaluate the ability of the technique to predict mercury concentrations in late-Pleistocene/Holocene peat from a minerogenic peatland from Minas Gerais (Brazil). Mercury concentrations were analysed using a Milestone DMA-80 analyzer and attenuated total reflectance FTIR-ATR was performed using a Gladi-ATR (Pike Technologies) in the mid IR spectrum (4000-400 cm- 1). Concentrations were modelled using principal components (PCR) and partial least squares regression (PLS). The performance of the models varied between moderate and very good (R2 0.67-0.90), with low RMSD values (0.35-1.06). A PLS model based on three latent vectors (LV1 to LV3) provided the best (R2 0.90, RMSD 0.35) results. LV1 reflected total organic matter content versus mineral matter (mainly quartz from local fluxes), LV2 was related to dust deposition from regional sources, and LV3 reflected peat organic matter decomposition. Compared to a previous investigation based on geochemical data, the spectroscopy-based PLS model performed better, but it has to be complemented with additional data (as δ13 C ratios) to reliably reproduce the changes of the factors controlling mercury accumulation over time. This, time- and cost-effective, methodology may help to develop multi-core approaches to study the within and between mire (of a similar type and area) variability in mercury accumulation, and probably also other peat properties. Fig. S2 Loadings weights of the three and two significant components from the direct (dPCR) and transposed (trPCR) PCR models. Fig. S3 Depth records of the cumulative effects of the factors involved in the variation of mercury concentrations. Left, MIR-PLS model; centre, MIR-PLS + δ13 C data model; right, geochemical model from Pérez-Rodríguez et al. [44].
Non-destructive evaluation of specialty coating degradation using terahertz time-domain spectroscopy
NASA Astrophysics Data System (ADS)
Nicoletti, Carley R.; Cramer, Laura; Fletcher, Alan; Zimdars, David; Iqbal, Zafar; Federici, John F.
2017-05-01
The Terahertz Time Domain Reflection Spectroscopy (THz-TDS) method of paint layer diagnostics is a non-contact electromagnetic technique analogous to pulsed-ultrasound with the added capability of spectroscopic characterization. The THz-TDS sensor emits a near-single cycle electromagnetic pulse with a bandwidth from 0.1 to 3 THz. This wide bandwidth pulse is focused on the coating, and echo pulses are generated from each interface (air-coating, layer-layer, coating-substrate). In this paper, the THz-TDS method is applied to specialty aircraft coatings. The THz-TDS method is able to penetrate the whole coating stack and sample the properties of each layer. Because the reflected pulses from individual layers typically overlap in time, the complex permittivity function and thickness of each layer is determined by a best fit of the measured reflection (either in time or frequency domain) to a layered model of the paint. The THz- TDS method is applied to specialty coatings prior to and during accelerated aging on a series of test coupons. The coupons are also examined during aging using ATR (attenuated total reflectance)-FTIR spectroscopy, Raman scattering spectroscopy, and Scanning Electron Microscopy (SEM) to ascertain, quantify, and understand the breakdown mechanisms of the coatings. In addition, the same samples are characterized using THz-TDS techniques to determine if the THz-TDS method can be utilized as a non-destructive evaluation technique to sense degradation of the coatings. Our results suggest that the degradation mechanism begins in the top coat layer. In this layer, 254 nm UV illumination in combination with the presence of moisture works partially with oxides as catalysts to decompose the polymer matrix thereby creating porosity in the top coat layer. Since the catalytic effect is partial, loss of the oxides by chemical reaction can also occur. As the topcoat layer becomes more porous, it allows water vapor to permeate the topcoat layer and interact with the rain erosion layer via carbonization of the polymer matrix in the rain erosion layer. The presence of the salt accelerates the pitting degradation. The goal of this paper is to determine if THz-TDS can be used to sense degradation of the coating.
Epi-cleaning of Ge/GeSn heterostructures
DOE Office of Scientific and Technical Information (OSTI.GOV)
Di Gaspare, L.; Sabbagh, D.; De Seta, M.
2015-01-28
We demonstrate a very-low temperature cleaning technique based on atomic hydrogen irradiation for highly (1%) tensile strained Ge epilayers grown on metastable, partially strain relaxed GeSn buffer layers. Atomic hydrogen is obtained by catalytic cracking of hydrogen gas on a hot tungsten filament in an ultra-high vacuum chamber. X-ray photoemission spectroscopy, reflection high energy electron spectroscopy, atomic force microscopy, secondary ion mass spectroscopy, and micro-Raman showed that an O- and C-free Ge surface was achieved, while maintaining the same roughness and strain condition of the as-deposited sample and without any Sn segregation, at a process temperature in the 100–300 °C range.
Epi-cleaning of Ge/GeSn heterostructures
NASA Astrophysics Data System (ADS)
Di Gaspare, L.; Sabbagh, D.; De Seta, M.; Sodo, A.; Wirths, S.; Buca, D.; Zaumseil, P.; Schroeder, T.; Capellini, G.
2015-01-01
We demonstrate a very-low temperature cleaning technique based on atomic hydrogen irradiation for highly (1%) tensile strained Ge epilayers grown on metastable, partially strain relaxed GeSn buffer layers. Atomic hydrogen is obtained by catalytic cracking of hydrogen gas on a hot tungsten filament in an ultra-high vacuum chamber. X-ray photoemission spectroscopy, reflection high energy electron spectroscopy, atomic force microscopy, secondary ion mass spectroscopy, and micro-Raman showed that an O- and C-free Ge surface was achieved, while maintaining the same roughness and strain condition of the as-deposited sample and without any Sn segregation, at a process temperature in the 100-300 °C range.
Evaluation of bone quality in osteoporosis model mice by Raman spectroscopy
NASA Astrophysics Data System (ADS)
Ishimaru, Yasumitsu; Oshima, Yusuke; Imai, Yuuki; Iimura, Tadahiro; Takanezawa, Sota; Hino, Kazunori; Miura, Hiromasa
2017-04-01
To evaluate the bone quality in the osteoporosis, we generated sciatic nerve resection (NX) mice as an osteoporosis model and analyzed by Raman spectroscopy. Raman spectra were measured in anterior cortical surface of the proximal tibia at 5 points in each bone. After that, the samples were fixed with 70% ethanol. We then performed DXA and μCT measurement. Raman peak intensity ratios were significantly different between NX and Control. Those changes in the Raman peak intensity ratios may reflect loss of bone quality in the osteoporosis model. Raman spectroscopy is a promising technique for measuring the bone quality and bone strength.
Montagner, Cristina; Sanches, Diogo; Pedroso, Joana; Melo, Maria João; Vilarigues, Márcia
2013-02-15
The present paper describes the main results obtained from the characterization of a wide range of natural and synthetic ochre samples used in Portugal from the 19th to the 20th century, including powder and oil painting samples. The powder ochre samples came from several commercial distributors and from the collection of Joaquim Rodrigo (1912-1997), a leading Portuguese artist, particularly active during the sixties and seventies. The micro-samples of oil painting tubes came from the Museu Nacional de Arte Contemporânea-Museu do Chiado (National Museum of Contemporary Art-Chiado Museum) in Lisbon and were used by Columbano Bordalo Pinheiro (1857-1929), one of the most prominent naturalist Portuguese painters. These tubes were produced by the main 19th century colourmen: Winsor & Newton, Morin et Janet, Maison Merlin, and Lefranc. The samples have been studied using μ-Fourier Transform Infrared Spectroscopy (μ-FTIR), Raman microscopy, μ-Energy Dispersive X-ray fluorescence (μ-EDXRF), and X-ray diffraction (XRD). The analyzed ochres were found to be a mixture of several components: iron oxides and hydroxides in matrixes with kaolinite, gypsum and chalk. The results obtained allowed to identify and characterize the ochres according to their matrix and chromophores. The main chromophores where identified by Raman microscopy as being hematite, goethite and magnetite. The infrared analysis of the ochre samples allowed to divide them into groups, according to the composition of the matrix. It was possible to separate ochres containing kaolinite matrix and/or sulfate matrix from ochres where only iron oxides and/or hydroxides were detected. μ-EDXRF and Raman were the best techniques to identify umber, since the presence of elements such as manganese is characteristic of these pigments. μ-EDXRF also revealed the presence of significant amounts of arsenic in all Sienna tube paints. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Montagner, Cristina; Sanches, Diogo; Pedroso, Joana; Melo, Maria João; Vilarigues, Márcia
2013-02-01
The present paper describes the main results obtained from the characterization of a wide range of natural and synthetic ochre samples used in Portugal from the 19th to the 20th century, including powder and oil painting samples. The powder ochre samples came from several commercial distributors and from the collection of Joaquim Rodrigo (1912-1997), a leading Portuguese artist, particularly active during the sixties and seventies. The micro-samples of oil painting tubes came from the Museu Nacional de Arte Contemporânea-Museu do Chiado (National Museum of Contemporary Art-Chiado Museum) in Lisbon and were used by Columbano Bordalo Pinheiro (1857-1929), one of the most prominent naturalist Portuguese painters. These tubes were produced by the main 19th century colourmen: Winsor & Newton, Morin et Janet, Maison Merlin, and Lefranc. The samples have been studied using μ-Fourier Transform Infrared Spectroscopy (μ-FTIR), Raman microscopy, μ-Energy Dispersive X-ray fluorescence (μ-EDXRF), and X-ray diffraction (XRD). The analyzed ochres were found to be a mixture of several components: iron oxides and hydroxides in matrixes with kaolinite, gypsum and chalk. The results obtained allowed to identify and characterize the ochres according to their matrix and chromophores. The main chromophores where identified by Raman microscopy as being hematite, goethite and magnetite. The infrared analysis of the ochre samples allowed to divide them into groups, according to the composition of the matrix. It was possible to separate ochres containing kaolinite matrix and/or sulfate matrix from ochres where only iron oxides and/or hydroxides were detected. μ-EDXRF and Raman were the best techniques to identify umber, since the presence of elements such as manganese is characteristic of these pigments. μ-EDXRF also revealed the presence of significant amounts of arsenic in all Sienna tube paints.
On the challenges of using field spectroscopy to measure the impact of soil type on leaf traits
NASA Astrophysics Data System (ADS)
Nunes, Matheus H.; Davey, Matthew P.; Coomes, David A.
2017-07-01
Understanding the causes of variation in functional plant traits is a central issue in ecology, particularly in the context of global change. Spectroscopy is increasingly used for rapid and non-destructive estimation of foliar traits, but few studies have evaluated its accuracy when assessing phenotypic variation in multiple traits. Working with 24 chemical and physical leaf traits of six European tree species growing on strongly contrasting soil types (i.e. deep alluvium versus nearby shallow chalk), we asked (i) whether variability in leaf traits is greater between tree species or soil type, and (ii) whether field spectroscopy is effective at predicting intraspecific variation in leaf traits as well as interspecific differences. Analysis of variance showed that interspecific differences in traits were generally much stronger than intraspecific differences related to soil type, accounting for 25 % versus 5 % of total trait variation, respectively. Structural traits, phenolic defences and pigments were barely affected by soil type. In contrast, foliar concentrations of rock-derived nutrients did vary: P and K concentrations were lower on chalk than alluvial soils, while Ca, Mg, B, Mn and Zn concentrations were all higher, consistent with the findings of previous ecological studies. Foliar traits were predicted from 400 to 2500 nm reflectance spectra collected by field spectroscopy using partial least square regression, a method that is commonly employed in chemometrics. Pigments were best modelled using reflectance data from the visible region (400-700 nm), while all other traits were best modelled using reflectance data from the shortwave infrared region (1100-2500 nm). Spectroscopy delivered accurate predictions of species-level variation in traits. However, it was ineffective at detecting intraspecific variation in rock-derived nutrients (with the notable exception of P). The explanation for this failure is that rock-derived elements do not have absorption features in the 400-2500 nm region, and their estimation is indirect, relying on elemental concentrations covarying with structural traits that do have absorption features in that spectral region (constellation effects
). Since the structural traits did not vary with soil type, it was impossible for our regression models to predict intraspecific variation in rock-derived nutrients via constellation effects. This study demonstrates the value of spectroscopy for rapid, non-destructive estimation of foliar traits across species, but highlights problems with predicting intraspecific variation indirectly. We discuss the implications of these findings for mapping functional traits by airborne imaging spectroscopy.
A versatile optical microscope for time-dependent single-molecule and single-particle spectroscopy
NASA Astrophysics Data System (ADS)
Li, Hao; Yang, Haw
2018-03-01
This work reports the design and implementation of a multi-function optical microscope for time-dependent spectroscopy on single molecules and single nanoparticles. It integrates the now-routine single-object measurements into one standalone platform so that no reconfiguration is needed when switching between different types of sample or spectroscopy modes. The illumination modes include evanescent field through total internal reflection, dark-field illumination, and epi-excitation onto a diffraction-limited spot suitable for confocal detection. The detection modes include spectrally resolved line imaging, wide-field imaging with dual-color capability, and two-color single-element photon-counting detection. The switch between different spectroscopy and data acquisition modes is fully automated and executed through computer programming. The capability of this microscope is demonstrated through selected proof-of-principle experiments.
An historical overview of cavity-enhanced methods
NASA Astrophysics Data System (ADS)
Paldus, B. A.; Kachanov, A. A.
2005-10-01
An historical overview of laser-based, spectroscopic methods that employ high-finesse optical resonators is presented. The overview begins with the early work in atomic absorption (1962) and optical cavities (1974) that led to the first mirror reflectivity measurements in 1980. This paper concludes with very recent extensions of cavity-enhanced methods for the study of condensed-phase media and biological systems. Methods described here include cavity ring-down spectroscopy, integrated cavity output spectroscopy, and noise-immune cavity-enhanced optical heterodyne molecular spectroscopy. Given the explosive growth of the field over the past decade, this review does not attempt to present a comprehensive bibliography of all work published in cavity-enhanced spectroscopy, but rather strives to illustrate the rich history, creative diversity, and broad applications potential of these methods.
Metallic scattering lifetime measurements with terahertz time-domain spectroscopy
NASA Astrophysics Data System (ADS)
Lea, Graham Bryce
The momentum scattering lifetime is a fundamental parameter of metallic conduction that can be measured with terahertz time-domain spectroscopy. This technique has an important strength over optical reflectance spectroscopy: it is capable of measuring both the phase and the amplitude of the probing radiation. This allows simultaneous, independent measurements of the scattering lifetime and resistivity. Broadly, it is the precision of the phase measurement that determines the precision of scattering lifetime measurements. This thesis describes milliradian-level phase measurement refinements in the experimental technique and measures the conductivity anisotropy in the correlated electron system CaRuO3. These phase measurement refinements translate to femtosecond-level refinements in scattering lifetime measurements of thin metallic films. Keywords: terahertz time-domain spectroscopy, calcium ruthenate, ruthenium oxides, correlated electrons, experimental technique.
NASA Technical Reports Server (NTRS)
Pouch, J. J.; Alterovitz, S. A.; Warner, J. D.
1986-01-01
The amorphous dielectrics a-C:H and BN were deposited on III-V semiconductors. Optical band gaps as high as 3 eV were measured for a-C:H generated by C4H10 plasmas; a comparison was made with bad gaps obtained from films prepared by CH4 glow discharges. The ion beam deposited BN films exhibited amorphous behavior with band gaps on the order of 5 eV. Film compositions were studied by Auger electron spectroscopy (AES), x-ray photoelectron spectroscopy (XPS) and secondary ion mass spectrometry (SIMS). The optical properties were characterized by ellipsometry, UV/VIS absorption, and IR reflection and transmission. Etching rates of a-C:H subjected to O2 dicharges were determined.
A versatile optical microscope for time-dependent single-molecule and single-particle spectroscopy.
Li, Hao; Yang, Haw
2018-03-28
This work reports the design and implementation of a multi-function optical microscope for time-dependent spectroscopy on single molecules and single nanoparticles. It integrates the now-routine single-object measurements into one standalone platform so that no reconfiguration is needed when switching between different types of sample or spectroscopy modes. The illumination modes include evanescent field through total internal reflection, dark-field illumination, and epi-excitation onto a diffraction-limited spot suitable for confocal detection. The detection modes include spectrally resolved line imaging, wide-field imaging with dual-color capability, and two-color single-element photon-counting detection. The switch between different spectroscopy and data acquisition modes is fully automated and executed through computer programming. The capability of this microscope is demonstrated through selected proof-of-principle experiments.
System and technique for characterizing fluids using ultrasonic diffraction grating spectroscopy
Greenwood, Margaret S.
2005-04-12
A system for determining a property of a fluid based on ultrasonic diffraction grating spectroscopy includes a diffraction grating on a solid in contact with the fluid. An interrogation device delivers ultrasound through the solid and a captures a reflection spectrum from the diffraction grating. The reflection spectrum including a diffraction order equal to zero exhibits a peak whose location is used to determine speed of sound in the fluid. A separate measurement of the acoustic impedance is combined with the determined speed of sound to yield a measure of fluid density. A system for determining acoustic impedance includes an ultrasonic transducer on a first surface of a solid member, and an opposed second surface of the member is in contact with a fluid to be monitored. A longitudinal ultrasonic pulse is delivered through the solid member, and a multiplicity of pulse echoes caused by reflections of the ultrasonic pulse between the solid-fluid interface and the transducer-solid interface are detected. The decay rate of the detected echo amplitude as a function of echo number is used to determine acoustic impedance.
Sakota, Daisuke; Kani, Yuki; Kosaka, Ryo; Nishida, Masahiro; Maruyama, Osamu
2013-01-01
To achieve quantitative non-invasive optical diagnosis of blood abnormalities during extracorporeal circulation therapies, plasma surface reflectance spectroscopy was developed by implementing oblique-incidence optical fiber reflectometry on the surface of circulating blood. The reflected light in the wavelength range from 450 to 600 nm changed with respect to the plasma free hemoglobin level and could be used to quantify the free hemoglobin at an accuracy of 5.7 ± 3.5 mg/dL. In contrast, the spectrum did not changed by varying the hematocrit. In the wavelength range from 600 to 800 nm, the obtained spectrum was affected by both the hematocrit change and hemolysis. The linear correlation between the hematocrit value and the spectrum was confirmed at R(2) = 0.99. The feasibility of determining of the hematocrit of arbitrary hemolyzed blood was confirmed. The developed system permits the extraction of the optical characteristics of both plasma and red blood cells without centrifugation. The study establishes non-invasive optical diagnostics capable of analyzing the optical properties of both plasma and red blood cells.
Li, Junfeng; Wan, Xiaoxia; Bu, Yajing; Li, Chan; Liang, Jinxing; Liu, Qiang
2016-11-01
Noninvasive examination methods of chemical composition and particle size are presented here based on visible spectroscopy to achieve the identification and recording of mineral pigments used on ancient wall paintings. The normalized spectral curve, slope and curvature extracted from visible spectral reflectance are combined with adjustable weighting coefficients to construct the identification feature space, and Euclid distances between spectral reflectance from wall paintings and a reference database are calculated in the feature space as the discriminant criterion to identify the chemical composition of mineral pigments. A parametric relationship between the integral quantity of spectral reflectance and logarithm of mean particle size is established using a quadratic polynomial to accomplish the noninvasive prediction of mineral pigment particle size used on ancient wall paintings. The feasibility of the proposed methods is validated by the in situ nondestructive identification of the wall paintings in the Mogao Grottoes at Dunhuang. Chinese painting styles and historical evolution are then analyzed according to the identification results of 16 different grottoes constructed from the Sixteen Kingdoms to the Yuan Dynasty. © The Author(s) 2016.
NASA Astrophysics Data System (ADS)
González-Campuzano, R.; Saniger, J. M.; Mendoza, D.
2017-11-01
The size-controllable and ordered Al nanocavities and nanodomes arrays were synthesized by electrochemical anodization of aluminum using phosphoric acid, citric acid and mixture both acids. Few layer graphene (FLG) was transferred directly on top of Al nanostructures and their morphology were evaluated by scanning electron microscopy. The interaction between FLG and the plasmonic properties of Al nanostructures arrays were investigated based on specular reflectivity in the ultraviolet-visible-infrared range and Raman spectroscopy. We found that their optical reflectivity was dramatically reduced as compared with unstructured Al. At the same time pronounced reflectivity dips were detectable in the 200-896 nm wavelength range, which were ascribed to plasmonic resonances. The plasmonic properties of these nanostructures do not exhibit evident changes by the presence of FLG in the UV-vis range of the electromagnetic spectrum. By contrast, the surface-enhanced Raman spectroscopy of FLG was observed in nanocavities and nanodomes structures that result in an intensity increase of the characteristic G and 2D bands of FLG induced by the plasmonic properties of Al nanostructures.
Influence of earlobe thickness on near infrared spectroscopy
NASA Astrophysics Data System (ADS)
Jiang, Jingying; Wang, Tianpei; Li, Si; Li, Lin; Liu, Jiajia; Xu, Kexin
2017-03-01
Near-infrared spectroscopy has been recognized as a potential technology for noninvasive blood glucose sensing. However, the detected spectral signal is unstable mainly because of (1) the weak light absorption of glucose itself within NIR range, (2) the influence of temperature and individual differences of biotissue. Our previous results demonstrated that the synergistic effect of both transmittance and reflectance could enhance the strength of the detection signal. In this talk, we design a set of experiments to analyze the effect of earlobe thickness on Near Infrared spectroscopic measurement by using home-made optical fiber probe within the wavelength of 1000-1600nm. Firstly, we made a MC simulation of single-layer skin model and five-layer skin model to get the diffused transmittance spectra and diffused reflectance spectra under different optaical path lengths. And then we obtain the spectra of the earlobes from different volunteers by the same way. The experimental results showed that with the increase of the thickness,the light intensity of diffused transmittance decreases, and the light intensity of diffused reflectance remaines substantially unchanged.
Muñoz Morales, Aarón A; Vázquez Y Montiel, Sergio
2012-10-01
The determination of optical parameters of biological tissues is essential for the application of optical techniques in the diagnosis and treatment of diseases. Diffuse Reflection Spectroscopy is a widely used technique to analyze the optical characteristics of biological tissues. In this paper we show that by using diffuse reflectance spectra and a new mathematical model we can retrieve the optical parameters by applying an adjustment of the data with nonlinear least squares. In our model we represent the spectra using a Fourier series expansion finding mathematical relations between the polynomial coefficients and the optical parameters. In this first paper we use spectra generated by the Monte Carlo Multilayered Technique to simulate the propagation of photons in turbid media. Using these spectra we determine the behavior of Fourier series coefficients when varying the optical parameters of the medium under study. With this procedure we find mathematical relations between Fourier series coefficients and optical parameters. Finally, the results show that our method can retrieve the optical parameters of biological tissues with accuracy that is adequate for medical applications.
Optical spectroscopy of excited exciton states in MoS2 monolayers in van der Waals heterostructures
NASA Astrophysics Data System (ADS)
Robert, C.; Semina, M. A.; Cadiz, F.; Manca, M.; Courtade, E.; Taniguchi, T.; Watanabe, K.; Cai, H.; Tongay, S.; Lassagne, B.; Renucci, P.; Amand, T.; Marie, X.; Glazov, M. M.; Urbaszek, B.
2018-01-01
The optical properties of MoS2 monolayers are dominated by excitons, but for spectrally broad optical transitions in monolayers exfoliated directly onto SiO2 substrates detailed information on excited exciton states is inaccessible. Encapsulation in hexagonal boron nitride (hBN) allows approaching the homogenous exciton linewidth, but interferences in the van der Waals heterostructures make direct comparison between transitions in optical spectra with different oscillator strength more challenging. Here we reveal in reflectivity and in photoluminescence excitation spectroscopy the presence of excited states of the A exciton in MoS2 monolayers encapsulated in hBN layers of calibrated thickness, allowing us to extrapolate an exciton binding energy of ≈220 meV. We theoretically reproduce the energy separations and oscillator strengths measured in reflectivity by combining the exciton resonances calculated for a screened two-dimensional Coulomb potential with transfer matrix calculations of the reflectivity for the van der Waals structure. Our analysis shows a very different evolution of the exciton oscillator strength with principal quantum number for the screened Coulomb potential as compared to the ideal two-dimensional hydrogen model.
NASA Astrophysics Data System (ADS)
Hoeijmakers, H. J.; Snellen, I. A. G.; van Terwisga, S. E.
2018-02-01
Context. It is challenging to measure the starlight reflected from exoplanets because of the extreme contrast with their host stars. For hot Jupiters, this contrast is in the range of 10-6 to 10-4, depending on their albedo, radius and orbital distance. Searches for reflected light have been performed since the first hot Jupiters were discovered, but with very limited success because hot Jupiters tend to have low albedo values due to the general absence of reflective cloud decks. Aim. The aim of this study is to search for reflected light from τ Boo b, a hot Jupiter with one of the brightest host stars. Since its discovery in 1997, it has been the subject of several reflected-light searches using high-dispersion spectroscopy. Here we aim to combine these data in to a single meta-analysis. Methods: We analysed more than 2000 archival high-dispersion spectra obtained with the UVES, ESPaDOnS, NARVAL UES and HARPS-N spectrographs during various epochs between 1998 and 2013. Each spectrum was first cleaned of the stellar spectrum and subsequently cross-correlated with a PHOENIX model spectrum. These were then Doppler shifted to the planet rest-frame and co-added in time, weighted according to the expected signal-to-noise of the planet signal. Results: We reach a 3σ upper limit of the planet-to-star contrast of 1.5 × 10-5. Assuming a planet radius of 1.15 RJ, this corresponds to an optical albedo of between 400-700 nm. A low albedo is in line with secondary eclipse and phase curve observations of other hot Jupiters using space-based observatories, as well as theoretical predictions of their reflective properties.
Tanis, Erik; Evers, Danny J; Spliethoff, Jarich W; Pully, Vishnu V; Kuhlmann, Koert; van Coevorden, Frits; Hendriks, Benno H W; Sanders, Joyce; Prevoo, Warner; Ruers, Theo J M
2016-11-01
Over the last decade, an increasing effort has been put towards the implementation of optical guidance techniques to aid surgeons during cancer surgery. Diffuse reflectance spectroscopy (DRS) and fluorescence spectroscopy (FS) are two of these new techniques. The objective of this study is to investigate whether in vivo optical spectroscopy is able to accurately discriminate colorectal liver metastases (CRLM) from normal liver tissue in vivo. DRS and FS were incorporated at the tip of a needle and were used for in vivo tissue differentiation during resection of CRLM. Measurements were taken in and around the tumor lesions and measurement sites were marked and correlated to histology (i.e., normal liver tissue or tumor tissue). Patients with and without neoadjuvant systemic chemotherapy were included into the study. Four hundred and eighty-four measurements were taken in and near 19 liver lesions prior to resection. Overall sensitivity and specificity for DRS was 95% and 92%, respectively. Bile was the most discriminative parameter. The addition of FS did not improve the overall accuracy. Sensitivity and specificity was not hampered by neo-adjuvant chemotherapy; sensitivity and specificity after neo-adjuvant chemotherapy were 92% and 100%, respectively. We have successfully integrated spectroscopy technology into a disposable 15 Gauge optical needle and we have shown that DRS and FS can accurately discriminate CRLM from normal liver tissue in the in vivo setting regardless of whether the patient was pre-treated with systemic therapy. This technique makes in vivo guidance accessible for common surgical practice. Lasers Surg. Med. 48:820-827, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Geltner, I.; Hashimshony, D.; Zigler, A.
2002-07-01
We use a time-domain analysis method to characterize the outer layer of a multilayer structure regardless of the inner ones, thus simplifying the characterization of all the layers. We combine this method with THz reflection spectroscopy to detect nondestructively a hidden aluminum oxide layer under opaque paint and to measure its conductivity and high-frequency dielectric constant in the THz range.
1987-10-15
apparent shift of this band to higher energy with increasing coverage, observed at lower resolution (but higher sensitivity) in electron energy loss...apparent shift of this band to higher energy with increasing coverage, observed at lower resolution (but higher sen- sitivity) in electron energy ...11 using high-resolution electron energy -loss spectroscopy (EELS), is especially intriguing. 02 dissociates on this surface to populate two types of
Spectroscopic determination of ecologically relevant plant secondary metabolites
Couture, John J.; Singh, Aditya; Rubert-Nason, Kennedy F.; ...
2016-07-23
Spectroscopy has recently emerged as an effective method to accurately characterize leaf biochemistry in living tissue through the application of chemometric approaches to foliar optical data, but this approach has not been widely used for plant secondary metabolites. Here in this paper, we examine the ability of reflectance spectroscopy to quantify specific phenolic compounds in trembling aspen (Populus tremuloides) and paper birch (Betula papyrifera) that play influential roles in ecosystem functioning related to trophic-level interactions and nutrient cycling.
Probe pressure effects on human skin diffuse reflectance and fluorescence spectroscopy measurements
Lim, Liang; Nichols, Brandon; Rajaram, Narasimhan; Tunnell, James W.
2011-01-01
Diffuse reflectance and fluorescence spectroscopy are popular research techniques for noninvasive disease diagnostics. Most systems include an optical fiber probe that transmits and collects optical spectra in contact with the suspected lesion. The purpose of this study is to investigate probe pressure effects on human skin spectroscopic measurements. We conduct an in-vivo experiment on human skin tissue to study the short-term (<2 s) and long-term (>30 s) effects of probe pressure on diffuse reflectance and fluorescence measurements. Short-term light probe pressure (P0 < 9 mN∕mm2) effects are within 0 ± 10% on all physiological properties extracted from diffuse reflectance and fluorescence measurements, and less than 0 ± 5% for diagnostically significant physiological properties. Absorption decreases with site-specific variations due to blood being compressed out of the sampled volume. Reduced scattering coefficient variation is site specific. Intrinsic fluorescence shows a large standard error, although no specific pressure-related trend is observed. Differences in tissue structure and morphology contribute to site-specific probe pressure effects. Therefore, the effects of pressure can be minimized when the pressure is small and applied for a short amount of time; however, long-term and large pressures induce significant distortions in measured spectra. PMID:21280899
NASA Astrophysics Data System (ADS)
Bossard-Giannesini, Léo; Cruguel, Hervé; Lacaze, Emmanuelle; Pluchery, Olivier
2016-09-01
Gold nanoparticles (AuNPs) are known for their localized surface plasmon resonance (LSPR) that can be measured with UV-visible spectroscopy. AuNPs are often deposited on silicon substrates for various applications, and the LSPR is measured in reflection. In this case, optical spectra are measured by surface differential reflectance spectroscopy (SDRS) and the absorbance exhibits a negative peak. This article studies both experimentally and theoretically on the single layers of 16 nm diameter spherical gold nanoparticles (AuNPs) grafted on silicon. The morphology and surface density of AuNPs were investigated by atomic force microscopy (AFM). The plasmon response in transmission on the glass substrate and in reflection on the silicon substrate is described by an analytical model based on the Fresnel equations and the Maxwell-Garnett effective medium theory (FMG). The FMG model shows a strong dependence to the incidence angle of the light. At low incident angles, the peak appears negatively with a shallow intensity, and at angles above 30°, the usual positive shape of the plasmon is retrieved. The relevance of the FMG model is compared to the Mie theory within the dipolar approximation. We conclude that no Fano effect is responsible for this derivative shape. An easy-to-use formula is derived that agrees with our experimental data.
Identification of natural red and purple dyes on textiles by Fiber-optics Reflectance Spectroscopy.
Maynez-Rojas, M A; Casanova-González, E; Ruvalcaba-Sil, J L
2017-05-05
Understanding dye chemistry and dye processes is an important issue for studies of cultural heritage collections and science conservation. Fiber Optics Reflectance Spectroscopy (FORS) is a powerful technique, which allows preliminary dye identification, causing no damage or mechanical stress on the artworks subjected to analysis. Some information related to specific light scattering and absorption can be obtained in the UV-visible and infrared range (300-1400nm) and it is possible to discriminate the kind of support fiber in the near infrared region (1000-2500nm). The main spectral features of natural dye fibers samples, such as reflection maxima, inflection points and reflection minima, can be used in the differentiation of various red natural dyes. In this work, a set of dyed references were manufactured following Mexican recipes with red dyes (cochineal and brazilwood) in order to determine the characteristic FORS spectral features of fresh and aged dyed fibers for their identification in historical pieces. Based on these results, twenty-nine indigenous textiles belonging to the National Commission for the Development of Indigenous People of Mexico were studied. Cochineal and brazilwood were successfully identified by FORS in several pieces, as well as the mixture of cochineal and indigo for purple color. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Bachmann, K. J.; Cardelino, B. H.; Moore, C. E.; Cardelino, C. A.; Sukidi, N.; McCall, S.
1999-01-01
The purpose of this paper is to review modeling and real-time monitoring by robust methods of reflectance spectroscopy of organometallic chemical vapor deposition (OMCVD) processes in extreme regimes of pressure. The merits of p-polarized reflectance spectroscopy under the conditions of chemical beam epitaxy (CBE) and of internal transmission spectroscopy and principal angle spectroscopy at high pressure are assessed. In order to extend OMCVD to materials that exhibit large thermal decomposition pressure at their optimum growth temperature we have designed and built a differentially-pressure-controlled (DCP) OMCVD reactor for use at pressures greater than or equal to 6 atm. We also describe a compact hard-shell (CHS) reactor for extending the pressure range to 100 atm. At such very high pressure the decomposition of source vapors occurs in the vapor phase, and is coupled to flow dynamics and transport. Rate constants for homogeneous gas phase reactions can be predicted based on a combination of first principles and semi-empirical calculations. The pressure dependence of unimolecular rate constants is described by RRKM theory, but requires variational and anharmonicity corrections not included in presently available calculations with the exception of ammonia decomposition. Commercial codes that include chemical reactions and transport exist, but do not adequately cover at present the kinetics of heteroepitaxial crystal growth.
[The study of CO2 cavity enhanced absorption and highly sensitive absorption spectroscopy].
Pei, Shi-Xin; Gao, Xiao-Ming; Cui, Fen-Ping; Huang, Wei; Shao, Jie; Fan, Hong; Zhang, Wei-Jun
2005-12-01
Cavity enhanced absorption spectroscopy (CEAS) is a new spectral technology that is based on the cavity ring down absorption spectroscopy. In the present paper, a DFB encapsulation narrow line width tunable diode laser (TDL) was used as the light source. At the center output, the TDL radiation wavelength was 1.573 microm, and an optical cavity, which consisted of two high reflectivity mirrors (near 1.573 microm, the mirror reflectivity was about 0.994%), was used as a sample cell. A wavemeter was used to record the accurate frequency of the laser radiation. In the experiment, the method of scanning the optical cavity to change the cavity mode was used, when the laser frequency was coincident with one of the cavity mode; the laser radiation was coupled into the optical cavity and the detector could receive the light signals that escaped the optical cavity. As a result, the absorption spectrum of carbon dioxide weak absorption at low pressure was obtained with an absorption intensity of 1.816 x 10(-23) cm(-1) x (molecule x cm(-2)(-1) in a sample cell with a length of only 33.5 cm. An absorption sensitivity of about 3.62 x 10(-7) cm(-1) has been achieved. The experiment result indicated that the cavity enhanced absorption spectroscopy has the advantage of high sensivity, simple experimental setup, and easy operation.
Microplastics on sandy beaches of the Baja California Peninsula, Mexico.
Piñon-Colin, Teresita de Jesus; Rodriguez-Jimenez, Ruben; Pastrana-Corral, Miguel Angel; Rogel-Hernandez, Eduardo; Wakida, Fernando Toyohiko
2018-06-01
Microplastics have become a concern in recent years because of their negative impact on marine and freshwater environments. Twenty-one sandy beach sites were sampled to investigate the occurrence and distribution of microplastics on the sandy beaches of the Baja California Peninsula, Mexico, as well as their spectroscopic characterization and morphology. Microplastics were separated using the density method and identified using Attenuated Total Reflection Fourier Transform Infrared Spectroscopy (ATR-FTIR). The mean abundance of microplastics in the samples was 135 ± 92 particles kg−1, and fiber was the most abundant microplastic found in the samples, comprising 91% of the total microplastics identified. Attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR) analysis of the microplastics showed that the main polymers found in microplastics were polyacrylic, polyacrylamide, polyethylene terephthalate, polyesters, and nylon.
Sirisomboon, Panmanas; Chowbankrang, Rawiphan; Williams, Phil
2012-05-01
Near-infrared spectroscopy in diffuse reflection mode was used to evaluate the apparent viscosity of Para rubber field latex and concentrated latex over the wavelength range of 1100 to 2500 nm, using partial least square regression (PLSR). The model with ten principal components (PCs) developed using the raw spectra accurately predicted the apparent viscosity with correlation coefficient (r), standard error of prediction (SEP), and bias of 0.974, 8.6 cP, and -0.4 cP, respectively. The ratio of the SEP to the standard deviation (RPD) and the ratio of the SEP to the range (RER) for the prediction were 4.4 and 16.7, respectively. Therefore, the model can be used for measurement of the apparent viscosity of field latex and concentrated latex in quality assurance and process control in the factory.
Xu, Qing-Fang; Han, Jian-Guo; Yu, Zhu; Yue, Wen-Bin
2010-05-01
The near infrared reflectance spectroscopy technique (NIRS) has been explored at many fields such as agriculture, food, chemical, medicine, and so on, due to its rapid, effective, non-destructive, and on-line characteristics. Fungi invasion in forage materials during processing and storage would generate mycotoxins, which were harmful for people and animal through food chains. The determination of mycotoxins included the overelaborated pretreatments such as milling, extracting, chromatography and subsequent process such as enzyme linked immunosorbent assay, high performance liquid chromatography, and thin layer chromatography. The authors hope that high precision and low detection limit spectrum instrument, and software technology and calibration model of mycotoxins determination, will fast measure accurately the quality and quantity of mycotoxins, which will provide basis for reasonable process and utilization of forage and promote the application of NIRS in the safety livestock product.
Kos, Gregor; Lohninger, Hans; Mizaikoff, Boris; Krska, Rudolf
2007-07-01
A sample preparation procedure for the determination of deoxynivalenol (DON) using attenuated total reflection mid-infrared spectroscopy is presented. Repeatable spectra were obtained from samples featuring a narrow particle size distribution. Samples were ground with a centrifugal mill and analysed with an analytical sieve shaker. Particle sizes of <100, 100-250, 250-500, 500-710 and 710-1000 microm were obtained. Repeatability, classification and quantification abilities for DON were compared with non-sieved samples. The 100-250 microm fraction showed the best repeatability. The relative standard deviation of spectral measurements improved from 20 to 4.4% and 100% of sieved samples were correctly classified compared with 79% of non-sieved samples. The DON level in analysed fractions was a good estimate of overall toxin content.
Baratieri, Sabrina C; Barbosa, Juliana M; Freitas, Matheus P; Martins, José A
2006-01-23
A multivariate method of analysis of nystatin and metronidazole in a semi-solid matrix, based on diffuse reflectance NIR measurements and partial least squares regression, is reported. The product, a vaginal cream used in the antifungal and antibacterial treatment, is usually, quantitatively analyzed through microbiological tests (nystatin) and HPLC technique (metronidazole), according to pharmacopeial procedures. However, near infrared spectroscopy has demonstrated to be a valuable tool for content determination, given the rapidity and scope of the method. In the present study, it was successfully applied in the prediction of nystatin (even in low concentrations, ca. 0.3-0.4%, w/w, which is around 100,000 IU/5g) and metronidazole contents, as demonstrated by some figures of merit, namely linearity, precision (mean and repeatability) and accuracy.
NASA Technical Reports Server (NTRS)
Lindner, Bernhard Lee
1992-01-01
Research activities to date are discussed. Selected Mariner 9 UV spectra were obtained. Radiative transfer models were updated and then exercised to simulate spectra. Simulated and observed spectra compare favorably. It is noted that large amounts of ozone are currently not retrieved with reflectance spectroscopy, raising large doubts about earlier published ozone abundances. As these published abundances have been used as a benchmark for all theoretical photochemical models of Mars, this deserves further exploration. Three manuscripts were published, and one is in review. Papers were presented and published at three conferences, and are planned for five more conferences in the next six months. The research plan for the next reporting period is discussed and involves continuing studies of reflectance spectroscopy, further examination of Mariner 9 data, and climate change studies of ozone.
Diffuse Reflectance Spectroscopy and Colorimetry as a Diagnostic Tool for Acanthosis Nigricans
NASA Astrophysics Data System (ADS)
Pattamadilok, Bensachee; Devpura, Suneetha; Syed, Zain U.; Vemulapalli, Pranita; Henderson, Marsha; Rehse, Steven J.; Hamzavi, Iltefat; Mahmoud, Bassel H.; Lim, Henry W.; Naik, Ratna
2011-03-01
The purpose of this study was to quantify skin color changes due to Acanthosis Nigricans, a disorder common among prediabetic and obese individuals. The non-invasive optical technique diffuse reflectance spectroscopy (DRS) was used to determine skin melanin, oxyhemoglobin and deoxyhemoglobin content through the measured absorption spectrum. Colorimetery was used to measure skin color based on the standard Tristimulus values (L*, a*, and b*). Data was obtained from eight patients, spanning eight months of treatment. Measurements were obtained from lesion tissue on the neck and healthy skin was used as a control. L*, a* and b* values showed significant differences between lesion and normal controls, whereas melanin was the only parameter which showed statistical significant differences in DRS measurements. Future work will use more sensitive chemometric methods to increase diagnostic accuracy based on the raw spectra of the DRS.
Surface inspection using FTIR spectroscopy
NASA Technical Reports Server (NTRS)
Powell, G. L.; Smyrl, N. R.; Williams, D. M.; Meyers, H. M., III; Barber, T. E.; Marrero-Rivera, M.
1995-01-01
The use of reflectance Fourier transform infrared (FTIR) spectroscopy as a tool for surface inspection is described. Laboratory instruments and portable instruments can support remote sensing probes that can map chemical contaminants on surfaces with detection limits under the best of conditions in the sub-nanometer range, i.e.. near absolute cleanliness, excellent performance in the sub-micrometer range, and useful performance for films tens of microns thick. Examples of discovering and quantifying contamination such as mineral oils and greases, vegetable oils, and silicone oils on aluminum foil, galvanized sheet steel, smooth aluminum tubing, and sandblasted 7075 aluminum alloy and D6AC steel. The ability to map in time and space the distribution of oil stains on metals is demonstrated. Techniques associated with quantitatively applying oils to metals, subsequently verifying the application, and non-linear relationships between reflectance and the quantity oil are described.
Analysis of silage composition by near-infrared reflectance spectroscopy
NASA Astrophysics Data System (ADS)
Reeves, James B., III; Blosser, Timothy H.; Colenbrander, V. F.
1991-02-01
Two studies were performed to investigate the feasibility of using near infrared reflectance spectroscopy (NIRS) with undried silages. In the first study silages were analyzed for major components (e. g. dry matter crude protein and other forms of nitrogen fiber and in vitro digestible dry matter) and short chain fatty acids (SCFA). NIRS was found to operate satisfactorily except for some forms of nitrogen and SCFA. In study two various methods of grinding spectral regions and sample presentation were examined. Undried Wiley ground samples in a rectangular cell gave the best overall results for non-dry ice undried grinds with wavelengths between 1100 and 2498 nm. Silages scanned after drying however produced the best results. Intact samples did not perform as well as ground samples and wavelengths below 1100 nm were of little use. 2 .
NASA Astrophysics Data System (ADS)
Zude, Manuela; Spinelli, Lorenzo; Dosche, Carsten; Torricelli, Alessandro
2009-08-01
In sweet cherry (Prunus avium), the red pigmentation is correlated with the fruit maturity stage and can be measured by non-invasive spectroscopy. In the present study, the influence of varying fruit scattering coefficients on the fruit remittance spectrum (cw) were corrected with the effective pathlength and refractive index in the fruit tissue obtained with distribution of time-of-flight (DTOF) readings and total internal reflection fluorescence (TIRF) analysis, respectively. The approach was validated on fruits providing variation in the scattering coefficient outside the calibration sample set. In the validation, the measuring uncertainty when non-invasively analyzing fruits with cw method in comparison with combined application of cw, DTOF, and TIRF measurements showed an increase in r2 up to 22.7 % with, however, high errors in all approaches.
Plasticity of Micrometer-Scale Single-Crystals in Compression: A Critical Review (PREPRINT)
2008-10-01
annealing, FIB milling followed by low‐energy Ar+ milling, and samples that were grown via electrodeposition followed by annealing (which produced...the three different FIB‐based processing routes had similar values, while the electrodeposited microsamples were stronger on average but showed...with grain‐size strengthening (n = 0.5) or surface‐controlled nucleation (n = 1), for example. Note that the value of n in Eq. 1 is dependent on the
Homogamy and Intermarriage of Japanese and Japanese Americans With Whites Surrounding World War II
Ono, Hiromi; Berg, Justin
2010-01-01
Although some sociologists have suggested that Japanese Americans quickly assimilated into mainstream America, scholars of Japanese America have highlighted the heightened exclusion that the group experienced. This study tracked historical shifts in the exclusion level of Japanese and Japanese Americans in the United States surrounding World War II with homogamy and intermarriage with Whites for the prewar (1930–1940) and resettlement (1946–1966) marriage cohorts. The authors applied log-linear models to census microsamples (N = 1,590,416) to estimate the odds ratios of homogamy versus intermarriage. The unadjusted odds ratios of Japanese Americans declined between cohorts and appeared to be consistent with the assimilation hypothesis. Once compositional influences and educational pairing patterns were adjusted, however, the odds ratios increased and supported the heightened exclusion hypothesis. PMID:21116449
Real-time soil sensing based on fiber optics and spectroscopy
NASA Astrophysics Data System (ADS)
Li, Minzan
2005-08-01
Using NIR spectroscopic techniques, correlation analysis and regression analysis for soil parameter estimation was conducted with raw soil samples collected in a cornfield and a forage field. Soil parameters analyzed were soil moisture, soil organic matter, nitrate nitrogen, soil electrical conductivity and pH. Results showed that all soil parameters could be evaluated by NIR spectral reflectance. For soil moisture, a linear regression model was available at low moisture contents below 30 % db, while an exponential model can be used in a wide range of moisture content up to 100 % db. Nitrate nitrogen estimation required a multi-spectral exponential model and electrical conductivity could be evaluated by a single spectral regression. According to the result above mentioned, a real time soil sensor system based on fiber optics and spectroscopy was developed. The sensor system was composed of a soil subsoiler with four optical fiber probes, a spectrometer, and a control unit. Two optical fiber probes were used for illumination and the other two optical fiber probes for collecting soil reflectance from visible to NIR wavebands at depths around 30 cm. The spectrometer was used to obtain the spectra of reflected lights. The control unit consisted of a data logging device, a personal computer, and a pulse generator. The experiment showed that clear photo-spectral reflectance was obtained from the underground soil. The soil reflectance was equal to that obtained by the desktop spectrophotometer in laboratory tests. Using the spectral reflectance, the soil parameters, such as soil moisture, pH, EC and SOM, were evaluated.
On the prediction of threshold friction velocity of wind erosion using soil reflectance spectroscopy
NASA Astrophysics Data System (ADS)
Li, Junran; Flagg, Cody; Okin, Gregory S.; Painter, Thomas H.; Dintwe, Kebonye; Belnap, Jayne
2015-12-01
Current approaches to estimate threshold friction velocity (TFV) of soil particle movement, including both experimental and empirical methods, suffer from various disadvantages, and they are particularly not effective to estimate TFVs at regional to global scales. Reflectance spectroscopy has been widely used to obtain TFV-related soil properties (e.g., moisture, texture, crust, etc.), however, no studies have attempted to directly relate soil TFV to their spectral reflectance. The objective of this study was to investigate the relationship between soil TFV and soil reflectance in the visible and near infrared (VIS-NIR, 350-2500 nm) spectral region, and to identify the best range of wavelengths or combinations of wavelengths to predict TFV. Threshold friction velocity of 31 soils, along with their reflectance spectra and texture were measured in the Mojave Desert, California and Moab, Utah. A correlation analysis between TFV and soil reflectance identified a number of isolated, narrow spectral domains that largely fell into two spectral regions, the VIS area (400-700 nm) and the short-wavelength infrared (SWIR) area (1100-2500 nm). A partial least squares regression analysis (PLSR) confirmed the significant bands that were identified by correlation analysis. The PLSR further identified the strong relationship between the first-difference transformation and TFV at several narrow regions around 1400, 1900, and 2200 nm. The use of PLSR allowed us to identify a total of 17 key wavelengths in the investigated spectrum range, which may be used as the optimal spectral settings for estimating TFV in the laboratory and field, or mapping of TFV using airborne/satellite sensors.
Reynolds, Richard L.; Goldstein, Harland L.; Moskowitz, Bruce M.; Bryant, Ann C.; Skiles, S. McKenzie; Kokaly, Raymond F.; Flagg, Cody B.; Yauk, Kimberly; Berquó, Thelma S.; Breit, George N.; Ketterer, Michael; Fernandez, Daniel; Miller, Mark E.; Painter, Thomas H.
2014-01-01
Dust layers deposited to snow cover of the Wasatch Range (northern Utah) in 2009 and 2010 provide rare samples to determine the relations between their compositions and radiative properties. These studies are required to comprehend and model how such dust-on-snow (DOS) layers affect rates of snow melt through changes in the albedo of snow surfaces. We evaluated several constituents as potential contributors to the absorption of solar radiation indicated by values of absolute reflectance determined from bi-conical reflectance spectroscopy. Ferric oxide minerals and carbonaceous matter appear to be the primary influences on lowering snow-cover albedo. Techniques of reflectance and Mössbauer spectroscopy as well as rock magnetism provide information about the types, amounts, and grain sizes of ferric oxide minerals. Relatively high amounts of ferric oxide, indicated by hard isothermal remanent magnetization (HIRM), are associated with relatively low average reflectance (<0.25) across the visible wavelengths of the electromagnetic spectrum. Mössbauer spectroscopy indicates roughly equal amounts of hematite and goethite, representing about 35% of the total Fe-bearing phases. Nevertheless, goethite (α-FeOOH) is the dominant ferric oxide found by reflectance spectroscopy and thus appears to be the main iron oxide control on absorption of solar radiation. At least some goethite occurs as nano-phase grain coatings less than about 50 nm thick. Relatively high amounts of organic carbon, indicating as much as about 10% organic matter, are also associated with lower reflectance values. The organic matter, although not fully characterized by type, correlates strongly with metals (e.g., Cu, Pb, As, Cd, Mo, Zn) derived from distal urban and industrial settings, probably including mining and smelting sites. This relation suggests anthropogenic sources for at least some of the carbonaceous matter, such as emissions from transportation and industrial activities. The composition of the DOS samples can be compared with sediments in a likely dust-source setting at the Milford Flat Fire (MFF) area about 225 km southwest of Salt Lake City. The MFF area represents geologically and physiographically similar and widespread dust sources west-southwest of the Wasatch Range and heavily populated Wasatch Front. The DOS layers and MFF sediments are similar in some textural, chemical, and magnetic properties, as well as in the common presence of goethite, hematite, magnetite-bearing basalt fragments, quartz, plagioclase, illite, and kaolinite. Textural and some chemical differences among these deposits can be explained by atmospheric sorting as well as by inputs from other settings, such as salt-crusted playas and contaminant sources.
Optical diffuse reflectance accessory for measurements of skin tissue by near-infrared spectroscopy
NASA Astrophysics Data System (ADS)
Marbach, R.; Heise, H. M.
1995-02-01
An optimized accessory for measuring the diffuse reflectance spectra of human skin tissue in the near-infrared spectral range is presented. The device includes an on-axis ellipsoidal collecting mirror with efficient illumination optics for small sampling areas of bulky body specimens. The optical design is supported by the results of a Monte Carlo simulation study of the reflectance characteristics of skin tissue. Because the results evolved from efforts to measure blood glucose noninvasively, the main emphasis is placed on the long-wavelength near-infrared range where sufficient penetration depth for radiation into tissue is still available. The accessory is applied for in vivo diffuse reflectance measurements.
Theory of fiber-optic, evanescent-wave spectroscopy and sensors
NASA Astrophysics Data System (ADS)
Messica, A.; Greenstein, A.; Katzir, A.
1996-05-01
A general theory for fiber-optic, evanescent-wave spectroscopy and sensors is presented for straight, uncladded, step-index, multimode fibers. A three-dimensional model is formulated within the framework of geometric optics. The model includes various launching conditions, input and output end-face Fresnel transmission losses, multiple Fresnel reflections, bulk absorption, and evanescent-wave absorption. An evanescent-wave sensor response is analyzed as a function of externally controlled parameters such as coupling angle, f number, fiber length, and diameter. Conclusions are drawn for several experimental apparatuses.
Three-Dimensional Intercalated Porous Graphene on Si(111)
NASA Astrophysics Data System (ADS)
Pham, Trung T.; Sporken, Robert
2018-02-01
Three-dimensional intercalated porous graphene has been formed on Si(111) by electron beam evaporation under appropriate conditions and its structural and electronic properties investigated in detail by reflection high-energy electron diffraction, x-ray photoemission spectroscopy, Raman spectroscopy, high-resolution scanning electron microscopy, atomic force microscopy, and scanning tunneling microscopy. The results show that the crystalline quality of the porous graphene depended not only on the substrate temperature but also on the SiC layer thickness during carbon atom deposition.
CdZnO coated film: A material for photovoltaic applications
NASA Astrophysics Data System (ADS)
Zargar, R. A.; Bhat, M. A.; Reshi, H. A.; Khan, S. D.
2018-06-01
The present study reports structural and optical parameters of wide band gap oxide thick film prepared by screen-printing followed by sintering route. Characterization of the samples was carried out with UV-spectroscopy, XRD, SEM, and Photoluminous study. The XRD and SEM studies reveal that the film deposited is polycrystalline, double phase, and porous with unsymmetrical grain distributions. Optical diffused reflection spectroscopy and Pl measurements give optical band gap of 2.87 eV and near band edge emission at 430 nm.
Infrared Spectroscopy of Blood for Disease Identification
NASA Astrophysics Data System (ADS)
Pichardo, J. L.; Huerta-Franco, R.; Álvarez, R. R.; Bernal, J.; Gutiérrez-Juárez, G.; Palomares-Anda, P.
2003-09-01
Total reflectance attenuated infrared Fourier transform spectroscopy was used to analyze blood samples. Plasma and red blood cells were separated by centrifugation. The spectra were recorded from 200 to 4000 cm-1 under the same conditions for all samples. Samples of healthy donors were compared with those patients with different diseases (polycythemia and high blood pressure). Patients were under medical control at the time of the study. However, the preliminary results reveal that blood samples from healthy subjects had different infrared spectra compared to the non healthy patients.
Acceleration of domain wall movement by photoirradiation in perovskite-type cobaltite
NASA Astrophysics Data System (ADS)
Okimoto, Y.; Kurashima, M.; Seko, K.; Ishikawa, T.; Onda, K.; Koshihara, S.; Kyomen, T.; Itoh, M.
2011-04-01
Femtosecond reflection spectroscopy was performed on a perovskite-type cobalt oxide, namely, Pr0.5Ca0.5CoO3, that undergoes a photoinduced spin-state transition. After photoirradiation at 30 K, the time profile of the reflectance change shows a broad peak reflecting the propagation of the photodomain (about 60 Co sites per one photon). Analysis of the peak position indicates the sudden increase of the velocity of the propagation with increasing the excitation intensity. Such acceleration with increase in fluence originates from an abrupt sound velocity change driven by a cooperative photoinduced structural transition.
Excitonic and band-band transitions of Cu2ZnSiS4 determined from reflectivity spectra
NASA Astrophysics Data System (ADS)
Guc, M.; Levcenko, S.; Dermenji, L.; Gurieva, G.; Schorr, S.; Syrbu, N. N.; Arushanov, E.
2014-07-01
Exciton spectra of Cu2ZnSiS4 single crystals are investigated by reflection spectroscopy at 10 and 300 K for light polarized perpendicular (E⊥c) and parallel (E∥c) to the optical axis. The parameters of the excitons and dielectric constant are determined. The free carriers effective masses have been estimated. The room temperature reflectivity spectra at photon energies higher than the fundamental band gap in the polarization Е⊥с and E∥с were measured and related to the electronic band structure of Cu2ZnSiS4.
NASA Technical Reports Server (NTRS)
Orenberg, James; Handy, Jonathan
1992-01-01
The diffuse reflectance spectra of Hawaiian palagonite mixtures with an Fe-rich montmorillonite have prompted their present use as spectral analogs of the Martian surface. Like the Mars spectrum and unlike clays, the 2.2-micron reflectance spectrum absorption band is not present in the palagonite sample; neither is the 2.2-micron Al-OH clay lattice band seen in palagonite-montmorillonite mixtures, where the latter component remains below 15 wt pct. Fe-rich montmorillonite clay may therefore be present in Mars, in combination with palagonite, while remaining undetected in remotely sensed spectra.
Zhao, Wei; Li, Cheng; Wang, Aijian; Lv, Cuncai; Zhu, Weihua; Dou, Shengping; Wang, Qian; Zhong, Qin
2017-11-01
Polyaniline (PANI)-decorated Bi 2 MoO 6 nanosheets (BMO/PANI) were prepared by a facile solvothermal method. Different characterization techniques, including X-ray powder diffraction, scanning electron microscopy, transmission electron microscopy, Raman spectroscopy, Fourier transform infrared spectroscopy, X-ray photoelectron spectroscopy, diffuse reflectance ultraviolet-visible spectroscopy, photoluminescence spectroscopy, electrochemical impedance spectroscopy, photocurrent spectroscopy, and nanosecond time-resolved emission studies, have been employed to investigate the structure, optical and electrical properties of the BMO/PANI composites. The wide absorption of the samples in the visible light region makes them suitable for nonlinear transmission and photocatalytic activity studies. The associated photocatalytic activity and optical nonlinearities for the BMO/PANI composites are shown to be dependent on the PANI loadings. The rational mechanisms responsible for deteriorating pollutants and improving optical nonlinearities were also proposed, which could be mainly attributed to the efficient interfacial charge transfer and the interfacial electronic interactions between PANI and Bi 2 MoO 6 . The photoluminescence spectroscopy, electrochemical impedance spectroscopy, and photocurrent spectroscopy studies confirmed that the interface charge separation efficiency was greatly improved by coupling Bi 2 MoO 6 with PANI. The tuning of photocatalysis and nonlinear optical behaviors with variation in the content of PANI provides an easy way to attain tunable properties, which are exceedingly required in optoelectronics applications.
NASA Technical Reports Server (NTRS)
Janice, Bishop; Banin, A.; Mancinelli, R. L.; Klovstad, M. R.; DeVincenzi, Donald L. (Technical Monitor)
2001-01-01
Nitrogen is an essential element for life. It is the only element among the six major biogenic elements, C, O, S, O, P, H, whose presence in the Martian soil has not been positively and directly established. We describe here a study assessing the ability to detect NH4 in soils by two methods: differential thermal analysis (DTA) and infrared (IR) reflectance spectroscopy. Four standard clay minerals (kaolinite, montmorillonite, illite and attapulgite) and an altered tephra sample from Mauna Kea were treated with NH4 in this study. Samples of the NH4-treated and leached clays were analyzed by DTA and infrared (IR) reflectance spectroscopy to quantify the delectability of soluble and sorbed/fixed NH4. An exotherm at 270-280 C was clearly detected in the DTA curves of NH4-treated (non-leached) samples. This feature is assigned to the thermal decomposition reaction of NH4. Spectral bands observed at 1.56, 2.05, 2.12, 3.06, 3.3, 3.5, 5.7 and 7.0 microns in the reflectance spectra of NH4-treated and leached samples are assigned to the sorbed/fixed ammonium in the clays. The montmorillonite has shown the most intense absorbance due to fixed ammonium among the leached samples in this study, as a result of its high cation sorption capacity. It is concluded that the presence of sorbed or fixed NH4 in clays may be detected by infrared (IR) reflectance or emission spectroscopy. Distinction between soluble and sorbed NH4 may be achieved through the presence or absence of several spectral features assigned to the sorbed NH4 moietyi and, specifically, by use of the 4.2 micrometer feature assigned to solution NH4. Thermal analyses furnish supporting evidence of ammonia in our study through detection of N released at temperatures of 270-330 C. Based on these results it is estimated that IR spectra measured from a rover should be able to detect ammonia if present above 20 mg NH4/g sample in the surface layers. Orbital IR spectra and thermal analyses measured on a rover may be able to detect ammonia in soils as well but at higher abundances. The spectral features at 3.06 and 7.0 microns due to bound NH4 in clays and altered Hawaiian tephra appear to be the most promising for detection by orbital spectrometers. If N species are present on Mars the sedimentary deposits may be the best regions to look for them.
2012-05-01
field-programmable gate array (FPGA) uses digital signal processing (DSP) algorithms to decode echo-location information from the backscattered signal ...characterizing and understanding of the physical properties of the BST and PZT thin films. Using microwave reflection spectroscopy, the complex...acoustic data, , would be encoded in the reflected MW signal by means of phase modulation (PM). By using high-Q resonators as the reactive
NASA Astrophysics Data System (ADS)
Kalashnyk, N.; Perry, D. L.; Massuyeau, F.; Faulques, E.
2017-12-01
Several optical microprobe experiments of the anhydrous uranium carbonate—rutherfordine—are presented in this work and compared to periodic density functional theory results. Rutherfordine is the simplest uranyl carbonate and constitutes an ideal model system for the study of the rich uranium carbonate family relevant for environmental sustainability. Micro-Raman, micro-reflectance, and micro-photoluminescence (PL) spectroscopy studies have been carried out in situ on native, micrometer-sized crystals. The sensitivity of these techniques is sufficient to analyze minute amounts of samples in natural environments without using x-ray analysis. In addition, very intense micro-PL and micro-reflectance spectra that were not reported before add new results on the ground and excited states of this mineral. The optical gap value determined experimentally is found at about 2.6-2.8 eV. Optimized geometry, band structure, and phonon spectra have been calculated. The main vibrational lines are identified and predicted by this theoretical study. This work is pertinent for optical spectroscopy, for identification of uranyl species in various environmental settings, and for nuclear forensic analysis.
Anodic electrodeposition of NiTSPP from aqueous basic media.
Pérez-Morales, Marta; Muñoz, Eulogia; Martín-Romero, María T; Camacho, Luis
2005-06-07
The oxidative electrodeposition of NiTSPP (tetrakis(4-sulfonatophenyl) Ni porphyrin) on ITO electrode from 0.1 M NaOH aqueous solution has been studied, and UV-visible and reflection FTIR spectroscopies have been used to analyze the composition of such film. By use of UV-vis spectroscopy, small absorbance of the film and an almost nulling effect on the Soret band of the porphyrin along the Ni(III)/Ni(II) redox process were observed. The reflection FTIR spectroscopy detected the presence of Ni-OH groups in the reduced film and as well the state of the porphyrin molecules as radical cation. Moreover, the porphyrin has been quantified by means of the area of the vibration bands assigned to the sulfonate groups by using as reference a Langmuir-Blodgett film containing a known surface concentration of NiTSPP. These results lead us propose the formation of a conductor salt by electrocrystallization, with stoichiometries TSPP/Ni(II)(OH)2 and TSPP/Ni(III)OOH, for its reduced and oxidized forms, respectively. In these two forms, the porphyrin rings will be present as radical cation, which may be stabilized through its dimerization or polymerization.
Zhang, Shule; Zhong, Qin; Shen, Yuge; Zhu, Li; Ding, Jie
2015-06-15
This study aimed at investigating the reason of high catalytic activity for CeO2-WO3/TiO2 catalyst from the aspects of WO3 interaction with other species and the NO oxidation process. Analysis by X-ray diffractometry, photoluminescence spectra, diffuse reflectance UV-visible, X-ray photoelectron spectroscopy, density functional theory calculations, electron paramagnetic resonance spectroscopy, temperature-programmed-desorption of NO and in situ diffuse reflectance infrared transform spectroscopy showed that WO3 could interact with CeO2 to improve the electron gaining capability of CeO2 species. In addition, WO3 species acted as electron donating groups to transfer the electrons to CeO2 species. The two aspects enhanced the formation of reduced CeO2 species to improve the formation of superoxide ions. Furthermore, the Ce species were the active sites for the NO adsorption and the superoxide ions over the catalyst needed oxidizing the adsorbed NO to improve the NO oxidation. This process was responsible for the high catalytic activity of CeO2-WO3/TiO2 catalyst. Copyright © 2015 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Weger, Lukas; Hoffmann-Jacobsen, Kerstin
2017-09-01
Fluorescence correlation spectroscopy (FCS) measures fluctuations in a (sub-)femtoliter volume to analyze the diffusive behavior of fluorescent particles. This highly sensitive method has proven to be useful for the analysis of dynamic biological systems as well as in chemistry, physics, and material sciences. It is routinely performed with commercial fluorescence microscopes, which provide a confined observation volume by the confocal technique. The evanescent wave of total internal reflectance (TIR) is used in home-built systems to permit a surface sensitive FCS analysis. We present a combined confocal and TIR-FCS setup which uses economic low-power pulsed diode lasers for excitation. Excitation and detection are coupled to time-correlated photon counting hardware. This allows simultaneous fluorescence lifetime and FCS measurements in a surface-sensitive mode. Moreover, the setup supports fluorescence lifetime correlation spectroscopy at surfaces. The excitation can be easily switched between TIR and epi-illumination to compare the surface properties with those in liquid bulk. The capabilities of the presented setup are demonstrated by measuring the diffusion coefficients of a free dye molecule, a labeled polyethylene glycol, and a fluorescent nanoparticle in confocal as well as in TIR-FCS.
Tailoring optical properties of TiO2-Cr co-sputtered films using swift heavy ions
NASA Astrophysics Data System (ADS)
Gupta, Ratnesh; Sen, Sagar; Phase, D. M.; Avasthi, D. K.; Gupta, Ajay
2018-05-01
Effect of 100 MeV Au7+ ion irradiation on structure and optical properties of Cr-doped TiO2 films has been studied using X-ray photoelectron spectroscopy, soft X-ray absorption spectroscopy, UV-Visible spectroscopy, X-ray reflectivity, and atomic force microscopy. X-ray reflectivity measurement implied that film thickness reduces as a function of ion fluence while surface roughness increases. The variation in surface roughness is well correlated with AFM results. Ion irradiation decreases the band gap energy of the film. Swift heavy ion irradiation enhances the oxygen vacancies in the film, and the extra electrons in the vacancies act as donor-like states. In valence band spectrum, there is a shift in the Ti3d peak towards lower energies and the shift is equivalent to the band gap energy obtained from UV spectrum. Evidence for band bending is also provided by the corresponding Ti XPS peak which exhibits a shift towards lower energy due to the downward band bending. X-ray absorption studies on O Kand Cr L3,2 edges clearly indicate that swift heavy ion irradiation induces formation of Cr-clusters in TiO2 matrix.
Khurana, Harpreet Kaur; Cho, Il Kyu; Shim, Jae Yong; Li, Qing X; Jun, Soojin
2008-02-13
Aspartame is a low-calorie sweetener commonly used in soft drinks; however, the maximum usage dose is limited by the U.S. Food and Drug Administration. Fourier transform infrared (FTIR) spectroscopy with attenuated total reflectance sampling accessory and partial least-squares regression (PLS) was used for rapid determination of aspartame in soft drinks. On the basis of spectral characterization, the highest R2 value, and lowest PRESS value, the spectral region between 1600 and 1900 cm(-1) was selected for quantitative estimation of aspartame. The potential of FTIR spectroscopy for aspartame quantification was examined and validated by the conventional HPLC method. Using the FTIR method, aspartame contents in four selected carbonated diet soft drinks were found to average from 0.43 to 0.50 mg/mL with prediction errors ranging from 2.4 to 5.7% when compared with HPLC measurements. The developed method also showed a high degree of accuracy because real samples were used for calibration, thus minimizing potential interference errors. The FTIR method developed can be suitably used for routine quality control analysis of aspartame in the beverage-manufacturing sector.
Kumar, Raj; Sharma, Vishal
2017-03-15
The present research is focused on the analysis of writing inks using destructive UV-Vis spectroscopy (dissolution of ink by the solvent) and non-destructive diffuse reflectance UV-Vis-NIR spectroscopy along with Chemometrics. Fifty seven samples of blue ballpoint pen inks were analyzed under optimum conditions to determine the differences in spectral features of inks among same and different manufacturers. Normalization was performed on the spectroscopic data before chemometric analysis. Principal Component Analysis (PCA) and K-mean cluster analysis were used on the data to ascertain whether the blue ballpoint pen inks could be differentiated by their UV-Vis/UV-Vis NIR spectra. The discriminating power is calculated by qualitative analysis by the visual comparison of the spectra (absorbance peaks), produced by the destructive and non-destructive methods. In the latter two methods, the pairwise comparison is made by incorporating the clustering method. It is found that chemometric method provides better discriminating power (98.72% and 99.46%, in destructive and non-destructive, respectively) in comparison to the qualitative analysis (69.67%). Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Huang, Huachuan; Liu, Qiao; Zhu, Liguo; Li, Zeren
2018-01-01
The hydration of biomolecules is closely related to the dynamic process of their functional expression, therefore, characterizing hydration phenomena is a subject of keen interest. However, direct measurements on the global hydration state of biomolecules couldn't have been acquired using traditional techniques such as thermodynamics, ultrasound, microwave spectroscopy or viscosity, etc. In order to realize global hydration characterization of amino acid such as L-threonine, terahertz time-domain attenuated total reflectance spectroscopy (THz-TDS-ATR) was adopted in this paper. By measuring the complex permittivity of L-threonine solutions with various concentrations in the THz region, the hydration state and its concentration dependence were obtained, indicating that the number of hydrous water decreased with the increase of concentration. The hydration number was evaluated to be 17.8 when the molar concentration of L-threonine was 0.34 mol/L, and dropped to 13.2 when the molar concentration increased to 0.84 mol/L, when global hydration was taken into account. According to the proposed direct measurements, it is believed that the THz-TDS-ATR technique is a powerful tool for studying the picosecond molecular dynamics of amino acid solutions.
NASA Astrophysics Data System (ADS)
Munirathnam, K.; Dillip, G. R.; Chaurasia, Shivanand; Joo, S. W.; Deva Prasad Raju, B.; John Sushma, N.
2016-08-01
Near white-light emitting LiNa3P2O7:Dy3+ phosphors were prepared by a conventional solid-state reaction method. The orthorhombic crystal structure of the phosphors was confirmed using X-ray diffraction (XRD), and the valence states of the surface elements were determined from the binding energies of Li 1s, O 1s, Na 1s, P 2p, and Dy 3d by X-ray photoelectron spectroscopy (XPS). Attenuated total reflectance (ATR) - Fourier transform infrared (FT-IR) spectroscopy was employed to identify the pyrophosphate groups in the phosphors. Diffuse reflectance spectra (DRS) show the absorption bands of the Dy3+ ions in the host material. Intense blue (481 nm) and yellow (575 nm) emissions were obtained at an excitation wavelength of 351 nm and are attributed to the 4F9/2 → 6H15/2 and 4F9/2 → 6H13/2 transitions of Dy3+ ions, respectively. The combination of these two intense bands generates light emission in the near-white region of the chromaticity diagram.
Integrating sphere based reflectance measurements for small-area semiconductor samples
NASA Astrophysics Data System (ADS)
Saylan, S.; Howells, C. T.; Dahlem, M. S.
2018-05-01
This article describes a method that enables reflectance spectroscopy of small semiconductor samples using an integrating sphere, without the use of additional optical elements. We employed an inexpensive sample holder to measure the reflectance of different samples through 2-, 3-, and 4.5-mm-diameter apertures and applied a mathematical formulation to remove the bias from the measured spectra caused by illumination of the holder. Using the proposed method, the reflectance of samples fabricated using expensive or rare materials and/or low-throughput processes can be measured. It can also be incorporated to infer the internal quantum efficiency of small-area, research-level solar cells. Moreover, small samples that reflect light at large angles and develop scattering may also be measured reliably, by virtue of an integrating sphere insensitive to directionalities.
Nickels, Tara M; Ingram, Audrey L; Maraoulaite, Dalia K; White, Robert L
2015-07-01
Molecular interactions between benzoic acid and cations and water contained in montmorillonite clay interlayer spaces are characterized by using variable temperature diffuse reflection infrared Fourier transform spectroscopy (VT-DRIFTS). Using sample perturbation and difference spectroscopy, infrared spectral changes resulting from removal of interlayer water and associated changes in local benzoic acid environments are identified. Difference spectra features can be correlated with changes in specific molecular vibrations that are characteristic of benzoic acid molecular orientation. Results suggest that the carboxylic acid functionality of benzoic acid interacts with interlayer cations through a bridging water molecule and that this interaction is affected by the nature of the cation present in the clay interlayer space.
Competitive Self-Assembly Manifests Supramolecular Darwinism in Soft-Oxometalates
NASA Astrophysics Data System (ADS)
Das, Santu; Kumar, Saurabh; Mallick, Apabrita; Roy, Soumyajit
2015-09-01
Topological transformation manifested in inorganic materials shows manifold possibilities. In our present work, we show a clear topological transformation in a soft-oxometalate (SOM) system which was formed from its polyoxometalate (POM) precursor [PMo12@Mo72Fe30]. This topological transformation was observed due to time dependent competitive self-assembly of two different length scale soft-oxometalate moieties formed from this two-component host-guest reaction. We characterized different morphologies by scanning electron microscopy, electron dispersive scattering spectroscopy, dynamic light scattering, horizontal attenuated total reflection-infrared spectroscopy and Raman spectroscopy. The predominant structure is selected by its size in a sort of supramolecular Darwinian competition in this process and is described here.
Huang, Zhiwei; Teh, Seng Khoon; Zheng, Wei; Mo, Jianhua; Lin, Kan; Shao, Xiaozhuo; Ho, Khek Yu; Teh, Ming; Yeoh, Khay Guan
2009-03-15
We report an integrated Raman spectroscopy and trimodal (white-light reflectance, autofluorescence, and narrow-band) imaging techniques for real-time in vivo tissue Raman measurements at endoscopy. A special 1.8 mm endoscopic Raman probe with filtering modules is developed, permitting effective elimination of interference of fluorescence background and silica Raman in fibers while maximizing tissue Raman collections. We demonstrate that high-quality in vivo Raman spectra of upper gastrointestinal tract can be acquired within 1 s or subseconds under the guidance of wide-field endoscopic imaging modalities, greatly facilitating the adoption of Raman spectroscopy into clinical research and practice during routine endoscopic inspections.
Assembly of Ring-Shaped Phosphorus within Carbon Nanotube Nanoreactors.
Zhang, Jinying; Zhao, Dan; Xiao, Dingbin; Ma, Chuansheng; Du, Hongchu; Li, Xin; Zhang, Lihui; Huang, Jialiang; Huang, Hongyang; Jia, Chun-Lin; Tománek, David; Niu, Chunming
2017-02-06
A phosphorus allotrope that has not been observed so far, ring-shaped phosphorus consisting of alternate P 8 and P 2 structural units, has been assembled inside multi-walled carbon nanotube nanoreactors with inner diameters of 5-8 nm by a chemical vapor transport and reaction of red phosphorus at 500 °C. The ring-shaped nanostructures with surrounding graphene walls are stable under ambient conditions. The nanostructures were characterized by high-resolution transmission electron microscopy, scanning transmission electron microscopy, energy-dispersive X-ray spectroscopy, Raman scattering, attenuated total reflectance Fourier transform infrared spectroscopy, and X-ray photoelectron spectroscopy. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Smolin, Sergey Y.
Ultrafast transient absorption and reflectance spectroscopy are foundational techniques for studying photoexcited carrier recombination mechanisms, lifetimes, and charge transfer rates. Because quantifying photoexcited carrier dynamics is central to the intelligent design and improvement of many solid state devices, these transient optical techniques have been applied to a wide range of semiconductors. However, despite their promise, interpretation of transient absorption and reflectance data is not always straightforward and often relies on assumptions of physical processes, especially with respect to the influence of heating. Studying the material space of perovskite oxides, the careful collection, interpretation, and analysis of ultrafast data is presented here as a guide for future research into novel semiconductors. Perovskite oxides are a class of transition metal oxides with the chemical structure ABO3. Although traditionally studied for their diverse physical, electronic, and magnetic properties, perovskite oxides have gained recent research attention as novel candidates for light harvesting applications. Indeed, strong tunable absorption, unique interfacial properties, and vast chemical flexibility make perovskite oxides a promising photoactive material system. However, there is limited research characterizing dynamic optoelectronic properties, such as recombination lifetimes, which are critical to know in the design of any light-harvesting device. In this thesis, ultrafast transient absorption and reflectance spectroscopy was used to understand these dynamic optoelectronic properties in highquality, thin (<50 nm) perovskite oxide films grown by molecular beam epitaxy. Starting with epitaxial LaFeO3 (LFO) grown on (LaAlO 3)0.3(Sr2AlTaO6)0.7 (LSAT), transient absorption spectroscopy reveals two photoinduced absorption features at the band gap of LFO at 2.4 eV and at the higher energy absorption edge at 3.5 eV. Using a combination of temperature-dependent, variable-angle spectroscopic ellipsometry and time-resolved ultrafast optical spectroscopy on a type I heterostructure, we clarify thermal and electronic contributions to spectral transients in LaFeO3. Upon comparison to thermally-derived static spectra of LaFeO3, we find that thermal contributions dominate the transient absorption and reflectance spectra above the band gap. A transient photoinduced absorption feature below the band gap at 1.9 eV is not reproduced in the thermally derived spectra and has significantly longer decay kinetics from the thermallyinduced features; therefore, this long lived photoinduced absorption is likely derived, at least partially, from photoexcited carriers with lifetimes much longer than 3 nanoseconds. LaFeO3 has a wide band gap of 2.4 eV but its absorption can be decreased with chemical substitution of Sr for Fe to make it more suitable for various applications. This type of A-site substitution is a common route to change static optical absorption in perovskite oxides, but there are no systematic studies looking at how A-site substitution changes dynamic optoelectronic properties. To understand the relationship between composition and static and dynamic optical properties we worked with the model system of La1-xSrxFeO 3-delta epitaxial films grown on LSAT, uncovering the effects of A-site cation substitution and oxygen stoichiometry. Variable-angle spectroscopic ellipsometry was used to measure static optical properties, revealing a linear increase in absorption coefficient at 1.25 eV and a red-shifting of the optical absorption edge with increasing Sr fraction. The absorption spectra can be similarly tuned through the introduction of oxygen vacancies, indicating the critical role that nominal Fe valence plays in optical absorption. Dynamic optoelectronic properties were studied with ultrafast transient reflectance spectroscopy with broadband visible (1.6 eV to 4 eV) and near-infrared (0.9 eV to 1.5 eV) probes. The sign of the reflectance change in the near-infrared region in LSFO is indicative of carrier bandfilling of newly created electronic states by photoexcited carriers. Moreover, we find that similar transient spectral trends can be induced with A-site substitution or through oxygen vacancies, which is a surprising result. Probing the near-infrared region reveals similar nanosecond (1-3 ns) photoexcited carrier lifetimes for oxygen deficient and stoichiometric films. These results demonstrate that while the static optical absorption is strongly dependent on nominal Fe valence tuned through cation or anion stoichiometry, oxygen vacancies do not appear to play a significantly detrimental role in long lived recombination kinetics. Although this thesis represents one of the first comprehensive studies using broad band transient absorption and reflectance spectroscopy to study dynamic optoelectronic phenomena in perovskite oxides, it can also serve as a guide for the implementation and interpretation of ultrafast spectroscopy in other material systems. Moreover, the ultrafast work on perovskite oxides indicates that these materials have long nanosecond lifetimes required for light harvesting devices and should be investigated further.
Exploring Space Weathering on Mercury Using Global UV-VIS Reflectance Spectroscopy
NASA Astrophysics Data System (ADS)
Izenberg, N. R.; Denevi, B. W.
2018-05-01
We apply UV analysis methods used on lunar LROC data to Mercury to explore space weathering maturity and possibly evidence of shocked minerals. What says the UV // about shock, maturity // on dear Mercury?
Novel utilisation of a circular multi-reflection cell applied to materials ageing experiments
NASA Astrophysics Data System (ADS)
Knox, D. A.; King, A. K.; McNaghten, E. D.; Brooks, S. J.; Martin, P. A.; Pimblott, S. M.
2015-04-01
We report on the novel utilisation of a circular multi-reflection (CMR) cell applied to materials ageing experiments. This enabled trace gas detection within a narrow interfacial region located between two sample materials and remotely interrogated with near-infrared sources combined with fibre-optic coupling. Tunable diode laser absorption spectroscopy was used to detect water vapour and carbon dioxide at wavelengths near 1,358 and 2,004 nm, respectively, with corresponding detection limits of 7 and 1,139 ppm m Hz-0.5. The minimum detectable absorption was estimated to be 2.82 × 10-3 over a 1-s average. In addition, broadband absorption spectroscopy was carried out for the detection of acetic acid, using a super-luminescent light emitting diode centred around 1,430 nm. The 69 cm measurement pathlength was limited by poor manufacturing tolerances of the spherical CMR mirrors and the consequent difficulty of collecting all the cell output light.
Han, Bing; Hang Hu, Yun
2017-07-28
A novel technique, high temperature high pressure in situ Fourier transform infrared diffuse reflection spectroscopy, was successfully used to investigate the formation and stability of shallow trap states in P25 TiO 2 nanoparticles. Two types of shallow traps (with and without H atoms) were identified. The H-containing shallow trap can be easily generated by heating in H 2 atmosphere. However, the trap is unstable in vacuum at 600 °C. In contrast, the H-free shallow trap, which can be formed by heating in vacuum, is stable even at 600 °C. The energy gaps between shallow trap states and the conduction band are 0.09 eV for H-containing shallow trap and 0.13 eV for H-free shallow trap, indicating that the H-containing shallow trap state is closer to the conduction band than that without H.
Jobst, Johannes; van der Torren, Alexander J H; Krasovskii, Eugene E; Balgley, Jesse; Dean, Cory R; Tromp, Rudolf M; van der Molen, Sense Jan
2016-11-29
High electron mobility is one of graphene's key properties, exploited for applications and fundamental research alike. Highest mobility values are found in heterostructures of graphene and hexagonal boron nitride, which consequently are widely used. However, surprisingly little is known about the interaction between the electronic states of these layered systems. Rather pragmatically, it is assumed that these do not couple significantly. Here we study the unoccupied band structure of graphite, boron nitride and their heterostructures using angle-resolved reflected-electron spectroscopy. We demonstrate that graphene and boron nitride bands do not interact over a wide energy range, despite their very similar dispersions. The method we use can be generally applied to study interactions in van der Waals systems, that is, artificial stacks of layered materials. With this we can quantitatively understand the 'chemistry of layers' by which novel materials are created via electronic coupling between the layers they are composed of.
Tang, Yongjiao; Jing, Nan; Zhang, Pudun
2015-11-01
A series of chlorobutyl rubber/polyamide-12 (CIIR/PA-12) blends compatibilized by different amounts of maleic anhydride (MAH) grafted polypropylene (PP-g-MAH) were investigated by attenuated total reflection Fourier transform infrared spectroscopy (ATR FT-IR) mapping. Multivariate curve resolution (MCR) was used to process the FT-IR images. Both the spectra of pure components in the blends and their concentration distributions in a micro-region were acquired. Our results demonstrated that the blend with 15 parts per hundred rubber PP-g-MAH showed the best miscibility. An amide interphase and an imide interphase were inferred by analyzing the spectra of MCR component 3 of the blends with and without PP-g-MAH, respectively. Correspondingly, two different compatibilizing mechanisms were proposed for these blends.
Optical Reflection Spectroscopy of GEO Objects
NASA Technical Reports Server (NTRS)
Seitzer, Patrick; Cardona, Tammaso; Lederer, Susan M.; Cowardin, Heather; Abercromby, Kira J.; Barker, Edwin S.; Bedard, Donald
2013-01-01
We report on optical reflection spectroscopy of geosynchronous (GEO) objects in the US Space Surveillance Network (SSN) catalog. These observations were obtained using imaging spectrographs on the 6.5-m Magellan telescopes at the Las Campanas Observatory in Chile. Our goal is to determine the composition of these objects by comparing these spectral observations with ground-based laboratory measurements of spacecraft materials. The observations are all low resolution (1 nm after smoothing) obtained through a 5 arcsecond wide slit and using a grism as the dispersing element. The spectral range covered was from 450 nm to 800 nm. All spectra were flux calibrated using observations of standard stars with the exact same instrumental setup. An effort was made to obtain all observations within a limited range of topocentric phase angle, although the solar incident angle is unknown due to the lack of any knowledge of the attitude of the observed surface at the time of observation.
NASA Astrophysics Data System (ADS)
Tseng, Sheng-Hao; Hsu, Chao-Kai; Yu-Yun Lee, Julia; Tzeng, Shih-Yu; Chen, Wan-Rung; Liaw, Yu-Kai
2012-07-01
Collagen is a rich component in skin that provides skin structure integrity; however, its contribution to the absorption and scattering properties of various types of skin has not been extensively studied. We considered the contribution of the collagen to the absorption spectrum of in vivo normal skin and keloids of 12 subjects derived from our diffuse reflectance spectroscopy (DRS) system in the wavelength range from 550 to 860 nm. It was found that the collagen concentration, the hemoglobin oxygen saturation, and the reduced scattering coefficient of keloids were remarkably different from that of normal skin. Our results suggest that our DRS system could assist clinicians in understanding the functional and structural condition of keloid scars. In the future, we will evaluate the accuracy of our system in the keloid diagnosis and investigate the applicability of our system for other skin-collagen-related studies.
Optical fiber spectroscopy measures perfusion of the brain in a murine Alzheimer's disease model
NASA Astrophysics Data System (ADS)
Ahn, Hyung Jin; Strickland, Sidney; Krueger, James; Gareau, Daniel
2014-02-01
Optical fiber spectroscopy is a versatile tool for measuring diffuse reflectance and extracting absorption information that can noninvasively quantify the presence of chromophores such as oxyhemoglobin and deoxy-hemoglobin in tissues. Cerebrovascular abnormalities were widely recognized in Alzheimer's disease (AD) patients. We analyzed blood volume fraction and level of oxygenated hemoglobin in Tg6799 mice, which are transgenic mice expressing five different familial Alzheimer disease-associated mutations in the human amyloid precursor protein and presenilin-1 genes. Diffuse reflectance spectra were iteratively fit as weighted sums of oxy- and deoxy-hemoglobin. Our observations showed slightly hypoxic conditions and significantly increased blood volume in the Alzheimer's mice versus wild type. These results suggest that hyperperfusion of our AD mice may be a compensating mechanism for impaired cerebral vascular function and somehow relevant with early stage of AD patients. Ongoing work focuses on developing a cannula fixture that allows measurement in awake, behaving animals.
High Zn Content Single-phase RS-MgZnO Suitable for Solar-blind Frequency Applications
NASA Astrophysics Data System (ADS)
Liang, H. L.; Mei, Z. X.; Liu, Z. L.; Guo, Y.; Azarov, A. Yu.; Kuznetsov, A. Yu.; Hallen, A.; Du, X. L.
2010-11-01
Single-phase rock-salt MgZnO films with high Zn content were successfully fabricated on the templates of MgO (111)/α-sapphire (0001) by radio-frequency plasma assisted molecular beam epitaxy. The influence of growth temperature on epitaxy of MgZnO alloy films was investigated by the combined studies of crystal structures, compositions, and optical properties. It is found that the incorporation of Zn atoms into the rock-salt MgZnO films is greatly enhanced at low temperature, confirmed by in-situ reflection high-energy electron diffraction observations and ex-situ X-ray diffraction characterization. Zn fraction in the single-phase rock-salt Mg0.53Zn0.47O film was determined by Rutherford backscattering spectrometry. Optical properties of the films were investigated by transmittance spectroscopy and reflectance spectroscopy, both of which demonstrate the solar-blind band gap and its dependence on Zn content.
Allgeyer, Edward S; Sterling, Sarah M; Gunewardene, Mudalige S; Hess, Samuel T; Neivandt, David J; Mason, Michael D
2015-01-27
Understanding surface and interfacial lateral organization in material and biological systems is critical in nearly every field of science. The continued development of tools and techniques viable for elucidation of interfacial and surface information is therefore necessary to address new questions and further current investigations. Sum frequency spectroscopy (SFS) is a label-free, nonlinear optical technique with inherent surface specificity that can yield critical organizational information on interfacial species. Unfortunately, SFS provides no spatial information on a surface; small scale heterogeneities that may exist are averaged over the large areas typically probed. Over the past decade, this has begun to be addressed with the advent of SFS microscopy. Here we detail the construction and function of a total internal reflection (TIR) SFS spectral and confocal fluorescence imaging microscope directly amenable to surface investigations. This instrument combines, for the first time, sample scanning TIR-SFS imaging with confocal fluorescence microscopy.
NASA Astrophysics Data System (ADS)
Heise, H. M.; Fritzsche, J.; Tkatsch, H.; Waag, F.; Karch, K.; Henze, K.; Delbeck, S.; Budde, J.
2013-11-01
Mid- and near-infrared spectroscopy is introduced as a versatile analytical method for characterizing liquid and solid chemicals as obtained from petrochemistry and biotechnology processes. Besides normal transmission measurements, special equipment with silver halide fiber-optic probes allowing efficient analysis based on mid-infrared attenuated total reflection, and an accessory for near-infrared diffuse reflection measurements, are presented. The latter technique can be used advantageously for powdered samples such as microalgae biomass and polysaccharides, as well as for different tissues such as meat samples. The advantages and disadvantages of both methods, which can be used for industrial process monitoring and chemical quality control applications, are discussed, and have been used in several research projects of BSc students within their degree course of bio- and nano-technologies of our University of Applied Sciences.
NASA Astrophysics Data System (ADS)
Chen, Hua-cai; Chen, Xing-dan; Lu, Yong-jun; Cao, Zhi-qiang
2006-01-01
Near infrared (NIR) reflectance spectroscopy was used to develop a fast determination method for total ginsenosides in Ginseng (Panax Ginseng) powder. The spectra were analyzed with multiplicative signal correction (MSC) correlation method. The best correlative spectra region with the total ginsenosides content was 1660 nm~1880 nm and 2230nm~2380 nm. The NIR calibration models of ginsenosides were built with multiple linear regression (MLR), principle component regression (PCR) and partial least squares (PLS) regression respectively. The results showed that the calibration model built with PLS combined with MSC and the optimal spectrum region was the best one. The correlation coefficient and the root mean square error of correction validation (RMSEC) of the best calibration model were 0.98 and 0.15% respectively. The optimal spectrum region for calibration was 1204nm~2014nm. The result suggested that using NIR to rapidly determinate the total ginsenosides content in ginseng powder were feasible.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Watanabe, Yoshihide, E-mail: e0827@mosk.tytlabs.co.jp; Nishimura, Yusaku F.; Suzuki, Ryo
A portable ultrahigh-vacuum sample storage system was designed and built to investigate the detailed geometric structures of mass-selected metal clusters on oxide substrates by polarization-dependent total-reflection fluorescence x-ray absorption fine structure spectroscopy (PTRF-XAFS). This ultrahigh-vacuum (UHV) sample storage system provides the handover of samples between two different sample manipulating systems. The sample storage system is adaptable for public transportation, facilitating experiments using air-sensitive samples in synchrotron radiation or other quantum beam facilities. The samples were transferred by the developed portable UHV transfer system via a public transportation at a distance over 400 km. The performance of the transfer system was demonstratedmore » by a successful PTRF-XAFS study of Pt{sub 4} clusters deposited on a TiO{sub 2}(110) surface.« less